Sample records for quality factor q-factor

  1. Evaluating signal and noise spectral density of a qPlus sensor with an active feedback control

    NASA Astrophysics Data System (ADS)

    Lee, Manhee; An, Sangmin; Jhe, Wonho

    2018-05-01

    Q-control technique enables to actively change the quality factor of the probe oscillation in dynamic atomic force microscopy. The Q-control is realized by adding a self-feedback loop into the original actuation-detection system, in which a damping force with controllable damping coefficient in magnitude and sign is applied to the oscillating probe. While the applied force alters the total damping interaction and thus the overall `signal' of the probe motion, the added feedback system changes the `noise' of the motion as well. Here, we systematically investigate the signal, the noise, and the signal-to-noise ratio of the qPlus sensor under the active Q-control. We quantify the noise of the qPlus motion by measuring the noise spectral density, which is reproduced by a harmonic oscillator model including the thermal and the measurement noises. We show that the noise signal increases with the quality factor controlled, scaling as the square root of the quality factor. Because the overall signal is linearly proportional to the quality factor, the signal-to-noise ratio scales as the square root of the quality factor. The Q-controlled qPlus with a highly enhanced Q, up to 10,000 in air, leads to the minimum detectable force gradient of 0.001 N/m, which would enhance the capability of the qPlus sensor for atomic force microscopy and spectroscopy.

  2. Microcrystalline diamond cylindrical resonators with quality-factor up to 0.5 million

    NASA Astrophysics Data System (ADS)

    Saito, Daisuke; Yang, Chen; Heidari, Amir; Najar, Hadi; Lin, Liwei; Horsley, David A.

    2016-02-01

    We demonstrate high quality-factor 1.5 mm diameter batch-fabricated microcrystalline diamond cylindrical resonators (CR) with quality-factors limited by thermoelastic damping (TED) and surface loss. Resonators were fabricated 2.6 and 5.3 μm thick in-situ boron-doped microcrystalline diamond films deposited using hot filament chemical vapor deposition. The quality-factor (Q) of as-fabricated CR's was found to increase with the resonator diameter and diamond thickness. Annealing the CRs at 700 °C in a nitrogen atmosphere led to a three-fold increase in Q, a result we attribute to thinning of the diamond layer via reaction with residual O2 in the annealing furnace. Post-anneal Q exceeding 0.5 million (528 000) was measured at the 19 kHz elliptical wineglass modes, producing a ring-down time of 8.9 s. A model for Q versus diamond thickness and resonance frequency is developed including the effects of TED and surface loss. Measured quality factors are shown to agree with the predictions of this model.

  3. Analysis of Thickness and Quality factor of a Double Paddle Oscillator at Room Temperature.

    PubMed

    Shakeel, Hamza; Metcalf, Thomas H; Pomeroy, J M

    2016-01-01

    In this paper, we evaluate the quality (Q) factor and the resonance frequency of a double paddle oscillator (DPO) with different thickness using analytical, computational and experimental methods. The study is carried out for the 2 nd anti-symmetric resonance mode that provides extremely high experimental Q factors on the order of 10 5 . The results show that both the Q factor and the resonance frequency of a DPO increase with the thickness at room temperature.

  4. Comparison of the mean quality factors for astronauts calculated using the Q-functions proposed by ICRP, ICRU, and NASA

    NASA Astrophysics Data System (ADS)

    Sato, T.; Endo, A.; Niita, K.

    2013-07-01

    For the estimation of the radiation risk for astronauts, not only the organ absorbed doses but also their mean quality factors must be evaluated. Three functions have been proposed by different organizations for expressing the radiation quality, including the Q(L), Q(y), and QNASA(Z, E) relationships as defined in International Committee of Radiological Protection (ICRP) Publication 60, International Commission on Radiation Units and Measurements (ICRU) Report 40, and National Aeronautics and Space Administration (NASA) TP-2011-216155, respectively. The Q(L) relationship is the most simple and widely used for space dosimetry, but the use of the latter two functions enables consideration of the difference in the track structure of various charged particles during the risk estimation. Therefore, we calculated the mean quality factors in organs and tissues in ICRP/ICRU reference voxel phantoms for the isotropic exposure to various mono-energetic particles using the three Q-functions. The Particle and Heavy Ion Transport code System PHITS was employed to simulate the particle motions inside the phantoms. The effective dose equivalents and the phantom-averaged effective quality factors for the astronauts were then estimated from the calculated mean quality factors multiplied by the fluence-to-dose conversion coefficients and cosmic-ray fluxes inside a spacecraft. It was found from the calculations that QNASA generally gives the largest values for the phantom-averaged effective quality factors among the three Q-functions for neutron, proton, and lighter-ion irradiation, whereas Q(L) provides the largest values for heavier-ion irradiation. Overall, the introduction of QNASA instead of Q(L) or Q(y) in astronaut dosimetry results in the increase the effective dose equivalents because the majority of the doses are composed of the contributions from protons and neutrons, although this tendency may change by the calculation conditions.

  5. SU-F-BRD-15: Quality Correction Factors in Scanned Or Broad Proton Therapy Beams Are Indistinguishable

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sorriaux, J; Lee, J; ICTEAM Institute, Universite catholique de Louvain, Louvain-la-Neuve

    2015-06-15

    Purpose: The IAEA TRS-398 code of practice details the reference conditions for reference dosimetry of proton beams using ionization chambers and the required beam quality correction factors (kQ). Pencil beam scanning (PBS) requires multiple spots to reproduce the reference conditions. The objective is to demonstrate, using Monte Carlo (MC) calculations, that kQ factors for broad beams can be used for scanned beams under the same reference conditions with no significant additional uncertainty. We consider hereafter the general Alfonso formalism (Alfonso et al, 2008) for non-standard beam. Methods: To approach the reference conditions and the associated dose distributions, PBS must combinemore » many pencil beams with range modulation and shaping techniques different than those used in passive systems (broad beams). This might lead to a different energy spectrum at the measurement point. In order to evaluate the impact of these differences on kQ factors, ion chamber responses are computed with MC (Geant4 9.6) in a dedicated scanned pencil beam (Q-pcsr) producing a 10×10cm2 composite field with a flat dose distribution from 10 to 16 cm depth. Ion chamber responses are also computed by MC in a broad beam with quality Q-ds (double scattering). The dose distribution of Q -pcsr matches the dose distribution of Q-ds. k-(Q-pcsr,Q-ds) is computed for a 2×2×0.2cm{sup 3} idealized air cavity and a realistic plane-parallel ion chamber (IC). Results: Under reference conditions, quality correction factors for a scanned composite field versus a broad beam are the same for air cavity dose response, k-(Q-pcsr,Q-ds) =1.001±0.001 and for a Roos IC, k-(Q-pcsr,Q-ds) =0.999±0.005. Conclusion: Quality correction factors for ion chamber response in scanned and broad proton therapy beams are identical under reference conditions within the calculation uncertainties. The results indicate that quality correction factors published in IAEA TRS-398 can be used for scanned beams in the SOBP of a high-energy proton beam. Jefferson Sorriaux is financed by the Walloon Region under the convention 1217662. Jefferson Sorriaux is sponsored by a public-private partnership IBA - Walloon Region.« less

  6. [Uncertainty of cross calibration-applied beam quality conversion factor for the Japan Society of Medical Physics 12].

    PubMed

    Kinoshita, Naoki; Kita, Akinobu; Takemura, Akihiro; Nishimoto, Yasuhiro; Adachi, Toshiki

    2014-09-01

    The uncertainty of the beam quality conversion factor (k(Q,Q0)) of standard dosimetry of absorbed dose to water in external beam radiotherapy 12 (JSMP12) is determined by combining the uncertainty of each beam quality conversion factor calculated for each type of ionization chamber. However, there is no guarantee that ionization chambers of the same type have the same structure and thickness, so there may be individual variations. We evaluated the uncertainty of k(Q,Q0) for JSMP12 using an ionization chamber dosimeter and linear accelerator without a specific device or technique in consideration of the individual variation of ionization chambers and in clinical radiation field. The cross calibration formula was modified and the beam quality conversion factor for the experimental values [(k(Q,Q0))field] determined using the modified formula. It's uncertainty was calculated to be 1.9%. The differences between (k(Q,Q0))field of experimental values and k(Q,Q0) for Japan Society of Medical Physics 12 (JSMP12) were 0.73% and 0.88% for 6- and 10-MV photon beams, respectively, remaining within ± 1.9%. This showed k(Q,Q0) for JSMP12 to be consistent with (k(Q,Q0))field of experimental values within the estimated uncertainty range. Although inter-individual differences may be generated, even when the same type of ionized chamber is used, k(Q,Q0) for JSMP12 appears to be consistent within the estimated uncertainty range of (k(Q,Q0)field.

  7. Microcrystalline diamond cylindrical resonators with quality-factor up to 0.5 million

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saito, Daisuke; Yang, Chen; Lin, Liwei

    2016-02-01

    We demonstrate high quality-factor 1.5 mm diameter batch-fabricated microcrystalline diamond cylindrical resonators (CR) with quality-factors limited by thermoelastic damping (TED) and surface loss. Resonators were fabricated 2.6 and 5.3 μm thick in-situ boron-doped microcrystalline diamond films deposited using hot filament chemical vapor deposition. The quality-factor (Q) of as-fabricated CR's was found to increase with the resonator diameter and diamond thickness. Annealing the CRs at 700 °C in a nitrogen atmosphere led to a three-fold increase in Q, a result we attribute to thinning of the diamond layer via reaction with residual O{sub 2} in the annealing furnace. Post-anneal Q exceeding 0.5 million (528 000)more » was measured at the 19 kHz elliptical wineglass modes, producing a ring-down time of 8.9 s. A model for Q versus diamond thickness and resonance frequency is developed including the effects of TED and surface loss. Measured quality factors are shown to agree with the predictions of this model.« less

  8. Accurate Determination of the Q Quality Factor in Magnetoelastic Resonant Platforms for Advanced Biological Detection.

    PubMed

    Lopes, Ana Catarina; Sagasti, Ariane; Lasheras, Andoni; Muto, Virginia; Gutiérrez, Jon; Kouzoudis, Dimitris; Barandiarán, José Manuel

    2018-03-16

    The main parameters of magnetoelastic resonators in the detection of chemical (i.e., salts, gases, etc.) or biological (i.e., bacteria, phages, etc.) agents are the sensitivity S (or external agent change magnitude per Hz change in the resonance frequency) and the quality factor Q of the resonance. We present an extensive study on the experimental determination of the Q factor in such magnetoelastic resonant platforms, using three different strategies: (a) analyzing the real and imaginary components of the susceptibility at resonance; (b) numerical fitting of the modulus of the susceptibility; (c) using an exact mathematical expression for the real part of the susceptibility. Q values obtained by the three methods are analyzed and discussed, aiming to establish the most adequate one to accurately determine the quality factor of the magnetoelastic resonance.

  9. Accurate Determination of the Q Quality Factor in Magnetoelastic Resonant Platforms for Advanced Biological Detection

    PubMed Central

    Lopes, Ana Catarina; Sagasti, Ariane; Lasheras, Andoni; Muto, Virginia; Gutiérrez, Jon; Kouzoudis, Dimitris; Barandiarán, José Manuel

    2018-01-01

    The main parameters of magnetoelastic resonators in the detection of chemical (i.e., salts, gases, etc.) or biological (i.e., bacteria, phages, etc.) agents are the sensitivity S (or external agent change magnitude per Hz change in the resonance frequency) and the quality factor Q of the resonance. We present an extensive study on the experimental determination of the Q factor in such magnetoelastic resonant platforms, using three different strategies: (a) analyzing the real and imaginary components of the susceptibility at resonance; (b) numerical fitting of the modulus of the susceptibility; (c) using an exact mathematical expression for the real part of the susceptibility. Q values obtained by the three methods are analyzed and discussed, aiming to establish the most adequate one to accurately determine the quality factor of the magnetoelastic resonance. PMID:29547578

  10. Q factor limitation at short wavelength (around 300 nm) in III-nitride-on-silicon photonic crystal cavities

    NASA Astrophysics Data System (ADS)

    Tabataba-Vakili, Farsane; Roland, Iannis; Tran, Thi-Mo; Checoury, Xavier; El Kurdi, Moustafa; Sauvage, Sébastien; Brimont, Christelle; Guillet, Thierry; Rennesson, Stéphanie; Duboz, Jean-Yves; Semond, Fabrice; Gayral, Bruno; Boucaud, Philippe

    2017-09-01

    III-nitride-on-silicon L3 photonic crystal cavities with resonances down to 315 nm and quality factors (Q) up to 1085 at 337 nm have been demonstrated. The reduction of the quality factor with decreasing wavelength is investigated. Besides the quantum well absorption below 340 nm, a noteworthy contribution is attributed to the residual absorption present in thin AlN layers grown on silicon, as measured by spectroscopic ellipsometry. This residual absorption ultimately limits the Q factor to around 2000 at 300 nm when no active layer is present.

  11. A radiation quality correction factor k for well-type ionization chambers for the measurement of the reference air kerma rate of (60)Co HDR brachytherapy sources.

    PubMed

    Schüller, Andreas; Meier, Markus; Selbach, Hans-Joachim; Ankerhold, Ulrike

    2015-07-01

    The aim of this study was to investigate whether a chamber-type-specific radiation quality correction factor kQ can be determined in order to measure the reference air kerma rate of (60)Co high-dose-rate (HDR) brachytherapy sources with acceptable uncertainty by means of a well-type ionization chamber calibrated for (192)Ir HDR sources. The calibration coefficients of 35 well-type ionization chambers of two different chamber types for radiation fields of (60)Co and (192)Ir HDR brachytherapy sources were determined experimentally. A radiation quality correction factor kQ was determined as the ratio of the calibration coefficients for (60)Co and (192)Ir. The dependence on chamber-to-chamber variations, source-to-source variations, and source strength was investigated. For the PTW Tx33004 (Nucletron source dosimetry system (SDS)) well-type chamber, the type-specific radiation quality correction factor kQ is 1.19. Note that this value is valid for chambers with the serial number, SN ≥ 315 (Nucletron SDS SN ≥ 548) onward only. For the Standard Imaging HDR 1000 Plus well-type chambers, the type-specific correction factor kQ is 1.05. Both kQ values are independent of the source strengths in the complete clinically relevant range. The relative expanded uncertainty (k = 2) of kQ is UkQ = 2.1% for both chamber types. The calibration coefficient of a well-type chamber for radiation fields of (60)Co HDR brachytherapy sources can be calculated from a given calibration coefficient for (192)Ir radiation by using a chamber-type-specific radiation quality correction factor kQ. However, the uncertainty of a (60)Co calibration coefficient calculated via kQ is at least twice as large as that for a direct calibration with a (60)Co source.

  12. Frequency dependent Lg attenuation in south-central Alaska

    USGS Publications Warehouse

    McNamara, D.E.

    2000-01-01

    The characteristics of seismic energy attenuation are determined using high frequency Lg waves from 27 crustal earthquakes, in south-central Alaska. Lg time-domain amplitudes are measured in five pass-bands and inverted to determine a frequency-dependent quality factor, Q(f), model for south-central Alaska. The inversion in this study yields the frequency-dependent quality factor, in the form of a power law: Q(f) = Q0fη = 220(±30) f0.66(±0.09) (0.75≤f≤12Hz). The results from this study are remarkably consistent with frequency dependent quality factor estimates, using local S-wave coda, in south-central Alaska. The consistency between S-coda Q(f) and Lg Q(f) enables constraints to be placed on the mechanism of crustal attenuation in south-central Alaska. For the range of frequencies considered in this study both scattering and intrinsic attenuation mechanisms likely play an equal role.

  13. Fabrication of a microresonator-fiber assembly maintaining a high-quality factor by CO₂ laser welding.

    PubMed

    Fang, Zhiwei; Lin, Jintian; Wang, Min; Liu, Zhengming; Yao, Jinping; Qiao, Lingling; Cheng, Ya

    2015-10-19

    We demonstrate fabrication of a microtoroid resonator of a high-quality (high-Q) factor using femtosecond laser three-dimensional (3D) micromachining. A fiber taper is reliably assembled to the microtoroid using CO2 laser welding. Specifically, we achieve a high-Q-factor of 2.12 × 10(6) in the microresonator-fiber assembly by optimizing the contact position between the fiber taper and the microtoroid.

  14. Psychometric properties of the Portuguese version of the Quality of Life Questionnaire (QOL-Q).

    PubMed

    Albuquerque, Cristina P

    2012-09-01

    This study analyzes the psychometric properties of the Portuguese version of the Quality of Life Questionnaire (QOL-Q; Quality of Life Questionnaire Manual - 1993 Manual and 2004 Revision. 2004, IDS Publishing Company, Worthington, OH; Schalock & Keith 2004). The analysis of the factorial structure was carried out on a sample of 304 adults with intellectual disabilities, through the use of confirmatory (CFA) and exploratory (EFA) factor analysis. The relationships of the QOL-Q with life satisfaction and self-concept measures were determined in groups composed of respectively 72 and 78 adults with intellectual disabilities. Confirmatory factorial analysis indicated a poor adjustment of the original factor structure to the Portuguese data. EFA indicated the existence of four factors, which include 30 items, and that were also supported by CFA. The total score of the QOL-Q revealed a reduced correlation with life satisfaction, and a moderate correlation with the self-concept. The Portuguese version of the QOL-Q shows satisfactory psychometric properties, but also some limitations. © 2012 Blackwell Publishing Ltd.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schüller, Andreas, E-mail: andreas.schueller@ptb.de; Meier, Markus; Selbach, Hans-Joachim

    Purpose: The aim of this study was to investigate whether a chamber-type-specific radiation quality correction factor k{sub Q} can be determined in order to measure the reference air kerma rate of {sup 60}Co high-dose-rate (HDR) brachytherapy sources with acceptable uncertainty by means of a well-type ionization chamber calibrated for {sup 192}Ir HDR sources. Methods: The calibration coefficients of 35 well-type ionization chambers of two different chamber types for radiation fields of {sup 60}Co and {sup 192}Ir HDR brachytherapy sources were determined experimentally. A radiation quality correction factor k{sub Q} was determined as the ratio of the calibration coefficients for {supmore » 60}Co and {sup 192}Ir. The dependence on chamber-to-chamber variations, source-to-source variations, and source strength was investigated. Results: For the PTW Tx33004 (Nucletron source dosimetry system (SDS)) well-type chamber, the type-specific radiation quality correction factor k{sub Q} is 1.19. Note that this value is valid for chambers with the serial number, SN ≥ 315 (Nucletron SDS SN ≥ 548) onward only. For the Standard Imaging HDR 1000 Plus well-type chambers, the type-specific correction factor k{sub Q} is 1.05. Both k{sub Q} values are independent of the source strengths in the complete clinically relevant range. The relative expanded uncertainty (k = 2) of k{sub Q} is U{sub k{sub Q}} = 2.1% for both chamber types. Conclusions: The calibration coefficient of a well-type chamber for radiation fields of {sup 60}Co HDR brachytherapy sources can be calculated from a given calibration coefficient for {sup 192}Ir radiation by using a chamber-type-specific radiation quality correction factor k{sub Q}. However, the uncertainty of a {sup 60}Co calibration coefficient calculated via k{sub Q} is at least twice as large as that for a direct calibration with a {sup 60}Co source.« less

  16. Active tuning of high-Q dielectric metasurfaces

    DOE PAGES

    Parry, Matthew; Komar, Andrei; Hopkins, Ben; ...

    2017-08-02

    Here, we demonstrate the active tuning of all-dielectric metasurfaces exhibiting high-quality factor (high-Q) resonances. The active control is provided by embedding the asymmetric silicon meta-atoms with liquid crystals, which allows the relative index of refraction to be controlled through heating. It is found that high quality factor resonances (Q = 270 ± 30) can be tuned over more than three resonance widths. Our results demonstrate the feasibility of using all-dielectric metasurfaces to construct tunable narrow-band filters.

  17. Improving the Optical Quality Factor of the WGM Resonator

    NASA Technical Reports Server (NTRS)

    Savchenkov, Anatoliy; Matsko, Andrey; Iltchenko, Vladimir

    2008-01-01

    Resonators usually are characterized with two partially dependent values: finesse (F) and quality factor (Q). The finesse of an empty Fabry-Perot (FP) resonator is defined solely by the quality of its mirrors and is calculated as F=piR(exp 1/2)/(1-R). The maximum up-to-date value of reflectivity R approximately equal to 1 - 1.6 x 10(exp -6) is achieved with dielectric mirrors. An FP resonator made with the mirrors has finesse F=1.9 x 10(exp 6). Further practical increase of the finesse of FP resonators is problematic because of the absorption and the scattering of light in the mirror material through fundamental limit on the reflection losses given by the internal material losses and by thermodynamic density fluctuations on the order of parts in 109. The quality factor of a resonator depends on both its finesse and its geometrical size. A one-dimensional FP resonator has Q=2 F L/lambda, where L is the distance between the mirrors and lambda is the wavelength. It is easy to see that the quality factor of the resonator is unlimited because L is unlimited. F and Q are equally important. In some cases, finesse is technically more valuable than the quality factor. For instance, buildup of the optical power inside the resonator, as well as the Purcell factor, is proportional to finesse. Sometimes, however, the quality factor is more valuable. For example, inverse threshold power of intracavity hyperparametric oscillation is proportional to Q(exp 2) and efficiency of parametric frequency mixing is proportional to Q(exp 3). Therefore, it is important to know both the maximally achievable finesse and quality factor values of a resonator. Whispering gallery mode (WGM) resonators are capable of achieving larger finesse compared to FP resonators. For instance, fused silica resonators with finesse 2.3 x 10(exp 6) and 2.8 x 10(exp 6) have been demonstrated. Crystalline WGM resonators reveal even larger finesse values, F=6.3 x 10(exp 6), because of low attenuation of light in the transparent optical crystals. The larger values of F and Q result in the enhancement of various nonlinear processes. Low-threshold Raman lasing, optomechanical oscillations, frequency doubling, and hyperparametric oscillations based on these resonators have been recently demonstrated. Theory predicts a possibility of nearly 10(exp 14) room-temperature optical Q-factors of optical crystalline WGM resonators, which correspond to finesse levels higher than 10(exp 9). Experiments have shown numbers a thousand times lower than that. The difference occurs due to media imperfections. To substantially reduce the optical losses caused by the imperfections, a specific, multi-step, asymptotic processing of the resonator is implemented. The technique has been initially developed to reduce microwave absorption in dielectric resonators. One step of the process consists of mechanical polishing performed after high temperature annealing. Several steps repeat one after another to lead to significant reduction in optical attenuation and, as a result, to the increase of Q-factor as well as finesse of the resonator which demonstrates a CaF2 WGM resonator with F greater than 10(exp 7) and Q greater than 10(exp 11).

  18. Quench-induced degradation of the quality factor in superconducting resonators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Checchin, M.; Martinello, M.; Romanenko, A.

    Quench of superconducting radio-frequency cavities frequently leads to the lowered quality factor Q 0, which had been attributed to the additional trapped magnetic flux. Here we demonstrate that the origin of this magnetic flux is purely extrinsic to the cavity by showing no extra dissipation (unchanged Q 0) after quenching in zero magnetic field, which allows us to rule out intrinsic mechanisms of flux trapping such as generation of thermal currents or trapping of the rf field. We also show the clear relation of dissipation introduced by quenching to the orientation of the applied magnetic field and the possibility tomore » fully recover the quality factor by requenching in the compensated field. We discover that for larger values of the ambient field, the Q-factor degradation may become irreversible by this technique, likely due to the outward flux migration beyond the normal zone opening during quench. Lastly, our findings are of special practical importance for accelerators based on low- and medium-beta accelerating structures residing close to focusing magnets, as well as for all high-Q cavity-based accelerators.« less

  19. Quench-induced degradation of the quality factor in superconducting resonators

    DOE PAGES

    Checchin, M.; Martinello, M.; Romanenko, A.; ...

    2016-04-28

    Quench of superconducting radio-frequency cavities frequently leads to the lowered quality factor Q 0, which had been attributed to the additional trapped magnetic flux. Here we demonstrate that the origin of this magnetic flux is purely extrinsic to the cavity by showing no extra dissipation (unchanged Q 0) after quenching in zero magnetic field, which allows us to rule out intrinsic mechanisms of flux trapping such as generation of thermal currents or trapping of the rf field. We also show the clear relation of dissipation introduced by quenching to the orientation of the applied magnetic field and the possibility tomore » fully recover the quality factor by requenching in the compensated field. We discover that for larger values of the ambient field, the Q-factor degradation may become irreversible by this technique, likely due to the outward flux migration beyond the normal zone opening during quench. Lastly, our findings are of special practical importance for accelerators based on low- and medium-beta accelerating structures residing close to focusing magnets, as well as for all high-Q cavity-based accelerators.« less

  20. Quench-Induced Degradation of the Quality Factor in Superconducting Resonators

    NASA Astrophysics Data System (ADS)

    Checchin, M.; Martinello, M.; Romanenko, A.; Grassellino, A.; Sergatskov, D. A.; Posen, S.; Melnychuk, O.; Zasadzinski, J. F.

    2016-04-01

    Quench of superconducting radio-frequency cavities frequently leads to the lowered quality factor Q0 , which had been attributed to the additional trapped magnetic flux. Here we demonstrate that the origin of this magnetic flux is purely extrinsic to the cavity by showing no extra dissipation (unchanged Q0) after quenching in zero magnetic field, which allows us to rule out intrinsic mechanisms of flux trapping such as generation of thermal currents or trapping of the rf field. We also show the clear relation of dissipation introduced by quenching to the orientation of the applied magnetic field and the possibility to fully recover the quality factor by requenching in the compensated field. We discover that for larger values of the ambient field, the Q -factor degradation may become irreversible by this technique, likely due to the outward flux migration beyond the normal zone opening during quench. Our findings are of special practical importance for accelerators based on low- and medium-β accelerating structures residing close to focusing magnets, as well as for all high-Q cavity-based accelerators.

  1. Systematic uncertainties in RF-based measurement of superconducting cavity quality factors

    DOE PAGES

    Holzbauer, J. P.; Pischalnikov, Yu.; Sergatskov, D. A.; ...

    2016-05-10

    Q 0 determinations based on RF power measurements are subject to at least three potentially large systematic effects that have not been previously appreciated. Here, instrumental factors that can systematically bias RF based measurements of Q 0 are quantified and steps that can be taken to improve the determination of Q 0 are discussed.

  2. On the tunability of quality-factor for optical Tamm plasmon modes

    NASA Astrophysics Data System (ADS)

    Kumar, Samir; Das, Ritwick

    2017-09-01

    We present a comprehensive investigation to ascertain the impact of gold and silver films on modifying the quality-factor (Q-factor) of optical Tamm-plasmon (OTP) resonance in a metal-distributed Bragg reflector (M-DBR) geometry. Here, OTP mode is excited using direct incidence of white-light-source at normal incidence as well as oblique incidence on M-DBR geometry. The lifetime of OTP in gold and silver deposited films on DBR mirror was determined from OTP resonance linewidth. The lifetime and the Q-factor of OTP modes are found to depend on DBR bilayers, metal film thickness as well as on different plasmon active metals. This finding would facilitate tuning the Q-factor and consequently, the lifetime of OTP modes for various applications in all-optical switches and modulators. In addition, we discuss the spectral characteristics of OTP modes excited using normal and oblique incident of source.

  3. Direct determination of k Q factors for cylindrical and plane-parallel ionization chambers in high-energy electron beams from 6 MeV to 20 MeV.

    PubMed

    Krauss, A; Kapsch, R-P

    2018-02-06

    For the ionometric determination of the absorbed dose to water, D w , in high-energy electron beams from a clinical accelerator, beam quality dependent correction factors, k Q , are required. By using a water calorimeter, these factors can be determined experimentally and potentially with lower standard uncertainties than those of the calculated k Q factors, which are tabulated in various dosimetry protocols. However, one of the challenges of water calorimetry in electron beams is the small measurement depths in water, together with the steep dose gradients present especially at lower energies. In this investigation, water calorimetry was implemented in electron beams to determine k Q factors for different types of cylindrical and plane-parallel ionization chambers (NE2561, NE2571, FC65-G, TM34001) in 10 cm  ×  10 cm electron beams from 6 MeV to 20 MeV (corresponding beam quality index R 50 ranging from 1.9 cm to 7.5 cm). The measurements were carried out using the linear accelerator facility of the Physikalisch-Technische Bundesanstalt. Relative standard uncertainties for the k Q factors between 0.50% for the 20 MeV beam and 0.75% for the 6 MeV beam were achieved. For electron energies above 8 MeV, general agreement was found between the relative electron energy dependencies of the k Q factors measured and those derived from the AAPM TG-51 protocol and recent Monte Carlo-based studies, as well as those from other experimental investigations. However, towards lower energies, discrepancies of up to 2.0% occurred for the k Q factors of the TM34001 and the NE2571 chamber.

  4. Direct determination of k Q factors for cylindrical and plane-parallel ionization chambers in high-energy electron beams from 6 MeV to 20 MeV

    NASA Astrophysics Data System (ADS)

    Krauss, A.; Kapsch, R.-P.

    2018-02-01

    For the ionometric determination of the absorbed dose to water, D w, in high-energy electron beams from a clinical accelerator, beam quality dependent correction factors, k Q, are required. By using a water calorimeter, these factors can be determined experimentally and potentially with lower standard uncertainties than those of the calculated k Q factors, which are tabulated in various dosimetry protocols. However, one of the challenges of water calorimetry in electron beams is the small measurement depths in water, together with the steep dose gradients present especially at lower energies. In this investigation, water calorimetry was implemented in electron beams to determine k Q factors for different types of cylindrical and plane-parallel ionization chambers (NE2561, NE2571, FC65-G, TM34001) in 10 cm  ×  10 cm electron beams from 6 MeV to 20 MeV (corresponding beam quality index R 50 ranging from 1.9 cm to 7.5 cm). The measurements were carried out using the linear accelerator facility of the Physikalisch-Technische Bundesanstalt. Relative standard uncertainties for the k Q factors between 0.50% for the 20 MeV beam and 0.75% for the 6 MeV beam were achieved. For electron energies above 8 MeV, general agreement was found between the relative electron energy dependencies of the k Q factors measured and those derived from the AAPM TG-51 protocol and recent Monte Carlo-based studies, as well as those from other experimental investigations. However, towards lower energies, discrepancies of up to 2.0% occurred for the k Q factors of the TM34001 and the NE2571 chamber.

  5. High-Q microwave photonic filter with a tuned modulator.

    PubMed

    Capmany, J; Mora, J; Ortega, B; Pastor, D

    2005-09-01

    We propose the use of tuned electro-optic or electroabsorption external modulators to implement high-quality (high-Q) factor, single-bandpass photonic filters for microwave signals. Using this approach, we experimentally demonstrate a transversal finite impulse response with a Q factor of 237. This is to our knowledge the highest value ever reported for a passive finite impulse-response microwave photonic filter.

  6. All-dielectric metasurface analogue of electromagnetically induced transparency [High Quality Factor Fano-Resonant All-Dielectric Metamaterials

    DOE PAGES

    Yang, Yuanmu; Kravchenko, Ivan I.; Briggs, Dayrl P.; ...

    2014-12-16

    Fano-resonant plasmonic metamaterials and nanostructures have become a major focus of the nanophotonics fields over the past several years due their ability to produce high quality factor (Q-factor) resonances. The origin of such resonances is the interference between a broad and narrow resonance, ultimately allowing suppression of radiative damping. However, Fano-resonant plasmonic structures still suffer non-radiative damping due to Ohmic loss, ultimately limiting the achievable Q-factors to values less than ~10. Here, we report experimental demonstration of Fano-resonant silicon-based metamaterials that have a response that mimics the electromagnetically induced transparency (EIT) found in atomic systems. Due to extremely low absorptionmore » loss, a record-high quality factor (Q-factor) of 306 was experimentally observed. Furthermore, the unit cell of the metamaterial was designed with a feed-gap which results in strong local field enhancement in the surrounding medium resulting in strong light-matter interaction. This allows the metamaterial to serve as a refractive index sensor with a figure-of-merit (FOM) of 101, far exceeding the performance of previously demonstrated localized surface plasmon resonance sensors.« less

  7. A high-quality factor of 267 000 micromechanical silicon resonator utilizing TED-free torsional vibration mode

    NASA Astrophysics Data System (ADS)

    Nakamura, K.; Naito, Y.; Onishi, K.; Kawakatsu, H.

    2012-12-01

    In industrial applications of a micromechanical silicon resonator as a physical sensor, a high-quality factor Q and a low-temperature coefficient of Q (TCQ) are required for high sensitivity in a wide temperature range. Although the newly developed thin film encapsulation technique enables a beam to operate with low viscous damping in a vacuum cavity, the Q of a flexural vibration mode is limited by thermo-elastic damping (TED). We proposed a torsional beam resonator which features both a high Q and a low TCQ because theoretically the torsional vibration mode does not suffer from TED. From experiments, Q of 267 000 and TCQ of 1.4 for the 20 MHz torsional vibration mode were observed which were superior to those of the flexural mode. The pressure of the residual gas in the cavity of only 20 pl volume, which is one of the energy loss factors limiting the Q, was successfully estimated to be 1-14 Pa. Finally, the possibilities of improving the Q and the difference of the measured TCQ from a theoretical value were discussed.

  8. Imaging contrast and tip-sample interaction of non-contact amplitude modulation atomic force microscopy with Q-control

    NASA Astrophysics Data System (ADS)

    Shi, Shuai; Guo, Dan; Luo, Jianbin

    2017-10-01

    Active quality factor (Q) exhibits many promising properties in dynamic atomic force microscopy. Energy dissipation and image contrasts are investigated in the non-contact amplitude modulation atomic force microscopy (AM-AFM) with an active Q-control circuit in the ambient air environment. Dissipated power and virial were calculated to compare the highly nonlinear interaction of tip-sample and image contrasts with different Q gain values. Greater free amplitudes and lower effective Q values show better contrasts for the same setpoint ratio. Active quality factor also can be employed to change tip-sample interaction force in non-contact regime. It is meaningful that non-destructive and better contrast images can be realized in non-contact AM-AFM by applying an active Q-control to the dynamic system.

  9. Internal friction Q factor measurements in lunar rocks

    NASA Technical Reports Server (NTRS)

    Tittmann, B. R.

    1977-01-01

    Investigations to aid in the interpretation of seismic data obtained below the lunar surface are reported. Fine grained basalt with about 1.0% open core porosity was encapsulated under hard vacuum and measured. A Q value just under 2,000 at 0.5 kbar was achieved for a terrestrial analog of lunar basalt. In contrast to the modulus which increases by as much as 10%, the quality factor Q shows little or no change with pressure (a well outgassed sample maintains a high Q, whereas one exposed to laboratory atmosphere maintains a low Q). This result suggests that the absence of volatiles plays an important role in determining the q factor even at a depth of 10 km below the lunar surface.

  10. The advantages of absorbed-dose calibration factors.

    PubMed

    Rogers, D W

    1992-01-01

    A formalism for clinical external beam dosimetry based on use of ion chamber absorbed-dose calibration factors is outlined in the context and notation of the AAPM TG-21 protocol. It is shown that basing clinical dosimetry on absorbed-dose calibration factors ND leads to considerable simplification and reduced uncertainty in dose measurement. In keeping with a protocol which is used in Germany, a quantity kQ is defined which relates an absorbed-dose calibration factor in a beam of quality Q0 to that in a beam of quality Q. For 38 cylindrical ion chambers, two sets of values are presented for ND/NX and Ngas/ND and for kQ for photon beams with beam quality specified by the TPR20(10) ratio. One set is based on TG-21's protocol to allow the new formalism to be used while maintaining equivalence to the TG-21 protocol. To demonstrate the magnitude of the overall error in the TG-21 protocol, the other set uses corrected versions of the TG-21 equations and the more consistent physical data of the IAEA Code of Practice. Comparisons are made to procedures based on air-kerma or exposure calibration factors and it is shown that accuracy and simplicity are gained by avoiding the determination of Ngas from NX. It is also shown that the kQ approach simplifies the use of plastic phantoms in photon beams since kQ values change by less than 0.6% compared to those in water although an overall correction factor of 0.973 is needed to go from absorbed dose in water calibration factors to those in PMMA or polystyrene. Values of kQ calculated using the IAEA Code of Practice are presented but are shown to be anomalous because of the way the effective point of measurement changes for 60Co beams. In photon beams the major difference between the IAEA Code of Practice and the corrected AAPM TG-21 protocol is shown to be the Prepl correction factor. Calculated kQ curves and three parameter equations for them are presented for each wall material and are shown to represent accurately the kQ curve for all ion chambers in this study with a wall of that specified material and a thickness less than 0.25 g/cm2. Values of kQ can be measured using the primary standards for absorbed dose in photon beams.

  11. Ultra-high quality factors in superconducting niobium cavities in ambient magnetic fields up to 190 mG

    DOE PAGES

    Romanenko, A.; Grassellino, A.; Crawford, A. C.; ...

    2014-12-10

    Ambient magnetic field, if trapped in the penetration depth, leads to the residual resistance and therefore sets the limit for the achievable quality factors in superconducting niobium resonators for particle accelerators. Here, we show that a complete expulsion of the magnetic flux can be performed and leads to: (1) record quality factors Q > 2 x 10¹¹ up to accelerating gradient of 22 MV/m; (2) Q ~ 3 x 10¹⁰ at 2 K and 16 MV/m in up to 190 mG magnetic fields. This is achieved by large thermal gradients at the normal/superconducting phase front during the cooldown. Our findingsmore » open up a way to ultra-high quality factors at low temperatures and show an alternative to the sophisticated magnetic shielding implemented in modern superconducting accelerators.« less

  12. Research on Seismic Wave Attenuation in Gas Hydrates Layer Using Vertical Cable Seismic Data

    NASA Astrophysics Data System (ADS)

    Wang, Xiangchun; Liang, Lunhang; Wu, Zhongliang

    2018-06-01

    Vertical cable seismic (VCS) data are the most suitable seismic data for estimating the quality factor Q values of layers under the sea bottom by now. Here the quality factor Q values are estimated using the high-precision logarithmic spectrum ratio method for VCS data. The estimated Q values are applied to identify the layers with gas hydrates and free gas. From the results it can be seen that the Q value in layer with gas hydrates becomes larger and the Q value in layer with free gas becomes smaller than layers without gas hydrates or free gas. Additionally, the estimated Q values are used for inverse Q filtering processing to compensate the attenuated seismic signal's high-frequency component. From the results it can be seen that the main frequency of seismic signal is improved and the frequency band is broadened, the resolution of the VCS data is improved effectively.

  13. Superconducting RF R&D | Technical Division

    Science.gov Websites

    Doping Contact: Anna Grassellino annag High quality factors (Q) are extremely important to accelerators with high duty factor, due to the infrastructure and operating costs of the cryogenic plant. In 2012, a process was discovered at FNAL to achieve unprecedented Q values by treating them in a high temperature

  14. Fabrication of an integrated high-quality-factor (high-Q) optofluidic sensor by femtosecond laser micromachining.

    PubMed

    Song, Jiangxin; Lin, Jintian; Tang, Jialei; Liao, Yang; He, Fei; Wang, Zhaohui; Qiao, Lingling; Sugioka, Koji; Cheng, Ya

    2014-06-16

    We report on fabrication of a microtoroid resonator of a high-quality factor (i.e., Q-factor of ~3.24 × 10(6) measured under the critical coupling condition) integrated in a microfluidic channel using femtosecond laser three-dimensional (3D) micromachining. Coupling of light into and out of the microresonator has been realized with a fiber taper that is reliably assembled with the microtoroid. The assembly of the fiber to the microtoroid is achieved by welding the fiber taper onto the sidewall of the microtoroid using CO2 laser irradiation. The integrated microresonator maintains a high Q-factor of 3.21 × 10(5) as measured in air, which should still be sufficient for many sensing applications. We test the functionality of the integrated optofluidic sensor by performing bulk refractive index sensing of purified water doped with tiny amount of salt. It is shown that a detection limit of ~1.2 × 10(-4) refractive index unit can be achieved. Our result showcases the capability of integration of high-Q microresonators with complex microfluidic systems using femtosecond laser 3D micromachining.

  15. General expressions for the coupling coefficient, quality and filling factors for a cavity with an insert using energy coupled mode theory.

    PubMed

    Elnaggar, Sameh Y; Tervo, Richard; Mattar, Saba M

    2014-05-01

    A cavity (CV) with a dielectric resonator (DR) insert forms an excellent probe for the use in electron paramagnetic resonance (EPR) spectrometers. The probe's coupling coefficient, κ, the quality factor, Q, and the filling factor, η are vital in assessing the EPR spectrometer's performance. Coupled mode theory (CMT) is used to derive general expressions for these parameters. For large permittivity the dominating factor in κ is the ratio of the DR and CV cross sectional areas rather than the dielectric constant. Thus in some cases, resonators with low dielectric constant can couple much stronger with the cavity than do resonators with a high dielectric constant. When the DR and CV frequencies are degenerate, the coupled η is the average of the two uncoupled ones. In practical EPR probes the coupled η is approximately half of that of the DR. The Q of the coupled system generally depends on the eigenvectors, uncoupled frequencies (ω1,ω2) and the individual quality factors (Q1,Q2). It is calculated for different probe configurations and found to agree with the corresponding HFSS® simulations. Provided there is a large difference between the Q1, Q2 pair and the frequencies of DR and CV are degenerate, Q is approximately equal to double the minimum of Q1 and Q2. In general, the signal enhancement ratio, Iwithinsert/Iempty, is obtained from Q and η. For low loss DRs it only depends on η1/η2. However, when the DR has a low Q, the uncoupled Qs are also needed. In EPR spectroscopy it is desirable to excite only a single mode. The separation between the modes, Φ, is calculated as a function of κ and Q. It is found to be significantly greater than five times the average bandwidth. Thus for practical probes, it is possible to excite one of the coupled modes without exciting the other. The CMT expressions derived in this article are quite general and are in excellent agreement with the lumped circuit approach and finite numerical simulations. Hence they can also be applied to a loop-gap resonator in a cavity. For the design effective EPR probes, one needs to consider the κ, Q and η parameters. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. General expressions for the coupling coefficient, quality and filling factors for a cavity with an insert using energy coupled mode theory

    NASA Astrophysics Data System (ADS)

    Elnaggar, Sameh Y.; Tervo, Richard; Mattar, Saba M.

    2014-05-01

    A cavity (CV) with a dielectric resonator (DR) insert forms an excellent probe for the use in electron paramagnetic resonance (EPR) spectrometers. The probe’s coupling coefficient, κ, the quality factor, Q, and the filling factor, η are vital in assessing the EPR spectrometer’s performance. Coupled mode theory (CMT) is used to derive general expressions for these parameters. For large permittivity the dominating factor in κ is the ratio of the DR and CV cross sectional areas rather than the dielectric constant. Thus in some cases, resonators with low dielectric constant can couple much stronger with the cavity than do resonators with a high dielectric constant. When the DR and CV frequencies are degenerate, the coupled η is the average of the two uncoupled ones. In practical EPR probes the coupled η is approximately half of that of the DR. The Q of the coupled system generally depends on the eigenvectors, uncoupled frequencies (ω1, ω2) and the individual quality factors (Q1, Q2). It is calculated for different probe configurations and found to agree with the corresponding HFSS® simulations. Provided there is a large difference between the Q1, Q2 pair and the frequencies of DR and CV are degenerate, Q is approximately equal to double the minimum of Q1 and Q2. In general, the signal enhancement ratio, I/Iempty, is obtained from Q and η. For low loss DRs it only depends on η1/η2. However, when the DR has a low Q, the uncoupled Qs are also needed. In EPR spectroscopy it is desirable to excite only a single mode. The separation between the modes, Φ, is calculated as a function of κ and Q. It is found to be significantly greater than five times the average bandwidth. Thus for practical probes, it is possible to excite one of the coupled modes without exciting the other. The CMT expressions derived in this article are quite general and are in excellent agreement with the lumped circuit approach and finite numerical simulations. Hence they can also be applied to a loop-gap resonator in a cavity. For the design effective EPR probes, one needs to consider the κ, Q and η parameters.

  17. High quality-factor quartz tuning fork glass probe used in tapping mode atomic force microscopy for surface profile measurement

    NASA Astrophysics Data System (ADS)

    Chen, Yuan-Liu; Xu, Yanhao; Shimizu, Yuki; Matsukuma, Hiraku; Gao, Wei

    2018-06-01

    This paper presents a high quality-factor (Q-factor) quartz tuning fork (QTF) with a glass probe attached, used in frequency modulation tapping mode atomic force microscopy (AFM) for the surface profile metrology of micro and nanostructures. Unlike conventionally used QTFs, which have tungsten or platinum probes for tapping mode AFM, and suffer from a low Q-factor influenced by the relatively large mass of the probe, the glass probe, which has a lower density, increases the Q-factor of the QTF probe unit allowing it to obtain better measurement sensitivity. In addition, the process of attaching the probe to the QTF with epoxy resin, which is necessary for tapping mode AFM, is also optimized to further improve the Q-factor of the QTF glass probe. The Q-factor of the optimized QTF glass probe unit is demonstrated to be very close to that of a bare QTF without a probe attached. To verify the effectiveness and the advantages of the optimized QTF glass probe unit, the probe unit is integrated into a home-built tapping mode AFM for conducting surface profile measurements of micro and nanostructures. A blazed grating with fine tool marks of 100 nm, a microprism sheet with a vertical amplitude of 25 µm and a Fresnel lens with a steep slope of 90 degrees are used as measurement specimens. From the measurement results, it is demonstrated that the optimized QTF glass probe unit can achieve higher sensitivity as well as better stability than conventional probes in the measurement of micro and nanostructures.

  18. The resonant body transistor.

    PubMed

    Weinstein, Dana; Bhave, Sunil A

    2010-04-14

    This paper introduces the resonant body transistor (RBT), a silicon-based dielectrically transduced nanoelectromechanical (NEM) resonator embedding a sense transistor directly into the resonator body. Combining the benefits of FET sensing with the frequency scaling capabilities and high quality factors (Q) of internal dielectrically transduced bar resonators, the resonant body transistor achieves >10 GHz frequencies and can be integrated into a standard CMOS process for on-chip clock generation, high-Q microwave circuits, fundamental quantum-state preparation and observation, and high-sensitivity measurements. An 11.7 GHz bulk-mode RBT is demonstrated with a quality factor Q of 1830, marking the highest frequency acoustic resonance measured to date on a silicon wafer.

  19. Extremely Low Loss Phonon-Trapping Cryogenic Acoustic Cavities for Future Physical Experiments

    PubMed Central

    Galliou, Serge; Goryachev, Maxim; Bourquin, Roger; Abbé, Philippe; Aubry, Jean Pierre; Tobar, Michael E.

    2013-01-01

    Low loss Bulk Acoustic Wave devices are considered from the point of view of the solid state approach as phonon-confining cavities. We demonstrate effective design of such acoustic cavities with phonon-trapping techniques exhibiting extremely high quality factors for trapped longitudinally-polarized phonons of various wavelengths. Quality factors of observed modes exceed 1 billion, with a maximum Q-factor of 8 billion and Q × f product of 1.6 · 1018 at liquid helium temperatures. Such high sensitivities allow analysis of intrinsic material losses in resonant phonon systems. Various mechanisms of phonon losses are discussed and estimated. PMID:23823569

  20. SU-E-T-408: Determination of KQ,Q0-Factors From Water and Graphite Calorimetry in a 60 MeV Proton Beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rossomme, S; Renaud, J; Sarfehnia, A

    2014-06-01

    Purpose: To reduce the uncertainty of the beam quality correction factor k Q,Q0, for scattered proton beams (SPB). This factor is used in dosimetry protocols, to determine absorbed dose-to-water with ionization chambers. For the Roos plane parallel chambers (RPPICs), the IAEA TRS-398 protocol estimates k Q,Q0-factor to be 1.004(for a beam quality Rres=2 g.cm{sup 2}), with an uncertainty of 2.1%. Methods: A graphite calorimeter (GCal), a water calorimeter (WCal) and RPPICs were exposed, in a single experiment, to a 60 MeV non-modulated SPB. RPPICs were calibrated in terms of absorbed dose-to-water in a 20 MeV electron beam. The calibration coefficientmore » is traceable to NPL's absorbed dose standards. Chamber measurements were corrected for environmental conditions, recombination and polarity. The WCal corrections include heat loss, heat defect and vessel perturbation. The GCal corrections include heat loss and absorbed dose conversion. Except for heat loss correction and its uncertainty in the WCal system, all major corrections were included in the analysis. Other minor corrections, such as beam profile non-uniformity, are still to be evaluated. Experimental k Q,Q0-factors were derived by comparing the results obtained with both calorimeters and ionometry. Results: The absorbed dose-to-water from both calorimeters was found to be within 1.3% with an uncertainty of 1.2%. k Q,Q0-factor for a RPPIC was found to be 0.998 and 1.011, with a standard uncertainty of 1.4% and 0.9% when the dose is based on the GCal and the WCal, respectively. Conclusion: Results suggest the possibility to determine k Q,Q0-values for PPICs in SPB with a lower uncertainty than specified in the TRS-398 thereby helping to reduce uncertainty on absorbed dose-to-water. The agreement between calorimeters confirms the possibility to use GCal or WCal as primary standard in SPB. Because of the dose conversion, the use of GCal may lead to slightly higher uncertainty, but is, at present, considerably easier to operate.« less

  1. Measured and Monte Carlo calculated k{sub Q} factors: Accuracy and comparison

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muir, B. R.; McEwen, M. R.; Rogers, D. W. O.

    2011-08-15

    Purpose: The journal Medical Physics recently published two papers that determine beam quality conversion factors, k{sub Q}, for large sets of ion chambers. In the first paper [McEwen Med. Phys. 37, 2179-2193 (2010)], k{sub Q} was determined experimentally, while the second paper [Muir and Rogers Med. Phys. 37, 5939-5950 (2010)] provides k{sub Q} factors calculated using Monte Carlo simulations. This work investigates a variety of additional consistency checks to verify the accuracy of the k{sub Q} factors determined in each publication and a comparison of the two data sets. Uncertainty introduced in calculated k{sub Q} factors by possible variation ofmore » W/e with beam energy is investigated further. Methods: The validity of the experimental set of k{sub Q} factors relies on the accuracy of the NE2571 reference chamber measurements to which k{sub Q} factors for all other ion chambers are correlated. The stability of NE2571 absorbed dose to water calibration coefficients is determined and comparison to other experimental k{sub Q} factors is analyzed. Reliability of Monte Carlo calculated k{sub Q} factors is assessed through comparison to other publications that provide Monte Carlo calculations of k{sub Q} as well as an analysis of the sleeve effect, the effect of cavity length and self-consistencies between graphite-walled Farmer-chambers. Comparison between the two data sets is given in terms of the percent difference between the k{sub Q} factors presented in both publications. Results: Monitoring of the absorbed dose calibration coefficients for the NE2571 chambers over a period of more than 15 yrs exhibit consistency at a level better than 0.1%. Agreement of the NE2571 k{sub Q} factors with a quadratic fit to all other experimental data from standards labs for the same chamber is observed within 0.3%. Monte Carlo calculated k{sub Q} factors are in good agreement with most other Monte Carlo calculated k{sub Q} factors. Expected results are observed for the sleeve effect and the effect of cavity length on k{sub Q}. The mean percent differences between experimental and Monte Carlo calculated k{sub Q} factors are -0.08, -0.07, and -0.23% for the Elekta 6, 10, and 25 MV nominal beam energies, respectively. An upper limit on the variation of W/e in photon beams from cobalt-60 to 25 MV is determined as 0.4% with 95% confidence. The combined uncertainty on Monte Carlo calculated k{sub Q} factors is reassessed and amounts to between 0.40 and 0.49% depending on the wall material of the chamber. Conclusions: Excellent agreement (mean percent difference of only 0.13% for the entire data set) between experimental and calculated k{sub Q} factors is observed. For some chambers, k{sub Q} is measured for only one chamber of each type--the level of agreement observed in this study would suggest that for those chambers the measured k{sub Q} values are generally representative of the chamber type.« less

  2. Dosimetry for Small and Nonstandard Fields

    NASA Astrophysics Data System (ADS)

    Junell, Stephanie L.

    The proposed small and non-standard field dosimetry protocol from the joint International Atomic Energy Agency (IAEA) and American Association of Physicist in Medicine working group introduces new reference field conditions for ionization chamber based reference dosimetry. Absorbed dose beam quality conversion factors (kQ factors) corresponding to this formalism were determined for three different models of ionization chambers: a Farmer-type ionization chamber, a thimble ionization chamber, and a small volume ionization chamber. Beam quality correction factor measurements were made in a specially developed cylindrical polymethyl methacrylate (PMMA) phantom and a water phantom using thermoluminescent dosimeters (TLDs) and alanine dosimeters to determine dose to water. The TLD system for absorbed dose to water determination in high energy photon and electron beams was fully characterized as part of this dissertation. The behavior of the beam quality correction factor was observed as it transfers the calibration coefficient from the University of Wisconsin Accredited Dosimetry Calibration Laboratory (UWADCL) 60Co reference beam to the small field calibration conditions of the small field formalism. TLD-determined beam quality correction factors for the calibration conditions investigated ranged from 0.97 to 1.30 and had associated standard deviations from 1% to 3%. The alanine-determined beam quality correction factors ranged from 0.996 to 1.293. Volume averaging effects were observed with the Farmer-type ionization chamber in the small static field conditions. The proposed small and non-standard field dosimetry protocols new composite-field reference condition demonstrated its potential to reduce or remove ionization chamber volume dependancies, but the measured beam quality correction factors were not equal to the standard CoP's kQ, indicating a change in beam quality in the small and non-standard field dosimetry protocols new composite-field reference condition relative to the standard broad beam reference conditions. The TLD- and alanine-determined beam quality correction factors in the composite-field reference conditions were approximately 3% greater and differed by more than one standard deviation from the published TG-51 kQ values for all three chambers.

  3. Empirical evaluation of humpback whale telomere length estimates; quality control and factors causing variability in the singleplex and multiplex qPCR methods.

    PubMed

    Olsen, Morten Tange; Bérubé, Martine; Robbins, Jooke; Palsbøll, Per J

    2012-09-06

    Telomeres, the protective cap of chromosomes, have emerged as powerful markers of biological age and life history in model and non-model species. The qPCR method for telomere length estimation is one of the most common methods for telomere length estimation, but has received recent critique for being too error-prone and yielding unreliable results. This critique coincides with an increasing awareness of the potentials and limitations of the qPCR technique in general and the proposal of a general set of guidelines (MIQE) for standardization of experimental, analytical, and reporting steps of qPCR. In order to evaluate the utility of the qPCR method for telomere length estimation in non-model species, we carried out four different qPCR assays directed at humpback whale telomeres, and subsequently performed a rigorous quality control to evaluate the performance of each assay. Performance differed substantially among assays and only one assay was found useful for telomere length estimation in humpback whales. The most notable factors causing these inter-assay differences were primer design and choice of using singleplex or multiplex assays. Inferred amplification efficiencies differed by up to 40% depending on assay and quantification method, however this variation only affected telomere length estimates in the worst performing assays. Our results suggest that seemingly well performing qPCR assays may contain biases that will only be detected by extensive quality control. Moreover, we show that the qPCR method for telomere length estimation can be highly precise and accurate, and thus suitable for telomere measurement in non-model species, if effort is devoted to optimization at all experimental and analytical steps. We conclude by highlighting a set of quality controls which may serve for further standardization of the qPCR method for telomere length estimation, and discuss some of the factors that may cause variation in qPCR experiments.

  4. Empirical evaluation of humpback whale telomere length estimates; quality control and factors causing variability in the singleplex and multiplex qPCR methods

    PubMed Central

    2012-01-01

    Background Telomeres, the protective cap of chromosomes, have emerged as powerful markers of biological age and life history in model and non-model species. The qPCR method for telomere length estimation is one of the most common methods for telomere length estimation, but has received recent critique for being too error-prone and yielding unreliable results. This critique coincides with an increasing awareness of the potentials and limitations of the qPCR technique in general and the proposal of a general set of guidelines (MIQE) for standardization of experimental, analytical, and reporting steps of qPCR. In order to evaluate the utility of the qPCR method for telomere length estimation in non-model species, we carried out four different qPCR assays directed at humpback whale telomeres, and subsequently performed a rigorous quality control to evaluate the performance of each assay. Results Performance differed substantially among assays and only one assay was found useful for telomere length estimation in humpback whales. The most notable factors causing these inter-assay differences were primer design and choice of using singleplex or multiplex assays. Inferred amplification efficiencies differed by up to 40% depending on assay and quantification method, however this variation only affected telomere length estimates in the worst performing assays. Conclusion Our results suggest that seemingly well performing qPCR assays may contain biases that will only be detected by extensive quality control. Moreover, we show that the qPCR method for telomere length estimation can be highly precise and accurate, and thus suitable for telomere measurement in non-model species, if effort is devoted to optimization at all experimental and analytical steps. We conclude by highlighting a set of quality controls which may serve for further standardization of the qPCR method for telomere length estimation, and discuss some of the factors that may cause variation in qPCR experiments. PMID:22954451

  5. The combination of high Q factor and chirality in twin cavities and microcavity chain

    PubMed Central

    Song, Qinghai; Zhang, Nan; Zhai, Huilin; Liu, Shuai; Gu, Zhiyuan; Wang, Kaiyang; Sun, Shang; Chen, Zhiwei; Li, Meng; Xiao, Shumin

    2014-01-01

    Chirality in microcavities has recently shown its bright future in optical sensing and microsized coherent light sources. The key parameters for such applications are the high quality (Q) factor and large chirality. However, the previous reported chiral resonances are either low Q modes or require very special cavity designs. Here we demonstrate a novel, robust, and general mechanism to obtain the chirality in circular cavity. By placing a circular cavity and a spiral cavity in proximity, we show that ultra-high Q factor, large chirality, and unidirectional output can be obtained simultaneously. The highest Q factors of the non-orthogonal mode pairs are almost the same as the ones in circular cavity. And the co-propagating directions of the non-orthogonal mode pairs can be reversed by tuning the mode coupling. This new mechanism for the combination of high Q factor and large chirality is found to be very robust to cavity size, refractive index, and the shape deformation, showing very nice fabrication tolerance. And it can be further extended to microcavity chain and microcavity plane. We believe that our research will shed light on the practical applications of chirality and microcavities. PMID:25262881

  6. Ultra-wideband microwave photonic filter with a high Q-factor using a semiconductor optical amplifier.

    PubMed

    Chen, Han

    2017-04-01

    An ultra-wideband microwave photonic filter (MPF) with a high quality (Q)-factor based on the birefringence effects in a semiconductor optical amplifier (SOA) is presented, and the theoretical fundamentals of the design are explained. The proposed MPF along orthogonal polarization in an active loop operates at up to a Ku-band and provides a tunable free spectral range from 15.44 to 19.44 GHz by controlling the SOA injection current. A prototype of the equivalent second-order infinite impulse response filter with a Q-factor over 6300 and a rejection ration exceeding 41 dB is experimentally demonstrated.

  7. High field Q slope and the effect of low-temperature baking at 3 GHz

    NASA Astrophysics Data System (ADS)

    Ciovati, G.; Eremeev, G.; Hannon, F.

    2018-01-01

    A strong degradation of the unloaded quality factor with field, called high field Q slope, is commonly observed above Bp ≅100 mT in elliptical superconducting niobium cavities at 1.3 and 1.5 GHz. In the present experiments several 3 GHz niobium cavities were measured up to and above Bp ≅100 mT . The measurements show that a high field Q slope phenomenon limits the field reach at this frequency, that the high field Q slope onset field depends weakly on the frequency, and that the high field Q slope can be removed by the typical empirical solution of electropolishing followed by heating to 120°C for 48 hrs. In addition, one of the cavities reached a quench field of 174 mT and its field dependence of the quality factor was compared against global heating predicted by a thermal feedback model.

  8. Ultra-High Q Acoustic Resonance in Superfluid ^4He

    NASA Astrophysics Data System (ADS)

    De Lorenzo, L. A.; Schwab, K. C.

    2017-02-01

    We report the measurement of the acoustic quality factor of a gram-scale, kilohertz-frequency superfluid resonator, detected through the parametric coupling to a superconducting niobium microwave cavity. For temperatures between 400 mK and 50 mK, we observe a T^{-4} temperature dependence of the quality factor, consistent with a 3-phonon dissipation mechanism. We observe Q factors up to 1.4× 10^8, consistent with the dissipation due to dilute ^3He impurities, and expect that significant further improvements are possible. These experiments are relevant to exploring quantum behavior and decoherence of massive macroscopic objects, the laboratory detection of continuous gravitational waves from pulsars, and the probing of possible limits to physical length scales.

  9. DOSIMETRIC response of a REM-500 in low energy neutron fields typical of nuclear power plants.

    PubMed

    Aslam; Matysiak, W; Atanackovic, J; Waker, A J

    2012-06-01

    This study investigates the response of a REM-500 to assess neutron quality factor and dose equivalent in low energy neutron fields, which are commonly encountered in the workplace environment of nuclear power stations. The McMaster University 3 MV Van de Graaff accelerator facility was used to measure the response of the instrument in monoenergetic neutron fields in the energy range 51 to 727 keV by bombarding a thin LiF target with 1.93-2.50 MeV protons. The energy distribution of the neutron fields produced in the facility was measured by a (3)He filled gas ionization chamber. The MCA mode of the REM-500 instrument was used to collect lineal energy distributions at varying neutron energies and to calculate the frequency and dose-mean lineal energies. The effective quality factor, Q-, was also calculated using the values of Q(y)listed in the REM-500 operation manual and compared with those of ICRP 60. The authors observed a continuously increasing trend in y - F, y-D, and Q-with an increase in neutron energy. It is interesting to note that standard tissue equivalent proportional counters (TEPCs) filled with tissue equivalent(TE) gas give rise to a similar trend for these microdosimetric quantities of interest in the same energy range; however, the averages calculated in this study are larger by about 15%compared to a TEPC filled with propane-based TE gas probably because of the larger stopping power of protons in propane compared to TE gas. These somewhat larger event sizes did not result in any significant increase in the Q-compared to those obtained from a TEPC filled with TE gas and were found to be in good agreement with other measurements reported earlier at corresponding neutron energies. The instrument quality factor response, R(Q), defined as the ratio of measured quality factor to the calculated quality factor in an ICRU tissue sphere,was found to vary with neutron energy. The instrument response,R(Q), was ~0.6 at 727 keV, which deteriorates further to ~0.3 at 51 keV neutron energy. The counter response based on ICRP 60 was comparable to an ideal response of 1.0 above 600 keV, which dropped to ~0.8 at 159 keV and ~0.4 at 51 keV neutron energy. The decline in counter quality factor response based on ICRP 60 was found to be much steeper than that when using the instrument’s built-in function for quality factor.The REM-500 measures a dose equivalent at 727 keV,which is 60% of the ambient dose equivalent, 40% at 159 keV,and 15% at 51 keV. Two algorithms have been developed, one for real time measurement and another to be used post measurement,and their efficacy is demonstrated in determining the quality factor and the ambient dose equivalent in low energy neutron fields, which are typical for the workplace environment in CANDU® nuclear power generating stations.

  10. Mid-infrared ultra-high-Q resonators based on fluoride crystalline materials

    NASA Astrophysics Data System (ADS)

    Lecaplain, C.; Javerzac-Galy, C.; Gorodetsky, M. L.; Kippenberg, T. J.

    2016-11-01

    The unavailability of highly transparent materials in the mid-infrared has been the main limitation in the development of ultra-sensitive molecular sensors or cavity-based spectroscopy applications. Whispering gallery mode microresonators have attained ultra-high-quality (Q) factor resonances in the near-infrared and visible. Here we report ultra-high Q factors in the mid-infrared using polished alkaline earth metal fluoride crystals. Using an uncoated chalcogenide tapered fibre as a high-ideality coupler in the mid-infrared, we study via cavity ringdown technique the losses of BaF2, CaF2, MgF2 and SrF2 microresonators. We show that MgF2 is limited by multiphonon absorption by studying the temperature dependence of the Q factor. In contrast, in SrF2 and BaF2 the lower multiphonon absorption leads to ultra-high Q factors at 4.5 μm. These values correspond to an optical finesse of , the highest value achieved for any type of mid-infrared resonator to date.

  11. Mid-infrared ultra-high-Q resonators based on fluoride crystalline materials

    PubMed Central

    Lecaplain, C.; Javerzac-Galy, C.; Gorodetsky, M. L.; Kippenberg, T. J.

    2016-01-01

    The unavailability of highly transparent materials in the mid-infrared has been the main limitation in the development of ultra-sensitive molecular sensors or cavity-based spectroscopy applications. Whispering gallery mode microresonators have attained ultra-high-quality (Q) factor resonances in the near-infrared and visible. Here we report ultra-high Q factors in the mid-infrared using polished alkaline earth metal fluoride crystals. Using an uncoated chalcogenide tapered fibre as a high-ideality coupler in the mid-infrared, we study via cavity ringdown technique the losses of BaF2, CaF2, MgF2 and SrF2 microresonators. We show that MgF2 is limited by multiphonon absorption by studying the temperature dependence of the Q factor. In contrast, in SrF2 and BaF2 the lower multiphonon absorption leads to ultra-high Q factors at 4.5 μm. These values correspond to an optical finesse of , the highest value achieved for any type of mid-infrared resonator to date. PMID:27869119

  12. Mid-infrared ultra-high-Q resonators based on fluoride crystalline materials.

    PubMed

    Lecaplain, C; Javerzac-Galy, C; Gorodetsky, M L; Kippenberg, T J

    2016-11-21

    The unavailability of highly transparent materials in the mid-infrared has been the main limitation in the development of ultra-sensitive molecular sensors or cavity-based spectroscopy applications. Whispering gallery mode microresonators have attained ultra-high-quality (Q) factor resonances in the near-infrared and visible. Here we report ultra-high Q factors in the mid-infrared using polished alkaline earth metal fluoride crystals. Using an uncoated chalcogenide tapered fibre as a high-ideality coupler in the mid-infrared, we study via cavity ringdown technique the losses of BaF 2 , CaF 2 , MgF 2 and SrF 2 microresonators. We show that MgF 2 is limited by multiphonon absorption by studying the temperature dependence of the Q factor. In contrast, in SrF 2 and BaF 2 the lower multiphonon absorption leads to ultra-high Q factors at 4.5 μm. These values correspond to an optical finesse of , the highest value achieved for any type of mid-infrared resonator to date.

  13. Psychometric properties of the Belgian coach version of the coach-athlete relationship questionnaire (CART-Q).

    PubMed

    Balduck, A-L; Jowett, S

    2010-10-01

    The study examined the psychometric properties of the Belgian coach version of the Coach-Athlete Relationship Questionnaire (CART-Q). The questionnaire includes three dimensions (Closeness, Commitment, and Complementarity) in a model that intends to measure the quality of the coach-athlete relationship. Belgian coaches (n=144) of athletes who performed at various competition levels in such sports as football, basketball, and volleyball responded to the CART-Q and to the Leadership Scale for Sport (LSS). A confirmatory factor analysis proved to be slightly more satisfactory for a three-order factor model, compared with a hierarchical first-order factor model. The three factors showed acceptable internal consistency scores. Moreover, functional associations between the three factors and coach leadership behaviors were found offering support to the instrument's concurrent validity. The findings support previous validation studies and verify the psychometric properties of the CART-Q applied to Belgian coaches of team sports. © 2009 John Wiley & Sons A/S.

  14. On the impact of ICRU report 90 recommendations on kQ factors for high-energy photon beams.

    PubMed

    Mainegra-Hing, Ernesto; Muir, Bryan R

    2018-06-03

    To assess the impact of the ICRU report 90 recommendations on the beam-quality conversion factor, k Q , used for clinical reference dosimetry of megavoltage linac photon beams. The absorbed dose to water and the absorbed dose to the air in ionization chambers representative of those typically used for linac photon reference dosimetry are calculated at the reference depth in a water phantom using Monte Carlo simulations. Depth-dose calculations in water are also performed to investigate changes in beam quality specifiers. The calculations are performed in a cobalt-60 beam and MV photon beams with nominal energy between 6 MV and 25 MV using the EGSnrc simulation toolkit. Inputs to the calculations use stopping-power data for graphite and water from the original ICRU-37 report and the new proposed values from the recently published ICRU-90 report. Calculated k Q factors are compared using the two different recommendations for key dosimetry data and measured k Q factors. Less than about 0.1% effects from ICRU-90 recommendations on the beam quality specifiers, the photon component of the percentage depth-dose at 10 cm, %dd(10) x , and the tissue-phantom ratio at 20 cm and 10 cm, TPR1020, are observed. Although using different recommendations for key dosimetric data impact water-to-air stopping-power ratios and ion chamber perturbation corrections by up to 0.54% and 0.40%, respectively, we observe little difference (≤0.14%) in calculated k Q factors. This is contradictory to the predictions in ICRU-90 that suggest differences up to 0.5% in high-energy photon beams. A slightly better agreement with experimental values is obtained when using ICRU-90 recommendations. Users of the addendum to the TG-51 protocol for reference dosimetry of high-energy photon beams, which recommends Monte Carlo calculated k Q factors, can rest assured that the recommendations of ICRU report 90 on basic data have little impact on this central dosimetric parameter. © Her Majesty the Queen in Right of Canada 2018. Reproduced with the permission of the Minister of Science.

  15. The Negative Correlation between Fiber Color and Quality Traits Revealed by QTL Analysis.

    PubMed

    Feng, Hongjie; Guo, Lixue; Wang, Gaskin; Sun, Junling; Pan, Zhaoe; He, Shoupu; Zhu, Heqin; Sun, Jie; Du, Xiongming

    2015-01-01

    Naturally existing colored cotton was far from perfection due to having genetic factors for lower yield, poor fiber quality and monotonous color. These factors posed a challenge to colored cotton breeding and innovation. To identify novel quantitative trait loci (QTL) for fiber color along with understanding of correlation between fiber color and quality in colored cotton, a RIL and two F2 populations were generated from crosses among Zong128 (Brown fiber cotton) and two white fiber cotton lines which were then analyzed in four environments. Two stable and major QTLs (qLC-7-1, qFC-7-1) for fiber lint and fuzz color were detected accounting for 16.01%-59.85% of the phenotypic variation across multiple generations and environments. Meanwhile, some minor QTLs were also identified on chromosomes 5, 14, 21 and 24 providing low phenotypic variation (<5%) from only F2 populations, not from the RILs population. Especially, a multiple-effect locus for fiber color and quality has been detected between flanking markers NAU1043 and NAU3654 on chromosome 7 (A genome) over multiple environments. Of which, qLC-7-1, qFC-7-1 were responsible for positive effects and improved fiber color in offsprings. Meanwhile, the QTLs (qFL-7-1, qFU-7-1, qFF-7-1, qFE-7-1, and qFS-7-1) for fiber quality had negative effects and explained 2.19%-8.78% of the phenotypic variation. This multiple-effect locus for fiber color and quality may reveal the negative correlation between the two types of above traits, so paving the way towards cotton genetic improvement.

  16. Monte Carlo calculations of k{sub Q}, the beam quality conversion factor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muir, B. R.; Rogers, D. W. O.

    2010-11-15

    Purpose: To use EGSnrc Monte Carlo simulations to directly calculate beam quality conversion factors, k{sub Q}, for 32 cylindrical ionization chambers over a range of beam qualities and to quantify the effect of systematic uncertainties on Monte Carlo calculations of k{sub Q}. These factors are required to use the TG-51 or TRS-398 clinical dosimetry protocols for calibrating external radiotherapy beams. Methods: Ionization chambers are modeled either from blueprints or manufacturers' user's manuals. The dose-to-air in the chamber is calculated using the EGSnrc user-code egs{sub c}hamber using 11 different tabulated clinical photon spectra for the incident beams. The dose to amore » small volume of water is also calculated in the absence of the chamber at the midpoint of the chamber on its central axis. Using a simple equation, k{sub Q} is calculated from these quantities under the assumption that W/e is constant with energy and compared to TG-51 protocol and measured values. Results: Polynomial fits to the Monte Carlo calculated k{sub Q} factors as a function of beam quality expressed as %dd(10){sub x} and TPR{sub 10}{sup 20} are given for each ionization chamber. Differences are explained between Monte Carlo calculated values and values from the TG-51 protocol or calculated using the computer program used for TG-51 calculations. Systematic uncertainties in calculated k{sub Q} values are analyzed and amount to a maximum of one standard deviation uncertainty of 0.99% if one assumes that photon cross-section uncertainties are uncorrelated and 0.63% if they are assumed correlated. The largest components of the uncertainty are the constancy of W/e and the uncertainty in the cross-section for photons in water. Conclusions: It is now possible to calculate k{sub Q} directly using Monte Carlo simulations. Monte Carlo calculations for most ionization chambers give results which are comparable to TG-51 values. Discrepancies can be explained using individual Monte Carlo calculations of various correction factors which are more accurate than previously used values. For small ionization chambers with central electrodes composed of high-Z materials, the effect of the central electrode is much larger than that for the aluminum electrodes in Farmer chambers.« less

  17. Recent progress in opto-electronic oscillator

    NASA Technical Reports Server (NTRS)

    Maleki, Lute

    2005-01-01

    The optoelectronic oscillator (OEO) is a unique device based on photonics techniques to generate highly spectrally pure microwave signals [1]. The development of the OEO was motivated by the need for high performance oscillators in the frequency range larger than 10 GHz, where conventional electronic oscillators have a number of limitations. These limitations typically stem from the product of fQ, where f is the oscillator frequency and Q is the quality factor of the resonator in the oscillator. In conventional resonators, whether electromagnetic or piezoelectric, this product is usually a constant. Thus, as the oscillator frequency is pushed higher, the quality factor degrades, resulting in degradation of the phase noise of the oscillator. An approach to mitigate the problem is to start with a very high quality signal in the 5 to 100 MHz range generated by a quartz oscillator and multiply the frequency to achieve the desired microwave signal. Here again, frequency multiplication also results in an increase of the phase noise by a factor of 2010gN, where N is the multiplication factor.

  18. Tunable Q-Factor RF Cavity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Balcazar, Mario D.; Yonehara, Katsuya; Moretti, Alfred

    Intense neutrino beam is a unique probe for researching beyond the standard model. Fermilab is the main institution to produce the most powerful and widespectrum neutrino beam. From that respective, a radiation robust beam diagnostic system is a critical element in order to maintain the quality of the neutrino beam. Within this context, a novel radiation-resistive beam profile monitor based on a gasfilled RF cavity is proposed. The goal of this measurement is to study a tunable Qfactor RF cavity to determine the accuracy of the RF signal as a function of the quality factor. Specifically, measurement error of themore » Q-factor in the RF calibration is investigated. Then, the RF system will be improved to minimize signal error.« less

  19. Soliton all-optical logic AND gate with semiconductor optical amplifier-assisted Mach-Zehnder interferometer

    NASA Astrophysics Data System (ADS)

    Kotb, Amer; Zoiros, Kyriakos E.

    2016-08-01

    The concept of soliton provides a line in research in telecommunications systems. In the present study, a soliton all-optical logic AND gate with semiconductor optical amplifier (SOA)-assisted Mach-Zehnder interferometer has been numerically simulated and investigated. The dependence of the output quality factor (Q-factor) on the soliton characteristics and SOA parameters has been examined and assessed. The obtained results demonstrate that the soliton AND gate is capable of operating at a data rate of 80 Gb/s with logical correctness and high-output Q-factor.

  20. Significant improvement in the thermal annealing process of optical resonators

    NASA Astrophysics Data System (ADS)

    Salzenstein, Patrice; Zarubin, Mikhail

    2017-05-01

    Thermal annealing performed during process improves the quality of the roughness of optical resonators reducing stresses at the periphery of their surface thus allowing higher Q-factors. After a preliminary realization, the design of the oven and the electronic method were significantly improved thanks to nichrome resistant alloy wires and chopped basalt fibers for thermal isolation during the annealing process. Q-factors can then be improved.

  1. Factor Structure of the Schalock and Keith Quality of Life Questionnaire (QOL-Q): Validation on Mexican and Spanish Samples

    ERIC Educational Resources Information Center

    Caballo, C.; Crespo, M.; Jenaro, C.; Verdugo, M. A.; Martinez, J. L.

    2005-01-01

    Background: The Quality of Life Questionnaire (QOL-Q) is used widely to evaluate the quality of life of persons with intellectual disability (ID). Its validity for use with Spanish-speaking cultures has been demonstrated for individuals with visual disabilities, but not for those with physical or intellectual disabilities. Such was the purpose of…

  2. Effects of Aperture Size on Q factor and Shielding Effectiveness of a Cubic Resonator

    NASA Astrophysics Data System (ADS)

    Parr, Stefan; Chromy, Stephan; Dickmann, Stefan; Schaarschmidt, Martin

    2017-09-01

    The EMC properties of a cubic metallic shield are highly affected by its resonances. At the resonant frequencies, the shielding effectiveness (SE) collapses, which results in high field strengths inside the cavity. This can cause failure or even breakdown of electronic devices inside the shield. The resonant behaviour is mainly determined by the quality or Q factor of the shield. In this paper, the effects of the aperture size on the Q factor and the SE of an electrically large, cubic shield are analysed. At first, a method is developed in order to determine the Q factor based on the resonance behaviour of the shield in time domain. Only the first resonance of the shield is considered therefore. The results are evaluated for different aperture diameters and compared with theory for the Q factor. The dominant coupling mechanism of electromagnetic energy into the shield is thus identified. Then the effect of aperture size on the SE is analysed. The excitation of resonances is very probable if the interfering signal is an ultrawideband (UWB) pulse, which constitutes a typical intentional electromagnetic interference (IEMI) scenario. Therefore, the relation between aperture size and SE is analysed using the theory of the transient SE for a broadband signal with a constant spectral density distribution. The results show, that a worst case aperture size exists, where the SE has its minimum.

  3. Weighting factors for radiation quality: how to unite the two current concepts.

    PubMed

    Kellerer, Albrecht M

    2004-01-01

    The quality factor, Q(L), used to be the universal weighting factor to account for radiation quality, until--in its 1991 Recommendations--the ICRP established a dichotomy between 'computable' and 'measurable' quantities. The new concept of the radiation weighting factor, w(R), was introduced for use with the 'computable' quantities, such as the effective dose, E. At the same time, the application of Q(L) was restricted to 'measurable' quantities, such as the operational quantities ambient dose equivalent or personal dose equivalent. The result has been a dual system of incoherent dosimetric quantities. The most conspicuous inconsistency resulted for neutrons, for which the new concept of wR had been primarily designed. While its definition requires an accounting for the gamma rays produced by neutron capture in the human body, this effect is not adequately reflected in the numerical values of wR, which are now suitable for mice, but are--at energies of the incident neutrons below 1 MeV--conspicuously too large for man. A recent Report 92 to ICRP has developed a proposal to correct the current imbalance and to define a linkage between the concepts Q(L) and wR. The proposal is here considered within a broader assessment of the rationale that led to the current dual system of dosimetric quantities.

  4. High field Q slope and the effect of low-temperature baking at 3 GHz

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ciovati, G.; Eremeev, G.; Hannon, F.

    Here, a strong degradation of the unloaded quality factor with field, called high field Q-slope, is commonly observed above Bmore » $$_{p}$$ $$\\cong$$ 100 mT in elliptical superconducting niobium cavities at 1.3 GHz and 1.5 GHz. In the present experiments several 3 GHz niobium cavities were measured up to and above B$$_{p}$$ $$\\cong$$100 mT. The measurements show that a high field Q-slope phenomenon limits the field reach at this frequency, that the high field Q-slope onset field depends weakly on the frequency, and that the high field Q-slope can be removed by the typical empirical solution of electropolishing followed by heating to 120 $$^{\\circ}$$C for 48 hrs. In addition, one of the cavities reached a quench field of 174~mT and its field dependence of the quality factor was compared against global heating predicted by a thermal feedback model.« less

  5. High field Q slope and the effect of low-temperature baking at 3 GHz

    DOE PAGES

    Ciovati, G.; Eremeev, G.; Hannon, F.

    2018-01-29

    Here, a strong degradation of the unloaded quality factor with field, called high field Q-slope, is commonly observed above Bmore » $$_{p}$$ $$\\cong$$ 100 mT in elliptical superconducting niobium cavities at 1.3 GHz and 1.5 GHz. In the present experiments several 3 GHz niobium cavities were measured up to and above B$$_{p}$$ $$\\cong$$100 mT. The measurements show that a high field Q-slope phenomenon limits the field reach at this frequency, that the high field Q-slope onset field depends weakly on the frequency, and that the high field Q-slope can be removed by the typical empirical solution of electropolishing followed by heating to 120 $$^{\\circ}$$C for 48 hrs. In addition, one of the cavities reached a quench field of 174~mT and its field dependence of the quality factor was compared against global heating predicted by a thermal feedback model.« less

  6. Healthful dietary patterns and long-term weight change among women with a history of gestational diabetes mellitus.

    PubMed

    Tobias, D K; Zhang, C; Chavarro, J; Olsen, S; Bao, W; Bjerregaard, A A; Fung, T T; Manson, J E; Hu, F B

    2016-11-01

    Diet represents a key strategy for the prevention of obesity and type 2 diabetes among women with a history of gestational diabetes mellitus (GDM), although effective dietary patterns to prevent weight gain in the long term are largely unknown. We sought to evaluate whether improvement in overall diet quality is associated with less long-term weight gain among high-risk women with prior GDM. Women with a history of GDM (N=3397) were followed from 1991 to 2011, or until diagnosis of type 2 diabetes or other chronic disease. Usual diet was assessed via food frequency questionnaire every 4 years from which we calculated the Alternative Healthy Eating Index (aHEI-2010), Alternate Mediterranean Diet (AMED) and Dietary Approaches to Stop Hypertension (DASH) dietary pattern scores. Weight, lifestyle and health-related outcomes were self-reported every 2 years. We estimated the change in dietary score with change in body weight using linear regression models adjusting for age, baseline body mass index (BMI), baseline and simultaneous change in physical activity and smoking status and other risk factors. Women were followed up to 20 years, gaining an average 1.9 kg (s.d.=7.0) per 4-year period. Women in the highest quintile (Q5) of diet change (most improvement in quality) gained significantly less weight per 4-year period than the lowest quintile (Q1; decrease in quality), independent of other risk factors (4-year weight change, aHEI-2010: Q5=1.30 kg vs Q1=3.27 kg; AMED: Q5=0.94 kg vs Q1=2.56 kg, DASH: Q5=0.64 kg vs Q1=2.75 kg). Significant effect modification by BMI (p-interactions <0.001) indicated a greater magnitude of weight change among women with a higher baseline BMI for all three patterns. Increased diet quality was associated with less weight gain, independent of other lifestyle factors. Post-partum recommendations on diet quality may provide one strategy to prevent long-term weight gain in this high-risk group.

