Sample records for quality evaluation methods

  1. Dredged Material Evaluations: Review of Zooplankton Toxicity Test Methods for Marine Water Quality Evaluations

    DTIC Science & Technology

    2016-09-01

    Standardization (ISO). 2015. Water quality - calanoid copepod early- life stage test with Acartia tonsa. ISO 16778:2015. International Organization for...Toxicity Test Methods for Marine Water Quality Evaluations by Alan J Kennedy, Guilherme Lotufo, Jennifer G. Laird, and J. Daniel Farrar PURPOSE: The...MPRSA evaluations in some regions. The organisms used in these test methods are not planktonic for most of their life cycles (juveniles and adults

  2. Water Quality Evaluation of the Yellow River Basin Based on Gray Clustering Method

    NASA Astrophysics Data System (ADS)

    Fu, X. Q.; Zou, Z. H.

    2018-03-01

    Evaluating the water quality of 12 monitoring sections in the Yellow River Basin comprehensively by grey clustering method based on the water quality monitoring data from the Ministry of environmental protection of China in May 2016 and the environmental quality standard of surface water. The results can reflect the water quality of the Yellow River Basin objectively. Furthermore, the evaluation results are basically the same when compared with the fuzzy comprehensive evaluation method. The results also show that the overall water quality of the Yellow River Basin is good and coincident with the actual situation of the Yellow River basin. Overall, gray clustering method for water quality evaluation is reasonable and feasible and it is also convenient to calculate.

  3. Quality Evaluation of Raw Moutan Cortex Using the AHP and Gray Correlation-TOPSIS Method

    PubMed Central

    Zhou, Sujuan; Liu, Bo; Meng, Jiang

    2017-01-01

    Background: Raw Moutan cortex (RMC) is an important Chinese herbal medicine. Comprehensive and objective quality evaluation of Chinese herbal medicine has been one of the most important issues in the modern herbs development. Objective: To evaluate and compare the quality of RMC using the weighted gray correlation- Technique for Order Preference by Similarity to an Ideal Solution (TOPSIS) method. Materials and Methods: The percentage composition of gallic acid, catechin, oxypaeoniflorin, paeoniflorin, quercetin, benzoylpaeoniflorin, paeonol in different batches of RMC was determined, and then adopting MATLAB programming to construct the gray correlation-TOPSIS assessment model for quality evaluation of RMC. Results: The quality evaluation results of model evaluation and objective evaluation were consistent, reliable, and stable. Conclusion: The model of gray correlation-TOPSIS can be well applied to the quality evaluation of traditional Chinese medicine with multiple components and has broad prospect in application. SUMMARY The experiment tries to construct a model to evaluate the quality of RMC using the weighted gray correlation- Technique for Order Preference by Similarity to an Ideal Solution (TOPSIS) method. Results show the model is reliable and provide a feasible way in evaluating quality of traditional Chinese medicine with multiple components. PMID:28839384

  4. A method of rapidly evaluating image quality of NED optical system

    NASA Astrophysics Data System (ADS)

    Sun, Qi; Qiu, Chuankai; Yang, Huan

    2014-11-01

    In recent years, with the development of technology of micro-display, advanced optics and the software and hardware, near-to-eye display ( NED) optical system will have a wide range of potential applications in the fields of amusement and virtual reality. However, research on the evaluating image quality of this kind optical system is comparatively lagging behind. Although now there are some methods and equipment for evaluation, they can't be applied in commercial production because of their complex operation and inaccuracy. In this paper, an academic method is proposed and a Rapid Evaluation System (RES) is designed to evaluate the image of optical system rapidly and exactly. Firstly, a set of parameters that eyes are sensitive to and also express the quality of system should be extracted and quantized to be criterion, so the evaluation standards can be established. Then, some parameters can be detected by RES consisted of micro-display, CCD camera and computer and so on. By process of scaling, the measuring results of the RES are exact and creditable, relationship between object measurement, subjective evaluation and the RES will be established. After that, image quality of optical system can be evaluated just by detecting parameters of that. The RES is simple and the results of evaluation are exact and keeping with human vision. So the method can be used not only for optimizing design of optical system, but also for evaluation in commercial production.

  5. An objective method for a video quality evaluation in a 3DTV service

    NASA Astrophysics Data System (ADS)

    Wilczewski, Grzegorz

    2015-09-01

    The following article describes proposed objective method for a 3DTV video quality evaluation, a Compressed Average Image Intensity (CAII) method. Identification of the 3DTV service's content chain nodes enables to design a versatile, objective video quality metric. It is based on an advanced approach to the stereoscopic videostream analysis. Insights towards designed metric mechanisms, as well as the evaluation of performance of the designed video quality metric, in the face of the simulated environmental conditions are herein discussed. As a result, created CAII metric might be effectively used in a variety of service quality assessment applications.

  6. Evaluating the Good Ontology Design Guideline (GoodOD) with the Ontology Quality Requirements and Evaluation Method and Metrics (OQuaRE)

    PubMed Central

    Duque-Ramos, Astrid; Boeker, Martin; Jansen, Ludger; Schulz, Stefan; Iniesta, Miguela; Fernández-Breis, Jesualdo Tomás

    2014-01-01

    Objective To (1) evaluate the GoodOD guideline for ontology development by applying the OQuaRE evaluation method and metrics to the ontology artefacts that were produced by students in a randomized controlled trial, and (2) informally compare the OQuaRE evaluation method with gold standard and competency questions based evaluation methods, respectively. Background In the last decades many methods for ontology construction and ontology evaluation have been proposed. However, none of them has become a standard and there is no empirical evidence of comparative evaluation of such methods. This paper brings together GoodOD and OQuaRE. GoodOD is a guideline for developing robust ontologies. It was previously evaluated in a randomized controlled trial employing metrics based on gold standard ontologies and competency questions as outcome parameters. OQuaRE is a method for ontology quality evaluation which adapts the SQuaRE standard for software product quality to ontologies and has been successfully used for evaluating the quality of ontologies. Methods In this paper, we evaluate the effect of training in ontology construction based on the GoodOD guideline within the OQuaRE quality evaluation framework and compare the results with those obtained for the previous studies based on the same data. Results Our results show a significant effect of the GoodOD training over developed ontologies by topics: (a) a highly significant effect was detected in three topics from the analysis of the ontologies of untrained and trained students; (b) both positive and negative training effects with respect to the gold standard were found for five topics. Conclusion The GoodOD guideline had a significant effect over the quality of the ontologies developed. Our results show that GoodOD ontologies can be effectively evaluated using OQuaRE and that OQuaRE is able to provide additional useful information about the quality of the GoodOD ontologies. PMID:25148262

  7. A Novel Unsupervised Segmentation Quality Evaluation Method for Remote Sensing Images

    PubMed Central

    Tang, Yunwei; Jing, Linhai; Ding, Haifeng

    2017-01-01

    The segmentation of a high spatial resolution remote sensing image is a critical step in geographic object-based image analysis (GEOBIA). Evaluating the performance of segmentation without ground truth data, i.e., unsupervised evaluation, is important for the comparison of segmentation algorithms and the automatic selection of optimal parameters. This unsupervised strategy currently faces several challenges in practice, such as difficulties in designing effective indicators and limitations of the spectral values in the feature representation. This study proposes a novel unsupervised evaluation method to quantitatively measure the quality of segmentation results to overcome these problems. In this method, multiple spectral and spatial features of images are first extracted simultaneously and then integrated into a feature set to improve the quality of the feature representation of ground objects. The indicators designed for spatial stratified heterogeneity and spatial autocorrelation are included to estimate the properties of the segments in this integrated feature set. These two indicators are then combined into a global assessment metric as the final quality score. The trade-offs of the combined indicators are accounted for using a strategy based on the Mahalanobis distance, which can be exhibited geometrically. The method is tested on two segmentation algorithms and three testing images. The proposed method is compared with two existing unsupervised methods and a supervised method to confirm its capabilities. Through comparison and visual analysis, the results verified the effectiveness of the proposed method and demonstrated the reliability and improvements of this method with respect to other methods. PMID:29064416

  8. Evaluating the Good Ontology Design Guideline (GoodOD) with the ontology quality requirements and evaluation method and metrics (OQuaRE).

    PubMed

    Duque-Ramos, Astrid; Boeker, Martin; Jansen, Ludger; Schulz, Stefan; Iniesta, Miguela; Fernández-Breis, Jesualdo Tomás

    2014-01-01

    To (1) evaluate the GoodOD guideline for ontology development by applying the OQuaRE evaluation method and metrics to the ontology artefacts that were produced by students in a randomized controlled trial, and (2) informally compare the OQuaRE evaluation method with gold standard and competency questions based evaluation methods, respectively. In the last decades many methods for ontology construction and ontology evaluation have been proposed. However, none of them has become a standard and there is no empirical evidence of comparative evaluation of such methods. This paper brings together GoodOD and OQuaRE. GoodOD is a guideline for developing robust ontologies. It was previously evaluated in a randomized controlled trial employing metrics based on gold standard ontologies and competency questions as outcome parameters. OQuaRE is a method for ontology quality evaluation which adapts the SQuaRE standard for software product quality to ontologies and has been successfully used for evaluating the quality of ontologies. In this paper, we evaluate the effect of training in ontology construction based on the GoodOD guideline within the OQuaRE quality evaluation framework and compare the results with those obtained for the previous studies based on the same data. Our results show a significant effect of the GoodOD training over developed ontologies by topics: (a) a highly significant effect was detected in three topics from the analysis of the ontologies of untrained and trained students; (b) both positive and negative training effects with respect to the gold standard were found for five topics. The GoodOD guideline had a significant effect over the quality of the ontologies developed. Our results show that GoodOD ontologies can be effectively evaluated using OQuaRE and that OQuaRE is able to provide additional useful information about the quality of the GoodOD ontologies.

  9. A new evaluation method research for fusion quality of infrared and visible images

    NASA Astrophysics Data System (ADS)

    Ge, Xingguo; Ji, Yiguo; Tao, Zhongxiang; Tian, Chunyan; Ning, Chengda

    2017-03-01

    In order to objectively evaluate the fusion effect of infrared and visible image, a fusion evaluation method for infrared and visible images based on energy-weighted average structure similarity and edge information retention value is proposed for drawbacks of existing evaluation methods. The evaluation index of this method is given, and the infrared and visible image fusion results under different algorithms and environments are made evaluation experiments on the basis of this index. The experimental results show that the objective evaluation index is consistent with the subjective evaluation results obtained from this method, which shows that the method is a practical and effective fusion image quality evaluation method.

  10. The Aristotle method: a new concept to evaluate quality of care based on complexity.

    PubMed

    Lacour-Gayet, François; Clarke, David R

    2005-06-01

    Evaluation of quality of care is a duty of the modern medical practice. A reliable method of quality evaluation able to compare fairly institutions and inform a patient and his family of the potential risk of a procedure is clearly needed. It is now well recognized that any method that purports to evaluate quality of care should include a case mix/risk stratification method. No valuable method was available until recently in pediatric cardiac surgery. The Aristotle method is a new concept of evaluation of quality of care in congenital heart surgery based on the complexity of the surgical procedures. Involving a panel of expert surgeons, the project started in 1999 and included 50 pediatric surgeons from 23 countries. The basic score adjusts the complexity of a given procedure and is calculated as the sum of potential for mortality, potential for morbidity and anticipated technical difficulty. The Comprehensive Score further adjusts the complexity according to the specific patient characteristics (anatomy, associated procedures, co-morbidity, etc.). The Aristotle method is original as it introduces several new concepts: the calculated complexity is a constant for a given patient all over the world; complexity is an independent value and risk is a variable depending on the performance; and Performance = Complexity x Outcome. The Aristotle score is a good vector of communication between patients, doctors and insurance companies and may stimulate the quality and the organization of heath care in our field and in others.

  11. A new method to evaluate image quality of CBCT images quantitatively without observers

    PubMed Central

    Shimizu, Mayumi; Okamura, Kazutoshi; Yoshida, Shoko; Weerawanich, Warangkana; Tokumori, Kenji; Jasa, Gainer R; Yoshiura, Kazunori

    2017-01-01

    Objectives: To develop an observer-free method for quantitatively evaluating the image quality of CBCT images by applying just-noticeable difference (JND). Methods: We used two test objects: (1) a Teflon (polytetrafluoroethylene) plate phantom attached to a dry human mandible; and (2) a block phantom consisting of a Teflon step phantom and an aluminium step phantom. These phantoms had holes with different depths. They were immersed in water and scanned with a CB MercuRay (Hitachi Medical Corporation, Tokyo, Japan) at tube voltages of 120 kV, 100 kV, 80 kV and 60 kV. Superimposed images of the phantoms with holes were used for evaluation. The number of detectable holes was used as an index of image quality. In detecting holes quantitatively, the threshold grey value (ΔG), which differentiated holes from the background, was calculated using a specific threshold (the JND), and we extracted the holes with grey values above ΔG. The indices obtained by this quantitative method (the extracted hole values) were compared with the observer evaluations (the observed hole values). In addition, the contrast-to-noise ratio (CNR) of the shallowest detectable holes and the deepest undetectable holes were measured to evaluate the contribution of CNR to detectability. Results: The results of this evaluation method corresponded almost exactly with the evaluations made by observers. The extracted hole values reflected the influence of different tube voltages. All extracted holes had an area with a CNR of ≥1.5. Conclusions: This quantitative method of evaluating CBCT image quality may be more useful and less time-consuming than evaluation by observation. PMID:28045343

  12. Nondestructive methods of evaluating quality of wood in preservative-treated piles

    Treesearch

    Xiping Wang; Robert J. Ross; John R. Erickson; John W. Forsman; Gary D. McGinnis; Rodney C. De Groot

    2000-01-01

    Stress-wave-based nondestructive evaluation methods were used to evaluate the potential quality and modulus of elasticity (MOE) of wood in used preservative-treated Douglas-fir and southern pine piles. Stress wave measurements were conducted on each pile section. Stress wave propagation speeds in the piles were then obtained to estimate their MOE. This was followed by...

  13. Application of Nemerow Index Method and Integrated Water Quality Index Method in Water Quality Assessment of Zhangze Reservoir

    NASA Astrophysics Data System (ADS)

    Zhang, Qian; Feng, Minquan; Hao, Xiaoyan

    2018-03-01

    [Objective] Based on the water quality historical data from the Zhangze Reservoir from the last five years, the water quality was assessed by the integrated water quality identification index method and the Nemerow pollution index method. The results of different evaluation methods were analyzed and compared and the characteristics of each method were identified.[Methods] The suitability of the water quality assessment methods were compared and analyzed, based on these results.[Results] the water quality tended to decrease over time with 2016 being the year with the worst water quality. The sections with the worst water quality were the southern and northern sections.[Conclusion] The results produced by the traditional Nemerow index method fluctuated greatly in each section of water quality monitoring and therefore could not effectively reveal the trend of water quality at each section. The combination of qualitative and quantitative measures of the comprehensive pollution index identification method meant it could evaluate the degree of water pollution as well as determine that the river water was black and odorous. However, the evaluation results showed that the water pollution was relatively low.The results from the improved Nemerow index evaluation were better as the single indicators and evaluation results are in strong agreement; therefore the method is able to objectively reflect the water quality of each water quality monitoring section and is more suitable for the water quality evaluation of the reservoir.

  14. Review of Comprehensive Evaluation Methods for Power Quality and Its Trend in New Generation Energy System

    NASA Astrophysics Data System (ADS)

    Liu, Ruihua; Wang, Rong; Liu, Qunying; Yang, Li; Xi, Chuan; Wang, Wei; Li, Lingzhou; Zhao, Zhoufang; Zhou, Ying

    2018-02-01

    With China’s new energy generation grid connected capacity being in the forefront of the world and the uncertainty of new energy sources, such as wind energy and solar energy, it is be of great significance to study scientific and comprehensive assessment of power quality. On the foundation of analysizing the current power quality index systematically and objectively, the new energy grid power quality analysis method and comprehensive evaluation method, this paper tentatively explored the trend of the new generation of energy system power quality comprehensive evaluation.

  15. Evaluation of air quality zone classification methods based on ambient air concentration exposure.

    PubMed

    Freeman, Brian; McBean, Ed; Gharabaghi, Bahram; Thé, Jesse

    2017-05-01

    Air quality zones are used by regulatory authorities to implement ambient air standards in order to protect human health. Air quality measurements at discrete air monitoring stations are critical tools to determine whether an air quality zone complies with local air quality standards or is noncompliant. This study presents a novel approach for evaluation of air quality zone classification methods by breaking the concentration distribution of a pollutant measured at an air monitoring station into compliance and exceedance probability density functions (PDFs) and then using Monte Carlo analysis with the Central Limit Theorem to estimate long-term exposure. The purpose of this paper is to compare the risk associated with selecting one ambient air classification approach over another by testing the possible exposure an individual living within a zone may face. The chronic daily intake (CDI) is utilized to compare different pollutant exposures over the classification duration of 3 years between two classification methods. Historical data collected from air monitoring stations in Kuwait are used to build representative models of 1-hr NO 2 and 8-hr O 3 within a zone that meets the compliance requirements of each method. The first method, the "3 Strike" method, is a conservative approach based on a winner-take-all approach common with most compliance classification methods, while the second, the 99% Rule method, allows for more robust analyses and incorporates long-term trends. A Monte Carlo analysis is used to model the CDI for each pollutant and each method with the zone at a single station and with multiple stations. The model assumes that the zone is already in compliance with air quality standards over the 3 years under the different classification methodologies. The model shows that while the CDI of the two methods differs by 2.7% over the exposure period for the single station case, the large number of samples taken over the duration period impacts the sensitivity

  16. The study of surgical image quality evaluation system by subjective quality factor method

    NASA Astrophysics Data System (ADS)

    Zhang, Jian J.; Xuan, Jason R.; Yang, Xirong; Yu, Honggang; Koullick, Edouard

    2016-03-01

    GreenLightTM procedure is an effective and economical way of treatment of benign prostate hyperplasia (BPH); there are almost a million of patients treated with GreenLightTM worldwide. During the surgical procedure, the surgeon or physician will rely on the monitoring video system to survey and confirm the surgical progress. There are a few obstructions that could greatly affect the image quality of the monitoring video, like laser glare by the tissue and body fluid, air bubbles and debris generated by tissue evaporation, and bleeding, just to name a few. In order to improve the physician's visual experience of a laser surgical procedure, the system performance parameter related to image quality needs to be well defined. However, since image quality is the integrated set of perceptions of the overall degree of excellence of an image, or in other words, image quality is the perceptually weighted combination of significant attributes (contrast, graininess …) of an image when considered in its marketplace or application, there is no standard definition on overall image or video quality especially for the no-reference case (without a standard chart as reference). In this study, Subjective Quality Factor (SQF) and acutance are used for no-reference image quality evaluation. Basic image quality parameters, like sharpness, color accuracy, size of obstruction and transmission of obstruction, are used as subparameter to define the rating scale for image quality evaluation or comparison. Sample image groups were evaluated by human observers according to the rating scale. Surveys of physician groups were also conducted with lab generated sample videos. The study shows that human subjective perception is a trustworthy way of image quality evaluation. More systematic investigation on the relationship between video quality and image quality of each frame will be conducted as a future study.

  17. Assuring Quality in Education Evaluation.

    ERIC Educational Resources Information Center

    Trochim, William M. K.; Visco, Ronald J.

    1986-01-01

    A number of quality assurance educational evaluation methods are illustrated. Evaluation data obtained from the Providence, Rhode Island, school district are used. The methods are: (1) from auditing, internal control; (2) from accounting, double bookkeeping; and (3) from industrial quality control, acceptance sampling and cumulative percentage…

  18. Image quality evaluation of full reference algorithm

    NASA Astrophysics Data System (ADS)

    He, Nannan; Xie, Kai; Li, Tong; Ye, Yushan

    2018-03-01

    Image quality evaluation is a classic research topic, the goal is to design the algorithm, given the subjective feelings consistent with the evaluation value. This paper mainly introduces several typical reference methods of Mean Squared Error(MSE), Peak Signal to Noise Rate(PSNR), Structural Similarity Image Metric(SSIM) and feature similarity(FSIM) of objective evaluation methods. The different evaluation methods are tested by Matlab, and the advantages and disadvantages of these methods are obtained by analyzing and comparing them.MSE and PSNR are simple, but they are not considered to introduce HVS characteristics into image quality evaluation. The evaluation result is not ideal. SSIM has a good correlation and simple calculation ,because it is considered to the human visual effect into image quality evaluation,However the SSIM method is based on a hypothesis,The evaluation result is limited. The FSIM method can be used for test of gray image and color image test, and the result is better. Experimental results show that the new image quality evaluation algorithm based on FSIM is more accurate.

  19. A Systematic Review of Methods for Evaluating Rating Quality in Language Assessment

    ERIC Educational Resources Information Center

    Wind, Stefanie A.; Peterson, Meghan E.

    2018-01-01

    The use of assessments that require rater judgment (i.e., rater-mediated assessments) has become increasingly popular in high-stakes language assessments worldwide. Using a systematic literature review, the purpose of this study is to identify and explore the dominant methods for evaluating rating quality within the context of research on…

  20. [Comparison of 4 methods of evaluating protein quality in vegetable sources].

    PubMed

    Muñoz de Maquiña, A; Gross, R; Schoeneberger, H; Villacorta, L

    1983-12-01

    This study compares the practical value of the following methods: protein efficiency ratio (PER), blood urea concentration in rats (BUC), relative nutritive value (RNV), and predicted protein value (PPV) to evaluate the protein quality of 41 diets of plant origin. Results demonstrated low correlations between PER and RNV (r = 0.66), PER and PPV (r = 0.53), RNV and PPV (r = 0.54), whereas there was a high negative correlation between PER and BUC (r = -0.89). These different procedures can be useful and valid for distinct and well-defined objectives, but the evaluation of results must be made in accordance with the purpose of the experiment. In assessing the protein quality of foodstuffs, it is therefore recommended that mathematical computer models be developed which take into account the cybernetic system of the amino acid metabolism. This would definitely reduce the actual need of expensive long-term biological assays.

  1. Image Quality Assessment of High-Resolution Satellite Images with Mtf-Based Fuzzy Comprehensive Evaluation Method

    NASA Astrophysics Data System (ADS)

    Wu, Z.; Luo, Z.; Zhang, Y.; Guo, F.; He, L.

    2018-04-01

    A Modulation Transfer Function (MTF)-based fuzzy comprehensive evaluation method was proposed in this paper for the purpose of evaluating high-resolution satellite image quality. To establish the factor set, two MTF features and seven radiant features were extracted from the knife-edge region of image patch, which included Nyquist, MTF0.5, entropy, peak signal to noise ratio (PSNR), average difference, edge intensity, average gradient, contrast and ground spatial distance (GSD). After analyzing the statistical distribution of above features, a fuzzy evaluation threshold table and fuzzy evaluation membership functions was established. The experiments for comprehensive quality assessment of different natural and artificial objects was done with GF2 image patches. The results showed that the calibration field image has the highest quality scores. The water image has closest image quality to the calibration field, quality of building image is a little poor than water image, but much higher than farmland image. In order to test the influence of different features on quality evaluation, the experiment with different weights were tested on GF2 and SPOT7 images. The results showed that different weights correspond different evaluating effectiveness. In the case of setting up the weights of edge features and GSD, the image quality of GF2 is better than SPOT7. However, when setting MTF and PSNR as main factor, the image quality of SPOT7 is better than GF2.

  2. [Discussion on Quality Evaluation Method of Medical Device During Life-Cycle in Operation Based on the Analytic Hierarchy Process].

    PubMed

    Zheng, Caixian; Zheng, Kun; Shen, Yunming; Wu, Yunyun

    2016-01-01

    The content related to the quality during life-cycle in operation of medical device includes daily use, repair volume, preventive maintenance, quality control and adverse event monitoring. In view of this, the article aims at discussion on the quality evaluation method of medical devices during their life cycle in operation based on the Analytic Hierarchy Process (AHP). The presented method is proved to be effective by evaluating patient monitors as example. The method presented in can promote and guide the device quality control work, and it can provide valuable inputs to decisions about purchase of new device.

  3. The method of quality marker research and quality evaluation of traditional Chinese medicine based on drug properties and effect characteristics.

    PubMed

    Zhang, Tiejun; Bai, Gang; Han, Yanqi; Xu, Jun; Gong, Suxiao; Li, Yazhuo; Zhang, Hongbing; Liu, Changxiao

    2018-05-15

    Quality of traditional Chinese medicine (TCM) plays a critical role in industry of TCM. Rapid development of TCM pharmaceutical areas is, however, greatly limited, since there are many issues not been resolved, concerning the quality study of TCM. Core concept of TCM quality as well as the characteristics of TCM was discussed, in order to guide the quality research and evaluation of TCM, further improve the level of TCM quality control. In this review, on the basis of systematic analysis of fundamental property and features of TCM in clinical application, the approaches and methods of quality marker (Q-marker) study were proposed through combination of transitivity and traceability of essentials of quality, correlation between chemical ingredients and drug property/efficacy, as well as analysis of endemicity of ingredients sharing similar pharmacophylogenetic and biosynthetic approaches. The approaches and methods of Q-marker study were proposed and the novel integrated pattern for quality assessment and control of TCM was established. The core concept of Q-marker has helped to break through the bottleneck of the current fragmented quality research of TCM and improved the scientificity, integrity and systematicness of quality control. Copyright © 2018 Elsevier GmbH. All rights reserved.

  4. Evaluating quality of patient care communication in integrated care settings: a mixed method approach.

    PubMed

    Gulmans, J; Vollenbroek-Hutten, M M R; Van Gemert-Pijnen, J E W C; Van Harten, W H

    2007-10-01

    Owing to the involvement of multiple professionals from various institutions, integrated care settings are prone to suboptimal patient care communication. To assure continuity, communication gaps should be identified for targeted improvement initiatives. However, available assessment methods are often one-sided evaluations not appropriate for integrated care settings. We developed an evaluation approach that takes into account the multiple communication links and evaluation perspectives inherent to these settings. In this study, we describe this approach, using the integrated care setting of Cerebral Palsy as illustration. The approach follows a three-step mixed design in which the results of each step are used to mark out the subsequent step's focus. The first step patient questionnaire aims to identify quality gaps experienced by patients, comparing their expectancies and experiences with respect to patient-professional and inter-professional communication. Resulting gaps form the input of in-depth interviews with a subset of patients to evaluate underlying factors of ineffective communication. Resulting factors form the input of the final step's focus group meetings with professionals to corroborate and complete the findings. By combining methods, the presented approach aims to minimize limitations inherent to the application of single methods. The comprehensiveness of the approach enables its applicability in various integrated care settings. Its sequential design allows for in-depth evaluation of relevant quality gaps. Further research is needed to evaluate the approach's feasibility in practice. In our subsequent study, we present the results of the approach in the integrated care setting of children with Cerebral Palsy in three Dutch care regions.

  5. Evaluating Service Quality from Patients' Perceptions: Application of Importance-performance Analysis Method.

    PubMed

    Mohebifar, Rafat; Hasani, Hana; Barikani, Ameneh; Rafiei, Sima

    2016-08-01

    Providing high service quality is one of the main functions of health systems. Measuring service quality is the basic prerequisite for improving quality. The aim of this study was to evaluate the quality of service in teaching hospitals using importance-performance analysis matrix. A descriptive-analytic study was conducted through a cross-sectional method in six academic hospitals of Qazvin, Iran, in 2012. A total of 360 patients contributed to the study. The sampling technique was stratified random sampling. Required data were collected based on a standard questionnaire (SERVQUAL). Data analysis was done through SPSS version 18 statistical software and importance-performance analysis matrix. The results showed a significant gap between importance and performance in all five dimensions of service quality (p < 0.05). In reviewing the gap, "reliability" (2.36) and "assurance" (2.24) dimensions had the highest quality gap and "responsiveness" had the lowest gap (1.97). Also, according to findings, reliability and assurance were in Quadrant (I), empathy was in Quadrant (II), and tangibles and responsiveness were in Quadrant (IV) of the importance-performance matrix. The negative gap in all dimensions of quality shows that quality improvement is necessary in all dimensions. Using quality and diagnosis measurement instruments such as importance-performance analysis will help hospital managers with planning of service quality improvement and achieving long-term goals.

  6. Method for evaluation of human induced pluripotent stem cell quality using image analysis based on the biological morphology of cells.

    PubMed

    Wakui, Takashi; Matsumoto, Tsuyoshi; Matsubara, Kenta; Kawasaki, Tomoyuki; Yamaguchi, Hiroshi; Akutsu, Hidenori

    2017-10-01

    We propose an image analysis method for quality evaluation of human pluripotent stem cells based on biologically interpretable features. It is important to maintain the undifferentiated state of induced pluripotent stem cells (iPSCs) while culturing the cells during propagation. Cell culture experts visually select good quality cells exhibiting the morphological features characteristic of undifferentiated cells. Experts have empirically determined that these features comprise prominent and abundant nucleoli, less intercellular spacing, and fewer differentiating cellular nuclei. We quantified these features based on experts' visual inspection of phase contrast images of iPSCs and found that these features are effective for evaluating iPSC quality. We then developed an iPSC quality evaluation method using an image analysis technique. The method allowed accurate classification, equivalent to visual inspection by experts, of three iPSC cell lines.

  7. A network-based method to evaluate quality of reproducibility of differential expression in cancer genomics studies

    PubMed Central

    Geng, Haijiang; Li, Zhihui; Li, Jiabing; Lu, Tao; Yan, Fangrong

    2015-01-01

    BACKGROUND Personalized cancer treatments depend on the determination of a patient's genetic status according to known genetic profiles for which targeted treatments exist. Such genetic profiles must be scientifically validated before they is applied to general patient population. Reproducibility of findings that support such genetic profiles is a fundamental challenge in validation studies. The percentage of overlapping genes (POG) criterion and derivative methods produce unstable and misleading results. Furthermore, in a complex disease, comparisons between different tumor subtypes can produce high POG scores that do not capture the consistencies in the functions. RESULTS We focused on the quality rather than the quantity of the overlapping genes. We defined the rank value of each gene according to importance or quality by PageRank on basis of a particular topological structure. Then, we used the p-value of the rank-sum of the overlapping genes (PRSOG) to evaluate the quality of reproducibility. Though the POG scores were low in different studies of the same disease, the PRSOG was statistically significant, which suggests that sets of differentially expressed genes might be highly reproducible. CONCLUSIONS Evaluations of eight datasets from breast cancer, lung cancer and four other disorders indicate that quality-based PRSOG method performs better than a quantity-based method. Our analysis of the components of the sets of overlapping genes supports the utility of the PRSOG method. PMID:26556852

  8. An evaluation method of power quality about electrified railways connected to power grid based on PSCAD/EMTDC

    NASA Astrophysics Data System (ADS)

    Liang, Weibin; Ouyang, Sen; Huang, Xiang; Su, Weijian

    2017-05-01

    The existing modeling process of power quality about electrified railways connected to power grid is complicated and the simulation scene is incomplete, so this paper puts forward a novel evaluation method of power quality based on PSCAD/ETMDC. Firstly, a model of power quality about electrified railways connected to power grid is established, which is based on testing report or measured data. The equivalent model of electrified locomotive contains power characteristic and harmonic characteristic, which are substituted by load and harmonic source. Secondly, in order to make evaluation more complete, an analysis scheme has been put forward. The scheme uses a combination of three-dimensions of electrified locomotive, which contains types, working conditions and quantity. At last, Shenmao Railway is taken as example to evaluate the power quality at different scenes, and the result shows electrified railways connected to power grid have significant effect on power quality.

  9. [Evaluating comprehensive quality of sediment in Dianchi Lake using adjusted AHP method and 137Cs dating].

    PubMed

    Zhang, Yan; Deng, Xi-Hai; Peng, Bu-Zhuo

    2006-08-01

    It is difficult to evaluate comprehensive quality of sediment and to understand development trend of pollution because of absence of monitoring data, especially history data. Combining the method of 137Cs dating with the ways of general sampling and measurement can easily resolve the problem of absence of data and also provide the possibility for calculating weighted environmental quality comprehensive index using the adjusted analytical hierarchy process (AHP) method. In order to overcome the willfulness the judgment matrix is formed objectively based on calculating monitoring data. Based on the monitoring data of sediment pollution and the weights of various factors gained by adjusted AHP method the comprehensive quality of sediment in each zone of Dianchi Lake was evaluated and the results indicated that the pollution of sediments in each zone at the present be serious more than that in the history. The condition may be related to the industrial development and distribution of industries in Dianchi Lake basin. Therefore, in order to improve the comprehensive quality of sediment in Dianchi Lake and to prevent the secondary pollution of heavy metals in sediment from happening, it is necessary to control the pollutants discharge and to remove the pollutants with various ways.

  10. Learning Evaluation: blending quality improvement and implementation research methods to study healthcare innovations.

    PubMed

    Balasubramanian, Bijal A; Cohen, Deborah J; Davis, Melinda M; Gunn, Rose; Dickinson, L Miriam; Miller, William L; Crabtree, Benjamin F; Stange, Kurt C

    2015-03-10

    In healthcare change interventions, on-the-ground learning about the implementation process is often lost because of a primary focus on outcome improvements. This paper describes the Learning Evaluation, a methodological approach that blends quality improvement and implementation research methods to study healthcare innovations. Learning Evaluation is an approach to multi-organization assessment. Qualitative and quantitative data are collected to conduct real-time assessment of implementation processes while also assessing changes in context, facilitating quality improvement using run charts and audit and feedback, and generating transportable lessons. Five principles are the foundation of this approach: (1) gather data to describe changes made by healthcare organizations and how changes are implemented; (2) collect process and outcome data relevant to healthcare organizations and to the research team; (3) assess multi-level contextual factors that affect implementation, process, outcome, and transportability; (4) assist healthcare organizations in using data for continuous quality improvement; and (5) operationalize common measurement strategies to generate transportable results. Learning Evaluation principles are applied across organizations by the following: (1) establishing a detailed understanding of the baseline implementation plan; (2) identifying target populations and tracking relevant process measures; (3) collecting and analyzing real-time quantitative and qualitative data on important contextual factors; (4) synthesizing data and emerging findings and sharing with stakeholders on an ongoing basis; and (5) harmonizing and fostering learning from process and outcome data. Application to a multi-site program focused on primary care and behavioral health integration shows the feasibility and utility of Learning Evaluation for generating real-time insights into evolving implementation processes. Learning Evaluation generates systematic and rigorous cross

  11. [Evaluating quality and effectiveness in the promotion of health: approaches and methods of public health and social sciences].

    PubMed

    Deccache, A

    1997-06-01

    Health promotion and health education have often been limited to evaluation of the effectiveness of actions and programmes. However, since 1996 with the Third European Conference on Health Promotion and Education Effectiveness, many researchers have become interested in "quality assessment" and new ways of thinking have emerged. Quality assurance is a concept and activity developed in industry with the objective of increasing production efficiency. There are two distinct approaches: External Standard Inspection (ESI) and Continuous Quality Improvement (CQI). ESI involves establishing criteria of quality, evaluating them and improving whatever needs improvement. CQI views the activity or service as a process and includes the quality assessment as part of the process. This article attempts to answer the questions of whether these methods are sufficient and suitable for operationalising the concepts of evaluation, effectiveness and quality in health promotion and education, whether it is necessary to complement them with other methods, and whether the ESI approach is appropriate. The first section of the article explains that health promotion is based on various paradigms from epidemiology to psychology and anthropology. Many authors warn against the exclusive use of public health disciplines for understanding, implementing and evaluating health promotion. The author argues that in practice, health promotion: -integrates preventive actions with those aiming to maintain and improve health, a characteristic which widens the actions of health promotion from those of classic public health which include essentially an epidemiological or "risk" focus; -aims to replace vertical approaches to prevention with a global approach based on educational sciences; -involves a community approach which includes the individual in a "central position of power" as much in the definition of needs as in the evaluation of services; -includes the participation and socio-political actions

  12. Current status of quality evaluation of nursing care through director review and reflection from the Nursing Quality Control Centers

    PubMed Central

    Duan, Xia; Shi, Yan

    2014-01-01

    Background: The quality evaluation of nursing care is a key link in medical quality management. It is important and worth studying for the nursing supervisors to know the disadvantages during the process of quality evaluation of nursing care and then to improve the whole nursing quality. This study was to provide director insight on the current status of quality evaluation of nursing care from Nursing Quality Control Centers (NQCCs). Material and Methods: This qualitative study used a sample of 12 directors from NQCCs who were recruited from 12 provinces in China to evaluate the current status of quality evaluation of nursing care. Data were collected by in-depth interviews. Content analysis method was used to analyze the data. Results: Four themes emerged from the data: 1) lag of evaluation index; 2) limitations of evaluation content; 3) simplicity of evaluation method; 4) excessive emphasis on terminal quality. Conclusion: It is of great realistic significance to ameliorate nursing quality evaluation criteria, modify the evaluation content based on patient needs-oriented idea, adopt scientific evaluation method to evaluate nursing quality, and scientifically and reasonably draw horizontal comparisons of nursing quality between hospitals, as well as longitudinal comparisons of a hospital’s nursing quality. These methods mentioned above can all enhance a hospital’s core competitiveness and benefit more patients. PMID:25419427

  13. Evaluation of quality improvement programmes

    PubMed Central

    Ovretveit, J; Gustafson, D

    2002-01-01

    

 In response to increasing concerns about quality, many countries are carrying out large scale programmes which include national quality strategies, hospital programmes, and quality accreditation, assessment and review processes. Increasing amounts of resources are being devoted to these interventions, but do they ensure or improve quality of care? There is little research evidence as to their effectiveness or the conditions for maximum effectiveness. Reasons for the lack of evaluation research include the methodological challenges of measuring outcomes and attributing causality to these complex, changing, long term social interventions to organisations or health systems, which themselves are complex and changing. However, methods are available which can be used to evaluate these programmes and which can provide decision makers with research based guidance on how to plan and implement them. This paper describes the research challenges, the methods which can be used, and gives examples and guidance for future research. It emphasises the important contribution which such research can make to improving the effectiveness of these programmes and to developing the science of quality improvement. PMID:12486994

  14. Method and Apparatus for Evaluating the Visual Quality of Processed Digital Video Sequences

    NASA Technical Reports Server (NTRS)

    Watson, Andrew B. (Inventor)

    2002-01-01

    A Digital Video Quality (DVQ) apparatus and method that incorporate a model of human visual sensitivity to predict the visibility of artifacts. The DVQ method and apparatus are used for the evaluation of the visual quality of processed digital video sequences and for adaptively controlling the bit rate of the processed digital video sequences without compromising the visual quality. The DVQ apparatus minimizes the required amount of memory and computation. The input to the DVQ apparatus is a pair of color image sequences: an original (R) non-compressed sequence, and a processed (T) sequence. Both sequences (R) and (T) are sampled, cropped, and subjected to color transformations. The sequences are then subjected to blocking and discrete cosine transformation, and the results are transformed to local contrast. The next step is a time filtering operation which implements the human sensitivity to different time frequencies. The results are converted to threshold units by dividing each discrete cosine transform coefficient by its respective visual threshold. At the next stage the two sequences are subtracted to produce an error sequence. The error sequence is subjected to a contrast masking operation, which also depends upon the reference sequence (R). The masked errors can be pooled in various ways to illustrate the perceptual error over various dimensions, and the pooled error can be converted to a visual quality measure.

  15. Evaluating Quality Management in University Departments

    ERIC Educational Resources Information Center

    Becket, Nina; Brookes, Maureen

    2006-01-01

    Purpose: Despite the abundance of research on quality management there is no universal consensus on how best to measure quality in higher education. This paper undertakes a critical evaluation of the different methods used to assess the quality of provision in higher education departments in the UK. Design/methodology/approach: Drawing on relevant…

  16. A method for evaluating treatment quality using in vivo EPID dosimetry and statistical process control in radiation therapy.

    PubMed

    Fuangrod, Todsaporn; Greer, Peter B; Simpson, John; Zwan, Benjamin J; Middleton, Richard H

    2017-03-13

    Purpose Due to increasing complexity, modern radiotherapy techniques require comprehensive quality assurance (QA) programmes, that to date generally focus on the pre-treatment stage. The purpose of this paper is to provide a method for an individual patient treatment QA evaluation and identification of a "quality gap" for continuous quality improvement. Design/methodology/approach A statistical process control (SPC) was applied to evaluate treatment delivery using in vivo electronic portal imaging device (EPID) dosimetry. A moving range control chart was constructed to monitor the individual patient treatment performance based on a control limit generated from initial data of 90 intensity-modulated radiotherapy (IMRT) and ten volumetric-modulated arc therapy (VMAT) patient deliveries. A process capability index was used to evaluate the continuing treatment quality based on three quality classes: treatment type-specific, treatment linac-specific, and body site-specific. Findings The determined control limits were 62.5 and 70.0 per cent of the χ pass-rate for IMRT and VMAT deliveries, respectively. In total, 14 patients were selected for a pilot study the results of which showed that about 1 per cent of all treatments contained errors relating to unexpected anatomical changes between treatment fractions. Both rectum and pelvis cancer treatments demonstrated process capability indices were less than 1, indicating the potential for quality improvement and hence may benefit from further assessment. Research limitations/implications The study relied on the application of in vivo EPID dosimetry for patients treated at the specific centre. Sampling patients for generating the control limits were limited to 100 patients. Whilst the quantitative results are specific to the clinical techniques and equipment used, the described method is generally applicable to IMRT and VMAT treatment QA. Whilst more work is required to determine the level of clinical significance, the

  17. [Evaluation method with radiographic image quality indicator for internal defects of dental casting metallic restoration].

    PubMed

    Li, Y; Zheng, G; Lin, H

    2014-12-18

    To develop a new kind of dental radiographic image quality indicator (IQI) for internal quality of casting metallic restoration to influence on its usage life. Radiographic image quality indicator method was used to evaluate the depth of the defects region and internal quality of 127 casting metallic restoration and the accuracy was compared with that of conventional callipers method. In the 127 cases of casting metallic restoration, 9 were found the thickness less than 0.7 mm and the thinnest thickness only 0.2 mm in 26 casting metallic crowns or bridges' occlusal defects region. The data measured by image quality indicator were consistent with those measured by conventional gauging. Two metal inner crowns were found the thickness less than 0.3 mm in 56 porcelain crowns or bridges. The thickness of casting removable partial denture was more than 1.0 mm, but thinner regions were not found. It was found that in a titanium partial denture, the X-ray image of clasp was not uniform and there were internal porosity defects in the clasp. Special dental image quality indicator can solve the visual error problems caused by different observing backgrounds and estimate the depth of the defects region in the casting.

  18. Developing and executing quality improvement projects (concept, methods, and evaluation).

    PubMed

    Likosky, Donald S

    2014-03-01

    Continuous quality improvement, quality assurance, cycles of change--these words of often used to express the process of using data to inform and improve clinical care. Although many of us have been exposed to theories and practice of experimental work (e.g., randomized trial), few of us have been similarly exposed to the science underlying quality improvement. Through the lens of a single-center quality improvement study, this article exposes the reader to methodology for conducting such studies. The reader will gain an understanding of these methods required to embark on such a study.

  19. Quality Evaluation of Pork with Various Freezing and Thawing Methods

    PubMed Central

    2014-01-01

    In this study, the physicochemical and sensory quality characteristics due to the influence of various thawing methods on electro-magnetic and air blast frozen pork were examined. The packaged pork samples, which were frozen by air blast freezing at −45℃ or electro-magnetic freezing at −55℃, were thawed using 4 different methods: refrigeration (4±1℃), room temperature (RT, 25℃), cold water (15℃), and microwave (2450 MHz). Analyses were carried out to determine the drip and cooking loss, water holding capacity (WHC), moisture content and sensory evaluation. Frozen pork thawed in a microwave indicated relatively less thawing loss (0.63-1.24%) than the other thawing methods (0.68-1.38%). The cooking loss after electro-magnetic freezing indicated 37.4% by microwave thawing, compared with 32.9% by refrigeration, 36.5% by RT, and 37.2% by cold water in ham. The thawing of samples frozen by electro-magnetic freezing showed no significant differences between the methods used, while the moisture content was higher in belly thawed by microwave (62.0%) after electro-magnetic freezing than refrigeration (54.8%), RT (61.3%), and cold water (61.1%). The highest overall acceptability was shown for microwave thawing after electro-magnetic freezing but there were no significant differences compared to that of the other samples. PMID:26761493

  20. Image Quality Ranking Method for Microscopy

    PubMed Central

    Koho, Sami; Fazeli, Elnaz; Eriksson, John E.; Hänninen, Pekka E.

    2016-01-01

    Automated analysis of microscope images is necessitated by the increased need for high-resolution follow up of events in time. Manually finding the right images to be analyzed, or eliminated from data analysis are common day-to-day problems in microscopy research today, and the constantly growing size of image datasets does not help the matter. We propose a simple method and a software tool for sorting images within a dataset, according to their relative quality. We demonstrate the applicability of our method in finding good quality images in a STED microscope sample preparation optimization image dataset. The results are validated by comparisons to subjective opinion scores, as well as five state-of-the-art blind image quality assessment methods. We also show how our method can be applied to eliminate useless out-of-focus images in a High-Content-Screening experiment. We further evaluate the ability of our image quality ranking method to detect out-of-focus images, by extensive simulations, and by comparing its performance against previously published, well-established microscopy autofocus metrics. PMID:27364703

  1. Capsicum--production, technology, chemistry, and quality. Part IV. Evaluation of quality.

    PubMed

    Govindarajan, V S; Rajalakshmi, D; Chand, N

    1987-01-01

    Capsicum fruits are popular worldwide and are used in the cuisines of both the developing and the developed countries. With its different varieties, forms, and uses, the spice capsicum contributes to the entire gamut of sensory experience--color as finely ground paprika powder or extract in sausages, goulash, cheese, and snacks; both pungency and color as the many varieties of chillies used in Mexican, African, Indian, and southeast Asian cuisines; color, aroma, and mild pungency as the fresh green chillies used in many of the growing countries; and appearance, color, aroma, and texture as fresh fruit in salads and as a pickled and canned product. In three earlier parts in this series, the varieties, cultivation, and primary processing; the processed products, world production, and trade; and the chemistry of the color, aroma, and pungency stimuli have been reviewed. In this part, the evaluation of quality through instrumental determination of the causal components and the sensory evaluation of color, aroma, and pungency are discussed. Several methods for quantitative determination of the stimuli and the sensory evaluation of the responses to the stimuli are reviewed. The problems of sensory evaluation of color, aroma, and pungency, the dominant attributes for validation of the instrumentally determined values for carotenoids, volatiles, or particular fractions, and total and individual capsaicinoids are specifically discussed. Summarized details of selected instrumental methods for evaluating the stimuli, which are either validated by correlation to sensorily perceived responses or to adopted standards, are given along with representative data obtained for discussing the adequacy and reliability of the methods. Pungency as a specific gustatory perception and the many methods proposed to evaluate this quality are discussed. A recommended objective procedure for obtaining reproducible values is discussed, and a method for relating different panel results is shown

  2. Quality control of colonoscopy procedures: a prospective validated method for the evaluation of professional practices applicable to all endoscopic units.

    PubMed

    Coriat, R; Pommaret, E; Chryssostalis, A; Viennot, S; Gaudric, M; Brezault, C; Lamarque, D; Roche, H; Verdier, D; Parlier, D; Prat, F; Chaussade, S

    2009-02-01

    To produce valid information, an evaluation of professional practices has to assess the quality of all practices before, during and after the procedure under study. Several auditing techniques have been proposed for colonoscopy. The purpose of this work is to describe a straightforward original validated method for the prospective evaluation of professional practices in the field of colonoscopy applicable in all endoscopy units without increasing the staff work load. Pertinent quality-control criteria (14 items) were identified by the endoscopists at the Cochin Hospital and were compatible with: findings in the available literature; guidelines proposed by the Superior Health Authority; and application in any endoscopy unit. Prospective routine data were collected and the methodology validated by evaluating 50 colonoscopies every quarter for one year. The relevance of the criteria was assessed using data collected during four separate periods. The standard checklist was complete for 57% of the colonoscopy procedures. The colonoscopy procedure was appropriate according to national guidelines in 94% of cases. These observations were particularly noteworthy: the quality of the colonic preparation was insufficient for 9% of the procedures; complete colonoscopy was achieved for 93% of patients; and 0.38 adenomas and 0.045 carcinomas were identified per colonoscopy. This simple and reproducible method can be used for valid quality-control audits in all endoscopy units. In France, unit-wide application of this method enables endoscopists to validate 100 of the 250 points required for continuous medical training. This is a quality-control tool that can be applied annually, using a random month to evaluate any changes in routine practices.

  3. Exploring in integrated quality evaluation of Chinese herbal medicines: the integrated quality index (IQI) for aconite.

    PubMed

    Zhang, Ding-kun; Wang, Jia-bo; Yang, Ming; Peng, Cheng; Xiao, Xiao-he

    2015-07-01

    Good medicinal herbs, good drugs. Good evaluation method and indices are the prerequisite of good medicinal herbs. However, there exist numerous indices for quality evaluation and control in Chinese medicinal materials. However, most of these indices are non-interrelated each other, as well as having little relationship with efficiency and safety. The results of different evaluatior methods may not be consistent, even contradictory. Considering the complex material properties of Chinese medicinal materials, single method and index is difficult to objectively and comprehensively reflect the quality. Therefore, it is essential to explore the integrated evaluation methods. In this paper, oriented by the integrated evaluation strategies for traditional Chinese medicine quality, a new method called integrated quality index (IQI) by the integration of empirical evaluation, chemical evaluation, and biological evaluation was proposed. In addition, a study case of hypertoxic herb Aconitum carmichaelii Debx. was provided to explain this method in detail. The results suggested that in the view of specifications, the average weight of Jiangyou aconite was the greatest, followed by Weishan aconite, Butuo aconite, Hanzhong aconite, and Anxian aconite; from the point of chemical components, Jiangyou aconite had the characteristic with strong efficacy and weak toxicity, next was Hanzhong aconite, Butuo aconite, Weishan aconite, and Anxian aconite; taking toxicity price as the index, Hanzhong aconite and Jiangyou aconite have the lower toxicity, while Butuo aconite, Weishan aconite, and Anxian aconite have the relatively higher one. After the normalization and integration of evaluation results, we calculated the IQI value of Jiangyou aconite, Hanzhong aconite, Butuo aconite, Weishan aconite, and Anxian aconite were 0.842 +/- 0.091, 0.597 +/- 0.047, 0.442 +/- 0.033, 0.454 +/- 0.038, 0.170 +/- 0.021, respectively. The quality of Jiangyou aconite is significantly better than the

  4. [Research progress on identification and quality evaluation of glues medicines].

    PubMed

    Li, Hui-Hu; Ren, Gang; Chen, Li-Min; Zhong, Guo-Yue

    2018-01-01

    Glues medicines is a special kind of traditional Chinese medicine.As the market demand is large, the raw materials are in short supply and lacks proper quality evaluation technology, which causes inconsistent quality of products on the market. Its authentic identification and evaluation stay a problem to be solved. In this paper, the research progress of the methods and techniques of the evaluation of the identification and quality of glues medicines were reviewed. The researches of medicinal glue type identification and quality evaluation mainly concentrated in four aspects of medicinal materials of physical and chemical properties, trace elements, organic chemicals and biological genetic methods and techniques. The methods of physicochemical properties include thermal analysis, gel electrophoresis, isoelectric focusing electrophoresis, infrared spectroscopy, gel exclusion chromatography, and circular dichroism. The methods including atomic absorption spectrometry, X-ray fluorescence spectrometry, plasma emission spectrometry and visible spectrophotometry were used for the study of the trace elements of glues medicines. The organic chemical composition was studied by methods of composition of amino acids, content detection, odor detection, lipid soluble component, organic acid detection. Methods based on the characteristics of biogenetics include DNA, polypeptide and amino acid sequence difference analysis. Overall, because of relative components similarity of the glues medicines (such as amino acids, proteins and peptides), its authenticity and quality evaluation index is difficult to judge objectively, all sorts of identification evaluation methods have different characteristics, but also their limitations. It indicates that further study should focus on identification of evaluation index and various technology integrated application combining with the characteristics of the production process. Copyright© by the Chinese Pharmaceutical Association.

  5. New Methods for Air Quality Model Evaluation with Satellite Data

    NASA Astrophysics Data System (ADS)

    Holloway, T.; Harkey, M.

    2015-12-01

    Despite major advances in the ability of satellites to detect gases and aerosols in the atmosphere, there remains significant, untapped potential to apply space-based data to air quality regulatory applications. Here, we showcase research findings geared toward increasing the relevance of satellite data to support operational air quality management, focused on model evaluation. Particular emphasis is given to nitrogen dioxide (NO2) and formaldehyde (HCHO) from the Ozone Monitoring Instrument aboard the NASA Aura satellite, and evaluation of simulations from the EPA Community Multiscale Air Quality (CMAQ) model. This work is part of the NASA Air Quality Applied Sciences Team (AQAST), and is motivated by ongoing dialog with state and federal air quality management agencies. We present the response of satellite-derived NO2 to meteorological conditions, satellite-derived HCHO:NO2 ratios as an indicator of ozone production regime, and the ability of models to capture these sensitivities over the continental U.S. In the case of NO2-weather sensitivities, we find boundary layer height, wind speed, temperature, and relative humidity to be the most important variables in determining near-surface NO2 variability. CMAQ agreed with relationships observed in satellite data, as well as in ground-based data, over most regions. However, we find that the southwest U.S. is a problem area for CMAQ, where modeled NO2 responses to insolation, boundary layer height, and other variables are at odds with the observations. Our analyses utilize a software developed by our team, the Wisconsin Horizontal Interpolation Program for Satellites (WHIPS): a free, open-source program designed to make satellite-derived air quality data more usable. WHIPS interpolates level 2 satellite retrievals onto a user-defined fixed grid, in effect creating custom-gridded level 3 satellite product. Currently, WHIPS can process the following data products: OMI NO2 (NASA retrieval); OMI NO2 (KNMI retrieval); OMI

  6. Subjective evaluation of compressed image quality

    NASA Astrophysics Data System (ADS)

    Lee, Heesub; Rowberg, Alan H.; Frank, Mark S.; Choi, Hyung-Sik; Kim, Yongmin

    1992-05-01

    Lossy data compression generates distortion or error on the reconstructed image and the distortion becomes visible as the compression ratio increases. Even at the same compression ratio, the distortion appears differently depending on the compression method used. Because of the nonlinearity of the human visual system and lossy data compression methods, we have evaluated subjectively the quality of medical images compressed with two different methods, an intraframe and interframe coding algorithms. The evaluated raw data were analyzed statistically to measure interrater reliability and reliability of an individual reader. Also, the analysis of variance was used to identify which compression method is better statistically, and from what compression ratio the quality of a compressed image is evaluated as poorer than that of the original. Nine x-ray CT head images from three patients were used as test cases. Six radiologists participated in reading the 99 images (some were duplicates) compressed at four different compression ratios, original, 5:1, 10:1, and 15:1. The six readers agree more than by chance alone and their agreement was statistically significant, but there were large variations among readers as well as within a reader. The displacement estimated interframe coding algorithm is significantly better in quality than that of the 2-D block DCT at significance level 0.05. Also, 10:1 compressed images with the interframe coding algorithm do not show any significant differences from the original at level 0.05.

  7. Experienced quality factors: qualitative evaluation approach to audiovisual quality

    NASA Astrophysics Data System (ADS)

    Jumisko-Pyykkö, Satu; Häkkinen, Jukka; Nyman, Göte

    2007-02-01

    Subjective evaluation is used to identify impairment factors of multimedia quality. The final quality is often formulated via quantitative experiments, but this approach has its constraints, as subject's quality interpretations, experiences and quality evaluation criteria are disregarded. To identify these quality evaluation factors, this study examined qualitatively the criteria participants used to evaluate audiovisual video quality. A semi-structured interview was conducted with 60 participants after a subjective audiovisual quality evaluation experiment. The assessment compared several, relatively low audio-video bitrate ratios with five different television contents on mobile device. In the analysis, methodological triangulation (grounded theory, Bayesian networks and correspondence analysis) was applied to approach the qualitative quality. The results showed that the most important evaluation criteria were the factors of visual quality, contents, factors of audio quality, usefulness - followability and audiovisual interaction. Several relations between the quality factors and the similarities between the contents were identified. As a research methodological recommendation, the focus on content and usage related factors need to be further examined to improve the quality evaluation experiments.

  8. Evaluation Methods of The Text Entities

    ERIC Educational Resources Information Center

    Popa, Marius

    2006-01-01

    The paper highlights some evaluation methods to assess the quality characteristics of the text entities. The main concepts used in building and evaluation processes of the text entities are presented. Also, some aggregated metrics for orthogonality measurements are presented. The evaluation process for automatic evaluation of the text entities is…

  9. [Coupling coordination evaluation method between eco-environment quality and economic development level in contiguous special poverty-stricken areas of China].

    PubMed

    Wang, Yan-hui; Li, Jing-yi

    2015-05-01

    It is one of the important strategies in the new period of national poverty alleviation and development to maintain the basic balance between the ecological environment and economic development, and to promote the coordinated sustainable development of economy and ecological environment. Taking six contiguous special poverty-stricken areas as the study areas, a coupling coordination evaluation method between eco-environment quality and economic development level in contiguous special poverty-stricken areas was explored in this paper. The region' s ecological poverty index system was proposed based on the natural attribute of ecological environment, and the ecological environment quality evaluation method was built up by using AHP weighting method, followed by the design of the coupling coordination evaluation method between the ecological environment indices and the county economic poverty comprehensive indices. The coupling coordination degrees were calculated and their spatial representation differentiations were analyzed respectively at district, province, city, and county scales. Results showed that approximately half of the counties in the study areas achieved the harmoniously coordinated development. However, the ecological environmental quality and the economic development in most counties could not be synchronized, where mountains, rivers and other geographic features existed roughly as a dividing line of the coordinated development types. The phenomena of dislocation between the ecological environment and economic development in state-level poor counties were more serious than those of local poor counties.

  10. Analytical Methods to Evaluate the Quality of Edible Fats and Oils: The JOCS Standard Methods for Analysis of Fats, Oils and Related Materials (2013) and Advanced Methods.

    PubMed

    Endo, Yasushi

    2018-01-01

    Edible fats and oils are among the basic components of the human diet, along with carbohydrates and proteins, and they are the source of high energy and essential fatty acids such as linoleic and linolenic acids. Edible fats and oils are used in for pan- and deep-frying, and in salad dressing, mayonnaise and processed foods such as chocolates and cream. The physical and chemical properties of edible fats and oils can affect the quality of oil foods and hence must be evaluated in detail. The physical characteristics of edible fats and oils include color, specific gravity, refractive index, melting point, congeal point, smoke point, flash point, fire point, and viscosity, while the chemical characteristics include acid value, saponification value, iodine value, fatty acid composition, trans isomers, triacylglycerol composition, unsaponifiable matters (sterols, tocopherols) and minor components (phospholipids, chlorophyll pigments, glycidyl fatty acid esters). Peroxide value, p-anisidine value, carbonyl value, polar compounds and polymerized triacylglycerols are indexes of the deterioration of edible fats and oils. This review describes the analytical methods to evaluate the quality of edible fats and oils, especially the Standard Methods for Analysis of Fats, Oils and Related Materials edited by Japan Oil Chemists' Society (the JOCS standard methods) and advanced methods.

  11. [Research on evolution and transition of quality evaluation of Shihu].

    PubMed

    Zhao, Yu-Jiao; Han, Bang-Xing; Peng, Hua-Sheng; Peng, Dai-Yin

    2016-04-01

    Shihu is one of the most valuable Chinese medicines in China. The sources of Shihu are complex and the quality evaluation of it mainly depends on morphologic characteristics distinction. In order to understand the Shihu's quality evaluation concept of Chinese herbalists in the past dynasties. This paper summarizes the methods of quality evaluation in ancient bencao systematically. The ancient bencao records that the quality of Shihu is closely related to its germplasm, habitat, processing and character. The concept of germplasm about shihu includes generalized and narrow sense, besides, the clinical applications of Dendrobium huoshanenese, D. officinale and D. nobile are focused on different diseases. D. huoshanenese has been regarded as Dao-di herbs since Qing Dynasty. The main products of Shihu contain fresh goods and dry goods, their clinical applications are also treated differently. Fengdou is one of the commodity specifications in Shihu. Its processing method probably dated from the Qing Dynasty, but now, it has become the mainstream commodityform. There was a common sense that different kinds of Shihu owed different characters and curative effects in ancient bencao, and the quality would enhance with the increasing viscidity. Therefore, the "Germplasm", "Geoherbs", "processing", "characters" were integrated into traditional quality evaluation methods of Shihu. Meanwhile, we should pay attention to the clinical efficacy of shihu with different species and processing methods. Copyright© by the Chinese Pharmaceutical Association.

  12. Evaluating online data of water quality changes in a pilot drinking water distribution system with multivariate data exploration methods.

    PubMed

    Mustonen, Satu M; Tissari, Soile; Huikko, Laura; Kolehmainen, Mikko; Lehtola, Markku J; Hirvonen, Arja

    2008-05-01

    The distribution of drinking water generates soft deposits and biofilms in the pipelines of distribution systems. Disturbances in water distribution can detach these deposits and biofilms and thus deteriorate the water quality. We studied the effects of simulated pressure shocks on the water quality with online analysers. The study was conducted with copper and composite plastic pipelines in a pilot distribution system. The online data gathered during the study was evaluated with Self-Organising Map (SOM) and Sammon's mapping, which are useful methods in exploring large amounts of multivariate data. The objective was to test the usefulness of these methods in pinpointing the abnormal water quality changes in the online data. The pressure shocks increased temporarily the number of particles, turbidity and electrical conductivity. SOM and Sammon's mapping were able to separate these situations from the normal data and thus make those visible. Therefore these methods make it possible to detect abrupt changes in water quality and thus to react rapidly to any disturbances in the system. These methods are useful in developing alert systems and predictive applications connected to online monitoring.

  13. Color image definition evaluation method based on deep learning method

    NASA Astrophysics Data System (ADS)

    Liu, Di; Li, YingChun

    2018-01-01

    In order to evaluate different blurring levels of color image and improve the method of image definition evaluation, this paper proposed a method based on the depth learning framework and BP neural network classification model, and presents a non-reference color image clarity evaluation method. Firstly, using VGG16 net as the feature extractor to extract 4,096 dimensions features of the images, then the extracted features and labeled images are employed in BP neural network to train. And finally achieve the color image definition evaluation. The method in this paper are experimented by using images from the CSIQ database. The images are blurred at different levels. There are 4,000 images after the processing. Dividing the 4,000 images into three categories, each category represents a blur level. 300 out of 400 high-dimensional features are trained in VGG16 net and BP neural network, and the rest of 100 samples are tested. The experimental results show that the method can take full advantage of the learning and characterization capability of deep learning. Referring to the current shortcomings of the major existing image clarity evaluation methods, which manually design and extract features. The method in this paper can extract the images features automatically, and has got excellent image quality classification accuracy for the test data set. The accuracy rate is 96%. Moreover, the predicted quality levels of original color images are similar to the perception of the human visual system.

  14. Evaluation of the communication quality of free-space laser communication based on the power-in-the-bucket method.

    PubMed

    Yin, Xianghui; Wang, Rui; Wang, Shaoxin; Wang, Yukun; Jin, Chengbin; Cao, Zhaoliang; Xuan, Li

    2018-02-01

    Atmospheric turbulence seriously affects the quality of free-space laser communication. The Strehl ratio (SR) is used to evaluate the effect of atmospheric turbulence on the receiving energy of free-space laser communication systems. However, the SR method does not consider the area of the laser-receiving end face. In this study, the power-in-the-bucket (PIB) method is demonstrated to accurately evaluate the effect of turbulence on the receiving energy. A theoretical equation is first obtained to calculate PIB. Simulated and experimental validations are then performed to verify the effectiveness of the theoretical equation. This work may provide effective guidance for the design and evaluation of free-space laser communication systems.

  15. A rating scale is a proper method to evaluate changes in quality of life due to dry eye symptoms.

    PubMed

    Xue, Wenwen; Xu, Xian; Zou, Haidong

    2018-02-07

    To determine which utility value assessment method is more suitable to evaluate changes in the quality of life due to dry eye symptoms. Dry eye outpatients with a presenting visual acuity of 20/25 or better in the worse-seeing eye were recruited. Presenting distance visual acuity, tear film break-up time, Schirmer I test and fluorescein were assessed. The severity of dry eye symptoms was assessed using the Ocular Surface Disease Index (OSDI), and utility values were measured using the time trade-off (TTO), standard gamble (SG1 and SG2) and rating scale (RS) methods. Different utility values were compared with each other. The most appropriate utility value method to evaluate quality-of-life changes solely due to dry eye symptoms is determined by calculating the correlation between the OSDI score and different utility values. A total of 104 patients were enrolled. The three sections of OSDI in the order of high to low scores were as follows: "environmental trigger," "eye discomfort" and "visual function." The utility scores measured with TTO, SG1, SG2 and RS were 0.95 ± 0.11, 0.96 ± 0.10, 0.99 ± 0.07 and 0.89 ± 0.10, respectively. The utility scores evaluated by the TTO, SG1, SG2 and RS methods were significantly different from each other (p < 0.05). Only the utility scores measured with RS were significantly correlated with the composite OSDI score, "environmental trigger" and "eye discomfort" section scores (p < 0.05). RS is more sensitive than TTO and SG for the evaluation of altered quality of life due to dry eye symptoms.

  16. Evaluation of the sparse coding super-resolution method for improving image quality of up-sampled images in computed tomography

    NASA Astrophysics Data System (ADS)

    Ota, Junko; Umehara, Kensuke; Ishimaru, Naoki; Ohno, Shunsuke; Okamoto, Kentaro; Suzuki, Takanori; Shirai, Naoki; Ishida, Takayuki

    2017-02-01

    As the capability of high-resolution displays grows, high-resolution images are often required in Computed Tomography (CT). However, acquiring high-resolution images takes a higher radiation dose and a longer scanning time. In this study, we applied the Sparse-coding-based Super-Resolution (ScSR) method to generate high-resolution images without increasing the radiation dose. We prepared the over-complete dictionary learned the mapping between low- and highresolution patches and seek a sparse representation of each patch of the low-resolution input. These coefficients were used to generate the high-resolution output. For evaluation, 44 CT cases were used as the test dataset. We up-sampled images up to 2 or 4 times and compared the image quality of the ScSR scheme and bilinear and bicubic interpolations, which are the traditional interpolation schemes. We also compared the image quality of three learning datasets. A total of 45 CT images, 91 non-medical images, and 93 chest radiographs were used for dictionary preparation respectively. The image quality was evaluated by measuring peak signal-to-noise ratio (PSNR) and structure similarity (SSIM). The differences of PSNRs and SSIMs between the ScSR method and interpolation methods were statistically significant. Visual assessment confirmed that the ScSR method generated a high-resolution image with sharpness, whereas conventional interpolation methods generated over-smoothed images. To compare three different training datasets, there were no significance between the CT, the CXR and non-medical datasets. These results suggest that the ScSR provides a robust approach for application of up-sampling CT images and yields substantial high image quality of extended images in CT.

  17. Data envelopment analysis in service quality evaluation: an empirical study

    NASA Astrophysics Data System (ADS)

    Najafi, Seyedvahid; Saati, Saber; Tavana, Madjid

    2015-09-01

    Service quality is often conceptualized as the comparison between service expectations and the actual performance perceptions. It enhances customer satisfaction, decreases customer defection, and promotes customer loyalty. Substantial literature has examined the concept of service quality, its dimensions, and measurement methods. We introduce the perceived service quality index (PSQI) as a single measure for evaluating the multiple-item service quality construct based on the SERVQUAL model. A slack-based measure (SBM) of efficiency with constant inputs is used to calculate the PSQI. In addition, a non-linear programming model based on the SBM is proposed to delineate an improvement guideline and improve service quality. An empirical study is conducted to assess the applicability of the method proposed in this study. A large number of studies have used DEA as a benchmarking tool to measure service quality. These models do not propose a coherent performance evaluation construct and consequently fail to deliver improvement guidelines for improving service quality. The DEA models proposed in this study are designed to evaluate and improve service quality within a comprehensive framework and without any dependency on external data.

  18. Influences on Evaluation Quality

    ERIC Educational Resources Information Center

    Cooksy, Leslie J.; Mark, Melvin M.

    2012-01-01

    Attention to evaluation quality is commonplace, even if sometimes implicit. Drawing on her 2010 Presidential Address to the American Evaluation Association, Leslie Cooksy suggests that evaluation quality depends, at least in part, on the intersection of three factors: (a) evaluator competency, (b) aspects of the evaluation environment or context,…

  19. [Methodological quality and reporting quality evaluation of randomized controlled trials published in China Journal of Chinese Materia Medica].

    PubMed

    Yu, Dan-Dan; Xie, Yan-Ming; Liao, Xing; Zhi, Ying-Jie; Jiang, Jun-Jie; Chen, Wei

    2018-02-01

    To evaluate the methodological quality and reporting quality of randomized controlled trials(RCTs) published in China Journal of Chinese Materia Medica, we searched CNKI and China Journal of Chinese Materia webpage to collect RCTs since the establishment of the magazine. The Cochrane risk of bias assessment tool was used to evaluate the methodological quality of RCTs. The CONSORT 2010 list was adopted as reporting quality evaluating tool. Finally, 184 RCTs were included and evaluated methodologically, of which 97 RCTs were evaluated with reporting quality. For the methodological evaluating, 62 trials(33.70%) reported the random sequence generation; 9(4.89%) trials reported the allocation concealment; 25(13.59%) trials adopted the method of blinding; 30(16.30%) trials reported the number of patients withdrawing, dropping out and those lost to follow-up;2 trials (1.09%) reported trial registration and none of the trial reported the trial protocol; only 8(4.35%) trials reported the sample size estimation in details. For reporting quality appraising, 3 reporting items of 25 items were evaluated with high-quality,including: abstract, participants qualified criteria, and statistical methods; 4 reporting items with medium-quality, including purpose, intervention, random sequence method, and data collection of sites and locations; 9 items with low-quality reporting items including title, backgrounds, random sequence types, allocation concealment, blindness, recruitment of subjects, baseline data, harms, and funding;the rest of items were of extremely low quality(the compliance rate of reporting item<10%). On the whole, the methodological and reporting quality of RCTs published in the magazine are generally low. Further improvement in both methodological and reporting quality for RCTs of traditional Chinese medicine are warranted. It is recommended that the international standards and procedures for RCT design should be strictly followed to conduct high-quality trials

  20. Introducing quality improvement methods into local public health departments: structured evaluation of a statewide pilot project.

    PubMed

    Riley, William; Parsons, Helen; McCoy, Kim; Burns, Debra; Anderson, Donna; Lee, Suhna; Sainfort, François

    2009-10-01

    To test the feasibility and assess the preliminary impact of a unique statewide quality improvement (QI) training program designed for public health departments. One hundred and ninety-five public health employees/managers from 38 local health departments throughout Minnesota were selected to participate in a newly developed QI training program and 65 of those engaged in and completed eight expert-supported QI projects over a period of 10 months from June 2007 through March 2008. As part of the Minnesota Quality Improvement Initiative, a structured distance education QI training program was designed and deployed in a first large-scale pilot. To evaluate the preliminary impact of the program, a mixed-method evaluation design was used based on four dimensions: learner reaction, knowledge, intention to apply, and preliminary outcomes. Subjective ratings of three dimensions of training quality were collected from participants after each of the scheduled learning sessions. Pre- and post-QI project surveys were administered to collect participant reactions, knowledge, future intention to apply learning, and perceived outcomes. Monthly and final QI project reports were collected to further inform success and preliminary outcomes of the projects. The participants reported (1) high levels of satisfaction with the training sessions, (2) increased perception of the relevance of the QI techniques, (3) increased perceived knowledge of all specific QI methods and techniques, (4) increased confidence in applying QI techniques on future projects, (5) increased intention to apply techniques on future QI projects, and (6) high perceived success of, and satisfaction with, the projects. Finally, preliminary outcomes data show moderate to large improvements in quality and/or efficiency for six out of eight projects. QI methods and techniques can be successfully implemented in local public health agencies on a statewide basis using the collaborative model through distance training and

  1. Quality Evaluation of Potentilla fruticosa L. by High Performance Liquid Chromatography Fingerprinting Associated with Chemometric Methods.

