Code of Federal Regulations, 2010 CFR
2010-04-01
... laboratory operations associated with the production and process control system? 111.110 Section 111.110 Food... OPERATIONS FOR DIETARY SUPPLEMENTS Production and Process Control System: Requirements for Quality Control... production and process control system? Quality control operations for laboratory operations associated with...
21 CFR 111.135 - What quality control operations are required for product complaints?
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What quality control operations are required for... MANUFACTURING, PACKAGING, LABELING, OR HOLDING OPERATIONS FOR DIETARY SUPPLEMENTS Production and Process Control System: Requirements for Quality Control § 111.135 What quality control operations are required for...
21 CFR 111.65 - What are the requirements for quality control operations?
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What are the requirements for quality control... Process Control System § 111.65 What are the requirements for quality control operations? You must implement quality control operations in your manufacturing, packaging, labeling, and holding operations for...
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What quality control operations are required for equipment, instruments, and controls? 111.117 Section 111.117 Food and Drugs FOOD AND DRUG ADMINISTRATION... and Process Control System: Requirements for Quality Control § 111.117 What quality control operations...
7 CFR 58.149 - Alternate quality control programs for dairy products.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 3 2011-01-01 2011-01-01 false Alternate quality control programs for dairy products... and Grading Service 1 Operations and Operating Procedures § 58.149 Alternate quality control programs for dairy products. (a) When a plant has in operation an acceptable quality control program which is...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-03
..., LLC, Wafer Slicing and Quality Control Operations, Including On-Site Leased Workers From Brown and... Quality Control Operations, Salem, Oregon, including on-site leased workers from Brown and Dunton, Inc... and included workers who supplied quality control and support functions. The company reports that...
Code of Federal Regulations, 2012 CFR
2012-04-01
... the master manufacturing record, the batch production record, and manufacturing operations? 111.123... for Quality Control § 111.123 What quality control operations are required for the master... for the master manufacturing record, the batch production record, and manufacturing operations must...
Code of Federal Regulations, 2013 CFR
2013-04-01
... the master manufacturing record, the batch production record, and manufacturing operations? 111.123... for Quality Control § 111.123 What quality control operations are required for the master... for the master manufacturing record, the batch production record, and manufacturing operations must...
Code of Federal Regulations, 2011 CFR
2011-04-01
... the master manufacturing record, the batch production record, and manufacturing operations? 111.123... for Quality Control § 111.123 What quality control operations are required for the master... for the master manufacturing record, the batch production record, and manufacturing operations must...
Code of Federal Regulations, 2014 CFR
2014-04-01
... the master manufacturing record, the batch production record, and manufacturing operations? 111.123... for Quality Control § 111.123 What quality control operations are required for the master... for the master manufacturing record, the batch production record, and manufacturing operations must...
7 CFR 58.523 - Laboratory and quality control tests.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 3 2014-01-01 2014-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...
7 CFR 58.523 - Laboratory and quality control tests.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...
7 CFR 58.523 - Laboratory and quality control tests.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 3 2013-01-01 2013-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...
7 CFR 58.523 - Laboratory and quality control tests.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 3 2011-01-01 2011-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...
7 CFR 58.523 - Laboratory and quality control tests.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 3 2012-01-01 2012-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...
40 CFR 136.7 - Quality assurance and quality control.
Code of Federal Regulations, 2014 CFR
2014-07-01
... quality control elements, where applicable, into the laboratory's documented standard operating procedure... quality control elements must be clearly documented in the written standard operating procedure for each... Methods contains QA/QC procedures in the Part 1000 section of the Standard Methods Compendium. The...
40 CFR 136.7 - Quality assurance and quality control.
Code of Federal Regulations, 2013 CFR
2013-07-01
... quality control elements, where applicable, into the laboratory's documented standard operating procedure... quality control elements must be clearly documented in the written standard operating procedure for each... Methods contains QA/QC procedures in the Part 1000 section of the Standard Methods Compendium. The...
40 CFR 136.7 - Quality assurance and quality control.
Code of Federal Regulations, 2012 CFR
2012-07-01
... quality control elements, where applicable, into the laboratory's documented standard operating procedure... quality control elements must be clearly documented in the written standard operating procedure for each... Methods contains QA/QC procedures in the Part 1000 section of the Standard Methods Compendium. The...
Stanley, D.L.
1995-01-01
The U.S. Geological Survey operates the National Field Quality Assurance Program to provide quality- assurance reference samples to field personnel who make water-quality field measurements. The program monitors the accuracy and precision of pH, specific conductance, and alkalinity field measurements. This report documents the operational procedures and quality-control techniques used in operating the quality-assurance program.
7 CFR 58.929 - Frequency of sampling for quality control.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 3 2011-01-01 2011-01-01 false Frequency of sampling for quality control. 58.929... Service 1 Operations and Operating Procedures § 58.929 Frequency of sampling for quality control. (a... to control composition. On continuous production runs, enough samples shall be taken throughout the...
7 CFR 58.442 - Laboratory and quality control tests.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.442 Section... Service 1 Operations and Operating Procedures § 58.442 Laboratory and quality control tests. (a) Chemical... Methods or by other methods giving equivalent results. (b) Weight or volume control. Representative...
7 CFR 58.442 - Laboratory and quality control tests.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 3 2011-01-01 2011-01-01 false Laboratory and quality control tests. 58.442 Section... Service 1 Operations and Operating Procedures § 58.442 Laboratory and quality control tests. (a) Chemical... Methods or by other methods giving equivalent results. (b) Weight or volume control. Representative...
A multiple objective optimization approach to quality control
NASA Technical Reports Server (NTRS)
Seaman, Christopher Michael
1991-01-01
The use of product quality as the performance criteria for manufacturing system control is explored. The goal in manufacturing, for economic reasons, is to optimize product quality. The problem is that since quality is a rather nebulous product characteristic, there is seldom an analytic function that can be used as a measure. Therefore standard control approaches, such as optimal control, cannot readily be applied. A second problem with optimizing product quality is that it is typically measured along many dimensions: there are many apsects of quality which must be optimized simultaneously. Very often these different aspects are incommensurate and competing. The concept of optimality must now include accepting tradeoffs among the different quality characteristics. These problems are addressed using multiple objective optimization. It is shown that the quality control problem can be defined as a multiple objective optimization problem. A controller structure is defined using this as the basis. Then, an algorithm is presented which can be used by an operator to interactively find the best operating point. Essentially, the algorithm uses process data to provide the operator with two pieces of information: (1) if it is possible to simultaneously improve all quality criteria, then determine what changes to the process input or controller parameters should be made to do this; and (2) if it is not possible to improve all criteria, and the current operating point is not a desirable one, select a criteria in which a tradeoff should be made, and make input changes to improve all other criteria. The process is not operating at an optimal point in any sense if no tradeoff has to be made to move to a new operating point. This algorithm ensures that operating points are optimal in some sense and provides the operator with information about tradeoffs when seeking the best operating point. The multiobjective algorithm was implemented in two different injection molding scenarios: tuning of process controllers to meet specified performance objectives and tuning of process inputs to meet specified quality objectives. Five case studies are presented.
Code of Federal Regulations, 2013 CFR
2013-04-01
... components, packaging, and labels before use in the manufacture of a dietary supplement? 111.120 Section 111..., OR HOLDING OPERATIONS FOR DIETARY SUPPLEMENTS Production and Process Control System: Requirements for... labels before use in the manufacture of a dietary supplement? Quality control operations for components...
Code of Federal Regulations, 2014 CFR
2014-04-01
... components, packaging, and labels before use in the manufacture of a dietary supplement? 111.120 Section 111..., OR HOLDING OPERATIONS FOR DIETARY SUPPLEMENTS Production and Process Control System: Requirements for... labels before use in the manufacture of a dietary supplement? Quality control operations for components...
Code of Federal Regulations, 2012 CFR
2012-04-01
... components, packaging, and labels before use in the manufacture of a dietary supplement? 111.120 Section 111..., OR HOLDING OPERATIONS FOR DIETARY SUPPLEMENTS Production and Process Control System: Requirements for... labels before use in the manufacture of a dietary supplement? Quality control operations for components...
Code of Federal Regulations, 2011 CFR
2011-04-01
... components, packaging, and labels before use in the manufacture of a dietary supplement? 111.120 Section 111..., OR HOLDING OPERATIONS FOR DIETARY SUPPLEMENTS Production and Process Control System: Requirements for... labels before use in the manufacture of a dietary supplement? Quality control operations for components...
Code of Federal Regulations, 2010 CFR
2010-04-01
... components, packaging, and labels before use in the manufacture of a dietary supplement? 111.120 Section 111..., OR HOLDING OPERATIONS FOR DIETARY SUPPLEMENTS Production and Process Control System: Requirements for... labels before use in the manufacture of a dietary supplement? Quality control operations for components...
21 CFR 111.105 - What must quality control personnel do?
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 2 2011-04-01 2011-04-01 false What must quality control personnel do? 111.105... for Quality Control § 111.105 What must quality control personnel do? Quality control personnel must... manufacturing record. To do so, quality control personnel must perform operations that include: (a) Approving or...
21 CFR 111.105 - What must quality control personnel do?
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What must quality control personnel do? 111.105..., LABELING, OR HOLDING OPERATIONS FOR DIETARY SUPPLEMENTS Production and Process Control System: Requirements for Quality Control § 111.105 What must quality control personnel do? Quality control personnel must...
78 FR 37850 - Quality Assurance Program Requirements (Operations)
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-24
... NUCLEAR REGULATORY COMMISSION [NRC-2013-0021] Quality Assurance Program Requirements (Operations... Regulatory Commission (NRC) is issuing a revision to Regulatory Guide (RG) 1.33, ``Quality Assurance Program... managerial and administrative Quality Assurance (QA) controls for nuclear power plants during operations...
Quality of life 15 years after sex reassignment surgery for transsexualism.
Kuhn, Annette; Bodmer, Christine; Stadlmayr, Werner; Kuhn, Peter; Mueller, Michael D; Birkhäuser, Martin
2009-11-01
To evaluate quality of life and patients' satisfaction in transsexual patients (TS) after sex reassignment operation compared with healthy controls. A case-control study. A tertiary referral center. Patients after sex reassignment operation were compared with a similar group of healthy controls in respect to quality of life and general satisfaction. For quality of life we used the King's Health Questionnaire, which was distributed to the patients and to the control group. Visual analogue scale was used for the determination of satisfaction. Main outcome measures were quality of life and satisfaction. Fifty-five transsexuals participated in this study. Fifty-two were male-to-female and 3 female-to-male. Quality of life as determined by the King's Health Questionnaire was significantly lower in general health, personal, physical and role limitations. Patients' satisfaction was significantly lower compared with controls. Emotions, sleep, and incontinence impact as well as symptom severity is similar to controls. Overall satisfaction was statistically significant lower in TS compared with controls. Fifteen years after sex reassignment operation quality of life is lower in the domains general health, role limitation, physical limitation, and personal limitation.
21 CFR 111.130 - What quality control operations are required for returned dietary supplements?
Code of Federal Regulations, 2014 CFR
2014-04-01
... returned dietary supplements? 111.130 Section 111.130 Food and Drugs FOOD AND DRUG ADMINISTRATION... PRACTICE IN MANUFACTURING, PACKAGING, LABELING, OR HOLDING OPERATIONS FOR DIETARY SUPPLEMENTS Production... are required for returned dietary supplements? Quality control operations for returned dietary...
21 CFR 111.130 - What quality control operations are required for returned dietary supplements?
Code of Federal Regulations, 2013 CFR
2013-04-01
... returned dietary supplements? 111.130 Section 111.130 Food and Drugs FOOD AND DRUG ADMINISTRATION... PRACTICE IN MANUFACTURING, PACKAGING, LABELING, OR HOLDING OPERATIONS FOR DIETARY SUPPLEMENTS Production... are required for returned dietary supplements? Quality control operations for returned dietary...
21 CFR 111.130 - What quality control operations are required for returned dietary supplements?
Code of Federal Regulations, 2011 CFR
2011-04-01
... returned dietary supplements? 111.130 Section 111.130 Food and Drugs FOOD AND DRUG ADMINISTRATION... PRACTICE IN MANUFACTURING, PACKAGING, LABELING, OR HOLDING OPERATIONS FOR DIETARY SUPPLEMENTS Production... are required for returned dietary supplements? Quality control operations for returned dietary...
21 CFR 111.130 - What quality control operations are required for returned dietary supplements?
Code of Federal Regulations, 2012 CFR
2012-04-01
... returned dietary supplements? 111.130 Section 111.130 Food and Drugs FOOD AND DRUG ADMINISTRATION... PRACTICE IN MANUFACTURING, PACKAGING, LABELING, OR HOLDING OPERATIONS FOR DIETARY SUPPLEMENTS Production... are required for returned dietary supplements? Quality control operations for returned dietary...
21 CFR 111.130 - What quality control operations are required for returned dietary supplements?
Code of Federal Regulations, 2010 CFR
2010-04-01
... returned dietary supplements? 111.130 Section 111.130 Food and Drugs FOOD AND DRUG ADMINISTRATION... PRACTICE IN MANUFACTURING, PACKAGING, LABELING, OR HOLDING OPERATIONS FOR DIETARY SUPPLEMENTS Production... are required for returned dietary supplements? Quality control operations for returned dietary...
1988-05-01
compensatory operations as a dual-mods control -- a form where the control exerted is Initiated and largely accomplished by the precognitive action and then...function. Fig. 3.2 Compensatory control structure for 4-7 precognitive operation occur in a "dual- quality criteria one is referred to mode" control... precognitive action Tesil itatieet rpoas f and then completed with compensatory error- mil quent ei to eure a reduction operations (Ref. 11). certary eqe mso
21 CFR 111.127 - What quality control operations are required for packaging and labeling operations?
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What quality control operations are required for packaging and labeling operations? 111.127 Section 111.127 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION CURRENT GOOD MANUFACTURING...
40 CFR 75.21 - Quality assurance and quality control requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Quality assurance and quality control... PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Operation and Maintenance Requirements § 75.21 Quality assurance and quality control requirements. (a) Continuous emission monitoring systems. The owner or...
7 CFR 58.928 - Quality control tests.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 3 2011-01-01 2011-01-01 false Quality control tests. 58.928 Section 58.928... Procedures § 58.928 Quality control tests. All dairy products and other ingredients shall be subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be...
7 CFR 58.335 - Quality control tests.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 3 2011-01-01 2011-01-01 false Quality control tests. 58.335 Section 58.335... Procedures § 58.335 Quality control tests. All milk, cream and related products are subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be made on flow...
Quality Assurance of Chemical Measurements.
ERIC Educational Resources Information Center
Taylor, John K.
1981-01-01
Reviews aspects of quality control (methods to control errors) and quality assessment (verification that systems are operating within acceptable limits) including an analytical measurement system, quality control by inspection, control charts, systematic errors, and use of SRMs, materials for which properties are certified by the National Bureau…
Quality assurance: Importance of systems and standard operating procedures
Manghani, Kishu
2011-01-01
It is mandatory for sponsors of clinical trials and contract research organizations alike to establish, manage and monitor their quality control and quality assurance systems and their integral standard operating procedures and other quality documents to provide high-quality products and services to fully satisfy customer needs and expectations. Quality control and quality assurance systems together constitute the key quality systems. Quality control and quality assurance are parts of quality management. Quality control is focused on fulfilling quality requirements, whereas quality assurance is focused on providing confidence that quality requirements are fulfilled. The quality systems must be commensurate with the Company business objectives and business model. Top management commitment and its active involvement are critical in order to ensure at all times the adequacy, suitability, effectiveness and efficiency of the quality systems. Effective and efficient quality systems can promote timely registration of drugs by eliminating waste and the need for rework with overall financial and social benefits to the Company. PMID:21584180
Quality assurance: Importance of systems and standard operating procedures.
Manghani, Kishu
2011-01-01
It is mandatory for sponsors of clinical trials and contract research organizations alike to establish, manage and monitor their quality control and quality assurance systems and their integral standard operating procedures and other quality documents to provide high-quality products and services to fully satisfy customer needs and expectations. Quality control and quality assurance systems together constitute the key quality systems. Quality control and quality assurance are parts of quality management. Quality control is focused on fulfilling quality requirements, whereas quality assurance is focused on providing confidence that quality requirements are fulfilled. The quality systems must be commensurate with the Company business objectives and business model. Top management commitment and its active involvement are critical in order to ensure at all times the adequacy, suitability, effectiveness and efficiency of the quality systems. Effective and efficient quality systems can promote timely registration of drugs by eliminating waste and the need for rework with overall financial and social benefits to the Company.
14 CFR 145.211 - Quality control system.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Quality control system. 145.211 Section 145...) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Operating Rules § 145.211 Quality control system. (a) A certificated repair station must establish and maintain a quality control system acceptable to...
14 CFR 145.211 - Quality control system.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Quality control system. 145.211 Section 145...) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Operating Rules § 145.211 Quality control system. (a) A certificated repair station must establish and maintain a quality control system acceptable to...
7 CFR 58.141 - Alternate quality control program.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 3 2011-01-01 2011-01-01 false Alternate quality control program. 58.141 Section 58... Service 1 Quality Specifications for Raw Milk § 58.141 Alternate quality control program. When a plant has in operation an acceptable quality program, at the producer level, which is approved by the...
Zheng, Caixian; Zheng, Kun; Shen, Yunming; Wu, Yunyun
2016-01-01
The content related to the quality during life-cycle in operation of medical device includes daily use, repair volume, preventive maintenance, quality control and adverse event monitoring. In view of this, the article aims at discussion on the quality evaluation method of medical devices during their life cycle in operation based on the Analytic Hierarchy Process (AHP). The presented method is proved to be effective by evaluating patient monitors as example. The method presented in can promote and guide the device quality control work, and it can provide valuable inputs to decisions about purchase of new device.
Power-Quality Improvement in PFC Bridgeless SEPIC-Fed BLDC Motor Drive
NASA Astrophysics Data System (ADS)
Singh, Bhim; Bist, Vashist
2013-06-01
This article presents a design of a power factor correction (PFC)-based brushless DC (BLDC) motor drive. The speed control of BLDC motor is achieved by controlling the DC link voltage of the voltage source inverter (VSI) feeding BLDC motor using a single voltage sensor. A front-end bridgeless single-ended primary inductance converter (SEPIC) is used for DC link voltage control and PFC operation. A bridgeless SEPIC is designed to operate in discontinuous inductor current mode (DICM) thus utilizing a simple control scheme of voltage follower. An electronic commutation of BLDC motor is used for VSI to operate in a low-frequency operation for reduced switching losses in the VSI. Moreover, a bridgeless topology offers less conduction losses due to absence of diode bridge rectifier for further increasing the efficiency. The proposed BLDC motor drive is designed to operate over a wide range of speed control with an improved power-quality at the AC mains under the recommended international power-quality standards such as IEC 61000-3-2.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-24
... Energy and Non-Air Quality Environmental Impacts C. Comments on Factor Three--Existing Controls at FCPP D... compliance, (2) the energy and non-air quality environmental impacts of compliance, (3) any pollution control... installing and operating any of several equivalent controls on Units 1- 3, and through proper operation of...
[Coronary artery bypass surgery: methods of performance monitoring and quality control].
Albert, A; Sergeant, P; Ennker, J
2009-10-01
The strength of coronary bypass operations depends on the preservation of their benefits regarding freedom of symptoms, quality of life and survival, over decades. Significant variability of the results of an operative intervention according to the hospital or the operating surgeon is considered a weakness in the procedure. The external quality insurance tries to reach a transparent service providing market through hospital ranking comparability. Widely available information and competition will promote the improvement of the whole quality. The structured dialog acts as a control instrument for the BQS (Federal Quality Insurance). It is launched in case of deviations from the standard references or statistically significant differences between the results of the operations in any hospital and the average notational results. In comparison to the external control the hospital internal control has greater ability to reach a medically useful statement regarding the results of the treatment and to correct the mistakes in time. An online information portal based on a departmental databank (DataWarehouse, DataMart) is an attractive solution for the physician in order to get transparently and timely informed about the variability in the performance.The individual surgeon significantly influences the short- and long-term treatment results. Accordingly, selection, targeted training and performance measurements are necessary.Strict risk management and failure analysis of individual cases are included in the methods of internal quality control aiming to identify and correct the inadequacies in the system and the course of treatment. According to the international as well as our own experience, at least 30% of the mortalities after bypass operations are avoidable. A functioning quality control is especially important in minimally invasive interventions because they are often technically more demanding in comparison to the conventional procedures. In the field of OPCAB surgery, the special advantages of the procedure can be utilised to reach a nearly complete avoidance of postoperative stroke through combining the procedure with aorta no-touch technique. The long-term success of the bypass operation depends on the type of bypass material in additions to many other factors. Both internal mammary arteries are considered the most durable.Using an operation preparation check contributes to the operative success.
Control by quality: proposition of a typology.
Pujo, P; Pillet, M
The application of Quality tools and methods in industrial management has always had a fundamental impact on the control of production. It influences the behavior of the actors concerned, while introducing the necessary notions and formalizations, especially for production systems with little or no automation, which constitute a large part of the industrial activity. Several quality approaches are applied in the workshop and are implemented at the level of the control. In this paper, the authors present a typology of the various approaches that have successively influenced control, such as statistical process control, quality assurance, and continuous improvement. First the authors present a parallel between production control and quality organizational structure. They note the duality between control, which is aimed at increasing productivity, and quality, which aims to satisfy the needs of the customer. They also note the hierarchical organizational structure of these two systems of management with, at each level, the notion of a feedback loop. This notion is fundamental to any kind of decision making. The paper is organized around the operational, tactical, and strategic levels, by describing for each level the main methods and tools for control by quality. The overview of these tools and methods starts at the operational level, with the Statistical Process Control, the Taguchi technique, and the "six sigma" approach. On the tactical level, we find a quality system approach, with a documented description of the procedures introduced in the firm. The management system can refer here to Quality Assurance, Total Productive Maintenance, or Management by Total Quality. The formalization through procedures of the rules of decision governing the process control enhances the validity of these rules. This leads to the enhancement of their reliability and to their consolidation. All this counterbalances the human, intrinsically fluctuating, behavior of the control operators. Strategic control by quality is then detailed, and the two main approaches, the continuous improvement approach and the proactive improvement approach, are introduced. Finally, the authors observe that at each of the three levels, the continuous process improvement, which is a component of Total Quality, becomes an essential preoccupation for the control. Ultimately, the recursive utilization of the Deming cycle remains the best practice for the control by quality.
Producing Quality Water for Industrial Use.
ERIC Educational Resources Information Center
Schaezler, Donald J.
1978-01-01
This article discusses the quality of water demanded by industrial plants and the techniques which are currently employed to achieve them. Both quality and quantity requirements are considered including total plant operation, physical and chemical operating controls, and systems monitoring. (CS)
Clinical Outcomes of Reoperation for Failed Antireflux Operations.
Wilshire, Candice L; Louie, Brian E; Shultz, Dale; Jutric, Zeljka; Farivar, Alexander S; Aye, Ralph W
2016-04-01
Up to 18% of patients undergoing antireflux operations will require reoperation. Authors caution that with each additional reoperation, fewer patients achieve satisfaction. The quality of life in patients who underwent revision operations was compared with patients who underwent primary antireflux operations to determine the effectiveness of revision operations. We retrospectively reviewed patients who underwent revision after failed antireflux operations from 2004 to 2014. Patients were divided into two groups: first reoperation (Reop[1]) and more than one reoperation (Reop[>1]). For comparison, a control group of patients who underwent primary antireflux operations was included. Patients underwent quality of life assessment preoperatively and postoperatively. We identified 105 reoperative patients: 94 Reop(1), 11 Reop(>1), and 112 controls. The primary reason for failure was combined fundoplication herniation and slippage. Morbidity, mortality, and readmission rates were similar in all groups. Postoperative outcomes were improved in all groups but to a lesser degree in subsequent reoperations. Gastroesophageal Reflux Disease Health-Related Quality of Life: controls, 20.0 to 2.0; Reop(1), 26.5 to 4.0; and Reop(>1), 13.0 to 2.0. Quality of Life in Reflux and Dyspepsia: controls, 4.5 to 7.0; Reop(1), 3.7 to 6.7; and Reop(>1), 3.5 to 5.8. Dysphagia Severity Score: controls, 44.0 to 45.0; Reop(1), 36.0 to 45.0; and Reop(>1), 30.8 to 45.0. Patients undergoing revision antireflux operations have improved quality of life, relatively normal swallowing, and primary symptom resolution at a median of 20 months postoperatively. However, patients who undergo more than one reoperation have lower quality of life scores and less improvement in dysphagia, suggesting that other procedures such as Roux-en-Y or short colon interposition, should be considered after a failed initial reoperation. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
77 FR 73611 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-11
...: Negative Quality Control Review Schedule. OMB Control Number: 0584-0034. Summary of Collection: The legislative basis for the operation of the quality control system is provided by section 16 of the Food and Nutrition Act of 2008. State agencies are required to perform Quality Control (QC) reviews for the...
Statistical process control: separating signal from noise in emergency department operations.
Pimentel, Laura; Barrueto, Fermin
2015-05-01
Statistical process control (SPC) is a visually appealing and statistically rigorous methodology very suitable to the analysis of emergency department (ED) operations. We demonstrate that the control chart is the primary tool of SPC; it is constructed by plotting data measuring the key quality indicators of operational processes in rationally ordered subgroups such as units of time. Control limits are calculated using formulas reflecting the variation in the data points from one another and from the mean. SPC allows managers to determine whether operational processes are controlled and predictable. We review why the moving range chart is most appropriate for use in the complex ED milieu, how to apply SPC to ED operations, and how to determine when performance improvement is needed. SPC is an excellent tool for operational analysis and quality improvement for these reasons: 1) control charts make large data sets intuitively coherent by integrating statistical and visual descriptions; 2) SPC provides analysis of process stability and capability rather than simple comparison with a benchmark; 3) SPC allows distinction between special cause variation (signal), indicating an unstable process requiring action, and common cause variation (noise), reflecting a stable process; and 4) SPC keeps the focus of quality improvement on process rather than individual performance. Because data have no meaning apart from their context, and every process generates information that can be used to improve it, we contend that SPC should be seriously considered for driving quality improvement in emergency medicine. Copyright © 2015 Elsevier Inc. All rights reserved.
Image registration assessment in radiotherapy image guidance based on control chart monitoring.
Xia, Wenyao; Breen, Stephen L
2018-04-01
Image guidance with cone beam computed tomography in radiotherapy can guarantee the precision and accuracy of patient positioning prior to treatment delivery. During the image guidance process, operators need to take great effort to evaluate the image guidance quality before correcting a patient's position. This work proposes an image registration assessment method based on control chart monitoring to reduce the effort taken by the operator. According to the control chart plotted by daily registration scores of each patient, the proposed method can quickly detect both alignment errors and image quality inconsistency. Therefore, the proposed method can provide a clear guideline for the operators to identify unacceptable image quality and unacceptable image registration with minimal effort. Experimental results demonstrate that by using control charts from a clinical database of 10 patients undergoing prostate radiotherapy, the proposed method can quickly identify out-of-control signals and find special cause of out-of-control registration events.
Handling Qualities Implications for Crewed Spacecraft Operations
NASA Technical Reports Server (NTRS)
Bailey, Randall E.; Jackson, E. Bruce; Arthur, J. J.
2012-01-01
Abstract Handling qualities embody those qualities or characteristics of an aircraft that govern the ease and precision with which a pilot is able to perform the tasks required in support of an aircraft role. These same qualities are as critical, if not more so, in the operation of spacecraft. A research, development, test, and evaluation process was put into effect to identify, understand, and interpret the engineering and human factors principles which govern the pilot-vehicle dynamic system as they pertain to space exploration missions and tasks. Toward this objective, piloted simulations were conducted at the NASA Langley Research Center and Ames Research Center for earth-orbit proximity operations and docking and lunar landing. These works provide broad guidelines for the design of spacecraft to exhibit excellent handling characteristics. In particular, this work demonstrates how handling qualities include much more than just stability and control characteristics of a spacecraft or aircraft. Handling qualities are affected by all aspects of the pilot-vehicle dynamic system, including the motion, visual and aural cues of the vehicle response as the pilot performs the required operation or task. A holistic approach to spacecraft design, including the use of manual control, automatic control, and pilot intervention/supervision is described. The handling qualities implications of design decisions are demonstrated using these pilot-in-the-loop evaluations of docking operations and lunar landings.
10 CFR 75.23 - Operating records.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Accounting and Control for Facilities § 75.23 Operating records. The operating records required by § 75.21... to control the quality of measurements, and the derived estimates of random and systematic error; (c...
ERIC Educational Resources Information Center
New York State Dept. of Environmental Conservation, Albany.
This report contains information to assist organizations and personnel responsible for the quality and quantity of operators available for water quality control efforts. The text discusses in detail the current developments in operator instructional programs. Each of the seven sections of this report deals with a specific aspect of manpower…
Assessment of flying-quality criteria for air-breathing aerospacecraft
NASA Technical Reports Server (NTRS)
Mcruer, Duane T.; Myers, Thomas T.; Hoh, Roger H.; Ashkenas, Irving L.; Johnston, Donald E.
1992-01-01
A study of flying quality requirements for air breathing aerospacecraft gives special emphasis to the unusual operational requirements and characteristics of these aircraft, including operation at hypersonic speed. The report considers distinguishing characteristics of these vehicles, including dynamic deficiencies and their implications for control. Particular emphasis is given to the interaction of the airframe and propulsion system, and the requirements for dynamic systems integration. Past operational missions are reviewed to define tasks and maneuvers to be considered for this class of aircraft. Areas of special concern with respect to vehicle dynamics and control are identified. Experience with the space shuttle orbiter is reviewed with respect to flight control system mechanization and flight experience in approach and landing flying qualities for the National Aerospace Plane (NASP).
Code of Federal Regulations, 2010 CFR
2010-10-01
... SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) QUALITY IMPROVEMENT ORGANIZATIONS UTILIZATION AND QUALITY CONTROL REVIEW Review Responsibilities of Utilization and Quality Control Quality... information on charges) that are pertinent to health care services furnished to Medicare beneficiaries and are...
Commercial jet fuel quality control
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strauss, K.H.
1995-05-01
The paper discusses the purpose of jet fuel quality control between the refinery and the aircraft. It describes fixed equipment, including various types of filters, and the usefulness and limitations of this equipment. Test equipment is reviewed as are various surveillance procedures. These include the Air Transport Association specification ATA 103, the FAA Advisory Circular 150/5230-4, the International Air Transport Association Guidance Material for Fuel Quality Control and Fuelling Service and the Guidelines for Quality Control at Jointly Operated Fuel Systems. Some past and current quality control problems are briefly mentioned.
Performance evaluation of traffic sensing and control devices : [technical summary].
DOT National Transportation Integrated Search
2011-01-01
High quality sensing and control systems are essential for providing efficient signalized arterial operations. INDOT operates over 2600 traffic signal controllers, approximately 2000 of which use some form of vehicle detection. The private sector con...
Quality-of-life in patients with Dercum's disease--before and after liposuction.
Hansson, Emma; Manjer, Jonas; Svensson, Henry; Brorson, Håkan
2012-09-01
Dercum's disease is characterised by obesity, pronounced pain in the adipose tissue, and a number of associated symptoms. Liposuction has been suggested as a treatment. However, the effect on quality-of-life after liposuction in Dercum's disease has never been investigated. The objective of this study was to examine the quality-of-life in Dercum's disease before and after liposuction. A total of 114 women fulfilling the clinical criteria of Dercum's disease were included. Of the 114 women, 53 were operated on with liposuction and 61 were Dercum controls. In addition, 41 obese healthy women operated on with abdominoplasty were recruited as controls. Health-related quality-of-life (HRQoL) was measured with the Nottingham Health Profile (NHP) and the Psychological General Well-Being index (PGWB). The Dercum group had lower HRQoL than the abdominoplasty controls. After liposuction, a slight improvement could be seen in HRQoL in the operated patients compared with preoperatively, but it did not become as high as in the abdominoplasty patients. In conclusion, the findings could suggest that liposuction improves the quality-of-life slightly in Dercum's disease. Nonetheless, the causality is unclear and the improvement is not big enough to warrant operation.
Expert database system for quality control
NASA Astrophysics Data System (ADS)
Wang, Anne J.; Li, Zhi-Cheng
1993-09-01
There are more competitors today. Markets are not homogeneous they are fragmented into increasingly focused niches requiring greater flexibility in the product mix shorter manufacturing production runs and above allhigher quality. In this paper the author identified a real-time expert system as a way to improve plantwide quality management. The quality control expert database system (QCEDS) by integrating knowledge of experts in operations quality management and computer systems use all information relevant to quality managementfacts as well as rulesto determine if a product meets quality standards. Keywords: expert system quality control data base
Argo workstation: a key component of operational oceanography
NASA Astrophysics Data System (ADS)
Dong, Mingmei; Xu, Shanshan; Miao, Qingsheng; Yue, Xinyang; Lu, Jiawei; Yang, Yang
2018-02-01
Operational oceanography requires the quantity, quality, and availability of data set and the timeliness and effectiveness of data products. Without steady and strong operational system supporting, operational oceanography will never be proceeded far. In this paper we describe an integrated platform named Argo Workstation. It operates as a data processing and management system, capable of data collection, automatic data quality control, visualized data check, statistical data search and data service. After it is set up, Argo workstation provides global high quality Argo data to users every day timely and effectively. It has not only played a key role in operational oceanography but also set up an example for operational system.
Lierman, Sylvie; De Sutter, Petra; Dhont, Marc; Van der Elst, Josiane
2007-10-01
To submit different glove brands to double-quality control tests using mouse embryo assay (MEA) and the human sperm motility assay (HuSMA). Operator protection against infectious body fluid contamination is a safety issue in assisted reproductive technology (ART). When using gloves in the ART laboratory, toxic substances can be transmitted to culture media, even during brief contact. Quality control study of gloves in ART. University hospital-based infertility center. Seven- to 8-week-old female B6D2F1 hybrid mice. We tested two surgical, two cleanroom, and six examination glove brands. Only gloves brands that passed both HuSMA and MEA were submitted to further QC using zona-free and/or cryopreserved MEA. Sperm motility index, two-cell and blastocyst development, blastocyst total cell number. Quality control by MEA and HuSMA identified two glove brands to be nontoxic. Our study shows that gloves used in ART can be toxic and should be tested as part of an ongoing quality control program.
This protocol describes how quality control samples should be handled in the field, and was designed as a quick reference source for the field staff. The protocol describes quality control samples for air-VOCs, air-particles, water samples, house dust, soil, urine, blood, hair, a...
Effects of Meteorological Data Quality on Snowpack Modeling
NASA Astrophysics Data System (ADS)
Havens, S.; Marks, D. G.; Robertson, M.; Hedrick, A. R.; Johnson, M.
2017-12-01
Detailed quality control of meteorological inputs is the most time-intensive component of running the distributed, physically-based iSnobal snow model, and the effect of data quality of the inputs on the model is unknown. The iSnobal model has been run operationally since WY2013, and is currently run in several basins in Idaho and California. The largest amount of user input during modeling is for the quality control of precipitation, temperature, relative humidity, solar radiation, wind speed and wind direction inputs. Precipitation inputs require detailed user input and are crucial to correctly model the snowpack mass. This research applies a range of quality control methods to meteorological input, from raw input with minimal cleaning, to complete user-applied quality control. The meteorological input cleaning generally falls into two categories. The first is global minimum/maximum and missing value correction that could be corrected and/or interpolated with automated processing. The second category is quality control for inputs that are not globally erroneous, yet are still unreasonable and generally indicate malfunctioning measurement equipment, such as temperature or relative humidity that remains constant, or does not correlate with daily trends observed at nearby stations. This research will determine how sensitive model outputs are to different levels of quality control and guide future operational applications.
Nájera, S; Gil-Martínez, M; Zambrano, J A
2015-01-01
The aim of this paper is to establish and quantify different operational goals and control strategies in autothermal thermophilic aerobic digestion (ATAD). This technology appears as an alternative to conventional sludge digestion systems. During the batch-mode reaction, high temperatures promote sludge stabilization and pasteurization. The digester temperature is usually the only online, robust, measurable variable. The average temperature can be regulated by manipulating both the air injection and the sludge retention time. An improved performance of diverse biochemical variables can be achieved through proper manipulation of these inputs. However, a better quality of treated sludge usually implies major operating costs or a lower production rate. Thus, quality, production and cost indices are defined to quantify the outcomes of the treatment. Based on these, tradeoff control strategies are proposed and illustrated through some examples. This paper's results are relevant to guide plant operators, to design automatic control systems and to compare or evaluate the control performance on ATAD systems.
Improving and monitoring air quality.
DuPont, André
2018-05-01
Since the authorization of the Clean Air Act Amendments of 1990, the air quality in the USA has significantly improved because of strong public support. The lessons learned over the last 25 years are being shared with the policy analysts, technical professionals, and scientist who endeavor to improve air quality in their communities. This paper will review how the USA has achieved the "high" standard of air quality that was envisioned in the early 1990s. This document will describe SO 2 gas emission reduction technology and highlight operation of emission monitoring technology. This paper describes the basic process operation of an air pollution control scrubber. A technical review of measures required to operate and maintain a large-scale pollution control system will be described. Also, the author explains how quality assurance procedures in performance of continuous emission monitoring plays a significant role in reducing air pollution.
Performance evaluation of traffic sensing and control devices.
DOT National Transportation Integrated Search
2011-01-01
High quality vehicle detection is essential to properly operate actuated phases at traffic signals and to facilitate effective : management of technician and engineering resources. INDOT operates over 2600 traffic signal controllers, approximately 20...
This SOP describes the method for conducting internal field audits and quality control procedures. Internal field audits will be conducted to ensure the collection of high quality data. Internal field audits will be conducted by Field Auditors (the Field QA Officer and the Field...
Harding, Keith; Benson, Erica E
2015-01-01
Standard operating procedures are a systematic way of making sure that biopreservation processes, tasks, protocols, and operations are correctly and consistently performed. They are the basic documents of biorepository quality management systems and are used in quality assurance, control, and improvement. Methodologies for constructing workflows and writing standard operating procedures and work instructions are described using a plant cryopreservation protocol as an example. This chapter is pertinent to other biopreservation sectors because how methods are written, interpreted, and implemented can affect the quality of storage outcomes.
An In-Process Surface Roughness Recognition System in End Milling Operations
ERIC Educational Resources Information Center
Yang, Lieh-Dai; Chen, Joseph C.
2004-01-01
To develop an in-process quality control system, a sensor technique and a decision-making algorithm need to be applied during machining operations. Several sensor techniques have been used in the in-process prediction of quality characteristics in machining operations. For example, an accelerometer sensor can be used to monitor the vibration of…
Lin, Yanjuan; Xu, Le; Huang, Xizhen; Jiang, Fei; Lin, Fen; Ye, Qingyang; Lin, Jianling
2016-01-01
To investigate the effects of non-drug interventions on the sleep quality of patients after mechanical cardiac valve implantation. In this prospective, randomized, controlled trial, 64 patients scheduled for mechanical mitral valve replacement were recruited. Patients underwent cognitive behavioral therapy and wore noise cancelling earplugs and eye mask. Sleep quality was evaluated on the 4th after admission and the 5th days after operation. The primary outcome was the total sleep quality score differences between the 4th day after admission and the 5th day after operation. All patients had been suffering from poor sleep quality for a month before admission. There was no difference between both groups on the 4th day after admission. Overall sleep quality in the intervention group was better than in the control group on the 5th day after operation. The subjective sleep quality of the patients in each group was significantly lower on the 5th day after the operation than on the 4th day after admission (P <0.05). Non-drug intervention could improve the sleep quality of patients after mechanical cardiac valve implantation and help the postoperative recovery of the patients. ( ChiCTR-TRC-14004405, 21 March 2014.).
This standard operating procedure describes the method used for the determination of target analytes in sample extracts and related quality assurance/quality control sample extracts generated in the CTEPP study.
Human Connectome Project Informatics: quality control, database services, and data visualization
Marcus, Daniel S.; Harms, Michael P.; Snyder, Abraham Z.; Jenkinson, Mark; Wilson, J Anthony; Glasser, Matthew F.; Barch, Deanna M.; Archie, Kevin A.; Burgess, Gregory C.; Ramaratnam, Mohana; Hodge, Michael; Horton, William; Herrick, Rick; Olsen, Timothy; McKay, Michael; House, Matthew; Hileman, Michael; Reid, Erin; Harwell, John; Coalson, Timothy; Schindler, Jon; Elam, Jennifer S.; Curtiss, Sandra W.; Van Essen, David C.
2013-01-01
The Human Connectome Project (HCP) has developed protocols, standard operating and quality control procedures, and a suite of informatics tools to enable high throughput data collection, data sharing, automated data processing and analysis, and data mining and visualization. Quality control procedures include methods to maintain data collection consistency over time, to measure head motion, and to establish quantitative modality-specific overall quality assessments. Database services developed as customizations of the XNAT imaging informatics platform support both internal daily operations and open access data sharing. The Connectome Workbench visualization environment enables user interaction with HCP data and is increasingly integrated with the HCP's database services. Here we describe the current state of these procedures and tools and their application in the ongoing HCP study. PMID:23707591
21 CFR 111.103 - What are the requirements under this subpart F for written procedures?
Code of Federal Regulations, 2010 CFR
2010-04-01
... MANUFACTURING, PACKAGING, LABELING, OR HOLDING OPERATIONS FOR DIETARY SUPPLEMENTS Production and Process Control... quality control operations, including written procedures for conducting a material review and making a...
VERIFICATION TESTING OF AIR POLLUTION CONTROL TECHNOLOGY QUALITY MANAGEMENT PLAN
This document is the basis for quality assurance for the Air Pollution Control Technology Verification Center (APCT Center) operated under the U.S. Environmental Protection Agency (EPA). It describes the policies, organizational structure, responsibilities, procedures, and qualit...
Reliability and quality assurance on the MOD 2 wind system
NASA Technical Reports Server (NTRS)
Mason, W. E. B.; Jones, B. G.
1981-01-01
The Safety, Reliability, and Quality Assurance (R&QA) approach developed for the largest wind turbine generator, the Mod 2, is described. The R&QA approach assures that the machine is not hazardous to the public or to the operating personnel, is operated unattended on a utility grid, demonstrates reliable operation, and helps establish the quality assurance and maintainability requirements for future wind turbine projects. The significant guideline consisted of a failure modes and effects analysis (FMEA) during the design phase, hardware inspections during parts fabrication, and three simple documents to control activities during machine construction and operation.
Robotic operation of the Observatorio Astrofísico de Javalambre
NASA Astrophysics Data System (ADS)
Yanes-Díaz, A.; Antón, J. L.; Rueda-Teruel, S.; Guillén-Civera, L.; Bello, R.; Jiménez-Mejías, D.; Chueca, S.; Lasso-Cabrera, N. M.; Suárez, O.; Rueda-Teruel, F.; Cenarro, A. J.; Cristóbal-Hornillos, D.; Marín-Franch, A.; Luis-Simoes, R.; López-Alegre, G.; Rodríguez-Hernández, M. A. C.; Moles, M.; Ederoclite, A.; Varela, J.; Vázquez Ramió, H.; Díaz-Martí, M. C.; Iglesias-Marzoa, R.; Maicas, N.; Lamadrid, J. L.; López-Sainz, A.; Hernández-Fuertes, J.; Valdivielso, L.
2015-05-01
The Observatorio Astrofísico de Javalambre (OAJ) is a new astronomical facility located at the Sierra de Javalambre (Teruel, Spain) whose primary role will be to conduct all-sky astronomical surveys with two unprecedented telescopes of unusually large fields of view: the JST/T250, a 2.55 m telescope of 3 deg field of view, and the JAST/T80, an 83 cm telescope of 2 deg field of view. CEFCA engineering team has been designing the OAJ control system as a global concept to manage, monitor, control and maintain all the observatory systems including not only astronomical subsystems but also infrastructure and other facilities. Three main factors have been considered in the design of a global control system for the robotic OAJ: quality, reliability and efficiency. We propose CIA (Control Integrated Architecture) design and OEE (Overall Equipment Effectiveness) as a key performance indicator in order to improve operation processes, minimizing resources and obtain high cost reduction maintaining quality requirements. Here we present the OAJ robotic control strategy to achieve maximum quality efficiency for the observatory surveys, processes and operations, giving practical examples of our approach.
Cloud Motion Vectors from MISR using Sub-pixel Enhancements
NASA Technical Reports Server (NTRS)
Davies, Roger; Horvath, Akos; Moroney, Catherine; Zhang, Banglin; Zhu, Yanqiu
2007-01-01
The operational retrieval of height-resolved cloud motion vectors by the Multiangle Imaging SpectroRadiometer on the Terra satellite has been significantly improved by using sub-pixel approaches to co-registration and disparity assessment, and by imposing stronger quality control based on the agreement between independent forward and aft triplet retrievals. Analysis of the fore-aft differences indicates that CMVs pass the basic operational quality control 67% of the time, with rms differences - in speed of 2.4 m/s, in direction of 17 deg, and in height assignment of 290 m. The use of enhanced quality control thresholds reduces these rms values to 1.5 m/s, 17 deg and 165 m, respectively, at the cost of reduced coverage to 45%. Use of the enhanced thresholds also eliminates a tendency for the rms differences to increase with height. Comparison of CMVs from an earlier operational version that had slightly weaker quality control, with 6-hour forecast winds from the Global Modeling and Assimilation Office yielded very low bias values and an rms vector difference that ranged from 5 m/s for low clouds to 10 m/s for high clouds.
ITS data quality control and the calculation of mobility performance measures
DOT National Transportation Integrated Search
2000-09-01
This report describes the results of research on the use of intelligent transportation system (ITS) data in calculating mobility performance measures for ITS operations. The report also describes a data quality control process developed for the Trans...
QUALITY CONTROL OF PHARMACEUTICALS.
LEVI, L; WALKER, G C; PUGSLEY, L I
1964-10-10
Quality control is an essential operation of the pharmaceutical industry. Drugs must be marketed as safe and therapeutically active formulations whose performance is consistent and predictable. New and better medicinal agents are being produced at an accelerated rate. At the same time more exacting and sophisticated analytical methods are being developed for their evaluation. Requirements governing the quality control of pharmaceuticals in accordance with the Canadian Food and Drugs Act are cited and discussed.
Taking advantage of ground data systems attributes to achieve quality results in testing software
NASA Technical Reports Server (NTRS)
Sigman, Clayton B.; Koslosky, John T.; Hageman, Barbara H.
1994-01-01
During the software development life cycle process, basic testing starts with the development team. At the end of the development process, an acceptance test is performed for the user to ensure that the deliverable is acceptable. Ideally, the delivery is an operational product with zero defects. However, the goal of zero defects is normally not achieved but is successful to various degrees. With the emphasis on building low cost ground support systems while maintaining a quality product, a key element in the test process is simulator capability. This paper reviews the Transportable Payload Operations Control Center (TPOCC) Advanced Spacecraft Simulator (TASS) test tool that is used in the acceptance test process for unmanned satellite operations control centers. The TASS is designed to support the development, test and operational environments of the Goddard Space Flight Center (GSFC) operations control centers. The TASS uses the same basic architecture as the operations control center. This architecture is characterized by its use of distributed processing, industry standards, commercial off-the-shelf (COTS) hardware and software components, and reusable software. The TASS uses much of the same TPOCC architecture and reusable software that the operations control center developer uses. The TASS also makes use of reusable simulator software in the mission specific versions of the TASS. Very little new software needs to be developed, mainly mission specific telemetry communication and command processing software. By taking advantage of the ground data system attributes, successful software reuse for operational systems provides the opportunity to extend the reuse concept into the test area. Consistency in test approach is a major step in achieving quality results.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-29
...; Cleaning of high precision optics; Stripping; Janitorial cleaning; cleaning of resin, coating, ink, and... laboratories; Cleaning operations in medical device or pharmaceutical manufacturing; and Cleaning operations related to performance or quality assurance testing of coatings, inks, or adhesives. COMAR 26.11.19.09-1...
Labby, Alex; Mace, Jess C; Buncke, Michelle; MacArthur, Carol J
2016-09-01
To evaluate quality-of-life changes after bilateral pressure equalization tube placement with or without adenoidectomy for the treatment of chronic otitis media with effusion or recurrent acute otitis media in a pediatric Down syndrome population compared to controls. Prospective case-control observational study. The OM Outcome Survey (OMO-22) was administered to both patients with Down syndrome and controls before bilateral tube placement with or without adenoidectomy and at an average of 6-7 months postoperatively. Thirty-one patients with Down syndrome and 34 controls were recruited. Both pre-operative and post-operative between-group and within-group score comparisons were conducted for the Physical, Hearing/Balance, Speech, Emotional, and Social domains of the OMO-22. Both groups experienced improvement of mean symptom scores post-operatively. Patients with Down syndrome reported significant post-operative improvement in mean Physical and Hearing domain item scores while control patients reported significant improvement in Physical, Hearing, and Emotional domain item scores. All four symptom scores in the Speech domain, both pre-operatively and post-operatively, were significantly worse for Down syndrome patients compared to controls (p ≤ 0.008). Surgical placement of pressure equalizing tubes results in significant quality of life improvements in patients with Down syndrome and controls. Problems related to speech and balance are reported at a higher rate and persist despite intervention in the Down syndrome population. It is possible that longer follow up periods and/or more sensitive tools are required to measure speech improvements in the Down syndrome population after pressure equalizing tube placement ± adenoidectomy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Assessing the structure of non-routine decision processes in Airline Operations Control.
