Sample records for quality control checks

  1. An Adaptive Buddy Check for Observational Quality Control

    NASA Technical Reports Server (NTRS)

    Dee, Dick P.; Rukhovets, Leonid; Todling, Ricardo; DaSilva, Arlindo M.; Larson, Jay W.; Einaudi, Franco (Technical Monitor)

    2000-01-01

    An adaptive buddy check algorithm is presented that adjusts tolerances for outlier observations based on the variability of surrounding data. The algorithm derives from a statistical hypothesis test combined with maximum-likelihood covariance estimation. Its stability is shown to depend on the initial identification of outliers by a simple background check. The adaptive feature ensures that the final quality control decisions are not very sensitive to prescribed statistics of first-guess and observation errors, nor on other approximations introduced into the algorithm. The implementation of the algorithm in a global atmospheric data assimilation is described. Its performance is contrasted with that of a non-adaptive buddy check, for the surface analysis of an extreme storm that took place in Europe on 27 December 1999. The adaptive algorithm allowed the inclusion of many important observations that differed greatly from the first guess and that would have been excluded on the basis of prescribed statistics. The analysis of the storm development was much improved as a result of these additional observations.

  2. Quality control quantification (QCQ): a tool to measure the value of quality control checks in radiation oncology.

    PubMed

    Ford, Eric C; Terezakis, Stephanie; Souranis, Annette; Harris, Kendra; Gay, Hiram; Mutic, Sasa

    2012-11-01

    To quantify the error-detection effectiveness of commonly used quality control (QC) measures. We analyzed incidents from 2007-2010 logged into a voluntary in-house, electronic incident learning systems at 2 academic radiation oncology clinics. None of the incidents resulted in patient harm. Each incident was graded for potential severity using the French Nuclear Safety Authority scoring scale; high potential severity incidents (score >3) were considered, along with a subset of 30 randomly chosen low severity incidents. Each report was evaluated to identify which of 15 common QC checks could have detected it. The effectiveness was calculated, defined as the percentage of incidents that each QC measure could detect, both for individual QC checks and for combinations of checks. In total, 4407 incidents were reported, 292 of which had high-potential severity. High- and low-severity incidents were detectable by 4.0 ± 2.3 (mean ± SD) and 2.6 ± 1.4 QC checks, respectively (P<.001). All individual checks were less than 50% sensitive with the exception of pretreatment plan review by a physicist (63%). An effectiveness of 97% was achieved with 7 checks used in combination and was not further improved with more checks. The combination of checks with the highest effectiveness includes physics plan review, physician plan review, Electronic Portal Imaging Device-based in vivo portal dosimetry, radiation therapist timeout, weekly physics chart check, the use of checklists, port films, and source-to-skin distance checks. Some commonly used QC checks such as pretreatment intensity modulated radiation therapy QA do not substantially add to the ability to detect errors in these data. The effectiveness of QC measures in radiation oncology depends sensitively on which checks are used and in which combinations. A small percentage of errors cannot be detected by any of the standard formal QC checks currently in broad use, suggesting that further improvements are needed. These data

  3. 7 CFR 58.243 - Checking quality.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Checking quality. 58.243 Section 58.243 Agriculture... Procedures § 58.243 Checking quality. All milk, milk products and dry milk products shall be subject to inspection and analysis by the dairy plant for quality and condition throughout each processing operation...

  4. Langley Wind Tunnel Data Quality Assurance-Check Standard Results

    NASA Technical Reports Server (NTRS)

    Hemsch, Michael J.; Grubb, John P.; Krieger, William B.; Cler, Daniel L.

    2000-01-01

    A framework for statistical evaluation, control and improvement of wind funnel measurement processes is presented The methodology is adapted from elements of the Measurement Assurance Plans developed by the National Bureau of Standards (now the National Institute of Standards and Technology) for standards and calibration laboratories. The present methodology is based on the notions of statistical quality control (SQC) together with check standard testing and a small number of customer repeat-run sets. The results of check standard and customer repeat-run -sets are analyzed using the statistical control chart-methods of Walter A. Shewhart long familiar to the SQC community. Control chart results are presented for. various measurement processes in five facilities at Langley Research Center. The processes include test section calibration, force and moment measurements with a balance, and instrument calibration.

  5. 40 CFR 51.359 - Quality control.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 2 2014-07-01 2014-07-01 false Quality control. 51.359 Section 51.359 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS REQUIREMENTS FOR... to assure test accuracy. Computer control of quality assurance checks and quality control charts...

  6. Quality of surgical randomized controlled trials for acute cholecystitis: assessment based on CONSORT and additional check items.

    PubMed

    Shikata, Satoru; Nakayama, Takeo; Yamagishi, Hisakazu

    2008-01-01

    In this study, we conducted a limited survey of reports of surgical randomized controlled trials, using the consolidated standards of reporting trials (CONSORT) statement and additional check items to clarify problems in the evaluation of surgical reports. A total of 13 randomized trials were selected from two latest review articles on biliary surgery. Each randomized trial was evaluated according to 28 quality measures that comprised items from the CONSORT statement plus additional items. Analysis focused on relationships between the quality of each study and the estimated effect gap ("pooled estimate in meta-analysis" -- "estimated effect of each study"). No definite relationships were found between individual study quality and the estimated effect gap. The following items could have been described but were not provided in almost all the surgical RCT reports: "clearly defined outcomes"; "details of randomization"; "participant flow charts"; "intention-to-treat analysis"; "ancillary analyses"; and "financial conflicts of interest". The item, "participation of a trial methodologist in the study" was not found in any of the reports. Although the quality of reporting trials is not always related to a biased estimation of treatment effect, the items used for quality measures must be described to enable readers to evaluate the quality and applicability of the reporting. Further development of an assessment tool is needed for items specific to surgical randomized controlled trials.

  7. Preliminary Retrospective Analysis of Daily Tomotherapy Output Constancy Checks Using Statistical Process Control.

    PubMed

    Mezzenga, Emilio; D'Errico, Vincenzo; Sarnelli, Anna; Strigari, Lidia; Menghi, Enrico; Marcocci, Francesco; Bianchini, David; Benassi, Marcello

    2016-01-01

    The purpose of this study was to retrospectively evaluate the results from a Helical TomoTherapy Hi-Art treatment system relating to quality controls based on daily static and dynamic output checks using statistical process control methods. Individual value X-charts, exponentially weighted moving average charts, and process capability and acceptability indices were used to monitor the treatment system performance. Daily output values measured from January 2014 to January 2015 were considered. The results obtained showed that, although the process was in control, there was an out-of-control situation in the principal maintenance intervention for the treatment system. In particular, process capability indices showed a decreasing percentage of points in control which was, however, acceptable according to AAPM TG148 guidelines. Our findings underline the importance of restricting the acceptable range of daily output checks and suggest a future line of investigation for a detailed process control of daily output checks for the Helical TomoTherapy Hi-Art treatment system.

  8. Quality Control of Meteorological Observations

    NASA Technical Reports Server (NTRS)

    Collins, William; Dee, Dick; Rukhovets, Leonid

    1999-01-01

    For the first time, a problem of the meteorological observation quality control (QC) was formulated by L.S. Gandin at the Main Geophysical Observatory in the 70's. Later in 1988 L.S. Gandin began adapting his ideas in complex quality control (CQC) to the operational environment at the National Centers for Environmental Prediction. The CQC was first applied by L.S.Gandin and his colleagues to detection and correction of errors in rawinsonde heights and temperatures using a complex of hydrostatic residuals.Later, a full complex of residuals, vertical and horizontal optimal interpolations and baseline checks were added for the checking and correction of a wide range of meteorological variables. some other of Gandin's ideas were applied and substantially developed at other meteorological centers. A new statistical QC was recently implemented in the Goddard Data Assimilation System. The central component of any quality control is a buddy check which is a test of individual suspect observations against available nearby non-suspect observations. A novel feature of this test is that the error variances which are used for QC decision are re-estimated on-line. As a result, the allowed tolerances for suspect observations can depend on local atmospheric conditions. The system is then better able to accept extreme values observed in deep cyclones, jet streams and so on. The basic statements of this adaptive buddy check are described. Some results of the on-line QC including moisture QC are presented.

  9. Helical tomotherapy quality assurance with ArcCHECK

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chapman, David; Barnett, Rob; Yartsev, Slav, E-mail: slav.yartsev@lhsc.on.ca

    2014-07-01

    To design a quality assurance (QA) procedure for helical tomotherapy that measures multiple beam parameters with 1 delivery and uses a rotating gantry to simulate treatment conditions. The customized QA procedure was preprogrammed on the tomotherapy operator station. The dosimetry measurements were performed using an ArcCHECK diode array and an A1SL ion chamber inserted in the central holder. The ArcCHECK was positioned 10 cm above the isocenter so that the 21-cm diameter detector array could measure the 40-cm wide tomotherapy beam. During the implementation of the new QA procedure, separate comparative measurements were made using ion chambers in both liquidmore » and solid water, the tomotherapy onboard detector array, and a MapCHECK diode array for a period of 10 weeks. There was good agreement (within 1.3%) for the beam output and cone ratio obtained with the new procedure and the routine QA measurements. The measured beam energy was comparable (0.3%) to solid water measurement during the 10-week evaluation period, excluding 2 of the 10 measurements with unusually high background. The symmetry reading was similarly compromised for those 2 weeks, and on the other weeks, it deviated from the solid water reading by ∼2.5%. The ArcCHECK phantom presents a suitable alternative for performing helical tomotherapy QA, provided the background is collected properly. The proposed weekly procedure using ArcCHECK and water phantom makes the QA process more efficient.« less

  10. Delivery quality assurance with ArcCHECK

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neilson, Christopher; Klein, Michael; Barnett, Rob

    2013-04-01

    Radiation therapy requires delivery quality assurance (DQA) to ensure that treatment is accurate and closely follows the plan. We report our experience with the ArcCHECK phantom and investigate its potential optimization for the DQA process. One-hundred seventy DQA plans from 84 patients were studied. Plans were classified into 2 groups: those with the target situated on the diodes of the ArcCHECK (D plans) and those with the target situated at the center (C plans). Gamma pass rates for 8 target sites were examined. The parameters used to analyze the data included 3%/3 mm with the Van Dyk percent difference criteriamore » (VD) on, 3%/3 mm with the VD off, 2%/2 mm with the VD on, and x/3 mm with the VD on and the percentage dosimetric agreement “x” for diode plans adjusted. D plans typically displayed maximum planned dose (MPD) on the cylindrical surface containing ArcCHECK diodes than center plans, resulting in inflated gamma pass rates. When this was taken into account by adjusting the percentage dosimetric agreement, C plans outperformed D plans by an average of 3.5%. ArcCHECK can streamline the DQA process, consuming less time and resources than radiographic films. It is unnecessary to generate 2 DQA plans for each patient; a single center plan will suffice. Six of 8 target sites consistently displayed pass rates well within our acceptance criteria; the lesser performance of head and neck and spinal sites can be attributed to marginally lower doses and increased high gradient of plans.« less

  11. Helical tomotherapy quality assurance with ArcCHECK.

    PubMed

    Chapman, David; Barnett, Rob; Yartsev, Slav

    2014-01-01

    To design a quality assurance (QA) procedure for helical tomotherapy that measures multiple beam parameters with 1 delivery and uses a rotating gantry to simulate treatment conditions. The customized QA procedure was preprogrammed on the tomotherapy operator station. The dosimetry measurements were performed using an ArcCHECK diode array and an A1SL ion chamber inserted in the central holder. The ArcCHECK was positioned 10cm above the isocenter so that the 21-cm diameter detector array could measure the 40-cm wide tomotherapy beam. During the implementation of the new QA procedure, separate comparative measurements were made using ion chambers in both liquid and solid water, the tomotherapy onboard detector array, and a MapCHECK diode array for a period of 10 weeks. There was good agreement (within 1.3%) for the beam output and cone ratio obtained with the new procedure and the routine QA measurements. The measured beam energy was comparable (0.3%) to solid water measurement during the 10-week evaluation period, excluding 2 of the 10 measurements with unusually high background. The symmetry reading was similarly compromised for those 2 weeks, and on the other weeks, it deviated from the solid water reading by ~2.5%. The ArcCHECK phantom presents a suitable alternative for performing helical tomotherapy QA, provided the background is collected properly. The proposed weekly procedure using ArcCHECK and water phantom makes the QA process more efficient. Copyright © 2014 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  12. [Quality control in herbal supplements].

    PubMed

    Oelker, Luisa

    2005-01-01

    Quality and safety of food and herbal supplements are the result of a whole of different elements as good manufacturing practice and process control. The process control must be active and able to individuate and correct all possible hazards. The main and most utilized instrument is the hazard analysis critical control point (HACCP) system the correct application of which can guarantee the safety of the product. Herbal supplements need, in addition to standard quality control, a set of checks to assure the harmlessness and safety of the plants used.

  13. Design of experiments enhanced statistical process control for wind tunnel check standard testing

    NASA Astrophysics Data System (ADS)

    Phillips, Ben D.

    The current wind tunnel check standard testing program at NASA Langley Research Center is focused on increasing data quality, uncertainty quantification and overall control and improvement of wind tunnel measurement processes. The statistical process control (SPC) methodology employed in the check standard testing program allows for the tracking of variations in measurements over time as well as an overall assessment of facility health. While the SPC approach can and does provide researchers with valuable information, it has certain limitations in the areas of process improvement and uncertainty quantification. It is thought by utilizing design of experiments methodology in conjunction with the current SPC practices that one can efficiently and more robustly characterize uncertainties and develop enhanced process improvement procedures. In this research, methodologies were developed to generate regression models for wind tunnel calibration coefficients, balance force coefficients and wind tunnel flow angularities. The coefficients of these regression models were then tracked in statistical process control charts, giving a higher level of understanding of the processes. The methodology outlined is sufficiently generic such that this research can be applicable to any wind tunnel check standard testing program.

  14. Take the Reins on Model Quality with ModelCHECK and Gatekeeper

    NASA Technical Reports Server (NTRS)

    Jones, Corey

    2012-01-01

    Model quality and consistency has been an issue for us due to the diverse experience level and imaginative modeling techniques of our users. Fortunately, setting up ModelCHECK and Gatekeeper to enforce our best practices has helped greatly, but it wasn't easy. There were many challenges associated with setting up ModelCHECK and Gatekeeper including: limited documentation, restrictions within ModelCHECK, and resistance from end users. However, we consider ours a success story. In this presentation we will describe how we overcame these obstacles and present some of the details of how we configured them to work for us.

  15. Austrian Daily Climate Data Rescue and Quality Control

    NASA Astrophysics Data System (ADS)

    Jurkovic, A.; Lipa, W.; Adler, S.; Albenberger, J.; Lechner, W.; Swietli, R.; Vossberg, I.; Zehetner, S.

    2010-09-01

    Checked climate datasets are a "conditio sine qua non" for all projects that are relevant for environment and climate. In the framework of climate change studies and analysis it is essential to work with quality controlled and trustful data. Furthermore these datasets are used as input for various simulation models. In regard to investigations of extreme events, like strong precipitation periods, drought periods and similar ones we need climate data in high temporal resolution (at least in daily resolution). Because of the historical background - during Second World War the majority of our climate sheets were sent to Berlin, where the historical sheets were destroyed by a bomb attack and so important information got lost - only several climate sheets, mostly duplicates, before 1939 are available and stored in our climate data archive. In 1970 the Central Institute for Meteorology and Geodynamics in Vienna started a first attempt to digitize climate data by means of punch cards. With the introduction of a routinely climate data quality control in 1984 we can speak of high-class-checked daily data (finally checked data, quality flag 6). Our group is working on the processing of digitization and quality control of the historical data for the period 1872 to 1983 for 18 years. Since 2007 it was possible to intensify the work (processes) in the framework of an internal project, namely Austrian Climate Data Rescue and Quality Control. The aim of this initiative was - and still is - to supply daily data in an outstanding good and uniform quality. So this project is a kind of pre-project for all scientific projects which are working with daily data. In addition to routine quality checks (that are running since 1984) using the commercial Bull Software we are testing our data with additional open source software, namely ProClim.db. By the use of this spatial and statistical test procedure, the elements air temperature and precipitation - for several sites in Carinthia - could

  16. Quality Assurance and Quality Control, Part 2.

    PubMed

    Akers, Michael J

    2015-01-01

    The tragedy surrounding the New England Compounding Center and contaminated steroid syringe preparations clearly points out what can happen if quality-assurance and quality-control procedures are not strictly practiced in the compounding of sterile preparations. This article is part 2 of a two-part article on requirements to comply with United States Pharmacopeia general chapters <797> and <1163> with respect to quality assurance of compounded sterile preparations. Part 1 covered documentation requirements, inspection procedures, compounding accuracy checks, and part of a discussion on bacterial endotoxin testing. Part 2 covers sterility testing, the completion from part 1 on bacterial endotoxin testing, a brief dicussion of United States Pharmacopeia <1163>, and advances in pharmaceutical quality systems.

  17. Impact of dose calibrators quality control programme in Argentina

    NASA Astrophysics Data System (ADS)

    Furnari, J. C.; de Cabrejas, M. L.; del C. Rotta, M.; Iglicki, F. A.; Milá, M. I.; Magnavacca, C.; Dima, J. C.; Rodríguez Pasqués, R. H.

    1992-02-01

    The national Quality Control (QC) programme for radionuclide calibrators started 12 years ago. Accuracy and the implementation of a QC programme were evaluated over all these years at 95 nuclear medicine laboratories where dose calibrators were in use. During all that time, the Metrology Group of CNEA has distributed 137Cs sealed sources to check stability and has been performing periodic "checking rounds" and postal surveys using unknown samples (external quality control). An account of the results of both methods is presented. At present, more of 65% of the dose calibrators measure activities with an error less than 10%.

  18. [Quality control of laser imagers].

    PubMed

    Winkelbauer, F; Ammann, M; Gerstner, N; Imhof, H

    1992-11-01

    Multiformat imagers based on laser systems are used for documentation in an increasing number of investigations. The specific problems of quality control are explained and the persistence of film processing in these imager systems of different configuration with (Machine 1: 3M-Laser-Imager-Plus M952 with connected 3M Film-Processor, 3M-Film IRB, X-Rax Chemical Mixer 3M-XPM, 3M-Developer and Fixer) or without (Machine 2: 3M-Laser-Imager-Plus M952 with separate DuPont-Cronex Film-processor, Kodak IR-Film, Kodak Automixer, Kodak-Developer and Fixer) connected film processing unit are investigated. In our checking based on DIN 6868 and ONORM S 5240 we found persistence of film processing in the equipment with directly adapted film processing unit according to DIN and ONORM. The checking of film persistence as demanded by DIN 6868 in these equipment could therefore be performed in longer periods. Systems with conventional darkroom processing comparatively show plain increased fluctuation, and hence the demanded daily control is essential to guarantee appropriate reaction and constant quality of documentation.

  19. Financial Record Checking in Surveys: Do Prompts Improve Data Quality?

    ERIC Educational Resources Information Center

    Murphy, Joe; Rosen, Jeffrey; Richards, Ashley; Riley, Sarah; Peytchev, Andy; Lindblad, Mark

    2016-01-01

    Self-reports of financial information in surveys, such as wealth, income, and assets, are particularly prone to inaccuracy. We sought to improve the quality of financial information captured in a survey conducted by phone and in person by encouraging respondents to check records when reporting on income and assets. We investigated whether…

  20. Standard Reference Specimens in Quality Control of Engineering Surfaces

    PubMed Central

    Song, J. F.; Vorburger, T. V.

    1991-01-01

    In the quality control of engineering surfaces, we aim to understand and maintain a good relationship between the manufacturing process and surface function. This is achieved by controlling the surface texture. The control process involves: 1) learning the functional parameters and their control values through controlled experiments or through a long history of production and use; 2) maintaining high accuracy and reproducibility with measurements not only of roughness calibration specimens but also of real engineering parts. In this paper, the characteristics, utilizations, and limitations of different classes of precision roughness calibration specimens are described. A measuring procedure of engineering surfaces, based on the calibration procedure of roughness specimens at NIST, is proposed. This procedure involves utilization of check specimens with waveform, wavelength, and other roughness parameters similar to functioning engineering surfaces. These check specimens would be certified under standardized reference measuring conditions, or by a reference instrument, and could be used for overall checking of the measuring procedure and for maintaining accuracy and agreement in engineering surface measurement. The concept of “surface texture design” is also suggested, which involves designing the engineering surface texture, the manufacturing process, and the quality control procedure to meet the optimal functional needs. PMID:28184115

  1. PACS quality control and automatic problem notifier

    NASA Astrophysics Data System (ADS)

    Honeyman-Buck, Janice C.; Jones, Douglas; Frost, Meryll M.; Staab, Edward V.

    1997-05-01

    One side effect of installing a clinical PACS Is that users become dependent upon the technology and in some cases it can be very difficult to revert back to a film based system if components fail. The nature of system failures range from slow deterioration of function as seen in the loss of monitor luminance through sudden catastrophic loss of the entire PACS networks. This paper describes the quality control procedures in place at the University of Florida and the automatic notification system that alerts PACS personnel when a failure has happened or is anticipated. The goal is to recover from a failure with a minimum of downtime and no data loss. Routine quality control is practiced on all aspects of PACS, from acquisition, through network routing, through display, and including archiving. Whenever possible, the system components perform self and between platform checks for active processes, file system status, errors in log files, and system uptime. When an error is detected or a exception occurs, an automatic page is sent to a pager with a diagnostic code. Documentation on each code, trouble shooting procedures, and repairs are kept on an intranet server accessible only to people involved in maintaining the PACS. In addition to the automatic paging system for error conditions, acquisition is assured by an automatic fax report sent on a daily basis to all technologists acquiring PACS images to be used as a cross check that all studies are archived prior to being removed from the acquisition systems. Daily quality control is preformed to assure that studies can be moved from each acquisition and contrast adjustment. The results of selected quality control reports will be presented. The intranet documentation server will be described with the automatic pager system. Monitor quality control reports will be described and the cost of quality control will be quantified. As PACS is accepted as a clinical tool, the same standards of quality control must be established

  2. CheckM: assessing the quality of microbial genomes recovered from isolates, single cells, and metagenomes

    PubMed Central

    Parks, Donovan H.; Imelfort, Michael; Skennerton, Connor T.; Hugenholtz, Philip; Tyson, Gene W.

    2015-01-01

    Large-scale recovery of genomes from isolates, single cells, and metagenomic data has been made possible by advances in computational methods and substantial reductions in sequencing costs. Although this increasing breadth of draft genomes is providing key information regarding the evolutionary and functional diversity of microbial life, it has become impractical to finish all available reference genomes. Making robust biological inferences from draft genomes requires accurate estimates of their completeness and contamination. Current methods for assessing genome quality are ad hoc and generally make use of a limited number of “marker” genes conserved across all bacterial or archaeal genomes. Here we introduce CheckM, an automated method for assessing the quality of a genome using a broader set of marker genes specific to the position of a genome within a reference genome tree and information about the collocation of these genes. We demonstrate the effectiveness of CheckM using synthetic data and a wide range of isolate-, single-cell-, and metagenome-derived genomes. CheckM is shown to provide accurate estimates of genome completeness and contamination and to outperform existing approaches. Using CheckM, we identify a diverse range of errors currently impacting publicly available isolate genomes and demonstrate that genomes obtained from single cells and metagenomic data vary substantially in quality. In order to facilitate the use of draft genomes, we propose an objective measure of genome quality that can be used to select genomes suitable for specific gene- and genome-centric analyses of microbial communities. PMID:25977477

  3. CheckM: assessing the quality of microbial genomes recovered from isolates, single cells, and metagenomes.

    PubMed

    Parks, Donovan H; Imelfort, Michael; Skennerton, Connor T; Hugenholtz, Philip; Tyson, Gene W

    2015-07-01

    Large-scale recovery of genomes from isolates, single cells, and metagenomic data has been made possible by advances in computational methods and substantial reductions in sequencing costs. Although this increasing breadth of draft genomes is providing key information regarding the evolutionary and functional diversity of microbial life, it has become impractical to finish all available reference genomes. Making robust biological inferences from draft genomes requires accurate estimates of their completeness and contamination. Current methods for assessing genome quality are ad hoc and generally make use of a limited number of "marker" genes conserved across all bacterial or archaeal genomes. Here we introduce CheckM, an automated method for assessing the quality of a genome using a broader set of marker genes specific to the position of a genome within a reference genome tree and information about the collocation of these genes. We demonstrate the effectiveness of CheckM using synthetic data and a wide range of isolate-, single-cell-, and metagenome-derived genomes. CheckM is shown to provide accurate estimates of genome completeness and contamination and to outperform existing approaches. Using CheckM, we identify a diverse range of errors currently impacting publicly available isolate genomes and demonstrate that genomes obtained from single cells and metagenomic data vary substantially in quality. In order to facilitate the use of draft genomes, we propose an objective measure of genome quality that can be used to select genomes suitable for specific gene- and genome-centric analyses of microbial communities. © 2015 Parks et al.; Published by Cold Spring Harbor Laboratory Press.

  4. Software Quality Control at Belle II

    NASA Astrophysics Data System (ADS)

    Ritter, M.; Kuhr, T.; Hauth, T.; Gebard, T.; Kristof, M.; Pulvermacher, C.; Belle Software Group, II

    2017-10-01

    Over the last seven years the software stack of the next generation B factory experiment Belle II has grown to over one million lines of C++ and Python code, counting only the part included in offline software releases. There are several thousand commits to the central repository by about 100 individual developers per year. To keep a coherent software stack of high quality that it can be sustained and used efficiently for data acquisition, simulation, reconstruction, and analysis over the lifetime of the Belle II experiment is a challenge. A set of tools is employed to monitor the quality of the software and provide fast feedback to the developers. They are integrated in a machinery that is controlled by a buildbot master and automates the quality checks. The tools include different compilers, cppcheck, the clang static analyzer, valgrind memcheck, doxygen, a geometry overlap checker, a check for missing or extra library links, unit tests, steering file level tests, a sophisticated high-level validation suite, and an issue tracker. The technological development infrastructure is complemented by organizational means to coordinate the development.

  5. CMM Interim Check (U)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Montano, Joshua Daniel

    2015-03-23

    Coordinate Measuring Machines (CMM) are widely used in industry, throughout the Nuclear Weapons Complex and at Los Alamos National Laboratory (LANL) to verify part conformance to design definition. Calibration cycles for CMMs at LANL are predominantly one year in length. Unfortunately, several nonconformance reports have been generated to document the discovery of a certified machine found out of tolerance during a calibration closeout. In an effort to reduce risk to product quality two solutions were proposed – shorten the calibration cycle which could be costly, or perform an interim check to monitor the machine’s performance between cycles. The CMM interimmore » check discussed makes use of Renishaw’s Machine Checking Gauge. This off-the-shelf product simulates a large sphere within a CMM’s measurement volume and allows for error estimation. Data was gathered, analyzed, and simulated from seven machines in seventeen different configurations to create statistical process control run charts for on-the-floor monitoring.« less

  6. STS-34 onboard view of iodine comparator assembly used to check water quality

    NASA Technical Reports Server (NTRS)

    1989-01-01

    STS-34 closeup view taken onboard Atlantis, Orbiter Vehicle (OV) 104, is of the iodine comparator assembly. Potable water quality is checked by comparing the water color to the color chart on the surrounding board.

  7. Body checking and eating cognitions in Brazilian outpatients with eating disorders and non psychiatric controls.

    PubMed

    Kachani, Adriana Trejger; Barroso, Lucia Pereira; Brasiliano, Silvia; Cordás, Táki Athanássios; Hochgraf, Patrícia Brunfentrinker

    2015-12-01

    Compare inadequate eating behaviors and their relationship to body checking in three groups: patients with anorexia nervosa (AN), patients with bulimia nervosa (BN) and a control group (C). Eighty three outpatients with eating disorders (ED) and 40 controls completed eating attitudes and body checking questionnaires. The overall relationship between the eating attitude and body checking was statistically significant in all three groups. The worse the eating attitude, the greater the body checking behavior. However, when we look at each group individually, the relationship was only statistically significant in the AN group (r=.354, p=0.020). The lower the desired weight and the worse the eating attitude, the more people check themselves, although in the presence of an ED the relationship between body checking and food restrictions is greater. In patients displaying the AN subgroup, body checking is also related to continued dietary control. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Statistical Quality Control of Moisture Data in GEOS DAS

    NASA Technical Reports Server (NTRS)

    Dee, D. P.; Rukhovets, L.; Todling, R.

    1999-01-01

    A new statistical quality control algorithm was recently implemented in the Goddard Earth Observing System Data Assimilation System (GEOS DAS). The final step in the algorithm consists of an adaptive buddy check that either accepts or rejects outlier observations based on a local statistical analysis of nearby data. A basic assumption in any such test is that the observed field is spatially coherent, in the sense that nearby data can be expected to confirm each other. However, the buddy check resulted in excessive rejection of moisture data, especially during the Northern Hemisphere summer. The analysis moisture variable in GEOS DAS is water vapor mixing ratio. Observational evidence shows that the distribution of mixing ratio errors is far from normal. Furthermore, spatial correlations among mixing ratio errors are highly anisotropic and difficult to identify. Both factors contribute to the poor performance of the statistical quality control algorithm. To alleviate the problem, we applied the buddy check to relative humidity data instead. This variable explicitly depends on temperature and therefore exhibits a much greater spatial coherence. As a result, reject rates of moisture data are much more reasonable and homogeneous in time and space.

  9. Quality Work, Quality Control in Technical Services.

    ERIC Educational Resources Information Center

    Horny, Karen L.

    1985-01-01

    Quality in library technical services is explored in light of changes produced by automation. Highlights include a definition of quality; new opportunities and shifting priorities; cataloging (fullness of records, heading consistency, accountability, local standards, automated checking); need for new skills (management, staff); and boons of…

  10. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR FORM QA/QC CHECKS (UA-C-2.0)

    EPA Science Inventory

    The purpose of this SOP is to outline the process of Field Quality Assurance and Quality Control checks. This procedure was followed to ensure consistent data retrieval during the Arizona NHEXAS project and the "Border" study. Keywords: custody; QA/QC; field checks.

    The Nation...

  11. Visplause: Visual Data Quality Assessment of Many Time Series Using Plausibility Checks.

    PubMed

    Arbesser, Clemens; Spechtenhauser, Florian; Muhlbacher, Thomas; Piringer, Harald

    2017-01-01

    Trends like decentralized energy production lead to an exploding number of time series from sensors and other sources that need to be assessed regarding their data quality (DQ). While the identification of DQ problems for such routinely collected data is typically based on existing automated plausibility checks, an efficient inspection and validation of check results for hundreds or thousands of time series is challenging. The main contribution of this paper is the validated design of Visplause, a system to support an efficient inspection of DQ problems for many time series. The key idea of Visplause is to utilize meta-information concerning the semantics of both the time series and the plausibility checks for structuring and summarizing results of DQ checks in a flexible way. Linked views enable users to inspect anomalies in detail and to generate hypotheses about possible causes. The design of Visplause was guided by goals derived from a comprehensive task analysis with domain experts in the energy sector. We reflect on the design process by discussing design decisions at four stages and we identify lessons learned. We also report feedback from domain experts after using Visplause for a period of one month. This feedback suggests significant efficiency gains for DQ assessment, increased confidence in the DQ, and the applicability of Visplause to summarize indicators also outside the context of DQ.

  12. Automated quality checks on repeat prescribing.

    PubMed Central

    Rogers, Jeremy E; Wroe, Christopher J; Roberts, Angus; Swallow, Angela; Stables, David; Cantrill, Judith A; Rector, Alan L

    2003-01-01

    BACKGROUND: Good clinical practice in primary care includes periodic review of repeat prescriptions. Markers of prescriptions that may need review have been described, but manually checking all repeat prescriptions against the markers would be impractical. AIM: To investigate the feasibility of computerising the application of repeat prescribing quality checks to electronic patient records in United Kingdom (UK) primary care. DESIGN OF STUDY: Software performance test against benchmark manual analysis of cross-sectional convenience sample of prescribing documentation. SETTING: Three general practices in Greater Manchester, in the north west of England, during a 4-month period in 2001. METHOD: A machine-readable drug information resource, based on the British National Formulary (BNF) as the 'gold standard' for valid drug indications, was installed in three practices. Software raised alerts for each repeat prescribed item where the electronic patient record contained no valid indication for the medication. Alerts raised by the software in two practices were analysed manually. Clinical reaction to the software was assessed by semi-structured interviews in three practices. RESULTS: There was no valid indication in the electronic medical records for 14.8% of repeat prescribed items. Sixty-two per cent of all alerts generated were incorrect. Forty-three per cent of all incorrect alerts were as a result of errors in the drug information resource, 44% to locally idiosyncratic clinical coding, 8% to the use of the BNF without adaptation as a gold standard, and 5% to the inability of the system to infer diagnoses that, although unrecorded, would be 'obvious' to a clinical reading the record. The interviewed clinicians supported the goals of the software. CONCLUSION: Using electronic records for secondary decision support purposes will benefit from (and may require) both more consistent electronic clinical data collection across multiple sites, and reconciling clinicians

  13. Algorithm design for automated transportation photo enforcement camera image and video quality diagnostic check modules

    NASA Astrophysics Data System (ADS)

    Raghavan, Ajay; Saha, Bhaskar

    2013-03-01

    Photo enforcement devices for traffic rules such as red lights, toll, stops, and speed limits are increasingly being deployed in cities and counties around the world to ensure smooth traffic flow and public safety. These are typically unattended fielded systems, and so it is important to periodically check them for potential image/video quality problems that might interfere with their intended functionality. There is interest in automating such checks to reduce the operational overhead and human error involved in manually checking large camera device fleets. Examples of problems affecting such camera devices include exposure issues, focus drifts, obstructions, misalignment, download errors, and motion blur. Furthermore, in some cases, in addition to the sub-algorithms for individual problems, one also has to carefully design the overall algorithm and logic to check for and accurately classifying these individual problems. Some of these issues can occur in tandem or have the potential to be confused for each other by automated algorithms. Examples include camera misalignment that can cause some scene elements to go out of focus for wide-area scenes or download errors that can be misinterpreted as an obstruction. Therefore, the sequence in which the sub-algorithms are utilized is also important. This paper presents an overview of these problems along with no-reference and reduced reference image and video quality solutions to detect and classify such faults.

  14. CRN5EXP: Expert system for statistical quality control

    NASA Technical Reports Server (NTRS)

    Hentea, Mariana

    1991-01-01

    The purpose of the Expert System CRN5EXP is to assist in checking the quality of the coils at two very important mills: Hot Rolling and Cold Rolling in a steel plant. The system interprets the statistical quality control charts, diagnoses and predicts the quality of the steel. Measurements of process control variables are recorded in a database and sample statistics such as the mean and the range are computed and plotted on a control chart. The chart is analyzed through patterns using the C Language Integrated Production System (CLIPS) and a forward chaining technique to reach a conclusion about the causes of defects and to take management measures for the improvement of the quality control techniques. The Expert System combines the certainty factors associated with the process control variables to predict the quality of the steel. The paper presents the approach to extract data from the database, the reason to combine certainty factors, the architecture and the use of the Expert System. However, the interpretation of control charts patterns requires the human expert's knowledge and lends to Expert Systems rules.

  15. Data Quality Control of the French Permanent Broadband Network in the RESIF Framework.

    NASA Astrophysics Data System (ADS)

    Grunberg, M.; Lambotte, S.; Engels, F.

    2014-12-01

    In the framework of the RESIF (Réseau Sismologique et géodésique Français) project, a new information system is setting up, allowing the improvement of the management and the distribution of high quality data from the different elements of RESIF. Within this information system, EOST (in Strasbourg) is in charge of collecting real-time permanent broadband seismic waveform, and performing Quality Control on these data. The real-time and validated data set are pushed to the French National Distribution Center (Isterre/Grenoble) to make them publicly available. Furthermore EOST hosts the BCSF-ReNaSS, in charge of the French metropolitan seismic bulletin. This allows to benefit from some high-end quality control based on the national and world-wide seismicity. Here we present the real-time seismic data flow from the stations of the French National Broad Band Network to EOST, and then, the data Quality Control procedures that were recently installed, including some new developments.The data Quality Control consists in applying a variety of processes to check the consistency of the whole system from the stations to the data center. This allows us to verify that instruments and data transmission are operating correctly. Moreover, time quality is critical for most of the scientific data applications. To face this challenge and check the consistency of polarities and amplitudes, we deployed several high-end processes including a noise correlation procedure to check for timing accuracy (intrumental time errors result in a time-shift of the whole cross-correlation, clearly distinct from those due to change in medium physical properties), and a systematic comparison of synthetic and real data for teleseismic earthquakes of magnitude larger than 6.5 to detect timing errors as well as polarity and amplitude problems.

  16. Data Quality Control of the French Permanent Broadband Network in the RESIF Framework

    NASA Astrophysics Data System (ADS)

    Grunberg, Marc; Lambotte, Sophie; Engels, Fabien; Dretzen, Remi; Hernandez, Alain

    2014-05-01

    In the framework of the RESIF (Réseau Sismologique et géodésique Français) project, a new information system is being setting up, allowing the improvement of the management and the distribution of high quality data from the different elements of RESIF and the associated networks. Within this information system, EOST (in Strasbourg) is in charge of collecting real-time permanent broadband seismic waveform, and performing Quality Control on these data. The real-time and validated data set are pushed to the French National Distribution Center (Isterre/Grenoble) in order to make them publicly available. Furthermore EOST hosts the BCSF-ReNaSS, in charge of the French metropolitan seismic bulletin. This allows to benefit from some high-end quality control based on the national and world-wide seismicity. Here we present first the real-time seismic data flow from the stations of the French National Broad Band Network to EOST, and then, the data Quality Control procedures that were recently installed, including some new developments. The data Quality Control consists in applying a variety of subprocesses to check the consistency of the whole system and process from the stations to the data center. This allows us to verify that instruments and data transmission are operating correctly. Moreover analysis of the ambient noise helps to characterize intrinsic seismic quality of the stations and to identify other kind of disturbances. The deployed Quality Control consist in a pipeline that starts with low-level procedures : check the real-time miniseed data file (file naming convention, data integrity), check for inconsistencies between waveform and meta-data (channel name, sample rate, etc.), compute waveform statistics (data availability, gap/overlap, mean, rms, time quality, spike). It is followed by some high-level procedures such as : power spectral density computation (PSD), STA/LTA computation to be correlated to the seismicity, phases picking and stations magnitudes

  17. Implementing Model-Check for Employee and Management Satisfaction

    NASA Technical Reports Server (NTRS)

    Jones, Corey; LaPha, Steven

    2013-01-01

    This presentation will discuss methods to which ModelCheck can be implemented to not only improve model quality, but also satisfy both employees and management through different sets of quality checks. This approach allows a standard set of modeling practices to be upheld throughout a company, with minimal interaction required by the end user. The presenter will demonstrate how to create multiple ModelCheck standards, preventing users from evading the system, and how it can improve the quality of drawings and models.

  18. [Pharmaceutical product quality control and good manufacturing practices].

    PubMed

    Hiyama, Yukio

    2010-01-01

    This report describes the roles of Good Manufacturing Practices (GMP) in pharmaceutical product quality control. There are three keys to pharmaceutical product quality control. They are specifications, thorough product characterization during development, and adherence to GMP as the ICH Q6A guideline on specifications provides the most important principles in its background section. Impacts of the revised Pharmaceutical Affairs Law (rPAL) which became effective in 2005 on product quality control are discussed. Progress of ICH discussion for Pharmaceutical Development (Q8), Quality Risk Management (Q9) and Pharmaceutical Quality System (Q10) are reviewed. In order to reconstruct GMP guidelines and GMP inspection system in the regulatory agencies under the new paradigm by rPAL and the ICH, a series of Health Science studies were conducted. For GMP guidelines, product GMP guideline, technology transfer guideline, laboratory control guideline and change control system guideline were written. For the GMP inspection system, inspection check list, inspection memo and inspection scenario were proposed also by the Health Science study groups. Because pharmaceutical products and their raw materials are manufactured and distributed internationally, collaborations with other national authorities are highly desired. In order to enhance the international collaborations, consistent establishment of GMP inspection quality system throughout Japan will be essential.

  19. SNPflow: A Lightweight Application for the Processing, Storing and Automatic Quality Checking of Genotyping Assays

    PubMed Central

    Schönherr, Sebastian; Neuner, Mathias; Forer, Lukas; Specht, Günther; Kloss-Brandstätter, Anita; Kronenberg, Florian; Coassin, Stefan

    2013-01-01

    Single nucleotide polymorphisms (SNPs) play a prominent role in modern genetics. Current genotyping technologies such as Sequenom iPLEX, ABI TaqMan and KBioscience KASPar made the genotyping of huge SNP sets in large populations straightforward and allow the generation of hundreds of thousands of genotypes even in medium sized labs. While data generation is straightforward, the subsequent data conversion, storage and quality control steps are time-consuming, error-prone and require extensive bioinformatic support. In order to ease this tedious process, we developed SNPflow. SNPflow is a lightweight, intuitive and easily deployable application, which processes genotype data from Sequenom MassARRAY (iPLEX) and ABI 7900HT (TaqMan, KASPar) systems and is extendible to other genotyping methods as well. SNPflow automatically converts the raw output files to ready-to-use genotype lists, calculates all standard quality control values such as call rate, expected and real amount of replicates, minor allele frequency, absolute number of discordant replicates, discordance rate and the p-value of the HWE test, checks the plausibility of the observed genotype frequencies by comparing them to HapMap/1000-Genomes, provides a module for the processing of SNPs, which allow sex determination for DNA quality control purposes and, finally, stores all data in a relational database. SNPflow runs on all common operating systems and comes as both stand-alone version and multi-user version for laboratory-wide use. The software, a user manual, screenshots and a screencast illustrating the main features are available at http://genepi-snpflow.i-med.ac.at. PMID:23527209

  20. On quality control procedures for solar radiation and meteorological measures, from subhourly to montly average time periods

    NASA Astrophysics Data System (ADS)

    Espinar, B.; Blanc, P.; Wald, L.; Hoyer-Klick, C.; Schroedter-Homscheidt, M.; Wanderer, T.