    PubMed

    Liu, Wei; Wang, Dongmei; Liu, Jianjun; Li, Dengwu; Yin, Dongxue

    2016-01-01

    The present study was performed to assess the quality of Potentilla fruticosa L. sampled from distinct regions of China using high performance liquid chromatography (HPLC) fingerprinting coupled with a suite of chemometric methods. For this quantitative analysis, the main active phytochemical compositions and the antioxidant activity in P. fruticosa were also investigated. Considering the high percentages and antioxidant activities of phytochemicals, P. fruticosa samples from Kangding, Sichuan were selected as the most valuable raw materials. Similarity analysis (SA) of HPLC fingerprints, hierarchical cluster analysis (HCA), principle component analysis (PCA), and discriminant analysis (DA) were further employed to provide accurate classification and quality estimates of P. fruticosa. Two principal components (PCs) were collected by PCA. PC1 separated samples from Kangding, Sichuan, capturing 57.64% of the variance, whereas PC2 contributed to further separation, capturing 18.97% of the variance. Two kinds of discriminant functions with a 100% discrimination ratio were constructed. The results strongly supported the conclusion that the eight samples from different regions were clustered into three major groups, corresponding with their morphological classification, for which HPLC analysis confirmed the considerable variation in phytochemical compositions and that P. fruticosa samples from Kangding, Sichuan were of high quality. The results of SA, HCA, PCA, and DA were in agreement and performed well for the quality assessment of P. fruticosa. Consequently, HPLC fingerprinting coupled with chemometric techniques provides a highly flexible and reliable method for the quality evaluation of traditional Chinese medicines.

  2. Quality Evaluation of Potentilla fruticosa L. by High Performance Liquid Chromatography Fingerprinting Associated with Chemometric Methods

    PubMed Central

    Liu, Wei; Wang, Dongmei; Liu, Jianjun; Li, Dengwu; Yin, Dongxue

    2016-01-01

    The present study was performed to assess the quality of Potentilla fruticosa L. sampled from distinct regions of China using high performance liquid chromatography (HPLC) fingerprinting coupled with a suite of chemometric methods. For this quantitative analysis, the main active phytochemical compositions and the antioxidant activity in P. fruticosa were also investigated. Considering the high percentages and antioxidant activities of phytochemicals, P. fruticosa samples from Kangding, Sichuan were selected as the most valuable raw materials. Similarity analysis (SA) of HPLC fingerprints, hierarchical cluster analysis (HCA), principle component analysis (PCA), and discriminant analysis (DA) were further employed to provide accurate classification and quality estimates of P. fruticosa. Two principal components (PCs) were collected by PCA. PC1 separated samples from Kangding, Sichuan, capturing 57.64% of the variance, whereas PC2 contributed to further separation, capturing 18.97% of the variance. Two kinds of discriminant functions with a 100% discrimination ratio were constructed. The results strongly supported the conclusion that the eight samples from different regions were clustered into three major groups, corresponding with their morphological classification, for which HPLC analysis confirmed the considerable variation in phytochemical compositions and that P. fruticosa samples from Kangding, Sichuan were of high quality. The results of SA, HCA, PCA, and DA were in agreement and performed well for the quality assessment of P. fruticosa. Consequently, HPLC fingerprinting coupled with chemometric techniques provides a highly flexible and reliable method for the quality evaluation of traditional Chinese medicines. PMID:26890416

  3. Projection pursuit water quality evaluation model based on chicken swam algorithm

    NASA Astrophysics Data System (ADS)

    Hu, Zhe

    2018-03-01

    In view of the uncertainty and ambiguity of each index in water quality evaluation, in order to solve the incompatibility of evaluation results of individual water quality indexes, a projection pursuit model based on chicken swam algorithm is proposed. The projection index function which can reflect the water quality condition is constructed, the chicken group algorithm (CSA) is introduced, the projection index function is optimized, the best projection direction of the projection index function is sought, and the best projection value is obtained to realize the water quality evaluation. The comparison between this method and other methods shows that it is reasonable and feasible to provide decision-making basis for water pollution control in the basin.

  4. Imaging quality evaluation method of pixel coupled electro-optical imaging system

    NASA Astrophysics Data System (ADS)

    He, Xu; Yuan, Li; Jin, Chunqi; Zhang, Xiaohui

    2017-09-01

    With advancements in high-resolution imaging optical fiber bundle fabrication technology, traditional photoelectric imaging system have become ;flexible; with greatly reduced volume and weight. However, traditional image quality evaluation models are limited by the coupling discrete sampling effect of fiber-optic image bundles and charge-coupled device (CCD) pixels. This limitation substantially complicates the design, optimization, assembly, and evaluation image quality of the coupled discrete sampling imaging system. Based on the transfer process of grayscale cosine distribution optical signal in the fiber-optic image bundle and CCD, a mathematical model of coupled modulation transfer function (coupled-MTF) is established. This model can be used as a basis for following studies on the convergence and periodically oscillating characteristics of the function. We also propose the concept of the average coupled-MTF, which is consistent with the definition of traditional MTF. Based on this concept, the relationships among core distance, core layer radius, and average coupled-MTF are investigated.

  5. Study on an Air Quality Evaluation Model for Beijing City Under Haze-Fog Pollution Based on New Ambient Air Quality Standards

    PubMed Central

    Li, Li; Liu, Dong-Jun

    2014-01-01

    Since 2012, China has been facing haze-fog weather conditions, and haze-fog pollution and PM2.5 have become hot topics. It is very necessary to evaluate and analyze the ecological status of the air environment of China, which is of great significance for environmental protection measures. In this study the current situation of haze-fog pollution in China was analyzed first, and the new Ambient Air Quality Standards were introduced. For the issue of air quality evaluation, a comprehensive evaluation model based on an entropy weighting method and nearest neighbor method was developed. The entropy weighting method was used to determine the weights of indicators, and the nearest neighbor method was utilized to evaluate the air quality levels. Then the comprehensive evaluation model was applied into the practical evaluation problems of air quality in Beijing to analyze the haze-fog pollution. Two simulation experiments were implemented in this study. One experiment included the indicator of PM2.5 and was carried out based on the new Ambient Air Quality Standards (GB 3095-2012); the other experiment excluded PM2.5 and was carried out based on the old Ambient Air Quality Standards (GB 3095-1996). Their results were compared, and the simulation results showed that PM2.5 was an important indicator for air quality and the evaluation results of the new Air Quality Standards were more scientific than the old ones. The haze-fog pollution situation in Beijing City was also analyzed based on these results, and the corresponding management measures were suggested. PMID:25170682

  6. A semi-automated tool for treatment plan-quality evaluation and clinical trial quality assurance

    NASA Astrophysics Data System (ADS)

    Wang, Jiazhou; Chen, Wenzhou; Studenski, Matthew; Cui, Yunfeng; Lee, Andrew J.; Xiao, Ying

    2013-07-01

    The goal of this work is to develop a plan-quality evaluation program for clinical routine and multi-institutional clinical trials so that the overall evaluation efficiency is improved. In multi-institutional clinical trials evaluating the plan quality is a time-consuming and labor-intensive process. In this note, we present a semi-automated plan-quality evaluation program which combines MIMVista, Java/MATLAB, and extensible markup language (XML). More specifically, MIMVista is used for data visualization; Java and its powerful function library are implemented for calculating dosimetry parameters; and to improve the clarity of the index definitions, XML is applied. The accuracy and the efficiency of the program were evaluated by comparing the results of the program with the manually recorded results in two RTOG trials. A slight difference of about 0.2% in volume or 0.6 Gy in dose between the semi-automated program and manual recording was observed. According to the criteria of indices, there are minimal differences between the two methods. The evaluation time is reduced from 10-20 min to 2 min by applying the semi-automated plan-quality evaluation program.

  7. Predictive analysis of beer quality by correlating sensory evaluation with higher alcohol and ester production using multivariate statistics methods.

    PubMed

    Dong, Jian-Jun; Li, Qing-Liang; Yin, Hua; Zhong, Cheng; Hao, Jun-Guang; Yang, Pan-Fei; Tian, Yu-Hong; Jia, Shi-Ru

    2014-10-15

    Sensory evaluation is regarded as a necessary procedure to ensure a reproducible quality of beer. Meanwhile, high-throughput analytical methods provide a powerful tool to analyse various flavour compounds, such as higher alcohol and ester. In this study, the relationship between flavour compounds and sensory evaluation was established by non-linear models such as partial least squares (PLS), genetic algorithm back-propagation neural network (GA-BP), support vector machine (SVM). It was shown that SVM with a Radial Basis Function (RBF) had a better performance of prediction accuracy for both calibration set (94.3%) and validation set (96.2%) than other models. Relatively lower prediction abilities were observed for GA-BP (52.1%) and PLS (31.7%). In addition, the kernel function of SVM played an essential role of model training when the prediction accuracy of SVM with polynomial kernel function was 32.9%. As a powerful multivariate statistics method, SVM holds great potential to assess beer quality. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Quality Evaluation of Land-Cover Classification Using Convolutional Neural Network

    NASA Astrophysics Data System (ADS)

    Dang, Y.; Zhang, J.; Zhao, Y.; Luo, F.; Ma, W.; Yu, F.

    2018-04-01

    Land-cover classification is one of the most important products of earth observation, which focuses mainly on profiling the physical characters of the land surface with temporal and distribution attributes and contains the information of both natural and man-made coverage elements, such as vegetation, soil, glaciers, rivers, lakes, marsh wetlands and various man-made structures. In recent years, the amount of high-resolution remote sensing data has increased sharply. Accordingly, the volume of land-cover classification products increases, as well as the need to evaluate such frequently updated products that is a big challenge. Conventionally, the automatic quality evaluation of land-cover classification is made through pixel-based classifying algorithms, which lead to a much trickier task and consequently hard to keep peace with the required updating frequency. In this paper, we propose a novel quality evaluation approach for evaluating the land-cover classification by a scene classification method Convolutional Neural Network (CNN) model. By learning from remote sensing data, those randomly generated kernels that serve as filter matrixes evolved to some operators that has similar functions to man-crafted operators, like Sobel operator or Canny operator, and there are other kernels learned by the CNN model that are much more complex and can't be understood as existing filters. The method using CNN approach as the core algorithm serves quality-evaluation tasks well since it calculates a bunch of outputs which directly represent the image's membership grade to certain classes. An automatic quality evaluation approach for the land-cover DLG-DOM coupling data (DLG for Digital Line Graphic, DOM for Digital Orthophoto Map) will be introduced in this paper. The CNN model as an robustness method for image evaluation, then brought out the idea of an automatic quality evaluation approach for land-cover classification. Based on this experiment, new ideas of quality evaluation

  9. Evaluation of statistical methods for quantifying fractal scaling in water-quality time series with irregular sampling

    NASA Astrophysics Data System (ADS)

    Zhang, Qian; Harman, Ciaran J.; Kirchner, James W.

    2018-02-01

    River water-quality time series often exhibit fractal scaling, which here refers to autocorrelation that decays as a power law over some range of scales. Fractal scaling presents challenges to the identification of deterministic trends because (1) fractal scaling has the potential to lead to false inference about the statistical significance of trends and (2) the abundance of irregularly spaced data in water-quality monitoring networks complicates efforts to quantify fractal scaling. Traditional methods for estimating fractal scaling - in the form of spectral slope (β) or other equivalent scaling parameters (e.g., Hurst exponent) - are generally inapplicable to irregularly sampled data. Here we consider two types of estimation approaches for irregularly sampled data and evaluate their performance using synthetic time series. These time series were generated such that (1) they exhibit a wide range of prescribed fractal scaling behaviors, ranging from white noise (β = 0) to Brown noise (β = 2) and (2) their sampling gap intervals mimic the sampling irregularity (as quantified by both the skewness and mean of gap-interval lengths) in real water-quality data. The results suggest that none of the existing methods fully account for the effects of sampling irregularity on β estimation. First, the results illustrate the danger of using interpolation for gap filling when examining autocorrelation, as the interpolation methods consistently underestimate or overestimate β under a wide range of prescribed β values and gap distributions. Second, the widely used Lomb-Scargle spectral method also consistently underestimates β. A previously published modified form, using only the lowest 5 % of the frequencies for spectral slope estimation, has very poor precision, although the overall bias is small. Third, a recent wavelet-based method, coupled with an aliasing filter, generally has the smallest bias and root-mean-squared error among all methods for a wide range of

  10. Quality evaluation of fish and other seafood by traditional and nondestructive instrumental methods: Advantages and limitations.

    PubMed

    Hassoun, Abdo; Karoui, Romdhane

    2017-06-13

    Although being one of the most vulnerable and perishable products, fish and other seafoods provide a wide range of health-promoting compounds. Recently, the growing interest of consumers in food quality and safety issues has contributed to the increasing demand for sensitive and rapid analytical technologies. Several traditional physicochemical, textural, sensory, and electrical methods have been used to evaluate freshness and authentication of fish and other seafood products. Despite the importance of these standard methods, they are expensive and time-consuming, and often susceptible to large sources of variation. Recently, spectroscopic methods and other emerging techniques have shown great potential due to speed of analysis, minimal sample preparation, high repeatability, low cost, and, most of all, the fact that these techniques are noninvasive and nondestructive and, therefore, could be applied to any online monitoring system. This review describes firstly and briefly the basic principles of multivariate data analysis, followed by the most commonly traditional methods used for the determination of the freshness and authenticity of fish and other seafood products. A special focus is put on the use of rapid and nondestructive techniques (spectroscopic techniques and instrumental sensors) to address several issues related to the quality of these products. Moreover, the advantages and limitations of each technique are reviewed and some perspectives are also given.

  11. Video quality assessment method motivated by human visual perception

    NASA Astrophysics Data System (ADS)

    He, Meiling; Jiang, Gangyi; Yu, Mei; Song, Yang; Peng, Zongju; Shao, Feng

    2016-11-01

    Research on video quality assessment (VQA) plays a crucial role in improving the efficiency of video coding and the performance of video processing. It is well acknowledged that the motion energy model generates motion energy responses in a middle temporal area by simulating the receptive field of neurons in V1 for the motion perception of the human visual system. Motivated by the biological evidence for the visual motion perception, a VQA method is proposed in this paper, which comprises the motion perception quality index and the spatial index. To be more specific, the motion energy model is applied to evaluate the temporal distortion severity of each frequency component generated from the difference of Gaussian filter bank, which produces the motion perception quality index, and the gradient similarity measure is used to evaluate the spatial distortion of the video sequence to get the spatial quality index. The experimental results of the LIVE, CSIQ, and IVP video databases demonstrate that the random forests regression technique trained by the generated quality indices is highly correspondent to human visual perception and has many significant improvements than comparable well-performing methods. The proposed method has higher consistency with subjective perception and higher generalization capability.

  12. Iodine absorption cells quality evaluation methods

    NASA Astrophysics Data System (ADS)

    Hrabina, Jan; Zucco, Massimo; Holá, Miroslava; Šarbort, Martin; Acef, Ouali; Du-Burck, Frédéric; Lazar, Josef; Číp, Ondřej

    2016-12-01

    The absorption cells represent an unique tool for the laser frequency stabilization. They serve as irreplaceable optical frequency references in realization of high-stable laser standards and laser sources for different brands of optical measurements, including the most precise frequency and dimensional measurement systems. One of the most often used absorption media covering visible and near IR spectral range is molecular iodine. It offers rich atlas of very strong and narrow spectral transitions which allow realization of laser systems with ultimate frequency stabilities in or below 10-14 order level. One of the most often disccussed disadvantage of the iodine cells is iodine's corrosivity and sensitivity to presence of foreign substances. The impurities react with absorption media and cause spectral shifts of absorption spectra, spectral broadening of the transitions and decrease achievable signal-to-noise ratio of the detected spectra. All of these unwanted effects directly influence frequency stability of the realized laser standard and due to this fact, the quality of iodine cells must be precisely controlled. We present a comparison of traditionally used method of laser induced fluorescence (LIF) with novel technique based on hyperfine transitions linewidths measurement. The results summarize advantages and drawbacks of these techniques and give a recommendation for their practical usage.

  13. Methods for computing water-quality loads at sites in the U.S. Geological Survey National Water Quality Network

    USGS Publications Warehouse

    Lee, Casey J.; Murphy, Jennifer C.; Crawford, Charles G.; Deacon, Jeffrey R.

    2017-10-24

    The U.S. Geological Survey publishes information on concentrations and loads of water-quality constituents at 111 sites across the United States as part of the U.S. Geological Survey National Water Quality Network (NWQN). This report details historical and updated methods for computing water-quality loads at NWQN sites. The primary updates to historical load estimation methods include (1) an adaptation to methods for computing loads to the Gulf of Mexico; (2) the inclusion of loads computed using the Weighted Regressions on Time, Discharge, and Season (WRTDS) method; and (3) the inclusion of loads computed using continuous water-quality data. Loads computed using WRTDS and continuous water-quality data are provided along with those computed using historical methods. Various aspects of method updates are evaluated in this report to help users of water-quality loading data determine which estimation methods best suit their particular application.

  14. Subjective quality evaluation of low-bit-rate video

    NASA Astrophysics Data System (ADS)

    Masry, Mark; Hemami, Sheila S.; Osberger, Wilfried M.; Rohaly, Ann M.

    2001-06-01

    A subjective quality evaluation was performed to qualify vie4wre responses to visual defects that appear in low bit rate video at full and reduced frame rates. The stimuli were eight sequences compressed by three motion compensated encoders - Sorenson Video, H.263+ and a Wavelet based coder - operating at five bit/frame rate combinations. The stimulus sequences exhibited obvious coding artifacts whose nature differed across the three coders. The subjective evaluation was performed using the Single Stimulus Continuos Quality Evaluation method of UTI-R Rec. BT.500-8. Viewers watched concatenated coded test sequences and continuously registered the perceived quality using a slider device. Data form 19 viewers was colleted. An analysis of their responses to the presence of various artifacts across the range of possible coding conditions and content is presented. The effects of blockiness and blurriness on perceived quality are examined. The effects of changes in frame rate on perceived quality are found to be related to the nature of the motion in the sequence.

  15. Information Quality Evaluation of C2 Systems at Architecture Level

    DTIC Science & Technology

    2014-06-01

    based on architecture models of C2 systems, which can help to identify key factors impacting information quality and improve the system capability at the stage of architecture design of C2 system....capability evaluation of C2 systems at architecture level becomes necessary and important for improving the system capability at the stage of architecture ... design . This paper proposes a method for information quality evaluation of C2 system at architecture level. First, the information quality model is

  16. The Quality of Methods Reporting in Parasitology Experiments

    PubMed Central

    Flórez-Vargas, Oscar; Bramhall, Michael; Noyes, Harry; Cruickshank, Sheena; Stevens, Robert; Brass, Andy

    2014-01-01

    There is a growing concern both inside and outside the scientific community over the lack of reproducibility of experiments. The depth and detail of reported methods are critical to the reproducibility of findings, but also for making it possible to compare and integrate data from different studies. In this study, we evaluated in detail the methods reporting in a comprehensive set of trypanosomiasis experiments that should enable valid reproduction, integration and comparison of research findings. We evaluated a subset of other parasitic (Leishmania, Toxoplasma, Plasmodium, Trichuris and Schistosoma) and non-parasitic (Mycobacterium) experimental infections in order to compare the quality of method reporting more generally. A systematic review using PubMed (2000–2012) of all publications describing gene expression in cells and animals infected with Trypanosoma spp was undertaken based on PRISMA guidelines; 23 papers were identified and included. We defined a checklist of essential parameters that should be reported and have scored the number of those parameters that are reported for each publication. Bibliometric parameters (impact factor, citations and h-index) were used to look for association between Journal and Author status and the quality of method reporting. Trichuriasis experiments achieved the highest scores and included the only paper to score 100% in all criteria. The mean of scores achieved by Trypanosoma articles through the checklist was 65.5% (range 32–90%). Bibliometric parameters were not correlated with the quality of method reporting (Spearman's rank correlation coefficient <−0.5; p>0.05). Our results indicate that the quality of methods reporting in experimental parasitology is a cause for concern and it has not improved over time, despite there being evidence that most of the assessed parameters do influence the results. We propose that our set of parameters be used as guidelines to improve the quality of the reporting of experimental

  17. The quality of methods reporting in parasitology experiments.

    PubMed

    Flórez-Vargas, Oscar; Bramhall, Michael; Noyes, Harry; Cruickshank, Sheena; Stevens, Robert; Brass, Andy

    2014-01-01

    There is a growing concern both inside and outside the scientific community over the lack of reproducibility of experiments. The depth and detail of reported methods are critical to the reproducibility of findings, but also for making it possible to compare and integrate data from different studies. In this study, we evaluated in detail the methods reporting in a comprehensive set of trypanosomiasis experiments that should enable valid reproduction, integration and comparison of research findings. We evaluated a subset of other parasitic (Leishmania, Toxoplasma, Plasmodium, Trichuris and Schistosoma) and non-parasitic (Mycobacterium) experimental infections in order to compare the quality of method reporting more generally. A systematic review using PubMed (2000-2012) of all publications describing gene expression in cells and animals infected with Trypanosoma spp was undertaken based on PRISMA guidelines; 23 papers were identified and included. We defined a checklist of essential parameters that should be reported and have scored the number of those parameters that are reported for each publication. Bibliometric parameters (impact factor, citations and h-index) were used to look for association between Journal and Author status and the quality of method reporting. Trichuriasis experiments achieved the highest scores and included the only paper to score 100% in all criteria. The mean of scores achieved by Trypanosoma articles through the checklist was 65.5% (range 32-90%). Bibliometric parameters were not correlated with the quality of method reporting (Spearman's rank correlation coefficient <-0.5; p>0.05). Our results indicate that the quality of methods reporting in experimental parasitology is a cause for concern and it has not improved over time, despite there being evidence that most of the assessed parameters do influence the results. We propose that our set of parameters be used as guidelines to improve the quality of the reporting of experimental infection

  18. Software component quality evaluation

    NASA Technical Reports Server (NTRS)

    Clough, A. J.

    1991-01-01

    The paper describes a software inspection process that can be used to evaluate the quality of software components. Quality criteria, process application, independent testing of the process and proposed associated tool support are covered. Early results indicate that this technique is well suited for assessing software component quality in a standardized fashion. With automated machine assistance to facilitate both the evaluation and selection of software components, such a technique should promote effective reuse of software components.

  19. Evaluating co-creation of knowledge: from quality criteria and indicators to methods

    NASA Astrophysics Data System (ADS)

    Schuck-Zöller, Susanne; Cortekar, Jörg; Jacob, Daniela

    2017-11-01

    Basic research in the natural sciences rests on a long tradition of evaluation. However, since the San Francisco Declaration on Research Assessment (DORA) came out in 2012, there has been intense discussion in the natural sciences, above all amongst researchers and funding agencies in the different fields of applied research and scientific service. This discussion was intensified when climate services and other fields, used to make users participate in research and development activities (co-creation), demanded new evaluation methods appropriate to this new research mode. This paper starts by describing a comprehensive and interdisciplinary literature overview of indicators to evaluate co-creation of knowledge, including the different fields of integrated knowledge production. Then the authors harmonize the different elements of evaluation from literature in an evaluation cascade that scales down from very general evaluation dimensions to tangible assessment methods. They describe evaluation indicators already being documented and include a mixture of different assessment methods for two exemplary criteria. It is shown what can be deduced from already existing methodology for climate services and envisaged how climate services can further to develop their specific evaluation method.

  20. Evaluating new HbA1c methods for adoption by the IFCC and NGSP reference networks using international quality targets.

    PubMed

    Lenters-Westra, Erna; English, Emma

    2017-08-28

    As a reference laboratory for HbA1c, it is essential to have accurate and precise HbA1c methods covering a range of measurement principles. We report an evaluation of the Abbott Enzymatic (Architect c4000), Roche Gen.3 HbA1c (Cobas c513) and Tosoh G11 using different quality targets. The effect of hemoglobin variants, other potential interferences and the performance in comparison to both the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and the National Glycohemoglobin Standardization Program (NGSP) reference systems was assessed using certified evaluation protocols. Each of the evaluated HbA1c methods had CVs <3% in SI units and <2% in NGSP units at 46 mmol/mol (6.4%) and 72 mmol/mol (8.7%) and passed the NGSP criteria when compared with six secondary reference measurement procedures (SRMPs). Sigma was 8.6 for Abbott Enzymatic, 3.3 for Roche Cobas c513 and 6.9 for Tosoh G11. No clinically significant interference was detected for the common Hb variants for the three methods. All three methods performed well and are suitable for clinical application in the analysis of HbA1c. Partly based on the result of this study, the Abbott Enzymatic method on the Architect c4000 and the Roche Gen.3 HbA1c on the Cobas c513 are now official, certified IFCC and NGSP SRMPs in the IFCC and NGSP networks. Sigma metrics quality criteria presented in a graph distinguish between good and excellent performance.

  1. Research on Holographic Evaluation of Service Quality in Power Data Network

    NASA Astrophysics Data System (ADS)

    Wei, Chen; Jing, Tao; Ji, Yutong

    2018-01-01

    With the rapid development of power data network, the continuous development of the Power data application service system, more and more service systems are being put into operation. Following this, the higher requirements for network quality and service quality are raised, in the actual process for the network operation and maintenance. This paper describes the electricity network and data network services status. A holographic assessment model was presented to achieve a comprehensive intelligence assessment on the power data network and quality of service in the operation and maintenance on the power data network. This evaluation method avoids the problems caused by traditional means which performs a single assessment of network performance quality. This intelligent Evaluation method can improve the efficiency of network operation and maintenance guarantee the quality of real-time service in the power data network..

  2. Evaluation of ride quality prediction methods for operational military helicopters

    NASA Technical Reports Server (NTRS)

    Leatherwood, J. D.; Clevenson, S. A.; Hollenbaugh, D. D.

    1984-01-01

    The results of a simulator study conducted to compare and validate various ride quality prediction methods for use in assessing passenger/crew ride comfort within helicopters are presented. Included are results quantifying 35 helicopter pilots' discomfort responses to helicopter interior noise and vibration typical of routine flights, assessment of various ride quality metrics including the NASA ride comfort model, and examination of possible criteria approaches. Results of the study indicated that crew discomfort results from a complex interaction between vibration and interior noise. Overall measures such as weighted or unweighted root-mean-square acceleration level and A-weighted noise level were not good predictors of discomfort. Accurate prediction required a metric incorporating the interactive effects of both noise and vibration. The best metric for predicting crew comfort to the combined noise and vibration environment was the NASA discomfort index.

  3. A new method to evaluate the quality of single crystal Cu by an X-ray diffraction butterfly pattern method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu Zhenming; Guo Zhenqi; Li Jianguo

    2004-12-15

    A new method for the evaluation of the quality of an Ohno continuous cast (OCC) Cu single crystal by X-ray diffraction (XRD) butterfly pattern was brought forward. Experimental results show that the growth direction of single crystal Cu is inclined from both sides of the single crystal Cu rod to the axis and is axially symmetric. The degree of deviation from the [100] orientation from the crystal axis is less than 5 deg. with a casting speed 10-40 mm/min. The orientation of single crystal Cu does not have a fixed direction but is in a regular range. Moreover, the orientationmore » of stray grains in the single crystal Cu is random from continuous casting.« less

  4. Methodology for Evaluating Quality and Reusability of Learning Objects

    ERIC Educational Resources Information Center

    Kurilovas, Eugenijus; Bireniene, Virginija; Serikoviene, Silvija

    2011-01-01

    The aim of the paper is to present the scientific model and several methods for the expert evaluation of quality of learning objects (LOs) paying especial attention to LOs reusability level. The activities of eQNet Quality Network for a European Learning Resource Exchange (LRE) aimed to improve reusability of LOs of European Schoolnet's LRE…

  5. Process service quality evaluation based on Dempster-Shafer theory and support vector machine.

    PubMed

    Pei, Feng-Que; Li, Dong-Bo; Tong, Yi-Fei; He, Fei

    2017-01-01

    Human involvement influences traditional service quality evaluations, which triggers an evaluation's low accuracy, poor reliability and less impressive predictability. This paper proposes a method by employing a support vector machine (SVM) and Dempster-Shafer evidence theory to evaluate the service quality of a production process by handling a high number of input features with a low sampling data set, which is called SVMs-DS. Features that can affect production quality are extracted by a large number of sensors. Preprocessing steps such as feature simplification and normalization are reduced. Based on three individual SVM models, the basic probability assignments (BPAs) are constructed, which can help the evaluation in a qualitative and quantitative way. The process service quality evaluation results are validated by the Dempster rules; the decision threshold to resolve conflicting results is generated from three SVM models. A case study is presented to demonstrate the effectiveness of the SVMs-DS method.

  6. Development and evaluation of a quality score for abstracts

    PubMed Central

    Timmer, Antje; Sutherland, Lloyd R; Hilsden, Robert J

    2003-01-01

    Background The evaluation of abstracts for scientific meetings has been shown to suffer from poor inter observer reliability. A measure was developed to assess the formal quality of abstract submissions in a standardized way. Methods Item selection was based on scoring systems for full reports, taking into account published guidelines for structured abstracts. Interrater agreement was examined using a random sample of submissions to the American Gastroenterological Association, stratified for research type (n = 100, 1992–1995). For construct validity, the association of formal quality with acceptance for presentation was examined. A questionnaire to expert reviewers evaluated sensibility items, such as ease of use and comprehensiveness. Results The index comprised 19 items. The summary quality scores showed good interrater agreement (intra class coefficient 0.60 – 0.81). Good abstract quality was associated with abstract acceptance for presentation at the meeting. The instrument was found to be acceptable by expert reviewers. Conclusion A quality index was developed for the evaluation of scientific meeting abstracts which was shown to be reliable, valid and useful. PMID:12581457

  7. Aggregative Learning Method and Its Application for Communication Quality Evaluation

    NASA Astrophysics Data System (ADS)

    Akhmetov, Dauren F.; Kotaki, Minoru

    2007-12-01

    In this paper, so-called Aggregative Learning Method (ALM) is proposed to improve and simplify the learning and classification abilities of different data processing systems. It provides a universal basis for design and analysis of mathematical models of wide class. A procedure was elaborated for time series model reconstruction and analysis for linear and nonlinear cases. Data approximation accuracy (during learning phase) and data classification quality (during recall phase) are estimated from introduced statistic parameters. The validity and efficiency of the proposed approach have been demonstrated through its application for monitoring of wireless communication quality, namely, for Fixed Wireless Access (FWA) system. Low memory and computation resources were shown to be needed for the procedure realization, especially for data classification (recall) stage. Characterized with high computational efficiency and simple decision making procedure, the derived approaches can be useful for simple and reliable real-time surveillance and control system design.

  8. Comparison of case note review methods for evaluating quality and safety in health care.

    PubMed

    Hutchinson, A; Coster, J E; Cooper, K L; McIntosh, A; Walters, S J; Bath, P A; Pearson, M; Young, T A; Rantell, K; Campbell, M J; Ratcliffe, J

    2010-02-01

    To determine which of two methods of case note review--holistic (implicit) and criterion-based (explicit)--provides the most useful and reliable information for quality and safety of care, and the level of agreement within and between groups of health-care professionals when they use the two methods to review the same record. To explore the process-outcome relationship between holistic and criterion-based quality-of-care measures and hospital-level outcome indicators. Case notes of patients at randomly selected hospitals in England. In the first part of the study, retrospective multiple reviews of 684 case notes were undertaken at nine acute hospitals using both holistic and criterion-based review methods. Quality-of-care measures included evidence-based review criteria and a quality-of-care rating scale. Textual commentary on the quality of care was provided as a component of holistic review. Review teams comprised combinations of: doctors (n = 16), specialist nurses (n = 10) and clinically trained audit staff (n = 3) and non-clinical audit staff (n = 9). In the second part of the study, process (quality and safety) of care data were collected from the case notes of 1565 people with either chronic obstructive pulmonary disease (COPD) or heart failure in 20 hospitals. Doctors collected criterion-based data from case notes and used implicit review methods to derive textual comments on the quality of care provided and score the care overall. Data were analysed for intrarater consistency, inter-rater reliability between pairs of staff using intraclass correlation coefficients (ICCs) and completeness of criterion data capture, and comparisons were made within and between staff groups and between review methods. To explore the process-outcome relationship, a range of publicly available health-care indicator data were used as proxy outcomes in a multilevel analysis. Overall, 1473 holistic and 1389 criterion-based reviews were undertaken in the first part of the study

  9. [Grades evaluation of Phellodendri chinensis cortex pieces based on quality constant].

    PubMed

    Deng, Zhe; Jiao, Meng-Jiao; Zhang, Jun; Zhang, Qing; Cui, Wen-Jin; Shen, Li; Cheng, Jin-Tang; Liu, An

    2017-09-01

    Quality constant is a comprehensive grades evaluation method for traditional Chinese medicine decoction pieces, which is better but based on traditional way. In this paper, a new grading mode for Phellodendri chinensis pieces was established based on quality constant evaluation method. The results showed that the range of relative quality constant for 15 batches of different samples was from 0.41 to 0.96. As customary, if these samples were divided into three grades: the relative quality constant shall be ≥0.77 for first grade; <0.77 but ≥0.48 for the second grade; and <0.48 for the third grade. This research indicated that the quality constant mode can be used to effectively grade the P. chinensis pieces in a scientific, reasonable, objective and specific way. Simultaneously, it provided a beneficial reference for grading cortex herbal pieces or medicines. Copyright© by the Chinese Pharmaceutical Association.

  10. Designing a Score-Based Method for the Evaluation of the Nutritional Quality of the Gluten-Free Bakery Products and their Gluten-Containing Counterparts.

    PubMed

    Morreale, Federico; Angelino, Donato; Pellegrini, Nicoletta

    2018-04-25

    Gluten-free (GF) products are consumed both by individuals with celiac disease and by an increasing number of people with no specific medical needs. Although the technological quality of GF products has been recently improved, their nutritional quality is still scarcely addressed. Moreover, the few published studies report conflicting results, mostly because the information from product nutrition facts is the only considered factor. The aim of the present study was to develop a score-based method for the nutritional evaluation of 134 packaged Italian GF bakery products and to compare it with that of 162 matched gluten-containing (GC) food items. The score included the information from the nutrition facts and the presence/absence of some nutritionally relevant components in the ingredients list. Results indicated an overall low nutritional quality of the considered GF bakery products. Additionally, with the sole exception of GF bread substitutes, there was no difference in nutritional quality between GF and equivalent GC bakery products. Future research and development of GF bakery products may take advantage of this scoring method, as it may represent an easy approach to evaluate their nutritional quality. The present findings do not justify the consumption of packaged GF bakery products by people without any specific medical needs.

  11. From quality markers to data mining and intelligence assessment: A smart quality-evaluation strategy for traditional Chinese medicine based on quality markers.

    PubMed

    Bai, Gang; Zhang, Tiejun; Hou, Yuanyuan; Ding, Guoyu; Jiang, Min; Luo, Guoan

    2018-05-15

    The quality of traditional Chinese medicine (TCM) forms the foundation of its clinical efficacy. The standardization of TCM is the most important task of TCM modernization. In recent years, there has been great progress in the quality control of TCM. However, there are still many issues related to the current quality standards, and it is difficult to objectively evaluate and effectively control the quality of TCM. To face these challenge, we summarized the current quality marker (Q-marker) research based on its characteristics and benefits, and proposed a reasonable and intelligentized quality evaluation strategy for the development and application of Q-markers. Ultra-performance liquid chromatography-quadrupole/time-of-flight with partial least squares-discriminant analysis was suggested to screen the chemical markers from Chinese medicinal materials (CMM), and a bioactive-guided evaluation method was used to select the Q-markers. Near-infrared spectroscopy (NIRS), based on the distinctive wavenumber zones or points from the Q-markers, was developed for its determination. Then, artificial intelligence algorithms were used to clarify the complex relationship between the Q-markers and their integral functions. Internet and mobile communication technology helped us to perform remote analysis and determine the information feedback of test samples. The quality control research, evaluation, standard establishment and quality control of TCM must be based on the systematic analysis of Q-markers to study and describe the material basis of TCM efficacy, define the chemical markers in the plant body, and understand the process of herb drug acquisition, change and transmission laws affecting metabolism and exposure. Based on the advantages of chemometrics, new sensor technologies, including infrared spectroscopy, hyperspectral imaging, chemical imaging, electronic nose and electronic tongue, have become increasingly important in the quality evaluation of CMM. Inspired by the

  12. Applications of hyperspectral imaging in chicken meat safety and quality detection and evaluation: a review.

    PubMed

    Xiong, Zhenjie; Xie, Anguo; Sun, Da-Wen; Zeng, Xin-An; Liu, Dan

    2015-01-01

    Currently, the issue of food safety and quality is a great public concern. In order to satisfy the demands of consumers and obtain superior food qualities, non-destructive and fast methods are required for quality evaluation. As one of these methods, hyperspectral imaging (HSI) technique has emerged as a smart and promising analytical tool for quality evaluation purposes and has attracted much interest in non-destructive analysis of different food products. With the main advantage of combining both spectroscopy technique and imaging technique, HSI technique shows a convinced attitude to detect and evaluate chicken meat quality objectively. Moreover, developing a quality evaluation system based on HSI technology would bring economic benefits to the chicken meat industry. Therefore, in recent years, many studies have been conducted on using HSI technology for the safety and quality detection and evaluation of chicken meat. The aim of this review is thus to give a detailed overview about HSI and focus on the recently developed methods exerted in HSI technology developed for microbiological spoilage detection and quality classification of chicken meat. Moreover, the usefulness of HSI technique for detecting fecal contamination and bone fragments of chicken carcasses are presented. Finally, some viewpoints on its future research and applicability in the modern poultry industry are proposed.

  13. Evaluating supplier quality performance using fuzzy analytical hierarchy process

    NASA Astrophysics Data System (ADS)

    Ahmad, Nazihah; Kasim, Maznah Mat; Rajoo, Shanmugam Sundram Kalimuthu

    2014-12-01

    Evaluating supplier quality performance is vital in ensuring continuous supply chain improvement, reducing the operational costs and risks towards meeting customer's expectation. This paper aims to illustrate an application of Fuzzy Analytical Hierarchy Process to prioritize the evaluation criteria in a context of automotive manufacturing in Malaysia. Five main criteria were identified which were quality, cost, delivery, customer serviceand technology support. These criteria had been arranged into hierarchical structure and evaluated by an expert. The relative importance of each criteria was determined by using linguistic variables which were represented as triangular fuzzy numbers. The Center of Gravity defuzzification method was used to convert the fuzzy evaluations into their corresponding crisps values. Such fuzzy evaluation can be used as a systematic tool to overcome the uncertainty evaluation of suppliers' performance which usually associated with human being subjective judgments.

  14. Evaluation method based on the image correlation for laser jamming image

    NASA Astrophysics Data System (ADS)

    Che, Jinxi; Li, Zhongmin; Gao, Bo

    2013-09-01

    The jamming effectiveness evaluation of infrared imaging system is an important part of electro-optical countermeasure. The infrared imaging devices in the military are widely used in the searching, tracking and guidance and so many other fields. At the same time, with the continuous development of laser technology, research of laser interference and damage effect developed continuously, laser has been used to disturbing the infrared imaging device. Therefore, the effect evaluation of the infrared imaging system by laser has become a meaningful problem to be solved. The information that the infrared imaging system ultimately present to the user is an image, so the evaluation on jamming effect can be made from the point of assessment of image quality. The image contains two aspects of the information, the light amplitude and light phase, so the image correlation can accurately perform the difference between the original image and disturbed image. In the paper, the evaluation method of digital image correlation, the assessment method of image quality based on Fourier transform, the estimate method of image quality based on error statistic and the evaluation method of based on peak signal noise ratio are analysed. In addition, the advantages and disadvantages of these methods are analysed. Moreover, the infrared disturbing images of the experiment result, in which the thermal infrared imager was interfered by laser, were analysed by using these methods. The results show that the methods can better reflect the jamming effects of the infrared imaging system by laser. Furthermore, there is good consistence between evaluation results by using the methods and the results of subjective visual evaluation. And it also provides well repeatability and convenient quantitative analysis. The feasibility of the methods to evaluate the jamming effect was proved. It has some extent reference value for the studying and developing on electro-optical countermeasures equipments and

  15. Using Economic Evaluation to Illustrate Value of Care for Improving Patient Safety and Quality: Choosing the Right Method.

    PubMed

    Padula, William V; Lee, Ken K H; Pronovost, Peter J

    2017-08-03

    To scale and sustain successful quality improvement (QI) interventions, it is recommended for health system leaders to calculate the economic and financial sustainability of the intervention. Many methods of economic evaluation exist, and the type of method depends on the audience: providers, researchers, and hospital executives. This is a primer to introduce cost-effectiveness analysis, budget impact analysis, and return on investment calculation as 3 distinct methods for each stakeholder needing a measurement of the value of QI at the health system level. Using cases for the QI of hospital-acquired condition rates (e.g., pressure injuries), this primer proceeds stepwise through each method beginning from the same starting point of constructing a model so that the repetition of steps is minimized and thereby capturing the attention of all intended audiences.

  16. Evaluating the Impact of Library Instruction Methods on the Quality of Student Research.

    ERIC Educational Resources Information Center

    Ackerson, Linda G.; Young, Virgina E.

    1994-01-01

    A three-year study at the University of Alabama compared a traditional lecture method for teaching library research skills with a course-integrated, computer-enhanced approach by assessing each method's impact on the quality of bibliographies from engineering students' term papers. In four of the five semesters, no significant differences were…

  17. A method for evaluating image quality of monochrome and color displays based on luminance by use of a commercially available color digital camera

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tokurei, Shogo, E-mail: shogo.tokurei@gmail.com, E-mail: junjim@med.kyushu-u.ac.jp; Morishita, Junji, E-mail: shogo.tokurei@gmail.com, E-mail: junjim@med.kyushu-u.ac.jp

    Purpose: The aim of this study is to propose a method for the quantitative evaluation of image quality of both monochrome and color liquid-crystal displays (LCDs) using a commercially available color digital camera. Methods: The intensities of the unprocessed red (R), green (G), and blue (B) signals of a camera vary depending on the spectral sensitivity of the image sensor used in the camera. For consistent evaluation of image quality for both monochrome and color LCDs, the unprocessed RGB signals of the camera were converted into gray scale signals that corresponded to the luminance of the LCD. Gray scale signalsmore » for the monochrome LCD were evaluated by using only the green channel signals of the camera. For the color LCD, the RGB signals of the camera were converted into gray scale signals by employing weighting factors (WFs) for each RGB channel. A line image displayed on the color LCD was simulated on the monochrome LCD by using a software application for subpixel driving in order to verify the WF-based conversion method. Furthermore, the results obtained by different types of commercially available color cameras and a photometric camera were compared to examine the consistency of the authors’ method. Finally, image quality for both the monochrome and color LCDs was assessed by measuring modulation transfer functions (MTFs) and Wiener spectra (WS). Results: The authors’ results demonstrated that the proposed method for calibrating the spectral sensitivity of the camera resulted in a consistent and reliable evaluation of the luminance of monochrome and color LCDs. The MTFs and WS showed different characteristics for the two LCD types owing to difference in the subpixel structure. The MTF in the vertical direction of the color LCD was superior to that of the monochrome LCD, although the WS in the vertical direction of the color LCD was inferior to that of the monochrome LCD as a result of luminance fluctuations in RGB subpixels. Conclusions: The

  18. Extraction of GBH Film Medicine and Influence on Quality Evaluation of The Film

    NASA Astrophysics Data System (ADS)

    Ji, Y. B.; Lu, L.; Ru, X.; Guo, S. Z.; Qiao, A. N.; Wang, S. W.

    2017-12-01

    To know the extraction effects of GBH film medicine and the influence on film quality evaluation. Ultrasonic extraction and reflux extraction were used to extract the two methods with the traditional water decocting method to contrast. They were used to determining the content of total flavonoids. The same method was used to separate the root of the main medicinal herbs and the decoction of the water decoction of the other drug powder. They were used to determine the content of total flavonoids. The effect of extraction method on the preparation of membrane was investigated. The membrane preparation, evaluation and flexibility, respectively, film-forming property, smoothness and disintegration time are used to evaluating separately the effect of extraction method. The results showed that the extraction effect of 70% ethanol concentration of total flavonoids. The best extraction method had no effect on the film quality initial evaluation. This experiment provides a method for membrane extraction agent, has a certain practical significance.

  19. Study on a pattern classification method of soil quality based on simplified learning sample dataset

    USGS Publications Warehouse

    Zhang, Jiahua; Liu, S.; Hu, Y.; Tian, Y.

    2011-01-01

    Based on the massive soil information in current soil quality grade evaluation, this paper constructed an intelligent classification approach of soil quality grade depending on classical sampling techniques and disordered multiclassification Logistic regression model. As a case study to determine the learning sample capacity under certain confidence level and estimation accuracy, and use c-means algorithm to automatically extract the simplified learning sample dataset from the cultivated soil quality grade evaluation database for the study area, Long chuan county in Guangdong province, a disordered Logistic classifier model was then built and the calculation analysis steps of soil quality grade intelligent classification were given. The result indicated that the soil quality grade can be effectively learned and predicted by the extracted simplified dataset through this method, which changed the traditional method for soil quality grade evaluation. ?? 2011 IEEE.

  20. A shape-based quality evaluation and reconstruction method for electrical impedance tomography.

    PubMed

    Antink, Christoph Hoog; Pikkemaat, Robert; Malmivuo, Jaakko; Leonhardt, Steffen

    2015-06-01

    Linear methods of reconstruction play an important role in medical electrical impedance tomography (EIT) and there is a wide variety of algorithms based on several assumptions. With the Graz consensus reconstruction algorithm for EIT (GREIT), a novel linear reconstruction algorithm as well as a standardized framework for evaluating and comparing methods of reconstruction were introduced that found widespread acceptance in the community. In this paper, we propose a two-sided extension of this concept by first introducing a novel method of evaluation. Instead of being based on point-shaped resistivity distributions, we use 2759 pairs of real lung shapes for evaluation that were automatically segmented from human CT data. Necessarily, the figures of merit defined in GREIT were adjusted. Second, a linear method of reconstruction that uses orthonormal eigenimages as training data and a tunable desired point spread function are proposed. Using our novel method of evaluation, this approach is compared to the classical point-shaped approach. Results show that most figures of merit improve with the use of eigenimages as training data. Moreover, the possibility of tuning the reconstruction by modifying the desired point spread function is shown. Finally, the reconstruction of real EIT data shows that higher contrasts and fewer artifacts can be achieved in ventilation- and perfusion-related images.

  1. Quality dimensions in health evaluation: manager's conceptions.

    PubMed

    Bosi, Maria Lúcia Magalhães; Pontes, Ricardo José Soares; Vasconcelos, Suziana Martins de

    2010-04-01

    To understand manager's perceptions and experiences in regards to qualitative evaluations in basic health care. A qualitative study, based on the critical interpretive approach, was performed in 2006, in the city of Fortaleza, Northeastern Brazil. The sample consisted of the group responsible for planning basic health care at the state level. In order to obtain the empirical data, the focus group technique was utilized. Two central themes emerged concerning the perceptions about quality and the dimensions of quality employed in health evaluations, which were revealed in distinct ways. The concepts of quality evaluation and qualitative evaluation did not appear clearly understood, confusing qualitative evaluation with formal quality evaluations. Likewise, the inherent multidimensionality of quality was not recognized. Despite the criticism expressed by the participants regarding the improper quantification of certain dimensions, the necessary technical skills and understanding were not observed for the approach to include the distinct dimensions of quality in the evaluation process. The conceptions of managers responsible for the planning of basic health care at the state level revealed an important disassociation from the premises of qualitative evaluation, especially those evaluations oriented by the fourth generation approach. Therefore, the model adopted by these actors for the evaluation of program and service quality did not consider their multidimensionality.

  2. Designing and evaluating the MULTICOM protein local and global model quality prediction methods in the CASP10 experiment

    PubMed Central

    2014-01-01

    Background Protein model quality assessment is an essential component of generating and using protein structural models. During the Tenth Critical Assessment of Techniques for Protein Structure Prediction (CASP10), we developed and tested four automated methods (MULTICOM-REFINE, MULTICOM-CLUSTER, MULTICOM-NOVEL, and MULTICOM-CONSTRUCT) that predicted both local and global quality of protein structural models. Results MULTICOM-REFINE was a clustering approach that used the average pairwise structural similarity between models to measure the global quality and the average Euclidean distance between a model and several top ranked models to measure the local quality. MULTICOM-CLUSTER and MULTICOM-NOVEL were two new support vector machine-based methods of predicting both the local and global quality of a single protein model. MULTICOM-CONSTRUCT was a new weighted pairwise model comparison (clustering) method that used the weighted average similarity between models in a pool to measure the global model quality. Our experiments showed that the pairwise model assessment methods worked better when a large portion of models in the pool were of good quality, whereas single-model quality assessment methods performed better on some hard targets when only a small portion of models in the pool were of reasonable quality. Conclusions Since digging out a few good models from a large pool of low-quality models is a major challenge in protein structure prediction, single model quality assessment methods appear to be poised to make important contributions to protein structure modeling. The other interesting finding was that single-model quality assessment scores could be used to weight the models by the consensus pairwise model comparison method to improve its accuracy. PMID:24731387

  3. Designing and evaluating the MULTICOM protein local and global model quality prediction methods in the CASP10 experiment.

    PubMed

    Cao, Renzhi; Wang, Zheng; Cheng, Jianlin

    2014-04-15

    Protein model quality assessment is an essential component of generating and using protein structural models. During the Tenth Critical Assessment of Techniques for Protein Structure Prediction (CASP10), we developed and tested four automated methods (MULTICOM-REFINE, MULTICOM-CLUSTER, MULTICOM-NOVEL, and MULTICOM-CONSTRUCT) that predicted both local and global quality of protein structural models. MULTICOM-REFINE was a clustering approach that used the average pairwise structural similarity between models to measure the global quality and the average Euclidean distance between a model and several top ranked models to measure the local quality. MULTICOM-CLUSTER and MULTICOM-NOVEL were two new support vector machine-based methods of predicting both the local and global quality of a single protein model. MULTICOM-CONSTRUCT was a new weighted pairwise model comparison (clustering) method that used the weighted average similarity between models in a pool to measure the global model quality. Our experiments showed that the pairwise model assessment methods worked better when a large portion of models in the pool were of good quality, whereas single-model quality assessment methods performed better on some hard targets when only a small portion of models in the pool were of reasonable quality. Since digging out a few good models from a large pool of low-quality models is a major challenge in protein structure prediction, single model quality assessment methods appear to be poised to make important contributions to protein structure modeling. The other interesting finding was that single-model quality assessment scores could be used to weight the models by the consensus pairwise model comparison method to improve its accuracy.

  4. A solution quality assessment method for swarm intelligence optimization algorithms.

    PubMed

    Zhang, Zhaojun; Wang, Gai-Ge; Zou, Kuansheng; Zhang, Jianhua

    2014-01-01

    Nowadays, swarm intelligence optimization has become an important optimization tool and wildly used in many fields of application. In contrast to many successful applications, the theoretical foundation is rather weak. Therefore, there are still many problems to be solved. One problem is how to quantify the performance of algorithm in finite time, that is, how to evaluate the solution quality got by algorithm for practical problems. It greatly limits the application in practical problems. A solution quality assessment method for intelligent optimization is proposed in this paper. It is an experimental analysis method based on the analysis of search space and characteristic of algorithm itself. Instead of "value performance," the "ordinal performance" is used as evaluation criteria in this method. The feasible solutions were clustered according to distance to divide solution samples into several parts. Then, solution space and "good enough" set can be decomposed based on the clustering results. Last, using relative knowledge of statistics, the evaluation result can be got. To validate the proposed method, some intelligent algorithms such as ant colony optimization (ACO), particle swarm optimization (PSO), and artificial fish swarm algorithm (AFS) were taken to solve traveling salesman problem. Computational results indicate the feasibility of proposed method.

  5. Optimization of Selective Laser Melting by Evaluation Method of Multiple Quality Characteristics

    NASA Astrophysics Data System (ADS)

    Khaimovich, A. I.; Stepanenko, I. S.; Smelov, V. G.

    2018-01-01

    Article describes the adoption of the Taguchi method in selective laser melting process of sector of combustion chamber by numerical and natural experiments for achieving minimum temperature deformation. The aim was to produce a quality part with minimum amount of numeric experiments. For the study, the following optimization parameters (independent factors) were chosen: the laser beam power and velocity; two factors for compensating the effect of the residual thermal stresses: the scale factor of the preliminary correction of the part geometry and the number of additional reinforcing elements. We used an orthogonal plan of 9 experiments with a factor variation at three levels (L9). As quality criterias, the values of distortions for 9 zones of the combustion chamber and the maximum strength of the material of the chamber were chosen. Since the quality parameters are multidirectional, a grey relational analysis was used to solve the optimization problem for multiple quality parameters. As a result, according to the parameters obtained, the combustion chamber segments of the gas turbine engine were manufactured.

  6. Measuring quality of care: considering conceptual approaches to quality indicator development and evaluation.

    PubMed

    Stelfox, Henry T; Straus, Sharon E

    2013-12-01

    In this article, we describe one approach for developing and evaluating quality indicators. We focus on describing different conceptual approaches to quality indicator development, review one approach for developing quality indicators, outline how to evaluate quality indicators once developed, and discuss quality indicator maintenance. The key steps for developing quality indicators include specifying a clear goal for the indicators; using methodologies to incorporate evidence, expertise, and patient perspectives; and considering contextual factors and logistics of implementation. The Strategic Framework Board and the National Quality Measure Clearinghouse have developed criteria for evaluating quality indicators that complement traditional psychometric evaluations. Optimal strategies for quality indicator maintenance and dissemination have not been determined, but experiences with clinical guideline maintenance may be informative. For quality indicators to effectively guide quality improvement efforts, they must be developed, evaluated, maintained, and implemented using rigorous evidence-informed practices. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. [Grades evaluation of Scutellariae Radix slices based on quality constant].

    PubMed

    Deng, Zhe; Zhang, Jun; Jiao, Meng-Jiao; Zhong, Wen; Cui, Wen-Jin; Cheng, Jin-Tang; Chen, Sha; Wang, Yue-Sheng; Liu, An

    2017-05-01

    By measuring the morphological indexes and the marker components content of 22 batches of Scutellariae Radix slices as well as calculating the quality constant, this research was aimed to establish a new method of evaluating the specifications and grades of Scutellariae Radix slices. The quality constants of these samples were in the range of 0.04-0.49, which can be divided into several grades based on the real requirement. If they were divided into three grades, the quality constant was ≥0.39 for the first grade, <0.39 but ≥0.24 for the second grade, and <0.24 for the third grade. This work indicated that the quality constants characterizing both apparent parameters and intrinsic quality can be used as a comprehensive evaluation index to classify the grades of traditional Chinese medicine quantitatively, clearly and objectively. The research results in this paper would provide new ideas and references for evaluating the specifications and grades of traditional Chinese medicines. Copyright© by the Chinese Pharmaceutical Association.

  8. Clinical image quality evaluation for panoramic radiography in Korean dental clinics

    PubMed Central

    Choi, Bo-Ram; Choi, Da-Hye; Huh, Kyung-Hoe; Yi, Won-Jin; Heo, Min-Suk; Choi, Soon-Chul; Bae, Kwang-Hak

    2012-01-01

    Purpose The purpose of this study was to investigate the level of clinical image quality of panoramic radiographs and to analyze the parameters that influence the overall image quality. Materials and Methods Korean dental clinics were asked to provide three randomly selected panoramic radiographs. An oral and maxillofacial radiology specialist evaluated those images using our self-developed Clinical Image Quality Evaluation Chart. Three evaluators classified the overall image quality of the panoramic radiographs and evaluated the causes of imaging errors. Results A total of 297 panoramic radiographs were collected from 99 dental hospitals and clinics. The mean of the scores according to the Clinical Image Quality Evaluation Chart was 79.9. In the classification of the overall image quality, 17 images were deemed 'optimal for obtaining diagnostic information,' 153 were 'adequate for diagnosis,' 109 were 'poor but diagnosable,' and nine were 'unrecognizable and too poor for diagnosis'. The results of the analysis of the causes of the errors in all the images are as follows: 139 errors in the positioning, 135 in the processing, 50 from the radiographic unit, and 13 due to anatomic abnormality. Conclusion Panoramic radiographs taken at local dental clinics generally have a normal or higher-level image quality. Principal factors affecting image quality were positioning of the patient and image density, sharpness, and contrast. Therefore, when images are taken, the patient position should be adjusted with great care. Also, standardizing objective criteria of image density, sharpness, and contrast is required to evaluate image quality effectively. PMID:23071969

  9. Quality evaluation of Hypericum ascyron extract by two-dimensional high-performance liquid chromatography coupled with the colorimetric 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide method.

    PubMed

    Li, Xiu-Mei; Luo, Xue-Gang; Zhang, Chao-Zheng; Wang, Nan; Zhang, Tong-Cun

    2015-02-01

    In this paper, a heart-cutting two-dimensional high-performance liquid chromatography coupled with the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) method was established for controlling the quality of different batches of Hypericum ascyron extract for the first time. In comparison with the common one-dimensional fingerprint, the second-dimensional fingerprint compiled additional spectral data and was hence more informative. The quality of H. ascyron extract was further evaluated by similarity measures and the same results were achieved, the correlation coefficients of the similarity of ten batches of H. ascyron extract were >0.99. Furthermore, we also evaluated the quality of the ten batches of H. ascyron extract by antibacterial activity. The result demonstrated that the quality of the ten batches of H. ascyron extract was not significantly different by MTT. Finally, we demonstrated that the second-dimensional fingerprint coupled with the MTT method was a more powerful tool to characterize the quality of samples of batch to batch. Therefore the proposed method could be used to comprehensively conduct the quality control of traditional Chinese medicines. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Reliable clarity automatic-evaluation method for optical remote sensing images

    NASA Astrophysics Data System (ADS)

    Qin, Bangyong; Shang, Ren; Li, Shengyang; Hei, Baoqin; Liu, Zhiwen

    2015-10-01

    Image clarity, which reflects the sharpness degree at the edge of objects in images, is an important quality evaluate index for optical remote sensing images. Scholars at home and abroad have done a lot of work on estimation of image clarity. At present, common clarity-estimation methods for digital images mainly include frequency-domain function methods, statistical parametric methods, gradient function methods and edge acutance methods. Frequency-domain function method is an accurate clarity-measure approach. However, its calculation process is complicate and cannot be carried out automatically. Statistical parametric methods and gradient function methods are both sensitive to clarity of images, while their results are easy to be affected by the complex degree of images. Edge acutance method is an effective approach for clarity estimate, while it needs picking out the edges manually. Due to the limits in accuracy, consistent or automation, these existing methods are not applicable to quality evaluation of optical remote sensing images. In this article, a new clarity-evaluation method, which is based on the principle of edge acutance algorithm, is proposed. In the new method, edge detection algorithm and gradient search algorithm are adopted to automatically search the object edges in images. Moreover, The calculation algorithm for edge sharpness has been improved. The new method has been tested with several groups of optical remote sensing images. Compared with the existing automatic evaluation methods, the new method perform better both in accuracy and consistency. Thus, the new method is an effective clarity evaluation method for optical remote sensing images.

  11. Process perspective on image quality evaluation

    NASA Astrophysics Data System (ADS)

    Leisti, Tuomas; Halonen, Raisa; Kokkonen, Anna; Weckman, Hanna; Mettänen, Marja; Lensu, Lasse; Ritala, Risto; Oittinen, Pirkko; Nyman, Göte

    2008-01-01

    The psychological complexity of multivariate image quality evaluation makes it difficult to develop general image quality metrics. Quality evaluation includes several mental processes and ignoring these processes and the use of a few test images can lead to biased results. By using a qualitative/quantitative (Interpretation Based Quality, IBQ) methodology, we examined the process of pair-wise comparison in a setting, where the quality of the images printed by laser printer on different paper grades was evaluated. Test image consisted of a picture of a table covered with several objects. Three other images were also used, photographs of a woman, cityscape and countryside. In addition to the pair-wise comparisons, observers (N=10) were interviewed about the subjective quality attributes they used in making their quality decisions. An examination of the individual pair-wise comparisons revealed serious inconsistencies in observers' evaluations on the test image content, but not on other contexts. The qualitative analysis showed that this inconsistency was due to the observers' focus of attention. The lack of easily recognizable context in the test image may have contributed to this inconsistency. To obtain reliable knowledge of the effect of image context or attention on subjective image quality, a qualitative methodology is needed.

  12. Organic food quality: a framework for concept, definition and evaluation from the European perspective.

    PubMed

    Kahl, Johannes; Baars, Ton; Bügel, Susanne; Busscher, Nicolaas; Huber, Machteld; Kusche, Daniel; Rembiałkowska, Ewa; Schmid, Otto; Seidel, Kathrin; Taupier-Letage, Bruno; Velimirov, Alberta; Załecka, Aneta

    2012-11-01

    Consumers buy organic food because they believe in the high quality of the product. Furthermore, the EU legal regulatory framework for organic food and farming defines high quality of the products as an important goal of production. A major challenge is the need to define food quality concepts and methods for determination. A background is described which allows embedding of the quality definitions as well as evaluation methods into a conceptual framework connected to the vision and mission of organic agriculture and food production. Organic food quality is defined through specific aspects and criteria. For evaluation each criterion has to be described by indicators. The determination of indicators should be through parameters, where parameters are described by methods. Conversely, the conceptual framework is described according to underlying principles and starting definitions are given, but further work has do be done on the detailed scientific description of the indicators. Furthermore, parameters have to be defined for the evaluation of suitability of these indicators for organic food production. Copyright © 2012 Society of Chemical Industry.

  13. Task-based image quality evaluation of iterative reconstruction methods for low dose CT using computer simulations

    NASA Astrophysics Data System (ADS)

    Xu, Jingyan; Fuld, Matthew K.; Fung, George S. K.; Tsui, Benjamin M. W.

    2015-04-01

    Iterative reconstruction (IR) methods for x-ray CT is a promising approach to improve image quality or reduce radiation dose to patients. The goal of this work was to use task based image quality measures and the channelized Hotelling observer (CHO) to evaluate both analytic and IR methods for clinical x-ray CT applications. We performed realistic computer simulations at five radiation dose levels, from a clinical reference low dose D0 to 25% D0. A fixed size and contrast lesion was inserted at different locations into the liver of the XCAT phantom to simulate a weak signal. The simulated data were reconstructed on a commercial CT scanner (SOMATOM Definition Flash; Siemens, Forchheim, Germany) using the vendor-provided analytic (WFBP) and IR (SAFIRE) methods. The reconstructed images were analyzed by CHOs with both rotationally symmetric (RS) and rotationally oriented (RO) channels, and with different numbers of lesion locations (5, 10, and 20) in a signal known exactly (SKE), background known exactly but variable (BKEV) detection task. The area under the receiver operating characteristic curve (AUC) was used as a summary measure to compare the IR and analytic methods; the AUC was also used as the equal performance criterion to derive the potential dose reduction factor of IR. In general, there was a good agreement in the relative AUC values of different reconstruction methods using CHOs with RS and RO channels, although the CHO with RO channels achieved higher AUCs than RS channels. The improvement of IR over analytic methods depends on the dose level. The reference dose level D0 was based on a clinical low dose protocol, lower than the standard dose due to the use of IR methods. At 75% D0, the performance improvement was statistically significant (p < 0.05). The potential dose reduction factor also depended on the detection task. For the SKE/BKEV task involving 10 lesion locations, a dose reduction of at least 25% from D0 was achieved.

  14. Specific guidelines for assessing and improving the methodological quality of economic evaluations of newborn screening

    PubMed Central

    2012-01-01

    Background Economic evaluation of newborn screening poses specific methodological challenges. Amongst others, these challenges refer to the use of quality adjusted life years (QALYs) in newborns, and which costs and outcomes need to be considered in a full evaluation of newborn screening programmes. Because of the increasing scale and scope of such programmes, a better understanding of the methods of high-quality economic evaluations may be crucial for both producers/authors and consumers/reviewers of newborn screening-related economic evaluations. The aim of this study was therefore to develop specific guidelines designed to assess and improve the methodological quality of economic evaluations in newborn screening. Methods To develop the guidelines, existing guidelines for assessing the quality of economic evaluations were identified through a literature search, and were reviewed and consolidated using a deductive iterative approach. In a subsequent test phase, these guidelines were applied to various economic evaluations which acted as case studies. Results The guidelines for assessing and improving the methodological quality of economic evaluations in newborn screening are organized into 11 categories: “bibliographic details”, “study question and design”, “modelling”, “health outcomes”, “costs”, “discounting”, “presentation of results”, “sensitivity analyses”, “discussion”, “conclusions”, and “commentary”. Conclusions The application of the guidelines highlights important issues regarding newborn screening-related economic evaluations, and underscores the need for such issues to be afforded greater consideration in future economic evaluations. The variety in methodological quality detected by this study reveals the need for specific guidelines on the appropriate methods for conducting sound economic evaluations in newborn screening. PMID:22947299

  15. Evaluation of differences in quality of experience features for test stimuli of good-only and bad-only overall audiovisual quality

    NASA Astrophysics Data System (ADS)

    Strohmeier, Dominik; Kunze, Kristina; Göbel, Klemens; Liebetrau, Judith

    2013-01-01

    Assessing audiovisual Quality of Experience (QoE) is a key element to ensure quality acceptance of today's multimedia products. The use of descriptive evaluation methods allows evaluating QoE preferences and the underlying QoE features jointly. From our previous evaluations on QoE for mobile 3D video we found that mainly one dimension, video quality, dominates the descriptive models. Large variations of the visual video quality in the tests may be the reason for these findings. A new study was conducted to investigate whether test sets of low QoE are described differently than those of high audiovisual QoE. Reanalysis of previous data sets seems to confirm this hypothesis. Our new study consists of a pre-test and a main test, using the Descriptive Sorted Napping method. Data sets of good-only and bad-only video quality were evaluated separately. The results show that the perception of bad QoE is mainly determined one-dimensionally by visual artifacts, whereas the perception of good quality shows multiple dimensions. Here, mainly semantic-related features of the content and affective descriptors are used by the naïve test participants. The results show that, with increasing QoE of audiovisual systems, content semantics and users' a_ective involvement will become important for assessing QoE differences.

  16. A Quality Assessment Method Based on Common Distributed Targets for GF-3 Polarimetric SAR Data.

    PubMed

    Jiang, Sha; Qiu, Xiaolan; Han, Bing; Hu, Wenlong

    2018-03-07

    The GaoFen-3 (GF-3) satellite, launched on 10 August 2016, is the first C-band polarimetric synthetic aperture radar (PolSAR) satellite in China. The PolSAR system of GF-3 can collect a significant wealth of information for geophysical research and applications. Being used for related applications, GF-3 PolSAR images must be of good quality. It is necessary to evaluate the quality of polarimetric data and achieve the normalized quality monitoring during 8-year designed life of GF-3. In this study, a new quality assessment method of PolSAR data based on common distributed targets is proposed, and the performance of the method is analyzed by simulations and GF-3 experiments. We evaluate the quality of GF-3 PolSAR data by this method. Results suggest that GF-3 antenna is highly isolated, and the quality of calibrated data satisfies the requests of quantitative applications.

  17. Evaluation of image quality

    NASA Technical Reports Server (NTRS)

    Pavel, M.

    1993-01-01

    This presentation outlines in viewgraph format a general approach to the evaluation of display system quality for aviation applications. This approach is based on the assumption that it is possible to develop a model of the display which captures most of the significant properties of the display. The display characteristics should include spatial and temporal resolution, intensity quantizing effects, spatial sampling, delays, etc. The model must be sufficiently well specified to permit generation of stimuli that simulate the output of the display system. The first step in the evaluation of display quality is an analysis of the tasks to be performed using the display. Thus, for example, if a display is used by a pilot during a final approach, the aesthetic aspects of the display may be less relevant than its dynamic characteristics. The opposite task requirements may apply to imaging systems used for displaying navigation charts. Thus, display quality is defined with regard to one or more tasks. Given a set of relevant tasks, there are many ways to approach display evaluation. The range of evaluation approaches includes visual inspection, rapid evaluation, part-task simulation, and full mission simulation. The work described is focused on two complementary approaches to rapid evaluation. The first approach is based on a model of the human visual system. A model of the human visual system is used to predict the performance of the selected tasks. The model-based evaluation approach permits very rapid and inexpensive evaluation of various design decisions. The second rapid evaluation approach employs specifically designed critical tests that embody many important characteristics of actual tasks. These are used in situations where a validated model is not available. These rapid evaluation tests are being implemented in a workstation environment.

  18. Empirical evaluation of humpback whale telomere length estimates; quality control and factors causing variability in the singleplex and multiplex qPCR methods.

    PubMed

    Olsen, Morten Tange; Bérubé, Martine; Robbins, Jooke; Palsbøll, Per J

    2012-09-06

    Telomeres, the protective cap of chromosomes, have emerged as powerful markers of biological age and life history in model and non-model species. The qPCR method for telomere length estimation is one of the most common methods for telomere length estimation, but has received recent critique for being too error-prone and yielding unreliable results. This critique coincides with an increasing awareness of the potentials and limitations of the qPCR technique in general and the proposal of a general set of guidelines (MIQE) for standardization of experimental, analytical, and reporting steps of qPCR. In order to evaluate the utility of the qPCR method for telomere length estimation in non-model species, we carried out four different qPCR assays directed at humpback whale telomeres, and subsequently performed a rigorous quality control to evaluate the performance of each assay. Performance differed substantially among assays and only one assay was found useful for telomere length estimation in humpback whales. The most notable factors causing these inter-assay differences were primer design and choice of using singleplex or multiplex assays. Inferred amplification efficiencies differed by up to 40% depending on assay and quantification method, however this variation only affected telomere length estimates in the worst performing assays. Our results suggest that seemingly well performing qPCR assays may contain biases that will only be detected by extensive quality control. Moreover, we show that the qPCR method for telomere length estimation can be highly precise and accurate, and thus suitable for telomere measurement in non-model species, if effort is devoted to optimization at all experimental and analytical steps. We conclude by highlighting a set of quality controls which may serve for further standardization of the qPCR method for telomere length estimation, and discuss some of the factors that may cause variation in qPCR experiments.

  19. Computer image analysis in caryopses quality evaluation as exemplified by malting barley

    NASA Astrophysics Data System (ADS)

    Koszela, K.; Raba, B.; Zaborowicz, M.; Przybył, K.; Wojcieszak, D.; Czekała, W.; Ludwiczak, A.; Przybylak, A.; Boniecki, P.; Przybył, J.

    2015-07-01

    One of the purposes to employ modern technologies in agricultural and food industry is to increase the efficiency and automation of production processes, which helps improve productive effectiveness of business enterprises, thus making them more competitive. Nowadays, a challenge presents itself for this branch of economy, to produce agricultural and food products characterized by the best parameters in terms of quality, while maintaining optimum production and distribution costs of the processed biological material. Thus, several scientific centers seek to devise new and improved methods and technologies in this field, which will allow to meet the expectations. A new solution, under constant development, is to employ the so-called machine vision which is to replace human work in both quality and quantity evaluation processes. An indisputable advantage of employing the method is keeping the evaluation unbiased while improving its rate and, what is important, eliminating the fatigue factor of the expert. This paper elaborates on the topic of quality evaluation by marking the contamination in malting barley grains using computer image analysis and selected methods of artificial intelligence [4-5].

  20. Methods for examining data quality in healthcare integrated data repositories.

    PubMed

    Huser, Vojtech; Kahn, Michael G; Brown, Jeffrey S; Gouripeddi, Ramkiran

    2018-01-01

    This paper summarizes content of the workshop focused on data quality. The first speaker (VH) described data quality infrastructure and data quality evaluation methods currently in place within the Observational Data Science and Informatics (OHDSI) consortium. The speaker described in detail a data quality tool called Achilles Heel and latest development for extending this tool. Interim results of an ongoing Data Quality study within the OHDSI consortium were also presented. The second speaker (MK) described lessons learned and new data quality checks developed by the PEDsNet pediatric research network. The last two speakers (JB, RG) described tools developed by the Sentinel Initiative and University of Utah's service oriented framework. The workshop discussed at the end and throughout how data quality assessment can be advanced by combining best features of each network.

  1. Implementing hospital quality assurance policies in Iran: balancing licensing, annual evaluation, inspections and quality management systems.

