Sample records for quality control performance

  1. Relationship between antigravity control and postural control in young children.

    PubMed

    Sellers, J S

    1988-04-01

    The purposes of this study were 1) to determine the relationship between antigravity control (supine flexion and prone extension) and postural control (static and dynamic balance), 2) to determine the quality of antigravity and postural control, and 3) to determine whether sex and ethnic group differences correlate with differences in antigravity control and postural control in young children. I tested 107 black, Hispanic, and Caucasian children in a Head Start program, with a mean age of 61 months. The study results showed significant relationships between antigravity control and postural control. Subjects' supine flexion performance was significantly related to the quantity and quality of their static and dynamic balance performance, whereas prone extension performance was related only to the quality of dynamic balance performance. Quality scale measurements (r = .90) indicated that the children in this study had not yet developed full antigravity or postural control. The study results revealed differences between sexes in the quality of static balance and prone extension performance and ethnic differences in static balance, dynamic balance, and prone extension performance.

  2. 7 CFR 275.21 - Quality control review reports.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 4 2011-01-01 2011-01-01 false Quality control review reports. 275.21 Section 275.21... Reporting on Program Performance § 275.21 Quality control review reports. (a) General. Each State agency shall submit reports on the performance of quality control reviews in accordance with the requirements...

  3. Contractor Performed Quality Control on KyTC Projects.

    DOT National Transportation Integrated Search

    2002-08-01

    This report addresses issues related to transferring the responsibility for quality control from the Kentucky Transportation Cabinet (KyTC) to construction contractors. : Several key topics related to Contractor Performed Quality Control (CPQC) are p...

  4. Guidance for Efficient Small Animal Imaging Quality Control.

    PubMed

    Osborne, Dustin R; Kuntner, Claudia; Berr, Stuart; Stout, David

    2017-08-01

    Routine quality control is a critical aspect of properly maintaining high-performance small animal imaging instrumentation. A robust quality control program helps produce more reliable data both for academic purposes and as proof of system performance for contract imaging work. For preclinical imaging laboratories, the combination of costs and available resources often limits their ability to produce efficient and effective quality control programs. This work presents a series of simplified quality control procedures that are accessible to a wide range of preclinical imaging laboratories. Our intent is to provide minimum guidelines for routine quality control that can assist preclinical imaging specialists in setting up an appropriate quality control program for their facility.

  5. 21 CFR 111.105 - What must quality control personnel do?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 2 2011-04-01 2011-04-01 false What must quality control personnel do? 111.105... for Quality Control § 111.105 What must quality control personnel do? Quality control personnel must... manufacturing record. To do so, quality control personnel must perform operations that include: (a) Approving or...

  6. 42 CFR 493.643 - Fee for determination of program compliance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... laboratory's scope and volume of testing (excluding tests performed for quality control, quality assurance... procedure or examination for a single analyte. (Tests performed for quality control, quality assurance, and... HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS General Administration...

  7. Measuring Software Product Quality: The ISO 25000 Series and CMMI

    DTIC Science & Technology

    2004-06-14

    performance objectives” covers objectives and requirements for product quality, service quality , and process performance. Process performance objectives...such that product quality, service quality , and process performance attributes are measurable and controlled throughout the project (internal and

  8. Implementing self sustained quality control procedures in a clinical laboratory.

    PubMed

    Khatri, Roshan; K C, Sanjay; Shrestha, Prabodh; Sinha, J N

    2013-01-01

    Quality control is an essential component in every clinical laboratory which maintains the excellence of laboratory standards, supplementing to proper disease diagnosis, patient care and resulting in overall strengthening of health care system. Numerous quality control schemes are available, with combinations of procedures, most of which are tedious, time consuming and can be "too technical" whereas commercially available quality control materials can be expensive especially for laboratories in developing nations like Nepal. Here, we present a procedure performed at our centre with self prepared control serum and use of simple statistical tools for quality assurance. The pooled serum was prepared as per guidelines for preparation of stabilized liquid quality control serum from human sera. Internal Quality Assessment was performed on this sample, on a daily basis which included measurement of 12 routine biochemical parameters. The results were plotted on Levey-Jennings charts and analysed with quality control rules, for a period of one month. The mean levels of biochemical analytes in self prepared control serum were within normal physiological range. This serum was evaluated every day along with patients' samples. The results obtained were plotted on control charts and analysed using common quality control rules to identify possible systematic and random errors. Immediate mitigation measures were taken and the dispatch of erroneous reports was avoided. In this study we try to highlight on a simple internal quality control procedure which can be performed by laboratories, with minimum technology, expenditure, and expertise and improve reliability and validity of the test reports.

  9. 7 CFR 275.10 - Scope and purpose.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... to enhanced funding. (b) The objectives of quality control reviews are to provide: (1) A systematic... FOOD STAMP AND FOOD DISTRIBUTION PROGRAM PERFORMANCE REPORTING SYSTEM Quality Control (QC) Reviews... responsible for conducting quality control reviews. For food stamp quality control reviews, a sample of...

  10. Handling Qualities of Model Reference Adaptive Controllers with Varying Complexity for Pitch-Roll Coupled Failures

    NASA Technical Reports Server (NTRS)

    Schaefer, Jacob; Hanson, Curt; Johnson, Marcus A.; Nguyen, Nhan

    2011-01-01

    Three model reference adaptive controllers (MRAC) with varying levels of complexity were evaluated on a high performance jet aircraft and compared along with a baseline nonlinear dynamic inversion controller. The handling qualities and performance of the controllers were examined during failure conditions that induce coupling between the pitch and roll axes. Results from flight tests showed with a roll to pitch input coupling failure, the handling qualities went from Level 2 with the baseline controller to Level 1 with the most complex MRAC tested. A failure scenario with the left stabilator frozen also showed improvement with the MRAC. Improvement in performance and handling qualities was generally seen as complexity was incrementally added; however, added complexity usually corresponds to increased verification and validation effort required for certification. The tradeoff between complexity and performance is thus important to a controls system designer when implementing an adaptive controller on an aircraft. This paper investigates this relation through flight testing of several controllers of vary complexity.

  11. Multifamily Quality Control Inspector Job/Task Analysis and Report: September 2013

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Owens, C. M.

    The development of job/task analyses (JTAs) is one of three components of the Guidelines for Home Energy Professionals project and will allow industry to develop training resources, quality assurance protocols, accredited training programs, and professional certifications. The Multifamily Quality Control Inspector JTA identifies and catalogs all of the tasks performed by multifamily quality control inspectors, as well as the knowledge, skills, and abilities (KSAs) needed to perform the identified tasks.

  12. QUALITY CONTROLS FOR PCR

    EPA Science Inventory

    The purpose of this presentation is to present an overview of the quality control (QC) sections of a draft EPA document entitled, "Quality Assurance/Quality Control Guidance for Laboratories Performing PCR Analyses on Environmental Samples." This document has been prepared by th...

  13. Benchmarking to the world's best in mathematics. Quality control in curriculum and instruction among the top performers in the TIMSS.

    PubMed

    Phelps, R P

    2001-08-01

    This article describes the education quality control systems (for mathematics) used by those countries that performed best on the Third International Mathematics and Science Study (TIMSS). Enforced quality control measures are defined as "decision points"--where adherence to the curriculum and instruction system can be reinforced. Most decision points involve stakes for the student, teacher, or school. They involve potential consequences for failure to adhere to the system and to follow the program at a reasonable pace. Generally, countries with more decision points perform better on the TIMSS. When the number of decision points and TIMSS test scores are adjusted for country wealth, the relationship between the degree of (enforced) quality control and student achievement appears to be positive and exponential. The more (enforced) quality control measures employed in an education system, the greater is students' academic achievement.

  14. A semi-active suspension control algorithm for vehicle comprehensive vertical dynamics performance

    NASA Astrophysics Data System (ADS)

    Nie, Shida; Zhuang, Ye; Liu, Weiping; Chen, Fan

    2017-08-01

    Comprehensive performance of the vehicle, including ride qualities and road-holding, is essentially of great value in practice. Many up-to-date semi-active control algorithms improve vehicle dynamics performance effectively. However, it is hard to improve comprehensive performance for the conflict between ride qualities and road-holding around the second-order resonance. Hence, a new control algorithm is proposed to achieve a good trade-off between ride qualities and road-holding. In this paper, the properties of the invariant points are analysed, which gives an insight into the performance conflicting around the second-order resonance. Based on it, a new control algorithm is proposed. The algorithm employs a novel frequency selector to balance suspension ride and handling performance by adopting a medium damping around the second-order resonance. The results of this study show that the proposed control algorithm could improve the performance of ride qualities and suspension working space up to 18.3% and 8.2%, respectively, with little loss of road-holding compared to the passive suspension. Consequently, the comprehensive performance can be improved by 6.6%. Hence, the proposed algorithm is of great potential to be implemented in practice.

  15. 42 CFR 84.256 - Quality control requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Quality control requirements. 84.256 Section 84.256... § 84.256 Quality control requirements. (a) In addition to the construction and performance requirements specified in §§ 84.251, 84.252, 84.253, 84.254, and 84.255, the quality control requirements in paragraphs...

  16. 42 CFR 84.256 - Quality control requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Quality control requirements. 84.256 Section 84.256... § 84.256 Quality control requirements. (a) In addition to the construction and performance requirements specified in §§ 84.251, 84.252, 84.253, 84.254, and 84.255, the quality control requirements in paragraphs...

  17. 42 CFR 84.256 - Quality control requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Quality control requirements. 84.256 Section 84.256... § 84.256 Quality control requirements. (a) In addition to the construction and performance requirements specified in §§ 84.251, 84.252, 84.253, 84.254, and 84.255, the quality control requirements in paragraphs...

  18. 42 CFR 84.256 - Quality control requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Quality control requirements. 84.256 Section 84.256... § 84.256 Quality control requirements. (a) In addition to the construction and performance requirements specified in §§ 84.251, 84.252, 84.253, 84.254, and 84.255, the quality control requirements in paragraphs...

  19. 42 CFR 84.256 - Quality control requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Quality control requirements. 84.256 Section 84.256... § 84.256 Quality control requirements. (a) In addition to the construction and performance requirements specified in §§ 84.251, 84.252, 84.253, 84.254, and 84.255, the quality control requirements in paragraphs...

  20. 21 CFR 640.56 - Quality control test for potency.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... quality control test for potency may be performed by a clinical laboratory which meets the standards of... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Quality control test for potency. 640.56 Section...) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Cryoprecipitate § 640.56 Quality control...

  1. Image processing system performance prediction and product quality evaluation

    NASA Technical Reports Server (NTRS)

    Stein, E. K.; Hammill, H. B. (Principal Investigator)

    1976-01-01

    The author has identified the following significant results. A new technique for image processing system performance prediction and product quality evaluation was developed. It was entirely objective, quantitative, and general, and should prove useful in system design and quality control. The technique and its application to determination of quality control procedures for the Earth Resources Technology Satellite NASA Data Processing Facility are described.

  2. 40 CFR 428.95 - Standards of performance for new sources.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Mechanical Reclaimed Rubber Subcategory § 428.95 Standards of performance for new sources. (a) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled... or quality of pollutants or pollutant properties, controlled by this section and attributable to pan...

  3. Deliberate Practice Enhances Quality of Laparoscopic Surgical Performance in a Randomized Controlled Trial: from Arrested Development to Expert Performance

    PubMed Central

    Hashimoto, Daniel A.; Sirimanna, Pramudith; Gomez, Ernest D.; Beyer-Berjot, Laura; Ericsson, K. Anders; Williams, Noel N.; Darzi, Ara; Aggarwal, Rajesh

    2014-01-01

    Background This study investigated whether deliberate practice leads to an increase in surgical quality in virtual reality (VR) laparoscopic cholecystectomies (LC). Previous research has suggested that sustained DP is effective in surgical training. Methods Fourteen residents were randomized into deliberate practice (n=7) or control training (n=7). Both groups performed 10 sessions of two VR LCs. Each session, the DP group was assigned 30 minutes of DP activities in between LCs while the control group viewed educational videos or read journal articles. Performance was assessed on speed and dexterity; quality was rated with global (GRS) and procedure-specific (PSRS) rating scales. All participants then performed five porcine LCs. Results Both groups improved over 20 VR LCs in time, dexterity, and global rating scales (all p<0.05). After 20 LCs, there were no differences in speed or dexterity between groups. The DP group achieved higher quality of VR surgical performance than control for GRS (26 vs. 20, p=0.001) and PSRS (18 vs. 15, p=0.001). For VR cases, DP subjects plateaued at GRS=25 after 10 cases and control group at GRS=20 after five cases. At completion of VR training, 100% of the DP group reached target quality of performance (GRS≥21) compared to 30% in the control group. There were no significant differences for improvements in time or dexterity over five porcine LCs. Conclusion This study suggests that DP leads to higher quality performance in VR LC than standard training alone. Standard training may leave individuals in a state of “arrested development” compared to DP. PMID:25539697

  4. High perfomance liquid chromatography fingerprint analysis for quality control of brotowali (Tinospora crispa)

    NASA Astrophysics Data System (ADS)

    Syarifah, V. B.; Rafi, M.; Wahyuni, W. T.

    2017-05-01

    Brotowali (Tinospora crispa) is widely used in Indonesia as ingredient of herbal medicine formulation. To ensure the quality, safety, and efficacy of herbal medicine products, its chemical constituents should be continuously evaluated. High performance liquid chromatography (HPLC) fingerprint is one of powerful technique for this quality control process. In this study, HPLC fingerprint analysis method was developed for quality control of brotowali. HPLC analysis was performed in C18 column and detection was performed using photodiode array detector. The optimum mobile phase for brotowali fingerprint was acetonitrile (ACN) and 0.1% formic acid in gradient elution mode at a flow rate of 1 mL/min. The number of peaks detected in HPLC fingerprint of brotowali was 32 peaks and 23 peaks for stems and leaves, respectively. Berberine as marker compound was detected at retention time of 20.525 minutes. Evaluation of analytical performance including precision, reproducibility, and stability prove that this HPLC fingerprint analysis was reliable and could be applied for quality control of brotowali.

  5. Performance Evaluation of UPQC under Nonlinear Unbalanced Load Conditions Using Synchronous Reference Frame Based Control

    NASA Astrophysics Data System (ADS)

    Kota, Venkata Reddy; Vinnakoti, Sudheer

    2017-12-01

    Today, maintaining Power Quality (PQ) is very important in the growing competent world. With new equipments and devices, new challenges are also being put before power system operators. Unified Power Quality Conditioner (UPQC) is proposed to mitigate many power quality problems and to improve the performance of the power system. In this paper, an UPQC with Fuzzy Logic controller for capacitor voltage balancing is proposed in Synchronous Reference Frame (SRF) based control with Modified Phased Locked Loop (MPLL). The proposed controller with SRF-MPLL based control is tested under non-linear and unbalanced load conditions. The system is developed in Matlab/Simulink and its performance is analyzed under various conditions like non-linear, unbalanced load and polluted supply voltage including voltage sag/swells. Active and reactive power flow in the system, power factor and %THD of voltages and currents before and after compensation are also analyzed in this work. Results prove the applicability of the proposed scheme for power quality improvement. It is observed that the fuzzy controller gives better performance than PI controller with faster capacitor voltage balancing and also improves the dynamic performance of the system.

  6. A Total Quality-Control Plan with Right-Sized Statistical Quality-Control.

    PubMed

    Westgard, James O

    2017-03-01

    A new Clinical Laboratory Improvement Amendments option for risk-based quality-control (QC) plans became effective in January, 2016. Called an Individualized QC Plan, this option requires the laboratory to perform a risk assessment, develop a QC plan, and implement a QC program to monitor ongoing performance of the QC plan. Difficulties in performing a risk assessment may limit validity of an Individualized QC Plan. A better alternative is to develop a Total QC Plan including a right-sized statistical QC procedure to detect medically important errors. Westgard Sigma Rules provides a simple way to select the right control rules and the right number of control measurements. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Quality charters or quality members? A control theory perspective on team charters and team performance.

    PubMed

    Courtright, Stephen H; McCormick, Brian W; Mistry, Sal; Wang, Jiexin

    2017-10-01

    Though prevalent in practice, team charters have only recently received scholarly attention. However, most of this work has been relatively devoid of theory, and consequently, key questions about why and under what conditions team charter quality affects team performance remain unanswered. To address these gaps, we draw on macro organizational control theory to propose that team charter quality serves as a team-level "behavior" control mechanism that builds task cohesion through a structured exercise. We then juxtapose team charter quality with an "input" team control mechanism that influences the emergence of task cohesion more organically: team conscientiousness. Given their redundant effects on task cohesion, we propose that the effects of team charter quality and team conscientiousness on team performance (through task cohesion) are substitutive such that team charter quality primarily impacts team performance for teams that are low (vs. high) on conscientiousness. We test and find support for our hypotheses in a sample of 239 undergraduate self-managing project teams. Our study contributes to the groups and teams literature in the following ways: first, relative to previous studies, we take a more theory-driven approach toward understanding team charters, and in doing so, uncover when and why team charter quality impacts team performance; second, we integrate two normally disparate perspectives on team effectiveness (team development and team selection) to offer a broader perspective on how teams are "built"; and third, we introduce team charter quality as a performance-enhancing mechanism for teams lower on conscientiousness. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  8. Application of Sigma Metrics Analysis for the Assessment and Modification of Quality Control Program in the Clinical Chemistry Laboratory of a Tertiary Care Hospital.

    PubMed

    Iqbal, Sahar; Mustansar, Tazeen

    2017-03-01

    Sigma is a metric that quantifies the performance of a process as a rate of Defects-Per-Million opportunities. In clinical laboratories, sigma metric analysis is used to assess the performance of laboratory process system. Sigma metric is also used as a quality management strategy for a laboratory process to improve the quality by addressing the errors after identification. The aim of this study is to evaluate the errors in quality control of analytical phase of laboratory system by sigma metric. For this purpose sigma metric analysis was done for analytes using the internal and external quality control as quality indicators. Results of sigma metric analysis were used to identify the gaps and need for modification in the strategy of laboratory quality control procedure. Sigma metric was calculated for quality control program of ten clinical chemistry analytes including glucose, chloride, cholesterol, triglyceride, HDL, albumin, direct bilirubin, total bilirubin, protein and creatinine, at two control levels. To calculate the sigma metric imprecision and bias was calculated with internal and external quality control data, respectively. The minimum acceptable performance was considered as 3 sigma. Westgard sigma rules were applied to customize the quality control procedure. Sigma level was found acceptable (≥3) for glucose (L2), cholesterol, triglyceride, HDL, direct bilirubin and creatinine at both levels of control. For rest of the analytes sigma metric was found <3. The lowest value for sigma was found for chloride (1.1) at L2. The highest value of sigma was found for creatinine (10.1) at L3. HDL was found with the highest sigma values at both control levels (8.8 and 8.0 at L2 and L3, respectively). We conclude that analytes with the sigma value <3 are required strict monitoring and modification in quality control procedure. In this study application of sigma rules provided us the practical solution for improved and focused design of QC procedure.

  9. 77 FR 73611 - Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-11

    ...: Negative Quality Control Review Schedule. OMB Control Number: 0584-0034. Summary of Collection: The legislative basis for the operation of the quality control system is provided by section 16 of the Food and Nutrition Act of 2008. State agencies are required to perform Quality Control (QC) reviews for the...

  10. Analysis of Aircraft Control Performance using a Fuzzy Rule Base Representation of the Cooper-Harper Aircraft Handling Quality Rating

    NASA Technical Reports Server (NTRS)

    Tseng, Chris; Gupta, Pramod; Schumann, Johann

    2006-01-01

    The Cooper-Harper rating of Aircraft Handling Qualities has been adopted as a standard for measuring the performance of aircraft since it was introduced in 1966. Aircraft performance, ability to control the aircraft, and the degree of pilot compensation needed are three major key factors used in deciding the aircraft handling qualities in the Cooper- Harper rating. We formulate the Cooper-Harper rating scheme as a fuzzy rule-based system and use it to analyze the effectiveness of the aircraft controller. The automatic estimate of the system-level handling quality provides valuable up-to-date information for diagnostics and vehicle health management. Analyzing the performance of a controller requires a set of concise design requirements and performance criteria. Ir, the case of control systems fm a piloted aircraft, generally applicable quantitative design criteria are difficult to obtain. The reason for this is that the ultimate evaluation of a human-operated control system is necessarily subjective and, with aircraft, the pilot evaluates the aircraft in different ways depending on the type of the aircraft and the phase of flight. In most aerospace applications (e.g., for flight control systems), performance assessment is carried out in terms of handling qualities. Handling qualities may be defined as those dynamic and static properties of a vehicle that permit the pilot to fully exploit its performance in a variety of missions and roles. Traditionally, handling quality is measured using the Cooper-Harper rating and done subjectively by the human pilot. In this work, we have formulated the rules of the Cooper-Harper rating scheme as fuzzy rules with performance, control, and compensation as the antecedents, and pilot rating as the consequent. Appropriate direct measurements on the controller are related to the fuzzy Cooper-Harper rating system: a stability measurement like the rate of change of the cost function can be used as an indicator if the aircraft is under control; the tracking error is a good measurement for performance needed in the rating scheme. Finally, the change of the control amount or the output of a confidence tool, which has been developed by the authors, can be used as an indication of pilot compensation. We use a number of known aircraft flight scenarios with known pilot ratings to calibrate our fuzzy membership functions. These include normal flight conditions and situations in which partial or complete failure of tail, aileron, engine, or throttle occurs.

  11. ITS data quality control and the calculation of mobility performance measures

    DOT National Transportation Integrated Search

    2000-09-01

    This report describes the results of research on the use of intelligent transportation system (ITS) data in calculating mobility performance measures for ITS operations. The report also describes a data quality control process developed for the Trans...

  12. 7 CFR 275.10 - Scope and purpose.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... FOOD STAMP AND FOOD DISTRIBUTION PROGRAM PERFORMANCE REPORTING SYSTEM Quality Control (QC) Reviews... responsible for conducting quality control reviews. For food stamp quality control reviews, a sample of... terminated (called negative cases). Reviews shall be conducted on active cases to determine if households are...

  13. Flight-Test Validation and Flying Qualities Evaluation of a Rotorcraft UAV Flight Control System

    NASA Technical Reports Server (NTRS)

    Mettler, Bernard; Tuschler, Mark B.; Kanade, Takeo

    2000-01-01

    This paper presents a process of design and flight-test validation and flying qualities evaluation of a flight control system for a rotorcraft-based unmanned aerial vehicle (RUAV). The keystone of this process is an accurate flight-dynamic model of the aircraft, derived by using system identification modeling. The model captures the most relevant dynamic features of our unmanned rotorcraft, and explicitly accounts for the presence of a stabilizer bar. Using the identified model we were able to determine the performance margins of our original control system and identify limiting factors. The performance limitations were addressed and the attitude control system was 0ptimize.d for different three performance levels: slow, medium, fast. The optimized control laws will be implemented in our RUAV. We will first determine the validity of our control design approach by flight test validating our optimized controllers. Subsequently, we will fly a series of maneuvers with the three optimized controllers to determine the level of flying qualities that can be attained. The outcome enable us to draw important conclusions on the flying qualities requirements for small-scale RUAVs.

  14. QUALITY ASSURANCE AND QUALITY CONTROL FOR WASTE CONTAINMENT FACILITIES. Project Summary

    EPA Science Inventory

    It is generally agreed that both quality assurance (QA) and quality control (QC) are essential to the proper installation and eventual performance of environmentally safe and secure waste containment systems. Even further, there are both manufacturing and construction aspects to...

  15. Survey of the prevalence and methodology of quality assurance for B-mode ultrasound image quality among veterinary sonographers.

    PubMed

    Hoscheit, Larry P; Heng, Hock Gan; Lim, Chee Kin; Weng, Hsin-Yi

    2018-05-01

    Image quality in B-mode ultrasound is important as it reflects the diagnostic accuracy and diagnostic information provided during clinical scanning. Quality assurance programs for B-mode ultrasound systems/components are comprised of initial quality acceptance testing and subsequent regularly scheduled quality control testing. The importance of quality assurance programs for B-mode ultrasound image quality using ultrasound phantoms is well documented in the human medical and medical physics literature. The purpose of this prospective, cross-sectional, survey study was to determine the prevalence and methodology of quality acceptance testing and quality control testing of image quality for ultrasound system/components among veterinary sonographers. An online electronic survey was sent to 1497 members of veterinary imaging organizations: the American College of Veterinary Radiology, the Veterinary Ultrasound Society, and the European Association of Veterinary Diagnostic Imaging, and a total of 167 responses were received. The results showed that the percentages of veterinary sonographers performing quality acceptance testing and quality control testing are 42% (64/151; 95% confidence interval 34-52%) and 26% (40/156: 95% confidence interval 19-33%) respectively. Of the respondents who claimed to have quality acceptance testing or quality control testing of image quality in place for their ultrasound system/components, 0% have performed quality acceptance testing or quality control testing correctly (quality acceptance testing 95% confidence interval: 0-6%, quality control testing 95% confidence interval: 0-11%). Further education and guidelines are recommended for veterinary sonographers in the area of quality acceptance testing and quality control testing for B-mode ultrasound equipment/components. © 2018 American College of Veterinary Radiology.

  16. The model of flood control using servqual method and importance performance analysis in Surakarta City – Indonesia

    NASA Astrophysics Data System (ADS)

    Titi Purwantini, V.; Sutanto, Yusuf

    2018-05-01

    This research is to create a model of flood control in the city of Surakarta using Servqual method and Importance Performance Analysis. Service quality is generally defined as the overall assessment of a service by the customersor the extent to which a service meets customer’s needs or expectations. The purpose of this study is to find the first model of flood control that is appropriate to the condition of the community. Surakarta This means looking for a model that can provide satisfactory service for the people of Surakarta who are in the location of the flood. The second is to find the right model to improve service performance of Surakarta City Government in serving the people in flood location. The method used to determine the satisfaction of the public on the quality of service is to see the difference in the quality of service expected by the community with the reality. This method is Servqual Method While to assess the performance of city government officials is by comparing the actual performance with the quality of services provided, this method is This means looking for a model that can provide satisfactory service for the people of Surakarta who are in the location of the flood.The second is to find the right model to improve service performance of Surakarta City Government in serving the people in flood location. The method used to determine the satisfaction of the public on the quality of service is to see the difference in the quality of service expected by the community with the reality. This method is Servqual Method While to assess the performance of city government officials is by comparing the actual performance with the quality of services provided, this method is Importance Performance Analysis. Samples were people living in flooded areas in the city of Surakarta. Result this research is Satisfaction = Responsiveness+ Realibility + Assurance + Empathy+ Tangible (Servqual Model) and Importance Performance Analysis is From Cartesian diagram can be made Flood Control Formula as follow: Food Control = High performance

  17. Advances in traffic data collection and management : white paper.

    DOT National Transportation Integrated Search

    2003-01-31

    This white paper identifies innovative approaches for improving data quality through Quality Control. Quality Control emphasizes good data by ensuring selection of the most accurate detector then optimizing detector system performance. This is contra...

  18. 77 FR 75968 - Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-26

    ... information unless it displays a currently valid OMB control number. Food and Nutrition Service Title: Quality... required to perform Quality Control (QC) review for the Supplemental Nutrition Assistance Program (SNAP). The FNS-380-1, Quality Control Review Schedule is for State use to collect both QC data and case...

  19. [Evaluation of quality of HIV diagnostic procedures in Poland].

    PubMed

    Parczewski, Miłosz; Madaliński, Kazimierz; Leszczyszyn-Pynka, Magdalena; Boroń-Kaczmarska, Anna

    2010-01-01

    The aim of this work was quality assessment of HIV diagnostic procedures in Poland, including human and technical resources as well as laboratory practice. Sixty questionnaires were distributed among diagnostic centers to obtain qualitative data. Basing on the survey data serological control using coded panels of HIV-1/2 samples was performed. Thirty-one filled questionnaires were received (50.8%). Surveyed laboratories perform from 350 to 5500 serological screening tests per year. In most of laboratories fourth generation assays are available, while Blood Donation Centers screen the blood both with serological assays and by HIV-RNA detection. Sanitary and Epidemiological Stations and academic laboratories hold the ISO/IEC 17025 or IS0 9001:2001 accreditation, five of the surveyed centers participate in Labquality assurance and two in Quality Control in Molecular Diagnostics programs. Data of control serological testing were received from 21 centers. In the quality control assessment 194 analyses were performed with 91 true negative, 2 false negative, 96 true positive and 5 false positive results. False negative rate of % and false positive rate of 5.2% was noted for this study. Currently, virtually no guidelines related to the HIV-diagnostics quality assurance and control in Poland are in delineated. Development of the national unified quality control system, basing on the central institution is highly desirable. National certification within the frames of the quality control and assurance program should be mandatory for all the diagnostic labs, and aim at improvement of reliability of the result distributed among clinicians and patients.

  20. The meat quality and growth performance in broiler chickens fed diet with cinnamon powder.

    PubMed

    Sang-Oh, Park; Chae-Min, Ryu; Byung-Sung, Park; Jong, Hwangbo

    2013-01-01

    The aim of the study was to investigate the feeding effect of diets containing 3, 5 and 7% of cinnamon powder on meat quality and growth performance in broiler chickens. The chicken meat quality and growth performance in broiler chickens fed diets containing cinnamon powder increased significantly (P < 0.05) when compared to the control group. However, the TBARS of the meat of chickens fed diets containing cinnamon powder decreased significantly (P < 0.05) when compared to the control group. These findings suggest that the cinnamon powder can improve the shelf life and quality of chicken meat with maximize the productivity of broiler chickens.

  1. Educational Auditing and Quality Assurance. Occasional Paper No. 4.

    ERIC Educational Resources Information Center

    Conner, James E.; Lessinger, Leon M.

    This paper considers how to respond to new requirements for adequate disclosure of the schools' performance to the public. It proposes the use of three powerful constructs--quality control, quality assurance, and an independent educational accomplishment audit (IEAA). The essential elements of quality control are agreeing on and specifying desired…

  2. Applying Sigma Metrics to Reduce Outliers.

    PubMed

    Litten, Joseph

    2017-03-01

    Sigma metrics can be used to predict assay quality, allowing easy comparison of instrument quality and predicting which tests will require minimal quality control (QC) rules to monitor the performance of the method. A Six Sigma QC program can result in fewer controls and fewer QC failures for methods with a sigma metric of 5 or better. The higher the number of methods with a sigma metric of 5 or better, the lower the costs for reagents, supplies, and control material required to monitor the performance of the methods. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Autonomy and control in dyads: effects on interaction quality and joint creative performance.

    PubMed

    Weinstein, Netta; Hodgins, Holley S; Ryan, Richard M

    2010-12-01

    Two studies examined interaction quality and joint performance on two creative tasks in unacquainted dyads primed for autonomy or control orientations. It was hypothesized that autonomy-primed dyads would interact more constructively, experience more positive mood, and engage the task more readily, and as a result these dyads would perform better. To test this, Study 1 primed orientation and explored verbal creative performance on the Remote Associates Task (RAT). In Study 2, dyads were primed with autonomy and control orientation and videotaped during two joint creative tasks, one verbal (RAT) and one nonverbal (charades). Videotapes were coded for behavioral indicators of closeness and task engagement. Results showed that autonomy-primed dyads felt closer, were more emotionally and cognitively attuned, provided empathy and encouragement to partners, and performed more effectively. The effects of primed autonomy on creative performance were mediated by interpersonal quality, mood, and joint engagement.

  4. MATLAB Simulation of UPQC for Power Quality Mitigation Using an Ant Colony Based Fuzzy Control Technique

    PubMed Central

    Kumarasabapathy, N.; Manoharan, P. S.

    2015-01-01

    This paper proposes a fuzzy logic based new control scheme for the Unified Power Quality Conditioner (UPQC) for minimizing the voltage sag and total harmonic distortion in the distribution system consequently to improve the power quality. UPQC is a recent power electronic module which guarantees better power quality mitigation as it has both series-active and shunt-active power filters (APFs). The fuzzy logic controller has recently attracted a great deal of attention and possesses conceptually the quality of the simplicity by tackling complex systems with vagueness and ambiguity. In this research, the fuzzy logic controller is utilized for the generation of reference signal controlling the UPQC. To enable this, a systematic approach for creating the fuzzy membership functions is carried out by using an ant colony optimization technique for optimal fuzzy logic control. An exhaustive simulation study using the MATLAB/Simulink is carried out to investigate and demonstrate the performance of the proposed fuzzy logic controller and the simulation results are compared with the PI controller in terms of its performance in improving the power quality by minimizing the voltage sag and total harmonic distortion. PMID:26504895

  5. Multicriteria Gain Tuning for Rotorcraft Flight Controls (also entitled The Development of the Conduit Advanced Control System Design and Evaluation Interface with a Case Study Application Fly by Wire Helicopter Design)

    NASA Technical Reports Server (NTRS)

    Biezad, Daniel

    1997-01-01

    Handling qualities analysis and control law design would seem to be naturally complimenting components of aircraft flight control system design, however these two closely coupled disciplines are often not well integrated in practice. Handling qualities engineers and control system engineers may work in separate groups within an aircraft company. Flight control system engineers and handling quality specialists may come from different backgrounds and schooling and are often not aware of the other group's research. Thus while the handling qualities specifications represent desired aircraft response characteristics, these are rarely incorporated directly in the control system design process. Instead modem control system design techniques are based on servo-loop robustness specifications, and simple representations of the desired control response. Comprehensive handling qualities analysis is often left until the end of the design cycle and performed as a check of the completed design for satisfactory performance. This can lead to costly redesign or less than satisfactory aircraft handling qualities when the flight testing phase is reached. The desire to integrate the fields of handling qualities and flight,control systems led to the development of the CONDUIT system. This tool facilitates control system designs that achieve desired handling quality requirements and servo-loop specifications in a single design process. With CONDUIT, the control system engineer is now able to directly design and control systems to meet the complete handling specifications. CONDUIT allows the designer to retain a preferred control law structure, but then tunes the system parameters to meet the handling quality requirements.

  6. Development and implementation of an automated quantitative film digitizer quality control program

    NASA Astrophysics Data System (ADS)

    Fetterly, Kenneth A.; Avula, Ramesh T. V.; Hangiandreou, Nicholas J.

    1999-05-01

    A semi-automated, quantitative film digitizer quality control program that is based on the computer analysis of the image data from a single digitized test film was developed. This program includes measurements of the geometric accuracy, optical density performance, signal to noise ratio, and presampled modulation transfer function. The variability of the measurements was less than plus or minus 5%. Measurements were made on a group of two clinical and two laboratory laser film digitizers during a trial period of approximately four months. Quality control limits were established based on clinical necessity, vendor specifications and digitizer performance. During the trial period, one of the digitizers failed the performance requirements and was corrected by calibration.

  7. Assessing Subjectivity in Sensor Data Post Processing via a Controlled Experiment

    NASA Astrophysics Data System (ADS)

    Jones, A. S.; Horsburgh, J. S.; Eiriksson, D.

    2017-12-01

    Environmental data collected by in situ sensors must be reviewed to verify validity, and conducting quality control often requires making edits in post processing to generate approved datasets. This process involves decisions by technicians, data managers, or data users on how to handle problematic data. Options include: removing data from a series, retaining data with annotations, and altering data based on algorithms related to adjacent data points or the patterns of data at other locations or of other variables. Ideally, given the same dataset and the same quality control guidelines, multiple data quality control technicians would make the same decisions in data post processing. However, despite the development and implementation of guidelines aimed to ensure consistent quality control procedures, we have faced ambiguity when performing post processing, and we have noticed inconsistencies in the practices of individuals performing quality control post processing. Technicians with the same level of training and using the same input datasets may produce different results, affecting the overall quality and comparability of finished data products. Different results may also be produced by technicians that do not have the same level of training. In order to assess the effect of subjective decision making by the individual technician on the end data product, we designed an experiment where multiple users performed quality control post processing on the same datasets using a consistent set of guidelines, field notes, and tools. We also assessed the effect of technician experience and training by conducting the same procedures with a group of novices unfamiliar with the data and the quality control process and compared their results to those generated by a group of more experienced technicians. In this presentation, we report our observations of the degree of subjectivity in sensor data post processing, assessing and quantifying the impacts of individual technician as well as technician experience on quality controlled data products.

  8. Internal quality assurance in a clinical virology laboratory. II. Internal quality control.

    PubMed Central

    Gray, J J; Wreghitt, T G; McKee, T A; McIntyre, P; Roth, C E; Smith, D J; Sutehall, G; Higgins, G; Geraghty, R; Whetstone, R

    1995-01-01

    AIMS--In April 1991 additional quality control procedures were introduced into the virology section of the Clinical Microbiology and Public Health Laboratory, Cambridge. Internal quality control (IQC) samples were gradually included in the serological assays performed in the laboratory and supplemented kit controls and standard sera. METHODS--From April 1991 to December 1993, 2421 IQC procedures were carried out with reference sera. RESULTS--The IQC samples were evaluated according to the Westgard rules. Violations were recorded in 60 of 1808 (3.3%) controls and were highest in the IQC samples of complement fixation tests (25/312 (8%) of controls submitted for complement fixation tests). CONCLUSIONS--The inclusion of IQC samples in the serological assays performed in the laboratory has highlighted batch to batch variation in commercial assays. The setting of acceptable limits for the IQC samples has increased confidence in the validity of assay results. PMID:7730475

  9. The influence of personal qualities on performance and progression in a pre-registration nursing programme.

    PubMed

    Pitt, Victoria; Powis, David; Levett-Jones, Tracy; Hunter, Sharyn

    2014-05-01

    Research conducted primarily with psychology and medical students has highlighted that personal qualities play an important role in students' academic performance. In nursing there has been limited investigation of the relationship between personal qualities and performance. Yet, reports of student incivility and a lack of compassion have prompted appeals to integrate the assessment of personal qualities into pre-registration nursing student selection. Before this can be done research is needed to explore the influence of students' personal qualities on programme performance and progression. This study explores the relationships between students' personal qualities and their academic and clinical performance, behaviours and progression through a pre-registration nursing programme in Australia. This longitudinal descriptive correlational study was undertaken with a sample of Australian pre-registration nursing students (n=138). Students' personal qualities were assessed using three personal qualities assessment (PQA) instruments. Outcome measures included grades in nursing theory and clinical courses, yearly grade point average, final clinical competency, progression (completion), class attendance and levels of life event stress. Significant correlations were found between academic performance and PQA scores for self-control, resilience and traits of aloofness, confidence and involvement. Final clinical competence was predicted by confidence and self-control scores. Students with higher empathy had higher levels of life event stress in their first year and class attendance had a positive correlation with self-control. Completing the programme in three years was weakly predicted by the measure of resilience. No difference was noted between extreme or non-extreme scorers on the PQA scales with respect to performance or progression. This sample of students' personal qualities was found to influence their academic and clinical performance and their ability to complete a pre-registration programme in three years. However, further research is required with larger cohorts to confirm the use of personal qualities assessment during selection. © 2013.

  10. Chronic Low Quality Sleep Impairs Postural Control in Healthy Adults.

    PubMed

    Furtado, Fabianne; Gonçalves, Bruno da Silva B; Abranches, Isabela Lopes Laguardia; Abrantes, Ana Flávia; Forner-Cordero, Arturo

    2016-01-01

    The lack of sleep, both in quality and quantity, is an increasing problem in modern society, often related to workload and stress. A number of studies have addressed the effects of acute (total) sleep deprivation on postural control. However, up to date, the effects of chronic sleep deficits, either in quantity or quality, have not been analyzed. Thirty healthy adults participated in the study that consisted of registering activity with a wrist actigraph for more than a week before performing a series of postural control tests. Sleep and circadian rhythm variables were correlated and the sum of activity of the least active 5-h period, L5, a rhythm variable, obtained the greater coefficient value with sleep quality variables (wake after sleep onset WASO and efficiency sleep). Cluster analysis was performed to classify subjects into two groups based on L5 (low and high). The balance tests scores used to asses postural control were measured using Biodex Balance System and were compared between the two groups with different sleep quality. The postural tests were divided into dynamic (platform tilt with eyes open, closed and cursor) and static (clinical test of sensory integration). The results showed that during the tests with eyes closed, the group with worse sleep quality had also worse postural control performance. Lack of vision impairs postural balance more deeply in subjects with chronic sleep inefficiency. Chronic poor sleep quality impairs postural control similarly to total sleep deprivation.

  11. Chronic Low Quality Sleep Impairs Postural Control in Healthy Adults

    PubMed Central

    Gonçalves, Bruno da Silva B.; Abranches, Isabela Lopes Laguardia; Abrantes, Ana Flávia

    2016-01-01

    The lack of sleep, both in quality and quantity, is an increasing problem in modern society, often related to workload and stress. A number of studies have addressed the effects of acute (total) sleep deprivation on postural control. However, up to date, the effects of chronic sleep deficits, either in quantity or quality, have not been analyzed. Thirty healthy adults participated in the study that consisted of registering activity with a wrist actigraph for more than a week before performing a series of postural control tests. Sleep and circadian rhythm variables were correlated and the sum of activity of the least active 5-h period, L5, a rhythm variable, obtained the greater coefficient value with sleep quality variables (wake after sleep onset WASO and efficiency sleep). Cluster analysis was performed to classify subjects into two groups based on L5 (low and high). The balance tests scores used to asses postural control were measured using Biodex Balance System and were compared between the two groups with different sleep quality. The postural tests were divided into dynamic (platform tilt with eyes open, closed and cursor) and static (clinical test of sensory integration). The results showed that during the tests with eyes closed, the group with worse sleep quality had also worse postural control performance. Lack of vision impairs postural balance more deeply in subjects with chronic sleep inefficiency. Chronic poor sleep quality impairs postural control similarly to total sleep deprivation. PMID:27732604

  12. Greenhouse production of Impatiens wallerana using a controlled-release fertiliser produces quality finished plants with enhanced garden performance

    USDA-ARS?s Scientific Manuscript database

    Nutrient management during production can greatly influence post-production quality of plants. The objective of this research was to evaluate the effect of controlled release fertilizer (CRF) applied at the time of plug planting on the garden performance (post-production) of impatiens (Impatiens wal...

  13. A proteomics performance standard to support measurement quality in proteomics.

    PubMed

    Beasley-Green, Ashley; Bunk, David; Rudnick, Paul; Kilpatrick, Lisa; Phinney, Karen

    2012-04-01

    The emergence of MS-based proteomic platforms as a prominent technology utilized in biochemical and biomedical research has increased the need for high-quality MS measurements. To address this need, National Institute of Standards and Technology (NIST) reference material (RM) 8323 yeast protein extract is introduced as a proteomics quality control material for benchmarking the preanalytical and analytical performance of proteomics-based experimental workflows. RM 8323 yeast protein extract is based upon the well-characterized eukaryote Saccharomyces cerevisiae and can be utilized in the design and optimization of proteomics-based methodologies from sample preparation to data analysis. To demonstrate its utility as a proteomics quality control material, we coupled LC-MS/MS measurements of RM 8323 with the NIST MS Quality Control (MSQC) performance metrics to quantitatively assess the LC-MS/MS instrumentation parameters that influence measurement accuracy, repeatability, and reproducibility. Due to the complexity of the yeast proteome, we also demonstrate how NIST RM 8323, along with the NIST MSQC performance metrics, can be used in the evaluation and optimization of proteomics-based sample preparation methods. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Internal quality control in serological tests for syphilis.

    PubMed Central

    Wasley, G D

    1985-01-01

    The importance of syphilis serological tests demands that laboratory reports are reliable. Internal quality control applied to the organisation of a syphilis serology service improves laboratory bench performance and reporting. Described here are internal quality control procedures of a department that serves a genitourinary medicine clinic and conducts 70 000 tests a year to investigate for syphilis. PMID:3884487

  15. Quality control/quality assurance testing for joint density and segregation of asphalt mixtures.

    DOT National Transportation Integrated Search

    2013-04-01

    Longitudinal joint quality control/assurance is essential to the successful performance of asphalt pavements and it has received considerable amount of attention in recent years. The purpose of the study is to evaluate the level of compaction at the ...

  16. Low dynamic muscle strength and its associations with fatigue, functional performance, and quality of life in premenopausal patients with systemic lupus erythematosus and low disease activity: a case–control study

    PubMed Central

    2013-01-01

    Background The purpose of the present study was to compare dynamic muscle strength, functional performance, fatigue, and quality of life in premenopausal systemic lupus erythematosus (SLE) patients with low disease activity versus matched-healthy controls and to determine the association of dynamic muscle strength with fatigue, functional performance, and quality of life in SLE patients. Methods We evaluated premenopausal (18–45 years) SLE patients with low disease activity (Systemic lupus erythematosus disease activity index [SLEDAI]: mean 1.5 ± 1.2). The control (n = 25) and patient (n = 25) groups were matched by age, physical characteristics, and the level of physical activities in daily life (International Physical Activity Questionnaire IPAQ). Both groups had not participated in regular exercise programs for at least six months prior to the study. Dynamic muscle strength was assessed by one-repetition maximum (1-RM) tests. Functional performance was assessed by the Timed Up and Go (TUG), in 30-s test a chair stand and arm curl using a 2-kg dumbbell and balance test, handgrip strength and a sit-and-reach flexibility test. Quality of life (SF-36) and fatigue were also measured. Results The SLE patients showed significantly lower dynamic muscle strength in all exercises (leg press 25.63%, leg extension 11.19%, leg curl 15.71%, chest press 18.33%, lat pulldown 13.56%, 1-RM total load 18.12%, P < 0.001-0.02) compared to the controls. The SLE patients also had lower functional performance, greater fatigue and poorer quality of life. In addition, fatigue, SF-36 and functional performance accounted for 52% of the variance in dynamic muscle strength in the SLE patients. Conclusions Premenopausal SLE patients with low disease activity showed lower dynamic muscle strength, along with increased fatigue, reduced functional performance, and poorer quality of life when compared to matched controls. PMID:24011222

  17. Instrumental Surveillance of Water Quality.

    ERIC Educational Resources Information Center

    Miller, J. A.; And Others

    The role analytical instrumentation performs in the surveillance and control of the quality of water resources is reviewed. Commonly performed analyses may range from simple tests for physical parameters to more highly sophisticated radiological or spectrophotometric methods. This publication explores many of these types of water quality analyses…

  18. Quality Control for Interviews to Obtain Dietary Recalls from Children for Research Studies

    PubMed Central

    SHAFFER, NICOLE M.; THOMPSON, WILLIAM O.; BAGLIO, MICHELLE L.; GUINN, CAROLINE H.; FRYE, FRANCESCA H. A.

    2005-01-01

    Quality control is an important aspect of a study because the quality of data collected provides a foundation for the conclusions drawn from the study. For studies that include interviews, establishing quality control for interviews is critical in ascertaining whether interviews are conducted according to protocol. Despite the importance of quality control for interviews, few studies adequately document the quality control procedures used during data collection. This article reviews quality control for interviews and describes methods and results of quality control for interviews from two of our studies regarding the accuracy of children's dietary recalls; the focus is on quality control regarding interviewer performance during the interview, and examples are provided from studies with children. For our two studies, every interview was audio recorded and transcribed. The audio recording and typed transcript from one interview conducted by each research dietitian either weekly or daily were randomly selected and reviewed by another research dietitian, who completed a standardized quality control for interviews checklist. Major strengths of the methods of quality control for interviews in our two studies include: (a) interviews obtained for data collection were randomly selected for quality control for interviews, and (b) quality control for interviews was assessed on a regular basis throughout data collection. The methods of quality control for interviews described may help researchers design appropriate methods of quality control for interviews for future studies. PMID:15389417

  19. Academic Quality Control in Nigerian Universities: Exploring Lecturers' Perceptions

    ERIC Educational Resources Information Center

    Obiekezie, E. O.; Ejemot-Nwadiaro, R. I.; Essien, M. I.; Timothy, A. Essien

    2014-01-01

    The level of job performance, international comparability and competitiveness of Nigerian university graduates are burning issues. Consequently, the academic quality of Nigerian universities has come under severe criticism. Since university lecturers are key players in quality control in universities, this study explored their perceptions of…

  20. An Overview of Controls and Flying Qualities Technology on the F/A-18 High Alpha Research Vehicle

    NASA Technical Reports Server (NTRS)

    Pahle, Joseph W.; Wichman, Keith D.; Foster, John V.; Bundick, W. Thomas

    1996-01-01

    The NASA F/A-18 High Alpha Research Vehicle (HARV) has been the flight test bed of a focused technology effort to significantly increase maneuvering capability at high angles of attack. Development and flight test of control law design methodologies, handling qualities metrics, performance guidelines, and flight evaluation maneuvers are described. The HARV has been modified to include two research control effectors, thrust vectoring, and actuated forebody strakes in order to provide increased control power at high angles of attack. A research flight control system has been used to provide a flexible, easily modified capability for high-angle-of-attack research controls. Different control law design techniques have been implemented and flight-tested, including eigenstructure assignment, variable gain output feedback, pseudo controls, and model-following. Extensive piloted simulation has been used to develop nonlinear performance guide-lines and handling qualities criteria for high angles of attack. This paper reviews the development and evaluation of technologies useful for high-angle-of-attack control. Design, development, and flight test of the research flight control system, control laws, flying qualities specifications, and flight test maneuvers are described. Flight test results are used to illustrate some of the lessons learned during flight test and handling qualities evaluations.

  1. Neural Network based Control of SG based Standalone Generating System with Energy Storage for Power Quality Enhancement

    NASA Astrophysics Data System (ADS)

    Nayar, Priya; Singh, Bhim; Mishra, Sukumar

    2017-08-01

    An artificial intelligence based control algorithm is used in solving power quality problems of a diesel engine driven synchronous generator with automatic voltage regulator and governor based standalone system. A voltage source converter integrated with a battery energy storage system is employed to mitigate the power quality problems. An adaptive neural network based signed regressor control algorithm is used for the estimation of the fundamental component of load currents for control of a standalone system with load leveling as an integral feature. The developed model of the system performs accurately under varying load conditions and provides good dynamic response to the step changes in loads. The real time performance is achieved using MATLAB along with simulink/simpower system toolboxes and results adhere to an IEEE-519 standard for power quality enhancement.

  2. An approach to quality and performance control in a computer-assisted clinical chemistry laboratory.

    PubMed Central

    Undrill, P E; Frazer, S C

    1979-01-01

    A locally developed, computer-based clinical chemistry laboratory system has been in operation since 1970. This utilises a Digital Equipment Co Ltd PDP 12 and an interconnected PDP 8/F computer. Details are presented of the performance and quality control techniques incorporated into the system. Laboratory performance is assessed through analysis of results from fixed-level control sera as well as from cumulative sum methods. At a simple level the presentation may be considered purely indicative, while at a more sophisticated level statistical concepts have been introduced to aid the laboratory controller in decision-making processes. PMID:438340

  3. Face Recognition for Access Control Systems Combining Image-Difference Features Based on a Probabilistic Model

    NASA Astrophysics Data System (ADS)

    Miwa, Shotaro; Kage, Hiroshi; Hirai, Takashi; Sumi, Kazuhiko

    We propose a probabilistic face recognition algorithm for Access Control System(ACS)s. Comparing with existing ACSs using low cost IC-cards, face recognition has advantages in usability and security that it doesn't require people to hold cards over scanners and doesn't accept imposters with authorized cards. Therefore face recognition attracts more interests in security markets than IC-cards. But in security markets where low cost ACSs exist, price competition is important, and there is a limitation on the quality of available cameras and image control. Therefore ACSs using face recognition are required to handle much lower quality images, such as defocused and poor gain-controlled images than high security systems, such as immigration control. To tackle with such image quality problems we developed a face recognition algorithm based on a probabilistic model which combines a variety of image-difference features trained by Real AdaBoost with their prior probability distributions. It enables to evaluate and utilize only reliable features among trained ones during each authentication, and achieve high recognition performance rates. The field evaluation using a pseudo Access Control System installed in our office shows that the proposed system achieves a constant high recognition performance rate independent on face image qualities, that is about four times lower EER (Equal Error Rate) under a variety of image conditions than one without any prior probability distributions. On the other hand using image difference features without any prior probabilities are sensitive to image qualities. We also evaluated PCA, and it has worse, but constant performance rates because of its general optimization on overall data. Comparing with PCA, Real AdaBoost without any prior distribution performs twice better under good image conditions, but degrades to a performance as good as PCA under poor image conditions.

  4. External Quality Control Review of the Defense Information Systems Agency Audit Organization

    DTIC Science & Technology

    2012-08-07

    We are providing this report for your information and use. We have reviewed the system of quality control for the audit organization of the Defense...audit organization encompasses the audit organization’s leadership, emphasis on performing high quality work, and policies and procedures established

  5. 7 CFR 90.102 - Quality assurance review.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... INTRODUCTION Quality Assurance § 90.102 Quality assurance review. (a) Each laboratory performing tests and... review of the adequacy of quality control measures taken by the laboratory for the standardized method of...

  6. 7 CFR 90.102 - Quality assurance review.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... INTRODUCTION Quality Assurance § 90.102 Quality assurance review. (a) Each laboratory performing tests and... review of the adequacy of quality control measures taken by the laboratory for the standardized method of...

  7. 7 CFR 90.102 - Quality assurance review.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... INTRODUCTION Quality Assurance § 90.102 Quality assurance review. (a) Each laboratory performing tests and... review of the adequacy of quality control measures taken by the laboratory for the standardized method of...

  8. 7 CFR 90.102 - Quality assurance review.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... INTRODUCTION Quality Assurance § 90.102 Quality assurance review. (a) Each laboratory performing tests and... review of the adequacy of quality control measures taken by the laboratory for the standardized method of...

  9. Furthering the quality agenda in Aboriginal community controlled health services: understanding the relationship between accreditation, continuous quality improvement and national key performance indicator reporting.

    PubMed

    Sibthorpe, Beverly; Gardner, Karen; McAullay, Daniel

    2016-01-01

    A rapidly expanding interest in quality in the Aboriginal-community-controlled health sector has led to widespread uptake of accreditation using more than one set of standards, a proliferation of continuous quality improvement programs and the introduction of key performance indicators. As yet, there has been no overarching logic that shows how they relate to each other, with consequent confusion within and outside the sector. We map the three approaches to the Framework for Performance Assessment in Primary Health Care, demonstrating their key differences and complementarity. There needs to be greater attention in both policy and practice to the purposes and alignment of the three approaches if they are to embed a system-wide focus that supports quality improvement at the service level.

  10. Assessment of breadmaking performance of wheat flour dough by means of frequency dependent ultrasound

    NASA Astrophysics Data System (ADS)

    Braunstein, D.; Page, J. H.; Strybulevych, A.; Peressini, D.; Scanlon, M. G.

    2012-12-01

    Technological performance of wheat flour varies among different wheat varieties. Gluten plays a key role within the solid phase of dough in the formation and the retention of gas bubbles during breadmaking. Rheological tests are usually performed to predict breadmaking potential. The aim here was to investigate the ability of ultrasound to discriminate wheat doughs based on breadmaking qualities. The ultimate goal is the development of an online quality control system currently unavailable in the baked goods industry, rendering this work innovative. Samples were prepared from a strong wheat flour, with one control sample and one added with inulin and distilled monoglycerides, producing doughs of distinct breadmaking quality. Doughs were subjected to density determination, elongation tests, and ultrasound analysis. The ultrasound tests were performed in the frequency range of 300 kHz - 6 MHz. Ultrasonic phase velocity increased with increasing frequency to about 2 MHz, becoming constant and then decreasing from 3 MHz for the control sample. Distinct differences in attenuation coefficient between the fibre-enriched and control doughs were observed. Ultrasound can potentially add to a better understanding of dough quality and can discriminate between doughs of contrasting properties.

  11. Facility versus unit level reporting of quality indicators in nursing homes when performance monitoring is the goal

    PubMed Central

    Norton, Peter G; Murray, Michael; Doupe, Malcolm B; Cummings, Greta G; Poss, Jeff W; Squires, Janet E; Teare, Gary F; Estabrooks, Carole A

    2014-01-01

    Objectives To demonstrate the benefit of defining operational management units in nursing homes and computing quality indicators on these units as well as on the whole facility. Design Calculation of adjusted Resident Assessment Instrument – Minimum Data Set 2.0 (RAI–MDS 2.0) quality indicators for: PRU05 (prevalence of residents with a stage 2–4 pressure ulcer), PAI0X (prevalence of residents with pain) and DRG01 (prevalence of residents receiving an antipsychotic with no diagnosis of psychosis), for quarterly assessments between 2007 and 2011 at unit and facility levels. Comparisons of these risk-adjusted quality indicators using statistical process control (control charts). Setting A representative sample of 30 urban nursing homes in the three Canadian Prairie Provinces. Measurements Explicit decision rules were developed and tested to determine whether the control charts demonstrated improving, worsening, unchanging or unclassifiable trends over the time period. Unit and facility performance were compared. Results In 48.9% of the units studied, unit control chart performance indicated different changes in quality over the reporting period than did the facility chart. Examples are provided to illustrate that these differences lead to quite different quality interventions. Conclusions Our results demonstrate the necessity of considering facility-level and unit-level measurement when calculating quality indicators derived from the RAI–MDS 2.0 data, and quite probably from any RAI measures. PMID:24523428

  12. References on EPA Quality Assurance Project Plans

    EPA Pesticide Factsheets

    Provides requirements for the conduct of quality management practices, including quality assurance (QA) and quality control (QC) activities, for all environmental data collection and environmental technology programs performed by or for this Agency.

  13. Design and implementation of software for automated quality control and data analysis for a complex LC/MS/MS assay for urine opiates and metabolites.

    PubMed

    Dickerson, Jane A; Schmeling, Michael; Hoofnagle, Andrew N; Hoffman, Noah G

    2013-01-16

    Mass spectrometry provides a powerful platform for performing quantitative, multiplexed assays in the clinical laboratory, but at the cost of increased complexity of analysis and quality assurance calculations compared to other methodologies. Here we describe the design and implementation of a software application that performs quality control calculations for a complex, multiplexed, mass spectrometric analysis of opioids and opioid metabolites. The development and implementation of this application improved our data analysis and quality assurance processes in several ways. First, use of the software significantly improved the procedural consistency for performing quality control calculations. Second, it reduced the amount of time technologists spent preparing and reviewing the data, saving on average over four hours per run, and in some cases improving turnaround time by a day. Third, it provides a mechanism for coupling procedural and software changes with the results of each analysis. We describe several key details of the implementation including the use of version control software and automated unit tests. These generally useful software engineering principles should be considered for any software development project in the clinical lab. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Discussion of the quality control and performance testing of ultrasound diagnostic equipment

    NASA Astrophysics Data System (ADS)

    Jiang, Junjie

    2018-03-01

    In recent years, with the rapid development of ultrasonography, the application and popularization of new technology used in ultrasound equipment, the level of providing diagnostic information for doctors enhances unceasingly, which has become the indispensable diagnostic tool for medical institutions. The performance of equipment is directly related to the doctor’s diagnosis and the patient’s health, therefore, it is very important to choose a good method for quality control and performance testing.

  15. 42 CFR 493.1425 - Standard; Testing personnel responsibilities.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... laboratory's quality control policies, document all quality control activities, instrument and procedural... HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS Personnel for Nonwaived Testing Laboratories Performing Moderate Complexity Testing § 493.1425 Standard; Testing personnel...

  16. 10 CFR 63.141 - Scope.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... its structures, systems, or components will perform satisfactorily in service. Quality assurance includes quality control, which comprises those quality assurance actions related to the physical..., NEVADA Quality Assurance § 63.141 Scope. As used in this part, quality assurance comprises all those...

  17. The impact of pay-for-performance on quality of care for minority patients.

    PubMed

    Epstein, Arnold M; Jha, Ashish K; Orav, E John

    2014-10-01

    To determine whether racial disparities in process quality and outcomes of care change under hospital pay-for-performance. Retrospective cohort study comparing the change in racial disparities in process quality and outcomes of care between 2004 and 2008 in hospitals participating in the Premier Hospital Quality Incentive Demonstration versus control hospitals. Using patient-level Hospital Quality Alliance (HQA) data, we identified 226,096 patients in Premier hospitals, which were subject to pay-for-performance (P4P) contracts and 1,607,575 patients at control hospitals who had process of care measured during hospitalization for acute myocardial infarction (AMI), congestive heart failure (CHF), or pneumonia. We additionally identified 123,241 Medicare patients in Premier hospitals and 995,107 in controls who were hospitalized for AMI, CHF, pneumonia, or coronary artery bypass graft (CABG) surgery. We then compared HQA process quality indicators for AMI, CHF, and pneumonia between P4P and control hospitals, as well as risk-adjusted mortality rates for AMI, CHF, pneumonia, and CABG. Black patients initially had lower performance on process quality indicators in both Premier and non-Premier hospitals. The racial gap decreased over time in both groups; the reduction in the gap in Premier hospitals was greater than the gap reduction in non-Premier hospitals for AMI patients. During the study period, mortality generally decreased for blacks relative to whites for AMI, CHF, and pneumonia in both Premier and non-Premier hospitals, with the relative reduction for blacks greatest in Premier hospitals for CHF. Our results show no evidence of a deleterious impact of P4P in the Premier HQID on racial disparities in process quality or outcomes.

  18. A Model of Risk Analysis in Analytical Methodology for Biopharmaceutical Quality Control.

    PubMed

    Andrade, Cleyton Lage; Herrera, Miguel Angel De La O; Lemes, Elezer Monte Blanco

    2018-01-01

    One key quality control parameter for biopharmaceutical products is the analysis of residual cellular DNA. To determine small amounts of DNA (around 100 pg) that may be in a biologically derived drug substance, an analytical method should be sensitive, robust, reliable, and accurate. In principle, three techniques have the ability to measure residual cellular DNA: radioactive dot-blot, a type of hybridization; threshold analysis; and quantitative polymerase chain reaction. Quality risk management is a systematic process for evaluating, controlling, and reporting of risks that may affects method capabilities and supports a scientific and practical approach to decision making. This paper evaluates, by quality risk management, an alternative approach to assessing the performance risks associated with quality control methods used with biopharmaceuticals, using the tool hazard analysis and critical control points. This tool provides the possibility to find the steps in an analytical procedure with higher impact on method performance. By applying these principles to DNA analysis methods, we conclude that the radioactive dot-blot assay has the largest number of critical control points, followed by quantitative polymerase chain reaction, and threshold analysis. From the analysis of hazards (i.e., points of method failure) and the associated method procedure critical control points, we conclude that the analytical methodology with the lowest risk for performance failure for residual cellular DNA testing is quantitative polymerase chain reaction. LAY ABSTRACT: In order to mitigate the risk of adverse events by residual cellular DNA that is not completely cleared from downstream production processes, regulatory agencies have required the industry to guarantee a very low level of DNA in biologically derived pharmaceutical products. The technique historically used was radioactive blot hybridization. However, the technique is a challenging method to implement in a quality control laboratory: It is laborious, time consuming, semi-quantitative, and requires a radioisotope. Along with dot-blot hybridization, two alternatives techniques were evaluated: threshold analysis and quantitative polymerase chain reaction. Quality risk management tools were applied to compare the techniques, taking into account the uncertainties, the possibility of circumstances or future events, and their effects upon method performance. By illustrating the application of these tools with DNA methods, we provide an example of how they can be used to support a scientific and practical approach to decision making and can assess and manage method performance risk using such tools. This paper discusses, considering the principles of quality risk management, an additional approach to the development and selection of analytical quality control methods using the risk analysis tool hazard analysis and critical control points. This tool provides the possibility to find the method procedural steps with higher impact on method reliability (called critical control points). Our model concluded that the radioactive dot-blot assay has the larger number of critical control points, followed by quantitative polymerase chain reaction and threshold analysis. Quantitative polymerase chain reaction is shown to be the better alternative analytical methodology in residual cellular DNA analysis. © PDA, Inc. 2018.

  19. Silent Illumination: A Study on Chan (Zen) Meditation, Anxiety, and Musical Performance Quality

    ERIC Educational Resources Information Center

    Lin, Peter; Chang, Joanne; Zemon, Vance; Midlarsky, Elizabeth

    2008-01-01

    This study investigated the effects of Chan (Zen) meditation on musical performance anxiety and musical performance quality. Nineteen participants were recruited from music conservatories and randomly assigned to either an eight-week meditation group or a wait-list control group. After the intervention, all participants performed in a public…

  20. 77 FR 3228 - Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-23

    ..., Office of Management and Budget (OMB), [email protected] or fax (202) 395-5806 and to... it displays a currently valid OMB control number. Food and Nutrition Service Title: Quality Control... perform Quality Control (QC) review for the Supplemental Nutrition Assistance Program (SNAP). The FNS-380...

  1. [Fitness and quality of life in kidney transplant recipients: case-control study].

    PubMed

    Hernández Sánchez, Sonsoles; Carrero, Juan J; García López, David; Herrero Alonso, Juan Azael; Menéndez Alegre, Héctor; Ruiz, Jonatan R

    2016-04-15

    We analyzed the levels of fitness, muscle structure and quality of life of adults after kidney transplant and healthy adults. A total of 16 kidney transplant patients and 21 healthy controls performed several fitness test, isokinetic evaluation of knee flexion and extension and ultrasonography muscle thickness assessment. They also completed the quality of life questionnaire SF-36. Physical fitness, muscle structure and quality of life of the kidney transplant recipients were significantly poorer than the controls. The transplant patients performed less well in the "get up and go" and "sit to stand" test (p<.001) as well as in assessments of muscle structure, strength and power. The patients had a poorer score in their quality of life assessments, differing from the controls in domains of physical function, physical role, general health and social function (p<.001). Fitness, strength and muscle mass are diminished in kidney transplant patients, resulting in a poorer quality of life which might entail an increased risk to their health. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  2. Quality control tests of lab-reared Cydia pomonella and Cactoblastis cactorum field performance: Comparison of laboratory and field bioassays.

    USDA-ARS?s Scientific Manuscript database

    Research, operational, and commercial programs which rely on mass-reared insects of high quality and performance, need accurate methods for monitoring quality degradation during each step of production, handling and release. With continued interest in the use of the sterile insect technique (SIT) a...

  3. Helicopter roll control effectiveness criteria program summary

    NASA Technical Reports Server (NTRS)

    Heffley, Robert K.; Bourne, Simon M.; Mnich, Marc A.

    1988-01-01

    A study of helicopter roll control effectiveness is summarized for the purpose of defining military helicopter handling qualities requirements. The study is based on an analysis of pilot-in-the-loop task performance of several basic maneuvers. This is extended by a series of piloted simulations using the NASA Ames Vertical Motion Simulator and selected flight data. The main results cover roll control power and short-term response characteristics. In general the handling qualities requirements recommended are set in conjunction with desired levels of flight task and maneuver response which can be directly observed in actual flight. An important aspect of this, however, is that vehicle handling qualities need to be set with regard to some quantitative aspect of mission performance. Specific examples of how this can be accomplished include a lateral unmask/remask maneuver in the presence of a threat and an air tracking maneuver which recognizes the kill probability enhancement connected with decreasing the range to the target. Conclusions and recommendations address not only the handling qualities recommendations, but also the general use of flight simulators and the dependence of mission performance on handling qualities.

  4. [Accesibility and use of spirometry in primary care centers in Catalonia].

    PubMed

    Llauger, M Antònia; Rosas, Alba; Burgos, Felip; Torrente, Elena; Tresserras, Ricard; Escarrabill, Joan

    2014-01-01

    Examine the accessibility and use of forced spirometry (FS) in public primary care facilities centers in Catalonia. Cross-sectional study using a survey. Three hundred sixty-six Primary Care Teams (PCT) in Catalonia. Third quarter of 2010. Survey with information on spirometers, training, interpretation and quality control, and the priority that the quality of spirometry had for the team. Indicators FS/100 inhabitants/year, FS/month/PCT; FS/month/10,000 inhabitants. Response rate: 75%. 97.5% of PCT had spirometer and made an average of 2.01 spirometries/100 inhabitants (34.68 spirometry/PCT/month). 83% have trained professionals.>50% centers perform formal training but no information is available on the quality. 70% performed some sort of calibration. Interpretation was made by the family physician in 87.3% of cases. In 68% of cases not performed any quality control of exploration. 2/3 typed data manually into the computerized medical record.>50% recognized a high priority strategies for improving the quality. Despite the accessibility of EF efforts should be made to standardize training, increasing the number of scans test and promote systematic quality control. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  5. QUALITY CONTROL OF PHARMACEUTICALS.