  7. Laser Vision Correction with Q Factor Modification for Keratoconus Management.

    PubMed

    Pahuja, Natasha Kishore; Shetty, Rohit; Sinha Roy, Abhijit; Thakkar, Maithil Mukesh; Jayadev, Chaitra; Nuijts, Rudy Mma; Nagaraja, Harsha

    2017-04-01

    To evaluate the outcomes of corneal laser ablation with Q factor modification for vision correction in patients with progressive keratoconus. In this prospective study, 50 eyes of 50 patients were divided into two groups based on Q factor (>-1 in Group I and ≤-1 in Group II). All patients underwent a detailed ophthalmic examination including uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), subjective acceptance and corneal topography using the Pentacam. The topolyzer was used to measure the corneal asphericity (Q). Ablation was performed based on the preoperative Q values and thinnest pachymetry to obtain a target of near normal Q. This was followed by corneal collagen crosslinking to stabilize the progression. Statistically significant improvement (p ≤ 0.05) was noticed in refractive, topographic, and Q values posttreatment in both groups. The improvement in higher-order aberrations and total aberrations were statistically significant in both groups; however, the spherical aberration showed statistically significant improvement only in Group II. Ablation based on the preoperative Q and pachymetry for a near normal postoperative Q value appears to be an effective method to improve the visual acuity and quality in patients with keratoconus.

  8. Internal friction quality-factor Q under confining pressure. [of lunar rocks

    NASA Technical Reports Server (NTRS)

    Tittmann, B. R.; Ahlberg, L.; Nadler, H.; Curnow, J.; Smith, T.; Cohen, E. R.

    1977-01-01

    It has been found in previous studies that small amounts of adsorbed volatiles can have a profound effect on the internal friction quality-factor Q of rocks and other porous media. Pandit and Tozer (1970) have suggested that the laboratory-measured Q of volatile-free rocks should be similar to the in situ seismic Q values of near-surface lunar rocks which according to Latham et al. (1970) are in the range of 3000-5000. Observations of dramatic increases in Q with outgassing up to values approaching 2000 in the seismic frequency range confirm this supposition. Measurements under confining pressures with the sample encapsulated under hard vacuum are reported to aid in the interpretation of seismic data obtained below the lunar surface. It has been possible to achieve in the experiments Q values just under 2000 at about 1 kbar for a terrestrial analog of lunar basalt. It was found that a well-outgassed sample maintains a high Q whereas one exposed to moisture maintains a low Q as the confining pressure is raised to 2.5 kbar. This result suggests that volatiles can indeed affect Q when cracks are partially closed and the high lunar seismic Q values reported are concomitant with very dry rock down to depths of at least 50 km.

  9. Tunable dark modes in one-dimensional “diatomic” dielectric gratings

    DOE PAGES

    Zeng, Bo; Majumdar, Arka; Wang, Feng

    2015-05-04

    Recently researchers have demonstrated ultra high quality factor (Q) resonances in one-dimensional (1D) dielectric gratings. Here we theoretically investigate a new class of subwavelength 1D gratings, namely “diatomic” gratings with two nonequivalent subcells in one period, and utilize their intrinsic dark modes to achieve robust ultra high Q resonances. Such “diatomic” gratings provide extra design flexibility, and enable high Q resonators using thinner geometry with smaller filling factors compared to conventional designs like the high contrast gratings (HCGs). More importantly, we show that these high Q resonances can be efficiently tuned in situ, making the design appealing in various applicationsmore » including optical sensing, filtering and displays.« less

  10. Quality correction factors of composite IMRT beam deliveries: theoretical considerations.

    PubMed

    Bouchard, Hugo

    2012-11-01

    In the scope of intensity modulated radiation therapy (IMRT) dosimetry using ionization chambers, quality correction factors of plan-class-specific reference (PCSR) fields are theoretically investigated. The symmetry of the problem is studied to provide recommendable criteria for composite beam deliveries where correction factors are minimal and also to establish a theoretical limit for PCSR delivery k(Q) factors. The concept of virtual symmetric collapsed (VSC) beam, being associated to a given modulated composite delivery, is defined in the scope of this investigation. Under symmetrical measurement conditions, any composite delivery has the property of having a k(Q) factor identical to its associated VSC beam. Using this concept of VSC, a fundamental property of IMRT k(Q) factors is demonstrated in the form of a theorem. The sensitivity to the conditions required by the theorem is thoroughly examined. The theorem states that if a composite modulated beam delivery produces a uniform dose distribution in a volume V(cyl) which is symmetric with the cylindrical delivery and all beams fulfills two conditions in V(cyl): (1) the dose modulation function is unchanged along the beam axis, and (2) the dose gradient in the beam direction is constant for a given lateral position; then its associated VSC beam produces no lateral dose gradient in V(cyl), no matter what beam modulation or gantry angles are being used. The examination of the conditions required by the theorem lead to the following results. The effect of the depth-dose gradient not being perfectly constant with depth on the VSC beam lateral dose gradient is found negligible. The effect of the dose modulation function being degraded with depth on the VSC beam lateral dose gradient is found to be only related to scatter and beam hardening, as the theorem holds also for diverging beams. The use of the symmetry of the problem in the present paper leads to a valuable theorem showing that k(Q) factors of composite IMRT beam deliveries are close to unity under specific conditions. The theoretical limit k(Q(pcsr),Q(msr) ) (f(pcsr),f(msr) )=1 is determined based on the property of PCSR deliveries to provide a uniform dose in the target volume. The present approach explains recent experimental observations and proposes ideal conditions for IMRT reference dosimetry. The result of this study could potentially serve as a theoretical basis for reference dosimetry of composite IMRT beam deliveries or for routine IMRT quality assurance.

  11. High quality-factor fano metasurface comprising a single resonator unit cell

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sinclair, Michael B.; Warne, Larry K.; Basilio, Lorena I.

    A new monolithic resonator metasurface design achieves ultra-high Q-factors while using only one resonator per unit cell. The metasurface relies on breaking the symmetry of otherwise highly symmetric resonators to induce intra-resonator mixing of bright and dark modes (rather than inter-resonator couplings), and is scalable from the near-infrared to radio frequencies and can be easily implemented in dielectric materials. The resulting high-quality-factor Fano metasurface can be used in many sensing, spectral filtering, and modulation applications.

  12. Determination of small-field correction factors for cylindrical ionization chambers using a semiempirical method

    NASA Astrophysics Data System (ADS)

    Park, Kwangwoo; Bak, Jino; Park, Sungho; Choi, Wonhoon; Park, Suk Won

    2016-02-01

    A semiempirical method based on the averaging effect of the sensitive volumes of different air-filled ionization chambers (ICs) was employed to approximate the correction factors for beam quality produced from the difference in the sizes of the reference field and small fields. We measured the output factors using several cylindrical ICs and calculated the correction factors using a mathematical method similar to deconvolution; in the method, we modeled the variable and inhomogeneous energy fluence function within the chamber cavity. The parameters of the modeled function and the correction factors were determined by solving a developed system of equations as well as on the basis of the measurement data and the geometry of the chambers. Further, Monte Carlo (MC) computations were performed using the Monaco® treatment planning system to validate the proposed method. The determined correction factors (k{{Q\\text{msr}},Q}{{f\\text{smf}}, {{f}\\text{ref}}} ) were comparable to the values derived from the MC computations performed using Monaco®. For example, for a 6 MV photon beam and a field size of 1  ×  1 cm2, k{{Q\\text{msr}},Q}{{f\\text{smf}}, {{f}\\text{ref}}} was calculated to be 1.125 for a PTW 31010 chamber and 1.022 for a PTW 31016 chamber. On the other hand, the k{{Q\\text{msr}},Q}{{f\\text{smf}}, {{f}\\text{ref}}} values determined from the MC computations were 1.121 and 1.031, respectively; the difference between the proposed method and the MC computation is less than 2%. In addition, we determined the k{{Q\\text{msr}},Q}{{f\\text{smf}}, {{f}\\text{ref}}} values for PTW 30013, PTW 31010, PTW 31016, IBA FC23-C, and IBA CC13 chambers as well. We devised a method for determining k{{Q\\text{msr}},Q}{{f\\text{smf}}, {{f}\\text{ref}}} from both the measurement of the output factors and model-based mathematical computation. The proposed method can be useful in case the MC simulation would not be applicable for the clinical settings.

  13. New determinations of Q quality factors and eigenfrequencies for the whole set of singlets of the Earth's normal modes 0S 0, 0S 2, 0S 3 and 2S 1 using superconducting gravimeter data from the GGP network

    NASA Astrophysics Data System (ADS)

    Roult, Geneviève; Rosat, Séverine; Clévédé, Eric; Millot-Langet, Raphaële; Hinderer, Jacques

    2006-01-01

    We present new modal Q measurements of the 0S 0 and 0S 2 modes, and first modal frequencies and Q measurements of 2S 1 and 0S 3 modes. The high quality of the GGP (Global Geodynamics Project) superconducting gravimeters (SGs) contributes to the clear observation of seismic normal modes at frequencies lower than 1 mHz and offers a good opportunity for studying the behaviour of these modes. The interest of scientists in the gravest normal modes is due to the fact that they do contribute to a better knowledge of the density profile in the Earth, helping to constrain Earth's models. These modes have been clearly identified after some large recent events recorded with superconducting gravimeters, particularly well-suited for low-frequency investigations. The Ms = 8.1 (Mw = 8.4) Peruvian earthquake of June 2001 and the Ms = 9.0 (Mw = 9.3) Sumatra-Andaman earthquake of December 2004 provide us with individual spectra which exhibit a clear splitting of the spheroidal modes 0S 2, 0S 3 and 2S 1, and a clear identification of each of the individual singlets, with a resolution never obtained from broad-band seismometers records. The Q quality factors have been determined from the apparent decrease of the amplitude of each singlet with time, according to a well-suited technique [Roult, G., Clévédé, E., 2000. New refinements in attenuation measurements from free-oscillation and surface-wave observations. Phys. Earth Planet. Inter. 121, 1-37]. The results are compared to the theoretical frequencies and Q quality factors computed for the PREM and 1066A models, taking into account both rotation and ellipticity effects of the Earth. The two observed datasets (frequencies and Q quality factors) exhibit a splitting on the observed values different from the predicted one. That seems to point out that some parameters as density or attenuation values used in the theoretical models do not explain the observations. A new dataset of frequencies and Q quality factors of the whole set of singlets of the gravest spheroidal modes is thus under construction. That dataset includes the five individual singlets of the 0S 2 mode clearly identified on the SG records, the three singlets of the 2S 1 mode recently observed for the first time by [Rosat, S., Hinderer, J., Rivera, L., 2003b. First observation of 2S 1 and study of the splitting of the football mode 0S 2 after the June 2001 Peru earthquake of magnitude 8.4. Geophys. Res. Lett. 30, 21211, doi:10-1029/2003L018304], the 0S 0 radial mode, and the seven individual singlets of the 0S 3 mode.

  14. High-Q silicon-on-insulator slot photonic crystal cavity infiltrated by a liquid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Caër, Charles; Le Roux, Xavier; Cassan, Eric, E-mail: eric.cassan@u-psud.fr

    We report the experimental realization of a high-Q slot photonic crystal cavity in Silicon-On-Insulator (SOI) configuration infiltrated by a liquid. Loaded Q-factor of 23 000 is measured at telecom wavelength. The intrinsic quality factor inferred from the transmission spectrum is higher than 200 000, which represents a record value for slot photonic crystal cavities on SOI, whereas the maximum of intensity of the cavity is roughly equal to 20% of the light transmitted in the waveguide. This result makes filled slot photonic crystal cavities very promising for silicon-based light emission and ultrafast nonlinear optics.

  15. Piezoelectric micromachined ultrasonic transducers with low thermoelastic dissipation and high quality factor

    NASA Astrophysics Data System (ADS)

    Chen, Xuying; Liu, Xinxin; Wang, Tao; Le, Xianhao; Ma, Fangyi; Lee, Chengkuo; Xie, Jin

    2018-05-01

    Thermoelastic dissipation is one of the main dissipative mechanisms in piezoelectric micromachined ultrasonic transducers (pMUTs). In this paper, we firstly propose pMUTs with etching holes to decrease thermoelastic dissipation and enhance quality factor (Q). The etching holes effectively disturb heat flow, and thus reduce thermoelastic loss. Working mechanism based on the Zener’s model is interpreted. The experiment results show that the Q of pMUT with three rows of holes is increased by 139% from 2050 to 4909 compared with the traditional one. Temperature coefficient of frequency (TCF) and vibration performance are also improved. The enhanced pMUT can be widely used in measurement of Doppler shift and relative high power applications.

  16. Glass-embedded two-dimensional silicon photonic crystal devices with a broad bandwidth waveguide and a high quality nanocavity.

    PubMed

    Jeon, Seung-Woo; Han, Jin-Kyu; Song, Bong-Shik; Noda, Susumu

    2010-08-30

    To enhance the mechanical stability of a two-dimensional photonic crystal slab structure and maintain its excellent performance, we designed a glass-embedded silicon photonic crystal device consisting of a broad bandwidth waveguide and a nanocavity with a high quality (Q) factor, and then fabricated the structure using spin-on glass (SOG). Furthermore, we showed that the refractive index of the SOG could be tuned from 1.37 to 1.57 by varying the curing temperature of the SOG. Finally, we demonstrated a glass-embedded heterostructured cavity with an ultrahigh Q factor of 160,000 by adjusting the refractive index of the SOG.

  17. A comparison of Q-factor estimation methods for marine seismic data

    NASA Astrophysics Data System (ADS)

    Kwon, J.; Ha, J.; Shin, S.; Chung, W.; Lim, C.; Lee, D.

    2016-12-01

    The seismic imaging technique draws information from inside the earth using seismic reflection and transmission data. This technique is an important method in geophysical exploration. Also, it has been employed widely as a means of locating oil and gas reservoirs because it offers information on geological media. There is much recent and active research into seismic attenuation and how it determines the quality of seismic imaging. Seismic attenuation is determined by various geological characteristics, through the absorption or scattering that occurs when the seismic wave passes through a geological medium. The seismic attenuation can be defined using an attenuation coefficient and represented as a non-dimensional variable known as the Q-factor. Q-factor is a unique characteristic of a geological medium. It is a very important material property for oil and gas resource development. Q-factor can be used to infer other characteristics of a medium, such as porosity, permeability and viscosity, and can directly indicate the presence of hydrocarbons to identify oil and gas bearing areas from the seismic data. There are various ways to estimate Q-factor in three different domains. In the time domain, pulse amplitude decay, pulse rising time, and pulse broadening are representative. Logarithm spectral ratio (LSR), centroid frequency shift (CFS), and peak frequency shift (PFS) are used in the frequency domain. In the time-frequency domain, Wavelet's Envelope Peak Instantaneous Frequency (WEPIF) is most frequently employed. In this study, we estimated and analyzed the Q-factor through the numerical model test and used 4 methods: the LSR, CFS, PFS, and WEPIF. Before we applied these 4 methods to observed data, we experimented with the numerical model test. The numerical model test data is derived from Norsar-2D, which is the basis of the ray-tracing algorithm, and we used reflection and normal incidence surveys to calculate Q-factor according to the array of sources and receivers. After the numerical model test, we chose the most accurate of the 4 methods by comparing Q-factor through reflection and normal incidence surveys. We applied the method to the observed data and proved its accuracy.

  18. Psychometrican analysis and dimensional structure of the Brazilian version of melasma quality of life scale (MELASQoL-BP)*

    PubMed Central

    Maranzatto, Camila Fernandes Pollo; Miot, Hélio Amante; Miot, Luciane Donida Bartoli; Meneguin, Silmara

    2016-01-01

    Background Although asymptomatic, melasma inflicts significant impact on quality of life. MELASQoL is the main instrument used to assess quality of life associated with melasma, it has been validated in several languages, but its latent dimensional structure and psychometric properties haven´t been fully explored. Objectives To evaluate psychometric characteristics, information and dimensional structure of the Brazilian version of MELASQoL. Methods Survey with patients with facial melasma through socio-demographic questionnaire, DLQI-BRA, MASI and MELASQoL-BP, exploratory and confirmatory factor analysis, internal consistency of MELASQoL and latent dimensions (Cronbach's alpha). The informativeness of the model and items were investigated by the Rasch model (ordinal data). Results We evaluated 154 patients, 134 (87%) were female, mean age (± SD) of 39 (± 8) years, the onset of melasma at 27 (± 8) years, median (p25-p75) of MASI scores , DLQI and MELASQoL 8 (5-15) 2 (1-6) and 30 (17-44). The correlation (rho) of MELASQoL with DLQI and MASI were: 0.70 and 0.36. Exploratory factor analysis identified two latent dimensions: Q1-Q3 and Q4-Q10, which had significantly more adjusted factor structure than the one-dimensional model: Χ2 / gl = 2.03, CFI = 0.95, AGFI = 0.94, RMSEA = 0.08. Cronbach's coefficient for the one-dimensional model and the factors were: 0.95, 0.92 and 0.93. Rasch analysis demonstrated that the use of seven alternatives per item resulted in no increase in the model informativeness. Conclusions MELASQoL-BP showed good psychometric performance and a latent structure of two dimensions. We also identified an oversizing of item alternatives to characterize the aggregate information to each dimension. PMID:27579735

  19. High-Q and highly reproducible microdisks and microlasers.

    PubMed

    Zhang, Nan; Wang, Yujie; Sun, Wenzhao; Liu, Shuai; Huang, Can; Jiang, Xiaoshun; Xiao, Min; Xiao, Shumin; Song, Qinghai

    2018-01-25

    High quality (Q) factor microdisks are fundamental building blocks of on-chip integrated photonic circuits and biological sensors. The resonant modes in microdisks circulate near their boundaries, making their performances strongly dependent upon surface roughness. Surface-tension-induced microspheres and microtoroids are superior to other dielectric microdisks when comparing Q factors. However, most photonic materials such as silicon and negative photoresists are hard to be reflowed and thus the realizations of high-Q microdisks are strongly dependent on electron-beam lithography. Herein, we demonstrate a robust, cost-effective, and highly reproducible technique to fabricate ultrahigh-Q microdisks. By using silica microtoroids as masks, we have successfully replicated their ultrasmooth boundaries in a photoresist via anisotropic dry etching. The experimentally recorded Q factors of passive microdisks can be as large as 1.5 × 10 6 . Similarly, ultrahigh Q microdisk lasers have also been replicated in dye-doped polymeric films. The laser linewidth is only 8 pm, which is limited by the spectrometer and is much narrower than that in previous reports. Meanwhile, high-Q deformed microdisks have also been fabricated by controlling the shape of microtoroids, making the internal ray dynamics and external directional laser emissions controllable. Interestingly, this technique also applies to other materials. Silicon microdisks with Q > 10 6 have been experimentally demonstrated with a similar process. We believe this research will be important for the advances of high-Q micro-resonators and their applications.

  20. High quality factor, fully switchable terahertz superconducting metasurface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scalari, G., E-mail: scalari@phys.ethz.ch; Maissen, C.; Faist, J.

    2014-12-29

    We present a complementary THz metasurface realised with Niobium thin film which displays a quality factor Q = 54 and a fully switchable behaviour as a function of the temperature. The switching behaviour and the high quality factor are due to a careful design of the metasurface aimed at maximising the ohmic losses when the Nb is above the critical temperature and minimising the radiative coupling. The superconductor allows the operation of the cavity with high Q and the use of inductive elements with a high aspect ratio. Comparison with three dimensional finite element simulations highlights the crucial role of the inductivemore » elements and of the kinetic inductance of the Cooper pairs in achieving the high quality factor and the high field enhancement.« less

  1. On Strong Positive Frequency Dependencies of Quality Factors in Local-Earthquake Seismic Studies

    NASA Astrophysics Data System (ADS)

    Morozov, Igor B.; Jhajhria, Atul; Deng, Wubing

    2018-03-01

    Many observations of seismic waves from local earthquakes are interpreted in terms of the frequency-dependent quality factor Q( f ) = Q0 f^{η } , where η is often close to or exceeds one. However, such steep positive frequency dependencies of Q require careful analysis with regard to their physical consistency. In particular, the case of η = 1 corresponds to frequency-independent (elastic) amplitude decays with time and consequently requires no Q-type attenuation mechanisms. For η > 1, several problems with physical meanings of such Q-factors occur. First, contrary to the key premise of seismic attenuation, high-frequency parts of the wavefield are enhanced with increasing propagation times relative to the low-frequency ones. Second, such attenuation cannot be implemented by mechanical models of wave-propagating media. Third, with η > 1, the velocity dispersion associated with such Q(f) occurs over unrealistically short frequency range and has an unexpected oscillatory shape. Cases η = 1 and η > 1 are usually attributed to scattering; however, this scattering must exhibit fortuitous tuning into the observation frequency band, which appears unlikely. The reason for the above problems is that the inferred Q values are affected by the conventional single-station measurement procedure. Both parameters Q 0 and are apparent, i.e., dependent on the selected parameterization and inversion method, and they should not be directly attributed to the subsurface. For η ≈ 1, parameter Q 0 actually describes the frequency-independent amplitude decay in access of some assumed geometric spreading t -α , where α is usually taken equal one. The case η > 1 is not allowed physically and could serve as an indicator of problematic interpretations. Although the case 0 < η < 1 is possible, its parameters Q 0 and may also be biased by the measurement procedure. To avoid such difficulties of Q-based approaches, we recommend measuring and interpreting the amplitude-decay rates (such as parameter α) directly.

  2. High quality factor GaAs-based photonic crystal microcavities by epitaxial re-growth.

    PubMed

    Prieto, Ivan; Herranz, Jesús; Wewior, Lukasz; González, Yolanda; Alén, Benito; González, Luisa; Postigo, Pablo A

    2013-12-16

    We investigate L7 photonic crystal microcavities (PCMs) fabricated by epitaxial re-growth of GaAs pre-patterned substrates, containing InAs quantum dots. The resulting PCMs show hexagonal shaped nano-holes due to the development of preferential crystallographic facets during the re-growth step. Through a careful control of the fabrication processes, we demonstrate that the photonic modes are preserved throughout the process. The quality factor (Q) of the photonic modes in the re-grown PCMs strongly depends on the relative orientation between photonic lattice and crystallographic directions. The optical modes of the re-grown PCMs preserve the linear polarization and, for the most favorable orientation, a 36% of the Q measured in PCMs fabricated by the conventional procedure is observed, exhibiting values up to ~6000. The results aim to the future integration of site-controlled QDs with high-Q PCMs for quantum photonics and quantum integrated circuits.

  3. Left Handed Materials Based on Magnetic Nanocomposites

    DTIC Science & Technology

    2006-10-18

    theory that unifies DNMs and SNMs as a function of two flmdamental material parameters: quality factors for permittivity (Qe=e’/e") and permeability (Qu...simultaneously negative effective permeability/uff and permittivity Seff to form LHM or only single negative parameter (SNM) to form negative indexed...developed a theory that unifies DNMs and SNMs as a function of two fundamental material parameters: quality factors for permittivity (Q, = -’/ 6") and

  4. Combination of classical test theory (CTT) and item response theory (IRT) analysis to study the psychometric properties of the French version of the Quality of Life Enjoyment and Satisfaction Questionnaire-Short Form (Q-LES-Q-SF).

    PubMed

    Bourion-Bédès, Stéphanie; Schwan, Raymund; Epstein, Jonathan; Laprevote, Vincent; Bédès, Alex; Bonnet, Jean-Louis; Baumann, Cédric

    2015-02-01

    The study aimed to examine the construct validity and reliability of the Quality of Life Enjoyment and Satisfaction Questionnaire-Short Form (Q-LES-Q-SF) according to both classical test and item response theories. The psychometric properties of the French version of this instrument were investigated in a cross-sectional, multicenter study. A total of 124 outpatients with a substance dependence diagnosis participated in the study. Psychometric evaluation included descriptive analysis, internal consistency, test-retest reliability, and validity. The dimensionality of the instrument was explored using a combination of the classical test, confirmatory factor analysis (CFA), and an item response theory analysis, the Person Separation Index (PSI), in a complementary manner. The results of the Q-LES-Q-SF revealed that the questionnaire was easy to administer and the acceptability was good. The internal consistency and the test-retest reliability were 0.9 and 0.88, respectively. All items were significantly correlated with the total score and the SF-12 used in the study. The CFA with one factor model was good, and for the unidimensional construct, the PSI was found to be 0.902. The French version of the Q-LES-Q-SF yielded valid and reliable clinical assessments of the quality of life for future research and clinical practice involving French substance abusers. In response to recent questioning regarding the unidimensionality or bidimensionality of the instrument and according to the underlying theoretical unidimensional construct used for its development, this study suggests the Q-LES-Q-SF as a one-dimension questionnaire in French QoL studies.

  5. Modeling of High-Quality Factor XNOR Gate Using Quantum-Dot Semiconductor Optical Amplifiers at 1 Tb/s

    NASA Astrophysics Data System (ADS)

    Kotb, Amer

    2015-06-01

    The modeling of all-optical logic XNOR gate is realized by a series combination of XOR and INVERT gates. This Boolean function is simulated by using Mach-Zehnder interferometers (MZIs) utilizing quantum-dots semiconductor optical amplifiers (QDs-SOAs). The study is carried out when the effect of amplified spontaneous emission (ASE) is included. The dependence of the output quality factor ( Q-factor) on signals and QDs-SOAs' parameters is also investigated and discussed. The simulation is conducted under a repetition rate of ˜1 Tb/s.

  6. A novel approach to the analysis of squeezed-film air damping in microelectromechanical systems

    NASA Astrophysics Data System (ADS)

    Yang, Weilin; Li, Hongxia; Chatterjee, Aveek N.; Elfadel, Ibrahim (Abe M.; Ender Ocak, Ilker; Zhang, TieJun

    2017-01-01

    Squeezed-film damping (SFD) is a phenomenon that significantly affects the performance of micro-electro-mechanical systems (MEMS). The total damping force in MEMS mainly include the viscous damping force and elastic damping force. Quality factor (Q factor) is usually used to evaluate the damping in MEMS. In this work, we measure the Q factor of a resonator through experiments in a wide range of pressure levels. In fact, experimental characterizations of MEMS have some limitations because it is difficult to conduct experiments at very high vacuum and also hard to differentiate the damping mechanisms from the overall Q factor measurements. On the other hand, classical theoretical analysis of SFD is restricted to strong assumptions and simple geometries. In this paper, a novel numerical approach, which is based on lattice Boltzmann simulations, is proposed to investigate SFD in MEMS. Our method considers the dynamics of squeezed air flow as well as fluid-solid interactions in MEMS. It is demonstrated that Q factor can be directly predicted by numerical simulation, and our simulation results agree well with experimental data. Factors that influence SFD, such as pressure, oscillating amplitude, and driving frequency, are investigated separately. Furthermore, viscous damping and elastic damping forces are quantitatively compared based on comprehensive simulation. The proposed numerical approach as well as experimental characterization enables us to reveal the insightful physics of squeezed-film air damping in MEMS.

  7. Quality factor of luminescent solar concentrators and practical concentration limits attainable with semiconductor quantum dots

    DOE PAGES

    Klimov, Victor I.; Baker, Thomas A.; Lim, Jaehoon; ...

    2016-05-09

    In this study, luminescent solar concentrators (LSCs) can be utilized as both large-area collectors of solar radiation supplementing traditional photovoltaic cells as well as semitransparent “solar windows” that provide a desired degree of shading and simultaneously serve as power-generation units. An important characteristic of an LSC is a concentration factor (C) that can be thought of as a coefficient of effective enlargement (or contraction) of the area of a solar cell when it is coupled to the LSC. Here we use analytical and numerical Monte Carlo modeling in addition to experimental studies of quantum-dot-based LSCs to analyze the factors thatmore » influence optical concentration in practical devices. Our theoretical model indicates that the maximum value of C achievable with a given fluorophore is directly linked to the LSC quality factor (Q LSC) defined as the ratio of absorption coefficients at the wavelengths of incident and reemitted light. In fact, we demonstrate that the ultimate concentration limit (C 0) realized in large-area devices scales linearly with the LSC quality factor and in the case of perfect emitters and devices without back reflectors is approximately equal to Q LSC. To test the predictions of this model, we conduct experimental studies of LSCs based on visible-light emitting II–VI core/shell quantum dots with two distinct LSC quality factors. We also investigate devices based on near-infrared emitting CuInSe xS 2–x quantum dots for which the large emission bandwidth allows us to assess the impact of varied Q LSC on the concentration factor by simply varying the detection wavelength. In all cases, we find an excellent agreement between the model and the experimental observations, suggesting that the developed formalism can be utilized for express evaluation of prospective LSC performance based on the optical spectra of LSC fluorophores, which should facilitate future efforts on the development of high-performance devices based on quantum dots as well as other types of emitters.« less

  8. Quality factor of luminescent solar concentrators and practical concentration limits attainable with semiconductor quantum dots

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klimov, Victor I.; Baker, Thomas A.; Lim, Jaehoon

    In this study, luminescent solar concentrators (LSCs) can be utilized as both large-area collectors of solar radiation supplementing traditional photovoltaic cells as well as semitransparent “solar windows” that provide a desired degree of shading and simultaneously serve as power-generation units. An important characteristic of an LSC is a concentration factor (C) that can be thought of as a coefficient of effective enlargement (or contraction) of the area of a solar cell when it is coupled to the LSC. Here we use analytical and numerical Monte Carlo modeling in addition to experimental studies of quantum-dot-based LSCs to analyze the factors thatmore » influence optical concentration in practical devices. Our theoretical model indicates that the maximum value of C achievable with a given fluorophore is directly linked to the LSC quality factor (Q LSC) defined as the ratio of absorption coefficients at the wavelengths of incident and reemitted light. In fact, we demonstrate that the ultimate concentration limit (C 0) realized in large-area devices scales linearly with the LSC quality factor and in the case of perfect emitters and devices without back reflectors is approximately equal to Q LSC. To test the predictions of this model, we conduct experimental studies of LSCs based on visible-light emitting II–VI core/shell quantum dots with two distinct LSC quality factors. We also investigate devices based on near-infrared emitting CuInSe xS 2–x quantum dots for which the large emission bandwidth allows us to assess the impact of varied Q LSC on the concentration factor by simply varying the detection wavelength. In all cases, we find an excellent agreement between the model and the experimental observations, suggesting that the developed formalism can be utilized for express evaluation of prospective LSC performance based on the optical spectra of LSC fluorophores, which should facilitate future efforts on the development of high-performance devices based on quantum dots as well as other types of emitters.« less

  9. Quality correction factors of composite IMRT beam deliveries: Theoretical considerations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bouchard, Hugo

    2012-11-15

    Purpose: In the scope of intensity modulated radiation therapy (IMRT) dosimetry using ionization chambers, quality correction factors of plan-class-specific reference (PCSR) fields are theoretically investigated. The symmetry of the problem is studied to provide recommendable criteria for composite beam deliveries where correction factors are minimal and also to establish a theoretical limit for PCSR delivery k{sub Q} factors. Methods: The concept of virtual symmetric collapsed (VSC) beam, being associated to a given modulated composite delivery, is defined in the scope of this investigation. Under symmetrical measurement conditions, any composite delivery has the property of having a k{sub Q} factor identicalmore » to its associated VSC beam. Using this concept of VSC, a fundamental property of IMRT k{sub Q} factors is demonstrated in the form of a theorem. The sensitivity to the conditions required by the theorem is thoroughly examined. Results: The theorem states that if a composite modulated beam delivery produces a uniform dose distribution in a volume V{sub cyl} which is symmetric with the cylindrical delivery and all beams fulfills two conditions in V{sub cyl}: (1) the dose modulation function is unchanged along the beam axis, and (2) the dose gradient in the beam direction is constant for a given lateral position; then its associated VSC beam produces no lateral dose gradient in V{sub cyl}, no matter what beam modulation or gantry angles are being used. The examination of the conditions required by the theorem lead to the following results. The effect of the depth-dose gradient not being perfectly constant with depth on the VSC beam lateral dose gradient is found negligible. The effect of the dose modulation function being degraded with depth on the VSC beam lateral dose gradient is found to be only related to scatter and beam hardening, as the theorem holds also for diverging beams. Conclusions: The use of the symmetry of the problem in the present paper leads to a valuable theorem showing that k{sub Q} factors of composite IMRT beam deliveries are close to unity under specific conditions. The theoretical limit k{sub Q{sub p{sub c{sub s{sub r,Q{sub m{sub s{sub r}{sup f{sub p}{sub c}{sub s}{sub r},f{sub m}{sub s}{sub r}}}}}}}}}=1 is determined based on the property of PCSR deliveries to provide a uniform dose in the target volume. The present approach explains recent experimental observations and proposes ideal conditions for IMRT reference dosimetry. The result of this study could potentially serve as a theoretical basis for reference dosimetry of composite IMRT beam deliveries or for routine IMRT quality assurance.« less

  10. An Analysis Method for Superconducting Resonator Parameter Extraction with Complex Baseline Removal

    NASA Technical Reports Server (NTRS)

    Cataldo, Giuseppe

    2014-01-01

    A new semi-empirical model is proposed for extracting the quality (Q) factors of arrays of superconducting microwave kinetic inductance detectors (MKIDs). The determination of the total internal and coupling Q factors enables the computation of the loss in the superconducting transmission lines. The method used allows the simultaneous analysis of multiple interacting discrete resonators with the presence of a complex spectral baseline arising from reflections in the system. The baseline removal allows an unbiased estimate of the device response as measured in a cryogenic instrumentation setting.

  11. Design and optical characterization of high-Q guided-resonance modes in the slot-graphite photonic crystal lattice.

    PubMed

    Martínez, Luis Javier; Huang, Ningfeng; Ma, Jing; Lin, Chenxi; Jaquay, Eric; Povinelli, Michelle L

    2013-12-16

    A new photonic crystal structure is generated by using a regular graphite lattice as the base and adding a slot in the center of each unit cell to enhance field confinement. The theoretical Q factor in an ideal structure is over 4 × 10(5). The structure was fabricated on a silicon-on-insulator wafer and optically characterized by transmission spectroscopy. The resonance wavelength and quality factor were measured as a function of slot height. The measured trends show good agreement with simulation.

  12. Features of Radiation and Propagation of Seismic Waves in the Northern Caucasus: Manifestations in Regional Coda

    NASA Astrophysics Data System (ADS)

    Kromskii, S. D.; Pavlenko, O. V.; Gabsatarova, I. P.

    2018-03-01

    Based on the Anapa (ANN) seismic station records of 40 earthquakes ( M W > 3.9) that occurred within 300 km of the station since 2002 up to the present time, the source parameters and quality factor of the Earth's crust ( Q( f)) and upper mantle are estimated for the S-waves in the 1-8 Hz frequency band. The regional coda analysis techniques which allow separating the effects associated with seismic source (source effects) and with the propagation path of seismic waves (path effects) are employed. The Q-factor estimates are obtained in the form Q( f) = 90 × f 0.7 for the epicentral distances r < 120 km and in the form Q( f) = 90 × f1.0 for r > 120 km. The established Q( f) and source parameters are close to the estimates for Central Japan, which is probably due to the similar tectonic structure of the regions. The shapes of the source parameters are found to be independent of the magnitude of the earthquakes in the magnitude range 3.9-5.6; however, the radiation of the high-frequency components ( f > 4-5 Hz) is enhanced with the depth of the source (down to h 60 km). The estimates Q( f) of the quality factor determined from the records by the Sochi, Anapa, and Kislovodsk seismic stations allowed a more accurate determination of the seismic moments and magnitudes of the Caucasian earthquakes. The studies will be continued for obtaining the Q( f) estimates, geometrical spreading functions, and frequency-dependent amplification of seismic waves in the Earth's crust in the other regions of the Northern Caucasus.

  13. Absorption band Q model for the Earth

    NASA Technical Reports Server (NTRS)

    Anderson, D. L.; Given, J. W.

    1981-01-01

    Attenuation in solids and liquids, as measured by the quality factor Q, is typically frequency dependent. In seismology, however, Q is usually assumed to be independent of frequency. Body wave, surface wave, and normal mode data are used to place constraints on the frequency dependence of Q in the mantle. Specific features of the absorption band model are: low-Q in the seismic band at both the top and the base of the mantle, low-Q for long-period body waves in the outer core, an inner core Q sub s that increases with period, and low Q sub p/Q sub s at short periods in the middle mantle.

  14. Effective bichromatic potential for ultra-high Q-factor photonic crystal slab cavities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alpeggiani, Filippo, E-mail: filippo.alpeggiani01@ateneopv.it; Andreani, Lucio Claudio; Gerace, Dario

    2015-12-28

    We introduce a confinement mechanism in photonic crystal slab cavities, which relies on the superposition of two incommensurate one-dimensional lattices in a line-defect waveguide. It is shown that the resulting photonic profile realizes an effective quasi-periodic bichromatic potential for the electromagnetic field confinement yielding extremely high quality (Q) factor nanocavities, while simultaneously keeping the mode volume close to the diffraction limit. We apply these concepts to pillar- and hole-based photonic crystal slab cavities, respectively, and a Q-factor improvement by over an order of magnitude is shown over existing designs, especially in pillar-based structures. Thanks to the generality and easy adaptationmore » of such confinement mechanism to a broad class of cavity designs and photonic lattices, this work opens interesting routes for applications where enhanced light–matter interaction in photonic crystal structures is required.« less

  15. Demonstration of a switchable damping system to allow low-noise operation of high-Q low-mass suspension systems

    NASA Astrophysics Data System (ADS)

    Hennig, Jan-Simon; Barr, Bryan W.; Bell, Angus S.; Cunningham, William; Danilishin, Stefan L.; Dupej, Peter; Gräf, Christian; Hough, James; Huttner, Sabina H.; Jones, Russell; Leavey, Sean S.; Pascucci, Daniela; Sinclair, Martin; Sorazu, Borja; Spencer, Andrew; Steinlechner, Sebastian; Strain, Kenneth A.; Wright, Jennifer; Zhang, Teng; Hild, Stefan

    2017-12-01

    Low-mass suspension systems with high-Q pendulum stages are used to enable quantum radiation pressure noise limited experiments. Utilizing multiple pendulum stages with vertical blade springs and materials with high-quality factors provides attenuation of seismic and thermal noise; however, damping of these high-Q pendulum systems in multiple degrees of freedom is essential for practical implementation. Viscous damping such as eddy-current damping can be employed, but it introduces displacement noise from force noise due to thermal fluctuations in the damping system. In this paper we demonstrate a passive damping system with adjustable damping strength as a solution for this problem that can be used for low-mass suspension systems without adding additional displacement noise in science mode. We show a reduction of the damping factor by a factor of 8 on a test suspension and provide a general optimization for this system.

  16. Region-specific S-wave attenuation for earthquakes in northwestern Iran

    NASA Astrophysics Data System (ADS)

    Heidari, Reza; Mirzaei, Noorbakhsh

    2017-11-01

    In this study, continuous wavelet transform is applied to estimate the frequency-dependent quality factor of shear waves, Q S , in northwestern Iran. The dataset used in this study includes velocigrams of more than 50 events with magnitudes between 4.0 and 6.5, which have occurred in the study area. The CWT-based method shows a high-resolution technique for the estimation of S-wave frequency-dependent attenuation. The quality factor values are determined in the form of a power law as Q S ( f) = (147 ± 16) f 0.71 ± 0.02 and (126 ± 12) f 0.73 ± 0.02 for vertical and horizontal components, respectively, where f is between 0.9 and 12 Hz. Furthermore, in order to verify the reliability of the suggested Q S estimator method, an additional test is performed by using accelerograms of Ahar-Varzaghan dual earthquakes on August 11, 2012, of moment magnitudes 6.4 and 6.3 and their aftershocks. Results indicate that the estimated Q S values from CWT-based method are not very sensitive to the numbers and types of waveforms used (velocity or acceleration).

  17. Experimental validation of beam quality correction factors for proton beams

    NASA Astrophysics Data System (ADS)

    Gomà, Carles; Hofstetter-Boillat, Bénédicte; Safai, Sairos; Vörös, Sándor

    2015-04-01

    This paper presents a method to experimentally validate the beam quality correction factors (kQ) tabulated in IAEA TRS-398 for proton beams and to determine the kQ of non-tabulated ionization chambers (based on the already tabulated values). The method is based exclusively on ionometry and it consists in comparing the reading of two ionization chambers under the same reference conditions in a proton beam quality Q and a reference beam quality 60Co. This allows one to experimentally determine the ratio between the kQ of the two ionization chambers. In this work, 7 different ionization chamber models were irradiated under the IAEA TRS-398 reference conditions for 60Co beams and proton beams. For the latter, the reference conditions for both modulated beams (spread-out Bragg peak field) and monoenergetic beams (pseudo-monoenergetic field) were studied. For monoenergetic beams, it was found that the experimental kQ values obtained for plane-parallel chambers are consistent with the values tabulated in IAEA TRS-398; whereas the kQ values obtained for cylindrical chambers are not consistent—being higher than the tabulated values. These results support the suggestion (of previous publications) that the IAEA TRS-398 reference conditions for monoenergetic proton beams should be revised so that the effective point of measurement of cylindrical ionization chambers is taken into account when positioning the reference point of the chamber at the reference depth. For modulated proton beams, the tabulated kQ values of all the ionization chambers studied in this work were found to be consistent with each other—except for the IBA FC65-G, whose experimental kQ value was found to be 0.6% lower than the tabulated one. The kQ of the PTW Advanced Markus chamber, which is not tabulated in IAEA TRS-398, was found to be 0.997 ± 0.042 (k = 2), based on the tabulated value of the PTW Markus chamber.

  18. Fabrication of Silica Ultra High Quality Factor Microresonators

    PubMed Central

    Maker, Ashley J.; Armani, Andrea M.

    2012-01-01

    Whispering gallery resonant cavities confine light in circular orbits at their periphery.1-2 The photon storage lifetime in the cavity, quantified by the quality factor (Q) of the cavity, can be in excess of 500ns for cavities with Q factors above 100 million. As a result of their low material losses, silica microcavities have demonstrated some of the longest photon lifetimes to date1-2. Since a portion of the circulating light extends outside the resonator, these devices can also be used to probe the surroundings. This interaction has enabled numerous experiments in biology, such as single molecule biodetection and antibody-antigen kinetics, as well as discoveries in other fields, such as development of ultra-low-threshold microlasers, characterization of thin films, and cavity quantum electrodynamics studies.3-7 The two primary silica resonant cavity geometries are the microsphere and the microtoroid. Both devices rely on a carbon dioxide laser reflow step to achieve their ultra-high-Q factors (Q>100 million).1-2,8-9 However, there are several notable differences between the two structures. Silica microspheres are free-standing, supported by a single optical fiber, whereas silica microtoroids can be fabricated on a silicon wafer in large arrays using a combination of lithography and etching steps. These differences influence which device is optimal for a given experiment. Here, we present detailed fabrication protocols for both types of resonant cavities. While the fabrication of microsphere resonant cavities is fairly straightforward, the fabrication of microtoroid resonant cavities requires additional specialized equipment and facilities (cleanroom). Therefore, this additional requirement may also influence which device is selected for a given experiment. Introduction An optical resonator efficiently confines light at specific wavelengths, known as the resonant wavelengths of the device. 1-2 The common figure of merit for these optical resonators is the quality factor or Q. This term describes the photon lifetime (τo) within the resonator, which is directly related to the resonator's optical losses. Therefore, an optical resonator with a high Q factor has low optical losses, long photon lifetimes, and very low photon decay rates (1/τo). As a result of the long photon lifetimes, it is possible to build-up extremely large circulating optical field intensities in these devices. This very unique property has allowed these devices to be used as laser sources and integrated biosensors.10 A unique sub-class of resonators is the whispering gallery mode optical microcavity. In these devices, the light is confined in circular orbits at the periphery. Therefore, the field is not completely confined within the device, but evanesces into the environment. Whispering gallery mode optical cavities have demonstrated some of the highest quality factors of any optical resonant cavity to date.9,11 Therefore, these devices are used throughout science and engineering, including in fundamental physics studies and in telecommunications as well as in biodetection experiments. 3-7,12 Optical microcavities can be fabricated from a wide range of materials and in a wide variety of geometries. A few examples include silica and silicon microtoroids, silicon, silicon nitride, and silica microdisks, micropillars, and silica and polymer microrings.13-17 The range in quality factor (Q) varies as dramatically as the geometry. Although both geometry and high Q are important considerations in any field, in many applications, there is far greater leverage in boosting device performance through Q enhancement. Among the numerous options detailed previously, the silica microsphere and the silica microtoroid resonator have achieved some of the highest Q factors to date.1,9 Additionally, as a result of the extremely low optical loss of silica from the visible through the near-IR, both microspheres and microtoroids are able to maintain their Q factors over a wide range of testing wavelengths.18 Finally, because silica is inherently biocompatible, it is routinely used in biodetection experiments. In addition to high material absorption, there are several other potential loss mechanisms, including surface roughness, radiation loss, and contamination loss.2 Through an optimization of the device size, it is possible to eliminate radiation losses, which arise from poor optical field confinement within the device. Similarly, by storing a device in an appropriately clean environment, contamination of the surface can be minimized. Therefore, in addition to material loss, surface scattering is the primary loss mechanism of concern.2,8 In silica devices, surface scattering is minimized by using a laser reflow technique, which melts the silica through surface tension induced reflow. While spherical optical resonators have been studied for many years, it is only with recent advances in fabrication technologies that researchers been able to fabricate high quality silica optical toroidal microresonators (Q>100 million) on a silicon substrate, thus paving the way for integration with microfluidics.1 The present series of protocols details how to fabricate both silica microsphere and microtoroid resonant cavities. While silica microsphere resonant cavities are well-established, microtoroid resonant cavities were only recently invented.1 As many of the fundamental methods used to fabricate the microsphere are also used in the more complex microtoroid fabrication procedure, by including both in a single protocol it will enable researchers to more easily trouble-shoot their experiments. PMID:22805153

  19. Theory of coupled resonator optical waveguides exhibiting high-order exceptional points of degeneracy

    NASA Astrophysics Data System (ADS)

    Nada, Mohamed Y.; Othman, Mohamed A. K.; Capolino, Filippo

    2017-11-01

    We present an approach and a theoretical framework for generating high-order exceptional points of degeneracy (EPDs) in photonic structures based on periodic coupled resonator optical waveguides (CROWs). Such EPDs involve the coalescence of Floquet-Bloch eigenwaves in CROWs, without the presence of gain and loss, which contrasts with the parity-time symmetry required to develop exceptional points based on gain and loss balance. The EPDs arise here by introducing symmetry breaking in a conventional chain of coupled resonators through periodic coupling to an adjacent uniform optical waveguide, which leads to unique modal characteristics that cannot be realized in conventional CROWs. Such remarkable characteristics include high quality factors (Q factors) and strong field enhancement, even without any mirrors at the two ends of a cavity. We show for the first time the capability of CROWs to exhibit EPDs of various orders, including the degenerate band edge (DBE) and the stationary inflection point. The proposed CROW of finite length shows an enhanced quality factor when operating near the DBE, and the Q factor exhibits an unconventional scaling with the CROW's length. We develop the theory of EPDs in such unconventional CROW using coupled-wave equations, and we derive an analytical expression for the dispersion relation. The proposed unconventional CROW concepts have various potential applications including Q switching, nonlinear devices, lasers, and extremely sensitive sensors.

  20. Calculation of k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} for several small detectors and for two linear accelerators using Monte Carlo simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Francescon, P.; Cora, S.; Satariano, N.

    2011-12-15

    Purpose: The scope of this study was to determine a complete set of correction factors for several detectors in static small photon fields for two linear accelerators (linacs) and for several detectors. Methods: Measurements for Monte Carlo (MC) commissioning were performed for two linacs, Siemens Primus and Elekta Synergy. After having determined the source parameters that best fit the measurements of field specific output factors, profiles, and tissue-phantom ratio, the generalized version of the classical beam quality correction factor for static small fields, k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}},more » were determined for several types of detectors by using the egs{sub c}hamber Monte Carlo user code which can accurately reproduce the geometry and the material composition of the detector. The influence of many parameters (energy and radial FWHM of the electron beam source, field dimensions, type of accelerator) on the value of k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} was evaluated. Moreover, a MC analysis of the parameters that influence the change of k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} as a function of field dimension was performed. A detailed analysis of uncertainties related to the measurements of the field specific output factor and to the Monte Carlo calculation of k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} was done. Results: The simulations demonstrated that the correction factor k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} can be considered independent from the quality beam factor Q in the range 0.68 {+-} 0.01 for all the detectors analyzed. The k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} of PTW 60012 and EDGE diodes can be assumed dependent only on the field size, for fields down to 0.5 x 0.5 cm{sup 2}. The microLion, and the microchambers, instead, must be used with some caution because they exhibit a slight dependence on the radial FWHM of the electron source, and therefore, a correction factor only dependent on field size can be used for fields {>=}0.75 x 0.75 and {>=}1.0 x 1.0 cm{sup 2}, respectively. The analysis of uncertainties gave an estimate of uncertainty for the 0.5 x 0.5 cm{sup 2} field of about 0.7% (1{sigma}) for k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} factor and of about 1.0% (1{sigma}) for the field output factor, {Omega}{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}}, of diodes, microchambers, and microLion. Conclusions: Stereotactic diodes with the appropriate k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} are recommended for determining {Omega}{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} of small photon beams.« less

  1. A Thermoelastic Damping Model for the Cone Microcantilever Resonator with Circular Cross-section

    NASA Astrophysics Data System (ADS)

    Li, Pu; Zhou, Hongyue

    2017-07-01

    Microbeams with variable cross-section have been applied in Microelectromechanical Systems (MEMS) resonators. Quality factor (Q-factor) is an important factor evaluating the performance of MEMS resonators, and high Q-factor stands for the excellent performance. Thermoelastic damping (TED), which has been verified as a fundamental energy lost mechanism for microresonators, determines the upper limit of Q-factor. TED can be calculated by the Zener’s model and Lifshits and Roukes (LR) model. However, for microbeam resonators with variable cross-sections, these two models become invalid in some cases. In this work, we derived the TED model for cone microcantilever with circular cross-section that is a representative non-uniform microbeam. The comparison of results obtained by the present model and Finite Element Method (FEM) model proves that the present model is valid for predicting TED value for cone microcantilever with circular cross-section. The results suggest that the first-order natural frequencies and TED values of cone microcantilever are larger than those of uniform microbeam for large aspect ratios (l/r 0). In addition, the Debye peak value of a uniform microcantilever is equal to 0.5ΔE, while that of cone microcantilever is about 0.438ΔE.

  2. Understanding Quality Factor Degradation in Superconducting Niobium Cavities at Low Microwave Field Amplitudes

    DOE PAGES

    Romanenko, A.; Schuster, D. I.

    2017-12-28

    In niobium superconducting radio frequency (SRF) cavities for particle acceleration, a decrease of the quality factor at lower fields—a so-called low field Q slope or LFQS—has been a long-standing unexplained effect. By extending the high Q measurement techniques to ultralow fields, we discover two previously unknown features of the effect: (i) saturation at rf fields lower than E acc~0.1 MV/m; (ii) strong degradation enhancement by growing thicker niobium pentoxide. Our findings suggest that the LFQS may be caused by the two level systems in the natural niobium oxide on the inner cavity surface, thereby identifying a new source of residual resistance andmore » providing guidance for potential nonaccelerator low-field applications of SRF cavities.« less

  3. Understanding Quality Factor Degradation in Superconducting Niobium Cavities at Low Microwave Field Amplitudes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Romanenko, A.; Schuster, D. I.

    In niobium superconducting radio frequency (SRF) cavities for particle acceleration, a decrease of the quality factor at lower fields—a so-called low field Q slope or LFQS—has been a long-standing unexplained effect. By extending the high Q measurement techniques to ultralow fields, we discover two previously unknown features of the effect: (i) saturation at rf fields lower than E acc~0.1 MV/m; (ii) strong degradation enhancement by growing thicker niobium pentoxide. Our findings suggest that the LFQS may be caused by the two level systems in the natural niobium oxide on the inner cavity surface, thereby identifying a new source of residual resistance andmore » providing guidance for potential nonaccelerator low-field applications of SRF cavities.« less

  4. Simple Optoelectronic Feedback in Microwave Oscillators

    NASA Technical Reports Server (NTRS)

    Maleki, Lute; Iltchenko, Vladimir

    2009-01-01

    A proposed method of stabilizing microwave and millimeter-wave oscillators calls for the use of feedback in optoelectronic delay lines characterized by high values of the resonance quality factor (Q). The method would extend the applicability of optoelectronic feedback beyond the previously reported class of optoelectronic oscillators that comprise two-port electronic amplifiers in closed loops with high-Q feedback circuits.

  5. Ionization chamber-based reference dosimetry of intensity modulated radiation beams.

    PubMed

    Bouchard, Hugo; Seuntjens, Jan

    2004-09-01

    The present paper addresses reference dose measurements using thimble ionization chambers for quality assurance in IMRT fields. In these radiation fields, detector fluence perturbation effects invalidate the application of open-field dosimetry protocol data for the derivation of absorbed dose to water from ionization chamber measurements. We define a correction factor C(Q)IMRT to correct the absorbed dose to water calibration coefficient N(D, w)Q for fluence perturbation effects in individual segments of an IMRT delivery and developed a calculation method to evaluate the factor. The method consists of precalculating, using accurate Monte Carlo techniques, ionization chamber, type-dependent cavity air dose, and in-phantom dose to water at the reference point for zero-width pencil beams as a function of position of the pencil beams impinging on the phantom surface. These precalculated kernels are convolved with the IMRT fluence distribution to arrive at the dose-to-water-dose-to-cavity air ratio [D(a)w (IMRT)] for IMRT fields and with a 10x10 cm2 open-field fluence to arrive at the same ratio D(a)w (Q) for the 10x10 cm2 reference field. The correction factor C(Q)IMRT is then calculated as the ratio of D(a)w (IMRT) and D(a)w (Q). The calculation method was experimentally validated and the magnitude of chamber correction factors in reference dose measurements in single static and dynamic IMRT fields was studied. The results show that, for thimble-type ionization chambers the correction factor in a single, realistic dynamic IMRT field can be of the order of 10% or more. We therefore propose that for accurate reference dosimetry of complete n-beam IMRT deliveries, ionization chamber fluence perturbation correction factors must explicitly be taken into account.

  6. SU-E-T-46: Application of a Twin-Detector Method for the Determination of the Mean Photon Energy Em at Points of Measurement in a Water Phantom Surrounding a GammaMed HDR 192Ir Brachytherapy Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chofor, N; Poppe, B; Nebah, F

    Purpose: In a brachytherapy photon field in water the fluence-averaged mean photon energy Em at the point of measurement correlates with the radiation quality correction factor kQ of a non water-equivalent detector. To support the experimental assessment of Em, we show that the normalized signal ratio NSR of a pair of radiation detectors, an unshielded silicon diode and a diamond detector can serve to measure quantity Em in a water phantom at a Ir-192 unit. Methods: Photon fluence spectra were computed in EGSnrc based on a detailed model of the GammaMed source. Factor kQ was calculated as the ratio ofmore » the detector's spectrum-weighted responses under calibration conditions at a 60Co unit and under brachytherapy conditions at various radial distances from the source. The NSR was investigated for a pair of a p-type unshielded silicon diode 60012 and a synthetic single crystal diamond detector 60019 (both PTW Freiburg). Each detector was positioned according to its effective point of measurement, with its axis facing the source. Lateral signal profiles were scanned under complete scatter conditions, and the NSR was determined as the quotient of the signal ratio under application conditions x and that at position r-ref = 1 cm. Results: The radiation quality correction factor kQ shows a close correlation with the mean photon energy Em. The NSR of the diode/diamond pair changes by a factor of two from 0–18 cm from the source, while Em drops from 350 to 150 keV. Theoretical and measured NSR profiles agree by ± 2 % for points within 5 cm from the source. Conclusion: In the presence of the close correlation between radiation quality correction factor kQ and photon mean energy Em, the NSR provides a practical means of assessing Em under clinical conditions. Precise detector positioning is the major challenge.« less

  7. Method for determining formation quality factor from seismic data

    DOEpatents

    Taner, M. Turhan; Treitel, Sven

    2005-08-16

    A method is disclosed for calculating the quality factor Q from a seismic data trace. The method includes calculating a first and a second minimum phase inverse wavelet at a first and a second time interval along the seismic data trace, synthetically dividing the first wavelet by the second wavelet, Fourier transforming the result of the synthetic division, calculating the logarithm of this quotient of Fourier transforms and determining the slope of a best fit line to the logarithm of the quotient.

  8. Physics of Bodily Tides in Terrestrial Planets and the Appropriate Scales of Dynamical Evolution

    DTIC Science & Technology

    2007-12-29

    ORGANIZATION NAME(S) AND ADDRESS(ES) U.S. Naval Observatory ,3450 Massachusetts Ave,Washington,DC,20392-5420 8. PERFORMING ORGANIZATION REPORT NUMBER 9...circumstances only the principal tidal frequency (4) will matter . 2. Quality Factor Q and the Geometric Lag Angle d [7] During tidal flexure, the...correct. The inaccuracy in notations has not prevented Bills et al. [2005] from arriving at a reasonable value of the Martian quality factor, 85.58 ± 0.37

  9. A Novel Symmetrical Split Ring Resonator Based on Microstrip for Microwave Sensors

    NASA Astrophysics Data System (ADS)

    Alahnomi, Rammah A.; Zakaria, Z.; Ruslan, E.; Bahar, Amyrul Azuan Mohd

    2016-02-01

    In this paper, novel symmetrical split ring resonator (SSRR) is proposed as a suitable component for performance enhancement of microwave sensors. SSRR has been employed for enhancing the insertion loss of the microwave sensors. Using the same device area, we can achieve a high Q-factor of 141.54 from the periphery enhancement using Quasi-linear coupling SSRR, whereas loose coupling SSRR can achieve a Q-factor of 33.98 only. Using Quasi-linear coupling SSRR, the Q-factor is enhanced 4.16 times the loose coupling SSRR using the same device area. After the optimization was made, the SSRR sensor with loose coupling scheme has achieved a very high Qfactor value around 407.34 while quasi-linear scheme has achieved high Q-factor value of 278.78 at the same operating frequency with smaller insertion loss. Spurious passbands at 1st, 2nd, 3rd, and 4th harmonics have been completely suppressed well above -20 dB rejection level without visible changes in the passband filter characteristics. The most significant of using SSRR is to be used for various industrial applications such as food industry, quality control, bio-sensing medicine and pharmacy. The simulation result that Quasi-linear coupling SSRR is a viable candidate for the performance enhancement of microwave sensors has been verified.

  10. Q-controlled amplitude modulation atomic force microscopy in liquids: An analysis

    NASA Astrophysics Data System (ADS)

    Hölscher, H.; Schwarz, U. D.

    2006-08-01

    An analysis of amplitude modulation atomic force microscopy in liquids is presented with respect to the application of the Q-Control technique. The equation of motion is solved by numerical and analytic methods with and without Q-Control in the presence of a simple model interaction force adequate for many liquid environments. In addition, the authors give an explicit analytical formula for the tip-sample indentation showing that higher Q factors reduce the tip-sample force. It is found that Q-Control suppresses unwanted deformations of the sample surface, leading to the enhanced image quality reported in several experimental studies.

  11. Q-values for P and S waves in Southern Sinai and Southern Gulf of Suez Region, Egypt

    NASA Astrophysics Data System (ADS)

    Mohamed, Gad-Elkareem A.

    2014-05-01

    The quality factor Q has been estimated using spectral amplitudes of P and S waves from earthquakes recorded by the seismic network of the Egyptian National Seismological Network (ENSN) in southern Sinai and southern Gulf of Suez region. The earthquakes recorded at nine stations - DHA, NUB, TR1, TR2, KAT, SH2, GRB, HRG and SFG have been used in this study. The spectral amplitude ratios have been calculated between 2 - 20 Hz and single station spectral ratio method has been applied for this purpose. The results show that the quality factors for both P and S waves (Qp and Qs) increase as a function of frequency according to law the Q = Q0fn. By averaging the estimated Q- Value obtained at all stations we calculated the average attenuation laws: Qp = (13.15± 0.76) f0.95± 0.19 and Qs = (20.05± 0.79) f1.03±0.04 for P and S waves respectively. These relations are useful for the estimation of source parameters of earthquakes and simulation of earthquake strong ground motions. The QS /QP ratio for KAT station is less than 1 at lower frequencies, whereas at HRG and SH2 stations QS /QP ratio is are greater than 1.

  12. High-Q Wafer Level Package Based on Modified Tri-Layer Anodic Bonding and High Performance Getter and Its Evaluation for Micro Resonant Pressure Sensor.

    PubMed

    Wang, Liying; Du, Xiaohui; Wang, Lingyun; Xu, Zhanhao; Zhang, Chenying; Gu, Dandan

    2017-03-16

    In order to achieve and maintain a high quality factor (high-Q) for the micro resonant pressure sensor, this paper presents a new wafer level package by adopting cross-layer anodic bonding technique of the glass/silicon/silica (GSS) stackable structure and integrated Ti getter. A double-layer structure similar to a silicon-on-insulator (SOI) wafer is formed after the resonant layer and the pressure-sensitive layer are bonded by silicon direct bonding (SDB). In order to form good bonding quality between the pressure-sensitive layer and the glass cap layer, the cross-layer anodic bonding technique is proposed for vacuum package by sputtering Aluminum (Al) on the combination wafer of the pressure-sensitive layer and the resonant layer to achieve electrical interconnection. The model and the bonding effect of this technique are discussed. In addition, in order to enhance the performance of titanium (Ti) getter, the prepared and activation parameters of Ti getter under different sputtering conditions are optimized and discussed. Based on the optimized results, the Ti getter (thickness of 300 nm to 500 nm) is also deposited on the inside of the glass groove by magnetron sputtering to maintain stable quality factor (Q). The Q test of the built testing system shows that the number of resonators with a Q value of more than 10,000 accounts for more than 73% of the total. With an interval of 1.5 years, the Q value of the samples remains almost constant. It proves the proposed cross-layer anodic bonding and getter technique can realize high-Q resonant structure for long-term stable operation.

  13. Simultaneous excitation of extremely high-Q-factor trapped and octupolar modes in terahertz metamaterials.

    PubMed

    Yang, Shengyan; Tang, Chengchun; Liu, Zhe; Wang, Bo; Wang, Chun; Li, Junjie; Wang, Li; Gu, Changzhi

    2017-07-10

    Achieving high-Q-factor resonances allows dramatic enhancement of performance of many plasmonic devices. However, the excitation of high-Q-factor resonance, especially multiple high-Q-factor resonances, has been a big challenge in traditional metamaterials due to the ohmic and radiation losses. Here, we experimentally demonstrate simultaneous excitation of double extremely sharp resonances in a terahertz metamaterial composed of mirror-symmetric-broken double split ring resonators (MBDSRRs). In a regular mirror-arranged SRR array, only the low-Q-factor dipole resonance can be excited with the external electric field perpendicular to the SRR gap. Breaking the mirror-symmetry of the metamaterial leads to the occurrence of two distinct otherwise inaccessible ultrahigh-Q-factor modes, which consists of one trapped mode in addition to an octupolar mode. By tuning the asymmetry parameter, the Q factor of the trapped mode can be linearly modulated, while the Q factor of the octupolar mode can be tailored exponentially. For specific degree of asymmetry, our simulations revealed a significantly high Q factor (Q>100) for the octupolar mode, which is more than one order of magnitude larger than that of conventional metamaterials. The mirror-symmetry-broken metamaterial offers the advantage of enabling access to two distinct high-Q-factor resonances which could be exploited for ultrasensitive sensors, multiband filters, and slow light devices.

  14. Knudsen pump produced via silicon deep RIE, thermal oxidation, and anodic bonding processes for on-chip vacuum pumping

    NASA Astrophysics Data System (ADS)

    Van Toan, Nguyen; Inomata, Naoki; Trung, Nguyen Huu; Ono, Takahito

    2018-05-01

    This work describes the fabrication and evaluation of the Knudsen pump for on-chip vacuum pumping that works based on the principle of a thermal transpiration. Three AFM (atomic force microscope) cantilevers are integrated into small chambers with a size of 5 mm  ×  3 mm  ×  0.4 mm for the pump’s evaluation. Knudsen pump is fabricated using deep RIE (reactive ion etching), wet thermal oxidation and anodic bonding processes. The fabricated device is evaluated by monitoring the quality (Q) factor of the integrated cantilevers. The Q factor of the cantilever is increased from 300 -1150 in cases without and with a temperature difference approximately 25 °C between the top (the hot side at 40 °C) and bottom (the cold side at 15 °C) sides of the fabricated device, respectively. The evacuated chamber pressure of around 10 kPa is estimated from the Q factor of the integrated cantilevers.

  15. Polarization-dependent electromagnetic responses of ultrathin and highly flexible asymmetric terahertz metasurfaces

    NASA Astrophysics Data System (ADS)

    Burrow, Joshua A.; Yahiaoui, Riad; Sarangan, Andrew; Agha, Imad; Mathews, Jay; Searles, Thomas A.

    2017-12-01

    We report the polarization-dependent electromagnetic response from a series of novel terahertz (THz) metasurfaces where asymmetry is introduced through the displacement of two adjacent metallic arms separated by a distance $\\delta$. For all polarization states, the symmetric metasurface exhibits a low quality (Q) factor fundamental dipole mode. By breaking the symmetry, we experimentally observe a secondary dipole-like mode with a Q factor nearly $9\\times$ higher than the fundamental resonance. As $\\delta$ increases, the fundamental dipole mode $f_{1}$ redshifts and the secondary mode $f_{2}$ blueshifts creating a highly transmissive spectral window. Polarization-dependent measurements reveal a full suppression of $f_{2}$ for all asymmetries at $\\theta \\geq 60^\\circ$. Furthermore, at $\\delta \\geq 60 \\text{ }\\mu\\text{m}$, we observe a polarization selective electromagnetic induced transparency (EIT) for the fundamental mode. This work paves the way for applications in filtering, sensing and slow-light devices common to other high Q factor THz metasurfaces with EIT-like response.

  16. Excitation of hypersonic acoustic waves in diamond-based piezoelectric layered structure on the microwave frequencies up to 20GHz.

    PubMed

    Sorokin, B P; Kvashnin, G M; Novoselov, A S; Bormashov, V S; Golovanov, A V; Burkov, S I; Blank, V D

    2017-07-01

    First ultrahigh frequency (UHF) investigation of quality factor Q for the piezoelectric layered structure «Al/(001)AlN/Mo/(100) diamond» has been executed in a broad frequency band from 1 up to 20GHz. The record-breaking Q·f quality parameter up to 2.7·10 14 Hz has been obtained close to 20GHz. Frequency dependence of the form factor m correlated with quality factor has been analyzed by means of computer simulation, and non-monotonic frequency dependence can be explained by proper features of thin-film piezoelectric transducer (TFPT). Excluding the minimal Q magnitudes measured at the frequency points associated with minimal TFPT effectiveness, one can prove a rule of Qf∼f observed for diamond on the frequencies above 1GHz and defined by Landau-Rumer's acoustic attenuation mechanism. Synthetic IIa-type diamond single crystal as a substrate material for High-overtone Bulk Acoustic Resonator (HBAR) possesses some excellent acoustic properties in a wide microwave band and can be successfully applied for design of acoustoelectronic devices, especially the ones operating at a far UHF band. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Morphology-dependent resonances of a microsphere-optical fiber system

    NASA Astrophysics Data System (ADS)

    Griffel, Giora; Arnold, Stephen; Taskent, Dogan; Serpengüzel, Ali; Connolly, John; Morris, Nancy

    1996-05-01

    Morphology-dependent resonances of microspheres sitting upon an index-matched single-mode fiber half-coupler are excited by a tunable 753-nm distributed-feedback laser. Resonance peaks in the scattering spectra and associated dips in the transmission spectra for the TE and TM modes are observed. We present a new model that describes this interaction in terms of the fiber-sphere coupling coefficient and the microsphere's intrinsic quality factor Q0 . This model enables us to obtain expressions for the finesse and the Q factor of the composite particle-fiber system, the resonance width, and the depth of the dips measured in the transmission spectra. Our model shows that index matching improves the coupling efficiency by more than a factor of 2 compared with that of a non-index-matched system.

  18. Morphology-dependent resonances of a microsphere-optical fiber system.

    PubMed

    Griffel, G; Arnold, S; Taskent, D; Serpengüzel, A; Connolly, J; Morris, N

    1996-05-15

    Morphology-dependent resonances of microspheres sitting upon an index-matched single-mode fiber half-coupler are excited by a tunable 753-nm distributed-feedback laser. Resonance peaks in the scattering spectra and associated dips in the transmission spectra for the TE and TM modes are observed. We present a new model that describes this interaction in terms of the fiber-sphere coupling coefficient and the microsphere's intrinsic quality factor Q(0). This model enables us to obtain expressions for the finesse and the Q factor of the composite particle-fiber system, the resonance width, and the depth of the dips measured in the transmission spectra. Our model shows that index matching improves the coupling efficiency by more than a factor of 2 compared with that of a non-index-matched system.

  19. Cleaning procedure for improved photothermal background of toroidal optical microresonators

    NASA Astrophysics Data System (ADS)

    Horak, Erik H.; Knapper, Kassandra A.; Heylman, Kevin D.; Goldsmith, Randall H.

    2016-09-01

    High Q-factors and small mode volumes have made toroidal optical microresonators exquisite sensors to small shifts in the effective refractive index of the WGM modes. Eliminating contaminants and improving quality factors is key for many different sensing techniques, and is particularly important for photothermal imaging as contaminants add photothermal background obscuring objects of interest. Several different cleaning procedures including wet- and dry-chemical procedures are tested for their effect on Q-factors and photothermal background. RCA cleaning was shown to be successful in contrast to previously described acid cleaning procedures, most likely due to the different surface reactivity of the acid reagents used. UV-ozone cleaning was shown to be vastly superior to O2 plasma cleaning procedures, significantly reducing the photothermal background of the resonator.

  20. Shielded microstrip array for 7T human MR imaging.

    PubMed

    Wu, Bing; Wang, Chunsheng; Kelley, Douglas A C; Xu, Duan; Vigneron, Daniel B; Nelson, Sarah J; Zhang, Xiaoliang

    2010-01-01

    The high-frequency transceiver array based on the microstrip transmission line design is a promising technique for ultrahigh field magnetic resonance imaging (MRI) signal excitation and reception. However, with the increase of radio-frequency (RF) channels, the size of the ground plane in each microstrip coil element is usually not sufficient to provide a perfect ground. Consequently, the transceiver array may suffer from cable resonance, lower Q-factors, and imaging quality degradations. In this paper, we present an approach to improving the performance of microstrip transceiver arrays by introducing RF shielding outside the microstrip array and the feeding coaxial cables. This improvement reduced interactions among cables, increased resonance stability, and Q-factors, and thus improved imaging quality. An experimental method was also introduced and utilized for quantitative measurement and evaluation of RF coil resonance stability or "cable resonance" behavior.

  1. Shielded Microstrip Array for 7T Human MR Imaging

    PubMed Central

    Wu, Bing; Wang, Chunsheng; Kelley, Douglas A. C.; Xu, Duan; Vigneron, Daniel B.; Nelson, Sarah J.

    2010-01-01

    The high-frequency transceiver array based on the microstrip transmission line design is a promising technique for ultrahigh field magnetic resonance imaging (MRI) signal excitation and reception. However, with the increase of radio-frequency (RF) channels, the size of the ground plane in each microstrip coil element is usually not sufficient to provide a perfect ground. Consequently, the transceiver array may suffer from cable resonance, lower Q-factors, and imaging quality degradations. In this paper, we present an approach to improving the performance of microstrip transceiver arrays by introducing RF shielding outside the microstrip array and the feeding coaxial cables. This improvement reduced interactions among cables, increased resonance stability, and Q-factors, and thus improved imaging quality. An experimental method was also introduced and utilized for quantitative measurement and evaluation of RF coil resonance stability or “cable resonance” behavior. PMID:19822470

  2. Acoustic properties of a crack containing magmatic or hydrothermal fluids

    USGS Publications Warehouse

    Kumagai, H.; Chouet, B.A.

    2000-01-01

    We estimate the acoustic properties of a crack containing maginatic or hydrothermal fluids to quantify the source properties of long-period (LP) events observed in volcanic areas assuming that a crack-like structure is the source of LP events. The tails of synthetic waveforms obtained from a model of a fluid-driven crack are analyzed by the Sompi method to determine the complex frequencies of one of the modes of crack resonance over a wide range of the model parameters ??/a and ??f/??s, where ?? is the P wave velocity of the rock matrix, a is the sound speed of the fluid, and ??f and ??s are the densities of the fluid and rock matrix, respectively. The quality factor due to radiation loss (Qr) for the selected mode almost monotonically increases with increasing ??/a, while the dimensionless frequency (??) of the mode decreases with increasing ??/a and ??f/??s. These results are used to estimate Q and ?? for a crack containing various types of fluids (gas-gas mixtures, liquid-gas mixtures, and dusty and misty gases) for values of a, ??f, and quality factor due to intrinsic losses (Qi) appropriate for these types of fluids, in which Q is given by Q-1 = Qr-1 + Qi-1. For a crack containing such fluids, we obtain Q ranging from almost unity to several hundred, which consistently explains the wide variety of quality factors measured in LP events observed at various volcanoes. We underscore the importance of dusty and misty gases containing small-size particles with radii around 1 ??m to explain long-lasting oscillations with Q significantly larger than 100. Our results may provide a basis for the interpretation of spatial and temporal variations in the observed complex frequencies of LP events in terms of fluid compositions beneath volcanoes. Copyright 2000 by the American Geophysical Union.

  3. Design of primers and probes for quantitative real-time PCR methods.

    PubMed

    Rodríguez, Alicia; Rodríguez, Mar; Córdoba, Juan J; Andrade, María J

    2015-01-01

    Design of primers and probes is one of the most crucial factors affecting the success and quality of quantitative real-time PCR (qPCR) analyses, since an accurate and reliable quantification depends on using efficient primers and probes. Design of primers and probes should meet several criteria to find potential primers and probes for specific qPCR assays. The formation of primer-dimers and other non-specific products should be avoided or reduced. This factor is especially important when designing primers for SYBR(®) Green protocols but also in designing probes to ensure specificity of the developed qPCR protocol. To design primers and probes for qPCR, multiple software programs and websites are available being numerous of them free. These tools often consider the default requirements for primers and probes, although new research advances in primer and probe design should be progressively added to different algorithm programs. After a proper design, a precise validation of the primers and probes is necessary. Specific consideration should be taken into account when designing primers and probes for multiplex qPCR and reverse transcription qPCR (RT-qPCR). This chapter provides guidelines for the design of suitable primers and probes and their subsequent validation through the development of singlex qPCR, multiplex qPCR, and RT-qPCR protocols.

  4. An improved peak frequency shift method for Q estimation based on generalized seismic wavelet function

    NASA Astrophysics Data System (ADS)

    Wang, Qian; Gao, Jinghuai

    2018-02-01

    As a powerful tool for hydrocarbon detection and reservoir characterization, the quality factor, Q, provides useful information in seismic data processing and interpretation. In this paper, we propose a novel method for Q estimation. The generalized seismic wavelet (GSW) function was introduced to fit the amplitude spectrum of seismic waveforms with two parameters: fractional value and reference frequency. Then we derive an analytical relation between the GSW function and the Q factor of the medium. When a seismic wave propagates through a viscoelastic medium, the GSW function can be employed to fit the amplitude spectrum of the source and attenuated wavelets, then the fractional values and reference frequencies can be evaluated numerically from the discrete Fourier spectrum. After calculating the peak frequency based on the obtained fractional value and reference frequency, the relationship between the GSW function and the Q factor can be built by the conventional peak frequency shift method. Synthetic tests indicate that our method can achieve higher accuracy and be more robust to random noise compared with existing methods. Furthermore, the proposed method is applicable to different types of source wavelet. Field data application also demonstrates the effectiveness of our method in seismic attenuation and the potential in the reservoir characteristic.

  5. MicroElectroMechanical devices and fabrication technologies for radio-frequency analog signal processing

    NASA Astrophysics Data System (ADS)

    Young, Darrin Jun

    The proliferation of wireless services creates a pressing need for compact and low cost RF transceivers. Modern sub-micron technologies provide the active components needed for miniaturization but fail to deliver high quality passives needed in oscillators and filters. This dissertation demonstrates procedures for adding high quality inductors and tunable capacitors to a standard silicon integrated circuits. Several voltage-controlled oscillators operating in the low Giga-Hertz range demonstrate the suitability of these components for high performance RF building blocks. Two low-temperature processes are described to add inductors and capacitors to silicon ICs. A 3-D coil geometry is used for the inductors rather than the conventional planar spiral to substantially reduce substrate loss and hence improve the quality factor and self-resonant frequency. Measured Q-factors at 1 GHz are 30 for a 4.8 nH device, 16 for 8.2 nH and 13.8 nH inductors. Several enhancements are proposed that are expected to result in a further improvement of the achievable Q-factor. This research investigates the design and fabrication of silicon-based IC-compatible high-Q tunable capacitors and inductors. The goal of this investigation is to develop a monolithic low phase noise radio-frequency voltage-controlled oscillator using these high-performance passive components for wireless communication applications. Monolithic VCOs will help the miniaturization of current radio transceivers, which offers a potential solution to achieve a single hand-held wireless phone with multistandard capabilities. IC-compatible micromachining fabrication technologies have been developed to realize on-chip high-Q RF tunable capacitors and 3-D coil inductors. The capacitors achieve a nominal capacitance value of 2 pF and can be tuned over 15% with 3 V. A quality factor over 60 has been measured at 1 GHz. 3-D coil inductors obtain values of 4.8 nH, 8.2 nH and 13.8 nH. At 1 GHz a Q factor of 30 has been achieved for a 4.8 nH device and a Q of 16 for 8.2 nH and 13.8 nH inductors. A prototype RF voltage-controlled oscillator has been implemented employing the micromachined tunable capacitors and a 8.2 nH 3-D coil inductor. The active electronics, tunable capacitors and inductor are fabricated on separated silicon substrates and wire bonded to form the VCO. This hybrid approach is used to avoid the complexity of building the prototype oscillator. Both passive components are fabricated on silicon substrates and thus amenable to monolithic integration with standard IC process. The VCO achieves a -136 dBc/Hz phase noise at a 3 MHz offset frequency from the carrier, suitable for most wireless communication applications and is tunable from 855 MHz to 863 MHz with 3 V.

  6. High-Q, in-plane modes of nanomechanical resonators operated in air

    NASA Astrophysics Data System (ADS)

    Waggoner, Philip S.; Tan, Christine P.; Bellan, Leon; Craighead, Harold G.

    2009-05-01

    Nanomechanical resonators have traditionally been limited to use in vacuum due to low quality factors that come as a result of viscous damping effects in air or liquid. We have fabricated arrays of 90 nm thick trampoline-shaped resonators, studied their resonant frequency spectrum as a function of pressure, and found that some high frequency modes exhibit quality factors over 2000 at atmospheric pressure. We have excited the in-plane resonances of these devices, verified their identities both experimentally and with finite element modeling, and demonstrated their advantageous characteristics for ambient sensing. Even after deposition of a relatively thick polymer layer, the in-plane resonant modes still boast quality factors on the order of 2000. These results show promise for the use of nanomechanical resonant sensors in real-time atmospheric sensing applications.

  7. Temperature and frequency dependence of anelasticity in a nickel oscillator

    NASA Astrophysics Data System (ADS)

    Berg, Robert F.

    1995-09-01

    The frequency dependence of the real and imaginary parts of a nickel oscillator's transfer function is described over 3 decades in frequency by the use of simple expressions. These expressions incorporate only the resonance frequency ω0, the quality factor Q, and a characteristic exponent β determined by a single measurement of creep. They are based on the ansatz φ(ω)=Q-1(ω/ω0)-β, where φ is the imaginary part of the spring constant. Over a 100 K range of temperature T, the exponent β≂0.18 was constant even though Q(T) changed by a factor of 8. These expressions are potentially useful for accurately describing a mechanical oscillator whose transfer function must be modeled at frequencies far below ω0. Examples include accelerometers based on a flexure element and suspensions for interferometric gravitational wave detectors.

  8. Chaperones in Polyglutamine Aggregation: Beyond the Q-Stretch

    PubMed Central

    Kuiper, E. F. E.; de Mattos, Eduardo P.; Jardim, Laura B.; Kampinga, Harm H.; Bergink, Steven

    2017-01-01

    Expanded polyglutamine (polyQ) stretches in at least nine unrelated proteins lead to inherited neuronal dysfunction and degeneration. The expansion size in all diseases correlates with age at onset (AO) of disease and with polyQ protein aggregation, indicating that the expanded polyQ stretch is the main driving force for the disease onset. Interestingly, there is marked interpatient variability in expansion thresholds for a given disease. Between different polyQ diseases the repeat length vs. AO also indicates the existence of modulatory effects on aggregation of the upstream and downstream amino acid sequences flanking the Q expansion. This can be either due to intrinsic modulation of aggregation by the flanking regions, or due to differential interaction with other proteins, such as the components of the cellular protein quality control network. Indeed, several lines of evidence suggest that molecular chaperones have impact on the handling of different polyQ proteins. Here, we review factors differentially influencing polyQ aggregation: the Q-stretch itself, modulatory flanking sequences, interaction partners, cleavage of polyQ-containing proteins, and post-translational modifications, with a special focus on the role of molecular chaperones. By discussing typical examples of how these factors influence aggregation, we provide more insight on the variability of AO between different diseases as well as within the same polyQ disorder, on the molecular level. PMID:28386214

  9. Travelling wave resonators fabricated with low-loss hydrogenated amorphous silicon

    NASA Astrophysics Data System (ADS)

    Lipka, Timo; Amthor, Julia; Trieu, Hoc Khiem; Müller, Jörg

    2013-05-01

    Low-loss hydrogenated amorphous silicon is employed for the fabrication of various planar integrated travelling wave resonators. Microring, racetrack, and disk resonators of different dimensions were fabricated with CMOS-compatible processes and systematically investigated. The key properties of notch filter ring resonators as extinction ratio, Q-factor, free spectral range, and the group refractive index were determined for resonators of varying radius, thereby achieving critically coupled photonic systems with high extinction ratios of about 20 dB for both polarizations. Racetrack resonators that are arranged in add/drop configuration and high quality factor microdisk resonators were optically characterized, with the microdisks exhibiting Q-factors of greater than 100000. Four-channel add/drop wavelength-division multiplexing filters that are based on cascaded racetrack resonators are studied. The design, the fabrication, and the optical characterization are presented.

