Sample records for quality factor q0

  1. [Uncertainty of cross calibration-applied beam quality conversion factor for the Japan Society of Medical Physics 12].

    PubMed

    Kinoshita, Naoki; Kita, Akinobu; Takemura, Akihiro; Nishimoto, Yasuhiro; Adachi, Toshiki

    2014-09-01

    The uncertainty of the beam quality conversion factor (k(Q,Q0)) of standard dosimetry of absorbed dose to water in external beam radiotherapy 12 (JSMP12) is determined by combining the uncertainty of each beam quality conversion factor calculated for each type of ionization chamber. However, there is no guarantee that ionization chambers of the same type have the same structure and thickness, so there may be individual variations. We evaluated the uncertainty of k(Q,Q0) for JSMP12 using an ionization chamber dosimeter and linear accelerator without a specific device or technique in consideration of the individual variation of ionization chambers and in clinical radiation field. The cross calibration formula was modified and the beam quality conversion factor for the experimental values [(k(Q,Q0))field] determined using the modified formula. It's uncertainty was calculated to be 1.9%. The differences between (k(Q,Q0))field of experimental values and k(Q,Q0) for Japan Society of Medical Physics 12 (JSMP12) were 0.73% and 0.88% for 6- and 10-MV photon beams, respectively, remaining within ± 1.9%. This showed k(Q,Q0) for JSMP12 to be consistent with (k(Q,Q0))field of experimental values within the estimated uncertainty range. Although inter-individual differences may be generated, even when the same type of ionized chamber is used, k(Q,Q0) for JSMP12 appears to be consistent within the estimated uncertainty range of (k(Q,Q0)field.

  2. Frequency dependent Lg attenuation in south-central Alaska

    USGS Publications Warehouse

    McNamara, D.E.

    2000-01-01

    The characteristics of seismic energy attenuation are determined using high frequency Lg waves from 27 crustal earthquakes, in south-central Alaska. Lg time-domain amplitudes are measured in five pass-bands and inverted to determine a frequency-dependent quality factor, Q(f), model for south-central Alaska. The inversion in this study yields the frequency-dependent quality factor, in the form of a power law: Q(f) = Q0fη = 220(±30) f0.66(±0.09) (0.75≤f≤12Hz). The results from this study are remarkably consistent with frequency dependent quality factor estimates, using local S-wave coda, in south-central Alaska. The consistency between S-coda Q(f) and Lg Q(f) enables constraints to be placed on the mechanism of crustal attenuation in south-central Alaska. For the range of frequencies considered in this study both scattering and intrinsic attenuation mechanisms likely play an equal role.

  3. SU-F-BRD-15: Quality Correction Factors in Scanned Or Broad Proton Therapy Beams Are Indistinguishable

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sorriaux, J; Lee, J; ICTEAM Institute, Universite catholique de Louvain, Louvain-la-Neuve

    2015-06-15

    Purpose: The IAEA TRS-398 code of practice details the reference conditions for reference dosimetry of proton beams using ionization chambers and the required beam quality correction factors (kQ). Pencil beam scanning (PBS) requires multiple spots to reproduce the reference conditions. The objective is to demonstrate, using Monte Carlo (MC) calculations, that kQ factors for broad beams can be used for scanned beams under the same reference conditions with no significant additional uncertainty. We consider hereafter the general Alfonso formalism (Alfonso et al, 2008) for non-standard beam. Methods: To approach the reference conditions and the associated dose distributions, PBS must combinemore » many pencil beams with range modulation and shaping techniques different than those used in passive systems (broad beams). This might lead to a different energy spectrum at the measurement point. In order to evaluate the impact of these differences on kQ factors, ion chamber responses are computed with MC (Geant4 9.6) in a dedicated scanned pencil beam (Q-pcsr) producing a 10×10cm2 composite field with a flat dose distribution from 10 to 16 cm depth. Ion chamber responses are also computed by MC in a broad beam with quality Q-ds (double scattering). The dose distribution of Q -pcsr matches the dose distribution of Q-ds. k-(Q-pcsr,Q-ds) is computed for a 2×2×0.2cm{sup 3} idealized air cavity and a realistic plane-parallel ion chamber (IC). Results: Under reference conditions, quality correction factors for a scanned composite field versus a broad beam are the same for air cavity dose response, k-(Q-pcsr,Q-ds) =1.001±0.001 and for a Roos IC, k-(Q-pcsr,Q-ds) =0.999±0.005. Conclusion: Quality correction factors for ion chamber response in scanned and broad proton therapy beams are identical under reference conditions within the calculation uncertainties. The results indicate that quality correction factors published in IAEA TRS-398 can be used for scanned beams in the SOBP of a high-energy proton beam. Jefferson Sorriaux is financed by the Walloon Region under the convention 1217662. Jefferson Sorriaux is sponsored by a public-private partnership IBA - Walloon Region.« less