    PubMed

    LEVI, L; WALKER, G C; PUGSLEY, L I

    1964-10-10

    Quality control is an essential operation of the pharmaceutical industry. Drugs must be marketed as safe and therapeutically active formulations whose performance is consistent and predictable. New and better medicinal agents are being produced at an accelerated rate. At the same time more exacting and sophisticated analytical methods are being developed for their evaluation. Requirements governing the quality control of pharmaceuticals in accordance with the Canadian Food and Drugs Act are cited and discussed.

  6. Implementing Pay-for-Performance in the Neonatal Intensive Care Unit

    PubMed Central

    Profit, Jochen; Zupancic, John A. F.; Gould, Jeffrey B.; Petersen, Laura A.

    2011-01-01

    Pay-for-performance initiatives in medicine are proliferating rapidly. Neonatal intensive care is a likely target for these efforts because of the high cost, available databases, and relative strength of evidence for at least some measures of quality. Pay-for-performance may improve patient care but requires valid measurements of quality to ensure that financial incentives truly support superior performance. Given the existing uncertainty with respect to both the effectiveness of pay-for-performance and the state of quality measurement science, experimentation with pay-for-performance initiatives should proceed with caution and in controlled settings. In this article, we describe approaches to measuring quality and implementing pay-for-performance in the NICU setting. PMID:17473099

  7. The process of managerial control in quality improvement initiatives.

    PubMed

    Slovensky, D J; Fottler, M D

    1994-11-01

    The fundamental intent of strategic management is to position an organization with in its market to exploit organizational competencies and strengths to gain competitive advantage. Competitive advantage may be achieved through such strategies as low cost, high quality, or unique services or products. For health care organizations accredited by the Joint Commission on Accreditation of Healthcare Organizations, continually improving both processes and outcomes of organizational performance--quality improvement--in all operational areas of the organization is a mandated strategy. Defining and measuring quality and controlling the quality improvement strategy remain problematic. The article discusses the nature and processes of managerial control, some potential measures of quality, and related information needs.

  8. Total quality assurance

    NASA Astrophysics Data System (ADS)

    Louzon, E.

    1989-12-01

    Quality, cost, and schedule are three factors affecting the competitiveness of a company; they require balancing so that products of acceptable quality are delivered, on time and at a competitive cost. Quality costs comprise investment in quality maintenance and failure costs which arise from failure to maintain standards. The basic principle for achieving the required quality at minimum cost is that of prevention of failures, etc., through production control, attention to manufacturing practices, and appropriate management and training. Total quality control involves attention to the product throughout its life cycle, including in-service performance evaluation, servicing, and maintenance.

  9. The quest for performance-related specifications for hydraulic cement concrete.

    DOT National Transportation Integrated Search

    1982-01-01

    This paper reviews some of the problems associated with quality assurance for hydraulic cement concrete and the difficulties of relating the results of quality control and acceptance testing to the performance of the concrete facility. The importance...

  10. An early warning and control system for urban, drinking water quality protection: China's experience.

    PubMed

    Hou, Dibo; Song, Xiaoxuan; Zhang, Guangxin; Zhang, Hongjian; Loaiciga, Hugo

    2013-07-01

    An event-driven, urban, drinking water quality early warning and control system (DEWS) is proposed to cope with China's urgent need for protecting its urban drinking water. The DEWS has a web service structure and provides users with water quality monitoring functions, water quality early warning functions, and water quality accident decision-making functions. The DEWS functionality is guided by the principles of control theory and risk assessment as applied to the feedback control of urban water supply systems. The DEWS has been deployed in several large Chinese cities and found to perform well insofar as water quality early warning and emergency decision-making is concerned. This paper describes a DEWS for urban water quality protection that has been developed in China.

  11. Individualized Quality Control Plan (IQCP): Is It Value-Added for Clinical Microbiology?

    PubMed Central

    Miller, Melissa B.; Hindler, Janet

    2015-01-01

    The Center for Medicaid and Medicare Services (CMS) recently published their Individualized Quality Control Plan (IQCP [https://www.cms.gov/regulations-and-guidance/legislation/CLIA/Individualized_Quality_Control_Plan_IQCP.html]), which will be the only option for quality control (QC) starting in January 2016 if laboratories choose not to perform Clinical Laboratory Improvement Act (CLIA) [U.S. Statutes at Large 81(1967):533] default QC. Laboratories will no longer be able to use “equivalent QC” (EQC) or the Clinical and Laboratory Standards Institute (CLSI) standards alone for quality control of their microbiology systems. The implementation of IQCP in clinical microbiology laboratories will most certainly be an added burden, the benefits of which are currently unknown. PMID:26447112

  12. Comparison of laboratory and field bioassays of lab-reared Cydia pomonella (Lepidoptera: Tortricidae) quality and field performance.

    USDA-ARS?s Scientific Manuscript database

    Maximum production and fitness of insect species that are mass-reared for biological control programs such as the sterile insect technique (SIT) have benefitted from the employment of quality control and quality management. With a growing interest in the use of SIT as a tactic for the suppression/e...

  13. Progressing quality control in environmental impact assessment beyond legislative compliance: An evaluation of the IEMA EIA Quality Mark certification scheme

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bond, Alan, E-mail: alan.bond@uea.ac.uk; Research Unit for Environmental Sciences and Management, North-West University; Fischer, Thomas B, E-mail: fischer@liverpool.ac.uk

    The effectiveness of Environmental Impact Assessment (EIA) systems is contingent on a number of control mechanisms: procedural; judicial; evaluative; public and government agency; professional; and development aid agency. If we assume that procedural and judicial controls are guaranteed in developed EIA systems, then progressing effectiveness towards an acceptable level depends on improving the performance of other control mechanisms over time. These other control mechanisms are either absent, or are typically centrally controlled, requiring public finances; this we argue is an unpopular model in times of greater Government austerity. Here we evaluate a market-based mechanism for improving the performance of evaluativemore » and professional control mechanisms, the UK Institute of Environmental Management and Assessments' EIA Quality Mark. We do this by defining dimensions of effectiveness for the purposes of our evaluation, and by identifying international examples of the approaches taken to delivering the other control measures to validate the approach taken in the EIA Quality Mark. We then evaluate the EIA Quality Mark, when used in combination with legal procedures and an active judiciary, against the effectiveness dimensions and use time-series analysis of registrant data to examine its ability to progress practice. We conclude that the EIA Quality Mark has merit as a model for a market-based mechanism, and may prove a more financially palatable approach for delivering effective EIA in mature systems in countries that lack centralised agency oversight. It may, therefore, be of particular interest to some Member States of the European Union for ensuring forthcoming certification requirements stemming from recent amendments to the EIA Directive. - Highlights: • Quality control mechanisms in EIA are identified. • Effectiveness of EIA is conceptualised for evaluation purposes. • The UK IEMA EIA Quality Mark is introduced as a market-based mechanism. • The EIA Quality Mark is found to progress quality in many, but not all, areas.« less

  14. 10 CFR 60.150 - Scope.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... components will perform satisfactorily in service. Quality assurance includes quality control, which... COMMISSION (CONTINUED) DISPOSAL OF HIGH-LEVEL RADIOACTIVE WASTES IN GEOLOGIC REPOSITORIES Quality Assurance § 60.150 Scope. As used in this part, quality assurance comprises all those planned and systematic...

  15. Thermal comfort, perceived air quality, and cognitive performance when personally controlled air movement is used by tropically acclimatized persons.

    PubMed

    Schiavon, S; Yang, B; Donner, Y; Chang, V W-C; Nazaroff, W W

    2017-05-01

    In a warm and humid climate, increasing the temperature set point offers considerable energy benefits with low first costs. Elevated air movement generated by a personally controlled fan can compensate for the negative effects caused by an increased temperature set point. Fifty-six tropically acclimatized persons in common Singaporean office attire (0.7 clo) were exposed for 90 minutes to each of five conditions: 23, 26, and 29°C and in the latter two cases with and without occupant-controlled air movement. Relative humidity was maintained at 60%. We tested thermal comfort, perceived air quality, sick building syndrome symptoms, and cognitive performance. We found that thermal comfort, perceived air quality, and sick building syndrome symptoms are equal or better at 26°C and 29°C than at the common set point of 23°C if a personally controlled fan is available for use. The best cognitive performance (as indicated by task speed) was obtained at 26°C; at 29°C, the availability of an occupant-controlled fan partially mitigated the negative effect of the elevated temperature. The typical Singaporean indoor air temperature set point of 23°C yielded the lowest cognitive performance. An elevated set point in air-conditioned buildings augmented with personally controlled fans might yield benefits for reduced energy use and improved indoor environmental quality in tropical climates. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Quality Control of Pharmaceuticals

    PubMed Central

    Levi, Leo; Walker, George C.; Pugsley, L. I.

    1964-01-01

    Quality control is an essential operation of the pharmaceutical industry. Drugs must be marketed as safe and therapeutically active formulations whose performance is consistent and predictable. New and better medicinal agents are being produced at an accelerated rate. At the same time more exacting and sophisticated analytical methods are being developed for their evaluation. Requirements governing the quality control of pharmaceuticals in accordance with the Canadian Food and Drugs Act are cited and discussed. PMID:14199105

  17. Rotorcraft flying qualities improvement using advanced control

    NASA Technical Reports Server (NTRS)

    Walker, D.; Postlethwaite, I.; Howitt, J.; Foster, N.

    1993-01-01

    We report on recent experience gained when a multivariable helicopter flight control law was tested on the Large Motion Simulator (LMS) at DRA Bedford. This was part of a study into the application of multivariable control theory to the design of full-authority flight control systems for high-performance helicopters. In this paper, we present some of the results that were obtained during the piloted simulation trial and from subsequent off-line simulation and analysis. The performance provided by the control law led to level 1 handling quality ratings for almost all of the mission task elements assessed, both during the real-time and off-line analysis.

  18. HPTLC Fingerprint Analysis: A Quality Control for Authentication of Herbal Phytochemicals

    NASA Astrophysics Data System (ADS)

    Ram, Mauji; Abdin, M. Z.; Khan, M. A.; Jha, Prabhakar

    Authentication and consistent quality are the basic requirement for Indian traditional medicine (TIM), Chinese traditional herbal medicine (TCHM), and their commercial products, regardless of the kind of research conducted to modernize the TIM and TCHM. The complexities of TIM and TCHM challenge the current official quality control mode, for which only a few biochemical markers were selected for identification and quantitative assay. Referring too many unknown factors existed in TIM and TCHM, it is impossible and unnecessary to pinpoint qualitatively and quantitatively every single component contained in the herbal drug. Chromatographic fingerprint is a rational option to meet the need for more effective and powerful quality assessment to TIM and TCHM. The optimized chromatographic fingerprint is not only an alternative analytical tool for authentication, but also an approach to express the various pattern of chemical ingredients distribution in the herbal drugs and preserve such "database" for further multifaced sustainable studies. Analytical separation techniques, for example, high-performance liquid chromatography (HPLC), gas chromatography (GC) and mass spectrometry (MS) were among the most popular methods of choice used for quality control of raw material and finished herbal product. Fingerprint analysis approach using high-performance thin-layer chromatography (HPTLC) has become the most potent tool for quality control of herbal medicines because of its simplicity and reliability. It can serve as a tool for identification, authentication, and quality control of herbal drugs. In this chapter, attempts are being made to expand the use of HPTLC and at the same time create interest among prospective researcher in herbal analysis. The developed method can be used as a quality control tool for rapid authentication from a wide variety of herbal samples. Some examples demonstrated the role of fingerprinting in quality control and assessment.

  19. Incentive spirometry combined with expiratory positive airway pressure improves asthma control and quality of life in asthma: a randomised controlled trial.

    PubMed

    Rondinel, Tatiana Zacarias; Corrêa, Isadora Faraco; Hoscheidt, Luíza Machado; Bueno, Mirelle Hugo; Da Silva, Luciano Muller Corrêa; Reppold, Caroline Tozzi; Dal Lago, Pedro

    2015-03-01

    The use of the incentive spirometer (IS) and expiratory positive airway pressure (EPAP) provides several benefits in patients with respiratory disorders. However, the effects of the use of these devices coupled (IS + EPAP) are still unknown in asthmatic patients. The aim of this study was to evaluate the effect of IS associated with EPAP on exercise tolerance (six-minute walk test - 6MWT), lung function (by spirometry), asthma control (Asthma Control Questionnaire - ACQ) and quality of life (Asthma Quality of Life Questionnaire - AQLQ) in patients with severe asthma. Patients were randomised into two groups: IS + EPAP (n = 8) and control (n = 6). The IS + EPAP group performed breathing exercises at home, twice daily for 20 min, over a period of 5 weeks. There was no significant difference in spirometric variables and in the distance walked in the 6MWT in both groups. However, the IS + EPAP group showed an improvement in asthma control (p = 0.002) and quality of life (p = 0.02). These findings demonstrate that the IS + EPAP protocol, when performed at home, provides an improvement in asthma control and quality of life for patients with severe asthma when evaluated by ACQ and AQLQ, respectively.

  20. Introducing Quality Control in the Chemistry Teaching Laboratory Using Control Charts

    ERIC Educational Resources Information Center

    Schazmann, Benjamin; Regan, Fiona; Ross, Mary; Diamond, Dermot; Paull, Brett

    2009-01-01

    Quality control (QC) measures are less prevalent in teaching laboratories than commercial settings possibly owing to a lack of commercial incentives or teaching resources. This article focuses on the use of QC assessment in the analytical techniques of high performance liquid chromatography (HPLC) and ultraviolet-visible spectroscopy (UV-vis) at…

  1. Modeling Canadian Quality Control Test Program for Steroid Hormone Receptors in Breast Cancer: Diagnostic Accuracy Study.

    PubMed

    Pérez, Teresa; Makrestsov, Nikita; Garatt, John; Torlakovic, Emina; Gilks, C Blake; Mallett, Susan

    The Canadian Immunohistochemistry Quality Control program monitors clinical laboratory performance for estrogen receptor and progesterone receptor tests used in breast cancer treatment management in Canada. Current methods assess sensitivity and specificity at each time point, compared with a reference standard. We investigate alternative performance analysis methods to enhance the quality assessment. We used 3 methods of analysis: meta-analysis of sensitivity and specificity of each laboratory across all time points; sensitivity and specificity at each time point for each laboratory; and fitting models for repeated measurements to examine differences between laboratories adjusted by test and time point. Results show 88 laboratories participated in quality control at up to 13 time points using typically 37 to 54 histology samples. In meta-analysis across all time points no laboratories have sensitivity or specificity below 80%. Current methods, presenting sensitivity and specificity separately for each run, result in wide 95% confidence intervals, typically spanning 15% to 30%. Models of a single diagnostic outcome demonstrated that 82% to 100% of laboratories had no difference to reference standard for estrogen receptor and 75% to 100% for progesterone receptor, with the exception of 1 progesterone receptor run. Laboratories with significant differences to reference standard identified with Generalized Estimating Equation modeling also have reduced performance by meta-analysis across all time points. The Canadian Immunohistochemistry Quality Control program has a good design, and with this modeling approach has sufficient precision to measure performance at each time point and allow laboratories with a significantly lower performance to be targeted for advice.

  2. Performance, Process, and Costs: Managing Service Quality with the Balanced Scorecard.

    ERIC Educational Resources Information Center

    Poll, Roswitha

    2001-01-01

    Describes a cooperative project among three German libraries that used the Balanced Scorecard as a concept for an integrated quality management system. Considers performance indicators across four perspectives that will help academic libraries establish an integrated controlling system and to collect and evaluate performance as well as cost data…

  3. A novel approach to rapidly explore analytical markers for quality control of Radix Salviae Miltiorrhizae extract granules by robust principal component analysis with ultra-high performance liquid chromatography-ultraviolet-quadrupole time-of-flight mass spectrometry.

    PubMed

    Song, Jing-Zheng; Li, Song-Lin; Zhou, Yan; Qiao, Chun-Feng; Chen, Shi-Lin; Xu, Hong-Xi

    2010-11-02

    In a well-controlled experiment, outliers discriminated by robust principal component analysis (RPCA) represent contents in samples which are of particular quality distinguishable from the rest of the others, therefore chemical constituents in a natural product causing discrimination between outliers and the majority of samples could be considered as analytical markers for quality control. Based on this strategy, a novel approach for rapidly exploring characteristic analytical markers was proposed for the quality control of extract granules of Radix Salviae Miltiorrhizae (EGRSM). In this study, large sizes of samples were analyzed via high-throughput ultra-high performance liquid chromatography-ultraviolet-quadrupole time-of-flight mass spectrometry (UHPLC-UV-Q-Tof MS). RPCA was first performed on the three groups of samples: RSM (the raw material), the in-house prepared aqueous extract of Radix Salviae Miltiorrhizae (AERSM) and commercial product of EGRSM, to determine the variation of specific constituents between raw material and the final products as well as the effect of manufacturing process on the overall quality. Then RPCA was performed on the commercial products of EGRSM to explore the applicability of identified characteristic markers for the quality control of EGRSM. Candidate markers were extracted by RPCA, and their molecular formulae were determined by high resolution electrospray ionization-mass spectrometric (ESI-MS) analysis. The suitability of identified markers was then evaluated by determining the relationship between quantities of the identified markers with their antioxidant activities biologically, and further confirmed in a variety of samples. In conclusion, the combination of RPCA with UHPLC-UV-Q-Tof MS is a reliable means to identify chemical markers for evaluating quality of herbal medicines. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  4. Effects of different doses of high-speed resistance training on physical performance and quality of life in older women: a randomized controlled trial

    PubMed Central

    Ramirez-Campillo, Rodrigo; Diaz, Daniela; Martinez-Salazar, Cristian; Valdés-Badilla, Pablo; Delgado-Floody, Pedro; Méndez-Rebolledo, Guillermo; Cañas-Jamet, Rodrigo; Cristi-Montero, Carlos; García-Hermoso, Antonio; Celis-Morales, Carlos; Moran, Jason; Buford, Thomas W; Rodriguez-Mañas, Leocadio; Alonso-Martinez, Alicia M; Izquierdo, Mikel

    2016-01-01

    Objective This study aimed to compare the effects of two frequencies of high-speed resistance training (HSRT) on physical performance and quality of life of older women. Methods A total of 24 older women participated in a 12-week HSRT program composed of either two or three sessions/week (equated for volume and intensity). Women were randomized into three arms: a control group (CG, n=8), a resistance training group performing two sessions/week (RT2, n=8), and a resistance training group performing three sessions/week (RT3, n=8). The training program for both experimental groups included exercises that required high-speed concentric muscle actions. Results No baseline differences were observed among groups. Compared with the CG, both training groups showed similar small to moderate improvements (P<0.05) in muscle strength, power, functional performance, balance, and quality of life. Conclusion These results suggest that equated for volume and intensity, two and three training sessions/week of HSRT are equally effective for improving physical performance and quality of life of older women. PMID:28008239

  5. Effects of different doses of high-speed resistance training on physical performance and quality of life in older women: a randomized controlled trial.

    PubMed

    Ramirez-Campillo, Rodrigo; Diaz, Daniela; Martinez-Salazar, Cristian; Valdés-Badilla, Pablo; Delgado-Floody, Pedro; Méndez-Rebolledo, Guillermo; Cañas-Jamet, Rodrigo; Cristi-Montero, Carlos; García-Hermoso, Antonio; Celis-Morales, Carlos; Moran, Jason; Buford, Thomas W; Rodriguez-Mañas, Leocadio; Alonso-Martinez, Alicia M; Izquierdo, Mikel

    2016-01-01

    This study aimed to compare the effects of two frequencies of high-speed resistance training (HSRT) on physical performance and quality of life of older women. A total of 24 older women participated in a 12-week HSRT program composed of either two or three sessions/week (equated for volume and intensity). Women were randomized into three arms: a control group (CG, n=8), a resistance training group performing two sessions/week (RT2, n=8), and a resistance training group performing three sessions/week (RT3, n=8). The training program for both experimental groups included exercises that required high-speed concentric muscle actions. No baseline differences were observed among groups. Compared with the CG, both training groups showed similar small to moderate improvements ( P <0.05) in muscle strength, power, functional performance, balance, and quality of life. These results suggest that equated for volume and intensity, two and three training sessions/week of HSRT are equally effective for improving physical performance and quality of life of older women.

  6. Performance Measurement and Target-Setting in California's Safety Net Health Systems.

    PubMed

    Hemmat, Shirin; Schillinger, Dean; Lyles, Courtney; Ackerman, Sara; Gourley, Gato; Vittinghoff, Eric; Handley, Margaret; Sarkar, Urmimala

    Health policies encourage implementing quality measurement with performance targets. The 2010-2015 California Medicaid waiver mandated quality measurement and reporting. In 2013, California safety net hospitals participating in the waiver set a voluntary performance target (the 90th percentile for Medicare preferred provider organization plans) for mammography screening and cholesterol control in diabetes. They did not reach the target, and the difference-in-differences analysis suggested that there was no difference for mammography ( P = .39) and low-density lipoprotein control ( P = .11) performance compared to measures for which no statewide quality improvement initiative existed. California's Medicaid waiver was associated with improved performance on a number of metrics, but this performance was not attributable to target setting on specific health conditions. Performance may have improved because of secular trends or systems improvements related to waiver funding. Relying on condition-specific targets to measure performance may underestimate improvements and disadvantage certain health systems. Achieving ambitious targets likely requires sustained fiscal, management, and workforce investments.

  7. 42 CFR 480.135 - Disclosure necessary to perform review responsibilities.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... responsibilities. 480.135 Section 480.135 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF... DISCLOSURE OF QUALITY IMPROVEMENT ORGANIZATION INFORMATION Utilization and Quality Control Quality... stage renal disease services. ...

  8. 42 CFR 480.135 - Disclosure necessary to perform review responsibilities.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... responsibilities. 480.135 Section 480.135 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF... DISCLOSURE OF QUALITY IMPROVEMENT ORGANIZATION INFORMATION Utilization and Quality Control Quality... stage renal disease services. ...

  9. 42 CFR 480.135 - Disclosure necessary to perform review responsibilities.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... responsibilities. 480.135 Section 480.135 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF... DISCLOSURE OF QUALITY IMPROVEMENT ORGANIZATION INFORMATION Utilization and Quality Control Quality... stage renal disease services. ...

  10. 42 CFR 480.135 - Disclosure necessary to perform review responsibilities.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... responsibilities. 480.135 Section 480.135 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF... DISCLOSURE OF QUALITY IMPROVEMENT ORGANIZATION REVIEW INFORMATION Utilization and Quality Control Quality... stage renal disease services. ...

  11. 42 CFR 480.135 - Disclosure necessary to perform review responsibilities.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... responsibilities. 480.135 Section 480.135 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF... DISCLOSURE OF QUALITY IMPROVEMENT ORGANIZATION REVIEW INFORMATION Utilization and Quality Control Quality... stage renal disease services. ...

  12. FIELD QUALITY CONTROL STRATEGIES ASSESSING SOLIDIFICATION/STABILIZATION

    EPA Science Inventory

    Existing regulatory mobility reduction (leaching) tests are not amenable to real time quality control because of the time required to perform sample extraction and chemical analysis. This is of conccern because the leaching test is the most important parameter used to relate trea...

  13. Intelligent Control Approaches for Aircraft Applications

    NASA Technical Reports Server (NTRS)

    Gundy-Burlet, Karen; KrishnaKumar, K.; Soloway, Don; Kaneshige, John; Clancy, Daniel (Technical Monitor)

    2001-01-01

    This paper presents an overview of various intelligent control technologies currently being developed and studied under the Intelligent Flight Control (IFC) program at the NASA Ames Research Center. The main objective of the intelligent flight control program is to develop the next generation of flight controllers for the purpose of automatically compensating for a broad spectrum of damaged or malfunctioning aircraft components and to reduce control law development cost and time. The approaches being examined include: (a) direct adaptive dynamic inverse controller and (b) an adaptive critic-based dynamic inverse controller. These approaches can utilize, but do not require, fault detection and isolation information. Piloted simulation studies are performed to examine if the intelligent flight control techniques adequately: 1) Match flying qualities of modern fly-by-wire flight controllers under nominal conditions; 2) Improve performance under failure conditions when sufficient control authority is available; and 3) Achieve consistent handling qualities across the flight envelope and for different aircraft configurations. Results obtained so far demonstrate the potential for improving handling qualities and significantly increasing survivability rates under various simulated failure conditions.

  14. Developing and implementing a computerized nursing quality control system in a tertiary general medical center in Israel.

    PubMed

    Kagan, Ilya; Cohen, Rachel; Fish, Miri; Mezare, Henia Perry

    2014-01-01

    This article describes the development and implementation of the Nursing Quality Indicators Scale and a quality control system for hospital nursing care, which allows universal access to all external and internal audit results, thus ensuring complete data transparency. Standardized indicators make departments' performance comparable. Key to the new system is nurses' self-audit and responsibility for making quality improvements at the ward level.

  15. Case study for implementing RECIPPE as a quality control in construction projects.

    DOT National Transportation Integrated Search

    2008-04-01

    The quality of construction is a very important factor in the life-cycle performance of flexible pavements. This is particularly true of the individual characteristics of construction and their relative effect on life-cycle performance of the pavemen...

  16. Sigma Metrics Across the Total Testing Process.

    PubMed

    Charuruks, Navapun

    2017-03-01

    Laboratory quality control has been developed for several decades to ensure patients' safety, from a statistical quality control focus on the analytical phase to total laboratory processes. The sigma concept provides a convenient way to quantify the number of errors in extra-analytical and analytical phases through the defect per million and sigma metric equation. Participation in a sigma verification program can be a convenient way to monitor analytical performance continuous quality improvement. Improvement of sigma-scale performance has been shown from our data. New tools and techniques for integration are needed. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Individualized Quality Control Plan (IQCP): Is It Value-Added for Clinical Microbiology?

    PubMed

    Sharp, Susan E; Miller, Melissa B; Hindler, Janet

    2015-12-01

    The Center for Medicaid and Medicare Services (CMS) recently published their Individualized Quality Control Plan (IQCP [https://www.cms.gov/regulations-and-guidance/legislation/CLIA/Individualized_Quality_Control_Plan_IQCP.html]), which will be the only option for quality control (QC) starting in January 2016 if laboratories choose not to perform Clinical Laboratory Improvement Act (CLIA) [U.S. Statutes at Large 81(1967):533] default QC. Laboratories will no longer be able to use "equivalent QC" (EQC) or the Clinical and Laboratory Standards Institute (CLSI) standards alone for quality control of their microbiology systems. The implementation of IQCP in clinical microbiology laboratories will most certainly be an added burden, the benefits of which are currently unknown. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  18. The Status of the Quality Control in Acupuncture-Neuroimaging Studies

    PubMed Central

    Qiu, Ke; Jing, Miaomiao; Liu, Xiaoyan; Gao, Feifei; Liang, Fanrong; Zeng, Fang

    2016-01-01

    Using neuroimaging techniques to explore the central mechanism of acupuncture gains increasing attention, but the quality control of acupuncture-neuroimaging study remains to be improved. We searched the PubMed Database during 1995 to 2014. The original English articles with neuroimaging scan performed on human beings were included. The data involved quality control including the author, sample size, characteristics of the participant, neuroimaging technology, and acupuncture intervention were extracted and analyzed. The rigorous inclusion and exclusion criteria are important guaranty for the participants' homogeneity. The standard operation process of acupuncture and the stricter requirement for acupuncturist play significant role in quality control. More attention should be paid to the quality control in future studies to improve the reproducibility and reliability of the acupuncture-neuroimaging studies. PMID:27242911

  19. Field Performance of High-Quality and Standard Northern Red Oak Seedlings in Tennessee

    Treesearch

    David S. Buckley

    2002-01-01

    First-year performance of high-quality (HQ), high-quality cull (HQC) and standard (ST) northern red oak (Quercus rubra) nursery seedlings was compared in a study established in a recent clearcut in mid-March, 2000. Objectives were to test effects of 1) seedling type, 2) planting treatment, and 3) control of competitors on the growth, browsing, and...

  20. 42 CFR 475.104 - Requirements for demonstrating ability to perform review.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... review. 475.104 Section 475.104 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) QUALITY IMPROVEMENT ORGANIZATIONS QUALITY IMPROVEMENT ORGANIZATIONS Utilization and Quality Control Quality Improvement Organizations § 475.104 Requirements for demonstrating...

  1. Quality, and not just quantity, of education accounts for differences in psychometric performance between african americans and white non-hispanics with Alzheimer's disease.

    PubMed

    Chin, Alexander L; Negash, Selam; Xie, Sharon; Arnold, Steven E; Hamilton, Roy

    2012-03-01

    The effect of race on cognitive test performance in the evaluation of Alzheimer's disease (AD) remains controversial. One factor that may contribute substantially to differences in cognitive test performance in diverse populations is education. The current study examined the extent to which quality of education, even after controlling for formal years of education, accounts for differences in cognitive performance between African Americans and White Non-Hispanics (WNHs). The retrospective cohort included 244 patients diagnosed with AD who self-identified as African Americans (n = 51) or WNHs (n = 193). The Wechsler Test of Adult Reading (WTAR) was used as an estimate of quality of education. In an analysis that controlled for traditional demographics, including age, sex, and years of formal education, African Americans scored significantly lower than WNHs on the Mini-Mental State Examination, as well as on neuropsychological tests of memory, attention, and language. However, after also adjusting for reading level, all previously observed differences were significantly attenuated. The attenuating effect remained even after controlling for disease severity, indicating that reading scores are not confounded by severity of dementia. These findings suggest that quality, and not just quantity, of education needs to be taken into account when assessing cognitive performance in African Americans with AD.

  2. Application of QC_DR software for acceptance testing and routine quality control of direct digital radiography systems: initial experiences using the Italian Association of Physicist in Medicine quality control protocol.

    PubMed

    Nitrosi, Andrea; Bertolini, Marco; Borasi, Giovanni; Botti, Andrea; Barani, Adriana; Rivetti, Stefano; Pierotti, Luisa

    2009-12-01

    Ideally, medical x-ray imaging systems should be designed to deliver maximum image quality at an acceptable radiation risk to the patient. Quality assurance procedures are employed to ensure that these standards are maintained. A quality control protocol for direct digital radiography (DDR) systems is described and discussed. Software to automatically process and analyze the required images was developed. In this paper, the initial results obtained on equipment of different DDR manufacturers were reported. The protocol was developed to highlight even small discrepancies in standard operating performance.

  3. 40 CFR 60.21 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... control equipment or process change; and (5) Final compliance. (i) Region means an air quality control... standard of performance for new stationary sources, but for which air quality criteria have not been issued... account the cost of such reduction) the Administrator has determined has been adequately demonstrated for...

  4. Improve strategic supplier performance using DMAIC to develop a Quality Improvement Plan

    NASA Astrophysics Data System (ADS)

    Jardim, Kevin P.

    Supplier performance that meets the requirements of the customer has long plagued quality professionals. Despite the vast efforts by organizations to improve supplier performance, little has been done to standardize the plan to improve performance. This project presents a guideline and problem-solving strategy using a Define, Measure, Analyze, Improve, and Control (DMAIC) structured tool that will assist in the management and improvement of supplier performance. An analysis of benchmarked Quality Improvement Plans indicated that this topic needs more focus on how to accomplish improved supplier performance. This project is part of a growing body of supplier continuous improvement efforts. With the input of Zodiac Aerospace quality professionals this project's results provide a solution to Quality Improvement Plans and show objective evidence of its benefits. This project contributes to the future research on similar topics.

  5. 42 CFR 493.1445 - Standard; Laboratory director responsibilities.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... quality laboratory services for all aspects of test performance, which includes the preanalytic, analytic... result is found to be unacceptable or unsatisfactory; (5) Ensure that the quality control and quality assessment programs are established and maintained to assure the quality of laboratory services provided and...

  6. Cluster-Randomized Trial of Personalized Site Performance Feedback in Get With The Guidelines-Heart Failure.

    PubMed

    DeVore, Adam D; Cox, Margueritte; Heidenreich, Paul A; Fonarow, Gregg C; Yancy, Clyde W; Eapen, Zubin J; Peterson, Eric D; Hernandez, Adrian F

    2015-07-01

    There is significant variation in the delivery of evidence-based care for patients with heart failure (HF), but there is limited evidence defining the best methods to improve the quality of care. We performed a cluster-randomized trial of personalized site performance feedback at 147 hospitals participating in the Get With The Guidelines-Heart Failure quality improvement program from October 2009 to March 2011. The intervention provided sites with specific data on their heart failure achievement and quality measures in addition to the usual Get With The Guidelines-Heart Failure tools. The primary outcome for our trial was improvement in site composite quality of care score. Overall, 73 hospitals (n=33 886 patients) received the intervention, whereas 74 hospitals (n=37 943 patients) did not. One year after the intervention, both the intervention and control arms had a similar mean change in percentage points in their composite quality score (absolute change, +0.31 [SE, 1.51] versus +3.18 [SE, 1.68] in control; P=0.21). Similarly, none of the individual achievement measures or quality measures improved more at intervention versus control hospitals. Our site-based intervention, which included personalized site feedback on adherence to quality metrics, was not able to elicit more quality improvement beyond that already associated with participation in the Get With The Guidelines-Heart Failure program. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00979264. © 2015 American Heart Association, Inc.

  7. High-Performance Integrated Control of water quality and quantity in urban water reservoirs

    NASA Astrophysics Data System (ADS)

    Galelli, S.; Castelletti, A.; Goedbloed, A.

    2015-11-01

    This paper contributes a novel High-Performance Integrated Control framework to support the real-time operation of urban water supply storages affected by water quality problems. We use a 3-D, high-fidelity simulation model to predict the main water quality dynamics and inform a real-time controller based on Model Predictive Control. The integration of the simulation model into the control scheme is performed by a model reduction process that identifies a low-order, dynamic emulator running 4 orders of magnitude faster. The model reduction, which relies on a semiautomatic procedural approach integrating time series clustering and variable selection algorithms, generates a compact and physically meaningful emulator that can be coupled with the controller. The framework is used to design the hourly operation of Marina Reservoir, a 3.2 Mm3 storm-water-fed reservoir located in the center of Singapore, operated for drinking water supply and flood control. Because of its recent formation from a former estuary, the reservoir suffers from high salinity levels, whose behavior is modeled with Delft3D-FLOW. Results show that our control framework reduces the minimum salinity levels by nearly 40% and cuts the average annual deficit of drinking water supply by about 2 times the active storage of the reservoir (about 4% of the total annual demand).

  8. Survey of point-of-care instrumentation, analysis, and quality assurance in veterinary practice.

    PubMed

    Bell, Regan; Harr, Kendal; Rishniw, Mark; Pion, Paul

    2014-06-01

    While there have been ASVCP meeting discussions regarding quality assurance plans and lack thereof for in-clinic analyzers, there are little published data regarding in-clinic quality assurance and control practices. The purpose of this study was the identification of the common equipment used in hematologic, biochemical, urinalysis, and other testing, and assessment of quality control and assurance programs currently being performed in-clinic. All members of the Veterinary Information Network (VIN) were solicited to participate in an online survey between July and September 2007. In total, 452 complete or partial responses were received. Eighty-nine percent of respondents (361/404) said that veterinary technicians (unlicensed, licensed, and registered) performed the majority of analyses. Eighty-eight percent (366/417) of respondents performed some quality assurance on their laboratory equipment, most commonly on chemistry (91%, 324/357), and hematology (84%, 292/347) analyzers, and least commonly on fecal analyses (57%, 148/260) and ELISA assays (25%, 65/256). Ignorance of how to perform quality assurance was the most commonly stated reason (49%, 25/51) for lack of a quality assurance program. The majority of practices (316/374) utilized manufacturer-provided reference intervals without further adjustment or assessment. Roughly one-third of respondents (126/374) used reference intervals from textbooks, which is discouraged by ASVCP guidelines. This study found that the majority of respondents were not in compliance with ASVCP guidelines, illustrating the need for improved education of technical staff, veterinary students, and veterinarians regarding limitations of in-clinic laboratory equipment and the importance of regular quality control, maintenance, training, and reference interval development. © 2014 American Society for Veterinary Clinical Pathology and European Society for Veterinary Clinical Pathology.

  9. ECG compression using non-recursive wavelet transform with quality control

    NASA Astrophysics Data System (ADS)

    Liu, Je-Hung; Hung, King-Chu; Wu, Tsung-Ching

    2016-09-01

    While wavelet-based electrocardiogram (ECG) data compression using scalar quantisation (SQ) yields excellent compression performance, a wavelet's SQ scheme, however, must select a set of multilevel quantisers for each quantisation process. As a result of the properties of multiple-to-one mapping, however, this scheme is not conducive for reconstruction error control. In order to address this problem, this paper presents a single-variable control SQ scheme able to guarantee the reconstruction quality of wavelet-based ECG data compression. Based on the reversible round-off non-recursive discrete periodised wavelet transform (RRO-NRDPWT), the SQ scheme is derived with a three-stage design process that first uses genetic algorithm (GA) for high compression ratio (CR), followed by a quadratic curve fitting for linear distortion control, and the third uses a fuzzy decision-making for minimising data dependency effect and selecting the optimal SQ. The two databases, Physikalisch-Technische Bundesanstalt (PTB) and Massachusetts Institute of Technology (MIT) arrhythmia, are used to evaluate quality control performance. Experimental results show that the design method guarantees a high compression performance SQ scheme with statistically linear distortion. This property can be independent of training data and can facilitate rapid error control.

  10. Improvements in cognition, quality of life, and physical performance with clinical Pilates in multiple sclerosis: a randomized controlled trial

    PubMed Central

    Küçük, Fadime; Kara, Bilge; Poyraz, Esra Çoşkuner; İdiman, Egemen

    2016-01-01

    [Purpose] The aim of this study was to determine the effects of clinical Pilates in multiple sclerosis patients. [Subjects and Methods] Twenty multiple sclerosis patients were enrolled in this study. The participants were divided into two groups as the clinical Pilates and control groups. Cognition (Multiple Sclerosis Functional Composite), balance (Berg Balance Scale), physical performance (timed performance tests, Timed up and go test), tiredness (Modified Fatigue Impact scale), depression (Beck Depression Inventory), and quality of life (Multiple Sclerosis International Quality of Life Questionnaire) were measured before and after treatment in all participants. [Results] There were statistically significant differences in balance, timed performance, tiredness and Multiple Sclerosis Functional Composite tests between before and after treatment in the clinical Pilates group. We also found significant differences in timed performance tests, the Timed up and go test and the Multiple Sclerosis Functional Composite between before and after treatment in the control group. According to the difference analyses, there were significant differences in Multiple Sclerosis Functional Composite and Multiple Sclerosis International Quality of Life Questionnaire scores between the two groups in favor of the clinical Pilates group. There were statistically significant clinical differences in favor of the clinical Pilates group in comparison of measurements between the groups. Clinical Pilates improved cognitive functions and quality of life compared with traditional exercise. [Conclusion] In Multiple Sclerosis treatment, clinical Pilates should be used as a holistic approach by physical therapists. PMID:27134355

  11. Improvements in cognition, quality of life, and physical performance with clinical Pilates in multiple sclerosis: a randomized controlled trial.

    PubMed

    Küçük, Fadime; Kara, Bilge; Poyraz, Esra Çoşkuner; İdiman, Egemen

    2016-03-01

    [Purpose] The aim of this study was to determine the effects of clinical Pilates in multiple sclerosis patients. [Subjects and Methods] Twenty multiple sclerosis patients were enrolled in this study. The participants were divided into two groups as the clinical Pilates and control groups. Cognition (Multiple Sclerosis Functional Composite), balance (Berg Balance Scale), physical performance (timed performance tests, Timed up and go test), tiredness (Modified Fatigue Impact scale), depression (Beck Depression Inventory), and quality of life (Multiple Sclerosis International Quality of Life Questionnaire) were measured before and after treatment in all participants. [Results] There were statistically significant differences in balance, timed performance, tiredness and Multiple Sclerosis Functional Composite tests between before and after treatment in the clinical Pilates group. We also found significant differences in timed performance tests, the Timed up and go test and the Multiple Sclerosis Functional Composite between before and after treatment in the control group. According to the difference analyses, there were significant differences in Multiple Sclerosis Functional Composite and Multiple Sclerosis International Quality of Life Questionnaire scores between the two groups in favor of the clinical Pilates group. There were statistically significant clinical differences in favor of the clinical Pilates group in comparison of measurements between the groups. Clinical Pilates improved cognitive functions and quality of life compared with traditional exercise. [Conclusion] In Multiple Sclerosis treatment, clinical Pilates should be used as a holistic approach by physical therapists.

  12. A Methodology for Performing Effects-Based Assessments

    DTIC Science & Technology

    2006-03-01

    can then be used to make assessments (Smith, 2002:384). 2.8 Cause-and-Effect Diagrams Developed by Dr. Kaoru Ishikawa in the field of Quality Control...John Wiley & Sons, Inc., 2004. Ishikawa , Kaoru . Guide to Quality Control. White Plains NY: Asian Productivity Organization, 1989...various causes affecting product quality by sorting out and relating the causes. Cause-and-effect diagrams are sometimes called Ishikawa diagrams, or

  13. Evaluation of feedback interventions for improving the quality assurance of cancer screening in Japan: study design and report of the baseline survey.

    PubMed

    Machii, Ryoko; Saika, Kumiko; Higashi, Takahiro; Aoki, Ayako; Hamashima, Chisato; Saito, Hiroshi

    2012-02-01

    The importance of quality assurance in cancer screening has recently gained increasing attention in Japan. To evaluate and improve quality, checklists and process indicators have been developed. To explore effective methods of enhancing quality in cancer screening, we started a randomized control study of the methods of evaluation and feedback for cancer control from 2009 to 2014. We randomly assigned 1270 municipal governments, equivalent to 71% of all Japanese municipal governments that performed screening programs, into three groups. The high-intensity intervention groups (n = 425) were individually evaluated using both checklist performance and process indicator values, while the low-intensity intervention groups (n= 421) were individually evaluated on the basis of only checklist performance. The control group (n = 424) received only a basic report that included the national average of checklist performance scores. We repeated the survey for each municipality's quality assurance activity performance using checklists and process indicators. In this paper, we report our study design and the result of the baseline survey. The checklist adherence rates were especially low in the checklist elements related to invitation of individuals, detailed monitoring of process indicators such as cancer detection rates according to screening histories and appropriate selection of screening facilities. Screening rate and percentage of examinees who underwent detailed examination tended to be lower for large cities when compared with smaller cities for all cancer sites. The performance of the Japanese cancer screening program in 2009 was identified for the first time.

  14. Analytic Methods Used in Quality Control in a Compounding Pharmacy.

    PubMed

    Allen, Loyd V

    2017-01-01

    Analytical testing will no doubt become a more important part of pharmaceutical compounding as the public and regulatory agencies demand increasing documentation of the quality of compounded preparations. Compounding pharmacists must decide what types of testing and what amount of testing to include in their quality-control programs, and whether testing should be done in-house or outsourced. Like pharmaceutical compounding, analytical testing should be performed only by those who are appropriately trained and qualified. This article discusses the analytical methods that are used in quality control in a compounding pharmacy. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  15. Screening bioactive quality control markers of QiShenYiQi dripping pills based on the relationship between the ultra-high performance liquid chromatography fingerprint and vascular protective activity.

    PubMed

    Zhuo, Limeng; Peng, Jingjing; Zhao, Yunli; Li, Dongxiang; Xie, Xiuman; Tong, Ling; Yu, Zhiguo

    2017-10-01

    Traditional Chinese medicine consists of complex phytochemical constituents. Selecting appropriate analytical markers of traditional Chinese medicine is a critical step in quality control. Currently, the combination of fingerprinting and efficacy evaluation is considered as a useful method for screening active ingredients in complex mixtures. This study was designed to develop an orthogonal partial least squares model for screening bioactive quality control markers of QishenYiqi dripping pills based on the fingerprint-efficacy relationship. First, the chemical fingerprints of 49 batches of QishenYiqi dripping pill samples were established by ultra-high performance liquid chromatography coupled with a photodiode array detector. Second, ultra-high performance liquid chromatography coupled with quadrupole-time-of-flight mass spectrometry was exploited to systematically investigate the 36 copossessing fingerprint components in QishenYiqi dripping pills. The vascular protective activity of QishenYiqi dripping pills was determined by using a cell counting kit-8 assay. Finally, fingerprint-efficacy relationship was established by orthogonal partial least squares model. The results indicated that ten components exhibited strong correlation with vascular protective activity, and these were preliminarily screened as quality control markers. The present study provided a novel idea for the study of the pharmacodynamic material basis and quality evaluation of QishenYiqi dripping pills. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. High-performance thin layer chromatography to assess pharmaceutical product quality.

    PubMed

    Kaale, Eliangiringa; Manyanga, Vicky; Makori, Narsis; Jenkins, David; Michael Hope, Samuel; Layloff, Thomas

    2014-06-01

    To assess the sustainability, robustness and economic advantages of high-performance thin layer chromatography (HPTLC) for quality control of pharmaceutical products. We compared three laboratories where three lots of cotrimoxazole tablets were assessed using different techniques for quantifying the active ingredient. The average assay relative standard deviation for the three lots was 1.2 with a range of 0.65-2.0. High-performance thin layer chromatography assessments are yielding valid results suitable for assessing product quality. The local pharmaceutical manufacturer had evolved the capacity to produce very high quality products. © 2014 John Wiley & Sons Ltd.

  17. Analysis And Control System For Automated Welding

    NASA Technical Reports Server (NTRS)

    Powell, Bradley W.; Burroughs, Ivan A.; Kennedy, Larry Z.; Rodgers, Michael H.; Goode, K. Wayne

    1994-01-01

    Automated variable-polarity plasma arc (VPPA) welding apparatus operates under electronic supervision by welding analysis and control system. System performs all major monitoring and controlling functions. It acquires, analyzes, and displays weld-quality data in real time and adjusts process parameters accordingly. Also records pertinent data for use in post-weld analysis and documentation of quality. System includes optoelectronic sensors and data processors that provide feedback control of welding process.

  18. Control of maglev vehicles with aerodynamic and guideway disturbances

    NASA Technical Reports Server (NTRS)

    Flueckiger, Karl; Mark, Steve; Caswell, Ruth; Mccallum, Duncan

    1994-01-01

    A modeling, analysis, and control design methodology is presented for maglev vehicle ride quality performance improvement as measured by the Pepler Index. Ride quality enhancement is considered through active control of secondary suspension elements and active aerodynamic surfaces mounted on the train. To analyze and quantify the benefits of active control, the authors have developed a five degree-of-freedom lumped parameter model suitable for describing a large class of maglev vehicles, including both channel and box-beam guideway configurations. Elements of this modeling capability have been recently employed in studies sponsored by the U.S. Department of Transportation (DOT). A perturbation analysis about an operating point, defined by vehicle and average crosswind velocities, yields a suitable linearized state space model for multivariable control system analysis and synthesis. Neglecting passenger compartment noise, the ride quality as quantified by the Pepler Index is readily computed from the system states. A statistical analysis is performed by modeling the crosswind disturbances and guideway variations as filtered white noise, whereby the Pepler Index is established in closed form through the solution to a matrix Lyapunov equation. Data is presented which indicates the anticipated ride quality achieved through various closed-loop control arrangements.

  19. Assessment of non-destructive testing technologies for quality control/quality assurance of asphalt mixtures : [tech transfer summary].

    DOT National Transportation Integrated Search

    2015-02-01

    Evaluation of the actual performance (quality) of pavements requires : in situ nondestructive testing (NDT) techniques that can accurately : measure the most critical, objective, and sensitive properties of : pavement systems.

  20. Evaluation of MIT-SCAN-T2 for Thickness Quality Control for PCC and HMA Pavements

    DOT National Transportation Integrated Search

    2018-02-01

    Thickness is currently a pay item for PCC pavements and a quality control item for both PCC and HMA pavements. A change in pavement thickness of 0.5 in. can result in a change of multiple years of service. Current thickness measurements are performed...

  1. Quality control ranges for testing broth microdilution susceptibility of Flavobacterium columnare and F. psychrophilium to nine antimicrobials

    USDA-ARS?s Scientific Manuscript database

    A multi-laboratory broth microdilution method trial was performed to standardize the specialized test conditions required for fish pathogens Flavobacterium columnare and F. pyschrophilum. Nine laboratories tested the quality control (QC) strains Escherichia coli ATCC 25922 and Aeromonas salmonicid...

  2. Adaptive prospective ECG-triggered sequence coronary angiography in dual-source CT without heart rate control: Image quality and diagnostic performance.

    PubMed

    Pan, Chang-Jie; Qian, Nong; Wang, Tao; Tang, Xiao-Qiang; Xue, Yue-Jun

    2013-02-01

    The aim of this study was to evaluate the accuracy of using second generation dual-source CT (DSCT) to obtain high quality images and diagnostic performance and to reduce the radiation dose in adaptive prospective electrocardiography (ECG)-triggered sequence (CorAdSeq) CT coronary angiography (CTCA) without heart rate control. No prescan β-blockers were administered. Un-enhanced CT and CTCA with adaptive prospective CorAdSeq scanning without heart rate control were performed in 683 consecutive patients divided into two body mass index (BMI) groups: BMI <25 kg/m(2) (group A, n=412) and BMI ≥25 kg/m(2) (group B, n=271). The image quality and quantitative stenosis of all coronary segments with a diameter ≥1 mm were assessed. The mean heart rate (MHR), heart rate variability (HRV) and radiation dose values were recorded. In 426 cases, the diagnostic performance was evaluated using quantitative conventional coronary angiography as the reference standard. Diagnostic image quality was obtained in 98.5% of segments in group A and in 98.8% of segments in group B, with no significant differences between the groups. No correlations were observed between the image quality score and MHR or HRV (P=0.492, P=0.564, respectively). The effective radiation doses in groups A and B were 2.57±1.01 mSv and 6.36±1.88 mSv, respectively. The sensitivities and specificities of diagnosing coronary heart disease per patient were 99.6% and 97.8% in group A and 99.5% and 97.5% in group B, respectively (P>0.05). Adaptive prospective CorAdSeq scanning, without heart rate control, by second generation DSCT had a high image quality and diagnostic performance for coronary artery stenosis with lower radiation doses.

  3. National Survey on Internal Quality Control for HbA(1c) Analytical Instruments in 331 Hospital Laboratories of China.

    PubMed

    Zeng, Rong; Wang, Wei; Zhao, Haijian; Fei, Yang; Wang, Zhiguo

    2015-01-01

    The narrow gap of HbA1 value of mass fraction between "normal" (< 6.0%) and "diabetes" (≥ 6.5%) necessitates tight control of inter-assay standardization, assay precision, and trueness. This survey was initiated to obtain knowledge of the current situation of internal quality control (IQC) practice for HbA(1c) in China and find out the most appropriate quality specifications. Data of IQC for HbA(1c) in 331 institutions participating in the national proficiency testing (PT) programs in China were evaluated using four levels of quality specifications, and the percentages of laboratories meeting the quality requirement were calculated to find out the most appropriate quality specifications for control materials of HbA(1c) in China. The IQC data varied vastly among 331 clinical laboratories in China. The measurement of control materials covered a wide range from 4.52% to 12.24% (inter-quartile range) and there were significant differences among the CVs of different methods, including LPLC, CE-HPLC, AC-HPLC, immunoturbidimetry, and others. Among the four main methods, CE-HPLC and AC-HPLC achieved a better precision. As we can see, the performance of laboratories for HbA(1c) has yet to be improved. Clinical laboratories in China should improve their performance with a stricter imprecision criteria.

  4. Multileaf collimator performance monitoring and improvement using semiautomated quality control testing and statistical process control.

    PubMed

    Létourneau, Daniel; Wang, An; Amin, Md Nurul; Pearce, Jim; McNiven, Andrea; Keller, Harald; Norrlinger, Bernhard; Jaffray, David A

    2014-12-01

    High-quality radiation therapy using highly conformal dose distributions and image-guided techniques requires optimum machine delivery performance. In this work, a monitoring system for multileaf collimator (MLC) performance, integrating semiautomated MLC quality control (QC) tests and statistical process control tools, was developed. The MLC performance monitoring system was used for almost a year on two commercially available MLC models. Control charts were used to establish MLC performance and assess test frequency required to achieve a given level of performance. MLC-related interlocks and servicing events were recorded during the monitoring period and were investigated as indicators of MLC performance variations. The QC test developed as part of the MLC performance monitoring system uses 2D megavoltage images (acquired using an electronic portal imaging device) of 23 fields to determine the location of the leaves with respect to the radiation isocenter. The precision of the MLC performance monitoring QC test and the MLC itself was assessed by detecting the MLC leaf positions on 127 megavoltage images of a static field. After initial calibration, the MLC performance monitoring QC test was performed 3-4 times/week over a period of 10-11 months to monitor positional accuracy of individual leaves for two different MLC models. Analysis of test results was performed using individuals control charts per leaf with control limits computed based on the measurements as well as two sets of specifications of ± 0.5 and ± 1 mm. Out-of-specification and out-of-control leaves were automatically flagged by the monitoring system and reviewed monthly by physicists. MLC-related interlocks reported by the linear accelerator and servicing events were recorded to help identify potential causes of nonrandom MLC leaf positioning variations. The precision of the MLC performance monitoring QC test and the MLC itself was within ± 0.22 mm for most MLC leaves and the majority of the apparent leaf motion was attributed to beam spot displacements between irradiations. The MLC QC test was performed 193 and 162 times over the monitoring period for the studied units and recalibration had to be repeated up to three times on one of these units. For both units, rate of MLC interlocks was moderately associated with MLC servicing events. The strongest association with the MLC performance was observed between the MLC servicing events and the total number of out-of-control leaves. The average elapsed time for which the number of out-of-specification or out-of-control leaves was within a given performance threshold was computed and used to assess adequacy of MLC test frequency. A MLC performance monitoring system has been developed and implemented to acquire high-quality QC data at high frequency. This is enabled by the relatively short acquisition time for the images and automatic image analysis. The monitoring system was also used to record and track the rate of MLC-related interlocks and servicing events. MLC performances for two commercially available MLC models have been assessed and the results support monthly test frequency for widely accepted ± 1 mm specifications. Higher QC test frequency is however required to maintain tighter specification and in-control behavior.

  5. VERIFYING THE VOC CONTROL PERFORMANCE OF BIOREACTORS

    EPA Science Inventory

    The paper describes the verification testing approach used to collect high-quality, peer-reviewed data on the performance of bioreaction-based technologies for the control of volatile organic compounds (VOCs). The verification protocol that describes the approach for these tests ...

  6. Guidelines for the detection of Trichinella larvae at the slaughterhouse in a quality assurance system.

    PubMed

    Rossi, Patrizia; Pozio, Edoardo

    2008-01-01

    The European Community Regulation (EC) No. 2075/2005 lays down specific rules on official controls for the detection of Trichinella in fresh meat for human consumption, recommending the pooled-sample digestion method as the reference method. The aim of this document is to provide specific guidance to implement an appropriate Trichinella digestion method by a laboratory accredited according to the ISO/IEC 17025:2005 international standard, and performing microbiological testing following the EA-04/10:2002 international guideline. Technical requirements for the correct implementation of the method, such as the personnel competence, specific equipments and reagents, validation of the method, reference materials, sampling, quality assurance of results and quality control of performance are provided, pointing out the critical control points for the correct implementation of the digestion method.

  7. The Quality Movements in Higher Education in the United States.

    ERIC Educational Resources Information Center

    Miller, Richard I.

    1996-01-01

    Discussion of various quality control strategies in American higher education looks at and compares Total Quality Management (TQM), outcomes assessment, Deming's 14 points, the Malcolm Baldrige National Quality Award, the ISO 9000 series, restructuring, reengineering, and performance indicators. It is suggested that colleges and universities will…

  8. 42 CFR 493.1407 - Standard; Laboratory director responsibilities.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... developed and used for each of the tests performed in the laboratory provide quality laboratory services for... results are found to be unacceptable or unsatisfactory; (5) Ensure that the quality control and quality assessment programs are established and maintained to assure the quality of laboratory services provided and...

  9. Cochlear Implantation in Patients With Usher Syndrome Type IIa Increases Performance and Quality of Life.

    PubMed

    Hartel, Bas P; van Nierop, Josephine W I; Huinck, Wendy J; Rotteveel, Liselotte J C; Mylanus, Emmanuel A M; Snik, Ad F; Kunst, Henricus P M; Pennings, Ronald J E

    2017-07-01

    Usher syndrome type IIa (USH2a) is characterized by congenital moderate to severe hearing impairment and retinitis pigmentosa. Hearing rehabilitation starts in early childhood with the application of hearing aids. In some patients with USH2a, severe progression of hearing impairment leads to insufficient speech intelligibility with hearing aids and issues with adequate communication and safety. Cochlear implantation (CI) is the next step in rehabilitation of such patients. This study evaluates the performance and benefit of CI in patients with USH2a. Retrospective case-control study to evaluate the performance and benefit of CI in 16 postlingually deaf adults (eight patients with USH2a and eight matched controls). Performance and benefit were evaluated by a speech intelligibility test and three quality-of-life questionnaires. Patients with USH2a with a mean age of 59 years at implantation exhibited good performance after CI. The phoneme scores improved significantly from 41 to 87% in patients with USH2a (p = 0.02) and from 30 to 86% in the control group (p = 0.001). The results of the questionnaire survey demonstrated a clear benefit from CI. There were no differences in performance or benefit between patients with USH2a and control patients before and after CI. CI increases speech intelligibility and improves quality of life in patients with USH2a.

  10. Organizational Leadership and Adaptive Reserve in Blood Pressure Control: The Heart Health NOW Study.

    PubMed

    Henderson, Kamal H; DeWalt, Darren A; Halladay, Jacquie; Weiner, Bryan J; Kim, Jung I; Fine, Jason; Cykert, Samuel

    2018-04-01

    Our purpose was to assess whether a practice's adaptive reserve and high leadership capability in quality improvement are associated with population blood pressure control. We divided practices into quartiles of blood pressure control performance and considered the top quartile as the benchmark for comparison. Using abstracted clinical data from electronic health records, we performed a cross-sectional study to assess the association of top quartile hypertension control and (1) the baseline practice adaptive reserve (PAR) scores and (2) baseline practice leadership scores, using modified Poisson regression models adjusting for practice-level characteristics. Among 181 practices, 46 were in the top quartile, which averaged 68% or better blood pressure control. Practices with higher PAR scores compared with lower PAR scores were not more likely to reside in the top quartile of performance (prevalence ratio [PR] = 1.92 for highest quartile; 95% CI, 0.9-4.1). Similarly, high quality improvement leadership capability compared with lower capability did not predict better blood pressure control performance (PR = 0.94; 95% CI, 0.57-1.56). Practices with higher proportions of commercially insured patients were more likely than practices with lower proportions of commercially insured patients to have top quartile performance (37% vs 26%, P =.002), whereas lower proportions of the uninsured (8% vs 14%, P =.055) were associated with better performance. Our findings show that adaptive reserve and leadership capability in quality improvement implementation are not statistically associated with achieving top quartile practice-level hypertension control at baseline in the Heart Health NOW project. Our findings, however, may be limited by a lack of patient-related factors and small sample size to preclude strong conclusions. © 2018 Annals of Family Medicine, Inc.

  11. Integrated Application of Quality-by-Design Principles to Drug Product Development: A Case Study of Brivanib Alaninate Film-Coated Tablets.

    PubMed

    Badawy, Sherif I F; Narang, Ajit S; LaMarche, Keirnan R; Subramanian, Ganeshkumar A; Varia, Sailesh A; Lin, Judy; Stevens, Tim; Shah, Pankaj A

    2016-01-01

    Modern drug product development is expected to follow quality-by-design (QbD) paradigm. At the same time, although there are several issue-specific examples in the literature that demonstrate the application of QbD principles, a holistic demonstration of the application of QbD principles to drug product development and control strategy, is lacking. This article provides an integrated case study on the systematic application of QbD to product development and demonstrates the implementation of QbD concepts in the different aspects of product and process design for brivanib alaninate film-coated tablets. Using a risk-based approach, the strategy for development entailed identification of product critical quality attributes (CQAs), assessment of risks to the CQAs, and performing experiments to understand and mitigate identified risks. Quality risk assessments and design of experiments were performed to understand the quality of the input raw materials required for a robust formulation and the impact of manufacturing process parameters on CQAs. In addition to the material property and process parameter controls, the proposed control strategy includes use of process analytical technology and conventional analytical tests to control in-process material attributes and ensure quality of the final product. Copyright © 2016. Published by Elsevier Inc.

  12. Residual risk of bacterial contamination of platelets: six years of experience with sterility testing.

    PubMed

    Ramirez-Arcos, Sandra; DiFranco, Caesar; McIntyre, Terri; Goldman, Mindy

    2017-09-01

    Canadian Blood Services screens 100% of platelet concentrates (PCs) for bacterial contamination with the BacT/ALERT system. Quality-control sterility testing of 1% (≥10 units) of outdated PCs is performed monthly. Data from routine screening, quality-control testing, and septic reactions obtained from 2010 to 2016 are presented herein. In total, 601,988 buffy coat PC pools and 186,737 apheresis PCs were routinely screened with aerobic cultures over 6 years. Outdate quality-control testing of 8535 buffy coat and 8498 apheresis PCs was performed using aerobic and anaerobic cultures during the same period. Results were classified as "true-positives" when the same bacterium was isolated in initial and confirmatory cultures or "false-negatives" when bacteria were missed in early screening and were captured during quality-control sterility testing or through investigation of sepsis cases. During routine screening, the true-positive rates between buffy coat (0.94 per 10,000) and apheresis (0.96 per 10,000) PCs were similar (p = 0.9473). Seventy-five bacteria isolated during PC screening included Gram-positive and Gram-negative organisms. Six false-negative septic reactions were reported that implicated coagulase-negative staphylococci (n = 3) and Staphylococcus aureus (n = 3) for approximate rates of 1 per 100,000 transfusion reactions and 1 per 500,000 fatalities. During quality-control testing, the false-negative rates between buffy coat (8 per 10,000) and apheresis (9 per 10,000) PCs were similar (p = 0.7897). All 15 quality-control isolates were Gram-positive bacteria. The current bacterial screening protocol is efficacious for identifying Gram-negative bacteria. However, the high proportion of Gram-positive organisms detected on outdate quality-control testing and septic transfusion events demonstrates a residual safety risk that merits further intervention. © 2017 AABB.

  13. [Quality of health care for diabetic and hypertensive patients in primary care settings servicing Mexican Seguro Popular].

    PubMed

    Ortiz-Domínguez, Maki E; Garrido-Latorre, Francisco; Orozco, Ricardo; Pineda-Pérez, Dayana; Rodríguez-Salgado, Marlenne

    2011-01-01

    To assess health care quality provided to type-2 diabetic and hypertensive patients in primary care settings from the Mexican Ministry of Health and to evaluate whether accredited clinics providing services to the Mexican Seguro Popular performed better in terms of metabolic control of those patients compared to the non-accredited. Cross-sectional study performed on 2008. Previous year clinical measures were obtained from 5 444 diabetic and 5 827 hypertensive patient's clinical records. Adequate metabolic control (glucose <110 mg/dl for diabetes and blood pressure <140/90 mmHg for hypertension) associated factors were assessed by multiple-multilevel logistic regression methods. Patients attending accredited clinics were more likely to be controlled, however, metabolic control was not constant over time of accreditation. Additional efforts are required to monitor accredited clinics' performance in order to maintain both metabolic control and clinical assessment of patients.

  14. Pulse-Flow Microencapsulation System

    NASA Technical Reports Server (NTRS)

    Morrison, Dennis R.

    2006-01-01

    The pulse-flow microencapsulation system (PFMS) is an automated system that continuously produces a stream of liquid-filled microcapsules for delivery of therapeutic agents to target tissues. Prior microencapsulation systems have relied on batch processes that involve transfer of batches between different apparatuses for different stages of production followed by sampling for acquisition of quality-control data, including measurements of size. In contrast, the PFMS is a single, microprocessor-controlled system that performs all processing steps, including acquisition of quality-control data. The quality-control data can be used as real-time feedback to ensure the production of large quantities of uniform microcapsules.

  15. Restless Leg Syndrome and Sleep Quality in Lumbar Radiculopathy Patients

    PubMed Central

    Terzi, Murat; Akpinar, Kursad; Paksoy, Kemal; Cebeci, Ibrahim; Iyigun, Omer

    2014-01-01

    Background. To investigate the frequency of restless leg syndrome (RLS), sleep quality impairment, depression, fatigue, and sleep behavior disorder and to determine the effects of surgery on these parameters in radiculopathy patients resistant to conservative treatment. Methods. The present study included 66 lumbar radiculopathy patients, who were resistant to conservative treatment and had indication of surgery. Five different questionnaires were performed to assess depression (the Beck Depression Inventory (BDI)), sleep quality (the Pittsburgh Sleep Quality Index (PSQI)), fatigue (the Fatigue Severity Scale (FSS)), and presence of RLS and rapid eye movement sleep behavior disorder (RBD). The same questionnaires were also performed on a control group (n = 61). Results. Of the radiculopathy patients, 68.1% had RLS and 92.4% had fatigue. Of the controls, 16.4% had RLS and 59% had fatigue. RBD was present in 8 (12.1%) patients and 3 (4.9%) controls. The PSQI revealed that sleep quality was impaired in 46 (69.7%) patients and 35 (57.4%) controls (P > 0.05). The number of individuals having substantial depression according to the BDI was significantly higher in the patients than in the controls. Conclusions. There was a significant increase in the frequency of RLS, which was significantly decreased in the postoperative period in the radiculopathy patients. PMID:25110396

  16. Space shuttle flying qualities and criteria assessment

    NASA Technical Reports Server (NTRS)

    Myers, T. T.; Johnston, D. E.; Mcruer, Duane T.

    1987-01-01

    Work accomplished under a series of study tasks for the Flying Qualities and Flight Control Systems Design Criteria Experiment (OFQ) of the Shuttle Orbiter Experiments Program (OEX) is summarized. The tasks involved review of applicability of existing flying quality and flight control system specification and criteria for the Shuttle; identification of potentially crucial flying quality deficiencies; dynamic modeling of the Shuttle Orbiter pilot/vehicle system in the terminal flight phases; devising a nonintrusive experimental program for extraction and identification of vehicle dynamics, pilot control strategy, and approach and landing performance metrics, and preparation of an OEX approach to produce a data archive and optimize use of the data to develop flying qualities for future space shuttle craft in general. Analytic modeling of the Orbiter's unconventional closed-loop dynamics in landing, modeling pilot control strategies, verification of vehicle dynamics and pilot control strategy from flight data, review of various existent or proposed aircraft flying quality parameters and criteria in comparison with the unique dynamic characteristics and control aspects of the Shuttle in landing; and finally a summary of conclusions and recommendations for developing flying quality criteria and design guides for future Shuttle craft.

  17. Telecommunications Systems Career Ladder, AFSC 307XO.

    DTIC Science & Technology

    1981-01-01

    standard test tone levels perform impulse noise tests make in-service or out-of- service quality check.s on composite signal transmission levels Even...service or out-of- service quality control (QC) reports maintain trouble and restoration record forms (DD Form 1443) direct circuit or system checks...include: perform fault isolation on analog circuits make in-service or out-of- service quality checks on voice frequency carrier telegraph (VFCT) terminals

  18. Quality, and not just quantity, of education accounts for differences in psychometric performance between African Americans and White Non-Hispanics with Alzheimer’s disease

    PubMed Central

    Chin, Alexander L.; Negash, Selam; Xie, Sharon; Arnold, Steven E.; Hamilton, Roy

    2013-01-01

    The effect of race on cognitive test performance in the evaluation of Alzheimer’s disease (AD) remains controversial. One factor that may contribute substantially to differences in cognitive test performance in diverse populations is education. The current study examined the extent to which quality of education, even after controlling for formal years of education, accounts for differences in cognitive performance between African Americans and White Non-Hispanics (WNHs). The retrospective cohort included 244 patients diagnosed with AD who self-identified as African Americans (n=51) or WNHs (n=193). The Wechsler Test of Adult Reading (WTAR) was used as an estimate of quality of education. In an analysis that controlled for traditional demographics, including age, sex, and years of formal education, African Americans scored significantly lower than WNHs on the Mini-Mental State Examination, as well as on neuropsychological tests of memory, attention, and language. However, after also adjusting for reading level, all previously observed differences were significantly attenuated. The attenuating effect remained even after controlling for disease severity, indicating that reading scores are not confounded by severity of dementia. These findings suggest that quality, and not just quantity, of education needs to be taken into account when assessing cognitive performance in African Americans with AD. PMID:22300593

  19. Synthesis and quality control of fluorodeoxyglucose and performance assessment of Siemens MicroFocus 220 small animal PET scanner

    NASA Astrophysics Data System (ADS)

    Phaterpekar, Siddhesh Nitin

    The scope of this article is to cover the synthesis and quality control procedures involved in production of Fludeoxyglucose (18F--FDG). The article also describes the cyclotron production of 18F radioisotope and gives a brief overview on operations and working of a fixed energy medical cyclotron. The quality control procedures for FDG involve radiochemical and radionuclidic purity tests, pH tests, chemical purity tests, sterility tests, endotoxin tests. Each of these procedures were carried out for multiple batches of FDG with a passing rate of 95% among 20 batches. The article also covers the quality assurance steps for the Siemens MicroPET Focus 220 Scanner using a Jaszczak phantom. We have carried out spatial resolution tests on the scanner, with an average transaxial resolution of 1.775mm with 2-3mm offset. Tests involved detector efficiency, blank scan sinograms and transmission sinograms. A series of radioactivity distribution tests are also carried out on a uniform phantom, denoting the variations in radioactivity and uniformity by using cylindrical ROIs in the transverse region of the final image. The purpose of these quality control tests is to make sure the manufactured FDG is biocompatible with the human body. Quality assurance tests are carried on PET scanners for efficient performance, and to make sure the quality of images acquired is according to the radioactivity distribution in the subject of interest.