    2012-04-01

    Meteorological data measured by ground stations are often a key element in the development and validation of methods exploiting satellite images. These data are considered as a reference against which satellite-derived estimates are compared. Long-term radiation and meteorological measurements are available from a large number of measuring stations. However, close examination of the data often reveals a lack of quality, often for extended periods of time. This lack of quality has been the reason, in many cases, of the rejection of large amount of available data. The quality data must be checked before their use in order to guarantee the inputs for the methods used in modelling, monitoring, forecast, etc. To control their quality, data should be submitted to several conditions or tests. After this checking, data that are not flagged by any of the test is released as a plausible data. In this work, it has been performed a bibliographical research of quality control tests for the common meteorological variables (ambient temperature, relative humidity and wind speed) and for the usual solar radiometrical variables (horizontal global and diffuse components of the solar radiation and the beam normal component). The different tests have been grouped according to the variable and the average time period (sub-hourly, hourly, daily and monthly averages). The quality test may be classified as follows: • Range checks: test that verify values are within a specific range. There are two types of range checks, those based on extrema and those based on rare observations. • Step check: test aimed at detecting unrealistic jumps or stagnation in the time series. • Consistency checks: test that verify the relationship between two or more time series. The gathered quality tests are applicable for all latitudes as they have not been optimized regionally nor seasonably with the aim of being generic. They have been applied to ground measurements in several geographic locations, what

  1. Enhancement of the Automated Quality Control Procedures for the International Soil Moisture Network

    NASA Astrophysics Data System (ADS)

    Heer, Elsa; Xaver, Angelika; Dorigo, Wouter; Messner, Romina

    2017-04-01

    In-situ soil moisture observations are still trusted to be the most reliable data to validate remotely sensed soil moisture products. Thus, the quality of in-situ soil moisture observations is of high importance. The International Soil Moisture Network (ISMN; http://ismn.geo.tuwien.ac.at/) provides in-situ soil moisture data from all around the world. The data is collected from individual networks and data providers, measured by different sensors in various depths. The data sets which are delivered in different units, time zones and data formats are then transformed into homogeneous data sets. An erroneous behavior of soil moisture data is very difficult to detect, due to annual and daily changes and most significantly the high influence of precipitation and snow melting processes. Only few of the network providers have a quality assessment for their data sets. Therefore, advanced quality control procedures have been developed for the ISMN (Dorigo et al. 2013). Three categories of quality checks were introduced: exceeding boundary values, geophysical consistency checks and a spectrum based approach. The spectrum based quality control algorithms aim to detect erroneous measurements which occur within plausible geophysical ranges, e.g. a sudden drop in soil moisture caused by a sensor malfunction. By defining several conditions which have to be met by the original soil moisture time series and their first and second derivative, such error types can be detected. Since the development of these sophisticated methods many more data providers shared their data with the ISMN and new types of erroneous measurements were identified. Thus, an enhancement of the automated quality control procedures became necessary. In the present work, we introduce enhancements of the existing quality control algorithms. Additionally, six completely new quality checks have been developed, e.g. detection of suspicious values before or after NAN-values, constant values and values that lie in a

  2. An analysis of the ArcCHECK-MR diode array's performance for ViewRay quality assurance.

    PubMed

    Ellefson, Steven T; Culberson, Wesley S; Bednarz, Bryan P; DeWerd, Larry A; Bayouth, John E

    2017-07-01

    The ArcCHECK-MR diode array utilizes a correction system with a virtual inclinometer to correct the angular response dependencies of the diodes. However, this correction system cannot be applied to measurements on the ViewRay MR-IGRT system due to the virtual inclinometer's incompatibility with the ViewRay's multiple simultaneous beams. Additionally, the ArcCHECK's current correction factors were determined without magnetic field effects taken into account. In the course of performing ViewRay IMRT quality assurance with the ArcCHECK, measurements were observed to be consistently higher than the ViewRay TPS predictions. The goals of this study were to quantify the observed discrepancies and test whether applying the current factors improves the ArcCHECK's accuracy for measurements on the ViewRay. Gamma and frequency analysis were performed on 19 ViewRay patient plans. Ion chamber measurements were performed at a subset of diode locations using a PMMA phantom with the same dimensions as the ArcCHECK. A new method for applying directionally dependent factors utilizing beam information from the ViewRay TPS was developed in order to analyze the current ArcCHECK correction factors. To test the current factors, nine ViewRay plans were altered to be delivered with only a single simultaneous beam and were measured with the ArcCHECK. The current correction factors were applied using both the new and current methods. The new method was also used to apply corrections to the original 19 ViewRay plans. It was found the ArcCHECK systematically reports doses higher than those actually delivered by the ViewRay. Application of the current correction factors by either method did not consistently improve measurement accuracy. As dose deposition and diode response have both been shown to change under the influence of a magnetic field, it can be concluded the current ArcCHECK correction factors are invalid and/or inadequate to correct measurements on the ViewRay system. © 2017 The

  3. A rigorous approach to self-checking programming

    NASA Technical Reports Server (NTRS)

    Hua, Kien A.; Abraham, Jacob A.

    1986-01-01

    Self-checking programming is shown to be an effective concurrent error detection technique. The reliability of a self-checking program however relies on the quality of its assertion statements. A self-checking program written without formal guidelines could provide a poor coverage of the errors. A constructive technique for self-checking programming is presented. A Structured Program Design Language (SPDL) suitable for self-checking software development is defined. A set of formal rules, was also developed, that allows the transfromation of SPDL designs into self-checking designs to be done in a systematic manner.

  4. Continuous integration and quality control for scientific software

    NASA Astrophysics Data System (ADS)

    Neidhardt, A.; Ettl, M.; Brisken, W.; Dassing, R.

    2013-08-01

    Modern software has to be stable, portable, fast and reliable. This is going to be also more and more important for scientific software. But this requires a sophisticated way to inspect, check and evaluate the quality of source code with a suitable, automated infrastructure. A centralized server with a software repository and a version control system is one essential part, to manage the code basis and to control the different development versions. While each project can be compiled separately, the whole code basis can also be compiled with one central “Makefile”. This is used to create automated, nightly builds. Additionally all sources are inspected automatically with static code analysis and inspection tools, which check well-none error situations, memory and resource leaks, performance issues, or style issues. In combination with an automatic documentation generator it is possible to create the developer documentation directly from the code and the inline comments. All reports and generated information are presented as HTML page on a Web server. Because this environment increased the stability and quality of the software of the Geodetic Observatory Wettzell tremendously, it is now also available for scientific communities. One regular customer is already the developer group of the DiFX software correlator project.

  5. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR FORM QA AND QC CHECKS (UA-C-2.0)

    EPA Science Inventory

    The purpose of this SOP is to outline the process of field quality assurance and quality control checks. This procedure was followed to ensure consistent data retrieval during the Arizona NHEXAS project and the Border study. Keywords: custody; QA/QC; field checks.

    The U.S.-Mex...

  6. The Modern Measurement Technology And Checking Of Shafs Parameters

    NASA Astrophysics Data System (ADS)

    Tichá, Šárka; Botek, Jan

    2015-12-01

    This paper is focused on rationalization checking parameters of shaft in companies engaged in the production of components of electric motors, wind turbines and vacuum systems. Customers increasing constantly their requirements to ensure the overall quality of the product, i.e. the quality of machining, dimensional and shape accuracy and overall purity of the subscribed products. The aim of this paper is to introduce using modern measurement technology in controlling these components and compare the results with existing control methodology. The main objective of this rationalization is to eliminate mistakes and shortcomings of current inspection methods.

  7. A special ionisation chamber for quality control of diagnostic and mammography X ray equipment.

    PubMed

    Costa, A M; Caldas, L V E

    2003-01-01

    A quality control program for X ray equipment used for conventional radiography and mammography requires the constancy check of the beam qualities in terms of the half-value layers. In this work, a special double-faced parallel-plate ionisation chamber was developed with inner electrodes of different materials, in a tandem system. Its application will be in quality control programs of diagnostic and mammography X ray equipment for confirmation of half-value layers previously determined by the conventional method. Moreover, the chamber also may be utilised for measurements of air kerma values (and air kerma rates) in X radiation fields used for conventional radiography and mammography. The chamber was studied in relation to the characteristics of saturation, ion collection efficiency, polarity effects, leakage current, and short-term stability. The energy dependence in response of each of the two faces of the chamber was determined over the conventional radiography and mammography X ray ranges (unattenuated beams). The different energy response of the two faces of the chamber allowed the formation of a tandem system useful for the constancy check of beam qualities.

  8. Application of reiteration of Hankel singular value decomposition in quality control

    NASA Astrophysics Data System (ADS)

    Staniszewski, Michał; Skorupa, Agnieszka; Boguszewicz, Łukasz; Michalczuk, Agnieszka; Wereszczyński, Kamil; Wicher, Magdalena; Konopka, Marek; Sokół, Maria; Polański, Andrzej

    2017-07-01

    Medical centres are obliged to store past medical records, including the results of quality assurance (QA) tests of the medical equipment, which is especially useful in checking reproducibility of medical devices and procedures. Analysis of multivariate time series is an important part of quality control of NMR data. In this work we proposean anomaly detection tool based on Reiteration of Hankel Singular Value Decomposition method. The presented method was compared with external software and authors obtained comparable results.

  9. Basal Area Growth Estimators for Survivor Component: A Quality Control Application

    Treesearch

    Charles E. Thomas; Francis A. Roesch

    1990-01-01

    Several possible estimators are available for basal area growth of survivor trees, when horizontal prism (or point) plots (HPP) are remeasured. This study's comparison of three estimators not only provides a check for the estimate of basal area growth but suggests that they can provide a quality control indicator for yield procedures. An example is derived from...

  10. Applicability of refractometry for fast routine checking of hospital preparations.

    PubMed

    Hendrickx, Stijn; Verón, Aurora Monteagudo; Van Schepdael, Ann; Adams, Erwin

    2016-04-30

    Quality control of hospital pharmacy formulations is of the utmost importance to ensure constant quality and to avoid potential mistakes before administration to the patient. In this study we investigated the applicability of refractometry as a fast, inexpensive and easy-to-use quality control measurement. Refractive indices (RI) of a multitude of different hospital formulations with varying concentrations of active compound were measured. The samples consisted of a number of binary aqueous solutions (one compound in water), complex aqueous solutions (multiple compounds in water or in a constant matrix), two suspensions and one emulsion. For all these formulations, linear regression analysis was performed, quality control limits determined and accuracy and repeatability were checked. Subsequently, actual hospital pharmacy samples were analyzed to check whether they were within the specified limits. For both binary and complex aqueous formulations, repeatability was good and a linear correlation for all samples could be observed on condition that the concentration of the active compound was sufficiently high. The refractometer was not sensitive enough for solutions of folic acid and levothyroxine, which had too low a concentration of active compound. Due to lack of homogeneity and light scattering, emulsions and suspensions do not seem suitable for quality control by refractometry. A mathematical equation was generated to predict the refractive index of an aqueous solution containing clonidine HCl as active compound. Values calculated from the equation were compared with measured values and deviations of all samples were found to be lower than 1.3%. In order to use refractometry in a hospital pharmacy for quality control of multicomponent samples, additional intermediate measurements would be required, to overcome the fact that refractometry is not compound specific. In conclusion, we found that refractometry could potentially be useful for daily, fast quality

  11. Evaluation of non-destructive technologies for construction quality control of HMA and PCC pavements in Louisiana : [research project capsule].

    DOT National Transportation Integrated Search

    2009-07-01

    Current roadway quality control and quality acceptance (QC/QA) procedures : for Louisiana include coring for thickness, density, and air void checks in hot : mix asphalt (HMA) pavements and thickness and compressive strength for : Portland cement con...

  12. Affect adjective check list assessment of mood variations in air traffic controllers.

    DOT National Transportation Integrated Search

    1971-04-01

    Three groups of subjects completed Composite Mood Adjective Check Lists (CMACL) before and after selected shifts at two air traffic control (ATC) facilities as part of a multi-discipline study of stress in ATC work. : At one facility, a high traffic ...

  13. Quality Control System using Simple Implementation of Seven Tools for Batik Textile Manufacturing

    NASA Astrophysics Data System (ADS)

    Ragil Suryoputro, Muhammad; Sugarindra, Muchamad; Erfaisalsyah, Hendy

    2017-06-01

    In order to produce better products and mitigate defect in products, every company must implement a quality control system. Company will find means to implement a quality control system that is capable and reliable. One of the methods is using the simple implementation of the seven tools in quality control defects. The case studied in this research was the level of disability xyz grey fabric on a shuttle loom 2 on the Batik manufacturing company. The seven tools that include: flowchart, check sheet, histogram, scatter diagram combined with control charts, Pareto diagrams and fishbone diagrams (causal diagram). Check sheet results obtained types of defects in the grey fabric was woven xyz is warp, double warp, the warp break, double warp, empty warp, warp tenuous, ugly edges, thick warp, and rust. Based on the analysis of control chart indicates that the process is out of control. This can be seen in the graph control where there is still a lot of outlier data. Based on a scatter diagram shows a positive correlation between the percentage of disability and the number of production. Based on Pareto diagram, repair needs priority is for the dominant type of defect is warp (44%) and based on double warp value histogram is also the highest with a value of 23635.11 m. In addition, based on the analysis of the factors causing defect by fishbone diagram double warp or other types of defects originating from the materials, methods, machines, measurements, man and environment. Thus the company can take to minimize the prevention and repair of defects and improve product quality.

  14. Quality control of FWC during assembly and commissioning in SST-1 Tokamak

    NASA Astrophysics Data System (ADS)

    Patel, Hitesh; Santra, Prosenjit; Parekh, Tejas; Biswas, Prabal; Jayswal, Snehal; Chauhan, Pradeep; Paravastu, Yuvakiran; George, Siju; Semwal, Pratibha; Thankey, Prashant; Ramesh, Gattu; Prakash, Arun; Dhanani, Kalpesh; Raval, D. C.; Khan, Ziauddin; Pradhan, Subrata

    2017-04-01

    First Wall Components (FWC) of SST-1 tokamak, which are in the immediate vicinity of plasma, comprises of limiters, divertors, baffles, passive stabilizers designed to operate long duration (∼1000 s) discharges of elongated plasma. All FWC consist of copper alloy heat sink modules with SS cooling tubes brazed onto it, graphite tiles acting as armour material facing the plasma, and are mounted to the vacuum vessels with suitable Inconel support structures at inter-connected ring & port locations. The FWC are very recently assembled and commissioned successfully inside the vacuum vessel of SST-1 undergoing a rigorous quality control and checks at every stage of the assembly process. This paper will present the quality control aspects and checks of FWC from commencement of assembly procedure, namely material test reports, leak testing of high temperature baked components, assembled dimensional tolerances, leak testing of all welded joints, graphite tile tightening torques, electrical continuity and electrical isolation of passive stabilizers from vacuum vessel, baking and cooling hydraulic connections inside vacuum vessel.

  15. Nurse-Facilitated Health Checks for Persons With Severe Mental Illness: A Cluster-Randomized Controlled Trial.

    PubMed

    White, Jacquie; Lucas, Joanne; Swift, Louise; Barton, Garry R; Johnson, Harriet; Irvine, Lisa; Abotsie, Gabriel; Jones, Martin; Gray, Richard J

    2018-05-01

    This study tested the effectiveness of a nurse-delivered health check with the Health Improvement Profile (HIP), which takes approximately 1.5 hours to complete and code, for persons with severe mental illness. A single-blind, cluster-randomized controlled trial was conducted in England to test whether health checks improved the general medical well-being of persons with severe mental illness at 12-month follow-up. Sixty nurses were randomly assigned to the HIP group or the treatment-as-usual group. From their case lists, 173 patients agreed to participate. HIP group nurses completed health checks for 38 of their 90 patients (42%) at baseline and 22 (24%) at follow-up. No significant between-group differences were noted in patients' general medical well-being at follow-up. Nurses who had volunteered for a clinical trial administered health checks only to a minority of participating patients, suggesting that it may not be feasible to undertake such lengthy structured health checks in routine practice.

  16. Probabilistic Priority Message Checking Modeling Based on Controller Area Networks

    NASA Astrophysics Data System (ADS)

    Lin, Cheng-Min

    Although the probabilistic model checking tool called PRISM has been applied in many communication systems, such as wireless local area network, Bluetooth, and ZigBee, the technique is not used in a controller area network (CAN). In this paper, we use PRISM to model the mechanism of priority messages for CAN because the mechanism has allowed CAN to become the leader in serial communication for automobile and industry control. Through modeling CAN, it is easy to analyze the characteristic of CAN for further improving the security and efficiency of automobiles. The Markov chain model helps us to model the behaviour of priority messages.

  17. A New Quality Control Method base on IRMCD for Wind Profiler Observation towards Future Assimilation Application

    NASA Astrophysics Data System (ADS)

    Chen, Min; Zhang, Yu

    2017-04-01

    A wind profiler network with a total of 65 profiling radars was operated by the MOC/CMA in China until July 2015. In this study, a quality control procedure is constructed to incorporate the profiler data from the wind-profiling network into the local data assimilation and forecasting system (BJRUC). The procedure applies a blacklisting check that removes stations with gross errors and an outlier check that rejects data with large deviations from the background. Instead of the bi-weighting method, which has been commonly implemented in outlier elimination for one-dimensional scalar observations, an outlier elimination method is developed based on the iterated reweighted minimum covariance determinant (IRMCD) for multi-variate observations such as wind profiler data. A quality control experiment is separately performed for subsets containing profiler data tagged in parallel with/without rain flags at every 00UTC/12UTC from 20 June to 30 Sep 2015. From the results, we find that with the quality control, the frequency distributions of the differences between the observations and model background become more Gaussian-like and meet the requirements of a Gaussian distribution for data assimilation. Further intensive assessment for each quality control step reveals that the stations rejected by blacklisting contain poor data quality, and the IRMCD rejects outliers in a robust and physically reasonable manner.

  18. Checking the possibility of controlling fuel element by X-ray computerized tomography

    NASA Astrophysics Data System (ADS)

    Trinh, V. B.; Zhong, Y.; Osipov, S. P.; Batranin, A. V.

    2017-08-01

    The article considers the possibility of checking fuel elements by X-ray computerized tomography. The checking tasks are based on the detection of particles of active material, evaluation of the heterogeneity of the distribution of uranium salts and the detection of clusters of uranium particles. First of all, scheme of scanning improve the performance and quality of the resulting three-dimensional images of the internal structure is determined. Further, the possibility of detecting clusters of uranium particles having the size of 1 mm3 and measuring the coordinates of clusters of uranium particles in the middle layer with the accuracy of within a voxel size (for the considered experiments of about 80 μm) is experimentally proved in the main part. The problem of estimating the heterogeneity of the distribution of the active material in the middle layer and the detection of particles of active material with a nominal diameter of 0.1 mm in the “blank” is solved.

  19. MOM: A meteorological data checking expert system in CLIPS

    NASA Technical Reports Server (NTRS)

    Odonnell, Richard

    1990-01-01

    Meteorologists have long faced the problem of verifying the data they use. Experience shows that there is a sizable number of errors in the data reported by meteorological observers. This is unacceptable for computer forecast models, which depend on accurate data for accurate results. Most errors that occur in meteorological data are obvious to the meteorologist, but time constraints prevent hand-checking. For this reason, it is necessary to have a 'front end' to the computer model to ensure the accuracy of input. Various approaches to automatic data quality control have been developed by several groups. MOM is a rule-based system implemented in CLIPS and utilizing 'consistency checks' and 'range checks'. The system is generic in the sense that it knows some meteorological principles, regardless of specific station characteristics. Specific constraints kept as CLIPS facts in a separate file provide for system flexibility. Preliminary results show that the expert system has detected some inconsistencies not noticed by a local expert.

  20. Evaluation of Dosimetry Check software for IMRT patient-specific quality assurance.

    PubMed

    Narayanasamy, Ganesh; Zalman, Travis; Ha, Chul S; Papanikolaou, Niko; Stathakis, Sotirios

    2015-05-08

    The purpose of this study is to evaluate the use of the Dosimetry Check system for patient-specific IMRT QA. Typical QA methods measure the dose in an array dosimeter surrounded by homogenous medium for which the treatment plan has been recomputed. With the Dosimetry Check system, fluence measurements acquired on a portal dosimeter is applied to the patient's CT scans. Instead of making dose comparisons in a plane, Dosimetry Check system produces isodose lines and dose-volume histograms based on the planning CT images. By exporting the dose distribution from the treatment planning system into the Dosimetry Check system, one is able to make a direct comparison between the calculated dose and the planned dose. The versatility of the software is evaluated with respect to the two IMRT techniques - step and shoot and volumetric arc therapy. The system analyzed measurements made using EPID, PTW seven29, and IBA MatriXX, and an intercomparison study was performed. Plans from patients previously treated at our institution with treated anatomical site on brain, head & neck, liver, lung, and prostate were analyzed using Dosimetry Check system for any anatomical site dependence. We have recommendations and possible precautions that may be necessary to ensure proper QA with the Dosimetry Check system.

  1. Check Calibration of the NASA Glenn 10- by 10-Foot Supersonic Wind Tunnel (2014 Test Entry)

    NASA Technical Reports Server (NTRS)

    Johnson, Aaron; Pastor-Barsi, Christine; Arrington, E. Allen

    2016-01-01

    A check calibration of the 10- by 10-Foot Supersonic Wind Tunnel (SWT) was conducted in May/June 2014 using an array of five supersonic wedge probes to verify the 1999 Calibration. This check calibration was necessary following a control systems upgrade and an integrated systems test (IST). This check calibration was required to verify the tunnel flow quality was unchanged by the control systems upgrade prior to the next test customer beginning their test entry. The previous check calibration of the tunnel occurred in 2007, prior to the Mars Science Laboratory test program. Secondary objectives of this test entry included the validation of the new Cobra data acquisition system (DAS) against the current Escort DAS and the creation of statistical process control (SPC) charts through the collection of series of repeated test points at certain predetermined tunnel parameters. The SPC charts secondary objective was not completed due to schedule constraints. It is hoped that this effort will be readdressed and completed in the near future.

  2. Some Inspection Methods for Quality Control and In-service Inspection of GLARE

    NASA Astrophysics Data System (ADS)

    Sinke, J.

    2003-07-01

    Quality control of materials and structures is an important issue, also for GLARE. During the manufacturing stage the processes and materials should be monitored and checked frequently in order to obtain a qualified product. During the operation of the aircraft, frequent monitoring and inspections are performed to maintain the quality at a prescribed level. Therefore, in-service inspection methods are applied, and when necessary repair activities are conducted. For the quality control of the GLARE panels and components during manufacturing, the C-scan method proves to be an effective tool. For in-service inspection the Eddy Current Method is one of the suitable options. In this paper a brief overview is presented of both methods and their application on GLARE products.

  3. Slit-check dams for the control of debris flow

    NASA Astrophysics Data System (ADS)

    Armanini, Aronne; Larcher, Michele

    2017-04-01

    Debris flows are paroxysmal events that mobilize, alongside water, huge quantities of sediment in a very short time, then with both solid and liquid huge discharges, possibly exceeding the capacity of the current torrent restoration works. In this respect, the climate change forcing cannot be ignored. In the majority of urbanized areas, that are generally the most vulnerable, there is often not enough space to create channelling works able to let the volumes pass through without overflowing. The simplest, less expensive and most sustainable solution consists in reducing the peak solid discharge by creating storage areas upstream of the settlements, typically upstream of the alluvial fans, allowing for reduced works of canalization, that are compatible with the constraints imposed by the urbanization. The general idea consists in storing a part of the flowing solids during the peak of the hydrograph and releasing it in a successive phase or during minor floods. For this purpose, and in order to optimize the solid peak discharge reduction, it is necessary that properly designed open-check dams, capable of inducing a significative sedimentation of the solid discharge only when this exceeds a design-threshold value, control the deposition basins. A correct design of the check dam is crucial in order to induce the sedimentation in the right amount and at the right moment: a too early sedimentation might fill the volume before the peak, like in the case of close-check dams, while a too weak sedimentation might not use the whole available volume. In both cases, the channelling works might not be sufficient to let all the flow pass through, compromising the safety of the settlement. To avoid this inconvenience, we propose the use of slit-check dams, whose efficiency has already been proved for bed load. Check dams are often designed only on the base of the designer's experience. Besides, even today it is often believed that the filtering effect of open check dams is

  4. Quality Assurance and Control Considerations in Environmental Measurements and Monitoring

    NASA Astrophysics Data System (ADS)

    Sedlet, Jacob

    1982-06-01

    Quality assurance and quality control have become accepted as essential parts of all environmental surveillance, measurements, and monitoring programs, both nuclear and non-nuclear. The same principles and details apply to each. It is primarily the final measurement technique that differs. As the desire and need to measure smaller amounts of pollutants with greater accuracy has increased, it has been recognized that quality assurance and control programs are cost-effective in achieving the expected results. Quality assurance (QA) consists of all the actions necessary to provide confidence in the results. Quality control (QC) is a part of QA, and consists of those actions and activities that permit the control of the individual steps in the environmental program. The distinction between the two terms is not always clearly defined, but a sharp division is not necessary. The essential principle of QA and QC is a commitment to high quality results. The essential components of a QA and QC program are a complete, written procedures manual for all parts of the environmental program, the use of standard or validated procedures, participation in applicable interlaboratory comparison or QA programs, replicate analysis and measurement, training of personnel, and a means of auditing or checking that the QA and QC programs are properly conducted. These components are discussed below in some detail.

  5. Quality control in the year 2000.

    PubMed

    Schade, B

    1992-01-01

    'Just-in-time' production is a prerequisite for a company to meet the challenges of competition. Manufacturing cycles have been so successfully optimized that release time now has become a significant factor. A vision for a major quality-control (QC) contribution to profitability in this decade seems to be the just-in-time release. Benefits will go beyond cost savings for lower inventory. The earlier detection of problems will reduce rejections and scrap. In addition, problem analysis and problem-solving will be easier. To achieve just-in-time release, advanced automated systems like robots will become the workhorses in QC for high volume pharmaceutical production. The requirements for these systems are extremely high in terms of quality, reliability and ruggedness. Crucial for the success might be advances in use of microelectronics for error checks, system recording, trouble shooting, etc. as well as creative new approaches (for example the use of redundant assay systems).

  6. Quality control in the year 2000

    PubMed Central

    Schade, Bernd

    1992-01-01

    ‘Just-in-time’ production is a prerequisite for a company to meet the challenges of competition. Manufacturing cycles have been so successfully optimized that release time now has become a significant factor. A vision for a major quality-control (QC) contribution to profitability in this decade seems to be the just-in-time release. Benefits will go beyond cost savings for lower inventory. The earlier detection of problems will reduce rejections and scrap. In addition, problem analysis and problem-solving will be easier. To achieve just-in-time release, advanced automated systems like robots will become the workhorses in QC for high volume pharmaceutical production. The requirements for these systems are extremely high in terms of quality, reliability and ruggedness. Crucial for the success might be advances in use of microelectronics for error checks, system recording, trouble shooting, etc. as well as creative new approaches (for example the use of redundant assay systems). PMID:18924930

  7. The Termination of Checking and the Role of Just Right Feelings: A Study of Obsessional Checkers Compared with Anxious and Non-clinical Controls.

    PubMed

    Salkovskis, Paul M; Millar, Josie; Gregory, James D; Wahl, Karina

    2017-03-01

    Repeated checking in OCD can be understood from a cognitive perspective as the motivated need to achieve certainty about the outcome of a potentially risky action, leading to the application of Elevated Evidence Requirements (EER) and overuse of subjective criteria. Twenty-four obsessional checkers, 22 anxious controls, and 26 non-clinical controls were interviewed about and rated recent episodes where they felt (a) they needed to check and (b) checked mainly out of habit (i.e. not obsessionally). Both subjective and objective criteria were rated as significantly more important in obsessional checkers than in controls; obsessional checkers also used more criteria overall for the termination of the check, and rated more criteria as "extremely important" than the control groups. The termination of the check was rated as more effortful for obsessional checkers than for the comparison groups. Analysis of the interview data was consistent with the ratings. Feelings of "rightness" were associated with the termination of a check for obsessional checkers but not for controls. Results were consistent with the proposal that the use of "just right feelings" to terminate checking are related to EER.

  8. Enhanced invitation methods to increase uptake of NHS health checks: study protocol for a randomized controlled trial.

    PubMed

    Forster, Alice S; Burgess, Caroline; McDermott, Lisa; Wright, Alison J; Dodhia, Hiten; Conner, Mark; Miller, Jane; Rudisill, Caroline; Cornelius, Victoria; Gulliford, Martin C

    2014-08-30

    NHS Health Checks is a new program for primary prevention of heart disease, stroke, diabetes, chronic kidney disease, and vascular dementia in adults aged 40 to 74 years in England. Individuals without existing cardiovascular disease or diabetes are invited for a Health Check every 5 years. Uptake among those invited is lower than anticipated. The project is a three-arm randomized controlled trial to test the hypothesis that enhanced invitation methods, using the Question-Behaviour Effect (QBE), will increase uptake of NHS Health Checks compared with a standard invitation. Participants comprise individuals eligible for an NHS Health Check registered in two London boroughs. Participants are randomized into one of three arms. Group A receives the standard NHS Health Check invitation letter, information sheet, and reminder letter at 12 weeks for nonattenders. Group B receives a QBE questionnaire 1 week before receiving the standard invitation, information sheet, and reminder letter where appropriate. Group C is the same as Group B, but participants are offered a £5 retail voucher if they return the questionnaire. Participants are randomized in equal proportions, stratified by general practice. The primary outcome is uptake of NHS Health Checks 6 months after invitation from electronic health records. We will estimate the incremental health service cost per additional completed Health Check for trial groups B and C versus trial arm A, as well as evaluating the impact of the QBE questionnaire, and questionnaire plus voucher, on the socioeconomic inequality in uptake of Health Checks.The trial includes a nested comparison of two methods for implementing allocation, one implemented manually at general practices and the other implemented automatically through the information systems used to generate invitations for the Health Check. The research will provide evidence on whether asking individuals to complete a preliminary questionnaire, by using the QBE, is effective

  9. Microbiological water methods: quality control measures for Federal Clean Water Act and Safe Drinking Water Act regulatory compliance.

    PubMed

    Root, Patsy; Hunt, Margo; Fjeld, Karla; Kundrat, Laurie

    2014-01-01

    Quality assurance (QA) and quality control (QC) data are required in order to have confidence in the results from analytical tests and the equipment used to produce those results. Some AOAC water methods include specific QA/QC procedures, frequencies, and acceptance criteria, but these are considered to be the minimum controls needed to perform a microbiological method successfully. Some regulatory programs, such as those at Code of Federal Regulations (CFR), Title 40, Part 136.7 for chemistry methods, require additional QA/QC measures beyond those listed in the method, which can also apply to microbiological methods. Essential QA/QC measures include sterility checks, reagent specificity and sensitivity checks, assessment of each analyst's capabilities, analysis of blind check samples, and evaluation of the presence of laboratory contamination and instrument calibration and checks. The details of these procedures, their performance frequency, and expected results are set out in this report as they apply to microbiological methods. The specific regulatory requirements of CFR Title 40 Part 136.7 for the Clean Water Act, the laboratory certification requirements of CFR Title 40 Part 141 for the Safe Drinking Water Act, and the International Organization for Standardization 17025 accreditation requirements under The NELAC Institute are also discussed.

  10. Audit and internal quality control in immunohistochemistry

    PubMed Central

    Maxwell, P; McCluggage, W

    2000-01-01

    Aims—Although positive and negative controls are performed and checked in surgical pathology cases undergoing immunohistochemistry, internal quality control procedures for immunohistochemistry are not well described. This study, comprising a retrospective audit, aims to describe a method of internal quality control for immunohistochemistry. A scoring system that allows comparison between cases is described. Methods—Two positive tissue controls for each month over a three year period (1996–1998) of the 10 antibodies used most frequently were evaluated. All test cases undergoing immunohistochemistry in the months of April in this three year period were also studied. When the test case was completely negative for a given antibody, the corresponding positive tissue control from that day was examined. A marking system was devised whereby each immunohistochemical slide was assessed out of a possible score of 8 to take account of staining intensity, uniformity, specificity, background, and counterstaining. Using this scoring system, cases were classified as showing optimal (7–8), borderline (5–6), or unacceptable (0–4) staining. Results—Most positive tissue controls showed either optimal or borderline staining with the exception of neurone specific enolase (NSE), where most slides were unacceptable or borderline as a result of a combination of low intensity, poor specificity, and excessive background staining. All test cases showed either optimal or borderline staining with the exception of a single case stained for NSE, which was unacceptable. Conclusions—This retrospective audit shows that immunohistochemically stained slides can be assessed using this scoring system. With most antibodies, acceptable staining was achieved in most cases. However, there were problems with staining for NSE, which needs to be reviewed. Laboratories should use a system such as this to evaluate which antibodies regularly result in poor staining so that they can be excluded

  11. Practice nurse health checks for adults with intellectual disabilities: a cluster-design, randomised controlled trial.

    PubMed

    Cooper, Sally-Ann; Morrison, Jill; Allan, Linda M; McConnachie, Alex; Greenlaw, Nicola; Melville, Craig A; Baltzer, Marion C; McArthur, Laura A; Lammie, Claire; Martin, Gordon; Grieve, Eleanor A D; Fenwick, Elisabeth

    2014-12-01

    Adults with intellectual disabilities have substantial health inequalities and poor access to health care. We assessed whether practice nurse-delivered health checks could improve the health of adults with intellectual disabilities compared with standard care. In this cluster-design, single-blind, randomised controlled trial, we included general practices in Scotland, UK. From June to December, 2011, we randomly assigned (1:1) these general practices to either health checks plus standard care (health-checks group), or standard care only (control group), and we recruited the patients from these practices. Randomisation was done with stratification by number of GPs per practice and number of registered patients with intellectual disabilities (<20 or ≥20). Two research assistants were masked to allocation, and undertook the review of 9 month medical records and interviews. Participants and carers were not masked. The intervention was one health check designed especially for people with intellectual disabilities delivered by a practice nurse. The objective was improvement in health and health care 9 months after randomisation, and the primary outcome was the incidence of newly detected health needs being met by this timepoint. Whether needs were met was established by the investigators being masked to group allocation. The analysis was by intention to treat. This trial is registered with Current Controlled Trials, number ISRCTN43324841. Between June 26 and Dec 20, 2011, we recruited 38 practices. 85 participants (from 16 practices) were randomly assigned to intervention and 67 (from 17 practices) to standard care; five of the identified practices did not supply any participants. 83 intervention and 66 standard care participants completed the trial. More newly detected health needs were met in the intervention group than in the control standard care group (median 1 [range 0-8], 76·4% met [SD 36·5] vs 2 [0-11], 72·6% met [35·4]; odds ratio [OR] 1·73 [95% CI 0·93

  12. 31 CFR 240.3 - Electronic checks and substitute checks.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 31 Money and Finance:Treasury 2 2011-07-01 2011-07-01 false Electronic checks and substitute... OF CHECKS DRAWN ON THE UNITED STATES TREASURY General Provisions § 240.3 Electronic checks and substitute checks. (a) Legal equivalence of electronic checks. An electronic check for which a presenting...

  13. 31 CFR 240.3 - Electronic checks and substitute checks.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 31 Money and Finance:Treasury 2 2012-07-01 2012-07-01 false Electronic checks and substitute... OF CHECKS DRAWN ON THE UNITED STATES TREASURY General Provisions § 240.3 Electronic checks and substitute checks. (a) Legal equivalence of electronic checks. An electronic check for which a presenting...

  14. 31 CFR 240.3 - Electronic checks and substitute checks.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Electronic checks and substitute... OF CHECKS DRAWN ON THE UNITED STATES TREASURY General Provisions § 240.3 Electronic checks and substitute checks. (a) Legal equivalence of electronic checks. An electronic check for which a presenting...

  15. Software tool for physics chart checks.

    PubMed

    Li, H Harold; Wu, Yu; Yang, Deshan; Mutic, Sasa

    2014-01-01

    Physics chart check has long been a central quality assurance (QC) measure in radiation oncology. The purpose of this work is to describe a software tool that aims to accomplish simplification, standardization, automation, and forced functions in the process. Nationally recognized guidelines, including American College of Radiology and American Society for Radiation Oncology guidelines and technical standards, and the American Association of Physicists in Medicine Task Group reports were identified, studied, and summarized. Meanwhile, the reported events related to physics chart check service were analyzed using an event reporting and learning system. A number of shortfalls in the chart check process were identified. To address these problems, a software tool was designed and developed under Microsoft. Net in C# to hardwire as many components as possible at each stage of the process. The software consists of the following 4 independent modules: (1) chart check management; (2) pretreatment and during treatment chart check assistant; (3) posttreatment chart check assistant; and (4) quarterly peer-review management. The users were a large group of physicists in the author's radiation oncology clinic. During over 1 year of use the tool has proven very helpful in chart checking management, communication, documentation, and maintaining consistency. The software tool presented in this work aims to assist physicists at each stage of the physics chart check process. The software tool is potentially useful for any radiation oncology clinics that are either in the process of pursuing or maintaining the American College of Radiology accreditation.

  16. 30 CFR 57.11058 - Check-in, check-out system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Check-in, check-out system. 57.11058 Section 57... Escapeways Escapeways-Underground Only § 57.11058 Check-in, check-out system. Each operator of an underground mine shall establish a check-in and check-out system which shall provide an accurate record of persons...

  17. 30 CFR 57.11058 - Check-in, check-out system.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Check-in, check-out system. 57.11058 Section 57... Escapeways Escapeways-Underground Only § 57.11058 Check-in, check-out system. Each operator of an underground mine shall establish a check-in and check-out system which shall provide an accurate record of persons...

  18. 30 CFR 57.11058 - Check-in, check-out system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Check-in, check-out system. 57.11058 Section 57... Escapeways Escapeways-Underground Only § 57.11058 Check-in, check-out system. Each operator of an underground mine shall establish a check-in and check-out system which shall provide an accurate record of persons...

  19. 30 CFR 57.11058 - Check-in, check-out system.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Check-in, check-out system. 57.11058 Section 57... Escapeways Escapeways-Underground Only § 57.11058 Check-in, check-out system. Each operator of an underground mine shall establish a check-in and check-out system which shall provide an accurate record of persons...

  20. 30 CFR 57.11058 - Check-in, check-out system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Check-in, check-out system. 57.11058 Section 57... Escapeways Escapeways-Underground Only § 57.11058 Check-in, check-out system. Each operator of an underground mine shall establish a check-in and check-out system which shall provide an accurate record of persons...

  1. Amelogenin test: From forensics to quality control in clinical and biochemical genomics.

    PubMed

    Francès, F; Portolés, O; González, J I; Coltell, O; Verdú, F; Castelló, A; Corella, D

    2007-01-01

    The increasing number of samples from the biomedical genetic studies and the number of centers participating in the same involves increasing risk of mistakes in the different sample handling stages. We have evaluated the usefulness of the amelogenin test for quality control in sample identification. Amelogenin test (frequently used in forensics) was undertaken on 1224 individuals participating in a biomedical study. Concordance between referred sex in the database and amelogenin test was estimated. Additional sex-error genetic detecting systems were developed. The overall concordance rate was 99.84% (1222/1224). Two samples showed a female amelogenin test outcome, being codified as males in the database. The first, after checking sex-specific biochemical and clinical profile data was found to be due to a codification error in the database. In the second, after checking the database, no apparent error was discovered because a correct male profile was found. False negatives in amelogenin male sex determination were discarded by additional tests, and feminine sex was confirmed. A sample labeling error was revealed after a new DNA extraction. The amelogenin test is a useful quality control tool for detecting sex-identification errors in large genomic studies, and can contribute to increase its validity.

  2. Sediment traps with guiding channel and hybrid check dams improve controlled sediment retention

    NASA Astrophysics Data System (ADS)

    Schwindt, Sebastian; Franca, Mário J.; Reffo, Alessandro; Schleiss, Anton J.

    2018-03-01

    Sediment traps with partially open check dams are crucial elements for flood protection in alpine regions. The trapping of sediment is necessary when intense sediment transport occurs during floods that may endanger urban areas at downstream river reaches. In turn, the unwanted permanent trapping of sediment during small, non-hazardous floods can result in the ecological and morphological degradation of downstream reaches. This study experimentally analyses a novel concept for permeable sediment traps. For ensuring the sediment transfer up to small floods, a guiding channel implemented in the deposition area of a sediment trap was systematically studied. The bankfull discharge of the guiding channel corresponds to a dominant morphological discharge. At the downstream end of the guiding channel, a permeable barrier (check dam) triggers sediment retention and deposition. The permeable barrier consists of a bar screen for mechanical deposition control, superposed to a flow constriction for the hydraulic control. The barrier obstructs hazardous sediment transport for discharges that are higher than the bankfull discharge of the guiding channel without the risk of unwanted sediment flushing (massive self-cleaning).

  3. AutoLock: a semiautomated system for radiotherapy treatment plan quality control.

    PubMed

    Dewhurst, Joseph M; Lowe, Matthew; Hardy, Mark J; Boylan, Christopher J; Whitehurst, Philip; Rowbottom, Carl G

    2015-05-08

    A semiautomated system for radiotherapy treatment plan quality control (QC), named AutoLock, is presented. AutoLock is designed to augment treatment plan QC by automatically checking aspects of treatment plans that are well suited to computational evaluation, whilst summarizing more subjective aspects in the form of a checklist. The treatment plan must pass all automated checks and all checklist items must be acknowledged by the planner as correct before the plan is finalized. Thus AutoLock uniquely integrates automated treatment plan QC, an electronic checklist, and plan finalization. In addition to reducing the potential for the propagation of errors, the integration of AutoLock into the plan finalization workflow has improved efficiency at our center. Detailed audit data are presented, demonstrating that the treatment plan QC rejection rate fell by around a third following the clinical introduction of AutoLock.

  4. Infilling and quality checking of discharge, precipitation and temperature data using a copula based approach

    NASA Astrophysics Data System (ADS)

    Anwar, Faizan; Bárdossy, András; Seidel, Jochen

    2017-04-01

    Estimating missing values in a time series of a hydrological variable is an everyday task for a hydrologist. Existing methods such as inverse distance weighting, multivariate regression, and kriging, though simple to apply, provide no indication of the quality of the estimated value and depend mainly on the values of neighboring stations at a given step in the time series. Copulas have the advantage of representing the pure dependence structure between two or more variables (given the relationship between them is monotonic). They rid us of questions such as transforming the data before use or calculating functions that model the relationship between the considered variables. A copula-based approach is suggested to infill discharge, precipitation, and temperature data. As a first step the normal copula is used, subsequently, the necessity to use non-normal / non-symmetrical dependence is investigated. Discharge and temperature are treated as regular continuous variables and can be used without processing for infilling and quality checking. Due to the mixed distribution of precipitation values, it has to be treated differently. This is done by assigning a discrete probability to the zeros and treating the rest as a continuous distribution. Building on the work of others, along with infilling, the normal copula is also utilized to identify values in a time series that might be erroneous. This is done by treating the available value as missing, infilling it using the normal copula and checking if it lies within a confidence band (5 to 95% in our case) of the obtained conditional distribution. Hydrological data from two catchments Upper Neckar River (Germany) and Santa River (Peru) are used to demonstrate the application for datasets with different data quality. The Python code used here is also made available on GitHub. The required input is the time series of a given variable at different stations.

  5. In pursuit of quality by viable quality assurance system: the controllers' perceptions.

    PubMed

    Aziz, Anwar

    2011-01-01

    Patients, families and communities expect safe, competent and compassionate nursing care that has always been a core value of nursing. To meet these expectations, a valid and reliable quality assurance (QA) system is crucial to ensure that nurse-graduates are competent, confident and fit to practice. The QA approach is seen to be fundamental for quality improvement, it would be appropriate to consider its influence in the nursing education in Pakistan as the current situation is evident of non-existence of such a system to assure its quality. The data is drawn from a qualitative case study conducted in 2004. Among a purposive sample of 71 nurses inclusive of a group of Controllers were interviewed on one-to-one basis. Interviews were audio taped to reduce the risk of any misinterpretation and to facilitate the exact description of data as it was said. The non-directive, semi-structured and open-ended questionnaire was used to collect data. Thematic analysis of verbatim transcripts of the interviews was done. The study findings reveal a unanimous desire of the nurses to gauge quality of nurse education through efficient and effective quality assurance system. A crucial need is felt to develop a viable quality assurance system to ensure approved level of quality in nursing education to deliver the right care to the right patient at the right time, every time. The continuous quality assurance and improvement (CQAI) framework based on Deming Quality Cycle (Plan, Do, Check and Act) could facilitate appropriate designing and development of mechanism.

  6. User's Guide for ERB 7 Matrix. Volume 1: Experiment Description and Quality Control Report for Year 1

    NASA Technical Reports Server (NTRS)

    Tighe, R. J.; Shen, M. Y. H.

    1984-01-01

    The Nimbus 7 ERB MATRIX Tape is a computer program in which radiances and irradiances are converted into fluxes which are used to compute the basic scientific output parameters, emitted flux, albedo, and net radiation. They are spatially averaged and presented as time averages over one-day, six-day, and monthly periods. MATRIX data for the period November 16, 1978 through October 31, 1979 are presented. Described are the Earth Radiation Budget experiment, the Science Quality Control Report, Items checked by the MATRIX Science Quality Control Program, and Science Quality Control Data Analysis Report. Additional material from the detailed scientific quality control of the tapes which may be very useful to a user of the MATRIX tapes is included. Known errors and data problems and some suggestions on how to use the data for further climatologic and atmospheric physics studies are also discussed.