  10. New set of design rules for resonant refractive index sensors enabled by FFT based processing of the measurement data.

    PubMed

    Gounaridis, Lefteris; Groumas, Panos; Schreuder, Erik; Heideman, Rene; Avramopoulos, Hercules; Kouloumentas, Christos

    2016-04-04

    It is still a common belief that ultra-high quality-factors (Q-factors) are a prerequisite in optical resonant cavities for high refractive index resolution and low detection limit in biosensing applications. In combination with the ultra-short steps that are necessary when the measurement of the resonance shift relies on the wavelength scanning of a laser source and conventional methods for data processing, the high Q-factor requirement makes these biosensors extremely impractical. In this work we analyze an alternative processing method based on the fast-Fourier transform, and show through Monte-Carlo simulations that improvement by 2-3 orders of magnitude can be achieved in the resolution and the detection limit of the system in the presence of amplitude and spectral noise. More significantly, this improvement is maximum for low Q-factors around 104 and is present also for high intra-cavity losses and large scanning steps making the designs compatible with the low-cost aspect of lab-on-a-chip technology. Using a micro-ring resonator as model cavity and a system design with low Q-factor (104), low amplitude transmission (0.85) and relatively large scanning step (0.25 pm), we show that resolution close to 0.01 pm and detection limit close to 10-7 RIU can be achieved improving the sensing performance by more than 2 orders of magnitude compared to the performance of systems relying on a simple peak search processing method. The improvement in the limit of detection is present even when the simple method is combined with ultra-high Q-factors and ultra-short scanning steps due to the trade-off between the system resolution and sensitivity. Early experimental results are in agreement with the trends of the numerical studies.

  11. Influence of growing altitude, shade and harvest period on quality and biochemical composition of Ethiopian specialty coffee.

    PubMed

    Tolessa, Kassaye; D'heer, Jolien; Duchateau, Luc; Boeckx, Pascal

    2017-07-01

    Coffee quality is a key characteristic for the international market, comprising cup quality and chemical bean constituents. In Ethiopia, using total specialty cup scores, coffees are grouped into Q1 (specialty 1) ≥ 85 and Q2 (80-84.75). This classification results in market segmentation and higher prices. Although different studies have evaluated the effects of altitude and shade on bean quality, optimum shade levels along different altitudinal ranges are not clearly indicated. Information on effects of harvest periods on coffee quality is also scanty. The present study examined the influences of these factors and their interactions on Ethiopian coffee quality RESULTS: Coffee from high altitude with open or medium shade and early to middle harvest periods had a superior bean quality. These growing conditions also favoured the production of beans with lower caffeine. An increasing altitude, from mid to high, at approximately 400 m, decreased caffeine content by 10%. At high altitude, dense shade decreased Q1 coffee by 50%. Compared to late harvesting, early harvesting increased the percentage from 27% to 73%. At mid altitude, > 80% is Q2 coffee. Changes of quality scores driven by altitude, shade and harvest period are small, although they may induce dramatic switches in the fraction Q1 versus Q2 coffee. The latter affects both farmers' profits and competitiveness in international markets. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  12. [Confusing the confused: thoughts on impact factor, h(irsch) index, Q value, and other cofactors that influence the researcher's happiness].

    PubMed

    Quindós, Guillermo

    2009-06-30

    The need to evaluate curricula for sponsorship for research projects or professional promotion, has led to the search for tools that allow an objective valuation. However, the total number papers published, or citations of articles of a particular author, or the impact factor of the Journal where they are published are inadequate indicators for the evaluation of the quality and productivity of researchers. The h index, proposed by Hirsch, categorises the papers according to the number of citations per article. This tool appears to lack the limitations of other bibliometric tools but is less useful for non English-speaking authors. To propose and debate the usefulness of the existing bibliometric indicators and tools for the evaluation and categorization of researchers and scientific journals. Search for papers on bibliometric tools. There are some hot spots in the debate on the national and international evaluation of researchers' productivity and quality of scientific journals. Opinions on impact factors and h index have been discussed. The positive discrimination, using the Q value, is proposed as an alternative for the evaluation of Spanish and Iberoamerican researchers. It is very important de-mystify the importance of bibliometric indicators. The impact factor is useful for evaluating journals from the same scientific area but not for the evaluation of researchers' curricula. For the comparison of curricula from two or more researchers, we must use the h index or the proposed Q value. the latter allows positive discrimination of the task for Spanish and Iberoamerican researchers.

  13. Analysis and optimization of acoustic wave micro-resonators integrating piezoelectric zinc oxide layers

    NASA Astrophysics Data System (ADS)

    Mortada, O.; Zahr, A. H.; Orlianges, J.-C.; Crunteanu, A.; Chatras, M.; Blondy, P.

    2017-02-01

    This paper reports on the design, simulation, fabrication, and test results of ZnO-based contour-mode micro-resonators integrating piezoelectric zinc oxide (ZnO) layers. The inter-digitated (IDT) type micro-resonators are fabricated on ZnO films and suspended top of 2 μm thick silicon membranes using silicon-on insulator technology. We analyze several possibilities of increasing the quality factor (Q) and the electromechanical coupling coefficient (kt2) of the devices by varying the numbers and lengths of the IDT electrodes and using different thicknesses of the ZnO layer. We designed and fabricated IDTs of different finger numbers (n = 25, 40, 50, and 80) and lengths (L = 100/130/170/200 μm) for three different thicknesses of ZnO films (200, 600, and 800 nm). The measured Q factor confirms that reducing the length and the number of IDT fingers enables us to reach better electrical performances at resonant frequencies around 700 MHz. The extracted results for an optimized micro-resonator device having an IDT length of 100 μm and 40 finger electrodes show a Q of 1180 and a kt2 of 7.4%. We demonstrate also that the reduction of the ZnO thickness from 800 nm to 200 nm increases the quality factor from 430 to 1600, respectively, around 700 MHz. Experimental data are in very good agreement with theoretical simulations of the fabricated devices

  14. High-Q lattice mode matched structural resonances in terahertz metasurfaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Ningning; Zhang, Weili, E-mail: weili.zhang@okstate.edu; Singh, Ranjan, E-mail: ranjans@ntu.edu.sg

    2016-07-11

    The quality (Q) factor of metamaterial resonances is limited by the radiative and non-radiative losses. At terahertz frequencies, the dominant loss channel is radiative in nature since the non-radiative losses are low due to high conductivity of metals. Radiative losses could be suppressed by engineering the meta-atom structure. However, such suppression usually occurs at the fundamental resonance mode which is typically a closed mode resonance such as an inductive-capacitive resonance or a Fano resonance. Here, we report an order of magnitude enhancement in Q factor of all the structural eigenresonances of a split-ring resonator fueled by the lattice mode matching.more » We match the fundamental order diffractive mode to each of the odd and even eigenresonances, thus leading to a tremendous line-narrowing of all the resonances. Such precise tailoring and control of the structural resonances in a metasurface lattice could have potential applications in low-loss devices, sensing, and design of high-Q metamaterial cavities.« less

  15. Study of thermally-induced optical bistability and the role of surface treatments in Si-based mid-infrared photonic crystal cavities.

    PubMed

    Shankar, Raji; Bulu, Irfan; Leijssen, Rick; Lončar, Marko

    2011-11-21

    We report the observation of optical bistability in Si-based photonic crystal cavities operating around 4.5 µm. Time domain measurements indicate that the source of this optical bistability is thermal, with a time constant on the order of 5 µs. Quality (Q) factor improvement is shown by the use of surface treatments (wet processes and annealing), resulting in a significant increase in Q-factor, which in our best devices is on the order of ~45,000 at 4.48 µm. After annealing in a N(2) environment, optical bistability is no longer seen in our cavities. © 2011 Optical Society of America

  16. Thermoelastic damping effect of the micro-ring resonator with irregular mass and stiffness

    NASA Astrophysics Data System (ADS)

    Kim, Jung-Hwan; Kim, Ji-Hwan

    2016-05-01

    Fundamentally, vibration characteristic is a main factor for the stability of structures. In this regard, the irregularity of mass and stiffness distributions for the structure have been an interesting issue for many years. Recently, the Micro Electro Mechanical Systems (MEMS) are developed for various applications such as gyro sensors. In the present work, in-plane vibration of micro-ring structure with multiple finite-sized imperfections is investigated. Then, the unbalance of the structure is represented using Heaviside Step Function for the inextensional modeling of the ring. Also, thermoelastic damping (TED) due to internal friction is studied based on Fourier's one-dimensional heat conduction equation using Laplace Transform. To obtain the quality-factors (Q-factors) for imperfect micro-ring, analytical solutions are calculated from governing equations of motion with TED. And then, the natural frequencies and the Q-factors are observed to separate into lower and higher modes. Additionally, the vibration mode shapes are presented, and the frequency trimming concept due to attached imperfections is investigated.

  17. Microcavity morphology optimization

    NASA Astrophysics Data System (ADS)

    Ferdous, Fahmida; Demchenko, Alena A.; Vyatchanin, Sergey P.; Matsko, Andrey B.; Maleki, Lute

    2014-09-01

    High spectral mode density of conventional optical cavities is detrimental to the generation of broad optical frequency combs and to other linear and nonlinear applications. In this work we optimize the morphology of high-Q whispering gallery (WG) and Fabry-Perot (FP) cavities and find a set of parameters that allows treating them, essentially, as single-mode structures, thus removing limitations associated with a high density of cavity mode spectra. We show that both single-mode WGs and single-mode FP cavities have similar physical properties, in spite of their different loss mechanisms. The morphology optimization does not lead to a reduction of quality factors of modes belonging to the basic family. We study the parameter space numerically and find the region where the highest possible Q factor of the cavity modes can be realized while just having a single bound state in the cavity. The value of the Q factor is comparable with that achieved in conventional cavities. The proposed cavity structures will be beneficial for generation of octave spanning coherent frequency combs and will prevent undesirable effects of parametric instability in laser gravitational wave detectors.

  18. Children's perception on obesity and quality of life: a Mexican survey.

    PubMed

    Rendón-Macías, Mario-Enrique; Rosas-Vargas, Haydeé; Villasís-Keever, Miguel-Ángel; Pérez-García, Celia

    2014-05-29

    Child obesity has become a major health problem worldwide. In order to design successful intervention strategies, it is necessary to understand how children perceive obesity and its consequences. With the aim to evaluate scholar children perception of obesity as a significant factor on the quality of life, we developed and validated the "Obesity impact on the quality of life perception-questionnaire" (ObI-Q). We surveyed 1335 healthy children aged 6-12 years, randomly selected from elementary schools in Mexico City. The ObI-Q comprises eight multiple-choice items that explore aspects related to the quality of life during adult life; such as health, life span, emotional status, lifestyle, social recognition and economic status. In order to identify perceptional modifier factors, results were analyzed through multivariable logistic regression. Variables included gender, age, and child nutritional status, as well as the child's perception of parental nutritional status. ObI-Q results showed that most children (64.71%) considered obesity as a negative condition that influences health and social performance. This perception was inversely related to age (OR = 0.64, p = 0.003), as well as to the perception of their mother nutritional status (OR = 0.47, p = 0.01). This study provides an overview of children's perception on obesity and its consequences. Because the high proportion of schoolchildren who do not view obesity as an adverse consequence to the quality of life, then the results of this study could be used as part of strategies for the prevention of overweight and obesity.

  19. TH-CD-BRA-05: First Water Calorimetric Dw Measurement and Direct Measurement of Magnetic Field Correction Factors, KQ,B, in a 1.5 T B-Field of An MRI Linac

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prez, L de; Pooter, J de; Jansen, B

    2016-06-15

    Purpose: Reference dosimetry in MR-guided radiotherapy is performed in the presence of a B-field. As a consequence the response of ionization chambers changes considerably and depends on parameters not considered in traditional reference dosimetry. Therefore future Codes of Practices need ionization chamber correction factors to correct for both the change in beam quality and the presence of a B-field. The objective was to study the feasibility of water calorimetric absorbed-dose measurements in a 1.5 T B-field of an MRLinac and the direct measurement of kQ,B calibration of ionization chambers. Methods: Calorimetric absorbed dose to water Dw was measured with amore » new water calorimeter in the bore of an MRLinac (TPR20,10 of 0.702). Two waterproof ionization chambers (PTW 30013, IBA FC-65G) were calibrated inside the calorimeter phantom (ND,w,Q,B). Both measurements were normalized to a monitor ionization chamber. Ionization chamber measurements were corrected for conventional influence parameter. Based on the chambers’ Co-60 calibrations (ND,w,Q0), measured directly against the calorimeter. In this study the correction factors kQ,B was determined as the ratio of the calibration coefficients in the MRLinac and in Co-60. Additionally, kB was determined based on kQ values obtained with the IAEA TRS-398 Code of Practice. Results: The kQ,B factors of the ionization chambers mentioned above were respectively 0.9488(8) and 0.9445(8) with resulting kB factors of 0.961(13) and 0.952(13) with standard uncertainties on the least significant digit(s) between brackets. Conclusion: Calorimetric Dw measurements and calibration of waterproof ionization chambers were successfully carried out in the 1.5 T B-field of an MRLinac with a standard uncertainty of 0.7%. Preliminary kQ,B and kB factors were determined with standard uncertainties of respectively 0.8% and 1.3%. The kQ,B agrees with an alternative method within 0.4%. The feasibility of water calorimetry in the presence of B-fields was demonstrated by the direct determination of Dw and kQ,B. This work was supported by EMRP grant HLT06. The EMRP is jointly funded by the EMRP participating countries within EURAMET and the European Union.« less

  20. Systematic reviews and meta-analyses on psoriasis: role of funding sources, conflict of interest and bibliometric indices as predictors of methodological quality.

    PubMed

    Gómez-García, F; Ruano, J; Aguilar-Luque, M; Gay-Mimbrera, J; Maestre-Lopez, B; Sanz-Cabanillas, J L; Carmona-Fernández, P J; González-Padilla, M; Vélez García-Nieto, A; Isla-Tejera, B

    2017-06-01

    The quality of systematic reviews and meta-analyses on psoriasis, a chronic inflammatory skin disease that severely impairs quality of life and is associated with high costs, remains unknown. To assess the methodological quality of systematic reviews published on psoriasis. After a comprehensive search in MEDLINE, Embase and the Cochrane Database (PROSPERO: CDR42016041611), the quality of studies was assessed by two raters using the Assessment of Multiple Systematic Reviews (AMSTAR) tool. Article metadata and journal-related bibliometric indices were also obtained. Systematic reviews were classified as low (0-4), moderate (5-8) or high (9-11) quality. A prediction model for methodological quality was fitted using principal component and multivariate ordinal logistic regression analyses. We classified 220 studies as high (17·2%), moderate (55·0%) or low (27·8%) quality. Lower compliance rates were found for AMSTAR question (Q)5 (list of studies provided, 11·4%), Q10 (publication bias assessed, 27·7%), Q4 (status of publication included, 39·5%) and Q1 (a priori design provided, 40·9%). Factors such as meta-analysis inclusion [odds ratio (OR) 6·22; 95% confidence interval (CI) 2·78-14·86], funding by academic institutions (OR 2·90, 95% CI 1·11-7·89), Article Influence score (OR 2·14, 95% CI 1·05-6·67), 5-year impact factor (OR 1·34, 95% CI 1·02-1·40) and article page count (OR 1·08, 95% CI 1·02-1·15) significantly predicted higher quality. A high number of authors with a conflict of interest (OR 0·90, 95% CI 0·82-0·99) was significantly associated with lower quality. The methodological quality of systematic reviews published about psoriasis remains suboptimal. The type of funding sources and author conflicts may compromise study quality, increasing the risk of bias. © 2017 British Association of Dermatologists.

  1. Nursing home staff members' subjective frames of reference on residents' achievement of ego integrity: A Q-methodology study.

    PubMed

    Lim, Sun-Young; Chang, Sung-Ok

    2018-01-01

    To discover the structure of the frames of reference for nursing home staff members' subjective judgment of residents' achievement of ego integrity. Q-methodology was applied. Twenty-eight staff members who were working in a nursing home sorted 34 Q-statements into the shape of a normal distribution. A centroid factor analysis and varimax rotation, using the PQ-method program, revealed four factors: identifying clues to residents' positive acceptance of their whole life span, identifying residents' ways of enjoying their current life, referencing residents' attitudes and competencies toward harmonious relationships, and identifying residents' integrated efforts to establish self-esteem. These subjective frames of reference need to be investigated in order to improve the relationships with nursing home residents and their quality of life. Consequently, the fundamental monitoring tools to help staff members make subjective judgments can be formed. © 2017 Japan Academy of Nursing Science.

  2. High-Q photonic resonators and electro-optic coupling using silicon-on-lithium-niobate

    NASA Astrophysics Data System (ADS)

    Witmer, Jeremy D.; Valery, Joseph A.; Arrangoiz-Arriola, Patricio; Sarabalis, Christopher J.; Hill, Jeff T.; Safavi-Naeini, Amir H.

    2017-04-01

    Future quantum networks, in which superconducting quantum processors are connected via optical links, will require microwave-to-optical photon converters that preserve entanglement. A doubly-resonant electro-optic modulator (EOM) is a promising platform to realize this conversion. Here, we present our progress towards building such a modulator by demonstrating the optically-resonant half of the device. We demonstrate high quality (Q) factor ring, disk and photonic crystal resonators using a hybrid silicon-on-lithium-niobate material system. Optical Q factors up to 730,000 are achieved, corresponding to propagation loss of 0.8 dB/cm. We also use the electro-optic effect to modulate the resonance frequency of a photonic crystal cavity, achieving a electro-optic modulation coefficient between 1 and 2 pm/V. In addition to quantum technology, we expect that our results will be useful both in traditional silicon photonics applications and in high-sensitivity acousto-optic devices.

  3. Packaged microsphere-taper coupling system with a high Q factor.

    PubMed

    Dong, Yongchao; Wang, Keyi; Jin, Xueying

    2015-01-10

    A novel packaged microsphere-taper coupling system which consists of a glass tube and two glass plates is proposed and demonstrated in this paper. We analyze the impact of the microsphere distortion on the resonant spectrum and it is observed that a very high quality factor (Q) up to 1.08×10(8) can be achieved by optimizing the microsphere position and orientation relative to the fiber taper. The maintenance of Q and a stable spectrum are realized by placing the packaged structure in a sealed organic glass box. Furthermore, to verify the practicability of the sealed device, thermal sensing experiments are carried out, which indicates the excellent convenience of the device with a resolution of 1.12×10(-4)°C. The portability and robustness of the packaged structure make it strikingly attractive and illustrate its potential in practical microcavity sensors and lasers.

  4. Evanescent Microwave Probes on High-Resistivity Silicon and its Application in Characterization of Semiconductors

    NASA Technical Reports Server (NTRS)

    Tabib-Azar, M.; Akinwande, D.; Ponchak, George E.; LeClair, S. R.

    1999-01-01

    In this article we report the design, fabrication, and characterization of very high quality factor 10 GHz microstrip resonators on high-resistivity (high-rho) silicon substrates. Our experiments show that an external quality factor of over 13 000 can be achieved on microstripline resonators on high-rho silicon substrates. Such a high Q factor enables integration of arrays of previously reported evanescent microwave probe (EMP) on silicon cantilever beams. We also demonstrate that electron-hole pair recombination and generation lifetimes of silicon can be conveniently measured by illuminating the resonator using a pulsed light. Alternatively, the EMP was also used to nondestructively monitor excess carrier generation and recombination process in a semiconductor placed near the two-dimensional resonator.

  5. Properties of Superconducting Mo, Mo2n and Trilayer Mo2n-Mo-Mo2n Thin Films

    NASA Technical Reports Server (NTRS)

    Barrentine, E. M.; Stevenson, T. R.; Brown, A. D.; Lowitz, A. E.; Noroozian, O.; U-Yen, K.; Eshan, N.; Hsieh, W. T.; Moseley, S. H.; Wollack, E. J.

    2014-01-01

    We present measurements of the properties of thin film superconducting Mo, Mo2N and Mo2N/Mo/Mo2N trilayers of interest for microwave kinetic inductance detector (MKID) applications. Using microwave resonator devices, we investigate the transition temperature, energy gaps, kinetic inductance, and internal quality factors of these materials. We present an Usadel-based interpretation of the trilayer transition temperature as a function of trilayer thicknesses, and a 2-gap interpretation to understand the change in kinetic inductance and internal resonance quality factor (Q) as a function of temperature.

  6. Encapsulated high frequency (235 kHz), high-Q (100 k) disk resonator gyroscope with electrostatic parametric pump

    NASA Astrophysics Data System (ADS)

    Ahn, C. H.; Nitzan, S.; Ng, E. J.; Hong, V. A.; Yang, Y.; Kimbrell, T.; Horsley, D. A.; Kenny, T. W.

    2014-12-01

    In this paper, we explore the effects of electrostatic parametric amplification on a high quality factor (Q > 100 000) encapsulated disk resonator gyroscope (DRG), fabricated in <100> silicon. The DRG was operated in the n = 2 degenerate wineglass mode at 235 kHz, and electrostatically tuned so that the frequency split between the two degenerate modes was less than 100 mHz. A parametric pump at twice the resonant frequency is applied to the sense axis of the DRG, resulting in a maximum scale factor of 156.6 μV/(°/s), an 8.8× improvement over the non-amplified performance. When operated with a parametric gain of 5.4, a minimum angle random walk of 0.034°/√h and bias instability of 1.15°/h are achieved, representing an improvement by a factor of 4.3× and 1.5×, respectively.

  7. Narrowband thermal radiation from closed-end microcavities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kohiyama, Asaka; Shimizu, Makoto; Iguchi, Fumitada

    2015-10-07

    High spectral selectivity of thermal radiation is important for achieving high-efficiency energy systems. In this study, intense, narrowband, and low directional absorption/radiation were observed in closed-end microcavity which is a conventional open-end microcavity covered by a semi-transparent thin metal film. The quality factor (Q factor) of optical absorption band strongly depended on the film electrical conductivity. Asymmetric and narrow absorption band with a Q factor of 25 at 1.28 μm was obtained for a 6-nm-thick Au film. Numerical simulations suggest that the formation of a fixed-end mode at the cavity aperture contributes to the narrowband optical absorption. The closed-end microcavity filledmore » with SiO{sub 2} exhibits intense and isotropic thermal radiation over a wide solid angle according to numerical simulation. The narrow and asymmetric absorption spectrum was experimentally confirmed in a model of closed-end microcavity.« less

  8. Raman lasing in As₂S₃ high-Q whispering gallery mode resonators.

    PubMed

    Vanier, Francis; Rochette, Martin; Godbout, Nicolas; Peter, Yves-Alain

    2013-12-01

    We report the first observation of a nonlinear process in a chalcogenide microresonator. Raman scattering and stimulated Raman scattering leading to laser oscillation is observed in microspheres made of As₂S₃. The coupled pump power threshold is as low as 13 μW using a pump wavelength of 1550 nm. The quality factor of the chalcogenide microresonator is also the highest ever reported with Q>7×10(7).

  9. A MEMS disk resonator-based band pass filter electrical equivalent circuit simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sundaram, G. M.; Angira, Mahesh; Gupta, Navneet

    In this paper, coupled beam bandpass Disk filter is designed for 1 MHz bandwidth. Filter electrical equivalent circuit simulation is performed using circuit simulators. Important filter parameters such as insertion loss, shape factor and Q factor aresetimated using coventorware simulation. Disk resonator based radial contour mode filter provides 1.5 MHz bandwidth and unloaded quality factor of resonator and filter as 233480, 21797 respectively. From the simulation result it’s found that insertion loss minimum is 151.49 dB, insertion loss maximum is 213.94 dB, and 40 dB shape factor is 4.17.

  10. Relationship between daily isoflavone intake and sleep in Japanese adults: a cross-sectional study.

    PubMed

    Cui, Yufei; Niu, Kaijun; Huang, Cong; Momma, Haruki; Guan, Lei; Kobayashi, Yoritoshi; Guo, Hui; Chujo, Masahiko; Otomo, Atsushi; Nagatomi, Ryoichi

    2015-12-29

    Isoflavones comprise a class of phytoestrogens that resemble human estrogen in chemical structure, and have weak estrogenic effects. Because estrogen modulates sleep duration and quality, we hypothesized that isoflavones would have a beneficial effect on sleep status in a way similar to estrogen. We conducted a cross-sectional study to investigate the relationship between daily isoflavone intake and sleep status in Japanese subjects. Our study included 1076 Japanese adults aged 20-78 years. Daily isoflavone intake was assessed using a brief self-administered diet history questionnaire, and sleep was evaluated using a self-reported questionnaire. The prevalence of regular sleep duration (7-8 h/day) and sufficient sleep quality were 13.3% and 56.2%, respectively. After adjusting for potential confounding factors, the odds ratios (95% CIs) for optimal sleep duration (7-8 h) when higher isoflavone intakes (Q2-Q4) were compared with low isoflavone intake (Q1) were Q2: 0.94 (0.53-1.56); Q3: 1.28 (0.73-2.24); and Q4: 1.84 (1.06-3.18) (p for trend = 0.013). In the final adjusted model, sufficient sleep quality across categories of isoflavone intake was Q1: 1.00 (reference); Q2: 1.30 (0.91-1.84); Q3: 1.48 (1.03-2.12); and Q4: 1.78 (1.22-2.60); (p for trend = 0.002). Higher daily isoflavone intake was positively associated with optimal sleep duration and quality in a Japanese population. This finding suggests that daily isoflavone intake may have a potentially beneficial effect on sleep status.

  11. Sci-Thur PM: YIS - 07: Monte Carlo simulations to obtain several parameters required for electron beam dosimetry.

    PubMed

    Muir, B; Rogers, D; McEwen, M

    2012-07-01

    When current dosimetry protocols were written, electron beam data were limited and had uncertainties that were unacceptable for reference dosimetry. Protocols for high-energy reference dosimetry are currently being updated leading to considerable interest in accurate electron beam data. To this end, Monte Carlo simulations using the EGSnrc user-code egs_chamber are performed to extract relevant data for reference beam dosimetry. Calculations of the absorbed dose to water and the absorbed dose to the gas in realistic ion chamber models are performed as a function of depth in water for cobalt-60 and high-energy electron beams between 4 and 22 MeV. These calculations are used to extract several of the parameters required for electron beam dosimetry - the beam quality specifier, R 50 , beam quality conversion factors, k Q and k R50 , the electron quality conversion factor, k' R50 , the photon-electron conversion factor, k ecal , and ion chamber perturbation factors, P Q . The method used has the advantage that many important parameters can be extracted as a function of depth instead of determination at only the reference depth as has typically been done. Results obtained here are in good agreement with measured and other calculated results. The photon-electron conversion factors obtained for a Farmer-type NE2571 and plane-parallel PTW Roos, IBA NACP-02 and Exradin A11 chambers are 0.903, 0.896, 0.894 and 0.906, respectively. These typically differ by less than 0.7% from the contentious TG-51 values but have much smaller systematic uncertainties. These results are valuable for reference dosimetry of high-energy electron beams. © 2012 American Association of Physicists in Medicine.

  12. The central electrode correction factor for high-Z electrodes in small ionization chambers.

    PubMed

    Muir, B R; Rogers, D W O

    2011-02-01

    Recent Monte Carlo calculations of beam quality conversion factors for ion chambers that use high-Z electrodes [B. R. Muir and D. W. O. Rogers, Med. Phys. 37, 5939-5950 (2010)] have shown large deviations of kQ values from values calculated using the same techniques as the TG-51 and TRS-398 protocols. This report investigates the central electrode correction factor, Pcel, for these chambers. Ionization chambers are modeled and Pcel is calculated using the EGSnrc user code egs_chamber for three cases: in photon and electron beams under reference conditions; as a function of distance from an iridium-192 point source in a water phantom; and as a function of depth in a water phantom on which a 200 kVp x-ray source or 6 MV beam is incident. In photon beams, differences of up to 3% between Pcel calculations for a chamber with a high-Z electrode and those used by TG-51 for a 1 mm diameter aluminum electrode are observed. The central electrode correction factor for a given value of the beam quality specifier is different depending on the amount of filtration of the photon beam. However, in an unfiltered 6 MV beam, Pcel, varies by only 0.3% for a chamber with a high-Z electrode as the depth is varied from 1 to 20 cm in water. The difference between Pcel calculations for chambers with high-Z electrodes and TG-51 values for a chamber with an aluminum electrode is up to 0.45% in electron beams. The central electrode correction, which is roughly proportional to the chambers absorbed dose sensitivity, is found to be large and variable as a function of distance for chambers with high-Z and aluminum electrodes in low-energy photon fields. In this work, ionization chambers that employ high-Z electrodes have been shown to be problematic in various situations. For beam quality conversion factors, the ratio of Pcel in a beam quality Q to that in a Co-60 beam is required; for some chambers, kQ is significantly different from current dosimetry protocol values because of central electrode effects. It would be best for manufacturers to avoid producing ion chambers that use high-Z electrodes.

  13. RF-MEMS Load Sensors with Enhanced Q-factor and Sensitivity in a Suspended Architecture.

    PubMed

    Melik, Rohat; Unal, Emre; Perkgoz, Nihan Kosku; Puttlitz, Christian; Demir, Hilmi Volkan

    2011-03-01

    In this paper, we present and demonstrate RF-MEMS load sensors designed and fabricated in a suspended architecture that increases their quality-factor (Q-factor), accompanied with an increased resonance frequency shift under load. The suspended architecture is obtained by removing silicon under the sensor. We compare two sensors that consist of 195 μm × 195 μm resonators, where all of the resonator features are of equal dimensions, but one's substrate is partially removed (suspended architecture) and the other's is not (planar architecture). The single suspended device has a resonance of 15.18 GHz with 102.06 Q-factor whereas the single planar device has the resonance at 15.01 GHz and an associated Q-factor of 93.81. For the single planar device, we measured a resonance frequency shift of 430 MHz with 3920 N of applied load, while we achieved a 780 MHz frequency shift in the single suspended device. In the planar triplet configuration (with three devices placed side by side on the same chip, with the two outmost ones serving as the receiver and the transmitter), we observed a 220 MHz frequency shift with 3920 N of applied load while we obtained a 340 MHz frequency shift in the suspended triplet device with 3920 N load applied. Thus, the single planar device exhibited a sensitivity level of 0.1097 MHz/N while the single suspended device led to an improved sensitivity of 0.1990 MHz/N. Similarly, with the planar triplet device having a sensitivity of 0.0561 MHz/N, the suspended triplet device yielded an enhanced sensitivity of 0.0867 MHz/N.

  14. Apex-angle-dependent resonances in triangular split-ring resonators

    NASA Astrophysics Data System (ADS)

    Burnett, Max A.; Fiddy, Michael A.

    2016-02-01

    Along with other frequency selective structures (Pendry et al. in IEEE Trans Microw Theory Tech 47(11):2075-2084, 1999) (circles and squares), triangular split-ring resonators (TSRRs) only allow frequencies near the center resonant frequency to propagate. Further, TSRRs are attractive due to their small surface area (Vidhyalakshmi et al. in Stopband characteristics of complementary triangular split ring resonator loaded microstrip line, 2011), comparatively, and large quality factors ( Q) as previously investigated by Gay-Balmaz et al. (J Appl Phys 92(5):2929-2936, 2002). In this work, we examine the effects of varying the apex angle on the resonant frequency, the Q factor, and the phase shift imparted by the TSRR element within the GHz frequency regime.

  15. Enhanced Raman scattering of single nanoparticles in a high-Q whispering-gallery microresonator

    NASA Astrophysics Data System (ADS)

    Liu, Rui-Shan; Jin, Wei-Liang; Yu, Xiao-Chong; Liu, Yong-Chun; Xiao, Yun-Feng

    2015-04-01

    We study Raman scattering of single nanoparticles coupled to a high-Q whispering-gallery microresonator. It is found that cavity resonances greatly enhance the Raman signal, and the enhancement factor is as high as 108. Unlike the noncavity case, the signal power exhibits a nonmonotonic dependence on particle size, and it reaches the maximum when the Rayleigh scattering loss and the cavity intrinsic loss are comparable. We further analyze how the Raman signal intensity is influenced by different parameters including cavity quality factors and taper-cavity coupling strength. The detection limit of observing single-nanoparticle Raman signal is discussed finally. As a potential application, this mechanism may provide an alternative way to detect specific biological targets without the need of precovered biorecognitions.

  16. Development and psychometric properties of a measure of catheter burden with bladder drainage after pelvic reconstructive surgery.

    PubMed

    Carpenter, Janet S; Heit, Michael; Rand, Kevin L

    2017-04-01

    Catheter burden after pelvic reconstructive surgery is an important patient-reported quality of life outcome in research and clinical practice. However, existing tools focus on long-term catheter users rather than short-term postoperative patients. The study aim was to evaluate the psychometric properties of a modified version of the intermittent self-catheterization questionnaire (ISC-Q) in postoperative pelvic reconstructive patients. After experts convened to discuss and modify the ISC-Q items based on their knowledge of women's experiences and clinical practices, 178 women (108 with transurethral and 70 with suprapubic catheters) completed the modified scale and other measures as part of a larger parent study designed to assess health-related quality of life (HRQoL) following pelvic reconstructive surgery requiring bladder drainage. During psychometric testing, the modified ISC-Q was reduced to six items encompassing two factors: a three-item difficulty of use factor and a 3-item embarrassment factor. The new scale was named the short-term catheter burden questionnaire (STCBQ). The two-factor model was robust in both subsamples. Only scores within and not between subsamples can be meaningfully compared due to a lack of scalar invariance. Correlations among STCBQ total scores, subscores, and a single satisfaction item indicated good construct validity. Correlations with patient demographics provided further information about the scale. The STCBQ is a short, efficient assessment of short-term catheter burden following pelvic reconstructive surgery. The scale can be used as an important patient reported outcome measure in clinical practice and research. Neurourol. Urodynam. 36:1140-1146, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  17. Molybdenum-rhenium alloy based high-Q superconducting microwave resonators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, Vibhor, E-mail: v.singh@tudelft.nl; Schneider, Ben H.; Bosman, Sal J.

    2014-12-01

    Superconducting microwave resonators (SMRs) with high quality factors have become an important technology in a wide range of applications. Molybdenum-Rhenium (MoRe) is a disordered superconducting alloy with a noble surface chemistry and a relatively high transition temperature. These properties make it attractive for SMR applications, but characterization of MoRe SMR has not yet been reported. Here, we present the fabrication and characterization of SMR fabricated with a MoRe 60–40 alloy. At low drive powers, we observe internal quality-factors as high as 700 000. Temperature and power dependence of the internal quality-factors suggest the presence of the two level systems from themore » dielectric substrate dominating the internal loss at low temperatures. We further test the compatibility of these resonators with high temperature processes, such as for carbon nanotube chemical vapor deposition growth, and their performance in the magnetic field, an important characterization for hybrid systems.« less

  18. Monolithic Cylindrical Fused Silica Resonators with High Q Factors

    PubMed Central

    Pan, Yao; Wang, Dongya; Wang, Yanyan; Liu, Jianping; Wu, Suyong; Qu, Tianliang; Yang, Kaiyong; Luo, Hui

    2016-01-01

    The cylindrical resonator gyroscope (CRG) is a typical Coriolis vibratory gyroscope whose performance is determined by the Q factor and frequency mismatch of the cylindrical resonator. Enhancing the Q factor is crucial for improving the rate sensitivity and noise performance of the CRG. In this paper, for the first time, a monolithic cylindrical fused silica resonator with a Q factor approaching 8 × 105 (ring-down time over 1 min) is reported. The resonator is made of fused silica with low internal friction and high isotropy, with a diameter of 25 mm and a center frequency of 3974.35 Hz. The structure of the resonator is first briefly introduced, and then the experimental non-contact characterization method is presented. In addition, the post-fabrication experimental procedure of Q factor improvement, including chemical and thermal treatment, is demonstrated. The Q factor improvement by both treatments is compared and the primary loss mechanism is analyzed. To the best of our knowledge, the work presented in this paper represents the highest reported Q factor for a cylindrical resonator. The proposed monolithic cylindrical fused silica resonator may enable high performance inertial sensing with standard manufacturing process and simple post-fabrication treatment. PMID:27483263

  19. Electrical investigations of hybrid OLED microcavity structures with novel encapsulation methods

    NASA Astrophysics Data System (ADS)

    Meister, Stefan; Brückner, Robert; Fröb, Hartmut; Leo, Karl

    2016-04-01

    An electrical driven organic solid state laser is a very challenging goal which is so far well beyond reach. As a step towards realization, we monolithically implemented an Organic Light Emitting Diode (OLED) into a dielectric, high quality microcavity (MC) consisting of two Distributed Bragg Reectors (DBR). In order to account for an optimal optical operation, the OLED structure has to be adapted. Furthermore, we aim to excite the device not only electrically but optically as well. Different OLED structures with an emission layer consisting of Alq3:DCM (2 wt%) were investigated. The External Quantum Efficiencies (EQE) of this hybrid structures are in the range of 1-2 %, as expected for this material combination. Including metal layers into a MC is complicated and has a huge impact on the device performance. Using Transfer-Matrix-Algorithm (TMA) simulations, the best positions for the metal electrodes are determined. First, the electroluminescence (EL) of the adjusted OLED structure on top of a DBR is measured under nitrogen atmosphere. The modes showed quality factors of Q = 60. After the deposition of the top DBR, the EL is measured again and the quality factors increased up to Q = 600. Considering the two 25-nm-thick-silver contacts a Q-factor of 600 is very high. The realization of a suitable encapsulation method is important. Two approaches were successfully tested. The first method is based on the substitution of a DBR layer with a layer produced via Atomic Layer Deposition (ALD). The second method uses a 0.15-mm-thick cover glass glued on top of the DBR with a 0.23-μm-thick single-component glue layer. Due to the working encapsulation, it is possible to investigate the sample under ambient conditions.

  20. Implementing a web-based oncology protocol system in Australia: evaluation of the first 3 years of operation.

    PubMed

    Hains, I M; Ward, R L; Pearson, S-A

    2012-01-01

    EviQ is a web-based oncology protocol system launched across Australia in 2005 (http://www.eviq.org.au). We evaluated eviQ use at the point-of-care and determined the factors impacting on its uptake and routine use in the first three years of operation. We conducted a suite of qualitative and quantitative studies with over 200 Australian oncology physicians, nurses and pharmacists working at treatment centres in diverse geographical locations. EviQ was part of routine care at many hospitals; however, the way in which it was used at the point-of-care varies according to clinician roles and hospital location. We identified a range of factors impacting on eviQ uptake and routine use. Infrastructure, such as availability of point-of-care computers, and formal policies endorsing eviQ are fundamental to increasing uptake. Furthermore, the level of clinical and computer experience of end-users, the attitudes and behaviour of clinicians, endorsement and promotion strategies, and level and type of eviQ education all need to be considered and managed to ensure that the system is being used to its full potential. Our findings show that the dissemination of web-based treatment protocols does not guarantee widespread use. Organisational, environmental and clinician-specific factors play a role in uptake and utilisation. The deployment of sufficient computer infrastructure, implementation of targeted training programmes and hospital policies and investment in marketing approaches are fundamental to uptake and continued use. This study highlights the value of ongoing monitoring and evaluation to ensure systems like eviQ achieve their primary purpose - reducing treatment variation and improving quality of care. © 2010 The Authors. Internal Medicine Journal © 2010 Royal Australasian College of Physicians.

  1. Dynamic increase and decrease of photonic crystal nanocavity Q factors for optical pulse control.

    PubMed

    Upham, Jeremy; Tanaka, Yoshinori; Asano, Takashi; Noda, Susumu

    2008-12-22

    We introduce recent advances in dynamic control over the Q factor of a photonic crystal nanocavity system. By carefully timing a rapid increase of the Q factor from 3800 to 22,000, we succeed in capturing a 4ps signal pulse within the nanocavity with a photon lifetime of 18ps. By performing an additional transition of the Q factor within the photon lifetime, the held light is once again ejected from of the system on demand.

  2. A brachytherapy photon radiation quality index Q(BT) for probe-type dosimetry.

    PubMed

    Quast, Ulrich; Kaulich, Theodor W; Álvarez-Romero, José T; Carlsson Tedgren, Sa; Enger, Shirin A; Medich, David C; Mourtada, Firas; Perez-Calatayud, Jose; Rivard, Mark J; Zakaria, G Abu

    2016-06-01

    In photon brachytherapy (BT), experimental dosimetry is needed to verify treatment plans if planning algorithms neglect varying attenuation, absorption or scattering conditions. The detector's response is energy dependent, including the detector material to water dose ratio and the intrinsic mechanisms. The local mean photon energy E¯(r) must be known or another equivalent energy quality parameter used. We propose the brachytherapy photon radiation quality indexQ(BT)(E¯), to characterize the photon radiation quality in view of measurements of distributions of the absorbed dose to water, Dw, around BT sources. While the external photon beam radiotherapy (EBRT) radiation quality index Q(EBRT)(E¯)=TPR10(20)(E¯) is not applicable to BT, the authors have applied a novel energy dependent parameter, called brachytherapy photon radiation quality index, defined as Q(BT)(E¯)=Dprim(r=2cm,θ0=90°)/Dprim(r0=1cm,θ0=90°), utilizing precise primary absorbed dose data, Dprim, from source reference databases, without additional MC-calculations. For BT photon sources used clinically, Q(BT)(E¯) enables to determine the effective mean linear attenuation coefficient μ¯(E) and thus the effective energy of the primary photons Eprim(eff)(r0,θ0) at the TG-43 reference position Pref(r0=1cm,θ0=90°), being close to the mean total photon energy E¯tot(r0,θ0). If one has calibrated detectors, published E¯tot(r) and the BT radiation quality correction factor [Formula: see text] for different BT radiation qualities Q and Q0, the detector's response can be determined and Dw(r,θ) measured in the vicinity of BT photon sources. This novel brachytherapy photon radiation quality indexQ(BT) characterizes sufficiently accurate and precise the primary photon's penetration probability and scattering potential. Copyright © 2016. Published by Elsevier Ltd.

  3. Electromagnetically induced transparency in planar metamaterials based on guided mode resonance

    NASA Astrophysics Data System (ADS)

    Sun, Yaru; Chen, Hang; Li, Xiangjun; Hong, Zhi

    2017-06-01

    We present and numerically demonstrate a novel, electromagnetically induced transparency (EIT) in planar metamaterials (MMs) based on guided mode resonance (GMR). The unit cell of the MM consists of two metallic ring resonators. The GMR with high quality factor (Q) is achieved by changing the distance between the two rings of the MM. Narrow EIT-like spectral response is realized by coupling between a high Q GMR and a low Q dipolar resonance of the MM. Our work could provide another efficient way towards the realization of EIT with large group index using very simple structures.

  4. Psychometric Evaluation of the Eating Disorder Examination-Questionnaire for Bariatric Surgery Candidates

    PubMed Central

    Hrabosky, Joshua I.; White, Marney A.; Masheb, Robin M.; Rothschild, Bruce S.; Burke-Martindale, Carolyn H.; Grilo, Carlos M.

    2013-01-01

    Objective Despite increasing use of the Eating Disorder Examination-Questionnaire (EDE-Q) in bariatric surgery patients, little is known about the utility and psychometric performance of this self-report measure in this clinical group. The primary purpose of the current study was to evaluate the factor structure and construct validity of the EDE-Q in a large series of bariatric surgery candidates. Methods and Procedures Participants were 337 obese bariatric surgery candidates. Participants completed the EDE-Q and a battery of behavioral and psychological measures. Results Exploratory factor analysis (EFA) and confirmatory factor analysis (CFA) produced a 12-item, 4-factor structure of the EDE-Q. The four factors, interpreted as Dietary Restraint, Eating Disturbance, Appearance Concerns, and Shape/Weight Overvaluation, were found to be internally consistent and converged with other relevant measures of psychopathology. Discussion Factor analysis of the EDE-Q in bariatric surgery candidates did not replicate the original subscales but revealed an alternative factor structure. Future research must further evaluate the psychometric properties, including the factor structure, of the EDE-Q in this and other diverse populations and consider means of improving this measure's ability to best assess eating-related pathology in bariatric surgery patients. PMID:18379561

  5. The best interest of the child-questionnaire, reliability and validity: preliminary data on the question 'where to live after detention or secure treatment?'.

    PubMed

    Kalverboer, Margrite; Ten Brummelaar, Mijntje; Post, Wendy; Zijlstra, Elianne; Harder, Annemiek; Knorth, Erik

    2012-02-01

    The Best Interest of the Child-Questionnaire (BIC-Q) has been designed as an instrument for screening the quality of the rearing situation of children with behavioural problems or delinquency. It is intended to aid legal decisions in juvenile and family law. The aim of the study was to establish the reliability and validation of the BIC-Q. Records of 83 children in detention or secure treatment centres and 58 children with no delinquent behaviours were rated by trained researchers. Interrater reliability was tested with a sub-sample of 31 of the former. Content validity was evaluated across the whole group, using Cronbach's alpha to check internal consistency, Spearman's rho to examine correlations and explorative principal component analysis (PCA) to test the extent to which variance in the 14 underlying conditions could be accounted for by a single factor 'quality of rearing'. Interrater reliability was good (r = 0.89). The PCA lent support to the content validity of the questionnaire with four factors, which together explained 66% of the variance in child rearing: (1) attachment and bonding; (2) rules and provisions; (3) health care and physical care in the family context; and (4) care and models provided for in the societal environment. The BIC-Q is a reliable and valid measure of the overall quality of child rearing. Preliminary results indicate that the BIC-Q may be applied to support court decisions on where the child should live after detention or secure treatment. Copyright © 2011 John Wiley & Sons, Ltd.

  6. Enhanced quality factors and force sensitivity by attaching magnetic beads to cantilevers for atomic force microscopy in liquid

    NASA Astrophysics Data System (ADS)

    Hoof, Sebastian; Nand Gosvami, Nitya; Hoogenboom, Bart W.

    2012-12-01

    Dynamic-mode atomic force microscopy (AFM) in liquid remains complicated due to the strong viscous damping of the cantilever resonance. Here, we show that a high-quality resonance (Q >20) can be achieved in aqueous solution by attaching a microgram-bead at the end of the nanogram-cantilever. The resulting increase in cantilever mass causes the resonance frequency to drop significantly. However, the force sensitivity—as expressed via the minimum detectable force gradient—is hardly affected, because of the enhanced quality factor. Through the enhancement of the quality factor, the attached bead also reduces the relative importance of noise in the deflection detector. It can thus yield an improved signal-to-noise ratio when this detector noise is significant. We describe and analyze these effects for a set-up that includes magnetic actuation of the cantilevers and that can be easily implemented in any AFM system that is compatible with an inverted optical microscope.

  7. Electromagnetically induced transparency with hybrid silicon-plasmonic traveling-wave resonators

    NASA Astrophysics Data System (ADS)

    Ketzaki, Dimitra A.; Tsilipakos, Odysseas; Yioultsis, Traianos V.; Kriezis, Emmanouil E.

    2013-09-01

    Spectral filtering and electromagnetically induced transparency (EIT) with hybrid silicon-plasmonic traveling-wave resonators are theoretically investigated. The rigorous three-dimensional vector finite element method simulations are complemented with temporal coupled mode theory. We show that ring and disk resonators with sub-micron radii can efficiently filter the lightwave with minimal insertion loss and high quality factors (Q). It is shown that disk resonators feature reduced radiation losses and are thus advantageous. They exhibit unloaded quality factors as high as 1000 in the telecom spectral range, resulting in all-pass filtering components with sharp resonances. By cascading two slightly detuned resonators and providing an additional route for resonator interaction (i.e., a second bus waveguide), a response reminiscent of EIT is observed. The EIT transmission peak can be shaped by means of resonator detuning and interelement separation. Importantly, the respective Q can become higher than that of the single-resonator structure. Thus, the possibility of exploiting this peak in switching applications relying on the thermo-optic effect is, finally, assessed.

  8. Characterization of noncontact piezoelectric transducer with conically shaped piezoelement

    NASA Technical Reports Server (NTRS)

    Williams, James H., Jr.; Ochi, Simeon C. U.

    1988-01-01

    The characterization of a dynamic surface displacement transducer (IQI Model 501) by a noncontact method is presented. The transducer is designed for ultrasonic as well as acoustic emission measurements and, according to the manufacturer, its characteristic features include a flat frequency response range which is from 50 to 1000 kHz and a quality factor Q of less than unity. The characterization is based on the behavior of the transducer as a receiver and involves exciting the transducer directly by transient pulse input stress signals of quasi-electrostatic origin and observing its response in a digital storage oscilloscope. Theoretical models for studying the response of the transducer to pulse input stress signals and for generating pulse stress signals are presented. The characteristic features of the transducer which include the central frequency f sub o, quality factor Q, and flat frequency response range are obtained by this noncontact characterization technique and they compare favorably with those obtained by a tone burst method which are also presented.

  9. Effect of surface roughness on liquid property measurements using mechanically oscillating sensors

    NASA Technical Reports Server (NTRS)

    Jain, Mahaveer K.; Grimes, Craig A.

    2002-01-01

    The resonant frequency and quality factor Q of a liquid immersed magnetoelastic sensor are shown to shift linearly with the liquid viscosity and density product. Measurements using different grade oils, organic chemicals, and glycerol-water mixtures show that the surface roughness of the sensor in combination with the molecular size of the liquid play important roles in determining measurement sensitivity, which can be controlled through adjusting the surface roughness of the sensor surface. A theoretical model describing the sensor resonant frequency and quality factor Q as a function of liquid properties is developed using a novel equivalent circuit approach. Experimental results are in agreement with theory when the liquid molecule size is larger than the average surface roughness. However, when the molecular size of the liquid is small relative to the surface roughness features molecules are trapped, and the trapped molecules act both as a mass load and viscous load; the result is higher viscous damping of the sensor than expected. c2002 Elsevier Science B.V. All rights reserved.

  10. SU-E-T-146: Reference Dosimetry for Protons and Light-Ion Beams Based on Graphite Calorimetry.

    PubMed

    Rossomme, S; Palmans, H; Thomas, R; Lee, N; Bailey, M; Shipley, D; Al-Sulaiti, L; Cirrone, P; Romano, F; Kacperek, A; Bertrand, D; Vynckier, S

    2012-06-01

    The IAEA TRS-398 code of practice can be applied for the measurement of absorbed dose to water under reference conditions with an ionization chamber. For protons, the combined relative standard uncertainty on those measurements is less than 2% while for light-ion beams, it is considerably larger, i.e. 3.2%, mainly due to the higher uncertainty contributions for the water to air stopping power ration and the W air-value on the beam quality correction factors kQ,Q 0 . To decrease this uncertainty, a quantification of kQ,Q 0 is proposed using a primary standard level graphite calorimeter. This work includes numerical and experimental determinations of dose conversion factors to derive dose to water from graphite calorimetry. It also reports on the first experimental data obtained with the graphite calorimeter in proton, alpha and carbon ion beams. Firstly, the dose conversion has been calculated with by Geant4 Monte-Carlo simulations through the determination of the water to graphite stopping power ratio and the fluence correction factor. The latter factor was also derived by comparison of measured ionization curves in graphite and water. Secondly, kQ,Q 0 was obtained by comparison of the dose response of ionization chambers with that of the calorimeter. Stopping power ratios are found to vary by no more than 0.35% up to the Bragg peak, while fluence correction factors are shown to increase slightly above unity close to the Bragg peak. The comparison of the calorimeter with ionization chambers is currently under analysis. For the modulated proton beam, preliminary results on W air confirm the value recommended in TRS-398. Data in both the non-modulated proton and light-ion beams indicate higher values but further investigation of heat loss corrections is needed. The application of graphite calorimetry to proton, alpha and carbon ion beams has been demonstrated successfully. Other experimental campaigns will be held in 2012. This work is supported by the BioWin program of the Wallon Government. © 2012 American Association of Physicists in Medicine.

  11. Monte Carlo calculated correction factors for diodes and ion chambers in small photon fields.

    PubMed

    Czarnecki, D; Zink, K

    2013-04-21

    The application of small photon fields in modern radiotherapy requires the determination of total scatter factors Scp or field factors Ω(f(clin), f(msr))(Q(clin), Q(msr)) with high precision. Both quantities require the knowledge of the field-size-dependent and detector-dependent correction factor k(f(clin), f(msr))(Q(clin), Q(msr)). The aim of this study is the determination of the correction factor k(f(clin), f(msr))(Q(clin), Q(msr)) for different types of detectors in a clinical 6 MV photon beam of a Siemens KD linear accelerator. The EGSnrc Monte Carlo code was used to calculate the dose to water and the dose to different detectors to determine the field factor as well as the mentioned correction factor for different small square field sizes. Besides this, the mean water to air stopping power ratio as well as the ratio of the mean energy absorption coefficients for the relevant materials was calculated for different small field sizes. As the beam source, a Monte Carlo based model of a Siemens KD linear accelerator was used. The results show that in the case of ionization chambers the detector volume has the largest impact on the correction factor k(f(clin), f(msr))(Q(clin), Q(msr)); this perturbation may contribute up to 50% to the correction factor. Field-dependent changes in stopping-power ratios are negligible. The magnitude of k(f(clin), f(msr))(Q(clin), Q(msr)) is of the order of 1.2 at a field size of 1 × 1 cm(2) for the large volume ion chamber PTW31010 and is still in the range of 1.05-1.07 for the PinPoint chambers PTW31014 and PTW31016. For the diode detectors included in this study (PTW60016, PTW 60017), the correction factor deviates no more than 2% from unity in field sizes between 10 × 10 and 1 × 1 cm(2), but below this field size there is a steep decrease of k(f(clin), f(msr))(Q(clin), Q(msr)) below unity, i.e. a strong overestimation of dose. Besides the field size and detector dependence, the results reveal a clear dependence of the correction factor on the accelerator geometry for field sizes below 1 × 1 cm(2), i.e. on the beam spot size of the primary electrons hitting the target. This effect is especially pronounced for the ionization chambers. In conclusion, comparing all detectors, the unshielded diode PTW60017 is highly recommended for small field dosimetry, since its correction factor k(f(clin), f(msr))(Q(clin), Q(msr)) is closest to unity in small fields and mainly independent of the electron beam spot size.

  12. Quantitative polymerase chain reaction (PCR) for detection of aquatic animal pathogens in a diagnostic laboratory setting

    USGS Publications Warehouse

    Purcell, Maureen K.; Getchell, Rodman G.; McClure, Carol A.; Weber, S.E.; Garver, Kyle A.

    2011-01-01

    Real-time, or quantitative, polymerase chain reaction (qPCR) is quickly supplanting other molecular methods for detecting the nucleic acids of human and other animal pathogens owing to the speed and robustness of the technology. As the aquatic animal health community moves toward implementing national diagnostic testing schemes, it will need to evaluate how qPCR technology should be employed. This review outlines the basic principles of qPCR technology, considerations for assay development, standards and controls, assay performance, diagnostic validation, implementation in the diagnostic laboratory, and quality assurance and control measures. These factors are fundamental for ensuring the validity of qPCR assay results obtained in the diagnostic laboratory setting.

  13. Studies on the Electrical Properties of Graphene Oxide-Reinforced Poly (4-Styrene Sulfonic Acid) and Polyvinyl Alcohol Blend Composites

    NASA Astrophysics Data System (ADS)

    Deshmukh, Kalim; Sankaran, Sowmya; Basheer Ahamed, M.; Khadheer Pasha, S. K.; Sadasivuni, Kishor Kumar; Ponnamma, Deepalekshmi; Al-Ali Almaadeed, Mariam; Chidambaram, K.

    In the present study, graphene oxide (GO)-reinforced poly (4-styrenesulfonic acid) (PSSA)/polyvinyl alcohol (PVA) blend composite films were prepared using colloidal blending technique at various concentrations of GO (0-3wt.%). The morphological investigations of the prepared composites were carried out using polarized optical microscopy and scanning electron microscopy. The electrical properties of composites were evaluated using an impedance analyzer in the frequency range 50Hz to 20MHz and temperature in the range 40-150∘C. Morphological studies infer that GO was homogeneously dispersed in the PSSA/PVA blend matrix. Investigations of electrical property indicate that the incorporation of GO into PSSA/PVA blend matrix resulted in the enhancement of the impedance (Z) and the quality factor (Q-factor) values. A maximum impedance of about 4.32×106Ω was observed at 50Hz and 90∘C for PSSA/PVA/GO composites with 3wt.% GO loading. The Q-factor also increased from 8.37 for PSSA/PVA blend to 59.8 for PSSA/PVA/GO composites with 3wt.% GO loading. These results indicate that PSSA/PVA/GO composites can be used for high-Q capacitor applications.

  14. Using BMDP and SPSS for a Q factor analysis.

    PubMed

    Tanner, B A; Koning, S M

    1980-12-01

    While Euclidean distances and Q factor analysis may sometimes be preferred to correlation coefficients and cluster analysis for developing a typology, commercially available software does not always facilitate their use. Commands are provided for using BMDP and SPSS in a Q factor analysis with Euclidean distances.

  15. Measurement of the dynamic input impedance of a dc superconducting quantum interference device at audio frequencies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Falferi, P.; Mezzena, R.; Vitale, S.

    1997-08-01

    The coupling effects of a commercial dc superconducting quantum interference device (SQUID) to an electrical LC resonator which operates at audio frequencies ({approx}1kHz) with quality factors Q{approx}10{sup 6} are presented. The variations of the resonance frequency of the resonator as functions of the flux applied to the SQUID are due to the SQUID dynamic inductance in good agreement with the predictions of a model. The variations of the quality factor point to a feedback mechanism between the output of the SQUID and the input circuit. {copyright} {ital 1997 American Institute of Physics.}

  16. Silicon nano-membrane based photonic crystal microcavities for high sensitivity bio-sensing.

    PubMed

    Lai, Wei-Cheng; Chakravarty, Swapnajit; Zou, Yi; Chen, Ray T

    2012-04-01

    We experimentally demonstrated photonic crystal microcavity based resonant sensors coupled to photonic crystal waveguides in silicon nano-membrane on insulator for chemical and bio-sensing. Linear L-type microcavities are considered. In contrast to cavities with small mode volumes, but low quality factors for bio-sensing, we showed increasing the length of the microcavity enhances the quality factor of the resonance by an order of magnitude and increases the resonance wavelength shift while retaining compact device characteristics. Q~26760 and sensitivity down to 15 ng/ml and ~110 pg/mm2 in bio-sensing was experimentally demonstrated on silicon-on-insulator devices.

  17. Frequency-constant Q, unity and disorder

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hargreaves, N.D.

    1995-12-31

    In exploration geophysics we obtain information about the earth by observing its response to different types of applied force. The response can cover the full range of possible Q values (where Q, the quality factor, is a measure of energy dissipation), from close to infinity in the case of deep crustal seismic to close to 0 in the case of many electromagnetic methods. When Q is frequency-constant, however, the various types of response have a common scaling behavior and can be described as being self-affine. The wave-equation then takes on a generalised form, changing from the standard wave-equation at Qmore » = {infinity} to the diffusion equation at Q = 0, via lossy, diffusive, propagation at intermediate Q values. Solutions of this wave-diffusion equation at any particular Q value can be converted to an equivalent set of results for any other Q value. In particular it is possible to convert from diffusive to wave propagation by a mapping from Q < {infinity} to Q = {infinity}. In the context of seismic sounding this is equivalent to applying inverse Q-filtering; in a more general context the mapping integrates different geophysical observations by referencing them to the common result at Q = {infinity}. The self-affinity of the observations for frequency-constant Q is an expression of scale invariance in the fundamental physical properties of the medium of propagation, this being the case whether the mechanism of diffusive propagation is scattering of intrinsic attenuation. Scale invariance, or fractal scaling, is a general property of disordered systems; the assumption of frequency-constant Q not only implies a unity between different geophysical observations, but also suggests that it is the disordered nature of the earth`s sub-surface that is the unifying factor.« less

  18. Study of the in-medium nucleon electromagnetic form factors using a light-front nucleon wave function combined with the quark-meson coupling model

    NASA Astrophysics Data System (ADS)

    de Araújo, W. R. B.; de Melo, J. P. B. C.; Tsushima, K.

    2018-02-01

    We study the nucleon electromagnetic (EM) form factors in symmetric nuclear matter as well as in vacuum within a light-front approach using the in-medium inputs calculated by the quark-meson coupling model. The same in-medium quark properties are used as those used for the study of in-medium pion properties. The zero of the proton EM form factor ratio in vacuum, the electric to magnetic form factor ratio μpGEp (Q2) /GMp (Q2) (Q2 = -q2 > 0 with q being the four-momentum transfer), is determined including the latest experimental data by implementing a hard constituent quark component in the nucleon wave function. A reasonable fit is achieved for the ratio μpGEp (Q2) /GMp (Q2) in vacuum, and we predict that the Q02 value to cross the zero of the ratio to be about 15 GeV2. In addition the double ratio data of the proton EM form factors in 4He and H nuclei, [GEp4He (Q2) /G4HeMp (Q2) ] / [GEp1H (Q2) /GMp1H (Q2) ], extracted by the polarized (e → ,e‧ p →) scattering experiment on 4He at JLab, are well described. We also predict that the Q02 value satisfying μpGEp (Q02) /GMp (Q0 2) = 0 in symmetric nuclear matter, shifts to a smaller value as increasing nuclear matter density, which reflects the facts that the faster falloff of GEp (Q2) as increasing Q2 and the increase of the proton mean-square charge radius. Furthermore, we calculate the neutron EM form factor double ratio in symmetric nuclear matter for 0.1

  19. Quadrupole-Quadrupole Interactions to Control Plasmon-Induced Transparency

    NASA Astrophysics Data System (ADS)

    Rana, Goutam; Deshmukh, Prathmesh; Palkhivala, Shalom; Gupta, Abhishek; Duttagupta, S. P.; Prabhu, S. S.; Achanta, VenuGopal; Agarwal, G. S.

    2018-06-01

    Radiative dipolar resonance with Lorentzian line-shape induces the otherwise dark quadrupolar resonances resulting in electromagnetically induced transparency (EIT). The two interfering excitation pathways of the dipole are earlier shown to result in a Fano line shape with a high figure of merit suitable for sensing. In metamaterials made of metal nanorods or antennas, the plasmonic EIT (PIT) efficiency depends on the overlap of the dark and bright mode spectra as well as the asymmetry resulting from the separation between the monomer (dipole) and dimer (quadrupole) that governs the coupling strength. Increasing asymmetry in these structures leads to the reduction of the figure of merit due to a broadening of the Fano resonance. We demonstrate a PIT system in which the simultaneous excitation of two dipoles result in double PIT. The corresponding two quadrupoles interact and control the quality factor (Q ) of the PIT resonance. We show an antiresonancelike symmetric line shape with nonzero asymmetry factors. The PIT resonance vanishes due to quadrupole-quadrupole coupling. A Q factor of more than 100 at 0.977 THz is observed, which is limited by the experimental resolution of 6 GHz. From polarization-dependent studies we show that the broadening of the Lorentzian resonance is due to scattering-induced excitation of orthogonally oriented dipoles in the monomer and dimer bars in the terahertz regime. The high Q factors in the terahertz frequency region demonstrated here are interesting for sensing application.

  20. Personality in wild bonobos (Pan paniscus).

    PubMed

    Garai, Cintia; Weiss, Alexander; Arnaud, Coline; Furuichi, Takeshi

    2016-11-01

    To understand the evolution of personality structure requires examining personality dimensions in multiple species using a common set of traits. Little research has been conducted on personality in wild populations of nonhuman primates. Using behavioral observations and questionnaire ratings, we examined factors influencing personality in 16 wild bonobos (Pan paniscus) at Wamba, Luo Scientific Reserve, Democratic Republic of the Congo. We extracted five factors from 31 of the items from the Hominoid Personality Questionnaire (HPQ) and three factors from observed behaviors. The HPQ factors were labeled Unemotionality Q , Friendliness Q , Aggressiveness Q , Irritability Q , and Activity Q . The behavioral factors were labeled Grooming B , Playfulness B , and Introversion B . We established the convergent and divergent validity of these factors by obtaining correlations between the HPQ and behavioral factors. We tested for sex differences and found that males were significantly higher on Introversion B and significantly lower in Irritability Q . We then tested for age differences and found that Friendliness Q was lower and Aggressiveness Q was higher in older individuals. Finally, we found that, among males, hierarchical rank was associated with higher Aggressiveness Q . These findings contrast with findings in chimpanzees in ways consistent with known species differences. For one, consistent with the more egalitarian structure of bonobo society, we did not identify a clear Dominance factor. Also, the results related to sex differences were consistent with previous findings that reveal closer bonds between female bonobos than female chimpanzees. These findings highlight the importance of studying personality in closely related species and the need to consider species' socioecology when studying personality. Am. J. Primatol. 78:1178-1189, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  1. Frequency stability of maser oscillators operated with cavity Q. [hydrogen and rubidium masers

    NASA Technical Reports Server (NTRS)

    Tetu, M.; Tremblay, P.; Lesage, P.; Petit, P.; Audoin, C.

    1982-01-01

    The short term frequency stability of masers equipped with an external feedback loop to increase the cavity quality factor was studied. The frequency stability of a hydrogen and a rubidium maser were measured and compared with theoretical evaluation. It is shown that the frequency stability passes through an optimum when the cavity Q is varied. Long term fluctuations are discussed and the optimum mid term frequency stability achievably by small size active and passive H-masers is considered.

  2. Electromagnetic and axial-vector form factors of the quarks and nucleon

    NASA Astrophysics Data System (ADS)

    Dahiya, Harleen; Randhawa, Monika

    2017-11-01

    In light of the improved precision of the experimental measurements and enormous theoretical progress, the nucleon form factors have been evaluated with an aim to understand how the static properties and dynamical behavior of nucleons emerge from the theory of strong interactions between quarks. We have analyzed the vector and axial-vector nucleon form factors (GE,Mp,n(Q2) and GAp,n(Q2)) using the spin observables in the chiral constituent quark model (χCQM) which has made a significant contribution to the unraveling of the internal structure of the nucleon in the nonperturbative regime. We have also presented a comprehensive analysis of the flavor decomposition of the form factors (GEq(Q2), GMq(Q2) and GAq(Q2) for q = u,d,s) within the framework of χCQM with emphasis on the extraction of the strangeness form factors which are fundamental to determine the spin structure and test the chiral symmetry breaking effects in the nucleon. The Q2 dependence of the vector and axial-vector form factors of the nucleon has been studied using the conventional dipole form of parametrization. The results are in agreement with the available experimental data.

  3. Attention in western Nevada: Preliminary results from earthquake and explosion sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hough, S.E.; Anderson, J.G.; Patton, H.J.

    1989-02-01

    We present preliminary results from a study of the attenuation of regional seismic waves at frequencies between 1 and 15 Hz and distances up to 250 km in Western Nevada. Following the methods of Anderson and Hough (1984) and Hough et al. (1988), we parameterize the asymptote of the high frequency acceleration spectrum by the two-parameter model. We relate the model parameters to a two-layer model for Q/sub i/ and Q/sub d/, the freuqency-independent and the frequency dependent components of the quality factor. We compare our results to previously published Q studies in the Basin and Range and find thatmore » our estimate of total Q, Q/sub t/, in the shallow crust is consistent with shear wave Q at close distances with previous estimates of coda Q (Singh and Hermann, 1983) and LgQ (Chavez and Priestley, 1986), suggesting that both coda Q and LgQ are insensitive to near-surface contributions to attenuation.« less

  4. Low-frequency centroid-moment-tensor inversion from superconducting-gravimeter data: The effect of seismic attenuation

    NASA Astrophysics Data System (ADS)

    Zábranová, Eliška; Matyska, Ctirad

    2014-10-01

    After the 2010 Maule and 2011 Tohoku earthquakes the spheroidal modes up to 1 mHz were clearly registered by the Global Geodynamic Project (GGP) network of superconducting gravimeters (SG). Fundamental parameters in synthetic calculations of the signals are the quality factors of the modes. We study the role of their uncertainties in the centroid-moment-tensor (CMT) inversions. First, we have inverted the SG data from selected GGP stations to jointly determine the quality factors of these normal modes and the three low-frequency CMT components, Mrr,(Mϑϑ-Mφφ)/2 and Mϑφ, that generate the observed SG signal. We have used several-days-long records to minimize the trade-off between the quality factors and the CMT but it was not eliminated completely. We have also inverted each record separately to get error estimates of the obtained parameters. Consequently, we have employed the GGP records of 60-h lengths for several published modal-quality-factor sets and inverted only the same three CMT components. The obtained CMT tensors are close to the solution from the joint Q-CMT inversion of longer records and resulting variability of the CMT components is smaller than differences among routine agency solutions. Reliable low-frequency CMT components can thus be obtained for any quality factors from the studied sets.

  5. High-Q photonic resonators and electro-optic coupling using silicon-on-lithium-niobate

    PubMed Central

    Witmer, Jeremy D.; Valery, Joseph A.; Arrangoiz-Arriola, Patricio; Sarabalis, Christopher J.; Hill, Jeff T.; Safavi-Naeini, Amir H.

    2017-01-01

    Future quantum networks, in which superconducting quantum processors are connected via optical links, will require microwave-to-optical photon converters that preserve entanglement. A doubly-resonant electro-optic modulator (EOM) is a promising platform to realize this conversion. Here, we present our progress towards building such a modulator by demonstrating the optically-resonant half of the device. We demonstrate high quality (Q) factor ring, disk and photonic crystal resonators using a hybrid silicon-on-lithium-niobate material system. Optical Q factors up to 730,000 are achieved, corresponding to propagation loss of 0.8 dB/cm. We also use the electro-optic effect to modulate the resonance frequency of a photonic crystal cavity, achieving a electro-optic modulation coefficient between 1 and 2 pm/V. In addition to quantum technology, we expect that our results will be useful both in traditional silicon photonics applications and in high-sensitivity acousto-optic devices. PMID:28406177

  6. Q-Type Factor Analysis of Healthy Aged Men.

    ERIC Educational Resources Information Center

    Kleban, Morton H.

    Q-type factor analysis was used to re-analyze baseline data collected in 1957, on 47 men aged 65-91. Q-type analysis is the use of factor methods to study persons rather than tests. Although 550 variables were originally studied involving psychiatry, medicine, cerebral metabolism and chemistry, personality, audiometry, dichotic and diotic memory,…

  7. Ground-state factorization and correlations with broken symmetry

    NASA Astrophysics Data System (ADS)

    Tomasello, B.; Rossini, D.; Hamma, A.; Amico, L.

    2011-10-01

    We show how the phenomenon of factorization in a quantum many-body system is of collective nature. To this aim we study the quantum discord Q in the one-dimensional XY model in a transverse field. We analyze the behavior of Q at both the critical point and at the non-critical factorizing field. The factorization is found to be governed by an exponential scaling law for Q. We also address the thermal effects fanning out from the anomalies occurring at zero temperature. Close to the quantum phase transition, Q exhibits a finite-temperature crossover with universal scaling behavior, while the factorization phenomenon results in a non-trivial pattern of correlations present at low temperature.

  8. Dispersion and dispersion slope compensation impact on high channel bit rate optical signal transmission degradation

    NASA Astrophysics Data System (ADS)

    Hamidine, Mahamadou; Yuan, Xiuhua

    2011-11-01

    In this article a numerical simulation is carried out on a single channel optical transmission system with channel bit rate greater than 40 Gb/s to investigate optical signal degradation due to the impact of dispersion and dispersion slope of both transmitting and dispersion compensating fibers. By independently varying the input signal power and the dispersion slope of both transmitting and dispersion compensating fibers of an optical link utilizing a channel bit rate of 86 Gb/s, a good quality factor (Q factor) is obtained with a dispersion slope compensation ratio change of +/-10% for a faithful transmission. With this ratio change a minimum Q factor of 16 dB is obtained in the presence of amplifier noise figure of 5 dB and fiber nonlinearities effects at input signal power of 5 dBm and 3 spans of 100 km standard single mode fiber with a dispersion (D) value of 17 ps/nm.km.

  9. Simulation of all-optical logic NOR gate based on two-photon absorption with semiconductor optical amplifier-assisted Mach-Zehnder interferometer with the effect of amplified spontaneous emission

    NASA Astrophysics Data System (ADS)

    Kotb, Amer

    2015-05-01

    The performance of an all-optical NOR gate is numerically simulated and investigated. The NOR Boolean function is realized by using a semiconductor optical amplifier (SOA) incorporated in Mach-Zehnder interferometer (MZI) arms and exploiting the nonlinear effect of two-photon absorption (TPA). If the input pulse intensities is adjusting to be high enough, the TPA-induced phase change can be larger than the regular gain-induced phase change and hence support ultrafast operation in the dual rail switching mode. The numerical study is carried out by taking into account the effect of the amplified spontaneous emission (ASE). The dependence of the output quality factor ( Q-factor) on critical data signals and SOAs parameters is examined and assessed. The obtained results confirm that the NOR gate implemented with the proposed scheme is capable of operating at a data rate of 250 Gb/s with logical correctness and high output Q-factor.

  10. Micropillars with a controlled number of site-controlled quantum dots

    NASA Astrophysics Data System (ADS)

    Kaganskiy, Arsenty; Gericke, Fabian; Heuser, Tobias; Heindel, Tobias; Porte, Xavier; Reitzenstein, Stephan

    2018-02-01

    We report on the realization of micropillars with site-controlled quantum dots (SCQDs) in the active layer. The SCQDs are grown via the buried stressor approach which allows for the positioned growth and device integration of a controllable number of QDs with high optical quality. This concept is very powerful as the number and the position of SCQDs in the cavity can be simultaneously controlled by the design of the buried-stressor. The fabricated micropillars exhibit a high degree of position control for the QDs above the buried stressor and Q-factors of up to 12 000 at an emission wavelength of around 930 nm. We experimentally analyze and numerically model the cavity Q-factor, the mode volume, the Purcell factor, and the photon-extraction efficiency as a function of the aperture diameter of the buried stressor. Exploiting these SCQD micropillars, we experimentally observe a Purcell enhancement in the single-QD regime with FP = 4.3 ± 0.3.

  11. Photon hopping and nanowire based hybrid plasmonic waveguide and ring-resonator

    PubMed Central

    Gu, Zhiyuan; Liu, Shuai; Sun, Shang; Wang, Kaiyang; Lyu, Quan; Xiao, Shumin; Song, Qinghai

    2015-01-01

    Nanowire based hybrid plasmonic structure plays an important role in achieving nanodevices, especially for the wide band-gap materials. However, the conventional schemes of nanowire based devices such as nano-resonators are usually isolated from the integrated nano-network and have extremely low quality (Q) factors. Here we demonstrate the transmission of waves across a gap in hybrid plasmonic waveguide, which is termed as “photon hopping”. Based on the photon hopping, we show that the emissions from nanodevices can be efficiently collected and conducted by additional nanowires. The collection ratio can be higher than 50% for a wide range of separation distance, transverse shift, and tilt. Moreover, we have also explored the possibility of improving performances of individual devices by nano-manipulating the nanowire to a pseudo-ring. Our calculations show that both Q factor and Purcell factor have been increased by more than an order of magnitude. We believe that our researches will be essential to forming nanolasers and the following nano-networks.

  12. Quality of life, self-stigma, and hope in schizophrenia spectrum disorders: a cross-sectional study

    PubMed Central

    Vrbova, Kristyna; Prasko, Jan; Ociskova, Marie; Kamaradova, Dana; Marackova, Marketa; Holubova, Michaela; Grambal, Ales; Slepecky, Milos; Latalova, Klara

    2017-01-01

    Goals The aim of this study was to explore the quality of life, self-stigma, personality traits, and hope in patients with schizophrenia spectrum disorders. Patients and methods A total of 52 outpatients participated in this cross-sectional study. The attending psychiatrist assessed each patient with Mini International Neuropsychiatric Interview (MINI). The patients then completed Quality of Life Satisfaction and Enjoyment Questionnaire (Q-LES-Q), Internalized Stigma of Mental Illness (ISMI) Scale, Temperament and Character Inventory – Revised (TCI-R), Adult Dispositional Hope Scale (ADHS), Drug Attitude Inventory 10 (DAI-10), and Liebowitz Social Anxiety Scale (LSAS)-Self-report. The psychiatrist evaluated Clinical Global Impression Severity – the objective version (objCGI-S), and the patients completed the Clinical Global Impression Severity – the subjective version (subjCGI-S). Each participant also completed Beck Depression Inventory-II (BDI-II), and Beck Anxiety Inventory (BAI). Results The quality of life was significantly higher in employed patients and individuals with higher hope, self-directedness (SD), and persistence (PS). The quality of life was lower among patients with higher number of psychiatric hospitalizations, those with higher severity of the disorder, and individuals who were taking higher doses of antipsychotics. Patients with more pronounced symptoms of depression, anxiety, and social anxiety had a lower quality of life. Finally, the quality of life was lower among individuals with higher harm avoidance (HA) and self-stigmatization (ISMI). Backward stepwise regression was applied to identify the most significant factors connected to self-stigma. The regression analysis showed that occupation, level of depression (BDI-II), attitude to using medication (DAI-10), social anxiety (LSAS), and antipsychotic index were the most relevant factors associated with lower quality of life. Conclusion Detection of the quality of life in the context of personality traits, hope, self-stigma, and demographic and clinical factors may be an important part of the assessment of the patient with schizophrenia. PMID:28260904

  13. Quality of life, self-stigma, and hope in schizophrenia spectrum disorders: a cross-sectional study.

    PubMed

    Vrbova, Kristyna; Prasko, Jan; Ociskova, Marie; Kamaradova, Dana; Marackova, Marketa; Holubova, Michaela; Grambal, Ales; Slepecky, Milos; Latalova, Klara

    2017-01-01

    The aim of this study was to explore the quality of life, self-stigma, personality traits, and hope in patients with schizophrenia spectrum disorders. A total of 52 outpatients participated in this cross-sectional study. The attending psychiatrist assessed each patient with Mini International Neuropsychiatric Interview (MINI). The patients then completed Quality of Life Satisfaction and Enjoyment Questionnaire (Q-LES-Q), Internalized Stigma of Mental Illness (ISMI) Scale, Temperament and Character Inventory - Revised (TCI-R), Adult Dispositional Hope Scale (ADHS), Drug Attitude Inventory 10 (DAI-10), and Liebowitz Social Anxiety Scale (LSAS)-Self-report. The psychiatrist evaluated Clinical Global Impression Severity - the objective version (objCGI-S), and the patients completed the Clinical Global Impression Severity - the subjective version (subjCGI-S). Each participant also completed Beck Depression Inventory-II (BDI-II), and Beck Anxiety Inventory (BAI). The quality of life was significantly higher in employed patients and individuals with higher hope, self-directedness (SD), and persistence (PS). The quality of life was lower among patients with higher number of psychiatric hospitalizations, those with higher severity of the disorder, and individuals who were taking higher doses of antipsychotics. Patients with more pronounced symptoms of depression, anxiety, and social anxiety had a lower quality of life. Finally, the quality of life was lower among individuals with higher harm avoidance (HA) and self-stigmatization (ISMI). Backward stepwise regression was applied to identify the most significant factors connected to self-stigma. The regression analysis showed that occupation, level of depression (BDI-II), attitude to using medication (DAI-10), social anxiety (LSAS), and antipsychotic index were the most relevant factors associated with lower quality of life. Detection of the quality of life in the context of personality traits, hope, self-stigma, and demographic and clinical factors may be an important part of the assessment of the patient with schizophrenia.

  14. Using the Q10 model to simulate E. coli survival in cowpats on grazing lands

    EPA Science Inventory

    Microbiological quality of surface waters can be affected by microbial load in runoff from grazing lands. This effect, with other factors, depends on the survival of microorganisms in animal waste deposited on pastures. Since temperature is a leading environmental parameter affec...