Richters, Floor; Schraagen, Jan Maarten; Heerkens, Hans
2016-03-01
Unfamiliar severe disruptions challenge Airline Operations Control professionals most, as their expertise is stretched to its limits. This study has elicited the structure of Airline Operations Control professionals' decision process during unfamiliar disruptions by mapping three macrocognitive activities on the decision ladder: sensemaking, option evaluation and action planning. The relationship between this structure and decision quality was measured. A simulated task was staged, based on which think-aloud protocols were obtained. Results show that the general decision process structure resembles the structure of experts working under routine conditions, in terms of the general structure of the macrocognitive activities, and the rule-based approach used to identify options and actions. Surprisingly, high quality of decision outcomes was found to relate to the use of rule-based strategies. This implies that successful professionals are capable of dealing with unfamiliar problems by reframing them into familiar ones, rather than to engage in knowledge-based processing. Practitioner Summary: We examined the macrocognitive structure of Airline Operations Control professionals' decision process during a simulated unfamiliar disruption in relation to decision quality. Results suggest that successful professionals are capable of dealing with unfamiliar problems by reframing them into familiar ones, rather than to engage in knowledge-based processing.
ERIC Educational Resources Information Center
Turner, Ronald W.; And Others
Guidelines for controlling indoor air quality problems associated with kilns, copiers, and welding in schools are provided in this document. Individual sections on kilns, duplicating equipment, and welding operations contain information on the following: sources of contaminants; health effects; methods of control; ventilation strategies; and…
[Does ultraclean air in the operating room provide greater safety?].
van Tiel, Frank H; Buiting, Anton G; Meessen, Nico E L; Voss, Andreas; Vos, Margreet C
2010-01-01
The Dutch quality control plan for climatisation of the operating room (OR), which was published in 2005, describes the management and maintenance of the air conditioning system. This management plan proposes a standard for air quality in class 1 ORs. This has been adopted by the Dutch Orthopaedic Society, but not by other surgical societies. The British study which underlies the proposed norm for air quality in class 1 ORs, a study on the infection preventive effect of ultraclean air, dates from 1982 and is inadequately controlled for prophylactic use of antibiotics. Antibiotic prophylaxis in itself already reduces the number of surgical site infections.-More recent studies fail to show an infection preventive effect of ultraclean air in the OR. The Dutch Working Party for Infection Prevention (WIP) ought to take the initiative, together with the medical Scientific Societies and the Society of Infection Prevention and Control in the health care setting (VHIG), to establish enforceable norms for microbiological air quality and to set criteria as to which types of operations are allowed to be performed in which class of OR.
High-Performance Integrated Control of water quality and quantity in urban water reservoirs
NASA Astrophysics Data System (ADS)
Galelli, S.; Castelletti, A.; Goedbloed, A.
2015-11-01
This paper contributes a novel High-Performance Integrated Control framework to support the real-time operation of urban water supply storages affected by water quality problems. We use a 3-D, high-fidelity simulation model to predict the main water quality dynamics and inform a real-time controller based on Model Predictive Control. The integration of the simulation model into the control scheme is performed by a model reduction process that identifies a low-order, dynamic emulator running 4 orders of magnitude faster. The model reduction, which relies on a semiautomatic procedural approach integrating time series clustering and variable selection algorithms, generates a compact and physically meaningful emulator that can be coupled with the controller. The framework is used to design the hourly operation of Marina Reservoir, a 3.2 Mm3 storm-water-fed reservoir located in the center of Singapore, operated for drinking water supply and flood control. Because of its recent formation from a former estuary, the reservoir suffers from high salinity levels, whose behavior is modeled with Delft3D-FLOW. Results show that our control framework reduces the minimum salinity levels by nearly 40% and cuts the average annual deficit of drinking water supply by about 2 times the active storage of the reservoir (about 4% of the total annual demand).
Quality Control of Pharmaceuticals
Levi, Leo; Walker, George C.; Pugsley, L. I.
1964-01-01
Quality control is an essential operation of the pharmaceutical industry. Drugs must be marketed as safe and therapeutically active formulations whose performance is consistent and predictable. New and better medicinal agents are being produced at an accelerated rate. At the same time more exacting and sophisticated analytical methods are being developed for their evaluation. Requirements governing the quality control of pharmaceuticals in accordance with the Canadian Food and Drugs Act are cited and discussed. PMID:14199105
[Features of the maintenance of automated developing machines].
Koveshnikov, A I
1999-01-01
Based on his long-term own experience the author gives recommendations on the assembly, adjustment, operation, and preventive maintenance of automatic developing machines. Procedures are presented for evaluating the quality of X-ray films and controlling the activity of operating qualities of a developer while machining photographic materials. Troubles and malfunction of equipment and procedures for their elimination are shown to affect the quality of development of films.
An Improved Power Quality BIBRED Converter-Based VSI-Fed BLDC Motor Drive
NASA Astrophysics Data System (ADS)
Singh, Bhim; Bist, Vashist
2014-01-01
This paper presents an IHQRR (integrated high-quality rectifier regulator) BIBRED (boost integrated buck rectifier energy storage DC-DC) converter-based VSI (voltage source inverter)-fed BLDC (brushless DC) motor drive. The speed control of BLDC motor is achieved by controlling the DC link voltage of the VSI using a single voltage sensor. This allows VSI to operate in fundamental frequency switching mode for electronic commutation of BLDC motor which reduces the switching losses due to high-frequency switching used in conventional approach of PWM (pulse width modulation)-based VSI-fed BLDC motor drive. A BIBRED converter is operated in a dual-DCM (discontinuous conduction mode) thus using a voltage follower approach for PFC (power factor correction) and DC link voltage control. The performance of the proposed drive is evaluated for improved power quality over a wide range of speed control and supply voltage variation for demonstrating the behavior of proposed drive. The power quality indices thus obtained are within the recommended limits by international PQ (power quality) standards such as IEC 61000-3-2.
Orion Handling Qualities During ISS Proximity Operations and Docking
NASA Technical Reports Server (NTRS)
Stephens, John-Paul; Vos, Gordon A.; Bilimoria, Karl D.; Mueller, Eric R.; Brazzel, Jack; Spehar, Pete
2011-01-01
NASA's Orion spacecraft is designed to autonomously rendezvous and dock with many vehicles including the International Space Station. However, the crew is able to assume manual control of the vehicle s attitude and flight path. In these instances, Orion must meet handling qualities requirements established by NASA. Two handling qualities assessments were conducted at the Johnson Space Center to evaluate preliminary designs of the vehicle using a six degree of freedom, high-fidelity guidance, navigation, and control simulation. The first assessed Orion s handling qualities during the last 20 ft before docking, and included both steady and oscillatory motions of the docking target. The second focused on manual acquisition of the docking axis during the proximity operations phase and subsequent station-keeping. Cooper-Harper handling qualities ratings, workload ratings and comments were provided by 10 evaluation pilots for the docking study and 5 evaluation pilots for the proximity operations study. For the docking task, both cases received 90% Level 1 (satisfactory) handling qualities ratings, exceeding NASA s requirement. All ratings for the ProxOps task were Level 1. These evaluations indicate that Orion is on course to meet NASA's handling quality requirements for ProxOps and docking.
Importance of implementing an analytical quality control system in a core laboratory.
Marques-Garcia, F; Garcia-Codesal, M F; Caro-Narros, M R; Contreras-SanFeliciano, T
2015-01-01
The aim of the clinical laboratory is to provide useful information for screening, diagnosis and monitoring of disease. The laboratory should ensure the quality of extra-analytical and analytical process, based on set criteria. To do this, it develops and implements a system of internal quality control, designed to detect errors, and compare its data with other laboratories, through external quality control. In this way it has a tool to detect the fulfillment of the objectives set, and in case of errors, allowing corrective actions to be made, and ensure the reliability of the results. This article sets out to describe the design and implementation of an internal quality control protocol, as well as its periodical assessment intervals (6 months) to determine compliance with pre-determined specifications (Stockholm Consensus(1)). A total of 40 biochemical and 15 immunochemical methods were evaluated using three different control materials. Next, a standard operation procedure was planned to develop a system of internal quality control that included calculating the error of the analytical process, setting quality specifications, and verifying compliance. The quality control data were then statistically depicted as means, standard deviations, and coefficients of variation, as well as systematic, random, and total errors. The quality specifications were then fixed and the operational rules to apply in the analytical process were calculated. Finally, our data were compared with those of other laboratories through an external quality assurance program. The development of an analytical quality control system is a highly structured process. This should be designed to detect errors that compromise the stability of the analytical process. The laboratory should review its quality indicators, systematic, random and total error at regular intervals, in order to ensure that they are meeting pre-determined specifications, and if not, apply the appropriate corrective actions. Copyright © 2015 SECA. Published by Elsevier Espana. All rights reserved.
NASA Technical Reports Server (NTRS)
White, Preston A., III
1994-01-01
The Operational Television system at Kennedy Space Center operates hundreds of video cameras, many remotely controllable, in support of the operations at the center. This study was undertaken to determine if commercial NABTS (North American Basic Teletext System) teletext transmission in the vertical blanking interval of the genlock signals distributed to the cameras could be used to send remote control commands to the cameras and the associated pan and tilt platforms. Wavelength division multiplexed fiberoptic links are being installed in the OTV system to obtain RS-250 short-haul quality. It was demonstrated that the NABTS transmission could be sent over the fiberoptic cable plant without excessive video quality degradation and that video cameras could be controlled using NABTS transmissions over multimode fiberoptic paths as long as 1.2 km.
Santín, I; Barbu, M; Pedret, C; Vilanova, R
2018-06-01
The application of control strategies is increasingly used in wastewater treatment plants with the aim of improving effluent quality and reducing operating costs. Due to concerns about the progressive growth of greenhouse gas emissions (GHG), these are also currently being evaluated in wastewater treatment plants. The present article proposes a fuzzy controller for plant-wide control of the biological wastewater treatment process. Its design is based on 14 inputs and 6 outputs in order to reduce GHG emissions, nutrient concentration in the effluent and operational costs. The article explains and shows the effect of each one of the inputs and outputs of the fuzzy controller, as well as the relationship between them. Benchmark Simulation Model no 2 Gas is used for testing the proposed control strategy. The results of simulation results show that the fuzzy controller is able to reduce GHG emissions while improving, at the same time, the common criteria of effluent quality and operational costs. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.
The process of managerial control in quality improvement initiatives.
Slovensky, D J; Fottler, M D
1994-11-01
The fundamental intent of strategic management is to position an organization with in its market to exploit organizational competencies and strengths to gain competitive advantage. Competitive advantage may be achieved through such strategies as low cost, high quality, or unique services or products. For health care organizations accredited by the Joint Commission on Accreditation of Healthcare Organizations, continually improving both processes and outcomes of organizational performance--quality improvement--in all operational areas of the organization is a mandated strategy. Defining and measuring quality and controlling the quality improvement strategy remain problematic. The article discusses the nature and processes of managerial control, some potential measures of quality, and related information needs.
Controlled release fertilizer improves quality of container longleaf pine seedlings
R. Kasten Dumroese; Jeff Parkhurst; James P. Barnett
2005-01-01
In an operational trial, increasing the amount of nitrogen (N) applied to container longleaf pine seedlings by incorporating controlled release fertilizer (CRF) into the media improved seedling growth and quality. Compared with control seedlings that received 40 mg N, seedlings receiving 66 mg N through CRF supplemented with liquid fertilizer had needles that were 4 in...
Japanese style total quality control: A first hand experience
NASA Astrophysics Data System (ADS)
Cook, S. C.
1991-11-01
The scope, concepts and practices of Total Quality Control (TQC) as operated in Japan today are described. The following mechanisms and elements are introduced: policy deployment, cross functional management, small group activities, suggestion systems, standardization, the TQC promotion department, and TQC education. It is shown on a practical level, how TQC operates in the research and engineering divisions of the aeroengine and space operation at Ishikawajima Harima Industries in Japan. Japanese style TQC is a well developed, well promoted, well structured, common approach to achieving customer satisfaction through continuous improvements. Furthermore, TQC itself is being continuously improved with the Japanese still refining, extending, and developing TQC.
Integrated Neural Flight and Propulsion Control System
NASA Technical Reports Server (NTRS)
Kaneshige, John; Gundy-Burlet, Karen; Norvig, Peter (Technical Monitor)
2001-01-01
This paper describes an integrated neural flight and propulsion control system. which uses a neural network based approach for applying alternate sources of control power in the presence of damage or failures. Under normal operating conditions, the system utilizes conventional flight control surfaces. Neural networks are used to provide consistent handling qualities across flight conditions and for different aircraft configurations. Under damage or failure conditions, the system may utilize unconventional flight control surface allocations, along with integrated propulsion control, when additional control power is necessary for achieving desired flight control performance. In this case, neural networks are used to adapt to changes in aircraft dynamics and control allocation schemes. Of significant importance here is the fact that this system can operate without emergency or backup flight control mode operations. An additional advantage is that this system can utilize, but does not require, fault detection and isolation information or explicit parameter identification. Piloted simulation studies were performed on a commercial transport aircraft simulator. Subjects included both NASA test pilots and commercial airline crews. Results demonstrate the potential for improving handing qualities and significantly increasing survivability rates under various simulated failure conditions.
Real-time control of combined surface water quantity and quality: polder flushing.
Xu, M; van Overloop, P J; van de Giesen, N C; Stelling, G S
2010-01-01
In open water systems, keeping both water depths and water quality at specified values is critical for maintaining a 'healthy' water system. Many systems still require manual operation, at least for water quality management. When applying real-time control, both quantity and quality standards need to be met. In this paper, an artificial polder flushing case is studied. Model Predictive Control (MPC) is developed to control the system. In addition to MPC, a 'forward estimation' procedure is used to acquire water quality predictions for the simplified model used in MPC optimization. In order to illustrate the advantages of MPC, classical control [Proportional-Integral control (PI)] has been developed for comparison in the test case. The results show that both algorithms are able to control the polder flushing process, but MPC is more efficient in functionality and control flexibility.
Containing the Damage: Quality Control of Local Data Production.
ERIC Educational Resources Information Center
Blair, Norman A.
1983-01-01
The ability of operating departments of an institution to mechanically gather, summarize, and report "local" data is discussed. Problems are outlined that arise when departments have the ability to produce data and do so with rigorous quality control by the institution's central information management organization. (MLW)
NASA Astrophysics Data System (ADS)
Al Hadhrami, Tawfik; Nightingale, James M.; Wang, Qi; Grecos, Christos
2014-05-01
In emergency situations, the ability to remotely monitor unfolding events using high-quality video feeds will significantly improve the incident commander's understanding of the situation and thereby aids effective decision making. This paper presents a novel, adaptive video monitoring system for emergency situations where the normal communications network infrastructure has been severely impaired or is no longer operational. The proposed scheme, operating over a rapidly deployable wireless mesh network, supports real-time video feeds between first responders, forward operating bases and primary command and control centers. Video feeds captured on portable devices carried by first responders and by static visual sensors are encoded in H.264/SVC, the scalable extension to H.264/AVC, allowing efficient, standard-based temporal, spatial, and quality scalability of the video. A three-tier video delivery system is proposed, which balances the need to avoid overuse of mesh nodes with the operational requirements of the emergency management team. In the first tier, the video feeds are delivered at a low spatial and temporal resolution employing only the base layer of the H.264/SVC video stream. Routing in this mode is designed to employ all nodes across the entire mesh network. In the second tier, whenever operational considerations require that commanders or operators focus on a particular video feed, a `fidelity control' mechanism at the monitoring station sends control messages to the routing and scheduling agents in the mesh network, which increase the quality of the received picture using SNR scalability while conserving bandwidth by maintaining a low frame rate. In this mode, routing decisions are based on reliable packet delivery with the most reliable routes being used to deliver the base and lower enhancement layers; as fidelity is increased and more scalable layers are transmitted they will be assigned to routes in descending order of reliability. The third tier of video delivery transmits a high-quality video stream including all available scalable layers using the most reliable routes through the mesh network ensuring the highest possible video quality. The proposed scheme is implemented in a proven simulator, and the performance of the proposed system is numerically evaluated through extensive simulations. We further present an in-depth analysis of the proposed solutions and potential approaches towards supporting high-quality visual communications in such a demanding context.
Guidelines to implement quality management systems in microbiology laboratories for tissue banking.
Vicentino, W; Rodríguez, G; Saldías, M; Alvarez, I
2009-10-01
Human tissues for implants are a biomedical product that is being used more frequently by many medical disciplines. There are infections in the patients related to the implanted tissues. The early detection of infections transmitted by blood and the microbiological study of tissues before their clinical use are strategies in tissue banks to prevent these situations. This work sought to contribute to establish the bases for the operation of a laboratory applied to the microbiological quality control of tissues. Based on classical microbiological principles, we defined the operation of microbiological control and tissues sterilization since 2003. We determine lists of acceptable microorganisms for every tissue, criteria for the interpretation of results, and a diagnostic algorithm of microbiological quality. We observed that the circumstances of donor death can be a determinant of the quality. The environment and the operator should be investigated as probable sources of contamination in outbreaks. The criteria of work based on a solid methodology must help to avoid the transmission of infections between donor and recipient. This is a critical point in the quality management of a tissue bank.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-18
... chemical production and polytetrafluoroethylene operations; from paint, resin, and adhesive manufacturing... miscellaneous industrial adhesives control techniques guideline (CTG) category in accordance with the... to COMAR 26.11.19.30 ``Control of VOC from Chemical Production and Polytetrafluoroethylene Operations...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-29
... Promulgation of Air Quality Implementation Plans; Maryland; Control of Volatile Organic Compound Emissions From Industrial Solvent Cleaning Operations; Withdrawal of Direct Final Rule AGENCY: Environmental Protection... withdrawing the direct final rule to approve revisions to Maryland's State Implementation Plan (SIP). This SIP...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-22
... Promulgation of the Air Quality Implementation Plans; Maryland; Control of Volatile Organic Compound Emissions From Industrial Solvent Cleaning Operations AGENCY: Environmental Protection Agency (EPA). ACTION... Plan (SIP). The revision was submitted by the Maryland Department of the Environment (MDE) to establish...
Development of flying qualities criteria for single pilot instrument flight operations
NASA Technical Reports Server (NTRS)
Bar-Gill, A.; Nixon, W. B.; Miller, G. E.
1982-01-01
Flying qualities criteria for Single Pilot Instrument Flight Rule (SPIFR) operations were investigated. The ARA aircraft was modified and adapted for SPIFR operations. Aircraft configurations to be flight-tested were chosen and matched on the ARA in-flight simulator, implementing modern control theory algorithms. Mission planning and experimental matrix design were completed. Microprocessor software for the onboard data acquisition system was debugged and flight-tested. Flight-path reconstruction procedure and the associated FORTRAN program were developed. Algorithms associated with the statistical analysis of flight test results and the SPIFR flying qualities criteria deduction are discussed.
Boden, Ianthe; Browning, Laura; Skinner, Elizabeth H; Reeve, Julie; El-Ansary, Doa; Robertson, Iain K; Denehy, Linda
2015-12-15
Post-operative pulmonary complications are a significant problem following open upper abdominal surgery. Preliminary evidence suggests that a single pre-operative physiotherapy education and preparatory lung expansion training session alone may prevent respiratory complications more effectively than supervised post-operative breathing and coughing exercises. However, the evidence is inconclusive due to methodological limitations. No well-designed, adequately powered, randomised controlled trial has investigated the effect of pre-operative education and training on post-operative respiratory complications, hospital length of stay, and health-related quality of life following upper abdominal surgery. The Lung Infection Prevention Post Surgery - Major Abdominal- with Pre-Operative Physiotherapy (LIPPSMAck POP) trial is a pragmatic, investigator-initiated, bi-national, multi-centre, patient- and assessor-blinded, parallel group, randomised controlled trial, powered for superiority. Four hundred and forty-one patients scheduled for elective open upper abdominal surgery at two Australian and one New Zealand hospital will be randomised using concealed allocation to receive either i) an information booklet or ii) an information booklet, plus one additional pre-operative physiotherapy education and training session. The primary outcome is respiratory complication incidence using standardised diagnostic criteria. Secondary outcomes include hospital length of stay and costs, pneumonia diagnosis, intensive care unit readmission and length of stay, days/h to mobilise >1 min and >10 min, and, at 6 weeks post-surgery, patient reported complications, health-related quality of life, and physical capacity. The LIPPSMAck POP trial is a multi-centre randomised controlled trial powered and designed to investigate whether a single pre-operative physiotherapy session prevents post-operative respiratory complications. This trial standardises post-operative assisted ambulation and physiotherapy, measures many known confounders, and includes a post-discharge follow-up of complication rates, functional capacity, and health-related quality of life. This trial is currently recruiting. Australian New Zealand Clinical Trials Registry number: ACTRN12613000664741 , 19 June 2013.
NASA Technical Reports Server (NTRS)
Powers, B. G.
1972-01-01
The magnitude and frequency of occurrence of aircraft responses and control inputs during 27 flights of the XB-70 airplane were measured. Exceedance curves are presented for the airplane responses and control usage. A technique is presented which makes use of these exceedance curves to establish or verify handling qualities criteria. This technique can provide a means of incorporating current operational experience in handling qualities requirements for future aircraft.
Analysis And Control System For Automated Welding
NASA Technical Reports Server (NTRS)
Powell, Bradley W.; Burroughs, Ivan A.; Kennedy, Larry Z.; Rodgers, Michael H.; Goode, K. Wayne
1994-01-01
Automated variable-polarity plasma arc (VPPA) welding apparatus operates under electronic supervision by welding analysis and control system. System performs all major monitoring and controlling functions. It acquires, analyzes, and displays weld-quality data in real time and adjusts process parameters accordingly. Also records pertinent data for use in post-weld analysis and documentation of quality. System includes optoelectronic sensors and data processors that provide feedback control of welding process.
Nitrosi, Andrea; Bertolini, Marco; Borasi, Giovanni; Botti, Andrea; Barani, Adriana; Rivetti, Stefano; Pierotti, Luisa
2009-12-01
Ideally, medical x-ray imaging systems should be designed to deliver maximum image quality at an acceptable radiation risk to the patient. Quality assurance procedures are employed to ensure that these standards are maintained. A quality control protocol for direct digital radiography (DDR) systems is described and discussed. Software to automatically process and analyze the required images was developed. In this paper, the initial results obtained on equipment of different DDR manufacturers were reported. The protocol was developed to highlight even small discrepancies in standard operating performance.
43 CFR 23.5 - Technical examination of prospective surface exploration and mining operations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... mining operations vary widely with respect to topography, climate, surrounding land uses, proximity to... lowering of water quality below standards established by the appropriate State water pollution control... to the State water pollution control agency and to the Department of the Interior that such lowering...
43 CFR 23.5 - Technical examination of prospective surface exploration and mining operations.
Code of Federal Regulations, 2013 CFR
2013-10-01
... mining operations vary widely with respect to topography, climate, surrounding land uses, proximity to... lowering of water quality below standards established by the appropriate State water pollution control... to the State water pollution control agency and to the Department of the Interior that such lowering...
43 CFR 23.5 - Technical examination of prospective surface exploration and mining operations.
Code of Federal Regulations, 2011 CFR
2011-10-01
... mining operations vary widely with respect to topography, climate, surrounding land uses, proximity to... lowering of water quality below standards established by the appropriate State water pollution control... to the State water pollution control agency and to the Department of the Interior that such lowering...
43 CFR 23.5 - Technical examination of prospective surface exploration and mining operations.
Code of Federal Regulations, 2014 CFR
2014-10-01
... mining operations vary widely with respect to topography, climate, surrounding land uses, proximity to... lowering of water quality below standards established by the appropriate State water pollution control... to the State water pollution control agency and to the Department of the Interior that such lowering...
Lucchetti, G.; Gray, G.A.
1988-01-01
A small-scale water reuse system (150 L/min) was developed to create an environment for observing fish under a variety of temperature regimes. Key concerns of disease control, water quality, temperature control, and efficiency and case of operation were addressed. Northern squawfish (Ptychocheilus oregonensis) were held at loading densities ranging from 0.11 to 0.97 kg/L per minute and at temperatures from 10 to 20°C for 6 months with no disease problems or degradation ofwater quality in the system. The system required little maintenance during 2 years of operation.
NASA Technical Reports Server (NTRS)
Rising, J. J.; Kairys, A. A.; Maass, C. A.; Siegart, C. D.; Rakness, W. L.; Mijares, R. D.; King, R. W.; Peterson, R. S.; Hurley, S. R.; Wickson, D.
1982-01-01
A limited authority pitch active control system (PACS) was developed for a wide body jet transport (L-1011) with a flying horizontal stabilizer. Two dual channel digital computers and the associated software provide command signals to a dual channel series servo which controls the stabilizer power actuators. Input sensor signals to the computer are pitch rate, column-trim position, and dynamic pressure. Control laws are given for the PACS and the system architecture is defined. The piloted flight simulation and vehicle system simulation tests performed to verify control laws and system operation prior to installation on the aircraft are discussed. Modifications to the basic aircraft are described. Flying qualities of the aircraft with the PACS on and off were evaluated. Handling qualities for cruise and high speed flight conditions with the c.g. at 39% mac ( + 1% stability margin) and PACS operating were judged to be as good as the handling qualities with the c.g. at 25% (+15% stability margin) and PACS off.
Data Assimilation Experiments using Quality Controlled AIRS Version 5 Temperature Soundings
NASA Technical Reports Server (NTRS)
SUsskind, Joel
2008-01-01
The AIRS Science Team Version 5 retrieval algorithm has been finalized and is now operational at the Goddard DAAC in the processing (and reprocessing) of all AIRS data. The AIRS Science Team Version 5 retrieval algorithm contains two significant improvements over Version 4: 1) Improved physics allows for use of AIRS observations in the entire 4.3 pm C02 absorption band in the retrieval of temperature profile T(p) during both day and night. Tropospheric sounding 15 pm C02 observations are now used primarily in the generation of cloud cleared radiances Ri. This approach allows for the generation of accurate values of Ri and T(p) under most cloud conditions. 2) Another very significant improvement in Version 5 is the ability to generate accurate case-by-case, level-by-level error estimates for the atmospheric temperature profile, as well as for channel-by- channel error estimates for Ri. These error estimates are used for quality control of the retrieved products. We have conducted forecast impact experiments assimilating AIRS temperature profiles with different levels of quality control using the NASA GEOS-5 data assimilation system. Assimilation of quality controlled T(p) resulted in significantly improved forecast skill compared to that obtained from analyses obtained when all data used operationally by NCEP, except for AIRS data, is assimilated. We also conducted an experiment assimilating AIRS radiances uncontaminated by clouds, as done Operationally by ECMWF and NCEP. Forecasts resulting from assimilated AIRS radiances were of poorer quality than those obtained assimilating AIRS temperatures.
The Status of the Quality Control in Acupuncture-Neuroimaging Studies
Qiu, Ke; Jing, Miaomiao; Liu, Xiaoyan; Gao, Feifei; Liang, Fanrong; Zeng, Fang
2016-01-01
Using neuroimaging techniques to explore the central mechanism of acupuncture gains increasing attention, but the quality control of acupuncture-neuroimaging study remains to be improved. We searched the PubMed Database during 1995 to 2014. The original English articles with neuroimaging scan performed on human beings were included. The data involved quality control including the author, sample size, characteristics of the participant, neuroimaging technology, and acupuncture intervention were extracted and analyzed. The rigorous inclusion and exclusion criteria are important guaranty for the participants' homogeneity. The standard operation process of acupuncture and the stricter requirement for acupuncturist play significant role in quality control. More attention should be paid to the quality control in future studies to improve the reproducibility and reliability of the acupuncture-neuroimaging studies. PMID:27242911
Impact of longitudinal flying qualities upon the design of a transport with active controls
NASA Technical Reports Server (NTRS)
Sliwa, S. M.
1980-01-01
Direct constrained parameter optimization was used to optimally size a medium range transport for minimum direct operating cost. Several stability and control constraints were varied to study the sensitivity of the configuration to specifying the unaugmented flying qualities of transports designed with relaxed static stability. Additionally, a number of handling quality related design constants were studied with respect to their impact to the design.
A Quality-Control-Oriented Database for a Mesoscale Meteorological Observation Network
NASA Astrophysics Data System (ADS)
Lussana, C.; Ranci, M.; Uboldi, F.
2012-04-01
In the operational context of a local weather service, data accessibility and quality related issues must be managed by taking into account a wide set of user needs. This work describes the structure and the operational choices made for the operational implementation of a database system storing data from highly automated observing stations, metadata and information on data quality. Lombardy's environmental protection agency, ARPA Lombardia, manages a highly automated mesoscale meteorological network. A Quality Assurance System (QAS) ensures that reliable observational information is collected and disseminated to the users. The weather unit in ARPA Lombardia, at the same time an important QAS component and an intensive data user, has developed a database specifically aimed to: 1) providing quick access to data for operational activities and 2) ensuring data quality for real-time applications, by means of an Automatic Data Quality Control (ADQC) procedure. Quantities stored in the archive include hourly aggregated observations of: precipitation amount, temperature, wind, relative humidity, pressure, global and net solar radiation. The ADQC performs several independent tests on raw data and compares their results in a decision-making procedure. An important ADQC component is the Spatial Consistency Test based on Optimal Interpolation. Interpolated and Cross-Validation analysis values are also stored in the database, providing further information to human operators and useful estimates in case of missing data. The technical solution adopted is based on a LAMP (Linux, Apache, MySQL and Php) system, constituting an open source environment suitable for both development and operational practice. The ADQC procedure itself is performed by R scripts directly interacting with the MySQL database. Users and network managers can access the database by using a set of web-based Php applications.
40 CFR Appendix B to Part 425 - Modified Monier-Williams Method
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Modified Monier-Williams Method B... Appendix B to Part 425—Modified Monier-Williams Method Outline of Method Hydrogen sulfide is liberated from.... Quality Control 1. Each laboratory that uses this method is required to operate a formal quality control...
40 CFR Appendix B to Part 425 - Modified Monier-Williams Method
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Modified Monier-Williams Method B... Part 425—Modified Monier-Williams Method Outline of Method Hydrogen sulfide is liberated from an.... Quality Control 1. Each laboratory that uses this method is required to operate a formal quality control...
40 CFR Appendix B to Part 425 - Modified Monier-Williams Method
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Modified Monier-Williams Method B... Part 425—Modified Monier-Williams Method Outline of Method Hydrogen sulfide is liberated from an.... Quality Control 1. Each laboratory that uses this method is required to operate a formal quality control...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-22
... Pollution, submitted to EPA by the Puerto Rico Environmental Quality Board on July 13, 2011. This action...)(2).) List of Subjects 40 CFR Part 52 Environmental protection, Air pollution control, Incorporation... Control of Atmospheric Pollution submitted on July 13, 2011 by the Puerto Rico Environmental Quality Board...
The Quality Control Circle: Is It for Education?
ERIC Educational Resources Information Center
Land, Arthur J.
From its start in Japan after World War II, the Quality Control Circle (Q.C.) approach to management and organizational operation evolved into what it is today: people doing similar work meeting regularly to identify, objectively analyze, and develop solutions to problems. The Q.C. approach meets Maslow's theory of motivation by inviting…
Rhetoric and Realities in Today's ICF/MR: Control out of Control.
ERIC Educational Resources Information Center
Holburn, C. Steve
1992-01-01
This paper contrasts the rhetoric of quality assurance with the realities of poor quality in today's Intermediate Care Facilities for the Mentally Retarded (ICF/MR). The ICF/MR operational model is described as paper oriented, failure based, and insensitive to the effects of its own practices. Recommendations include the establishment of local…
Causes of Indoor Air Quality Problems in Schools: Summary of Scientific Research. Revised Edition.
ERIC Educational Resources Information Center
Bayer, Charlene W.; Crow, Sidney A.; Fischer, John
Understanding the primary causes of indoor air quality (IAQ) problems and how controllable factors--proper heating, ventilation and air-conditioning (HVAC) system design, allocation of adequate outdoor air, proper filtration, effective humidity control, and routine maintenance--can avert problems may help all building owners, operators, and…
21 CFR 111.140 - Under this subpart F, what records must you make and keep?
Code of Federal Regulations, 2010 CFR
2010-04-01
... and making a disposition decision and written procedures for approving or rejecting any reprocessing... perform the quality control operation, who conducted the material review and made the disposition decision... System: Requirements for Quality Control § 111.140 Under this subpart F, what records must you make and...
Math Problems for Water Quality Control Personnel, Student Workbook. Second Edition.
ERIC Educational Resources Information Center
Delvecchio, Fred; Brutsch, Gloria
This document is the student workbook for a course in mathematics for water quality control personnel. This version contains complete problems, answers and references. Problems are arranged alphabetically by treatment process. Charts, graphs, and drawings represent data forms an operator might see in a plant containing information necessary for…
Cost-benefit analysis of different air change rates in an operating room environment.
Gormley, Thomas; Markel, Troy A; Jones, Howard; Greeley, Damon; Ostojic, John; Clarke, James H; Abkowitz, Mark; Wagner, Jennifer
2017-12-01
Hospitals face growing pressure to meet the dual but often competing goals of providing a safe environment while controlling operating costs. Evidence-based data are needed to provide insight for facility management practices to support these goals. The quality of the air in 3 operating rooms was measured at different ventilation rates. The energy cost to provide the heating, ventilation, and air conditioning to the rooms was estimated to provide a cost-benefit comparison of the effectiveness of different ventilation rates currently used in the health care industry. Simply increasing air change rates in the operating rooms tested did not necessarily provide an overall cleaner environment, but did substantially increase energy consumption and costs. Additionally, and unexpectedly, significant differences in microbial load and air velocity were detected between the sterile fields and back instrument tables. Increasing the ventilation rates in operating rooms in an effort to improve clinical outcomes and potentially reduce surgical site infections does not necessarily provide cleaner air, but does typically increase operating costs. Efficient distribution or management of the air can improve quality indicators and potentially reduce the number of air changes required. Measurable environmental quality indicators could be used in lieu of or in addition to air change rate requirements to optimize cost and quality for an operating room and other critical environments. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Grantham, William D.; Person, Lee H., Jr.; Brown, Philip W.; Becker, Lawrence E.; Hunt, George E.; Rising, J. J.; Davis, W. J.; Willey, C. S.; Weaver, W. A.; Cokeley, R.
1985-01-01
Piloted simulation studies have been conducted to evaluate the effectiveness of two pitch active control systems (PACS) on the flying qualities of a wide-body transport airplane when operating at negative static margins. These two pitch active control systems consisted of a simple 'near-term' PACS and a more complex 'advanced' PACS. Eight different flight conditions, representing the entire flight envelope, were evaluated with emphasis on the cruise flight conditions. These studies were made utilizing the Langley Visual/Motion Simulator (VMS) which has six degrees of freedom. The simulation tests indicated that (1) the flying qualities of the baseline aircraft (PACS off) for the cruise and other high-speed flight conditions were unacceptable at center-of-gravity positions aft of the neutral static stability point; (2) within the linear static stability flight envelope, the near-term PACS provided acceptable flying qualities for static stabilty margins to -3 percent; and (3) with the advanced PACS operative, the flying qualities were demonstrated to be good (satisfactory to very acceptable) for static stabilty margins to -20 percent.
1982-02-01
AD A113 .5. ORANGE COUNTY POLLUTION CONTROL DEPT ORLANDO FL F/S 6/6 LARGE-SCALE OPERATIONS MANAGEMENT TEST OF USE OF THE WHITE AMUR-ETC(U) FEB 82 H D...Large-Scale Operations Management Test of use of the white amur for control of problem aquatic plants in Lake Conway, Fla. Report 1 of the series presents...as follows: Miller, D. 1982. "Large-Scale Operations Management Test of Use of the White Amur for Control of Problem Aquatic Plants; Report 2, First
1982-08-01
AD-A-11 701 ORANGE COUNTY POLLUTION CONTROL DEPT ORLANDO FL F/0 6/6 LARGE-SCALE OPERATIONS MANAGEMENT TEST OF USE OF THE WHITE AMUR--ETC(U) AUG 82 H...8217 OPERATIONS MANAGEMENT TEST OF USE OF THE WHITE AMUR FOR CONTROL -OF PROBLEM AQ.UATIC PLANTS SECOND YEAR POSTSTOCKING RESULTS Volume, Vt The Water...and Subetie) S. TYPE OF REPORT & PERIOD COVERED LARGE-SCALE OPERATIONS MANAGEMENT TEST OF USE OF Report 3 of a series THE WHITE AMUR FOR CONTROL OF
21 CFR 111.12 - What personnel qualification requirements apply?
Code of Federal Regulations, 2014 CFR
2014-04-01
..., PACKAGING, LABELING, OR HOLDING OPERATIONS FOR DIETARY SUPPLEMENTS Personnel § 111.12 What personnel... dietary supplements. (b) You must identify who is responsible for your quality control operations. Each...
21 CFR 111.12 - What personnel qualification requirements apply?
Code of Federal Regulations, 2012 CFR
2012-04-01
..., PACKAGING, LABELING, OR HOLDING OPERATIONS FOR DIETARY SUPPLEMENTS Personnel § 111.12 What personnel... dietary supplements. (b) You must identify who is responsible for your quality control operations. Each...
Quality assurance program requirements, Amendment 5 (9-26-79) to August 1973 issue
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This standard sets forth general requirements for planning, managing, conducting, and evaluating quality assurance programs for reactor development and test facility projects and associated processes, structures, components, and systems. These quality assurance requirements are based on proven practices and provide the means of control and verification whereby those responsible fo poject management can assure that the quality required for safe, reliable, and economical operation will be achieved. The objective of the program of the programs covered by this standard is to assure that structures, components, systems, and facilities are designed, developed, manufactured, constructed, operated, and maintained in compliance with establishedmore » engineering criteria. To achieve this objective, controls are to be established and implemented at predetermined points, and necessary action taken to prevent, detect, and correct any deficiencies.« less
Lee, JuneHyuck; Noh, Sang Do; Kim, Hyun-Jung; Kang, Yong-Shin
2018-05-04
The prediction of internal defects of metal casting immediately after the casting process saves unnecessary time and money by reducing the amount of inputs into the next stage, such as the machining process, and enables flexible scheduling. Cyber-physical production systems (CPPS) perfectly fulfill the aforementioned requirements. This study deals with the implementation of CPPS in a real factory to predict the quality of metal casting and operation control. First, a CPPS architecture framework for quality prediction and operation control in metal-casting production was designed. The framework describes collaboration among internet of things (IoT), artificial intelligence, simulations, manufacturing execution systems, and advanced planning and scheduling systems. Subsequently, the implementation of the CPPS in actual plants is described. Temperature is a major factor that affects casting quality, and thus, temperature sensors and IoT communication devices were attached to casting machines. The well-known NoSQL database, HBase and the high-speed processing/analysis tool, Spark, are used for IoT repository and data pre-processing, respectively. Many machine learning algorithms such as decision tree, random forest, artificial neural network, and support vector machine were used for quality prediction and compared with R software. Finally, the operation of the entire system is demonstrated through a CPPS dashboard. In an era in which most CPPS-related studies are conducted on high-level abstract models, this study describes more specific architectural frameworks, use cases, usable software, and analytical methodologies. In addition, this study verifies the usefulness of CPPS by estimating quantitative effects. This is expected to contribute to the proliferation of CPPS in the industry.
Operational CryoSat Product Quality Assessment
NASA Astrophysics Data System (ADS)
Mannan, Rubinder; Webb, Erica; Hall, Amanda; Bouzinac, Catherine
2013-12-01
The performance and quality of the CryoSat data products are routinely assessed by the Instrument Data quality Evaluation and Analysis Service (IDEAS). This information is then conveyed to the scientific and user community in order to allow them to utilise CryoSat data with confidence. This paper presents details of the Quality Control (QC) activities performed for CryoSat products under the IDEAS contract. Details of the different QC procedures and tools deployed by IDEAS to assess the quality of operational data are presented. The latest updates to the Instrument Processing Facility (IPF) for the Fast Delivery Marine (FDM) products and the future update to Baseline-C are discussed.
Historical overview of V/STOL aircraft technology
NASA Technical Reports Server (NTRS)
Anderson, S. B.
1981-01-01
The requirements for satisfactory characteristics in several key technology areas are discussed and a review is made of various V/STOL aircraft for the purpose of assessing the success or failure of each design in meeting design requirements. Special operating techniques were developed to help circumvent deficiencies. For the most part performance and handling qualities limitations restricted operational evaluations. Flight operations emphasized the need for good STOL performance, good handling qualities, and stability and control augmentation. The majority of aircraft suffered adverse ground effects.
1988-03-01
operators recommendations, certain select individuals are trained and used as SPC technicians. " POKA - YOKE " or mistake proofing from Shiegeo Shingo’s "Zero...Quality Control: Source Inspection and the POKA - YOKE System" has been locally applied to operators processes with great success. This pre-control
Accreditation and quality approach in operating theatre departments: the French approach.
Soudée, M
2005-01-01
Since 1996, French health establishments are subjected to a process of evaluating the quality of care, called "accreditation". This process was controlled by ANAES, which, after January 1st, 2005 became the Haute Autorité de Santé (HAS). The accreditation is characterized by a dual process of self-assessment and external audit, leading to four levels of accreditation. In spite of requiring a time-consuming methodology, this approach provides an important means of consolidating the development of the quality approach and re-stimulating the compliance of establishments with standards of safety and vigilance. The professional teams of many French operating theatre departments have been able to use the regulatory and restricting framework of accreditation to organize quality approaches specific to the operative system, supported by the organizational structures of the department such as the operating suite committee, departmental boards and the steering group. Based on quality guidelines including a commitment from the manager and operating suite committee, as well as a quality flow chart and a quality system, these teams describe the main procedures for running the operating theatre. They also organize the follow-up of incidents and undesirable events, along with the risks and points to watch. Audits of the operative system are planned on a regular basis. The second version of the accreditation process considerably reinforces the assessment of professional practices by evaluating the relevance, the risks and the methods of managing care for pathologies. It will make it possible to implement assessments of the health care provided by operating theatre departments and will reinforce the importance of search for quality.
Optimum operation of restoration techniques for eutrophic water bodies
NASA Astrophysics Data System (ADS)
Hagen, N. M.; Kleeberg, H.-B.
1994-05-01
Operating rules have been applied in water resources management for a long time in order to control and supply a required quantity (volume) of water. The operating rules have to guarantee the optimum management of the reservoir(s). The quality of the stored water has been satisfactory for the desired utilization up to the sixties. Due to the deterioration of reservoir water quality through human impacts, however, increased attention had to be paid since. Eutrophication of stagnant waters is still an unsolved problem. Through means of various restoration techniques, i.e., dilution/flushing or hypolimnetic withdrawal, the quality of the stored water can be improved. Continuous operation or appropriate time or depth variant operating rules are required to achieve this goal. The paper presents such rules for long-term operation. They have been established for the first time and can he represented in two or three-dimensional graphs depending on the number of included components (e.g., actual water storage and quality). The ‘quality operating rules’ take into account the dynamics of the processes in aquatic ecosystems. Simplifications with regard to application and acceptance (e.g., clarity) are developed and tested. The general validity and efficiency of the operating rules have been proved in a case study (a multi-purpose reservoir) and a fictitious lake.
An Application of Six Sigma to Reduce Supplier Quality Cost
NASA Astrophysics Data System (ADS)
Gaikwad, Lokpriya Mohanrao; Teli, Shivagond Nagappa; Majali, Vijay Shashikant; Bhushi, Umesh Mahadevappa
2016-01-01
This article presents an application of Six Sigma to reduce supplier quality cost in manufacturing industry. Although there is a wider acceptance of Six Sigma in many organizations today, there is still a lack of in-depth case study of Six Sigma. For the present research the case study methodology was used. The company decided to reduce quality cost and improve selected processes using Six Sigma methodologies. Regarding the fact that there is a lack of case studies dealing with Six Sigma especially in individual manufacturing organization this article could be of great importance also for the practitioners. This paper discusses the quality and productivity improvement in a supplier enterprise through a case study. The paper deals with an application of Six Sigma define-measure-analyze-improve-control methodology in an industry which provides a framework to identify, quantify and eliminate sources of variation in an operational process in question, to optimize the operation variables, improve and sustain performance viz. process yield with well-executed control plans. Six Sigma improves the process performance (process yield) of the critical operational process, leading to better utilization of resources, decreases variations and maintains consistent quality of the process output.
Programmable Positioner For Spot Welding
NASA Technical Reports Server (NTRS)
Roden, William A.
1989-01-01
Welding station mechanized by installing preset indexing system and gear drive. Mechanism includes a low-cost, versatile, single-axis motion control and motor drive to provide fully-automatic weld sequencing and spot-to-spot spacing. Welding station relieves operator of some difficult, tedious tasks and increases both productivity and quality of welds. Results in welds of higher quality and greater accuracy, fewer weld defects, and faster welding operation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ding, Fei; Nagarajan, Adarsh; Chakraborty, Sudipta
This report presents an impact assessment study of distributed photovoltaic (PV) with smart inverter Volt-VAR control on conservation voltage reduction (CVR) energy savings and distribution system power quality. CVR is a methodology of flattening and lowering a distribution system voltage profile in order to conserve energy. Traditional CVR relies on operating utility voltage regulators and switched capacitors. However, with the increased penetration of distributed PV systems, smart inverters provide the new opportunity to control local voltage and power factor by regulating the reactive power output, leading to a potential increase in CVR energy savings. This report proposes a methodology tomore » implement CVR scheme by operating voltage regulators, capacitors, and autonomous smart inverter Volt-VAR control in order to achieve increased CVR benefit. Power quality is an important consideration when operating a distribution system, especially when implementing CVR. It is easy to measure the individual components that make up power quality, but a comprehensive method to incorporate all of these values into a single score has yet to be undertaken. As a result, this report proposes a power quality scoring mechanism to measure the relative power quality of distribution systems using a single number, which is aptly named the 'power quality score' (PQS). Both the CVR and PQS methodologies were applied to two distribution system models, one obtained from the Hawaiian Electric Company (HECO) and another obtained from Pacific Gas and Electric (PG&E). These two models were converted to the OpenDSS platform using previous model conversion tools that were developed by NREL. Multiple scenarios including various PV penetration levels and smart inverter densities were simulated to analyze the impact of smart inverter Volt-VAR support on CVR energy savings and feeder power quality. In order to analyze the CVR benefit and PQS, an annual simulation was conducted for each scenario.« less
The US National Transonic Facility, NTF
NASA Technical Reports Server (NTRS)
Bruce, Walter E., Jr.; Gloss, Blair B.
1989-01-01
The construction of the National Transonic Facility was completed in September 1982 and the start-up and checkout of tunnel systems were performed over the next two years. In August 1984, the Operational Readiness Review (ORR) was conducted and the facility was declared operational for final checkout of cryogenic instrumentation and control systems, and for the aerodynamic calibration and testing to commence. Also, the model access system for the cryogenic mode of operation would be placed into operation along with tunnel testing. Since the ORR, a host of operating problems resulting from the cryogenic environment were identified and solved. These range from making mechanical and electrical systems functional to eliminating temperature induced model vibration to coping with the outgassing of moisture from the thermal insulation. Additionally, a series of aerodynamic tests have demonstrated data quality and provided research data on several configurations. Some of the more significant efforts are reviewed since the ORR and the NTF status concerning hardware, instrumentation and process controls systems, operating constraints imposed by the cryogenic environment, and data quality are summarized.
A Validity-Based Approach to Quality Control and Assurance of Automated Scoring
ERIC Educational Resources Information Center
Bejar, Isaac I.
2011-01-01
Automated scoring of constructed responses is already operational in several testing programmes. However, as the methodology matures and the demand for the utilisation of constructed responses increases, the volume of automated scoring is likely to increase at a fast pace. Quality assurance and control of the scoring process will likely be more…
NASA Technical Reports Server (NTRS)
Mahmot, Ron; Koslosky, John T.; Beach, Edward; Schwarz, Barbara
1994-01-01
The Mission Operations Division (MOD) at Goddard Space Flight Center builds Mission Operations Centers which are used by Flight Operations Teams to monitor and control satellites. Reducing system life cycle costs through software reuse has always been a priority of the MOD. The MOD's Transportable Payload Operations Control Center development team established an extensive library of 14 subsystems with over 100,000 delivered source instructions of reusable, generic software components. Nine TPOCC-based control centers to date support 11 satellites and achieved an average software reuse level of more than 75 percent. This paper shares experiences of how the TPOCC building blocks were developed and how building block developer's, mission development teams, and users are all part of the process.