    PubMed

    Aghaei Hashjin, Asgar; Delgoshaei, Bahram; Kringos, Dionne S; Tabibi, Seyed Jamaladin; Manouchehri, Jila; Klazinga, Niek S

    2015-01-01

    The purpose of this paper is to provide an overview of applied hospital quality assurance (QA) policies in Iran. A mixed method (quantitative data and qualitative document analysis) study was carried out between 1996 and 2010. The QA policy cycle forms a tight monitoring system to assure hospital quality by combining mandatory and voluntary methods in Iran. The licensing, annual evaluation and grading, and regulatory inspections statutorily implemented by the government as a national package to assure and improve hospital care quality, while implementing quality management systems (QMS) was voluntary for hospitals. The government's strong QA policy legislation role and support has been an important factor for successful QA implementation in Iran, though it may affected QA assessment independency and validity. Increased hospital evaluation independency and repositioning, updating standards, professional involvement and effectiveness studies could increase QA policy impact and maturity. The study highlights the current QA policy implementation cycle in Iranian hospitals. It provides a basis for further quality strategy development in Iranian hospitals and elsewhere. It also raises attention about finding the optimal balance between different QA policies, which is topical for many countries. This paper describes experiences when implementing a unique approach, combining mandatory and voluntary QA policies simultaneously in a developing country, which has invested considerably over time to improve hospital quality. The experiences with a mixed obligatory/voluntary approach and comprehensive policies in Iran may contain lessons for policy makers in developing and developed countries.

  2. Water quality assessment of Australian ports using water quality evaluation indices

    PubMed Central

    Jahan, Sayka

    2017-01-01

    Australian ports serve diverse and extensive activities, such as shipping, tourism and fisheries, which may all impact the quality of port water. In this work water quality monitoring at different ports using a range of water quality evaluation indices was applied to assess the port water quality. Seawater samples at 30 stations in the year 2016–2017 from six ports in NSW, Australia, namely Port Jackson, Botany, Kembla, Newcastle, Yamba and Eden, were investigated to determine the physicochemical and biological variables that affect the port water quality. The large datasets obtained were designed to determine the Water Quality Index, Heavy metal Evaluation Index, Contamination Index and newly developed Environmental Water Quality Index. The study revealed medium water quality index and high and medium heavy metal evaluation index at three of the study ports and high contamination index in almost all study ports. Low level dissolved oxygen and higher level of total dissolved solids, turbidity, fecal coliforms, copper, iron, lead, zinc, manganese, cadmium and cobalt are mainly responsible for the poor water qualities of the port areas. Good water quality at the background samples indicated that various port activities are the likely cause for poor water quality inside the port area. PMID:29244876

  3. Comparative analysis of water quality and toxicity assessment methods for urban highway runoff.

    PubMed

    Chen, Rui-Hong; Li, Fei-Peng; Zhang, Hai-Ping; Jiang, Yue; Mao, Ling-Chen; Wu, Ling-Ling; Chen, Ling

    2016-05-15

    In this study, comparative analyses of highway runoff samples obtained from seventeen storm events have been conducted between the traditional water quality assessment method and biotoxicity tests, using zebrafish (Danio rerio) embryos and luminous bacteria (Vibrio qinghaiensis. Q67) to provide useful information for ecotoxicity assessment of urban highway runoff. The study results showed that the Nemerow pollution index based on US EPA recommended Criteria Maximum Concentrations (CMC) (as traditional water quality assessment method) had no significant correlation with luminous bacteria acute toxicity test results, while significant correlation has been observed with two indicators of 72 hpf (hours post fertilization) hour hatching rate and 96 hpf abnormality rate from the toxicity test with zebrafish embryos. It is therefore concluded that the level of mixture toxicity of highway runoff could not be adequately measured by the Nemerow assessment method. Moreover, the key pollutants identified from the water quality assessment and from the biotoxicity evaluation were not consistent. For biotoxic effect evaluation of highway runoff, three indexes were found to be sensitive, i.e. 24 hpf lethality and 96 hpf abnormality of zebrafish embryos, as well as the inhibition rate for luminous bacteria Q67. It is therefore recommended that these indexes could be incorporated into the traditional Nemerow method to provide a more reasonable evaluation of the highway runoff quality and ecotoxicity. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Sports Injury Surveillance Systems: A Review of Methods and Data Quality.

    PubMed

    Ekegren, Christina L; Gabbe, Belinda J; Finch, Caroline F

    2016-01-01

    Data from sports injury surveillance systems are a prerequisite to the development and evaluation of injury prevention strategies. This review aimed to identify ongoing sports injury surveillance systems and determine whether there are gaps in our understanding of injuries in certain sport settings. A secondary aim was to determine which of the included surveillance systems have evaluated the quality of their data, a key factor in determining their usefulness. A systematic search was carried out to identify (1) publications presenting methodological details of sports injury surveillance systems within clubs and organisations; and (2) publications describing quality evaluations and the quality of data from these systems. Data extracted included methodological details of the surveillance systems, methods used to evaluate data quality, and results of these evaluations. Following literature search and review, a total of 15 sports injury surveillance systems were identified. Data relevant to each aim were summarised descriptively. Most systems were found to exist within professional and elite sports. Publications concerning data quality were identified for seven (47%) systems. Validation of system data through comparison with alternate sources has been undertaken for only four systems (27%). This review identified a shortage of ongoing injury surveillance data from amateur and community sport settings and limited information about the quality of data in professional and elite settings. More surveillance systems are needed across a range of sport settings, as are standards for data quality reporting. These efforts will enable better monitoring of sports injury trends and the development of sports safety strategies.

  5. Models and Methods of Aggregating Linguistic Information in Multi-criteria Hierarchical Quality Assessment Systems

    NASA Astrophysics Data System (ADS)

    Azarnova, T. V.; Titova, I. A.; Barkalov, S. A.

    2018-03-01

    The article presents an algorithm for obtaining an integral assessment of the quality of an organization from the perspective of customers, based on the method of aggregating linguistic information on a multilevel hierarchical system of quality assessment. The algorithm is of a constructive nature, it provides not only the possibility of obtaining an integral evaluation, but also the development of a quality improvement strategy based on the method of linguistic decomposition, which forms the minimum set of areas of work with clients whose quality change will allow obtaining the required level of integrated quality assessment.

  6. Intergenerational volunteering and quality of life: mixed methods evaluation of a randomized control trial involving persons with mild to moderate dementia.

    PubMed

    George, Daniel R

    2011-09-01

    This article reports on a mixed methods evaluation of a randomized control trial in Cleveland, Ohio, USA, that assessed whether an intergenerational volunteering intervention could enhance quality of life (QOL) for persons with mild to moderate dementia. Fifteen participants were randomized into intervention and control groups. The intervention group participated in hour-long volunteer sessions with a kindergarten class and an older elementary class in alternating weeks over a 5-month interval. Psychometric data on cognitive functioning, stress, depression, sense of purpose, and sense of usefulness were collected at baseline and at the close of the intervention, and change scores were computed and analyzed for all variables. Ethnography was carried out through the duration of the study, and narrative interviews were held with participants and caregivers. A modified grounded theory approach was used for qualitative analysis. Quantitative analysis demonstrated a significant decrease in stress for the intervention group. Qualitative analysis identified three main pathways through which intergenerational volunteering affected QOL: perceived health benefits, sense of purpose and sense of usefulness, and relationships. Mixed methods evaluation demonstrated that intergenerational volunteering might enhance quality of life through several key pathways, most significantly reduced stress.

  7. Inverse simulation system for evaluating handling qualities during rendezvous and docking

    NASA Astrophysics Data System (ADS)

    Zhou, Wanmeng; Wang, Hua; Thomson, Douglas; Tang, Guojin; Zhang, Fan

    2017-08-01

    The traditional method used for handling qualities assessment of manned space vehicles is too time-consuming to meet the requirements of an increasingly fast design process. In this study, a rendezvous and docking inverse simulation system to assess the handling qualities of spacecraft is proposed using a previously developed model-predictive-control architecture. By considering the fixed discrete force of the thrusters of the system, the inverse model is constructed using the least squares estimation method with a hyper-ellipsoidal restriction, the continuous control outputs of which are subsequently dispersed by pulse width modulation with sensitivity factors introduced. The inputs in every step are deemed constant parameters, and the method could be considered as a general method for solving nominal, redundant, and insufficient inverse problems. The rendezvous and docking inverse simulation is applied to a nine-degrees-of-freedom platform, and a novel handling qualities evaluation scheme is established according to the operation precision and astronauts' workload. Finally, different nominal trajectories are scored by the inverse simulation and an established evaluation scheme. The scores can offer theoretical guidance for astronaut training and more complex operation missions.

  8. A Preliminary Rubric Design to Evaluate Mixed Methods Research

    ERIC Educational Resources Information Center

    Burrows, Timothy J.

    2013-01-01

    With the increase in frequency of the use of mixed methods, both in research publications and in externally funded grants there are increasing calls for a set of standards to assess the quality of mixed methods research. The purpose of this mixed methods study was to conduct a multi-phase analysis to create a preliminary rubric to evaluate mixed…

  9. Grid mapping: a novel method of signal quality evaluation on a single lead electrocardiogram.

    PubMed

    Li, Yanjun; Tang, Xiaoying

    2017-12-01

    Diagnosis of long-term electrocardiogram (ECG) calls for automatic and accurate methods of ECG signal quality estimation, not only to lighten the burden of the doctors but also to avoid misdiagnoses. In this paper, a novel waveform-based method of phase-space reconstruction for signal quality estimation on a single lead ECG was proposed by projecting the amplitude of the ECG and its first order difference into grid cells. The waveform of a single lead ECG was divided into non-overlapping episodes (T s  = 10, 20, 30 s), and the number of grids in both the width and the height of each map are in the range [20, 100] (N X  = N Y  = 20, 30, 40, … 90, 100). The blank pane ratio (BPR) and the entropy were calculated from the distribution of ECG sampling points which were projected into the grid cells. Signal Quality Indices (SQI) bSQI and eSQI were calculated according to the BPR and the entropy, respectively. The MIT-BIH Noise Stress Test Database was used to test the performance of bSQI and eSQI on ECG signal quality estimation. The signal-to-noise ratio (SNR) during the noisy segments of the ECG records in the database is 24, 18, 12, 6, 0 and - 6 dB, respectively. For the SQI quantitative analysis, the records were divided into three groups: good quality group (24, 18 dB), moderate group (12, 6 dB) and bad quality group (0, - 6 dB). The classification among good quality group, moderate quality group and bad quality group were made by linear support-vector machine with the combination of the BPR, the entropy, the bSQI and the eSQI. The classification accuracy was 82.4% and the Cohen's Kappa coefficient was 0.74 on a scale of N X  = 40 and T s  = 20 s. In conclusion, the novel grid mapping offers an intuitive and simple approach to achieving signal quality estimation on a single lead ECG.

  10. Evaluating Sleep Disturbance: A Review of Methods

    NASA Technical Reports Server (NTRS)

    Smith, Roy M.; Oyung, R.; Gregory, K.; Miller, D.; Rosekind, M.; Rosekind, Mark R. (Technical Monitor)

    1996-01-01

    There are three general approaches to evaluating sleep disturbance in regards to noise: subjective, behavioral, and physiological. Subjective methods range from standardized questionnaires and scales to self-report measures designed for specific research questions. There are two behavioral methods that provide useful sleep disturbance data. One behavioral method is actigraphy, a motion detector that provides an empirical estimate of sleep quantity and quality. An actigraph, worn on the non-dominant wrist, provides a 24-hr estimate of the rest/activity cycle. The other method involves a behavioral response, either to a specific probe or stimuli or subject initiated (e.g., indicating wakefulness). The classic, gold standard for evaluating sleep disturbance is continuous physiological monitoring of brain, eye, and muscle activity. This allows detailed distinctions of the states and stages of sleep, awakenings, and sleep continuity. Physiological delta can be obtained in controlled laboratory settings and in natural environments. Current ambulatory physiological recording equipment allows evaluation in home and work settings. These approaches will be described and the relative strengths and limitations of each method will be discussed.

  11. QoE collaborative evaluation method based on fuzzy clustering heuristic algorithm.

    PubMed

    Bao, Ying; Lei, Weimin; Zhang, Wei; Zhan, Yuzhuo

    2016-01-01

    At present, to realize or improve the quality of experience (QoE) is a major goal for network media transmission service, and QoE evaluation is the basis for adjusting the transmission control mechanism. Therefore, a kind of QoE collaborative evaluation method based on fuzzy clustering heuristic algorithm is proposed in this paper, which is concentrated on service score calculation at the server side. The server side collects network transmission quality of service (QoS) parameter, node location data, and user expectation value from client feedback information. Then it manages the historical data in database through the "big data" process mode, and predicts user score according to heuristic rules. On this basis, it completes fuzzy clustering analysis, and generates service QoE score and management message, which will be finally fed back to clients. Besides, this paper mainly discussed service evaluation generative rules, heuristic evaluation rules and fuzzy clustering analysis methods, and presents service-based QoE evaluation processes. The simulation experiments have verified the effectiveness of QoE collaborative evaluation method based on fuzzy clustering heuristic rules.

  12. Classification and Quality Evaluation of Tobacco Leaves Based on Image Processing and Fuzzy Comprehensive Evaluation

    PubMed Central

    Zhang, Fan; Zhang, Xinhong

    2011-01-01

    Most of classification, quality evaluation or grading of the flue-cured tobacco leaves are manually operated, which relies on the judgmental experience of experts, and inevitably limited by personal, physical and environmental factors. The classification and the quality evaluation are therefore subjective and experientially based. In this paper, an automatic classification method of tobacco leaves based on the digital image processing and the fuzzy sets theory is presented. A grading system based on image processing techniques was developed for automatically inspecting and grading flue-cured tobacco leaves. This system uses machine vision for the extraction and analysis of color, size, shape and surface texture. Fuzzy comprehensive evaluation provides a high level of confidence in decision making based on the fuzzy logic. The neural network is used to estimate and forecast the membership function of the features of tobacco leaves in the fuzzy sets. The experimental results of the two-level fuzzy comprehensive evaluation (FCE) show that the accuracy rate of classification is about 94% for the trained tobacco leaves, and the accuracy rate of the non-trained tobacco leaves is about 72%. We believe that the fuzzy comprehensive evaluation is a viable way for the automatic classification and quality evaluation of the tobacco leaves. PMID:22163744

  13. 48 CFR 246.470-2 - Quality evaluation data.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 246.470-2 Quality evaluation data. The contract administration office shall establish a system for the collection, evaluation, and use of the types of quality evaluation data specified in PGI 246.470-2. [71 FR... 48 Federal Acquisition Regulations System 3 2012-10-01 2012-10-01 false Quality evaluation data...

  14. 48 CFR 246.470-2 - Quality evaluation data.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 246.470-2 Quality evaluation data. The contract administration office shall establish a system for the collection, evaluation, and use of the types of quality evaluation data specified in PGI 246.470-2. [71 FR... 48 Federal Acquisition Regulations System 3 2013-10-01 2013-10-01 false Quality evaluation data...

  15. 48 CFR 246.470-2 - Quality evaluation data.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 246.470-2 Quality evaluation data. The contract administration office shall establish a system for the collection, evaluation, and use of the types of quality evaluation data specified in PGI 246.470-2. [71 FR... 48 Federal Acquisition Regulations System 3 2014-10-01 2014-10-01 false Quality evaluation data...

  16. 48 CFR 246.470-2 - Quality evaluation data.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 246.470-2 Quality evaluation data. The contract administration office shall establish a system for the collection, evaluation, and use of the types of quality evaluation data specified in PGI 246.470-2. [71 FR... 48 Federal Acquisition Regulations System 3 2011-10-01 2011-10-01 false Quality evaluation data...

  17. Use of refractometry and colorimetry as field methods to rapidly assess antimalarial drug quality.

    PubMed

    Green, Michael D; Nettey, Henry; Villalva Rojas, Ofelia; Pamanivong, Chansapha; Khounsaknalath, Lamphet; Grande Ortiz, Miguel; Newton, Paul N; Fernández, Facundo M; Vongsack, Latsamy; Manolin, Ot

    2007-01-04

    The proliferation of counterfeit and poor-quality drugs is a major public health problem; especially in developing countries lacking adequate resources to effectively monitor their prevalence. Simple and affordable field methods provide a practical means of rapidly monitoring drug quality in circumstances where more advanced techniques are not available. Therefore, we have evaluated refractometry, colorimetry and a technique combining both processes as simple and accurate field assays to rapidly test the quality of the commonly available antimalarial drugs; artesunate, chloroquine, quinine, and sulfadoxine. Method bias, sensitivity, specificity and accuracy relative to high-performance liquid chromatographic (HPLC) analysis of drugs collected in the Lao PDR were assessed for each technique. The HPLC method for each drug was evaluated in terms of assay variability and accuracy. The accuracy of the combined method ranged from 0.96 to 1.00 for artesunate tablets, chloroquine injectables, quinine capsules, and sulfadoxine tablets while the accuracy was 0.78 for enterically coated chloroquine tablets. These techniques provide a generally accurate, yet simple and affordable means to assess drug quality in resource-poor settings.

  18. Evaluating the Relationship between Productivity and Quality in Emergency Departments

    PubMed Central

    Bastian, Nathaniel D.; Riordan, John P.

    2017-01-01

    Background In the United States, emergency departments (EDs) are constantly pressured to improve operational efficiency and quality in order to gain financial benefits and maintain a positive reputation. Objectives The first objective is to evaluate how efficiently EDs transform their input resources into quality outputs. The second objective is to investigate the relationship between the efficiency and quality performance of EDs and the factors affecting this relationship. Methods Using two data sources, we develop a data envelopment analysis (DEA) model to evaluate the relative efficiency of EDs. Based on the DEA result, we performed multinomial logistic regression to investigate the relationship between ED efficiency and quality performance. Results The DEA results indicated that the main source of inefficiencies was working hours of technicians. The multinomial logistic regression result indicated that the number of electrocardiograms and X-ray procedures conducted in the ED and the length of stay were significantly associated with the trade-offs between relative efficiency and quality. Structural ED characteristics did not influence the relationship between efficiency and quality. Conclusions Depending on the structural and operational characteristics of EDs, different factors can affect the relationship between efficiency and quality. PMID:29065673

  19. Quality measures for nurse practitioner practice evaluation.

    PubMed

    Kleinpell, Ruth; Kapu, April N

    2017-08-01

    Evaluating the impact of nurse practitioner (NP) practice has become a priority area of focus for demonstrating outcomes. A number of quality measures are available to enable practice-specific evaluation of NP roles and initiatives. This article reviews sources of quality measures that can be used to facilitate quantifying the outcomes of NP practice as part of an overall evaluation agenda. National resources and published literature on NP quality measures were reviewed. Various resources and toolkits exist to assist NPs in identifying outcomes of practice using quality measures. The need to demonstrate outcomes of NP practice remains an ongoing priority area regardless of the clinical practice setting. A variety of sources of quality measures exist that can be used to showcase the effect of NP care. The use of quality measures can be effectively integrated into evaluation of NP role and NP-directed initiatives to demonstrate impact, and enhance the conduct of an NP outcomes assessment. The use of organizational, NP-specific, and national-related quality measures can help to showcase how NP care improves the quality, safety, and costs of health care. ©2017 American Association of Nurse Practitioners.

  20. A review of data quality assessment methods for public health information systems.

    PubMed

    Chen, Hong; Hailey, David; Wang, Ning; Yu, Ping

    2014-05-14

    High quality data and effective data quality assessment are required for accurately evaluating the impact of public health interventions and measuring public health outcomes. Data, data use, and data collection process, as the three dimensions of data quality, all need to be assessed for overall data quality assessment. We reviewed current data quality assessment methods. The relevant study was identified in major databases and well-known institutional websites. We found the dimension of data was most frequently assessed. Completeness, accuracy, and timeliness were the three most-used attributes among a total of 49 attributes of data quality. The major quantitative assessment methods were descriptive surveys and data audits, whereas the common qualitative assessment methods were interview and documentation review. The limitations of the reviewed studies included inattentiveness to data use and data collection process, inconsistency in the definition of attributes of data quality, failure to address data users' concerns and a lack of systematic procedures in data quality assessment. This review study is limited by the coverage of the databases and the breadth of public health information systems. Further research could develop consistent data quality definitions and attributes. More research efforts should be given to assess the quality of data use and the quality of data collection process.

  1. A Review of Data Quality Assessment Methods for Public Health Information Systems

    PubMed Central

    Chen, Hong; Hailey, David; Wang, Ning; Yu, Ping

    2014-01-01

    High quality data and effective data quality assessment are required for accurately evaluating the impact of public health interventions and measuring public health outcomes. Data, data use, and data collection process, as the three dimensions of data quality, all need to be assessed for overall data quality assessment. We reviewed current data quality assessment methods. The relevant study was identified in major databases and well-known institutional websites. We found the dimension of data was most frequently assessed. Completeness, accuracy, and timeliness were the three most-used attributes among a total of 49 attributes of data quality. The major quantitative assessment methods were descriptive surveys and data audits, whereas the common qualitative assessment methods were interview and documentation review. The limitations of the reviewed studies included inattentiveness to data use and data collection process, inconsistency in the definition of attributes of data quality, failure to address data users’ concerns and a lack of systematic procedures in data quality assessment. This review study is limited by the coverage of the databases and the breadth of public health information systems. Further research could develop consistent data quality definitions and attributes. More research efforts should be given to assess the quality of data use and the quality of data collection process. PMID:24830450

  2. Value for money of changing healthcare services? Economic evaluation of quality improvement

    PubMed Central

    Severens, J

    2003-01-01

    

 There are many instances of perceived or real inefficiencies in health service delivery. Both healthcare providers and policy makers need to know the impact and cost of applying strategies to change the behaviour of individuals or organisations. Quality improvement or implementation research is concerned with evaluating the methods of behavioural change. Addressing inefficiencies in healthcare services raises a series of issues, beginning with how inefficiency itself should be defined. The basic concepts of cost analysis and economic evaluations are explained and a model for working through the economic issues of quality improvement is discussed. This model combines the costs and benefits of corrected inefficiency with the costs and degree of behavioural change achieved by a quality improvement method in the policy maker's locality. It shows why it may not always be cost effective for policy makers to address suboptimal behaviour. Both the interpretation of quality improvement research findings and their local application need careful consideration. The limited availability of applicable quality improvement research may make it difficult to provide robust advice on the value for money of many behavioural quality improvement strategies. PMID:14532369

  3. Integrating empowerment evaluation and quality improvement to achieve healthcare improvement outcomes

    PubMed Central

    Wandersman, Abraham; Alia, Kassandra Ann; Cook, Brittany; Ramaswamy, Rohit

    2015-01-01

    While the body of evidence-based healthcare interventions grows, the ability of health systems to deliver these interventions effectively and efficiently lags behind. Quality improvement approaches, such as the model for improvement, have demonstrated some success in healthcare but their impact has been lessened by implementation challenges. To help address these challenges, we describe the empowerment evaluation approach that has been developed by programme evaluators and a method for its application (Getting To Outcomes (GTO)). We then describe how GTO can be used to implement healthcare interventions. An illustrative healthcare quality improvement example that compares the model for improvement and the GTO method for reducing hospital admissions through improved diabetes care is described. We conclude with suggestions for integrating GTO and the model for improvement. PMID:26178332

  4. Segmentation quality evaluation using region-based precision and recall measures for remote sensing images

    NASA Astrophysics Data System (ADS)

    Zhang, Xueliang; Feng, Xuezhi; Xiao, Pengfeng; He, Guangjun; Zhu, Liujun

    2015-04-01

    Segmentation of remote sensing images is a critical step in geographic object-based image analysis. Evaluating the performance of segmentation algorithms is essential to identify effective segmentation methods and optimize their parameters. In this study, we propose region-based precision and recall measures and use them to compare two image partitions for the purpose of evaluating segmentation quality. The two measures are calculated based on region overlapping and presented as a point or a curve in a precision-recall space, which can indicate segmentation quality in both geometric and arithmetic respects. Furthermore, the precision and recall measures are combined by using four different methods. We examine and compare the effectiveness of the combined indicators through geometric illustration, in an effort to reveal segmentation quality clearly and capture the trade-off between the two measures. In the experiments, we adopted the multiresolution segmentation (MRS) method for evaluation. The proposed measures are compared with four existing discrepancy measures to further confirm their capabilities. Finally, we suggest using a combination of the region-based precision-recall curve and the F-measure for supervised segmentation evaluation.

  5. [Application of relative quality constant in grades evaluation of Glycyrrizae Radix et Rhizome pieces].

    PubMed

    Deng, Zhe; Jiao, Meng-Jiao; Zhang, Jun; Xian, Jing; Zhang, Qing; Chen, Chang; Wang, Yue-Sheng; Liu, An

    2017-07-01

    Quality constant evaluation is a comprehensive method for grades evaluation of traditional Chinese medicine pieces, but when it comes to Glycyrrizae Radix et Rhizome pieces, grades evaluation is diverged due to significant difference in contents of liquiritin and glycyrrhizic acid and unreasonable weight of index. To solve this problem, we have established a relative quality constant method in this paper to evaluate grades of Glycyrrizae Radix et Rhizome pieces. Twenty-nine batches of different quality samples were collected and tested, and finally, 17 batches of them were chosen as researcher objects. The results revealed that the range of the relative quality constant of these samples was from 1.78 to 11.49. When Glycyrrizae Radix et Rhizome pieces are divided into three grades: the relative quality constant of first grade is greater than or equal to 9.19; the second grade is greater than or equal to 5.75 but less than 9.19; while the third grade is less than 5.75. This research indicates that relative quality constant can divide the grades of herbal pieces in a scientific, reasonable, objective and specific way and remedy the shortage of quality constant perfectly. It provides a novel mode for grading pieces of Chinese medicine that contains multi-target ingredients. Copyright© by the Chinese Pharmaceutical Association.

  6. Evaluating quality in endoscopy.

    PubMed

    Pohl, Heiko

    2017-06-01

    Despite an increasing number of publications and suggested quality measures, evaluating quality in endoscopy remains a challenge. Most quality measures are process measures and lack evidence for an association with clinically important outcomes. Furthermore, most measure focus on procedural aspects. Patients' expectations, cultural values, and work setting also affect quality, but are less often considered. The aim of this article is to broaden the view on quality assessment. Here, quality is viewed from four perspectives: an individual patient perspective, which considers expectations and personal values; a cultural perspective, which encompasses cultural values and norms; an individual care perspective, which includes how an individual patient is being treated; and a societal perspective, which sets the stage for provided care. The article concludes with a proposal to consider bundled composite measures as a path to a simple yet comprehensive approach to assessing and measuring quality in endoscopy. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Qualitative evaluations and comparisons of six night-vision colorization methods

    NASA Astrophysics Data System (ADS)

    Zheng, Yufeng; Reese, Kristopher; Blasch, Erik; McManamon, Paul

    2013-05-01

    Current multispectral night vision (NV) colorization techniques can manipulate images to produce colorized images that closely resemble natural scenes. The colorized NV images can enhance human perception by improving observer object classification and reaction times especially for low light conditions. This paper focuses on the qualitative (subjective) evaluations and comparisons of six NV colorization methods. The multispectral images include visible (Red-Green- Blue), near infrared (NIR), and long wave infrared (LWIR) images. The six colorization methods are channel-based color fusion (CBCF), statistic matching (SM), histogram matching (HM), joint-histogram matching (JHM), statistic matching then joint-histogram matching (SM-JHM), and the lookup table (LUT). Four categries of quality measurements are used for the qualitative evaluations, which are contrast, detail, colorfulness, and overall quality. The score of each measurement is rated from 1 to 3 scale to represent low, average, and high quality, respectively. Specifically, high contrast (of rated score 3) means an adequate level of brightness and contrast. The high detail represents high clarity of detailed contents while maintaining low artifacts. The high colorfulness preserves more natural colors (i.e., closely resembles the daylight image). Overall quality is determined from the NV image compared to the reference image. Nine sets of multispectral NV images were used in our experiments. For each set, the six colorized NV images (produced from NIR and LWIR images) are concurrently presented to users along with the reference color (RGB) image (taken at daytime). A total of 67 subjects passed a screening test ("Ishihara Color Blindness Test") and were asked to evaluate the 9-set colorized images. The experimental results showed the quality order of colorization methods from the best to the worst: CBCF < SM < SM-JHM < LUT < JHM < HM. It is anticipated that this work will provide a benchmark for NV

  8. Improving Reference Service: The Case for Using a Continuous Quality Improvement Method.

    ERIC Educational Resources Information Center

    Aluri, Rao

    1993-01-01

    Discusses the evaluation of library reference service; examines problems with past evaluations, including the lack of long-term planning and a systems perspective; and suggests a method for continuously monitoring and improving reference service using quality improvement tools such as checklists, cause and effect diagrams, Pareto charts, and…

  9. Empirical evaluation of humpback whale telomere length estimates; quality control and factors causing variability in the singleplex and multiplex qPCR methods

    PubMed Central

    2012-01-01

    Background Telomeres, the protective cap of chromosomes, have emerged as powerful markers of biological age and life history in model and non-model species. The qPCR method for telomere length estimation is one of the most common methods for telomere length estimation, but has received recent critique for being too error-prone and yielding unreliable results. This critique coincides with an increasing awareness of the potentials and limitations of the qPCR technique in general and the proposal of a general set of guidelines (MIQE) for standardization of experimental, analytical, and reporting steps of qPCR. In order to evaluate the utility of the qPCR method for telomere length estimation in non-model species, we carried out four different qPCR assays directed at humpback whale telomeres, and subsequently performed a rigorous quality control to evaluate the performance of each assay. Results Performance differed substantially among assays and only one assay was found useful for telomere length estimation in humpback whales. The most notable factors causing these inter-assay differences were primer design and choice of using singleplex or multiplex assays. Inferred amplification efficiencies differed by up to 40% depending on assay and quantification method, however this variation only affected telomere length estimates in the worst performing assays. Conclusion Our results suggest that seemingly well performing qPCR assays may contain biases that will only be detected by extensive quality control. Moreover, we show that the qPCR method for telomere length estimation can be highly precise and accurate, and thus suitable for telomere measurement in non-model species, if effort is devoted to optimization at all experimental and analytical steps. We conclude by highlighting a set of quality controls which may serve for further standardization of the qPCR method for telomere length estimation, and discuss some of the factors that may cause variation in qPCR experiments

  10. Strapdown Airborne Gravimetry Quality Assessment Method Based on Single Survey Line Data: A Study by SGA-WZ02 Gravimeter

    PubMed Central

    Wu, Meiping; Cao, Juliang; Zhang, Kaidong; Cai, Shaokun; Yu, Ruihang

    2018-01-01

    Quality assessment is an important part in the strapdown airborne gravimetry. Root mean square error (RMSE) evaluation method is a classical way to evaluate the gravimetry quality, but classical evaluation methods are preconditioned by extra flight or reference data. Thus, a method, which is able to largely conquer the premises of classical quality assessment methods and can be used in single survey line, has been developed in this paper. According to theoretical analysis, the method chooses the stability of two horizontal attitude angles, horizontal specific force and vertical specific force as the determinants of quality assessment method. The actual data, collected by SGA-WZ02 from 13 flights 21 lines in certain survey, was used to build the model and elaborate the method. To substantiate the performance of the quality assessment model, the model is applied in extra repeat line flights from two surveys. Compared with internal RMSE, standard deviation of assessment residuals are 0.23 mGal and 0.16 mGal in two surveys, which shows that the quality assessment method is reliable and stricter. The extra flights are not necessary by specially arranging the route of flights. The method, summarized from SGA-WZ02, is a feasible approach to assess gravimetry quality using single line data and is also suitable for other strapdown gravimeters. PMID:29373535

  11. Describing methods and interventions: a protocol for the systematic analysis of the perioperative quality improvement literature.

    PubMed

    Jones, Emma; Lees, Nicholas; Martin, Graham; Dixon-Woods, Mary

    2014-09-05

    Quality improvement (QI) methods are widely used in surgery in an effort to improve care, often using techniques such as Plan-Do-Study-Act cycles to implement specific interventions. Explicit definition of both the QI method and quality intervention is necessary to enable the accurate replication of effective interventions in practice, facilitate cumulative learning, reduce research waste and optimise benefits to patients. This systematic review aims to assess quality of reporting of QI methods and quality interventions in perioperative care. Studies reporting on quality interventions implemented in perioperative care settings will be identified. Searches will be conducted in the Ovid SP version of Medline, Scopus, the Cochrane Central Register of Controlled Trials, the Cochrane Effective Practice and Organisation of Care database and the related articles function of PubMed. The journal BMJ Quality will be searched separately. Search strategy terms will relate to (i) surgery, (ii) QI and (iii) evaluation methods. Explicit exclusion and inclusion criteria will be applied. Data from studies will be extracted using a data extraction form. The Template for Intervention Description and Replication (TIDieR) checklist will be used to evaluate quality of reporting, together with additional items aimed at assessing QI methods specifically. PROSPERO http://CRD42014012845.

  12. 48 CFR 246.470-2 - Quality evaluation data.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Quality evaluation data... SYSTEM, DEPARTMENT OF DEFENSE CONTRACT MANAGEMENT QUALITY ASSURANCE Government Contract Quality Assurance 246.470-2 Quality evaluation data. The contract administration office shall establish a system for the...

  13. Comparing different methods for fast screening of microbiological quality of beach sand aimed at rapid-response remediation.

    PubMed

    Testolin, Renan C; Almeida, Tito C M; Polette, Marcus; Branco, Joaquim O; Fischer, Larissa L; Niero, Guilherme; Poyer-Radetski, Gabriel; Silva, Valéria C; Somensi, Cleder A; Corrêa, Albertina X R; Corrêa, Rogério; Rörig, Leonardo R; Itokazu, Ana Gabriela; Férard, Jean-François; Cotelle, Sylvie; Radetski, Claudemir M

    2017-05-15

    There is scientific evidence that beach sands are a significant contributor to the pathogen load to which visitors are exposed. To develop beach quality guidelines all beach zones must be included in microbiological evaluations, but monitoring methods for beach sand quality are relatively longstanding, expensive, laborious and require moderate laboratory infrastructure. This paper aimed to evaluate the microorganism activity in different beach zones applying and comparing a classical method of membrane filtration (MF) with two colorimetric screening methods based on fluorescein (FDA) and tetrazolium (TTC) salt biotransformation to evaluate a new rapid and low-cost method for beach sand microbiological contamination assessments. The colorimetric results can help beach managers to evaluate rapidly and at low cost the microbiological quality of different beach zones in order to decide whether remedial actions need to be adopted to prevent exposure of the public to microbes due to beach sand and/or water contamination. Copyright © 2017. Published by Elsevier Ltd.

  14. Towards a Quality Assessment Method for Learning Preference Profiles in Negotiation

    NASA Astrophysics Data System (ADS)

    Hindriks, Koen V.; Tykhonov, Dmytro

    In automated negotiation, information gained about an opponent's preference profile by means of learning techniques may significantly improve an agent's negotiation performance. It therefore is useful to gain a better understanding of how various negotiation factors influence the quality of learning. The quality of learning techniques in negotiation are typically assessed indirectly by means of comparing the utility levels of agreed outcomes and other more global negotiation parameters. An evaluation of learning based on such general criteria, however, does not provide any insight into the influence of various aspects of negotiation on the quality of the learned model itself. The quality may depend on such aspects as the domain of negotiation, the structure of the preference profiles, the negotiation strategies used by the parties, and others. To gain a better understanding of the performance of proposed learning techniques in the context of negotiation and to be able to assess the potential to improve the performance of such techniques a more systematic assessment method is needed. In this paper we propose such a systematic method to analyse the quality of the information gained about opponent preferences by learning in single-instance negotiations. The method includes measures to assess the quality of a learned preference profile and proposes an experimental setup to analyse the influence of various negotiation aspects on the quality of learning. We apply the method to a Bayesian learning approach for learning an opponent's preference profile and discuss our findings.

  15. Method and reporting quality in health professions education research: a systematic review.

    PubMed

    Cook, David A; Levinson, Anthony J; Garside, Sarah

    2011-03-01

    Studies evaluating reporting quality in health professions education (HPE) research have demonstrated deficiencies, but none have used comprehensive reporting standards. Additionally, the relationship between study methods and effect size (ES) in HPE research is unknown. This review aimed to evaluate, in a sample of experimental studies of Internet-based instruction, the quality of reporting, the relationship between reporting and methodological quality, and associations between ES and study methods. We conducted a systematic search of databases including MEDLINE, Scopus, CINAHL, EMBASE and ERIC, for articles published during 1990-2008. Studies (in any language) quantifying the effect of Internet-based instruction in HPE compared with no intervention or other instruction were included. Working independently and in duplicate, we coded reporting quality using the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement, and coded study methods using a modified Newcastle-Ottawa Scale (m-NOS), the Medical Education Research Study Quality Instrument (MERSQI), and the Best Evidence in Medical Education (BEME) global scale. For reporting quality, articles scored a mean±standard deviation (SD) of 51±25% of STROBE elements for the Introduction, 58±20% for the Methods, 50±18% for the Results and 41±26% for the Discussion sections. We found positive associations (all p<0.0001) between reporting quality and MERSQI (ρ=0.64), m-NOS (ρ=0.57) and BEME (ρ=0.58) scores. We explored associations between study methods and knowledge ES by subtracting each study's ES from the pooled ES for studies using that method and comparing these differences between subgroups. Effect sizes in single-group pretest/post-test studies differed from the pooled estimate more than ESs in two-group studies (p=0.013). No difference was found between other study methods (yes/no: representative sample, comparison group from same community, randomised, allocation

  16. Quantifying the quality of medical x-ray images: An evaluation based on normal anatomy for lumbar spine and chest radiography

    NASA Astrophysics Data System (ADS)

    Tingberg, Anders Martin

    Optimisation in diagnostic radiology requires accurate methods for determination of patient absorbed dose and clinical image quality. Simple methods for evaluation of clinical image quality are at present scarce and this project aims at developing such methods. Two methods are used and further developed; fulfillment of image criteria (IC) and visual grading analysis (VGA). Clinical image quality descriptors are defined based on these two methods: image criteria score (ICS) and visual grading analysis score (VGAS), respectively. For both methods the basis is the Image Criteria of the ``European Guidelines on Quality Criteria for Diagnostic Radiographic Images''. Both methods have proved to be useful for evaluation of clinical image quality. The two methods complement each other: IC is an absolute method, which means that the quality of images of different patients and produced with different radiographic techniques can be compared with each other. The separating power of IC is, however, weaker than that of VGA. VGA is the best method for comparing images produced with different radiographic techniques and has strong separating power, but the results are relative, since the quality of an image is compared to the quality of a reference image. The usefulness of the two methods has been verified by comparing the results from both of them with results from a generally accepted method for evaluation of clinical image quality, receiver operating characteristics (ROC). The results of the comparison between the two methods based on visibility of anatomical structures and the method based on detection of pathological structures (free-response forced error) indicate that the former two methods can be used for evaluation of clinical image quality as efficiently as the method based on ROC. More studies are, however, needed for us to be able to draw a general conclusion, including studies of other organs, using other radiographic techniques, etc. The results of the experimental

  17. User-Centered Evaluation of the Quality of Blogs

    ERIC Educational Resources Information Center

    Chuenchom, Sutthinan

    2011-01-01

    Blogs serve multiple purposes, resulting in several types of blogs that vary greatly in terms of quality and content. It is important to evaluate the quality of blogs, which requires appropriate evaluation criteria. Unfortunately, there are minimal studies on framework and the specific criteria and indicators for evaluating the quality of blogs.…

  18. Evaluating University-Industry Collaboration: The European Foundation of Quality Management Excellence Model-Based Evaluation of University-Industry Collaboration

    ERIC Educational Resources Information Center

    Kauppila, Osmo; Mursula, Anu; Harkonen, Janne; Kujala, Jaakko

    2015-01-01

    The growth in university-industry collaboration has resulted in an increasing demand for methods to evaluate it. This paper presents one way to evaluate an organization's collaborative activities based on the European Foundation of Quality Management excellence model. Success factors of collaboration are derived from literature and compared…

  19. Evaluating the implementation of confusion assessment method-intensive care unit using a quality improvement approach.

    PubMed

    Stewart, C; Bench, S

    2018-05-15

    Quality improvement (QI) is a way through which health care delivery can be made safer and more effective. Various models of quality improvement methods exist in health care today. These models can help guide and manage the process of introducing changes into clinical practice. The aim of this project was to implement the use of a delirium assessment tool into three adult critical care units within the same hospital using a QI approach. The objective was to improve the identification and management of delirium. Using the Model for Improvement framework, a multidisciplinary working group was established. A delirium assessment tool was introduced via a series of educational initiatives. New local guidelines regarding the use of delirium assessment and management for the multidisciplinary team were also produced. Audit data were collected at 6 weeks and 5 months post-implementation to evaluate compliance with the use of the tool across three critical care units within a single hospital in London. At 6 weeks, in 134 assessment points out of a possible 202, the tool was deemed to be used appropriately, meaning that 60% of patients received timely assessment; 18% of patients were identified as delirious in audit one. Five months later, only 95 assessment points out of a possible 199 were being appropriately assessed (47%); however, a greater number (32%) were identified as delirious. This project emphasizes the complexity of changing practice in a large busy critical care centre. Despite an initial increase in delirium assessment, this was not sustained over time. The use of a QI model highlights the continuous process of embedding changes into clinical practice and the need to use a QI method that can address the challenging nature of modern health care. QI models guide changes in practice. Consideration should be given to the type of QI model used. © 2018 British Association of Critical Care Nurses.

  20. Evaluation of isolation methods for bacterial RNA quantitation in Dickeya dadantii

    USDA-ARS?s Scientific Manuscript database

    Dickeya dadantii is a difficult source for RNA of a sufficient quality for real-time qRT-PCR analysis of gene expression. Three RNA isolation methods were evaluated for their ability to produce high-quality RNA from this bacterium. Bacterial lysis with Trizol using standard protocols consistently ga...

  1. Academic research groups: evaluation of their quality and quality of their evaluation

    NASA Astrophysics Data System (ADS)

    Berche, Bertrand; Holovatch, Yuri; Kenna, Ralph; Mryglod, Olesya

    2016-02-01

    In recent years, evaluation of the quality of academic research has become an increasingly important and influential business. It determines, often to a large extent, the amount of research funding flowing into universities and similar institutes from governmental agencies and it impacts upon academic careers. Policy makers are becoming increasingly reliant upon, and influenced by, the outcomes of such evaluations. In response, university managers are increasingly attracted to simple metrics as guides to the dynamics of the positions of their various institutions in league tables. However, these league tables are invariably drawn up by inexpert bodies such as newspapers and magazines, using arbitrary measures and criteria. Terms such as “critical mass” and “h-index” are bandied about without understanding of what they actually mean. Rather than accepting the rise and fall of universities, departments and individuals on a turbulent sea of arbitrary measures, we suggest it is incumbent upon the scientific community itself to clarify their nature. Here we report on recent attempts to do that by properly defining critical mass and showing how group size influences research quality. We also examine currently predominant metrics and show that these fail as reliable indicators of group research quality.

  2. Evaluation of passenger health risk assessment of sustainable indoor air quality monitoring in metro systems based on a non-Gaussian dynamic sensor validation method.

    PubMed

    Kim, MinJeong; Liu, Hongbin; Kim, Jeong Tai; Yoo, ChangKyoo

    2014-08-15

    Sensor faults in metro systems provide incorrect information to indoor air quality (IAQ) ventilation systems, resulting in the miss-operation of ventilation systems and adverse effects on passenger health. In this study, a new sensor validation method is proposed to (1) detect, identify and repair sensor faults and (2) evaluate the influence of sensor reliability on passenger health risk. To address the dynamic non-Gaussianity problem of IAQ data, dynamic independent component analysis (DICA) is used. To detect and identify sensor faults, the DICA-based squared prediction error and sensor validity index are used, respectively. To restore the faults to normal measurements, a DICA-based iterative reconstruction algorithm is proposed. The comprehensive indoor air-quality index (CIAI) that evaluates the influence of the current IAQ on passenger health is then compared using the faulty and reconstructed IAQ data sets. Experimental results from a metro station showed that the DICA-based method can produce an improved IAQ level in the metro station and reduce passenger health risk since it more accurately validates sensor faults than do conventional methods. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. An evaluation of methods used to teach quality improvement to undergraduate healthcare students to inform curriculum development within preregistration nurse education: a protocol for systematic review and narrative synthesis.

    PubMed

    Armstrong, Lorraine; Lauder, William; Shepherd, Ashley

    2015-01-14

    Despite criticism, quality improvement (QI) continues to drive political and educational priorities within health care. Until recently, QI educational interventions have varied, targeting mainly postgraduates, middle management and the medical profession. However, there is now consensus within the UK, USA and beyond to integrate QI explicitly into nurse education, and faculties may require redesign of their QI curriculum to achieve this. Whilst growth in QI preregistration nurse education is emerging, little empirical evidence exists to determine such effects. Furthermore, previous healthcare studies evaluating QI educational interventions lend little in the way of support and have instead been subject to criticism. They reveal methodological weakness such as no reporting of theoretical underpinnings, insufficient intervention description, poor evaluation methods, little clinical or patient impact and lack of sustainability. This study aims therefore to identify, evaluate and synthesise teaching methods used within the undergraduate population to aid development of QI curriculum within preregistration nurse education. A systematic review of the literature will be conducted. Electronic databases, Cumulative Index to Nursing and Allied Health Literature (CINAHL), Psychological Information (PsychINFO), Education Resources Information Centre (ERIC), Medical Literature Analysis and Retrieval System Online (MEDLINE) and Applied Social Sciences Index and Abstracts (ASSIA), will be searched alongside reference list scanning and a grey literature search. Peer-reviewed studies from 2000-2014 will be identified using key terms quality improvement, education, curriculum, training, undergraduate, teaching methods, students and evaluation. Studies describing a QI themed educational intervention aimed at undergraduate healthcare students will be included and data extracted using a modified version of the Reporting of Primary Studies in Education (REPOSE) Guidelines. Studies will

  4. Evaluation of the quality of herbal teas by DART/TOF-MS.

    PubMed

    Prchalová, J; Kovařík, F; Rajchl, A

    2017-02-01

    The paper focuses on the optimization, settings and validation of direct analysis in real time coupled with time-of-flight detector when used for the evaluation of the quality of selected herbal teas (fennel, chamomile, nettle, linden, peppermint, thyme, lemon balm, marigold, sage, rose hip and St. John's wort). The ionization mode, the optimal ionization temperature and the type of solvent for sample extraction were optimized. The characteristic compounds of the analysed herbal teas (glycosides, flavonoids and phenolic and terpenic substances, such as chamazulene, anethole, menthol, thymol, salviol and hypericin) were detected. The obtained mass spectra were evaluated by multidimensional chemometric methods, such as cluster analysis, linear discriminate analysis and principal component analysis. The chemometric methods showed that the single variety herbal teas were grouped according to their taxonomic affiliation. The developed method is suitable for quick identification of herbs and can be potentially used for assessing the quality and authenticity of herbal teas. Direct analysis in real time/time-of-flight-MS is also suitable for the evaluation of selected substances contained in the mentioned herbs and herbal products. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  5. The usefulness of Quality of Life Childhood Epilepsy (QOLCE) questionnaire in evaluating the quality of life of children with epilepsy.

    PubMed

    Talarska, D

    2007-01-01

    Evaluation of quality of life has become a frequently used method in treatment effects supervision. Quality of Life Childhood Epilepsy (QOLCE) questionnaire, which is completed by patients' parents, has been prepared for children with epilepsy. It enables to determine the quality of life in children aged 4-18 years. The aim of the study was to show the usefulness of QOLCE questionnaire in evaluating the quality of life of children with epilepsy. 160 epileptic children, aged 8-18 years and their parents were examined in the Chair and Department of Developmental Neurology, K. Marcinkowski University of Medical Sciences in Poznań. QOLCE questionnaire was completed by parents and "Young people and epilepsy" questionnaire was designed for children. Reliability index of the complete questionnaire in own research and in the original amounted to 0.93 Cronbach alpha coefficient. Epileptic, drug-resistant children constituted 28% of the examined group. Parents of children with controlled seizures evaluated children's functioning in analyzed areas of quality of life higher. 1. QOLCE questionnaire is a suitable tool to evaluate the quality of children's and adolescents' life. 2. The most significant differences in functioning of epileptic, drug-resistant patients and those with controlled seizures were observed in areas of cognitive processes and social activity.

  6. Image quality evaluation of eight complementary metal-oxide semiconductor intraoral digital X-ray sensors.

    PubMed

    Teich, Sorin; Al-Rawi, Wisam; Heima, Masahiro; Faddoul, Fady F; Goldzweig, Gil; Gutmacher, Zvi; Aizenbud, Dror

    2016-10-01

    To evaluate the image quality generated by eight commercially available intraoral sensors. Eighteen clinicians ranked the quality of a bitewing acquired from one subject using eight different intraoral sensors. Analytical methods used to evaluate clinical image quality included the Visual Grading Characteristics method, which helps to quantify subjective opinions to make them suitable for analysis. The Dexis sensor was ranked significantly better than Sirona and Carestream-Kodak sensors; and the image captured using the Carestream-Kodak sensor was ranked significantly worse than those captured using Dexis, Schick and Cyber Medical Imaging sensors. The Image Works sensor image was rated the lowest by all clinicians. Other comparisons resulted in non-significant results. None of the sensors was considered to generate images of significantly better quality than the other sensors tested. Further research should be directed towards determining the clinical significance of the differences in image quality reported in this study. © 2016 FDI World Dental Federation.

  7. A fuzzy MCDM model with objective and subjective weights for evaluating service quality in hotel industries

    NASA Astrophysics Data System (ADS)

    Zoraghi, Nima; Amiri, Maghsoud; Talebi, Golnaz; Zowghi, Mahdi

    2013-12-01

    This paper presents a fuzzy multi-criteria decision-making (FMCDM) model by integrating both subjective and objective weights for ranking and evaluating the service quality in hotels. The objective method selects weights of criteria through mathematical calculation, while the subjective method uses judgments of decision makers. In this paper, we use a combination of weights obtained by both approaches in evaluating service quality in hotel industries. A real case study that considered ranking five hotels is illustrated. Examples are shown to indicate capabilities of the proposed method.

  8. Tweets about hospital quality: a mixed methods study

    PubMed Central

    Greaves, Felix; Laverty, Antony A; Cano, Daniel Ramirez; Moilanen, Karo; Pulman, Stephen; Darzi, Ara; Millett, Christopher

    2014-01-01

    Background Twitter is increasingly being used by patients to comment on their experience of healthcare. This may provide information for understanding the quality of healthcare providers and improving services. Objective To examine whether tweets sent to hospitals in the English National Health Service contain information about quality of care. To compare sentiment on Twitter about hospitals with established survey measures of patient experience and standardised mortality rates. Design A mixed methods study including a quantitative analysis of all 198 499 tweets sent to English hospitals over a year and a qualitative directed content analysis of 1000 random tweets. Twitter sentiment and conventional quality metrics were compared using Spearman's rank correlation coefficient. Key results 11% of tweets to hospitals contained information about care quality, with the most frequent topic being patient experience (8%). Comments on effectiveness or safety of care were present, but less common (3%). 77% of tweets about care quality were positive in tone. Other topics mentioned in tweets included messages of support to patients, fundraising activity, self-promotion and dissemination of health information. No associations were observed between Twitter sentiment and conventional quality metrics. Conclusions Only a small proportion of tweets directed at hospitals discuss quality of care and there was no clear relationship between Twitter sentiment and other measures of quality, potentially limiting Twitter as a medium for quality monitoring. However, tweets did contain information useful to target quality improvement activity. Recent enthusiasm by policy makers to use social media as a quality monitoring and improvement tool needs to be carefully considered and subjected to formal evaluation. PMID:24748372

  9. Evaluation of pH monitoring as a method of processor control.

    PubMed

    Stears, J G; Gray, J E; Winkler, N T

    1979-01-01

    Sensitometry and pH values of the developer solution were compared in controlled over-replenishment, developer depletion, fixer contamination experiments, and on a daily quality control basis. The purpose of these comparisons was to evaluate the potential of pH monitoring as a method of processor control, or a supplement to sensitometry as a method of quality control. Reasonable correlation was found between pH values and film density in two of the three experiments but little or no correlation was found in the third experiment and on a day-to-day basis. The conclusion drawn from these comparisons is that pH monitoring has several limitations which render it unsuitable as a method of daily processor quality control as either a primary or supplementary technique. Sensitometry takes into account all the variables encountered in film processing and is the clear method of choice for processor quality control.

  10. Comparison of laboratory and field remote sensing methods to measure forage quality.

    PubMed

    Guo, Xulin; Wilmshurst, John F; Li, Zhaoqin

    2010-09-01

    Recent research in range ecology has emphasized the importance of forage quality as a key indicator of rangeland condition. However, we lack tools to evaluate forage quality at scales appropriate for management. Using canopy reflectance data to measure forage quality has been conducted at both laboratory and field levels separately, but little work has been conducted to evaluate these methods simultaneously. The objective of this study is to find a reliable way of assessing grassland quality through measuring forage chemistry with reflectance. We studied a mixed grass ecosystem in Grasslands National Park of Canada and surrounding pastures, located in southern Saskatchewan. Spectral reflectance was collected at both in-situ field level and in the laboratory. Vegetation samples were collected at each site, sorted into the green grass portion, and then sent to a chemical company for measuring forage quality variables, including protein, lignin, ash, moisture at 135 °C, Neutral Detergent Fiber (NDF), Acid Detergent Fiber (ADF), Total Digestible, Digestible Energy, Net Energy for Lactation, Net Energy for Maintenance, and Net Energy for Gain. Reflectance data were processed with the first derivative transformation and continuum removal method. Correlation analysis was conducted on spectral and forage quality variables. A regression model was further built to investigate the possibility of using canopy spectral measurements to predict the grassland quality. Results indicated that field level prediction of protein of mixed grass species was possible (r² = 0.63). However, the relationship between canopy reflectance and the other forage quality variables was not strong.

  11. Evaluation models and criteria of the quality of hospital websites: a systematic review study

    PubMed Central

    Jeddi, Fatemeh Rangraz; Gilasi, Hamidreza; Khademi, Sahar

    2017-01-01

    Introduction Hospital websites are important tools in establishing communication and exchanging information between patients and staff, and thus should enjoy an acceptable level of quality. The aim of this study was to identify proper models and criteria to evaluate the quality of hospital websites. Methods This research was a systematic review study. The international databases such as Science Direct, Google Scholar, PubMed, Proquest, Ovid, Elsevier, Springer, and EBSCO together with regional database such as Magiran, Scientific Information Database, Persian Journal Citation Report (PJCR) and IranMedex were searched. Suitable keywords including website, evaluation, and quality of website were used. Full text papers related to the research were included. The criteria and sub criteria of the evaluation of website quality were extracted and classified. Results To evaluate the quality of the websites, various models and criteria were presented. The WEB-Q-IM, Mile, Minerva, Seruni Luci, and Web-Qual models were the designed models. The criteria of accessibility, content and apparent features of the websites, the design procedure, the graphics applied in the website, and the page’s attractions have been mentioned in the majority of studies. Conclusion The criteria of accessibility, content, design method, security, and confidentiality of personal information are the essential criteria in the evaluation of all websites. It is suggested that the ease of use, graphics, attractiveness and other apparent properties of websites are considered as the user-friendliness sub criteria. Further, the criteria of speed and accessibility of the website should be considered as sub criterion of efficiency. When determining the evaluation criteria of the quality of websites, attention to major differences in the specific features of any website is essential. PMID:28465807

  12. EVALUATION OF TWO METHODS FOR PREDICTION OF BIOACCUMULATION FACTORS

    EPA Science Inventory

    Two methods for deriving bioaccumulation factors (BAFs) used by the U.S. Environmental Protection Agency (EPA) in development of water quality criteria were evaluated using polychlorinated biphenyls (PCB) data from the Hudson River and Green Bay ecosystems. Greater than 90% of th...

  13. Factor selection for service quality evaluation: a hospital case study.

    PubMed

    Ameryoun, Ahmad; Najafi, Seyedvahid; Nejati-Zarnaqi, Bayram; Khalilifar, Seyed Omid; Ajam, Mahdi; Ansarimoghadam, Ahmad

    2017-02-13

    Purpose The purpose of this paper is to develop a systematic approach to predict service quality dimension's influence on service quality using a novel analysis based on data envelopment and SERVQUAL. Design/methodology/approach To assess hospital service quality in Tehran, expectation and perception of those who received the services were evaluated using SERVQUAL. The hospital service quality dimensions were found by exploratory factor analysis (EFA). To compare customer expectation and perception, perceived service quality index (PSQI) was measured using a new method based on common weights. A novel sensitivity approach was used to test the service quality factor's impact on the PSQI. Findings A new service quality dimension named "trust in services" was found using EFA, which is not an original SERVQUAL factor. The approach was applied to assess the hospital's service quality. Since the PSQI value was 0.76 it showed that improvements are needed to meet customer expectations. The results showed the factor order that affect PSQI. "Trust in services" has the strongest influence on PSQI followed by "tangibles," "assurance," "empathy," and "responsiveness," respectively. Practical implications This work gives managers insight into service quality by following a systematic method; i.e., measuring perceived service quality from the customer viewpoint and service factors' impact on customer perception. Originality/value The procedure helps managers to select the required service quality dimensions which need improvement and predict their effects on customer perception.

  14. An evaluation of methods for estimating decadal stream loads

    NASA Astrophysics Data System (ADS)

    Lee, Casey J.; Hirsch, Robert M.; Schwarz, Gregory E.; Holtschlag, David J.; Preston, Stephen D.; Crawford, Charles G.; Vecchia, Aldo V.

    2016-11-01

    Effective management of water resources requires accurate information on the mass, or load of water-quality constituents transported from upstream watersheds to downstream receiving waters. Despite this need, no single method has been shown to consistently provide accurate load estimates among different water-quality constituents, sampling sites, and sampling regimes. We evaluate the accuracy of several load estimation methods across a broad range of sampling and environmental conditions. This analysis uses random sub-samples drawn from temporally-dense data sets of total nitrogen, total phosphorus, nitrate, and suspended-sediment concentration, and includes measurements of specific conductance which was used as a surrogate for dissolved solids concentration. Methods considered include linear interpolation and ratio estimators, regression-based methods historically employed by the U.S. Geological Survey, and newer flexible techniques including Weighted Regressions on Time, Season, and Discharge (WRTDS) and a generalized non-linear additive model. No single method is identified to have the greatest accuracy across all constituents, sites, and sampling scenarios. Most methods provide accurate estimates of specific conductance (used as a surrogate for total dissolved solids or specific major ions) and total nitrogen - lower accuracy is observed for the estimation of nitrate, total phosphorus and suspended sediment loads. Methods that allow for flexibility in the relation between concentration and flow conditions, specifically Beale's ratio estimator and WRTDS, exhibit greater estimation accuracy and lower bias. Evaluation of methods across simulated sampling scenarios indicate that (1) high-flow sampling is necessary to produce accurate load estimates, (2) extrapolation of sample data through time or across more extreme flow conditions reduces load estimate accuracy, and (3) WRTDS and methods that use a Kalman filter or smoothing to correct for departures between

  15. An evaluation of methods for estimating decadal stream loads

    USGS Publications Warehouse

    Lee, Casey; Hirsch, Robert M.; Schwarz, Gregory E.; Holtschlag, David J.; Preston, Stephen D.; Crawford, Charles G.; Vecchia, Aldo V.

    2016-01-01

    Effective management of water resources requires accurate information on the mass, or load of water-quality constituents transported from upstream watersheds to downstream receiving waters. Despite this need, no single method has been shown to consistently provide accurate load estimates among different water-quality constituents, sampling sites, and sampling regimes. We evaluate the accuracy of several load estimation methods across a broad range of sampling and environmental conditions. This analysis uses random sub-samples drawn from temporally-dense data sets of total nitrogen, total phosphorus, nitrate, and suspended-sediment concentration, and includes measurements of specific conductance which was used as a surrogate for dissolved solids concentration. Methods considered include linear interpolation and ratio estimators, regression-based methods historically employed by the U.S. Geological Survey, and newer flexible techniques including Weighted Regressions on Time, Season, and Discharge (WRTDS) and a generalized non-linear additive model. No single method is identified to have the greatest accuracy across all constituents, sites, and sampling scenarios. Most methods provide accurate estimates of specific conductance (used as a surrogate for total dissolved solids or specific major ions) and total nitrogen – lower accuracy is observed for the estimation of nitrate, total phosphorus and suspended sediment loads. Methods that allow for flexibility in the relation between concentration and flow conditions, specifically Beale’s ratio estimator and WRTDS, exhibit greater estimation accuracy and lower bias. Evaluation of methods across simulated sampling scenarios indicate that (1) high-flow sampling is necessary to produce accurate load estimates, (2) extrapolation of sample data through time or across more extreme flow conditions reduces load estimate accuracy, and (3) WRTDS and methods that use a Kalman filter or smoothing to correct for departures between

  16. Methods for assessing the quality of mammalian embryos: How far we are from the gold standard?

    PubMed

    Rocha, José C; Passalia, Felipe; Matos, Felipe D; Maserati, Marc P; Alves, Mayra F; Almeida, Tamie G de; Cardoso, Bruna L; Basso, Andrea C; Nogueira, Marcelo F G

    2016-08-01

    Morphological embryo classification is of great importance for many laboratory techniques, from basic research to the ones applied to assisted reproductive technology. However, the standard classification method for both human and cattle embryos, is based on quality parameters that reflect the overall morphological quality of the embryo in cattle, or the quality of the individual embryonic structures, more relevant in human embryo classification. This assessment method is biased by the subjectivity of the evaluator and even though several guidelines exist to standardize the classification, it is not a method capable of giving reliable and trustworthy results. Latest approaches for the improvement of quality assessment include the use of data from cellular metabolism, a new morphological grading system, development kinetics and cleavage symmetry, embryo cell biopsy followed by pre-implantation genetic diagnosis, zona pellucida birefringence, ion release by the embryo cells and so forth. Nowadays there exists a great need for evaluation methods that are practical and non-invasive while being accurate and objective. A method along these lines would be of great importance to embryo evaluation by embryologists, clinicians and other professionals who work with assisted reproductive technology. Several techniques shows promising results in this sense, one being the use of digital images of the embryo as basis for features extraction and classification by means of artificial intelligence techniques (as genetic algorithms and artificial neural networks). This process has the potential to become an accurate and objective standard for embryo quality assessment.

  17. Methods for assessing the quality of mammalian embryos: How far we are from the gold standard?

    PubMed Central

    Rocha, José C.; Passalia, Felipe; Matos, Felipe D.; Maserati Jr, Marc P.; Alves, Mayra F.; de Almeida, Tamie G.; Cardoso, Bruna L.; Basso, Andrea C.; Nogueira, Marcelo F. G.

    2016-01-01

    Morphological embryo classification is of great importance for many laboratory techniques, from basic research to the ones applied to assisted reproductive technology. However, the standard classification method for both human and cattle embryos, is based on quality parameters that reflect the overall morphological quality of the embryo in cattle, or the quality of the individual embryonic structures, more relevant in human embryo classification. This assessment method is biased by the subjectivity of the evaluator and even though several guidelines exist to standardize the classification, it is not a method capable of giving reliable and trustworthy results. Latest approaches for the improvement of quality assessment include the use of data from cellular metabolism, a new morphological grading system, development kinetics and cleavage symmetry, embryo cell biopsy followed by pre-implantation genetic diagnosis, zona pellucida birefringence, ion release by the embryo cells and so forth. Nowadays there exists a great need for evaluation methods that are practical and non-invasive while being accurate and objective. A method along these lines would be of great importance to embryo evaluation by embryologists, clinicians and other professionals who work with assisted reproductive technology. Several techniques shows promising results in this sense, one being the use of digital images of the embryo as basis for features extraction and classification by means of artificial intelligence techniques (as genetic algorithms and artificial neural networks). This process has the potential to become an accurate and objective standard for embryo quality assessment. PMID:27584609

  18. [Method for the quality assessment of data collection processes in epidemiological studies].

    PubMed

    Schöne, G; Damerow, S; Hölling, H; Houben, R; Gabrys, L

    2017-10-01

    For a quantitative evaluation of primary data collection processes in epidemiological surveys based on accompaniments and observations (in the field), there is no description of test criteria and methodologies in relevant literature and thus no known application in practice. Therefore, methods need to be developed and existing procedures adapted. The aim was to identify quality-relevant developments within quality dimensions by means of inspection points (quality indicators) during the process of data collection. As a result we seek to implement and establish a methodology for the assessment of overall survey quality supplementary to standardized data analyses. Monitors detect deviations from standard primary data collection during site visits by applying standardized checklists. Quantitative results - overall and for each dimension - are obtained by numerical calculation of quality indicators. Score results are categorized and color coded. This visual prioritization indicates necessity for intervention. The results obtained give clues regarding the current quality of data collection. This allows for the identification of such sections where interventions for quality improvement are needed. In addition, process quality development can be shown over time on an intercomparable basis. This methodology for the evaluation of data collection quality can identify deviations from norms, focalize quality analyses and help trace causes for significant deviations.

  19. [Application of entropy-weight TOPSIS model in synthetical quality evaluation of Angelica sinensis growing in Gansu Province].

    PubMed

    Gu, Zhi-rong; Wang, Ya-li; Sun, Yu-jing; Dind, Jun-xia

    2014-09-01

    To investigate the establishment and application methods of entropy-weight TOPSIS model in synthetical quality evaluation of traditional Chinese medicine with Angelica sinensis growing in Gansu Province as an example. The contents of ferulic acid, 3-butylphthalide, Z-butylidenephthalide, Z-ligustilide, linolic acid, volatile oil, and ethanol soluble extractive were used as an evaluation index set. The weights of each evaluation index were determined by information entropy method. The entropyweight TOPSIS model was established to synthetically evaluate the quality of Angelica sinensis growing in Gansu Province by Euclid closeness degree. The results based on established model were in line with the daodi meaning and the knowledge of clinical experience. The established model was simple in calculation, objective, reliable, and can be applied to synthetical quality evaluation of traditional Chinese medicine.

  20. Colorimetric-Solid Phase Extraction Technology for Water Quality Monitoring: Evaluation of C-SPE and Debubbling Methods in Microgravity

    NASA Technical Reports Server (NTRS)

    Hazen-Bosveld, April; Lipert, Robert J.; Nordling, John; Shih, Chien-Ju; Siperko, Lorraine; Porter, Marc D.; Gazda, Daniel B.; Rutz, Jeff A.; Straub, John E.; Schultz, John R.; hide

    2007-01-01

    Colorimetric-solid phase extraction (C-SPE) is being developed as a method for in-flight monitoring of spacecraft water quality. C-SPE is based on measuring the change in the diffuse reflectance spectrum of indicator disks following exposure to a water sample. Previous microgravity testing has shown that air bubbles suspended in water samples can cause uncertainty in the volume of liquid passed through the disks, leading to errors in the determination of water quality parameter concentrations. We report here the results of a recent series of C-9 microgravity experiments designed to evaluate manual manipulation as a means to collect bubble-free water samples of specified volumes from water sample bags containing up to 47% air. The effectiveness of manual manipulation was verified by comparing the results from C-SPE analyses of silver(I) and iodine performed in-flight using samples collected and debubbled in microgravity to those performed on-ground using bubble-free samples. The ground and flight results showed excellent agreement, demonstrating that manual manipulation is an effective means for collecting bubble-free water samples in microgravity.

  1. Synthesis method from low-coherence digital holograms for improvement of image quality in holographic display.

    PubMed

    Mori, Yutaka; Nomura, Takanori

    2013-06-01

    In holographic displays, it is undesirable to observe the speckle noises with the reconstructed images. A method for improvement of reconstructed image quality by synthesizing low-coherence digital holograms is proposed. It is possible to obtain speckleless reconstruction of holograms due to low-coherence digital holography. An image sensor records low-coherence digital holograms, and the holograms are synthesized by computational calculation. Two approaches, the threshold-processing and the picking-a-peak methods, are proposed in order to reduce random noise of low-coherence digital holograms. The reconstructed image quality by the proposed methods is compared with the case of high-coherence digital holography. Quantitative evaluation is given to confirm the proposed methods. In addition, the visual evaluation by 15 people is also shown.

  2. An Analytical Hierarchy Process Model for the Evaluation of College Experimental Teaching Quality

    ERIC Educational Resources Information Center

    Yin, Qingli

    2013-01-01

    Taking into account the characteristics of college experimental teaching, through investigaton and analysis, evaluation indices and an Analytical Hierarchy Process (AHP) model of experimental teaching quality have been established following the analytical hierarchy process method, and the evaluation indices have been given reasonable weights. An…

  3. An Underwater Color Image Quality Evaluation Metric.

    PubMed

    Yang, Miao; Sowmya, Arcot

    2015-12-01

    Quality evaluation of underwater images is a key goal of underwater video image retrieval and intelligent processing. To date, no metric has been proposed for underwater color image quality evaluation (UCIQE). The special absorption and scattering characteristics of the water medium do not allow direct application of natural color image quality metrics especially to different underwater environments. In this paper, subjective testing for underwater image quality has been organized. The statistical distribution of the underwater image pixels in the CIELab color space related to subjective evaluation indicates the sharpness and colorful factors correlate well with subjective image quality perception. Based on these, a new UCIQE metric, which is a linear combination of chroma, saturation, and contrast, is proposed to quantify the non-uniform color cast, blurring, and low-contrast that characterize underwater engineering and monitoring images. Experiments are conducted to illustrate the performance of the proposed UCIQE metric and its capability to measure the underwater image enhancement results. They show that the proposed metric has comparable performance to the leading natural color image quality metrics and the underwater grayscale image quality metrics available in the literature, and can predict with higher accuracy the relative amount of degradation with similar image content in underwater environments. Importantly, UCIQE is a simple and fast solution for real-time underwater video processing. The effectiveness of the presented measure is also demonstrated by subjective evaluation. The results show better correlation between the UCIQE and the subjective mean opinion score.

  4. Robust sleep quality quantification method for a personal handheld device.

    PubMed

    Shin, Hangsik; Choi, Byunghun; Kim, Doyoon; Cho, Jaegeol

    2014-06-01

    The purpose of this study was to develop and validate a novel method for sleep quality quantification using personal handheld devices. The proposed method used 3- or 6-axes signals, including acceleration and angular velocity, obtained from built-in sensors in a smartphone and applied a real-time wavelet denoising technique to minimize the nonstationary noise. Sleep or wake status was decided on each axis, and the totals were finally summed to calculate sleep efficiency (SE), regarded as sleep quality in general. The sleep experiment was carried out for performance evaluation of the proposed method, and 14 subjects participated. An experimental protocol was designed for comparative analysis. The activity during sleep was recorded not only by the proposed method but also by well-known commercial applications simultaneously; moreover, activity was recorded on different mattresses and locations to verify the reliability in practical use. Every calculated SE was compared with the SE of a clinically certified medical device, the Philips (Amsterdam, The Netherlands) Actiwatch. In these experiments, the proposed method proved its reliability in quantifying sleep quality. Compared with the Actiwatch, accuracy and average bias error of SE calculated by the proposed method were 96.50% and -1.91%, respectively. The proposed method was vastly superior to other comparative applications with at least 11.41% in average accuracy and at least 6.10% in average bias; average accuracy and average absolute bias error of comparative applications were 76.33% and 17.52%, respectively.

  5. A comparison of indexing methods to evaluate quality of soils subjected to different erosion: the role of soil microbiological properties.

    NASA Astrophysics Data System (ADS)

    Romaniuk, Romina; Lidia, Giuffre; Alejandro, Costantini; Norberto, Bartoloni; Paolo, Nannipieri

    2010-05-01

    Soil quality assessment is needed to evaluate the soil conditions and sustainability of soil and crop management properties, and thus requires a systematic approach to select and interpret soil properties to be used as indicators. The aim of this work was to evaluate and compare different indexing methods to assess quality of an undisturbed grassland soil (UN), a degraded pasture soil (GL) and a no tilled soil (NT) with four different A horizon depths (25, 23, 19 and 14 cm) reflecting a diverse erosion. Twenty four soil properties were measured from 0 to10 (1) and 10 to 20 cm. (2) and a minimum data set was chosen by multivariate principal component analysis (PCA) considering all measured soil properties together (A), or according to their classification in physical, chemical or microbiological (B) properties. The measured soil properties involved either inexpensive or not laborious standard protocols, to be used in routine laboratory analysis (simple soil quality index - SSQI), or a more laborious, time consuming and expensive protocols to determine microbial diversity and microbial functionality by methyl ester fatty acids (PLFA) and catabolic response profiles (CRP), respectively (complex soil quality index - CSQI). The selected properties were linearly normalized and integrated by the weight additive method to calculate SSQI A, SSQI B, CSQI A and CSQI B indices. Two microbiological soil quality indices (MSQI) were also calculated: the MSQI 1 only considered microbiological properties according to the procedure used for calculating SQI; the MSQI 2 was calculated by considering microbial carbon biomass (MCB), microbial activity (Resp) and functional diversity determined by CPR (E). The soil quality indices were SSQI A = MCB 1 + Particulate Organic Carbon (POC)1 + Mean Weight Diameter (MWD)1; SSQI B = Saturated hydraulic conductivity (K) 1 + Total Organic Carbon (TOC) 1 + MCB 1; CSQI A = MCB 1 + POC 1 + MWD 1; CSQI B = K 1+ TOC 1+ 0.3 * (MCB 1+ i/a +POC 1) + 0

  6. Study protocol of a mixed-methods evaluation of a cluster randomized trial to improve the safety of NSAID and antiplatelet prescribing: data-driven quality improvement in primary care.