  15. Retrospective Examination of Q Fever Endocarditis: An Underdiagnosed Disease in the Mainland of China

    PubMed Central

    Han, Xiao; Hsu, Jeffrey; Miao, Qi; Zhou, Bao-Tong; Fan, Hong-Wei; Xiong, Xiao-Lu; Wen, Bo-Hai; Wu, Lian; Yan, Xiao-Wei; Fang, Quan; Chen, Wei

    2017-01-01

    Background: Q fever endocarditis, a chronic illness caused by Coxiella burnetii, can be fatal if misdiagnosed or left untreated. Despite a relatively high positive rate of Q fever serology in healthy individuals in the mainland of China, very few cases of Q fever endocarditis have been reported. This study summarized cases of Q fever endocarditis among blood culture negative endocarditis (BCNE) patients and discussed factors attributing to the low diagnostic rate. Methods: We identified confirmed cases of Q fever endocarditis among 637 consecutive patients with infective endocarditis (IE) in the Peking Union Medical College Hospital between 2006 and 2016. The clinical findings for each confirmed case were recorded. BCNE patients were also examined and each BCNE patient's Q fever risk factors were identified. The risk factors and presence of Q fever serologic testing between BCNE patients suspected and unsuspected of Q fever were compared using the Chi-squared or Chi-squared with Yates’ correction for continuity. Results: Among the IE patients examined, there were 147 BCNE patients, of whom only 11 patients (7.5%) were suspected of Q fever and undergone serological testing for C. burnetii. Six out of 11 suspected cases were diagnosed as Q fever endocarditis. For the remaining136 BCNE patients, none of them was suspected of Q fever nor underwent relevant testing. Risk factors for Q fever endocarditis were comparable between suspected and unsuspected patients, with the most common risk factors being valvulopathy in both groups. However, significantly more patients had consulted the Infectious Diseases Division and undergone comprehensive diagnostic tests in the suspected group than the unsuspected group (100% vs. 63%, P = 0.03). Conclusions: Q fever endocarditis is a serious yet treatable condition. Lacking awareness of the disease may prevent BCNE patients from being identified, despite having Q fever risk factors. Increasing awareness and guideline adherence are crucial in avoiding misdiagnosing and missed diagnosing of the disease. PMID:28051025

  16. TH-CD-BRA-03: Direct Measurement of Magnetic Field Correction Factors, KQB, for Application in Future Codes of Practice for Reference Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wolthaus, J; Asselen, B van; Woodings, S

    2016-06-15

    Purpose: With an MR-linac, radiation is delivered in the presence of a magnetic field. Modifications in the codes of practice (CoPs) for reference dosimetry are required to incorporate the effect of the magnetic field. Methods: In most CoPs the absorbed dose is determined using the well-known kQ formalism as the product of the calibration coefficient, the corrected electrometer reading and kQ, to account for the difference in beam quality. To keep a similar formalism a single correction factor is introduced which replaces kQ, and which corrects for beam quality and B-field, kQ,B. In this study we propose a method tomore » determine kQ,B under reference conditions in the MRLinac without using a primary standard, as the product of:- the ratio between detector readings without and with B-field (kB),- the ratio between doses in the point of measurement with and without B-field (rho),- kQ in the absence of the B-field in the MRLinac beam (kQmrl0,Q0),The ratio of the readings, which covers the change in detector reading due to the different electron trajectories in the detector, was measured with a waterproof ionization chamber (IBA-FC65g) in a water phantom in the MRLinac without and with B-field. The change in dose-to-water in the point of measurement due to the B-field was determined with a Monte Carlo based TPS. Results: For the presented approach, the measured ratio of readings is 0.956, the calculated ratio of doses in the point of measurement is 0.995. Based on TPR20,10 measurements kQ was calculated as 0.989 using NCS-18. This yields a value of 0.9408 for kQ,B. Conclusion: The presented approach to determine kQ,B agrees with a method based on primary standards within 0.4% with an uncertainty of 1% (1 std.uncert). It differs from a similar approach using a PMMA-phantom and an NE2571 chamber with 1.3%.« less

  17. Oncology patients' perceptions of "the good nurse": a descriptive study in Flanders, Belgium.

    PubMed

    Van der Elst, Elisa; Dierckx de Casterlé, Bernadette; Biets, Robin; Rchaidia, Leila; Gastmans, Chris

    2013-11-01

    The image of "the good nurse" is mainly studied from the perspective of nurses, which often does not match the image held by patients. Therefore, a descriptive study was conducted to examine oncology patients' perceptions of "the good nurse" and the influence of patient- and context-related variables. A cross-sectional, comparative, descriptive design was used. The sample comprised 557 oncology patients at one of six Flemish hospitals, where they were treated in an oncology day-care unit, oncology hospital ward, or palliative care unit. Data were collected using the Flemish Care-Q instrument. Factor analysis summarised the most important characteristics of "the good nurse". We reassessed the reliability and construct validity of the Flemish Care-Q and examined the influence of patient- and context-related variables on patient perceptions. Using factor analysis, we grouped the different items of the Flemish Care-Q according to three characteristics: "the good nurse" (I) has a supportive and communicative attitude towards patient and family, (II) is competent and employs a professional attitude, and (III) demonstrates personal involvement towards patient and family. Median factor scores of Factors I, II, and III, respectively, were 8.00, 9.00, and 8.00 (varying from 1, not important, to 10, very important). In order of importance, Factors II, I, and III were identified as valuable characteristics of "the good nurse". Gender, care setting, and province were influential variables. As perceived by oncology patients, "the good nurse" has a broad range of qualities, of which competence and professionalism are the most valuable.

  18. Universal behavior of the γ⁎γ→(π0,η,η′) transition form factors

    PubMed Central

    Melikhov, Dmitri; Stech, Berthold

    2012-01-01

    The photon transition form factors of π, η and η′ are discussed in view of recent measurements. It is shown that the exact axial anomaly sum rule allows a precise comparison of all three form factors at high-Q2 independent of the different structures and distribution amplitudes of the participating pseudoscalar mesons. We conclude: (i) The πγ form factor reported by Belle is in excellent agreement with the nonstrange I=0 component of the η and η′ form factors obtained from the BaBar measurements. (ii) Within errors, the πγ form factor from Belle is compatible with the asymptotic pQCD behavior, similar to the η and η′ form factors from BaBar. Still, the best fits to the data sets of πγ, ηγ, and η′γ form factors favor a universal small logarithmic rise Q2FPγ(Q2)∼log(Q2). PMID:23226917

  19. $$B\\to Kl^+l^-$$ decay form factors from three-flavor lattice QCD

    DOE PAGES

    Bailey, Jon A.

    2016-01-27

    We compute the form factors for the B → Kl +l - semileptonic decay process in lattice QCD using gauge-field ensembles with 2+1 flavors of sea quark, generated by the MILC Collaboration. The ensembles span lattice spacings from 0.12 to 0.045 fm and have multiple sea-quark masses to help control the chiral extrapolation. The asqtad improved staggered action is used for the light valence and sea quarks, and the clover action with the Fermilab interpretation is used for the heavy b quark. We present results for the form factors f+(q 2), f 0(q 2), and f T(q 2), where q 2more » is the momentum transfer, together with a comprehensive examination of systematic errors. Lattice QCD determines the form factors for a limited range of q 2, and we use the model-independent z expansion to cover the whole kinematically allowed range. We present our final form-factor results as coefficients of the z expansion and the correlations between them, where the errors on the coefficients include statistical and all systematic uncertainties. Lastly, we use this complete description of the form factors to test QCD predictions of the form factors at high and low q 2.« less

  20. Measurement of the quality factor of a new low-frequency differential accelerometer for testing the equivalence principle.

    PubMed

    Iafolla, V; Lefevre, C; Fiorenza, E; Santoli, F; Nozzoli, S; Magnafico, C; Lucente, M; Lucchesi, D; Peron, R; Shapiro, I I; Glashow, S; Lorenzini, E C

    2014-01-01

    A cryogenic differential accelerometer has been developed to test the weak equivalence principle to a few parts in 10(15) within the framework of the general relativity accuracy test in an Einstein elevator experiment. The prototype sensor was designed to identify, address, and solve the major issues associated with various aspects of the experiment. This paper illustrates the measurements conducted on this prototype sensor to attain a high quality factor (Q ∼ 10(5)) at low frequencies (<20 Hz). Such a value is necessary for reducing the Brownian noise to match the target acceleration noise of 10(-14) g/√Hz, hence providing the desired experimental accuracy.

  1. High quality factor graphene varactors for wireless sensing applications

    NASA Astrophysics Data System (ADS)

    Koester, Steven J.

    2011-10-01

    A graphene wireless sensor concept is described. By utilizing thin gate dielectrics, the capacitance in a metal-insulator-graphene structure varies with charge concentration through the quantum capacitance effect. Simulations using realistic structural and transport parameters predict quality factors, Q, >60 at 1 GHz. When placed in series with an ideal inductor, a resonant frequency tuning ratio of 25% (54%) is predicted for sense charge densities ranging from 0.32 to 1.6 μC/cm2 at an equivalent oxide thickness of 2.0 nm (0.5 nm). The resonant frequency has a temperature sensitivity, df/dT, less than 0.025%/K for sense charge densities >0.32 μC/cm2.

  2. A case for the use of Q-methodology in disability research: lessons learned from a training workshop.

    PubMed

    McKenzie, Judith; Braswell, Bob; Jelsma, Jennifer; Naidoo, Nirmala

    2011-01-01

    Q-methodology was developed to analyse subjective responses to a range of items dealing with specific topics. This article describes the use of Q-methodology and presents the results of a Q-study on perspectives on disability carried out in a training workshop as evidence for its usefulness in disability research. A Q-sort was administered in the context of a training workshop on Q-method. The Q-sort consisted of statements related to the topic of disability. The responses were analysed using specifically developed software to identify factors that represent patterns of responses. Twenty-two of the 23 respondents loaded on four factors. These factors appeared to represent different paradigms relating to the social, medical and disability rights models of disability. The fourth factor appeared to be that of a family perspective. These are all models evident in the disability research literature and provide evidence for the validity of Q-method in disability research. Based on this opportunistic study, it would appear that Q-methodology is a useful tool for identifying different view points related to disability.

  3. An extra care community's perceived priorities for 'whole system' relationships: a Q-methodological study.

    PubMed

    Grimshaw, Paul; McGowan, Linda; McNichol, Elaine

    2017-05-01

    Health and social care settings worldwide need to sustainably improve the quality of relationships across communities or 'whole systems'. This research informs the development of a relational framework based on stakeholder perspectives. It is grounded in an action research project with practitioners, and draws on a previous literature review, to present the underpinning elements of quality relationships as statements, organised under the headings of integrity, respect, fairness, compassion and trust. Using Q methodology, 27 participants, comprising a range of stakeholders (staff, residents, family and service providers), rank-ordered 48 statements based on perceptions of the importance of differing aspects of relationships. By-person factor analysis was used to create five factors or viewpoints by comparing and contrasting using the composite rankings alongside interview data collected for each participant. The first view 'Altogether now' prioritises compassionate engagement. Second, 'Respect is a two-way street' emphasises the need for reciprocal respect and recognition of history. The factor labelled 'Free spirits' posits the dominant view of freedom. The fourth view 'Families … strengths and challenges' focuses on the necessary and complex involvement of families and finally, 'Helping hands' emphasises the role of relationships in increasing previously low expectations of social integration for previously isolated residents. The different views that exist on the composition of quality relationships can be used to help extra care communities to understand and utilise relationships as a powerful and effective resource. © 2017 John Wiley & Sons Ltd.

  4. A VLSI pipeline design of a fast prime factor DFT on a finite field

    NASA Technical Reports Server (NTRS)

    Truong, T. K.; Hsu, I. S.; Shao, H. M.; Reed, I. S.; Shyu, H. C.

    1986-01-01

    A conventional prime factor discrete Fourier transform (DFT) algorithm is used to realize a discrete Fourier-like transform on the finite field, GF(q sub n). A pipeline structure is used to implement this prime factor DFT over GF(q sub n). This algorithm is developed to compute cyclic convolutions of complex numbers and to decode Reed-Solomon codes. Such a pipeline fast prime factor DFT algorithm over GF(q sub n) is regular, simple, expandable, and naturally suitable for VLSI implementation. An example illustrating the pipeline aspect of a 30-point transform over GF(q sub n) is presented.

  5. Fluence-to-dose conversion coefficients for neutrons and protons calculated using the PHITS code and ICRP/ICRU adult reference computational phantoms.

    PubMed

    Sato, Tatsuhiko; Endo, Akira; Zankl, Maria; Petoussi-Henss, Nina; Niita, Koji

    2009-04-07

    The fluence to organ-dose and effective-dose conversion coefficients for neutrons and protons with energies up to 100 GeV was calculated using the PHITS code coupled to male and female adult reference computational phantoms, which are to be released as a common ICRP/ICRU publication. For the calculation, the radiation and tissue weighting factors, w(R) and w(T), respectively, as revised in ICRP Publication 103 were employed. The conversion coefficients for effective dose equivalents derived using the radiation quality factors of both Q(L) and Q(y) relationships were also estimated, utilizing the functions for calculating the probability densities of the absorbed dose in terms of LET (L) and lineal energy (y), respectively, implemented in PHITS. By comparing these data with the corresponding data for the effective dose, we found that the numerical compatibilities of the revised w(R) with the Q(L) and Q(y) relationships are fairly established. The calculated data of these dose conversion coefficients are indispensable for constructing the radiation protection systems based on the new recommendations given in ICRP103 for aircrews and astronauts, as well as for workers in accelerators and nuclear facilities.

  6. High-Q BBO whispering gallery mode resonators

    NASA Astrophysics Data System (ADS)

    Lin, Guoping; Fürst, Josef U.; Strekalov, Dmitry V.; Grudinin, Ivan S.; Yu, Nan

    2013-02-01

    We report an investigation on optical whispering gallery mode (WGM) resonators made from non z-cut beta barium borate (BBO) crystals. We first fabricated high quality (Q) factor WGM resonators made of an angle-cut BBO crystal. Q factors of 1×108 level have been demonstrated at various wavelengths including UV. They led to new upper bounds for the absorption coefficients of BBO at 1560 nm, 980 nm and 370 nm. We observed only one set of ordinarily polarized WGMs with polarization rotating along the resonator circumference. We also fabricated xy-cut BBO WGM resonators, in which the optic axis is parallel to the resonator plane. In that case, two WGM families with different polarization exist, one with constant the other with oscillatory phase velocity. This enables a novel way of broadband phase matching in WGM resonators with cyclic gain. We experimentally demonstrated efficient second harmonic generation (SHG) to a wide harmonic wavelength range from 780 nm at near infrared to 317 nm in UV. It is also the first reported direct UV SHG in a high-Q WGM resonator. This work lays a foundation for further investigations of WGM properties of non-z cut birefringent resonators and their applications in nonlinear optics.

  7. Measurements of the radiation quality factor Q at aviation altitudes during solar minimum (2006-2008)

    NASA Astrophysics Data System (ADS)

    Meier, Matthias M.; Hubiak, Melina

    2010-05-01

    In radiation protection, the Q-factor has been defined to describe the biological effectiveness of the energy deposition or absorbed dose to humans in the mixed radiation fields at aviation altitudes. This particular radiation field is generated by the interactions of primary cosmic particles with the atoms of the constituents of the Earth’s atmosphere. Thus the intensity, characterized by the ambient dose equivalent rate H∗(10), depends on the flight altitude and the energy spectra of the particles, mainly protons and alpha particles, impinging on the atmosphere. These charged cosmic projectiles are deflected both by the interplanetary and the Earth’s magnetic field such that the corresponding energy spectra are modulated by these fields. The solar minimum is a time period of particular interest since the interplanetary magnetic field is weakest within the 11-year solar cycle and the dose rates at aviation altitudes reach their maximum due to the reduced shielding of galactic cosmic radiation. For this reason, the German Aerospace Center (DLR) performed repeated dosimetric on-board measurements in cooperation with several German airlines during the past solar minimum from March 2006 to August 2008. The Q-factors measured with a TEPC range from 1.98 at the equator to 2.60 in the polar region.

  8. Clinical and psychosocial factors associated with quality of life in alcohol-dependent men with erectile dysfunction.

    PubMed

    Ponizovsky, Alexander M

    2008-10-01

    Men with alcohol dependence (AD) commonly suffer from alcohol-induced sexual (erectile) dysfunction (ED) and have poor quality of life (Qol). Knowledge about the factors associated with Qol in such patients is lacking. To identify in men who sought medical help for both AD and ED the variables that best predicted feelings of satisfaction with life and with specific life domains. The Quality of Life Enjoyment and Satisfaction Questionnaire (Q-LES-Q). Secondary study measures were the International Index of Erectile Function (IIEF), Beck Depression Inventory (BDI-13), General Health Questionnaire (GHQ-12), Rosenberg's General Self-Esteem Scale (RGSES), and the Multidimensional Scale of Perceived Social Support (MSPSS). Within an open-label sildenafil trial, 101 men aged 18-50 years with an International Classification of Diseases, Tenth Edition diagnosis of AD and concomitant ED were interviewed and completed the questionnaires. Multivariate analyses were applied to establish predictors of life satisfaction and factors mediating the relation between ED and life satisfaction. ED and self-rated depressive symptoms, emotional distress, self-esteem, and perceived social support were found to be significantly associated with Qol and its component domains. Altogether they explained 18-38% of the variance in the Qol ratings. Depressive symptomatology, distress, and self-esteem, individually, demonstrated a mediating effect on the relation between ED and Qol. Finally, self-esteem was shown to be the primary mediator in this relationship. The results of the study show that self-esteem is the primary factor, and depressive symptoms and severe emotional distress are secondary factors mediating the effects of ED on Qol in male patients seeking medical help for both AD and ED. An integrated pharmacopsychosocial approach targeting the underlying ED as well as the mediating emotional conditions could improve Qol of these patients and thus help them to stop using alcohol.

  9. Improving quality of arterial spin labeling MR imaging at 3 Tesla with a 32-channel coil and parallel imaging.

    PubMed

    Ferré, Jean-Christophe; Petr, Jan; Bannier, Elise; Barillot, Christian; Gauvrit, Jean-Yves

    2012-05-01

    To compare 12-channel and 32-channel phased-array coils and to determine the optimal parallel imaging (PI) technique and factor for brain perfusion imaging using Pulsed Arterial Spin labeling (PASL) at 3 Tesla (T). Twenty-seven healthy volunteers underwent 10 different PASL perfusion PICORE Q2TIPS scans at 3T using 12-channel and 32-channel coils without PI and with GRAPPA or mSENSE using factor 2. PI with factor 3 and 4 were used only with the 32-channel coil. Visual quality was assessed using four parameters. Quantitative analyses were performed using temporal noise, contrast-to-noise and signal-to-noise ratios (CNR, SNR). Compared with 12-channel acquisition, the scores for 32-channel acquisition were significantly higher for overall visual quality, lower for noise and higher for SNR and CNR. With the 32-channel coil, artifact compromise achieved the best score with PI factor 2. Noise increased, SNR and CNR decreased with PI factor. However mSENSE 2 scores were not always significantly different from acquisition without PI. For PASL at 3T, the 32-channel coil at 3T provided better quality than the 12-channel coil. With the 32-channel coil, mSENSE 2 seemed to offer the best compromise for decreasing artifacts without significantly reducing SNR, CNR. Copyright © 2012 Wiley Periodicals, Inc.

  10. Hadronic Form Factors in Asymptotically Free Field Theories

    DOE R&D Accomplishments Database

    Gross, D. J.; Treiman, S. B.

    1974-01-01

    The breakdown of Bjorken scaling in asymptotically free gauge theories of the strong interactions is explored for its implications on the large q{sup 2} behavior of nucleon form factors. Duality arguments of Bloom and Gilman suggest a connection between the form factors and the threshold properties of the deep inelastic structure functions. The latter are addressed directly in an analysis of asymptotically free theories; and through the duality connection we are then led to statements about the form factors. For very large q{sup 2} the form factors are predicted to fall faster than any inverse power of q{sup 2}. For the more modest range of q{sup 2} reached in existing experiments the agreement with data is fairly good, though this may well be fortuitous. Extrapolations beyond this range are presented.

  11. Predictors of mother-child interaction quality and child attachment security in at-risk families.

    PubMed

    De Falco, Simona; Emer, Alessandra; Martini, Laura; Rigo, Paola; Pruner, Sonia; Venuti, Paola

    2014-01-01

    Child healthy development is largely influenced by parent-child interaction and a secure parent-child attachment is predictively associated with positive outcomes in numerous domains of child development. However, the parent-child relationship can be affected by several psychosocial and socio-demographic risk factors that undermine its quality and in turn play a negative role in short and long term child psychological health. Prevention and intervention programs that support parenting skills in at-risk families can efficiently reduce the impact of risk factors on mother and child psychological health. This study examines predictors of mother-child interaction quality and child attachment security in a sample of first-time mothers with psychosocial and/or socio-demographic risk factors. Forty primiparous women satisfying specific risk criteria participated in a longitudinal study with their children from pregnancy until 18 month of child age. A multiple psychological and socioeconomic assessment was performed. The Emotional Availability Scales were used to measure the quality of emotional exchanges between mother and child at 12 months and the Attachment Q-Sort served as a measure of child attachment security at 18 months. Results highlight both the effect of specific single factors, considered at a continuous level, and the cumulative risk effect of different co-occurring factors, considered at binary level, on mother-child interaction quality and child attachment security. Implication for the selection of inclusion criteria of intervention programs that support parenting skills in at-risk families are discussed.

  12. Characteristic analysis and comparison of two kinds of hybrid plasmonic annular resonators

    NASA Astrophysics Data System (ADS)

    Zhou, Jie; Shi, Feifei; Zhou, Taojie; He, Kebo; Qiu, Bocang; Zhang, Zhaoyu

    2017-04-01

    We designed two kinds of hybrid plasmonic annular resonators with different cross-sectional shapes, i.e., a square and circle called "square ring" and "circle ring" resonators, respectively. Both resonators feature an ultracompact mode volume of ˜10-4 μm3 and a relatively high-quality factor of ˜102 at a submicron footprint within our studied wavelength range from 400 to 900 nm. Their performance as defined by the Q/V ratio (quality factor over mode volume) is enhanced considerably with a reduction in their physical dimensions. There exists critical annular radii, which increase from 400 to 600 nm with an increase in the azimuthal numbers from m=7 to m=10, if the two types of rings are compared with the same mode numbers and same ring thickness of 120 nm. Below the critical radii, the circle ring resonator outperforms the square ring resonator in terms of the Q/V ratio, and the difference in Q/V of the two types of rings increases rapidly with the decrease of the radii. On the other hand, they have critical annular radii of ˜250 nm, below which the square ring resonator outperforms the circle ring resonator at the wavelengths of 490 and 595 nm however, the difference in Q/V of the two types of rings remains small within the radii range we consider. It is suggested that, in practice, with the consideration of the wavelength of green emission for these two ring structures with radii from 100 to 500 nm and ring thickness ˜120 nm, they have a negligible difference in Q/V performance.

  13. DNA copy number gains at loci of growth factors and their receptors in salivary gland adenoid cystic carcinoma.

    PubMed

    Vékony, Hedy; Ylstra, Bauke; Wilting, Saskia M; Meijer, Gerrit A; van de Wiel, Mark A; Leemans, C René; van der Waal, Isaäc; Bloemena, Elisabeth

    2007-06-01

    Adenoid cystic carcinoma (ACC) is a malignant salivary gland tumor with a high mortality rate due to late, distant metastases. This study aimed at unraveling common genetic abnormalities associated with ACC. Additionally, chromosomal changes were correlated with patient characteristics and survival. Microarray-based comparative genomic hybridization was done to a series of 18 paraffin-embedded primary ACCs using a genome-wide scanning BAC array. A total of 238 aberrations were detected, representing more gains than losses (205 versus 33, respectively). Most frequent gains (>60%) were observed at 9q33.3-q34.3, 11q13.3, 11q23.3, 19p13.3-p13.11, 19q12-q13.43, 21q22.3, and 22q13.33. These loci harbor numerous growth factor [fibroblast growth factor (FGF) and platelet-derived growth factor (PDGF)] and growth factors receptor (FGFR3 and PDGFRbeta) genes. Gains at the FGF(R) regions occurred significantly more frequently in the recurred/metastasized ACCs compared with indolent ACCs. Furthermore, patients with 17 or more chromosomal aberrations had a significantly less favorable outcome than patients with fewer chromosomal aberrations (log-rank = 5.2; P = 0.02). Frequent DNA copy number gains at loci of growth factors and their receptors suggest their involvement in ACC initiation and progression. Additionally, the presence of FGFR3 and PDGFRbeta in increased chromosomal regions suggests a possible role for autocrine stimulation in ACC tumorigenesis.

  14. Optimal dielectric and cavity configurations for improving the efficiency of electron paramagnetic resonance probes

    NASA Astrophysics Data System (ADS)

    Elnaggar, Sameh Y.; Tervo, Richard; Mattar, Saba M.

    2014-08-01

    An electron paramagnetic resonance (EPR) spectrometer’s lambda efficiency parameter (Λ) is one of the most important parameters that govern its sensitivity. It is studied for an EPR probe consisting of a dielectric resonator (DR) in a cavity (CV). Expressions for Λ are derived in terms of the probe’s individual DR and CV components, Λ1 and Λ2 respectively. Two important cases are considered. In the first, a probe consisting of a CV is improved by incorporating a DR. The sensitivity enhancement depends on the relative rather than the absolute values of the individual components. This renders the analysis general. The optimal configuration occurs when the CV and DR modes are nearly degenerate. This configuration guarantees that the probe can be easily coupled to the microwave bridge while maintaining a large Λ. It is shown that for a lossy CV with a small quality factor Q2, one chooses a DR that has the highest filling factor, η1, regardless of its Λ1 and Q1. On the other hand, if the CV has a large Q2, the optimum DR is the one which has the highest Λ1. This is regardless of its η1 and relative dielectric constant, ɛr. When the quality factors of both the CV and DR are comparable, the lambda efficiency is reduced by a factor of √{2}. Thus the signal intensity for an unsaturated sample is cut in half. The second case is the design of an optimum shield to house a DR. Besides preventing radiation leakage, it is shown that for a high loss DR, the shield can actually boost Λ above the DR value. This can also be very helpful for relatively low efficiency dielectrics as well as lossy samples, such as polar liquids.

  15. Two-Stage Design Method for Enhanced Inductive Energy Transmission with Q-Constrained Planar Square Loops.

    PubMed

    Eteng, Akaa Agbaeze; Abdul Rahim, Sharul Kamal; Leow, Chee Yen; Chew, Beng Wah; Vandenbosch, Guy A E

    2016-01-01

    Q-factor constraints are usually imposed on conductor loops employed as proximity range High Frequency Radio Frequency Identification (HF-RFID) reader antennas to ensure adequate data bandwidth. However, pairing such low Q-factor loops in inductive energy transmission links restricts the link transmission performance. The contribution of this paper is to assess the improvement that is reached with a two-stage design method, concerning the transmission performance of a planar square loop relative to an initial design, without compromise to a Q-factor constraint. The first stage of the synthesis flow is analytical in approach, and determines the number and spacing of turns by which coupling between similar paired square loops can be enhanced with low deviation from the Q-factor limit presented by an initial design. The second stage applies full-wave electromagnetic simulations to determine more appropriate turn spacing and widths to match the Q-factor constraint, and achieve improved coupling relative to the initial design. Evaluating the design method in a test scenario yielded a more than 5% increase in link transmission efficiency, as well as an improvement in the link fractional bandwidth by more than 3%, without violating the loop Q-factor limit. These transmission performance enhancements are indicative of a potential for modifying proximity HF-RFID reader antennas for efficient inductive energy transfer and data telemetry links.

  16. Prevalence of illness, poor mental health and sleep quality and low energy availability prior to the 2016 Summer Olympic Games.

    PubMed

    Drew, Michael; Vlahovich, Nicole; Hughes, David; Appaneal, Renee; Burke, Louise M; Lundy, Bronwen; Rogers, Margot; Toomey, Mary; Watts, David; Lovell, Gregory; Praet, Stephan; Halson, Shona L; Colbey, Candice; Manzanero, Silvia; Welvaert, Marijke; West, Nicholas P; Pyne, David B; Waddington, Gordon

    2018-01-01

    Establish the prevalence of illness symptoms, poor sleep quality, poor mental health symptoms, low energy availability and stress-recovery state in an Olympic cohort late in the 3 months prior to the Summer Olympic Games. Olympic athletes (n=317) from 11 sports were invited to complete questionnaires administered 3 months before the Rio 2016 Olympic Games. These questionnaires included the Depression, Anxiety and Stress Questionnaire, Perceived Stress Scale, Dispositional Resilience Scale, Recovery-Stress Questionnaire (REST-Q-52 item), Low Energy Availability in Females Questionnaire (LEAF-Q), Epworth Sleepiness Scale, Pittsburgh Sleep Quality Index and custom-made questionnaires on probiotic usage and travel. Multiple illness (case) definitions were applied. ORs and attributable fractions in the population were used. Factor analyses were used to explore the relationships between variables. The response rate was of 42% (male, n=47, age 25.8±4.1 years; female, n=85, age 24.3±3.9 years). Low energy availability was associated with sustaining an illness in the previous month (upper respiratory, OR=3.8, 95% CI 1.2 to 12). The main factor relating to illness pertained to a combination of anxiety and stress-recovery states (as measured by the REST-Q-52 item). All participants reported at least one episode of illness in the last month (100% prevalence). All participants reported at least one illness symptom in the previous month. Low energy availability was a leading variable associated with illness in Olympic-class athletes. The estimates duration of symptoms ranged from 2 to 7 days. Factor analyses show the interdependence of various health domains and support multidisciplinary care. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. A quantitative theory of the Hounsfield unit and its application to dual energy scanning.

    PubMed

    Brooks, R A

    1977-10-01

    A standard definition is proposed for the Hounsfield number. Any number in computed tomography can be converted to the Hounsfield scale after performing a simple calibration using air and water. The energy dependence of the Hounsfield number, H, is given by the expression H = (Hc + Hp Q)/(1 + Q), where Hc and Hp are the Compton and photoelectric coefficients of the material being measured, expressed in Hounsfield units, and Q is the "quality factor" of the scanner. Q can be measured by performing a scan of a single calibrating material, such as a potassium iodine solution. By applying this analysis to dual energy scans, the Compton and photoelectric coefficients of an unknown substance may easily be obtained. This can lead to a limited degree of chemical identification.

  18. Directly q-switched high power resonator based on XLMA-fibers

    NASA Astrophysics Data System (ADS)

    Giesberts, M.; Fitzau, O.; Hoffmann, H.-D.; Lange, R.; Bachert, C.; Krause, V.

    2018-02-01

    In this paper we present a simple approach to achieving nanosecond pulses from a directly q-switched high-power resonator based on extra-large mode area (XLMA) fibers with a beam quality factor M2 < 15. An average output power of > 500 W has been demonstrated for repetition frequencies between 50-100 kHz. The resonator consists of a single fiber q-switched with soldered Pockels-cells which exhibit a very high contrast ratio leading to output pulses down to about 10 ns and peak powers up to > 250 kW at 1064 nm wavelength. By using this design instead of a fiber MOPA setup, a cost-effective and less complex system could be implemented.

  19. Up, down, and strange nucleon axial form factors from lattice QCD

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Green, Jeremy; Hasan, Nesreen; Meinel, Stefan

    Here, we report a calculation of the nucleon axial form factorsmore » $$G_A^q(Q^2)$$ and $$G_P^q(Q^2)$$ for all three light quark flavors $$q\\in\\{u,d,s\\}$$ in the range $$0\\leq Q^2\\lesssim 1.2\\text{ GeV}^2$$ using lattice QCD. Our work was done using a single ensemble with pion mass 317 MeV and made use of the hierarchical probing technique to efficiently evaluate the required disconnected loops. We perform nonperturbative renormalization of the axial current, including a nonperturbative treatment of the mixing between light and strange currents due to the singlet-nonsinglet difference caused by the axial anomaly. The form factor shapes are fit using the model-independent $z$ expansion. From $$G_A^q(Q^2)$$, we determine the quark contributions to the nucleon spin and axial radii. By extrapolating the isovector $$G_P^{u-d}(Q^2)$$, we obtain the induced pseudoscalar coupling relevant for ordinary muon capture and the pion-nucleon coupling constant. We also found that the disconnected contributions to $$G_P$$ form factors are large, and give an interpretation based on the dominant influence of the pseudoscalar poles in these form factors.« less

  20. Up, down, and strange nucleon axial form factors from lattice QCD

    DOE PAGES

    Green, Jeremy; Hasan, Nesreen; Meinel, Stefan; ...

    2017-06-14

    Here, we report a calculation of the nucleon axial form factorsmore » $$G_A^q(Q^2)$$ and $$G_P^q(Q^2)$$ for all three light quark flavors $$q\\in\\{u,d,s\\}$$ in the range $$0\\leq Q^2\\lesssim 1.2\\text{ GeV}^2$$ using lattice QCD. Our work was done using a single ensemble with pion mass 317 MeV and made use of the hierarchical probing technique to efficiently evaluate the required disconnected loops. We perform nonperturbative renormalization of the axial current, including a nonperturbative treatment of the mixing between light and strange currents due to the singlet-nonsinglet difference caused by the axial anomaly. The form factor shapes are fit using the model-independent $z$ expansion. From $$G_A^q(Q^2)$$, we determine the quark contributions to the nucleon spin and axial radii. By extrapolating the isovector $$G_P^{u-d}(Q^2)$$, we obtain the induced pseudoscalar coupling relevant for ordinary muon capture and the pion-nucleon coupling constant. We also found that the disconnected contributions to $$G_P$$ form factors are large, and give an interpretation based on the dominant influence of the pseudoscalar poles in these form factors.« less

  1. Monte Carlo calculations of electron beam quality conversion factors for several ion chamber types.

    PubMed

    Muir, B R; Rogers, D W O

    2014-11-01

    To provide a comprehensive investigation of electron beam reference dosimetry using Monte Carlo simulations of the response of 10 plane-parallel and 18 cylindrical ion chamber types. Specific emphasis is placed on the determination of the optimal shift of the chambers' effective point of measurement (EPOM) and beam quality conversion factors. The EGSnrc system is used for calculations of the absorbed dose to gas in ion chamber models and the absorbed dose to water as a function of depth in a water phantom on which cobalt-60 and several electron beam source models are incident. The optimal EPOM shifts of the ion chambers are determined by comparing calculations of R50 converted from I50 (calculated using ion chamber simulations in phantom) to R50 calculated using simulations of the absorbed dose to water vs depth in water. Beam quality conversion factors are determined as the calculated ratio of the absorbed dose to water to the absorbed dose to air in the ion chamber at the reference depth in a cobalt-60 beam to that in electron beams. For most plane-parallel chambers, the optimal EPOM shift is inside of the active cavity but different from the shift determined with water-equivalent scaling of the front window of the chamber. These optimal shifts for plane-parallel chambers also reduce the scatter of beam quality conversion factors, kQ, as a function of R50. The optimal shift of cylindrical chambers is found to be less than the 0.5 rcav recommended by current dosimetry protocols. In most cases, the values of the optimal shift are close to 0.3 rcav. Values of kecal are calculated and compared to those from the TG-51 protocol and differences are explained using accurate individual correction factors for a subset of ion chambers investigated. High-precision fits to beam quality conversion factors normalized to unity in a beam with R50 = 7.5 cm (kQ (')) are provided. These factors avoid the use of gradient correction factors as used in the TG-51 protocol although a chamber dependent optimal shift in the EPOM is required when using plane-parallel chambers while no shift is needed with cylindrical chambers. The sensitivity of these results to parameters used to model the ion chambers is discussed and the uncertainty related to the practical use of these results is evaluated. These results will prove useful as electron beam reference dosimetry protocols are being updated. The analysis of this work indicates that cylindrical ion chambers may be appropriate for use in low-energy electron beams but measurements are required to characterize their use in these beams.

  2. 'An exploration of the health beliefs of Chinese nurses' and nurse academics' health beliefs: A Q-methodology study'.

    PubMed

    Cai, Dan; Stone, Teresa E; Petrini, Marcia A; McMillan, Margaret

    2016-03-01

    Q-methodology was used to investigate the health beliefs of Chinese clinical nurses and nurse academics. Twenty-eight participants from one hospital and nursing school in China were involved. The four stages of this study included: (i) concourse development from literature review, Internet searches, and key informant interviews; (ii) A pilot study to develop the Q-sample from the concourse; (iii) participants sorted the Q-sample statements along a continuum of preference (Q-sorting); and (iv) PQ data analysis using principal component analysis and varimax rotation. Five viewpoints were revealed: (i) factor 1--health management and the importance of evidence; (ii) factor 2--challenging local cultural belief, and Eastern and Western influences; (iii) factor 3--commonsense; (iv) factor 4--health and clinical practice; and (v) factor 5--health and nursing education. This study presents a need for nurses and nurse academics to think critically, examine their long-held health beliefs, and promote the use of evidence-based practice. © 2016 Wiley Publishing Asia Pty Ltd.

  3. Characteristic Processes in Close Peer Friendships of Preterm Infants at Age 12

    PubMed Central

    Sullivan, Mary C.; Barcelos Winchester, Suzy; Parker, Jeffrey G.; Marks, Amy K.

    2012-01-01

    Close friendships become important at middle-school age and are unexplored in adolescents born prematurely. The study aimed to characterize friendship behaviors of formerly preterm infants at age 12 and explore similarities and differences between preterm and full-term peers on dyadic friendship types. From the full sample of N = 186, one hundred sixty-six 12-year-old adolescents (40 born full term, 126 born preterm) invited a close friend to a 1.5 hour videotaped laboratory play session. Twenty adolescents were unable to participate due to scheduling conflicts or developmental disability. Characteristic friendship behaviors were identified by Q-sort followed by Q-factoring analysis. Friendship duration, age, and contact differed between the full-term and preterm groups but friendship activities, behaviors, and quality were similar despite school service use. Three Q-factors, leadership, distancing, and mutual playfulness, were most characteristic of all dyads, regardless of prematurity. These prospective, longitudinal findings demonstrate diminished prematurity effects at adolescence in peer friendship behavior and reveal interpersonal dyadic processes that are important to peer group affiliation and other areas of competence. PMID:23308346

  4. High-Q silica zipper cavity for optical radiation pressure driven MOMS switch

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tetsumoto, Tomohiro; Tanabe, Takasumi, E-mail: takasumi@elec.keio.ac.jp

    2014-07-15

    We design a silica zipper cavity that has high optical and mechanical Q (quality factor) values and demonstrate numerically the feasibility of a radiation pressure driven micro opto-mechanical system (MOMS) directional switch. The silica zipper cavity has an optical Q of 4.0 × 10{sup 4} and an effective mode volume V{sub mode} of 0.67λ{sup 3} when the gap between two cavities is 34 nm. The mechanical Q (Q{sub m}) is determined by thermo-elastic damping and is 2.0 × 10{sup 6} in a vacuum at room temperature. The opto-mechanical coupling rate g{sub OM} is as high as 100 GHz/nm, which allowsmore » us to move the directional cavity-waveguide system and switch 1550-nm light with 770-nm light by controlling the radiation pressure.« less

  5. Discovery and identification of quality markers of Chinese medicine based on pharmacokinetic analysis.

    PubMed

    He, Jun; Feng, Xinchi; Wang, Kai; Liu, Changxiao; Qiu, Feng

    2018-02-28

    Quality control of Chinese medicine (CM) is an effective measure to ensure the safety and efficacy of CM in clinical practice, which is also a key factor to restrict the modernization process of CM. Various chemical components exist in CM and the determination of several chemical components is the main approach for quality control of vast majority of CM in the present. However, many components determined lack not only specificity, but also biological activities. This is bound to greatly reduce the actual value of quality standard of CM. Professor Changxiao Liu proposed the "quality marker" (Q-marker) concept to ensure the standardization and rationalization for the quality control of CM. As we all know, CMs are taken orally in most cases and could be extensively metabolized in vivo. Both prototype components and the metabolites could be the actual therapeutic material basis. Pharmacokinetic studies could benefit the elucidation of actual therapeutic material basis which is closely related to the identification of Q-markers. Therefore, a new strategy about Q-marker was proposed based on the pharmacokinetic analysis of CM, hoping to provide some ideas for the discovery and identification of Q-marker. The relationship between pharmacokinetic studies and the identification of Q-markers was demonstrated in this review and a new strategy was proposed. Starting from the pharmacokinetic analysis, reverse tracing of the prototype active components and the potential prodrugs in CM were conducted first and the therapeutic material basis were identified as Q-markers. Then, modern analytical techniques and methods were applied to obtain comprehensive quality control for these constituents. Several CMs including gingko biloba, ginseng, Periplocae Cortex, Mori Cortex, Bupleuri Radix and Scutellariae Radix were listed as examples to clarify how the new strategy could be applied. Pharmacokinetic studies play an important role for the elucidation of therapeutic material basis of CM and the identification of Q-markers and it should be taken into account during the process of the investigation of Q-marker. Copyright © 2018 Elsevier GmbH. All rights reserved.

  6. Impurity Content Optimization to Maximize Q-Factors of Superconducting Resonators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martinello, Martina; Checchin, Mattia; Grassellino, Anna

    2017-05-01

    Quality factor of superconducting radio-frequency (SRF) cavities is degraded whenever magnetic flux is trapped in the cavity walls during the cooldown. In this contribution we study how the trapped flux sensitivity, defined as the trapped flux surface resistance normalized for the amount of trapped flux, depends on the mean free path. A systematic study of a variety of 1.3 GHz cavities with different surface treatments (EP, 120 C bake and different N-doping) is carried out. A bell shaped trend appears for the range of mean free path studied. Over-doped cavities fall at the maximum of this curve defining the largestmore » values of sensitivity. In addition, we have studied the trend of the BCS surface resistance contribution as a function of mean free path, showing that N-doped cavities follow close to the theoretical minimum. Adding these results together we show that the 2/6 N-doping treatment gives the highest Q-factor values at 2 K and 16 MV/m, as long as the magnetic field fully trapped during the cavity cooldown is lower than 10 mG.« less

  7. Factor analysis of the adolescent version of the Eating Disorders Examination Questionnaire (EDE-Q): results from Swedish general population and clinical samples.

    PubMed

    Forsén Mantilla, Emma; Birgegård, Andreas; Clinton, David

    2017-01-01

    Although the Eating Disorder Examination Questionnaire (EDE-Q) is perhaps the single most widely used self-report measure of eating disorder (ED) symptoms, important questions remain about its validity and applicability in relation to particular groups of individuals, especially adolescents of both genders. The present study investigated the factor structure of the adolescent version of the Eating Disorder Examination Questionnaire (EDE-Q) in samples of Swedish girls and boys from the general population and girls with a diagnosed eating disorder. Girls ( N  = 239) and boys ( N  = 248) aged between 13 and 15 years who were attending school, and girls ( N  = 570) aged between 12 and 14 years who were in treatment for an eating disorder at a specialist eating disorder clinic were assessed on the adolescent version of the EDE-Q. The adolescent version of the EDE-Q demonstrated satisfactory levels of internal consistency. However, confirmatory factor analysis (CFA) failed to support the four-factor model of the EDE-Q. Parallel analysis (PA) and subsequent exploratory factor analysis (EFA) suggested that the adolescent version of the EDE-Q comprises one underlying factor in young adolescent girls (both clinical and general population), centred on Dissatisfaction with Shape and Weight. In boys three factors were found: Weight-related Concerns, Body Discomfort and Restraint. The EDE-Q appears to measure different underlying aspects of eating disorder psychopathology in young teenagers compared to adults. The dimensions underlying disordered eating in young girls may become increasingly differentiated with time. There appear to be important gender-based differences in the dimensions underlying the EDE-Q in young teenagers. Therapists should be alert to beliefs that girls have about the importance of shape and weight, while in boys it may be more important to be attentive to how they feel about their bodies in relation to weight.

  8. Precession relaxation of viscoelastic oblate rotators

    NASA Astrophysics Data System (ADS)

    Frouard, Julien; Efroimsky, Michael

    2018-01-01

    Perturbations of all sorts destabilize the rotation of a small body and leave it in a non-principal spin state. In such a state, the body experiences alternating stresses generated by the inertial forces. This yields nutation relaxation, i.e. evolution of the spin towards the principal rotation about the maximal-inertia axis. Knowledge of the time-scales needed to damp the nutation is crucial in studies of small bodies' dynamics. In the literature hitherto, nutation relaxation has always been described with aid of an empirical quality factor Q introduced to parametrize the energy dissipation rate. Among the drawbacks of this approach was its inability to describe the dependence of the relaxation rate upon the current nutation angle. This inability stemmed from our lack of knowledge of the quality factor's dependence on the forcing frequency. In this article, we derive our description of nutation damping directly from the rheological law obeyed by the material. This renders us the nutation damping rate as a function of the current nutation angle, as well as of the shape and the rheological parameters of the body. In contradistinction from the approach based on an empirical Q factor, our development gives a zero damping rate in the spherical-shape limit. Our method is generic and applicable to any shape and to any linear rheological law. However, to simplify the developments, here we consider a dynamically oblate rotator with a Maxwell rheology.

  9. Confirmatory factor analysis of the Eating Disorder Examination-Questionnaire: A comparison of five factor solutions across vegan and omnivore participants.

    PubMed

    Heiss, Sydney; Boswell, James F; Hormes, Julia M

    2018-05-01

    The Eating Disorder Examination-Questionnaire (EDE-Q) is a valid and reliable measure of eating-related pathology, but its factor structure has proven difficult to replicate. Given differences in dietary patterns in vegans compared to omnivores, proper measurement of eating disorder symptoms is especially important in studies of animal product avoiders. This study compared goodness-of-fit of five alternative models of the EDE-Q in vegans (i.e., individuals refraining from all animal products, n = 318) and omnivores (i.e., individuals not restricting intake of animal products, n = 200). Confirmatory factor analyses were used to compare fit indices of the original four-factor model of the EDE-Q, along with alternative three-, two-, full one-, and brief one-factor models. No model provided adequate fit of the data in either sample of respondents. The fit of the brief one-factor model was the closest to acceptable in omnivores, but did not perform as well in vegans. Indicators of fit were comparable in vegans and omnivores across all other models. Our data confirm difficulties in replicating the proposed factor structure of the EDE-Q, including in vegans. More research is needed to determine the suitability of the EDE-Q for quantifying eating behaviors, including in those abstaining from animal products. © 2018 Wiley Periodicals, Inc.

  10. Monolithic optofluidic ring resonator lasers created by femtosecond laser nanofabrication.

    PubMed

    Chandrahalim, Hengky; Chen, Qiushu; Said, Ali A; Dugan, Mark; Fan, Xudong

    2015-05-21

    We designed, fabricated, and characterized a monolithically integrated optofluidic ring resonator laser that is mechanically, thermally, and chemically robust. The entire device, including the ring resonator channel and sample delivery microfluidics, was created in a block of fused-silica glass using a 3-dimensional femtosecond laser writing process. The gain medium, composed of Rhodamine 6G (R6G) dissolved in quinoline, was flowed through the ring resonator. Lasing was achieved at a pump threshold of approximately 15 μJ mm(-2). Detailed analysis shows that the Q-factor of the optofluidic ring resonator is 3.3 × 10(4), which is limited by both solvent absorption and scattering loss. In particular, a Q-factor resulting from the scattering loss can be as high as 4.2 × 10(4), suggesting the feasibility of using a femtosecond laser to create high quality optical cavities.

  11. Design and analysis of a high Q MEMS passive RF filter

    NASA Astrophysics Data System (ADS)

    Rathee, Vishal; Pande, Rajesh

    2016-04-01

    Over the past few years, significant growth has been observed in using MEMS based passive components in the RF microelectronics domain, especially in transceiver system. This is due to some excellent properties of the MEMS devices like low loss, low cost and excellent isolation. This paper presents a design of high performance MEMS passive band pass filter, consisting of L and C with improved quality factor and insertion loss less than the reported filters. In this paper we have presented a design of 2nd order band pass filter with 2.4GHz centre frequency and 83MHz bandwidth for Bluetooth application. The simulation results showed improved Q-factor of 34 and Insertion loss of 1.7dB to 1.9dB. The simulation results needs to be validated by fabricating the device, fabrication flow of which is also presented in the paper.

  12. Comparisons of Integrated Radiation Transport Models with Microdosimetry Data in Spaceflight

    NASA Technical Reports Server (NTRS)

    Cucinotta, Francis A.; Nikjoo, H.; Kim, M. Y.; Hu, X.; Dicello, J. F.; Pisacane, V. L.

    2006-01-01

    Astronauts are exposed to galactic cosmic rays (GCR), trapped protons, and possible solar particle events (SPE) during spaceflight. For such complicated mixtures of radiation types and kinetic energies, tissue equivalent proportional counters (TEPC's) represent a simple time-dependent approach for radiation monitoring. Of interest in radiation protection is the average quality factor of a radiation field defined as a function of linear energy transfer, LET, Q(sub ave)(LET). However TEPC's measure the average quality factors as a function of lineal energy (y), Q(sub ave)(y) defined as the average energy deposition in a volume divided by the average chord length of the volume. Lineal energy, y deviates from LET due to energy straggling, delta-ray escape or entry, and nuclear fragments produced in the detector. Using integrated space radiation models that includes the transport code HZETRN/BRYNTRN, the quantum nuclear interaction model, QMSFRG, and results from Monte-Carlo track simulations of TEPC's response to ions, we consider comparisons of model calculations to TEPC results from NASA missions in low Earth orbit and make predictions for lunar and Mars missions. Good agreement between the model and measured spectra from past NASA missions is found. A finding of this work is that TEPC's values for trapped or solar protons of Q(sub ave)(y) range from 1.9-2.5, overestimating Q(sub ave)(LET), which ranges from 1.4-1.6 with both quantities increasing with shielding depth due to nuclear secondaries Comparisons for the complete GCR spectra show that Q(sub ave)(LET) for GCR is approximately 3.5-4.5, while TEPC's measure 2.9-3.4 for Q(sub ave)(y) with the GCR values decreasing with depth as heavy ions are absorbed in shielding material. Our results support the use of TEPC's for space radiation environmental monitoring when computational analysis is used for proper data interpretation.

  13. Tunneling study of SRF cavity-grade niobium.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Proslier, T.; Zasadzinski, J.; Cooley, L.

    Niobium, with its very high H{sub C1}, has been used in superconducting radio frequency (SRF) cavities for accelerator systems for 40 years with continual improvement. The quality factor of cavities (Q) is governed by the surface impedance R{sub BCS}, which depends on the quasiparticle gap, delta, and the superfluid density. Both of these parameters are seriously affected by surface imperfections (metallic phases, dissolved oxygen, magnetic impurities). Loss mechanism and surface treatments of Nb cavities found to improve the Q factor are still unsolved mysteries. We present here an overview of the capabilities of the point contact tunneling spectroscopy and Atomicmore » layer deposition methods and how they can help understanding the High field Q-drop and the mild baking effect. Tunneling spectroscopy was performed on Nb pieces from the same processed material used to fabricate SRF cavities. Air exposed, electropolished Nb exhibited a surface superconducting gap Delta = 1.55 meV, characteristic of clean, bulk Nb, however the tunneling density of states (DOS) was broadened significantly. Nb pieces treated with the same mild baking used to improve the Q-slope in SRF cavities revealed a much sharper DOS. Good fits to the DOS are obtained using Shiba theory suggesting that magnetic scattering of quasiparticles is the origin of the degraded surface superconductivity and the Q-slope problem of Nb SRF cavities.« less

  14. Nanomaterial-enhanced frequency combs (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Armani, Andrea M.; Castro-Beltran, Rigoberto; Diep, Vinh; Gungor, Eda; Shen, Xiaoqin; Soltani, Soheil

    2017-02-01

    Optical cavities are able to confine and store specific wavelengths of light, acting as optical amplifiers at those wavelengths. Because the amount of amplification is directly related to the cavity quality factor (Q) (or the cavity finesse), frequency comb research has focused on high-Q and ultra-high Q microcavities fabricated from a range of materials using a variety of methods. In all cases, the comb generation relies on a nonlinear process known as parametric frequency conversion which is based on a third order nonlinear interaction and which results in four wave mixing (FWM). Clearly, this approach requires significant optical power, which was the original motivation for using ultra-high-Q cavities. In fact, the majority of research to date has focused on pursuing increasingly high Q factors. However, another strategy is to improve the nonlinearity of the resonator through intelligently designing materials for this application. In the present work, a suite of nanomaterials (organic and inorganic) have been intelligently designed with the explicit purpose to enhance the nonlinearity of the resonator and reducing the threshold for frequency comb generation in the near-IR. The nanomaterials do not change the structure of the comb and only act to reduce the comb threshold. The silica microcavity is used as a testbed for initial demonstration and verification purposes. However, the fundamental strategy is translatable to other whispering gallery mode cavities.

  15. Trends and risk factors for human Q fever in Australia, 1991-2014.

    PubMed

    Sloan-Gardner, T S; Massey, P D; Hutchinson, P; Knope, K; Fearnley, E

    2017-03-01

    Australian abattoir workers, farmers, veterinarians and people handling animal birthing products or slaughtering animals continue to be at high risk of Q fever despite an effective vaccine being available. National Notifiable Diseases Surveillance System data were analysed for the period 1991-2014, along with enhanced risk factor data from notified cases in the states of New South Wales and Queensland, to examine changes in the epidemiology of Q fever in Australia. The national Q fever notification rate reduced by 20% [incident rate ratio (IRR) 0·82] following the end of the National Q fever Management Program in 2006, and has increased since 2009 (IRR 1·01-1·34). Highest rates were in males aged 40-59 years (5·9/100 000) and 87% of Q fever cases occurred in New South Wales and Queensland. The age of Q fever cases and proportion of females increased over the study period. Based on the enhanced risk factor data, the most frequently listed occupation for Q fever cases involved contact with livestock, followed by 'no known risk' occupations. More complete and comparable enhanced risk factor data, at the State/Territory and national levels, would aid in further understanding of the epidemiology of Q fever.

  16. Light meson form factors at high Q2 from lattice QCD

    NASA Astrophysics Data System (ADS)

    Koponen, Jonna; Zimermmane-Santos, André; Davies, Christine; Lepage, G. Peter; Lytle, Andrew

    2018-03-01

    Measurements and theoretical calculations of meson form factors are essential for our understanding of internal hadron structure and QCD, the dynamics that bind the quarks in hadrons. The pion electromagnetic form factor has been measured at small space-like momentum transfer |q2| < 0.3 GeV2 by pion scattering from atomic electrons and at values up to 2.5 GeV2 by scattering electrons from the pion cloud around a proton. On the other hand, in the limit of very large (or infinite) Q2 = -q2, perturbation theory is applicable. This leaves a gap in the intermediate Q2 where the form factors are not known. As a part of their 12 GeV upgrade Jefferson Lab will measure pion and kaon form factors in this intermediate region, up to Q2 of 6 GeV2. This is then an ideal opportunity for lattice QCD to make an accurate prediction ahead of the experimental results. Lattice QCD provides a from-first-principles approach to calculate form factors, and the challenge here is to control the statistical and systematic uncertainties as errors grow when going to higher Q2 values. Here we report on a calculation that tests the method using an ηs meson, a 'heavy pion' made of strange quarks, and also present preliminary results for kaon and pion form factors. We use the nf = 2 + 1 + 1 ensembles made by the MILC collaboration and Highly Improved Staggered Quarks, which allows us to obtain high statistics. The HISQ action is also designed to have small dicretisation errors. Using several light quark masses and lattice spacings allows us to control the chiral and continuum extrapolation and keep systematic errors in check. Warning, no authors found for 2018EPJWC.17506016.

  17. Optimal sensitivity for molecular recognition MAC-mode AFM

    PubMed

    Schindler; Badt; Hinterdorfer; Kienberger; Raab; Wielert-Badt; Pastushenko

    2000-02-01

    Molecular recognition force microscopy (MRFM) using the magnetic AC mode (MAC mode) atomic force microscope (AFM) was recently investigated to locate and probe recognition sites. A flexible crosslinker carrying a ligand is bound to the tip for the molecular recognition of receptors on the surface of a sample. In this report, the driving frequency is calculated which optimizes the sensitivity (S). The sensitivity of MRFM is defined as the relative change of the magnetically excited cantilever deflection amplitude arising from a crosslinker/antibody/antigen connection that is characterized by a very small force constant. The sensitivity is calculated in a damped oscillator model with a certain value of quality factor Q, which, together with load, defines the frequency response (unloaded oscillator shows resonance at Q > 0.707). If Q < 1, the greatest value of S corresponds to zero driving frequency omega (measured in units of eigenfrequency). Therefore, for Q < 1, MAC-mode has no advantage in comparison with DC-mode. Two additional extremes are found at omegaL = (1 - 1/Q)(1/2) and omegaR = (1 + 1/Q)(1/2), with corresponding sensitivities S(L) = Q2/(2Q - 1), S(R) = Q2/(2Q + 1). The L-extreme exists only for Q > 1, and then S(L) > S(R), i.e. the L-extreme is the main one. For Q > 1, S(L) > 1, and for Q > 2.41, S(R) > 1. These are the critical Q-values, above which selecting driving frequency equal to sigmaL or sigmaR brings advantage to MAC mode vs. DC mode. Satisfactory quality of the oscillator model is demonstrated by comparison of some results with those calculated within the classical description of cantilevers.

  18. Q estimation of seismic data using the generalized S-transform

    NASA Astrophysics Data System (ADS)

    Hao, Yaju; Wen, Xiaotao; Zhang, Bo; He, Zhenhua; Zhang, Rui; Zhang, Jinming

    2016-12-01

    Quality factor, Q, is a parameter that characterizes the energy dissipation during seismic wave propagation. The reservoir pore is one of the main factors that affect the value of Q. Especially, when pore space is filled with oil or gas, the rock usually exhibits a relative low Q value. Such a low Q value has been used as a direct hydrocarbon indicator by many researchers. The conventional Q estimation method based on spectral ratio suffers from the problem of waveform tuning; hence, many researchers have introduced time-frequency analysis techniques to tackle this problem. Unfortunately, the window functions adopted in time-frequency analysis algorithms such as continuous wavelet transform (CWT) and S-transform (ST) contaminate the amplitude spectra because the seismic signal is multiplied by the window functions during time-frequency decomposition. The basic assumption of the spectral ratio method is that there is a linear relationship between natural logarithmic spectral ratio and frequency. However, this assumption does not hold if we take the influence of window functions into consideration. In this paper, we first employ a recently developed two-parameter generalized S-transform (GST) to obtain the time-frequency spectra of seismic traces. We then deduce the non-linear relationship between natural logarithmic spectral ratio and frequency. Finally, we obtain a linear relationship between natural logarithmic spectral ratio and a newly defined parameter γ by ignoring the negligible second order term. The gradient of this linear relationship is 1/Q. Here, the parameter γ is a function of frequency and source wavelet. Numerical examples for VSP and post-stack reflection data confirm that our algorithm is capable of yielding accurate results. The Q-value results estimated from field data acquired in western China show reasonable comparison with oil-producing well location.

  19. Factor VII R353Q genetic polymorphism is associated with altered warfarin sensitivity among CYP2C9 *1/*1 carriers.

    PubMed

    Mlynarsky, Liat; Bejarano-Achache, Idit; Muszkat, Mordechai; Caraco, Yoseph

    2012-05-01

    Warfarin responsiveness is characterized by marked interindividual variability. A major portion of this variability is attributed to CYP2C9 and VKORC1 polymorphisms, but almost 50% is still unaccounted for. This paper reports the first prospective study on the association between factor VII R353Q polymorphism and warfarin responsiveness during induction. Genotyping for factor VII R353Q and 323D/I polymorphisms was performed in a cohort consisting of 374 patients (198 CYP2C9*1/*1) treated with warfarin who were prospectively followed from warfarin initiation. Compared with *1/*1-R/R and *1/*1-R/Q genotype carriers, *1/*1-Q/Q homozygotes achieved higher International Normalized Ratio (INR) values while consuming lower warfarin doses. The greater sensitivity was illustrated by 82.1% higher Warfarin Sensitivity Index During Induction (WSIDI) (0.14 ± 0.11 vs. 0.08 ± 0.50 mg⁻¹ Mann-Whitney, P = 0.043). Multiple regression analysis consisting of both genetic and nongenetic factors explained 26% of WSIDI variability, with R353Q genetic polymorphism having a modest yet significant effect and accounting for 1.7% of the overall variability. Moreover, the incidence of overanticoagulation (i.e., INR > 4) was 6.94-fold higher among *1/*1-Q/Q vs. *1/*1-R/R&R/Q carriers during warfarin induction (Pearson chi-square, P = 0.005). These findings were not accounted for by a chance difference in the distribution of VKORC1 genotypes. Analysis of these parameters among the entire cohort, including CYP2C9*2 and CYP2C9*3 variant allele carriers, did not reach statistical significance. Warfarin responsiveness during induction was unrelated to factor VII 323D/I genetic polymorphism. The response to warfarin during induction is influenced by factor VII R353Q polymorphism. The prospective use of this polymorphism, along with CYP2C9 and VKORC1, may enhance the accuracy of warfarin loading. However, the impact of R353Q polymorphism on overall warfarin response is subtle, and it is therefore unlikely that its use would be of clinical importance.

  20. Microspherical photonics: Sorting resonant photonic atoms by using light

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maslov, Alexey V., E-mail: avmaslov@yandex.ru; Astratov, Vasily N., E-mail: astratov@uncc.edu

    2014-09-22

    A method of sorting microspheres by resonant light forces in vacuum, air, or liquid is proposed. Based on a two-dimensional model, it is shown that the sorting can be realized by allowing spherical particles to traverse a focused beam. Under resonance with the whispering gallery modes, the particles acquire significant velocity along the beam direction. This opens a unique way of large-volume sorting of nearly identical photonic atoms with 1/Q accuracy, where Q is the resonance quality factor. This is an enabling technology for developing super-low-loss coupled-cavity structures and devices.

  1. The types and characteristics of clients' perceptions of the Bonny method of Guided Imagery and Music.

    PubMed

    Choi, Byungchuel; Lee, Nan Bok

    2014-01-01

    Developed by Helen Bonny, Guided Imagery and Music (BMGIM) has mainly been used to assist people with mental health issues. In order to provide clients with the most effective therapy, we need to examine the BMGIM process from the clients' perspective, rather than the therapists.' Understanding the types and characteristics of clients' experiences within the BMGIM process would be helpful to therapists. In order to assess clients' experiences more objectively, a different research methodology is needed to measure and compare the perspectives of clients in the BMGIM process. The purpose of this study was to identify the types and characteristics of perceptions in clients with mental health problems of the BMGIM experience. Q methodology was used to characterize client BMGIM perceptions. Scores from Q samples were coded into Q sample scores in order to calculate Q sort collected from a P sample of 20 participants. Participants were involved in the Q sorting as Q sorters and P sample. Q factor analysis was conducted using the QUANL program. The types and characteristics of the participants' perceptions were analyzed for three segments of the BMGIM session. From a factor analysis, (a) two factors were identified in the before music experience segment, (b) three factors in the during music experience segment, and (c) three factors in the after music experience segment. Factors that intervened in the therapeutic process of BMGIM were obtained from participants' direct GIM experiences. The knowledge of the types and characteristics of participants' perceptions of the GIM process will help therapists deliver more effective therapeutic interventions. Q methodology may also contribute to gaining a better understanding of BMGIM process. © the American Music Therapy Association 2014. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  2. Development and validation testing of a short nutrition questionnaire to identify dietary risk factors in preschoolers aged 12–36 months

    PubMed Central

    Rice, Niamh; Gibbons, Helena; McNulty, Breige A.; Walton, Janette; Flynn, Albert; Gibney, Michael J.; Nugent, Anne P.

    2015-01-01

    Background Although imbalances in dietary intakes can have short and longer term influences on the health of preschool children, few tools exist to quickly and easily identify nutritional risk in otherwise healthy young children. Objectives To develop and test the validity of a parent-administered questionnaire (NutricheQ) as a means of evaluating dietary risk in young children (12–36 months). Design Following a comprehensive development process and internal reliability assessment, the NutricheQ questionnaire was validated in a cohort of 371 Irish preschool children as part of the National Preschool Nutrition Survey. Dietary risk was rated on a scale ranging from 0 to 22 from 11 questions, with a higher score indicating higher risk. Results Children with higher NutricheQ scores had significantly (p<0.05) lower mean daily intakes of key nutrients such as iron, zinc, vitamin D, riboflavin, niacin, folate, phosphorous, potassium, carotene, retinol, and dietary fibre. They also had lower (p<0.05) intakes of vegetables, fish and fish dishes, meat and infant/toddler milks and higher intakes of processed foods and non-milk beverages, confectionery, sugars and savoury snack foods indicative of poorer dietary quality. Areas under the curve values of 84.7 and 75.6% were achieved for ‘medium’ and ‘high’ dietary risk when compared with expert risk ratings indicating good consistency between the two methods. Conclusion NutricheQ is a valid method of quickly assessing dietary quality in preschoolers and in identifying those at increased nutritional risk. In Context Analysis of data from national food and nutrition surveys typically identifies shortfalls in dietary intakes or quality of young children. This can relate to intakes of micronutrients such as iron or vitamin D as well as to the balance of macronutrients they consume (e.g. fat or sugar). Alongside this lie concerns regarding overweight and obesity and physical inactivity. This combination of risk factors has potential negative effects for both short and longer term health. Hence, screening tools, such as NutricheQ described here, offer an opportunity for early identification and subsequent appropriate timely intervention from 12 months of age. This paper describes the development and validation of NutricheQ, a short user-friendly questionnaire. Designed to be administered by parents or carers, it aims to help healthcare professionals identify children at risk based on known, evidence-based nutritional risk factors. It is hoped in the longer term that this tool can be adapted for use globally and improve child health through early identification, which can be followed up by targeted, cost-effective interventions. PMID:26058751

  3. The Logarithmic Tail of Néel Walls

    NASA Astrophysics Data System (ADS)

    Melcher, Christof

    We study the multiscale problem of a parametrized planar 180° rotation of magnetization states in a thin ferromagnetic film. In an appropriate scaling and when the film thickness is comparable to the Bloch line width, the underlying variational principle has the form where the reduced stray-field operator Q approximates (-Δ)1/2 as the quality factor Q tends to zero. We show that the associated Néel wall profile u exhibits a very long logarithmic tail. The proof relies on limiting elliptic regularity methods on the basis of the associated Euler-Lagrange equation and symmetrization arguments on the basis of the variational principle. Finally we study the renormalized limit behavior as Q tends to zero.

  4. Internal friction of rocks and volatiles on the moon

    NASA Technical Reports Server (NTRS)

    Tittmann, B. R.; Housley, R. M.; Cirlin, E. H.

    1973-01-01

    Internal friction quality factors Q up to 2200 have been observed in a strongly outgassed terrestrial analog of lunar basalt. This was accomplished by successively cycling a bar shaped sample vibrating in its fundamental longitudinal mode at 15 kHz to higher and higher temperatures in a vacuum between 100 and 10 nanotorr. After each cycle, Q measured at room temperature in the vacuum was observed to decrease with time suggesting that gas reabsorption was taking place even at these low pressures. A study of the effect of exposing a sample to a variety of gases and vapors showed that of the volatiles most likely to be present in the lunar environment H2O was by far the most effective in lowering Q.

  5. The effects of three factor VII polymorphisms on factor VII coagulant levels in healthy Singaporean Chinese, Malay and Indian newborns.

    PubMed

    Quek, S C; Low, P S; Saha, N; Heng, C K

    2006-11-01

    Factor VII (FVII) is an independent risk factor for coronary artery disease. Three polymorphisms of the factor VII gene (F7) were studied in a group of healthy newborns comprising 561 Chinese, 398 Malays and 226 Asian Indians from Singapore. The allele frequencies of 3 polymorphisms (R353Q, Promoter 0/10bp Del/Ins and Intron 7) in the FVII gene were ascertained through genotyping by polymerase chain reaction and restriction digestion of amplified fragments. In Chinese the minor allele frequencies are Q: 0.04, Ins: 0.03, R7: 0.44; Malays, Q: 0.06, Ins: 0.10, R7: 0.41; and Indians, Q: 0.25, Ins: 0.23, R7: 0.43. Strong linkage disequilibrium (Delta > 0.7) is observed between the 0/10 bp and the R353Q sites in all ethnic groups. We conclude that: (i) the prevalence of the minor Q and Ins alleles of the R353Q and 0/10 bp polymorphisms are significantly higher in the Indian newborns than the Chinese and Malays; (ii) the Q allele is significantly associated (p = 0.01) with a lower plasma FVII coagulant level in the Indian and Malay neonates; and this polymorphism explains up to 3.8% of the variance in FVII coagulant levels; (iii) there is no significant difference in allele frequencies of the three polymorphisms between neonates with and without family histories of CAD.

  6. Androgen receptor polyglutamine expansion drives age-dependent quality control defects and muscle dysfunction.

    PubMed

    Nath, Samir R; Yu, Zhigang; Gipson, Theresa A; Marsh, Gregory B; Yoshidome, Eriko; Robins, Diane M; Todi, Sokol V; Housman, David E; Lieberman, Andrew P

    2018-05-29

    Skeletal muscle has emerged as a critical, disease-relevant target tissue in spinal and bulbar muscular atrophy, a degenerative disorder of the neuromuscular system caused by a CAG/polyglutamine (polyQ) expansion in the androgen receptor (AR) gene. Here, we used RNA-Seq to identify pathways that are disrupted in diseased muscle using AR113Q knock-in mice. This analysis unexpectedly identified significantly diminished expression of numerous ubiquitin-proteasome pathway genes in AR113Q muscle, encoding approximately 30% of proteasome subunits and 20% of E2 ubiquitin conjugases. These changes were age-, hormone- and glutamine length-dependent and arose due to a toxic gain-of-function conferred by the mutation. Moreover, altered gene expression was associated with decreased level of the proteasome transcription factor NRF1 and its activator DDI2 and resulted in diminished proteasome activity. Ubiquitinated ADRM1 was detected in AR113Q muscle, indicating the occurrence of stalled proteasomes in mutant mice. Finally, diminished expression of Drosophila orthologues of NRF1 or ADRM1 promoted the accumulation of polyQ AR protein and increased toxicity. Collectively, these data indicate that AR113Q muscle develops progressive proteasome dysfunction that leads to the impairment of quality control and the accumulation of polyQ AR protein, key features that contribute to the age-dependent onset and progression of this disorder.

  7. The dimensional structure of psychopathology in 22q11.2 Deletion Syndrome.

    PubMed

    Niarchou, Maria; Moore, Tyler M; Tang, Sunny X; Calkins, Monica E; McDonald-McGuinn, Donna M; Zackai, Elaine H; Emanuel, Beverly S; Gur, Ruben C; Gur, Raquel E

    2017-09-01

    22q11.2 Deletion Syndrome (22q11.2DS) is one of the strongest known genetic risk factors for developing schizophrenia. Individuals with 22q11.2DS have high rates of neurodevelopmental disorders in childhood, while in adulthood ∼25% develop schizophrenia. Similar to the general population, high rates of comorbidity are common in 22q11.2DS. Employing a dimensional approach where psychopathology is examined at the symptom-level as complementary to diagnostic categories in a population at such high genetic risk for schizophrenia can help gain a better understanding of how psychopathology is structured as well as its genetic underpinnings. This is the first study to examine the dimensional structure of a wide spectrum of psychopathology in the context of a homogeneous genetic etiology like 22q11.2DS. We evaluated 331 individuals with 22q11.2DS, mean age (SD) = 16.9(8.7); 51% males, who underwent prospective comprehensive phenotyping. We sought to replicate previous findings by examining a bi-factor model that derives a general factor of psychopathology in addition to more specific dimensions of psychopathology (i.e., internalizing, externalizing and thought disorder). Psychopathology in 22q11.2DS was divided into one 'general psychopathology' factor and four specific dimensions (i.e., 'anxiety', 'mood', 'ADHD' and 'psychosis'). The 'psychosis' symptoms loaded strongly on the 'general psychopathology' factor. The similarity of the symptom structure of psychopathology between 22q11.2DS and community and clinical populations without the deletion indicate that 22q11.2DS can provide a model to explore alternative approaches to our current nosology. Our findings add to a growing literature indicating the need to reorganize current diagnostic classification systems. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Effect of low temperature baking in nitrogen on the performance of a niobium superconducting radio frequency cavity

    DOE PAGES

    Dhakal, Pashupati; Chetri, Santosh; Balachandran, Shreyas; ...

    2018-03-08

    Here, we report the rf performance of a single-cell superconducting radiofrequency cavity after low temperature baking in a nitrogen environment. A significant increase in quality factor has been observed when the cavity was heat treated in the temperature range of 120-160 °C with a nitrogen partial pressure of ~25 mTorr. This increase in quality factor as well as the Q-rise phenomenon (anti-Q-slope) is similar to those previously obtained with high temperature nitrogen doping as well as titanium doping. In this study, a cavity N 2-treated at 120 °C and at 140 °C, showed no degradation in accelerating gradient, however themore » accelerating gradient was reduced by ~25% with a 160 °C N 2 treatment, compared to the baseline tests after electropolishing. Sample coupons treated in the same conditions as the cavity were analyzed by scanning electron microscope, x-ray photoelectron spectroscopy and secondary ion mass spectroscopy revealed a complex surface composition of Nb 2O 5, NbO and NbN (1-x)O x within the rf penetration depth. Furthermore, magnetization measurements showed no significant change on bulk superconducting properties.« less

  9. Effect of low temperature baking in nitrogen on the performance of a niobium superconducting radio frequency cavity

    NASA Astrophysics Data System (ADS)

    Dhakal, Pashupati; Chetri, Santosh; Balachandran, Shreyas; Lee, Peter J.; Ciovati, Gianluigi

    2018-03-01

    We report the rf performance of a single cell superconducting radiofrequency cavity after low temperature baking in a nitrogen environment. A significant increase in quality factor has been observed when the cavity was heat treated in the temperature range of 120 - 160 °C with a nitrogen partial pressure of ˜25 m Torr . This increase in quality factor as well as the Q -rise phenomenon (anti-Q -slope) is similar to those previously obtained with high temperature nitrogen doping as well as titanium doping. In this study, a cavity N2 -treated at 120 °C and at 140 °C showed no degradation in accelerating gradient, however the accelerating gradient was reduced by ˜25 % with a 160 °C N2 treatment, compared to the baseline tests after electropolishing. Sample coupons treated in the same conditions as the cavity were analyzed by scanning electron microscope, x-ray photoelectron spectroscopy and secondary ion mass spectroscopy revealed a complex surface composition of Nb2O5 , NbO and NbN(1 -x )Ox within the rf penetration depth. Furthermore, magnetization measurements showed no significant change on bulk superconducting properties.

  10. A reappraisal of seismic Q evaluated at Mt. Etna volcano. Receipt for the application to risk analysis

    NASA Astrophysics Data System (ADS)

    Del Pezzo, Edoardo; Bianco, Francesca; Giampiccolo, Elisabetta; Tusa, Giuseppina; Tuvé, Tiziana

    2015-01-01

    A new approach in dealing with seismic risk in the volcanic areas of Italy, by taking into account the possible occurrence of damaging pre- or syn-eruptive seismic events, is exciting the scientific interest and is actually the topic developed in several research projects funded by the European Community (e.g., UPStrat-MAFA, www.upstrat-mafa.ov.ingv.it/UPstrat/) and the Civil Defense Department of Italy. To achieve this goal, it is necessary to have a detailed knowledge of the local attenuation-distance relations. In the present paper, we make a survey of the estimates of the seismic quality factor of the medium reported in literature for the Etna area. In the framework of a similar paper published for the Campi Flegrei zone in Southern Italy, we first review the results on seismic attenuation already obtained for Etna and then apply a standard technique to separately measure intrinsic and scattering attenuation coefficients from passive seismic data recorded by the Etna seismological network. Indications are then given for the correct utilization of the attenuation parameters to obtain the best candidate quality factor Q to be used in this area for seismic risk purposes.

  11. Effect of low temperature baking in nitrogen on the performance of a niobium superconducting radio frequency cavity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dhakal, Pashupati; Chetri, Santosh; Balachandran, Shreyas

    Here, we report the rf performance of a single-cell superconducting radiofrequency cavity after low temperature baking in a nitrogen environment. A significant increase in quality factor has been observed when the cavity was heat treated in the temperature range of 120-160 °C with a nitrogen partial pressure of ~25 mTorr. This increase in quality factor as well as the Q-rise phenomenon (anti-Q-slope) is similar to those previously obtained with high temperature nitrogen doping as well as titanium doping. In this study, a cavity N 2-treated at 120 °C and at 140 °C, showed no degradation in accelerating gradient, however themore » accelerating gradient was reduced by ~25% with a 160 °C N 2 treatment, compared to the baseline tests after electropolishing. Sample coupons treated in the same conditions as the cavity were analyzed by scanning electron microscope, x-ray photoelectron spectroscopy and secondary ion mass spectroscopy revealed a complex surface composition of Nb 2O 5, NbO and NbN (1-x)O x within the rf penetration depth. Furthermore, magnetization measurements showed no significant change on bulk superconducting properties.« less

  12. Scattering images from autocorrelation functions of P-wave seismic velocity images: the case of Tenerife Island (Canary Islands, Spain)

    NASA Astrophysics Data System (ADS)

    García-Yeguas, A.; Sánchez-Alzola, A.; De Siena, L.; Prudencio, J.; Díaz-Moreno, A.; Ibáñez, J. M.

    2018-03-01

    We present a P-wave scattering image of the volcanic structures under Tenerife Island using the autocorrelation functions of P-wave vertical velocity fluctuations. We have applied a cluster analysis to total quality factor attenuation ( {Q}_t^{-1} ) and scattering quality factor attenuation ( {Q}_{PSc}^{-1} ) images to interpret the structures in terms of intrinsic and scattering attenuation variations on a 2D plane, corresponding to a depth of 2000 m, and check the robustness of the scattering imaging. The results show that scattering patterns are similar to total attenuation patterns in the south of the island. There are two main areas where patterns differ: at Cañadas-Teide-Pico Viejo Complex, high total attenuation and average-to-low scattering values are observed. We interpret the difference as induced by intrinsic attenuation. In the Santiago Ridge Zone (SRZ) region, high scattering values correspond to average total attenuation. In our interpretation, the anomaly is induced by an extended scatterer, geometrically related to the surficial traces of Garachico and El Chinyero historical eruptions and the area of highest seismic activity during the 2004-2008 seismic crises.

  13. Smooth and flat phase-locked Kerr frequency comb generation by higher order mode suppression

    PubMed Central

    Huang, S.-W.; Liu, H.; Yang, J.; Yu, M.; Kwong, D.-L.; Wong, C. W.

    2016-01-01

    High-Q microresonator is perceived as a promising platform for optical frequency comb generation, via dissipative soliton formation. In order to achieve a higher quality factor and obtain the necessary anomalous dispersion, multi-mode waveguides were previously implemented in Si3N4 microresonators. However, coupling between different transverse mode families in multi-mode waveguides results in periodic disruption of dispersion and quality factor, and consequently causes perturbation to dissipative soliton formation and amplitude modulation to the corresponding spectrum. Careful choice of pump wavelength to avoid the mode crossing region is thus critical in conventional Si3N4 microresonators. Here, we report a novel design of Si3N4 microresonator in which single-mode operation, high quality factor, and anomalous dispersion are attained simultaneously. The novel microresonator is consisted of uniform single-mode waveguides in the semi-circle region, to eliminate bending induced mode coupling, and adiabatically tapered waveguides in the straight region, to avoid excitation of higher order modes. The intrinsic quality factor of the microresonator reaches 1.36 × 106 while the group velocity dispersion remains to be anomalous at −50 fs2/mm. With this novel microresonator, we demonstrate that broadband phase-locked Kerr frequency combs with flat and smooth spectra can be generated by pumping at any resonances in the optical C-band. PMID:27181420

  14. Stability of Q-Factors across Two Data Collection Methods.

    ERIC Educational Resources Information Center

    Daniel, Larry G.

    The purpose of the present study was to determine how two different data collection techniques would affect the Q-factors derived from several factor analytic procedures. Faculty members (N=146) from seven middle schools responded to 61 items taken from an instrument designed to measure aspects of an idealized middle school culture; the instrument…

  15. The woman's birth experience---the effect of interpersonal relationships and continuity of care.

    PubMed

    Dahlberg, Unn; Aune, Ingvild

    2013-04-01

    the aim of the present study was to gain a deeper understanding of how relational continuity in the childbearing process may influence the woman's birth experience. RESEARCH DESIGN/SETTING: a Q-methodological approach was chosen, as it allows the researcher to systematically assess subjectivity. 23 women were invited to sort a sample of 48 statements regarding their subjective view of birth experience after having participated in a pilot project in Norway, where six midwifery students provided continuity of care to 58 women throughout the childbearing process. The sorting patterns were subsequently factor-analysed, using the statistical software 'PQ' which reveals one strong and one weaker factor. The consensus statements and the defining statements for the two factors were later interpreted. both factors seemed to represent experiences of psychological trust and a feeling of team work along with the midwifery student. Both factors indicated the importance of quality in the relation. Factor one represented experiences of presence and emotional support in the relationship. It also represented a feeling of personal growth for the women. Factor two was defined by experiences of predictability in the relation and process, as well as the feeling of interdependency in the relation. According to quality in the relation, women defining factor two experienced that the content, not only the continuity in the relation, was important for the birth experience. relational continuity is a key concept in the context of a positive birth experience. Quality in the relation gives the woman a possibility to experience positivity during the childbearing process. Continuity in care and personal growth related to birth promote empowerment for both the woman and her partner. Relational continuity gives an opportunity for midwives to provide care in a more holistic manner. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. The effect of Q factor on gross mechanical efficiency and muscular activation in cycling.

    PubMed

    Disley, B X; Li, F-X

    2014-02-01

    Unexplored in scientific literature, Q Factor describes the horizontal width between bicycle pedals and determines where the foot is laterally positioned throughout the pedal stroke. The aim of the study was to determine whether changing Q Factor has a beneficial effect upon cycling efficiency and muscular activation. A total of 24 trained cyclists (11 men, 13 women; VO2max 57.5 ml·kg/min ± 6.1) pedaled at 60% of peak power output for 5 min at 90 rpm using Q Factors of 90, 120, 150, and 180 mm. Power output and gas were collected and muscular activity of the gastrocnemius medialis (GM), tibialis anterior (TA), vastus medialis (VM), and vastus lateralis (VL) measured using surface electromyography. There was a significant increase (P < 0.006) in gross mechanical efficiency (GME) for 90 and 120 mm (both 19.38%) compared with 150 and 180 mm (19.09% and 19.05%), representing an increase in external mechanical work performed of approximately 4-5 W (1.5-2.0%) at submaximal power outputs. There was no significant difference in the level of activity or timing of activation of the GM, TA, VM, and VL between Q Factors. Other muscles used in cycling, and possibly an improved application of force during the pedal stroke may play a role in the observed increase in GME with narrower Q Factors. © 2012 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Expediting evidence synthesis for healthcare decision-making: exploring attitudes and perceptions towards rapid reviews using Q methodology

    PubMed Central

    Moher, David; Clifford, Tammy J.