  7. Symbolic LTL Compilation for Model Checking: Extended Abstract

    NASA Technical Reports Server (NTRS)

    Rozier, Kristin Y.; Vardi, Moshe Y.

    2007-01-01

    In Linear Temporal Logic (LTL) model checking, we check LTL formulas representing desired behaviors against a formal model of the system designed to exhibit these behaviors. To accomplish this task, the LTL formulas must be translated into automata [21]. We focus on LTL compilation by investigating LTL satisfiability checking via a reduction to model checking. Having shown that symbolic LTL compilation algorithms are superior to explicit automata construction algorithms for this task [16], we concentrate here on seeking a better symbolic algorithm.We present experimental data comparing algorithmic variations such as normal forms, encoding methods, and variable ordering and examine their effects on performance metrics including processing time and scalability. Safety critical systems, such as air traffic control, life support systems, hazardous environment controls, and automotive control systems, pervade our daily lives, yet testing and simulation alone cannot adequately verify their reliability [3]. Model checking is a promising approach to formal verification for safety critical systems which involves creating a formal mathematical model of the system and translating desired safety properties into a formal specification for this model. The complement of the specification is then checked against the system model. When the model does not satisfy the specification, model-checking tools accompany this negative answer with a counterexample, which points to an inconsistency between the system and the desired behaviors and aids debugging efforts.

  8. Application Research of Quality Control Technology of Asphalt Pavement based on GPS Intelligent

    NASA Astrophysics Data System (ADS)

    Wang, Min; Gao, Bo; Shang, Fei; Wang, Tao

    2017-10-01

    Due to the difficulty of steel deck pavement asphalt layer compaction caused by the effect of the flexible supporting system (orthotropic steel deck plate), it is usually hard and difficult to control for the site compactness to reach the design goal. The intelligent compaction technology is based on GPS control technology and real-time acquisition of actual compaction tracks, and then forms a cloud maps of compaction times, which guide the roller operator to do the compaction in accordance with the design requirement to ensure the deck compaction technology and compaction quality. From the actual construction situation of actual bridge and checked data, the intelligent compaction technology is significant in guaranteeing the steel deck asphalt pavement compactness and quality stability.

  9. Managed aquifer recharge by a check dam to improve the quality of fluoride-rich groundwater: a case study from southern India.

    PubMed

    Gowrisankar, G; Jagadeshan, G; Elango, L

    2017-04-01

    In many regions around the globe, including India, degradation in the quality of groundwater is of great concern. The objective of this investigation is to determine the effect of recharge from a check dam on quality of groundwater in a region of Krishnagiri District of Tamil Nadu State, India. For this study, water samples from 15 wells were periodically obtained and analysed for major ions and fluoride concentrations. The amount of major ions present in groundwater was compared with the drinking water guideline values of the Bureau of Indian Standards. With respect to the sodium and fluoride concentrations, 38% of groundwater samples collected was not suitable for direct use as drinking water. Suitability of water for agricultural use was determined considering the electrical conductivity, sodium adsorption ratio, sodium percentage, permeability index, Wilcox and United States Salinity Laboratory diagrams. The influence of freshwater recharge from the dam is evident as the groundwater in wells nearer to the check dam was suitable for both irrigation and domestic purposes. However, the groundwater away from the dam had a high ionic composition. This study demonstrated that in other fluoride-affected areas, the concentration can be reduced by dilution with the construction of check dams as a measure of managed aquifer recharge.

  10. AutoLock: a semiautomated system for radiotherapy treatment plan quality control

    PubMed Central

    Lowe, Matthew; Hardy, Mark J.; Boylan, Christopher J.; Whitehurst, Philip; Rowbottom, Carl G.

    2015-01-01

    A semiautomated system for radiotherapy treatment plan quality control (QC), named AutoLock, is presented. AutoLock is designed to augment treatment plan QC by automatically checking aspects of treatment plans that are well suited to computational evaluation, whilst summarizing more subjective aspects in the form of a checklist. The treatment plan must pass all automated checks and all checklist items must be acknowledged by the planner as correct before the plan is finalized. Thus AutoLock uniquely integrates automated treatment plan QC, an electronic checklist, and plan finalization. In addition to reducing the potential for the propagation of errors, the integration of AutoLock into the plan finalization workflow has improved efficiency at our center. Detailed audit data are presented, demonstrating that the treatment plan QC rejection rate fell by around a third following the clinical introduction of AutoLock. PACS number: 87.55.Qr PMID:26103498

  11. Reliability of chemotherapy preparation processes: Evaluating independent double-checking and computer-assisted gravimetric control.

    PubMed

    Carrez, Laurent; Bouchoud, Lucie; Fleury-Souverain, Sandrine; Combescure, Christophe; Falaschi, Ludivine; Sadeghipour, Farshid; Bonnabry, Pascal

    2017-03-01

    Background and objectives Centralized chemotherapy preparation units have established systematic strategies to avoid errors. Our work aimed to evaluate the accuracy of manual preparations associated with different control methods. Method A simulation study in an operational setting used phenylephrine and lidocaine as markers. Each operator prepared syringes that were controlled using a different method during each of three sessions (no control, visual double-checking, and gravimetric control). Eight reconstitutions and dilutions were prepared in each session, with variable doses and volumes, using different concentrations of stock solutions. Results were analyzed according to qualitative (choice of stock solution) and quantitative criteria (accurate, <5% deviation from the target concentration; weakly accurate, 5%-10%; inaccurate, 10%-30%; wrong, >30% deviation). Results Eleven operators carried out 19 sessions. No final preparation (n = 438) contained a wrong drug. The protocol involving no control failed to detect 1 of 3 dose errors made and double-checking failed to detect 3 of 7 dose errors. The gravimetric control method detected all 5 out of 5 dose errors. The accuracy of the doses measured was equivalent across the control methods ( p = 0.63 Kruskal-Wallis). The final preparations ranged from 58% to 60% accurate, 25% to 27% weakly accurate, 14% to 17% inaccurate and 0.9% wrong. A high variability was observed between operators. Discussion Gravimetric control was the only method able to detect all dose errors, but it did not improve dose accuracy. A dose accuracy with <5% deviation cannot always be guaranteed using manual production. Automation should be considered in the future.

  12. QCScreen: a software tool for data quality control in LC-HRMS based metabolomics.

    PubMed

    Simader, Alexandra Maria; Kluger, Bernhard; Neumann, Nora Katharina Nicole; Bueschl, Christoph; Lemmens, Marc; Lirk, Gerald; Krska, Rudolf; Schuhmacher, Rainer

    2015-10-24

    Metabolomics experiments often comprise large numbers of biological samples resulting in huge amounts of data. This data needs to be inspected for plausibility before data evaluation to detect putative sources of error e.g. retention time or mass accuracy shifts. Especially in liquid chromatography-high resolution mass spectrometry (LC-HRMS) based metabolomics research, proper quality control checks (e.g. for precision, signal drifts or offsets) are crucial prerequisites to achieve reliable and comparable results within and across experimental measurement sequences. Software tools can support this process. The software tool QCScreen was developed to offer a quick and easy data quality check of LC-HRMS derived data. It allows a flexible investigation and comparison of basic quality-related parameters within user-defined target features and the possibility to automatically evaluate multiple sample types within or across different measurement sequences in a short time. It offers a user-friendly interface that allows an easy selection of processing steps and parameter settings. The generated results include a coloured overview plot of data quality across all analysed samples and targets and, in addition, detailed illustrations of the stability and precision of the chromatographic separation, the mass accuracy and the detector sensitivity. The use of QCScreen is demonstrated with experimental data from metabolomics experiments using selected standard compounds in pure solvent. The application of the software identified problematic features, samples and analytical parameters and suggested which data files or compounds required closer manual inspection. QCScreen is an open source software tool which provides a useful basis for assessing the suitability of LC-HRMS data prior to time consuming, detailed data processing and subsequent statistical analysis. It accepts the generic mzXML format and thus can be used with many different LC-HRMS platforms to process both multiple

  13. Geometric facial comparisons in speed-check photographs.

    PubMed

    Buck, Ursula; Naether, Silvio; Kreutz, Kerstin; Thali, Michael

    2011-11-01

    In many cases, it is not possible to call the motorists to account for their considerable excess in speeding, because they deny being the driver on the speed-check photograph. An anthropological comparison of facial features using a photo-to-photo comparison can be very difficult depending on the quality of the photographs. One difficulty of that analysis method is that the comparison photographs of the presumed driver are taken with a different camera or camera lens and from a different angle than for the speed-check photo. To take a comparison photograph with exactly the same camera setup is almost impossible. Therefore, only an imprecise comparison of the individual facial features is possible. The geometry and position of each facial feature, for example the distances between the eyes or the positions of the ears, etc., cannot be taken into consideration. We applied a new method using 3D laser scanning, optical surface digitalization, and photogrammetric calculation of the speed-check photo, which enables a geometric comparison. Thus, the influence of the focal length and the distortion of the objective lens are eliminated and the precise position and the viewing direction of the speed-check camera are calculated. Even in cases of low-quality images or when the face of the driver is partly hidden, good results are delivered using this method. This new method, Geometric Comparison, is evaluated and validated in a prepared study which is described in this article.

  14. Pre-use anesthesia machine check; certified anesthesia technician based quality improvement audit.

    PubMed

    Al Suhaibani, Mazen; Al Malki, Assaf; Al Dosary, Saad; Al Barmawi, Hanan; Pogoku, Mahdhav

    2014-01-01

    Quality assurance of providing a work ready machine in multiple theatre operating rooms in a tertiary modern medical center in Riyadh. The aim of the following study is to keep high quality environment for workers and patients in surgical operating rooms. Technicians based audit by using key performance indicators to assure inspection, passing test of machine worthiness for use daily and in between cases and in case of unexpected failure to provide quick replacement by ready to use another anesthetic machine. The anesthetic machines in all operating rooms are daily and continuously inspected and passed as ready by technicians and verified by anesthesiologist consultant or assistant consultant. The daily records of each machines were collected then inspected for data analysis by quality improvement committee department for descriptive analysis and report the degree of staff compliance to daily inspection as "met" items. Replaced machine during use and overall compliance. Distractive statistic using Microsoft Excel 2003 tables and graphs of sums and percentages of item studied in this audit. Audit obtained highest compliance percentage and low rate of replacement of machine which indicate unexpected machine state of use and quick machine switch. The authors are able to conclude that following regular inspection and running self-check recommended by the manufacturers can contribute to abort any possibility of hazard of anesthesia machine failure during operation. Furthermore in case of unexpected reason to replace the anesthesia machine in quick maneuver contributes to high assured operative utilization of man machine inter-phase in modern surgical operating rooms.

  15. Verifying Multi-Agent Systems via Unbounded Model Checking

    NASA Technical Reports Server (NTRS)

    Kacprzak, M.; Lomuscio, A.; Lasica, T.; Penczek, W.; Szreter, M.

    2004-01-01

    We present an approach to the problem of verification of epistemic properties in multi-agent systems by means of symbolic model checking. In particular, it is shown how to extend the technique of unbounded model checking from a purely temporal setting to a temporal-epistemic one. In order to achieve this, we base our discussion on interpreted systems semantics, a popular semantics used in multi-agent systems literature. We give details of the technique and show how it can be applied to the well known train, gate and controller problem. Keywords: model checking, unbounded model checking, multi-agent systems

  16. Check & Connect: The Importance of Relationships for Promoting Engagement with School

    ERIC Educational Resources Information Center

    Anderson, Amy R.; Christenson, Sandra L.; Sinclair, Mary F.; Lehr, Camilla A.

    2004-01-01

    The purpose of this study was to examine whether the closeness and quality of relationships between intervention staff and students involved in the Check & Connect program were associated with improved student engagement in school. Participants included 80 elementary and middle school students referred to the Check & Connect program for poor…

  17. 10 CFR 34.75 - Records of alarm system and entrance control checks at permanent radiographic installations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Records of alarm system and entrance control checks at permanent radiographic installations. 34.75 Section 34.75 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Recordkeeping...

  18. 10 CFR 34.75 - Records of alarm system and entrance control checks at permanent radiographic installations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Records of alarm system and entrance control checks at permanent radiographic installations. 34.75 Section 34.75 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Recordkeeping...

  19. 10 CFR 34.75 - Records of alarm system and entrance control checks at permanent radiographic installations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Records of alarm system and entrance control checks at permanent radiographic installations. 34.75 Section 34.75 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Recordkeeping...

  20. 10 CFR 34.75 - Records of alarm system and entrance control checks at permanent radiographic installations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Records of alarm system and entrance control checks at permanent radiographic installations. 34.75 Section 34.75 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Recordkeeping...

  1. 10 CFR 34.75 - Records of alarm system and entrance control checks at permanent radiographic installations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Records of alarm system and entrance control checks at permanent radiographic installations. 34.75 Section 34.75 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Recordkeeping...

  2. Improving NGDC Track-line Data Quality Control

    NASA Astrophysics Data System (ADS)

    Chandler, M. T.; Wessel, P.

    2004-12-01

    Ship-board gravity, magnetic and bathymetry data archived at the National Geophysical Data Center (NGDC) represent decades of seagoing research, containing over 4,500 cruises. Cruise data remain relevent despite the prominence of satellite altimetry-derived global grids because many geologic processes remain resolvable by oceanographic research alone. Due to the tremendous investment put forth by scientists and taxpayers to compile this vast archive and the significant errors found within it, additional quality assessment and corrections are warranted. These can best be accomplished by adding to existing quality control measures at NGDC. We are currently developing open source software to provide additional quality control. Along with NGDC's current sanity checking, new data at NGDC will also be subjected to an along-track ``sniffer'' which will detect and flag suspicious data for later graphical inspection using a visual editor. If new data pass these tests, they will undergo further scrutinization using a crossover error (COE) calculator which will compare new data values to existing values at points of intersection within the archive. Data passing these tests will be deemed ``quality data`` and suitable for permanent addition to the archive, while data that fail will be returned to the source institution for correction. Crossover errors will be stored and an online COE database will be available. The COE database will allow users to apply corrections to the NGDC track-line database to produce corrected data files. At no time will the archived data itself be modified. An attempt will also be made to reduce navigational errors for pre-GPS navigated cruises. Upon completion these programs will be used to explore and model systematic errors within the archive, generate correction tables for all cruises, and to quantify the error budget in marine geophysical observations. Software will be released and these procedures will be implemented in cooperation with NGDC

  3. MRO Sequence Checking Tool

    NASA Technical Reports Server (NTRS)

    Fisher, Forest; Gladden, Roy; Khanampornpan, Teerapat

    2008-01-01

    The MRO Sequence Checking Tool program, mro_check, automates significant portions of the MRO (Mars Reconnaissance Orbiter) sequence checking procedure. Though MRO has similar checks to the ODY s (Mars Odyssey) Mega Check tool, the checks needed for MRO are unique to the MRO spacecraft. The MRO sequence checking tool automates the majority of the sequence validation procedure and check lists that are used to validate the sequences generated by MRO MPST (mission planning and sequencing team). The tool performs more than 50 different checks on the sequence. The automation varies from summarizing data about the sequence needed for visual verification of the sequence, to performing automated checks on the sequence and providing a report for each step. To allow for the addition of new checks as needed, this tool is built in a modular fashion.

  4. The Effects of Check-In, Check-Up, Check-Out for Students with Moderate Intellectual Disability during On- and Off-Site Vocational Training

    ERIC Educational Resources Information Center

    Boden, Lauren J.; Jolivette, Kristine; Alberto, Paul A.

    2018-01-01

    Check-in/check-out is a secondary-tier intervention within the positive behavior interventions and supports framework. Check-in/check-out pairs the use of an adult mentor with a daily progress report to help students meet individualized behavioral goals. This study adds to the research base by examining the effects of check-in, check-up, check-out…

  5. The Long-Term Effectiveness of the Family Check-up on Peer Preference: Parent-Child Interaction and Child Effortful Control as Sequential Mediators.

    PubMed

    Chang, Hyein; Shaw, Daniel S; Shelleby, Elizabeth C; Dishion, Thomas J; Wilson, Melvin N

    2017-05-01

    We examined the longitudinal effects of the Family Check-Up (FCU) intervention beginning in toddlerhood on children's peer preference at school-age. Specifically, a sequential mediational model was proposed in which the FCU was hypothesized to promote peer preference (i.e., higher acceptance and lower rejection by peers) in middle childhood through its positive effects on parent-child interaction and child effortful control in early childhood. Participants were 731 low-income families (49 % female). Qualities of parent-child interaction were observed during structured activities at 2 to 5 years, child effortful control was assessed using behavioral tasks at 5 years, and peer acceptance and rejection were rated by teachers at 7.5 to 10.5 years. Results indicated that the FCU indirectly predicted peer preference by sequentially improving parent-child interaction and child effortful control. The findings are discussed with respect to implications for understanding mechanisms by which early parenting-focused programs may enhance child functioning across time and context.

  6. The Long-Term Effectiveness of the Family Check-up on Peer Preference: Parent-Child Interaction and Child Effortful Control as Sequential Mediators

    PubMed Central

    Shaw, Daniel S.; Shelleby, Elizabeth C.; Dishion, Thomas J.; Wilson, Melvin N.

    2018-01-01

    We examined the longitudinal effects of the Family Check-Up (FCU) intervention beginning in toddlerhood on children’s peer preference at school-age. Specifically, a sequential mediational model was proposed in which the FCU was hypothesized to promote peer preference (i.e., higher acceptance and lower rejection by peers) in middle childhood through its positive effects on parent-child interaction and child effortful control in early childhood. Participants were 731 low-income families (49 % female). Qualities of parent-child interaction were observed during structured activities at 2 to 5 years, child effortful control was assessed using behavioral tasks at 5 years, and peer acceptance and rejection were rated by teachers at 7.5 to 10.5 years. Results indicated that the FCU indirectly predicted peer preference by sequentially improving parent-child interaction and child effortful control. The findings are discussed with respect to implications for understanding mechanisms by which early parenting-focused programs may enhance child functioning across time and context. PMID:27558394

  7. Implementation of Quality Assurance and Quality Control Measures in the National Phenology Database

    NASA Astrophysics Data System (ADS)

    Gerst, K.; Rosemartin, A.; Denny, E. G.; Marsh, L.; Barnett, L.

    2015-12-01

    The USA National Phenology Network (USA-NPN; www.usanpn.org) serves science and society by promoting a broad understanding of plant and animal phenology and the relationships among phenological patterns and environmental change. The National Phenology Database has over 5.5 million observation records for plants and animals for the period 1954-2015. These data have been used in a number of science, conservation and resource management applications, including national assessments of historical and potential future trends in phenology, regional assessments of spatio-temporal variation in organismal activity, and local monitoring for invasive species detection. Customizable data downloads are freely available, and data are accompanied by FGDC-compliant metadata, data-use and data-attribution policies, and vetted documented methodologies and protocols. The USA-NPN has implemented a number of measures to ensure both quality assurance and quality control. Here we describe the resources that have been developed so that incoming data submitted by both citizen and professional scientists are reliable; these include training materials, such as a botanical primer and species profiles. We also describe a number of automated quality control processes applied to incoming data streams to optimize data output quality. Existing and planned quality control measures for output of raw and derived data include: (1) Validation of site locations, including latitude, longitude, and elevation; (2) Flagging of records that conflict for a given date for an individual plant; (3) Flagging where species occur outside known ranges; (4) Flagging of records when phenophases occur outside of the plausible order for a species; (5) Flagging of records when intensity measures do not follow a plausible progression for a phenophase; (6) Flagging of records when a phenophase occurs outside of the plausible season, and (7) Quantification of precision and uncertainty for estimation of phenological metrics

  8. Progress on the Journey to Total Quality Management: Using the Myers-Briggs Type Indicator and the Adjective Check List in Management Development.

    ERIC Educational Resources Information Center

    Mani, Bonnie G.

    1995-01-01

    In an Internal Revenue Service office using total quality management (TQM), the management development program uses Myers Briggs Type Indicator and Adjective Check List for manager self-assessment. Because management commitment is essential to TQM, the process is a way of enhancing leadership skills and demonstrating appreciation of diversity. (SK)

  9. Quality Control Pathways for Nucleus-Encoded Eukaryotic tRNA Biosynthesis and Subcellular Trafficking

    PubMed Central

    Huang, Hsiao-Yun

    2015-01-01

    tRNAs perform an essential role in translating the genetic code. They are long-lived RNAs that are generated via numerous posttranscriptional steps. Eukaryotic cells have evolved numerous layers of quality control mechanisms to ensure that the tRNAs are appropriately structured, processed, and modified. We describe the known tRNA quality control processes that check tRNAs and correct or destroy aberrant tRNAs. These mechanisms employ two types of exonucleases, CCA end addition, tRNA nuclear aminoacylation, and tRNA subcellular traffic. We arrange these processes in order of the steps that occur from generation of precursor tRNAs by RNA polymerase (Pol) III transcription to end maturation and modification in the nucleus to splicing and additional modifications in the cytoplasm. Finally, we discuss the tRNA retrograde pathway, which allows tRNA reimport into the nucleus for degradation or repair. PMID:25848089

  10. SU-F-T-238: Analyzing the Performance of MapCHECK2 and Delta4 Quality Assurance Phantoms in IMRT and VMAT Plans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu, SH; Tsai, YC; Lan, HT

    2016-06-15

    Purpose: Intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) have been widely investigated for use in radiotherapy and found to have a highly conformal dose distribution. Delta{sup 4} is a novel cylindrical phantom consisting of 1069 p-type diodes with true treatments measured in the 3D target volume. The goal of this study was to compare the performance of a Delta{sup 4} diode array for IMRT and VMAT planning with ion chamber and MapCHECK2. Methods: Fifty-four IMRT (n=9) and VMAT (n=45) plans were imported to Philips Pinnacle Planning System 9.2 for recalculation with a solid water phantom, MapCHECK2, and themore » Delta4 phantom. To evaluate the difference between the measured and calculated dose, we used MapCHECK2 and Delta{sup 4} for a dose-map comparison and an ion chamber (PTW 31010 Semiflex 0.125 cc) for a point-dose comparison. Results: All 54 plans met the criteria of <3% difference for the point dose (at least two points) by ion chamber. The mean difference was 0.784% with a standard deviation of 1.962%. With a criteria of 3 mm/3% in a gamma analysis, the average passing rates were 96.86%±2.19% and 98.42%±1.97% for MapCHECK2 and Delta{sup 4}, respectively. The student t-test of MapCHECK2/Delta{sup 4}, ion chamber/Delta{sup 4}, and ion chamber/MapCHECK2 were 0.0008, 0.2944, and 0.0002, respectively. There was no significant difference in passing rates between MapCHECK2 and Delta{sup 4} for the IMRT plan (p = 0.25). However, a higher pass rate was observed in Delta{sup 4} (98.36%) as compared to MapCHECK2 (96.64%, p < 0.0001) for the VMAT plan. Conclusion: The Pinnacle planning system can accurately calculate doses for VMAT and IMRT plans. The Delta{sup 4} shows a similar result when compared to ion chamber and MapCHECK2, and is an efficient tool for patient-specific quality assurance, especially for rotation therapy.« less

  11. Check-In Check-Out + Social Skills: Enhancing the Effects of Check-In Check-Out for Students With Social Skill Deficits

    ERIC Educational Resources Information Center

    Ross, Scott W.; Sabey, Christian V.

    2015-01-01

    Check-In Check-Out is a Tier 2 intervention designed to reduce problem behavior and increase prosocial behavior. Although the intervention has demonstrated effects in several studies, few research efforts have considered how the intervention can be modified to support students with social skill deficits. Through a multiple baseline design across…

  12. Earth Observation Data Quality Monitoring and Control: A Case Study of STAR Central Data Repository

    NASA Astrophysics Data System (ADS)

    Han, W.; Jochum, M.

    2017-12-01

    Earth observation data quality is very important for researchers and decision makers involved in weather forecasting, severe weather warning, disaster and emergency response, environmental monitoring, etc. Monitoring and control earth observation data quality, especially accuracy, completeness, and timeliness, is very useful in data management and governance to optimize data flow, discover potential transmission issues, and better connect data providers and users. Taking a centralized near real-time satellite data repository, STAR (Center for Satellite Applications and Research of NOAA) Central Data Repository (SCDR), as an example, this paper describes how to develop new mechanism to verify data integrity, check data completeness, and monitor data latency in an operational data management system. Such quality monitoring and control of large volume satellite data help data providers and managers improve data transmission of near real-time satellite data, enhance its acquisition and management, and overcome performance and management issues to better serve research and development activities.

  13. 14 CFR 121.411 - Qualifications: Check airmen (airplane) and check airmen (simulator).

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Qualifications: Check airmen (airplane) and... § 121.411 Qualifications: Check airmen (airplane) and check airmen (simulator). Link to an amendment... airman (airplane) is a person who is qualified, and permitted, to conduct flight checks or instruction in...

  14. Inkjet 3D printed check microvalve

    NASA Astrophysics Data System (ADS)

    Walczak, Rafał; Adamski, Krzysztof; Lizanets, Danylo

    2017-04-01

    3D printing enables fast and relatively easy fabrication of various microfluidic structures including microvalves. A check microvalve is the simplest valve enabling control of the fluid flow in microchannels. Proper operation of the check valve is ensured by a movable element that tightens the valve seat during backward flow and enables free flow for forward pressure. Thus, knowledge of the mechanical properties of the movable element is crucial for optimal design and operation of the valve. In this paper, we present for the first time the results of investigations on basic mechanical properties of the building material used in multijet 3D printing. Specified mechanical properties were used in the design and fabrication of two types of check microvalve—with deflecting or hinge-fixed microflap—with 200 µm and 300 µm thickness. Results of numerical simulation and experimental data of the microflap deflection were obtained and compared. The valves were successfully 3D printed and characterised. Opening/closing characteristics of the microvalve for forward and backward pressures were determined. Thus, proper operation of the check microvalve so developed was confirmed.

  15. 14 CFR 121.411 - Qualifications: Check airmen (airplane) and check airmen (simulator).

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Qualifications: Check airmen (airplane) and... § 121.411 Qualifications: Check airmen (airplane) and check airmen (simulator). (a) For the purposes of this section and § 121.413: (1) A check airman (airplane) is a person who is qualified, and permitted...

  16. 14 CFR 121.411 - Qualifications: Check airmen (airplane) and check airmen (simulator).

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Qualifications: Check airmen (airplane) and... § 121.411 Qualifications: Check airmen (airplane) and check airmen (simulator). (a) For the purposes of this section and § 121.413: (1) A check airman (airplane) is a person who is qualified, and permitted...

  17. 14 CFR 121.411 - Qualifications: Check airmen (airplane) and check airmen (simulator).

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Qualifications: Check airmen (airplane) and... § 121.411 Qualifications: Check airmen (airplane) and check airmen (simulator). (a) For the purposes of this section and § 121.413: (1) A check airman (airplane) is a person who is qualified, and permitted...

  18. 14 CFR 121.411 - Qualifications: Check airmen (airplane) and check airmen (simulator).

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Qualifications: Check airmen (airplane) and... § 121.411 Qualifications: Check airmen (airplane) and check airmen (simulator). (a) For the purposes of this section and § 121.413: (1) A check airman (airplane) is a person who is qualified, and permitted...

  19. Logic Model Checking of Unintended Acceleration Claims in the 2005 Toyota Camry Electronic Throttle Control System

    NASA Technical Reports Server (NTRS)

    Gamble, Ed; Holzmann, Gerard

    2011-01-01

    Part of the US DOT investigation of Toyota SUA involved analysis of the throttle control software. JPL LaRS applied several techniques, including static analysis and logic model checking, to the software. A handful of logic models were built. Some weaknesses were identified; however, no cause for SUA was found. The full NASA report includes numerous other analyses

  20. The IEO Data Center Management System: Tools for quality control, analysis and access marine data

    NASA Astrophysics Data System (ADS)

    Casas, Antonia; Garcia, Maria Jesus; Nikouline, Andrei

    2010-05-01

    Since 1994 the Data Centre of the Spanish Oceanographic Institute develops system for archiving and quality control of oceanographic data. The work started in the frame of the European Marine Science & Technology Programme (MAST) when a consortium of several Mediterranean Data Centres began to work on the MEDATLAS project. Along the years, old software modules for MS DOS were rewritten, improved and migrated to Windows environment. Oceanographic data quality control includes now not only vertical profiles (mainly CTD and bottles observations) but also time series of currents and sea level observations. New powerful routines for analysis and for graphic visualization were added. Data presented originally in ASCII format were organized recently in an open source MySQL database. Nowadays, the IEO, as part of SeaDataNet Infrastructure, has designed and developed a new information system, consistent with the ISO 19115 and SeaDataNet standards, in order to manage the large and diverse marine data and information originated in Spain by different sources, and to interoperate with SeaDataNet. The system works with data stored in ASCII files (MEDATLAS, ODV) as well as data stored within the relational database. The components of the system are: 1.MEDATLAS Format and Quality Control - QCDAMAR: Quality Control of Marine Data. Main set of tools for working with data presented as text files. Includes extended quality control (searching for duplicated cruises and profiles, checking date, position, ship velocity, constant profiles, spikes, density inversion, sounding, acceptable data, impossible regional values,...) and input/output filters. - QCMareas: A set of procedures for the quality control of tide gauge data according to standard international Sea Level Observing System. These procedures include checking for unexpected anomalies in the time series, interpolation, filtering, computation of basic statistics and residuals. 2. DAMAR: A relational data base (MySql) designed to

  1. Check out the Atmospheric Science User Forum

    Atmospheric Science Data Center

    2016-11-16

    Check out the Atmospheric Science User Forum Tuesday, November 15, 2016 The ASDC would like to bring your attention to the Atmospheric Science User Forum. The purpose of this forum is to improve user service, quality, and efficiency of NASA atmospheric science data. The forum intends to provide a quick and easy way to facilitate ...

  2. Checking-up of optical graduated rules by laser interferometry

    NASA Astrophysics Data System (ADS)

    Miron, Nicolae P.; Sporea, Dan G.

    1996-05-01

    The main aspects related to the operating principle, design, and implementation of high-productivity equipment for checking-up the graduation accuracy of optical graduated rules used as a length reference in optical measuring instruments for precision machine tools are presented. The graduation error checking-up is done with a Michelson interferometer as a length transducer. The instrument operation is managed by a computer, which controls the equipment, data acquisition, and processing. The evaluation is performed for rule lengths from 100 to 3000 mm, with a checking-up error less than 2 micrometers/m. The checking-up time is about 15 min for a 1000-mm rule, with averaging over four measurements.

  3. Quality Leadership and Quality Control

    PubMed Central

    Badrick, Tony

    2003-01-01

    Different quality control rules detect different analytical errors with varying levels of efficiency depending on the type of error present, its prevalence and the number of observations. The efficiency of a rule can be gauged by inspection of a power function graph. Control rules are only part of a process and not an end in itself; just as important are the trouble-shooting systems employed when a failure occurs. 'Average of patient normals' may develop as a usual adjunct to conventional quality control serum based programmes. Acceptable error can be based on various criteria; biological variation is probably the most sensible. Once determined, acceptable error can be used as limits in quality control rule systems. A key aspect of an organisation is leadership, which links the various components of the quality system. Leadership is difficult to characterise but its key aspects include trust, setting an example, developing staff and critically setting the vision for the organisation. Organisations also have internal characteristics such as the degree of formalisation, centralisation, and complexity. Medical organisations can have internal tensions because of the dichotomy between the bureaucratic and the shadow medical structures. PMID:18568046

  4. Analysis of quality control data of eight modern radiotherapy linear accelerators: the short- and long-term behaviours of the outputs and the reproducibility of quality control measurements

    NASA Astrophysics Data System (ADS)

    Kapanen, Mika; Tenhunen, Mikko; Hämäläinen, Tuomo; Sipilä, Petri; Parkkinen, Ritva; Järvinen, Hannu

    2006-07-01

    Quality control (QC) data of radiotherapy linear accelerators, collected by Helsinki University Central Hospital between the years 2000 and 2004, were analysed. The goal was to provide information for the evaluation and elaboration of QC of accelerator outputs and to propose a method for QC data analysis. Short- and long-term drifts in outputs were quantified by fitting empirical mathematical models to the QC measurements. Normally, long-term drifts were well (<=1%) modelled by either a straight line or a single-exponential function. A drift of 2% occurred in 18 ± 12 months. The shortest drift times of only 2-3 months were observed for some new accelerators just after the commissioning but they stabilized during the first 2-3 years. The short-term reproducibility and the long-term stability of local constancy checks, carried out with a sealed plane parallel ion chamber, were also estimated by fitting empirical models to the QC measurements. The reproducibility was 0.2-0.5% depending on the positioning practice of a device. Long-term instabilities of about 0.3%/month were observed for some checking devices. The reproducibility of local absorbed dose measurements was estimated to be about 0.5%. The proposed empirical model fitting of QC data facilitates the recognition of erroneous QC measurements and abnormal output behaviour, caused by malfunctions, offering a tool to improve dose control.

  5. Principles and Practices for Quality Assurance and Quality Control

    USGS Publications Warehouse

    Jones, Berwyn E.

    1999-01-01

    Quality assurance and quality control are vital parts of highway runoff water-quality monitoring projects. To be effective, project quality assurance must address all aspects of the project, including project management responsibilities and resources, data quality objectives, sampling and analysis plans, data-collection protocols, data quality-control plans, data-assessment procedures and requirements, and project outputs. Quality control ensures that the data quality objectives are achieved as planned. The historical development and current state of the art of quality assurance and quality control concepts described in this report can be applied to evaluation of data from prior projects.

  6. Prediction Interval Development for Wind-Tunnel Balance Check-Loading

    NASA Technical Reports Server (NTRS)

    Landman, Drew; Toro, Kenneth G.; Commo, Sean A.; Lynn, Keith C.

    2014-01-01

    Results from the Facility Analysis Verification and Operational Reliability project revealed a critical gap in capability in ground-based aeronautics research applications. Without a standardized process for check-loading the wind-tunnel balance or the model system, the quality of the aerodynamic force data collected varied significantly between facilities. A prediction interval is required in order to confirm a check-loading. The prediction interval provides an expected upper and lower bound on balance load prediction at a given confidence level. A method has been developed which accounts for sources of variability due to calibration and check-load application. The prediction interval method of calculation and a case study demonstrating its use is provided. Validation of the methods is demonstrated for the case study based on the probability of capture of confirmation points.

  7. Check valve

    DOEpatents

    Upton, Hubert Allen; Garcia, Pablo

    1999-08-24

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion.

  8. Check valve

    DOEpatents

    Upton, H.A.; Garcia, P.

    1999-08-24

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion. 5 figs.

  9. [New idea of traditional Chinese medicine quality control based on "composition structure" theory].

    PubMed

    Liu, Dan; Jia, Xiaobin; Yu, Danhong

    2012-03-01

    On the road of the modern Chinese medicine developing internationally, there is a key issues that setting up a reasonable, accurate and be quantified quality evaluation system which is comply with the basic theory of Chinese medicine. Based on the overall understanding of the role of traditional Chinese medicine components, author suggested that the idea of "structural components" theory should be embedded into the system and thought the Chinese medicine play a multi-target, multi-channel pharmacodynamic effects founded on the specific microcosmic structural relationship between the components and the components within the group. At present, the way of Chinese pharmacopoeia checking the quality of Chinese medicine is mainly depends on controlling the single or multiple targets of ingredients. In fact, this way is out of the overall effectiveness of the Chinese medicine, so we can not thoroughly controlling the quality of Chinese medicine from the essence of the Chinese medicine. Secondly, it's only macro-structural quantity that the Chinese pharmacopoeia just controlling the less effective ingredients, this is not enough to reflect the internal microstructure of the integrity and systematic. In other words, this cannot reflect the structural components of the Chinese medicine (the essence of traditional Chinese medicine). In view of above mentioned reasons, the author propose the new idea on the quality control in the medicine that quantify the ratio structural relationship in component and the ingredients of the components, set the optimal controlling proportion between the components and ingredients. At the same time, author thought we should conduct the depth study in the micro-quantified the multi-component and multi-ingredient, in the process of studying the material basis of Chinese medicine. Therefore, it could establish a more rational basis for the Chinese medicine quality controlling system.

  10. 30 CFR 77.902-2 - Approved ground check systems not employing pilot check wires.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... pilot check wires. 77.902-2 Section 77.902-2 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... Approved ground check systems not employing pilot check wires. Ground check systems not employing pilot check wires shall be approved by the Secretary only after it has been determined that the system...

  11. 30 CFR 77.902-2 - Approved ground check systems not employing pilot check wires.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... pilot check wires. 77.902-2 Section 77.902-2 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... Approved ground check systems not employing pilot check wires. Ground check systems not employing pilot check wires shall be approved by the Secretary only after it has been determined that the system...

  12. 30 CFR 77.902-2 - Approved ground check systems not employing pilot check wires.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... pilot check wires. 77.902-2 Section 77.902-2 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... Approved ground check systems not employing pilot check wires. Ground check systems not employing pilot check wires shall be approved by the Secretary only after it has been determined that the system...

  13. 30 CFR 77.902-2 - Approved ground check systems not employing pilot check wires.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... pilot check wires. 77.902-2 Section 77.902-2 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... Approved ground check systems not employing pilot check wires. Ground check systems not employing pilot check wires shall be approved by the Secretary only after it has been determined that the system...

  14. 30 CFR 77.902-2 - Approved ground check systems not employing pilot check wires.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... pilot check wires. 77.902-2 Section 77.902-2 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... Approved ground check systems not employing pilot check wires. Ground check systems not employing pilot check wires shall be approved by the Secretary only after it has been determined that the system...

  15. Data quality control in eco-environmental monitoring

    NASA Astrophysics Data System (ADS)

    Lu, Chunyan; Wang, Jing

    2007-11-01

    , such as data resource, the number and spatial distribution of the control points are important resource of uncertainty. Attribution uncertainty mainly derived from the process of information extraction. Land classification system, artificial error was the main factor induced uncertainty. Concept defined was not clear, and it reduced thematic uncertainty. According to the resource of uncertainty, data quality control methods were put forward to improve the data quality. At first, it is more important to choose appropriate remote sensing data and other basic data. Secondly, the accuracy of digital orthophoto map should be controlled. Thirdly, it is necessary to check the result data according to relative data quality criterion to guarantee GIS data quality.

  16. 30 CFR 75.902-2 - Approved ground check systems not employing pilot check wires.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Approved ground check systems not employing pilot check wires. 75.902-2 Section 75.902-2 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... employing pilot check wires. Ground check systems not employing pilot check wires will be approved only if...

  17. 30 CFR 75.902-2 - Approved ground check systems not employing pilot check wires.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved ground check systems not employing pilot check wires. 75.902-2 Section 75.902-2 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... employing pilot check wires. Ground check systems not employing pilot check wires will be approved only if...

  18. Model analysis of check dam impacts on long-term sediment and water budgets in southeast Arizona, USA

    USGS Publications Warehouse

    Norman, Laura M.; Niraula, Rewati

    2016-01-01

    The objective of this study was to evaluate the effect of check dam infrastructure on soil and water conservation at the catchment scale using the Soil and Water Assessment Tool (SWAT). This paired watershed study includes a watershed treated with over 2000 check dams and a Control watershed which has none, in the West Turkey Creek watershed, Southeast Arizona, USA. SWAT was calibrated for streamflow using discharge documented during the summer of 2013 at the Control site. Model results depict the necessity to eliminate lateral flow from SWAT models of aridland environments, the urgency to standardize geospatial soils data, and the care for which modelers must document altering parameters when presenting findings. Performance was assessed using the percent bias (PBIAS), with values of ±2.34%. The calibrated model was then used to examine the impacts of check dams at the Treated watershed. Approximately 630 tons of sediment is estimated to be stored behind check dams in the Treated watershed over the 3-year simulation, increasing water quality for fish habitat. A minimum precipitation event of 15 mm was necessary to instigate the detachment of soil, sediments, or rock from the study area, which occurred 2% of the time. The resulting watershed model is useful as a predictive framework and decision-support tool to consider long-term impacts of restoration and potential for future restoration.

  19. Member Checking: A Tool to Enhance Trustworthiness or Merely a Nod to Validation?

    PubMed

    Birt, Linda; Scott, Suzanne; Cavers, Debbie; Campbell, Christine; Walter, Fiona

    2016-06-22

    The trustworthiness of results is the bedrock of high quality qualitative research. Member checking, also known as participant or respondent validation, is a technique for exploring the credibility of results. Data or results are returned to participants to check for accuracy and resonance with their experiences. Member checking is often mentioned as one in a list of validation techniques. This simplistic reporting might not acknowledge the value of using the method, nor its juxtaposition with the interpretative stance of qualitative research. In this commentary, we critique how member checking has been used in published research, before describing and evaluating an innovative in-depth member checking technique, Synthesized Member Checking. The method was used in a study with patients diagnosed with melanoma. Synthesized Member Checking addresses the co-constructed nature of knowledge by providing participants with the opportunity to engage with, and add to, interview and interpreted data, several months after their semi-structured interview. © The Author(s) 2016.

  20. Double checking: a second look

    PubMed Central

    Chreim, Samia; Forster, Alan

    2015-01-01

    Abstract Rationale, aims and objectives Double checking is a standard practice in many areas of health care, notwithstanding the lack of evidence supporting its efficacy. We ask in this study: ‘How do front line practitioners conceptualize double checking? What are the weaknesses of double checking? What alternate views of double checking could render it a more robust process?’ Method This is part of a larger qualitative study based on 85 semi‐structured interviews of health care practitioners in general internal medicine and obstetrics and neonatology; thematic analysis of the transcribed interviews was undertaken. Inductive and deductive themes are reported. Results Weaknesses in the double checking process include inconsistent conceptualization of double checking, double (or more) checking as a costly and time‐consuming procedure, double checking trusted as an accepted and stand‐alone process, and double checking as preventing reporting of near misses. Alternate views of double checking that would render it a more robust process include recognizing that double checking requires training and a dedicated environment, Introducing automated double checking, and expanding double checking beyond error detection. These results are linked with the concepts of collective efficiency thoroughness trade off (ETTO), an in‐family approach, and resilience. Conclusion(s) Double checking deserves more questioning, as there are limitations to the process. Practitioners could view double checking through alternate lenses, and thus help strengthen this ubiquitous practice that is rarely challenged. PMID:26568537

  1. 14 CFR 91.1089 - Qualifications: Check pilots (aircraft) and check pilots (simulator).

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false Qualifications: Check pilots (aircraft) and check pilots (simulator). 91.1089 Section 91.1089 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... RULES Fractional Ownership Operations Program Management § 91.1089 Qualifications: Check pilots...

  2. 14 CFR 91.1089 - Qualifications: Check pilots (aircraft) and check pilots (simulator).

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Qualifications: Check pilots (aircraft) and check pilots (simulator). 91.1089 Section 91.1089 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... RULES Fractional Ownership Operations Program Management § 91.1089 Qualifications: Check pilots...

  3. Primary health-care nurses and Internet health information-seeking: Access, barriers and quality checks.

    PubMed

    Gilmour, Jean; Strong, Alison; Chan, Helen; Hanna, Sue; Huntington, Annette

    2016-02-01

    Online information is a critical resource for evidence-based practice and patient education. This study aimed to establish New Zealand nurses' access and evaluation of online health information in the primary care context using a postal questionnaire survey; there were 630 respondents from a random sample of 931 nurses. The majority of respondents were satisfied with work access to online information (84.5%, n = 501) and searched for online information at least several times a week (57.5%, n = 343). The major barrier to online information seeking was insufficient time, but 68 respondents had no work online information access. The level of nursing qualification was significantly correlated with computer confidence and information quality checking. A range of information evaluation approaches was used. Most nurses in study accessed and evaluated Internet information in contrast to the findings of earlier studies, but there were barriers preventing universal integration into practice. © 2014 Wiley Publishing Asia Pty Ltd.

