Sample records for quality control application

  1. Mindcontrol: A web application for brain segmentation quality control.

    PubMed

    Keshavan, Anisha; Datta, Esha; M McDonough, Ian; Madan, Christopher R; Jordan, Kesshi; Henry, Roland G

    2018-04-15

    Tissue classification plays a crucial role in the investigation of normal neural development, brain-behavior relationships, and the disease mechanisms of many psychiatric and neurological illnesses. Ensuring the accuracy of tissue classification is important for quality research and, in particular, the translation of imaging biomarkers to clinical practice. Assessment with the human eye is vital to correct various errors inherent to all currently available segmentation algorithms. Manual quality assurance becomes methodologically difficult at a large scale - a problem of increasing importance as the number of data sets is on the rise. To make this process more efficient, we have developed Mindcontrol, an open-source web application for the collaborative quality control of neuroimaging processing outputs. The Mindcontrol platform consists of a dashboard to organize data, descriptive visualizations to explore the data, an imaging viewer, and an in-browser annotation and editing toolbox for data curation and quality control. Mindcontrol is flexible and can be configured for the outputs of any software package in any data organization structure. Example configurations for three large, open-source datasets are presented: the 1000 Functional Connectomes Project (FCP), the Consortium for Reliability and Reproducibility (CoRR), and the Autism Brain Imaging Data Exchange (ABIDE) Collection. These demo applications link descriptive quality control metrics, regional brain volumes, and thickness scalars to a 3D imaging viewer and editing module, resulting in an easy-to-implement quality control protocol that can be scaled for any size and complexity of study. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  2. A real time quality control application for animal production by image processing.

    PubMed

    Sungur, Cemil; Özkan, Halil

    2015-11-01

    Standards of hygiene and health are of major importance in food production, and quality control has become obligatory in this field. Thanks to rapidly developing technologies, it is now possible for automatic and safe quality control of food production. For this purpose, image-processing-based quality control systems used in industrial applications are being employed to analyze the quality of food products. In this study, quality control of chicken (Gallus domesticus) eggs was achieved using a real time image-processing technique. In order to execute the quality control processes, a conveying mechanism was used. Eggs passing on a conveyor belt were continuously photographed in real time by cameras located above the belt. The images obtained were processed by various methods and techniques. Using digital instrumentation, the volume of the eggs was measured, broken/cracked eggs were separated and dirty eggs were determined. In accordance with international standards for classifying the quality of eggs, the class of separated eggs was determined through a fuzzy implication model. According to tests carried out on thousands of eggs, a quality control process with an accuracy of 98% was possible. © 2014 Society of Chemical Industry.

  3. [Application of traditional Chinese medicine reference standards in quality control of Chinese herbal pieces].

    PubMed

    Lu, Tu-Lin; Li, Jin-Ci; Yu, Jiang-Yong; Cai, Bao-Chang; Mao, Chun-Qin; Yin, Fang-Zhou

    2014-01-01

    Traditional Chinese medicine (TCM) reference standards plays an important role in the quality control of Chinese herbal pieces. This paper overviewed the development of TCM reference standards. By analyzing the 2010 edition of Chinese pharmacopoeia, the application of TCM reference standards in the quality control of Chinese herbal pieces was summarized, and the problems exiting in the system were put forward. In the process of improving the quality control level of Chinese herbal pieces, various kinds of advanced methods and technology should be used to research the characteristic reference standards of Chinese herbal pieces, more and more reasonable reference standards should be introduced in the quality control system of Chinese herbal pieces. This article discussed the solutions in the aspect of TCM reference standards, and future development of quality control on Chinese herbal pieces is prospected.

  4. [Application of fingerprint chromatogram in quality control of Shen-Mai injection].

    PubMed

    Shi, Xian-zhe; Yang, Jun; Zhao, Chun-xia; Xiong, Jian-hui; Xu, Guo-wang

    2002-07-01

    The theory and practice of traditional Chinese medicine require some comprehensive methods to assess quality of the Chinese herbal medication. Fingerprint chromatogram is one of the feasible approaches to evaluate the quality of Chinese herbal medication. So the fingerprint chromatogram of Shen-Mai injection was established by using reversed-phase high performance liquid chromatography. The chromatographic conditions were as follows: a Hypersil C18 column was used; the mobile phase was composed of water (A) and acetontrile (B) with linear gradient elution (0-50 min, 5%-95% B, volume fraction); the flow rate was 1.0 mL/min and the UV absorbance detection was set at 202 nm. The peak-area ratios of twenty-three fingerprint peaks and internal standard (diphenyl) were taken as the criteria for quality control. The quality differences in various batches and various manufacturers of Shen-Mai injections were investigated by projection discriminance based on principal component analysis. The results show the method developed is convenient, reliable and applicable for the quality control analysis of Shen-Mai injection.

  5. Random Forest Application for NEXRAD Radar Data Quality Control

    NASA Astrophysics Data System (ADS)

    Keem, M.; Seo, B. C.; Krajewski, W. F.

    2017-12-01

    Identification and elimination of non-meteorological radar echoes (e.g., returns from ground, wind turbines, and biological targets) are the basic data quality control steps before radar data use in quantitative applications (e.g., precipitation estimation). Although WSR-88Ds' recent upgrade to dual-polarization has enhanced this quality control and echo classification, there are still challenges to detect some non-meteorological echoes that show precipitation-like characteristics (e.g., wind turbine or anomalous propagation clutter embedded in rain). With this in mind, a new quality control method using Random Forest is proposed in this study. This classification algorithm is known to produce reliable results with less uncertainty. The method introduces randomness into sampling and feature selections and integrates consequent multiple decision trees. The multidimensional structure of the trees can characterize the statistical interactions of involved multiple features in complex situations. The authors explore the performance of Random Forest method for NEXRAD radar data quality control. Training datasets are selected using several clear cases of precipitation and non-precipitation (but with some non-meteorological echoes). The model is structured using available candidate features (from the NEXRAD data) such as horizontal reflectivity, differential reflectivity, differential phase shift, copolar correlation coefficient, and their horizontal textures (e.g., local standard deviation). The influence of each feature on classification results are quantified by variable importance measures that are automatically estimated by the Random Forest algorithm. Therefore, the number and types of features in the final forest can be examined based on the classification accuracy. The authors demonstrate the capability of the proposed approach using several cases ranging from distinct to complex rain/no-rain events and compare the performance with the existing algorithms (e

  6. 40 CFR 136.7 - Quality assurance and quality control.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... quality control elements, where applicable, into the laboratory's documented standard operating procedure... quality control elements must be clearly documented in the written standard operating procedure for each... Methods contains QA/QC procedures in the Part 1000 section of the Standard Methods Compendium. The...

  7. 40 CFR 136.7 - Quality assurance and quality control.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... quality control elements, where applicable, into the laboratory's documented standard operating procedure... quality control elements must be clearly documented in the written standard operating procedure for each... Methods contains QA/QC procedures in the Part 1000 section of the Standard Methods Compendium. The...

  8. 40 CFR 136.7 - Quality assurance and quality control.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... quality control elements, where applicable, into the laboratory's documented standard operating procedure... quality control elements must be clearly documented in the written standard operating procedure for each... Methods contains QA/QC procedures in the Part 1000 section of the Standard Methods Compendium. The...

  9. 14 CFR 21.139 - Quality control.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Quality control. 21.139 Section 21.139... PROCEDURES FOR PRODUCTS AND PARTS Production Certificates § 21.139 Quality control. The applicant must show that he has established and can maintain a quality control system for any product, for which he...

  10. 33 CFR 385.21 - Quality control.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 3 2011-07-01 2011-07-01 false Quality control. 385.21 Section... Processes § 385.21 Quality control. (a) The Corps of Engineers and the non-Federal sponsor shall prepare a quality control plan, in accordance with applicable Corps of Engineers regulations, for each product that...

  11. 14 CFR 21.139 - Quality control.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Quality control. 21.139 Section 21.139... PROCEDURES FOR PRODUCTS AND PARTS Production Certificates § 21.139 Quality control. The applicant must show that he has established and can maintain a quality control system for any product, for which he...

  12. 33 CFR 385.21 - Quality control.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 3 2013-07-01 2013-07-01 false Quality control. 385.21 Section... Processes § 385.21 Quality control. (a) The Corps of Engineers and the non-Federal sponsor shall prepare a quality control plan, in accordance with applicable Corps of Engineers regulations, for each product that...

  13. 33 CFR 385.21 - Quality control.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Quality control. 385.21 Section... Processes § 385.21 Quality control. (a) The Corps of Engineers and the non-Federal sponsor shall prepare a quality control plan, in accordance with applicable Corps of Engineers regulations, for each product that...

  14. [Application progress on near infrared spectroscopy in quality control and process monitoring of traditional Chinese medicine].

    PubMed

    Li, Wenlong; Qu, Haibin

    2017-01-25

    The industry of traditional Chinese medicine (TCM) encounters problems like quality fluctuation of raw materials and unstandardized production process. Near infrared (NIR) spectroscopy technology is widely used in quality control of TCM because of its abundant information, fast and nondestructive characters. The main applications include quantitative analysis of Chinese medicinal materials, intermediates and Chinese patent medicines; the authenticity of TCM, species, origins and manufacturers; monitoring and control of the extraction, alcohol precipitation, column chromatography and blending process. This article reviews the progress on the application of NIR spectroscopy technology in TCM field. In view of the problems existing in the application, the article proposes that the standardization of NIR analysis method should be developed according to specific characteristics of TCM, which will promote the application of NIR technology in the TCM industry.

  15. 18 CFR 12.40 - Quality control programs.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false Quality control... PROJECT WORKS Other Responsibilities of Applicant or Licensee § 12.40 Quality control programs. (a... meeting any requirements or standards set by the Regional Engineer. If a quality control program is...

  16. 18 CFR 12.40 - Quality control programs.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Quality control... PROJECT WORKS Other Responsibilities of Applicant or Licensee § 12.40 Quality control programs. (a... meeting any requirements or standards set by the Regional Engineer. If a quality control program is...

  17. [Application of microscopic spectroscopy in quality control of Niuhuang Qingxin pills].

    PubMed

    Nie, Li-Xing; Zhang, Ye; Zhang, Nan-Ping; Hu, Xiao-Ru; Kang, Shuai; Hou, Jian-Zhong; Dai, Zhong; Ma, Shuang-Cheng

    2016-10-01

    Application of microscopic spectroscopy in quality control of Niuhuang Qingxin pills was discussed. First, microscopic characteristics specified by the statutory standard of Niuhuang Qingxin pills were summarized. Then new identification method was established for Dioscoreae Rhizoma, Saigae Tataricae Cornu, Cinnamomi Cortex and Saposhnikoviae Radix. Finally, microscopic spectroscopy was used for test of Dioscoreae Rhizoma's adulterant Dioscoreae Fordii Rhizoma.It was the first time for this technology being applied in adulteration test of Chinese patent medicine.The results showed that Saigae Tataricae Cornu was not detected in 2 batches of Niuhuang Qingxin pills from 1 manufacturer while Dioscoreae Fordii Rhizoma was detected in 3 batches of samples from 2 manufacturers. The proposed methods were accurate, simple, rapid, objective and economic, which offered a more comprehensive approach for quality control of Niuhuang Qingxin pills. It was indicated that conventional technology such as microscopic spectroscopy could play an important role in identification of traditional Chinese medicine whose index ingredient was deficient or tiny. Copyright© by the Chinese Pharmaceutical Association.

  18. 30 CFR 74.6 - Quality control.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Quality control. 74.6 Section 74.6 Mineral... control. The applicant shall describe the way in which each lot of components will be sampled and tested... of the CMDPSU will be maintained in production through adequate quality control procedures, MSHA and...

  19. 30 CFR 74.6 - Quality control.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Quality control. 74.6 Section 74.6 Mineral... control. The applicant shall describe the way in which each lot of components will be sampled and tested... of the CMDPSU will be maintained in production through adequate quality control procedures, MSHA and...

  20. 30 CFR 74.6 - Quality control.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Quality control. 74.6 Section 74.6 Mineral... control. The applicant shall describe the way in which each lot of components will be sampled and tested... of the CMDPSU will be maintained in production through adequate quality control procedures, MSHA and...

  1. [Feedforward control strategy and its application in quality improvement of ethanol precipitation process of danhong injection].

    PubMed

    Yan, Bin-Jun; Guo, Zheng-Tai; Qu, Hai-Bin; Zhao, Bu-Chang; Zhao, Tao

    2013-06-01

    In this work, a feedforward control strategy basing on the concept of quality by design was established for the manufacturing process of traditional Chinese medicine to reduce the impact of the quality variation of raw materials on drug. In the research, the ethanol precipitation process of Danhong injection was taken as an application case of the method established. Box-Behnken design of experiments was conducted. Mathematical models relating the attributes of the concentrate, the process parameters and the quality of the supernatants produced were established. Then an optimization model for calculating the best process parameters basing on the attributes of the concentrate was built. The quality of the supernatants produced by ethanol precipitation with optimized and non-optimized process parameters were compared. The results showed that using the feedforward control strategy for process parameters optimization can control the quality of the supernatants effectively. The feedforward control strategy proposed can enhance the batch-to-batch consistency of the supernatants produced by ethanol precipitation.

  2. Quality control in gastrointestinal surgery.

    PubMed

    Ramírez-Barba, Ector Jaime; Arenas-Moya, Diego; Vázquez-Guerrero, Arturo

    2011-01-01

    We analyzed the Mexican legal framework, identifying the vectors that characterize quality and control in gastrointestinal surgery. Quality is contemplated in the health protection rights determined according to the Mexican Constitution, established in the general health law and included as a specific goal in the actual National Development Plan and Health Sector Plan. Quality control implies planning, verification and application of corrective measures. Mexico has implemented several quality strategies such as certification of hospitals and regulatory agreements by the General Salubrity Council, creation of the National Health Quality Committee, generation of Clinical Practice Guidelines and the Certification of Medical Specialties, among others. Quality control in gastrointestinal surgery must begin at the time of medical education and continue during professional activities of surgeons, encouraging multidisciplinary teamwork, knowledge, abilities, attitudes, values and skills that promote homogeneous, safe and quality health services for the Mexican population.

  3. [Quality control in herbal supplements].

    PubMed

    Oelker, Luisa

    2005-01-01

    Quality and safety of food and herbal supplements are the result of a whole of different elements as good manufacturing practice and process control. The process control must be active and able to individuate and correct all possible hazards. The main and most utilized instrument is the hazard analysis critical control point (HACCP) system the correct application of which can guarantee the safety of the product. Herbal supplements need, in addition to standard quality control, a set of checks to assure the harmlessness and safety of the plants used.

  4. 30 CFR 28.30 - Quality control plans; filing requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Quality control plans; filing requirements. 28... PROTECTION FOR TRAILING CABLES IN COAL MINES Quality Control § 28.30 Quality control plans; filing... part, each applicant shall file with MSHA a proposed quality control plan which shall be designed to...

  5. 30 CFR 28.30 - Quality control plans; filing requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality control plans; filing requirements. 28... PROTECTION FOR TRAILING CABLES IN COAL MINES Quality Control § 28.30 Quality control plans; filing... part, each applicant shall file with MSHA a proposed quality control plan which shall be designed to...

  6. 30 CFR 28.30 - Quality control plans; filing requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PROTECTION FOR TRAILING CABLES IN COAL MINES Quality Control § 28.30 Quality control plans; filing... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Quality control plans; filing requirements. 28... part, each applicant shall file with MSHA a proposed quality control plan which shall be designed to...

  7. 30 CFR 28.30 - Quality control plans; filing requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... PROTECTION FOR TRAILING CABLES IN COAL MINES Quality Control § 28.30 Quality control plans; filing... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Quality control plans; filing requirements. 28... part, each applicant shall file with MSHA a proposed quality control plan which shall be designed to...

  8. 30 CFR 28.30 - Quality control plans; filing requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PROTECTION FOR TRAILING CABLES IN COAL MINES Quality Control § 28.30 Quality control plans; filing... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Quality control plans; filing requirements. 28... part, each applicant shall file with MSHA a proposed quality control plan which shall be designed to...

  9. 18 CFR 12.40 - Quality control programs.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... PROJECT WORKS Other Responsibilities of Applicant or Licensee § 12.40 Quality control programs. (a) General rule. During any construction, repair, or modification of project works, including any corrective... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Quality control...

  10. 18 CFR 12.40 - Quality control programs.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... PROJECT WORKS Other Responsibilities of Applicant or Licensee § 12.40 Quality control programs. (a) General rule. During any construction, repair, or modification of project works, including any corrective... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Quality control...

  11. 18 CFR 12.40 - Quality control programs.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... PROJECT WORKS Other Responsibilities of Applicant or Licensee § 12.40 Quality control programs. (a) General rule. During any construction, repair, or modification of project works, including any corrective... 18 Conservation of Power and Water Resources 1 2012-04-01 2012-04-01 false Quality control...

  12. Application of miniaturized near-infrared spectroscopy for quality control of extemporaneous orodispersible films.

    PubMed

    Foo, Wen Chin; Widjaja, Effendi; Khong, Yuet Mei; Gokhale, Rajeev; Chan, Sui Yung

    2018-02-20

    Extemporaneous oral preparations are routinely compounded in the pharmacy due to a lack of suitable formulations for special populations. Such small-scale pharmacy preparations also present an avenue for individualized pharmacotherapy. Orodispersible films (ODF) have increasingly been evaluated as a suitable dosage form for extemporaneous oral preparations. Nevertheless, as with all other extemporaneous preparations, safety and quality remain a concern. Although the United States Pharmacopeia (USP) recommends analytical testing of compounded preparations for quality assurance, pharmaceutical assays are typically not routinely performed for such non-sterile pharmacy preparations, due to the complexity and high cost of conventional assay methods such as high performance liquid chromatography (HPLC). Spectroscopic methods including Raman, infrared and near-infrared spectroscopy have been successfully applied as quality control tools in the industry. The state-of-art benchtop spectrometers used in those studies have the advantage of superior resolution and performance, but are not suitable for use in a small-scale pharmacy setting. In this study, we investigated the application of a miniaturized near infrared (NIR) spectrometer as a quality control tool for identification and quantification of drug content in extemporaneous ODFs. Miniaturized near infrared (NIR) spectroscopy is suitable for small-scale pharmacy applications in view of its small size, portability, simple user interface, rapid measurement and real-time prediction results. Nevertheless, the challenge with miniaturized NIR spectroscopy is its lower resolution compared to state-of-art benchtop equipment. We have successfully developed NIR spectroscopy calibration models for identification of ODFs containing five different drugs, and quantification of drug content in ODFs containing 2-10mg ondansetron (OND). The qualitative model for drug identification produced 100% prediction accuracy. The quantitative

  13. Colorado Air Quality Control Regulations and Ambient Air Quality Standards.

    ERIC Educational Resources Information Center

    Colorado State Dept. of Health, Denver. Div. of Air Pollution Control.

    Regulations and standards relative to air quality control in Colorado are defined in this publication. Presented first are definitions of terms, a statement of intent, and general provisions applicable to all emission control regulations adopted by the Colorado Air Pollution Control Commission. Following this, three regulations are enumerated: (1)…

  14. Multi-application controls: Robust nonlinear multivariable aerospace controls applications

    NASA Technical Reports Server (NTRS)

    Enns, Dale F.; Bugajski, Daniel J.; Carter, John; Antoniewicz, Bob

    1994-01-01

    This viewgraph presentation describes the general methodology used to apply Honywell's Multi-Application Control (MACH) and the specific application to the F-18 High Angle-of-Attack Research Vehicle (HARV) including piloted simulation handling qualities evaluation. The general steps include insertion of modeling data for geometry and mass properties, aerodynamics, propulsion data and assumptions, requirements and specifications, e.g. definition of control variables, handling qualities, stability margins and statements for bandwidth, control power, priorities, position and rate limits. The specific steps include choice of independent variables for least squares fits to aerodynamic and propulsion data, modifications to the management of the controls with regard to integrator windup and actuation limiting and priorities, e.g. pitch priority over roll, and command limiting to prevent departures and/or undesirable inertial coupling or inability to recover to a stable trim condition. The HARV control problem is characterized by significant nonlinearities and multivariable interactions in the low speed, high angle-of-attack, high angular rate flight regime. Systematic approaches to the control of vehicle motions modeled with coupled nonlinear equations of motion have been developed. This paper will discuss the dynamic inversion approach which explicity accounts for nonlinearities in the control design. Multiple control effectors (including aerodynamic control surfaces and thrust vectoring control) and sensors are used to control the motions of the vehicles in several degrees-of-freedom. Several maneuvers will be used to illustrate performance of MACH in the high angle-of-attack flight regime. Analytical methods for assessing the robust performance of the multivariable control system in the presence of math modeling uncertainty, disturbances, and commands have reached a high level of maturity. The structured singular value (mu) frequency response methodology is presented

  15. [Application of bioassay in quality control of Chinese materia medica-taking Radix Isatidis as an example].

    PubMed

    Yan, Dan; Ren, Yongshen; Luo, Jiaoyang; Li, Hanbing; Feng, Xue; Xiao, Xiaohe

    2010-10-01

    Bioassay, which construct the characteristics consistents with Chinese medical science, is the core mode and methods for the quality control of Chinese materia medica. Taking the bioassay of Radix Isatidis as an example, the contribution, status and application of bioassay in the quality control of Chinese materia medica were introduced in this article, and two key issue (the selection of reference and measurement methods) in the process of establishing bioassay were also explained. This article expects to provide a reference for the development and improvement of the bioassay of Chinese materia medica in a practical manipulation level.

  16. [Post-marketing reevaluation for potential quality risk and quality control in clinical application of traditional Chinese medicines].

    PubMed

    Li, Hong-jiao; He, Li-yun; Liu, Bao-yan

    2015-06-01

    The effective quality control in clinical practices is an effective guarantee for the authenticity and scientificity of the findings. The post-marketing reevaluation for traditional Chinese medicines (TCM) focuses on the efficacy, adverse reaction, combined medication and effective dose of drugs in the market by expanded clinical trials, and requires a larger sample size and a wider range of patients. Therefore, this increases the difficulty of quality control in clinical practices. With the experience in quality control in clinical practices for the post-marketing reevaluation for Kangbingdu oral for cold, researchers in this study reviewed the study purpose, project, scheme design and clinical practice process from an overall point of view, analyzed the study characteristics of the post-marketing reevaluation for TCMs and the quality control risks, designed the quality control contents with quality impacting factors, defined key review contents and summarized the precautions in clinical practices, with the aim to improve the efficiency of quality control of clinical practices. This study can provide reference to clinical units and quality control-related personnel in the post-marketing reevaluation for TCMs.

  17. HANDBOOK: QUALITY ASSURANCE/QUALITY CONTROL (QA/QC) PROCEDURES FOR HAZARDOUS WASTE INCINERATION

    EPA Science Inventory

    Resource Conservation and Recovery Act regulations for hazardous waste incineration require trial burns by permit applicants. uality Assurance Project Plan (QAPjP) must accompany a trial burn plan with appropriate quality assurance/quality control procedures. uidance on the prepa...

  18. Quality by control: Towards model predictive control of mammalian cell culture bioprocesses.

    PubMed

    Sommeregger, Wolfgang; Sissolak, Bernhard; Kandra, Kulwant; von Stosch, Moritz; Mayer, Martin; Striedner, Gerald

    2017-07-01

    The industrial production of complex biopharmaceuticals using recombinant mammalian cell lines is still mainly built on a quality by testing approach, which is represented by fixed process conditions and extensive testing of the end-product. In 2004 the FDA launched the process analytical technology initiative, aiming to guide the industry towards advanced process monitoring and better understanding of how critical process parameters affect the critical quality attributes. Implementation of process analytical technology into the bio-production process enables moving from the quality by testing to a more flexible quality by design approach. The application of advanced sensor systems in combination with mathematical modelling techniques offers enhanced process understanding, allows on-line prediction of critical quality attributes and subsequently real-time product quality control. In this review opportunities and unsolved issues on the road to a successful quality by design and dynamic control implementation are discussed. A major focus is directed on the preconditions for the application of model predictive control for mammalian cell culture bioprocesses. Design of experiments providing information about the process dynamics upon parameter change, dynamic process models, on-line process state predictions and powerful software environments seem to be a prerequisite for quality by control realization. © 2017 The Authors. Biotechnology Journal published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. A Resampling Analysis of Federal Family Assistance Program Quality Control Data: An Application of the Bootstrap.

    ERIC Educational Resources Information Center

    Hand, Michael L.

    1990-01-01

    Use of the bootstrap resampling technique (BRT) is assessed in its application to resampling analysis associated with measurement of payment allocation errors by federally funded Family Assistance Programs. The BRT is applied to a food stamp quality control database in Oregon. This analysis highlights the outlier-sensitivity of the…

  20. Quality control of colonoscopy procedures: a prospective validated method for the evaluation of professional practices applicable to all endoscopic units.

    PubMed

    Coriat, R; Pommaret, E; Chryssostalis, A; Viennot, S; Gaudric, M; Brezault, C; Lamarque, D; Roche, H; Verdier, D; Parlier, D; Prat, F; Chaussade, S

    2009-02-01

    To produce valid information, an evaluation of professional practices has to assess the quality of all practices before, during and after the procedure under study. Several auditing techniques have been proposed for colonoscopy. The purpose of this work is to describe a straightforward original validated method for the prospective evaluation of professional practices in the field of colonoscopy applicable in all endoscopy units without increasing the staff work load. Pertinent quality-control criteria (14 items) were identified by the endoscopists at the Cochin Hospital and were compatible with: findings in the available literature; guidelines proposed by the Superior Health Authority; and application in any endoscopy unit. Prospective routine data were collected and the methodology validated by evaluating 50 colonoscopies every quarter for one year. The relevance of the criteria was assessed using data collected during four separate periods. The standard checklist was complete for 57% of the colonoscopy procedures. The colonoscopy procedure was appropriate according to national guidelines in 94% of cases. These observations were particularly noteworthy: the quality of the colonic preparation was insufficient for 9% of the procedures; complete colonoscopy was achieved for 93% of patients; and 0.38 adenomas and 0.045 carcinomas were identified per colonoscopy. This simple and reproducible method can be used for valid quality-control audits in all endoscopy units. In France, unit-wide application of this method enables endoscopists to validate 100 of the 250 points required for continuous medical training. This is a quality-control tool that can be applied annually, using a random month to evaluate any changes in routine practices.

  1. [Establishment and application of "multi-dimensional structure and process dynamic quality control technology system" in preparation products of traditional Chinese medicine (I)].

    PubMed

    Gu, Jun-Fei; Feng, Liang; Zhang, Ming-Hua; Wu, Chan; Jia, Xiao-Bin

    2013-11-01

    Safety is an important component of the quality control of traditional Chinese medicine (TCM) preparation products, as well as an important guarantee for clinical application. Currently, the quality control of TCMs in Chinese Pharmacopoeia mostly focuses on indicative compounds for TCM efficacy. TCM preparations are associated with multiple links, from raw materials to products, and each procedure may have impacts on the safety of preparation. We make a summary and analysis on the factors impacting safety during the preparation of TCM products, and then expound the important role of the "multi-dimensional structure and process dynamic quality control technology system" in the quality safety of TCM preparations. Because the product quality of TCM preparation is closely related to the safety, the control over safety-related material basis is an important component of the product quality control of TCM preparations. The implementation of the quality control over the dynamic process of TCM preparations from raw materials to products, and the improvement of the TCM quality safety control at the microcosmic level help lay a firm foundation for the development of the modernization process of TCM preparations.

  2. Application of a sub-specialties management model improves quality control in a central sterile supply department.

    PubMed

    Wang, Li; Cai, Xuejiao; Cheng, Ping

    2018-05-30

    The management of medical devices is crucial to safe, high-quality surgical care, but has received little attention in the medical literature. This study explored the effect of a sub-specialties management model in the Central Sterile Supply Department (CSSD). A traditional routine management model (control) was applied from September 2015 through April 2016, and a newly developed sub-specialties management model (observation) was applied from July 2016 through February 2017. Health personnel from various clinical departments were randomly selected to participate as the control (n = 86) and observation (n = 90) groups, respectively. The groups were compared for rates of personnel satisfaction, complaints regarding device errors, and damage of medical devices. The satisfaction score of the observation group (95.8 ± 1.2) was significantly higher than that of the control (90.2 ± 2.3; P = 0.000). The rate of complaints of the observation group (3.3%) was significantly lower than that of the control (11.6%; P = 0.035). The quality control regarding recycle and packing was significantly higher during the observation period than the control period, which favorably influenced the scores for satisfaction. The rate of damage to specialist medical devices during the observation period (0.40%) was lower than during the control period (0.61%; P = 0.003). The theoretical knowledge and practical skills of the CSSD professionals improved after application of the sub-specialties management model. A management model that considers the requirements of specialist medical devices can improve quality control in the CSSD.

  3. Application of control theory to dynamic systems simulation

    NASA Technical Reports Server (NTRS)

    Auslander, D. M.; Spear, R. C.; Young, G. E.

    1982-01-01

    The application of control theory is applied to dynamic systems simulation. Theory and methodology applicable to controlled ecological life support systems are considered. Spatial effects on system stability, design of control systems with uncertain parameters, and an interactive computing language (PARASOL-II) designed for dynamic system simulation, report quality graphics, data acquisition, and simple real time control are discussed.

  4. [Application of THz technology to nondestructive detection of agricultural product quality].

    PubMed

    Jiang, Yu-ying; Ge, Hong-yi; Lian, Fei-yu; Zhang, Yuan; Xia, Shan-hong

    2014-08-01

    With recent development of THz sources and detector, applications of THz radiation to nondestructive testing and quality control have expanded in many fields, such as agriculture, safety inspection and quality control, medicine, biochemistry, communication etc. Compared with other detection technique, being a new kind of technique, THz radiation has low energy, good perspectivity, and high signal-to-noise ratio, and thus can obtain physical, chemical and biological information. This paper first introduces the basic concept of THz radiation and the major properties, then gives an extensive review of recent research progress in detection of the quality of agricultural products via THz technique, analyzes the existing shortcomings of THz detection and discusses the outlook of potential application, finally proposes the new application of THz technique to detection of quality of stored grain.

  5. Control by quality: proposition of a typology.

    PubMed

    Pujo, P; Pillet, M

    The application of Quality tools and methods in industrial management has always had a fundamental impact on the control of production. It influences the behavior of the actors concerned, while introducing the necessary notions and formalizations, especially for production systems with little or no automation, which constitute a large part of the industrial activity. Several quality approaches are applied in the workshop and are implemented at the level of the control. In this paper, the authors present a typology of the various approaches that have successively influenced control, such as statistical process control, quality assurance, and continuous improvement. First the authors present a parallel between production control and quality organizational structure. They note the duality between control, which is aimed at increasing productivity, and quality, which aims to satisfy the needs of the customer. They also note the hierarchical organizational structure of these two systems of management with, at each level, the notion of a feedback loop. This notion is fundamental to any kind of decision making. The paper is organized around the operational, tactical, and strategic levels, by describing for each level the main methods and tools for control by quality. The overview of these tools and methods starts at the operational level, with the Statistical Process Control, the Taguchi technique, and the "six sigma" approach. On the tactical level, we find a quality system approach, with a documented description of the procedures introduced in the firm. The management system can refer here to Quality Assurance, Total Productive Maintenance, or Management by Total Quality. The formalization through procedures of the rules of decision governing the process control enhances the validity of these rules. This leads to the enhancement of their reliability and to their consolidation. All this counterbalances the human, intrinsically fluctuating, behavior of the control

  6. Quality Control of the Print with the Application of Statistical Methods

    NASA Astrophysics Data System (ADS)

    Simonenko, K. V.; Bulatova, G. S.; Antropova, L. B.; Varepo, L. G.

    2018-04-01

    The basis for standardizing the process of offset printing is the control of print quality indicators. The solution of this problem has various approaches, among which the most important are statistical methods. Practical implementation of them for managing the quality of the printing process is very relevant and is reflected in this paper. The possibility of using the method of constructing a Control Card to identify the reasons for the deviation of the optical density for a triad of inks in offset printing is shown.

  7. [Quality process control system of Chinese medicine preparation based on "holistic view"].

    PubMed

    Wang, Ya-Qi; Jiao, Jiao-Jiao; Wu, Zhen-Feng; Zheng, Qin; Yang, Ming

    2018-01-01

    "High quality, safety and effectiveness" are the primary principles for the pharmaceutical research and development process in China. The quality of products relies not only on the inspection method, but also on the design and development, process control and standardized management. The quality depends on the process control level. In this paper, the history and current development of quality control of traditional Chinese medicine (TCM) preparations are reviewed systematically. Based on the development model of international drug quality control and the misunderstanding of quality control of TCM preparations, the reasons for impacting the homogeneity of TCM preparations are analyzed and summarized. According to TCM characteristics, efforts were made to control the diversity of TCM, make "unstable" TCM into "stable" Chinese patent medicines, put forward the concepts of "holistic view" and "QbD (quality by design)", so as to create the "holistic, modular, data, standardized" model as the core of TCM preparation quality process control model. Scientific studies shall conform to the actual production of TCM preparations, and be conducive to supporting advanced equipment and technology upgrade, thoroughly applying the scientific research achievements in Chinese patent medicines, and promoting the cluster application and transformation application of TCM pharmaceutical technology, so as to improve the quality and effectiveness of the TCM industry and realize the green development. Copyright© by the Chinese Pharmaceutical Association.

  8. Mesh quality control for multiply-refined tetrahedral grids

    NASA Technical Reports Server (NTRS)

    Biswas, Rupak; Strawn, Roger

    1994-01-01

    A new algorithm for controlling the quality of multiply-refined tetrahedral meshes is presented in this paper. The basic dynamic mesh adaption procedure allows localized grid refinement and coarsening to efficiently capture aerodynamic flow features in computational fluid dynamics problems; however, repeated application of the procedure may significantly deteriorate the quality of the mesh. Results presented show the effectiveness of this mesh quality algorithm and its potential in the area of helicopter aerodynamics and acoustics.

  9. The Effects of a Mobile Phone Application on Quality of Life in Patients With Type 1 Diabetes Mellitus: A Randomized Controlled Trial.