    2016-01-01

    Background Rapid reviews expedite the knowledge synthesis process with the goal of providing timely information to healthcare decision-makers who want to use evidence-informed policy and practice approaches. A range of opinions and viewpoints on rapid reviews is thought to exist; however, no research to date has formally captured these views. This paper aims to explore evidence producer and knowledge user attitudes and perceptions towards rapid reviews. Methods A Q methodology study was conducted to identify central viewpoints about rapid reviews based on a broad topic discourse. Participants rank-ordered 50 text statements and explained their Q-sort in free-text comments. Individual Q-sorts were analysed using Q-Assessor (statistical method: factor analysis with varimax rotation). Factors, or salient viewpoints on rapid reviews, were identified, interpreted and described. Results Analysis of the 11 individual Q sorts identified three prominent viewpoints: Factor A cautions against the use of study design labels to make judgements. Factor B maintains that rapid reviews should be the exception and not the rule. Factor C focuses on the practical needs of the end-user over the review process. Conclusion Results show that there are opposing viewpoints on rapid reviews, yet some unity exists. The three factors described offer insight into how and why various stakeholders act as they do and what issues may need to be resolved before increase uptake of the evidence from rapid reviews can be realized in healthcare decision-making environments. PMID:27761324

  18. Investigations on LGS and LGT crystals to realize BAW resonators.

    PubMed

    Imbaud, Joël; Boy, Jean-Jacques; Galliou, Serge; Bourquin, Roger; Romand, Jean Pierre

    2008-11-01

    The LGS family are promising materials for the design of high quality bulk acoustic wave resonators. We have manufactured many plano-convex 10 MHz 5th overtone Y-cut resonators using langasite (LGS, La(3)Ga(5)SiO(14)) and langatate (LGT, La(3)Ga(5.5)Ta(0.5)O(14)) crystals. We observed that the quality factor strongly depends on the polishing method, the supplier of the material, and on the energy trapping. For quartz crystals, we have found that resulting IR spectra exhibit absorption peaks more or less deep, linked to defects. These predominant criteria are not surprising, but they have to be defined in manner similar to that used for quartz crystal. A satisfying machining and polishing method has been first applied to elaborate high Q resonators, and a comparison between samples of LGS and LGT materials from different suppliers is established. In addition, LGT resonators are characterized by their motional parameters and frequency-temperature curves. Nevertheless, one of the main results is that the measured Q x f product is not the expected one. We present results of Q-factor versus radius of curvature: it appears that an optimization should be performed and that this last one cannot be directly transposed from that of quartz crystal resonator. Currently, the best resonator that we have made has a Q x f product of 1.4 x 10(13) on its 5th overtone (1.7 x 10(13) on its 9th overtone). This result is slightly higher than the similar parameter obtained on a state-of-the-art SC-cut quartz crystal resonator working at the same frequency.

  19. Lateral and depth variations of coda Q in the Zagros region of Iran

    NASA Astrophysics Data System (ADS)

    Irandoust, Mohsen Ahmadzadeh; Sobouti, Farhad; Rahimi, Habib

    2016-01-01

    We have analyzed more than 2800 local earthquakes recorded by the Iranian National Seismic Network (INSN) and the Iranian Seismological Center (IRSC) to estimate coda wave quality factor, Q c , in the Zagros fold and thrust belt and the Sanandaj-Sirjan metamorphic zone in Iran. We used the single backscattering model to investigate lateral and depth variations of Q c in the study region. In the interior of Zagros, no strong lateral variation in attenuation parameters is observed. In SE Zagros (the Bandar-Abbas region) where transition to the Makran subduction setting begins, the medium shows lower attenuation. The average frequency relations for the SSZ, the Bandar-Abbas region, and the Zagros are Q c = (124 ± 11) f 0.82 ± 0.04, Q c = (109 ± 2) f 0.99 ± 0.01, and Q c = (85 ± 5) f 1.06 ± 0.03, respectively. To investigate the depth variation of Q c , 18 time windows between 5 and 90 s and at two epicentral distance ranges of R < 100 km and 100 < R < 200 km were considered. It was observed that with increasing coda lapse time, Q 0 ( Q c at 1 Hz) and n (frequency dependence factor) show increasing and decreasing trends, respectively. Beneath the SSZ and at depths of about 50 to 80 km, there is a correlation between the reported low velocity medium and the observed sharp change in the trend of Q 0 and n curves. In comparison with results obtained in other regions of the Iranian plateau, the Zagros along with the Alborz Mountains in the north show highest attenuation of coda wave and strongest frequency dependence, an observation that reflects the intense seismicity and active faulting in these mountain ranges. We also observe a stronger depth dependence of attenuation in the Zagros and SSZ compared to central Iran, indicating a thicker lithosphere in the Zagros region than in central Iran.

  20. Regulation of the yjjQ-bglJ Operon, Encoding LuxR-Type Transcription Factors, and the Divergent yjjP Gene by H-NS and LeuO▿ †

    PubMed Central

    Stratmann, Thomas; Madhusudan, S.; Schnetz, Karin

    2008-01-01

    The yjjQ and bglJ genes encode LuxR-type transcription factors conserved in several enterobacterial species. YjjQ is a potential virulence factor in avian pathogenic Escherichia coli. BglJ counteracts the silencing of the bgl (β-glucoside) operon by H-NS in E. coli K-12. Here we show that yjjQ and bglJ form an operon carried by E. coli K-12, whose expression is repressed by the histone-like nucleoid structuring (H-NS) protein. The LysR-type transcription factor LeuO counteracts this repression. Furthermore, the yjjP gene, encoding a membrane protein of unknown function and located upstream in divergent orientation to the yjjQ-bglJ operon, is likewise repressed by H-NS. Mapping of the promoters as well as the H-NS and LeuO binding sites within the 555-bp intergenic region revealed that H-NS binds to the center of the AT-rich regulatory region and distal to the divergent promoters. LeuO sites map to the center and to positions distal to the yjjQ promoters, while one LeuO binding site overlaps with the divergent yjjP promoter. This latter LeuO site is required for full derepression of the yjjQ promoters. The arrangement of regulatory sites suggests that LeuO restructures the nucleoprotein complex formed by H-NS. Furthermore, the data support the conclusion that LeuO, whose expression is likewise repressed by H-NS and which is a virulence factor in Salmonella enterica, is a master regulator that among other loci, also controls the yjjQ-bglJ operon and thus indirectly the presumptive targets of YjjQ and BglJ. PMID:18055596

  1. Fertility after uterine artery embolization for symptomatic multiple fibroids with no other infertility factors.

    PubMed

    Torre, Antoine; Fauconnier, Arnaud; Kahn, Vanessa; Limot, Olivier; Bussierres, Laurence; Pelage, Jean Pierre

    2017-07-01

    To evaluate the fertility of women eligible for surgical multiple myomectomy, but who carefully elected a fertility-sparing uterine artery embolization (UAE). Non-comparative open-label trial, on women ≤40 years, presenting with multiple symptomatic fibroids (at least 3, ≥3 cm), immediate pregnancy wish, and no associated infertility factor. Women had a bilateral limited UAE using tris-acryl gelatin microspheres ≥500 μm. Fertility, ovarian reserve, uterus and fibroid sizes, and quality of life questionnaires (UFS-QoL) were prospectively followed. Fifteen patients, aged 34.8 years (95%CI 32.2-37.5, median 36.0, q1-q3 29.4-39.5) were included from November 2008 to May 2012. During the year following UAE, 9 women actively attempting to conceive experienced 5 live-births (intention-to-treat fertility rate 33.3%, 95%CI 11.8%-61.6%). Markers of ovarian reserve remained stable. The symptoms score was reduced by 66% (95%CI 48%-85%) and the quality of life score was improved by 112% (95%CI 21%-204%). Uterine volume was reduced by 38% (95%CI 24%-52%). Women were followed for 43.1 months (95%CI 32.4-53.9), 10 live-births occurred in 8 patients, and 5 patients required secondary surgeries for fibroids. Women without associated infertility factors demonstrated an encouraging capacity to deliver after UAE. Further randomized controlled trials comparing UAE and myomectomy are warranted. • Women without infertility factors showed an encouraging delivery rate after UAE. • For women choosing UAE over abdominal myomectomy, childbearing may not be impaired. • Data are insufficient to definitively recommend UAE as comparable to myomectomy. • Further randomized trials comparing fertility after UAE or myomectomy are warranted.

  2. Formaldehyde substitute fixatives: effects on nucleic acid preservation.

    PubMed

    Moelans, Cathy B; Oostenrijk, Daphne; Moons, Michiel J; van Diest, Paul J

    2011-11-01

    In surgical pathology, formalin-fixed paraffin-embedded tissues are increasingly being used as a source of DNA and RNA for molecular assays in addition to histopathological evaluation. However, the commonly used formalin fixative is carcinogenic, and its crosslinking impairs DNA and RNA quality. The suitability of three new presumably less toxic, crosslinking (F-Solv) and non-crosslinking (FineFIX, RCL2) alcohol-based fixatives was tested for routine molecular pathology in comparison with neutral buffered formalin (NBF) as gold standard. Size ladder PCR, epidermal growth factor receptor sequence analysis, microsatellite instability (MSI), chromogenic (CISH), fluorescence in situ hybridisation (FISH) and qPCR were performed. The alcohol-based non-crosslinking fixatives (FineFIX and RCL2) resulted in a higher DNA yield and quality compared with crosslinking fixatives (NBF and F-Solv). Size ladder PCR resulted in a shorter amplicon size (300 bp) for both crosslinking fixatives compared with the non-crosslinking fixatives (400 bp). All four fixatives were directly applicable for MSI and epidermal growth factor receptor sequence analysis. All fixatives except F-Solv showed clear signals in CISH and FISH. RNA yield and quality were superior after non-crosslinking fixation. qPCR resulted in lower Ct values for RCL2 and FineFIX. The alcohol-based non-crosslinking fixatives performed better than crosslinking fixatives with regard to DNA and RNA yield, quality and applicability in molecular diagnostics. Given the higher yield, less starting material may be necessary, thereby increasing the applicability of biopsies for molecular studies.

  3. Multi-stage phononic crystal structure for anchor-loss reduction of thin-film piezoelectric-on-silicon microelectromechanical-system resonator

    NASA Astrophysics Data System (ADS)

    Bao, Fei-Hong; Bao, Lei-Lei; Li, Xin-Yi; Ammar Khan, Muhammad; Wu, Hua-Ye; Qin, Feng; Zhang, Ting; Zhang, Yi; Bao, Jing-Fu; Zhang, Xiao-Sheng

    2018-06-01

    Thin-film piezoelectric-on-silicon acoustic wave resonators are promising for the development of system-on-chip integrated circuits with micro/nano-engineered timing reference. However, in order to realize their large potentials, a further enhancement of the quality factor (Q) is required. In this study, a novel approach, based on a multi-stage phononic crystal (PnC) structure, was proposed to achieve an ultra-high Q. A systematical study revealed that the multi-stage PnC structure formed a frequency-selective band-gap to effectively prohibit the dissipation of acoustic waves through tethers, which significantly reduced the anchor loss, leading to an insertion-loss reduction and enhancement of Q. The maximum unloaded Q u of the fabricated resonators reached the value of ∼10,000 at 109.85 MHz, indicating an enhancement by 19.4 times.

  4. On charged particle equilibrium violation in external photon fields.

    PubMed

    Bouchard, Hugo; Seuntjens, Jan; Palmans, Hugo

    2012-03-01

    In a recent paper by Bouchard et al. [Med. Phys. 36(10), 4654-4663 (2009)], a theoretical model of quality correction factors for idealistic so-called plan-class specific reference (PCSR) fields was proposed. The reasoning was founded on the definition of PCSR fields made earlier by Alfonso et al. [Med. Phys. 35(11), 5179-5186 (2008)], requiring the beam to achieve charged particle equilibrium (CPE), in a time-averaged sense, in the reference medium. The relation obtained by Bouchard et al. was derived using Fano's theorem (1954) which states that if CPE is established in a given medium, the dose is independent of point-to-point density variations. A potential misconception on the achievability of the condition required by Fano (1954) might be responsible for false practical conclusions, both in the definition of PCSR fields as well as the theoretical model of quality correction factor. In this paper, the practical achievability of CPE in external beams is treated in detail. The fact that this condition is not achievable in single or composite deliveries is illustrated by an intuitive method and is also formally demonstrated. Fano's theorem is not applicable in external beam radiation dosimetry without (virtually) removing attenuation effects, and therefore, the relation conditionally defined by Bouchard et al. (2009) cannot be valid in practice. A definition of PCSR fields in the recent formalism for nonstandard beams proposed by Alfonso et al. (2008) should be modified, revising the criterion of CPE condition. The authors propose reconsidering the terminology used to describe standard and nonstandard beams. The authors argue that quality correction factors of intensity modulated radiation therapy PCSR fields (i.e., k(Q(pcsr),Q) (f(pcsr),f(ref) )) could be unity under ideal conditions, but it is concluded that further investigation is necessary to confirm that hypothesis.

  5. T wave abnormalities, high body mass index, current smoking and high lipoprotein (a) levels predict the development of major abnormal Q/QS patterns 20 years later. A population-based study

    PubMed Central

    Moller, Christina Strom; Byberg, Liisa; Sundstrom, Johan; Lind, Lars

    2006-01-01

    Background Most studies on risk factors for development of coronary heart disease (CHD) have been based on the clinical outcome of CHD. Our aim was to identify factors that could predict the development of ECG markers of CHD, such as abnormal Q/QS patterns, ST segment depression and T wave abnormalities, in 70-year-old men, irrespective of clinical outcome. Methods Predictors for development of different ECG abnormalities were identified in a population-based study using stepwise logistic regression. Anthropometrical and metabolic factors, ECG abnormalities and vital signs from a health survey of men at age 50 were related to ECG abnormalities identified in the same cohort 20 years later. Results At the age of 70, 9% had developed a major abnormal Q/QS pattern, but 63% of these subjects had not been previously hospitalized due to MI, while 57% with symptomatic MI between age 50 and 70 had no major Q/QS pattern at age 70. T wave abnormalities (Odds ratio 3.11, 95% CI 1.18–8.17), high lipoprotein (a) levels, high body mass index (BMI) and smoking were identified as significant independent predictors for the development of abnormal major Q/QS patterns. T wave abnormalities and high fasting glucose levels were significant independent predictors for the development of ST segment depression without abnormal Q/QS pattern. Conclusion T wave abnormalities on resting ECG should be given special attention and correlated with clinical information. Risk factors for major Q/QS patterns need not be the same as traditional risk factors for clinically recognized CHD. High lipoprotein (a) levels may be a stronger risk factor for silent myocardial infarction (MI) compared to clinically recognized MI. PMID:16519804

  6. Polymorphisms of the factor VII gene associated with the low activities of vitamin K-dependent coagulation factors in one-month-old infants.

    PubMed

    Ito, Koichi; Goto, Kenji; Sugiura, Tokio; Muramatsu, Kanji; Ando, Toshihiro; Maniwa, Hiroko; Yokoyama, Takao; Sugiyama, Kohachiro; Togari, Hajime

    2007-01-01

    Despite administration of vitamin K (VK), some infants show lower activity of VK-dependent coagulation factors and they could develop intracranial hemorrhage. For preventing VK deficiency bleeding (VKDB) in infants, oral administration of VK and a screening test for VK deficiency are carried out in Japan. For the screening, the total activity of VK-dependent coagulation factors is measured using a commercial product, Normotest. This study was undertaken to clarify the importance of the following genetic and environmental factors on the coagulation status in one-month-old infants: two polymorphisms in the factor VII gene, -323P0/10 (a 10-bp insertion in the promoter region at position -323) and R353Q (the replacement of arginine [R] with glutamine [Q] at residue 353) and sex, age, gestational age, birth weight, and feeding regimen. Two hundred Japanese infants (34.6 +/- 4.0 days old) were screened for VK-dependent coagulation activity with Normotest and were genotyped for the two polymorphisms. Among the subjects screened, 18 infants (9%) carried the P10 allele and 26 (13%) carried the R353Q allele. Multiple regression analysis showed that the 10-bp inserted (P10) allele or the Q allele was associated with the lower coagulation activities. The coagulation activities for the R/Q genotype were significantly lower than those for the R/R genotype and those for the P0/P10 genotype were significantly lower than those for the P0/P0 genotype. Therefore, infants who carry the P10 allele or the Q allele show lower activity of VK-dependent coagulation factors. These infants may have a higher risk of VKDB manifestation.

  7. Q factor of megahertz LC circuits based on thin films of YBaCuO high-temperature superconductor

    NASA Astrophysics Data System (ADS)

    Masterov, D. V.; Pavlov, S. A.; Parafin, A. E.

    2008-05-01

    High-frequency properties of resonant structures based on thin films of YBa2Cu3O7 δ high-temperature superconductor are studied experimentally in the frequency range 30 100 MHz. The structures planar induction coils with a self-capacitance fabricated on neodymium gallate and lanthanum aluminate substrates. The unloaded Q factor of the circuits exceeds 2 × 105 at 77 K and 40 MHz. Possible loss mechanisms that determine the Q factor of the superconducting resonant structures in the megahertz range are considered.

  8. A pipeline design of a fast prime factor DFT on a finite field

    NASA Technical Reports Server (NTRS)

    Truong, T. K.; Hsu, In-Shek; Shao, H. M.; Reed, Irving S.; Shyu, Hsuen-Chyun

    1988-01-01

    A conventional prime factor discrete Fourier transform (DFT) algorithm is used to realize a discrete Fourier-like transform on the finite field, GF(q sub n). This algorithm is developed to compute cyclic convolutions of complex numbers and to decode Reed-Solomon codes. Such a pipeline fast prime factor DFT algorithm over GF(q sub n) is regular, simple, expandable, and naturally suitable for VLSI implementation. An example illustrating the pipeline aspect of a 30-point transform over GF(q sub n) is presented.

  9. The Effect of Specimen Size on the Results of Concrete Adiabatic Temperature Rise Test with Commercially Available Equipment.

    PubMed

    Lee, Byung Jae; Bang, Jin Wook; Shin, Kyung Joon; Kim, Yun Yong

    2014-12-08

    In this study, adiabatic temperature rise tests depending on binder type and adiabatic specimen volume were performed, and the maximum adiabatic temperature rises and the reaction factors for each mix proportion were analyzed and suggested. The results indicated that the early strength low heat blended cement mixture had the lowest maximum adiabatic temperature rise ( Q ∞ ) and the ternary blended cement mixture had the lowest reaction factor ( r ). Also, Q and r varied depending on the adiabatic specimen volume even when the tests were conducted with a calorimeter, which satisfies the recommendations for adiabatic conditions. Test results show a correlation: the measurements from the 50 L specimens were consistently higher than those from the 6 L specimens. However, the Q ∞ and r values of the 30 L specimen were similar to those of the 50 L specimen. Based on the above correlation, the adiabatic temperature rise of the 50 L specimen could be predicted using the results of the 6 L and 30 L specimens. Therefore, it is thought that this correlation can be used for on-site concrete quality control and basic research.

  10. An investigation of constructions of justice and injustice in chronic pain: a Q-methodology approach.

    PubMed

    McParland, Joanna; Hezseltine, Louisa; Serpell, Michael; Eccleston, Christopher; Stenner, Paul

    2011-09-01

    This study used Q-methodology to explore justice-related accounts of chronic pain. Eighty participants completed the Q-sorting procedure (33 chronic pain sufferers and 47 non-pain sufferers). Analysis revealed five main factors. Three factors blame: society for poor medical and interpersonal treatment; the chronic pain sufferer for indulging in self-pity and unempathic healthcare workers for ignoring patients. A fourth factor acknowledges the unfairness of pain and encourages self-reliance. The fifth factor rejects injustice in the chronic pain discourse. Overall, there is a shared view that chronic pain brings unfair treatment, disrespect and a de-legitimization of pain. Future research ideas are suggested.

  11. Thermoelastic Damping in Cone Microcantilever Resonator

    NASA Astrophysics Data System (ADS)

    Li, Pu; Zhou, Hongyue

    2017-07-01

    Microbeams with continuous or discontinuous variable cross-section have been applied in Microelectromechanical Systems (MEMS) resonators, such as tapered microbeam, torsion microbeam and stepped microbeam. Thermoelastic damping (TED), which is verified as a fundamental energy lost mechanism for microresonators, is calculated by the Zener’s model and Lifshits and Roukes’s (LR) model in general. However, for non-uniform microbeam resonators, these two classical models are not suitable in some cases. On the basis of Zener’s theory, a TED model for cone microcantilever with rectangular cross-section has been derived in this study. The comparison of results obtained by the present model and Finite Element Method (FEM) model proves that the proposed model is able to predict TED value for cone microcantilever. In addition, TED in cone microcantilever is nearly same as TED in wedge microcantilever. The results show that quality factors (Q-factors) of cone microcantilever and wedge microcantilever are larger than Q-factor of uniform microbeam at low frequencies. The Debye peak value of a uniform microcantilever is equal to 0.5Δ E , while those of cone microcantilever and wedge microcantilever are about 0.438ΔE and 0.428ΔE, respectively.

  12. Impact of substrate etching on plasmonic elements and metamaterials: preventing red shift and improving refractive index sensitivity.

    PubMed

    Moritake, Yuto; Tanaka, Takuo

    2018-02-05

    We propose and demonstrate the elimination of substrate influence on plasmon resonance by using selective and isotropic etching of substrates. Preventing the red shift of the resonance due to substrates and improving refractive index sensitivity were experimentally demonstrated by using plasmonic nanostructures fabricated on silicon substrates. Applying substrate etching decreases the effective refractive index around the metal nanostructures, resulting in elimination of the red shift. Improvement of sensitivity to the refractive index environment was demonstrated by using plasmonic metamaterials with Fano resonance based on far field interference. Change in quality factors (Q-factors) of the Fano resonance by substrate etching was also investigated in detail. The presence of a closely positioned substrate distorts the electric field distribution and degrades the Q-factors. Substrate etching dramatically increased the refractive index sensitivity reaching to 1532 nm/RIU since the electric fields under the nanostructures became accessible through substrate etching. The FOM was improved compared to the case without the substrate etching. The method presented in this paper is applicable to a variety of plasmonic structures to eliminate the influence of substrates for realizing high performance plasmonic devices.

  13. Nucleon form factors from quenched lattice QCD with domain wall fermions

    NASA Astrophysics Data System (ADS)

    Sasaki, Shoichi; Yamazaki, Takeshi

    2008-07-01

    We present a quenched lattice calculation of the weak nucleon form factors: vector [FV(q2)], induced tensor [FT(q2)], axial vector [FA(q2)] and induced pseudoscalar [FP(q2)] form factors. Our simulations are performed on three different lattice sizes L3×T=243×32, 163×32, and 123×32 with a lattice cutoff of a-1≈1.3GeV and light quark masses down to about 1/4 the strange quark mass (mπ≈390MeV) using a combination of the DBW2 gauge action and domain wall fermions. The physical volume of our largest lattice is about (3.6fm)3, where the finite volume effects on form factors become negligible and the lower momentum transfers (q2≈0.1GeV2) are accessible. The q2 dependences of form factors in the low q2 region are examined. It is found that the vector, induced tensor, and axial-vector form factors are well described by the dipole form, while the induced pseudoscalar form factor is consistent with pion-pole dominance. We obtain the ratio of axial to vector coupling gA/gV=FA(0)/FV(0)=1.219(38) and the pseudoscalar coupling gP=mμFP(0.88mμ2)=8.15(54), where the errors are statistical errors only. These values agree with experimental values from neutron β decay and muon capture on the proton. However, the root mean-squared radii of the vector, induced tensor, and axial vector underestimate the known experimental values by about 20%. We also calculate the pseudoscalar nucleon matrix element in order to verify the axial Ward-Takahashi identity in terms of the nucleon matrix elements, which may be called as the generalized Goldberger-Treiman relation.

  14. Constructions of sex and intimacy after cancer: Q methodology study of people with cancer, their partners, and health professionals

    PubMed Central

    2013-01-01

    Background The increasing number of individuals living with cancer has led to a focus on the quality of life of survivors, and their families. Sexual wellbeing is a central component of quality of life, with a growing body of research demonstrating the association between cancer and changes to sexuality and intimacy. However, little is known about patient and professional understanding of cancer and sexuality post-cancer. This study was designed to explore the complex perspectives that people with personal and professional experience with cancer hold about sexuality in the context of cancer. Methods An interview study using Q methodology was conducted with 44 people with cancer, 35 partners of a person with cancer and 37 health professionals working in oncology. Participants were asked to rank-order 56 statements about sexuality and intimacy after cancer and asked to comment on their rankings in a subsequent semi-structured interview. A by-person factor analysis was performed with factors extracted according to the centroid method with a varimax rotation. Results A three-factor solution provided the best conceptual fit for the perspectives regarding intimacy and sexuality post-cancer. Factor 1, entitled “communication – dispelling myths about sex and intimacy” positions communication as central to the acceptance of a range of satisfying sexual and intimate practices post-cancer. Factor 2, “valuing sexuality across the cancer journey,” centres on the theme of normalizing the experience of sex after cancer through the renegotiation of sex and intimacy: the development of alternative sexual practices. Factor 3, “intimacy beyond sex,” presents the view that even though sex may not be wanted, desired, or even possible following cancer, quality of life and relationship satisfaction are achieved through communication and non-genital intimacy. Conclusions This study has demonstrated the complexity of perspectives about sexuality and intimacy post cancer, which has practical implications for those working in cancer care and survivorship. Therapists and other health professionals can play an important role in ameliorating concerns surrounding sexual wellbeing after cancer, by opening and facilitating discussion of sexuality and intimacy amongst couples affected by cancer, as well as providing information that normalizes a range of sexual and intimate practices. PMID:23725590

  15. Reactive Oxygen Species-Inducible ECF σ Factors of Bradyrhizobium japonicum

    PubMed Central

    Masloboeva, Nadezda; Reutimann, Luzia; Stiefel, Philipp; Follador, Rainer; Leimer, Nadja; Hennecke, Hauke; Mesa, Socorro; Fischer, Hans-Martin

    2012-01-01

    Extracytoplasmic function (ECF) σ factors control the transcription of genes involved in different cellular functions, such as stress responses, metal homeostasis, virulence-related traits, and cell envelope structure. The genome of Bradyrhizobium japonicum, the nitrogen-fixing soybean endosymbiont, encodes 17 putative ECF σ factors belonging to nine different ECF σ factor families. The genes for two of them, ecfQ (bll1028) and ecfF (blr3038), are highly induced in response to the reactive oxygen species hydrogen peroxide (H2O2) and singlet oxygen (1O2). The ecfF gene is followed by the predicted anti-σ factor gene osrA (blr3039). Mutants lacking EcfQ, EcfF plus OsrA, OsrA alone, or both σ factors plus OsrA were phenotypically characterized. While the symbiotic properties of all mutants were indistinguishable from the wild type, they showed increased sensitivity to singlet oxygen under free-living conditions. Possible target genes of EcfQ and EcfF were determined by microarray analyses, and candidate genes were compared with the H2O2-responsive regulon. These experiments disclosed that the two σ factors control rather small and, for the most part, distinct sets of genes, with about half of the genes representing 13% of the members of H2O2-responsive regulon. To get more insight into transcriptional regulation of both σ factors, the 5′ ends of ecfQ and ecfF mRNA were determined. The presence of conserved sequence motifs in the promoter region of ecfQ and genes encoding EcfQ-like σ factors in related α-proteobacteria suggests regulation via a yet unknown transcription factor. By contrast, we have evidence that ecfF is autoregulated by transcription from an EcfF-dependent consensus promoter, and its product is negatively regulated via protein-protein interaction with OsrA. Conserved cysteine residues 129 and 179 of OsrA are required for normal function of OsrA. Cysteine 179 is essential for release of EcfF from an EcfF-OsrA complex upon H2O2 stress while cysteine 129 is possibly needed for EcfF-OsrA interaction. PMID:22916258

  16. High-Q/V Monolithic Diamond Microdisks Fabricated with Quasi-isotropic Etching.

    PubMed

    Khanaliloo, Behzad; Mitchell, Matthew; Hryciw, Aaron C; Barclay, Paul E

    2015-08-12

    Optical microcavities enhance light-matter interactions and are essential for many experiments in solid state quantum optics, optomechanics, and nonlinear optics. Single crystal diamond microcavities are particularly sought after for applications involving diamond quantum emitters, such as nitrogen vacancy centers, and for experiments that benefit from diamond's excellent optical and mechanical properties. Light-matter coupling rates in experiments involving microcavities typically scale with Q/V, where Q and V are the microcavity quality-factor and mode-volume, respectively. Here we demonstrate that microdisk whispering gallery mode cavities with high Q/V can be fabricated directly from bulk single crystal diamond. By using a quasi-isotropic oxygen plasma to etch along diamond crystal planes and undercut passivated diamond structures, we create monolithic diamond microdisks. Fiber taper based measurements show that these devices support TE- and TM-like optical modes with Q > 1.1 × 10(5) and V < 11(λ/n) (3) at a wavelength of 1.5 μm.

  17. Characteristic analysis of a polarization output coupling Porro prism resonator

    NASA Astrophysics Data System (ADS)

    Yang, Hailong; Meng, Junqing; Chen, Weibiao

    2015-02-01

    An Electro-optical Q-switched Nd:YAG slab laser with a crossed misalignment Porro prism resonator for space applications has been theoretically and experimentally investigated. The phase shift induced by the combination of different wave plates and Porro prism azimuth angles have been studied for creating high loss condition prior to Q-switching. The relationship of the effective output coupling reflectivity and the employed Q-switch driving voltage is explored by using Jones matrix optics. In the experiment, the maximum output pulse energy of 93 mJ with 14-ns pulse duration is obtained at the repetition rate of 20 Hz and the optical-to-optical conversion efficiency is 16.8%. The beam quality factors are M 2 x = 2.5 and M 2y = 2.2, respectively.

  18. JLab Measurements of the He 3 Form Factors at Large Momentum Transfers

    DOE PAGES

    Camsonne, A.; Katramatou, A. T.; Olson, M.; ...

    2017-10-19

    The charge and magnetic form factors, F C and F M, respectively, of 3He are extracted in the kinematic range 25 fm –2 ≤ Q 2 ≤ 61 fm –2 from elastic electron scattering by detecting 3He recoil nuclei and scattered electrons in coincidence with the two High Resolution Spectrometers of the Hall A Facility at Jefferson Lab. The measurements find evidence for the existence of a second diffraction minimum for the magnetic form factor at Q 2 = 49.3 fm –2 and for the charge form factor at Q 2 = 62.0 fm –2. Both minima are predicted tomore » exist in the Q 2 range accessible by this Jefferson Lab experiment. Here, the data are in qualitative agreement with theoretical calculations based on realistic interactions and accurate methods to solve the three-body nuclear problem.« less

  19. JLab Measurements of the He 3 Form Factors at Large Momentum Transfers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Camsonne, A.; Katramatou, A. T.; Olson, M.

    The charge and magnetic form factors, F C and F M, respectively, of 3He are extracted in the kinematic range 25 fm –2 ≤ Q 2 ≤ 61 fm –2 from elastic electron scattering by detecting 3He recoil nuclei and scattered electrons in coincidence with the two High Resolution Spectrometers of the Hall A Facility at Jefferson Lab. The measurements find evidence for the existence of a second diffraction minimum for the magnetic form factor at Q 2 = 49.3 fm –2 and for the charge form factor at Q 2 = 62.0 fm –2. Both minima are predicted tomore » exist in the Q 2 range accessible by this Jefferson Lab experiment. Here, the data are in qualitative agreement with theoretical calculations based on realistic interactions and accurate methods to solve the three-body nuclear problem.« less

  20. Post-Outbreak Investigation of Pseudomonas aeruginosa Faucet Contamination by Quantitative Polymerase Chain Reaction and Environmental Factors Affecting Positivity.

    PubMed

    Bédard, Emilie; Laferrière, Céline; Charron, Dominique; Lalancette, Cindy; Renaud, Christian; Desmarais, Nadia; Déziel, Eric; Prévost, Michèle

    2015-11-01

    To perform a post-outbreak prospective study of the Pseudomonas aeruginosa contamination at the faucets (water, aerator and drain) by culture and quantitative polymerase chain reaction (qPCR) and to assess environmental factors influencing occurrence A 450-bed pediatric university hospital in Montreal, Canada Water, aerator swab, and drain swab samples were collected from faucets and analyzed by culture and qPCR for the post-outbreak investigation. Water microbial and physicochemical parameters were measured, and a detailed characterization of the sink environmental and design parameters was performed. The outbreak genotyping investigation identified drains and aerators as the source of infection. The implementation of corrective measures was effective, but post-outbreak sampling using qPCR revealed 50% positivity for P. aeruginosa remaining in the water compared with 7% by culture. P. aeruginosa was recovered in the water, the aerator, and the drain in 21% of sinks. Drain alignment vs the faucet and water microbial quality were significant factors associated with water positivity, whereas P. aeruginosa load in the water was an average of 2 log higher for faucets with a positive aerator. P. aeruginosa contamination in various components of sink environments was still detected several years after the resolution of an outbreak in a pediatric university hospital. Although contamination is often not detectable in water samples by culture, P. aeruginosa is present and can recover its culturability under favorable conditions. The importance of having clear maintenance protocols for water systems, including the drainage components, is highlighted.

  1. Dual Q-switched laser outputs from a single lasing medium using an intracavity MEMS micromirror array.

    PubMed

    Bauer, Ralf; Lubeigt, Walter; Uttamchandani, Deepak

    2012-09-01

    An intracavity array of individually controlled microelectromechanical system scanning micromirrors was used to actively Q-switch a single side-pumped Nd:YAG gain medium. Two equal power independent laser outputs were simultaneously obtained by separate actuation of two adjacent micromirrors with a combined average output power of 125 mW. Pulse durations of 28 ns FWHM at 8.7 kHz repetition frequency and 34 ns FWHM at 7.9 kHz repetition frequency were observed for the two output beams with beam quality factors M2 of 1.2 and 1.1 and peak powers of 253 W and 232 W, respectively.

  2. Aluminum nitride integrated photonics platform for the ultraviolet to visible spectrum.

    PubMed

    Lu, Tsung-Ju; Fanto, Michael; Choi, Hyeongrak; Thomas, Paul; Steidle, Jeffrey; Mouradian, Sara; Kong, Wei; Zhu, Di; Moon, Hyowon; Berggren, Karl; Kim, Jeehwan; Soltani, Mohammad; Preble, Stefan; Englund, Dirk

    2018-04-30

    We demonstrate a wide-bandgap semiconductor photonics platform based on nanocrystalline aluminum nitride (AlN) on sapphire. This photonics platform guides light at low loss from the ultraviolet (UV) to the visible spectrum. We measure ring resonators with intrinsic quality factor (Q) exceeding 170,000 at 638 nm and Q >20,000 down to 369.5 nm, which shows a promising path for low-loss integrated photonics in UV and visible spectrum. This platform opens up new possibilities in integrated quantum optics with trapped ions or atom-like color centers in solids, as well as classical applications including nonlinear optics and on-chip UV-spectroscopy.

  3. Sparsity-optimized separation of body waves and ground-roll by constructing dictionaries using tunable Q-factor wavelet transforms with different Q-factors

    NASA Astrophysics Data System (ADS)

    Chen, Xin; Chen, Wenchao; Wang, Xiaokai; Wang, Wei

    2017-10-01

    Low-frequency oscillatory ground-roll is regarded as one of the main regular interference waves, which obscures primary reflections in land seismic data. Suppressing the ground-roll can reasonably improve the signal-to-noise ratio of seismic data. Conventional suppression methods, such as high-pass and various f-k filtering, usually cause waveform distortions and loss of body wave information because of their simple cut-off operation. In this study, a sparsity-optimized separation of body waves and ground-roll, which is based on morphological component analysis theory, is realized by constructing dictionaries using tunable Q-factor wavelet transforms with different Q-factors. Our separation model is grounded on the fact that the input seismic data are composed of low-oscillatory body waves and high-oscillatory ground-roll. Two different waveform dictionaries using a low Q-factor and a high Q-factor, respectively, are confirmed as able to sparsely represent each component based on their diverse morphologies. Thus, seismic data including body waves and ground-roll can be nonlinearly decomposed into low-oscillatory and high-oscillatory components. This is a new noise attenuation approach according to the oscillatory behaviour of the signal rather than the scale or frequency. We illustrate the method using both synthetic and field shot data. Compared with results from conventional high-pass and f-k filtering, the results of the proposed method prove this method to be effective and advantageous in preserving the waveform and bandwidth of reflections.

  4. Motivation for orthodontic treatment investigated with Q-methodology: patients' and parents' perspectives.

    PubMed

    Prabakaran, Rema; Seymour, Shiri; Moles, David R; Cunningham, Susan J

    2012-08-01

    Motivation and cooperation are vital components of orthodontic treatment if a good outcome is to be achieved. In this study, we used Q-methodology to investigate motivating factors among adolescents seeking orthodontic treatment and parents wanting their children to undergo orthodontic treatment. This technique asks participants to rank a series of statements, and the analysis of this ranking then provides insight into the participants' opinions. Each of these complementary studies was divided into 2 phases: interviews to generate a list of reasons for seeking orthodontic treatment and the use of Q-methodology to assess and categorize the relative importance of these reasons for the groups of participants. In the patient study, 32 items were generated from the interviews and placed in order of importance on a Q-methodology grid by 60 patients who were about to commence orthodontic treatment. The rankings were subjected to factor analysis, which categorized the patients' views into groups of shared opinions. The same methodology was used with the parent group, and a Q-methodology grid was designed to accommodate 35 items that were then ranked by the 60 parents. The rankings were subjected to factor analysis as for the patient group. For the patients, factor analysis identified 3 factors, all of which included esthetics, as important. The remaining respondents had more individual viewpoints and did not map to any of the 3 factors. For the parents, factor analysis identified 4 factors, all of which included treatment in adolescence to prevent future problems, as important. This study showed that Q-methodology is a novel and efficient tool that can be used in dental research with few difficulties. It might prove useful for the aspects of care for which subjective views or opinions play an important role. Copyright © 2012 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  5. High beam quality of a Q-switched 2-µm Tm,Ho:LuVO4 laser

    NASA Astrophysics Data System (ADS)

    Wang, Wei; Yang, Xining; Shen, Yingjie; Li, Linjun; Zhou, Long; Yang, Yuqiang; Bai, Yunfeng; Xie, Wenqiang; Ye, Guangchao; Yu, Xiaoyang

    2018-05-01

    A diode-end-pumped 2.05-µm Q-switched Tm,Ho:LuVO4 laser is reported in this paper. The cryogenic Tm3+ (5.0 at.%),Ho3+ (0.5 at.%):LuVO4 crystal was pumped by an 800-nm laser diode. At a pulse repetition frequency of 10 kHz, the maximum average output power of 3.77 W was achieved at 77 K when an incident pump power of 14.7 W was used. The slope efficiency and optical-optical conversion efficiency were 28.3 and 25.6%, respectively. The maximum per pulse energy was 2.54 mJ for a pulse duration of 69.9 ns. The beam quality factor Mx 2 was approximately 1.17 and My 2 was approximately 1.01 for the Tm,Ho:LuVO4 laser.

  6. Relationship and variation of qPCR and culturable enterococci estimates in ambient surface waters are predictable

    USGS Publications Warehouse

    Whitman, Richard L.; Ge, Zhongfu; Nevers, Meredith B.; Boehm, Alexandria B.; Chern, Eunice C.; Haugland, Richard A.; Lukasik, Ashley M.; Molina, Marirosa; Przybyla-Kelly, Kasia; Shively, Dawn A.; White, Emily M.; Zepp, Richard G.; Byappanahalli, Muruleedhara N.

    2010-01-01

    The quantitative polymerase chain reaction (qPCR) method provides rapid estimates of fecal indicator bacteria densities that have been indicated to be useful in the assessment of water quality. Primarily because this method provides faster results than standard culture-based methods, the U.S. Environmental Protection Agency is currently considering its use as a basis for revised ambient water quality criteria. In anticipation of this possibility, we sought to examine the relationship between qPCR-based and culture-based estimates of enterococci in surface waters. Using data from several research groups, we compared enterococci estimates by the two methods in water samples collected from 37 sites across the United States. A consistent linear pattern in the relationship between cell equivalents (CCE), based on the qPCR method, and colony-forming units (CFU), based on the traditional culturable method, was significant (P 10CFU > 2.0/100 mL) while uncertainty increases at lower CFU values. It was further noted that the relative error in replicated qPCR estimates was generally higher than that in replicated culture counts even at relatively high target levels, suggesting a greater need for replicated analyses in the qPCR method to reduce relative error. Further studies evaluating the relationship between culture and qPCR should take into account analytical uncertainty as well as potential differences in results of these methods that may arise from sample variability, different sources of pollution, and environmental factors.

  7. Association of neighborhood-level factors with hospitalization for community-associated methicillin-resistant Staphylococcus aureus, New York City, 2006: a multilevel observational study.

    PubMed

    Farr, Amanda M; Marx, Melissa A; Weiss, Don; Nash, Denis

    2013-02-13

    Hospitalizations with community-associated methicillin-resistant Staphylococcus aureus (CA-MRSA) infection have increased in New York City, with substantial geographic variation across neighborhoods. While individual-level risk factors, such as age, sex, HIV infection, and diabetes have been described, the role of neighborhood-level factors (e.g., neighborhood HIV prevalence or income) has not been examined. To explore plausible neighborhood-level factors associated with CA-MRSA-related hospitalizations, a retrospective analysis was conducted using New York City hospital discharges from 2006 and New York City-specific survey and health department surveillance data. CA-MRSA-related hospitalizations were identified using diagnosis codes and admission information. Associations were determined by using sex-specific multilevel logistic regression. The CA-MRSA hospitalization rate varied by more than six-fold across New York City neighborhoods. Females hospitalized with CA-MRSA had more than twice the odds of residing in neighborhoods in the highest quintile of HIV prevalence (adjusted odds ratio [AOR](Q5 vs. Q1) 2.3, 95% CI: 1.2, 2.7). Both males and females hospitalized with CA-MRSA had nearly twice the odds of residing in neighborhoods with moderately high proportion of men who have sex with men (MSM) residing in the neighborhood (males: AOR(Q4 vs. Q1) 1.7, 95% CI: 1.1, 2.7; females: AOR(Q4 vs. Q1) 2.0, 95% CI: 1.1, 3.6); but this association did not hold for neighborhoods in the highest quintile (males: AOR(Q5 vs. Q1) 1.2, 95% CI: 0.76, 1.8; females: AOR(Q5 vs. Q1) 1.5, 95% CI: 0.82, 2.7). Neighborhood-level characteristics were associated with CA-MRSA hospitalization odds, independent of individual-level risk factors, and may contribute to the population-level burden of CA-MRSA infection.

  8. Is the coexistence of sustained ST-segment elevation and abnormal Q waves a risk factor for electrical storm in implanted cardioverter defibrillator patients with structural heart diseases?

    PubMed

    Furushima, Hiroshi; Chinushi, Masaomi; Iijima, Kenichi; Hasegawa, Kanae; Sato, Akinori; Izumi, Daisuke; Watanabe, Hiroshi; Aizawa, Yoshifusa

    2012-05-01

    The aim of this study was to determine whether or not the coexistence of sustained ST-segment elevation and abnormal Q waves (STe-Q) could be a risk factor for electrical storm (ES) in implanted cardioverter defibrillator (ICD) patients with structural heart diseases. In all, 156 consecutive patients received ICD therapy for secondary prevention of sudden cardiac death and/or sustained ventricular tachyarrhythmias were included. Electrical storm was defined as ≥3 separate episodes of ventricular tachycardia (VT) and/or ventricular fibrillation (VF) terminated by ICD therapies within 24 h. During a mean follow-up of 1825 ± 1188 days, 42 (26.9%) patients experienced ES, of whom 12 had coronary artery disease, 15 had idiopathic dilated cardiomyopathy, 6 had hypertrophic cardiomyopathy, 4 had arrhythmogenic right ventricular cardiomyopathy, 4 had cardiac sarcoidosis, and 1 had valvular heart disease. Sustained ST-segment elevation and abnormal Q waves in ≥2 leads on the 12-lead electrocardiography was observed in 33 (21%) patients. On the Kaplan-Meier analysis, patients with STe-Q had a markedly higher risk of ES than those without STe-Q (P< 0.0001). The multivariate Cox proportional hazards regression model indicated that STe-Q and left ventricular ejection fraction (LVEF) (<30%) were independent risk factors associated with the recurrence of VT/VF (STe-Q: HR 1.962, 95% CI 1.24-3.12, P= 0.004; LVEF: HR 1.860, 95% CI 1.20-2.89, P= 0.006), and STe-Q was an independent risk factor associated with ES (HR 4.955, 95% CI 2.69-9.13, P< 0.0001). Sustained ST-segment elevation and abnormal Q waves could be a risk factor of not only recurrent VT/VF but also ES in patients with structural heart diseases.

  9. Ultracompact low-threshold organic laser.

    PubMed

    Deotare, Parag B; Mahony, Thomas S; Bulović, Vladimir

    2014-11-25

    We report an ultracompact low-threshold laser with an Alq3:DCM host:guest molecular organic thin film gain layer. The device uses a photonic crystal nanobeam cavity which provides a high quality factor to mode volume (Q/V) ratio and increased spontaneous emission factor along with a small footprint. Lasing is observed with a threshold of 4.2 μJ/cm(2) when pumped by femtosecond pulses of λ = 400 nm wavelength light. We also model the dynamics of the laser and show good agreement with the experimental data. The inherent waveguide geometry of the structure enables easy on-chip integration with potential applications in biochemical sensing, inertial sensors, and data communication.

  10. Psychometric evaluation of Persian Nomophobia Questionnaire: Differential item functioning and measurement invariance across gender.

    PubMed

    Lin, Chung-Ying; Griffiths, Mark D; Pakpour, Amir H

    2018-03-01

    Background and aims Research examining problematic mobile phone use has increased markedly over the past 5 years and has been related to "no mobile phone phobia" (so-called nomophobia). The 20-item Nomophobia Questionnaire (NMP-Q) is the only instrument that assesses nomophobia with an underlying theoretical structure and robust psychometric testing. This study aimed to confirm the construct validity of the Persian NMP-Q using Rasch and confirmatory factor analysis (CFA) models. Methods After ensuring the linguistic validity, Rasch models were used to examine the unidimensionality of each Persian NMP-Q factor among 3,216 Iranian adolescents and CFAs were used to confirm its four-factor structure. Differential item functioning (DIF) and multigroup CFA were used to examine whether males and females interpreted the NMP-Q similarly, including item content and NMP-Q structure. Results Each factor was unidimensional according to the Rach findings, and the four-factor structure was supported by CFA. Two items did not quite fit the Rasch models (Item 14: "I would be nervous because I could not know if someone had tried to get a hold of me;" Item 9: "If I could not check my smartphone for a while, I would feel a desire to check it"). No DIF items were found across gender and measurement invariance was supported in multigroup CFA across gender. Conclusions Due to the satisfactory psychometric properties, it is concluded that the Persian NMP-Q can be used to assess nomophobia among adolescents. Moreover, NMP-Q users may compare its scores between genders in the knowledge that there are no score differences contributed by different understandings of NMP-Q items.

  11. A Steel Ball Surface Quality Inspection Method Based on a Circumferential Eddy Current Array Sensor.

    PubMed

    Zhang, Huayu; Xie, Fengqin; Cao, Maoyong; Zhong, Mingming

    2017-07-01

    To efficiently inspect surface defects on steel ball bearings, a new method based on a circumferential eddy current array (CECA) sensor was proposed here. The best probe configuration, in terms of the coil quality factor (Q-factor), magnetic field intensity, and induced eddy current density on the surface of a sample steel ball, was determined using 3-, 4-, 5-, and 6-coil probes, for analysis and comparison. The optimal lift-off from the measured steel ball, the number of probe coils, and the frequency of excitation current suitable for steel ball inspection were obtained. Using the resulting CECA sensor to inspect 46,126 steel balls showed a miss rate of ~0.02%. The sensor was inspected for surface defects as small as 0.05 mm in width and 0.1 mm in depth.

  12. Infiltrated photonic crystal cavity as a highly sensitive platform for glucose concentration detection

    NASA Astrophysics Data System (ADS)

    Arafa, Safia; Bouchemat, Mohamed; Bouchemat, Touraya; Benmerkhi, Ahlem; Hocini, Abdesselam

    2017-02-01

    A Bio-sensing platform based on an infiltrated photonic crystal ring shaped holes cavity-coupled waveguide system is proposed for glucose concentration detection. Considering silicon-on-insulator (SOI) technology, it has been demonstrated that the ring shaped holes configuration provides an excellent optical confinement within the cavity region, which further enhances the light-matter interactions at the precise location of the analyte medium. Thus, the sensitivity and the quality factor (Q) can be significantly improved. The transmission characteristics of light in the biosensor under different refractive indices that correspond to the change in the analyte glucose concentration are analyzed by performing finite-difference time-domain (FDTD) simulations. Accordingly, an improved sensitivity of 462 nm/RIU and a Q factor as high as 1.11х105 have been achieved, resulting in a detection limit of 3.03х10-6 RIU. Such combination of attributes makes the designed structure a promising element for performing label-free biosensing in medical diagnosis and environmental monitoring.

  13. Biosensing Using Microring Resonator Interferograms

    PubMed Central

    Hsu, Shih-Hsiang; Yang, Yung-Chia; Su, Yu-Hou; Wang, Sheng-Min; Huang, Shih-An; Lin, Ching-Yu

    2014-01-01

    Optical low-coherence interferometry (OLCI) takes advantage of the variation in refractive index in silicon-wire microring resonator (MRR) effective lengths to perform glucose biosensing using MRR interferograms. The MRR quality factor (Q), proportional to the effective length, could be improved using the silicon-wire propagation loss and coupling ratio from the MRR coupler. Our study showed that multimode interference (MMI) performed well in broad band response, but the splitting ratio drifted to 75/25 due to the stress issue. The glucose sensing sensitivity demonstrated 0.00279 meter per refractive-index-unit (RIU) with a Q factor of ∼30,000 under transverse electric polarization. The 1,310 nm DFB laser was built in the OLCI system as the optical ruler achieving 655 nm characterization accuracy. The lowest sensing limitation was therefore 2 × 10−4 RIU. Moreover, the MRR effective length from the glucose sensitivity could be utilized to experimentally demonstrate the silicon wire effective refractive index with a width of 0.45 μm and height of 0.26 μm. PMID:24434876

  14. Simplex-method based transmission performance optimization for 100G PDM-QPSK systems with non-identical spans

    NASA Astrophysics Data System (ADS)

    Li, Yuanyuan; Gao, Guanjun; Zhang, Jie; Zhang, Kai; Chen, Sai; Yu, Xiaosong; Gu, Wanyi

    2015-06-01

    A simplex-method based optimizing (SMO) strategy is proposed to improve the transmission performance for dispersion uncompensated (DU) coherent optical systems with non-identical spans. Through analytical expression of quality of transmission (QoT), this strategy improves the Q factors effectively, while minimizing the number of erbium-doped optical fiber amplifier (EDFA) that needs to be optimized. Numerical simulations are performed for 100 Gb/s polarization-division multiplexed quadrature phase shift keying (PDM-QPSK) channels over 10-span standard single mode fiber (SSMF) with randomly distributed span-lengths. Compared to the EDFA configurations with complete span loss compensation, the Q factor of the SMO strategy is improved by approximately 1 dB at the optimal transmitter launch power. Moreover, instead of adjusting the gains of all the EDFAs to their optimal value, the number of EDFA that needs to be adjusted for SMO is reduced from 8 to 2, showing much less tuning costs and almost negligible performance degradation.

  15. Super-narrow, extremely high quality collective plasmon resonances at telecom wavelengths and their application in a hybrid graphene-plasmonic modulator.

    PubMed

    Thackray, Benjamin D; Thomas, Philip A; Auton, Gregory H; Rodriguez, Francisco J; Marshall, Owen P; Kravets, Vasyl G; Grigorenko, Alexander N

    2015-05-13

    We present extremely narrow collective plasmon resonances observed in gold nanostripe arrays fabricated on a thin gold film, with the spectral line full width at half-maximum (fwhm) as low as 5 nm and quality factors Q reaching 300, at important fiber-optic telecommunication wavelengths around 1.5 μm. Using these resonances, we demonstrate a hybrid graphene-plasmonic modulator with the modulation depth of 20% in reflection operated by gating of a single layer graphene, the largest measured so far.

  16. On the output factor measurements of the CyberKnife iris collimator small fields: Experimental determination of the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors for microchamber and diode detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pantelis, E.; Moutsatsos, A.; Zourari, K.

    Purpose: To measure the output factors (OFs) of the small fields formed by the variable aperture collimator system (iris) of a CyberKnife (CK) robotic radiosurgery system, and determine the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors for a microchamber and four diode detectors. Methods: OF measurements were performed using a PTW PinPoint 31014 microchamber, four diode detectors (PTW-60017, -60012, -60008, and the SunNuclear EDGE detector), TLD-100 microcubes, alanine dosimeters, EBT films, and polymer gels for the 5 mm, 7.5 mm, 10 mm, 12.5 mm, and 15 mm irismore » collimators at 650 mm, 800 mm, and 1000 mm source to detector distance (SDD). The alanine OF measurements were corrected for volume averaging effects using the 3D dose distributions registered in polymer gel dosimeters. k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors for the PinPoint microchamber and the diode dosimeters were calculated through comparison against corresponding polymer gel, EBT, alanine, and TLD results. Results: Experimental OF results are presented for the array of dosimetric systems used. The PinPoint microchamber was found to underestimate small field OFs, and a k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factor ranging from 1.127 {+-} 0.022 (for the 5 mm iris collimator) to 1.004 {+-} 0.010 (for the 15 mm iris collimator) was determined at the reference SDD of 800 mm. The PinPoint k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factor was also found to increase with decreasing SDD; k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} values equal to 1.220 {+-} 0.028 and 1.077 {+-} 0.016 were obtained for the 5 mm iris collimator at 650 mm and 1000 mm SDD, respectively. On the contrary, diode detectors were found to overestimate small field OFs and a correction factor equal to 0.973 {+-} 0.006, 0.954 {+-} 0.006, 0.937 {+-} 0.007, and 0.964 {+-} 0.006 was measured for the PTW-60017, -60012, -60008 and the EDGE diode detectors, respectively, for the 5 mm iris collimator at 800 mm SDD. The corresponding correction factors for the 15 mm iris collimator were found equal to 0.997 {+-} 0.010, 0.994 {+-} 0.009, 0.988 {+-} 0.010, and 0.986 {+-} 0.010, respectively. No correlation of the diode k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors with SDD was observed. Conclusions: This work demonstrates an experimental procedure for the determination of the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors required to obtain small field OF results of increased accuracy.« less

  17. Head and neck cancer patients' experiences of percutaneous endoscopic gastrostomy feeding: a Q-methodology study.

    PubMed

    Merrick, S; Farrell, D

    2012-07-01

    Head and neck cancer patients are at high risk of malnutrition and its complications and therefore often undergo non-oral nasogastric or percutaneous endoscopic gastrostomy (PEG) nutrition support. However, there is little evidence that either approach is effective in this group. While one possible explanation for these findings relates to the relationship between artificial tube feeding and poor quality of life, there is little research that examines the patient's subjective experience of nutrition support. This study investigated the experiences of PEG tube feeding in head and neck cancer patients undergoing radical treatment. Conventional Q-methodology was used with 15 head and neck cancer patients, who rank-ordered 36 statements according to the extent to which these reflected their experiences of PEG tube feeding. The sorted statements were factor-analysed case-wise to provide clusters of similar experiences. Three perspectives emerged. Factor 1, labelled 'Constructive cognitive appraisal', focused around positive adaptation to, and acceptance of, PEG feeding. Factor 2, labelled 'Cognitive-affective dissonance', reflected ambivalence between cognitive acceptance and affective rejection of the PEG tube. Factor 3, labelled 'Emotion-focused appraisal', was characterised by tube-focused anxiety and fear. The findings broadly confirm Levanthal et al.'s Self-Regulatory Model of coping and support the need for genuine and individualised patient-centred nutritional care. © 2012 Blackwell Publishing Ltd.

  18. High-Q whispering-gallery mode sensor in liquids

    NASA Astrophysics Data System (ADS)

    Nadeau, Jay L.; Ilchenko, Vladimir S.; Kossakovski, Dmitri; Bearman, Gregory H.; Maleki, Lute

    2002-06-01

    Optical sensing of biomolecules on microfabricated glass surfaces requires surface coatings that minimize nonspecific binding while preserving the optical properties of the sensor. Microspheres with whispering-gallery (WG) modes can achieve quality factor (Q) levels many orders of magnitude greater than those of other WG-based microsensors: greater than 1010 in air, and greater than 109 in a variety of solvents, including methanol, H2O and phosphate buffered saline (PBS). The presence of dyes that absorb in the wavelength of the WG excitation in the evanescent zone can cause this Q value to drop by almost 3 orders of magnitude. Silanization of the surface with mercapto-terminal silanes is compatible with high Q (>109), but chemical cross-linking of streptavidin reduces the Q to 105-106 due to build-up of a thick, irregular layer of protein. However, linkage of biotin to the silane terminus preserves the Q at a ~2x107 and yields a reactive surface sensitive to avidin-containing ligands in a concentration-dependent manner. Improvements in the reliability of the surface chemistry show promise for construction of an ultrasensitive biosensor.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wally Melnitchouk; John Tjon

    We compute the corrections from two-photon and \\gamma-Z exchange in parity-violating elastic electron--proton scattering, used to extract the strange form factors of the proton. We use a hadronic formalism that successfully reconciled the earlier discrepancy in the proton's electron to magnetic form factor ratio, suitably extended to the weak sector. Implementing realistic electroweak form factors, we find effects of the order 2-3% at Q^2 <~ 0.1 GeV^2, which are largest at backward angles, and have a strong Q^2 dependence at low Q^2. Two-boson contributions to the weak axial current are found to be enhanced at low Q^2 and for forwardmore » angles. We provide corrections at kinematics relevant for recent and upcoming parity-violating experiments.« less

  20. Relating transverse-momentum-dependent and collinear factorization theorems in a generalized formalism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Collins, J.; Gamberg, L.; Prokudin, A.

    We construct an improved implementation for combining TMD factorization transverse- momentum-dependent (TMD) factorization and collinear factorization. TMD factorization is suit- able for low transverse momentum physics, while collinear factorization is suitable for high transverse momenta and for a cross section integrated over transverse momentum. The result is a modified version of the standard W + Y prescription traditionally used in the Collins-Soper-Sterman (CSS) formalism and related approaches. As a result, we further argue that questions regarding the shape and Q- dependence of the cross sections at lower Q are largely governed by the matching to the Y -term.

  1. Relating transverse-momentum-dependent and collinear factorization theorems in a generalized formalism

    DOE PAGES

    Collins, J.; Gamberg, L.; Prokudin, A.; ...

    2016-08-08

    We construct an improved implementation for combining TMD factorization transverse- momentum-dependent (TMD) factorization and collinear factorization. TMD factorization is suit- able for low transverse momentum physics, while collinear factorization is suitable for high transverse momenta and for a cross section integrated over transverse momentum. The result is a modified version of the standard W + Y prescription traditionally used in the Collins-Soper-Sterman (CSS) formalism and related approaches. As a result, we further argue that questions regarding the shape and Q- dependence of the cross sections at lower Q are largely governed by the matching to the Y -term.

  2. Exploring obesogenic environments: the design and development of the migrant obesogenic perception of the environment questionnaire (MOPE-Q) using a sample of Iranian migrants in Australia.

    PubMed

    Delavari, Maryam; Sønderlund, Anders Larrabee; Mellor, David; Mohebbi, Mohammadreza; Swinburn, Boyd

    2014-06-06

    Although there are a number of studies examining the effect of migration on obesity, these studies tend to focus on the role of acculturation in this relationship. However, there are indications that the change in environment may also be an important factor. Indeed, there is a considerable lack of psychometric tools designed to assess the association between environment and migrant health behaviour. The current study aimed to assess the literature on the link between environment and health for migrants, and on the basis of this information, design and develop the Migrant Obesogenic Perception of the Environment questionnaire (MOPE-Q). The MOPE-Q is the first comprehensive measure of the impact of environmental factors on migrant health behaviour related to physical activity, food habits and body image concern, as well as weight change. Using a systematic approach, an initial pool of items for the questionnaire was developed and refined on the basis of rigorous content and face validity assessments and factor analysis. Further, reliability tests and test re-test studies were undertaken. Differences between Iranian and Australian environmental factors as they relate to obesogenic behaviour were explored using the developed measure. A total of 36 items were developed for the MOPE-Q. Principal factor analysis identified three similar factor structures of environmental factors related to obesity (categorized in terms of facilitators, barriers and pressures) for each country. The final questionnaire consisted of four distinct subscales pertaining specifically to the Australian environment and five subscales pertaining to the Iranian environment, accounting for 59% and 63%, respectively, of the total variance in obesity rates. Data suggests that the MOPE-Q is a reliable and valid self-report measure for assessing the relationship between environmental factors linked to obesity and obesogenic behaviour for this particular migrant group. The variations in environmental factors linked to obesity behaviour between home (Iran) and host (Australia) countries have been incorporated into the MOPE-Q instrument which has shown good psychometric properties. The MOPE-Q can be adapted and applied to other environments and populations to help explain changes in diet, physical activity patterns and body weight in migrant groups as they acculturate.

  3. Exploring end of life priorities in Saudi males: usefulness of Q-methodology.

    PubMed

    Hammami, Muhammad M; Al Gaai, Eman; Hammami, Safa; Attala, Sahar

    2015-11-26

    Quality end-of-life care depends on understanding patients' end-of-life choices. Individuals and cultures may hold end-of-life priorities at different hierarchy. Forced ranking rather than independent rating, and by-person factor analysis rather than averaging may reveal otherwise masked typologies. We explored Saudi males' forced-ranked, end-of-life priorities and dis-priorities. Respondents (n = 120) rank-ordered 47 opinion statements on end-of-life care following a 9-category symmetrical distribution. Statements' scores were analyzed by averaging analysis and factor analysis (Q-methodology). Respondents' mean age was 32.1 years (range, 18-65); 52% reported average religiosity, 88 and 83% ≥ very good health and life-quality, respectively, and 100% ≥ high school education. Averaging analysis revealed that the extreme five end-of-life priorities were to, be at peace with God, be able to say the statement of faith, maintain dignity, resolve conflicts, and have religious death rituals respected, respectively. The extreme five dis-priorities were to, die in the hospital, not receive intensive care if in coma, die at peak of life, be informed about impending death by family/friends rather than doctor, and keep medical status confidential from family/friends, respectively. Q-methodology classified 67% of respondents into five highly transcendent opinion types. Type-I (rituals-averse, family-caring, monitoring-coping, life-quality-concerned) and Type-V (rituals-apt, family-centered, neutral-coping, life-quantity-concerned) reported the lowest and highest religiosity, respectively. Type-II (rituals-apt, family-dependent, monitoring-coping, life-quantity-concerned) and Type-III (rituals-silent, self/family-neutral, avoidance-coping, life-quality & quantity-concerned) reported the best and worst life-quality, respectively. Type-I respondents were the oldest with the lowest general health, in contrast to Type-IV (rituals-apt, self-centered, monitoring-coping, life-quality/quantity-neutral). Of the extreme 14 priorities/dis-priorities for the five types, 29, 14, 14, 50, and 36%, respectively, were not among the extreme 20 priorities/dis-priorities identified by averaging analysis for the entire cohort. 1) Transcendence was the extreme end-of-life priority, and dying in the hospital was the extreme dis-priority. 2) Quality of life was conceptualized differently with less emphasize on its physiological aspects. 3) Disclosure of terminal illness to family/close friends was preferred as long it is through the patient. 4) Q-methodology identified five types of constellations of end-of-life priorities and dis-priorities that may be related to respondents' demographics and are partially masked by averaging analysis.

  4. High sensitivity and high Q-factor nanoslotted parallel quadrabeam photonic crystal cavity for real-time and label-free sensing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Daquan; State Key Laboratory of Information Photonics and Optical Communications, School of Information and Communication Engineering, Beijing University of Posts and Telecommunications, Beijing 100876; School of Engineering and Applied Sciences, Harvard University, Cambridge, Massachusetts 02138

    We experimentally demonstrate a label-free sensor based on nanoslotted parallel quadrabeam photonic crystal cavity (NPQC). The NPQC possesses both high sensitivity and high Q-factor. We achieved sensitivity (S) of 451 nm/refractive index unit and Q-factor >7000 in water at telecom wavelength range, featuring a sensor figure of merit >2000, an order of magnitude improvement over the previous photonic crystal sensors. In addition, we measured the streptavidin-biotin binding affinity and detected 10 ag/mL concentrated streptavidin in the phosphate buffered saline solution.

  5. Vector and Axial Form Factors Applied to Neutrino Quasielastic Scattering

    NASA Astrophysics Data System (ADS)

    Budd, H.; Bodek, A.; Arrington, J.

    2005-02-01

    We calculate the quasielastic cross sections for neutrino scattering on nucleons using up to date fits to the nucleon elastic electromagnetic form factors GEp, GEn, GMp, GMn, and weak form factors. We show the extraction of F(q). We show the that F(q) has a different contribution to the anti-neutrino cross section, and how the anti-neutrino data can be used to check F(q) extracted from neutrino scattering. (Presented by Howard Budd at NuInt04, Mar. 2004, Laboratori Nazionali del Gran Sasso - INFN - Assergi, Italy [ http://nuint04.lngs.infn.it/])

  6. A tight and explicit representation of Q in sparse QR factorization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ng, E.G.; Peyton, B.W.

    1992-05-01

    In QR factorization of a sparse m{times}n matrix A (m {ge} n) the orthogonal factor Q is often stored implicitly as a lower trapezoidal matrix H known as the Householder matrix. This paper presents a simple characterization of the row structure of Q, which could be used as the basis for a sparse data structure that can store Q explicitly. The new characterization is a simple extension of a well known row-oriented characterization of the structure of H. Hare, Johnson, Olesky, and van den Driessche have recently provided a complete sparsity analysis of the QR factorization. Let U be themore » matrix consisting of the first n columns of Q. Using results from, we show that the data structures for H and U resulting from our characterizations are tight when A is a strong Hall matrix. We also show that H and the lower trapezoidal part of U have the same sparsity characterization when A is strong Hall. We then show that this characterization can be extended to any weak Hall matrix that has been permuted into block upper triangular form. Finally, we show that permuting to block triangular form never increases the fill incurred during the factorization.« less

  7. Improvement of vibration energy harvesters mechanical Q-factor through high density proof mass integration

    NASA Astrophysics Data System (ADS)

    Dompierre, A.; Fréchette, L. G.

    2016-11-01

    This paper reports on improvement of the mechanical Q-factor of resonant energy harvesters at ambient pressure via the use of tungsten proof masses by evaluating the impact of the mass size and density on the squeeze film damping. To this end, a simplified model is first proposed to evaluate cantilever beams deflection and the resulting fluid pressure build up between the mass and a near surface. The model, which accounts for simultaneous transverse and rotational motion of very long tip masses as well as for 2D fluid flow in the gap, is used to extract a scaling law for the device fluidic Q-factor Qf. This law states that Qf can be improved by either increasing the linear mass density of the tip mass or by reducing the side lengths compared to the gap height. The first approach is validated experimentally by adding a tungsten proof mass on a silicon based device and observing an improvement of the Q-factor by 103%, going from 430 to 871, while the resonance frequency drops from 457 to 127 Hz. In terms of fluidic Q-factor, this represents an increase from 562 to 1673. These results successfully demonstrate the benefits of integrating a tungsten mass to reduce the fluid losses while potentially reducing the device footprint.

  8. Correlation between gamma glutamyltransferase fractions and bone quality.

    PubMed

    Franzini, M; Nesti, A; Panetta, D; Fierabracci, V; Marchetti, S; Parchi, P D; Caponi, L; Paolicchi, A; Musetti, V; Salvadori, P; Edmin, M; Pucci, A; Bonicoli, E; Scaglione, M; Piolanti, N

    Gamma-glutamyltransferase (GGT) has been recently identified as a bone-resorbing factor. The aim of this study was to investigate the association between plasma GGT fractions levels and bone quality. Plasma GGT fractions were analysed by gel-filtration chromatography. Bone quality was established quantitatively by two micro-CT derived microarchitectural parameters: the BV/TV (mineralised bone volume/total volume), and the SMI (structure model index) that describes the rod-like (low resistant) or plate-like (high-resistant) shape of bone trabeculae. We enrolled 93 patients hospitalised for elective total hip replacement (group Arthrosis, n=46) or for proximal femoral fracture (group Fracture, n=47). Patients within the first quartile of BV/TV (Q1, osteoporotic patients, n=6) showed higher levels of b-GGT fraction [median (min-max): 3.37 (1.42–6.81)] compared to patients with normal bone density (fourth quartile Q4, n=10; 1.40 (0.83–4.36); p=0.0393]. Also, according to SMI, b-GGT value was higher in the subgroup with bone fragility [Q1, n=8: 1.36 (0.43–4.36); Q4, n=8: 5.10 (1.4 –7.60); p=0.0117]. In conclusion, patients characterised by fragile bone structure showed specifically higher levels of plasma b-GGT activity thus suggesting fractional GGT analysis as a possible biomarker in the diagnosis of osteoporosis.

  9. Hadamard Factorization of Stable Polynomials

    NASA Astrophysics Data System (ADS)

    Loredo-Villalobos, Carlos Arturo; Aguirre-Hernández, Baltazar

    2011-11-01

    The stable (Hurwitz) polynomials are important in the study of differential equations systems and control theory (see [7] and [19]). A property of these polynomials is related to Hadamard product. Consider two polynomials p,q ∈ R[x]:p(x) = anxn+an-1xn-1+...+a1x+a0q(x) = bmx m+bm-1xm-1+...+b1x+b0the Hadamard product (p × q) is defined as (p×q)(x) = akbkxk+ak-1bk-1xk-1+...+a1b1x+a0b0where k = min(m,n). Some results (see [16]) shows that if p,q ∈R[x] are stable polynomials then (p×q) is stable, also, i.e. the Hadamard product is closed; however, the reciprocal is not always true, that is, not all stable polynomial has a factorization into two stable polynomials the same degree n, if n> 4 (see [15]).In this work we will give some conditions to Hadamard factorization existence for stable polynomials.

  10. Relating transverse-momentum-dependent and collinear factorization theorems in a generalized formalism

    NASA Astrophysics Data System (ADS)

    Collins, J.; Gamberg, L.; Prokudin, A.; Rogers, T. C.; Sato, N.; Wang, B.

    2016-08-01

    We construct an improved implementation for combining transverse-momentum-dependent (TMD) factorization and collinear factorization. TMD factorization is suitable for low transverse momentum physics, while collinear factorization is suitable for high transverse momenta and for a cross section integrated over transverse momentum. The result is a modified version of the standard W +Y prescription traditionally used in the Collins-Soper-Sterman (CSS) formalism and related approaches. We further argue that questions regarding the shape and Q dependence of the cross sections at lower Q are largely governed by the matching to the Y term.

  11. Near-threshold neutral pion electroproduction at high momentum transfers and generalized form factors

    NASA Astrophysics Data System (ADS)

    Khetarpal, P.; Stoler, P.; Aznauryan, I. G.; Kubarovsky, V.; Adhikari, K. P.; Adikaram, D.; Aghasyan, M.; Amaryan, M. J.; Anderson, M. D.; Anefalos Pereira, S.; Anghinolfi, M.; Avakian, H.; Baghdasaryan, H.; Ball, J.; Baltzell, N. A.; Battaglieri, M.; Batourine, V.; Bedlinskiy, I.; Biselli, A. S.; Bono, J.; Boiarinov, S.; Briscoe, W. J.; Brooks, W. K.; Burkert, V. D.; Carman, D. S.; Celentano, A.; Charles, G.; Cole, P. L.; Contalbrigo, M.; Crede, V.; D'Angelo, A.; Dashyan, N.; De Vita, R.; De Sanctis, E.; Deur, A.; Djalali, C.; Doughty, D.; Dugger, M.; Dupre, R.; Egiyan, H.; El Alaoui, A.; El Fassi, L.; Eugenio, P.; Fedotov, G.; Fegan, S.; Fersch, R.; Fleming, J. A.; Fradi, A.; Gabrielyan, M. Y.; Garçon, M.; Gevorgyan, N.; Gilfoyle, G. P.; Giovanetti, K. L.; Girod, F. X.; Goetz, J. T.; Gohn, W.; Golovatch, E.; Gothe, R. W.; Griffioen, K. A.; Guegan, B.; Guidal, M.; Guo, L.; Hafidi, K.; Hakobyan, H.; Hanretty, C.; Harrison, N.; Hicks, K.; Ho, D.; Holtrop, M.; Hyde, C. E.; Ilieva, Y.; Ireland, D. G.; Ishkhanov, B. S.; Isupov, E. L.; Jo, H. S.; Joo, K.; Keller, D.; Khandaker, M.; Kim, A.; Kim, W.; Klein, F. J.; Koirala, S.; Kubarovsky, A.; Kuleshov, S. V.; Kvaltine, N. D.; Lewis, S.; Livingston, K.; Lu, H. Y.; MacGregor, I. J. D.; Mao, Y.; Martinez, D.; Mayer, M.; McKinnon, B.; Meyer, C. A.; Mineeva, T.; Mirazita, M.; Mokeev, V.; Montgomery, R. A.; Moutarde, H.; Munevar, E.; Munoz Camacho, C.; Nadel-Turonski, P.; Nasseripour, R.; Niccolai, S.; Niculescu, G.; Niculescu, I.; Osipenko, M.; Ostrovidov, A. I.; Pappalardo, L. L.; Paremuzyan, R.; Park, K.; Park, S.; Pasyuk, E.; Phelps, E.; Phillips, J. J.; Pisano, S.; Pogorelko, O.; Pozdniakov, S.; Price, J. W.; Procureur, S.; Protopopescu, D.; Puckett, A. J. R.; Raue, B. A.; Ricco, G.; Rimal, D.; Ripani, M.; Rosner, G.; Rossi, P.; Sabatié, F.; Saini, M. S.; Salgado, C.; Saylor, N. A.; Schott, D.; Schumacher, R. A.; Seder, E.; Seraydaryan, H.; Sharabian, Y. G.; Smith, G. D.; Sober, D. I.; Sokhan, D.; Stepanyan, S. S.; Stepanyan, S.; Strakovsky, I. I.; Strauch, S.; Taiuti, M.; Tang, W.; Taylor, C. E.; Tkachenko, S.; Ungaro, M.; Vernarsky, B.; Voskanyan, H.; Voutier, E.; Walford, N. K.; Weinstein, L. B.; Weygand, D. P.; Wood, M. H.; Zachariou, N.; Zhang, J.; Zhao, Z. W.; Zonta, I.

    2013-04-01

    We report the measurement of near-threshold neutral pion electroproduction cross sections and the extraction of the associated structure functions on the proton in the kinematic range Q2 from 2 to 4.5 GeV2 and W from 1.08 to 1.16 GeV. These measurements allow us to access the dominant pion-nucleon s-wave multipoles E0+ and S0+ in the near-threshold region. In the light-cone sum-rule framework (LCSR), these multipoles are related to the generalized form factors G1π0p(Q2) and G2π0p(Q2). The data are compared to these generalized form factors and the results for G1π0p(Q2) are found to be in good agreement with the LCSR predictions, but the level of agreement with G2π0p(Q2) is poor.

  12. Errors in Air Permeability Rationing as Key Sources of Construction Quality Risk Assessment

    NASA Astrophysics Data System (ADS)

    Popov, A. A.; Nitievski, A. A.; Ivanov, R. N.

    2018-04-01

    The article deals with different approaches to the valuation parameters of air permeability n50 and q50. Examples of erroneous conclusions about the state of the building are presented as well as the ways to obtain reliable results. There are obtained comparative data of the air permeability parameters on examples of buildings with different configuration and with different values of compactness factor.

  13. The feasibility of universal DLP-to-risk conversion coefficients for body CT protocols

    NASA Astrophysics Data System (ADS)

    Li, Xiang; Samei, Ehsan; Segars, W. Paul; Paulson, Erik K.; Frush, Donald P.

    2011-03-01

    The effective dose associated with computed tomography (CT) examinations is often estimated from dose-length product (DLP) using scanner-independent conversion coefficients. Such conversion coefficients are available for a small number of examinations, each covering an entire region of the body (e.g., head, neck, chest, abdomen and/or pelvis). Similar conversion coefficients, however, do not exist for examinations that cover a single organ or a sub-region of the body, as in the case of a multi-phase liver examination. In this study, we extended the DLP-to-effective dose conversion coefficient (k factor) to a wide range of body CT protocols and derived the corresponding DLP-to-cancer risk conversion coefficient (q factor). An extended cardiactorso (XCAT) computational model was used, which represented a reference adult male patient. A range of body CT protocols used in clinical practice were categorized based on anatomical regions examined into 10 protocol classes. A validated Monte Carlo program was used to estimate the organ dose associated with each protocol class. Assuming the reference model to be 20 years old, effective dose and risk index (an index of the total risk for cancer incidence) were then calculated and normalized by DLP to obtain the k and q factors. The k and q factors varied across protocol classes; the coefficients of variation were 28% and 9%, respectively. The small variation exhibited by the q factor suggested the feasibility of universal q factors for a wide range of body CT protocols.

  14. 1 million-Q optomechanical microdisk resonators for sensing with very large scale integration

    NASA Astrophysics Data System (ADS)

    Hermouet, M.; Sansa, M.; Banniard, L.; Fafin, A.; Gely, M.; Allain, P. E.; Santos, E. Gil; Favero, I.; Alava, T.; Jourdan, G.; Hentz, S.

    2018-02-01

    Cavity optomechanics have become a promising route towards the development of ultrasensitive sensors for a wide range of applications including mass, chemical and biological sensing. In this study, we demonstrate the potential of Very Large Scale Integration (VLSI) with state-of-the-art low-loss performance silicon optomechanical microdisks for sensing applications. We report microdisks exhibiting optical Whispering Gallery Modes (WGM) with 1 million quality factors, yielding high displacement sensitivity and strong coupling between optical WGMs and in-plane mechanical Radial Breathing Modes (RBM). Such high-Q microdisks with mechanical resonance frequencies in the 102 MHz range were fabricated on 200 mm wafers with Variable Shape Electron Beam lithography. Benefiting from ultrasensitive readout, their Brownian motion could be resolved with good Signal-to-Noise ratio at ambient pressure, as well as in liquid, despite high frequency operation and large fluidic damping: the mechanical quality factor reduced from few 103 in air to 10's in liquid, and the mechanical resonance frequency shifted down by a few percent. Proceeding one step further, we performed an all-optical operation of the resonators in air using a pump-probe scheme. Our results show our VLSI process is a viable approach for the next generation of sensors operating in vacuum, gas or liquid phase.

  15. Unprecedented quality factors at accelerating gradients up to 45 MVm -1 in niobium superconducting resonators via low temperature nitrogen infusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grassellino, A.; Romanenko, A.; Trenikhina, Y.

    We report the finding of new surface treatments that permit to manipulate the niobium resonator nitrogen content in the first few nanometers in a controlled way, and the resonator fundamental Mattis-Bardeen surface resistance and residual resistance accordingly. In particular, we find surface infusion conditions that systematically a) increase the quality factor of these 1.3 GHz superconducting radio frequency (SRF) bulk niobium resonators, up to very high gradients; b) increase the achievable accelerating gradient of the cavity compared to its own baseline with state-of-the-art surface processing. Cavities subject to the new surface process have larger than two times the state ofmore » the art Q at 2K for accelerating fields > 35 MV/m. Moreover, very high accelerating gradients ~ 45 MV/m are repeatedly reached, which correspond to peak magnetic surface fields of 190 mT, among the highest measured for bulk niobium cavities. These findings open the opportunity to tailor the surface impurity content distribution to maximize performance in Q and gradients, and have therefore very important implications on future performance and cost of SRF based accelerators. They also help deepen the understanding of the physics of the RF niobium cavity surface.« less

  16. Unprecedented quality factors at accelerating gradients up to 45 MVm-1 in niobium superconducting resonators via low temperature nitrogen infusion

    NASA Astrophysics Data System (ADS)

    Grassellino, A.; Romanenko, A.; Trenikhina, Y.; Checchin, M.; Martinello, M.; Melnychuk, O. S.; Chandrasekaran, S.; Sergatskov, D. A.; Posen, S.; Crawford, A. C.; Aderhold, S.; Bice, D.

    2017-09-01

    We report the finding of new surface treatments that permits one to manipulate the niobium resonator nitrogen content in the first few nanometers in a controlled way, and the resonator fundamental Mattis-Bardeen surface resistance and residual resistance accordingly. In particular, we find surface ‘infusion’ conditions that systematically (a) increase the quality factor of these 1.3 GHz superconducting radio frequency (SRF) bulk niobium resonators, up to very high gradients; (b) increase the achievable accelerating gradient of the cavity compared to its own baseline with state-of-the-art surface processing. Cavities subject to the new surface process have more than two times the state-of-the-art Q at 2 K for accelerating fields >35 MVm-1. Moreover, very high accelerating gradients ˜45 MVm-1 are repeatedly reached, which correspond to peak magnetic surface fields of 190 mT, among the highest measured for bulk niobium cavities. These findings open the opportunity to tailor the surface impurity content distribution to maximize performance in Q and gradients, and have therefore very important implications on future performance and cost of SRF based accelerators. They also help deepen the understanding of the physics of the RF niobium cavity surface.

  17. Coupling of ions to superconducting circuits

    NASA Astrophysics Data System (ADS)

    Moeller, Soenke; Daniilidis, Nikos; Haeffner, Hartmut

    2013-05-01

    We present experimental progress towards coupling the motion of ion strings to the resonant mode of a superconducting high-quality tank circuit. We consider such a coupling as the first step towards interfacing trapped ions with superconducting qubits. In our demonstration experiment, we aim to reduce the temperature of the resonant mode of the tank circuit by extracting energy from the circuit via laser cooling an ion string. One of the main experimental challenges is to construct a tank circuit with such a high quality factor Q that the ion-resonator coupling exceeds the environment-resonator coupling. Currently, we achieve Q = 60 000 at a frequency of ω = 2 π . 5 . 7 MHz . For this mode, the coupling time-scale to the environment is on the order of 50 Hz. We plan to use a trap with an ion-electrode distance on the order of 100 μm resulting in an ion-resonator coupling of 1kHz. This coupling should reduce the electronic temperature of the resonant mode by a factor of 80 below the ambient temperature. For our trap geometry we expect a minimum trap depth of 50 meV for a trap drive frequency of 52 MHz with a 200 V amplitude. This results radial trap frequencies of 5 . 7 MHz . Research funded by DARPA grant #N66001-12-1-4234.