  20. ASVCP quality assurance guidelines: control of general analytical factors in veterinary laboratories.

    PubMed

    Flatland, Bente; Freeman, Kathy P; Friedrichs, Kristen R; Vap, Linda M; Getzy, Karen M; Evans, Ellen W; Harr, Kendal E

    2010-09-01

    Owing to lack of governmental regulation of veterinary laboratory performance, veterinarians ideally should demonstrate a commitment to self-monitoring and regulation of laboratory performance from within the profession. In response to member concerns about quality management in veterinary laboratories, the American Society for Veterinary Clinical Pathology (ASVCP) formed a Quality Assurance and Laboratory Standards (QAS) committee in 1996. This committee recently published updated and peer-reviewed Quality Assurance Guidelines on the ASVCP website. The Quality Assurance Guidelines are intended for use by veterinary diagnostic laboratories and veterinary research laboratories that are not covered by the US Food and Drug Administration Good Laboratory Practice standards (Code of Federal Regulations Title 21, Chapter 58). The guidelines have been divided into 3 reports on 1) general analytic factors for veterinary laboratory performance and comparisons, 2) hematology and hemostasis, and 3) clinical chemistry, endocrine assessment, and urinalysis. This report documents recommendations for control of general analytical factors within veterinary clinical laboratories and is based on section 2.1 (Analytical Factors Important In Veterinary Clinical Pathology, General) of the newly revised ASVCP QAS Guidelines. These guidelines are not intended to be all-inclusive; rather, they provide minimum guidelines for quality assurance and quality control for veterinary laboratory testing. It is hoped that these guidelines will provide a basis for laboratories to assess their current practices, determine areas for improvement, and guide continuing professional development and education efforts. ©2010 American Society for Veterinary Clinical Pathology.

  1. Sigma metrics as a tool for evaluating the performance of internal quality control in a clinical chemistry laboratory.

    PubMed

    Kumar, B Vinodh; Mohan, Thuthi

    2018-01-01

    Six Sigma is one of the most popular quality management system tools employed for process improvement. The Six Sigma methods are usually applied when the outcome of the process can be measured. This study was done to assess the performance of individual biochemical parameters on a Sigma Scale by calculating the sigma metrics for individual parameters and to follow the Westgard guidelines for appropriate Westgard rules and levels of internal quality control (IQC) that needs to be processed to improve target analyte performance based on the sigma metrics. This is a retrospective study, and data required for the study were extracted between July 2015 and June 2016 from a Secondary Care Government Hospital, Chennai. The data obtained for the study are IQC - coefficient of variation percentage and External Quality Assurance Scheme (EQAS) - Bias% for 16 biochemical parameters. For the level 1 IQC, four analytes (alkaline phosphatase, magnesium, triglyceride, and high-density lipoprotein-cholesterol) showed an ideal performance of ≥6 sigma level, five analytes (urea, total bilirubin, albumin, cholesterol, and potassium) showed an average performance of <3 sigma level and for level 2 IQCs, same four analytes of level 1 showed a performance of ≥6 sigma level, and four analytes (urea, albumin, cholesterol, and potassium) showed an average performance of <3 sigma level. For all analytes <6 sigma level, the quality goal index (QGI) was <0.8 indicating the area requiring improvement to be imprecision except cholesterol whose QGI >1.2 indicated inaccuracy. This study shows that sigma metrics is a good quality tool to assess the analytical performance of a clinical chemistry laboratory. Thus, sigma metric analysis provides a benchmark for the laboratory to design a protocol for IQC, address poor assay performance, and assess the efficiency of existing laboratory processes.

  2. Primary display latency criteria based on flying qualities and performance data

    NASA Technical Reports Server (NTRS)

    Funk, John D., Jr.; Beck, Corin P.; Johns, John B.

    1993-01-01

    With a pilots' increasing use of visual cue augmentation, much requiring extensive pre-processing, there is a need to establish criteria for new avionics/display design. The timeliness and synchronization of the augmented cues is vital to ensure the performance quality required for precision mission task elements (MTEs) where augmented cues are the primary source of information to the pilot. Processing delays incurred while transforming sensor-supplied flight information into visual cues are unavoidable. Relationships between maximum control system delays and associated flying qualities levels are documented in MIL-F-83300 and MIL-F-8785. While cues representing aircraft status may be just as vital to the pilot as prompt control response for operations in instrument meteorological conditions, presently, there are no specification requirements on avionics system latency. To produce data relating avionics system latency to degradations in flying qualities, the Navy conducted two simulation investigations. During the investigations, flying qualities and performance data were recorded as simulated avionics system latency was varied. Correlated results of the investigation indicates that there is a detrimental impact of latency on flying qualities. Analysis of these results and consideration of key factors influencing their application indicate that: (1) Task performance degrades and pilot workload increases as latency is increased. Inconsistency in task performance increases as latency increases. (2) Latency reduces the probability of achieving Level 1 handling qualities with avionics system latency as low as 70 ms. (3) The data suggest that the achievement of desired performance will be ensured only at display latency values below 120 ms. (4) These data also suggest that avoidance of inadequate performance will be ensured only at display latency values below 150 ms.

  3. An introduction to statistical process control in research proteomics.

    PubMed

    Bramwell, David

    2013-12-16

    Statistical process control is a well-established and respected method which provides a general purpose, and consistent framework for monitoring and improving the quality of a process. It is routinely used in many industries where the quality of final products is critical and is often required in clinical diagnostic laboratories [1,2]. To date, the methodology has been little utilised in research proteomics. It has been shown to be capable of delivering quantitative QC procedures for qualitative clinical assays [3] making it an ideal methodology to apply to this area of biological research. To introduce statistical process control as an objective strategy for quality control and show how it could be used to benefit proteomics researchers and enhance the quality of the results they generate. We demonstrate that rules which provide basic quality control are easy to derive and implement and could have a major impact on data quality for many studies. Statistical process control is a powerful tool for investigating and improving proteomics research work-flows. The process of characterising measurement systems and defining control rules forces the exploration of key questions that can lead to significant improvements in performance. This work asserts that QC is essential to proteomics discovery experiments. Every experimenter must know the current capabilities of their measurement system and have an objective means for tracking and ensuring that performance. Proteomic analysis work-flows are complicated and multi-variate. QC is critical for clinical chemistry measurements and huge strides have been made in ensuring the quality and validity of results in clinical biochemistry labs. This work introduces some of these QC concepts and works to bridge their use from single analyte QC to applications in multi-analyte systems. This article is part of a Special Issue entitled: Standardization and Quality Control in Proteomics. Copyright © 2013 The Author. Published by Elsevier B.V. All rights reserved.

  4. Further Development, Support and Enhancement of CONDUIT

    NASA Technical Reports Server (NTRS)

    Veronica, Moldoveanu; Levine, William S.

    1999-01-01

    From the first airplanes steered by handles, wheels, and pedals to today's advanced aircraft, there has been a century of revolutionary inventions, all of them contributing to flight quality. The stability and controllability of aircraft as they appear to a pilot are called flying or handling qualities. Many years after the first airplanes flew, flying qualities were identified and ranked from desirable to unsatisfactory. Later on engineers developed design methods to satisfy these practical criteria. CONDUIT, which stands for Control Designer's Unified Interface, is a modern software package that provides a methodology for optimization of flight control systems in order to improve the flying qualities. CONDUIT is dependent on an the optimization engine called CONSOL-OPTCAD (C-O). C-O performs multicriterion parametric optimization. C-O was successfully tested on a variety of control problems. The optimization-based computational system, C-O, requires a particular control system description as a MATLAB file and possesses the ability to modify the vector of design parameters in an attempt to satisfy performance objectives and constraints specified by the designer, in a C-type file. After the first optimization attempts on the UH-60A control system, an early interface system, named GIFCORCODE (Graphical Interface for CONSOL-OPTCAD for Rotorcraft Controller Design) was created.

  5. String Stability of a Linear Formation Flight Control System

    NASA Technical Reports Server (NTRS)

    Allen, Michael J.; Ryan, Jack; Hanson, Curtis E.; Parle, James F.

    2002-01-01

    String stability analysis of an autonomous formation flight system was performed using linear and nonlinear simulations. String stability is a measure of how position errors propagate from one vehicle to another in a cascaded system. In the formation flight system considered here, each i(sup th) aircraft uses information from itself and the preceding ((i-1)(sup th)) aircraft to track a commanded relative position. A possible solution for meeting performance requirements with such a system is to allow string instability. This paper explores two results of string instability and outlines analysis techniques for string unstable systems. The three analysis techniques presented here are: linear, nonlinear formation performance, and ride quality. The linear technique was developed from a worst-case scenario and could be applied to the design of a string unstable controller. The nonlinear formation performance and ride quality analysis techniques both use nonlinear formation simulation. Three of the four formation-controller gain-sets analyzed in this paper were limited more by ride quality than by performance. Formations of up to seven aircraft in a cascaded formation could be used in the presence of light gusts with this string unstable system.

  6. Effect of flashlight guidance on manual ventilation performance in cardiopulmonary resuscitation: A randomized controlled simulation study.

    PubMed

    Kim, Ji Hoon; Beom, Jin Ho; You, Je Sung; Cho, Junho; Min, In Kyung; Chung, Hyun Soo

    2018-01-01

    Several auditory-based feedback devices have been developed to improve the quality of ventilation performance during cardiopulmonary resuscitation (CPR), but their effectiveness has not been proven in actual CPR situations. In the present study, we investigated the effectiveness of visual flashlight guidance in maintaining high-quality ventilation performance. We conducted a simulation-based, randomized, parallel trial including 121 senior medical students. All participants were randomized to perform ventilation during 2 minutes of CPR with or without flashlight guidance. For each participant, we measured mean ventilation rate as a primary outcome and ventilation volume, inspiration velocity, and ventilation interval as secondary outcomes using a computerized device system. Mean ventilation rate did not significantly differ between flashlight guidance and control groups (P = 0.159), but participants in the flashlight guidance group exhibited significantly less variation in ventilation rate than participants in the control group (P<0.001). Ventilation interval was also more regular among participants in the flashlight guidance group. Our results demonstrate that flashlight guidance is effective in maintaining a constant ventilation rate and interval. If confirmed by further studies in clinical practice, flashlight guidance could be expected to improve the quality of ventilation performed during CPR.

  7. A multiple objective optimization approach to quality control

    NASA Technical Reports Server (NTRS)

    Seaman, Christopher Michael

    1991-01-01

    The use of product quality as the performance criteria for manufacturing system control is explored. The goal in manufacturing, for economic reasons, is to optimize product quality. The problem is that since quality is a rather nebulous product characteristic, there is seldom an analytic function that can be used as a measure. Therefore standard control approaches, such as optimal control, cannot readily be applied. A second problem with optimizing product quality is that it is typically measured along many dimensions: there are many apsects of quality which must be optimized simultaneously. Very often these different aspects are incommensurate and competing. The concept of optimality must now include accepting tradeoffs among the different quality characteristics. These problems are addressed using multiple objective optimization. It is shown that the quality control problem can be defined as a multiple objective optimization problem. A controller structure is defined using this as the basis. Then, an algorithm is presented which can be used by an operator to interactively find the best operating point. Essentially, the algorithm uses process data to provide the operator with two pieces of information: (1) if it is possible to simultaneously improve all quality criteria, then determine what changes to the process input or controller parameters should be made to do this; and (2) if it is not possible to improve all criteria, and the current operating point is not a desirable one, select a criteria in which a tradeoff should be made, and make input changes to improve all other criteria. The process is not operating at an optimal point in any sense if no tradeoff has to be made to move to a new operating point. This algorithm ensures that operating points are optimal in some sense and provides the operator with information about tradeoffs when seeking the best operating point. The multiobjective algorithm was implemented in two different injection molding scenarios: tuning of process controllers to meet specified performance objectives and tuning of process inputs to meet specified quality objectives. Five case studies are presented.

  8. ATAD control goals through the analysis of process variables and evaluation of quality, production and cost.

    PubMed

    Nájera, S; Gil-Martínez, M; Zambrano, J A

    2015-01-01

    The aim of this paper is to establish and quantify different operational goals and control strategies in autothermal thermophilic aerobic digestion (ATAD). This technology appears as an alternative to conventional sludge digestion systems. During the batch-mode reaction, high temperatures promote sludge stabilization and pasteurization. The digester temperature is usually the only online, robust, measurable variable. The average temperature can be regulated by manipulating both the air injection and the sludge retention time. An improved performance of diverse biochemical variables can be achieved through proper manipulation of these inputs. However, a better quality of treated sludge usually implies major operating costs or a lower production rate. Thus, quality, production and cost indices are defined to quantify the outcomes of the treatment. Based on these, tradeoff control strategies are proposed and illustrated through some examples. This paper's results are relevant to guide plant operators, to design automatic control systems and to compare or evaluate the control performance on ATAD systems.

  9. [Strategies and development of quality assurance and control in the ELSA-Brasil].

    PubMed

    Schmidt, Maria Inês; Griep, Rosane Härter; Passos, Valéria Maria; Luft, Vivian Cristine; Goulart, Alessandra Carvalho; Menezes, Greice Maria de Souza; Molina, Maria del Carmen Bisi; Vigo, Alvaro; Nunes, Maria Angélica

    2013-06-01

    The ELSA-Brasil (Estudo Longitudinal de Saúde do Adulto - Brazilian Longitudinal Study for Adult Health) is a cohort study composed of 15,105 adults followed up in order to assess the development of chronic diseases, especially diabetes and cardiovascular disease. Its size, multicenter nature and the diversity of measurements required effective and efficient mechanisms of quality assurance and control. The main quality assurance activities (those developed before data collection) were: careful selection of research instruments, centralized training and certification, pretesting and pilot studies, and preparation of operation manuals for the procedures. Quality control activities (developed during data collection and processing) were performed more intensively at the beginning, when routines had not been established yet. The main quality control activities were: periodic observation of technicians, test-retest studies, data monitoring, network of supervisors, and cross visits. Data that estimate the reliability of the obtained information attest that the quality goals have been achieved.

  10. Multi-criteria decision making approaches for quality control of genome-wide association studies.

    PubMed

    Malovini, Alberto; Rognoni, Carla; Puca, Annibale; Bellazzi, Riccardo

    2009-03-01

    Experimental errors in the genotyping phases of a Genome-Wide Association Study (GWAS) can lead to false positive findings and to spurious associations. An appropriate quality control phase could minimize the effects of this kind of errors. Several filtering criteria can be used to perform quality control. Currently, no formal methods have been proposed for taking into account at the same time these criteria and the experimenter's preferences. In this paper we propose two strategies for setting appropriate genotyping rate thresholds for GWAS quality control. These two approaches are based on the Multi-Criteria Decision Making theory. We have applied our method on a real dataset composed by 734 individuals affected by Arterial Hypertension (AH) and 486 nonagenarians without history of AH. The proposed strategies appear to deal with GWAS quality control in a sound way, as they lead to rationalize and make explicit the experimenter's choices thus providing more reproducible results.

  11. [Comparative quality measurements part 3: funnel plots].

    PubMed

    Kottner, Jan; Lahmann, Nils

    2014-02-01

    Comparative quality measurements between organisations or institutions are common. Quality measures need to be standardised and risk adjusted. Random error must also be taken adequately into account. Rankings without consideration of the precision lead to flawed interpretations and enhances "gaming". Application of confidence intervals is one possibility to take chance variation into account. Funnel plots are modified control charts based on Statistical Process Control (SPC) theory. The quality measures are plotted against their sample size. Warning and control limits that are 2 or 3 standard deviations from the center line are added. With increasing group size the precision increases and so the control limits are forming a funnel. Data points within the control limits are considered to show common cause variation; data points outside special cause variation without the focus of spurious rankings. Funnel plots offer data based information about how to evaluate institutional performance within quality management contexts.

  12. Quality controls for gamma cameras and PET cameras: development of a free open-source ImageJ program

    NASA Astrophysics Data System (ADS)

    Carlier, Thomas; Ferrer, Ludovic; Berruchon, Jean B.; Cuissard, Regis; Martineau, Adeline; Loonis, Pierre; Couturier, Olivier

    2005-04-01

    Acquisition data and treatments for quality controls of gamma cameras and Positron Emission Tomography (PET) cameras are commonly performed with dedicated program packages, which are running only on manufactured computers and differ from each other, depending on camera company and program versions. The aim of this work was to develop a free open-source program (written in JAVA language) to analyze data for quality control of gamma cameras and PET cameras. The program is based on the free application software ImageJ and can be easily loaded on any computer operating system (OS) and thus on any type of computer in every nuclear medicine department. Based on standard parameters of quality control, this program includes 1) for gamma camera: a rotation center control (extracted from the American Association of Physics in Medicine, AAPM, norms) and two uniformity controls (extracted from the Institute of Physics and Engineering in Medicine, IPEM, and National Electronic Manufacturers Association, NEMA, norms). 2) For PET systems, three quality controls recently defined by the French Medical Physicist Society (SFPM), i.e. spatial resolution and uniformity in a reconstructed slice and scatter fraction, are included. The determination of spatial resolution (thanks to the Point Spread Function, PSF, acquisition) allows to compute the Modulation Transfer Function (MTF) in both modalities of cameras. All the control functions are included in a tool box which is a free ImageJ plugin and could be soon downloaded from Internet. Besides, this program offers the possibility to save on HTML format the uniformity quality control results and a warning can be set to automatically inform users in case of abnormal results. The architecture of the program allows users to easily add any other specific quality control program. Finally, this toolkit is an easy and robust tool to perform quality control on gamma cameras and PET cameras based on standard computation parameters, is free, run on any type of computer and will soon be downloadable from the net (http://rsb.info.nih.gov/ij/plugins or http://nucleartoolkit.free.fr).

  13. COMP report: CPQR technical quality control guidelines for low-dose-rate permanent seed brachytherapy.

    PubMed

    Beaulieu, Luc; Radford, Dee-Ann; Eduardo Villarreal-Barajas, J

    2018-03-14

    The Canadian Organization of Medical Physicists (COMP), in close partnership with the Canadian Partnership for Quality Radiotherapy (CPQR) has developed a series of Technical Quality Control (TQC) guidelines for radiation treatment equipment. These guidelines outline the performance objectives that equipment should meet in order to ensure an acceptable level of radiation treatment quality. The TQC guidelines have been rigorously reviewed and field tested in a variety of Canadian radiation treatment facilities. The development process enables rapid review and update to keep the guidelines current with changes in technology. This article contains detailed performance objectives and safety criteria for low-dose-rate (LDR) permanent seed brachytherapy. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  14. QC-ART: A tool for real-time quality control assessment of mass spectrometry-based proteomics data.

    PubMed

    Stanfill, Bryan A; Nakayasu, Ernesto S; Bramer, Lisa M; Thompson, Allison M; Ansong, Charles K; Clauss, Therese; Gritsenko, Marina A; Monroe, Matthew E; Moore, Ronald J; Orton, Daniel J; Piehowski, Paul D; Schepmoes, Athena A; Smith, Richard D; Webb-Robertson, Bobbie-Jo; Metz, Thomas O

    2018-04-17

    Liquid chromatography-mass spectrometry (LC-MS)-based proteomics studies of large sample cohorts can easily require from months to years to complete. Acquiring consistent, high-quality data in such large-scale studies is challenging because of normal variations in instrumentation performance over time, as well as artifacts introduced by the samples themselves, such as those due to collection, storage and processing. Existing quality control methods for proteomics data primarily focus on post-hoc analysis to remove low-quality data that would degrade downstream statistics; they are not designed to evaluate the data in near real-time, which would allow for interventions as soon as deviations in data quality are detected.  In addition to flagging analyses that demonstrate outlier behavior, evaluating how the data structure changes over time can aide in understanding typical instrument performance or identify issues such as a degradation in data quality due to the need for instrument cleaning and/or re-calibration.  To address this gap for proteomics, we developed Quality Control Analysis in Real-Time (QC-ART), a tool for evaluating data as they are acquired in order to dynamically flag potential issues with instrument performance or sample quality.  QC-ART has similar accuracy as standard post-hoc analysis methods with the additional benefit of real-time analysis.  We demonstrate the utility and performance of QC-ART in identifying deviations in data quality due to both instrument and sample issues in near real-time for LC-MS-based plasma proteomics analyses of a sample subset of The Environmental Determinants of Diabetes in the Young cohort. We also present a case where QC-ART facilitated the identification of oxidative modifications, which are often underappreciated in proteomic experiments. Published under license by The American Society for Biochemistry and Molecular Biology, Inc.

  15. A multiyear quality control study of alpha-track radon monitors.

    PubMed

    Pearson, M D; Martz, D E; George, J L; Langner, G H

    1992-01-01

    Quality control exposures of commercial alpha-track radon monitors have been conducted approximately weekly at the U.S. Department of Energy (DOE) Grand Junction Projects Office since early 1987 in support of DOE remedial action programs. The results of these exposures provide a historical record of the comparative performances of these radon monitors.

  16. 21 CFR 111.140 - Under this subpart F, what records must you make and keep?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... and making a disposition decision and written procedures for approving or rejecting any reprocessing... perform the quality control operation, who conducted the material review and made the disposition decision... System: Requirements for Quality Control § 111.140 Under this subpart F, what records must you make and...

  17. Tools for Schools: Filtration for Improved Air Quality. Technical Services Bulletin.

    ERIC Educational Resources Information Center

    2001

    This product bulletin addresses air pollution control in educational facilities to enhance educational performance, provides air quality recommendations for schools, and examines the filtration needs of various school areas. The types of air particles typically present are highlighted, and the use of proper filtration to control gases and vapors…

  18. 76 FR 64086 - Availability of FY 10 Grantee Performance Evaluation Reports for the Eight States of EPA Region 4...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-17

    ... Conservation Resources, FL; Louisville Metro Air Pollution Control District, KY; Forsyth County Environmental... Carolina Regional Air Quality Agency, NC; Chattanooga-Hamilton County Air Pollution Control Bureau, TN; Shelby County Health Department, TN; Knox County Department of Air Quality Management, TN; and...

  19. 77 FR 52022 - Availability of FY 11 Grantee Performance Evaluation Reports for the Eight States of EPA Region 4...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-28

    ... Conservation Resources, FL; Louisville Metro Air Pollution Control District, KY; Forsyth County Environmental... Carolina Regional Air Quality Agency, NC; Chattanooga-Hamilton County Air Pollution Control Bureau, TN; Shelby County Health Department, TN; Knox County Department of Air Quality Management, TN; and...

  20. 75 FR 6597 - Determination to Approve Alternative Final Cover Request for the Lake County, MT Landfill...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-10

    ... layer, a 24-inch native sand layer, an 18-inch imported silt evapotranspiration layer, and a 6-inch... Quality Assurance & Control Plan'' for the closure project that specifies that testing will be performed... described in detail in the ``Construction Quality Assurance & Control Plan.'' II. EPA's Action A...

  1. BatMass: a Java Software Platform for LC-MS Data Visualization in Proteomics and Metabolomics.

    PubMed

    Avtonomov, Dmitry M; Raskind, Alexander; Nesvizhskii, Alexey I

    2016-08-05

    Mass spectrometry (MS) coupled to liquid chromatography (LC) is a commonly used technique in metabolomic and proteomic research. As the size and complexity of LC-MS-based experiments grow, it becomes increasingly more difficult to perform quality control of both raw data and processing results. In a practical setting, quality control steps for raw LC-MS data are often overlooked, and assessment of an experiment's success is based on some derived metrics such as "the number of identified compounds". The human brain interprets visual data much better than plain text, hence the saying "a picture is worth a thousand words". Here, we present the BatMass software package, which allows for performing quick quality control of raw LC-MS data through its fast visualization capabilities. It also serves as a testbed for developers of LC-MS data processing algorithms by providing a data access library for open mass spectrometry file formats and a means of visually mapping processing results back to the original data. We illustrate the utility of BatMass with several use cases of quality control and data exploration.

  2. BatMass: a Java software platform for LC/MS data visualization in proteomics and metabolomics

    PubMed Central

    Avtonomov, Dmitry; Raskind, Alexander; Nesvizhskii, Alexey I.

    2017-01-01

    Mass spectrometry (MS) coupled to liquid chromatography (LC) is a commonly used technique in metabolomic and proteomic research. As the size and complexity of LC/MS based experiments grow, it becomes increasingly more difficult to perform quality control of both raw data and processing results. In a practical setting, quality control steps for raw LC/MS data are often overlooked and assessment of an experiment's success is based on some derived metrics such as “the number of identified compounds”. Human brain interprets visual data much better than plain text, hence the saying “a picture is worth a thousand words”. Here we present BatMass software package which allows to perform quick quality control of raw LC/MS data through its fast visualization capabilities. It also serves as a testbed for developers of LC/MS data processing algorithms by providing a data access library for open mass spectrometry file formats and a means of visually mapping processing results back to the original data. We illustrate the utility of BatMass with several use cases of quality control and data exploration. PMID:27306858

  3. Severe postpartum haemorrhage after vaginal delivery: a statistical process control chart to report seven years of continuous quality improvement.

    PubMed

    Dupont, Corinne; Occelli, Pauline; Deneux-Tharaux, Catherine; Touzet, Sandrine; Duclos, Antoine; Bouvier-Colle, Marie-Hélène; Rudigoz, René-Charles; Huissoud, Cyril

    2014-07-01

    Severe postpartum haemorrhage after vaginal delivery: a statistical process control chart to report seven years of continuous quality improvement To use statistical process control charts to describe trends in the prevalence of severe postpartum haemorrhage after vaginal delivery. This assessment was performed 7 years after we initiated a continuous quality improvement programme that began with regular criteria-based audits Observational descriptive study, in a French maternity unit in the Rhône-Alpes region. Quarterly clinical audit meetings to analyse all cases of severe postpartum haemorrhage after vaginal delivery and provide feedback on quality of care with statistical process control tools. The primary outcomes were the prevalence of severe PPH after vaginal delivery and its quarterly monitoring with a control chart. The secondary outcomes included the global quality of care for women with severe postpartum haemorrhage, including the performance rate of each recommended procedure. Differences in these variables between 2005 and 2012 were tested. From 2005 to 2012, the prevalence of severe postpartum haemorrhage declined significantly, from 1.2% to 0.6% of vaginal deliveries (p<0.001). Since 2010, the quarterly rate of severe PPH has not exceeded the upper control limits, that is, been out of statistical control. The proportion of cases that were managed consistently with the guidelines increased for all of their main components. Implementation of continuous quality improvement efforts began seven years ago and used, among other tools, statistical process control charts. During this period, the prevalence of severe postpartum haemorrhage after vaginal delivery has been reduced by 50%. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  4. Interaction of feel system and flight control system dynamics on lateral flying qualities

    NASA Technical Reports Server (NTRS)

    Bailey, Randall E.; Powers, Bruce G.; Shafer, Mary F.

    1988-01-01

    An investigation of feel system and flight control system dynamics on lateral flying qualities was conducted using the variable stability USAF NT-33 aircraft. Experimental variations in feel system natural frequency, force-deflection gradient, control system command architecture type, flight control system filter frequency, and control system delay were made. The experiment data include pilot ratings using the Cooper-Harper (1969) rating scale, pilot comments, and tracking performance statistic. Three test pilots served as evaluators. The data indicate that as the feel system natural frequency is reduced lateral flying qualities degrade. At the slowest feel system frequency, the closed-loop response becomes nonlinear with a 'bobweight' effect apparent in the feel system. Feel system influences were essentially independent of the control system architecture. The flying qualities influence due to the feel system was different than when the identical dynamic systenm was used as a flight control system element.

  5. Influence of quality control variables on failure of graphite/epoxy under extreme moisture conditions

    NASA Technical Reports Server (NTRS)

    Clements, L. L.; Lee, P. R.

    1980-01-01

    Tension tests on graphite/epoxy composites were performed to determine the influence of various quality control variables on failure strength as a function of moisture and moderate temperatures. The extremely high and low moisture contents investigated were found to have less effect upon properties than did temperature or the quality control variables of specimen flaws and prepreg batch to batch variations. In particular, specimen flaws were found to drastically reduce the predicted strength of the composite, whereas specimens from different batches of prepreg displayed differences in strength as a function of temperature and extreme moisture exposure. The findings illustrate the need for careful specimen preparation, studies of flaw sensitivity, and careful quality control in any study of composite materials.

  6. [Performance of Grass Swales for Controlling Pollution of Roadway Runoff in Field Experiments].

    PubMed

    Huang, Jun-jie; Shen, Qing-ran; Li, Tian

    2015-06-01

    Two different styles of grass swales were built in new Binhu region of Hefei city to monitor the flux and quality of the influent and effluent water under actual precipitation conditions, in order to evaluate the performance of water quality purification and pollution load control for roadway runoff. The results showed that both of the grass swales could effectively remove the pollutants such as TSS, COD, Pb, Cu, Cd, Zn in roadway runoff; the median EMC removal efficiencies of TSS and COD were 67.1%, 46.7% respectively,for facility I, and the median EMC removal efficiencies of TSS and COD were 78.6%, 58.6% respectively, for facility II; the concentrations of Pb, Cu, Zn in the effluent of facility II could meet the requirements of the surface water quality class V; release of nitrogen and phosphorus occurred in both facilities I and I[ in several rainfall events, mainly in heavy storms; the removal efficiencies of TP in the two grass swales were improved with the increase of influent concentration; the mean removal efficiencies of TP in facilities I and II were 14.7% and 45.4%, respectively; the load control performance of facility II for pollutants such as TSS, COD, TP, TN, NH4+ -N and NO3- -N was better than that of facility I; in the district with poor soil permeability and low ground slope, application of dry swale could achieve better performance in water quality control and pollution load reduction of roadway runoff.

  7. Development of an environmental chamber for evaluating the performance of low-cost air quality sensors under controlled conditions

    NASA Astrophysics Data System (ADS)

    Papapostolou, Vasileios; Zhang, Hang; Feenstra, Brandon J.; Polidori, Andrea

    2017-12-01

    A state-of-the-art integrated chamber system has been developed for evaluating the performance of low-cost air quality sensors. The system contains two professional grade chamber enclosures. A 1.3 m3 stainless-steel outer chamber and a 0.11 m3 Teflon-coated stainless-steel inner chamber are used to create controlled aerosol and gaseous atmospheres, respectively. Both chambers are temperature and relative humidity controlled with capability to generate a wide range of environmental conditions. The system is equipped with an integrated zero-air system, an ozone and two aerosol generation systems, a dynamic dilution calibrator, certified gas cylinders, an array of Federal Reference Method (FRM), Federal Equivalent Method (FEM), and Best Available Technology (BAT) reference instruments and an automated control and sequencing software. Our experiments have demonstrated that the chamber system is capable of generating stable and reproducible aerosol and gas concentrations at low, medium, and high levels. This paper discusses the development of the chamber system along with the methods used to quantitatively evaluate sensor performance. Considering that a significant number of academic and research institutions, government agencies, public and private institutions, and individuals are becoming interested in developing and using low-cost air quality sensors, it is important to standardize the procedures used to evaluate their performance. The information discussed herein provides a roadmap for entities who are interested in characterizing air quality sensors in a rigorous, systematic and reproducible manner.

  8. Zerodur polishing process for high surface quality and high efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tesar, A.; Fuchs, B.

    1992-08-01

    Zerodur is a glass-ceramic composite importance in applications where temperature instabilities influence optical and mechanical performance, such as in earthbound and spaceborne telescope mirror substrates. Polished Zerodur surfaces of high quality have been required for laser gyro mirrors. Polished surface quality of substrates affects performance of high reflection coatings. Thus, the interest in improving Zerodur polished surface quality has become more general. Beyond eliminating subsurface damage, high quality surfaces are produced by reducing the amount of hydrated material redeposited on the surface during polishing. With the proper control of polishing parameters, such surfaces exhibit roughnesses of

  9. Process-based quality for thermal spray via feedback control

    NASA Astrophysics Data System (ADS)

    Dykhuizen, R. C.; Neiser, R. A.

    2006-09-01

    Quality control of a thermal spray system manufacturing process is difficult due to the many input variables that need to be controlled. Great care must be taken to ensure that the process remains constant to obtain a consistent quality of the parts. Control is greatly complicated by the fact that measurement of particle velocities and temperatures is a noisy stochastic process. This article illustrates the application of quality control concepts to a wire flame spray process. A central feature of the real-time control system is an automatic feedback control scheme that provides fine adjustments to ensure that uncontrolled variations are accommodated. It is shown how the control vectors can be constructed from simple process maps to independently control particle velocity and temperature. This control scheme is shown to perform well in a real production environment. We also demonstrate that slight variations in the feed wire curvature can greatly influence the process. Finally, the geometry of the spray system and sensor must remain constant for the best reproducibility.

  10. An adaptive toolkit for image quality evaluation in system performance test of digital breast tomosynthesis

    NASA Astrophysics Data System (ADS)

    Zhang, Guozhi; Petrov, Dimitar; Marshall, Nicholas; Bosmans, Hilde

    2017-03-01

    Digital breast tomosynthesis (DBT) is a relatively new diagnostic imaging modality for women. Currently, various models of DBT systems are available on the market and the number of installations is rapidly increasing. EUREF, the European Reference Organization for Quality Assured Breast Screening and Diagnostic Services, has proposed a preliminary Guideline - protocol for the quality control of the physical and technical aspects of digital breast tomosynthesis systems, with an ultimate aim of providing limiting values guaranteeing proper performance for different applications of DBT. In this work, we introduce an adaptive toolkit developed in accordance with this guideline to facilitate the process of image quality evaluation in DBT performance test. This toolkit implements robust algorithms to quantify various technical parameters of DBT images and provides a convenient user interface in practice. Each test is built into a separate module with configurations set corresponding to the European guideline, which can be easily adapted to different settings and extended with additional tests. This toolkit largely improves the efficiency for image quality evaluation of DBT. It is also going to evolve with the development of protocols in quality control of DBT systems.

  11. Median of patient results as a tool for assessment of analytical stability.

    PubMed

    Jørgensen, Lars Mønster; Hansen, Steen Ingemann; Petersen, Per Hyltoft; Sölétormos, György

    2015-06-15

    In spite of the well-established external quality assessment and proficiency testing surveys of analytical quality performance in laboratory medicine, a simple tool to monitor the long-term analytical stability as a supplement to the internal control procedures is often needed. Patient data from daily internal control schemes was used for monthly appraisal of the analytical stability. This was accomplished by using the monthly medians of patient results to disclose deviations from analytical stability, and by comparing divergences with the quality specifications for allowable analytical bias based on biological variation. Seventy five percent of the twenty analytes achieved on two COBASs INTEGRA 800 instruments performed in accordance with the optimum and with the desirable specifications for bias. Patient results applied in analytical quality performance control procedures are the most reliable sources of material as they represent the genuine substance of the measurements and therefore circumvent the problems associated with non-commutable materials in external assessment. Patient medians in the monthly monitoring of analytical stability in laboratory medicine are an inexpensive, simple and reliable tool to monitor the steadiness of the analytical practice. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Effect of poor control of film processors on mammographic image quality.

    PubMed

    Kimme-Smith, C; Sun, H; Bassett, L W; Gold, R H

    1992-11-01

    With the increasingly stringent standards of image quality in mammography, film processor quality control is especially important. Current methods are not sufficient for ensuring good processing. The authors used a sensitometer and densitometer system to evaluate the performance of 22 processors at 16 mammographic facilities. Standard sensitometric values of two films were established, and processor performance was assessed for variations from these standards. Developer chemistry of each processor was analyzed and correlated with its sensitometric values. Ten processors were retested, and nine were found to be out of calibration. The developer components of hydroquinone, sulfites, bromide, and alkalinity varied the most, and low concentrations of hydroquinone were associated with lower average gradients at two facilities. Use of the sensitometer and densitometer system helps identify out-of-calibration processors, but further study is needed to correlate sensitometric values with developer component values. The authors believe that present quality control would be improved if sensitometric or other tests could be used to identify developer components that are out of calibration.

  13. Isolated Power Generation System Using Permanent Magnet Synchronous Generator with Improved Power Quality

    NASA Astrophysics Data System (ADS)

    Arya, Sabha Raj; Patel, Ashish; Giri, Ashutosh

    2018-06-01

    This paper deals wind energy based power generation system using Permanent Magnet Synchronous Generator (PMSG). It is controlled using advanced enhanced phase-lock loop for power quality features using distribution static compensator to eliminate the harmonics and to provide KVAR compensation as well as load balancing. It also manages rated potential at the point of common interface under linear and non-linear loads. In order to have better efficiency and reliable operation of PMSG driven by wind turbine, it is necessary to analyze the governing equation of wind based turbine and PMSG under fixed and variable wind speed. For handling power quality problems, power electronics based shunt connected custom power device is used in three wire system. The simulations in MATLAB/Simulink environment have been carried out in order to demonstrate this model and control approach used for the power quality enhancement. The performance results show the adequate performance of PMSG based power generation system and control algorithm.

  14. Isolated Power Generation System Using Permanent Magnet Synchronous Generator with Improved Power Quality

    NASA Astrophysics Data System (ADS)

    Arya, Sabha Raj; Patel, Ashish; Giri, Ashutosh

    2018-03-01

    This paper deals wind energy based power generation system using Permanent Magnet Synchronous Generator (PMSG). It is controlled using advanced enhanced phase-lock loop for power quality features using distribution static compensator to eliminate the harmonics and to provide KVAR compensation as well as load balancing. It also manages rated potential at the point of common interface under linear and non-linear loads. In order to have better efficiency and reliable operation of PMSG driven by wind turbine, it is necessary to analyze the governing equation of wind based turbine and PMSG under fixed and variable wind speed. For handling power quality problems, power electronics based shunt connected custom power device is used in three wire system. The simulations in MATLAB/Simulink environment have been carried out in order to demonstrate this model and control approach used for the power quality enhancement. The performance results show the adequate performance of PMSG based power generation system and control algorithm.

  15. Oral nutritional supplements containing n-3 polyunsaturated fatty acids affect quality of life and functional status in lung cancer patients during multimodality treatment: an RCT

    PubMed Central

    van der Meij, B S; Langius, J A E; Spreeuwenberg, M D; Slootmaker, S M; Paul, M A; Smit, E F; van Leeuwen, P A M

    2012-01-01

    Background/Objectives: Our objective was to investigate effects of an oral nutritional supplement containing n-3 polyunsaturated fatty acids (FAs) on quality of life, performance status, handgrip strength and physical activity in patients with non-small cell lung cancer (NSCLC) undergoing multimodality treatment. Subjects/Methods: In a double-blind experiment, 40 patients with stage III NSCLC were randomised to receive 2 cans/day of a protein- and energy-dense oral nutritional supplement containing n-3 polyunsaturated FAs (2.02 g eicosapentaenoic acid+0.92 g docosahexaenoic acid/day) or an isocaloric control supplement, during multimodality treatment. Quality of life, Karnofsky Performance Status, handgrip strength and physical activity (by wearing an accelerometer) were assessed. Effects of intervention were analysed by generalised estimating equations. P-values <0.05 were regarded as statistically significant. Results: The intervention group reported significantly higher on the quality of life parameters, physical and cognitive function (B=11.6 and B=20.7, P<0.01), global health status (B=12.2, P=0.04) and social function (B=22.1, P=0.04) than the control group after 5 weeks. The intervention group showed a higher Karnofsky Performance Status (B=5.3, P=0.04) than the control group after 3 weeks. Handgrip strength did not significantly differ between groups over time. The intervention group tended to have a higher physical activity than the control group after 3 and 5 weeks (B=6.6, P=0.04 and B=2.5, P=0.05). Conclusion: n-3 Polyunsaturated FAs may beneficially affect quality of life, performance status and physical activity in patients with NSCLC undergoing multimodality treatment. PMID:22234041

  16. Integrated Aerodynamic and Control System Design of Oblique Wing Aircraft. Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Morris, Stephen James

    1990-01-01

    An efficient high speed aircraft design must achieve a high lift to drag ratio at transonic and supersonic speeds. In 1952 Dr. R. T. Jones proved that for any flight Mach number minimum drag at a fixed lift is achieved by an elliptic wing planform with an appropriate oblique sweep angle. Since then, wind tunnel tests and numerical flow models have confirmed that the compressibility drag of oblique wing aircraft is lower than similar symmetrical sweep designs. At oblique sweep angles above thirty degrees the highly asymmetric planform gives rise to aerodynamic and inertia couplings which affect stability and degrade the aircraft's handling qualities. In the case of the NASA-Rockwell Oblique Wing Research Aircraft, attempts to improve the handling qualities by implementing a stability augmentation system have produced unsatisfactory results because of an inherent lack of controllability in the proposed design. The present work focuses on improving the handling qualities of oblique wing aircraft by including aerodynamic configuration parameters as variables in the control system synthesis to provide additional degrees of freedom with which to further decouple the aircraft's response. Handling qualities are measured using a quadratic cost function identical to that considered in optimal control problems, but the controller architecture is not restricted to full state feedback. An optimization procedure is used to simultaneously solve for the aircraft configuration and control gains which maximize a handling qualities measure, while meeting imposed constraints on trim. In some designs wing flexibility is also modeled and reduced order controllers are implemented. Oblique wing aircraft synthesized by this integrated design method show significant improvement in handling qualities when compared to the originally proposed closed loop aircraft. The integrated design synthesis method is then extended to show how handling qualities may be traded for other types of mission performance (drag, weight, etc.). Examples are presented which show how performance can be maximized while maintaining a desired level of handling quality.

  17. Aircraft flight test trajectory control

    NASA Technical Reports Server (NTRS)

    Menon, P. K. A.; Walker, R. A.

    1988-01-01

    Two control law design techniques are compared and the performance of the resulting controllers evaluated. The design requirement is for a flight test trajectory controller (FTTC) capable of closed-loop, outer-loop control of an F-15 aircraft performing high-quality research flight test maneuvers. The maneuver modeling, linearization, and design methodologies utilized in this research, are detailed. The results of applying these FTTCs to a nonlinear F-15 simulation are presented.

  18. Multileaf collimator performance monitoring and improvement using semiautomated quality control testing and statistical process control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Létourneau, Daniel, E-mail: daniel.letourneau@rmp.uh.on.ca; McNiven, Andrea; Keller, Harald

    2014-12-15

    Purpose: High-quality radiation therapy using highly conformal dose distributions and image-guided techniques requires optimum machine delivery performance. In this work, a monitoring system for multileaf collimator (MLC) performance, integrating semiautomated MLC quality control (QC) tests and statistical process control tools, was developed. The MLC performance monitoring system was used for almost a year on two commercially available MLC models. Control charts were used to establish MLC performance and assess test frequency required to achieve a given level of performance. MLC-related interlocks and servicing events were recorded during the monitoring period and were investigated as indicators of MLC performance variations. Methods:more » The QC test developed as part of the MLC performance monitoring system uses 2D megavoltage images (acquired using an electronic portal imaging device) of 23 fields to determine the location of the leaves with respect to the radiation isocenter. The precision of the MLC performance monitoring QC test and the MLC itself was assessed by detecting the MLC leaf positions on 127 megavoltage images of a static field. After initial calibration, the MLC performance monitoring QC test was performed 3–4 times/week over a period of 10–11 months to monitor positional accuracy of individual leaves for two different MLC models. Analysis of test results was performed using individuals control charts per leaf with control limits computed based on the measurements as well as two sets of specifications of ±0.5 and ±1 mm. Out-of-specification and out-of-control leaves were automatically flagged by the monitoring system and reviewed monthly by physicists. MLC-related interlocks reported by the linear accelerator and servicing events were recorded to help identify potential causes of nonrandom MLC leaf positioning variations. Results: The precision of the MLC performance monitoring QC test and the MLC itself was within ±0.22 mm for most MLC leaves and the majority of the apparent leaf motion was attributed to beam spot displacements between irradiations. The MLC QC test was performed 193 and 162 times over the monitoring period for the studied units and recalibration had to be repeated up to three times on one of these units. For both units, rate of MLC interlocks was moderately associated with MLC servicing events. The strongest association with the MLC performance was observed between the MLC servicing events and the total number of out-of-control leaves. The average elapsed time for which the number of out-of-specification or out-of-control leaves was within a given performance threshold was computed and used to assess adequacy of MLC test frequency. Conclusions: A MLC performance monitoring system has been developed and implemented to acquire high-quality QC data at high frequency. This is enabled by the relatively short acquisition time for the images and automatic image analysis. The monitoring system was also used to record and track the rate of MLC-related interlocks and servicing events. MLC performances for two commercially available MLC models have been assessed and the results support monthly test frequency for widely accepted ±1 mm specifications. Higher QC test frequency is however required to maintain tighter specification and in-control behavior.« less

  19. Low bandwidth robust controllers for flight

    NASA Technical Reports Server (NTRS)

    Biezad, Daniel J.; Chou, Hwei-Lan

    1992-01-01

    During the final reporting period (Jun. - Dec. 1992), analyses of the longitudinal and lateral flying qualities were made for propulsive-only flight control (POFC) of a Boeing 720 aircraft model. Performance resulting from compensators developed using Quantitative Feedback Theory (QFT) is documented and analyzed. This report is a first draft of a thesis to be presented by graduate student Hwei-Lan Chou. The final thesis will be presented to NASA when it is completed later this year. The latest landing metrics related to bandwidth criteria and based on the Neal-Smith approach to flying qualities prediction were used in developing performance criteria for the controllers. The compensator designs were tested on the NASA simulator and exhibited adequate performance for piloted flight. There was no significant impact of QFT on performance of the propulsive-only flight controllers in either the longitudinal or lateral modes of flight. This was attributed to the physical limits of thrust available and the engine rate of response, both of whiih severely limited the available bandwidth of the closed-loop system.

  20. Initial Investigation of Reaction Control System Design on Spacecraft Handling Qualities for Earth Orbit Docking

    NASA Technical Reports Server (NTRS)

    Bailey, Randall E.; Jackson, E. Bruce; Goodrich, Kenneth H.; Ragsdale, W. Al; Neuhaus, Jason; Barnes, Jim

    2008-01-01

    A program of research, development, test, and evaluation is planned for the development of Spacecraft Handling Qualities guidelines. In this first experiment, the effects of Reaction Control System design characteristics and rotational control laws were evaluated during simulated proximity operations and docking. Also, the influence of piloting demands resulting from varying closure rates was assessed. The pilot-in-the-loop simulation results showed that significantly different spacecraft handling qualities result from the design of the Reaction Control System. In particular, cross-coupling between translational and rotational motions significantly affected handling qualities as reflected by Cooper-Harper pilot ratings and pilot workload, as reflected by Task-Load Index ratings. This influence is masked but only slightly by the rotational control system mode. While rotational control augmentation using Rate Command Attitude Hold can reduce the workload (principally, physical workload) created by cross-coupling, the handling qualities are not significantly improved. The attitude and rate deadbands of the RCAH introduced significant mental workload and control compensation to evaluate when deadband firings would occur, assess their impact on docking performance, and apply control inputs to mitigate that impact.

  1. The association between higher body mass index and poor school performance in high school students.

    PubMed

    Tonetti, L; Fabbri, M; Filardi, M; Martoni, M; Natale, V

    2016-12-01

    This study aimed to examine the association between body mass index (BMI) and school performance in high school students by controlling for relevant mediators such as sleep quality, sleep duration and socioeconomic status. Thirty-seven high school students (mean age: 18.16 ± 0.44 years) attending the same school type, i.e. 'liceo scientifico' (science-based high school), were enrolled. Students' self-reported weight and height were used to calculate BMI. Participants wore an actigraph to objectively assess the quality and duration of sleep. School performance was assessed through the actual grade obtained at the final school-leaving exam, in which higher grades indicate higher performance. BMI, get-up time, mean motor activity, wake after sleep onset and number of awakenings were negatively correlated with the grade, while sleep efficiency was positively correlated. When performing a multiple regression analysis, BMI proved the only significant (negative) predictor of grade. When controlling for sleep quality, sleep duration and socioeconomic status, a higher BMI is associated with a poorer school performance in high school students. © 2015 World Obesity Federation.

  2. Characterization and effectiveness of pay-for-performance in ophthalmology: a systematic review.

    PubMed

    Herbst, Tim; Emmert, Martin

    2017-06-05

    To identify, characterize and compare existing pay-for-performance approaches and their impact on the quality of care and efficiency in ophthalmology. A systematic evidence-based review was conducted. English, French and German written literature published between 2000 and 2015 were searched in the following databases: Medline (via PubMed), NCBI web site, Scopus, Web of Knowledge, Econlit and the Cochrane Library. Empirical as well as descriptive articles were included. Controlled clinical trials, meta-analyses, randomized controlled studies as well as observational studies were included as empirical articles. Systematic characterization of identified pay-for-performance approaches (P4P approaches) was conducted according to the "Model for Implementing and Monitoring Incentives for Quality" (MIMIQ). Methodological quality of empirical articles was assessed according to the Critical Appraisal Skills Programme (CASP) checklists. Overall, 13 relevant articles were included. Eleven articles were descriptive and two articles included empirical analyses. Based on these articles, four different pay-for-performance approaches implemented in the United States were identified. With regard to quality and incentive elements, systematic comparison showed numerous differences between P4P approaches. Empirical studies showed isolated cost or quality effects, while a simultaneous examination of these effects was missing. Research results show that experiences with pay-for-performance approaches in ophthalmology are limited. Identified approaches differ with regard to quality and incentive elements restricting comparability. Two empirical studies are insufficient to draw strong conclusions about the effectiveness and efficiency of these approaches.

  3. The impact of translucent fabric shades and control strategies on energy savings and visual quality

    NASA Astrophysics Data System (ADS)

    Wankanapon, Pimonmart

    Translucent fabric shades provide opportunities for building occupants to control sunlight penetration for heat reduction, thermal comfort, and visual quality. Regulating shades affects building energy and can potentially reduce the size of mechanical cooling systems. Shades are not normally included in energy model studies during the design process, even though shades potential impact energy use. This is because the occupants normally leave shades closed a large fraction of the time, but models are generally performed with no shades. Automatic shade control is now available, so it is necessary to understand the impact of shades on visual quality and their energy saving potential in order to optimize their overall performance. There are very limited studies that have address shades and their integrated performance on energy consumption and visual quality. Most of these do not reflected modern shade types and their application. The goals of this study are: First, to determine the impact of shades on total, heating, cooling and lighting energy savings with different design and operation parameters. Second, to study and develop different automatic shade control strategies to promote and optimize energy savings and visual quality. A simulation-based approach using EnergyPlus in a parametric study provide better understanding energy savings under different shade conditions. The parametric runs addressed various building parameters such as geometry, orientation, site climate, glazing/shade properties, and shade control strategies with integrated lighting control. The impact of shades was determined for total building and space heating, cooling and lighting energy savings. The effect of shades on visual quality was studied using EnergyPlus, AGI32 and DAYSIM for several indices such as daylight glare index (DGI), work plane illuminance, luminance ratios and view. Different shade control strategies and integrated lighting control were considered with two translucent fabric shade colors. The results clearly show the benefit of automatic shade control strategies with integrated lighting control over a condition when shades are closed all day. The main contributor to the total energy savings is from lighting energy savings, followed by cooling energy savings. Shades provide greater benefit in a hot climate and in a moderate climate than in a cold climate. Different control strategies provide savings in the range of 7-35% for annual total space energy with higher savings with light colored shades. Control strategies of shades should be selected and optimized based on climate, orientation, window area, and window/shade properties. High performance glazings, when equipped with shades, show lower energy savings when compared to standard glazings. High transmittance/reflectance shades, such as white shades, perform better than dark shades in most of the cases due to higher lighting energy savings obtained with the automatic electric lighting control and the resulting cooling energy savings from rejection of some solar energy and a reduction in the heat from lights. A South orientation showed the least benefit of automatic control of shades when compare to other orientations due to the large fraction of time shades are required to provide visual comfort. Under automatic shade control, energy savings are higher the more often the shades can be raised. The different automatic control strategies present tradeoffs between energy savings and comfort. With regard to visual quality, daylight quality assessments on view, glare, luminance ratios, and UDI can be used to assess shade control strategies. Automatic shade control can increase the number of view hours while controlling sunlight penetration. With automatic shade control, more daylight hours can be provided within the beneficial range of 100-2000 lux compared to shades that are closed all day. For a person facing the window, discomfort glare is likely to increase the more often the shades are raised. Keeping the shades down ensures an acceptable glare condition, but limits energy savings. Luminance ratios are another metric that can be used to assess shade performance. With white shades, the luminance ratios between the task and proximate surfaces are improved. Dark shades help improve the luminance ratios between the task and distant surfaces. When the shades are left open, even with no direct sunlight in the space, task to window luminance ratios will often exceed 1:10.

  4. Distributed sensor architecture for intelligent control that supports quality of control and quality of service.

    PubMed

    Poza-Lujan, Jose-Luis; Posadas-Yagüe, Juan-Luis; Simó-Ten, José-Enrique; Simarro, Raúl; Benet, Ginés

    2015-02-25

    This paper is part of a study of intelligent architectures for distributed control and communications systems. The study focuses on optimizing control systems by evaluating the performance of middleware through quality of service (QoS) parameters and the optimization of control using Quality of Control (QoC) parameters. The main aim of this work is to study, design, develop, and evaluate a distributed control architecture based on the Data-Distribution Service for Real-Time Systems (DDS) communication standard as proposed by the Object Management Group (OMG). As a result of the study, an architecture called Frame-Sensor-Adapter to Control (FSACtrl) has been developed. FSACtrl provides a model to implement an intelligent distributed Event-Based Control (EBC) system with support to measure QoS and QoC parameters. The novelty consists of using, simultaneously, the measured QoS and QoC parameters to make decisions about the control action with a new method called Event Based Quality Integral Cycle. To validate the architecture, the first five Braitenberg vehicles have been implemented using the FSACtrl architecture. The experimental outcomes, demonstrate the convenience of using jointly QoS and QoC parameters in distributed control systems.

  5. Distributed Sensor Architecture for Intelligent Control that Supports Quality of Control and Quality of Service

    PubMed Central

    Poza-Lujan, Jose-Luis; Posadas-Yagüe, Juan-Luis; Simó-Ten, José-Enrique; Simarro, Raúl; Benet, Ginés

    2015-01-01

    This paper is part of a study of intelligent architectures for distributed control and communications systems. The study focuses on optimizing control systems by evaluating the performance of middleware through quality of service (QoS) parameters and the optimization of control using Quality of Control (QoC) parameters. The main aim of this work is to study, design, develop, and evaluate a distributed control architecture based on the Data-Distribution Service for Real-Time Systems (DDS) communication standard as proposed by the Object Management Group (OMG). As a result of the study, an architecture called Frame-Sensor-Adapter to Control (FSACtrl) has been developed. FSACtrl provides a model to implement an intelligent distributed Event-Based Control (EBC) system with support to measure QoS and QoC parameters. The novelty consists of using, simultaneously, the measured QoS and QoC parameters to make decisions about the control action with a new method called Event Based Quality Integral Cycle. To validate the architecture, the first five Braitenberg vehicles have been implemented using the FSACtrl architecture. The experimental outcomes, demonstrate the convenience of using jointly QoS and QoC parameters in distributed control systems. PMID:25723145

  6. Kodak Skills Enhancement Program Curriculum: Math for Manufacturing and Quality Control. Report No. AEP-93-01.

    ERIC Educational Resources Information Center

    Beaudin, Bart P.; And Others

    This teacher's guide is intended for use in helping Kodak Corporation employees develop the basic mathematics skills required to perform the manufacturing and quality control tasks expected of them. The following topics are covered in the first five modules: the four basic functions (adding, subtracting, multiplying, and dividing), calculations…

  7. Can current analytical quality performance of UK clinical laboratories support evidence-based guidelines for diabetes and ischaemic heart disease?--A pilot study and a proposal.

    PubMed

    Jassam, Nuthar; Yundt-Pacheco, John; Jansen, Rob; Thomas, Annette; Barth, Julian H

    2013-08-01

    The implementation of national and international guidelines is beginning to standardise clinical practice. However, since many guidelines have decision limits based on laboratory tests, there is an urgent need to ensure that different laboratories obtain the same analytical result on any sample. A scientifically-based quality control process will be a pre-requisite to provide this level of analytical performance which will support evidence-based guidelines and movement of patients across boundaries while maintaining standardised outcomes. We discuss the finding of a pilot study performed to assess UK clinical laboratories readiness to work to a higher grade quality specifications such as biological variation-based quality specifications. Internal quality control (IQC) data for HbA1c, glucose, creatinine, cholesterol and high density lipoprotein (HDL)-cholesterol were collected from UK laboratories participating in the Bio-Rad Unity QC programme. The median of the coefficient of variation (CV%) of the participating laboratories was evaluated against the CV% based on biological variation. Except creatinine, the other four analytes had a variable degree of compliance with the biological variation-based quality specifications. More than 75% of the laboratories met the biological variation-based quality specifications for glucose, cholesterol and HDL-cholesterol. Slightly over 50% of the laboratories met the analytical goal for HBA1c. Only one analyte (cholesterol) had a performance achieving the higher quality specifications consistent with 5σ. Our data from IQC do not consistently demonstrate that the results from clinical laboratories meet evidence-based quality specifications. Therefore, we propose that a graded scale of quality specifications may be needed at this stage.

  8. 40 CFR 35.588 - Award limitations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Tribe or Intertribal Consortium meets the applicable quality assurance and quality control requirements... Intertribal Consortium agrees to include a discussion of how the work performed under section 106 addressed water quality problems on Tribal lands in the annual report required under § 35.515(d). (5) After an...

  9. 40 CFR 35.588 - Award limitations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Tribe or Intertribal Consortium meets the applicable quality assurance and quality control requirements... Intertribal Consortium agrees to include a discussion of how the work performed under section 106 addressed water quality problems on Tribal lands in the annual report required under § 35.515(d). (5) After an...

  10. [Implementation of quality standard UNE-EN ISO/IEC 17043 in the External Quality Control Program of the Spanish Society of Infectious Diseases and Clinical Microbiology].

    PubMed

    Poveda Gabaldón, Marta; Ovies, María Rosario; Orta Mira, Nieves; Serrano, M del Remedio Guna; Avila, Javier; Giménez, Alicia; Cardona, Concepción Gimeno

    2011-12-01

    The quality standard "UNE-EN-ISO 17043: 2010. Conformity assessment. General requirements for proficiency testing" applies to centers that organize intercomparisons in all areas. In the case of clinical microbiology laboratories, these intercomparisons must meet the management and technical standards required to achieve maximum quality in the performance of microbiological analysis and the preparation of test items (sample, product, data or other information used in the proficiency test) to enable them to be accredited. Once accredited, these laboratories can operate as a tool for quality control laboratories and competency assessment. In Spain, accreditation is granted by the Spanish Accreditation Body [Entidad Nacional de Acreditación (ENAC)]. The objective of this review is to explain how to apply the requirements of the standard to laboratories providing intercomparisons in the field of clinical microbiology (the organization responsible for all the tasks related to the development and operation of a proficiency testing program). This requires defining the scope and specifying the technical requirements (personnel management, control of equipment, facilities and environment, the design of the proficiency testing and data analysis for performance evaluation, communication with participants and confidentiality) and management requirements (document control, purchasing control, monitoring of complaints / claims, non-compliance, internal audits and management reviews). Copyright © 2011 Elsevier España S.L. All rights reserved.

  11. Quality Assurance of RNA Expression Profiling in Clinical Laboratories

    PubMed Central

    Tang, Weihua; Hu, Zhiyuan; Muallem, Hind; Gulley, Margaret L.

    2012-01-01

    RNA expression profiles are increasingly used to diagnose and classify disease, based on expression patterns of as many as several thousand RNAs. To ensure quality of expression profiling services in clinical settings, a standard operating procedure incorporates multiple quality indicators and controls, beginning with preanalytic specimen preparation and proceeding thorough analysis, interpretation, and reporting. Before testing, histopathological examination of each cellular specimen, along with optional cell enrichment procedures, ensures adequacy of the input tissue. Other tactics include endogenous controls to evaluate adequacy of RNA and exogenous or spiked controls to evaluate run- and patient-specific performance of the test system, respectively. Unique aspects of quality assurance for array-based tests include controls for the pertinent outcome signatures that often supersede controls for each individual analyte, built-in redundancy for critical analytes or biochemical pathways, and software-supported scrutiny of abundant data by a laboratory physician who interprets the findings in a manner facilitating appropriate medical intervention. Access to high-quality reagents, instruments, and software from commercial sources promotes standardization and adoption in clinical settings, once an assay is vetted in validation studies as being analytically sound and clinically useful. Careful attention to the well-honed principles of laboratory medicine, along with guidance from government and professional groups on strategies to preserve RNA and manage large data sets, promotes clinical-grade assay performance. PMID:22020152

  12. Image quality prediction - An aid to the Viking lander imaging investigation on Mars

    NASA Technical Reports Server (NTRS)

    Huck, F. O.; Wall, S. D.

    1976-01-01

    Image quality criteria and image quality predictions are formulated for the multispectral panoramic cameras carried by the Viking Mars landers. Image quality predictions are based on expected camera performance, Mars surface radiance, and lighting and viewing geometry (fields of view, Mars lander shadows, solar day-night alternation), and are needed in diagnosis of camera performance, in arriving at a preflight imaging strategy, and revision of that strategy should the need arise. Landing considerations, camera control instructions, camera control logic, aspects of the imaging process (spectral response, spatial response, sensitivity), and likely problems are discussed. Major concerns include: degradation of camera response by isotope radiation, uncertainties in lighting and viewing geometry and in landing site local topography, contamination of camera window by dust abrasion, and initial errors in assigning camera dynamic ranges (gains and offsets).

  13. [Coronary artery bypass surgery: methods of performance monitoring and quality control].

    PubMed

    Albert, A; Sergeant, P; Ennker, J

    2009-10-01

    The strength of coronary bypass operations depends on the preservation of their benefits regarding freedom of symptoms, quality of life and survival, over decades. Significant variability of the results of an operative intervention according to the hospital or the operating surgeon is considered a weakness in the procedure. The external quality insurance tries to reach a transparent service providing market through hospital ranking comparability. Widely available information and competition will promote the improvement of the whole quality. The structured dialog acts as a control instrument for the BQS (Federal Quality Insurance). It is launched in case of deviations from the standard references or statistically significant differences between the results of the operations in any hospital and the average notational results. In comparison to the external control the hospital internal control has greater ability to reach a medically useful statement regarding the results of the treatment and to correct the mistakes in time. An online information portal based on a departmental databank (DataWarehouse, DataMart) is an attractive solution for the physician in order to get transparently and timely informed about the variability in the performance.The individual surgeon significantly influences the short- and long-term treatment results. Accordingly, selection, targeted training and performance measurements are necessary.Strict risk management and failure analysis of individual cases are included in the methods of internal quality control aiming to identify and correct the inadequacies in the system and the course of treatment. According to the international as well as our own experience, at least 30% of the mortalities after bypass operations are avoidable. A functioning quality control is especially important in minimally invasive interventions because they are often technically more demanding in comparison to the conventional procedures. In the field of OPCAB surgery, the special advantages of the procedure can be utilised to reach a nearly complete avoidance of postoperative stroke through combining the procedure with aorta no-touch technique. The long-term success of the bypass operation depends on the type of bypass material in additions to many other factors. Both internal mammary arteries are considered the most durable.Using an operation preparation check contributes to the operative success.

  14. [Effects of aerobic exercise program and relaxation techniques on anxiety, quality of sleep, depression, and quality of life in patients with fibromyalgia: a randomized controlled trial].

    PubMed

    Arcos-Carmona, Isabel María; Castro-Sánchez, Adelaida María; Matarán-Peñarrocha, Guillermo Adolfo; Gutiérrez-Rubio, Ana Belén; Ramos-González, Elena; Moreno-Lorenzo, Carmen

    2011-10-08

    Fibromyalgia is considered as a combination of physical, psychological and social disabilities. The purpose of the present study was to determine the benefits of aerobic exercise program and progressive relaxation techniques on anxiety, quality of sleep, depression and quality of life in patients with fibromyalgia. An experimental study was performed with a placebo control group. Fifty-six fibromyalgia patients were randomly assigned to intervention (aerobic exercises+progressive relaxation techniques) and placebo (sham treatment with disconnected magnet therapy device) groups. Outcome measures were anxiety (STAI- State Trait Anxiety Inventory), quality of sleep (Pittsburgh sleep quality index), depression (Beck depression inventory) and quality of life (questionnaire SF-36). Measures were performed at baseline and after 10-weeks treatment. After 10 weeks of treatment, the intervention group showed significant reduction (p<0.05) in sleep duration, trait anxiety and quality of life. The combination of aerobic exercise program and progressive relaxation techniques contribute to improve night rest, trait anxiety and quality of life in patients with fibromyalgia. Copyright © 2010 Elsevier España, S.L. All rights reserved.

  15. Video on Diet Before Outpatient Colonoscopy Does Not Improve Quality of Bowel Preparation: A Prospective, Randomized, Controlled Trial.

    PubMed

    Rice, Sean C; Higginbotham, Tina; Dean, Melanie J; Slaughter, James C; Yachimski, Patrick S; Obstein, Keith L

    2016-11-01

    Successful outpatient colonoscopy (CLS) depends on many factors including the quality of a patient's bowel preparation. Although education on consumption of the pre-CLS purgative can improve bowel preparation quality, no study has evaluated dietary education alone. We have created an educational video on pre-CLS dietary instructions to determine whether dietary education would improve outpatient bowel preparation quality. A prospective randomized, blinded, controlled study of patients undergoing outpatient CLS was performed. All patients received a 4 l polyethylene glycol-based split-dose bowel preparation and standard institutional pre-procedure instructions. Patients were then randomly assigned to an intervention arm or to a no intervention arm. A 4-min educational video detailing clear liquid diet restriction was made available to patients in the intervention arm, whereas those randomized to no intervention did not have access to the video. Patients randomized to the video were provided with the YouTube video link 48-72 h before CLS. An attending endoscopist blinded to randomization performed the CLS. Bowel preparation quality was scored using the Boston Bowel Preparation Scale (BBPS). Adequate preparation was defined as a BBPS total score of ≥6 with all segment scores ≥2. Wilcoxon rank-sum and Pearson's χ 2 -tests were performed to assess differences between groups. Ninety-two patients were randomized (video: n=42; control: n=50) with 47 total video views being tallied. There were no demographic differences between groups. There was no statistically significant difference in adequate preparation between groups (video=74%; control=68%; P=0.54). The availability of a supplementary patient educational video on clear liquid diet alone was insufficient to improve bowel preparation quality when compared with standard pre-procedure instruction at our institution.