  4. Microcrystalline diamond cylindrical resonators with quality-factor up to 0.5 million

    NASA Astrophysics Data System (ADS)

    Saito, Daisuke; Yang, Chen; Heidari, Amir; Najar, Hadi; Lin, Liwei; Horsley, David A.

    2016-02-01

    We demonstrate high quality-factor 1.5 mm diameter batch-fabricated microcrystalline diamond cylindrical resonators (CR) with quality-factors limited by thermoelastic damping (TED) and surface loss. Resonators were fabricated 2.6 and 5.3 μm thick in-situ boron-doped microcrystalline diamond films deposited using hot filament chemical vapor deposition. The quality-factor (Q) of as-fabricated CR's was found to increase with the resonator diameter and diamond thickness. Annealing the CRs at 700 °C in a nitrogen atmosphere led to a three-fold increase in Q, a result we attribute to thinning of the diamond layer via reaction with residual O2 in the annealing furnace. Post-anneal Q exceeding 0.5 million (528 000) was measured at the 19 kHz elliptical wineglass modes, producing a ring-down time of 8.9 s. A model for Q versus diamond thickness and resonance frequency is developed including the effects of TED and surface loss. Measured quality factors are shown to agree with the predictions of this model.

  5. Systematic uncertainties in RF-based measurement of superconducting cavity quality factors

    DOE PAGES

    Holzbauer, J. P.; Pischalnikov, Yu.; Sergatskov, D. A.; ...

    2016-05-10

    Q 0 determinations based on RF power measurements are subject to at least three potentially large systematic effects that have not been previously appreciated. Here, instrumental factors that can systematically bias RF based measurements of Q 0 are quantified and steps that can be taken to improve the determination of Q 0 are discussed.

  6. Microcrystalline diamond cylindrical resonators with quality-factor up to 0.5 million

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saito, Daisuke; Yang, Chen; Lin, Liwei

    2016-02-01

    We demonstrate high quality-factor 1.5 mm diameter batch-fabricated microcrystalline diamond cylindrical resonators (CR) with quality-factors limited by thermoelastic damping (TED) and surface loss. Resonators were fabricated 2.6 and 5.3 μm thick in-situ boron-doped microcrystalline diamond films deposited using hot filament chemical vapor deposition. The quality-factor (Q) of as-fabricated CR's was found to increase with the resonator diameter and diamond thickness. Annealing the CRs at 700 °C in a nitrogen atmosphere led to a three-fold increase in Q, a result we attribute to thinning of the diamond layer via reaction with residual O{sub 2} in the annealing furnace. Post-anneal Q exceeding 0.5 million (528 000)more » was measured at the 19 kHz elliptical wineglass modes, producing a ring-down time of 8.9 s. A model for Q versus diamond thickness and resonance frequency is developed including the effects of TED and surface loss. Measured quality factors are shown to agree with the predictions of this model.« less

  7. Evaluating signal and noise spectral density of a qPlus sensor with an active feedback control

    NASA Astrophysics Data System (ADS)