  18. Superelastic and superhydrophobic bacterial cellulose/silica aerogels with hierarchical cellular structure for oil absorption and recovery.

    PubMed

    He, Jian; Zhao, Hangyuan; Li, Xiaolei; Su, Dong; Zhang, Fengrui; Ji, Huiming; Liu, Rui

    2018-03-15

    Bacterial cellulose aerogels/silica aerogels (BCAs/SAs) are prepared using three-dimensional self-assembled BC skeleton as reinforcement and methyltriethoxysilane derived silica aerogels as filler through vacuum infiltration and freeze drying. The BCAs/SAs possess a hierarchical cellular structure giving them superelasticity and recyclable compressibility. The BCAs/SAs can bear a compressive strain up to 80% and recover their original shapes after the release of the stress. The BCAs/SAs exhibit super-hydrophobicity with a contact angle of 152° and super-oleophilicity resulting from the methyl groups on the surface of silica aerogel filler. This endows the BCAs/SAs outstanding oil absorbing capability with the quality factor Q from 8 to 14 for organic solvents and oils. Moreover, the absorbed oil can be retrieved by mechanically squeezed with a recovery of 88% related to the superelastic ability of the composites. In addition, the oil absorbing of BS/SAs could be well maintained with the quality factor Q about 11 for gasoline after harsh conditional treatment down to -200 °C and up to 300 °C. Such outstanding elastic and oleophilic properties make the BC/SAs tremendous potential for applications of oil absorbing, recovery and oil-water separation. Copyright © 2017. Published by Elsevier B.V.

  19. Rsd family proteins make simultaneous interactions with regions 2 and 4 of the primary sigma factor

    PubMed Central

    Yuan, Andy H.; Gregory, Brian D.; Sharp, Josh S.; McCleary, Katherine D.; Dove, Simon L.; Hochschild, Ann

    2008-01-01

    Summary Bacterial anti-σ factors typically regulate σ factor function by restricting the access of their cognate σ factors to the RNA polymerase (RNAP) core enzyme. The E. coli Rsd protein forms a complex with the primary σ factor, σ70, inhibits σ70-dependent transcription in vitro, and has been proposed to function as a σ70-specific anti-σ factor, thereby facilitating the utilization of alternative σ factors. In prior work, Rsd has been shown to interact with conserved region 4 of σ70, but it is not known whether this interaction suffices to account for the regulatory functions of Rsd. Here we show that Rsd and the Rsd ortholog AlgQ, a global regulator of gene expression in P. aeruginosa, interact with conserved region 2 of σ70. We show further that Rsd and AlgQ can interact simultaneously with regions 2 and 4 of σ70. Our findings establish that the abilities of Rsd and AlgQ to interact with σ70 region 2 are important determinants of their in vitro and in vivo activities. PMID:18826409

  20. Rsd family proteins make simultaneous interactions with regions 2 and 4 of the primary sigma factor.

    PubMed

    Yuan, Andy H; Gregory, Brian D; Sharp, Josh S; McCleary, Katherine D; Dove, Simon L; Hochschild, Ann

    2008-12-01

    Bacterial anti-sigma factors typically regulate sigma factor function by restricting the access of their cognate sigma factors to the RNA polymerase (RNAP) core enzyme. The Escherichia coli Rsd protein forms a complex with the primary sigma factor, sigma(70), inhibits sigma(70)-dependent transcription in vitro, and has been proposed to function as a sigma(70)-specific anti-sigma factor, thereby facilitating the utilization of alternative sigma factors. In prior work, Rsd has been shown to interact with conserved region 4 of sigma(70), but it is not known whether this interaction suffices to account for the regulatory functions of Rsd. Here we show that Rsd and the Rsd orthologue AlgQ, a global regulator of gene expression in Pseudomonas aeruginosa, interact with conserved region 2 of sigma(70). We show further that Rsd and AlgQ can interact simultaneously with regions 2 and 4 of sigma(70). Our findings establish that the abilities of Rsd and AlgQ to interact with sigma(70) region 2 are important determinants of their in vitro and in vivo activities.

  1. Q fever in an endemic region of North Queensland, Australia: A 10 year review.

    PubMed

    Sivabalan, Pirathaban; Saboo, Apoorva; Yew, James; Norton, Robert

    2017-06-01

    Q fever is a zoonotic infection caused by Coxiella burnetii . Endemic Q fever has long been recognised in north Queensland, with north Queensland previously acknowledged to have the highest rate of notification in Australia. In this retrospective study, we reviewed the demographics and exposure of patients diagnosed with Q fever in an endemic region of north Queensland, to identify trends and exposure factors for the acquisition of Q fever. A retrospective study looking at patients in the region that had tested positive for Q fever by case ascertainment between 2004 and 2014. This involved both a chart review and the completion of a patient questionnaire targeting demographics, clinical presentation, risk factors and outcomes. There were 101 patients with a positive Q fever serology and/or PCR that were identified in the region of north Queensland that was studied, between 2004 and 2014. The cohort was residents of Mackay Hospital and Health Service. Of these, 4 patients were excluded and 63 patients successfully completed a questionnaire on demographic and risk factors. Out of the 63 patients, the highest prevalence was in the patients residing in the coastal region of Proserpine (42/100,000 people per year) followed by the Whitsundays region (14.8/100,000 people per year). A significantly higher proportion of patients were reportedly exposed to macropods (69.8%) and possums (66.7%) as compared to cattle (23.8%). A trend between increased cases of Q fever infection and high seasonal rainfall was noted. In this endemic region of north Queensland, exposure to wildlife and seasonal rainfall may be substantial exposure factors for the development of Q fever. The region studied is a popular tourist destination. An understanding of risk factors involved can help practitioners who see residents or returned travelers from the region, with an undifferentiated fever.

  2. Q fever is an old and neglected zoonotic disease in Kenya: a systematic review.

    PubMed

    Njeru, J; Henning, K; Pletz, M W; Heller, R; Neubauer, H

    2016-04-05

    Q fever is a neglected zoonosis caused by the bacterium Coxiella burnetii. The knowledge of the epidemiology of Q fever in Kenya is limited with no attention to control and prevention programs. The purpose of this review is to understand the situation of Q fever in human and animal populations in Kenya in the past 60 years, and help identify future research priorities for the country. Databases were searched for national and international scientific studies or reports on Q fever. We included studies and reports published between 1950 and 2015 if they reported on Q fever prevalence, incidence, and infection control programs in Kenya. Data were extracted with respect to studies on prevalence of Coxiella infections, study design, study region, the study populations involved, and sorted according to the year of the study. We identified 15 studies and reports which qualified for data extraction. Human seroprevalence studies revealed evidence of C. burnetii infections ranging from 3 to 35.8% in all regions in which surveys were made and two Q fever outbreak episodes. Coxiella burnetii infections found in cattle 7.4-51.1%, sheep 6.7-20%, camels 20-46%, and goats 20-46% revealed variation based on ecoregions and the year of study. Farming and lack of protective clothing were associated with increased seropositivity among humans. However, high quality data is lacking on Q fever awareness, underlying cultural-economic factors influencing C. burnetii infection, and how the pathogen cycles may be embedded in livestock production and management systems in the economically and ecologically different Kenyan regions. We found no studies on national disease incidence estimates or disease surveillance and control efforts. Coxiella burnetii infections are common in human and in a wide range of animal populations but are still unrecognized and underestimated thus presenting a significant human and animal health threat in Kenya. The factors influencing pathogen transmission, persistence and spread are poorly understood. Integrated disease surveillance and prevention/control programs are needed in Kenya.

  3. Analysis of nonreciprocal noise based on mode splitting in a high-Q optical microresonator

    NASA Astrophysics Data System (ADS)

    Yang, Zhaohua; Xiao, Yarong; Huo, Jiayan; Shao, Hui

    2018-01-01

    The whispering gallery mode optical microresonator offers a high quality factor, which enables it to act as the core component of a high sensitivity resonator optic gyro; however, nonreciprocal noise limits its precision. Considering the Sagnac effect, i.e. mode splitting in high-quality optical micro-resonators, we derive the explicit expression for the angular velocity versus the splitting amount, and verify the sensing mechanism by simulation using finite element method. Remarkably, the accuracy of the angular velocity measurement in the whispering gallery mode optical microresonator with a quality factor of 108 is 106 °/s. We obtain the optimal coupling position of the novel angular velocity sensing system by detecting the output transmittance spectra of different vertical coupling distances and axial coupling positions. In addition, the reason for the nonreciprocal phenomenon is determined by theoretical analysis of the evanescent distribution of a tapered fiber. These results will provide an effective method and a theoretical basis for suppression of the nonreciprocal noise.

  4. One-dimensional Multi-channel Photonic Crystal Resonators based on Silicon-On-Insulator with High Quality Factor

    NASA Astrophysics Data System (ADS)

    Faneca, Joaquin; Perova, Tatiana S.; Tolmachev, Vladimir; Baldycheva, Anna

    2018-05-01

    We have theoretically and experimentally demonstrated a Fabry-Pérot (FP) resonators based on a Si-air one-dimensional photonic crystal (1D PhC) with coupled triple-cavity modes (or defects). These defects are obtained by filling selected air channels in the 1D PhC with an actively reconfigurable fluid. Simulations of the optical properties of these FP resonators were performed in the wide infrared spectral range. It is shown that by changing the refractive index, nc, of the fluid simultaneously in all three channels, a set of narrow triple resonance peaks can be obtained within wide stop-bands of different order in the infrared range. In addition, at certain values of nc, splitting of the triple resonance peaks into a doublet and a single peak with a significantly larger quality factor, Q=21200, occurs. Prototype devices based on Silicon-On-Insulator platform were fabricated and characterized by electro-optical and spectroscopic measurements. The electro-optical measurements demonstrate the possibility of refractive index manipulation of the filler in the FP channels individually or simultaneously. Spectroscopic measurements performed in the range 1540 – 1630 nm using fibre-coupling confirm the presence of triple resonance peaks in the 3rd stop-band in the absence of an electric field applied to the FP channels. At an applied voltage of 10 V to the middle channel, an increase of Q to 3720 in the single peak is registered which is the highest Q demonstrated in SOI based 1D PhC to date.

  5. Multicenter evaluation of quality of life and patient satisfaction after breast reconstruction, a long-term retrospective study.

    PubMed

    Ménez, T; Michot, A; Tamburino, S; Weigert, R; Pinsolle, V

    2018-04-01

    Breast reconstruction techniques are multiple and they should be chosen in order to improve women's satisfaction and well-being, thus obtaining a personalized treatment. This report's major purpose was to study, through the Breast-Q questionnaire, how the functional and aesthetic outcomes, as well as the complications, of the main autologous breast reconstruction techniques, can affect patients quality of life and well-being at long-term. The secondary purpose was to analyse, thus to identify, the independent factors characterizing the different reconstructive techniques, which may affect patients' satisfaction. Women who underwent autologous breast reconstruction through deep inferior epigastric artery perforator or Latissimus dorsi muscle flap from May 2006 to May 2013 were included. The assessment was based on the Breast-Q reconstruction questionnaire. All times of post-mastectomy reconstruction were concerned: immediate, delayed, after previous procedure failure or conversion to another reconstructive technique due to the patient's dissatisfaction. A total of 98 patients were included. Concerning patients satisfaction, the breast-Q score is highest in patients who underwent immediate breast reconstruction, while scores after delayed breast reconstruction, previous surgery failure or conversion to another technique are generally equivalent. Higher scores have been observed in patients who underwent reconstruction through autologous Latissimus dorsi compared to Latissimus dorsi with prosthetic implant reconstruction. The authors identified factors of higher patients' satisfaction, like absence of major complication and advanced patient's age, in order to personalize the surgical planning according to the patient's priorities. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  6. Theoretical and experimental investigations on high peak power Q-switched Nd:YAG laser at 1112 nm

    NASA Astrophysics Data System (ADS)

    He, Miao; Yang, Feng; Wang, Zhi-Chao; Gao, Hong-Wei; Yuan, Lei; Li, Chen-Long; Zong, Nan; Shen, Yu; Bo, Yong; Peng, Qin-Jun; Cui, Da-Fu; Xu, Zu-Yan

    2018-07-01

    We report on the experimental measurement and theoretical analysis on a Q-switched high peak power laser diode (LD) side-pumped 1112 nm Nd:YAG laser by means of special mirrors coating design in cavity. In theory, a numerical model, based on four-wavelength rate equations, is performed to analyze the competition process of different gain lines and the output characteristics of the Q-switched Nd:YAG laser. In the experiment, a maximum output power of 25.2 W with beam quality factor M2 of 1.46 is obtained at the pulse repetition rate of 2 kHz and 210 ns of pulse width, corresponding to a pulse energy and peak power of 12.6 mJ and 60 kW, respectively. The experimental data agree well with the theoretical simulation results.

  7. Unequal density effect on static structure factor of coupled electron layers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saini, L. K., E-mail: lks@ashd.svnit.ac.in; Nayak, Mukesh G., E-mail: lks@ashd.svnit.ac.in

    In order to understand the ordered phase, if any, in a real coupled electron layers (CEL), there is a need to take into account the effect of unequal layer density. Such phase is confirmed by a strong peak in a static structure factor. With the aid of quantum/dynamical version of Singwi, Tosi, Land and Sjölander (so-called qSTLS) approximation, we have calculated the intra- and interlayer static structure factors, S{sub ll}(q) and S{sub 12}(q), over a wide range of density parameter r{sub sl} and interlayer spacing d. In our present study, the sharp peak in S{sub 22}(q) has been found atmore » critical density with sufficiently lower interlayer spacing. Further, to find the resultant effect of unequal density on intra- and interlayer static structure factors, we have compared our results with that of the recent CEL system with equal layer density and isolated single electron layer.« less

  8. Q-factor improvement of degenerate four-wave-mixing regenerators for ASE degraded signals

    NASA Astrophysics Data System (ADS)

    Lu, Hang; Wu, Bao-jian; Geng, Yong; Zhou, Xing-yu; Sun, Fan

    2017-11-01

    All-optical regenerators can be used to suppress amplified spontaneous emission (ASE) noise introduced by cascaded erbium doped fiber amplifiers (EDFAs) in optical fiber communication systems and lead to the improvement of optical receiver sensitivity. By introducing the Q-factor transfer function (QTF), we evaluate the Q-factor performance of degenerate four-wave mixing (DFWM) regenerators with clock pump and reveal the differences between the optimal input powers determined from the static and dynamic power tranfer function (PTF) and the QTF curves. Our simulation shows that the clock-pump regnerator is capable of improving the Q-facor and receiver sensitivity for 40 Gbit/s ASE-degraded return-to-zero on-off keying (RZ-OOK) signal by 2.58 dB and 4.2 dB, respectively.

  9. Assessment of ionization chamber correction factors in photon beams using a time saving strategy with PENELOPE code.

    PubMed

    Reis, C Q M; Nicolucci, P

    2016-02-01

    The purpose of this study was to investigate Monte Carlo-based perturbation and beam quality correction factors for ionization chambers in photon beams using a saving time strategy with PENELOPE code. Simulations for calculating absorbed doses to water using full spectra of photon beams impinging the whole water phantom and those using a phase-space file previously stored around the point of interest were performed and compared. The widely used NE2571 ionization chamber was modeled with PENELOPE using data from the literature in order to calculate absorbed doses to the air cavity of the chamber. Absorbed doses to water at reference depth were also calculated for providing the perturbation and beam quality correction factors for that chamber in high energy photon beams. Results obtained in this study show that simulations with phase-space files appropriately stored can be up to ten times shorter than using a full spectrum of photon beams in the input-file. Values of kQ and its components for the NE2571 ionization chamber showed good agreement with published values in the literature and are provided with typical statistical uncertainties of 0.2%. Comparisons to kQ values published in current dosimetry protocols such as the AAPM TG-51 and IAEA TRS-398 showed maximum percentage differences of 0.1% and 0.6% respectively. The proposed strategy presented a significant efficiency gain and can be applied for a variety of ionization chambers and clinical photon beams. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  10. Tunable Q-factor silicon microring resonators for ultra-low power parametric processes.

    PubMed

    Strain, Michael J; Lacava, Cosimo; Meriggi, Laura; Cristiani, Ilaria; Sorel, Marc

    2015-04-01

    A compact silicon ring resonator is demonstrated that allows simple electrical tuning of the ring coupling coefficient and Q-factor and therefore the resonant enhancement of on-chip nonlinear optical processes. Fabrication-induced variation in designed coupling fraction, crucial in the resonator performance, can be overcome using this post-fabrication trimming technique. Tuning of the microring resonator across the critical coupling point is demonstrated, exhibiting a Q-factor tunable between 9000 and 96,000. Consequently, resonantly enhanced four-wave mixing shows tunable efficiency between -40 and -16.3  dB at an ultra-low on-chip pump power of 0.7 mW.

  11. A lung sound classification system based on the rational dilation wavelet transform.

    PubMed

    Ulukaya, Sezer; Serbes, Gorkem; Sen, Ipek; Kahya, Yasemin P

    2016-08-01

    In this work, a wavelet based classification system that aims to discriminate crackle, normal and wheeze lung sounds is presented. While the previous works related with this problem use constant low Q-factor wavelets, which have limited frequency resolution and can not cope with oscillatory signals, in the proposed system, the Rational Dilation Wavelet Transform, whose Q-factors can be tuned, is employed. Proposed system yields an accuracy of 95 % for crackle, 97 % for wheeze, 93.50 % for normal and 95.17 % for total sound signal types using energy feature subset and proposed approach is superior to conventional low Q-factor wavelet analysis.

  12. Experimental and theoretical investigations of the quality factor for n+p silicon solar cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garlick, G.F.J.; Kachare, A.H.

    1980-01-01

    Many N/sup +/P silicon cells made with silicon from different growth techniques have current-voltage relations of the form: I.I/sub 0/ (exp(qV/AkT) - 1) where the quality factor A is non-integral, is >1 and shows a temperature dependence. The dark forward characteristics of such cells have been measured over a range of temperature and the behavior of the factor A derived from them. A new model is presented on the assumption of non-uniform distributions of recombination levels in the junction depletion layer. This model shows good agreement with experimental data. The cells investigated had evaporated top metallization and so the junctionmore » contamination giving the recombination levels is likely to be a result of junction diffusion and is not specific to the metallization processing. The model needs further development and evaluation in order to apply it to the illuminated cell behavior and also to include any effects of distributed sheet resistance in the N/sup +/ layer. 17 refs.« less

  13. Microstrip resonators for electron paramagnetic resonance experiments

    NASA Astrophysics Data System (ADS)

    Torrezan, A. C.; Mayer Alegre, T. P.; Medeiros-Ribeiro, G.

    2009-07-01

    In this article we evaluate the performance of an electron paramagnetic resonance (EPR) setup using a microstrip resonator (MR). The design and characterization of the resonator are described and parameters of importance to EPR and spin manipulation are examined, including cavity quality factor, filling factor, and microwave magnetic field in the sample region. Simulated microwave electric and magnetic field distributions in the resonator are also presented and compared with qualitative measurements of the field distribution obtained by a perturbation technique. Based on EPR experiments carried out with a standard marker at room temperature and a MR resonating at 8.17 GHz, the minimum detectable number of spins was found to be 5×1010 spins/GHz1/2 despite the low MR unloaded quality factor Q0=60. The functionality of the EPR setup was further evaluated at low temperature, where the spin resonance of Cr dopants present in a GaAs wafer was detected at 2.3 K. The design and characterization of a more versatile MR targeting an improved EPR sensitivity and featuring an integrated biasing circuit for the study of samples that require an electrical contact are also discussed.

  14. MO-FG-CAMPUS-IeP1-05: New Ionization Chamber Dosimetry of Absorbed Dose to Water in Diagnostic KV X-Ray Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Araki, F; Ohno, T

    Purpose: To develop new ionization chamber dosimetry of absorbed dose to water in diagnostic kV x-ray beams, by using a beam quality conversion factor, kQ, for Co-60 to kV x-ray and an ionization conversion factor for a water-substitute plastic phantom. Methods: kQ was calculated for aluminum half value-layers (Al-HVLs) of 1.5 mm to 8 mm which were generated by kV x-ray beams of 50 to 120 kVp. Twenty-two energy spectra for ten effective energies (Eeff) were calculated by a SpecCalc program. Depth doses in water were calculated at 5 × 5 to 30 × 30 cm{sup 2} fields. Output factorsmore » were also obtained from the dose ratio for a 10 × 10 cm{sup 2} field. kQ was obtained for a PTW30013 Former ion chamber. In addition, an ionization conversion factor of the PWDT phantom to water was calculated. All calculations were performed with EGSnrc/cavity code and egs-chamber codes. Results: The x-ray beam energies for 1.5 mm to 8 mm Al-HVLs ranged in Eeff of 25.7 to 54.3 keV. kQ for 1.5 mm to 8 mm Al-HVLs were 0.831 to 0.897, at 1 and 2 cm depths for a 10 × 10 cm2 field. Similarly, output factors for 5 × 5 to 30 × 30 cm{sup 2} fields were 0.937 to 1.033 for 25.7 keV and 0.857 to 1.168 for 54.3 keV. The depth dose in a PWDT phantom decreased up to 5% compared to that in water at depth of ten percent of maximum dose for 1.5 mm Al-HVL. The ionization ratios of water/PWDT phantoms for the PTW30013 chamber were 1.012 to 1.007 for 1.5 mm to 8 mm Al-HVLs at 1 cm depth. Conclusion: It became possible to directly measure the absorbed dose to water with the ionization chamber in diagnostic kV x-ray beams, by using kQ and the PWDT phantom.« less

  15. Factor Analysis and Counseling Research

    ERIC Educational Resources Information Center

    Weiss, David J.

    1970-01-01

    Topics discussed include factor analysis versus cluster analysis, analysis of Q correlation matrices, ipsativity and factor analysis, and tests for the significance of a correlation matrix prior to application of factor analytic techniques. Techniques for factor extraction discussed include principal components, canonical factor analysis, alpha…

  16. Comparison of k Q factors measured with a water calorimeter in flattening filter free (FFF) and conventional flattening filter (cFF) photon beams

    NASA Astrophysics Data System (ADS)

    de Prez, Leon; de Pooter, Jacco; Jansen, Bartel; Perik, Thijs; Wittkämper, Frits

    2018-02-01

    Recently flattening filter free (FFF) beams became available for application in modern radiotherapy. There are several advantages of FFF beams over conventional flattening filtered (cFF) beams, however differences in beam spectra at the point of interest in a phantom potentially affect the ion chamber response. Beams are also non-uniform over the length of a typical reference ion chamber and recombination is usually larger. Despite several studies describing FFF beam characteristics, only a limited number of studies investigated their effect on k Q factors. Some of those studies predicted significant discrepancies in k Q factors (0.4% up to 1.0%) if TPR20,10 based codes of practice (CoPs) were to be used. This study addresses the question to which extent k Q factors, based on a TPR20,10 CoP, can be applied in clinical reference dosimetry. It is the first study that compares k Q factors measured directly with an absorbed dose to water primary standard in FFF-cFF pairs of clinical photon beams. This was done with a transportable water calorimeter described elsewhere. The measurements corrected for recombination and beam radial non-uniformity were performed in FFF-cFF beam pairs at 6 MV and 10 MV of an Elekta Versa HD for a selection of three different Farmer-type ion chambers (eight serial numbers). The ratio of measured k Q factors of the FFF-cFF beam pairs were compared with the TPR20,10 CoPs of the NCS and IAEA and the %dd(10) x CoP of the AAPM. For the TPR20,10 based CoPs differences less than 0.23% were found in k Q factors between the corresponding FFF-cFF beams with standard uncertainties smaller than 0.35%, while for the %dd(10) x these differences were smaller than 0.46% and within the expanded uncertainty of the measurements. Based on the measurements made with the equipment described in this study the authors conclude that the k Q factors provided by the NCS-18 and IAEA TRS-398 codes of practice can be applied for flattening filter free beams without additional correction. However, existing codes of practice cannot be applied ignoring the significant volume averaging effect of the FFF beams over the ion chamber cavity. For this a corresponding volume averaging correction must be applied.

  17. Performance analysis of all-optical XOR gate with photonic crystal semiconductor optical amplifier-assisted Mach-Zehnder interferometer at 160 Gb/s

    NASA Astrophysics Data System (ADS)

    Kotb, Amer; Zoiros, Kyriakos E.

    2017-11-01

    The photonic crystal (PC) can be used to prohibit, confine, or control the propagation of light in a photonic band-gap. The performance of an ultrafast exclusive disjunction (XOR) gate-implemented with a photonic crystal semiconductor optical amplifier (PC-SOA)-assisted Mach-Zehnder interferometer (MZI) is numerically investigated and analyzed at a data rate of 160 Gb/s. The impact of the data signals and PC-SOA's critical parameters on the output quality factor (Q-factor) is examined and assessed. The simulation results demonstrate that the XOR gate which is based on the proposed scheme is capable of operating at the target data rate with logical correctness and high quality. This is achieved with better performance than when having conventional SOAs in the MZI, which justifies employing PC-SOAs as nonlinear elements.

  18. Hybrid III-V on Si grating as a broadband reflector and a high-Q resonator

    NASA Astrophysics Data System (ADS)

    Chung, Il-Sug; Taghizadeh, Alireza; Park, Gyeong Cheol

    2016-03-01

    Hybrid grating (HG) with a high-refractive-index cap layer added onto a high contrast grating (HCG), can provide a high reflectance close 100 % over a broader wavelength range than HCGs, or work as a ultrahigh quality (Q) factor resonator. The reflection and resonance properties of HGs have been investigated and the mechanisms leading to these properties are discussed. A HG reflector sample integrating a III-V cap layer with InGaAlAs quantum wells onto a Si grating has been fabricated and its reflection property has been characterized. The HG-based lasers have a promising prospect for silicon photonics light source or high-speed laser applications.

  19. High-Q resonant cavities for terahertz quantum cascade lasers.

    PubMed

    Campa, A; Consolino, L; Ravaro, M; Mazzotti, D; Vitiello, M S; Bartalini, S; De Natale, P

    2015-02-09

    We report on the realization and characterization of two different designs for resonant THz cavities, based on wire-grid polarizers as input/output couplers, and injected by a continuous-wave quantum cascade laser (QCL) emitting at 2.55 THz. A comparison between the measured resonators parameters and the expected theoretical values is reported. With achieved quality factor Q ≈ 2.5 × 10(5), these cavities show resonant peaks as narrow as few MHz, comparable with the typical Doppler linewidth of THz molecular transitions and slightly broader than the free-running QCL emission spectrum. The effects of the optical feedback from one cavity to the QCL are examined by using the other cavity as a frequency reference.

  20. Comparison of Integrated Radiation Transport Models with TEPC Measurements for the Average Quality Factors in Spaceflights

    NASA Technical Reports Server (NTRS)

    Kim, Myung-Hee Y.; Nikjoo, Hooshang; Dicello, John F.; Pisacane, Vincent; Cucinotta, Francis A.

    2007-01-01

    The purpose of this work is to test our theoretical model for the interpretation of radiation data measured in space. During the space missions astronauts are exposed to the complex field of radiation type and kinetic energies from galactic cosmic rays (GCR), trapped protons, and sometimes solar particle events (SPEs). The tissue equivalent proportional counter (TEPC) is a simple time-dependent approach for radiation monitoring for astronauts on board the International Space Station. Another and a newer approach to Microdosimetry is the use of silicon-on-insulator (SOI) technology launched on the MidSTAR-1 mission in low Earth orbit (LEO). In the radiation protection practice, the average quality factor of a radiation field is defined as a function of linear energy transfer (LET), Q(sub ave)(LET). However, TEPC measures the average quality factor as a function of the lineal energy y, Q(sub ave)(y), defined as the average energy deposition in a volume divided by the average chord length of the volume. Lineal energy, y, deviates from LET due to energy straggling, delta-ray escape or entry, and nuclear fragments produced in the detector volume. Monte Carlo track structure simulation was employed to obtain the response of a TEPC irradiated with charged particle for an equivalent site diameter of 1 micron of wall-less counter. The calculated data of the energy absorption in the wall-less counter were compiled for various y values for several ion types at various discrete projectile energy levels. For the simulation of TEPC response from the mixed radiation environments inside a spacecraft, such as, Space Shuttle and International Space Station, the complete microdosimetric TEPC response, f( y, E, Z), were calculated with the Monte Carlo theoretical results by using the first order Lagrangian interpolation for a monovariate function at a given y value (y = 0.1 keV/micron 5000 keV/micron) at any projectile energy level (E = 0.01 MeV/u to 50,000 MeV/u) of each specific radiation type (Z = 1 to 28). Because the anomalous response has been observed at large event sizes in the experiment due to the escape of energy out of sensitive volume by delta-rays and the entry of delta-rays from the high-density wall into the low-density gas-volume cavity, Monte Carlo simulation was also made for the response of a walled-TEPC with wall thickness 2 mm and density 1 g/cm(exp 3). The radius of cavity was set to 6.35 mm and a gas density 7.874 x 10(exp -5) g/cm(exp 3). The response of the walled- and the wall-less counters were compared. The average quality factor Q(sub ave)(y) for trapped protons on STS-89 demonstrated the good agreement between the model calculations and flight TEPC data as shown. Using an integrated space radiation model (this includes the transport codes HZETRN and BRYNTRN, the quantum nuclear interaction model QMSFRG) and the resultant response distribution functions of walled-TEPC from Monte-Carlo track simulations, we compared model calculations with walled-TEPC measurements from NASA missions in LEO and made predictions for the lunar and the Mars missions. The Q(sub ave)(y) values for the trapped or the solar protons ranged from 1.9-2.5. This over-estimates the Qave(LET) values which ranged from 1.4-1.6. Both quantities increase with shield thickness due to nuclear fragmentation. The Q(sub ave)(LET) for the complete GCR spectra was found to be 3.5-4.5, while flight TEPCs measured 2.9-3.4 for Q(sub ave)(y). The GCR values are decreasing with the shield thickness. Our analysis for a proper interpretation of data supports the use of TEPCs for monitoring space radiation environment.

  1. The multifacet graphically contracted function method. II. A general procedure for the parameterization of orthogonal matrices and its application to arc factors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shepard, Ron; Brozell, Scott R.; Gidofalvi, Gergely

    2014-08-14

    Practical algorithms are presented for the parameterization of orthogonal matrices Q ∈ R {sup m×n} in terms of the minimal number of essential parameters (φ). Both square n = m and rectangular n < m situations are examined. Two separate kinds of parameterizations are considered, one in which the individual columns of Q are distinct, and the other in which only Span(Q) is significant. The latter is relevant to chemical applications such as the representation of the arc factors in the multifacet graphically contracted function method and the representation of orbital coefficients in SCF and DFT methods. The parameterizations aremore » represented formally using products of elementary Householder reflector matrices. Standard mathematical libraries, such as LAPACK, may be used to perform the basic low-level factorization, reduction, and other algebraic operations. Some care must be taken with the choice of phase factors in order to ensure stability and continuity. The transformation of gradient arrays between the Q and (φ) parameterizations is also considered. Operation counts for all factorizations and transformations are determined. Numerical results are presented which demonstrate the robustness, stability, and accuracy of these algorithms.« less

  2. Oral Health Related Quality of Life among Tamil Speaking Adults Attending a Dental Institution in Chennai, Southern India.

    PubMed

    Appukuttan, Deva Priya; Tadepalli, Anupama; Victor, Dhayanand John; Dharuman, Smriti

    2016-10-01

    Oral Health-Related Quality of Life (OHRQoL) indicates an individual's perception of how their well-being and quality of life is influenced by oral health. It facilitates treatment planning, assessing patient centred treatment outcomes and satisfaction. The study aimed to identify the factors influencing OHRQoL among Tamil speaking South Indian adult population. Non-probability sampling was done and 199 subjects aged 20-70 years were recruited for this observational study. The subjects were requested to fill a survey form along with the validated Tamil General Oral Health Assessment Index (GOHAI-Tml) questionnaire in the waiting area following which clinical examination was done by a single experienced Periodontist. The mean score with standard deviation for physical dimension was 4.34±0.96, psychological dimension was 4.03±1.13 and pain was 4.05±1.09 on GOHAI. Greater impacts were seen for psychosocial dimensions like pleased with the appearance of teeth/denture Q7 (3.7±1.2), worried about the problems with teeth/denture Q9 (3.7±1) and pain or discomfort in teeth Q12 (3.8±1). Functions like swallowing Q3 (4.5±0.8) and speaking Q4 (4.6±0.7) were minimally affected. As age increased subjects perceived more negative impacts as indicated by lower ADD-GOHAI and higher SC-GOHAI scores (p<0.01). Subjects complaining of bad breath, bleeding gums and Temporomandibular Joint (TMJ) problems, reported poor OHRQoL (p<0.05). It was observed that as self-perceived oral and general health status deteriorated, OHRQoL also worsened (p<0.01). Subjects with missing teeth, cervical abrasion, restorations, gingival recession and mobility had more impacts on OHRQoL (p<0.05). Subjects diagnosed with periodontitis had lower OHRQoL as reported on the scale than gingivitis subjects (p<0.01). In this study minimal impact was seen in all the three dimensions assessed with GOHAI. Factors like age, education, employment status, income, self-reported oral health, self-perceived general health, satisfaction with oral health, perceived need for treatment and denture wearing status influenced perceived OHRQoL. Bad breath, bleeding gums, TMJ problems, more number of missing teeth, decayed teeth, cervical abrasion, gingival recession and mobility were associated with poor OHRQoL.

  3. SU-G-TeP1-03: Beam Quality Correction Factors for Linear Accelerator with and Without Flattening Filter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Czarnecki, D; Voigts-Rhetz, P von; Zink, K

    2016-06-15

    Purpose: The impact of removing the flattening filter on absolute dosimetry based on IAEA’s TPR-398 and AAPM’s TG-51 was investigated in this study using Monte Carlo simulations. Methods: The EGSnrc software package was used for all Monte Carlo simulations performed in this work. Five different ionization chambers and nine linear accelerator heads have been modeled according to technical drawings. To generate a flattening filter free radiation field the flattening filter was replaced by a 2 mm thick aluminum layer. Dose calculation in a water phantom were performed to calculate the beam quality correction factor k{sub Q} as a function ofmore » the beam quality specifiers %dd(10){sub x}, TPR{sub 20,10} and mean photon and electron energies at the point of measurement in photon fields with (WFF) and without flattening filter (FFF). Results: The beam quality correction factor as a function of %dd(10){sub x} differs systematically between FFF and WFF beams for all investigated ionization chambers. The largest difference of 1.8% was observed for the largest investigated Farmer-type ionization chamber with a sensitive volume of 0.69 cm{sup 3}. For ionization chambers with a smaller nominal sensitive volume (0.015 – 0.3 cm{sup 3}) the deviation was less than 0.4% between WFF and FFF beams for %dd(10){sub x} > 62%. The specifier TPR{sub 20,10} revealed only a good correlation between WFF and FFF beams (< 0.3%) for low energies. Conclusion: The results confirm that %dd(10){sub x} is a suitable beam quality specifier for FFF beams with an acceptable bias. The deviation depends on the volume of the ionization chamber. Using %dd(10){sub x} to predict k{sub Q} for a large volume chamber in a FFF photon field may lead to not acceptable errors according to the results of this study. This bias may be caused by the volume effect due to the inhomogeneous photon fields of FFF linear accelerators.« less

  4. Stochastic resonance in micro/nano cantilever sensors

    NASA Astrophysics Data System (ADS)

    Singh, Priyanka; Yadava, R. D. S.

    2018-05-01

    In this paper we present a comparative study on the stochastic resonance in micro/nano cantilever resonators due to fluctuations in the fundamental frequency or the damping coefficient. Considering DC+AC electrostatic actuation in the presence of zero-mean Gaussian noise with exponential autocorrelation we analyze stochastic resonance behaviors for the frequency and the damping fluctuations separately, and compare the effects of stochastic resonance on Q-factor of the resonators for different levels of damping losses. It is found that even though the stochastic resonance occurs for both types of fluctuations, only the damping fluctuation produces right cooperative influence on the fundamental resonance that improves both the amplitude response and the quality factor of the resonator.

  5. Double Q-switch Ho:Sc2SiO5 laser by acousto-optic modulator combined with Cr2+:ZnSe saturable absorber

    NASA Astrophysics Data System (ADS)

    Yang, Xiao-tao; Zhang, Peng; Xie, Wen-qiang; Li, Lin-jun

    2018-01-01

    A double Q-switch (DQS) Ho:Sc2SiO5 laser modulated by a acousto-optic modulators (AOM) combined with a Cr2+:ZnSe saturable absorber (SA) was reported for the first time. The actively Q-switch (AQS) and passively Q-switch (PQS) were also studied. For the DQS mode, a maximum average output power of 2.49 W under the incident pump power of 12.5 W was obtained, corresponding to a slope efficiency of 24%. The characteristics of the DQS Ho:SSO laser versus different repetition frequencies (RF) of the AOM were researched. The maximum single-pulse energy of the DQS Ho:SSO laser was calculated to 1.98 mJ. The maximum peak power of the DQS Ho:SSO laser was 49.5 kW. The output beam quality factor M2 of DQS Ho:SSO laser was measured to be 1.15 with the highest peak power by knife-edge method at different positions.

  6. Transcriptomic and proteomic landscape of mitochondrial dysfunction reveals secondary coenzyme Q deficiency in mammals

    PubMed Central

    Atanassov, Ilian; Kuznetsova, Irina; Hinze, Yvonne; Mourier, Arnaud; Filipovska, Aleksandra

    2017-01-01

    Dysfunction of the oxidative phosphorylation (OXPHOS) system is a major cause of human disease and the cellular consequences are highly complex. Here, we present comparative analyses of mitochondrial proteomes, cellular transcriptomes and targeted metabolomics of five knockout mouse strains deficient in essential factors required for mitochondrial DNA gene expression, leading to OXPHOS dysfunction. Moreover, we describe sequential protein changes during post-natal development and progressive OXPHOS dysfunction in time course analyses in control mice and a middle lifespan knockout, respectively. Very unexpectedly, we identify a new response pathway to OXPHOS dysfunction in which the intra-mitochondrial synthesis of coenzyme Q (ubiquinone, Q) and Q levels are profoundly decreased, pointing towards novel possibilities for therapy. Our extensive omics analyses provide a high-quality resource of altered gene expression patterns under severe OXPHOS deficiency comparing several mouse models, that will deepen our understanding, open avenues for research and provide an important reference for diagnosis and treatment. PMID:29132502

  7. Excitonic Emission of Monolayer Semiconductors Near-Field Coupled to High-Q Microresonators

    NASA Astrophysics Data System (ADS)

    Javerzac-Galy, Clément; Kumar, Anshuman; Schilling, Ryan D.; Piro, Nicolas; Khorasani, Sina; Barbone, Matteo; Goykhman, Ilya; Khurgin, Jacob B.; Ferrari, Andrea C.; Kippenberg, Tobias J.

    2018-05-01

    We present quantum yield measurements of single layer $\\textrm{WSe}_2$ (1L-$\\textrm{WSe}_2$) integrated with high-Q ($Q>10^6$) optical microdisk cavities, using an efficient ($\\eta>$90%) near-field coupling scheme based on a tapered optical fiber. Coupling of the excitonic emission is achieved by placing 1L-WSe$_2$ to the evanescent cavity field. This preserves the microresonator high intrinsic quality factor ($Q>10^6$) below the bandgap of 1L-WSe$_2$. The nonlinear excitation power dependence of the cavity quantum yield is in agreement with an exciton-exciton annihilation model. The cavity quantum yield is $\\textrm{QY}_\\textrm{c}\\sim10^{-3}$, consistent with operation in the \\textit{broad emitter} regime (i.e. the emission lifetime of 1L-WSe$_2$ is significantly shorter than the bare cavity decay time). This scheme can serve as a precise measurement tool for the excitonic emission of layered materials into cavity modes, for both in plane and out of plane excitation.

  8. Proton and neutron electromagnetic form factors and uncertainties

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ye, Zhihong; Arrington, John; Hill, Richard J.

    We determine the nucleon electromagnetic form factors and their uncertainties from world electron scattering data. The analysis incorporates two-photon exchange corrections, constraints on the low-Q 2 and high-Q 2 behavior, and additional uncertainties to account for tensions between different data sets and uncertainties in radiative corrections.

  9. Proton and neutron electromagnetic form factors and uncertainties

    DOE PAGES

    Ye, Zhihong; Arrington, John; Hill, Richard J.; ...

    2017-12-06

    We determine the nucleon electromagnetic form factors and their uncertainties from world electron scattering data. The analysis incorporates two-photon exchange corrections, constraints on the low-Q 2 and high-Q 2 behavior, and additional uncertainties to account for tensions between different data sets and uncertainties in radiative corrections.

  10. Daycare Children of Divorce and Their Helpers

    ERIC Educational Resources Information Center

    Overland, Klara; Storksen, Ingunn; Thorsen, Arlene Arstad

    2013-01-01

    Caring for children of divorce may prevent emotional and behavioural problems. This study investigates daycare staff's beliefs about caring for young children who have experienced parental divorce. Q methodology was applied for this purpose, and 33 participants sorted 40 subjective statements. The Q factor analyses resulted in four factors or…

  11. Spatial association between dissection density and environmental factors over the entire conterminous United States

    NASA Astrophysics Data System (ADS)

    Luo, Wei; Jasiewicz, Jaroslaw; Stepinski, Tomasz; Wang, Jinfeng; Xu, Chengdong; Cang, Xuezhi

    2016-01-01

    Previous studies of land dissection density (D) often find contradictory results regarding factors controlling its spatial variation. We hypothesize that the dominant controlling factors (and the interactions between them) vary from region to region due to differences in each region's local characteristics and geologic history. We test this hypothesis by applying a geographical detector method to eight physiographic divisions of the conterminous United States and identify the dominant factor(s) in each. The geographical detector method computes the power of determinant (q) that quantitatively measures the affinity between the factor considered and D. Results show that the factor (or factor combination) with the largest q value is different for physiographic regions with different characteristics and geologic histories. For example, lithology dominates in mountainous regions, curvature dominates in plains, and glaciation dominates in previously glaciated areas. The geographical detector method offers an objective framework for revealing factors controlling Earth surface processes.

  12. Psychometric Properties of the Eating Disorder Examination Questionnaire (EDE-Q) and Norms for Rural and Urban Adolescent Males and Females in Mexico

    PubMed Central

    Penelo, Eva; Raich, Rosa M.

    2013-01-01

    Aims To contribute new evidence to the controversy about the factor structure of the Eating Disorder Examination Questionnaire (EDE-Q) and to provide, for the first time, norms based on a large adolescent Mexican community sample, regarding sex and area of residence (urban/rural). Methods A total of 2928 schoolchildren (1544 females and 1384 males) aged 11-18 were assessed with the EDE-Q and other disordered eating questionnaire measures. Results Confirmatory factor analysis of the attitudinal items of the EDE-Q did not support the four theorized subscales, and a two-factor solution, Restraint and Eating-Shape-Weight concern, showed better fit than the other models examined (RMSEA = .054); measurement invariance for this two-factor model across sex and area of residence was found. Satisfactory internal consistency (ω ≥ .80) and two-week test-retest reliability (ICCa ≥ .84; κ ≥ .56), and evidence for convergent validity with external measures was obtained. The highest attitudinal EDE-Q scores were found for urban females and the lowest scores were found for rural males, whereas the occurrence of key eating disorder behavioural features and compensatory behaviours was similar in both areas of residence. Conclusions This study reveals satisfactory psychometric properties and provides population norms of the EDE-Q, which may help clinicians and researchers to interpret the EDE-Q scores of adolescents from urban and rural areas in Mexico. PMID:24367587

  13. Ultra High Quality Factor Microtoroid for Chemical and Biomedical Sensing Applications

    DTIC Science & Technology

    2013-08-01

    PERFORMING ORGANIZATION NAMES AND ADDRESSES U.S. Army Research Office P.O. Box 12211 Research Triangle Park, NC 27709-2211 15. SUBJECT TERMS resonator...PERFORMING ORGANIZATION REPORT NUMBER 19a. NAME OF RESPONSIBLE PERSON 19b. TELEPHONE NUMBER Lan Yang 314-935-9543 3. DATES COVERED (From - To...change. By using this ultra high-Q WGM resonator, radius >75nm polystyrene nanoparticle are detected in aquatic environment. In addition to polystyrene

  14. Temperature Compensation of Aluminum Nitride Lamb Wave Resonators Utilizing the Lowest-Order Symmetric Mode

    DTIC Science & Technology

    2012-12-14

    PZT ceramic plate [40]. Since then Lamb wave devices utilizing the lowest-order antisymmetric (A0) mode propagation in ZnO thin plate were widely...Million Pt Platinum PVDF Polyvinylidene Flouride PZT Lead Zirconium Titanate Q Quality Factor R Resistor RIE Reactive Ion Etching Rm Motional...GaAs), silicon carbide (SiC), langasite (LGS), lead zirconium titanate ( PZT ), and polyvinylidene flouride (PVDF). Each piezoelectric material has

  15. A comparative study of the effects of cone-plate and parallel-plate geometries on rheological properties under oscillatory shear flow

    NASA Astrophysics Data System (ADS)

    Song, Hyeong Yong; Salehiyan, Reza; Li, Xiaolei; Lee, Seung Hak; Hyun, Kyu

    2017-11-01

    In this study, the effects of cone-plate (C/P) and parallel-plate (P/P) geometries were investigated on the rheological properties of various complex fluids, e.g. single-phase (polymer melts and solutions) and multiphase systems (polymer blend and nanocomposite, and suspension). Small amplitude oscillatory shear (SAOS) tests were carried out to compare linear rheological responses while nonlinear responses were compared using large amplitude oscillatory shear (LAOS) tests at different frequencies. Moreover, Fourier-transform (FT)-rheology method was used to analyze the nonlinear responses under LAOS flow. Experimental results were compared with predictions obtained by single-point correction and shear rate correction. For all systems, SAOS data measured by C/P and P/P coincide with each other, but results showed discordance between C/P and P/P measurements in the nonlinear regime. For all systems except xanthan gum solutions, first-harmonic moduli were corrected using a single horizontal shift factor, whereas FT rheology-based nonlinear parameters ( I 3/1, I 5/1, Q 3, and Q 5) were corrected using vertical shift factors that are well predicted by single-point correction. Xanthan gum solutions exhibited anomalous corrections. Their first-harmonic Fourier moduli were superposed using a horizontal shift factor predicted by shear rate correction applicable to highly shear thinning fluids. The distinguished corrections were observed for FT rheology-based nonlinear parameters. I 3/1 and I 5/1 were superposed by horizontal shifts, while the other systems displayed vertical shifts of I 3/1 and I 5/1. Q 3 and Q 5 of xanthan gum solutions were corrected using both horizontal and vertical shift factors. In particular, the obtained vertical shift factors for Q 3 and Q 5 were twice as large as predictions made by single-point correction. Such larger values are rationalized by the definitions of Q 3 and Q 5. These results highlight the significance of horizontal shift corrections in nonlinear oscillatory shear data.

  16. Trends of microwave dielectric materials for antenna application

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sulong, T. A. T., E-mail: tuanamirahtuansulong@gmail.com; Osman, R. A. M., E-mail: rozana@unimap.edu.my; Idris, M. S., E-mail: sobri@unimap.edu.my

    Rapid development of a modern microwave communication system requires a high quality microwave dielectric ceramic material to be used as mobile and satellite communication. High permittivity of dielectric ceramics leads to fabrication of compact device for electronic components. Dielectric ceramics which used for microwave applications required three important parameters such as high or appropriate permittivity (ε{sub r}), high quality factor (Q {sub f} ≥ 5000 GH z) and good temperature coefficient of resonant frequency (τ{sub f}). This paper review of various dielectric ceramic materials used as microwave dielectric materials and related parameters for antenna applications.

  17. Replication of a Modified Factor Structure for the Eating Disorder Examination-Questionnaire: Extension to Clinical Eating Disorder and Non-clinical Samples in Portugal.

    PubMed

    Machado, Paulo P P; Grilo, Carlos M; Crosby, Ross D

    2018-01-01

    Psychometric investigations of the Eating Disorder Examination-Questionnaire (EDE-Q) have generally not supported the original scale structure. The present study tested an alternative brief factor structure in two large Portuguese samples: (1) a non-clinical sample of N = 4117 female students and (2) a treatment-seeking sample of N = 609 patients diagnosed with eating disorders. Confirmatory factor analysis revealed a poor fit for the original EDE-Q structure in both the non-clinical and the clinical samples but revealed a good fit for the alternative 7-item 3-factor structure (dietary restraint, shape/weight overvaluation and body dissatisfaction). Factor loadings were invariant across samples and across the different specific eating disorder diagnoses in the clinical sample. These confirmatory factor analysis findings, which replicate findings from studies with diverse predominately overweight/obese samples, supported a modified 7-item, 3-factor structure for the EDE-Q. The reliable findings across different non-clinical and clinical eating disorder groups provide confidence regarding the potential utility of this brief version. Copyright © 2017 John Wiley & Sons, Ltd and Eating Disorders Association. Copyright © 2017 John Wiley & Sons, Ltd and Eating Disorders Association.

  18. High-temperature superconducting radiofrequency probe for magnetic resonance imaging applications operated below ambient pressure in a simple liquid-nitrogen cryostat

    NASA Astrophysics Data System (ADS)

    Lambert, Simon; Ginefri, Jean-Christophe; Poirier-Quinot, Marie; Darrasse, Luc

    2013-05-01

    The present work investigates the joined effects of temperature and static magnetic field on the electrical properties of a 64 MHz planar high-temperature superconducting (HTS) coil, in order to enhance the signal-to-noise ratio (SNR) in nuclear magnetic resonance (NMR) applications with a moderate decrease of the HTS coil temperature (THTS). Temperature control is provided with accuracy better than 0.1 K from 80 to 66 K by regulating the pressure of the liquid nitrogen bath of a dedicated cryostat. The actual temperature of the HTS coil is obtained using a straightforward wireless method that eliminates the risks of coupling electromagnetic interference to the HTS coil and of disturbing the static magnetic field by DC currents near the region of interest. The resonance frequency ( f0) and the quality factor (Q) of the HTS coil are measured as a function of temperature in the 0-4.7 T field range with parallel and orthogonal orientations relative to the coil plane. The intrinsic HTS coil sensitivity and the detuning effect are then analyzed from the Q and f0 data. In the presence of the static magnetic field, the initial value of f0 in Earth's field could be entirely recovered by decreasing THTS, except for the orthogonal orientation above 1 T. The improvement of Q by lowering THTS was substantial. From 80 to 66 K, Q was multiplied by a factor of 6 at 1.5 T in orthogonal orientation. In parallel orientation, the maximum measured improvement of Q from 80 K to 66 K was a factor of 2. From 80 to 66 K, the improvement of the RF sensitivity relative to the initial value at the Earth's field and ambient pressure was up to 4.4 dB in parallel orientation. It was even more important in orthogonal orientation and continued to increase, up to 8.4 dB, at the maximum explored field of 1.5 T. Assuming that the noise contributions from the RF receiver are negligible, the SNR improvement using enhanced HTS coil cooling in NMR experiments was extracted from Q measurements either with or without the presence of the sample. Notably, the additional cooling in the presence of conductive samples appears more beneficial at higher field strengths and with an orthogonal incidence than with parallel. The temperature range accessible here, involving a relatively straightforward cryogenic design, brings a gain in RF sensitivity that is of great significance to cutting-edge applications with very weakly conducting samples, small biological specimens, or small animals in vivo. This work also demonstrates a better tolerance to thin-film orientation misalignments relative to the magnetic field, and this could eventually play a role in designing effective non-planar HTS coils or coil arrays which include elements of various orientations. Finally, the data provided in this work may help understand some critical aspects in the design of HTS coils for NMR and MRI applications and accounts for the presence of the static magnetic field, particularly regarding the SNR loss due to a decreased quality factor and detuning issues.

  19. Insights in the Fruit Flesh Browning Mechanisms in Solanum melongena Genetic Lines with Opposite Postcut Behavior.

    PubMed

    Docimo, T; Francese, G; De Palma, M; Mennella, D; Toppino, L; Lo Scalzo, R; Mennella, G; Tucci, M

    2016-06-08

    Color, taste, flavor, nutritional value, and shelf life are important factors determining quality and healthiness of food and vegetables. These factors are strongly affected by browning processes, occurring after fruit or vegetable cutting. Characterization of ten eggplant genotypes for chlorogenic acid (CGA) content, total phenols (TP), polyphenoloxidase (PPO) activity, and browning tendency corroborated a lack of significant correlations between biochemical factors and fruit flesh browning. Further in-depth molecular and biochemical analyses of two divergent eggplant genetic lines, AM199 (high browning) and AM086 (low browning), within 30 min from cutting, highlighted differences in the physiological mechanisms underlying the browning process. qRT-PCR analysis revealed distinct activation mechanisms of CGA biosynthetic and PPO genes in the two genetic lines. Metabolic data on CGA, sugars, and ascorbic acid contents confirmed that their different browning tendency matched with different metabolic responses to cutting. Our findings suggest that the complex mechanism of flesh browning in the two eggplant genetic lines might be mediated by multiple specific factors.

  20. Individual and Interactive Effects of Socio-Ecological Factors on Dengue Fever at Fine Spatial Scale: A Geographical Detector-Based Analysis

    PubMed Central

    Li, Xing; Wang, Jin; Lin, Hualiang; Chen, Lingling; Wu, Zhifeng; Ma, Wenjun

    2017-01-01

    Background: Large spatial heterogeneity was observed in the dengue fever outbreak in Guangzhou in 2014, however, the underlying reasons remain unknown. We examined whether socio-ecological factors affected the spatial distribution and their interactive effects. Methods: Moran’s I was applied to first examine the spatial cluster of dengue fever in Guangzhou. Nine socio-ecological factors were chosen to represent the urbanization level, economy, accessibility, environment, and the weather of the 167 townships/streets in Guangzhou, and then the geographical detector was applied to analyze the individual and interactive effects of these factors on the dengue outbreak. Results: Four clusters of dengue fever were identified in Guangzhou in 2014, including one hot spot in the central area of Guangzhou and three cold spots in the suburban districts. For individual effects, the temperature (q = 0.33) was the dominant factor of dengue fever, followed by precipitation (q = 0.24), road density (q = 0.24), and water body area (q = 0.23). For the interactive effects, the combination of high precipitation, high temperature, and high road density might result in increased dengue fever incidence. Moreover, urban villages might be the dengue fever hot spots. Conclusions: Our study suggests that some socio-ecological factors might either separately or jointly influence the spatial distribution of dengue fever in Guangzhou. PMID:28714925

  1. Individual and Interactive Effects of Socio-Ecological Factors on Dengue Fever at Fine Spatial Scale: A Geographical Detector-Based Analysis.

    PubMed

    Cao, Zheng; Liu, Tao; Li, Xing; Wang, Jin; Lin, Hualiang; Chen, Lingling; Wu, Zhifeng; Ma, Wenjun

    2017-07-17

    Background : Large spatial heterogeneity was observed in the dengue fever outbreak in Guangzhou in 2014, however, the underlying reasons remain unknown. We examined whether socio-ecological factors affected the spatial distribution and their interactive effects. Methods : Moran's I was applied to first examine the spatial cluster of dengue fever in Guangzhou. Nine socio-ecological factors were chosen to represent the urbanization level, economy, accessibility, environment, and the weather of the 167 townships/streets in Guangzhou, and then the geographical detector was applied to analyze the individual and interactive effects of these factors on the dengue outbreak. Results : Four clusters of dengue fever were identified in Guangzhou in 2014, including one hot spot in the central area of Guangzhou and three cold spots in the suburban districts. For individual effects, the temperature ( q = 0.33) was the dominant factor of dengue fever, followed by precipitation ( q = 0.24), road density ( q = 0.24), and water body area ( q = 0.23). For the interactive effects, the combination of high precipitation, high temperature, and high road density might result in increased dengue fever incidence. Moreover, urban villages might be the dengue fever hot spots. Conclusions : Our study suggests that some socio-ecological factors might either separately or jointly influence the spatial distribution of dengue fever in Guangzhou.

  2. How users adopt healthcare information: An empirical study of an online Q&A community.

    PubMed

    Jin, Jiahua; Yan, Xiangbin; Li, Yijun; Li, Yumei

    2016-02-01

    The emergence of social media technology has led to the creation of many online healthcare communities, where patients can easily share and look for healthcare-related information from peers who have experienced a similar problem. However, with increased user-generated content, there is a need to constantly analyse which content should be trusted as one sifts through enormous amounts of healthcare information. This study aims to explore patients' healthcare information seeking behavior in online communities. Based on dual-process theory and the knowledge adoption model, we proposed a healthcare information adoption model for online communities. This model highlights that information quality, emotional support, and source credibility are antecedent variables of adoption likelihood of healthcare information, and competition among repliers and involvement of recipients moderate the relationship between the antecedent variables and adoption likelihood. Empirical data were collected from the healthcare module of China's biggest Q&A community-Baidu Knows. Text mining techniques were adopted to calculate the information quality and emotional support contained in each reply text. A binary logistics regression model and hierarchical regression approach were employed to test the proposed conceptual model. Information quality, emotional support, and source credibility have significant and positive impact on healthcare information adoption likelihood, and among these factors, information quality has the biggest impact on a patient's adoption decision. In addition, competition among repliers and involvement of recipients were tested as moderating effects between these antecedent factors and the adoption likelihood. Results indicate competition among repliers positively moderates the relationship between source credibility and adoption likelihood, and recipients' involvement positively moderates the relationship between information quality, source credibility, and adoption decision. In addition to information quality and source credibility, emotional support has significant positive impact on individuals' healthcare information adoption decisions. Moreover, the relationships between information quality, source credibility, emotional support, and adoption decision are moderated by competition among repliers and involvement of recipients. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  3. Packaged silica microsphere-taper coupling system for robust thermal sensing application.

    PubMed

    Yan, Ying-Zhan; Zou, Chang-Ling; Yan, Shu-Bin; Sun, Fang-Wen; Ji, Zhe; Liu, Jun; Zhang, Yu-Guang; Wang, Li; Xue, Chen-Yang; Zhang, Wen-Dong; Han, Zheng-Fu; Xiong, Ji-Jun

    2011-03-28

    We propose and realize a novel packaged microsphere-taper coupling structure (PMTCS) with a high quality factor (Q) up to 5×10(6) by using the low refractive index (RI) ultraviolet (UV) glue as the coating material. The optical loss of the PMTCS is analyzed experimentally and theoretically, which indicate that the Q is limited by the glue absorption and the radiation loss. Moreover, to verify the practicability of the PMTCS, thermal sensing experiments are carried out, showing the excellent convenience and anti-jamming ability of the PMTCS with a high temperature resolution of 1.1×10(-3) ◦C. The experiments also demonstrate that the PMTCS holds predominant advantages, such as the robustness, mobility, isolation, and the PMTCS can maintain the high Q for a long time. The above advantages make the PMTCS strikingly attractive and potential in the fiber-integrated sensors and laser.

  4. Effect of material constants on power output in piezoelectric vibration-based generators.

    PubMed

    Takeda, Hiroaki; Mihara, Kensuke; Yoshimura, Tomohiro; Hoshina, Takuya; Tsurumi, Takaaki

    2011-09-01

    A possible power output estimation based on material constants in piezoelectric vibration-based generators is proposed. A modified equivalent circuit model of the generator was built and was validated by the measurement results in the generator fabricated using potassium sodium niobate-based and lead zirconate titanate (PZT) ceramics. Subsequently, generators with the same structure using other PZT-based and bismuth-layered structure ferroelectrics ceramics were fabricated and tested. The power outputs of these generators were expressed as a linear functions of the term composed of electromechanical coupling coefficients k(sys)(2) and mechanical quality factors Q*(m) of the generator. The relationship between device constants (k(sys)(2) and Q*(m)) and material constants (k(31)(2) and Q(m)) was clarified. Estimation of the power output using material constants is demonstrated and the appropriate piezoelectric material for the generator is suggested.

  5. Tidal Evolution of Asteroidal Binaries. Ruled by Viscosity. Ignorant of Rigidity.

    NASA Astrophysics Data System (ADS)

    Efroimsky, Michael

    2015-10-01

    This is a pilot paper serving as a launching pad for study of orbital and spin evolution of binary asteroids. The rate of tidal evolution of asteroidal binaries is defined by the dynamical Love numbers kl divided by quality factors Q. Common in the literature is the (oftentimes illegitimate) approximation of the dynamical Love numbers with their static counterparts. Since the static Love numbers are, approximately, proportional to the inverse rigidity, this renders a popular fallacy that the tidal evolution rate is determined by the product of the rigidity by the quality factor: {k}l/Q\\propto 1/(μ Q). In reality, the dynamical Love numbers depend on the tidal frequency and all rheological parameters of the tidally perturbed body (not just rigidity). We demonstrate that in asteroidal binaries the rigidity of their components plays virtually no role in tidal friction and tidal lagging, and thereby has almost no influence on the intensity of tidal interactions (tidal torques, tidal dissipation, tidally induced changes of the orbit). A key quantity that overwhelmingly determines the tidal evolution is a product of the effective viscosity η by the tidal frequency χ . The functional form of the torque’s dependence on this product depends on who wins in the competition between viscosity and self-gravitation. Hence a quantitative criterion, to distinguish between two regimes. For higher values of η χ , we get {k}l/Q\\propto 1/(η χ ), {while} for lower values we obtain {k}l/Q\\propto η χ . Our study rests on an assumption that asteroids can be treated as Maxwell bodies. Applicable to rigid rocks at low frequencies, this approximation is used here also for rubble piles, due to the lack of a better model. In the future, as we learn more about mechanics of granular mixtures in a weak gravity field, we may have to amend the tidal theory with other rheological parameters, ones that do not show up in the description of viscoelastic bodies. This line of study provides a tool to exploring the orbital history of asteroidal pairs, as well as of their final spin states.

  6. Fiber ring resonator based opto-electronic oscillator: phase noise optimisation and thermal stability study

    NASA Astrophysics Data System (ADS)

    Saleh, K.; Bouchier, A.; Merrer, P. H.; Llopis, O.; Cibiel, G.

    2011-03-01

    In the microwave domain and among many other advantages, optics represents an elegant solution to increase the quality Q factor in a system. Different types of optical resonators lead to Q factors above 109, and these resonators can be used as an alternative to optical delay lines to set up the frequency in optoelectronic oscillators (OEO). However, microwave-optics is also a complex field, and if the use of optical resonators in high spectral purity frequency generation systems like OEO has been already demonstrated, many aspects of these OEOs are still incompletely understood, especially the contribution to the oscillator phase noise of the different optical and microwave elements used in the oscillator system. In order to improve the phase noise of a fiber ring resonator based OEO, this oscillator has been theoretically studied in term of white frequency noise. In this paper, we present a theoretical study that has lead us to optimize a fiber ring resonator and the experimental phase noise results obtained for an OEO based on an optimized optical resonator. The OEO thermal stability is also investigated in this paper.

  7. Real-Time Detection of Staphylococcus Aureus Using Whispering Gallery Mode Optical Microdisks

    PubMed Central

    Ghali, Hala; Chibli, Hicham; Nadeau, Jay L.; Bianucci, Pablo; Peter, Yves-Alain

    2016-01-01

    Whispering Gallery Mode (WGM) microresonators have recently been studied as a means to achieve real-time label-free detection of biological targets such as virus particles, specific DNA sequences, or proteins. Due to their high quality (Q) factors, WGM resonators can be highly sensitive. A biosensor also needs to be selective, requiring proper functionalization of its surface with the appropriate ligand that will attach the biomolecule of interest. In this paper, WGM microdisks are used as biosensors for detection of Staphylococcus aureus. The microdisks are functionalized with LysK, a phage protein specific for staphylococci at the genus level. A binding event on the surface shifts the resonance peak of the microdisk resonator towards longer wavelengths. This reactive shift can be used to estimate the surface density of bacteria that bind to the surface of the resonator. The limit of detection of a microdisk with a Q-factor around 104 is on the order of 5 pg/mL, corresponding to 20 cells. No binding of Escherichia coli to the resonators is seen, supporting the specificity of the functionalization scheme. PMID:27153099

  8. Low Seismic Attenuation in Southern New England Lithosphere Implies Little Heating by the Upwelling Asthenosphere

    NASA Astrophysics Data System (ADS)

    Lamoureux, J. M.; Menke, W. H.

    2017-12-01

    The Northern Appalachian Anomaly (NAA) is a patch of the asthenosphere in southern New England that is unusually hot given its passive margin setting. Previous research has detected large seismic wave delays that imply a temperature of 770 deg C higher than the mantle below the adjacent craton at the same depth. A key outstanding issue is whether the NAA interacts with the lithosphere above it (e.g. by heating it up). We study this issue using Po and So waves from two magnitude >5.5 earthquakes near the Puerto Rico Trench. These waves, propagating in the cold oceanic lithosphere at near Moho speeds, deliver high frequency energy to the shallow continental lithosphere. We hypothesized that: (1) once within the continental lithosphere, Po and So experience attenuation with distance that can be quantified by a quality factor Q, and that (2) any heating of the lithosphere above the NAA would lead to a higher Q than in regions further north or south along the continental margin. Corresponding Po and So velocities would also be lower. The decay rates of Po and So are estimated using least-squares applied to RMS coda amplitudes measured from digital seismograms from stations in northeastern North America, corrected for instrument response. A roughly log-linear decrease in amplitude is observed, corresponding to P and S wave quality factors in the range of 394-1500 and 727-6847, respectively. Measurements are made for four margin-perpendicular geographical bands, with one band overlapping the NAA. We detect no effect on these amplitudes by the NAA; 95% confidence bounds overlap in every case; Furthermore, all quality factors are much higher than the 100 predicted by lab experiments for near-solidus mantle rocks. These results suggest that the NAA is not causing significant heating of the lithosphere above it. The shear velocities, however, are about 10% slower above the NAA - an effect that may be fossil, reflecting processes that occurred millions of years ago.

  9. Extraction of the neutron magnetic form factor from quasielastic 3He→(e→,e') at Q2=0.1-0.6(GeV/c)2

    NASA Astrophysics Data System (ADS)

    Anderson, B.; Auberbach, L.; Averett, T.; Bertozzi, W.; Black, T.; Calarco, J.; Cardman, L.; Cates, G. D.; Chai, Z. W.; Chen, J. P.; Choi, Seonho; Chudakov, E.; Churchwell, S.; Corrado, G. S.; Crawford, C.; Dale, D.; Deur, A.; Djawotho, P.; Dutta, D.; Finn, J. M.; Gao, H.; Gilman, R.; Glamazdin, A. V.; Glashausser, C.; Glöckle, W.; Golak, J.; Gomez, J.; Gorbenko, V. G.; Hansen, J.-O.; Hersman, F. W.; Higinbotham, D. W.; Holmes, R.; Howell, C. R.; Hughes, E.; Humensky, B.; Incerti, S.; Jager, C. W. De; Jensen, J. S.; Jiang, X.; Jones, C. E.; Jones, M.; Kahl, R.; Kamada, H.; Kievsky, A.; Kominis, I.; Korsch, W.; Kramer, K.; Kumbartzki, G.; Kuss, M.; Lakuriqi, E.; Liang, M.; Liyanage, N.; Lerose, J.; Malov, S.; Margaziotis, D. J.; Martin, J. W.; McCormick, K.; McKeown, R. D.; McIlhany, K.; Meziani, Z.-E.; Michaels, R.; Miller, G. W.; Mitchell, J.; Nanda, S.; Pace, E.; Pavlin, T.; Petratos, G. G.; Pomatsalyuk, R. I.; Pripstein, D.; Prout, D.; Ransome, R. D.; Roblin, Y.; Rvachev, M.; Saha, A.; Salmè, G.; Schnee, M.; Seely, J.; Shin, T.; Slifer, K.; Souder, P. A.; Strauch, S.; Suleiman, R.; Sutter, M.; Tipton, B.; Todor, L.; Viviani, M.; Vlahovic, B.; Watson, J.; Williamson, C. F.; Witała, H.; Wojtsekhowski, B.; Xiong, F.; Xu, W.; Yeh, J.; Żołnierczuk, P.

    2007-03-01

    We have measured the transverse asymmetry AT' in the quasielastic 3He→(e→,e') process with high precision at Q2 values from 0.1 to 0.6(GeV/c)2. The neutron magnetic form factor GMn was extracted at Q2 values of 0.1 and 0.2(GeV/c)2 using a nonrelativistic Faddeev calculation which includes both final-state interactions (FSI) and meson-exchange currents (MEC). Theoretical uncertainties due to the FSI and MEC effects were constrained with a precision measurement of the spin-dependent asymmetry in the threshold region of 3He→(e→,e'). We also extracted the neutron magnetic form factor GMn at Q2 values of 0.3 to 0.6(GeV/c)2 based on plane wave impulse approximation calculations.

  10. Effects of Attenuation of Gas Hydrate-bearing Sediments on Seismic Data: Example from Mallik, Northwest Territories, Canada

    NASA Astrophysics Data System (ADS)

    Bellefleur, G.; Riedel, M.; Brent, T.

    2007-05-01

    Wave attenuation is an important physical property of hydrate-bearing sediments that is rarely taken into account in site characterization with seismic data. We present a field example showing improved images of hydrate- bearing sediments on seismic data after compensation of attenuation effects. Compressional quality factors (Q) are estimated from zero-offset Vertical Seismic Profiling data acquired at Mallik, Northwest Territories, Canada. During the last 10 years, two internationally-partnered research drilling programs have intersected three major intervals of sub-permafrost gas hydrates at Mallik, and have successfully extracted core samples containing significant amount of gas hydrates. Individual gas hydrate intervals are up to 40m in thickness and are characterized by high in situ gas hydrate saturation, sometimes exceeding 80% of pore volume of unconsolidated clastic sediments having average porosities ranging from 25% to 40%. The Q-factors obtained from the VSP data demonstrate significant wave attenuation for permafrost and hydrate- bearing sediments. These results are in agreement with previous attenuation estimates from sonic logs and crosshole data at different frequency intervals. The Q-factors obtained from VSP data were used to compensate attenuation effects on surface 3D seismic data acquired over the Mallik gas hydrate research wells. Intervals of gas hydrate on surface seismic data are characterized by strong reflectivity and effects from attenuation are not perceptible from a simple visual inspection of the data. However, the application of an inverse Q-filter increases the resolution of the data and improves correlation with log data, particularly for the shallowest gas hydrate interval. Compensation of the attenuation effects of the permafrost likely explains most of the improvements for the shallow gas hydrate zone. Our results show that characterization of the Mallik gas hydrates with seismic data not corrected for attenuation would tend to overestimate thicknesses and lateral extent of hydrate-bearing strata and hence, the volume of hydrates in place.

  11. Identification of a novel C1q family member in color crucian carp (Carassius auratus) ovary.

    PubMed

    Chen, Bo; Gui, Jianfang

    2004-07-01

    Potential roles of C1q/tumor necrosis factor (TNF) superfamily proteins have been observed in vertebrate oogenesis and oocyte maturation, but no ovary-specific member has been identified so far. In this study, we have cloned and identified a novel member of C1q family with a C1q domain in the C-terminal from fully grown oocyte cDNA library of color crucian carp and demonstrated that the gene might be specifically expressed in ovary and therefore designated as Carassius auratus ovary-specific C1q-like factor, CaOC1q-like factor. It encodes a 213 amino acid protein with a 17 amino acid signal peptide. There is only one protein band of about 24.5 kDa in the extracts from phase I to phase IV oocytes, but two positive protein bands are detected in the extracts of mature eggs and fertilized eggs. Furthermore, the mobility shift of the smaller target protein band cannot be eliminated by phosphatase treatment, but the larger protein band increases its mobility on the gel after phosphatase treatment, suggesting that the larger protein might be a phosphorylated form. Immunofluorescence localization indicates that the CaOC1q-like proteins localize in cytoplasm, cytoplasm membrane and egg envelope of the oocytes at cortical granule stage and vitellogenesis stage, whereas they were compressed to cytoplasm margin in ovulated mature eggs and discharged into perivitelline space between cytoplasm membrane and egg envelope after egg fertilization. Further studies on distribution and translocation mechanism of the CaOC1q-like factor will be benefit to elucidate the unique function in oogenesis, oocyte maturation and egg fertilization.

  12. Identification of factors for physicians to facilitate early differential diagnosis of scrub typhus, murine typhus, and Q fever from dengue fever in Taiwan.

    PubMed

    Chang, Ko; Lee, Nan-Yao; Ko, Wen-Chien; Tsai, Jih-Jin; Lin, Wei-Ru; Chen, Tun-Chieh; Lu, Po-Liang; Chen, Yen-Hsu

    2017-02-01

    Dengue fever, rickettsial diseases, and Q fever are acute febrile illnesses with similar manifestations in tropical areas. Early differential diagnosis of scrub typhus, murine typhus, and Q fever from dengue fever may be made by understanding the distinguishing clinical characteristics and the significance of demographic and weather factors. We conducted a retrospective study to identify clinical, demographic, and meteorological characteristics of 454 dengue fever, 178 scrub typhus, 143 Q fever, and 81 murine typhus cases in three Taiwan hospitals. Case numbers of murine typhus and Q fever correlated significantly with temperature and rainfall; the scrub typhus case number was only significantly related with temperature. Neither temperature nor rainfall correlated with the case number of dengue fever. The rarity of dengue fever cases from January to June in Taiwan may be a helpful clue for diagnosis in the area. A male predominance was observed, as the male-to-female rate was 2.1 for murine typhus and 7.4 for Q fever. Multivariate analysis revealed the following six important factors for differentiating the rickettsial diseases and Q fever group from the dengue fever group: fever ≥8 days, alanine aminotransferase > aspartate aminotransferase, platelets >63,000/mL, C-reactive protein >31.9 mg/L, absence of bone pain, and absence of a bleeding syndrome. Understanding the rarity of dengue in the first half of a year in Taiwan and the six differentiating factors may help facilitate the early differential diagnosis of rickettsial diseases and Q fever from dengue fever, permitting early antibiotic treatment. Copyright © 2015. Published by Elsevier B.V.

  13. A genome-wide linkage scan for dietary energy and nutrient intakes: the Health, Risk Factors, Exercise Training, and Genetics (HERITAGE) Family Study.

    PubMed

    Collaku, Agron; Rankinen, Tuomo; Rice, Treva; Leon, Arthur S; Rao, D C; Skinner, James S; Wilmore, Jack H; Bouchard, Claude

    2004-05-01

    A poor diet is a risk factor for chronic diseases such as obesity, cardiovascular disease, hypertension, and some cancers. Twin and family studies suggest that genetic factors potentially influence energy and nutrient intakes. We sought to identify genomic regions harboring genes affecting total energy, carbohydrate, protein, and fat intakes. We performed a genomic scan in 347 white sibling pairs and 99 black sibling pairs. Dietary energy and nutrient intakes were assessed by using Willett's food-frequency questionnaire. Single-point and multipoint Haseman-Elston regression techniques were used to test for linkage. These subjects were part of the Health, Risk Factors, Exercise Training, and Genetics (HERITAGE) Family Study, a multicenter project undertaken by 5 laboratories. In the whites, the strongest evidence of linkage appeared for dietary energy and nutrient intakes on chromosomes 1p21.2 (P = 0.0002) and 20q13.13 (P = 0.00007), and that for fat intake appeared on chromosome 12q14.1 (P = 0.0013). The linkage evidence on chromosomes 1 and 20 related to total energy intake rather than to the intake of specific macronutrients. In the blacks, promising linkages for macronutrient intakes occurred on chromosomes 12q23-q24.21, 1q32.1, and 7q11.1. Several potential candidate genes are encoded in and around the linkage regions on chromosomes 1p21.2, 12q14.1, and 20q13.13. These are the first reported human quantitative trait loci for dietary energy and macronutrient intakes. Further study may refine these quantitative trait loci to identify potential candidate genes for energy and specific macronutrient intakes that would be amenable to more detailed molecular studies.

  14. Can coenzyme Q10 supplementation effectively reduce human tumour necrosis factor-α and interleukin-6 levels in chronic diseases? Protocol for a systematic review and meta-analysis of randomised controlled trials.

    PubMed

    Farsi, Farnaz; Heshmati, Javad; Janani, Leila; Irandoost, Pardis; Mesri Alamdari, Naeimeh; Keshtkar, Abbasali; Akbari, Abolfazl; Vafa, Mohammadreza

    2017-10-08

    Inflammation, as a critical factor, can cause numerous chronic diseases by creating various proinflammatory cytokines. Coenzyme Q10 (CoQ10) can potentially exert an anti-inflammatory agent; in turn, this agent can reduce the systemic inflammatory response. The aims of this study are to conduct a comprehensive systematic review and a meta-analysis for the determination of the CoQ10 efficacy on the changes in serum interleukin-6 (IL-6) and the tumour necrosis factor-α (TNF-α) levels in unhealthy subjects. We will conduct an electronic search for articles published between January 1990 and January 2017 using a prespecified search strategy in MEDLINE, SCOPUS, EMBASE, CENTRAL and Web of Science.Our search will focus only on randomised controlled clinical trials in unhealthy subjects that employ either a parallel or a crossover design; this search will involve concurrent control groups. The primary outcomes of the literature are to determine the CoQ10 efficacy on the changes in the serum IL-6 and the TNF-α levels in unhealthy subjects. Secondary outcomes such as body mass index, serum adiponectin and high-sensitivity C-reactive protein levels, lipid profile and the heterogeneity assessment of the primary studies will be evaluated. The stages of screen articles, the extracts of relevant data and the assessment of study quality using the Cochrane risk of bias tool will be conducted independently by the two reviewers. Any disagreement will be resolved by discussion with a third person. If the number of eligible studies is sufficient, we will carry out a meta-analysis according to both outcomes. This study is the protocol for a systematic review and no ethics approval is needed. The findings from the full systematic review will be published in a peer-reviewed journal, and they will also be exhibited at national/international academic and clinical conferences. CRD42016052200. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Coenzyme Q10 and pro-inflammatory markers in children with Down syndrome: clinical and biochemical aspects.

    PubMed

    Zaki, Moushira E; El-Bassyouni, Hala T; Tosson, Angie M S; Youness, Eman; Hussein, Jihan

    Evidence of oxidative stress was reported in individuals with Down syndrome. There is a growing interest in the contribution of the immune system in Down syndrome. The aim of this study is to evaluate the coenzyme Q10 and selected pro-inflammatory markers such as interleukin 6 and tumor necrosis factor α in children with Down syndrome. Eighty-six children (5-8 years of age) were enrolled in this case-control study from two public institutions. At the time of sampling, the patients and controls suffered from no acute or chronic illnesses and received no therapies or supplements. The levels of interleukin 6, tumor necrosis factor α, coenzyme Q10, fasting blood glucose, and intelligence quotient were measured. Forty-three young Down syndrome children and forty-three controls were included over a period of eight months (January-August 2014). Compared with the control group, the Down syndrome patients showed significant increase in interleukin 6 and tumor necrosis factor α (p=0.002), while coenzyme Q10 was significantly decreased (p=0.002). Also, body mass index and fasting blood glucose were significantly increased in patients. There was a significantly positive correlation between coenzyme Q10 and intelligence quotient levels, as well as between interleukin 6 and tumor necrosis factor α. Interleukin 6 and tumor necrosis factor α levels in young children with Down syndrome may be used as biomarkers reflecting the neurodegenerative process in them. Coenzyme Q10 might have a role as a good supplement in young children with Down syndrome to ameliorate the neurological symptoms. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  16. Diagnostic Delay among Adults with Pulmonary Tuberculosis in a High Gross Domestic Product Per Capita Country: Reasons and Magnitude of the Problem.

    PubMed

    Ibrahim, Wanis H; Alousi, Faraj H; Al-Khal, Abdulatif; Bener, Abdulbari; AlSalman, Ahmed; Aamer, Aaiza; Khaled, Ahmed; Raza, Tasleem

    2016-01-01

    To determine the mean and median delays in pulmonary tuberculosis (PTB) diagnosis among adults in one of the world's highest gross domestic product per capita countries and identify patient and health system-related reasons for these delays. This is a cross-sectional, face-to-face, prospective study of 100 subjects with confirmed PTB, conducted at main tuberculosis (TB) admitting facilities in Qatar. The mean and median diagnostic delays were measured. The Chi-square test with two-sided P < 0.05 was considered to determine the association between factors and diagnostic delay. The mean and median total diagnostic delays of PTB were 53 (95% confidence interval [CI] 42.61-63.59) and 30 (interquartile range; Q1-Q3, 15-60) days, respectively. The mean patient factor delay was 45.7 (95% CI 28.1-63.4) days, and the median was 30 (interquartile range; Q1-Q3, 15-60) days. The mean health system factor delay was 46.3 (95% CI 35.46-57.06) days, and the median was 30 (interquartile range; Q1-Q3, 18-60) days. The most common cause of patient factor delay was neglect of TB symptoms by patients (in 39% of cases), and for health-care system factor delay was a failure (mostly at general and private care levels) to suspect PTB by doctors (in 57% of cases). There were no significant associations between the presence of language barrier, patient occupation or nationality, and diagnostic delay. Despite a favorable comparison to other countries, there is a substantial delay in the diagnosis of PTB in Qatar. Relevant actions including health education on TB are required to minimize this delay.

  17. Ferritin Elevation and Improved Responsiveness to Erythropoiesis-Stimulating Agents in Patients on Ferric Citrate Hydrate.

    PubMed

    Yokoyama, Keitaro; Fukagawa, Masafumi; Akiba, Takashi; Nakayama, Masaaki; Otoguro, Toshiya; Yamada, Kana; Nagamine, Yasuo; Fishbane, Steven; Hirakata, Hideki

    2017-05-01

    In hemodialysis patients on ferric citrate hydrate, the increase in ferritin level is mainly due to the administration of the compound. We investigated possible other factors associated with ferritin level and how erythropoietin resistance index and erythropoiesis in those patients were affected. We looked at ferritin-elevating factors using data from a Japanese phase III long-term clinical trial of ferric citrate hydrate. The factors with a strong association with ferritin levels at week 28 were selected by the process of variable selection. In addition, selected factors were analyzed by Mixed Model for Repeated Measurement. Subjects were divided into 3 groups by quantiles (

  18. Enteric coating of soft gelatin capsules by spouted bed: effect of operating conditions on coating efficiency and on product quality.