Waste Water Plant Operators Manual.
ERIC Educational Resources Information Center
Washington State Coordinating Council for Occupational Education, Olympia.
This manual for sewage treatment plant operators was prepared by a committee of operators, educators, and engineers for use as a reference text and handbook and to serve as a training manual for short course and certification programs. Sewage treatment plant operators have a responsibility in water quality control; they are the principal actors in…
Methodology for analyzing environmental quality indicators in a dynamic operating room environment.
Gormley, Thomas; Markel, Troy A; Jones, Howard W; Wagner, Jennifer; Greeley, Damon; Clarke, James H; Abkowitz, Mark; Ostojic, John
2017-04-01
Sufficient quantities of quality air and controlled, unidirectional flow are important elements in providing a safe building environment for operating rooms. To make dynamic assessments of an operating room environment, a validated method of testing the multiple factors influencing the air quality in health care settings needed to be constructed. These include the following: temperature, humidity, particle load, number of microbial contaminants, pressurization, air velocity, and air distribution. The team developed the name environmental quality indicators (EQIs) to describe the overall air quality based on the actual measurements of these properties taken during the mock surgical procedures. These indicators were measured at 3 different hospitals during mock surgical procedures to simulate actual operating room conditions. EQIs included microbial assessments at the operating table and the back instrument table and real-time analysis of particle counts at 9 different defined locations in the operating suites. Air velocities were measured at the face of the supply diffusers, at the sterile field, at the back table, and at a return grille. The testing protocol provided consistent and comparable measurements of air quality indicators between institutions. At 20 air changes per hour (ACH), and an average temperature of 66.3°F, the median of the microbial contaminants for the 3 operating room sites ranged from 3-22 colony forming units (CFU)/m 3 at the sterile field and 5-27 CFU/m 3 at the back table. At 20 ACH, the median levels of the 0.5-µm particles at the 3 sites were 85,079, 85,325, and 912,232 in particles per cubic meter, with a predictable increase in particle load in the non-high-efficiency particulate air-filtered operating room site. Using a comparison with cleanroom standards, the microbial and particle counts in all 3 operating rooms were equivalent to International Organization for Standardization classifications 7 and 8 during the mock surgical procedures. The EQI protocol was measurable and repeatable and therefore can be safely used to evaluate air quality within the health care environment to provide guidance for operational practices and regulatory requirements. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Experience with modified aerospace reliability and quality assurance method for wind turbines
NASA Technical Reports Server (NTRS)
Klein, W. E.
1982-01-01
The SR&QA approach assures that the machine is not hazardous to the public or operating personnel, can operate unattended on a utility grid, demonstrates reliability operation, and helps establish the quality assurance and maintainability requirements for future wind turbine projects. The approach consisted of modified failure modes and effects analysis (FMEA) during the design phase, minimal hardware inspection during parts fabrication, and three simple documents to control activities during machine construction and operation. Five years experience shows that this low cost approach works well enough that it should be considered by others for similar projects.
Li, Mingjie; Zhou, Ping; Wang, Hong; ...
2017-09-19
As one of the most important unit in the papermaking industry, the high consistency (HC) refining system is confronted with challenges such as improving pulp quality, energy saving, and emissions reduction in its operation processes. Here in this correspondence, an optimal operation of HC refining system is presented using nonlinear multiobjective model predictive control strategies that aim at set-point tracking objective of pulp quality, economic objective, and specific energy (SE) consumption objective, respectively. First, a set of input and output data at different times are employed to construct the subprocess model of the state process model for the HC refiningmore » system, and then the Wiener-type model can be obtained through combining the mechanism model of Canadian Standard Freeness and the state process model that determines their structures based on Akaike information criterion. Second, the multiobjective optimization strategy that optimizes both the set-point tracking objective of pulp quality and SE consumption is proposed simultaneously, which uses NSGA-II approach to obtain the Pareto optimal set. Furthermore, targeting at the set-point tracking objective of pulp quality, economic objective, and SE consumption objective, the sequential quadratic programming method is utilized to produce the optimal predictive controllers. In conclusion, the simulation results demonstrate that the proposed methods can make the HC refining system provide a better performance of set-point tracking of pulp quality when these predictive controllers are employed. In addition, while the optimal predictive controllers orienting with comprehensive economic objective and SE consumption objective, it has been shown that they have significantly reduced the energy consumption.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Mingjie; Zhou, Ping; Wang, Hong
As one of the most important unit in the papermaking industry, the high consistency (HC) refining system is confronted with challenges such as improving pulp quality, energy saving, and emissions reduction in its operation processes. Here in this correspondence, an optimal operation of HC refining system is presented using nonlinear multiobjective model predictive control strategies that aim at set-point tracking objective of pulp quality, economic objective, and specific energy (SE) consumption objective, respectively. First, a set of input and output data at different times are employed to construct the subprocess model of the state process model for the HC refiningmore » system, and then the Wiener-type model can be obtained through combining the mechanism model of Canadian Standard Freeness and the state process model that determines their structures based on Akaike information criterion. Second, the multiobjective optimization strategy that optimizes both the set-point tracking objective of pulp quality and SE consumption is proposed simultaneously, which uses NSGA-II approach to obtain the Pareto optimal set. Furthermore, targeting at the set-point tracking objective of pulp quality, economic objective, and SE consumption objective, the sequential quadratic programming method is utilized to produce the optimal predictive controllers. In conclusion, the simulation results demonstrate that the proposed methods can make the HC refining system provide a better performance of set-point tracking of pulp quality when these predictive controllers are employed. In addition, while the optimal predictive controllers orienting with comprehensive economic objective and SE consumption objective, it has been shown that they have significantly reduced the energy consumption.« less
Improving Forecast Skill by Assimilation of Quality Controlled AIRS Version 5 Temperature Soundings
NASA Technical Reports Server (NTRS)
Susskind, Joel; Reale, Oreste
2009-01-01
The AIRS Science Team Version 5 retrieval algorithm has been finalized and is now operational at the Goddard DAAC in the processing (and reprocessing) of all AIRS data. The AIRS Science Team Version 5 retrieval algorithm contains two significant improvements over Version 4: 1) Improved physics allows for use of AIRS observations in the entire 4.3 micron CO2 absorption band in the retrieval of temperature profile T(p) during both day and night. Tropospheric sounding 15 micron CO2 observations are now used primarily in the generation of cloud cleared radiances R(sub i). This approach allows for the generation of accurate values of R(sub i) and T(p) under most cloud conditions. 2) Another very significant improvement in Version 5 is the ability to generate accurate case-by-case, level-by-level error estimates for the atmospheric temperature profile, as well as for channel-by-channel error estimates for R(sub i). These error estimates are used for Quality Control of the retrieved products. We have conducted forecast impact experiments assimilating AIRS temperature profiles with different levels of Quality Control using the NASA GEOS-5 data assimilation system. Assimilation of Quality Controlled T(p) resulted in significantly improved forecast skill compared to that obtained from analyses obtained when all data used operationally by NCEP, except for AIRS data, is assimilated. We also conducted an experiment assimilating AIRS radiances uncontaminated by clouds, as done operationally by ECMWF and NCEP. Forecast resulting from assimilated AIRS radiances were of poorer quality than those obtained assimilating AIRS temperatures.
Pharmaceutical quality by design: product and process development, understanding, and control.
Yu, Lawrence X
2008-04-01
The purpose of this paper is to discuss the pharmaceutical Quality by Design (QbD) and describe how it can be used to ensure pharmaceutical quality. The QbD was described and some of its elements identified. Process parameters and quality attributes were identified for each unit operation during manufacture of solid oral dosage forms. The use of QbD was contrasted with the evaluation of product quality by testing alone. The QbD is a systemic approach to pharmaceutical development. It means designing and developing formulations and manufacturing processes to ensure predefined product quality. Some of the QbD elements include: Defining target product quality profile; Designing product and manufacturing processes; Identifying critical quality attributes, process parameters, and sources of variability; Controlling manufacturing processes to produce consistent quality over time. Using QbD, pharmaceutical quality is assured by understanding and controlling formulation and manufacturing variables. Product testing confirms the product quality. Implementation of QbD will enable transformation of the chemistry, manufacturing, and controls (CMC) review of abbreviated new drug applications (ANDAs) into a science-based pharmaceutical quality assessment.
NASA Technical Reports Server (NTRS)
Perri, Todd A.; Mckillip, R. M., Jr.; Curtiss, H. C., Jr.
1987-01-01
The development and methodology is presented for development of full-authority implicit model-following and explicit model-following optimal controllers for use on helicopters operating in the Nap-of-the Earth (NOE) environment. Pole placement, input-output frequency response, and step input response were used to evaluate handling qualities performance. The pilot was equipped with velocity-command inputs. A mathematical/computational trajectory optimization method was employed to evaluate the ability of each controller to fly NOE maneuvers. The method determines the optimal swashplate and thruster input histories from the helicopter's dynamics and the prescribed geometry and desired flying qualities of the maneuver. Three maneuvers were investigated for both the implicit and explicit controllers with and without auxiliary propulsion installed: pop-up/dash/descent, bob-up at 40 knots, and glideslope. The explicit controller proved to be superior to the implicit controller in performance and ease of design.
25 CFR 216.4 - Technical examination of prospective surface exploration and mining operations.
Code of Federal Regulations, 2013 CFR
2013-04-01
... mining sites and mining operations vary widely with respect to topography, climate, surrounding land uses... quality below standards established by the appropriate State water pollution control agency, or by the...
25 CFR 216.4 - Technical examination of prospective surface exploration and mining operations.
Code of Federal Regulations, 2014 CFR
2014-04-01
... mining sites and mining operations vary widely with respect to topography, climate, surrounding land uses... quality below standards established by the appropriate State water pollution control agency, or by the...
25 CFR 216.4 - Technical examination of prospective surface exploration and mining operations.
Code of Federal Regulations, 2011 CFR
2011-04-01
... mining sites and mining operations vary widely with respect to topography, climate, surrounding land uses... quality below standards established by the appropriate State water pollution control agency, or by the...
25 CFR 216.4 - Technical examination of prospective surface exploration and mining operations.
Code of Federal Regulations, 2012 CFR
2012-04-01
... mining sites and mining operations vary widely with respect to topography, climate, surrounding land uses... quality below standards established by the appropriate State water pollution control agency, or by the...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-26
... Guidelines for Miscellaneous Metal and Plastic Parts Which Includes Pleasure Craft Coating Operations AGENCY... Miscellaneous Metal Parts and Plastic Coating (MMPPC) operations and as recommended by trade associations...
40 CFR 63.11221 - How do I monitor and collect data to demonstrate continuous compliance?
Code of Federal Regulations, 2012 CFR
2012-07-01
... malfunctions or out-of-control periods, or required monitoring system quality assurance or control activities... collect data according to this section. (b) You must operate the monitoring system and collect data at all required intervals at all times the affected source is operating except for periods of monitoring system...
40 CFR 63.11221 - How do I monitor and collect data to demonstrate continuous compliance?
Code of Federal Regulations, 2011 CFR
2011-07-01
... malfunctions or out-of-control periods, or required monitoring system quality assurance or control activities... collect data according to this section. (b) You must operate the monitoring system and collect data at all required intervals at all times the affected source is operating except for periods of monitoring system...
A new design to evaluate erosion and sediment control
Johnny M. Grace
2006-01-01
Water quality issues surrounding sediment movement related to forest operations are a focus in forest management. The forest road system is a primary area of concern related to sediment movement because roads are a component of most forest operations. Controlling sediment movement is a common objective in most forestry best management practices (BMPs). However, there...
Statewide implementation of Pave-IR in the Texas Department of Transportation.
DOT National Transportation Integrated Search
2012-02-01
This project conducted work to complement implementation of Pave-IR into the Texas Department of : Transportations hot-mix-asphalt quality control/quality assurance specification. Pave-IR provides real-time : thermal profiling of paving operations...
Poveda Gabaldón, Marta; Ovies, María Rosario; Orta Mira, Nieves; Serrano, M del Remedio Guna; Avila, Javier; Giménez, Alicia; Cardona, Concepción Gimeno
2011-12-01
The quality standard "UNE-EN-ISO 17043: 2010. Conformity assessment. General requirements for proficiency testing" applies to centers that organize intercomparisons in all areas. In the case of clinical microbiology laboratories, these intercomparisons must meet the management and technical standards required to achieve maximum quality in the performance of microbiological analysis and the preparation of test items (sample, product, data or other information used in the proficiency test) to enable them to be accredited. Once accredited, these laboratories can operate as a tool for quality control laboratories and competency assessment. In Spain, accreditation is granted by the Spanish Accreditation Body [Entidad Nacional de Acreditación (ENAC)]. The objective of this review is to explain how to apply the requirements of the standard to laboratories providing intercomparisons in the field of clinical microbiology (the organization responsible for all the tasks related to the development and operation of a proficiency testing program). This requires defining the scope and specifying the technical requirements (personnel management, control of equipment, facilities and environment, the design of the proficiency testing and data analysis for performance evaluation, communication with participants and confidentiality) and management requirements (document control, purchasing control, monitoring of complaints / claims, non-compliance, internal audits and management reviews). Copyright © 2011 Elsevier España S.L. All rights reserved.
40 CFR 63.10010 - What are my monitoring, installation, operation, and maintenance requirements?
Code of Federal Regulations, 2013 CFR
2013-07-01
... that emissions are controlled with a common control device or series of control devices, are discharged... parallel control devices or multiple series of control devices are discharged to the atmosphere through... quality control activities (including, as applicable, calibration checks and required zero and span...
40 CFR 63.10010 - What are my monitoring, installation, operation, and maintenance requirements?
Code of Federal Regulations, 2014 CFR
2014-07-01
... that emissions are controlled with a common control device or series of control devices, are discharged... parallel control devices or multiple series of control devices are discharged to the atmosphere through... quality control activities (including, as applicable, calibration checks and required zero and span...
ERIC Educational Resources Information Center
Montgomery, Thomas L.; And Others
1975-01-01
The technique of intermittent control systems for air quality control as developed and used by the Tennessee Valley Authority is investigated. Although controversial, all Tennessee Valley Authority sulfur dioxide elimination programs are scheduled to be operational this year. Existing or anticipated intermittent control systems are identified. (BT)
23 CFR 650.207 - Plans, specifications and estimates.
Code of Federal Regulations, 2010 CFR
2010-04-01
... OPERATIONS BRIDGES, STRUCTURES, AND HYDRAULICS Erosion and Sediment Control on Highway Construction Projects... highway project designs for the control of erosion and sedimentation and the protection of water quality...
23 CFR 650.207 - Plans, specifications and estimates.
Code of Federal Regulations, 2014 CFR
2014-04-01
... OPERATIONS BRIDGES, STRUCTURES, AND HYDRAULICS Erosion and Sediment Control on Highway Construction Projects... highway project designs for the control of erosion and sedimentation and the protection of water quality...
23 CFR 650.207 - Plans, specifications and estimates.
Code of Federal Regulations, 2013 CFR
2013-04-01
... OPERATIONS BRIDGES, STRUCTURES, AND HYDRAULICS Erosion and Sediment Control on Highway Construction Projects... highway project designs for the control of erosion and sedimentation and the protection of water quality...
23 CFR 650.207 - Plans, specifications and estimates.
Code of Federal Regulations, 2011 CFR
2011-04-01
... OPERATIONS BRIDGES, STRUCTURES, AND HYDRAULICS Erosion and Sediment Control on Highway Construction Projects... highway project designs for the control of erosion and sedimentation and the protection of water quality...
23 CFR 650.207 - Plans, specifications and estimates.
Code of Federal Regulations, 2012 CFR
2012-04-01
... OPERATIONS BRIDGES, STRUCTURES, AND HYDRAULICS Erosion and Sediment Control on Highway Construction Projects... highway project designs for the control of erosion and sedimentation and the protection of water quality...
Quality and Control of Water Vapor Winds
NASA Technical Reports Server (NTRS)
Jedlovec, Gary J.; Atkinson, Robert J.
1996-01-01
Water vapor imagery from the geostationary satellites such as GOES, Meteosat, and GMS provides synoptic views of dynamical events on a continual basis. Because the imagery represents a non-linear combination of mid- and upper-tropospheric thermodynamic parameters (three-dimensional variations in temperature and humidity), video loops of these image products provide enlightening views of regional flow fields, the movement of tropical and extratropical storm systems, the transfer of moisture between hemispheres and from the tropics to the mid- latitudes, and the dominance of high pressure systems over particular regions of the Earth. Despite the obvious larger scale features, the water vapor imagery contains significant image variability down to the single 8 km GOES pixel. These features can be quantitatively identified and tracked from one time to the next using various image processing techniques. Merrill et al. (1991), Hayden and Schmidt (1992), and Laurent (1993) have documented the operational procedures and capabilities of NOAA and ESOC to produce cloud and water vapor winds. These techniques employ standard correlation and template matching approaches to wind tracking and use qualitative and quantitative procedures to eliminate bad wind vectors from the wind data set. Techniques have also been developed to improve the quality of the operational winds though robust editing procedures (Hayden and Veldon 1991). These quality and control approaches have limitations, are often subjective, and constrain wind variability to be consistent with model derived wind fields. This paper describes research focused on the refinement of objective quality and control parameters for water vapor wind vector data sets. New quality and control measures are developed and employed to provide a more robust wind data set for climate analysis, data assimilation studies, as well as operational weather forecasting. The parameters are applicable to cloud-tracked winds as well with minor modifications. The improvement in winds through use of these new quality and control parameters is measured without the use of rawinsonde or modeled wind field data and compared with other approaches.
[Strategies and development of quality assurance and control in the ELSA-Brasil].
Schmidt, Maria Inês; Griep, Rosane Härter; Passos, Valéria Maria; Luft, Vivian Cristine; Goulart, Alessandra Carvalho; Menezes, Greice Maria de Souza; Molina, Maria del Carmen Bisi; Vigo, Alvaro; Nunes, Maria Angélica
2013-06-01
The ELSA-Brasil (Estudo Longitudinal de Saúde do Adulto - Brazilian Longitudinal Study for Adult Health) is a cohort study composed of 15,105 adults followed up in order to assess the development of chronic diseases, especially diabetes and cardiovascular disease. Its size, multicenter nature and the diversity of measurements required effective and efficient mechanisms of quality assurance and control. The main quality assurance activities (those developed before data collection) were: careful selection of research instruments, centralized training and certification, pretesting and pilot studies, and preparation of operation manuals for the procedures. Quality control activities (developed during data collection and processing) were performed more intensively at the beginning, when routines had not been established yet. The main quality control activities were: periodic observation of technicians, test-retest studies, data monitoring, network of supervisors, and cross visits. Data that estimate the reliability of the obtained information attest that the quality goals have been achieved.
Operative and nonoperative treatment of clavicle fractures in adults
2012-01-01
Background and purpose Traditionally, clavicle fractures have been treated nonoperatively. However, many recent studies have concentrated on the results of operative treatment. We assessed and compared the outcomes of operative and nonoperative treatment for acute clavicle fractures in adults. Methods We performed a systematic search of the medical literature from 1966 until the end of March 2011. We included randomized controlled trials and controlled clinical trials comparing operative and nonoperative treatment and studies comparing different operative and nonoperative treatments. We required that there should be at least 30 adult patients and a follow-up of at least 6 months in each individual trial. We used the GRADE method to assess the quality of evidence. Results 6 randomized controlled trials (n = 631) and 7 controlled clinical trials (n = 559) were included. There was moderate-quality evidence (i.e. of grade B) (1) that surgery has considerable effectiveness on better function and less disability at short follow-up, (2) of similar risk of relatively mild complications after operative or nonoperative treatment, (3) that delayed union and nonunion were more common in patients who were treated nonoperatively than in those treated operatively, and (4) that the osteosynthesis method had no effect on the incidence of delayed union or nonunion. Only 1 controlled clinical trial was found on lateral clavicle fractures with very limited (grade D) evidence. Interpretation Patients treated operatively have slightly better function and less disability than those treated nonoperatively at short follow-up, but then the effectiveness diminishes and is weak at 6 months. The different operative techniques may not differ in effectiveness or in adverse effects, but the evidence is very limited or conflicting. Surgery could be considered for active patients who require recovery to the previous level of activity in the shortest possible time. PMID:22248169
Lee, JuneHyuck; Noh, Sang Do; Kim, Hyun-Jung; Kang, Yong-Shin
2018-01-01
The prediction of internal defects of metal casting immediately after the casting process saves unnecessary time and money by reducing the amount of inputs into the next stage, such as the machining process, and enables flexible scheduling. Cyber-physical production systems (CPPS) perfectly fulfill the aforementioned requirements. This study deals with the implementation of CPPS in a real factory to predict the quality of metal casting and operation control. First, a CPPS architecture framework for quality prediction and operation control in metal-casting production was designed. The framework describes collaboration among internet of things (IoT), artificial intelligence, simulations, manufacturing execution systems, and advanced planning and scheduling systems. Subsequently, the implementation of the CPPS in actual plants is described. Temperature is a major factor that affects casting quality, and thus, temperature sensors and IoT communication devices were attached to casting machines. The well-known NoSQL database, HBase and the high-speed processing/analysis tool, Spark, are used for IoT repository and data pre-processing, respectively. Many machine learning algorithms such as decision tree, random forest, artificial neural network, and support vector machine were used for quality prediction and compared with R software. Finally, the operation of the entire system is demonstrated through a CPPS dashboard. In an era in which most CPPS-related studies are conducted on high-level abstract models, this study describes more specific architectural frameworks, use cases, usable software, and analytical methodologies. In addition, this study verifies the usefulness of CPPS by estimating quantitative effects. This is expected to contribute to the proliferation of CPPS in the industry. PMID:29734699
ITC Guidelines on Quality Control in Scoring, Test Analysis, and Reporting of Test Scores
ERIC Educational Resources Information Center
Allalouf, Avi
2014-01-01
The Quality Control (QC) Guidelines are intended to increase the efficiency, precision, and accuracy of the scoring, analysis, and reporting process of testing. The QC Guidelines focus on large-scale testing operations where multiple forms of tests are created for use on set dates. However, they may also be used for a wide variety of other testing…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-20
... the Operation of Outdoor Wood-Fired Boilers AGENCY: Environmental Protection Agency (EPA). ACTION... the operation of outdoor wood-fired boilers (OWBs). EPA is approving this revision to reduce particular matter emissions from the operation of outdoor wood-fired boilers in accordance with the...
Assimilation of Quality Controlled AIRS Temperature Profiles using the NCEP GFS
NASA Technical Reports Server (NTRS)
Susskind, Joel; Reale, Oreste; Iredell, Lena; Rosenberg, Robert
2013-01-01
We have previously conducted a number of data assimilation experiments using AIRS Version-5 quality controlled temperature profiles as a step toward finding an optimum balance of spatial coverage and sounding accuracy with regard to improving forecast skill. The data assimilation and forecast system we used was the Goddard Earth Observing System Model , Version-5 (GEOS-5) Data Assimilation System (DAS), which represents a combination of the NASA GEOS-5 forecast model with the National Centers for Environmental Prediction (NCEP) operational Grid Point Statistical Interpolation (GSI) global analysis scheme. All analyses and forecasts were run at a 0.5deg x 0.625deg spatial resolution. Data assimilation experiments were conducted in four different seasons, each in a different year. Three different sets of data assimilation experiments were run during each time period: Control; AIRS T(p); and AIRS Radiance. In the "Control" analysis, all the data used operationally by NCEP was assimilated, but no AIRS data was assimilated. Radiances from the Aqua AMSU-A instrument were also assimilated operationally by NCEP and are included in the "Control". The AIRS Radiance assimilation adds AIRS observed radiance observations for a select set of channels to the data set being assimilated, as done operationally by NCEP. In the AIRS T(p) assimilation, all information used in the Control was assimilated as well as Quality Controlled AIRS Version-5 temperature profiles, i.e., AIRS T(p) information was substituted for AIRS radiance information. The AIRS Version-5 temperature profiles were presented to the GSI analysis as rawinsonde profiles, assimilated down to a case-by-case appropriate pressure level p(sub best) determined using the Quality Control procedure. Version-5 also determines case-by-case, level-by-level error estimates of the temperature profiles, which were used as the uncertainty of each temperature measurement. These experiments using GEOS-5 have shown that forecasts resulting from analyses using the AIRS T(p) assimilation system were superior to those from the Radiance assimilation system, both with regard to global 7 day forecast skill and also the ability to predict storm tracks and intensity.
Total Quality Management (TQM), an Overview
1991-09-01
Quality Management (TQM). It discusses the reasons TQM is a current growth industry, what it is, and how one implements it. It describes the basic analytical tools, statistical process control, some advanced analytical tools, tools used by process improvement teams to enhance their own operations, and action plans for making improvements. The final sections discuss assessing quality efforts and measuring the quality to knowledge
Unlocking Flexibility: Integrated Optimization and Control of Multienergy Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dall'Anese, Emiliano; Mancarella, Pierluigi; Monti, Antonello
Electricity, natural gas, water, and dis trict heating/cooling systems are predominantly planned and operated independently. However, it is increasingly recognized that integrated optimization and control of such systems at multiple spatiotemporal scales can bring significant socioeconomic, operational efficiency, and environmental benefits. Accordingly, the concept of the multi-energy system is gaining considerable attention, with the overarching objectives of 1) uncovering fundamental gains (and potential drawbacks) that emerge from the integrated operation of multiple systems and 2) developing holistic yet computationally affordable optimization and control methods that maximize operational benefits, while 3) acknowledging intrinsic interdependencies and quality-of-service requirements for each provider.
1983-01-01
RAI-RI247443 LARGE-SCALE OPERATIONS MANAGEMENT TEST OF USE OF THE i/i UNITE AMUR FOR CONTR.. (U) MILLER RND MILLER INC ORLANDO FL H D MILLER ET RL...LARGE-SCALE OPERATIONS MANAGEMENT TEST OF USE OF THE WHITE AMUR FOR CONTROL OF PROBLEM AQUATIC PLANTS Report 1: Baseline Studies Volume I...Boyd, J. 1983. "Large-Scale Operations Management Test of Use of the White Amur for Control of Problem Aquatic Plants; Report 4, Third Year Poststocking
A Risk Management Architecture for Emergency Integrated Aircraft Control
NASA Technical Reports Server (NTRS)
McGlynn, Gregory E.; Litt, Jonathan S.; Lemon, Kimberly A.; Csank, Jeffrey T.
2011-01-01
Enhanced engine operation--operation that is beyond normal limits--has the potential to improve the adaptability and safety of aircraft in emergency situations. Intelligent use of enhanced engine operation to improve the handling qualities of the aircraft requires sophisticated risk estimation techniques and a risk management system that spans the flight and propulsion controllers. In this paper, an architecture that weighs the risks of the emergency and of possible engine performance enhancements to reduce overall risk to the aircraft is described. Two examples of emergency situations are presented to demonstrate the interaction between the flight and propulsion controllers to facilitate the enhanced operation.
Enhancing water quality in hydropower system operations
NASA Astrophysics Data System (ADS)
Hayes, Donald F.; Labadie, John W.; Sanders, Thomas G.; Brown, Jackson K.
1998-03-01
The quality of impounded waters often degrades over time because of thermal stratification, sediment oxygen demands, and accumulation of pollutants. Consequently, reservoir releases impact water quality in tailwaters, channels, and other downstream water bodies. Low dissolved oxygen (DO) concentrations in the Cumberland River below Old Hickory dam result from stratification of upstream reservoirs and seasonally low release rates. Operational changes in upstream hydropower reservoirs may be one method to increase DO levels without substantially impacting existing project purposes. A water quality model of the upper Cumberland basin is integrated into an optimal control algorithm to evaluate water quality improvement opportunities through operational modifications. The integrated water quantity/quality model maximizes hydropower revenues, subject to various flow and headwater operational restrictions for satisfying multiple project purposes, as well as maintenance of water quality targets. Optimal daily reservoir release policies are determined for the summer drawdown period which increase DO concentrations under stratification conditions with minimal impact on hydropower production and other project purposes. Appendixes A-D available with entire article on microfiche. Order by mail from AGU, 2000 Florida Ave., N.W., Washington, DC 20009 or by phone at 800-966-2481; $2.50. Document W97-003. Payment must accompany order.
Influence of water quality on the embodied energy of drinking water treatment.
Santana, Mark V E; Zhang, Qiong; Mihelcic, James R
2014-01-01
Urban water treatment plants rely on energy intensive processes to provide safe, reliable water to users. Changes in influent water quality may alter the operation of a water treatment plant and its associated energy use or embodied energy. Therefore the objective of this study is to estimate the effect of influent water quality on the operational embodied energy of drinking water, using the city of Tampa, Florida as a case study. Water quality and water treatment data were obtained from the David L Tippin Water Treatment Facility (Tippin WTF). Life cycle energy analysis (LCEA) was conducted to calculate treatment chemical embodied energy values. Statistical methods including Pearson's correlation, linear regression, and relative importance were used to determine the influence of water quality on treatment plant operation and subsequently, embodied energy. Results showed that influent water quality was responsible for about 14.5% of the total operational embodied energy, mainly due to changes in treatment chemical dosages. The method used in this study can be applied to other urban drinking water contexts to determine if drinking water source quality control or modification of treatment processes will significantly minimize drinking water treatment embodied energy.
NASA Astrophysics Data System (ADS)
Sabanin, V. R.; Starostin, A. A.; Repin, A. I.; Popov, A. I.
2017-02-01
The problems of operation effectiveness increase of steam boilers are considered. To maintain the optimum fuel combustion modes, it is proposed to use an extremal controller (EC) determining the value of airflow rate, at which the boiler generating the desired amount of heat will consume a minimum amount of fuel. EC sets the determined value of airflow rate to airflow rate controller (ARC). The test results of numerical simulation dynamic nonlinear model of steam boiler with the connected system of automatic control of load and combustion efficiency using EC are presented. The model is created in the Simulink modeling package of MATLAB software and can be used to optimize the combustion modes. Based on the modeling results, the conclusion was drawn about the possibility in principle of simultaneously boiler load control and optimizing by EC the combustion modes when changing the fuel combustion heat and the boiler characteristics and its operating mode. It is shown that it is possible to automatically control the operation efficiency of steam boilers when using EC without applying the standard flue gas analyzers. The article considers the numerical simulation dynamic model of steam boiler with the schemes of control of fuel consumption and airflow rate, the steam pressure and EC; the purpose of using EC in the scheme with linear controllers and the requirements to the quality of its operation; the results of operation of boiler control schemes without EC with estimation of influence of roughness of thermal mode maps on the nature of static and dynamic connection of the control units of fuel consumption and airflow rate; the phase trajectories and the diagrams of transient processes occurring in the control scheme with EC with stepped changing the fuel quality and boiler characteristics; analysis of modeling results and prospects for using EC in the control schemes of boilers.
USDA-ARS?s Scientific Manuscript database
Research, operational, and commercial programs which rely on mass-reared insects of high quality and performance, need accurate methods for monitoring quality degradation during each step of production, handling and release. With continued interest in the use of the sterile insect technique (SIT) a...
Software Quality Assurance and Controls Standard
2010-04-27
Software Quality Assurance d C t l St d dan on ro s an ar Sue Carroll Principal Software Quality Analyst, SAS John Wal z VP Technology and...for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington VA 22202-4302. Respondents should be aware that...Cycle (SLC) process? • What is in a SQA Process? • Where are SQA Controls? • What is the SQA standards history? Wh t i h i i SQA?• a s c ang ng n
NASA. Langley Research Center dry powder towpreg system
NASA Technical Reports Server (NTRS)
Baucom, Robert M.; Marchello, Joseph M.
1990-01-01
Dry powder polymer impregnated carbon fiber tows were produced for preform weaving and composite materials molding applications. In the process, fluidized powder is deposited on spread tow bundles and melted on the fibers by radiant heating to adhere the polymer to the fiber. Unit design theory and operating correlations were developed to provide the basis for scale up of the process to commercial operation. Special features of the operation are the pneumatic tow spreader, fluidized bed, resin feeder, and quality control system. Bench scale experiments, at tow speeds up to 50 cm/sec, demonstrated that process variables can be controlled to produce weavable LARC-TPI carbon fiber towpreg. The towpreg made by the dry powder process was formed into unidirectional fiber moldings and was woven and molded into preform material of good quality.
Strategies of performance self-monitoring in automotive production.
Faye, Hélène; Falzon, Pierre
2009-09-01
Production in the automotive industry, based on assembly line work, is now characterized by lean manufacturing and customization. This results in greater flexibility and increased quality demands, including worker performance self-monitoring. The objectives of this study are to refine the concept of performance self-monitoring and to characterize the strategies developed by operators to achieve it. Data were collected based on the method of individual auto-confrontation, consisting of two steps: eleven assembly-line operators of a French automotive company were individually observed and video-taped while they were working; an interview then allowed each operator to discuss his/her activity based on the video-tape. This study expands the concept of performance self-monitoring by highlighting three types of strategies directly oriented toward quality: prevention, feedback control and control action strategies.
Manufacturing Execution Systems: Examples of Performance Indicator and Operational Robustness Tools.
Gendre, Yannick; Waridel, Gérard; Guyon, Myrtille; Demuth, Jean-François; Guelpa, Hervé; Humbert, Thierry
Manufacturing Execution Systems (MES) are computerized systems used to measure production performance in terms of productivity, yield, and quality. In the first part, performance indicator and overall equipment effectiveness (OEE), process robustness tools and statistical process control are described. The second part details some tools to help process robustness and control by operators by preventing deviations from target control charts. MES was developed by Syngenta together with CIMO for automation.
NASA Astrophysics Data System (ADS)
Pries, V. V.; Proskuriakov, N. E.
2018-04-01
To control the assembly quality of multi-element mass-produced products on automatic rotor lines, control methods with operational feedback are required. However, due to possible failures in the operation of the devices and systems of automatic rotor line, there is always a real probability of getting defective (incomplete) products into the output process stream. Therefore, a continuous sampling control of the products completeness, based on the use of statistical methods, remains an important element in managing the quality of assembly of multi-element mass products on automatic rotor lines. The feature of continuous sampling control of the multi-element products completeness in the assembly process is its breaking sort, which excludes the possibility of returning component parts after sampling control to the process stream and leads to a decrease in the actual productivity of the assembly equipment. Therefore, the use of statistical procedures for continuous sampling control of the multi-element products completeness when assembled on automatic rotor lines requires the use of such sampling plans that ensure a minimum size of control samples. Comparison of the values of the limit of the average output defect level for the continuous sampling plan (CSP) and for the automated continuous sampling plan (ACSP) shows the possibility of providing lower limit values for the average output defects level using the ACSP-1. Also, the average sample size when using the ACSP-1 plan is less than when using the CSP-1 plan. Thus, the application of statistical methods in the assembly quality management of multi-element products on automatic rotor lines, involving the use of proposed plans and methods for continuous selective control, will allow to automating sampling control procedures and the required level of quality of assembled products while minimizing sample size.
Xu, Shi-Zhou; Wang, Chun-Jie; Lin, Fang-Li; Li, Shi-Xiang
2017-10-31
The multi-device open-circuit fault is a common fault of ANPC (Active Neutral-Point Clamped) three-level inverter and effect the operation stability of the whole system. To improve the operation stability, this paper summarized the main solutions currently firstly and analyzed all the possible states of multi-device open-circuit fault. Secondly, an order-reduction optimal control strategy was proposed under multi-device open-circuit fault to realize fault-tolerant control based on the topology and control requirement of ANPC three-level inverter and operation stability. This control strategy can solve the faults with different operation states, and can works in order-reduction state under specific open-circuit faults with specific combined devices, which sacrifices the control quality to obtain the stability priority control. Finally, the simulation and experiment proved the effectiveness of the proposed strategy.
Advanced helicopter cockpit and control configurations for helicopter combat missions
NASA Technical Reports Server (NTRS)
Haworth, Loran A.; Atencio, Adolph, Jr.; Bivens, Courtland; Shively, Robert; Delgado, Daniel
1987-01-01
Two piloted simulations were conducted by the U.S. Army Aeroflightdynamics Directorate to evaluate workload and helicopter-handling qualities requirements for single pilot operation in a combat Nap-of-the-Earth environment. The single-pilot advanced cockpit engineering simulation (SPACES) investigations were performed on the NASA Ames Vertical Motion Simulator, using the Advanced Digital Optical Control System control laws and an advanced concepts glass cockpit. The first simulation (SPACES I) compared single pilot to dual crewmember operation for the same flight tasks to determine differences between dual and single ratings, and to discover which control laws enabled adequate single-pilot helicopter operation. The SPACES II simulation concentrated on single-pilot operations and use of control laws thought to be viable candidates for single pilot operations workload. Measures detected significant differences between single-pilot task segments. Control system configurations were task dependent, demonstrating a need for inflight reconfigurable control system to match the optimal control system with the required task.
SPOT satellite family: Past, present, and future of the operations in the mission and control center
NASA Technical Reports Server (NTRS)
Philippe, Pacholczyk
1993-01-01
SPOT sun-synchronous remote sensing satellites are operated by CNES since February 1986. Today, the SPOT mission and control center (CCM) operates SPOT1, SPOT2, and is ready to operate SPOT3. During these seven years, the way to operate changed and the CCM, initially designed for the control of one satellite, has been modified and upgraded to support these new operating modes. All these events have shown the performances and the limits of the system. A new generation of satellite (SPOT4) will continue the remote sensing mission during the second half of the 90's. Its design takes into account the experience of the first generation and supports several improvements. A new generation of control center (CMP) has been developed and improves the efficiency, quality, and reliability of the operations. The CMP is designed for operating two satellites at the same time during launching, in-orbit testing, and operating phases. It supports several automatic procedures and improves data retrieval and reporting.
Honing process optimization algorithms
NASA Astrophysics Data System (ADS)
Kadyrov, Ramil R.; Charikov, Pavel N.; Pryanichnikova, Valeria V.
2018-03-01
This article considers the relevance of honing processes for creating high-quality mechanical engineering products. The features of the honing process are revealed and such important concepts as the task for optimization of honing operations, the optimal structure of the honing working cycles, stepped and stepless honing cycles, simulation of processing and its purpose are emphasized. It is noted that the reliability of the mathematical model determines the quality parameters of the honing process control. An algorithm for continuous control of the honing process is proposed. The process model reliably describes the machining of a workpiece in a sufficiently wide area and can be used to operate the CNC machine CC743.
Operational Processing of Ground Validation Data for the Tropical Rainfall Measuring Mission
NASA Technical Reports Server (NTRS)
Kulie, Mark S.; Robinson, Mike; Marks, David A.; Ferrier, Brad S.; Rosenfeld, Danny; Wolff, David B.
1999-01-01
The Tropical Rainfall Measuring Mission (TRMM) satellite was successfully launched in November 1997. A primary goal of TRMM is to sample tropical rainfall using the first active spaceborne precipitation radar. To validate TRMM satellite observations, a comprehensive Ground Validation (GV) Program has been implemented for this mission. A key component of GV is the analysis and quality control of meteorological ground-based radar data from four primary sites: Melbourne, FL; Houston, TX; Darwin, Australia; and Kwajalein Atoll, RMI. As part of the TRMM GV effort, the Joint Center for Earth Systems Technology (JCET) at the University of Maryland, Baltimore County, has been tasked with developing and implementing an operational system to quality control (QC), archive, and provide data for subsequent rainfall product generation from the four primary GV sites. This paper provides an overview of the JCET operational environment. A description of the QC algorithm and performance, in addition to the data flow procedure between JCET and the TRNM science and Data Information System (TSDIS), are presented. The impact of quality-controlled data on higher level rainfall and reflectivity products will also be addressed, Finally, a brief description of JCET's expanded role into producing reference rainfall products will be discussed.
Apperception of Clouds in AIRS Data
NASA Technical Reports Server (NTRS)
Huang, Hung-Lung; Smith, William L.
2005-01-01
Our capacity to simulate the radiative characteristics of the Earth system has advanced greatly over the past decade. However, new space based measurements show that idealized simulations might not adequately represent the complexity of nature. For example, AIRS simulated multi-layer cloud clearing research provides an excellent groundwork for early Atmospheric Infra-Red Sounder (AIRS) operational cloud clearing and atmospheric profile retrieval. However, it doesn't reflect the complicated reality of clouds over land and coastal areas. Thus far, operational AIRS/AMSU (Advanced Microwave Sounding Unit) cloud clearing is not only of low yield but also of unsatisfying quality. This is not an argument for avoiding this challenging task, rather a powerful argument for exploring other synergistic approaches, and for adapting these strategies toward improving both indirect and direct use of cloudy infrared sounding data. Ample evidence is shown in this paper that the indirect use of cloudy sounding data by way of cloud clearing is sub-optimal for data assimilation. Improvements are needed in quality control, retrieval yield, and overall cloud clearing retrieval performance. For example, cloud clearing over land, especially over the desert surface, has led to much degraded retrieval quality and often a very low yield of quality controlled cloud cleared radiances. If these indirect cloud cleared radiances are instead to be directly assimilated into NWP models, great caution must be used. Our limited and preliminary cloud clearing results from AIRS/AMSU (with the use of MODIS data) and an AIRS/MODIS synergistic approach have, however, shown that higher spatial resolution multispectral imagery data can provide much needed quality control of the AIRS/AMSU cloud clearing retrieval. When AIRS and Moderate Resolution Imaging Spectroradiometer (MODIS) are used synergistically, a higher spatial resolution over difficult terrain (especially desert areas) can be achieved and with a much improved accuracy. Preliminary statistical analyses of cloud cleared radiances derived from (1) operational AIRS/AMSU, (2) operational AIRS/AMSU plus the use of MODIS data as quality control, and (3) AIRS/MODIS synergistic single channel and two field of views cloud clearing are Our capacity to simulate the radiative characteristics of the Earth system has
This document explains how to generate data which characterizes the performance of hazardous waste treatment systems in terms of the composition of treated hazardous waste streams plus treatment system operation and design.
Using the scanning electron microscope on the production line to assure quality semiconductors
NASA Technical Reports Server (NTRS)
Adolphsen, J. W.; Anstead, R. J.
1972-01-01
The use of the scanning electron microscope to detect metallization defects introduced during batch processing of semiconductor devices is discussed. A method of determining metallization integrity was developed which culminates in a procurement specification using the scanning microscope on the production line as a quality control tool. Batch process control of the metallization operation is monitored early in the manufacturing cycle.
Low-speed longitudinal orbiter qualities
NASA Technical Reports Server (NTRS)
Powers, B. G.
1985-01-01
The shuttle program took on the challenge of providing a manual landing capability for an operational vehicle returning from orbit. Some complex challenges were encountered in developing the longitudinal flying qualities required to land the orbiter manually in an operational environment. Approach and landing test flights indicated a tendency for pilot-induced oscillation near landing. Changes in the operational procedures reduced the difficulty of the landing task, and an adaptive stick filter was incorporated to reduce the severity of any pilot-induced oscillatory motions. Fixed-base, movingbase, and in-flight simulations were used for the evaluations, and in general, flight simulation was the only reliable means of assessing the low-speed longitudinal flying qualities problems. Overall, the orbiter control system and operational procedures have produced a good capability to routinely perform precise landings with a large, unpowered vehicle with a low lift-to-drag ratio.
(abstract) Mission Operations and Control Assurance: Flight Operations Quality Improvements
NASA Technical Reports Server (NTRS)
Welz, Linda L.; Bruno, Kristin J.; Kazz, Sheri L.; Witkowski, Mona M.
1993-01-01
Mission Operations and Command Assurance (MO&CA), a recent addition to flight operations teams at JPL. provides a system level function to instill quality in mission operations. MO&CA's primary goal at JPL is to help improve the operational reliability for projects during flight. MO&CA tasks include early detection and correction of process design and procedural deficiencies within projects. Early detection and correction are essential during development of operational procedures and training of operational teams. MO&CA's effort focuses directly on reducing the probability of radiating incorrect commands to a spacecraft. Over the last seven years at JPL, MO&CA has become a valuable asset to JPL flight projects. JPL flight projects have benefited significantly from MO&CA's efforts to contain risk and prevent rather than rework errors. MO&CA's ability to provide direct transfer of knowledge allows new projects to benefit directly from previous and ongoing experience. Since MO&CA, like Total Quality Management (TQM), focuses on continuous improvement of processes and elimination of rework, we recommend that this effort be continued on NASA flight projects.
Optimization of operator and physical parameters for laser welding of dental materials.
Bertrand, C; le Petitcorps, Y; Albingre, L; Dupuis, V
2004-04-10
Interactions between lasers and materials are very complex phenomena. The success of laser welding procedures in dental metals depends on the operator's control of many parameters. The aims of this study were to evaluate factors relating to the operator's dexterity and the choice of the welding parameters (power, pulse duration and therefore energy), which are recognized determinants of weld quality. In vitro laboratory study. FeNiCr dental drawn wires were chosen for these experiments because their properties are well known. Different diameters of wires were laser welded, then tested in tension and compared to the control material as extruded, in order to evaluate the quality of the welding. Scanning electron microscopy of the fractured zone and micrograph observations perpendicular and parallel to the wire axis were also conducted in order to analyse the depth penetration and the quality of the microstructure. Additionally, the micro-hardness (Vickers type) was measured both in the welded and the heat-affected zones and then compared to the non-welded alloy. Adequate combination of energy and pulse duration with the power set in the range between 0.8 to 1 kW appears to improve penetration depth of the laser beam and success of the welding procedure. Operator skill is also an important variable. The variation in laser weld quality in dental FeNiCr wires attributable to operator skill can be minimized by optimization of the physical welding parameters.
Saturn S-2 quality assurance techniques, critical process control. Volume 7: Metallic materials
NASA Technical Reports Server (NTRS)
Ross, W. D., Jr.
1970-01-01
The special skills developed during the Saturn S-2 Program are documented to enable qualified personnel to carry out efficient operations in future S-2 production. Skills covered include: acceptance testing of fusion-welding equipment, weld operators and inspector certification, machine certification, preweld operations, and repair weld certification.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-15
... the Operation of Outdoor Wood-Fired Boilers AGENCY: Environmental Protection Agency (EPA). ACTION... from the operation of outdoor wood-fired boilers. This action is being taken under the Clean Air Act... the operation of outdoor wood-fired boilers (OWBs). I. Background On July 18, 1997 (62 FR 38652), EPA...
Data Assimilation Experiments using Quality Controlled AIRS Version 5 Temperature Soundings
NASA Technical Reports Server (NTRS)
Susskind, Joel
2008-01-01
The AIRS Science Team Version 5 retrieval algorithm has been finalized and is now operational at the Goddard DAAC in the processing (and reprocessing) of all AlRS data. Version 5 contains accurate case-by-case error estimates for most derived products, which are also used for quality control. We have conducted forecast impact experiments assimilating AlRS quality controlled temperature profiles using the NASA GEOS-5 data assimilation system, consisting of the NCEP GSI analysis coupled with the NASA FVGCM. Assimilation of quality controlled temperature profiles resulted in significantly improved forecast skill in both the Northern Hemisphere and Southern Hemisphere Extra-Tropics, compared to that obtained from analyses obtained when all data used operationally by NCEP except for AlRS data is assimilated. Experiments using different Quality Control thresholds for assimilation of AlRS temperature retrievals showed that a medium quality control threshold performed better than a tighter threshold, which provided better overall sounding accuracy; or a looser threshold, which provided better spatial coverage of accepted soundings. We are conducting more experiments to further optimize this balance of spatial coverage and sounding accuracy from the data assimilation perspective. In all cases, temperature soundings were assimilated well below cloud level in partially cloudy cases. The positive impact of assimilating AlRS derived atmospheric temperatures all but vanished when only AIRS stratospheric temperatures were assimilated. Forecast skill resulting from assimilation of AlRS radiances uncontaminated by clouds, instead of AlRS temperature soundings, was only slightly better than that resulting from assimilation of only stratospheric AlRS temperatures. This reduction in forecast skill is most likely the result of significant loss of tropospheric information when only AIRS radiances unaffected by clouds are used in the data assimilation process.
Hunt, Andrew G.
2015-08-12
This report addresses the standard operating procedures used by the U.S. Geological Survey’s Noble Gas Laboratory in Denver, Colorado, U.S.A., for the measurement of dissolved gases (methane, nitrogen, oxygen, and carbon dioxide) and noble gas isotopes (helium-3, helium-4, neon-20, neon-21, neon-22, argon-36, argon-38, argon-40, kryton-84, krypton-86, xenon-103, and xenon-132) dissolved in water. A synopsis of the instrumentation used, procedures followed, calibration practices, standards used, and a quality assurance and quality control program is presented. The report outlines the day-to-day operation of the Residual Gas Analyzer Model 200, Mass Analyzer Products Model 215–50, and ultralow vacuum extraction line along with the sample handling procedures, noble gas extraction and purification, instrument measurement procedures, instrumental data acquisition, and calculations for the conversion of raw data from the mass spectrometer into noble gas concentrations per unit mass of water analyzed. Techniques for the preparation of artificial dissolved gas standards are detailed and coupled to a quality assurance and quality control program to present the accuracy of the procedures used in the laboratory.