  16. Quality assurance in road traffic analyses in Switzerland.

    PubMed

    Briellmann, Thomas A; Sigrist, Thomas; Augsburger, Marc; Favrat, Bernard; Oestreich, Andrea; Deom, André

    2010-05-20

    Swiss laboratories performing toxicological road traffic analyses have been authorized for many years by the Swiss Federal Roads Office (FEDRO). In 2003 FEDRO signed a contract with the Swiss Society of Legal Medicine (SSLM) to organize the complete quality management concerning road traffic analyses. For this purpose a multidisciplinary working group was established under the name of "road traffic commission (RTC)". RTC has to organize external quality control, to interpret the results of these controls, to perform audits in the laboratories and to report all results to FEDRO. Furthermore the working group can be mandated for special tasks by FEDRO. As an independent organization the Swiss Center for Quality Control (CSCQ) in Geneva manages the external quality controls in the laboratory over the past years. All tested drugs and psychoactive substances are listed in a federal instruction. The so-called 'zero tolerance substances' (THC, morphine, cocaine, amphetamine, methamphetamine, MDMA and MDEA) and their metabolites have to be tested once a year, all other substances (benzodiazepines, zolpidem, phenobarbital, etc.) periodically. Results over the last years show that all laboratories are generally within the confidence interval of +/-30% of the mean value. In cases of non-conformities measures have to be taken immediately and reported to the working group. External audits are performed triennially but accredited laboratories can combine this audit with the approval of the Swiss Accreditation Service (SAS). During the audits a special checklist filled in by the laboratory director is assessed. Non-conformities have to be corrected. During the process of establishing a new legislation, RTC had an opportunity of advising FEDRO. In collaboration with FEDRO, RTC and hence SSLM can work actively on improving of quality assurance in road traffic toxicological analyses, and has an opportunity to bring its professional requests to the federal authorities.

  17. Quality of pancreatic transplant program assessment using a risk-adjusted cumulative sum chart: experience from a single, small center.

    PubMed

    Grochowiecki, T; Jakimowicz, T; Grabowska-Derlatka, L; Szmidt, J

    2014-10-01

    The high rate of complication after pancreas transplantation not only had an impact on recipient quality of life and survival but also had significant financial implications. Thus, monitoring transplant center performance was crucial to indentifying changes in clinical practice that result in quality deterioration. To evaluate retrospectively the quality of the single, small pancreatic transplant program and to establish prospective monitoring of the center using risk-adjusted cumulative sum (CUSUM). From 1988 to 2014, 119 simultaneous pancreas and the kidney transplantations (SPKTx) were performed. The program was divided into 3 eras, based on surgical technique and immunosuppression. Analyses of the 15 fatal outcomes due to complication from pancreatic graft were performed. The risk model was developed using multivariable logistic regression analysis based on retrospective data of 112 SPKTx recipients. The risk-adjusted 1-sided CUSUM chart was plotted for retrospective and prospective events. The upper control limit was set to 2. There were 2 main causes of death: multiorgan failure (73.3%; 11/15) and septic hemorrhage (26.7%; 4/15). Quality analysis using the CUSUM chart revealed that the process was not homogeneous; however, no significant signal of program deterioration was obtained and the performance of the whole program was within the settled control limit. For a single pancreatic transplant center. The risk-adjusted CUSUM chart was a useful tool for quality program assessment. It could support decision making during traditional surgical morbidity and mortality conferences. For small transplant centers, increasing the sensitivity of the CUSUM method by lowering the upper control limit should be considered. However, an individual assessment approach of the for particular centers is recommended.

  18. Manufacturing Execution Systems: Examples of Performance Indicator and Operational Robustness Tools.

    PubMed

    Gendre, Yannick; Waridel, Gérard; Guyon, Myrtille; Demuth, Jean-François; Guelpa, Hervé; Humbert, Thierry

    Manufacturing Execution Systems (MES) are computerized systems used to measure production performance in terms of productivity, yield, and quality. In the first part, performance indicator and overall equipment effectiveness (OEE), process robustness tools and statistical process control are described. The second part details some tools to help process robustness and control by operators by preventing deviations from target control charts. MES was developed by Syngenta together with CIMO for automation.

  19. Significant improvement of the quality of bystander first aid using an expert system with a mobile multimedia device.

    PubMed

    Ertl, Lorenz; Christ, Frank

    2007-08-01

    Better quality bystander first-aid could improve outcome rates for emergency victims significantly. In this case-control study, we hypothesised that expert knowledge presented step-by-step to untrained helpers using a personal digital assistant (PDA), would improve the quality of bystanders basic life support. We confronted 101 lay-helpers with two standard emergency situations. (1) An unconscious trauma victim with severe bleeding. (2) Cardiopulmonary resuscitation (CPR). Performance was assessed using an Objective Structured Clinical Examination (OSCE). One group was supported by a PDA providing visual and audio instructions, whereas the control group acted only with their current knowledge. The expert system was programmed in HTML-code and displayed on the PDA's Internet browser. The maximum score obtainable was 24 points corresponding to optimal treatment. The control group without the PDA reached 14.8+/-3.5 (mean value+/-standard deviation), whereas the PDA supported group scored significantly higher (21.9+/-2.7, p<0.01). The difference in performance was measurable in all criteria tested and particularly notable in the items: placing in recovery position, airway management and quality of CPR. The PDA based expert system increased the performance of untrained helpers supplying emergency care significantly. Since Internet compatible mobile devices have become widely available, a significant quality improvement in bystander first-aid seems possible.

  20. Metal-backed versus all-polyethylene tibial components in primary total knee arthroplasty

    PubMed Central

    2011-01-01

    Background and purpose The choice of either all-polyethylene (AP) tibial components or metal-backed (MB) tibial components in total knee arthroplasty (TKA) remains controversial. We therefore performed a meta-analysis and systematic review of randomized controlled trials that have evaluated MB and AP tibial components in primary TKA. Methods The search strategy included a computerized literature search (Medline, EMBASE, Scopus, and the Cochrane Central Register of Controlled Trials) and a manual search of major orthopedic journals. A meta-analysis and systematic review of randomized or quasi-randomized trials that compared the performance of tibial components in primary TKA was performed using a fixed or random effects model. We assessed the methodological quality of studies using Detsky quality scale. Results 9 randomized controlled trials (RCTs) published between 2000 and 2009 met the inclusion quality standards for the systematic review. The mean standardized Detsky score was 14 (SD 3). We found that the frequency of radiolucent lines in the MB group was significantly higher than that in the AP group. There were no statistically significant differences between the MB and AP tibial components regarding component positioning, knee score, knee range of motion, quality of life, and postoperative complications. Interpretation Based on evidence obtained from this study, the AP tibial component was comparable with or better than the MB tibial component in TKA. However, high-quality RCTs are required to validate the results. PMID:21895503

  1. The Individualized Quality Control Plan - Coming Soon to Clinical Microbiology Laboratories Everywhere!

    PubMed

    Anderson, Nancy

    2015-11-15

    As of January 1, 2016, microbiology laboratories can choose to adopt a new quality control option, the Individualized Quality Control Plan (IQCP), under the Clinical Laboratory Improvement Amendments of 1988 (CLIA). This voluntary approach increases flexibility for meeting regulatory requirements and provides laboratories the opportunity to customize QC for their testing in their unique environments and by their testing personnel. IQCP is an all-inclusive approach to quality based on risk management to address potential errors in the total testing process. It includes three main steps, (1) performing a risk assessment, (2) developing a QC plan, and (3) monitoring the plan through quality assessment. Resources are available from the Centers for Medicare & Medicaid Services, Centers for Disease Control and Prevention, American Society for Microbiology, Clinical and Laboratory Standards Institute, and accrediting organizations, such as the College of American Pathologists and Joint Commission, to assist microbiology laboratories implementing IQCP.

  2. Impact of dose calibrators quality control programme in Argentina

    NASA Astrophysics Data System (ADS)

    Furnari, J. C.; de Cabrejas, M. L.; del C. Rotta, M.; Iglicki, F. A.; Milá, M. I.; Magnavacca, C.; Dima, J. C.; Rodríguez Pasqués, R. H.

    1992-02-01

    The national Quality Control (QC) programme for radionuclide calibrators started 12 years ago. Accuracy and the implementation of a QC programme were evaluated over all these years at 95 nuclear medicine laboratories where dose calibrators were in use. During all that time, the Metrology Group of CNEA has distributed 137Cs sealed sources to check stability and has been performing periodic "checking rounds" and postal surveys using unknown samples (external quality control). An account of the results of both methods is presented. At present, more of 65% of the dose calibrators measure activities with an error less than 10%.

  3. Computer graphics for quality control in the INAA of geological samples

    USGS Publications Warehouse

    Grossman, J.N.; Baedecker, P.A.

    1987-01-01

    A data reduction system for the routine instrumental activation analysis of samples is described, with particular emphasis on interactive graphics capabilities for evaluating analytical quality. Graphics procedures have been developed to interactively control the analysis of selected photopeaks during spectral analysis, and to evaluate detector performance during a given counting cycle. Graphics algorithms are also used to compare the data on reference samples with accepted values, to prepare quality control charts to evaluate long term precision and to search for systematic variations in data on reference samples as a function of time. ?? 1987 Akade??miai Kiado??.

  4. Measuring management's perspective of data quality in Pakistan's Tuberculosis control programme: a test-based approach to identify data quality dimensions.

    PubMed

    Ali, Syed Mustafa; Anjum, Naveed; Kamel Boulos, Maged N; Ishaq, Muhammad; Aamir, Javariya; Haider, Ghulam Rasool

    2018-01-16

    Data quality is core theme of programme's performance assessment and many organizations do not have any data quality improvement strategy, wherein data quality dimensions and data quality assessment framework are important constituents. As there is limited published research about the data quality specifics that are relevant to the context of Pakistan's Tuberculosis control programme, this study aims at identifying the applicable data quality dimensions by using the 'fitness-for-purpose' perspective. Forty-two respondents pooled a total of 473 years of professional experience, out of which 223 years (47%) were in TB control related programmes. Based on the responses against 11 practical cases, adopted from the routine recording and reporting system of Pakistan's TB control programme (real identities of patient were masked), completeness, accuracy, consistency, vagueness, uniqueness and timeliness are the applicable data quality dimensions relevant to the programme's context, i.e. work settings and field of practice. Based on a 'fitness-for-purpose' approach to data quality, this study used a test-based approach to measure management's perspective and identified data quality dimensions pertinent to the programme and country specific requirements. Implementation of a data quality improvement strategy and achieving enhanced data quality would greatly help organizations in promoting data use for informed decision making.

  5. Application of Statistical Quality Control Techniques to Detonator Fabrication: Feasibility Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, J. Frank

    1971-05-20

    A feasibility study was performed on the use of process control techniques which might reduce the need for a duplicate inspection by production inspection and quality control inspection. Two active detonator fabrication programs were selected for the study. Inspection areas accounting for the greatest percentage of total inspection costs were selected by applying "Pareto's Principle of Maldistribution." Data from these areas were then gathered and analyzed by a process capabiltiy study.

  6. Electronic adherence monitoring device performance and patient acceptability: a randomized control trial.

    PubMed

    Chan, Amy Hai Yan; Stewart, Alistair William; Harrison, Jeff; Black, Peter Nigel; Mitchell, Edwin Arthur; Foster, Juliet Michelle

    2017-05-01

    To investigate the performance and patient acceptability of an inhaler electronic monitoring device in a real-world childhood asthma population. Children 6 to 15 years presenting with asthma to the hospital emergency department and prescribed inhaled corticosteroids were included. Participants were randomized to receive a device with reminder features enabled or disabled for use with their preventer. Device quality control tests were conducted. Questionnaires on device acceptability, utility and ergonomics were completed at six months. A total of 1306 quality control tests were conducted; 84% passed pre-issue and 87% return testing. The most common failure reason was actuation under-recording. Acceptability scores were high, with higher scores in the reminder than non-reminder group (median, 5 th -95 th percentile: 4.1, 3.1-5.0 versus 3.7, 2.3-4.8; p < 0.001). Most (>90%) rated the device easy to use. Feedback was positive across five themes: device acceptability, ringtone acceptability, suggestions for improvement, effect on medication use, and effect on asthma control. This study investigates electronic monitoring device performance and acceptability in children using quantitative and qualitative measures. Results indicate satisfactory reliability, although failure rates of 13-16% indicate the importance of quality control. Favorable acceptability ratings support the use of these devices in children.

  7. RoCoMAR: robots' controllable mobility aided routing and relay architecture for mobile sensor networks.

    PubMed

    Le, Duc Van; Oh, Hoon; Yoon, Seokhoon

    2013-07-05

    In a practical deployment, mobile sensor network (MSN) suffers from a low performance due to high node mobility, time-varying wireless channel properties, and obstacles between communicating nodes. In order to tackle the problem of low network performance and provide a desired end-to-end data transfer quality, in this paper we propose a novel ad hoc routing and relaying architecture, namely RoCoMAR (Robots' Controllable Mobility Aided Routing) that uses robotic nodes' controllable mobility. RoCoMAR repeatedly performs link reinforcement process with the objective of maximizing the network throughput, in which the link with the lowest quality on the path is identified and replaced with high quality links by placing a robotic node as a relay at an optimal position. The robotic node resigns as a relay if the objective is achieved or no more gain can be obtained with a new relay. Once placed as a relay, the robotic node performs adaptive link maintenance by adjusting its position according to the movements of regular nodes. The simulation results show that RoCoMAR outperforms existing ad hoc routing protocols for MSN in terms of network throughput and end-to-end delay.

  8. RoCoMAR: Robots' Controllable Mobility Aided Routing and Relay Architecture for Mobile Sensor Networks

    PubMed Central

    Van Le, Duc; Oh, Hoon; Yoon, Seokhoon

    2013-01-01

    In a practical deployment, mobile sensor network (MSN) suffers from a low performance due to high node mobility, time-varying wireless channel properties, and obstacles between communicating nodes. In order to tackle the problem of low network performance and provide a desired end-to-end data transfer quality, in this paper we propose a novel ad hoc routing and relaying architecture, namely RoCoMAR (Robots' Controllable Mobility Aided Routing) that uses robotic nodes' controllable mobility. RoCoMAR repeatedly performs link reinforcement process with the objective of maximizing the network throughput, in which the link with the lowest quality on the path is identified and replaced with high quality links by placing a robotic node as a relay at an optimal position. The robotic node resigns as a relay if the objective is achieved or no more gain can be obtained with a new relay. Once placed as a relay, the robotic node performs adaptive link maintenance by adjusting its position according to the movements of regular nodes. The simulation results show that RoCoMAR outperforms existing ad hoc routing protocols for MSN in terms of network throughput and end-to-end delay. PMID:23881134

  9. Dynamic Evaluation of a Regional Air Quality Model: Assessing the Emissions-Induced Weekly Ozone Cycle

    EPA Science Inventory

    Air quality models are used to predict changes in pollutant concentrations resulting from envisioned emission control policies. Recognizing the need to assess the credibility of air quality models in a policy-relevant context, we perform a dynamic evaluation of the community Mult...

  10. Verification and quality control of routine hematology analyzers.

    PubMed

    Vis, J Y; Huisman, A

    2016-05-01

    Verification of hematology analyzers (automated blood cell counters) is mandatory before new hematology analyzers may be used in routine clinical care. The verification process consists of several items which comprise among others: precision, accuracy, comparability, carryover, background and linearity throughout the expected range of results. Yet, which standard should be met or which verification limit be used is at the discretion of the laboratory specialist. This paper offers practical guidance on verification and quality control of automated hematology analyzers and provides an expert opinion on the performance standard that should be met by the contemporary generation of hematology analyzers. Therefore (i) the state-of-the-art performance of hematology analyzers for complete blood count parameters is summarized, (ii) considerations, challenges, and pitfalls concerning the development of a verification plan are discussed, (iii) guidance is given regarding the establishment of reference intervals, and (iv) different methods on quality control of hematology analyzers are reviewed. © 2016 John Wiley & Sons Ltd.

  11. Adult survivors of childhood acute lymphoblastic leukaemia with GH deficiency have normal self-rated quality of life but impaired neuropsychological performance 20 years after cranial irradiation.

    PubMed

    Link, Katarina; Moëll, Christian; Osterberg, Kai; Persson, Roger; Ørbaek, Palle; Garwicz, Stanislaw; Cavallin-Ståhl, Eva; Erfurth, Eva Marie

    2006-11-01

    Cranial radiotherapy (CRT) was, until recently, important for achieving long-term survival in acute lymphoblastic leukaemia (ALL). Because survival rates have improved markedly, the long-term complications, such as GH deficiency (GHD) and neuropsychological impairment, have become increasingly important. The level of self-reported quality of life and neuropsychological functioning was investigated in 44 adults (21 women) with a median age of 25 years who had been treated for childhood onset (CO) ALL with CRT (median 24 Gy). Comparison was made with matched population controls. A subset of patients with GHD was evaluated for neuropsychological functioning after 1 year of GH treatment. Compared to controls, the patients had significantly lower performance in neuropsychological tests. Early age at treatment had a significant negative impact on neuropsychological performance in adulthood. No relationship was found between dose of CRT, time since treatment of ALL or gender and neuropsychological performance. Compared to controls, the patients did not show a poor quality of life or a lowered availability of social interactions or social networks; however, significantly more patients were living alone or with their parents. After GH testing, the patients were all considered GH deficient or insufficient, but no relationship was observed between stimulated peak GH secretion and neuropsychological performance. Treatment with GH for 1 year in a subgroup of the patients did not improve their neuropsychological performance. This study showed that adults treated with CRT for CO ALL had GHD and significantly impaired neuropsychological performance, although self-reported quality of life was not affected. The effect of GH treatment in this patient group has to be further elucidated.

  12. [Statistical process control applied to intensity modulated radiotherapy pretreatment controls with portal dosimetry].

    PubMed

    Villani, N; Gérard, K; Marchesi, V; Huger, S; François, P; Noël, A

    2010-06-01

    The first purpose of this study was to illustrate the contribution of statistical process control for a better security in intensity modulated radiotherapy (IMRT) treatments. This improvement is possible by controlling the dose delivery process, characterized by pretreatment quality control results. So, it is necessary to put under control portal dosimetry measurements (currently, the ionisation chamber measurements were already monitored by statistical process control thanks to statistical process control tools). The second objective was to state whether it is possible to substitute ionisation chamber with portal dosimetry in order to optimize time devoted to pretreatment quality control. At Alexis-Vautrin center, pretreatment quality controls in IMRT for prostate and head and neck treatments were performed for each beam of each patient. These controls were made with an ionisation chamber, which is the reference detector for the absolute dose measurement, and with portal dosimetry for the verification of dose distribution. Statistical process control is a statistical analysis method, coming from industry, used to control and improve the studied process quality. It uses graphic tools as control maps to follow-up process, warning the operator in case of failure, and quantitative tools to evaluate the process toward its ability to respect guidelines: this is the capability study. The study was performed on 450 head and neck beams and on 100 prostate beams. Control charts, showing drifts, both slow and weak, and also both strong and fast, of mean and standard deviation have been established and have shown special cause introduced (manual shift of the leaf gap of the multileaf collimator). Correlation between dose measured at one point, given with the EPID and the ionisation chamber has been evaluated at more than 97% and disagreement cases between the two measurements were identified. The study allowed to demonstrate the feasibility to reduce the time devoted to pretreatment controls, by substituting the ionisation chamber's measurements with those performed with EPID, and also that a statistical process control monitoring of data brought security guarantee. 2010 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  13. Operational CryoSat Product Quality Assessment

    NASA Astrophysics Data System (ADS)

    Mannan, Rubinder; Webb, Erica; Hall, Amanda; Bouzinac, Catherine

    2013-12-01

    The performance and quality of the CryoSat data products are routinely assessed by the Instrument Data quality Evaluation and Analysis Service (IDEAS). This information is then conveyed to the scientific and user community in order to allow them to utilise CryoSat data with confidence. This paper presents details of the Quality Control (QC) activities performed for CryoSat products under the IDEAS contract. Details of the different QC procedures and tools deployed by IDEAS to assess the quality of operational data are presented. The latest updates to the Instrument Processing Facility (IPF) for the Fast Delivery Marine (FDM) products and the future update to Baseline-C are discussed.

  14. Evaluation of Flying Qualities and Guidance Displays for an Advanced Tilt-Wing STOL Transport Aircraft in Final Approach and Landing

    NASA Technical Reports Server (NTRS)

    Frost, Chad R.; Franklin, James A.; Hardy, Gordon H.

    2002-01-01

    A piloted simulation was performed on the Vertical Motion Simulator at NASA Ames Research Center to evaluate flying qualities of a tilt-wing Short Take-Off and Landing (STOL) transport aircraft during final approach and landing. The experiment was conducted to assess the design s handling qualities, and to evaluate the use of flightpath-centered guidance for the precision approach and landing tasks required to perform STOL operations in instrument meteorological conditions, turbulence, and wind. Pilots rated the handling qualities to be satisfactory for all operations evaluated except those encountering extreme crosswinds and severe windshear; even in these difficult meteorological conditions, adequate handling qualities were maintained. The advanced flight control laws and guidance displays provided consistent performance and precision landings.

  15. Climate uniformity: its influence on team communication quality, task conflict, and team performance.

    PubMed

    González-Romá, Vicente; Hernández, Ana

    2014-11-01

    We investigated whether climate uniformity (the pattern of climate perceptions of organizational support within the team) is related to task conflict, team communication quality, and team performance. We used a sample composed of 141 bank branches and collected data at 3 time points. The results obtained showed that, after controlling for aggregate team climate, climate strength, and their interaction, a type of nonuniform climate pattern (weak dissimilarity) was directly related to task conflict and team communication quality. Teams with weak dissimilarity nonuniform patterns tended to show higher levels of task conflict and lower levels of team communication quality than teams with uniform climate patterns. The relationship between weak dissimilarity patterns and team performance was fully mediated by team communication quality. (PsycINFO Database Record (c) 2014 APA, all rights reserved).

  16. Measuring, managing and maximizing refinery performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bascur, O.A.; Kennedy, J.P.

    1996-01-01

    Implementing continuous quality improvement is a confluence of total quality management, people empowerment, performance indicators and information engineering. Supporting information technologies allow a refiner to narrow the gap between management objectives and the process control level. Dynamic performance monitoring benefits come from production cost savings, improved communications and enhanced decision making. A refinery workgroup information flow model helps automate continuous improvement of processes, performance and the organization. The paper discusses the rethinking of refinery operations, dynamic performance monitoring, continuous process improvement, the knowledge coordinator and repository manager, an integrated plant operations workflow, and successful implementation.

  17. Multi-Criteria Decision Making Approaches for Quality Control of Genome-Wide Association Studies

    PubMed Central

    Malovini, Alberto; Rognoni, Carla; Puca, Annibale; Bellazzi, Riccardo

    2009-01-01

    Experimental errors in the genotyping phases of a Genome-Wide Association Study (GWAS) can lead to false positive findings and to spurious associations. An appropriate quality control phase could minimize the effects of this kind of errors. Several filtering criteria can be used to perform quality control. Currently, no formal methods have been proposed for taking into account at the same time these criteria and the experimenter’s preferences. In this paper we propose two strategies for setting appropriate genotyping rate thresholds for GWAS quality control. These two approaches are based on the Multi-Criteria Decision Making theory. We have applied our method on a real dataset composed by 734 individuals affected by Arterial Hypertension (AH) and 486 nonagenarians without history of AH. The proposed strategies appear to deal with GWAS quality control in a sound way, as they lead to rationalize and make explicit the experimenter’s choices thus providing more reproducible results. PMID:21347174

  18. 10 CFR 74.59 - Quality assurance and accounting requirements.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... analyses and evaluations of the design, installation, preoperational tests, calibration, and operation of... performed at a pre-determined frequency, indicate a need for recalibration. Calibrations and tests must be... necessary for performance of the material control tests required by § 74.53(b). (e) Measurement control. The...

  19. 10 CFR 74.59 - Quality assurance and accounting requirements.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... analyses and evaluations of the design, installation, preoperational tests, calibration, and operation of... performed at a pre-determined frequency, indicate a need for recalibration. Calibrations and tests must be... necessary for performance of the material control tests required by § 74.53(b). (e) Measurement control. The...

  20. Nutritional equivalency evaluation of transgenic maize grain from event DP-O9814O-6 and transgenic soybeans containing event DP-356O43-5: laying hen performance and egg quality measures.

    PubMed

    McNaughton, J; Roberts, M; Rice, D; Smith, B; Hinds, M; Delaney, B; Iiams, C; Sauber, T

    2011-02-01

    The objective of this study was to compare the nutritional performance of laying hens fed maize grain from event DP-Ø9814Ø-6 (98140; gat4621 and zm-hra genes) and processed soybean meal from soybeans containing event DP-356Ø43-5 (356043; gat4601 and gm-hra genes), individually or in combination, with the performance of hens fed diets containing nontransgenic maize and soybean meal. Healthy pullets (n = 216) placed in cages (3 hens/cage) were randomly assigned to 9 dietary treatments (8 cages/treatment): nontransgenic controls 1, 2, and 3 (comparable genetic background controls for 98140, 356043, and 98140 + 356043, respectively); reference 1, reference 2, and reference 3 (commercially available nontransgenic maize-soybean meal sources); and 98140 (test 1), 356043 (test 2), and 98140 + 356043 (test 3). The experiment was divided into three 4-wk phases (24 to 28 wk, 28 to 32 wk, and 32 to 36 wk of age), during which time hens were fed mash diets. Performance (BW, feed intake, and egg production) and egg quality data were collected. Data were analyzed using a mixed model ANOVA; differences between the control and respective test group means were considered significant at P < 0.05. Data generated from the reference groups were used only in the estimation of experimental variability and in generating the tolerance interval. Body weight and BW gain, egg production, and production efficiency for hens fed the test diets were similar to the respective values for hens fed the corresponding control diets. Haugh unit measures and egg component weights were similar between the respective test and control groups, and no differences were observed in quality grades or crack measures. All observed values of the control and test groups were within the calculated tolerance intervals. This research indicates that the performance and egg quality of hens fed diets containing 98140 maize grain, 356043 soybean meal, or a combination of the 2 was comparable with that of hens fed diets formulated with nontransgenic maize grain or soybean meal control diets with comparable genetic backgrounds.

  1. Importance of good manufacturing practices in microbiological monitoring in processing human tissues for transplant.

    PubMed

    Pianigiani, Elisa; Ierardi, Francesca; Fimiani, Michele

    2013-12-01

    Skin allografts represent an important therapeutic resource in the treatment of severe skin loss. The risk associated with application of processed tissues in humans is very low, however, human material always carries the risk of disease transmission. To minimise the risk of contamination of grafts, processing is carried out in clean rooms where air quality is monitored. Procedures and quality control tests are performed to standardise the production process and to guarantee the final product for human use. Since we only validate and distribute aseptic tissues, we conducted a study to determine what type of quality controls for skin processing are the most suitable for detecting processing errors and intercurrent contamination, and for faithfully mapping the process without unduly increasing production costs. Two different methods for quality control were statistically compared using the Fisher exact test. On the basis of the current study we selected our quality control procedure based on pre- and post-processing tissue controls, operator and environmental controls. Evaluation of the predictability of our control methods showed that tissue control was the most reliable method of revealing microbial contamination of grafts. We obtained 100 % sensitivity by doubling tissue controls, while maintaining high specificity (77 %).

  2. Quality control of measurements made on fixed-area sample plots

    Treesearch

    Ola Lindgren

    2000-01-01

    The paper describes results from a large program for quality control of forest measurements. The performance of 87 surveyors was evaluated. Tree heights were usually measured well, whereas the counting of tree-rings on increment cores was a source of considerable bias for many surveyors. During tree count on sample plots, many surveyors had a tendency to forget trees,...

  3. Analysis and quality control of carbohydrates in therapeutic proteins with fluorescence HPLC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Kun; Huang, Jian; Center for Informational Biology, University of Electronic Science and Technology of China, Chengdu 610054

    Conbercept is an Fc fusion protein with very complicated carbohydrate profiles which must be carefully monitored through manufacturing process. Here, we introduce an optimized fluorescence derivatization high-performance liquid chromatographic method for glycan mapping in conbercept. Compared with conventional glycan analysis method, this method has much better resolution and higher reproducibility making it excellent for product quality control.

  4. Satisfaction monitoring for quality control in campground management

    Treesearch

    Wilbur F. LaPage; Malcolm I. Bevins

    1981-01-01

    A 4-year study of camper satisfaction indicates that satisfaction monitoring is a useful tool for campground managers to assess their performance and achieve a high level of quality control in their service to the public. An indication of camper satisfaction with campground management is gained from a report card on which a small sample of visitors rates 14 elements of...

  5. Frequency analysis of urban runoff quality in an urbanizing catchment of Shenzhen, China

    NASA Astrophysics Data System (ADS)

    Qin, Huapeng; Tan, Xiaolong; Fu, Guangtao; Zhang, Yingying; Huang, Yuefei

    2013-07-01

    This paper investigates the frequency distribution of urban runoff quality indicators using a long-term continuous simulation approach and evaluates the impacts of proposed runoff control schemes on runoff quality in an urbanizing catchment in Shenzhen, China. Four different indicators are considered to provide a comprehensive assessment of the potential impacts: total runoff depth, event pollutant load, Event Mean Concentration, and peak concentration during a rainfall event. The results obtained indicate that urban runoff quantity and quality in the catchment have significant variations in rainfall events and a very high rate of non-compliance with surface water quality regulations. Three runoff control schemes with the capacity to intercept an initial runoff depth of 5 mm, 10 mm, and 15 mm are evaluated, respectively, and diminishing marginal benefits are found with increasing interception levels in terms of water quality improvement. The effects of seasonal variation in rainfall events are investigated to provide a better understanding of the performance of the runoff control schemes. The pre-flood season has higher risk of poor water quality than other seasons after runoff control. This study demonstrates that frequency analysis of urban runoff quantity and quality provides a probabilistic evaluation of pollution control measures, and thus helps frame a risk-based decision making for urban runoff quality management in an urbanizing catchment.

  6. A simulation investigation of scout/attack helicopter directional control requirements for hover and low-speed tasks

    NASA Technical Reports Server (NTRS)

    Bivens, Courtland C.; Guercio, Joseph G.

    1987-01-01

    A piloted simulator experiment was conducted to investigate directional axis handling qualities requirements for low speed and hover tasks performed by a Scout/Attack helicopter. Included were the directional characteristics of various candidate light helicopter family configurations. Also, the experiment focused on conventional single main/tail rotor configurations of the OH-58 series aircraft, where the first-order yaw-axis dynamic effects that contributed to the loss of tail rotor control were modeled. Five pilots flew 22 configurations under various wind conditions. Cooper-Harper handling quality ratings were used as the primary measure of merit of each configuration. The results of the experiment indicate that rotorcraft configurations with high directional gust sensitivity require greater minimum yaw damping to maintain satisfactory handling qualities during nap-of-the-Earth flying tasks. It was also determined that both yaw damping and control response are critical handling qualities parameters in performing the air-to-air target acquisition and tracking task. Finally, the lack of substantial yaw damping and larger values of gust sensitivity increased the possibility of loss of directional control at low airspeeds for the single main/tail rotor configurations.

  7. Assays for Qualification and Quality Stratification of Clinical Biospecimens Used in Research: A Technical Report from the ISBER Biospecimen Science Working Group.

    PubMed

    Betsou, Fay; Bulla, Alexandre; Cho, Sang Yun; Clements, Judith; Chuaqui, Rodrigo; Coppola, Domenico; De Souza, Yvonne; De Wilde, Annemieke; Grizzle, William; Guadagni, Fiorella; Gunter, Elaine; Heil, Stacey; Hodgkinson, Verity; Kessler, Joseph; Kiehntopf, Michael; Kim, Hee Sung; Koppandi, Iren; Shea, Katheryn; Singh, Rajeev; Sobel, Marc; Somiari, Stella; Spyropoulos, Demetri; Stone, Mars; Tybring, Gunnel; Valyi-Nagy, Klara; Van den Eynden, Gert; Wadhwa, Lalita

    2016-10-01

    This technical report presents quality control (QC) assays that can be performed in order to qualify clinical biospecimens that have been biobanked for use in research. Some QC assays are specific to a disease area. Some QC assays are specific to a particular downstream analytical platform. When such a qualification is not possible, QC assays are presented that can be performed to stratify clinical biospecimens according to their biomolecular quality.

  8. Assays for Qualification and Quality Stratification of Clinical Biospecimens Used in Research: A Technical Report from the ISBER Biospecimen Science Working Group

    PubMed Central

    Bulla, Alexandre; Cho, Sang Yun; Clements, Judith; Chuaqui, Rodrigo; Coppola, Domenico; De Souza, Yvonne; De Wilde, Annemieke; Grizzle, William; Guadagni, Fiorella; Gunter, Elaine; Heil, Stacey; Hodgkinson, Verity; Kessler, Joseph; Kiehntopf, Michael; Kim, Hee Sung; Koppandi, Iren; Shea, Katheryn; Singh, Rajeev; Sobel, Marc; Somiari, Stella; Spyropoulos, Demetri; Stone, Mars; Tybring, Gunnel; Valyi-Nagy, Klara; Van den Eynden, Gert; Wadhwa, Lalita

    2016-01-01

    This technical report presents quality control (QC) assays that can be performed in order to qualify clinical biospecimens that have been biobanked for use in research. Some QC assays are specific to a disease area. Some QC assays are specific to a particular downstream analytical platform. When such a qualification is not possible, QC assays are presented that can be performed to stratify clinical biospecimens according to their biomolecular quality. PMID:27046294

  9. Clinical Quality Performance in U.S. Health Centers

    PubMed Central

    Shi, Leiyu; Lebrun, Lydie A; Zhu, Jinsheng; Hayashi, Arthur S; Sharma, Ravi; Daly, Charles A; Sripipatana, Alek; Ngo-Metzger, Quyen

    2012-01-01

    Objective To describe current clinical quality among the nation's community health centers and to examine health center characteristics associated with performance excellence. Data Sources National data from the 2009 Uniform Data System. Data Collection/Extraction Methods Health centers reviewed patient records and reported aggregate data to the Uniform Data System. Study Design Six measures were examined: first-trimester prenatal care, childhood immunization completion, Pap tests, low birth weight, controlled hypertension, and controlled diabetes. The top 25 percent performing centers were compared with lower performing (bottom 75 percent) centers on these measures. Logistic regressions were utilized to assess the impact of patient, provider, and institutional characteristics on health center performance. Principal Findings Clinical care and outcomes among health centers were generally comparable to national averages. For instance, 67 percent of pregnant patients received timely prenatal care (national = 68 percent), 69 percent of children achieved immunization completion (national = 67 percent), and 63 percent of hypertensive patients had blood pressure under control (national = 48 percent). Depending on the measure, centers with more uninsured patients were less likely to do well, while centers with more physicians and enabling service providers were more likely to do well. Conclusions Health centers provide quality care at rates comparable to national averages. Performance may be improved by increasing insurance coverage among patients and increasing the ratios of physicians and enabling service providers to patients. PMID:22594465

  10. Compensation for time delay in flight simulator visual-display systems

    NASA Technical Reports Server (NTRS)

    Crane, D. F.

    1983-01-01

    A piloted aircraft can be viewed as a closed-loop, man-machine control system. When a simulator pilot is performing a precision maneuver, a delay in the visual display of aircraft response to pilot-control input decreases the stability of the pilot-aircraft system. The less stable system is more difficult to control precisely. Pilot dynamic response and performance change as the pilot attempts to compensate for the decrease in system stability, and these changes bias the simulation results by influencing the pilot's rating of the handling qualities of the simulated aircraft. Delay compensation, designed to restore pilot-aircraft system stability, was evaluated in several studies which are reported here. The studies range from single-axis, tracking-task experiments (with sufficient subjects and trials to establish statistical significance of the results) to a brief evaluation of compensation of a computer-generated-imagery (CGI) visual display system in a full six-degree-of-freedom simulation. The compensation was effective - improvements in pilot performance and workload or aircraft handling-qualities rating (HQR) were observed. Results from recent aircraft handling-qualities research literature which support the compensation design approach are also reviewed.

  11. Performance evaluation of traffic sensing and control devices : [technical summary].

    DOT National Transportation Integrated Search

    2011-01-01

    High quality sensing and control systems are essential for providing efficient signalized arterial operations. INDOT operates over 2600 traffic signal controllers, approximately 2000 of which use some form of vehicle detection. The private sector con...

  12. Control Reallocation Strategies for Damage Adaptation in Transport Class Aircraft

    NASA Technical Reports Server (NTRS)

    Gundy-Burlet, Karen; Krishnakumar, K.; Limes, Greg; Bryant, Don

    2003-01-01

    This paper examines the feasibility, potential benefits and implementation issues associated with retrofitting a neural-adaptive flight control system (NFCS) to existing transport aircraft, including both cable/hydraulic and fly-by-wire configurations. NFCS uses a neural network based direct adaptive control approach for applying alternate sources of control authority in the presence of damage or failures in order to achieve desired flight control performance. Neural networks are used to provide consistent handling qualities across flight conditions, adapt to changes in aircraft dynamics and to make the controller easy to apply when implemented on different aircraft. Full-motion piloted simulation studies were performed on two different transport models: the Boeing 747-400 and the Boeing C-17. Subjects included NASA, Air Force and commercial airline pilots. Results demonstrate the potential for improving handing qualities and significantly increased survivability rates under various simulated failure conditions.

  13. Design and numerical evaluation of full-authority flight control systems for conventional and thruster-augmented helicopters employed in NOE operations

    NASA Technical Reports Server (NTRS)

    Perri, Todd A.; Mckillip, R. M., Jr.; Curtiss, H. C., Jr.

    1987-01-01

    The development and methodology is presented for development of full-authority implicit model-following and explicit model-following optimal controllers for use on helicopters operating in the Nap-of-the Earth (NOE) environment. Pole placement, input-output frequency response, and step input response were used to evaluate handling qualities performance. The pilot was equipped with velocity-command inputs. A mathematical/computational trajectory optimization method was employed to evaluate the ability of each controller to fly NOE maneuvers. The method determines the optimal swashplate and thruster input histories from the helicopter's dynamics and the prescribed geometry and desired flying qualities of the maneuver. Three maneuvers were investigated for both the implicit and explicit controllers with and without auxiliary propulsion installed: pop-up/dash/descent, bob-up at 40 knots, and glideslope. The explicit controller proved to be superior to the implicit controller in performance and ease of design.

  14. Internal quality control practice of thyroid disease related tests and imprecision analysis in China.

    PubMed

    Hu, Li-Tao; Wang, Zhi-Guo

    2014-01-01

    Internal quality control (IQC) has a long and well-established role in clinical laboratories and the quality of laboratories has achieved great improvement in China. However, the practice of IQC varies significantly between institutions and many problems still exists. Consequently, the Chinese National Center for Clinical Laboratories has been undertaking monthly nation-wide surveys of current IQC practice of tests since 2010 to monitor laboratory quality. Thyroid disease related tests were chosen for this research. Different numbers of laboratories in China participating national external quality assessment (EQA) schemes of Total Thyroxine (TT4), Total Triiodothyronine (TT3), Free Thyroxine (FT4) and Free Triiodothyronine (FT3) tests, and Thyroid Stimulating Hormone (TSH) measurements, were required to report the IQC information though the national external quality assessment (EQA) network platform. Survey data showed significant variability in all aspects of IQC practice. More than half of the laboratories are using a single concentration level of IQC material and up to 28.6% of the laboratories only use 1(2s) or 1(3s) to monitor IQC results for FT3, TT3, FT4, TT4, and TSH. The medians of the average time intervals of two control tests for FT3, TT3, FT4, TT4, and TSH are 33.6, 35.4, 33.6, 35.4, and 33.6 hours, respectively, more or less 1.4 days. When quality specifications based on biological variation are applied to imprecision evaluation, only 46.3%, 52.1%, 31.3%, 12.8%, and 5.86% laboratories meet the minimum performance for FT3, TT3, FT4, and TT4, 24.5%, 23.6%, 12.8%, and 5.86% of the all meet the desirable performance, and 4.4%, 3.9%, 2.5% and 3.0% of the all meet the optimal performance. While it shows a higher percentage of acceptable laboratories (98.1%, 87.9% and 39.0% meeting the minimum, desirable and optimal performance, respectively) for TSH. Not-well-designed IQC practices may affect the effectiveness of laboratory IQC and, thus, the adequacy of a laboratory to monitor system performance. Consequently, IQC practice should be designed according to performance of measure method and instrument. Both clinical laboratories and the government should make efforts to improve quality of clinical testing to ensure the patients' safety.

  15. A comprehensive analysis of the IMRT dose delivery process using statistical process control (SPC)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gerard, Karine; Grandhaye, Jean-Pierre; Marchesi, Vincent

    The aim of this study is to introduce tools to improve the security of each IMRT patient treatment by determining action levels for the dose delivery process. To achieve this, the patient-specific quality control results performed with an ionization chamber--and which characterize the dose delivery process--have been retrospectively analyzed using a method borrowed from industry: Statistical process control (SPC). The latter consisted in fulfilling four principal well-structured steps. The authors first quantified the short term variability of ionization chamber measurements regarding the clinical tolerances used in the cancer center ({+-}4% of deviation between the calculated and measured doses) by calculatingmore » a control process capability (C{sub pc}) index. The C{sub pc} index was found superior to 4, which implies that the observed variability of the dose delivery process is not biased by the short term variability of the measurement. Then, the authors demonstrated using a normality test that the quality control results could be approximated by a normal distribution with two parameters (mean and standard deviation). Finally, the authors used two complementary tools--control charts and performance indices--to thoroughly analyze the IMRT dose delivery process. Control charts aim at monitoring the process over time using statistical control limits to distinguish random (natural) variations from significant changes in the process, whereas performance indices aim at quantifying the ability of the process to produce data that are within the clinical tolerances, at a precise moment. The authors retrospectively showed that the analysis of three selected control charts (individual value, moving-range, and EWMA control charts) allowed efficient drift detection of the dose delivery process for prostate and head-and-neck treatments before the quality controls were outside the clinical tolerances. Therefore, when analyzed in real time, during quality controls, they should improve the security of treatments. They also showed that the dose delivery processes in the cancer center were in control for prostate and head-and-neck treatments. In parallel, long term process performance indices (P{sub p}, P{sub pk}, and P{sub pm}) have been analyzed. Their analysis helped defining which actions should be undertaken in order to improve the performance of the process. The prostate dose delivery process has been shown statistically capable (0.08% of the results is expected to be outside the clinical tolerances) contrary to the head-and-neck dose delivery process (5.76% of the results are expected to be outside the clinical tolerances).« less

  16. A comprehensive analysis of the IMRT dose delivery process using statistical process control (SPC).

    PubMed

    Gérard, Karine; Grandhaye, Jean-Pierre; Marchesi, Vincent; Kafrouni, Hanna; Husson, François; Aletti, Pierre

    2009-04-01

    The aim of this study is to introduce tools to improve the security of each IMRT patient treatment by determining action levels for the dose delivery process. To achieve this, the patient-specific quality control results performed with an ionization chamber--and which characterize the dose delivery process--have been retrospectively analyzed using a method borrowed from industry: Statistical process control (SPC). The latter consisted in fulfilling four principal well-structured steps. The authors first quantified the short-term variability of ionization chamber measurements regarding the clinical tolerances used in the cancer center (+/- 4% of deviation between the calculated and measured doses) by calculating a control process capability (C(pc)) index. The C(pc) index was found superior to 4, which implies that the observed variability of the dose delivery process is not biased by the short-term variability of the measurement. Then, the authors demonstrated using a normality test that the quality control results could be approximated by a normal distribution with two parameters (mean and standard deviation). Finally, the authors used two complementary tools--control charts and performance indices--to thoroughly analyze the IMRT dose delivery process. Control charts aim at monitoring the process over time using statistical control limits to distinguish random (natural) variations from significant changes in the process, whereas performance indices aim at quantifying the ability of the process to produce data that are within the clinical tolerances, at a precise moment. The authors retrospectively showed that the analysis of three selected control charts (individual value, moving-range, and EWMA control charts) allowed efficient drift detection of the dose delivery process for prostate and head-and-neck treatments before the quality controls were outside the clinical tolerances. Therefore, when analyzed in real time, during quality controls, they should improve the security of treatments. They also showed that the dose delivery processes in the cancer center were in control for prostate and head-and-neck treatments. In parallel, long-term process performance indices (P(p), P(pk), and P(pm)) have been analyzed. Their analysis helped defining which actions should be undertaken in order to improve the performance of the process. The prostate dose delivery process has been shown statistically capable (0.08% of the results is expected to be outside the clinical tolerances) contrary to the head-and-neck dose delivery process (5.76% of the results are expected to be outside the clinical tolerances).

  17. A novel non-uniform control vector parameterization approach with time grid refinement for flight level tracking optimal control problems.

    PubMed

    Liu, Ping; Li, Guodong; Liu, Xinggao; Xiao, Long; Wang, Yalin; Yang, Chunhua; Gui, Weihua

    2018-02-01

    High quality control method is essential for the implementation of aircraft autopilot system. An optimal control problem model considering the safe aerodynamic envelop is therefore established to improve the control quality of aircraft flight level tracking. A novel non-uniform control vector parameterization (CVP) method with time grid refinement is then proposed for solving the optimal control problem. By introducing the Hilbert-Huang transform (HHT) analysis, an efficient time grid refinement approach is presented and an adaptive time grid is automatically obtained. With this refinement, the proposed method needs fewer optimization parameters to achieve better control quality when compared with uniform refinement CVP method, whereas the computational cost is lower. Two well-known flight level altitude tracking problems and one minimum time cost problem are tested as illustrations and the uniform refinement control vector parameterization method is adopted as the comparative base. Numerical results show that the proposed method achieves better performances in terms of optimization accuracy and computation cost; meanwhile, the control quality is efficiently improved. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  18. Proactive palliative care for patients with COPD (PROLONG): a pragmatic cluster controlled trial

    PubMed Central

    Duenk, RG; Verhagen, C; Bronkhorst, EM; van Mierlo, PJWB; Broeders, MEAC; Collard, SM; Dekhuijzen, PNR; Vissers, KCP

    2017-01-01

    Background and aim Patients with advanced chronic obstructive pulmonary disease (COPD) have poor quality of life. The aim of this study was to assess the effects of proactive palliative care on the well-being of these patients. Trial registration This trial is registered with the Netherlands Trial Register, NTR4037. Patients and methods A pragmatic cluster controlled trial (quasi-experimental design) was performed with hospitals as cluster (three intervention and three control) and a pretrial assessment was performed. Hospitals were selected for the intervention group based on the presence of a specialized palliative care team (SPCT). To control for confounders, a pretrial assessment was performed in which hospitals were compared on baseline characteristics. Patients with COPD with poor prognosis were recruited during hospitalization for acute exacerbation. All patients received usual care while patients in the intervention group received additional proactive palliative care in monthly meetings with an SPCT. Our primary outcome was change in quality of life score after 3 months, which was measured using the St George Respiratory Questionnaire (SGRQ). Secondary outcomes were, among others, quality of life at 6, 9 and 12 months; readmissions: survival; and having made advance care planning (ACP) choices. All analyses were performed following the principle of intention to treat. Results During the year 2014, 228 patients (90 intervention and 138 control) were recruited and at 3 months, 163 patients (67 intervention and 96 control) completed the SGRQ. There was no significant difference in change scores of the SGRQ total at 3 months between groups (−0.79 [95% CI, −4.61 to 3.34], p=0.70). However, patients who received proactive palliative care experienced less impact of their COPD (SGRQ impact subscale) at 6 months (−6.22 [−11.73 to −0.71], p=0.04) and had more often made ACP choices (adjusted odds ratio 3.26 [1.49–7.14], p=0.003). Other secondary outcomes were not significantly different. Conclusion Proactive palliative care did not improve the overall quality of life of patients with COPD. However, patients more often made ACP choices which may lead to better quality of care toward the end of life. PMID:29033560

  19. Measuring the quality of therapeutic apheresis care in the pediatric intensive care unit.

    PubMed

    Sussmane, Jeffrey B; Torbati, Dan; Gitlow, Howard S

    2012-01-01

    Our goal was to measure the quality of care provided in the Pediatric Intensive Care Unit (PICU) during Therapeutic Apheresis (TA). We described the care as a step by step process. We designed a flow chart to carefully document each step of the process. We then defined each step with a unique clinical indictor (CI) that represented the exact task we felt provided quality care. These CIs were studied and modified for 1 year. We measured our performance in this process by the number of times we accomplished the CI vs. the total number of CIs that were to be performed. The degree of compliance, with these clinical indicators, was analyzed and used as a metric for quality by calculating how close the process is running exactly as planned or "in control." The Apheresis Process was in control (compliance) for 47% of the indicators, as measured in the aggregate for the first observational year. We then applied the theory of Total Quality Management (TQM) through our Design, Measure, Analyze, Improve, and Control (DMAIC) model. We were able to improve the process and bring it into control by increasing the compliance to > 99.74%, in the aggregate, for the third and fourth quarter of the second year. We have implemented TQM to increase compliance, thus control, of a highly complex and multidisciplinary Pediatric Intensive Care therapy. We have shown a reproducible and scalable measure of quality for a complex clinical process in the PICU, without additional capital expenditure. Copyright © 2011 Wiley-Liss, Inc.

  20. Database Performance Monitoring for the Photovoltaic Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klise, Katherine A.

    The Database Performance Monitoring (DPM) software (copyright in processes) is being developed at Sandia National Laboratories to perform quality control analysis on time series data. The software loads time indexed databases (currently csv format), performs a series of quality control tests defined by the user, and creates reports which include summary statistics, tables, and graphics. DPM can be setup to run on an automated schedule defined by the user. For example, the software can be run once per day to analyze data collected on the previous day. HTML formatted reports can be sent via email or hosted on a website.more » To compare performance of several databases, summary statistics and graphics can be gathered in a dashboard view which links to detailed reporting information for each database. The software can be customized for specific applications.« less

  1. Sigma metrics as a tool for evaluating the performance of internal quality control in a clinical chemistry laboratory

    PubMed Central

    Kumar, B. Vinodh; Mohan, Thuthi

    2018-01-01

    OBJECTIVE: Six Sigma is one of the most popular quality management system tools employed for process improvement. The Six Sigma methods are usually applied when the outcome of the process can be measured. This study was done to assess the performance of individual biochemical parameters on a Sigma Scale by calculating the sigma metrics for individual parameters and to follow the Westgard guidelines for appropriate Westgard rules and levels of internal quality control (IQC) that needs to be processed to improve target analyte performance based on the sigma metrics. MATERIALS AND METHODS: This is a retrospective study, and data required for the study were extracted between July 2015 and June 2016 from a Secondary Care Government Hospital, Chennai. The data obtained for the study are IQC - coefficient of variation percentage and External Quality Assurance Scheme (EQAS) - Bias% for 16 biochemical parameters. RESULTS: For the level 1 IQC, four analytes (alkaline phosphatase, magnesium, triglyceride, and high-density lipoprotein-cholesterol) showed an ideal performance of ≥6 sigma level, five analytes (urea, total bilirubin, albumin, cholesterol, and potassium) showed an average performance of <3 sigma level and for level 2 IQCs, same four analytes of level 1 showed a performance of ≥6 sigma level, and four analytes (urea, albumin, cholesterol, and potassium) showed an average performance of <3 sigma level. For all analytes <6 sigma level, the quality goal index (QGI) was <0.8 indicating the area requiring improvement to be imprecision except cholesterol whose QGI >1.2 indicated inaccuracy. CONCLUSION: This study shows that sigma metrics is a good quality tool to assess the analytical performance of a clinical chemistry laboratory. Thus, sigma metric analysis provides a benchmark for the laboratory to design a protocol for IQC, address poor assay performance, and assess the efficiency of existing laboratory processes. PMID:29692587

  2. Long-term pavement performance indicators for failed materials.

    DOT National Transportation Integrated Search

    2016-04-01

    State Transportation Agencies (STAs) use quality control/quality assurance (QC/QA) specifications to guide the testing and inspection of : road pavement construction. Although failed materials of pavement rarely occur in practice, it is critical to h...

  3. Inhibitory Control Mediates the Association between Perceived Stress and Secure Relationship Quality.

    PubMed

    Herd, Toria; Li, Mengjiao; Maciejewski, Dominique; Lee, Jacob; Deater-Deckard, Kirby; King-Casas, Brooks; Kim-Spoon, Jungmeen

    2018-01-01

    Past research has demonstrated negative associations between exposure to stressors and quality of interpersonal relationships among children and adolescents. Nevertheless, underlying mechanisms of this association remain unclear. Chronic stress has been shown to disrupt prefrontal functioning in the brain, including inhibitory control abilities, and evidence is accumulating that inhibitory control may play an important role in secure interpersonal relationship quality, including peer problems and social competence. In this prospective longitudinal study, we examine whether changes in inhibitory control, measured at both behavioral and neural levels, mediate the association between stress and changes in secure relationship quality with parents and peers. The sample included 167 adolescents (53% males) who were first recruited at age 13 or 14 years and assessed annually three times. Adolescents' inhibitory control was measured by their behavioral performance and brain activities, and adolescents self-reported perceived stress levels and relationship quality with mothers, fathers, and peers. Results suggest that behavioral inhibitory control mediates the association between perceived stress and adolescent's secure relationship quality with their mothers and fathers, but not their peers. In contrast, given that stress was not significantly correlated with neural inhibitory control, we did not further test the mediation path. Our results highlight the role of inhibitory control as a process through which stressful life experiences are related to impaired secure relationship quality between adolescents and their mothers and fathers.

  4. Inhibitory Control Mediates the Association between Perceived Stress and Secure Relationship Quality

    PubMed Central

    Herd, Toria; Li, Mengjiao; Maciejewski, Dominique; Lee, Jacob; Deater-Deckard, Kirby; King-Casas, Brooks; Kim-Spoon, Jungmeen

    2018-01-01

    Past research has demonstrated negative associations between exposure to stressors and quality of interpersonal relationships among children and adolescents. Nevertheless, underlying mechanisms of this association remain unclear. Chronic stress has been shown to disrupt prefrontal functioning in the brain, including inhibitory control abilities, and evidence is accumulating that inhibitory control may play an important role in secure interpersonal relationship quality, including peer problems and social competence. In this prospective longitudinal study, we examine whether changes in inhibitory control, measured at both behavioral and neural levels, mediate the association between stress and changes in secure relationship quality with parents and peers. The sample included 167 adolescents (53% males) who were first recruited at age 13 or 14 years and assessed annually three times. Adolescents’ inhibitory control was measured by their behavioral performance and brain activities, and adolescents self-reported perceived stress levels and relationship quality with mothers, fathers, and peers. Results suggest that behavioral inhibitory control mediates the association between perceived stress and adolescent’s secure relationship quality with their mothers and fathers, but not their peers. In contrast, given that stress was not significantly correlated with neural inhibitory control, we did not further test the mediation path. Our results highlight the role of inhibitory control as a process through which stressful life experiences are related to impaired secure relationship quality between adolescents and their mothers and fathers. PMID:29535664

  5. Ultra-performance liquid chromatography fingerprinting for quality control of Phragmitis rhizoma (Lugen) produced in Baiyangdian

    PubMed Central

    Li, Hong; Gao, Yu-Mei; Zhang, Jing; Wang, Lin; Wang, Xiao-Xin

    2013-01-01

    Objective: To establish an ultra-performance liquid chromatography (UPLC) fingerprinting method for quality control of Phragmitis rhizoma from Baiyangdian. Materials and Methods: Ultrasonic extraction with 70% methanol was performed on 10 samples of P. rhizoma collected from 10 different villages in Baiyangdian. The sample solutions were analyzed by Waters UPLC equipped with the ACQUITY UPLC BEH C18 column and photodiode array (PDA) detector, and gradient eluted with acetonitrile/water as the mobile phase. The flow rate was set to 0.1 mL/min; the column temperature was set to 25°C; and the detection wavelength was set to 285 nm. Results: The chromatograms of the 10 samples showed 27 common peaks, of which one was identified as the ferulic acid standard. The similarity indexes were all above 0.82. Hierarchical cluster analysis showed that the constituents and their quantities differed according to the diameter of the original plant, which is related to its age. Conclusion: The UPLC fingerprinting method had the advantages of being fast, accurate, and highly efficient; this indicated that it can be used for quality control of P. rhizoma produced in Baiyangdian. Also, the relation between the quality and diameter/age of the plant needs to be further investigated. PMID:24124278

  6. Handling Qualities Implications for Crewed Spacecraft Operations

    NASA Technical Reports Server (NTRS)

    Bailey, Randall E.; Jackson, E. Bruce; Arthur, J. J.

    2012-01-01

    Abstract Handling qualities embody those qualities or characteristics of an aircraft that govern the ease and precision with which a pilot is able to perform the tasks required in support of an aircraft role. These same qualities are as critical, if not more so, in the operation of spacecraft. A research, development, test, and evaluation process was put into effect to identify, understand, and interpret the engineering and human factors principles which govern the pilot-vehicle dynamic system as they pertain to space exploration missions and tasks. Toward this objective, piloted simulations were conducted at the NASA Langley Research Center and Ames Research Center for earth-orbit proximity operations and docking and lunar landing. These works provide broad guidelines for the design of spacecraft to exhibit excellent handling characteristics. In particular, this work demonstrates how handling qualities include much more than just stability and control characteristics of a spacecraft or aircraft. Handling qualities are affected by all aspects of the pilot-vehicle dynamic system, including the motion, visual and aural cues of the vehicle response as the pilot performs the required operation or task. A holistic approach to spacecraft design, including the use of manual control, automatic control, and pilot intervention/supervision is described. The handling qualities implications of design decisions are demonstrated using these pilot-in-the-loop evaluations of docking operations and lunar landings.

  7. Global chemical profiling based quality evaluation approach of rhubarb using ultra performance liquid chromatography with tandem quadrupole time-of-flight mass spectrometry.

    PubMed

    Zhang, Li; Liu, Haiyu; Qin, Lingling; Zhang, Zhixin; Wang, Qing; Zhang, Qingqing; Lu, Zhiwei; Wei, Shengli; Gao, Xiaoyan; Tu, Pengfei

    2015-02-01

    A global chemical profiling based quality evaluation approach using ultra performance liquid chromatography with tandem quadrupole time-of-flight mass spectrometry was developed for the quality evaluation of three rhubarb species, including Rheum palmatum L., Rheum tanguticum Maxim. ex Balf., and Rheum officinale Baill. Considering that comprehensive detection of chemical components is crucial for the global profile, a systemic column performance evaluation method was developed. Based on this, a Cortecs column was used to acquire the chemical profile, and Chempattern software was employed to conduct similarity evaluation and hierarchical cluster analysis. The results showed R. tanguticum could be differentiated from R. palmatum and R. officinale at the similarity value 0.65, but R. palmatum and R. officinale could not be distinguished effectively. Therefore, a common pattern based on three rhubarb species was developed to conduct the quality evaluation, and the similarity value 0.50 was set as an appropriate threshold to control the quality of rhubarb. A total of 88 common peaks were identified by their accurate mass and fragmentation, and partially verified by reference standards. Through the verification, the newly developed method could be successfully used for evaluating the holistic quality of rhubarb. It would provide a reference for the quality control of other herbal medicines. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Some Inspection Methods for Quality Control and In-service Inspection of GLARE

    NASA Astrophysics Data System (ADS)

    Sinke, J.

    2003-07-01

    Quality control of materials and structures is an important issue, also for GLARE. During the manufacturing stage the processes and materials should be monitored and checked frequently in order to obtain a qualified product. During the operation of the aircraft, frequent monitoring and inspections are performed to maintain the quality at a prescribed level. Therefore, in-service inspection methods are applied, and when necessary repair activities are conducted. For the quality control of the GLARE panels and components during manufacturing, the C-scan method proves to be an effective tool. For in-service inspection the Eddy Current Method is one of the suitable options. In this paper a brief overview is presented of both methods and their application on GLARE products.

  9. Strategies of performance self-monitoring in automotive production.

    PubMed

    Faye, Hélène; Falzon, Pierre

    2009-09-01

    Production in the automotive industry, based on assembly line work, is now characterized by lean manufacturing and customization. This results in greater flexibility and increased quality demands, including worker performance self-monitoring. The objectives of this study are to refine the concept of performance self-monitoring and to characterize the strategies developed by operators to achieve it. Data were collected based on the method of individual auto-confrontation, consisting of two steps: eleven assembly-line operators of a French automotive company were individually observed and video-taped while they were working; an interview then allowed each operator to discuss his/her activity based on the video-tape. This study expands the concept of performance self-monitoring by highlighting three types of strategies directly oriented toward quality: prevention, feedback control and control action strategies.

  10. Analytical performance evaluation of a high-volume hematology laboratory utilizing sigma metrics as standard of excellence.

    PubMed

    Shaikh, M S; Moiz, B

    2016-04-01

    Around two-thirds of important clinical decisions about the management of patients are based on laboratory test results. Clinical laboratories are required to adopt quality control (QC) measures to ensure provision of accurate and precise results. Six sigma is a statistical tool, which provides opportunity to assess performance at the highest level of excellence. The purpose of this study was to assess performance of our hematological parameters on sigma scale in order to identify gaps and hence areas of improvement in patient care. Twelve analytes included in the study were hemoglobin (Hb), hematocrit (Hct), red blood cell count (RBC), mean corpuscular volume (MCV), red cell distribution width (RDW), total leukocyte count (TLC) with percentages of neutrophils (Neutr%) and lymphocytes (Lymph %), platelet count (Plt), mean platelet volume (MPV), prothrombin time (PT), and fibrinogen (Fbg). Internal quality control data and external quality assurance survey results were utilized for the calculation of sigma metrics for each analyte. Acceptable sigma value of ≥3 was obtained for the majority of the analytes included in the analysis. MCV, Plt, and Fbg achieved value of <3 for level 1 (low abnormal) control. PT performed poorly on both level 1 and 2 controls with sigma value of <3. Despite acceptable conventional QC tools, application of sigma metrics can identify analytical deficits and hence prospects for the improvement in clinical laboratories. © 2016 John Wiley & Sons Ltd.

  11. Quality evaluation of Desmodium styracifolium using high-performance liquid chromatography with photodiode array detection and electrospray ionisation tandem mass spectrometry.

    PubMed

    Zhou, Chan; Luo, Jian-Guang; Kong, Ling-Yi

    2012-01-01

    Desmodium styracifolium, with C-flavone glycosides as main pharmacological effective compounds, is a popular Chinese medicinal herb and has been used to treat urination disturbance, urolithiasis, edema and jaundice. However, few systematic methods have been reported on the quality control of this natural herb. To develop a method for control the quality of D. styracifolium by combining chromatographic fingerprints and major constituent quantification. Separations were performed on an Ultimate XB-C-18 column by gradient elution using acetonitrile and 0.1% aqueous formic acid. Analytes were identified by HPLC coupled with electrospray ionisation mass spectrometry experiments. Twenty common peaks in chromatographic fingerprints were first identified among 15 batches of D. styracifolium from various regions. On basis of this, a HPLC-PAD method was established to simultaneously quantify five major constituents, which was validated for limit of qualification, linearity and interday variation of precision and accuracy. The assay developed could be considered as a suitable quality control method of D. styracifolium. Copyright © 2011 John Wiley & Sons, Ltd.

  12. Chemical analysis of Panax quinquefolius (North American ginseng): A review.

    PubMed

    Wang, Yaping; Choi, Hyung-Kyoon; Brinckmann, Josef A; Jiang, Xue; Huang, Linfang

    2015-12-24

    Panax quinquefolius (PQ) is one of the best-selling natural health products due to its proposed beneficial anti-aging, anti-cancer, anti-stress, anti-fatigue, and anxiolytic effects. In recent years, the quality of PQ has received considerable attention. Sensitive and accurate methods for qualitative and quantitative analyses of chemical constituents are necessary for the comprehensive quality control to ensure the safety and efficacy of PQ. This article reviews recent progress in the chemical analysis of PQ and its preparations. Numerous analytical techniques, including spectroscopy, thin-layer chromatography (TLC), gas chromatography (GC), high-performance liquid chromatography (HPLC), liquid chromatography/mass spectrometry (LC/MS), high-speed centrifugal partition chromatography (HSCPC), high-performance counter-current chromatography (HPCCC), nuclear magnetic resonance spectroscopy (NMR), and immunoassay, are described. Among these techniques, HPLC coupled with mass spectrometry (MS) is the most promising method for quality control. The challenges encountered in the chemical analysis of PQ are also briefly discussed, and the remaining questions regarding the quality control of PQ that require further investigation are highlighted. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Considering chance in quality and safety performance measures: an analysis of performance reports by boards in English NHS trusts.

    PubMed

    Schmidtke, Kelly Ann; Poots, Alan J; Carpio, Juan; Vlaev, Ivo; Kandala, Ngianga-Bakwin; Lilford, Richard J

    2017-01-01

    Hospital board members are asked to consider large amounts of quality and safety data with a duty to act on signals of poor performance. However, in order to do so it is necessary to distinguish signals from noise (chance). This article investigates whether data in English National Health Service (NHS) acute care hospital board papers are presented in a way that helps board members consider the role of chance in their decisions. Thirty English NHS trusts were selected at random and their board papers retrieved. Charts depicting quality and safety were identified. Categorical discriminations were then performed to document the methods used to present quality and safety data in board papers, with particular attention given to whether and how the charts depicted the role of chance, that is, by including control lines or error bars. Thirty board papers, containing a total of 1488 charts, were sampled. Only 88 (6%) of these charts depicted the role of chance, and only 17 of the 30 board papers included any charts depicting the role of chance. Of the 88 charts that attempted to represent the role of chance, 16 included error bars and 72 included control lines. Only 6 (8%) of the 72 control charts indicated where the control lines had been set (eg, 2 vs 3 SDs). Hospital board members are expected to consider large amounts of information. Control charts can help board members distinguish signals from noise, but often boards are not using them. We discuss demand-side and supply-side barriers that could be overcome to increase use of control charts in healthcare. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  14. Liver phantom for quality control and training in nuclear medicine

    NASA Astrophysics Data System (ADS)

    Lima Ferreira, Fernanda Carla; Souza, Divanizia do Nascimento

    2011-10-01

    In nuclear medicine, liver scintigraphy aims to verify organ function based on the radionuclide concentration in the liver and bile flow and is also used to detect tumors. Therefore it is necessary to perform quality control tests in the gamma camera before running the exam to prevent false results. Quality control tests of the gamma camera should thus be performed before running the exam to prevent false results. Such tests generally use radioactive material inside phantoms for evaluation of gamma camera parameters in quality control procedures. Phantoms can also be useful for training doctors and technicians in nuclear medicine procedures. The phantom proposed here has artifacts that simulate nodules; it may take on different quantities, locations and sizes and it may also be mounted without the introduction of nodules. Thus, its images may show hot or cold nodules or no nodules. The phantom consists of acrylic plates hollowed out in the centre, with the geometry of an adult liver. Images for analyses of simulated liver scintigraphy were obtained with the detector device at 5 cm from the anterior surface of the phantom. These simulations showed that this object is suitable for quality control in nuclear medicine because it was possible to visualize artifacts larger than 7.9 mm using a 256×256 matrix and 1000 kcpm. The phantom constructed in this work will also be useful for training practitioners and technicians in order to prevent patients from repeat testing caused by error during examinations.

  15. Training of U.S. Air Traffic Controllers. (IDA Report No. R-206).

    ERIC Educational Resources Information Center

    Henry, James H.; And Others

    The report reviews the evolution of existing national programs for air traffic controller training, estimates the number of persons requiring developmental and supplementary training, examines present controller selection and training programs, investigates performance measurement methods, considers standardization and quality control, discusses…

  16. Effects of Elastic Resistance Exercise on Muscle Strength and Functional Performance in Healthy Adults: A Systematic Review and Meta-Analysis.

    PubMed

    de Oliveira, Poliana Alves; Blasczyk, Juscelino Castro; Souza Junior, Gerson; Lagoa, Karina Ferreira; Soares, Milene; de Oliveira, Ricardo Jacó; Filho, Paulo José Barbosa Gutierres; Carregaro, Rodrigo Luiz; Martins, Wagner Rodrigues

    2017-04-01

    Elastic Resistance Exercise (ERE) has already demonstrated its effectiveness in older adults and, when combined with the resistance generated by fixed loads, in adults. This review summarizes the effectiveness of ERE performed as isolated method on muscle strength and functional performance in healthy adults. A database search was performed (MEDLine, Cochrane Library, PEDro and Web of Knowledge) to identify controlled clinical trials in English language. The mean difference (MD) with 95% confidence intervals (CIs) and overall effect size were calculated for all comparisons. The PEDro scale was used assess the methodological quality. From the 93 articles identified by the search strategy, 5 met the inclusion criteria, in which 3 presented high quality (PEDro > 6). Meta-analyses demonstrated that the effects of ERE were superior when compared with passive control on functional performance and muscle strength. When compared with active controls, the effect of ERE was inferior on function performance and with similar effect on muscle strength. ERE are effective to improve functional performance and muscle strength when compared with no intervention, in healthy adults. ERE are not superior to other methods of resistance training to improve functional performance and muscle strength in health adults.