  4. Fast acting check valve

    NASA Technical Reports Server (NTRS)

    Perkins, Gerald S. (Inventor)

    1979-01-01

    A check valve which closes more rapidly to prevent wearing of the valve seat and of the valve member that seals thereagainst, including a solenoid or other actuator that aids the normal spring to quickly close the valve at approximately the time when downpath fluid flow would stop, the actuator then being deenergized. The control circuit that operates the actuator can include a pair of pressure sensors sensing pressure both upstream and downstream from the valve seat. Where the valve is utilized to control flow to or from a piston pump, energization of the actuator can be controlled by sensing when the pump piston reaches its extreme of travel.

  5. New quality-control materials for the determination of alkylphenols and alkylphenol ethoxylates in sewage sludge.

    PubMed

    Fernández-Sanjuan, María; Lacorte, Silvia; Rigol, Anna; Sahuquillo, Angels

    2012-11-01

    The determination of alkylphenols in sewage sludge is still hindered by the complexity of the matrix and of the analytes, some of which are a mixture of isomers. Most of the methods published in the literature have not been validated, due to the lack of reference materials for the determination of alkylphenols in sludge. Given this situation, the objectives of the present study were to develop a new quality-control material for determining octylphenol, nonylphenol and nonylphenol monoethoxylate in sludge. The material was prepared from an anaerobically digested sewage sludge, which was thermally dried, sieved, homogenized and bottled after checking for the bulk homogeneity of the processed material. Together with the sewage sludge, an extract was also prepared, in order to provide a quality-control material for allowing laboratories to test the measuring step. The homogeneity and 1-year stability of the two materials were evaluated. Statistical analysis proved that the materials were homogeneous and stable for at least 1 year stored at different temperatures. These materials are intended to assist in the quality control of the determination of alkylphenols and alkylphenol ethoxylates in sewage sludge.

  6. Sealed Organic Check Material on Curiosity

    NASA Image and Video Library

    2012-09-10

    NASA Mars rover Curiosity carries five cylindrical blocks of organic check material for use in a control experiment if the rover Sample Analysis at Mars SAM laboratory detects any organic compounds in samples of Martian soil or powdered rock.

  7. Statistical process control analysis for patient quality assurance of intensity modulated radiation therapy

    NASA Astrophysics Data System (ADS)

    Lee, Rena; Kim, Kyubo; Cho, Samju; Lim, Sangwook; Lee, Suk; Shim, Jang Bo; Huh, Hyun Do; Lee, Sang Hoon; Ahn, Sohyun

    2017-11-01

    This study applied statistical process control to set and verify the quality assurances (QA) tolerance standard for our hospital's characteristics with the criteria standards that are applied to all the treatment sites with this analysis. Gamma test factor of delivery quality assurances (DQA) was based on 3%/3 mm. Head and neck, breast, prostate cases of intensity modulated radiation therapy (IMRT) or volumetric arc radiation therapy (VMAT) were selected for the analysis of the QA treatment sites. The numbers of data used in the analysis were 73 and 68 for head and neck patients. Prostate and breast were 49 and 152 by MapCHECK and ArcCHECK respectively. C p value of head and neck and prostate QA were above 1.0, C pml is 1.53 and 1.71 respectively, which is close to the target value of 100%. C pml value of breast (IMRT) was 1.67, data values are close to the target value of 95%. But value of was 0.90, which means that the data values are widely distributed. C p and C pml of breast VMAT QA were respectively 1.07 and 2.10. This suggests that the VMAT QA has better process capability than the IMRT QA. Consequently, we should pay more attention to planning and QA before treatment for breast Radiotherapy.

  8. 30 CFR 75.902-2 - Approved ground check systems not employing pilot check wires.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... pilot check wires. 75.902-2 Section 75.902-2 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... employing pilot check wires. Ground check systems not employing pilot check wires will be approved only if... ground continuity is broken. ...

  9. 30 CFR 75.902-2 - Approved ground check systems not employing pilot check wires.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... pilot check wires. 75.902-2 Section 75.902-2 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... employing pilot check wires. Ground check systems not employing pilot check wires will be approved only if... ground continuity is broken. ...

  10. 30 CFR 75.902-2 - Approved ground check systems not employing pilot check wires.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... pilot check wires. 75.902-2 Section 75.902-2 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... employing pilot check wires. Ground check systems not employing pilot check wires will be approved only if... ground continuity is broken. ...

  11. [Coronary artery bypass surgery: methods of performance monitoring and quality control].

    PubMed

    Albert, A; Sergeant, P; Ennker, J

    2009-10-01

    The strength of coronary bypass operations depends on the preservation of their benefits regarding freedom of symptoms, quality of life and survival, over decades. Significant variability of the results of an operative intervention according to the hospital or the operating surgeon is considered a weakness in the procedure. The external quality insurance tries to reach a transparent service providing market through hospital ranking comparability. Widely available information and competition will promote the improvement of the whole quality. The structured dialog acts as a control instrument for the BQS (Federal Quality Insurance). It is launched in case of deviations from the standard references or statistically significant differences between the results of the operations in any hospital and the average notational results. In comparison to the external control the hospital internal control has greater ability to reach a medically useful statement regarding the results of the treatment and to correct the mistakes in time. An online information portal based on a departmental databank (DataWarehouse, DataMart) is an attractive solution for the physician in order to get transparently and timely informed about the variability in the performance.The individual surgeon significantly influences the short- and long-term treatment results. Accordingly, selection, targeted training and performance measurements are necessary.Strict risk management and failure analysis of individual cases are included in the methods of internal quality control aiming to identify and correct the inadequacies in the system and the course of treatment. According to the international as well as our own experience, at least 30% of the mortalities after bypass operations are avoidable. A functioning quality control is especially important in minimally invasive interventions because they are often technically more demanding in comparison to the conventional procedures. In the field of OPCAB surgery

  12. QUALITY CONTROLS FOR PCR

    EPA Science Inventory

    The purpose of this presentation is to present an overview of the quality control (QC) sections of a draft EPA document entitled, "Quality Assurance/Quality Control Guidance for Laboratories Performing PCR Analyses on Environmental Samples." This document has been prepared by th...

  13. Reality check of socio-hydrological interactions in water quality and ecosystem management

    NASA Astrophysics Data System (ADS)

    Destouni, Georgia; Fischer, Ida; Prieto, Carmen

    2017-04-01

    Socio-hydrological interactions in water management for improving water quality and ecosystem status include as key components both (i) the societal measures taken for mitigation and control, and (ii) the societal characterization and monitoring efforts made for choosing management targets and checking the effects of measures taken to reach the targets. This study investigates such monitoring, characterization and management efforts and effects over the first six-year management cycle of the EU Water Framework Directive (WFD). The investigation uses Sweden and the WFD-regulated management of its stream and lake waters as a concrete quantification example, with focus on the nutrient and eutrophication conditions that determine the most prominent water quality and ecosystem problems in need of mitigation in the Swedish waters. The case results show a relatively small available monitoring base for determination of these nutrient and eutrophication conditions, even though they constitute key parts in the overall WFD-based approach to classification and management of ecosystem status. Specifically, actual nutrient monitoring exists in only around 1% (down to 0.2% for nutrient loads) of the Swedish stream and lake water bodies; modeling is used to fill the gaps for the remaining unmonitored fraction of classified and managed waters. The available data show that the hydro-climatically driven stream water discharge is a primary explanatory variable for the resulting societal classification of ecosystem status in Swedish waters; this may be due to the discharge magnitude being dominant in determining nutrient loading to these waters. At any rate, with such a hydro-climatically related, rather than human-pressure related, determinant of the societal ecosystem-status classification, the main human-driven causes and effects of eutrophication may not be appropriately identified, and the measures taken for mitigating these may not be well chosen. The available monitoring data

  14. The impact of gender on the assessment of body checking behavior.

    PubMed

    Alfano, Lauren; Hildebrandt, Tom; Bannon, Katie; Walker, Catherine; Walton, Kate E

    2011-01-01

    Body checking includes any behavior aimed at global or specific evaluations of appearance characteristics. Men and women are believed to express these behaviors differently, possibly reflecting different socialization. However, there has been no empirical test of the impact of gender on body checking. A total of 1024 male and female college students completed two measures of body checking, the Body Checking Questionnaire and the Male Body Checking Questionnaire. Using multiple group confirmatory factor analysis, differential item functioning (DIF) was explored in a composite of these measures. Two global latent factors were identified (female and male body checking severity), and there were expected gender differences in these factors even after controlling for DIF. Ten items were found to be unbiased by gender and provide a suitable brief measure of body checking for mixed gender research. Practical applications for body checking assessment and theoretical implications are discussed. Copyright © 2010 Elsevier Ltd. All rights reserved.

  15. 42 CFR 493.1254 - Standard: Maintenance and function checks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Maintenance and function checks. 493.1254 Section 493.1254 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS Quality System for Nonwaived...

  16. Do alcohol compliance checks decrease underage sales at neighboring establishments?

    PubMed

    Erickson, Darin J; Smolenski, Derek J; Toomey, Traci L; Carlin, Bradley P; Wagenaar, Alexander C

    2013-11-01

    Underage alcohol compliance checks conducted by law enforcement agencies can reduce the likelihood of illegal alcohol sales at checked alcohol establishments, and theory suggests that an alcohol establishment that is checked may warn nearby establishments that compliance checks are being conducted in the area. In this study, we examined whether the effects of compliance checks diffuse to neighboring establishments. We used data from the Complying with the Minimum Drinking Age trial, which included more than 2,000 compliance checks conducted at more than 900 alcohol establishments. The primary outcome was the sale of alcohol to a pseudo-underage buyer without the need for age identification. A multilevel logistic regression was used to model the effect of a compliance check at each establishment as well as the effect of compliance checks at neighboring establishments within 500 m (stratified into four equal-radius concentric rings), after buyer, license, establishment, and community-level variables were controlled for. We observed a decrease in the likelihood of establishments selling alcohol to underage youth after they had been checked by law enforcement, but these effects quickly decayed over time. Establishments that had a close neighbor (within 125 m) checked in the past 90 days were also less likely to sell alcohol to young-appearing buyers. The spatial effect of compliance checks on other establishments decayed rapidly with increasing distance. Results confirm the hypothesis that the effects of police compliance checks do spill over to neighboring establishments. These findings have implications for the development of an optimal schedule of police compliance checks.

  17. SU-F-T-459: ArcCHECK Machine QA : Highly Efficient Quality Assurance Tool for VMAT, SRS & SBRT Linear Accelerator Delivery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mhatre, V; Patwe, P; Dandekar, P

    Purpose: Quality assurance (QA) of complex linear accelerators is critical and highly time consuming. ArcCHECK Machine QA tool is used to test geometric and delivery aspects of linear accelerator. In this study we evaluated the performance of this tool. Methods: Machine QA feature allows user to perform quality assurance tests using ArcCHECK phantom. Following tests were performed 1) Gantry Speed 2) Gantry Rotation 3) Gantry Angle 4)MLC/Collimator QA 5)Beam Profile Flatness & Symmetry. Data was collected on trueBEAM stX machine for 6 MV for a period of one year. The Gantry QA test allows to view errors in gantry angle,more » rotation & assess how accurately the gantry moves around the isocentre. The MLC/Collimator QA tool is used to analyze & locate the differences between leaf bank & jaw position of linac. The flatness & Symmetry test quantifies beam flatness & symmetry in IEC-y & x direction. The Gantry & Flatness/Symmetry test can be performed for static & dynamic delivery. Results: The Gantry speed was 3.9 deg/sec with speed maximum deviation around 0.3 deg/sec. The Gantry Isocentre for arc delivery was 0.9mm & static delivery was 0.4mm. The maximum percent positive & negative difference was found to be 1.9 % & – 0.25 % & maximum distance positive & negative diff was 0.4mm & – 0.3 mm for MLC/Collimator QA. The Flatness for Arc delivery was 1.8 % & Symmetry for Y was 0.8 % & X was 1.8 %. The Flatness for gantry 0°,270°,90° & 180° was 1.75,1.9,1.8 & 1.6% respectively & Symmetry for X & Y was 0.8,0.6% for 0°, 0.6,0.7% for 270°, 0.6,1% for 90° & 0.6,0.7% for 180°. Conclusion: ArcCHECK Machine QA is an useful tool for QA of Modern linear accelerators as it tests both geometric & delivery aspects. This is very important for VMAT, SRS & SBRT treatments.« less

  18. 14 CFR 135.337 - Qualifications: Check airmen (aircraft) and check airmen (simulator).

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... who is qualified to conduct flight checks in an aircraft, in a flight simulator, or in a flight... to conduct flight checks, but only in a flight simulator, in a flight training device, or both, for a... the 12-month preceding the performance of any check airman duty in a flight simulator; or (2...

  19. 14 CFR 135.337 - Qualifications: Check airmen (aircraft) and check airmen (simulator).

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... who is qualified to conduct flight checks in an aircraft, in a flight simulator, or in a flight... to conduct flight checks, but only in a flight simulator, in a flight training device, or both, for a... the 12-month preceding the performance of any check airman duty in a flight simulator; or (2...

  20. 14 CFR 135.337 - Qualifications: Check airmen (aircraft) and check airmen (simulator).

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... who is qualified to conduct flight checks in an aircraft, in a flight simulator, or in a flight... to conduct flight checks, but only in a flight simulator, in a flight training device, or both, for a... the 12-month preceding the performance of any check airman duty in a flight simulator; or (2...

  1. 14 CFR 135.337 - Qualifications: Check airmen (aircraft) and check airmen (simulator).

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... who is qualified to conduct flight checks in an aircraft, in a flight simulator, or in a flight... to conduct flight checks, but only in a flight simulator, in a flight training device, or both, for a... the 12-month preceding the performance of any check airman duty in a flight simulator; or (2...

  2. [On-site quality control of acupuncture randomized controlled trial: design of content and checklist of quality control based on PICOST].

    PubMed

    Li, Hong-Jiao; He, Li-Yun; Liu, Zhi-Shun; Sun, Ya-Nan; Yan, Shi-Yan; Liu, Jia; Zhao, Ye; Liu, Bao-Yan

    2014-02-01

    To effectively guarantee quality of randomized controlld trial (RCT) of acupuncture and develop reasonable content and checklist of on-site quality control, influencing factors on quality of acupuncture RCT are analyzed and scientificity of quality control content and feasibility of on-site manipulation are put into overall consideration. Based on content and checklist of on-site quality control in National 11th Five-Year Plan Project Optimization of Comprehensive Treatment Plan for TCM in Prevention and Treatment of Serious Disease and Clinical Assessment on Generic Technology and Quality Control Research, it is proposed that on-site quality control of acupuncture RCT should be conducted with PICOST (patient, intervention, comparison, out come, site and time) as core, especially on quality control of interveners' skills and outcome assessment of blinding, and checklist of on-site quality control is developed to provide references for undertaking groups of the project.

  3. 14 CFR 91.1093 - Initial and transition training and checking: Check pilots (aircraft), check pilots (simulator).

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... observation check may be accomplished in part or in full in an aircraft, in a flight simulator, or in a flight... accomplished in full or in part in flight, in a flight simulator, or in a flight training device, as appropriate. (g) The initial and transition flight training for a check pilot (simulator) must include the...

  4. 14 CFR 91.1093 - Initial and transition training and checking: Check pilots (aircraft), check pilots (simulator).

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... observation check may be accomplished in part or in full in an aircraft, in a flight simulator, or in a flight... accomplished in full or in part in flight, in a flight simulator, or in a flight training device, as appropriate. (g) The initial and transition flight training for a check pilot (simulator) must include the...

  5. 14 CFR 91.1093 - Initial and transition training and checking: Check pilots (aircraft), check pilots (simulator).

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... observation check may be accomplished in part or in full in an aircraft, in a flight simulator, or in a flight... accomplished in full or in part in flight, in a flight simulator, or in a flight training device, as appropriate. (g) The initial and transition flight training for a check pilot (simulator) must include the...

  6. 14 CFR 91.1093 - Initial and transition training and checking: Check pilots (aircraft), check pilots (simulator).

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... observation check may be accomplished in part or in full in an aircraft, in a flight simulator, or in a flight... accomplished in full or in part in flight, in a flight simulator, or in a flight training device, as appropriate. (g) The initial and transition flight training for a check pilot (simulator) must include the...

  7. 14 CFR 91.1093 - Initial and transition training and checking: Check pilots (aircraft), check pilots (simulator).

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... observation check may be accomplished in part or in full in an aircraft, in a flight simulator, or in a flight... accomplished in full or in part in flight, in a flight simulator, or in a flight training device, as appropriate. (g) The initial and transition flight training for a check pilot (simulator) must include the...

  8. Simple Field Assays to Check Quality of Current Artemisinin-Based Antimalarial Combination Formulations

    PubMed Central

    Ioset, Jean-Robert; Kaur, Harparkash

    2009-01-01

    Introduction Malaria continues to be one of the major public health problems in Africa, Asia and Latin America. Artemisinin derivatives (ARTs; artesunate, artemether, and dihydroartemisinin) derived from the herb, Artemisia annua, are the most effective antimalarial drugs available providing rapid cures. The World Health Organisation (WHO) has recommended that all antimalarials must be combined with an artemisinin component (artemisinin-based combination therapy; ACT) for use as first line treatment against malaria. This class of drugs is now first-line policy in most malaria-endemic countries. Reports of ad hoc surveys from South East Asia show that up to 50% of the artesunate currently sold is counterfeit. Drug quality is rarely assessed in resource poor countries in part due to lack of dedicated laboratory facilities which are expensive to build, equip and maintain. With a view to address this unmet need we developed two novel colour reaction assays that can be used in the field to check the quality of ARTs. Methods and Findings Our assays utilise thin layer chromatography silica gel sheets and 2, 4 dinitrophenylhydrazine or 4-Benzoylamino-2, 5-dimethoxybenzenediazonium chloride hemi (zinc chloride) salt as the reagents showing a pink or blue product respectively only in the presence ARTs. We are able to detect as low as 10% of ARTs in ACTs (WINTHROP - artesunate/amodiaquine, Coartem®-artemether/lumefantrine and Duocortexcin - dihydroartemisinin/piperaquine). The assays have been validated extensively by testing eighty readily accessible and widely used drugs in malaria endemic countries. None of the other antimalarial drugs or a range of commonly used excipients, antiretroviral drugs or other frequently used drugs from the WHO essential drugs list such as analgesics or antibiotics are detected with our assays. Conclusions Our two independent assays requiring no specialist training are specific, simple to use, rapid, robust, reproducible, inexpensive and, have

  9. Parallel Software Model Checking

    DTIC Science & Technology

    2015-01-08

    checker. This project will explore this strategy to parallelize the generalized PDR algorithm for software model checking. It belongs to TF1 due to its ... focus on formal verification . Generalized PDR. Generalized Property Driven Rechability (GPDR) i is an algorithm for solving HORN-SMT reachability...subject to a penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. 1. REPORT DATE 08

  10. Method and apparatus for checking fire detectors

    NASA Technical Reports Server (NTRS)

    Clawson, G. T. (Inventor)

    1974-01-01

    A fire detector checking method and device are disclosed for nondestructively verifying the operation of installed fire detectors of the type which operate on the principle of detecting the rate of temperature rise of the ambient air to sound an alarm and/or which sound an alarm when the temperature of the ambient air reaches a preset level. The fire alarm checker uses the principle of effecting a controlled simulated alarm condition to ascertain wheather or not the detector will respond. The checker comprises a hand-held instrument employing a controlled heat source, e.g., an electric lamp having a variable input, for heating at a controlled rate an enclosed mass of air in a first compartment, which air mass is then disposed about the fire detector to be checked. A second compartment of the device houses an electronic circuit to sense and adjust the temperature level and heating rate of the heat source.

  11. The DD Check App for prevention and control of digital dermatitis in dairy herds.

    PubMed

    Tremblay, Marlène; Bennett, Tom; Döpfer, Dörte

    2016-09-15

    Digital dermatitis (DD) is the most important infectious claw disease in the cattle industry causing outbreaks of lameness. The clinical course of disease can be classified using 5 clinical stages. M-stages represent not only different disease severities but also unique clinical characteristics and outcomes. Monitoring the proportions of cows per M-stage is needed to better understand and address DD and factors influencing risks of DD in a herd. Changes in the proportion of cows per M-stage over time or between groups may be attributed to differences in management, environment, or treatment and can have impact on the future claw health of the herd. Yet trends in claw health regarding DD are not intuitively noticed without statistical analysis of detailed records. Our specific aim was to develop a mobile application (app) for persons with less statistical training, experience or supporting programs that would standardize M-stage records, automate data analysis including trends of M-stages over time, the calculation of predictions and assignments of Cow Types (i.e., Cow Types I-III are assigned to cows without active lesions, single and repeated cases of active DD lesions, respectively). The predictions were the stationary distributions of transitions between DD states (i.e., M-stages or signs of chronicity) in a class-structured multi-state Markov chain population model commonly used to model endemic diseases. We hypothesized that the app can be used at different levels of record detail to discover significant trends in the prevalence of M-stages that help to make informed decisions to prevent and control DD on-farm. Four data sets were used to test the flexibility and value of the DD Check App. The app allows easy recording of M-stages in different environments and is flexible in terms of the users' goals and the level of detail used. Results show that this tool discovers trends in M-stage proportions, predicts potential outbreaks of DD, and makes comparisons among

  12. Model Checking the Remote Agent Planner

    NASA Technical Reports Server (NTRS)

    Khatib, Lina; Muscettola, Nicola; Havelund, Klaus; Norvig, Peter (Technical Monitor)

    2001-01-01

    This work tackles the problem of using Model Checking for the purpose of verifying the HSTS (Scheduling Testbed System) planning system. HSTS is the planner and scheduler of the remote agent autonomous control system deployed in Deep Space One (DS1). Model Checking allows for the verification of domain models as well as planning entries. We have chosen the real-time model checker UPPAAL for this work. We start by motivating our work in the introduction. Then we give a brief description of HSTS and UPPAAL. After that, we give a sketch for the mapping of HSTS models into UPPAAL and we present samples of plan model properties one may want to verify.

  13. [Quality control in anesthesiology].

    PubMed

    Muñoz-Ramón, J M

    1995-03-01

    The process of quality control and auditing of anesthesiology allows us to evaluate care given by a service and solve problems that are detected. Quality control is a basic element of care giving and is only secondarily an area of academic research; it is therefore a meaningless effort if the information does not serve to improve departmental procedures. Quality assurance procedures assume certain infrastructural requirements and an initial period of implementation and adjustment. The main objectives of quality control are the reduction of morbidity and mortality due to anesthesia, assurance of the availability and proper management of resources and, finally, the well-being and safety of the patient.

  14. Check-Up Checklist: Things to Do Before Your Next Check-Up

    MedlinePlus

    ... Halloween Prom Tips Spring Break Valentine Tips Winter Holiday Tips 12 Ways Holiday Song Healthy Living Check-Ups are Important Check- ... Test Wash Hands Stay Warm Have a Healthy Holiday Don’t Drink and Drive Widgets Healthy People ...

  15. Interface Circuits for Self-Checking Microprocessors

    NASA Technical Reports Server (NTRS)

    Rennels, D. A.; Chandramouli, R.

    1986-01-01

    Fault-tolerant-microcomputer concept based on enhancing "simple" computer with redundancy and self-checking logic circuits detect hardware faults. Interface and checking logic and redundant processors confer on 16-bit microcomputer ability to check itself for hardware faults. Checking circuitry also checks itself. Concept of self-checking complementary pairs (SCCP's) employed throughout ICL unit.

  16. Effectiveness of the population-based Check your health preventive programme conducted in primary care with 4 years follow-up [the CORE trial]: study protocol for a randomised controlled trial.

    PubMed

    Maindal, Helle Terkildsen; Støvring, Henrik; Sandbaek, Annelli

    2014-08-29

    The periodic health check-up has been a fundamental part of routine medical practice for decades, despite a lack of consensus regarding its value in health promotion and disease prevention. A large-scale Danish population-based preventive programme 'Check your health' was developed based on available evidence of screening and successive accepted treatment, prevention for diseases and health promotion, and is closely aligned with the current health care system.The objective of the 'Check your health' [CORE] trial is to investigate effectiveness on health outcomes of a preventive health check offered at a population-level to all individuals aged 30-49 years, and to establish the cost-effectiveness. The trial will be conducted as a pragmatic household-cluster randomised controlled trial involving 10,505 individuals. All individuals within a well-defined geographical area in the Central Denmark Region, Denmark (DK) were randomised to be offered a preventive health check (Intervention group, n = 5250) or to maintain routine access to healthcare until a delayed intervention (Comparison group, n = 5255). The programme consists of a health examination which yields an individual risk profile, and according to this participants are assigned to one of the following interventions: (a) referral to a health promoting consultation in general practice, (b) behavioural programmes at the local Health Centre, or (c) no need for follow-up.The primary outcomes at 4 years follow-up are: ten-year-risk of fatal cardiovascular event (Heart-SCORE model), physical activity level (self-report and cardiorespiratory fitness), quality of life (SF12), sick leave and labour market attachment. Cost-effectiveness will be evaluated according to life years gained, direct costs and total health costs. Intention to treat analysis will be performed. Results from the largest Danish health check programme conducted within the current healthcare system, spanning the sectors which share responsibility for

  17. Model Checking Verification and Validation at JPL and the NASA Fairmont IV and V Facility

    NASA Technical Reports Server (NTRS)

    Schneider, Frank; Easterbrook, Steve; Callahan, Jack; Montgomery, Todd

    1999-01-01

    We show how a technology transfer effort was carried out. The successful use of model checking on a pilot JPL flight project demonstrates the usefulness and the efficacy of the approach. The pilot project was used to model a complex spacecraft controller. Software design and implementation validation were carried out successfully. To suggest future applications we also show how the implementation validation step can be automated. The effort was followed by the formal introduction of the modeling technique as a part of the JPL Quality Assurance process.

  18. An Envelope Based Feedback Control System for Earthquake Early Warning: Reality Check Algorithm

    NASA Astrophysics Data System (ADS)

    Heaton, T. H.; Karakus, G.; Beck, J. L.

    2016-12-01

    Earthquake early warning systems are, in general, designed to be open loop control systems in such a way that the output, i.e., the warning messages, only depend on the input, i.e., recorded ground motions, up to the moment when the message is issued in real-time. We propose an algorithm, which is called Reality Check Algorithm (RCA), which would assess the accuracy of issued warning messages, and then feed the outcome of the assessment back into the system. Then, the system would modify its messages if necessary. That is, we are proposing to convert earthquake early warning systems into feedback control systems by integrating them with RCA. RCA works by continuously monitoring and comparing the observed ground motions' envelopes to the predicted envelopes of Virtual Seismologist (Cua 2005). Accuracy of magnitude and location (both spatial and temporal) estimations of the system are assessed separately by probabilistic classification models, which are trained by a Sparse Bayesian Learning technique called Automatic Relevance Determination prior.

  19. SpermCheck: a simplified screening assay for immunological infertility.

    PubMed

    McClure, R D; Tom, R A; Watkins, M; Murthy, S

    1989-10-01

    SpermCheck (Bio-Rad Laboratories, Hercules, CA), a new screening test for regional surface antibodies on motile sperm, uses monodispersed latex microspheres of uniform size as a vehicle to link rabbit antihuman immunoglobulins (IgA, IgG, IgM) and provides both negative and positive control sera, as well as sufficient buffer for sperm preparation in ambient CO2 atmosphere. When compared with reference data available for the immunobead test (IBT), the direct protocol (semen) for SpermCheck yielded 94.4% sensitivity with 100% specificity; the indirect protocol (serum) provided a sensitivity of 100% with 94.7% specificity. The microspheres of SpermCheck maintain a nearly uniform concentration per volume, with none to negligible clumping. The greater difference between the optical densities of latex and cytoplasm allows use of a light microscope for the rapid assessment of the percent of regional binding rather than the phase-contrast microscope required for the IBT. SpermCheck eliminates many difficulties encountered with the IBT, making SpermCheck a convenient screening assay for use in the physician's office.

  20. Assessing Educational Processes Using Total-Quality-Management Measurement Tools.

    ERIC Educational Resources Information Center

    Macchia, Peter, Jr.

    1993-01-01

    Discussion of the use of Total Quality Management (TQM) assessment tools in educational settings highlights and gives examples of fishbone diagrams, or cause and effect charts; Pareto diagrams; control charts; histograms and check sheets; scatter diagrams; and flowcharts. Variation and quality are discussed in terms of continuous process…

  1. Health Checks in Primary Care for Adults with Intellectual Disabilities: How Extensive Should They Be?

    ERIC Educational Resources Information Center

    Chauhan, U.; Kontopantelis, E.; Campbell, S.; Jarrett, H.; Lester, H.

    2010-01-01

    Background: Routine health checks have gained prominence as a way of detecting unmet need in primary care for adults with intellectual disabilities (ID) and general practitioners are being incentivised in the UK to carry out health checks for many conditions through an incentivisation scheme known as the Quality and Outcomes Framework (QOF).…

  2. Commercial jet fuel quality control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strauss, K.H.

    1995-05-01

    The paper discusses the purpose of jet fuel quality control between the refinery and the aircraft. It describes fixed equipment, including various types of filters, and the usefulness and limitations of this equipment. Test equipment is reviewed as are various surveillance procedures. These include the Air Transport Association specification ATA 103, the FAA Advisory Circular 150/5230-4, the International Air Transport Association Guidance Material for Fuel Quality Control and Fuelling Service and the Guidelines for Quality Control at Jointly Operated Fuel Systems. Some past and current quality control problems are briefly mentioned.

  3. 32 CFR Attachment A to Subpart B... - Standard A-National Agency Check With Local Agency Checks and Credit Check (NACLC)

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... documentation, if not completed in any previous investigation; a check of Bureau of Vital Statistics records when any discrepancy is found to exist. (5) Local Agency Checks: As a minimum, all investigations will...

  4. 32 CFR Attachment A to Subpart B... - Standard A-National Agency Check With Local Agency Checks and Credit Check (NACLC)

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... documentation, if not completed in any previous investigation; a check of Bureau of Vital Statistics records when any discrepancy is found to exist. (5) Local Agency Checks: As a minimum, all investigations will...

  5. 32 CFR Attachment A to Subpart B... - Standard A-National Agency Check With Local Agency Checks and Credit Check (NACLC)

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... documentation, if not completed in any previous investigation; a check of Bureau of Vital Statistics records when any discrepancy is found to exist. (5) Local Agency Checks: As a minimum, all investigations will...

  6. 32 CFR Attachment A to Subpart B... - Standard A-National Agency Check With Local Agency Checks and Credit Check (NACLC)

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... documentation, if not completed in any previous investigation; a check of Bureau of Vital Statistics records when any discrepancy is found to exist. (5) Local Agency Checks: As a minimum, all investigations will...

  7. 32 CFR Attachment A to Subpart B... - Standard A-National Agency Check With Local Agency Checks and Credit Check (NACLC)

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... documentation, if not completed in any previous investigation; a check of Bureau of Vital Statistics records when any discrepancy is found to exist. (5) Local Agency Checks: As a minimum, all investigations will...

  8. Pre-resistance-welding resistance check

    DOEpatents

    Destefan, Dennis E.; Stompro, David A.

    1991-01-01

    A preweld resistance check for resistance welding machines uses an open circuited measurement to determine the welding machine resistance, a closed circuit measurement to determine the parallel resistance of a workpiece set and the machine, and a calculation to determine the resistance of the workpiece set. Any variation in workpiece set or machine resistance is an indication that the weld may be different from a control weld.

  9. Simple colonoscopy reporting system checking the detection rate of colon polyps.

    PubMed

    Kim, Jae Hyun; Choi, Youn Jung; Kwon, Hye Jung; Park, Seun Ja; Park, Moo In; Moon, Won; Kim, Sung Eun

    2015-08-21

    To present a simple colonoscopy reporting system that can be checked easily the detection rate of colon polyps. A simple colonoscopy reporting system Kosin Gastroenterology (KG quality reporting system) was developed. The polyp detection rate (PDR), adenoma detection rate (ADR), serrated polyp detection rate (SDR), and advanced adenoma detection rate (AADR) are easily calculated to use this system. In our gastroenterology center, the PDR, ADR, SDR, and AADR test results from each gastroenterologist were updated, every month. Between June 2014, when the program was started, and December 2014, the overall PDR and ADR in our center were 62.5% and 41.4%, respectively. And the overall SDR and AADR were 7.5% and 12.1%, respectively. We envision that KG quality reporting system can be applied to develop a comprehensive system to check colon polyp detection rates in other gastroenterology centers.

  10. The need for a formalised system of Quality Control for environmental policy-science.

    PubMed

    Larcombe, Piers; Ridd, Peter

    2018-01-01

    Research science used to inform public policy decisions, herein defined as "Policy-Science", is rarely subjected to rigorous checking, testing and replication. Studies of biomedical and other sciences indicate that a considerable fraction of published peer-reviewed scientific literature, perhaps half, has significant flaws. To demonstrate the potential failings of the present approaches to scientific Quality Control (QC), we describe examples of science associated with perceived threats to the Great Barrier Reef (GBR), Australia. There appears a serious risk of efforts to improve the health of the GBR being directed inefficiently and/or away from the more serious threats. We suggest the need for a new organisation to undertake quality reviews and audits of important scientific results that underpin government spending decisions on the environment. Logically, such a body could also examine policy science in other key areas where governments rely heavily upon scientific results, such as education, health and criminology. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Power quality improvement by using STATCOM control scheme in wind energy generation interface to grid

    NASA Astrophysics Data System (ADS)

    Kirmani, Sheeraz; Kumar, Brijesh

    2018-01-01

    “Electric Power Quality (EPQ) is a term that refers to maintaining the near sinusoidal waveform of power distribution bus voltages and currents at rated magnitude and frequency”. Today customers are more aware of the seriousness that the power quality possesses, this prompt the utilities to assure good quality of power to their customer. The power quality is basically customer centric. Increased focus of utilities toward maintaining reliable power supply by employing power quality improvement tools has reduced the power outages and black out considerably. Good power quality is the characteristic of reliable power supply. Low power factor, harmonic pollution, load imbalance, fast voltage variations are some common parameters which are used to define the power quality. If the power quality issues are not checked i.e. the parameters that define power quality doesn't fall within the predefined standards than it will lead into high electricity bill, high running cost in industries, malfunctioning of equipments, challenges in connecting renewable. Capacitor banks, FACTS devices, harmonic filters, SVC’s (static voltage compensators), STATCOM (Static-Compensator) are the solutions to achieve the power quality. The performance of Wind turbine generators is affected by poor quality power, at the same time these wind power generating plant affects the power quality negatively. This paper presents the STATCOM-BESS (battery energy storage system) system and studies its impact on the power quality in a system which consists of wind turbine generator, non linear load, hysteresis controller for controlling the operation of STATCOM and grid. The model is simulated in the MATLAB/Simulink. This scheme mitigates the power quality issues, improves voltage profile and also reduces harmonic distortion of the waveforms. BESS level out the imbalances caused in real power due to intermittent nature of wind power available due to varying wind speeds.

  12. Diagnosis checking of statistical analysis in RCTs indexed in PubMed.

    PubMed

    Lee, Paul H; Tse, Andy C Y

    2017-11-01

    Statistical analysis is essential for reporting of the results of randomized controlled trials (RCTs), as well as evaluating their effectiveness. However, the validity of a statistical analysis also depends on whether the assumptions of that analysis are valid. To review all RCTs published in journals indexed in PubMed during December 2014 to provide a complete picture of how RCTs handle assumptions of statistical analysis. We reviewed all RCTs published in December 2014 that appeared in journals indexed in PubMed using the Cochrane highly sensitive search strategy. The 2014 impact factors of the journals were used as proxies for their quality. The type of statistical analysis used and whether the assumptions of the analysis were tested were reviewed. In total, 451 papers were included. Of the 278 papers that reported a crude analysis for the primary outcomes, 31 (27·2%) reported whether the outcome was normally distributed. Of the 172 papers that reported an adjusted analysis for the primary outcomes, diagnosis checking was rarely conducted, with only 20%, 8·6% and 7% checked for generalized linear model, Cox proportional hazard model and multilevel model, respectively. Study characteristics (study type, drug trial, funding sources, journal type and endorsement of CONSORT guidelines) were not associated with the reporting of diagnosis checking. The diagnosis of statistical analyses in RCTs published in PubMed-indexed journals was usually absent. Journals should provide guidelines about the reporting of a diagnosis of assumptions. © 2017 Stichting European Society for Clinical Investigation Journal Foundation.

  13. 40 CFR 75.21 - Quality assurance and quality control requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Quality assurance and quality control... PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Operation and Maintenance Requirements § 75.21 Quality assurance and quality control requirements. (a) Continuous emission monitoring systems. The owner or...

  14. A Mixed-Method Efficacy and Fidelity Study of Check and Connect

    ERIC Educational Resources Information Center

    Powers, Kristin; Hagans, Kristi; Linn, Megan

    2017-01-01

    The effectiveness of the Check and Connect dropout prevention program was examined, over the course of 2.5 years, with 54 middle school students from diverse backgrounds experiencing one or more conditions of risk for dropout. Participants were randomly assigned to receive the Check and Connect intervention or business as usual (i.e., control) in…

  15. 40 CFR 51.359 - Quality control.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 2 2013-07-01 2013-07-01 false Quality control. 51.359 Section 51.359....359 Quality control. Quality control measures shall insure that emission testing equipment is calibrated and maintained properly, and that inspection, calibration records, and control charts are...

  16. 40 CFR 51.359 - Quality control.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Quality control. 51.359 Section 51.359....359 Quality control. Quality control measures shall insure that emission testing equipment is calibrated and maintained properly, and that inspection, calibration records, and control charts are...

  17. 40 CFR 51.359 - Quality control.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 2 2011-07-01 2011-07-01 false Quality control. 51.359 Section 51.359....359 Quality control. Quality control measures shall insure that emission testing equipment is calibrated and maintained properly, and that inspection, calibration records, and control charts are...

  18. 40 CFR 51.359 - Quality control.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 2 2012-07-01 2012-07-01 false Quality control. 51.359 Section 51.359....359 Quality control. Quality control measures shall insure that emission testing equipment is calibrated and maintained properly, and that inspection, calibration records, and control charts are...

  19. Large-Scale Implementation of Check-In, Check-Out: A Descriptive Study

    ERIC Educational Resources Information Center

    Hawken, Leanne S.; Bundock, Kaitlin; Barrett, Courtenay A.; Eber, Lucille; Breen, Kimberli; Phillips, Danielle

    2015-01-01

    Check-In, Check-Out (CICO) is one of the most widely implemented Tier 2 behavior interventions in a school-wide system of Positive Behavior Interventions and Supports (PBIS). Much literature has documented implementation of CICO across individual schools or districts. The Illinois PBIS Network, currently known as the Midwest PBIS Network, has…

  20. Quality control in gastrointestinal surgery.

    PubMed

    Ramírez-Barba, Ector Jaime; Arenas-Moya, Diego; Vázquez-Guerrero, Arturo

    2011-01-01

    We analyzed the Mexican legal framework, identifying the vectors that characterize quality and control in gastrointestinal surgery. Quality is contemplated in the health protection rights determined according to the Mexican Constitution, established in the general health law and included as a specific goal in the actual National Development Plan and Health Sector Plan. Quality control implies planning, verification and application of corrective measures. Mexico has implemented several quality strategies such as certification of hospitals and regulatory agreements by the General Salubrity Council, creation of the National Health Quality Committee, generation of Clinical Practice Guidelines and the Certification of Medical Specialties, among others. Quality control in gastrointestinal surgery must begin at the time of medical education and continue during professional activities of surgeons, encouraging multidisciplinary teamwork, knowledge, abilities, attitudes, values and skills that promote homogeneous, safe and quality health services for the Mexican population.

  1. 40 CFR 86.322-79 - NDIR CO2 rejection ratio check.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 19 2012-07-01 2012-07-01 false NDIR CO2 rejection ratio check. 86.322... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission....322-79 NDIR CO2 rejection ratio check. (a) Zero and span the analyzer on the lowest range that will be...

  2. 40 CFR 86.322-79 - NDIR CO2 rejection ratio check.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 19 2013-07-01 2013-07-01 false NDIR CO2 rejection ratio check. 86.322... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission....322-79 NDIR CO2 rejection ratio check. (a) Zero and span the analyzer on the lowest range that will be...

  3. 40 CFR 86.322-79 - NDIR CO2 rejection ratio check.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 18 2011-07-01 2011-07-01 false NDIR CO2 rejection ratio check. 86.322... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission....322-79 NDIR CO2 rejection ratio check. (a) Zero and span the analyzer on the lowest range that will be...

  4. 40 CFR 86.322-79 - NDIR CO2 rejection ratio check.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false NDIR CO2 rejection ratio check. 86.322... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission....322-79 NDIR CO2 rejection ratio check. (a) Zero and span the analyzer on the lowest range that will be...

  5. Quality-control issues on high-resolution diagnostic monitors.

    PubMed

    Parr, L F; Anderson, A L; Glennon, B K; Fetherston, P

    2001-06-01

    Previous literature indicates a need for more data collection in the area of quality control of high-resolution diagnostic monitors. Throughout acceptance testing, which began in June 2000, stability of monitor calibration was analyzed. Although image quality on all monitors was found to be acceptable upon initial acceptance testing using VeriLUM software by Image Smiths, Inc (Germantown, MD), it was determined to be unacceptable during the clinical phase of acceptance testing. High-resolution monitors were evaluated for quality assurance on a weekly basis from installation through acceptance testing and beyond. During clinical utilization determination (CUD), monitor calibration was identified as a problem and the manufacturer returned and recalibrated all workstations. From that time through final acceptance testing, high-resolution monitor calibration and monitor failure rate remained a problem. The monitor vendor then returned to the site to address these areas. Monitor defocus was still noticeable and calibration checks were increased to three times per week. White and black level drift on medium-resolution monitors had been attributed to raster size settings. Measurements of white and black level at several different size settings were taken to determine the effect of size on white and black level settings. Black level remained steady with size change. White level appeared to increase by 2.0 cd/m2 for every 0.1 inches decrease in horizontal raster size. This was determined not to be the cause of the observed brightness drift. Frequency of calibration/testing is an issue in a clinical environment. The increased frequency required at our site cannot be sustained. The medical physics division cannot provide dedicated personnel to conduct the quality-assurance testing on all monitors at this interval due to other physics commitments throughout the hospital. Monitor access is also an issue due to radiologists' need to read images. Some workstations are in use 7 AM

  6. What is a good health check? An interview study of health check providers' views and practices.

    PubMed

    Stol, Yrrah H; Asscher, Eva C A; Schermer, Maartje H N

    2017-10-02

    Health checks identify (risk factors for) disease in people without symptoms. They may be offered by the government through population screenings and by other providers to individual users as 'personal health checks'. Health check providers' perspective of 'good' health checks may further the debate on the ethical evaluation and possible regulation of these personal health checks. In 2015, we interviewed twenty Dutch health check providers on criteria for 'good' health checks, and the role these criteria play in their practices. Providers unanimously formulate a number of minimal criteria: Checks must focus on (risk factors for) treatable/preventable disease; Tests must be reliable and clinically valid; Participation must be informed and voluntary; Checks should provide more benefits than harms; Governmental screenings should be cost-effective. Aspirational criteria mentioned were: Follow-up care should be provided; Providers should be skilled and experienced professionals that put the benefit of (potential) users first; Providers should take time and attention. Some criteria were contested: People should be free to test on any (risk factor for) disease; Health checks should only be performed in people at high risk for disease that are likely to implement health advice; Follow up care of privately funded tests should not drain on collective resources. Providers do not always fulfil their own criteria. Their reasons reveal conflicts between criteria, conflicts between criteria and other ethical values, and point to components in the (Dutch) organisation of health care that hinder an ethical provision of health checks. Moreover, providers consider informed consent a criterion that is hard to establish in practice. According to providers, personal health checks should meet the same criteria as population screenings, with the exception of cost-effectiveness. Providers do not always fulfil their own criteria. Results indicate that in thinking about the ethics of health

  7. General aviation fuel quality control

    NASA Technical Reports Server (NTRS)

    Poitz, H.