    PubMed

    Grant, Aileen; Dreischulte, Tobias; Treweek, Shaun; Guthrie, Bruce

    2012-08-28

    Trials of complex interventions are criticized for being 'black box', so the UK Medical Research Council recommends carrying out a process evaluation to explain the trial findings. We believe it is good practice to pre-specify and publish process evaluation protocols to set standards and minimize bias. Unlike protocols for trials, little guidance or standards exist for the reporting of process evaluations. This paper presents the mixed-method process evaluation protocol of a cluster randomized trial, drawing on a framework designed by the authors. This mixed-method evaluation is based on four research questions and maps data collection to a logic model of how the data-driven quality improvement in primary care (DQIP) intervention is expected to work. Data collection will be predominately by qualitative case studies in eight to ten of the trial practices, focus groups with patients affected by the intervention and quantitative analysis of routine practice data, trial outcome and questionnaire data and data from the DQIP intervention. We believe that pre-specifying the intentions of a process evaluation can help to minimize bias arising from potentially misleading post-hoc analysis. We recognize it is also important to retain flexibility to examine the unexpected and the unintended. From that perspective, a mixed-methods evaluation allows the combination of exploratory and flexible qualitative work, and more pre-specified quantitative analysis, with each method contributing to the design, implementation and interpretation of the other.As well as strengthening the study the authors hope to stimulate discussion among their academic colleagues about publishing protocols for evaluations of randomized trials of complex interventions. DATA-DRIVEN QUALITY IMPROVEMENT IN PRIMARY CARE TRIAL REGISTRATION: ClinicalTrials.gov: NCT01425502.

  7. Colour-Difference Measurement Method for Evaluation of Quality of Electrolessly Deposited Copper on Polymer after Laser-Induced Selective Activation

    PubMed Central

    Gedvilas, Mindaugas; Ratautas, Karolis; Kacar, Elif; Stankevičienė, Ina; Jagminienė, Aldona; Norkus, Eugenijus; Li Pira, Nello; Račiukaitis, Gediminas

    2016-01-01

    In this work a novel colour-difference measurement method for the quality evaluation of copper deposited on a polymer is proposed. Laser-induced selective activation (LISA) was performed onto the surface of the polycarbonate/acrylonitrile butadiene styrene (PC/ABS) polymer by using nanosecond laser irradiation. The laser activated PC/ABS polymer was copper plated by using the electroless copper plating (ECP) procedure. The sheet resistance measured by using a four-point probe technique was found to decrease by the power law with the colour-difference of the sample images after LISA and ECP procedures. The percolation theory of the electrical conductivity of the insulator conductor mixture has been adopted in order to explain the experimental results. The new proposed method was used to determine an optimal set of the laser processing parameters for best plating conditions. PMID:26960432

  8. Laboratory Evaluations of the Enterococcus qPCR Method for Recreational Water Quality Testing: Method Performance and Sources of Uncertainty in Quantitative Measurements

    EPA Science Inventory

    The BEACH Act of 2000 directed the U.S. EPA to establish more expeditious methods for the detection of pathogen indicators in coastal waters, as well as new water quality criteria based on these methods. Progress has been made in developing a quantitative PCR (qPCR) method for en...

  9. Evaluation for the ecological quality status of coastal waters in East China Sea using fuzzy integrated assessment method.

    PubMed

    Wu, H Y; Chen, K L; Chen, Z H; Chen, Q H; Qiu, Y P; Wu, J C; Zhang, J F

    2012-03-01

    This research presented an evaluation for the ecological quality status (EcoQS) of three semi-enclosed coastal areas using fuzzy integrated assessment method (FIAM). With this method, the hierarchy structure was clarified by an index system of 11 indicators selected from biotic elements and physicochemical elements, and the weight vector of index system was calculated with Delphi-Analytic Hierarchy Process (AHP) procedure. Then, the FIAM was used to achieve an EcoQS assessment. As a result of assessment, most of the sampling stations demonstrated a clear gradient in EcoQS, ranging from high to poor status. Among the four statuses, high and good, owning a ratio of 55.9% and 26.5%, respectively, were two dominant statuses for three bays, especially for Sansha Bay and Luoyuan Bay. The assessment results were found consistent with the pressure information and parameters obtained at most stations. In addition, the sources of uncertainty in classification of EcoQS were also discussed. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Evaluation of the Spies™ modalities image quality

    PubMed Central

    Emiliani, Esteban; Talso, Michele; Baghdadi, Mohammed; Barreiro, Aarón; Orosa, Andrea; Serviàn, Pol; Gavrilov, Pavel; Proietti, Silvia; Traxer, Olivier

    2017-01-01

    Introduction The Spies™ system (Karl-Storz®) was introduced into digital ureteroscopy to improve endoscopic vision. To date, there is no data to either indicate which of the Spies modalities is better for improving diagnosis and treatment procedures, nor to compare the modalities in terms of image quality. The aim of this study was to evaluate and compare the image quality of five Spies™ modalities (SM) to the standard white light in an in-vitro model. Materials and Methods Two standardized grids and 3 stones of different composition were recorded in white light and the 5SM (Clara, Chroma, Clara+Chroma), Spectra A and B) using 4 standardized aqueous scenarios. Twelve templates were done in order to simultaneously compare the same objective in the different modalities. Six urologists, five medical students, five urology residents, and five persons not involved with urology evaluated each video on a scale of 1 (very bad) to 5 (very good). Results Comparing white light to SM, subjects scored better the quality of Clara and Clara+Chroma than white light (p=0.0139 and p<0.05) and scored worse Spectra A and B (p=0.0005 and p=0.0023)). When comparing Clara to the other SM, it was ranked equivalent to Clara+Chroma (p=0.67) and obtained a higher rank than Chroma, Spectra A and B (p<0.05, p=0.0001 and p=0.0001). In the multivariate analysis mean scores were higher among urologists. Conclusion In all analyzed scenarios, the subjects ranked Clara and Clara+Chroma as the modalities with better image quality compared to white light. PMID:28338307

  11. Nondestructive evaluation of potential quality of creosote-treated piles removed from service

    Treesearch

    Xiping Wang; Robert J. Ross; John R. Erickson; John W. Forsman; Gary D. McGinnis; Rodney C. De Groot

    2001-01-01

    Stress-wave-based nondestructive evaluation methods were used to evaluate the potential quality and modulus of elasticity (MOE) of wood from creosote-treated Douglas-fir and southern pine piles removed from service. Stress-wave measurements were conducted on each pile section. Stress-wave propagation speeds were obtained to estimate the MOE of the wood. Tests were then...

  12. Evaluating supplier quality performance using analytical hierarchy process

    NASA Astrophysics Data System (ADS)

    Kalimuthu Rajoo, Shanmugam Sundram; Kasim, Maznah Mat; Ahmad, Nazihah

    2013-09-01

    This paper elaborates the importance of evaluating supplier quality performance to an organization. Supplier quality performance evaluation reflects the actual performance of the supplier exhibited at customer's end. It is critical in enabling the organization to determine the area of improvement and thereafter works with supplier to close the gaps. Success of the customer partly depends on supplier's quality performance. Key criteria as quality, cost, delivery, technology support and customer service are categorized as main factors in contributing to supplier's quality performance. 18 suppliers' who were manufacturing automotive application parts evaluated in year 2010 using weight point system. There were few suppliers with common rating which led to common ranking observed by few suppliers'. Analytical Hierarchy Process (AHP), a user friendly decision making tool for complex and multi criteria problems was used to evaluate the supplier's quality performance challenging the weight point system that was used for 18 suppliers'. The consistency ratio was checked for criteria and sub-criteria. Final results of AHP obtained with no overlap ratings, therefore yielded a better decision making methodology as compared to weight point rating system.

  13. Methods for collecting algal samples as part of the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Porter, Stephen D.; Cuffney, Thomas F.; Gurtz, Martin E.; Meador, Michael R.

    1993-01-01

    Benthic algae (periphyton) and phytoplankton communities are characterized in the U.S. Geological Survey's National Water-Quality Assessment Program as part of an integrated physical, chemical, and biological assessment of the Nation's water quality. This multidisciplinary approach provides multiple lines of evidence for evaluating water-quality status and trends, and for refining an understanding of the factors that affect water-quality conditions locally, regionally, and nationally. Water quality can be characterized by evaluating the results of qualitative and quantitative measurements of the algal community. Qualitative periphyton samples are collected to develop of list of taxa present in the sampling reach. Quantitative periphyton samples are collected to measure algal community structure within selected habitats. These samples of benthic algal communities are collected from natural substrates, using the sampling methods that are most appropriate for the habitat conditions. Phytoplankton samples may be collected in large nonwadeable streams and rivers to meet specific program objectives. Estimates of algal biomass (chlorophyll content and ash-free dry mass) also are optional measures that may be useful for interpreting water-quality conditions. A nationally consistent approach provides guidance on site, reach, and habitat selection, as well as information on methods and equipment for qualitative and quantitative sampling. Appropriate quality-assurance and quality-control guidelines are used to maximize the ability to analyze data locally, regionally, and nationally.

  14. Improvement of a stability-indicating method by Quality-by-Design versus Quality-by-Testing: a case of a learning process.

    PubMed

    Hubert, C; Lebrun, P; Houari, S; Ziemons, E; Rozet, E; Hubert, Ph

    2014-01-01

    The understanding of the method is a major concern when developing a stability-indicating method and even more so when dealing with impurity assays from complex matrices. In the presented case study, a Quality-by-Design approach was applied in order to optimize a routinely used method. An analytical issue occurring at the last stage of a long-term stability study involving unexpected impurities perturbing the monitoring of characterized impurities needed to be resolved. A compliant Quality-by-Design (QbD) methodology based on a Design of Experiments (DoE) approach was evaluated within the framework of a Liquid Chromatography (LC) method. This approach allows the investigation of Critical Process Parameters (CPPs), which have an impact on Critical Quality Attributes (CQAs) and, consequently, on LC selectivity. Using polynomial regression response modeling as well as Monte Carlo simulations for error propagation, Design Space (DS) was computed in order to determine robust working conditions for the developed stability-indicating method. This QbD compliant development was conducted in two phases allowing the use of the Design Space knowledge acquired during the first phase to define the experimental domain of the second phase, which constitutes a learning process. The selected working condition was then fully validated using accuracy profiles based on statistical tolerance intervals in order to evaluate the reliability of the results generated by this LC/ESI-MS stability-indicating method. A comparison was made between the traditional Quality-by-Testing (QbT) approach and the QbD strategy, highlighting the benefit of this QbD strategy in the case of an unexpected impurities issue. On this basis, the advantages of a systematic use of the QbD methodology were discussed. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. New method for evaluating high-quality fog protective coatings

    NASA Astrophysics Data System (ADS)

    Czeremuszkin, Grzegorz; Latreche, Mohamed; Mendoza-Suarez, Guillermo

    2011-05-01

    Fogging is commonly observed when humid-warm air contacts the cold surface of a transparent substrate, i.e. eyewear lenses, making the observed image blurred and hazy. To protect from fogging, the lens inner surfaces are protected with Anti-Fog coatings, which render them hydrophilic and induce water vapor condensation as a smooth, thin and invisible film, which uniformly flows down on the lens as the condensation progresses. Coatings differ in protection level, aging kinetics, and susceptibility to contamination. Some perform acceptably in limited conditions, beyond which the condensing water film becomes unstable, nonuniform, and scatters light or shows refractory distortions, both affecting the observed image. Quantifying the performance of Anti-Fog coated lenses is difficult: they may not show classical fogging and the existing testing methods, based on fog detection, are therefore inapplicable. The presented method for evaluating and quantifying AF properties is based on characterizing light scattering on lenses exposed to controlled humidity and temperature. Changes in intensity of laser light scattered at low angles (1, 2 4 and 8 degrees), observed during condensation of water on lenses, provide information on the swelling of Anti-Fog coatings, formation of uniform water film, going from an unstable to a steady state, and on the coalescence of discontinuous films. Real time observations/measurements allow for better understanding of factors controlling fogging and fog preventing phenomena. The method is especially useful in the development of new coatings for military-, sport-, and industrial protective eyewear as well as for medical and automotive applications. It allows for differentiating between coatings showing acceptable, good, and excellent performance.

  16. Ontology Based Quality Evaluation for Spatial Data

    NASA Astrophysics Data System (ADS)

    Yılmaz, C.; Cömert, Ç.

    2015-08-01

    Many institutions will be providing data to the National Spatial Data Infrastructure (NSDI). Current technical background of the NSDI is based on syntactic web services. It is expected that this will be replaced by semantic web services. The quality of the data provided is important in terms of the decision-making process and the accuracy of transactions. Therefore, the data quality needs to be tested. This topic has been neglected in Turkey. Data quality control for NSDI may be done by private or public "data accreditation" institutions. A methodology is required for data quality evaluation. There are studies for data quality including ISO standards, academic studies and software to evaluate spatial data quality. ISO 19157 standard defines the data quality elements. Proprietary software such as, 1Spatial's 1Validate and ESRI's Data Reviewer offers quality evaluation based on their own classification of rules. Commonly, rule based approaches are used for geospatial data quality check. In this study, we look for the technical components to devise and implement a rule based approach with ontologies using free and open source software in semantic web context. Semantic web uses ontologies to deliver well-defined web resources and make them accessible to end-users and processes. We have created an ontology conforming to the geospatial data and defined some sample rules to show how to test data with respect to data quality elements including; attribute, topo-semantic and geometrical consistency using free and open source software. To test data against rules, sample GeoSPARQL queries are created, associated with specifications.

  17. Evaluation of ride quality prediction methods for helicopter interior noise and vibration environments

    NASA Technical Reports Server (NTRS)

    Leatherwood, J. D.; Clevenson, S. A.; Hollenbaugh, D. D.

    1984-01-01

    The results of a simulator study conducted to compare and validate various ride quality prediction methods for use in assessing passenger/crew ride comfort within helicopters are presented. Included are results quantifying 35 helicopter pilots discomfort responses to helicopter interior noise and vibration typical of routine flights, assessment of various ride quality metrics including the NASA ride comfort model, and examination of possible criteria approaches. Results of the study indicated that crew discomfort results from a complex interaction between vibration and interior noise. Overall measures such as weighted or unweighted root-mean-square acceleration level and A-weighted noise level were not good predictors of discomfort. Accurate prediction required a metric incorporating the interactive effects of both noise and vibration. The best metric for predicting crew comfort to the combined noise and vibration environment was the NASA discomfort index.

  18. Evaluation of Environmental Quality Productive Ecosystem Guayas (Ecuador).

    NASA Astrophysics Data System (ADS)

    Pozo, Wilson; Pardo, Francisco; Sanfeliu, Teófilo; Carrera, Gloria; Jordan, Manuel; Bech, Jaume; Roca, Núria

    2015-04-01

    Natural resources are deteriorating very rapidly in the Gulf of Guayaquil and the area of influence in the Guayas Basin due to human activity. Specific problems are generated by the mismanagement of the aquaculture industry affecting the traditional agricultural sectors: rice, banana, sugarcane, cocoa, coffee, and soya also studied, and by human and industrial settlements. The development of industrial activities such as aquaculture (shrimp building for shrimp farming in ponds) and agriculture, have increasingly contributed to the generation of waste, degrading and potentially toxic elements in high concentrations, which can have adverse effects on organisms in the ecosystems, in the health of the population and damage the ecological and environmental balance. The productive Guayas ecosystem, consists of three interrelated ecosystems, the Gulf of Guayaquil, the Guayas River estuary and the Guayas Basin buffer. The objective of this study was to evaluate the environmental quality of the productive Guayas ecosystem (Ecuador), through operational and specific objectives: 1) Draw up the transition coastal zone in the Gulf of Guayaquil, 2) Set temporal spatial variability of soil salinity in wetlands rice, Lower Guayas Basin, 3) evaluate the heavy metals in wetland rice in the Lower Basin of Guayas. The physical and chemical parameters of the soils have been studied. These are indicators of environmental quality. The multivariate statistical method showed the relations of similarities and dissimilarities between variables and parameter studies as stable. Moreover, the boundaries of coastal transition areas, temporal spatial variability of soil salinity and heavy metals in rice cultivation in the Lower Basin of Guayas were researched. The sequential studies included and discussed represent a broad framework of fundamental issues that has been valued as a basic component of the productive Guayas ecosystem. They are determinants of the environmental quality of the Guayas

  19. Evaluation of Internal Brushing on Pinch Weld Quality

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Korinko, P

    2005-12-01

    Post machining operations such as borescope inspection can cause linear indications down the length of the bore of fill stems. Often these indications are removed or obscured using rotary wire brushing. This study evaluated the effect this mechanical operation may have on pinch weld quality when relatively cold welds were made. A total of four stems with two levels of brushing of both Type 304L and 21-6-9 stainless steels were tested. In addition, two each of the Type 304L stems were Nitradd cleaned and the other two were aqueously cleaned; all four 21-6-9 stems were aqueously cleaned. All of themore » brushed stem areas exhibited more surface anomalies based on borescope evaluation. On average, the bond rating was a higher value (worse) for the brushed areas than the unadulterated areas for both Type 304L and 21-6-9 stems. The test method used may have biased the results towards a lesser quality bond for the brushed areas so additional testing is recommended.« less

  20. Comparison of methods for quantitative evaluation of endoscopic distortion

    NASA Astrophysics Data System (ADS)

    Wang, Quanzeng; Castro, Kurt; Desai, Viraj N.; Cheng, Wei-Chung; Pfefer, Joshua

    2015-03-01

    Endoscopy is a well-established paradigm in medical imaging, and emerging endoscopic technologies such as high resolution, capsule and disposable endoscopes promise significant improvements in effectiveness, as well as patient safety and acceptance of endoscopy. However, the field lacks practical standardized test methods to evaluate key optical performance characteristics (OPCs), in particular the geometric distortion caused by fisheye lens effects in clinical endoscopic systems. As a result, it has been difficult to evaluate an endoscope's image quality or assess its changes over time. The goal of this work was to identify optimal techniques for objective, quantitative characterization of distortion that are effective and not burdensome. Specifically, distortion measurements from a commercially available distortion evaluation/correction software package were compared with a custom algorithm based on a local magnification (ML) approach. Measurements were performed using a clinical gastroscope to image square grid targets. Recorded images were analyzed with the ML approach and the commercial software where the results were used to obtain corrected images. Corrected images based on the ML approach and the software were compared. The study showed that the ML method could assess distortion patterns more accurately than the commercial software. Overall, the development of standardized test methods for characterizing distortion and other OPCs will facilitate development, clinical translation, manufacturing quality and assurance of performance during clinical use of endoscopic technologies.

  1. Integrating empowerment evaluation and quality improvement to achieve healthcare improvement outcomes.

    PubMed

    Wandersman, Abraham; Alia, Kassandra Ann; Cook, Brittany; Ramaswamy, Rohit

    2015-10-01

    While the body of evidence-based healthcare interventions grows, the ability of health systems to deliver these interventions effectively and efficiently lags behind. Quality improvement approaches, such as the model for improvement, have demonstrated some success in healthcare but their impact has been lessened by implementation challenges. To help address these challenges, we describe the empowerment evaluation approach that has been developed by programme evaluators and a method for its application (Getting To Outcomes (GTO)). We then describe how GTO can be used to implement healthcare interventions. An illustrative healthcare quality improvement example that compares the model for improvement and the GTO method for reducing hospital admissions through improved diabetes care is described. We conclude with suggestions for integrating GTO and the model for improvement. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  2. A quantitative method to evaluate the donor corneal tissue quality used in a comparative study between two hypothermic preservation media.

    PubMed

    Parekh, Mohit; Salvalaio, Gianni; Ferrari, Stefano; Amoureux, Marie-Claude; Albrecht, Cecile; Fortier, Denis; Ponzin, Diego

    2014-12-01

    To standardize a new evaluation technique for calculating the overall quality (OQ) of the donor cornea and validate it using a comparative study of corneas preserved in Optisol-GS and Cornea Cold®. Thirty pairs of donor corneas were selected for a 4 week in vitro comparative study using masked observers. Physiological parameters like thickness, transparency, viable endothelial cell density (VECD) and morphology were transformed to numerical range (0-4) to obtain the OQ. Microbiological examination was performed using Bactec instrument. Students t test showed statistically better results (p < 0.05) from week 3 for thickness, week 2 for transparency and week 1 for morphology and VECD; statistical significance (p < 0.05) was found for OQ from week 2 for the corneas preserved in Cornea Cold® compared to Optisol-GS. Epithelial quality was similar regardless of the medium. Microbiological examination showed absence of aerobic and anaerobic microorganisms in both media. OQ method is efficient, consistent and easy, now validated for comparative studies. Further refinement is necessary for its use at eye-banks, bio-banks and research or transplantation purposes. Cornea Cold® is a promising hypothermic corneal storage medium with preservation time ≤21 days. This permits higher flexibility, evaluation accuracy, longer duration for surgical preparation and ease of transportation.

  3. Defining and evaluating quality for ambulatory care educational programs.

    PubMed

    Bowen, J L; Stearns, J A; Dohner, C; Blackman, J; Simpson, D

    1997-06-01

    As the training of medical students and residents increasingly moves to ambulatory care settings, clerkship and program directors must find a way to use their limited resources to guide the development and evaluation of the quality of these ambulatory-based learning experiences. To evaluate quality, directors must first define, in operational and measurable terms, what is meant by the term "quality" as it is applied to ambulatory-based education. Using educational theories and the definition of quality used by health care systems, the authors propose an operational definition of quality for guiding the planning, implementation, and evaluation of ambulatory care educational programs. They assert that quality is achieved through the interaction of an optimal learning environment, defined educational goals and positive outcomes, participant satisfaction, and cost-effectiveness. By describing the components of quality along with examples of measurable indicators, the authors provide a foundation for the evaluation and improvement of instructional innovations in ambulatory care education for the benefit of teachers, learners, and patients.

  4. Use of Web Technology and Active Learning Strategies in a Quality Assessment Methods Course.

    ERIC Educational Resources Information Center

    Poirier, Therese I.; O'Neil, Christine K.

    2000-01-01

    The authors describe and evaluate quality assessment methods in a health care course that utilized web technology and various active learning strategies. The course was judged successful by student performance, evaluations and student assessments. The instructors were pleased with the outcomes achieved and the educational pedagogy used for this…

  5. Methodological quality of economic evaluations of new pharmaceuticals in The Netherlands.

    PubMed

    Hoomans, Ties; Severens, Johan L; van der Roer, Nicole; Delwel, Gepke O

    2012-03-01

    In the Netherlands, decisions about the reimbursement of new pharmaceuticals are based on cost effectiveness, as well as therapeutic value and budget impact. Since 1 January 2005, drug manufacturers are formally required to substantiate the cost effectiveness of drugs that have therapeutic added value in comparison with existing ones through pharmacoeconomic evaluations. Dutch guidelines for pharmacoeconomic research provide methods guidance, ensuring consistency in both the evidence and the decision-making process about drug reimbursement. This study reviewed the methodological quality of all 21 formally required pharmacoeconomic evaluations of new pharmaceuticals between 1 January 2005 and 1 October 2008, and verified whether these evaluations complied with pharmacoeconomic guidelines. Data on the quality of the pharmacoeconomic evaluations were extracted from the pharmacoeconomic reports published by the Dutch Health Care Insurance Board (CVZ). The Board's newsletters provided information on the advice to, and reimbursement decisions made by, the Dutch Minister of Health. All data extraction was carried out by two independent reviewers, and descriptive analyses were conducted. The methodological quality was sound in only 8 of the 21 pharmacoeconomic evaluations. In most cases, the perspective of analysis, the comparator drugs, and the reporting of both total and incremental costs and effects were correct. However, drug indication, form (i.e. cost utility/cost effectiveness) and time horizon of the evaluations were frequently flawed. Moreover, the costs and effects of the pharmaceuticals were not always analysed correctly, and modelling studies were often non-transparent. Twelve drugs were reimbursed, and nine were not. The compliance with pharmacoeconomic guidelines in economic evaluations of new pharmaceuticals can be improved. This would improve the methodological quality of the pharmacoeconomic evaluations and ensure consistency in the evidence and the

  6. A quality evaluation methodology of health web-pages for non-professionals.

    PubMed

    Currò, Vincenzo; Buonuomo, Paola Sabrina; Onesimo, Roberta; de Rose, Paola; Vituzzi, Andrea; di Tanna, Gian Luca; D'Atri, Alessandro

    2004-06-01

    The proposal of an evaluation methodology for determining the quality of healthcare web sites for the dissemination of medical information to non-professionals. Three (macro) factors are considered for the quality evaluation: medical contents, accountability of the authors, and usability of the web site. Starting from two results in the literature the problem of whether or not to introduce a weighting function has been investigated. This methodology has been validated on a specialized information content, i.e., sore throats, due to the large interest such a topic enjoys with target users. The World Wide Web was accessed using a meta-search system merging several search engines. A statistical analysis was made to compare the proposed methodology with the obtained ranks of the sample web pages. The statistical analysis confirms that the variables examined (per item and sub factor) show substantially similar ranks and are capable of contributing to the evaluation of the main quality macro factors. A comparison between the aggregation functions in the proposed methodology (non-weighted averages) and the weighting functions, derived from the literature, allowed us to verify the suitability of the method. The proposed methodology suggests a simple approach which can quickly award an overall quality score for medical web sites oriented to non-professionals.

  7. Quality of life at sea in Polish seafarer's evaluation.

    PubMed

    Jeżewska, Maria; Grubman-Nowak, Marta; Moryś, Joanna

    2015-01-01

    Work at sea is highly burdening, hazardous and stressful. Environmental, physical, and psychosociological factors have a great impact on the seafarer's quality of life and work. The research is a part of a broader psychological project performed on people working at sea in Poland during a period of 2011-2014. This report presents the self-evaluation of life quality conducted by a total of 1,700 Polish seafarers who took part in the study. The average age of the group was 45. Following methods were used: WHOQOL-BREF and the "Survey for people working at sea". Polish seafarers gave the highest rates to their social relationships (16.27), then the psychological functioning (15.62), and environment (15.51). The physical domain gave the lowest rates (14.63). The results have shown that quality of life of Polish seafarers is quite high.

  8. A framework for assessing Health Economic Evaluation (HEE) quality appraisal instruments

    PubMed Central

    2012-01-01

    Background Health economic evaluations support the health care decision-making process by providing information on costs and consequences of health interventions. The quality of such studies is assessed by health economic evaluation (HEE) quality appraisal instruments. At present, there is no instrument for measuring and improving the quality of such HEE quality appraisal instruments. Therefore, the objectives of this study are to establish a framework for assessing the quality of HEE quality appraisal instruments to support and improve their quality, and to apply this framework to those HEE quality appraisal instruments which have been subject to more scrutiny than others, in order to test the framework and to demonstrate the shortcomings of existing HEE quality appraisal instruments. Methods To develop the quality assessment framework for HEE quality appraisal instruments, the experiences of using appraisal tools for clinical guidelines are used. Based on a deductive iterative process, clinical guideline appraisal instruments identified through literature search are reviewed, consolidated, and adapted to produce the final quality assessment framework for HEE quality appraisal instruments. Results The final quality assessment framework for HEE quality appraisal instruments consists of 36 items organized within 7 dimensions, each of which captures a specific domain of quality. Applying the quality assessment framework to four existing HEE quality appraisal instruments, it is found that these four quality appraisal instruments are of variable quality. Conclusions The framework described in this study should be regarded as a starting point for appraising the quality of HEE quality appraisal instruments. This framework can be used by HEE quality appraisal instrument producers to support and improve the quality and acceptance of existing and future HEE quality appraisal instruments. By applying this framework, users of HEE quality appraisal instruments can become aware

  9. Design and Testing of a Tool for Evaluating the Quality of Diabetes Consumer-Information Web Sites

    PubMed Central

    Steinwachs, Donald; Rubin, Haya R

    2003-01-01

    Background Most existing tools for measuring the quality of Internet health information focus almost exclusively on structural criteria or other proxies for quality information rather than evaluating actual accuracy and comprehensiveness. Objective This research sought to develop a new performance-measurement tool for evaluating the quality of Internet health information, test the validity and reliability of the tool, and assess the variability in diabetes Web site quality. Methods An objective, systematic tool was developed to evaluate Internet diabetes information based on a quality-of-care measurement framework. The principal investigator developed an abstraction tool and trained an external reviewer on its use. The tool included 7 structural measures and 34 performance measures created by using evidence-based practice guidelines and experts' judgments of accuracy and comprehensiveness. Results Substantial variation existed in all categories, with overall scores following a normal distribution and ranging from 15% to 95% (mean was 50% and median was 51%). Lin's concordance correlation coefficient to assess agreement between raters produced a rho of 0.761 (Pearson's r of 0.769), suggesting moderate to high agreement. The average agreement between raters for the performance measures was 0.80. Conclusions Diabetes Web site quality varies widely. Alpha testing of this new tool suggests that it could become a reliable and valid method for evaluating the quality of Internet health sites. Such an instrument could help lay people distinguish between beneficial and misleading information. PMID:14713658

  10. TBDQ: A Pragmatic Task-Based Method to Data Quality Assessment and Improvement

    PubMed Central

    Vaziri, Reza; Mohsenzadeh, Mehran; Habibi, Jafar

    2016-01-01

    Organizations are increasingly accepting data quality (DQ) as a major key to their success. In order to assess and improve DQ, methods have been devised. Many of these methods attempt to raise DQ by directly manipulating low quality data. Such methods operate reactively and are suitable for organizations with highly developed integrated systems. However, there is a lack of a proactive DQ method for businesses with weak IT infrastructure where data quality is largely affected by tasks that are performed by human agents. This study aims to develop and evaluate a new method for structured data, which is simple and practical so that it can easily be applied to real world situations. The new method detects the potentially risky tasks within a process, and adds new improving tasks to counter them. To achieve continuous improvement, an award system is also developed to help with the better selection of the proposed improving tasks. The task-based DQ method (TBDQ) is most appropriate for small and medium organizations, and simplicity in implementation is one of its most prominent features. TBDQ is case studied in an international trade company. The case study shows that TBDQ is effective in selecting optimal activities for DQ improvement in terms of cost and improvement. PMID:27192547

  11. Classification of the fragrant styles and evaluation of the aromatic quality of flue-cured tobacco leaves by machine-learning methods.

    PubMed

    Gu, Li; Xue, Lichun; Song, Qi; Wang, Fengji; He, Huaqin; Zhang, Zhongyi

    2016-12-01

    During commercial transactions, the quality of flue-cured tobacco leaves must be characterized efficiently, and the evaluation system should be easily transferable across different traders. However, there are over 3000 chemical compounds in flue-cured tobacco leaves; thus, it is impossible to evaluate the quality of flue-cured tobacco leaves using all the chemical compounds. In this paper, we used Support Vector Machine (SVM) algorithm together with 22 chemical compounds selected by ReliefF-Particle Swarm Optimization (R-PSO) to classify the fragrant style of flue-cured tobacco leaves, where the Accuracy (ACC) and Matthews Correlation Coefficient (MCC) were 90.95% and 0.80, respectively. SVM algorithm combined with 19 chemical compounds selected by R-PSO achieved the best assessment performance of the aromatic quality of tobacco leaves, where the PCC and MSE were 0.594 and 0.263, respectively. Finally, we constructed two online tools to classify the fragrant style and evaluate the aromatic quality of flue-cured tobacco leaf samples. These tools can be accessed at http://bioinformatics.fafu.edu.cn/tobacco .

  12. Methods for systematic reviews of health economic evaluations: a systematic review, comparison, and synthesis of method literature.

    PubMed

    Mathes, Tim; Walgenbach, Maren; Antoine, Sunya-Lee; Pieper, Dawid; Eikermann, Michaela

    2014-10-01

    The quality of systematic reviews of health economic evaluations (SR-HE) is often limited because of methodological shortcomings. One reason for this poor quality is that there are no established standards for the preparation of SR-HE. The objective of this study is to compare existing methods and suggest best practices for the preparation of SR-HE. To identify the relevant methodological literature on SR-HE, a systematic literature search was performed in Embase, Medline, the National Health System Economic Evaluation Database, the Health Technology Assessment Database, and the Cochrane methodology register, and webpages of international health technology assessment agencies were searched. The study selection was performed independently by 2 reviewers. Data were extracted by one reviewer and verified by a second reviewer. On the basis of the overlaps in the recommendations for the methods of SR-HE in the included papers, suggestions for best practices for the preparation of SR-HE were developed. Nineteen relevant publications were identified. The recommendations within them often differed. However, for most process steps there was some overlap between recommendations for the methods of preparation. The overlaps were taken as basis on which to develop suggestions for the following process steps of preparation: defining the research question, developing eligibility criteria, conducting a literature search, selecting studies, assessing the methodological study quality, assessing transferability, and synthesizing data. The differences in the proposed recommendations are not always explainable by the focus on certain evaluation types, target audiences, or integration in the decision process. Currently, there seem to be no standard methods for the preparation of SR-HE. The suggestions presented here can contribute to the harmonization of methods for the preparation of SR-HE. © The Author(s) 2014.

  13. Measuring, evaluating and improving hospital quality parameters/dimensions--an integrated healthcare quality approach.

    PubMed

    Zineldin, Mosad; Camgöz-Akdağ, Hatice; Vasicheva, Valiantsina

    2011-01-01

    This paper aims to examine the major factors affecting cumulative summation, to empirically examine the major factors affecting satisfaction and to address the question whether patients in Kazakhstan evaluate healthcare similarly or differently from patients in Egypt and Jordan. A questionnaire, adapted from previous research, was distributed to Kazakhstan inpatients. The questionnaire contained 39 attributes about five newly-developed quality dimensions (5Qs), which were identified to be the most relevant attributes for hospitals. The questionnaire was translated into Russian to increase the response rate and improve data quality. Almost 200 usable questionnaires were returned. Frequency distribution, factor analysis and reliability checks were used to analyze the data. The three biggest concerns for Kazakhstan patients are: infrastructure; atmosphere; and interaction. Hospital staffs concern for patients' needs, parking facilities for visitors, waiting time and food temperature were all common specific attributes, which were perceived as concerns. These were shortcomings in all three countries. Improving health service quality by applying total relationship management and the 5Qs model together with a customer-orientation strategy is recommended. Results can be used by hospital staff to reengineer and redesign creatively their quality management processes and help move towards more effective healthcare quality strategies. Patients in three countries have similar concerns and quality perceptions. The paper describes a new instrument and method. The study assures relevance, validity and reliability, while being explicitly change-oriented. The authors argue that patient satisfaction is a cumulative construct, summing satisfaction as five different qualities (5Qs): object; processes; infrastructure; interaction and atmosphere.

  14. Evaluating an integrated approach to clinical quality improvement: clinical guidelines, quality measurement, and supportive system design.

    PubMed

    Cretin, S; Farley, D O; Dolter, K J; Nicholas, W

    2001-08-01

    Implementing clinical practice guidelines to change patient outcomes presents a challenge. Studies of single interventions focused on changing provider behavior demonstrate modest effects, suggesting that effective guideline implementation requires a multifaceted approach. Traditional biomedical research designs are not well suited to evaluating systems interventions. RAND and the Army Medical Department collaborated to develop and evaluate a system for implementing guidelines and documenting their effects on patient care. The evaluation design blended quality improvement, case study, and epidemiologic methods. A formative evaluation of implementation process and an outcome evaluation of patient impact were combined. Guidelines were implemented in 3 successive demonstrations targeting low back pain, asthma, and diabetes. This paper reports on the first wave of 4 facilities implementing a low back pain guideline. Organizational climate and culture, motivation, leadership commitment, and resources were assessed. Selected indicators of processes and outcomes of care were compared before, during, and after guideline implementation at the demonstration facilities and at comparison facilities. Logistic regression analysis was used to test for guideline effects on patient care. Process evaluation documented varied approaches to quality improvement across sites. Outcome evaluation revealed a significant downward trend in the percentage of acute low back pain patients referred to physical therapy or chiropractic care (10.7% to 7.2%) at demonstration sites and no such trend at control sites. Preliminary results suggest the power of this design to stimulate improvements in guideline implementation while retaining the power to evaluate rigorously effects on patient care.

  15. Revised Methods for Characterizing Stream Habitat in the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Fitzpatrick, Faith A.; Waite, Ian R.; D'Arconte, Patricia J.; Meador, Michael R.; Maupin, Molly A.; Gurtz, Martin E.

    1998-01-01

    Stream habitat is characterized in the U.S. Geological Survey's National Water-Quality Assessment (NAWQA) Program as part of an integrated physical, chemical, and biological assessment of the Nation's water quality. The goal of stream habitat characterization is to relate habitat to other physical, chemical, and biological factors that describe water-quality conditions. To accomplish this goal, environmental settings are described at sites selected for water-quality assessment. In addition, spatial and temporal patterns in habitat are examined at local, regional, and national scales. This habitat protocol contains updated methods for evaluating habitat in NAWQA Study Units. Revisions are based on lessons learned after 6 years of applying the original NAWQA habitat protocol to NAWQA Study Unit ecological surveys. Similar to the original protocol, these revised methods for evaluating stream habitat are based on a spatially hierarchical framework that incorporates habitat data at basin, segment, reach, and microhabitat scales. This framework provides a basis for national consistency in collection techniques while allowing flexibility in habitat assessment within individual Study Units. Procedures are described for collecting habitat data at basin and segment scales; these procedures include use of geographic information system data bases, topographic maps, and aerial photographs. Data collected at the reach scale include channel, bank, and riparian characteristics.

  16. THE ATMOSPHERIC MODEL EVALUATION TOOL (AMET); AIR QUALITY MODULE

    EPA Science Inventory

    This presentation reviews the development of the Atmospheric Model Evaluation Tool (AMET) air quality module. The AMET tool is being developed to aid in the model evaluation. This presentation focuses on the air quality evaluation portion of AMET. Presented are examples of the...

  17. Evaluation of a Standardized Method of Quality Assurance in Mental Health Records: A Pilot Study

    ERIC Educational Resources Information Center

    Bradshaw, Kelsey M.; Donohue, Bradley; Fayeghi, Jasmine; Lee, Tiffany; Wilks, Chelsey R.; Ross, Brendon

    2016-01-01

    The widespread adoption of research-supported treatments by mental health providers has facilitated empirical development of quality assurance (QA) methods. Research in this area has focused on QA systems aimed at assuring the integrity of research-supported treatment implementation, while examination of QA systems to assure appropriate…

  18. Evaluating Journal Quality: Is the H-Index a Better Measure than Impact Factors?

    ERIC Educational Resources Information Center

    Hodge, David R.; Lacasse, Jeffrey R.

    2011-01-01

    Objectives: This study evaluates the utility of a new measure--the h-index--that may provide a more valid approach to evaluating journal quality in the social work profession. Method: H-index values are compared with Thomson ISI 5-year impact factors and expert opinion. Results: As hypothesized, the h-index correlates highly with ISI 5-year impact…

  19. Quality evaluation and control of end cap welds in PHWR fuel elements by ultrasonic examination

    NASA Astrophysics Data System (ADS)

    Choi, M. S.; Yang, M. S.

    1991-02-01

    The current quality control procedure of nuclear fuel end cap weld is mainly dependent on the destructive metallographic examination. A nondestructive examination technique, i.e., ultrasonic examination, has been developed to identify and evaluate weld discontinuities. A few interesting results of the weld quality evaluation by applying the developed ultrasonic examination technique to PHWR fuel welds are presented. In addition, the feasibility of the weld quality control by the ultrasonic examination is discussed. This study shows that the ultrasonic examination is effective and reliable method for detecting abnormal weld contours and weld discontinuities such as micro-fissure, crack, upset split and expulsion, and can be used as a quality control tool for the end cap welding process.

  20. Economic evaluation in patient safety: a literature review of methods.

    PubMed

    de Rezende, Bruna Alves; Or, Zeynep; Com-Ruelle, Laure; Michel, Philippe

    2012-06-01

    Patient safety practices, targeting organisational changes for improving patient safety, are implemented worldwide but their costs are rarely evaluated. This paper provides a review of the methods used in economic evaluation of such practices. International medical and economics databases were searched for peer-reviewed publications on economic evaluations of patient safety between 2000 and 2010 in English and French. This was complemented by a manual search of the reference lists of relevant papers. Grey literature was excluded. Studies were described using a standardised template and assessed independently by two researchers according to six quality criteria. 33 articles were reviewed that were representative of different patient safety domains, data types and evaluation methods. 18 estimated the economic burden of adverse events, 3 measured the costs of patient safety practices and 12 provided complete economic evaluations. Healthcare-associated infections were the most common subject of evaluation, followed by medication-related errors and all types of adverse events. Of these, 10 were selected that had adequately fulfilled one or several key quality criteria for illustration. This review shows that full cost-benefit/utility evaluations are rarely completed as they are resource intensive and often require unavailable data; some overcome these difficulties by performing stochastic modelling and by using secondary sources. Low methodological transparency can be a problem for building evidence from available economic evaluations. Investing in the economic design and reporting of studies with more emphasis on defining study perspectives, data collection and methodological choices could be helpful for strengthening our knowledge base on practices for improving patient safety.

  1. [Seed quality test methods of Paeonia suffruticosa].

    PubMed

    Cao, Ya-Yue; Zhu, Zai-Biao; Guo, Qiao-Sheng; Liu, Li; Wang, Chang-Lin

    2014-11-01

    In order to optimize the testing methods for Paeonia suffruticosa seed quality, and provide basis for establishing seed testing rules and seed quality standard of P. suffruticosa. The seed quality of P. suffruticosa from different producing areas was measured based on the related seed testing regulations. The seed testing methods for quality items of P. suffruticosa was established preliminarily. The samples weight of P. suffruticosa was at least 7 000 g for purity analysis and was at least 700 g for test. The phenotypic observation and size measurement were used for authenticity testing. The 1 000-seed weight was determined by 100-seed method, and the water content was carried out by low temperature drying method (10 hours). After soaking in distilled water for 24 h, the seeds was treated with different temperature stratifications of day and night (25 degrees C/20 degrees C, day/night) in the dark for 60 d. After soaking in the liquor of GA3 300 mg x L(-1) for 24 h, the P. suffruticos seeds were cultured in wet sand at 15 degrees C for 12-60 days for germination testing. Seed viability was tested by TlC method.

  2. Massive integration of diverse protein quality assessment methods to improve template based modeling in CASP11

    PubMed Central

    Cao, Renzhi; Bhattacharya, Debswapna; Adhikari, Badri; Li, Jilong; Cheng, Jianlin

    2015-01-01

    Model evaluation and selection is an important step and a big challenge in template-based protein structure prediction. Individual model quality assessment methods designed for recognizing some specific properties of protein structures often fail to consistently select good models from a model pool because of their limitations. Therefore, combining multiple complimentary quality assessment methods is useful for improving model ranking and consequently tertiary structure prediction. Here, we report the performance and analysis of our human tertiary structure predictor (MULTICOM) based on the massive integration of 14 diverse complementary quality assessment methods that was successfully benchmarked in the 11th Critical Assessment of Techniques of Protein Structure prediction (CASP11). The predictions of MULTICOM for 39 template-based domains were rigorously assessed by six scoring metrics covering global topology of Cα trace, local all-atom fitness, side chain quality, and physical reasonableness of the model. The results show that the massive integration of complementary, diverse single-model and multi-model quality assessment methods can effectively leverage the strength of single-model methods in distinguishing quality variation among similar good models and the advantage of multi-model quality assessment methods of identifying reasonable average-quality models. The overall excellent performance of the MULTICOM predictor demonstrates that integrating a large number of model quality assessment methods in conjunction with model clustering is a useful approach to improve the accuracy, diversity, and consequently robustness of template-based protein structure prediction. PMID:26369671

  3. Systematic Review and Quality Appraisal of Economic Evaluation Publications in Dentistry.

    PubMed

    Tonmukayakul, U; Calache, H; Clark, R; Wasiak, J; Faggion, C M

    2015-10-01

    Economic evaluation (EE) studies have been undertaken in dentistry since the late 20th century because economic data provide additional information to policy makers to develop guidelines and set future direction for oral health services. The objectives of this study were to assess the methodological quality of EEs in oral health. Electronic searching of Ovid MEDLINE, the Cochrane Library, and the NHS Economic Evaluation Database from 1975 to 2013 were undertaken to identify publications that include costs and outcomes in dentistry. Relevant reference lists were also searched for additional studies. Studies were retrieved and reviewed independently for inclusion by 3 authors. Furthermore, to appraise the EE methods, 1 author applied the Drummond 10-item (13-criteria) checklist tool to each study. Of the 114 publications identified, 79 studies were considered full EE and 35 partial. Twenty-eight studies (30%) were published between the years 2011 and 2013. Sixty-four (53%) studies focused on dental caries prevention or treatment. Median appraisal scores calculated for full and partial EE studies were 11 and 9 out of 13, respectively. Quality assessment scores showed that the quality of partial EE studies published after 2000 significantly improved (P = 0.02) compared to those published before 2000. Significant quality improvement was not found in full EE studies. Common methodological limitations were identified: absence of sensitivity analysis, discounting, and insufficient information on how costs and outcomes were measured and valued. EE studies in dentistry increased over the last 40 y in both quantity and quality, but a number of publications failed to satisfy some components of standard EE research methods, such as sensitivity analysis and discounting. © International & American Associations for Dental Research 2015.

  4. ATTRIBUTES OF AESTHETIC QUALITY USED BY TEXTILE CONSERVATORS IN EVALUATING CONSERVATION INTERVENTIONS ON MUSEUM COSTUMES.

    PubMed

    Nilsson, Johanna; Axelsson, Östen

    2015-08-01

    Aesthetic quality is central to textile conservators when evaluating a conservation method. However, the literature on textile conservation chiefly focuses on physical properties, and little is known about what factors determine aesthetic quality according to textile conservators. The latter was explored through two experiments. Experiment 1 explored the underlying attributes of aesthetic quality of textile conservation interventions. Experiment 2 explored the relationships between these attributes and how well they predicted aesthetic quality. Rank-order correlation analyses revealed two latent factors called Coherence and Completeness. Ordinal regression analysis revealed that Coherence was the most important predictor of aesthetic quality. This means that a successful conservation intervention is visually well-integrated with the textile item in terms of the material and method.

  5. Evaluating the effectiveness of air quality interventions.

    PubMed

    van Erp, Annemoon M M; O'Keefe, Robert; Cohen, Aaron J; Warren, Jane

    2008-01-01

    Evaluating the extent to which air quality regulations improve public health--sometimes referred to as accountability--is part of an emerging effort to assess the effectiveness of environmental regulatory policies. Air quality has improved substantially in the United States and Western Europe in recent decades, with far less visible pollution and decreasing concentrations of several major pollutants. In large part, these gains were achieved through increasingly stringent air quality regulations. The costs associated with compliance and, importantly, the need to ensure that the regulations are achieving the intended public health benefits underscore the importance of accountability research. To date, accountability research has emphasized measuring the effects of actions already taken to improve air quality. Such research may also contribute to estimating the burden of disease that might be avoided in the future if certain actions are taken. The Health Effects Institute (HEI) currently funds eight ongoing studies on accountability, which cover near-term interventions to improve air quality including (1) a ban on the sale of coal, (2) replacing old wood stoves with cleaner ones, (3) decreasing sulfur content in fuel, (4) measures to reduce traffic, and (5) longer term, wide-ranging actions or events (such as complex changes associated with the reunification of Germany). HEI is also funding the development of methods and research to assess regulations that are implemented incrementally over extended periods of time, such as Title IV of the 1990 Clean Air Act Amendments, which reduces sulfur dioxide emissions from power plants in the eastern United States.

  6. Are the defined substrate-based methods adequate to determine the microbiological quality of natural recreational waters?

    PubMed

    Valente, Marta Sofia; Pedro, Paulo; Alonso, M Carmen; Borrego, Juan J; Dionísio, Lídia

    2010-03-01

    Monitoring the microbiological quality of water used for recreational activities is very important to human public health. Although the sanitary quality of recreational marine waters could be evaluated by standard methods, they are time-consuming and need confirmation. For these reasons, faster and more sensitive methods, such as the defined substrate-based technology, have been developed. In the present work, we have compared the standard method of membrane filtration using Tergitol-TTC agar for total coliforms and Escherichia coli, and Slanetz and Bartley agar for enterococci, and the IDEXX defined substrate technology for these faecal pollution indicators to determine the microbiological quality of natural recreational waters. ISO 17994:2004 standard was used to compare these methods. The IDEXX for total coliforms and E. coli, Colilert, showed higher values than those obtained by the standard method. Enterolert test, for the enumeration of enterococci, showed lower values when compared with the standard method. It may be concluded that more studies to evaluate the precision and accuracy of the rapid tests are required in order to apply them for routine monitoring of marine and freshwater recreational bathing areas. The main advantages of these methods are that they are more specific, feasible and simpler than the standard methodology.

  7. Quality evaluation of extracted ion chromatograms and chromatographic peaks in liquid chromatography/mass spectrometry-based metabolomics data.

    PubMed

    Zhang, Wenchao; Zhao, Patrick X

    2014-01-01

    Extracted ion chromatogram (EIC) extraction and chromatographic peak detection are two important processing procedures in liquid chromatography/mass spectrometry (LC/MS)-based metabolomics data analysis. Most commonly, the LC/MS technique employs electrospray ionization as the ionization method. The EICs from LC/MS data are often noisy and contain high background signals. Furthermore, the chromatographic peak quality varies with respect to its location in the chromatogram and most peaks have zigzag shapes. Therefore, there is a critical need to develop effective metrics for quality evaluation of EICs and chromatographic peaks in LC/MS based metabolomics data analysis. We investigated a comprehensive set of potential quality evaluation metrics for extracted EICs and detected chromatographic peaks. Specifically, for EIC quality evaluation, we analyzed the mass chromatographic quality index (MCQ index) and propose a novel quality evaluation metric, the EIC-related global zigzag index, which is based on an EIC's first order derivatives. For chromatographic peak quality evaluation, we analyzed and compared six metrics: sharpness, Gaussian similarity, signal-to-noise ratio, peak significance level, triangle peak area similarity ratio and the local peak-related local zigzag index. Although the MCQ index is suited for selecting and aligning analyte components, it cannot fairly evaluate EICs with high background signals or those containing only a single peak. Our proposed EIC related global zigzag index is robust enough to evaluate EIC qualities in both scenarios. Of the six peak quality evaluation metrics, the sharpness, peak significance level, and zigzag index outperform the others due to the zigzag nature of LC/MS chromatographic peaks. Furthermore, using several peak quality metrics in combination is more efficient than individual metrics in peak quality evaluation.

  8. 5 CFR 531.508 - Evaluation of quality step increase authority.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Evaluation of quality step increase... REGULATIONS PAY UNDER THE GENERAL SCHEDULE Quality Step Increases § 531.508 Evaluation of quality step... grant quality step increases. The agency shall take any corrective action required by the Office. [60 FR...

  9. Criteria for evaluating programme theory diagrams in quality improvement initiatives: a structured method for appraisal.

    PubMed

    Issen, Laurel; Woodcock, Thomas; McNicholas, Christopher; Lennox, Laura; Reed, Julie E

    2018-04-09

    Despite criticisms that many quality improvement (QI) initiatives fail due to incomplete programme theory, there is no defined way to evaluate how programme theory has been articulated. The objective of this research was to develop, and assess the usability and reliability of scoring criteria to evaluate programme theory diagrams. Criteria development was informed by published literature and QI experts. Inter-rater reliability was tested between two evaluators. About 63 programme theory diagrams (42 driver diagrams and 21 action-effect diagrams) were reviewed to establish whether the criteria could support comparative analysis of different approaches to constructing diagrams. Components of the scoring criteria include: assessment of overall aim, logical overview, clarity of components, cause-effect relationships, evidence and measurement. Independent reviewers had 78% inter-rater reliability. Scoring enabled direct comparison of different approaches to developing programme theory; action-effect diagrams were found to have had a statistically significant but moderate improvement in programme theory quality over driver diagrams; no significant differences were observed based on the setting in which driver diagrams were developed. The scoring criteria summarise the necessary components of programme theory that are thought to contribute to successful QI projects. The viability of the scoring criteria for practical application was demonstrated. Future uses include assessment of individual programme theory diagrams and comparison of different approaches (e.g. methodological, teaching or other QI support) to produce programme theory. The criteria can be used as a tool to guide the production of better programme theory diagrams, and also highlights where additional support for QI teams could be needed.

  10. New patient-controlled abdominal compression method in radiography: radiation dose and image quality.

    PubMed

    Piippo-Huotari, Oili; Norrman, Eva; Anderzén-Carlsson, Agneta; Geijer, Håkan

    2018-05-01

    The radiation dose for patients can be reduced with many methods and one way is to use abdominal compression. In this study, the radiation dose and image quality for a new patient-controlled compression device were compared with conventional compression and compression in the prone position . To compare radiation dose and image quality of patient-controlled compression compared with conventional and prone compression in general radiography. An experimental design with quantitative approach. After obtaining the approval of the ethics committee, a consecutive sample of 48 patients was examined with the standard clinical urography protocol. The radiation doses were measured as dose-area product and analyzed with a paired t-test. The image quality was evaluated by visual grading analysis. Four radiologists evaluated each image individually by scoring nine criteria modified from the European quality criteria for diagnostic radiographic images. There was no significant difference in radiation dose or image quality between conventional and patient-controlled compression. Prone position resulted in both higher dose and inferior image quality. Patient-controlled compression gave similar dose levels as conventional compression and lower than prone compression. Image quality was similar with both patient-controlled and conventional compression and was judged to be better than in the prone position.

  11. Quality Evaluation of Agricultural Distillates Using an Electronic Nose

    PubMed Central

    Dymerski, Tomasz; Gębicki, Jacek; Wardencki, Waldemar; Namieśnik, Jacek

    2013-01-01

    The paper presents the application of an electronic nose instrument to fast evaluation of agricultural distillates differing in quality. The investigations were carried out using a prototype of electronic nose equipped with a set of six semiconductor sensors by FIGARO Co., an electronic circuit converting signal into digital form and a set of thermostats able to provide gradient temperature characteristics to a gas mixture. A volatile fraction of the agricultural distillate samples differing in quality was obtained by barbotage. Interpretation of the results involved three data analysis techniques: principal component analysis, single-linkage cluster analysis and cluster analysis with spheres method. The investigations prove the usefulness of the presented technique in the quality control of agricultural distillates. Optimum measurements conditions were also defined, including volumetric flow rate of carrier gas (15 L/h), thermostat temperature during the barbotage process (15 °C) and time of sensor signal acquisition from the onset of the barbotage process (60 s). PMID:24287525

  12. The Explication of Quality Standards in Self-Evaluation

    ERIC Educational Resources Information Center

    Bronkhorst, Larike H.; Baartman, Liesbeth K. J.; Stokking, Karel M.

    2012-01-01

    Education aiming at students' competence development asks for new assessment methods. The quality of these methods needs to be assured using adapted quality criteria and accompanying standards. As such standards are not widely available, this study sets out to examine what level of compliance with quality criteria stakeholders consider…

  13. Recommendations for a mixed methods approach to evaluating the patient-centered medical home.

    PubMed

    Goldman, Roberta E; Parker, Donna R; Brown, Joanna; Walker, Judith; Eaton, Charles B; Borkan, Jeffrey M

    2015-03-01

    There is a strong push in the United States to evaluate whether the patient-centered medical home (PCMH) model produces desired results. The explanatory and contextually based questions of how and why PCMH succeeds in different practice settings are often neglected. We report the development of a comprehensive, mixed qualitative-quantitative evaluation set for researchers, policy makers, and clinician groups. To develop an evaluation set, the Brown Primary Care Transformation Initiative convened a multidisciplinary group of PCMH experts, reviewed the PCMH literature and evaluation strategies, developed key domains for evaluation, and selected or created methods and measures for inclusion. The measures and methods in the evaluation set (survey instruments, PCMH meta-measures, patient outcomes, quality measures, qualitative interviews, participant observation, and process evaluation) are meant to be used together. PCMH evaluation must be sufficiently comprehensive to assess and explain both the context of transformation in different primary care practices and the experiences of diverse stakeholders. In addition to commonly assessed patient outcomes, quality, and cost, it is critical to include PCMH components integral to practice culture transformation: patient and family centeredness, authentic patient activation, mutual trust among practice employees and patients, and transparency, joy, and collaboration in delivering and receiving care in a changing environment. This evaluation set offers a comprehensive methodology to enable understanding of how PCMH transformation occurs in different practice settings. This approach can foster insights about how transformation affects critical outcomes to achieve meaningful, patient-centered, high-quality, and cost-effective sustainable change among diverse primary care practices. © 2015 Annals of Family Medicine, Inc.

  14. Quality evaluation of poultry carcasses

    USDA-ARS?s Scientific Manuscript database

    The USDA Food Safety Inspection Service (FSIS) has been mandated to organoleptically inspect poultry carcasses online at processing plants. For poultry quality and safety evaluation, the development of accurate and reliable instruments for online detection of unwholesomeness such as septicemia, cada...

  15. Headache service quality: evaluation of quality indicators in 14 specialist-care centres.

    PubMed

    Schramm, Sara; Uluduz, Derya; Gouveia, Raquel Gil; Jensen, Rigmor; Siva, Aksel; Uygunoglu, Ugur; Gvantsa, Giorgadze; Mania, Maka; Braschinsky, Mark; Filatova, Elena; Latysheva, Nina; Osipova, Vera; Skorobogatykh, Kirill; Azimova, Julia; Straube, Andreas; Eren, Ozan Emre; Martelletti, Paolo; De Angelis, Valerio; Negro, Andrea; Linde, Mattias; Hagen, Knut; Radojicic, Aleksandra; Zidverc-Trajkovic, Jasna; Podgorac, Ana; Paemeleire, Koen; De Pue, Annelien; Lampl, Christian; Steiner, Timothy J; Katsarava, Zaza

    2016-12-01

    The study was a collaboration between Lifting The Burden (LTB) and the European Headache Federation (EHF). Its aim was to evaluate the implementation of quality indicators for headache care Europe-wide in specialist headache centres (level-3 according to the EHF/LTB standard). Employing previously-developed instruments in 14 such centres, we made enquiries, in each, of health-care providers (doctors, nurses, psychologists, physiotherapists) and 50 patients, and analysed the medical records of 50 other patients. Enquiries were in 9 domains: diagnostic accuracy, individualized management, referral pathways, patient's education and reassurance, convenience and comfort, patient's satisfaction, equity and efficiency of the headache care, outcome assessment and safety. Our study showed that highly experienced headache centres treated their patients in general very well. The centres were content with their work and their patients were content with their treatment. Including disability and quality-of-life evaluations in clinical assessments, and protocols regarding safety, proved problematic: better standards for these are needed. Some centres had problems with follow-up: many specialised centres operated in one-touch systems, without possibility of controlling long-term management or the success of treatments dependent on this. This first Europe-wide quality study showed that the quality indicators were workable in specialist care. They demonstrated common trends, producing evidence of what is majority practice. They also uncovered deficits that might be remedied in order to improve quality. They offer the means of setting benchmarks against which service quality may be judged. The next step is to take the evaluation process into non-specialist care (EHF/LTB levels 1 and 2).

  16. Quality evaluation of Persian nutrition and diet therapy websites

    PubMed Central

    Gholizadeh, Zahra; Papi, Ahmad; Ashrafi-rizi, Hasan; Shahrzadi, Leila; Hasanzadeh, Akbar

    2017-01-01

    INTRODUCTION: Nowadays websites are among the most important information sources used by most people. With the spread of websites, especially those related to health issues, the number of their visitors also increases, more than half of which are about nutritional information. Therefore, quality analysis of nutrition and diet therapy websites is of outmost importance. This study aims to evaluate the quality of Persian nutrition and diet therapy websites. METHODS: The current work is a survey study and uses an applied study method. The statistical population consists of 51 Persian websites about nutrition and diet therapy and census method was used in order to study them. Data gathering was done using a checklist and with direct visit to each website. Descriptive and analytical statistics were used to analyse the gathered data with the help of SPSS 21 software. RESULTS: Findings showed that content (66.7%), organization (82.4%), user friendly interfaces (52.9%) and total quality (70.6%) of most websites had a mediocre score while the design score for most of the websites (70.6%) was acceptable also organizational websites had better design, organization and quality compared to private websites. The three websites with the highest general quality score were the websites of “Novel Diet Therapy,” “Behsite” and “Dr. BehdadiPour” (jointly) and “Dr. Kermani” respectively. Also in the dimension of content the factors of goal, relevance and credibility, in the dimension of design the factors of color, text and sound, pictures and videos, in the dimension of organization the factors of stability and indexing and in the dimension of user friendliness the factors of confidentiality, credibility and personalization had the highest scores. CONCLUSION: The results showed that the design score was higher than other scores. Also the general quality score of the websites was mediocre and was not desirable. Also websites didn’t have suitable scores in every factor

  17. Evaluating the quality of a cell counting measurement process via a dilution series experimental design.

    PubMed

    Sarkar, Sumona; Lund, Steven P; Vyzasatya, Ravi; Vanguri, Padmavathy; Elliott, John T; Plant, Anne L; Lin-Gibson, Sheng

    2017-12-01

    Cell counting measurements are critical in the research, development and manufacturing of cell-based products, yet determining cell quantity with accuracy and precision remains a challenge. Validating and evaluating a cell counting measurement process can be difficult because of the lack of appropriate reference material. Here we describe an experimental design and statistical analysis approach to evaluate the quality of a cell counting measurement process in the absence of appropriate reference materials or reference methods. The experimental design is based on a dilution series study with replicate samples and observations as well as measurement process controls. The statistical analysis evaluates the precision and proportionality of the cell counting measurement process and can be used to compare the quality of two or more counting methods. As an illustration of this approach, cell counting measurement processes (automated and manual methods) were compared for a human mesenchymal stromal cell (hMSC) preparation. For the hMSC preparation investigated, results indicated that the automated method performed better than the manual counting methods in terms of precision and proportionality. By conducting well controlled dilution series experimental designs coupled with appropriate statistical analysis, quantitative indicators of repeatability and proportionality can be calculated to provide an assessment of cell counting measurement quality. This approach does not rely on the use of a reference material or comparison to "gold standard" methods known to have limited assurance of accuracy and precision. The approach presented here may help the selection, optimization, and/or validation of a cell counting measurement process. Published by Elsevier Inc.

  18. Image aesthetic quality evaluation using convolution neural network embedded learning

    NASA Astrophysics Data System (ADS)

    Li, Yu-xin; Pu, Yuan-yuan; Xu, Dan; Qian, Wen-hua; Wang, Li-peng

    2017-11-01

    A way of embedded learning convolution neural network (ELCNN) based on the image content is proposed to evaluate the image aesthetic quality in this paper. Our approach can not only solve the problem of small-scale data but also score the image aesthetic quality. First, we chose Alexnet and VGG_S to compare for confirming which is more suitable for this image aesthetic quality evaluation task. Second, to further boost the image aesthetic quality classification performance, we employ the image content to train aesthetic quality classification models. But the training samples become smaller and only using once fine-tuning cannot make full use of the small-scale data set. Third, to solve the problem in second step, a way of using twice fine-tuning continually based on the aesthetic quality label and content label respective is proposed, the classification probability of the trained CNN models is used to evaluate the image aesthetic quality. The experiments are carried on the small-scale data set of Photo Quality. The experiment results show that the classification accuracy rates of our approach are higher than the existing image aesthetic quality evaluation approaches.

  19. Quality evaluation of extracted ion chromatograms and chromatographic peaks in liquid chromatography/mass spectrometry-based metabolomics data

    PubMed Central

    2014-01-01

    Background Extracted ion chromatogram (EIC) extraction and chromatographic peak detection are two important processing procedures in liquid chromatography/mass spectrometry (LC/MS)-based metabolomics data analysis. Most commonly, the LC/MS technique employs electrospray ionization as the ionization method. The EICs from LC/MS data are often noisy and contain high background signals. Furthermore, the chromatographic peak quality varies with respect to its location in the chromatogram and most peaks have zigzag shapes. Therefore, there is a critical need to develop effective metrics for quality evaluation of EICs and chromatographic peaks in LC/MS based metabolomics data analysis. Results We investigated a comprehensive set of potential quality evaluation metrics for extracted EICs and detected chromatographic peaks. Specifically, for EIC quality evaluation, we analyzed the mass chromatographic quality index (MCQ index) and propose a novel quality evaluation metric, the EIC-related global zigzag index, which is based on an EIC's first order derivatives. For chromatographic peak quality evaluation, we analyzed and compared six metrics: sharpness, Gaussian similarity, signal-to-noise ratio, peak significance level, triangle peak area similarity ratio and the local peak-related local zigzag index. Conclusions Although the MCQ index is suited for selecting and aligning analyte components, it cannot fairly evaluate EICs with high background signals or those containing only a single peak. Our proposed EIC related global zigzag index is robust enough to evaluate EIC qualities in both scenarios. Of the six peak quality evaluation metrics, the sharpness, peak significance level, and zigzag index outperform the others due to the zigzag nature of LC/MS chromatographic peaks. Furthermore, using several peak quality metrics in combination is more efficient than individual metrics in peak quality evaluation. PMID:25350128

  20. Massive integration of diverse protein quality assessment methods to improve template based modeling in CASP11.

    PubMed

    Cao, Renzhi; Bhattacharya, Debswapna; Adhikari, Badri; Li, Jilong; Cheng, Jianlin

    2016-09-01

    Model evaluation and selection is an important step and a big challenge in template-based protein structure prediction. Individual model quality assessment methods designed for recognizing some specific properties of protein structures often fail to consistently select good models from a model pool because of their limitations. Therefore, combining multiple complimentary quality assessment methods is useful for improving model ranking and consequently tertiary structure prediction. Here, we report the performance and analysis of our human tertiary structure predictor (MULTICOM) based on the massive integration of 14 diverse complementary quality assessment methods that was successfully benchmarked in the 11th Critical Assessment of Techniques of Protein Structure prediction (CASP11). The predictions of MULTICOM for 39 template-based domains were rigorously assessed by six scoring metrics covering global topology of Cα trace, local all-atom fitness, side chain quality, and physical reasonableness of the model. The results show that the massive integration of complementary, diverse single-model and multi-model quality assessment methods can effectively leverage the strength of single-model methods in distinguishing quality variation among similar good models and the advantage of multi-model quality assessment methods of identifying reasonable average-quality models. The overall excellent performance of the MULTICOM predictor demonstrates that integrating a large number of model quality assessment methods in conjunction with model clustering is a useful approach to improve the accuracy, diversity, and consequently robustness of template-based protein structure prediction. Proteins 2016; 84(Suppl 1):247-259. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  1. Near-infrared fluorescence image quality test methods for standardized performance evaluation

    NASA Astrophysics Data System (ADS)

    Kanniyappan, Udayakumar; Wang, Bohan; Yang, Charles; Ghassemi, Pejhman; Wang, Quanzeng; Chen, Yu; Pfefer, Joshua

    2017-03-01

    Near-infrared fluorescence (NIRF) imaging has gained much attention as a clinical method for enhancing visualization of cancers, perfusion and biological structures in surgical applications where a fluorescent dye is monitored by an imaging system. In order to address the emerging need for standardization of this innovative technology, it is necessary to develop and validate test methods suitable for objective, quantitative assessment of device performance. Towards this goal, we develop target-based test methods and investigate best practices for key NIRF imaging system performance characteristics including spatial resolution, depth of field and sensitivity. Characterization of fluorescence properties was performed by generating excitation-emission matrix properties of indocyanine green and quantum dots in biological solutions and matrix materials. A turbid, fluorophore-doped target was used, along with a resolution target for assessing image sharpness. Multi-well plates filled with either liquid or solid targets were generated to explore best practices for evaluating detection sensitivity. Overall, our results demonstrate the utility of objective, quantitative, target-based testing approaches as well as the need to consider a wide range of factors in establishing standardized approaches for NIRF imaging system performance.

  2. Evaluation of the quality of the reporting of phase II clinical trials in oncology: A systematic review.

    PubMed

    Rivoirard, Romain; Langrand-Escure, Julien; Oriol, Mathieu; Tinquaut, Fabien; Chauvin, Franck; Rancoule, Chloé; Magné, Nicolas; Bourmaud, Aurélie

    2018-05-01

    To describe the current state of knowledge concerning the quality of reporting in phase II clinical trials in oncology and to describe the various methods published allowing this quality evaluation. databases including MEDLINE and COCHRANE were searched. Reviews and meta-analyses analyzing the quality of the reporting of phase II trials in oncology were included. Descriptive analysis of the results was performed. Thirteen publications were retained. Only 2 publications adopted a systematic approach of evaluation of the quality of reporting by overall scores. The Key Methodological Score (KMS), proposed by Grellety et al., gathering 3 items, seemed adapted for such an evaluation. A score of 3/3 was found in 16.1% of the 156 phase II trials analysed by this score. The other reviews used a qualitative analysis to evaluate the reporting, via an analysis of a single criterion, generally the statistical plan of the study. This item was considered as having been correctly reported in less than 50% of the analysed articles. The quality of reporting in phase II trials in oncology is a field that has been investigated very little (13 publications). When it is studied, the estimated level of quality is not satisfactory, whatever the method employed. The use of an overall score of evaluation is a path which should be pursued, in order to get reliable results. It also seems necessary to propose strong recommendations, which would create a consensus for the methodology and the reporting of these studies. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Effects of different regulatory methods on improvement of greenhouse saline soils, tomato quality, and yield.

    PubMed

    Maomao, Hou; Xiaohou, Shao; Yaming, Zhai

    2014-01-01

    To identify effective regulatory methods scheduling with the compromise between the soil desalination and the improvement of tomato quality and yield, a 3-year field experiment was conducted to evaluate and compare the effect of straw mulching and soil structure conditioner and water-retaining agent on greenhouse saline soils, tomato quality, and yield. A higher salt removing rate of 80.72% in plough layer with straw mulching was obtained based on the observation of salt mass fraction in 0 ~ 20 cm soil layer before and after the experiment. Salts were also found to move gradually to the deeper soil layer with time. Straw mulching enhanced the content of soil organic matter significantly and was conductive to reserve soil available N, P, and K, while available P and K in soils of plough layer with soil structure conditioner decreased obviously; thus a greater usage of P fertilizer and K fertilizer was needed when applying soil structure conditioner. Considering the evaluation indexes including tomato quality, yield, and desalination effects of different regulatory methods, straw mulching was recommended as the main regulatory method to improve greenhouse saline soils in south China. Soil structure conditioner was the suboptimal method, which could be applied in concert with straw mulching.

  4. Evaluating the quality of Internet information for femoroacetabular impingement.

    PubMed

    Lee, Simon; Shin, Jason J; Haro, Marc S; Song, Sang H; Nho, Shane J

    2014-10-01

    The Internet has become a ubiquitous source of medical information for both the patient and the physician. However, the quality of this information is highly variable. We evaluated the quality of Internet information available for femoroacetabular impingement (FAI). Four popular search engines were used to collect 100 Web sites containing information on FAI. Web sites were evaluated based on authorship, various content criteria, and the presence of Health On the Net Code of Conduct (HONcode) certification. By use of a novel evaluation system for quality, Web sites were also classified as excellent, high, moderate, poor, or inadequate and were subsequently analyzed. Web sites were evaluated as a group, followed by authorship type, by HONcode certification, and by quality level. Of the Web sites, 73 offered the ability to contact the author, 91 offered a considerable explanation of FAI, 54 provided surgical treatment options, 58 offered nonsurgical treatment options, 27 discussed possible complications, 11 discussed eligibility criteria, 31 discussed rehabilitation, 67 discussed a differential diagnosis, and 48 included peer-reviewed citations. We categorized 40 Web sites as academic, 33 as private, 9 as industry, 9 as public education, and 9 as blogs. Our novel quality evaluation system classified 16 Web sites as excellent, 18 as high, 17 as moderate, 18 as poor, and 31 as inadequate. Only 8% of all evaluated Web sites contained HONcode certification. We found that the quality of information available on the Internet about FAI was dramatically variable. A significantly large proportion of Web sites were from academic sources, but this did not necessarily indicate higher quality. Sites with HONcode certification showed as much variability in quality as noncertified sites. This study increases clinician competence in the available Internet information about FAI and helps them to confidently guide patients to formulate appropriate medical decisions based on high-quality

  5. Coptidis rhizoma and its main bioactive components: recent advances in chemical investigation, quality evaluation and pharmacological activity.