Hartman, Victoria; Castillo-Pelayo, Tania; Babinszky, Sindy; Dee, Simon; Leblanc, Jodi; Matzke, Lise; O'Donoghue, Sheila; Carpenter, Jane; Carter, Candace; Rush, Amanda; Byrne, Jennifer; Barnes, Rebecca; Mes-Messons, Anne-Marie; Watson, Peter
2018-02-01
Ongoing quality management is an essential part of biobank operations and the creation of high quality biospecimen resources. Adhering to the standards of a national biobanking network is a way to reduce variability between individual biobank processes, resulting in cross biobank compatibility and more consistent support for health researchers. The Canadian Tissue Repository Network (CTRNet) implemented a set of required operational practices (ROPs) in 2011 and these serve as the standards and basis for the CTRNet biobank certification program. A review of these 13 ROPs covering 314 directives was conducted after 5 years to identify areas for revision and update, leading to changes to 7/314 directives (2.3%). A review of all internal controlled documents (including policies, standard operating procedures and guides, and forms for actions and processes) used by the BC Cancer Agency's Tumor Tissue Repository (BCCA-TTR) to conform to these ROPs was then conducted. Changes were made to 20/106 (19%) of BCCA-TTR documents. We conclude that a substantial fraction of internal controlled documents require updates at regular intervals to accommodate changes in best practices. Reviewing documentation is an essential aspect of keeping up to date with best practices and ensuring the quality of biospecimens and data managed by biobanks.
Validation of a proposal for evaluating hospital infection control programs.
Silva, Cristiane Pavanello Rodrigues; Lacerda, Rúbia Aparecida
2011-02-01
To validate the construct and discriminant properties of a hospital infection prevention and control program. The program consisted of four indicators: technical-operational structure; operational prevention and control guidelines; epidemiological surveillance system; and prevention and control activities. These indicators, with previously validated content, were applied to 50 healthcare institutions in the city of São Paulo, Southeastern Brazil, in 2009. Descriptive statistics were used to characterize the hospitals and indicator scores, and Cronbach's α coefficient was used to evaluate the internal consistency. The discriminant validity was analyzed by comparing indicator scores between groups of hospitals: with versus without quality certification. The construct validity analysis was based on exploratory factor analysis with a tetrachoric correlation matrix. The indicators for the technical-operational structure and epidemiological surveillance presented almost 100% conformity in the whole sample. The indicators for the operational prevention and control guidelines and the prevention and control activities presented internal consistency ranging from 0.67 to 0.80. The discriminant validity of these indicators indicated higher and statistically significant mean conformity scores among the group of institutions with healthcare certification or accreditation processes. In the construct validation, two dimensions were identified for the operational prevention and control guidelines: recommendations for preventing hospital infection and recommendations for standardizing prophylaxis procedures, with good correlation between the analysis units that formed the guidelines. The same was found for the prevention and control activities: interfaces with treatment units and support units were identified. Validation of the measurement properties of the hospital infection prevention and control program indicators made it possible to develop a tool for evaluating these programs in an ethical and scientific manner in order to obtain a quality diagnosis in this field.
Laha, Arpita; Ghosh, Sarmila; Das, Haripada
2012-01-01
Background: Addition of clonidine to ropivacaine (0.2%) can potentially enhance analgesia without producing prolonged motor blockade. The aim of the present study was to compare the post-operative pain relieving quality of ropivacaine 0.2% and clonidine mixture to that of plain ropivacaine 0.2% following caudal administration in children. Methods: In a prospective, double-blinded, randomized controlled trial, 30 ASA 1 pediatric patients undergoing infraumbilical surgery were randomly allocated to receive a caudal injection of either plain ropivacaine 0.2% (1 ml/kg) (group A) or a mixture of ropivacaine 0.2% (1 ml/kg) with clonidine 2 μg/kg (group B). Objective pain score and need for supplemental analgesics were compared during the 1st 24 hours postoperatively. Residual post-operative sedation and motor blockade were also assessed. Results: Significantly prolonged duration of post-operative analgesia was observed in group B (P<0.0001). Heart rate and blood pressure were not different in 2 groups. Neither motor blockade nor post-operative sedation varied significantly between the groups. Conclusion: The combination of clonidine (2 μg/kg) and ropivacaine 0.2% was associated with an improved quality of post-operative analgesia compared to plain 0.2% ropivacaine. The improved analgesic quality of the clonidine-ropivacaine mixture was achieved without causing any significant degree of post-operative sedation or prolongation of motor blockade. PMID:23162389
NASA Technical Reports Server (NTRS)
Bailey, Randall E.; Jackson, E. Bruce; Goodrich, Kenneth H.; Ragsdale, W. Al; Neuhaus, Jason; Barnes, Jim
2008-01-01
A program of research, development, test, and evaluation is planned for the development of Spacecraft Handling Qualities guidelines. In this first experiment, the effects of Reaction Control System design characteristics and rotational control laws were evaluated during simulated proximity operations and docking. Also, the influence of piloting demands resulting from varying closure rates was assessed. The pilot-in-the-loop simulation results showed that significantly different spacecraft handling qualities result from the design of the Reaction Control System. In particular, cross-coupling between translational and rotational motions significantly affected handling qualities as reflected by Cooper-Harper pilot ratings and pilot workload, as reflected by Task-Load Index ratings. This influence is masked but only slightly by the rotational control system mode. While rotational control augmentation using Rate Command Attitude Hold can reduce the workload (principally, physical workload) created by cross-coupling, the handling qualities are not significantly improved. The attitude and rate deadbands of the RCAH introduced significant mental workload and control compensation to evaluate when deadband firings would occur, assess their impact on docking performance, and apply control inputs to mitigate that impact.
Real-time product attribute control to manufacture antibodies with defined N-linked glycan levels.
Zupke, Craig; Brady, Lowell J; Slade, Peter G; Clark, Philip; Caspary, R Guy; Livingston, Brittney; Taylor, Lisa; Bigham, Kyle; Morris, Arvia E; Bailey, Robert W
2015-01-01
Pressures for cost-effective new therapies and an increased emphasis on emerging markets require technological advancements and a flexible future manufacturing network for the production of biologic medicines. The safety and efficacy of a product is crucial, and consistent product quality is an essential feature of any therapeutic manufacturing process. The active control of product quality in a typical biologic process is challenging because of measurement lags and nonlinearities present in the system. The current study uses nonlinear model predictive control to maintain a critical product quality attribute at a predetermined value during pilot scale manufacturing operations. This approach to product quality control ensures a more consistent product for patients, enables greater manufacturing efficiency, and eliminates the need for extensive process characterization by providing direct measures of critical product quality attributes for real time release of drug product. © 2015 American Institute of Chemical Engineers.
Cairo consensus on the IVF laboratory environment and air quality: report of an expert meeting.
Mortimer, D; Cohen, J; Mortimer, S T; Fawzy, M; McCulloh, D H; Morbeck, D E; Pollet-Villard, X; Mansour, R T; Brison, D R; Doshi, A; Harper, J C; Swain, J E; Gilligan, A V
2018-03-02
This proceedings report presents the outcomes from an international Expert Meeting to establish a consensus on the recommended technical and operational requirements for air quality within modern assisted reproduction technology (ART) laboratories. Topics considered included design and construction of the facility, as well as its heating, ventilation and air conditioning system; control of particulates, micro-organisms (bacteria, fungi and viruses) and volatile organic compounds (VOCs) within critical areas; safe cleaning practices; operational practices to optimize air quality while minimizing physicochemical risks to gametes and embryos (temperature control versus air flow); and appropriate infection-control practices that minimize exposure to VOC. More than 50 consensus points were established under the general headings of assessing site suitability, basic design criteria for new construction, and laboratory commissioning and ongoing VOC management. These consensus points should be considered as aspirational benchmarks for existing ART laboratories, and as guidelines for the construction of new ART laboratories. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
Piloting Vertical Flight Aircraft: A Conference on Flying Qualities and Human Factors
NASA Technical Reports Server (NTRS)
Blanken, Christopher L. (Editor); Whalley, Matthew S. (Editor)
1993-01-01
This document contains papers from a specialists' meeting entitled 'Piloting Vertical Flight Aircraft: A Conference on Flying Qualities and Human Factors.' Vertical flight aircraft, including helicopters and a variety of Vertical Takeoff and Landing (VTOL) concepts, place unique requirements on human perception, control, and performance for the conduct of their design missions. The intent of this conference was to examine, for these vehicles, advances in: (1) design of flight control systems for ADS-33C standards; (2) assessment of human factors influences of cockpit displays and operational procedures; (3) development of VTOL design and operational criteria; and (4) development of theoretical methods or models for predicting pilot/vehicle performance and mission suitability. A secondary goal of the conference was to provide an initial venue for enhanced interaction between human factors and handling qualities specialists.
Knowledge acquisition for a simple expert controller
NASA Technical Reports Server (NTRS)
Bieker, B.
1987-01-01
A method is presented for process control which has the properties of being incremental, cyclic and top-down. It is described on the basis of the development of an expert controller for a simple, but nonlinear control route. A quality comparison between expert controller and process operator shows the ability of the method for knowledge acquisition.
An engineering approach to controlling indoor air quality.
Woods, J E
1991-11-01
Evidence is accumulating that indicates air quality problems in residential and commercial buildings are nearly always associated with inadequacies in building design and methods of operation. Thus, the very systems depended on to control the indoor environment can become indirect sources of contamination if diligence is not exercised at each stage of a building's life: a) planning and design, b) construction and commissioning, c) operation, and d) demolition or renovation. In this paper, an engineering perspective is presented in which the existing building stock is characterized in terms of its environmental performance. Preliminary data indicate that 20 to 30% of the existing buildings have sufficient problems to manifest as sick-building syndrome or building-related illness, while another 10 to 20% may have undetected problems. Thus, only about 50 to 70% of the existing buildings qualify as healthy buildings. Two methods and three mechanisms of control are described to achieve "acceptable" indoor air quality: source control and exposure control. If sources cannot be removed, some level of occupant exposure will result. To control exposures with acceptable values, the primary sensory receptors of the occupants (i.e., thermal, ocular, auditory, and olfactory) cannot be excessively stimulated. The three exposure control mechanisms are conduction, radiation, and convection. To achieve acceptable occupant responses, it is often practical to integrate the mechanisms of radiation and convection in heating, ventilating, and air conditioning systems that are designed to provide acceptable thermal, acoustic, and air quality conditions within occupied spaces.(ABSTRACT TRUNCATED AT 250 WORDS)
An engineering approach to controlling indoor air quality.
Woods, J E
1991-01-01
Evidence is accumulating that indicates air quality problems in residential and commercial buildings are nearly always associated with inadequacies in building design and methods of operation. Thus, the very systems depended on to control the indoor environment can become indirect sources of contamination if diligence is not exercised at each stage of a building's life: a) planning and design, b) construction and commissioning, c) operation, and d) demolition or renovation. In this paper, an engineering perspective is presented in which the existing building stock is characterized in terms of its environmental performance. Preliminary data indicate that 20 to 30% of the existing buildings have sufficient problems to manifest as sick-building syndrome or building-related illness, while another 10 to 20% may have undetected problems. Thus, only about 50 to 70% of the existing buildings qualify as healthy buildings. Two methods and three mechanisms of control are described to achieve "acceptable" indoor air quality: source control and exposure control. If sources cannot be removed, some level of occupant exposure will result. To control exposures with acceptable values, the primary sensory receptors of the occupants (i.e., thermal, ocular, auditory, and olfactory) cannot be excessively stimulated. The three exposure control mechanisms are conduction, radiation, and convection. To achieve acceptable occupant responses, it is often practical to integrate the mechanisms of radiation and convection in heating, ventilating, and air conditioning systems that are designed to provide acceptable thermal, acoustic, and air quality conditions within occupied spaces.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:1821369
Automatic Control of the Concrete Mixture Homogeneity in Cycling Mixers
NASA Astrophysics Data System (ADS)
Anatoly Fedorovich, Tikhonov; Drozdov, Anatoly
2018-03-01
The article describes the factors affecting the concrete mixture quality related to the moisture content of aggregates, since the effectiveness of the concrete mixture production is largely determined by the availability of quality management tools at all stages of the technological process. It is established that the unaccounted moisture of aggregates adversely affects the concrete mixture homogeneity and, accordingly, the strength of building structures. A new control method and the automatic control system of the concrete mixture homogeneity in the technological process of mixing components have been proposed, since the tasks of providing a concrete mixture are performed by the automatic control system of processing kneading-and-mixing machinery with operational automatic control of homogeneity. Theoretical underpinnings of the control of the mixture homogeneity are presented, which are related to a change in the frequency of vibrodynamic vibrations of the mixer body. The structure of the technical means of the automatic control system for regulating the supply of water is determined depending on the change in the concrete mixture homogeneity during the continuous mixing of components. The following technical means for establishing automatic control have been chosen: vibro-acoustic sensors, remote terminal units, electropneumatic control actuators, etc. To identify the quality indicator of automatic control, the system offers a structure flowchart with transfer functions that determine the ACS operation in transient dynamic mode.
Paver automation for road surfacing
NASA Astrophysics Data System (ADS)
Tihonov, A.; Velichkin, V.
2017-10-01
The paper discusses factors that bear on the quality of motor road pavement as access roads and highways are built and used. A block diagram is proposed to organize elements of the automatic control system to control the asphalt paver’s mechanisms; the system is based on a microprocessor onboard controller to maintain preset elevation of the finishing plate; description of its operation principle is offered. The paper names primary converters to control the finishing plate elevation. A new control method is described to control the machine’s straight-line movement with GLONASS Satellite Positioning System (SPS) during operation.
Maximum entropy approach to fuzzy control
NASA Technical Reports Server (NTRS)
Ramer, Arthur; Kreinovich, Vladik YA.
1992-01-01
For the same expert knowledge, if one uses different &- and V-operations in a fuzzy control methodology, one ends up with different control strategies. Each choice of these operations restricts the set of possible control strategies. Since a wrong choice can lead to a low quality control, it is reasonable to try to loose as few possibilities as possible. This idea is formalized and it is shown that it leads to the choice of min(a + b,1) for V and min(a,b) for &. This choice was tried on NASA Shuttle simulator; it leads to a maximally stable control.
NASA Technical Reports Server (NTRS)
Jamar, L. G.
1986-01-01
Quality and innovation are the hallmarks of the national space program. In programs that preceded the Shuttle Program the emphasis was on meeting the risks and technical challenges of space with safety, quality, reliability, and success. At United Technologies Aerospace Operations, Inc. (UTAO), the battle has developed along four primary fronts. These fronts include programs to motivate and reward people, development and construction of optimized processes and facilities, implementation of specifically tailored management systems, and the application of appropriate measurement and control systems. Each of these initiatives is described. However, to put this quality and productivity program in perspective, UTAO and its role in the Shuttle Program are described first.
SPOT4 Operational Control Center (CMP)
NASA Technical Reports Server (NTRS)
Zaouche, G.
1993-01-01
CNES(F) is responsible for the development of a new generation of Operational Control Center (CMP) which will operate the new heliosynchronous remote sensing satellite (SPOT4). This Operational Control Center takes large benefit from the experience of the first generation of control center and from the recent advances in computer technology and standards. The CMP is designed for operating two satellites all the same time with a reduced pool of controllers. The architecture of this CMP is simple, robust, and flexible, since it is based on powerful distributed workstations interconnected through an Ethernet LAN. The application software uses modern and formal software engineering methods, in order to improve quality and reliability, and facilitate maintenance. This software is table driven so it can be easily adapted to other operational needs. Operation tasks are automated to the maximum extent, so that it could be possible to operate the CMP automatically with very limited human interference for supervision and decision making. This paper provides an overview of the SPOTS mission and associated ground segment. It also details the CMP, its functions, and its software and hardware architecture.
Bobkov, Iu G; Epishkin, A K
1988-01-01
This paper presents experimental findings indicating that bemithyl, an actoprotective agent, has a beneficial effect on the health status and work capacity of operators during simulated space flight and 56-hour continuous work. The drug enhanced psychophysiological tolerance of the operators and improved the quality of their work: the quality of their compensatory tracking was on the average 10% higher, the number of errors of their porsuit tracking was 1.8 times lower, and the time of visual signal detection was 2.4 times shorter as compared to the placebo controls.
Quality-assurance plan for water-resources activities of the U.S. Geological Survey in Idaho
Packard, F.A.
1996-01-01
To ensure continued confidence in its products, the Water Resources Division of the U.S. Geological Survey implemented a policy that all its scientific work be performed in accordance with a centrally managed quality-assurance program. This report establishes and documents a formal policy for current (1995) quality assurance within the Idaho District of the U.S. Geological Survey. Quality assurance is formalized by describing district organization and operational responsibilities, documenting the district quality-assurance policies, and describing district functions. The districts conducts its work through offices in Boise, Idaho Falls, Twin Falls, Sandpoint, and at the Idaho National Engineering Laboratory. Data-collection programs and interpretive studies are conducted by two operating units, and operational and technical assistance is provided by three support units: (1) Administrative Services advisors provide guidance on various personnel issues and budget functions, (2) computer and reports advisors provide guidance in their fields, and (3) discipline specialists provide technical advice and assistance to the district and to chiefs of various projects. The district's quality-assurance plan is based on an overall policy that provides a framework for defining the precision and accuracy of collected data. The plan is supported by a series of quality-assurance policy statements that describe responsibilities for specific operations in the district's program. The operations are program planning; project planning; project implementation; review and remediation; data collection; equipment calibration and maintenance; data processing and storage; data analysis, synthesis, and interpretation; report preparation and processing; and training. Activities of the district are systematically conducted under a hierarchy of supervision an management that is designed to ensure conformance with Water Resources Division goals quality assurance. The district quality-assurance plan does not describe detailed technical activities that are commonly termed "quality-control procedures." Instead, it focuses on current policies, operations, and responsibilities that are implemented at the management level. Contents of the plan will be reviewed annually and updated as programs and operations change.
Some Inspection Methods for Quality Control and In-service Inspection of GLARE
NASA Astrophysics Data System (ADS)
Sinke, J.
2003-07-01
Quality control of materials and structures is an important issue, also for GLARE. During the manufacturing stage the processes and materials should be monitored and checked frequently in order to obtain a qualified product. During the operation of the aircraft, frequent monitoring and inspections are performed to maintain the quality at a prescribed level. Therefore, in-service inspection methods are applied, and when necessary repair activities are conducted. For the quality control of the GLARE panels and components during manufacturing, the C-scan method proves to be an effective tool. For in-service inspection the Eddy Current Method is one of the suitable options. In this paper a brief overview is presented of both methods and their application on GLARE products.
[The impact of preoperative stoma siting and stoma care education on patient's quality of life].
Gulbiniene, Jurgita; Markelis, Rytis; Tamelis, Algimantas; Saladzinskas, Zilvinas
2004-01-01
The aim of study was to assess if preoperative stoma selection and adequate patient's teaching can affect the postoperative patient's quality of life. The study was performed in two university hospitals of Lithuania: Kaunas University of Medicine Hospital and Kaunas Oncology Hospital. Patients were divided into three groups. Patients were asked to answer the questionnaire the day before the stoma creation operation and two months after the operation. Questionnaires EORTC QLQ-C30, EORTC QLQ-CR38 and 10 supplementary questions were used. The results of the study show that following the stoma operation, when compared with preoperative results, general quality of life did not change significantly in groups I and II. Patients who received adequate education and preoperative stoma siting had better emotional functioning and less gastrointestinal problems. The financial problems of the patients in group I were significantly less than in the control group. Patients who received the adequate teaching without preoperative stoma selection experience better sexual satisfaction compared with control group. Stoma related problems were less in group I and II when comparing with the control group. The quality of the patients' teaching, adequacy and comfort of stoma site and satisfaction with the medical staff were significantly better in the group I and group II when compared to control group. Moreover, these results were significantly higher in the group I than in group II. CONCLUSIONS. The teaching the patients preoperatively and postoperative proceeding helps them to gain better experience in self stoma care hence reducing the psychological, physical, emotional, social and sexual problems.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-06
... curing ovens used in wet-laid non-woven fiber mat manufacturing operations when nitrogen containing resins or other additives are used. These two actions affect NO X sources operating in the Dallas Fort...
Managing Vocabulary Mapping Services
Che, Chengjian; Monson, Kent; Poon, Kasey B.; Shakib, Shaun C.; Lau, Lee Min
2005-01-01
The efficient management and maintenance of large-scale and high-quality vocabulary mapping is an operational challenge. The 3M Health Information Systems (HIS) Healthcare Data Dictionary (HDD) group developed an information management system to provide controlled mapping services, resulting in improved efficiency and quality maintenance. PMID:16779203
12 CFR 652.60 - Corporation board guidelines.
Code of Federal Regulations, 2010 CFR
2010-01-01
.... (a) Your board of directors is responsible for ensuring that you maintain total capital at a level... developing the capital adequacy plan: (1) Capability of management; (2) Strategies and objectives in your business plan; (3) Quality of operating policies, procedures, and internal controls; (4) Quality and...
Nuclear Technology Series. Course 7: Reactor Operations.
ERIC Educational Resources Information Center
Center for Occupational Research and Development, Inc., Waco, TX.
This technical specialty course is one of thirty-five courses designed for use by two-year postsecondary institutions in five nuclear technician curriculum areas: (1) radiation protection technician, (2) nuclear instrumentation and control technician, (3) nuclear materials processing technician, (4) nuclear quality-assurance/quality-control…
The report defines a simplified methodology that can be used by indoor air quality (IAQ) diagnosticians, architects/engineers, building owners/operators, and the scientific community for preliminary comparison of the cost-effectiveness of alternative IAQ control measures for any ...
Comprehensive Testing Guidelines to Increase Efficiency in INDOT Operations : [Technical Summary
DOT National Transportation Integrated Search
2012-01-01
When the Indiana Department of Transportation designs a pavement project, a decision for QC/QA (Quality Control/ Quality Assurance) or nonQC/QA is made solely based on the quantity of pavement materials to be used in the project. Once the pavement...
Comprehensive Testing Guidelines to Increase Efficiency in INDOT Operations : [Technical Summary
DOT National Transportation Integrated Search
2012-01-01
When the Indiana Department of Transportation designs : a pavement project, a decision for QC/QA (Quality Control/ : Quality Assurance) or nonQC/QA is made solely : based on the quantity of pavement materials to be used : in the project. Once the ...
12 CFR 652.60 - Corporation board guidelines.
Code of Federal Regulations, 2011 CFR
2011-01-01
.... (a) Your board of directors is responsible for ensuring that you maintain total capital at a level... developing the capital adequacy plan: (1) Capability of management; (2) Strategies and objectives in your business plan; (3) Quality of operating policies, procedures, and internal controls; (4) Quality and...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aegerter, P.A.
Phillips Petroleum Company scientists and engineers have been operating petroleum refining and separations pilot plants for five years in the Process Development Center. The 26 pilot plants in this building, with one exception, operate under complete computer-control, allowing maximum utilization of limited operating manpower. This centralization and automation of pilot plants has allowed Phillips to more than double the number of operating pilot plants in the petroleum refining area without an increase in manpower. At the same time, the quantity and quality of data has increased correspondingly. This paper discusses Phillips philosophy of operation and management of these pilot plants.more » In addition, details of day-to-day operations and a brief description of the control system are also presented.« less
Anthony, T. Renée; Altmaier, Ralph; Park, Jae Hong; Peters, Thomas M.
2016-01-01
Because adverse health effects experienced by swine farm workers in concentrated animal feeding operations (CAFOs) have been associated with exposure to dust and gases, efforts to reduce exposures are warranted, particularly in winter seasons when exposures increase due to decreased ventilation. Simulation of air quality and operating costs for ventilating swine CAFO, including treating and recirculating air through a farrowing room, was performed using mass and energy balance equations over a 90-day winter season. System operation required controlling heater operation to achieve room temperatures optimal to ensure animal health (20 to 22.5°C). Five air pollution control devices, four room ventilation rates, and five recirculation patterns were examined. Inhalable dust concentrations were easily reduced using standard industrial air pollution control devices, including a cyclone, filtration, and electrostatic precipitator. Operating ventilation systems at 0.94 m3 s−1 (2000 cfm) with 75 to 100% recirculation of treated air from cyclone, electrostatic precipitator, and shaker dust filtration system achieves adequate particle control with operating costs under $1.00 per pig produced ($0.22 to 0.54), although carbon dioxide (CO2) concentrations approach 2000 ppm using in-room ventilated gas fired heaters. In no simulation were CO2 concentrations below industry recommended concentrations (1540 ppm), but alternative heating devices could reduce CO2 to acceptable concentrations. While this investigation does not represent all production swine farrowing barns, which differ in characteristics including room dimensions and swine occupancy, the simulation model and ventilation optimization methods can be applied to other production sites. This work shows that ventilation may be a cost-effective control option in the swine industry to reduce exposures. PMID:24433305
Anthony, T Renée; Altmaier, Ralph; Park, Jae Hong; Peters, Thomas M
2014-01-01
Because adverse health effects experienced by swine farm workers in concentrated animal feeding operations (CAFOs) have been associated with exposure to dust and gases, efforts to reduce exposures are warranted, particularly in winter seasons when exposures increase due to decreased ventilation. Simulation of air quality and operating costs for ventilating swine CAFO, including treating and recirculating air through a farrowing room, was performed using mass and energy balance equations over a 90-day winter season. System operation required controlling heater operation to achieve room temperatures optimal to ensure animal health (20 to 22.5 °C). Five air pollution control devices, four room ventilation rates, and five recirculation patterns were examined. Inhalable dust concentrations were easily reduced using standard industrial air pollution control devices, including a cyclone, filtration, and electrostatic precipitator. Operating ventilation systems at 0.94 m3 s(-1) (2000 cfm) with 75 to 100% recirculation of treated air from cyclone, electrostatic precipitator, and shaker dust filtration system achieves adequate particle control with operating costs under $1.00 per pig produced ($0.22 to 0.54), although carbon dioxide (CO2) concentrations approach 2000 ppm using in-room ventilated gas fired heaters. In no simulation were CO2 concentrations below industry recommended concentrations (1540 ppm), but alternative heating devices could reduce CO2 to acceptable concentrations. While this investigation does not represent all production swine farrowing barns, which differ in characteristics including room dimensions and swine occupancy, the simulation model and ventilation optimization methods can be applied to other production sites. This work shows that ventilation may be a cost-effective control option in the swine industry to reduce exposures.
Synthesis of the unmanned aerial vehicle remote control augmentation system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tomczyk, Andrzej, E-mail: A.Tomczyk@prz.edu.pl
Medium size Unmanned Aerial Vehicle (UAV) usually flies as an autonomous aircraft including automatic take-off and landing phases. However in the case of the on-board control system failure, the remote steering is using as an emergency procedure. In this reason, remote manual control of unmanned aerial vehicle is used more often during take-of and landing phases. Depends on UAV take-off mass and speed (total energy) the potential crash can be very danger for airplane and environment. So, handling qualities of UAV is important from pilot-operator point of view. In many cases the dynamic properties of remote controlling UAV are notmore » suitable for obtaining the desired properties of the handling qualities. In this case the control augmentation system (CAS) should be applied. Because the potential failure of the on-board control system, the better solution is that the CAS algorithms are placed on the ground station computers. The method of UAV handling qualities shaping in the case of basic control system failure is presented in this paper. The main idea of this method is that UAV reaction on the operator steering signals should be similar - almost the same - as reaction of the 'ideal' remote control aircraft. The model following method was used for controller parameters calculations. The numerical example concerns the medium size MP-02A UAV applied as an aerial observer system.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rauch, Phillip; Lin, Pei-Jan Paul; Balter, Stephen
2012-05-15
Task Group 125 (TG 125) was charged with investigating the functionality of fluoroscopic automatic dose rate and image quality control logic in modern angiographic systems, paying specific attention to the spectral shaping filters and variations in the selected radiologic imaging parameters. The task group was also charged with describing the operational aspects of the imaging equipment for the purpose of assisting the clinical medical physicist with clinical set-up and performance evaluation. Although there are clear distinctions between the fluoroscopic operation of an angiographic system and its acquisition modes (digital cine, digital angiography, digital subtraction angiography, etc.), the scope of thismore » work was limited to the fluoroscopic operation of the systems studied. The use of spectral shaping filters in cardiovascular and interventional angiography equipment has been shown to reduce patient dose. If the imaging control algorithm were programmed to work in conjunction with the selected spectral filter, and if the generator parameters were optimized for the selected filter, then image quality could also be improved. Although assessment of image quality was not included as part of this report, it was recognized that for fluoroscopic imaging the parameters that influence radiation output, differential absorption, and patient dose are also the same parameters that influence image quality. Therefore, this report will utilize the terminology ''automatic dose rate and image quality'' (ADRIQ) when describing the control logic in modern interventional angiographic systems and, where relevant, will describe the influence of controlled parameters on the subsequent image quality. A total of 22 angiography units were investigated by the task group and of these one each was chosen as representative of the equipment manufactured by GE Healthcare, Philips Medical Systems, Shimadzu Medical USA, and Siemens Medical Systems. All equipment, for which measurement data were included in this report, was manufactured within the three year period from 2006 to 2008. Using polymethylmethacrylate (PMMA) plastic to simulate patient attenuation, each angiographic imaging system was evaluated by recording the following parameters: tube potential in units of kilovolts peak (kVp), tube current in units of milliamperes (mA), pulse width (PW) in units of milliseconds (ms), spectral filtration setting, and patient air kerma rate (PAKR) as a function of the attenuator thickness. Data were graphically plotted to reveal the manner in which the ADRIQ control logic responded to changes in object attenuation. There were similarities in the manner in which the ADRIQ control logic operated that allowed the four chosen devices to be divided into two groups, with two of the systems in each group. There were also unique approaches to the ADRIQ control logic that were associated with some of the systems, and these are described in the report. The evaluation revealed relevant information about the testing procedure and also about the manner in which different manufacturers approach the utilization of spectral filtration, pulsed fluoroscopy, and maximum PAKR limitation. This information should be particularly valuable to the clinical medical physicist charged with acceptance testing and performance evaluation of modern angiographic systems.« less
Rauch, Phillip; Lin, Pei-Jan Paul; Balter, Stephen; Fukuda, Atsushi; Goode, Allen; Hartwell, Gary; LaFrance, Terry; Nickoloff, Edward; Shepard, Jeff; Strauss, Keith
2012-05-01
Task Group 125 (TG 125) was charged with investigating the functionality of fluoroscopic automatic dose rate and image quality control logic in modern angiographic systems, paying specific attention to the spectral shaping filters and variations in the selected radiologic imaging parameters. The task group was also charged with describing the operational aspects of the imaging equipment for the purpose of assisting the clinical medical physicist with clinical set-up and performance evaluation. Although there are clear distinctions between the fluoroscopic operation of an angiographic system and its acquisition modes (digital cine, digital angiography, digital subtraction angiography, etc.), the scope of this work was limited to the fluoroscopic operation of the systems studied. The use of spectral shaping filters in cardiovascular and interventional angiography equipment has been shown to reduce patient dose. If the imaging control algorithm were programmed to work in conjunction with the selected spectral filter, and if the generator parameters were optimized for the selected filter, then image quality could also be improved. Although assessment of image quality was not included as part of this report, it was recognized that for fluoroscopic imaging the parameters that influence radiation output, differential absorption, and patient dose are also the same parameters that influence image quality. Therefore, this report will utilize the terminology "automatic dose rate and image quality" (ADRIQ) when describing the control logic in modern interventional angiographic systems and, where relevant, will describe the influence of controlled parameters on the subsequent image quality. A total of 22 angiography units were investigated by the task group and of these one each was chosen as representative of the equipment manufactured by GE Healthcare, Philips Medical Systems, Shimadzu Medical USA, and Siemens Medical Systems. All equipment, for which measurement data were included in this report, was manufactured within the three year period from 2006 to 2008. Using polymethylmethacrylate (PMMA) plastic to simulate patient attenuation, each angiographic imaging system was evaluated by recording the following parameters: tube potential in units of kilovolts peak (kVp), tube current in units of milliamperes (mA), pulse width (PW) in units of milliseconds (ms), spectral filtration setting, and patient air kerma rate (PAKR) as a function of the attenuator thickness. Data were graphically plotted to reveal the manner in which the ADRIQ control logic responded to changes in object attenuation. There were similarities in the manner in which the ADRIQ control logic operated that allowed the four chosen devices to be divided into two groups, with two of the systems in each group. There were also unique approaches to the ADRIQ control logic that were associated with some of the systems, and these are described in the report. The evaluation revealed relevant information about the testing procedure and also about the manner in which different manufacturers approach the utilization of spectral filtration, pulsed fluoroscopy, and maximum PAKR limitation. This information should be particularly valuable to the clinical medical physicist charged with acceptance testing and performance evaluation of modern angiographic systems.
Janik, Michał Robert; Rogula, Tomasz; Bielecka, Ilona; Kwiatkowski, Andrzej; Paśnik, Krzysztof
2016-12-01
The aims of our study were to compare quality of life (QOL) in obese patients after bariatric surgery with that in controls seeking surgery and to investigate which factors are associated with QOL in the Moorehead-Ardelt Quality of Life Questionnaire II (MA II). This was a cross-sectional study. The operated group consisted of patients after laparoscopic sleeve gastrectomy or laparoscopic Roux-en-Y gastric bypass. The MA II was administered by e-mail to 305 patients 12-18 months after surgery. The control groups consisted of 101 obese patients. We compared the QOL scores and considered good and very good outcomes to be satisfactory. Multiple logistic regression and correlation analysis was performed to identify factors associated with QOL. In the operated group, the total MA II score was 1.70 ± 0.76, which was higher than 0.59 ± 1.17 in the control group. The score adjusted for the type of surgery was comparable. The prevalence of satisfactory QOL outcomes was similar in both post-operative subgroups and was still higher than in the control group. We identified four factors associated with higher QOL in obese patients. Weight loss was not correlated with total score in MAII. This study demonstrates that patients after bariatric surgery have a higher score in MA II, which reflects better QOL. The scoring adjusted by type of operation is comparable. QOL among obese patients is dependent on age, gender, history of bariatric surgery, and partnered status. Body mass reduction was not associated with outcome in MAII.
Raggi, Alessandra; Sanna, Tiziana; Mazzetti, Magda; Orsi, Alessandra; Zanni, Angela; Farruggia, Patrizia
2017-01-01
The microbiological contamination of operating theatres and the lack of adherence to best practices by surgical staff represent some of the factors affecting Surgical Site Infections (SSIs). The aim of the present study was to assess the microbiological quality of operating settings and the staff compliance to the SSI evidence-based control measures. Ten operating rooms were examined for microbiological contamination of air and surfaces, after cleaning procedures, in “at rest” conditions. Furthermore, 10 surgical operations were monitored to assess staff compliance to the recommended practices. None of the air samples exceeded microbiological reference standards and only six of the 200 surface samples (3.0%) were slightly above recommended levels. Potentially pathogenic bacteria and moulds were never detected. Staff compliance to best practices varied depending on the type of behaviour investigated and the role of the operator. The major not compliant behaviours were: pre-operative skin antisepsis, crowding of the operating room and hand hygiene of the anaesthetist. The good environmental microbiological quality observed is indicative of the efficacy of the cleaning-sanitization procedures adopted. The major critical point was staff compliance to recommended practices. Awareness campaigns are therefore necessary, aimed at improving the organisation of work so as to facilitate compliance to operative protocols. PMID:29283367
Knobel, LeRoy L.; Tucker, Betty J.; Rousseau, Joseph P.
2008-01-01
Water-quality activities conducted by the staff of the U.S. Geological Survey (USGS) Idaho National Laboratory (INL) Project Office coincide with the USGS mission of appraising the quantity and quality of the Nation's water resources. The activities are conducted in cooperation with the U.S. Department of Energy's (DOE) Idaho Operations Office. Results of the water-quality investigations are presented in various USGS publications or in refereed scientific journals. The results of the studies are highly regarded, and they are used with confidence by researchers, regulatory and managerial agencies, and interested civic groups. In its broadest sense, quality assurance refers to doing the job right the first time. It includes the functions of planning for products, review and acceptance of the products, and an audit designed to evaluate the system that produces the products. Quality control and quality assurance differ in that quality control ensures that things are done correctly given the 'state-of-the-art' technology, and quality assurance ensures that quality control is maintained within specified limits.
Goals and strategies in the global control design of the OAJ Robotic Observatory
NASA Astrophysics Data System (ADS)
Yanes-Díaz, A.; Rueda-Teruel, S.; Antón, J. L.; Rueda-Teruel, F.; Moles, M.; Cenarro, A. J.; Marín-Franch, A.; Ederoclite, A.; Gruel, N.; Varela, J.; Cristóbal-Hornillos, D.; Chueca, S.; Díaz-Martín, M. C.; Guillén, L.; Luis-Simoes, R.; Maícas, N.; Lamadrid, J. L.; López-Sainz, A.; Hernández-Fuertes, J.; Valdivielso, L.; Mendes de Oliveira, C.; Penteado, P.; Schoenell, W.; Kanaan, A.
2012-09-01
There are many ways to solve the challenging problem of making a high performance robotic observatory from scratch. The Observatorio Astrofísico de Javalambre (OAJ) is a new astronomical facility located in the Sierra de Javalambre (Teruel, Spain) whose primary role will be to conduct all-sky astronomical surveys. The OAJ control system has been designed from a global point of view including astronomical subsystems as well as infrastructures and other facilities. Three main factors have been considered in the design of a global control system for the robotic OAJ: quality, reliability and efficiency. We propose CIA (Control Integrated Architecture) design and OEE (Overall Equipment Effectiveness) as a key performance indicator in order to improve operation processes, minimizing resources and obtaining high cost reduction whilst maintaining quality requirements. The OAJ subsystems considered for the control integrated architecture are the following: two wide-field telescopes and their instrumentation, active optics subsystems, facilities for sky quality monitoring (seeing, extinction, sky background, sky brightness, cloud distribution, meteorological station), domes and several infrastructure facilities such as water supply, glycol water, water treatment plant, air conditioning, compressed air, LN2 plant, illumination, surveillance, access control, fire suppression, electrical generators, electrical distribution, electrical consumption, communication network, Uninterruptible Power Supply and two main control rooms, one at the OAJ and the other remotely located in Teruel, 40km from the observatory, connected through a microwave radio-link. This paper presents the OAJ strategy in control design to achieve maximum quality efficiency for the observatory processes and operations, giving practical examples of our approach.
Miyakoshi, N; Hongo, M; Kobayashi, T; Abe, T; Abe, E; Shimada, Y
2015-11-01
This study evaluated changes in spinal alignment and quality of life (QOL) after corrective spinal surgery for patients with postmenopausal osteoporosis and spinal kyphosis. Spinal global alignment and QOL were significantly improved after corrective spinal surgery but did not reach the level of non-operated controls. With the increased aging of society, the demand for corrective spinal instrumentation for spinal kyphosis in osteoporotic patients is increasing. However, previous studies have not focused on the improvement of quality of life (QOL) after corrective spinal surgery in patients with osteoporosis, compared to non-operated control patients. The purposes of this study were thus to evaluate changes in spinal alignment and QOL after corrective spinal instrumentation for patients with osteoporosis and spinal kyphosis and to compare these results with non-operated patients. Participants comprised 39 patients with postmenopausal osteoporosis ≥50 years old who underwent corrective spinal surgery using multilevel posterior lumbar interbody fusion (PLIF) for symptomatic thoracolumbar or lumbar kyphosis, and 82 age-matched patients with postmenopausal osteoporosis without prevalent vertebral fractures. Spinopelvic parameters were evaluated with standing lateral spine radiography, and QOL was evaluated with the Japanese Osteoporosis QOL Questionnaire (JOQOL), SF-36, and Roland-Morris Disability Questionnaire (RDQ). Lumbar kyphosis angle, sagittal vertical axis, and pelvic tilt were significantly improved postoperatively. QOL evaluated with all three questionnaires also significantly improved after 6 months postoperatively, particularly in domain and subscale scores for pain and general/mental health. However, these radiographic parameters, total JOQOL score, SF-36 physical component summary score, and RDQ score were significantly inferior compared with non-operated controls. The results indicate that spinal global alignment and QOL were significantly improved after corrective spinal surgery using multilevel PLIF for patients with osteoporosis and spinal kyphosis but did not reach the level of non-operated controls.
Twelfth Annual Conference on Manual Control
NASA Technical Reports Server (NTRS)
Wempe, T. E.
1976-01-01
Main topics discussed cover multi-task decision making, attention allocation and workload measurement, displays and controls, nonvisual displays, tracking and other psychomotor tasks, automobile driving, handling qualities and pilot ratings, remote manipulation, system identification, control models, and motion and visual cues. Sixty-five papers are included with presentations on results of analytical studies to develop and evaluate human operator models for a range of control task, vehicle dynamics and display situations; results of tests of physiological control systems and applications to medical problems; and on results of simulator and flight tests to determine display, control and dynamics effects on operator performance and workload for aircraft, automobile, and remote control systems.
2007-06-15
13 2.1.3 Quality of Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 2.2 Related Efforts...objectives such as resource management, Quality of Service (QoS), security, or access control. The limitations of CN applications should come from the...achieving the best mode of operation in an SDR. 2.1.3 Quality of Service There has been a lot of research on how to define a QoS architecture for the
NASA Technical Reports Server (NTRS)
Frost, Chad R.; Franklin, James A.; Hardy, Gordon H.
2002-01-01
A piloted simulation was performed on the Vertical Motion Simulator at NASA Ames Research Center to evaluate flying qualities of a tilt-wing Short Take-Off and Landing (STOL) transport aircraft during final approach and landing. The experiment was conducted to assess the design s handling qualities, and to evaluate the use of flightpath-centered guidance for the precision approach and landing tasks required to perform STOL operations in instrument meteorological conditions, turbulence, and wind. Pilots rated the handling qualities to be satisfactory for all operations evaluated except those encountering extreme crosswinds and severe windshear; even in these difficult meteorological conditions, adequate handling qualities were maintained. The advanced flight control laws and guidance displays provided consistent performance and precision landings.
Pianigiani, Elisa; Ierardi, Francesca; Fimiani, Michele
2013-12-01
Skin allografts represent an important therapeutic resource in the treatment of severe skin loss. The risk associated with application of processed tissues in humans is very low, however, human material always carries the risk of disease transmission. To minimise the risk of contamination of grafts, processing is carried out in clean rooms where air quality is monitored. Procedures and quality control tests are performed to standardise the production process and to guarantee the final product for human use. Since we only validate and distribute aseptic tissues, we conducted a study to determine what type of quality controls for skin processing are the most suitable for detecting processing errors and intercurrent contamination, and for faithfully mapping the process without unduly increasing production costs. Two different methods for quality control were statistically compared using the Fisher exact test. On the basis of the current study we selected our quality control procedure based on pre- and post-processing tissue controls, operator and environmental controls. Evaluation of the predictability of our control methods showed that tissue control was the most reliable method of revealing microbial contamination of grafts. We obtained 100 % sensitivity by doubling tissue controls, while maintaining high specificity (77 %).
Energy and water quality management systems for water utility's operations: a review.
Cherchi, Carla; Badruzzaman, Mohammad; Oppenheimer, Joan; Bros, Christopher M; Jacangelo, Joseph G
2015-04-15
Holistic management of water and energy resources is critical for water utilities facing increasing energy prices, water supply shortage and stringent regulatory requirements. In the early 1990s, the concept of an integrated Energy and Water Quality Management System (EWQMS) was developed as an operational optimization framework for solving water quality, water supply and energy management problems simultaneously. Approximately twenty water utilities have implemented an EWQMS by interfacing commercial or in-house software optimization programs with existing control systems. For utilities with an installed EWQMS, operating cost savings of 8-15% have been reported due to higher use of cheaper tariff periods and better operating efficiencies, resulting in the reduction in energy consumption of ∼6-9%. This review provides the current state-of-knowledge on EWQMS typical structural features and operational strategies and benefits and drawbacks are analyzed. The review also highlights the challenges encountered during installation and implementation of EWQMS and identifies the knowledge gaps that should motivate new research efforts. Copyright © 2015 Elsevier Ltd. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-19
... was part of Ohio's SIP, was rescinded by Ohio EPA. The most significant problem with the prior version...-21-25 ``Control of VOC emissions from reinforced plastic composites production operations,'' which...
Trace Contaminant Control During the International Space Station's On-Orbit Assembly and Outfitting
NASA Technical Reports Server (NTRS)
Perry, J. L.
2017-01-01
Achieving acceptable cabin air quality must balance competing elements during spacecraft design, assembly, ground processing, and flight operations. Among the elements that contribute to the trace chemical contaminant load and, therefore, the cabin air quality aboard crewed spacecraft are the vehicle configuration, crew size and activities, mission duration and objectives, materials selection, and vehicle manufacturing and preflight ground processing methods. Trace chemical contaminants produced from pervasive sources such as equipment offgassing, human metabolism, and cleaning fluids during preflight ground processing present challenges to maintaining acceptable cabin air quality. To address these challenges, both passive and active contamination control techniques are used during a spacecraft's design, manufacturing, preflight preparation, and operational phases. Passive contamination control methods seek to minimize the equipment offgassing load by selecting materials, manufacturing processes, preflight preparation processes, and in-flight operations that have low chemical offgassing characteristics. Passive methods can be employed across the spacecraft's entire life cycle from conceptual design through flight operations. However, because the passive contamination control techniques cannot fully eliminate the contaminant load, active contamination control equipment must be deployed aboard the spacecraft to purify and revitalize the cabin atmosphere during in-flight operations. Verifying that the passive contamination control techniques have successfully maintained the total trace contaminant load within the active contamination control equipment's capabilities occurs late in the preflight preparation stages. This verification consists of subjecting the spacecraft to an offgassing test to determine the trace contaminant load. This load is then assessed versus the active contamination control equipment's capabilities via trace contaminant control (TCC) engineering analysis. During the International Space Station's (ISS's) on-orbit assembly and outfitting, a series of engineering analyses were conducted to evaluate how effective the passive TCC methods were relative to providing adequate operational margin for the active TCC equipment's capabilities aboard the ISS. These analyses were based on habitable module and cargo vehicle offgassing test results. The offgassing test for a fully assembled module or cargo vehicle is an important preflight spacecraft evaluation method that has been used successfully during all crewed spacecraft programs to provide insight into how effectively the passive contamination control methods limit the equipment offgassing component of the overall trace contaminant generation load. The progression of TCC assessments beginning in 1998 with the ISS's first habitable element launch and continuing through the final pressurized element's arrival in 2010 are presented. Early cargo vehicle flight assessments between 2008 and 2011 are also presented as well as a discussion on predictive methods for assessing cargo via a purely analytical technique. The technical approach for TCC employed during this 13-year period successfully maintained the cabin atmospheric quality within specified parameters during the technically challenging ISS assembly and outfitting stages. The following narrative provides details on the important role of spacecraft offgassing testing, trace contaminant performance requirements, and flight rules for achieving the ultimate result-a cabin environment that enables people to live and work safely in space.
Lin, Susie; McKenna, Samuel J; Yao, Chuan-Fong; Chen, Yu-Ray; Chen, Chit
2017-01-01
The objective of this study was to evaluate the efficacy of hypotensive anesthesia in reducing intraoperative blood loss, decreasing operation time, and improving the quality of the surgical field during orthognathic surgery. A systematic review and meta-analysis of randomized controlled trials addressing these issues were carried out. An electronic database search was performed. The risk of bias was evaluated with the Jadad Scale and Delphi List. The inverse variance statistical method and a random-effects model were used. Ten randomized controlled trials were included for analysis. Our meta-analysis indicated that hypotensive anesthesia reduced intraoperative blood loss by a mean of about 169 mL. Hypotensive anesthesia was not shown to reduce the operation time for orthognathic surgery, but it did improve the quality of the surgical field. Subgroup analysis indicated that for blood loss in double-jaw surgery, the weighted mean difference favored the hypotensive group, with a reduction in blood loss of 175 mL, but no statistically significant reduction in blood loss was found for anterior maxillary osteotomy. If local anesthesia with epinephrine was used in conjunction with hypotensive anesthesia, the reduction in intraoperative blood loss was increased to 254.93 mL. Hypotensive anesthesia was effective in reducing blood loss and improving the quality of the surgical field, but it did not reduce the operation time for orthognathic surgery. The use of local anesthesia in conjunction with hypotensive general anesthesia further reduced the amount of intraoperative blood loss for orthognathic surgery. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Solis, R.P.; Chavez, F.C.; Garcia, S.E.