    1983-01-01

    Quality control measures for aviation gasoline, and some of the differences between quality control on avgas and mogas are discussed. One thing to keep in mind is that with motor gasoline you can always pull off to the side of the road. It's not so easy to do in an airplane. Consequently, there are reasons for having the tight specifications and the tight quality control measures on avgas as compared to motor gasoline.

  8. Revisiting the Procedures for the Vector Data Quality Assurance in Practice

    NASA Astrophysics Data System (ADS)

    Erdoğan, M.; Torun, A.; Boyacı, D.

    2012-07-01

    of spatial data quality concepts into developments and application requires existence of conceptual, logical and most importantly physical existence of data model, rules and knowledge of realization in a form of geo-spatial data. The applicable metrics and thresholds are determined on this concrete base. This study discusses application of geo-spatial data quality issues and QA (quality assurance) and QC procedures in the topographic data production. Firstly we introduce MGCP (Multinational Geospatial Co-production Program) data profile of NATO (North Atlantic Treaty Organization) DFDD (DGIWG Feature Data Dictionary), the requirements of data owner, the view of data producers for both data capturing and QC and finally QA to fulfil user needs. Then, our practical and new approach which divides the quality into three phases is introduced. Finally, implementation of our approach to accomplish metrics, measures and thresholds of quality definitions is discussed. In this paper, especially geometry and semantics quality and quality control procedures that can be performed by the producers are discussed. Some applicable best-practices that we experienced on techniques of quality control, defining regulations that define the objectives and data production procedures are given in the final remarks. These quality control procedures should include the visual checks over the source data, captured vector data and printouts, some automatic checks that can be performed by software and some semi-automatic checks by the interaction with quality control personnel. Finally, these quality control procedures should ensure the geometric, semantic, attribution and metadata quality of vector data.

  9. Network-based production quality control

    NASA Astrophysics Data System (ADS)

    Kwon, Yongjin; Tseng, Bill; Chiou, Richard

    2007-09-01

    This study investigates the feasibility of remote quality control using a host of advanced automation equipment with Internet accessibility. Recent emphasis on product quality and reduction of waste stems from the dynamic, globalized and customer-driven market, which brings opportunities and threats to companies, depending on the response speed and production strategies. The current trends in industry also include a wide spread of distributed manufacturing systems, where design, production, and management facilities are geographically dispersed. This situation mandates not only the accessibility to remotely located production equipment for monitoring and control, but efficient means of responding to changing environment to counter process variations and diverse customer demands. To compete under such an environment, companies are striving to achieve 100%, sensor-based, automated inspection for zero-defect manufacturing. In this study, the Internet-based quality control scheme is referred to as "E-Quality for Manufacturing" or "EQM" for short. By its definition, EQM refers to a holistic approach to design and to embed efficient quality control functions in the context of network integrated manufacturing systems. Such system let designers located far away from the production facility to monitor, control and adjust the quality inspection processes as production design evolves.

  10. 14 CFR 135.337 - Qualifications: Check airmen (aircraft) and check airmen (simulator).

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... satisfactorily completed the training phases for the aircraft, including recurrent training, that are required to... under this part; (2) Has satisfactorily completed the appropriate training phases for the aircraft... ON BOARD SUCH AIRCRAFT Training § 135.337 Qualifications: Check airmen (aircraft) and check airmen...

  11. Repeal of Comprehensive Background Check Policies and Firearm Homicide and Suicide.

    PubMed

    Kagawa, Rose M C; Castillo-Carniglia, Alvaro; Vernick, Jon S; Webster, Daniel; Crifasi, Cassandra; Rudolph, Kara E; Cerdá, Magdalena; Shev, Aaron; Wintemute, Garen J

    2018-04-02

    In 2016, firearms killed 38,658 people in the United States. Federal law requires licensed gun dealers, but not private parties, to conduct background checks on prospective firearm purchasers with the goal of preventing prohibited persons from obtaining firearms. Our objective was to estimate the effect of the repeal of comprehensive background check laws - requiring a background check for all handgun sales, not just sales by licensed dealers - on firearm homicide and suicide rates in Indiana and Tennessee. We compared age-adjusted firearm homicide and suicide rates, measured annually from 1981-2008 and 1994-2008 in Indiana and Tennessee, respectively, to rates in control groups constructed using the synthetic control method. The average rates of firearm homicide and suicide in Indiana and Tennessee following repeal were within the range of what could be expected given natural variation (differences = 0.7 firearm homicides and 0.5 firearm suicides per 100,000 residents in Indiana and 0.4 firearm homicides and 0.3 firearm suicides per 100,000 residents in Tennessee). Sensitivity analyses resulted in similar findings. We found no evidence of an association between the repeal of comprehensive background check policies and firearm homicide and suicide rates in Indiana and Tennessee. In order to understand whether comprehensive background check policies reduce firearm deaths in the United States generally, more evidence on the impact of such policies from other states is needed.

  12. Data Quality Control for Vessel Mounted Acoustic Doppler Current Profiler. Application for the Western Mediterranean Sea

    NASA Technical Reports Server (NTRS)

    Garcia-Gorriz, E.; Front, J.; Candela, J.

    1997-01-01

    A systematic Data Quality Checking Protocol for vessel Mounted Acoustic Doppler Current Profiler observations is proposed. Previous-to-acquisition conditions are considered along with simultaneous ones.

  13. Effects of a growth check on daily age estimates of age-0 alligator gar

    USGS Publications Warehouse

    Snow, Richard A.; Long, James M.

    2016-01-01

    Accurate age and growth information is essential for a complete knowledge of life history, growth rates, age at sexual maturity, and average life span in fishes. Alligator gar are becoming increasingly managed throughout their range and because this species spawns in backwater flooded areas, their offspring are prone to stranding in areas with limited prey, potentially affecting their growth. Because fish growth is tightly linked with otolith growth and annulus formation, the ability to discern marks not indicative of annuli (age checks) in alligator gar would give managers some insight when estimating ages. Previous studies have suggested that checks are often present prior to the first annulus in otoliths of alligator gar, affecting age estimates. We investigated check formation in otoliths of alligator gar in relation to growth and food availability. Sixteen age-0 alligator gar were marked with oxytetracycline (OTC) to give a reference point and divided equitably into two groups: a control group with abundant prey and an experimental group with limited prey. The experimental group was given 2 g of food per week for 20 days and then given the same prey availability as the control group for the next 20 days. After 40 days, the gar were measured, sacrificed, and their sagittae removed to determine if checks were present. Checks were visible on 14 of the 16 otoliths in the experimental group, associated with low growth during the first 20 days when prey was limited and accelerated growth after prey availability was increased. No checks were observed on otoliths of the control group, where growth and prey availability were consistent. Age estimates of fish in the control group were more accurate than those in the experimental group, showing that fish growth as a function of prey availability likely induced the checks by compressing daily ring formation.

  14. Effectiveness and cost-effectiveness of a very brief physical activity intervention delivered in NHS Health Checks (VBI Trial): study protocol for a randomised controlled trial.

    PubMed

    Mitchell, Joanna; Hardeman, Wendy; Pears, Sally; Vasconcelos, Joana C; Prevost, A Toby; Wilson, Ed; Sutton, Stephen

    2016-06-27

    Physical activity interventions that are targeted at individuals can be effective in encouraging people to be more physically active. However, most such interventions are too long or complex and not scalable to the general population. This trial will test the effectiveness and cost-effectiveness of a very brief physical activity intervention when delivered as part of preventative health checks in primary care (National Health Service (NHS) Health Check). The Very Brief Intervention (VBI) Trial is a two parallel-group, randomised, controlled trial with 1:1 individual allocation and follow-up at 3 months. A total of 1,140 participants will be recruited from 23 primary care practices in the east of England. Participants eligible for an NHS Health Check and who are considered suitable to take part by their doctor and able to provide written informed consent are eligible for the trial. Participants are randomly assigned at the beginning of the NHS Health Check to either 1) the control arm, in which they receive only the NHS Health Check, or 2) the intervention arm, in which they receive the NHS Health Check plus 'Step It Up' (a very brief intervention that can be delivered in 5 minutes by nurses and/or healthcare assistants at the end of the Health Check). 'Step It Up' includes (1) a face-to-face discussion, including feedback on current activity level, recommendations for physical activity, and information on how to use a pedometer, set step goals, and monitor progress; (2) written material supporting the discussion and tips and links to further resources to help increase physical activity; and (3) a pedometer to wear and a step chart for monitoring progress. The primary outcome is accelerometer counts per minute at 3-month follow-up. Secondary outcomes include the time spent in the different levels of physical activity, self-reported physical activity and economic measures. Trial recruitment is underway. The VBI trial will provide evidence on the effectiveness and

  15. 7 CFR 981.42 - Quality control.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Quality control. 981.42 Section 981.42 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Regulating Handling Quality Control § 981.42 Quality control. (a) Incoming. Except as provided in this...

  16. 7 CFR 981.42 - Quality control.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Quality control. 981.42 Section 981.42 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING AGREEMENTS... Regulating Handling Quality Control § 981.42 Quality control. (a) Incoming. Except as provided in this...

  17. 7 CFR 981.42 - Quality control.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Quality control. 981.42 Section 981.42 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Regulating Handling Quality Control § 981.42 Quality control. (a) Incoming. Except as provided in this...

  18. 7 CFR 981.42 - Quality control.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Quality control. 981.42 Section 981.42 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Regulating Handling Quality Control § 981.42 Quality control. (a) Incoming. Except as provided in this...

  19. Intelligent Data Visualization for Cross-Checking Spacecraft System Diagnosis

    NASA Technical Reports Server (NTRS)

    Ong, James C.; Remolina, Emilio; Breeden, David; Stroozas, Brett A.; Mohammed, John L.

    2012-01-01

    Any reasoning system is fallible, so crew members and flight controllers must be able to cross-check automated diagnoses of spacecraft or habitat problems by considering alternate diagnoses and analyzing related evidence. Cross-checking improves diagnostic accuracy because people can apply information processing heuristics, pattern recognition techniques, and reasoning methods that the automated diagnostic system may not possess. Over time, cross-checking also enables crew members to become comfortable with how the diagnostic reasoning system performs, so the system can earn the crew s trust. We developed intelligent data visualization software that helps users cross-check automated diagnoses of system faults more effectively. The user interface displays scrollable arrays of timelines and time-series graphs, which are tightly integrated with an interactive, color-coded system schematic to show important spatial-temporal data patterns. Signal processing and rule-based diagnostic reasoning automatically identify alternate hypotheses and data patterns that support or rebut the original and alternate diagnoses. A color-coded matrix display summarizes the supporting or rebutting evidence for each diagnosis, and a drill-down capability enables crew members to quickly view graphs and timelines of the underlying data. This system demonstrates that modest amounts of diagnostic reasoning, combined with interactive, information-dense data visualizations, can accelerate system diagnosis and cross-checking.

  20. Exercise: When to Check with Your Doctor First

    MedlinePlus

    ... check with your doctor before you start to exercise. By Mayo Clinic Staff Regular exercise can help you control your weight, reduce your ... talk to your doctor before starting a new exercise routine. Although moderate physical activity such as brisk ...

  1. 30 CFR 77.803-2 - Ground check systems not employing pilot check wires; approval by the Secretary.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... wires; approval by the Secretary. 77.803-2 Section 77.803-2 Mineral Resources MINE SAFETY AND HEALTH... check systems not employing pilot check wires; approval by the Secretary. Ground check systems not employing pilot check wires shall be approved by the Secretary only if it is determined that the system...

  2. 30 CFR 77.803-2 - Ground check systems not employing pilot check wires; approval by the Secretary.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... wires; approval by the Secretary. 77.803-2 Section 77.803-2 Mineral Resources MINE SAFETY AND HEALTH... check systems not employing pilot check wires; approval by the Secretary. Ground check systems not employing pilot check wires shall be approved by the Secretary only if it is determined that the system...

  3. 30 CFR 77.803-2 - Ground check systems not employing pilot check wires; approval by the Secretary.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... wires; approval by the Secretary. 77.803-2 Section 77.803-2 Mineral Resources MINE SAFETY AND HEALTH... check systems not employing pilot check wires; approval by the Secretary. Ground check systems not employing pilot check wires shall be approved by the Secretary only if it is determined that the system...

  4. 30 CFR 77.803-2 - Ground check systems not employing pilot check wires; approval by the Secretary.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... wires; approval by the Secretary. 77.803-2 Section 77.803-2 Mineral Resources MINE SAFETY AND HEALTH... check systems not employing pilot check wires; approval by the Secretary. Ground check systems not employing pilot check wires shall be approved by the Secretary only if it is determined that the system...

  5. 30 CFR 77.803-2 - Ground check systems not employing pilot check wires; approval by the Secretary.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... wires; approval by the Secretary. 77.803-2 Section 77.803-2 Mineral Resources MINE SAFETY AND HEALTH... check systems not employing pilot check wires; approval by the Secretary. Ground check systems not employing pilot check wires shall be approved by the Secretary only if it is determined that the system...

  6. 7 CFR 930.44 - Quality control.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Quality control. 930.44 Section 930.44 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Control § 930.44 Quality control. (a) Quality standards. The Board may establish, with the approval of the...

  7. 7 CFR 930.44 - Quality control.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Quality control. 930.44 Section 930.44 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Control § 930.44 Quality control. (a) Quality standards. The Board may establish, with the approval of the...

  8. 7 CFR 930.44 - Quality control.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Quality control. 930.44 Section 930.44 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Control § 930.44 Quality control. (a) Quality standards. The Board may establish, with the approval of the...

  9. 7 CFR 930.44 - Quality control.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Quality control. 930.44 Section 930.44 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING AGREEMENTS... Control § 930.44 Quality control. (a) Quality standards. The Board may establish, with the approval of the...

  10. The method of a joint intraday security check system based on cloud computing

    NASA Astrophysics Data System (ADS)

    Dong, Wei; Feng, Changyou; Zhou, Caiqi; Cai, Zhi; Dan, Xu; Dai, Sai; Zhang, Chuancheng

    2017-01-01

    The intraday security check is the core application in the dispatching control system. The existing security check calculation only uses the dispatch center’s local model and data as the functional margin. This paper introduces the design of all-grid intraday joint security check system based on cloud computing and its implementation. To reduce the effect of subarea bad data on the all-grid security check, a new power flow algorithm basing on comparison and adjustment with inter-provincial tie-line plan is presented. And the numerical example illustrated the effectiveness and feasibility of the proposed method.

  11. A Systematic Review of the Empirical Support for Check-in Check-Out

    ERIC Educational Resources Information Center

    Wolfe, Katie; Pyle, Daniel; Charlton, Cade T.; Sabey, Christian V.; Lund, Emily M.; Ross, Scott W.

    2016-01-01

    Tier 2 interventions play an important role within the Positive Behavioral Interventions and Supports framework, bridging the gap between schoolwide Tier 1 interventions and individualized Tier 3 supports. Check-in Check-out (CICO) is a promising Tier 2 intervention for addressing mild problem behavior and potentially preventing the need for more…

  12. 30 CFR 75.803-2 - Ground check systems not employing pilot check wires; approval by the Secretary.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... wires; approval by the Secretary. 75.803-2 Section 75.803-2 Mineral Resources MINE SAFETY AND HEALTH... Underground High-Voltage Distribution § 75.803-2 Ground check systems not employing pilot check wires; approval by the Secretary. Ground check systems not employing pilot check wires will be approved only if it...

  13. 30 CFR 75.803-2 - Ground check systems not employing pilot check wires; approval by the Secretary.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... wires; approval by the Secretary. 75.803-2 Section 75.803-2 Mineral Resources MINE SAFETY AND HEALTH... Underground High-Voltage Distribution § 75.803-2 Ground check systems not employing pilot check wires; approval by the Secretary. Ground check systems not employing pilot check wires will be approved only if it...

  14. 30 CFR 75.803-2 - Ground check systems not employing pilot check wires; approval by the Secretary.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... wires; approval by the Secretary. 75.803-2 Section 75.803-2 Mineral Resources MINE SAFETY AND HEALTH... Underground High-Voltage Distribution § 75.803-2 Ground check systems not employing pilot check wires; approval by the Secretary. Ground check systems not employing pilot check wires will be approved only if it...

  15. 30 CFR 75.803-2 - Ground check systems not employing pilot check wires; approval by the Secretary.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... wires; approval by the Secretary. 75.803-2 Section 75.803-2 Mineral Resources MINE SAFETY AND HEALTH... Underground High-Voltage Distribution § 75.803-2 Ground check systems not employing pilot check wires; approval by the Secretary. Ground check systems not employing pilot check wires will be approved only if it...

  16. 30 CFR 75.803-2 - Ground check systems not employing pilot check wires; approval by the Secretary.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... wires; approval by the Secretary. 75.803-2 Section 75.803-2 Mineral Resources MINE SAFETY AND HEALTH... Underground High-Voltage Distribution § 75.803-2 Ground check systems not employing pilot check wires; approval by the Secretary. Ground check systems not employing pilot check wires will be approved only if it...

  17. 14 CFR 21.139 - Quality control.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Quality control. 21.139 Section 21.139... PROCEDURES FOR PRODUCTS AND PARTS Production Certificates § 21.139 Quality control. The applicant must show that he has established and can maintain a quality control system for any product, for which he...

  18. 33 CFR 385.21 - Quality control.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 3 2011-07-01 2011-07-01 false Quality control. 385.21 Section... Processes § 385.21 Quality control. (a) The Corps of Engineers and the non-Federal sponsor shall prepare a quality control plan, in accordance with applicable Corps of Engineers regulations, for each product that...

  19. 14 CFR 21.139 - Quality control.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Quality control. 21.139 Section 21.139... PROCEDURES FOR PRODUCTS AND PARTS Production Certificates § 21.139 Quality control. The applicant must show that he has established and can maintain a quality control system for any product, for which he...

  20. 33 CFR 385.21 - Quality control.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 3 2013-07-01 2013-07-01 false Quality control. 385.21 Section... Processes § 385.21 Quality control. (a) The Corps of Engineers and the non-Federal sponsor shall prepare a quality control plan, in accordance with applicable Corps of Engineers regulations, for each product that...

  1. 33 CFR 385.21 - Quality control.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Quality control. 385.21 Section... Processes § 385.21 Quality control. (a) The Corps of Engineers and the non-Federal sponsor shall prepare a quality control plan, in accordance with applicable Corps of Engineers regulations, for each product that...

  2. Quality monitored distributed voting system

    DOEpatents

    Skogmo, David

    1997-01-01

    A quality monitoring system can detect certain system faults and fraud attempts in a distributed voting system. The system uses decoy voters to cast predetermined check ballots. Absent check ballots can indicate system faults. Altered check ballots can indicate attempts at counterfeiting votes. The system can also cast check ballots at predetermined times to provide another check on the distributed voting system.

  3. 40 CFR 136.7 - Quality assurance and quality control.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... quality control elements, where applicable, into the laboratory's documented standard operating procedure... quality control elements must be clearly documented in the written standard operating procedure for each... Methods contains QA/QC procedures in the Part 1000 section of the Standard Methods Compendium. The...

  4. 40 CFR 136.7 - Quality assurance and quality control.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... quality control elements, where applicable, into the laboratory's documented standard operating procedure... quality control elements must be clearly documented in the written standard operating procedure for each... Methods contains QA/QC procedures in the Part 1000 section of the Standard Methods Compendium. The...

  5. 40 CFR 136.7 - Quality assurance and quality control.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... quality control elements, where applicable, into the laboratory's documented standard operating procedure... quality control elements must be clearly documented in the written standard operating procedure for each... Methods contains QA/QC procedures in the Part 1000 section of the Standard Methods Compendium. The...

  6. Geomorphological and ecological effects of check dams in mountain torrents of Southern Italy

    NASA Astrophysics Data System (ADS)

    Zema, Demetrio Antonio; Bombino, Giuseppe; Denisi, Pietro; Tamburino, Vincenzo; Marcello Zimbone, Santo

    2017-04-01

    It is known that installation of check dams noticeably influences torrent morphology and ecology. However, the effects of check dams on channel section and riparian vegetation of torrents are not yet completely understood. This paper provides a further contribution to a better comprehension of the actions played by check dams on hydrological and geomorphological processes in headwaters and their effects on riparian ecosystem. Field surveys on channel morphology, bed material and riparian vegetation were carried out close to five check dams in each of four mountain reaches of Calabria (Southern Italy). For each check dam three transects (one upstream, one downstream and one far from the check dam, located in the undisturbed zone and adopted as control) were identified; at each transect, a set of geomorphological and ecological indicators were surveyed as follows. Channel section morphology was assessed by the width/depth ratio (w/d); the median particle size (D50) and the finer sediment fraction (%fines) were chosen to characterize channel bed material; the specific discharge (q, the discharge per channel unit width) was assumed as measure of the flow regime. Vegetation cover and structure were evaluated by Global Canopy Cover (GCC) and Weighted Canopy Height (WCH) respectively (Bombino et al., 2008); the index of alpha-diversity (H-alpha, Hill, 1973) and the ratio between the number of alien species and the number of native species (NSA/NSN) were chosen as indicators of species richness/abundance and degree of vegetation integrity, respectively. Compared to the control transects, the values of w/d were higher upstream of check dams and lower downstream; conversely, q was lower upstream and higher in downstream sites. Upstream of the check dams D50 of bed material was lower and %fines was higher compared to the control transects; vice versa, the downstream transects showed higher D50 and lower %fines. The differences in the riparian vegetation among transects were

  7. 14 CFR 91.1089 - Qualifications: Check pilots (aircraft) and check pilots (simulator).

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... simulator, or in a flight training device for a particular type aircraft. (2) A check pilot (simulator) is a person who is qualified to conduct flight checks, but only in a flight simulator, in a flight training... (simulator) must accomplish the following— (1) Fly at least two flight segments as a required crewmember for...

  8. 14 CFR 91.1089 - Qualifications: Check pilots (aircraft) and check pilots (simulator).

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... simulator, or in a flight training device for a particular type aircraft. (2) A check pilot (simulator) is a person who is qualified to conduct flight checks, but only in a flight simulator, in a flight training... (simulator) must accomplish the following— (1) Fly at least two flight segments as a required crewmember for...

  9. 14 CFR 91.1089 - Qualifications: Check pilots (aircraft) and check pilots (simulator).

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... simulator, or in a flight training device for a particular type aircraft. (2) A check pilot (simulator) is a person who is qualified to conduct flight checks, but only in a flight simulator, in a flight training... (simulator) must accomplish the following— (1) Fly at least two flight segments as a required crewmember for...

  10. Population-based cancer survival in the United States: Data, quality control, and statistical methods.

    PubMed

    Allemani, Claudia; Harewood, Rhea; Johnson, Christopher J; Carreira, Helena; Spika, Devon; Bonaventure, Audrey; Ward, Kevin; Weir, Hannah K; Coleman, Michel P

    2017-12-15

    Robust comparisons of population-based cancer survival estimates require tight adherence to the study protocol, standardized quality control, appropriate life tables of background mortality, and centralized analysis. The CONCORD program established worldwide surveillance of population-based cancer survival in 2015, analyzing individual data on 26 million patients (including 10 million US patients) diagnosed between 1995 and 2009 with 1 of 10 common malignancies. In this Cancer supplement, we analyzed data from 37 state cancer registries that participated in the second cycle of the CONCORD program (CONCORD-2), covering approximately 80% of the US population. Data quality checks were performed in 3 consecutive phases: protocol adherence, exclusions, and editorial checks. One-, 3-, and 5-year age-standardized net survival was estimated using the Pohar Perme estimator and state- and race-specific life tables of all-cause mortality for each year. The cohort approach was adopted for patients diagnosed between 2001 and 2003, and the complete approach for patients diagnosed between 2004 and 2009. Articles in this supplement report population coverage, data quality indicators, and age-standardized 5-year net survival by state, race, and stage at diagnosis. Examples of tables, bar charts, and funnel plots are provided in this article. Population-based cancer survival is a key measure of the overall effectiveness of services in providing equitable health care. The high quality of US cancer registry data, 80% population coverage, and use of an unbiased net survival estimator ensure that the survival trends reported in this supplement are robustly comparable by race and state. The results can be used by policymakers to identify and address inequities in cancer survival in each state and for the United States nationally. Cancer 2017;123:4982-93. Published 2017. This article is a U.S. Government work and is in the public domain in the USA. Published 2017. This article is a U

  11. Data quality in a DRG-based information system.

    PubMed

    Colin, C; Ecochard, R; Delahaye, F; Landrivon, G; Messy, P; Morgon, E; Matillon, Y

    1994-09-01

    The aim of this study initiated in May 1990 was to evaluate the quality of the medical data collected from the main hospital of the "Hospices Civils de Lyon", Edouard Herriot Hospital. We studied a random sample of 593 discharge abstracts from 12 wards of the hospital. Quality control was performed by checking multi-hospitalized patients' personal data, checking that each discharge abstract was exhaustive, examining the quality of abstracting, studying diagnoses and medical procedures coding, and checking data entry. Assessment of personal data showed a 4.4% error rate. It was mainly accounted for by spelling mistakes in surnames and first names, and mistakes in dates of birth. The quality of a discharge abstract was estimated according to the two purposes of the medical information system: description of hospital morbidity per patient and Diagnosis Related Group's case mix. Error rates in discharge abstracts were expressed in two ways: an overall rate for errors of concordance between Discharge Abstracts and Medical Records, and a specific rate for errors modifying classification in Diagnosis Related Groups (DRG). For abstracting medical information, these error rates were 11.5% (SE +/- 2.2) and 7.5% (SE +/- 1.9) respectively. For coding diagnoses and procedures, they were 11.4% (SE +/- 1.5) and 1.3% (SE +/- 0.5) respectively. For data entry on the computerized data base, the error rate was 2% (SE +/- 0.5) and 0.2% (SE +/- 0.05). Quality control must be performed regularly because it demonstrates the degree of participation from health care teams and the coherence of the database.(ABSTRACT TRUNCATED AT 250 WORDS)

  12. Effects of monetary reward and punishment on information checking behaviour.

    PubMed

    Li, Simon Y W; Cox, Anna L; Or, Calvin; Blandford, Ann

    2016-03-01

    Two experiments were conducted to examine whether checking one's own work can be motivated by monetary reward and punishment. Participants were randomly assigned to one of three conditions: a flat-rate payment for completing the task (Control); payment increased for error-free performance (Reward); payment decreased for error performance (Punishment). Experiment 1 (N = 90) was conducted with liberal arts students, using a general data-entry task. Experiment 2 (N = 90) replicated Experiment 1 with clinical students and a safety-critical 'cover story' for the task. In both studies, Reward and Punishment resulted in significantly fewer errors, more frequent and longer checking, than Control. No such differences were obtained between the Reward and Punishment conditions. It is concluded that error consequences in terms of monetary reward and punishment can result in more accurate task performance and more rigorous checking behaviour than errors without consequences. However, whether punishment is more effective than reward, or vice versa, remains inconclusive. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  13. Quality monitored distributed voting system

    DOEpatents

    Skogmo, D.

    1997-03-18

    A quality monitoring system can detect certain system faults and fraud attempts in a distributed voting system. The system uses decoy voters to cast predetermined check ballots. Absent check ballots can indicate system faults. Altered check ballots can indicate attempts at counterfeiting votes. The system can also cast check ballots at predetermined times to provide another check on the distributed voting system. 6 figs.

  14. Property Differencing for Incremental Checking

    NASA Technical Reports Server (NTRS)

    Yang, Guowei; Khurshid, Sarfraz; Person, Suzette; Rungta, Neha

    2014-01-01

    This paper introduces iProperty, a novel approach that facilitates incremental checking of programs based on a property di erencing technique. Speci cally, iProperty aims to reduce the cost of checking properties as they are initially developed and as they co-evolve with the program. The key novelty of iProperty is to compute the di erences between the new and old versions of expected properties to reduce the number and size of the properties that need to be checked during the initial development of the properties. Furthermore, property di erencing is used in synergy with program behavior di erencing techniques to optimize common regression scenarios, such as detecting regression errors or checking feature additions for conformance to new expected properties. Experimental results in the context of symbolic execution of Java programs annotated with properties written as assertions show the e ectiveness of iProperty in utilizing change information to enable more ecient checking.

  15. QUALITY CONTROL OF PHARMACEUTICALS.

    PubMed

    LEVI, L; WALKER, G C; PUGSLEY, L I

    1964-10-10

    Quality control is an essential operation of the pharmaceutical industry. Drugs must be marketed as safe and therapeutically active formulations whose performance is consistent and predictable. New and better medicinal agents are being produced at an accelerated rate. At the same time more exacting and sophisticated analytical methods are being developed for their evaluation. Requirements governing the quality control of pharmaceuticals in accordance with the Canadian Food and Drugs Act are cited and discussed.

  16. The Quality Control Algorithms Used in the Creation of NASA Kennedy Space Center Lightning Protection System Towers Meteorological Database

    NASA Technical Reports Server (NTRS)

    Orcutt, John M.; Brenton, James C.

    2016-01-01

    An accurate database of meteorological data is essential for designing any aerospace vehicle and for preparing launch commit criteria. Meteorological instrumentation were recently placed on the three Lightning Protection System (LPS) towers at Kennedy Space Center (KSC) launch complex 39B (LC-39B), which provide a unique meteorological dataset existing at the launch complex over an extensive altitude range. Data records of temperature, dew point, relative humidity, wind speed, and wind direction are produced at 40, 78, 116, and 139 m at each tower. The Marshall Space Flight Center Natural Environments Branch (EV44) received an archive that consists of one-minute averaged measurements for the period of record of January 2011 - April 2015. However, before the received database could be used EV44 needed to remove any erroneous data from within the database through a comprehensive quality control (QC) process. The QC process applied to the LPS towers' meteorological data is similar to other QC processes developed by EV44, which were used in the creation of meteorological databases for other towers at KSC. The QC process utilized in this study has been modified specifically for use with the LPS tower database. The QC process first includes a check of each individual sensor. This check includes removing any unrealistic data and checking the temporal consistency of each variable. Next, data from all three sensors at each height are checked against each other, checked against climatology, and checked for sensors that erroneously report a constant value. Then, a vertical consistency check of each variable at each tower is completed. Last, the upwind sensor at each level is selected to minimize the influence of the towers and other structures at LC-39B on the measurements. The selection process for the upwind sensor implemented a study of tower-induced turbulence. This paper describes in detail the QC process, QC results, and the attributes of the LPS towers meteorological

  17. Judicial Checks and Balances

    ERIC Educational Resources Information Center

    La Porta, Rafael; Lopez-de-Silanes, Florencio; Pop-Eleches, Cristian; Shleifer, Andrei

    2004-01-01

    In the Anglo-American constitutional tradition, judicial checks and balances are often seen as crucial guarantees of freedom. Hayek distinguishes two ways in which the judiciary provides such checks and balances: judicial independence and constitutional review. We create a new database of constitutional rules in 71 countries that reflect these…

  18. 7 CFR 58.928 - Quality control tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Quality control tests. 58.928 Section 58.928... Procedures § 58.928 Quality control tests. All dairy products and other ingredients shall be subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be...

  19. Expert database system for quality control

    NASA Astrophysics Data System (ADS)

    Wang, Anne J.; Li, Zhi-Cheng

    1993-09-01

    There are more competitors today. Markets are not homogeneous they are fragmented into increasingly focused niches requiring greater flexibility in the product mix shorter manufacturing production runs and above allhigher quality. In this paper the author identified a real-time expert system as a way to improve plantwide quality management. The quality control expert database system (QCEDS) by integrating knowledge of experts in operations quality management and computer systems use all information relevant to quality managementfacts as well as rulesto determine if a product meets quality standards. Keywords: expert system quality control data base

  20. A novel cognitive intervention for compulsive checking: Targeting maladaptive beliefs about memory.

    PubMed

    Alcolado, Gillian M; Radomsky, Adam S

    2016-12-01

    Compulsive checking is one of the most common symptoms of obsessive-compulsive disorder (OCD). Recently it has been proposed that those who check compulsively may believe their memory is poor, rather than having an actual memory impairment. The current study sought to develop and assess a brief cognitive intervention focused on improving maladaptive beliefs about memory, as they pertain to both checking symptoms and memory performance. Participants (N = 24) with a diagnosis of OCD and clinical levels of checking symptomatology were randomly assigned either to receive two weekly 1-hour therapy sessions or to self-monitor during a similar waitlist period. Time spent checking, checking symptoms, maladaptive beliefs about memory, and visuospatial memory were assessed both pre- and post-treatment/waitlist. Results showed that compared to the waitlist condition, individuals in the treatment condition displayed significant decreases in their maladaptive beliefs about memory and checking symptoms from pre- to post-intervention. They also exhibited increased recall performance on a measure of visuospatial memory. Changes in beliefs about memory were predictors of reduced post-intervention checking, but were not predictive of increased post-intervention memory scores. The lack of long term follow-up data and use of a waitlist control leave questions about the stability and specificity of the intervention. Findings provide preliminary evidence that strategies targeting beliefs about memory may be worthy of inclusion in cognitive-behavioural approaches to treating compulsive checking. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. 7 CFR 58.335 - Quality control tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Quality control tests. 58.335 Section 58.335... Procedures § 58.335 Quality control tests. All milk, cream and related products are subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be made on flow...

  2. [Design and implementation of data checking system for Chinese materia medica resources survey].

    PubMed

    Wang, Hui; Zhang, Xiao-Bo; Ge, Xiao-Guang; Jin, Yan; Jing, Zhi-Xian; Qi, Yuan-Hua; Wang, Ling; Zhao, Yu-Ping; Wang, Wei; Guo, Lan-Ping; Huang, Lu-Qi

    2017-11-01

    The Chinese material medica resources (CMMR) national survey information management system has collected a large amount of data. To help dealing with data recheck, reduce the work of inside, improve the recheck of survey data from provincial and county level, National Resource Center for Chinese Materia Medical has designed a data checking system for Chinese material medica resources survey based on J2EE technology, Java language, Oracle data base in accordance with the SOA framework. It includes single data check, check score, content manage, check the survey data census data with manual checking and automatic checking about census implementation plan, key research information, general survey information, cultivation of medicinal materials information, germplasm resources information the medicine information, market research information, traditional knowledge information, specimen information of this 9 aspects 20 class 175 indicators in two aspects of the quantity and quality. The established system assists in the completion of the data consistency and accuracy, pushes the county survey team timely to complete the data entry arrangement work, so as to improve the integrity, consistency and accuracy of the survey data, and ensure effective and available data, which lay a foundation for providing accurate data support for national survey of the Chinese material medica resources (CMMR) results summary, and displaying results and sharing. Copyright© by the Chinese Pharmaceutical Association.

  3. Model Checking Satellite Operational Procedures

    NASA Astrophysics Data System (ADS)

    Cavaliere, Federico; Mari, Federico; Melatti, Igor; Minei, Giovanni; Salvo, Ivano; Tronci, Enrico; Verzino, Giovanni; Yushtein, Yuri

    2011-08-01

    We present a model checking approach for the automatic verification of satellite operational procedures (OPs). Building a model for a complex system as a satellite is a hard task. We overcome this obstruction by using a suitable simulator (SIMSAT) for the satellite. Our approach aims at improving OP quality assurance by automatic exhaustive exploration of all possible simulation scenarios. Moreover, our solution decreases OP verification costs by using a model checker (CMurphi) to automatically drive the simulator. We model OPs as user-executed programs observing the simulator telemetries and sending telecommands to the simulator. In order to assess feasibility of our approach we present experimental results on a simple meaningful scenario. Our results show that we can save up to 90% of verification time.

  4. Quality Control of Pharmaceuticals

    PubMed Central

    Levi, Leo; Walker, George C.; Pugsley, L. I.

    1964-01-01

    Quality control is an essential operation of the pharmaceutical industry. Drugs must be marketed as safe and therapeutically active formulations whose performance is consistent and predictable. New and better medicinal agents are being produced at an accelerated rate. At the same time more exacting and sophisticated analytical methods are being developed for their evaluation. Requirements governing the quality control of pharmaceuticals in accordance with the Canadian Food and Drugs Act are cited and discussed. PMID:14199105

  5. Comprehensive HPTLC Fingerprinting for Quality Control of an Herbal Drug - The Case of Angelica gigas Root.

    PubMed

    Frommenwiler, Débora Arruda; Kim, Jonghwan; Yook, Chang-Soo; Tran, Thi Thu Trang; Cañigueral, Salvador; Reich, Eike

    2018-04-01

    The quality of herbal drugs is usually controlled using several tests recommended in a monograph. HPTLC is the method of choice for identification in many pharmacopoeias. If combined with a suitable reference material for comparison, HPTLC can provide information beyond identification and thus may simplify quality control. This paper describes, as a proof of concept, how HPTLC can be applied to define specifications for an herbal reference material and to control the quality of an herbal drug according to these specifications. Based on multiple batches of cultivated Angelica gigas root, a specific HPTLC method for identification was optimized. This method can distinguish 27 related species. It also can detect the presence of mixtures of A. gigas with two other Angelica species traded as "Dang gui" and is suitable as well for quantitative assessment of samples in a test for minimum content of the sum of decursin and decursinol angelate. The new concept of "comprehensive HPTLC fingerprinting" is proposed: HPTLC fingerprints (images), which are used for identification, are converted into peak profiles and the intensities of selected zones are quantitatively compared to those of the corresponding zones of the reference material. Following a collaborative trial involving three laboratories in three countries, the method was applied to check the quality of further candidates for establishing an appropriate reference material. In conclusion, this case demonstrates that a single HPTLC analysis can provide information about identity, purity, and minimum content of markers of an herbal drug. Georg Thieme Verlag KG Stuttgart · New York.

  6. 30 CFR 28.31 - Quality control plans; contents.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality control plans; contents. 28.31 Section... PROTECTION FOR TRAILING CABLES IN COAL MINES Quality Control § 28.31 Quality control plans; contents. (a) Each quality control plan shall contain provisions for the management of quality, including: (1...

  7. [Highly quality-controlled radiation therapy].

    PubMed

    Shirato, Hiroki

    2005-04-01

    Advanced radiation therapy for intracranial disease has focused on set-up accuracy for the past 15 years. However, quality control in the prescribed dose is actually as important as the tumor set-up in radiation therapy. Because of the complexity of the three-dimensional radiation treatment planning system in recent years, the highly quality-controlled prescription of the dose has now been reappraised as the mainstream to improve the treatment outcome of radiation therapy for intracranial disease. The Japanese Committee for Quality Control of Radiation Therapy has developed fundamental requirements such as a QC committee in each hospital, a medical physicist, dosimetrists (QC members), and an external audit.

  8. Control by quality: proposition of a typology.

    PubMed

    Pujo, P; Pillet, M

    The application of Quality tools and methods in industrial management has always had a fundamental impact on the control of production. It influences the behavior of the actors concerned, while introducing the necessary notions and formalizations, especially for production systems with little or no automation, which constitute a large part of the industrial activity. Several quality approaches are applied in the workshop and are implemented at the level of the control. In this paper, the authors present a typology of the various approaches that have successively influenced control, such as statistical process control, quality assurance, and continuous improvement. First the authors present a parallel between production control and quality organizational structure. They note the duality between control, which is aimed at increasing productivity, and quality, which aims to satisfy the needs of the customer. They also note the hierarchical organizational structure of these two systems of management with, at each level, the notion of a feedback loop. This notion is fundamental to any kind of decision making. The paper is organized around the operational, tactical, and strategic levels, by describing for each level the main methods and tools for control by quality. The overview of these tools and methods starts at the operational level, with the Statistical Process Control, the Taguchi technique, and the "six sigma" approach. On the tactical level, we find a quality system approach, with a documented description of the procedures introduced in the firm. The management system can refer here to Quality Assurance, Total Productive Maintenance, or Management by Total Quality. The formalization through procedures of the rules of decision governing the process control enhances the validity of these rules. This leads to the enhancement of their reliability and to their consolidation. All this counterbalances the human, intrinsically fluctuating, behavior of the control

  9. Function-Based Modification of Check-In/Check-Out to Influence Escape-Maintained Behavior

    ERIC Educational Resources Information Center

    Kilgus, Stephen P.; Fallon, Lindsay M.; Feinberg, Adam B.

    2016-01-01

    Prior research has suggested Check-In/Check-Out (CICO) effectiveness is linked to the function of problem behavior. Though effective for students whose misbehavior occurs to gain attention, findings are equivocal for behavior that occurs to escape academic tasks. The purpose of this study was to therefore evaluate a modification to CICO, wherein…

  10. Quantitative assessment of locomotive syndrome by the loco-check questionnaire in older Japanese females

    PubMed Central

    Noge, Sachiko; Ohishi, Tatsuo; Yoshida, Takuya; Kumagai, Hiromichi

    2017-01-01

    [Purpose] Locomotive syndrome (LS) is a condition by which older people may require care service because of problems with locomotive organs. This study examined whether the loco-check, a 7-item questionnaire, is useful for quantitatively assessing the severity of LS. [Subjects and Methods] Seventy-one community dwelling Japanese females aged 64–96 years (81.7 ± 8.0 years) participated in this study. The associations of the loco-check with thigh muscle mass measured by X-ray CT, physical performance, nutritional status, and quality of life (QOL) were investigated. [Results] The results showed that the number of times that “yes” was selected in the loco-check was significantly correlated with thigh muscle mass, major measures of physical performance, nutritional status, and QOL. This number was also significantly larger in the participants experiencing falling, fracture, and lumbar pain than in those without these episodes. [Conclusion] These results suggest that the loco-check might be useful for quantitatively evaluating LS. PMID:28932003

  11. Quality control system preparation for photogrammetric and laser scanning missions of Spanish national plan of aerial orthophotogpaphy (PNOA). (Polish Title: Opracowanie systemu kontroli jakości realizacji nalotów fotogrametrycznych i skaningowych dla hiszpańskiego narodowego planu ortofotomapy lotniczej (PNOA))

    NASA Astrophysics Data System (ADS)

    Rzonca, A.

    2013-12-01

    The paper presents the state of the art of quality control of photogrammetric and laser scanning data captured by airborne sensors. The described subject is very important for photogrammetric and LiDAR project execution, because the data quality a prior decides about the final product quality. On the other hand, precise and effective quality control process allows to execute the missions without wide margin of safety, especially in case of the mountain areas projects. For introduction, the author presents theoretical background of the quality control, basing on his own experience, instructions and technical documentation. He describes several variants of organization solutions. Basically, there are two main approaches: quality control of the captured data and the control of discrepancies of the flight plan and its results of its execution. Both of them are able to use test of control and analysis of the data. The test is an automatic algorithm controlling the data and generating the control report. Analysis is a less complicated process, that is based on documentation, data and metadata manual check. The example of quality control system for large area project was presented. The project is being realized periodically for the territory of all Spain and named National Plan of Aerial Orthophotography (Plan Nacional de Ortofotografía Aérea, PNOA). The system of the internal control guarantees its results soon after the flight and informs the flight team of the company. It allows to correct all the errors shortly after the flight and it might stop transferring the data to another team or company, for further data processing. The described system of data quality control contains geometrical and radiometrical control of photogrammetric data and geometrical control of LiDAR data. According to all specified parameters, it checks all of them and generates the reports. They are very helpful in case of some errors or low quality data. The paper includes the author experience

  12. 30 CFR 74.6 - Quality control.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Quality control. 74.6 Section 74.6 Mineral... of the CMDPSU will be maintained in production through adequate quality control procedures, MSHA and... DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust Personal Sampler Unit § 74.6 Quality...