    Lee, Manhee; An, Sangmin; Jhe, Wonho

    2018-05-01

    Q-control technique enables to actively change the quality factor of the probe oscillation in dynamic atomic force microscopy. The Q-control is realized by adding a self-feedback loop into the original actuation-detection system, in which a damping force with controllable damping coefficient in magnitude and sign is applied to the oscillating probe. While the applied force alters the total damping interaction and thus the overall `signal' of the probe motion, the added feedback system changes the `noise' of the motion as well. Here, we systematically investigate the signal, the noise, and the signal-to-noise ratio of the qPlus sensor under the active Q-control. We quantify the noise of the qPlus motion by measuring the noise spectral density, which is reproduced by a harmonic oscillator model including the thermal and the measurement noises. We show that the noise signal increases with the quality factor controlled, scaling as the square root of the quality factor. Because the overall signal is linearly proportional to the quality factor, the signal-to-noise ratio scales as the square root of the quality factor. The Q-controlled qPlus with a highly enhanced Q, up to 10,000 in air, leads to the minimum detectable force gradient of 0.001 N/m, which would enhance the capability of the qPlus sensor for atomic force microscopy and spectroscopy.

  8. SU-E-T-408: Determination of KQ,Q0-Factors From Water and Graphite Calorimetry in a 60 MeV Proton Beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rossomme, S; Renaud, J; Sarfehnia, A

    2014-06-01

    Purpose: To reduce the uncertainty of the beam quality correction factor k Q,Q0, for scattered proton beams (SPB). This factor is used in dosimetry protocols, to determine absorbed dose-to-water with ionization chambers. For the Roos plane parallel chambers (RPPICs), the IAEA TRS-398 protocol estimates k Q,Q0-factor to be 1.004(for a beam quality Rres=2 g.cm{sup 2}), with an uncertainty of 2.1%. Methods: A graphite calorimeter (GCal), a water calorimeter (WCal) and RPPICs were exposed, in a single experiment, to a 60 MeV non-modulated SPB. RPPICs were calibrated in terms of absorbed dose-to-water in a 20 MeV electron beam. The calibration coefficientmore » is traceable to NPL's absorbed dose standards. Chamber measurements were corrected for environmental conditions, recombination and polarity. The WCal corrections include heat loss, heat defect and vessel perturbation. The GCal corrections include heat loss and absorbed dose conversion. Except for heat loss correction and its uncertainty in the WCal system, all major corrections were included in the analysis. Other minor corrections, such as beam profile non-uniformity, are still to be evaluated. Experimental k Q,Q0-factors were derived by comparing the results obtained with both calorimeters and ionometry. Results: The absorbed dose-to-water from both calorimeters was found to be within 1.3% with an uncertainty of 1.2%. k Q,Q0-factor for a RPPIC was found to be 0.998 and 1.011, with a standard uncertainty of 1.4% and 0.9% when the dose is based on the GCal and the WCal, respectively. Conclusion: Results suggest the possibility to determine k Q,Q0-values for PPICs in SPB with a lower uncertainty than specified in the TRS-398 thereby helping to reduce uncertainty on absorbed dose-to-water. The agreement between calorimeters confirms the possibility to use GCal or WCal as primary standard in SPB. Because of the dose conversion, the use of GCal may lead to slightly higher uncertainty, but is, at present, considerably easier to operate.« less

  9. Quench-induced degradation of the quality factor in superconducting resonators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Checchin, M.; Martinello, M.; Romanenko, A.

    Quench of superconducting radio-frequency cavities frequently leads to the lowered quality factor Q 0, which had been attributed to the additional trapped magnetic flux. Here we demonstrate that the origin of this magnetic flux is purely extrinsic to the cavity by showing no extra dissipation (unchanged Q 0) after quenching in zero magnetic field, which allows us to rule out intrinsic mechanisms of flux trapping such as generation of thermal currents or trapping of the rf field. We also show the clear relation of dissipation introduced by quenching to the orientation of the applied magnetic field and the possibility tomore » fully recover the quality factor by requenching in the compensated field. We discover that for larger values of the ambient field, the Q-factor degradation may become irreversible by this technique, likely due to the outward flux migration beyond the normal zone opening during quench. Lastly, our findings are of special practical importance for accelerators based on low- and medium-beta accelerating structures residing close to focusing magnets, as well as for all high-Q cavity-based accelerators.« less

  10. Quench-induced degradation of the quality factor in superconducting resonators

    DOE PAGES

    Checchin, M.; Martinello, M.; Romanenko, A.; ...