    PubMed

    Drion, Iefke; Pameijer, Loes R; van Dijk, Peter R; Groenier, Klaas H; Kleefstra, Nanne; Bilo, Henk J G

    2015-05-11

    The combination of an increasing prevalence of diabetes mellitus and more people having access to smartphones creates opportunities for patient care. This study aims to investigate whether the use of the Diabetes Under Control (DBEES) mobile phone application, a digital diabetes diary, results in a change in quality of life for patients with type 1 diabetes mellitus (T1DM) compared with the standard paper diary. In this randomized controlled open-label trial, 63 patients with T1DM having access to a smartphone were assigned to the intervention group using the DBEES application (n = 31) or the control group using the standard paper diary (n = 32). Primary outcome was the change in quality of life, as measured by the RAND-36 questionnaire, between both groups. Secondary outcomes included diabetes-related distress (PAID), HbA1c, frequency of self-monitoring blood glucose, and the usability of the diabetes application (SUS). Patients had a median age (IQR) of 33 (21) years, diabetes duration of 17 (16) years, and an HbA1c of 62 ± 16 mmol/mol. No significant differences in the QOL, using the RAND-36, within and between both groups were observed after 3 months. Glycemic control, diabetes-related emotional distress, and frequency of self-monitoring of blood glucose remained within and between groups. Users reviewed the usability of DBEES with a 72 ± 20, on a range of 0-100. The use of the DBEES application in the management of patients with T1DM for 3 months yields no alterations in quality of life compared to the standard paper diary. © 2015 Diabetes Technology Society.

  10. The consistency approach for quality control of vaccines - a strategy to improve quality control and implement 3Rs.

    PubMed

    De Mattia, Fabrizio; Chapsal, Jean-Michel; Descamps, Johan; Halder, Marlies; Jarrett, Nicholas; Kross, Imke; Mortiaux, Frederic; Ponsar, Cecile; Redhead, Keith; McKelvie, Jo; Hendriksen, Coenraad

    2011-01-01

    Current batch release testing of established vaccines emphasizes quality control of the final product and is often characterized by extensive use of animals. This report summarises the discussions of a joint ECVAM/EPAA workshop on the applicability of the consistency approach for routine release of human and veterinary vaccines and its potential to reduce animal use. The consistency approach is based upon thorough characterization of the vaccine during development and the principle that the quality of subsequent batches is the consequence of the strict application of a quality system and of a consistent production of batches. The concept of consistency of production is state-of-the-art for new-generation vaccines, where batch release is mainly based on non-animal methods. There is now the opportunity to introduce the approach into established vaccine production, where it has the potential to replace in vivo tests with non-animal tests designed to demonstrate batch quality while maintaining the highest quality standards. The report indicates how this approach may be further developed for application to established human and veterinary vaccines and emphasizes the continuing need for co-ordination and harmonization. It also gives recommendations for work to be undertaken in order to encourage acceptance and implementation of the consistency approach. Copyright © 2011. Published by Elsevier Ltd.. All rights reserved.

  11. Six Sigma Quality Management System and Design of Risk-based Statistical Quality Control.

    PubMed

    Westgard, James O; Westgard, Sten A

    2017-03-01

    Six sigma concepts provide a quality management system (QMS) with many useful tools for managing quality in medical laboratories. This Six Sigma QMS is driven by the quality required for the intended use of a test. The most useful form for this quality requirement is the allowable total error. Calculation of a sigma-metric provides the best predictor of risk for an analytical examination process, as well as a design parameter for selecting the statistical quality control (SQC) procedure necessary to detect medically important errors. Simple point estimates of sigma at medical decision concentrations are sufficient for laboratory applications. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. [The establishment and application of internal quality control system for real-time quantitative PCR detection of BCR-ABL (P210) transcript levels].

    PubMed

    Zhong, C Q; He, N; Hua, M Q; Wei, X D; Ma, D X; Ji, C Y

    2016-09-14

    results were reliable and stable. The application of quality control substance combined with slope rate and intercept in the internal quality control may contribute to quality assurance for quantitative detection of BCR-ABL (P210) transcript levels.

  13. Quality Leadership and Quality Control

    PubMed Central

    Badrick, Tony

    2003-01-01

    Different quality control rules detect different analytical errors with varying levels of efficiency depending on the type of error present, its prevalence and the number of observations. The efficiency of a rule can be gauged by inspection of a power function graph. Control rules are only part of a process and not an end in itself; just as important are the trouble-shooting systems employed when a failure occurs. 'Average of patient normals' may develop as a usual adjunct to conventional quality control serum based programmes. Acceptable error can be based on various criteria; biological variation is probably the most sensible. Once determined, acceptable error can be used as limits in quality control rule systems. A key aspect of an organisation is leadership, which links the various components of the quality system. Leadership is difficult to characterise but its key aspects include trust, setting an example, developing staff and critically setting the vision for the organisation. Organisations also have internal characteristics such as the degree of formalisation, centralisation, and complexity. Medical organisations can have internal tensions because of the dichotomy between the bureaucratic and the shadow medical structures. PMID:18568046

  14. Principles and Practices for Quality Assurance and Quality Control

    USGS Publications Warehouse

    Jones, Berwyn E.

    1999-01-01

    Quality assurance and quality control are vital parts of highway runoff water-quality monitoring projects. To be effective, project quality assurance must address all aspects of the project, including project management responsibilities and resources, data quality objectives, sampling and analysis plans, data-collection protocols, data quality-control plans, data-assessment procedures and requirements, and project outputs. Quality control ensures that the data quality objectives are achieved as planned. The historical development and current state of the art of quality assurance and quality control concepts described in this report can be applied to evaluation of data from prior projects.

  15. Outsourcing University Degrees: Implications for Quality Control

    ERIC Educational Resources Information Center

    Edwards, Julie; Crosling, Glenda; Edwards, Ron

    2010-01-01

    Education institutions worldwide have and continue to seek opportunities to spread their offerings abroad. While the provision of courses to students located overseas through partner institutions has many advantages, it raises questions about quality control that are not as applicable to other forms of international education. This paper uses a…

  16. Measuring management's perspective of data quality in Pakistan's Tuberculosis control programme: a test-based approach to identify data quality dimensions.

    PubMed

    Ali, Syed Mustafa; Anjum, Naveed; Kamel Boulos, Maged N; Ishaq, Muhammad; Aamir, Javariya; Haider, Ghulam Rasool

    2018-01-16

    Data quality is core theme of programme's performance assessment and many organizations do not have any data quality improvement strategy, wherein data quality dimensions and data quality assessment framework are important constituents. As there is limited published research about the data quality specifics that are relevant to the context of Pakistan's Tuberculosis control programme, this study aims at identifying the applicable data quality dimensions by using the 'fitness-for-purpose' perspective. Forty-two respondents pooled a total of 473 years of professional experience, out of which 223 years (47%) were in TB control related programmes. Based on the responses against 11 practical cases, adopted from the routine recording and reporting system of Pakistan's TB control programme (real identities of patient were masked), completeness, accuracy, consistency, vagueness, uniqueness and timeliness are the applicable data quality dimensions relevant to the programme's context, i.e. work settings and field of practice. Based on a 'fitness-for-purpose' approach to data quality, this study used a test-based approach to measure management's perspective and identified data quality dimensions pertinent to the programme and country specific requirements. Implementation of a data quality improvement strategy and achieving enhanced data quality would greatly help organizations in promoting data use for informed decision making.

  17. Process-based quality for thermal spray via feedback control

    NASA Astrophysics Data System (ADS)

    Dykhuizen, R. C.; Neiser, R. A.

    2006-09-01

    Quality control of a thermal spray system manufacturing process is difficult due to the many input variables that need to be controlled. Great care must be taken to ensure that the process remains constant to obtain a consistent quality of the parts. Control is greatly complicated by the fact that measurement of particle velocities and temperatures is a noisy stochastic process. This article illustrates the application of quality control concepts to a wire flame spray process. A central feature of the real-time control system is an automatic feedback control scheme that provides fine adjustments to ensure that uncontrolled variations are accommodated. It is shown how the control vectors can be constructed from simple process maps to independently control particle velocity and temperature. This control scheme is shown to perform well in a real production environment. We also demonstrate that slight variations in the feed wire curvature can greatly influence the process. Finally, the geometry of the spray system and sensor must remain constant for the best reproducibility.

  18. A system framework of inter-enterprise machining quality control based on fractal theory

    NASA Astrophysics Data System (ADS)

    Zhao, Liping; Qin, Yongtao; Yao, Yiyong; Yan, Peng

    2014-03-01

    In order to meet the quality control requirement of dynamic and complicated product machining processes among enterprises, a system framework of inter-enterprise machining quality control based on fractal was proposed. In this system framework, the fractal-specific characteristic of inter-enterprise machining quality control function was analysed, and the model of inter-enterprise machining quality control was constructed by the nature of fractal structures. Furthermore, the goal-driven strategy of inter-enterprise quality control and the dynamic organisation strategy of inter-enterprise quality improvement were constructed by the characteristic analysis on this model. In addition, the architecture of inter-enterprise machining quality control based on fractal was established by means of Web service. Finally, a case study for application was presented. The result showed that the proposed method was available, and could provide guidance for quality control and support for product reliability in inter-enterprise machining processes.

  19. Preparation and Quality Control of 68Ga-Citrate for PET Applications

    PubMed Central

    Aghanejad, Ayuob; Jalilian, Amir Reza; Ardaneh, Khosro; Bolourinovin, Fatemeh; Yousefnia, Hassan; Samani, Ali Bahrami

    2015-01-01

    Objective(s): In nuclear medicine studies, gallium-68 (8Ga) citrate has been recently known as a suitable infection agent in positron emission tomography (PET). In this study, by applying an in-house produced 68Ge/68Ga generator, a simple technique for the synthesis and quality control of 68Ga-citrate was introduced; followed by preliminary animal studies. Methods: 68GaCl3 eluted from the generator was studied in terms of quality control factors including radiochemical purity (assessed by HPLC and RTLC), chemical purity (assessed by ICP-EOS), radionuclide purity (evaluated by HPGe), and breakthrough. 68Ga-citrate was prepared from eluted 68GaCl3 and sodium citrate under various reaction conditions. Stability of the complex was evaluated in human serum for 2 h at 370C, followed by biodistribution studies in rats for 120 min. Results: 68Ga-citrate was prepared with acceptable radiochemical purity (>97 ITLC and >98% HPLC), specific activity (4-6 GBq/mM), chemical purity (Sn, Fe<0.3 ppm and Zn<0.2 ppm) within 15 min at 500C. The biodistribution of 68Ga-citrate was consistent with former reports up to 120 minutes. Conclusion: This study demonstrated the possible in-house preparation and quality control of 68Ga-citrate, using a commercially available 68Ge/68Ga generator for PET imaging throughout the country. PMID:27408889

  20. Application of reiteration of Hankel singular value decomposition in quality control

    NASA Astrophysics Data System (ADS)

    Staniszewski, Michał; Skorupa, Agnieszka; Boguszewicz, Łukasz; Michalczuk, Agnieszka; Wereszczyński, Kamil; Wicher, Magdalena; Konopka, Marek; Sokół, Maria; Polański, Andrzej

    2017-07-01

    Medical centres are obliged to store past medical records, including the results of quality assurance (QA) tests of the medical equipment, which is especially useful in checking reproducibility of medical devices and procedures. Analysis of multivariate time series is an important part of quality control of NMR data. In this work we proposean anomaly detection tool based on Reiteration of Hankel Singular Value Decomposition method. The presented method was compared with external software and authors obtained comparable results.

  1. Quality By Design: Concept To Applications.

    PubMed

    Swain, Suryakanta; Padhy, Rabinarayan; Jena, Bikash Ranjan; Babu, Sitty Manohar

    2018-03-08

    Quality by Design is associated to the modern, systematic, scientific and novel approach which is concerned with pre-distinct objectives that not only focus on product, process understanding but also leads to process control. It predominantly signifies the design and product improvement and the manufacturing process in order to fulfill the predefined manufactured goods or final products quality characteristics. It is quite essential to identify desire and required product performance report such as Target Product Profile, typical Quality Target Product Profile (QTPP) and Critical Quality attributes (CQA). This review highlighted about the concepts of QbD design space, for critical material attributes (CMAs) as well as the critical process parameters that can totally affect the CQAs within which the process shall be unaffected and consistently manufacture the required product. Risk assessment tools and design of experiments are its prime components. This paper outlines the basic knowledge of QbD, the key elements; steps as well as various tools for QbD implementation in pharmaceutics field are presented briefly. In addition to this, quite a lot of applications of QbD in numerous pharmaceutical related unit operations are discussed and summarized. This article provides a complete data as well as the road map for universal implementation and application of QbD for pharmaceutical products. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  2. Application submission date reflects applicant quality.

    PubMed

    Fuhrman, George M; Dada, Stephen; Ehleben, Carole

    2008-01-01

    Applications for general surgery residency are submitted through the Electronic Residency Application Service (ERAS) beginning in early September. The purpose of this study was to determine whether the date of application submission could be used in the screening of an applicant for general surgery residency. The 2007 ERAS data for an independent program that accepts 2 categorical residents per year was evaluated. International medical graduates were excluded because no international applicants were considered for interviews. Applicants for preliminary positions were also excluded. The remaining graduates from medical schools accredited by the Liaison Committee on Medical Education (LCME) who applied for categorical positions were evaluated based on United States Medical Licensing Examination (USMLE) scores and on medical school performance, as well as on the quality of their personal statements and letters of recommendation. Medical school performance was determined from dean's letters and transcript information, and each applicant was classified as outstanding, average, or poor. The date of application submission was compared with USMLE scores and medical school performance. The lag time to submit an application was also evaluated and compared with whether a student was offered an interview and the assessment of the quality of that interview. Results were evaluated using analysis of variance and the Pearson correlation test to evaluate for significance. A total of 155 applications from LCME-accredited schools for categorical positions were received. The mean lag time to application for students with an outstanding medical school performance was 15.2 +/- 15.5 days compared with 37.4 +/- 26.2 days for poorly performing students (p < 0.01). A negative correlation between USMLE score and the lag time to application was noted (p < 0.01 USMLE I and USMLE II). Applicants offered an interview demonstrated a lag time to submit their application of 19.2 days +/- 21

  3. QUALITY CONTROLS FOR PCR

    EPA Science Inventory

    The purpose of this presentation is to present an overview of the quality control (QC) sections of a draft EPA document entitled, "Quality Assurance/Quality Control Guidance for Laboratories Performing PCR Analyses on Environmental Samples." This document has been prepared by th...

  4. Controlled dehydration improves the diffraction quality of two RNA crystals.

    PubMed

    Park, HaJeung; Tran, Tuan; Lee, Jun Hyuck; Park, Hyun; Disney, Matthew D

    2016-11-03

    Post-crystallization dehydration methods, applying either vapor diffusion or humidity control devices, have been widely used to improve the diffraction quality of protein crystals. Despite the fact that RNA crystals tend to diffract poorly, there is a dearth of reports on the application of dehydration methods to improve the diffraction quality of RNA crystals. We use dehydration techniques with a Free Mounting System (FMS, a humidity control device) to recover the poor diffraction quality of RNA crystals. These approaches were applied to RNA constructs that model various RNA-mediated repeat expansion disorders. The method we describe herein could serve as a general tool to improve diffraction quality of RNA crystals to facilitate structure determinations.

  5. Hyperspectral imaging of water quality - past applications and future directions.

    NASA Astrophysics Data System (ADS)

    Ross, M. R. V.; Pavelsky, T.

    2017-12-01

    Inland waters control the delivery of sediment, carbon, and nutrients from land to ocean by transforming, depositing, and transporting constituents downstream. However, the dominant in situ conditions that control these processes are poorly constrained, especially at larger spatial scales. Hyperspectral imaging, a remote sensing technique that uses reflectance in hundreds of narrow spectral bands, can be used to estimate water quality parameters like sediment and carbon concentration over larger water bodies. Here, we review methods and applications for using hyperspectral imagery to generate near-surface two-dimensional models of water quality in lakes and rivers. Further, we show applications using newly available data from the National Ecological Observation Network aerial observation platform in the Black Warrior and Tombigbee Rivers, Alabama. We demonstrate large spatial variation in chlorophyll, colored dissolved organic matter, and turbidity in each river and uneven mixing of water quality constituents for several kilometers. Finally, we demonstrate some novel techniques using hyperspectral imagery to deconvolve dissolved organic matter spectral signatures to specific organic matter components.

  6. Application of Statistical Quality Control Techniques to Detonator Fabrication: Feasibility Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, J. Frank

    1971-05-20

    A feasibility study was performed on the use of process control techniques which might reduce the need for a duplicate inspection by production inspection and quality control inspection. Two active detonator fabrication programs were selected for the study. Inspection areas accounting for the greatest percentage of total inspection costs were selected by applying "Pareto's Principle of Maldistribution." Data from these areas were then gathered and analyzed by a process capabiltiy study.

  7. A case study: application of statistical process control tool for determining process capability and sigma level.

    PubMed

    Chopra, Vikram; Bairagi, Mukesh; Trivedi, P; Nagar, Mona

    2012-01-01

    Statistical process control is the application of statistical methods to the measurement and analysis of variation process. Various regulatory authorities such as Validation Guidance for Industry (2011), International Conference on Harmonisation ICH Q10 (2009), the Health Canada guidelines (2009), Health Science Authority, Singapore: Guidance for Product Quality Review (2008), and International Organization for Standardization ISO-9000:2005 provide regulatory support for the application of statistical process control for better process control and understanding. In this study risk assessments, normal probability distributions, control charts, and capability charts are employed for selection of critical quality attributes, determination of normal probability distribution, statistical stability, and capability of production processes, respectively. The objective of this study is to determine tablet production process quality in the form of sigma process capability. By interpreting data and graph trends, forecasting of critical quality attributes, sigma process capability, and stability of process were studied. The overall study contributes to an assessment of process at the sigma level with respect to out-of-specification attributes produced. Finally, the study will point to an area where the application of quality improvement and quality risk assessment principles for achievement of six sigma-capable processes is possible. Statistical process control is the most advantageous tool for determination of the quality of any production process. This tool is new for the pharmaceutical tablet production process. In the case of pharmaceutical tablet production processes, the quality control parameters act as quality assessment parameters. Application of risk assessment provides selection of critical quality attributes among quality control parameters. Sequential application of normality distributions, control charts, and capability analyses provides a valid statistical

  8. Rotorcraft flying qualities improvement using advanced control

    NASA Technical Reports Server (NTRS)

    Walker, D.; Postlethwaite, I.; Howitt, J.; Foster, N.

    1993-01-01

    We report on recent experience gained when a multivariable helicopter flight control law was tested on the Large Motion Simulator (LMS) at DRA Bedford. This was part of a study into the application of multivariable control theory to the design of full-authority flight control systems for high-performance helicopters. In this paper, we present some of the results that were obtained during the piloted simulation trial and from subsequent off-line simulation and analysis. The performance provided by the control law led to level 1 handling quality ratings for almost all of the mission task elements assessed, both during the real-time and off-line analysis.

  9. Pharmaceutical quality by design: product and process development, understanding, and control.

    PubMed

    Yu, Lawrence X

    2008-04-01

    The purpose of this paper is to discuss the pharmaceutical Quality by Design (QbD) and describe how it can be used to ensure pharmaceutical quality. The QbD was described and some of its elements identified. Process parameters and quality attributes were identified for each unit operation during manufacture of solid oral dosage forms. The use of QbD was contrasted with the evaluation of product quality by testing alone. The QbD is a systemic approach to pharmaceutical development. It means designing and developing formulations and manufacturing processes to ensure predefined product quality. Some of the QbD elements include: Defining target product quality profile; Designing product and manufacturing processes; Identifying critical quality attributes, process parameters, and sources of variability; Controlling manufacturing processes to produce consistent quality over time. Using QbD, pharmaceutical quality is assured by understanding and controlling formulation and manufacturing variables. Product testing confirms the product quality. Implementation of QbD will enable transformation of the chemistry, manufacturing, and controls (CMC) review of abbreviated new drug applications (ANDAs) into a science-based pharmaceutical quality assessment.

  10. Computer applications in scientific balloon quality control

    NASA Astrophysics Data System (ADS)

    Seely, Loren G.; Smith, Michael S.

    Seal defects and seal tensile strength are primary determinants of product quality in scientific balloon manufacturing; they therefore require a unit of quality measure. The availability of inexpensive and powerful data-processing tools can serve as the basis of a quality-trends-discerning analysis of products. The results of one such analysis are presently given in graphic form for use on the production floor. Software descriptions and their sample outputs are presented, together with a summary of overall and long-term effects of these methods on product quality.

  11. [On-site quality control of acupuncture randomized controlled trial: design of content and checklist of quality control based on PICOST].

    PubMed

    Li, Hong-Jiao; He, Li-Yun; Liu, Zhi-Shun; Sun, Ya-Nan; Yan, Shi-Yan; Liu, Jia; Zhao, Ye; Liu, Bao-Yan

    2014-02-01

    To effectively guarantee quality of randomized controlld trial (RCT) of acupuncture and develop reasonable content and checklist of on-site quality control, influencing factors on quality of acupuncture RCT are analyzed and scientificity of quality control content and feasibility of on-site manipulation are put into overall consideration. Based on content and checklist of on-site quality control in National 11th Five-Year Plan Project Optimization of Comprehensive Treatment Plan for TCM in Prevention and Treatment of Serious Disease and Clinical Assessment on Generic Technology and Quality Control Research, it is proposed that on-site quality control of acupuncture RCT should be conducted with PICOST (patient, intervention, comparison, out come, site and time) as core, especially on quality control of interveners' skills and outcome assessment of blinding, and checklist of on-site quality control is developed to provide references for undertaking groups of the project.

  12. Epidemiology and quality assurance: applications at farm level.

    PubMed

    Noordhuizen, J P; Frankena, K

    1999-03-29

    Animal production is relevant with respect to farm income and the position of the sector in the market, but also with respect to the quality and safety of products of animal origin, related to public health. Animal production is part of a chain of food production. Therefore, producers have to take consumer expectations and demands in the domains of animal health, welfare and environment into account. A different attitude for production has to be adopted; this attitude can be visualized in good farming practice, GFP, codes. Farmers who focused on quality in its broadest sense need a system supporting them in their management and control of quality risks. Generally speaking, there are three systems for that purpose: GFP, ISO and HACCP. When the hypothesis followed relates to animal health being a feature of quality, or else welfare and environmental issues, then animal health care can be executed following quality control principles. The HACCP concept is well suited for quality control at farm level, involving risk identification and risk management. The on-farm monitoring and surveillance system of critical control points in the animal production process is the most important tool in this procedure. Principles for HACCP application as well as certification fitness of HACCP are elaborated upon. They are illustrated by using salmonellosis in meat-pig farms as objective for an HACCP approach. It is further discussed that, in addition to animal health and quality, animal welfare and environmental issues could also be covered by an HACCP-like system in an integrated manner. Ultimately, the HACCP modules could end up in an overall ISO certification.

  13. 21 CFR 106.1 - Status and applicability of the quality control procedures regulation.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION INFANT FORMULA QUALITY CONTROL PROCEDURES... infant formula meets the safety, quality, and nutrient requirements of section 412 of the act and the..., processing, and packaging of an infant formula shall render such formula adulterated under section 412(a)(1...

  14. 21 CFR 106.1 - Status and applicability of the quality control procedures regulation.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION INFANT FORMULA QUALITY CONTROL PROCEDURES... infant formula meets the safety, quality, and nutrient requirements of section 412 of the act and the..., processing, and packaging of an infant formula shall render such formula adulterated under section 412(a)(1...

  15. An Application of Six Sigma to Reduce Supplier Quality Cost

    NASA Astrophysics Data System (ADS)

    Gaikwad, Lokpriya Mohanrao; Teli, Shivagond Nagappa; Majali, Vijay Shashikant; Bhushi, Umesh Mahadevappa

    2016-01-01

    This article presents an application of Six Sigma to reduce supplier quality cost in manufacturing industry. Although there is a wider acceptance of Six Sigma in many organizations today, there is still a lack of in-depth case study of Six Sigma. For the present research the case study methodology was used. The company decided to reduce quality cost and improve selected processes using Six Sigma methodologies. Regarding the fact that there is a lack of case studies dealing with Six Sigma especially in individual manufacturing organization this article could be of great importance also for the practitioners. This paper discusses the quality and productivity improvement in a supplier enterprise through a case study. The paper deals with an application of Six Sigma define-measure-analyze-improve-control methodology in an industry which provides a framework to identify, quantify and eliminate sources of variation in an operational process in question, to optimize the operation variables, improve and sustain performance viz. process yield with well-executed control plans. Six Sigma improves the process performance (process yield) of the critical operational process, leading to better utilization of resources, decreases variations and maintains consistent quality of the process output.

  16. Application of Sigma Metrics Analysis for the Assessment and Modification of Quality Control Program in the Clinical Chemistry Laboratory of a Tertiary Care Hospital.

    PubMed

    Iqbal, Sahar; Mustansar, Tazeen

    2017-03-01

    Sigma is a metric that quantifies the performance of a process as a rate of Defects-Per-Million opportunities. In clinical laboratories, sigma metric analysis is used to assess the performance of laboratory process system. Sigma metric is also used as a quality management strategy for a laboratory process to improve the quality by addressing the errors after identification. The aim of this study is to evaluate the errors in quality control of analytical phase of laboratory system by sigma metric. For this purpose sigma metric analysis was done for analytes using the internal and external quality control as quality indicators. Results of sigma metric analysis were used to identify the gaps and need for modification in the strategy of laboratory quality control procedure. Sigma metric was calculated for quality control program of ten clinical chemistry analytes including glucose, chloride, cholesterol, triglyceride, HDL, albumin, direct bilirubin, total bilirubin, protein and creatinine, at two control levels. To calculate the sigma metric imprecision and bias was calculated with internal and external quality control data, respectively. The minimum acceptable performance was considered as 3 sigma. Westgard sigma rules were applied to customize the quality control procedure. Sigma level was found acceptable (≥3) for glucose (L2), cholesterol, triglyceride, HDL, direct bilirubin and creatinine at both levels of control. For rest of the analytes sigma metric was found <3. The lowest value for sigma was found for chloride (1.1) at L2. The highest value of sigma was found for creatinine (10.1) at L3. HDL was found with the highest sigma values at both control levels (8.8 and 8.0 at L2 and L3, respectively). We conclude that analytes with the sigma value <3 are required strict monitoring and modification in quality control procedure. In this study application of sigma rules provided us the practical solution for improved and focused design of QC procedure.

  17. Quality Control Charts in Large-Scale Assessment Programs

    ERIC Educational Resources Information Center

    Schafer, William D.; Coverdale, Bradley J.; Luxenberg, Harlan; Jin, Ying

    2011-01-01

    There are relatively few examples of quantitative approaches to quality control in educational assessment and accountability contexts. Among the several techniques that are used in other fields, Shewart charts have been found in a few instances to be applicable in educational settings. This paper describes Shewart charts and gives examples of how…

  18. Enhanced Quality Control in Pharmaceutical Applications by Combining Raman Spectroscopy and Machine Learning Techniques

    NASA Astrophysics Data System (ADS)

    Martinez, J. C.; Guzmán-Sepúlveda, J. R.; Bolañoz Evia, G. R.; Córdova, T.; Guzmán-Cabrera, R.

    2018-06-01

    In this work, we applied machine learning techniques to Raman spectra for the characterization and classification of manufactured pharmaceutical products. Our measurements were taken with commercial equipment, for accurate assessment of variations with respect to one calibrated control sample. Unlike the typical use of Raman spectroscopy in pharmaceutical applications, in our approach the principal components of the Raman spectrum are used concurrently as attributes in machine learning algorithms. This permits an efficient comparison and classification of the spectra measured from the samples under study. This also allows for accurate quality control as all relevant spectral components are considered simultaneously. We demonstrate our approach with respect to the specific case of acetaminophen, which is one of the most widely used analgesics in the market. In the experiments, commercial samples from thirteen different laboratories were analyzed and compared against a control sample. The raw data were analyzed based on an arithmetic difference between the nominal active substance and the measured values in each commercial sample. The principal component analysis was applied to the data for quantitative verification (i.e., without considering the actual concentration of the active substance) of the difference in the calibrated sample. Our results show that by following this approach adulterations in pharmaceutical compositions can be clearly identified and accurately quantified.

  19. [Quality control in anesthesiology].

    PubMed

    Muñoz-Ramón, J M

    1995-03-01

    The process of quality control and auditing of anesthesiology allows us to evaluate care given by a service and solve problems that are detected. Quality control is a basic element of care giving and is only secondarily an area of academic research; it is therefore a meaningless effort if the information does not serve to improve departmental procedures. Quality assurance procedures assume certain infrastructural requirements and an initial period of implementation and adjustment. The main objectives of quality control are the reduction of morbidity and mortality due to anesthesia, assurance of the availability and proper management of resources and, finally, the well-being and safety of the patient.

  20. Cryopreservation in fish: current status and pathways to quality assurance and quality control in repository development

    PubMed Central

    Torres, Leticia; Hu, E.; Tiersch, Terrence R.

    2017-01-01

    Cryopreservation in aquatic species in general has been constrained to research activities for more than 60 years. Although the need for application and commercialisation pathways has become clear, the lack of comprehensive quality assurance and quality control programs has impeded the progress of the field, delaying the establishment of germplasm repositories and commercial-scale applications. In this review we focus on the opportunities for standardisation in the practices involved in the four main stages of the cryopreservation process: (1) source, housing and conditioning of fish; (2) sample collection and preparation; (3) freezing and cryogenic storage of samples; and (4) egg collection and use of thawed sperm samples. In addition, we introduce some key factors that would assist the transition to commercial-scale, high-throughput application. PMID:26739583

  1. Commercial jet fuel quality control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strauss, K.H.

    1995-05-01

    The paper discusses the purpose of jet fuel quality control between the refinery and the aircraft. It describes fixed equipment, including various types of filters, and the usefulness and limitations of this equipment. Test equipment is reviewed as are various surveillance procedures. These include the Air Transport Association specification ATA 103, the FAA Advisory Circular 150/5230-4, the International Air Transport Association Guidance Material for Fuel Quality Control and Fuelling Service and the Guidelines for Quality Control at Jointly Operated Fuel Systems. Some past and current quality control problems are briefly mentioned.

  2. Application of indices Cp and Cpk to improve quality control capability in clinical biochemistry laboratories.

    PubMed

    Chen, Ming-Shu; Wu, Ming-Hsun; Lin, Chih-Ming

    2014-04-30

    The traditional criteria for acceptability of analytic quality may not be objective in clinical laboratories. To establish quality control procedures intended to enhance Westgard multi-rules for improving the quality of clinical biochemistry tests, we applied the Cp and Cpk quality-control indices to monitor tolerance fitting and systematic variation of clinical biochemistry test results. Daily quality-control data of a large Taiwanese hospital in 2009 were analyzed. The test items were selected based on an Olympus biochemistry machine and included serum albumin, aspartate aminotransferase, cholesterol, glucose and potassium levels. Cp and Cpk values were calculated for normal and abnormal levels, respectively. The tolerance range was estimated with data from 50 laboratories using the same instruments and reagents. The results showed a monthly trend of variation for the five items under investigation. The index values of glucose were lower than those of the other items, and their values were usually <2. In contrast to the Cp value for cholesterol, Cpk of cholesterol was lower than 2, indicating a systematic error that should be further investigated. This finding suggests a degree of variation or failure to meet specifications that should be corrected. The study indicated that Cp and Cpk could be applied not only for monitoring variations in quality control, but also for revealing inter-laboratory qualitycontrol capability differences.

  3. Implementation of Quality Assurance and Quality Control Measures in the National Phenology Database

    NASA Astrophysics Data System (ADS)

    Gerst, K.; Rosemartin, A.; Denny, E. G.; Marsh, L.; Barnett, L.

    2015-12-01

    The USA National Phenology Network (USA-NPN; www.usanpn.org) serves science and society by promoting a broad understanding of plant and animal phenology and the relationships among phenological patterns and environmental change. The National Phenology Database has over 5.5 million observation records for plants and animals for the period 1954-2015. These data have been used in a number of science, conservation and resource management applications, including national assessments of historical and potential future trends in phenology, regional assessments of spatio-temporal variation in organismal activity, and local monitoring for invasive species detection. Customizable data downloads are freely available, and data are accompanied by FGDC-compliant metadata, data-use and data-attribution policies, and vetted documented methodologies and protocols. The USA-NPN has implemented a number of measures to ensure both quality assurance and quality control. Here we describe the resources that have been developed so that incoming data submitted by both citizen and professional scientists are reliable; these include training materials, such as a botanical primer and species profiles. We also describe a number of automated quality control processes applied to incoming data streams to optimize data output quality. Existing and planned quality control measures for output of raw and derived data include: (1) Validation of site locations, including latitude, longitude, and elevation; (2) Flagging of records that conflict for a given date for an individual plant; (3) Flagging where species occur outside known ranges; (4) Flagging of records when phenophases occur outside of the plausible order for a species; (5) Flagging of records when intensity measures do not follow a plausible progression for a phenophase; (6) Flagging of records when a phenophase occurs outside of the plausible season, and (7) Quantification of precision and uncertainty for estimation of phenological metrics

  4. A Quantitative Quality Control Model for Parallel and Distributed Crowdsourcing Tasks

    ERIC Educational Resources Information Center

    Zhu, Shaojian

    2014-01-01

    Crowdsourcing is an emerging research area that has experienced rapid growth in the past few years. Although crowdsourcing has demonstrated its potential in numerous domains, several key challenges continue to hinder its application. One of the major challenges is quality control. How can crowdsourcing requesters effectively control the quality…

  5. Quality measures in applications of image restoration.

    PubMed

    Kriete, A; Naim, M; Schafer, L

    2001-01-01

    We describe a new method for the estimation of image quality in image restoration applications. We demonstrate this technique on a simulated data set of fluorescent beads, in comparison with restoration by three different deconvolution methods. Both the number of iterations and a regularisation factor are varied to enforce changes in the resulting image quality. First, the data sets are directly compared by an accuracy measure. These values serve to validate the image quality descriptor, which is developed on the basis of optical information theory. This most general measure takes into account the spectral energies and the noise, weighted in a logarithmic fashion. It is demonstrated that this method is particularly helpful as a user-oriented method to control the output of iterative image restorations and to eliminate the guesswork in choosing a suitable number of iterations.

  6. [Application study of human sperm motility bioassay in IVF laboratory quality control].