1997-12-31
In any operating geothermal power plant, steam quality is one of the most important parameters being monitored. In the Bacon-Manito Geothermal Production Field (BGPF), an online steam quality monitoring system have been installed in two operating power plants which provides an accurate, efficient and continuous real-time data which is more responsive to the various requirements of the field operation. The system utilizes sodium as an indicator of steam purity. Sodium concentration is read by the flame photometer located at the interface after aspirating a sample of the condensed steam through a continuous condensate sampler. The condensate has been degassed throughmore » a condensate-NCG separator. The flame photometer analog signal is then converted by a voltage-to-current converter/transmitter and relayed to the processor which is located at the control center through electrical cable to give a digital sodium concentration read-out at the control panel. The system features a high and high-high sodium level alarm, a continuous strip-chart recorder and a central computer for data capture, retrieval, and processing for further interpretation. Safety devices, such as the flame-off indicator at the control center and the automatic fuel cut-off device along the fuel line, are incorporated in the system.« less
Conjoint Analysis for New Service Development on Electricity Distribution in Indonesia
NASA Astrophysics Data System (ADS)
Widaningrum, D. L.; Chynthia; Astuti, L. D.; Seran, M. A. B.
2017-07-01
Many cases of illegal use of electricity in Indonesia is still rampant, especially for activities where the power source is not available, such as in the location of street vendors. It is not only detrimental to the state, but also harm the perpetrators of theft of electricity and the surrounding communities. The purpose of this study is to create New Service Development (NSD) to provide a new electricity source for street vendors' activity based on their preferences. The methods applied in NSD is Conjoint Analysis, Cluster Analysis, Quality Function Deployment (QFD), Service Blueprint, Process Flow Diagrams and Quality Control Plan. The results of this study are the attributes and their importance in the new electricity’s service based on street vendors’ preferences as customers, customer segmentation, service design for new service, designing technical response, designing operational procedures, the quality control plan of any existing operational procedures.
Yan, Binjun; Fang, Zhonghua; Shen, Lijuan; Qu, Haibin
2015-01-01
The batch-to-batch quality consistency of herbal drugs has always been an important issue. To propose a methodology for batch-to-batch quality control based on HPLC-MS fingerprints and process knowledgebase. The extraction process of Compound E-jiao Oral Liquid was taken as a case study. After establishing the HPLC-MS fingerprint analysis method, the fingerprints of the extract solutions produced under normal and abnormal operation conditions were obtained. Multivariate statistical models were built for fault detection and a discriminant analysis model was built using the probabilistic discriminant partial-least-squares method for fault diagnosis. Based on multivariate statistical analysis, process knowledge was acquired and the cause-effect relationship between process deviations and quality defects was revealed. The quality defects were detected successfully by multivariate statistical control charts and the type of process deviations were diagnosed correctly by discriminant analysis. This work has demonstrated the benefits of combining HPLC-MS fingerprints, process knowledge and multivariate analysis for the quality control of herbal drugs. Copyright © 2015 John Wiley & Sons, Ltd.
Mold Heating and Cooling Pump Package Operator Interface Controls Upgrade
DOE Office of Scientific and Technical Information (OSTI.GOV)
Josh A. Salmond
2009-08-07
The modernization of the Mold Heating and Cooling Pump Package Operator Interface (MHC PP OI) consisted of upgrading the antiquated single board computer with a proprietary operating system to off-the-shelf hardware and off-the-shelf software with customizable software options. The pump package is the machine interface between a central heating and cooling system that pumps heat transfer fluid through an injection or compression mold base on a local plastic molding machine. The operator interface provides the intelligent means of controlling this pumping process. Strict temperature control of a mold allows the production of high quality parts with tight tolerances and lowmore » residual stresses. The products fabricated are used on multiple programs.« less
Manufacturing Squares: An Integrative Statistical Process Control Exercise
ERIC Educational Resources Information Center
Coy, Steven P.
2016-01-01
In the exercise, students in a junior-level operations management class are asked to manufacture a simple product. Given product specifications, they must design a production process, create roles and design jobs for each team member, and develop a statistical process control plan that efficiently and effectively controls quality during…
Harvey A. Holt
1989-01-01
Controlling individual unwanted trees in forest stands is a readily accepted method for improving the value of future harvests. The practice is especially important in mixed hardwood forests where species differ considerably in value and within species individual trees differ in quality. Individual stem control is a mechanical or chemical weeding operation that...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-16
... Miscellaneous Metal and Plastic Parts Which Includes Pleasure Craft Coating Operations AGENCY: Environmental... recommended by EPA's control technique guidelines (CTG) for Miscellaneous Metal Parts and Plastic Coating... air pollution control authorities information that should assist them in determining RACT for VOC from...
NASA Astrophysics Data System (ADS)
Azorskii, N. I.; Gusakov, Yu. V.; Elsha, V. V.; Enik, T. L.; Ershov, Yu. V.; Kekelidze, V. D.; Kislov, E. M.; Kolesnikov, A. O.; Madigozhin, D. T.; Movchan, S. A.; Polenkevich, I. A.; Potrebenikov, Yu. K.; Samsonov, V. A.; Shkarovskiy, S. N.; Sotnikov, A. N.; Volkov, A. D.; Zinchenko, A. I.
2017-01-01
A device for fabricating thin-wall (straw) drift tubes using polyethylene terephthalate film 36 μm thick by ultrasonic welding is described together with the technique for controlling their quality. The joint width amounts to 0.4-1.0 mm. The joint breaking strength is 31.9 kg/mm2. The argon leakage from a tube of volume 188.6 cm3 under a pressure gradient of 1.0 atm does not exceed 0.3 × 10-3 cm3/min, which is mainly related to the absence of metallization in the joint vicinity. The high strength, the low tensile creep due to the absence of glued layers, the small value of gas leakage makes the new tubes capable of reliable and long-term operation in vacuum, which is confirmed by the operation of 7168 straw tubes for two years in the NA62 experiment.
Biofilm formation and control in a simulated spacecraft water system - Two-year results
NASA Technical Reports Server (NTRS)
Schultz, John R.; Taylor, Robert D.; Flanagan, David T.; Carr, Sandra E.; Bruce, Rebekah J.; Svoboda, Judy V.; Huls, M. H.; Sauer, Richard L.; Pierson, Duane L.
1991-01-01
The ability of iodine to maintain microbial water quality in a simulated spacecraft water system is being studied. An iodine level of about 2.0 mg/L is maintained by passing ultrapure influent water through an iodinated ion exchange resin. Six liters are withdrawn daily and the chemical and microbial quality of the water is monitored regularly. Stainless steel coupons used to monitor biofilm formation are being analyzed by culture methods, epifluorescence microscopy, and scanning electron microscopy. Results from the first two years of operation show a single episode of high bacterial colony counts in the iodinated system. This growth was apparently controlled by replacing the iodinated ion exchange resin. Scanning electron microscopy indicates that the iodine has limited but not completely eliminated the formation of biofilm during the first two years of operation. Significant microbial contamination has been present continuously in a parallel noniodinated system since the third week of operation.
13 CFR 120.1050 - On-site reviews and examinations.
Code of Federal Regulations, 2010 CFR
2010-01-01
... operations management; (3) Credit administration; and (4) Compliance with Loan Program Requirements. (b) On... reviews. SBA may conduct on-site reviews of the SBA loan operations of SBA Lenders. The on-site review may... losses); (3) Management quality (including internal controls, loan portfolio management, and asset...
Quality Control Specialist | Center for Cancer Research
Within the Leidos Biomedical Research Inc.’s Clinical Research Directorate, the Clinical Monitoring Research Program (CMRP) provides high-quality comprehensive and strategic operational support to the high-profile domestic and international clinical research initiatives of the National Cancer Institute (NCI), National Institute of Allergy and Infectious Diseases (NIAID),
40 CFR 63.6135 - How do I monitor and collect data to demonstrate continuous compliance?
Code of Federal Regulations, 2012 CFR
2012-07-01
... Combustion Turbines Continuous Compliance Requirements § 63.6135 How do I monitor and collect data to... quality assurance or quality control activities (including, as applicable, calibration checks and required... times the stationary combustion turbine is operating. (b) Do not use data recorded during monitor...
40 CFR 63.6135 - How do I monitor and collect data to demonstrate continuous compliance?
Code of Federal Regulations, 2013 CFR
2013-07-01
... Combustion Turbines Continuous Compliance Requirements § 63.6135 How do I monitor and collect data to... quality assurance or quality control activities (including, as applicable, calibration checks and required... times the stationary combustion turbine is operating. (b) Do not use data recorded during monitor...
40 CFR 63.6135 - How do I monitor and collect data to demonstrate continuous compliance?
Code of Federal Regulations, 2014 CFR
2014-07-01
... Combustion Turbines Continuous Compliance Requirements § 63.6135 How do I monitor and collect data to... quality assurance or quality control activities (including, as applicable, calibration checks and required... times the stationary combustion turbine is operating. (b) Do not use data recorded during monitor...
NASA Astrophysics Data System (ADS)
Galelli, Stefano; Goedbloed, Albert; Schmitter, Petra; Castelletti, Andrea
2014-05-01
Urban water reservoirs are a viable adaptation option to account for increasing drinking water demand of urbanized areas as they allow storage and re-use of water that is normally lost. In addition, the direct availability of freshwater reduces pumping costs and diversifies the portfolios of drinking water supply. Yet, these benefits have an associated twofold cost. Firstly, the presence of large, impervious areas increases the hydraulic efficiency of urban catchments, with short time of concentration, increased runoff rates, losses of infiltration and baseflow, and higher risk of flash floods. Secondly, the high concentration of nutrients and sediments characterizing urban discharges is likely to cause water quality problems. In this study we propose a new control scheme combining Model Predictive Control (MPC), hydro-meteorological forecasts and dynamic model emulation to design real-time operating policies that conjunctively optimize water quantity and quality targets. The main advantage of this scheme stands in its capability of exploiting real-time hydro-meteorological forecasts, which are crucial in such fast-varying systems. In addition, the reduced computational requests of the MPC scheme allows coupling it with dynamic emulators of water quality processes. The approach is demonstrated on Marina Reservoir, a multi-purpose reservoir located in the heart of Singapore and characterized by a large, highly urbanized catchment with a short (i.e. approximately one hour) time of concentration. Results show that the MPC scheme, coupled with a water quality emulator, provides a good compromise between different operating objectives, namely flood risk reduction, drinking water supply and salinity control. Finally, the scheme is used to assess the effect of source control measures (e.g. green roofs) aimed at restoring the natural hydrological regime of Marina Reservoir catchment.
Astaraie-Imani, Maryam; Kapelan, Zoran; Fu, Guangtao; Butler, David
2012-12-15
Climate change and urbanisation are key factors affecting the future of water quality and quantity in urbanised catchments and are associated with significant uncertainty. The work reported in this paper is an evaluation of the combined and relative impacts of climate change and urbanisation on the receiving water quality in the context of an Integrated Urban Wastewater System (IUWS) in the UK. The impacts of intervening system operational control parameters are also investigated. Impact is determined by a detailed modelling study using both local and global sensitivity analysis methods together with correlation analysis. The results obtained from the case-study analysed clearly demonstrate that climate change combined with increasing urbanisation is likely to lead to worsening river water quality in terms of both frequency and magnitude of breaching threshold dissolved oxygen and ammonium concentrations. The results obtained also reveal the key climate change and urbanisation parameters that have the largest negative impact as well as the most responsive IUWS operational control parameters including major dependencies between all these parameters. This information can be further utilised to adapt future IUWS operation and/or design which, in turn, should make these systems more resilient to future climate and urbanisation changes. Copyright © 2012 Elsevier Ltd. All rights reserved.
2002-08-21
The Audit Division provides the Commander, U.S. Special Operations Command (USSOCOM) with professional auditing services to safeguard, account for...and ensure the proper use of special operations forces assets in accomplishing the USSOCOM mission. The Audit Division reports to the USSOCOM Inspector...U.S. Army Special Operations Command, Naval Special Warfare Command, and the Joint Special Operations Command. Appendix A contains a summary of the Audit Division policy and procedures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gilliam, T.M.
1991-05-01
This Project Quality Assurance Plan (PQAP) sets forth the quality assurance (QA) requirements that are applied to those elements of the Westinghouse Materials Company of Ohio (WMCO) Operable Unit 1 support at Oak Ridge National Laboratory (ORNL) project that involve research and development (R D) performed at ORNL. This is in compliance with the applicable criteria of 10 CFR Part 50, Appendix B, ANSI/ASME NQA-1, as specified by Department of Energy (DOE) Oak Ridge Operations (ORO) Order 5700.6B. For this application, NQA-1 is the core QA Program requirements document. QA policy, normally found in the requirements document, is contained herein.more » The requirements of this PQAP apply to project activities that affect the quality and reliability/credibility of research, development, and investigative data and documentation. These activities include the functions of attaining quality objectives and assuring that an appropriate QA program scope is established. The scope of activities affecting quality includes organization; personnel training and qualifications; design control; procurement; material handling and storage; operating procedures; testing, surveillance, and auditing; R D investigative activities and documentation; deficiencies; corrective actions; and QA record keeping. 12 figs.« less
NASA Astrophysics Data System (ADS)
Pattalwar, Shrikant; Jones, Thomas; Strachan, John; Bate, Robert; Davies, Phil; McIntosh, Peter
2012-06-01
Through an international cryomodule collaboration, ASTeC at Daresbury Laboratory has taken the primary responsibility in leading the development of an optimised Superconducting RF (SRF) cryomodule, operating in CW mode for energy recovery facilities and other high duty cycle accelerators. For high beam current operation, Higher Order Mode (HOM) absorbers are critical components of the SRF Cryomodule, ensuring excessive heating of the accelerating structures and beam instabilities are effectively managed. This paper describes some of the cold tests conducted on the HOM absorbers and other critical components during the construction phase, to ensure that the quality and reliable cryomodule performance is maintained.
Review of nuclear pharmacy practice in hospitals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kawada, T.K.; Tubis, M.; Ebenkamp, T.
1982-02-01
An operational profile for nuclear pharmacy practice is presented, and the technical and professional role of nuclear pharmacists is reviewed. Key aspects of nuclear pharmacy practice in hospitals discussed are the basic facilities and equipment for the preparation, quality control, and distribution of radioactive drug products. Standards for receiving, storing, and processing radioactive material are described. The elements of a radiopharmaceutical quality assurance program, including the working procedures, documentation systems, data analysis, and specific control tests, are presented. Details of dose preparation and administration and systems of inventory control for radioactive products are outlined.
The Fate of Trace Contaminants in a Crewed Spacecraft Cabin Environment
NASA Technical Reports Server (NTRS)
Perry, Jay L.; Kayatin, Matthew J.
2016-01-01
Trace chemical contaminants produced via equipment offgassing, human metabolic sources, and vehicle operations are removed from the cabin atmosphere by active contamination control equipment and incidental removal by other air quality control equipment. The fate of representative trace contaminants commonly observed in spacecraft cabin atmospheres is explored. Removal mechanisms are described and predictive mass balance techniques are reviewed. Results from the predictive techniques are compared to cabin air quality analysis results. Considerations are discussed for an integrated trace contaminant control architecture suitable for long duration crewed space exploration missions.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-31
... October 7, 2008 (73 FR 58481), EPA updated the 1977 CTG, as part of Group IV CTG, addressing the control... Group III CTG, addressing control of VOC emissions from metal furniture coating operations. On January 3..., as part of Group III CTG, addressing the control of VOC emissions from large appliance surface...
Design optimization for cost and quality: The robust design approach
NASA Technical Reports Server (NTRS)
Unal, Resit
1990-01-01
Designing reliable, low cost, and operable space systems has become the key to future space operations. Designing high quality space systems at low cost is an economic and technological challenge to the designer. A systematic and efficient way to meet this challenge is a new method of design optimization for performance, quality, and cost, called Robust Design. Robust Design is an approach for design optimization. It consists of: making system performance insensitive to material and subsystem variation, thus allowing the use of less costly materials and components; making designs less sensitive to the variations in the operating environment, thus improving reliability and reducing operating costs; and using a new structured development process so that engineering time is used most productively. The objective in Robust Design is to select the best combination of controllable design parameters so that the system is most robust to uncontrollable noise factors. The robust design methodology uses a mathematical tool called an orthogonal array, from design of experiments theory, to study a large number of decision variables with a significantly small number of experiments. Robust design also uses a statistical measure of performance, called a signal-to-noise ratio, from electrical control theory, to evaluate the level of performance and the effect of noise factors. The purpose is to investigate the Robust Design methodology for improving quality and cost, demonstrate its application by the use of an example, and suggest its use as an integral part of space system design process.
Testing and checkout experiences in the National Transonic Facility since becoming operational
NASA Technical Reports Server (NTRS)
Bruce, W. E., Jr.; Gloss, B. B.; Mckinney, L. W.
1988-01-01
The U.S. National Transonic Facility, constructed by NASA to meet the national needs for High Reynolds Number Testing, has been operational in a checkout and test mode since the operational readiness review (ORR) in late 1984. During this time, there have been problems centered around the effect of large temperature excursions on the mechanical movement of large components, the reliable performance of instrumentation systems, and an unexpected moisture problem with dry insulation. The more significant efforts since the ORR are reviewed and NTF status concerning hardware, instrumentation and process controls systems, operating constraints imposed by the cryogenic environment, and data quality and process controls is summarized.
Myerson, Allan S; Krumme, Markus; Nasr, Moheb; Thomas, Hayden; Braatz, Richard D
2015-03-01
This white paper provides a perspective of the challenges, research needs, and future directions for control systems engineering in continuous pharmaceutical processing. The main motivation for writing this paper is to facilitate the development and deployment of control systems technologies so as to ensure quality of the drug product. Although the main focus is on small-molecule pharmaceutical products, most of the same statements apply to biological drug products. An introduction to continuous manufacturing and control systems is followed by a discussion of the current status and technical needs in process monitoring and control, systems integration, and risk analysis. Some key points are that: (1) the desired objective in continuous manufacturing should be the satisfaction of all critical quality attributes (CQAs), not for all variables to operate at steady-state values; (2) the design of start-up and shutdown procedures can significantly affect the economic operation of a continuous manufacturing process; (3) the traceability of material as it moves through the manufacturing facility is an important consideration that can at least in part be addressed using residence time distributions; and (4) the control systems technologies must assure quality in the presence of disturbances, dynamics, uncertainties, nonlinearities, and constraints. Direct measurement, first-principles and empirical model-based predictions, and design space approaches are described for ensuring that CQA specifications are met. Ways are discussed for universities, regulatory bodies, and industry to facilitate working around or through barriers to the development of control systems engineering technologies for continuous drug manufacturing. Industry and regulatory bodies should work with federal agencies to create federal funding mechanisms to attract faculty to this area. Universities should hire faculty interested in developing first-principles models and control systems technologies for drug manufacturing that are easily transportable to industry. Industry can facilitate the move to continuous manufacturing by working with universities on the conception of new continuous pharmaceutical manufacturing process unit operations that have the potential to make major improvements in product quality, controllability, or reduced capital and/or operating costs. Regulatory bodies should ensure that: (1) regulations and regulatory practices promote, and do not derail, the development and implementation of continuous manufacturing and control systems engineering approaches; (2) the individuals who approve specific regulatory filings are sufficiently trained to make good decisions regarding control systems approaches; (3) provide regulatory clarity and eliminate/reduce regulatory risks; (4) financially support the development of high-quality training materials for use of undergraduate students, graduate students, industrial employees, and regulatory staff; (5) enhance the training of their own technical staff by financially supporting joint research projects with universities in the development of continuous pharmaceutical manufacturing processes and the associated control systems engineering theory, numerical algorithms, and software; and (6) strongly encourage the federal agencies that support research to fund these research areas. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.
Myerson, Allan S; Krumme, Markus; Nasr, Moheb; Thomas, Hayden; Braatz, Richard D
2015-03-01
This white paper provides a perspective of the challenges, research needs, and future directions for control systems engineering in continuous pharmaceutical processing. The main motivation for writing this paper is to facilitate the development and deployment of control systems technologies so as to ensure quality of the drug product. Although the main focus is on small-molecule pharmaceutical products, most of the same statements apply to biological drug products. An introduction to continuous manufacturing and control systems is followed by a discussion of the current status and technical needs in process monitoring and control, systems integration, and risk analysis. Some key points are that: (1) the desired objective in continuous manufacturing should be the satisfaction of all critical quality attributes (CQAs), not for all variables to operate at steady-state values; (2) the design of start-up and shutdown procedures can significantly affect the economic operation of a continuous manufacturing process; (3) the traceability of material as it moves through the manufacturing facility is an important consideration that can at least in part be addressed using residence time distributions; and (4) the control systems technologies must assure quality in the presence of disturbances, dynamics, uncertainties, nonlinearities, and constraints. Direct measurement, first-principles and empirical model-based predictions, and design space approaches are described for ensuring that CQA specifications are met. Ways are discussed for universities, regulatory bodies, and industry to facilitate working around or through barriers to the development of control systems engineering technologies for continuous drug manufacturing. Industry and regulatory bodies should work with federal agencies to create federal funding mechanisms to attract faculty to this area. Universities should hire faculty interested in developing first-principles models and control systems technologies for drug manufacturing that are easily transportable to industry. Industry can facilitate the move to continuous manufacturing by working with universities on the conception of new continuous pharmaceutical manufacturing process unit operations that have the potential to make major improvements in product quality, controllability, or reduced capital and/or operating costs. Regulatory bodies should ensure that: (1) regulations and regulatory practices promote, and do not derail, the development and implementation of continuous manufacturing and control systems engineering approaches; (2) the individuals who approve specific regulatory filings are sufficiently trained to make good decisions regarding control systems approaches; (3) provide regulatory clarity and eliminate/reduce regulatory risks; (4) financially support the development of high-quality training materials for use of undergraduate students, graduate students, industrial employees, and regulatory staff; (5) enhance the training of their own technical staff by financially supporting joint research projects with universities in the development of continuous pharmaceutical manufacturing processes and the associated control systems engineering theory, numerical algorithms, and software; and (6) strongly encourage the federal agencies that support research to fund these research areas. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.
NASA Astrophysics Data System (ADS)
Zhu, Junjie
Aeration accounts for a large fraction of energy consumption in conventional water reclamation plants (WRPs). Although process operations at older WRPs can satisfy effluent permit requirements, they typically operate with excess aeration. More effective process controls at older WRPs can be challenging as operators work to balance higher energy costs and more stringent effluent limitations while managing fluctuating loads. Therefore, understandings of process resilience or ability to quickly return to original operation conditions at a WRP are important. A state-of-art WRP should maintain process resilience to deal with different kinds of perturbations even after optimization of energy demands. This work was to evaluate the applicability and feasibility of cyber-physical system (CPS) for improving operation at Metropolitan Water Reclamation District of Greater Chicago (MWRDGC) Calumet WRP. In this work, a process model was developed and used to better understand the conditions of current Calumet WRP, with additional valuable information from two dissolved oxygen field measurements. Meanwhile, a classification system was developed to reveal the pattern of historical influent scenario based on cluster analysis and cross-tabulation analysis. Based on the results from the classification, typical process control options were investigated. To ensure the feasibility of information acquisition, the reliability and flexibility of soft sensors were assessed to typical influent conditions. Finally, the process resilience was investigated to better balance influent perturbations, energy demands, and effluent quality for long-term operations. These investigations and evaluations show that although the energy demands change as the influent conditions and process controls. In general, aeration savings could be up to 50% from the level of current consumption; with a more complex process controls, the saving could be up to 70% in relatively steady-state conditions and at least 40% in relatively challenging transient conditions. The soft sensors can provide reliable and flexible performance on target predictions. The plant can still maintain at a similar level of process resilience after 50% aeration saving, even during long-term perturbations. Overall, this work shows that it is well feasible to provide more cost-effective operations at the Calumet WRP, and meanwhile influent perturbations, effluent quality, and process resilience are well in balance.
40 CFR 63.2270 - How do I monitor and collect data to demonstrate continuous compliance?
Code of Federal Regulations, 2011 CFR
2011-07-01
... appropriate, monitor malfunctions, associated repairs, and required quality assurance or control activities... monitoring in continuous operation at all times that the process unit is operating. For purposes of calculating data averages, you must not use data recorded during monitoring malfunctions, associated repairs...
40 CFR 63.2270 - How do I monitor and collect data to demonstrate continuous compliance?
Code of Federal Regulations, 2010 CFR
2010-07-01
... appropriate, monitor malfunctions, associated repairs, and required quality assurance or control activities... monitoring in continuous operation at all times that the process unit is operating. For purposes of calculating data averages, you must not use data recorded during monitoring malfunctions, associated repairs...
The Evolution of Methods of Air Traffic Control.
1984-01-01
Constraints: The fundemental presupposition of this method is that it is only the aircraft which can make the choice of the most cost-efficient profile...the direct operating costs but the return on investment in the ground equipment. Similarly in operational terms, improving the day-to-day quality of
Improved head-controlled TV system produces high-quality remote image
NASA Technical Reports Server (NTRS)
Goertz, R.; Lindberg, J.; Mingesz, D.; Potts, C.
1967-01-01
Manipulator operator uses an improved resolution tv camera/monitor positioning system to view the remote handling and processing of reactive, flammable, explosive, or contaminated materials. The pan and tilt motions of the camera and monitor are slaved to follow the corresponding motions of the operators head.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-16
... surface coating operations in the Chicago and Metro-East St. Louis 8-hour ozone nonattainment areas. These... available control technology (RACT) policy. DATES: This direct final rule will be effective June 15, 2012... ``small container exemption'' for pleasure craft surface coating operations. EPA previously approved...
NASA Technical Reports Server (NTRS)
Vomaske, R. F.; Innis, R. C.; Swan, B. E.; Grossmith, S. W.
1978-01-01
The stability, control, and handling qualities of an augmented jet flap STOL airplane are presented. The airplane is an extensively modified de Havilland Buffalo military transport. The modified airplane has two fan-jet engines which provide vectorable thrust and compressed air for the augmentor jet flap and Boundary-Layer Control (BLC). The augmentor and BLC air is cross ducted to minimize asymmetric moments produced when one engine is inoperative. The modifications incorporated in the airplane include a Stability Augmentation System (SAS), a powered elevator, and a powered lateral control system. The test gross weight of the airplane was between 165,000 and 209,000 N (37,000 and 47,000 lb). Stability, control, and handling qualities are presented for the airspeed range of 40 to 180 knots. The lateral-directional handling qualities are considered satisfactory for the normal operating range of 65 to 160 knots airspeed when the SAS is functioning. With the SAS inoperative, poor turn coordination and spiral instability are primary deficiencies contributing to marginal handling qualities in the landing approach. The powered elevator control system enhanced the controllability in pitch, particularly in the landing flare and stall recovery.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kegel, T.M.
Calibration laboratories are faced with the need to become accredited or registered to one or more quality standards. One requirement common to all of these standards is the need to have in place a measurement assurance program. What is a measurement assurance program? Brian Belanger, in Measurement Assurance Programs: Part 1, describes it as a {open_quotes}quality assurance program for a measurement process that quantifies the total uncertainty of the measurements (both random and systematic components of error) with respect to national or designated standards and demonstrates that the total uncertainty is sufficiently small to meet the user`s requirements.{close_quotes} Rolf Schumachermore » is more specific in Measurement Assurance in Your Own Laboratory. He states, {open_quotes}Measurement assurance is the application of broad quality control principles to measurements of calibrations.{close_quotes} Here, the focus is on one important part of any measurement assurance program: implementation of statistical process control (SPC). Paraphrasing Juran`s Quality Control Handbook, a process is in statistical control if the only observed variations are those that can be attributed to random causes. Conversely, a process that exhibits variations due to assignable causes is not in a state of statistical control. Finally, Carrol Croarkin states, {open_quotes}In the measurement assurance context the measurement algorithm including instrumentation, reference standards and operator interactions is the process that is to be controlled, and its direct product is the measurement per se. The measurements are assumed to be valid if the measurement algorithm is operating in a state of control.{close_quotes} Implicit in this statement is the important fact that an out-of-control process cannot produce valid measurements. 7 figs.« less
Smith, Alan D
2011-01-01
A general overview of various blood products operational effectiveness and related strategies that can be utilised by service providers (in particular, healthcare providers) is presented in the present study. In terms of the massive volumes of blood products, the North American blood centres collect more than eight million units of whole blood, which represents appropriately 50% of the US and Quebec, Canada?s volunteer donor blood supply. A case study of the quality inspection and inventory control concerns of the Central Blood Bank, located in the metropolitan area of Pittsburgh, PA, is presented. Initially, brief introduction to its general operating environment is followed by sections describing its general situation, quality-service initiatives, and followed by a fairly detailed discussion of the practical applications of lessons learned from the case study.
Sotelo, David; Favela-Contreras, Antonio; Sotelo, Carlos; Jiménez, Guillermo; Gallegos-Canales, Luis
2017-11-01
In recent years, interest for petrochemical processes has been increasing, especially in refinement area. However, the high variability in the dynamic characteristics present in the atmospheric distillation column poses a challenge to obtain quality products. To improve distillates quality in spite of the changes in the input crude oil composition, this paper details a new design of a control strategy in a conventional crude oil distillation plant defined using formal interaction analysis tools. The process dynamic and its control are simulated on Aspen HYSYS ® dynamic environment under real operating conditions. The simulation results are compared against a typical control strategy commonly used in crude oil atmospheric distillation columns. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.
Twentieth Annual Conference on Manual Control, Volume 1
NASA Technical Reports Server (NTRS)
Hart, S. G. (Compiler); Hartzell, E. J. (Compiler)
1984-01-01
The 48 papers presented were devoted to humanopeator modeling, application of models to simulation and operational environments, aircraft handling qualities, teleopertors, fault diagnosis, and biodynamics.
Bartholomay, Roy C.; Maimer, Neil V.; Wehnke, Amy J.
2014-01-01
Water-quality activities and water-level measurements by the personnel of the U.S. Geological Survey (USGS) Idaho National Laboratory (INL) Project Office coincide with the USGS mission of appraising the quantity and quality of the Nation’s water resources. The activities are carried out in cooperation with the U.S. Department of Energy (DOE) Idaho Operations Office. Results of the water-quality and hydraulic head investigations are presented in various USGS publications or in refereed scientific journals and the data are stored in the National Water Information System (NWIS) database. The results of the studies are used by researchers, regulatory and managerial agencies, and interested civic groups. In the broadest sense, quality assurance refers to doing the job right the first time. It includes the functions of planning for products, review and acceptance of the products, and an audit designed to evaluate the system that produces the products. Quality control and quality assurance differ in that quality control ensures that things are done correctly given the “state-of-the-art” technology, and quality assurance ensures that quality control is maintained within specified limits.
A pH-Regulated Quality Control Cycle for Surveillance of Secretory Protein Assembly
Vavassori, Stefano; Cortini, Margherita; Masui, Shoji; Sannino, Sara; Anelli, Tiziana; Caserta, Imma R.; Fagioli, Claudio; Mossuto, Maria F.; Fornili, Arianna; van Anken, Eelco; Degano, Massimo; Inaba, Kenji; Sitia, Roberto
2013-01-01
Summary To warrant the quality of the secretory proteome, stringent control systems operate at the endoplasmic reticulum (ER)-Golgi interface, preventing the release of nonnative products. Incompletely assembled oligomeric proteins that are deemed correctly folded must rely on additional quality control mechanisms dedicated to proper assembly. Here we unveil how ERp44 cycles between cisGolgi and ER in a pH-regulated manner, patrolling assembly of disulfide-linked oligomers such as IgM and adiponectin. At neutral, ER-equivalent pH, the ERp44 carboxy-terminal tail occludes the substrate-binding site. At the lower pH of the cisGolgi, conformational rearrangements of this peptide, likely involving protonation of ERp44’s active cysteine, simultaneously unmask the substrate binding site and −RDEL motif, allowing capture of orphan secretory protein subunits and ER retrieval via KDEL receptors. The ERp44 assembly control cycle couples secretion fidelity and efficiency downstream of the calnexin/calreticulin and BiP-dependent quality control cycles. PMID:23685074
Manual control models of industrial management
NASA Technical Reports Server (NTRS)
Crossman, E. R. F. W.
1972-01-01
The industrial engineer is often required to design and implement control systems and organization for manufacturing and service facilities, to optimize quality, delivery, and yield, and minimize cost. Despite progress in computer science most such systems still employ human operators and managers as real-time control elements. Manual control theory should therefore be applicable to at least some aspects of industrial system design and operations. Formulation of adequate model structures is an essential prerequisite to progress in this area; since real-world production systems invariably include multilevel and multiloop control, and are implemented by timeshared human effort. A modular structure incorporating certain new types of functional element, has been developed. This forms the basis for analysis of an industrial process operation. In this case it appears that managerial controllers operate in a discrete predictive mode based on fast time modelling, with sampling interval related to plant dynamics. Successive aggregation causes reduced response bandwidth and hence increased sampling interval as a function of level.
MEMS tunable grating micro-spectrometer
NASA Astrophysics Data System (ADS)
Tormen, Maurizio; Lockhart, R.; Niedermann, P.; Overstolz, T.; Hoogerwerf, A.; Mayor, J.-M.; Pierer, J.; Bosshard, C.; Ischer, R.; Voirin, G.; Stanley, R. P.
2017-11-01
The interest in MEMS based Micro-Spectrometers is increasing due to their potential in terms of flexibility as well as cost, low mass, small volume and power savings. This interest, especially in the Near-Infrared and Mid- Infrared, ranges from planetary exploration missions to astronomy, e.g. the search for extra solar planets, as well as to many other terrestrial fields of application such as, industrial quality and surface control, chemical analysis of soil and water, detection of chemical pollutants, exhausted gas analysis, food quality control, process control in pharmaceuticals, to name a few. A compact MEMS-based Spectrometer for Near- Infrared and Mid-InfraRed operation have been conceived, designed and demonstrated. The design based on tunable MEMS blazed grating, developed in the past at CSEM [1], achieves state of the art results in terms of spectral resolution, operational wavelength range, light throughput, overall dimensions, and power consumption.
Water quality and nitrogen mass loss from anaerobic lagoon columns receiving pretreated influent
USDA-ARS?s Scientific Manuscript database
Control methods are needed to abate ammonia losses from swine anaerobic lagoons to reduce contribution of confined swine operations to air pollution. In a 15-month meso-scale column study, we evaluated the effect of manure pretreatment on water quality, reduction of N losses, and sludge accumulation...
ERIC Educational Resources Information Center
Mawhinney, Thomas C.
1992-01-01
The history and main features of organizational behavior management (OBM) are compared and integrated with those of total quality management (TQM), with emphasis on W.E. Deming's 14 points and OBM's operant-based approach to performance management. Interventions combining OBM, TQM, and statistical process control are recommended. (DB)
40 CFR Appendix B to Part 75 - Quality Assurance and Quality Control Procedures
Code of Federal Regulations, 2011 CFR
2011-07-01
... suitable for inspection. A maintenance log may be used for this purpose. The following records should be... the previous 26 unit (or stack) operating hours; and (b) the 26 clock hour data validation window for... official test log for each monitoring system. (i) The results of any certification, recertification...
NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR FORM QA/QC CHECKS (UA-C-2.0)
The purpose of this SOP is to outline the process of Field Quality Assurance and Quality Control checks. This procedure was followed to ensure consistent data retrieval during the Arizona NHEXAS project and the "Border" study. Keywords: custody; QA/QC; field checks.
The Nation...
Inverse simulation system for evaluating handling qualities during rendezvous and docking
NASA Astrophysics Data System (ADS)
Zhou, Wanmeng; Wang, Hua; Thomson, Douglas; Tang, Guojin; Zhang, Fan
2017-08-01
The traditional method used for handling qualities assessment of manned space vehicles is too time-consuming to meet the requirements of an increasingly fast design process. In this study, a rendezvous and docking inverse simulation system to assess the handling qualities of spacecraft is proposed using a previously developed model-predictive-control architecture. By considering the fixed discrete force of the thrusters of the system, the inverse model is constructed using the least squares estimation method with a hyper-ellipsoidal restriction, the continuous control outputs of which are subsequently dispersed by pulse width modulation with sensitivity factors introduced. The inputs in every step are deemed constant parameters, and the method could be considered as a general method for solving nominal, redundant, and insufficient inverse problems. The rendezvous and docking inverse simulation is applied to a nine-degrees-of-freedom platform, and a novel handling qualities evaluation scheme is established according to the operation precision and astronauts' workload. Finally, different nominal trajectories are scored by the inverse simulation and an established evaluation scheme. The scores can offer theoretical guidance for astronaut training and more complex operation missions.
van den Ban, Sander; Pitt, Kendal G; Whiteman, Marshall
2018-02-01
A scientific understanding of interaction of product, film coat, film coating process, and equipment is important to enable design and operation of industrial scale pharmaceutical film coating processes that are robust and provide the level of control required to consistently deliver quality film coated product. Thermodynamic film coating conditions provided in the tablet film coating process impact film coat formation and subsequent product quality. A thermodynamic film coating model was used to evaluate film coating process performance over a wide range of film coating equipment from pilot to industrial scale (2.5-400 kg). An approximate process-imposed transition boundary, from operating in a dry to a wet environment, was derived, for relative humidity and exhaust temperature, and used to understand the impact of the film coating process on product formulation and process control requirements. This approximate transition boundary may aid in an enhanced understanding of risk to product quality, application of modern Quality by Design (QbD) based product development, technology transfer and scale-up, and support the science-based justification of critical process parameters (CPPs).
Hu, E; Liao, T. W.; Tiersch, T. R.
2013-01-01
Cryopreservation of fish sperm has been studied for decades at a laboratory (research) scale. However, high-throughput cryopreservation of fish sperm has recently been developed to enable industrial-scale production. This study treated blue catfish (Ictalurus furcatus) sperm high-throughput cryopreservation as a manufacturing production line and initiated quality assurance plan development. The main objectives were to identify: 1) the main production quality characteristics; 2) the process features for quality assurance; 3) the internal quality characteristics and their specification designs; 4) the quality control and process capability evaluation methods, and 5) the directions for further improvements and applications. The essential product quality characteristics were identified as fertility-related characteristics. Specification design which established the tolerance levels according to demand and process constraints was performed based on these quality characteristics. Meanwhile, to ensure integrity throughout the process, internal quality characteristics (characteristics at each quality control point within process) that could affect fertility-related quality characteristics were defined with specifications. Due to the process feature of 100% inspection (quality inspection of every fish), a specific calculation method, use of cumulative sum (CUSUM) control charts, was applied to monitor each quality characteristic. An index of overall process evaluation, process capacity, was analyzed based on in-control process and the designed specifications, which further integrates the quality assurance plan. With the established quality assurance plan, the process could operate stably and quality of products would be reliable. PMID:23872356
Measuring, managing and maximizing refinery performance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bascur, O.A.; Kennedy, J.P.
1996-01-01
Implementing continuous quality improvement is a confluence of total quality management, people empowerment, performance indicators and information engineering. Supporting information technologies allow a refiner to narrow the gap between management objectives and the process control level. Dynamic performance monitoring benefits come from production cost savings, improved communications and enhanced decision making. A refinery workgroup information flow model helps automate continuous improvement of processes, performance and the organization. The paper discusses the rethinking of refinery operations, dynamic performance monitoring, continuous process improvement, the knowledge coordinator and repository manager, an integrated plant operations workflow, and successful implementation.
Lu, Tsung-Hsueh; Li, Sheng-Tun; Liang, Fu-Wen; Lee, Jo-Chi; Yin, Wei-Hsian
2017-10-31
The aim of this quasi-experimental study was to examine whether high-volume percutaneous coronary intervention (PCI) operators still maintain high volume and quality of outcomes when they moved to lower volume hospitals. Systematic reviews have indicated that high-volume PCI operators and hospitals have higher quality outcomes. However, little is known on whether high PCI volume and high quality outcomes are mainly due to operator characteristics (i.e., skill and experience) and is portable across organizations or whether it is due to hospital characteristics (i.e., equipment, team, and management system) and is less portable. We used Taiwan National Health Insurance claims data 2000-2012 to identify 98 high-volume PCI operators, 10 of whom moved from one hospital to another during the study period. We compared the PCI volume, risk-adjusted mortality ratio, and major adverse cardiovascular event (MACE) ratio before and after moving. Of the 10 high-volume operators who moved, 6 moved from high- to moderate- or low-volume hospitals, with median annual PCI volumes (interquartile range) of 130 (117-165) in prior hospitals and 54 (46-84) in subsequent hospitals (the hospital the operator moved to), and the remaining 4 moved from high to high-volume hospitals, with median annual PCI volumes (interquartile range) of 151 (133-162) in prior hospitals and 193 (178-239) in subsequent hospitals. No significant differences were observed in the risk-adjusted mortality ratios and MACE ratios between high-volume operators and matched controls before and after moving. High-volume operators cannot maintain high volume when they moved from high to moderate or low-volume hospitals; however, the quality of care is maintained. High PCI volume and high-quality outcomes are less portable and more hospital bound. © 2017 Wiley Periodicals, Inc.
Environmental Assessment Reserve Military Operations Area
1989-12-01
Control of Vibrations Caused by Blasting. Laboratorio National De Engenharia Civil, Lisboa, Portugal. Memoria 498. 11 p. Federal Air Quality Control...and FHP- 42-1(102) in Largo Creek Valley, Catron County, New Mexico, Gila National Forest. Laboratory of Anthropology Notes No. 144. Museum of New
Longitudinal flying qualities criteria for single-pilot instrument flight operations
NASA Technical Reports Server (NTRS)
Stengel, R. F.; Bar-Gill, A.
1983-01-01
Modern estimation and control theory, flight testing, and statistical analysis were used to deduce flying qualities criteria for General Aviation Single Pilot Instrument Flight Rule (SPIFR) operations. The principal concern is that unsatisfactory aircraft dynamic response combined with high navigation/communication workload can produce problems of safety and efficiency. To alleviate these problems. The relative importance of these factors must be determined. This objective was achieved by flying SPIFR tasks with different aircraft dynamic configurations and assessing the effects of such variations under these conditions. The experimental results yielded quantitative indicators of pilot's performance and workload, and for each of them, multivariate regression was applied to evaluate several candidate flying qualities criteria.
Quality Management Framework for Total Diet Study centres in Europe.
Pité, Marina; Pinchen, Hannah; Castanheira, Isabel; Oliveira, Luisa; Roe, Mark; Ruprich, Jiri; Rehurkova, Irena; Sirot, Veronique; Papadopoulos, Alexandra; Gunnlaugsdóttir, Helga; Reykdal, Ólafur; Lindtner, Oliver; Ritvanen, Tiina; Finglas, Paul
2018-02-01
A Quality Management Framework to improve quality and harmonization of Total Diet Study practices in Europe was developed within the TDS-Exposure Project. Seventeen processes were identified and hazards, Critical Control Points and associated preventive and corrective measures described. The Total Diet Study process was summarized in a flowchart divided into planning and practical (sample collection, preparation and analysis; risk assessment analysis and publication) phases. Standard Operating Procedures were developed and implemented in pilot studies in five organizations. The flowchart was used to develop a quality framework for Total Diet Studies that could be included in formal quality management systems. Pilot studies operated by four project partners were visited by project assessors who reviewed implementation of the proposed framework and identified areas that could be improved. The quality framework developed can be the starting point for any Total Diet Study centre and can be used within existing formal quality management approaches. Copyright © 2017 Elsevier Ltd. All rights reserved.
AMBER instrument control software
NASA Astrophysics Data System (ADS)
Le Coarer, Etienne P.; Zins, Gerard; Gluck, Laurence; Duvert, Gilles; Driebe, Thomas; Ohnaka, Keiichi; Heininger, Matthias; Connot, Claus; Behrend, Jan; Dugue, Michel; Clausse, Jean Michel; Millour, Florentin
2004-09-01
AMBER (Astronomical Multiple BEam Recombiner) is a 3 aperture interferometric recombiner operating between 1 and 2.5 um, for the Very Large Telescope Interferometer (VLTI). The control software of the instrument, based on the VLT Common Software, has been written to comply with specific features of the AMBER hardware, such as the Infrared detector read out modes or piezo stage drivers, as well as with the very specific operation modes of an interferomtric instrument. In this respect, the AMBER control software was designed to insure that all operations, from the preparation of the observations to the control/command of the instrument during the observations, would be kept as simple as possible for the users and operators, opening the use of an interferometric instrument to the largest community of astronomers. Peculiar attention was given to internal checks and calibration procedures both to evaluate data quality in real time, and improve the successes of long term UV plane coverage observations.
Regardless-of-Speed Superconducting LSM Controlled-Repulsive MAGLEV Vehicle
NASA Technical Reports Server (NTRS)
Yoshida, Kinjiro; Egashira, Tatsuya; Hirai, Ryuichi
1996-01-01
This paper proposes a new repulsive Maglev vehicle which a superconducting linear synchronous motor (LSM) can levitate and propel simultaneously, independently of the vehicle speeds. The combined levitation and propulsion control is carried out by controlling mechanical-load angle and armature-current. Dynamic simulations show successful operations with good ride-quality by using a compact control method proposed here.
An approach to quality and performance control in a computer-assisted clinical chemistry laboratory.
Undrill, P E; Frazer, S C
1979-01-01
A locally developed, computer-based clinical chemistry laboratory system has been in operation since 1970. This utilises a Digital Equipment Co Ltd PDP 12 and an interconnected PDP 8/F computer. Details are presented of the performance and quality control techniques incorporated into the system. Laboratory performance is assessed through analysis of results from fixed-level control sera as well as from cumulative sum methods. At a simple level the presentation may be considered purely indicative, while at a more sophisticated level statistical concepts have been introduced to aid the laboratory controller in decision-making processes. PMID:438340
A modern review of the operative management of chronic pancreatitis.
King, Jonathan C; Abeywardina, Shannon; Farrell, James J; Reber, Howard A; Hines, O Joe
2010-10-01
Chronic pancreatitis is a debilitating disease resulting in pain, intestinal malabsorption, endocrine dysfunction, and poor quality of life (QoL). Our aim was to analyze surgical outcomes for patients with chronic pancreatitis. Data for patients undergoing operations for chronic pancreatitis between 1990 and 2009 were reviewed. Demographics, operative and perioperative data, and survival were catalogued. QoL was determined (Short Form 36 and European Organisation for Research and Treatment of Cancer Quality of Life Questionnaire + PAN-26) and compared with historical controls. The mean age was 51 +/- 2 years, 38 patients were male (53%), the most common indication was pain (71%), the etiology of pancreatitis often was alcohol, and most patients underwent a Whipple procedure (56%). Operative time was 316 +/- 17 minutes and blood loss was 363 +/- 75 mL. There were 34 complications in 30 patients (42%) and one death. QoL surveys were administered for 25 of 55 (45%) surviving patients at a mean follow-up of 72 +/- 16 months. Mean survival was 99 +/- 9 months, whereas 5- and 10-year survival were 86 and 75 per cent. QoL scores were uniformly better than historical controls. Our data demonstrate that operations for chronic pancreatitis can be performed with acceptable morbidity and mortality. Patients have excellent survival and improved QoL compared with historical controls. Surgery is an effective and durable treatment option for patients with chronic pancreatitis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
BENNETT,D.B.; PAQUETTE,D.E.; KLAUS,K.
The BNL water supply system meets all water quality standards and has sufficient pumping and storage capacity to meet current and anticipated future operational demands. Because BNL's water supply is drawn from the shallow Upper Glacial aquifer, BNL's source water is susceptible to contamination. The quality of the water supply is being protected through (1) a comprehensive program of engineered and operational controls of existing aquifer contamination and potential sources of new contamination, (2) groundwater monitoring, and (3) potable water treatment. The BNL Source Water Assessment found that the source water for BNL's Western Well Field (comprised of Supply Wellsmore » 4, 6, and 7) has relatively few threats of contamination and identified potential sources are already being carefully managed. The source water for BNL's Eastern Well Field (comprised of Supply Wells 10, 11, and 12) has a moderate number of threats to water quality, primarily from several existing volatile organic compound and tritium plumes. The g-2 Tritium Plume and portions of the Operable Unit III VOC plume fall within the delineated source water area for the Eastern Well Field. In addition, portions of the much slower migrating strontium-90 plumes associated with the Brookhaven Graphite Research Reactor, Waste Concentration Facility and Building 650 lie within the Eastern source water area. However, the rate of travel in the aquifer for strontium-90 is about one-twentieth of that for tritium and volatile organic compounds. The Laboratory has been carefully monitoring plume migration, and has made adjustments to water supply operations. Although a number of BNL's water supply wells were impacted by VOC contamination in the late 1980s, recent routine analysis of water samples from BNL's supply wells indicate that no drinking water standards have been reached or exceeded. The high quality of the water supply strongly indicates that the operational and engineered controls implemented over the past ten years have effectively protected the quality of the water supply.« less
Application Research of Quality Control Technology of Asphalt Pavement based on GPS Intelligent
NASA Astrophysics Data System (ADS)
Wang, Min; Gao, Bo; Shang, Fei; Wang, Tao
2017-10-01
Due to the difficulty of steel deck pavement asphalt layer compaction caused by the effect of the flexible supporting system (orthotropic steel deck plate), it is usually hard and difficult to control for the site compactness to reach the design goal. The intelligent compaction technology is based on GPS control technology and real-time acquisition of actual compaction tracks, and then forms a cloud maps of compaction times, which guide the roller operator to do the compaction in accordance with the design requirement to ensure the deck compaction technology and compaction quality. From the actual construction situation of actual bridge and checked data, the intelligent compaction technology is significant in guaranteeing the steel deck asphalt pavement compactness and quality stability.