    2016-04-28

    Quench of superconducting radio-frequency cavities frequently leads to the lowered quality factor Q 0, which had been attributed to the additional trapped magnetic flux. Here we demonstrate that the origin of this magnetic flux is purely extrinsic to the cavity by showing no extra dissipation (unchanged Q 0) after quenching in zero magnetic field, which allows us to rule out intrinsic mechanisms of flux trapping such as generation of thermal currents or trapping of the rf field. We also show the clear relation of dissipation introduced by quenching to the orientation of the applied magnetic field and the possibility tomore » fully recover the quality factor by requenching in the compensated field. We discover that for larger values of the ambient field, the Q-factor degradation may become irreversible by this technique, likely due to the outward flux migration beyond the normal zone opening during quench. Lastly, our findings are of special practical importance for accelerators based on low- and medium-beta accelerating structures residing close to focusing magnets, as well as for all high-Q cavity-based accelerators.« less

  11. Quench-Induced Degradation of the Quality Factor in Superconducting Resonators

    NASA Astrophysics Data System (ADS)

    Checchin, M.; Martinello, M.; Romanenko, A.; Grassellino, A.; Sergatskov, D. A.; Posen, S.; Melnychuk, O.; Zasadzinski, J. F.

    2016-04-01

    Quench of superconducting radio-frequency cavities frequently leads to the lowered quality factor Q0 , which had been attributed to the additional trapped magnetic flux. Here we demonstrate that the origin of this magnetic flux is purely extrinsic to the cavity by showing no extra dissipation (unchanged Q0) after quenching in zero magnetic field, which allows us to rule out intrinsic mechanisms of flux trapping such as generation of thermal currents or trapping of the rf field. We also show the clear relation of dissipation introduced by quenching to the orientation of the applied magnetic field and the possibility to fully recover the quality factor by requenching in the compensated field. We discover that for larger values of the ambient field, the Q -factor degradation may become irreversible by this technique, likely due to the outward flux migration beyond the normal zone opening during quench. Our findings are of special practical importance for accelerators based on low- and medium-β accelerating structures residing close to focusing magnets, as well as for all high-Q cavity-based accelerators.

  12. A brachytherapy photon radiation quality index Q(BT) for probe-type dosimetry.

    PubMed

    Quast, Ulrich; Kaulich, Theodor W; Álvarez-Romero, José T; Carlsson Tedgren, Sa; Enger, Shirin A; Medich, David C; Mourtada, Firas; Perez-Calatayud, Jose; Rivard, Mark J; Zakaria, G Abu

    2016-06-01

    In photon brachytherapy (BT), experimental dosimetry is needed to verify treatment plans if planning algorithms neglect varying attenuation, absorption or scattering conditions. The detector's response is energy dependent, including the detector material to water dose ratio and the intrinsic mechanisms. The local mean photon energy E¯(r) must be known or another equivalent energy quality parameter used. We propose the brachytherapy photon radiation quality indexQ(BT)(E¯), to characterize the photon radiation quality in view of measurements of distributions of the absorbed dose to water, Dw, around BT sources. While the external photon beam radiotherapy (EBRT) radiation quality index Q(EBRT)(E¯)=TPR10(20)(E¯) is not applicable to BT, the authors have applied a novel energy dependent parameter, called brachytherapy photon radiation quality index, defined as Q(BT)(E¯)=Dprim(r=2cm,θ0=90°)/Dprim(r0=1cm,θ0=90°), utilizing precise primary absorbed dose data, Dprim, from source reference databases, without additional MC-calculations. For BT photon sources used clinically, Q(BT)(E¯) enables to determine the effective mean linear attenuation coefficient μ¯(E) and thus the effective energy of the primary photons Eprim(eff)(r0,θ0) at the TG-43 reference position Pref(r0=1cm,θ0=90°), being close to the mean total photon energy E¯tot(r0,θ0). If one has calibrated detectors, published E¯tot(r) and the BT radiation quality correction factor [Formula: see text] for different BT radiation qualities Q and Q0, the detector's response can be determined and Dw(r,θ) measured in the vicinity of BT photon sources. This novel brachytherapy photon radiation quality indexQ(BT) characterizes sufficiently accurate and precise the primary photon's penetration probability and scattering potential. Copyright © 2016. Published by Elsevier Ltd.