    PubMed

    Meng, Fan-Cheng; Wu, Zheng-Feng; Yin, Zhi-Qi; Lin, Li-Gen; Wang, Ruibing; Zhang, Qing-Wen

    2018-01-01

    Coptidis rhizoma (CR) is the dried rhizome of Coptis chinensis Franch., C. deltoidea C. Y. Cheng et Hsiao or C. teeta Wall. (Ranunculaceae) and is commonly used in Traditional Chinese Medicine for the treatment of various diseases including bacillary dysentery, typhoid, tuberculosis, epidemic cerebrospinal meningitis, empyrosis, pertussis, and other illnesses. A literature survey was conducted via SciFinder, ScieneDirect, PubMed, Springer, and Wiley databases. A total of 139 selected references were classified on the basis of their research scopes, including chemical investigation, quality evaluation and pharmacological studies. Many types of secondary metabolites including alkaloids, lignans, phenylpropanoids, flavonoids, phenolic compounds, saccharides, and steroids have been isolated from CR. Among them, protoberberine-type alkaloids, such as berberine, palmatine, coptisine, epiberberine, jatrorrhizine, columamine, are the main components of CR. Quantitative determination of these alkaloids is a very important aspect in the quality evaluation of CR. In recent years, with the advances in isolation and detection technologies, many new instruments and methods have been developed for the quantitative and qualitative analysis of the main alkaloids from CR. The quality control of CR has provided safety for pharmacological applications. These quality evaluation methods are also frequently employed to screen the active components from CR. Various investigations have shown that CR and its main alkaloids exhibited many powerful pharmacological effects including anti-inflammatory, anti-cancer, anti-diabetic, neuroprotective, cardioprotective, hypoglycemic, anti-Alzheimer and hepatoprotective activities. This review summarizes the recent phytochemical investigations, quality evaluation methods, the biological studies focusing on CR as well as its main alkaloids.

  6. Water quality assessment of the Li Canal using a functional fuzzy synthetic evaluation model.

    PubMed

    Feng, Yan; Ling, Liu

    2014-07-01

    Through introducing functional data analysis (FDA) theory into the conventional fuzzy synthetic evaluation (FSE) method, the functional fuzzy synthetic evaluation (FFSE) model is established. FFSE keeps the property of the conventional FSE that the fuzziness in the water quality condition can be suitably measured. Furthermore, compared with FSE, FFSE has the following advantages: (1) FFSE requires fewer conditions for observation, for example, pollutants can be monitored at different times, and missing data is accepted; (2) the dynamic variation of the water quality condition can be represented more comprehensively and intuitively. The procedure of FFSE is discussed and the water quality of the Li Canal in 2012 is evaluated as an illustration. The synthetic classification of the Li Canal is "II" in January, February and July, and "I" in other months, which can satisfy the requirement of the Chinese South-to-North Water Diversion Project.

  7. Methods of Evaluating Child Welfare in Indian Country: An Illustration

    ERIC Educational Resources Information Center

    Fox, Kathleen; Cross, Terry L.; John, Laura; Carter, Patricia; Pavkov, Thomas; Wang, Ching-Tung; Diaz, Javier

    2011-01-01

    The poor quality and quantity of data collected in tribal communities today reflects a lack of true community participation and commitment. This is especially problematic for evaluation studies, in which the needs and desires of the community should be the central focus. This challenge can be met by emphasizing indigenous methods and voice. The…

  8. Evaluation models and criteria of the quality of hospital websites: a systematic review study.

    PubMed

    Jeddi, Fatemeh Rangraz; Gilasi, Hamidreza; Khademi, Sahar

    2017-02-01

    Hospital websites are important tools in establishing communication and exchanging information between patients and staff, and thus should enjoy an acceptable level of quality. The aim of this study was to identify proper models and criteria to evaluate the quality of hospital websites. This research was a systematic review study. The international databases such as Science Direct, Google Scholar, PubMed, Proquest, Ovid, Elsevier, Springer, and EBSCO together with regional database such as Magiran, Scientific Information Database, Persian Journal Citation Report (PJCR) and IranMedex were searched. Suitable keywords including website, evaluation, and quality of website were used. Full text papers related to the research were included. The criteria and sub criteria of the evaluation of website quality were extracted and classified. To evaluate the quality of the websites, various models and criteria were presented. The WEB-Q-IM, Mile, Minerva, Seruni Luci, and Web-Qual models were the designed models. The criteria of accessibility, content and apparent features of the websites, the design procedure, the graphics applied in the website, and the page's attractions have been mentioned in the majority of studies. The criteria of accessibility, content, design method, security, and confidentiality of personal information are the essential criteria in the evaluation of all websites. It is suggested that the ease of use, graphics, attractiveness and other apparent properties of websites are considered as the user-friendliness sub criteria. Further, the criteria of speed and accessibility of the website should be considered as sub criterion of efficiency. When determining the evaluation criteria of the quality of websites, attention to major differences in the specific features of any website is essential.

  9. [An improved medical image fusion algorithm and quality evaluation].

    PubMed

    Chen, Meiling; Tao, Ling; Qian, Zhiyu

    2009-08-01

    Medical image fusion is of very important value for application in medical image analysis and diagnosis. In this paper, the conventional method of wavelet fusion is improved,so a new algorithm of medical image fusion is presented and the high frequency and low frequency coefficients are studied respectively. When high frequency coefficients are chosen, the regional edge intensities of each sub-image are calculated to realize adaptive fusion. The choice of low frequency coefficient is based on the edges of images, so that the fused image preserves all useful information and appears more distinctly. We apply the conventional and the improved fusion algorithms based on wavelet transform to fuse two images of human body and also evaluate the fusion results through a quality evaluation method. Experimental results show that this algorithm can effectively retain the details of information on original images and enhance their edge and texture features. This new algorithm is better than the conventional fusion algorithm based on wavelet transform.

  10. Evaluation and testing of image quality of the Space Solar Extreme Ultraviolet Telescope

    NASA Astrophysics Data System (ADS)

    Peng, Jilong; Yi, Zhong; Zhou, Shuhong; Yu, Qian; Hou, Yinlong; Wang, Shanshan

    2018-01-01

    For the space solar extreme ultraviolet telescope, the star point test can not be performed in the x-ray band (19.5nm band) as there is not light source of bright enough. In this paper, the point spread function of the optical system is calculated to evaluate the imaging performance of the telescope system. Combined with the actual processing surface error, such as small grinding head processing and magnetorheological processing, the optical design software Zemax and data analysis software Matlab are used to directly calculate the system point spread function of the space solar extreme ultraviolet telescope. Matlab codes are programmed to generate the required surface error grid data. These surface error data is loaded to the specified surface of the telescope system by using the communication technique of DDE (Dynamic Data Exchange), which is used to connect Zemax and Matlab. As the different processing methods will lead to surface error with different size, distribution and spatial frequency, the impact of imaging is also different. Therefore, the characteristics of the surface error of different machining methods are studied. Combining with its position in the optical system and simulation its influence on the image quality, it is of great significance to reasonably choose the processing technology. Additionally, we have also analyzed the relationship between the surface error and the image quality evaluation. In order to ensure the final processing of the mirror to meet the requirements of the image quality, we should choose one or several methods to evaluate the surface error according to the different spatial frequency characteristics of the surface error.

  11. Evaluating quantity and quality of literature focusing on health economics and pharmacoeconomics in Gulf Cooperation Council countries.

    PubMed

    Eljilany, Islam; El-Dahiyat, Faris; Curley, Louise Elizabeth; Babar, Zaheer-Ud-Din

    2018-05-30

    The importance of pharmacoeconomics and health economics has been augmented. It has the potential to provide evidence to aid in optimal decision-making in the funding of cost-effective medicines and services in Gulf Cooperation Council countries (G.C.C). To evaluate the quality and quantity of health economic researches published until the end of 2017 in G.C.C. and to identify the factors that affect the quality of studies. Studies were included according to predefined inclusion and exclusion criteria. The quantity was recorded, and the quality was assessed using the Quality of Health Economic Studies (QHES) instrument. Forty-nine studies were included. The mean (SD) quality score of all studies was 57.83 (25.05), and a high number of reviewed studies (47%) were evaluated as either poor or extremely poor quality. The factors that affect the quality of studies with statistical significance were, the type and method of economic evaluation, the economic outcome was the objective of the research, author`s background, the perspective of the study, health intervention and source of funding. The use of economic evaluation studies in G.C.C was limited. Different factors that affect the quality of articles such as performing a full economic evaluation and choosing societal perspective were identified. Strategies to improve the quality of future studies were recommended.

  12. Quality of Protection Evaluation of Security Mechanisms

    PubMed Central

    Ksiezopolski, Bogdan; Zurek, Tomasz; Mokkas, Michail

    2014-01-01

    Recent research indicates that during the design of teleinformatic system the tradeoff between the systems performance and the system protection should be made. The traditional approach assumes that the best way is to apply the strongest possible security measures. Unfortunately, the overestimation of security measures can lead to the unreasonable increase of system load. This is especially important in multimedia systems where the performance has critical character. In many cases determination of the required level of protection and adjustment of some security measures to these requirements increase system efficiency. Such an approach is achieved by means of the quality of protection models where the security measures are evaluated according to their influence on the system security. In the paper, we propose a model for QoP evaluation of security mechanisms. Owing to this model, one can quantify the influence of particular security mechanisms on ensuring security attributes. The methodology of our model preparation is described and based on it the case study analysis is presented. We support our method by the tool where the models can be defined and QoP evaluation can be performed. Finally, we have modelled TLS cryptographic protocol and presented the QoP security mechanisms evaluation for the selected versions of this protocol. PMID:25136683

  13. Quality of protection evaluation of security mechanisms.

    PubMed

    Ksiezopolski, Bogdan; Zurek, Tomasz; Mokkas, Michail

    2014-01-01

    Recent research indicates that during the design of teleinformatic system the tradeoff between the systems performance and the system protection should be made. The traditional approach assumes that the best way is to apply the strongest possible security measures. Unfortunately, the overestimation of security measures can lead to the unreasonable increase of system load. This is especially important in multimedia systems where the performance has critical character. In many cases determination of the required level of protection and adjustment of some security measures to these requirements increase system efficiency. Such an approach is achieved by means of the quality of protection models where the security measures are evaluated according to their influence on the system security. In the paper, we propose a model for QoP evaluation of security mechanisms. Owing to this model, one can quantify the influence of particular security mechanisms on ensuring security attributes. The methodology of our model preparation is described and based on it the case study analysis is presented. We support our method by the tool where the models can be defined and QoP evaluation can be performed. Finally, we have modelled TLS cryptographic protocol and presented the QoP security mechanisms evaluation for the selected versions of this protocol.

  14. Evaluation Instruments for Quality of Life Related to Melasma: An Integrative Review.

    PubMed

    Pollo, Camila Fernandes; Meneguin, Silmara; Miot, Helio Amante

    2018-05-21

    The aim of this study was to analyze scientific production concerning the validation and cultural adaptation of quality of life evaluation instruments for patients with melasma and to offer a critical reflection on these methods. A literature review was performed based on a search of the Web of Science, Bireme, PubMed, Elsevier Scopus, and Google Scholar databases. All published articles from indexed periodicals in these electronic databases up to December 2015 were included. Eight articles were identified, of which only one (12.5%) referred to the development and validation of a specific instrument for evaluation of the quality of life of melasma patients. An additional six articles (75%) referred to transcultural adjustment and validation of the same instrument in other languages, and another (12.5%) article reported the development of a generic instrument for evaluation of quality of life in patients with pigment disorders. This review revealed only one specific instrument developed and validated in different cultures. Despite being widely used, this instrument did not follow the classic construction steps for psychometric instruments, which paves the way for future studies to develop novel instruments.

  15. Evaluation Instruments for Quality of Life Related to Melasma: An Integrative Review

    PubMed Central

    Pollo, Camila Fernandes; Meneguin, Silmara; Miot, Helio Amante

    2018-01-01

    The aim of this study was to analyze scientific production concerning the validation and cultural adaptation of quality of life evaluation instruments for patients with melasma and to offer a critical reflection on these methods. A literature review was performed based on a search of the Web of Science, Bireme, PubMed, Elsevier Scopus, and Google Scholar databases. All published articles from indexed periodicals in these electronic databases up to December 2015 were included. Eight articles were identified, of which only one (12.5%) referred to the development and validation of a specific instrument for evaluation of the quality of life of melasma patients. An additional six articles (75%) referred to transcultural adjustment and validation of the same instrument in other languages, and another (12.5%) article reported the development of a generic instrument for evaluation of quality of life in patients with pigment disorders. This review revealed only one specific instrument developed and validated in different cultures. Despite being widely used, this instrument did not follow the classic construction steps for psychometric instruments, which paves the way for future studies to develop novel instruments. PMID:29791603

  16. QUALITY OF LIFE AFTER VERTICAL GASTRECTOMY EVALUATED BY THE BAROS QUESTIONNAIRE

    PubMed Central

    VARGAS, Guilherme Pedroso; MENDES, Giselle Abigail; Pinto, Rinaldo Danesi

    2017-01-01

    ABSTRACT Background : The satisfactory outcome in the surgical treatment of obesity must include, in addition to weight loss, a significant change in the pre-existing comorbidities and in the quality of life of the patients. Aim : To evaluate the quality of life in the late postoperative period in patients that underwent videolaparoscopic sleeve gastrectomy. Methods : Was applied the questionnaire “Bariatric Analysis and Reporting Outcome System” (BAROS) in patients that underwent videolaparoscopic sleeve gastrectomy. Results : A total of 47 patients between 21-60 years old were evaluated. The total mean of the BMI before surgery was 43.06±5.87 kg/m². The average percentage of the reduction of excess weight after surgery was 85.46±23.6%. The score obtained by patients in the questionnaire about the improvement in the quality of life showed excellent (36.17%), very good (40.43%), good (21.28%) and reasonable (2.13%) results. There was clinical improvement after surgery in all comorbidities investigated. Conclusion : BAROS showed excellent results in 36.17%, very good in 40.43%, good in 21.28% and reasonable in 2.13%. The weight loss was critical to improve the quality of life and offered the resolution or clinical improvement in all of the investigated comorbidities. PMID:29340547

  17. Through Their Eyes: Lessons Learned Using Participatory Methods in Health Care Quality Improvement Projects

    PubMed Central

    Balbale, Salva N.; Locatelli, Sara M.; LaVela, Sherri L.

    2016-01-01

    In this methodological article, we examine participatory methods in-depth to demonstrate how these methods can be adopted for quality improvement (QI) projects in health care. We draw on existing literature and our QI initiatives in the Department of Veterans Affairs to discuss the application of photovoice and guided tours in QI efforts. We highlight lessons learned and several benefits of using participatory methods in this area. Using participatory methods, evaluators can engage patients, providers and other stakeholders as partners to enhance care. Participant involvement helps yield actionable data that can be translated into improved care practices. Use of these methods also helps generate key insights to inform improvements that truly resonate with stakeholders. Using participatory methods is a valuable strategy to harness participant engagement and drive improvements that address individual needs. In applying these innovative methodologies, evaluators can transcend traditional approaches to uniquely support evaluations and improvements in health care. PMID:26667882

  18. Through Their Eyes: Lessons Learned Using Participatory Methods in Health Care Quality Improvement Projects.

    PubMed

    Balbale, Salva N; Locatelli, Sara M; LaVela, Sherri L

    2016-08-01

    In this methodological article, we examine participatory methods in depth to demonstrate how these methods can be adopted for quality improvement (QI) projects in health care. We draw on existing literature and our QI initiatives in the Department of Veterans Affairs to discuss the application of photovoice and guided tours in QI efforts. We highlight lessons learned and several benefits of using participatory methods in this area. Using participatory methods, evaluators can engage patients, providers, and other stakeholders as partners to enhance care. Participant involvement helps yield actionable data that can be translated into improved care practices. Use of these methods also helps generate key insights to inform improvements that truly resonate with stakeholders. Using participatory methods is a valuable strategy to harness participant engagement and drive improvements that address individual needs. In applying these innovative methodologies, evaluators can transcend traditional approaches to uniquely support evaluations and improvements in health care. © The Author(s) 2015.

  19. Development of a quality instrument for assessing the spontaneous reports of ADR/ADE using Delphi method in China.

    PubMed

    Chen, Lixun; Jiang, Ling; Shen, Aizong; Wei, Wei

    2016-09-01

    The frequently low quality of submitted spontaneous reports is of an increasing concern; to our knowledge, no validated instrument exists for assessing case reports' quality comprehensively enough. This work was conducted to develop such a quality instrument for assessing the spontaneous reports of adverse drug reaction (ADR)/adverse drug event (ADE) in China. Initial evaluation indicators were generated using systematic and literature data analysis. Final indicators and their weights were identified using Delphi method. The final quality instrument was developed by adopting the synthetic scoring method. A consensus was reached after four rounds of Delphi survey. The developed quality instrument consisted of 6 first-rank indicators, 18 second-rank indicators, and 115 third-rank indicators, and each rank indicator has been weighted. It evaluates the quality of spontaneous reports of ADR/ADE comprehensively and quantitatively on six parameters: authenticity, duplication, regulatory, completeness, vigilance level, and reporting time frame. The developed instrument was tested with good reliability and validity, which can be used to comprehensively and quantitatively assess the submitted spontaneous reports of ADR/ADE in China.

  20. 21 CFR 26.43 - Transmission of quality system evaluation reports.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... QUALITY SYSTEM AUDIT REPORTS, AND CERTAIN MEDICAL DEVICE PRODUCT EVALUATION REPORTS: UNITED STATES AND THE EUROPEAN COMMUNITY Specific Sector Provisions for Medical Devices § 26.43 Transmission of quality system... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Transmission of quality system evaluation reports...

  1. Atmospheric Model Evaluation Tool for meteorological and air quality simulations

    EPA Pesticide Factsheets

    The Atmospheric Model Evaluation Tool compares model predictions to observed data from various meteorological and air quality observation networks to help evaluate meteorological and air quality simulations.

  2. Audiovisual quality evaluation of low-bitrate video

    NASA Astrophysics Data System (ADS)

    Winkler, Stefan; Faller, Christof

    2005-03-01

    Audiovisual quality assessment is a relatively unexplored topic. We designed subjective experiments for audio, video, and audiovisual quality using content and encoding parameters representative of video for mobile applications. Our focus were the MPEG-4 AVC (a.k.a. H.264) and AAC coding standards. Our goals in this study are two-fold: we want to understand the interactions between audio and video in terms of perceived audiovisual quality, and we use the subjective data to evaluate the prediction performance of our non-reference video and audio quality metrics.

  3. Evaluation of the Ecochemical Status of the Danube in Serbia in Terms of Water Quality Parameters

    PubMed Central

    Takić, Ljiljana; Mladenović-Ranisavljević, Ivana; Vuković, Milovan; Mladenović, Ilija

    2012-01-01

    The Danube is an international river passing partly through Serbia. The protection of the environment and sustainable use of water resources is a primary task that implies constant monitoring of the quality status and evaluation of ecochemical status of the water in the Danube basin. The investigation includes calculation of all-inclusive water quality by the Serbian water quality index (SWQI) method and an evaluation of eco-chemical status of the Danube water in terms of water quality parameters from the entry to the exit point along its course through Serbia in the year of 2009. The results show that the overall quality of the Danube water on the territory of Serbia corresponds to the descriptive indicator of “very good” water. According to the Council Directive75/440/EEC, the evaluation of the ecostatus, with slight deviation of individual parameters at Pančevo, corresponds to A1 category of the surface water quality intended for the abstraction of drinking water supplies in member states. PMID:22645471

  4. Seminal quality prediction using data mining methods.

    PubMed

    Sahoo, Anoop J; Kumar, Yugal

    2014-01-01

    Now-a-days, some new classes of diseases have come into existences which are known as lifestyle diseases. The main reasons behind these diseases are changes in the lifestyle of people such as alcohol drinking, smoking, food habits etc. After going through the various lifestyle diseases, it has been found that the fertility rates (sperm quantity) in men has considerably been decreasing in last two decades. Lifestyle factors as well as environmental factors are mainly responsible for the change in the semen quality. The objective of this paper is to identify the lifestyle and environmental features that affects the seminal quality and also fertility rate in man using data mining methods. The five artificial intelligence techniques such as Multilayer perceptron (MLP), Decision Tree (DT), Navie Bayes (Kernel), Support vector machine+Particle swarm optimization (SVM+PSO) and Support vector machine (SVM) have been applied on fertility dataset to evaluate the seminal quality and also to predict the person is either normal or having altered fertility rate. While the eight feature selection techniques such as support vector machine (SVM), neural network (NN), evolutionary logistic regression (LR), support vector machine plus particle swarm optimization (SVM+PSO), principle component analysis (PCA), chi-square test, correlation and T-test methods have been used to identify more relevant features which affect the seminal quality. These techniques are applied on fertility dataset which contains 100 instances with nine attribute with two classes. The experimental result shows that SVM+PSO provides higher accuracy and area under curve (AUC) rate (94% & 0.932) among multi-layer perceptron (MLP) (92% & 0.728), Support Vector Machines (91% & 0.758), Navie Bayes (Kernel) (89% & 0.850) and Decision Tree (89% & 0.735) for some of the seminal parameters. This paper also focuses on the feature selection process i.e. how to select the features which are more important for prediction of

  5. Assessment of Methodological Quality of Economic Evaluations in Belgian Drug Reimbursement Applications

    PubMed Central

    Simoens, Steven

    2013-01-01

    Objectives This paper aims to assess the methodological quality of economic evaluations included in Belgian reimbursement applications for Class 1 drugs. Materials and Methods For 19 reimbursement applications submitted during 2011 and Spring 2012, a descriptive analysis assessed the methodological quality of the economic evaluation, evaluated the assessment of that economic evaluation by the Drug Reimbursement Committee and the response to that assessment by the company. Compliance with methodological guidelines issued by the Belgian Healthcare Knowledge Centre was assessed using a detailed checklist of 23 methodological items. The rate of compliance was calculated based on the number of economic evaluations for which the item was applicable. Results Economic evaluations tended to comply with guidelines regarding perspective, target population, subgroup analyses, comparator, use of comparative clinical data and final outcome measures, calculation of costs, incremental analysis, discounting and time horizon. However, more attention needs to be paid to the description of limitations of indirect comparisons, the choice of an appropriate analytic technique, the expression of unit costs in values for the current year, the estimation and valuation of outcomes, the presentation of results of sensitivity analyses, and testing the face validity of model inputs and outputs. Also, a large variation was observed in the scope and depth of the quality assessment by the Drug Reimbursement Committee. Conclusions Although general guidelines exist, pharmaceutical companies and the Drug Reimbursement Committee would benefit from the existence of a more detailed checklist of methodological items that need to be reported in an economic evaluation. PMID:24386474

  6. Quality evaluation of Persian nutrition and diet therapy websites.

    PubMed

    Gholizadeh, Zahra; Papi, Ahmad; Ashrafi-Rizi, Hasan; Shahrzadi, Leila; Hasanzadeh, Akbar

    2017-01-01

    Nowadays websites are among the most important information sources used by most people. With the spread of websites, especially those related to health issues, the number of their visitors also increases, more than half of which are about nutritional information. Therefore, quality analysis of nutrition and diet therapy websites is of outmost importance. This study aims to evaluate the quality of Persian nutrition and diet therapy websites. The current work is a survey study and uses an applied study method. The statistical population consists of 51 Persian websites about nutrition and diet therapy and census method was used in order to study them. Data gathering was done using a checklist and with direct visit to each website. Descriptive and analytical statistics were used to analyse the gathered data with the help of SPSS 21 software. Findings showed that content (66.7%), organization (82.4%), user friendly interfaces (52.9%) and total quality (70.6%) of most websites had a mediocre score while the design score for most of the websites (70.6%) was acceptable also organizational websites had better design, organization and quality compared to private websites. The three websites with the highest general quality score were the websites of "Novel Diet Therapy," "Behsite" and "Dr. BehdadiPour" (jointly) and "Dr. Kermani" respectively. Also in the dimension of content the factors of goal, relevance and credibility, in the dimension of design the factors of color, text and sound, pictures and videos, in the dimension of organization the factors of stability and indexing and in the dimension of user friendliness the factors of confidentiality, credibility and personalization had the highest scores. The results showed that the design score was higher than other scores. Also the general quality score of the websites was mediocre and was not desirable. Also websites didn't have suitable scores in every factor. Since most people search the internet for nutritional and diet

  7. Using and Reporting the Delphi Method for Selecting Healthcare Quality Indicators: A Systematic Review

    PubMed Central

    Boulkedid, Rym; Abdoul, Hendy; Loustau, Marine; Sibony, Olivier; Alberti, Corinne

    2011-01-01

    Objective Delphi technique is a structured process commonly used to developed healthcare quality indicators, but there is a little recommendation for researchers who wish to use it. This study aimed 1) to describe reporting of the Delphi method to develop quality indicators, 2) to discuss specific methodological skills for quality indicators selection 3) to give guidance about this practice. Methodology and Main Finding Three electronic data bases were searched over a 30 years period (1978–2009). All articles that used the Delphi method to select quality indicators were identified. A standardized data extraction form was developed. Four domains (questionnaire preparation, expert panel, progress of the survey and Delphi results) were assessed. Of 80 included studies, quality of reporting varied significantly between items (9% for year's number of experience of the experts to 98% for the type of Delphi used). Reporting of methodological aspects needed to evaluate the reliability of the survey was insufficient: only 39% (31/80) of studies reported response rates for all rounds, 60% (48/80) that feedback was given between rounds, 77% (62/80) the method used to achieve consensus and 57% (48/80) listed quality indicators selected at the end of the survey. A modified Delphi procedure was used in 49/78 (63%) with a physical meeting of the panel members, usually between Delphi rounds. Median number of panel members was 17(Q1:11; Q3:31). In 40/70 (57%) studies, the panel included multiple stakeholders, who were healthcare professionals in 95% (38/40) of cases. Among 75 studies describing criteria to select quality indicators, 28 (37%) used validity and 17(23%) feasibility. Conclusion The use and reporting of the Delphi method for quality indicators selection need to be improved. We provide some guidance to the investigators to improve the using and reporting of the method in future surveys. PMID:21694759

  8. Using and reporting the Delphi method for selecting healthcare quality indicators: a systematic review.

    PubMed

    Boulkedid, Rym; Abdoul, Hendy; Loustau, Marine; Sibony, Olivier; Alberti, Corinne

    2011-01-01

    Delphi technique is a structured process commonly used to developed healthcare quality indicators, but there is a little recommendation for researchers who wish to use it. This study aimed 1) to describe reporting of the Delphi method to develop quality indicators, 2) to discuss specific methodological skills for quality indicators selection 3) to give guidance about this practice. Three electronic data bases were searched over a 30 years period (1978-2009). All articles that used the Delphi method to select quality indicators were identified. A standardized data extraction form was developed. Four domains (questionnaire preparation, expert panel, progress of the survey and Delphi results) were assessed. Of 80 included studies, quality of reporting varied significantly between items (9% for year's number of experience of the experts to 98% for the type of Delphi used). Reporting of methodological aspects needed to evaluate the reliability of the survey was insufficient: only 39% (31/80) of studies reported response rates for all rounds, 60% (48/80) that feedback was given between rounds, 77% (62/80) the method used to achieve consensus and 57% (48/80) listed quality indicators selected at the end of the survey. A modified Delphi procedure was used in 49/78 (63%) with a physical meeting of the panel members, usually between Delphi rounds. Median number of panel members was 17(Q1:11; Q3:31). In 40/70 (57%) studies, the panel included multiple stakeholders, who were healthcare professionals in 95% (38/40) of cases. Among 75 studies describing criteria to select quality indicators, 28 (37%) used validity and 17(23%) feasibility. The use and reporting of the Delphi method for quality indicators selection need to be improved. We provide some guidance to the investigators to improve the using and reporting of the method in future surveys.

  9. Evaluation of the quality of antenatal care using electronic health record information in family medicine clinics of Mexico City.

    PubMed

    Doubova, Svetlana V; Pérez-Cuevas, Ricardo; Ortiz-Panozo, Eduardo; Hernández-Prado, Bernardo

    2014-05-16

    Evaluation of the quality of antenatal care (ANC) using indicators should be part of the efforts to improve primary care services in developing countries. The growing use of the electronic health record (EHR) has the potential of making the evaluation more efficient. The objectives of this study were: (a) to develop quality indicators for ANC and (b) to evaluate the quality of ANC using EHR information in family medicine clinics (FMCs) of Mexico City. We used a mixed methods approach including: (a) in-depth interviews with health professionals; (b) development of indicators following the RAND-UCLA method; (c) a retrospective cohort study of quality of care provided to 5342 women aged 12-49 years who had completed their pregnancy in 2009 and attended to at least one ANC visit with their family doctor. The study took place in four FMCs located in Mexico City. The source of information was the EHR. SAS statistical package served for programing and performing the descriptive statistical analysis. 14 ANC quality indicators were developed. The evaluation showed that 40.6% of women began ANC in the first trimester; 63.5% with low-risk pregnancy attended four or more ANC visits; 4.4% were referred for routine obstetric ultrasound, and 41.1% with vaginal infection were prescribed metronidazole. On average, the percentage of recommended care that women received was 32.7%. It is feasible to develop quality indicators suitable for evaluating the quality of ANC using routine EHR data. The study identified the ANC areas that require improvement; which can guide future strategies aimed at improving ANC quality.

  10. Evaluation of an iterative model-based reconstruction of pediatric abdominal CT with regard to image quality and radiation dose.

    PubMed

    Aurumskjöld, Marie-Louise; Söderberg, Marcus; Stålhammar, Fredrik; von Steyern, Kristina Vult; Tingberg, Anders; Ydström, Kristina

    2018-06-01

    Background In pediatric patients, computed tomography (CT) is important in the medical chain of diagnosing and monitoring various diseases. Because children are more radiosensitive than adults, they require minimal radiation exposure. One way to achieve this goal is to implement new technical solutions, like iterative reconstruction. Purpose To evaluate the potential of a new, iterative, model-based method for reconstructing (IMR) pediatric abdominal CT at a low radiation dose and determine whether it maintains or improves image quality, compared to the current reconstruction method. Material and Methods Forty pediatric patients underwent abdominal CT. Twenty patients were examined with the standard dose settings and 20 patients were examined with a 32% lower radiation dose. Images from the standard examination were reconstructed with a hybrid iterative reconstruction method (iDose 4 ), and images from the low-dose examinations were reconstructed with both iDose 4 and IMR. Image quality was evaluated subjectively by three observers, according to modified EU image quality criteria, and evaluated objectively based on the noise observed in liver images. Results Visual grading characteristics analyses showed no difference in image quality between the standard dose examination reconstructed with iDose 4 and the low dose examination reconstructed with IMR. IMR showed lower image noise in the liver compared to iDose 4 images. Inter- and intra-observer variance was low: the intraclass coefficient was 0.66 (95% confidence interval = 0.60-0.71) for the three observers. Conclusion IMR provided image quality equivalent or superior to the standard iDose 4 method for evaluating pediatric abdominal CT, even with a 32% dose reduction.

  11. Using collective expert judgements to evaluate quality measures of mass spectrometry images.

    PubMed

    Palmer, Andrew; Ovchinnikova, Ekaterina; Thuné, Mikael; Lavigne, Régis; Guével, Blandine; Dyatlov, Andrey; Vitek, Olga; Pineau, Charles; Borén, Mats; Alexandrov, Theodore

    2015-06-15

    Imaging mass spectrometry (IMS) is a maturating technique of molecular imaging. Confidence in the reproducible quality of IMS data is essential for its integration into routine use. However, the predominant method for assessing quality is visual examination, a time consuming, unstandardized and non-scalable approach. So far, the problem of assessing the quality has only been marginally addressed and existing measures do not account for the spatial information of IMS data. Importantly, no approach exists for unbiased evaluation of potential quality measures. We propose a novel approach for evaluating potential measures by creating a gold-standard set using collective expert judgements upon which we evaluated image-based measures. To produce a gold standard, we engaged 80 IMS experts, each to rate the relative quality between 52 pairs of ion images from MALDI-TOF IMS datasets of rat brain coronal sections. Experts' optional feedback on their expertise, the task and the survey showed that (i) they had diverse backgrounds and sufficient expertise, (ii) the task was properly understood, and (iii) the survey was comprehensible. A moderate inter-rater agreement was achieved with Krippendorff's alpha of 0.5. A gold-standard set of 634 pairs of images with accompanying ratings was constructed and showed a high agreement of 0.85. Eight families of potential measures with a range of parameters and statistical descriptors, giving 143 in total, were evaluated. Both signal-to-noise and spatial chaos-based measures performed highly with a correlation of 0.7 to 0.9 with the gold standard ratings. Moreover, we showed that a composite measure with the linear coefficients (trained on the gold standard with regularized least squares optimization and lasso) showed a strong linear correlation of 0.94 and an accuracy of 0.98 in predicting which image in a pair was of higher quality. The anonymized data collected from the survey and the Matlab source code for data processing can be found

  12. Using collective expert judgements to evaluate quality measures of mass spectrometry images

    PubMed Central

    Palmer, Andrew; Ovchinnikova, Ekaterina; Thuné, Mikael; Lavigne, Régis; Guével, Blandine; Dyatlov, Andrey; Vitek, Olga; Pineau, Charles; Borén, Mats; Alexandrov, Theodore

    2015-01-01

    Motivation: Imaging mass spectrometry (IMS) is a maturating technique of molecular imaging. Confidence in the reproducible quality of IMS data is essential for its integration into routine use. However, the predominant method for assessing quality is visual examination, a time consuming, unstandardized and non-scalable approach. So far, the problem of assessing the quality has only been marginally addressed and existing measures do not account for the spatial information of IMS data. Importantly, no approach exists for unbiased evaluation of potential quality measures. Results: We propose a novel approach for evaluating potential measures by creating a gold-standard set using collective expert judgements upon which we evaluated image-based measures. To produce a gold standard, we engaged 80 IMS experts, each to rate the relative quality between 52 pairs of ion images from MALDI-TOF IMS datasets of rat brain coronal sections. Experts’ optional feedback on their expertise, the task and the survey showed that (i) they had diverse backgrounds and sufficient expertise, (ii) the task was properly understood, and (iii) the survey was comprehensible. A moderate inter-rater agreement was achieved with Krippendorff’s alpha of 0.5. A gold-standard set of 634 pairs of images with accompanying ratings was constructed and showed a high agreement of 0.85. Eight families of potential measures with a range of parameters and statistical descriptors, giving 143 in total, were evaluated. Both signal-to-noise and spatial chaos-based measures performed highly with a correlation of 0.7 to 0.9 with the gold standard ratings. Moreover, we showed that a composite measure with the linear coefficients (trained on the gold standard with regularized least squares optimization and lasso) showed a strong linear correlation of 0.94 and an accuracy of 0.98 in predicting which image in a pair was of higher quality. Availability and implementation: The anonymized data collected from the survey

  13. Quality evaluation of yellow peach chips prepared by explosion puffing drying.

    PubMed

    Lyu, Jian; Zhou, Lin-Yan; Bi, Jin-Feng; Liu, Xuan; Wu, Xin-Ye

    2015-12-01

    Nineteen evaluation indicators in 15 yellow peach chips prepared by explosion puffing drying were analyzed, including color, rehydration ratio, texture, and so on. The analysis methods of principle component analysis (PCA), analytic hierarchy process (AHP), K-means cluster (KC) and Discriminate analysis (DA) were used to analyze the comprehensive quality of the yellow peach chips. The dispersed coefficient of variation of the 19 evaluation indicators varied from 3.58 to 852.89 %, suggesting significant differences among yellow peach cultivars. The characteristic evaluation indicators, namely, reducing sugar content, out-put ratio, water content, a value and L value were analyzed by PCA, and their weights 0.0429, 0.1140, 0.4816, 1.1807 and 0.1807 were obtained by AHP. The levels in 15 cultivars effectively were classified by discrimination functions which obtained by KC and DA. The results suggested that three levels of comprehensive quality for yellow peach chips were divided, and the highest synthesis scores was observed in "senggelin" (11.1037), while the lowest synthesis value was found in "goldbaby" (-3.7600).

  14. Single-case synthesis tools I: Comparing tools to evaluate SCD quality and rigor.

    PubMed

    Zimmerman, Kathleen N; Ledford, Jennifer R; Severini, Katherine E; Pustejovsky, James E; Barton, Erin E; Lloyd, Blair P

    2018-03-03

    Tools for evaluating the quality and rigor of single case research designs (SCD) are often used when conducting SCD syntheses. Preferred components include evaluations of design features related to the internal validity of SCD to obtain quality and/or rigor ratings. Three tools for evaluating the quality and rigor of SCD (Council for Exceptional Children, What Works Clearinghouse, and Single-Case Analysis and Design Framework) were compared to determine if conclusions regarding the effectiveness of antecedent sensory-based interventions for young children changed based on choice of quality evaluation tool. Evaluation of SCD quality differed across tools, suggesting selection of quality evaluation tools impacts evaluation findings. Suggestions for selecting an appropriate quality and rigor assessment tool are provided and across-tool conclusions are drawn regarding the quality and rigor of studies. Finally, authors provide guidance for using quality evaluations in conjunction with outcome analyses when conducting syntheses of interventions evaluated in the context of SCD. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. A Multi-level Fuzzy Evaluation Method for Smart Distribution Network Based on Entropy Weight

    NASA Astrophysics Data System (ADS)

    Li, Jianfang; Song, Xiaohui; Gao, Fei; Zhang, Yu

    2017-05-01

    Smart distribution network is considered as the future trend of distribution network. In order to comprehensive evaluate smart distribution construction level and give guidance to the practice of smart distribution construction, a multi-level fuzzy evaluation method based on entropy weight is proposed. Firstly, focus on both the conventional characteristics of distribution network and new characteristics of smart distribution network such as self-healing and interaction, a multi-level evaluation index system which contains power supply capability, power quality, economy, reliability and interaction is established. Then, a combination weighting method based on Delphi method and entropy weight method is put forward, which take into account not only the importance of the evaluation index in the experts’ subjective view, but also the objective and different information from the index values. Thirdly, a multi-level evaluation method based on fuzzy theory is put forward. Lastly, an example is conducted based on the statistical data of some cites’ distribution network and the evaluation method is proved effective and rational.

  16. Effectiveness Comparison of TxDOT Quality Control/Quality Assurance and Method Specifications

    DOT National Transportation Integrated Search

    1998-12-01

    Original Report date: October 1997. This is the first and final report for research project 0-1721, "Effectiveness Comparison of TxDOT Quality Control/Quality Assurance and Method Specifications." This study was established and sponsored by TxDOT to ...

  17. Quality evaluation of cook-chilled chicory stems (Cichorium intybus L., Catalogna group) by conventional and sous vide cooking methods.

    PubMed

    Renna, Massimiliano; Gonnella, Maria; Giannino, Donato; Santamaria, Pietro

    2014-03-15

    Chicory stems, appreciated both raw and cooked, represent a nutritious and refined food. In this study the effects on the quality of stems cooked by conventional (boiling, steaming and microwaving) and innovative (sous vide) methods were analysed. Several physical, chemical and sensory traits were compared using two local varieties (Galatina and Molfettese) of southern Italy (Puglia region). Independently of the variety, the sous vide method did not significantly affect (redness, yellowness and hue angle) or had the least impact on (lightness and total colour difference) quality parameters among the four methods as compared with the raw product. Following sensory analysis, the sous vide product always showed the highest score among the cooking methods. Moreover, this innovative method did not affect total phenol (TP) content and antioxidant activity (AA) compared with uncooked stems of both varieties. Microwaving increased TP content and AA (though associated with higher weight loss), while different responses depending on the chicory variety were observed after boiling and steaming. The results indicate the sous vide technique as optimal to preserve several traits, including organoleptic ones, for the quality of cook-chilled chicory stems. They also provide product-specific information usually required for cooking process strategies in the industrial sector of ready-to-eat vegetables. © 2013 Society of Chemical Industry.

  18. Evaluation of Aesthetic and Quality-of-Life Results after Immediate Breast Reconstruction with Definitive Form-Stable Anatomical Implants.

    PubMed

    Kuroda, Flavia; Urban, Cicero; Zucca-Matthes, Gustavo; de Oliveira, Vilmar Marques; Arana, Gabriel Hubner; Iera, Marco; Rietjens, Mario; Santos, Gabriela; Spagnol, Caroline; de Lima, Rubens Silveira

    2016-02-01

    Although there are many reports on different techniques in breast reconstruction, there are few data regarding immediate breast reconstruction with definitive form-stable anatomical implants in terms of aesthetics and quality-of-life outcomes. Ninety-four patients underwent mastectomy with immediate breast reconstruction using anatomical implants and contralateral symmetrization. Aesthetic results were evaluated by three different methods: the patient's self-report, the assessment of four independent specialists (two breast surgeons and two plastic surgeons from different institutions), and the BCCT.core software. Quality of life was evaluated by means of the BREAST-Q instrument. Average age ± SD was 52.1 ± 11.6 years. Most of patients had medium size breasts and T1 tumors. Patients had evaluated their aesthetic results better than did software and specialists. There was no significant difference in the comparison between software and specialist's evaluation. Multifactorial analysis showed that age older than 70 years and radiotherapy were significant risk factors for poor aesthetic outcomes after immediate breast reconstruction with implants. Considering quality of life, most of the patients were satisfied with their outcome and psychosocial and sexual well-being. Immediate breast reconstruction with implants and contralateral symmetrization had a positive impact on the quality of life and showed satisfactory outcomes when evaluated by subjective and objective methods.

  19. Evaluation of School Library Media Centers: Demonstrating Quality.

    ERIC Educational Resources Information Center

    Everhart, Nancy

    2003-01-01

    Discusses ways to evaluate school library media programs and how to demonstrate quality. Topics include how principals evaluate programs; sources of evaluative data; national, state, and local instruments; surveys and interviews; Colorado benchmarks; evaluating the use of electronic resources; and computer reporting options. (LRW)

  20. [Quality assurance in geriatric rehabilitation--approaches and methods].

    PubMed

    Deckenbach, B; Borchelt, M; Steinhagen-Thiessen, E

    1997-08-01

    It did not take the provisions of the 5th Book of the Social Code for quality assurance issues to gain significance in the field of geriatric rehabilitation as well. While in the surgical specialties, experience in particular with external quality assurance have already been gathered over several years now, suitable concepts and methods for the new Geriatric Rehabilitation specialty are still in the initial stages of development. Proven methods from the industrial and service sectors, such as auditing, monitoring and quality circles, can in principle be drawn on for devising geriatric rehabilitation quality assurance schemes; these in particular need to take into account the multiple factors influencing the course and outcome of rehabilitation entailed by multimorbidity and multi-drug use; the eminent role of the social environment; therapeutic interventions by a multidisciplinary team; as well as the multi-dimensional nature of rehabilitation outcomes. Moreover, the specific conditions of geriatric rehabilitation require development not only of quality standards unique to this domain but also of quality assurance procedures specific to geriatrics. Along with a number of other methods, standardized geriatric assessment will play a crucial role in this respect.

  1. Field-based evaluation of a male-specific (F+) RNA coliphage concentration method

    EPA Science Inventory

    Fecal contamination of water poses a significant risk to public health due to the potential presence of pathogens, including enteric viruses. Thus, sensitive, reliable and easy to use methods for the detection of microorganisms are needed to evaluate water quality. In this stud...

  2. METHODOLOGICAL QUALITY OF ECONOMIC EVALUATIONS ALONGSIDE TRIALS OF KNEE PHYSIOTHERAPY.

    PubMed

    García-Pérez, Lidia; Linertová, Renata; Arvelo-Martín, Alejandro; Guerra-Marrero, Carolina; Martínez-Alberto, Carlos Enrique; Cuéllar-Pompa, Leticia; Escobar, Antonio; Serrano-Aguilar, Pedro

    2017-01-01

    The methodological quality of an economic evaluation performed alongside a clinical trial can be underestimated if the paper does not report key methodological features. This study discusses methodological assessment issues on the example of a systematic review on cost-effectiveness of physiotherapy for knee osteoarthritis. Six economic evaluation studies included in the systematic review and related clinical trials were assessed using the 10-question check-list by Drummond and the Physiotherapy Evidence Database (PEDro) scale. All economic evaluations were performed alongside a clinical trial but the studied interventions were too heterogeneous to be synthesized. Methodological quality of the economic evaluations reported in the papers was not free of drawbacks, and in some cases, it improved when information from the related clinical trial was taken into account. Economic evaluation papers dedicate little space to methodological features of related clinical trials; therefore, the methodological quality can be underestimated if evaluated separately from the trials. Future economic evaluations should follow more strictly the recommendations about methodology and the authors should pay special attention to the quality of reporting.

  3. Research on Air Quality Evaluation based on Principal Component Analysis

    NASA Astrophysics Data System (ADS)

    Wang, Xing; Wang, Zilin; Guo, Min; Chen, Wei; Zhang, Huan

    2018-01-01

    Economic growth has led to environmental capacity decline and the deterioration of air quality. Air quality evaluation as a fundamental of environmental monitoring and air pollution control has become increasingly important. Based on the principal component analysis (PCA), this paper evaluates the air quality of a large city in Beijing-Tianjin-Hebei Area in recent 10 years and identifies influencing factors, in order to provide reference to air quality management and air pollution control.

  4. Evaluating the Quality of the Child Care in Finland

    ERIC Educational Resources Information Center

    Hujala, Eeva; Fonsen, Elina; Elo, Janniina

    2012-01-01

    In this study we examine parents' and teachers' perceptions of the early childhood education and care (ECEC) quality in Finland. The study is based on the paradigm of inclusionary quality and the assessment is based on the quality evaluation model. The parents and teachers assess the quality to be good. The strength of the quality was the effect…

  5. Human action quality evaluation based on fuzzy logic with application in underground coal mining.

    PubMed

    Ionica, Andreea; Leba, Monica

    2015-01-01

    The work system is defined by its components, their roles and the relationships between them. Any work system gravitates around the human resource and the interdependencies between human factor and the other components of it. Researches in this field agreed that the human factor and its actions are difficult to quantify and predict. The objective of this paper is to apply a method of human actions evaluation in order to estimate possible risks and prevent possible system faults, both at human factor level and at equipment level. In order to point out the importance of the human factor influence on all the elements of the working systems we propose a fuzzy logic based methodology for quality evaluation of human actions. This methodology has a multidisciplinary character, as it gathers ideas and methods from: quality management, ergonomics, work safety and artificial intelligence. The results presented refer to a work system with a high degree of specificity, namely, underground coal mining and are valuable for human resources risk evaluation pattern. The fuzzy logic evaluation of the human actions leads to early detection of possible dangerous evolutions of the work system and alarm the persons in charge.

  6. Structured implicit review: a new method for monitoring nursing care quality.

    PubMed

    Pearson, M L; Lee, J L; Chang, B L; Elliott, M; Kahn, K L; Rubenstein, L V

    2000-11-01

    Nurses' independent decisions about assessment, treatment, and nursing interventions for hospitalized patients are important determinants of quality of care. Physician peer implicit review of medical records has been central to Medicare quality management and is considered the gold standard for reviewing physician care, but peer implicit review of nursing processes of care has not received similar attention. The objective of this study was to develop and evaluate nurse structured implicit review (SIR) methods. We developed SIR instruments for rating the quality of inpatient nursing care for congestive heart failure (CHF) and cerebrovascular accident (CVA). Nurse reviewers used the SIR form to rate a nationally representative sample of randomly selected medical records for each disease from 297 acute care hospitals in 5 states (collected by the RAND-HCFA Prospective Payment System study). The study subjects were elderly Medicare inpatients with CHF (n = 291) or CVA (n = 283). We developed and tested scales reflecting domains of nursing process, evaluated interrater and interitem reliability, and assessed the extent to which items and scales predicted overall ratings of the quality of nursing care. Interrater reliability for 14 of 16 scales (CHF) or 10 of 16 scales (CVA) was > or = 0.40. Interitem reliability was > 0.80 for all but 1 scale (both diseases). Functional Assessment, Physical Assessment, and Medication Tracking ratings were the strongest predictors of overall nursing quality ratings (P < 0.001 for each). Nurse peer review with SIR has adequate interrater and excellent scale reliabilities and can be a valuable tool for assessing nurse performance.

  7. Dynamic Evaluation of Regional Air Quality Model's Response to Emission Reductions in the Presence of Uncertain Emission Inventories

    EPA Science Inventory

    A method is presented and applied for evaluating an air quality model’s changes in pollutant concentrations stemming from changes in emissions while explicitly accounting for the uncertainties in the base emission inventory. Specifically, the Community Multiscale Air Quality (CMA...

  8. Method Optimization for Extracting High-Quality RNA From the Human Pancreas Tissue.

    PubMed

    Jun, Eunsung; Oh, Juyun; Lee, Song; Jun, Hye-Ryeong; Seo, Eun Hye; Jang, Jin-Young; Kim, Song Cheol

    2018-06-01

    Nucleic acid sequencing is frequently used to determine the molecular basis of diseases. Therefore, proper storage of biological specimens is essential to inhibit nucleic acid degradation. RNA isolated from the human pancreas is generally of poor quality because of its high concentration of endogenous RNase. In this study, we optimized the method for extracting high quality RNA from paired tumor and normal pancreatic tissues obtained from eight pancreatic cancer patients post-surgery. RNA integrity number (RIN) was checked to evaluate the integrity of RNA, we tried to extract the RNA with an RIN value of 8 or higher that allows for the latest genetic analysis. The effect of several parameters, including the method used for tissue lysis, RNAlater treatment, tissue weight at storage, and the time to storage after surgical resection, on the quantity and quality of RNA extracted was examined. Data showed that the highest quantity of RNA was isolated using a combination of manual and mechanical methods of tissue lysis. Additionally, sectioning the tissues into small pieces (<100 mg) and treating them with RNAlater solution prior to storage increased RNA stability. Following these guidelines, high quality RNA was obtained from 100% (8/8) of tumor tissues and 75% (6/8) of normal tissues. High-quality RNA was still stable under repeated freezing and thawing. The application of these results during sample handling and storage in clinical settings will facilitate the genetic diagnosis of diseases and their subsequent treatment. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  9. Light-leaking region segmentation of FOG fiber based on quality evaluation of infrared image

    NASA Astrophysics Data System (ADS)

    Liu, Haoting; Wang, Wei; Gao, Feng; Shan, Lianjie; Ma, Yuzhou; Ge, Wenqian

    2014-07-01

    To improve the assembly reliability of Fiber Optic Gyroscope (FOG), a light leakage detection system and method is developed. First, an agile movement control platform is designed to implement the pose control of FOG optical path component in 6 Degrees of Freedom (DOF). Second, an infrared camera is employed to capture the working state images of corresponding fibers in optical path component after the manual assembly of FOG; therefore the entire light transmission process of key sections in light-path can be recorded. Third, an image quality evaluation based region segmentation method is developed for the light leakage images. In contrast to the traditional methods, the image quality metrics, including the region contrast, the edge blur, and the image noise level, are firstly considered to distinguish the image characters of infrared image; then the robust segmentation algorithms, including graph cut and flood fill, are all developed for region segmentation according to the specific image quality. Finally, after the image segmentation of light leakage region, the typical light-leaking type, such as the point defect, the wedge defect, and the surface defect can be identified. By using the image quality based method, the applicability of our proposed system can be improved dramatically. Many experiment results have proved the validity and effectiveness of this method.

  10. Economic Evaluation of Obesity Prevention in Early Childhood: Methods, Limitations and Recommendations.

    PubMed

    Döring, Nora; Mayer, Susanne; Rasmussen, Finn; Sonntag, Diana

    2016-09-13

    Despite methodological advances in the field of economic evaluations of interventions, economic evaluations of obesity prevention programmes in early childhood are seldom conducted. The aim of the present study was to explore existing methods and applications of economic evaluations, examining their limitations and making recommendations for future cost-effectiveness assessments. A systematic literature search was conducted using PubMed, Cochrane Library, the British National Health Service Economic Evaluation Databases and EconLit. Eligible studies included trial-based or simulation-based cost-effectiveness analyses of obesity prevention programmes targeting preschool children and/or their parents. The quality of included studies was assessed. Of the six studies included, five were intervention studies and one was based on a simulation approach conducted on secondary data. We identified three main conceptual and methodological limitations of their economic evaluations: Insufficient conceptual approach considering the complexity of childhood obesity, inadequate measurement of effects of interventions, and lack of valid instruments to measure child-related quality of life and costs. Despite the need for economic evaluations of obesity prevention programmes in early childhood, only a few studies of varying quality have been conducted. Moreover, due to methodological and conceptual weaknesses, they offer only limited information for policy makers and intervention providers. We elaborate reasons for the limitations of these studies and offer guidance for designing better economic evaluations of early obesity prevention.

  11. Economic Evaluation of Obesity Prevention in Early Childhood: Methods, Limitations and Recommendations

    PubMed Central

    Döring, Nora; Mayer, Susanne; Rasmussen, Finn; Sonntag, Diana

    2016-01-01

    Despite methodological advances in the field of economic evaluations of interventions, economic evaluations of obesity prevention programmes in early childhood are seldom conducted. The aim of the present study was to explore existing methods and applications of economic evaluations, examining their limitations and making recommendations for future cost-effectiveness assessments. A systematic literature search was conducted using PubMed, Cochrane Library, the British National Health Service Economic Evaluation Databases and EconLit. Eligible studies included trial-based or simulation-based cost-effectiveness analyses of obesity prevention programmes targeting preschool children and/or their parents. The quality of included studies was assessed. Of the six studies included, five were intervention studies and one was based on a simulation approach conducted on secondary data. We identified three main conceptual and methodological limitations of their economic evaluations: Insufficient conceptual approach considering the complexity of childhood obesity, inadequate measurement of effects of interventions, and lack of valid instruments to measure child-related quality of life and costs. Despite the need for economic evaluations of obesity prevention programmes in early childhood, only a few studies of varying quality have been conducted. Moreover, due to methodological and conceptual weaknesses, they offer only limited information for policy makers and intervention providers. We elaborate reasons for the limitations of these studies and offer guidance for designing better economic evaluations of early obesity prevention. PMID:27649218

  12. Evaluating Air-Quality Models: Review and Outlook.

    NASA Astrophysics Data System (ADS)

    Weil, J. C.; Sykes, R. I.; Venkatram, A.

    1992-10-01

    Over the past decade, much attention has been devoted to the evaluation of air-quality models with emphasis on model performance in predicting the high concentrations that are important in air-quality regulations. This paper stems from our belief that this practice needs to be expanded to 1) evaluate model physics and 2) deal with the large natural or stochastic variability in concentration. The variability is represented by the root-mean- square fluctuating concentration (c about the mean concentration (C) over an ensemble-a given set of meteorological, source, etc. conditions. Most air-quality models used in applications predict C, whereas observations are individual realizations drawn from an ensemble. For cC large residuals exist between predicted and observed concentrations, which confuse model evaluations.This paper addresses ways of evaluating model physics in light of the large c the focus is on elevated point-source models. Evaluation of model physics requires the separation of the mean model error-the difference between the predicted and observed C-from the natural variability. A residual analysis is shown to be an elective way of doing this. Several examples demonstrate the usefulness of residuals as well as correlation analyses and laboratory data in judging model physics.In general, c models and predictions of the probability distribution of the fluctuating concentration (c), (c, are in the developmental stage, with laboratory data playing an important role. Laboratory data from point-source plumes in a convection tank show that (c approximates a self-similar distribution along the plume center plane, a useful result in a residual analysis. At pmsent,there is one model-ARAP-that predicts C, c, and (c for point-source plumes. This model is more computationally demanding than other dispersion models (for C only) and must be demonstrated as a practical tool. However, it predicts an important quantity for applications- the uncertainty in the very high and

  13. Quality Control Guidelines for SAM Chemical Methods

    EPA Pesticide Factsheets

    Learn more about quality control guidelines and recommendations for the analysis of samples using the chemistry methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  14. Quality Control Guidelines for SAM Radiochemical Methods

    EPA Pesticide Factsheets

    Learn more about quality control guidelines and recommendations for the analysis of samples using the radiochemistry methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  15. Quality Control Guidelines for SAM Biotoxin Methods

    EPA Pesticide Factsheets

    Learn more about quality control guidelines and recommendations for the analysis of samples using the pathogen methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  16. Quality Control Guidelines for SAM Pathogen Methods

    EPA Pesticide Factsheets

    Learn more about quality control guidelines and recommendations for the analysis of samples using the biotoxin methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  17. A Comparative Evaluation of Analytical Methods to Allocate Individual Marks from a Team Mark

    ERIC Educational Resources Information Center

    Nepal, Kali

    2012-01-01

    This study presents a comparative evaluation of analytical methods to allocate individual marks from a team mark. Only the methods that use or can be converted into some form of mathematical equations are analysed. Some of these methods focus primarily on the assessment of the quality of teamwork product (product assessment) while the others put…

  18. A new method of regional eco-environmental quality assessment and its application.

    PubMed

    Wang, Xiaodan; Cao, Yingzi; Zhong, Xianghao; Gao, Pan

    2012-01-01

    Eco-environmental quality assessment (EQA) is an intricate and challenging task that must take into account numerous natural, economic, political, and social factors, which are subject to multiple conflicting criteria. In this paper, a methodological reference framework is developed for EQA that combines the fuzzy Delphi method (FDM) and fuzzy analytical hierarchy process (FAHP) with a geographic information system (GIS). The proposed method significantly improves the accuracy and reliability of evaluation results through the incorporation of fuzzy set theory. A GIS not only has the ability to store and analyze large amounts of spatial data from different sources but also provides a consistent visualization environment for displaying the input data and the results of EQA. Furthermore, unlike prior EQAs, the proposed method can support the dynamic estimation of regional eco-environmental quality by updating historical spatiotemporal data at little additional cost. A case study is presented for the western Tibetan Plateau. The study results show that worse, bad, and moderate eco-environmental quality classes comprised 16.58, 20.15, and 24.84% of the total area, respectively. Good and better eco-environmental quality classes accounted for 38.43%. This result indicates that nearly 62% of the total area is eco-environmentally vulnerable. The results verified the usefulness and feasibility of the proposed method. The EQA can also help local managers make scientifically based and effective decisions about Tibetan eco-environmental protection and land use. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  19. Evaluating Quality in Educational Facilities

    ERIC Educational Resources Information Center

    Abend, Allen; Ornstein, Sheila Walbe; Baltas, Emmanuel; de la Garza, Jaime; Watson, Chris; Lange, Kurt; von Ahlefeld, Hannah

    2006-01-01

    In 2005, the OECD Programme on Educational Building (PEB) organised two international experts' group meetings to discuss how countries define and evaluate quality in educational facilities. The research and experiences of six experts are presented in this article, in addition to the lessons learned from the experts' group meetings. The director of…

  20. Evaluation of angiogram visualization methods for fast and reliable aneurysm diagnosis

    NASA Astrophysics Data System (ADS)

    Lesar, Žiga; Bohak, Ciril; Marolt, Matija

    2015-03-01

    In this paper we present the results of an evaluation of different visualization methods for angiogram volumetric data-ray casting, marching cubes, and multi-level partition of unity implicits. There are several options available with ray-casting: isosurface extraction, maximum intensity projection and alpha compositing, each producing fundamentally different results. Different visualization methods are suitable for different needs, so this choice is crucial in diagnosis and decision making processes. We also evaluate visual effects such as ambient occlusion, screen space ambient occlusion, and depth of field. Some visualization methods include transparency, so we address the question of relevancy of this additional visual information. We employ transfer functions to map data values to color and transparency, allowing us to view or hide particular tissues. All the methods presented in this paper were developed using OpenCL, striving for real-time rendering and quality interaction. An evaluation has been conducted to assess the suitability of the visualization methods. Results show superiority of isosurface extraction with ambient occlusion effects. Visual effects may positively or negatively affect perception of depth, motion, and relative positions in space.

  1. Research on uncertainty evaluation measure and method of voltage sag severity

    NASA Astrophysics Data System (ADS)

    Liu, X. N.; Wei, J.; Ye, S. Y.; Chen, B.; Long, C.

    2018-01-01

    Voltage sag is an inevitable serious problem of power quality in power system. This paper focuses on a general summarization and reviews on the concepts, indices and evaluation methods about voltage sag severity. Considering the complexity and uncertainty of influencing factors, damage degree, the characteristics and requirements of voltage sag severity in the power source-network-load sides, the measure concepts and their existing conditions, evaluation indices and methods of voltage sag severity have been analyzed. Current evaluation techniques, such as stochastic theory, fuzzy logic, as well as their fusion, are reviewed in detail. An index system about voltage sag severity is provided for comprehensive study. The main aim of this paper is to propose thought and method of severity research based on advanced uncertainty theory and uncertainty measure. This study may be considered as a valuable guide for researchers who are interested in the domain of voltage sag severity.

  2. Bubble structure evaluation method of sponge cake by using image morphology

    NASA Astrophysics Data System (ADS)

    Kato, Kunihito; Yamamoto, Kazuhiko; Nonaka, Masahiko; Katsuta, Yukiyo; Kasamatsu, Chinatsu

    2007-01-01

    Nowadays, many evaluation methods for food industry by using image processing are proposed. These methods are becoming new evaluation method besides the sensory test and the solid-state measurement that have been used for the quality evaluation recently. The goal of our research is structure evaluation of sponge cake by using the image processing. In this paper, we propose a feature extraction method of the bobble structure in the sponge cake. Analysis of the bubble structure is one of the important properties to understand characteristics of the cake from the image. In order to take the cake image, first we cut cakes and measured that's surface by using the CIS scanner, because the depth of field of this type scanner is very shallow. Therefore the bubble region of the surface has low gray scale value, and it has a feature that is blur. We extracted bubble regions from the surface images based on these features. The input image is binarized, and the feature of bubble is extracted by the morphology analysis. In order to evaluate the result of feature extraction, we compared correlation with "Size of the bubble" of the sensory test result. From a result, the bubble extraction by using morphology analysis gives good correlation. It is shown that our method is as well as the subjectivity evaluation.

  3. Evaluating methods of mouse euthanasia on the oocyte quality: cervical dislocation versus isoflurane inhalation.

    PubMed

    Roustan, Audrey; Perrin, Jeanne; Berthelot-Ricou, Anaïs; Lopez, Erica; Botta, Alain; Courbiere, Blandine

    2012-04-01

    Cervical dislocation is a commonly used method of mouse euthanasia. Euthanasia by isoflurane inhalation is an alternative method which allows the sacrifice of several mice at the same time with an anaesthesia, in the aim to decrease pain and animal distress. The objective of our study was to assess the impact of these two methods of euthanasia on the quality of mouse oocytes. By administering gonadotropins, we induced a superovulation in CD1 female mice. Mice were randomly assigned to euthanasia with cervical dislocation and isoflurane inhalation. Oviducts were collected and excised to retrieve metaphase II oocytes. After microscopic examination, oocytes were classified into three groups: intact, fragmented/cleaved and atretic. Intact metaphase II oocytes were employed for biomedical research. A total of 1442 oocytes in the cervical dislocation group were compared with 1230 oocytes in the isoflurane group. In the cervical dislocation group, 93.1% of the oocytes were intact, versus 65.8% in the isoflurane group (P ≤ 0.001). In light of these results, we conclude that cervical dislocation is the best method of mouse euthanasia for obtaining intact oocytes for biomedical research.

  4. An Investigation to Improve Quality Evaluations of Primers and Propellant for 20mm Munitions

    NASA Technical Reports Server (NTRS)

    Bement, L. J.; Holmes, C.; McGrory, J.; Schimmel, M. L.

    1997-01-01

    To reduce the frequency of electrically initiated, 20mm munition hangfires (delayed ignitions), a joint Army/NASA investigation was conducted to recommend quality evaluation improvements for acceptance of both primers and gun propellant. This effort focused only on evaluating ignition and combustion performance as potential causes of hangfires: poor electrical initiation of the primer, low output performance of the primer, low ignition sensitivity of the gun propellant, and the effects of cold temperature. The goal was to determine the "best" of the Army and NASA test methods to assess the functional performance of primers and gun propellants. The approach was to evaluate the performance of both high-quality and deliberately defective primers to challenge the sensitivity of test methods. In addition, the ignition sensitivity of different manufacturing batches of gun propellants was evaluated. The results of the investigation revealed that improvements can be made in functional evaluations that can assist in identifying and reducing ignition and performance variations. The "best" functional evaluation of primers and propellant is achieved through a combination of both Army and NASA test methods. Incorporating the recommendations offered in this report may provide for considerable savings in reducing the number of cartridge firings, while significantly lowering the rejection rate of primer, propellant and cartridge lots. The most probable causes for ignition and combustion-related hangfires were the lack of calcium silicide in the primer mix, a low output performance of primers, and finally, poor ignition sensitivity of gun propellant. Cold temperatures further reduce propellant ignition sensitivity, as well as reducing burn rate and chamber pressures.

  5. Validation of a two-dimensional liquid chromatography method for quality control testing of pharmaceutical materials.

    PubMed

    Yang, Samuel H; Wang, Jenny; Zhang, Kelly

    2017-04-07

    Despite the advantages of 2D-LC, there is currently little to no work in demonstrating the suitability of these 2D-LC methods for use in a quality control (QC) environment for good manufacturing practice (GMP) tests. This lack of information becomes more critical as the availability of commercial 2D-LC instrumentation has significantly increased, and more testing facilities begin to acquire these 2D-LC capabilities. It is increasingly important that the transferability of developed 2D-LC methods be assessed in terms of reproducibility, robustness and performance across different laboratories worldwide. The work presented here focuses on the evaluation of a heart-cutting 2D-LC method used for the analysis of a pharmaceutical material, where a key, co-eluting impurity in the first dimension ( 1 D) is resolved from the main peak and analyzed in the second dimension ( 2 D). A design-of-experiments (DOE) approach was taken in the collection of the data, and the results were then modeled in order to evaluate method robustness using statistical modeling software. This quality by design (QBD) approach gives a deeper understanding of the impact of these 2D-LC critical method attributes (CMAs) and how they affect overall method performance. Although there are multiple parameters that may be critical from method development point of view, a special focus of this work is devoted towards evaluation of unique 2D-LC critical method attributes from method validation perspective that transcend conventional method development and validation. The 2D-LC method attributes are evaluated for their recovery, peak shape, and resolution of the two co-eluting compounds in question on the 2 D. In the method, linearity, accuracy, precision, repeatability, and sensitivity are assessed along with day-to-day, analyst-to-analyst, and lab-to-lab (instrument-to-instrument) assessments. The results of this validation study demonstrate that the 2D-LC method is accurate, sensitive, and robust and is

  6. Programme Evaluation: Maintaining Quality in Higher Education

    ERIC Educational Resources Information Center

    Loots, A.

    2008-01-01

    The evaluation of educational or social programmes is paramount for establishing success or impact in higher education. Evaluation questions about programme goals (e.g. better performance of first-year students) or about the quality of programme strategies (design and implementation) and effectiveness of delivery (coordinator inputs and…

  7. Evaluation of the quality of the teaching-learning process in undergraduate courses in Nursing 1

    PubMed Central

    González-Chordá, Víctor Manuel; Maciá-Soler, María Loreto

    2015-01-01

    Abstract Objective: to identify aspects of improvement of the quality of the teaching-learning process through the analysis of tools that evaluated the acquisition of skills by undergraduate students of Nursing. Method: prospective longitudinal study conducted in a population of 60 secondyear Nursing students based on registration data, from which quality indicators that evaluate the acquisition of skills were obtained, with descriptive and inferential analysis. Results: nine items were identified and nine learning activities included in the assessment tools that did not reach the established quality indicators (p<0.05). There are statistically significant differences depending on the hospital and clinical practices unit (p<0.05). Conclusion: the analysis of the evaluation tools used in the article "Nursing Care in Welfare Processes" of the analyzed university undergraduate course enabled the detection of the areas for improvement in the teachinglearning process. The challenge of education in nursing is to reach the best clinical research and educational results, in order to provide improvements to the quality of education and health care. PMID:26444173

  8. A review of economic evaluations of behavior change interventions: setting an agenda for research methods and practice.

    PubMed

    Alayli-Goebbels, Adrienne F G; Evers, Silvia M A A; Alexeeva, Daria; Ament, André J H A; de Vries, Nanne K; Tilly, Jan C; Severens, Johan L

    2014-06-01

    The objective of this study was to review methodological quality of economic evaluations of lifestyle behavior change interventions (LBCIs) and to examine how they address methodological challenges for public health economic evaluation identified in the literature. Pubmed and the NHS economic evaluation database were searched for published studies in six key areas for behavior change: smoking, physical activity, dietary behavior, (illegal) drug use, alcohol use and sexual behavior. From included studies (n = 142), we extracted data on general study characteristics, characteristics of the LBCIs, methodological quality and handling of methodological challenges. Economic evaluation evidence for LBCIs showed a number of weaknesses: methods, study design and characteristics of evaluated interventions were not well reported; methodological quality showed several shortcomings and progress with addressing methodological challenges remained limited. Based on the findings of this review we propose an agenda for improving future evidence to support decision-making. Recommendations for practice include improving reporting of essential study details and increasing adherence with good practice standards. Recommendations for research methods focus on mapping out complex causal pathways for modeling, developing measures to capture broader domains of wellbeing and community outcomes, testing methods for considering equity, identifying relevant non-health sector costs and advancing methods for evidence synthesis. © The Author 2013. Published by Oxford University Press on behalf of Faculty of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  9. Pancreatitis Quality of Life Instrument: A Psychometric Evaluation.

    PubMed

    Wassef, Wahid; DeWitt, John; McGreevy, Kathleen; Wilcox, Mel; Whitcomb, David; Yadav, Dhiraj; Amann, Stephen; Mishra, Girish; Alkaade, Samer; Romagnuolo, Joseph; Stevens, Tyler; Vargo, John; Gardner, Timothy; Singh, Vikesh; Park, Walter; Hartigan, Celia; Barton, Bruce; Bova, Carol

    2016-08-01

    Chronic pancreatitis is a significant medical problem that impacts a large number of patients worldwide. In 2014, we developed a disease-specific instrument for the evaluation of quality of life in this group of patients: pancreatitis quality of life instrument (PANQOLI). The goal of this study was to evaluate its psychometric properties: its reliability and its construct validity. This is a cross-sectional multi-center study that involved 12 pancreatic disease centers. Patients who met the inclusion/exclusion criteria for chronic pancreatitis were invited to participate. Those who accepted were asked to complete seven questionnaires/instruments. Only patients who completed the PANQOLI were included in the study. Its reliability and its construct validity were tested. A total of 159 patients completed the PANQOLI and were included in the study. They had a mean age of 49.03, 49% were male, and 84% were Caucasian. Six of the 24 items on the scale were removed because of lack of inter-item correlation, redundancy, or lack of correlation to quality of life issues. The final 18-item scale had excellent reliability (Cronbach's alpha coefficient: 0.914) and excellent construct validity with good correlation to generic quality of life instruments (SF-12 and EORTC QLQ-C30/QLQ-PAN26) and lack of correlation to non-quality of life instruments (MAST and DAST). Through exploratory factor analysis, the PANQOLI was found to consist of four subscales: emotional function scale, role function scale, physical function scale, and "self-worth" scale. PANQOLI is the first disease-specific instrument to be developed and validated for the evaluation of quality of life in chronic pancreatitis patients. It has a unique subscale for "self-worth" that differentiates it from other generic instruments. Studies are currently under way to evaluate its use in other populations not included in this study.