  13. Child Care: State Requirements for Background Checks.

    ERIC Educational Resources Information Center

    Fagnoni, Cynthia

    Background checks involve gathering information from state and federal databases to determine if child care providers have a history of child abuse or other criminal convictions that would make them unacceptable for working with children. Background checks include state criminal history checks, state child abuse registry checks, and Federal Bureau…

  14. [Pre-verbality in focusing and the need for self check. An attempt at "focusing check"].

    PubMed

    Masui, T; Ikemi, A; Murayama, S

    1983-06-01

    Though the Focusing process is not entirely non-verbal, in Focusing, careful attention is paid by the Focuser and the Listener to the pre-verbal experiential process. In other words, Focusing involves attending to the felt sense that is not easily expressed in words immediately. Hence, during the process of learning to Focus, the Focusing teacher attempts to communicate the experiences of Focusing to the student which are not easily done by words. Due to such difficulties, the Focusing student may (and quite frequently does) mistake the experiential process in Focusing with other processes. Often, the felt sense can be confused with other phenomena such as "autogenic discharge". Also the Focuser may not stay with the felt sense and drift into "free association" or frequently, certain processes in "meditation" can be confused with Focusing. Therefore, there is a need for a "check" by which the Focusing student can confirm the Focusing experience for himself. For the Focusing student, such a "check" serves not only to confirm the Focusing process, but also an aid to learning Focusing. We will report here a "Focusing Check" which we developed by translating Eugene Gendlin's "Focusing Check" and making several modifications in it so that it will be more understandable to the Japanese. Along with the "Focusing Check" we developed, the authors discuss the need for such a check.

  15. Distributed sensor architecture for intelligent control that supports quality of control and quality of service.

    PubMed

    Poza-Lujan, Jose-Luis; Posadas-Yagüe, Juan-Luis; Simó-Ten, José-Enrique; Simarro, Raúl; Benet, Ginés

    2015-02-25

    This paper is part of a study of intelligent architectures for distributed control and communications systems. The study focuses on optimizing control systems by evaluating the performance of middleware through quality of service (QoS) parameters and the optimization of control using Quality of Control (QoC) parameters. The main aim of this work is to study, design, develop, and evaluate a distributed control architecture based on the Data-Distribution Service for Real-Time Systems (DDS) communication standard as proposed by the Object Management Group (OMG). As a result of the study, an architecture called Frame-Sensor-Adapter to Control (FSACtrl) has been developed. FSACtrl provides a model to implement an intelligent distributed Event-Based Control (EBC) system with support to measure QoS and QoC parameters. The novelty consists of using, simultaneously, the measured QoS and QoC parameters to make decisions about the control action with a new method called Event Based Quality Integral Cycle. To validate the architecture, the first five Braitenberg vehicles have been implemented using the FSACtrl architecture. The experimental outcomes, demonstrate the convenience of using jointly QoS and QoC parameters in distributed control systems.

  16. Distributed Sensor Architecture for Intelligent Control that Supports Quality of Control and Quality of Service

    PubMed Central

    Poza-Lujan, Jose-Luis; Posadas-Yagüe, Juan-Luis; Simó-Ten, José-Enrique; Simarro, Raúl; Benet, Ginés

    2015-01-01

    This paper is part of a study of intelligent architectures for distributed control and communications systems. The study focuses on optimizing control systems by evaluating the performance of middleware through quality of service (QoS) parameters and the optimization of control using Quality of Control (QoC) parameters. The main aim of this work is to study, design, develop, and evaluate a distributed control architecture based on the Data-Distribution Service for Real-Time Systems (DDS) communication standard as proposed by the Object Management Group (OMG). As a result of the study, an architecture called Frame-Sensor-Adapter to Control (FSACtrl) has been developed. FSACtrl provides a model to implement an intelligent distributed Event-Based Control (EBC) system with support to measure QoS and QoC parameters. The novelty consists of using, simultaneously, the measured QoS and QoC parameters to make decisions about the control action with a new method called Event Based Quality Integral Cycle. To validate the architecture, the first five Braitenberg vehicles have been implemented using the FSACtrl architecture. The experimental outcomes, demonstrate the convenience of using jointly QoS and QoC parameters in distributed control systems. PMID:25723145

  17. Quality control education in the community college

    NASA Technical Reports Server (NTRS)

    Greene, J. Griffen; Wilson, Steve

    1966-01-01

    This paper describes the Quality Control Program at Daytona Beach Junior College, including course descriptions. The program in quality control required communication between the college and the American Society for Quality Control (ASQC). The college has machinery established for certification of the learning process, and the society has the source of teachers who are competent in the technical field and who are the employers of the educational products. The associate degree for quality control does not have a fixed program, which can serve all needs, any more than all engineering degrees have identical programs. The main ideas which would be common to all quality control programs are the concept of economic control of a repetitive process and the concept of developing individual potentialities into individuals who are needed and productive.

  18. 48 CFR 352.237-72 - Crime Control Act-requirement for background checks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... of 1990 (Act), requires that all individuals involved with the provision of child care services to children under the age of 18 undergo a criminal background check. “Child care services” include, but are not limited to, social services, health and mental health care, child (day) care, education (whether...

  19. 48 CFR 352.237-72 - Crime Control Act-requirement for background checks.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... of 1990 (Act), requires that all individuals involved with the provision of child care services to children under the age of 18 undergo a criminal background check. “Child care services” include, but are not limited to, social services, health and mental health care, child (day) care, education (whether...

  20. 48 CFR 352.237-72 - Crime Control Act-requirement for background checks.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... of 1990 (Act), requires that all individuals involved with the provision of child care services to children under the age of 18 undergo a criminal background check. “Child care services” include, but are not limited to, social services, health and mental health care, child (day) care, education (whether...

  1. 48 CFR 352.237-72 - Crime Control Act-requirement for background checks.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... of 1990 (Act), requires that all individuals involved with the provision of child care services to children under the age of 18 undergo a criminal background check. “Child care services” include, but are not limited to, social services, health and mental health care, child (day) care, education (whether...

  2. 48 CFR 352.237-72 - Crime Control Act-requirement for background checks.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... of 1990 (Act), requires that all individuals involved with the provision of child care services to children under the age of 18 undergo a criminal background check. “Child care services” include, but are not limited to, social services, health and mental health care, child (day) care, education (whether...

  3. The influence of lathe check depth and orientation on the bond quality of phenol-formaldehyde-bonded birch plywood

    Treesearch

    Anti Rohumaa; Christopher G. Hunt; Mark Hughes; Charles R. Frihart; Janne Logren

    2013-01-01

    During the rotary peeling of veneer for plywood or the laminated veneer lumber manufacture, checks are formed in the veneer that are as deep as 70 – 80 % of the veneer thickness. The results of this study show that, during adhesive bond testing, deep lathe checks in birch (Betula pendula Roth.) veneer significantly reduce the shear strength and the...

  4. Common Sense or Gun Control? Political Communication and News Media Framing of Firearm Sale Background Checks after Newtown.

    PubMed

    McGinty, Emma E; Wolfson, Julia A; Sell, Tara Kirk; Webster, Daniel W

    2016-02-01

    Gun violence is a critical public health problem in the United States, but it is rarely at the top of the public policy agenda. The 2012 mass shooting in Newtown, Connecticut, opened a rare window of opportunity to strengthen firearm policies in the United States. In this study, we examine the American public's exposure to competing arguments for and against federal- and state-level universal background check laws, which would require a background check prior to every firearm sale, in a large sample of national and regional news stories (n = 486) published in the year following the Newtown shooting. Competing messages about background check laws could influence the outcome of policy debates by shifting support and political engagement among key constituencies such as gun owners and conservatives. We found that news media messages in support of universal background checks were fact-based and used rational arguments, and opposing messages often used rights-based frames designed to activate the core values of politically engaged gun owners. Reframing supportive messages about background check policies to align with gun owners' and conservatives' core values could be a promising strategy to increase these groups' willingness to vocalize their support for expanding background checks for firearm sales. Copyright © 2016 by Duke University Press.

  5. Immediate Effects of Body Checking Behaviour on Negative and Positive Emotions in Women with Eating Disorders: An Ecological Momentary Assessment Approach.

    PubMed

    Kraus, Nicole; Lindenberg, Julia; Zeeck, Almut; Kosfelder, Joachim; Vocks, Silja

    2015-09-01

    Cognitive-behavioural models of eating disorders state that body checking arises in response to negative emotions in order to reduce the aversive emotional state and is therefore negatively reinforced. This study empirically tests this assumption. For a seven-day period, women with eating disorders (n = 26) and healthy controls (n = 29) were provided with a handheld computer for assessing occurring body checking strategies as well as negative and positive emotions. Serving as control condition, randomized computer-emitted acoustic signals prompted reports on body checking and emotions. There was no difference in the intensity of negative emotions before body checking and in control situations across groups. However, from pre- to post-body checking, an increase in negative emotions was found. This effect was more pronounced in women with eating disorders compared with healthy controls. Results are contradictory to the assumptions of the cognitive-behavioural model, as body checking does not seem to reduce negative emotions. Copyright © 2015 John Wiley & Sons, Ltd and Eating Disorders Association.

  6. Program Model Checking: A Practitioner's Guide

    NASA Technical Reports Server (NTRS)

    Pressburger, Thomas T.; Mansouri-Samani, Masoud; Mehlitz, Peter C.; Pasareanu, Corina S.; Markosian, Lawrence Z.; Penix, John J.; Brat, Guillaume P.; Visser, Willem C.

    2008-01-01

    Program model checking is a verification technology that uses state-space exploration to evaluate large numbers of potential program executions. Program model checking provides improved coverage over testing by systematically evaluating all possible test inputs and all possible interleavings of threads in a multithreaded system. Model-checking algorithms use several classes of optimizations to reduce the time and memory requirements for analysis, as well as heuristics for meaningful analysis of partial areas of the state space Our goal in this guidebook is to assemble, distill, and demonstrate emerging best practices for applying program model checking. We offer it as a starting point and introduction for those who want to apply model checking to software verification and validation. The guidebook will not discuss any specific tool in great detail, but we provide references for specific tools.

  7. 23 CFR 1340.8 - Quality control.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... OBSERVATIONAL SURVEYS OF SEAT BELT USE Survey Design Requirements § 1340.8 Quality control. (a) Quality control... control monitors involved in seat belt use surveys shall have received training in data collection...) Statistical review. Survey results shall be reviewed and approved by a survey statistician, i.e., a person...

  8. 23 CFR 1340.8 - Quality control.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... OBSERVATIONAL SURVEYS OF SEAT BELT USE Survey Design Requirements § 1340.8 Quality control. (a) Quality control... control monitors involved in seat belt use surveys shall have received training in data collection...) Statistical review. Survey results shall be reviewed and approved by a survey statistician, i.e., a person...

  9. 23 CFR 1340.8 - Quality control.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... OBSERVATIONAL SURVEYS OF SEAT BELT USE Survey Design Requirements § 1340.8 Quality control. (a) Quality control... control monitors involved in seat belt use surveys shall have received training in data collection...) Statistical review. Survey results shall be reviewed and approved by a survey statistician, i.e., a person...

  10. Simple Check Valves for Microfluidic Devices

    NASA Technical Reports Server (NTRS)

    Willis, Peter A.; Greer, Harold F.; Smith, J. Anthony

    2010-01-01

    A simple design concept for check valves has been adopted for microfluidic devices that consist mostly of (1) deformable fluorocarbon polymer membranes sandwiched between (2) borosilicate float glass wafers into which channels, valve seats, and holes have been etched. The first microfluidic devices in which these check valves are intended to be used are micro-capillary electrophoresis (microCE) devices undergoing development for use on Mars in detecting compounds indicative of life. In this application, it will be necessary to store some liquid samples in reservoirs in the devices for subsequent laboratory analysis, and check valves are needed to prevent cross-contamination of the samples. The simple check-valve design concept is also applicable to other microfluidic devices and to fluidic devices in general. These check valves are simplified microscopic versions of conventional rubber- flap check valves that are parts of numerous industrial and consumer products. These check valves are fabricated, not as separate components, but as integral parts of microfluidic devices. A check valve according to this concept consists of suitably shaped portions of a deformable membrane and the two glass wafers between which the membrane is sandwiched (see figure). The valve flap is formed by making an approximately semicircular cut in the membrane. The flap is centered over a hole in the lower glass wafer, through which hole the liquid in question is intended to flow upward into a wider hole, channel, or reservoir in the upper glass wafer. The radius of the cut exceeds the radius of the hole by an amount large enough to prevent settling of the flap into the hole. As in a conventional rubber-flap check valve, back pressure in the liquid pushes the flap against the valve seat (in this case, the valve seat is the adjacent surface of the lower glass wafer), thereby forming a seal that prevents backflow.

  11. 42 CFR 84.41 - Quality control plans; contents.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Quality control plans; contents. 84.41 Section 84... AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Quality Control § 84.41 Quality control plans; contents. (a) Each quality control plan shall contain provisions for the...

  12. 42 CFR 84.41 - Quality control plans; contents.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Quality control plans; contents. 84.41 Section 84... AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Quality Control § 84.41 Quality control plans; contents. (a) Each quality control plan shall contain provisions for the...

  13. 42 CFR 84.41 - Quality control plans; contents.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Quality control plans; contents. 84.41 Section 84... AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Quality Control § 84.41 Quality control plans; contents. (a) Each quality control plan shall contain provisions for the...

  14. 42 CFR 84.41 - Quality control plans; contents.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Quality control plans; contents. 84.41 Section 84... AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Quality Control § 84.41 Quality control plans; contents. (a) Each quality control plan shall contain provisions for the...

  15. 42 CFR 84.41 - Quality control plans; contents.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Quality control plans; contents. 84.41 Section 84... AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Quality Control § 84.41 Quality control plans; contents. (a) Each quality control plan shall contain provisions for the...

  16. Instrument Quality Control.

    PubMed

    Jayakody, Chatura; Hull-Ryde, Emily A

    2016-01-01

    Well-defined quality control (QC) processes are used to determine whether a certain procedure or action conforms to a widely accepted standard and/or set of guidelines, and are important components of any laboratory quality assurance program (Popa-Burke et al., J Biomol Screen 14: 1017-1030, 2009). In this chapter, we describe QC procedures useful for monitoring the accuracy and precision of laboratory instrumentation, most notably automated liquid dispensers. Two techniques, gravimetric QC and photometric QC, are highlighted in this chapter. When used together, these simple techniques provide a robust process for evaluating liquid handler accuracy and precision, and critically underpin high-quality research programs.

  17. Feasibility study of using statistical process control to customized quality assurance in proton therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rah, Jeong-Eun; Oh, Do Hoon; Shin, Dongho

    Purpose: To evaluate and improve the reliability of proton quality assurance (QA) processes and, to provide an optimal customized tolerance level using the statistical process control (SPC) methodology. Methods: The authors investigated the consistency check of dose per monitor unit (D/MU) and range in proton beams to see whether it was within the tolerance level of the daily QA process. This study analyzed the difference between the measured and calculated ranges along the central axis to improve the patient-specific QA process in proton beams by using process capability indices. Results: The authors established a customized tolerance level of ±2% formore » D/MU and ±0.5 mm for beam range in the daily proton QA process. In the authors’ analysis of the process capability indices, the patient-specific range measurements were capable of a specification limit of ±2% in clinical plans. Conclusions: SPC methodology is a useful tool for customizing the optimal QA tolerance levels and improving the quality of proton machine maintenance, treatment delivery, and ultimately patient safety.« less

  18. Feasibility study of using statistical process control to customized quality assurance in proton therapy.

    PubMed

    Rah, Jeong-Eun; Shin, Dongho; Oh, Do Hoon; Kim, Tae Hyun; Kim, Gwe-Ya

    2014-09-01

    To evaluate and improve the reliability of proton quality assurance (QA) processes and, to provide an optimal customized tolerance level using the statistical process control (SPC) methodology. The authors investigated the consistency check of dose per monitor unit (D/MU) and range in proton beams to see whether it was within the tolerance level of the daily QA process. This study analyzed the difference between the measured and calculated ranges along the central axis to improve the patient-specific QA process in proton beams by using process capability indices. The authors established a customized tolerance level of ±2% for D/MU and ±0.5 mm for beam range in the daily proton QA process. In the authors' analysis of the process capability indices, the patient-specific range measurements were capable of a specification limit of ±2% in clinical plans. SPC methodology is a useful tool for customizing the optimal QA tolerance levels and improving the quality of proton machine maintenance, treatment delivery, and ultimately patient safety.

  19. 14 CFR 145.211 - Quality control system.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Quality control system. 145.211 Section 145...) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Operating Rules § 145.211 Quality control system. (a) A certificated repair station must establish and maintain a quality control system acceptable to...

  20. 18 CFR 12.40 - Quality control programs.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false Quality control... PROJECT WORKS Other Responsibilities of Applicant or Licensee § 12.40 Quality control programs. (a... meeting any requirements or standards set by the Regional Engineer. If a quality control program is...

  1. 18 CFR 12.40 - Quality control programs.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Quality control... PROJECT WORKS Other Responsibilities of Applicant or Licensee § 12.40 Quality control programs. (a... meeting any requirements or standards set by the Regional Engineer. If a quality control program is...

  2. 14 CFR 145.211 - Quality control system.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Quality control system. 145.211 Section 145...) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Operating Rules § 145.211 Quality control system. (a) A certificated repair station must establish and maintain a quality control system acceptable to...

  3. MPST Software: grl_pef_check

    NASA Technical Reports Server (NTRS)

    Call, Jared A.; Kwok, John H.; Fisher, Forest W.

    2013-01-01

    This innovation is a tool used to verify and validate spacecraft sequences at the predicted events file (PEF) level for the GRAIL (Gravity Recovery and Interior Laboratory, see http://www.nasa. gov/mission_pages/grail/main/index. html) mission as part of the Multi-Mission Planning and Sequencing Team (MPST) operations process to reduce the possibility for errors. This tool is used to catch any sequence related errors or issues immediately after the seqgen modeling to streamline downstream processes. This script verifies and validates the seqgen modeling for the GRAIL MPST process. A PEF is provided as input, and dozens of checks are performed on it to verify and validate the command products including command content, command ordering, flight-rule violations, modeling boundary consistency, resource limits, and ground commanding consistency. By performing as many checks as early in the process as possible, grl_pef_check streamlines the MPST task of generating GRAIL command and modeled products on an aggressive schedule. By enumerating each check being performed, and clearly stating the criteria and assumptions made at each step, grl_pef_check can be used as a manual checklist as well as an automated tool. This helper script was written with a focus on enabling the user with the information they need in order to evaluate a sequence quickly and efficiently, while still keeping them informed and active in the overall sequencing process. grl_pef_check verifies and validates the modeling and sequence content prior to investing any more effort into the build. There are dozens of various items in the modeling run that need to be checked, which is a time-consuming and errorprone task. Currently, no software exists that provides this functionality. Compared to a manual process, this script reduces human error and saves considerable man-hours by automating and streamlining the mission planning and sequencing task for the GRAIL mission.

  4. Regular Check-Ups Are Important

    MedlinePlus

    ... Halloween Prom Tips Spring Break Valentine Tips Winter Holiday Tips 12 Ways Holiday Song Healthy Living Check-Ups are Important Check- ... Test Wash Hands Stay Warm Have a Healthy Holiday Don’t Drink and Drive Widgets Healthy People ...

  5. Body checking behaviors in men.

    PubMed

    Walker, D Catherine; Anderson, Drew A; Hildebrandt, Thomas

    2009-06-01

    Males have been facing increasing pressure from the media to attain a lean, muscular physique, and are at risk for body dissatisfaction, disturbed eating and exercise behaviors, and abuse of appearance- and performance-enhancing drugs (APEDs). The aim of the current study was to examine the relationship between body checking and mood, symptoms of muscle dysmorphia, importance of shape and weight, and APED use in undergraduate males. Body checking in males was correlated with weight and shape concern, symptoms of muscle dysmorphia, depression, negative affect, and APED use. Body checking predicted APED use and uniquely accounted for the largest amount of variance in Muscle Dysmorphic Disorder Inventory (MDDI) scores (16%). Findings support the view that body checking is an important construct in male body image, muscle dysmorphia, and body change strategies and suggest a need for further research.

  6. Dual Check Valve and Method of Controlling Flow Through the Same

    NASA Technical Reports Server (NTRS)

    Corallo, Roger (Inventor)

    2016-01-01

    A dual check valve includes, a housing having a cavity fluidically connecting three ports, a movable member movably engaged within the cavity from at least a first position occluding a first port of the three ports, a second position occluding a second port of the three ports, and a third position allowing flow between both the first port, the second port and a third port of the three ports.

  7. 25 CFR 11.421 - Bad checks.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Bad checks. 11.421 Section 11.421 Indians BUREAU OF... Criminal Offenses § 11.421 Bad checks. (a) A person who issues or passes a check or similar sight order for..., and the issuer failed to make good within 10 days after receiving notice of that refusal. ...

  8. Good health checks according to the general public; expectations and criteria: a focus group study.

    PubMed

    Stol, Yrrah H; Asscher, Eva C A; Schermer, Maartje H N

    2018-06-22

    , we recommend the following measures to timely adjust false expectations: advertisements that give an accurate impression of health check offers, and the installation of a quality mark.

  9. Quality Control in construction.

    DTIC Science & Technology

    1984-01-01

    behavioral scientists. In 1962, Dr. Kaoru Ishikawa gave shape to the form of training which featured intradepartmental groups of ten or so workers seated...and Japanese circles bears closer scrutiny. 4.3.1 Japanese Ingredients of Quality The founder of quality circles, Dr. Kaoru Ishikawa , gives six...around 51 a table; hence the name Quality Control Circle. 4 Dr. 0 Ishikawa was an engineering professor at Tokyo University, and the circles were

  10. The Pan European Phenological Database PEP725: Data Content and Data Quality Control Procedures

    NASA Astrophysics Data System (ADS)

    Jurkovic, Anita; Hübner, Thomas; Koch, Elisabeth; Lipa, Wolfgang; Scheifinger, Helfried; Ungersböck, Markus; Zach-Hermann, Susanne

    2014-05-01

    Phenology - the study of the timing of recurring biological events in the animal and plant world - has become an important approach for climate change impact studies in recent years. It is therefore a "conditio sine qua non" to collect, archive, digitize, control and update phenological datasets. Thus and with regard to cross-border cooperation and activities it was necessary to establish, operate and promote a pan European phenological database (PEP725). Such a database - designed and tested under cost action 725 in 2004 and further developed and maintained in the framework of the EUMETNET program PEP725 - collects data from different European governmental and nongovernmental institutions and thus offers a unique compilation of plant phenological observations. The data follows the same classification scheme - the so called BBCH coding system - that makes datasets comparable. Europe had a long tradition in the observation of phenological events: the history of collecting phenological data and their usage in climatology began in 1751. The first datasets in PEP725 date back to 1868. However, there are only a few observations available until 1950. From 1951 onwards, the phenological networks all over Europe developed rapidly: Currently, PEP725 provides about 9 million records from 23 European countries (covering approximately 50% of Europe). To supply the data in a good and uniform quality it is essential and worthwhile to establish and develop data quality control procedures. Consequently, one of the main tasks within PEP725 is the conception of a multi-stage-quality control. Currently the tests are stepwise composed: completeness -, plausibility -, time consistency -, climatological - and statistical checks. In a nutshell: The poster exemplifies the status quo of the data content of the PEP725 database and incipient stages of used and planned quality controls, respectively. For more details, we would also like to promote and refer to the PEP725 website (http

  11. [Company Wide Quality Control (total quality): methodological principles and intervention techniques for step-by-step improvement].

    PubMed

    Corbara, F; Di Cristofaro, E

    1996-01-01

    The concept of Quality is particularly up to date and not a new one for the Journal. The need for better Quality is a must also in Medical care. Quality doesn't mean additional costs and excessive burden for the co-workers. On the contrary, initial costs can be compensated for through a more rational utilisation of the resources. The consequent better service for the patient results in an ameliorated working environment, with high profits. Fundamental requirements for reaching concrete results are: 1) the convinced involvement in the idea of all levels (division, service, laboratory) in order to have the different groups act in synergism towards common goals; 2) the knowledge of appropriate methods. The Authors examine this last point with a deep analysis of the techniques involved in Company Wide Quality Control (C.W.Q.C.) or Total Quality. The improving process has to the continuous and proceed in small steps, each time being constituted by 4 different phases, represented by the PDCA cycle, or Demining wheel, where: P = PLAN, which means plan before acting; D = DO, perform what has been planned; C = CHECK, verify the results; A = ACT, standardize if the results are positive, repeat the process if negative. Each process of improvement implies a prior precise definition of a project, i.e. a problem whose solution has been planned. The project must always presume: a specific subject--a goal--one or more people to reach it--a limited time to work it out. The most effective way to ameliorate Quality is performing projects. Step by Step amelioration is synonymous of performance of many projects. A brilliant way to produce many projects remains their "industrialization", which can be reached by means of 6 basic criteria: 1) full involvement of the Direction; 2) potential co-working in the projects of all employees; 3) employment of simple instruments; 4) respect of a few procedural formalities; 5) rewarding of personnel; 6) continuous promotion of the concepts of

  12. 38 CFR 3.1003 - Returned and canceled checks.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Returned and canceled... canceled checks. Where the payee of a check for benefits has died prior to negotiating the check, the check shall be returned to the issuing office and canceled. (a) The amount represented by the returned check...

  13. 30 CFR 74.6 - Quality control.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Quality control. 74.6 Section 74.6 Mineral... control. The applicant shall describe the way in which each lot of components will be sampled and tested... of the CMDPSU will be maintained in production through adequate quality control procedures, MSHA and...

  14. 30 CFR 74.6 - Quality control.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Quality control. 74.6 Section 74.6 Mineral... control. The applicant shall describe the way in which each lot of components will be sampled and tested... of the CMDPSU will be maintained in production through adequate quality control procedures, MSHA and...

  15. 30 CFR 74.6 - Quality control.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Quality control. 74.6 Section 74.6 Mineral... control. The applicant shall describe the way in which each lot of components will be sampled and tested... of the CMDPSU will be maintained in production through adequate quality control procedures, MSHA and...

  16. Reducing Check-in Errors at Brigham Young University through Statistical Process Control

    ERIC Educational Resources Information Center

    Spackman, N. Andrew

    2005-01-01

    The relationship between the library and its patrons is damaged and the library's reputation suffers when returned items are not checked in. An informal survey reveals librarians' concern for this problem and their efforts to combat it, although few libraries collect objective measurements of errors or the effects of improvement efforts. Brigham…

  17. PFReports: A program for systematic checking of annual peaks in NWISWeb

    USGS Publications Warehouse

    Ryberg, Karen R.

    2008-01-01

    problems with the PFF were time consuming, laborious, and often ineffective. This new suite of checks represents an effort to automate identification of specific problems without plotting or printing large amounts of data that may not have problems. In addition, the results of the checks of the peak flow files are delivered through the World Wide Web with links to individual reports so that WSCs can focus on specific problems in an organized and standardized fashion. Over the years, technical reviews, regional-flood studies, and user inquiries have identified many minor and some major problems in the PFF. However, the cumbersome nature of the PFF editor and a lack of analytical tools have hampered efforts at quality assurance/quality control (QA/QC) and subsequently to make needed revisions to the database. This document is organized to provide information regarding PFReports, especially those tests involving regression and to provide an overview of the review procedures for utilizing the output. It also may be used as a reference for the data qualification codes and abbreviations for the tests. Results of the checks for all peak flow files (March 2008) are available at http://nd.water.usgs.gov/internal/pfreports/.

  18. Implementing Check in/Check out for Students with Intellectual Disability in Self-Contained Classrooms

    ERIC Educational Resources Information Center

    Boden, Lauren J.; Ennis, Robin P.; Jolivette, Kristine

    2012-01-01

    Check in/check out (CICO) is a secondary-tier intervention implemented within the framework of schoolwide positive behavior interventions and supports (SWPBIS) that uses school-based contingencies to encourage positive behavior. CICO is a five-step cycle which uses daily progress report cards (DPR) to monitor progress toward schoolwide or…

  19. Guidance for Efficient Small Animal Imaging Quality Control.

    PubMed

    Osborne, Dustin R; Kuntner, Claudia; Berr, Stuart; Stout, David

    2017-08-01

    Routine quality control is a critical aspect of properly maintaining high-performance small animal imaging instrumentation. A robust quality control program helps produce more reliable data both for academic purposes and as proof of system performance for contract imaging work. For preclinical imaging laboratories, the combination of costs and available resources often limits their ability to produce efficient and effective quality control programs. This work presents a series of simplified quality control procedures that are accessible to a wide range of preclinical imaging laboratories. Our intent is to provide minimum guidelines for routine quality control that can assist preclinical imaging specialists in setting up an appropriate quality control program for their facility.

  20. 42 CFR 84.256 - Quality control requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Quality control requirements. 84.256 Section 84.256... § 84.256 Quality control requirements. (a) In addition to the construction and performance requirements specified in §§ 84.251, 84.252, 84.253, 84.254, and 84.255, the quality control requirements in paragraphs...

  1. 42 CFR 84.256 - Quality control requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Quality control requirements. 84.256 Section 84.256... § 84.256 Quality control requirements. (a) In addition to the construction and performance requirements specified in §§ 84.251, 84.252, 84.253, 84.254, and 84.255, the quality control requirements in paragraphs...

  2. 42 CFR 84.256 - Quality control requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Quality control requirements. 84.256 Section 84.256... § 84.256 Quality control requirements. (a) In addition to the construction and performance requirements specified in §§ 84.251, 84.252, 84.253, 84.254, and 84.255, the quality control requirements in paragraphs...

  3. 42 CFR 84.256 - Quality control requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Quality control requirements. 84.256 Section 84.256... § 84.256 Quality control requirements. (a) In addition to the construction and performance requirements specified in §§ 84.251, 84.252, 84.253, 84.254, and 84.255, the quality control requirements in paragraphs...

  4. 42 CFR 84.256 - Quality control requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Quality control requirements. 84.256 Section 84.256... § 84.256 Quality control requirements. (a) In addition to the construction and performance requirements specified in §§ 84.251, 84.252, 84.253, 84.254, and 84.255, the quality control requirements in paragraphs...

  5. Evaluating the impact of AMDAR data quality control in China on the short-range convection forecasts using the WRF model

    NASA Astrophysics Data System (ADS)

    Wang, Xiaofeng; Jiang, Qin; Zhang, Lei

    2016-04-01

    A quality control system for the Aircraft Meteorological Data Relay (AMDAR) data has been implemented in China. This system is an extension to the AMDAR quality control system used at the US National Centers for Environmental Prediction. We present a study in which the characteristics of each AMDAR data quality type were examined and the impact of the AMDAR data quality system on short-range convective weather forecasts using the WRF model was investigated. The main results obtained from this study are as follows. (1) The hourly rejection rate of AMDAR data during 2014 was 5.79%, and most of the rejections happened in Near Duplicate Check. (2) There was a significant diurnal variation for both quantity and quality of AMDAR data. Duplicated reports increased with the increase of data quantity, while suspicious and disorderly reports decreased with the increase of data quantity. (3) The characteristics of the data quality were different in each model layer, with the quality problems occurring mainly at the surface as well as at the height where the power or the flight mode of the aircraft underwent adjustment. (4) Assimilating the AMDAR data improved the forecast accuracy, particularly over the region where strong convection occurred. (5) Significant improvements made by assimilating AMDAR data were found after six hours into the model forecast. The conclusion from this study is that the newly implemented AMDAR data quality system can help improve the accuracy of short-range convection forecasts using the WRF model.

  6. Evaluation of the TrueBeam machine performance check (MPC) beam constancy checks for flattened and flattening filter-free (FFF) photon beams.

    PubMed

    Barnes, Michael P; Greer, Peter B

    2017-01-01

    Machine Performance Check (MPC) is an automated and integrated image-based tool for verification of beam and geometric performance of the TrueBeam linac. The aims of the study were to evaluate the MPC beam performance tests against current daily quality assurance (QA) methods, to compare MPC performance against more accurate monthly QA tests and to test the sensitivity of MPC to changes in beam performance. The MPC beam constancy checks test the beam output, uniformity, and beam center against the user defined baseline. MPC was run daily over a period of 5 months (n = 115) in parallel with the Daily QA3 device. Additionally, IC Profiler, in-house EPID tests, and ion chamber measurements were performed biweekly and results presented in a form directly comparable to MPC. The sensitivity of MPC was investigated using controlled adjustments of output, beam angle, and beam position steering. Over the period, MPC output agreed with ion chamber to within 0.6%. For an output adjustment of 1.2%, MPC was found to agree with ion chamber to within 0.17%. MPC beam center was found to agree with the in-house EPID method within 0.1 mm. A focal spot position adjustment of 0.4 mm (at isocenter) was measured with MPC beam center to within 0.01 mm. An average systematic offset of 0.5% was measured in the MPC uniformity and agreement of MPC uniformity with symmetry measurements was found to be within 0.9% for all beams. MPC uniformity detected a change in beam symmetry of 1.5% to within 0.3% and 0.9% of IC Profiler for flattened and FFF beams, respectively. © 2016 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  7. Space shuttle prototype check valve development

    NASA Technical Reports Server (NTRS)

    Tellier, G. F.

    1976-01-01

    Contaminant-resistant seal designs and a dynamically stable prototype check valve for the orbital maneuvering and reaction control helium pressurization systems of the space shuttle were developed. Polymer and carbide seal models were designed and tested. Perfluoroelastomers compatible with N2O4 and N2H4 types were evaluated and compared with Teflon in flat and captive seal models. Low load sealing and contamination resistance tests demonstrated cutter seal superiority over polymer seals. Ceramic and carbide materials were evaluated for N2O4 service using exposure to RFNA as a worst case screen; chemically vapor deposited tungsten carbide was shown to be impervious to the acid after 6 months immersion. A unique carbide shell poppet/cutter seat check valve was designed and tested to demonstrate low cracking pressure ( 2.0 psid), dynamic stability under all test bench flow conditions, contamination resistance (0.001 inch CRES wires cut with 1.5 pound seat load) and long life of 100,000 cycles (leakage 1.0 scc/hr helium from 0.1 to 400 psig).

  8. Temporal effects of post-fire check dam construction on soil functionality in SE Spain.

    PubMed

    González-Romero, J; Lucas-Borja, M E; Plaza-Álvarez, P A; Sagra, J; Moya, D; De Las Heras, J

    2018-06-09

    Wildfire has historically been an alteration factor in Mediterranean basins. Despite Mediterranean ecosystems' high resilience, wildfire accelerates erosion and degradation processes, and also affects soil functionality by affecting nutrient cycles and soil structure. In semi-arid Mediterranean basins, check dams are usually built in gullies and channels after fire as a measure against soil erosion. Although check dams have proven efficient action to reduce erosion rates, studies about how they affect soil functionality are lacking. Our approach focuses on how soil functionality, defined as a combination of physico-chemical and biological indicators, is locally affected by check dam construction and the evolution of this effect over time. Soils were sampled in eight check dams in two semi-arid areas at SE Spain, which were affected by wildfire in 2012 and 2016. The study findings reveal that by altering sediments cycle and transport, check dams influence soil's main physico-chemical and biochemical characteristics. Significant differences were found between check dam-affected zones and the control ones for many indicators such as organic matter content, electrical conductivity or enzymatic activity. According to the ANOVA results, interaction between check dams influence and time after fire, was a crucial factor. PCA results clearly showed check-dams influence on soil functionality. Copyright © 2018. Published by Elsevier B.V.

  9. 12 CFR Appendix A to Part 229 - Routing Number Guide to Next-Day Availability Checks and Local Checks

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 3 2010-01-01 2010-01-01 false Routing Number Guide to Next-Day Availability Checks and Local Checks A Appendix A to Part 229 Banks and Banking FEDERAL RESERVE SYSTEM (CONTINUED) BOARD OF GOVERNORS OF THE FEDERAL RESERVE SYSTEM AVAILABILITY OF FUNDS AND COLLECTION OF CHECKS...

  10. 3D printing X-Ray Quality Control Phantoms. A Low Contrast Paradigm

    NASA Astrophysics Data System (ADS)

    Kapetanakis, I.; Fountos, G.; Michail, C.; Valais, I.; Kalyvas, N.

    2017-11-01

    Current 3D printing technology products may be usable in various biomedical applications. Such an application is the creation of X-ray quality control phantoms. In this work a self-assembled 3D printer (geeetech i3) was used for the design of a simple low contrast phantom. The printing material was Polylactic Acid (PLA) (100% printing density). Low contrast scheme was achieved by creating air-holes with different diameters and thicknesses, ranging from 1mm to 9mm. The phantom was irradiated at a Philips Diagnost 93 fluoroscopic installation at 40kV-70kV with the semi-automatic mode. The images were recorded with an Agfa cr30-x CR system and assessed with ImageJ software. The best contrast value observed was approximately 33%. In low contrast detectability check it was found that the 1mm diameter hole was always visible, for thickness larger or equal to 4mm. A reason for not being able to distinguish 1mm in smaller thicknesses might be the presence of printing patterns on the final image, which increased the structure noise. In conclusion the construction of a contrast resolution phantom with a 3D printer is feasible. The quality of the final product depends upon the printer accuracy and the material characteristics.

  11. OntoCheck: verifying ontology naming conventions and metadata completeness in Protégé 4

    PubMed Central

    2012-01-01

    Background Although policy providers have outlined minimal metadata guidelines and naming conventions, ontologies of today still display inter- and intra-ontology heterogeneities in class labelling schemes and metadata completeness. This fact is at least partially due to missing or inappropriate tools. Software support can ease this situation and contribute to overall ontology consistency and quality by helping to enforce such conventions. Objective We provide a plugin for the Protégé Ontology editor to allow for easy checks on compliance towards ontology naming conventions and metadata completeness, as well as curation in case of found violations. Implementation In a requirement analysis, derived from a prior standardization approach carried out within the OBO Foundry, we investigate the needed capabilities for software tools to check, curate and maintain class naming conventions. A Protégé tab plugin was implemented accordingly using the Protégé 4.1 libraries. The plugin was tested on six different ontologies. Based on these test results, the plugin could be refined, also by the integration of new functionalities. Results The new Protégé plugin, OntoCheck, allows for ontology tests to be carried out on OWL ontologies. In particular the OntoCheck plugin helps to clean up an ontology with regard to lexical heterogeneity, i.e. enforcing naming conventions and metadata completeness, meeting most of the requirements outlined for such a tool. Found test violations can be corrected to foster consistency in entity naming and meta-annotation within an artefact. Once specified, check constraints like name patterns can be stored and exchanged for later re-use. Here we describe a first version of the software, illustrate its capabilities and use within running ontology development efforts and briefly outline improvements resulting from its application. Further, we discuss OntoChecks capabilities in the context of related tools and highlight potential future

  12. OntoCheck: verifying ontology naming conventions and metadata completeness in Protégé 4.

    PubMed

    Schober, Daniel; Tudose, Ilinca; Svatek, Vojtech; Boeker, Martin

    2012-09-21

    Although policy providers have outlined minimal metadata guidelines and naming conventions, ontologies of today still display inter- and intra-ontology heterogeneities in class labelling schemes and metadata completeness. This fact is at least partially due to missing or inappropriate tools. Software support can ease this situation and contribute to overall ontology consistency and quality by helping to enforce such conventions. We provide a plugin for the Protégé Ontology editor to allow for easy checks on compliance towards ontology naming conventions and metadata completeness, as well as curation in case of found violations. In a requirement analysis, derived from a prior standardization approach carried out within the OBO Foundry, we investigate the needed capabilities for software tools to check, curate and maintain class naming conventions. A Protégé tab plugin was implemented accordingly using the Protégé 4.1 libraries. The plugin was tested on six different ontologies. Based on these test results, the plugin could be refined, also by the integration of new functionalities. The new Protégé plugin, OntoCheck, allows for ontology tests to be carried out on OWL ontologies. In particular the OntoCheck plugin helps to clean up an ontology with regard to lexical heterogeneity, i.e. enforcing naming conventions and metadata completeness, meeting most of the requirements outlined for such a tool. Found test violations can be corrected to foster consistency in entity naming and meta-annotation within an artefact. Once specified, check constraints like name patterns can be stored and exchanged for later re-use. Here we describe a first version of the software, illustrate its capabilities and use within running ontology development efforts and briefly outline improvements resulting from its application. Further, we discuss OntoChecks capabilities in the context of related tools and highlight potential future expansions. The OntoCheck plugin facilitates

  13. 40 CFR 86.327-79 - Quench checks; NOX analyzer.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for New Gasoline-Fueled and Diesel-Fueled Heavy-Duty Engines; Gaseous Exhaust Test Procedures § 86.327-79..., recalibrate and repeat the quench check. (4) Prior to testing, the difference between the calculated NOX...

  14. 40 CFR 86.327-79 - Quench checks; NOX analyzer.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for New Gasoline-Fueled and Diesel-Fueled Heavy-Duty Engines; Gaseous Exhaust Test Procedures § 86.327-79..., recalibrate and repeat the quench check. (4) Prior to testing, the difference between the calculated NOX...

  15. Recommendations of the DNA Commission of the International Society for Forensic Genetics (ISFG) on quality control of autosomal Short Tandem Repeat allele frequency databasing (STRidER).

    PubMed

    Bodner, Martin; Bastisch, Ingo; Butler, John M; Fimmers, Rolf; Gill, Peter; Gusmão, Leonor; Morling, Niels; Phillips, Christopher; Prinz, Mechthild; Schneider, Peter M; Parson, Walther

    2016-09-01

    The statistical evaluation of autosomal Short Tandem Repeat (STR) genotypes is based on allele frequencies. These are empirically determined from sets of randomly selected human samples, compiled into STR databases that have been established in the course of population genetic studies. There is currently no agreed procedure of performing quality control of STR allele frequency databases, and the reliability and accuracy of the data are largely based on the responsibility of the individual contributing research groups. It has been demonstrated with databases of haploid markers (EMPOP for mitochondrial mtDNA, and YHRD for Y-chromosomal loci) that centralized quality control and data curation is essential to minimize error. The concepts employed for quality control involve software-aided likelihood-of-genotype, phylogenetic, and population genetic checks that allow the researchers to compare novel data to established datasets and, thus, maintain the high quality required in forensic genetics. Here, we present STRidER (http://strider.online), a publicly available, centrally curated online allele frequency database and quality control platform for autosomal STRs. STRidER expands on the previously established ENFSI DNA WG STRbASE and applies standard concepts established for haploid and autosomal markers as well as novel tools to reduce error and increase the quality of autosomal STR data. The platform constitutes a significant improvement and innovation for the scientific community, offering autosomal STR data quality control and reliable STR genotype estimates. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  16. [Cleaning and disinfection in nursing homes. Data on quality of structure, process and outcome in nursing homes in Frankfurt am Main, Germany, 2011].

    PubMed

    Heudorf, U; Gasteyer, S; Samoiski, Y; Voigt, K

    2012-08-01

    Due to the Infectious Disease Prevention Act, public health services in Germany are obliged to check the infection prevention in hospitals and other medical facilities as well as in nursing homes. In Frankfurt/Main, Germany, standardized control visits have been performed for many years. In 2011 focus was laid on cleaning and disinfection of surfaces. All 41 nursing homes were checked according to a standardized checklist covering quality of structure (i.e. staffing, hygiene concept), quality of process (observation of the cleaning processes in the homes) and quality of output, which was monitored by checking the cleaning of fluorescent marks which had been applied some days before and should have been removed via cleaning in the following days before the final check. In more than two thirds of the homes, cleaning personnel were salaried, in one third external personnel were hired. Of the homes 85% provided service clothing and all of them offered protective clothing. All homes had established hygiene and cleaning concepts, however, in 15% of the homes concepts for the handling of Norovirus and in 30% concepts for the handling of Clostridium difficile were missing. Regarding process quality only half of the processes observed, i.e. cleaning of hand contact surfaces, such as handrails, washing areas and bins, were correct. Only 44% of the cleaning controls were correct with enormous differences between the homes (0-100%). The correlation between quality of process and quality of output was significant. There was good quality of structure in the homes but regarding quality of process and outcome there was great need for improvement. This was especially due to faults in communication and coordination between cleaning personnel and nursing personnel. Quality outcome was neither associated with the number of the places for residents nor with staffing. Thus, not only quality of structure but also quality of process and outcome should be checked by the public health

  17. 7 CFR 58.928 - Quality control tests.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... quality test shall be made to determine product stability. ... 7 Agriculture 3 2013-01-01 2013-01-01 false Quality control tests. 58.928 Section 58.928... Procedures § 58.928 Quality control tests. All dairy products and other ingredients shall be subject to...