  13. Internal friction Q factor measurements in lunar rocks

    NASA Technical Reports Server (NTRS)

    Tittmann, B. R.

    1977-01-01

    Investigations to aid in the interpretation of seismic data obtained below the lunar surface are reported. Fine grained basalt with about 1.0% open core porosity was encapsulated under hard vacuum and measured. A Q value just under 2,000 at 0.5 kbar was achieved for a terrestrial analog of lunar basalt. In contrast to the modulus which increases by as much as 10%, the quality factor Q shows little or no change with pressure (a well outgassed sample maintains a high Q, whereas one exposed to laboratory atmosphere maintains a low Q). This result suggests that the absence of volatiles plays an important role in determining the q factor even at a depth of 10 km below the lunar surface.

  14. New determinations of Q quality factors and eigenfrequencies for the whole set of singlets of the Earth's normal modes 0S 0, 0S 2, 0S 3 and 2S 1 using superconducting gravimeter data from the GGP network

    NASA Astrophysics Data System (ADS)

    Roult, Geneviève; Rosat, Séverine; Clévédé, Eric; Millot-Langet, Raphaële; Hinderer, Jacques

    2006-01-01

    We present new modal Q measurements of the 0S 0 and 0S 2 modes, and first modal frequencies and Q measurements of 2S 1 and 0S 3 modes. The high quality of the GGP (Global Geodynamics Project) superconducting gravimeters (SGs) contributes to the clear observation of seismic normal modes at frequencies lower than 1 mHz and offers a good opportunity for studying the behaviour of these modes. The interest of scientists in the gravest normal modes is due to the fact that they do contribute to a better knowledge of the density profile in the Earth, helping to constrain Earth's models. These modes have been clearly identified after some large recent events recorded with superconducting gravimeters, particularly well-suited for low-frequency investigations. The Ms = 8.1 (Mw = 8.4) Peruvian earthquake of June 2001 and the Ms = 9.0 (Mw = 9.3) Sumatra-Andaman earthquake of December 2004 provide us with individual spectra which exhibit a clear splitting of the spheroidal modes 0S 2, 0S 3 and 2S 1, and a clear identification of each of the individual singlets, with a resolution never obtained from broad-band seismometers records. The Q quality factors have been determined from the apparent decrease of the amplitude of each singlet with time, according to a well-suited technique [Roult, G., Clévédé, E., 2000. New refinements in attenuation measurements from free-oscillation and surface-wave observations. Phys. Earth Planet. Inter. 121, 1-37]. The results are compared to the theoretical frequencies and Q quality factors computed for the PREM and 1066A models, taking into account both rotation and ellipticity effects of the Earth. The two observed datasets (frequencies and Q quality factors) exhibit a splitting on the observed values different from the predicted one. That seems to point out that some parameters as density or attenuation values used in the theoretical models do not explain the observations. A new dataset of frequencies and Q quality factors of the whole set of singlets of the gravest spheroidal modes is thus under construction. That dataset includes the five individual singlets of the 0S 2 mode clearly identified on the SG records, the three singlets of the 2S 1 mode recently observed for the first time by [Rosat, S., Hinderer, J., Rivera, L., 2003b. First observation of 2S 1 and study of the splitting of the football mode 0S 2 after the June 2001 Peru earthquake of magnitude 8.4. Geophys. Res. Lett. 30, 21211, doi:10-1029/2003L018304], the 0S 0 radial mode, and the seven individual singlets of the 0S 3 mode.

  15. Direct determination of k Q factors for cylindrical and plane-parallel ionization chambers in high-energy electron beams from 6 MeV to 20 MeV.