  10. Teaching Evaluation: A Critical Measure for Improving the Quality of Education

    ERIC Educational Resources Information Center

    Ji, Zhou

    2009-01-01

    In the coming period, the main task for China's higher education system is to improve the quality of education, and the key to improving the quality of education is to improve the quality of teaching. Teaching evaluations are a critical measure for improving the quality of teaching. The work of evaluating teaching at institutions of higher…

  11. Using the Cross-Correlation Function to Evaluate the Quality of Eddy-Covariance Data

    NASA Astrophysics Data System (ADS)

    Qi, Yongfeng; Shang, Xiaodong; Chen, Guiying; Gao, Zhiqiu; Bi, Xueyan

    2015-11-01

    A cross-correlation test is proposed for evaluating the quality of 30-min eddy-covariance data. Cross-correlation as a function of time lag is computed for vertical velocity paired with temperature, humidity, and carbon dioxide concentration. High quality data have a dominant peak at zero time lag and approach zero within a time lag of 20 s. Poor quality data have erratic cross-correlation functions, which indicates that the eddy flux may no longer represent the energy and mass exchange between the atmospheric surface layer and the canopy, and such data should be rejected in post-data analyses. Eddy-covariance data over grassland in July 2004 are used to evaluate the proposed test. The results show that 17, 29, and 36 % of the available data should be rejected because of poor quality measurements of sensible heat, latent heat, and CO2 fluxes, respectively. The rejected data mainly occurred on calm nights and day/night transitions when the atmospheric surface layer became stable or neutrally stratified. We found no friction velocity (u_*) threshold below which all data should be rejected, a test that many other studies have implemented for rejecting questionable data. We instead found that some data with low u_* were reliable, whereas other data with higher u_* were not. The poor quality measurements collected under less than ideal conditions were replaced by using the mean diurnal variation gap-filling method. The correction for poor quality data shifted the daily average CO2 flux by +0.34 g C m^{-2} day^{-1}. After applying the quality-control test, the eddy CO2 fluxes did not display a clear dependence on u_*. The results suggest that the cross-correlation test is a potentially valuable step in evaluating the quality of eddy-covariance data.

  12. [Care quality in intensive care evaluated by the patients using a service quality scale (SERVQUAL)].

    PubMed

    Regaira Martínez, E; Sola Iriarte, M; Goñi Viguria, R; Del Barrio Linares, M; Margall Coscojuela, M A; Asiain Erro, M C

    2010-01-01

    The evaluation made by the patients on the quality of service received is important to introduce improvement strategies in the care quality. 1. To evaluate the care quality through the analysis of the differences obtained between expectations and perceptions, that the patients have of the service received in the ICU. 2. To analyze if there is any relationship between care quality evaluated by the patients and the sociodemographic variables. A total of 86 patients who were conscious and oriented during their stay in the ICU were studied prospectively. At 24h of the discharge from the ICU, the SERVQUAL (Service Quality) scale, adapted for the hospital setting by Babakus and Mangold (1992), was applied. This scale measures the care quality based on the difference in scores obtained between expectations and perceptions of the patients. The positive scores indicate that the perceptions of the patients exceed their expectations. The scale has 5 dimensions: Tangibility, Reliability, Responsiveness, Assurances and Empathy. It includes 15 items for perceptions and the same for expectations, with 5 grades of response (1 totally disagree - 5 totally agree). The mean score of perceptions 66.92) exceeded that of the expectations (62.30). The mean score of the difference between perceptions and expectations for the total of the SERVQUAL scale was 4.62. It was also positive for each one of the dimensions: Tangibility=1.44, Reliability=0.53, Responsiveness=0.95, Assurances=0.99, Empathy=0.71. No statistically significant associations were found between care quality evaluated by the patients and the sociodemographic variables. The care quality perceived by the patients in the ICU exceeds their expectations, and had no relationship with the sociodemographic characteristics. Copyright 2009 Elsevier España, S.L. y SEEIUC. All rights reserved.

  13. Groundwater quality assessment of the quaternary unconsolidated sedimentary basin near the Pi river using fuzzy evaluation technique

    NASA Astrophysics Data System (ADS)

    Mohamed, Adam Khalifa; Liu, Dan; Mohamed, Mohamed A. A.; Song, Kai

    2018-05-01

    The present study was carried out to assess the groundwater quality for drinking purposes in the Quaternary Unconsolidated Sedimentary Basin of the North Chengdu Plain, China. Six groups of water samples (S1, S2, S3, S4, S5, and S6) are selected in the study area. These samples were analyzed for 19 different physicochemical water quality parameters to assess groundwater quality. The physicochemical parameters of groundwater were compared with China's Quality Standards for Groundwater (GB/T14848-93). Interpretation of physicochemical data revealed that groundwater in the basin was slightly alkaline. Total hardness and total dissolved solid values show that the investigated water is classified as very hard and fresh water, respectively. The sustainability of groundwater for drinking purposes was assessed based on the fuzzy mathematics evaluation (FME) method. The results of the assessment were classified into five groups based on their relative suitability for portable use (grade I = most suitable to grade V = least suitable), according to (GB/T 14848-93). The assessment results reveal that the quality of groundwater in most of the wells was class I, II and III and suitable for drinking purposes, but well (S2) has been found to be in class V, which is classified as very poor and cannot be used for drinking. Also, the FME method was compared with the comprehensive evaluation method. The FME method was found to be more comprehensive and reasonable to assess groundwater quality. This study can provide an important frame of reference for decision making on improving groundwater quality in the study area and nearby surrounding.

  14. Using a fuzzy comprehensive evaluation method to determine product usability: A test case.

    PubMed

    Zhou, Ronggang; Chan, Alan H S

    2017-01-01

    In order to take into account the inherent uncertainties during product usability evaluation, Zhou and Chan [1] proposed a comprehensive method of usability evaluation for products by combining the analytic hierarchy process (AHP) and fuzzy evaluation methods for synthesizing performance data and subjective response data. This method was designed to provide an integrated framework combining the inevitable vague judgments from the multiple stages of the product evaluation process. In order to illustrate the effectiveness of the model, this study used a summative usability test case to assess the application and strength of the general fuzzy usability framework. To test the proposed fuzzy usability evaluation framework [1], a standard summative usability test was conducted to benchmark the overall usability of a specific network management software. Based on the test data, the fuzzy method was applied to incorporate both the usability scores and uncertainties involved in the multiple components of the evaluation. Then, with Monte Carlo simulation procedures, confidence intervals were used to compare the reliabilities among the fuzzy approach and two typical conventional methods combining metrics based on percentages. This case study showed that the fuzzy evaluation technique can be applied successfully for combining summative usability testing data to achieve an overall usability quality for the network software evaluated. Greater differences of confidence interval widths between the method of averaging equally percentage and weighted evaluation method, including the method of weighted percentage averages, verified the strength of the fuzzy method.

  15. Softcopy quality ruler method: implementation and validation

    NASA Astrophysics Data System (ADS)

    Jin, Elaine W.; Keelan, Brian W.; Chen, Junqing; Phillips, Jonathan B.; Chen, Ying

    2009-01-01

    A softcopy quality ruler method was implemented for the International Imaging Industry Association (I3A) Camera Phone Image Quality (CPIQ) Initiative. This work extends ISO 20462 Part 3 by virtue of creating reference digital images of known subjective image quality, complimenting the hardcopy Standard Reference Stimuli (SRS). The softcopy ruler method was developed using images from a Canon EOS 1Ds Mark II D-SLR digital still camera (DSC) and a Kodak P880 point-and-shoot DSC. Images were viewed on an Apple 30in Cinema Display at a viewing distance of 34 inches. Ruler images were made for 16 scenes. Thirty ruler images were generated for each scene, representing ISO 20462 Standard Quality Scale (SQS) values of approximately 2 to 31 at an increment of one just noticeable difference (JND) by adjusting the system modulation transfer function (MTF). A Matlab GUI was developed to display the ruler and test images side-by-side with a user-adjustable ruler level controlled by a slider. A validation study was performed at Kodak, Vista Point Technology, and Aptina Imaging in which all three companies set up a similar viewing lab to run the softcopy ruler method. The results show that the three sets of data are in reasonable agreement with each other, with the differences within the range expected from observer variability. Compared to previous implementations of the quality ruler, the slider-based user interface allows approximately 2x faster assessments with 21.6% better precision.

  16. Local motion-compensated method for high-quality 3D coronary artery reconstruction

    PubMed Central

    Liu, Bo; Bai, Xiangzhi; Zhou, Fugen

    2016-01-01

    The 3D reconstruction of coronary artery from X-ray angiograms rotationally acquired on C-arm has great clinical value. While cardiac-gated reconstruction has shown promising results, it suffers from the problem of residual motion. This work proposed a new local motion-compensated reconstruction method to handle this issue. An initial image was firstly reconstructed using a regularized iterative reconstruction method. Then a 3D/2D registration method was proposed to estimate the residual vessel motion. Finally, the residual motion was compensated in the final reconstruction using the extended iterative reconstruction method. Through quantitative evaluation, it was found that high-quality 3D reconstruction could be obtained and the result was comparable to state-of-the-art method. PMID:28018741

  17. A new four-step hierarchy method for combined assessment of groundwater quality and pollution.

    PubMed

    Zhu, Henghua; Ren, Xiaohua; Liu, Zhizheng

    2017-12-28

    A new four-step hierarchy method was constructed and applied to evaluate the groundwater quality and pollution of the Dagujia River Basin. The assessment index system is divided into four types: field test indices, common inorganic chemical indices, inorganic toxicology indices, and trace organic indices. Background values of common inorganic chemical indices and inorganic toxicology indices were estimated with the cumulative-probability curve method, and the results showed that the background values of Mg 2+ (51.1 mg L -1 ), total hardness (TH) (509.4 mg L -1 ), and NO 3 - (182.4 mg L -1 ) are all higher than the corresponding grade III values of Quality Standard for Groundwater, indicating that they were poor indicators and therefore were not included in the groundwater quality assessment. The quality assessment results displayed that the field test indices were mainly classified as grade II, accounting for 60.87% of wells sampled. The indices of common inorganic chemical and inorganic toxicology were both mostly in the range of grade III, whereas the trace organic indices were predominantly classified as grade I. The variabilities and excess ratios of the indices were also calculated and evaluated. Spatial distributions showed that the groundwater with poor quality indices was mainly located in the northeast of the basin, which was well-connected with seawater intrusion. Additionally, the pollution assessment revealed that groundwater in well 44 was classified as "moderately polluted," wells 5 and 8 were "lightly polluted," and other wells were classified as "unpolluted."

  18. Evaluation of a Quality Improvement Resource for Public Health Practitioners

    PubMed Central

    Marcial, Laura H.; Brown, Stephen; Throop, Cynthia; Pina, Jamie

    2017-01-01

    Objectives: Quality improvement is a critical mechanism to manage public health agency performance and to strengthen accountability for public funds. The objective of this study was to evaluate a relatively new quality improvement resource, the Public Health Quality Improvement Exchange (PHQIX), a free online communication platform dedicated to making public health quality improvement information accessible to practitioners. Methods: We conducted an internet-based survey of registered PHQIX users (n = 536 respondents) in 2013 and key informant interviews with PHQIX frequent users (n = 21) in 2014, in the United States. We assessed use of the PHQIX website, user engagement and satisfaction, communication and knowledge exchange, use of information, and impact on quality improvement capacity and accreditation readiness. Results: Of 462 respondents, 369 (79.9%) browsed quality improvement initiatives, making it the most commonly used site feature, and respondents described PHQIX as a near-unique source for real-world quality improvement examples. Respondents were satisfied with the quality and breadth of topics and relevance to their settings (average satisfaction scores, 3.9-4.1 [where 5 was the most satisfied]). Of 407 respondents, 237 (58.2%) said that they had put into practice information learned on PHQIX, and 209 of 405 (51.6%) said that PHQIX had helped to improve quality improvement capacity. Fewer than half of respondents used the commenting function, the Community Forum, and the Ask an Expert feature. Conclusions: Findings suggest that PHQIX, particularly descriptions of the quality improvement initiatives, is a valued resource for public health practitioners. Users reported sharing information with colleagues and applying what they learned to their own work. These findings may relate to other efforts to disseminate quality improvement knowledge. PMID:28135430

  19. Evaluating Predictive Models of Software Quality

    NASA Astrophysics Data System (ADS)

    Ciaschini, V.; Canaparo, M.; Ronchieri, E.; Salomoni, D.

    2014-06-01

    Applications from High Energy Physics scientific community are constantly growing and implemented by a large number of developers. This implies a strong churn on the code and an associated risk of faults, which is unavoidable as long as the software undergoes active evolution. However, the necessities of production systems run counter to this. Stability and predictability are of paramount importance; in addition, a short turn-around time for the defect discovery-correction-deployment cycle is required. A way to reconcile these opposite foci is to use a software quality model to obtain an approximation of the risk before releasing a program to only deliver software with a risk lower than an agreed threshold. In this article we evaluated two quality predictive models to identify the operational risk and the quality of some software products. We applied these models to the development history of several EMI packages with intent to discover the risk factor of each product and compare it with its real history. We attempted to determine if the models reasonably maps reality for the applications under evaluation, and finally we concluded suggesting directions for further studies.

  20. A mixed methods approach to developing and evaluating oncology trainee education around minimization of adverse events and improved patient quality and safety.

    PubMed

    Janssen, Anna; Shaw, Tim; Bradbury, Lauren; Moujaber, Tania; Nørrelykke, Anne Mette; Zerillo, Jessica A; LaCasce, Ann; Co, John Patrick T; Robinson, Tracy; Starr, Alison; Harnett, Paul

    2016-03-12

    Adverse events are a significant quality and safety issue in the hospital setting due to their direct impact on patients. Additionally, such events are often handled by junior doctors due to their direct involvement with patients. As such, it is important for health care organizations to prioritize education and training for junior doctors on identifying adverse events and handling them when they occur. The Cancer Cup Challenge is an educational program focuses on quality improvement and adverse event awareness targeting for junior oncology doctors across three international sites. A mixed methodology was used to develop and evaluate the program. The Qstream spaced learning platform was used to disseminate information to participants, as it has been demonstrated to impact on both knowledge and behavior. Eight short case based scenarios with expert feedback were developed by a multidisciplinary advisory committee containing representatives from the international sites. At the conclusion of the course impact on participant knowledge was evaluated using analysis of the metrics collected by the Qstream platform. Additionally, an online survey and semi-structured interviews were used to evaluate engagement and perceived value by participants. A total of 35 junior doctors registered to undertake the Qstream program, with 31 (88.57 %) successfully completing it. Analysis of the Qstream metrics revealed 76.57 % of cases were answered correctly on first attempt. The post-program survey received 17 responses, with 76.47 % indicating cases for the course were interesting and 82.35 % feeling cases were relevant. Finally, 14 participants consented to participate in semi-structured interviews about the program, with feedback towards the course being generally very positive. Our study demonstrates that an online game is well accepted by junior doctors as a method to increase their quality improvement awareness. Developing effective and sustainable training for doctors is

  1. Evaluation of thermal effects on the beam quality of disk laser with unstable resonator

    NASA Astrophysics Data System (ADS)

    Shayganmanesh, Mahdi; Beirami, Reza

    2017-01-01

    In this paper thermal effects of the disk active medium and associated effects on the beam quality of laser are investigated. Using Collins integral and iterative method, transverse mode of an unstable resonator including a Yb:YAG active medium in disk geometry is calculated. After that the beam quality of the laser is calculated based on the generalized beam characterization method. Thermal lensing of the disk is calculated based on the OPD (Optical Path Difference) concept. Five factors influencing the OPD including temperature gradient, disk thermal expansion, photo-elastic effect, electronic lens and disk deformation are considered in our calculations. The calculations show that the effect of disk deformation factor on the quality of laser beam in the resonator is strong. However the total effect of all the thermal factors on the internal beam quality is fewer. Also it is shown that thermal effects degrade the output power, beam profile and beam quality of the output laser beam severely. As well the magnitude of each of affecting factors is evaluated distinctly.

  2. Evaluating a nursing care delivery model using a quality improvement design.

    PubMed

    Nardone, P L; Markie, J W; Tolle, S

    1995-10-01

    The goal to develop and implement a new model of nursing care delivery grew out of administrative and shared governance initiatives to improve the quality of nursing care. This evaluative study used both quantitative and qualitative methods. Seven principles related to quality were identified and became the driving force behind the changes. Aspects of these changes in care delivery were piloted on a neurological unit and included implementation of collaborative rounds, a modular structure, role changes, and work redesign. Frequency distribution, questionnaire, focus group, and financial data indicated that there had been improvement in the delivery of care in addition to financial benefits. A considerable amount of the data provided evidence that supported continuing the changes.

  3. An Innovative Method for Monitoring Food Quality and the Healthfulness of Consumers' Grocery Purchases.

    PubMed

    Tran, Le-Thuy T; Brewster, Philip J; Chidambaram, Valliammai; Hurdle, John F

    2017-05-05

    This study presents a method laying the groundwork for systematically monitoring food quality and the healthfulness of consumers' point-of-sale grocery purchases. The method automates the process of identifying United States Department of Agriculture (USDA) Food Patterns Equivalent Database (FPED) components of grocery food items. The input to the process is the compact abbreviated descriptions of food items that are similar to those appearing on the point-of-sale sales receipts of most food retailers. The FPED components of grocery food items are identified using Natural Language Processing techniques combined with a collection of food concept maps and relationships that are manually built using the USDA Food and Nutrient Database for Dietary Studies, the USDA National Nutrient Database for Standard Reference, the What We Eat In America food categories, and the hierarchical organization of food items used by many grocery stores. We have established the construct validity of the method using data from the National Health and Nutrition Examination Survey, but further evaluation of validity and reliability will require a large-scale reference standard with known grocery food quality measures. Here we evaluate the method's utility in identifying the FPED components of grocery food items available in a large sample of retail grocery sales data (~190 million transaction records).

  4. Evaluating Regional-Scale Air Quality Models

    EPA Science Inventory

    Numerical air quality models are being used to understand the complex interplay among emission loading meteorology, and atmospheric chemistry leading to the formation and accumulation of pollutants in the atmosphere. A model evaluation framework is presented here that considers ...

  5. Evaluating the State of Quality-Improvement Science through Evidence Synthesis: Insights from the Closing the Quality Gap Series

    PubMed Central

    McDonald, Kathryn M; Schultz, Ellen M; Chang, Christine

    2013-01-01

    Context: The Closing the Quality Gap series from the Agency for Healthcare Research and Quality summarizes evidence for eight high-priority health care topics: outcomes used in disability research, bundled payment programs, public reporting initiatives, health care disparities, palliative care, the patient-centered medical home, prevention of health care-associated infections, and medication adherence. Objective: To distill evidence from this series and provide insight into the “state of the science” of quality improvement (QI). Methods: We provided common guidance for topic development and qualitatively synthesized evidence from the series topic reports to identify cross-topic themes, challenges, and evidence gaps as related to QI practice and science. Results: Among topics that examined effectiveness of QI interventions, we found improvement in some outcomes but not others. Implementation context and potential harms from QI activities were not widely evaluated or reported, although market factors appeared important for incentive-based QI strategies. Patient-focused and systems-focused strategies were generally more effective than clinician-focused strategies, although the latter approach improved clinician adherence to infection prevention strategies. Audit and feedback appeared better for targeting professionals and organizations, but not patients. Topic reviewers observed heterogeneity in outcomes used for QI evaluations, weaknesses in study design, and incomplete reporting. Conclusions: Synthesizing evidence across topics provided insight into the state of the QI field for practitioners and researchers. To facilitate future evidence synthesis, consensus is needed around a smaller set of outcomes for use in QI evaluations and a framework and lexicon to describe QI interventions more broadly, in alignment with needs of decision makers responsible for improving quality. PMID:24079357

  6. DEVELOPMENT OF GUIDELINES FOR CALIBRATING, VALIDATING, AND EVALUATING HYDROLOGIC AND WATER QUALITY MODELS: ASABE ENGINEERING PRACTICE 621

    USDA-ARS?s Scientific Manuscript database

    Information to support application of hydrologic and water quality (H/WQ) models abounds, yet modelers commonly use arbitrary, ad hoc methods to conduct, document, and report model calibration, validation, and evaluation. Consistent methods are needed to improve model calibration, validation, and e...

  7. COMPUTERIZED NEEDS-ORIENTED QUALITY MEASUREMENT EVALUATION SYSTEM (CONQUEST)

    EPA Science Inventory

    CONQUEST is an easy-to-use quality improvement software tool that uses a common structure and language to help users identity, understand, compare, evaluate, and select among 1,200 clinical performance measures that can be used to assess and improve quality of care. CONQUEST's in...

  8. Multiple Criteria Evaluation of Quality and Optimisation of e-Learning System Components

    ERIC Educational Resources Information Center

    Kurilovas, Eugenijus; Dagiene, Valentina

    2010-01-01

    The main research object of the paper is investigation and proposal of the comprehensive Learning Object Repositories (LORs) quality evaluation tool suitable for their multiple criteria decision analysis, evaluation and optimisation. Both LORs "internal quality" and "quality in use" evaluation (decision making) criteria are analysed in the paper.…

  9. [Analgesic quality in a postoperative pain service: continuous assessment with the cumulative sum (cusum) method].

    PubMed

    Baptista Macaroff, W M; Castroman Espasandín, P

    2007-01-01

    The aim of this study was to assess the cumulative sum (cusum) method for evaluating the performance of our hospital's acute postoperative pain service. The period of analysis was 7 months. Analgesic failure was defined as a score of 3 points or more on a simple numerical scale. Acceptable failure (p0) was set at 20% of patients upon admission to the postanesthetic recovery unit and at 7% 24 hours after surgery. Unacceptable failure was set at double the p0 rate at each time (40% and 14%, respectively). The unit's patient records were used to generate a cusum graph for each evaluation. Nine hundred four records were included. The rate of failure was 31.6% upon admission to the unit and 12.1% at the 24-hour postoperative assessment. The curve rose rapidly to the value set for p0 at both evaluation times (n = 14 and n = 17, respectively), later leveled off, and began to fall after 721 and 521 cases, respectively. Our study shows the efficacy of the cusum method for monitoring a proposed quality standard. The graph also showed periods of suboptimal performance that would not have been evident from analyzing the data en block. Thus the cusum method would facilitate rapid detection of periods in which quality declines.

  10. Evaluating Quality of Students' Support Services in Open Distance Learning

    ERIC Educational Resources Information Center

    Nsamba, Asteria; Makoe, Mpine

    2017-01-01

    Evaluating the quality of students' support services in distance education institutions is vital because by nature Open Distance Learning (ODL) is a high-involvement service industry, with multiple student support service encounters. Most quality evaluation models tend to view quality from the institutional perspective. As a result, little is…

  11. [Development of methods and instruments for external quality assurance in inpatient parent-child rehabilitation and prevention].

    PubMed

    Neuderth, S; Lukasczik, M; Musekamp, G; Gerlich, C; Saupe-Heide, M; Löbmann, R; Vogel, H

    2013-02-01

    There so far is no standardized program for external quality assurance in inpatient parent-child prevention and rehabilitation in Germany. Therefore, instruments and methods of external quality assurance were developed and evaluated on behalf of the federal-level health insurance institutions. On the level of structure quality, a modular questionnaire for assessing structural features of rehabilitation/prevention centers, basic and allocation criteria as well as a checklist for visitations were developed. Structural data were collected in a nationwide survey of parent-child prevention and rehabilitation centers. Process and outcome quality data were collected in n=38 centers. Process quality was assessed using multiple methods (process-related structural features, case-related routine documentation, and incident-related patient questionnaires). Outcome quality was measured via patient questionnaires (n=1 799 patients). We used a multi-level modelling approach by adjusting relevant confounders on institutional and patient levels. The methods, instruments and analyzing procedures developed for measuring quality on the level of structure, processes and outcomes were adjusted in cooperation with all relevant stakeholders. Results are exemplarily presented for all quality assurance tools. For most of the risk-adjusted outcome parameters, we found no significant differences between institutions. For the first time, a comprehensive, standardized and generally applicable set of methods and instruments for routine use in comparative quality measurement of inpatient parent-child prevention and rehabilitation is available. However, it should be considered that the very heterogeneous field of family-oriented measures can not be covered entirely by an external quality assurance program. Therefore, methods and instruments have to be adapted continuously to the specifics of this area of health care and to new developments. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Using a fuzzy comprehensive evaluation method to determine product usability: A test case

    PubMed Central

    Zhou, Ronggang; Chan, Alan H. S.

    2016-01-01

    BACKGROUND: In order to take into account the inherent uncertainties during product usability evaluation, Zhou and Chan [1] proposed a comprehensive method of usability evaluation for products by combining the analytic hierarchy process (AHP) and fuzzy evaluation methods for synthesizing performance data and subjective response data. This method was designed to provide an integrated framework combining the inevitable vague judgments from the multiple stages of the product evaluation process. OBJECTIVE AND METHODS: In order to illustrate the effectiveness of the model, this study used a summative usability test case to assess the application and strength of the general fuzzy usability framework. To test the proposed fuzzy usability evaluation framework [1], a standard summative usability test was conducted to benchmark the overall usability of a specific network management software. Based on the test data, the fuzzy method was applied to incorporate both the usability scores and uncertainties involved in the multiple components of the evaluation. Then, with Monte Carlo simulation procedures, confidence intervals were used to compare the reliabilities among the fuzzy approach and two typical conventional methods combining metrics based on percentages. RESULTS AND CONCLUSIONS: This case study showed that the fuzzy evaluation technique can be applied successfully for combining summative usability testing data to achieve an overall usability quality for the network software evaluated. Greater differences of confidence interval widths between the method of averaging equally percentage and weighted evaluation method, including the method of weighted percentage averages, verified the strength of the fuzzy method. PMID:28035942

  13. Monitoring and evaluating the quality consistency of Compound Bismuth Aluminate tablets by a simple quantified ratio fingerprint method combined with simultaneous determination of five compounds and correlated with antioxidant activities.

    PubMed

    Liu, Yingchun; Liu, Zhongbo; Sun, Guoxiang; Wang, Yan; Ling, Junhong; Gao, Jiayue; Huang, Jiahao

    2015-01-01

    A combination method of multi-wavelength fingerprinting and multi-component quantification by high performance liquid chromatography (HPLC) coupled with diode array detector (DAD) was developed and validated to monitor and evaluate the quality consistency of herbal medicines (HM) in the classical preparation Compound Bismuth Aluminate tablets (CBAT). The validation results demonstrated that our method met the requirements of fingerprint analysis and quantification analysis with suitable linearity, precision, accuracy, limits of detection (LOD) and limits of quantification (LOQ). In the fingerprint assessments, rather than using conventional qualitative "Similarity" as a criterion, the simple quantified ratio fingerprint method (SQRFM) was recommended, which has an important quantified fingerprint advantage over the "Similarity" approach. SQRFM qualitatively and quantitatively offers the scientific criteria for traditional Chinese medicines (TCM)/HM quality pyramid and warning gate in terms of three parameters. In order to combine the comprehensive characterization of multi-wavelength fingerprints, an integrated fingerprint assessment strategy based on information entropy was set up involving a super-information characteristic digitized parameter of fingerprints, which reveals the total entropy value and absolute information amount about the fingerprints and, thus, offers an excellent method for fingerprint integration. The correlation results between quantified fingerprints and quantitative determination of 5 marker compounds, including glycyrrhizic acid (GLY), liquiritin (LQ), isoliquiritigenin (ILG), isoliquiritin (ILQ) and isoliquiritin apioside (ILA), indicated that multi-component quantification could be replaced by quantified fingerprints. The Fenton reaction was employed to determine the antioxidant activities of CBAT samples in vitro, and they were correlated with HPLC fingerprint components using the partial least squares regression (PLSR) method. In

  14. Effects of different drying methods on the product quality and volatile compounds of whole shiitake mushrooms.

    PubMed

    Tian, Yuting; Zhao, Yingting; Huang, Jijun; Zeng, Hongliang; Zheng, Baodong

    2016-04-15

    Various drying methods play important roles in the preservation of foods. However, how the different drying methods affect the quality of some foods is not clear. This paper evaluates the effects of hot air, vacuum, microwave, and microwave vacuum drying techniques on important qualities and volatile compounds of whole shiitake (Lentinus edodes) mushrooms. These four drying methods resulted in a significantly (p<0.05) increase in the content of total free amino acids and the relative content of sulfur compounds of dried products. Microwave vacuum drying helped to maintain larger amounts of taste-active amino acids, and improved nutrient retention and color attributes. Furthermore, the uniform honeycomb network created by microwave vacuum drying along with a less collapsed structure of dried samples can be used to explain the observed high rehydration ratio. Therefore, microwave vacuum drying should be a potential method for obtaining high-quality dried mushrooms. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Content-based quality evaluation of color images: overview and proposals

    NASA Astrophysics Data System (ADS)

    Tremeau, Alain; Richard, Noel; Colantoni, Philippe; Fernandez-Maloigne, Christine

    2003-12-01

    The automatic prediction of perceived quality from image data in general, and the assessment of particular image characteristics or attributes that may need improvement in particular, becomes an increasingly important part of intelligent imaging systems. The purpose of this paper is to propose to the color imaging community in general to develop a software package available on internet to help the user to select among all these approaches which is better appropriated to a given application. The ultimate goal of this project is to propose, next to implement, an open and unified color imaging system to set up a favourable context for the evaluation and analysis of color imaging processes. Many different methods for measuring the performance of a process have been proposed by different researchers. In this paper, we will discuss the advantages and shortcomings of most of main analysis criteria and performance measures currently used. The aim is not to establish a harsh competition between algorithms or processes, but rather to test and compare the efficiency of methodologies firstly to highlight strengths and weaknesses of a given algorithm or methodology on a given image type and secondly to have these results publicly available. This paper is focused on two important unsolved problems. Why it is so difficult to select a color space which gives better results than another one? Why it is so difficult to select an image quality metric which gives better results than another one, with respect to the judgment of the Human Visual System? Several methods used either in color imaging or in image quality will be thus discussed. Proposals for content-based image measures and means of developing a standard test suite for will be then presented. The above reference advocates for an evaluation protocol based on an automated procedure. This is the ultimate goal of our proposal.

  16. A new method for water quality assessment: by harmony degree equation.

    PubMed

    Zuo, Qiting; Han, Chunhui; Liu, Jing; Ma, Junxia

    2018-02-22

    Water quality assessment is an important basic work in the development, utilization, management, and protection of water resources, and also a prerequisite for water safety. In this paper, the harmony degree equation (HDE) was introduced into the research of water quality assessment, and a new method for water quality assessment was proposed according to the HDE: by harmony degree equation (WQA-HDE). First of all, the calculation steps and ideas of this method were described in detail, and then, this method with some other important methods of water quality assessment (single factor assessment method, mean-type comprehensive index assessment method, and multi-level gray correlation assessment method) were used to assess the water quality of the Shaying River (the largest tributary of the Huaihe in China). For this purpose, 2 years (2013-2014) dataset of nine water quality variables covering seven monitoring sites, and approximately 189 observations were used to compare and analyze the characteristics and advantages of the new method. The results showed that the calculation steps of WQA-HDE are similar to the comprehensive assessment method, and WQA-HDE is more operational comparing with the results of other water quality assessment methods. In addition, this new method shows good flexibility by setting the judgment criteria value HD 0 of water quality; when HD 0  = 0.8, the results are closer to reality, and more realistic and reliable. Particularly, when HD 0  = 1, the results of WQA-HDE are consistent with the single factor assessment method, both methods are subject to the most stringent "one vote veto" judgment condition. So, WQA-HDE is a composite method that combines the single factor assessment and comprehensive assessment. This research not only broadens the research field of theoretical method system of harmony theory but also promotes the unity of water quality assessment method and can be used for reference in other comprehensive assessment.

  17. Solvent and extraction methods effects on the quality of eel (Anguilla bicolor) oil

    NASA Astrophysics Data System (ADS)

    Sasongko, H.; Efendi, N. R.; Budihardjo, A.; Farida, Y.; Amartiwi, T.; Rahmawati, A. A.; Wicaksono, A.; Sugiyarto

    2017-01-01

    Eel (Anguilla bicolor) is a general fish consumption in many countries, especially Japan, China, Germany, and France. Besides its vitamin rich, eel oil is also known to contain fatty acids that are necessary for pharmaceutical purposes and as food a supplement. This research was aimed to evaluate the quality of eel oil by different solvent and extraction methods. In this study, fresh eels were extracted using maceration and reflux methods.Chloroform was used as the solvent in the maceration while water used in the reflux method. The oil quality was examined based on the Official Methods of Analysis of the Association of Official Analytical Chemist (AOAC).The result showed that the yield of eel oil using maceration method was 5.44% ± 0.64 with a specific gravity of 0.915 g/mL, while reflux method obtained the yield of 5.33 % ± 0.84 and specific gravity of 0.8575 g/mL. The physicochemical parameters of oil quality used in this study were acid, peroxide, saponification, and iodine value. The maceration method obtained the acid value of 17.389 mgKOH/g, the peroxide value of 7.021meqO2/kg, the saponification value of 111.16mgKOH/g, and the iodine value of 65.14 WIJS. While the reflux method produced the acid value of 9.116 mgKOH/g, the peroxide value of 6.088 meqO2/kg, the saponification value of 70 mgKOH/g, and the iodine value of 87.74 WIJS.

  18. Quality Evaluation Scores are no more Reliable than Gestalt in Evaluating the Quality of Emergency Medicine Blogs: A METRIQ Study.

    PubMed

    Thoma, Brent; Sebok-Syer, Stefanie S; Colmers-Gray, Isabelle; Sherbino, Jonathan; Ankel, Felix; Trueger, N Seth; Grock, Andrew; Siemens, Marshall; Paddock, Michael; Purdy, Eve; Kenneth Milne, William; Chan, Teresa M

    2018-01-30

    Construct: We investigated the quality of emergency medicine (EM) blogs as educational resources. Online medical education resources such as blogs are increasingly used by EM trainees and clinicians. However, quality evaluations of these resources using gestalt are unreliable. We investigated the reliability of two previously derived quality evaluation instruments for blogs. Sixty English-language EM websites that published clinically oriented blog posts between January 1 and February 24, 2016, were identified. A random number generator selected 10 websites, and the 2 most recent clinically oriented blog posts from each site were evaluated using gestalt, the Academic Life in Emergency Medicine (ALiEM) Approved Instructional Resources (AIR) score, and the Medical Education Translational Resources: Impact and Quality (METRIQ-8) score, by a sample of medical students, EM residents, and EM attendings. Each rater evaluated all 20 blog posts with gestalt and 15 of the 20 blog posts with the ALiEM AIR and METRIQ-8 scores. Pearson's correlations were calculated between the average scores for each metric. Single-measure intraclass correlation coefficients (ICCs) evaluated the reliability of each instrument. Our study included 121 medical students, 88 EM residents, and 100 EM attendings who completed ratings. The average gestalt rating of each blog post correlated strongly with the average scores for ALiEM AIR (r = .94) and METRIQ-8 (r = .91). Single-measure ICCs were fair for gestalt (0.37, IQR 0.25-0.56), ALiEM AIR (0.41, IQR 0.29-0.60) and METRIQ-8 (0.40, IQR 0.28-0.59). The average scores of each blog post correlated strongly with gestalt ratings. However, neither ALiEM AIR nor METRIQ-8 showed higher reliability than gestalt. Improved reliability may be possible through rater training and instrument refinement.

  19. A potential non-invasive approach to evaluating blastocyst quality using biodynamic imaging

    NASA Astrophysics Data System (ADS)

    Li, Zhe; Ehmke, Natalie; Machaty, Zoltan; Nolte, David

    2018-02-01

    Biodynamic imaging (BDI) is capable of capturing the intracellular dynamics of blastocysts within a relatively short time. Spectroscopic signatures of embryos in the 0.01 Hz - 1 Hz range display responses to external factors before morphology changes take place. Viability evaluation is consistent with results from other non-invasive methods. Biodynamic imaging is a potential tool for selecting high quality embryos in clinical IVF practices.

  20. Application of Kolomogorov-Zurbenko Filter and the decoupled direct 3D method for the dynamic evaluation of a regional air quality model

    EPA Science Inventory

    Regional air quality models are being used in a policy-setting to estimate the response of air pollutant concentrations to changes in emissions and meteorology. Dynamic evaluation entails examination of a retrospective case(s) to assess whether an air quality model has properly p...

  1. Applications of emerging imaging techniques for meat quality and safety detection and evaluation: A review.

    PubMed

    Xiong, Zhenjie; Sun, Da-Wen; Pu, Hongbin; Gao, Wenhong; Dai, Qiong

    2017-03-04

    With improvement in people's living standards, many people nowadays pay more attention to quality and safety of meat. However, traditional methods for meat quality and safety detection and evaluation, such as manual inspection, mechanical methods, and chemical methods, are tedious, time-consuming, and destructive, which cannot meet the requirements of modern meat industry. Therefore, seeking out rapid, non-destructive, and accurate inspection techniques is important for the meat industry. In recent years, a number of novel and noninvasive imaging techniques, such as optical imaging, ultrasound imaging, tomographic imaging, thermal imaging, and odor imaging, have emerged and shown great potential in quality and safety assessment. In this paper, a detailed overview of advanced applications of these emerging imaging techniques for quality and safety assessment of different types of meat (pork, beef, lamb, chicken, and fish) is presented. In addition, advantages and disadvantages of each imaging technique are also summarized. Finally, future trends for these emerging imaging techniques are discussed, including integration of multiple imaging techniques, cost reduction, and developing powerful image-processing algorithms.

  2. A 1064 nm dispersive Raman spectral imaging system for food safety and quality evaluation

    USDA-ARS?s Scientific Manuscript database

    Raman spectral imaging is an effective method to analyze and evaluate chemical composition and structure of a sample, and has many applications for food safety and quality research. This study developed a 1064 nm Raman spectral imaging system for surface and subsurface analysis of food samples. A 10...

  3. Evaluation of the methods for enumerating coliform bacteria from water samples using precise reference standards.

    PubMed

    Wohlsen, T; Bates, J; Vesey, G; Robinson, W A; Katouli, M

    2006-04-01

    To use BioBall cultures as a precise reference standard to evaluate methods for enumeration of Escherichia coli and other coliform bacteria in water samples. Eight methods were evaluated including membrane filtration, standard plate count (pour and spread plate methods), defined substrate technology methods (Colilert and Colisure), the most probable number method and the Petrifilm disposable plate method. Escherichia coli and Enterobacter aerogenes BioBall cultures containing 30 organisms each were used. All tests were performed using 10 replicates. The mean recovery of both bacteria varied with the different methods employed. The best and most consistent results were obtained with Petrifilm and the pour plate method. Other methods either yielded a low recovery or showed significantly high variability between replicates. The BioBall is a very suitable quality control tool for evaluating the efficiency of methods for bacterial enumeration in water samples.

  4. Evaluating the quality of perinatal anxiety information available online.

    PubMed

    Kirby, Paige L; Reynolds, Kristin A; Walker, John R; Furer, Patricia; Pryor, Teaghan A M

    2018-06-22

    The Internet is an easily accessible source of information for women experiencing anxiety in pregnancy and/or postpartum to use when seeking health information. However, the Internet has several drawbacks, including inaccurate content that may be perceived as being accurate, non-biased, and evidence-based. Prior research indicates that anxiety and postpartum mental health websites have poor quality in terms of describing treatment options. There is a lack of research and knowledge in the area of perinatal anxiety, and an absence of research evaluating perinatal anxiety websites. The purpose of this study was to evaluate the quality of information regarding perinatal anxiety available on the Internet. Websites concerning perinatal anxiety were selected using the Google search engine. Each website was evaluated based on quality of health information, website usability, and readability. The 20 websites included in this study had low to moderate quality scores based on the DISCERN tool. There were no associations found between website order and website quality, or between website readability and website quality. Many websites had high PEMAT scores for the understandability section, which included content, style, and layout of information; however, most did not use visual aids to enhance comprehension. Most websites had low actionability scores, suggesting that information may not be useful in describing what actions may be taken to manage perinatal anxiety. This study highlights the need for high-quality websites concerning perinatal anxiety that are easy to navigate and provide the public with evidence-based information.

  5. Water quality evaluation of Al-Gharraf river by two water quality indices

    NASA Astrophysics Data System (ADS)

    Ewaid, Salam Hussein

    2017-11-01

    Water quality of Al-Gharraf river, the largest branch of Tigris River south of Iraq, was evaluated by the National Sanitation Foundation Water Quality Index (NFS WQI) and the Heavy Metal Pollution Index (HPI) depending on 13 physical, chemical, and biological parameters of water quality measured monthly at ten stations on the river during 2015. The NSF-WQI range obtained for the sampling sites was 61-70 indicating a medium water quality. The HPI value was 98.6 slightly below the critical value for drinking water of 100, and the water quality in the upstream stations is better than downstream due to decrease in water and the accumulation of contaminants along the river. This study explains the significance of applying the water quality indices that show the aggregate impact of ecological factors in charge of water pollution of surface water and which permits translation of the monitoring data to assist the decision makers.

  6. Regionalized PM2.5 Community Multiscale Air Quality model performance evaluation across a continuous spatiotemporal domain.

    PubMed

    Reyes, Jeanette M; Xu, Yadong; Vizuete, William; Serre, Marc L

    2017-01-01

    The regulatory Community Multiscale Air Quality (CMAQ) model is a means to understanding the sources, concentrations and regulatory attainment of air pollutants within a model's domain. Substantial resources are allocated to the evaluation of model performance. The Regionalized Air quality Model Performance (RAMP) method introduced here explores novel ways of visualizing and evaluating CMAQ model performance and errors for daily Particulate Matter ≤ 2.5 micrometers (PM2.5) concentrations across the continental United States. The RAMP method performs a non-homogenous, non-linear, non-homoscedastic model performance evaluation at each CMAQ grid. This work demonstrates that CMAQ model performance, for a well-documented 2001 regulatory episode, is non-homogeneous across space/time. The RAMP correction of systematic errors outperforms other model evaluation methods as demonstrated by a 22.1% reduction in Mean Square Error compared to a constant domain wide correction. The RAMP method is able to accurately reproduce simulated performance with a correlation of r = 76.1%. Most of the error coming from CMAQ is random error with only a minority of error being systematic. Areas of high systematic error are collocated with areas of high random error, implying both error types originate from similar sources. Therefore, addressing underlying causes of systematic error will have the added benefit of also addressing underlying causes of random error.

  7. Development of quality assurance methods for epoxy graphite prepreg

    NASA Technical Reports Server (NTRS)

    Chen, J. S.; Hunter, A. B.

    1982-01-01

    Quality assurance methods for graphite epoxy/prepregs were developed. Liquid chromatography, differential scanning calorimetry, and gel permeation chromatography were investigated. These methods were applied to a second prepreg system. The resin matrix formulation was correlated with mechanical properties. Dynamic mechanical analysis and fracture toughness methods were investigated. The chromatography and calorimetry techniques were all successfully developed as quality assurance methods for graphite epoxy prepregs. The liquid chromatography method was the most sensitive to changes in resin formulation. The were also successfully applied to the second prepreg system.

  8. Fingerprint analysis and quality consistency evaluation of flavonoid compounds for fermented Guava leaf by combining high-performance liquid chromatography time-of-flight electrospray ionization mass spectrometry and chemometric methods.

    PubMed

    Wang, Lu; Tian, Xiaofei; Wei, Wenhao; Chen, Gong; Wu, Zhenqiang

    2016-10-01

    Guava leaves are used in traditional herbal teas as antidiabetic therapies. Flavonoids are the main active of Guava leaves and have many physiological functions. However, the flavonoid compositions and activities of Guava leaves could change due to microbial fermentation. A high-performance liquid chromatography time-of-flight electrospray ionization mass spectrometry method was applied to identify the varieties of the flavonoids in Guava leaves before and after fermentation. High-performance liquid chromatography, hierarchical cluster analysis and principal component analysis were used to quantitatively determine the changes in flavonoid compositions and evaluate the consistency and quality of Guava leaves. Monascus anka Saccharomyces cerevisiae fermented Guava leaves contained 2.32- and 4.06-fold more total flavonoids and quercetin, respectively, than natural Guava leaves. The flavonoid compounds of the natural Guava leaves had similarities ranging from 0.837 to 0.927. The flavonoid compounds from the Monascus anka S. cerevisiae fermented Guava leaves had similarities higher than 0.993. This indicated that the quality consistency of the fermented Guava leaves was better than that of the natural Guava leaves. High-performance liquid chromatography fingerprinting and chemometric analysis are promising methods for evaluating the degree of fermentation of Guava leaves based on quality consistency, which could be used in assessing flavonoid compounds for the production of fermented Guava leaves. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Global chemical profiling based quality evaluation approach of rhubarb using ultra performance liquid chromatography with tandem quadrupole time-of-flight mass spectrometry.

    PubMed

    Zhang, Li; Liu, Haiyu; Qin, Lingling; Zhang, Zhixin; Wang, Qing; Zhang, Qingqing; Lu, Zhiwei; Wei, Shengli; Gao, Xiaoyan; Tu, Pengfei

    2015-02-01

    A global chemical profiling based quality evaluation approach using ultra performance liquid chromatography with tandem quadrupole time-of-flight mass spectrometry was developed for the quality evaluation of three rhubarb species, including Rheum palmatum L., Rheum tanguticum Maxim. ex Balf., and Rheum officinale Baill. Considering that comprehensive detection of chemical components is crucial for the global profile, a systemic column performance evaluation method was developed. Based on this, a Cortecs column was used to acquire the chemical profile, and Chempattern software was employed to conduct similarity evaluation and hierarchical cluster analysis. The results showed R. tanguticum could be differentiated from R. palmatum and R. officinale at the similarity value 0.65, but R. palmatum and R. officinale could not be distinguished effectively. Therefore, a common pattern based on three rhubarb species was developed to conduct the quality evaluation, and the similarity value 0.50 was set as an appropriate threshold to control the quality of rhubarb. A total of 88 common peaks were identified by their accurate mass and fragmentation, and partially verified by reference standards. Through the verification, the newly developed method could be successfully used for evaluating the holistic quality of rhubarb. It would provide a reference for the quality control of other herbal medicines. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Managing Air Quality - Ongoing Evaluation of Progress

    EPA Pesticide Factsheets

    Describes the importance of evaluating if air quality programs are achieving the desired results to inform environmental program managers, regulated industry and the public, and provides EPA examples.

  11. An Exploration of the Examination Script Features that Most Influence Expert Judgements in Three Methods of Evaluating Script Quality

    ERIC Educational Resources Information Center

    Suto, Irenka; Novakovic, Nadezda

    2012-01-01

    Some methods of determining grade boundaries within examinations, such as awarding, paired comparisons, and rank ordering, entail expert judgements of script quality. We aimed to identify the features of examinees' scripts that most influence judgements in the three methods. For contrasting examinations in biology and English, a Latin square…

  12. Efficient clinical evaluation of guideline quality: development and testing of a new tool

    PubMed Central

    2014-01-01

    Background Evaluating the methodological quality of clinical practice guidelines is essential before deciding which ones which could best inform policy or practice. One current method of evaluating clinical guideline quality is the research-focused AGREE II instrument. This uses 23 questions scored 1–7, arranged in six domains, which requires at least two independent testers, and uses a formulaic weighted domain scoring system. Following feedback from time-poor clinicians, policy-makers and managers that this instrument did not suit clinical need, we developed and tested a simpler, shorter, binary scored instrument (the iCAHE Guideline Quality Checklist) designed for single users. Methods Content and construct validity, inter-tester reliability and clinical utility were tested by comparing the new iCAHE Guideline Quality Checklist with the AGREE II instrument. Firstly the questions and domains in both instruments were compared. Six randomly-selected guidelines on a similar theme were then assessed by three independent testers with different experience in guideline quality assessment, using both instruments. Per guideline, weighted domain and total AGREE II scores were calculated, using the scoring rubric for three testers. Total iCAHE scores were calculated per guideline, per tester. The linear relationship between iCAHE and AGREE II scores was assessed using Pearson r correlation coefficients. Score differences between testers were assessed for the iCAHE Guideline Quality Checklist. Results There were congruent questions in each instrument in four domains (Scope & Purpose, Stakeholder involvement, Underlying evidence/Rigour, Clarity). The iCAHE and AGREE II scores were moderate to strongly correlated for the six guidelines. There was generally good agreement between testers for iCAHE scores, irrespective of their experience. The iCAHE instrument was preferred by all testers, and took significantly less time to administer than the AGREE II instrument. However

  13. Evaluation of the performance of a micromethod for measuring urinary iodine by using six sigma quality metrics.

    PubMed

    Hussain, Husniza; Khalid, Norhayati Mustafa; Selamat, Rusidah; Wan Nazaimoon, Wan Mohamud

    2013-09-01

    The urinary iodine micromethod (UIMM) is a modification of the conventional method and its performance needs evaluation. UIMM performance was evaluated using the method validation and 2008 Iodine Deficiency Disorders survey data obtained from four urinary iodine (UI) laboratories. Method acceptability tests and Sigma quality metrics were determined using total allowable errors (TEas) set by two external quality assurance (EQA) providers. UIMM obeyed various method acceptability test criteria with some discrepancies at low concentrations. Method validation data calculated against the UI Quality Program (TUIQP) TEas showed that the Sigma metrics were at 2.75, 1.80, and 3.80 for 51±15.50 µg/L, 108±32.40 µg/L, and 149±38.60 µg/L UI, respectively. External quality control (EQC) data showed that the performance of the laboratories was within Sigma metrics of 0.85-1.12, 1.57-4.36, and 1.46-4.98 at 46.91±7.05 µg/L, 135.14±13.53 µg/L, and 238.58±17.90 µg/L, respectively. No laboratory showed a calculated total error (TEcalc)Quality of UI Procedures (EQUIP) TEas, the performance of all laboratories was≤2.49 Sigma metrics at all concentrations. Only one laboratory had TEcalc

  14. Accurate evaluation and analysis of functional genomics data and methods

    PubMed Central

    Greene, Casey S.; Troyanskaya, Olga G.

    2016-01-01

    The development of technology capable of inexpensively performing large-scale measurements of biological systems has generated a wealth of data. Integrative analysis of these data holds the promise of uncovering gene function, regulation, and, in the longer run, understanding complex disease. However, their analysis has proved very challenging, as it is difficult to quickly and effectively assess the relevance and accuracy of these data for individual biological questions. Here, we identify biases that present challenges for the assessment of functional genomics data and methods. We then discuss evaluation methods that, taken together, begin to address these issues. We also argue that the funding of systematic data-driven experiments and of high-quality curation efforts will further improve evaluation metrics so that they more-accurately assess functional genomics data and methods. Such metrics will allow researchers in the field of functional genomics to continue to answer important biological questions in a data-driven manner. PMID:22268703

  15. Evaluation of mobile phone addiction level and sleep quality in university students

    PubMed Central

    Sahin, Sevil; Ozdemir, Kevser; Unsal, Alaattin; Temiz, Nazen

    2013-01-01

    Objective: To determine the mobile phone addiction level in university students, to examine several associated factors and to evaluate the relation between the addiction level and sleep quality. Methods: The study is a cross-sectional research conducted on the students of the Sakarya University between 01 November 2012 and 01 February 2013. The study group included 576 students. The Problematic Mobile Phone Use Scale was used for evaluating the mobile phone addiction level and the Pittsburgh Sleep Quality Index for assessing the sleep quality. Mann-Whitney U test, Kruskal-Wallis test and Spearman’s Correlation Analysis were used for analyzing the data. Results: The study group consisted of 296 (51.4%) females and 208 (48.6%) males. The mean age was 20.83 ± 1.90 years (min:17, max:28). The addiction level was determined to be higher in the second-year students, those with poor family income, those with type A personality, those whose age for first mobile phone is 13 and below and those whose duration of daily mobile phone use is above 5 hours (p < 0.05 for each). The sleep quality worsens with increasing mobile phone addiction level (p < 0.05). Conclusion: The sleep quality worsens with increasing addiction level. It was concluded that referring the students with suspected addiction to advanced healthcare facilities, performing occasional scans for early diagnosis and informing the students about controlled mobile phone use would be useful. PMID:24353658

  16. Evaluating the beam quality of double-cladding fiber lasers in applications.

    PubMed

    Yan, Ping; Wang, Xuejiao; Gong, Mali; Xiao, Qirong

    2016-08-10

    We put forward a new βFL factor, which is used exclusively in fiber lasers and is suitable to assess beam quality and choose the LP01 mode as the new suitable ideal beam. We present a new simple measurement method and verify the reasonability of the βFL factor in experiment in a 20/400 μm fiber laser. Furthermore, we use the βFL factor to evaluate the beam quality of a 3-kW-level fiber laser. It can be concluded that βFL is a key factor not only for assessing the performance of the high-power fiber laser that is our main focus, but also for the simple measurement.

  17. Evaluating the utility of two gestural discomfort evaluation methods

    PubMed Central

    Son, Minseok; Jung, Jaemoon; Park, Woojin

    2017-01-01

    Evaluating physical discomfort of designed gestures is important for creating safe and usable gesture-based interaction systems; yet, gestural discomfort evaluation has not been extensively studied in HCI, and few evaluation methods seem currently available whose utility has been experimentally confirmed. To address this, this study empirically demonstrated the utility of the subjective rating method after a small number of gesture repetitions (a maximum of four repetitions) in evaluating designed gestures in terms of physical discomfort resulting from prolonged, repetitive gesture use. The subjective rating method has been widely used in previous gesture studies but without empirical evidence on its utility. This study also proposed a gesture discomfort evaluation method based on an existing ergonomics posture evaluation tool (Rapid Upper Limb Assessment) and demonstrated its utility in evaluating designed gestures in terms of physical discomfort resulting from prolonged, repetitive gesture use. Rapid Upper Limb Assessment is an ergonomics postural analysis tool that quantifies the work-related musculoskeletal disorders risks for manual tasks, and has been hypothesized to be capable of correctly determining discomfort resulting from prolonged, repetitive gesture use. The two methods were evaluated through comparisons against a baseline method involving discomfort rating after actual prolonged, repetitive gesture use. Correlation analyses indicated that both methods were in good agreement with the baseline. The methods proposed in this study seem useful for predicting discomfort resulting from prolonged, repetitive gesture use, and are expected to help interaction designers create safe and usable gesture-based interaction systems. PMID:28423016

  18. A method to improve the nutritional quality of foods and beverages based on dietary recommendations.

    PubMed

    Nijman, C A J; Zijp, I M; Sierksma, A; Roodenburg, A J C; Leenen, R; van den Kerkhoff, C; Weststrate, J A; Meijer, G W

    2007-04-01

    The increasing consumer interest in health prompted Unilever to develop a globally applicable method (Nutrition Score) to evaluate and improve the nutritional composition of its foods and beverages portfolio. Based on (inter)national dietary recommendations, generic benchmarks were developed to evaluate foods and beverages on their content of trans fatty acids, saturated fatty acids, sodium and sugars. High intakes of these key nutrients are associated with undesirable health effects. In principle, the developed generic benchmarks can be applied globally for any food and beverage product. Product category-specific benchmarks were developed when it was not feasible to meet generic benchmarks because of technological and/or taste factors. The whole Unilever global foods and beverages portfolio has been evaluated and actions have been taken to improve the nutritional quality. The advantages of this method over other initiatives to assess the nutritional quality of foods are that it is based on the latest nutritional scientific insights and its global applicability. The Nutrition Score is the first simple, transparent and straightforward method that can be applied globally and across all food and beverage categories to evaluate the nutritional composition. It can help food manufacturers to improve the nutritional value of their products. In addition, the Nutrition Score can be a starting point for a powerful health indicator front-of-pack. This can have a significant positive impact on public health, especially when implemented by all food manufacturers.

  19. A Projection Quality-Driven Tube Current Modulation Method in Cone-Beam CT for IGRT: Proof of Concept.

    PubMed

    Men, Kuo; Dai, Jianrong

    2017-12-01

    To develop a projection quality-driven tube current modulation method in cone-beam computed tomography for image-guided radiotherapy based on the prior attenuation information obtained by the planning computed tomography and then evaluate its effect on a reduction in the imaging dose. The QCKV-1 phantom with different thicknesses (0-400 mm) of solid water upon it was used to simulate different attenuation (μ). Projections were acquired with a series of tube current-exposure time product (mAs) settings, and a 2-dimensional contrast to noise ratio was analyzed for each projection to create a lookup table of mAs versus 2-dimensional contrast to noise ratio, μ. Before a patient underwent computed tomography, the maximum attenuation [Formula: see text] within the 95% range of each projection angle (θ) was estimated according to the planning computed tomography images. Then, a desired 2-dimensional contrast to noise ratio value was selected, and the mAs setting at θ was calculated with the lookup table of mAs versus 2-dimensional contrast to noise ratio,[Formula: see text]. Three-dimensional cone-beam computed tomography images were reconstructed using the projections acquired with the selected mAs. The imaging dose was evaluated with a polymethyl methacrylate dosimetry phantom in terms of volume computed tomography dose index. Image quality was analyzed using a Catphan 503 phantom with an oval body annulus and a pelvis phantom. For the Catphan 503 phantom, the cone-beam computed tomography image obtained by the projection quality-driven tube current modulation method had a similar quality to that of conventional cone-beam computed tomography . However, the proposed method could reduce the imaging dose by 16% to 33% to achieve an equivalent contrast to noise ratio value. For the pelvis phantom, the structural similarity index was 0.992 with a dose reduction of 39.7% for the projection quality-driven tube current modulation method. The proposed method could reduce the

  20. Implementation and evaluation of a multisite drug usage evaluation program across Australian hospitals - a quality improvement initiative

    PubMed Central

    2011-01-01

    Background With the use of medicines being a broad and extensive part of health management, mechanisms to ensure quality use of medicines are essential. Drug usage evaluation (DUE) is an evidence-based quality improvement methodology, designed to improve the quality, safety and cost-effectiveness of drug use. The purpose of this paper is to describe a national DUE methodology used to improve health care delivery across the continuum through multi-faceted intervention involving audit and feedback, academic detailing and system change, and a qualitative assessment of the methodology, as illustrated by the Acute Postoperative Pain Management (APOP) project. Methods An established methodology, consisting of a baseline audit of inpatient medical records, structured patient interviews and general practitioner surveys, followed by an educational intervention and follow-up audit, is used. Australian hospitals, including private, public, metropolitan and regional, are invited to participate on a voluntary basis. De-identified data collected by hospitals are collated and evaluated nationally to provide descriptive comparative analyses. Hospitals benchmark their practices against state and national results to facilitate change. The educational intervention consists of academic detailing, group education, audit and feedback, point-of-prescribing prompts and system changes. A repeat data collection is undertaken to assess changes in practice. An online qualitative survey was undertaken to evaluate the APOP program. Qualitative assessment of hospitals' perceptions of the effectiveness of the overall DUE methodology and changes in procedure/prescribing/policy/clinical practice which resulted from participation were elicited. Results 62 hospitals participated in the APOP project. Among 23 respondents to the evaluation survey, 18 (78%) reported improvements in the documentation of pain scores at their hospital. 15 (65%) strongly agreed or agreed that participation in APOP directly

  1. Evaluating the Impact of Parent-Reported Medical Home Status on Children's Health Care Utilization, Expenditures, and Quality: A Difference-in-Differences Analysis with Causal Inference Methods.

    PubMed

    Han, Bing; Yu, Hao; Friedberg, Mark W

    2017-04-01

    To evaluate the effects of the parent-reported medical home status on health care utilization, expenditures, and quality for children. Medical Expenditure Panel Survey (MEPS) during 2004-2012, including a total of 9,153 children who were followed up for 2 years in the survey. We took a causal difference-in-differences approach using inverse probability weighting and doubly robust estimators to study how changes in medical home status over a 2-year period affected children's health care outcomes. Our analysis adjusted for children's sociodemographic, health, and insurance statuses. We conducted sensitivity analyses using alternative statistical methods, different approaches to outliers and missing data, and accounting for possible common-method biases. Compared with children whose parents reported having medical homes in both years 1 and 2, those who had medical homes in year 1 but lost them in year 2 had significantly lower parent-reported ratings of health care quality and higher utilization of emergency care. Compared with children whose parents reported having no medical homes in both years, those who did not have medical homes in year 1 but gained them in year 2 had significantly higher ratings of health care quality, but no significant differences in health care expenditures and utilization. Having a medical home may help improve health care quality for children; losing a medical home may lead to higher utilization of emergency care. © Health Research and Educational Trust.

  2. Reflections on Post-Evaluation of Baccalaureate Programs: Revisiting Education Quality

    ERIC Educational Resources Information Center

    Jianrong, Sun

    2009-01-01

    This paper discusses the distinction between two types of educational quality: quality at the institutional level and quality at the student learning level. The key element for continuous institutional improvement after completion of the evaluation of institutional teaching should be on redefining quality in student learning and developing a…

  3. Design of a practical model-observer-based image quality assessment method for CT imaging systems

    NASA Astrophysics Data System (ADS)

    Tseng, Hsin-Wu; Fan, Jiahua; Cao, Guangzhi; Kupinski, Matthew A.; Sainath, Paavana

    2014-03-01

    The channelized Hotelling observer (CHO) is a powerful method for quantitative image quality evaluations of CT systems and their image reconstruction algorithms. It has recently been used to validate the dose reduction capability of iterative image-reconstruction algorithms implemented on CT imaging systems. The use of the CHO for routine and frequent system evaluations is desirable both for quality assurance evaluations as well as further system optimizations. The use of channels substantially reduces the amount of data required to achieve accurate estimates of observer performance. However, the number of scans required is still large even with the use of channels. This work explores different data reduction schemes and designs a new approach that requires only a few CT scans of a phantom. For this work, the leave-one-out likelihood (LOOL) method developed by Hoffbeck and Landgrebe is studied as an efficient method of estimating the covariance matrices needed to compute CHO performance. Three different kinds of approaches are included in the study: a conventional CHO estimation technique with a large sample size, a conventional technique with fewer samples, and the new LOOL-based approach with fewer samples. The mean value and standard deviation of area under ROC curve (AUC) is estimated by shuffle method. Both simulation and real data results indicate that an 80% data reduction can be achieved without loss of accuracy. This data reduction makes the proposed approach a practical tool for routine CT system assessment.

  4. Four-dimensional evaluation of regional air quality models

    EPA Science Inventory

    We present highlights of the results obtained in the third phase of the Air Quality Model Evaluation International Initiative (AQMEII3). Activities in AQMEII3 were focused on evaluating the performance of global, hemispheric and regional modeling systems over Europe and North Ame...

  5. Online hyperspectral imaging system for evaluating quality of agricultural products

    NASA Astrophysics Data System (ADS)

    Mo, Changyeun; Kim, Giyoung; Lim, Jongguk

    2017-06-01

    The consumption of fresh-cut agricultural produce in Korea has been growing. The browning of fresh-cut vegetables that occurs during storage and foreign substances such as worms and slugs are some of the main causes of consumers' concerns with respect to safety and hygiene. The purpose of this study is to develop an on-line system for evaluating quality of agricultural products using hyperspectral imaging technology. The online evaluation system with single visible-near infrared hyperspectral camera in the range of 400 nm to 1000 nm that can assess quality of both surfaces of agricultural products such as fresh-cut lettuce was designed. Algorithms to detect browning surface were developed for this system. The optimal wavebands for discriminating between browning and sound lettuce as well as between browning lettuce and the conveyor belt were investigated using the correlation analysis and the one-way analysis of variance method. The imaging algorithms to discriminate the browning lettuces were developed using the optimal wavebands. The ratio image (RI) algorithm of the 533 nm and 697 nm images (RI533/697) for abaxial surface lettuce and the ratio image algorithm (RI533/697) and subtraction image (SI) algorithm (SI538-697) for adaxial surface lettuce had the highest classification accuracies. The classification accuracy of browning and sound lettuce was 100.0% and above 96.0%, respectively, for the both surfaces. The overall results show that the online hyperspectral imaging system could potentially be used to assess quality of agricultural products.

  6. CMAQ Involvement in Air Quality Model Evaluation International Initiative

    EPA Pesticide Factsheets

    Description of Air Quality Model Evaluation International Initiative (AQMEII). Different chemical transport models are applied by different groups over North America and Europe and evaluated against observations.

  7. Quality Rating and Improvement System State Evaluations and Research

    ERIC Educational Resources Information Center

    Ferguson, Daniel

    2016-01-01

    A quality rating and improvement system (QRIS) is a method used by states and local jurisdictions to assess the level of quality of child care and early education programs, improve quality, and convey quality ratings to parents and other consumers. A typical QRIS incorporates the following components: quality standards for participating providers;…

  8. A simple method for low-contrast detectability, image quality and dose optimisation with CT iterative reconstruction algorithms and model observers.

    PubMed

    Bellesi, Luca; Wyttenbach, Rolf; Gaudino, Diego; Colleoni, Paolo; Pupillo, Francesco; Carrara, Mauro; Braghetti, Antonio; Puligheddu, Carla; Presilla, Stefano

    2017-01-01

    The aim of this work was to evaluate detection of low-contrast objects and image quality in computed tomography (CT) phantom images acquired at different tube loadings (i.e. mAs) and reconstructed with different algorithms, in order to find appropriate settings to reduce the dose to the patient without any image detriment. Images of supraslice low-contrast objects of a CT phantom were acquired using different mAs values. Images were reconstructed using filtered back projection (FBP), hybrid and iterative model-based methods. Image quality parameters were evaluated in terms of modulation transfer function; noise, and uniformity using two software resources. For the definition of low-contrast detectability, studies based on both human (i.e. four-alternative forced-choice test) and model observers were performed across the various images. Compared to FBP, image quality parameters were improved by using iterative reconstruction (IR) algorithms. In particular, IR model-based methods provided a 60% noise reduction and a 70% dose reduction, preserving image quality and low-contrast detectability for human radiological evaluation. According to the model observer, the diameters of the minimum detectable detail were around 2 mm (up to 100 mAs). Below 100 mAs, the model observer was unable to provide a result. IR methods improve CT protocol quality, providing a potential dose reduction while maintaining a good image detectability. Model observer can in principle be useful to assist human performance in CT low-contrast detection tasks and in dose optimisation.

  9. Quality evaluation of Yin Chen Hao Tang extract based on fingerprint chromatogram and simultaneous determination of five bioactive constituents.

    PubMed

    Wang, Xijun; Lv, Haitao; Sun, Hui; Jiang, Xingang; Wu, Zeming; Sun, Wenjun; Wang, Ping; Liu, Lian; Bi, Kaishun

    2008-01-01

    A completely validated method based on HPLC coupled with photodiode array detector (HPLC-UV) was described for evaluating and controlling quality of Yin Chen Hao Tang extract (YCHTE). First, HPLC-UV fingerprint chromatogram of YCHTE was established for preliminarily elucidating amount and chromatographic trajectory of chemical constituents in YCHTE. Second, for the first time, five mainly bioactive constituents in YCHTE were simultaneously determined based on fingerprint chromatogram for furthermore controlling the quality of YCHTE quantitatively. The developed method was applied to analyze 12 batches of YCHTE samples which consisted of herbal drugs from different places of production, showed acceptable linearity, intraday (RSD <5%), interday precision (RSD <4.80%), and accuracy (RSD <2.80%). As a result, fingerprint chromatogram determined 15 representative general fingerprint peaks, and the fingerprint chromatogram resemblances are all better than 0.9996. The contents of five analytes in different batches of YCHTE samples do not indicate significant difference. So, it is concluded that the developed HPLC-UV method is a more fully validated and complete method for evaluating and controlling the quality of YCHTE.

  10. [Quality management in a clinical research facility: Evaluation of changes in quality in-house figures and the appraisal of in-house quality indicators].

    PubMed

    Aden, Bile; Allekotte, Silke; Mösges, Ralph

    2016-12-01

    For long-term maintenance and improvement of quality within a clinical research institute, the implementation and certification of a quality management system is suitable. Due to the implemented quality management system according to the still valid DIN EN ISO 9001:2008 desired quality objectives are achieved effectively. The evaluation of quality scores and the appraisal of in-house quality indicators make an important contribution in this regard. In order to achieve this and draw quality assurance conclusions, quality indicators as sensible and sensitive as possible are developed. For this, own key objectives, the retrospective evaluation of quality scores, a prospective follow-up and also discussions establish the basis. In the in-house clinical research institute the measures introduced by the quality management led to higher efficiency in work processes, improved staff skills, higher customer satisfaction and overall to more successful outcomes in relation to the self-defined key objectives. Copyright © 2016. Published by Elsevier GmbH.

  11. General Quality Control (QC) Guidelines for SAM Methods

    EPA Pesticide Factsheets

    Learn more about quality control guidelines and recommendations for the analysis of samples using the methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  12. An Innovative Method for Monitoring Food Quality and the Healthfulness of Consumers’ Grocery Purchases

    PubMed Central

    Tran, Le-Thuy T.; Brewster, Philip J.; Chidambaram, Valliammai; Hurdle, John F.

    2017-01-01

    This study presents a method laying the groundwork for systematically monitoring food quality and the healthfulness of consumers’ point-of-sale grocery purchases. The method automates the process of identifying United States Department of Agriculture (USDA) Food Patterns Equivalent Database (FPED) components of grocery food items. The input to the process is the compact abbreviated descriptions of food items that are similar to those appearing on the point-of-sale sales receipts of most food retailers. The FPED components of grocery food items are identified using Natural Language Processing techniques combined with a collection of food concept maps and relationships that are manually built using the USDA Food and Nutrient Database for Dietary Studies, the USDA National Nutrient Database for Standard Reference, the What We Eat In America food categories, and the hierarchical organization of food items used by many grocery stores. We have established the construct validity of the method using data from the National Health and Nutrition Examination Survey, but further evaluation of validity and reliability will require a large-scale reference standard with known grocery food quality measures. Here we evaluate the method’s utility in identifying the FPED components of grocery food items available in a large sample of retail grocery sales data (~190 million transaction records). PMID:28475153

  13. The Usability of SEEQ in Quality Evaluation of Arabic Secondary Education in Malaysia

    ERIC Educational Resources Information Center

    al-Muslim, M.; Arifin, Zamri

    2015-01-01

    Evaluation of the quality of Arabic education in Malaysia needs to be conducted on a continuous basis to achieve the objectives of Arabic education. Student Evaluation of Education Quality (SEEQ) was proposed as one of the evaluation instruments of the quality of Arabic education. This study aimed to evaluate the usability of SEEQ in the context…

  14. Two Methods of Automatic Evaluation of Speech Signal Enhancement Recorded in the Open-Air MRI Environment

    NASA Astrophysics Data System (ADS)

    Přibil, Jiří; Přibilová, Anna; Frollo, Ivan

    2017-12-01

    The paper focuses on two methods of evaluation of successfulness of speech signal enhancement recorded in the open-air magnetic resonance imager during phonation for the 3D human vocal tract modeling. The first approach enables to obtain a comparison based on statistical analysis by ANOVA and hypothesis tests. The second method is based on classification by Gaussian mixture models (GMM). The performed experiments have confirmed that the proposed ANOVA and GMM classifiers for automatic evaluation of the speech quality are functional and produce fully comparable results with the standard evaluation based on the listening test method.

  15. Quality Assessment of Economic Evaluations of Suicide and Self-Harm Interventions.

    PubMed

    Bustamante Madsen, Lizell; Eddleston, Michael; Schultz Hansen, Kristian; Konradsen, Flemming

    2018-03-01

    Death following self-harm constitutes a major global public health challenge and there is an urgent need for governments to implement cost-effective, national suicide prevention strategies. To conduct a systematic review and quality appraisal of the economic evaluations of interventions aimed at preventing suicidal behavior. A systematic literature search was performed in several literature databases to identify relevant articles published from 2003 to 2016. Drummond's 10-item appraisal tool was used to assess the methodological quality of the included studies. In total, 25 documents encompassing 30 economic evaluations were included in the review. Of the identified evaluations, 10 studies were found to be of poor quality, 14 were of average quality, and six studies were considered of good quality. The majority of evaluations found the interventions to be cost-effective. Several limitations were identified and discussed in the article. A notable few economic evaluations were identified. The studies were diverse, primarily set in high-income countries, and often based on modeling, emphasizing the need for more primary research into the topic. The discussion of suicide and self-harm prevention should be as nuanced as possible, including health economics along with cultural, social, and political aspects.

  16. Towards the Real-Time Evaluation of Collaborative Activities: Integration of an Automatic Rater of Collaboration Quality in the Classroom from the Teacher's Perspective

    ERIC Educational Resources Information Center

    Chounta, Irene-Angelica; Avouris, Nikolaos

    2016-01-01

    This paper presents the integration of a real time evaluation method of collaboration quality in a monitoring application that supports teachers in class orchestration. The method is implemented as an automatic rater of collaboration quality and studied in a real time scenario of use. We argue that automatic and semi-automatic methods which…

  17. [Efficiency versus quality in the NHS, in Portugal: methodologies for evaluation].