    PubMed

    Pissinati, Rafael; Oliveira, Wanderley Pereira

    2003-05-01

    The present study was conducted in order to analyze the viability of the spouted bed process for application of a gastric-resistant coating to soft gelatin capsules. The variables investigated were: included angle of conical base, (gamma), the relation between the feed mass flow rate of the coating suspension and the feed mass flow rate of spouting gas (W(s)/W(g)); the ratio between the flow rate of the spouting gas and the flow rate at minimum spouting condition (Q/Q(ms)); the mass of capsules in the bed (M(0)), and the capsule's size. The product quality was measured by disintegration tests, traction x deformation tests, image analysis and by the evaluation of the coating mass distribution and shape factor variation during the coating operation. The experiments were performed in a spouted bed with a column diameter of 200 mm and included a conical base angle of 40 degrees. The best coating efficiency values were obtained for M(0)=300 g. Coating efficiency tended to increase with increasing W(s)/W(g) ratio. Disintegration tests showed that the gastric-resistant effect was obtained with a coating mass of 3.86 mg/cm(2). The shape factor increase during the coating operation. The capsule's coating mass distribution tended to maintain the original distribution.

  19. Experimental evidences for molecular origin of low-Q peak in neutron/x-ray scattering of 1-alkyl-3-methylimidazolium bis(trifluoromethanesulfonyl)amide ionic liquids

    NASA Astrophysics Data System (ADS)

    Fujii, Kenta; Kanzaki, Ryo; Takamuku, Toshiyuki; Kameda, Yasuo; Kohara, Shinji; Kanakubo, Mitsuhiro; Shibayama, Mitsuhiro; Ishiguro, Shin-ichi; Umebayashi, Yasuhiro

    2011-12-01

    Short- and long-range liquid structures of [CnmIm+][TFSA-] with n = 2, 4, 6, 8, 10, and 12 have been studied by high-energy x-ray diffraction (HEXRD) and small-angle neutron scattering (SANS) experiments with the aid of MD simulations. Observed x-ray structure factor, S(Q), for the ionic liquids with the alkyl-chain length n > 6 exhibited a characteristic peak in the low-Q range of 0.2-0.4 Å -1, indicating the heterogeneity of their ionic liquids. SANS profiles IH(Q) and ID(Q) for the normal and the alkyl group deuterated ionic liquids, respectively, showed significant peaks for n = 10 and 12 without no form factor component for large spherical or spheroidal aggregates like micelles in solution. The peaks for n = 10 and 12 evidently disappeared in the difference SANS profiles ΔI(Q) [=ID(Q) - IH(Q)], although that for n = 12 slightly remained. This suggests that the long-range correlations originated from the alkyl groups hardly contribute to the low-Q peak intensity in SANS. To reveal molecular origin of the low-Q peak, we introduce here a new function; x-ray structure factor intensity at a given Q as a function of r, SQpeak(r). The SQpeak(r) function suggests that the observed low-Q peak intensity depending on n is originated from liquid structures at two r-region of 5-8 and 8-15 Å for all ionic liquids examined except for n = 12. Atomistic MD simulations are consistent with the HEXRD and SANS experiments, and then we discussed the relationship between both variations of low-Q peak and real-space structure with lengthening the alkyl group of the CnmIm.

  20. The association between socioeconomic factors and breast cancer-specific survival varies by race.

    PubMed

    Agarwal, Shailesh; Ying, Jian; Boucher, Kenneth M; Agarwal, Jayant P

    2017-01-01

    Although racial disparity is well described for oncologic outcomes, factors associated with survival within racial groups remains unexplored. The objective of this study is to determine whether breast cancer survival among White or Black patients is associated with differing patient factors. Women diagnosed with breast cancer from 1998 through 2012 were identified in the Surveillance, Epidemiology, and End Results (SEER) database. Cox proportional hazard logistic regression was used to estimate cause-specific survival in the combined cohort, and separate cohorts of Black or White patients only. Main outcomes included cause-specific survival in cohorts of Black only, White only, or all patients adjusted for demographic and oncologic factors. A total of 406,907 Black (10.8%) or White (89.2%) patients diagnosed with breast cancer from 1998 through 2012 were isolated. Cancer-specific survival analysis of the combined cohort showed significantly decreased hazard ratio (H.R.) in patients from the higher economic quartiles (Q1: 1.0 (ref), Q2: 0.95 (p<0.01), Q3: 0.94 (p<0.01), Q4: 0.87 (p<0.001)). Analysis of the White only cohort showed a similar relationship with income (Q1: 1.0 (ref), Q2: 0.95 (p<0.01), Q3: 0.95 (p<0.01), Q4: 0.86 (p<0.001)). However, analysis of the Black only cohort did not show a relationship with income (Q1: 1.0 (ref), Q2: 1.04 (p = 0.34), Q3: 0.97 (p = 0.53), Q4: 1.04 (p = 0.47)). A test of interaction confirmed that the association between income and cancer-specific survival is dependent on patient race, both with and without adjustment for demographic and oncologic characteristics (p<0.01). While median county income is positively associated with cancer-specific survival among White patients, this is not the case with Black patients. Similar findings were noted for education level. These findings suggest that the association between socioeconomic status and breast cancer survival commonly reported in the literature is specific to White patients. These findings provide insight into differences between White and Black patients in cancer-specific survival.

  1. Tailoring the High-Q LC Filter Arrays for Readout of Kilo-Pixel TES Arrays in the SPICA-SAFARI Instrument

    NASA Astrophysics Data System (ADS)

    Bruijn, M. P.; Gottardi, L.; den Hartog, R. H.; van der Kuur, J.; van der Linden, A. J.; Jackson, B. D.

    2014-08-01

    Following earlier presentations of arrays of high quality factor (Q 10.000) superconducting resonators in the MHz regime, we report on improvement of the packing density of resonance frequencies to 160 in the 1-3 MHz band. Spread in the spacing of resonances is found to be limited to 1 kHz (1 with the present fabrication procedure. The present packing density of frequencies and chip area approaches the requirements for the SAFARI instrument on the SPICA mission (in preparation). The a-Si:H dielectric layer in the planar S-I-S capacitors shows a presently unexplained apparent negative effective series resistance, depending on operating temperature and applied testing voltage.

  2. Comparison of techniques that use the single scattering model to compute the quality factor Q from coda waves

    USGS Publications Warehouse

    Novelo-Casanova, D. A.; Lee, W.H.K.

    1991-01-01

    Using simulated coda waves, the resolution of the single-scattering model to extract coda Q (Qc) and its power law frequency dependence was tested. The back-scattering model of Aki and Chouet (1975) and the single isotropic-scattering model of Sato (1977) were examined. The results indicate that: (1) The input Qc models are reasonably well approximated by the two methods; (2) almost equal Qc values are recovered when the techniques sample the same coda windows; (3) low Qc models are well estimated in the frequency domain from the early and late part of the coda; and (4) models with high Qc values are more accurately extracted from late code measurements. ?? 1991 Birkha??user Verlag.

  3. Dissipation and traversal time in Josephson junctions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cacciari, Ilaria; Ranfagni, Anedio; Moretti, Paolo

    2010-05-01

    The various ways of evaluating dissipative effects in macroscopic quantum tunneling are re-examined. The results obtained by using functional integration, while confirming those of previously given treatments, enable a comparison with available experimental results relative to Josephson junctions. A criterion based on the shortening of the semiclassical traversal time tau of the barrier with regard to dissipation can be established, according to which DELTAtau/tau > or approx. N/Q, where Q is the quality factor of the junction and N is a numerical constant of order unity. The best agreement with the experiments is obtained for N=1.11, as it results frommore » a semiempirical analysis based on an increase in the potential barrier caused by dissipative effects.« less

  4. Quantification of tidal parameters from Solar System data

    NASA Astrophysics Data System (ADS)

    Lainey, Valéry

    2016-11-01

    Tidal dissipation is the main driver of orbital evolution of natural satellites and a key point to understand the exoplanetary system configurations. Despite its importance, its quantification from observations still remains difficult for most objects of our own Solar System. In this work, we overview the method that has been used to determine, directly from observations, the tidal parameters, with emphasis on the Love number k_2 and the tidal quality factor Q. Up-to-date values of these tidal parameters are summarized. Last, an assessment on the possible determination of the tidal ratio k_2/Q of Uranus and Neptune is done. This may be particularly relevant for coming astrometric campaigns and future space missions focused on these systems.

  5. Reply to "Comment on `Route from discreteness to the continuum for the Tsallis q -entropy' "

    NASA Astrophysics Data System (ADS)

    Oikonomou, Thomas; Bagci, G. Baris

    2018-06-01

    It has been known for some time that the usual q -entropy Sq(n ) cannot be shown to converge to the continuous case. In Phys. Rev. E 97, 012104 (2018), 10.1103/PhysRevE.97.012104, we have shown that the discrete q -entropy S˜q(n ) converges to the continuous case when the total number of states are properly taken into account in terms of a convergence factor. Ou and Abe [previous Comment, Phys. Rev. E 97, 066101 (2018), 10.1103/PhysRevE.97.066101] noted that this form of the discrete q -entropy does not conform to the Shannon-Khinchin expandability axiom. As a reply, we note that the fulfillment or not of the expandability property by the discrete q -entropy strongly depends on the origin of the convergence factor, presenting an example in which S˜q(n ) is expandable.

  6. The effect of safety factor profile on transport in steady-state, high-performance scenarios

    DOE PAGES

    Holcomb, C. T.; Ferron, J. R.; Luce, T. C.; ...

    2012-03-09

    In this study, an analysis of the dependence of transport on the safety factor profile in high-performance, steady-state scenario discharges is presented. This is based on experimental scans of q 95 and q min taken with fixed β N, toroidal field, double-null plasma shape, divertor pumping, and electron cyclotron current drive input. The temperature and thermal diffusivity profiles were found to vary considerably with the q-profile, and these variations were significantly different for electrons and ions. With fixed q 95, both temperature profiles increase and broaden as q min is increased and the magnetic shear becomes low or negative inmore » the inner half radius, but these temperature profile changes are stronger for the electrons. Power balance calculations show the peak in the ion thermal diffusivity (χ i) at ρ – 0.6 – 0.8 increases with q 95 or q min.« less

  7. Refractive index dependence of L3 photonic crystal nano-cavities.

    PubMed

    Adawi, A M; Chalcraft, A R; Whittaker, D M; Lidzey, D G

    2007-10-29

    We model the optical properties of L3 photonic crystal nano-cavities as a function of the photonic crystal membrane refractive index n using a guided mode expansion method. Band structure calculations revealed that a TE-like full band-gap exists for materials of refractive index as low as 1.6. The Q-factor of such cavities showed a super-linear increase with refractive index. By adjusting the relative position of the cavity side holes, the Q-factor was optimised as a function of the photonic crystal membrane refractive index n over the range 1.6 to 3.4. Q-factors in the range 3000-8000 were predicted from absorption free materials in the visible range with refractive index between 2.45 and 2.8.

  8. Probing dynamics of micro-magnets with multi-mode superconducting resonator

    NASA Astrophysics Data System (ADS)

    Golovchanskiy, I. A.; Abramov, N. N.; Stolyarov, V. S.; Shchetinin, I. V.; Dzhumaev, P. S.; Averkin, A. S.; Kozlov, S. N.; Golubov, A. A.; Ryazanov, V. V.; Ustinov, A. V.

    2018-05-01

    In this work, we propose and explore a sensitive technique for investigation of ferromagnetic resonance and corresponding magnetic properties of individual micro-scaled and/or weak ferromagnetic samples. The technique is based on coupling the investigated sample to a high-Q transmission line superconducting resonator, where the response of the sample is studied at eigen frequencies of the resonator. The high quality factor of the resonator enables sensitive detection of weak absorption losses at multiple frequencies of the ferromagnetic resonance. Studying the microwave response of individual micro-scaled permalloy rectangles, we have confirmed the superiority of fluxometric demagnetizing factor over the commonly accepted magnetometric one and have depicted the demagnetization of the sample, as well as magnetostatic standing wave resonance.

  9. Theoretical Significance in Q Methodology: A Qualitative Approach to a Mixed Method

    ERIC Educational Resources Information Center

    Ramlo, Susan

    2015-01-01

    Q methodology (Q) has offered researchers a unique scientific measure of subjectivity since William Stephenson's first article in 1935. Q's focus on subjectivity includes self-referential meaning and interpretation. Q is most often identified with its technique (Q-sort) and its method (factor analysis to group people); yet, it consists of a…

  10. What are the low- Q and large- x boundaries of collinear QCD factorization theorems?

    DOE PAGES

    Moffat, E.; Melnitchouk, W.; Rogers, T. C.; ...

    2017-05-26

    Familiar factorized descriptions of classic QCD processes such as deeply-inelastic scattering (DIS) apply in the limit of very large hard scales, much larger than nonperturbative mass scales and other nonperturbative physical properties like intrinsic transverse momentum. Since many interesting DIS studies occur at kinematic regions where the hard scale,more » $$Q \\sim$$ 1-2 GeV, is not very much greater than the hadron masses involved, and the Bjorken scaling variable $$x_{bj}$$ is large, $$x_{bj} \\gtrsim 0.5$$, it is important to examine the boundaries of the most basic factorization assumptions and assess whether improved starting points are needed. Using an idealized field-theoretic model that contains most of the essential elements that a factorization derivation must confront, we retrace in this paper the steps of factorization approximations and compare with calculations that keep all kinematics exact. We examine the relative importance of such quantities as the target mass, light quark masses, and intrinsic parton transverse momentum, and argue that a careful accounting of parton virtuality is essential for treating power corrections to collinear factorization. Finally, we use our observations to motivate searches for new or enhanced factorization theorems specifically designed to deal with moderately low-$Q$ and large-$$x_{bj}$$ physics.« less

  11. Optical performance of hybrid porous silicon-porous alumina multilayers

    NASA Astrophysics Data System (ADS)

    Cencha, L. G.; Antonio Hernández, C.; Forzani, L.; Urteaga, R.; Koropecki, R. R.

    2018-05-01

    In this work, we study the optical response of structures involving porous silicon and porous alumina in a multi-layered hybrid structure. We performed a rational design of the optimal sequence necessary to produce a high transmission and selective filter, with potential applications in chemical and biosensors. The combination of these porous materials can be used to exploit its distinguishing features, i.e., high transparency of alumina and high refractive index of porous silicon. We assembled hybrid microcavities with a central porous alumina layer between two porous silicon Bragg reflectors. In this way, we constructed a Fabry-Perot resonator with high reflectivity and low absorption that improves the quality of the filter compared to a microcavity built only with porous silicon or porous alumina. We explored a simpler design in which one of the Bragg reflectors is replaced by the aluminium that remains bound to the alumina after its fabrication. We theoretically explored the potential of the proposal and its limitations when considering the roughness of the layers. We found that the quality of a microcavity made entirely with porous silicon shows a limit in the visible range due to light absorption. This limitation is overcome in the hybrid scheme, with the roughness of the layers determining the ultimate quality. Q-factors of 220 are experimentally obtained for microcavities supported on aluminium, while Q-factors around 600 are reached for microcavities with double Bragg reflectors, centred at 560 nm. This represents a four-fold increase with respect to the optimal porous silicon microcavity at this wavelength.

  12. A procedure for the reliability improvement of the oblique ionograms automatic scaling algorithm

    NASA Astrophysics Data System (ADS)

    Ippolito, Alessandro; Scotto, Carlo; Sabbagh, Dario; Sgrigna, Vittorio; Maher, Phillip

    2016-05-01

    A procedure made by the combined use of the Oblique Ionogram Automatic Scaling Algorithm (OIASA) and Autoscala program is presented. Using Martyn's equivalent path theorem, 384 oblique soundings from a high-quality data set have been converted into vertical ionograms and analyzed by Autoscala program. The ionograms pertain to the radio link between Curtin W.A. (CUR) and Alice Springs N.T. (MTE), Australia, geographical coordinates (17.60°S; 123.82°E) and (23.52°S; 133.68°E), respectively. The critical frequency foF2 values extracted from the converted vertical ionograms by Autoscala were then compared with the foF2 values derived from the maximum usable frequencies (MUFs) provided by OIASA. A quality factor Q for the MUF values autoscaled by OIASA has been identified. Q represents the difference between the foF2 value scaled by Autoscala from the converted vertical ionogram and the foF2 value obtained applying the secant law to the MUF provided by OIASA. Using the receiver operating characteristic curve, an appropriate threshold level Qt was chosen for Q to improve the performance of OIASA.

  13. Photonic crystal lasers using wavelength-scale embedded active region

    NASA Astrophysics Data System (ADS)

    Matsuo, Shinji; Sato, Tomonari; Takeda, Koji; Shinya, Akihiko; Nozaki, Kengo; Kuramochi, Eiichi; Taniyama, Hideaki; Notomi, Masaya; Fujii, Takuro; Hasebe, Koichi; Kakitsuka, Takaaki

    2014-01-01

    Lasers with ultra-low operating energy are desired for use in chip-to-chip and on-chip optical interconnects. If we are to reduce the operating energy, we must reduce the active volume. Therefore, a photonic crystal (PhC) laser with a wavelength-scale cavity has attracted a lot of attention because a PhC provides a large Q-factor with a small volume. To improve this device's performance, we employ an embedded active region structure in which the wavelength-scale active region is buried with an InP PhC slab. This structure enables us to achieve effective confinement of both carriers and photons, and to improve the thermal resistance of the device. Thus, we have obtained a large external differential quantum efficiency of 55% and an output power of -10 dBm by optical pumping. For electrical pumping, we use a lateral p-i-n structure that employs Zn diffusion and Si ion implantation for p-type and n-type doping, respectively. We have achieved room-temperature continuous-wave operation with a threshold current of 7.8 µA and a maximum 3 dB bandwidth of 16.2 GHz. The results of an experimental bit error rate measurement with a 10 Gbit s-1 NRZ signal reveal the minimum operating energy for transferring a single bit of 5.5 fJ. These results show the potential of this laser to be used for very short reach interconnects. We also describe the optimal design of cavity quality (Q) factor in terms of achieving a large output power with a low operating energy using a calculation based on rate equations. When we assume an internal absorption loss of 20 cm-1, the optimized coupling Q-factor is 2000.

  14. Interstitial deletion of chromosome 1q [del(1)(q24q25.3)] identified by fluorescence in situ hybridization and gene dosage analysis of apolipoprotein A-II, coagulation factor V, and antithrombin III

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takano, Takako; Yamanouchi, Yasuko; Mori, Yosuke

    We report on a 12-month-old Japanese boy with an interstitial deletion of the long-arm of chromosome 1 and meningomyelocele, hydrocephalus, anal atresia, atrial septal defect, left renal agenesis, bilateral cryptorchidism, talipes equinovarus, low birth weight, growth/developmental retardation, and many minor anomalies. By conventional GTG-banding, his karyotype was first interpreted as 46,XY,de1(1)(q23q24), but it was corrected as 46,XY.ish del(1)(q24q25.3) by fluorescence in situ hybridization using 11 known cosmid clones as probes. His serum levels of apolipoprotein A-II (gene symbol: APOA2, previously assigned to 1q21-q23) and coagulation factor V (F5, 1q21-q25) were normal, while serum concentration and activity of antithrombin III (AT3,more » 1q23-q25.1) was low. The results indicated that localization of APOA2 and F5 are proximal to the deleted region and AT3 is located within the deletion extent in the patient. 16 refs., 4 figs.« less

  15. Polarization observables and T-noninvariance in the weak charged current induced electron proton scattering

    NASA Astrophysics Data System (ADS)

    Fatima, A.; Sajjad Athar, M.; Singh, S. K.

    2018-06-01

    In this work, we have studied the total scattering cross section (σ, differential scattering cross section ( dσ/d Q2) as well as the longitudinal ( P_L(Ee,Q2)), perpendicular ( PP(Ee,Q2)), and transverse ( PT(Ee,Q2)) components of the polarization of the final hadron ( n, Λ and Σ0) produced in the electron proton scattering induced by the weak charged current. We have not assumed T-invariance which allows the transverse component of the hadron polarization perpendicular to the production plane to be non-zero. The numerical results are presented for all the above observables and their dependence on the axial vector form factor and the weak electric form factor are discussed. The present study enables the determination of the axial vector nucleon-hyperon transition form factors at high Q2 in the strangeness sector which can provide a test of the symmetries of the weak hadronic currents like T-invariance and SU(3) symmetry while assuming the hypothesis of conserved vector current and partial conservation of axial vector current.

  16. Attitudes towards rotating shift work in clinical nurses: a Q-methodology study.

    PubMed

    Ha, Eun-Ho

    2015-09-01

    To identify clinical nurses' attitudes towards rotating shift work. Many hospitals worldwide employ rotating shift work patterns to staff their facilities. Attitudes of clinical nurses towards rotating shift work vary. To understand clinical nurses' attitudes towards rotating shift work, Q-methodology, a method for the analysis of subjective viewpoints with the strengths of both qualitative and quantitative methods, was used. Forty-six selected Q-statements from each of the 39 participants were classified into a normal distribution using an 11-point bipolar scale. The collected data were analysed using pc-QUANL program. Three discrete factors emerged as follows: factor I (rotating shift work is frustrating: objectionable perspective), factor II (rotating shift work is satisfactory: constructive perspective) and factor III (rotating shift work is problematic, but necessary: ambivalent perspective). The subjective viewpoints of the three identified factors can be applied in developing various roster designs for nurses engaging in rotating shift work. The findings provide the baseline for nurse leaders in helping nurses adjust and deal with rotating shift work. © 2015 John Wiley & Sons Ltd.

  17. The Effect of Viscous Air Damping on an Optically Actuated Multilayer MoS2 Nanomechanical Resonator Using Fabry-Perot Interference

    PubMed Central

    She, Yumei; Li, Cheng; Lan, Tian; Peng, Xiaobin; Liu, Qianwen; Fan, Shangchun

    2016-01-01

    We demonstrated a multilayer molybdenum disulfide (MoS2) nanomechanical resonator by using optical Fabry-Perot (F-P) interferometric excitation and detection. The thin circular MoS2 nanomembrane with an approximate 8-nm thickness was transferred onto the endface of a ferrule with an inner diameter of 125 μm, which created a low finesse F-P interferometer with a cavity length of 39.92 μm. The effects of temperature and viscous air damping on resonance behavior of the resonator were investigated in the range of −10–80 °C. Along with the optomechanical behavior of the resonator in air, the measured resonance frequencies ranged from 36 kHz to 73 kHz with an extremely low inflection point at 20 °C, which conformed reasonably to those solved by previously obtained thermal expansion coefficients of MoS2. Further, a maximum quality (Q) factor of 1.35 for the resonator was observed at 0 °C due to viscous dissipation, in relation to the lower Knudsen number of 0.0025~0.0034 in the tested temperature range. Moreover, measurements of Q factor revealed little dependence of Q on resonance frequency and temperature. These measurements shed light on the mechanisms behind viscous air damping in MoS2, graphene, and other 2D resonators. PMID:28335290

  18. Compact rf polarizer and its application to pulse compression systems

    DOE PAGES

    Franzi, Matthew; Wang, Juwen; Dolgashev, Valery; ...

    2016-06-01

    We present a novel method of reducing the footprint and increasing the efficiency of the modern multi-MW rf pulse compressor. This system utilizes a high power rf polarizer to couple two circular waveguide modes in quadrature to a single resonant cavity in order to replicate the response of a traditional two cavity configuration using a 4-port hybrid. The 11.424 GHz, high-Q, spherical cavity has a 5.875 cm radius and is fed by the circularly polarized signal to simultaneously excite the degenerate TE 114 modes. The overcoupled spherical cavity has a Q 0 of 9.4×10 4 and coupling factor (β) ofmore » 7.69 thus providing a loaded quality factor Q L of 1.06×10 4 with a fill time of 150 ns. Cold tests of the polarizer demonstrated good agreement with the numerical design, showing transmission of -0.05 dB and reflection back to the input rectangular WR 90 waveguide less than -40 dB over a 100 MHz bandwidth. This novel rf pulse compressor was tested at SLAC using XL-4 Klystron that provided rf power up to 32 MW and generated peak output power of 205 MW and an average of 135 MW over the discharged signal. A general network analysis of the polarizer is discussed as well as the design and high power test of the rf pulse compressor.« less

  19. Insatiable insecurity: maternal obesity as a risk factor for mother-child attachment and child weight.

    PubMed

    Keitel-Korndörfer, Anja; Sierau, Susan; Klein, Annette M; Bergmann, Sarah; Grube, Matthias; von Klitzing, Kai

    2015-01-01

    Childhood obesity has become a rising health problem, and because parental obesity is a basic risk factor for childhood obesity, biological factors have been especially considered in the complex etiology. Aspects of the family interaction, e.g., mother-child attachment, have not been the main focus. Our study tried to fill this gap by investigating whether there is a difference between children of obese and normal weight mothers in terms of mother-child attachment, and whether mother-child attachment predicts child's weight, in a sample of 31 obese and 31 normal weight mothers with children aged 19 to 58 months. Mother-child attachment was measured with the Attachment Q-Set. We found that (1) children of obese mothers showed a lower quality of mother-child attachment than children of normal weight mothers, which indicates that they are less likely to use their mothers as a secure base; (2) the attachment quality predicted child`s BMI percentile; and (3) the mother-child attachment adds incremental validity to the prediction of child's BMI beyond biological parameters (child's BMI birth percentile, BMI of the parents) and mother's relationship status. Implications of our findings are discussed.

  20. Microstrip resonators for electron paramagnetic resonance experiments.

    PubMed

    Torrezan, A C; Mayer Alegre, T P; Medeiros-Ribeiro, G

    2009-07-01

    In this article we evaluate the performance of an electron paramagnetic resonance (EPR) setup using a microstrip resonator (MR). The design and characterization of the resonator are described and parameters of importance to EPR and spin manipulation are examined, including cavity quality factor, filling factor, and microwave magnetic field in the sample region. Simulated microwave electric and magnetic field distributions in the resonator are also presented and compared with qualitative measurements of the field distribution obtained by a perturbation technique. Based on EPR experiments carried out with a standard marker at room temperature and a MR resonating at 8.17 GHz, the minimum detectable number of spins was found to be 5 x 10(10) spins/GHz(1/2) despite the low MR unloaded quality factor Q0=60. The functionality of the EPR setup was further evaluated at low temperature, where the spin resonance of Cr dopants present in a GaAs wafer was detected at 2.3 K. The design and characterization of a more versatile MR targeting an improved EPR sensitivity and featuring an integrated biasing circuit for the study of samples that require an electrical contact are also discussed.

  1. Q and you: The application of Q methodology in recreation research

    Treesearch

    Whitney Ward

    2010-01-01

    Researchers have used various qualitative and quantitative methods to deal with subjectivity in studying people's recreation experiences. Q methodology has been the most effective approach for analyzing both qualitative and quantitative aspects of experience, including attitudes or perceptions. The method is composed of two main components--Q sorting and Q factor...

  2. Ultra-compact air-mode photonic crystal nanobeam cavity integrated with bandstop filter for refractive index sensing.

    PubMed

    Sun, Fujun; Fu, Zhongyuan; Wang, Chunhong; Ding, Zhaoxiang; Wang, Chao; Tian, Huiping

    2017-05-20

    We propose and investigate an ultra-compact air-mode photonic crystal nanobeam cavity (PCNC) with an ultra-high quality factor-to-mode volume ratio (Q/V) by quadratically tapering the lattice space of the rectangular holes from the center to both ends while other parameters remain unchanged. By using the three-dimensional finite-difference time-domain method, an optimized geometry yields a Q of 7.2×10 6 and a V∼1.095(λ/n Si ) 3 in simulations, resulting in an ultra-high Q/V ratio of about 6.5×10 6 (λ/n Si ) -3 . When the number of holes on either side is 8, the cavity possesses a high sensitivity of 252 nm/RIU (refractive index unit), a high calculated Q-factor of 1.27×10 5 , and an ultra-small effective V of ∼0.758(λ/n Si ) 3 at the fundamental resonant wavelength of 1521.74 nm. Particularly, the footprint is only about 8×0.7  μm 2 . However, inevitably our proposed PCNC has several higher-order resonant modes in the transmission spectrum, which makes the PCNC difficult to be used for multiplexed sensing. Thus, a well-designed bandstop filter with weak sidelobes and broad bandwidth based on a photonic crystal nanobeam waveguide is created to connect with the PCNC to filter out the high-order modes. Therefore, the integrated structure presented in this work is promising for building ultra-compact lab-on-chip sensor arrays with high density and parallel-multiplexing capability.

  3. Comparing the content of leadership theories and managers' shared perceptions of effective leadership: a Q-method study of trainee managers in the English NHS.

    PubMed

    Freeman, Tim

    2013-08-01

    Health service managers face potential conflicts between corporate and professional agendas, a tension sharpened for trainees by their junior status and relative inexperience. While academic leadership theory forms an integral part of contemporary management development programmes, relatively little is known of trainees' patterned subjectivities in relation to leadership theories. The objective of this study was to explore such subjectivities within a cohort of trainees on the National Health Service Graduate Management Training Scheme (NHS GMTS), a 'fast-track' programme which prepares graduate entrants for director-level health service management posts. A Q-method design was used and four shared subjectivities were identified: leadership as collaborative social process ('relational'); leadership as integrity ('moral'); leadership as effective support of subordinates ('team'); and leadership as construction of a credible leadership persona ('identity'). While the factors broadly map onto competencies indicated within the NHS Leadership Qualities Framework which underpin assessments of performance for this student group, it is important not to overstate the governance effect of the assessment regime. Rather, factors reflect tensions between required competencies, namely the mobilisation of diverse interest groups, the ethical base of decisions and the identity work required to convince others of leadership status. Indeed, factor 2 ('moral') effectively defines leadership as the embodiment of public service ethos. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  4. Validation of eating disorders examination questionnaire in Mexican women.

    PubMed

    Unikel Santoncini, Claudia; Bojorquez Chapela, Ietza; Díaz de León Vázquez, Concepción; Vázquez Velázquez, Verónica; Rivera Márquez, José Alberto; Galván Sánchez, Griselda; Rocha Velis, Ingrid

    2018-02-01

    Efficient assessment of eating disorders (ED) is indispensable for research and clinical practice in Mexico. One of the most commonly used questionnaires, the EDE-Q, has a self-applicable questionnaire format with 28 questions and four subscales drawn from the Eating Disorder Examination (EDE), a semistructured interview developed to evaluate the specific symptomatology of eating disorders. Obtain the factorial structure and construct validity of the EDE-Q questionnaire in Mexican women. The language in the EDE-Q was adapted. It was applied to university students (N = 330) and a sample of patients with ED (N = 165) from two ED outpatient treatment services. The anthropometric data of the participants was obtained. Internal consistency was explored using the Cronbach's Alpha coefficient and a confirmatory factor analysis was conducted by group. Cronbach's alpha was 0.9 for the full scale in all groups, while the reliability of each of the subscales fluctuated between 0.8 and 0.9. Confirmatory factor analysis showed that the fit of the seven-item model in three factors was better than that of the original 22-item one and that of the eight-item model for one factor. This study provides information supporting the seven-item and three-factor version, rather than the original or eight-item versions of the EDE-Q. In the future, the adapted version of the EDE-Q will make it possible to draw comparisons between Mexican samples in other socio-cultural contexts. Future research is required to continue refining the instruments to achieve more representative results from the general ED population. © 2018 Wiley Periodicals, Inc.

  5. 3D Coda Attenuation Tomography of Acoustic Emission Data from Laboratory Samples as a tool for imaging pre-failure deformation mechanisms

    NASA Astrophysics Data System (ADS)

    Vinciguerra, S.; King, T. I.; Benson, P. M.; De Siena, L.

    2017-12-01

    In recent years, 3D and 4D seismic tomography have unraveled medium changes during the seismic cycle or before eruptive events. As our resolving power increases, however, complex structures increasingly affect images. Being able to interpret and understand these features requires a multi-discipline approach combining different methods, each sensitive to particular properties of the sub-surface. Rock deformation laboratory experiments can relate seismic properties to the evolving medium quantitatively. Here, an array of 1 MHz Piezo-Electric Transducers has recorded high-quality low-noise acoustic emission (AE) data during triaxial compressional experiments. Samples of Carrara Marble, Darley Dale Sandstone and Westerly Granite were deformed in saturated conditions representative of a depth of about 1 km until brittle failure. Using a time window around sample failure, AE data were filtered between 5 and 75 KHz and processed using a 3D P-coda attenuation-tomography method. Ratios of P-direct to P-coda energies calculated for each source-receiver path were inverted using the coda normalisation method for values of Q (P-wave quality factor). The results show Q-variation with respect to an average Q. Q is a combination of the effects of scattering attenuation (Qs) and intrinsic attenuation Q (Qi), which can be correlated to the sample structure. Qs primary controls energy dissipation in the presence at acoustic impedance (AI) surfaces and at fracture tips, independently of rock type, while pore fluid effects dissipate energy (Qi). Damaged zones appear as high-Q and low-Q anomalies in unsaturated and saturated samples, respectively. We have attributed frequency-dependent high-Q to resonance in the presence of AI surfaces. Low Q areas appear behind AI surfaces and are interpreted as energy shadows. These shadows can affect attenuation tomography imaging at field scale.

  6. Optical gas monitor

    DOEpatents

    Wu, Sheng; Deev, Andrei; Palm, Steve L.; Tang, Yongchun; Goddard, William A.

    2010-11-30

    A frequency modulated spectroscopy system, including a photo-detector, a band-pass filter to filter the output of the photo-detector, and a rectifier to demodulate. The band-pass filter has a relatively high Q factor. With the high Q factor band-pass filter and rectifier, a reference sinusoid is not required for demodulation, resulting in phase-insensitive spectroscopy. Other embodiments are described and claimed.

  7. Optically-controlled extinction ratio and Q-factor tunable silicon microring resonators based on optical forces

    NASA Astrophysics Data System (ADS)

    Long, Yun; Wang, Jian

    2014-06-01

    Tunability is a desirable property of microring resonators to facilitate superior performance. Using light to control light, we present an alternative simple approach to tuning the extinction ratio (ER) and Q-factor of silicon microring resonators based on optical forces. We design an opto-mechanical tunable silicon microring resonator consisting of an add-drop microring resonator and a control-light-carrying waveguide (``controlling'' waveguide). One of the two bus waveguides of the microring resonator is a deformable nanostring put in parallel with the ``controlling'' waveguide. The tuning mechanism relies on the optical force induced deflection of suspended nanostring, leading to the change of coupling coefficient of microring and resultant tuning of ER and Q-factor. Two possible geometries, i.e. double-clamped nanostring and cantilever nanostring, are studied in detail for comparison. The obtained results imply a favorable structure with the microring positioned at the end of the cantilever nanostring. It features a wide tuning range of ER from 5.6 to 39.9 dB and Q-factor from 309 to 639 as changing the control power from 0 to 1.4 mW.

  8. Q-factor control of multilayer micromembrane using PZT composite material

    NASA Astrophysics Data System (ADS)

    Čekas, Elingas; Janušas, Giedrius; Palevicius, Arvydas; Janušas, Tomas; Ciganas, Justas

    2018-02-01

    Cantilever and membrane based sensors, which are capable of providing accurate detection of target analytes have been always an important research topic of medical diagnostics, food testing, and environmental monitoring fields. Here, the mechanical detection is achieved by micro- and nano-scale cantilevers for stress sensing and mass sensing, or micro- and nano-scale plates or membranes. High sensitivity is a major issue for the active element and it could be achieved via increased Q-factor. The ability to control the Q factor expands the range of application of the device and allows to achieve more accurate results. The aim of this paper is to investigate the mechanical and electrical properties, as well as, the ability to control the Q factor of the membrane with PZT nanocomposite. This multilayered membrane was formatted using the n-type <100> silicon substrate by implementing the Low Pressure Chemical Vapor Deposition (LPCVD), photolithography by using photomask with defined dimensions, deep etching, and e-beam evaporation techniques. Dynamic and electrical characteristics of the membrane were numerically investigated using COMSOL Multiphysics software. The use of the multilayered membrane can range from simple monitoring of particles concentration in a closed environment to inspecting glucose levels in human fluids (blood, tears, sweat, etc.).

  9. Engaging hard to engage clients: a Q methodological study involving clinical psychologists.

    PubMed

    Lister, Matthew; Gardner, Damian

    2006-09-01

    This research uses Q methodology to collate a number of techniques, and to investigate what techniques are used to encourage engagement across a number of clinical psychology specialities. Eleven groups of participants from different clinical specialities were interviewed in order to develop a set of 51 statements reflecting engagement techniques that clinicians felt that they were likely to use with 'hard to engage' clients. Seventy-five participants from a similar range of specialities were then asked to Q sort these statements and provide other demographic information. Forty-four participants returned completed Q sorts which were factor analysed by a tailored program (PQ Method) to investigate how the statements fall into patterns that reflect ways clinicians approach engagement. Varimax rotation produced five factors, four of which were able to be interpreted by participant information and comments. These accounts were taken back to some of the initial participants for 'reflexive correction' (Stainton Rogers, 1995). The four factor patterns are discussed in relation to existing literature and the research questions. These identified factors are: (i) the client focused approach; (ii) the interpersonal professional; (iii) the 'eclectic' or systemic approach; (iv) the expert listener. The implications for training, clinical practice and research are discussed.

  10. Individual patient's preferences for hypertension management: a Q-methodological approach.

    PubMed

    Morecroft, Charles; Cantrill, Judy; Tully, Mary P

    2006-06-01

    To systematically explore and elicit individual patient's preferences in the management of their hypertension using Q-methodology. Using Q-methodology, 120 patients ranking 42 statements according to their agreement or disagreement when considering appropriate hypertension management. The statements were derived from an earlier qualitative study. Factor analysis of the data was undertaken using PQMethod software to determine if any patterns were discernible. Ninety-two patients clustered to five factors, which all varied in the degree of involvement patients had, or wished to have, in their hypertension management. The 42 patients who loaded to factor 1 considered that appropriate antihypertensive treatment involved leaving medical decisions to their GPs and trusting their judgement in such matters. The patients (n = 31) who positively loaded to factor 2 suggested that an autonomous relationship with their healthcare professional(s) was an important issue when considering treatment. It is concluded that this study has successfully used Q-methodology to systematically investigate people's subjectivity and developed a novel approach to elicit the views of individual patients, as well as explore and differentiate between groups of patients. The formation of true partnerships between patients and healthcare professionals which will enhance individual patients' ability to self-manage chronic disease.

  11. Febrile patients admitted to remote hospitals in Northeastern Kenya: seroprevalence, risk factors and a clinical prediction tool for Q-Fever.

    PubMed

    Njeru, J; Henning, K; Pletz, M W; Heller, R; Forstner, C; Kariuki, S; Fèvre, E M; Neubauer, H

    2016-06-03

    Q fever in Kenya is poorly reported and its surveillance is highly neglected. Standard empiric treatment for febrile patients admitted to hospitals is antimalarials or penicillin-based antibiotics, which have no activity against Coxiella burnetii. This study aimed to assess the seroprevalence and the predisposing risk factors for Q fever infection in febrile patients from a pastoralist population, and derive a model for clinical prediction of febrile patients with acute Q fever. Epidemiological and clinical data were obtained from 1067 patients from Northeastern Kenya and their sera tested for IgG antibodies against Coxiella burnetii antigens by enzyme-linked-immunosorbent assay (ELISA), indirect immunofluorescence assay (IFA) and quantitative real-time PCR (qPCR). Logit models were built for risk factor analysis, and diagnostic prediction score generated and validated in two separate cohorts of patients. Overall 204 (19.1 %, 95 % CI: 16.8-21.6) sera were positive for IgG antibodies against phase I and/or phase II antigens or Coxiella burnetii IS1111 by qPCR. Acute Q fever was established in 173 (16.2 %, 95 % CI: 14.1-18.7) patients. Q fever was not suspected by the treating clinicians in any of those patients, instead working diagnosis was fever of unknown origin or common tropical fevers. Exposure to cattle (adjusted odds ratio [aOR]: 2.09, 95 % CI: 1.73-5.98), goats (aOR: 3.74, 95 % CI: 2.52-9.40), and animal slaughter (aOR: 1.78, 95 % CI: 1.09-2.91) were significant risk factors. Consumption of unpasteurized cattle milk (aOR: 2.49, 95 % CI: 1.48-4.21) and locally fermented milk products (aOR: 1.66, 95 % CI: 1.19-4.37) were dietary factors associated with seropositivity. Based on regression coefficients, we calculated a diagnostic score with a sensitivity 93.1 % and specificity 76.1 % at cut off value of 2.90: fever >14 days (+3.6), abdominal pain (+0.8), respiratory tract infection (+1.0) and diarrhoea (-1.1). Q fever is common in febrile Kenyan patients but underappreciated as a cause of community-acquired febrile illness. The utility of Q fever score and screening patients for the risky social-economic and dietary practices can provide a valuable tool to clinicians in identifying patients to strongly consider for detailed Q fever investigation and follow up on admission, and making therapeutic decisions.

  12. Ultra-high Q terahertz whispering-gallery modes in a silicon resonator

    NASA Astrophysics Data System (ADS)

    Vogt, Dominik Walter; Leonhardt, Rainer

    2018-05-01

    We report on the first experimental demonstration of terahertz (THz) whispering-gallery modes (WGMs) with an ultra-high quality factor of 1.5 × 104 at 0.62 THz. The WGMs are observed in a high resistivity float zone silicon spherical resonator coupled to a sub-wavelength silica waveguide. A detailed analysis of the coherent continuous wave THz spectroscopy measurements combined with a numerical model based on Mie-Debye-Aden-Kerker theory allows us to unambiguously identify the observed higher order radial THz WGMs.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wasner, Evan; Bearden, Sean; Žutić, Igor, E-mail: zigor@buffalo.edu

    Digital operation of lasers with injected spin-polarized carriers provides an improved operation over their conventional counterparts with spin-unpolarized carriers. Such spin-lasers can attain much higher bit rates, crucial for optical communication systems. The overall quality of a digital signal in these two types of lasers is compared using eye diagrams and quantified by improved Q-factors and bit-error-rates in spin-lasers. Surprisingly, an optimal performance of spin-lasers requires finite, not infinite, spin-relaxation times, giving a guidance for the design of future spin-lasers.

  14. Design aspects and comparison between high Tc superconducting coplanar waveguide and microstrip line

    NASA Technical Reports Server (NTRS)

    Kong, K. S.; Bhasin, K. B.; Itoh, T.

    1991-01-01

    The high T sub c superconducting microstrip line and coplanar waveguide are compared in terms of the loss characteristics and the design aspects. The quality factor Q values for each structure are compared in respect to the same characteristic impedance with the comparable dimensions of the center conductor of the coplanar waveguide and the strip of the microstrip line. Also, the advantages and disadvantages for each structure are discussed in respect to passive microwave circuit applications.

  15. Low edge safety factor operation and passive disruption avoidance in current carrying plasmas by the addition of stellarator rotational transform

    NASA Astrophysics Data System (ADS)

    Pandya, M. D.; ArchMiller, M. C.; Cianciosa, M. R.; Ennis, D. A.; Hanson, J. D.; Hartwell, G. J.; Hebert, J. D.; Herfindal, J. L.; Knowlton, S. F.; Ma, X.; Massidda, S.; Maurer, D. A.; Roberds, N. A.; Traverso, P. J.

    2015-11-01

    Low edge safety factor operation at a value less than two ( q (a )=1 /ι̷tot(a )<2 ) is routine on the Compact Toroidal Hybrid device with the addition of sufficient external rotational transform. Presently, the operational space of this current carrying stellarator extends down to q (a )=1.2 without significant n = 1 kink mode activity after the initial plasma current rise phase of the discharge. The disruption dynamics of these low edge safety factor plasmas depend upon the fraction of helical field rotational transform from external stellarator coils to that generated by the plasma current. We observe that with approximately 10% of the total rotational transform supplied by the stellarator coils, low edge q disruptions are passively suppressed and avoided even though q(a) < 2. When the plasma does disrupt, the instability precursors measured and implicated as the cause are internal tearing modes with poloidal, m, and toroidal, n, helical mode numbers of m /n =3 /2 and 4/3 observed on external magnetic sensors and m /n =1 /1 activity observed on core soft x-ray emissivity measurements. Even though the edge safety factor passes through and becomes much less than q(a) < 2, external n = 1 kink mode activity does not appear to play a significant role in the disruption phenomenology observed.

  16. A Mapping Model for Magnetic Fields with q-profile Variations Typical of Internal Transport Barrier Experiments

    NASA Astrophysics Data System (ADS)

    Rapoport, B. I.; Pavlenko, I.; Weyssow, B.; Carati, D.

    2002-11-01

    Recent studies of ion and electron transport indicate that the safety factor profile, q(r), affects internal transport barrier (ITB) formation in magnetic confinement devices [1, 2]. These studies are consistent with experimental observations that low shear suppresses magnetic island interaction and associated stochasticity when the ITB is formed [3]. In this sense the position and quality of the ITB depend on the stochasticity of the magnetic field, and can be controlled by q(r). This study explores effects of the q-profile on magnetic field stochasticity using two-dimensional mapping techniques. Q-profiles typical of ITB experiments are incorporated into Hamiltonian maps to investigate the relation between magnetic field stochasticity and ITB parameters predicted by other models. It is shown that the mapping technique generates results consistent with these predictions, and suggested that Hamiltonian mappings can be useful as simple and computationally inexpensive approximation methods for describing the magnetic field in ITB experiments. 1. I. Voitsekhovitch et al. 29th EPS Conference on Plasma Physics and Controlled Fusion (2002). O-4.04. 2. G.M.D. Hogeweij et al. Nucl. Fusion. 38 (1998): 1881. 3. K.A. Razumova et al. Plasma Phys. Contr. Fusion. 42 (2000): 973.

  17. qDIET: toward an automated, self-sustaining knowledge base to facilitate linking point-of-sale grocery items to nutritional content

    PubMed Central

    Chidambaram, Valliammai; Brewster, Philip J.; Jordan, Kristine C.; Hurdle, John F.

    2013-01-01

    The United States, indeed the world, struggles with a serious obesity epidemic. The costs of this epidemic in terms of healthcare dollar expenditures and human morbidity/mortality are staggering. Surprisingly, clinicians are ill-equipped in general to advise patients on effective, longitudinal weight loss strategies. We argue that one factor hindering clinicians and patients in effective shared decision-making about weight loss is the absence of a metric that can be reasoned about and monitored over time, as clinicians do routinely with, say, serum lipid levels or HgA1C. We propose that a dietary quality measure championed by the USDA and NCI, the HEI-2005/2010, is an ideal metric for this purpose. We describe a new tool, the quality Dietary Information Extraction Tool (qDIET), which is a step toward an automated, self-sustaining process that can link retail grocery purchase data to the appropriate USDA databases to permit the calculation of the HEI-2005/2010. PMID:24551333

  18. qDIET: toward an automated, self-sustaining knowledge base to facilitate linking point-of-sale grocery items to nutritional content.

    PubMed

    Chidambaram, Valliammai; Brewster, Philip J; Jordan, Kristine C; Hurdle, John F

    2013-01-01

    The United States, indeed the world, struggles with a serious obesity epidemic. The costs of this epidemic in terms of healthcare dollar expenditures and human morbidity/mortality are staggering. Surprisingly, clinicians are ill-equipped in general to advise patients on effective, longitudinal weight loss strategies. We argue that one factor hindering clinicians and patients in effective shared decision-making about weight loss is the absence of a metric that can be reasoned about and monitored over time, as clinicians do routinely with, say, serum lipid levels or HgA1C. We propose that a dietary quality measure championed by the USDA and NCI, the HEI-2005/2010, is an ideal metric for this purpose. We describe a new tool, the quality Dietary Information Extraction Tool (qDIET), which is a step toward an automated, self-sustaining process that can link retail grocery purchase data to the appropriate USDA databases to permit the calculation of the HEI-2005/2010.

  19. Increased risk for CRC in diabetic patients with the nonrisk allele of SNPs at 8q24.

    PubMed

    Ishimaru, Shinya; Mimori, Koshi; Yamamoto, Ken; Inoue, Hiroshi; Imoto, Seiya; Kawano, Shuichi; Yamaguchi, Rui; Sato, Tetsuya; Toh, Hiroyuki; Iinuma, Hisae; Maeda, Toyoki; Ishii, Hideshi; Suzuki, Sadao; Tokudome, Shinkan; Watanabe, Masahiko; Tanaka, Jun-ichi; Kudo, Shin-ei; Sugihara, Ken-ichi; Hase, Kazuo; Mochizuki, Hidetaka; Kusunoki, Masato; Yamada, Kazutaka; Shimada, Yasuhiro; Moriya, Yoshihiro; Barnard, Graham F; Miyano, Satoru; Mori, Masaki

    2012-09-01

    Colorectal cancer (CRC) oncogenesis was considered to be determined by interactions between genetic and environmental factors. Specific interacting factors that influence CRC morbidity have yet to be fully investigated. A multi-institutional collaborative study with 1511 CRC patients and 2098 control subjects was used to compare the odds ratios for the occurrence of polymorphisms at 11 known single nucleotide polymorphisms (SNPs). TaqMan PCR and questionnaires were used to evaluate the effects of environmental exposures. Variants of rs6983267 on 8q24 were the most significant markers of risk for CRC (odds ratio 1.16, 95% confidence interval 1.06-1.27, P = 0.0015). Non-insulin-dependent diabetes mellitus (DM), a higher body mass index at age 20, and meat consumption were environmental risk factors, whereas a tuna-rich diet and vitamin intake were protective factors. The cohort of rs6983267 SNP major (T) allele at 8q24 and DM had a 1.66-fold higher risk ratio than the cohort of major allele patients without DM. We confirmed that interactions between the genetic background and environmental factors are associated with increased risk for CRC. There is a robust risk of the minor G allele at the 8q24 rs6983267 SNP; however, a major T allele SNP could more clearly reveal a correlation with CRC specifically when DM is present.

  20. Frequency-dependent Lg Q within the continental United States

    USGS Publications Warehouse

    Erickson, D.; McNamara, D.E.; Benz, H.M.

    2004-01-01

    Frequency-dependent crustal attenuation (1/Q) is determined for seven distinct physiographic/tectonic regions of the continental United States using high-quality Lg waveforms recorded on broadband stations in the frequency band 0.5 to 16 Hz. Lg attenuation is determined from time-domain amplitude measurements in one-octave frequency bands centered on the frequencies 0.75, 1.0, 3.0, 6.0, and 12.0 Hz. Modeling errors are determined using a delete-j jackknife resampling technique. The frequency-dependent quality factor is modeled in the form of Q = Q0 fη. Regions were initially selected based on tectonic provinces but were eventually limited and adjusted to maximize ray path coverage in each area. Earthquake data was recorded on several different networks and constrained to events occurring within the crust (<40 km depth) and at least mb 3.5 in size. A singular value decomposition inversion technique was applied to the data to simultaneously solve for source and receiver terms along with Q for each region at specific frequencies. The lowest crustal Q was observed in northern and southern California where Q is described by the functions Q = 152(±37)f0.72(±0.16) and Q = 105(±26)f0.67(±0.16), respectively. The Basin and Range Province, Pacific Northwest, and Rocky Mountain states also display lower Q and a strong frequency dependence characterized by the functions Q = 200(±40)f0.68(±0.12), Q = 152(±49)f0.76(±0.18), and Q = 166(±37)f0.61(±0.14), respectively. In contrast, in the central and northeast United States Q functions are Q = 640(±225)f0.344(±0.22) and Q = 650(±143)f0.36(±0.14), respectively, show a high crustal Q and a weaker frequency dependence. These results improve upon previous Lg modeling by subdividing the United States into smaller, distinct tectonic regions and using significantly more data that provide improved constraints on frequency-dependent attenuation and errors. A detailed attenuation map of the continental United States can provide significant input into hazard map mitigation. Both scattering and intrinsic attenuation mechanisms are likely to play a comparable role in the frequency range considered in the study.

  1. Identification of two key genes controlling chill haze stability of beer in barley (Hordeum vulgare L).

    PubMed

    Ye, Lingzhen; Huang, Yuqing; Dai, Fei; Ning, Huajiang; Li, Chengdao; Zhou, Meixue; Zhang, Guoping

    2015-06-11

    In bright beer, haze formation is a serious quality problem, degrading beer quality and reducing its shelf life. The quality of barley (Hordeum vulgare L) malt, as the main raw material for beer brewing, largely affects the colloidal stability of beer. In this study, the genetic mechanism of the factors affecting beer haze stability in barley was studied. Quantitative trait loci (QTL) analysis of alcohol chill haze (ACH) in beer was carried out using a Franklin/Yerong double haploid (DH) population. One QTL, named as qACH, was detected for ACH, and it was located on the position of about 108 cM in chromosome 4H and can explain about 20 % of the phenotypic variation. Two key haze active proteins, BATI-CMb and BATI-CMd were identified by proteomics analysis. Bioinformatics analysis showed that BATI-CMb and BATI-CMd had the same position as qACH in the chromosome. It may be deduced that BATI-CMb and BATI-CMd are candidate genes for qACH, controlling colloidal stability of beer. Polymorphism comparison between Yerong and Franklin in the nucleotide and amino acid sequence of BATI-CMb and BATI-CMd detected the corresponding gene specific markers, which could be used in marker-assisted selection for malt barley breeding. We identified a novel QTL, qACH controlling chill haze of beer, and two key haze active proteins, BATI-CMb and BATI-CMd. And further analysis showed that BATI-CMb and BATI-CMd might be the candidate genes associated with beer chill haze.

  2. Childhood Precursors of the Narcissistic Personality.

    PubMed

    Cramer, Phebe

    2017-09-01

    This research identifies the childhood personality characteristics that predict the presence of narcissism in adulthood. Using data from the longitudinal study of Block and Block (The California Child Q-set. Palo Alto, CA: Consulting Psychologists Press, 1980), childhood personality characteristics were assessed at age 11 (N = 100) using the California Child Q-set. A number of these were shown to differentially predict the presence of grandiose or vulnerable narcissism at age 23. Factor analyses of the Child Q-set items showed that the presence of Grandiose Narcissism was positively related to childhood factors representing social presence and negatively related to planfulness. In contrast, vulnerable narcissism was positively related to childhood impulsivity and negatively related to stable self-esteem. Both types of narcissism were positively related to childhood factors representing need for control.

  3. Quality transitivity and traceability system of herbal medicine products based on quality markers.

    PubMed

    Liu, Changxiao; Guo, De-An; Liu, Liang

    2018-05-15

    Due to a variety of factors to affect the herb quality, the existing quality management model is unable to evaluate the process control. The development of the concept of "quality marker" (Q-marker) lays basis for establishing an independent process quality control system for herbal products. To ensure the highest degree of safety, effectiveness and quality process control of herbal products, it is aimed to establish a quality transitivity and traceability system of quality and process control from raw materials to finished herbal products. Based on the key issues and challenges of quality assessment, the current status of quality and process controls from raw materials to herbal medicinal products listed in Pharmacopoeia were analyzed and the research models including discovery and identification of Q-markers, analysis and quality management of risk evaluation were designed. Authors introduced a few new technologies and methodologies, such as DNA barcoding, chromatographic technologies, fingerprint analysis, chemical markers, bio-responses, risk management and solution for quality process control. The quality and process control models for herbal medicinal products were proposed and the transitivity and traceability system from raw materials to the finished products was constructed to improve the herbal quality from the entire supply and production chain. The transitivity and traceability system has been established based on quality markers, especially on how to control the production process under Good Engineering Practices, as well as to implement the risk management for quality and process control in herbal medicine production. Copyright © 2018 Elsevier GmbH. All rights reserved.

  4. Suppression of polyglutamine toxicity by a Drosophila homolog of myeloid leukemia factor 1.

    PubMed

    Kazemi-Esfarjani, Parsa; Benzer, Seymour

    2002-10-01

    The toxicity of an abnormally long polyglutamine [poly(Q)] tract within specific proteins is the molecular lesion shared by Huntington's disease (HD) and several other hereditary neurodegenerative disorders. By a genetic screen in Drosophila, devised to uncover genes that suppress poly(Q) toxicity, we discovered a Drosophila homolog of human myeloid leukemia factor 1 (MLF1). Expression of the Drosophila homolog (dMLF) ameliorates the toxicity of poly(Q) expressed in the eye and central nervous system. In the retina, whether endogenously or ectopically expressed, dMLF co-localized with aggregates, suggesting that dMLF alone, or through an intermediary molecular partner, may suppress toxicity by sequestering poly(Q) and/or its aggregates.

  5. Apparatus for measuring internal friction Q factors in brittle materials. [applied to lunar samples

    NASA Technical Reports Server (NTRS)

    Tittmann, B. R.; Curnow, J. M.

    1976-01-01

    A flexural analog of the torsion pendulum for measuring the Young's modulus and the internal friction Q factor of brittle materials has been developed for Q greater than 10 to the 3rd measurements at a zero static stress and at 10 to the -7th strains of brittle materials in the Hz frequency range. The present design was motivated by the desire to measure Q in fragile lunar return samples at zero static stress to shed light on the anomalously low attenuation of seismic waves on the moon. The use of the apparatus is demonstrated with data on fused silica and on a terrestrial analog of lunar basalt.

  6. Oral Health Related Quality of Life among Tamil Speaking Adults Attending a Dental Institution in Chennai, Southern India

    PubMed Central

    Tadepalli, Anupama; Victor, Dhayanand John; Dharuman, Smriti

    2016-01-01

    Introduction Oral Health-Related Quality of Life (OHRQoL) indicates an individual’s perception of how their well-being and quality of life is influenced by oral health. It facilitates treatment planning, assessing patient centred treatment outcomes and satisfaction. Aim The study aimed to identify the factors influencing OHRQoL among Tamil speaking South Indian adult population. Materials and Methods Non-probability sampling was done and 199 subjects aged 20-70 years were recruited for this observational study. The subjects were requested to fill a survey form along with the validated Tamil General Oral Health Assessment Index (GOHAI-Tml) questionnaire in the waiting area following which clinical examination was done by a single experienced Periodontist. Results The mean score with standard deviation for physical dimension was 4.34±0.96, psychological dimension was 4.03±1.13 and pain was 4.05±1.09 on GOHAI. Greater impacts were seen for psychosocial dimensions like pleased with the appearance of teeth/denture Q7 (3.7±1.2), worried about the problems with teeth/denture Q9 (3.7±1) and pain or discomfort in teeth Q12 (3.8±1). Functions like swallowing Q3 (4.5±0.8) and speaking Q4 (4.6±0.7) were minimally affected. As age increased subjects perceived more negative impacts as indicated by lower ADD-GOHAI and higher SC-GOHAI scores (p<0.01). Subjects complaining of bad breath, bleeding gums and Temporomandibular Joint (TMJ) problems, reported poor OHRQoL (p<0.05). It was observed that as self-perceived oral and general health status deteriorated, OHRQoL also worsened (p<0.01). Subjects with missing teeth, cervical abrasion, restorations, gingival recession and mobility had more impacts on OHRQoL (p<0.05). Subjects diagnosed with periodontitis had lower OHRQoL as reported on the scale than gingivitis subjects (p<0.01). Conclusion In this study minimal impact was seen in all the three dimensions assessed with GOHAI. Factors like age, education, employment status, income, self-reported oral health, self-perceived general health, satisfaction with oral health, perceived need for treatment and denture wearing status influenced perceived OHRQoL. Bad breath, bleeding gums, TMJ problems, more number of missing teeth, decayed teeth, cervical abrasion, gingival recession and mobility were associated with poor OHRQoL. PMID:27891472

  7. Efficient expulsion of magnetic flux in superconducting radiofrequency cavities for high Q 0 applications

    DOE PAGES

    Posen, S.; Checchin, M.; Crawford, A. C.; ...

    2016-06-03

    Even when cooled through its transition temperature in the presence of an external magnetic field, a superconductor can expel nearly all external magnetic flux. This Letter presents an experimental study to identify the parameters that most strongly influence flux trapping in high purity niobium during cooldown. This is critical to the operation of superconducting radiofrequency cavities, in which trapped flux degrades the quality factor and therefore cryogenic efficiency. Flux expulsion was measured on a large survey of 1.3 GHz cavities prepared in various ways. It is shown that both spatial thermal gradient and high temperature treatment are critical to expellingmore » external magnetic fields, while surface treatment has minimal effect. For the first time, it is shown that a cavity can be converted from poor expulsion behavior to strong expulsion behavior after furnace treatment, resulting in a substantial improvement in quality factor. In conclusion, future plans are described to build on this result in order to optimize treatment for future cavities.« less

  8. Tunable High Q Superconducting Microwave Resonator for Hybrid System with ^87Rb atoms

    NASA Astrophysics Data System (ADS)

    Kim, Zaeill; Voigt, K. D.; Lee, Jongmin; Hoffman, J. E.; Grover, J. A.; Ravets, S.; Zaretskey, V.; Palmer, B. S.; Hafezi, M.; Taylor, J. M.; Anderson, J. R.; Dragt, A. J.; Lobb, C. J.; Orozco, L. A.; Rolston, S. L.; Wellstood, F. C.

    2012-02-01

    We have developed a frequency tuning system for a ``lumped-element'' thin-film superconducting Al microwave resonator [1] on sapphire intended for coupling to hyperfine ground states of cold trapped ^87Rb atoms, which are separated by about fRb=6.83 GHz. At T=12 mK and on resonance at 6.81 GHz, the loaded quality factor was 120,000. By moving a carefully machined Al pin towards the inductor of the resonator using a piezo stage, we were able to tune the resonance frequency over a range of 35 MHz and within a few kHz of fRb. While measuring the power dependent response of the resonator at each tuned frequency, we observed anomalous decreases in the quality factor at several frequencies. These drops were more pronounced at lower power. We discuss our results, which suggest these resonances are attributable to discrete two-level systems.[4pt] [1] Z. Kim et al., AIP ADVANCES 1, 042107 (2011).

  9. High Quality 3D Photonics using Nano Imprint Lithography of Fast Sol-gel Materials.

    PubMed

    Bar-On, Ofer; Brenner, Philipp; Siegle, Tobias; Gvishi, Raz; Kalt, Heinz; Lemmer, Uli; Scheuer, Jacob

    2018-05-18

    A method for the realization of low-loss integrated optical components is proposed and demonstrated. This approach is simple, fast, inexpensive, scalable for mass production, and compatible with both 2D and 3D geometries. The process is based on a novel dual-step soft nano imprint lithography process for producing devices with smooth surfaces, combined with fast sol-gel technology providing highly transparent materials. As a concrete example, this approach is demonstrated on a micro ring resonator made by direct laser writing (DLW) to achieve a quality factor improvement from one hundred thousand to more than 3 million. To the best of our knowledge this also sets a Q-factor record for UV-curable integrated micro-ring resonators. The process supports the integration of many types of materials such as light-emitting, electro-optic, piezo-electric, and can be readily applied to a wide variety of devices such as waveguides, lenses, diffractive elements and more.

  10. Review of the Frontier Workshop and Q-slope results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gianluigi Ciovati

    Over the last few years, significant progress has been made to produce field emission free niobium surfaces. Nowadays, the major limitation towards achieving the critical field in radio-frequency (rf) superconducting cavities made of bulk niobium of high purity is represented by the so-called ''high field Q-slope'' or ''Q-drop''. This phenomenon is characterized by a sharp decrease of the cavity quality factor, in absence of field emission, starting at a peak surface magnetic field of the order of 100 mT. It has been observed that these losses are usually reduced by a low-temperature ''in-situ'' baking, typically at 100-120 C for 24-48more » h. Several models have been proposed to explain the high field Q-slope and many experiments have been conducted in different laboratories to validate such models. A three-day workshop was held in Argonne in September 2004 to present and discuss experimental and theoretical results on the present limitations of superconducting rf cavities. In this paper, we will focus on the high field Q-slope by reviewing the results presented at the workshop along with other experimental data. In order to explain the Q-drop and the baking effect we will discuss an improved version of the oxygen diffusion model.« less

  11. Reliability and Validity of the Korean Version of the Cancer Stigma Scale.

    PubMed

    So, Hyang Sook; Chae, Myeong Jeong; Kim, Hye Young

    2017-02-01

    In this study the reliability and validity of the Korean version of the Cancer Stigma Scale (KCSS) was evaluated. The KCSS was formed through translation and modification of Cataldo Lung Cancer Stigma Scale. The KCSS, Psychological Symptom Inventory (PSI), and European Organization for Research and Treatment of Cancer Quality of Life Questionnaire - Core 30 (EORTC QLQ-C30) were administered to 247 men and women diagnosed with one of the five major cancers. Construct validity, item convergent and discriminant validity, concurrent validity, known-group validity, and internal consistency reliability of the KCSS were evaluated. Exploratory factor analysis supported the construct validity with a six-factor solution; that explained 65.7% of the total variance. The six-factor model was validated by confirmatory factor analysis (Q (χ²/df)= 2.28, GFI=.84, AGFI=.81, NFI=.80, TLI=.86, RMR=.03, and RMSEA=.07). Concurrent validity was demonstrated with the QLQ-C30 (global: r=-.44; functional: r=-.19; symptom: r=.42). The KCSS had known-group validity. Cronbach's alpha coefficient for the 24 items was .89. The results of this study suggest that the 24-item KCSS has relatively acceptable reliability and validity and can be used in clinical research to assess cancer stigma and its impacts on health-related quality of life in Korean cancer patients. © 2017 Korean Society of Nursing Science

  12. Partonic structure of neutral pseudoscalars via two photon transition form factors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Raya, Khepani; Ding, Minghui; Bashir, Adnan

    Here, the γγ* → η c,b transition form factors are computed using a continuum approach to the two valence-body bound-state problem in relativistic quantum field theory, and thereby unified with equivalent calculations of electromagnetic pion elastic and transition form factors. The resulting γγ* → η c form factor, G ηc(Q 2), is consistent with available data; significantly, at accessible momentum transfers, Q 2G ηc(Q 2) lies well below its conformal limit. These observations confirm that the leading-twist parton distribution amplitudes of heavy-heavy bound states are compressed relative to the conformal limit. A clear understanding of the distribution of valence quarksmore » within mesons thus emerges, a picture which connects Goldstone modes, built from the lightest quarks in nature, with systems containing the heaviest valence quarks that can now be studied experimentally, and highlights basic facts about manifestations of mass within the Standard Model.« less

  13. Partonic structure of neutral pseudoscalars via two photon transition form factors

    DOE PAGES

    Raya, Khepani; Ding, Minghui; Bashir, Adnan; ...

    2017-04-10

    Here, the γγ* → η c,b transition form factors are computed using a continuum approach to the two valence-body bound-state problem in relativistic quantum field theory, and thereby unified with equivalent calculations of electromagnetic pion elastic and transition form factors. The resulting γγ* → η c form factor, G ηc(Q 2), is consistent with available data; significantly, at accessible momentum transfers, Q 2G ηc(Q 2) lies well below its conformal limit. These observations confirm that the leading-twist parton distribution amplitudes of heavy-heavy bound states are compressed relative to the conformal limit. A clear understanding of the distribution of valence quarksmore » within mesons thus emerges, a picture which connects Goldstone modes, built from the lightest quarks in nature, with systems containing the heaviest valence quarks that can now be studied experimentally, and highlights basic facts about manifestations of mass within the Standard Model.« less

  14. A Q-methodological study of smoking identities.

    PubMed

    Farrimond, Hannah; Joffe, Helene; Stenner, Paul

    2010-10-01

    In contrast to the psychological literature on adolescent smoking, little research has investigated the social identities of adult smokers. This study aimed to identify shared 'smoking identities' amongst a sample of 64 British smokers from different socio-economic groups using Q-methodology. Participants were asked to sort 70 items concerning smoking and smokers according to their agreement/disagreement with them. The 64 Q-sorts were then subjected to a by-person factor analysis yielding six factors, with the first four interpretable factors being presented here. Each factor is understood to represent a distinct 'identity position'. The first two, the 'addicted' smoker, and the 'in control' smoker, oriented around a biomedical model of smoking as an addictive health risk. The final two, the 'no big deal' smoker and the 'proud' smoker reflected alternative understandings and values. The identity positions also differed in the extent to which smoking was considered a core part of self-identity. Unpacking the 'smoking identities' of current smokers offers the opportunity to devise targeted health promotion.

  15. Dietary fat intake and quality of life: the SUN project.

    PubMed

    Ruano, Cristina; Henriquez, Patricia; Bes-Rastrollo, Maira; Ruiz-Canela, Miguel; del Burgo, Cristina López; Sánchez-Villegas, Almudena

    2011-11-02

    Few studies have related nutritional factors with quality of life in healthy populations. The purpose of the study was to assess whether dietary fat intake is associated to mental and physical quality of life. This analysis included 8,430 participants from the SUN (Seguimiento Universidad de Navarra) Project. The intake of saturated fatty acids (SFA), polyunsaturated fatty acids (PUFA), trans unsaturated fatty acids (TFA), and monounsaturated fatty acids (MUFA) was assessed through a 136-item food frequency questionnaire at baseline. Quality of life was measured with the SF-36 Health Survey after 4 years of follow-up. Generalized Linear Models were fitted to assess the regression coefficients (b) and their 95% confidence intervals (95% CI) for the 8 domains of the SF-36 according to successive quintiles of each kind of fatty acids intake. The multivariate-adjusted models revealed a significant inverse association for SFA intake (in quintiles) and two of the physical domains (physical functioning and general health). E.g. for general health domain: (highest quintile of intake (Q5) vs. lowest quintile (Q1), b = -1.6; 95% CI = -3.1, -0.1. General health also showed a dose-response relationship (p for trend < 0.05). For TFA intake (in quintiles), a significant inverse association was found for most of the mental domains (vitality, social functioning and role emotional). E.g. for vitality domain (Q5) vs. (Q1), b = -2.0, 95% CI = -3.4 to -0.6. We also found an inverse association between TFA intake and the bodily pain domain: (Q5 vs. Q1), b = -2.6; 95% CI = -4.4 to -0.8, with a statistically significant dose-response relationship (p for trend < 0.05). Except for TFA intake and the mental domains, the rest of the associations were attenuated when we repeated the analysis adjusting for adherence to the Mediterranean diet. A detrimental relationship between TFA intake at baseline and most of the SF-36 mental domains measured 4 years later were found, whereas weak inverse associations were found for SFA intake and some physical domains.

  16. Photonic crystal nanofiber air-mode cavity with high Q-factor and high sensitivity for refractive index sensing

    NASA Astrophysics Data System (ADS)

    Ma, Xiaoxue; Chen, Xin; Nie, Hongrui; Yang, Daquan

    2018-01-01

    Recently, due to its superior characteristics and simple manufacture, such as small size, low loss, high sensitivity and convenience to couple, the optical fiber sensor has become one of the most promising sensors. In order to achieve the most effective realization of light propagation by changing the structure of sensors, FOM(S •Q/λres) ,which is determined by two significant variables Q-factor and sensitivity, as a trade-off parameter should be optimized to a high value. In typical sensors, a high Q can be achieved by confining the optical field in the high refractive index dielectric region to make an interaction between analytes and evanescent field of the resonant mode. However, the ignored sensitivity is relatively low with a high Q achieved, which means that the resonant wavelength shift changes non-obviously when the refractive index increases. Meanwhile, the sensitivity also leads to a less desirable FOM. Therefore, a gradient structure, which can enhance the performance of sensors by achieving high Q and high sensitivity, has been developed by Kim et al. later. Here, by introducing parabolic-tapered structure, the light field localized overlaps strongly and sufficiently with analytes. And based on a one-dimensional photonic-crystal nanofiber air-mode cavity, a creative optical fiber sensor is proposed by combining good stability and transmission characteristics of fiber and strengths of tapered structure, realizing excellent FOM {4.7 x 105 with high Q-factors (Q{106) and high sensitivities (<700 nm/RIU).

  17. Pair correlation functions and the wavevector-dependent surface tension in a simple density functional treatment of the liquid-vapour interface.

    PubMed

    Parry, A O; Rascón, C; Willis, G; Evans, R

    2014-09-03

    We study the density-density correlation function G(r, r') in the interfacial region of a fluid (or Ising-like magnet) with short-ranged interactions using square gradient density functional theory. Adopting a simple double parabola approximation for the bulk free-energy density, we first show that the parallel Fourier transform G(z, z'; q) and local structure factor S(z; q) separate into bulk and excess contributions. We attempt to account for both contributions by deriving an interfacial Hamiltonian, characterised by a wavevector dependent surface tension σ(q), and then reconstructing density correlations from correlations in the interface position. We show that the standard crossing criterion identification of the interface, as a surface of fixed density (or magnetization), does not explain the separation of G(z, z'; q) and the form of the excess contribution. We propose an alternative definition of the interface position based on the properties of correlations between points that 'float' with the surface and show that this describes the full q and z dependence of the excess contributions to both G and S. However, neither the 'crossing-criterion' nor the new 'floating interface' definition of σ(q) are quantities directly measurable from the total structure factor S(tot)(q) which contains additional q dependence arising from the non-local relation between fluctuations in the interfacial position and local density. Since it is the total structure factor that is measured experimentally or in simulations, our results have repercussions for earlier attempts to extract and interpret σ(q).

  18. Monte Carlo and experimental determination of correction factors for gamma knife perfexion small field dosimetry measurements

    NASA Astrophysics Data System (ADS)

    Zoros, E.; Moutsatsos, A.; Pappas, E. P.; Georgiou, E.; Kollias, G.; Karaiskos, P.; Pantelis, E.

    2017-09-01

    Detector-, field size- and machine-specific correction factors are required for precise dosimetry measurements in small and non-standard photon fields. In this work, Monte Carlo (MC) simulation techniques were used to calculate the k{{Qmsr},{{Q}0}}{{fmsr},{{f}ref}} and k{{Qclin},{{Q}msr}}{{fclin},{{f}msr}} correction factors for a series of ionization chambers, a synthetic microDiamond and diode dosimeters, used for reference and/or output factor (OF) measurements in the Gamma Knife Perfexion photon fields. Calculations were performed for the solid water (SW) and ABS plastic phantoms, as well as for a water phantom of the same geometry. MC calculations for the k{{Qclin},{{Q}msr}}{{fclin},{{f}msr}} correction factors in SW were compared against corresponding experimental results for a subset of ionization chambers and diode detectors. Reference experimental OF data were obtained through the weighted average of corresponding measurements using TLDs, EBT-2 films and alanine pellets. k{{Qmsr},{{Q}0}}{{fmsr},{{f}ref}} values close to unity (within 1%) were calculated for most of ionization chambers in water. Greater corrections of up to 6.0% were observed for chambers with relatively large air-cavity dimensions and steel central electrode. A phantom correction of 1.006 and 1.024 (breaking down to 1.014 from the ABS sphere and 1.010 from the accompanying ABS phantom adapter) were calculated for the SW and ABS phantoms, respectively, adding up to k{{Qmsr},{{Q}0}}{{fmsr},{{f}ref}} corrections in water. Both measurements and MC calculations for the diode and microDiamond detectors resulted in lower than unit k{{Qclin},{{Q}msr}}{{fclin},{{f}msr}} correction factors, due to their denser sensitive volume and encapsulation materials. In comparison, higher than unit k{{Qclin},{{Q}msr}}{{fclin},{{f}msr}} results for the ionization chambers suggested field size depended dose underestimations (being significant for the 4 mm field), with magnitude depending on the combination of contradicting phenomena associated with volume averaging and electron fluence perturbations. Finally, the presence of 0.5 mm air-gap between the diodes’ frontal surface and their phantom-inserts may considerably influence OF measurements, reaching 4.6% for the Razor diode.

  19. Expression of Shiga toxin 2 (Stx2) in highly virulent Stx-producing Escherichia coli (STEC) carrying different anti-terminator (q) genes.

    PubMed

    Olavesen, Kristoffer K; Lindstedt, Bjørn-Arne; Løbersli, Inger; Brandal, Lin T

    2016-08-01

    Shiga toxins (Stx) are key virulence factors of Shiga toxin-producing Escherichia coli (STEC) during development of haemolytic uremic syndrome (HUS). It has been suggested that not only specific stx2 subtypes, but also the amount of Stx2 expressed might be essential for STEC pathogenicity. We aimed to investigate if various anti-terminator (q) genes might influence the expression level of Stx2 in highly virulent STEC. A multiplex PCR detecting q933, q21, and qO111 was run on 20 stx2a-positive STEC strains, of which 18 were HUS associated serotypes (HAS) and two non-HAS. Relative expression of Stx2 mRNA was assessed for all strains, both in non-induced and induced (mitomycin C) state. The HAS STEC carried either q933 (n = 8), qO111 (n = 8), or both (n = 2). In basal state, no STEC strains showed higher expression of Stx2 mRNA than the calibrator EDL933 (non-sorbitol fermenting (NSF) O157:H7carrying q933). Variations among strains were not associated with different q genes present, but rather related to specific serogroups. In induced state, O104:H4 strains (q933) showed higher Stx2 mRNA level than EDL933, whereas sorbitol fermenting (SF) O157:H- (qO111) and O121:H? (q933) STEC showed levels comparable with EDL933. An association between the presence of q933 and higher Stx2 level was seen within some HAS, but not all. Interestingly, the O103:H25 STEC strains, responsible for a HUS outbreak in Norway, carried both q933 and qO111. However, the Stx2 mRNA level in these strains was significantly lower than EDL933 in both states, indicating that other factors than the level of Stx2 might explain the aggressiveness of these bacteria. The two non-HAS STEC did not carry any of the examined q genes. In induced state, these bacteria showed the lowest Stx2 mRNA level compared to EDL933. One of the non-HAS STEC was not induced by mitomycin C, suggesting that stx2a might be located on a defect bacteriophage. No association between specific q genes and Stx2 mRNA expression level was revealed in stx2a-positive HAS STEC. Our results suggest that other factor(s) than specific q genes might influence the level of Stx2 produced in highly virulent STEC. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. [The salivary factors related to caries and periodontal disease in children and adolescents with diabetes mellitus].

    PubMed

    Wang, Meng-xing; Wang, Xin; Zhang, Zhi; Qin, Man

    2013-09-01

    To detect the salivary factors related to caries and periodontal disease and to analyze the risk of caries and periodontal disease in children and adolescents with diabetes mellitus. The study comprised 30 children with diabetic mellitus, aged 7-15 years old, and 60 healthy age-and gender-matched children. Caries and periodontal indexes were recorded and saliva related factors were analyzed. Caries indexes of diabetes children [permanent teeth: decay missing filling tooth (DMFT) M (Q1,Q3) = 0(0, 4), deciduous teeth: decay missing filling tooth (dmft) M (Q1,Q3) = 0(0, 1)] were not significantly different with those of healthy children [DMFT M (Q1,Q3) = 1(0, 3), dmft M (Q1,Q3) = 0(0, 4)], but plaque index (PLI) (1.25 ± 0.33) and bleeding index (BI) (0.74 ± 0.45) of diabetes children were significantly higher than those of healthy children (PLI was 0.93 ± 0.31,BI was 0.34 ± 0.22) (P < 0.001). Salivary pH of diabetes children (7.68 ± 0.36) was significantly higher than that of healthy children (7.30 ± 0.32) (P < 0.05), and salivary acid buffering capacity had no significant difference between the two groups (P > 0.05). Salivary glucose, immunoglobulin sIgA and sIgG were not significantly different between the two groups (P > 0.05).Salivary lysozyme of diabetes children was significantly higher than that of healthy children (P < 0.05). Total protein was significantly lower in diabetes children than in healthy children (P < 0.05). Salivary lactate dehydrogenase had no significant difference between the two groups (P > 0.05). Diabetes mellitus can lead to the changes of some salivary factors related to gingivitis in diabetes children. Children and adolescents with diabetes mellitus may have a higher risk of periodontal disease.

  1. High permittivity and low loss ceramics in the BaO-SrO-Nb{sub 2}O{sub 5} system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sreemoolanadhan, H.; Sebastian, M.T.; Mohanan, P.