    PubMed

    Krauss, A; Kapsch, R-P

    2018-02-06

    For the ionometric determination of the absorbed dose to water, D w , in high-energy electron beams from a clinical accelerator, beam quality dependent correction factors, k Q , are required. By using a water calorimeter, these factors can be determined experimentally and potentially with lower standard uncertainties than those of the calculated k Q factors, which are tabulated in various dosimetry protocols. However, one of the challenges of water calorimetry in electron beams is the small measurement depths in water, together with the steep dose gradients present especially at lower energies. In this investigation, water calorimetry was implemented in electron beams to determine k Q factors for different types of cylindrical and plane-parallel ionization chambers (NE2561, NE2571, FC65-G, TM34001) in 10 cm  ×  10 cm electron beams from 6 MeV to 20 MeV (corresponding beam quality index R 50 ranging from 1.9 cm to 7.5 cm). The measurements were carried out using the linear accelerator facility of the Physikalisch-Technische Bundesanstalt. Relative standard uncertainties for the k Q factors between 0.50% for the 20 MeV beam and 0.75% for the 6 MeV beam were achieved. For electron energies above 8 MeV, general agreement was found between the relative electron energy dependencies of the k Q factors measured and those derived from the AAPM TG-51 protocol and recent Monte Carlo-based studies, as well as those from other experimental investigations. However, towards lower energies, discrepancies of up to 2.0% occurred for the k Q factors of the TM34001 and the NE2571 chamber.

  16. Direct determination of k Q factors for cylindrical and plane-parallel ionization chambers in high-energy electron beams from 6 MeV to 20 MeV

    NASA Astrophysics Data System (ADS)

    Krauss, A.; Kapsch, R.-P.

    2018-02-01

    For the ionometric determination of the absorbed dose to water, D w, in high-energy electron beams from a clinical accelerator, beam quality dependent correction factors, k Q, are required. By using a water calorimeter, these factors can be determined experimentally and potentially with lower standard uncertainties than those of the calculated k Q factors, which are tabulated in various dosimetry protocols. However, one of the challenges of water calorimetry in electron beams is the small measurement depths in water, together with the steep dose gradients present especially at lower energies. In this investigation, water calorimetry was implemented in electron beams to determine k Q factors for different types of cylindrical and plane-parallel ionization chambers (NE2561, NE2571, FC65-G, TM34001) in 10 cm  ×  10 cm electron beams from 6 MeV to 20 MeV (corresponding beam quality index R 50 ranging from 1.9 cm to 7.5 cm). The measurements were carried out using the linear accelerator facility of the Physikalisch-Technische Bundesanstalt. Relative standard uncertainties for the k Q factors between 0.50% for the 20 MeV beam and 0.75% for the 6 MeV beam were achieved. For electron energies above 8 MeV, general agreement was found between the relative electron energy dependencies of the k Q factors measured and those derived from the AAPM TG-51 protocol and recent Monte Carlo-based studies, as well as those from other experimental investigations. However, towards lower energies, discrepancies of up to 2.0% occurred for the k Q factors of the TM34001 and the NE2571 chamber.

  17. Relationship between daily isoflavone intake and sleep in Japanese adults: a cross-sectional study.

    PubMed

    Cui, Yufei; Niu, Kaijun; Huang, Cong; Momma, Haruki; Guan, Lei; Kobayashi, Yoritoshi; Guo, Hui; Chujo, Masahiko; Otomo, Atsushi; Nagatomi, Ryoichi

    2015-12-29

    Isoflavones comprise a class of phytoestrogens that resemble human estrogen in chemical structure, and have weak estrogenic effects. Because estrogen modulates sleep duration and quality, we hypothesized that isoflavones would have a beneficial effect on sleep status in a way similar to estrogen. We conducted a cross-sectional study to investigate the relationship between daily isoflavone intake and sleep status in Japanese subjects. Our study included 1076 Japanese adults aged 20-78 years. Daily isoflavone intake was assessed using a brief self-administered diet history questionnaire, and sleep was evaluated using a self-reported questionnaire. The prevalence of regular sleep duration (7-8 h/day) and sufficient sleep quality were 13.3% and 56.2%, respectively. After adjusting for potential confounding factors, the odds ratios (95% CIs) for optimal sleep duration (7-8 h) when higher isoflavone intakes (Q2-Q4) were compared with low isoflavone intake (Q1) were Q2: 0.94 (0.53-1.56); Q3: 1.28 (0.73-2.24); and Q4: 1.84 (1.06-3.18) (p for trend = 0.013). In the final adjusted model, sufficient sleep quality across categories of isoflavone intake was Q1: 1.00 (reference); Q2: 1.30 (0.91-1.84); Q3: 1.48 (1.03-2.12); and Q4: 1.78 (1.22-2.60); (p for trend = 0.002). Higher daily isoflavone intake was positively associated with optimal sleep duration and quality in a Japanese population. This finding suggests that daily isoflavone intake may have a potentially beneficial effect on sleep status.