    PubMed

    Giraldes, Maria do Rosário

    2008-01-01

    To proceed to the evaluation of the efficiency and quality in the NHS, based in methodologies of evaluation of management, indicators of benchmarking and indicators of process and outcome. The 1980 and 1990 decades have seen the proliferation of all forms of process indicators as a way to control health services. It is not a coincidence that the increase in managed care has been accompanied by an explosion of process indicators, as it has happened in the health system of the USA. More recently the attention has turned away from measures of performance, which measure the process (what has been done) to those which measure outcomes (what was the result). Quality indicators have been developed in Europe, first to be used in hospitals, but also to be used in primary health care. Conceptually the justification for the introduction of process indicators comes from the principle that their use will reinforce a modification in the quality of the proceedings, which will give origin to better outcomes as well at population level, as resource saving. Outcome indicators compared with process indicators in health care shows that process indicators have the advantage of being more sensitive than outcome indicators to differences in the quality. Optimizing health care quality has the objective of establishing a quantitative relationship between the quality of the health services and cost-effectiveness. To identify quality indicators and benchmarking and to implement plans to measure the quality of health care. In a study made in a group of senior GP, in the UK, with the objective of determining which process indicators better reflect the quality of the services in primary health care services a Delphi method was used. Only seven indicators were chosen by 75% of the respondents: the percentage of eligible patients receiving cervical screening; the percentage of generic prescribing; the percentage of eligible patients receiving childhood immunization; the percentage of eligible

  18. A Tentative Study on the Evaluation of Community Health Service Quality*

    NASA Astrophysics Data System (ADS)

    Ma, Zhi-qiang; Zhu, Yong-yue

    Community health service is the key point of health reform in China. Based on pertinent studies, this paper constructed an indicator system for the community health service quality evaluation from such five perspectives as visible image, reliability, responsiveness, assurance and sympathy, according to service quality evaluation scale designed by Parasuraman, Zeithaml and Berry. A multilevel fuzzy synthetical evaluation model was constructed to evaluate community health service by fuzzy mathematics theory. The applicability and maneuverability of the evaluation indicator system and evaluation model were verified by empirical analysis.

  19. The impact of cooking methods on the nutritional quality and safety of chicken breaded nuggets.

    PubMed

    Gonçalves Albuquerque, Tânia; Oliveira, M Beatriz P P; Sanches-Silva, Ana; Cristina Bento, Ana; Costa, Helena S

    2016-06-15

    The impact of cooking methods (industrial pre-frying, deep-fat frying and baking) on the nutritional quality and safety of chicken breaded nugget samples from supermarket and commercial brands was evaluated. The changes in the quality characteristics (nutritional composition, fatty acids profile, cholesterol and salt) of the fried food and frying oil, after ten consecutive frying operations, were evaluated. The total fat content of nuggets varied between 10.9 and 22.7 g per 100 g of edible portion and the salt content ranged from 0.873 to 1.63 g per 100 g. Taking into account one portion of nuggets, the daily intake of salt can reach 49%, which can have a significant impact on the health of those who regularly consume this type of food, especially considering the prevalence of hypertension around the world. The analysed chicken breaded nuggets are rich in unsaturated fatty acids, which have been related with potential health benefits, namely regarding cardiovascular diseases. The cholesterol content of baked samples was two times higher when compared with the fried ones. The trans fatty acids and polar compounds contents of the frying oil used for frying significantly increased, but the values were still away from the maximum recommended by legal entities for its rejection. From a nutritional point of view, it is possible to conclude that the applied cooking methods can significantly influence the nutritional quality and safety of the analysed chicken breaded nuggets. This study will contribute to important knowledge on how the applied cooking methods can change the nutritional quality and safety of foods, namely of chicken nuggets, and can be very useful for dietary recommendations and nutritional assessment.

  20. 21 CFR 26.41 - Exchange and endorsement of quality system evaluation reports.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 1 2014-04-01 2014-04-01 false Exchange and endorsement of quality system... DEVICE QUALITY SYSTEM AUDIT REPORTS, AND CERTAIN MEDICAL DEVICE PRODUCT EVALUATION REPORTS: UNITED STATES... endorsement of quality system evaluation reports. (a) Listed European Community (EC) conformity assessment...

  1. 21 CFR 26.41 - Exchange and endorsement of quality system evaluation reports.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 1 2011-04-01 2011-04-01 false Exchange and endorsement of quality system... DEVICE QUALITY SYSTEM AUDIT REPORTS, AND CERTAIN MEDICAL DEVICE PRODUCT EVALUATION REPORTS: UNITED STATES... endorsement of quality system evaluation reports. (a) Listed European Community (EC) conformity assessment...

  2. 21 CFR 26.41 - Exchange and endorsement of quality system evaluation reports.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 1 2013-04-01 2013-04-01 false Exchange and endorsement of quality system... DEVICE QUALITY SYSTEM AUDIT REPORTS, AND CERTAIN MEDICAL DEVICE PRODUCT EVALUATION REPORTS: UNITED STATES... endorsement of quality system evaluation reports. (a) Listed European Community (EC) conformity assessment...

  3. 21 CFR 26.41 - Exchange and endorsement of quality system evaluation reports.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 1 2012-04-01 2012-04-01 false Exchange and endorsement of quality system... DEVICE QUALITY SYSTEM AUDIT REPORTS, AND CERTAIN MEDICAL DEVICE PRODUCT EVALUATION REPORTS: UNITED STATES... endorsement of quality system evaluation reports. (a) Listed European Community (EC) conformity assessment...

  4. Patients’ perceived value of pharmacy quality measures: a mixed-methods study

    PubMed Central

    Shiyanbola, Olayinka O; Mort, Jane R

    2015-01-01

    Objective To describe patients’ perceived value and use of quality measures in evaluating and choosing community pharmacies. Design Focus group methodology was combined with a survey tool. During the focus groups, participants assessed the value of the Pharmacy Quality Alliance's quality measures in evaluating and choosing a pharmacy. Also, participants completed questionnaires rating their perceived value of quality measures in evaluating a pharmacy (1 being low value and 5 being high) or choosing a pharmacy (yes/no). Thematic analysis and descriptive statistics were used to analyse the focus groups and surveys, respectively. Setting Semistructured focus groups were conducted in a private meeting space of an urban and a rural area of a Mid-western State in the USA. Participants Thirty-four adults who filled prescription medications in community pharmacies for a chronic illness were recruited in community pharmacies, senior centres and public libraries. Results While comments indicated that all measures were important, medication safety measures (eg, drug-drug interactions) were valued more highly than others. Rating of quality measure utility in evaluating a pharmacy ranged from a mean of 4.88 (‘drug-drug interactions’) to a mean of 4.0 (‘absence of controller therapy for patients with asthma’). Patients were hesitant to use quality information in choosing a pharmacy (depending on the participant's location) but might consider if moving to a new area or having had a negative pharmacy experience. Use of select quality measures to choose a pharmacy ranged from 97.1% of participants using ‘drug-drug interactions’ (medication safety measure) to 55.9% using ‘absence of controller therapy for patients with asthma’. Conclusions The study participants valued quality measures in evaluating and selecting a community pharmacy, with medication safety measures valued highest. The participants reported that the quality measures would not typically cause a

  5. Evaluation of air quality indicators in Alberta, Canada - An international perspective.

    PubMed

    Bari, Md Aynul; Kindzierski, Warren B

    2016-01-01

    There has been an increase in oil sands development in northern Alberta, Canada and an overall increase in economic activity in the province in recent years. An evaluation of the state of air quality was conducted in four Alberta locations - urban centers of Calgary and Edmonton, and smaller communities of Fort McKay and Fort McMurray in the Athabasca Oil Sands Region (AOSR). Concentration trends, diurnal hourly and monthly average concentration profiles, and exceedances of provincial, national and international air quality guidelines were assessed for several criteria air pollutants over the period 1998 to 2014. Two methods were used to evaluate trends. Parametric analysis of annual median 1h concentrations and non-parametric analysis of annual geometric mean 1h concentrations showed consistent decreasing trends for NO2 and SO2 (<1ppb per year), CO (<0.1ppm per year) at all stations, decreasing for THC (<0.1ppm per year) and increasing for O3 (≤0.52ppb per year) at most stations and unchanged for PM2.5 at all stations in Edmonton and Calgary over a 17-year period. Little consistency in trends was observed among the methods for the same air pollutants other than for THC (increasing in Fort McKay <0.1ppm per year and no trend in Fort McMurray), PM2.5 in Fort McKay and Fort McMurray (no trend) and CO (decreasing <0.1ppm per year in Fort McMurray) over the same period. Levels of air quality indicators at the four locations were compared with other Canadian and international urban areas to judge the current state of air quality. Median and annual average concentrations for Alberta locations tended to be the smallest in Fort McKay and Fort McMurray. Other than for PM2.5, Calgary and Edmonton tended to have median and annual average concentrations comparable to and/or below that of larger populated Canadian and U.S. cities, depending upon the air pollutant. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. [A quality evaluation tableau for health institutions: an educational tool].

    PubMed

    Moll, Marie Christine; Decavel, Frédérique; Merlet, Christine

    2009-09-01

    For a few years, health institutions have had to comply with the certification and the need to establish the new governance. Thanks to the accreditation version 2 (obtained in 2005), the elaboration of the hospital project (adopted in October, 2006) and the organization in poles since 2006, the quality oriented management became a priority axis at the University Hospital of Angers. The strategic adaptation to quality requirements leads to develop the hospital management, more especially at the level of the clinical, medico technical and administrative poles. The elements of the hospital project including the part about the quality, risk and evaluation aim at being adapted by every pole according to the level of its project. This adaptation which is imposed to each pole manager requires a practical and educational accompaniment allowing at the same time to realize a diagnosis of the progress of the quality approach, a measure of the impact of the global impregnation within the institution and a comparison between pole. A eight axis dashboard with criteria and a user guide were developed from certification ISO 9001, the EFQM manual and the certification manual version 2 of the Healthcare High Authorities. The criteria are transcribed in an EXCEL grid ready to use. Succeeding in estimating your own quality system means that you demonstrate the maturity of the quality approach. The results of this evaluation confirmed those of the certification. The dashboard is a management structuring tool at the service of the multidisciplinary team. Two considerations emerge from these results: First of all, for the hospital top management, the axes to be improved emerge as a priority to determine and target the next annual action plans. The results also allow to support the auto evaluation for the certification version 2010 planned in January of the same year. It is a pragmatic tool which allows auto evaluation and comparison to estimate the pole performances. It is a strategic

  7. Adapting total quality management for general practice: evaluation of a programme.

    PubMed Central

    Lawrence, M; Packwood, T

    1996-01-01

    OBJECTIVE: Assessment of the benefits and limitations of a quality improvement programme based on total quality management principles in general practice over a period of one year (October 1993-4). DESIGN: Questionnaires to practice team members before any intervention and after one year. Three progress reports completed by facilitators at four month intervals. Semistructured interviews with a sample of staff from each practice towards the end of the year. SETTING: 18 self selected practices from across the former Oxford Region. Three members of each practice received an initial residential course and three one day seminars during the year. Each practice was supported by a facilitator from their Medical Audit Advisory Group. MEASURES: Extent of understanding and implementation of quality improvement methodology. Number, completeness, and evaluation of quality improvement projects. Practice team members' attitudes to and involvement in team working and quality improvement. RESULTS: 16 of the 18 practices succeeded in implementing the quality improvement methods. 48 initiatives were considered and staff involvement was broad. Practice members showed increased involvement in, and appreciation of, strategic planning and team working, and satisfaction from improved patients services. 11 of the practices intend to continue with the methodology. The commonest barrier expressed was time. CONCLUSION: Quality improvement programmes based on total quality management principles produce beneficial changes in service delivery and team working in most general practices. It is incompatible with traditional doctor centred practice. The methodology needs to be adapted for primary care to avoid quality improvement being seen as separate from routine activity, and to save time. PMID:10161529

  8. Image processing system performance prediction and product quality evaluation

    NASA Technical Reports Server (NTRS)

    Stein, E. K.; Hammill, H. B. (Principal Investigator)

    1976-01-01

    The author has identified the following significant results. A new technique for image processing system performance prediction and product quality evaluation was developed. It was entirely objective, quantitative, and general, and should prove useful in system design and quality control. The technique and its application to determination of quality control procedures for the Earth Resources Technology Satellite NASA Data Processing Facility are described.

  9. DNA decontamination methods for internal quality management in clinical PCR laboratories.

    PubMed

    Wu, Yingping; Wu, Jianyong; Zhang, Zhihui; Cheng, Chen

    2018-03-01

    The polymerase chain reaction (PCR) technique, one of the most commonly applied methods in diagnostic and molecular biology, has a frustrating downside: the occurrence of false-positive signals due to contamination. In previous research, various DNA decontamination methods have been developed to overcome this limitation. Unfortunately, the use of random or poorly focused sampling methods for monitoring air and/or object surfaces leads to the incomplete elimination during decontamination procedures. We herein attempted to develop a novel DNA decontamination method (environmental surveillance, including surface and air sampling) and quality management program for clinical molecular diagnostic laboratories (or clinical PCR laboratories). Here, we performed a step-by-step evaluation of current DNA decontamination methods and developed an effective procedure for assessing the presence of decontaminating DNA via PCR analysis. Performing targeted environmental surveillance by sampling, which reached optimal performance over 2 weeks, and the decontamination process had been verified as reliable. Additionally, the process was validated to not affect PCR amplification efficiency based on a comparative study. In this study, effective guidelines for DNA decontamination were developed. The method employed ensured that surface DNA contamination could be effectively identified and eliminated. Furthermore, our study highlighted the importance of overall quality assurance and good clinical laboratory practices for preventing contamination, which are key factors for compliance with regulatory or accreditation requirements. Taken together, we provided the evidence that the presented scheme ranged from troubleshooting to the elimination of surface contamination, could serve as critical foundation for developing regular environmental surveillance guidelines for PCR laboratories. © 2017 Wiley Periodicals, Inc.

  10. Valid methods: the quality assurance of test method development, validation, approval, and transfer for veterinary testing laboratories.

    PubMed

    Wiegers, Ann L

    2003-07-01

    Third-party accreditation is a valuable tool to demonstrate a laboratory's competence to conduct testing. Accreditation, internationally and in the United States, has been discussed previously. However, accreditation is only I part of establishing data credibility. A validated test method is the first component of a valid measurement system. Validation is defined as confirmation by examination and the provision of objective evidence that the particular requirements for a specific intended use are fulfilled. The international and national standard ISO/IEC 17025 recognizes the importance of validated methods and requires that laboratory-developed methods or methods adopted by the laboratory be appropriate for the intended use. Validated methods are therefore required and their use agreed to by the client (i.e., end users of the test results such as veterinarians, animal health programs, and owners). ISO/IEC 17025 also requires that the introduction of methods developed by the laboratory for its own use be a planned activity conducted by qualified personnel with adequate resources. This article discusses considerations and recommendations for the conduct of veterinary diagnostic test method development, validation, evaluation, approval, and transfer to the user laboratory in the ISO/IEC 17025 environment. These recommendations are based on those of nationally and internationally accepted standards and guidelines, as well as those of reputable and experienced technical bodies. They are also based on the author's experience in the evaluation of method development and transfer projects, validation data, and the implementation of quality management systems in the area of method development.

  11. Benchmarking Data Sets for the Evaluation of Virtual Ligand Screening Methods: Review and Perspectives.

    PubMed

    Lagarde, Nathalie; Zagury, Jean-François; Montes, Matthieu

    2015-07-27

    Virtual screening methods are commonly used nowadays in drug discovery processes. However, to ensure their reliability, they have to be carefully evaluated. The evaluation of these methods is often realized in a retrospective way, notably by studying the enrichment of benchmarking data sets. To this purpose, numerous benchmarking data sets were developed over the years, and the resulting improvements led to the availability of high quality benchmarking data sets. However, some points still have to be considered in the selection of the active compounds, decoys, and protein structures to obtain optimal benchmarking data sets.

  12. Land quality evaluation based on sustainable development for gully erosion control and land consolidation project of Yan’ an, China

    NASA Astrophysics Data System (ADS)

    Wang, Jing; Han, Jichang; Zhang, Yang; Du, Yichun; Bai, Qingjun

    2018-01-01

    Based on the three land consolidation projects in Yan’an region, the differentiation of the soil capacity, texture, available nutrients, pH etc before and after land consolidation were analyzed, and a comprehensive evaluation of soil quality before and after consolidation was done in this study. The results show that: (1) After the gully-land consolidation, the soil capacity, nitrogen, available P, available K and conductivity are increased, while the organic matter and pH are decreased. With one-year’s cultivation, the soil capacity decreased and the organic matter increased. After the slope-land consolidation, the soil physical and chemical properties have similar trends with the gullies, but the change is more significant. (2)No matter for gully or slope, the soil quality declines where the land just get consolidated, and the slope has more significant declining. With one-year’s cultivation, the soil quality of the gully has more rapid recovery with one grade uplift. (3) The correlation coefficient method was used to give a comprehensive evaluation of the soil quality, to considerate of the changes of the coefficients of the factors and the evaluation object. The evaluation can well reflect the actual situation of the soil quality, give reference to the soil quality evaluation for consolidated land, and the results may provide basis for the performance evaluation of the Yan’an land consolidation projects.

  13. Narrative methods in quality improvement research

    PubMed Central

    Greenhalgh, T; Russell, J; Swinglehurst, D

    2005-01-01

    

 This paper reviews and critiques the different approaches to the use of narrative in quality improvement research. The defining characteristics of narrative are chronology (unfolding over time); emplotment (the literary juxtaposing of actions and events in an implicitly causal sequence); trouble (that is, harm or the risk of harm); and embeddedness (the personal story nests within a particular social, historical and organisational context). Stories are about purposeful action unfolding in the face of trouble and, as such, have much to offer quality improvement researchers. But the quality improvement report (a story about efforts to implement change), which is common, must be distinguished carefully from narrative based quality improvement research (focused systematic enquiry that uses narrative methods to generate new knowledge), which is currently none. We distinguish four approaches to the use of narrative in quality improvement research—narrative interview; naturalistic story gathering; organisational case study; and collective sense-making—and offer a rationale, describe how data can be collected and analysed, and discuss the strengths and limitations of each using examples from the quality improvement literature. Narrative research raises epistemological questions about the nature of narrative truth (characterised by sense-making and emotional impact rather than scientific objectivity), which has implications for how rigour should be defined (and how it might be achieved) in this type of research. We offer some provisional guidance for distinguishing high quality narrative research in a quality improvement setting from other forms of narrative account such as report, anecdote, and journalism. PMID:16326792

  14. A novel evaluation method for building construction project based on integrated information entropy with reliability theory.

    PubMed

    Bai, Xiao-ping; Zhang, Xi-wei

    2013-01-01

    Selecting construction schemes of the building engineering project is a complex multiobjective optimization decision process, in which many indexes need to be selected to find the optimum scheme. Aiming at this problem, this paper selects cost, progress, quality, and safety as the four first-order evaluation indexes, uses the quantitative method for the cost index, uses integrated qualitative and quantitative methodologies for progress, quality, and safety indexes, and integrates engineering economics, reliability theories, and information entropy theory to present a new evaluation method for building construction project. Combined with a practical case, this paper also presents detailed computing processes and steps, including selecting all order indexes, establishing the index matrix, computing score values of all order indexes, computing the synthesis score, sorting all selected schemes, and making analysis and decision. Presented method can offer valuable references for risk computing of building construction projects.

  15. Designing Excellence and Quality Model for Training Centers of Primary Health Care: A Delphi Method Study.

    PubMed

    Tabrizi, Jafar-Sadegh; Farahbakhsh, Mostafa; Shahgoli, Javad; Rahbar, Mohammad Reza; Naghavi-Behzad, Mohammad; Ahadi, Hamid-Reza; Azami-Aghdash, Saber

    2015-10-01

    Excellence and quality models are comprehensive methods for improving the quality of healthcare. The aim of this study was to design excellence and quality model for training centers of primary health care using Delphi method. In this study, Delphi method was used. First, comprehensive information were collected using literature review. In extracted references, 39 models were identified from 34 countries and related sub-criteria and standards were extracted from 34 models (from primary 39 models). Then primary pattern including 8 criteria, 55 sub-criteria, and 236 standards was developed as a Delphi questionnaire and evaluated in four stages by 9 specialists of health care system in Tabriz and 50 specialists from all around the country. Designed primary model (8 criteria, 55 sub-criteria, and 236 standards) were concluded with 8 criteria, 45 sub-criteria, and 192 standards after 4 stages of evaluations by specialists. Major criteria of the model are leadership, strategic and operational planning, resource management, information analysis, human resources management, process management, costumer results, and functional results, where the top score was assigned as 1000 by specialists. Functional results had the maximum score of 195 whereas planning had the minimum score of 60. Furthermore the most and the least sub-criteria was for leadership with 10 sub-criteria and strategic planning with 3 sub-criteria, respectively. The model that introduced in this research has been designed following 34 reference models of the world. This model could provide a proper frame for managers of health system in improving quality.

  16. A comprehensive quality evaluation method by FT-NIR spectroscopy and chemometric: Fine classification and untargeted authentication against multiple frauds for Chinese Ganoderma lucidum

    NASA Astrophysics Data System (ADS)

    Fu, Haiyan; Yin, Qiaobo; Xu, Lu; Wang, Weizheng; Chen, Feng; Yang, Tianming

    2017-07-01

    The origins and authenticity against frauds are two essential aspects of food quality. In this work, a comprehensive quality evaluation method by FT-NIR spectroscopy and chemometrics were suggested to address the geographical origins and authentication of Chinese Ganoderma lucidum (GL). Classification for 25 groups of GL samples (7 common species from 15 producing areas) was performed using near-infrared spectroscopy and interval-combination One-Versus-One least squares support vector machine (IC-OVO-LS-SVM). Untargeted analysis of 4 adulterants of cheaper mushrooms was performed by one-class partial least squares (OCPLS) modeling for each of the 7 GL species. After outlier diagnosis and comparing the influences of different preprocessing methods and spectral intervals on classification, IC-OVO-LS-SVM with standard normal variate (SNV) spectra obtained a total classification accuracy of 0.9317, an average sensitivity and specificity of 0.9306 and 0.9971, respectively. With SNV or second-order derivative (D2) spectra, OCPLS could detect at least 2% or more doping levels of adulterants for 5 of the 7 GL species and 5% or more doping levels for the other 2 GL species. This study demonstrates the feasibility of using new chemometrics and NIR spectroscopy for fine classification of GL geographical origins and species as well as for untargeted analysis of multiple adulterants.

  17. Methods of Writing Instruction Evaluation.

    ERIC Educational Resources Information Center

    Lamb, Bill H.

    The Writing Program Director at Johnson County Community College (Kansas) developed quantitative measures for writing instruction evaluation which can support that institution's growing interest in and support for peer collaboration as a means to improving instructional quality. The first process (Interaction Analysis) has an observer measure…

  18. Assessing QuADEM: Preliminary Notes on a New Method for Evaluating Online Language Learning Courseware

    ERIC Educational Resources Information Center

    Strobl, Carola; Jacobs, Geert

    2011-01-01

    In this article, we set out to assess QuADEM (Quality Assessment of Digital Educational Material), one of the latest methods for evaluating online language learning courseware. What is special about QuADEM is that the evaluation is based on observing the actual usage of the online courseware and that, from a checklist of 12 different components,…

  19. Human Health Water Quality Criteria and Methods for Toxics

    EPA Pesticide Factsheets

    Documents pertaining to Human Health Water Quality Criteria and Methods for Toxins. Includes 2015 Update for Water Quality Criteria, 2002 National Recommended Human Health Criteria, and 2000 EPA Methodology.

  20. Quality of Recovery Evaluation of the Protection Schemes for Fiber-Wireless Access Networks

    NASA Astrophysics Data System (ADS)

    Fu, Minglei; Chai, Zhicheng; Le, Zichun

    2016-03-01

    With the rapid development of fiber-wireless (FiWi) access network, the protection schemes have got more and more attention due to the risk of huge data loss when failures occur. However, there are few studies on the performance evaluation of the FiWi protection schemes by the unified evaluation criterion. In this paper, quality of recovery (QoR) method was adopted to evaluate the performance of three typical protection schemes (MPMC scheme, OBOF scheme and RPMF scheme) against the segment-level failure in FiWi access network. The QoR models of the three schemes were derived in terms of availability, quality of backup path, recovery time and redundancy. To compare the performance of the three protection schemes comprehensively, five different classes of network services such as emergency service, prioritized elastic service, conversational service, etc. were utilized by means of assigning different QoR weights. Simulation results showed that, for the most service cases, RPMF scheme was proved to be the best solution to enhance the survivability when planning the FiWi access network.

  1. Quality of care in the intensive care unit from the perspective of patient's relatives: development and psychometric evaluation of the consumer quality index 'R-ICU'.

    PubMed

    Rensen, Ans; van Mol, Margo M; Menheere, Ilse; Nijkamp, Marjan D; Verhoogt, Ellen; Maris, Bea; Manders, Willeke; Vloet, Lilian; Verharen, Lisbeth

    2017-01-24

    The quality standards of the Dutch Society of Intensive Care require monitoring of the satisfaction of patient's relatives with respect to care. Currently, no suitable instrument is available in the Netherlands to measure this. This study describes the development and psychometric evaluation of the questionnaire-based Consumer Quality Index 'Relatives in Intensive Care Unit' (CQI 'R-ICU'). The CQI 'R-ICU' measures the perceived quality of care from the perspective of patients' relatives, and identifies aspects of care that need improvement. The CQI 'R-ICU' was developed using a mixed method design. Items were based on quality of care aspects from earlier studies and from focus group interviews with patients' relatives. The time period for the data collection of the psychometric evaluation was from October 2011 until July 2012. Relatives of adult intensive care patients in one university hospital and five general hospitals in the Netherlands were approached to participate. Psychometric evaluation included item analysis, inter-item analysis, and factor analysis. Twelve aspects were noted as being indicators of quality of care, and were subsequently selected for the questionnaire's vocabulary. The response rate of patients' relatives was 81% (n = 455). Quality of care was represented by two clusters, each showing a high reliability: 'Communication' (α = .80) and 'Participation' (α = .84). Relatives ranked the following aspects for quality of care as most important: no conflicting information, information from doctors and nurses is comprehensive, and health professionals take patients' relatives seriously. The least important care aspects were: need for contact with peers, nuisance, and contact with a spiritual counsellor. Aspects that needed the most urgent improvement (highest quality improvement scores) were: information about how relatives can contribute to the care of the patient, information about the use of meal-facilities in the hospital, and

  2. Non-Destructive and rapid evaluation of staple foods quality by using spectroscopic techniques: A review.

    PubMed

    Su, Wen-Hao; He, Hong-Ju; Sun, Da-Wen

    2017-03-24

    Staple foods, including cereals, legumes, and root/tuber crops, dominate the daily diet of humans by providing valuable proteins, starch, oils, minerals, and vitamins. Quality evaluation of staple foods is primarily carried out on sensory (e.g. external defect, color), adulteration (e.g. species, origin), chemical (e.g. starch, proteins), mycotoxin (e.g. Fusarium toxin, aflatoxin), parasitic infection (e.g. weevil, beetle), and internal physiological (e.g. hollow heart, black heart) aspects. Conventional methods for the quality assessment of staple foods are always laborious, destructive, and time-consuming. Requirements for online monitoring of staple foods have been proposed to encourage the development of rapid, reagentless, and noninvasive techniques. Spectroscopic techniques, such as visible-infrared spectroscopy, Raman spectroscopy, nuclear magnetic resonance spectroscopy, and spectral imaging, have been introduced as promising analytical tools and applied for the quality evaluation of staple foods. This review summarizes the recent applications and progress of such spectroscopic techniques in determining various qualities of staple foods. Besides, challenges and future trends of these spectroscopic techniques are also presented.

  3. Measurement properties of existing clinical assessment methods evaluating scapular positioning and function. A systematic review.

    PubMed

    Larsen, Camilla Marie; Juul-Kristensen, Birgit; Lund, Hans; Søgaard, Karen

    2014-10-01

    The aims were to compile a schematic overview of clinical scapular assessment methods and critically appraise the methodological quality of the involved studies. A systematic, computer-assisted literature search using Medline, CINAHL, SportDiscus and EMBASE was performed from inception to October 2013. Reference lists in articles were also screened for publications. From 50 articles, 54 method names were identified and categorized into three groups: (1) Static positioning assessment (n = 19); (2) Semi-dynamic (n = 13); and (3) Dynamic functional assessment (n = 22). Fifteen studies were excluded for evaluation due to no/few clinimetric results, leaving 35 studies for evaluation. Graded according to the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN checklist), the methodological quality in the reliability and validity domains was "fair" (57%) to "poor" (43%), with only one study rated as "good". The reliability domain was most often investigated. Few of the assessment methods in the included studies that had "fair" or "good" measurement property ratings demonstrated acceptable results for both reliability and validity. We found a substantially larger number of clinical scapular assessment methods than previously reported. Using the COSMIN checklist the methodological quality of the included measurement properties in the reliability and validity domains were in general "fair" to "poor". None were examined for all three domains: (1) reliability; (2) validity; and (3) responsiveness. Observational evaluation systems and assessment of scapular upward rotation seem suitably evidence-based for clinical use. Future studies should test and improve the clinimetric properties, and especially diagnostic accuracy and responsiveness, to increase utility for clinical practice.

  4. Objective speech quality evaluation of real-time speech coders

    NASA Astrophysics Data System (ADS)

    Viswanathan, V. R.; Russell, W. H.; Huggins, A. W. F.

    1984-02-01

    This report describes the work performed in two areas: subjective testing of a real-time 16 kbit/s adaptive predictive coder (APC) and objective speech quality evaluation of real-time coders. The speech intelligibility of the APC coder was tested using the Diagnostic Rhyme Test (DRT), and the speech quality was tested using the Diagnostic Acceptability Measure (DAM) test, under eight operating conditions involving channel error, acoustic background noise, and tandem link with two other coders. The test results showed that the DRT and DAM scores of the APC coder equalled or exceeded the corresponding test scores fo the 32 kbit/s CVSD coder. In the area of objective speech quality evaluation, the report describes the development, testing, and validation of a procedure for automatically computing several objective speech quality measures, given only the tape-recordings of the input speech and the corresponding output speech of a real-time speech coder.

  5. Using the Delphi method to develop nursing-sensitive quality indicators for the NICU.

    PubMed

    Chen, Lin; Huang, Li-Hua; Xing, Mei-Yuan; Feng, Zhi-Xian; Shao, Le-Wen; Zhang, Mei-Yun; Shao, Rong-Ya

    2017-02-01

    To develop nursing-sensitive quality indicators consistent with current medical practices in Chinese neonatal intensive care units. The development of nursing-sensitive quality indicators has become a top priority in nursing management. To the best of our knowledge, there has been no objective, scientific and sensitive evaluation of the quality of neonatal intensive care unit nursing in China. A modified Delphi technique was used to seek opinions from experts about what should be used and prioritised as indicators of quality care in neonatal intensive care unit nursing. Based on a literature review, we identified 21 indicators of nursing-sensitive quality in the neonatal intensive care unit. Our group of 11 consultants chose 13 indicators to be discussed using the Delphi method. In October and November 2014, 39 neonatal intensive care unit experts in 18 tertiary hospitals spread across six provinces participated in two rounds of Delphi panels. Of the 13 indicators discussed, 11 were identified as indicators of nursing-sensitive quality in the neonatal intensive care unit: rate of nosocomial infections, rate of accidental endotracheal extubation, rate of errors in medication administration, rate of treatment for pain, rate of peripheral venous extravasation, rate of compliance with handwashing techniques, incidence of pressure ulcers, incidence of noise, the bed-to-care ratio, the proportion of nurses with greater than five years neonatal intensive care unit experience and incidence of retinopathy. The 11 neonatal intensive care unit nursing-sensitive indicators identified by the Delphi method integrated with basic Chinese practices provide a basis for nursing management and the monitoring of nursing quality. This study identified nursing-sensitive quality indicators for neonatal intensive care unit care that are suitable for current clinical practice in China. © 2016 John Wiley & Sons Ltd.

  6. Evaluation of health care service quality in Poland with the use of SERVQUAL method at the specialist ambulatory health care center

    PubMed Central

    Manulik, Stanisław; Rosińczuk, Joanna; Karniej, Piotr

    2016-01-01

    Introduction Service quality and customer satisfaction are very important components of competitive advantage in the health care sector. The SERVQUAL method is widely used for assessing the quality expected by patients and the quality of actually provided services. Objectives The main purpose of this study was to determine if patients from state and private health care facilities differed in terms of their qualitative priorities and assessments of received services. Materials and methods The study included a total of 412 patients: 211 treated at a state facility and 201 treated at a private facility. Each of the respondents completed a 5-domain, 22-item SERVQUAL questionnaire. The actual quality of health care services in both types of facilities proved significantly lower than expected. Results All the patients gave the highest scores to the domains constituting the core aspects of health care services. The private facility respondents had the highest expectations with regard to equipment, and the state facility ones regarding contacts with the medical personnel. Conclusion Health care quality management should be oriented toward comprehensive optimization in all domains, rather than only within the domain identified as the qualitative priority for patients of a given facility. PMID:27536075

  7. Effects of broiler carcass scalding and chilling methods on quality of early-deboned breast fillets.

    PubMed

    Zhuang, Hong; Bowker, Brian C; Buhr, R Jeff; Bourassa, Dianna V; Kiepper, Brian H

    2013-05-01

    The impact of scalding and chilling methods on quality of broiler breast fillets (pectoralis major) was evaluated. In 4 replications, 6- to 7-wk-old male and female broilers were slaughtered and scalded either at 60°C for 1.5 min (hard scalding) or 52.8°C for 3 min (soft scalding). Following evisceration, the carcasses were either air-chilled (0.5°C, 120 min) or immersion-chilled in water and ice (79 L/carcass, 0.5°C, 40 min, air agitated). Breast fillets were removed from the carcass within 4 h postmortem. Quality attributes including fillet color (both dorsal-bone and ventral-skin sides), pH, total moisture content, water-holding capacity (drip loss and cook loss), and Warner-Bratzler shear force were determined. Significant interactions between replication and scalding were found for pH, ventral side redness (a*) value, and cook loss and between replication and chilling for pH and ventral side a* and yellowness (b*) values. There were no interactions (P > 0.05) between chilling and scalding methods for any of the measurements. Immersion chilling resulted in higher (P < 0.05) ventral side lightness (L*) values, dorsal side b* values, drip loss, cook loss, and shear force compared with air chilling. No significant differences (P > 0.05) between the 2 scalding methods were observed for any of the quality attributes. These results indicate that broiler carcass chilling method has a much greater impact on quality of breast meat than scalding method and that the influence of chilling on breast meat quality is independent of scalding treatment.

  8. Effects of egg quality and method of incubation on the hatching success of channel X blue hybrid catfish eggs

    USDA-ARS?s Scientific Manuscript database

    The objective of this study was to evaluate the effects of egg quality of stripped eggs from channel catfish (Ictalurus punctatus) and method of incubation of fertilized hybrid catfish eggs on hatching success. Stripped eggs from 17 channel catfish females were evaluated in a 2 x 2 factorial...

  9. A bootstrap method for estimating uncertainty of water quality trends

    USGS Publications Warehouse

    Hirsch, Robert M.; Archfield, Stacey A.; DeCicco, Laura

    2015-01-01

    Estimation of the direction and magnitude of trends in surface water quality remains a problem of great scientific and practical interest. The Weighted Regressions on Time, Discharge, and Season (WRTDS) method was recently introduced as an exploratory data analysis tool to provide flexible and robust estimates of water quality trends. This paper enhances the WRTDS method through the introduction of the WRTDS Bootstrap Test (WBT), an extension of WRTDS that quantifies the uncertainty in WRTDS-estimates of water quality trends and offers various ways to visualize and communicate these uncertainties. Monte Carlo experiments are applied to estimate the Type I error probabilities for this method. WBT is compared to other water-quality trend-testing methods appropriate for data sets of one to three decades in length with sampling frequencies of 6–24 observations per year. The software to conduct the test is in the EGRETci R-package.

  10. Halal and kosher slaughter methods and meat quality: a review.

    PubMed

    Farouk, M M; Al-Mazeedi, H M; Sabow, A B; Bekhit, A E D; Adeyemi, K D; Sazili, A Q; Ghani, A

    2014-11-01

    There are many slaughter procedures that religions and cultures use around the world. The two that are commercially relevant are the halal and kosher methods practiced by Muslims and Jews respectively. The global trade in red meat and poultry produced using these two methods is substantial, thus the importance of the quality of the meat produced using the methods. Halal and kosher slaughter per se should not affect meat quality more than their industrial equivalents, however, some of their associated pre- and post-slaughter processes do. For instance, the slow decline in blood pressure following a halal pre-slaughter head-only stun and neck cut causes blood splash (ecchymosis) in a range of muscles and organs of slaughtered livestock. Other quality concerns include bruising, hemorrhages, skin discoloration and broken bones particularly in poultry. In addition to these conventional quality issues, the "spiritual quality" of the meat can also be affected when the halal and kosher religious requirements are not fully met during the slaughter process. The nature, causes, importance and mitigations of these and other quality issues related to halal and kosher slaughtering and meat production using these methods are the subjects of this review. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. [On-site evaluation of raw milk qualities by portable Vis/NIR transmittance technique].

    PubMed

    Wang, Jia-Hua; Zhang, Xiao-Wei; Wang, Jun; Han, Dong-Hai

    2014-10-01

    To ensure the material safety of dairy products, visible (Vis)/near infrared (NIR) spectroscopy combined with che- mometrics methods was used to develop models for fat, protein, dry matter (DM) and lactose on-site evaluation. A total of 88 raw milk samples were collected from individual livestocks in different years. The spectral of raw milk were measured by a porta- ble Vis/NIR spectrometer with diffused transmittance accessory. To remove the scatter effect and baseline drift, the diffused transmittance spectra were preprocessed by 2nd order derivative with Savitsky-Golay (polynomial order 2, data point 25). Changeable size moving window partial least squares (CSMWPLS) and genetic algorithms partial least squares (GAPLS) meth- ods were suggested to select informative regions for PLS calibration. The PLS and multiple linear regression (MLR) methods were used to develop models for predicting quality index of raw milk. The prediction performance of CSMWPLS models were similar to GAPLS models for fat, protein, DM and lactose evaluation, the root mean standard errors of prediction (RMSEP) were 0.115 6/0.103 3, 0.096 2/0.113 7, 0.201 3/0.123 7 and 0.077 4/0.066 8, and the relative standard deviations of prediction (RPD) were 8.99/10.06, 3.53/2.99, 5.76/9.38 and 1.81/2.10, respectively. Meanwhile, the MLR models were also cal- ibrated with 8, 10, 9 and 7 variables for fat, protein, DM and lactose, respectively. The prediction performance of MLR models was better than or close to PLS models. The MLR models to predict fat, protein, DM and lactose yielded the RMSEP of 0.107 0, 0.093 0, 0.136 0 and 0.065 8, and the RPD of 9.72, 3.66, 8.53 and 2.13, respectively. The results demonstrated the usefulness of Vis/NIR spectra combined with multivariate calibration methods as an objective and rapid method for the quality evaluation of complicated raw milks. And the results obtained also highlight the potential of portable Vis/NIR instruments for on-site assessing quality indexes of

  12. Quality of care in reproductive health programmes: monitoring and evaluation of quality improvement.

    PubMed

    Kwast, B E

    1998-12-01

    As 200 million women become pregnant every year, at least 30 million will develop life-threatening complications requiring emergency treatment at any level of society where they live. But it is a basic human right that pregnancy be made safe for all women as complications are mostly unpredictable. This requires reproductive health programmes which are responsive to women's and their families' needs and expectations on the one hand and enhancement of community participation, high quality obstetric services, and both provider collaboration and satisfaction on the other. Monitoring and evaluation of these facets need to be an integral part of any safe motherhood programme, not only to assess progress, but also to use this information for subsequent planning and implementation cycles of national programmes. Lessons learned from ten years' implementation of Safe Motherhood programmes indicate that process and outcome indicators are more feasible for short-term evaluation purposes than impact indicators, such as maternal mortality reduction. The former are described in this paper with relevant country examples. This is the third, and last, article in a series on quality of care in reproductive health programmes. The first (Kwast 1998a) contains an overview of concepts, assessments, barriers and improvements of quality of care. The second (Kwast 1998b) addresses education issues for quality improvement.

  13. Photomask quality evaluation using lithography simulation and multi-detector MVM-SEM

    NASA Astrophysics Data System (ADS)

    Ito, Keisuke; Murakawa, Tsutomu; Fukuda, Naoki; Shida, Soichi; Iwai, Toshimichi; Matsumoto, Jun; Nakamura, Takayuki; Matsushita, Shohei; Hagiwara, Kazuyuki; Hara, Daisuke

    2013-06-01

    The detection and management of mask defects which are transferred onto wafer becomes more important day by day. As the photomask patterns becomes smaller and more complicated, using Inverse Lithography Technology (ILT) and Source Mask Optimization (SMO) with Optical Proximity Correction (OPC). To evaluate photomask quality, the current method uses aerial imaging by optical inspection tools. This technique at 1Xnm node has a resolution limit because small defects will be difficult to detect. We already reported the MEEF influence of high-end photomask using wide FOV SEM contour data of "E3630 MVM-SEM®" and lithography simulator "TrueMask® DS" of D2S Inc. in the prior paper [1]. In this paper we evaluate the correlation between our evaluation method and optical inspection tools as ongoing assessment. Also in order to reduce the defect classification work, we can compose the 3 Dimensional (3D) information of defects and can judge whether repairs of defects would be required. Moreover, we confirm the possibility of wafer plane CD measurement based on the combination between E3630 MVM-SEM® and 3D lithography simulation.

  14. Reform of the Method for Evaluating the Teaching of Medical Linguistics to Medical Students

    ERIC Educational Resources Information Center

    Zhang, Hongkui; Wang, Bo; Zhang, Longlu

    2014-01-01

    Explorating reform of the teaching evaluation method for vocational competency-based education (CBE) curricula for medical students is a very important process in following international medical education standards, intensify ing education and teaching reforms, enhancing teaching management, and improving the quality of medical education. This…

  15. Extremely large magnetoresistance in a high-quality WTe2 grown by flux method

    NASA Astrophysics Data System (ADS)

    Tsumura, K.; Yano, R.; Kashiwaya, H.; Koyanagi, M.; Masubuchi, S.; Machida, T.; Namiki, H.; Sasagawa, T.; Kashiwaya, S.

    2018-03-01

    We have grown single crystals of WTe2 by a self-flux method and evaluated the quality of the crystals. A Hall bar-type device was fabricated from an as-exfoliated film on a Si substrate and longitudinal resistance Rxx was measured. Rxx increased with an applied perpendicular magnetic field without saturation and an extremely large magnetoresistance as high as 376,059 % was observed at 8.27 T and 1.7 K.

  16. Methods for collecting benthic invertebrate samples as part of the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Cuffney, Thomas F.; Gurtz, Martin E.; Meador, Michael R.

    1993-01-01

    Benthic invertebrate communities are evaluated as part of the ecological survey component of the U.S. Geological Survey's National Water-Quality Assessment Program. These biological data are collected along with physical and chemical data to assess water-quality conditions and to develop an understanding of the factors that affect water-quality conditions locally, regionally, and nationally. The objectives of benthic invertebrate community characterizations are to (1) develop for each site a list of tax a within the associated stream reach and (2) determine the structure of benthic invertebrate communities within selected habitats of that reach. A nationally consistent approach is used to achieve these objectives. This approach provides guidance on site, reach, and habitat selection and methods and equipment for qualitative multihabitat sampling and semi-quantitative single habitat sampling. Appropriate quality-assurance and quality-control guidelines are used to maximize the ability to analyze data within and among study units.

  17. [Alfalfa quality evaluation in the field by near-infrared reflectance spectroscopy].

    PubMed

    Xu, Rui-Xuan; Li, Dong-Ning; Yang, Dong-Hai; Lin, Jian-Hai; Xiang, Min; Zhang, Ying-Jun

    2013-11-01

    To explore the feasibility of using near-infrared reflectance spectroscopy (NIRS) to evaluate alfalfa quality rapidly in the field and try to find the appropriate machine and sample preparation method, the representative population of 170 fresh alfalfa samples collected from different regions with different stages and different cuts were scanned by a portable NIRS spectrometer (1 100 - 1 800 nm). This is the first time to build models of fresh alfalfa to rapidly estimate quality in the field for harvesting in time. The calibrations of dry matter (DM), crude protein (CP), neutral detergent fiber (NDF) and acid detergent fiber (ADF) were developed through the partial least squares regression (PLS). The determination coefficients of cross-validation (R2((CV)) were 0.831 4, 0.597 9, 0.803 6, 0.786 1 for DM, CP, NDF, ADF, respectively; the root mean standard error of cross-validation (RMSECV) were 1.241 1, 0.261 4, 0.990 3, 0.830 6; The determination coefficients of validation (R2(V)) were 0.815 0, 0.401 1, 0.784 9, 0.752 1 and the root mean standard errors of validation(RMSEP)were 1.06, 0.31, 0.95, 0.80 for DM, CP, NDF, ADF, respectively. For fresh alfalfa ,the calibration of DM, NDF, ADF can do rough quantitative analysis but the CP's calibration is failed. however, as CP in alfalfa hay is enough for animal and the DM, NDF and ADF is the crucial indicator for evaluating havest time, the model of DM, NDF and ADF can be used for evaluating the alfalfa quality rapidly in the field.

  18. [A method for auditing medical records quality: audit of 467 medical records within the framework of the medical information systems project quality control].

    PubMed

    Boulay, F; Chevallier, T; Gendreike, Y; Mailland, V; Joliot, Y; Sambuc, R

    1998-03-01

    Future hospital accreditation could take into account the quality of medical files. The objectives of this study is to test a method for auditing and evaluating the quality of the handing of medical files. We conducted a retrospective regional audit based on the frame of reference the National Agency for Medical Development and Evaluation, by using a sample of cases, stratified by establishment. In our region, the global budgets of 47 public and private hospitals participating in the public hospital service, are adjusted while keeping in mind the medicalised activity data (PMSI). This audit was proposed to the doctors of the Department of Medical Information on the occasion of the regulatory PMSI quality control. A total of 467 questionnaires were given by 39 of the 47 sollicited hospitals (83%). The methodological aspects (questionnaire, cooperative approach...) are discussed. The make-up of medical files can alos be improved by raising the percentage of the presence of important data or documents such as the reason for admission (74.1%), the surgery report (83.2%), and the hospitalisation report (66.6%). A system for classifying the paraclinical results is shared and systematic throughout the service or hospital in only 73.2% of cases. The quality of the handing of medical files seems problematic in our hospitals and actions for improving the quality should be undertaken as a priority.

  19. Evaluation of quality of life related to nutritional status.

    PubMed

    Wanden-Berghe, Carmina; Sanz-Valero, Javier; Escribà-Agüir, Vicenta; Castelló-Botia, Isabel; Guardiola-Wanden-Berghe, Rocio

    2009-04-01

    The way in which the quality of life related to health (HRQoL) is affected by the nutritional status of the patient is a subject of constant interest and permanent debate. The purpose of the present paper is to review those studies that relate HRQoL to nutritional status and examine the tools (questionnaires) that they use to investigate this relationship. A critical review of published studies was carried out via an investigation of the following databases: MEDLINE (via PubMed); EMBASE; The Cochrane Library; Cumulative Index to Nursing and Allied Health Literature (CINAHL); Institute for Scientific Information (ISI) Web of Science; Latin American and Caribbean Health Sciences Literature (LILACS); Spanish Health Sciences Bibliographic Index (IBECS). The search was carried out from the earliest date possible until July 2007.The medical subject heading terms used were 'quality of life', 'nutritional status' and 'questionnaires'. The articles had to contain at least one questionnaire that evaluated quality of life. Twenty-eight documents fulfilling the inclusion criteria were accepted, although none of them used a specific questionnaire to evaluate HRQoL related to nutritional status. However, some of them used a combination of generic questionnaires with the intention of evaluating the same. Only three studies selectively addressed the relationship between nutritional status and quality of life, this evaluation being performed not by means of specific questionnaires but by statistical analysis of data obtained via validated questionnaires.

  20. Identification of suitable fundus images using automated quality assessment methods.

    PubMed

    Şevik, Uğur; Köse, Cemal; Berber, Tolga; Erdöl, Hidayet

    2014-04-01

    Retinal image quality assessment (IQA) is a crucial process for automated retinal image analysis systems to obtain an accurate and successful diagnosis of retinal diseases. Consequently, the first step in a good retinal image analysis system is measuring the quality of the input image. We present an approach for finding medically suitable retinal images for retinal diagnosis. We used a three-class grading system that consists of good, bad, and outlier classes. We created a retinal image quality dataset with a total of 216 consecutive images called the Diabetic Retinopathy Image Database. We identified the suitable images within the good images for automatic retinal image analysis systems using a novel method. Subsequently, we evaluated our retinal image suitability approach using the Digital Retinal Images for Vessel Extraction and Standard Diabetic Retinopathy Database Calibration level 1 public datasets. The results were measured through the F1 metric, which is a harmonic mean of precision and recall metrics. The highest F1 scores of the IQA tests were 99.60%, 96.50%, and 85.00% for good, bad, and outlier classes, respectively. Additionally, the accuracy of our suitable image detection approach was 98.08%. Our approach can be integrated into any automatic retinal analysis system with sufficient performance scores.

  1. Evaluation of headache service quality indicators: pilot implementation in two specialist-care centres.

    PubMed

    Katsarava, Zaza; Gouveia, Raquel Gil; Jensen, Rigmor; Gaul, Charly; Schramm, Sara; Schoppe, Anja; Steiner, Timothy J

    2015-01-01

    Evaluating quality of health care is increasingly recognized as an important contributor to the advancement of health-care delivery. We recently developed a set of quality indicators for headache care, intended to be applicable across countries, cultures and settings so that deficiencies in headache care worldwide might be recognized and rectified. These indicators themselves require evaluation and proof of fitness for purpose. This pilot study begins this process. We tested the quality indicators in the tertiary headache centres of the University of Duisburg-Essen in Essen, Germany, and the Hospital da Luz in Lisbon, Portugal. Using seven previously-developed enquiry instruments, we interrogated health-care providers (HCPs), including doctors, nurses, psychologists and physiotherapists, as well as consecutive patients and their medical records. The questionnaires were easily understood by both HCPs and patients and were not unduly time-consuming. The results from the two headache centres were comparable despite their differences in structure, staffing and language. These findings met the purpose of the study. Diagnoses were made according to ICHD criteria and critically evaluated during follow-up. However, diagnostic diaries and instruments assessing burden and response to treatment were not always in place or routinely utilised. Triage systems adjusted waiting times to urgency of need. Treatment plans included pathways to other specialities. Patients felt welcomed, reassured and educated, and were mostly satisfied. Discussion points arose over inclusion of psychological therapies in treatment plans; over recording of outcomes; over indicators of efficiency and equitability (protocols to limit wastage of resources, systems to measure input costs and means of ensuring equal access to the services); and over protocols for reporting serious adverse events. This pilot study to assess feasibility of the methods and acceptability of the instruments of headache service

  2. Quality by Design: Multidimensional exploration of the design space in high performance liquid chromatography method development for better robustness before validation.

    PubMed

    Monks, K; Molnár, I; Rieger, H-J; Bogáti, B; Szabó, E

    2012-04-06

    Robust HPLC separations lead to fewer analysis failures and better method transfer as well as providing an assurance of quality. This work presents the systematic development of an optimal, robust, fast UHPLC method for the simultaneous assay of two APIs of an eye drop sample and their impurities, in accordance with Quality by Design principles. Chromatography software is employed to effectively generate design spaces (Method Operable Design Regions), which are subsequently employed to determine the final method conditions and to evaluate robustness prior to validation. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Defining Instructional Quality by Employing the Total Quality Management (TQM) Method: A Research Project.

    ERIC Educational Resources Information Center

    Croker, Robert E.; And Others

    The feasibility of using W. E. Deming's total quality management (TQM) method to define instructional quality was examined by surveying three groups of students attending Idaho State University's College of Education and School of Applied Technology: 31 students seeking cosmetology certification; 75 undergraduates pursuing degrees in corporate…

  4. Pragmatism, Evidence, and Mixed Methods Evaluation

    ERIC Educational Resources Information Center

    Hall, Jori N.

    2013-01-01

    Mixed methods evaluation has a long-standing history of enhancing the credibility of evaluation findings. However, using mixed methods in a utilitarian way implicitly emphasizes convenience over engaging with its philosophical underpinnings (Denscombe, 2008). Because of this, some mixed methods evaluators and social science researchers have been…

  5. Novel Approaches to Improve Iris Recognition System Performance Based on Local Quality Evaluation and Feature Fusion

    PubMed Central

    2014-01-01

    For building a new iris template, this paper proposes a strategy to fuse different portions of iris based on machine learning method to evaluate local quality of iris. There are three novelties compared to previous work. Firstly, the normalized segmented iris is divided into multitracks and then each track is estimated individually to analyze the recognition accuracy rate (RAR). Secondly, six local quality evaluation parameters are adopted to analyze texture information of each track. Besides, particle swarm optimization (PSO) is employed to get the weights of these evaluation parameters and corresponding weighted coefficients of different tracks. Finally, all tracks' information is fused according to the weights of different tracks. The experimental results based on subsets of three public and one private iris image databases demonstrate three contributions of this paper. (1) Our experimental results prove that partial iris image cannot completely replace the entire iris image for iris recognition system in several ways. (2) The proposed quality evaluation algorithm is a self-adaptive algorithm, and it can automatically optimize the parameters according to iris image samples' own characteristics. (3) Our feature information fusion strategy can effectively improve the performance of iris recognition system. PMID:24693243

  6. Novel approaches to improve iris recognition system performance based on local quality evaluation and feature fusion.

    PubMed

    Chen, Ying; Liu, Yuanning; Zhu, Xiaodong; Chen, Huiling; He, Fei; Pang, Yutong

    2014-01-01

    For building a new iris template, this paper proposes a strategy to fuse different portions of iris based on machine learning method to evaluate local quality of iris. There are three novelties compared to previous work. Firstly, the normalized segmented iris is divided into multitracks and then each track is estimated individually to analyze the recognition accuracy rate (RAR). Secondly, six local quality evaluation parameters are adopted to analyze texture information of each track. Besides, particle swarm optimization (PSO) is employed to get the weights of these evaluation parameters and corresponding weighted coefficients of different tracks. Finally, all tracks' information is fused according to the weights of different tracks. The experimental results based on subsets of three public and one private iris image databases demonstrate three contributions of this paper. (1) Our experimental results prove that partial iris image cannot completely replace the entire iris image for iris recognition system in several ways. (2) The proposed quality evaluation algorithm is a self-adaptive algorithm, and it can automatically optimize the parameters according to iris image samples' own characteristics. (3) Our feature information fusion strategy can effectively improve the performance of iris recognition system.

  7. Analytical Quality by Design in pharmaceutical quality assurance: Development of a capillary electrophoresis method for the analysis of zolmitriptan and its impurities.

    PubMed

    Orlandini, Serena; Pasquini, Benedetta; Caprini, Claudia; Del Bubba, Massimo; Pinzauti, Sergio; Furlanetto, Sandra

    2015-11-01

    A fast and selective CE method for the determination of zolmitriptan (ZOL) and its five potential impurities has been developed applying the analytical Quality by Design principles. Voltage, temperature, buffer concentration, and pH were investigated as critical process parameters that can influence the critical quality attributes, represented by critical resolution values between peak pairs, analysis time, and peak efficiency of ZOL-dimer. A symmetric screening matrix was employed for investigating the knowledge space, and a Box-Behnken design was used to evaluate the main, interaction, and quadratic effects of the critical process parameters on the critical quality attributes. Contour plots were drawn highlighting important interactions between buffer concentration and pH, and the gained information was merged into the sweet spot plots. Design space (DS) was established by the combined use of response surface methodology and Monte Carlo simulations, introducing a probability concept and thus allowing the quality of the analytical performances to be assured in a defined domain. The working conditions (with the interval defining the DS) were as follows: BGE, 138 mM (115-150 mM) phosphate buffer pH 2.74 (2.54-2.94); temperature, 25°C (24-25°C); voltage, 30 kV. A control strategy was planned based on method robustness and system suitability criteria. The main advantages of applying the Quality by Design concept consisted of a great increase of knowledge of the analytical system, obtained throughout multivariate techniques, and of the achievement of analytical assurance of quality, derived by probability-based definition of DS. The developed method was finally validated and applied to the analysis of ZOL tablets. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Water-quality and hydrogeologic data used to evaluate the effects of farming systems on ground-water quality at the Management Systems Evaluation Area near Princeton,Minnesota, 1991-95

    USGS Publications Warehouse

    Landon, M.K.; Delin, G.N.; Nelson, K.J.; Regan, C.P.; Lamb, J.A.; Larson, S.J.; Capel, P.D.; Anderson, J.L.; Dowdy, R.H.

    1997-01-01

    The Minnesota Management Systems Evaluation Area (MSEA) project was part of a multi-scale, inter-agency initiative to evaluate the effects of agricultural management systems on water quality in the midwest corn belt. The research area was located in the Anoka Sand Plain about 5 kilometers southwest of Princeton, Minnesota. The ground-water-quality monitoring network within and immediately surrounding the research area consisted of 73 observation wells and 25 multiport wells. The primary objectives of the ground-water monitoring program at the Minnesota MSEA were to: (1) determine the effects of three farming systems on ground-water quality, and (2) understand the processes and factors affecting the loading, transport, and fate of agricultural chemicals in ground water at the site. This report presents well construction, geologic, water-level, chemical application, water-quality, and quality-assurance data used to evaluate the effects of farming systems on ground-water quality during 1991-95.

  9. Evaluating radiographers' diagnostic accuracy in screen-reading mammograms: what constitutes a quality study?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Debono, Josephine C, E-mail: josephine.debono@bci.org.au; Poulos, Ann E; Westmead Breast Cancer Institute, Westmead, New South Wales

    The aim of this study was to first evaluate the quality of studies investigating the diagnostic accuracy of radiographers as mammogram screen-readers and then to develop an adapted tool for determining the quality of screen-reading studies. A literature search was used to identify relevant studies and a quality evaluation tool constructed by combining the criteria for quality of Whiting, Rutjes, Dinnes et al. and Brealey and Westwood. This constructed tool was then applied to the studies and subsequently adapted specifically for use in evaluating quality in studies investigating diagnostic accuracy of screen-readers. Eleven studies were identified and the constructed toolmore » applied to evaluate quality. This evaluation resulted in the identification of quality issues with the studies such as potential for bias, applicability of results, study conduct, reporting of the study and observer characteristics. An assessment of the applicability and relevance of the tool for this area of research resulted in adaptations to the criteria and the development of a tool specifically for evaluating diagnostic accuracy in screen-reading. This tool, with further refinement and rigorous validation can make a significant contribution to promoting well-designed studies in this important area of research and practice.« less

  10. Single-Site, Results-Level Evaluation of Quality Awareness Training.

    ERIC Educational Resources Information Center

    Murray, Brian; Raffaele, Gary C.

    1997-01-01

    An interrupted time-series design pooling 6 12-year series evaluated the long-term effects of a quality training intervention in a factory. Training positively affected quality of goods and dollar utility. Production process was an important contextual factor in assessing the effect size of the intervention. (SK)

  11. Methods for the evaluation of hospital cooperation activities (Systematic review protocol).

    PubMed

    Rotter, Thomas; Popa, Daniela; Riley, Beatrice; Ellermann, Tim; Ryll, Ulrike; Burazeri, Genc; Daemen, Piet; Peeters, Guy; Brand, Helmut

    2012-02-10

    Hospital partnerships, mergers and cooperatives are arrangements frequently seen as a means of improving health service delivery. Many of the assumptions used in planning hospital cooperatives are not stated clearly and are often based on limited or poor scientific evidence. This is a protocol for a systematic review, following the Cochrane EPOC methodology. The review aims to document, catalogue and synthesize the existing literature on the reported methods for the evaluation of hospital cooperation activities as well as methods of hospital cooperation. We will search the Database of Abstracts of Reviews of Effectiveness, the Effective Practice and Organisation of Care Register, the Cochrane Central Register of Controlled Trials and bibliographic databases including PubMed (via NLM), Web of Science, NHS EED, Business Source Premier (via EBSCO) and Global Health for publications that report on methods for evaluating hospital cooperatives, strategic partnerships, mergers, alliances, networks and related activities and methods used for such partnerships. The method proposed by the Cochrane EPOC group regarding randomized study designs, controlled clinical trials, controlled before and after studies, and interrupted time series will be followed. In addition, we will also include cohort, case-control studies, and relevant non-comparative publications such as case reports. We will categorize and analyze the review findings according to the study design employed, the study quality (low versus high quality studies) and the method reported in the primary studies. We will present the results of studies in tabular form. Overall, the systematic review aims to identify, assess and synthesize the evidence to underpin hospital cooperation activities as defined in this protocol. As a result, the review will provide an evidence base for partnerships, alliances or other fields of cooperation in a hospital setting. PROSPERO registration number: CRD42011001579.

  12. A review of image quality assessment methods with application to computational photography

    NASA Astrophysics Data System (ADS)

    Maître, Henri

    2015-12-01

    Image quality assessment has been of major importance for several domains of the industry of image as for instance restoration or communication and coding. New application fields are opening today with the increase of embedded power in the camera and the emergence of computational photography: automatic tuning, image selection, image fusion, image data-base building, etc. We review the literature of image quality evaluation. We pay attention to the very different underlying hypotheses and results of the existing methods to approach the problem. We explain why they differ and for which applications they may be beneficial. We also underline their limits, especially for a possible use in the novel domain of computational photography. Being developed to address different objectives, they propose answers on different aspects, which make them sometimes complementary. However, they all remain limited in their capability to challenge the human expert, the said or unsaid ultimate goal. We consider the methods which are based on retrieving the parameters of a signal, mostly in spectral analysis; then we explore the more global methods to qualify the image quality in terms of noticeable defects or degradation as popular in the compression domain; in a third field the image acquisition process is considered as a channel between the source and the receiver, allowing to use the tools of the information theory and to qualify the system in terms of entropy and information capacity. However, these different approaches hardly attack the most difficult part of the task which is to measure the quality of the photography in terms of aesthetic properties. To help in addressing this problem, in between Philosophy, Biology and Psychology, we propose a brief review of the literature which addresses the problematic of qualifying Beauty, present the attempts to adapt these concepts to visual patterns and initiate a reflection on what could be done in the field of photography.

  13. Quality evaluation in health care services based on customer-provider relationships.

    PubMed

    Eiriz, Vasco; Figueiredo, José António

    2005-01-01

    To develop a framework for evaluating the quality of Portuguese health care organisations based on the relationship between customers and providers, to define key variables related to the quality of health care services based on a review of the available literature, and to establish a conceptual framework in order to test the framework and variables empirically. Systematic review of the literature. Health care services quality should not be evaluated exclusively by customers. Given the complexity, ambiguity and heterogeneity of health care services, the authors develop a framework for health care evaluation based on the relationship between customers (patients, their relatives and citizens) and providers (managers, doctors, other technical staff and non-technical staff), and considering four quality items (customer service orientation, financial performance, logistical functionality and level of staff competence). This article identifies important changes in the Portuguese health care industry, such as the ownership of health care providers. At the same time, customers are changing their attitudes towards health care, becoming much more concerned and demanding of health services. These changes are forcing Portuguese private and public health care organisations to develop more marketing-oriented services. This article recognises the importance of quality evaluation of health care services as a means of increasing customer satisfaction and organisational efficiency, and develops a framework for health care evaluation based on the relationship between customers and providers.

  14. Evaluating the Psychometric Quality of Social Skills Measures: A Systematic Review

    PubMed Central

    Brown, Ted; Bourke-Taylor, Helen; Doma, Kenji; Leicht, Anthony

    2015-01-01

    Introduction Impairments in social functioning are associated with an array of adverse outcomes. Social skills measures are commonly used by health professionals to assess and plan the treatment of social skills difficulties. There is a need to comprehensively evaluate the quality of psychometric properties reported across these measures to guide assessment and treatment planning. Objective To conduct a systematic review of the literature on the psychometric properties of social skills and behaviours measures for both children and adults. Methods A systematic search was performed using four electronic databases: CINAHL, PsycINFO, Embase and Pubmed; the Health and Psychosocial Instruments database; and grey literature using PsycExtra and Google Scholar. The psychometric properties of the social skills measures were evaluated against the COSMIN taxonomy of measurement properties using pre-set psychometric criteria. Results Thirty-Six studies and nine manuals were included to assess the psychometric properties of thirteen social skills measures that met the inclusion criteria. Most measures obtained excellent overall methodological quality scores for internal consistency and reliability. However, eight measures did not report measurement error, nine measures did not report cross-cultural validity and eleven measures did not report criterion validity. Conclusions The overall quality of the psychometric properties of most measures was satisfactory. The SSBS-2, HCSBS and PKBS-2 were the three measures with the most robust evidence of sound psychometric quality in at least seven of the eight psychometric properties that were appraised. A universal working definition of social functioning as an overarching construct is recommended. There is a need for ongoing research in the area of the psychometric properties of social skills and behaviours instruments. PMID:26151362

  15. An Evaluation of Methods for Assessing Vulnerability of Army Installations toImpacts of Climate Change on Listed and At-Risk Species

    DTIC Science & Technology

    2017-07-01

    ER D C/ CE RL T R- 17 -2 5 Army Environmental Quality Technology An Evaluation of Methods for Assessing Vulnerability of Army...Evaluation of Methods for Assessing Vulnerability of Army Installations to Impacts of Climate Change on Listed and At-Risk Species Matthew G. Hohmann...their suitability for informing BRAC-related evaluations. Three recently developed methods for assessing the vulnerability of Army installations to

  16. [Development of an evaluation instrument for service quality in nursing homes].

    PubMed

    Lee, Jia; Ji, Eun Sun

    2011-08-01

    The purposes of this study were to identify the factors influencing service quality in nursing homes, and to develop an evaluation instrument for service quality. A three-phase process was employed for the study. 1) The important factors to evaluate the service quality in nursing homes were identified through a literature review, panel discussion and focus group interview, 2) the evaluation instrument was developed, and 3) validity and reliability of the study instrument were tested by factor analysis, Pearson correlation coefficient, Cronbach's α and Cohen's Kappa. Factor analysis showed that the factors influencing service quality in nursing homes were healthcare, diet/assistance, therapy, environment and staff. To improve objectivity of the instrument, quantitative as well as qualitative evaluation approaches were adopted. The study instrument was developed with 30 items and showed acceptable construct validity. The criterion-related validity was a Pearson correlation coefficient of .85 in 151 care facilities. The internal consistency was Cronbach's α=.95. The instrument has acceptable validity and a high degree of reliability. Staff in nursing homes can continuously improve and manage their services using the results of the evaluation instrument.

  17. Evaluation of milk quality in delivering sterilized milk with soft tank transportation system.

    PubMed

    Tsukamoto, C; Rula, Sa; Asano, H; Ando, K

    2009-09-01

    A new transportation system is proposed recently to improve the defects of liquid transportation by tank trucks. This method is called "soft tank transportation system"; a driver installs a sac-like container (soft tank), which is made from a tarpaulin with high-pressure resistant-waterproof zippers, in a general cargo vehicle. To evaluate the quality of sterilized milk by using the soft tank transportation system, ground and marine transportation for a long distance which took about 36 h from the shipper's loading to the receiver's unloading in a high-temperature summer season (average outside temperature was 33.4 degrees C) were carried out. Although the difference of milk temperature before and after the delivery varied from -0.7 to +1.4 degrees C, there was no difference in milk quality (fat, nonfat solids, total dissolved solids, and pH) and no coliform bacteria were detected. It can be evaluated that sterilized milk was carried in keeping good conditions by soft tank transportation system.

  18. Evaluating quality of care for patients with type 2 diabetes using electronic health record information in Mexico

    PubMed Central

    2012-01-01

    Background Several low and middle-income countries are implementing electronic health records (EHR). In the near future, EHRs could become an efficient tool to evaluate healthcare performance if appropriate indicators are developed. The aims of this study are: a) to develop quality of care indicators (QCIs) for type 2 diabetes (T2DM) in the Mexican Institute of Social Security (IMSS) health system; b) to determine the feasibility of constructing QCIs using the IMSS EHR data; and c) to evaluate the quality of care (QC) provided to IMSS patients with T2DM. Methods We used a three-stage mixed methods approach: a) development of QCIs following the RAND-UCLA method; b) EHR data extraction and construction of indicators; c) QC evaluation using EHR data from 25,130 T2DM patients who received care in 2009. Results We developed 18 QCIs, of which 14 were possible to construct using available EHR data. QCIs comprised both process of care and health outcomes. Several flaws in the EHR design and quality of data were identified. The indicators of process and outcomes of care suggested areas for improvement. For example, only 13.0% of patients were referred to an ophthalmologist; 3.9% received nutritional counseling; 63.2% of overweight/obese patients were prescribed metformin, and only 23% had HbA1c <7% (or plasma glucose ≤130 mg/dl). Conclusions EHR data can be used to evaluate QC. The results identified both strengths and weaknesses in the electronic information system as well as in the process and outcomes of T2DM care at IMSS. This information can be used to guide targeted interventions to improve QC. PMID:22672471

  19. Illinois' Forests, 2005: Statistics, Methods, and Quality Assurance

    Treesearch

    Susan J. Crocker; Charles J. Barnett; Mark A. Hatfield

    2013-01-01

    The first full annual inventory of Illinois' forests was completed in 2005. This report contains 1) descriptive information on methods, statistics, and quality assurance of data collection, 2) a glossary of terms, 3) tables that summarize quality assurance, and 4) a core set of tabular estimates for a variety of forest resources. A detailed analysis of inventory...

  20. Decision Dissonance: Evaluating an Approach to Measuring the Quality of Surgical Decision Making

    PubMed Central

    Fowler, Floyd J.; Gallagher, Patricia M.; Drake, Keith M.; Sepucha, Karen R.

    2013-01-01

    Background Good decision making has been increasingly cited as a core component of good medical care, and shared decision making is one means of achieving high decision quality. If it is to be a standard, good measures and protocols are needed for assessing the quality of decisions. Consistency with patient goals and concerns is one defining characteristic of a good decision. A new method for evaluating decision quality for major surgical decisions was examined, and a methodology for collecting the needed data was developed. Methods For a national probability sample of fee-for-service Medicare beneficiaries who had a coronary artery bypass graft (CABG), a lumpectomy or a mastectomy for breast cancer, or surgery for prostate cancer during the last half of 2008, a mail survey of selected patients was carried out about one year after the procedures. Patients’ goals and concerns, knowledge, key aspects of interactions with clinicians, and feelings about the decisions were assessed. A Decision Dissonance Score was created that measured the extent to which patient ratings of goals ran counter to the treatment received. The construct and predictive validity of the Decision Dissonance Score was then assessed. Results When data were averaged across all four procedures, patients with more knowledge and those who reported more involvement reported significantly lower Decision Dissonance Scores. Patients with lower Decision Dissonance Scores also reported more confidence in their decisions and feeling more positively about how the treatment turned out, and they were more likely to say that they would make the same decision again. Conclusions Surveying discharged surgery patients is a feasible way to evaluate decision making, and Decision Dissonance appears to be a promising approach to validly measuring decision quality. PMID:23516764

  1. Faculty Evaluation: Number One Quality Control in TQM [Total Quality Management].

    ERIC Educational Resources Information Center

    Andrews, Hans A.; And Others

    The current perception of faculty tenure as a guarantee of a job for life can impede the removal of teachers who do not perform up to standards. Such faculty, however, can have an extremely negative effect on overall college quality, and studies have shown that community college faculty do support post-tenure evaluation if it is responsibly…

  2. Fluorescence excitation-emission matrix (EEM) spectroscopy for rapid identification and quality evaluation of cell culture media components.