ERIC Educational Resources Information Center
Best, Richard A.
An introductory description of the use of centrifuges in the process of volume reduction is provided in this lesson. Three basic centrifuges, their theory of operation, quality of cake and centrate, and operational control testing are discussed. The lesson includes an instructor's guide and student workbook. The instructor's guide contains a…
33 CFR 159.317 - Sampling and reporting.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Sampling and reporting. 159.317... Operations § 159.317 Sampling and reporting. (a) The owner, operator, master or other person in charge of a.../Quality Control Plan (QA/QCP) accepted by the COTP for sampling and analysis of treated sewage and/or...
33 CFR 159.317 - Sampling and reporting.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Sampling and reporting. 159.317... Operations § 159.317 Sampling and reporting. (a) The owner, operator, master or other person in charge of a.../Quality Control Plan (QA/QCP) accepted by the COTP for sampling and analysis of treated sewage and/or...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-29
...: EPA is approving revisions to the Puerto Rico Regulations for the Control of Atmospheric Pollution, submitted to EPA by the Puerto Rico Environmental Quality Board on July 13, 2011. This action approves... of Puerto Rico's Title V Operating Program. Generally the revisions to the regulations involve...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-29
..., published on March 22, 2012, that approved revisions to the Puerto Rico Regulations for the Control of Atmospheric Pollution. Those revisions were submitted to EPA by the Puerto Rico Environmental Quality Board on...] Approval and Promulgation of Implementation Plans and Operating Permits Program; Commonwealth of Puerto...
ERIC Educational Resources Information Center
Rupp, André A.
2018-01-01
This article discusses critical methodological design decisions for collecting, interpreting, and synthesizing empirical evidence during the design, deployment, and operational quality-control phases for automated scoring systems. The discussion is inspired by work on operational large-scale systems for automated essay scoring but many of the…
NASA Technical Reports Server (NTRS)
1989-01-01
Requirements are presented for shuttle system definition; performance and design characteristics; shuttle vehicle end item performance and design characteristics; ground operations complex performance and design characteristics; operability and system design and construction standards; and quality control.
Code of Federal Regulations, 2010 CFR
2010-04-01
... MANUFACTURING PRACTICE IN MANUFACTURING, PACKAGING, LABELING, OR HOLDING OPERATIONS FOR DIETARY SUPPLEMENTS... that adulterates or may lead to adulteration of the component, dietary supplement, or packaging, or... or batches of a dietary supplement; or (5) A dietary supplement is returned. (b)(1) When there is a...
Effect of Personnel Quality on the Performance of Patriot Air Defense System Operators,
1992-01-01
comparable officer-enlisted pair operates a similar facil- ity that controls the activities of three to six batteries. At battery level, the enlisted...them in relation to prescribed rules of engagement. 2Automatic in this context means that the computer identifies an aircraft as friendly, hostile, or
Classification Trees for Quality Control Processes in Automated Constructed Response Scoring.
ERIC Educational Resources Information Center
Williamson, David M.; Hone, Anne S.; Miller, Susan; Bejar, Isaac I.
As the automated scoring of constructed responses reaches operational status, the issue of monitoring the scoring process becomes a primary concern, particularly when the goal is to have automated scoring operate completely unassisted by humans. Using a vignette from the Architectural Registration Examination and data for 326 cases with both human…
The purpose of this SOP is to establish a uniform format for the preparation of SOPs. Use of these protocols ensures consistent implementation of project tasks, documents the preparation and implementation of the procedures used, describes quality control measures and the limits...
40 CFR 63.8075 - What reports must I submit and when?
Code of Federal Regulations, 2010 CFR
2010-07-01
... demonstrations to verify that control devices subject to § 63.8000(d)(3) are operating as designed. (3) A... procedures and quality assurance procedures. (iii) Descriptions of monitoring devices, monitoring frequencies...) Identification of the CMS. (J) The date of the latest CMS certification or audit. (K) The operating day or...
A Machine Vision Quality Control System for Industrial Acrylic Fibre Production
NASA Astrophysics Data System (ADS)
Heleno, Paulo; Davies, Roger; Correia, Bento A. Brázio; Dinis, João
2002-12-01
This paper describes the implementation of INFIBRA, a machine vision system used in the quality control of acrylic fibre production. The system was developed by INETI under a contract with a leading industrial manufacturer of acrylic fibres. It monitors several parameters of the acrylic production process. This paper presents, after a brief overview of the system, a detailed description of the machine vision algorithms developed to perform the inspection tasks unique to this system. Some of the results of online operation are also presented.
Elango, Nithya; Kasi, Vallikkannu; Vembhu, Bhuvaneswari; Poornima, Jeyanthi Govindasamy
2013-09-11
We assessed indoor air quality in photocopier centers and investigated whether occupational exposure to emissions from photocopiers is associated with decline in lung function or changes in haematological parameters, oxidative stress and inflammatory status. Indoor air quality was monitored in five photocopier centers. Pulmonary function was assessed by spirometry in 81 photocopier operators (64 male and 17 female) and 43 healthy control (31 male and 12 female) subjects. Hematological status, serum thio-barbituric acid reactive substances (TBARS), total ferric reducing antioxidant capacity (FRAC), leukotriene B4 (LTB4), 8-isoprostane, C reactive protein (CRP), interleukin 8 (IL-8), clara cell protein (CC-16), intercellular adhesion molecule 1 (ICAM-1) and eosinophilic cationic protein (ECP) were analyzed. Relationships between cumulative exposure, lung function and inflammatory markers were assessed. PM10 and PM2.5 were above the permissible levels in all the photocopier centers, whereas the levels of carbon monoxide, nitrogen oxides, ozone, sulphur dioxide, lead, arsenic, nickel, ammonia, benzene and benzo(a)pyrene were within Indian ambient air quality standards. Lung function was similar in the photocopier operators and control subjects. Serum TBARS was significantly higher and FRAC was lower among photocopier operators when compared to healthy controls. Plasma IL-8, LTB4, ICAM-1 and ECP were significantly higher in the photocopier exposed group. Photocopiers emit high levels of particulate matter. Long term exposure to emissions from photocopiers was not associated with decreased lung function, but resulted in high oxidative stress and systemic inflammation leading to high risk of cardiovascular diseases.
2013-01-01
Background We assessed indoor air quality in photocopier centers and investigated whether occupational exposure to emissions from photocopiers is associated with decline in lung function or changes in haematological parameters, oxidative stress and inflammatory status. Methods Indoor air quality was monitored in five photocopier centers. Pulmonary function was assessed by spirometry in 81 photocopier operators (64 male and 17 female) and 43 healthy control (31 male and 12 female) subjects. Hematological status, serum thio-barbituric acid reactive substances (TBARS), total ferric reducing antioxidant capacity (FRAC), leukotriene B4 (LTB4), 8-isoprostane, C reactive protein (CRP), interleukin 8 (IL-8), clara cell protein (CC-16), intercellular adhesion molecule 1 (ICAM-1) and eosinophilic cationic protein (ECP) were analyzed. Relationships between cumulative exposure, lung function and inflammatory markers were assessed. Results PM10 and PM2.5 were above the permissible levels in all the photocopier centers, whereas the levels of carbon monoxide, nitrogen oxides, ozone, sulphur dioxide, lead, arsenic, nickel, ammonia, benzene and benzo(a)pyrene were within Indian ambient air quality standards. Lung function was similar in the photocopier operators and control subjects. Serum TBARS was significantly higher and FRAC was lower among photocopier operators when compared to healthy controls. Plasma IL-8, LTB4, ICAM-1 and ECP were significantly higher in the photocopier exposed group. Conclusions Photocopiers emit high levels of particulate matter. Long term exposure to emissions from photocopiers was not associated with decreased lung function, but resulted in high oxidative stress and systemic inflammation leading to high risk of cardiovascular diseases. PMID:24025094
Dong, Ling; Sun, Yu; Pei, Wen-Xuan; Dai, Jun-Dong; Wang, Zi-Yu; Pan, Meng; Chen, Jiang-Peng; Wang, Yun
2017-12-01
The concept of "Quality by design" indicates that good design for the whole life cycle of pharmaceutical production enables the drug to meet the expected quality requirements. Aiming at the existing problems of the traditional Chinese medicine (TCM) industry, the TCM standardization system was put forward in this paper from the national strategic level, under the guidance by the idea of quality control in international manufacturing industry and with considerations of TCM industry's own characteristics and development status. The connotation of this strategy was to establish five interrelated systems: multi-indicators system based on tri-indicators system, quality standard and specification system of TCM herbal materials and decoction pieces, quality traceability system, data monitoring system based on whole-process quality control, and whole-process quality management system of TCM, and achieve the whole process systematic and scientific study in TCM industry through "top-level design-implement in steps-system integration" workflow. This article analyzed the correlation between the quality standards of all links, established standard operating procedures of each link and whole process, and constructed a high standard overall quality management system for TCM industry chains, in order to provide a demonstration for the establishment of TCM whole-process quality control system and provide systematic reference and basis for standardization strategy in TCM industry. Copyright© by the Chinese Pharmaceutical Association.
Theoretical linear approach to the combined man-manipulator system in manual control of an aircraft
NASA Technical Reports Server (NTRS)
Brauser, K.
1981-01-01
An approach to the calculation of the dynamic characteristics of the combined man manipulator system in manual aircraft control was derived from a model of the neuromuscular system. This model combines the neuromuscular properties of man with the physical properties of the manipulator system which is introduced as pilot manipulator model into the manual aircraft control. The assumption of man as a quasilinear and time invariant control operator adapted to operating states, depending on the flight phases, of the control system gives rise to interesting solutions of the frequency domain transfer functions of both the man manipulator system and the closed loop pilot aircraft control system. It is shown that it is necessary to introduce the complete precision pilot manipulator model into the closed loop pilot aircraft transfer function in order to understand the well known handling quality criteria, and to derive these criteria directly from human operator properties.
A real-time control framework for urban water reservoirs operation
NASA Astrophysics Data System (ADS)
Galelli, S.; Goedbloed, A.; Schwanenberg, D.
2012-04-01
Drinking water demand in urban areas is growing parallel to the worldwide urban population, and it is acquiring an increasing part of the total water consumption. Since the delivery of sufficient water volumes in urban areas represents a difficult logistic and economical problem, different metropolitan areas are evaluating the opportunity of constructing relatively small reservoirs within urban areas. Singapore, for example, is developing the so-called 'Four National Taps Strategies', which detects the maximization of water yields from local, urban catchments as one of the most important water sources. However, the peculiar location of these reservoirs can provide a certain advantage from the logistical point of view, but it can pose serious difficulties in their daily management. Urban catchments are indeed characterized by large impervious areas: this results in a change of the hydrological cycle, with decreased infiltration and groundwater recharge, and increased patterns of surface and river discharges, with higher peak flows, volumes and concentration time. Moreover, the high concentrations of nutrients and sediments characterizing urban discharges can cause further water quality problems. In this critical hydrological context, the effective operation of urban water reservoirs must rely on real-time control techniques, which can exploit hydro-meteorological information available in real-time from hydrological and nowcasting models. This work proposes a novel framework for the real-time control of combined water quality and quantity objectives in urban reservoirs. The core of this framework is a non-linear Model Predictive Control (MPC) scheme, which employs the current state of the system, the future discharges furnished by a predictive model and a further model describing the internal dynamics of the controlled sub-system to determine an optimal control sequence over a finite prediction horizon. The main advantage of this scheme stands in its reduced computational requests and the capability of exploiting real-time hydro-meteorological information, which are crucial for an effective operation of these fast-varying hydrological systems. The framework is here demonstrated on the operation of Marina Reservoir (Singapore), whose recent construction in late 2008 increased the effective catchment area to about 50% of the total available. Its operation, which accounts for drinking water supply, flash floods control and water quality standards, is here designed by combining the MPC scheme with the process-based hydrological model SOBEK. Extensive simulation experiments show the validity of the proposed framework.
Real-time quality assurance testing using photonic techniques: Application to iodine water system
NASA Technical Reports Server (NTRS)
Arendale, W. F.; Hatcher, Richard; Garlington, Yadilett; Harwell, Jack; Everett, Tracey
1990-01-01
A feasibility study of the use of inspection systems incorporating photonic sensors and multivariate analyses to provide an instrumentation system that in real-time assures quality and that the system in control has been conducted. A system is in control when the near future of the product quality is predictable. Off-line chemical analyses can be used for a chemical process when slow kinetics allows time to take a sample to the laboratory and the system provides a recovery mechanism that returns the system to statistical control without intervention of the operator. The objective for this study has been the implementation of do-it-right-the-first-time and just-in-time philosophies. The Environment Control and Life Support Systems (ECLSS) water reclamation system that adds iodine for biocidal control is an ideal candidate for the study and implementation of do-it-right-the-first-time technologies.
Evaluation of active control technology for short haul aircraft. [cost effectiveness
NASA Technical Reports Server (NTRS)
Renshaw, J. H.; Bennett, J. A.; Harris, O. C.; Honrath, J. F.; Patterson, R. W.
1975-01-01
An evaluation of the economics of short-haul aircraft designed with active controls technology and low wing-loading to achieve short field performance with good ride quality is presented. Results indicate that for such a system incorporating gust load alleviation and augmented stability the direct operating cost is better than for aircraft without active controls.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-15
... Lightering Operations. Since there will be no new VOC controls for point sources, non-point source sector... equivalent to 1.52 x 1.74 = 2.64 tpd NO X reduction shortfall. Delaware has implemented numerous controls... achieved ``as expeditious as practicable.'' Control measures under RACT constitute a major group of RACM...
NASA Astrophysics Data System (ADS)
Keene, Samuel T.; Cerussi, Albert E.; Warren, Robert V.; Hill, Brian; Roblyer, Darren; Leproux, AnaÑ--s.; Durkin, Amanda F.; O'Sullivan, Thomas D.; Haghany, Hosain; Mantulin, William W.; Tromberg, Bruce J.
2013-03-01
Instrument equivalence and quality control are critical elements of multi-center clinical trials. We currently have five identical Diffuse Optical Spectroscopic Imaging (DOSI) instruments enrolled in the American College of Radiology Imaging Network (ACRIN, #6691) trial located at five academic clinical research sites in the US. The goal of the study is to predict the response of breast tumors to neoadjuvant chemotherapy in 60 patients. In order to reliably compare DOSI measurements across different instruments, operators and sites, we must be confident that the data quality is comparable. We require objective and reliable methods for identifying, correcting, and rejecting low quality data. To achieve this goal, we developed and tested an automated quality control algorithm that rejects data points below the instrument noise floor, improves tissue optical property recovery, and outputs a detailed data quality report. Using a new protocol for obtaining dark-noise data, we applied the algorithm to ACRIN patient data and successfully improved the quality of recovered physiological data in some cases.
Brooks, Robin; Thorpe, Richard; Wilson, John
2004-11-11
A new mathematical treatment of alarms that considers them as multi-variable interactions between process variables has provided the first-ever method to calculate values for alarm limits. This has resulted in substantial reductions in false alarms and hence in alarm annunciation rates in field trials. It has also unified alarm management, process control and product quality control into a single mathematical framework so that operations improvement and hence economic benefits are obtained at the same time as increased process safety. Additionally, an algorithm has been developed that advises what changes should be made to Manipulable process variables to clear an alarm. The multi-variable Best Operating Zone at the heart of the method is derived from existing historical data using equation-free methods. It does not require a first-principles process model or an expensive series of process identification experiments. Integral with the method is a new format Process Operator Display that uses only existing variables to fully describe the multi-variable operating space. This combination of features makes it an affordable and maintainable solution for small plants and single items of equipment as well as for the largest plants. In many cases, it also provides the justification for the investments about to be made or already made in process historian systems. Field Trials have been and are being conducted at IneosChlor and Mallinckrodt Chemicals, both in the UK, of the new geometric process control (GPC) method for improving the quality of both process operations and product by providing Process Alarms and Alerts of much high quality than ever before. The paper describes the methods used, including a simple visual method for Alarm Rationalisation that quickly delivers large sets of Consistent Alarm Limits, and the extension to full Alert Management with highlights from the Field Trials to indicate the overall effectiveness of the method in practice.
Control rod calibration and reactivity effects at the IPEN/MB-01 reactor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pinto, Letícia Negrão; Gonnelli, Eduardo; Santos, Adimir dos
2014-11-11
Researches that aim to improve the performance of neutron transport codes and quality of nuclear cross section databases are very important to increase the accuracy of simulations and the quality of the analysis and prediction of phenomena in the nuclear field. In this context, relevant experimental data such as reactivity worth measurements are needed. Control rods may be made of several neutron absorbing materials that are used to adjust the reactivity of the core. For the reactor operation, these experimental data are also extremely important: with them it is possible to estimate the reactivity worth by the movement of themore » control rod, understand the reactor response at each rod position and to operate the reactor safely. This work presents a temperature correction approach for the control rod calibration problem. It is shown the control rod calibration data of the IPEN/MB-01 reactor, the integral and differential reactivity curves and a theoretical analysis, performed by the MCNP-5 reactor physics code, developed and maintained by Los Alamos National Laboratory, using the ENDF/B-VII.0 nuclear data library.« less
Statistical process control applied to mechanized peanut sowing as a function of soil texture.
Zerbato, Cristiano; Furlani, Carlos Eduardo Angeli; Ormond, Antonio Tassio Santana; Gírio, Lucas Augusto da Silva; Carneiro, Franciele Morlin; da Silva, Rouverson Pereira
2017-01-01
The successful establishment of agricultural crops depends on sowing quality, machinery performance, soil type and conditions, among other factors. This study evaluates the operational quality of mechanized peanut sowing in three soil types (sand, silt, and clay) with variable moisture contents. The experiment was conducted in three locations in the state of São Paulo, Brazil. The track-sampling scheme was used for 80 sampling locations of each soil type. Descriptive statistics and statistical process control (SPC) were used to evaluate the quality indicators of mechanized peanut sowing. The variables had normal distributions and were stable from the viewpoint of SPC. The best performance for peanut sowing density, normal spacing, and the initial seedling growing stand was found for clayey soil followed by sandy soil and then silty soil. Sandy or clayey soils displayed similar results regarding sowing depth, which was deeper than in the silty soil. Overall, the texture and the moisture of clayey soil provided the best operational performance for mechanized peanut sowing.
Statistical process control applied to mechanized peanut sowing as a function of soil texture
Furlani, Carlos Eduardo Angeli; da Silva, Rouverson Pereira
2017-01-01
The successful establishment of agricultural crops depends on sowing quality, machinery performance, soil type and conditions, among other factors. This study evaluates the operational quality of mechanized peanut sowing in three soil types (sand, silt, and clay) with variable moisture contents. The experiment was conducted in three locations in the state of São Paulo, Brazil. The track-sampling scheme was used for 80 sampling locations of each soil type. Descriptive statistics and statistical process control (SPC) were used to evaluate the quality indicators of mechanized peanut sowing. The variables had normal distributions and were stable from the viewpoint of SPC. The best performance for peanut sowing density, normal spacing, and the initial seedling growing stand was found for clayey soil followed by sandy soil and then silty soil. Sandy or clayey soils displayed similar results regarding sowing depth, which was deeper than in the silty soil. Overall, the texture and the moisture of clayey soil provided the best operational performance for mechanized peanut sowing. PMID:28742095
A Look at Handling Qualities of Canard Configurations
NASA Technical Reports Server (NTRS)
Anderson, Seth B.
1986-01-01
The first human-powered flight was achieved by a canard-configured aircraft (Wright Brothers). Although other canard concepts were flown with varying degrees of success over the years, the tail-aft configuration has dominated the aircraft market for both military and civil use. Reviewed are the development of several canard aircraft with emphasis on stability and control, handling qualities, and operating problems. The results show that early canard concepts suffered adversely in flight behavior because of a lack of understanding of the sensitivities of these concepts to basic stability and control principles. Modern canard designs have been made competitive with tail-aft configurations by using appropriate handling qualities design criteria.
Quality control of EUVE databases
NASA Technical Reports Server (NTRS)
John, L. M.; Drake, J.
1992-01-01
The publicly accessible databases for the Extreme Ultraviolet Explorer include: the EUVE Archive mailserver; the CEA ftp site; the EUVE Guest Observer Mailserver; and the Astronomical Data System node. The EUVE Performance Assurance team is responsible for verifying that these public EUVE databases are working properly, and that the public availability of EUVE data contained therein does not infringe any data rights which may have been assigned. In this poster, we describe the Quality Assurance (QA) procedures we have developed from the approach of QA as a service organization, thus reflecting the overall EUVE philosophy of Quality Assurance integrated into normal operating procedures, rather than imposed as an external, post facto, control mechanism.
Flying qualities and control system characteristics for superaugmented aircraft
NASA Technical Reports Server (NTRS)
Myers, T. T.; Mcruer, D. T.; Johnston, D. E.
1984-01-01
Aircraft-alone dynamics and superaugmented control system fundamental regulatory properties including stability and regulatory responses of the basic closed-loop systems; fundamental high and low frequency margins and governing factors; and sensitivity to aircraft and controller parameters are addressed. Alternative FCS mechanizations, and mechanizational side effects are also discussed. An overview of flying qualities considerations encompasses general pilot operations as a controller in unattended, intermittent and trim, and full-attention regulatory or command control; effective vehicle primary and secondary response properties to pilot inputs and disturbances; pilot control architectural possibilities; and comparison of superaugmented and conventional aircraft path responses for different forms of pilot control. Results of a simple experimental investigation into pilot dynamic behavior in attitude control of superaugmented aircraft configurations with high frequency time laps and time delays are presented.
Manufacture and quality control of interconnecting wire hardnesses, Volume 1
NASA Technical Reports Server (NTRS)
1972-01-01
A standard is presented for manufacture, installation, and quality control of eight types of interconnecting wire harnesses. The processes, process controls, and inspection and test requirements reflected are based on acknowledgment of harness design requirements, acknowledgment of harness installation requirements, identification of the various parts, materials, etc., utilized in harness manufacture, and formulation of a typical manufacturing flow diagram for identification of each manufacturing and quality control process, operation, inspection, and test. The document covers interconnecting wire harnesses defined in the design standard, including type 1, enclosed in fluorocarbon elastomer convolute, tubing; type 2, enclosed in TFE convolute tubing lines with fiberglass braid; type 3, enclosed in TFE convolute tubing; and type 5, combination of types 3 and 4. Knowledge gained through experience on the Saturn 5 program coupled with recent advances in techniques, materials, and processes was incorporated.
1992-10-01
System Model for Water Quality Control by Jackson K. Brown ...................................... 119 Management Technique for Long-Term Flow... Modeling Activities for the ARCS Program by David C. Cowgill ...................................... 141 Toxicity and Chemistry Testing of Great Lakes...225 Combined Hydrodynamic and Water Quality Modeling of Lower Green Bay by David J. Mark, Barry W. Bunch, and Norman W. Scheffner
Microbial ecology laboratory procedures manual NASA/MSFC
NASA Technical Reports Server (NTRS)
Huff, Timothy L.
1990-01-01
An essential part of the efficient operation of any microbiology laboratory involved in sample analysis is a standard procedures manual. The purpose of this manual is to provide concise and well defined instructions on routine technical procedures involving sample analysis and methods for monitoring and maintaining quality control within the laboratory. Of equal importance is the safe operation of the laboratory. This manual outlines detailed procedures to be followed in the microbial ecology laboratory to assure safety, analytical control, and validity of results.
Study of the time and effort signal in cutting operations
NASA Astrophysics Data System (ADS)
Grosset, E.; Maillard, A.; Bouhelier, C.; Gasnier, J.
1990-02-01
Perception and treatment of an effort signal by computer methods is discussed. An automatic control system used to measure the wear of machine tools and carry out quality control throughout the cutting process is described. The testing system is used to evaluate the performance of tools which have been vacuum plated. The system is used as part of the BRITE study, the goal of which is to develop an expert system for measuring the wear of tools used during drilling and perforation operations.
Nuclear Technology. Course 30: Mechanical Inspection. Module 30-1, Pump Inspection.
ERIC Educational Resources Information Center
Wasil, Ed; Espy, John
This first in a series of eight modules for a course titled Mechanical Inspection describes the type of pumps used in nuclear power plant systems, the basic operating principles of each type, and the inspection activities performed by the quality assurance/quality control technician. The module follows a typical format that includes the following…
Analysis of mental workload of electrical power plant operators of control and operation centers.
Vitório, Daiana Martins; Masculo, Francisco Soares; Melo, Miguel O B C
2012-01-01
Electrical systems can be categorized as critical systems where failure can result in significant financial loss, injury or threats to human life. The operators of the electric power control centers perform an activity in a specialized environment and have to carry it out by mobilizing knowledge and reasoning to which they have adequate training under the terms of the existing rules. To reach this there is a common mental request of personnel involved in these centers due the need to maintain attention, memory and reasoning request. In this sense, this study aims to evaluate the Mental Workload of technical workers of the Control Centers of Electrical Energy. It was undertaken a research on operators control centers of the electricity sector in Northeast Brazil. It was used for systematic observations, followed by interview and application of the instrument National Aeronautics and Space Administration Task Load Index known as NASA-TLX. As a result there will be subsidies for an assessment of mental workload of operators, and a contribution to improving the processes of managing the operation of electric utilities and the quality of workers.
Onerup, Aron; Angenete, Eva; Bock, David; Börjesson, Mats; Fagevik Olsén, Monika; Grybäck Gillheimer, Elin; Skullman, Stefan; Thörn, Sven-Egron; Haglind, Eva; Nilsson, Hanna
2017-05-08
Surgery for colorectal cancer is associated with a high risk of post-operative adverse events, re-operations and a prolonged post-operative recovery. Previously, the effect of prehabilitation (pre-operative physical activity) has been studied for different types of surgery, including colorectal surgery. However, the trials on colorectal surgery have been of limited methodological quality and size. The aim of this trial is to compare the effect of a combined pre- and post-operative intervention of moderate aerobic physical activity and inspiratory muscle training (IMT) with standard care on post-operative recovery after surgery for colorectal cancer. We are conducting a randomised, controlled, parallel-group, open-label, multi-centre trial with physical recovery within 4 weeks after cancer surgery as the primary endpoint. Some 640 patients planned for surgery for colorectal cancer will be enrolled. The intervention consists of pre- and post-operative physical activity with increased daily aerobic activity of moderate intensity as well as IMT. In the control group, patients will be advised to continue their normal daily exercise routine. The primary outcome is patient-reported physical recovery 4 weeks post-operatively. Secondary outcomes are length of sick leave, complication rate and severity, length of hospital stay, re-admittances, re-operations, post-operative mental recovery, quality of life and mortality, as well as changes in insulin-like growth factor 1 and insulin-like growth factor-binding protein 3, perception of pain and a health economic analysis. An increase in moderate-intensity aerobic physical activity is a safe, cheap and feasible intervention that would be possible to implement in standard care for patients with colorectal cancer. If shown to be effective, this lifestyle intervention could be a clinical parallel to pre-operative smoke cessation that has already been implemented with good clinical results. ClinicalTrials.gov identifier: NCT02299596 . Registered on 17 November 2014.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lewis, Michael G.
This quality assurance project plan describes the technical requirements and quality assurance activities of the environmental data collection/analyses operations to close Central Facilities Area Sewage treatment Plant Lagoon 3 and the land application area. It describes the organization and persons involved, the data quality objectives, the analytical procedures, and the specific quality control measures to be employed. All quality assurance project plan activities are implemented to determine whether the results of the sampling and monitoring performed are of the right type, quantity, and quality to satisfy the requirements for closing Lagoon 3 and the land application area.
Addendum: Development of a preprototype times wastewater recovery subsystem
NASA Technical Reports Server (NTRS)
Dehner, G. F.
1984-01-01
The results of the second generation operational improvements and the TIMES (Thermoelectric Integrated Membrane Evaporation Subsystem) 2 study are covered. Areas covered in the second generation operational improvements are improved temperature control, water quality improvements, subsytem operational improvements, solid handling improvements, wastewater pretreatment optimization, and membrane rejuvenation concepts. The task for the TIMES 2 study are thermoelectric regenerator improvement, recycle loop pH operational criteria, recycle loop component optimization, and hollow fiber membrane evaporator improvement. Results are presented and conclusions are drawn from both studies.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-10
... following three rules identified under group 4: 1. Rule 4566--Organic Material Composting Operations... Volatile Organic Compound Regulations--California Department of Pesticide Regulation--submitted August 2... from VOC control requirements, while the CTG for this source category (``Control of Volatile Organic...
30 CFR 905.816 - Performance standards-Surface mining activities.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Quality Control Act, Cal. Pub. Res. Code section 13000 et seq.; the California Water Code section 1200 et seq.; the California Air Pollution Control Laws, Cal. Health & Safety Code section 39000 et seq.; the..., DEPARTMENT OF THE INTERIOR PROGRAMS FOR THE CONDUCT OF SURFACE MINING OPERATIONS WITHIN EACH STATE CALIFORNIA...
30 CFR 905.817 - Performance standards-Underground mining activities.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Quality Control Act, Cal. Pub. Res. Code section 13000 et seq.; the California Water Code section 1200 et seq.; the California Air Pollution Control Laws, Cal. Health & Safety Code section 39000 et seq.; the..., DEPARTMENT OF THE INTERIOR PROGRAMS FOR THE CONDUCT OF SURFACE MINING OPERATIONS WITHIN EACH STATE CALIFORNIA...
30 CFR 905.817 - Performance standards-Underground mining activities.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Quality Control Act, Cal. Pub. Res. Code section 13000 et seq.; the California Water Code section 1200 et seq.; the California Air Pollution Control Laws, Cal. Health & Safety Code section 39000 et seq.; the..., DEPARTMENT OF THE INTERIOR PROGRAMS FOR THE CONDUCT OF SURFACE MINING OPERATIONS WITHIN EACH STATE CALIFORNIA...
30 CFR 905.816 - Performance standards-Surface mining activities.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Quality Control Act, Cal. Pub. Res. Code section 13000 et seq.; the California Water Code section 1200 et seq.; the California Air Pollution Control Laws, Cal. Health & Safety Code section 39000 et seq.; the..., DEPARTMENT OF THE INTERIOR PROGRAMS FOR THE CONDUCT OF SURFACE MINING OPERATIONS WITHIN EACH STATE CALIFORNIA...
30 CFR 905.816 - Performance standards-Surface mining activities.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Quality Control Act, Cal. Pub. Res. Code section 13000 et seq.; the California Water Code section 1200 et seq.; the California Air Pollution Control Laws, Cal. Health & Safety Code section 39000 et seq.; the..., DEPARTMENT OF THE INTERIOR PROGRAMS FOR THE CONDUCT OF SURFACE MINING OPERATIONS WITHIN EACH STATE CALIFORNIA...
30 CFR 905.817 - Performance standards-Underground mining activities.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Quality Control Act, Cal. Pub. Res. Code section 13000 et seq.; the California Water Code section 1200 et seq.; the California Air Pollution Control Laws, Cal. Health & Safety Code section 39000 et seq.; the..., DEPARTMENT OF THE INTERIOR PROGRAMS FOR THE CONDUCT OF SURFACE MINING OPERATIONS WITHIN EACH STATE CALIFORNIA...
30 CFR 905.816 - Performance standards-Surface mining activities.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Quality Control Act, Cal. Pub. Res. Code section 13000 et seq.; the California Water Code section 1200 et seq.; the California Air Pollution Control Laws, Cal. Health & Safety Code section 39000 et seq.; the..., DEPARTMENT OF THE INTERIOR PROGRAMS FOR THE CONDUCT OF SURFACE MINING OPERATIONS WITHIN EACH STATE CALIFORNIA...
30 CFR 905.817 - Peformance standards-Underground mining activities.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Quality Control Act, Cal. Pub. Res. Code section 13000 et seq.; the California Water Code section 1200 et seq.; the California Air Pollution Control Laws, Cal. Health & Safety Code section 39000 et seq.; the..., DEPARTMENT OF THE INTERIOR PROGRAMS FOR THE CONDUCT OF SURFACE MINING OPERATIONS WITHIN EACH STATE CALIFORNIA...
49 CFR 1182.2 - Content of applications.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Mexico or owned or controlled by persons of that country, copies of the actual operating authorities must... the quality of the human environment and the conservation of energy resources; (7) Information to... transaction is either domiciled in Mexico or owned or controlled by persons of that country; and (11) If the...
49 CFR 1182.2 - Content of applications.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Mexico or owned or controlled by persons of that country, copies of the actual operating authorities must... the quality of the human environment and the conservation of energy resources; (7) Information to... transaction is either domiciled in Mexico or owned or controlled by persons of that country; and (11) If the...
10 CFR 74.59 - Quality assurance and accounting requirements.
Code of Federal Regulations, 2012 CFR
2012-01-01
... analyses and evaluations of the design, installation, preoperational tests, calibration, and operation of... performed at a pre-determined frequency, indicate a need for recalibration. Calibrations and tests must be... necessary for performance of the material control tests required by § 74.53(b). (e) Measurement control. The...
10 CFR 74.59 - Quality assurance and accounting requirements.
Code of Federal Regulations, 2011 CFR
2011-01-01
... analyses and evaluations of the design, installation, preoperational tests, calibration, and operation of... performed at a pre-determined frequency, indicate a need for recalibration. Calibrations and tests must be... necessary for performance of the material control tests required by § 74.53(b). (e) Measurement control. The...
25 CFR 216.4 - Technical examination of prospective surface exploration and mining operations.
Code of Federal Regulations, 2010 CFR
2010-04-01
... ecological values; and control of erosion, flooding, and pollution of water; the isolation of toxic materials; the prevention of air pollution; the reclamation by revegetation, replacement of soil or by other... quality below standards established by the appropriate State water pollution control agency, or by the...
43 CFR 23.5 - Technical examination of prospective surface exploration and mining operations.
Code of Federal Regulations, 2010 CFR
2010-10-01
...; the control of erosion, flooding, and pollution of water; the isolation of toxic materials; the prevention of air pollution; the reclamation by revegetation, replacement of soil, or by other means, of... lowering of water quality below standards established by the appropriate State water pollution control...
Internal quality control: planning and implementation strategies.
Westgard, James O
2003-11-01
The first essential in setting up internal quality control (IQC) of a test procedure in the clinical laboratory is to select the proper IQC procedure to implement, i.e. choosing the statistical criteria or control rules, and the number of control measurements, according to the quality required for the test and the observed performance of the method. Then the right IQC procedure must be properly implemented. This review focuses on strategies for planning and implementing IQC procedures in order to improve the quality of the IQC. A quantitative planning process is described that can be implemented with graphical tools such as power function or critical-error graphs and charts of operating specifications. Finally, a total QC strategy is formulated to minimize cost and maximize quality. A general strategy for IQC implementation is recommended that employs a three-stage design in which the first stage provides high error detection, the second stage low false rejection and the third stage prescribes the length of the analytical run, making use of an algorithm involving the average of normal patients' data.
NASA Astrophysics Data System (ADS)
Cassagnole, Manon; Ramos, Maria-Helena; Thirel, Guillaume; Gailhard, Joël; Garçon, Rémy
2017-04-01
The improvement of a forecasting system and the evaluation of the quality of its forecasts are recurrent steps in operational practice. However, the evaluation of forecast value or forecast usefulness for better decision-making is, to our knowledge, less frequent, even if it might be essential in many sectors such as hydropower and flood warning. In the hydropower sector, forecast value can be quantified by the economic gain obtained with the optimization of operations or reservoir management rules. Several hydropower operational systems use medium-range forecasts (up to 7-10 days ahead) and energy price predictions to optimize hydropower production. Hence, the operation of hydropower systems, including the management of water in reservoirs, is impacted by weather, climate and hydrologic variability as well as extreme events. In order to assess how the quality of hydrometeorological forecasts impact operations, it is essential to first understand if and how operations and management rules are sensitive to input predictions of different quality. This study investigates how 7-day ahead deterministic and ensemble streamflow forecasts of different quality might impact the economic gains of energy production. It is based on a research model developed by Irstea and EDF to investigate issues relevant to the links between quality and value of forecasts in the optimisation of energy production at the short range. Based on streamflow forecasts and pre-defined management constraints, the model defines the best hours (i.e., the hours with high energy prices) to produce electricity. To highlight the link between forecasts quality and their economic value, we built several synthetic ensemble forecasts based on observed streamflow time series. These inputs are generated in a controlled environment in order to obtain forecasts of different quality in terms of accuracy and reliability. These forecasts are used to assess the sensitivity of the decision model to forecast quality. Relationships between forecast quality and economic value are discussed. This work is part of the IMPREX project, a research project supported by the European Commission under the Horizon 2020 Framework programme, with grant No. 641811 (http://www.imprex.eu)
Quality assurance and control issues for HF radar wave and current measurements
NASA Astrophysics Data System (ADS)
Wyatt, Lucy
2015-04-01
HF radars are now widely used to provide surface current measurements over wide areas of the coastal ocean for scientific and operational applications. In general data quality is acceptable for these applications but there remain issues that impact on the quantity and quality of the data. These include problems with calibration and interference which impact on both phased array (e.g. WERA, Pisces) and direction-finding (e.g. SeaSonde) radars. These same issues and others (e.g. signal-to-noise, in-cell current variability, antenna sidelobes) also impact on the quality and quantity of wave data that can be obtained. These issues will be discussed in this paper, illustrated with examples from deployments of WERA, Pisces and SeaSonde radars in the UK, Europe, USA and Australia. These issues involve both quality assurance (making sure the radars perform to spec and the software is fully operational) and in quality control (identifying problems with the data due to radar hardware or software performance issues and flagging these in the provided data streams). Recommendations for the former, and current practice (of the author and within the Australian Coastal Ocean Radar Network, ACORN*) for the latter, will be discussed. The quality control processes for wave measurement are not yet as well developed as those for currents and data from some deployments can be rather noisy. Some new methods, currently under development by SeaView Sensing Ltd and being tested with ACORN data, will be described and results presented. *ACORN is a facility of the Australian Integrated Marine Observing System, IMOS. IMOS is a national collaborative research infrastructure, supported by Australian Government. It is led by University of Tasmania in partnership with the Australian marine and climate science community.
Generating Options for Active Risk Control (GO-ARC): introducing a novel technique.
Card, Alan J; Ward, James R; Clarkson, P John
2014-01-01
After investing significant amounts of time and money in conducting formal risk assessments, such as root cause analysis (RCA) or failure mode and effects analysis (FMEA), healthcare workers are left to their own devices in generating high-quality risk control options. They often experience difficulty in doing so, and tend toward an overreliance on administrative controls (the weakest category in the hierarchy of risk controls). This has important implications for patient safety and the cost effectiveness of risk management operations. This paper describes a before and after pilot study of the Generating Options for Active Risk Control (GO-ARC) technique, a novel tool to improve the quality of the risk control options generation process. The quantity, quality (using the three-tiered hierarchy of risk controls), variety, and novelty of risk controls generated. Use of the GO-ARC technique was associated with improvement on all measures. While this pilot study has some notable limitations, it appears that the GO-ARC technique improved the risk control options generation process. Further research is needed to confirm this finding. It is also important to note that improved risk control options are a necessary, but not sufficient, step toward the implementation of more robust risk controls. © 2013 National Association for Healthcare Quality.
36 CFR 228.112 - Compliance and inspection.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Forest officer shall give prompt written notice to an operator whenever reclamation of a portion of the... and State water quality standards, including the requirements of the Federal Water Pollution Control...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-06
... ovens used in wet-laid non-woven fiber mat manufacturing operations when nitrogen containing resins or other additives are used. These two actions affect NOx sources operating in the Dallas Fort-Worth (DFW... include low-temperature drying ovens and curing ovens used in wet-laid, non-woven fiber mat manufacturing...
The purpose of this SOP is to establish a uniform format for the preparation of SOPs. Use of these protocols ensures consistent implementation of project tasks, documents the preparation and implementation of the procedures used, describes quality control measures and the limits...
Code of Federal Regulations, 2010 CFR
2010-10-01
..., distribution, cost, and use; (2) Flood control; (3) Navigation; (4) Water supply; (5) Air quality; and (6..., including: (1) Any evidence on the implementation costs or operational impacts for electricity production of...) Cost significantly less to implement; or (ii) Result in improved operation of the project works for...
Use of artificial intelligence in the production of high quality minced meat
NASA Astrophysics Data System (ADS)
Kapovsky, B. R.; Pchelkina, V. A.; Plyasheshnik, P. I.; Dydykin, A. S.; Lazarev, A. A.
2017-09-01
A design for an automatic line for minced meat production according to new production technology based on an innovative meat milling method is proposed. This method allows the necessary degree of raw material comminution at the stage of raw material preparation to be obtained, which leads to production intensification due to the traditional meat mass comminution equipment being unnecessary. To ensure consistent quality of the product obtained, the use of on-line automatic control of the technological process for minced meat production is envisaged. This system has been developed using artificial intelligence methods and technologies. The system is trainable during the operation process, adapts to changes in processed raw material characteristics and to external impacts that affect the system operation, and manufactures meat shavings with minimal dispersion of the typical particle size. The control system includes equipment for express analysis of the chemical composition of the minced meat and its temperature after comminution. In this case, the minced meat production process can be controlled strictly as a function of time, which excludes subjective factors for assessing the degree of finished product readiness. This will allow finished meat products with consistent, targeted high quality to be produced.
Automated stent defect detection and classification with a high numerical aperture optical system
NASA Astrophysics Data System (ADS)
Bermudez, Carlos; Laguarta, Ferran; Cadevall, Cristina; Matilla, Aitor; Ibañez, Sergi; Artigas, Roger
2017-06-01
Stent quality control is a highly critical process. Cardiovascular stents have to be inspected 100% so as no defective stent is implanted in a human body. However, this visual control is currently performed manually and every stent could need tenths of minutes to be inspected. In this paper, a novel optical inspection system is presented. By the combination of a high numerical aperture (NA) optical system, a rotational stage and a line-scan camera, unrolled sections of the outer and inner surfaces of the stent are obtained and image-processed at high speed. Defects appearing in those surfaces and also in the edges are extremely contrasted due to the shadowing effect of the high NA illumination and acquisition approach. Therefore by means of morphological operations and a sensitivity parameter, defects are detected. Based on a trained defect library, a binary classifier sorts each kind of defect through a set of scoring vectors, providing the quality operator with all the required information to finally take a decision. We expect this new approach to make defect detection completely objective and to dramatically reduce the time and cost of stent quality control stage.
Zhao-Hui, Zheng; Jun, Qin; Li, Chen; Hong, Zhu; Li, Tang; Zu-Wu, Tu; Ming-Xing, Zeng; Qian, Sun; Shun-Xiang, Cai
2016-10-09
To analyze the construction and operation status of management system of laboratories of schistosomiasis control institutions in Hubei Province, so as to provide the reference for the standardized detection and management of schistosomiasis laboratories. According to the laboratory standard of schistosomiasis at provincial, municipal and county levels, the management system construction and operation status of 60 schistosomiasis control institutions was assessed by the acceptance examination method from 2013 to 2015. The management system was already occupied over all the laboratories of schistosomiasis control institutions and was officially running. There were 588 non-conformities and the inconsistency rate was 19.60%. The non-conformity rate of the management system of laboratory quality control was 38.10% (224 cases) and the non-conformity rate of requirements of instrument and equipment was 23.81% (140 cases). The management system has played an important role in the standardized management of schistosomiasis laboratories.
A CPS Based Optimal Operational Control System for Fused Magnesium Furnace
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chai, Tian-you; Wu, Zhi-wei; Wang, Hong
Fused magnesia smelting for fused magnesium furnace (FMF) is an energy intensive process with high temperature and comprehensive complexities. Its operational index namely energy consumption per ton (ECPT) is defined as the consumed electrical energy per ton of acceptable quality and is difficult to measure online. Moreover, the dynamics of ECPT cannot be precisely modelled mathematically. The model parameters of the three-phase currents of the electrodes such as the molten pool level, its variation rate and resistance are uncertain and nonlinear functions of the changes in both the smelting process and the raw materials composition. In this paper, an integratedmore » optimal operational control algorithm proposed is composed of a current set-point control, a current switching control and a self-optimized tuning mechanism. The tight conjoining of and coordination between the computational resources including the integrated optimal operational control, embedded software, industrial cloud, wireless communication and the physical resources of FMF constitutes a cyber-physical system (CPS) based embedded optimal operational control system. Successful application of this system has been made for a production line with ten fused magnesium furnaces in a factory in China, leading to a significant reduced ECPT.« less
Comparative evaluation of two asthma care quality measures among Medicaid beneficiaries.
Samnaliev, Mihail; Baxter, Jeffrey D; Clark, Robin E
2009-05-01
The relative performance of asthma care quality measures has not been evaluated in Medicaid populations. Using complete claims and pharmaceutical data for 19,076 patients with persistent asthma (based on Health Effectiveness and Data Information Set criteria) in five Medicaid populations, we compared the following two measures of asthma care quality: filling prescriptions for controller asthma medications within 1 year and the ratio of controller medication to the total number of asthma medication prescriptions filled within 1 year. We calculated whether meeting each quality measure was associated with decreased odds of emergency department (ED) treatment episodes. We then compared the odds ratios, receiver operating characteristic (ROC) curves, and deviances between models, using each measure to predict ED utilization in Medicaid populations. Although meeting each measure was associated with lower odds of ED utilization, this decrease was larger if the controller asthma medication measure was met rather than the ratio measure. Additionally, models using the controller medication measure had greater areas under the ROC curve and smaller deviances than models using the ratio measure. Both administrative measures of asthma care quality were associated with lower odds of ED utilization. The controller medication measure of asthma care quality may be better than the ratio measure in relation to emergency asthma care utilization by Medicaid beneficiaries.
King, Heather C; Spence, Dennis L; Hickey, Anita H; Sargent, Paul; Elesh, Ronald; Connelly, Cynthia D
2015-05-01
The purpose of this study was to examine the feasibility and acceptability of an auricular acupuncture (AA) insomnia regimen among Operation Iraqi Freedom and Operation Enduring Freedom veterans with post-traumatic stress disorder and sleep disturbance. Secondarily, this study examined the effect of an AA insomnia regimen on objective sleep times by wrist actigraphy, subjective sleep times by sleep diary, and sleep quality ratings utilizing the Pittsburg Sleep Quality Index. Veterans (n = 30) were randomized to receive a 3-week AA insomnia regimen. Veterans receiving the AA insomnia regimen reported it as a more acceptable treatment for sleep disturbance than subjects in the control group (AA group median = 5 vs. control group median = 3, p = 0.004). Significant differences between groups were found on the sleep quality and daytime dysfunction components of the Pittsburgh Sleep Quality Index (p = 0.003, p = 0.004). No other significant differences between groups were found for objective and subjective sleep measures. These results suggest that an AA insomnia regimen may improve sleep quality and daytime dysfunction among veterans with post-traumatic stress disorder. Future, large-scale, prospective clinical trials are needed to examine AA effects on sleep. Reprint & Copyright © 2015 Association of Military Surgeons of the U.S.
[Quality management in cardiovascular echography].
Gullace, Giuseppe
2002-12-01
The quality management of an organization can be defined as the ability to identify, plan and implement programs of measure, analysis, verification and control that allow to monitor management, resources, activities, processes and output/outcome of the same organization, including the satisfaction of the customers. Whatever the model used, it is demonstrated that the management-quality system, either for professional quality or for organization, turns out to be effective even in the health organizations within and to any level of organizational-structural complexity. The present paper concerns the experience of the Italian Society of Cardiovascular Echography (SIEC) on quality certification, both as a scientific society compared to other health organizations and to cardiovascular echo laboratories, and the definition of minimum requirements for the accreditation of the same laboratories. The model most frequently used for quality management is represented by the ISO 9000: Vision 2000, that is a management model with specific reference to the organization and the customer satisfaction. The model applied to the health structure needs a rapid change in mentality that addresses the operators to define, share and achieve objectives to be brought on by means of an active collaboration, group activity and deep sense of belonging necessary to the attainment of expected objectives. When the model is applied by a scientific society, it is necessary to take into account the different structural and functional organization, the constitution and the operators differing on the point of view of origin, experiences, mentality, and roles. The ISO 9000: Vision 2000 model can be applied also to the cardiovascular echo laboratory which may be compared to a simple organization; for its corrected functioning, SIEC has defined minimal requirements for the accreditation, realization and modalities to carry out and manage quality. The quality system represents a new way of operating of an organization that enhances capability and performance of the operators, stimulates their creativity and facilitates the activities of all, to guarantee both the quality of the product and the satisfaction of operators and customers at the same time.