  18. Healthful dietary patterns and long-term weight change among women with a history of gestational diabetes mellitus.

    PubMed

    Tobias, D K; Zhang, C; Chavarro, J; Olsen, S; Bao, W; Bjerregaard, A A; Fung, T T; Manson, J E; Hu, F B

    2016-11-01

    Diet represents a key strategy for the prevention of obesity and type 2 diabetes among women with a history of gestational diabetes mellitus (GDM), although effective dietary patterns to prevent weight gain in the long term are largely unknown. We sought to evaluate whether improvement in overall diet quality is associated with less long-term weight gain among high-risk women with prior GDM. Women with a history of GDM (N=3397) were followed from 1991 to 2011, or until diagnosis of type 2 diabetes or other chronic disease. Usual diet was assessed via food frequency questionnaire every 4 years from which we calculated the Alternative Healthy Eating Index (aHEI-2010), Alternate Mediterranean Diet (AMED) and Dietary Approaches to Stop Hypertension (DASH) dietary pattern scores. Weight, lifestyle and health-related outcomes were self-reported every 2 years. We estimated the change in dietary score with change in body weight using linear regression models adjusting for age, baseline body mass index (BMI), baseline and simultaneous change in physical activity and smoking status and other risk factors. Women were followed up to 20 years, gaining an average 1.9 kg (s.d.=7.0) per 4-year period. Women in the highest quintile (Q5) of diet change (most improvement in quality) gained significantly less weight per 4-year period than the lowest quintile (Q1; decrease in quality), independent of other risk factors (4-year weight change, aHEI-2010: Q5=1.30 kg vs Q1=3.27 kg; AMED: Q5=0.94 kg vs Q1=2.56 kg, DASH: Q5=0.64 kg vs Q1=2.75 kg). Significant effect modification by BMI (p-interactions <0.001) indicated a greater magnitude of weight change among women with a higher baseline BMI for all three patterns. Increased diet quality was associated with less weight gain, independent of other lifestyle factors. Post-partum recommendations on diet quality may provide one strategy to prevent long-term weight gain in this high-risk group.

  19. The advantages of absorbed-dose calibration factors.

    PubMed

    Rogers, D W

    1992-01-01

    A formalism for clinical external beam dosimetry based on use of ion chamber absorbed-dose calibration factors is outlined in the context and notation of the AAPM TG-21 protocol. It is shown that basing clinical dosimetry on absorbed-dose calibration factors ND leads to considerable simplification and reduced uncertainty in dose measurement. In keeping with a protocol which is used in Germany, a quantity kQ is defined which relates an absorbed-dose calibration factor in a beam of quality Q0 to that in a beam of quality Q. For 38 cylindrical ion chambers, two sets of values are presented for ND/NX and Ngas/ND and for kQ for photon beams with beam quality specified by the TPR20(10) ratio. One set is based on TG-21's protocol to allow the new formalism to be used while maintaining equivalence to the TG-21 protocol. To demonstrate the magnitude of the overall error in the TG-21 protocol, the other set uses corrected versions of the TG-21 equations and the more consistent physical data of the IAEA Code of Practice. Comparisons are made to procedures based on air-kerma or exposure calibration factors and it is shown that accuracy and simplicity are gained by avoiding the determination of Ngas from NX. It is also shown that the kQ approach simplifies the use of plastic phantoms in photon beams since kQ values change by less than 0.6% compared to those in water although an overall correction factor of 0.973 is needed to go from absorbed dose in water calibration factors to those in PMMA or polystyrene. Values of kQ calculated using the IAEA Code of Practice are presented but are shown to be anomalous because of the way the effective point of measurement changes for 60Co beams. In photon beams the major difference between the IAEA Code of Practice and the corrected AAPM TG-21 protocol is shown to be the Prepl correction factor. Calculated kQ curves and three parameter equations for them are presented for each wall material and are shown to represent accurately the kQ curve for all ion chambers in this study with a wall of that specified material and a thickness less than 0.25 g/cm2. Values of kQ can be measured using the primary standards for absorbed dose in photon beams.