    PubMed

    Li, Boyan; Ryan, Paul W; Shanahan, Michael; Leister, Kirk J; Ryder, Alan G

    2011-11-01

    The application of fluorescence excitation-emission matrix (EEM) spectroscopy to the quantitative analysis of complex, aqueous solutions of cell culture media components was investigated. These components, yeastolate, phytone, recombinant human insulin, eRDF basal medium, and four different chemically defined (CD) media, are used for the formulation of basal and feed media employed in the production of recombinant proteins using a Chinese Hamster Ovary (CHO) cell based process. The comprehensive analysis (either identification or quality assessment) of these materials using chromatographic methods is time consuming and expensive and is not suitable for high-throughput quality control. The use of EEM in conjunction with multiway chemometric methods provided a rapid, nondestructive analytical method suitable for the screening of large numbers of samples. Here we used multiway robust principal component analysis (MROBPCA) in conjunction with n-way partial least squares discriminant analysis (NPLS-DA) to develop a robust routine for both the identification and quality evaluation of these important cell culture materials. These methods are applicable to a wide range of complex mixtures because they do not rely on any predetermined compositional or property information, thus making them potentially very useful for sample handling, tracking, and quality assessment in biopharmaceutical industries.

  3. A New Tool for Nutrition App Quality Evaluation (AQEL): Development, Validation, and Reliability Testing

    PubMed Central

    Huang, Wenhao; Chapman-Novakofski, Karen M

    2017-01-01

    Background The extensive availability and increasing use of mobile apps for nutrition-based health interventions makes evaluation of the quality of these apps crucial for integration of apps into nutritional counseling. Objective The goal of this research was the development, validation, and reliability testing of the app quality evaluation (AQEL) tool, an instrument for evaluating apps’ educational quality and technical functionality. Methods Items for evaluating app quality were adapted from website evaluations, with additional items added to evaluate the specific characteristics of apps, resulting in 79 initial items. Expert panels of nutrition and technology professionals and app users reviewed items for face and content validation. After recommended revisions, nutrition experts completed a second AQEL review to ensure clarity. On the basis of 150 sets of responses using the revised AQEL, principal component analysis was completed, reducing AQEL into 5 factors that underwent reliability testing, including internal consistency, split-half reliability, test-retest reliability, and interrater reliability (IRR). Two additional modifiable constructs for evaluating apps based on the age and needs of the target audience as selected by the evaluator were also tested for construct reliability. IRR testing using intraclass correlations (ICC) with all 7 constructs was conducted, with 15 dietitians evaluating one app. Results Development and validation resulted in the 51-item AQEL. These were reduced to 25 items in 5 factors after principal component analysis, plus 9 modifiable items in two constructs that were not included in principal component analysis. Internal consistency and split-half reliability of the following constructs derived from principal components analysis was good (Cronbach alpha >.80, Spearman-Brown coefficient >.80): behavior change potential, support of knowledge acquisition, app function, and skill development. App purpose split half-reliability was

  4. Application of Analytical Hierarchy Process Approach for Service Quality Evaluation in Radiology Departments: A Cross-Sectional Study.

    PubMed

    Alimohammadzadeh, Khalil; Bahadori, Mohammadkarim; Hassani, Fariba

    2016-01-01

    Radiology department as a service provider organization requires realization of quality concept concerning service provisioning knowledge, satisfaction and all issues relating to the customer as well as quality assurance and improvement issues. At present, radiology departments in hospitals are regarded as income generating units and they should continuously seek performance improvement so that they can survive in the changing and competitive environment of the health care sector. The aim of this study was to propose a method for ranking of radiology departments in selected hospitals of Tehran city using analytical hierarchical process (AHP) and quality evaluation of their service in 2015. This study was an applied and cross-sectional study, carried out in radiology departments of 6 Tehran educational hospitals in 2015. The hospitals were selected using non-probability and purposeful method. Data gathering was performed using customized joint commission international (JCI) standards. Expert Choice 10.0 software was used for data analysis. AHP method was used for prioritization. "Management and empowerment of human resources'' (weight = 0.465) and "requirements and facilities" (weight = 0.139) were of highest and lowest significance respectively in the overall ranking of the hospitals. MS (weight = 0.316), MD (weight = 0.259), AT (weight = 0.14), TS (weight = 0.108), MO (weight = 0.095), and LH (0.082) achieved the first to sixth rankings respectively. The use of AHP method can be promising for fostering the evaluation method and subsequently promotion of the efficiency and effectiveness of the radiology departments. The present model can fill in the gap in the accreditation system of the country's hospitals in respect with ranking and comparing them considering the significance and value of each individual criteria and standard. Accordingly, it can predict an integration of qualitative and quantitative criteria involved and thereby take a decisive step towards

  5. Imaging quality analysis of computer-generated holograms using the point-based method and slice-based method

    NASA Astrophysics Data System (ADS)

    Zhang, Zhen; Chen, Siqing; Zheng, Huadong; Sun, Tao; Yu, Yingjie; Gao, Hongyue; Asundi, Anand K.

    2017-06-01

    Computer holography has made a notably progress in recent years. The point-based method and slice-based method are chief calculation algorithms for generating holograms in holographic display. Although both two methods are validated numerically and optically, the differences of the imaging quality of these methods have not been specifically analyzed. In this paper, we analyze the imaging quality of computer-generated phase holograms generated by point-based Fresnel zone plates (PB-FZP), point-based Fresnel diffraction algorithm (PB-FDA) and slice-based Fresnel diffraction algorithm (SB-FDA). The calculation formula and hologram generation with three methods are demonstrated. In order to suppress the speckle noise, sequential phase-only holograms are generated in our work. The results of reconstructed images numerically and experimentally are also exhibited. By comparing the imaging quality, the merits and drawbacks with three methods are analyzed. Conclusions are given by us finally.

  6. Service Quality Assessment Scale (SQAS): An Instrument for Evaluating Service Quality of Health-Fitness Clubs

    ERIC Educational Resources Information Center

    Lam, Eddie T. C.; Zhang, James J.; Jensen, Barbara E.

    2005-01-01

    This study was designed to develop the Service Quality Assessment Scale to evaluate the service quality of health-fitness clubs. Through a review of literature, field observations, interviews, modified application of the Delphi technique, and a pilot study, a preliminary scale with 46 items was formulated. The preliminary scale was administered to…

  7. Comparing Two Methods for Reducing Variability in Voice Quality Measurements

    ERIC Educational Resources Information Center

    Kreiman, Jody; Gerratt, Bruce R.

    2011-01-01

    Purpose: Interrater disagreements in ratings of quality plague the study of voice. This study compared 2 methods for handling this variability. Method: Listeners provided multiple breathiness ratings for 2 sets of pathological voices, one including 20 male and 20 female voices unselected for quality and one including 20 breathy female voices.…

  8. Evaluation of sleep quality in subjects with chronic nononcologic pain.

    PubMed

    Covarrubias-Gomez, Alfredo; Mendoza-Reyes, Jonathan J

    2013-08-01

    A survey conducted by the National Sleep Foundation found that 20% of Americans have sleep disorders and 45% experience chronic pain. Several authors evaluated the interrelationship between these functions using various instruments such the Pittsburgh Sleep Quality Index (PSQI) and identified that 34% of subjects in the general population have a poor quality of sleep, but there are few studies that assess the quality of sleep in patients with chronic pain of nonmalignant origin. We undertook this study to evaluate the quality of sleep using the PSQI in patients with chronic pain unrelated to cancer. We conducted a clinical, nonrandomized, uncontrolled, descriptive, and prospective study, applying the PSQI through a direct one-time interview to 311 subjects with chronic pain unrelated to cancer. According to the categorization of the PSQI between good and poor sleepers, 89% of the subjects were poor sleepers (n = 276). There are significant differences in pain intensity according to the categorization of the PSQI, with a higher intensity shown in the "poor sleepers" (analysis of variance [ANOVA], P = .030). Using a linear regression model to estimate the curve, a higher score is rated on the PSQI global score (ANOVA, P = .000, R(2) = .46) with the increase of the intensity of the pain. We conclude that "poor sleepers" or those who considered their sleep as "poor quality" have significantly higher pain intensity. This suggests that intensity of pain plays a role in evaluating the quality of sleep in the subjective perception of sleep and instruments that assess quality.

  9. Multisite Evaluation of a Data Quality Tool for Patient-Level Clinical Data Sets

    PubMed Central

    Huser, Vojtech; DeFalco, Frank J.; Schuemie, Martijn; Ryan, Patrick B.; Shang, Ning; Velez, Mark; Park, Rae Woong; Boyce, Richard D.; Duke, Jon; Khare, Ritu; Utidjian, Levon; Bailey, Charles

    2016-01-01

    Introduction: Data quality and fitness for analysis are crucial if outputs of analyses of electronic health record data or administrative claims data should be trusted by the public and the research community. Methods: We describe a data quality analysis tool (called Achilles Heel) developed by the Observational Health Data Sciences and Informatics Collaborative (OHDSI) and compare outputs from this tool as it was applied to 24 large healthcare datasets across seven different organizations. Results: We highlight 12 data quality rules that identified issues in at least 10 of the 24 datasets and provide a full set of 71 rules identified in at least one dataset. Achilles Heel is a freely available software that provides a useful starter set of data quality rules with the ability to add additional rules. We also present results of a structured email-based interview of all participating sites that collected qualitative comments about the value of Achilles Heel for data quality evaluation. Discussion: Our analysis represents the first comparison of outputs from a data quality tool that implements a fixed (but extensible) set of data quality rules. Thanks to a common data model, we were able to compare quickly multiple datasets originating from several countries in America, Europe and Asia. PMID:28154833

  10. Evaluation Methods Used during the Assessment of an Academic Program at Micro-Level

    ERIC Educational Resources Information Center

    Chinembiri, France

    2017-01-01

    This paper majors on the evaluation criteria and methods used for the assessment of health education programs in the United States. The choice of the topic is dictated by the fact that there is need to improve on the quality of the graduates that the different nursing and medical institutions in the United States produce. By looking at the…

  11. Smartphone Apps for Cardiopulmonary Resuscitation Training and Real Incident Support: A Mixed-Methods Evaluation Study

    PubMed Central

    Felzen, Marc; Rossaint, Rolf; Tabuenca, Bernardo; Specht, Marcus; Skorning, Max

    2014-01-01

    Background No systematic evaluation of smartphone/mobile apps for resuscitation training and real incident support is available to date. To provide medical, usability, and additional quality criteria for the development of apps, we conducted a mixed-methods sequential evaluation combining the perspective of medical experts and end-users. Objective The study aims to assess the quality of current mobile apps for cardiopulmonary resuscitation (CPR) training and real incident support from expert as well as end-user perspective. Methods Two independent medical experts evaluated the medical content of CPR apps from the Google Play store and the Apple App store. The evaluation was based on pre-defined minimum medical content requirements according to current Basic Life Support (BLS) guidelines. In a second phase, non-medical end-users tested usability and appeal of the apps that had at least met the minimum requirements. Usability was assessed with the System Usability Scale (SUS); appeal was measured with the self-developed ReactionDeck toolkit. Results Out of 61 apps, 46 were included in the experts’ evaluation. A consolidated list of 13 apps resulted for the following layperson evaluation. The interrater reliability was substantial (kappa=.61). Layperson end-users (n=14) had a high interrater reliability (intraclass correlation 1 [ICC1]=.83, P<.001, 95% CI 0.75-0.882 and ICC2=.79, P<.001, 95% CI 0.695-0.869). Their evaluation resulted in a list of 5 recommendable apps. Conclusions Although several apps for resuscitation training and real incident support are available, very few are designed according to current BLS guidelines and offer an acceptable level of usability and hedonic quality for laypersons. The results of this study are intended to optimize the development of CPR mobile apps. The app ranking supports the informed selection of mobile apps for training situations and CPR campaigns as well as for real incident support. PMID:24647361

  12. Quality of Instruction Improved by Evaluation and Consultation of Instructors

    ERIC Educational Resources Information Center

    Rindermann, Heiner; Kohler, Jurgen; Meisenberg, Gerhard

    2007-01-01

    One aim of student evaluation of instruction is the improvement of teaching quality, but there is little evidence that student assessment of instruction alone improves teaching. This study tried to improve the effects of evaluation by combining evaluation with individual counselling in an institutional development approach. Evaluation was…

  13. Evaluation Of Water Quality At River Bian In Merauke Papua

    NASA Astrophysics Data System (ADS)

    Djaja, Irba; Purwanto, P.; Sunoko, H. R.

    2018-02-01

    River Bian in Merauke Regency has been utilized by local people in Papua (the Marind) who live along the river for fulfilling their daily needs, such as shower, cloth and dish washing, and even defecation, waste disposal, including domestic waste, as well as for ceremonial activities related to the locally traditional culture. Change in land use for other necessities and domestic activities of the local people have mounted pressures on the status of the River Bian, thus decreasing the quality of the river. This study had objectives to find out and to analyze river water quality and water quality status of the River Bian, and its compliance with water quality standards for ideal use. The study determined sample point by a purposive sampling method, taking the water samples with a grab method. The analysis of the water quality was performed by standard and pollution index methods. The study revealed that the water quality of River Bian, concerning BOD, at the station 3 had exceeded quality threshold. COD parameter for all stations had exceeded the quality threshold for class III. At three stations, there was a decreasing value due to increasing PI, as found at the stations 1, 2, and 3. In other words, River Bian had been lightly contaminated.

  14. Comparative Study in Laboratory Rats to Validate Sperm Quality Methods and Endpoints

    NASA Technical Reports Server (NTRS)

    Price, W. A.; Briggs, G. B.; Alexander, W. K.; Still, K. R.; Grasman, K. A.

    2000-01-01

    Abstract The Naval Health Research Center, Detachment (Toxicology) performs toxicity studies in laboratory animals to characterize the risk of exposure to chemicals of Navy interest. Research was conducted at the Toxicology Detachment at WPAFB, OH in collaboration with Wright State University, Department of Biological Sciences for the validation of new bioassay methods for evaluating reproductive toxicity. The Hamilton Thorne sperm analyzer was used to evaluate sperm damage produced by exposure to a known testicular toxic agent, methoxyacetic acid and by inhalation exposure to JP-8 and JP-5 in laboratory rats. Sperm quality parameters were evaluated (sperm concentration, motility, and morphology) to provide evidence of sperm damage. The Hamilton Thorne sperm analyzer utilizes a DNA specific fluorescent stain (similar to flow cytometry) and digitized optical computer analysis to detect sperm cell damage. The computer assisted sperm analysis (CASA) is a more rapid, robust, predictive and sensitive method for characterizing reproductive toxicity. The results presented in this poster report validation information showing exposure to methoxyacetic acid causes reproductive toxicity and inhalation exposure to JP-8 and JP-5 had no significant effects. The CASA method detects early changes that result in reproductive deficits and these data will be used in a continuing program to characterize the toxicity of chemicals, and combinations of chemicals, of military interest to formulate permissible exposure limits.

  15. A systematic evaluation of normalization methods in quantitative label-free proteomics.

    PubMed

    Välikangas, Tommi; Suomi, Tomi; Elo, Laura L

    2018-01-01

    To date, mass spectrometry (MS) data remain inherently biased as a result of reasons ranging from sample handling to differences caused by the instrumentation. Normalization is the process that aims to account for the bias and make samples more comparable. The selection of a proper normalization method is a pivotal task for the reliability of the downstream analysis and results. Many normalization methods commonly used in proteomics have been adapted from the DNA microarray techniques. Previous studies comparing normalization methods in proteomics have focused mainly on intragroup variation. In this study, several popular and widely used normalization methods representing different strategies in normalization are evaluated using three spike-in and one experimental mouse label-free proteomic data sets. The normalization methods are evaluated in terms of their ability to reduce variation between technical replicates, their effect on differential expression analysis and their effect on the estimation of logarithmic fold changes. Additionally, we examined whether normalizing the whole data globally or in segments for the differential expression analysis has an effect on the performance of the normalization methods. We found that variance stabilization normalization (Vsn) reduced variation the most between technical replicates in all examined data sets. Vsn also performed consistently well in the differential expression analysis. Linear regression normalization and local regression normalization performed also systematically well. Finally, we discuss the choice of a normalization method and some qualities of a suitable normalization method in the light of the results of our evaluation. © The Author 2016. Published by Oxford University Press.

  16. Abstract analysis method facilitates filtering low-methodological quality and high-bias risk systematic reviews on psoriasis interventions.

    PubMed

    Gómez-García, Francisco; Ruano, Juan; Aguilar-Luque, Macarena; Alcalde-Mellado, Patricia; Gay-Mimbrera, Jesús; Hernández-Romero, José Luis; Sanz-Cabanillas, Juan Luis; Maestre-López, Beatriz; González-Padilla, Marcelino; Carmona-Fernández, Pedro J; García-Nieto, Antonio Vélez; Isla-Tejera, Beatriz

    2017-12-29

    Article summaries' information and structure may influence researchers/clinicians' decisions to conduct deeper full-text analyses. Specifically, abstracts of systematic reviews (SRs) and meta-analyses (MA) should provide structured summaries for quick assessment. This study explored a method for determining the methodological quality and bias risk of full-text reviews using abstract information alone. Systematic literature searches for SRs and/or MA about psoriasis were undertaken on MEDLINE, EMBASE, and Cochrane database. For each review, quality, abstract-reporting completeness, full-text methodological quality, and bias risk were evaluated using Preferred Reporting Items for Systematic Reviews and Meta-analyses for abstracts (PRISMA-A), Assessing the Methodological Quality of Systematic Reviews (AMSTAR), and ROBIS tools, respectively. Article-, author-, and journal-derived metadata were systematically extracted from eligible studies using a piloted template, and explanatory variables concerning abstract-reporting quality were assessed using univariate and multivariate-regression models. Two classification models concerning SRs' methodological quality and bias risk were developed based on per-item and total PRISMA-A scores and decision-tree algorithms. This work was supported, in part, by project ICI1400136 (JR). No funding was received from any pharmaceutical company. This study analysed 139 SRs on psoriasis interventions. On average, they featured 56.7% of PRISMA-A items. The mean total PRISMA-A score was significantly higher for high-methodological-quality SRs than for moderate- and low-methodological-quality reviews. SRs with low-bias risk showed higher total PRISMA-A values than reviews with high-bias risk. In the final model, only 'authors per review > 6' (OR: 1.098; 95%CI: 1.012-1.194), 'academic source of funding' (OR: 3.630; 95%CI: 1.788-7.542), and 'PRISMA-endorsed journal' (OR: 4.370; 95%CI: 1.785-10.98) predicted PRISMA-A variability. Reviews with a

  17. Sensory and rapid instrumental methods as a combined tool for quality control of cooked ham.

    PubMed

    Barbieri, Sara; Soglia, Francesca; Palagano, Rosa; Tesini, Federica; Bendini, Alessandra; Petracci, Massimiliano; Cavani, Claudio; Gallina Toschi, Tullia

    2016-11-01

    In this preliminary investigation, different commercial categories of Italian cooked pork hams have been characterized using an integrated approach based on both sensory and fast instrumental measurements. For these purposes, Italian products belonging to different categories (cooked ham, "selected" cooked ham and "high quality" cooked ham) were evaluated by sensory descriptive analysis and by the application of rapid tools such as image analysis by an "electronic eye" and texture analyzer. The panel of trained assessors identified and evaluated 10 sensory descriptors able to define the quality of the products. Statistical analysis highlighted that sensory characteristics related to appearance and texture were the most significant in discriminating samples belonged to the highest (high quality cooked hams) and the lowest (cooked hams) quality of the product whereas the selected cooked hams, showed intermediate characteristics. In particular, high quality samples were characterized, above all, by the highest intensity of pink intensity, typical appearance and cohesiveness, and, at the same time, by the lowest intensity of juiciness; standard cooked ham samples showed the lowest intensity of all visual attributes and the highest value of juiciness, whereas the intermediate category (selected cooked ham) was not discriminated from the other. Also physical-rheological parameters measured by electronic eye and texture analyzer were effective in classifying samples. In particular, the PLS model built with data obtained from the electronic eye showed a satisfactory performance in terms of prediction of the pink intensity and presence of fat attributes evaluated during the sensory visual phase. This study can be considered a first application of this combined approach that could represent a suitable and fast method to verify if the meat product purchased by consumer match its description in terms of compliance with the claimed quality.

  18. EAPhy: A Flexible Tool for High-throughput Quality Filtering of Exon-alignments and Data Processing for Phylogenetic Methods.

    PubMed

    Blom, Mozes P K

    2015-08-05

    Recently developed molecular methods enable geneticists to target and sequence thousands of orthologous loci and infer evolutionary relationships across the tree of life. Large numbers of genetic markers benefit species tree inference but visual inspection of alignment quality, as traditionally conducted, is challenging with thousands of loci. Furthermore, due to the impracticality of repeated visual inspection with alternative filtering criteria, the potential consequences of using datasets with different degrees of missing data remain nominally explored in most empirical phylogenomic studies. In this short communication, I describe a flexible high-throughput pipeline designed to assess alignment quality and filter exonic sequence data for subsequent inference. The stringency criteria for alignment quality and missing data can be adapted based on the expected level of sequence divergence. Each alignment is automatically evaluated based on the stringency criteria specified, significantly reducing the number of alignments that require visual inspection. By developing a rapid method for alignment filtering and quality assessment, the consistency of phylogenetic estimation based on exonic sequence alignments can be further explored across distinct inference methods, while accounting for different degrees of missing data.

  19. Selection indices for quality evaluation in wheat breeding.

    PubMed

    Branlard, G; Pierre, J; Rousset, M

    1992-06-01

    From multilocation trials involving 125 cultivars of wheat of mainly French and European origin four tests - protein content, Pelshenke, modified Zeleny and the mixograph - were used to establish six selection indices. Three of these indices - IW1, IW2 and IW3 - were calculated in order to evaluate the genetic potentiality of the lines for dough strength as given by the Chopin alveograph. The indices IV1, IV2 and IV3 were established to evaluate loaf volume as measured by the French bread-making standard. A quality index IQ was calculated from the allelic effects of the high-molecular-weight (HMW) subunits of glutenin from 195 cultivars assessed by the Chopin alveograph and the Pelshenke test. Comparison of the relative efficiency of each of the six indices to the individual tests revealed the superiority of the indices over one or several technological parameters. The six selection indices and the quality index were compared using 30 very diverse F4 lines. Their ability to retain the good quality lines is discussed in particular.

  20. Economic evaluation in collaborative hospital drug evaluation reports.

    PubMed

    Ortega, Ana; Fraga, María Dolores; Marín-Gil, Roberto; Lopez-Briz, Eduardo; Puigventós, Francesc; Dranitsaris, George

    2015-09-01

    economic evaluation is a fundamental criterion when deciding a drug's place in therapy. The MADRE method (Method for Assistance in making Decisions and Writing Drug Evaluation Reports) is widely used for drug evaluation. This method was developed by the GENESIS group of the Spanish Society of Hospital Pharmacy (SEFH), including economic evaluation. We intend to improve the economic aspects of this method. As for the direction to take, we have to first analyze our previous experiences with the current methodology and propose necessary improvements. economic evaluation sections in collaboratively conducted drug evaluation reports (as the scientific society, SEFH) with the MADRE method were reviewed retrospectively. thirty-two reports were reviewed, 87.5% of them included an economic evaluation conducted by authors and 65.6% contained published economic evaluations. In 90.6% of the reports, a Budget impact analysis was conducted. The cost per life year gained or per Quality Adjusted Life Year gained was present in 14 reports. Twenty-three reports received public comments regarding the need to improve the economic aspect. Main difficulties: low quality evidence in the target population, no comparative studies with a relevant comparator, non-final outcomes evaluated, no quality of life data, no fixed drug price available, dosing uncertainty, and different prices for the same drug. proposed improvements: incorporating different forms of aid for non-drug costs, survival estimation and adapting published economic evaluations; establishing criteria for drug price selection, decision-making in conditions of uncertainty and poor quality evidence, dose calculation and cost-effectiveness thresholds depending on different situations. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  1. Effects of alternative silvicultural methods on scenic and recreational quality

    Treesearch

    Mark Brunson; Bo Shelby

    1992-01-01

    Timber stands harvested using different silvicultural regimes were evaluated for acceptability as places for hiking, camping, and scenic viewing. "New Forestry" stands were more acceptable than stands managed using traditional practices. Stands were rated differently for different uses, with camping quality judged lower than hiking or scenic quality.

  2. Modelling and control for laser based welding processes: modern methods of process control to improve quality of laser-based joining methods

    NASA Astrophysics Data System (ADS)

    Zäh, Ralf-Kilian; Mosbach, Benedikt; Hollwich, Jan; Faupel, Benedikt

    2017-02-01

    To ensure the competitiveness of manufacturing companies it is indispensable to optimize their manufacturing processes. Slight variations of process parameters and machine settings have only marginally effects on the product quality. Therefore, the largest possible editing window is required. Such parameters are, for example, the movement of the laser beam across the component for the laser keyhole welding. That`s why it is necessary to keep the formation of welding seams within specified limits. Therefore, the quality of laser welding processes is ensured, by using post-process methods, like ultrasonic inspection, or special in-process methods. These in-process systems only achieve a simple evaluation which shows whether the weld seam is acceptable or not. Furthermore, in-process systems use no feedback for changing the control variables such as speed of the laser or adjustment of laser power. In this paper the research group presents current results of the research field of Online Monitoring, Online Controlling and Model predictive controlling in laser welding processes to increase the product quality. To record the characteristics of the welding process, tested online methods are used during the process. Based on the measurement data, a state space model is ascertained, which includes all the control variables of the system. Depending on simulation tools the model predictive controller (MPC) is designed for the model and integrated into an NI-Real-Time-System.

  3. An evaluation method for nanoscale wrinkle

    NASA Astrophysics Data System (ADS)

    Liu, Y. P.; Wang, C. G.; Zhang, L. M.; Tan, H. F.

    2016-06-01

    In this paper, a spectrum-based wrinkling analysis method via two-dimensional Fourier transformation is proposed aiming to solve the difficulty of nanoscale wrinkle evaluation. It evaluates the wrinkle characteristics including wrinkling wavelength and direction simply using a single wrinkling image. Based on this method, the evaluation results of nanoscale wrinkle characteristics show agreement with the open experimental results within an error of 6%. It is also verified to be appropriate for the macro wrinkle evaluation without scale limitations. The spectrum-based wrinkling analysis is an effective method for nanoscale evaluation, which contributes to reveal the mechanism of nanoscale wrinkling.

  4. Evaluating the appropriateness of antimicrobial treatment in hospitalized patients: a comparison of three methods.

    PubMed

    Reisfeld, S; Assaly, M; Tannous, E; Amarney, K; Stein, M

    2018-06-01

    Approximately 20-50% of antimicrobial therapy in hospitalized patients is considered inappropriate, which may be associated with increased morbidity and mortality. The best method for evaluation of appropriateness is not well defined. To evaluate the rate of appropriate antimicrobial therapy in a secondary hospital using three different methods, and determine the rate of agreement between the different methods. A point prevalence study included all adult hospitalized patients receiving systemic antimicrobial therapy during 2016, screened on a single day. Clinical, laboratory and therapeutic data were collected from patient files, and appropriateness was rated with a qualitative evaluation by expert opinion. In addition, a quantitative evaluation was performed according to 11 quality indicators (QIs) rated for each patient. A strict definition of appropriateness was fulfilled if six essential QIs were met, and a lenient definition was fulfilled if at least five QIs were met. Agreement between methods was analysed using kappa statistic. Among 106 patients included, rates of appropriateness of antimicrobial therapy ranged from 20% to 75%, depending on the method of evaluation. Very low agreement was found between the strict definition and expert opinion (kappa=0.068), and medium agreement was found between the lenient definition and expert opinion (kappa=0.45). Rates of appropriateness of antimicrobial therapy varied between evaluation methods, with low to moderate agreement between the different methods. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  5. HIV quality report cards: impact of case-mix adjustment and statistical methods.

    PubMed

    Ohl, Michael E; Richardson, Kelly K; Goto, Michihiko; Vaughan-Sarrazin, Mary; Schweizer, Marin L; Perencevich, Eli N

    2014-10-15

    There will be increasing pressure to publicly report and rank the performance of healthcare systems on human immunodeficiency virus (HIV) quality measures. To inform discussion of public reporting, we evaluated the influence of case-mix adjustment when ranking individual care systems on the viral control quality measure. We used data from the Veterans Health Administration (VHA) HIV Clinical Case Registry and administrative databases to estimate case-mix adjusted viral control for 91 local systems caring for 12 368 patients. We compared results using 2 adjustment methods, the observed-to-expected estimator and the risk-standardized ratio. Overall, 10 913 patients (88.2%) achieved viral control (viral load ≤400 copies/mL). Prior to case-mix adjustment, system-level viral control ranged from 51% to 100%. Seventeen (19%) systems were labeled as low outliers (performance significantly below the overall mean) and 11 (12%) as high outliers. Adjustment for case mix (patient demographics, comorbidity, CD4 nadir, time on therapy, and income from VHA administrative databases) reduced the number of low outliers by approximately one-third, but results differed by method. The adjustment model had moderate discrimination (c statistic = 0.66), suggesting potential for unadjusted risk when using administrative data to measure case mix. Case-mix adjustment affects rankings of care systems on the viral control quality measure. Given the sensitivity of rankings to selection of case-mix adjustment methods-and potential for unadjusted risk when using variables limited to current administrative databases-the HIV care community should explore optimal methods for case-mix adjustment before moving forward with public reporting. Published by Oxford University Press on behalf of the Infectious Diseases Society of America 2014. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  6. Quality evaluation of value sets from cancer study common data elements using the UMLS semantic groups

    PubMed Central

    Solbrig, Harold R; Chute, Christopher G

    2012-01-01

    Objective The objective of this study is to develop an approach to evaluate the quality of terminological annotations on the value set (ie, enumerated value domain) components of the common data elements (CDEs) in the context of clinical research using both unified medical language system (UMLS) semantic types and groups. Materials and methods The CDEs of the National Cancer Institute (NCI) Cancer Data Standards Repository, the NCI Thesaurus (NCIt) concepts and the UMLS semantic network were integrated using a semantic web-based framework for a SPARQL-enabled evaluation. First, the set of CDE-permissible values with corresponding meanings in external controlled terminologies were isolated. The corresponding value meanings were then evaluated against their NCI- or UMLS-generated semantic network mapping to determine whether all of the meanings fell within the same semantic group. Results Of the enumerated CDEs in the Cancer Data Standards Repository, 3093 (26.2%) had elements drawn from more than one UMLS semantic group. A random sample (n=100) of this set of elements indicated that 17% of them were likely to have been misclassified. Discussion The use of existing semantic web tools can support a high-throughput mechanism for evaluating the quality of large CDE collections. This study demonstrates that the involvement of multiple semantic groups in an enumerated value domain of a CDE is an effective anchor to trigger an auditing point for quality evaluation activities. Conclusion This approach produces a useful quality assurance mechanism for a clinical study CDE repository. PMID:22511016

  7. Validation of a combi oven cooking method for preparation of chicken breast meat for quality assessment.

    PubMed

    Zhuang, H; Savage, E M

    2008-10-01

    Quality assessment results of cooked meat can be significantly affected by sample preparation with different cooking techniques. A combi oven is a relatively new cooking technique in the U.S. market. However, there was a lack of published data about its effect on quality measurements of chicken meat. Broiler breast fillets deboned at 24-h postmortem were cooked with one of the 3 methods to the core temperature of 80 degrees C. Cooking methods were evaluated based on cooking operation requirements, sensory profiles, Warner-Bratzler (WB) shear and cooking loss. Our results show that the average cooking time for the combi oven was 17 min compared with 31 min for the commercial oven method and 16 min for the hot water method. The combi oven did not result in a significant difference in the WB shear force values, although the cooking loss of the combi oven samples was significantly lower than the commercial oven and hot water samples. Sensory profiles of the combi oven samples did not significantly differ from those of the commercial oven and hot water samples. These results demonstrate that combi oven cooking did not significantly affect sensory profiles and WB shear force measurements of chicken breast muscle compared to the other 2 cooking methods. The combi oven method appears to be an acceptable alternative for preparing chicken breast fillets in a quality assessment.

  8. [Evaluation of reporting quality of RCT on nephrotoxicity of Tripterygium wilfordii preparations according to CONSORT HARMs statement].

    PubMed

    Feng, Xue; Fang, Sai-Nan; Gao, Yu-Xin; Liu, Jian-Ping; Chen, Wei

    2018-02-01

    To evaluate the quality of randomized controlled trials(RCT) on nephrotoxicity of Tripterygium wilfordii preparations according to the CONSORT HARMs statement. The report quality of each included study was evaluated according to the CONSORT HARMs statement, and the number of entries that comply with CONSORT HARMs statement was calculated in each study to evaluate the report quality on nephrotoxicity-related adverse reactions of T. wilfordii preparations and summarize the problems in domestic studies on nephrotoxicity-related adverse reactions. A total of 16 RCTs were included, with an average of 7 entries complying with CONSORT HARMs statement per study. The report of the nephrotoxic-associated RCT of T. wilfordii preparations was of poor quality and the most non-repeating entries included the following ones: using validated tools to report adverse effects, standards for coding of the adverse reactions, describing how and when to collect data on adverse reactions in Method, describing how adverse reactions are attributed to T. wilfordii, clearly stating who has reported the adverse reactions, describing the analysis method of adverse reactions, describing the method of collecting recurrent adverse reaction data, describing any subgroup analysis and exploratory analysis associated with the hazard. We suggest that the studies on adverse reactions of traditional Chinese medicine should strictly report the entries according to the CONSORT HARMs statement, and take the characteristics of traditional Chinese medicine into account to report the details of the Chinese medicine like compositions, dose, taking time, combined medication and the dialectical typology of research objects. Copyright© by the Chinese Pharmaceutical Association.

  9. Development of evaluation technique of GMAW welding quality based on statistical analysis

    NASA Astrophysics Data System (ADS)

    Feng, Shengqiang; Terasaki, Hidenri; Komizo, Yuichi; Hu, Shengsun; Chen, Donggao; Ma, Zhihua

    2014-11-01

    Nondestructive techniques for appraising gas metal arc welding(GMAW) faults plays a very important role in on-line quality controllability and prediction of the GMAW process. On-line welding quality controllability and prediction have several disadvantages such as high cost, low efficiency, complication and greatly being affected by the environment. An enhanced, efficient evaluation technique for evaluating welding faults based on Mahalanobis distance(MD) and normal distribution is presented. In addition, a new piece of equipment, designated the weld quality tester(WQT), is developed based on the proposed evaluation technique. MD is superior to other multidimensional distances such as Euclidean distance because the covariance matrix used for calculating MD takes into account correlations in the data and scaling. The values of MD obtained from welding current and arc voltage are assumed to follow a normal distribution. The normal distribution has two parameters: the mean µ and standard deviation σ of the data. In the proposed evaluation technique used by the WQT, values of MD located in the range from zero to µ+3 σ are regarded as "good". Two experiments which involve changing the flow of shielding gas and smearing paint on the surface of the substrate are conducted in order to verify the sensitivity of the proposed evaluation technique and the feasibility of using WQT. The experimental results demonstrate the usefulness of the WQT for evaluating welding quality. The proposed technique can be applied to implement the on-line welding quality controllability and prediction, which is of great importance to design some novel equipment for weld quality detection.

  10. A framework for assessing Health Economic Evaluation (HEE) quality appraisal instruments.

    PubMed

    Langer, Astrid

    2012-08-16

    Health economic evaluations support the health care decision-making process by providing information on costs and consequences of health interventions. The quality of such studies is assessed by health economic evaluation (HEE) quality appraisal instruments. At present, there is no instrument for measuring and improving the quality of such HEE quality appraisal instruments. Therefore, the objectives of this study are to establish a framework for assessing the quality of HEE quality appraisal instruments to support and improve their quality, and to apply this framework to those HEE quality appraisal instruments which have been subject to more scrutiny than others, in order to test the framework and to demonstrate the shortcomings of existing HEE quality appraisal instruments. To develop the quality assessment framework for HEE quality appraisal instruments, the experiences of using appraisal tools for clinical guidelines are used. Based on a deductive iterative process, clinical guideline appraisal instruments identified through literature search are reviewed, consolidated, and adapted to produce the final quality assessment framework for HEE quality appraisal instruments. The final quality assessment framework for HEE quality appraisal instruments consists of 36 items organized within 7 dimensions, each of which captures a specific domain of quality. Applying the quality assessment framework to four existing HEE quality appraisal instruments, it is found that these four quality appraisal instruments are of variable quality. The framework described in this study should be regarded as a starting point for appraising the quality of HEE quality appraisal instruments. This framework can be used by HEE quality appraisal instrument producers to support and improve the quality and acceptance of existing and future HEE quality appraisal instruments. By applying this framework, users of HEE quality appraisal instruments can become aware of methodological deficiencies

  11. Nondestructive tests of regenerative chambers. [evaluating nondestructive methods of determining metal bond integrity

    NASA Technical Reports Server (NTRS)

    Malone, G. A.; Vecchies, L.; Wood, R.

    1974-01-01

    The capabilities and limitations of nondestructive evaluation methods were studied to detect and locate bond deficiencies in regeneratively cooled thrust chambers for rocket engines. Flat test panels and a cylinder were produced to simulate regeneratively cooled thrust chamber walls. Planned defects with various bond integrities were produced in the panels to evaluate the sensitivity, accuracy, and limitations of nondestructive methods to define and locate bond anomalies. Holography, acoustic emission, and ultrasonic scan were found to yield sufficient data to discern bond quality when used in combination and in selected sequences. Bonding techniques included electroforming and brazing. Materials of construction included electroformed nickel bonded to Nickel 200 and OFHC copper, electroformed copper bonded to OFHC copper, and 300 series stainless steel brazed to OFHC copper. Variations in outer wall strength, wall thickness, and defect size were evaluated for nondestructive test response.

  12. Gaussian beam profile shaping apparatus, method therefor and evaluation thereof

    DOEpatents

    Dickey, Fred M.; Holswade, Scott C.; Romero, Louis A.

    1999-01-01

    A method and apparatus maps a Gaussian beam into a beam with a uniform irradiance profile by exploiting the Fourier transform properties of lenses. A phase element imparts a design phase onto an input beam and the output optical field from a lens is then the Fourier transform of the input beam and the phase function from the phase element. The phase element is selected in accordance with a dimensionless parameter which is dependent upon the radius of the incoming beam, the desired spot shape, the focal length of the lens and the wavelength of the input beam. This dimensionless parameter can also be used to evaluate the quality of a system. In order to control the radius of the incoming beam, optics such as a telescope can be employed. The size of the target spot and the focal length can be altered by exchanging the transform lens, but the dimensionless parameter will remain the same. The quality of the system, and hence the value of the dimensionless parameter, can be altered by exchanging the phase element. The dimensionless parameter provides design guidance, system evaluation, and indication as to how to improve a given system.

  13. Gaussian beam profile shaping apparatus, method therefore and evaluation thereof

    DOEpatents

    Dickey, F.M.; Holswade, S.C.; Romero, L.A.

    1999-01-26

    A method and apparatus maps a Gaussian beam into a beam with a uniform irradiance profile by exploiting the Fourier transform properties of lenses. A phase element imparts a design phase onto an input beam and the output optical field from a lens is then the Fourier transform of the input beam and the phase function from the phase element. The phase element is selected in accordance with a dimensionless parameter which is dependent upon the radius of the incoming beam, the desired spot shape, the focal length of the lens and the wavelength of the input beam. This dimensionless parameter can also be used to evaluate the quality of a system. In order to control the radius of the incoming beam, optics such as a telescope can be employed. The size of the target spot and the focal length can be altered by exchanging the transform lens, but the dimensionless parameter will remain the same. The quality of the system, and hence the value of the dimensionless parameter, can be altered by exchanging the phase element. The dimensionless parameter provides design guidance, system evaluation, and indication as to how to improve a given system. 27 figs.

  14. Large radius of curvature measurement based on the evaluation of interferogram-quality metric in non-null interferometry

    NASA Astrophysics Data System (ADS)

    Yang, Zhongming; Dou, Jiantai; Du, Jinyu; Gao, Zhishan

    2018-03-01

    Non-null interferometry could use to measure the radius of curvature (ROC), we have presented a virtual quadratic Newton rings phase-shifting moiré-fringes measurement method for large ROC measurement (Yang et al., 2016). In this paper, we propose a large ROC measurement method based on the evaluation of the interferogram-quality metric by the non-null interferometer. With the multi-configuration model of the non-null interferometric system in ZEMAX, the retrace errors and the phase introduced by the test surface are reconstructed. The interferogram-quality metric is obtained by the normalized phase-shifted testing Newton rings with the spherical surface model in the non-null interferometric system. The radius curvature of the test spherical surface can be obtained until the minimum of the interferogram-quality metric is found. Simulations and experimental results are verified the feasibility of our proposed method. For a spherical mirror with a ROC of 41,400 mm, the measurement accuracy is better than 0.13%.

  15. [Optimal scan parameters for a method of k-space trajectory (radial scan method) in evaluation of carotid plaque characteristics].

    PubMed

    Nakamura, Manami; Makabe, Takeshi; Tezuka, Hideomi; Miura, Takahiro; Umemura, Takuma; Sugimori, Hiroyuki; Sakata, Motomichi

    2013-04-01

    The purpose of this study was to optimize scan parameters for evaluation of carotid plaque characteristics by k-space trajectory (radial scan method), using a custom-made carotid plaque phantom. The phantom was composed of simulated sternocleidomastoid muscle and four types of carotid plaque. The effect of chemical shift artifact was compared using T1 weighted images (T1WI) of the phantom obtained with and without fat suppression, and using two types of k-space trajectory (the radial scan method and the Cartesian method). The ratio of signal intensity of simulated sternocleidomastoid muscle to the signal intensity of hematoma, blood (including heparin), lard, and mayonnaise was compared among various repetition times (TR) using T1WI and T2 weighted imaging (T2WI). In terms of chemical shift artifacts, image quality was improved using fat suppression for both the radial scan and Cartesian methods. In terms of signal ratio, the highest values were obtained for the radial scan method with TR of 500 ms for T1WI, and TR of 3000 ms for T2WI. For evaluation of carotid plaque characteristics using the radial scan method, chemical shift artifacts were reduced with fat suppression. Signal ratio was improved by optimizing the TR settings for T1WI and T2WI. These results suggest the potential for using magnetic resonance imaging for detailed evaluation of carotid plaque.

  16. Development of an environmental chamber for evaluating the performance of low-cost air quality sensors under controlled conditions

    NASA Astrophysics Data System (ADS)

    Papapostolou, Vasileios; Zhang, Hang; Feenstra, Brandon J.; Polidori, Andrea

    2017-12-01

    A state-of-the-art integrated chamber system has been developed for evaluating the performance of low-cost air quality sensors. The system contains two professional grade chamber enclosures. A 1.3 m3 stainless-steel outer chamber and a 0.11 m3 Teflon-coated stainless-steel inner chamber are used to create controlled aerosol and gaseous atmospheres, respectively. Both chambers are temperature and relative humidity controlled with capability to generate a wide range of environmental conditions. The system is equipped with an integrated zero-air system, an ozone and two aerosol generation systems, a dynamic dilution calibrator, certified gas cylinders, an array of Federal Reference Method (FRM), Federal Equivalent Method (FEM), and Best Available Technology (BAT) reference instruments and an automated control and sequencing software. Our experiments have demonstrated that the chamber system is capable of generating stable and reproducible aerosol and gas concentrations at low, medium, and high levels. This paper discusses the development of the chamber system along with the methods used to quantitatively evaluate sensor performance. Considering that a significant number of academic and research institutions, government agencies, public and private institutions, and individuals are becoming interested in developing and using low-cost air quality sensors, it is important to standardize the procedures used to evaluate their performance. The information discussed herein provides a roadmap for entities who are interested in characterizing air quality sensors in a rigorous, systematic and reproducible manner.

  17. Evaluating sustainable water quality management in the U.S.: Urban, Agricultural, and Environmental Protection Practices

    NASA Astrophysics Data System (ADS)

    van Oel, P. R.; Alfredo, K. A.; Russo, T. A.

    2015-12-01

    Sustainable water management typically emphasizes water resource quantity, with focus directed at availability and use practices. When attention is placed on sustainable water quality management, the holistic, cross-sector perspective inherent to sustainability is often lost. Proper water quality management is a critical component of sustainable development practices. However, sustainable development definitions and metrics related to water quality resilience and management are often not well defined; water quality is often buried in large indicator sets used for analysis, and the policy regulating management practices create sector specific burdens for ensuring adequate water quality. In this research, we investigated the methods by which water quality is evaluated through internationally applied indicators and incorporated into the larger idea of "sustainability." We also dissect policy's role in the distribution of responsibility with regard to water quality management in the United States through evaluation of three broad sectors: urban, agriculture, and environmental water quality. Our research concludes that despite a growing intention to use a single system approach for urban, agricultural, and environmental water quality management, one does not yet exist and is even hindered by our current policies and regulations. As policy continues to lead in determining water quality and defining contamination limits, new regulation must reconcile the disparity in requirements for the contaminators and those performing end-of-pipe treatment. Just as the sustainable development indicators we researched tried to integrate environmental, economic, and social aspects without skewing focus to one of these three categories, policy cannot continue to regulate a single sector of society without considering impacts to the entire watershed and/or region. Unequal distribution of the water pollution burden creates disjointed economic growth, infrastructure development, and policy

  18. User Experience Evaluation Methods in Product Development (UXEM'09)

    NASA Astrophysics Data System (ADS)

    Roto, Virpi; Väänänen-Vainio-Mattila, Kaisa; Law, Effie; Vermeeren, Arnold

    High quality user experience (UX) has become a central competitive factor of product development in mature consumer markets [1]. Although the term UX originated from industry and is a widely used term also in academia, the tools for managing UX in product development are still inadequate. A prerequisite for designing delightful UX in an industrial setting is to understand both the requirements tied to the pragmatic level of functionality and interaction and the requirements pertaining to the hedonic level of personal human needs, which motivate product use [2]. Understanding these requirements helps managers set UX targets for product development. The next phase in a good user-centered design process is to iteratively design and evaluate prototypes [3]. Evaluation is critical for systematically improving UX. In many approaches to UX, evaluation basically needs to be postponed until the product is fully or at least almost fully functional. However, in an industrial setting, it is very expensive to find the UX failures only at this phase of product development. Thus, product development managers and developers have a strong need to conduct UX evaluation as early as possible, well before all the parts affecting the holistic experience are available. Different types of products require evaluation on different granularity and maturity levels of a prototype. For example, due to its multi-user characteristic, a community service or an enterprise resource planning system requires a broader scope of UX evaluation than a microwave oven or a word processor that is meant for a single user at a time. Before systematic UX evaluation can be taken into practice, practical, lightweight UX evaluation methods suitable for different types of products and different phases of product readiness are needed. A considerable amount of UX research is still about the conceptual frameworks and models for user experience [4]. Besides, applying existing usability evaluation methods (UEMs) without

  19. Objectification of perceptual image quality for mobile video

    NASA Astrophysics Data System (ADS)

    Lee, Seon-Oh; Sim, Dong-Gyu

    2011-06-01

    This paper presents an objective video quality evaluation method for quantifying the subjective quality of digital mobile video. The proposed method aims to objectify the subjective quality by extracting edgeness and blockiness parameters. To evaluate the performance of the proposed algorithms, we carried out subjective video quality tests with the double-stimulus continuous quality scale method and obtained differential mean opinion score values for 120 mobile video clips. We then compared the performance of the proposed methods with that of existing methods in terms of the differential mean opinion score with 120 mobile video clips. Experimental results showed that the proposed methods were approximately 10% better than the edge peak signal-to-noise ratio of the J.247 method in terms of the Pearson correlation.

  20. Current progress on GSN data quality evaluation

    NASA Astrophysics Data System (ADS)

    Davis, J. P.; Gee, L. S.; Anderson, K. R.; Ahern, T. K.

    2012-12-01

    We discuss ongoing work to assess and improve the quality of data collected from instruments deployed at the 150+ stations of the Global Seismographic Network (GSN). The USGS and the IRIS Consortium are coordinating efforts to emphasize data quality following completion of the major installation phase of the GSN and recapitalization of the network's data acquisition systems, ancillary equipment and many of the secondary seismic sensors. We highlight here procedures adopted by the network's operators, the USGS' Albuquerque Seismological Laboratory (ASL) and UCSD's Project IDA, to ensure that the quality of the waveforms collected is maximized, that published metadata accurately reflect the instrument response of the data acquisitions systems, and that the data users are informed of the status of the GSN data quality. Additional details can be found at the GSN Quality webpage (www.iris.edu/hq/programs/gsn/quality). The GSN network operation teams meet frequently to share information and techniques. While custom software developed by each network operator to identify and track known problems remains important, recent efforts are providing new resources and tools to evaluate waveform quality, including analysis provided by the Lamont Waveform Quality Center (www.ldeo.columbia.edu/~ekstrom/Projects/WQC.html) and synthetic seismograms made available through Princeton University's Near Real Time Global Seismicity Portal ( http://global.shakemovie.princeton.edu/home.jsp ) and developments such as the IRIS DMS's MUSTANG and the ASL's Data Quality Analyzer. We conclude with the concept of station certification, a comprehensive overview of a station's performance that we have developed to communicate to data users the state of data- and metadata quality. As progress is made to verify the response and performance of existing systems as well as analysis of past calibration signals and waveform data, we will update information on the GSN web portals to apprise users of the

  1. Effect of thawing methods on frozen semen quality of yak (Poephagus grunniens L.) bulls

    PubMed Central

    Borah, Binod Kumar Dutta; Deka, Bharat Chandra; Biswas, Ranjan Kumar; Chakravarty, Prithiviraj; Deori, Sourabh; Sinha, Sudip; Ahmed, Kutubuddin

    2015-01-01

    Aim: To evaluate different thawing temperatures and duration on the post-thaw semen quality of Indian yaks bulls. Materials and Methods: Semen ejaculates from four different yak bulls were collected using artificial vagina method and extended with tris extender containing 6.4% glycerol at 35°C, cooled gradually from 35°C to 5°C at 1°C/3 min and equilibrated at 4-5°C for 4 h and frozen in French mini straws using a programmable bio-freezer and finally stored in liquid nitrogen. Thawing of frozen semen straws was carried out using three methods i.e., 35°C for 60 s (thawing method I), 37°C for 30 s (thawing method II) and 75°C for 9 s (thawing method III). The post-thaw semen quality parameters assessed were sperm motility, percent live sperm, hypo-osmotic swelling test (HOST)-reacted sperm, acrosomal changes, and alanine aminotransferase (ALT) and aspartate aminotransferase (AST) activities in the extracellular media. Results: The percent sperm motility, total incidence of acrosomal changes, and extracellular release of AST varied significantly (p<0.01) between thawing methods but live sperm and HOST-reacted sperm did not vary significantly between thawing methods. The percent sperm motility of frozen yak semen for thawing method III was significantly (p<0.05) higher than that for thawing methods I and II, the difference between thawing methods I and II being non-significant. The critical difference test revealed that the total incidence of acrosomal changes and extracellular release of AST were significantly (p<0.05) lower when thawing was done using methods I and II than in method III. Conclusion: On the basis of the present experiment, we can conclude that barring the post-thaw sperm motility, thawing of frozen yak semen in water either at 35°C for 60 s or 37°C for 30 s gives better post-thaw semen quality than at 75°C for 09 s. PMID:27047161

  2. No-Reference Image Quality Assessment by Wide-Perceptual-Domain Scorer Ensemble Method.

    PubMed

    Liu, Tsung-Jung; Liu, Kuan-Hsien

    2018-03-01

    A no-reference (NR) learning-based approach to assess image quality is presented in this paper. The devised features are extracted from wide perceptual domains, including brightness, contrast, color, distortion, and texture. These features are used to train a model (scorer) which can predict scores. The scorer selection algorithms are utilized to help simplify the proposed system. In the final stage, the ensemble method is used to combine the prediction results from selected scorers. Two multiple-scale versions of the proposed approach are also presented along with the single-scale one. They turn out to have better performances than the original single-scale method. Because of having features from five different domains at multiple image scales and using the outputs (scores) from selected score prediction models as features for multi-scale or cross-scale fusion (i.e., ensemble), the proposed NR image quality assessment models are robust with respect to more than 24 image distortion types. They also can be used on the evaluation of images with authentic distortions. The extensive experiments on three well-known and representative databases confirm the performance robustness of our proposed model.

  3. Application of Analytical Hierarchy Process Approach for Service Quality Evaluation in Radiology Departments: A Cross-Sectional Study

    PubMed Central

    Alimohammadzadeh, Khalil; Bahadori, Mohammadkarim; Hassani, Fariba

    2016-01-01

    Background: Radiology department as a service provider organization requires realization of quality concept concerning service provisioning knowledge, satisfaction and all issues relating to the customer as well as quality assurance and improvement issues. At present, radiology departments in hospitals are regarded as income generating units and they should continuously seek performance improvement so that they can survive in the changing and competitive environment of the health care sector. Objectives: The aim of this study was to propose a method for ranking of radiology departments in selected hospitals of Tehran city using analytical hierarchical process (AHP) and quality evaluation of their service in 2015. Materials and Methods: This study was an applied and cross-sectional study, carried out in radiology departments of 6 Tehran educational hospitals in 2015. The hospitals were selected using non-probability and purposeful method. Data gathering was performed using customized joint commission international (JCI) standards. Expert Choice 10.0 software was used for data analysis. AHP method was used for prioritization. Results: “Management and empowerment of human resources’’ (weight = 0.465) and “requirements and facilities” (weight = 0.139) were of highest and lowest significance respectively in the overall ranking of the hospitals. MS (weight = 0.316), MD (weight = 0.259), AT (weight = 0.14), TS (weight = 0.108), MO (weight = 0.095), and LH (0.082) achieved the first to sixth rankings respectively. Conclusion: The use of AHP method can be promising for fostering the evaluation method and subsequently promotion of the efficiency and effectiveness of the radiology departments. The present model can fill in the gap in the accreditation system of the country’s hospitals in respect with ranking and comparing them considering the significance and value of each individual criteria and standard. Accordingly, it can predict an integration of qualitative

  4. Product Quality Research Institute evaluation of cascade impactor profiles of pharmaceutical aerosols: part 2--evaluation of a method for determining equivalence.

    PubMed

    Christopher, David; Adams, Wallace P; Lee, Douglas S; Morgan, Beth; Pan, Ziqing; Singh, Gur Jai Pal; Tsong, Yi; Lyapustina, Svetlana

    2007-01-19

    The purpose of this article is to present the thought process, methods, and interim results of a PQRI Working Group, which was charged with evaluating the chi-square ratio test as a potential method for determining in vitro equivalence of aerodynamic particle size distribution (APSD) profiles obtained from cascade impactor measurements. Because this test was designed with the intention of being used as a tool in regulatory review of drug applications, the capability of the test to detect differences in APSD profiles correctly and consistently was evaluated in a systematic way across a designed space of possible profiles. To establish a "base line," properties of the test in the simplest case of pairs of identical profiles were studied. Next, the test's performance was studied with pairs of profiles, where some difference was simulated in a systematic way on a single deposition site using realistic product profiles. The results obtained in these studies, which are presented in detail here, suggest that the chi-square ratio test in itself is not sufficient to determine equivalence of particle size distributions. This article, therefore, introduces the proposal to combine the chi-square ratio test with a test for impactor-sized mass based on Population Bioequivalence and describes methods for evaluating discrimination capabilities of the combined test. The approaches and results described in this article elucidate some of the capabilities and limitations of the original chi-square ratio test and provide rationale for development of additional tests capable of comparing APSD profiles of pharmaceutical aerosols.

  5. Food fortification: issues on quality assurance and impact evaluation in developing countries.

    PubMed

    Florentino, R

    2003-01-01

    Quality assurance and impact evaluation are essential components of a food fortification program and should be integrated in the fortification process. Quality assurance will ensure that the micronutrient meant to be delivered is indeed reaching the target population at the correct level. Impact evaluation will determine the effectiveness of food fortification as a strategy in controlling micronutrient deficiency and enable program planners to make decisions on the future of the program. In developing countries, both quality assurance and impact evaluation are often constrained not only by inadequacy of facilities as well as financial and manpower resources, but by unclear definition of objectives and inappropriate design. It is therefore necessary to consider the target audience for the quality assurance monitoring and impact evaluation in order to clearly define their objectives and in turn suit the design to these objectives, at the same time as the limitations in financial and manpower resources are considered.

  6. Transfer of knowledge from sound quality measurement to noise impact evaluation

    NASA Astrophysics Data System (ADS)

    Genuit, Klaus

    2004-05-01

    It is well known that the measurement and analysis of sound quality requires a complex procedure with consideration of the physical, psychoacoustical and psychological aspects of sound. Sound quality cannot be described only by a simple value based on A-weighted sound pressure level measurements. The A-weighted sound pressure level is sufficient to predict the probabilty that the human ear could be damaged by sound but the A-weighted level is not the correct descriptor for the annoyance of a complex sound situation given by several different sound events at different and especially moving positions (soundscape). On the one side, the consideration of the spectral distribution and the temporal pattern (psychoacoustics) is requested and, on the other side, the subjective attitude with respect to the sound situation, the expectation and experience of the people (psychology) have to be included in context with the complete noise impact evaluation. This paper describes applications of the newest methods of sound quality measurements-as it is well introduced at the car manufacturers-based on artifical head recordings and signal processing comparable to the human hearing used in noisy environments like community/traffic noise.

  7. Feasibility of peer assessment and clinical audit to self-regulate the quality of physiotherapy services: a mixed methods study

    PubMed Central

    Nijhuis-van der Sanden, Maria W G; Driehuis, Femke; Heerkens, Yvonne F; van der Vleuten, Cees P M; van der Wees, Philip J

    2017-01-01

    Objectives To evaluate the feasibility of a quality improvement programme aimed to enhance the client-centeredness, effectiveness and transparency of physiotherapy services by addressing three feasibility domains: (1) acceptability of the programme design, (2) appropriateness of the implementation strategy and (3) impact on quality improvement. Design Mixed methods study. Participants and setting 64 physiotherapists working in primary care, organised in a network of communities of practice in the Netherlands. Methods The programme contained: (1) two cycles of online self-assessment and peer assessment (PA) of clinical performance using client records and video-recordings of client communication followed by face-to-face group discussions, and (2) clinical audit assessing organisational performance. Assessment was based on predefined performance indicators which could be scored on a 5-point Likert scale. Discussions addressed performance standards and scoring differences. All feasibility domains were evaluated qualitatively with two focus groups and 10 in-depth interviews. In addition, we evaluated the impact on quality improvement quantitatively by comparing self-assessment and PA scores in cycles 1 and 2. Results We identified critical success features relevant to programme development and implementation, such as clarifying expectations at baseline, training in PA skills, prolonged engagement with video-assessment and competent group coaches. Self-reported impact on quality improvement included awareness of clinical and organisational performance, improved evidence-based practice and client-centeredness and increased motivation to self-direct quality improvement. Differences between self-scores and peer scores on performance indicators were not significant. Between cycles 1 and 2, scores for record keeping showed significant improvement, however not for client communication. Conclusions This study demonstrated that bottom-up initiatives to improve healthcare

  8. Comparison of Soil Quality Index Using Three Methods

    PubMed Central

    Mukherjee, Atanu; Lal, Rattan

    2014-01-01

    Assessment of management-induced changes in soil quality is important to sustaining high crop yield. A large diversity of cultivated soils necessitate identification development of an appropriate soil quality index (SQI) based on relative soil properties and crop yield. Whereas numerous attempts have been made to estimate SQI for major soils across the World, there is no standard method established and thus, a strong need exists for developing a user-friendly and credible SQI through comparison of various available methods. Therefore, the objective of this article is to compare three widely used methods to estimate SQI using the data collected from 72 soil samples from three on-farm study sites in Ohio. Additionally, challenge lies in establishing a correlation between crop yield versus SQI calculated either depth wise or in combination of soil layers as standard methodology is not yet available and was not given much attention to date. Predominant soils of the study included one organic (Mc), and two mineral (CrB, Ko) soils. Three methods used to estimate SQI were: (i) simple additive SQI (SQI-1), (ii) weighted additive SQI (SQI-2), and (iii) statistically modeled SQI (SQI-3) based on principal component analysis (PCA). The SQI varied between treatments and soil types and ranged between 0–0.9 (1 being the maximum SQI). In general, SQIs did not significantly differ at depths under any method suggesting that soil quality did not significantly differ for different depths at the studied sites. Additionally, data indicate that SQI-3 was most strongly correlated with crop yield, the correlation coefficient ranged between 0.74–0.78. All three SQIs were significantly correlated (r = 0.92–0.97) to each other and with crop yield (r = 0.65–0.79). Separate analyses by crop variety revealed that correlation was low indicating that some key aspects of soil quality related to crop response are important requirements for estimating SQI. PMID:25148036

  9. Assessing groundwater quality for irrigation using indicator kriging method

    NASA Astrophysics Data System (ADS)

    Delbari, Masoomeh; Amiri, Meysam; Motlagh, Masoud Bahraini

    2016-11-01

    One of the key parameters influencing sprinkler irrigation performance is water quality. In this study, the spatial variability of groundwater quality parameters (EC, SAR, Na+, Cl-, HCO3 - and pH) was investigated by geostatistical methods and the most suitable areas for implementation of sprinkler irrigation systems in terms of water quality are determined. The study was performed in Fasa county of Fars province using 91 water samples. Results indicated that all parameters are moderately to strongly spatially correlated over the study area. The spatial distribution of pH and HCO3 - was mapped using ordinary kriging. The probability of concentrations of EC, SAR, Na+ and Cl- exceeding a threshold limit in groundwater was obtained using indicator kriging (IK). The experimental indicator semivariograms were often fitted well by a spherical model for SAR, EC, Na+ and Cl-. For HCO3 - and pH, an exponential model was fitted to the experimental semivariograms. Probability maps showed that the risk of EC, SAR, Na+ and Cl- exceeding the given critical threshold is higher in lower half of the study area. The most proper agricultural lands for sprinkler irrigation implementation were identified by evaluating all probability maps. The suitable areas for sprinkler irrigation design were determined to be 25,240 hectares, which is about 34 percent of total agricultural lands and are located in northern and eastern parts. Overall the results of this study showed that IK is an appropriate approach for risk assessment of groundwater pollution, which is useful for a proper groundwater resources management.

  10. 7 CFR 58.133 - Methods for quality and wholesomeness determination.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... and Grading Service 1 Quality Specifications for Raw Milk § 58.133 Methods for quality and wholesomeness determination. (a) Appearance and odor. The appearance of acceptable raw milk shall be normal and...

  11. 7 CFR 58.133 - Methods for quality and wholesomeness determination.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... and Grading Service 1 Quality Specifications for Raw Milk § 58.133 Methods for quality and wholesomeness determination. (a) Appearance and odor. The appearance of acceptable raw milk shall be normal and...

  12. Landing flying qualities evaluation criteria for augmented aircraft

    NASA Technical Reports Server (NTRS)

    Radford, R. C.; Smith, R.; Bailey, R.

    1980-01-01

    The criteria evaluated were: Calspan Neal-Smith; Onstott (Northrop Time Domain); McDonnell-Douglas Equivalent System Approach; R. H. Smith Criterion. Each criterion was applied to the same set of longitudinal approach and landing flying qualities data. A revised version of the Neal-Smith criterion which is applicable to the landing task was developed and tested against other landing flying qualities data. Results indicated that both the revised Neal-Smith criterion and the Equivalent System Approach are good discriminators of pitch landing flying qualities; Neal-Smith has particular merit as a design guide, while the Equivalent System Approach is well suited for development of appropriate military specification requirements applicable to highly augmented aircraft.

  13. Intercomparison of methods for image quality characterization. II. Noise power spectrum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dobbins, James T. III; Samei, Ehsan; Ranger, Nicole T.

    Second in a two-part series comparing measurement techniques for the assessment of basic image quality metrics in digital radiography, in this paper we focus on the measurement of the image noise power spectrum (NPS). Three methods were considered: (1) a method published by Dobbins et al. [Med. Phys. 22, 1581-1593 (1995)] (2) a method published by Samei et al. [Med. Phys. 30, 608-622 (2003)], and (3) a new method sanctioned by the International Electrotechnical Commission (IEC 62220-1, 2003), developed as part of an international standard for the measurement of detective quantum efficiency. In addition to an overall comparison of themore » estimated NPS between the three techniques, the following factors were also evaluated for their effect on the measured NPS: horizontal versus vertical directional dependence, the use of beam-limiting apertures, beam spectrum, and computational methods of NPS analysis, including the region-of-interest (ROI) size and the method of ROI normalization. Of these factors, none was found to demonstrate a substantial impact on the amplitude of the NPS estimates ({<=}3.1% relative difference in NPS averaged over frequency, for each factor considered separately). Overall, the three methods agreed to within 1.6%{+-}0.8% when averaged over frequencies >0.15 mm{sup -1}.« less

  14. Impact of Pretreatment and Drying Methods on Quality Attributes of Onion Shreds

    PubMed Central

    Sahoo, Nihar R.; Pal, Uma S.; Sahoo, Dipika

    2015-01-01

    Summary Experiments were conducted on dry untreated onion shreds (2 mm thickness) or treated with salt (5% solution) and potassium metabisulphite (0.5% solution) in convective drier at 50 °C ((46±4) % relative humidity (RH)), 55 °C ((35±4) % RH), 60 °C ((28±4) % RH) and 65 °C ((20±4) % RH), heat pump-assisted convective drier at 35 °C ((32±2) % RH), 40 °C ((26±2) % RH), 45 °C ((19±2) % RH) and 50 °C ((15±2) % RH) and microwave-assisted convective drier at four microwave power levels, i.e. 120, 240, 360 and 480 W. The quality parameters of the dried onion shreds, namely rehydration ratio, colour difference, pyruvic and ascorbic acid contents and sensory scores were evaluated. The quality of dehydrated onion shreds was observed to be comparatively better when treated in heat pump drier at 50 °C, followed by that in microwave-assisted convective drier at 240 W and 50 °C, and last in convective drier at 60 °C. The onion shreds pretreated with potassium metabisulphite retained better colour of the dried product irrespective of drying methods. Therefore, heat pump drying may be recommended as one of the best drying methods for onion shreds, because it maintains the final product quality, which has practical importance for the food industry. PMID:27904332

  15. Evaluation of regional climate simulations for air quality modelling purposes

    NASA Astrophysics Data System (ADS)

    Menut, Laurent; Tripathi, Om P.; Colette, Augustin; Vautard, Robert; Flaounas, Emmanouil; Bessagnet, Bertrand

    2013-05-01

    In order to evaluate the future potential benefits of emission regulation on regional air quality, while taking into account the effects of climate change, off-line air quality projection simulations are driven using weather forcing taken from regional climate models. These regional models are themselves driven by simulations carried out using global climate models (GCM) and economical scenarios. Uncertainties and biases in climate models introduce an additional "climate modeling" source of uncertainty that is to be added to all other types of uncertainties in air quality modeling for policy evaluation. In this article we evaluate the changes in air quality-related weather variables induced by replacing reanalyses-forced by GCM-forced regional climate simulations. As an example we use GCM simulations carried out in the framework of the ERA-interim programme and of the CMIP5 project using the Institut Pierre-Simon Laplace climate model (IPSLcm), driving regional simulations performed in the framework of the EURO-CORDEX programme. In summer, we found compensating deficiencies acting on photochemistry: an overestimation by GCM-driven weather due to a positive bias in short-wave radiation, a negative bias in wind speed, too many stagnant episodes, and a negative temperature bias. In winter, air quality is mostly driven by dispersion, and we could not identify significant differences in either wind or planetary boundary layer height statistics between GCM-driven and reanalyses-driven regional simulations. However, precipitation appears largely overestimated in GCM-driven simulations, which could significantly affect the simulation of aerosol concentrations. The identification of these biases will help interpreting results of future air quality simulations using these data. Despite these, we conclude that the identified differences should not lead to major difficulties in using GCM-driven regional climate simulations for air quality projections.

  16. A novel orthoimage mosaic method using a weighted A∗ algorithm - Implementation and evaluation

    NASA Astrophysics Data System (ADS)

    Zheng, Maoteng; Xiong, Xiaodong; Zhu, Junfeng

    2018-04-01

    The implementation and evaluation of a weighted A∗ algorithm for orthoimage mosaic with UAV (Unmanned Aircraft Vehicle) imagery is proposed. The initial seam-line network is firstly generated by standard Voronoi Diagram algorithm; an edge diagram is generated based on DSM (Digital Surface Model) data; the vertices (conjunction nodes of seam-lines) of the initial network are relocated if they are on high objects (buildings, trees and other artificial structures); and the initial seam-lines are refined using the weighted A∗ algorithm based on the edge diagram and the relocated vertices. Our method was tested with three real UAV datasets. Two quantitative terms are introduced to evaluate the results of the proposed method. Preliminary results show that the method is suitable for regular and irregular aligned UAV images for most terrain types (flat or mountainous areas), and is better than the state-of-the-art method in both quality and efficiency based on the test datasets.

  17. Evaluation of Safety, Quality and Productivity in Construction

    NASA Astrophysics Data System (ADS)

    Usmen, M. A.; Vilnitis, M.

    2015-11-01

    This paper examines the success indicators of construction projects, safety, quality and productivity, in terms of their implications and impacts during and after construction. First safety is considered during construction with a focus on hazard identification and the prevention of occupational accidents and injuries on worksites. The legislation mandating safety programs, training and compliance with safety standards is presented and discussed. Consideration of safety at the design stage is emphasized. Building safety and the roles of building codes in prevention of structural failures are also covered in the paper together with factors affecting building failures and methods for their prevention. Quality is introduced in the paper from the perspective of modern total quality management. Concepts of quality management, quality control, quality assurance and Six Sigma and how they relate to building quality and structural integrity are discussed with examples. Finally, productivity concepts are presented with emphasis on effective project management to minimize loss of productivity, complimented by lean construction and lean Six Sigma principles. The paper concludes by synthesizing the relationships between safety, quality and productivity.

  18. Quality Control of Epidemiological Lectures Online: Scientific Evaluation of Peer Review

    PubMed Central

    Linkov, Faina; Lovalekar, Mita; LaPorte, Ronald

    2007-01-01

    Aim To examine the feasibility of using peer review for the quality control of online materials. Methods We analyzed the inter-rater agreement on the quality of epidemiological lectures online, based on the Global Health Network Supercourse lecture library. We examined the agreement among reviewers by looking at κ statistics and intraclass correlations. Seven expert reviewers examined and rated a random sample of 100 Supercourse lectures. Their reviews were compared with the reviews of the lay Supercourse reviewers. Results Both expert and non-expert reviewers rated lectures very highly, with a mean overall score of 4 out of 5. Kappa (κ) statistic and intraclass correlations indicated that inter-rater agreement for experts and non-experts was surprisingly low (below 0.4). Conclusions To our knowledge, this was the first time that poor inter-rater agreement was demonstrated for the Internet lectures. Future research studies need to evaluate the alternatives to the peer review system, especially for online materials. PMID:17436390

  19. Effect of different cooking methods on minerals, vitamins and nutritional quality indices of kutum roach (Rutilus frisii kutum).

    PubMed

    Hosseini, Hedayat; Mahmoudzadeh, Maryam; Rezaei, Masoud; Mahmoudzadeh, Leila; Khaksar, Ramin; Khosroshahi, Nader Karimian; Babakhani, Aria

    2014-04-01

    In this study, the influence of four cooking methods (baking, boiling, microwaving and frying) was evaluated on the nutritional value of kutum roach. Proximate, fatty acid composition, vitamin and mineral contents and also nutritional quality indices (NQI) of kutum roach were investigated before and after cooking treatment. All treated samples showed increase in protein, ash and lipid contents and decrease in the content of total omega-3 fatty acids (n-3) in comparison to raw fish fillets (control group). Cooking methods had no significant effect on omega-6 fatty acids (n-6) except for frying that increased it. Nonetheless, all of the cooking methods reduced vitamin B1, A and D contents. Boiling significantly decreased mineral contents including Na, K, P and Zn. Considering the overall nutritional quality indices, vitamin and mineral contents, baking is the best cooking method among other applied methods. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Modern methods for the quality management of high-rate melt solidification

    NASA Astrophysics Data System (ADS)

    Vasiliev, V. A.; Odinokov, S. A.; Serov, M. M.

    2016-12-01

    The quality management of high-rate melt solidification needs combined solution obtained by methods and approaches adapted to a certain situation. Technological audit is recommended to estimate the possibilities of the process. Statistical methods are proposed with the choice of key parameters. Numerical methods, which can be used to perform simulation under multifactor technological conditions, and an increase in the quality of decisions are of particular importance.