Flores-Alsina, Xavier; Arnell, Magnus; Amerlinck, Youri; Corominas, Lluís; Gernaey, Krist V; Guo, Lisha; Lindblom, Erik; Nopens, Ingmar; Porro, Jose; Shaw, Andy; Snip, Laura; Vanrolleghem, Peter A; Jeppsson, Ulf
2014-01-01
The objective of this paper was to show the potential additional insight that result from adding greenhouse gas (GHG) emissions to plant performance evaluation criteria, such as effluent quality (EQI) and operational cost (OCI) indices, when evaluating (plant-wide) control/operational strategies in wastewater treatment plants (WWTPs). The proposed GHG evaluation is based on a set of comprehensive dynamic models that estimate the most significant potential on-site and off-site sources of CO₂, CH₄ and N₂O. The study calculates and discusses the changes in EQI, OCI and the emission of GHGs as a consequence of varying the following four process variables: (i) the set point of aeration control in the activated sludge section; (ii) the removal efficiency of total suspended solids (TSS) in the primary clarifier; (iii) the temperature in the anaerobic digester; and (iv) the control of the flow of anaerobic digester supernatants coming from sludge treatment. Based upon the assumptions built into the model structures, simulation results highlight the potential undesirable effects of increased GHG production when carrying out local energy optimization of the aeration system in the activated sludge section and energy recovery from the AD. Although off-site CO₂ emissions may decrease, the effect is counterbalanced by increased N₂O emissions, especially since N₂O has a 300-fold stronger greenhouse effect than CO₂. The reported results emphasize the importance and usefulness of using multiple evaluation criteria to compare and evaluate (plant-wide) control strategies in a WWTP for more informed operational decision making. © 2013.
NASA Astrophysics Data System (ADS)
Kota, Venkata Reddy; Vinnakoti, Sudheer
2017-12-01
Today, maintaining Power Quality (PQ) is very important in the growing competent world. With new equipments and devices, new challenges are also being put before power system operators. Unified Power Quality Conditioner (UPQC) is proposed to mitigate many power quality problems and to improve the performance of the power system. In this paper, an UPQC with Fuzzy Logic controller for capacitor voltage balancing is proposed in Synchronous Reference Frame (SRF) based control with Modified Phased Locked Loop (MPLL). The proposed controller with SRF-MPLL based control is tested under non-linear and unbalanced load conditions. The system is developed in Matlab/Simulink and its performance is analyzed under various conditions like non-linear, unbalanced load and polluted supply voltage including voltage sag/swells. Active and reactive power flow in the system, power factor and %THD of voltages and currents before and after compensation are also analyzed in this work. Results prove the applicability of the proposed scheme for power quality improvement. It is observed that the fuzzy controller gives better performance than PI controller with faster capacitor voltage balancing and also improves the dynamic performance of the system.
Sedlack, Jeffrey D
2010-01-01
Surgeons have been slow to incorporate industrial reliability techniques. Process control methods were applied to surgeon waiting time between cases, and to length of stay (LOS) after colon surgery. Waiting times between surgeries were evaluated by auditing the operating room records of a single hospital over a 1-month period. The medical records of 628 patients undergoing colon surgery over a 5-year period were reviewed. The average surgeon wait time between cases was 53 min, and the busiest surgeon spent 291/2 hr in 1 month waiting between surgeries. Process control charting demonstrated poor overall control of the room turnover process. Average LOS after colon resection also demonstrated very poor control. Mean LOS was 10 days. Weibull's conditional analysis revealed a conditional LOS of 9.83 days. Serious process management problems were identified in both analyses. These process issues are both expensive and adversely affect the quality of service offered by the institution. Process control mechanisms were suggested or implemented to improve these surgical processes. Industrial reliability and quality management tools can easily and effectively identify process control problems that occur on surgical services. © 2010 National Association for Healthcare Quality.
222-S Laboratory Quality Assurance Plan. Revision 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meznarich, H.K.
1995-07-31
This Quality Assurance Plan provides,quality assurance (QA) guidance, regulatory QA requirements (e.g., 10 CFR 830.120), and quality control (QC) specifications for analytical service. This document follows the U.S Department of Energy (DOE) issued Hanford Analytical Services Quality Assurance Plan (HASQAP). In addition, this document meets the objectives of the Quality Assurance Program provided in the WHC-CM-4-2, Section 2.1. Quality assurance elements required in the Guidelines and Specifications for Preparing Quality Assurance Program Plans (QAMS-004) and Interim Guidelines and Specifications for Preparing Quality Assurance Project Plans (QAMS-005) from the US Environmental Protection Agency (EPA) are covered throughout this document. A qualitymore » assurance index is provided in the Appendix A. This document also provides and/or identifies the procedural information that governs laboratory operations. The personnel of the 222-S Laboratory and the Standards Laboratory including managers, analysts, QA/QC staff, auditors, and support staff shall use this document as guidance and instructions for their operational and quality assurance activities. Other organizations that conduct activities described in this document for the 222-S Laboratory shall follow this QA/QC document.« less
Process performance and product quality in an integrated continuous antibody production process.
Karst, Daniel J; Steinebach, Fabian; Soos, Miroslav; Morbidelli, Massimo
2017-02-01
Continuous manufacturing is currently being seriously considered in the biopharmaceutical industry as the possible new paradigm for producing therapeutic proteins, due to production cost and product quality related benefits. In this study, a monoclonal antibody producing CHO cell line was cultured in perfusion mode and connected to a continuous affinity capture step. The reliable and stable integration of the two systems was enabled by suitable control loops, regulating the continuous volumetric flow and adapting the operating conditions of the capture process. For the latter, an at-line HPLC measurement of the harvest concentration subsequent to the bioreactor was combined with a mechanistic model of the capture chromatographic unit. Thereby, optimal buffer consumption and productivity throughout the process was realized while always maintaining a yield above the target value of 99%. Stable operation was achieved at three consecutive viable cell density set points (20, 60, and 40 × 10 6 cells/mL), together with consistent product quality in terms of aggregates, fragments, charge isoforms, and N-linked glycosylation. In addition, different values for these product quality attributes such as N-linked glycosylation, charge variants, and aggregate content were measured at the different steady states. As expected, the amount of released DNA and HCP was significantly reduced by the capture step for all considered upstream operating conditions. This study is exemplary for the potential of enhancing product quality control and modulation by integrated continuous manufacturing. Biotechnol. Bioeng. 2017;114: 298-307. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
Sliwa, S. M.
1980-01-01
Direct constrained parameter optimization was used to optimally size a medium range transport for minimum direct operating cost. Several stability and control constraints were varied to study the sensitivity of the configuration to specifying the unaugmented flying qualities of transports designed to take maximum advantage of relaxed static stability augmentation systems. Additionally, a number of handling qualities related design constants were studied with respect to their impact on the design.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McHenry, Mark P.; Johnson, Jay; Hightower, Mike
The increasing pressure for network operators to meet distribution network power quality standards with increasing peak loads, renewable energy targets, and advances in automated distributed power electronics and communications is forcing policy-makers to understand new means to distribute costs and benefits within electricity markets. Discussions surrounding how distributed generation (DG) exhibits active voltage regulation and power factor/reactive power control and other power quality capabilities are complicated by uncertainties of baseline local distribution network power quality and to whom and how costs and benefits of improved electricity infrastructure will be allocated. DG providing ancillary services that dynamically respond to the networkmore » characteristics could lead to major network improvements. With proper market structures renewable energy systems could greatly improve power quality on distribution systems with nearly no additional cost to the grid operators. Renewable DG does have variability challenges, though this issue can be overcome with energy storage, forecasting, and advanced inverter functionality. This paper presents real data from a large-scale grid-connected PV array with large-scale storage and explores effective mitigation measures for PV system variability. As a result, we discuss useful inverter technical knowledge for policy-makers to mitigate ongoing inflation of electricity network tariff components by new DG interconnection requirements or electricity markets which value power quality and control.« less
McHenry, Mark P.; Johnson, Jay; Hightower, Mike
2016-01-01
The increasing pressure for network operators to meet distribution network power quality standards with increasing peak loads, renewable energy targets, and advances in automated distributed power electronics and communications is forcing policy-makers to understand new means to distribute costs and benefits within electricity markets. Discussions surrounding how distributed generation (DG) exhibits active voltage regulation and power factor/reactive power control and other power quality capabilities are complicated by uncertainties of baseline local distribution network power quality and to whom and how costs and benefits of improved electricity infrastructure will be allocated. DG providing ancillary services that dynamically respond to the networkmore » characteristics could lead to major network improvements. With proper market structures renewable energy systems could greatly improve power quality on distribution systems with nearly no additional cost to the grid operators. Renewable DG does have variability challenges, though this issue can be overcome with energy storage, forecasting, and advanced inverter functionality. This paper presents real data from a large-scale grid-connected PV array with large-scale storage and explores effective mitigation measures for PV system variability. As a result, we discuss useful inverter technical knowledge for policy-makers to mitigate ongoing inflation of electricity network tariff components by new DG interconnection requirements or electricity markets which value power quality and control.« less
Matthes, Wilbur J.; Sholar, Clyde J.; George, John R.
1992-01-01
This report describes procedures used by the Iowa District sediment laboratory of the U.S. Geological Survey to assure the quality of sediment-laboratory data. These procedures can be used by other U.S. Geological Survey laboratories regardless of size and type of operation for quality assurance and quality control of specific sediment-laboratory processes. Also described are the equipment, specifications, calibration and maintenance, and the protocol for methods used in the analyses of fluvial sediment for concentration or particle size.
Operator agency in process intervention: tampering versus application of tacit knowledge
NASA Astrophysics Data System (ADS)
Van Gestel, P.; Pons, D. J.; Pulakanam, V.
2015-09-01
Statistical process control (SPC) theory takes a negative view of adjustment of process settings, which is termed tampering. In contrast, quality and lean programmes actively encourage operators to acts of intervention and personal agency in the improvement of production outcomes. This creates a conflict that requires operator judgement: How does one differentiate between unnecessary tampering and needful intervention? Also, difficult is that operators apply tacit knowledge to such judgements. There is a need to determine where in a given production process the operators are applying tacit knowledge, and whether this is hindering or aiding quality outcomes. The work involved the conjoint application of systems engineering, statistics, and knowledge management principles, in the context of a case study. Systems engineering was used to create a functional model of a real plant. Actual plant data were analysed with the statistical methods of ANOVA, feature selection, and link analysis. This identified the variables to which the output quality was most sensitive. These key variables were mapped back to the functional model. Fieldwork was then directed to those areas to prospect for operator judgement activities. A natural conversational approach was used to determine where and how operators were applying judgement. This contrasts to the interrogative approach of conventional knowledge management. Data are presented for a case study of a meat rendering plant. The results identify specific areas where operators' tacit knowledge and mental model contribute to quality outcomes and untangles the motivations behind their agency. Also evident is how novice and expert operators apply their knowledge differently. Novices were focussed on meeting throughput objectives, and their incomplete understanding of the plant characteristics led them to inadvertently sacrifice quality in the pursuit of productivity in certain situations. Operators' responses to the plant are affected by their individual mental models of the plant, which differ between operators and have variable validity. Their behaviour is also affected by differing interpretations of how their personal agency should be applied to the achievement of production objectives. The methodology developed here is an integration of systems engineering, statistical analysis, and knowledge management. It shows how to determine where in a given production process the operator intervention is occurring, how it affects quality outcomes, and what tacit knowledge operators are using. It thereby assists the continuous quality improvement processes in a different way to SPC. A second contribution is the provision of a novel methodology for knowledge management, one that circumvents the usual codification barriers to knowledge management.
Control of the TSU 2-m automatic telescope
NASA Astrophysics Data System (ADS)
Eaton, Joel A.; Williamson, Michael H.
2004-09-01
Tennessee State University is operating a 2-m automatic telescope for high-dispersion spectroscopy. The alt-azimuth telescope is fiber-coupled to a conventional echelle spectrograph with two resolutions (R=30,000 and 70,000). We control this instrument with four computers running linux and communicating over ethernet through the UDP protocol. A computer physically located on the telescope handles the acquisition and tracking of stars. We avoid the need for real-time programming in this application by periodically latching the positions of the axes in a commercial motion controller and the time in a GPS receiver. A second (spectrograph) computer sets up the spectrograph and runs its CCD, a third (roof) computer controls the roll-off roof and front flap of the telescope enclosure, and the fourth (executive) computer makes decisions about which stars to observe and when to close the observatory for bad weather. The only human intervention in the telescope's operation involves changing the observing program, copying data back to TSU, and running quality-control checks on the data. It has been running reliably in this completely automatic, unattended mode for more than a year with all day-to-day adminsitration carried out over the Internet. To support automatic operation, we have written a number of useful tools to predict and analyze what the telescope does. These include a simulator that predicts roughly how the telescope will operate on a given night, a quality-control program to parse logfiles from the telescope and identify problems, and a rescheduling program that calculates new priorities to keep the frequency of observation for the various stars roughly as desired. We have also set up a database to keep track of the tens of thousands of spectra we expect to get each year.
NASA Astrophysics Data System (ADS)
Smits, K. M.; Drumheller, Z. W.; Lee, J. H.; Illangasekare, T. H.; Regnery, J.; Kitanidis, P. K.
2015-12-01
Aquifers around the world show troubling signs of irreversible depletion and seawater intrusion as climate change, population growth, and urbanization lead to reduced natural recharge rates and overuse. Scientists and engineers have begun to revisit the technology of managed aquifer recharge and recovery (MAR) as a means to increase the reliability of the diminishing and increasingly variable groundwater supply. Unfortunately, MAR systems remain wrought with operational challenges related to the quality and quantity of recharged and recovered water stemming from a lack of data-driven, real-time control. This research seeks to develop and validate a general simulation-based control optimization algorithm that relies on real-time data collected though embedded sensors that can be used to ease the operational challenges of MAR facilities. Experiments to validate the control algorithm were conducted at the laboratory scale in a two-dimensional synthetic aquifer under both homogeneous and heterogeneous packing configurations. The synthetic aquifer used well characterized technical sands and the electrical conductivity signal of an inorganic conservative tracer as a surrogate measure for water quality. The synthetic aquifer was outfitted with an array of sensors and an autonomous pumping system. Experimental results verified the feasibility of the approach and suggested that the system can improve the operation of MAR facilities. The dynamic parameter inversion reduced the average error between the simulated and observed pressures between 12.5 and 71.4%. The control optimization algorithm ran smoothly and generated optimal control decisions. Overall, results suggest that with some improvements to the inversion and interpolation algorithms, which can be further advanced through testing with laboratory experiments using sensors, the concept can successfully improve the operation of MAR facilities.
2013-01-01
Introduction The ability of standard operating procedures to improve pre-hospital critical care by changing pre-hospital physician behaviour is uncertain. We report data from a prospective quality control study of the effect on pre-hospital critical care anaesthesiologists’ behaviour of implementing a standard operating procedure for pre-hospital controlled ventilation. Materials and methods Anaesthesiologists from eight pre-hospital critical care teams in the Central Denmark Region prospectively registered pre-hospital advanced airway-management data according to the Utstein-style template. We collected pre-intervention data from February 1st 2011 to January 31st 2012, implemented the standard operating procedure on February 1st 2012 and collected post intervention data from February 1st 2012 until October 31st 2012. We included transported patients of all ages in need of controlled ventilation treated with pre-hospital endotracheal intubation or the insertion of a supraglottic airways device. The objective was to evaluate whether the development and implementation of a standard operating procedure for controlled ventilation during transport could change pre-hospital critical care anaesthesiologists’ behaviour and thereby increase the use of automated ventilators in these patients. Results The implementation of a standard operating procedure increased the overall prevalence of automated ventilator use in transported patients in need of controlled ventilation from 0.40 (0.34-0.47) to 0.74 (0.69-0.80) with a prevalence ratio of 1.85 (1.57-2.19) (p = 0.00). The prevalence of automated ventilator use in transported traumatic brain injury patients in need of controlled ventilation increased from 0.44 (0.26-0.62) to 0.85 (0.62-0.97) with a prevalence ratio of 1.94 (1.26-3.0) (p = 0.0039). The prevalence of automated ventilator use in patients transported after return of spontaneous circulation following pre-hospital cardiac arrest increased from 0.39 (0.26-0.48) to 0.69 (0.58-0.78) with a prevalence ratio of 1.79 (1.36-2.35) (p = 0.00). Conclusion We have shown that the implementation of a standard operating procedure for pre-hospital controlled ventilation can significantly change pre-hospital critical care anaesthesiologists’ behaviour. PMID:24308781
The purpose of this SOP is to outline the process of field quality assurance and quality control checks. This procedure was followed to ensure consistent data retrieval during the Arizona NHEXAS project and the Border study. Keywords: custody; QA/QC; field checks.
The U.S.-Mex...
Dissecting the Molecular Mechanism of RhoC GTPase Expression in the Normal and Malignant Breast
2009-09-01
Department of Defense, Washington Headquarters Services , Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway...different genes (chimera candidates), (iii) nonmapping, (iv) mitochondrial, (v) quality con- trol, or (vi) ribosomal (Table S1). Overall, the chimera...fileswereparsedtocategorizepassingfiltermatepairsas (i)mappingtothesame transcript, (ii) ribosomal, (iii) mitochondrial, (iv) quality control, (v) chimera can- didates, and (vi
Impacts of flare emissions from an ethylene plant shutdown to regional air quality
NASA Astrophysics Data System (ADS)
Wang, Ziyuan; Wang, Sujing; Xu, Qiang; Ho, Thomas
2016-08-01
Critical operations of chemical process industry (CPI) plants such as ethylene plant shutdowns could emit a huge amount of VOCs and NOx, which may result in localized and transient ozone pollution events. In this paper, a general methodology for studying dynamic ozone impacts associated with flare emissions from ethylene plant shutdowns has been developed. This multi-scale simulation study integrates process knowledge of plant shutdown emissions in terms of flow rate and speciation together with regional air-quality modeling to quantitatively investigate the sensitivity of ground-level ozone change due to an ethylene plant shutdown. The study shows the maximum hourly ozone increments can vary significantly by different plant locations and temporal factors including background ozone data and solar radiation intensity. It helps provide a cost-effective air-quality control strategy for industries by choosing the optimal starting time of plant shutdown operations in terms of minimizing the induced ozone impact (reduced from 34.1 ppb to 1.2 ppb in the performed case studies). This study provides valuable technical supports for both CPI and environmental policy makers on cost-effective air-quality controls in the future.
NASA Technical Reports Server (NTRS)
Robinson, Michael; Steiner, Matthias; Wolff, David B.; Ferrier, Brad S.; Kessinger, Cathy; Einaudi, Franco (Technical Monitor)
2000-01-01
The primary function of the TRMM Ground Validation (GV) Program is to create GV rainfall products that provide basic validation of satellite-derived precipitation measurements for select primary sites. A fundamental and extremely important step in creating high-quality GV products is radar data quality control. Quality control (QC) processing of TRMM GV radar data is based on some automated procedures, but the current QC algorithm is not fully operational and requires significant human interaction to assure satisfactory results. Moreover, the TRMM GV QC algorithm, even with continuous manual tuning, still can not completely remove all types of spurious echoes. In an attempt to improve the current operational radar data QC procedures of the TRMM GV effort, an intercomparison of several QC algorithms has been conducted. This presentation will demonstrate how various radar data QC algorithms affect accumulated radar rainfall products. In all, six different QC algorithms will be applied to two months of WSR-88D radar data from Melbourne, Florida. Daily, five-day, and monthly accumulated radar rainfall maps will be produced for each quality-controlled data set. The QC algorithms will be evaluated and compared based on their ability to remove spurious echoes without removing significant precipitation. Strengths and weaknesses of each algorithm will be assessed based on, their abilit to mitigate both erroneous additions and reductions in rainfall accumulation from spurious echo contamination and true precipitation removal, respectively. Contamination from individual spurious echo categories will be quantified to further diagnose the abilities of each radar QC algorithm. Finally, a cost-benefit analysis will be conducted to determine if a more automated QC algorithm is a viable alternative to the current, labor-intensive QC algorithm employed by TRMM GV.
Independent Quality Control Review of EPA OIG Operations
The review considers selected audit work performed by EPA OIG, Office of Audit, Congressional and Public Liaison, Mission Systems, and Program Evaluation, during the period for 1 October 2006 through 30 September 2007 .
40 CFR 264.301 - Design and operating requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... other factors which would influence the quality and mobility of the leachate produced and the potential... emission controls or metal casting molding sand, and such wastes do not contain constituents which would...
40 CFR 264.221 - Design and operating requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... ground water or surface water; and (4) All other factors which would influence the quality and mobility... emission controls or metal casting molding sand, and such wastes do not contain constituents which would...
Phase plane analysis: applying chaos theory in health care.
Priesmeyer, H R; Sharp, L F
1995-01-01
This article applies the new science of nonlinearity to administrative issues and accounts receivable management in health care, and it provides a new perspective on common operating and quality control measures.
19 CFR 10.877 - Direct costs of processing operations.
Code of Federal Regulations, 2011 CFR
2011-04-01
..., supervisory, quality control, and similar personnel; (2) Tools, dies, molds, and other indirect materials, and... are not limited to: (1) Profit; and (2) General expenses of doing business that are either not...
19 CFR 10.814 - Direct costs of processing operations.
Code of Federal Regulations, 2010 CFR
2010-04-01
..., supervisory, quality control, and similar personnel; (2) Tools, dies, molds, and other indirect materials, and... are not limited to: (1) Profit; and (2) General expenses of doing business that are either not...
19 CFR 10.774 - Direct costs of processing operations.
Code of Federal Regulations, 2011 CFR
2011-04-01
..., supervisory, quality control, and similar personnel; (2) Tools, dies, molds, and other indirect materials, and... are not limited to: (1) Profit; and (2) General expenses of doing business that are either not...
19 CFR 10.814 - Direct costs of processing operations.
Code of Federal Regulations, 2011 CFR
2011-04-01
..., supervisory, quality control, and similar personnel; (2) Tools, dies, molds, and other indirect materials, and... are not limited to: (1) Profit; and (2) General expenses of doing business that are either not...
19 CFR 10.774 - Direct costs of processing operations.
Code of Federal Regulations, 2010 CFR
2010-04-01
..., supervisory, quality control, and similar personnel; (2) Tools, dies, molds, and other indirect materials, and... are not limited to: (1) Profit; and (2) General expenses of doing business that are either not...
Manufacturing Research: Self-Directed Control
1991-01-01
reduce this sensitivity. SDO is performing Taguchi’s parameter design . 1-13 Statistical Process Control SPC techniques will be used to monitor the process...Florida,R.E. Krieger Pub. Co., 1988. Dehnad, Khowrow, Quality Control . Robust Design . and the Taguchi Method, Pacific Grove, California, Wadsworth... control system. This turns out to be a non -trivial exercise. A human operator can see an event occur (such as the vessel pressurizing above its setpoint
Engineering for Autonomous Seismic Stations at the IRIS PASSCAL Instrument Center
NASA Astrophysics Data System (ADS)
Anderson, K. R.; Carpenter, P.; Beaudoin, B. C.; Parker, T.; Hebert, J.; Childs, D.; Chung, P.; Reusch, A. M.
2015-12-01
The NSF funded Incorporated Research Institutions for Seismology (IRIS) through New Mexico Tech operates the PASSCAL Instrument Center (PIC) in Socorro New Mexico. The engineering effort at the PIC seeks to optimize seismic station operations for all portable experiments, include those in extremely remote and harsh polar environments. Recent advances have resulted in improved station design, allowing improved operational efficiencies, data quality return and reduction in station logistics associated with installation, maintenance and decommissioning of stations. These include: Battery and power system designs. Incorporating primary Lithium Thionyl Chloride (LTC) technology with rechargeable Lithium Iron Phosphate (LiFePO4) batteries allows systems to operate in areas with long-term solar autonomy (high latitudes). Development includes charge controller systems to switch between primary and secondary technologies efficiently. Enclosures: Engineered solutions to efficiently manage waste heat, maintain operational environment and provide light-weight and durable housing for seismic instrumentation. Communications: In collaboration with Xeos Technologies Inc., we deliver Iridium-based SOH/Command and Control telemetry as well as full bandwidth seismic data communications in high latitude environments at low power requirements. Smaller-lighter-instrumentation: Through the GEOICE MRI, we are working with Nanometrics on next generation "all-in-one" seismic systems that can be deployed in polar environments - easing logistics, minimizing installation time and improving data quality return for these expensive deployments. All autonomous station designs are openly and freely available at the IRIS PASSCAL webpage (www.passcal.nmt.edu/polar/design-drawings). More information on GEOICE and data quality from various seismometer emplacements will be presented in other posters at this AGU meeting.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-04
...EPA is proposing to approve revisions to the Antelope Valley Air Quality Management District (AVAQMD), Eastern Kern Air Pollution Control District (EKAPCD), and Santa Barbara County Air Pollution Control District (SBCAPCD) portions of the California State Implementation Plan (SIP). We are proposing to approve revisions to local rules that define terms used in other air pollution regulations in these areas and a rule rescission that address Petroleum Coke Calcining Operations--Oxides of Sulfur, under the Clean Air Act as amended in 1990 (CAA or the Act).
1998-10-21
The Glenn Research Center (GRC) Telescience Support Center (TSC) is a NASA telescience ground facility that provides the capability to execute ground support operations of on-orbit International Space Station (ISS) and Space Shuttle payloads. This capability is provided with the coordination with the Marshall Space Flight Center (MSFC) Huntsville Operations Support Center (HOSC), the Johnson Space Center (JSC) Mission Control Center in Houston (MCC-H) and other remote ground control facilities. The concept of telescience is a result of NASA's vision to provide worldwide distributed ISS ground operations that will enable payload developers and scientists to control and monitor their on-board payloads from any location -- not necessarily a NASA site. This concept enhances the quality of scientific and technological data while decreasing operation costs of long-term support activities by providing ground operation services to a Principal Investigator and Engineering Team at their home site. The TSC acts as a hub in which users can either locate their operations staff within the walls of the TSC or request the TSC operation capabilities be extended to a location more convenient such as a university.
Automatic-Control System for Safer Brazing
NASA Technical Reports Server (NTRS)
Stein, J. A.; Vanasse, M. A.
1986-01-01
Automatic-control system for radio-frequency (RF) induction brazing of metal tubing reduces probability of operator errors, increases safety, and ensures high-quality brazed joints. Unit combines functions of gas control and electric-power control. Minimizes unnecessary flow of argon gas into work area and prevents electrical shocks from RF terminals. Controller will not allow power to flow from RF generator to brazing head unless work has been firmly attached to head and has actuated micro-switch. Potential shock hazard eliminated. Flow of argon for purging and cooling must be turned on and adjusted before brazing power applied. Provision ensures power not applied prematurely, causing damaged work or poor-quality joints. Controller automatically turns off argon flow at conclusion of brazing so potentially suffocating gas does not accumulate in confined areas.
An Improved Power Quality Based Sheppard-Taylor Converter Fed BLDC Motor Drive
NASA Astrophysics Data System (ADS)
Singh, Bhim; Bist, Vashist
2015-12-01
This paper deals with the design and analysis of a power factor correction based Sheppard-Taylor converter fed brushless dc motor (BLDCM) drive. The speed of the BLDCM is controlled by adjusting the dc link voltage of the voltage source inverter (VSI) feeding BLDCM. Moreover, a low frequency switching of the VSI is used for electronically commutating the BLDCM for reduced switching losses. The Sheppard-Taylor converter is designed to operate in continuous conduction mode to achieve an improved power quality at the ac mains for a wide range of speed control and supply voltage variation. The BLDCM drive is designed and its performance is simulated in a MATLAB/Simulink environment to achieve the power quality indices within the limits of the international power quality standard IEC-61000-3-2.
Verification and Implementation of Operations Safety Controls for Flight Missions
NASA Technical Reports Server (NTRS)
Smalls, James R.; Jones, Cheryl L.; Carrier, Alicia S.
2010-01-01
There are several engineering disciplines, such as reliability, supportability, quality assurance, human factors, risk management, safety, etc. Safety is an extremely important engineering specialty within NASA, and the consequence involving a loss of crew is considered a catastrophic event. Safety is not difficult to achieve when properly integrated at the beginning of each space systems project/start of mission planning. The key is to ensure proper handling of safety verification throughout each flight/mission phase. Today, Safety and Mission Assurance (S&MA) operations engineers continue to conduct these flight product reviews across all open flight products. As such, these reviews help ensure that each mission is accomplished with safety requirements along with controls heavily embedded in applicable flight products. Most importantly, the S&MA operations engineers are required to look for important design and operations controls so that safety is strictly adhered to as well as reflected in the final flight product.
Operational quality control of daily precipitation using spatio-climatological consistency testing
NASA Astrophysics Data System (ADS)
Scherrer, S. C.; Croci-Maspoli, M.; van Geijtenbeek, D.; Naguel, C.; Appenzeller, C.
2010-09-01
Quality control (QC) of meteorological data is of utmost importance for climate related decisions. The search for an effective automated QC of precipitation data has proven difficult and many weather services still use mainly manual inspection of daily precipitation including MeteoSwiss. However, man power limitations force many weather services to move towards less labour intensive and more automated QC with the challenge to keeping data quality high. In the last decade, several approaches have been presented to objectify daily precipitation QC. Here we present a spatio-climatological approach that will be implemented operationally at MeteoSwiss. It combines the information from the event based spatial distribution of everyday's precipitation field and the historical information of the interpolation error using different precipitation intensity intervals. Expert judgement shows that the system is able to detect potential outliers very well (hardly any missed errors) without creating too many false alarms that need human inspection. 50-80% of all flagged values have been classified as real errors by the data editor. This is much better than the roughly 15-20% using standard spatial regression tests. Very helpful in the QC process is the automatic redistribution of accumulated several day sums. Manual inspection in operations can be reduced and the QC of precipitation objectified substantially.
Handling qualities related to stall/spin accidents of supersonic fighter aircraft
NASA Technical Reports Server (NTRS)
Anderson, S. B.
1984-01-01
This paper reviews the handling qualities which influence the high angle of attack (AOA) behavior of supersonic fighter aircraft in order to obtain a clearer understanding of the causes of stall/spin accidents. The results show that, because modern fighters suffer more serious consequences when control is lost, good handling qualities are essential for safe operation at high AOA. Relaxed static stability used on some fighter aircraft can result in control problems at high AOA owing to inertia coupling and the difficulty of a recovery from a deep stall. Indications are that the use of departure/spin resistance and an automatic spin prevention system will greatly improve the safety record for modern supersonic fighters.
A cost-constrained model of strategic service quality emphasis in nursing homes.
Davis, M A; Provan, K G
1996-02-01
This study employed structural equation modeling to test the relationship between three aspects of the environmental context of nursing homes; Medicaid dependence, ownership status, and market demand, and two basic strategic orientations: low cost and differentiation based on service quality emphasis. Hypotheses were proposed and tested against data collected from a sample of nursing homes operating in a single state. Because of the overwhelming importance of cost control in the nursing home industry, a cost constrained strategy perspective was supported. Specifically, while the three contextual variables had no direct effect on service quality emphasis, the entire model was supported when cost control orientation was introduced as a mediating variable.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-13
... wood paneling coating facilities. Sixth, Rule 15A NCAC 02D .0961, ``Offset Lithographic Printing and Letterpress Printing'' was adopted to control VOC emissions from heatset inks, fountain solution and cleaning materials used in offset lithographic printing operations, as well as VOC emissions from heatset inks used...
The Navy’s Quality Journey: Operational Implementation of TQL
1993-04-01
training. Dr. Kaoru Ishikawa "Guide to Ouality Control" "QC begins with education and ends with education. To implement TQC, we need to carry out...York: McGraw-Hill, 1986. 20. Ishikawa , Kaoru . What is Total Qualit Control? Englewood Cliffs, NJ: Prentice-Hall, Inc., 1985. 21. Ishikawa , Kaoru
40 CFR 63.10001 - Affirmative defense for exceedence of emission limit during malfunction.
Code of Federal Regulations, 2013 CFR
2013-07-01
... unavoidable failure of air pollution control and monitoring equipment, process equipment, or a process to..., proper design or better operation and maintenance practices; and (iii) Did not stem from any activity or... ambient air quality, the environment and human health; and (6) All emissions monitoring and control...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-13
... methods and definitions. The most significant problem with the prior version is the definition of... submitted to EPA a new Rule 3745-21-25 ``Control of VOC emissions from reinforced plastic composites... acceptable because Ohio has adopted OAC 3745-21- 25 for Reinforced Plastics Composites Production Operations...
NASA Astrophysics Data System (ADS)
Johnson, Tony; Metcalfe, Jason; Brewster, Benjamin; Manteuffel, Christopher; Jaswa, Matthew; Tierney, Terrance
2010-04-01
The proliferation of intelligent systems in today's military demands increased focus on the optimization of human-robot interactions. Traditional studies in this domain involve large-scale field tests that require humans to operate semiautomated systems under varying conditions within military-relevant scenarios. However, provided that adequate constraints are employed, modeling and simulation can be a cost-effective alternative and supplement. The current presentation discusses a simulation effort that was executed in parallel with a field test with Soldiers operating military vehicles in an environment that represented key elements of the true operational context. In this study, "constructive" human operators were designed to represent average Soldiers executing supervisory control over an intelligent ground system. The constructive Soldiers were simulated performing the same tasks as those performed by real Soldiers during a directly analogous field test. Exercising the models in a high-fidelity virtual environment provided predictive results that represented actual performance in certain aspects, such as situational awareness, but diverged in others. These findings largely reflected the quality of modeling assumptions used to design behaviors and the quality of information available on which to articulate principles of operation. Ultimately, predictive analyses partially supported expectations, with deficiencies explicable via Soldier surveys, experimenter observations, and previously-identified knowledge gaps.
Off-Line Quality Control In Integrated Circuit Fabrication Using Experimental Design
NASA Astrophysics Data System (ADS)
Phadke, M. S.; Kackar, R. N.; Speeney, D. V.; Grieco, M. J.
1987-04-01
Off-line quality control is a systematic method of optimizing production processes and product designs. It is widely used in Japan to produce high quality products at low cost. The method was introduced to us by Professor Genichi Taguchi who is a Deming-award winner and a former Director of the Japanese Academy of Quality. In this paper we will i) describe the off-line quality control method, and ii) document our efforts to optimize the process for forming contact windows in 3.5 Aim CMOS circuits fabricated in the Murray Hill Integrated Circuit Design Capability Laboratory. In the fabrication of integrated circuits it is critically important to produce contact windows of size very near the target dimension. Windows which are too small or too large lead to loss of yield. The off-line quality control method has improved both the process quality and productivity. The variance of the window size has been reduced by a factor of four. Also, processing time for window photolithography has been substantially reduced. The key steps of off-line quality control are: i) Identify important manipulatable process factors and their potential working levels. ii) Perform fractional factorial experiments on the process using orthogonal array designs. iii) Analyze the resulting data to determine the optimum operating levels of the factors. Both the process mean and the process variance are considered in this analysis. iv) Conduct an additional experiment to verify that the new factor levels indeed give an improvement.
Weld analysis and control system
NASA Technical Reports Server (NTRS)
Kennedy, Larry Z. (Inventor); Rodgers, Michael H. (Inventor); Powell, Bradley W. (Inventor); Burroughs, Ivan A. (Inventor); Goode, K. Wayne (Inventor)
1994-01-01
The invention is a Weld Analysis and Control System developed for active weld system control through real time weld data acquisition. Closed-loop control is based on analysis of weld system parameters and weld geometry. The system is adapted for use with automated welding apparatus having a weld controller which is capable of active electronic control of all aspects of a welding operation. Enhanced graphics and data displays are provided for post-weld analysis. The system provides parameter acquisition, including seam location which is acquired for active torch cross-seam positioning. Torch stand-off is also monitored for control. Weld bead and parent surface geometrical parameters are acquired as an indication of weld quality. These parameters include mismatch, peaking, undercut, underfill, crown height, weld width, puddle diameter, and other measurable information about the weld puddle regions, such as puddle symmetry, etc. These parameters provide a basis for active control as well as post-weld quality analysis and verification. Weld system parameters, such as voltage, current and wire feed rate, are also monitored and archived for correlation with quality parameters.
A statistical model for water quality predictions from a river discharge using coastal observations
NASA Astrophysics Data System (ADS)
Kim, S.; Terrill, E. J.
2007-12-01
Understanding and predicting coastal ocean water quality has benefits for reducing human health risks, protecting the environment, and improving local economies which depend on clean beaches. Continuous observations of coastal physical oceanography increase the understanding of the processes which control the fate and transport of a riverine plume which potentially contains high levels of contaminants from the upstream watershed. A data-driven model of the fate and transport of river plume water from the Tijuana River has been developed using surface current observations provided by a network of HF radar operated as part of a local coastal observatory that has been in place since 2002. The model outputs are compared with water quality sampling of shoreline indicator bacteria, and the skill of an alarm for low water quality is evaluated using the receiver operating characteristic (ROC) curve. In addition, statistical analysis of beach closures in comparison with environmental variables is also discussed.
Concern with health effects resulting from PM10 exposure is drawing increased regulatory scrutiny and research toward local agricultural tillage operations. To investigate the control effectiveness of one of the current Conservation Management Practices (CMPs) written for agricul...
Developing a space network interface simulator: The NTS approach
NASA Technical Reports Server (NTRS)
Hendrzak, Gary E.
1993-01-01
This paper describes the approach used to redevelop the Network Control Center (NCC) Test System (NTS), a hardware and software facility designed to make testing of the NCC Data System (NCCDS) software efficient, effective, and as rigorous as possible prior to operational use. The NTS transmits and receives network message traffic in real-time. Data transfer rates and message content are strictly controlled and are identical to that of the operational systems. NTS minimizes the need for costly and time-consuming testing with the actual external entities (e.g., the Hubble Space Telescope (HST) Payload Operations Control Center (POCC) and the White Sands Ground Terminal). Discussed are activities associated with the development of the NTS, lessons learned throughout the project's lifecycle, and resulting productivity and quality increases.
Man-machine interactive imaging and data processing using high-speed digital mass storage
NASA Technical Reports Server (NTRS)
Alsberg, H.; Nathan, R.
1975-01-01
The role of vision in teleoperation has been recognized as an important element in the man-machine control loop. In most applications of remote manipulation, direct vision cannot be used. To overcome this handicap, the human operator's control capabilities are augmented by a television system. This medium provides a practical and useful link between workspace and the control station from which the operator perform his tasks. Human performance deteriorates when the images are degraded as a result of instrumental and transmission limitations. Image enhancement is used to bring out selected qualities in a picture to increase the perception of the observer. A general purpose digital computer, an extensive special purpose software system is used to perform an almost unlimited repertoire of processing operations.
Valkenet, K; Trappenburg, J C A; Hulzebos, E H; van Meeteren, N L U; Backx, F J G
2017-09-01
Pre-operative inspiratory muscle training has been shown to decrease the incidence of postoperative pneumonia and length of hospital stay in patients undergoing coronary artery bypass graft surgery (CABG). This study investigated if this decrease acted as a mediator on the time course of quality of life. Complementary analyses of a published randomised controlled trial. The initial trial included patients awaiting CABG surgery at a Dutch university hospital. The secondary analyses used data from the initial trial for patients who had completed at least one quality-of-life questionnaire. Participants were allocated at random to the intervention group or the usual care group. The intervention group followed a home-based pre-operative inspiratory muscle training programme. Quality of life was measured at five time points. Between-group differences in quality-of-life scores were analysed using mixed linear modelling. The secondary analyses used data for 235 patients. In line with the initial trial, pneumonia and length of hospital stay were decreased significantly in the intervention group. The time courses for all patients showed significant improvements in quality of life after surgery compared with baseline. No significant differences in quality of life were observed over time between the two groups. Despite decreased incidence of pneumonia and length of hospital stay in the intervention group, this study did not find any improvements in quality of life due to the pre-operative home-based inspiratory muscle training programme. Clinical trial registration number ISRCTN17691887. Copyright © 2016 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.
Examining System-Wide Impacts of Solar PV Control Systems with a Power Hardware-in-the-Loop Platform
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, Tess L.; Fuller, Jason C.; Schneider, Kevin P.
2014-10-11
High penetration levels of distributed solar PV power generation can lead to adverse power quality impacts such as excessive voltage rise, voltage flicker, and reactive power values that result in unacceptable voltage levels. Advanced inverter control schemes have been proposed that have the potential to mitigate many power quality concerns. However, closed-loop control may lead to unintended behavior in deployed systems as complex interactions can occur between numerous operating devices. In order to enable the study of the performance of advanced control schemes in a detailed distribution system environment, a Hardware-in-the-Loop (HIL) platform has been developed. In the HIL system,more » GridLAB-D, a distribution system simulation tool, runs in real-time mode at the Pacific Northwest National Laboratory (PNNL) and supplies power system parameters at a point of common coupling to hardware located at the National Renewable Energy Laboratory (NREL). Hardware inverters interact with grid and PV simulators emulating an operational distribution system and power output from the inverters is measured and sent to PNNL to update the real-time distribution system simulation. The platform is described and initial test cases are presented. The platform is used to study the system-wide impacts and the interactions of controls applied to inverters that are integrated into a simulation of the IEEE 8500-node test feeder, with inverters in either constant power factor control or active volt/VAR control. We demonstrate that this HIL platform is well-suited to the study of advanced inverter controls and their impacts on the power quality of a distribution feeder. Additionally, the results from HIL are used to validate GridLAB-D simulations of advanced inverter controls.« less
Control of maglev vehicles with aerodynamic and guideway disturbances
NASA Technical Reports Server (NTRS)
Flueckiger, Karl; Mark, Steve; Caswell, Ruth; Mccallum, Duncan
1994-01-01
A modeling, analysis, and control design methodology is presented for maglev vehicle ride quality performance improvement as measured by the Pepler Index. Ride quality enhancement is considered through active control of secondary suspension elements and active aerodynamic surfaces mounted on the train. To analyze and quantify the benefits of active control, the authors have developed a five degree-of-freedom lumped parameter model suitable for describing a large class of maglev vehicles, including both channel and box-beam guideway configurations. Elements of this modeling capability have been recently employed in studies sponsored by the U.S. Department of Transportation (DOT). A perturbation analysis about an operating point, defined by vehicle and average crosswind velocities, yields a suitable linearized state space model for multivariable control system analysis and synthesis. Neglecting passenger compartment noise, the ride quality as quantified by the Pepler Index is readily computed from the system states. A statistical analysis is performed by modeling the crosswind disturbances and guideway variations as filtered white noise, whereby the Pepler Index is established in closed form through the solution to a matrix Lyapunov equation. Data is presented which indicates the anticipated ride quality achieved through various closed-loop control arrangements.
Quality control process improvement of flexible printed circuit board by FMEA
NASA Astrophysics Data System (ADS)
Krasaephol, Siwaporn; Chutima, Parames
2018-02-01
This research focuses on the quality control process improvement of Flexible Printed Circuit Board (FPCB), centred around model 7-Flex, by using Failure Mode and Effect Analysis (FMEA) method to decrease proportion of defective finished goods that are found at the final inspection process. Due to a number of defective units that were found at the final inspection process, high scraps may be escaped to customers. The problem comes from poor quality control process which is not efficient enough to filter defective products from in-process because there is no In-Process Quality Control (IPQC) or sampling inspection in the process. Therefore, the quality control process has to be improved by setting inspection gates and IPCQs at critical processes in order to filter the defective products. The critical processes are analysed by the FMEA method. IPQC is used for detecting defective products and reducing chances of defective finished goods escaped to the customers. Reducing proportion of defective finished goods also decreases scrap cost because finished goods incur higher scrap cost than work in-process. Moreover, defective products that are found during process can reflect the abnormal processes; therefore, engineers and operators should timely solve the problems. Improved quality control was implemented for 7-Flex production lines from July 2017 to September 2017. The result shows decreasing of the average proportion of defective finished goods and the average of Customer Manufacturers Lot Reject Rate (%LRR of CMs) equal to 4.5% and 4.1% respectively. Furthermore, cost saving of this quality control process equals to 100K Baht.
DoD Veterinary Service Activity Role in DoD Food Safety.
1998-01-01
medical research and development; zoonotic disease prevention and control; and food safety and quality assurance. The latter mission is not all encompassing...within DoD. This paper reviews the division of responsibilities, within DoD, for food safety and quality assurance. The complexity of the division...and the problem it causes joint operations planners are explored. A proposal for integrating overall strategic responsibility for food safety and quality assurance into the DoD Veterinary Service Activity is developed.
Government Contract Law Cases.
1983-10-01
have no power of supervision or control ere the fact otherwise, we would cease to have a popular nment, but instead would be governed by a group of...article. The principal question presented is appellant’s right to repudiate the contract without liability. The operative questions controlling our...and quality control actions. Paragraph 5 of the document read as follows: THE TRAINING, DOCUMENTATION, SOFTWARE, PACKAGING QUOTED WILL BE DGC
Liu, Yanchen; Shi, Hanchang; Shi, Huiming; Wang, Zhiqiang
2010-10-01
The aim of study was proposed a new control model feasible on-line implemented by Programmable Logic Controller (PLC) to enhance nitrogen removal against the fluctuation of influent in Carrousel oxidation ditch. The discrete-time control model was established by confirmation model of operational conditions based on a expert access, which was obtained by a simulation using Activated Sludge Model 2-D (ASM2-D) and Computation Fluid Dynamics (CFD), and discrete-time control model to switch between different operational stages. A full-scale example is provided to demonstrate the feasibility of the proposed operation and the procedure of the control design. The effluent quality was substantially improved, to the extent that it met the new wastewater discharge standards of NH(3)-N<5mg/L and TN<15 mg/L enacted in China throughout a one-day period with fluctuation of influent. Copyright © 2010 Elsevier Ltd. All rights reserved.
Capacity and reliability analyses with applications to power quality
NASA Astrophysics Data System (ADS)
Azam, Mohammad; Tu, Fang; Shlapak, Yuri; Kirubarajan, Thiagalingam; Pattipati, Krishna R.; Karanam, Rajaiah
2001-07-01
The deregulation of energy markets, the ongoing advances in communication networks, the proliferation of intelligent metering and protective power devices, and the standardization of software/hardware interfaces are creating a dramatic shift in the way facilities acquire and utilize information about their power usage. The currently available power management systems gather a vast amount of information in the form of power usage, voltages, currents, and their time-dependent waveforms from a variety of devices (for example, circuit breakers, transformers, energy and power quality meters, protective relays, programmable logic controllers, motor control centers). What is lacking is an information processing and decision support infrastructure to harness this voluminous information into usable operational and management knowledge to handle the health of their equipment and power quality, minimize downtime and outages, and to optimize operations to improve productivity. This paper considers the problem of evaluating the capacity and reliability analyses of power systems with very high availability requirements (e.g., systems providing energy to data centers and communication networks with desired availability of up to 0.9999999). The real-time capacity and margin analysis helps operators to plan for additional loads and to schedule repair/replacement activities. The reliability analysis, based on computationally efficient sum of disjoint products, enables analysts to decide the optimum levels of redundancy, aids operators in prioritizing the maintenance options for a given budget and monitoring the system for capacity margin. The resulting analytical and software tool is demonstrated on a sample data center.
Toro A, Richard; Campos, Claudia; Molina, Carolina; Morales S, Raul G E; Leiva-Guzmán, Manuel A
2015-09-01
A critical analysis of Chile's National Air Quality Information System (NAQIS) is presented, focusing on particulate matter (PM) measurement. This paper examines the complexity, availability and reliability of monitoring station information, the implementation of control systems, the quality assurance protocols of the monitoring station data and the reliability of the measurement systems in areas highly polluted by particulate matter. From information available on the NAQIS website, it is possible to confirm that the PM2.5 (PM10) data available on the site correspond to 30.8% (69.2%) of the total information available from the monitoring stations. There is a lack of information regarding the measurement systems used to quantify air pollutants, most of the available data registers contain gaps, almost all of the information is categorized as "preliminary information" and neither standard operating procedures (operational and validation) nor assurance audits or quality control of the measurements are reported. In contrast, events that cause saturation of the monitoring detectors located in northern and southern Chile have been observed using beta attenuation monitoring. In these cases, it can only be concluded that the PM content is equal to or greater than the saturation concentration registered by the monitors and that the air quality indexes obtained from these measurements are underestimated. This occurrence has been observed in 12 (20) public and private stations where PM2.5 (PM10) is measured. The shortcomings of the NAQIS data have important repercussions for the conclusions obtained from the data and for how the data are used. However, these issues represent opportunities for improving the system to widen its use, incorporate comparison protocols between equipment, install new stations and standardize the control system and quality assurance. Copyright © 2015 Elsevier Ltd. All rights reserved.