    PubMed

    Cai, Xia; Pomeroy, Kimball O; Mattox, John H

    2006-07-01

    To investigate the sensitivity of human sperm survival bioassay to using known concentrations of potential toxin of formalin and to elevate the application value of human sperm motility assay as a quality control method in detecting the components used in IVF program. Fresh semen was obtained from healthy males at andrology laboratory by masturbation. Sperm was processed on a gradient column of isolate medium and PBS medium. In experiment 1, the medium with 0.25%, 0.75% concentration of formalin and control medium were added to the Falcon culture tubes containing HTF medium with or without 0.3% bovine albumin serum and with or without light mineral oil. In experiment 2, in 3 types of culture tubes containing HTF medium with or without 0.3% bovine albumin serum and with or without light mineral oil, the sperm was exposed to each culture tube and cultured for 24 and 48 hrs at room temperature, and the motile sperms were counted under the microscope. The average sperm motility index in the HTF medium with 0.25% formalin at 24 hrs was 0.594 +/- 0.331, significantly higher than in the HTF medium with 0.75% formalin (0.450 +/- 0.284) (P < 0.01). In the medium containing 0.25% and 0.75% formalin with 0.3% bovine albumin serum and light mineral oil, the average sperm survival indexes were 0.683 +/- 0.334 and 0.527 +/- 0.345, respectively, higher than without bovine albumin serum and light mineral oil (0.394 +/- 0.311 and 0.424 +/- 0.311). The average sperm index of 7 ml tissue culture tube made in Denmark was 0.677 +/- 0.335, higher than the other two types of culture tubes made in the USA (0.551 +/- 0.317 and 0.596 +/- 0.327) (P < 0.001). When the sperm cultured in the medium with 0.3% bovine albumin serum and light mineral oil, the average sperm survival indexes were 0.821 +/- 0.259 and 0.645 +/- 0.335, respectively, higher than without bovine albumin serum or light mineral oil (0.571 +/- 0.321 and 0.395 +/- 0.245) (P < 0.01). The sperm survival bioassay is a sensitivity

  7. Basal Area Growth Estimators for Survivor Component: A Quality Control Application

    Treesearch

    Charles E. Thomas; Francis A. Roesch

    1990-01-01

    Several possible estimators are available for basal area growth of survivor trees, when horizontal prism (or point) plots (HPP) are remeasured. This study's comparison of three estimators not only provides a check for the estimate of basal area growth but suggests that they can provide a quality control indicator for yield procedures. An example is derived from...

  8. 40 CFR 75.21 - Quality assurance and quality control requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Quality assurance and quality control... PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Operation and Maintenance Requirements § 75.21 Quality assurance and quality control requirements. (a) Continuous emission monitoring systems. The owner or...

  9. 40 CFR 51.359 - Quality control.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 2 2013-07-01 2013-07-01 false Quality control. 51.359 Section 51.359....359 Quality control. Quality control measures shall insure that emission testing equipment is calibrated and maintained properly, and that inspection, calibration records, and control charts are...

  10. 40 CFR 51.359 - Quality control.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Quality control. 51.359 Section 51.359....359 Quality control. Quality control measures shall insure that emission testing equipment is calibrated and maintained properly, and that inspection, calibration records, and control charts are...

  11. 40 CFR 51.359 - Quality control.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 2 2011-07-01 2011-07-01 false Quality control. 51.359 Section 51.359....359 Quality control. Quality control measures shall insure that emission testing equipment is calibrated and maintained properly, and that inspection, calibration records, and control charts are...

  12. 40 CFR 51.359 - Quality control.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 2 2012-07-01 2012-07-01 false Quality control. 51.359 Section 51.359....359 Quality control. Quality control measures shall insure that emission testing equipment is calibrated and maintained properly, and that inspection, calibration records, and control charts are...

  13. Quality Assurance and Control Considerations in Environmental Measurements and Monitoring

    NASA Astrophysics Data System (ADS)

    Sedlet, Jacob

    1982-06-01

    Quality assurance and quality control have become accepted as essential parts of all environmental surveillance, measurements, and monitoring programs, both nuclear and non-nuclear. The same principles and details apply to each. It is primarily the final measurement technique that differs. As the desire and need to measure smaller amounts of pollutants with greater accuracy has increased, it has been recognized that quality assurance and control programs are cost-effective in achieving the expected results. Quality assurance (QA) consists of all the actions necessary to provide confidence in the results. Quality control (QC) is a part of QA, and consists of those actions and activities that permit the control of the individual steps in the environmental program. The distinction between the two terms is not always clearly defined, but a sharp division is not necessary. The essential principle of QA and QC is a commitment to high quality results. The essential components of a QA and QC program are a complete, written procedures manual for all parts of the environmental program, the use of standard or validated procedures, participation in applicable interlaboratory comparison or QA programs, replicate analysis and measurement, training of personnel, and a means of auditing or checking that the QA and QC programs are properly conducted. These components are discussed below in some detail.

  14. Quality Control by Artificial Vision

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lam, Edmond Y.; Gleason, Shaun Scott; Niel, Kurt S.

    2010-01-01

    Computational technology has fundamentally changed many aspects of our lives. One clear evidence is the development of artificial-vision systems, which have effectively automated many manual tasks ranging from quality inspection to quantitative assessment. In many cases, these machine-vision systems are even preferred over manual ones due to their repeatability and high precision. Such advantages come from significant research efforts in advancing sensor technology, illumination, computational hardware, and image-processing algorithms. Similar to the Special Section on Quality Control by Artificial Vision published two years ago in Volume 17, Issue 3 of the Journal of Electronic Imaging, the present one invited papersmore » relevant to fundamental technology improvements to foster quality control by artificial vision, and fine-tuned the technology for specific applications. We aim to balance both theoretical and applied work pertinent to this special section theme. Consequently, we have seven high-quality papers resulting from the stringent peer-reviewing process in place at the Journal of Electronic Imaging. Some of the papers contain extended treatment of the authors work presented at the SPIE Image Processing: Machine Vision Applications conference and the International Conference on Quality Control by Artificial Vision. On the broad application side, Liu et al. propose an unsupervised texture image segmentation scheme. Using a multilayer data condensation spectral clustering algorithm together with wavelet transform, they demonstrate the effectiveness of their approach on both texture and synthetic aperture radar images. A problem related to image segmentation is image extraction. For this, O'Leary et al. investigate the theory of polynomial moments and show how these moments can be compared to classical filters. They also show how to use the discrete polynomial-basis functions for the extraction of 3-D embossed digits, demonstrating superiority over Fourier

  15. V/STOL Dynamics, Control, and Flying Qualities

    NASA Technical Reports Server (NTRS)

    Franklin, James A.

    2000-01-01

    This publication presents material that constituted the lectures presented by the author as part of Course AA 234, Dynamics, Control, and Flying Qualities of Vertical/Short Takeoff and Landing (V/STOL) Aircraft that was taught in the Department of Aeronautics and Astronautics at Stanford University. It covers representative operations of vertical and short takeoff and landing (V/STOL) aircraft, a discussion of the pilot's strategy in controlling these aircraft, the equations of motion pertinent to V/STOL tasks, and their application in the analysis of longitudinal and lateral-directional control in hover and forward flight. Following that development, which applies to the characteristics of the basic airframe and propulsion system, the text concludes with a discussion of the contributions of control augmentation in specific flight tasks and of the integration of modern electronic displays with these controls.

  16. General aviation fuel quality control

    NASA Technical Reports Server (NTRS)

    Poitz, H.

    1983-01-01

    Quality control measures for aviation gasoline, and some of the differences between quality control on avgas and mogas are discussed. One thing to keep in mind is that with motor gasoline you can always pull off to the side of the road. It's not so easy to do in an airplane. Consequently, there are reasons for having the tight specifications and the tight quality control measures on avgas as compared to motor gasoline.

  17. Network-based production quality control

    NASA Astrophysics Data System (ADS)

    Kwon, Yongjin; Tseng, Bill; Chiou, Richard

    2007-09-01

    This study investigates the feasibility of remote quality control using a host of advanced automation equipment with Internet accessibility. Recent emphasis on product quality and reduction of waste stems from the dynamic, globalized and customer-driven market, which brings opportunities and threats to companies, depending on the response speed and production strategies. The current trends in industry also include a wide spread of distributed manufacturing systems, where design, production, and management facilities are geographically dispersed. This situation mandates not only the accessibility to remotely located production equipment for monitoring and control, but efficient means of responding to changing environment to counter process variations and diverse customer demands. To compete under such an environment, companies are striving to achieve 100%, sensor-based, automated inspection for zero-defect manufacturing. In this study, the Internet-based quality control scheme is referred to as "E-Quality for Manufacturing" or "EQM" for short. By its definition, EQM refers to a holistic approach to design and to embed efficient quality control functions in the context of network integrated manufacturing systems. Such system let designers located far away from the production facility to monitor, control and adjust the quality inspection processes as production design evolves.

  18. PQLX: A seismic data quality control system description, applications, and users manual

    USGS Publications Warehouse

    McNamara, Daniel E.; Boaz, Richard I.

    2011-01-01

    We present a detailed description and users manual for a new tool to evaluate seismic station performance and characteristics by providing quick and easy transitions between visualizations of the frequency and time domains. The software is based on the probability density functions (PDF) of power spectral densities (PSD) (McNamara and Buland, 2004) and builds on the original development of the PDF stand-alone software system (McNamara and Boaz, 2005) and the seismological data viewer application PQL (IRIS-PASSCAL Quick Look) and PQLII (available through the IRIS PASSCAL program: http://www.passcal.nmt.edu/content/pql-ii-program-viewing-data). With PQLX (PQL eXtended), computed PSDs are stored in a MySQL database, allowing a user to access specific time periods of PSDs (PDF subsets) and time series segments through a GUI-driven interface. The power of the method and software lies in the fact that there is no need to screen the data for system transients, earthquakes, or general data artifacts, because they map into a background probability level. In fact, examination of artifacts related to station operation and episodic cultural noise allow us to estimate both the overall station quality and a baseline level of Earth noise at each site. The output of this analysis tool is useful for both operational and scientific applications. Operationally, it is useful for characterizing the current and past performance of existing broadband stations, for conducting tests on potential new seismic station locations, for evaluating station baseline noise levels (McNamara and others, 2009), for detecting problems with the recording system or sensors, and for evaluating the overall quality of data and metadata. Scientifically, the tool allows for mining of PSDs for investigations on the evolution of seismic noise (for example, Aster and others, 2008; and Aster and others, 2010) and other phenomena. Currently, PQLX is operational at several organizations including the USGS National

  19. A Strategy to Establish a Quality Assurance/Quality Control Plan for the Application of Biosensors for the Detection of E. coli in Water.

    PubMed

    Hesari, Nikou; Kıratlı Yılmazçoban, Nursel; Elzein, Mohamad; Alum, Absar; Abbaszadegan, Morteza

    2017-01-03

    Rapid bacterial detection using biosensors is a novel approach for microbiological testing applications. Validation of such methods is an obstacle in the adoption of new bio-sensing technologies for water testing. Therefore, establishing a quality assurance and quality control (QA/QC) plan is essential to demonstrate accuracy and reliability of the biosensor method for the detection of E. coli in drinking water samples. In this study, different reagents and assay conditions including temperatures, holding time, E. coli strains and concentrations, dissolving agents, salinity and pH effects, quality of substrates of various suppliers of 4-methylumbelliferyl glucuronide (MUG), and environmental water samples were included in the QA/QC plan and used in the assay optimization and documentation. Furthermore, the procedural QA/QC for the monitoring of drinking water samples was established to validate the performance of the biosensor platform for the detection of E. coli using a culture-based standard technique. Implementing the developed QA/QC plan, the same level of precision and accuracy was achieved using both the standard and the biosensor methods. The established procedural QA/QC for the biosensor will provide a reliable tool for a near real-time monitoring of E. coli in drinking water samples to both industry and regulatory authorities.

  20. A Strategy to Establish a Quality Assurance/Quality Control Plan for the Application of Biosensors for the Detection of E. coli in Water

    PubMed Central

    Hesari, Nikou; Kıratlı Yılmazçoban, Nursel; Elzein, Mohamad; Alum, Absar; Abbaszadegan, Morteza

    2017-01-01

    Rapid bacterial detection using biosensors is a novel approach for microbiological testing applications. Validation of such methods is an obstacle in the adoption of new bio-sensing technologies for water testing. Therefore, establishing a quality assurance and quality control (QA/QC) plan is essential to demonstrate accuracy and reliability of the biosensor method for the detection of E. coli in drinking water samples. In this study, different reagents and assay conditions including temperatures, holding time, E. coli strains and concentrations, dissolving agents, salinity and pH effects, quality of substrates of various suppliers of 4-methylumbelliferyl glucuronide (MUG), and environmental water samples were included in the QA/QC plan and used in the assay optimization and documentation. Furthermore, the procedural QA/QC for the monitoring of drinking water samples was established to validate the performance of the biosensor platform for the detection of E. coli using a culture-based standard technique. Implementing the developed QA/QC plan, the same level of precision and accuracy was achieved using both the standard and the biosensor methods. The established procedural QA/QC for the biosensor will provide a reliable tool for a near real-time monitoring of E. coli in drinking water samples to both industry and regulatory authorities. PMID:28054956

  1. 40 CFR 51.359 - Quality control.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 2 2014-07-01 2014-07-01 false Quality control. 51.359 Section 51.359 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS REQUIREMENTS FOR... to assure test accuracy. Computer control of quality assurance checks and quality control charts...

  2. Application Research of Quality Control Technology of Asphalt Pavement based on GPS Intelligent

    NASA Astrophysics Data System (ADS)

    Wang, Min; Gao, Bo; Shang, Fei; Wang, Tao

    2017-10-01

    Due to the difficulty of steel deck pavement asphalt layer compaction caused by the effect of the flexible supporting system (orthotropic steel deck plate), it is usually hard and difficult to control for the site compactness to reach the design goal. The intelligent compaction technology is based on GPS control technology and real-time acquisition of actual compaction tracks, and then forms a cloud maps of compaction times, which guide the roller operator to do the compaction in accordance with the design requirement to ensure the deck compaction technology and compaction quality. From the actual construction situation of actual bridge and checked data, the intelligent compaction technology is significant in guaranteeing the steel deck asphalt pavement compactness and quality stability.

  3. [Development of whole process quality control and management system of traditional Chinese medicine decoction pieces based on traditional Chinese medicine quality tree].

    PubMed

    Yu, Wen-Kang; Dong, Ling; Pei, Wen-Xuan; Sun, Zhi-Rong; Dai, Jun-Dong; Wang, Yun

    2017-12-01

    The whole process quality control and management of traditional Chinese medicine (TCM) decoction pieces is a system engineering, involving the base environment, seeds and seedlings, harvesting, processing and other multiple steps, so the accurate identification of factors in TCM production process that may induce the quality risk, as well as reasonable quality control measures are very important. At present, the concept of quality risk is mainly concentrated in the aspects of management and regulations, etc. There is no comprehensive analysis on possible risks in the quality control process of TCM decoction pieces, or analysis summary of effective quality control schemes. A whole process quality control and management system for TCM decoction pieces based on TCM quality tree was proposed in this study. This system effectively combined the process analysis method of TCM quality tree with the quality risk management, and can help managers to make real-time decisions while realizing the whole process quality control of TCM. By providing personalized web interface, this system can realize user-oriented information feedback, and was convenient for users to predict, evaluate and control the quality of TCM. In the application process, the whole process quality control and management system of the TCM decoction pieces can identify the related quality factors such as base environment, cultivation and pieces processing, extend and modify the existing scientific workflow according to their own production conditions, and provide different enterprises with their own quality systems, to achieve the personalized service. As a new quality management model, this paper can provide reference for improving the quality of Chinese medicine production and quality standardization. Copyright© by the Chinese Pharmaceutical Association.

  4. Adaptation of Collaborative Applications for Network Quality Variation

    DTIC Science & Technology

    2004-06-01

    collaborative application. 1.1 Quality of Service Quality of Service (QoS) is generally regarded as an end-to-end network application...using the Cloud WAN Emulator [14]. We used qtcp1 to measure end-to-end network service quality between the signal sender and the signal receiver. The...application must be aware of current resource 1 Qtcp measures end-to-end network integrity and service quality for QoS verification. Qtcp sends a

  5. The Cost of Quality--Its Application to Libraries.

    ERIC Educational Resources Information Center

    Franklin, Brinley

    1994-01-01

    Examines the conceptual basis for the cost of quality and its application to libraries. The framework for analysis of this conceptual basis includes definitions of the cost of quality; a brief historical review of the cost of quality; and the application of quality cost to libraries, including an explanation of how quality costs respond to quality…

  6. 7 CFR 981.42 - Quality control.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Quality control. 981.42 Section 981.42 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Regulating Handling Quality Control § 981.42 Quality control. (a) Incoming. Except as provided in this...

  7. 7 CFR 981.42 - Quality control.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Quality control. 981.42 Section 981.42 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING AGREEMENTS... Regulating Handling Quality Control § 981.42 Quality control. (a) Incoming. Except as provided in this...

  8. 7 CFR 981.42 - Quality control.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Quality control. 981.42 Section 981.42 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Regulating Handling Quality Control § 981.42 Quality control. (a) Incoming. Except as provided in this...

  9. 7 CFR 981.42 - Quality control.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Quality control. 981.42 Section 981.42 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Regulating Handling Quality Control § 981.42 Quality control. (a) Incoming. Except as provided in this...

  10. 7 CFR 930.44 - Quality control.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Quality control. 930.44 Section 930.44 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Control § 930.44 Quality control. (a) Quality standards. The Board may establish, with the approval of the...

  11. 7 CFR 930.44 - Quality control.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Quality control. 930.44 Section 930.44 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Control § 930.44 Quality control. (a) Quality standards. The Board may establish, with the approval of the...

  12. 7 CFR 930.44 - Quality control.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Quality control. 930.44 Section 930.44 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Control § 930.44 Quality control. (a) Quality standards. The Board may establish, with the approval of the...

  13. 7 CFR 930.44 - Quality control.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Quality control. 930.44 Section 930.44 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING AGREEMENTS... Control § 930.44 Quality control. (a) Quality standards. The Board may establish, with the approval of the...

  14. Quality and Control of Water Vapor Winds

    NASA Technical Reports Server (NTRS)

    Jedlovec, Gary J.; Atkinson, Robert J.

    1996-01-01

    Water vapor imagery from the geostationary satellites such as GOES, Meteosat, and GMS provides synoptic views of dynamical events on a continual basis. Because the imagery represents a non-linear combination of mid- and upper-tropospheric thermodynamic parameters (three-dimensional variations in temperature and humidity), video loops of these image products provide enlightening views of regional flow fields, the movement of tropical and extratropical storm systems, the transfer of moisture between hemispheres and from the tropics to the mid- latitudes, and the dominance of high pressure systems over particular regions of the Earth. Despite the obvious larger scale features, the water vapor imagery contains significant image variability down to the single 8 km GOES pixel. These features can be quantitatively identified and tracked from one time to the next using various image processing techniques. Merrill et al. (1991), Hayden and Schmidt (1992), and Laurent (1993) have documented the operational procedures and capabilities of NOAA and ESOC to produce cloud and water vapor winds. These techniques employ standard correlation and template matching approaches to wind tracking and use qualitative and quantitative procedures to eliminate bad wind vectors from the wind data set. Techniques have also been developed to improve the quality of the operational winds though robust editing procedures (Hayden and Veldon 1991). These quality and control approaches have limitations, are often subjective, and constrain wind variability to be consistent with model derived wind fields. This paper describes research focused on the refinement of objective quality and control parameters for water vapor wind vector data sets. New quality and control measures are developed and employed to provide a more robust wind data set for climate analysis, data assimilation studies, as well as operational weather forecasting. The parameters are applicable to cloud-tracked winds as well with minor

  15. 40 CFR 227.31 - Applicable marine water quality criteria.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Applicable marine water quality... § 227.31 Applicable marine water quality criteria. Applicable marine water quality criteria means the criteria given for marine waters in the EPA publication “Quality Criteria for Water” as published in 1976...

  16. 40 CFR 227.31 - Applicable marine water quality criteria.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Applicable marine water quality... § 227.31 Applicable marine water quality criteria. Applicable marine water quality criteria means the criteria given for marine waters in the EPA publication “Quality Criteria for Water” as published in 1976...

  17. 40 CFR 227.31 - Applicable marine water quality criteria.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Applicable marine water quality... § 227.31 Applicable marine water quality criteria. Applicable marine water quality criteria means the criteria given for marine waters in the EPA publication “Quality Criteria for Water” as published in 1976...

  18. Adaptive weld control for high-integrity welding applications

    NASA Technical Reports Server (NTRS)

    Powell, Bradley W.

    1993-01-01

    An advanced adaptive control weld system for high-integrity welding applications is presented. The system consists of a state-of-the-art weld control subsystem, motion control subsystem, and sensor subsystem which closes the loop on the process. The adaptive control subsystem (ACS), which is required to totally close the loop on weld process control, consists of a multiprocessor system, data acquisition hardware, and three welding sensors which provide measurements from all areas around the torch in real time. The ACS acquires all 'measurables' and feeds offset trims back into the weld control and motion control subsystems to modify the 'controllables' in order to maintain a previously defined weld quality.

  19. Human Connectome Project Informatics: quality control, database services, and data visualization

    PubMed Central

    Marcus, Daniel S.; Harms, Michael P.; Snyder, Abraham Z.; Jenkinson, Mark; Wilson, J Anthony; Glasser, Matthew F.; Barch, Deanna M.; Archie, Kevin A.; Burgess, Gregory C.; Ramaratnam, Mohana; Hodge, Michael; Horton, William; Herrick, Rick; Olsen, Timothy; McKay, Michael; House, Matthew; Hileman, Michael; Reid, Erin; Harwell, John; Coalson, Timothy; Schindler, Jon; Elam, Jennifer S.; Curtiss, Sandra W.; Van Essen, David C.

    2013-01-01

    The Human Connectome Project (HCP) has developed protocols, standard operating and quality control procedures, and a suite of informatics tools to enable high throughput data collection, data sharing, automated data processing and analysis, and data mining and visualization. Quality control procedures include methods to maintain data collection consistency over time, to measure head motion, and to establish quantitative modality-specific overall quality assessments. Database services developed as customizations of the XNAT imaging informatics platform support both internal daily operations and open access data sharing. The Connectome Workbench visualization environment enables user interaction with HCP data and is increasingly integrated with the HCP's database services. Here we describe the current state of these procedures and tools and their application in the ongoing HCP study. PMID:23707591

  20. Application of sigma metrics for the assessment of quality control in clinical chemistry laboratory in Ghana: A pilot study.

    PubMed

    Afrifa, Justice; Gyekye, Seth A; Owiredu, William K B A; Ephraim, Richard K D; Essien-Baidoo, Samuel; Amoah, Samuel; Simpong, David L; Arthur, Aaron R

    2015-01-01

    Sigma metrics provide a uniquely defined scale with which we can assess the performance of a laboratory. The objective of this study was to assess the internal quality control (QC) in the clinical chemistry laboratory of the University of Cape Cost Hospital (UCC) using the six sigma metrics application. We used commercial control serum [normal (L1) and pathological (L2)] for validation of quality control. Metabolites (glucose, urea, and creatinine), lipids [triglycerides (TG), total cholesterol, high-density lipoprotein cholesterol (HDL-C)], enzymes [alkaline phosphatase (ALP), alanine aminotransferase (AST)], electrolytes (sodium, potassium, chloride) and total protein were assessed. Between-day imprecision (CVs), inaccuracy (Bias) and sigma values were calculated for each control level. Apart from sodium (2.40%, 3.83%), chloride (2.52% and 2.51%) for both L1 and L2 respectively, and glucose (4.82%), cholesterol (4.86%) for L2, CVs for all other parameters (both L1 and L2) were >5%. Four parameters (HDL-C, urea, creatinine and potassium) achieved sigma levels >1 for both controls. Chloride and sodium achieved sigma levels >1 for L1 but <1 for L2. In contrast, cholesterol, total protein and AST achieved sigma levels <1 for L1 but >1 for L2. Glucose and ALP achieved a sigma level >1 for both control levels whereas TG achieved a sigma level >2 for both control levels. Unsatisfactory sigma levels (<3) where achieved for all parameters using both control levels, this shows instability and low consistency of results. There is the need for detailed assessment of the analytical procedures and the strengthening of the laboratory control systems in order to achieve effective six sigma levels for the laboratory.

  1. Application of sigma metrics for the assessment of quality control in clinical chemistry laboratory in Ghana: A pilot study

    PubMed Central

    Afrifa, Justice; Gyekye, Seth A.; Owiredu, William K. B. A.; Ephraim, Richard K. D.; Essien-Baidoo, Samuel; Amoah, Samuel; Simpong, David L.; Arthur, Aaron R.

    2015-01-01

    Background: Sigma metrics provide a uniquely defined scale with which we can assess the performance of a laboratory. The objective of this study was to assess the internal quality control (QC) in the clinical chemistry laboratory of the University of Cape Cost Hospital (UCC) using the six sigma metrics application. Materials and Methods: We used commercial control serum [normal (L1) and pathological (L2)] for validation of quality control. Metabolites (glucose, urea, and creatinine), lipids [triglycerides (TG), total cholesterol, high-density lipoprotein cholesterol (HDL-C)], enzymes [alkaline phosphatase (ALP), alanine aminotransferase (AST)], electrolytes (sodium, potassium, chloride) and total protein were assessed. Between-day imprecision (CVs), inaccuracy (Bias) and sigma values were calculated for each control level. Results: Apart from sodium (2.40%, 3.83%), chloride (2.52% and 2.51%) for both L1 and L2 respectively, and glucose (4.82%), cholesterol (4.86%) for L2, CVs for all other parameters (both L1 and L2) were >5%. Four parameters (HDL-C, urea, creatinine and potassium) achieved sigma levels >1 for both controls. Chloride and sodium achieved sigma levels >1 for L1 but <1 for L2. In contrast, cholesterol, total protein and AST achieved sigma levels <1 for L1 but >1 for L2. Glucose and ALP achieved a sigma level >1 for both control levels whereas TG achieved a sigma level >2 for both control levels. Conclusion: Unsatisfactory sigma levels (<3) where achieved for all parameters using both control levels, this shows instability and low consistency of results. There is the need for detailed assessment of the analytical procedures and the strengthening of the laboratory control systems in order to achieve effective six sigma levels for the laboratory. PMID:25657495

  2. Evaluation of XV-15 tilt rotor aircraft for flying qualities research application

    NASA Technical Reports Server (NTRS)

    Radford, R. C.; Schelhorn, A. E.; Siracuse, R. J.; Till, R. D.; Wasserman, R.

    1976-01-01

    The results of a design review study and evaluation of the XV-15 Tilt Rotor Research Aircraft for flying qualities research application are presented. The objectives of the program were to determine the capability of the XV-15 aircraft and the V/STOLAND system as a safe, inflight facility to provide meaningful research data on flying qualities, flight control systems, and information display systems.

  3. Quality control in diagnostic immunohistochemistry: integrated on-slide positive controls.

    PubMed

    Bragoni, A; Gambella, A; Pigozzi, S; Grigolini, M; Fiocca, R; Mastracci, L; Grillo, F

    2017-11-01

    Standardization in immunohistochemistry is a priority in modern pathology and requires strict quality control. Cost containment has also become fundamental and auditing of all procedures must take into account both these principles. Positive controls must be routinely performed so that their positivity guarantees the appropriateness of the immunohistochemical procedure. The aim of this study is to develop a low cost (utilizing a punch biopsy-PB-tool) procedure to construct positive controls which can be integrated in the patient's tissue slide. Sixteen frequently used control blocks were selected and multiple cylindrical samples were obtained using a 5-mm diameter punch biopsy tool, separately re-embedding them in single blocks. For each diagnostic immunoreaction requiring a positive control, an integrated PB-control section (cut from the appropriate PB-control block) was added to the top right corner of the diagnostic slide before immunostaining. This integrated control technique permitted a saving of 4.75% in total direct lab costs and proved to be technically feasible and reliable. Our proposal is easy to perform and within the reach of all pathology labs, requires easily available tools, its application costs is less than using external paired controls and ensures that a specific control for each slide is always available.

  4. Quality Control Analysis of Selected Aspects of Programs Administered by the Bureau of Student Financial Assistance. Error-Prone Model Derived from 1978-1979 Quality Control Study. Data Report. [Task 3.

    ERIC Educational Resources Information Center

    Saavedra, Pedro; Kuchak, JoAnn

    An error-prone model (EPM) to predict financial aid applicants who are likely to misreport on Basic Educational Opportunity Grant (BEOG) applications was developed, based on interviews conducted with a quality control sample of 1,791 students during 1978-1979. The model was designed to identify corrective methods appropriate for different types of…

  5. A New Quality Control Method base on IRMCD for Wind Profiler Observation towards Future Assimilation Application

    NASA Astrophysics Data System (ADS)

    Chen, Min; Zhang, Yu

    2017-04-01

    A wind profiler network with a total of 65 profiling radars was operated by the MOC/CMA in China until July 2015. In this study, a quality control procedure is constructed to incorporate the profiler data from the wind-profiling network into the local data assimilation and forecasting system (BJRUC). The procedure applies a blacklisting check that removes stations with gross errors and an outlier check that rejects data with large deviations from the background. Instead of the bi-weighting method, which has been commonly implemented in outlier elimination for one-dimensional scalar observations, an outlier elimination method is developed based on the iterated reweighted minimum covariance determinant (IRMCD) for multi-variate observations such as wind profiler data. A quality control experiment is separately performed for subsets containing profiler data tagged in parallel with/without rain flags at every 00UTC/12UTC from 20 June to 30 Sep 2015. From the results, we find that with the quality control, the frequency distributions of the differences between the observations and model background become more Gaussian-like and meet the requirements of a Gaussian distribution for data assimilation. Further intensive assessment for each quality control step reveals that the stations rejected by blacklisting contain poor data quality, and the IRMCD rejects outliers in a robust and physically reasonable manner.

  6. Express quality control of chicken eggs by machine vision

    NASA Astrophysics Data System (ADS)

    Gorbunova, Elena V.; Chertov, Aleksandr N.; Peretyagin, Vladimir S.; Korotaev, Valery V.; Arbuzova, Evgeniia A.

    2017-06-01

    The urgency of the task of analyzing the foodstuffs quality is determined by the strategy for the formation of a healthy lifestyle and the rational nutrition of the world population. This applies to products, such as chicken eggs. In particular, it is necessary to control the chicken eggs quality at the farm production prior to incubation in order to eliminate the possible hereditary diseases, as well as high embryonic mortality and a sharp decrease in the quality of the bred young. Up to this day, in the market there are no objective instruments of contactless express quality control as analytical equipment that allow the high-precision quality examination of the chicken eggs, which is determined by the color parameters of the eggshell (color uniformity) and yolk of eggs, and by the presence in the eggshell of various defects (cracks, growths, wrinkles, dirty). All mentioned features are usually evaluated only visually (subjectively) with the help of normalized color standards and ovoscopes. Therefore, this work is devoted to the investigation of the application opportunities of contactless express control method with the help of technical vision to implement the chicken eggs' quality analysis. As a result of the studies, a prototype with the appropriate software was proposed. Experimental studies of this equipment on a representative sample of eggs from chickens of different breeds have been carried out (the total number of analyzed samples exceeds 300 pieces). The correctness of the color analysis was verified by spectrophotometric studies of the surface of the eggshell.

  7. QUALITY CONTROL OF PHARMACEUTICALS.

    PubMed

    LEVI, L; WALKER, G C; PUGSLEY, L I

    1964-10-10

    Quality control is an essential operation of the pharmaceutical industry. Drugs must be marketed as safe and therapeutically active formulations whose performance is consistent and predictable. New and better medicinal agents are being produced at an accelerated rate. At the same time more exacting and sophisticated analytical methods are being developed for their evaluation. Requirements governing the quality control of pharmaceuticals in accordance with the Canadian Food and Drugs Act are cited and discussed.

  8. 7 CFR 58.928 - Quality control tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Quality control tests. 58.928 Section 58.928... Procedures § 58.928 Quality control tests. All dairy products and other ingredients shall be subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be...

  9. Expert database system for quality control

    NASA Astrophysics Data System (ADS)

    Wang, Anne J.; Li, Zhi-Cheng

    1993-09-01

    There are more competitors today. Markets are not homogeneous they are fragmented into increasingly focused niches requiring greater flexibility in the product mix shorter manufacturing production runs and above allhigher quality. In this paper the author identified a real-time expert system as a way to improve plantwide quality management. The quality control expert database system (QCEDS) by integrating knowledge of experts in operations quality management and computer systems use all information relevant to quality managementfacts as well as rulesto determine if a product meets quality standards. Keywords: expert system quality control data base

  10. 7 CFR 58.335 - Quality control tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Quality control tests. 58.335 Section 58.335... Procedures § 58.335 Quality control tests. All milk, cream and related products are subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be made on flow...

  11. Quality Control of Pharmaceuticals

    PubMed Central

    Levi, Leo; Walker, George C.; Pugsley, L. I.

    1964-01-01

    Quality control is an essential operation of the pharmaceutical industry. Drugs must be marketed as safe and therapeutically active formulations whose performance is consistent and predictable. New and better medicinal agents are being produced at an accelerated rate. At the same time more exacting and sophisticated analytical methods are being developed for their evaluation. Requirements governing the quality control of pharmaceuticals in accordance with the Canadian Food and Drugs Act are cited and discussed. PMID:14199105

  12. Portable Holographic Interferometry Testing System: Application to crack patching quality control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heslehurst, R.B.; Baird, J.P.; Williamson, H.M.

    Over recent years the repair of metallic structures has been improved through the use of patches fabricated from composite materials and adhesively bonded to the damaged area. This technology is termed crack patching, and has been successfully and extensively used by the RAAF and the USAF. However, application of the technology to civilian registered aircraft has had limited success due to the apparent lack of suitable quality assurance testing methods and the airworthiness regulators concern overpatch adhesion integrity. Holographic interferometry has previously shown the advantages of detecting out-of-plane deformations of the order of the wavelength of light (1{mu}). Evidence willmore » be presented that holography is able to detect changes in load path due to debonds and weakened adhesion in an adhesively bonded patch. A Portable Holographic Interferometry Testing System (PHITS) which overcomes the vibration isolation problem associated with conventional holography techniques has been developed. The application of PHITS to crack patching technology now provides a suitable method to verify the integrity of bonded patches in-situ.« less

  13. Automated, Miniaturized and Integrated Quality Control-on-Chip (QC-on-a-Chip) for Advanced Cell Therapy Applications

    NASA Astrophysics Data System (ADS)

    Wartmann, David; Rothbauer, Mario; Kuten, Olga; Barresi, Caterina; Visus, Carmen; Felzmann, Thomas; Ertl, Peter

    2015-09-01

    The combination of microfabrication-based technologies with cell biology has laid the foundation for the development of advanced in vitro diagnostic systems capable of evaluating cell cultures under defined, reproducible and standardizable measurement conditions. In the present review we describe recent lab-on-a-chip developments for cell analysis and how these methodologies could improve standard quality control in the field of manufacturing cell-based vaccines for clinical purposes. We highlight in particular the regulatory requirements for advanced cell therapy applications using as an example dendritic cell-based cancer vaccines to describe the tangible advantages of microfluidic devices that overcome most of the challenges associated with automation, miniaturization and integration of cell-based assays. As its main advantage lab-on-a-chip technology allows for precise regulation of culturing conditions, while simultaneously monitoring cell relevant parameters using embedded sensory systems. State-of-the-art lab-on-a-chip platforms for in vitro assessment of cell cultures and their potential future applications for cell therapies and cancer immunotherapy are discussed in the present review.