  17. Deep breathing exercises performed 2 months following cardiac surgery: a randomized controlled trial.

    PubMed

    Westerdahl, Elisabeth; Urell, Charlotte; Jonsson, Marcus; Bryngelsson, Ing-Liss; Hedenström, Hans; Emtner, Margareta

    2014-01-01

    Postoperative breathing exercises are recommended to cardiac surgery patients. Instructions concerning how long patients should continue exercises after discharge vary, and the significance of treatment needs to be determined. Our aim was to assess the effects of home-based deep breathing exercises performed with a positive expiratory pressure device for 2 months following cardiac surgery. The study design was a prospective, single-blinded, parallel-group, randomized trial. Patients performing breathing exercises 2 months after cardiac surgery (n = 159) were compared with a control group (n = 154) performing no breathing exercises after discharge. The intervention consisted of 30 slow deep breaths performed with a positive expiratory pressure device (10-15 cm H2O), 5 times a day, during the first 2 months after surgery. The outcomes were lung function measurements, oxygen saturation, thoracic excursion mobility, subjective perception of breathing and pain, patient-perceived quality of recovery (40-Item Quality of Recovery score), health-related quality of life (36-Item Short Form Health Survey), and self-reported respiratory tract infection/pneumonia and antibiotic treatment. Two months postoperatively, the patients had significantly reduced lung function, with a mean decrease in forced expiratory volume in 1 second to 93 ± 12% (P< .001) of preoperative values. Oxygenation had returned to preoperative values, and 5 of 8 aspects in the 36-Item Short Form Health Survey were improved compared with preoperative values (P< .01). There were no significant differences between the groups in any of the measured outcomes. No significant differences in lung function, subjective perceptions, or quality of life were found between patients performing home-based deep breathing exercises and control patients 2 months after cardiac surgery.

  18. Real-time measurement of quality during the compaction of subgrade soils.

    DOT National Transportation Integrated Search

    2012-12-01

    Conventional quality control of subgrade soils during their compaction is usually performed by monitoring moisture content and dry density at a few discrete locations. However, randomly selected points do not adequately represent the entire compacted...

  19. Control of a metalorganic chemical vapor deposition process for improved composition and thickness precision in compound semiconductors

    NASA Astrophysics Data System (ADS)

    Gaffney, Monique Suzanne

    1998-11-01

    Metalorganic chemical vapor deposition (MOCVD) is a process used to manufacture electronic and optoelectronic devices that has traditionally lacked real-time growth monitoring and control. Controlling the growth rate and composition using the existing sensors, as well as advanced monitoring systems developed in-house, is shown to improve device quality. Specific MOCVD growth objectives are transformed into controller performance goals. Group III bubbler concentration variations, which perturb both growth rate and composition precision, are identified to be the primary disturbances. First a feed forward control system was investigated, which used an ultrasonic concentration monitor, located upstream in the process. This control strategy resulted in improved regulation of the gallium delivery rate by cancelling the sensed gallium bubbler concentration disturbances via the injection mass flow controller. The controller performance is investigated by growing GaInAs/InP superlattices. Results of growths performed under normal operating conditions and also under large perturbations include X-ray diffraction from the samples as well as real-time sensor signal data. High quality superlattices that display up to eight orders of satellite peaks are obtained under the feed forward compensation scheme, demonstrating improved layer-to-layer reproducibility of thickness and composition. The success of the feed forward control demonstration led to the development of a more complex downstream feedback control system. An ultraviolet absorption monitor was fabricated and retrofitted as a feedback control signal. A control-oriented model of the downstream process was developed for the feedback controller synthesis. Although challenged with both the photolysis and multi-gas detection issues common to UV absorption monitors, closed loop control with the UV sensor was performed and proved to be an effective method of disturbance rejection. An InP/GaInAs test structure was grown under both open and closed loop conditions. During the growth of a bulk GaInAs layer, an indium concentration disturbance was injected by way of the bubbler pressure control valve. The controller goal was to reject this concentration disturbance. The UV absorption real-time data, as well as both X-ray diffraction and photoluminescence post-growth sample measurements were used to evaluate the controller performance. All results indicate that the closed loop control system greatly improved the quality of the perturbed growth.

  20. Optimal quality control of bakers' yeast fed-batch culture using population dynamics.

    PubMed

    Dairaku, K; Izumoto, E; Morikawa, H; Shioya, S; Takamatsu, T

    1982-12-01

    An optimal quality control policy for the overall specific growth rate of bakers' yeast, which maximizes the fermentative activity in the making of bread, was obtained by direct searching based on the mathematical model proposed previously. The mathematical model had described the age distribution of bakers' yeast which had an essential relationship to the ability of fermentation in the making of bread. The mathematical model is a simple aging model with two periods: Nonbudding and budding. Based on the result obtained by direct searching, the quality control of bakers' yeast fed-batch culture was performed and confirmed to be experimentally valid.

  1. Productive performance, egg quality, and hatching traits of Japanese quail reared under different levels of glycerin.

    PubMed

    Ghayas, A; Hussain, J; Mahmud, A; Javed, K; Rehman, A; Ahmad, S; Mehmood, S; Usman, M; Ishaq, H M

    2017-07-01

    This study evaluated subsequent effects of glycerin on productive performance, egg quality, and hatching traits in Japanese quail. A total of 200 birds was arranged according to a completely randomized design into 5 treatment groups having 5 replicates of 8 birds each (6 females and 2 males). Treatments consisted 5 levels of glycerin, i.e., 2.5, 5, 7.5, and 10% and the control group. Birds were fed with different levels of glycerin during a rearing period of 6 wk and their subsequent effects on productive performance, egg quality, and hatching traits were observed. Data were collected regarding productive performance for 16 wk; however, egg quality and hatching traits were recorded during pre-peak (at fourth wk), peak (at 12th wk), and post peak (at 16th wk) phase. Productive performance, egg quality, and hatching traits did not differ significantly throughout the experimental period. It was concluded that glycerin can be used as a replacement energy source, having no effect on productive and reproductive performance in Japanese quail. © 2017 Poultry Science Association Inc.

  2. The Automation of Nowcast Model Assessment Processes

    DTIC Science & Technology

    2016-09-01

    that will automate real-time WRE-N model simulations, collect and quality control check weather observations for assimilation and verification, and...domains centered near White Sands Missile Range, New Mexico, where the Meteorological Sensor Array (MSA) will be located. The MSA will provide...observations and performing quality -control checks for the pre-forecast data assimilation period. 2. Run the WRE-N model to generate model forecast data

  3. A cluster-randomised quality improvement study to improve two inpatient stroke quality indicators.

    PubMed

    Williams, Linda; Daggett, Virginia; Slaven, James E; Yu, Zhangsheng; Sager, Danielle; Myers, Jennifer; Plue, Laurie; Woodward-Hagg, Heather; Damush, Teresa M

    2016-04-01

    Quality indicator collection and feedback improves stroke care. We sought to determine whether quality improvement training plus indicator feedback was more effective than indicator feedback alone in improving inpatient stroke indicators. We conducted a cluster-randomised quality improvement trial, randomising hospitals to quality improvement training plus indicator feedback versus indicator feedback alone to improve deep vein thrombosis (DVT) prophylaxis and dysphagia screening. Intervention sites received collaborative-based quality improvement training, external facilitation and indicator feedback. Control sites received only indicator feedback. We compared indicators pre-implementation (pre-I) to active implementation (active-I) and post-implementation (post-I) periods. We constructed mixed-effect logistic models of the two indicators with a random intercept for hospital effect, adjusting for patient, time, intervention and hospital variables. Patients at intervention sites (1147 admissions), had similar race, gender and National Institutes of Health Stroke Scale scores to control sites (1017 admissions). DVT prophylaxis improved more in intervention sites during active-I period (ratio of ORs 4.90, p<0.001), but did not differ in post-I period. Dysphagia screening improved similarly in both groups during active-I, but control sites improved more in post-I period (ratio of ORs 0.67, p=0.04). In logistic models, the intervention was independently positively associated with DVT performance during active-I period, and negatively associated with dysphagia performance post-I period. Quality improvement training was associated with early DVT improvement, but the effect was not sustained over time and was not seen with dysphagia screening. External quality improvement programmes may quickly boost performance but their effect may vary by indicator and may not sustain over time. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  4. The 'Alternative Quality Contract,' based on a global budget, lowered medical spending and improved quality.

    PubMed

    Song, Zirui; Safran, Dana Gelb; Landon, Bruce E; Landrum, Mary Beth; He, Yulei; Mechanic, Robert E; Day, Matthew P; Chernew, Michael E

    2012-08-01

    Seven provider organizations in Massachusetts entered the Blue Cross Blue Shield Alternative Quality Contract in 2009, followed by four more organizations in 2010. This contract, based on a global budget and pay-for-performance for achieving certain quality benchmarks, places providers at risk for excessive spending and rewards them for quality, similar to the new Pioneer Accountable Care Organizations in Medicare. We analyzed changes in spending and quality associated with the Alternative Quality Contract and found that the rate of increase in spending slowed compared to control groups, more so in the second year than in the first. Overall, participation in the contract over two years led to savings of 2.8 percent (1.9 percent in year 1 and 3.3 percent in year 2) compared to spending in nonparticipating groups. Savings were accounted for by lower prices achieved through shifting procedures, imaging, and tests to facilities with lower fees, as well as reduced utilization among some groups. Quality of care also improved compared to control organizations, with chronic care management, adult preventive care, and pediatric care within the contracting groups improving more in year 2 than in year 1. These results suggest that global budgets with pay-for-performance can begin to slow underlying growth in medical spending while improving quality of care.

  5. [Study of continuous quality improvement for clinical laboratory processes via the platform of Hospital Group].

    PubMed

    Song, Wenqi; Shen, Ying; Peng, Xiaoxia; Tian, Jian; Wang, Hui; Xu, Lili; Nie, Xiaolu; Ni, Xin

    2015-05-26

    The program of continuous quality improvement in clinical laboratory processes for complete blood count (CBC) was launched via the platform of Beijing Children's Hospital Group in order to improve the quality of pediatric clinical laboratories. Fifteen children's hospitals of Beijing Children's Hospital group were investigated using the method of Chinese adapted continuous quality improvement with PDCA (Plan-Do-Check-Action). The questionnaire survey and inter-laboratory comparison was conducted to find the existing problems, to analyze reasons, to set forth quality targets and to put them into practice. Then, targeted training was conducted to 15 children's hospitals and the second questionnaire survey, self examinations by the clinical laboratories was performed. At the same time, the Group's online internal quality control platform was established. Overall effects of the program were evaluated so that lay a foundation for the next stage of PDCA. Both quality of control system documents and CBC internal quality control scheme for all of clinical laboratories were improved through this program. In addition, standardization of performance verification was also improved, especially with the comparable verification rate of precision and internal laboratory results up to 100%. In terms of instrument calibration and mandatory diagnostic rates, only three out of the 15 hospitals (20%) failed to pass muster in 2014 from 46.67% (seven out of the 15 hospitals) in 2013. The abnormal data of intraday precision variance coefficients of the five CBC indicator parameters (WBC, RBC, Hb, Plt and Hct) of all the 15 laboratories accounted for 1.2% (2/165) in 2014, a marked decrease from 9.6% (14/145) in 2013. While the number of the hospitals using only one horizontal quality control object for daily quality control has dropped to three from five. The 15 hospitals organized a total of 263 times of training in 2014 from 101 times in 2013, up 160%. The quality improvement program for the clinical laboratories launched via the Hospital Group platform can promote the joint development of the pediatric clinical laboratory discipline of all the member hospitals with remarkable improvement results, and the experience is recommendable for further rollout.

  6. Testosterone Plus Low-Intensity Physical Training in Late Life Improves Functional Performance, Skeletal Muscle Mitochondrial Biogenesis, and Mitochondrial Quality Control in Male Mice

    PubMed Central

    Guo, Wen; Wong, Siu; Li, Michelle; Liang, Wentao; Liesa, Marc; Serra, Carlo; Jasuja, Ravi; Bartke, Andrzej; Kirkland, James L.; Shirihai, Orian; Bhasin, Shalender

    2012-01-01

    Testosterone supplementation increases muscle mass in older men but has not been shown to consistently improve physical function and activity. It has been hypothesized that physical exercise is required to induce the adaptations necessary for translation of testosterone-induced muscle mass gain into functional improvements. However, the effects of testosterone plus low intensity physical exercise training (T/PT) on functional performance and bioenergetics are unknown. In this pilot study, we tested the hypothesis that combined administration of T/PT would improve functional performance and bioenergetics in male mice late in life more than low-intensity physical training alone. 28-month old male mice were randomized to receive T/PT or vehicle plus physical training (V/PT) for 2 months. Compare to V/PT control, administration of T/PT was associated with improvements in muscle mass, grip strength, spontaneous physical movements, and respiratory activity. These changes were correlated with increased mitochondrial DNA copy number and expression of markers for mitochondrial biogenesis. Mice receiving T/PT also displayed increased expression of key elements for mitochondrial quality control, including markers for mitochondrial fission-and-fusion and mitophagy. Concurrently, mice receiving T/PT also displayed increased expression of markers for reduced tissue oxidative damage and improved muscle quality. Conclusion: Testosterone administered with low-intensity physical training improves grip strength, spontaneous movements, and respiratory activity. These functional improvements were associated with increased muscle mitochondrial biogenesis and improved mitochondrial quality control. PMID:23240002

  7. Internal quality control: best practice.

    PubMed

    Kinns, Helen; Pitkin, Sarah; Housley, David; Freedman, Danielle B

    2013-12-01

    There is a wide variation in laboratory practice with regard to implementation and review of internal quality control (IQC). A poor approach can lead to a spectrum of scenarios from validation of incorrect patient results to over investigation of falsely rejected analytical runs. This article will provide a practical approach for the routine clinical biochemistry laboratory to introduce an efficient quality control system that will optimise error detection and reduce the rate of false rejection. Each stage of the IQC system is considered, from selection of IQC material to selection of IQC rules, and finally the appropriate action to follow when a rejection signal has been obtained. The main objective of IQC is to ensure day-to-day consistency of an analytical process and thus help to determine whether patient results are reliable enough to be released. The required quality and assay performance varies between analytes as does the definition of a clinically significant error. Unfortunately many laboratories currently decide what is clinically significant at the troubleshooting stage. Assay-specific IQC systems will reduce the number of inappropriate sample-run rejections compared with the blanket use of one IQC rule. In practice, only three or four different IQC rules are required for the whole of the routine biochemistry repertoire as assays are assigned into groups based on performance. The tools to categorise performance and assign IQC rules based on that performance are presented. Although significant investment of time and education is required prior to implementation, laboratories have shown that such systems achieve considerable reductions in cost and labour.

  8. Development, optimization and validation of gas chromatographic fingerprinting of Brazilian commercial diesel fuel for quality control.

    PubMed

    dos Santos, Bruno César Diniz Brito; Flumignan, Danilo Luiz; de Oliveira, José Eduardo

    2012-10-01

    A three-step development, optimization and validation strategy is described for gas chromatography (GC) fingerprints of Brazilian commercial diesel fuel. A suitable GC-flame ionization detection (FID) system was selected to assay a complex matrix such as diesel. The next step was to improve acceptable chromatographic resolution with reduced analysis time, which is recommended for routine applications. Full three-level factorial designs were performed to improve flow rate, oven ramps, injection volume and split ratio in the GC system. Finally, several validation parameters were performed. The GC fingerprinting can be coupled with pattern recognition and multivariate regressions analyses to determine fuel quality and fuel physicochemical parameters. This strategy can also be applied to develop fingerprints for quality control of other fuel types.

  9. Factors associated with high-quality/low-cost hospital performance.

    PubMed

    Jiang, H Joanna; Friedman, Bernard; Begun, James W

    2006-01-01

    This study explores organizational and market characteristics associated with superior hospital performance in both quality and cost of care, using the Healthcare Cost and Utilization Project State Inpatient Databases for ten states in 1997 and 2001. After controlling for a variety of patient factors, we found that for-profit ownership, hospital competition, and the number of HMOs were positively associated with the likelihood of attaining high-quality/low-cost performance. Furthermore, we examined interactions between organizational and market characteristics and identified a number of significant interactions. For example, the positive likelihood associated with for-profit hospitals diminished in markets with high HMO penetration.

  10. Flight test results for several light, canard-configured airplanes

    NASA Technical Reports Server (NTRS)

    Brown, Philip W.

    1987-01-01

    Brief flight evaluations of two different, light, composite constructed, canard and winglet configured airplanes were performed to assess their handling qualities; one airplane was a single engine, pusher design and the other a twin engine, push-pull configuration. An emphasis was placed on the slow speed/high angle of attack region for both airplanes and on the engine-out regime for the twin. Mission suitability assessment included cockpit and control layout, ground and airborne handling qualities, and turbulence response. Very limited performance data was taken. Stall/spin tests and the effects of laminar flow loss on performance and handling qualities were assessed on an extended range, single engine pusher design.

  11. The quality of veterinary in-clinic and reference laboratory biochemical testing.

    PubMed

    Rishniw, Mark; Pion, Paul D; Maher, Tammy

    2012-03-01

    Although evaluation of biochemical analytes in blood is common in veterinary practice, studies assessing the global quality of veterinary in-clinic and reference laboratory testing have not been reported. The aim of this study was to assess the quality of biochemical testing in veterinary laboratories using results obtained from analyses of 3 levels of assayed quality control materials over 5 days. Quality was assessed by comparison of calculated total error with quality requirements, determination of sigma metrics, use of a quality goal index to determine factors contributing to poor performance, and agreement between in-clinic and reference laboratory mean results. The suitability of in-clinic and reference laboratory instruments for statistical quality control was determined using adaptations from the computerized program, EZRules3. Reference laboratories were able to achieve desirable quality requirements more frequently than in-clinic laboratories. Across all 3 materials, > 50% of in-clinic analyzers achieved a sigma metric ≥ 6.0 for measurement of 2 analytes, whereas > 50% of reference laboratory analyzers achieved a sigma metric ≥ 6.0 for measurement of 6 analytes. Expanded uncertainty of measurement and ± total allowable error resulted in the highest mean percentages of analytes demonstrating agreement between in-clinic and reference laboratories. Owing to marked variation in bias and coefficient of variation between analyzers of the same and different types, the percentages of analytes suitable for statistical quality control varied widely. These findings reflect the current state-of-the-art with regard to in-clinic and reference laboratory analyzer performance and provide a baseline for future evaluations of the quality of veterinary laboratory testing. © 2012 American Society for Veterinary Clinical Pathology.

  12. A Quality Assurance Initiative for Commercial-Scale Production in High-Throughput Cryopreservation of Blue Catfish Sperm

    PubMed Central

    Hu, E; Liao, T. W.; Tiersch, T. R.

    2013-01-01

    Cryopreservation of fish sperm has been studied for decades at a laboratory (research) scale. However, high-throughput cryopreservation of fish sperm has recently been developed to enable industrial-scale production. This study treated blue catfish (Ictalurus furcatus) sperm high-throughput cryopreservation as a manufacturing production line and initiated quality assurance plan development. The main objectives were to identify: 1) the main production quality characteristics; 2) the process features for quality assurance; 3) the internal quality characteristics and their specification designs; 4) the quality control and process capability evaluation methods, and 5) the directions for further improvements and applications. The essential product quality characteristics were identified as fertility-related characteristics. Specification design which established the tolerance levels according to demand and process constraints was performed based on these quality characteristics. Meanwhile, to ensure integrity throughout the process, internal quality characteristics (characteristics at each quality control point within process) that could affect fertility-related quality characteristics were defined with specifications. Due to the process feature of 100% inspection (quality inspection of every fish), a specific calculation method, use of cumulative sum (CUSUM) control charts, was applied to monitor each quality characteristic. An index of overall process evaluation, process capacity, was analyzed based on in-control process and the designed specifications, which further integrates the quality assurance plan. With the established quality assurance plan, the process could operate stably and quality of products would be reliable. PMID:23872356

  13. Performance and Usability of Various Robotic Arm Control Modes from Human Force Signals

    PubMed Central

    Mick, Sébastien; Cattaert, Daniel; Paclet, Florent; Oudeyer, Pierre-Yves; de Rugy, Aymar

    2017-01-01

    Elaborating an efficient and usable mapping between input commands and output movements is still a key challenge for the design of robotic arm prostheses. In order to address this issue, we present and compare three different control modes, by assessing them in terms of performance as well as general usability. Using an isometric force transducer as the command device, these modes convert the force input signal into either a position or a velocity vector, whose magnitude is linearly or quadratically related to force input magnitude. With the robotic arm from the open source 3D-printed Poppy Humanoid platform simulating a mobile prosthesis, an experiment was carried out with eighteen able-bodied subjects performing a 3-D target-reaching task using each of the three modes. The subjects were given questionnaires to evaluate the quality of their experience with each mode, providing an assessment of their global usability in the context of the task. According to performance metrics and questionnaire results, velocity control modes were found to perform better than position control mode in terms of accuracy and quality of control as well as user satisfaction and comfort. Subjects also seemed to favor quadratic velocity control over linear (proportional) velocity control, even if these two modes did not clearly distinguish from one another when it comes to performance and usability assessment. These results highlight the need to take into account user experience as one of the key criteria for the design of control modes intended to operate limb prostheses. PMID:29118699

  14. Measuring, managing and maximizing performance of mineral processing plants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bascur, O.A.; Kennedy, J.P.

    1995-12-31

    The implementation of continuous quality improvement is the confluence of Total Quality Management, People Empowerment, Performance Indicators and Information Engineering. The supporting information technologies allow a mineral processor to narrow the gap between management business objectives and the process control level. One of the most important contributors is the user friendliness and flexibility of the personal computer in a client/server environment. This synergistic combination when used for real time performance monitoring translates into production cost savings, improved communications and enhanced decision support. Other savings come from reduced time to collect data and perform tedious calculations, act quickly with fresh newmore » data, generate and validate data to be used by others. This paper presents an integrated view of plant management. The selection of the proper tools for continuous quality improvement are described. The process of selecting critical performance monitoring indices for improved plant performance are discussed. The importance of a well balanced technological improvement, personnel empowerment, total quality management and organizational assets are stressed.« less

  15. Effects of stick dynamics on helicopter flying qualities

    NASA Technical Reports Server (NTRS)

    Watson, Douglas C.; Schroeder, Jeffery A.

    1990-01-01

    An experiment that investigated the influence of typical helicopter force-feel system dynamics on roll-axis handling qualities was conducted in concurrent ground and inflight simulations. Variations in lateral control natural frequency and damping ratio, effected by changes in inertia and damping, were evaluated in a disturbance-rejection task. Pilot ratings indicated a preference for low-inertia feel systems, although measured performance was relatively constant over the range of stick characteristics. Force-sensing was compared with position sensing as the input to the control system. Force-sensing improved performance but did not improve pilot ratings. Overall, the results indicated that control-stick dynamics, at least within a reasonable range, did not have a significant effect on pilot-vehicle performance. However, the physical effort required to maintain a desired pilot/manipulator bandwidth became objectionable as the stick inertia increased beyond 5-7 lbm, which was reflected in the pilot ratings and comments.

  16. The comparison of perceived health-related quality of life between Australian children with severe specific language impairment to age and gender-matched peers.

    PubMed

    Nicola, Kristy; Watter, Pauline

    2018-02-14

    Children with specific language impairment often present with multiple comorbidities, which may adversely affect both participation in play and academic performance, potentially impacting a child's health-related quality of life. This study 1) explored the suitability of the Pediatric Quality of Life Inventory™ Version 4.0 Generic Core Scales (PedsQL™) for use with a typically developing Australian control group, and 2) compared the health-related quality of life between a control group and Australian children with severe specific language impairment. Health-related quality of life data collected as part of a broader study of 43 children with severe specific language impairment (males = 35, age range 5-16, mean age = 8.79+/- 2.92) enrolled at a special school were used to explore previously unreported findings. Typically developing gender and age matched (+/- 3 months) peers were recruited from local schools. The PedsQL™ child self-report and proxy-report were individually or interviewer-administered to the control group as required, and then compared to the group with specific language impairment. The PedsQL™ was reliable and feasible for use with the control group (N = 43, males = 35, age range = 5-16 years, mean age = 8.74+/- 2.94 years). Control group performance was as expected as per the manual. Parents of the control group scored their children significantly higher than did the children themselves on all scales except the emotional functioning scale. Both the control group children and their parents scored themselves significantly higher on all scales, compared to children with severe specific language impairment and their parents. The PedsQL™ was suitable for use with the control group. Further, the recruitment of a control group provided additional clarity on the extent a severe specific language impairment impacts on an Australian child's perceived health-related quality of life, compared to the manual cut-off scores. Severe specific language impairment significantly impacts negatively on the health-related quality of life of Australian children across all domains, particularly when compared to an age and gender-matched group of peers. These results warrant the inclusion of health-related quality of life evaluations in the assessment of these children along with a multidisciplinary approach.

  17. Oral physiology, nutrition and quality of life in diabetic patients associated or not with hypertension and beta-blockers therapy.

    PubMed

    Pereira, L J; Foureaux, R C; Pereira, C V; Alves, M C; Campos, C H; Rodrigues Garcia, R C M; Andrade, E F; Gonçalves, T M S V

    2016-07-01

    The relationship between type 2 diabetes oral physiology, nutritional intake and quality of life has not been fully elucidated. We assessed the impact of type 2 diabetes - exclusive or associated with hypertension with beta-blockers treatment - on oral physiology, mastication, nutrition and quality of life. This cross-sectional study was performed with 78 complete dentate subjects (15 natural teeth and six masticatory units minimum; without removable or fixed prostheses), divided into three groups: diabetics (DM) (n = 20; 45·4 ± 9·5 years), diabetics with hypertension and receiving beta-blockers treatment (DMH) (n = 19; 41·1 ± 5·1 years) and controls (n = 39; 44·5 ± 11·7 years) matched for gender, age and socioeconomic status. Blood glucose, masticatory performance, swallowing threshold, taste, food intake, stimulated and unstimulated salivary flow, pH and buffering capacity of saliva were assessed. Glycemia was higher in DM than in controls (P < 0·01). No differences were observed between DM and controls for nutrition and quality of life. Both stimulated and unstimulated salivary flow rate were lower in DMH (P < 0·01), which also presented the lowest number of teeth and masticatory units (P < 0·0001), and reduction in the number of chewing cycles (P < 0·01). Controls showed lower Decayed Missing Filled Teeth index (DMFT) scores in comparison with DMH (P = 0·021). Masticatory performance and saliva buffering capacity were similar among groups. Exclusive type 2 diabetes did not alter oral physiology, nutrition or quality of life. However, when hypertension and beta-blockers treatment were associated with diabetes, the salivary flow rate, chewing cycles and number of teeth decreased. © 2016 John Wiley & Sons Ltd.

  18. A Rotatable Quality Control Phantom for Evaluating the Performance of Flat Panel Detectors in Imaging Moving Objects.

    PubMed

    Haga, Yoshihiro; Chida, Koichi; Inaba, Yohei; Kaga, Yuji; Meguro, Taiichiro; Zuguchi, Masayuki

    2016-02-01

    As the use of diagnostic X-ray equipment with flat panel detectors (FPDs) has increased, so has the importance of proper management of FPD systems. To ensure quality control (QC) of FPD system, an easy method for evaluating FPD imaging performance for both stationary and moving objects is required. Until now, simple rotatable QC phantoms have not been available for the easy evaluation of the performance (spatial resolution and dynamic range) of FPD in imaging moving objects. We developed a QC phantom for this purpose. It consists of three thicknesses of copper and a rotatable test pattern of piano wires of various diameters. Initial tests confirmed its stable performance. Our moving phantom is very useful for QC of FPD images of moving objects because it enables visual evaluation of image performance (spatial resolution and dynamic range) easily.

  19. Scale Issues in Air Quality Modeling Policy Support

    EPA Science Inventory

    This study examines the issues relating to the use of regional photochemical air quality models for evaluating their performance in reproducing the spatio-temporal features embedded in the observations and for designing emission control strategies needed to achieve compliance wit...

  20. Guidebook: Quality Assurance/Quality Control Procedures for Submission of Data for the Land Disposal Restrictions (LDR) Program

    EPA Pesticide Factsheets

    This document explains how to generate data which characterizes the performance of hazardous waste treatment systems in terms of the composition of treated hazardous waste streams plus treatment system operation and design.

  1. [The comprehensive approach to ensure the quality of forensic medical examination of a cadaver].

    PubMed

    Mel'nikov, O V; Mal'tsev, A E; Petrov, S B; Petrov, B A

    2015-01-01

    The objective of the present work was to estimate the effectiveness of the comprehensive monitoring system designed to enhance the quality of forensic medical expertise for determining the cause of death in the hanging cases. It was shown that the practical application of the algorithmization and automated quality control system improves the effectiveness of forensic medical examination of the cadavers in the hanging cases. The system performs the control, directing, and teaching functions. Moreover, it allows to estimate the completeness of the examination of the cadaver.

  2. National continuous surveys on internal quality control for HbA1c in 306 clinical laboratories of China from 2012 to 2016: Continual improvement.

    PubMed

    Li, Tingting; Wang, Wei; Zhao, Haijian; He, Falin; Zhong, Kun; Yuan, Shuai; Wang, Zhiguo

    2017-09-01

    This study aimed to evaluate whether the quality performance of clinical laboratories in China has been greatly improved and whether Internal Quality Control (IQC) practice of HbA1c has also been changed since National Center for Clinical Laboratories (NCCL) of China organized laboratories to report IQC data for HbA1c in 2012. Internal Quality Control information of 306 External Quality Assessment (EQA) participant laboratories which kept reporting IQC data in February from 2012 to 2016 were collected by Web-based EQA system. Then percentages of laboratories meeting four different imprecision specifications for current coefficient of variations (CVs) of HbA1c measurements were calculated. Finally, we comprehensively analyzed analytical systems and IQC practice of HbA1c measurements. The current CVs of HbA1c tests have decreased significantly from 2012 to 2016. And percentages of laboratories meeting four imprecision specifications for CVs all showed the increasing tendency year by year. As for analytical system, 52.1% (159/306) laboratories changed their systems with the change in principle of assay. And many laboratories began to use cation exchange high-performance liquid chromatography (CE-HPLC) instead of Immunoturbidimetry, because CE-HPLC owed a lower intra-laboratory CVs. The data of IQC practice, such as IQC rules and frequency, also showed significant variability among years with overall tendency of meeting requirements. The imprecision performance of HbA1c tests has been improved in these 5 years with the change in IQC practice, but it is still disappointing in China. Therefore, laboratories should actively find existing problems and take action to promote performance of HbA1c measurements. © 2016 Wiley Periodicals, Inc.

  3. [Quality assurance of a virtual simulation software: application to IMAgo and SIMAgo (ISOgray)].

    PubMed

    Isambert, A; Beaudré, A; Ferreira, I; Lefkopoulos, D

    2007-06-01

    Virtual simulation process is often used to prepare three dimensional conformal radiation therapy treatments. As the quality of the treatment is widely dependent on this step, it is mandatory to perform extensive controls on this software before clinical use. The tests presented in this work have been carried out on the treatment planning system ISOgray (DOSIsoft), including the delineation module IMAgo and the virtual simulation module SIMAgo. According to our experience, the most relevant controls of international protocols have been selected. These tests mainly focused on measuring and delineation tools, virtual simulation functionalities, and have been performed with three phantoms: the Quasar Multi-Purpose Body Phantom, the Quasar MLC Beam Geometry Phantom (Modus Medical Devices Inc.) and a phantom developed at Hospital Tenon. No major issues have been identified while performing the tests. These controls have emphasized the necessity for the user to consider with a critical eye the results displayed by a virtual simulation software. The contrast of visualisation, the slice thickness, the calculation and display mode of 3D structures used by the software are many factors of uncertainties. A virtual simulation software quality assurance procedure has been written and applied on a set of CT images. Similar tests have to be performed periodically and at minimum at each change of major version.

  4. The Empirical Testing of a Musical Performance Assessment Paradigm

    ERIC Educational Resources Information Center

    Russell, Brian E.

    2010-01-01

    The purpose of this study was to test a hypothesized model of aurally perceived performer-controlled musical factors that influence assessments of performance quality. Previous research studies on musical performance constructs, musical achievement, musical expression, and scale construction were examined to identify the factors that influence…

  5. Preventive care quality of Medicare Accountable Care Organizations: Associations of organizational characteristics with performance

    PubMed Central

    Albright, Benjamin B.; Lewis, Valerie A.; Ross, Joseph S.; Colla, Carrie H.

    2015-01-01

    Background Accountable Care Organizations (ACOs) are a delivery and payment model aiming to coordinate care, control costs, and improve quality. Medicare ACOs are responsible for eight measures of preventive care quality. Objectives To create composite measures of preventive care quality and examine associations of ACO characteristics with performance. Design Cross-sectional study of Medicare Shared Savings Program and Pioneer participants. We linked quality performance to descriptive data from the National Survey of ACOs. We created composite measures using exploratory factor analysis, and used regression to assess associations with organizational characteristics. Results Of 252 eligible ACOs, 246 reported on preventive care quality, 177 of which completed the survey (response rate=72%). In their first year, ACOs lagged behind PPO performance on the majority of comparable measures. We identified two underlying factors among eight measures and created composites for each: disease prevention, driven by vaccines and cancer screenings, and wellness screening, driven by annual health screenings. Participation in the Advanced Payment Model, having fewer specialists, and having more Medicare ACO beneficiaries per primary care provider were associated with significantly better performance on both composites. Better performance on disease prevention was also associated with inclusion of a hospital, greater electronic health record capabilities, a larger primary care workforce, and fewer minority beneficiaries. Conclusions ACO preventive care quality performance is related to provider composition and benefitted by upfront investment. Vaccine and cancer screening quality performance is more dependent on organizational structure and characteristics than performance on annual wellness screenings, likely due to greater complexity in eligibility determination and service administration. PMID:26759974

  6. Preventive Care Quality of Medicare Accountable Care Organizations: Associations of Organizational Characteristics With Performance.

    PubMed

    Albright, Benjamin B; Lewis, Valerie A; Ross, Joseph S; Colla, Carrie H

    2016-03-01

    Accountable Care Organizations (ACOs) are a delivery and payment model aiming to coordinate care, control costs, and improve quality. Medicare ACOs are responsible for 8 measures of preventive care quality. To create composite measures of preventive care quality and examine associations of ACO characteristics with performance. This is a cross-sectional study of Medicare Shared Savings Program and Pioneer participants. We linked quality performance to descriptive data from the National Survey of ACOs. We created composite measures using exploratory factor analysis, and used regression to assess associations with organizational characteristics. Of 252 eligible ACOs, 246 reported on preventive care quality, 177 of which completed the survey (response rate=72%). In their first year, ACOs lagged behind PPO performance on the majority of comparable measures. We identified 2 underlying factors among 8 measures and created composites for each: disease prevention, driven by vaccines and cancer screenings, and wellness screening, driven by annual health screenings. Participation in the Advanced Payment Model, having fewer specialists, and having more Medicare ACO beneficiaries per primary care provider were associated with significantly better performance on both composites. Better performance on disease prevention was also associated with inclusion of a hospital, greater electronic health record capabilities, a larger primary care workforce, and fewer minority beneficiaries. ACO preventive care quality performance is related to provider composition and benefitted by upfront investment. Vaccine and cancer screening quality performance is more dependent on organizational structure and characteristics than performance on annual wellness screenings, likely due to greater complexity in eligibility determination and service administration.

  7. Performance evaluation of traffic sensing and control devices.

    DOT National Transportation Integrated Search

    2011-01-01

    High quality vehicle detection is essential to properly operate actuated phases at traffic signals and to facilitate effective : management of technician and engineering resources. INDOT operates over 2600 traffic signal controllers, approximately 20...

  8. Goals and strategies in the global control design of the OAJ Robotic Observatory

    NASA Astrophysics Data System (ADS)

    Yanes-Díaz, A.; Rueda-Teruel, S.; Antón, J. L.; Rueda-Teruel, F.; Moles, M.; Cenarro, A. J.; Marín-Franch, A.; Ederoclite, A.; Gruel, N.; Varela, J.; Cristóbal-Hornillos, D.; Chueca, S.; Díaz-Martín, M. C.; Guillén, L.; Luis-Simoes, R.; Maícas, N.; Lamadrid, J. L.; López-Sainz, A.; Hernández-Fuertes, J.; Valdivielso, L.; Mendes de Oliveira, C.; Penteado, P.; Schoenell, W.; Kanaan, A.

    2012-09-01

    There are many ways to solve the challenging problem of making a high performance robotic observatory from scratch. The Observatorio Astrofísico de Javalambre (OAJ) is a new astronomical facility located in the Sierra de Javalambre (Teruel, Spain) whose primary role will be to conduct all-sky astronomical surveys. The OAJ control system has been designed from a global point of view including astronomical subsystems as well as infrastructures and other facilities. Three main factors have been considered in the design of a global control system for the robotic OAJ: quality, reliability and efficiency. We propose CIA (Control Integrated Architecture) design and OEE (Overall Equipment Effectiveness) as a key performance indicator in order to improve operation processes, minimizing resources and obtaining high cost reduction whilst maintaining quality requirements. The OAJ subsystems considered for the control integrated architecture are the following: two wide-field telescopes and their instrumentation, active optics subsystems, facilities for sky quality monitoring (seeing, extinction, sky background, sky brightness, cloud distribution, meteorological station), domes and several infrastructure facilities such as water supply, glycol water, water treatment plant, air conditioning, compressed air, LN2 plant, illumination, surveillance, access control, fire suppression, electrical generators, electrical distribution, electrical consumption, communication network, Uninterruptible Power Supply and two main control rooms, one at the OAJ and the other remotely located in Teruel, 40km from the observatory, connected through a microwave radio-link. This paper presents the OAJ strategy in control design to achieve maximum quality efficiency for the observatory processes and operations, giving practical examples of our approach.

  9. An analysis of a candidate control algorithm for a ride quality augmentation system

    NASA Technical Reports Server (NTRS)

    Suikat, Reiner; Donaldson, Kent; Downing, David R.

    1987-01-01

    This paper presents a detailed analysis of a candidate algorithm for a ride quality augmentation system. The algorithm consists of a full-state feedback control law based on optimal control output weighting, estimators for angle of attack and sideslip, and a maneuvering algorithm. The control law is shown to perform well by both frequency and time domain analysis. The rms vertical acceleration is reduced by about 40 percent over the whole mission flight envelope. The estimators for the angle of attack and sideslip avoid the often inaccurate or costly direct measurement of those angles. The maneuvering algorithm will allow the augmented airplane to respond to pilot inputs. The design characteristics and performance are documented by the closed-loop eigenvalues; rms levels of vertical, lateral, and longitudinal acceleration; and representative time histories and frequency response.

  10. Multicapillary SDS-gel electrophoresis for the analysis of fluorescently labeled mAb preparations: a high throughput quality control process for the production of QuantiPlasma and PlasmaScan mAb libraries.

    PubMed

    Székely, Andrea; Szekrényes, Akos; Kerékgyártó, Márta; Balogh, Attila; Kádas, János; Lázár, József; Guttman, András; Kurucz, István; Takács, László

    2014-08-01

    Molecular heterogeneity of mAb preparations is the result of various co- and post-translational modifications and to contaminants related to the production process. Changes in molecular composition results in alterations of functional performance, therefore quality control and validation of therapeutic or diagnostic protein products is essential. A special case is the consistent production of mAb libraries (QuantiPlasma™ and PlasmaScan™) for proteome profiling, quality control of which represents a challenge because of high number of mAbs (>1000). Here, we devise a generally applicable multicapillary SDS-gel electrophoresis process for the analysis of fluorescently labeled mAb preparations for the high throughput quality control of mAbs of the QuantiPlasma™ and PlasmaScan™ libraries. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Standardized methods and quality control limits for agar and broth microdilution susceptibility testing of Mycoplasma pneumoniae, Mycoplasma hominis, and Ureaplasma urealyticum.

    PubMed

    Waites, Ken B; Duffy, Lynn B; Bébéar, Cécile M; Matlow, Anne; Talkington, Deborah F; Kenny, George E; Totten, Patricia A; Bade, Donald J; Zheng, Xiaotian; Davidson, Maureen K; Shortridge, Virginia D; Watts, Jeffrey L; Brown, Steven D

    2012-11-01

    An international multilaboratory collaborative study was conducted to develop standard media and consensus methods for the performance and quality control of antimicrobial susceptibility testing of Mycoplasma pneumoniae, Mycoplasma hominis, and Ureaplasma urealyticum using broth microdilution and agar dilution techniques. A reference strain from the American Type Culture Collection was designated for each species, which was to be used for quality control purposes. Repeat testing of replicate samples of each reference strain by participating laboratories utilizing both methods and different lots of media enabled a 3- to 4-dilution MIC range to be established for drugs in several different classes, including tetracyclines, macrolides, ketolides, lincosamides, and fluoroquinolones. This represents the first multilaboratory collaboration to standardize susceptibility testing methods and to designate quality control parameters to ensure accurate and reliable assay results for mycoplasmas and ureaplasmas that infect humans.

  12. Visual Perception Based Rate Control Algorithm for HEVC

    NASA Astrophysics Data System (ADS)

    Feng, Zeqi; Liu, PengYu; Jia, Kebin

    2018-01-01

    For HEVC, rate control is an indispensably important video coding technology to alleviate the contradiction between video quality and the limited encoding resources during video communication. However, the rate control benchmark algorithm of HEVC ignores subjective visual perception. For key focus regions, bit allocation of LCU is not ideal and subjective quality is unsatisfied. In this paper, a visual perception based rate control algorithm for HEVC is proposed. First bit allocation weight of LCU level is optimized based on the visual perception of luminance and motion to ameliorate video subjective quality. Then λ and QP are adjusted in combination with the bit allocation weight to improve rate distortion performance. Experimental results show that the proposed algorithm reduces average 0.5% BD-BR and maximum 1.09% BD-BR at no cost in bitrate accuracy compared with HEVC (HM15.0). The proposed algorithm devotes to improving video subjective quality under various video applications.

  13. X-31 high angle of attack control system performance

    NASA Technical Reports Server (NTRS)

    Huber, Peter; Seamount, Patricia

    1994-01-01

    The design goals for the X-31 flight control system were: (1) level 1 handling qualities during post-stall maneuvering (30 to 70 degrees angle-of-attack); (2) thrust vectoring to enhance performance across the flight envelope; and (3) adequate pitch-down authority at high angle-of-attack. Additional performance goals are discussed. A description of the flight control system is presented, highlighting flight control system features in the pitch and roll axes and X-31 thrust vectoring characteristics. The high angle-of-attack envelope clearance approach will be described, including a brief explanation of analysis techniques and tools. Also, problems encountered during envelope expansion will be discussed. This presentation emphasizes control system solutions to problems encountered in envelope expansion. An essentially 'care free' envelope was cleared for the close-in-combat demonstrator phase. High angle-of-attack flying qualities maneuvers are currently being flown and evaluated. These results are compared with pilot opinions expressed during the close-in-combat program and with results obtained from the F-18 HARV for identical maneuvers. The status and preliminary results of these tests are discussed.

  14. Towards a balanced performance measurement system in a public health care organization.

    PubMed

    Yuen, Peter P; Ng, Artie W

    2012-01-01

    This article attempts to devise an integrated performance measurement framework to assess the Hong Kong Hospital Authority (HA) management system by harnessing previous performance measurement systems. An integrated evaluative framework based on the balanced score card (BSC) was developed and applied using the case study method and longitudinal data to evaluate the HA's performance management system. The authors unveil evolving HA performance indicators (P1). Despite the HA staffs explicit quality emphasis, cost control remains the primary focus in their performance measurements. RESEARCH LHNITATIONS/IMPLICATIONS: Data used in this study are from secondary sources, disclosed mostly by HA staff. This study shows public sector staff often attach too much importance to cost control and easily measurable activities at the expense of quality and other less easily measurable attributes'. A balanced performance measurement system, linked to health targets, with a complementary budgeting process that supports pertinent resource allocation is yet to be implemented in Hong Kong's public hospitals.

  15. Piloted Evaluation of Modernized Limited Authority Control Laws in the NASA-Ames Vertical Motion Simulator (VMS)

    NASA Technical Reports Server (NTRS)

    Sahasrabudhe, Vineet; Melkers, Edgar; Faynberg, Alexander; Blanken, Chris L.

    2003-01-01

    The UH-60 BLACK HAWK was designed in the 1970s, when the US Army primarily operated during the day in good visual conditions. Subsequently, the introduction of night-vision goggles increased the BLACK HAWK'S mission effectiveness, but the accident rate also increased. The increased accident rate is strongly tied to increased pilot workload as a result of a degradation in visual cues. Over twenty years of research in helicopter flight control and handling qualities has shown that these degraded handling qualities can be recovered by modifying the response type of the helicopter in low speed flight. Sikorsky Aircraft Corporation initiated a project under the National Rotorcraft Technology Center (NRTC) to develop modern flight control laws while utilizing the existing partial authority Stability Augmentation System (SAS) of the BLACK HAWK. This effort resulted in a set of Modernized Control Laws (MCLAWS) that incorporate rate command and attitude command response types. Sikorsky and the US Army Aeroflightdynamics Directorate (AFDD) conducted a piloted simulation on the NASA-Ames Vertical h4otion Simulator, to assess potential handling qualities and to reduce the risk of subsequent implementation and flight test of these modern control laws on AFDD's EH-60L helicopter. The simulation showed that Attitude Command Attitude Hold control laws in pitch and roll improve handling qualities in the low speed flight regime. These improvements are consistent across a range of mission task elements and for both good and degraded visual environments. The MCLAWS perform better than the baseline UH-60A control laws in the presence of wind and turbulence. Finally, while the improved handling qualities in the pitch and roll axis allow the pilot to pay more attention to the vertical axis and hence altitude performance also improves, it is clear from pilot comments and altitude excursions that the addition of an Altitude Hold function would further reduce workload and improve overall handling qualities of the aircraft.

  16. Has compliance with CLIA requirements really improved quality in US clinical laboratories?

    PubMed

    Ehrmeyer, Sharon S; Laessig, Ronald H

    2004-08-02

    The Clinical Laboratory Improvement Amendments of 1988 (CLIA'88) mandate universal requirements for all U.S. clinical laboratory-testing sites. The intent of CLIA'88 is to ensure quality testing through a combination of minimum quality practices that incorporate total quality management concepts. These regulations do not contain established, objective indicators or measures to assess quality. However, there is an implicit assumption that compliance with traditionally accepted good laboratory practices--following manufacturers' directions, routinely analysing quality control materials, applying quality assurance principles, employing and assessing competent testing personnel, and participating in external quality assessment or proficiency testing (PT)--will result in improved test quality. The CLIA'88 regulations do include PT performance standards, which intentionally or unintentionally, define intra-laboratory performance. Passing PT has become a prime motivation for improving laboratory performance; it can also be used as an objective indicator to assess whether compliance to CLIA has improved intra-laboratory quality. Data from 1994 through 2002 indicate that the percentage of laboratories passing PT has increased. In addition to PT performance, subjective indicators of improved quality--frequency of inspection deficiencies, the number of government sanctions for non-compliance, and customer satisfaction--were evaluated. The results from these subjective indicators are more difficult to interpret but also seem to show improved quality in US clinical laboratories eleven years post-CLIA'88.

  17. 10 CFR 35.290 - Training for imaging and localization studies.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., at a minimum— (i) Classroom and laboratory training in the following areas— (A) Radiation physics and...) Performing quality control procedures on instruments used to determine the activity of dosages and performing...

  18. Simultaneous Determination of Ten Constituents in Chaiqin Qingning Capsule by High-performance Liquid Chromatography Coupled with Triple-quadrupole Mass Spectrometry

    PubMed Central

    Li, Ting Yu; Huo, Xiao Kui; Zheng, Lu; Wang, Chao; Cong, Hai Jian; Xiang, Ting; Zhang, Lin; Zhang, Bao Jing; Huang, Shan Shan; Wu, Bin; Li, Xin Yu

    2017-01-01

    Background: Chaiqin Qingning Capsule (CQQNC) was a prescription of Traditional Chinese Medicine with the effects of clearing away heat and removing toxin, harmonizing the exterior and interior, it was widely used in Asian, for example, China and Japan, different batches of the raws materials and different processing time may be the vital factor which raised a challenge to control the quality of the CQQNC. Experimental Methods: In this experiment, a high-performance liquid chromatography-mass spectrometry/MS (HPLC-MS/MS) method was developed to simultaneously determine ten bioactive components for the quality control of CQQNC. Chromatographic separation was achieved using an XBridge BEH C18 column (150 mm × 4.6 mm, 2.5 μm) with a mobile phase composed of 10 mm aqueous ammonium acetate and acetonitrile using a gradient elution in 20 min. This study was conducted by multiple reaction monitoring mode through electrospray ionization resource with a negative ionization mode. Results: The established method was validated with good performance of precision, accuracy, stability, and reproducibility and was utilized to simultaneously quantify ten constituents of CQQNC obtained from seven different batches. Conclusion: It is the first time to report the rapid and simultaneous analysis of the ten compounds in CQQNC by HPLC-MS/MS and apply to determine 10 constituents in 7 batches of CQQNC bought from drug store in china. This method could be considered as good quality criteria to control the quality of CQQNC. SUMMARY In this paper, a simple, specific, and rapid high-performance liquid chromatogram coupled with triple-quadrupole mass spectrometry method for simultaneous quantification of ten constituents in Chaiqin Qingning Capsule has been developed for the first time. This method could be considered as good quality criteria to control the quality of CQQNC. Abbreviations used: CHM: Chinese herbal medicine; TCM: Traditional Chinese Medicine; CQQNC: Triple-quadrupole mass spectrometry Chaiqin Qingning Capsules; HPLC–MS/MS: High liquid chromatography equipped with tandem mass spectrometry; ESI: Electrospray ionization; DP: Declustering potential; CE: Collision energy; RSD: Relative standard deviation; LOD: Limit of detection; LOQ: Limit of quantity. PMID:29200714

  19. Simultaneous Determination of Ten Constituents in Chaiqin Qingning Capsule by High-performance Liquid Chromatography Coupled with Triple-quadrupole Mass Spectrometry.

    PubMed

    Li, Ting Yu; Huo, Xiao Kui; Zheng, Lu; Wang, Chao; Cong, Hai Jian; Xiang, Ting; Zhang, Lin; Zhang, Bao Jing; Huang, Shan Shan; Wu, Bin; Li, Xin Yu

    2017-01-01

    Chaiqin Qingning Capsule (CQQNC) was a prescription of Traditional Chinese Medicine with the effects of clearing away heat and removing toxin, harmonizing the exterior and interior, it was widely used in Asian, for example, China and Japan, different batches of the raws materials and different processing time may be the vital factor which raised a challenge to control the quality of the CQQNC. In this experiment, a high-performance liquid chromatography-mass spectrometry/MS (HPLC-MS/MS) method was developed to simultaneously determine ten bioactive components for the quality control of CQQNC. Chromatographic separation was achieved using an XBridge BEH C18 column (150 mm × 4.6 mm, 2.5 μm) with a mobile phase composed of 10 mm aqueous ammonium acetate and acetonitrile using a gradient elution in 20 min. This study was conducted by multiple reaction monitoring mode through electrospray ionization resource with a negative ionization mode. The established method was validated with good performance of precision, accuracy, stability, and reproducibility and was utilized to simultaneously quantify ten constituents of CQQNC obtained from seven different batches. It is the first time to report the rapid and simultaneous analysis of the ten compounds in CQQNC by HPLC-MS/MS and apply to determine 10 constituents in 7 batches of CQQNC bought from drug store in china. This method could be considered as good quality criteria to control the quality of CQQNC. In this paper, a simple, specific, and rapid high-performance liquid chromatogram coupled with triple-quadrupole mass spectrometry method for simultaneous quantification of ten constituents in Chaiqin Qingning Capsule has been developed for the first time. This method could be considered as good quality criteria to control the quality of CQQNC. Abbreviations used: CHM: Chinese herbal medicine; TCM: Traditional Chinese Medicine; CQQNC: Triple-quadrupole mass spectrometry Chaiqin Qingning Capsules; HPLC-MS/MS: High liquid chromatography equipped with tandem mass spectrometry; ESI: Electrospray ionization; DP: Declustering potential; CE: Collision energy; RSD: Relative standard deviation; LOD: Limit of detection; LOQ: Limit of quantity.

  20. Application of miniaturized near-infrared spectroscopy for quality control of extemporaneous orodispersible films.

    PubMed

    Foo, Wen Chin; Widjaja, Effendi; Khong, Yuet Mei; Gokhale, Rajeev; Chan, Sui Yung

    2018-02-20

    Extemporaneous oral preparations are routinely compounded in the pharmacy due to a lack of suitable formulations for special populations. Such small-scale pharmacy preparations also present an avenue for individualized pharmacotherapy. Orodispersible films (ODF) have increasingly been evaluated as a suitable dosage form for extemporaneous oral preparations. Nevertheless, as with all other extemporaneous preparations, safety and quality remain a concern. Although the United States Pharmacopeia (USP) recommends analytical testing of compounded preparations for quality assurance, pharmaceutical assays are typically not routinely performed for such non-sterile pharmacy preparations, due to the complexity and high cost of conventional assay methods such as high performance liquid chromatography (HPLC). Spectroscopic methods including Raman, infrared and near-infrared spectroscopy have been successfully applied as quality control tools in the industry. The state-of-art benchtop spectrometers used in those studies have the advantage of superior resolution and performance, but are not suitable for use in a small-scale pharmacy setting. In this study, we investigated the application of a miniaturized near infrared (NIR) spectrometer as a quality control tool for identification and quantification of drug content in extemporaneous ODFs. Miniaturized near infrared (NIR) spectroscopy is suitable for small-scale pharmacy applications in view of its small size, portability, simple user interface, rapid measurement and real-time prediction results. Nevertheless, the challenge with miniaturized NIR spectroscopy is its lower resolution compared to state-of-art benchtop equipment. We have successfully developed NIR spectroscopy calibration models for identification of ODFs containing five different drugs, and quantification of drug content in ODFs containing 2-10mg ondansetron (OND). The qualitative model for drug identification produced 100% prediction accuracy. The quantitative model to predict OND drug content in ODFs was divided into two calibrations for improved accuracy: Calibration I and II covered the 2-4mg and 4-10mg ranges respectively. Validation was performed for method accuracy, linearity and precision. In conclusion, this study demonstrates the feasibility of miniaturized NIR spectroscopy as a quality control tool for small-scale, pharmacy preparations. Due to its non-destructive nature, every dosage unit can be tested thus affording positive impact on patient safety. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Integrated Neural Flight and Propulsion Control System

    NASA Technical Reports Server (NTRS)

    Kaneshige, John; Gundy-Burlet, Karen; Norvig, Peter (Technical Monitor)

    2001-01-01

    This paper describes an integrated neural flight and propulsion control system. which uses a neural network based approach for applying alternate sources of control power in the presence of damage or failures. Under normal operating conditions, the system utilizes conventional flight control surfaces. Neural networks are used to provide consistent handling qualities across flight conditions and for different aircraft configurations. Under damage or failure conditions, the system may utilize unconventional flight control surface allocations, along with integrated propulsion control, when additional control power is necessary for achieving desired flight control performance. In this case, neural networks are used to adapt to changes in aircraft dynamics and control allocation schemes. Of significant importance here is the fact that this system can operate without emergency or backup flight control mode operations. An additional advantage is that this system can utilize, but does not require, fault detection and isolation information or explicit parameter identification. Piloted simulation studies were performed on a commercial transport aircraft simulator. Subjects included both NASA test pilots and commercial airline crews. Results demonstrate the potential for improving handing qualities and significantly increasing survivability rates under various simulated failure conditions.

  2. 10 CFR 63.142 - Quality assurance criteria.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...) Design control. (1) DOE shall establish measures to assure that applicable regulatory requirements and... control design interfaces and for coordination among participating design organizations. These measures... control measures must provide for verifying or checking the adequacy of design, such as by the performance...

  3. 10 CFR 63.142 - Quality assurance criteria.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...) Design control. (1) DOE shall establish measures to assure that applicable regulatory requirements and... control design interfaces and for coordination among participating design organizations. These measures... control measures must provide for verifying or checking the adequacy of design, such as by the performance...

  4. 10 CFR 63.142 - Quality assurance criteria.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...) Design control. (1) DOE shall establish measures to assure that applicable regulatory requirements and... control design interfaces and for coordination among participating design organizations. These measures... control measures must provide for verifying or checking the adequacy of design, such as by the performance...

  5. 10 CFR 63.142 - Quality assurance criteria.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...) Design control. (1) DOE shall establish measures to assure that applicable regulatory requirements and... control design interfaces and for coordination among participating design organizations. These measures... control measures must provide for verifying or checking the adequacy of design, such as by the performance...

  6. Effect of pay for performance to improve quality of maternal and child care in low- and middle-income countries: a systematic review.

    PubMed

    Das, Ashis; Gopalan, Saji S; Chandramohan, Daniel

    2016-04-14

    Pay for Performance (P4P) mechanisms to health facilities and providers are currently being tested in several low- and middle-income countries (LMIC) to improve maternal and child health (MCH). This paper reviews the existing evidence on the effect of P4P program on quality of MCH care in LMICs. A systematic review of literature was conducted according to a registered protocol. MEDLINE, Web of Science, and Embase were searched using the key words maternal care, quality of care, ante natal care, emergency obstetric and neonatal care (EmONC) and child care. Of 4535 records retrieved, only eight papers met the inclusion criteria. Primary outcome of interest was quality of MCH disaggregated into structural quality, process quality and outcomes. Risk of bias across studies was assessed through a customized quality checklist. There were four controlled before after intervention studies, three cluster randomized controlled trials and one case control with post-intervention comparison of P4P programs for MCH care in Burundi, Democratic Republic of Congo, Egypt, the Philippines, and Rwanda. There is some evidence of positive effect of P4P only on process quality of MCH. The effect of P4P on delivery, EmONC, post natal care and under-five child care were not evaluated in these studies. There is weak evidence for P4P's positive effect on maternal and neonatal health outcomes and out-of-pocket expenses. P4P program had a few negative effects on structural quality. P4P is effective to improve process quality of ante natal care. However, further research is needed to understand P4P's impact on MCH and their causal pathways in LMICs. PROSPERO registration number CRD42014013077 .

  7. Automated daily quality control analysis for mammography in a multi-unit imaging center.

    PubMed

    Sundell, Veli-Matti; Mäkelä, Teemu; Meaney, Alexander; Kaasalainen, Touko; Savolainen, Sauli

    2018-01-01

    Background The high requirements for mammography image quality necessitate a systematic quality assurance process. Digital imaging allows automation of the image quality analysis, which can potentially improve repeatability and objectivity compared to a visual evaluation made by the users. Purpose To develop an automatic image quality analysis software for daily mammography quality control in a multi-unit imaging center. Material and Methods An automated image quality analysis software using the discrete wavelet transform and multiresolution analysis was developed for the American College of Radiology accreditation phantom. The software was validated by analyzing 60 randomly selected phantom images from six mammography systems and 20 phantom images with different dose levels from one mammography system. The results were compared to a visual analysis made by four reviewers. Additionally, long-term image quality trends of a full-field digital mammography system and a computed radiography mammography system were investigated. Results The automated software produced feature detection levels comparable to visual analysis. The agreement was good in the case of fibers, while the software detected somewhat more microcalcifications and characteristic masses. Long-term follow-up via a quality assurance web portal demonstrated the feasibility of using the software for monitoring the performance of mammography systems in a multi-unit imaging center. Conclusion Automated image quality analysis enables monitoring the performance of digital mammography systems in an efficient, centralized manner.

  8. The ‘Alternative Quality Contract’ in Massachusetts, Based on Global Budgets, Lowered Medical Spending and Improved Quality

    PubMed Central

    Song, Zirui; Safran, Dana Gelb; Landon, Bruce E.; Landrum, Mary Beth; He, Yulei; Mechanic, Robert E.; Day, Matthew P.; Chernew, Michael E.

    2012-01-01

    Seven provider organizations in Massachusetts entered the Blue Cross Blue Shield Alternative Quality Contract in 2009, followed by four more organizations in 2010. This contract, based on a global budget and pay-for-performance for achieving certain quality benchmarks, places providers at risk for excessive spending and rewards them for quality, similar to the new Pioneer Accountable Care Organizations in Medicare. We analyzed changes in spending and quality associated with the Alternative Quality Contract and found that the rate of increase in spending slowed compared to control groups. Overall, participation in the contract over two years led to a savings of 3.3% (1.9% in year-1, 3.3% in year-2) compared to spending in groups not participating in the contract. The savings were even higher for groups whose previous experience had been only in fee-for-service contracting. Such groups’ quarterly savings over two years averaged 8.2% (6.3% in year-1, 9.9% in year-2). Quality of care also improved within organizations participating in the Alternative Quality Contract compared to control organizations in both years. Chronic care management, adult preventive care, and pediatric care improved from year 1 to year 2 within the contracting groups. These results suggest that global budgets coupled with pay-for-performance can begin to slow the underlying growth in medical spending while improving quality. PMID:22786651

  9. Effects of a computerized cardiac teletriage decision support system on nurse performance: results of a controlled human factors experiment using a mid-fidelity prototype.

    PubMed

    Somoza, Kirsten Carroll; Momtahan, Kathryn; Lindgaard, Gitte

    2007-01-01

    A gap exists in cardiac care between known best practices and the actual level of care administered. To help bridge this gap, a proof of concept interface for a PDA-based decision support system (DSS) was designed for cardiac care nurses engaged in teletriage. This interface was developed through a user-centered design process. Quality of assessment, quality of recommendations, and number of questions asked were measured. Cardiac floor nurses' assessment quality performance, but not their recommendation quality performance, improved with the DSS. Nurses asked more questions with the DSS than without it, and these additional questions were predominantly classifiable as essential or beneficial to a good assessment. The average participant satisfaction score with the DSS was above neutral.

  10. Implementation research to improve quality of maternal and newborn health care, Malawi.

    PubMed

    Brenner, Stephan; Wilhelm, Danielle; Lohmann, Julia; Kambala, Christabel; Chinkhumba, Jobiba; Muula, Adamson S; De Allegri, Manuela

    2017-07-01

    To evaluate the impact of a performance-based financing scheme on maternal and neonatal health service quality in Malawi. We conducted a non-randomized controlled before and after study to evaluate the effects of district- and facility-level performance incentives for health workers and management teams. We assessed changes in the facilities' essential drug stocks, equipment maintenance and clinical obstetric care processes. Difference-in-difference regression models were used to analyse effects of the scheme on adherence to obstetric care treatment protocols and provision of essential drugs, supplies and equipment. We observed 33 health facilities, 23 intervention facilities and 10 control facilities and 401 pregnant women across four districts. The scheme improved the availability of both functional equipment and essential drug stocks in the intervention facilities. We observed positive effects in respect to drug procurement and clinical care activities at non-intervention facilities, likely in response to improved district management performance. Birth assistants' adherence to clinical protocols improved across all studied facilities as district health managers supervised and coached clinical staff more actively. Despite nation-wide stock-outs and extreme health worker shortages, facilities in the study districts managed to improve maternal and neonatal health service quality by overcoming bottlenecks related to supply procurement, equipment maintenance and clinical performance. To strengthen and reform health management structures, performance-based financing may be a promising approach to sustainable improvements in quality of health care.

  11. Radiation protection program for early detection of breast cancer in a mammography facility

    NASA Astrophysics Data System (ADS)

    Villagomez Casimiro, Mariana; Ruiz Trejo, Cesar; Espejo Fonseca, Ruby

    2014-11-01

    Mammography is the best tool for early detection of Breast Cancer. In this diagnostic radiology modality it is necessary to establish the criteria to ensure the proper use and operation of the equipment used to obtain mammographic images in order to contribute to the safe use of ionizing radiation. The aim of the work was to implement at FUCAM-AC the radiation protection program which must be established for patients and radiation workers according to Mexican standards [1-4]. To achieve this goal, radiation protection and quality control manuals were elaborated [5]. Furthermore, a quality control program (QCP) in the mammography systems (analog/digital), darkroom included, has been implemented. Daily sensitometry, non-variability of the image quality, visualizing artifacts, revision of the equipment mechanical stability, compression force and analysis of repetition studies are some of the QCP routine tests that must be performed by radiological technicians of this institution as a set of actions to ensure the protection of patients. Image quality and patients dose assessment were performed on 4 analog equipment installed in 2 mobile units. In relation to dose assessment, all equipment passed the acceptance criteria (<3 mGy per projection). The image quality test showed that most images (70%)- presented artifacts. A brief summary of the results of quality control tests applied to the equipment and film processor are presented. To maintain an adequate level of quality and safety at FUCAM-AC is necessary that the proposed radiation protection program in this work is applied.

  12. High-field open versus short-bore magnetic resonance imaging of the spine: a randomized controlled comparison of image quality.

    PubMed

    Enders, Judith; Rief, Matthias; Zimmermann, Elke; Asbach, Patrick; Diederichs, Gerd; Wetz, Christoph; Siebert, Eberhard; Wagner, Moritz; Hamm, Bernd; Dewey, Marc

    2013-01-01

    The purpose of the present study was to compare the image quality of spinal magnetic resonance (MR) imaging performed on a high-field horizontal open versus a short-bore MR scanner in a randomized controlled study setup. Altogether, 93 (80% women, mean age 53) consecutive patients underwent spine imaging after random assignement to a 1-T horizontal open MR scanner with a vertical magnetic field or a 1.5-T short-bore MR scanner. This patient subset was part of a larger cohort. Image quality was assessed by determining qualitative parameters, signal-to-noise (SNR) and contrast-to-noise ratios (CNR), and quantitative contour sharpness. The image quality parameters were higher for short-bore MR imaging. Regarding all sequences, the relative differences were 39% for the mean overall qualitative image quality, 53% for the mean SNR values, and 34-37% for the quantitative contour sharpness (P<0.0001). The CNR values were also higher for images obtained with the short-bore MR scanner. No sequence was of very poor (nondiagnostic) image quality. Scanning times were significantly longer for examinations performed on the open MR scanner (mean: 32±22 min versus 20±9 min; P<0.0001). In this randomized controlled comparison of spinal MR imaging with an open versus a short-bore scanner, short-bore MR imaging revealed considerably higher image quality with shorter scanning times. ClinicalTrials.gov NCT00715806.