A method of setting limits for the purpose of quality assurance
NASA Astrophysics Data System (ADS)
Sanghangthum, Taweap; Suriyapee, Sivalee; Kim, Gwe-Ya; Pawlicki, Todd
2013-10-01
The result from any assurance measurement needs to be checked against some limits for acceptability. There are two types of limits; those that define clinical acceptability (action limits) and those that are meant to serve as a warning that the measurement is close to the action limits (tolerance limits). Currently, there is no standard procedure to set these limits. In this work, we propose an operational procedure to set tolerance limits and action limits. The approach to establish the limits is based on techniques of quality engineering using control charts and a process capability index. The method is different for tolerance limits and action limits with action limits being categorized into those that are specified and unspecified. The procedure is to first ensure process control using the I-MR control charts. Then, the tolerance limits are set equal to the control chart limits on the I chart. Action limits are determined using the Cpm process capability index with the requirements that the process must be in-control. The limits from the proposed procedure are compared to an existing or conventional method. Four examples are investigated: two of volumetric modulated arc therapy (VMAT) point dose quality assurance (QA) and two of routine linear accelerator output QA. The tolerance limits range from about 6% larger to 9% smaller than conventional action limits for VMAT QA cases. For the linac output QA, tolerance limits are about 60% smaller than conventional action limits. The operational procedure describe in this work is based on established quality management tools and will provide a systematic guide to set up tolerance and action limits for different equipment and processes.
NASA Technical Reports Server (NTRS)
Malarik, Diane C.
2005-01-01
NASA Glenn Research Center s Telescience Support Center (TSC) allows researchers on Earth to operate experiments onboard the International Space Station (ISS) and the space shuttles. NASA s continuing investment in the required software, systems, and networks provides distributed ISS ground operations that enable payload developers and scientists to monitor and control their experiments from the Glenn TSC. The quality of scientific and engineering data is enhanced while the long-term operational costs of experiments are reduced because principal investigators and engineering teams can operate their payloads from their home institutions.
Flight Hardware Fabricated for Combustion Science in Space
NASA Technical Reports Server (NTRS)
OMalley, Terence F.; Weiland, Karen J.
2005-01-01
NASA Glenn Research Center s Telescience Support Center (TSC) allows researchers on Earth to operate experiments onboard the International Space Station (ISS) and the space shuttles. NASA s continuing investment in the required software, systems, and networks provides distributed ISS ground operations that enable payload developers and scientists to monitor and control their experiments from the Glenn TSC. The quality of scientific and engineering data is enhanced while the long-term operational costs of experiments are reduced because principal investigators and engineering teams can operate their payloads from their home institutions.
Wallis, Jason A; Taylor, Nicholas F
2011-12-01
To determine if pre-operative interventions for hip and knee osteoarthritis provide benefit before and after joint replacement. Systematic review with meta-analysis of randomised controlled trials (RCTs) of pre-operative interventions for people with hip or knee osteoarthritis awaiting joint replacement surgery. Standardised mean differences (SMD) were calculated for pain, musculoskeletal impairment, activity limitation, quality of life, and health service utilisation (length of stay and discharge destination). The GRADE approach was used to determine the quality of the evidence. Twenty-three RCTs involving 1461 participants awaiting hip or knee replacement surgery were identified. Meta-analysis provided moderate quality evidence that pre-operative exercise interventions for knee osteoarthritis reduced pain prior to knee replacement surgery (SMD (95% CI)=0.43 [0.13, 0.73]). None of the other meta-analyses investigating pre-operative interventions for knee osteoarthritis demonstrated any effect. Meta-analyses provided low to moderate quality evidence that exercise interventions for hip osteoarthritis reduced pain (SMD (95% CI)=0.52 [0.04, 1.01]) and improved activity (SMD (95% CI)=0.47 [0.11, 0.83]) prior to hip replacement surgery. Meta-analyses provided low quality evidence that exercise with education programs improved activity after hip replacement with reduced time to reach functional milestones during hospital stay (e.g., SMD (95% CI)=0.50 [0.10, 0.90] for first day walking). Low to moderate evidence from mostly small RCTs demonstrated that pre-operative interventions, particularly exercise, reduce pain for patients with hip and knee osteoarthritis prior to joint replacement, and exercise with education programs may improve activity after hip replacement. Copyright © 2011 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Petkewich, Matthew D.; Daamen, Ruby C.; Roehl, Edwin A.; Conrads, Paul
2016-09-29
The generation of Everglades Depth Estimation Network (EDEN) daily water-level and water-depth maps is dependent on high quality real-time data from over 240 water-level stations. To increase the accuracy of the daily water-surface maps, the Automated Data Assurance and Management (ADAM) tool was created by the U.S. Geological Survey as part of Greater Everglades Priority Ecosystems Science. The ADAM tool is used to provide accurate quality-assurance review of the real-time data from the EDEN network and allows estimation or replacement of missing or erroneous data. This user’s manual describes how to install and operate the ADAM software. File structure and operation of the ADAM software is explained using examples.
[Establishing and operating a human biobank. Ethical aspects].
Jahns, Roland
2016-03-01
Particularly in the past decade which has been marked by efforts to foster individualized/personalized medicine the need for well-characterized high-quality collections of human biological material has significantly increased. When establishing and operating a human biobank the interests and the "freedom" of biomedical research must always be weighed against the interests and rights of patients and/or donors; in this process ethical aspects should be considered systematically. In addition, the importance of quality control and quality assurance has largely increased in human biobanking, both from a scientific and even more from an ethical point of view, because donated biological materials are potentially stored for decades and (on request) might serve for currently not foreseeable biomedical research purposes. In addition, the compatibility of national human biobanks with international biobank networks becomes increasingly important.
Zinc thermal spray coatings for reinforced concrete: An AWS process standard
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sulit, R.A.
Zinc and aluminum thermal spray coatings (TSC) have been used for lining concrete weir in Great Britain since the 1950`s to maintain the dimensions of the weir for flow control concomitant with reduced wear and erosion of the concrete surfaces. This paper reports the development and the content of the ANSI/AWS C2.20-XX standard for the application of An TSC on concrete using flame and arc spray processes. This standard is formatted as an industrial process instruction: job description; safety; feedstock materials; equipment; a step-by-step method for surface preparation, thermal spraying; quality control; repair and maintenance of surface preparation, thermal spraying;more » quality control; repair and maintenance of Zn TSC on concrete; and a Job Control Record. Job planning and training and certification requirements are presented for An TSC inspectors and thermal spray operators. Four annexes are included in the standard: (a) historical summary of Zn TSC on concrete (b) sample job control record; (c) thermal spray operator qualification; and (d) portable adhesion testing for An TSC on concrete. This standard is based on the current literature and industrial equipment, process, and practices.« less
NASA Astrophysics Data System (ADS)
Drumheller, Z. W.; Regnery, J.; Lee, J. H.; Illangasekare, T. H.; Kitanidis, P. K.; Smits, K. M.
2014-12-01
Aquifers around the world show troubling signs of irreversible depletion and seawater intrusion as climate change, population growth, and urbanization led to reduced natural recharge rates and overuse. Scientists and engineers have begun to re-investigate the technology of managed aquifer recharge and recovery (MAR) as a means to increase the reliability of the diminishing and increasingly variable groundwater supply. MAR systems offer the possibility of naturally increasing groundwater storage while improving the quality of impaired water used for recharge. Unfortunately, MAR systems remain wrought with operational challenges related to the quality and quantity of recharged and recovered water stemming from a lack of data-driven, real-time control. Our project seeks to ease the operational challenges of MAR facilities through the implementation of active sensor networks, adaptively calibrated flow and transport models, and simulation-based meta-heuristic control optimization methods. The developed system works by continually collecting hydraulic and water quality data from a sensor network embedded within the aquifer. The data is fed into an inversion algorithm, which calibrates the parameters and initial conditions of a predictive flow and transport model. The calibrated model is passed to a meta-heuristic control optimization algorithm (e.g. genetic algorithm) to execute the simulations and determine the best course of action, i.e., the optimal pumping policy for current aquifer conditions. The optimal pumping policy is manually or autonomously applied. During operation, sensor data are used to assess the accuracy of the optimal prediction and augment the pumping strategy as needed. At laboratory-scale, a small (18"H x 46"L) and an intermediate (6'H x 16'L) two-dimensional synthetic aquifer were constructed and outfitted with sensor networks. Data collection and model inversion components were developed and sensor data were validated by analytical measurements.
Vertical flight path steering system for aircraft
NASA Technical Reports Server (NTRS)
Lambregts, Antonius A. (Inventor)
1983-01-01
Disclosed is a vertical flight path angle steering system for aircraft, utilizing a digital flight control computer which processes pilot control inputs and aircraft response parameters into suitable elevator commands and control information for display to the pilot on a cathode ray tube. The system yields desirable airplane control handling qualities and responses as well as improvements in pilot workload and safety during airplane operation in the terminal area and under windshear conditions.
Automation of testing modules of controller ELSY-ТМК
NASA Astrophysics Data System (ADS)
Dolotov, A. E.; Dolotova, R. G.; Petuhov, D. V.; Potapova, A. P.
2017-01-01
In modern life, there are means for automation of various processes which allow one to provide high quality standards of released products and to raise labour efficiency. In the given paper, the data on the automation of the test process of the ELSY-TMK controller [1] is presented. The ELSY-TMK programmed logic controller is an effective modular platform for construction of automation systems for small and average branches of industrial production. The modern and functional standard of communication and open environment of the logic controller give a powerful tool of wide spectrum applications for industrial automation. The algorithm allows one to test controller modules by operating the switching system and external devices faster and at a higher level of quality than a human without such means does.
Assessment of emergency general surgery care based on formally developed quality indicators.
Ingraham, Angela; Nathens, Avery; Peitzman, Andrew; Bode, Allison; Dorlac, Gina; Dorlac, Warren; Miller, Preston; Sadeghi, Mahsa; Wasserman, Deena D; Bilimoria, Karl
2017-08-01
Emergency general surgery outcomes vary widely across the United States. The utilization of quality indicators can reduce variation and assist providers in administering care aligned with established recommendations. Previous quality indicators have not focused on emergency general surgery patients. We identified indicators of high-quality emergency general surgery care and assessed patient- and hospital-level compliance with these indicators. We utilized a modified Delphi technique (RAND Appropriateness Methodology) to develop quality indicators. Through 2 rankings, an expert panel ranked potential quality indicators for validity. We then examined historic compliance with select quality indicators after 4 nonelective procedures (cholecystectomy, appendectomy, colectomy, small bowel resection) at 4 academic centers. Of 25 indicators rated as valid, 13 addressed patient-level quality and 12 addressed hospital-level quality. Adherence with 18 indicators was assessed. Compliance with performing a cholecystectomy for acute cholecystitis within 72 hours of symptom onset ranged from 45% to 76%. Compliance with surgery start times within 3 hours from the decision to operate for uncontained perforated viscus ranged from 20% to 100%. Compliance with exploration of patients with small bowel obstructions with ischemia/impending perforation within 3 hours of the decision to operate was 0% to 88%. For 3 quality indicators (auditing 30-day unplanned readmissions/operations for patients previously managed nonoperatively, monitoring time to source control for intra-abdominal infections, and having protocols for bypass/transfer), none of the hospitals were compliant. Developing indicators for providers to assess their performance provides a foundation for specific initiatives. Adherence to quality indicators may improve the quality of emergency general surgery care provided for which current outcomes are potentially modifiable. Copyright © 2017 Elsevier Inc. All rights reserved.
Recent Developments: PKI Square Dish for the Soleras Project
NASA Technical Reports Server (NTRS)
Rogers, W. E.
1984-01-01
The Square Dish solar collectors are subjected to rigorous design attention regarding corrosion at the site, and certification of the collector structure. The microprocessor controls and tracking mechanisms are improved in the areas of fail safe operations, durability, and low parasitic power requirements. Prototype testing demonstrates performance efficiency of approximately 72% at 730 F outlet temperature. Studies are conducted that include developing formal engineering design studies, developing formal engineering design drawing and fabrication details, establishing subcontracts for fabrication of major components, and developing a rigorous quality control system. The improved design is more cost effective to product and the extensive manuals developed for assembly and operation/maintenance result in faster field assembly and ease of operation.
Recent developments: PKI square dish for the Soleras Project
NASA Astrophysics Data System (ADS)
Rogers, W. E.
1984-03-01
The Square Dish solar collectors are subjected to rigorous design attention regarding corrosion at the site, and certification of the collector structure. The microprocessor controls and tracking mechanisms are improved in the areas of fail safe operations, durability, and low parasitic power requirements. Prototype testing demonstrates performance efficiency of approximately 72% at 730 F outlet temperature. Studies are conducted that include developing formal engineering design studies, developing formal engineering design drawing and fabrication details, establishing subcontracts for fabrication of major components, and developing a rigorous quality control system. The improved design is more cost effective to product and the extensive manuals developed for assembly and operation/maintenance result in faster field assembly and ease of operation.
US Fish and Wildlife Service biomonitoring operations manual, Appendices A--K
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gianotto, D.F.; Rope, R.C.; Mondecar, M.
1993-04-01
Volume 2 contains Appendices and Summary Sheets for the following areas: A-Legislative Background and Key to Relevant Legislation, B- Biomonitoring Operations Workbook, C-Air Monitoring, D-Introduction to the Flora and Fauna for Biomonitoring, E-Decontamination Guidance Reference Field Methods, F-Documentation Guidance, Sample Handling, and Quality Assurance/Quality Control Standard Operating Procedures, G-Field Instrument Measurements Reference Field Methods, H-Ground Water Sampling Reference Field Methods, I-Sediment Sampling Reference Field Methods, J-Soil Sampling Reference Field Methods, K-Surface Water Reference Field Methods. Appendix B explains how to set up strategy to enter information on the ``disk workbook``. Appendix B is enhanced by DE97006389, an on-line workbook formore » users to be able to make revisions to their own biomonitoring data.« less
QCL seeded, ns-pulse, multi-line, CO2 laser oscillator for laser-produced-plasma extreme-UV source
NASA Astrophysics Data System (ADS)
Nowak, Krzysztof Michał; Suganuma, Takashi; Kurosawa, Yoshiaki; Ohta, Takeshi; Kawasuji, Yasufumi; Nakarai, Hiroaki; Saitou, Takashi; Fujimoto, Junichi; Mizoguchi, Hakaru; Sumitani, Akira; Endo, Akira
2017-01-01
Successful merger of state-of-the-art, semiconductor quantum-cascade lasers (QCL), with the mature CO2 laser technology, resulted in a delivery of highly-desired qualities of CO2 laser output that were not available previously without much effort. These qualities, such as multi-line operation, excellent spectro-temporal stability and pulse waveform control, became available from a single device of moderate complexity. This paper describes the operation principle and the unique properties of the solid{state seeded CO2 laser, invented for an application in laser-produced-plasma (LPP), extreme-UV (EUV) light source.
Body image and college women's quality of life: The importance of being self-compassionate.
Duarte, Cristiana; Ferreira, Cláudia; Trindade, Inês A; Pinto-Gouveia, José
2015-06-01
This study explored self-compassion as a mediator between body dissatisfaction, social comparison based on body image and quality of life in 662 female college students. Path analysis revealed that while controlling for body mass index, self-compassion mediated the impact of body dissatisfaction and unfavourable social comparisons on psychological quality of life. The path model accounted for 33 per cent of psychological quality of life variance. Findings highlight the importance of self-compassion as a mechanism that may operate on the association between negative body image evaluations and young women's quality of life. © The Author(s) 2015.
The integrated manual and automatic control of complex flight systems
NASA Technical Reports Server (NTRS)
Schmidt, David K.
1991-01-01
Research dealt with the general area of optimal flight control synthesis for manned flight vehicles. The work was generic; no specific vehicle was the focus of study. However, the class of vehicles generally considered were those for which high authority, multivariable control systems might be considered, for the purpose of stabilization and the achievement of optimal handling characteristics. Within this scope, the topics of study included several optimal control synthesis techniques, control-theoretic modeling of the human operator in flight control tasks, and the development of possible handling qualities metrics and/or measures of merit. Basic contributions were made in all these topics, including human operator (pilot) models for multi-loop tasks, optimal output feedback flight control synthesis techniques; experimental validations of the methods developed, and fundamental modeling studies of the air-to-air tracking and flared landing tasks.
NASA Astrophysics Data System (ADS)
Chen, Min; Zhang, Yu
2017-04-01
A wind profiler network with a total of 65 profiling radars was operated by the MOC/CMA in China until July 2015. In this study, a quality control procedure is constructed to incorporate the profiler data from the wind-profiling network into the local data assimilation and forecasting system (BJRUC). The procedure applies a blacklisting check that removes stations with gross errors and an outlier check that rejects data with large deviations from the background. Instead of the bi-weighting method, which has been commonly implemented in outlier elimination for one-dimensional scalar observations, an outlier elimination method is developed based on the iterated reweighted minimum covariance determinant (IRMCD) for multi-variate observations such as wind profiler data. A quality control experiment is separately performed for subsets containing profiler data tagged in parallel with/without rain flags at every 00UTC/12UTC from 20 June to 30 Sep 2015. From the results, we find that with the quality control, the frequency distributions of the differences between the observations and model background become more Gaussian-like and meet the requirements of a Gaussian distribution for data assimilation. Further intensive assessment for each quality control step reveals that the stations rejected by blacklisting contain poor data quality, and the IRMCD rejects outliers in a robust and physically reasonable manner.
Control of Technology Transfer at JPL
NASA Technical Reports Server (NTRS)
Oliver, Ronald
2006-01-01
Controlled Technology: 1) Design: preliminary or critical design data, schematics, technical flow charts, SNV code/diagnostics, logic flow diagrams, wirelist, ICDs, detailed specifications or requirements. 2) Development: constraints, computations, configurations, technical analyses, acceptance criteria, anomaly resolution, detailed test plans, detailed technical proposals. 3) Production: process or how-to: assemble, operated, repair, maintain, modify. 4) Manufacturing: technical instructions, specific parts, specific materials, specific qualities, specific processes, specific flow. 5) Operations: how-to operate, contingency or standard operating plans, Ops handbooks. 6) Repair: repair instructions, troubleshooting schemes, detailed schematics. 7) Test: specific procedures, data, analysis, detailed test plan and retest plans, detailed anomaly resolutions, detailed failure causes and corrective actions, troubleshooting, trended test data, flight readiness data. 8) Maintenance: maintenance schedules and plans, methods for regular upkeep, overhaul instructions. 9) Modification: modification instructions, upgrades kit parts, including software
Jennings, Larissa; Bertrand, Jane; Rech, Dino; Harvey, Steven A.; Hatzold, Karin; Samkange, Christopher A.; Omondi Aduda, Dickens S.; Fimbo, Bennett; Cherutich, Peter; Perry, Linnea; Castor, Delivette; Njeuhmeli, Emmanuel
2014-01-01
Background The rapid expansion of voluntary medical male circumcision (VMMC) has raised concerns whether health systems can deliver and sustain VMMC according to minimum quality criteria. Methods and Findings A comparative process evaluation was used to examine data from SYMMACS, the Systematic Monitoring of the Voluntary Medical Male Circumcision Scale-Up, among health facilities providing VMMC across two years of program scale-up. Site-level assessments examined the availability of guidelines, supplies and equipment, infection control, and continuity of care services. Direct observation of VMMC surgeries were used to assess care quality. Two sample tests of proportions and t-tests were used to examine differences in the percent of facilities meeting requisite preparedness standards and the mean number of directly-observed surgical tasks performed correctly. Results showed that safe, high quality VMMC can be implemented and sustained at-scale, although substantial variability was observed over time. In some settings, facility preparedness and VMMC service quality improved as the number of VMMC facilities increased. Yet, lapses in high performance and expansion of considerably deficient services were also observed. Surgical tasks had the highest quality scores, with lower performance levels in infection control, pre-operative examinations, and post-operative patient monitoring and counseling. The range of scale-up models used across countries additionally underscored the complexity of delivering high quality VMMC. Conclusions Greater efforts are needed to integrate VMMC scale-up and quality improvement processes in sub-Saharan African settings. Monitoring of service quality, not just adverse events reporting, will be essential in realizing the full health impact of VMMC for HIV prevention. PMID:24801073
Sozzi, R; Bolignano, A; Ceradini, S; Morelli, M; Petenko, I; Argentini, S
2017-10-15
According to the European Directive 2008/50/CE, the air quality assessment consists in the measurement of the concentration fields, and the evaluation of the mean, number of exceedances, etc. of some chemical species dangerous to human health. The measurements provided by an air quality ground-based monitoring network are the main information source but the availability of these data is often limited by several technical and operational problems. In this paper, the best linear unbiased estimator (BLUE) is proposed to validate the pollutant concentration values and to fill the gaps in the measurement of time series collected by a monitoring network. The BLUE algorithm is tested using the daily mean concentrations of particulate matter having aerodynamic diameter less than 10 μ (PM 10 concentrations) measured by the air quality monitoring sensors operating in the Lazio Region in Italy. The comparison between the estimated and measured data evidences an error comparable with the measurement uncertainty. Due to its simplicity and reliability, the BLUE will be used in the routine quality test procedures of the Lazio air quality monitoring network measurements.
NASA Technical Reports Server (NTRS)
Carter, John; Stephenson, Mark
1999-01-01
The NASA Dryden Flight Research Center has completed the initial flight test of a modified set of F/A-18 flight control computers that gives the aircraft a research control law capability. The production support flight control computers (PSFCC) provide an increased capability for flight research in the control law, handling qualities, and flight systems areas. The PSFCC feature a research flight control processor that is "piggybacked" onto the baseline F/A-18 flight control system. This research processor allows for pilot selection of research control law operation in flight. To validate flight operation, a replication of a standard F/A-18 control law was programmed into the research processor and flight-tested over a limited envelope. This paper provides a brief description of the system, summarizes the initial flight test of the PSFCC, and describes future experiments for the PSFCC.
Livestock Waste Management in a Quality Environment. Circular 1074.
ERIC Educational Resources Information Center
Jedele, D. G., Ed.
This circular provides information to assist in assessing the pollution potential of livestock operations. It discusses a systematic approach to resolving problems through feedlot runoff control, liquid manure handling, hauling and lagooning, and ditching. (CS)
30 CFR 75.337 - Construction and repair of seals.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 days of completion of quality control tests. (f) Welding, cutting, and soldering. Welding, cutting, and soldering with an arc or flame are prohibited within 150 feet of a seal. An operator may request a...
30 CFR 75.337 - Construction and repair of seals.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 days of completion of quality control tests. (f) Welding, cutting, and soldering. Welding, cutting, and soldering with an arc or flame are prohibited within 150 feet of a seal. An operator may request a...
30 CFR 75.337 - Construction and repair of seals.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 days of completion of quality control tests. (f) Welding, cutting, and soldering. Welding, cutting, and soldering with an arc or flame are prohibited within 150 feet of a seal. An operator may request a...
Social cognitive theory: an agentic perspective.
Bandura, A
2001-01-01
The capacity to exercise control over the nature and quality of one's life is the essence of humanness. Human agency is characterized by a number of core features that operate through phenomenal and functional consciousness. These include the temporal extension of agency through intentionality and forethought, self-regulation by self-reactive influence, and self-reflectiveness about one's capabilities, quality of functioning, and the meaning and purpose of one's life pursuits. Personal agency operates within a broad network of sociostructural influences. In these agentic transactions, people are producers as well as products of social systems. Social cognitive theory distinguishes among three modes of agency: direct personal agency, proxy agency that relies on others to act on one's behest to secure desired outcomes, and collective agency exercised through socially coordinative and interdependent effort. Growing transnational embeddedness and interdependence are placing a premium on collective efficacy to exercise control over personal destinies and national life.
NASA Astrophysics Data System (ADS)
Barufaldi, Bruno; Borges, Lucas R.; Bakic, Predrag R.; Vieira, Marcelo A. C.; Schiabel, Homero; Maidment, Andrew D. A.
2017-03-01
Automatic exposure control (AEC) is used in mammography to obtain acceptable radiation dose and adequate image quality regardless of breast thickness and composition. Although there are physics methods for assessing the AEC, it is not clear whether mammography systems operate with optimal dose and image quality in clinical practice. In this work, we propose the use of a normalized anisotropic quality index (NAQI), validated in previous studies, to evaluate the quality of mammograms acquired using AEC. The authors used a clinical dataset that consists of 561 patients and 1,046 mammograms (craniocaudal breast views). The results show that image quality is often maintained, even at various radiation levels (mean NAQI = 0.14 +/- 0.02). However, a more careful analysis of NAQI reveals that the average image quality decreases as breast thickness increases. The NAQI is reduced by 32% on average, when the breast thickness increases from 31 to 71 mm. NAQI also decreases with lower breast density. The variation in breast parenchyma alone cannot fully account for the decrease of NAQI with thickness. Examination of images shows that images of large, fatty breasts are often inadequately processed. This work shows that NAQI can be applied in clinical mammograms to assess mammographic image quality, and highlights the limitations of the automatic exposure control for some images.
V/STOL Dynamics, Control, and Flying Qualities
NASA Technical Reports Server (NTRS)
Franklin, James A.
2000-01-01
This publication presents material that constituted the lectures presented by the author as part of Course AA 234, Dynamics, Control, and Flying Qualities of Vertical/Short Takeoff and Landing (V/STOL) Aircraft that was taught in the Department of Aeronautics and Astronautics at Stanford University. It covers representative operations of vertical and short takeoff and landing (V/STOL) aircraft, a discussion of the pilot's strategy in controlling these aircraft, the equations of motion pertinent to V/STOL tasks, and their application in the analysis of longitudinal and lateral-directional control in hover and forward flight. Following that development, which applies to the characteristics of the basic airframe and propulsion system, the text concludes with a discussion of the contributions of control augmentation in specific flight tasks and of the integration of modern electronic displays with these controls.
The U.S. EPA has created the Environmental Technology Verification (ETV) Program. ETV seeks to provide high-quality, peer-reviewed data on technology performance. The Air Pollution Control Technology (APCT) Verification Center, a center under the ETV Program, is operated by Res...
A flight evaluation of VTOL jet transport under visual and simulated instrument conditions
NASA Technical Reports Server (NTRS)
Holzhauser, C. A.; Morello, S. A.; Innis, R. C.; Patton, J. M., Jr.
1972-01-01
A flight investigation was performed with the Dornier DO-31 VTOL to evaluate the performance, handling qualities, and operating characteristics that are considered to be important in the operation of a commerical VTOL transport in the terminal area. The DO-31, a 20,000 kilogram transport, has a mixed jet propulsion system; main engines with nozzles deflect from a cruise to a hover position, and vertical lift engines operated below 170 knots. This VTOL mode incorporates pitch and roll attitude and yaw rate stabilization. The tests concentrated on the transition, approach, and vertical landing. The mixed jet propulsion system provided a large usable performance envelope that enabled simulated IFR approaches to be made on 7 deg and 12 deg glide slopes. In these approaches management of thrust magnitude and direction was a primary problem, and some form of integrating the controls will be necessary. The handling qualities evaluation pointed out the need for additional research of define flight path criteria. The aircraft had satisfactory control and stability in hover out of ground effect. The recirculation effects in vertical landing were large below 15 meters.
In-situ quality monitoring during laser brazing
NASA Astrophysics Data System (ADS)
Ungers, Michael; Fecker, Daniel; Frank, Sascha; Donst, Dmitri; Märgner, Volker; Abels, Peter; Kaierle, Stefan
Laser brazing of zinc coated steel is a widely established manufacturing process in the automotive sector, where high quality requirements must be fulfilled. The strength, impermeablitiy and surface appearance of the joint are particularly important for judging its quality. The development of an on-line quality control system is highly desired by the industry. This paper presents recent works on the development of such a system, which consists of two cameras operating in different spectral ranges. For the evaluation of the system, seam imperfections are created artificially during experiments. Finally image processing algorithms for monitoring process parameters based the captured images are presented.
NASA Technical Reports Server (NTRS)
Mathews, Charles W; Talmage, Donald B; Whitten, James B
1951-01-01
The longitudinal stability and control characteristics of a B-29 airplane have been measured with a control surface booster incorporated in the elevator-control system. The measurements were obtained with the booster operating to provide various control-force gradients and various maximum rates of control motion. Results are presented which show the effect of these booster parameters on the handling qualities of the test airplane.
The operator's emotional stability
NASA Technical Reports Server (NTRS)
Zilberman, P. B.
1975-01-01
An attempt is made to provide a psychological interpretation of the concept of emotional stability in connection with other psychics qualities of an operator's personality. Emotional stability is understood as a person's capacity to control his emotional state for the purpose of maintaining the necessary level of work performance under extreme stress conditions. By modeling the operator's sensorimotor activity and by comparing the productivity indicators under ordinary conditions with those obtained during work involving an emotional load, the level of emotional stability can be determined.
Earth Observation Data Quality Monitoring and Control: A Case Study of STAR Central Data Repository
NASA Astrophysics Data System (ADS)
Han, W.; Jochum, M.
2017-12-01
Earth observation data quality is very important for researchers and decision makers involved in weather forecasting, severe weather warning, disaster and emergency response, environmental monitoring, etc. Monitoring and control earth observation data quality, especially accuracy, completeness, and timeliness, is very useful in data management and governance to optimize data flow, discover potential transmission issues, and better connect data providers and users. Taking a centralized near real-time satellite data repository, STAR (Center for Satellite Applications and Research of NOAA) Central Data Repository (SCDR), as an example, this paper describes how to develop new mechanism to verify data integrity, check data completeness, and monitor data latency in an operational data management system. Such quality monitoring and control of large volume satellite data help data providers and managers improve data transmission of near real-time satellite data, enhance its acquisition and management, and overcome performance and management issues to better serve research and development activities.
NASA Astrophysics Data System (ADS)
Arya, Sabha Raj; Patel, Ashish; Giri, Ashutosh
2018-06-01
This paper deals wind energy based power generation system using Permanent Magnet Synchronous Generator (PMSG). It is controlled using advanced enhanced phase-lock loop for power quality features using distribution static compensator to eliminate the harmonics and to provide KVAR compensation as well as load balancing. It also manages rated potential at the point of common interface under linear and non-linear loads. In order to have better efficiency and reliable operation of PMSG driven by wind turbine, it is necessary to analyze the governing equation of wind based turbine and PMSG under fixed and variable wind speed. For handling power quality problems, power electronics based shunt connected custom power device is used in three wire system. The simulations in MATLAB/Simulink environment have been carried out in order to demonstrate this model and control approach used for the power quality enhancement. The performance results show the adequate performance of PMSG based power generation system and control algorithm.
NASA Astrophysics Data System (ADS)
Arya, Sabha Raj; Patel, Ashish; Giri, Ashutosh
2018-03-01
This paper deals wind energy based power generation system using Permanent Magnet Synchronous Generator (PMSG). It is controlled using advanced enhanced phase-lock loop for power quality features using distribution static compensator to eliminate the harmonics and to provide KVAR compensation as well as load balancing. It also manages rated potential at the point of common interface under linear and non-linear loads. In order to have better efficiency and reliable operation of PMSG driven by wind turbine, it is necessary to analyze the governing equation of wind based turbine and PMSG under fixed and variable wind speed. For handling power quality problems, power electronics based shunt connected custom power device is used in three wire system. The simulations in MATLAB/Simulink environment have been carried out in order to demonstrate this model and control approach used for the power quality enhancement. The performance results show the adequate performance of PMSG based power generation system and control algorithm.
Berkő, Péter
2016-05-01
It is a regrettable deficiency in the Hungarian healthcare that the culture and the system of quality control of cure have not been formed (except for a few subspecialties, units or wards). If hospital wards do not have a national, professionally unified and modern information system presenting the most important quantity and quality indicators of their medicinal activity annually, a stable basis for definition of future tasks is absent. The author puts forward a proposal for the establishment of the information systems for different professional fields. On the basis of experience of perinatological information system operating for over 3 decades in Borsod-Abaúj-Zemplén county, he also proposes introduction of a nationally unified, Europeristat-compatible information system following Tauffer-statistics which may serve as a uniform quality control of obstetrics and perinatological care, as well as introduction of its base, the dataform "TePERA" (Form of Obstetrics and Perinatological Care Risk).
Command and Control Common Semantic Core Required to Enable Net-centric Operations
2008-05-20
automated processing capability. A former US Marine Corps component C4 director during Operation Iraqi Freedom identified the problems of 1) uncertainty...interoperability improvements to warfighter community processes, thanks to ubiquitous automated processing , are likely high and somewhat easier to quantify. A...synchronized with the actions of other partners / warfare communities. This requires high- quality information, rapid sharing and automated processing – which
Bulk shielding facility quarterly report, October, November, and December 1976
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hurt, III, S. S.; Lance, E. D.; Thomas, J. R.
1977-08-01
The BSR operated at an average power level of 1,836 kw for 78.01 percent of the time during October, November, and December. Water-quality control in both the reactor primary and secondary cooling systems was satisfactory. The PCA was used in training programs and was operated on two occasions when the University of Kentucky students actively participated in training laboratories.
Trends and Issues in U.S. Navy Manpower
1985-01-01
Planning (ADSTAP) system7, consists of several subsystems and models for planning and managing enlisted manpower, personnel, and training. It was... models to provide information for formulating goals and planning the transition from current inventory to estab- lished objectives 9 Operational...planning models to provide information for formulating operating plans to control the size and quality (ratings or skills and pay grades) of the active-duty
Air quality mapping using GIS and economic evaluation of health impact for Mumbai City, India.
Kumar, Awkash; Gupta, Indrani; Brandt, Jørgen; Kumar, Rakesh; Dikshit, Anil Kumar; Patil, Rashmi S
2016-05-01
Mumbai, a highly populated city in India, has been selected for air quality mapping and assessment of health impact using monitored air quality data. Air quality monitoring networks in Mumbai are operated by National Environment Engineering Research Institute (NEERI), Maharashtra Pollution Control Board (MPCB), and Brihanmumbai Municipal Corporation (BMC). A monitoring station represents air quality at a particular location, while we need spatial variation for air quality management. Here, air quality monitored data of NEERI and BMC were spatially interpolated using various inbuilt interpolation techniques of ArcGIS. Inverse distance weighting (IDW), Kriging (spherical and Gaussian), and spline techniques have been applied for spatial interpolation for this study. The interpolated results of air pollutants sulfur dioxide (SO2), nitrogen dioxide (NO2) and suspended particulate matter (SPM) were compared with air quality data of MPCB in the same region. Comparison of results showed good agreement for predicted values using IDW and Kriging with observed data. Subsequently, health impact assessment of a ward was carried out based on total population of the ward and air quality monitored data within the ward. Finally, health cost within a ward was estimated on the basis of exposed population. This study helps to estimate the valuation of health damage due to air pollution. Operating more air quality monitoring stations for measurement of air quality is highly resource intensive in terms of time and cost. The appropriate spatial interpolation techniques can be used to estimate concentration where air quality monitoring stations are not available. Further, health impact assessment for the population of the city and estimation of economic cost of health damage due to ambient air quality can help to make rational control strategies for environmental management. The total health cost for Mumbai city for the year 2012, with a population of 12.4 million, was estimated as USD8000 million.
Findeisen, Peter; Thumfart, Jörg Oliver; Costina, Victor; Hofheinz, Ralf; Neumaier, Michael
2013-09-01
To determine the preanalytical quality of serum and plasma by monitoring the time-dependent ex vivo decay of a synthetic reporter peptide (RP) with liquid chromatography/mass spectrometry (LC/MS). Serum and plasma specimens were spiked with the RP and proteolytic fragments were monitored with LC/MS at different preanalytical time points ranging from 2 to 24 hours after blood withdrawal. The concentration of fragments changed in a time-dependent manner, and respective peptide profiles were used to classify specimens according to their preanalytical time span. Classification accuracy was high, with values always above 0.89 for areas under receiver operating characteristic curves. This "proteomics degradation clock" can be used to estimate the preanalytical quality of serum and plasma and might have impact on quality control procedures of biobanking repositories.
A Systems Approach to Manage Drinking Water Quality ...
Drinking water supplies can be vulnerable to impacts from short-term weather events, long-term changes in land-use and climate, and water quality controls in treatment and distribution. Disinfection by-product (DBP) formation in drinking water is a prominent example to illustrate the water supply vulnerability and examine technological options in adaptation. Total organic carbon (TOC) in surface water can vary significantly due to changes or a combination of changes in watershed land use, climate variability, and extreme meteorological events (e.g., hurricanes). On the other hand, water demand is known to vary temporarily and spatially leading to changes in water ages and hence DBP formation potential. Typically a drinking water facility is designed to operate within a projected range of influent water quality and water demand. When the variations exceed the design range, water supply becomes vulnerable in the compliance to Safe Drinking Water Act (SDWA) Stage-II disinfection by-product (DBP) rules. This paper describes a framework of systems-level modeling, monitoring and control in adaptive planning and system operation. The framework, built upon the integration of model projections, adaptive monitoring and systems control, has three primary functions. Its advantages and limitations will be discussed with the application examples in Cincinnati (Ohio, USA) and Las Vegas (Nevada, USA). At a conceptual level, an integrated land use and hydrological model
Latest processing status and quality assessment of the GOMOS, MIPAS and SCIAMACHY ESA dataset
NASA Astrophysics Data System (ADS)
Niro, F.; Brizzi, G.; Saavedra de Miguel, L.; Scarpino, G.; Dehn, A.; Fehr, T.; von Kuhlmann, R.
2011-12-01
GOMOS, MIPAS and SCIAMACHY instruments are successfully observing the changing Earth's atmosphere since the launch of the ENVISAT-ESA platform on March 2002. The measurements recorded by these instruments are relevant for the Atmospheric-Chemistry community both in terms of time extent and variety of observing geometry and techniques. In order to fully exploit these measurements, it is crucial to maintain a good reliability in the data processing and distribution and to continuously improving the scientific output. The goal is to meet the evolving needs of both the near-real-time and research applications. Within this frame, the ESA operational processor remains the reference code, although many scientific algorithms are nowadays available to the users. In fact, the ESA algorithm has a well-established calibration and validation scheme, a certified quality assessment process and the possibility to reach a wide users' community. Moreover, the ESA algorithm upgrade procedures and the re-processing performances have much improved during last two years, thanks to the recent updates of the Ground Segment infrastructure and overall organization. The aim of this paper is to promote the usage and stress the quality of the ESA operational dataset for the GOMOS, MIPAS and SCIAMACHY missions. The recent upgrades in the ESA processor (GOMOS V6, MIPAS V5 and SCIAMACHY V5) will be presented, with detailed information on improvements in the scientific output and preliminary validation results. The planned algorithm evolution and on-going re-processing campaigns will be mentioned that involves the adoption of advanced set-up, such as the MIPAS V6 re-processing on a clouds-computing system. Finally, the quality control process will be illustrated that allows to guarantee a standard of quality to the users. In fact, the operational ESA algorithm is carefully tested before switching into operations and the near-real time and off-line production is thoughtfully verified via the implementation of automatic quality control procedures. The scientific validity of the ESA dataset will be additionally illustrated with examples of applications that can be supported, such as ozone-hole monitoring, volcanic ash detection and analysis of atmospheric composition changes during the past years.
Norton, Peter G; Murray, Michael; Doupe, Malcolm B; Cummings, Greta G; Poss, Jeff W; Squires, Janet E; Teare, Gary F; Estabrooks, Carole A
2014-01-01
Objectives To demonstrate the benefit of defining operational management units in nursing homes and computing quality indicators on these units as well as on the whole facility. Design Calculation of adjusted Resident Assessment Instrument – Minimum Data Set 2.0 (RAI–MDS 2.0) quality indicators for: PRU05 (prevalence of residents with a stage 2–4 pressure ulcer), PAI0X (prevalence of residents with pain) and DRG01 (prevalence of residents receiving an antipsychotic with no diagnosis of psychosis), for quarterly assessments between 2007 and 2011 at unit and facility levels. Comparisons of these risk-adjusted quality indicators using statistical process control (control charts). Setting A representative sample of 30 urban nursing homes in the three Canadian Prairie Provinces. Measurements Explicit decision rules were developed and tested to determine whether the control charts demonstrated improving, worsening, unchanging or unclassifiable trends over the time period. Unit and facility performance were compared. Results In 48.9% of the units studied, unit control chart performance indicated different changes in quality over the reporting period than did the facility chart. Examples are provided to illustrate that these differences lead to quite different quality interventions. Conclusions Our results demonstrate the necessity of considering facility-level and unit-level measurement when calculating quality indicators derived from the RAI–MDS 2.0 data, and quite probably from any RAI measures. PMID:24523428
NASA Astrophysics Data System (ADS)
Phaterpekar, Siddhesh Nitin
The scope of this article is to cover the synthesis and quality control procedures involved in production of Fludeoxyglucose (18F--FDG). The article also describes the cyclotron production of 18F radioisotope and gives a brief overview on operations and working of a fixed energy medical cyclotron. The quality control procedures for FDG involve radiochemical and radionuclidic purity tests, pH tests, chemical purity tests, sterility tests, endotoxin tests. Each of these procedures were carried out for multiple batches of FDG with a passing rate of 95% among 20 batches. The article also covers the quality assurance steps for the Siemens MicroPET Focus 220 Scanner using a Jaszczak phantom. We have carried out spatial resolution tests on the scanner, with an average transaxial resolution of 1.775mm with 2-3mm offset. Tests involved detector efficiency, blank scan sinograms and transmission sinograms. A series of radioactivity distribution tests are also carried out on a uniform phantom, denoting the variations in radioactivity and uniformity by using cylindrical ROIs in the transverse region of the final image. The purpose of these quality control tests is to make sure the manufactured FDG is biocompatible with the human body. Quality assurance tests are carried on PET scanners for efficient performance, and to make sure the quality of images acquired is according to the radioactivity distribution in the subject of interest.
The six critical attributes of the next generation of quality management software systems.
Clark, Kathleen
2011-07-01
Driven by both the need to meet regulatory requirements and a genuine desire to drive improved quality, quality management systems encompassing standard operating procedure, corrective and preventative actions and related processes have existed for many years, both in paper and electronic form. The impact of quality management systems on 'actual' quality, however, is often reported as far less than desired. A quality management software system that moves beyond formal forms-driven processes to include a true closed loop design, manage disparate processes across the enterprise, provide support for collaborative processes and deliver insight into the overall state of control has the potential to close the gap between simply accomplishing regulatory compliance and delivering measurable improvements in quality and efficiency.
Beach, Scott R; Schulz, Richard; Matthews, Judith T; Courtney, Karen; Dabbs, Annette DeVito
2014-11-01
Quality of Life technology (QoLT) stresses humans and technology as mutually dependent and aware, working together to improve task performance and quality of life. This study examines preferences for technology versus human assistance and control in the context of QoLT. Data are from a nationally representative, cross-sectional web-based sample of 416 US baby boomers (45-64) and 114 older adults (65+) on preferences for technology versus human assistance and control in the performance of kitchen and personal care tasks. Multinomial logistic regression and ordinary least squares regression were used to determine predictors of these preferences. Respondents were generally accepting of technology assistance but wanted to maintain control over its' operation. Baby boomers were more likely to prefer technology than older adults, and those with fewer QoLT privacy concerns and who thought they were more likely to need future help were more likely to prefer technology over human assistance and more willing to relinquish control to technology. Results suggest the need for design of person- and context-aware QoLT systems that are responsive to user desires for level of control over operation of the technology. The predictors of these preferences suggest potentially receptive markets for the targeting of QoLT systems.
A multichannel amplitude and relative-phase controller for active sound quality control
NASA Astrophysics Data System (ADS)
Mosquera-Sánchez, Jaime A.; Desmet, Wim; de Oliveira, Leopoldo P. R.
2017-05-01
The enhancement of the sound quality of periodic disturbances for a number of listeners within an enclosure often confronts difficulties given by cross-channel interferences, which arise from simultaneously profiling the primary sound at each error sensor. These interferences may deteriorate the original sound among each listener, which is an unacceptable result from the point of view of sound quality control. In this paper we provide experimental evidence on controlling both amplitude and relative-phase functions of stationary complex primary sounds for a number of listeners within a cavity, attaining amplifications of twice the original value, reductions on the order of 70 dB, and relative-phase shifts between ± π rad, still in a free-of-interference control scenario. To accomplish such burdensome control targets, we have designed a multichannel active sound profiling scheme that bases its operation on exchanging time-domain control signals among the control units during uptime. Provided the real parts of the eigenvalues of persistently excited control matrices are positive, the proposed multichannel array is able to counterbalance cross-channel interferences, while attaining demanding control targets. Moreover, regularization of unstable control matrices is not seen to prevent the proposed array to provide free-of-interference amplitude and relative-phase control, but the system performance is degraded, as a function of the amount of regularization needed. The assessment of Loudness and Roughness metrics on the controlled primary sound proves that the proposed distributed control scheme noticeably outperforms current techniques, since active amplitude- and/or relative-phase-based enhancement of the auditory qualities of a primary sound no longer implies in causing interferences among different positions. In this regard, experimental results also confirm the effectiveness of the proposed scheme on stably enhancing the sound qualities of periodic sounds for multiple listeners within a cavity.
Assimilation of IASI and AIRS Data: Information Content and Quality Control
NASA Technical Reports Server (NTRS)
Joiner, J.; Einaudi, Franco (Technical Monitor)
2000-01-01
The Infrared Atmospheric Sounding Interferometer (IASI) and Atmospheric Infrared Sounder (AIRS) instruments have two orders of magnitude more channels that the current operational infrared sounder (High Resolution Infra-Red Sounder (HIRS)). This data volume presents a technological challenge for using the data in a data assimilation system. Data reduction will be a necessary for assimilation. It is important to understand the information content of the radiance measurements for data reduction purposes. In this talk, I will discuss issues relating to information content and quality control for assimilation of the AIRS and IASI data.
NASA Technical Reports Server (NTRS)
Onate, Bryan
2016-01-01
The International Space Station (ISS) will soon have a platform for conducting fundamental research of Large Plants. Plant Habitat (PH) is designed to be a fully controllable environment for high-quality plant physiological research. PH will control light quality, level, and timing, temperature, CO2, relative humidity, and irrigation, while scrubbing ethylene. Additional capabilities include leaf temperature and root zone moisture and oxygen sensing. The light cap will have red (630 nm), blue (450 nm), green (525 nm), far red (730 nm) and broad spectrum white LEDs. There will be several internal cameras (visible and IR) to monitor and record plant growth and operations.
Simões, Marta F; Dias, Nicolina; Santos, Cledir; Lima, Nelson
2016-06-22
Collaborations between different Microbiological Resource Centres (mBRCs) and ethical sourcing practices are mandatory to guarantee biodiversity conservation, successful and sustainable preservation and fair share of benefits that arise from the use of genetic resources. Since microbial Culture Collections (CCs) are now engaged in meeting high quality operational standards, they are facing the challenge of establishing quality control criteria to certify their biological materials. The authentication/certification of strains is nowadays a demand from the bioeconomy sector for the global operation of mBRCs. The achievement of consistent quality assurance and trust within the mBRCs and microbial CCs context is a dynamic and never-ending process. A good option to facilitate that process is to implement a Quality Management System (QMS) based on the ISO 9001 standard. Here, we report a detailed description of all the steps taken for the QMS implementation at the Portuguese CC of filamentous fungi: Micoteca da Universidade do Minho (MUM). Our aim is to provide guidelines for the certification of other CCs, so that they can also enhance the search and choice of the most consistent, reliable, and effective operating methods, with assured procedures and validation of preservation; and guarantee trustworthy relations with all stakeholders.
Simões, Marta F.; Dias, Nicolina; Santos, Cledir; Lima, Nelson
2016-01-01
Collaborations between different Microbiological Resource Centres (mBRCs) and ethical sourcing practices are mandatory to guarantee biodiversity conservation, successful and sustainable preservation and fair share of benefits that arise from the use of genetic resources. Since microbial Culture Collections (CCs) are now engaged in meeting high quality operational standards, they are facing the challenge of establishing quality control criteria to certify their biological materials. The authentication/certification of strains is nowadays a demand from the bioeconomy sector for the global operation of mBRCs. The achievement of consistent quality assurance and trust within the mBRCs and microbial CCs context is a dynamic and never-ending process. A good option to facilitate that process is to implement a Quality Management System (QMS) based on the ISO 9001 standard. Here, we report a detailed description of all the steps taken for the QMS implementation at the Portuguese CC of filamentous fungi: Micoteca da Universidade do Minho (MUM). Our aim is to provide guidelines for the certification of other CCs, so that they can also enhance the search and choice of the most consistent, reliable, and effective operating methods, with assured procedures and validation of preservation; and guarantee trustworthy relations with all stakeholders. PMID:27681915
NASA Astrophysics Data System (ADS)
Mizhidon, A. D.; Mizhidon, K. A.
2017-04-01
An analytic-numerical method for the construction of a reference law of operation for a class of dynamic systems describing vibrations in controlled mechanical systems is proposed. By the reference law of operation of a system, we mean a law of the system motion that satisfies all the requirements for the quality and design features of the system under permanent external disturbances. As disturbances, we consider polyharmonic functions with known amplitudes and frequencies of the harmonics but unknown initial phases. For constructing the reference law of motion, an auxiliary optimal control problem is solved in which the cost function depends on a weighting coefficient. The choice of the weighting coefficient ensures the design of the reference law. Theoretical foundations of the proposed method are given.