  14. Modal control theory and application to aircraft lateral handling qualities design

    NASA Technical Reports Server (NTRS)

    Srinathkumar, S.

    1978-01-01

    A multivariable synthesis procedure based on eigenvalue/eigenvector assignment is reviewed and is employed to develop a systematic design procedure to meet the lateral handling qualities design objectives of a fighter aircraft over a wide range of flight conditions. The closed loop modal characterization developed provides significant insight into the design process and plays a pivotal role in the synthesis of robust feedback systems. The simplicity of the synthesis algorithm yields an efficient computer aided interactive design tool for flight control system synthesis.

  15. 30 CFR 28.31 - Quality control plans; contents.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality control plans; contents. 28.31 Section... PROTECTION FOR TRAILING CABLES IN COAL MINES Quality Control § 28.31 Quality control plans; contents. (a) Each quality control plan shall contain provisions for the management of quality, including: (1...

  16. [Highly quality-controlled radiation therapy].

    PubMed

    Shirato, Hiroki

    2005-04-01

    Advanced radiation therapy for intracranial disease has focused on set-up accuracy for the past 15 years. However, quality control in the prescribed dose is actually as important as the tumor set-up in radiation therapy. Because of the complexity of the three-dimensional radiation treatment planning system in recent years, the highly quality-controlled prescription of the dose has now been reappraised as the mainstream to improve the treatment outcome of radiation therapy for intracranial disease. The Japanese Committee for Quality Control of Radiation Therapy has developed fundamental requirements such as a QC committee in each hospital, a medical physicist, dosimetrists (QC members), and an external audit.

  17. Production system with process quality control: modelling and application

    NASA Astrophysics Data System (ADS)

    Tsou, Jia-Chi

    2010-07-01

    Over the past decade, there has been a great deal of research dedicated to the study of quality and the economics of production. In this article, we develop a dynamic model which is based on the hypothesis of a traditional economic production quantity model. Taguchi's cost of poor quality is used to evaluate the cost of poor quality in the dynamic production system. A practical case from the automotive industry, which uses the Six-sigma DMAIC methodology, is discussed to verify the proposed model. This study shows that there is an optimal value of quality investment to make the production system reach a reasonable quality level and minimise the production cost. Based on our model, the management can adjust its investment in quality improvement to generate considerable financial return.

  18. Preliminary Quality Control System Design for the Pell Grant Program.

    ERIC Educational Resources Information Center

    Advanced Technology, Inc., Reston, VA.

    A preliminary design for a quality control (QC) system for the Pell Grant Program is proposed, based on the needs of the Office of Student Financial Assistance (OSFA). The applicability of the general design for other student aid programs administered by OSFA is also considered. The following steps included in a strategic approach to QC system…

  19. 78 FR 20252 - Water Quality Standards; Withdrawal of Certain Federal Water Quality Criteria Applicable to...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-04

    ... aquatic life water quality criteria applicable to waters of New Jersey, Puerto Rico, and California's San Francisco Bay. In 1992, EPA promulgated the National Toxics Rule or NTR to establish numeric water quality... Water Quality Standards; Withdrawal of Certain Federal Water Quality Criteria Applicable to California...

  20. Decision theory applied to image quality control in radiology.

    PubMed

    Lessa, Patrícia S; Caous, Cristofer A; Arantes, Paula R; Amaro, Edson; de Souza, Fernando M Campello

    2008-11-13

    The present work aims at the application of the decision theory to radiological image quality control (QC) in diagnostic routine. The main problem addressed in the framework of decision theory is to accept or reject a film lot of a radiology service. The probability of each decision of a determined set of variables was obtained from the selected films. Based on a radiology service routine a decision probability function was determined for each considered group of combination characteristics. These characteristics were related to the film quality control. These parameters were also framed in a set of 8 possibilities, resulting in 256 possible decision rules. In order to determine a general utility application function to access the decision risk, we have used a simple unique parameter called r. The payoffs chosen were: diagnostic's result (correct/incorrect), cost (high/low), and patient satisfaction (yes/no) resulting in eight possible combinations. Depending on the value of r, more or less risk will occur related to the decision-making. The utility function was evaluated in order to determine the probability of a decision. The decision was made with patients or administrators' opinions from a radiology service center. The model is a formal quantitative approach to make a decision related to the medical imaging quality, providing an instrument to discriminate what is really necessary to accept or reject a film or a film lot. The method presented herein can help to access the risk level of an incorrect radiological diagnosis decision.

  1. 30 CFR 74.6 - Quality control.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Quality control. 74.6 Section 74.6 Mineral... of the CMDPSU will be maintained in production through adequate quality control procedures, MSHA and... DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust Personal Sampler Unit § 74.6 Quality...

  2. Electronic nose for quality control of Colombian coffee through the detection of defects in "Cup Tests".

    PubMed

    Rodríguez, Juan; Durán, Cristhian; Reyes, Adriana

    2010-01-01

    Electronic noses (ENs), are used for many applications, but we must emphasize the importance of their application to foodstuffs like coffee. This paper presents a research study about the analysis of Colombian coffee samples for the detection and classification of defects (i.e., using "Cup Tests"), which was conducted at the Almacafé quality control laboratory in Cúcuta, Colombia. The results obtained show that the application of an electronic nose called "A-NOSE", may be used in the coffee industry for the cupping tests. The results show that e-nose technology can be a useful tool for quality control to evaluate the excellence of the Colombian coffee produced by National Federation of Coffee Growers.

  3. Some Inspection Methods for Quality Control and In-service Inspection of GLARE

    NASA Astrophysics Data System (ADS)

    Sinke, J.

    2003-07-01

    Quality control of materials and structures is an important issue, also for GLARE. During the manufacturing stage the processes and materials should be monitored and checked frequently in order to obtain a qualified product. During the operation of the aircraft, frequent monitoring and inspections are performed to maintain the quality at a prescribed level. Therefore, in-service inspection methods are applied, and when necessary repair activities are conducted. For the quality control of the GLARE panels and components during manufacturing, the C-scan method proves to be an effective tool. For in-service inspection the Eddy Current Method is one of the suitable options. In this paper a brief overview is presented of both methods and their application on GLARE products.

  4. Distributed sensor architecture for intelligent control that supports quality of control and quality of service.

    PubMed

    Poza-Lujan, Jose-Luis; Posadas-Yagüe, Juan-Luis; Simó-Ten, José-Enrique; Simarro, Raúl; Benet, Ginés

    2015-02-25

    This paper is part of a study of intelligent architectures for distributed control and communications systems. The study focuses on optimizing control systems by evaluating the performance of middleware through quality of service (QoS) parameters and the optimization of control using Quality of Control (QoC) parameters. The main aim of this work is to study, design, develop, and evaluate a distributed control architecture based on the Data-Distribution Service for Real-Time Systems (DDS) communication standard as proposed by the Object Management Group (OMG). As a result of the study, an architecture called Frame-Sensor-Adapter to Control (FSACtrl) has been developed. FSACtrl provides a model to implement an intelligent distributed Event-Based Control (EBC) system with support to measure QoS and QoC parameters. The novelty consists of using, simultaneously, the measured QoS and QoC parameters to make decisions about the control action with a new method called Event Based Quality Integral Cycle. To validate the architecture, the first five Braitenberg vehicles have been implemented using the FSACtrl architecture. The experimental outcomes, demonstrate the convenience of using jointly QoS and QoC parameters in distributed control systems.

  5. Distributed Sensor Architecture for Intelligent Control that Supports Quality of Control and Quality of Service

    PubMed Central

    Poza-Lujan, Jose-Luis; Posadas-Yagüe, Juan-Luis; Simó-Ten, José-Enrique; Simarro, Raúl; Benet, Ginés

    2015-01-01

    This paper is part of a study of intelligent architectures for distributed control and communications systems. The study focuses on optimizing control systems by evaluating the performance of middleware through quality of service (QoS) parameters and the optimization of control using Quality of Control (QoC) parameters. The main aim of this work is to study, design, develop, and evaluate a distributed control architecture based on the Data-Distribution Service for Real-Time Systems (DDS) communication standard as proposed by the Object Management Group (OMG). As a result of the study, an architecture called Frame-Sensor-Adapter to Control (FSACtrl) has been developed. FSACtrl provides a model to implement an intelligent distributed Event-Based Control (EBC) system with support to measure QoS and QoC parameters. The novelty consists of using, simultaneously, the measured QoS and QoC parameters to make decisions about the control action with a new method called Event Based Quality Integral Cycle. To validate the architecture, the first five Braitenberg vehicles have been implemented using the FSACtrl architecture. The experimental outcomes, demonstrate the convenience of using jointly QoS and QoC parameters in distributed control systems. PMID:25723145

  6. Quality control education in the community college

    NASA Technical Reports Server (NTRS)

    Greene, J. Griffen; Wilson, Steve

    1966-01-01

    This paper describes the Quality Control Program at Daytona Beach Junior College, including course descriptions. The program in quality control required communication between the college and the American Society for Quality Control (ASQC). The college has machinery established for certification of the learning process, and the society has the source of teachers who are competent in the technical field and who are the employers of the educational products. The associate degree for quality control does not have a fixed program, which can serve all needs, any more than all engineering degrees have identical programs. The main ideas which would be common to all quality control programs are the concept of economic control of a repetitive process and the concept of developing individual potentialities into individuals who are needed and productive.

  7. Low-Cost Quality Control and Nondestructive Evaluation Technologies for General Aviation Structures

    NASA Technical Reports Server (NTRS)

    Cramer, K. Elliott; Gavinsky, Bob; Semanskee, Grant

    1998-01-01

    NASA's Advanced General Aviation Transport Experiments (AGATE) Program has as a goal to reduce the overall cost of producing private aviation aircraft while maintaining the safety of these aircraft. In order to successfully meet this goal, it is necessary to develop nondestructive inspection techniques which will facilitate the production of the materials used in these aircraft and assure the quality necessary to maintain airworthiness. This paper will discuss a particular class of general aviation materials and several nondestructive inspection techniques that have proven effective for making these inspections. Additionally, this paper will discuss the investigation and application of other commercially available quality control techniques applicable to these structures.

  8. 23 CFR 1340.8 - Quality control.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... OBSERVATIONAL SURVEYS OF SEAT BELT USE Survey Design Requirements § 1340.8 Quality control. (a) Quality control... control monitors involved in seat belt use surveys shall have received training in data collection...) Statistical review. Survey results shall be reviewed and approved by a survey statistician, i.e., a person...

  9. 23 CFR 1340.8 - Quality control.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... OBSERVATIONAL SURVEYS OF SEAT BELT USE Survey Design Requirements § 1340.8 Quality control. (a) Quality control... control monitors involved in seat belt use surveys shall have received training in data collection...) Statistical review. Survey results shall be reviewed and approved by a survey statistician, i.e., a person...

  10. 23 CFR 1340.8 - Quality control.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... OBSERVATIONAL SURVEYS OF SEAT BELT USE Survey Design Requirements § 1340.8 Quality control. (a) Quality control... control monitors involved in seat belt use surveys shall have received training in data collection...) Statistical review. Survey results shall be reviewed and approved by a survey statistician, i.e., a person...

  11. 42 CFR 84.41 - Quality control plans; contents.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Quality control plans; contents. 84.41 Section 84... AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Quality Control § 84.41 Quality control plans; contents. (a) Each quality control plan shall contain provisions for the...

  12. 42 CFR 84.41 - Quality control plans; contents.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Quality control plans; contents. 84.41 Section 84... AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Quality Control § 84.41 Quality control plans; contents. (a) Each quality control plan shall contain provisions for the...

  13. 42 CFR 84.41 - Quality control plans; contents.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Quality control plans; contents. 84.41 Section 84... AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Quality Control § 84.41 Quality control plans; contents. (a) Each quality control plan shall contain provisions for the...

  14. 42 CFR 84.41 - Quality control plans; contents.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Quality control plans; contents. 84.41 Section 84... AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Quality Control § 84.41 Quality control plans; contents. (a) Each quality control plan shall contain provisions for the...

  15. 42 CFR 84.41 - Quality control plans; contents.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Quality control plans; contents. 84.41 Section 84... AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Quality Control § 84.41 Quality control plans; contents. (a) Each quality control plan shall contain provisions for the...

  16. Instrument Quality Control.

    PubMed

    Jayakody, Chatura; Hull-Ryde, Emily A

    2016-01-01

    Well-defined quality control (QC) processes are used to determine whether a certain procedure or action conforms to a widely accepted standard and/or set of guidelines, and are important components of any laboratory quality assurance program (Popa-Burke et al., J Biomol Screen 14: 1017-1030, 2009). In this chapter, we describe QC procedures useful for monitoring the accuracy and precision of laboratory instrumentation, most notably automated liquid dispensers. Two techniques, gravimetric QC and photometric QC, are highlighted in this chapter. When used together, these simple techniques provide a robust process for evaluating liquid handler accuracy and precision, and critically underpin high-quality research programs.

  17. 14 CFR 145.211 - Quality control system.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Quality control system. 145.211 Section 145...) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Operating Rules § 145.211 Quality control system. (a) A certificated repair station must establish and maintain a quality control system acceptable to...

  18. 14 CFR 145.211 - Quality control system.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Quality control system. 145.211 Section 145...) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Operating Rules § 145.211 Quality control system. (a) A certificated repair station must establish and maintain a quality control system acceptable to...

  19. Quality Control Review of Coopers & Lybrand L.L.P. Polytechnic University. Fiscal Year Ended June 30, 1996

    DTIC Science & Technology

    1998-05-18

    The objective of a quality control review is to assure that the audit was conducted in accordance with applicable standards and meets the auditing...requirements of the OMB Circular A-I 33. As the cognizant Federal agency for the University, we conducted a quality control review of the audit working...papers. We focused our review on the following qualitative aspects of the audit : due professional care, planning, supervision, independence, quality

  20. Can We Control Contaminant Transport In Hydrologic Networks? Application Of Control Theory Concepts To Watershed Management

    NASA Astrophysics Data System (ADS)

    Yeghiazarian, L.; Riasi, M. S.

    2016-12-01

    Although controlling the level of contamination everywhere in the surface water network may not be feasible, it is vital to maintain safe water quality levels in specific areas, e.g. recreational waters. The question then is "what is the most efficient way to fully/partially control water quality in surface water networks?". This can be posed as a control problem where the goal is to efficiently drive the system to a desired state by manipulating few input variables. Such problems reduce to (1) finding the best control locations in the network to influence the state of the system; and (2) choosing the time-variant inputs at the control locations to achieve the desired state of the system with minimum effort. We demonstrate that the optimal solution to control the level of contamination in the network can be found through application of control theory concepts to transport in dendritic surface water networks.

  1. Quality Control in construction.

    DTIC Science & Technology

    1984-01-01

    behavioral scientists. In 1962, Dr. Kaoru Ishikawa gave shape to the form of training which featured intradepartmental groups of ten or so workers seated...and Japanese circles bears closer scrutiny. 4.3.1 Japanese Ingredients of Quality The founder of quality circles, Dr. Kaoru Ishikawa , gives six...around 51 a table; hence the name Quality Control Circle. 4 Dr. 0 Ishikawa was an engineering professor at Tokyo University, and the circles were

  2. Quality Assurance and Quality Control, Part 2.

    PubMed

    Akers, Michael J

    2015-01-01

    The tragedy surrounding the New England Compounding Center and contaminated steroid syringe preparations clearly points out what can happen if quality-assurance and quality-control procedures are not strictly practiced in the compounding of sterile preparations. This article is part 2 of a two-part article on requirements to comply with United States Pharmacopeia general chapters <797> and <1163> with respect to quality assurance of compounded sterile preparations. Part 1 covered documentation requirements, inspection procedures, compounding accuracy checks, and part of a discussion on bacterial endotoxin testing. Part 2 covers sterility testing, the completion from part 1 on bacterial endotoxin testing, a brief dicussion of United States Pharmacopeia <1163>, and advances in pharmaceutical quality systems.

  3. Guidance for Efficient Small Animal Imaging Quality Control.

    PubMed

    Osborne, Dustin R; Kuntner, Claudia; Berr, Stuart; Stout, David

    2017-08-01

    Routine quality control is a critical aspect of properly maintaining high-performance small animal imaging instrumentation. A robust quality control program helps produce more reliable data both for academic purposes and as proof of system performance for contract imaging work. For preclinical imaging laboratories, the combination of costs and available resources often limits their ability to produce efficient and effective quality control programs. This work presents a series of simplified quality control procedures that are accessible to a wide range of preclinical imaging laboratories. Our intent is to provide minimum guidelines for routine quality control that can assist preclinical imaging specialists in setting up an appropriate quality control program for their facility.

  4. [Service quality in health care: the application of the results of marketing research].

    PubMed

    Verheggen, F W; Harteloh, P P

    1993-01-01

    This paper deals with quality assurance in health care and its relation to quality assurance in trade and industry. We present the service quality model--a model of quality from marketing research--and discuss how it can be applied to health care. Traditional quality assurance appears to have serious flaws. It lacks a general theory of the sources of hazards in the complex process of patient care and tends to stagnate, for no real improvement takes place. Departing from this criticism, modern quality assurance in health care is marked by: defining quality in a preferential sense as "fitness for use"; the use of theories and models of trade and industry (process-control); an emphasis on analyzing the process, instead of merely inspecting it; use of the Deming problem solving technique (plan, do, check, act); improvement of the process of care by altering perceptions of parties involved. We present an experience of application and utilization of this method in the University Hospital Maastricht, The Netherlands. The successful application of this model requires a favorable corporate culture and motivation of the health care workers. This model provides a useful framework to uplift the traditional approach to quality assurance in health care.

  5. 42 CFR 84.256 - Quality control requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Quality control requirements. 84.256 Section 84.256... § 84.256 Quality control requirements. (a) In addition to the construction and performance requirements specified in §§ 84.251, 84.252, 84.253, 84.254, and 84.255, the quality control requirements in paragraphs...

  6. 42 CFR 84.256 - Quality control requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Quality control requirements. 84.256 Section 84.256... § 84.256 Quality control requirements. (a) In addition to the construction and performance requirements specified in §§ 84.251, 84.252, 84.253, 84.254, and 84.255, the quality control requirements in paragraphs...

  7. 42 CFR 84.256 - Quality control requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Quality control requirements. 84.256 Section 84.256... § 84.256 Quality control requirements. (a) In addition to the construction and performance requirements specified in §§ 84.251, 84.252, 84.253, 84.254, and 84.255, the quality control requirements in paragraphs...

  8. 42 CFR 84.256 - Quality control requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Quality control requirements. 84.256 Section 84.256... § 84.256 Quality control requirements. (a) In addition to the construction and performance requirements specified in §§ 84.251, 84.252, 84.253, 84.254, and 84.255, the quality control requirements in paragraphs...

  9. 42 CFR 84.256 - Quality control requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Quality control requirements. 84.256 Section 84.256... § 84.256 Quality control requirements. (a) In addition to the construction and performance requirements specified in §§ 84.251, 84.252, 84.253, 84.254, and 84.255, the quality control requirements in paragraphs...

  10. QCloud: A cloud-based quality control system for mass spectrometry-based proteomics laboratories

    PubMed Central

    Chiva, Cristina; Olivella, Roger; Borràs, Eva; Espadas, Guadalupe; Pastor, Olga; Solé, Amanda

    2018-01-01

    The increasing number of biomedical and translational applications in mass spectrometry-based proteomics poses new analytical challenges and raises the need for automated quality control systems. Despite previous efforts to set standard file formats, data processing workflows and key evaluation parameters for quality control, automated quality control systems are not yet widespread among proteomics laboratories, which limits the acquisition of high-quality results, inter-laboratory comparisons and the assessment of variability of instrumental platforms. Here we present QCloud, a cloud-based system to support proteomics laboratories in daily quality assessment using a user-friendly interface, easy setup, automated data processing and archiving, and unbiased instrument evaluation. QCloud supports the most common targeted and untargeted proteomics workflows, it accepts data formats from different vendors and it enables the annotation of acquired data and reporting incidences. A complete version of the QCloud system has successfully been developed and it is now open to the proteomics community (http://qcloud.crg.eu). QCloud system is an open source project, publicly available under a Creative Commons License Attribution-ShareAlike 4.0. PMID:29324744

  11. Development and Application of the Key Technologies for the Quality Control and Inspection of National Geographical Conditions Survey Products

    NASA Astrophysics Data System (ADS)

    Zhao, Y.; Zhang, L.; Ma, W.; Zhang, P.; Zhao, T.

    2018-04-01

    The First National Geographical Condition Survey is a predecessor task to dynamically master basic situations of the nature, ecology and human activities on the earth's surface and it is the brand-new mapping geographic information engineering. In order to ensure comprehensive, real and accurate survey results and achieve the quality management target which the qualified rate is 100 % and the yield is more than 80 %, it is necessary to carry out the quality control and result inspection for national geographical conditions survey on a national scale. To ensure that achievement quality meets quality target requirements, this paper develops the key technology method of "five-in-one" quality control that is constituted by "quality control system of national geographical condition survey, quality inspection technology system, quality evaluation system, quality inspection information management system and national linked quality control institutions" by aiming at large scale, wide coverage range, more undertaking units, more management levels, technical updating, more production process and obvious regional differences in the national geographical condition survey and combining with novel achievement manifestation, complicated dependency, more special reference data, and large data size. This project fully considering the domestic and foreign related research results and production practice experience, combined with the technology development and the needs of the production, it stipulates the inspection methods and technical requirements of each stage in the quality inspection of the geographical condition survey results, and extends the traditional inspection and acceptance technology, and solves the key technologies that are badly needed in the first national geographic survey.

  12. Electronic Nose for Quality Control of Colombian Coffee through the Detection of Defects in “Cup Tests”

    PubMed Central

    Rodríguez, Juan; Durán, Cristhian; Reyes, Adriana

    2010-01-01

    Electronic noses (ENs), are used for many applications, but we must emphasize the importance of their application to foodstuffs like coffee. This paper presents a research study about the analysis of Colombian coffee samples for the detection and classification of defects (i.e., using “Cup Tests”), which was conducted at the Almacafé quality control laboratory in Cúcuta, Colombia. The results obtained show that the application of an electronic nose called “A-NOSE”, may be used in the coffee industry for the cupping tests. The results show that e-nose technology can be a useful tool for quality control to evaluate the excellence of the Colombian coffee produced by National Federation of Coffee Growers. PMID:22315525

  13. Generation of Quality Pulses for Control of Qubit/Quantum Memory Spin States: Experimental and Simulation

    DTIC Science & Technology

    2016-09-01

    TECHNICAL REPORT 3046 September 2016 GENERATION OF QUALITY PULSES FOR CONTROL OF QUBIT/QUANTUM MEMORY SPIN STATES: EXPERIMENTAL AND SIMULATION...nuclear spin states of qubits/quantum memory applicable to semiconductor, superconductor, ionic, and superconductor-ionic hybrid technologies. As the...pulse quality and need for development of single pulses with very high quality will impact directly the coherence time of the qubit/ memory , we present

  14. Spacecraft Cabin Air Quality Control and Its Application to Tight Buildings

    NASA Technical Reports Server (NTRS)

    Perry, J. L.; Graf, J. C.

    1995-01-01

    Air quality is an important consideration not only for the external environment, but also for the indoor environment. Most people spend a majority of their lives indoors and the air that they breathe is important to their physical and emotional well being. Since most modern building designs have focused on energy efficiency, less fresh air is brought from the outside. As a result, pollutants from building materials, furniture, cleaning, and cooking have no place to go. To make matters worse, most ventilation systems do not include any means for removing pollutants from the recycled air. Unfortunately, pollution at even a small level can result in eye, throat, and lung irritation in addition to chronic headaches, nausea, and fatigue. A spacecraft cabin, which represents the worst case in tight building design, requires special consideration of air quality since any effects pollutants may have on a crewmember can potentially place a mission or other crewmembers at risk. A detailed approach has been developed by the National Aeronautics and Space Administration (NASA) to minimize cabin atmosphere pollution and provide the crew with an environment which is as free of pollutants as possible. This approach is a combination of passive and active contamination control concepts involving the evaluation and selection of materials to be used onboard the spacecraft, the establishment of air quality standards to ensure crew health, and the use of active control means onboard the spacecraft to further ensure an acceptable atmosphere. This approach has allowed NASA to prevent illness by providing crewmembers with a cabin atmosphere which contains pollutant concentrations up to 100 times lower than those specified for terrestrial indoor environments. Standard building construction, however, does not take into account the potentially harmful effects of materials used in the construction process on the health of future occupants and relies primarily on remedial rather than

  15. Rapid evaluation and quality control of next generation sequencing data with FaQCs.

    PubMed

    Lo, Chien-Chi; Chain, Patrick S G

    2014-11-19

    Next generation sequencing (NGS) technologies that parallelize the sequencing process and produce thousands to millions, or even hundreds of millions of sequences in a single sequencing run, have revolutionized genomic and genetic research. Because of the vagaries of any platform's sequencing chemistry, the experimental processing, machine failure, and so on, the quality of sequencing reads is never perfect, and often declines as the read is extended. These errors invariably affect downstream analysis/application and should therefore be identified early on to mitigate any unforeseen effects. Here we present a novel FastQ Quality Control Software (FaQCs) that can rapidly process large volumes of data, and which improves upon previous solutions to monitor the quality and remove poor quality data from sequencing runs. Both the speed of processing and the memory footprint of storing all required information have been optimized via algorithmic and parallel processing solutions. The trimmed output compared side-by-side with the original data is part of the automated PDF output. We show how this tool can help data analysis by providing a few examples, including an increased percentage of reads recruited to references, improved single nucleotide polymorphism identification as well as de novo sequence assembly metrics. FaQCs combines several features of currently available applications into a single, user-friendly process, and includes additional unique capabilities such as filtering the PhiX control sequences, conversion of FASTQ formats, and multi-threading. The original data and trimmed summaries are reported within a variety of graphics and reports, providing a simple way to do data quality control and assurance.

  16. [Investigation on production process quality control of traditional Chinese medicine--Banlangen granule as an example].

    PubMed

    Tan, Manrong; Yan, Dan; Qiu, Lingling; Chen, Longhu; Yan, Yan; Jin, Cheng; Li, Hanbing; Xiao, Xiaohe

    2012-04-01

    For the quality management system of herbal medicines, intermediate and finished products it exists the " short board" effect of methodologies. Based on the concept of process control, new strategies and new methods of the production process quality control had been established with the consideration of the actual production of traditional Chinese medicine an the characteristics of Chinese medicine. Taking Banlangen granule as a practice example, which was effective and widespread application, character identification, determination of index components, chemical fingerprint and biometrics technology were sequentially used respectively to assess the quality of Banlangen herbal medicines, intermediate (water extraction and alcohol precipitation) and finished product. With the transfer rate of chemical information and biological potency as indicators, the effectiveness and transmission of the above different assessments and control methods had been researched. And ultimately, the process quality control methods of Banlangen granule, which were based on chemical composition analysis-biometric analysis, had been set up. It can not only validly solute the current status that there were many manufacturers varying quality of Banlangen granule, but also ensure and enhance its clinical efficacy. Furthermore it provided a foundation for the construction of the quality control of traditional Chinese medicine production process.

  17. Development of a portable quality control application using a tablet-type electronic device.

    PubMed

    Ono, Tomohiro; Miyabe, Yuki; Akimoto, Mami; Mukumoto, Nobutaka; Ishihara, Yoshitomo; Nakamura, Mitsuhiro; Mizowaki, Takashi

    2018-03-01

    Our aim was to develop a portable quality control (QC) application using a thermometer, a barometer, an angle gauge, and a range finder implemented in a tablet-type consumer electronic device (CED) and to assess the accuracies of the measurements made. The QC application was programmed using Java and OpenCV libraries. First, temperature and atmospheric pressure were measured over 30 days using the temperature and pressure sensors of the CED and compared with those measured by a double-tube thermometer and a digital barometer. Second, the angle gauge was developed using the accelerometer of the CED. The roll and pitch angles of the CED were measured from 0 to 90° at intervals of 10° in the clockwise (CW) and counterclockwise (CCW) directions. The values were compared with those measured by a digital angle gauge. Third, a range finder was developed using the tablet's built-in camera and image-processing capacities. Surrogate markers were detected by the camera and their positions converted to actual positions using a homographic transformation method. Fiducial markers were placed on a treatment couch and moved 100 mm in 10-mm steps in both the lateral and longitudinal directions. The values were compared with those measured by the digital output of the treatment couch. The differences between CED values and those of other devices were compared by calculating means ± standard deviations (SDs). The means ± SDs of differences in temperature and atmospheric pressure were -0.07 ± 0.25°C and 0.05 ± 0.10 hPa, respectively. The means ± SDs of the difference in angle was -0.17 ± 0.87° (0.15 ± 0.23° degrees excluding the 90° angle). The means ± SDs of distances were 0.01 ± 0.07 mm in both the lateral and longitudinal directions. Our portable QC application was accurate and may be used instead of standard measuring devices. Our portable CED is efficient and simple when used in the field of medical physics. © 2018 American Association of

  18. 7 CFR 58.928 - Quality control tests.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... quality test shall be made to determine product stability. ... 7 Agriculture 3 2013-01-01 2013-01-01 false Quality control tests. 58.928 Section 58.928... Procedures § 58.928 Quality control tests. All dairy products and other ingredients shall be subject to...

  19. 7 CFR 58.928 - Quality control tests.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... quality test shall be made to determine product stability. ... 7 Agriculture 3 2012-01-01 2012-01-01 false Quality control tests. 58.928 Section 58.928... Procedures § 58.928 Quality control tests. All dairy products and other ingredients shall be subject to...

  20. Integrated Application of Quality-by-Design Principles to Drug Product Development: A Case Study of Brivanib Alaninate Film-Coated Tablets.

    PubMed

    Badawy, Sherif I F; Narang, Ajit S; LaMarche, Keirnan R; Subramanian, Ganeshkumar A; Varia, Sailesh A; Lin, Judy; Stevens, Tim; Shah, Pankaj A

    2016-01-01

    Modern drug product development is expected to follow quality-by-design (QbD) paradigm. At the same time, although there are several issue-specific examples in the literature that demonstrate the application of QbD principles, a holistic demonstration of the application of QbD principles to drug product development and control strategy, is lacking. This article provides an integrated case study on the systematic application of QbD to product development and demonstrates the implementation of QbD concepts in the different aspects of product and process design for brivanib alaninate film-coated tablets. Using a risk-based approach, the strategy for development entailed identification of product critical quality attributes (CQAs), assessment of risks to the CQAs, and performing experiments to understand and mitigate identified risks. Quality risk assessments and design of experiments were performed to understand the quality of the input raw materials required for a robust formulation and the impact of manufacturing process parameters on CQAs. In addition to the material property and process parameter controls, the proposed control strategy includes use of process analytical technology and conventional analytical tests to control in-process material attributes and ensure quality of the final product. Copyright © 2016. Published by Elsevier Inc.

  1. 40 CFR 227.31 - Applicable marine water quality criteria.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Applicable marine water quality criteria. 227.31 Section 227.31 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) OCEAN DUMPING CRITERIA FOR THE EVALUATION OF PERMIT APPLICATIONS FOR OCEAN DUMPING OF MATERIALS Definitions § 227.31 Applicable marine water quality...

  2. 40 CFR 227.31 - Applicable marine water quality criteria.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Applicable marine water quality criteria. 227.31 Section 227.31 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) OCEAN DUMPING CRITERIA FOR THE EVALUATION OF PERMIT APPLICATIONS FOR OCEAN DUMPING OF MATERIALS Definitions § 227.31 Applicable marine water quality...

  3. Proteomics Quality Control: Quality Control Software for MaxQuant Results.

    PubMed

    Bielow, Chris; Mastrobuoni, Guido; Kempa, Stefan

    2016-03-04

    Mass spectrometry-based proteomics coupled to liquid chromatography has matured into an automatized, high-throughput technology, producing data on the scale of multiple gigabytes per instrument per day. Consequently, an automated quality control (QC) and quality analysis (QA) capable of detecting measurement bias, verifying consistency, and avoiding propagation of error is paramount for instrument operators and scientists in charge of downstream analysis. We have developed an R-based QC pipeline called Proteomics Quality Control (PTXQC) for bottom-up LC-MS data generated by the MaxQuant software pipeline. PTXQC creates a QC report containing a comprehensive and powerful set of QC metrics, augmented with automated scoring functions. The automated scores are collated to create an overview heatmap at the beginning of the report, giving valuable guidance also to nonspecialists. Our software supports a wide range of experimental designs, including stable isotope labeling by amino acids in cell culture (SILAC), tandem mass tags (TMT), and label-free data. Furthermore, we introduce new metrics to score MaxQuant's Match-between-runs (MBR) functionality by which peptide identifications can be transferred across Raw files based on accurate retention time and m/z. Last but not least, PTXQC is easy to install and use and represents the first QC software capable of processing MaxQuant result tables. PTXQC is freely available at https://github.com/cbielow/PTXQC .

  4. Microlith-Based Catalytic Reactor for Air Quality and Trace Contaminant Control Applications

    NASA Technical Reports Server (NTRS)

    Vilekar, Saurabh; Hawley, Kyle; Junaedi, Christian; Crowder, Bruce; Prada, Julian; Mastanduno, Richard; Perry, Jay L.; Kayatin, Matthew J.

    2015-01-01

    Traditionally, gaseous compounds such as methane, carbon monoxide, and trace contaminants have posed challenges for maintaining clean air in enclosed spaces such as crewed spacecraft cabins as they are hazardous to humans and are often difficult to remove by conventional adsorption technology. Catalytic oxidizers have provided a reliable and robust means of disposing of even trace levels of these compounds by converting them into carbon dioxide and water. Precision Combustion, Inc. (PCI) and NASA - Marshall (MSFC) have been developing, characterizing, and optimizing high temperature catalytic oxidizers (HTCO) based on PCI's patented Microlith® technology to meet the requirements of future extended human spaceflight explorations. Current efforts have focused on integrating the HTCO unit with a compact, simple recuperative heat exchanger to reduce the overall system size and weight while also reducing its energy requirements. Previous efforts relied on external heat exchangers to recover the waste heat and recycle it to the oxidizer to minimize the system's power requirements; however, these units contribute weight and volume burdens to the overall system. They also result in excess heat loss due to the separation of the HTCO and the heat recuperator, resulting in lower overall efficiency. Improvements in the recuperative efficiency and close coupling of HTCO and heat recuperator lead to reductions in system energy requirements and startup time. Results from testing HTCO units integrated with heat recuperators at a variety of scales for cabin air quality control and heat melt compactor applications are reported and their benefits over previous iterations of the HTCO and heat recuperator assembly are quantified in this paper.

  5. Implementation and application of moving average as continuous analytical quality control instrument demonstrated for 24 routine chemistry assays.