  18. 7 CFR 58.928 - Quality control tests.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... quality test shall be made to determine product stability. ... 7 Agriculture 3 2012-01-01 2012-01-01 false Quality control tests. 58.928 Section 58.928... Procedures § 58.928 Quality control tests. All dairy products and other ingredients shall be subject to...

  19. Changes in radiological protection and quality control in Spanish dental installations: 1996-2003.

    PubMed

    Alcaraz-Baños, Miguel; Parra-Pérez, María del Carmen; Armero-Barranco, David; Velasco-Hidalgo, Francisco; Velasco-Hidalgo, Esteban

    2009-10-01

    The European Union has established specific directives concerning radiological protection which are obligatory for member States. In addition, all Spanish dental clinics with radiological equipment are required to have an annual quality control check. To analyze the effect of new European legislation on dental radiological practice in Spain and to determine whether it has resulted in lower doses being administered to patients. A total of 10,171 official radiological quality control reports on Spanish dental clinics, covering 16 autonomous regions, were studied following the passing of Royal Decree 2071/1995 on quality criteria in radiodiagnostic installations. The reports, compiled by U.T.P.R Asigma S.A., a company authorised by the Nuclear Safety Council, cover the years 1996 to 2003, which has enabled us to monitor the evolution of radiological procedures in dental clinics over a seven year period. According to the reports for 2003, 77.3 % of clinics complied with EU requirements, using equipment of 70 kVp, 8 mA, 1.5 mm Al filters, with a collimator length of 20 cm. However, non-compliance was detected in approximately a third (30.8%) of the equipment inspected: alterations in the kilovoltage used, exposure time, performance of the tubing, dosage, linearity/intensity of current and acoustic-luminous signal 6.86%. The mean skin dose reached 3.11 mGy for patients who received an x-ray of an upper molar, representing a decrease of 18% over the seven years studied. there has obviously been a general improvement in the parameters studied, but only 77.3% of the installations complied fully with official EU regulations concerning dental radiological protection.

  20. Biochemia Medica has started using the CrossCheck plagiarism detection software powered by iThenticate

    PubMed Central

    Šupak-Smolčić, Vesna; Šimundić, Ana-Maria

    2013-01-01

    In February 2013, Biochemia Medica has joined CrossRef, which enabled us to implement CrossCheck plagiarism detection service. Therefore, all manuscript submitted to Biochemia Medica are now first assigned to Research integrity editor (RIE), before sending the manuscript for peer-review. RIE submits the text to CrossCheck analysis and is responsible for reviewing the results of the text similarity analysis. Based on the CrossCheck analysis results, RIE subsequently provides a recommendation to the Editor-in-chief (EIC) on whether the manuscript should be forwarded to peer-review, corrected for suspected parts prior to peer-review or immediately rejected. Final decision on the manuscript is, however, with the EIC. We hope that our new policy and manuscript processing algorithm will help us to further increase the overall quality of our Journal. PMID:23894858

  1. Proteomics Quality Control: Quality Control Software for MaxQuant Results.

    PubMed

    Bielow, Chris; Mastrobuoni, Guido; Kempa, Stefan

    2016-03-04

    Mass spectrometry-based proteomics coupled to liquid chromatography has matured into an automatized, high-throughput technology, producing data on the scale of multiple gigabytes per instrument per day. Consequently, an automated quality control (QC) and quality analysis (QA) capable of detecting measurement bias, verifying consistency, and avoiding propagation of error is paramount for instrument operators and scientists in charge of downstream analysis. We have developed an R-based QC pipeline called Proteomics Quality Control (PTXQC) for bottom-up LC-MS data generated by the MaxQuant software pipeline. PTXQC creates a QC report containing a comprehensive and powerful set of QC metrics, augmented with automated scoring functions. The automated scores are collated to create an overview heatmap at the beginning of the report, giving valuable guidance also to nonspecialists. Our software supports a wide range of experimental designs, including stable isotope labeling by amino acids in cell culture (SILAC), tandem mass tags (TMT), and label-free data. Furthermore, we introduce new metrics to score MaxQuant's Match-between-runs (MBR) functionality by which peptide identifications can be transferred across Raw files based on accurate retention time and m/z. Last but not least, PTXQC is easy to install and use and represents the first QC software capable of processing MaxQuant result tables. PTXQC is freely available at https://github.com/cbielow/PTXQC .

  2. 48 CFR 22.406-7 - Compliance checking.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Compliance checking. 22... Involving Construction 22.406-7 Compliance checking. (a) General. The contracting officer shall make checks and investigations on all contracts covered by this subpart as may be necessary to ensure compliance...

  3. 7 CFR 981.442 - Quality control.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Quality control. 981.442 Section 981.442 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Administrative Rules and Regulations § 981.442 Quality control. (a) Incoming. Pursuant to § 981.42(a), the...

  4. 7 CFR 981.442 - Quality control.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Quality control. 981.442 Section 981.442 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING AGREEMENTS... Administrative Rules and Regulations § 981.442 Quality control. (a) Incoming. Pursuant to § 981.42(a), the...

  5. 7 CFR 981.442 - Quality control.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Quality control. 981.442 Section 981.442 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Administrative Rules and Regulations § 981.442 Quality control. (a) Incoming. Pursuant to § 981.42(a), the...

  6. 30 CFR 75.1715 - Identification check system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... system. [Statutory Provisions] Each operator of a coal mine shall establish a check-in and check-out system which will provide positive identification of every person underground, and will provide an... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Identification check system. 75.1715 Section 75...

  7. 30 CFR 75.1715 - Identification check system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... system. [Statutory Provisions] Each operator of a coal mine shall establish a check-in and check-out system which will provide positive identification of every person underground, and will provide an... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Identification check system. 75.1715 Section 75...

  8. 30 CFR 75.1715 - Identification check system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... system. [Statutory Provisions] Each operator of a coal mine shall establish a check-in and check-out system which will provide positive identification of every person underground, and will provide an... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Identification check system. 75.1715 Section 75...

  9. 30 CFR 75.1715 - Identification check system.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... system. [Statutory Provisions] Each operator of a coal mine shall establish a check-in and check-out system which will provide positive identification of every person underground, and will provide an... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Identification check system. 75.1715 Section 75...

  10. 30 CFR 75.1715 - Identification check system.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... system. [Statutory Provisions] Each operator of a coal mine shall establish a check-in and check-out system which will provide positive identification of every person underground, and will provide an... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Identification check system. 75.1715 Section 75...

  11. Aerospell Supplemental Spell Check File

    NASA Technical Reports Server (NTRS)

    2000-01-01

    Aerospell is a supplemental spell check file that can be used as a resource for researchers, writers, editors, students, and others who compose scientific and technical texts. The file extends the general spell check dictionaries of word processors by adding more than 13,000 words used in a broad range of aerospace and related disciplines.

  12. 31 CFR 248.6 - Recovery of original check.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Recovery of original check. 248.6... § 248.6 Recovery of original check. (a) If the claimant recovers an original check after he has... or agency concerned regarding the negotiability of such original check. (b) In the event the...

  13. Identification of Poetntially Creative Persons from the Adjective Check List

    ERIC Educational Resources Information Center

    Domino, George

    1970-01-01

    The initial development and cross validation of a Creativity (CR) scale for the Adjective Check List (ACL) is presented. The Cr scale significantly differentiated creatives from controls in every field of endeavor, but was not influenced by sex or type of creativity. (Author)

  14. Contributions of CCLM to advances in quality control.

    PubMed

    Kazmierczak, Steven C

    2013-01-01

    Abstract The discipline of laboratory medicine is relatively young when considered in the context of the history of medicine itself. The history of quality control, within the context of laboratory medicine, also enjoys a relatively brief, but rich history. Laboratory quality control continues to evolve along with advances in automation, measurement techniques and information technology. Clinical Chemistry and Laboratory Medicine (CCLM) has played a key role in helping disseminate information about the proper use and utility of quality control. Publication of important advances in quality control techniques and dissemination of guidelines concerned with laboratory quality control has undoubtedly helped readers of this journal keep up to date on the most recent developments in this field.

  15. 12 CFR 229.52 - Substitute check warranties.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 3 2010-01-01 2010-01-01 false Substitute check warranties. 229.52 Section 229.52 Banks and Banking FEDERAL RESERVE SYSTEM (CONTINUED) BOARD OF GOVERNORS OF THE FEDERAL RESERVE..., presents, or returns a substitute check (or a paper or electronic representation of a substitute check) for...

  16. 12 CFR 229.52 - Substitute check warranties.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 12 Banks and Banking 3 2011-01-01 2011-01-01 false Substitute check warranties. 229.52 Section 229.52 Banks and Banking FEDERAL RESERVE SYSTEM (CONTINUED) BOARD OF GOVERNORS OF THE FEDERAL RESERVE..., presents, or returns a substitute check (or a paper or electronic representation of a substitute check) for...

  17. 42 CFR 455.436 - Federal database checks.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 4 2012-10-01 2012-10-01 false Federal database checks. 455.436 Section 455.436....436 Federal database checks. The State Medicaid agency must do all of the following: (a) Confirm the... databases. (b) Check the Social Security Administration's Death Master File, the National Plan and Provider...

  18. 42 CFR 455.436 - Federal database checks.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 4 2011-10-01 2011-10-01 false Federal database checks. 455.436 Section 455.436....436 Federal database checks. The State Medicaid agency must do all of the following: (a) Confirm the... databases. (b) Check the Social Security Administration's Death Master File, the National Plan and Provider...

  19. 42 CFR 455.436 - Federal database checks.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 4 2014-10-01 2014-10-01 false Federal database checks. 455.436 Section 455.436....436 Federal database checks. The State Medicaid agency must do all of the following: (a) Confirm the... databases. (b) Check the Social Security Administration's Death Master File, the National Plan and Provider...

  20. 42 CFR 455.436 - Federal database checks.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 4 2013-10-01 2013-10-01 false Federal database checks. 455.436 Section 455.436....436 Federal database checks. The State Medicaid agency must do all of the following: (a) Confirm the... databases. (b) Check the Social Security Administration's Death Master File, the National Plan and Provider...

  1. Environmental Reality Check.

    ERIC Educational Resources Information Center

    Manicone, Santo

    2001-01-01

    Discusses the importance of educational facilities conducting "reality check" self-audits to uncover the real truth behind underlying environmental problems. An environmental compliance multimedia checklist is included. (GR)

  2. 7 CFR 58.733 - Quality control tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Quality control tests. 58.733 Section 58.733... Procedures § 58.733 Quality control tests. (a) Chemical analyses. The following chemical analyses shall be... pasteurization by means of the phosphatase test, as well as any other tests necessary to assure good quality...

  3. 7 CFR 58.733 - Quality control tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.733 Section 58.733... Procedures § 58.733 Quality control tests. (a) Chemical analyses. The following chemical analyses shall be... pasteurization by means of the phosphatase test, as well as any other tests necessary to assure good quality...

  4. 7 CFR 1944.540 - Requesting TSA checks.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 13 2010-01-01 2009-01-01 true Requesting TSA checks. 1944.540 Section 1944.540... TSA checks. (a) The initial TSA check may cover the applicant's needs for the first calendar month. If... the next whole month. (b) The initial advance of TSA grant funds may not be requested simultaneously...

  5. Quality-control design for surface-water sampling in the National Water-Quality Network

    USGS Publications Warehouse

    Riskin, Melissa L.; Reutter, David C.; Martin, Jeffrey D.; Mueller, David K.

    2018-04-10

    The data-quality objectives for samples collected at surface-water sites in the National Water-Quality Network include estimating the extent to which contamination, matrix effects, and measurement variability affect interpretation of environmental conditions. Quality-control samples provide insight into how well the samples collected at surface-water sites represent the true environmental conditions. Quality-control samples used in this program include field blanks, replicates, and field matrix spikes. This report describes the design for collection of these quality-control samples and the data management needed to properly identify these samples in the U.S. Geological Survey’s national database.

  6. Advanced strategies for quality control of Chinese medicines.

    PubMed

    Zhao, Jing; Ma, Shuang-Cheng; Li, Shao-Ping

    2018-01-05

    Quality control is always the critical issue for Chinese medicines (CMs) with their worldwide increasing use. Different from western medicine, CMs are usually considered that multiple constituents are responsible for the therapeutic effects. Therefore, quality control of CMs is a challenge. In 2011, the strategies for quantification, related to the markers, reference compounds and approaches, in quality control of CMs were reviewed (Li, et al., J. Pharm. Biomed. Anal., 2011, 55, 802-809). Since then, some new strategies have been proposed in these fields. Therefore, the review on the strategies for quality control of CMs should be updated to improve the safety and efficacy of CMs. Herein, novel strategies related to quality marker discovery, reference compound development and advanced approaches (focused on glyco-analysis) for quality control, during 2011-2016, were summarized and discussed. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. 30 CFR 28.30 - Quality control plans; filing requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Quality control plans; filing requirements. 28... PROTECTION FOR TRAILING CABLES IN COAL MINES Quality Control § 28.30 Quality control plans; filing... part, each applicant shall file with MSHA a proposed quality control plan which shall be designed to...

  8. 30 CFR 28.30 - Quality control plans; filing requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality control plans; filing requirements. 28... PROTECTION FOR TRAILING CABLES IN COAL MINES Quality Control § 28.30 Quality control plans; filing... part, each applicant shall file with MSHA a proposed quality control plan which shall be designed to...

  9. 30 CFR 28.30 - Quality control plans; filing requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PROTECTION FOR TRAILING CABLES IN COAL MINES Quality Control § 28.30 Quality control plans; filing... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Quality control plans; filing requirements. 28... part, each applicant shall file with MSHA a proposed quality control plan which shall be designed to...

  10. 30 CFR 28.30 - Quality control plans; filing requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... PROTECTION FOR TRAILING CABLES IN COAL MINES Quality Control § 28.30 Quality control plans; filing... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Quality control plans; filing requirements. 28... part, each applicant shall file with MSHA a proposed quality control plan which shall be designed to...

  11. 30 CFR 28.30 - Quality control plans; filing requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PROTECTION FOR TRAILING CABLES IN COAL MINES Quality Control § 28.30 Quality control plans; filing... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Quality control plans; filing requirements. 28... part, each applicant shall file with MSHA a proposed quality control plan which shall be designed to...

  12. Hydrologic response of streams restored with check dams in the Chiricahua Mountains, Arizona

    USGS Publications Warehouse

    Norman, Laura M.; Brinkerhoff, Fletcher C.; Gwilliam, Evan; Guertin, D. Phillip; Callegary, James B.; Goodrich, David C.; Nagler, Pamela L.; Gray, Floyd

    2016-01-01

    In this study, hydrological processes are evaluated to determine impacts of stream restoration in the West Turkey Creek, Chiricahua Mountains, southeast Arizona, during a summer-monsoon season (June–October of 2013). A paired-watershed approach was used to analyze the effectiveness of check dams to mitigate high flows and impact long-term maintenance of hydrologic function. One watershed had been extensively altered by the installation of numerous small check dams over the past 30 years, and the other was untreated (control). We modified and installed a new stream-gauging mechanism developed for remote areas, to compare the water balance and calculate rainfall–runoff ratios. Results show that even 30 years after installation, most of the check dams were still functional. The watershed treated with check dams has a lower runoff response to precipitation compared with the untreated, most notably in measurements of peak flow. Concerns that downstream flows would be reduced in the treated watershed, due to storage of water behind upstream check dams, were not realized; instead, flow volumes were actually higher overall in the treated stream, even though peak flows were dampened. We surmise that check dams are a useful management tool for reducing flow velocities associated with erosion and degradation and posit they can increase baseflow in aridlands.

  13. 31 CFR 240.12 - Processing of checks.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 31 Money and Finance:Treasury 2 2011-07-01 2011-07-01 false Processing of checks. 240.12 Section... ON THE UNITED STATES TREASURY General Provisions § 240.12 Processing of checks. (a) Federal Reserve... examination and will provide the presenting bank with a copy or image of the check. Such presenting bank must...

  14. 31 CFR 240.12 - Processing of checks.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 31 Money and Finance:Treasury 2 2013-07-01 2013-07-01 false Processing of checks. 240.12 Section... ON THE UNITED STATES TREASURY General Provisions § 240.12 Processing of checks. (a) Federal Reserve... examination and will provide the presenting bank with a copy or image of the check. Such presenting bank must...

  15. 31 CFR 240.12 - Processing of checks.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Processing of checks. 240.12 Section... ON THE UNITED STATES TREASURY General Provisions § 240.12 Processing of checks. (a) Federal Reserve... examination and will provide the presenting bank with a copy or image of the check. Such presenting bank must...

  16. 31 CFR 240.12 - Processing of checks.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 31 Money and Finance: Treasury 2 2014-07-01 2014-07-01 false Processing of checks. 240.12 Section... ON THE UNITED STATES TREASURY General Provisions § 240.12 Processing of checks. (a) Federal Reserve... examination and will provide the presenting bank with a copy or image of the check. Such presenting bank must...

  17. 31 CFR 240.12 - Processing of checks.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 31 Money and Finance:Treasury 2 2012-07-01 2012-07-01 false Processing of checks. 240.12 Section... ON THE UNITED STATES TREASURY General Provisions § 240.12 Processing of checks. (a) Federal Reserve... examination and will provide the presenting bank with a copy or image of the check. Such presenting bank must...

  18. 21 CFR 864.8625 - Hematology quality control mixture.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hematology quality control mixture. 864.8625 Section 864.8625 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... quality control mixture. (a) Identification. A hematology quality control mixture is a device used to...

  19. A quality control system for digital elevation data

    NASA Astrophysics Data System (ADS)

    Knudsen, Thomas; Kokkendorf, Simon; Flatman, Andrew; Nielsen, Thorbjørn; Rosenkranz, Brigitte; Keller, Kristian

    2015-04-01

    In connection with the introduction of a new version of the Danish national coverage Digital Elevation Model (DK-DEM), the Danish Geodata Agency has developed a comprehensive quality control (QC) and metadata production (MP) system for LiDAR point cloud data. The architecture of the system reflects its origin in a national mapping organization where raw data deliveries are typically outsourced to external suppliers. It also reflects a design decision of aiming at, whenever conceivable, doing full spatial coverage tests, rather than scattered sample checks. Hence, the QC procedure is split in two phases: A reception phase and an acceptance phase. The primary aim of the reception phase is to do a quick assessment of things that can typically go wrong, and which are relatively simple to check: Data coverage, data density, strip adjustment. If a data delivery passes the reception phase, the QC continues with the acceptance phase, which checks five different aspects of the point cloud data: Vertical accuracy Vertical precision Horizontal accuracy Horizontal precision Point classification correctness The vertical descriptors are comparatively simple to measure: The vertical accuracy is checked by direct comparison with previously surveyed patches. The vertical precision is derived from the observed variance on well defined flat surface patches. These patches are automatically derived from the road centerlines registered in FOT, the official Danish map data base. The horizontal descriptors are less straightforward to measure, since potential reference material for direct comparison is typically expected to be less accurate than the LiDAR data. The solution selected is to compare photogrammetrically derived roof centerlines from FOT with LiDAR derived roof centerlines. These are constructed by taking the 3D Hough transform of a point cloud patch defined by the photogrammetrical roof polygon. The LiDAR derived roof centerline is then the intersection line of the two primary

  20. FPGA-Based, Self-Checking, Fault-Tolerant Computers

    NASA Technical Reports Server (NTRS)

    Some, Raphael; Rennels, David

    2004-01-01

    identical programs in lock step, with comparison of their outputs to detect errors. It would also contain various cache local memory circuits, communication circuits, and configurable special-purpose processors that would use self-checking checkers. (The basic principle of the self-checking checker method is to utilize logic circuitry that generates error signals whenever there is an error in either the checker or the circuit being checked.) The memory system would comprise a main memory and a hardware-controlled check-pointing system (CPS) based on a buffer memory denoted the recovery cache. The main memory would contain random-access memory (RAM) chips and FPGAs that would, in addition to everything else, implement double-error-detecting and single-error-correcting memory functions to enable recovery from single-bit errors.

  1. Role of the check dam in land development on the Loess Plateau, China

    NASA Astrophysics Data System (ADS)

    Xu, Xiang-Zhou; Zhang, Luo-Hao; Zhu, Tongxin; Dang, Tian-Min; Zhang, Hong-Wu; Xu, Shi-Guo

    2017-04-01

    Check dam is one of the most effective measures to reduce flow connectivity, which can retain soil and water, and increase land productivity. More than 100,000 check dams have been built on the Loess Plateau since 1950s. However, quantifying the effect of check dams on water resources and water environments remains a challenge. In this study, an in-depth field investigation together with a credible statistical analysis was carried out in two representative catchments on the Loess Plateau, Nanxiaohegou Catchment and Jiuyuangou Catchment, to assess the effectiveness of check dams in soil, water and nutrients conservation. The results show: (1) Check dam plays an important role in conserving water, soil, and nutrients on the Loess Plateau. About half of the total transported water and more than 80 % of the total transported soil and nutrients, had been locally retained in the selected catchments. Hence check dams had a significant benefit to improve soil fertility in the small watersheds, and reducing water pollution downstream of dams. (2) Compared to terrace farmlands, forest lands and grasslands, check-dam lands were much more important in conserving water, soil and nutrients in the catchments. Nearly 50% of the reduced water and more than 70% of the stored soil and nutrients in the study catchments were solely retained by the check dams, whereas the area of the dam lands was less than 7% of the total conservation land area. (3) Check dams are still effective in large storms even if dams were damaged by floods. It is often assumed that check dams could only retain sediment in small flood events whereas most of the stored soil may be washed out as the dams may be destroyed in a disastrous flood. Furthermore, if a major check dam, namely the key project dam, was built in the gully outlet, the flood could be controlled, and thereupon the dam-break can be also avoided. We suggest that a compensation and incentive policy be implemented on dam building to realize the

  2. Cellular Strategies of Protein Quality Control

    PubMed Central

    Chen, Bryan; Retzlaff, Marco; Roos, Thomas; Frydman, Judith

    2011-01-01

    Eukaryotic cells must contend with a continuous stream of misfolded proteins that compromise the cellular protein homeostasis balance and jeopardize cell viability. An elaborate network of molecular chaperones and protein degradation factors continually monitor and maintain the integrity of the proteome. Cellular protein quality control relies on three distinct yet interconnected strategies whereby misfolded proteins can either be refolded, degraded, or delivered to distinct quality control compartments that sequester potentially harmful misfolded species. Molecular chaperones play a critical role in determining the fate of misfolded proteins in the cell. Here, we discuss the spatial and temporal organization of cellular quality control strategies and their implications for human diseases linked to protein misfolding and aggregation. PMID:21746797

  3. 21 CFR 211.22 - Responsibilities of quality control unit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 4 2011-04-01 2011-04-01 false Responsibilities of quality control unit. 211.22... Personnel § 211.22 Responsibilities of quality control unit. (a) There shall be a quality control unit that... have been fully investigated. The quality control unit shall be responsible for approving or rejecting...

  4. 21 CFR 211.22 - Responsibilities of quality control unit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Responsibilities of quality control unit. 211.22... Personnel § 211.22 Responsibilities of quality control unit. (a) There shall be a quality control unit that... have been fully investigated. The quality control unit shall be responsible for approving or rejecting...

  5. 40 CFR 81.112 - Charleston Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Regions § 81.112 Charleston Intrastate Air Quality Control Region. The Charleston Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... Quality Control Region: Region 1. 81.107Greenwood Intrastate Air Quality Control Region: Region 2. 81...

  6. 40 CFR 81.112 - Charleston Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Regions § 81.112 Charleston Intrastate Air Quality Control Region. The Charleston Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... Quality Control Region: Region 1. 81.107Greenwood Intrastate Air Quality Control Region: Region 2. 81...

  7. 7 CFR 275.21 - Quality control review reports.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 4 2011-01-01 2011-01-01 false Quality control review reports. 275.21 Section 275.21... Reporting on Program Performance § 275.21 Quality control review reports. (a) General. Each State agency shall submit reports on the performance of quality control reviews in accordance with the requirements...

  8. A check valve controlled laser-induced microjet for uniform transdermal drug delivery

    NASA Astrophysics Data System (ADS)

    Ham, Hwi-chan; Jang, Hun-jae; Yoh, Jack J.

    2017-12-01

    A narrow nozzle ejects a microjet of 150 μm in diameter with a velocity of 140 m/s a by the laser-induced bubble expansion in the designed injector. The pulsed form of the driving force at a period of 10 Hz from the connected Er:YAG laser makes it possible for multiple microjet ejections aimed at delivery of drugs into a skin target. The pulsed actuation of the microjet generation is however susceptible to the air leak which can cause the outside air to enter into the momentarily de-pressurized nozzle, leading to a significant reduction of the microjet speed during the pulsed administering of the drug. In the present study, we designed a ball-check valve injector which is less prone to an unwanted air build up inside the nozzle by controlling the nozzle pressure to remain above ambient pressure at all times. The new device is rigorously compared against the reported performance of the previous injector and has shown to maintain about 97% of the initial microjet speed regardless of the number of shots administered; likewise, the drug penetration depth into a porcine skin is improved to 1.5 to 2.25 times the previously reported penetration depths.

  9. 40 CFR 81.88 - Billings Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Regions § 81.88 Billings Intrastate Air Quality Control Region. The Metropolitan Billings Intrastate Air Quality Control Region (Montana) has been renamed the Billings Intrastate Air Quality Control... to by Montana authorities as follows: Sec. 481.168Great Falls Intrastate Air Quality Control Region...

  10. 40 CFR 81.88 - Billings Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Regions § 81.88 Billings Intrastate Air Quality Control Region. The Metropolitan Billings Intrastate Air Quality Control Region (Montana) has been renamed the Billings Intrastate Air Quality Control... to by Montana authorities as follows: Sec. 481.168Great Falls Intrastate Air Quality Control Region...

  11. Assessing the Implementation Fidelity of Check-In Check-Out Behavioral Interventions in Elementary and Middle Schools

    ERIC Educational Resources Information Center

    Ruiz, María Isolina; Smith, Traci N.; Naquin, Gale M.; Morgan-D'Atrio, Cynthia; Dellinger, Amy B.

    2014-01-01

    Implementation fidelity is crucial to the success of behavioral interventions. However, measuring and maintaining intervention implementation fidelity in schools' natural settings can be challenging. This article reports findings from a study examining the implementation fidelity of check-in check-out interventions at an urban school district…

  12. Mobile Attendance Checking System on Android Platform for Kazakhstani University

    NASA Astrophysics Data System (ADS)

    Saparkhojayev, N.; Shakhov, E.; Mailybayev, Y.

    2016-04-01

    In the 21st century-the century of Information Technology, it is difficult to imagine life without any gadgets: phones, tablets, computers, laptops, and so on. Today, smartphones and tablets are becoming popular, and thus their operating systems become popular too. Android is designed for low-power devices that run on battery power at full capacity, using all of its services, such as cameras, lights, GPS navigation, Wi-Fi, etc. In Kazakhstani universities, the process of checking students’ attendance is one of the important issues, because final grade evaluation of students is based on their total number of appearances and their grades during the whole semester. This raises the question of having some tool to control students’ attendance. There are many possible ways of controlling attendance: there are many examples when universities prefer to control attendance by the use of paper sheet, and some universities prefer to use two-stage way of controlling attendance: firstly, teachers and professors use paper sheet for checking students’ attendance and after this, they fill out these information into a system manually. However, this is not an efficient way since there will be spent much of time for calling students names and putting marks like “presence” or “absence” if the class is a lecture class, and in this class at least 5 groups are presented. Furthermore, some students may call his/her friend as “presence” nevertheless to the fact that this student is currently absent. After taking into consideration all these issues and the fact that many gadgets use Android platform, authors of the following research paper decided to create a mobile system that makes easier to check students’ attendance automatically, and this system is implemented in Almaty Management University, Kazakhstan. The system is based on Android platform, and in this paper, details of this system are presented.

  13. Addressing Dynamic Issues of Program Model Checking

    NASA Technical Reports Server (NTRS)

    Lerda, Flavio; Visser, Willem

    2001-01-01

    Model checking real programs has recently become an active research area. Programs however exhibit two characteristics that make model checking difficult: the complexity of their state and the dynamic nature of many programs. Here we address both these issues within the context of the Java PathFinder (JPF) model checker. Firstly, we will show how the state of a Java program can be encoded efficiently and how this encoding can be exploited to improve model checking. Next we show how to use symmetry reductions to alleviate some of the problems introduced by the dynamic nature of Java programs. Lastly, we show how distributed model checking of a dynamic program can be achieved, and furthermore, how dynamic partitions of the state space can improve model checking. We support all our findings with results from applying these techniques within the JPF model checker.

  14. 27 CFR 70.101 - Bad checks.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... paid as a penalty by the person who tendered such check, upon notice and demand, in the same manner as... is less than $500, the penalty under this section shall be $5 or the amount of such check, whichever...

  15. 27 CFR 70.101 - Bad checks.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... paid as a penalty by the person who tendered such check, upon notice and demand, in the same manner as... is less than $500, the penalty under this section shall be $5 or the amount of such check, whichever...

  16. Data Quality Control and Maintenance for the Qweak Experiment

    NASA Astrophysics Data System (ADS)

    Heiner, Nicholas; Spayde, Damon

    2014-03-01

    The Qweak collaboration seeks to quantify the weak charge of a proton through the analysis of the parity-violating electron asymmetry in elastic electron-proton scattering. The asymmetry is calculated by measuring how many electrons deflect from a hydrogen target at the chosen scattering angle for aligned and anti-aligned electron spins, then evaluating the difference between the numbers of deflections that occurred for both polarization states. The weak charge can then be extracted from this data. Knowing the weak charge will allow us to calculate the electroweak mixing angle for the particular Q2 value of the chosen electrons, which the Standard Model makes a firm prediction for. Any significant deviation from this prediction would be a prime indicator of the existence of physics beyond what the Standard Model describes. After the experiment was conducted at Jefferson Lab, collected data was stored within a MySQL database for further analysis. I will present an overview of the database and its functions as well as a demonstration of the quality checks and maintenance performed on the data itself. These checks include an analysis of errors occurring throughout the experiment, specifically data acquisition errors within the main detector array, and an analysis of data cuts.

  17. Radiation Safety and Quality Assurance in North American Dental Schools.

    ERIC Educational Resources Information Center

    Farman, Allan G.; Hines, Vickie G.

    1986-01-01

    A survey of dental schools that revealed processing quality control and routine maintenance checks on x-ray generators are being carried out in a timely manner is discussed. However, methods for reducing patient exposure to radiation are not being fully implemented, and some dental students are being exposed to x-rays. (Author/MLW)

  18. 14 CFR 135.339 - Initial and transition training and checking: Check airmen (aircraft), check airmen (simulator).

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... an aircraft, in a flight simulator, or in a flight training device. This paragraph applies after... accomplished in full or in part in flight, in a flight simulator, or in a flight training device, as appropriate. (g) The initial and transition flight training for check airmen (simulator) must include the...

  19. 14 CFR 135.339 - Initial and transition training and checking: Check airmen (aircraft), check airmen (simulator).

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... an aircraft, in a flight simulator, or in a flight training device. This paragraph applies after... accomplished in full or in part in flight, in a flight simulator, or in a flight training device, as appropriate. (g) The initial and transition flight training for check airmen (simulator) must include the...

  20. 14 CFR 135.339 - Initial and transition training and checking: Check airmen (aircraft), check airmen (simulator).

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... an aircraft, in a flight simulator, or in a flight training device. This paragraph applies after... accomplished in full or in part in flight, in a flight simulator, or in a flight training device, as appropriate. (g) The initial and transition flight training for check airmen (simulator) must include the...

  1. 14 CFR 135.339 - Initial and transition training and checking: Check airmen (aircraft), check airmen (simulator).

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... an aircraft, in a flight simulator, or in a flight training device. This paragraph applies after... accomplished in full or in part in flight, in a flight simulator, or in a flight training device, as appropriate. (g) The initial and transition flight training for check airmen (simulator) must include the...

  2. 14 CFR 135.339 - Initial and transition training and checking: Check airmen (aircraft), check airmen (simulator).

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... an aircraft, in a flight simulator, or in a flight training device. This paragraph applies after... accomplished in full or in part in flight, in a flight simulator, or in a flight training device, as appropriate. (g) The initial and transition flight training for check airmen (simulator) must include the...

  3. 7 CFR 58.141 - Alternate quality control program.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Alternate quality control program. 58.141 Section 58... Service 1 Quality Specifications for Raw Milk § 58.141 Alternate quality control program. When a plant has in operation an acceptable quality program, at the producer level, which is approved by the...

  4. 21 CFR 111.105 - What must quality control personnel do?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 2 2011-04-01 2011-04-01 false What must quality control personnel do? 111.105... for Quality Control § 111.105 What must quality control personnel do? Quality control personnel must... manufacturing record. To do so, quality control personnel must perform operations that include: (a) Approving or...

  5. Who benefit from school doctors' health checks: a prospective study of a screening method.

    PubMed

    Nikander, Kirsi; Kosola, Silja; Kaila, Minna; Hermanson, Elina

    2018-06-27

    School health services provide an excellent opportunity for the detection and treatment of children at risk of later health problems. However, the optimal use of school doctors' skills and expertise remains unknown. Furthermore, no validated method for screening children for school doctors' assessments exists. The aims of the study are 1) to evaluate the benefits or harm of school doctors' routine health checks in primary school grades 1 and 5 (at ages 7 and 11) and 2) to explore whether some of the school doctors' routine health checks can be omitted using study questionnaires. This is a prospective, multicenter observational study conducted in four urban municipalities in Southern Finland by comparing the need for a school doctor's assessment to the benefit gained from it. We will recruit a random sample of 1050 children from 21 schools from primary school grades 1 and 5. Before the school doctor's health check, parents, nurses and teachers fill a study questionnaire to identify any potential concerns about each child. Doctors, blinded to the questionnaire responses, complete an electronic report after the appointment, including given instructions and follow-up plans. The child, parent, doctor and researchers assess the benefit of the health check. The researchers compare the need for a doctor's appointment to the benefit gained from it. At one year after the health check, we will analyze the implementation of the doctors' interventions and follow-up plans. The study will increase our knowledge of the benefits of school doctors' routine health checks and assess the developed screening method. We hypothesize that targeting the health checks to the children in greatest need would increase the quality of school health services. ClinicalTrials.gov Identifier: NCT03178331 , date of registration June 6 th 2017.

  6. Turbomachinery Design Quality Checks to Avoid Friction Induced Structural Failure

    NASA Technical Reports Server (NTRS)

    Moore, Jerry H.

    1999-01-01

    A unique configuration of the P&W SSME Alternate Fuel Turbopump turbine disk/blade assembly, combined with a severe thermal environment, resulted in several structural anomalies that were driven by frictional contact forces. Understanding the mechanics of these problems provides new quality checks for future turbo machinery designs. During development testing in 1997 of the SSME alternate fuel turbopump at Stennis Space Center, several potentially serious problems surfaced with the turbine disk/blade assembly that had not been experienced in extensive earlier testing. Changes to the operational thermal environment were noted based on analytical prediction of modifications that affected performance and on stationary thermal measurements adjacent to the rotor assembly. A detailed structural investigation was required to reveal the mechanism of distress induced by the change. The turbine disk experienced cracking in several locations due to increased thermal gradient induced stress during start and shutdown transients. This was easily predictable using standard analysis procedures and expected once the thermal environment was characterized. What was not expected was the curling of a piston ring used for blade axial retention in the disk, indentation of the axial face of the blade attachment by a spacer separating the first and second stage blades, and most significantly, galling and cracking of the blade root attachment that could have resulted in blade release. Past experience, in gas turbine environments, set a precedent of never relying on friction for help and to evaluate it only in specific instances where it was obvious that it would degrade capability. In each of the three cases above, friction proved to be a determining factor that pushed the components into an unsatisfactory mode of operation. The higher than expected temperatures and rapid thermal transients combined with friction to move beyond past experience. The turbine disk/blade assembly configuration

  7. Lot quality assurance sampling of sputum acid-fast bacillus smears for assessing sputum smear microscopy centers.

    PubMed

    Selvakumar, N; Murthy, B N; Prabhakaran, E; Sivagamasundari, S; Vasanthan, Samuel; Perumal, M; Govindaraju, R; Chauhan, L S; Wares, Fraser; Santha, T; Narayanan, P R

    2005-02-01

    Assessment of 12 microscopy centers in a tuberculosis unit by blinded checking of eight sputum smears selected by using a lot quality assurance sampling (LQAS) method and by unblinded checking of all positive and five negative slides, among the slides examined in a month in a microscopy centre, revealed that the LQAS method can be implemented in the field to monitor the performance of acid-fast bacillus microscopy centers in national tuberculosis control programs.

  8. Theoretical approach to society-wide environmental quality control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ayano, K.

    1982-01-01

    The study outlines the basis for a theory of societal control of environmental quality in the US based on the concepts and philosophy of company-wide quality control which has developed in Japan as a cross-disciplinary approach to problem-solving in the industrial realm. The basic concepts are: 1) every member of society, as a producer of environmental products and services for future generations, in principle has the responsibility to control the quality of his output; 2) environment quality is the quality of life, or the fitness of use of environment for humans; and 3) societal control is any activity necessary formore » quality production of environmental products and services continuously or in the long run. A motivator-hygiene theory of environmental quality is identified, and a proposal is made that the policy provision must be formulated differently between those aimed at hygiene factors of environmental quality and those aimed at motivators, the former in a collectivistic manner, the latter as an individual problem. The concept of societal cost of environmental quality is introduced. Based on the motivator-hygiene theory of environmental quality, the collectivistic and individual approaches are differentiated and discussed.« less

  9. Computational Fact Checking from Knowledge Networks

    PubMed Central

    Ciampaglia, Giovanni Luca; Shiralkar, Prashant; Rocha, Luis M.; Bollen, Johan; Menczer, Filippo; Flammini, Alessandro

    2015-01-01

    Traditional fact checking by expert journalists cannot keep up with the enormous volume of information that is now generated online. Computational fact checking may significantly enhance our ability to evaluate the veracity of dubious information. Here we show that the complexities of human fact checking can be approximated quite well by finding the shortest path between concept nodes under properly defined semantic proximity metrics on knowledge graphs. Framed as a network problem this approach is feasible with efficient computational techniques. We evaluate this approach by examining tens of thousands of claims related to history, entertainment, geography, and biographical information using a public knowledge graph extracted from Wikipedia. Statements independently known to be true consistently receive higher support via our method than do false ones. These findings represent a significant step toward scalable computational fact-checking methods that may one day mitigate the spread of harmful misinformation. PMID:26083336

  10. Network design and quality checks in automatic orientation of close-range photogrammetric blocks.

    PubMed

    Dall'Asta, Elisa; Thoeni, Klaus; Santise, Marina; Forlani, Gianfranco; Giacomini, Anna; Roncella, Riccardo

    2015-04-03

    Due to the recent improvements of automatic measurement procedures in photogrammetry, multi-view 3D reconstruction technologies are becoming a favourite survey tool. Rapidly widening structure-from-motion (SfM) software packages offer significantly easier image processing workflows than traditional photogrammetry packages. However, while most orientation and surface reconstruction strategies will almost always succeed in any given task, estimating the quality of the result is, to some extent, still an open issue. An assessment of the precision and reliability of block orientation is necessary and should be included in every processing pipeline. Such a need was clearly felt from the results of close-range photogrammetric surveys of in situ full-scale and laboratory-scale experiments. In order to study the impact of the block control and the camera network design on the block orientation accuracy, a series of Monte Carlo simulations was performed. Two image block configurations were investigated: a single pseudo-normal strip and a circular highly-convergent block. The influence of surveying and data processing choices, such as the number and accuracy of the ground control points, autofocus and camera calibration was investigated. The research highlights the most significant aspects and processes to be taken into account for adequate in situ and laboratory surveys, when modern SfM software packages are used, and evaluates their effect on the quality of the results of the surface reconstruction.

  11. Toward improved design of check dam systems: A case study in the Loess Plateau, China

    NASA Astrophysics Data System (ADS)

    Pal, Debasish; Galelli, Stefano; Tang, Honglei; Ran, Qihua

    2018-04-01

    Check dams are one of the most common strategies for controlling sediment transport in erosion prone areas, along with soil and water conservation measures. However, existing mathematical models that simulate sediment production and delivery are often unable to simulate how the storage capacity of check dams varies with time. To explicitly account for this process-and to support the design of check dam systems-we developed a modelling framework consisting of two components, namely (1) the spatially distributed Soil Erosion and Sediment Delivery Model (WaTEM/SEDEM), and (2) a network-based model of check dam storage dynamics. The two models are run sequentially, with the second model receiving the initial sediment input to check dams from WaTEM/SEDEM. The framework is first applied to Shejiagou catchment, a 4.26 km2 area located in the Loess Plateau, China, where we study the effect of the existing check dam system on sediment dynamics. Results show that the deployment of check dams altered significantly the sediment delivery ratio of the catchment. Furthermore, the network-based model reveals a large variability in the life expectancy of check dams and abrupt changes in their filling rates. The application of the framework to six alternative check dam deployment scenarios is then used to illustrate its usefulness for planning purposes, and to derive some insights on the effect of key decision variables, such as the number, size, and site location of check dams. Simulation results suggest that better performance-in terms of life expectancy and sediment delivery ratio-could have been achieved with an alternative deployment strategy.

  12. Evaluating the accuracy of technicians and pharmacists in checking unit dose medication cassettes.

    PubMed

    Ambrose, Peter J; Saya, Frank G; Lovett, Larry T; Tan, Sandy; Adams, Dale W; Shane, Rita

    2002-06-15

    The accuracy rates of board-registered pharmacy technicians and pharmacists in checking unit dose medication cassettes in the inpatient setting at two separate institutions were examined. Cedars-Sinai Medical Center and Long Beach Memorial Medical Center, both in Los Angeles county, petitioned the California State Board of Pharmacy to approve a waiver of the California Code of Regulations to conduct an experimental program to compare the accuracy of unit dose medication cassettes checked by pharmacists with that of cassettes checked by trained, certified pharmacy technicians. The study consisted of three parts: assessing pharmacist baseline checking accuracy (Phase I), developing a technician-training program and certifying technicians who completed the didactic and practical training (Phase II), and evaluating the accuracy of certified technicians checking unit dose medication cassettes as a daily function (Phase III). Twenty-nine pharmacists and 41 technicians (3 of whom were pharmacy interns) participated in the study. Of the technicians, all 41 successfully completed the didactic and practical training, 39 successfully completed the audits and became certified checkers, and 2 (including 1 of the interns) did not complete the certification audits because they were reassigned to another work area or had resigned. In Phase II, the observed accuracy rate and its lower confidence limit exceeded the predetermined minimum requirement of 99.8% for a certified checker. The mean accuracy rates for technicians were identical at the two institutions (p = 1.0). The difference in mean accuracy rates between pharmacists (99.52%; 95% confidence interval [CI] 99.44-99.58%) and technicians, (99.89%; 95% CI 99.87-99.90%) was significant (p < 0.0001). Inpatient technicians who had been trained and certified in a closely supervised program that incorporated quality assurance mechanisms could safely and accurately check unit dose medication cassettes filled by other technicians.