  13. High-Field Open versus Short-Bore Magnetic Resonance Imaging of the Spine: A Randomized Controlled Comparison of Image Quality

    PubMed Central

    Zimmermann, Elke; Asbach, Patrick; Diederichs, Gerd; Wetz, Christoph; Siebert, Eberhard; Wagner, Moritz; Hamm, Bernd; Dewey, Marc

    2013-01-01

    Background The purpose of the present study was to compare the image quality of spinal magnetic resonance (MR) imaging performed on a high-field horizontal open versus a short-bore MR scanner in a randomized controlled study setup. Methods Altogether, 93 (80% women, mean age 53) consecutive patients underwent spine imaging after random assignement to a 1-T horizontal open MR scanner with a vertical magnetic field or a 1.5-T short-bore MR scanner. This patient subset was part of a larger cohort. Image quality was assessed by determining qualitative parameters, signal-to-noise (SNR) and contrast-to-noise ratios (CNR), and quantitative contour sharpness. Results The image quality parameters were higher for short-bore MR imaging. Regarding all sequences, the relative differences were 39% for the mean overall qualitative image quality, 53% for the mean SNR values, and 34–37% for the quantitative contour sharpness (P<0.0001). The CNR values were also higher for images obtained with the short-bore MR scanner. No sequence was of very poor (nondiagnostic) image quality. Scanning times were significantly longer for examinations performed on the open MR scanner (mean: 32±22 min versus 20±9 min; P<0.0001). Conclusions In this randomized controlled comparison of spinal MR imaging with an open versus a short-bore scanner, short-bore MR imaging revealed considerably higher image quality with shorter scanning times. Trial Registration ClinicalTrials.gov NCT00715806 PMID:24391767

  14. Improved quality monitoring of multi-center acupuncture clinical trials in China

    PubMed Central

    2009-01-01

    Background In 2007, the Chinese Science Division of the State Administration of Traditional Chinese Medicine(TCM) convened a special conference to discuss quality control for TCM clinical research. Control and assurance standards were established to guarantee the quality of clinical research. This paper provides practical guidelines for implementing strict and reproducible quality control for acupuncture randomized controlled trials (RCTs). Methods A standard quality control program (QCP) was established to monitor the quality of acupuncture trials. Case report forms were designed; qualified investigators, study personnel and data management personnel were trained. Monitors, who were directly appointed by the project leader, completed the quality control programs. They guaranteed data accuracy and prevented or detected protocol violations. Clinical centers and clinicians were audited, the randomization system of the centers was inspected, and the treatment processes were audited as well. In addition, the case report forms were reviewed for completeness and internal consistency, the eligibility and validity of the patients in the study was verified, and data was monitored for compliance and accuracy. Results and discussion The monitors complete their reports and submit it to quality assurance and the sponsors. Recommendations and suggestions are made for improving performance. By holding regular meetings to discuss improvements in monitoring standards, the monitors can improve quality and efficiency. Conclusions Supplementing and improving the existed guidelines for quality monitoring will ensure that large multi-centre acupuncture clinical trials will be considered as valid and scientifically stringent as pharmaceutical clinical trials. It will also develop academic excellence and further promote the international recognition of acupuncture. PMID:20035630

  15. Quality control for the first large areas of triple-GEM chambers for the CMS endcaps

    NASA Astrophysics Data System (ADS)

    Abbaneo, D.; Abbas, M.; Abbrescia, M.; Abi Akl, M.; Aboamer, O.; Acosta, D.; Ahmad, A.; Ahmed, W.; Aleksandrov, A.; Altieri, P.; Asawatangtrakuldee, C.; Aspell, P.; Assran, Y.; Awan, I.; Bally, S.; Ban, Y.; Banerjee, S.; Barashko, V.; Barria, P.; Bencze, G.; Beni, N.; Benussi, L.; Bhopatkar, V.; Bianco, S.; Bos, J.; Bouhali, O.; Braghieri, A.; Braibant, S.; Buontempo, S.; Calabria, C.; Caponero, M.; Caputo, C.; Cassese, F.; Castaneda, A.; Cauwenbergh, S.; Cavallo, F. R.; Celik, A.; Choi, M.; Choi, S.; Christiansen, J.; Cimmino, A.; Colafranceschi, S.; Colaleo, A.; Conde Garcia, A.; Czellar, S.; Dabrowski, M. M.; De Lentdecker, G.; De Oliveira, R.; de Robertis, G.; Dildick, S.; Dorney, B.; Endroczi, G.; Errico, F.; Fenyvesi, A.; Ferry, S.; Furic, I.; Giacomelli, P.; Gilmore, J.; Golovtsov, V.; Guiducci, L.; Guilloux, F.; Gutierrez, A.; Hadjiiska, R. M.; Hauser, J.; Hoepfner, K.; Hohlmann, M.; Hoorani, H.; Iaydjiev, P.; Jeng, Y. G.; Kamon, T.; Karchin, P.; Korytov, A.; Krutelyov, S.; Kumar, A.; Kim, H.; Lee, J.; Lenzi, T.; Litov, L.; Loddo, F.; Madorsky, A.; Maerschalk, T.; Maggi, M.; Magnani, A.; Mal, P. K.; Mandal, K.; Marchioro, A.; Marinov, A.; Majumdar, N.; Merlin, J. A.; Mitselmakher, G.; Mohanty, A. K.; Mohapatra, A.; Molnar, J.; Muhammad, S.; Mukhopadhyay, S.; Naimuddin, M.; Nuzzo, S.; Oliveri, E.; Pant, L. M.; Paolucci, P.; Park, I.; Passeggio, G.; Pavlov, B.; Philipps, B.; Piccolo, D.; Postema, H.; Puig Baranac, A.; Radi, A.; Radogna, R.; Raffone, G.; Ranieri, A.; Rashevski, G.; Riccardi, C.; Rodozov, M.; Rodrigues, A.; Ropelewski, L.; RoyChowdhury, S.; Ryu, G.; Ryu, M. S.; Safonov, A.; Salva, S.; Saviano, G.; Sharma, A.; Sharma, A.; Sharma, R.; Shah, A. H.; Shopova, M.; Sturdy, J.; Sultanov, G.; Swain, S. K.; Szillasi, Z.; Talvitie, J.; Tatarinov, A.; Tuuva, T.; Tytgat, M.; Vai, I.; Van Stenis, M.; Venditti, R.; Verhagen, E.; Verwilligen, P.; Vitulo, P.; Volkov, S.; Vorobyev, A.; Wang, D.; Wang, M.; Yang, U.; Yang, Y.; Yonamine, R.; Zaganidis, N.; Zenoni, F.; Zhang, A.

    2018-02-01

    The CMS Collaboration plans to equip the very forward muon system with triple-GEM detectors that can withstand the environment of the High-Luminosity LHC. This project is at the final stages of R&D and moving to production. An unprecedented large area of several 100 m2 are to be instrumented with GEM detectors which will be produced in six different sites around the world. A common construction and quality control procedure is required to ensure the performance of each detector. The quality control steps will include optical inspection, cleaning and baking of all materials and parts used to build the detector, leakage current tests of the GEM foils, high voltage tests, gas leak tests of the chambers and monitoring pressure drop vs. time, gain calibration to know the optimal operation region of the detector, gain uniformity tests, and studying the efficiency, noise and tracking performance of the detectors in a cosmic stand using scintillators.

  16. Multi-component determination and chemometric analysis of Paris polyphylla by ultra high performance liquid chromatography with photodiode array detection.

    PubMed

    Chen, Pei; Jin, Hong-Yu; Sun, Lei; Ma, Shuang-Cheng

    2016-09-01

    Multi-source analysis of traditional Chinese medicine is key to ensuring its safety and efficacy. Compared with traditional experimental differentiation, chemometric analysis is a simpler strategy to identify traditional Chinese medicines. Multi-component analysis plays an increasingly vital role in the quality control of traditional Chinese medicines. A novel strategy, based on chemometric analysis and quantitative analysis of multiple components, was proposed to easily and effectively control the quality of traditional Chinese medicines such as Chonglou. Ultra high performance liquid chromatography was more convenient and efficient. Five species of Chonglou were distinguished by chemometric analysis and nine saponins, including Chonglou saponins I, II, V, VI, VII, D, and H, as well as dioscin and gracillin, were determined in 18 min. The method is feasible and credible, and enables to improve quality control of traditional Chinese medicines and natural products. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Human High Temperature Requirement Serine Protease A1 (HTRA1) Degrades Tau Protein Aggregates*

    PubMed Central

    Tennstaedt, Annette; Pöpsel, Simon; Truebestein, Linda; Hauske, Patrick; Brockmann, Anke; Schmidt, Nina; Irle, Inga; Sacca, Barbara; Niemeyer, Christof M.; Brandt, Roland; Ksiezak-Reding, Hanna; Tirniceriu, Anca Laura; Egensperger, Rupert; Baldi, Alfonso; Dehmelt, Leif; Kaiser, Markus; Huber, Robert; Clausen, Tim; Ehrmann, Michael

    2012-01-01

    Protective proteases are key elements of protein quality control pathways that are up-regulated, for example, under various protein folding stresses. These proteases are employed to prevent the accumulation and aggregation of misfolded proteins that can impose severe damage to cells. The high temperature requirement A (HtrA) family of serine proteases has evolved to perform important aspects of ATP-independent protein quality control. So far, however, no HtrA protease is known that degrades protein aggregates. We show here that human HTRA1 degrades aggregated and fibrillar tau, a protein that is critically involved in various neurological disorders. Neuronal cells and patient brains accumulate less tau, neurofibrillary tangles, and neuritic plaques, respectively, when HTRA1 is expressed at elevated levels. Furthermore, HTRA1 mRNA and HTRA1 activity are up-regulated in response to elevated tau concentrations. These data suggest that HTRA1 is performing regulated proteolysis during protein quality control, the implications of which are discussed. PMID:22535953

  18. Develop nondestructive rapid pavement quality assurance/quality control evaluation test methods and supporting technology : project summary.

    DOT National Transportation Integrated Search

    2017-01-01

    The findings from the proof of concept with mechanics-based models for flexible base suggest additional validation work should be performed, draft construction specification frameworks should be developed, and work extending the technology to stabili...

  19. Portland cement concrete pavement review of QC/QA data 2000 through 2009.

    DOT National Transportation Integrated Search

    2011-04-01

    This report analyzes the Quality Control/Quality Assurance (QC/QA) data for Portland cement concrete pavement : (PCCP) awarded in the years 2000 through 2009. Analysis of the overall performance of the projects is accomplished by : reviewing the Calc...

  20. Develop nondestructive rapid pavement quality Assurance/quality control evaluation test methods and supporting technology : project summary.

    DOT National Transportation Integrated Search

    2017-01-01

    The findings from the proof of concept with mechanics-based models for flexible base suggest additional validation work should be performed, draft construction specification frameworks should be developed, and work extending the technology to stabili...

  1. The importance of quality control in validating concentrations ...

    EPA Pesticide Factsheets

    A national-scale survey of 247 contaminants of emerging concern (CECs), including organic and inorganic chemical compounds, and microbial contaminants, was conducted in source and treated drinking water samples from 25 treatment plants across the United States. Multiple methods were used to determine these CECs, including six analytical methods to measure 174 pharmaceuticals, personal care products, and pesticides. A three-component quality assurance/quality control (QA/QC) program was designed for the subset of 174 CECs which allowed us to assess and compare performances of the methods used. The three components included: 1) a common field QA/QC protocol and sample design, 2) individual investigator-developed method-specific QA/QC protocols, and 3) a suite of 46 method comparison analytes that were determined in two or more analytical methods. Overall method performance for the 174 organic chemical CECs was assessed by comparing spiked recoveries in reagent, source, and treated water over a two-year period. In addition to the 247 CECs reported in the larger drinking water study, another 48 pharmaceutical compounds measured did not consistently meet predetermined quality standards. Methodologies that did not seem suitable for these analytes are overviewed. The need to exclude analytes based on method performance demonstrates the importance of additional QA/QC protocols. This paper compares the method performance of six analytical methods used to measure 174 emer

  2. Statistical process control: separating signal from noise in emergency department operations.

    PubMed

    Pimentel, Laura; Barrueto, Fermin

    2015-05-01

    Statistical process control (SPC) is a visually appealing and statistically rigorous methodology very suitable to the analysis of emergency department (ED) operations. We demonstrate that the control chart is the primary tool of SPC; it is constructed by plotting data measuring the key quality indicators of operational processes in rationally ordered subgroups such as units of time. Control limits are calculated using formulas reflecting the variation in the data points from one another and from the mean. SPC allows managers to determine whether operational processes are controlled and predictable. We review why the moving range chart is most appropriate for use in the complex ED milieu, how to apply SPC to ED operations, and how to determine when performance improvement is needed. SPC is an excellent tool for operational analysis and quality improvement for these reasons: 1) control charts make large data sets intuitively coherent by integrating statistical and visual descriptions; 2) SPC provides analysis of process stability and capability rather than simple comparison with a benchmark; 3) SPC allows distinction between special cause variation (signal), indicating an unstable process requiring action, and common cause variation (noise), reflecting a stable process; and 4) SPC keeps the focus of quality improvement on process rather than individual performance. Because data have no meaning apart from their context, and every process generates information that can be used to improve it, we contend that SPC should be seriously considered for driving quality improvement in emergency medicine. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. [Impact of the entry age and veterinary care on the health and performance of veal calves. II. Blood values, performance and carcass quality].

    PubMed

    Bähler, C; Tschuor, A; Schüpbach-Regula, G

    2016-07-01

    The objective of this field study was to investigate the impact of the entry age and of veterinary care on blood values, performance and carcass quality of veal calves in Switzerland. From July 2012 until May 2013 a total of 316 young calves (aged ø 10.8 days), 425 market calves (aged ø 39.5 days), and 65 old calves (aged ø 61.5 days) were observed during the production cycle. As control calves 9'019 veal calves fattened at the same time as the market calves were available. At time of entry the average hemoglobin value of 88.2 g/l in market calves was significantly (p < 0.001) lower than in young (96.2 g/l), old (95.0 g/l) and control calves (95.0 g/l). At time of slaughter the hemoglobin of control calves was 101.2 g/l and significantly (p < 0.001) lower than in young (129.6 g/l) and market calves (131.6 g/l). The average daily weight gain reached 1.21 kg in young calves, 1.28 kg in market calves, 1.29 kg in old calves and 1.30 kg in control calves. The premature slaughter rate was 3.4% in control calves, 8.1% young (p < 0.001), 3.4% in commercial and 0% in old calves (p = 0.17). The percentage of the favorite carcass quality was 53.8% in control calves and differed significantly (p < 0.001) from young (43.5%) and market calves (42.8%), but not from old calves (50.8%, p = 0.9). The carcass color with the average photometric L-value of 41.5 in young and 41.6 in market calves differed significantly (p < 0.001) from old (44.4) and control calves (45.4). The intensive veterinary care and the different entry ages had no positive effect on performance and carcass quality. The iron supply resulted in increased hemoglobin values and in reddish carcass color in more than 50% of the investigated calves.

  4. Performance Indicators: Theory and Practice. Coombe Lodge Report Volume 20, Number 1.

    ERIC Educational Resources Information Center

    Theodossin, Ernest; Thomson, Craig

    1987-01-01

    Two papers on performance indicators are presented: (1) "Quality Control in Education: The Use of Performance Indicators," by Ernest Theodossin, and (2) "Developing and Using a Performance Indicator Instrument," by Theodossin and Craig Thomson. The first paper looks at the relationship between colleges and the manufacturing…

  5. Statistical process control applied to mechanized peanut sowing as a function of soil texture.

    PubMed

    Zerbato, Cristiano; Furlani, Carlos Eduardo Angeli; Ormond, Antonio Tassio Santana; Gírio, Lucas Augusto da Silva; Carneiro, Franciele Morlin; da Silva, Rouverson Pereira

    2017-01-01

    The successful establishment of agricultural crops depends on sowing quality, machinery performance, soil type and conditions, among other factors. This study evaluates the operational quality of mechanized peanut sowing in three soil types (sand, silt, and clay) with variable moisture contents. The experiment was conducted in three locations in the state of São Paulo, Brazil. The track-sampling scheme was used for 80 sampling locations of each soil type. Descriptive statistics and statistical process control (SPC) were used to evaluate the quality indicators of mechanized peanut sowing. The variables had normal distributions and were stable from the viewpoint of SPC. The best performance for peanut sowing density, normal spacing, and the initial seedling growing stand was found for clayey soil followed by sandy soil and then silty soil. Sandy or clayey soils displayed similar results regarding sowing depth, which was deeper than in the silty soil. Overall, the texture and the moisture of clayey soil provided the best operational performance for mechanized peanut sowing.

  6. Statistical process control applied to mechanized peanut sowing as a function of soil texture

    PubMed Central

    Furlani, Carlos Eduardo Angeli; da Silva, Rouverson Pereira

    2017-01-01

    The successful establishment of agricultural crops depends on sowing quality, machinery performance, soil type and conditions, among other factors. This study evaluates the operational quality of mechanized peanut sowing in three soil types (sand, silt, and clay) with variable moisture contents. The experiment was conducted in three locations in the state of São Paulo, Brazil. The track-sampling scheme was used for 80 sampling locations of each soil type. Descriptive statistics and statistical process control (SPC) were used to evaluate the quality indicators of mechanized peanut sowing. The variables had normal distributions and were stable from the viewpoint of SPC. The best performance for peanut sowing density, normal spacing, and the initial seedling growing stand was found for clayey soil followed by sandy soil and then silty soil. Sandy or clayey soils displayed similar results regarding sowing depth, which was deeper than in the silty soil. Overall, the texture and the moisture of clayey soil provided the best operational performance for mechanized peanut sowing. PMID:28742095

  7. Interaction of feel system and flight control system dynamics on lateral flying qualities

    NASA Technical Reports Server (NTRS)

    Bailey, R. E.; Knotts, L. H.

    1990-01-01

    An experimental investigation of the influence of lateral feel system characteristics on fighter aircraft roll flying qualities was conducted using the variable stability USAF NT-33. Forty-two evaluation flights were flown by three engineering test pilots. The investigation utilized the power approach, visual landing task and up-and-away tasks including formation, gun tracking, and computer-generated compensatory attitude tracking tasks displayed on the Head-Up Display. Experimental variations included the feel system frequency, force-deflection gradient, control system command type (force or position input command), aircraft roll mode time constant, control system prefilter frequency, and control system time delay. The primary data were task performance records and evaluation pilot comments and ratings using the Cooper-Harper scale. The data highlight the unique and powerful effect of the feel system of flying qualities. The data show that the feel system is not 'equivalent' in flying qualities influence to analogous control system elements. A lower limit of allowable feel system frequency appears warranted to ensure good lateral flying qualities. Flying qualities criteria should most properly treat the feel system dynamic influence separately from the control system, since the input and output of this dynamic element is apparent to the pilot and thus, does not produce a 'hidden' effect.

  8. Comparison of in-flight and ground-based simulator derived flying qualities and pilot performance for approach and landing tasks

    NASA Technical Reports Server (NTRS)

    Grantham, William D.; Williams, Robert H.

    1987-01-01

    For the case of an approach-and-landing piloting task emphasizing response to the landing flare, pilot opinion and performance parameters derived from jet transport aircraft six-degree-of-freedom ground-based and in-flight simulators were compared in order to derive data for the flight-controls/flying-qualities engineers. The data thus obtained indicate that ground simulation results tend to be conservative, and that the effect of control sensitivity is more pronounced for ground simulation. The pilot also has a greater tendency to generate pilot-induced oscillation in ground-based simulation than in flight.

  9. Preliminary simulation of an advanced, hingless rotor XV-15 tilt-rotor aircraft

    NASA Technical Reports Server (NTRS)

    Mcveigh, M. A.

    1976-01-01

    The feasibility of the tilt-rotor concept was verified through investigation of the performance, stability and handling qualities of the XV-15 tilt rotor. The rotors were replaced by advanced-technology fiberglass/composite hingless rotors of larger diameter, combined with an advanced integrated fly-by-wire control system. A parametric simulation model of the HRXV-15 was developed, model was used to define acceptable preliminary ranges of primary and secondary control schedules as functions of the flight parameters, to evaluate performance, flying qualities and structural loads, and to have a Boeing-Vertol pilot conduct a simulated flight test evaluation of the aircraft.

  10. Automated batch characterization of inkjet-printed elastomer lenses using a LEGO platform.

    PubMed

    Sung, Yu-Lung; Garan, Jacob; Nguyen, Hoang; Hu, Zhenyu; Shih, Wei-Chuan

    2017-09-10

    Small, self-adhesive, inkjet-printed elastomer lenses have enabled smartphone cameras to image and resolve microscopic objects. However, the performance of different lenses within a batch is affected by hard-to-control environmental variables. We present a cost-effective platform to perform automated batch characterization of 300 lens units simultaneously for quality inspection. The system was designed and configured with LEGO bricks, 3D printed parts, and a digital camera. The scheme presented here may become the basis of a high-throughput, in-line inspection tool for quality control purposes and can also be employed for optimization of the manufacturing process.

  11. Quality specification and status of internal quality control of cardiac biomarkers in China from 2011 to 2016.

    PubMed

    Li, Tingting; Wang, Wei; Zhao, Haijian; He, Falin; Zhong, Kun; Yuan, Shuai; Wang, Zhiguo

    2017-09-07

    This study aimed to investigate the status of internal quality control (IQC) for cardiac biomarkers from 2011 to 2016 so that we can have overall knowledge of the precision level of measurements in China and set appropriate precision specifications. Internal quality control data of cardiac biomarkers, including creatinine kinase MB (CK-MB) (μg/L), CK-MB(U/L), myoglobin (Mb), cardiac troponin I (cTnI), cardiac troponin T (cTnT), and homocysteines (HCY), were collected by a web-based external quality assessment (EQA) system. Percentages of laboratories meeting five precision quality specifications for current coefficient of variations (CVs) were calculated. Then, appropriate precision specifications were chosen for these six analytes. Finally, the CVs and IQC practice were further analyzed with different grouping methods. The current CVs remained nearly constant for 6 years. cTnT had the highest pass rates every year against five specifications, whereas HCY had the lowest pass rates. Overall, most analytes had a satisfactory performance (pass rates >80%), except for HCY, if one-third TEa or the minimum specification were employed. When the optimal specification was applied, the performance of most analytes was frustrating (pass rates < 60%) except for cTnT. The appropriate precision specifications of Mb, cTnI, cTnT and HCY were set as current CVs less than 9.20%, 9.90%, 7.50%, 10.54%, 7.63%, and 6.67%, respectively. The data of IQC practices indicated wide variation and substantial progress. The precision performance of cTnT was already satisfying, while the other five analytes, especially HCY, were still frustrating; thus, ongoing investigation and continuous improvement for IQC are still needed. © 2017 Wiley Periodicals, Inc.

  12. Exercise in Patients on Dialysis: A Multicenter, Randomized Clinical Trial

    PubMed Central

    Manfredini, Fabio; Mallamaci, Francesca; D’Arrigo, Graziella; Baggetta, Rossella; Bolignano, Davide; Torino, Claudia; Lamberti, Nicola; Bertoli, Silvio; Ciurlino, Daniele; Rocca-Rey, Lisa; Barillà, Antonio; Battaglia, Yuri; Rapanà, Renato Mario; Zuccalà, Alessandro; Bonanno, Graziella; Fatuzzo, Pasquale; Rapisarda, Francesco; Rastelli, Stefania; Fabrizi, Fabrizio; Messa, Piergiorgio; De Paola, Luciano; Lombardi, Luigi; Cupisti, Adamasco; Fuiano, Giorgio; Lucisano, Gaetano; Summaria, Chiara; Felisatti, Michele; Pozzato, Enrico; Malagoni, Anna Maria; Castellino, Pietro; Aucella, Filippo; Abd ElHafeez, Samar; Provenzano, Pasquale Fabio; Tripepi, Giovanni; Catizone, Luigi

    2017-01-01

    Previous studies have suggested the benefits of physical exercise for patients on dialysis. We conducted the Exercise Introduction to Enhance Performance in Dialysis trial, a 6-month randomized, multicenter trial to test whether a simple, personalized walking exercise program at home, managed by dialysis staff, improves functional status in adult patients on dialysis. The main study outcomes included change in physical performance at 6 months, assessed by the 6-minute walking test and the five times sit-to-stand test, and in quality of life, assessed by the Kidney Disease Quality of Life Short Form (KDQOL-SF) questionnaire. We randomized 296 patients to normal physical activity (control; n=145) or walking exercise (n=151); 227 patients (exercise n=104; control n=123) repeated the 6-month evaluations. The distance covered during the 6-minute walking test improved in the exercise group (mean distance±SD: baseline, 328±96 m; 6 months, 367±113 m) but not in the control group (baseline, 321±107 m; 6 months, 324±116 m; P<0.001 between groups). Similarly, the five times sit-to-stand test time improved in the exercise group (mean time±SD: baseline, 20.5±6.0 seconds; 6 months, 18.2±5.7 seconds) but not in the control group (baseline, 20.9±5.8 seconds; 6 months, 20.2±6.4 seconds; P=0.001 between groups). The cognitive function score (P=0.04) and quality of social interaction score (P=0.01) in the kidney disease component of the KDQOL-SF improved significantly in the exercise arm compared with the control arm. Hence, a simple, personalized, home-based, low-intensity exercise program managed by dialysis staff may improve physical performance and quality of life in patients on dialysis. PMID:27909047

  13. Quality Control of Laser-Beam-Melted Parts by a Correlation Between Their Mechanical Properties and a Three-Dimensional Surface Analysis

    NASA Astrophysics Data System (ADS)

    Grimm, T.; Wiora, G.; Witt, G.

    2017-03-01

    Good correlations between three-dimensional surface analyses of laser-beam-melted parts of nickel alloy HX and their mechanical properties were found. The surface analyses were performed with a confocal microscope, which offers a more profound surface data basis than a conventional, two-dimensional tactile profilometry. This new approach results in a wide range of three-dimensional surface parameters, which were each evaluated with respect to their feasibility for quality control in additive manufacturing. As a result of an automated surface analysis process by the confocal microscope and an industrial six-axis robot, the results are an innovative approach for quality control in additive manufacturing.

  14. [Recent progress of mitochondrial quality control in ischemic heart disease and its role in cardio-protection of vagal nerve].

    PubMed

    Xue, Run-Qing; Xu, Man; Yu, Xiao-Jiang; Liu, Long-Zhu; Zang, Wei-Jin

    2017-10-25

    Ischemic heart disease (IHD) is the life-threatening cardiovascular disease. Mitochondria have emerged as key participants and regulators of cellular energy demands and signal transduction. Mitochondrial quality is controlled by a number of coordinated mechanisms including mitochondrial fission, fusion and mitophagy, which plays an important role in maintaining healthy mitochondria and cardiac function. Recently, dysfunction of each process in mitochondrial quality control has been observed in the ischemic hearts. This review describes the mechanism of mitochondrial dynamics and mitophagy as well as its performance linked to myocardial ischemia. Moreover, in combination with our study, we will discuss the effect of vagal nerve on mitochondria in cardio-protection.

  15. Empirical evaluation of humpback whale telomere length estimates; quality control and factors causing variability in the singleplex and multiplex qPCR methods.

    PubMed

    Olsen, Morten Tange; Bérubé, Martine; Robbins, Jooke; Palsbøll, Per J

    2012-09-06

    Telomeres, the protective cap of chromosomes, have emerged as powerful markers of biological age and life history in model and non-model species. The qPCR method for telomere length estimation is one of the most common methods for telomere length estimation, but has received recent critique for being too error-prone and yielding unreliable results. This critique coincides with an increasing awareness of the potentials and limitations of the qPCR technique in general and the proposal of a general set of guidelines (MIQE) for standardization of experimental, analytical, and reporting steps of qPCR. In order to evaluate the utility of the qPCR method for telomere length estimation in non-model species, we carried out four different qPCR assays directed at humpback whale telomeres, and subsequently performed a rigorous quality control to evaluate the performance of each assay. Performance differed substantially among assays and only one assay was found useful for telomere length estimation in humpback whales. The most notable factors causing these inter-assay differences were primer design and choice of using singleplex or multiplex assays. Inferred amplification efficiencies differed by up to 40% depending on assay and quantification method, however this variation only affected telomere length estimates in the worst performing assays. Our results suggest that seemingly well performing qPCR assays may contain biases that will only be detected by extensive quality control. Moreover, we show that the qPCR method for telomere length estimation can be highly precise and accurate, and thus suitable for telomere measurement in non-model species, if effort is devoted to optimization at all experimental and analytical steps. We conclude by highlighting a set of quality controls which may serve for further standardization of the qPCR method for telomere length estimation, and discuss some of the factors that may cause variation in qPCR experiments.

  16. Empirical evaluation of humpback whale telomere length estimates; quality control and factors causing variability in the singleplex and multiplex qPCR methods

    PubMed Central

    2012-01-01

    Background Telomeres, the protective cap of chromosomes, have emerged as powerful markers of biological age and life history in model and non-model species. The qPCR method for telomere length estimation is one of the most common methods for telomere length estimation, but has received recent critique for being too error-prone and yielding unreliable results. This critique coincides with an increasing awareness of the potentials and limitations of the qPCR technique in general and the proposal of a general set of guidelines (MIQE) for standardization of experimental, analytical, and reporting steps of qPCR. In order to evaluate the utility of the qPCR method for telomere length estimation in non-model species, we carried out four different qPCR assays directed at humpback whale telomeres, and subsequently performed a rigorous quality control to evaluate the performance of each assay. Results Performance differed substantially among assays and only one assay was found useful for telomere length estimation in humpback whales. The most notable factors causing these inter-assay differences were primer design and choice of using singleplex or multiplex assays. Inferred amplification efficiencies differed by up to 40% depending on assay and quantification method, however this variation only affected telomere length estimates in the worst performing assays. Conclusion Our results suggest that seemingly well performing qPCR assays may contain biases that will only be detected by extensive quality control. Moreover, we show that the qPCR method for telomere length estimation can be highly precise and accurate, and thus suitable for telomere measurement in non-model species, if effort is devoted to optimization at all experimental and analytical steps. We conclude by highlighting a set of quality controls which may serve for further standardization of the qPCR method for telomere length estimation, and discuss some of the factors that may cause variation in qPCR experiments. PMID:22954451

  17. Diagnostic performances of the fluorescent spot test for G6PD deficiency in newborns along the Thailand-Myanmar border: A cohort study.

    PubMed

    Thielemans, Laurence; Gornsawun, Gornpan; Hanboonkunupakarn, Borimas; Paw, Moo Kho; Porn, Pen; Moo, Paw Khu; Van Overmeire, Bart; Proux, Stephane; Nosten, François; McGready, Rose; Carrara, Verena I; Bancone, Germana

    2018-01-01

    Background: Glucose-6-phosphate dehydrogenase (G6PD) deficiency is an inherited enzymatic disorder associated with severe neonatal hyperbilirubinemia and acute haemolysis after exposure to certain drugs or infections. The disorder can be diagnosed phenotypically with a fluorescent spot test (FST), which is a simple test that requires training and basic laboratory equipment. This study aimed to assess the diagnostic performances of the FST used on umbilical cord blood by locally-trained staff and to compare test results of the neonates at birth with the results after one month of age. Methods : We conducted a cohort study on newborns at the Shoklo Malaria Research Unit, along the Thai-Myanmar border between January 2015 and May 2016. The FST was performed at birth on the umbilical cord blood by locally-trained staff and quality controlled by specialised technicians at the central laboratory. The FST was repeated after one month of age. Genotyping for common local G6PD mutations was carried out for all discrepant results. Results: FST was performed on 1521 umbilical cord blood samples. Quality control and genotyping revealed 10 misdiagnoses. After quality control, 10.7% of the males (84/786) and 1.2% of the females (9/735) were phenotypically G6PD deficient at birth. The FST repeated at one month of age or later diagnosed 8 additional G6PD deficient infants who were phenotypically normal at birth. Conclusions : This study shows the short-comings of the G6PD FST in neonatal routine screening and highlights the importance of training and quality control. A more conservative interpretation of the FST in male newborns could increase the diagnostic performances. Quantitative point-of-care tests might show higher sensitivity and specificity for diagnosis of G6PD deficiency on umbilical cord blood and should be investigated.

  18. Diagnostic performances of the fluorescent spot test for G6PD deficiency in newborns along the Thailand-Myanmar border: A cohort study

    PubMed Central

    Thielemans, Laurence; Gornsawun, Gornpan; Hanboonkunupakarn, Borimas; Paw, Moo Kho; Porn, Pen; Moo, Paw Khu; Van Overmeire, Bart; Proux, Stephane; Nosten, François; McGready, Rose; Carrara, Verena I.; Bancone, Germana

    2018-01-01

    Background: Glucose-6-phosphate dehydrogenase (G6PD) deficiency is an inherited enzymatic disorder associated with severe neonatal hyperbilirubinemia and acute haemolysis after exposure to certain drugs or infections. The disorder can be diagnosed phenotypically with a fluorescent spot test (FST), which is a simple test that requires training and basic laboratory equipment. This study aimed to assess the diagnostic performances of the FST used on umbilical cord blood by locally-trained staff and to compare test results of the neonates at birth with the results after one month of age. Methods: We conducted a cohort study on newborns at the Shoklo Malaria Research Unit, along the Thai-Myanmar border between January 2015 and May 2016. The FST was performed at birth on the umbilical cord blood by locally-trained staff and quality controlled by specialised technicians at the central laboratory. The FST was repeated after one month of age. Genotyping for common local G6PD mutations was carried out for all discrepant results. Results: FST was performed on 1521 umbilical cord blood samples. Quality control and genotyping revealed 10 misdiagnoses. After quality control, 10.7% of the males (84/786) and 1.2% of the females (9/735) were phenotypically G6PD deficient at birth. The FST repeated at one month of age or later diagnosed 8 additional G6PD deficient infants who were phenotypically normal at birth. Conclusions: This study shows the short-comings of the G6PD FST in neonatal routine screening and highlights the importance of training and quality control. A more conservative interpretation of the FST in male newborns could increase the diagnostic performances. Quantitative point-of-care tests might show higher sensitivity and specificity for diagnosis of G6PD deficiency on umbilical cord blood and should be investigated. PMID:29552643

  19. Do Health Reforms to Improve Quality Have Long-Term Effects? Results of a Follow-Up on a Randomized Policy Experiment in the Philippines.

    PubMed

    Quimbo, Stella; Wagner, Natascha; Florentino, Jhiedon; Solon, Orville; Peabody, John

    2016-02-01

    We tracked doctors who had previously participated in a randomized policy experiment in the Philippines. The original experiment involved 30 district hospitals divided equally into one control site and two intervention sites that increased insurance payments (full insurance support for children under 5 years old) or made bonus payments to hospital staff. During the 3 years of the intervention, quality-as measured by clinical performance and value vignettes-improved and was sustained in both intervention sites compared with controls. Five years after the interventions were discontinued, we remeasured the quality of care of the doctors. We found that the intervention sites continued to have significantly higher quality compared with the control sites. The previously documented quality improvement in intervention sites appears to be sustained; moreover, it was subject to a very low (less than 1% per year) rate of decay in quality scores. Copyright © 2015 John Wiley & Sons, Ltd.

  20. Benefits of physical exercise training on cognition and quality of life in frail older adults.

    PubMed

    Langlois, Francis; Vu, Thien Tuong Minh; Chassé, Kathleen; Dupuis, Gilles; Kergoat, Marie-Jeanne; Bherer, Louis

    2013-05-01

    Frailty is a state of vulnerability associated with increased risks of fall, hospitalization, cognitive deficits, and psychological distress. Studies with healthy senior suggest that physical exercise can help improve cognition and quality of life. Whether frail older adults can show such benefits remains to be documented. A total of 83 participants aged 61-89 years were assigned to an exercise-training group (3 times a week for 12 weeks) or a control group (waiting list). Frailty was determined by a complete geriatric examination using specific criteria. Pre- and post-test measures assessed physical capacity, cognitive performance, and quality of life. Compared with controls, the intervention group showed significant improvement in physical capacity (functional capacities and physical endurance), cognitive performance (executive functions, processing speed, and working memory), and quality of life (global quality of life, leisure activities, physical capacity, social/family relationships, and physical health). Benefits were overall equivalent between frail and nonfrail participants. Physical exercise training leads to improved cognitive functioning and psychological well-being in frail older adults.

  1. Public Reporting of Primary Care Clinic Quality: Accounting for Sociodemographic Factors in Risk Adjustment and Performance Comparison.

    PubMed

    Wholey, Douglas R; Finch, Michael; Kreiger, Rob; Reeves, David

    2018-01-03

    Performance measurement and public reporting are increasingly being used to compare clinic performance. Intended consequences include quality improvement, value-based payment, and consumer choice. Unintended consequences include reducing access for riskier patients and inappropriately labeling some clinics as poor performers, resulting in tampering with stable care processes. Two analytic steps are used to maximize intended and minimize unintended consequences. First, risk adjustment is used to reduce the impact of factors outside providers' control. Second, performance categorization is used to compare clinic performance using risk-adjusted measures. This paper examines the effects of methodological choices, such as risk adjusting for sociodemographic factors in risk adjustment and accounting for patients clustering by clinics in performance categorization, on clinic performance comparison for diabetes care, vascular care, asthma, and colorectal cancer screening. The population includes all patients with commercial and public insurance served by clinics in Minnesota. Although risk adjusting for sociodemographic factors has a significant effect on quality, it does not explain much of the variation in quality. In contrast, taking into account the nesting of patients within clinics in performance categorization has a substantial effect on performance comparison.

  2. Direct energy balance based active disturbance rejection control for coal-fired power plant.

    PubMed

    Sun, Li; Hua, Qingsong; Li, Donghai; Pan, Lei; Xue, Yali; Lee, Kwang Y

    2017-09-01

    The conventional direct energy balance (DEB) based PI control can fulfill the fundamental tracking requirements of the coal-fired power plant. However, it is challenging to deal with the cases when the coal quality variation is present. To this end, this paper introduces the active disturbance rejection control (ADRC) to the DEB structure, where the coal quality variation is deemed as a kind of unknown disturbance that can be estimated and mitigated promptly. Firstly, the nonlinearity of a recent power plant model is analyzed based on the gap metric, which provides guidance on how to set the pressure set-point in line with the power demand. Secondly, the approximate decoupling effect of the DEB structure is analyzed based on the relative gain analysis in frequency domain. Finally, the synthesis of the DEB based ADRC control system is carried out based on multi-objective optimization. The optimized ADRC results show that the integrated absolute error (IAE) indices of the tracking performances in both loops can be simultaneously improved, in comparison with the DEB based PI control and H ∞ control system. The regulation performance in the presence of the coal quality variation is significantly improved under the ADRC control scheme. Moreover, the robustness of the proposed strategy is shown comparable with the H ∞ control. Copyright © 2017. Published by Elsevier Ltd.

  3. MRIQC: Advancing the automatic prediction of image quality in MRI from unseen sites

    PubMed Central

    2017-01-01

    Quality control of MRI is essential for excluding problematic acquisitions and avoiding bias in subsequent image processing and analysis. Visual inspection is subjective and impractical for large scale datasets. Although automated quality assessments have been demonstrated on single-site datasets, it is unclear that solutions can generalize to unseen data acquired at new sites. Here, we introduce the MRI Quality Control tool (MRIQC), a tool for extracting quality measures and fitting a binary (accept/exclude) classifier. Our tool can be run both locally and as a free online service via the OpenNeuro.org portal. The classifier is trained on a publicly available, multi-site dataset (17 sites, N = 1102). We perform model selection evaluating different normalization and feature exclusion approaches aimed at maximizing across-site generalization and estimate an accuracy of 76%±13% on new sites, using leave-one-site-out cross-validation. We confirm that result on a held-out dataset (2 sites, N = 265) also obtaining a 76% accuracy. Even though the performance of the trained classifier is statistically above chance, we show that it is susceptible to site effects and unable to account for artifacts specific to new sites. MRIQC performs with high accuracy in intra-site prediction, but performance on unseen sites leaves space for improvement which might require more labeled data and new approaches to the between-site variability. Overcoming these limitations is crucial for a more objective quality assessment of neuroimaging data, and to enable the analysis of extremely large and multi-site samples. PMID:28945803

  4. Piloting Vertical Flight Aircraft: A Conference on Flying Qualities and Human Factors

    NASA Technical Reports Server (NTRS)

    Blanken, Christopher L. (Editor); Whalley, Matthew S. (Editor)

    1993-01-01

    This document contains papers from a specialists' meeting entitled 'Piloting Vertical Flight Aircraft: A Conference on Flying Qualities and Human Factors.' Vertical flight aircraft, including helicopters and a variety of Vertical Takeoff and Landing (VTOL) concepts, place unique requirements on human perception, control, and performance for the conduct of their design missions. The intent of this conference was to examine, for these vehicles, advances in: (1) design of flight control systems for ADS-33C standards; (2) assessment of human factors influences of cockpit displays and operational procedures; (3) development of VTOL design and operational criteria; and (4) development of theoretical methods or models for predicting pilot/vehicle performance and mission suitability. A secondary goal of the conference was to provide an initial venue for enhanced interaction between human factors and handling qualities specialists.

  5. Faculty Evaluation: Number One Quality Control in TQM [Total Quality Management].

    ERIC Educational Resources Information Center

    Andrews, Hans A.; And Others

    The current perception of faculty tenure as a guarantee of a job for life can impede the removal of teachers who do not perform up to standards. Such faculty, however, can have an extremely negative effect on overall college quality, and studies have shown that community college faculty do support post-tenure evaluation if it is responsibly…

  6. The role of field auditing in environmental quality assurance management.

    PubMed

    Claycomb, D R

    2000-01-01

    Environmental data quality improvement continues to focus on analytical laboratoryperformance with little, if any, attention given to improving the performance of field consultants responsible for sample collection. Many environmental professionals often assume that the primary opportunity for data error lies within the activities conducted by the laboratory. Experience in the evaluation of environmental data and project-wide quality assurance programs indicates that an often-ignored factor affecting environmental data quality is the manner in which a sample is acquired and handled in the field. If a sample is not properly collected, preserved, stored, and transported in the field, even the best laboratory practices and analytical methods cannot deliver accurate and reliable data (i.e., bad data in equals bad data out). Poor quality environmental data may result in inappropriate decisions regarding site characterization and remedial action. Field auditing is becoming an often-employed technique for examining the performance of the environmental sampling field team and how their performance may affect data quality. The field audits typically focus on: (1) verifying that field consultants adhere to project control documents (e.g., Work Plans and Standard Operating Procedures [SOPs]) during field operations; (2) providing third-party independent assurance that field procedures, quality assurance/ quality control (QA/QC)protocol, and field documentation are sufficient to produce data of satisfactory quality; (3) providing a defense in the event that field procedures are called into question; and (4) identifying ways to reduce sampling costs. Field audits are typically most effective when performed on a surprise basis; that is, the sampling contractor may be aware that a field audit will be conducted during some phase of sampling activities but is not informed of the specific day(s) that the audit will be conducted. The audit also should be conducted early on in the sampling program such that deficiencies noted during the audit can be addressed before the majority of field activities have been completed. A second audit should be performed as a follow-up to confirm that the recommended changes have been implemented. A field auditor is assigned to the project by matching, as closely as possible, the auditor's experience with the type of field activities being conducted. The auditor uses a project-specific field audit checklist developed from key information contained in project control documents. Completion of the extensive audit checklist during the audit focuses the auditor on evaluating each aspect of field activities being performed. Rather than examine field team performance after sampling, a field auditor can do so while the samples are being collected and can apply real-time corrective action as appropriate. As a result of field audits, responsible parties often observe vast improvements in their consultant's field procedures and, consequently, receive more reliable and representative field data at a lower cost. The cost savings and improved data quality that result from properly completed field audits make the field auditing process both cost-effective and functional.

  7. Urbanization, regime type and durability, and environmental degradation in Ghana.

    PubMed

    Adams, Samuel; Adom, Philip Kofi; Klobodu, Edem Kwame Mensah

    2016-12-01

    This study examines the effect of urbanization, income, trade openness, and institutional quality (i.e., regime type and durability) on environmental degradation in Ghana over the period 1965-2011. Using the bounds test approach to cointegration and the Fully Modified Phillip-Hansen (FMPH) technique, the findings show that urbanization, income, trade openness, and institutional quality have long-run cointegration with environmental degradation. Further, the results show that income, trade openness, and institutional quality are negatively associated with environmental degradation. This suggests that income, trade openness, and institutional quality enhance environmental performance. Urbanization, however, is positively related to environmental degradation. Additionally, long-run estimates conditioned on institutional quality reveal that the extent to which trade openness and urbanization enhance environmental performance is largely due to the presence of quality institutions (or democratic institutions). Finally, controlling for structural breaks, we find that trade openness, urbanization, and regime type (i.e., democracy) improve environmental performance significantly after the 1970s except for income.

  8. 48 CFR 246.407 - Nonconforming supplies or services.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... SYSTEM, DEPARTMENT OF DEFENSE CONTRACT MANAGEMENT QUALITY ASSURANCE Government Contract Quality Assurance... the material, or perform the service, at no cost to the Government; and (iii) May accept consideration... design control activity is the approval authority for acceptance of any nonconforming aviation or ship...

  9. TESTING, PERFORMANCE VALIDATION AND QUALITY ASSURANCE/QUALITY CONTROL OF FIELD-PORTABLE INSTRUMENTATION

    EPA Science Inventory

    New technologies for field-portable monitoring instruments often have a long lead time in development and authorization. Some obstacles to the acceptance of these pilot technologies include concern about liabilities, reluctance to take risks on new technologies, and uncertainty a...

  10. Hot mix asphalt voids acceptance review of QC/QA data 2000 through 2010.

    DOT National Transportation Integrated Search

    2011-10-01

    This report analyzes the quality control/quality assurance (QC/QA) data for hot mix asphalt (HMA) using : voids acceptance as the testing criteria awarded in the years 2000 through 2010. Analysis of the overall : performance of the projects is accomp...

  11. Stochastic control approaches for sensor management in search and exploitation

    NASA Astrophysics Data System (ADS)

    Hitchings, Darin Chester

    Recent improvements in the capabilities of autonomous vehicles have motivated their increased use in such applications as defense, homeland security, environmental monitoring, and surveillance. To enhance performance in these applications, new algorithms are required to control teams of robots autonomously and through limited interactions with human operators. In this dissertation we develop new algorithms for control of robots performing information-seeking missions in unknown environments. These missions require robots to control their sensors in order to discover the presence of objects, keep track of the objects, and learn what these objects are, given a fixed sensing budget. Initially, we investigate control of multiple sensors, with a finite set of sensing options and finite-valued measurements, to locate and classify objects given a limited resource budget. The control problem is formulated as a Partially Observed Markov Decision Problem (POMDP), but its exact solution requires excessive computation. Under the assumption that sensor error statistics are independent and time-invariant, we develop a class of algorithms using Lagrangian Relaxation techniques to obtain optimal mixed strategies using performance bounds developed in previous research. We investigate alternative Receding Horizon (RH) controllers to convert the mixed strategies to feasible adaptive-sensing strategies and evaluate the relative performance of these controllers in simulation. The resulting controllers provide superior performance to alternative algorithms proposed in the literature and obtain solutions to large-scale POMDP problems several orders of magnitude faster than optimal Dynamic Programming (DP) approaches with comparable performance quality. We extend our results for finite action, finite measurement sensor control to scenarios with moving objects. We use Hidden Markov Models (HMMs) for the evolution of objects, according to the dynamics of a birth-death process. We develop a new lower bound on the performance of adaptive controllers in these scenarios, develop algorithms for computing solutions to this lower bound, and use these algorithms as part of a RH controller for sensor allocation in the presence of moving objects We also consider an adaptive Search problem where sensing actions are continuous and the underlying measurement space is also continuous. We extend our previous hierarchical decomposition approach based on performance bounds to this problem and develop novel implementations of Stochastic Dynamic Programming (SDP) techniques to solve this problem. Our algorithms are nearly two orders of magnitude faster than previously proposed approaches and yield solutions of comparable quality. For supervisory control, we discuss how human operators can work with and augment robotic teams performing these tasks. Our focus is on how tasks are partitioned among teams of robots and how a human operator can make intelligent decisions for task partitioning. We explore these questions through the design of a game that involves robot automata controlled by our algorithms and a human supervisor that partitions tasks based on different levels of support information. This game can be used with human subject experiments to explore the effect of information on quality of supervisory control.

  12. Improvement of mechanical performance for vibratory microgyroscope based on sense mode closed-loop control

    NASA Astrophysics Data System (ADS)

    Xiao, Dingbang; Su, Jianbin; Chen, Zhihua; Hou, Zhanqiang; Wang, Xinghua; Wu, Xuezhong

    2013-04-01

    In order to improve its structural sensitivity, a vibratory microgyroscope is commonly sealed in high vacuum to increase the drive mode quality factor. The sense mode quality factor of the microgyroscope will also increase simultaneously after vacuum sealing, which will lead to a long decay time of free response and even self-oscillation of the sense mode. As a result, the mechanical performance of the microgyroscope will be seriously degraded. In order to solve this problem, a closed-loop control technique is presented to adjust and optimize the sense mode quality factor. A velocity feedback loop was designed to increase the electric damping of the sense mode vibration. A circuit was fabricated based on this technique, and experimental results indicate that the sense mode quality factor of the microgyroscope was adjusted from 8052 to 428. The decay time of the sense mode free response was shortened from 3 to 0.5 s, and the vibration-rejecting ability of the microgyroscope was improved obviously without sensitivity degradation.

  13. Smart ventilation energy and indoor air quality performance in residential buildings: A review

    DOE PAGES

    Guyot, Gaelle; Sherman, Max H.; Walker, Iain S.

    2017-12-30

    To better address energy and indoor air quality issues, ventilation needs to become smarter. A key smart ventilation concept is to use controls to ventilate more at times it provides either an energy or indoor air quality (IAQ) advantage (or both) and less when it provides a disadvantage. A favorable context exists in many countries to include some of the existing smart ventilation strategies in codes and standards. As a result, demand-controlled ventilation (DCV) systems are widely and easily available on the market, with more than 20 DCV systems approved and available in countries such as Belgium, France and themore » Netherlands. This paper provides a literature review on smart ventilation used in residential buildings, based on energy and indoor air quality performance. This meta-analysis includes 38 studies of various smart ventilation systems with control based on CO 2, humidity, combined CO 2 and total volatile organic compounds (TVOC), occupancy, or outdoor temperature. In conclusion, these studies show that ventilation energy savings up to 60% can be obtained without compromising IAQ, even sometimes improving it. However, the meta-analysis included some less than favorable results, with 26% energy overconsumption in some cases.« less

  14. The European general thoracic surgery database project.

    PubMed

    Falcoz, Pierre Emmanuel; Brunelli, Alessandro

    2014-05-01

    The European Society of Thoracic Surgeons (ESTS) Database is a free registry created by ESTS in 2001. The current online version was launched in 2007. It runs currently on a Dendrite platform with extensive data security and frequent backups. The main features are a specialty-specific, procedure-specific, prospectively maintained, periodically audited and web-based electronic database, designed for quality control and performance monitoring, which allows for the collection of all general thoracic procedures. Data collection is the "backbone" of the ESTS database. It includes many risk factors, processes of care and outcomes, which are specially designed for quality control and performance audit. The user can download and export their own data and use them for internal analyses and quality control audits. The ESTS database represents the gold standard of clinical data collection for European General Thoracic Surgery. Over the past years, the ESTS database has achieved many accomplishments. In particular, the database hit two major milestones: it now includes more than 235 participating centers and 70,000 surgical procedures. The ESTS database is a snapshot of surgical practice that aims at improving patient care. In other words, data capture should become integral to routine patient care, with the final objective of improving quality of care within Europe.

  15. A novel frame-level constant-distortion bit allocation for smooth H.264/AVC video quality

    NASA Astrophysics Data System (ADS)

    Liu, Li; Zhuang, Xinhua

    2009-01-01

    It is known that quality fluctuation has a major negative effect on visual perception. In previous work, we introduced a constant-distortion bit allocation method [1] for H.263+ encoder. However, the method in [1] can not be adapted to the newest H.264/AVC encoder directly as the well-known chicken-egg dilemma resulted from the rate-distortion optimization (RDO) decision process. To solve this problem, we propose a new two stage constant-distortion bit allocation (CDBA) algorithm with enhanced rate control for H.264/AVC encoder. In stage-1, the algorithm performs RD optimization process with a constant quantization QP. Based on prediction residual signals from stage-1 and target distortion for smooth video quality purpose, the frame-level bit target is allocated by using a close-form approximations of ratedistortion relationship similar to [1], and a fast stage-2 encoding process is performed with enhanced basic unit rate control. Experimental results show that, compared with original rate control algorithm provided by H.264/AVC reference software JM12.1, the proposed constant-distortion frame-level bit allocation scheme reduces quality fluctuation and delivers much smoother PSNR on all testing sequences.

  16. Smart ventilation energy and indoor air quality performance in residential buildings: A review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guyot, Gaelle; Sherman, Max H.; Walker, Iain S.

    To better address energy and indoor air quality issues, ventilation needs to become smarter. A key smart ventilation concept is to use controls to ventilate more at times it provides either an energy or indoor air quality (IAQ) advantage (or both) and less when it provides a disadvantage. A favorable context exists in many countries to include some of the existing smart ventilation strategies in codes and standards. As a result, demand-controlled ventilation (DCV) systems are widely and easily available on the market, with more than 20 DCV systems approved and available in countries such as Belgium, France and themore » Netherlands. This paper provides a literature review on smart ventilation used in residential buildings, based on energy and indoor air quality performance. This meta-analysis includes 38 studies of various smart ventilation systems with control based on CO 2, humidity, combined CO 2 and total volatile organic compounds (TVOC), occupancy, or outdoor temperature. In conclusion, these studies show that ventilation energy savings up to 60% can be obtained without compromising IAQ, even sometimes improving it. However, the meta-analysis included some less than favorable results, with 26% energy overconsumption in some cases.« less

  17. [Quality assurance in interventional cardiology].

    PubMed

    Gülker, H

    2009-10-01

    Quality assurance in clinical studies aiming at approval of pharmaceutical products is submitted to strict rules, controls and auditing regulations. Comparative instruments to ensure quality in diagnostic and therapeutic procedures are not available in interventional cardiology, likewise in other fields of cardiovascular medicine. Quality assurance simply consists of "quality registers" with basic data not externally controlled. Based on the experiences of clinical studies and their long history of standardization it is assumed that these data may be severely flawed thus being inappropriate to set standards for diagnostic and therapeutic strategies. The precondition for quality assurance are quality data. In invasive coronary angiography and intervention medical indications, the decision making process interventional versus surgical revascularization, technical performance and after - care are essential aspects affecting quality of diagnostics and therapy. Quality data are externally controlled data. To collect quality data an appropriate infrastructure is a necessary precondition which is not existent. For an appropriate infrastructure investments have to be done both to build up as well as to sustain the necessary preconditions. As long as there are no infrastructure and no investments there will be no "quality data". There exist simply registers of data which are not proved to be a basis for significant assurance and enhancement in quality in interventional coronary cardiology. Georg Thieme Verlag KG Stuttgart, New York.

  18. The Neuropsychological Profile of Comorbid Post-Traumatic Stress Disorder in Adult ADHD.

    PubMed

    Antshel, Kevin M; Biederman, Joseph; Spencer, Thomas J; Faraone, Stephen V

    2016-12-01

    ADHD and post-traumatic stress disorder (PTSD) are often comorbid yet despite the increased comorbidity between the two disorders, to our knowledge, no data have been published regarding the neuropsychological profile of adults with comorbid ADHD and PTSD. Likewise, previous empirical studies of the neuropsychology of PTSD did not control for ADHD status. We sought to fill this gap in the literature and to assess the extent to which neuropsychological test performance predicted psychosocial functioning, and perceived quality of life. Participants were 201 adults with ADHD attending an outpatient mental health clinic between 1998 and 2003 and 123 controls without ADHD. Participants completed a large battery of self-report measures and psychological tests. Diagnoses were made using data obtained from structured psychiatric interviews (i.e., Structured Clinical Interview for DSM-IV, Schedule for Affective Disorders and Schizophrenia for School-Age Children Epidemiologic Version). Differences emerged between control participants and participants with ADHD on multiple neuropsychological tests. Across all tests, control participants outperformed participants with ADHD. Differences between the two ADHD groups emerged on seven psychological subtests including multiple Wechsler Adult Intelligence Scale-Third edition and Rey-Osterrieth Complex Figure Test measures. These test differences did not account for self-reported quality of life differences between groups. The comorbidity with PTSD in adults with ADHD is associated with weaker cognitive performance on several tasks that appear related to spatial/perceptual abilities and fluency. Neuropsychological test performances may share variance with the quality of life variables yet are not mediators of the quality of life ratings. © The Author(s) 2014.

  19. [Video-based self-control in surgical teaching. A new tool in a new concept].

    PubMed

    Dahmen, U; Sänger, C; Wurst, C; Arlt, J; Wei, W; Dondorf, F; Richter, B; Settmacher, U; Dirsch, O

    2013-10-01

    Image and video-based results and process control are essential tools of a new teaching concept for conveying surgical skills. The new teaching concept integrates approved teaching principles and new media. Every performance of exercises is videotaped and the result photographically recorded. The quality of the process and result becomes accessible for an analysis by the teacher and the student/learner. The learner is instructed to perform a criteria-based self-analysis of the video and image material by themselves. The new learning concept has so far been successfully applied in seven rounds within the newly designed modular class "Intensivkurs Chirurgische Techniken" (Intensive training of surgical techniques). Result documentation and analysis via digital picture was completed by almost every student. The quality of the results was high. Interestingly the result quality did not correlate with the time needed for the exercise. The training success had a lasting effect. The new and elaborate concept improves the quality of teaching. In the long run resources for patient care should be saved when training students according to this concept prior to performing tasks in the operating theater. These resources should be allocated for further refining innovative teaching concepts.

  20. Primary care quality: community health center and health maintenance organization.

    PubMed

    Shi, Leiyu; Starfield, Barbara; Xu, Jiahong; Politzer, Robert; Regan, Jerrilyn

    2003-08-01

    This study compares the primary health care quality of community health centers (CHCs) and health maintenance organizations (HMOs) in South Carolina to elucidate the quality of CHC performance relative to mainstream settings such as the HMO. Mail surveys were used to obtain data from 350 randomly selected HMO users. Surveys with follow-up interviews were conducted to obtain data from 540 randomly selected CHC users. A validated adult primary care assessment tool was used in both surveys. Multivariate analyses were performed to assess the association of health care setting (HMO versus CHC) with primary care quality while controlling for sociodemographic and health care characteristics. After controlling for sociodemographic and health care use measures, CHC patients demonstrated higher scores in several primary care domains (ongoing care, coordination of service, comprehensiveness, and community orientation) as well as total primary care performance. Users of CHC are more likely than HMO users to rate their primary health care provider as good, except in the area of ease of first contact. The positive rating of the CHC is particularly impressive after taking into account that many CHC users have characteristics associated with poorer ratings of care.

  1. Development of An Intelligent Flight Propulsion Control System

    NASA Technical Reports Server (NTRS)

    Calise, A. J.; Rysdyk, R. T.; Leonhardt, B. K.

    1999-01-01

    The initial design and demonstration of an Intelligent Flight Propulsion and Control System (IFPCS) is documented. The design is based on the implementation of a nonlinear adaptive flight control architecture. This initial design of the IFPCS enhances flight safety by using propulsion sources to provide redundancy in flight control. The IFPCS enhances the conventional gain scheduled approach in significant ways: (1) The IFPCS provides a back up flight control system that results in consistent responses over a wide range of unanticipated failures. (2) The IFPCS is applicable to a variety of aircraft models without redesign and,(3) significantly reduces the laborious research and design necessary in a gain scheduled approach. The control augmentation is detailed within an approximate Input-Output Linearization setting. The availability of propulsion only provides two control inputs, symmetric and differential thrust. Earlier Propulsion Control Augmentation (PCA) work performed by NASA provided for a trajectory controller with pilot command input of glidepath and heading. This work is aimed at demonstrating the flexibility of the IFPCS in providing consistency in flying qualities under a variety of failure scenarios. This report documents the initial design phase where propulsion only is used. Results confirm that the engine dynamics and associated hard nonlineaaities result in poor handling qualities at best. However, as demonstrated in simulation, the IFPCS is capable of results similar to the gain scheduled designs of the NASA PCA work. The IFPCS design uses crude estimates of aircraft behaviour. The adaptive control architecture demonstrates robust stability and provides robust performance. In this work, robust stability means that all states, errors, and adaptive parameters remain bounded under a wide class of uncertainties and input and output disturbances. Robust performance is measured in the quality of the tracking. The results demonstrate the flexibility of the IFPCS architecture and the ability to provide robust performance under a broad range of uncertainty. Robust stability is proved using Lyapunov like analysis. Future development of the IFPCS will include integration of conventional control surfaces with the use of propulsion augmentation, and utilization of available lift and drag devices, to demonstrate adaptive control capability under a greater variety of failure scenarios. Further work will specifically address the effects of actuator saturation.

  2. Effect of superdosing phytase on productive performance and egg quality in laying hens.

    PubMed

    Kim, Jong Hyuk; Pitargue, Franco Martinez; Jung, Hyunjung; Han, Gi Ppeum; Choi, Hyeon Seok; Kil, Dong Yong

    2017-07-01

    An experiment was conducted to determine the effect of superdosing phytase on productive performance and egg quality in laying hens. A total of 200 42-wk-old Hy-Line Brown laying hens were allotted into 1 of 5 dietary treatments with 5 replicates consisting of 8 hens per replicate. The positive control (PC) and negative control diets (NC) were prepared based on the recommended P levels in layer diets. Supplemental phytase was added to the negative control diet at 10,000 (SD10), 20,000 (SD20), or 30,000 (SD30) fytase units (FTU)/kg. Productive performance was summarized for 6 weeks from 42 weeks to 47 weeks of age. Egg quality was assessed from 4 eggs per replicate randomly collected at the conclusion of the experiment. The SD20 treatment had greater (p<0.05) hen-day egg production than PC, NC, and SD10 treatment groups. There was no difference in hen-day egg production between SD20 and SD30 treatment groups. However, SD30 treatment had greater (p<0.05) hen-day egg production than PC treatment, but showed no difference in hen-day egg production as compared to NC and SD10 treatment groups. However, egg weight, egg mass, feed intake, and feed conversion ratio were not affected by dietary treatments. Egg quality including eggshell strength, eggshell color, egg yolk color, and haugh unit was not influenced by dietary treatments. Superdosing level of 20,000 FTU/kg phytase in diets has a positive effect on egg production rate, but no beneficial effect on egg quality in laying hens.

  3. Analyses and tests of the B-1 aircraft structural mode control system

    NASA Technical Reports Server (NTRS)

    Wykes, J. H.; Byar, T. R.; Macmiller, C. J.; Greek, D. C.

    1980-01-01

    Analyses and flight tests of the B-1 structural mode control system (SMCS) are presented. Improvements in the total dynamic response of a flexible aircraft and the benefits to ride qualities, handling qualities, crew efficiency, and reduced dynamic loads on the primary structures, were investigated. The effectiveness and the performance of the SMCS, which uses small aerodynamic surfaces at the vehicle nose to provide damping to the structural modes, were evaluated.

  4. Complexity and Pilot Workload Metrics for the Evaluation of Adaptive Flight Controls on a Full Scale Piloted Aircraft

    NASA Technical Reports Server (NTRS)

    Hanson, Curt; Schaefer, Jacob; Burken, John J.; Larson, David; Johnson, Marcus

    2014-01-01

    Flight research has shown the effectiveness of adaptive flight controls for improving aircraft safety and performance in the presence of uncertainties. The National Aeronautics and Space Administration's (NASA)'s Integrated Resilient Aircraft Control (IRAC) project designed and conducted a series of flight experiments to study the impact of variations in adaptive controller design complexity on performance and handling qualities. A novel complexity metric was devised to compare the degrees of simplicity achieved in three variations of a model reference adaptive controller (MRAC) for NASA's F-18 (McDonnell Douglas, now The Boeing Company, Chicago, Illinois) Full-Scale Advanced Systems Testbed (Gen-2A) aircraft. The complexity measures of these controllers are also compared to that of an earlier MRAC design for NASA's Intelligent Flight Control System (IFCS) project and flown on a highly modified F-15 aircraft (McDonnell Douglas, now The Boeing Company, Chicago, Illinois). Pilot comments during the IRAC research flights pointed to the importance of workload on handling qualities ratings for failure and damage scenarios. Modifications to existing pilot aggressiveness and duty cycle metrics are presented and applied to the IRAC controllers. Finally, while adaptive controllers may alleviate the effects of failures or damage on an aircraft's handling qualities, they also have the potential to introduce annoying changes to the flight dynamics or to the operation of aircraft systems. A nuisance rating scale is presented for the categorization of nuisance side-effects of adaptive controllers.

  5. From quality markers to data mining and intelligence assessment: A smart quality-evaluation strategy for traditional Chinese medicine based on quality markers.

    PubMed

    Bai, Gang; Zhang, Tiejun; Hou, Yuanyuan; Ding, Guoyu; Jiang, Min; Luo, Guoan

    2018-05-15

    The quality of traditional Chinese medicine (TCM) forms the foundation of its clinical efficacy. The standardization of TCM is the most important task of TCM modernization. In recent years, there has been great progress in the quality control of TCM. However, there are still many issues related to the current quality standards, and it is difficult to objectively evaluate and effectively control the quality of TCM. To face these challenge, we summarized the current quality marker (Q-marker) research based on its characteristics and benefits, and proposed a reasonable and intelligentized quality evaluation strategy for the development and application of Q-markers. Ultra-performance liquid chromatography-quadrupole/time-of-flight with partial least squares-discriminant analysis was suggested to screen the chemical markers from Chinese medicinal materials (CMM), and a bioactive-guided evaluation method was used to select the Q-markers. Near-infrared spectroscopy (NIRS), based on the distinctive wavenumber zones or points from the Q-markers, was developed for its determination. Then, artificial intelligence algorithms were used to clarify the complex relationship between the Q-markers and their integral functions. Internet and mobile communication technology helped us to perform remote analysis and determine the information feedback of test samples. The quality control research, evaluation, standard establishment and quality control of TCM must be based on the systematic analysis of Q-markers to study and describe the material basis of TCM efficacy, define the chemical markers in the plant body, and understand the process of herb drug acquisition, change and transmission laws affecting metabolism and exposure. Based on the advantages of chemometrics, new sensor technologies, including infrared spectroscopy, hyperspectral imaging, chemical imaging, electronic nose and electronic tongue, have become increasingly important in the quality evaluation of CMM. Inspired by the concept of Q-marker, the quantitation can be achieved with the help of artificial intelligence, and these subtle differences can be discovered, allowing the quantitative analysis by NIRS and providing a quick and easy detection method for CMM quality evaluations. The concept of Q-markers focused on unique CMM differences, dynamic changes and their transmission and traceability to establish an overall quality control and traceability system. Based on the basic attributes, an integration model and artificial intelligence research path was proposed, with the hope of providing new ideas and perspectives for the TCM quality management. Copyright © 2018 Elsevier GmbH. All rights reserved.

  6. Research on control strategy based on fuzzy PR for grid-connected inverter

    NASA Astrophysics Data System (ADS)

    Zhang, Qian; Guan, Weiguo; Miao, Wen

    2018-04-01

    In the traditional PI controller, there is static error in tracking ac signals. To solve the problem, the control strategy of a fuzzy PR and the grid voltage feed-forward is proposed. The fuzzy PR controller is to eliminate the static error of the system. It also adjusts parameters of PR controller in real time, which avoids the defect of fixed parameter fixed. The grid voltage feed-forward control can ensure the quality of current and improve the system's anti-interference ability when the grid voltage is distorted. Finally, the simulation results show that the system can output grid current with good quality and also has good dynamic and steady state performance.

  7. Quality of Voluntary Medical Male Circumcision Services during Scale-Up: A Comparative Process Evaluation in Kenya, South Africa, Tanzania and Zimbabwe

    PubMed Central

    Jennings, Larissa; Bertrand, Jane; Rech, Dino; Harvey, Steven A.; Hatzold, Karin; Samkange, Christopher A.; Omondi Aduda, Dickens S.; Fimbo, Bennett; Cherutich, Peter; Perry, Linnea; Castor, Delivette; Njeuhmeli, Emmanuel

    2014-01-01

    Background The rapid expansion of voluntary medical male circumcision (VMMC) has raised concerns whether health systems can deliver and sustain VMMC according to minimum quality criteria. Methods and Findings A comparative process evaluation was used to examine data from SYMMACS, the Systematic Monitoring of the Voluntary Medical Male Circumcision Scale-Up, among health facilities providing VMMC across two years of program scale-up. Site-level assessments examined the availability of guidelines, supplies and equipment, infection control, and continuity of care services. Direct observation of VMMC surgeries were used to assess care quality. Two sample tests of proportions and t-tests were used to examine differences in the percent of facilities meeting requisite preparedness standards and the mean number of directly-observed surgical tasks performed correctly. Results showed that safe, high quality VMMC can be implemented and sustained at-scale, although substantial variability was observed over time. In some settings, facility preparedness and VMMC service quality improved as the number of VMMC facilities increased. Yet, lapses in high performance and expansion of considerably deficient services were also observed. Surgical tasks had the highest quality scores, with lower performance levels in infection control, pre-operative examinations, and post-operative patient monitoring and counseling. The range of scale-up models used across countries additionally underscored the complexity of delivering high quality VMMC. Conclusions Greater efforts are needed to integrate VMMC scale-up and quality improvement processes in sub-Saharan African settings. Monitoring of service quality, not just adverse events reporting, will be essential in realizing the full health impact of VMMC for HIV prevention. PMID:24801073

  8. Verification Testing of Air Pollution Control Technology Quality Management Plan Revision 2.3

    EPA Pesticide Factsheets

    The Air Pollution Control Technology Verification Center was established in 1995 as part of the EPA’s Environmental Technology Verification Program to accelerate the development and commercialization of improved environmental technologies’ performance.