    PubMed

    Rossum, Huub H van; Kemperman, Hans

    2017-07-26

    General application of a moving average (MA) as continuous analytical quality control (QC) for routine chemistry assays has failed due to lack of a simple method that allows optimization of MAs. A new method was applied to optimize the MA for routine chemistry and was evaluated in daily practice as continuous analytical QC instrument. MA procedures were optimized using an MA bias detection simulation procedure. Optimization was graphically supported by bias detection curves. Next, all optimal MA procedures that contributed to the quality assurance were run for 100 consecutive days and MA alarms generated during working hours were investigated. Optimized MA procedures were applied for 24 chemistry assays. During this evaluation, 303,871 MA values and 76 MA alarms were generated. Of all alarms, 54 (71%) were generated during office hours. Of these, 41 were further investigated and were caused by ion selective electrode (ISE) failure (1), calibration failure not detected by QC due to improper QC settings (1), possible bias (significant difference with the other analyzer) (10), non-human materials analyzed (2), extreme result(s) of a single patient (2), pre-analytical error (1), no cause identified (20), and no conclusion possible (4). MA was implemented in daily practice as a continuous QC instrument for 24 routine chemistry assays. In our setup when an MA alarm required follow-up, a manageable number of MA alarms was generated that resulted in valuable MA alarms. For the management of MA alarms, several applications/requirements in the MA management software will simplify the use of MA procedures.

  6. Analysis and Application of Quality Economics Based on Input-Output

    NASA Astrophysics Data System (ADS)

    Lu, Qiang; Li, Xin

    2018-01-01

    Quality economics analysis is an important research area in the current economic frontier, which has a huge role in promoting the quality-benefit type road development in China. Through the study of quality economics analysis and application, economics of quality and quality economics management are summarized, and theoretical framework of quality economics analysis is constructed. Finally, the quality economics analysis of aerospace equipment is taken as an example to carry on the application research.

  7. 7 CFR 981.442 - Quality control.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Quality control. 981.442 Section 981.442 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Administrative Rules and Regulations § 981.442 Quality control. (a) Incoming. Pursuant to § 981.42(a), the...

  8. 7 CFR 981.442 - Quality control.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Quality control. 981.442 Section 981.442 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING AGREEMENTS... Administrative Rules and Regulations § 981.442 Quality control. (a) Incoming. Pursuant to § 981.42(a), the...

  9. 7 CFR 981.442 - Quality control.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Quality control. 981.442 Section 981.442 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Administrative Rules and Regulations § 981.442 Quality control. (a) Incoming. Pursuant to § 981.42(a), the...

  10. Generation of Quality Pulses for Control of Qubit/Quantum Memory Spin States: Experimental and Simulation

    DTIC Science & Technology

    2016-09-01

    TECHNICAL REPORT 3046 September 2016 GENERATION OF QUALITY PULSES FOR CONTROL OF QUBIT/QUANTUM MEMORY SPIN STATES: EXPERIMENTAL AND SIMULATION...control circuitry for control of electron/ nuclear spin states of qubits/quantum memory applicable to semiconductor, superconductor, ionic, and...coherence time of the qubit/ memory , we present as an example the integration of cryogenic superconductor components, including filters and

  11. Performance Characterization of a Prototype Ultra-Short Channel Monolith Catalytic Reactor for Air Quality Control Applications

    NASA Technical Reports Server (NTRS)

    Perry, J. L.; Tomes, K. M.; Roychoudhury, S.; Tatara, J. D.

    2005-01-01

    Contaminated air and process gases, whether in a crewed spacecraft cabin atmosphere, the working volume of a microgravity science or ground-based laboratory experiment facility, or the exhaust from an automobile, are pervasive problems that ultimately effect human health, performance, and well-being. The need for highly-effective, economical decontamination processes spans a wide range of terrestrial and space flight applications. Adsorption processes are used widely for process gas decontamination. Most industrial packed bed adsorption processes use activated carbon because it is cheap and highly effective. Once saturated, however, the adsorbent is a concentrated source of contaminants. Industrial applications either dump or regenerate the activated carbon. Regeneration may be accomplished in-situ or at an off-site location. In either case, concentrated contaminated waste streams must be handled appropriately to minimize environmental impact. As economic and regulatory forces drive toward minimizing waste and environmental impact, thermal catalytic oxidation is becoming more attractive. Through novel reactor and catalyst design, more complete contaminant destruction and greater resistance to poisoning can achieved leading to less waste handling, process down-time, and maintenance. Performance of a prototype thermal catalytic reactor, based on ultra-short channel monolith (USCM) catalyst substrate design, under a variety of process flow and contaminant loading conditions is discussed. The experimental results are evaluated against present and future air quality control and process gas purification processes used on board crewed spacecraft.

  12. Contributions of CCLM to advances in quality control.

    PubMed

    Kazmierczak, Steven C

    2013-01-01

    Abstract The discipline of laboratory medicine is relatively young when considered in the context of the history of medicine itself. The history of quality control, within the context of laboratory medicine, also enjoys a relatively brief, but rich history. Laboratory quality control continues to evolve along with advances in automation, measurement techniques and information technology. Clinical Chemistry and Laboratory Medicine (CCLM) has played a key role in helping disseminate information about the proper use and utility of quality control. Publication of important advances in quality control techniques and dissemination of guidelines concerned with laboratory quality control has undoubtedly helped readers of this journal keep up to date on the most recent developments in this field.

  13. Spatial Data Quality Control Procedure applied to the Okavango Basin Information System

    NASA Astrophysics Data System (ADS)

    Butchart-Kuhlmann, Daniel

    2014-05-01

    Spatial data is a powerful form of information, capable of providing information of great interest and tremendous use to a variety of users. However, much like other data representing the 'real world', precision and accuracy must be high for the results of data analysis to be deemed reliable and thus applicable to real world projects and undertakings. The spatial data quality control (QC) procedure presented here was developed as the topic of a Master's thesis, in the sphere of and using data from the Okavango Basin Information System (OBIS), itself a part of The Future Okavango (TFO) project. The aim of the QC procedure was to form the basis of a method through which to determine the quality of spatial data relevant for application to hydrological, solute, and erosion transport modelling using the Jena Adaptable Modelling System (JAMS). As such, the quality of all data present in OBIS classified under the topics of elevation, geoscientific information, or inland waters, was evaluated. Since the initial data quality has been evaluated, efforts are underway to correct the errors found, thus improving the quality of the dataset.

  14. qcML: An Exchange Format for Quality Control Metrics from Mass Spectrometry Experiments*

    PubMed Central

    Walzer, Mathias; Pernas, Lucia Espona; Nasso, Sara; Bittremieux, Wout; Nahnsen, Sven; Kelchtermans, Pieter; Pichler, Peter; van den Toorn, Henk W. P.; Staes, An; Vandenbussche, Jonathan; Mazanek, Michael; Taus, Thomas; Scheltema, Richard A.; Kelstrup, Christian D.; Gatto, Laurent; van Breukelen, Bas; Aiche, Stephan; Valkenborg, Dirk; Laukens, Kris; Lilley, Kathryn S.; Olsen, Jesper V.; Heck, Albert J. R.; Mechtler, Karl; Aebersold, Ruedi; Gevaert, Kris; Vizcaíno, Juan Antonio; Hermjakob, Henning; Kohlbacher, Oliver; Martens, Lennart

    2014-01-01

    Quality control is increasingly recognized as a crucial aspect of mass spectrometry based proteomics. Several recent papers discuss relevant parameters for quality control and present applications to extract these from the instrumental raw data. What has been missing, however, is a standard data exchange format for reporting these performance metrics. We therefore developed the qcML format, an XML-based standard that follows the design principles of the related mzML, mzIdentML, mzQuantML, and TraML standards from the HUPO-PSI (Proteomics Standards Initiative). In addition to the XML format, we also provide tools for the calculation of a wide range of quality metrics as well as a database format and interconversion tools, so that existing LIMS systems can easily add relational storage of the quality control data to their existing schema. We here describe the qcML specification, along with possible use cases and an illustrative example of the subsequent analysis possibilities. All information about qcML is available at http://code.google.com/p/qcml. PMID:24760958

  15. qcML: an exchange format for quality control metrics from mass spectrometry experiments.

    PubMed

    Walzer, Mathias; Pernas, Lucia Espona; Nasso, Sara; Bittremieux, Wout; Nahnsen, Sven; Kelchtermans, Pieter; Pichler, Peter; van den Toorn, Henk W P; Staes, An; Vandenbussche, Jonathan; Mazanek, Michael; Taus, Thomas; Scheltema, Richard A; Kelstrup, Christian D; Gatto, Laurent; van Breukelen, Bas; Aiche, Stephan; Valkenborg, Dirk; Laukens, Kris; Lilley, Kathryn S; Olsen, Jesper V; Heck, Albert J R; Mechtler, Karl; Aebersold, Ruedi; Gevaert, Kris; Vizcaíno, Juan Antonio; Hermjakob, Henning; Kohlbacher, Oliver; Martens, Lennart

    2014-08-01

    Quality control is increasingly recognized as a crucial aspect of mass spectrometry based proteomics. Several recent papers discuss relevant parameters for quality control and present applications to extract these from the instrumental raw data. What has been missing, however, is a standard data exchange format for reporting these performance metrics. We therefore developed the qcML format, an XML-based standard that follows the design principles of the related mzML, mzIdentML, mzQuantML, and TraML standards from the HUPO-PSI (Proteomics Standards Initiative). In addition to the XML format, we also provide tools for the calculation of a wide range of quality metrics as well as a database format and interconversion tools, so that existing LIMS systems can easily add relational storage of the quality control data to their existing schema. We here describe the qcML specification, along with possible use cases and an illustrative example of the subsequent analysis possibilities. All information about qcML is available at http://code.google.com/p/qcml. © 2014 by The American Society for Biochemistry and Molecular Biology, Inc.

  16. 7 CFR 58.733 - Quality control tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Quality control tests. 58.733 Section 58.733... Procedures § 58.733 Quality control tests. (a) Chemical analyses. The following chemical analyses shall be... pasteurization by means of the phosphatase test, as well as any other tests necessary to assure good quality...

  17. 7 CFR 58.733 - Quality control tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.733 Section 58.733... Procedures § 58.733 Quality control tests. (a) Chemical analyses. The following chemical analyses shall be... pasteurization by means of the phosphatase test, as well as any other tests necessary to assure good quality...

  18. Computer program CDCID: an automated quality control program using CDC update

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singer, G.L.; Aguilar, F.

    1984-04-01

    A computer program, CDCID, has been developed in coordination with a quality control program to provide a highly automated method of documenting changes to computer codes at EG and G Idaho, Inc. The method uses the standard CDC UPDATE program in such a manner that updates and their associated documentation are easily made and retrieved in various formats. The method allows each card image of a source program to point to the document which describes it, who created the card, and when it was created. The method described is applicable to the quality control of computer programs in general. Themore » computer program described is executable only on CDC computing systems, but the program could be modified and applied to any computing system with an adequate updating program.« less

  19. Quality-control design for surface-water sampling in the National Water-Quality Network

    USGS Publications Warehouse

    Riskin, Melissa L.; Reutter, David C.; Martin, Jeffrey D.; Mueller, David K.

    2018-04-10

    The data-quality objectives for samples collected at surface-water sites in the National Water-Quality Network include estimating the extent to which contamination, matrix effects, and measurement variability affect interpretation of environmental conditions. Quality-control samples provide insight into how well the samples collected at surface-water sites represent the true environmental conditions. Quality-control samples used in this program include field blanks, replicates, and field matrix spikes. This report describes the design for collection of these quality-control samples and the data management needed to properly identify these samples in the U.S. Geological Survey’s national database.

  20. Advanced strategies for quality control of Chinese medicines.

    PubMed

    Zhao, Jing; Ma, Shuang-Cheng; Li, Shao-Ping

    2018-01-05

    Quality control is always the critical issue for Chinese medicines (CMs) with their worldwide increasing use. Different from western medicine, CMs are usually considered that multiple constituents are responsible for the therapeutic effects. Therefore, quality control of CMs is a challenge. In 2011, the strategies for quantification, related to the markers, reference compounds and approaches, in quality control of CMs were reviewed (Li, et al., J. Pharm. Biomed. Anal., 2011, 55, 802-809). Since then, some new strategies have been proposed in these fields. Therefore, the review on the strategies for quality control of CMs should be updated to improve the safety and efficacy of CMs. Herein, novel strategies related to quality marker discovery, reference compound development and advanced approaches (focused on glyco-analysis) for quality control, during 2011-2016, were summarized and discussed. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Rapid evaluation and quality control of next generation sequencing data with FaQCs

    DOE PAGES

    Lo, Chien -Chi; Chain, Patrick S. G.

    2014-12-01

    Background: Next generation sequencing (NGS) technologies that parallelize the sequencing process and produce thousands to millions, or even hundreds of millions of sequences in a single sequencing run, have revolutionized genomic and genetic research. Because of the vagaries of any platform's sequencing chemistry, the experimental processing, machine failure, and so on, the quality of sequencing reads is never perfect, and often declines as the read is extended. These errors invariably affect downstream analysis/application and should therefore be identified early on to mitigate any unforeseen effects. Results: Here we present a novel FastQ Quality Control Software (FaQCs) that can rapidly processmore » large volumes of data, and which improves upon previous solutions to monitor the quality and remove poor quality data from sequencing runs. Both the speed of processing and the memory footprint of storing all required information have been optimized via algorithmic and parallel processing solutions. The trimmed output compared side-by-side with the original data is part of the automated PDF output. We show how this tool can help data analysis by providing a few examples, including an increased percentage of reads recruited to references, improved single nucleotide polymorphism identification as well as de novo sequence assembly metrics. Conclusion: FaQCs combines several features of currently available applications into a single, user-friendly process, and includes additional unique capabilities such as filtering the PhiX control sequences, conversion of FASTQ formats, and multi-threading. The original data and trimmed summaries are reported within a variety of graphics and reports, providing a simple way to do data quality control and assurance.« less

  2. 21 CFR 864.8625 - Hematology quality control mixture.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hematology quality control mixture. 864.8625 Section 864.8625 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... quality control mixture. (a) Identification. A hematology quality control mixture is a device used to...

  3. Impact of rain gauge quality control and interpolation on streamflow simulation: an application to the Warwick catchment, Australia

    NASA Astrophysics Data System (ADS)

    Liu, Shulun; Li, Yuan; Pauwels, Valentijn R. N.; Walker, Jeffrey P.

    2017-12-01

    Rain gauges are widely used to obtain temporally continuous point rainfall records, which are then interpolated into spatially continuous data to force hydrological models. However, rainfall measurements and interpolation procedure are subject to various uncertainties, which can be reduced by applying quality control and selecting appropriate spatial interpolation approaches. Consequently, the integrated impact of rainfall quality control and interpolation on streamflow simulation has attracted increased attention but not been fully addressed. This study applies a quality control procedure to the hourly rainfall measurements obtained in the Warwick catchment in eastern Australia. The grid-based daily precipitation from the Australian Water Availability Project was used as a reference. The Pearson correlation coefficient between the daily accumulation of gauged rainfall and the reference data was used to eliminate gauges with significant quality issues. The unrealistic outliers were censored based on a comparison between gauged rainfall and the reference. Four interpolation methods, including the inverse distance weighting (IDW), nearest neighbors (NN), linear spline (LN), and ordinary Kriging (OK), were implemented. The four methods were firstly assessed through a cross-validation using the quality-controlled rainfall data. The impacts of the quality control and interpolation on streamflow simulation were then evaluated through a semi-distributed hydrological model. The results showed that the Nash–Sutcliffe model efficiency coefficient (NSE) and Bias of the streamflow simulations were significantly improved after quality control. In the cross-validation, the IDW and OK methods resulted in good interpolation rainfall, while the NN led to the worst result. In term of the impact on hydrological prediction, the IDW led to the most consistent streamflow predictions with the observations, according to the validation at five streamflow-gauged locations. The OK method

  4. Impact of rain gauge quality control and interpolation on streamflow simulation: an application to the Warwick catchment, Australia

    NASA Astrophysics Data System (ADS)

    Liu, Shulun; Li, Yuan; Pauwels, Valentijn R. N.; Walker, Jeffrey P.

    2018-01-01

    Rain gauges are widely used to obtain temporally continuous point rainfall records, which are then interpolated into spatially continuous data to force hydrological models. However, rainfall measurements and interpolation procedure are subject to various uncertainties, which can be reduced by applying quality control and selecting appropriate spatial interpolation approaches. Consequently, the integrated impact of rainfall quality control and interpolation on streamflow simulation has attracted increased attention but not been fully addressed. This study applies a quality control procedure to the hourly rainfall measurements obtained in the Warwick catchment in eastern Australia. The grid-based daily precipitation from the Australian Water Availability Project was used as a reference. The Pearson correlation coefficient between the daily accumulation of gauged rainfall and the reference data was used to eliminate gauges with significant quality issues. The unrealistic outliers were censored based on a comparison between gauged rainfall and the reference. Four interpolation methods, including the inverse distance weighting (IDW), nearest neighbors (NN), linear spline (LN), and ordinary Kriging (OK), were implemented. The four methods were firstly assessed through a cross-validation using the quality-controlled rainfall data. The impacts of the quality control and interpolation on streamflow simulation were then evaluated through a semi-distributed hydrological model. The results showed that the Nash–Sutcliffe model efficiency coefficient (NSE) and Bias of the streamflow simulations were significantly improved after quality control. In the cross-validation, the IDW and OK methods resulted in good interpolation rainfall, while the NN led to the worst result. In term of the impact on hydrological prediction, the IDW led to the most consistent streamflow predictions with the observations, according to the validation at five streamflow-gauged locations. The OK method

  5. Cellular Strategies of Protein Quality Control

    PubMed Central

    Chen, Bryan; Retzlaff, Marco; Roos, Thomas; Frydman, Judith

    2011-01-01

    Eukaryotic cells must contend with a continuous stream of misfolded proteins that compromise the cellular protein homeostasis balance and jeopardize cell viability. An elaborate network of molecular chaperones and protein degradation factors continually monitor and maintain the integrity of the proteome. Cellular protein quality control relies on three distinct yet interconnected strategies whereby misfolded proteins can either be refolded, degraded, or delivered to distinct quality control compartments that sequester potentially harmful misfolded species. Molecular chaperones play a critical role in determining the fate of misfolded proteins in the cell. Here, we discuss the spatial and temporal organization of cellular quality control strategies and their implications for human diseases linked to protein misfolding and aggregation. PMID:21746797

  6. 21 CFR 211.22 - Responsibilities of quality control unit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 4 2011-04-01 2011-04-01 false Responsibilities of quality control unit. 211.22... Personnel § 211.22 Responsibilities of quality control unit. (a) There shall be a quality control unit that... have been fully investigated. The quality control unit shall be responsible for approving or rejecting...

  7. 21 CFR 211.22 - Responsibilities of quality control unit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Responsibilities of quality control unit. 211.22... Personnel § 211.22 Responsibilities of quality control unit. (a) There shall be a quality control unit that... have been fully investigated. The quality control unit shall be responsible for approving or rejecting...

  8. 40 CFR 81.112 - Charleston Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Regions § 81.112 Charleston Intrastate Air Quality Control Region. The Charleston Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... Quality Control Region: Region 1. 81.107Greenwood Intrastate Air Quality Control Region: Region 2. 81...

  9. 40 CFR 81.112 - Charleston Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Regions § 81.112 Charleston Intrastate Air Quality Control Region. The Charleston Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... Quality Control Region: Region 1. 81.107Greenwood Intrastate Air Quality Control Region: Region 2. 81...

  10. Current status of postnatal depression smartphone applications available on application stores: an information quality analysis.

    PubMed

    Zhang, Melvyn Wb; Ho, Roger Cm; Loh, Alvona; Wing, Tracey; Wynne, Olivia; Chan, Sally Wai Chi; Car, Josip; Fung, Daniel Shuen Sheng

    2017-11-14

    It is the aim of the current research to identify some common functionalities of postnatal application, and to determine the quality of the information content of postnatal depression application using validated scales that have been applied for applications in other specialties. To determine the information quality of the postnatal depression smartphone applications, the two most widely used smartphone application stores, namely Apple iTunes as well as Google Android Play store, were searched between 20May and 31 May. No participants were involved. The inclusion criteria for the application were that it must have been searchable using the keywords 'postnatal', 'pregnancy', 'perinatal', 'postpartum' and 'depression', and must be in English language. The Silberg Scale was used in the assessment of the information quality of the smartphone applications. The information quality score was the primary outcome measure. Our current results highlighted that while there is currently a myriad of applications, only 14 applications are specifically focused on postnatal depression. In addition, the majority of the currently available applications on the store have only disclosed their last date of modification as well as ownership. There remain very limited disclosures about the information of the authors, as well as the references for the information included in the application itself. The average score for the Silberg Scale for the postnatal applications we have analysed is 3.0. There remains a need for healthcare professionals and developers to jointly conceptualise new applications with better information quality and evidence base. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  11. 7 CFR 275.21 - Quality control review reports.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 4 2011-01-01 2011-01-01 false Quality control review reports. 275.21 Section 275.21... Reporting on Program Performance § 275.21 Quality control review reports. (a) General. Each State agency shall submit reports on the performance of quality control reviews in accordance with the requirements...

  12. Quality Assurance Project Plan for Closure of the Central Facilities Area Sewage Treatment Plant Lagoon 3 and Land Application Area

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, Michael G.

    This quality assurance project plan describes the technical requirements and quality assurance activities of the environmental data collection/analyses operations to close Central Facilities Area Sewage treatment Plant Lagoon 3 and the land application area. It describes the organization and persons involved, the data quality objectives, the analytical procedures, and the specific quality control measures to be employed. All quality assurance project plan activities are implemented to determine whether the results of the sampling and monitoring performed are of the right type, quantity, and quality to satisfy the requirements for closing Lagoon 3 and the land application area.

  13. Extended Editorial: Research and Education in Reliability, Maintenance, Quality Control, Risk and Safety.

    ERIC Educational Resources Information Center

    Ramalhoto, M. F.

    1999-01-01

    Introduces a special theme journal issue on research and education in quality control, maintenance, reliability, risk analysis, and safety. Discusses each of these theme concepts and their applications to naval architecture, marine engineering, and industrial engineering. Considers the effects of the rapid transfer of research results through…

  14. 40 CFR 81.88 - Billings Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Regions § 81.88 Billings Intrastate Air Quality Control Region. The Metropolitan Billings Intrastate Air Quality Control Region (Montana) has been renamed the Billings Intrastate Air Quality Control... to by Montana authorities as follows: Sec. 481.168Great Falls Intrastate Air Quality Control Region...

  15. 40 CFR 81.88 - Billings Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Regions § 81.88 Billings Intrastate Air Quality Control Region. The Metropolitan Billings Intrastate Air Quality Control Region (Montana) has been renamed the Billings Intrastate Air Quality Control... to by Montana authorities as follows: Sec. 481.168Great Falls Intrastate Air Quality Control Region...

  16. Effectiveness of Positive Thinking Training Program on Nurses' Quality of Work Life through Smartphone Applications

    PubMed Central

    Dehghan, Azizallah

    2017-01-01

    Aim Job stress is a part of nurses' professional life that causes the decrease of the nurses' job satisfaction and quality of work life. This study aimed to determine the effect of positive thinking via social media applications on the nurses' quality of work life. Methods This was a pretest-posttest quasi-experimental study design with a control group. The samples were selected among the nurses in two hospitals in Fasa University of Medical Sciences and divided randomly into two interventional (n = 50) and control (n = 50) groups. Positive thinking training through telegrams was sent to the intervention group during a period of 3 months. Data were collected by using Brooks and Anderson's questionnaire of work life quality and analyzed by SPSS 18. Results The mean total scores of pretest and posttest in the intervention group improved noticeably and there were significant differences between mean scores of quality of work life in pretest and posttest scores in interventional groups (p < 0.001) and in dimensions of work life quality, home life (p < 0.001), work design (p < 0.001), work context (p < 0.001), and work world (p = 0.003). Conclusion This study concluded that positive thinking training via social media application enhanced nurses' quality of work life. This study is necessary to carry out on a larger sample size for generalizing findings better. PMID:28589174

  17. Effectiveness of Positive Thinking Training Program on Nurses' Quality of Work Life through Smartphone Applications.

    PubMed

    Motamed-Jahromi, Mohadeseh; Fereidouni, Zhila; Dehghan, Azizallah

    2017-01-01

    Job stress is a part of nurses' professional life that causes the decrease of the nurses' job satisfaction and quality of work life. This study aimed to determine the effect of positive thinking via social media applications on the nurses' quality of work life. This was a pretest-posttest quasi-experimental study design with a control group. The samples were selected among the nurses in two hospitals in Fasa University of Medical Sciences and divided randomly into two interventional ( n = 50) and control ( n = 50) groups. Positive thinking training through telegrams was sent to the intervention group during a period of 3 months. Data were collected by using Brooks and Anderson's questionnaire of work life quality and analyzed by SPSS 18. The mean total scores of pretest and posttest in the intervention group improved noticeably and there were significant differences between mean scores of quality of work life in pretest and posttest scores in interventional groups ( p < 0.001) and in dimensions of work life quality, home life ( p < 0.001), work design ( p < 0.001), work context ( p < 0.001), and work world ( p = 0.003). This study concluded that positive thinking training via social media application enhanced nurses' quality of work life. This study is necessary to carry out on a larger sample size for generalizing findings better.

  18. Data quality control in eco-environmental monitoring

    NASA Astrophysics Data System (ADS)

    Lu, Chunyan; Wang, Jing

    2007-11-01

    With the development of science and technology, a number of environmental issues, such as sustainable development, climate change, environmental pollution, and land degradation become serious. Greater attention has been attached to environmental protection. The government gradually launched some eco--environmental construction projects. In 1999, China begin to carry out the project of Grain-for-Green in the west, to improve the eco-environment, and it make some good effect, but there are some questions that still can not be answered. How about the new grass or forest? Where are they? How can we do in the future? To answer these questions, the government began to monitor the eco-environment, based on remote sensing technology. Geography information can be attained timely, but the issue of uncertainty has become increasingly recognized, and this uncertainty affects the reliability of applications using the data. This article analyzed the process of eco-environment monitoring, the uncertainty of geography information, and discussed the methods of data quality control. The Spot5 span data and multi-spectral data in 2003(2002) were used, combined with land use survey data at the scale of 1:10,000, topography data at the scale of 1:10,000, and the local Grain-for-Green project map. Also the social and economic data were collected. Eco-environmental monitoring is a process which consists of several steps, such as image geometric correction, image matching, information extraction, and so on. Based on visual and automated method, land information turned to grass and forest from cultivated land was obtained by comparing the information form remote sensing data with the land survey data, and local Grain-for-Green project data, combined with field survey. According to the process, the uncertainty in the process was analyzed. Positional uncertainty, attribute uncertainty, and thematic uncertainty was obvious. Positional uncertainty mainly derived from image geometric correction

  19. Comparative mass spectrometry & nuclear magnetic resonance metabolomic approaches for nutraceuticals quality control analysis: a brief review.

    PubMed

    Farag, Mohamed A

    2014-01-01

    The number of botanical dietary supplements in the market has recently increased primarily due to increased health awareness. Standardization and quality control of the constituents of these plant extracts is an important topic, particularly when such ingredients are used long term as dietary supplements, or in cases where higher doses are marketed as drugs. The development of fast, comprehensive, and effective untargeted analytical methods for plant extracts is of high interest. Nuclear magnetic resonance spectroscopy and mass spectrometry are the most informative tools, each of which enables high-throughput and global analysis of hundreds of metabolites in a single step. Although only one of the two techniques is utilized in the majority of plant metabolomics applications, there is a growing interest in combining the data from both platforms to effectively unravel the complexity of plant samples. The application of combined MS and NMR in the quality control of nutraceuticals forms the major part of this review. Finally I will look at the future developments and perspectives of these two technologies for the quality control of herbal materials.

  20. SIMBAD quality-control

    NASA Technical Reports Server (NTRS)

    Lesteven, Soizick

    1992-01-01

    The astronomical database SIMBAD developed at the Centre de donnees astronomiques de Strasbourg presently contains 760,000 objects (stellar and non-stellar). It has the unique characteristic of being structured specifically for astronomical objects. All types of heterogeneous data (bibliographic references, measurements, and sets of identification) are connected with each object. The attributes that define quality of the database include the following. Reliability: cross-identification should not rely upon just exact values object coordinates. It also means that information attached to one simple object should be consistent. The existing data must be controlled in order to start with a reliable base and to cross-identify new data assuring the quality as data grows. Exhaustivity: delays between publication of new informations and their inclusion in the database should be as short as possible. The integrity of the database has to be maintained as data accumulates. Taking the amount of data into consideration and the rate of new data production, it is necessary to use automatic methods. One of the possibilities is to use multivariate data analysis. The factor-space is a n-dimensional relevancy space which is described by the n-axes representing a set of n subject matter headings; the words and phrases can be used to scale the axes and the documents are then a vector average of the terms within them. The application reported herein is based on the NASA-STI bibliographical database. The selected data concern astronomy, astrophysics, and space radiation (102,963 references from 1975 to 1991 included 8070 keywords). The F-space is built from this bibliographical data. By comparing the F-space position obtained from the NASA-STI keywords with the F-space position obtained from the SIMBAD references, the authors will be able to show whether it is possible to retrieve information with a restricted set of words only. If the comparison is valid, this will be a way to enter

  1. 7 CFR 58.141 - Alternate quality control program.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Alternate quality control program. 58.141 Section 58... Service 1 Quality Specifications for Raw Milk § 58.141 Alternate quality control program. When a plant has in operation an acceptable quality program, at the producer level, which is approved by the...

  2. 21 CFR 111.105 - What must quality control personnel do?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 2 2011-04-01 2011-04-01 false What must quality control personnel do? 111.105... for Quality Control § 111.105 What must quality control personnel do? Quality control personnel must... manufacturing record. To do so, quality control personnel must perform operations that include: (a) Approving or...

  3. Theoretical approach to society-wide environmental quality control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ayano, K.

    1982-01-01

    The study outlines the basis for a theory of societal control of environmental quality in the US based on the concepts and philosophy of company-wide quality control which has developed in Japan as a cross-disciplinary approach to problem-solving in the industrial realm. The basic concepts are: 1) every member of society, as a producer of environmental products and services for future generations, in principle has the responsibility to control the quality of his output; 2) environment quality is the quality of life, or the fitness of use of environment for humans; and 3) societal control is any activity necessary formore » quality production of environmental products and services continuously or in the long run. A motivator-hygiene theory of environmental quality is identified, and a proposal is made that the policy provision must be formulated differently between those aimed at hygiene factors of environmental quality and those aimed at motivators, the former in a collectivistic manner, the latter as an individual problem. The concept of societal cost of environmental quality is introduced. Based on the motivator-hygiene theory of environmental quality, the collectivistic and individual approaches are differentiated and discussed.« less

  4. Application of visible/near infrared spectroscopy to quality control of fresh fruits and vegetables in large-scale mass distribution channels: a preliminary test on carrots and tomatoes.

    PubMed

    Beghi, Roberto; Giovenzana, Valentina; Tugnolo, Alessio; Guidetti, Riccardo

    2018-05-01

    The market for fruits and vegetables is mainly controlled by the mass distribution channel (MDC). MDC buyers do not have useful instruments to rapidly evaluate the quality of the products. Decisions by the buyers are driven primarily by pricing strategies rather than product quality. Simple, rapid and easy-to-use methods for objectively evaluating the quality of postharvest products are needed. The present study aimed to use visible and near-infrared (vis/NIR) spectroscopy to estimate some qualitative parameters of two low-price products (carrots and tomatoes) of various brands, as well as evaluate the applicability of this technique for use in stores. A non-destructive optical system (vis/NIR spectrophotometer with a reflection probe, spectral range 450-1650 nm) was tested. The differences in quality among carrots and tomatoes purchased from 13 stores on various dates were examined. The reference quality parameters (firmness, water content, soluble solids content, pH and colour) were correlated with the spectral readings. The models derived from the optical data gave positive results, in particular for the prediction of the soluble solids content and the colour, with better results for tomatoes than for carrots. The application of optical techniques may help MDC buyers to monitor the quality of postharvest products, leading to an effective optimization of the entire supply chain. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  5. Quality assurance and control issues for HF radar wave and current measurements

    NASA Astrophysics Data System (ADS)

    Wyatt, Lucy

    2015-04-01

    HF radars are now widely used to provide surface current measurements over wide areas of the coastal ocean for scientific and operational applications. In general data quality is acceptable for these applications but there remain issues that impact on the quantity and quality of the data. These include problems with calibration and interference which impact on both phased array (e.g. WERA, Pisces) and direction-finding (e.g. SeaSonde) radars. These same issues and others (e.g. signal-to-noise, in-cell current variability, antenna sidelobes) also impact on the quality and quantity of wave data that can be obtained. These issues will be discussed in this paper, illustrated with examples from deployments of WERA, Pisces and SeaSonde radars in the UK, Europe, USA and Australia. These issues involve both quality assurance (making sure the radars perform to spec and the software is fully operational) and in quality control (identifying problems with the data due to radar hardware or software performance issues and flagging these in the provided data streams). Recommendations for the former, and current practice (of the author and within the Australian Coastal Ocean Radar Network, ACORN*) for the latter, will be discussed. The quality control processes for wave measurement are not yet as well developed as those for currents and data from some deployments can be rather noisy. Some new methods, currently under development by SeaView Sensing Ltd and being tested with ACORN data, will be described and results presented. *ACORN is a facility of the Australian Integrated Marine Observing System, IMOS. IMOS is a national collaborative research infrastructure, supported by Australian Government. It is led by University of Tasmania in partnership with the Australian marine and climate science community.

  6. Quality Control in Higher Education.

    ERIC Educational Resources Information Center

    Hogarth, Charles P.

    The status of quality control in U.S. higher education is discussed with an overview of the functions and structure of public and private colleges and universities. The book is divided into seven chapters: (1) outside controls (accrediting groups, governmental groups and other groups); (2) structure (board of control, president, organization); (3)…

  7. Quality Control Review of Office of the State Auditor Mississippi State University Fiscal Year Ended June 30, 1996

    DTIC Science & Technology

    1998-04-10

    The objective of a quality control review is to ensure that the audit was conducted in accordance with applicable standards and meets the auditing requirements of the 0MB Circular A-i 33. As a Federal finding agency for the University, we conducted a quality control review of the audit working papers. We focused our review on the following qualitative aspects of the audit : due professional

  8. Quality Control Technician.

    ERIC Educational Resources Information Center

    Ohio State Univ., Columbus. Center on Education and Training for Employment.