  13. SU8 diaphragm micropump with monolithically integrated cantilever check valves.

    PubMed

    Ezkerra, Aitor; Fernández, Luis José; Mayora, Kepa; Ruano-López, Jesús Miguel

    2011-10-07

    This paper presents a SU8 unidirectional diaphragm micropump with embedded out-of-plane cantilever check valves. The device represents a reliable and low-cost solution for integration of microfluidic control in lab-on-a-chip devices. Its planar architecture allows monolithic definition of its components in a single step and potential integration with previously reported PCR, electrophoresis and flow-sensing SU8 microdevices. Pneumatic actuation is applied on a PDMS diaphragm, which is bonded to the SU8 body at wafer level, further enhancing its integration and mass production capabilities. The cantilever check valves move synchronously with the diaphragm, feature fast response (10ms), low dead volume (86nl) and a 94% flow blockage up to 300kPa. The micropump achieves a maximum flow rate of 177 μl min(-1) at 6 Hz and 200 kPa with an effective area of 10 mm(2). The device is reliable, self-priming and tolerant to particles and big bubbles. To the knowledge of the authors, this is the first micropump in SU8 with monolithically integrated cantilever check valves.

  14. Quality Control in Higher Education.

    ERIC Educational Resources Information Center

    Hogarth, Charles P.

    The status of quality control in U.S. higher education is discussed with an overview of the functions and structure of public and private colleges and universities. The book is divided into seven chapters: (1) outside controls (accrediting groups, governmental groups and other groups); (2) structure (board of control, president, organization); (3)…

  15. Check valve installation in pilot operated relief valve prevents reverse pressurization

    NASA Technical Reports Server (NTRS)

    Oswalt, L.

    1966-01-01

    Two check valves prevent reverse flow through pilot-operated relief valves of differential area piston design. Title valves control pressure flow to ensure that the piston dome pressure is always at least as great as the main relief valve discharge pressure.

  16. 31 CFR 245.8 - Receipt or recovery of original check.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Receipt or recovery of original check... CHECKS § 245.8 Receipt or recovery of original check. (a) If the original check is received or recovered... of instructions with respect to the negotiability of such check. (b) If the original check is...

  17. 36 CFR 504.12 - Items to be checked.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Section 504.12 Parks, Forests, and Public Property SMITHSONIAN INSTITUTION RULES AND REGULATIONS GOVERNING SMITHSONIAN INSTITUTION BUILDINGS AND GROUNDS § 504.12 Items to be checked. Umbrellas, canes (not needed to... to be checked in buildings where checking facilities are provided. ...

  18. Quality Control Technician.

    ERIC Educational Resources Information Center

    Ohio State Univ., Columbus. Center on Education and Training for Employment.

    This document contains 18 units to consider for use in a tech prep competency profile for the occupation of quality control technician. All the units listed will not necessarily apply to every situation or tech prep consortium, nor will all the competencies within each unit be appropriate. Several units appear within each specific occupation and…

  19. Annual Check-up

    MedlinePlus

    ... Guides Quizzes Parents About Us Donate General Health Sexual Health Medical Conditions Nutrition & Fitness Emotional Health Annual Check- ... re under the age of 18. Issues about sexual health, HIV, and STIs will be kept confidential. How ...

  20. MO-F-CAMPUS-T-04: Implementation of a Standardized Monthly Quality Check for Linac Output Management in a Large Multi-Site Clinic

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, H; Yi, B; Prado, K

    2015-06-15

    Purpose: This work is to investigate the feasibility of a standardized monthly quality check (QC) of LINAC output determination in a multi-site, multi-LINAC institution. The QC was developed to determine individual LINAC output using the same optimized measurement setup and a constant calibration factor for all machines across the institution. Methods: The QA data over 4 years of 7 Varian machines over four sites, were analyzed. The monthly output constancy checks were performed using a fixed source-to-chamber-distance (SCD), with no couch position adjustment throughout the measurement cycle for all the photon energies: 6 and 18MV, and electron energies: 6, 9,more » 12, 16 and 20 MeV. The constant monthly output calibration factor (Nconst) was determined by averaging the machines’ output data, acquired with the same monthly ion chamber. If a different monthly ion chamber was used, Nconst was then re-normalized to consider its different NDW,Co-60. Here, the possible changes of Nconst over 4 years have been tracked, and the precision of output results based on this standardized monthly QA program relative to the TG-51 calibration for each machine was calculated. Any outlier of the group was investigated. Results: The possible changes of Nconst varied between 0–0.9% over 4 years. The normalization of absorbed-dose-to-water calibration factors corrects for up to 3.3% variations of different monthly QA chambers. The LINAC output precision based on this standardized monthly QC relative to the TG-51 output calibration is within 1% for 6MV photon energy and 2% for 18MV and all the electron energies. A human error in one TG-51 report was found through a close scrutiny of outlier data. Conclusion: This standardized QC allows for a reasonably simplified, precise and robust monthly LINAC output constancy check, with the increased sensitivity needed to detect possible human errors and machine problems.« less

  1. 40 CFR 81.77 - Puerto Rico Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 17 2011-07-01 2011-07-01 false Puerto Rico Air Quality Control Region... PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.77 Puerto Rico Air Quality Control Region. The Puerto Rico Air Quality Control Region...

  2. 40 CFR 81.77 - Puerto Rico Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Puerto Rico Air Quality Control Region... PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.77 Puerto Rico Air Quality Control Region. The Puerto Rico Air Quality Control Region...

  3. 40 CFR 81.77 - Puerto Rico Air Quality Control Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 18 2012-07-01 2012-07-01 false Puerto Rico Air Quality Control Region... PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.77 Puerto Rico Air Quality Control Region. The Puerto Rico Air Quality Control Region...

  4. 40 CFR 81.77 - Puerto Rico Air Quality Control Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 18 2013-07-01 2013-07-01 false Puerto Rico Air Quality Control Region... PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.77 Puerto Rico Air Quality Control Region. The Puerto Rico Air Quality Control Region...

  5. 14 CFR 121.413 - Initial and transition training and checking requirements: Check airmen (airplane), check airmen...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... accomplished in part or in full in an airplane, in a flight simulator, or in a flight training device. This... accomplished in full or in part in flight, in a flight simulator, or in a flight training device, as appropriate. (g) The initial and transition flight training for check airmen (simulator) must include the...

  6. 14 CFR 121.413 - Initial and transition training and checking requirements: Check airmen (airplane), check airmen...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... accomplished in part or in full in an airplane, in a flight simulator, or in a flight training device. This... accomplished in full or in part in flight, in a flight simulator, or in a flight training device, as appropriate. (g) The initial and transition flight training for check airmen (simulator) must include the...

  7. 14 CFR 121.413 - Initial and transition training and checking requirements: Check airmen (airplane), check airmen...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... accomplished in part or in full in an airplane, in a flight simulator, or in a flight training device. This... accomplished in full or in part in flight, in a flight simulator, or in a flight training device, as appropriate. (g) The initial and transition flight training for check airmen (simulator) must include the...

  8. 14 CFR 121.413 - Initial and transition training and checking requirements: Check airmen (airplane), check airmen...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... accomplished in part or in full in an airplane, in a flight simulator, or in a flight training device. This... accomplished in full or in part in flight, in a flight simulator, or in a flight training device, as appropriate. (g) The initial and transition flight training for check airmen (simulator) must include the...

  9. Improving spot-scanning proton therapy patient specific quality assurance with HPlusQA, a second-check dose calculation engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mackin, Dennis; Li, Yupeng; Taylor, Michael B.

    Purpose: The purpose of this study was to validate the use of HPlusQA, spot-scanning proton therapy (SSPT) dose calculation software developed at The University of Texas MD Anderson Cancer Center, as second-check dose calculation software for patient-specific quality assurance (PSQA). The authors also showed how HPlusQA can be used within the current PSQA framework.Methods: The authors compared the dose calculations of HPlusQA and the Eclipse treatment planning system with 106 planar dose measurements made as part of PSQA. To determine the relative performance and the degree of correlation between HPlusQA and Eclipse, the authors compared calculated with measured point doses.more » Then, to determine how well HPlusQA can predict when the comparisons between Eclipse calculations and the measured dose will exceed tolerance levels, the authors compared gamma index scores for HPlusQA versus Eclipse with those of measured doses versus Eclipse. The authors introduce the αβγ transformation as a way to more easily compare gamma scores.Results: The authors compared measured and calculated dose planes using the relative depth, z/R × 100%, where z is the depth of the measurement and R is the proton beam range. For relative depths than less than 80%, both Eclipse and HPlusQA calculations were within 2 cGy of dose measurements on average. When the relative depth was greater than 80%, the agreement between the calculations and measurements fell to 4 cGy. For relative depths less than 10%, the Eclipse and HPlusQA dose discrepancies showed a negative correlation, −0.21. Otherwise, the correlation between the dose discrepancies was positive and as large as 0.6. For the dose planes in this study, HPlusQA correctly predicted when Eclipse had and had not calculated the dose to within tolerance 92% and 79% of the time, respectively. In 4 of 106 cases, HPlusQA failed to predict when the comparison between measurement and Eclipse's calculation had exceeded the tolerance levels of

  10. Improving spot-scanning proton therapy patient specific quality assurance with HPlusQA, a second-check dose calculation engine.

    PubMed

    Mackin, Dennis; Li, Yupeng; Taylor, Michael B; Kerr, Matthew; Holmes, Charles; Sahoo, Narayan; Poenisch, Falk; Li, Heng; Lii, Jim; Amos, Richard; Wu, Richard; Suzuki, Kazumichi; Gillin, Michael T; Zhu, X Ronald; Zhang, Xiaodong

    2013-12-01

    The purpose of this study was to validate the use of HPlusQA, spot-scanning proton therapy (SSPT) dose calculation software developed at The University of Texas MD Anderson Cancer Center, as second-check dose calculation software for patient-specific quality assurance (PSQA). The authors also showed how HPlusQA can be used within the current PSQA framework. The authors compared the dose calculations of HPlusQA and the Eclipse treatment planning system with 106 planar dose measurements made as part of PSQA. To determine the relative performance and the degree of correlation between HPlusQA and Eclipse, the authors compared calculated with measured point doses. Then, to determine how well HPlusQA can predict when the comparisons between Eclipse calculations and the measured dose will exceed tolerance levels, the authors compared gamma index scores for HPlusQA versus Eclipse with those of measured doses versus Eclipse. The authors introduce the αβγ transformation as a way to more easily compare gamma scores. The authors compared measured and calculated dose planes using the relative depth, z∕R × 100%, where z is the depth of the measurement and R is the proton beam range. For relative depths than less than 80%, both Eclipse and HPlusQA calculations were within 2 cGy of dose measurements on average. When the relative depth was greater than 80%, the agreement between the calculations and measurements fell to 4 cGy. For relative depths less than 10%, the Eclipse and HPlusQA dose discrepancies showed a negative correlation, -0.21. Otherwise, the correlation between the dose discrepancies was positive and as large as 0.6. For the dose planes in this study, HPlusQA correctly predicted when Eclipse had and had not calculated the dose to within tolerance 92% and 79% of the time, respectively. In 4 of 106 cases, HPlusQA failed to predict when the comparison between measurement and Eclipse's calculation had exceeded the tolerance levels of 3% for dose and 3 mm for

  11. 21 CFR 111.105 - What must quality control personnel do?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What must quality control personnel do? 111.105..., LABELING, OR HOLDING OPERATIONS FOR DIETARY SUPPLEMENTS Production and Process Control System: Requirements for Quality Control § 111.105 What must quality control personnel do? Quality control personnel must...

  12. A Total Quality-Control Plan with Right-Sized Statistical Quality-Control.

    PubMed

    Westgard, James O

    2017-03-01

    A new Clinical Laboratory Improvement Amendments option for risk-based quality-control (QC) plans became effective in January, 2016. Called an Individualized QC Plan, this option requires the laboratory to perform a risk assessment, develop a QC plan, and implement a QC program to monitor ongoing performance of the QC plan. Difficulties in performing a risk assessment may limit validity of an Individualized QC Plan. A better alternative is to develop a Total QC Plan including a right-sized statistical QC procedure to detect medically important errors. Westgard Sigma Rules provides a simple way to select the right control rules and the right number of control measurements. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. 32 CFR 635.6 - Name checks.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... with AR 340-21. (b) Checks will be accomplished by a review of the COPS MPRS. Information will be... agencies for counterintelligence purposes. (d) COPS MPRS is a database, which will contain all military police reports filed worldwide. Authorized users of COPS MPRS can conduct name checks for criminal...

  14. 32 CFR 635.6 - Name checks.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... with AR 340-21. (b) Checks will be accomplished by a review of the COPS MPRS. Information will be... agencies for counterintelligence purposes. (d) COPS MPRS is a database, which will contain all military police reports filed worldwide. Authorized users of COPS MPRS can conduct name checks for criminal...

  15. 32 CFR 635.6 - Name checks.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... with AR 340-21. (b) Checks will be accomplished by a review of the COPS MPRS. Information will be... agencies for counterintelligence purposes. (d) COPS MPRS is a database, which will contain all military police reports filed worldwide. Authorized users of COPS MPRS can conduct name checks for criminal...

  16. 46 CFR 10.214 - Security Check.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 1 2011-10-01 2011-10-01 false Security Check. 10.214 Section 10.214 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY MERCHANT MARINE OFFICERS AND SEAMEN MERCHANT MARINER CREDENTIAL General Requirements for All Merchant Mariner Credentials § 10.214 Security Check. Until April 15, 2009...

  17. 46 CFR 10.214 - Security Check.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Security Check. 10.214 Section 10.214 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY MERCHANT MARINE OFFICERS AND SEAMEN MERCHANT MARINER CREDENTIAL General Requirements for All Merchant Mariner Credentials § 10.214 Security Check. Until April 15, 2009...

  18. Quality assurance and ergonomics in the mammography department.

    PubMed

    Reynolds, April

    2014-01-01

    Quality assurance (QA) in mammography is a system of checks that helps ensure the proper functioning of imaging equipment and processes. Ergonomics is a scientific approach to arranging the work environment to reduce the risk of work-related injuries while increasing staff productivity and job satisfaction. This article reviews both QA and ergonomics in mammography and explains how they work together to create a safe and healthy environment for radiologic technologists and their patients. QA and quality control requirements in mammography are discussed, along with ergonomic best practices in the mammography setting.

  19. Found Poems, Member Checking and Crises of Representation

    ERIC Educational Resources Information Center

    Reilly, Rosemary C.

    2013-01-01

    In order to establish veracity, qualitative researchers frequently rely on member checks to insure credibility by giving participants opportunities to correct errors, challenge interpretations and assess results; however, member checks are not without drawbacks. This paper describes an innovative approach to conducting member checks. Six members…

  20. Lot Quality Assurance Sampling of Sputum Acid-Fast Bacillus Smears for Assessing Sputum Smear Microscopy Centers

    PubMed Central

    Selvakumar, N.; Murthy, B. N.; Prabhakaran, E.; Sivagamasundari, S.; Vasanthan, Samuel; Perumal, M.; Govindaraju, R.; Chauhan, L. S.; Wares, Fraser; Santha, T.; Narayanan, P. R.

    2005-01-01

    Assessment of 12 microscopy centers in a tuberculosis unit by blinded checking of eight sputum smears selected by using a lot quality assurance sampling (LQAS) method and by unblinded checking of all positive and five negative slides, among the slides examined in a month in a microscopy centre, revealed that the LQAS method can be implemented in the field to monitor the performance of acid-fast bacillus microscopy centers in national tuberculosis control programs. PMID:15695704

  1. 14 CFR 121.441 - Proficiency checks.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... certificate holder may use any person nor may any person serve as a required pilot flight crewmember unless that person has satisfactorily completed either a proficiency check, or an approved simulator course of... check or the simulator training. (2) For all other pilots— (i) Within the preceding 24 calendar months...

  2. 14 CFR 121.441 - Proficiency checks.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... certificate holder may use any person nor may any person serve as a required pilot flight crewmember unless that person has satisfactorily completed either a proficiency check, or an approved simulator course of... check or the simulator training. (2) For all other pilots— (i) Within the preceding 24 calendar months...

  3. Tractor Mechanic Check Sheets for Modules.

    ERIC Educational Resources Information Center

    Clemson Univ., SC. Vocational Education Media Center.

    Forms for student self-checks and the instructor's final checklist (student evaluation) are provided for use with thirty-three learning modules on maintaining and servicing fuel and electrical systems in tractor mechanics. The student self-check asks the students questions about their understanding of the modules' content. The instructor's…

  4. 18 CFR 12.40 - Quality control programs.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... PROJECT WORKS Other Responsibilities of Applicant or Licensee § 12.40 Quality control programs. (a) General rule. During any construction, repair, or modification of project works, including any corrective... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Quality control...

  5. 18 CFR 12.40 - Quality control programs.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... PROJECT WORKS Other Responsibilities of Applicant or Licensee § 12.40 Quality control programs. (a) General rule. During any construction, repair, or modification of project works, including any corrective... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Quality control...

  6. 18 CFR 12.40 - Quality control programs.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... PROJECT WORKS Other Responsibilities of Applicant or Licensee § 12.40 Quality control programs. (a) General rule. During any construction, repair, or modification of project works, including any corrective... 18 Conservation of Power and Water Resources 1 2012-04-01 2012-04-01 false Quality control...

  7. 40 CFR Appendix B to Part 75 - Quality Assurance and Quality Control Procedures

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Systems 1.2.1Calibration Error Test and Linearity Check Procedures Keep a written record of the procedures used for daily calibration error tests and linearity checks (e.g., how gases are to be injected..., and when calibration adjustments should be made). Identify any calibration error test and linearity...

  8. 40 CFR Appendix B to Part 75 - Quality Assurance and Quality Control Procedures

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Systems 1.2.1Calibration Error Test and Linearity Check Procedures Keep a written record of the procedures used for daily calibration error tests and linearity checks (e.g., how gases are to be injected..., and when calibration adjustments should be made). Identify any calibration error test and linearity...

  9. 46 CFR 164.019-13 - Production quality control requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Production quality control requirements. 164.019-13....019-13 Production quality control requirements. (a) General. Each component manufacturer shall establish procedures for maintaining quality control of the materials used in production, manufacturing...

  10. 46 CFR 164.019-13 - Production quality control requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 6 2012-10-01 2012-10-01 false Production quality control requirements. 164.019-13....019-13 Production quality control requirements. (a) General. Each component manufacturer shall establish procedures for maintaining quality control of the materials used in production, manufacturing...

  11. 46 CFR 164.019-13 - Production quality control requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Production quality control requirements. 164.019-13....019-13 Production quality control requirements. (a) General. Each component manufacturer shall establish procedures for maintaining quality control of the materials used in production, manufacturing...

  12. 46 CFR 164.019-13 - Production quality control requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 6 2014-10-01 2014-10-01 false Production quality control requirements. 164.019-13....019-13 Production quality control requirements. (a) General. Each component manufacturer shall establish procedures for maintaining quality control of the materials used in production, manufacturing...

  13. 46 CFR 164.019-13 - Production quality control requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 6 2013-10-01 2013-10-01 false Production quality control requirements. 164.019-13....019-13 Production quality control requirements. (a) General. Each component manufacturer shall establish procedures for maintaining quality control of the materials used in production, manufacturing...

  14. The Effect of the MassHealth Hospital Pay-for-Performance Program on Quality

    PubMed Central

    Ryan, Andrew M; Blustein, Jan

    2011-01-01

    Objective To test the effect of Massachusetts Medicaid's (MassHealth) hospital-based pay-for-performance (P4P) program, implemented in 2008, on quality of care for pneumonia and surgical infection prevention (SIP). Data Hospital Compare process of care quality data from 2004 to 2009 for acute care hospitals in Massachusetts (N = 62) and other states (N = 3,676) and American Hospital Association data on hospital characteristics from 2005. Study Design Panel data models with hospital fixed effects and hospital-specific trends are estimated to test the effect of P4P on composite quality for pneumonia and SIP. This base model is extended to control for the completeness of measure reporting. Further sensitivity checks include estimation with propensity-score matched control hospitals, excluding hospitals in other P4P programs, varying the time period during which the program was assumed to have an effect, and testing the program effect across hospital characteristics. Principal Findings Estimates from our preferred specification, including hospital fixed effects, trends, and the control for measure completeness, indicate small and nonsignificant program effects for pneumonia (−0.67 percentage points, p>.10) and SIP (−0.12 percentage points, p>.10). Sensitivity checks indicate a similar pattern of findings across specifications. Conclusions Despite offering substantial financial incentives, the MassHealth P4P program did not improve quality in the first years of implementation. PMID:21210796

  15. Testing Intelligently Includes Double-Checking Wechsler IQ Scores

    ERIC Educational Resources Information Center

    Kuentzel, Jeffrey G.; Hetterscheidt, Lesley A.; Barnett, Douglas

    2011-01-01

    The rigors of standardized testing make for numerous opportunities for examiner error, including simple computational mistakes in scoring. Although experts recommend that test scoring be double-checked, the extent to which independent double-checking would reduce scoring errors is not known. A double-checking procedure was established at a…

  16. 40 CFR 86.321-79 - NDIR water rejection ratio check.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 19 2013-07-01 2013-07-01 false NDIR water rejection ratio check. 86.321-79 Section 86.321-79 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for New Gasoline-Fueled and...

  17. Quality by control: Towards model predictive control of mammalian cell culture bioprocesses.

    PubMed

    Sommeregger, Wolfgang; Sissolak, Bernhard; Kandra, Kulwant; von Stosch, Moritz; Mayer, Martin; Striedner, Gerald

    2017-07-01

    The industrial production of complex biopharmaceuticals using recombinant mammalian cell lines is still mainly built on a quality by testing approach, which is represented by fixed process conditions and extensive testing of the end-product. In 2004 the FDA launched the process analytical technology initiative, aiming to guide the industry towards advanced process monitoring and better understanding of how critical process parameters affect the critical quality attributes. Implementation of process analytical technology into the bio-production process enables moving from the quality by testing to a more flexible quality by design approach. The application of advanced sensor systems in combination with mathematical modelling techniques offers enhanced process understanding, allows on-line prediction of critical quality attributes and subsequently real-time product quality control. In this review opportunities and unsolved issues on the road to a successful quality by design and dynamic control implementation are discussed. A major focus is directed on the preconditions for the application of model predictive control for mammalian cell culture bioprocesses. Design of experiments providing information about the process dynamics upon parameter change, dynamic process models, on-line process state predictions and powerful software environments seem to be a prerequisite for quality by control realization. © 2017 The Authors. Biotechnology Journal published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Analytical approaches to quality assurance and quality control in rangeland monitoring data

    USDA-ARS?s Scientific Manuscript database

    Producing quality data to support land management decisions is the goal of every rangeland monitoring program. However, the results of quality assurance (QA) and quality control (QC) efforts to improve data quality are rarely reported. The purpose of QA and QC is to prevent and describe non-sampling...

  19. 7 CFR 1421.11 - Spot checks.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false Spot checks. 1421.11 Section 1421.11 Agriculture... ASSISTANCE LOANS AND LOAN DEFICIENCY PAYMENTS FOR 2008 THROUGH 2012 General § 1421.11 Spot checks. (a) CCC... CCC access to the farm and storage facility as necessary to conduct collateral inspections, or “spot...

  20. Professional Development for Water Quality Control Personnel.

    ERIC Educational Resources Information Center

    Shepard, Clinton Lewis

    This study investigated the availability of professional development opportunities for water quality control personnel in the midwest. The major objective of the study was to establish a listing of educational opportunities for the professional development of water quality control personnel and to compare these with the opportunities technicians…

  1. 31 CFR 240.16 - Checks issued to minor payees.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 31 Money and Finance:Treasury 2 2011-07-01 2011-07-01 false Checks issued to minor payees. 240.16... ON THE UNITED STATES TREASURY Indorsement of Checks § 240.16 Checks issued to minor payees. (a) Checks in payment of principal and/or interest on U.S. securities that are issued to minors may be...

  2. 31 CFR 240.16 - Checks issued to minor payees.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Checks issued to minor payees. 240.16... ON THE UNITED STATES TREASURY Indorsement of Checks § 240.16 Checks issued to minor payees. (a) Checks in payment of principal and/or interest on U.S. securities that are issued to minors may be...

  3. Using a Changing-Criterion Design to Evaluate the Effects of Check-In/Check-Out with Goal Modification

    ERIC Educational Resources Information Center

    McDaniel, Sara C.; Bruhn, Allison L.

    2016-01-01

    Check-in/check-out (CICO) is a Tier 2 behavioral intervention that has demonstrated effectiveness for students with challenging behavior in a variety of educational settings. Existing research has focused primarily on testing the intervention's effectiveness and the role of behavioral function in moderating response to intervention. Only a handful…

  4. Ride quality sensitivity to SAS control law and to handling quality variations

    NASA Technical Reports Server (NTRS)

    Roberts, P. A.; Schmidt, D. K.; Swaim, R. L.

    1976-01-01

    The RQ trends which large flexible aircraft exhibit under various parameterizations of control laws and handling qualities are discussed. A summary of the assumptions and solution technique, a control law parameterization review, a discussion of ride sensitivity to handling qualities, and the RQ effects generated by implementing relaxed static stability configurations are included.

  5. 14 CFR 21.147 - Changes in quality control system.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Changes in quality control system. 21.147 Section 21.147 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... quality control system. After the issue of a production certificate, each change to the quality control...

  6. 14 CFR 21.147 - Changes in quality control system.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Changes in quality control system. 21.147 Section 21.147 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... quality control system. After the issue of a production certificate, each change to the quality control...

  7. Checking for Ketones

    MedlinePlus

    ... doctor about them as well as record-keeping methods he or she recommends. Most include either packages of strips or foil-wrapped strips (which store longer). Urine tests are simple, but to get good results you have to follow directions carefully. Check ...

  8. Check & Connect: A Comprehensive Student Engagement Intervention Manual

    ERIC Educational Resources Information Center

    Christenson, Sandra L.; Thurlow, Martha L.; Sinclair, Mary F.; Lehr, Camilla A.; Kaibel, Colleen M.; Reschly, Amy L.; Mavis, Ann; Pohl, Angie

    2008-01-01

    Check & Connect was created in a five year period from 1990 to 1995. The original manual, entitled "Keeping Kids in School: Using Check & Connect for Dropout Prevention" and written by David Evelo, Mary Sinclair, Christine Hurley, Sandra Christenson, and Martha Thurlow, was published in 1996 (ED398701). This newly revised Check & Connect manual…

  9. 21 CFR 111.117 - What quality control operations are required for equipment, instruments, and controls?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What quality control operations are required for equipment, instruments, and controls? 111.117 Section 111.117 Food and Drugs FOOD AND DRUG ADMINISTRATION... and Process Control System: Requirements for Quality Control § 111.117 What quality control operations...

  10. New Applications of the Human Whole Blood Pyrogen Assay (PyroCheck).

    PubMed

    Fennrich; Wendel; Hartung

    1999-01-01

    The absence of pyrogens in injectable drugs is an indispensable safety control because contaminants causing fever pose a life-threatening risk to the patient resulting in the worst case in death by shock. When fever- inducing agents, i.e.pyrogens, come into contact with the immunocompetent cells in blood, these cells release mediators which transmit the fever signal to the thermoregulatory centre of the brain. The Phamocopoeia lists currently two test systems for pyrogenicity: 1. The in vivo rabbit pyrogen test which measures the fever reaction following injection of the sample to the animals. 2. The in vitro Limulus Amebocyte Lysate assay (LAL) which measures the coagulation in a lysate prepared from the blood of the horseshoe crab specifically initiated by endotoxins, i.e. cell wall components from Gram-negative bacteria. The new test presented here (PyroCheck) exploits the reaction of monocytes/macrophages for the detection of pyrogens: human whole blood taken from healthy volunteers is incubated in the presence of the test sample in any form, be it a solution, a powder or even solid material. Pyrogenic contaminations initiate the release of the "endogenous pyrogen" Interleukin-1beta determined by ELISA after a fixed incubation time. The technology presently listed in the Pharmacopoeia is limited to parenteralia (rabbit test: biologicals and pharmaceuticals, LAL: predominantly pharmaceuticals). In the EU Medical Devices Directive from 1995 the rabbit pyrogen test for medical products is in some cases requested. (in some cases LAL of an eluate from the device). However, pyrogen-testing needs to cover also innovative high-tech products such as medical devices (implants, medical plastic materials, dialysis machines), cellular therapies and species-specific agents (e.g. recombinant proteins). Here we report that the human blood test PyroCheck is suitable for testing filters in air quality control as well as for assessing medical devices and biocompatibility

  11. Colorado Air Quality Control Regulations and Ambient Air Quality Standards.

    ERIC Educational Resources Information Center

    Colorado State Dept. of Health, Denver. Div. of Air Pollution Control.

    Regulations and standards relative to air quality control in Colorado are defined in this publication. Presented first are definitions of terms, a statement of intent, and general provisions applicable to all emission control regulations adopted by the Colorado Air Pollution Control Commission. Following this, three regulations are enumerated: (1)…

  12. 46 CFR 164.120-11 - Production quality control requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 6 2014-10-01 2014-10-01 false Production quality control requirements. 164.120-11... Rescue Boats § 164.120-11 Production quality control requirements. The resin manufacturer must institute a quality control procedure to ensure that all Coast Guard-accepted resin is produced to the same...

  13. 46 CFR 164.120-11 - Production quality control requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 6 2012-10-01 2012-10-01 false Production quality control requirements. 164.120-11... Rescue Boats § 164.120-11 Production quality control requirements. The resin manufacturer must institute a quality control procedure to ensure that all Coast Guard-accepted resin is produced to the same...

  14. 46 CFR 164.120-11 - Production quality control requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 6 2013-10-01 2013-10-01 false Production quality control requirements. 164.120-11... Rescue Boats § 164.120-11 Production quality control requirements. The resin manufacturer must institute a quality control procedure to ensure that all Coast Guard-accepted resin is produced to the same...

  15. The Effects of Check-In/Check-Out on Problem Behavior and Academic Engagement in Elementary School Students

    ERIC Educational Resources Information Center

    Miller, Leila M.; Dufrene, Brad A.; Sterling, Heather E.; Olmi, D. Joe; Bachmayer, Erica

    2015-01-01

    This study evaluated the effectiveness of Check-in/Check-out (CICO) for improving behavioral performance for three students referred for Tier 2 behavioral supports. An ABAB withdrawal design was used to evaluate CICO and results indicate that intervention was effective for reducing problem behavior as well as increasing academic engagement for all…

  16. UTP and Temporal Logic Model Checking

    NASA Astrophysics Data System (ADS)

    Anderson, Hugh; Ciobanu, Gabriel; Freitas, Leo

    In this paper we give an additional perspective to the formal verification of programs through temporal logic model checking, which uses Hoare and He Unifying Theories of Programming (UTP). Our perspective emphasizes the use of UTP designs, an alphabetised relational calculus expressed as a pre/post condition pair of relations, to verify state or temporal assertions about programs. The temporal model checking relation is derived from a satisfaction relation between the model and its properties. The contribution of this paper is that it shows a UTP perspective to temporal logic model checking. The approach includes the notion of efficiency found in traditional model checkers, which reduced a state explosion problem through the use of efficient data structures

  17. SeaWiFS Technical Report Series. Volume 38; SeaWiFS Calibration and Validation Quality Control Procedures

    NASA Technical Reports Server (NTRS)

    Hooker, Stanford B. (Editor); Firestone, Elaine R. (Editor); McClain, Charles R.; Darzi, Michael; Barnes, Robert A.; Eplee, Robert E.; Firestone, James K.; Patt, Frederick S.; Robinson, Wayne D.; Schieber, Brian D.; hide

    1996-01-01

    This document provides five brief reports that address several quality control procedures under the auspices of the Calibration and Validation Element (CVE) within the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Project. Chapter 1 describes analyses of the 32 sensor engineering telemetry streams. Anomalies in any of the values may impact sensor performance in direct or indirect ways. The analyses are primarily examinations of parameter time series combined with statistical methods such as auto- and cross-correlation functions. Chapter 2 describes how the various onboard (solar and lunar) and vicarious (in situ) calibration data will be analyzed to quantify sensor degradation, if present. The analyses also include methods for detecting the influence of charged particles on sensor performance such as might be expected in the South Atlantic Anomaly (SAA). Chapter 3 discusses the quality control of the ancillary environmental data that are routinely received from other agencies or projects which are used in the atmospheric correction algorithm (total ozone, surface wind velocity, and surface pressure; surface relative humidity is also obtained, but is not used in the initial operational algorithm). Chapter 4 explains the procedures for screening level-, level-2, and level-3 products. These quality control operations incorporate both automated and interactive procedures which check for file format errors (all levels), navigation offsets (level-1), mask and flag performance (level-2), and product anomalies (all levels). Finally, Chapter 5 discusses the match-up data set development for comparing SeaWiFS level-2 derived products with in situ observations, as well as the subsequent outlier analyses that will be used for evaluating error sources.

  18. Coverage Metrics for Model Checking

    NASA Technical Reports Server (NTRS)

    Penix, John; Visser, Willem; Norvig, Peter (Technical Monitor)

    2001-01-01

    When using model checking to verify programs in practice, it is not usually possible to achieve complete coverage of the system. In this position paper we describe ongoing research within the Automated Software Engineering group at NASA Ames on the use of test coverage metrics to measure partial coverage and provide heuristic guidance for program model checking. We are specifically interested in applying and developing coverage metrics for concurrent programs that might be used to support certification of next generation avionics software.

  19. CMM Interim Check Design of Experiments (U)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Montano, Joshua Daniel

    2015-07-29

    Coordinate Measuring Machines (CMM) are widely used in industry, throughout the Nuclear Weapons Complex and at Los Alamos National Laboratory (LANL) to verify part conformance to design definition. Calibration cycles for CMMs at LANL are predominantly one year in length and include a weekly interim check to reduce risk. The CMM interim check makes use of Renishaw’s Machine Checking Gauge which is an off-the-shelf product simulates a large sphere within a CMM’s measurement volume and allows for error estimation. As verification on the interim check process a design of experiments investigation was proposed to test a couple of key factorsmore » (location and inspector). The results from the two-factor factorial experiment proved that location influenced results more than the inspector or interaction.« less

  20. First experiences with the LHC BLM sanity checks

    NASA Astrophysics Data System (ADS)

    Emery, J.; Dehning, B.; Effinger, E.; Nordt, A.; Sapinski, M. G.; Zamantzas, C.

    2010-12-01

    The reliability concerns have driven the design of the Large Hardron Collider (LHC) Beam Loss Monitoring (BLM) system from the early stage of the studies up to the present commissioning and the latest development of diagnostic tools. To protect the system against non-conformities, new ways of automatic checking have been developed and implemented. These checks are regularly and systematically executed by the LHC operation team to ensure that the system status is after each test "as good as new". The sanity checks are part of this strategy. They are testing the electrical part of the detectors (ionisation chamber or secondary emission detector), their cable connections to the front-end electronics, further connections to the back-end electronics and their ability to request a beam abort. During the installation and in the early commissioning phase, these checks have shown their ability to find also non-conformities caused by unexpected failure event scenarios. In every day operation, a non-conformity discovered by this check inhibits any further injections into the LHC until the check confirms the absence of non-conformities.

  1. Plan-Do-Check-Act and the Management of Institutional Research. AIR 1992 Annual Forum Paper.

    ERIC Educational Resources Information Center

    McLaughlin, Gerald W.; Snyder, Julie K.

    This paper describes the application of a Total Quality Management strategy called Plan-Do-Check-Act (PDCA) to the projects and activities of an institutional research office at the Virginia Polytechnic Institute and State University. PDCA is a cycle designed to facilitate incremental continual improvement through change. The specific steps are…

  2. Quality Control Technician Curriculum. An Elusive Butterfly.

    ERIC Educational Resources Information Center

    Holler, Michael

    Defining and developing a quality control technician curriculum for an associate degree program is a difficult and puzzling job. There are as many definitions of quality control and curriculum ideas as there are educators asked. However, one could start by dividing the field into its major areas--heavy manufacturing, maintenance, research, and…

  3. Ensuring the Quality of Data Packages in the LTER Network Provenance Aware Synthesis Tracking Architecture Data Management System and Archive

    NASA Astrophysics Data System (ADS)

    Servilla, M. S.; O'Brien, M.; Costa, D.

    2013-12-01

    Considerable ecological research performed today occurs through the analysis of data downloaded from various repositories and archives, often resulting in derived or synthetic products generated by automated workflows. These data are only meaningful for research if they are well documented by metadata, lest semantic or data type errors may occur in interpretation or processing. The Long Term Ecological Research (LTER) Network now screens all data packages entering its long-term archive to ensure that each package contains metadata that is complete, of high quality, and accurately describes the structure of its associated data entity and the data are structurally congruent to the metadata. Screening occurs prior to the upload of a data package into the Provenance Aware Synthesis Tracking Architecture (PASTA) data management system through a series of quality checks, thus preventing ambiguously or incorrectly documented data packages from entering the system. The quality checks within PASTA are designed to work specifically with the Ecological Metadata Language (EML), the metadata standard adopted by the LTER Network to describe data generated by their 26 research sites. Each quality check is codified in Java as part of the ecological community-supported Data Manager Library, which is a resource of the EML specification and used as a component of the PASTA software stack. Quality checks test for metadata quality, data integrity, or metadata-data congruence. Quality checks are further classified as either conditional or informational. Conditional checks issue a 'valid', 'warning' or 'error' response. Only an 'error' response blocks the data package from upload into PASTA. Informational checks only provide descriptive content pertaining to a particular facet of the data package. Quality checks are designed by a group of LTER information managers and reviewed by the LTER community before deploying into PASTA. A total of 32 quality checks have been deployed to date

  4. A multiple objective optimization approach to quality control

    NASA Technical Reports Server (NTRS)

    Seaman, Christopher Michael

    1991-01-01

    The use of product quality as the performance criteria for manufacturing system control is explored. The goal in manufacturing, for economic reasons, is to optimize product quality. The problem is that since quality is a rather nebulous product characteristic, there is seldom an analytic function that can be used as a measure. Therefore standard control approaches, such as optimal control, cannot readily be applied. A second problem with optimizing product quality is that it is typically measured along many dimensions: there are many apsects of quality which must be optimized simultaneously. Very often these different aspects are incommensurate and competing. The concept of optimality must now include accepting tradeoffs among the different quality characteristics. These problems are addressed using multiple objective optimization. It is shown that the quality control problem can be defined as a multiple objective optimization problem. A controller structure is defined using this as the basis. Then, an algorithm is presented which can be used by an operator to interactively find the best operating point. Essentially, the algorithm uses process data to provide the operator with two pieces of information: (1) if it is possible to simultaneously improve all quality criteria, then determine what changes to the process input or controller parameters should be made to do this; and (2) if it is not possible to improve all criteria, and the current operating point is not a desirable one, select a criteria in which a tradeoff should be made, and make input changes to improve all other criteria. The process is not operating at an optimal point in any sense if no tradeoff has to be made to move to a new operating point. This algorithm ensures that operating points are optimal in some sense and provides the operator with information about tradeoffs when seeking the best operating point. The multiobjective algorithm was implemented in two different injection molding scenarios

  5. 7 CFR 58.523 - Laboratory and quality control tests.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  6. 7 CFR 58.523 - Laboratory and quality control tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  7. 7 CFR 58.523 - Laboratory and quality control tests.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  8. 7 CFR 58.523 - Laboratory and quality control tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  9. 7 CFR 58.523 - Laboratory and quality control tests.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 3 2012-01-01 2012-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  10. 21 CFR 640.56 - Quality control test for potency.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... quality control test for potency may be performed by a clinical laboratory which meets the standards of... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Quality control test for potency. 640.56 Section...) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Cryoprecipitate § 640.56 Quality control...

  11. Web quality control for lectures: Supercourse and Amazon.com.

    PubMed

    Linkov, Faina; LaPorte, Ronald; Lovalekar, Mita; Dodani, Sunita

    2005-12-01

    Peer review has been at the corner stone of quality control of the biomedical journals in the past 300 years. With the emergency of the Internet, new models of quality control and peer review are emerging. However, such models are poorly investigated. We would argue that the popular system of quality control used in Amazon.com offers a way to ensure continuous quality improvement in the area of research communications on the Internet. Such system is providing an interesting alternative to the traditional peer review approaches used in the biomedical journals and challenges the traditional paradigms of scientific publishing. This idea is being explored in the context of Supercourse, a library of 2,350 prevention lectures, shared for free by faculty members from over 150 countries. Supercourse is successfully utilizing quality control approaches that are similar to Amazon.com model. Clearly, the existing approaches and emerging alternatives for quality control in scientific communications needs to be assessed scientifically. Rapid explosion of internet technologies could be leveraged to produce better, more cost effective systems for quality control in the biomedical publications and across all sciences.

  12. 26 CFR 301.6657-1 - Bad checks.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... money order is less than $500, the penalty shall be $5 or the amount of the check or money order... notice and demand therefor. (b) Reasonable cause. If payment is refused upon presentment of any check or...

  13. 26 CFR 301.6657-1 - Bad checks.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... money order is less than $500, the penalty shall be $5 or the amount of the check or money order... notice and demand therefor. (b) Reasonable cause. If payment is refused upon presentment of any check or...

  14. Poster - Thurs Eve-43: Verification of dose calculation with tissue inhomogeneity using MapCHECK.

    PubMed

    Korol, R; Chen, J; Mosalaei, H; Karnas, S

    2008-07-01

    MapCHECK (Sun Nuclear, Melbourne, FL) with 445 diode detectors has been used widely for routine IMRT quality assurance (QA) 1 . However, routine IMRT QA has not included the verification of inhomogeneity effects. The objective of this study is to use MapCHECK and a phantom to verify dose calculation and IMRT delivery with tissue inhomogeneity. A phantom with tissue inhomogeneities was placed on top of MapCHECK to measure the planar dose for an anterior beam with photon energy 6 MV or 18 MV. The phantom was composed of a 3.5 cm thick block of lung equivalent material and solid water arranged side by side with a 0.5 cm slab of solid water on the top of the phantom. The phantom setup including MapCHECK was CT scanned and imported into Pinnacle 8.0d for dose calculation. Absolute dose distributions were compared with gamma criteria 3% for dose difference and 3 mm for distance-to-agreement. The results are in good agreement between the measured and calculated planar dose with 88% pass rate based on the gamma analysis. The major dose difference was at the lung-water interface. Further investigation will be performed on a custom designed inhomogeneity phantom with inserts of varying densities and effective depth to create various dose gradients at the interface for dose calculation and delivery verification. In conclusion, a phantom with tissue inhomogeneities can be used with MapCHECK for verification of dose calculation and delivery with tissue inhomogeneity. © 2008 American Association of Physicists in Medicine.

  15. 40 CFR 81.107 - Greenwood Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Regions § 81.107 Greenwood Intrastate Air Quality Control Region. The Greenwood Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Greenwood Intrastate Air Quality...

  16. 40 CFR 81.108 - Columbia Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Regions § 81.108 Columbia Intrastate Air Quality Control Region. The Columbia Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... 40 Protection of Environment 17 2011-07-01 2011-07-01 false Columbia Intrastate Air Quality...

  17. 40 CFR 81.108 - Columbia Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Regions § 81.108 Columbia Intrastate Air Quality Control Region. The Columbia Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Columbia Intrastate Air Quality...

  18. 40 CFR 81.111 - Georgetown Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Regions § 81.111 Georgetown Intrastate Air Quality Control Region. The Georgetown Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... 40 Protection of Environment 17 2011-07-01 2011-07-01 false Georgetown Intrastate Air Quality...

  19. 40 CFR 81.109 - Florence Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Regions § 81.109 Florence Intrastate Air Quality Control Region. The Florence Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Florence Intrastate Air Quality...

  20. 40 CFR 81.111 - Georgetown Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Regions § 81.111 Georgetown Intrastate Air Quality Control Region. The Georgetown Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Georgetown Intrastate Air Quality...