  9. ENVIRONMENTAL TECHNOLOGY VERIFICATION FOR AIR POLLUTION CONTROL TECHNOLOGIES: FINAL REPORT

    EPA Science Inventory

    The technical objective of the Environmental Technology Verification (ETV) Program's Air Pollution Control Technology (APCT) Center is to verify environmental technology performance by obtaining objective quality-assured data, thus providing potential purchasers and permitters wi...

  10. Model of epidemic control based on quarantine and message delivery

    NASA Astrophysics Data System (ADS)

    Wang, Xingyuan; Zhao, Tianfang; Qin, Xiaomeng

    2016-09-01

    The model provides two novel strategies for the preventive control of epidemic diseases. One approach is related to the different isolating rates in latent period and invasion period. Experiments show that the increasing of isolating rates in invasion period, as long as over 0.5, contributes little to the preventing of epidemic; the improvement of isolation rate in latent period is key to control the disease spreading. Another is a specific mechanism of message delivering and forwarding. Information quality and information accumulating process are also considered there. Macroscopically, diseases are easy to control as long as the immune messages reach a certain quality. Individually, the accumulating messages bring people with certain immunity to the disease. Also, the model is performed on the classic complex networks like scale-free network and small-world network, and location-based social networks. Results show that the proposed measures demonstrate superior performance and significantly reduce the negative impact of epidemic disease.

  11. Pay for performance in orthopaedic surgery.

    PubMed

    Pierce, Read G; Bozic, Kevin J; Bradford, David S

    2007-04-01

    In recent decades American medicine has undergone tremendous changes. Numerous reimbursement and systems approaches to controlling medical inflation and improving quality have failed to provide cost-effective, high-quality health care in most circumstances. Public and private payers are currently implementing pay for performance, a new reimbursement method linking physician pay to evidence of adherence to performance measures, to constrain costs, encourage efficiency, and maximize value for health care dollars. High-quality research regarding pay for performance and its impact is scarce, particularly in orthopaedic surgery. Although supporters argue pay for performance will remedy the fragmented, costly delivery of health services in the United States, skeptics raise concerns about disagreement over quality guidelines, financial implications for providers and hospitals, inadequate infrastructure, public reporting, system gaming, and physician support. Our survey of orthopaedic surgeons reveals limited understanding of pay for performance, marked skepticism of nonphysician stakeholders' intentions, and a strong desire for greater clinician involvement in shaping the pay for performance movement. As pay for performance will likely be a long-term change that will have an impact on every orthopaedic surgeon, clinician awareness and participation will be fundamental in creating successful pay for performance programs.

  12. 29 CFR 1910.7 - Definition and requirements for a nationally recognized testing laboratory.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., written testing procedures, and calibration and quality control programs) to perform: (i) Testing and... test standards; or (ii) Experimental testing and examining of equipment and materials for workplace..., labeled, or accepted, the following controls or services: (i) Implements control procedures for...

  13. Quality Control and Nondestructive Evaluation Techniques for Composites. Part 1. Overview of Characterization Techniques for Composite Reliability

    DTIC Science & Technology

    1982-05-01

    MONITORING AND MANAGEMENT , 34 7.0 NONDESTRUCTIVE EVALUATION ( NDE ) 37 8. 0 SURFACE NDE 44 9.0 PERFORMANCE AND PROOF TESTING 46 10.0 SUMMARY AND...Chemical Quality Assurance Testing 2. Processability Testing 3. Cure Monitoring and Management 4. Nondestructive Evaluation ( NDE ) 5. Performance and...the management concept for implementing the specific tests. Chemical analysis, nondestructive evaluation ( NDE ) and environmental fatigue testing of

  14. Quality control in diagnostic immunohistochemistry: integrated on-slide positive controls.

    PubMed

    Bragoni, A; Gambella, A; Pigozzi, S; Grigolini, M; Fiocca, R; Mastracci, L; Grillo, F

    2017-11-01

    Standardization in immunohistochemistry is a priority in modern pathology and requires strict quality control. Cost containment has also become fundamental and auditing of all procedures must take into account both these principles. Positive controls must be routinely performed so that their positivity guarantees the appropriateness of the immunohistochemical procedure. The aim of this study is to develop a low cost (utilizing a punch biopsy-PB-tool) procedure to construct positive controls which can be integrated in the patient's tissue slide. Sixteen frequently used control blocks were selected and multiple cylindrical samples were obtained using a 5-mm diameter punch biopsy tool, separately re-embedding them in single blocks. For each diagnostic immunoreaction requiring a positive control, an integrated PB-control section (cut from the appropriate PB-control block) was added to the top right corner of the diagnostic slide before immunostaining. This integrated control technique permitted a saving of 4.75% in total direct lab costs and proved to be technically feasible and reliable. Our proposal is easy to perform and within the reach of all pathology labs, requires easily available tools, its application costs is less than using external paired controls and ensures that a specific control for each slide is always available.

  15. Optimizing construction quality management of pavements using mechanistic performance analysis.

    DOT National Transportation Integrated Search

    2004-08-01

    This report presents a statistical-based algorithm that was developed to reconcile the results from several pavement performance models used in the state of practice with systematic process control techniques. These algorithms identify project-specif...

  16. Development of quality control and instrumentation performance metrics for diffuse optical spectroscopic imaging instruments in the multi-center clinical environment

    NASA Astrophysics Data System (ADS)

    Keene, Samuel T.; Cerussi, Albert E.; Warren, Robert V.; Hill, Brian; Roblyer, Darren; Leproux, AnaÑ--s.; Durkin, Amanda F.; O'Sullivan, Thomas D.; Haghany, Hosain; Mantulin, William W.; Tromberg, Bruce J.

    2013-03-01

    Instrument equivalence and quality control are critical elements of multi-center clinical trials. We currently have five identical Diffuse Optical Spectroscopic Imaging (DOSI) instruments enrolled in the American College of Radiology Imaging Network (ACRIN, #6691) trial located at five academic clinical research sites in the US. The goal of the study is to predict the response of breast tumors to neoadjuvant chemotherapy in 60 patients. In order to reliably compare DOSI measurements across different instruments, operators and sites, we must be confident that the data quality is comparable. We require objective and reliable methods for identifying, correcting, and rejecting low quality data. To achieve this goal, we developed and tested an automated quality control algorithm that rejects data points below the instrument noise floor, improves tissue optical property recovery, and outputs a detailed data quality report. Using a new protocol for obtaining dark-noise data, we applied the algorithm to ACRIN patient data and successfully improved the quality of recovered physiological data in some cases.

  17. Quality evaluation of Hypericum ascyron extract by two-dimensional high-performance liquid chromatography coupled with the colorimetric 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide method.

    PubMed

    Li, Xiu-Mei; Luo, Xue-Gang; Zhang, Chao-Zheng; Wang, Nan; Zhang, Tong-Cun

    2015-02-01

    In this paper, a heart-cutting two-dimensional high-performance liquid chromatography coupled with the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) method was established for controlling the quality of different batches of Hypericum ascyron extract for the first time. In comparison with the common one-dimensional fingerprint, the second-dimensional fingerprint compiled additional spectral data and was hence more informative. The quality of H. ascyron extract was further evaluated by similarity measures and the same results were achieved, the correlation coefficients of the similarity of ten batches of H. ascyron extract were >0.99. Furthermore, we also evaluated the quality of the ten batches of H. ascyron extract by antibacterial activity. The result demonstrated that the quality of the ten batches of H. ascyron extract was not significantly different by MTT. Finally, we demonstrated that the second-dimensional fingerprint coupled with the MTT method was a more powerful tool to characterize the quality of samples of batch to batch. Therefore the proposed method could be used to comprehensively conduct the quality control of traditional Chinese medicines. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Droplet digital PCR-based EGFR mutation detection with an internal quality control index to determine the quality of DNA.

    PubMed

    Kim, Sung-Su; Choi, Hyun-Jeung; Kim, Jin Ju; Kim, M Sun; Lee, In-Seon; Byun, Bohyun; Jia, Lina; Oh, Myung Ryurl; Moon, Youngho; Park, Sarah; Choi, Joon-Seok; Chae, Seoung Wan; Nam, Byung-Ho; Kim, Jin-Soo; Kim, Jihun; Min, Byung Soh; Lee, Jae Seok; Won, Jae-Kyung; Cho, Soo Youn; Choi, Yoon-La; Shin, Young Kee

    2018-01-11

    In clinical translational research and molecular in vitro diagnostics, a major challenge in the detection of genetic mutations is overcoming artefactual results caused by the low-quality of formalin-fixed paraffin-embedded tissue (FFPET)-derived DNA (FFPET-DNA). Here, we propose the use of an 'internal quality control (iQC) index' as a criterion for judging the minimum quality of DNA for PCR-based analyses. In a pre-clinical study comparing the results from droplet digital PCR-based EGFR mutation test (ddEGFR test) and qPCR-based EGFR mutation test (cobas EGFR test), iQC index ≥ 0.5 (iQC copies ≥ 500, using 3.3 ng of FFPET-DNA [1,000 genome equivalents]) was established, indicating that more than half of the input DNA was amplifiable. Using this criterion, we conducted a retrospective comparative clinical study of the ddEGFR and cobas EGFR tests for the detection of EGFR mutations in non-small cell lung cancer (NSCLC) FFPET-DNA samples. Compared with the cobas EGFR test, the ddEGFR test exhibited superior analytical performance and equivalent or higher clinical performance. Furthermore, iQC index is a reliable indicator of the quality of FFPET-DNA and could be used to prevent incorrect diagnoses arising from low-quality samples.

  19. [Phantom studies of ultrasound equipment for quality improvement in breast diagnosis].

    PubMed

    Madjar, H; Mundinger, A; Lattermann, U; Gufler, H; Prömpeler, H J

    1996-04-01

    According to the German guidelines for quality control of ultrasonic equipment, the following conditions are required for breast ultrasound: A transducer frequency between 5-7.5 MHz and a minimum field of view of 5 cm. Satisfactory images must be obtained in a depth between 0.5 and 4 cm with a wide tolerance of the focal zones. This allows the use of poor quality equipment which does not produce satisfactory image quality and it excludes a number of high frequency and high resolution transducers with a field of view below 5 cm. This study with a test phantom was performed to define image quality objectively. Sixteen ultrasound instruments in different price categories were used to perform standardized examinations on a breast phantom model 550 (ATS Laboratories, Bridgeport, USA). Contrast and spatial resolution in different penetration depths were investigated on cyst phantoms from 1-4 mm diameter and wire targets with defined distances between 0.5-3 mm 4 investigations reported the images. A positive correlation was seen between price category and image quality. This study demonstrates that transducer frequency and image geometry do not allow sufficient quality control. An improvement of ultrasound diagnosis is only possible if equipment guidelines are based on standard examinations with test phantoms.

  20. The effects of clinical pilates exercises on bone mineral density, physical performance and quality of life of women with postmenopausal osteoporosis.

    PubMed

    Angın, Ender; Erden, Zafer; Can, Filiz

    2015-01-01

    The aim of this study was to investigate effects of Clinical Pilates Exercises on bone mineral density (BMD), physical performance and quality of life (QOL) in postmenopausal osteoporosis. Forty-one women were recruited to the study. The subjects were divided into two groups, as the Pilates group and the control group. Subjects were evaluated for BMD at the lumbar region. Physical performance level was measured. Pain intensity level was scored with Visual Analogue Scale. QUALEFFO-41 was used for assessing QOL. BMD values increased in the Pilates group (p < 0.05), while BMD decreased in the control group (p< 0.05). Physical performance test results showed significant increases in the Pilates group (p< 0.05) whereas there was no changes in the control group (p> 0.05). Pain intensity level in the Pilates group was significantly decreased after the exercise (p< 0.05), while it was unchanged in the control group. There were significant increases in all parameters of QOL in the Pilates group. Conversely, some parameters of QOL showed decreases in the control group (p< 0.05). Pilates Exercises is effective to increase BMD; QOL and walking distance and also beneficial to relieve pain. Physiotherapist can use Pilates Exercises for the subjects with osteoporosis in the clinics.

  1. Perception of synthetic speech produced automatically by rule: Intelligibility of eight text-to-speech systems.

    PubMed

    Greene, Beth G; Logan, John S; Pisoni, David B

    1986-03-01

    We present the results of studies designed to measure the segmental intelligibility of eight text-to-speech systems and a natural speech control, using the Modified Rhyme Test (MRT). Results indicated that the voices tested could be grouped into four categories: natural speech, high-quality synthetic speech, moderate-quality synthetic speech, and low-quality synthetic speech. The overall performance of the best synthesis system, DECtalk-Paul, was equivalent to natural speech only in terms of performance on initial consonants. The findings are discussed in terms of recent work investigating the perception of synthetic speech under more severe conditions. Suggestions for future research on improving the quality of synthetic speech are also considered.

  2. Quality assurance and organizational effectiveness in hospitals.

    PubMed Central

    Hetherington, R W

    1982-01-01

    The purpose of this paper is to explore some aspects of a general theoretical model within which research on the organizational impacts of quality assurance programs in hospitals may be examined. Quality assurance is conceptualized as an organizational control mechanism, operating primarily through increased formalization of structures and specification of procedures. Organizational effectiveness is discussed from the perspective of the problem-solving theory of organizations, wherein effective organizations are those which maintain at least average performance in all four system problem areas simultaneously (goal-attainment, integration, adaptation and pattern-maintenance). It is proposed that through the realization of mutual benefits for both professionals and the bureaucracy, quality assurance programs can maximize such effective performance in hospitals. PMID:7096096

  3. Design of optimal buffer layers for CuInGaSe2 thin-film solar cells(Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Lordi, Vincenzo; Varley, Joel B.; He, Xiaoqing; Rockett, Angus A.; Bailey, Jeff; Zapalac, Geordie H.; Mackie, Neil; Poplavskyy, Dmitry; Bayman, Atiye

    2016-09-01

    Optimizing the buffer layer in manufactured thin-film PV is essential to maximize device efficiency. Here, we describe a combined synthesis, characterization, and theory effort to design optimal buffers based on the (Cd,Zn)(O,S) alloy system for CIGS devices. Optimization of buffer composition and absorber/buffer interface properties in light of several competing requirements for maximum device efficiency were performed, along with process variations to control the film and interface quality. The most relevant buffer properties controlling performance include band gap, conduction band offset with absorber, dopability, interface quality, and film crystallinity. Control of an all-PVD deposition process enabled variation of buffer composition, crystallinity, doping, and quality of the absorber/buffer interface. Analytical electron microscopy was used to characterize the film composition and morphology, while hybrid density functional theory was used to predict optimal compositions and growth parameters based on computed material properties. Process variations were developed to produce layers with controlled crystallinity, varying from amorphous to fully epitaxial, depending primarily on oxygen content. Elemental intermixing between buffer and absorber, particularly involving Cd and Cu, also is controlled and significantly affects device performance. Secondary phase formation at the interface is observed for some conditions and may be detrimental depending on the morphology. Theoretical calculations suggest optimal composition ranges for the buffer based on a suite of computed properties and drive process optimizations connected with observed film properties. Prepared by LLNL under Contract DE-AC52-07NA27344.

  4. 76 FR 71568 - Agency Information Collection Activities: Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-18

    ... control number); Title of Information Collection: Nursing Home Quality Improvement Questionnaire; Use: The information obtained via the Nursing Home Quality Improvement Questionnaire will be utilized by CMS staff in... and performance improvement (QAPI) technical assistance (TA) that will be useful to nursing facilities...

  5. Performance-based quality assurance/quality control (QA/QC) acceptance procedures for in-place soil testing phase 3 : [summary].

    DOT National Transportation Integrated Search

    2015-01-01

    Acceptance of earthwork construction by the Florida Department of Transportation (FDOT) : requires in-place testing conducted with a nuclear density gauge (NDG) to determine : dry density, which must obtain a required percent compaction based upon a ...

  6. Impact of flying qualities on mission effectiveness for helicopter air combat

    NASA Technical Reports Server (NTRS)

    Harris, T. M.; Beerman, D. A.; Bivens, C. C.

    1984-01-01

    Battlefield nap-of-the-earth (NOE) helicopter operations are vital for a use of the helicopter in a high-threat environment. As the pilot's workload in this flight regime is very high, the helicopter's handling qualities become an important factor. The present investigation is concerned with overall mission effectiveness, flying qualities, and their interaction with other parameters. A description is presented of a study which generated a significant amount of date relating the importance of flying qualities to the ability to perform several specific mission tasks. It was found that flying qualities do have a major impact on the ability to perform a specific mission. The impact of flying qualities on Scout helicopter mission effectiveness is mainly related to the probability of being detected. The flying qualities effect most critical to the Scout mission was found to be precision of hover control.

  7. Benchmarking and audit of breast units improves quality of care

    PubMed Central

    van Dam, P.A.; Verkinderen, L.; Hauspy, J.; Vermeulen, P.; Dirix, L.; Huizing, M.; Altintas, S.; Papadimitriou, K.; Peeters, M.; Tjalma, W.

    2013-01-01

    Quality Indicators (QIs) are measures of health care quality that make use of readily available hospital inpatient administrative data. Assessment quality of care can be performed on different levels: national, regional, on a hospital basis or on an individual basis. It can be a mandatory or voluntary system. In all cases development of an adequate database for data extraction, and feedback of the findings is of paramount importance. In the present paper we performed a Medline search on “QIs and breast cancer” and “benchmarking and breast cancer care”, and we have added some data from personal experience. The current data clearly show that the use of QIs for breast cancer care, regular internal and external audit of performance of breast units, and benchmarking are effective to improve quality of care. Adherence to guidelines improves markedly (particularly regarding adjuvant treatment) and there are data emerging showing that this results in a better outcome. As quality assurance benefits patients, it will be a challenge for the medical and hospital community to develop affordable quality control systems, which are not leading to excessive workload. PMID:24753926

  8. Quality control for quantitative PCR based on amplification compatibility test.

    PubMed

    Tichopad, Ales; Bar, Tzachi; Pecen, Ladislav; Kitchen, Robert R; Kubista, Mikael; Pfaffl, Michael W

    2010-04-01

    Quantitative qPCR is a routinely used method for the accurate quantification of nucleic acids. Yet it may generate erroneous results if the amplification process is obscured by inhibition or generation of aberrant side-products such as primer dimers. Several methods have been established to control for pre-processing performance that rely on the introduction of a co-amplified reference sequence, however there is currently no method to allow for reliable control of the amplification process without directly modifying the sample mix. Herein we present a statistical approach based on multivariate analysis of the amplification response data generated in real-time. The amplification trajectory in its most resolved and dynamic phase is fitted with a suitable model. Two parameters of this model, related to amplification efficiency, are then used for calculation of the Z-score statistics. Each studied sample is compared to a predefined reference set of reactions, typically calibration reactions. A probabilistic decision for each individual Z-score is then used to identify the majority of inhibited reactions in our experiments. We compare this approach to univariate methods using only the sample specific amplification efficiency as reporter of the compatibility. We demonstrate improved identification performance using the multivariate approach compared to the univariate approach. Finally we stress that the performance of the amplification compatibility test as a quality control procedure depends on the quality of the reference set. Copyright 2010 Elsevier Inc. All rights reserved.

  9. Implementation of statistical process control for proteomic experiments via LC MS/MS.

    PubMed

    Bereman, Michael S; Johnson, Richard; Bollinger, James; Boss, Yuval; Shulman, Nick; MacLean, Brendan; Hoofnagle, Andrew N; MacCoss, Michael J

    2014-04-01

    Statistical process control (SPC) is a robust set of tools that aids in the visualization, detection, and identification of assignable causes of variation in any process that creates products, services, or information. A tool has been developed termed Statistical Process Control in Proteomics (SProCoP) which implements aspects of SPC (e.g., control charts and Pareto analysis) into the Skyline proteomics software. It monitors five quality control metrics in a shotgun or targeted proteomic workflow. None of these metrics require peptide identification. The source code, written in the R statistical language, runs directly from the Skyline interface, which supports the use of raw data files from several of the mass spectrometry vendors. It provides real time evaluation of the chromatographic performance (e.g., retention time reproducibility, peak asymmetry, and resolution), and mass spectrometric performance (targeted peptide ion intensity and mass measurement accuracy for high resolving power instruments) via control charts. Thresholds are experiment- and instrument-specific and are determined empirically from user-defined quality control standards that enable the separation of random noise and systematic error. Finally, Pareto analysis provides a summary of performance metrics and guides the user to metrics with high variance. The utility of these charts to evaluate proteomic experiments is illustrated in two case studies.

  10. Impact of rain gauge quality control and interpolation on streamflow simulation: an application to the Warwick catchment, Australia

    NASA Astrophysics Data System (ADS)

    Liu, Shulun; Li, Yuan; Pauwels, Valentijn R. N.; Walker, Jeffrey P.

    2017-12-01

    Rain gauges are widely used to obtain temporally continuous point rainfall records, which are then interpolated into spatially continuous data to force hydrological models. However, rainfall measurements and interpolation procedure are subject to various uncertainties, which can be reduced by applying quality control and selecting appropriate spatial interpolation approaches. Consequently, the integrated impact of rainfall quality control and interpolation on streamflow simulation has attracted increased attention but not been fully addressed. This study applies a quality control procedure to the hourly rainfall measurements obtained in the Warwick catchment in eastern Australia. The grid-based daily precipitation from the Australian Water Availability Project was used as a reference. The Pearson correlation coefficient between the daily accumulation of gauged rainfall and the reference data was used to eliminate gauges with significant quality issues. The unrealistic outliers were censored based on a comparison between gauged rainfall and the reference. Four interpolation methods, including the inverse distance weighting (IDW), nearest neighbors (NN), linear spline (LN), and ordinary Kriging (OK), were implemented. The four methods were firstly assessed through a cross-validation using the quality-controlled rainfall data. The impacts of the quality control and interpolation on streamflow simulation were then evaluated through a semi-distributed hydrological model. The results showed that the Nash–Sutcliffe model efficiency coefficient (NSE) and Bias of the streamflow simulations were significantly improved after quality control. In the cross-validation, the IDW and OK methods resulted in good interpolation rainfall, while the NN led to the worst result. In term of the impact on hydrological prediction, the IDW led to the most consistent streamflow predictions with the observations, according to the validation at five streamflow-gauged locations. The OK method performed second best according to streamflow predictions at the five gauges in the calibration period (01/01/2007–31/12/2011) and four gauges during the validation period (01/01/2012–30/06/2014). However, NN produced the worst prediction at the outlet of the catchment in the validation period, indicating a low robustness. While the IDW exhibited the best performance in the study catchment in terms of accuracy, robustness and efficiency, more general recommendations on the selection of rainfall interpolation methods need to be further explored.

  11. Impact of rain gauge quality control and interpolation on streamflow simulation: an application to the Warwick catchment, Australia

    NASA Astrophysics Data System (ADS)

    Liu, Shulun; Li, Yuan; Pauwels, Valentijn R. N.; Walker, Jeffrey P.

    2018-01-01

    Rain gauges are widely used to obtain temporally continuous point rainfall records, which are then interpolated into spatially continuous data to force hydrological models. However, rainfall measurements and interpolation procedure are subject to various uncertainties, which can be reduced by applying quality control and selecting appropriate spatial interpolation approaches. Consequently, the integrated impact of rainfall quality control and interpolation on streamflow simulation has attracted increased attention but not been fully addressed. This study applies a quality control procedure to the hourly rainfall measurements obtained in the Warwick catchment in eastern Australia. The grid-based daily precipitation from the Australian Water Availability Project was used as a reference. The Pearson correlation coefficient between the daily accumulation of gauged rainfall and the reference data was used to eliminate gauges with significant quality issues. The unrealistic outliers were censored based on a comparison between gauged rainfall and the reference. Four interpolation methods, including the inverse distance weighting (IDW), nearest neighbors (NN), linear spline (LN), and ordinary Kriging (OK), were implemented. The four methods were firstly assessed through a cross-validation using the quality-controlled rainfall data. The impacts of the quality control and interpolation on streamflow simulation were then evaluated through a semi-distributed hydrological model. The results showed that the Nash–Sutcliffe model efficiency coefficient (NSE) and Bias of the streamflow simulations were significantly improved after quality control. In the cross-validation, the IDW and OK methods resulted in good interpolation rainfall, while the NN led to the worst result. In term of the impact on hydrological prediction, the IDW led to the most consistent streamflow predictions with the observations, according to the validation at five streamflow-gauged locations. The OK method performed second best according to streamflow predictions at the five gauges in the calibration period (01/01/2007–31/12/2011) and four gauges during the validation period (01/01/2012–30/06/2014). However, NN produced the worst prediction at the outlet of the catchment in the validation period, indicating a low robustness. While the IDW exhibited the best performance in the study catchment in terms of accuracy, robustness and efficiency, more general recommendations on the selection of rainfall interpolation methods need to be further explored.

  12. 75 FR 63177 - Availability of FY 09 Grantee Performance Evaluation Reports for the Eight States of EPA Region 4...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-14

    ...-year evaluations of eight state air pollution control programs (Alabama Department of Environmental... Management, FL; Louisville Metro Air Pollution Control District, KY; Forsyth County Environmental Affairs... Regional Air Quality Agency, NC; Chattanooga-Hamilton County Air Pollution Control Bureau, TN; Memphis...

  13. Comparative evaluation of two asthma care quality measures among Medicaid beneficiaries.

    PubMed

    Samnaliev, Mihail; Baxter, Jeffrey D; Clark, Robin E

    2009-05-01

    The relative performance of asthma care quality measures has not been evaluated in Medicaid populations. Using complete claims and pharmaceutical data for 19,076 patients with persistent asthma (based on Health Effectiveness and Data Information Set criteria) in five Medicaid populations, we compared the following two measures of asthma care quality: filling prescriptions for controller asthma medications within 1 year and the ratio of controller medication to the total number of asthma medication prescriptions filled within 1 year. We calculated whether meeting each quality measure was associated with decreased odds of emergency department (ED) treatment episodes. We then compared the odds ratios, receiver operating characteristic (ROC) curves, and deviances between models, using each measure to predict ED utilization in Medicaid populations. Although meeting each measure was associated with lower odds of ED utilization, this decrease was larger if the controller asthma medication measure was met rather than the ratio measure. Additionally, models using the controller medication measure had greater areas under the ROC curve and smaller deviances than models using the ratio measure. Both administrative measures of asthma care quality were associated with lower odds of ED utilization. The controller medication measure of asthma care quality may be better than the ratio measure in relation to emergency asthma care utilization by Medicaid beneficiaries.

  14. Effects of rhythmical and extra-rhythmical qualities of music on heart rate during stationary bike activities.

    PubMed

    DI Cagno, Alessandra; Iuliano, Enzo; Fiorilli, Giovanni; Aquino, Giovanna; Giombini, Arrigo; Menotti, Federica; Tsopani, Despina; Calcagno, Giuseppe

    2016-10-01

    The aim of this study was to evaluate the effects of rhythmical and extra-rhythmical qualities of music on the heart rate (HR) and rates of perceived exertion (RPE), during sub-maximal stationary bike activity. HR of 28 female adult participants was monitored during 3 session of physical activity, performed under 3 different conditions: Hi-BPM (music with 150-170 BPM), RHYTHM (rhythmical qualities only of Hi-BPM condition) and control condition without music (CONTROL). Four parameters were analyzed: the highest HR value (High-HR), High-HR minus starting HR (∆HR), time to reach the 75% of Maximal HR (MHR) (TimeTo75%) and time over 75% MHR (TimeOver75%). HR trend analysis was performed to evaluate differences among the three conditions. OMNI-Cycle Scale was administered to evaluate RPE. MANOVA showed significant differences between the three conditions in TimeTo75%, ∆HR (P<0.01) and TimeOver75% (P<0.05). In RHYTHM and CONTROL conditions after reaching 75% MHR, the HR increase were significantly lower than Hi-BPM (P<0.01). No significant differences were found in OMNI-Cycle Scale scores of Hi-BPM and RHYTHM whereas RPE was significantly higher in CONTROL condition (P<0.05). Hi-BPM and RHYTHM music allowed a faster reaching of the aerobic training zone compared to CONTROL conditions. Nevertheless, after 75% MHR, extra-rhythmical qualities are necessary to maintain or to increase the working HR levels.

  15. Effectiveness of aerobic gymnastic exercise on stress, fatigue, and sleep quality during postpartum: A pilot randomized controlled trial.

    PubMed

    Yang, Chiu-Ling; Chen, Chung-Hey

    2018-01-01

    Gymnastics is a preferable safe exercise for postnatal women performing regularly. The aim of this pilot randomized controlled trial was to determine whether the aerobic gymnastic exercise improves stress, fatigue, sleep quality and depression in postpartum women. Single-blinded, randomized controlled trial held from December 2014 until September 2015. Postnatal clinic of a medical center in southern Taiwan. 140 eligible postnatal women were systematically assigned, with a random start to experimental (n=70) or a control (n=70) group. Engage in aerobic gymnastic exercise at least three times (15min per section) a week for three months using compact disc in the home. Perceived Stress Scale, Postpartum Fatigue Scale, Postpartum Sleep Quality Scale, and Edinburgh Postnatal Depression Scale. In a two-way ANOVA with repeated measures, the aerobic gymnastic exercise group showed significant decrease in fatigue after practicing exercise 4 weeks and the positive effects extended to the 12-week posttests. Paired t-tests revealed that aerobic gymnastic exercise participants had improved significantly in perceived stress and fatigue after 4 weeks gymnastic exercise; these positive effects extended to the 12-week posttests. In addition, the changes in physical symptoms-related sleep inefficiency after 12 weeks gymnastic exercise were significantly decreased in the experimental group compared with the control group. The findings can be used to encourage postnatal women to perform moderate-intensity gymnastic exercise in their daily life to reduce their stress, fatigue and improve sleep quality. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Novel mechatronic solutions incorporating inerters for railway vehicle vertical secondary suspensions

    NASA Astrophysics Data System (ADS)

    Matamoros-Sanchez, Alejandra Z.; Goodall, Roger M.

    2015-02-01

    This paper discusses the effects of inerter-based passive networks in the design of novel mechatronic solutions for improving the vertical performance of a bogied railway vehicle. Combinations of inerter-based structures and active suspensions comprise distinct novel mechatronic solutions for the vertical secondary suspension of the vehicle. The parameters of the active and passive parts of the overall configuration are optimised so that a synergy arises to enhance the vehicle vertical performance and simplify common mechatronic suspension design conflicts. The study is performed by combining inerter-based suspensions with well-established active control (output-based and model-based) strategies for ride quality enhancement. Also, a novel nonlinear control strategy, here called 'Adaptive Stiffness', is incorporated for suspension deflection regulation to complement the well-known local implementation of skyhook damping. This would complete a significant set of control strategies to produce general conclusions. The vehicle performance is assessed through the vertical accelerations of the vehicle body as an initial investigation. Attained results show the potential of the inerter concept for innovating mechatronic technologies to achieve substantial improvements in railway vehicle vertical ride quality with reduced actuator force.

  17. Internal quality control: planning and implementation strategies.

    PubMed

    Westgard, James O

    2003-11-01

    The first essential in setting up internal quality control (IQC) of a test procedure in the clinical laboratory is to select the proper IQC procedure to implement, i.e. choosing the statistical criteria or control rules, and the number of control measurements, according to the quality required for the test and the observed performance of the method. Then the right IQC procedure must be properly implemented. This review focuses on strategies for planning and implementing IQC procedures in order to improve the quality of the IQC. A quantitative planning process is described that can be implemented with graphical tools such as power function or critical-error graphs and charts of operating specifications. Finally, a total QC strategy is formulated to minimize cost and maximize quality. A general strategy for IQC implementation is recommended that employs a three-stage design in which the first stage provides high error detection, the second stage low false rejection and the third stage prescribes the length of the analytical run, making use of an algorithm involving the average of normal patients' data.

  18. An Improved Power Quality BIBRED Converter-Based VSI-Fed BLDC Motor Drive

    NASA Astrophysics Data System (ADS)

    Singh, Bhim; Bist, Vashist

    2014-01-01

    This paper presents an IHQRR (integrated high-quality rectifier regulator) BIBRED (boost integrated buck rectifier energy storage DC-DC) converter-based VSI (voltage source inverter)-fed BLDC (brushless DC) motor drive. The speed control of BLDC motor is achieved by controlling the DC link voltage of the VSI using a single voltage sensor. This allows VSI to operate in fundamental frequency switching mode for electronic commutation of BLDC motor which reduces the switching losses due to high-frequency switching used in conventional approach of PWM (pulse width modulation)-based VSI-fed BLDC motor drive. A BIBRED converter is operated in a dual-DCM (discontinuous conduction mode) thus using a voltage follower approach for PFC (power factor correction) and DC link voltage control. The performance of the proposed drive is evaluated for improved power quality over a wide range of speed control and supply voltage variation for demonstrating the behavior of proposed drive. The power quality indices thus obtained are within the recommended limits by international PQ (power quality) standards such as IEC 61000-3-2.

  19. qcML: An Exchange Format for Quality Control Metrics from Mass Spectrometry Experiments*

    PubMed Central

    Walzer, Mathias; Pernas, Lucia Espona; Nasso, Sara; Bittremieux, Wout; Nahnsen, Sven; Kelchtermans, Pieter; Pichler, Peter; van den Toorn, Henk W. P.; Staes, An; Vandenbussche, Jonathan; Mazanek, Michael; Taus, Thomas; Scheltema, Richard A.; Kelstrup, Christian D.; Gatto, Laurent; van Breukelen, Bas; Aiche, Stephan; Valkenborg, Dirk; Laukens, Kris; Lilley, Kathryn S.; Olsen, Jesper V.; Heck, Albert J. R.; Mechtler, Karl; Aebersold, Ruedi; Gevaert, Kris; Vizcaíno, Juan Antonio; Hermjakob, Henning; Kohlbacher, Oliver; Martens, Lennart

    2014-01-01

    Quality control is increasingly recognized as a crucial aspect of mass spectrometry based proteomics. Several recent papers discuss relevant parameters for quality control and present applications to extract these from the instrumental raw data. What has been missing, however, is a standard data exchange format for reporting these performance metrics. We therefore developed the qcML format, an XML-based standard that follows the design principles of the related mzML, mzIdentML, mzQuantML, and TraML standards from the HUPO-PSI (Proteomics Standards Initiative). In addition to the XML format, we also provide tools for the calculation of a wide range of quality metrics as well as a database format and interconversion tools, so that existing LIMS systems can easily add relational storage of the quality control data to their existing schema. We here describe the qcML specification, along with possible use cases and an illustrative example of the subsequent analysis possibilities. All information about qcML is available at http://code.google.com/p/qcml. PMID:24760958

  20. qcML: an exchange format for quality control metrics from mass spectrometry experiments.

    PubMed

    Walzer, Mathias; Pernas, Lucia Espona; Nasso, Sara; Bittremieux, Wout; Nahnsen, Sven; Kelchtermans, Pieter; Pichler, Peter; van den Toorn, Henk W P; Staes, An; Vandenbussche, Jonathan; Mazanek, Michael; Taus, Thomas; Scheltema, Richard A; Kelstrup, Christian D; Gatto, Laurent; van Breukelen, Bas; Aiche, Stephan; Valkenborg, Dirk; Laukens, Kris; Lilley, Kathryn S; Olsen, Jesper V; Heck, Albert J R; Mechtler, Karl; Aebersold, Ruedi; Gevaert, Kris; Vizcaíno, Juan Antonio; Hermjakob, Henning; Kohlbacher, Oliver; Martens, Lennart

    2014-08-01

    Quality control is increasingly recognized as a crucial aspect of mass spectrometry based proteomics. Several recent papers discuss relevant parameters for quality control and present applications to extract these from the instrumental raw data. What has been missing, however, is a standard data exchange format for reporting these performance metrics. We therefore developed the qcML format, an XML-based standard that follows the design principles of the related mzML, mzIdentML, mzQuantML, and TraML standards from the HUPO-PSI (Proteomics Standards Initiative). In addition to the XML format, we also provide tools for the calculation of a wide range of quality metrics as well as a database format and interconversion tools, so that existing LIMS systems can easily add relational storage of the quality control data to their existing schema. We here describe the qcML specification, along with possible use cases and an illustrative example of the subsequent analysis possibilities. All information about qcML is available at http://code.google.com/p/qcml. © 2014 by The American Society for Biochemistry and Molecular Biology, Inc.

  1. [Quality control at the Istituto di Anatomia e Istologia patologica at the Università di Bologna].

    PubMed

    Alampi, G; Baroni, R; Berti, E; Ceccarelli, C; Dina, R; Eusebi, V; Giangaspero, F; Grigioni, F W; Lecce, S; Losi, L

    1994-04-01

    The growing importance in medical practice of a standardized diagnosis in cyto- and histopathology and the recent recommendations for the adoption of standardized schemes for quality control in anatomic pathology by International Committees stimulated the medical staff of the Institute of Anatomic Pathology of the University of Bologna to adopt a pertinent method. The method used by the Department of Pathology of the Yale University (New Haven, Connecticut, USA) was chosen. A Committee for the quality control was appointed and two kinds of controls were set up: an External Quality Assessment (review of the difficult cases by external experts, slide seminars) and an Internal Quality Assessment performed by the members of the Committee on the diagnostic and laboratory routine of the Institute. Such a survey is periodically monitored during the monthly meetings of the Committee and described in the monthly reports. The present paper illustrates the method adopted and the preliminary results obtained in order to stimulate the discussion of such a critical theme in contemporary Anatomic Pathology at a national level.

  2. National Survey on Internal Quality Control Practice for Lipid Parameters in Laboratories of China from 2014 to 2016.

    PubMed

    Ye, Yuanyuan; Wang, Wei; Zhao, Haijian; He, Falin; Zhong, Kun; Yuan, Shuai; Wang, Zhiguo

    2017-09-01

    To investigate the situation of Internal Quality Control (IQC) practice for total cholesterol, triglycerides, HDL-cholesterol and LDL-cholesterol from 2014 to 2016 in laboratories in China and provide improvement measurements. A web-based External Quality Assessment (EQA) system was used to collect IQC data of lipid parameters in laboratories which continuously participated in the national EQA programs in China from 2014 to 2016. Pass rate of the coefficients of variation (CVs) of two level quality controls in four lipid parameters were calculated according to six quality specifications for precision to evaluate the current status of precision level of the four lipid parameters and their change over time in China. 533, 512, 504, and 466 laboratories continuously reported the data of level one for total cholesterol, triglyceride, HDL-cholesterol and LDL-cholesterol, and 212, 210, 208 and 198 laboratories reported the level two, respectively. The percentage of laboratories meeting the quality specification varied based on different criteria. Non-significant change can be found in the pass rate of CVs over time. The number of laboratories using a closed system increased over time, but still only accounted for a small proportion. There is no significant difference in the pass rate of CVs between closed and open systems. Triglycerides currently have a fairly good performance in China. While the performance of laboratories on total cholesterol, HDL-cholesterol and LDL-cholesterol has yet to be improved.

  3. Lacking control over the trade-off between quality and quantity in visual short-term memory.

    PubMed

    Murray, Alexandra M; Nobre, Anna C; Astle, Duncan E; Stokes, Mark G

    2012-01-01

    Visual short-term memory (VSTM) is limited in the quantity and quality of items that can be retained over time. Importantly, these two mnemonic parameters interact: increasing the number of items in VSTM reduces the quality with which they are represented. Here, we ask whether this trade-off is under top-down control. Specifically, we test whether participants can strategically optimise the trade-off between quality and quantity for VSTM according to task demands. We manipulated strategic trade-off by varying expectations about the number of to-be-remembered items (Experiments 1-2) or the precision required for the memory-based judgement (Experiment 3). In a final experiment, we manipulated both variables in a complementary way to maximise the motivation to strategically control the balance between number and the quality of items encoded into VSTM. In different blocks, performance would benefit most either by encoding a large number of items with low precision or by encoding a small number of items with high precision (Experiment 4). In all experiments, we compared VSTM performance on trials matched for mnemonic demand, but within contexts emphasising the quality or quantity of VSTM representations. Across all four experiments, we found no evidence to suggest that participants use this contextual information to bias the balance between the number and precision of items in VSTM. Rather, our data suggest that the trade-off may be determined primarily by stimulus-driven factors at encoding.

  4. Sci-Fri AM: Quality, Safety, and Professional Issues 01: CPQR Technical Quality Control Suite Development including Quality Control Workload Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Malkoske, Kyle; Nielsen, Michelle; Brown, Erika

    A close partnership between the Canadian Partnership for Quality Radiotherapy (CPQR) and the Canadian Organization of Medical Physicist’s (COMP) Quality Assurance and Radiation Safety Advisory Committee (QARSAC) has resulted in the development of a suite of Technical Quality Control (TQC) Guidelines for radiation treatment equipment, that outline specific performance objectives and criteria that equipment should meet in order to assure an acceptable level of radiation treatment quality. The framework includes consolidation of existing guidelines and/or literature by expert reviewers, structured stages of public review, external field-testing and ratification by COMP. The adopted framework for the development and maintenance of themore » TQCs ensures the guidelines incorporate input from the medical physics community during development, measures the workload required to perform the QC tests outlined in each TQC, and remain relevant (i.e. “living documents”) through subsequent planned reviews and updates. This presentation will show the Multi-Leaf Linear Accelerator document as an example of how feedback and cross-national work to achieve a robust guidance document. During field-testing, each technology was tested at multiple centres in a variety of clinic environments. As part of the defined feedback, workload data was captured. This lead to average time associated with testing as defined in each TQC document. As a result, for a medium-sized centre comprising 6 linear accelerators and a comprehensive brachytherapy program, we evaluate the physics workload to 1.5 full-time equivalent physicist per year to complete all QC tests listed in this suite.« less

  5. Application of microscopy technique and high-performance liquid chromatography for quality assessment of the flower bud of Tussilago farfara L. (Kuandonghua)

    PubMed Central

    Li, Da; Liang, Li; Zhang, Jing; Kang, Tingguo

    2015-01-01

    Background: Quality control is one of the bottleneck problems limiting the application and development of traditional Chinese medicine (TCM). In recent years, microscopy and high-performance liquid chromatography (HPLC) techniques have been frequently applied in the quality control of TCM. However, studies combining conventional microscopy and HPLC techniques for the quality control of the flower bud of Tussilago farfara L. (Kuandonghua) have not been reported. Objective: This study was undertaken to evaluate the quality of the flower bud of T. farfara L. and to establish the relationships between the quantity of pollen grains and four main bioactive constituents: tussilagone, chlorogenic acid, rutin and isoquercitrin. Materials and Methods: In this study, microscopic examination was used to quantify microscopic characteristics of the flower bud of T. farfara L., and the chemical components were determined by HPLC. The data were analyzed by Statistical Package for the Social Sciences statistics software. Results: The results of the analysis showed that tussilagone, chlorogenic acid, rutin and isoquercitrin were significantly correlated with the quantity of pollen grains in the flower bud of T. farfara L. There is a positive correlation between them. From these results, it can be deduced that the flower bud of T. farfara L. with a greater quantity of pollen grains should be of better quality. Conclusion: The study showed that the established method can be helpful for evaluating the quality of the flower bud of T. farfara L. based on microscopic characteristic constants and chemical quantitation. PMID:26246737

  6. Radiation protection program for early detection of breast cancer in a mammography facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mariana, Villagomez Casimiro, E-mail: marjim10-66@ciencias.unam.mx, E-mail: cesar@fisica.unam.mx; Cesar, Ruiz Trejo, E-mail: marjim10-66@ciencias.unam.mx, E-mail: cesar@fisica.unam.mx; Ruby, Espejo Fonseca

    Mammography is the best tool for early detection of Breast Cancer. In this diagnostic radiology modality it is necessary to establish the criteria to ensure the proper use and operation of the equipment used to obtain mammographic images in order to contribute to the safe use of ionizing radiation. The aim of the work was to implement at FUCAM-AC the radiation protection program which must be established for patients and radiation workers according to Mexican standards [1–4]. To achieve this goal, radiation protection and quality control manuals were elaborated [5]. Furthermore, a quality control program (QCP) in the mammography systemsmore » (analog/digital), darkroom included, has been implemented. Daily sensitometry, non-variability of the image quality, visualizing artifacts, revision of the equipment mechanical stability, compression force and analysis of repetition studies are some of the QCP routine tests that must be performed by radiological technicians of this institution as a set of actions to ensure the protection of patients. Image quality and patients dose assessment were performed on 4 analog equipment installed in 2 mobile units. In relation to dose assessment, all equipment passed the acceptance criteria (<3 mGy per projection). The image quality test showed that most images (70%)– presented artifacts. A brief summary of the results of quality control tests applied to the equipment and film processor are presented. To maintain an adequate level of quality and safety at FUCAM-AC is necessary that the proposed radiation protection program in this work is applied.« less

  7. Mindfulness Meditation Improves Mood, Quality of Life, and Attention in Adults with Attention Deficit Hyperactivity Disorder

    PubMed Central

    2015-01-01

    Objective. Adults with attention deficit hyperactivity disorder (ADHD) display affective problems and impaired attention. Mood in ADHD can be improved by mindful awareness practices (MAP), but results are mixed regarding the enhancement of attentional performance. Here we evaluated MAP-induced changes in quality of life (QoL), mood, and attention in adult ADHD patients and controls using more measures of attention than prior studies. Methods. Twenty-one ADHD patients and 8 healthy controls underwent 8 weekly MAP sessions; 22 similar patients and 9 controls did not undergo the intervention. Mood and QoL were assessed using validated questionnaires, and attention was evaluated using the Attentional Network Test (ANT) and the Conners Continuous Performance Test (CPT II), before and after intervention. Results. MAP enhanced sustained attention (ANT) and detectability (CPT II) and improved mood and QoL of patients and controls. Conclusion. MAP is a complementary intervention that improves affect and attention of adults with ADHD and controls. PMID:26137496

  8. Mindfulness Meditation Improves Mood, Quality of Life, and Attention in Adults with Attention Deficit Hyperactivity Disorder.

    PubMed

    Bueno, Viviane Freire; Kozasa, Elisa H; da Silva, Maria Aparecida; Alves, Tânia Maria; Louzã, Mario Rodrigues; Pompéia, Sabine

    2015-01-01

    Adults with attention deficit hyperactivity disorder (ADHD) display affective problems and impaired attention. Mood in ADHD can be improved by mindful awareness practices (MAP), but results are mixed regarding the enhancement of attentional performance. Here we evaluated MAP-induced changes in quality of life (QoL), mood, and attention in adult ADHD patients and controls using more measures of attention than prior studies. Twenty-one ADHD patients and 8 healthy controls underwent 8 weekly MAP sessions; 22 similar patients and 9 controls did not undergo the intervention. Mood and QoL were assessed using validated questionnaires, and attention was evaluated using the Attentional Network Test (ANT) and the Conners Continuous Performance Test (CPT II), before and after intervention. MAP enhanced sustained attention (ANT) and detectability (CPT II) and improved mood and QoL of patients and controls. MAP is a complementary intervention that improves affect and attention of adults with ADHD and controls.

  9. The importance of quality assurance/quality control of diagnostics to increase the confidence in global foot-and-mouth disease control.

    PubMed

    De Clercq, K; Goris, N; Barnett, P V; MacKay, D K

    2008-01-01

    The last decade international trade in animals and animal products was liberated and confidence in this global trade can increase only if appropriate control measures are applied. As foot-and-mouth disease (FMD) diagnostics will play an essential role in this respect, the Food and Agriculture Organization European Commission for the Control of Foot-and-Mouth Disease (EUFMD) co-ordinates, in collaboration with the European Commission, several programmes to increase the quality of FMD diagnostics. A quality assurance (QA) system is deemed essential for laboratories involved in certifying absence of FMDV or antibodies against the virus. Therefore, laboratories are encouraged to validate their diagnostic tests fully and to install a continuous quality control (QC) monitoring system. Knowledge of performance characteristics of diagnostics is essential to interpret results correctly and to calculate sample rates in regional surveillance campaigns. Different aspects of QA/QC of classical and new FMD virological and serological diagnostics are discussed in respect to the EU FMD directive (2003/85/EC). We recommended accepting trade certificates only from laboratories participating in international proficiency testing on a regular basis.

  10. Evaluation of thin-layer chromatography methods for quality control of commercial products containing Aesculus hippocastanum, Turnera diffusa, Matricaria recutita, Passiflora incarnata, and Tilia occidentalis.

    PubMed

    Ramírez-Durón, Rosalba; Ceniceros-Almaguer, Lucía; Salazar-Aranda, Ricardo; Salazar-Cavazos, Ma de la Luz; Waksman de Torres, Noemi

    2007-01-01

    In Mexico, plant-derived products with health claims are sold as herbal dietary supplements, and there are no rules for their legal quality control. Aesculus hippocastanum, Turnera diffusa, Matricaria recutita, Passiflora incarnata, and Tilia occidentalis are some of the major commercial products obtained from plants used in this region. In this paper, we describe the effectiveness of thin-layer chromatography methods to provide for the quality control of several commercial products containing these plants. Standardized extracts were used. Of the 49 commercial products analyzed, only 32.65% matched the chromatographic characteristic of standardized extracts. A significant number of commercial products did not match their label, indicating a problem resulting from the lack of regulation for these products. The proposed methods are simple, sensitive, and specific and can be used for routine quality control of raw herbals and formulations of the tested plants. The results obtained show the need to develop simple and reliable analytical methods that can be performed in any laboratory for the purpose of quality control of dietary supplements or commercial herbal products sold in Mexico.

  11. Content dependent selection of image enhancement parameters for mobile displays

    NASA Astrophysics Data System (ADS)

    Lee, Yoon-Gyoo; Kang, Yoo-Jin; Kim, Han-Eol; Kim, Ka-Hee; Kim, Choon-Woo

    2011-01-01

    Mobile devices such as cellular phones and portable multimedia player with capability of playing terrestrial digital multimedia broadcasting (T-DMB) contents have been introduced into consumer market. In this paper, content dependent image quality enhancement method for sharpness and colorfulness and noise reduction is presented to improve perceived image quality on mobile displays. Human visual experiments are performed to analyze viewers' preference. Relationship between the objective measures and the optimal values of image control parameters are modeled by simple lookup tables based on the results of human visual experiments. Content dependent values of image control parameters are determined based on the calculated measures and predetermined lookup tables. Experimental results indicate that dynamic selection of image control parameters yields better image quality.

  12. Sap flow sensors: construction, quality control and comparison.

    PubMed

    Davis, Tyler W; Kuo, Chen-Min; Liang, Xu; Yu, Pao-Shan

    2012-01-01

    This work provides a design for two types of sensors, based on the thermal dissipation and heat ratio methods of sap flow calculation, for moderate to large scale deployments for the purpose of monitoring tree transpiration. These designs include a procedure for making these sensors, a quality control method for the final products, and a complete list of components with vendors and pricing information. Both sensor designs were field tested alongside a commercial sap flow sensor to assess their performance and show the importance for quality controlling the sensor outputs. Results show that for roughly 2% of the cost of commercial sensors, self-made sap flow sensors can provide acceptable estimates of the sap flow measurements compared to the commercial sensors.

  13. Production of Near-Mirror Surface Quality by Precision Grinding

    NASA Technical Reports Server (NTRS)

    Dimofte, Florin; Krantz, Timothy

    2003-01-01

    Mechanical components such as gears and bearings operate with the working surfaces in intimate contact with a mating part. The performance of such components will be influenced by the quality of the working surface. In general, a smoother surface will perform better than a rougher surface since the lubrication conditions are improved. For example, surfaces with a special near-mirror quality finish of low roughness performed better than ground surfaces when tested using a block-on-ring arrangement. Bearings with near-mirror quality have been tested and analyzed; lower running torques were measured and improved fatigue life was anticipated. Experiments have been done to evaluate the performance of gears with improved, low roughness surface finishing. The measured performance improvements include an increased scuffing (scoring) load capacity by a factor of 1.6, a 30-percent reduction of gear tooth running friction, and longer fatigue lives by a factor of about four. One can also anticipate that near-mirror quality surface finishing could improve the performance of other mechanical components such as mechanical seals and heavily loaded journal bearings. Given these demonstrated benefits, capable and economical methods for the production of mechanical components with near-mirror quality surfaces are desired. One could propose the production of near-mirror quality surfaces by several methods such as abrasive polishing, chemical assisted polishing, or grinding. Production of the surfaces by grinding offers the possibility to control the macro-geometry (form), waviness, and surface texture with one process. The present study was carried out to investigate the possibility of producing near-mirror quality surfaces by grinding. The present study makes use of a specially designed grinding machine spindle to improve the surface quality relative to the quality produced when using a spindle of conventional design.

  14. Implementation research to improve quality of maternal and newborn health care, Malawi

    PubMed Central

    Wilhelm, Danielle; Lohmann, Julia; Kambala, Christabel; Chinkhumba, Jobiba; Muula, Adamson S; De Allegri, Manuela

    2017-01-01

    Abstract Objective To evaluate the impact of a performance-based financing scheme on maternal and neonatal health service quality in Malawi. Methods We conducted a non-randomized controlled before and after study to evaluate the effects of district- and facility-level performance incentives for health workers and management teams. We assessed changes in the facilities’ essential drug stocks, equipment maintenance and clinical obstetric care processes. Difference-in-difference regression models were used to analyse effects of the scheme on adherence to obstetric care treatment protocols and provision of essential drugs, supplies and equipment. Findings We observed 33 health facilities, 23 intervention facilities and 10 control facilities and 401 pregnant women across four districts. The scheme improved the availability of both functional equipment and essential drug stocks in the intervention facilities. We observed positive effects in respect to drug procurement and clinical care activities at non-intervention facilities, likely in response to improved district management performance. Birth assistants’ adherence to clinical protocols improved across all studied facilities as district health managers supervised and coached clinical staff more actively. Conclusion Despite nation-wide stock-outs and extreme health worker shortages, facilities in the study districts managed to improve maternal and neonatal health service quality by overcoming bottlenecks related to supply procurement, equipment maintenance and clinical performance. To strengthen and reform health management structures, performance-based financing may be a promising approach to sustainable improvements in quality of health care. PMID:28670014

  15. USAF Test Pilot School. Flying Qualities Textbook, Volume 2, Part 1

    DTIC Science & Technology

    1986-04-01

    Qualities Flight Testing, Performance and Flying Qaulities Branch, Flight Test Engneerd ision, 6510th Test Wing, Air Force Flight Mayst Ce1ter, Edwards...For these aircraft, the program manager may re*uire a mil spec written specifically for the aircraft and control system involwd. 5.20.2 _EL k,Tt...OR MANAGED IN CONTEXT OF MISSION, WITH AVAILABLE PILOT ATTENTION. S UNCONTROLLABLE CONTROL WILL BE LOST DURING SOME PORTION OF MISSION. ACCEPTABLE

  16. Improving labeling efficiency in automatic quality control of MRSI data.

    PubMed

    Pedrosa de Barros, Nuno; McKinley, Richard; Wiest, Roland; Slotboom, Johannes

    2017-12-01

    To improve the efficiency of the labeling task in automatic quality control of MR spectroscopy imaging data. 28'432 short and long echo time (TE) spectra (1.5 tesla; point resolved spectroscopy (PRESS); repetition time (TR)= 1,500 ms) from 18 different brain tumor patients were labeled by two experts as either accept or reject, depending on their quality. For each spectrum, 47 signal features were extracted. The data was then used to run several simulations and test an active learning approach using uncertainty sampling. The performance of the classifiers was evaluated as a function of the number of patients in the training set, number of spectra in the training set, and a parameter α used to control the level of classification uncertainty required for a new spectrum to be selected for labeling. The results showed that the proposed strategy allows reductions of up to 72.97% for short TE and 62.09% for long TE in the amount of data that needs to be labeled, without significant impact in classification accuracy. Further reductions are possible with significant but minimal impact in performance. Active learning using uncertainty sampling is an effective way to increase the labeling efficiency for training automatic quality control classifiers. Magn Reson Med 78:2399-2405, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jassal, K; Sarkar, B; Mohanti, B

    Objective: The study presents the application of a simple concept of statistical process control (SPC) for pre-treatment quality assurance procedure analysis for planar dose measurements performed using 2D-array and a-Si electronic portal imaging device (a-Si EPID). Method: A total of 195 patients of four different anatomical sites: brain (n1=45), head & neck (n2=45), thorax (n3=50) and pelvis (n4=55) were selected for the study. Pre-treatment quality assurance for the clinically acceptable IMRT/VMAT plans was measured with 2D array and a-Si EPID of the accelerator. After the γ-analysis, control charts and the quality index Cpm was evaluated for each cohort. Results: Meanmore » and σ of γ ( 3%/3 mm) were EPID γ %≤1= 99.9% ± 1.15% and array γ %<1 = 99.6% ± 1.06%. Among all plans γ max was consistently lower than for 2D array as compared to a-Si EPID. Fig.1 presents the X-bar control charts for every cohort. Cpm values for a-Si EPID were found to be higher than array, detailed results are presented in table 1. Conclusion: Present study demonstrates the significance of control charts used for quality management purposes in newer radiotherapy clinics. Also, provides a pictorial overview of the clinic performance for the advanced radiotherapy techniques.Higher Cpm values for EPID indicate its higher efficiency than array based measurements.« less

  18. Shaping Performance: Do International Accreditations and Quality Management Really Help?

    ERIC Educational Resources Information Center

    Nigsch, Stefano; Schenker-Wicki, Andrea

    2013-01-01

    In recent years, international accreditations have become an important form of quality management for business schools all over the world. However, given their high costs and the risk of increasing bureaucratisation and control, accreditations remain highly disputed in academia. This paper uses quantitative data to assess whether accreditations…

  19. Performance-based quality assurance/quality control (QA/QC) acceptance procedures for in-place soil testing phase 3.

    DOT National Transportation Integrated Search

    2015-01-01

    One of the objectives of this study was to evaluate soil testing equipment based on its capability of measuring in-place stiffness or modulus values. : As design criteria transition from empirical to mechanistic-empirical, soil test methods and equip...

  20. 75 FR 59973 - Approval and Promulgation of Air Quality Implementation Plans; Maryland; Control of Volatile...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-29

    ...; Cleaning of high precision optics; Stripping; Janitorial cleaning; cleaning of resin, coating, ink, and... laboratories; Cleaning operations in medical device or pharmaceutical manufacturing; and Cleaning operations related to performance or quality assurance testing of coatings, inks, or adhesives. COMAR 26.11.19.09-1...

  1. Development of Process Analytical Technology (PAT) methods for controlled release pellet coating.

    PubMed

    Avalle, P; Pollitt, M J; Bradley, K; Cooper, B; Pearce, G; Djemai, A; Fitzpatrick, S

    2014-07-01

    This work focused on the control of the manufacturing process for a controlled release (CR) pellet product, within a Quality by Design (QbD) framework. The manufacturing process was Wurster coating: firstly layering active pharmaceutical ingredient (API) onto sugar pellet cores and secondly a controlled release (CR) coating. For each of these two steps, development of a Process Analytical Technology (PAT) method is discussed and also a novel application of automated microscopy as the reference method. Ultimately, PAT methods should link to product performance and the two key Critical Quality Attributes (CQAs) for this CR product are assay and release rate, linked to the API and CR coating steps respectively. In this work, the link between near infra-red (NIR) spectra and those attributes was explored by chemometrics over the course of the coating process in a pilot scale industrial environment. Correlations were built between the NIR spectra and coating weight (for API amount), CR coating thickness and dissolution performance. These correlations allow the coating process to be monitored at-line and so better control of the product performance in line with QbD requirements. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Development of a standardized control module for dc-to-dc converters

    NASA Technical Reports Server (NTRS)

    Yu, Y.; Iwens, R. I.; Lee, F. C.; Inouye, L. Y.

    1977-01-01

    The electrical performance of a power processor depends on the quality of its control system. Most of the existing control circuits suffer one or more of the following imperfections that tend to restrict their respective utility: (1) inability to perform different modes of duty cycle control; (2) lack of immunity to output filter parameter changes, and (3) lack of capability to provide power component stress limiting on an instantaneous basis. The three lagging aspects of existing control circuits have been used to define the major objectives of the current Standardized Control Module (SCM) Program. Detailed information on the SCM functional block diagram, its universality, and performance features, circuit description, test results, and modeling and analysis efforts are presented.

  3. How to Sustain Change and Support Continuous Quality Improvement

    PubMed Central

    McQuillan, Rory; Harel, Ziv; Weizman, Adam V.; Thomas, Alison; Nesrallah, Gihad; Bell, Chaim M.; Chan, Christopher T.; Chertow, Glenn M.

    2016-01-01

    To achieve sustainable change, quality improvement initiatives must become the new way of working rather than something added on to routine clinical care. However, most organizational change is not maintained. In this next article in this Moving Points in Nephrology feature on quality improvement, we provide health care professionals with strategies to sustain and support quality improvement. Threats to sustainability may be identified both at the beginning of a project and when it is ready for implementation. The National Health Service Sustainability Model is reviewed as one example to help identify issues that affect long-term success of quality improvement projects. Tools to help sustain improvement include process control boards, performance boards, standard work, and improvement huddles. Process control and performance boards are methods to communicate improvement results to staff and leadership. Standard work is a written or visual outline of current best practices for a task and provides a framework to ensure that changes that have improved patient care are consistently and reliably applied to every patient encounter. Improvement huddles are short, regular meetings among staff to anticipate problems, review performance, and support a culture of improvement. Many of these tools rely on principles of visual management, which are systems transparent and simple so that every staff member can rapidly distinguish normal from abnormal working conditions. Even when quality improvement methods are properly applied, the success of a project still depends on contextual factors. Context refers to aspects of the local setting in which the project operates. Context affects resources, leadership support, data infrastructure, team motivation, and team performance. For these reasons, the same project may thrive in a supportive context and fail in a different context. To demonstrate the practical applications of these quality improvement principles, these principles are applied to a hypothetical quality improvement initiative that aims to promote home dialysis (home hemodialysis and peritoneal dialysis). PMID:27016498

  4. The Effect of the MassHealth Hospital Pay-for-Performance Program on Quality

    PubMed Central

    Ryan, Andrew M; Blustein, Jan

    2011-01-01

    Objective To test the effect of Massachusetts Medicaid's (MassHealth) hospital-based pay-for-performance (P4P) program, implemented in 2008, on quality of care for pneumonia and surgical infection prevention (SIP). Data Hospital Compare process of care quality data from 2004 to 2009 for acute care hospitals in Massachusetts (N = 62) and other states (N = 3,676) and American Hospital Association data on hospital characteristics from 2005. Study Design Panel data models with hospital fixed effects and hospital-specific trends are estimated to test the effect of P4P on composite quality for pneumonia and SIP. This base model is extended to control for the completeness of measure reporting. Further sensitivity checks include estimation with propensity-score matched control hospitals, excluding hospitals in other P4P programs, varying the time period during which the program was assumed to have an effect, and testing the program effect across hospital characteristics. Principal Findings Estimates from our preferred specification, including hospital fixed effects, trends, and the control for measure completeness, indicate small and nonsignificant program effects for pneumonia (−0.67 percentage points, p>.10) and SIP (−0.12 percentage points, p>.10). Sensitivity checks indicate a similar pattern of findings across specifications. Conclusions Despite offering substantial financial incentives, the MassHealth P4P program did not improve quality in the first years of implementation. PMID:21210796

  5. The effects of emotional intelligence training on the job performance of Australian aged care workers.

    PubMed

    Karimi, Leila; Leggat, Sandra G; Bartram, Timothy; Rada, Jiri

    2018-05-09

    Emotional intelligence (EI) training is popular among human resource practitioners, but there is limited evidence of the impact of such training on health care workers. In the current article, we examine the effects of EI training on quality of resident care and worker well-being and psychological empowerment in an Australian aged care facility. We use Bar-On's (1997) conceptualization of EI. We used a quasiexperimental design in 2014-2015 with experimental (training) and control (nontraining) groups of 60 participants in each group in two geographically separate facilities. Our final poststudy sample size was 27 participants for the training group and 17 participants for the control group. Over a 6-month period, we examined whether staff improved their well-being, psychological empowerment, and job performance measured as enhanced quality of care (self-rated and client-rated) by applying skills in EI. The results showed significant improvement among workers in the training group for EI scores, quality of care, general well-being, and psychological empowerment. There were no significant differences for the control group. Through examining the impact of EI training on staff and residents of an aged care facility, we demonstrate the benefits of EI training for higher quality of care delivery. This study demonstrates the practical process through which EI training can improve the work experiences of aged care workers, as well as the quality of care for residents.

  6. Contact Analog/Compressed Symbology Heading Tape Assessment

    NASA Technical Reports Server (NTRS)

    Shively, R. Jay; Atencio, Adolph; Turpin, Terry; Dowell, Susan

    2002-01-01

    A simulation assessed the performance, handling qualities and workload associated with a contact-analog, world-referenced heading tape as implemented on the Comanche Helmet Integrated Display Sight System (HIDSS) when compared with a screen-fixed, compressed heading tape. Six pilots, four active duty Army Aviators and two civilians flew three ADS-33 maneuvers and a traffic pattern in the Ames Vertical Motion Simulation facility. Small, but statistically significant advantages were found for the compressed symbology for handling qualities, workload, and some of the performance measures. It should be noted however that the level of performance and handling qualities for both symbology sets fell within the acceptable tolerance levels. Both symbology sets yield satisfactory handling qualities and performance in velocity stabilization mode and adequate handling qualities in the automatic flight control mode. Pilot comments about the contact analog symbology highlighted the lack of useful rate of change information in the heading tape and "blurring" due to the rapid movement of the heading tape. These issues warrant further study. Care must be taken in interpreting the operational significance of these results. The symbology sets yielded categorically similar data, i.e., acceptable handling qualities and adequate performance, so while the results point to the need for further study, their operational significance has yet to be determined.

  7. Random Forest Application for NEXRAD Radar Data Quality Control

    NASA Astrophysics Data System (ADS)

    Keem, M.; Seo, B. C.; Krajewski, W. F.

    2017-12-01

    Identification and elimination of non-meteorological radar echoes (e.g., returns from ground, wind turbines, and biological targets) are the basic data quality control steps before radar data use in quantitative applications (e.g., precipitation estimation). Although WSR-88Ds' recent upgrade to dual-polarization has enhanced this quality control and echo classification, there are still challenges to detect some non-meteorological echoes that show precipitation-like characteristics (e.g., wind turbine or anomalous propagation clutter embedded in rain). With this in mind, a new quality control method using Random Forest is proposed in this study. This classification algorithm is known to produce reliable results with less uncertainty. The method introduces randomness into sampling and feature selections and integrates consequent multiple decision trees. The multidimensional structure of the trees can characterize the statistical interactions of involved multiple features in complex situations. The authors explore the performance of Random Forest method for NEXRAD radar data quality control. Training datasets are selected using several clear cases of precipitation and non-precipitation (but with some non-meteorological echoes). The model is structured using available candidate features (from the NEXRAD data) such as horizontal reflectivity, differential reflectivity, differential phase shift, copolar correlation coefficient, and their horizontal textures (e.g., local standard deviation). The influence of each feature on classification results are quantified by variable importance measures that are automatically estimated by the Random Forest algorithm. Therefore, the number and types of features in the final forest can be examined based on the classification accuracy. The authors demonstrate the capability of the proposed approach using several cases ranging from distinct to complex rain/no-rain events and compare the performance with the existing algorithms (e.g., MRMS). They also discuss operational feasibility based on the observed strength and weakness of the method.

  8. Comparison of flying qualities derived from in-flight and ground-based simulators for a jet-transport airplane for the approach and landing pilot tasks

    NASA Technical Reports Server (NTRS)

    Grantham, William D.

    1989-01-01

    The primary objective was to provide information to the flight controls/flying qualities engineer that will assist him in determining the incremental flying qualities and/or pilot-performance differences that may be expected between results obtained via ground-based simulation (and, in particular, the six-degree-of-freedom Langley Visual/Motion Simulator (VMS)) and flight tests. Pilot opinion and performance parameters derived from a ground-based simulator and an in-flight simulator are compared for a jet-transport airplane having 32 different longitudinal dynamic response characteristics. The primary pilot tasks were the approach and landing tasks with emphasis on the landing-flare task. The results indicate that, in general, flying qualities results obtained from the ground-based simulator may be considered conservative-especially when the pilot task requires tight pilot control as during the landing flare. The one exception to this, according to the present study, was that the pilots were more tolerant of large time delays in the airplane response on the ground-based simulator. The results also indicated that the ground-based simulator (particularly the Langley VMS) is not adequate for assessing pilot/vehicle performance capabilities (i.e., the sink rate performance for the landing-flare task when the pilot has little depth/height perception from the outside scene presentation).