    This document contains 18 units to consider for use in a tech prep competency profile for the occupation of quality control technician. All the units listed will not necessarily apply to every situation or tech prep consortium, nor will all the competencies within each unit be appropriate. Several units appear within each specific occupation and…

  9. Different micromanipulation applications based on common modular control architecture

    NASA Astrophysics Data System (ADS)

    Sipola, Risto; Vallius, Tero; Pudas, Marko; Röning, Juha

    2010-01-01

    This paper validates a previously introduced scalable modular control architecture and shows how it can be used to implement research equipment. The validation is conducted by presenting different kinds of micromanipulation applications that use the architecture. Conditions of the micro-world are very different from those of the macro-world. Adhesive forces are significant compared to gravitational forces when micro-scale objects are manipulated. Manipulation is mainly conducted by automatic control relying on haptic feedback provided by force sensors. The validated architecture is a hierarchical layered hybrid architecture, including a reactive layer and a planner layer. The implementation of the architecture is modular, and the architecture has a lot in common with open architectures. Further, the architecture is extensible, scalable, portable and it enables reuse of modules. These are the qualities that we validate in this paper. To demonstrate the claimed features, we present different applications that require special control in micrometer, millimeter and centimeter scales. These applications include a device that measures cell adhesion, a device that examines properties of thin films, a device that measures adhesion of micro fibers and a device that examines properties of submerged gel produced by bacteria. Finally, we analyze how the architecture is used in these applications.

  10. 40 CFR 81.77 - Puerto Rico Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 17 2011-07-01 2011-07-01 false Puerto Rico Air Quality Control Region... PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.77 Puerto Rico Air Quality Control Region. The Puerto Rico Air Quality Control Region...

  11. 40 CFR 81.77 - Puerto Rico Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Puerto Rico Air Quality Control Region... PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.77 Puerto Rico Air Quality Control Region. The Puerto Rico Air Quality Control Region...

  12. 40 CFR 81.77 - Puerto Rico Air Quality Control Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 18 2012-07-01 2012-07-01 false Puerto Rico Air Quality Control Region... PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.77 Puerto Rico Air Quality Control Region. The Puerto Rico Air Quality Control Region...

  13. 40 CFR 81.77 - Puerto Rico Air Quality Control Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 18 2013-07-01 2013-07-01 false Puerto Rico Air Quality Control Region... PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.77 Puerto Rico Air Quality Control Region. The Puerto Rico Air Quality Control Region...

  14. 21 CFR 111.105 - What must quality control personnel do?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What must quality control personnel do? 111.105..., LABELING, OR HOLDING OPERATIONS FOR DIETARY SUPPLEMENTS Production and Process Control System: Requirements for Quality Control § 111.105 What must quality control personnel do? Quality control personnel must...

  15. [Construction of NIRS-based total quality control system for compound Ejiao oral liquid and relative thinking].

    PubMed

    Zhang, Yan; Zhang, Lu; Tian, Shou-Sheng; Zhou, Xiang-Shan; Li, Wen-Long; Qu, Hai-Bin

    2016-10-01

    In this paper, near infrared spectroscopy (NIRS)-based total quality control system of compound Ejiao oral liquid is introduced briefly, including the quality control of raw traditional Chinese medicine (TCM) materials, monitoring and control of the extract and the alkaline precipitation technics, and also the inspection of finished products in both open bottle and non-opening modes. By analyzing and summing up the significance and difficulties, several important problems in the practical applications of NIRS technology are proposed, which will provide references for the similar studies of other TCM products. Copyright© by the Chinese Pharmaceutical Association.

  16. Integrity Model Application: A Quality Support System for Decision-makers on Water Quality Assessment and Improvement

    NASA Astrophysics Data System (ADS)

    Mirauda, D.; Ostoich, M.; Di Maria, F.; Benacchio, S.; Saccardo, I.

    2018-03-01

    In this paper, a mathematical model has been applied to a river in North-East Italy to describe vulnerability scenarios due to environmental pollution phenomena. Such model, based on the influence diagrams theory, allowed identifying the extremely critical factors, such as wastewater discharges, drainage of diffuse pollution from agriculture and climate changes, which might affect the water quality of the river. The obtained results underlined how the water quality conditions have improved thanks to the continuous controls on the territory, following the application of Water Framework Directive 2000/60/EC. Nevertheless, some fluvial stretches did not reach the “good ecological status” by 2015, because of the increasing population in urban areas recorded in the last years and the high presence of tourists during the summer months, not balanced by a treatment plants upgrade.

  17. Application of QC_DR software for acceptance testing and routine quality control of direct digital radiography systems: initial experiences using the Italian Association of Physicist in Medicine quality control protocol.

    PubMed

    Nitrosi, Andrea; Bertolini, Marco; Borasi, Giovanni; Botti, Andrea; Barani, Adriana; Rivetti, Stefano; Pierotti, Luisa

    2009-12-01

    Ideally, medical x-ray imaging systems should be designed to deliver maximum image quality at an acceptable radiation risk to the patient. Quality assurance procedures are employed to ensure that these standards are maintained. A quality control protocol for direct digital radiography (DDR) systems is described and discussed. Software to automatically process and analyze the required images was developed. In this paper, the initial results obtained on equipment of different DDR manufacturers were reported. The protocol was developed to highlight even small discrepancies in standard operating performance.

  18. A Total Quality-Control Plan with Right-Sized Statistical Quality-Control.

    PubMed

    Westgard, James O

    2017-03-01

    A new Clinical Laboratory Improvement Amendments option for risk-based quality-control (QC) plans became effective in January, 2016. Called an Individualized QC Plan, this option requires the laboratory to perform a risk assessment, develop a QC plan, and implement a QC program to monitor ongoing performance of the QC plan. Difficulties in performing a risk assessment may limit validity of an Individualized QC Plan. A better alternative is to develop a Total QC Plan including a right-sized statistical QC procedure to detect medically important errors. Westgard Sigma Rules provides a simple way to select the right control rules and the right number of control measurements. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. 46 CFR 164.019-13 - Production quality control requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Production quality control requirements. 164.019-13....019-13 Production quality control requirements. (a) General. Each component manufacturer shall establish procedures for maintaining quality control of the materials used in production, manufacturing...

  20. 46 CFR 164.019-13 - Production quality control requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 6 2012-10-01 2012-10-01 false Production quality control requirements. 164.019-13....019-13 Production quality control requirements. (a) General. Each component manufacturer shall establish procedures for maintaining quality control of the materials used in production, manufacturing...

  1. 46 CFR 164.019-13 - Production quality control requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Production quality control requirements. 164.019-13....019-13 Production quality control requirements. (a) General. Each component manufacturer shall establish procedures for maintaining quality control of the materials used in production, manufacturing...

  2. 46 CFR 164.019-13 - Production quality control requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 6 2014-10-01 2014-10-01 false Production quality control requirements. 164.019-13....019-13 Production quality control requirements. (a) General. Each component manufacturer shall establish procedures for maintaining quality control of the materials used in production, manufacturing...

  3. 46 CFR 164.019-13 - Production quality control requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 6 2013-10-01 2013-10-01 false Production quality control requirements. 164.019-13....019-13 Production quality control requirements. (a) General. Each component manufacturer shall establish procedures for maintaining quality control of the materials used in production, manufacturing...

  4. PACS quality control and automatic problem notifier

    NASA Astrophysics Data System (ADS)

    Honeyman-Buck, Janice C.; Jones, Douglas; Frost, Meryll M.; Staab, Edward V.

    1997-05-01

    One side effect of installing a clinical PACS Is that users become dependent upon the technology and in some cases it can be very difficult to revert back to a film based system if components fail. The nature of system failures range from slow deterioration of function as seen in the loss of monitor luminance through sudden catastrophic loss of the entire PACS networks. This paper describes the quality control procedures in place at the University of Florida and the automatic notification system that alerts PACS personnel when a failure has happened or is anticipated. The goal is to recover from a failure with a minimum of downtime and no data loss. Routine quality control is practiced on all aspects of PACS, from acquisition, through network routing, through display, and including archiving. Whenever possible, the system components perform self and between platform checks for active processes, file system status, errors in log files, and system uptime. When an error is detected or a exception occurs, an automatic page is sent to a pager with a diagnostic code. Documentation on each code, trouble shooting procedures, and repairs are kept on an intranet server accessible only to people involved in maintaining the PACS. In addition to the automatic paging system for error conditions, acquisition is assured by an automatic fax report sent on a daily basis to all technologists acquiring PACS images to be used as a cross check that all studies are archived prior to being removed from the acquisition systems. Daily quality control is preformed to assure that studies can be moved from each acquisition and contrast adjustment. The results of selected quality control reports will be presented. The intranet documentation server will be described with the automatic pager system. Monitor quality control reports will be described and the cost of quality control will be quantified. As PACS is accepted as a clinical tool, the same standards of quality control must be established

  5. Analytical approaches to quality assurance and quality control in rangeland monitoring data

    USDA-ARS?s Scientific Manuscript database

    Producing quality data to support land management decisions is the goal of every rangeland monitoring program. However, the results of quality assurance (QA) and quality control (QC) efforts to improve data quality are rarely reported. The purpose of QA and QC is to prevent and describe non-sampling...

  6. Professional Development for Water Quality Control Personnel.

    ERIC Educational Resources Information Center

    Shepard, Clinton Lewis

    This study investigated the availability of professional development opportunities for water quality control personnel in the midwest. The major objective of the study was to establish a listing of educational opportunities for the professional development of water quality control personnel and to compare these with the opportunities technicians…

  7. Effects of pesticides aerial applications on rice quality

    USDA-ARS?s Scientific Manuscript database

    Aerial application of pesticides has become an important research topic in recent years. This research investigated the effects of two types of commercial pesticides on the rice quality under low volume aerial application. It could provide guidance for the pesticide application and choose the right ...

  8. Ride quality sensitivity to SAS control law and to handling quality variations

    NASA Technical Reports Server (NTRS)

    Roberts, P. A.; Schmidt, D. K.; Swaim, R. L.

    1976-01-01

    The RQ trends which large flexible aircraft exhibit under various parameterizations of control laws and handling qualities are discussed. A summary of the assumptions and solution technique, a control law parameterization review, a discussion of ride sensitivity to handling qualities, and the RQ effects generated by implementing relaxed static stability configurations are included.

  9. 14 CFR 21.147 - Changes in quality control system.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Changes in quality control system. 21.147 Section 21.147 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... quality control system. After the issue of a production certificate, each change to the quality control...

  10. 14 CFR 21.147 - Changes in quality control system.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Changes in quality control system. 21.147 Section 21.147 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... quality control system. After the issue of a production certificate, each change to the quality control...

  11. 21 CFR 111.117 - What quality control operations are required for equipment, instruments, and controls?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What quality control operations are required for equipment, instruments, and controls? 111.117 Section 111.117 Food and Drugs FOOD AND DRUG ADMINISTRATION... and Process Control System: Requirements for Quality Control § 111.117 What quality control operations...

  12. WELDSMART: A vision-based expert system for quality control

    NASA Technical Reports Server (NTRS)

    Andersen, Kristinn; Barnett, Robert Joel; Springfield, James F.; Cook, George E.

    1992-01-01

    This work was aimed at exploring means for utilizing computer technology in quality inspection and evaluation. Inspection of metallic welds was selected as the main application for this development and primary emphasis was placed on visual inspection, as opposed to other inspection methods, such as radiographic techniques. Emphasis was placed on methodologies with the potential for use in real-time quality control systems. Because quality evaluation is somewhat subjective, despite various efforts to classify discontinuities and standardize inspection methods, the task of using a computer for both inspection and evaluation was not trivial. The work started out with a review of the various inspection techniques that are used for quality control in welding. Among other observations from this review was the finding that most weld defects result in abnormalities that may be seen by visual inspection. This supports the approach of emphasizing visual inspection for this work. Quality control consists of two phases: (1) identification of weld discontinuities (some of which may be severe enough to be classified as defects), and (2) assessment or evaluation of the weld based on the observed discontinuities. Usually the latter phase results in a pass/fail judgement for the inspected piece. It is the conclusion of this work that the first of the above tasks, identification of discontinuities, is the most challenging one. It calls for sophisticated image processing and image analysis techniques, and frequently ad hoc methods have to be developed to identify specific features in the weld image. The difficulty of this task is generally not due to limited computing power. In most cases it was found that a modest personal computer or workstation could carry out most computations in a reasonably short time period. Rather, the algorithms and methods necessary for identifying weld discontinuities were in some cases limited. The fact that specific techniques were finally developed and

  13. 46 CFR 164.120-11 - Production quality control requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 6 2014-10-01 2014-10-01 false Production quality control requirements. 164.120-11... Rescue Boats § 164.120-11 Production quality control requirements. The resin manufacturer must institute a quality control procedure to ensure that all Coast Guard-accepted resin is produced to the same...

  14. 46 CFR 164.120-11 - Production quality control requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 6 2012-10-01 2012-10-01 false Production quality control requirements. 164.120-11... Rescue Boats § 164.120-11 Production quality control requirements. The resin manufacturer must institute a quality control procedure to ensure that all Coast Guard-accepted resin is produced to the same...

  15. 46 CFR 164.120-11 - Production quality control requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 6 2013-10-01 2013-10-01 false Production quality control requirements. 164.120-11... Rescue Boats § 164.120-11 Production quality control requirements. The resin manufacturer must institute a quality control procedure to ensure that all Coast Guard-accepted resin is produced to the same...

  16. Application of clinical assay quality control (QC) to multivariate proteomics data: a workflow exemplified by 2-DE QC.

    PubMed

    Jackson, David; Bramwell, David

    2013-12-16

    only for reasons of scope, but the principles applied are also important for ongoing QC, and this work serves as a step towards a later demonstration of that application. This article is part of a Special Issue entitled: Standardization and Quality Control in Proteomics. © 2013.

  17. Quality Control Technician Curriculum. An Elusive Butterfly.

    ERIC Educational Resources Information Center

    Holler, Michael

    Defining and developing a quality control technician curriculum for an associate degree program is a difficult and puzzling job. There are as many definitions of quality control and curriculum ideas as there are educators asked. However, one could start by dividing the field into its major areas--heavy manufacturing, maintenance, research, and…

  18. Helicopter mathematical models and control law development for handling qualities research

    NASA Technical Reports Server (NTRS)

    Chen, Robert T. N.; Lebacqz, J. Victor; Aiken, Edwin W.; Tischler, Mark B.

    1988-01-01

    Progress made in joint NASA/Army research concerning rotorcraft flight-dynamics modeling, design methodologies for rotorcraft flight-control laws, and rotorcraft parameter identification is reviewed. Research into these interactive disciplines is needed to develop the analytical tools necessary to conduct flying qualities investigations using both the ground-based and in-flight simulators, and to permit an efficient means of performing flight test evaluation of rotorcraft flying qualities for specification compliance. The need for the research is particularly acute for rotorcraft because of their mathematical complexity, high order dynamic characteristics, and demanding mission requirements. The research in rotorcraft flight-dynamics modeling is pursued along two general directions: generic nonlinear models and nonlinear models for specific rotorcraft. In addition, linear models are generated that extend their utilization from 1-g flight to high-g maneuvers and expand their frequency range of validity for the design analysis of high-gain flight control systems. A variety of methods ranging from classical frequency-domain approaches to modern time-domain control methodology that are used in the design of rotorcraft flight control laws is reviewed. Also reviewed is a study conducted to investigate the design details associated with high-gain, digital flight control systems for combat rotorcraft. Parameter identification techniques developed for rotorcraft applications are reviewed.

  19. A multiple objective optimization approach to quality control

    NASA Technical Reports Server (NTRS)

    Seaman, Christopher Michael

    1991-01-01

    The use of product quality as the performance criteria for manufacturing system control is explored. The goal in manufacturing, for economic reasons, is to optimize product quality. The problem is that since quality is a rather nebulous product characteristic, there is seldom an analytic function that can be used as a measure. Therefore standard control approaches, such as optimal control, cannot readily be applied. A second problem with optimizing product quality is that it is typically measured along many dimensions: there are many apsects of quality which must be optimized simultaneously. Very often these different aspects are incommensurate and competing. The concept of optimality must now include accepting tradeoffs among the different quality characteristics. These problems are addressed using multiple objective optimization. It is shown that the quality control problem can be defined as a multiple objective optimization problem. A controller structure is defined using this as the basis. Then, an algorithm is presented which can be used by an operator to interactively find the best operating point. Essentially, the algorithm uses process data to provide the operator with two pieces of information: (1) if it is possible to simultaneously improve all quality criteria, then determine what changes to the process input or controller parameters should be made to do this; and (2) if it is not possible to improve all criteria, and the current operating point is not a desirable one, select a criteria in which a tradeoff should be made, and make input changes to improve all other criteria. The process is not operating at an optimal point in any sense if no tradeoff has to be made to move to a new operating point. This algorithm ensures that operating points are optimal in some sense and provides the operator with information about tradeoffs when seeking the best operating point. The multiobjective algorithm was implemented in two different injection molding scenarios

  20. Application of Total Quality Management in Education

    ERIC Educational Resources Information Center

    Farooq, M. S.; Akhtar, M. S.; Ullah, S. Zia; Memon, R. A.

    2007-01-01

    The purpose of the paper is to analyzing thoughts of the modern management paradigm "Total Quality Management" (TQM), and its application in the field of education. The basic theme of TQM is participatory approach to address the question(s) of quality in business aswell as in the field of education. Reviewing fresh literature from the internet …

  1. 7 CFR 58.523 - Laboratory and quality control tests.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  2. 7 CFR 58.523 - Laboratory and quality control tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  3. 7 CFR 58.523 - Laboratory and quality control tests.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  4. 7 CFR 58.523 - Laboratory and quality control tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  5. 7 CFR 58.523 - Laboratory and quality control tests.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 3 2012-01-01 2012-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  6. 21 CFR 640.56 - Quality control test for potency.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... quality control test for potency may be performed by a clinical laboratory which meets the standards of... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Quality control test for potency. 640.56 Section...) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Cryoprecipitate § 640.56 Quality control...

  7. Web quality control for lectures: Supercourse and Amazon.com.

    PubMed

    Linkov, Faina; LaPorte, Ronald; Lovalekar, Mita; Dodani, Sunita

    2005-12-01

    Peer review has been at the corner stone of quality control of the biomedical journals in the past 300 years. With the emergency of the Internet, new models of quality control and peer review are emerging. However, such models are poorly investigated. We would argue that the popular system of quality control used in Amazon.com offers a way to ensure continuous quality improvement in the area of research communications on the Internet. Such system is providing an interesting alternative to the traditional peer review approaches used in the biomedical journals and challenges the traditional paradigms of scientific publishing. This idea is being explored in the context of Supercourse, a library of 2,350 prevention lectures, shared for free by faculty members from over 150 countries. Supercourse is successfully utilizing quality control approaches that are similar to Amazon.com model. Clearly, the existing approaches and emerging alternatives for quality control in scientific communications needs to be assessed scientifically. Rapid explosion of internet technologies could be leveraged to produce better, more cost effective systems for quality control in the biomedical publications and across all sciences.

  8. 40 CFR 81.107 - Greenwood Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Regions § 81.107 Greenwood Intrastate Air Quality Control Region. The Greenwood Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Greenwood Intrastate Air Quality...

  9. 40 CFR 81.108 - Columbia Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Regions § 81.108 Columbia Intrastate Air Quality Control Region. The Columbia Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... 40 Protection of Environment 17 2011-07-01 2011-07-01 false Columbia Intrastate Air Quality...

  10. 40 CFR 81.108 - Columbia Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Regions § 81.108 Columbia Intrastate Air Quality Control Region. The Columbia Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Columbia Intrastate Air Quality...

  11. 40 CFR 81.111 - Georgetown Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Regions § 81.111 Georgetown Intrastate Air Quality Control Region. The Georgetown Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... 40 Protection of Environment 17 2011-07-01 2011-07-01 false Georgetown Intrastate Air Quality...

  12. 40 CFR 81.109 - Florence Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Regions § 81.109 Florence Intrastate Air Quality Control Region. The Florence Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Florence Intrastate Air Quality...

  13. 40 CFR 81.111 - Georgetown Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Regions § 81.111 Georgetown Intrastate Air Quality Control Region. The Georgetown Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Georgetown Intrastate Air Quality...

  14. 40 CFR 81.109 - Florence Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Regions § 81.109 Florence Intrastate Air Quality Control Region. The Florence Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... 40 Protection of Environment 17 2011-07-01 2011-07-01 false Florence Intrastate Air Quality...

  15. 40 CFR 81.107 - Greenwood Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Regions § 81.107 Greenwood Intrastate Air Quality Control Region. The Greenwood Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... 40 Protection of Environment 17 2011-07-01 2011-07-01 false Greenwood Intrastate Air Quality...

  16. Contractor Performed Quality Control on KyTC Projects.

    DOT National Transportation Integrated Search

    2002-08-01

    This report addresses issues related to transferring the responsibility for quality control from the Kentucky Transportation Cabinet (KyTC) to construction contractors. : Several key topics related to Contractor Performed Quality Control (CPQC) are p...

  17. Application of the suggestion system in the improvement of the production process and product quality control

    NASA Astrophysics Data System (ADS)

    Gołaś, H.; Mazur, A.; Gruszka, J.; Szafer, P.

    2016-08-01

    The elaboration is a case study and the research was carried out in the company Alco-Mot Ltd., which employs 120 people. The company specializes in the production of lead poles for industrial and traction batteries using gravity casting. The elements embedded in the cast are manufactured on a machining centre, which provides the stability of the process and of the dimensions of the product as well as a very short production time. As a result of observation and analysis the authors have developed a concept for the implementation of a dynamic suggestion system in ALCO-MOT, including, among others, a standard for actions in the implementation of the suggestion system, as well as clear guidelines for the processing and presentation of the activities undertaken in the time between the establishment of the concept (suggestions) and the benefits analysis after the proposed solutions have been implemented. The authors also present how suggestions proposed by ALCO-MOT staff contributed to the improvement of the processes of production and quality control. Employees offered more than 30 suggestions, of which more than a half are being implemented now and further actions are being prepared for implementation. The authors will present the results of improvements in, for example, tool replacement time, scrap reduction. The authors will present how kaizen can improve the production and quality control processes. They will present how the production and quality control processes looked before and after the implementation of employee suggestions.

  18. [Pharmaceutical product quality control and good manufacturing practices].

    PubMed

    Hiyama, Yukio

    2010-01-01

    This report describes the roles of Good Manufacturing Practices (GMP) in pharmaceutical product quality control. There are three keys to pharmaceutical product quality control. They are specifications, thorough product characterization during development, and adherence to GMP as the ICH Q6A guideline on specifications provides the most important principles in its background section. Impacts of the revised Pharmaceutical Affairs Law (rPAL) which became effective in 2005 on product quality control are discussed. Progress of ICH discussion for Pharmaceutical Development (Q8), Quality Risk Management (Q9) and Pharmaceutical Quality System (Q10) are reviewed. In order to reconstruct GMP guidelines and GMP inspection system in the regulatory agencies under the new paradigm by rPAL and the ICH, a series of Health Science studies were conducted. For GMP guidelines, product GMP guideline, technology transfer guideline, laboratory control guideline and change control system guideline were written. For the GMP inspection system, inspection check list, inspection memo and inspection scenario were proposed also by the Health Science study groups. Because pharmaceutical products and their raw materials are manufactured and distributed internationally, collaborations with other national authorities are highly desired. In order to enhance the international collaborations, consistent establishment of GMP inspection quality system throughout Japan will be essential.

  19. 21 CFR 862.1660 - Quality control material (assayed and unassayed).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Quality control material (assayed and unassayed... Test Systems § 862.1660 Quality control material (assayed and unassayed). (a) Identification. A quality... that may arise from reagent or analytical instrument variation. A quality control material (assayed and...

  20. Crowdsourcing quality control for Dark Energy Survey images

    DOE PAGES

    Melchior, P.

    2016-07-01

    We have developed a crowdsourcing web application for image quality control employed by the Dark Energy Survey. Dubbed the "DES exposure checker", it renders science-grade images directly to a web browser and allows users to mark problematic features from a set of predefined classes. Users can also generate custom labels and thus help identify previously unknown problem classes. User reports are fed back to hardware and software experts to help mitigate and eliminate recognized issues. We report on the implementation of the application and our experience with its over 100 users, the majority of which are professional or prospective astronomersmore » but not data management experts. We discuss aspects of user training and engagement, and demonstrate how problem reports have been pivotal to rapidly correct artifacts which would likely have been too subtle or infrequent to be recognized otherwise. We conclude with a number of important lessons learned, suggest possible improvements, and recommend this collective exploratory approach for future astronomical surveys or other extensive data sets with a sufficiently large user base. We also release open-source code of the web application and host an online demo versionat http://des-exp-checker.pmelchior.net« less

  1. Crowdsourcing quality control for Dark Energy Survey images

    NASA Astrophysics Data System (ADS)

    Melchior, P.; Sheldon, E.; Drlica-Wagner, A.; Rykoff, E. S.; Abbott, T. M. C.; Abdalla, F. B.; Allam, S.; Benoit-Lévy, A.; Brooks, D.; Buckley-Geer, E.; Carnero Rosell, A.; Carrasco Kind, M.; Carretero, J.; Crocce, M.; D'Andrea, C. B.; da Costa, L. N.; Desai, S.; Doel, P.; Evrard, A. E.; Finley, D. A.; Flaugher, B.; Frieman, J.; Gaztanaga, E.; Gerdes, D. W.; Gruen, D.; Gruendl, R. A.; Honscheid, K.; James, D. J.; Jarvis, M.; Kuehn, K.; Li, T. S.; Maia, M. A. G.; March, M.; Marshall, J. L.; Nord, B.; Ogando, R.; Plazas, A. A.; Romer, A. K.; Sanchez, E.; Scarpine, V.; Sevilla-Noarbe, I.; Smith, R. C.; Soares-Santos, M.; Suchyta, E.; Swanson, M. E. C.; Tarle, G.; Vikram, V.; Walker, A. R.; Wester, W.; Zhang, Y.

    2016-07-01

    We have developed a crowdsourcing web application for image quality control employed by the Dark Energy Survey. Dubbed the "DES exposure checker", it renders science-grade images directly to a web browser and allows users to mark problematic features from a set of predefined classes. Users can also generate custom labels and thus help identify previously unknown problem classes. User reports are fed back to hardware and software experts to help mitigate and eliminate recognized issues. We report on the implementation of the application and our experience with its over 100 users, the majority of which are professional or prospective astronomers but not data management experts. We discuss aspects of user training and engagement, and demonstrate how problem reports have been pivotal to rapidly correct artifacts which would likely have been too subtle or infrequent to be recognized otherwise. We conclude with a number of important lessons learned, suggest possible improvements, and recommend this collective exploratory approach for future astronomical surveys or other extensive data sets with a sufficiently large user base. We also release open-source code of the web application and host an online demo version at http://des-exp-checker.pmelchior.net.

  2. Crowdsourcing quality control for Dark Energy Survey images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Melchior, P.

    We have developed a crowdsourcing web application for image quality control employed by the Dark Energy Survey. Dubbed the "DES exposure checker", it renders science-grade images directly to a web browser and allows users to mark problematic features from a set of predefined classes. Users can also generate custom labels and thus help identify previously unknown problem classes. User reports are fed back to hardware and software experts to help mitigate and eliminate recognized issues. We report on the implementation of the application and our experience with its over 100 users, the majority of which are professional or prospective astronomersmore » but not data management experts. We discuss aspects of user training and engagement, and demonstrate how problem reports have been pivotal to rapidly correct artifacts which would likely have been too subtle or infrequent to be recognized otherwise. We conclude with a number of important lessons learned, suggest possible improvements, and recommend this collective exploratory approach for future astronomical surveys or other extensive data sets with a sufficiently large user base. We also release open-source code of the web application and host an online demo versionat http://des-exp-checker.pmelchior.net« less

  3. QUALITY ASSURANCE AND QUALITY CONTROL FOR WASTE CONTAINMENT FACILITIES. Project Summary

    EPA Science Inventory

    It is generally agreed that both quality assurance (QA) and quality control (QC) are essential to the proper installation and eventual performance of environmentally safe and secure waste containment systems. Even further, there are both manufacturing and construction aspects to...

  4. Vehicle design considerations for active control application to subsonic transport aircraft

    NASA Technical Reports Server (NTRS)

    Hofmann, L. G.; Clement, W. F.

    1974-01-01

    The state of the art in active control technology is summarized. How current design criteria and airworthiness regulations might restrict application of this emerging technology to subsonic CTOL transports of the 1980's are discussed. Facets of active control technology considered are: (1) augmentation of relaxed inherent stability; (2) center-of-gravity control; (3) ride quality control; (4) load control; (5) flutter control; (6) envelope limiting, and (7) pilot interface with the control system. A summary and appraisal of the current state of the art, design criteria, and recommended practices, as well as a projection of the risk in applying each of these facets of active control technology is given. A summary of pertinent literature and technical expansions is included.

  5. Multi-Agent Architecture with Support to Quality of Service and Quality of Control

    NASA Astrophysics Data System (ADS)

    Poza-Luján, Jose-Luis; Posadas-Yagüe, Juan-Luis; Simó-Ten, Jose-Enrique

    Multi Agent Systems (MAS) are one of the most suitable frameworks for the implementation of intelligent distributed control system. Agents provide suitable flexibility to give support to implied heterogeneity in cyber-physical systems. Quality of Service (QoS) and Quality of Control (QoC) parameters are commonly utilized to evaluate the efficiency of the communications and the control loop. Agents can use the quality measures to take a wide range of decisions, like suitable placement on the control node or to change the workload to save energy. This article describes the architecture of a multi agent system that provides support to QoS and QoC parameters to optimize de system. The architecture uses a Publish-Subscriber model, based on Data Distribution Service (DDS) to send the control messages. Due to the nature of the Publish-Subscribe model, the architecture is suitable to implement event-based control (EBC) systems. The architecture has been called FSACtrl.

  6. 40 CFR 81.87 - Metropolitan Boise Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.87 Section 81.87 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.87 Metropolitan Boise Intrastate Air Quality Control Region. The Metropolitan Boise Intrastate Air Quality Control Region (Idaho) consists of the territorial area encompassed...

  7. 40 CFR 81.89 - Metropolitan Cheyenne Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.89 Section 81.89 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.89 Metropolitan Cheyenne Intrastate Air Quality Control Region. The Metropolitan Cheyenne Intrastate Air Quality Control Region (Wyoming) consists of the territorial area...

  8. 40 CFR 81.101 - Metropolitan Dubuque Interstate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.101 Section 81.101 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.101 Metropolitan Dubuque Interstate Air Quality Control Region. The Metropolitan Dubuque Interstate Air Quality Control Region (Illinois-Iowa-Wisconsin) consists of the...

  9. 40 CFR 81.104 - Central Pennsylvania Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.104 Section 81.104 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.104 Central Pennsylvania Intrastate Air Quality Control Region. The Central Pennsylvania Intrastate Air Quality Control Region consists of the territorial area encompassed by...

  10. 40 CFR 81.106 - Greenville-Spartanburg Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.106 Section 81.106 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.106 Greenville-Spartanburg Intrastate Air Quality Control Region. The Greenville-Spartanburg Intrastate Air Quality Control Region (South Carolina) consists of the territorial...

  11. 40 CFR 81.120 - Middle Tennessee Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.120 Section 81.120 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.120 Middle Tennessee Intrastate Air Quality Control Region. The Middle Tennessee Intrastate Air Quality Control Region consists of the territorial area encompassed by...

  12. 40 CFR 81.75 - Metropolitan Charlotte Interstate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.75 Section 81.75 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.75 Metropolitan Charlotte Interstate Air Quality Control Region. The Metropolitan Charlotte Interstate Air Quality Control Region (North Carolina-South Carolina) has been revised...

  13. 40 CFR 81.79 - Northeastern Oklahoma Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.79 Section 81.79 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.79 Northeastern Oklahoma Intrastate Air Quality Control Region. The Metropolitan Tulsa Intrastate Air Quality Control Region has been renamed the Northeastern Oklahoma Intrastate...

  14. 40 CFR 81.119 - Western Tennessee Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.119 Section 81.119 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.119 Western Tennessee Intrastate Air Quality Control Region. The Western Tennessee Intrastate Air Quality Control Region consists of the territorial area encompassed by...

  15. 40 CFR 81.104 - Central Pennsylvania Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.104 Section 81.104 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.104 Central Pennsylvania Intrastate Air Quality Control Region. The Central Pennsylvania Intrastate Air Quality Control Region consists of the territorial area encompassed by...

  16. 40 CFR 81.87 - Metropolitan Boise Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.87 Section 81.87 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.87 Metropolitan Boise Intrastate Air Quality Control Region. The Metropolitan Boise Intrastate Air Quality Control Region (Idaho) consists of the territorial area encompassed...

  17. 40 CFR 81.79 - Northeastern Oklahoma Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.79 Section 81.79 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.79 Northeastern Oklahoma Intrastate Air Quality Control Region. The Metropolitan Tulsa Intrastate Air Quality Control Region has been renamed the Northeastern Oklahoma Intrastate...

  18. 40 CFR 81.101 - Metropolitan Dubuque Interstate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.101 Section 81.101 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.101 Metropolitan Dubuque Interstate Air Quality Control Region. The Metropolitan Dubuque Interstate Air Quality Control Region (Illinois-Iowa-Wisconsin) consists of the...

  19. 40 CFR 81.106 - Greenville-Spartanburg Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.106 Section 81.106 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.106 Greenville-Spartanburg Intrastate Air Quality Control Region. The Greenville-Spartanburg Intrastate Air Quality Control Region (South Carolina) consists of the territorial...

  20. 40 CFR 81.89 - Metropolitan Cheyenne Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.89 Section 81.89 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.89 Metropolitan Cheyenne Intrastate Air Quality Control Region. The Metropolitan Cheyenne Intrastate Air Quality Control Region (Wyoming) consists of the territorial area...

  1. 40 CFR 81.62 - Northeast Mississippi Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.62 Section 81.62 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.62 Northeast Mississippi Intrastate Air Quality Control Region. The Alabama-Mississippi-Tennessee Interstate Air Quality Control Region has been renamed the Northeast...

  2. 40 CFR 81.78 - Metropolitan Portland Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.78 Section 81.78 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.78 Metropolitan Portland Intrastate Air Quality Control Region. The Metropolitan Portland Intrastate Air Quality Control Region (Maine) consists of the territorial area...

  3. Quality assessment concept of the World Data Center for Climate and its application to CMIP5 data

    NASA Astrophysics Data System (ADS)

    Stockhause, M.; Höck, H.; Toussaint, F.; Lautenschlager, M.