    1995-06-01

    A new group of compounds with composition (Ba{sub 5{minus}X}Sr{sub x})Nb{sub 4}O{sub 15}, having high permittivity and low loss have been prepared and characterized in the microwave frequency region. X-ray diffraction studies showed that monophase compound existed for all values of x from 0 to 5. Microwave dielectric properties such as {var_epsilon}{sub r} and {tau}{sub f} showed smooth variation with x, while the unloaded quality factor (Q{sub u}) showed remarkable improvement with x. A range of ceramic dielectric resonators (DR) with 40 < {var_epsilon}{sub r} < 50, {minus}10 < {tau}{sub f} < +10 and Q {times} f > 10,000 can bemore » obtained in this system.« less

  2. Miniature lowpass filters in low loss 9k7 LTCC

    DOE PAGES

    Dai, Steve; Hsieh, Lung -Hwa

    2015-07-01

    DuPont 9k7 low temperature cofired ceramic (LTCC) is a low loss, or high quality factor Q, tape system targeting at radio frequency (RF) applications. This paper reports the effect of a critical process parameter, heating rate, on the densification and dielectric properties of the 9k7 LTCC. The role of competing densification and crystallization during the sintering of 9k7 is discussed. The high Q of DuPont 9K7 can be used to improve RF system performance, for example a better receiver noise figure, by designing embedded passive RF components such as inductors, capacitors and filters. As a result, miniaturized multilayer low passmore » filters (LPF) with a wide stopband were fabricated to showcase the technology.« less

  3. Miniature lowpass filters in low loss 9k7 LTCC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dai, Steve; Hsieh, Lung -Hwa

    DuPont 9k7 low temperature cofired ceramic (LTCC) is a low loss, or high quality factor Q, tape system targeting at radio frequency (RF) applications. This paper reports the effect of a critical process parameter, heating rate, on the densification and dielectric properties of the 9k7 LTCC. The role of competing densification and crystallization during the sintering of 9k7 is discussed. The high Q of DuPont 9K7 can be used to improve RF system performance, for example a better receiver noise figure, by designing embedded passive RF components such as inductors, capacitors and filters. As a result, miniaturized multilayer low passmore » filters (LPF) with a wide stopband were fabricated to showcase the technology.« less

  4. Miniature low-pass filter in low-loss 9k7 LTCC

    DOE PAGES

    Dai, Steve Xunhu; Hsieh, Lung -Hwa

    2015-09-30

    DuPont 9k7 low-temperature cofired ceramic (LTCC) is a low-loss, or high-quality-factor Q, tape system targeting at radio frequency (RF) applications. This paper reports on the effect of a critical process parameter, the heating rate, on the densification and dielectric properties of the 9k7 LTCC. The role of competing densification and crystallization during the sintering of 9k7 is discussed. The high Q of DuPont 9K7 can be used to improve RF system performance, for example a better receiver noise figure, by designing embedded passive RF components such as inductors, capacitors and filters. Furthermore, miniaturized multilayer low-pass filters (LPF) with a widemore » stopband were fabricated to showcase the technology.« less

  5. Attenuation Characteristics of the Armutlu Peninsula (NW Turkey) Using Coda Q

    NASA Astrophysics Data System (ADS)

    Yavuz, Evrim; Çaka, Deniz; Tunç, Berna; Woith, Heiko; Gottfried Lühr, Birger; Barış, Şerif

    2016-04-01

    Attenuation characteristic of seismic waves was determined using coda Q in the frame of MARsite (MARsite has received funding from the European Union's Seventh Programme for research, technological development and demonstration under grant agreement No 308417). Data from 82 earthquakes recorded in 2013-2014 in the Armutlu Peninsula and its vicinity by 9 ARNET seismic stations were used for processing. The earthquake magnitudes (Ml) and depths vary from 1.5 to 3.7 and 1.2-16.9 km, respectively. Epicentral distances closer than 90 km were selected to ensure better signal-to-noise ratios. Lapse times between 20 seconds and 40 seconds at intervals of 5 seconds were used for the calculation of the coda wave quality factor. The coda windows were filtered at central frequencies of 1.5, 3, 6, 9 and 12 Hz bandpass filter. To obtain reliable results, only data with signal-to-noise ratios greater than 5 and correlation coefficents higher than 0.7 were used. The SEISAN software and one of its subroutines (CODAQ) were used for data processing and analyses. In the whole study area, Qc=(51±4)f^(0.91±0.04) for 20 seconds, Qc=(77±7)f^(0.80±0.04) for 30 seconds and Qc=(112±13)f^(0.72±0.06) for 40 seconds lapse times are obtained for coda wave quality factor. The observed quality factor is dependent on frequency and lapse time. The results indicate that the upper lithosphere is more heterogeneous and seismically more active than the lower lithosphere as expected in the region which is tectonically complex refering to the effects of the North Anatolian Fault Zone. By considering earthquake clusters and recorded stations, the scattering area was drawn. The intersection of the scattered areas for 20 seconds lapse time is covering all stations. Quality factor in 1 Hz and frequency dependent values were calculated separately and for the intersection of all scattered areas. Calculated Qo and n values of the intersection area are 50 and 0.89, respectively. Hence, the Qo and n values which are calculated using all stations and both values of the intersection area are very close to each other. Additionally, in the detailed review of TRML station which located in Yalova Province Termal District; Qc=(46±3)f^(0.97±0.04) for 20 seconds, Qc=(61±6)f^(1.03±0.06), for 30 seconds and Qc=(74±6)f^(1.06±0.05) for 40 seconds lapse times are obtained for coda wave quality factor. With these results, both the lower Qo values increasing with lapse times demonstrate high tectonic activity. Furthermore, the increasing n value with lapse times is conformable with the geothermal sources, next to the TRML station.

  6. Inhibition of liver fibrosis by solubilized coenzyme Q10: Role of Nrf2 activation in inhibiting transforming growth factor-beta1 expression

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choi, Hoo-Kyun; Pokharel, Yuba Raj; Lim, Sung Chul

    2009-11-01

    Coenzyme Q10 (CoQ10), an endogenous antioxidant, is important in oxidative phosphorylation in mitochondria. It has anti-diabetic and anti-cardiovascular disease effects, but its ability to protect against liver fibrosis has not been studied. Here, we assessed the ability of solubilized CoQ10 to improve dimethylnitrosamine (DMN)-induced liver fibrogenesis in mice. DMN treatments for 3 weeks produced a marked liver fibrosis as assessed by histopathological examination and tissue 4-hydroxyproline content. Solubilized CoQ10 (10 and 30 mg/kg) significantly inhibited both the increases in fibrosis score and 4-hydroxyproline content induced by DMN. Reverse transcription-polymerase chain reaction and Western blot analyses revealed that solubilized CoQ10 inhibitedmore » increases in the transforming growth factor-beta1 (TGF-beta1) mRNA and alpha-smooth muscle actin (alpha-SMA) protein by DMN. Interestingly, hepatic glutamate-cysteine ligase (GCL) and glutathione S-transferase A2 (GSTA2) were up-regulated in mice treated with CoQ10. Solubilized CoQ10 also up-regulated antioxidant enzymes such as catalytic subunits of GCL and GSTA2 via activating NF-E2 related factor2 (Nrf2)/antioxidant response element (ARE) in H4IIE hepatoma cells. Moreover, CoQ10's inhibition of alpha-SMA and TGF-beta1 expressions disappeared in Nrf2-null MEF cells. In contrast, Nrf2 overexpression significantly decreased the basal expression levels of alpha-SMA and TGF-beta1 in Nrf2-null MEF cells. These results demonstrated that solubilized CoQ10 inhibited DMN-induced liver fibrosis through suppression of TGF-beta1 expression via Nrf2/ARE activation.« less

  7. Quality Control of RNA Preservation and Extraction from Paraffin-Embedded Tissue: Implications for RT-PCR and Microarray Analysis

    PubMed Central

    Pichler, Martin; Zatloukal, Kurt

    2013-01-01

    Analysis of RNA isolated from fixed and paraffin-embedded tissues is widely used in biomedical research and molecular pathological diagnostics. We have performed a comprehensive and systematic investigation of the impact of factors in the pre-analytical workflow, such as different fixatives, fixation time, RNA extraction method and storage of tissues in paraffin blocks, on several downstream reactions including complementary DNA (cDNA) synthesis, quantitative reverse transcription polymerase chain reaction (qRT-PCR) and microarray hybridization. We compared the effects of routine formalin fixation with the non-crosslinking, alcohol-based Tissue Tek Xpress Molecular Fixative (TTXMF, Sakura Finetek), and cryopreservation as gold standard for molecular analyses. Formalin fixation introduced major changes into microarray gene expression data and led to marked gene-to-gene variations in delta-ct values of qRT-PCR. We found that qRT-PCR efficiency and gene-to-gene variations were mainly attributed to differences in the efficiency of cDNA synthesis as the most sensitive step. These differences could not be reliably detected by quality assessment of total RNA isolated from formalin-fixed tissues by electrophoresis or spectrophotometry. Although RNA from TTXMF fixed samples was as fragmented as RNA from formalin fixed samples, much higher cDNA yield and lower ct-values were obtained in qRT-PCR underlining the negative impact of crosslinking by formalin. In order to better estimate the impact of pre-analytical procedures such as fixation on the reliability of downstream analysis, we applied a qRT-PCR-based assay using amplicons of different length and an assay measuring the efficiency of cDNA generation. Together these two assays allowed better quality assessment of RNA extracted from fixed and paraffin-embedded tissues and should be used to supplement quality scores derived from automated electrophoresis. A better standardization of the pre-analytical workflow, application of additional quality controls and detailed sample information would markedly improve the comparability and reliability of molecular studies based on formalin-fixed and paraffin-embedded tissue samples. PMID:23936242

  8. Quarantine versus pathogen-reduced plasma-coagulation factor content and rotational thromboelastometry coagulation.

    PubMed

    Theusinger, Oliver M; Goslings, David; Studt, Jan-Dirk; Brand-Staufer, Brigitte; Seifert, Burkhardt; Spahn, Donat R; Frey, Beat M

    2017-03-01

    Different types of fresh-frozen plasma (FFP) exist, and the concentrations of plasma proteins vary between individuals and blood groups. Furthermore, processing may also influence the content. Quarantine-stored plasma (qFFP) and plasma that was pathogen-reduced using blood-safety (Intercept) technology (piFFP) were analyzed regarding procoagulant and anticoagulant hemostasis proteins, including endogenous thrombin (thrombin-generation) potential (ETP). Thirty-five samples of each type of FFP were analyzed using only male Blood Group O donors. FFP units were stored frozen for comparable periods of time before plasma protein content was assessed. Once the units were thawed, all tests were completed within 4 hours. The results are presented as means ± standard deviations or as median (minimum; maximum) and were compared using independent-sample t tests (significance, p < 0.01). Significantly higher concentrations of adintegrin-like and metalloprotease with thrombospondin type-13 motifs (ADAMTS13), fibrinogen, Factor (F)V, FVIII, FXIII, protein S, protein S activity, antithrombin, microvesicle (<900 nm), and α2 antiplasmin were observed in qFFP. The variability of factors was significantly lower in piFFP. Tissue factor (TF) at 1 picomolar (pM) exhibited significantly longer lag time, a lower peak, lower ETP, and a lower velocity index in qFFP compared with piFFP. In TF at 5 pM, significant differences in lag time (longer in qFFP), velocity index (lower in qFFP), and peak (lower in qFFP) were observed. Rotational thromboelastometry revealed a significantly longer (p = 0.002) clot-formation time with intrinsic thromboelastometry for piFFP and a significantly shorter clotting time (p = 0.004) with thromboelastometry fibrinogen testing for piFFP. Pathogen reduction reduces procoagulant and anticoagulant coagulation factors as well as variability. A thrombin-generation assay showed no reduced ETP and no supraphysiological thrombin generation. None of the FFP preparations is likely to be effective for treating fibrinogen deficiency. © 2016 AABB.

  9. R353Q polymorphism in the factor VII gene and cardiovascular risk in Heterozygous Familial Hypercholesterolemia: a case-control study.

    PubMed

    Criado-García, Juan; Fuentes, Francisco; Cruz-Teno, Cristina; García-Rios, Antonio; Jiménez-Morales, Anabel; Delgado-Lista, Javier; Mata, Pedro; Alonso, Rodrigo; López-Miranda, José; Pérez-Jiménez, Francisco

    2011-04-09

    Heterozygous Familial Hypercholesterolemia (FH) is a genetic disorder characterized by a high risk of cardiovascular disease. Certain polymorphisms of the factor VII gene have been associated with the development of coronary artery disease and there is a known association between factor VII levels and polymorphic variants in this gene. To date, no study has evaluated the association between factor VII and coronary artery disease in patients with FH. This case-control study comprised 720 patients (546 with FH and 174 controls). We determined the prevalence and allele frequencies of the R353Q polymorphism of factor VII, the plasma levels of factor VII antigen (FVII Ag) and whether they could be predictive factors for cardiovascular risk. 75% (410) of the patients with FH were RR, 23% (127) RQ and 1.6% (9) QQ; in the control group 75.3% (131) were RR, 21.3% (37) RQ and 3.4% (6) QQ (p = 0.32). No statistically significant associations were observed in the distribution of genotypes and allele frequencies between case (FH) and control groups. Nor did we find differences when we evaluated the relationship between the R353Q polymorphism and cardiovascular risk (including coronary disease, ischemic stroke and peripheral arterial disease), either in the univariate analysis or after adjustment for sex, age, arterial hypertension, body mass index, xanthomas, diabetes, smoking, HDLc and LDLc and lipid-lowering treatment. The FVII Ag concentrations behaved in a similar fashion, with no differences for the interaction between controls and those with FH (RR vs. RQ/QQ; p = 0.96). In the subgroup of patients with FH no association was found among cardiovascular disease, genotype and FVII Ag levels (RR vs. RQ/QQ; p = 0.97). Our study did not find a direct relationship between cardiovascular risk in patients with Heterozygous Familial Hypercholesterolemia, the R353Q polymorphism of factor VII and FVII Ag levels.

  10. R353Q polymorphism in the factor VII gene and cardiovascular risk in Heterozygous Familial Hypercholesterolemia: a case-control study

    PubMed Central

    2011-01-01

    Background Heterozygous Familial Hypercholesterolemia (FH) is a genetic disorder characterized by a high risk of cardiovascular disease. Certain polymorphisms of the factor VII gene have been associated with the development of coronary artery disease and there is a known association between factor VII levels and polymorphic variants in this gene. To date, no study has evaluated the association between factor VII and coronary artery disease in patients with FH. Results This case-control study comprised 720 patients (546 with FH and 174 controls). We determined the prevalence and allele frequencies of the R353Q polymorphism of factor VII, the plasma levels of factor VII antigen (FVII Ag) and whether they could be predictive factors for cardiovascular risk. 75% (410) of the patients with FH were RR, 23% (127) RQ and 1.6% (9) QQ; in the control group 75.3% (131) were RR, 21.3% (37) RQ and 3.4% (6) QQ (p = 0.32). No statistically significant associations were observed in the distribution of genotypes and allele frequencies between case (FH) and control groups. Nor did we find differences when we evaluated the relationship between the R353Q polymorphism and cardiovascular risk (including coronary disease, ischemic stroke and peripheral arterial disease), either in the univariate analysis or after adjustment for sex, age, arterial hypertension, body mass index, xanthomas, diabetes, smoking, HDLc and LDLc and lipid-lowering treatment. The FVII Ag concentrations behaved in a similar fashion, with no differences for the interaction between controls and those with FH (RR vs. RQ/QQ; p = 0.96). In the subgroup of patients with FH no association was found among cardiovascular disease, genotype and FVII Ag levels (RR vs. RQ/QQ; p = 0.97). Conclusions Our study did not find a direct relationship between cardiovascular risk in patients with Heterozygous Familial Hypercholesterolemia, the R353Q polymorphism of factor VII and FVII Ag levels. PMID:21477332

  11. Calculation Method of Lateral Strengths and Ductility Factors of Constructions with Shear Walls of Different Ductility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamaguchi, Nobuyoshi; Nakao, Masato; Murakami, Masahide

    2008-07-08

    For seismic design, ductility-related force modification factors are named R factor in Uniform Building Code of U.S, q factor in Euro Code 8 and Ds (inverse of R) factor in Japanese Building Code. These ductility-related force modification factors for each type of shear elements are appeared in those codes. Some constructions use various types of shear walls that have different ductility, especially for their retrofit or re-strengthening. In these cases, engineers puzzle the decision of force modification factors of the constructions. Solving this problem, new method to calculate lateral strengths of stories for simple shear wall systems is proposed andmore » named 'Stiffness--Potential Energy Addition Method' in this paper. This method uses two design lateral strengths for each type of shear walls in damage limit state and safety limit state. Two lateral strengths of stories in both limit states are calculated from these two design lateral strengths for each type of shear walls in both limit states. Calculated strengths have the same quality as values obtained by strength addition method using many steps of load-deformation data of shear walls. The new method to calculate ductility factors is also proposed in this paper. This method is based on the new method to calculate lateral strengths of stories. This method can solve the problem to obtain ductility factors of stories with shear walls of different ductility.« less

  12. Measuring patients' satisfaction with their anti-TNF treatment in severe Crohn's disease: scoring and psychometric validation of the Satisfaction for PAtients in Crohn's diseasE Questionnaire (SPACE-Q(©)).

    PubMed

    Gilet, Hélène; Arnould, Benoit; Fofana, Fatoumata; Clerson, Pierre; Colombel, Jean-Frédéric; D'Hondt, Olivier; Faure, Patrick; Hagège, Hervé; Nachury, Maria; Nahon, Stéphane; Tucat, Gilbert; Vandromme, Luc; Cazala-Telinge, Ines; Thibout, Emmanuel

    2014-01-01

    Severe Crohn's disease management includes anti-tumor necrosis factor (anti-TNF) drugs that differ from early-stage treatments regarding efficacy, safety, and convenience. This study aimed to finalize and psychometrically validate the Satisfaction for PAtients in Crohn's diseasE Questionnaire (SPACE-Q(©)), developed to measure satisfaction with anti-TNF treatment in patients with severe Crohn's disease. A total of 279 patients with severe Crohn's disease receiving anti-TNF therapy completed the SPACE-Q 62-item pilot version at inclusion and 12 and 13 weeks after first anti-TNF injection. The final SPACE-Q scoring was defined using multitrait and regression analyses and clinical relevance considerations. Psychometric validation included clinical validity against Harvey-Bradshaw score, concurrent validity against Treatment Satisfaction Questionnaire for Medication (TSQM), internal consistency reliability, test-retest reliability, and responsiveness against the patient global impression of change (PGIC). Quality of completion was good (55%-67% of patients completed all items). Four items were removed from the questionnaire. Eleven scores were defined within the final 58-item SPACE-Q: disease control; symptoms, anal symptoms, and quality of life transition scales; tolerability; convenience; expectation confirmation toward efficacy, side effects, and convenience; satisfaction with treatment; and motivation. Scores met standards for concurrent validity (correlation between SPACE-Q satisfaction with treatment and TSQM satisfaction scores =0.59), internal consistency reliability (Cronbach's α=0.67-0.93), test-retest reliability (intraclass correlations =0.62-0.91), and responsiveness (improvement in treatment experience assessed by the SPACE-Q for patients reporting improvement on the PGIC). Significantly different mean scores were observed between groups of patients with different Harvey-Bradshaw disease severity scores. The SPACE-Q is a valid, reliable, and responsive instrument to measure satisfaction with anti-TNF treatment in patients with severe Crohn's disease and for use in future studies.

  13. Study of the AC machines winding having fractional q

    NASA Astrophysics Data System (ADS)

    Bespalov, V. Y.; Sidorov, A. O.

    2018-02-01

    The winding schemes with a fractional numbers of slots per pole and phase q have been known and used for a long time. However, in the literature on the low-noise machines design there are not recommended to use. Nevertheless, fractional q windings have been realized in many applications of special AC electrical machines, allowing to improve their performance, including vibroacoustic one. This paper deals with harmonic analysis of windings having integer and fractional q in permanent magnet synchronous motors, a comparison of their characteristics is performed, frequencies of subharmonics are revealed. Optimal winding pitch design is found giving reduce the amplitudes of subharmonics. Distribution factors for subharmonics, fractional and high-order harmonics are calculated, results analysis is represented, allowing for giving recommendations how to calculate distribution factors for different harmonics when q is fractional.

  14. Performance analysis of hybrid vibrational energy harvesters with experimental verification

    NASA Astrophysics Data System (ADS)

    Sriramdas, Rammohan; Pratap, Rudra

    2018-07-01

    In the present work, performance indices for a hybrid energy harvester (HEH) that is composed of piezoelectric and electrodynamic or electromagnetic mechanisms of energy conversion are analyzed. Performance of a HEH is defined in terms of Q-normalized power factor and efficiency of conversion. They are observed to acutely depend on coupling strength or figures of merit in both piezoelectric and electrodynamic domains. The influence of figures of merit on the Q-normalized power factor, and the limits of conversion efficiency are explored. Based on the studies, a suitable range for figures of merit that would maximize both Q-normalized power factor and conversion efficiency in hybrid harvesters is proposed. The proposed idea is verified experimentally for the appropriate values of figures of merit and efficiencies by fabricating and testing four experimental models of the HEHs.

  15. Optical micro-bubble resonators as promising biosensors

    NASA Astrophysics Data System (ADS)

    Giannetti, A.; Barucci, A.; Berneschi, S.; Cosci, A.; Cosi, F.; Farnesi, D.; Nunzi Conti, G.; Pelli, S.; Soria, S.; Tombelli, S.; Trono, C.; Righini, G. C.; Baldini, F.

    2015-05-01

    Recently, optical micro-bubble resonators (OMBRs) have gained an increasing interest in many fields of photonics thanks to their particular properties. These hollow microstructures can be suitable for the realization of label - free optical biosensors by combining the whispering gallery mode (WGM) resonator properties with the intrinsic capability of integrated microfluidics. In fact, the WGMs are morphology-dependent modes: any change on the OMBR inner surface (due to chemical and/or biochemical binding) causes a shift of the resonance position and reduces the Q factor value of the cavity. By measuring this shift, it is possible to obtain information on the concentration of the analyte to be detected. A crucial step for the development of an OMBR-based biosensor is constituted by the functionalization of its inner surface. In this work we report on the development of a physical and chemical process able to guarantee a good homogeneity of the deposed bio-layer and, contemporary, to preserve a high quality factor Q of the cavity. The OMBR capability of working as bioassay was proved by different optical techniques, such as the real time measurement of the resonance broadening after each functionalization step and fluorescence microscopy.

  16. Phase gradient metasurface with broadband anomalous reflection based on cross-shaped units

    NASA Astrophysics Data System (ADS)

    Chen, Zhaobin; Deng, Hui; Xiong, Qingxu; Liu, Chen

    2018-03-01

    It has been pointed out by many documents that a phase gradient metasurface with wideband characteristics can be designed by the unit with a low-quality factor ( Q value). In this paper, a cross-shaped unit with a low-quality factor Q is proposed. By changing the variable parameters of the unit, it is found that the reflection phase of the unit can achieve a stable distribution of phase gradient in the frequency range of 8.0-20.0 GHz. we analyze variation of the electromagnetic field distribution on the unit with frequency and find that the size along electrical field polarization of electromagnetic field distribution area changes with frequency. Based on our design, effective size of electromagnetic field distribution area keeps meeting the subwavelength condition, thus stable phase distribution is gained across broadened bandwidth. It is found by the analysis of the phase gradient metasurface composed of seven units that the metasurface can exhibit anomalous reflection in the wide frequency band of 8.0-20.0 GHz, and the efficiency of abnormal reflection is higher in the range of 10.0-18.0 GHz. The error between the simulation results of abnormal reflection angle and the theoretical result is only - 1.5° to 0.5° after the work of comparison. Therefore, the metasurface designed by the new cross-shaped unit has a good control on the deflection direction of the reflected wave, and shows obvious advantages in widening the bandwidth.

  17. Patient- and cohort-specific dose and risk estimation for abdominopelvic CT: a study based on 100 patients

    NASA Astrophysics Data System (ADS)

    Tian, Xiaoyu; Li, Xiang; Segars, W. Paul; Frush, Donald P.; Samei, Ehsan

    2012-03-01

    The purpose of this work was twofold: (a) to estimate patient- and cohort-specific radiation dose and cancer risk index for abdominopelvic computer tomography (CT) scans; (b) to evaluate the effects of patient anatomical characteristics (size, age, and gender) and CT scanner model on dose and risk conversion coefficients. The study included 100 patient models (42 pediatric models, 58 adult models) and multi-detector array CT scanners from two commercial manufacturers (LightSpeed VCT, GE Healthcare; SOMATOM Definition Flash, Siemens Healthcare). A previously-validated Monte Carlo program was used to simulate organ dose for each patient model and each scanner, from which DLP-normalized-effective dose (k factor) and DLP-normalized-risk index values (q factor) were derived. The k factor showed exponential decrease with increasing patient size. For a given gender, q factor showed exponential decrease with both increasing patient size and patient age. The discrepancies in k and q factors across scanners were on average 8% and 15%, respectively. This study demonstrates the feasibility of estimating patient-specific organ dose and cohort-specific effective dose and risk index in abdominopelvic CT requiring only the knowledge of patient size, gender, and age.

  18. Enhanced Second-Harmonic Generation Using Broken Symmetry III–V Semiconductor Fano Metasurfaces

    DOE PAGES

    Vabishchevich, Polina P.; Liu, Sheng; Sinclair, Michael B.; ...

    2018-01-27

    All-dielectric metasurfaces, two-dimensional arrays of subwavelength low loss dielectric inclusions, can be used not only to control the amplitude and phase of optical beams, but also to generate new wavelengths through enhanced nonlinear optical processes that are free from some of the constraints dictated by the use of bulk materials. Recently, high quality factor (Q) resonances in these metasurfaces have been revealed and utilized for applications such as sensing and lasing. The origin of these resonances stems from the interference of two nanoresonator modes with vastly different Q. Here we show that nonlinear optical processes can be further enhanced bymore » utilizing these high-Q resonances in broken symmetry all-dielectric metasurfaces. As a result, we study second harmonic generation from broken symmetry metasurfaces made from III–V semiconductors and observe nontrivial spectral shaping of second-harmonic and multifold efficiency enhancement induced by high field localization and enhancement inside the nanoresonators.« less

  19. Higher Dietary Cost Is Associated with Higher Diet Quality: A Cross-Sectional Study among Selected Malaysian Adults

    PubMed Central

    Pondor, Ibnteesam

    2017-01-01

    Food price is a determining factor of food choices; however its relationship with diet quality is unclear in Malaysia. This study aimed to examine socio-economic characteristics and daily dietary cost (DDC) in relation to diet quality in the state of Selangor, Malaysia. Dietary intake was assessed using a Food Frequency Questionnaire (FFQ) and diet quality was estimated using a Malaysian Healthy Eating Index (M-HEI). DDC in Malaysian Ringgit (RM) was calculated from dietary intake and national food prices. Linear regression models were fitted to determine associations between DDC and M-HEI scores and predictors of diet quality. The mean M-HEI score of respondents was 61.31 ± 10.88 and energy adjusted DDC was RM10.71/2000 kcal (USD 2.49). The highest quintile of adjusted DDC had higher M-HEI scores for all respondents (Q1: 57.14 ± 10.07 versus Q5: 63.26 ± 11.54, p = 0.001). There were also positive associations between DDC and M-HEI scores for fruits (p < 0.001) and vegetables (p = 0.017) for all respondents. Predictors of diet quality included carbohydrate (β = 0290; p < 0.001) and fat intakes (β = −0.242; p < 0.001) and energy adjusted DDC (β = 0.196; p < 0.001). Higher dietary cost is associated with healthy eating among Malaysian adults. PMID:28926947

  20. Higher Dietary Cost Is Associated with Higher Diet Quality: A Cross-Sectional Study among Selected Malaysian Adults.

    PubMed

    Pondor, Ibnteesam; Gan, Wan Ying; Appannah, Geeta

    2017-09-16

    Food price is a determining factor of food choices; however its relationship with diet quality is unclear in Malaysia. This study aimed to examine socio-economic characteristics and daily dietary cost (DDC) in relation to diet quality in the state of Selangor, Malaysia. Dietary intake was assessed using a Food Frequency Questionnaire (FFQ) and diet quality was estimated using a Malaysian Healthy Eating Index (M-HEI). DDC in Malaysian Ringgit (RM) was calculated from dietary intake and national food prices. Linear regression models were fitted to determine associations between DDC and M-HEI scores and predictors of diet quality. The mean M-HEI score of respondents was 61.31 ± 10.88 and energy adjusted DDC was RM10.71/2000 kcal (USD 2.49). The highest quintile of adjusted DDC had higher M-HEI scores for all respondents (Q1: 57.14 ± 10.07 versus Q5: 63.26 ± 11.54, p = 0.001). There were also positive associations between DDC and M-HEI scores for fruits ( p < 0.001) and vegetables ( p = 0.017) for all respondents. Predictors of diet quality included carbohydrate (β = 0290; p < 0.001) and fat intakes (β = -0.242; p < 0.001) and energy adjusted DDC (β = 0.196; p < 0.001). Higher dietary cost is associated with healthy eating among Malaysian adults.

  1. Response to Growth Hormone Treatment in a Patient with Insulin-Like Growth Factor 1 Receptor Deletion

    PubMed Central

    Mahmoud, Ranim; Naidu, Ajanta; Risheg, Hiba; Kimonis, Virginia

    2017-01-01

    We report a six-year-old boy who presented with short stature, microcephaly, dysmorphic features, and developmental delay and who was identified with a terminal deletion of 15q26.2q26.3 containing the insulin-like growth factor receptor (IGF1R) gene in addition to a terminal duplication of the 4q35.1q35.2 region. We compare our case with other reports of deletions and mutations affecting the IGF1R gene associated with pre-and postnatal growth restriction. We report the dramatic response to growth hormone therapy in this patient which highlights the importance of identifying patients with IGF1R deletion and treating them early. PMID:28720553

  2. Response to Growth Hormone Treatment in a Patient with Insulin-Like Growth Factor 1 Receptor Deletion.

    PubMed

    Mahmoud, Ranim; Naidu, Ajanta; Risheg, Hiba; Kimonis, Virginia

    2017-12-15

    We report a six-year-old boy who presented with short stature, microcephaly, dysmorphic features, and developmental delay and who was identified with a terminal deletion of 15q26.2q26.3 containing the insulin-like growth factor receptor (IGF1R) gene in addition to a terminal duplication of the 4q35.1q35.2 region. We compare our case with other reports of deletions and mutations affecting the IGF1R gene associated with pre-and postnatal growth restriction. We report the dramatic response to growth hormone therapy in this patient which highlights the importance of identifying patients with IGF1R deletion and treating them early.

  3. Coxiella burnetii seroprevalence and associated risk factors in dairy and mixed cattle farms from Ecuador.

    PubMed

    Carbonero, Alfonso; Guzmán, Lucía T; Montaño, Karen; Torralbo, Alicia; Arenas-Montes, Antonio; Saa, Luis R

    2015-03-01

    Q fever is a zoonotic disease caused by Coxiella burnetii, a bacterial agent for which ruminants are the main reservoir. An extensive cross-sectional study to determine the seroprevalence of and associated risk factors for Q fever was performed in dairy and mixed (dairy-beef) cattle herds in Ecuador. A total of 2668 serum samples from 386 herds were analyzed using an ELISA. In addition, a questionnaire with 57 variables related to management, feeding, facilities, biosecurity and animal health was completed for every cattle farm. A Generalized Estimating Equations model was used to determine the factors associated with C. burnetii seropositivity. The true prevalence of C. burnetii seropositivity in dairy and mixed cattle from Ecuador reached 12.6% (CI95%: 11.3-13.9%). The herd prevalence was 46.9% (181/386) (CI95%: 41.9-51.9%), and the within herd prevalence ranged between 8% and 100% (mean: 25.0%; Q1: 12.5%, Q2: 25.0%, Q3: 37.5%). Four factors were included in the GEE model for C. burnetii seropositivity: age of the cattle (OR: 1.01; CI95%: 1.006-1.014), feeding of calves with milk replacers (OR: 1.94; CI95%: 1.1-3.3), bovine respiratory syncytial virus seropositivity (OR: 1.54; CI95%: 1.1-2.3), and disinfection of the umbilical cord (OR: 0.60; CI95%: 0.4-0.9). Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Persian adaptation of a questionnaire of environmental risk factors in multiple sclerosis (EnvIMS-Q).

    PubMed

    Sahraian, Mohammad Ali; Naghshineh, Hoda; Shati, Mohsen; Jahromi, Soodeh Razeghi; Rezaei, Niloofar

    2016-11-01

    It seems that gene-environment interaction play most important role in Multiple Sclerosis development. Increasing the incidence and prevalence of MS during the recent decades in the low prevalence area such as Iran is explained better by environment factors. Environmental Risk Factors in Multiple Sclerosis (the 'EnvIMS-Q') is a 6-page self-administered questionnaire for case control studies. the objectives of study are validation and adaptation of the EnvIMS-Q' then development of a Persian version for case control studies in Persian population. This questionnaire translated literally and in culturally relevant form, then content validation process was done by three groups' experts. According to giving rating to each item, each section and the whole instrument, we calculated their content validation indexes and also added some new questions and a new section to EnvIMS-Q. Finally, we analyzed repeatability of the answers within a 4 weeks interval. Relevancy and clarity indexes of all items were more than 80%. Scale relevancy index equaled 99% and scale clarity index equaled 97%. Repeatability of most items was acceptable. the use of standardized validated questionnaires will assist the researchers to perform local studies on the role of environmental factors on the basis of reliable data. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Patterns of anger expression among middle-aged Korean women: Q methodology.

    PubMed

    Lee, Yong Mi; Kim, Geun Myun

    2012-12-01

    The purpose of this study was to identify the characteristics of anger expression in middle-aged Korean women by categorizing their patterns of expression while considering the complexity and multidimensionality of anger, and by investigating the characteristics relative to the patterns. The research design was a descriptive design using Q methodology, which is a method of measuring subjectivity. A convenience sample of 42 participants aged 40-60 years and living in the community in Korea was recruited. The PC-QUANL software program (a factor analysis program for the Q technique) was used to analyze the Q-sort data. Four factors were extracted that described different expressions of anger among middle-aged Korean women; these factors explained 50.1% of the total variance. The frames of reference of the four factors were a) direct diversion, b) silent masking with remaining anger, c) self digestion, and d) controlling anger with objectification. In this study has identified patterns and characteristics of anger expression among middle-aged Korean women were identified, which will aid the development of effective anger-management programs for controlling anger in this population. In future studies, it would be helpful to investigate how the patterns of anger expression established herein are associated with specific health problems such as cardiovascular disorder and cancer.

  6. Development and Validation Study of the Internet Overuse Screening Questionnaire

    PubMed Central

    Lee, Han-Kyeong; Lee, Hae-Woo; Han, Joo Hyun; Park, Subin; Ju, Seok-Jin; Choi, Kwanwoo; Lee, Ji Hyeon; Jeon, Hong Jin

    2018-01-01

    Objective Concerns over behavioral and emotional problems caused by excessive internet usage have been developed. This study intended to develop and a standardize questionnaire that can efficiently identify at-risk internet users through their internet usage habits. Methods Participants (n=158) were recruited at six I-will-centers located in Seoul, South Korea. From the initial 36 questionnaire item pool, 28 preliminary items were selected through expert evaluation and panel discussions. The construct validity, internal consistency, and concurrent validity were examined. We also conducted Receiver Operating Curve (ROC) analysis to assess diagnostic ability of the Internet Overuse Screening-Questionnaire (IOS-Q). Results The exploratory factor analysis yielded a five factor structure. Four factors with 17 items remained after items that had unclear factor loading were removed. The Cronbach’s alpha for the IOS-Q total score was 0.91, and test-retest reliability was 0.72. The correlation between Young’s internet addiction scale and K-scale supported concurrent validity. ROC analysis showed that the IOS-Q has superior diagnostic ability with the Area Under the Curve of 0.87. At the cut-off point of 25.5, the sensitivity was 0.93 and specificity was 0.86. Conclusion Overall, this study supports the use of IOS-Q for internet addiction research and for screening high-risk individuals. PMID:29669406

  7. Tensor form factor for the D → π(K) transitions with Twisted Mass fermions.

    NASA Astrophysics Data System (ADS)

    Lubicz, Vittorio; Riggio, Lorenzo; Salerno, Giorgio; Simula, Silvano; Tarantino, Cecilia

    2018-03-01

    We present a preliminary lattice calculation of the D → π and D → K tensor form factors fT (q2) as a function of the squared 4-momentum transfer q2. ETMC recently computed the vector and scalar form factors f+(q2) and f0(q2) describing D → π(K)lv semileptonic decays analyzing the vector current and the scalar density. The study of the weak tensor current, which is directly related to the tensor form factor, completes the set of hadronic matrix element regulating the transition between these two pseudoscalar mesons within and beyond the Standard Model where a non-zero tensor coupling is possible. Our analysis is based on the gauge configurations produced by the European Twisted Mass Collaboration with Nf = 2 + 1 + 1 flavors of dynamical quarks. We simulated at three different values of the lattice spacing and with pion masses as small as 210 MeV and with the valence heavy quark in the mass range from ≃ 0.7 mc to ≃ 1.2mc. The matrix element of the tensor current are determined for a plethora of kinematical conditions in which parent and child mesons are either moving or at rest. As for the vector and scalar form factors, Lorentz symmetry breaking due to hypercubic effects is clearly observed in the data. We will present preliminary results on the removal of such hypercubic lattice effects.

  8. Recent RF Experiments and Application of RF Waves to Real-Time Control of Safety Factor Profile in JT-60U

    NASA Astrophysics Data System (ADS)

    Suzuki, T.; Isayama, A.; Ide, S.; Fujita, T.; Oikawa, T.; Sakata, S.; Sueoka, M.; Hosoyama, H.; JT-60 Team

    2005-09-01

    Two topics of applications of RF waves to current profile control in JT-60U are presented; application of lower-hybrid (LH) waves to safety factor profile control and electron cyclotron (EC) waves to neo-classical tearing mode (NTM) control. A real-time control system of safety factor (q) profile was developed. This system, for the first time, enables 1) real time evaluation of q profile using local magnetic pitch angle measurement by motional Stark effect (MSE) diagnostic and 2) control of current drive (CD) location (ρCD) by controlling the parallel refractive index N∥ of LH waves through control of phase difference (Δφ) of LH waves between multi-junction launcher modules. The method for real-time q profile evaluation was newly developed, without time-consuming reconstruction of equilibrium, so that the method requires less computational time. Safety factor profile by the real-time calculation agrees well with that by equilibrium reconstruction with MSE. The control system controls ρCD through Δφ in such a way to decrease the largest residual between the real-time evaluated q profile q(r) and its reference profile qref(r). The real-time control system was applied to a positive shear plasma (q(0)˜1). The reference q profile was set to monotonic positive shear profile having qref(0)=1.3. The real-time q profile approached to the qref(r) during application of real-time control, and was sustained for 3s, which was limited by the duration of the injected LH power. Temporal evolution of current profile was consistent with relaxation of inductive electric field induced by theoretical LH driven current. An m/n=3/2 NTM that appeared at βN˜3 was completely stabilized by ECCD applied to a fully-developed NTM. Precise ECCD at NTM island was essential for the stabilization. ECCD that was applied to resonant rational surface (q=3/2) before an NTM onset suppressed appearance of NTM. In order to keep NTM intensity below a level, ECCD before the mode onset was more effective than that after mode saturation.

  9. Design of a metasurface-based dual-band Terahertz perfect absorber with very high Q-factors for sensing applications

    NASA Astrophysics Data System (ADS)

    Janneh, M.; De Marcellis, A.; Palange, E.; Tenggara, A. T.; Byun, D.

    2018-06-01

    We report on a novel very high Q-factor dual-band Terahertz perfect absorber composed of a metasurface located on top of a flexible polyimide spacer deposited on a silver ground layer. The metasurface is a 2D-array of plasmonic nanoantennas with the shape of two concentric square rings and a cylinder positioned at their centre. By performing numerical simulations, we studied the polarisation insensitive electromagnetic response of the absorber for incident angles varying from 0° up to ±30°. The two resonant modes centred at f1 = 1.80 THz and f2 = 2.26 THz have Q-factors Q(f1) = 120 and Q(f2) = 94 and absorption coefficients A(f1) = 99 . 8 % and A(f2) = 99 . 6%. Moreover, we investigated how the resonant mode frequencies change with the refractive index and thickness of transparent analytes adsorbed on the metasurface. In terms of the Refractive Index Units (RIU), we obtained sensitivities equal to 187.5 GHz/RIU and 360 GHz/RIU for the f1 and f2 resonance frequencies, respectively, and figure of merits up to FOM = 19 . 1 and FOM∗ = 431. These results make the dual-band absorber to be employed as a sensing device able to detect the presence and/or the physical/chemical modifications of the adsorbed analytes. Moreover, we investigated the dependence of the sensitivity as a function of slight modifications of the metasurface nanoantenna shape, demonstrating that a more homogeneous distribution of the electric field intensity on the metasurface improves the sensitivity of the absorber without affecting the Q-factors.

  10. Expanding the clinical spectrum of chromosome 15q26 terminal deletions associated with IGF-1 resistance.

    PubMed

    O'Riordan, Aisling M; McGrath, Niamh; Sharif, Farhana; Murphy, Nuala P; Franklin, Orla; Lynch, Sally Ann; O'Grady, Michael J

    2017-01-01

    Haploinsufficiency of the insulin-like growth factor-1 receptor (IGF1R) gene on chromosome 15q26.3 is associated with impaired prenatal and postnatal growth, developmental delay, dysmorphic features and skeletal abnormalities. Terminal deletions of chromosome 15q26 arising more proximally may also be associated with congenital heart disease, epilepsy, diaphragmatic hernia and renal anomalies. We report three additional cases of 15q26 terminal deletions with novel features which may further expand the spectrum of this rarely reported contiguous gene syndrome. Phenotypic features including neonatal lymphedema, aplasia cutis congenita and aortic root dilatation have not been reported previously. Similarly, laboratory features of insulin-like growth factor 1 (IGF-1) resistance are described, including markedly elevated IGF-1 of up to +4.7 SDS. In one patient, the elevated IGF-1 declined over time and this coincided with a period of spontaneous growth acceleration. Deletions of 15q26 are a potential risk factor for aortic root dilatation, neonatal lymphedema and aplasia cutis in addition to causing growth restriction. What is Known: • Terminal deletions of chromosome 15q26 are associated with impaired prenatal and postnatal growth, developmental delay, dysmorphic features and skeletal abnormalities. What is New: • Neonatal lymphedema, aplasia cutis congenita and aortic root dilatation have not been previously described in 15q26 terminal deletions and may represent novel features. • IGF-1 levels may be increased up to 4.7 SDS.

  11. Maternity staff perspectives regarding resource demands of breastfeeding supportive practices in accordance with the Baby-Friendly Hospital Initiative accreditation: a Q methodology approach.

    PubMed

    Huang, Chiu-Mieh; Hung, Wei-Shu; Lai, Jung-Nien; Kao, Yu-Hsiu; Wang, Ching-Ling; Guo, Jong-Long

    2016-06-01

    To explore the resource demands of implementing the Baby-Friendly Hospital Initiative among maternity staff. Implementing the Baby-Friendly Hospital Initiative is the most recognized global strategy for ensuring that hospital routines support breastfeeding. The maternity services of Baby-Friendly Hospital Initiative accredited hospitals are evaluated according to the Ten Steps to Successful Breastfeeding. Q methodology was applied to investigate the perspectives of 60 maternity staff in Northern Taiwan. Data were collected from May - December 2014. An online Q-sort platform was designed for the participants to perform sorting. The Q-sorts were subjected to factor analysis by using PQ Method software. Factors were extracted using principal component analysis with a varimax rotation. A combination of eigenvalues and a scree plot were employed to determine the number of retained factors. Four factors retained in the final model accounted for 56% of the total variance: (1) emphasis on implementing an institutional policy; (2) emphasis on providing supportive practices for breastfeeding mothers; (3) emphasis on establishing continual breastfeeding support; and (4) emphasis on managing breastfeeding supportive practices concerning a designated time period. The participants that were associated with Factors 1 and 3 emphasized the necessity of allocating resources to Steps 1, 2 and 10 of the Ten Steps. The participants associated with Factors 2 and 4 emphasized allocating resources to Steps 2-5 and 7. This study revealed the various perspectives of maternity staff regarding the resource demands of implementing the Baby-Friendly Hospital Initiative. These perspectives may serve as a reference for decision-makers in prioritizing resource allocation. © 2016 John Wiley & Sons Ltd.

  12. Role of tumour necrosis factor (TNF)-α and TNFRSF1A R92Q mutation in the pathogenesis of TNF receptor-associated periodic syndrome and multiple sclerosis

    PubMed Central

    Caminero, A; Comabella, M; Montalban, X

    2011-01-01

    It has long been known that tumour necrosis factor (TNF)/TNFRSF1A signalling is involved in the pathophysiology of multiple sclerosis (MS). Different genetic and clinical findings over the last few years have generated renewed interest in this relationship. This paper provides an update on these recent findings. Genome-wide association studies have identified the R92Q mutation in the TNFRSF1A gene as a genetic risk factor for MS (odds ratio 1·6). This allele, which is also common in the general population and in other inflammatory conditions, therefore only implies a modest risk for MS and provides yet another piece of the puzzle that defines the multiple genetic risk factors for this disease. TNFRSF1A mutations have been associated with an autoinflammatory disease known as TNF receptor-associated periodic syndrome (TRAPS). Clinical observations have identified a group of MS patients carrying the R92Q mutation who have additional TRAPS symptoms. Hypothetically, the co-existence of MS and TRAPS or a co-morbidity relationship between the two could be mediated by this mutation. The TNFRSF1A R92Q mutation behaves as a genetic risk factor for MS and other inflammatory diseases, including TRAPS. Nevertheless, this mutation does not appear to be a severity marker of the disease, neither modifying the clinical progression of MS nor its therapeutic response. An alteration in TNF/TNFRS1A signalling may increase proinflammatory signals; the final clinical phenotype may possibly be determined by other genetic or environmental modifying factors that have not yet been identified. PMID:22059991

  13. Axial-vector form factors of the nucleon from lattice QCD

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gupta, Rajan; Jang, Yong-Chull; Lin, Huey-Wen

    In this paper, we present results for the form factors of the isovector axial vector current in the nucleon state using large scale simulations of lattice QCD. The calculations were done using eight ensembles of gauge configurations generated by the MILC collaboration using the HISQ action with 2 + 1 + 1 dynamical flavors. These ensembles span three lattice spacings a ≈ 0.06 , 0.09, and 0.12 fm and light-quark masses corresponding to the pion masses M π ≈ 135, 225, and 310 MeV. High-statistics estimates allow us to quantify systematic uncertainties in the extraction of G A (Q 2)more » and the induced pseudoscalar form factor G P(Q 2) . We perform a simultaneous extrapolation in the lattice spacing, lattice volume and light-quark masses of the axial charge radius r A data to obtain physical estimates. Using the dipole ansatz to fit the Q 2 behavior we obtain r A | dipole = 0.49(3) fm , which corresponds to M A = 1.39(9) GeV , and is consistent with M A = 1.35(17) GeV obtained by the miniBooNE collaboration. The estimate obtained using the z -expansion is r A | z - expansion = 0.46(6) fm, and the combined result is r A | combined = 0.48(4) fm. Analysis of the induced pseudoscalar form factor G P (Q 2) yields low estimates for g* P and g πNN compared to their phenomenological values. To understand these, we analyze the partially conserved axial current (PCAC) relation by also calculating the pseudoscalar form factor. Lastly, we find that these low values are due to large deviations in the PCAC relation between the three form factors, and in the pion-pole dominance hypothesis.« less

  14. Axial-vector form factors of the nucleon from lattice QCD

    DOE PAGES

    Gupta, Rajan; Jang, Yong-Chull; Lin, Huey-Wen; ...

    2017-12-04

    In this paper, we present results for the form factors of the isovector axial vector current in the nucleon state using large scale simulations of lattice QCD. The calculations were done using eight ensembles of gauge configurations generated by the MILC collaboration using the HISQ action with 2 + 1 + 1 dynamical flavors. These ensembles span three lattice spacings a ≈ 0.06 , 0.09, and 0.12 fm and light-quark masses corresponding to the pion masses M π ≈ 135, 225, and 310 MeV. High-statistics estimates allow us to quantify systematic uncertainties in the extraction of G A (Q 2)more » and the induced pseudoscalar form factor G P(Q 2) . We perform a simultaneous extrapolation in the lattice spacing, lattice volume and light-quark masses of the axial charge radius r A data to obtain physical estimates. Using the dipole ansatz to fit the Q 2 behavior we obtain r A | dipole = 0.49(3) fm , which corresponds to M A = 1.39(9) GeV , and is consistent with M A = 1.35(17) GeV obtained by the miniBooNE collaboration. The estimate obtained using the z -expansion is r A | z - expansion = 0.46(6) fm, and the combined result is r A | combined = 0.48(4) fm. Analysis of the induced pseudoscalar form factor G P (Q 2) yields low estimates for g* P and g πNN compared to their phenomenological values. To understand these, we analyze the partially conserved axial current (PCAC) relation by also calculating the pseudoscalar form factor. Lastly, we find that these low values are due to large deviations in the PCAC relation between the three form factors, and in the pion-pole dominance hypothesis.« less

  15. Versatile application of indirect Fourier transformation to structure factor analysis: from X-ray diffraction of molecular liquids to small angle scattering of protein solutions.

    PubMed

    Fukasawa, Toshiko; Sato, Takaaki

    2011-02-28

    We highlight versatile applicability of a structure-factor indirect Fourier transformation (IFT) technique, hereafter called SQ-IFT. The original IFT aims at the pair distance distribution function, p(r), of colloidal particles from small angle scattering of X-rays (SAXS) and neutrons (SANS), allowing the conversion of the experimental form factor, P(q), into a more intuitive real-space spatial autocorrelation function. Instead, SQ-IFT is an interaction potential model-free approach to the 'effective' or 'experimental' structure factor to yield the pair correlation functions (PCFs), g(r), of colloidal dispersions like globular protein solutions for small-angle scattering data as well as the radial distribution functions (RDFs) of molecular liquids in liquid diffraction (LD) experiments. We show that SQ-IFT yields accurate RDFs of liquid H(2)O and monohydric alcohol reflecting their local intermolecular structures, in which q-weighted structure function, qH(q), conventionally utilized in many LD studies out of necessity of performing direct Fourier transformation, is no longer required. We also show that SQ-IFT applied to theoretically calculated structure factors for uncharged and charged colloidal dispersions almost perfectly reproduces g(r) obtained as a solution of the Ornstein-Zernike (OZ) equation. We further demonstrate the relevance of SQ-IFT in its practical applications, using SANS effective structure factors of lysozyme solutions reported in recent literatures which revealed the equilibrium cluster formation due to coexisting long range electrostatic repulsion and short range attraction between the proteins. Finally, we present SAXS experiments on human serum albumin (HSA) at different ionic strength and protein concentration, in which we discuss the real space picture of spatial distributions of the proteins via the interaction potential model-free route.

  16. An integrated quality function deployment and capital budgeting methodology for occupational safety and health as a systems thinking approach: the case of the construction industry.

    PubMed

    Bas, Esra

    2014-07-01

    In this paper, an integrated methodology for Quality Function Deployment (QFD) and a 0-1 knapsack model is proposed for occupational safety and health as a systems thinking approach. The House of Quality (HoQ) in QFD methodology is a systematic tool to consider the inter-relationships between two factors. In this paper, three HoQs are used to consider the interrelationships between tasks and hazards, hazards and events, and events and preventive/protective measures. The final priority weights of events are defined by considering their project-specific preliminary weights, probability of occurrence, and effects on the victim and the company. The priority weights of the preventive/protective measures obtained in the last HoQ are fed into a 0-1 knapsack model for the investment decision. Then, the selected preventive/protective measures can be adapted to the task design. The proposed step-by-step methodology can be applied to any stage of a project to design the workplace for occupational safety and health, and continuous improvement for safety is endorsed by the closed loop characteristic of the integrated methodology. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Tidal dissipation in the Moon. Learning from the "incorrect" frequency dependence measured by the LLR

    NASA Astrophysics Data System (ADS)

    Efroimsky, M.

    2012-09-01

    It was demonstrated back in 2001 that fitting of the LLR data results in the quality factor Q of the Moon scaling as the frequency ξ to a negative power [8]: Q ˜ ξp , where p = -0.19 . (1) At the same time, numerous measurements by various seismological teams agree on the exponent being positive, not negative [4]. The positive sign of the exponent stems also from geodetic measurements [1], and it finds its explanation within the theory of friction in minerals [5]. On all these grounds, the aforementioned finding by the LLR team appears to be implausible and to disagree with the conventional wisdom of solid state mechanics and seismology. A later reexamination in [9] rendered a less upsetting value, p = -0.09 , which was still negative and still seemed to contradict our knowledge of microphysical processes in solids. The authors later wrote [10]: "There is a weak dependence of tidal specific dissipation Q on period. The Q increases from ˜ 30 at a month to ˜ 35 at one year. Q for rock is expected to have a weak dependence on tidal period, but it is expected to decrease with period rather than increase. The frequency dependence of Q deserves further attention and should be improved." A possible explanation of this paradox comes from the observation that the LLR measurements provided information on the tidal and not seismic dissipation. The difference between these two processes comes from self-gravitation of the celestial body. To address the problem accurately, one has to calculate the tidal factors kl sin ɛl showing up in the Darwin-Kaula expansion for the tidal torque or force. Here kl is the degree-l Love number, while ɛl is the appropriate tidal lag. Sometimes sin ɛl is denoted with 1/Q , which is not recommended, because this notation does not distinguish between the tidal reaction appropriate to harmonics of different degree. This notation also puts one at risk of confusing the tidal damping with the seismic damping, two process that have much in common but are nevertheless different [2, 3]. The factors kl sin ɛl are functions of the tidal modes ωlmpq , where lmpq are integers used to number the modes. (The tidal modes can be either positive or negative, while the appropriate tidal forcing frequencies in the mantle, ξlmpq = | ωlmpq | , are positively defined.) So the lmpq term in the expansion of tide is proportional to kl(ωlmpq) sin ɛl(ωlmpq) . An accurate calculation demonstrates that for realistic rheologies the tidal factors kl sin ɛl have a maximum at a frequency, which is (for not too large bodies) about the inverse Maxwell time [2, 3]. In the zerofrequency limit, the factors go smoothly through nil and change their sign, a natural behaviour saving the theory from an infinite torque or force at a resonance crossing. As the small negative exponent was derived from LLR observations over periods of a month to a year, we see that the appropriate frequencies were close to or slightly below the frequency at which the factor k2 sin ɛ2 has its peak. Taken that the said frequency is not very different from the inverse Maxwell time, we estimate the typical viscosity η of the Lunar mantle as2 Such a low viscosity may indicate that the lower lunar mantle contains a high percentage of partial melt. This interpretation goes along with the model developed in [6] and advocated later in [8] and [10]. It also agrees with the recent model offered in [7].

  18. Antibody neutralization of cell-surface gC1qR/HABP1/SF2-p32 prevents lamellipodia formation and tumorigenesis

    PubMed Central

    Kim, Beom-Chan; Hwang, Hyun-Jung; An, Hyoung-Tae; Lee, Hyun; Park, Jun-Sub; Hong, Jin; Ko, Jesang; Kim, Chungho; Lee, Jae-Seon; Ko, Young-Gyu

    2016-01-01

    We previously demonstrated that cell-surface gC1qR is a key regulator of lamellipodia formation and cancer metastasis. Here, we screened a monoclonal mouse antibody against gC1qR to prevent cell migration by neutralizing cell-surface gC1qR. The anti-gC1qR antibody prevented growth factor-stimulated lamellipodia formation, cell migration and focal adhesion kinase activation by inactivating receptor tyrosine kinases (RTKs) in various cancer cells such as A549, MDA-MB-231, MCF7 and HeLa cells. The antibody neutralization of cell-surface gC1qR also inhibited angiogenesis because the anti-gC1qR antibody prevented growth factor-stimulated RTK activation, lamellipodia formation, cell migration and tube formation in HUVEC. In addition, we found that A549 tumorigenesis was reduced in a xenograft mouse model by following the administration of the anti-gC1qR antibody. With these data, we can conclude that the antibody neutralization of cell-surface gC1qR could be a good therapeutic strategy for cancer treatment. PMID:27363031

  19. Effective dose equivalent on the ninth Shuttle--Mir mission (STS-91)

    NASA Technical Reports Server (NTRS)

    Yasuda, H.; Badhwar, G. D.; Komiyama, T.; Fujitaka, K.

    2000-01-01

    Organ and tissue doses and effective dose equivalent were measured using a life-size human phantom on the ninth Shuttle-Mir Mission (STS-91, June 1998), a 9.8-day spaceflight at low-Earth orbit (about 400 km in altitude and 51.65 degrees in inclination). The doses were measured at 59 positions using a combination of thermoluminescent dosimeters of Mg(2)SiO(4):Tb (TDMS) and plastic nuclear track detectors (PNTD). In correcting the change in efficiency of the TDMS, it was assumed that reduction of efficiency is attributed predominantly to HZE particles with energy greater than 100 MeV nucleon(-1). A conservative calibration curve was chosen for determining LET from the PNTD track-formation sensitivities. The organ and tissue absorbed doses during the mission ranged from 1.7 to 2.7 mGy and varied by a factor of 1.6. The dose equivalent ranged from 3.4 to 5.2 mSv and varied by a factor of 1.5 on the basis of the dependence of Q on LET in the 1990 recommendations of the ICRP. The effective quality factor (Q(e)) varied from 1.7 to 2.4. The dose equivalents for several radiation-sensitive organs, such as the stomach, lung, gonad and breast, were not significantly different from the skin dose equivalent (H(skin)). The effective dose equivalent was evaluated as 4.1 mSv, which was about 90% of the H(skin).

  20. Chemically etched ultrahigh-Q wedge-resonator on a silicon chip

    NASA Astrophysics Data System (ADS)

    Lee, Hansuek; Chen, Tong; Li, Jiang; Yang, Ki Youl; Jeon, Seokmin; Painter, Oskar; Vahala, Kerry J.

    2012-06-01

    Ultrahigh-Q optical resonators are being studied across a wide range of fields, including quantum information, nonlinear optics, cavity optomechanics and telecommunications. Here, we demonstrate a new resonator with a record Q-factor of 875 million for on-chip devices. The fabrication of our device avoids the requirement for a specialized processing step, which in microtoroid resonators has made it difficult to control their size and achieve millimetre- and centimetre-scale diameters. Attaining these sizes is important in applications such as microcombs and potentially also in rotation sensing. As an application of size control, stimulated Brillouin lasers incorporating our device are demonstrated. The resonators not only set a new benchmark for the Q-factor on a chip, but also provide, for the first time, full compatibility of this important device class with conventional semiconductor processing. This feature will greatly expand the range of possible `system on a chip' functions enabled by ultrahigh-Q devices.

  1. Use of mechanistic simulations as a quantitative risk-ranking tool within the quality by design framework.

    PubMed

    Stocker, Elena; Toschkoff, Gregor; Sacher, Stephan; Khinast, Johannes G

    2014-11-20

    The purpose of this study is to evaluate the use of computer simulations for generating quantitative knowledge as a basis for risk ranking and mechanistic process understanding, as required by ICH Q9 on quality risk management systems. In this specific publication, the main focus is the demonstration of a risk assessment workflow, including a computer simulation for the generation of mechanistic understanding of active tablet coating in a pan coater. Process parameter screening studies are statistically planned under consideration of impacts on a potentially critical quality attribute, i.e., coating mass uniformity. Based on computer simulation data the process failure mode and effects analysis of the risk factors is performed. This results in a quantitative criticality assessment of process parameters and the risk priority evaluation of failure modes. The factor for a quantitative reassessment of the criticality and risk priority is the coefficient of variation, which represents the coating mass uniformity. The major conclusion drawn from this work is a successful demonstration of the integration of computer simulation in the risk management workflow leading to an objective and quantitative risk assessment. Copyright © 2014. Published by Elsevier B.V.

  2. Can we use the q-Gaussian of ambient noise fluctuations as a vulnerability index? A case study in Cultural Heritage buildings

    NASA Astrophysics Data System (ADS)

    Vallianatos, Filippos; Koutalonis, Ioannis; Moisidi, Margarita; Chatzopoulos, Georgios

    2018-05-01

    In this work we study in terms of Tsallis statistical mechanics the properties of microtremors' fluctuations in two church bell towers, which are monuments of cultural heritage, in the city of Chania (Crete, Greece). We have shown that fluctuations of ambient vibrations recordings in the Church tower bells follow a q-Gaussian distribution. The behavior of Tsallis q parameter with the level (high) of the measuring point within the tower and the amplification factors at that points as extracted from horizontal-to-vertical (HVSR) spectral ratios are presented and discussed. Since q decreases as the amplification factor increases, we could suggest q as a vulnerability index, where, as q decreases approaching unity, then the structural system is getting more vulnerable. The latter approach suggests that introducing ideas of Tsallis statistics could be useful in characterizing extremely complex processes as that governed the estimation of seismic vulnerability in which a multidisciplinary approach is required.

  3. Tokamak Operation with Safety Factor q 95 < 2 via Control of MHD Stability

    DOE PAGES

    Piovesan, Paolo; Hanson, Jeremy M.; Martin, Piero; ...

    2014-07-24

    Magnetic feedback control of the resistive-wall mode has enabled DIII-D to access stable operation at safety factor q95 = 1:9 in divertor plasmas for 150 instability growth times. Magnetohydrodynamic stability sets a hard, disruptive limit on the minimum edge safety factor achievable in a tokamak, or on the maximum plasma current at given toroidal magnetic eld. In tokamaks with a divertor, the limit occurs at q95 = 2, as con rmed in DIII-D. Since the energy con cement time scales linearly with current, this also bounds the performance of a fusion reactor. DIII-D has overcome this limit, opening a wholemore » new high-current regime not accessible before. This result brings signi cant possible bene ts in terms of fusion performance, but it also extends resistive wall mode physics and its control to conditions never explored before. In present experiments, q95 < 2 operation is eventually halted by voltage limits reached in the feedback power supplies, not by intrinsic physics issues. Improvements to power supplies and to control algorithms have the potential to further extend this regime.« less

  4. The non-resonant kink modes triggering strong sawtooth-like crashes in the EAST tokamak

    NASA Astrophysics Data System (ADS)

    Li, Erzhong; Igochine, V.; Dumbrajs, O.; Xu, L.; Chen, K.; Shi, T.; Hu, L.

    2014-12-01

    Evolution of the safety factor (q) profile during L-H transitions in the Experimental Advanced Superconducting Tokamak (EAST) was accompanied by strong core crashes prior to regular sawtooth behavior. These crashes appeared in the absence of q = 1 (q is the safety factor) rational surface inside the plasma. Analysis indicates that the m/n = 2/1 tearing mode is destabilized and phase-locked with the m/n = 1/1 non-resonant kink mode (the q = 1 rational surface is absent) due to the self-consistent evolution of plasma profiles as the L-H transition occurs (m and n are the poloidal and toroidal mode numbers, respectively). The growing m/n = 1/1 mode destabilizes the m/n = 2/2 kink mode which eventually triggers the strong crash due to an anomalous heat conductivity, as predicted by the transport model of stochastic magnetic fields using experimental parameters. It is also shown that the magnetic topology changes with the amplitude of m/n = 2/2 mode and the value of center safety factor in a reasonable range.

  5. Measurement of the generalized form factors near threshold via γ*p→nπ+ at high Q2

    NASA Astrophysics Data System (ADS)

    Park, K.; Gothe, R. W.; Adhikari, K. P.; Adikaram, D.; Anghinolfi, M.; Baghdasaryan, H.; Ball, J.; Battaglieri, M.; Batourine, V.; Bedlinskiy, I.; Bennett, R. P.; Biselli, A. S.; Bookwalter, C.; Boiarinov, S.; Branford, D.; Briscoe, W. J.; Brooks, W. K.; Burkert, V. D.; Carman, D. S.; Celentano, A.; Chandavar, S.; Charles, G.; Cole, P. L.; Contalbrigo, M.; Crede, V.; D'Angelo, A.; Daniel, A.; Dashyan, N.; De Vita, R.; De Sanctis, E.; Deur, A.; Djalali, C.; Doughty, D.; Dupre, R.; El Alaoui, A.; El Fassi, L.; Eugenio, P.; Fedotov, G.; Fradi, A.; Gabrielyan, M. Y.; Gevorgyan, N.; Gilfoyle, G. P.; Giovanetti, K. L.; Girod, F. X.; Goetz, J. T.; Gohn, W.; Golovatch, E.; Graham, L.; Griffioen, K. A.; Guidal, M.; Guo, L.; Hafidi, K.; Hakobyan, H.; Hanretty, C.; Heddle, D.; Hicks, K.; Holtrop, M.; Hyde, C. E.; Ilieva, Y.; Ireland, D. G.; Ishkhanov, B. S.; Isupov, E. L.; Jenkins, D.; Jo, H. S.; Joo, K.; Kalantarians, N.; Khandaker, M.; Khetarpal, P.; Kim, A.; Kim, W.; Klein, A.; Klein, F. J.; Kubarovsky, A.; Kubarovsky, V.; Kuhn, S. E.; Kuleshov, S. V.; Kvaltine, N. D.; Livingston, K.; Lu, H. Y.; MacGregor, I. J. D.; Markov, N.; Mayer, M.; McKinnon, B.; Mestayer, M. D.; Meyer, C. A.; Mineeva, T.; Mirazita, M.; Mokeev, V.; Moutarde, H.; Munevar, E.; Nadel-Turonski, P.; Nasseripour, R.; Niccolai, S.; Niculescu, G.; Niculescu, I.; Osipenko, M.; Ostrovidov, A. I.; Paolone, M.; Pappalardo, L.; Paremuzyan, R.; Park, S.; Pereira, S. Anefalos; Phelps, E.; Pisano, S.; Pogorelko, O.; Pozdniakov, S.; Price, J. W.; Procureur, S.; Prok, Y.; Ricco, G.; Rimal, D.; Ripani, M.; Ritchie, B. G.; Rosner, G.; Rossi, P.; Sabatié, F.; Saini, M. S.; Salgado, C.; Schott, D.; Schumacher, R. A.; Seraydaryan, H.; Sharabian, Y. G.; Smith, E. S.; Smith, G. D.; Sober, D. I.; Sokhan, D.; Stepanyan, S. S.; Stepanyan, S.; Stoler, P.; Strakovsky, I. I.; Strauch, S.; Taiuti, M.; Tang, W.; Taylor, C. E.; Tian, Y.; Tkachenko, S.; Trivedi, A.; Ungaro, M.; Vernarsky, B.; Vlassov, A. V.; Voutier, E.; Watts, D. P.; Weygand, D. P.; Wood, M. H.; Zachariou, N.; Zhao, B.; Zhao, Z. W.

    2012-03-01

    We report the first extraction of the pion-nucleon multipoles near the production threshold for the nπ+ channel at relatively high momentum transfer (Q2 up to 4.2 GeV2). The dominance of the s-wave transverse multipole (E0+), expected in this region, allowed us to access the generalized form factor G1 within the light-cone sum-rule (LCSR) framework as well as the axial form factor GA. The data analyzed in this work were collected by the nearly 4π CEBAF Large Acceptance Spectrometer (CLAS) using a 5.754-GeV electron beam on a proton target. The differential cross section and the π-N multipole E0+/GD were measured using two different methods, the LCSR and a direct multipole fit. The results from the two methods are found to be consistent and almost Q2 independent.

  6. Testicular differentiation factor SF-1 is required for human spleen development

    PubMed Central

    Zangen, David; Kaufman, Yotam; Banne, Ehud; Weinberg-Shukron, Ariella; Abulibdeh, Abdulsalam; Garfinkel, Benjamin P.; Dweik, Dima; Kanaan, Moein; Camats, Núria; Flück, Christa; Renbaum, Paul; Levy-Lahad, Ephrat

    2014-01-01

    The transcription factor steroidogenic factor 1 (SF-1; also known as NR5A1) is a crucial mediator of both steroidogenic and nonsteroidogenic tissue differentiation. Mutations within SF1 underlie different disorders of sexual development (DSD), including sex reversal, spermatogenic failure, ovarian insufficiency, and adrenocortical deficiency. Here, we identified a recessive mutation within SF1 that resulted in a substitution of arginine to glutamine at codon 103 (R103Q) in a child with both severe 46,XY-DSD and asplenia. The R103Q mutation decreased SF-1 transactivation of TLX1, a transcription factor that has been shown to be essential for murine spleen development. Additionally, the SF1 R103Q mutation impaired activation of steroidogenic genes, without affecting synergistic SF-1 and sex-determining region Y (SRY) coactivation of the testis development gene SOX9. Together, our data provide evidence that SF-1 is required for spleen development in humans via transactivation of TLX1 and that mutations that only impair steroidogenesis, without altering the SF1/SRY transactivation of SOX9, can lead to 46,XY-DSD. PMID:24905461

  7. Cognitive and Functional Correlates of NPI-Q Scores and Symptom Clusters in Mildly Demented Alzheimer Patients.

    PubMed

    Travis Seidl, Jennifer N; Massman, Paul J

    2016-01-01

    Previous research has demonstrated an association between the emotional and behavioral symptoms of dementia, known as neuropsychiatric symptoms, and cognitive and functional decline among patients with Alzheimer disease (AD). The present study aimed to identify associations between neuropsychiatric symptoms as measured by the Neuropsychiatric Inventory-Questionnaire (NPI-Q) and cognitive and functional performance. Participants were 256 AD patients enrolled in the Alzheimer's Disease and Memory Disorders Center at Baylor College of Medicine. An exploratory factor analysis of the NPI-Q indicated a 2-factor structure consisting of Negative/Oppositional and Anxiety/Restlessness factors. Regression analyses revealed significant associations between greater total severity of neuropsychiatric symptoms and poorer performance on basic and Instrumental Activities of Daily Living. Greater severity of Anxiety/Restlessness symptoms was associated with poor performance on measures of visuospatial functioning and basic and instrumental activities of daily living. The Negative/Oppositional factor was not related to cognition or functioning. In summary, neuropsychiatric symptoms (particularly Anxiety/Restlessness symptoms) were related to cognition and everyday functioning. Proper assessment and treatment of these symptoms is essential for improving cognition and functioning in AD patients.

  8. Baccalaureate nursing students' perspectives of peer tutoring in simulation laboratory, a Q methodology study.

    PubMed

    Li, Ting; Petrini, Marcia A; Stone, Teresa E

    2018-02-01

    The study aim was to identify the perceived perspectives of baccalaureate nursing students toward the peer tutoring in the simulation laboratory. Insight into the nursing students' experiences and baseline data related to their perception of peer tutoring will assist to improve nursing education. Q methodology was applied to explore the students' perspectives of peer tutoring in the simulation laboratory. A convenience P-sample of 40 baccalaureate nursing students was used. Fifty-eight selected Q statements from each participant were classified into the shape of a normal distribution using an 11-point bipolar scale form with a range from -5 to +5. PQ Method software analyzed the collected data. Three discrete factors emerged: Factor I ("Facilitate or empower" knowledge acquisition), Factor II ("Safety Net" Support environment), and Factor III ("Mentoring" learn how to learn). The findings of this study support and indicate that peer tutoring is an effective supplementary strategy to promote baccalaureate students' knowledge acquisition, establishing a supportive safety net and facilitating their abilities to learn in the simulation laboratory. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. EXERCISES THAT FACILITATE OPTIMAL HAMSTRING AND QUADRICEPS CO-ACTIVATION TO HELP DECREASE ACL INJURY RISK IN HEALTHY FEMALES: A SYSTEMATIC REVIEW OF THE LITERATURE.

    PubMed Central

    Dedinsky, Rachel; Baker, Lindsey; Imbus, Samuel; Bowman, Melissa

    2017-01-01

    Background Anterior cruciate ligament (ACL) injury is common among females due to many anatomic, hormonal, and neuromuscular risk factors. One modifiable risk factor that places females at increased risk of ACL injury is a poor hamstrings: quadriceps (H:Q) co-activation ratio, which should be 0.6 or greater in order to decrease the stress placed on the ACL. Exercises that produce more quadriceps dominant muscle activation can add to the tension placed upon the ACL, potentially increasing the risk of ACL injury. Hypothesis/Purpose The purpose of this systematic review was to compare quadriceps and hamstring muscle activation during common closed kinetic chain therapeutic exercises in healthy female knees to determine what exercises are able to produce adequate H:Q co-activation ratios. Study Design Systematic Review Methods Multiple online databases were systematically searched and screened for inclusion. Eight articles were identified for inclusion. Data on mean electromyography (EMG) activation of both quadriceps and hamstring muscles, % maximal voluntary isometric contraction (MVIC), and H:Q co-activation ratios were extracted from the studies. Quality assessment was performed on all included studies. Results Exercises analyzed in the studies included variations of the double leg squat, variations of the single leg squat, lateral step-up, Fitter, Stairmaster® (Core Health and Fitness, Vancouver, WA), and slide board. All exercises, except the squat machine with posterior support at the level of the scapula and feet placed 50 cm in front of the hips, produced higher quadriceps muscle activation compared to hamstring muscle activation. Conclusion Overall, two leg squats demonstrate poor H:Q co-activation ratios. Single leg exercises, when performed between 30 and 90 degrees of knee flexion, produce adequate H:Q ratios, thereby potentially reducing the risk of tensile stress on the ACL and ACL injury. Level of Evidence 2a- Systematic Review of Cohort Studies PMID:28217412

  10. Beneficial effects of aged garlic extract and coenzyme Q10 on vascular elasticity and endothelial function: The FAITH randomized clinical trial

    PubMed Central

    Larijani, Vahid Nabavi; Ahmadi, Naser; Zeb, Irfan; Khan, Faraz; Flores, Ferdinand; Budoff, Matthew

    2014-01-01

    Objective Aged garlic extract (AGE) is associated with a significant decrease in atherosclerotic plaque progression and endothelial function improvement. Similarly, coenzyme Q10 (CoQ10) has significant beneficial effects on endothelial function. A stressful lifestyle is a well-known risk factor for the presence and progression of atherosclerosis. This study investigated the effect of AGE plus CoQ10 on vascular elasticity measured by pulse-wave velocity (PWV) and endothelial function measured by digital thermal monitoring (DTM) in firefighters. Methods Sixty-five Los-Angeles County firefighters who met the eligibility criteria were enrolled in this placebo-controlled, double-blinded randomized trial. The firefighters were randomized to four tablets of AGE (300 mg/tablet) plus CoQ10 (30 mg/tablet) or placebo. The participants underwent quarterly visits and 1-year follow-up. PWV and DTM were measured at baseline and at the 1-year follow-up. Results There were no significant differences in age, cardiovascular risk factors, PWV, and DTM between the AGE/CoQ10 and placebo groups at baseline (P > 0.5). At 1-y, PWV and DTM significantly improved in the AGE/CoQ10 compared with the placebo group (P < 0.05). After an adjustment for cardiovascular risk factors and statin therapy, the mean decrease in vascular stiffness (PWV) was 1.21 m/s in the AGE/CoQ10 compared with the placebo group (P = 0.005). Similarly, the mean increase in the area under the temperature curve, the DTM index of endothelial function, was 31.3 in the AGE/CoQ10 compared with the placebo group (P = 0.01). Conclusion The combination of AGE and CoQ10 was independently associated with significant beneficial effects on vascular elasticity and endothelial function in firefighters with high occupational stress, highlighting the important role of AGE and CoQ10 in atherosclerotic prevention of such individuals. PMID:22858191

  11. Examining intentions to use CoQ10 amongst breast cancer patients.

    PubMed

    Hill, Gina Jarman; Shriver, Brent J; Arnett, Dennis B

    2006-01-01

    To determine factors that influence breast cancer patients' intentions to supplement with CoQ10. A survey based upon the expanded rational expectations intentions model was completed by breast cancer outpatients (N=160). A significantly positive relationship existed between referent other (the influence specific people have in terms of an individual's behavior) and subjective norm (subject's perception of how people view a behavior). Beliefs, referent other, attitude, and subjective norm did have a significant effect on intention to use CoQ10. Health practitioners may address supplementation with breast cancer patients with a better understanding of what factors impact supplement use.

  12. First measurement of proton's charge form factor at very low Q2 with initial state radiation

    NASA Astrophysics Data System (ADS)

    Mihovilovič, M.; Weber, A. B.; Achenbach, P.; Beranek, T.; Beričič, J.; Bernauer, J. C.; Böhm, R.; Bosnar, D.; Cardinali, M.; Correa, L.; Debenjak, L.; Denig, A.; Distler, M. O.; Esser, A.; Ferretti Bondy, M. I.; Fonvieille, H.; Friedrich, J. M.; Friščić, I.; Griffioen, K.; Hoek, M.; Kegel, S.; Kohl, Y.; Merkel, H.; Middleton, D. G.; Müller, U.; Nungesser, L.; Pochodzalla, J.; Rohrbeck, M.; Sánchez Majos, S.; Schlimme, B. S.; Schoth, M.; Schulz, F.; Sfienti, C.; Širca, S.; Štajner, S.; Thiel, M.; Tyukin, A.; Vanderhaeghen, M.; Weinriefer, M.

    2017-08-01

    We report on a new experimental method based on initial-state radiation (ISR) in e-p scattering, which exploits the radiative tail of the elastic peak to study the properties of electromagnetic processes and to extract the proton charge form factor (GEp) at extremely small Q2. The ISR technique was implemented in an experiment at the three-spectrometer facility of the Mainz Microtron (MAMI). This led to a precise validation of radiative corrections far away from elastic line and provided first measurements of GEp for 0.001 ≤Q2 ≤ 0.004(GeV / c)2.

  13. Drop of coherence of the lower kilo-Hz QPO in neutron stars: Is there a link with the innermost stable circular orbit?

    NASA Astrophysics Data System (ADS)

    Barret, D.; Olive, J.-F.; Miller, M. Coleman

    2005-11-01

    Using all available archival data from the Rossi X-ray Timing Explorer (RXTE), we follow the frequency of the kilo-Hz QPOs in three low luminosity neutron star low mass X-ray binaries; namely 4U 1636-536, 4U 1608-522, and 4U 1735-44. Following earlier work by Barret et al. (2005a,b), we focus our analysis on the lower kilo-Hz QPO, for which we study the dependency of its quality factor (Q=\

  14. Complementary metal-oxide semiconductor compatible source of single photons at near-visible wavelengths

    NASA Astrophysics Data System (ADS)

    Cernansky, Robert; Martini, Francesco; Politi, Alberto

    2018-02-01

    We demonstrate on chip generation of correlated pairs of photons in the near-visible spectrum using a CMOS compatible PECVD Silicon Nitride photonic device. Photons are generated via spontaneous four wave mixing enhanced by a ring resonator with high quality Q-factor of 320,000 resulting in a generation rate of 950,000 $\\frac{pairs}{mW}$. The high brightness of this source offers the opportunity to expand photonic quantum technologies over a broad wavelength range and provides a path to develop fully integrated quantum chips working at room temperature.

  15. Experimental studies on the acoustic properties of mastoid cavities.

    PubMed

    Tolley, N S; Ison, K; Mirza, A

    1992-07-01

    This study investigated the effects of open-mastoid surgery upon ear canal resonance. In particular an attempt was made to alter resonant properties by obliterating each cavity with silastic foam. The results from this study showed that open-mastoid surgery significantly decreased resonant frequency without producing an effect upon either the peak amplitude or the quality of the resonant peak as defined by the Q-factor. Restoring the natural resonance properties of an operated ear, if indicated, is likely to be a difficult objective to achieve in surgical terms.

  16. Physics of near-wavelength high contrast gratings.

    PubMed

    Karagodsky, Vadim; Chang-Hasnain, Connie J

    2012-05-07

    We present a simple theory explaining the extraordinary features of high-contrast optical gratings in the near-wavelength regime, particularly the very broadband high reflectivity (>99%) and the ultra-high quality factor resonances (Q>10(7)). We present, for the first time, an intuitive explanation for both features using a simple phase selection rule, and reveal the anti-crossing and crossing effects between the grating modes. Our analytical results agree well with simulations and the experimental data obtained from vertical cavity surface emitting lasers incorporating a high contrast grating as top reflector.

  17. Progress in performance enhancement methods for capacitive silicon resonators

    NASA Astrophysics Data System (ADS)

    Van Toan, Nguyen; Ono, Takahito

    2017-11-01

    In this paper, we review the progress in recent studies on the performance enhancement methods for capacitive silicon resonators. We provide information on various fabrication technologies and design considerations that can be employed to improve the performance of capacitive silicon resonators, including low motional resistance, small insertion loss, and high quality factor (Q). This paper contains an overview of device structures and working principles, fabrication technologies consisting of hermetic packaging, deep reactive-ion etching and neutral beam etching, and design considerations including mechanically coupled, movable electrode structures and piezoresistive heat engines.

  18. Ultra-high-Q three-dimensional photonic crystal nano-resonators.

    PubMed

    Tang, Lingling; Yoshie, Tomoyuki

    2007-12-10

    Two nano-resonator modes are designed in a woodpile three-dimensional photonic crystal by the modulation of unit cell size along a low-loss optical waveguide. One is a dipole mode with 2.88 cubic half-wavelengths mode volume. The other is a quadrupole mode with 8.3 cubic half-wavelengths mode volume. Light is three-dimensionally confined by a complete photonic band gap so that, in the analyzed range, the quality factor exponentially increases as the increase in the number of unit cells used for confinement of light.

  19. Characterization of Mid-Infrared Single Mode Fibers as Modal Filters

    NASA Technical Reports Server (NTRS)

    Ksendzov, A.; Lay, O.; Martin, S.; Sanghera, J. S.; Busse, L. E.; Kim, W. H.; Pureza, P. C.; Nguyen, V. Q.; Aggarwal, I. D.

    2007-01-01

    We present a technique for measuring the modal filtering ability of single mode fibers. The ideal modal filter rejects all input field components that have no overlap with the fundamental mode of the filter and does not attenuate the fundamental mode. We define the quality of a nonideal modal filter Q(sub f) as the ratio of transmittance for the fundamental mode to the transmittance for an input field that has no overlap with the fundamental mode. We demonstrate the technique on a 20 cm long mid-infrared fiber that was produced by the U.S. Naval Research Laboratory. The filter quality Q(sub f) for this fiber at 10.5 micron wavelength is 1000 +/- 300. The absorption and scattering losses in the fundamental mode are approximately 8 dB/m. The total transmittance for the fundamental mode, including Fresnel reflections, is 0.428 +/- 0.002. The application of interest is the search for extrasolar Earthlike planets using nulling interferometry. It requires high rejection ratios to suppress the light of a bright star, so that the faint planet becomes visible. The use of modal filters increases the rejection ratio (or, equivalently, relaxes requirements on the wavefront quality) by reducing the sensitivity to small wavefront errors. We show theoretically that, exclusive of coupling losses, the use of a modal filter leads to the improvement of the rejection ratio in a two-beam interferometer by a factor of Q(sub f).

  20. Quantum Discord in a Spin System with Symmetry Breaking

    NASA Astrophysics Data System (ADS)

    Tomasello, Bruno; Rossini, Davide; Hamma, Alioscia; Amico, Luigi

    2013-06-01

    We analyze the quantum discord Q throughout the low temperature phase diagram of the quantum XY model in transverse field. We first focus on the T = 0 order-disorder quantum phase transition QPT both in the symmetric ground state and in the symmetry broken one. Beside it, we highlight how Q displays clear anomalies also at a noncritical value of the control parameter inside the ordered phase, where the ground state is completely factorized. We evidence how the phenomenon is in fact of collective nature and displays universal features. We also study Q at finite temperature. We show that, close to the QPT, Q exhibits quantum-classical crossover of the system with universal scaling behavior. We evidence a nontrivial pattern of thermal correlations resulting from the factorization phenomenon.

Top