  9. Vista/F-16 Multi-Axis Thrust Vectoring (MATV) control law design and evaluation

    NASA Technical Reports Server (NTRS)

    Zwerneman, W. D.; Eller, B. G.

    1994-01-01

    For the Multi-Axis Thrust Vectoring (MATV) program, a new control law was developed using multi-axis thrust vectoring to augment the aircraft's aerodynamic control power to provide maneuverability above the normal F-16 angle of attack limit. The control law architecture was developed using Lockheed Fort Worth's offline and piloted simulation capabilities. The final flight control laws were used in flight test to demonstrate tactical benefits gained by using thrust vectoring in air-to-air combat. Differences between the simulator aerodynamics data base and the actual aircraft aerodynamics led to significantly different lateral-directional flying qualities during the flight test program than those identified during piloted simulation. A 'dial-a-gain' flight test control law update was performed in the middle of the flight test program. This approach allowed for inflight optimization of the aircraft's flying qualities. While this approach is not preferred over updating the simulator aerodynamic data base and then updating the control laws, the final selected gain set did provide adequate lateral-directional flying qualities over the MATV flight envelope. The resulting handling qualities and the departure resistance of the aircraft allowed the 422nd_squadron pilots to focus entirely on evaluating the aircraft's tactical utility.

  10. [Methodology for the comprehensive evaluation of the quality of performance of activities of medical and social experts].

    PubMed

    Moskalenko, V F; Gorban', Ie M; Marunich, V V; Ipatov, A V; Sergiieni, O V

    2001-01-01

    The paper scientifically substantiates methodology, approaches, criteria, and control indices for assessment of activities of establishments of medical-and-social performance. Most indices for efficiency and certain indices for week points in the work of establishments of the service depend on interaction thereof with curative- and prophylactic institutions; the best results with the problem of prevention of disability and rehabilitation of invalids are supposed to be achieved through collaborative efforts. Other criteria and intermediate indices having an effect on the quality of activities reflect the resource- and trained personnel supplies of establishments of the service, amount of work, organizational measures designed to raise the quality of medical-and-social expert performance.

  11. Recommendations of the DNA Commission of the International Society for Forensic Genetics (ISFG) on quality control of autosomal Short Tandem Repeat allele frequency databasing (STRidER).

    PubMed

    Bodner, Martin; Bastisch, Ingo; Butler, John M; Fimmers, Rolf; Gill, Peter; Gusmão, Leonor; Morling, Niels; Phillips, Christopher; Prinz, Mechthild; Schneider, Peter M; Parson, Walther

    2016-09-01

    The statistical evaluation of autosomal Short Tandem Repeat (STR) genotypes is based on allele frequencies. These are empirically determined from sets of randomly selected human samples, compiled into STR databases that have been established in the course of population genetic studies. There is currently no agreed procedure of performing quality control of STR allele frequency databases, and the reliability and accuracy of the data are largely based on the responsibility of the individual contributing research groups. It has been demonstrated with databases of haploid markers (EMPOP for mitochondrial mtDNA, and YHRD for Y-chromosomal loci) that centralized quality control and data curation is essential to minimize error. The concepts employed for quality control involve software-aided likelihood-of-genotype, phylogenetic, and population genetic checks that allow the researchers to compare novel data to established datasets and, thus, maintain the high quality required in forensic genetics. Here, we present STRidER (http://strider.online), a publicly available, centrally curated online allele frequency database and quality control platform for autosomal STRs. STRidER expands on the previously established ENFSI DNA WG STRbASE and applies standard concepts established for haploid and autosomal markers as well as novel tools to reduce error and increase the quality of autosomal STR data. The platform constitutes a significant improvement and innovation for the scientific community, offering autosomal STR data quality control and reliable STR genotype estimates. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. SIMPATIQCO: a server-based software suite which facilitates monitoring the time course of LC-MS performance metrics on Orbitrap instruments.

    PubMed

    Pichler, Peter; Mazanek, Michael; Dusberger, Frederico; Weilnböck, Lisa; Huber, Christian G; Stingl, Christoph; Luider, Theo M; Straube, Werner L; Köcher, Thomas; Mechtler, Karl

    2012-11-02

    While the performance of liquid chromatography (LC) and mass spectrometry (MS) instrumentation continues to increase, applications such as analyses of complete or near-complete proteomes and quantitative studies require constant and optimal system performance. For this reason, research laboratories and core facilities alike are recommended to implement quality control (QC) measures as part of their routine workflows. Many laboratories perform sporadic quality control checks. However, successive and systematic longitudinal monitoring of system performance would be facilitated by dedicated automatic or semiautomatic software solutions that aid an effortless analysis and display of QC metrics over time. We present the software package SIMPATIQCO (SIMPle AuTomatIc Quality COntrol) designed for evaluation of data from LTQ Orbitrap, Q-Exactive, LTQ FT, and LTQ instruments. A centralized SIMPATIQCO server can process QC data from multiple instruments. The software calculates QC metrics supervising every step of data acquisition from LC and electrospray to MS. For each QC metric the software learns the range indicating adequate system performance from the uploaded data using robust statistics. Results are stored in a database and can be displayed in a comfortable manner from any computer in the laboratory via a web browser. QC data can be monitored for individual LC runs as well as plotted over time. SIMPATIQCO thus assists the longitudinal monitoring of important QC metrics such as peptide elution times, peak widths, intensities, total ion current (TIC) as well as sensitivity, and overall LC-MS system performance; in this way the software also helps identify potential problems. The SIMPATIQCO software package is available free of charge.

  13. SIMPATIQCO: A Server-Based Software Suite Which Facilitates Monitoring the Time Course of LC–MS Performance Metrics on Orbitrap Instruments

    PubMed Central

    2012-01-01

    While the performance of liquid chromatography (LC) and mass spectrometry (MS) instrumentation continues to increase, applications such as analyses of complete or near-complete proteomes and quantitative studies require constant and optimal system performance. For this reason, research laboratories and core facilities alike are recommended to implement quality control (QC) measures as part of their routine workflows. Many laboratories perform sporadic quality control checks. However, successive and systematic longitudinal monitoring of system performance would be facilitated by dedicated automatic or semiautomatic software solutions that aid an effortless analysis and display of QC metrics over time. We present the software package SIMPATIQCO (SIMPle AuTomatIc Quality COntrol) designed for evaluation of data from LTQ Orbitrap, Q-Exactive, LTQ FT, and LTQ instruments. A centralized SIMPATIQCO server can process QC data from multiple instruments. The software calculates QC metrics supervising every step of data acquisition from LC and electrospray to MS. For each QC metric the software learns the range indicating adequate system performance from the uploaded data using robust statistics. Results are stored in a database and can be displayed in a comfortable manner from any computer in the laboratory via a web browser. QC data can be monitored for individual LC runs as well as plotted over time. SIMPATIQCO thus assists the longitudinal monitoring of important QC metrics such as peptide elution times, peak widths, intensities, total ion current (TIC) as well as sensitivity, and overall LC–MS system performance; in this way the software also helps identify potential problems. The SIMPATIQCO software package is available free of charge. PMID:23088386

  14. Comprehensive analysis of chemical constituents in Xingxiong injection by high performance liquid chromatography coupled with mass spectrometry.

    PubMed

    Guo, Long; Dou, Li-Li; Duan, Li; Liu, Ke; Bi, Zhi-Ming; Li, Ping; Liu, E-Hu

    2015-09-01

    Xingxiong injection (XXI) is a widely used Chinese herbal formula prepared by the folium ginkgo extract and ligustrazine for the treatment of cardiovascular and cerebrovascular diseases. Compared with the pharmacological studies, chemical analysis and quality control studies on this formula are relatively limited. In the present study, a high performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry (HPLC-QTOF MS) method was applied to comprehensive analysis of constituents in XXI. According to the fragmentation rules and previous reports, thirty ginkgo flavonoids, four ginkgo terpene lactones, and one alkaloid were identified. A high performance liquid chromatography coupled with triple quadrupole mass spectrometry (HPLC-QQQ MS) method was then applied to quantify ten major constituents in XXI. The method validation results indicated that the developed method had desirable specificity, linearity, precision and accuracy. The total contents of ginkgo flavonoids were about 22.05-25.51 μg·mL(-1) and the ginkgo terpene lactones amounts were about 4.41-8.70 μg·mL(-1) in six batches of XXI samples, respectively. Furthermore, cosine ratio algorithm and distance measurements were employed to evaluate the similarity of XXI samples, and the results demonstrated a high-quality consistency. This work could provide comprehensive information on the quality control of Xingxiong injection, which be helpful in the establishment of a rational quality control standard. Copyright © 2015 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.

  15. Simultaneous determination of six active components by a single standard to determine multicomponents combined with fingerprint analysis for the quality control of Rhizoma Chuanxiong.

    PubMed

    He, Yufei; Li, Qing; Bi, Kaishun

    2015-04-01

    To control the quality of Rhizoma Chuanxiong, a method based on high-performance liquid chromatography method coupled with diode array detection was developed for the quantitative analysis of six active ingredients using a single standard to determine multi-components and chemical fingerprint analysis for the first time. The separation was performed on an Agilent Zorbax SB-C18 column by gradient elution with methanol and aqueous phase (containing 0.5% glacial acetic acid) at a flow rate of 1.0 mL/min. The UV wavelength was set at 274 nm. This assay was fully validated with respect to precision, repeatability, and accuracy. All calibration curves showed good linearity (R(2) > 0.9994) within test ranges. The limit of detection and limit of quantification were lower than 0.01 and 0.03 μg/mL, respectively. The relative standard deviation for repeatability and the intermediate precision of six analytes were less than 1.6 and 2.5%, respectively, the overall recovery was 96.1-103.1%. In addition, fingerprint chromatography using hierarchical clustering analysis and similarity analysis was performed to differentiate and classify the samples. The method described here could provide a more comprehensive and reasonable scientific assessment of the quality of Rhizoma Chuanxiong. Therefore, the strategy is feasible, credible, and is easily and effectively adapted for evaluating the quality control of Rhizoma Chuanxiong. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Off-Line Quality Control In Integrated Circuit Fabrication Using Experimental Design

    NASA Astrophysics Data System (ADS)

    Phadke, M. S.; Kackar, R. N.; Speeney, D. V.; Grieco, M. J.

    1987-04-01

    Off-line quality control is a systematic method of optimizing production processes and product designs. It is widely used in Japan to produce high quality products at low cost. The method was introduced to us by Professor Genichi Taguchi who is a Deming-award winner and a former Director of the Japanese Academy of Quality. In this paper we will i) describe the off-line quality control method, and ii) document our efforts to optimize the process for forming contact windows in 3.5 Aim CMOS circuits fabricated in the Murray Hill Integrated Circuit Design Capability Laboratory. In the fabrication of integrated circuits it is critically important to produce contact windows of size very near the target dimension. Windows which are too small or too large lead to loss of yield. The off-line quality control method has improved both the process quality and productivity. The variance of the window size has been reduced by a factor of four. Also, processing time for window photolithography has been substantially reduced. The key steps of off-line quality control are: i) Identify important manipulatable process factors and their potential working levels. ii) Perform fractional factorial experiments on the process using orthogonal array designs. iii) Analyze the resulting data to determine the optimum operating levels of the factors. Both the process mean and the process variance are considered in this analysis. iv) Conduct an additional experiment to verify that the new factor levels indeed give an improvement.

  17. Value-based purchasing and hospital acquired conditions: are we seeing improvement?

    PubMed

    Spaulding, Aaron; Zhao, Mei; Haley, D Rob

    2014-12-01

    To determine if the Value-Based Purchasing Performance Scoring system correlates with hospital acquired condition quality indicators. This study utilizes the following secondary data sources: the American Hospital Association (AHA) annual survey and the Centers for Medicare and Medicaid (CMS) Value-Based Purchasing and Hospital Acquired Conditions databases. Zero-inflated negative binomial regression was used to examine the effect of CMS total performance score on counts of hospital acquired conditions. Hospital structure variables including size, ownership, teaching status, payer mix, case mix, and location were utilized as control variables. The secondary data sources were merged into a single database using Stata 10. Total performance scores, which are used to determine if hospitals should receive incentive money, do not correlate well with quality outcome in the form of hospital acquired conditions. Value-based purchasing does not appear to correlate with improved quality and patient safety as indicated by Hospital Acquired Condition (HAC) scores. This leads us to believe that either the total performance score does not measure what it should, or the quality outcome measurements do not reflect the quality of the total performance scores measure. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  18. Contrast-enhanced MR angiography of the chest and abdomen with use of controlled apnea in children.

    PubMed

    Saleh, Roya S; Patel, Swati; Lee, Margaret H; Boechat, M Ines; Ratib, Osman; Saraiva, Carla R; Finn, J Paul

    2007-06-01

    To retrospectively determine if controlled apnea improves the image quality of contrast material--enhanced magnetic resonance (MR) angiography of the chest and abdomen in children. Institutional review board approval and waiver of informed consent were obtained for this HIPAA-compliant study. The authors evaluated contrast-enhanced MR angiographic procedures performed in the chest, abdomen, or both, in 23 children (14 boys, nine girls; age range, 1 month to 8 years) who were under general anesthesia. All patients underwent mechanical ventilation with preoxygenation (100% oxygen) prior to controlled apnea during image acquisition. In control subjects, the authors assessed contrast-enhanced MR angiographic procedures performed in the chest, abdomen, or both, in 23 children (matched for age and type of study with children in the controlled apnea group; 11 boys, 12 girls; age range, 1 month to 8 years) who were under general anesthesia (n=15) or deep sedation (n=8) and were breathing spontaneously during image acquisition. MR angiograms of the chest, abdomen, or both, were assessed for image quality, motion artifacts, and vessel definition by two radiologists working in consensus with a subjective grading scale. Wilcoxon signed rank test was used to assess differences in measurements. Image quality was rated excellent in 97% (30 of 31) of studies with controlled apnea and in 30% (nine of 31) of control studies (P<.001). Motion artifacts were absent in 97% (30 of 31) of studies with controlled apnea and 13% (four of 31) of control studies (P<.001). Vessel sharpness was rated as being significantly better on images obtained with controlled apnea (P<.05). There were no complications caused by anesthesia or sedation in either group. Controlled apnea is highly effective in children for eliminating respiratory motion artifacts with contrast-enhanced MR angiographic studies, resulting in greatly improved image quality and spatial resolution. (c) RSNA, 2007.

  19. Function evaluation of asphalt mixture with industrially produced BOF slag aggregate.

    PubMed

    Zhao, Meiling; Wu, Shaopeng; Chen, Zongwu; Li, Chao

    2016-07-04

    Laboratory research suggested that basic oxygen furnace (BOF) slag-based asphalt mixture was a functional material. However, the BOF slag aggregate's quality was difficult to control when it was heavily used in entity engineering. The primary objective of this research was to evaluate the functional performances of asphalt mixture containing BOF slag coarse aggregate (BSCA), which was from an industrialized production line. Limestone mixture was a control group. The Marshall method was first adopted to design asphalt mixtures. The performances of limestone asphalt mixture and BOF slag asphalt mixture including fatigue failure resistance and moisture stability were then evaluated and compared. Results showed that the asphalt mixture containing BSCA possessed better durability, which meant the quality of BSCA from industrialized production lines was well controlled and this BSCA can be heavily used in entity engineering.

  20. Improving Service Delivery in a County Health Department WIC Clinic: An Application of Statistical Process Control Techniques

    PubMed Central

    Boe, Debra Thingstad; Parsons, Helen

    2009-01-01

    Local public health agencies are challenged to continually improve service delivery, yet they frequently operate with constrained resources. Quality improvement methods and techniques such as statistical process control are commonly used in other industries, and they have recently been proposed as a means of improving service delivery and performance in public health settings. We analyzed a quality improvement project undertaken at a local Special Supplemental Nutrition Program for Women, Infants, and Children (WIC) clinic to reduce waiting times and improve client satisfaction with a walk-in nutrition education service. We used statistical process control techniques to evaluate initial process performance, implement an intervention, and assess process improvements. We found that implementation of these techniques significantly reduced waiting time and improved clients' satisfaction with the WIC service. PMID:19608964

  1. A wavefront compensation approach to segmented mirror figure control

    NASA Technical Reports Server (NTRS)

    Redding, David; Breckenridge, Bill; Sevaston, George; Lau, Ken

    1991-01-01

    We consider the 'figure-control' problem for a spaceborn sub-millimeter wave telescope, the Precision Segmented Reflector Project Focus Mission Telescope. We show that performance of any figure control system is subject to limits on the controllability and observability of the quality of the wavefront. We present a wavefront-compensation method for the Focus Mission Telescope which uses mirror-figure sensors and three-axis segment actuator to directly minimize wavefront errors due to segment position errors. This approach shows significantly better performance when compared with a panel-state-compensation approach.

  2. Control Chart on Semi Analytical Weighting

    NASA Astrophysics Data System (ADS)

    Miranda, G. S.; Oliveira, C. C.; Silva, T. B. S. C.; Stellato, T. B.; Monteiro, L. R.; Marques, J. R.; Faustino, M. G.; Soares, S. M. V.; Ulrich, J. C.; Pires, M. A. F.; Cotrim, M. E. B.

    2018-03-01

    Semi-analytical balance verification intends to assess the balance performance using graphs that illustrate measurement dispersion, trough time, and to demonstrate measurements were performed in a reliable manner. This study presents internal quality control of a semi-analytical balance (GEHAKA BG400) using control charts. From 2013 to 2016, 2 weight standards were monitored before any balance operation. This work intended to evaluate if any significant difference or bias were presented on weighting procedure over time, to check the generated data reliability. This work also exemplifies how control intervals are established.

  3. Autonomous Quality Control of Joint Orientation Measured with Inertial Sensors.

    PubMed

    Lebel, Karina; Boissy, Patrick; Nguyen, Hung; Duval, Christian

    2016-07-05

    Clinical mobility assessment is traditionally performed in laboratories using complex and expensive equipment. The low accessibility to such equipment, combined with the emerging trend to assess mobility in a free-living environment, creates a need for body-worn sensors (e.g., inertial measurement units-IMUs) that are capable of measuring the complexity in motor performance using meaningful measurements, such as joint orientation. However, accuracy of joint orientation estimates using IMUs may be affected by environment, the joint tracked, type of motion performed and velocity. This study investigates a quality control (QC) process to assess the quality of orientation data based on features extracted from the raw inertial sensors' signals. Joint orientation (trunk, hip, knee, ankle) of twenty participants was acquired by an optical motion capture system and IMUs during a variety of tasks (sit, sit-to-stand transition, walking, turning) performed under varying conditions (speed, environment). An artificial neural network was used to classify good and bad sequences of joint orientation with a sensitivity and a specificity above 83%. This study confirms the possibility to perform QC on IMU joint orientation data based on raw signal features. This innovative QC approach may be of particular interest in a big data context, such as for remote-monitoring of patients' mobility.

  4. Minimum airflow reset of single-duct VAV terminal boxes

    NASA Astrophysics Data System (ADS)

    Cho, Young-Hum

    Single duct Variable Air Volume (VAV) systems are currently the most widely used type of HVAC system in the United States. When installing such a system, it is critical to determine the minimum airflow set point of the terminal box, as an optimally selected set point will improve the level of thermal comfort and indoor air quality (IAQ) while at the same time lower overall energy costs. In principle, this minimum rate should be calculated according to the minimum ventilation requirement based on ASHRAE standard 62.1 and maximum heating load of the zone. Several factors must be carefully considered when calculating this minimum rate. Terminal boxes with conventional control sequences may result in occupant discomfort and energy waste. If the minimum rate of airflow is set too high, the AHUs will consume excess fan power, and the terminal boxes may cause significant simultaneous room heating and cooling. At the same time, a rate that is too low will result in poor air circulation and indoor air quality in the air-conditioned space. Currently, many scholars are investigating how to change the algorithm of the advanced VAV terminal box controller without retrofitting. Some of these controllers have been found to effectively improve thermal comfort, indoor air quality, and energy efficiency. However, minimum airflow set points have not yet been identified, nor has controller performance been verified in confirmed studies. In this study, control algorithms were developed that automatically identify and reset terminal box minimum airflow set points, thereby improving indoor air quality and thermal comfort levels, and reducing the overall rate of energy consumption. A theoretical analysis of the optimal minimum airflow and discharge air temperature was performed to identify the potential energy benefits of resetting the terminal box minimum airflow set points. Applicable control algorithms for calculating the ideal values for the minimum airflow reset were developed and applied to actual systems for performance validation. The results of the theoretical analysis, numeric simulations, and experiments show that the optimal control algorithms can automatically identify the minimum rate of heating airflow under actual working conditions. Improved control helps to stabilize room air temperatures. The vertical difference in the room air temperature was lower than the comfort value. Measurements of room CO2 levels indicate that when the minimum airflow set point was reduced it did not adversely affect the indoor air quality. According to the measured energy results, optimal control algorithms give a lower rate of reheating energy consumption than conventional controls.

  5. Hospital implementation of health information technology and quality of care: are they related?

    PubMed

    Restuccia, Joseph D; Cohen, Alan B; Horwitt, Jedediah N; Shwartz, Michael

    2012-09-27

    Recently, there has been considerable effort to promote the use of health information technology (HIT) in order to improve health care quality. However, relatively little is known about the extent to which HIT implementation is associated with hospital patient care quality. We undertook this study to determine the association of various HITs with: hospital quality improvement (QI) practices and strategies; adherence to process of care measures; risk-adjusted inpatient mortality; patient satisfaction; and assessment of patient care quality by hospital quality managers and front-line clinicians. We conducted surveys of quality managers and front-line clinicians (physicians and nurses) in 470 short-term, general hospitals to obtain data on hospitals' extent of HIT implementation, QI practices and strategies, assessments of quality performance, commitment to quality, and sufficiency of resources for QI. Of the 470 hospitals, 401 submitted complete data necessary for analysis. We also developed measures of hospital performance from several publicly data available sources: Hospital Compare adherence to process of care measures; Medicare Provider Analysis and Review (MEDPAR) file; and Hospital Consumer Assessment of Healthcare Providers and Systems HCAHPS® survey. We used Poisson regression analysis to examine the association between HIT implementation and QI practices and strategies, and general linear models to examine the relationship between HIT implementation and hospital performance measures. Controlling for potential confounders, we found that hospitals with high levels of HIT implementation engaged in a statistically significant greater number of QI practices and strategies, and had significantly better performance on mortality rates, patient satisfaction measures, and assessments of patient care quality by hospital quality managers; there was weaker evidence of higher assessments of patient care quality by front-line clinicians. Hospital implementation of HIT was positively associated with activities intended to improve patient care quality and with higher performance on four of six performance measures.

  6. Implementation of high performance concrete in Louisiana bridges : interim report.

    DOT National Transportation Integrated Search

    1998-02-01

    The report contains a research plan to assist in the implementation of high performance concrete in the Charenton Canal Bridge in Louisiana. The research involves a literature review, plan review, development of a quality control program for the conc...

  7. Biobanking of CSF: international standardization to optimize biomarker development.

    PubMed

    Teunissen, Charlotte E; Tumani, Hayrettin; Engelborghs, Sebastiaan; Mollenhauer, Brit

    2014-03-01

    Cerebrospinal fluid (CSF) reflects pathophysiological aspects of neurological diseases, where neuroprotective strategies and biomarkers are urgently needed. Therefore, biobanking is very relevant for biomarker discovery and evaluation of neurological diseases. Important and unique features of CSF biobanking are intensive collaboration in international networks and the tight application of standardized protocols. The current adoption of standardized protocols for CSF and blood collection as presented in this review enables biomarker studies in large cohorts of patients and controls. Another topic of this review is the selection of control groups, which influences the outcome of biomarker investigations. Control groups in CSF biobanks mainly consist of different disease controls. This is in part due to the fact that lumbar punctures are mostly performed for clinical indications and rarely for research purposes only, as it is a relatively invasive procedure. Moreover, there is a lack of homogenous criteria and definition of control groups. We therefore propose uniform consensus definitions for such control groups in biomarker research, i.e. Healthy controls (HC), Spinal anesthesia subjects (SAS), Symptomatic controls (SC), Inflammatory Neurological Disease Controls (CINDC), Peripheral Inflammatory Neurological Disease Controls (PINDC) and Non-inflammatory Neurological Disease Controls (NINDC). Another important aspect of CSF biobanking is quality control. Systematic studies to address effects of pre-analytical and storage variation on a broad range of CSF proteins are needed. In conclusion, biomarker research in neurodegenerative diseases has entered a new era due to the collaborative and multicenter efforts of many groups. The streamlining of biobanking procedures, including quality control, and the selection of optimal control groups for investigating biomarkers are important improvements to perform high quality biomarker studies. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  8. Is the Web as good as the lab? Comparable performance from Web and lab in cognitive/perceptual experiments.

    PubMed

    Germine, Laura; Nakayama, Ken; Duchaine, Bradley C; Chabris, Christopher F; Chatterjee, Garga; Wilmer, Jeremy B

    2012-10-01

    With the increasing sophistication and ubiquity of the Internet, behavioral research is on the cusp of a revolution that will do for population sampling what the computer did for stimulus control and measurement. It remains a common assumption, however, that data from self-selected Web samples must involve a trade-off between participant numbers and data quality. Concerns about data quality are heightened for performance-based cognitive and perceptual measures, particularly those that are timed or that involve complex stimuli. In experiments run with uncompensated, anonymous participants whose motivation for participation is unknown, reduced conscientiousness or lack of focus could produce results that would be difficult to interpret due to decreased overall performance, increased variability of performance, or increased measurement noise. Here, we addressed the question of data quality across a range of cognitive and perceptual tests. For three key performance metrics-mean performance, performance variance, and internal reliability-the results from self-selected Web samples did not differ systematically from those obtained from traditionally recruited and/or lab-tested samples. These findings demonstrate that collecting data from uncompensated, anonymous, unsupervised, self-selected participants need not reduce data quality, even for demanding cognitive and perceptual experiments.

  9. Patient Navigators and Parent Use of Quality Data: A Randomized Trial.

    PubMed

    Goff, Sarah L; Mazor, Kathleen M; Pekow, Penelope S; White, Katharine O; Priya, Aruna; Lagu, Tara; Guhn-Knight, Haley; Murphy, Lorna; Youssef Budway, Yara; Lindenauer, Peter K

    2016-10-01

    Consumers rarely use publicly reported health care quality data. Despite known barriers to use, few studies have explored the effectiveness of strategies to overcome barriers in vulnerable populations. This randomized controlled trial tested the impact of a patient navigator intervention to increase consumer use of publicly reported quality data. Patients attending an urban prenatal clinic serving a vulnerable population enrolled between May 2013 and January 2015. The intervention consisted of 2 in-person sessions in which women learned about quality performance and viewed scores for local practices on the Massachusetts Health Quality Partners Web site. Women in both the intervention and control arms received a pamphlet about health care quality. Primary study outcomes were mean clinical quality and patient experience scores of the practices women selected (range 1-4 stars). Nearly all (726/746; 97.3%) women completed the study, 59.7% were Hispanic, and 65.1% had a high school education or less. In both unadjusted and adjusted models, women in the intervention group chose practices with modestly higher mean clinical quality (3.2 vs 3.0 stars; P = .001) and patient experience (3.0 vs 2.9 stars; P = .05) scores. When asked to rate what factors mattered the most in their decision, few cited quality scores. An intervention to reduce barriers to using publicly reported health care quality data had a modest effect on patient choice. These findings suggest that factors other than performance on common publicly reported quality metrics have a stronger influence on which pediatric practices women choose. Copyright © 2016 by the American Academy of Pediatrics.

  10. Sentinel-3 Mission Performance Center: paving the way of high-quality controlled data

    NASA Astrophysics Data System (ADS)

    Bruniquel, Jerome; Féménias, Pierre; Goryl, Philippe; Bonekamp, Hans

    2015-04-01

    As part of the Sentinel-3 mission and in order to ensure the highest quality of products, ESA and EUMETSAT set up the Sentinel-3 Mission Performance Centre (S-3 MPC). This facility is part of the Payload Data Ground Segment (PDGS) and aims at controlling the quality of all generated products, from L0 to L2. The S-3 MPC is composed of a Coordinating Centre (CC), where the core infrastructure is hosted, which is in charge of the main routine activities (especially the quality control of data) and the overall service management. Expert Support Laboratories (ESLs) are involved in calibration and validation activities and provide specific assessment of the products (e.g., analysis of trends, ad hoc analysis of anomalies, etc.). The S-3 MPC interacts with the Processing Archiving Centers (PACs) and the marine centre at EUMETSAT. The S-3 MPC service contract is currently carried out by 23-partners consortium led by ACRI-ST, France. The S-3 MPC contract was kick-offed in September 2014 with a first set-up phase of 12 months. After the launch of S3-A (planned before end of 2015), the S-3 MPC will start its second phase to support commissioning activities. Then a routine operation phase of up to 5 years will begin, including the commissioning activities related to S3-B. The main S-3 MPC activities are: - Calibration: to update on-board and on-ground configuration data in order to meet product quality requirements. - Validation: to assess, by independent means with respect to the methods and tools used for calibration, the quality of the generated data products. Validation functions provide feedback to calibration and data processors corrective and perfective maintenance activities. - Verification: to confirm that the specified requirements on a system have been satisfied. - Quality Control: to routinely monitor the status of the sensor and to check if the derived products (Level 0, Level 1 and Level 2) meet the quality requirements along mission lifetime. - Algorithm Maintenance and Evolution: to maintain the algorithm documentation baseline and to perform the necessary corrections/evolutions as agreed with the mission management and to validate them. - System performance monitoring: to monitor the end-to-end performance of the Sentinel-3 relevant system operations and assess them with respect to the operations plan. Due to the high volume of data and in order to facilitate the analysis to be performed by the expert scientists, an innovative facility is being implemented as part of the MPC/CC. We propose to all ESLs to use a collaborative platform which is a secured IT environment mixing hardware and software elements enabling users to work remotely. The main benefit is that they don't need to download huge amount of data by performing their processing and analysis where the products are located. First tests of the platform have been successfully done in last December. Note: The work performed in the frame of this contract is carried out with funding by the European Union. The views expressed herein can in no way be taken to reflect the official opinion of either the European Union or the European Space Agency.

  11. SeaWiFS Technical Report Series. Volume 38; SeaWiFS Calibration and Validation Quality Control Procedures

    NASA Technical Reports Server (NTRS)

    Hooker, Stanford B. (Editor); Firestone, Elaine R. (Editor); McClain, Charles R.; Darzi, Michael; Barnes, Robert A.; Eplee, Robert E.; Firestone, James K.; Patt, Frederick S.; Robinson, Wayne D.; Schieber, Brian D.; hide

    1996-01-01

    This document provides five brief reports that address several quality control procedures under the auspices of the Calibration and Validation Element (CVE) within the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Project. Chapter 1 describes analyses of the 32 sensor engineering telemetry streams. Anomalies in any of the values may impact sensor performance in direct or indirect ways. The analyses are primarily examinations of parameter time series combined with statistical methods such as auto- and cross-correlation functions. Chapter 2 describes how the various onboard (solar and lunar) and vicarious (in situ) calibration data will be analyzed to quantify sensor degradation, if present. The analyses also include methods for detecting the influence of charged particles on sensor performance such as might be expected in the South Atlantic Anomaly (SAA). Chapter 3 discusses the quality control of the ancillary environmental data that are routinely received from other agencies or projects which are used in the atmospheric correction algorithm (total ozone, surface wind velocity, and surface pressure; surface relative humidity is also obtained, but is not used in the initial operational algorithm). Chapter 4 explains the procedures for screening level-, level-2, and level-3 products. These quality control operations incorporate both automated and interactive procedures which check for file format errors (all levels), navigation offsets (level-1), mask and flag performance (level-2), and product anomalies (all levels). Finally, Chapter 5 discusses the match-up data set development for comparing SeaWiFS level-2 derived products with in situ observations, as well as the subsequent outlier analyses that will be used for evaluating error sources.

  12. Systematic review of coaching to enhance surgeons' operative performance.

    PubMed

    Min, Hyeyoun; Morales, Dianali Rivera; Orgill, Dennis; Smink, Douglas S; Yule, Steven

    2015-11-01

    There is increasing attention on the coaching of surgeons and trainees to improve performance but no comprehensive review on this topic. The purpose of this review is to summarize the quantity and the quality of studies involving surgical coaching methods and their effectiveness. We performed a systematic literature search through PubMed and PsychINFO by using predefined inclusion criteria. Evidence for main outcome categories was evaluated with the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) system and the Medical Education Research Study Quality Instrument (MERSQI). Of a total 3,063 articles, 23 met our inclusion criteria; 4 randomized controlled trials and 19 observational studies. We categorized the articles into 4 groups on the basis of the outcome studied: perception, attitude and opinion; technical skills; nontechnical skills; and performance measures. Overall strength of evidence for each outcome groups was as follows: Perception, attitude, and opinion (Grading of Recommendations Assessment, Development, and Evaluation: Very Low, Medical Education Research Study Quality Instrument [MERSQI]: 10); technical skills (randomized controlled trials: High, 13.1; Observation studies: Very Low, 11.5); nontechnical skills (Very Low, 12.4) and performance measures (Very Low, 13.6). Simulation was the most used setting for coaching; more than half of the studies deployed an experienced surgeon as a coach and showed that coaching was effective. Surgical coaching interventions have a positive impact on learners' perception and attitudes, their technical and nontechnical skills, and performance measures. Evidence of impact on patient outcomes was limited, and the quality of research studies was variable. Despite this, our systematic review of different coaching interventions will benefit future coaching strategies and implementation to enhance operative performance. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. A piloted simulation of helicopter air combat to investigate effects of variations in selected performance and control response characteristics

    NASA Technical Reports Server (NTRS)

    Lewis, Michael S.; Mansur, M. Hossein; Chen, Robert T. N.

    1987-01-01

    A piloted simulation study investigating handling qualities and flight characteristics required for helicopter air to air combat is presented. The Helicopter Air Combat system was used to investigate this role for Army rotorcraft. Experimental variables were the maneuver envelope size (load factor and sideslip), directional axis handling qualities, and pitch and roll control-response type. Over 450 simulated, low altitude, one-on-one engagements were conducted. Results from the experiment indicate that a well damped directional response, low sideforce caused by sideslip, and some effective dihedral are all desirable for weapon system performance, good handling qualities, and low pilot workload. An angular rate command system was favored over the attitude type pitch and roll response for most applications, and an enhanced maneuver envelope size over that of current generation aircraft was found to be advantageous. Pilot technique, background, and experience are additional factors which had a significant effect on performance in the air combat tasks investigated. The implication of these results on design requirements for future helicopters is presented.

  14. [Application of fingerprint chromatogram in quality control of Shen-Mai injection].

    PubMed

    Shi, Xian-zhe; Yang, Jun; Zhao, Chun-xia; Xiong, Jian-hui; Xu, Guo-wang

    2002-07-01

    The theory and practice of traditional Chinese medicine require some comprehensive methods to assess quality of the Chinese herbal medication. Fingerprint chromatogram is one of the feasible approaches to evaluate the quality of Chinese herbal medication. So the fingerprint chromatogram of Shen-Mai injection was established by using reversed-phase high performance liquid chromatography. The chromatographic conditions were as follows: a Hypersil C18 column was used; the mobile phase was composed of water (A) and acetontrile (B) with linear gradient elution (0-50 min, 5%-95% B, volume fraction); the flow rate was 1.0 mL/min and the UV absorbance detection was set at 202 nm. The peak-area ratios of twenty-three fingerprint peaks and internal standard (diphenyl) were taken as the criteria for quality control. The quality differences in various batches and various manufacturers of Shen-Mai injections were investigated by projection discriminance based on principal component analysis. The results show the method developed is convenient, reliable and applicable for the quality control analysis of Shen-Mai injection.

  15. Do Clinical Standards for Diabetes Care Address Excess Risk for Hypoglycemia in Vulnerable Patients? A Systematic Review

    PubMed Central

    Berkowitz, Seth A; Aragon, Katherine; Hines, Jonas; Seligman, Hilary; Lee, Sei; Sarkar, Urmimala

    2013-01-01

    Objective To determine whether diabetes clinical standards consider increased hypoglycemia risk in vulnerable patients. Data Sources MEDLINE, the National Guidelines Clearinghouse, the National Quality Measures Clearinghouse, and supplemental sources. Study Design Systematic review of clinical standards (guidelines, quality metrics, or pay-for-performance programs) for glycemic control in adult diabetes patients. The primary outcome was discussion of increased risk for hypoglycemia in vulnerable populations. Data Collection/Extraction Methods Manuscripts identified were abstracted by two independent reviewers using prespecified inclusion/exclusion criteria and a standardized abstraction form. Principal Findings We screened 1,166 titles, and reviewed 220 manuscripts in full text. Forty-four guidelines, 17 quality metrics, and 8 pay-for-performance programs were included. Five (11 percent) guidelines and no quality metrics or pay-for-performance programs met the primary outcome. Conclusions Clinical standards do not substantively incorporate evidence about increased risk for hypoglycemia in vulnerable populations. PMID:23445498

  16. Do clinical standards for diabetes care address excess risk for hypoglycemia in vulnerable patients? A systematic review.

    PubMed

    Berkowitz, Seth A; Aragon, Katherine; Hines, Jonas; Seligman, Hilary; Lee, Sei; Sarkar, Urmimala

    2013-08-01

    To determine whether diabetes clinical standards consider increased hypoglycemia risk in vulnerable patients. MEDLINE, the National Guidelines Clearinghouse, the National Quality Measures Clearinghouse, and supplemental sources. Systematic review of clinical standards (guidelines, quality metrics, or pay-for-performance programs) for glycemic control in adult diabetes patients. The primary outcome was discussion of increased risk for hypoglycemia in vulnerable populations. Manuscripts identified were abstracted by two independent reviewers using prespecified inclusion/exclusion criteria and a standardized abstraction form. We screened 1,166 titles, and reviewed 220 manuscripts in full text. Forty-four guidelines, 17 quality metrics, and 8 pay-for-performance programs were included. Five (11 percent) guidelines and no quality metrics or pay-for-performance programs met the primary outcome. Clinical standards do not substantively incorporate evidence about increased risk for hypoglycemia in vulnerable populations. © Health Research and Educational Trust.

  17. Preferences for technology versus human assistance and control over technology in the performance of kitchen and personal care tasks in baby boomers and older adults.

    PubMed

    Beach, Scott R; Schulz, Richard; Matthews, Judith T; Courtney, Karen; Dabbs, Annette DeVito

    2014-11-01

    Quality of Life technology (QoLT) stresses humans and technology as mutually dependent and aware, working together to improve task performance and quality of life. This study examines preferences for technology versus human assistance and control in the context of QoLT. Data are from a nationally representative, cross-sectional web-based sample of 416 US baby boomers (45-64) and 114 older adults (65+) on preferences for technology versus human assistance and control in the performance of kitchen and personal care tasks. Multinomial logistic regression and ordinary least squares regression were used to determine predictors of these preferences. Respondents were generally accepting of technology assistance but wanted to maintain control over its' operation. Baby boomers were more likely to prefer technology than older adults, and those with fewer QoLT privacy concerns and who thought they were more likely to need future help were more likely to prefer technology over human assistance and more willing to relinquish control to technology. Results suggest the need for design of person- and context-aware QoLT systems that are responsive to user desires for level of control over operation of the technology. The predictors of these preferences suggest potentially receptive markets for the targeting of QoLT systems.

  18. ASVCP guidelines: quality assurance for point-of-care testing in veterinary medicine.

    PubMed

    Flatland, Bente; Freeman, Kathleen P; Vap, Linda M; Harr, Kendal E

    2013-12-01

    Point-of-care testing (POCT) refers to any laboratory testing performed outside the conventional reference laboratory and implies close proximity to patients. Instrumental POCT systems consist of small, handheld or benchtop analyzers. These have potential utility in many veterinary settings, including private clinics, academic veterinary medical centers, the community (eg, remote area veterinary medical teams), and for research applications in academia, government, and industry. Concern about the quality of veterinary in-clinic testing has been expressed in published veterinary literature; however, little guidance focusing on POCT is available. Recognizing this void, the ASVCP formed a subcommittee in 2009 charged with developing quality assurance (QA) guidelines for veterinary POCT. Guidelines were developed through literature review and a consensus process. Major recommendations include (1) taking a formalized approach to POCT within the facility, (2) use of written policies, standard operating procedures, forms, and logs, (3) operator training, including periodic assessment of skills, (4) assessment of instrument analytical performance and use of both statistical quality control and external quality assessment programs, (5) use of properly established or validated reference intervals, (6) and ensuring accurate patient results reporting. Where possible, given instrument analytical performance, use of a validated 13s control rule for interpretation of control data is recommended. These guidelines are aimed at veterinarians and veterinary technicians seeking to improve management of POCT in their clinical or research setting, and address QA of small chemistry and hematology instruments. These guidelines are not intended to be all-inclusive; rather, they provide a minimum standard for maintenance of POCT instruments in the veterinary setting. © 2013 American Society for Veterinary Clinical Pathology and European Society for Veterinary Clinical Pathology.

  19. [Quality control of Guci tablets using UPLC-ELSD fingerprint analysis coupled with chemometrics].

    PubMed

    Wang, Ya-Dan; Dai, Zhong; Sun, Cai-Lin; Wu, Xian-Fu; Ma, Shuang-Cheng

    2018-03-01

    Ultra-performance liquid chromatography-evaporative light scattering detection (UPLC-ELSD) fingerprint analysis method was established for quality control of Guci tablets. Chromatographic separation was performed on Waters Acquity UPLC BEH C₁₈ column (2.1 mm×100 mm, 1.7 μm) at 30 °C of column temperature. Acetonitrile-0.1% formic acid solution was adopted as mobile phase for gradient elution. The flow rate was set at 0.3 mL·min⁻¹, and the injection volume was 3 μL. Detection was carried out on an ELSD with a nitrogen pressure of 0.28 MPa, drift tube temperature of 60 °C, and gain of 400. A total of 39 batches of samples produced by six manufacturers were measured by using the above method and the data were analyzed by ChemPattern software. The peak present in more than 75% of the samples was defined as a common peak, and 30 common peaks were determined. Among them, 19 peaks were identified by rapid resolution liquid chromatography/tandem mass spectrometry (RRLC-MS/MS) method, 16 of which were confirmed by reference substances. The similarity of the tested samples was 0.47-0.98, suggesting that the quality of the samples from different manufacturers varied greatly. Furthermore, principal component analysis (PCA) and hierarchical analysis (HCA) were performed to clarify the main different components in samples. The results indicated that there might be some feeding problems about Paeoniae Radix Alba, Notoginseng Radix et Rhizoma, and Clematidis Radix et Rhizoma in a few manufacturers. This study provided some evidences for the overall quality control of Guci tablets, as well as its quality standard improvements. Copyright© by the Chinese Pharmaceutical Association.

  20. The Effect of Performance-Based Financial Incentives on Improving Health Care Provision in Burundi: A Controlled Cohort Study

    PubMed Central

    Rudasingwa, Martin; Soeters, Robert; Bossuyt, Michel

    2015-01-01

    To strengthen the health care delivery, the Burundian Government in collaboration with international NGOs piloted performance-based financing (PBF) in 2006. The health facilities were assigned - by using a simple matching method - to begin PBF scheme or to continue with the traditional input-based funding. Our objective was to analyse the effect of that PBF scheme on the quality of health services between 2006 and 2008. We conducted the analysis in 16 health facilities with PBF scheme and 13 health facilities without PBF scheme. We analysed the PBF effect by using 58 composite quality indicators of eight health services: Care management, outpatient care, maternity care, prenatal care, family planning, laboratory services, medicines management and materials management. The differences in quality improvement in the two groups of health facilities were performed applying descriptive statistics, a paired non-parametric Wilcoxon Signed Ranks test and a simple difference-in-difference approach at a significance level of 5%. We found an improvement of the quality of care in the PBF group and a significant deterioration in the non-PBF group in the same four health services: care management, outpatient care, maternity care, and prenatal care. The findings suggest a PBF effect of between 38 and 66 percentage points (p<0.001) in the quality scores of care management, outpatient care, prenatal care, and maternal care. We found no PBF effect on clinical support services: laboratory services, medicines management, and material management. The PBF scheme in Burundi contributed to the improvement of the health services that were strongly under the control of medical personnel (physicians and nurses) in a short time of two years. The clinical support services that did not significantly improved were strongly under the control of laboratory technicians, pharmacists and non-medical personnel. PMID:25948432

  1. Standard Free Droplet Digital Polymerase Chain Reaction as a New Tool for the Quality Control of High-Capacity Adenoviral Vectors in Small-Scale Preparations

    PubMed Central

    Boehme, Philip; Stellberger, Thorsten; Solanki, Manish; Zhang, Wenli; Schulz, Eric; Bergmann, Thorsten; Liu, Jing; Doerner, Johannes; Baiker, Armin E.

    2015-01-01

    Abstract High-capacity adenoviral vectors (HCAdVs) are promising tools for gene therapy as well as for genetic engineering. However, one limitation of the HCAdV vector system is the complex, time-consuming, and labor-intensive production process and the following quality control procedure. Since HCAdVs are deleted for all viral coding sequences, a helper virus (HV) is needed in the production process to provide the sequences for all viral proteins in trans. For the purification procedure of HCAdV, cesium chloride density gradient centrifugation is usually performed followed by buffer exchange using dialysis or comparable methods. However, performing these steps is technically difficult, potentially error-prone, and not scalable. Here, we establish a new protocol for small-scale production of HCAdV based on commercially available adenovirus purification systems and a standard method for the quality control of final HCAdV preparations. For titration of final vector preparations, we established a droplet digital polymerase chain reaction (ddPCR) that uses a standard free-end-point PCR in small droplets of defined volume. By using different probes, this method is capable of detecting and quantifying HCAdV and HV in one reaction independent of reference material, rendering this method attractive for accurately comparing viral titers between different laboratories. In summary, we demonstrate that it is possible to produce HCAdV in a small scale of sufficient quality and quantity to perform experiments in cell culture, and we established a reliable protocol for vector titration based on ddPCR. Our method significantly reduces time and required equipment to perform HCAdV production. In the future the ddPCR technology could be advantageous for titration of other viral vectors commonly used in gene therapy. PMID:25640117

  2. [Analytical quality in biological monitoring of workers exposed to chemicals: experience of the Prevention and Safety at the Workplace Service in Modena].

    PubMed

    Alpaca, R I Paredes; Migliore, A; Di Rico, R; Canali, Claudia; Rota, Cristina; Trenti, T; Cariani, Elisabetta

    2010-01-01

    The quality of laboratory data is one of the main factors in guaranteeing efficacy of biological monitoring. To analyze the quality of laboratory data used for biological monitoring of exposed workers. A survey involving 18 companies employing 945 workers in the area of Modena, Italy, was carried out in 2008. Most of the 9 private laboratories receiving biological samples did not perform directly part or all of the laboratory assessments requested, but this was not indicated in the final report. Major problems were observed in the application of internal quality control, and only one laboratory participated in external quality assessment for blood lead measurements. Our results raise major concerns on the traceability and reliability of laboratory assessments performed for biomonitoring of exposed workers. Systematic evaluation of the quality of analytical data would be highly recommendable.

  3. [Standardization in laboratory hematology by participating in external quality assurance programs].

    PubMed

    Nazor, Aida; Siftar, Zoran; Flegar-Mestrić, Zlata

    2011-09-01

    Since 1985, Department of Clinical Chemistry and Laboratory Medicine, Merkur University Hospital, Zagreb, has been participating in the International External Quality Assessment Scheme for Hematology (IEQAS-H) organized by the World Health Organization (WHO). Owing to very good results, in 1987 the Department received a certificate of participation in this control scheme. Department has been cooperating in the external quality assessment program in laboratory hematology which has been continuously performed in Croatia since 1986 by the Committee for External Quality Assessment Schemes under the auspices of the Croatian Society of Medical Biochemists and School of Pharmacy and Biochemistry, University of Zagreb. Nowadays, 186 medical biochemical laboratories are included in the National External Quality Assessment program, which is performed three times per year. Our Department has participated in the international projects of the European Committee for External Quality Assurance Programs in Laboratory Medicine (EQALM).

  4. The effects of single-sex compared with coeducational schooling on students' performance and attitudes: a meta-analysis.

    PubMed

    Pahlke, Erin; Hyde, Janet Shibley; Allison, Carlie M

    2014-07-01

    Proponents of single-sex (SS) education believe that separating boys and girls, by classrooms or schools, increases students' achievement and academic interest. In this article, we use meta-analysis to analyze studies that have tested the effects on students of SS compared with coeducational (CE) schooling. We meta-analyzed data from 184 studies, representing the testing of 1.6 million students in Grades K-12 from 21 nations, for multiple outcomes (e.g., mathematics performance, mathematics attitudes, science performance, educational aspirations, self-concept, gender stereotyping). To address concerns about the quality of research designs, we categorized studies as uncontrolled (no controls for selection effects, no random assignment) or controlled (random assignment or controls for selection effects). Based on mixed-effects analyses, uncontrolled studies showed some modest advantages for single-sex schooling, for both girls and boys, for outcomes such as mathematics performance but not for science performance. Controlled studies, however, showed only trivial differences between students in SS versus CE, for mathematics performance (g = 0.10 for girls, 0.06 for boys) and science performance (g = 0.06 for girls, 0.04 for boys), and in some cases showed small differences favoring CE schooling (e.g., for girls' educational aspirations, g = -0.26). Separate analyses of U.S. studies yielded similar findings (e.g., for mathematics performance g = 0.14 for girls and 0.14 for boys). Results from the highest quality studies, then, do not support the view that SS schooling provides benefits compared with CE schooling. Claims that SS schooling is particularly effective for U.S. ethnic minority boys could not be tested due to the lack of controlled studies on this question. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  5. An Application of Six Sigma to Reduce Supplier Quality Cost

    NASA Astrophysics Data System (ADS)

    Gaikwad, Lokpriya Mohanrao; Teli, Shivagond Nagappa; Majali, Vijay Shashikant; Bhushi, Umesh Mahadevappa

    2016-01-01

    This article presents an application of Six Sigma to reduce supplier quality cost in manufacturing industry. Although there is a wider acceptance of Six Sigma in many organizations today, there is still a lack of in-depth case study of Six Sigma. For the present research the case study methodology was used. The company decided to reduce quality cost and improve selected processes using Six Sigma methodologies. Regarding the fact that there is a lack of case studies dealing with Six Sigma especially in individual manufacturing organization this article could be of great importance also for the practitioners. This paper discusses the quality and productivity improvement in a supplier enterprise through a case study. The paper deals with an application of Six Sigma define-measure-analyze-improve-control methodology in an industry which provides a framework to identify, quantify and eliminate sources of variation in an operational process in question, to optimize the operation variables, improve and sustain performance viz. process yield with well-executed control plans. Six Sigma improves the process performance (process yield) of the critical operational process, leading to better utilization of resources, decreases variations and maintains consistent quality of the process output.

  6. Testing the quality of images for permanent magnet desktop MRI systems using specially designed phantoms.

    PubMed

    Qiu, Jianfeng; Wang, Guozhu; Min, Jiao; Wang, Xiaoyan; Wang, Pengcheng

    2013-12-21

    Our aim was to measure the performance of desktop magnetic resonance imaging (MRI) systems using specially designed phantoms, by testing imaging parameters and analysing the imaging quality. We designed multifunction phantoms with diameters of 18 and 60 mm for desktop MRI scanners in accordance with the American Association of Physicists in Medicine (AAPM) report no. 28. We scanned the phantoms with three permanent magnet 0.5 T desktop MRI systems, measured the MRI image parameters, and analysed imaging quality by comparing the data with the AAPM criteria and Chinese national standards. Image parameters included: resonance frequency, high contrast spatial resolution, low contrast object detectability, slice thickness, geometrical distortion, signal-to-noise ratio (SNR), and image uniformity. The image parameters of three desktop MRI machines could be measured using our specially designed phantoms, and most parameters were in line with MRI quality control criterion, including: resonance frequency, high contrast spatial resolution, low contrast object detectability, slice thickness, geometrical distortion, image uniformity and slice position accuracy. However, SNR was significantly lower than in some references. The imaging test and quality control are necessary for desktop MRI systems, and should be performed with the applicable phantom and corresponding standards.

  7. Perception of synthetic speech produced automatically by rule: Intelligibility of eight text-to-speech systems

    PubMed Central

    GREENE, BETH G.; LOGAN, JOHN S.; PISONI, DAVID B.

    2012-01-01

    We present the results of studies designed to measure the segmental intelligibility of eight text-to-speech systems and a natural speech control, using the Modified Rhyme Test (MRT). Results indicated that the voices tested could be grouped into four categories: natural speech, high-quality synthetic speech, moderate-quality synthetic speech, and low-quality synthetic speech. The overall performance of the best synthesis system, DECtalk-Paul, was equivalent to natural speech only in terms of performance on initial consonants. The findings are discussed in terms of recent work investigating the perception of synthetic speech under more severe conditions. Suggestions for future research on improving the quality of synthetic speech are also considered. PMID:23225916

  8. Effect of e-learning and repeated performance feedback on spirometry test quality in family practice: a cluster trial.

    PubMed

    Schermer, Tjard R; Akkermans, Reinier P; Crockett, Alan J; van Montfort, Marian; Grootens-Stekelenburg, Joke; Stout, Jim W; Pieters, Willem

    2011-01-01

    Spirometry has become an indispensable tool in primary care to exclude, diagnose, and monitor chronic respiratory conditions, but the quality of spirometry tests in family practices is a reason for concern. Aim of this study was to investigate whether a combination of e-learning and bimonthly performance feedback would improve spirometry test quality in family practices in the course of 1 year. Our study was a cluster trial with 19 family practices allocated to intervention or control conditions through minimization. Intervention consisted of e-learning and bimonthly feedback reports to practice nurses. Control practices received only the joint baseline workshop. Spirometry quality was assessed by independent lung function technicians. Two outcomes were defined, with the difference between rates of tests with 2 acceptable and repeatable blows being the primary outcome and the difference between rates of tests with 2 acceptable blows being the secondary outcome. We used multilevel logistic regression analysis to calculate odds ratios (ORs) for an adequate test in intervention group practices. We analyzed 1,135 tests. Rate of adequate tests was 33% in intervention and 30% in control group practices (OR = 1.3; P=.605). Adequacy of tests did not differ between groups but tended to increase with time: OR = 2.2 (P = .057) after 3 and OR = 2.0 (P = .086) in intervention group practices after 4 feedback reports. When ignoring test repeatability, these differences between the groups were slightly more pronounced: OR = 2.4 (P = .033) after 3 and OR=2.2 (P = .051) after 4 feedback reports. In the course of 1 year, we observed a small and late effect of e-learning and repeated feedback on the quality of spirometry as performed by family practice nurses. This intervention does not seem to compensate the lack of rigorous training and experience in performing spirometry tests in most practices.

  9. Routing UAVs to Co-Optimize Mission Effectiveness and Network Performance with Dynamic Programming

    DTIC Science & Technology

    2011-03-01

    Heuristics on Hexagonal Connected Dominating Sets to Model Routing Dissemination," in Communication Theory, Reliability, and Quality of Service (CTRQ...24] Matthew Capt. USAF Compton, Improving the Quality of Service and Security of Military Networks with a Network Tasking Order Process, 2010. [25...Wesley, 2006. [32] James Haught, "Adaptive Quality of Service Engine with Dynamic Queue Control," Air Force Institute of Technology, Wright

  10. Quality control of EUVE databases

    NASA Technical Reports Server (NTRS)

    John, L. M.; Drake, J.

    1992-01-01

    The publicly accessible databases for the Extreme Ultraviolet Explorer include: the EUVE Archive mailserver; the CEA ftp site; the EUVE Guest Observer Mailserver; and the Astronomical Data System node. The EUVE Performance Assurance team is responsible for verifying that these public EUVE databases are working properly, and that the public availability of EUVE data contained therein does not infringe any data rights which may have been assigned. In this poster, we describe the Quality Assurance (QA) procedures we have developed from the approach of QA as a service organization, thus reflecting the overall EUVE philosophy of Quality Assurance integrated into normal operating procedures, rather than imposed as an external, post facto, control mechanism.

  11. Quality assurance and control in the production and static tests of the solid rocket boosters for the Space Shuttle

    NASA Technical Reports Server (NTRS)

    Cerny, O. F.

    1979-01-01

    The paper surveys the various aspects of design and overhaul of the solid rocket boosters. It is noted that quality control is an integral part of the design specifications. Attention is given to the production process which is optimized towards highest quality. Also discussed is the role of the DCA (Defense Contract Administration) in inspecting the products of subcontractors, noting that the USAF performs this role for prime contractors. Fabrication and construction of the booster is detailed with attention given to the lining of the booster cylinder and the mixing of the propellant and the subsequent X-ray inspection.

  12. Convenient and Efficient Method for Quality Control Analysis of 18F-Fluorocholine: For a Small Scale GMP-based Radiopharmaceuticals Laboratory Set-up.

    PubMed

    Hassan, Hishar; Abu Bakar, Suharzelim; Halim, Khairul Najah Che A; Idris, Jaleezah; Nordin, Abdul Jalil

    2016-01-01

    Prostate cancer continues to be the most prevalent cancer in men in Malaysia. As time progresses, the prospect of PET imaging modality in diagnosis of prostate cancer is promising, with on-going improvement on novel tracers. Among all tracers, 18F-Fluorocholine is reported to be a reputable tracer and reliable diagnostic technique for prostate imaging. Nonetheless, only 18F-Fluorodeoxyglucose (18F-FDG) is available and used in most oncology cases in Malaysia. With a small scale GMP-based radiopharmaceuticals laboratory set-up, initial efforts have been taken to put Malaysia on 18F-Fluorocholine map. This article presents a convenient, efficient and reliable method for quality control analysis of 18F-Fluorocholine. Besides, the aim of this research work is to assist local GMP radiopharmaceuticals laboratories and local authority in Malaysia for quality control analysis of 18F-Fluorocholine guideline. In this study, prior to synthesis, quality control analysis method for 18F-Fluorocholine was developed and validated, by adapting the equipment set-up used in 18F-Fluorodeoxyglucose (18FFDG) routine production. Quality control on the 18F-Fluorocholine was performed by means of pH, radionuclidic identity, radio-high performance liquid chromatography equipped with ultraviolet, radio- thin layer chromatography, gas chromatography and filter integrity test. Post-synthesis; the pH of 18F-Fluorocholine was 6.42 ± 0.04, with half-life of 109.5 minutes (n = 12). The radiochemical purity was consistently higher than 99%, both in radio-high performance liquid chromatography equipped with ultraviolet (r-HPLC; SCX column, 0.25 M NaH2PO4: acetonitrile) and radio-thin layer chromatography method (r-TLC). The calculated relative retention time (RRT) in r-HPLC was 1.02, whereas the retention factor (Rf) in r-TLC was 0.64. Potential impurities from 18F-Fluorocholine synthesis such as ethanol, acetonitrile, dimethylethanolamine and dibromomethane were determined in gas chromatography. Using our parameters, (capillary column: DB-200, 30 m x 0.53 mm x 1 um) and oven temperature of 35°C (isothermal), all compounds were well resolved and eluted within 3 minutes. Level of ethanol and acetonitrile in 18F-Fluorocholine were detected below threshold limit; less than 5 mg/ml and 0.41 mg/ml respectively. Meanwhile, dimethylethanolamine and dibromomethane were undetectable. A convenient, efficient and reliable quality control analysis work-up procedure for 18FFluorocholine has been established and validated to comply all the release criteria. The convenient method of quality control analysis may provide a guideline to local GMP radiopharmaceutical laboratories to start producing 18F-Fluorocholine as a tracer for prostate cancer imaging.

  13. Halogenated peptides as internal standards (H-PINS): introduction of an MS-based internal standard set for liquid chromatography-mass spectrometry.

    PubMed

    Mirzaei, Hamid; Brusniak, Mi-Youn; Mueller, Lukas N; Letarte, Simon; Watts, Julian D; Aebersold, Ruedi

    2009-08-01

    As the application for quantitative proteomics in the life sciences has grown in recent years, so has the need for more robust and generally applicable methods for quality control and calibration. The reliability of quantitative proteomics is tightly linked to the reproducibility and stability of the analytical platforms, which are typically multicomponent (e.g. sample preparation, multistep separations, and mass spectrometry) with individual components contributing unequally to the overall system reproducibility. Variations in quantitative accuracy are thus inevitable, and quality control and calibration become essential for the assessment of the quality of the analyses themselves. Toward this end, the use of internal standards cannot only assist in the detection and removal of outlier data acquired by an irreproducible system (quality control) but can also be used for detection of changes in instruments for their subsequent performance and calibration. Here we introduce a set of halogenated peptides as internal standards. The peptides are custom designed to have properties suitable for various quality control assessments, data calibration, and normalization processes. The unique isotope distribution of halogenated peptides makes their mass spectral detection easy and unambiguous when spiked into complex peptide mixtures. In addition, they were designed to elute sequentially over an entire aqueous to organic LC gradient and to have m/z values within the commonly scanned mass range (300-1800 Da). In a series of experiments in which these peptides were spiked into an enriched N-glycosite peptide fraction (i.e. from formerly N-glycosylated intact proteins in their deglycosylated form) isolated from human plasma, we show the utility and performance of these halogenated peptides for sample preparation and LC injection quality control as well as for retention time and mass calibration. Further use of the peptides for signal intensity normalization and retention time synchronization for selected reaction monitoring experiments is also demonstrated.

  14. Halogenated Peptides as Internal Standards (H-PINS)

    PubMed Central

    Mirzaei, Hamid; Brusniak, Mi-Youn; Mueller, Lukas N.; Letarte, Simon; Watts, Julian D.; Aebersold, Ruedi

    2009-01-01

    As the application for quantitative proteomics in the life sciences has grown in recent years, so has the need for more robust and generally applicable methods for quality control and calibration. The reliability of quantitative proteomics is tightly linked to the reproducibility and stability of the analytical platforms, which are typically multicomponent (e.g. sample preparation, multistep separations, and mass spectrometry) with individual components contributing unequally to the overall system reproducibility. Variations in quantitative accuracy are thus inevitable, and quality control and calibration become essential for the assessment of the quality of the analyses themselves. Toward this end, the use of internal standards cannot only assist in the detection and removal of outlier data acquired by an irreproducible system (quality control) but can also be used for detection of changes in instruments for their subsequent performance and calibration. Here we introduce a set of halogenated peptides as internal standards. The peptides are custom designed to have properties suitable for various quality control assessments, data calibration, and normalization processes. The unique isotope distribution of halogenated peptides makes their mass spectral detection easy and unambiguous when spiked into complex peptide mixtures. In addition, they were designed to elute sequentially over an entire aqueous to organic LC gradient and to have m/z values within the commonly scanned mass range (300–1800 Da). In a series of experiments in which these peptides were spiked into an enriched N-glycosite peptide fraction (i.e. from formerly N-glycosylated intact proteins in their deglycosylated form) isolated from human plasma, we show the utility and performance of these halogenated peptides for sample preparation and LC injection quality control as well as for retention time and mass calibration. Further use of the peptides for signal intensity normalization and retention time synchronization for selected reaction monitoring experiments is also demonstrated. PMID:19411281

  15. Design of permanent magnet synchronous motor speed loop controller based on sliding mode control algorithm

    NASA Astrophysics Data System (ADS)

    Qiang, Jiang; Meng-wei, Liao; Ming-jie, Luo

    2018-03-01

    Abstract.The control performance of Permanent Magnet Synchronous Motor will be affected by the fluctuation or changes of mechanical parameters when PMSM is applied as driving motor in actual electric vehicle,and external disturbance would influence control robustness.To improve control dynamic quality and robustness of PMSM speed control system, a new second order integral sliding mode control algorithm is introduced into PMSM vector control.The simulation results show that, compared with the traditional PID control,the modified control scheme optimized has better control precision and dynamic response ability and perform better with a stronger robustness facing external disturbance,it can effectively solve the traditional sliding mode variable structure control chattering problems as well.

  16. A Machine Vision Quality Control System for Industrial Acrylic Fibre Production

    NASA Astrophysics Data System (ADS)

    Heleno, Paulo; Davies, Roger; Correia, Bento A. Brázio; Dinis, João

    2002-12-01

    This paper describes the implementation of INFIBRA, a machine vision system used in the quality control of acrylic fibre production. The system was developed by INETI under a contract with a leading industrial manufacturer of acrylic fibres. It monitors several parameters of the acrylic production process. This paper presents, after a brief overview of the system, a detailed description of the machine vision algorithms developed to perform the inspection tasks unique to this system. Some of the results of online operation are also presented.

  17. Automated quality control for stitching of textile articles

    NASA Technical Reports Server (NTRS)

    Miller, Jeffrey L. (Inventor); Markus, Alan (Inventor)

    1999-01-01

    Quality control for stitching of a textile article is performed by measuring thread tension in the stitches as the stitches are being made, determining locations of the stitches, and generating a map including the locations and stitching data derived from the measured thread tensions. The stitching data can be analyzed, off-line or in real time, to identify defective stitches. Defective stitches can then be repaired. Real time analysis of the thread tensions allows problems such as broken needle threads to be corrected immediately.

  18. An index approach to performance-based payments for water quality.

    PubMed

    Maille, Peter; Collins, Alan R

    2012-05-30

    In this paper we describe elements of a field research project that presented farmers with economic incentives to control nitrate runoff. The approach used is novel in that payments are based on ambient water quality and water quantity produced by a watershed rather than proxies for water quality conservation. Also, payments are made based on water quality relative to a control watershed, and therefore, account for stochastic fluctuations in background nitrate levels. Finally, the program pays farmers as a group to elicit team behavior. We present our approach to modeling that allowed us to estimate prices for water and resulting payment levels. We then compare these preliminary estimates to the actual values recorded over 33 months of fieldwork. We find that our actual payments were 29% less than our preliminary estimates, due in part to the failure of our ecological model to estimate discharge accurately. Despite this shortfall, the program attracted the participation of 53% of the farmers in the watershed, and resulted in substantial nitrate abatement activity. Given this favorable response, we propose that research efforts focus on implementing field trials of group-level performance-based payments. Ideally these programs would be low risk and control for naturally occurring contamination. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. Electron-beam lithography with character projection technique for high-throughput exposure with line-edge quality control

    NASA Astrophysics Data System (ADS)

    Ikeno, Rimon; Maruyama, Satoshi; Mita, Yoshio; Ikeda, Makoto; Asada, Kunihiro

    2016-07-01

    The high throughput of character projection (CP) electron-beam (EB) lithography makes it a promising technique for low-to-medium volume device fabrication with regularly arranged layouts, such as for standard-cell logics and memory arrays. However, non-VLSI applications such as MEMS and MOEMS may not be able to fully utilize the benefits of the CP method due to the wide variety of layout figures including curved and oblique edges. In addition, the stepwise shapes that appear because of the EB exposure process often result in intolerable edge roughness, which degrades device performances. In this study, we propose a general EB lithography methodology for such applications utilizing a combination of the CP and variable-shaped beam methods. In the process of layout data conversion with CP character instantiation, several control parameters were optimized to minimize the shot count, improve the edge quality, and enhance the overall device performance. We have demonstrated EB shot reduction and edge-quality improvement with our methodology by using a leading-edge EB exposure tool, ADVANTEST F7000S-VD02, and a high-resolution hydrogen silsesquioxane resist. Atomic force microscope observations were used to analyze the resist edge profiles' quality to determine the influence of the control parameters used in the data conversion process.

  20. Protein Aggregation and Its Impact on Product Quality

    PubMed Central

    Roberts, Christopher J.

    2014-01-01

    Protein pharmaceutical products are typically active as folded monomers that are composed of one or more protein chains, such as the heavy and light chains in monoclonal antibodies that are a mainstay of current drug pipelines. There are numerous possible aggregated states for a given protein, some of which are potentially useful, while most of which are considered deleterious from the perspective of pharmaceutical product quality and performance. This review provides an overview of how and why different aggregated states of proteins occur, how this potentially impacts product quality and performance, fundamental approaches to control aggregate formation, and the practical approaches that are currently used in the pharmaceutical industry. PMID:25173826

Top