    2012-08-01

    The preservation of data in a high state of quality which is suitable for interdisciplinary use is one of the most pressing and challenging current issues in long-term archiving. For high volume data such as climate model data, the data and data replica are no longer stored centrally but distributed over several local data repositories, e.g. the data of the Climate Model Intercomparison Project Phase 5 (CMIP5). The most important part of the data is to be archived, assigned a DOI, and published according to the World Data Center for Climate's (WDCC) application of the DataCite regulations. The integrated part of WDCC's data publication process, the data quality assessment, was adapted to the requirements of a federated data infrastructure. A concept of a distributed and federated quality assessment procedure was developed, in which the workload and responsibility for quality control is shared between the three primary CMIP5 data centers: Program for Climate Model Diagnosis and Intercomparison (PCMDI), British Atmospheric Data Centre (BADC), and WDCC. This distributed quality control concept, its pilot implementation for CMIP5, and first experiences are presented. The distributed quality control approach is capable of identifying data inconsistencies and to make quality results immediately available for data creators, data users and data infrastructure managers. Continuous publication of new data versions and slow data replication prevents the quality control from check completion. This together with ongoing developments of the data and metadata infrastructure requires adaptations in code and concept of the distributed quality control approach.

  4. Intelligent Control Approaches for Aircraft Applications

    NASA Technical Reports Server (NTRS)

    Gundy-Burlet, Karen; KrishnaKumar, K.; Soloway, Don; Kaneshige, John; Clancy, Daniel (Technical Monitor)

    2001-01-01

    This paper presents an overview of various intelligent control technologies currently being developed and studied under the Intelligent Flight Control (IFC) program at the NASA Ames Research Center. The main objective of the intelligent flight control program is to develop the next generation of flight controllers for the purpose of automatically compensating for a broad spectrum of damaged or malfunctioning aircraft components and to reduce control law development cost and time. The approaches being examined include: (a) direct adaptive dynamic inverse controller and (b) an adaptive critic-based dynamic inverse controller. These approaches can utilize, but do not require, fault detection and isolation information. Piloted simulation studies are performed to examine if the intelligent flight control techniques adequately: 1) Match flying qualities of modern fly-by-wire flight controllers under nominal conditions; 2) Improve performance under failure conditions when sufficient control authority is available; and 3) Achieve consistent handling qualities across the flight envelope and for different aircraft configurations. Results obtained so far demonstrate the potential for improving handling qualities and significantly increasing survivability rates under various simulated failure conditions.

  5. Consensus definitions and application guidelines for control groups in cerebrospinal fluid biomarker studies in multiple sclerosis.

    PubMed

    Teunissen, Charlotte; Menge, Til; Altintas, Ayse; Álvarez-Cermeño, José C; Bertolotto, Antonio; Berven, Frode S; Brundin, Lou; Comabella, Manuel; Degn, Matilde; Deisenhammer, Florian; Fazekas, Franz; Franciotta, Diego; Frederiksen, Jette L; Galimberti, Daniela; Gnanapavan, Sharmilee; Hegen, Harald; Hemmer, Bernhard; Hintzen, Rogier; Hughes, Steve; Iacobaeus, Ellen; Kroksveen, Ann C; Kuhle, Jens; Richert, John; Tumani, Hayrettin; Villar, Luisa M; Drulovic, Jelena; Dujmovic, Irena; Khalil, Michael; Bartos, Ales

    2013-11-01

    The choice of appropriate control group(s) is critical in cerebrospinal fluid (CSF) biomarker research in multiple sclerosis (MS). There is a lack of definitions and nomenclature of different control groups and a rationalized application of different control groups. We here propose consensus definitions and nomenclature for the following groups: healthy controls (HCs), spinal anesthesia subjects (SASs), inflammatory neurological disease controls (INDCs), peripheral inflammatory neurological disease controls (PINDCs), non-inflammatory neurological controls (NINDCs), symptomatic controls (SCs). Furthermore, we discuss the application of these control groups in specific study designs, such as for diagnostic biomarker studies, prognostic biomarker studies and therapeutic response studies. Application of these uniform definitions will lead to better comparability of biomarker studies and optimal use of available resources. This will lead to improved quality of CSF biomarker research in MS and related disorders.

  6. 40 CFR 81.77 - Puerto Rico Air Quality Control Region.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 18 2014-07-01 2014-07-01 false Puerto Rico Air Quality Control Region... Control Regions § 81.77 Puerto Rico Air Quality Control Region. The Puerto Rico Air Quality Control Region... delimited): The entire Commonwealth of Puerto Rico: Puerto Rico and surrounding islands, Vieques and...

  7. HPLC for quality control of polyimides

    NASA Technical Reports Server (NTRS)

    Young, P. R.; Sykes, G. F.

    1979-01-01

    High Pressure Liquid Chromatography (HPLC) as a quality control tool for polyimide resins and prepregs are presented. A data base to help establish accept/reject criteria for these materials was developed. This work is intended to supplement, not replace, standard quality control tests normally conducted on incoming resins and prepregs. To help achieve these objectives, the HPLC separation of LARC-160 polyimide precursor resin was characterized. Room temperature resin aging effects were studied. Graphite reinforced composites made from fresh and aged resin were fabricated and tested to determine if changes observed by HPLC were significant.

  8. COMMUNITY MULTISCALE AIR QUALITY ( CMAQ ) MODEL - QUALITY ASSURANCE AND VERSION CONTROL

    EPA Science Inventory

    This presentation will be given to the EPA Exposure Modeling Workgroup on January 24, 2006. The quality assurance and version control procedures for the Community Multiscale Air Quality (CMAQ) Model are presented. A brief background of CMAQ is given, then issues related to qual...

  9. Nuclear Technology Series. Course 14: Introduction to Quality Assurance/Quality Control.

    ERIC Educational Resources Information Center

    Technical Education Research Center, Waco, TX.

    This technical specialty course is one of thirty-five courses designed for use by two-year postsecondary institutions in five nuclear technician curriculum areas: (1) radiation protection technician, (2) nuclear instrumentation and control technician, (3) nuclear materials processing technician, (4) nuclear quality-assurance/quality-control…

  10. Implementing self sustained quality control procedures in a clinical laboratory.

    PubMed

    Khatri, Roshan; K C, Sanjay; Shrestha, Prabodh; Sinha, J N

    2013-01-01

    Quality control is an essential component in every clinical laboratory which maintains the excellence of laboratory standards, supplementing to proper disease diagnosis, patient care and resulting in overall strengthening of health care system. Numerous quality control schemes are available, with combinations of procedures, most of which are tedious, time consuming and can be "too technical" whereas commercially available quality control materials can be expensive especially for laboratories in developing nations like Nepal. Here, we present a procedure performed at our centre with self prepared control serum and use of simple statistical tools for quality assurance. The pooled serum was prepared as per guidelines for preparation of stabilized liquid quality control serum from human sera. Internal Quality Assessment was performed on this sample, on a daily basis which included measurement of 12 routine biochemical parameters. The results were plotted on Levey-Jennings charts and analysed with quality control rules, for a period of one month. The mean levels of biochemical analytes in self prepared control serum were within normal physiological range. This serum was evaluated every day along with patients' samples. The results obtained were plotted on control charts and analysed using common quality control rules to identify possible systematic and random errors. Immediate mitigation measures were taken and the dispatch of erroneous reports was avoided. In this study we try to highlight on a simple internal quality control procedure which can be performed by laboratories, with minimum technology, expenditure, and expertise and improve reliability and validity of the test reports.

  11. 40 CFR 81.118 - Southwest Missouri Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.118 Section 81.118 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.118 Southwest Missouri Intrastate Air Quality Control Region. The Southwest Missouri Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  12. 40 CFR 81.116 - Northern Missouri Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.116 Section 81.116 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.116 Northern Missouri Intrastate Air Quality Control Region. The Northern Missouri Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  13. 40 CFR 81.97 - Southwest Florida Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.97 Section 81.97 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.97 Southwest Florida Intrastate Air Quality Control Region. The Southwest Florida Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  14. 40 CFR 81.117 - Southeast Missouri Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.117 Section 81.117 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.117 Southeast Missouri Intrastate Air Quality Control Region. The Southeast Missouri Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  15. 40 CFR 81.98 - Burlington-Keokuk Interstate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.98 Section 81.98 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.98 Burlington-Keokuk Interstate Air Quality Control Region. The Burlington-Keokuk Interstate Air Quality Control Region (Illinois-Iowa) is revised to consist of the...

  16. 40 CFR 81.118 - Southwest Missouri Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.118 Section 81.118 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.118 Southwest Missouri Intrastate Air Quality Control Region. The Southwest Missouri Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  17. 40 CFR 81.115 - Northwest Nevada Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.115 Section 81.115 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.115 Northwest Nevada Intrastate Air Quality Control Region. The Northwest Nevada Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  18. 40 CFR 81.116 - Northern Missouri Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.116 Section 81.116 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.116 Northern Missouri Intrastate Air Quality Control Region. The Northern Missouri Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  19. 40 CFR 81.123 - Southeastern Oklahoma Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.123 Section 81.123 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.123 Southeastern Oklahoma Intrastate Air Quality Control Region. The Southeastern Oklahoma Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  20. 40 CFR 81.67 - Lake Michigan Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Regions § 81.67 Lake Michigan Intrastate Air Quality Control Region. The Menominee-Escanaba (Michigan)-Marinette (Wisconsin) Interstate Air Quality Control Region has been renamed the Lake Michigan Intrastate Air Quality Control Region (Wisconsin) and revised to consist of the territorial area...

  1. 40 CFR 81.115 - Northwest Nevada Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.115 Section 81.115 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.115 Northwest Nevada Intrastate Air Quality Control Region. The Northwest Nevada Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  2. 40 CFR 81.97 - Southwest Florida Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.97 Section 81.97 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.97 Southwest Florida Intrastate Air Quality Control Region. The Southwest Florida Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  3. 40 CFR 81.117 - Southeast Missouri Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.117 Section 81.117 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.117 Southeast Missouri Intrastate Air Quality Control Region. The Southeast Missouri Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  4. 40 CFR 81.122 - Mississippi Delta Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.122 Section 81.122 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.122 Mississippi Delta Intrastate Air Quality Control Region. The Mississippi Delta Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  5. 40 CFR 81.98 - Burlington-Keokuk Interstate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.98 Section 81.98 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.98 Burlington-Keokuk Interstate Air Quality Control Region. The Burlington-Keokuk Interstate Air Quality Control Region (Illinois-Iowa) is revised to consist of the...

  6. Coping and social problem solving correlates of asthma control and quality of life.

    PubMed

    McCormick, Sean P; Nezu, Christine M; Nezu, Arthur M; Sherman, Michael; Davey, Adam; Collins, Bradley N

    2014-02-01

    In a sample of adults with asthma receiving care and medication in an outpatient pulmonary clinic, this study tested for statistical associations between social problem-solving styles, asthma control, and asthma-related quality of life. These variables were measured cross sectionally as a first step toward more systematic application of social problem-solving frameworks in asthma self-management training. Recruitment occurred during pulmonology clinic service hours. Forty-four adults with physician-confirmed diagnosis of asthma provided data including age, gender, height, weight, race, income, and comorbid conditions. The Asthma Control Questionnaire, the Mini Asthma Quality of Life Questionnaire (Short Form), and peak expiratory force measures offered multiple views of asthma health at the time of the study. Maladaptive coping (impulsive and careless problem-solving styles) based on transactional stress models of health were assessed with the Social Problem-Solving Inventory-Revised: Short Form. Controlling for variance associated with gender, age, and income, individuals reporting higher impulsive-careless scores exhibited significantly lower scores on asthma control (β = 0.70, p = 0.001, confidence interval (CI) [0.37-1.04]) and lower asthma-related quality of life (β = 0.79, p = 0.017, CI [0.15-1.42]). These findings suggest that specific maladaptive problem-solving styles may uniquely contribute to asthma health burdens. Because problem-solving coping strategies are both measureable and teachable, behavioral interventions aimed at facilitating adaptive coping and problem solving could positively affect patient's asthma management and quality of life.

  7. 20 CFR 602.41 - Proper expenditure of Quality Control granted funds.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 20 Employees' Benefits 3 2011-04-01 2011-04-01 false Proper expenditure of Quality Control granted... LABOR QUALITY CONTROL IN THE FEDERAL-STATE UNEMPLOYMENT INSURANCE SYSTEM Quality Control Grants to States § 602.41 Proper expenditure of Quality Control granted funds. The Secretary may, after reasonable...

  8. 20 CFR 602.41 - Proper expenditure of Quality Control granted funds.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Proper expenditure of Quality Control granted... LABOR QUALITY CONTROL IN THE FEDERAL-STATE UNEMPLOYMENT INSURANCE SYSTEM Quality Control Grants to States § 602.41 Proper expenditure of Quality Control granted funds. The Secretary may, after reasonable...

  9. A Model of Risk Analysis in Analytical Methodology for Biopharmaceutical Quality Control.

    PubMed

    Andrade, Cleyton Lage; Herrera, Miguel Angel De La O; Lemes, Elezer Monte Blanco

    2018-01-01

    control laboratory: It is laborious, time consuming, semi-quantitative, and requires a radioisotope. Along with dot-blot hybridization, two alternatives techniques were evaluated: threshold analysis and quantitative polymerase chain reaction. Quality risk management tools were applied to compare the techniques, taking into account the uncertainties, the possibility of circumstances or future events, and their effects upon method performance. By illustrating the application of these tools with DNA methods, we provide an example of how they can be used to support a scientific and practical approach to decision making and can assess and manage method performance risk using such tools. This paper discusses, considering the principles of quality risk management, an additional approach to the development and selection of analytical quality control methods using the risk analysis tool hazard analysis and critical control points. This tool provides the possibility to find the method procedural steps with higher impact on method reliability (called critical control points). Our model concluded that the radioactive dot-blot assay has the larger number of critical control points, followed by quantitative polymerase chain reaction and threshold analysis. Quantitative polymerase chain reaction is shown to be the better alternative analytical methodology in residual cellular DNA analysis. © PDA, Inc. 2018.

  10. Japanese Quality Control Circles.

    ERIC Educational Resources Information Center

    Nishiyama, Kazuo

    In recent years, United States scholars with an interest in international business and organizational communication have begun to notice the success of Japanese "quality control circles." These are small groups, usually composed of seven to ten workers, who are organized at the production levels within most large Japanese factories. A…

  11. 14 CFR 21.143 - Quality control data requirements; prime manufacturer.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Quality control data requirements; prime... describing assigned responsibilities and delegated authority of the quality control organization, together with a chart indicating the functional relationship of the quality control organization to management...

  12. 40 CFR 81.51 - Portland Interstate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Control Region. 81.51 Section 81.51 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.51 Portland Interstate Air Quality Control Region. The Portland Interstate...

  13. 40 CFR 81.51 - Portland Interstate Air Quality Control Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Control Region. 81.51 Section 81.51 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.51 Portland Interstate Air Quality Control Region. The Portland Interstate...

  14. 40 CFR 81.51 - Portland Interstate Air Quality Control Region.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Control Region. 81.51 Section 81.51 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.51 Portland Interstate Air Quality Control Region. The Portland Interstate...

  15. 30 CFR 28.32 - Proposed quality control plans; approval by MSHA.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Proposed quality control plans; approval by...-CIRCUIT PROTECTION FOR TRAILING CABLES IN COAL MINES Quality Control § 28.32 Proposed quality control plans; approval by MSHA. (a) Each proposed quality control plan submitted in accordance with this...

  16. 30 CFR 28.32 - Proposed quality control plans; approval by MSHA.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...-CIRCUIT PROTECTION FOR TRAILING CABLES IN COAL MINES Quality Control § 28.32 Proposed quality control plans; approval by MSHA. (a) Each proposed quality control plan submitted in accordance with this... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Proposed quality control plans; approval by...

  17. 30 CFR 28.32 - Proposed quality control plans; approval by MSHA.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...-CIRCUIT PROTECTION FOR TRAILING CABLES IN COAL MINES Quality Control § 28.32 Proposed quality control plans; approval by MSHA. (a) Each proposed quality control plan submitted in accordance with this... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Proposed quality control plans; approval by...

  18. 30 CFR 28.32 - Proposed quality control plans; approval by MSHA.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...-CIRCUIT PROTECTION FOR TRAILING CABLES IN COAL MINES Quality Control § 28.32 Proposed quality control plans; approval by MSHA. (a) Each proposed quality control plan submitted in accordance with this... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Proposed quality control plans; approval by...

  19. CRN5EXP: Expert system for statistical quality control

    NASA Technical Reports Server (NTRS)

    Hentea, Mariana

    1991-01-01

    The purpose of the Expert System CRN5EXP is to assist in checking the quality of the coils at two very important mills: Hot Rolling and Cold Rolling in a steel plant. The system interprets the statistical quality control charts, diagnoses and predicts the quality of the steel. Measurements of process control variables are recorded in a database and sample statistics such as the mean and the range are computed and plotted on a control chart. The chart is analyzed through patterns using the C Language Integrated Production System (CLIPS) and a forward chaining technique to reach a conclusion about the causes of defects and to take management measures for the improvement of the quality control techniques. The Expert System combines the certainty factors associated with the process control variables to predict the quality of the steel. The paper presents the approach to extract data from the database, the reason to combine certainty factors, the architecture and the use of the Expert System. However, the interpretation of control charts patterns requires the human expert's knowledge and lends to Expert Systems rules.

  20. Data Quality Control of the French Permanent Broadband Network in the RESIF Framework.

    NASA Astrophysics Data System (ADS)

    Grunberg, M.; Lambotte, S.; Engels, F.

    2014-12-01

    In the framework of the RESIF (Réseau Sismologique et géodésique Français) project, a new information system is setting up, allowing the improvement of the management and the distribution of high quality data from the different elements of RESIF. Within this information system, EOST (in Strasbourg) is in charge of collecting real-time permanent broadband seismic waveform, and performing Quality Control on these data. The real-time and validated data set are pushed to the French National Distribution Center (Isterre/Grenoble) to make them publicly available. Furthermore EOST hosts the BCSF-ReNaSS, in charge of the French metropolitan seismic bulletin. This allows to benefit from some high-end quality control based on the national and world-wide seismicity. Here we present the real-time seismic data flow from the stations of the French National Broad Band Network to EOST, and then, the data Quality Control procedures that were recently installed, including some new developments.The data Quality Control consists in applying a variety of processes to check the consistency of the whole system from the stations to the data center. This allows us to verify that instruments and data transmission are operating correctly. Moreover, time quality is critical for most of the scientific data applications. To face this challenge and check the consistency of polarities and amplitudes, we deployed several high-end processes including a noise correlation procedure to check for timing accuracy (intrumental time errors result in a time-shift of the whole cross-correlation, clearly distinct from those due to change in medium physical properties), and a systematic comparison of synthetic and real data for teleseismic earthquakes of magnitude larger than 6.5 to detect timing errors as well as polarity and amplitude problems.

  1. 22 CFR 96.39 - Information disclosure and quality control practices.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 22 Foreign Relations 1 2011-04-01 2011-04-01 false Information disclosure and quality control... for Convention Accreditation and Approval Information Disclosure, Fee Practices, and Quality Control Policies and Practices § 96.39 Information disclosure and quality control practices. (a) The agency or...

  2. 22 CFR 96.39 - Information disclosure and quality control practices.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Information disclosure and quality control... for Convention Accreditation and Approval Information Disclosure, Fee Practices, and Quality Control Policies and Practices § 96.39 Information disclosure and quality control practices. (a) The agency or...

  3. 22 CFR 96.39 - Information disclosure and quality control practices.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 22 Foreign Relations 1 2014-04-01 2014-04-01 false Information disclosure and quality control... for Convention Accreditation and Approval Information Disclosure, Fee Practices, and Quality Control Policies and Practices § 96.39 Information disclosure and quality control practices. (a) The agency or...

  4. 22 CFR 96.39 - Information disclosure and quality control practices.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 22 Foreign Relations 1 2012-04-01 2012-04-01 false Information disclosure and quality control... for Convention Accreditation and Approval Information Disclosure, Fee Practices, and Quality Control Policies and Practices § 96.39 Information disclosure and quality control practices. (a) The agency or...

  5. 22 CFR 96.39 - Information disclosure and quality control practices.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 22 Foreign Relations 1 2013-04-01 2013-04-01 false Information disclosure and quality control... for Convention Accreditation and Approval Information Disclosure, Fee Practices, and Quality Control Policies and Practices § 96.39 Information disclosure and quality control practices. (a) The agency or...

  6. A special ionisation chamber for quality control of diagnostic and mammography X ray equipment.

    PubMed

    Costa, A M; Caldas, L V E

    2003-01-01

    A quality control program for X ray equipment used for conventional radiography and mammography requires the constancy check of the beam qualities in terms of the half-value layers. In this work, a special double-faced parallel-plate ionisation chamber was developed with inner electrodes of different materials, in a tandem system. Its application will be in quality control programs of diagnostic and mammography X ray equipment for confirmation of half-value layers previously determined by the conventional method. Moreover, the chamber also may be utilised for measurements of air kerma values (and air kerma rates) in X radiation fields used for conventional radiography and mammography. The chamber was studied in relation to the characteristics of saturation, ion collection efficiency, polarity effects, leakage current, and short-term stability. The energy dependence in response of each of the two faces of the chamber was determined over the conventional radiography and mammography X ray ranges (unattenuated beams). The different energy response of the two faces of the chamber allowed the formation of a tandem system useful for the constancy check of beam qualities.

  7. Quality control and quality assurance of hot mix asphalt construction in Delaware.

    DOT National Transportation Integrated Search

    2006-07-01

    Since the mid 60s the Federal Highway Administration began to encourage : Departments of Transportation and Contractors toward the use of quality control and : quality assurance (QA/QC) specifications, which are statistically based. : For example,...

  8. Ocean Data Quality Control

    DTIC Science & Technology

    2011-11-18

    the aero- sol at the coincident time and location of the satellite SST retrievals. This informa- tion is available in the daytime for the anti-solar...are of the same form, such as probabilities or standard normal deviates. A quality control decision-making algorithm in use at the U.S. Navy oceano

  9. Discussion of the quality control and performance testing of ultrasound diagnostic equipment

    NASA Astrophysics Data System (ADS)

    Jiang, Junjie

    2018-03-01

    In recent years, with the rapid development of ultrasonography, the application and popularization of new technology used in ultrasound equipment, the level of providing diagnostic information for doctors enhances unceasingly, which has become the indispensable diagnostic tool for medical institutions. The performance of equipment is directly related to the doctor’s diagnosis and the patient’s health, therefore, it is very important to choose a good method for quality control and performance testing.

  10. Statistical survey of XB-70 airplane responses and control usage with an illustration of the application to handling qualities criteria

    NASA Technical Reports Server (NTRS)

    Powers, B. G.

    1972-01-01

    The magnitude and frequency of occurrence of aircraft responses and control inputs during 27 flights of the XB-70 airplane were measured. Exceedance curves are presented for the airplane responses and control usage. A technique is presented which makes use of these exceedance curves to establish or verify handling qualities criteria. This technique can provide a means of incorporating current operational experience in handling qualities requirements for future aircraft.

  11. Quality Controlling CMIP datasets at GFDL

    NASA Astrophysics Data System (ADS)

    Horowitz, L. W.; Radhakrishnan, A.; Balaji, V.; Adcroft, A.; Krasting, J. P.; Nikonov, S.; Mason, E. E.; Schweitzer, R.; Nadeau, D.

    2017-12-01

    As GFDL makes the switch from model development to production in light of the Climate Model Intercomparison Project (CMIP), GFDL's efforts are shifted to testing and more importantly establishing guidelines and protocols for Quality Controlling and semi-automated data publishing. Every CMIP cycle introduces key challenges and the upcoming CMIP6 is no exception. The new CMIP experimental design comprises of multiple MIPs facilitating research in different focus areas. This paradigm has implications not only for the groups that develop the models and conduct the runs, but also for the groups that monitor, analyze and quality control the datasets before data publishing, before their knowledge makes its way into reports like the IPCC (Intergovernmental Panel on Climate Change) Assessment Reports. In this talk, we discuss some of the paths taken at GFDL to quality control the CMIP-ready datasets including: Jupyter notebooks, PrePARE, LAMP (Linux, Apache, MySQL, PHP/Python/Perl): technology-driven tracker system to monitor the status of experiments qualitatively and quantitatively, provide additional metadata and analysis services along with some in-built controlled-vocabulary validations in the workflow. In addition to this, we also discuss the integration of community-based model evaluation software (ESMValTool, PCMDI Metrics Package, and ILAMB) as part of our CMIP6 workflow.

  12. 40 CFR 81.76 - State of Hawaii Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 17 2011-07-01 2011-07-01 false State of Hawaii Air Quality Control... PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.76 State of Hawaii Air Quality Control Region. The State of Hawaii Air Quality...

  13. 40 CFR 81.76 - State of Hawaii Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false State of Hawaii Air Quality Control... PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.76 State of Hawaii Air Quality Control Region. The State of Hawaii Air Quality...

  14. 40 CFR 81.76 - State of Hawaii Air Quality Control Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 18 2012-07-01 2012-07-01 false State of Hawaii Air Quality Control... PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.76 State of Hawaii Air Quality Control Region. The State of Hawaii Air Quality...

  15. 40 CFR 81.76 - State of Hawaii Air Quality Control Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 18 2013-07-01 2013-07-01 false State of Hawaii Air Quality Control... PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.76 State of Hawaii Air Quality Control Region. The State of Hawaii Air Quality...

  16. A multichannel amplitude and relative-phase controller for active sound quality control

    NASA Astrophysics Data System (ADS)

    Mosquera-Sánchez, Jaime A.; Desmet, Wim; de Oliveira, Leopoldo P. R.

    2017-05-01

    The enhancement of the sound quality of periodic disturbances for a number of listeners within an enclosure often confronts difficulties given by cross-channel interferences, which arise from simultaneously profiling the primary sound at each error sensor. These interferences may deteriorate the original sound among each listener, which is an unacceptable result from the point of view of sound quality control. In this paper we provide experimental evidence on controlling both amplitude and relative-phase functions of stationary complex primary sounds for a number of listeners within a cavity, attaining amplifications of twice the original value, reductions on the order of 70 dB, and relative-phase shifts between ± π rad, still in a free-of-interference control scenario. To accomplish such burdensome control targets, we have designed a multichannel active sound profiling scheme that bases its operation on exchanging time-domain control signals among the control units during uptime. Provided the real parts of the eigenvalues of persistently excited control matrices are positive, the proposed multichannel array is able to counterbalance cross-channel interferences, while attaining demanding control targets. Moreover, regularization of unstable control matrices is not seen to prevent the proposed array to provide free-of-interference amplitude and relative-phase control, but the system performance is degraded, as a function of the amount of regularization needed. The assessment of Loudness and Roughness metrics on the controlled primary sound proves that the proposed distributed control scheme noticeably outperforms current techniques, since active amplitude- and/or relative-phase-based enhancement of the auditory qualities of a primary sound no longer implies in causing interferences among different positions. In this regard, experimental results also confirm the effectiveness of the proposed scheme on stably enhancing the sound qualities of periodic sounds for

  17. Development of an electronic device quality aluminum antimonide (AlSb) semiconductor for solar cell applications

    DOEpatents

    Sherohman, John W; Yee, Jick Hong; Combs, III, Arthur W

    2014-11-11

    Electronic device quality Aluminum Antimonide (AlSb)-based single crystals produced by controlled atmospheric annealing are utilized in various configurations for solar cell applications. Like that of a GaAs-based solar cell devices, the AlSb-based solar cell devices as disclosed herein provides direct conversion of solar energy to electrical power.

  18. TECHNICAL GUIDANCE DOCUMENT: QUALITY ASSURANCE AND QUALITY CONTROL FOR WASTE CONTAINMENT FACILITIES

    EPA Science Inventory

    This Technical Guidance Document provides comprehensive guidance on procedures for quality assurance and quality control for waste containment facilities. he document includes a discussion of principles and concepts, compacted soil liners, soil drainage systems, geosynthetic drai...

  19. TECHNICAL GUIDANCE DOCUMENT: QUALITY ASSURANCE AND QUALITY CONTROL FOR WASTE CONTAINMENT FACILITIES

    EPA Science Inventory

    This Technical Guidance Document provides comprehensive guidance on procedures for quality assurance and quality control for waste containment facilities. The document includes a discussion of principles and concepts, compacted soil liners, soil drainage systems, geosynthetic dr...

  20. 40 CFR 75.21 - Quality assurance and quality control requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., as defined in § 72.2, k=2) of plus or minus 1.0 percent (calculated combined standard uncertainty of... system according to the quality assurance and quality control procedures in appendix B of this part. (2... requirements of Method 2, 6C, 7E, or 3A in Appendices A-1, A-2 and A-4 to part 60 of this chapter (supplemented...

  1. Internal quality control: planning and implementation strategies.

    PubMed

    Westgard, James O

    2003-11-01

    The first essential in setting up internal quality control (IQC) of a test procedure in the clinical laboratory is to select the proper IQC procedure to implement, i.e. choosing the statistical criteria or control rules, and the number of control measurements, according to the quality required for the test and the observed performance of the method. Then the right IQC procedure must be properly implemented. This review focuses on strategies for planning and implementing IQC procedures in order to improve the quality of the IQC. A quantitative planning process is described that can be implemented with graphical tools such as power function or critical-error graphs and charts of operating specifications. Finally, a total QC strategy is formulated to minimize cost and maximize quality. A general strategy for IQC implementation is recommended that employs a three-stage design in which the first stage provides high error detection, the second stage low false rejection and the third stage prescribes the length of the analytical run, making use of an algorithm involving the average of normal patients' data.

  2. Aggregative Learning Method and Its Application for Communication Quality Evaluation

    NASA Astrophysics Data System (ADS)

    Akhmetov, Dauren F.; Kotaki, Minoru

    2007-12-01

    In this paper, so-called Aggregative Learning Method (ALM) is proposed to improve and simplify the learning and classification abilities of different data processing systems. It provides a universal basis for design and analysis of mathematical models of wide class. A procedure was elaborated for time series model reconstruction and analysis for linear and nonlinear cases. Data approximation accuracy (during learning phase) and data classification quality (during recall phase) are estimated from introduced statistic parameters. The validity and efficiency of the proposed approach have been demonstrated through its application for monitoring of wireless communication quality, namely, for Fixed Wireless Access (FWA) system. Low memory and computation resources were shown to be needed for the procedure realization, especially for data classification (recall) stage. Characterized with high computational efficiency and simple decision making procedure, the derived approaches can be useful for simple and reliable real-time surveillance and control system design.

  3. Close-range photogrammetry for aircraft quality control

    NASA Astrophysics Data System (ADS)

    Schwartz, D. S.

    Close range photogrammetry is applicable to quality assurance inspections, design data acquisition, and test management support tasks, yielding significant cost avoidance and increased productivity. An understanding of mensuration parameters and their related accuracies is fundamental to the successful application of industrial close range photogrammetry. Attention is presently given to these parameters and to the use of computer modelling as an aid to the photogrammetric entrepreneur in industry. Suggested improvements to cameras and film readers for industrial applications are discussed.

  4. [Quality control of Maca (Lepidium meyenii)].

    PubMed

    Shu, Ji-cheng; Cui, Hang-qing; Huang, Ying-zheng; Huang, Xiao-ying; Yang, Ming

    2015-12-01

    To control the quality of Maca, the quality standard was established in this study. According to the methods recorded in the Appendix of Chinese Pharmacopoeia (2010 Edition), the water, extract, total ash, acid insoluble substance, and heavy metals inspections in Lepidium meyenii were carried out. N-benzyl-9Z, 12Z-octadecadienamide in L. meyenii was identified by TLC, and it was determined by HPLC. The results showed that the N-benzyl-9Z, 12Z-octadecadienamide identification of TLC was a strong mark and specificity. In content determination experiment, the linearity of N-benzyl-9Z, 12Z-octadecadienamide was in the range of 0.01-2 microg (r = 0.9998), and the average recovery (n=9) was 99.27% (RSD 2.0%). The methods were simple, accurate, with good reproducibility. It is suitable for quality control L. meyenii.

  5. Flexible optical metrology strategies for the control and quality assurance of small series production

    NASA Astrophysics Data System (ADS)

    Schmitt, R.; Pavim, A.

    2009-06-01

    The demand for achieving smaller and more flexible production series with a considerable diversity of products complicates the control of the manufacturing tasks, leading to big challenges for the quality assurance systems. The quality assurance strategy that is nowadays used for mass production is unable to cope with the inspection flexibility needed among automated small series production, because the measuring strategy is totally dependent on the fixed features of the few manufactured object variants and on process parameters that can be controlled/compensated during production time. The major challenge faced by a quality assurance system applied to small series production facilities is to guarantee the needed quality level already at the first run, and therefore, the quality assurance system has to adapt itself constantly to the new manufacturing conditions. The small series production culture requires a change of paradigms, because its strategies are totally different from mass production. This work discusses the tight inspection requirements of small series production and presents flexible metrology strategies based on optical sensor data fusion techniques, agent-based systems as well as cognitive and self-optimised systems for assuring the needed quality level of flexible small series. Examples of application scenarios are provided among the automated assembly of solid state lasers and the flexible inspection of automotive headlights.

  6. 40 CFR 81.42 - Chattanooga Interstate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Chattanooga Interstate Air Quality...) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.42 Chattanooga Interstate Air Quality Control Region. The Chattanooga...

  7. 40 CFR 81.35 - Louisville Interstate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Louisville Interstate Air Quality...) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.35 Louisville Interstate Air Quality Control Region. The Louisville...

  8. 40 CFR 81.36 - Maricopa Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Maricopa Intrastate Air Quality...) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.36 Maricopa Intrastate Air Quality Control Region. The Phoenix-Tucson...

  9. 40 CFR 81.51 - Portland Interstate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Portland Interstate Air Quality...) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.51 Portland Interstate Air Quality Control Region. The Portland Interstate...

  10. 40 CFR 81.36 - Maricopa Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 17 2011-07-01 2011-07-01 false Maricopa Intrastate Air Quality...) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.36 Maricopa Intrastate Air Quality Control Region. The Phoenix-Tucson...

  11. 40 CFR 81.42 - Chattanooga Interstate Air Quality Control Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 18 2013-07-01 2013-07-01 false Chattanooga Interstate Air Quality...) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.42 Chattanooga Interstate Air Quality Control Region. The Chattanooga...

  12. 40 CFR 81.51 - Portland Interstate Air Quality Control Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 18 2013-07-01 2013-07-01 false Portland Interstate Air Quality...) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.51 Portland Interstate Air Quality Control Region. The Portland Interstate...

  13. 40 CFR 81.35 - Louisville Interstate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 17 2011-07-01 2011-07-01 false Louisville Interstate Air Quality...) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.35 Louisville Interstate Air Quality Control Region. The Louisville...

  14. 40 CFR 81.36 - Maricopa Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 18 2012-07-01 2012-07-01 false Maricopa Intrastate Air Quality...) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.36 Maricopa Intrastate Air Quality Control Region. The Phoenix-Tucson...

  15. 40 CFR 81.42 - Chattanooga Interstate Air Quality Control Region.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 18 2014-07-01 2014-07-01 false Chattanooga Interstate Air Quality...) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.42 Chattanooga Interstate Air Quality Control Region. The Chattanooga...

  16. 40 CFR 81.36 - Maricopa Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 18 2014-07-01 2014-07-01 false Maricopa Intrastate Air Quality...) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.36 Maricopa Intrastate Air Quality Control Region. The Phoenix-Tucson...

  17. 40 CFR 81.42 - Chattanooga Interstate Air Quality Control Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 18 2012-07-01 2012-07-01 false Chattanooga Interstate Air Quality...) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.42 Chattanooga Interstate Air Quality Control Region. The Chattanooga...

  18. 40 CFR 81.35 - Louisville Interstate Air Quality Control Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 18 2012-07-01 2012-07-01 false Louisville Interstate Air Quality...) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.35 Louisville Interstate Air Quality Control Region. The Louisville...

  19. 40 CFR 81.36 - Maricopa Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 18 2013-07-01 2013-07-01 false Maricopa Intrastate Air Quality...) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.36 Maricopa Intrastate Air Quality Control Region. The Phoenix-Tucson...

  20. 40 CFR 81.42 - Chattanooga Interstate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 17 2011-07-01 2011-07-01 false Chattanooga Interstate Air Quality...) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.42 Chattanooga Interstate Air Quality Control Region. The Chattanooga...

  1. 40 CFR 81.35 - Louisville Interstate Air Quality Control Region.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 18 2014-07-01 2014-07-01 false Louisville Interstate Air Quality...) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.35 Louisville Interstate Air Quality Control Region. The Louisville...

  2. 40 CFR 81.35 - Louisville Interstate Air Quality Control Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 18 2013-07-01 2013-07-01 false Louisville Interstate Air Quality...) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.35 Louisville Interstate Air Quality Control Region. The Louisville...

  3. 40 CFR 81.90 - Androscoggin Valley Interstate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.90 Section 81.90 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.90 Androscoggin Valley Interstate Air Quality Control Region. The...

  4. 40 CFR 81.90 - Androscoggin Valley Interstate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.90 Section 81.90 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.90 Androscoggin Valley Interstate Air Quality Control Region. The...

  5. 40 CFR 81.43 - Metropolitan Toledo Interstate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.43 Metropolitan Toledo Interstate Air Quality Control Region. The Metropolitan Toledo Interstate Air Quality Control Region (Ohio-Michigan) consists of the territorial area...

  6. 40 CFR 81.75 - Metropolitan Charlotte Interstate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.75 Metropolitan Charlotte Interstate Air Quality Control Region. The Metropolitan Charlotte Interstate Air Quality Control Region (North Carolina-South Carolina) has been revised...

  7. 40 CFR 81.47 - Central Oklahoma Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.47 Central Oklahoma Intrastate Air Quality Control Region. The Metropolitan Oklahoma Intrastate Air Quality Control Region has been renamed the Central Oklahoma Intrastate...

  8. 40 CFR 81.44 - Metropolitan Memphis Interstate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.44 Metropolitan Memphis Interstate Air Quality Control Region. The Metropolitan Memphis Interstate Air Quality Control Region (Arkansas-Mississippi-Tennessee) consists of the...

  9. 40 CFR 81.16 - Metropolitan Denver Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.16 Metropolitan Denver Intrastate Air Quality Control Region. The Metropolitan Denver Intrastate Air Quality Control Region (Colorado) consists of the territorial area...

  10. 40 CFR 81.24 - Niagara Frontier Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.24 Niagara Frontier Intrastate Air Quality Control Region. The Niagara Frontier Intrastate Air Quality Control Region (New York) consists of the territorial area...

  11. 40 CFR 81.28 - Metropolitan Baltimore Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.28 Metropolitan Baltimore Intrastate Air Quality Control Region. The Metropolitan Baltimore Intrastate Air Quality Control Region (Maryland) consists of the territorial area...

  12. 40 CFR 81.23 - Southwest Pennsylvania Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.23 Southwest Pennsylvania Intrastate Air Quality Control Region. The Southwest Pennsylvania Intrastate Air Quality Control Region is redesignated to consist of the territorial...

  13. 40 CFR 81.30 - Southeastern Wisconsin Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.30 Southeastern Wisconsin Intrastate Air Quality Control Region. The Metropolitan Milwaukee Intrastate Air Quality Control Region (Wisconsin) has been renamed the Southeastern...

  14. 40 CFR 81.19 - Metropolitan Boston Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.19 Metropolitan Boston Intrastate Air Quality Control Region. The Metropolitan Boston Intrastate Air Quality Control Region (Massachusetts) consists of the territorial area...

  15. 40 CFR 81.29 - Metropolitan Indianapolis Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Air Quality Control Region. 81.29 Section 81.29 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.29 Metropolitan Indianapolis Intrastate Air Quality Control...

  16. 40 CFR 81.78 - Metropolitan Portland Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.78 Metropolitan Portland Intrastate Air Quality Control Region. The Metropolitan Portland Intrastate Air Quality Control Region (Maine) consists of the territorial area...

  17. 40 CFR 81.62 - Northeast Mississippi Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.62 Northeast Mississippi Intrastate Air Quality Control Region. The Alabama-Mississippi-Tennessee Interstate Air Quality Control Region has been renamed the Northeast...

  18. 40 CFR 81.31 - Metropolitan Providence Interstate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.31 Metropolitan Providence Interstate Air Quality Control Region. The Metropolitan Providence Interstate Air Quality Control Region (Rhode Island-Massachusetts) consists of the...

  19. 40 CFR 81.75 - Metropolitan Charlotte Interstate Air Quality Control Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.75 Metropolitan Charlotte Interstate Air Quality Control Region. The Metropolitan Charlotte Interstate Air Quality Control Region (North Carolina-South Carolina) has been revised...

  20. 40 CFR 81.16 - Metropolitan Denver Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.16 Metropolitan Denver Intrastate Air Quality Control Region. The Metropolitan Denver Intrastate Air Quality Control Region (Colorado) consists of the territorial area...

  1. 40 CFR 81.24 - Niagara Frontier Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.24 Niagara Frontier Intrastate Air Quality Control Region. The Niagara Frontier Intrastate Air Quality Control Region (New York) consists of the territorial area...

  2. 40 CFR 81.43 - Metropolitan Toledo Interstate Air Quality Control Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.43 Metropolitan Toledo Interstate Air Quality Control Region. The Metropolitan Toledo Interstate Air Quality Control Region (Ohio-Michigan) consists of the territorial area...

  3. 40 CFR 81.62 - Northeast Mississippi Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.62 Northeast Mississippi Intrastate Air Quality Control Region. The Alabama-Mississippi-Tennessee Interstate Air Quality Control Region has been renamed the Northeast...

  4. 40 CFR 81.16 - Metropolitan Denver Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.16 Metropolitan Denver Intrastate Air Quality Control Region. The Metropolitan Denver Intrastate Air Quality Control Region (Colorado) consists of the territorial area...

  5. 40 CFR 81.47 - Central Oklahoma Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.47 Central Oklahoma Intrastate Air Quality Control Region. The Metropolitan Oklahoma Intrastate Air Quality Control Region has been renamed the Central Oklahoma Intrastate...

  6. 40 CFR 81.31 - Metropolitan Providence Interstate Air Quality Control Region.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.31 Metropolitan Providence Interstate Air Quality Control Region. The Metropolitan Providence Interstate Air Quality Control Region (Rhode Island-Massachusetts) consists of the...

  7. 40 CFR 81.23 - Southwest Pennsylvania Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.23 Southwest Pennsylvania Intrastate Air Quality Control Region. The Southwest Pennsylvania Intrastate Air Quality Control Region is redesignated to consist of the territorial...

  8. 40 CFR 81.16 - Metropolitan Denver Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.16 Metropolitan Denver Intrastate Air Quality Control Region. The Metropolitan Denver Intrastate Air Quality Control Region (Colorado) consists of the territorial area...

  9. 40 CFR 81.79 - Northeastern Oklahoma Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.79 Northeastern Oklahoma Intrastate Air Quality Control Region. The Metropolitan Tulsa Intrastate Air Quality Control Region has been renamed the Northeastern Oklahoma Intrastate...

  10. 40 CFR 81.30 - Southeastern Wisconsin Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.30 Southeastern Wisconsin Intrastate Air Quality Control Region. The Metropolitan Milwaukee Intrastate Air Quality Control Region (Wisconsin) has been renamed the Southeastern...

  11. 40 CFR 81.31 - Metropolitan Providence Interstate Air Quality Control Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.31 Metropolitan Providence Interstate Air Quality Control Region. The Metropolitan Providence Interstate Air Quality Control Region (Rhode Island-Massachusetts) consists of the...

  12. 40 CFR 81.62 - Northeast Mississippi Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.62 Northeast Mississippi Intrastate Air Quality Control Region. The Alabama-Mississippi-Tennessee Interstate Air Quality Control Region has been renamed the Northeast...

  13. 40 CFR 81.28 - Metropolitan Baltimore Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.28 Metropolitan Baltimore Intrastate Air Quality Control Region. The Metropolitan Baltimore Intrastate Air Quality Control Region (Maryland) consists of the territorial area...

  14. 40 CFR 81.78 - Metropolitan Portland Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.78 Metropolitan Portland Intrastate Air Quality Control Region. The Metropolitan Portland Intrastate Air Quality Control Region (Maine) consists of the territorial area...

  15. 40 CFR 81.78 - Metropolitan Portland Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.78 Metropolitan Portland Intrastate Air Quality Control Region. The Metropolitan Portland Intrastate Air Quality Control Region (Maine) consists of the territorial area...

  16. 40 CFR 81.28 - Metropolitan Baltimore Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.28 Metropolitan Baltimore Intrastate Air Quality Control Region. The Metropolitan Baltimore Intrastate Air Quality Control Region (Maryland) consists of the territorial area...

  17. 40 CFR 81.62 - Northeast Mississippi Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.62 Northeast Mississippi Intrastate Air Quality Control Region. The Alabama-Mississippi-Tennessee Interstate Air Quality Control Region has been renamed the Northeast...

  18. 40 CFR 81.28 - Metropolitan Baltimore Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.28 Metropolitan Baltimore Intrastate Air Quality Control Region. The Metropolitan Baltimore Intrastate Air Quality Control Region (Maryland) consists of the territorial area...

  19. 40 CFR 81.30 - Southeastern Wisconsin Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.30 Southeastern Wisconsin Intrastate Air Quality Control Region. The Metropolitan Milwaukee Intrastate Air Quality Control Region (Wisconsin) has been renamed the Southeastern...

  20. 40 CFR 81.43 - Metropolitan Toledo Interstate Air Quality Control Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.43 Metropolitan Toledo Interstate Air Quality Control Region. The Metropolitan Toledo Interstate Air Quality Control Region (Ohio-Michigan) consists of the territorial area...

  1. 40 CFR 81.24 - Niagara Frontier Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.24 Niagara Frontier Intrastate Air Quality Control Region. The Niagara Frontier Intrastate Air Quality Control Region (New York) consists of the territorial area...

  2. 40 CFR 81.29 - Metropolitan Indianapolis Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Air Quality Control Region. 81.29 Section 81.29 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.29 Metropolitan Indianapolis Intrastate Air Quality Control...

  3. 40 CFR 81.31 - Metropolitan Providence Interstate Air Quality Control Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.31 Metropolitan Providence Interstate Air Quality Control Region. The Metropolitan Providence Interstate Air Quality Control Region (Rhode Island-Massachusetts) consists of the...

  4. 40 CFR 81.47 - Central Oklahoma Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.47 Central Oklahoma Intrastate Air Quality Control Region. The Metropolitan Oklahoma Intrastate Air Quality Control Region has been renamed the Central Oklahoma Intrastate...

  5. 40 CFR 81.23 - Southwest Pennsylvania Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.23 Southwest Pennsylvania Intrastate Air Quality Control Region. The Southwest Pennsylvania Intrastate Air Quality Control Region is redesignated to consist of the territorial...

  6. 40 CFR 81.29 - Metropolitan Indianapolis Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Air Quality Control Region. 81.29 Section 81.29 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.29 Metropolitan Indianapolis Intrastate Air Quality Control...

  7. 40 CFR 81.44 - Metropolitan Memphis Interstate Air Quality Control Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.44 Metropolitan Memphis Interstate Air Quality Control Region. The Metropolitan Memphis Interstate Air Quality Control Region (Arkansas-Mississippi-Tennessee) consists of the...

  8. 40 CFR 81.30 - Southeastern Wisconsin Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.30 Southeastern Wisconsin Intrastate Air Quality Control Region. The Metropolitan Milwaukee Intrastate Air Quality Control Region (Wisconsin) has been renamed the Southeastern...

  9. 40 CFR 81.47 - Central Oklahoma Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.47 Central Oklahoma Intrastate Air Quality Control Region. The Metropolitan Oklahoma Intrastate Air Quality Control Region has been renamed the Central Oklahoma Intrastate...

  10. 40 CFR 81.23 - Southwest Pennsylvania Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.23 Southwest Pennsylvania Intrastate Air Quality Control Region. The Southwest Pennsylvania Intrastate Air Quality Control Region is redesignated to consist of the territorial...

  11. 40 CFR 81.43 - Metropolitan Toledo Interstate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.43 Metropolitan Toledo Interstate Air Quality Control Region. The Metropolitan Toledo Interstate Air Quality Control Region (Ohio-Michigan) consists of the territorial area...

  12. 40 CFR 81.30 - Southeastern Wisconsin Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.30 Southeastern Wisconsin Intrastate Air Quality Control Region. The Metropolitan Milwaukee Intrastate Air Quality Control Region (Wisconsin) has been renamed the Southeastern...

  13. 40 CFR 81.24 - Niagara Frontier Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.24 Niagara Frontier Intrastate Air Quality Control Region. The Niagara Frontier Intrastate Air Quality Control Region (New York) consists of the territorial area...

  14. 40 CFR 81.43 - Metropolitan Toledo Interstate Air Quality Control Region.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.43 Metropolitan Toledo Interstate Air Quality Control Region. The Metropolitan Toledo Interstate Air Quality Control Region (Ohio-Michigan) consists of the territorial area...

  15. 40 CFR 81.75 - Metropolitan Charlotte Interstate Air Quality Control Region.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.75 Metropolitan Charlotte Interstate Air Quality Control Region. The Metropolitan Charlotte Interstate Air Quality Control Region (North Carolina-South Carolina) has been revised...

  16. 40 CFR 81.28 - Metropolitan Baltimore Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.28 Metropolitan Baltimore Intrastate Air Quality Control Region. The Metropolitan Baltimore Intrastate Air Quality Control Region (Maryland) consists of the territorial area...

  17. 40 CFR 81.29 - Metropolitan Indianapolis Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Air Quality Control Region. 81.29 Section 81.29 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.29 Metropolitan Indianapolis Intrastate Air Quality Control...

  18. 40 CFR 81.19 - Metropolitan Boston Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.19 Metropolitan Boston Intrastate Air Quality Control Region. The Metropolitan Boston Intrastate Air Quality Control Region (Massachusetts) consists of the territorial area...

  19. 40 CFR 81.19 - Metropolitan Boston Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.19 Metropolitan Boston Intrastate Air Quality Control Region. The Metropolitan Boston Intrastate Air Quality Control Region (Massachusetts) consists of the territorial area...

  20. 40 CFR 81.44 - Metropolitan Memphis Interstate Air Quality Control Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.44 Metropolitan Memphis Interstate Air Quality Control Region. The Metropolitan Memphis Interstate Air Quality Control Region (Arkansas-Mississippi-Tennessee) consists of the...

  1. 40 CFR 81.24 - Niagara Frontier Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.24 Niagara Frontier Intrastate Air Quality Control Region. The Niagara Frontier Intrastate Air Quality Control Region (New York) consists of the territorial area...

  2. 40 CFR 81.16 - Metropolitan Denver Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.16 Metropolitan Denver Intrastate Air Quality Control Region. The Metropolitan Denver Intrastate Air Quality Control Region (Colorado) consists of the territorial area...

  3. 40 CFR 81.19 - Metropolitan Boston Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.19 Metropolitan Boston Intrastate Air Quality Control Region. The Metropolitan Boston Intrastate Air Quality Control Region (Massachusetts) consists of the territorial area...

  4. 40 CFR 81.23 - Southwest Pennsylvania Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.23 Southwest Pennsylvania Intrastate Air Quality Control Region. The Southwest Pennsylvania Intrastate Air Quality Control Region is redesignated to consist of the territorial...

  5. 40 CFR 81.19 - Metropolitan Boston Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.19 Metropolitan Boston Intrastate Air Quality Control Region. The Metropolitan Boston Intrastate Air Quality Control Region (Massachusetts) consists of the territorial area...

  6. 40 CFR 81.87 - Metropolitan Boise Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.87 Metropolitan Boise Intrastate Air Quality Control Region. The Metropolitan Boise Intrastate Air Quality Control Region (Idaho) consists of the territorial area encompassed...

  7. 40 CFR 81.47 - Central Oklahoma Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.47 Central Oklahoma Intrastate Air Quality Control Region. The Metropolitan Oklahoma Intrastate Air Quality Control Region has been renamed the Central Oklahoma Intrastate...

  8. 40 CFR 81.75 - Metropolitan Charlotte Interstate Air Quality Control Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.75 Metropolitan Charlotte Interstate Air Quality Control Region. The Metropolitan Charlotte Interstate Air Quality Control Region (North Carolina-South Carolina) has been revised...

  9. 40 CFR 81.29 - Metropolitan Indianapolis Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Air Quality Control Region. 81.29 Section 81.29 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.29 Metropolitan Indianapolis Intrastate Air Quality Control...

  10. 40 CFR 81.79 - Northeastern Oklahoma Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.79 Northeastern Oklahoma Intrastate Air Quality Control Region. The Metropolitan Tulsa Intrastate Air Quality Control Region has been renamed the Northeastern Oklahoma Intrastate...

  11. 40 CFR 81.44 - Metropolitan Memphis Interstate Air Quality Control Region.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.44 Metropolitan Memphis Interstate Air Quality Control Region. The Metropolitan Memphis Interstate Air Quality Control Region (Arkansas-Mississippi-Tennessee) consists of the...

  12. 40 CFR 81.31 - Metropolitan Providence Interstate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.31 Metropolitan Providence Interstate Air Quality Control Region. The Metropolitan Providence Interstate Air Quality Control Region (Rhode Island-Massachusetts) consists of the...

  13. 40 CFR 81.44 - Metropolitan Memphis Interstate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.44 Metropolitan Memphis Interstate Air Quality Control Region. The Metropolitan Memphis Interstate Air Quality Control Region (Arkansas-Mississippi-Tennessee) consists of the...

  14. The application of quality risk management to the bacterial endotoxins test: use of hazard analysis and critical control points.

    PubMed

    Annalaura, Carducci; Giulia, Davini; Stefano, Ceccanti

    2013-01-01

    Risk analysis is widely used in the pharmaceutical industry to manage production processes, validation activities, training, and other activities. Several methods of risk analysis are available (for example, failure mode and effects analysis, fault tree analysis), and one or more should be chosen and adapted to the specific field where they will be applied. Among the methods available, hazard analysis and critical control points (HACCP) is a methodology that has been applied since the 1960s, and whose areas of application have expanded over time from food to the pharmaceutical industry. It can be easily and successfully applied to several processes because its main feature is the identification, assessment, and control of hazards. It can be also integrated with other tools, such as fishbone diagram and flowcharting. The aim of this article is to show how HACCP can be used to manage an analytical process, propose how to conduct the necessary steps, and provide data templates necessary to document and useful to follow current good manufacturing practices. In the quality control process, risk analysis is a useful tool for enhancing the uniformity of technical choices and their documented rationale. Accordingly, it allows for more effective and economical laboratory management, is capable of increasing the reliability of analytical results, and enables auditors and authorities to better understand choices that have been made. The aim of this article is to show how hazard analysis and critical control points can be used to manage bacterial endotoxins testing and other analytical processes in a formal, clear, and detailed manner.

  15. Defining the best quality-control systems by design and inspection.

    PubMed

    Hinckley, C M

    1997-05-01

    Not all of the many approaches to quality control are equally effective. Nonconformities in laboratory testing are caused basically by excessive process variation and mistakes. Statistical quality control can effectively control process variation, but it cannot detect or prevent most mistakes. Because mistakes or blunders are frequently the dominant source of nonconformities, we conclude that statistical quality control by itself is not effective. I explore the 100% inspection methods essential for controlling mistakes. Unlike the inspection techniques that Deming described as ineffective, the new "source" inspection methods can detect mistakes and enable corrections before nonconformities are generated, achieving the highest degree of quality at a fraction of the cost of traditional methods. Key relationships between task complexity and nonconformity rates are also described, along with cultural changes that are essential for implementing the best quality-control practices.

  16. Statistical quality control through overall vibration analysis

    NASA Astrophysics Data System (ADS)

    Carnero, M. a. Carmen; González-Palma, Rafael; Almorza, David; Mayorga, Pedro; López-Escobar, Carlos

    2010-05-01

    The present study introduces the concept of statistical quality control in automotive wheel bearings manufacturing processes. Defects on products under analysis can have a direct influence on passengers' safety and comfort. At present, the use of vibration analysis on machine tools for quality control purposes is not very extensive in manufacturing facilities. Noise and vibration are common quality problems in bearings. These failure modes likely occur under certain operating conditions and do not require high vibration amplitudes but relate to certain vibration frequencies. The vibration frequencies are affected by the type of surface problems (chattering) of ball races that are generated through grinding processes. The purpose of this paper is to identify grinding process variables that affect the quality of bearings by using statistical principles in the field of machine tools. In addition, an evaluation of the quality results of the finished parts under different combinations of process variables is assessed. This paper intends to establish the foundations to predict the quality of the products through the analysis of self-induced vibrations during the contact between the grinding wheel and the parts. To achieve this goal, the overall self-induced vibration readings under different combinations of process variables are analysed using statistical tools. The analysis of data and design of experiments follows a classical approach, considering all potential interactions between variables. The analysis of data is conducted through analysis of variance (ANOVA) for data sets that meet normality and homoscedasticity criteria. This paper utilizes different statistical tools to support the conclusions such as chi squared, Shapiro-Wilks, symmetry, Kurtosis, Cochran, Hartlett, and Hartley and Krushal-Wallis. The analysis presented is the starting point to extend the use of predictive techniques (vibration analysis) for quality control. This paper demonstrates the existence

  17. 30 CFR 28.31 - Quality control plans; contents.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 28.31 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING... PROTECTION FOR TRAILING CABLES IN COAL MINES Quality Control § 28.31 Quality control plans; contents. (a... Specification MIL-F-15160D is available for examination at the U.S. Department of Labor, Mine Safety and Health...

  18. 30 CFR 28.31 - Quality control plans; contents.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 28.31 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING... PROTECTION FOR TRAILING CABLES IN COAL MINES Quality Control § 28.31 Quality control plans; contents. (a... Specification MIL-F-15160D is available for examination at the U.S. Department of Labor, Mine Safety and Health...

  19. 30 CFR 28.31 - Quality control plans; contents.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 28.31 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING... PROTECTION FOR TRAILING CABLES IN COAL MINES Quality Control § 28.31 Quality control plans; contents. (a... Specification MIL-F-15160D is available for examination at the U.S. Department of Labor, Mine Safety and Health...

  20. 30 CFR 28.31 - Quality control plans; contents.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 28.31 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING... PROTECTION FOR TRAILING CABLES IN COAL MINES Quality Control § 28.31 Quality control plans; contents. (a... Specification MIL-F-15160D is available for examination at the U.S. Department of Labor, Mine Safety and Health...

  1. NASA Earth Observation Systems and Applications for Health and Air Quality

    NASA Technical Reports Server (NTRS)

    Omar, Ali H.

    2015-01-01

    There is a growing body of evidence that the environment can affect human health in ways that are both complex and global in scope. To address some of these complexities, NASA maintains a diverse constellation of Earth observing research satellites, and sponsors research in developing satellite data applications across a wide spectrum of areas. These include environmental health; infectious disease; air quality standards, policies, and regulations; and the impact of climate change on health and air quality in a number of interrelated efforts. The Health and Air Quality Applications fosters the use of observations, modeling systems, forecast development, application integration, and the research to operations transition process to address environmental health effects. NASA has been a primary partner with Federal operational agencies over the past nine years in these areas. This talk presents the background of the Health and Air Quality Applications program, recent accomplishments, and a plan for the future.

  2. 40 CFR 81.49 - Southeast Florida Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.49 Southeast Florida Intrastate Air Quality Control Region. The Southeast Florida Intrastate Air Quality Control Region is redesignated to consist of the territorial area...

  3. 40 CFR 81.20 - Metropolitan Cincinnati Interstate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.20 Metropolitan Cincinnati Interstate Air Quality Control Region. The Metropolitan Cincinnati Interstate Air Quality Control Region (Ohio-Kentucky-Indiana) is revised to consist of...

  4. 40 CFR 81.59 - Cumberland-Keyser Interstate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.59 Cumberland-Keyser Interstate Air Quality Control Region. The Cumberland-Keyser Interstate Air Quality Control Region (Maryland-West Virginia) has been revised to consist...

  5. 40 CFR 81.14 - Metropolitan Chicago Interstate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.14 Metropolitan Chicago Interstate Air Quality Control Region. The Metropolitan Chicago Interstate Air Quality Control Region (Illinois-Indiana) is revised to consist of the...

  6. 40 CFR 81.45 - Metropolitan Atlanta Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.45 Metropolitan Atlanta Intrastate Air Quality Control Region. The Metropolitan Atlanta Intrastate Air Quality Control Region (Georgia) has been revised to consist of the...

  7. 40 CFR 81.41 - Metropolitan Birmingham Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.41 Metropolitan Birmingham Intrastate Air Quality Control Region. The Metropolitan Birmingham Intrastate Air Quality Control Region (Alabama) has been revised to consist of the...

  8. 40 CFR 81.34 - Metropolitan Dayton Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.34 Metropolitan Dayton Intrastate Air Quality Control Region. The Metropolitan Dayton Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  9. 40 CFR 81.45 - Metropolitan Atlanta Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.45 Metropolitan Atlanta Intrastate Air Quality Control Region. The Metropolitan Atlanta Intrastate Air Quality Control Region (Georgia) has been revised to consist of the...

  10. 40 CFR 81.34 - Metropolitan Dayton Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.34 Metropolitan Dayton Intrastate Air Quality Control Region. The Metropolitan Dayton Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  11. 40 CFR 81.45 - Metropolitan Atlanta Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.45 Metropolitan Atlanta Intrastate Air Quality Control Region. The Metropolitan Atlanta Intrastate Air Quality Control Region (Georgia) has been revised to consist of the...

  12. 40 CFR 81.41 - Metropolitan Birmingham Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.41 Metropolitan Birmingham Intrastate Air Quality Control Region. The Metropolitan Birmingham Intrastate Air Quality Control Region (Alabama) has been revised to consist of the...

  13. 40 CFR 81.34 - Metropolitan Dayton Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.34 Metropolitan Dayton Intrastate Air Quality Control Region. The Metropolitan Dayton Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  14. 40 CFR 81.41 - Metropolitan Birmingham Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.41 Metropolitan Birmingham Intrastate Air Quality Control Region. The Metropolitan Birmingham Intrastate Air Quality Control Region (Alabama) has been revised to consist of the...

  15. 40 CFR 81.20 - Metropolitan Cincinnati Interstate Air Quality Control Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.20 Metropolitan Cincinnati Interstate Air Quality Control Region. The Metropolitan Cincinnati Interstate Air Quality Control Region (Ohio-Kentucky-Indiana) is revised to consist of...

  16. 40 CFR 81.34 - Metropolitan Dayton Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.34 Metropolitan Dayton Intrastate Air Quality Control Region. The Metropolitan Dayton Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  17. 40 CFR 81.59 - Cumberland-Keyser Interstate Air Quality Control Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.59 Cumberland-Keyser Interstate Air Quality Control Region. The Cumberland-Keyser Interstate Air Quality Control Region (Maryland-West Virginia) has been revised to consist...

  18. 40 CFR 81.49 - Southeast Florida Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.49 Southeast Florida Intrastate Air Quality Control Region. The Southeast Florida Intrastate Air Quality Control Region is redesignated to consist of the territorial area...

  19. 40 CFR 81.49 - Southeast Florida Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.49 Southeast Florida Intrastate Air Quality Control Region. The Southeast Florida Intrastate Air Quality Control Region is redesignated to consist of the territorial area...

  20. 40 CFR 81.41 - Metropolitan Birmingham Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.41 Metropolitan Birmingham Intrastate Air Quality Control Region. The Metropolitan Birmingham Intrastate Air Quality Control Region (Alabama) has been revised to consist of the...

  1. 40 CFR 81.41 - Metropolitan Birmingham Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.41 Metropolitan Birmingham Intrastate Air Quality Control Region. The Metropolitan Birmingham Intrastate Air Quality Control Region (Alabama) has been revised to consist of the...

  2. 40 CFR 81.34 - Metropolitan Dayton Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.34 Metropolitan Dayton Intrastate Air Quality Control Region. The Metropolitan Dayton Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  3. 40 CFR 81.49 - Southeast Florida Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.49 Southeast Florida Intrastate Air Quality Control Region. The Southeast Florida Intrastate Air Quality Control Region is redesignated to consist of the territorial area...

  4. 40 CFR 81.45 - Metropolitan Atlanta Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.45 Metropolitan Atlanta Intrastate Air Quality Control Region. The Metropolitan Atlanta Intrastate Air Quality Control Region (Georgia) has been revised to consist of the...

  5. 40 CFR 81.59 - Cumberland-Keyser Interstate Air Quality Control Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.59 Cumberland-Keyser Interstate Air Quality Control Region. The Cumberland-Keyser Interstate Air Quality Control Region (Maryland-West Virginia) has been revised to consist...

  6. 40 CFR 81.20 - Metropolitan Cincinnati Interstate Air Quality Control Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.20 Metropolitan Cincinnati Interstate Air Quality Control Region. The Metropolitan Cincinnati Interstate Air Quality Control Region (Ohio-Kentucky-Indiana) is revised to consist of...

  7. 40 CFR 81.20 - Metropolitan Cincinnati Interstate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.20 Metropolitan Cincinnati Interstate Air Quality Control Region. The Metropolitan Cincinnati Interstate Air Quality Control Region (Ohio-Kentucky-Indiana) is revised to consist of...

  8. 40 CFR 81.14 - Metropolitan Chicago Interstate Air Quality Control Region.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.14 Metropolitan Chicago Interstate Air Quality Control Region. The Metropolitan Chicago Interstate Air Quality Control Region (Illinois-Indiana) is revised to consist of the...

  9. 40 CFR 81.14 - Metropolitan Chicago Interstate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.14 Metropolitan Chicago Interstate Air Quality Control Region. The Metropolitan Chicago Interstate Air Quality Control Region (Illinois-Indiana) is revised to consist of the...

  10. 40 CFR 81.49 - Southeast Florida Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.49 Southeast Florida Intrastate Air Quality Control Region. The Southeast Florida Intrastate Air Quality Control Region is redesignated to consist of the territorial area...

  11. 40 CFR 81.14 - Metropolitan Chicago Interstate Air Quality Control Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.14 Metropolitan Chicago Interstate Air Quality Control Region. The Metropolitan Chicago Interstate Air Quality Control Region (Illinois-Indiana) is revised to consist of the...

  12. 40 CFR 81.20 - Metropolitan Cincinnati Interstate Air Quality Control Region.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.20 Metropolitan Cincinnati Interstate Air Quality Control Region. The Metropolitan Cincinnati Interstate Air Quality Control Region (Ohio-Kentucky-Indiana) is revised to consist of...

  13. 40 CFR 81.59 - Cumberland-Keyser Interstate Air Quality Control Region.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.59 Cumberland-Keyser Interstate Air Quality Control Region. The Cumberland-Keyser Interstate Air Quality Control Region (Maryland-West Virginia) has been revised to consist...

  14. 40 CFR 81.14 - Metropolitan Chicago Interstate Air Quality Control Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.14 Metropolitan Chicago Interstate Air Quality Control Region. The Metropolitan Chicago Interstate Air Quality Control Region (Illinois-Indiana) is revised to consist of the...

  15. 40 CFR 81.45 - Metropolitan Atlanta Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.45 Metropolitan Atlanta Intrastate Air Quality Control Region. The Metropolitan Atlanta Intrastate Air Quality Control Region (Georgia) has been revised to consist of the...

  16. 40 CFR 81.59 - Cumberland-Keyser Interstate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.59 Cumberland-Keyser Interstate Air Quality Control Region. The Cumberland-Keyser Interstate Air Quality Control Region (Maryland-West Virginia) has been revised to consist...

  17. Effectiveness Comparison of TxDOT Quality Control/Quality Assurance and Method Specifications

    DOT National Transportation Integrated Search

    1998-12-01

    Original Report date: October 1997. This is the first and final report for research project 0-1721, "Effectiveness Comparison of TxDOT Quality Control/Quality Assurance and Method Specifications." This study was established and sponsored by TxDOT to ...

  18. [Physical fingerprint for quality control of traditional Chinese medicine extract powders].

    PubMed

    Zhang, Yi; Xu, Bing; Sun, Fei; Wang, Xin; Zhang, Na; Shi, Xin-Yuan; Qiao, Yan-Jiang

    2016-06-01

    The physical properties of both raw materials and excipients are closely correlated with the quality of traditional Chinese medicine preparations in oral solid dosage forms. In this paper, based on the concept of the chemical fingerprint for quality control of traditional Chinese medicine products, the method of physical fingerprint for quality evaluation of traditional Chinese medicine extract powders was proposed. This novel physical fingerprint was built by the radar map, and consisted of five primary indexes (i.e. stackablity, homogeneity, flowability, compressibility and stability) and 12 secondary indexes (i.e. bulk density, tap density, particle size<50 μm percentage, relative homogeneity index, hausner ratio, angle of repose, powder flow time, inter-particle porosity, Carr index, cohesion index, loss on drying, hygroscopicity). Panax notoginseng saponins (PNS) extract was taken for an example. This paper introduced the application of physical fingerprint in the evaluation of source-to-source and batch-to-batch quality consistence of PNS extract powders. Moreover, the physical fingerprint of PNS was built by calculating the index of parameters, the index of parametric profile and the index of good compressibility, in order to successfully predict the compressibility of the PNS extract powder and relevant formulations containing PNS extract powder and conventional pharmaceutical excipients. The results demonstrated that the proposed method could not only provide new insights into the development and process control of traditional Chinese medicine solid dosage forms. Copyright© by the Chinese Pharmaceutical Association.

  19. 40 CFR 81.48 - Champlain Valley Interstate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.48 Champlain Valley Interstate Air Quality Control Region. The Champlain Valley Interstate Air Quality Control Region (Vermont-New York) has been revised to consist of the...

  20. 40 CFR 81.48 - Champlain Valley Interstate Air Quality Control Region.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.48 Champlain Valley Interstate Air Quality Control Region. The Champlain Valley Interstate Air Quality Control Region (Vermont-New York) has been revised to consist of the...