  20. Region-specific S-wave attenuation for earthquakes in northwestern Iran

    NASA Astrophysics Data System (ADS)

    Heidari, Reza; Mirzaei, Noorbakhsh

    2017-11-01

    In this study, continuous wavelet transform is applied to estimate the frequency-dependent quality factor of shear waves, Q S , in northwestern Iran. The dataset used in this study includes velocigrams of more than 50 events with magnitudes between 4.0 and 6.5, which have occurred in the study area. The CWT-based method shows a high-resolution technique for the estimation of S-wave frequency-dependent attenuation. The quality factor values are determined in the form of a power law as Q S ( f) = (147 ± 16) f 0.71 ± 0.02 and (126 ± 12) f 0.73 ± 0.02 for vertical and horizontal components, respectively, where f is between 0.9 and 12 Hz. Furthermore, in order to verify the reliability of the suggested Q S estimator method, an additional test is performed by using accelerograms of Ahar-Varzaghan dual earthquakes on August 11, 2012, of moment magnitudes 6.4 and 6.3 and their aftershocks. Results indicate that the estimated Q S values from CWT-based method are not very sensitive to the numbers and types of waveforms used (velocity or acceleration).

  1. On the impact of ICRU report 90 recommendations on kQ factors for high-energy photon beams.

    PubMed

    Mainegra-Hing, Ernesto; Muir, Bryan R

    2018-06-03

    To assess the impact of the ICRU report 90 recommendations on the beam-quality conversion factor, k Q , used for clinical reference dosimetry of megavoltage linac photon beams. The absorbed dose to water and the absorbed dose to the air in ionization chambers representative of those typically used for linac photon reference dosimetry are calculated at the reference depth in a water phantom using Monte Carlo simulations. Depth-dose calculations in water are also performed to investigate changes in beam quality specifiers. The calculations are performed in a cobalt-60 beam and MV photon beams with nominal energy between 6 MV and 25 MV using the EGSnrc simulation toolkit. Inputs to the calculations use stopping-power data for graphite and water from the original ICRU-37 report and the new proposed values from the recently published ICRU-90 report. Calculated k Q factors are compared using the two different recommendations for key dosimetry data and measured k Q factors. Less than about 0.1% effects from ICRU-90 recommendations on the beam quality specifiers, the photon component of the percentage depth-dose at 10 cm, %dd(10) x , and the tissue-phantom ratio at 20 cm and 10 cm, TPR1020, are observed. Although using different recommendations for key dosimetric data impact water-to-air stopping-power ratios and ion chamber perturbation corrections by up to 0.54% and 0.40%, respectively, we observe little difference (≤0.14%) in calculated k Q factors. This is contradictory to the predictions in ICRU-90 that suggest differences up to 0.5% in high-energy photon beams. A slightly better agreement with experimental values is obtained when using ICRU-90 recommendations. Users of the addendum to the TG-51 protocol for reference dosimetry of high-energy photon beams, which recommends Monte Carlo calculated k Q factors, can rest assured that the recommendations of ICRU report 90 on basic data have little impact on this central dosimetric parameter. © Her Majesty the Queen in Right of Canada 2018. Reproduced with the permission of the Minister of Science.

  2. Psychometrican analysis and dimensional structure of the Brazilian version of melasma quality of life scale (MELASQoL-BP)*

    PubMed Central

    Maranzatto, Camila Fernandes Pollo; Miot, Hélio Amante; Miot, Luciane Donida Bartoli; Meneguin, Silmara

    2016-01-01

    Background Although asymptomatic, melasma inflicts significant impact on quality of life. MELASQoL is the main instrument used to assess quality of life associated with melasma, it has been validated in several languages, but its latent dimensional structure and psychometric properties haven´t been fully explored. Objectives To evaluate psychometric characteristics, information and dimensional structure of the Brazilian version of MELASQoL. Methods Survey with patients with facial melasma through socio-demographic questionnaire, DLQI-BRA, MASI and MELASQoL-BP, exploratory and confirmatory factor analysis, internal consistency of MELASQoL and latent dimensions (Cronbach's alpha). The informativeness of the model and items were investigated by the Rasch model (ordinal data). Results We evaluated 154 patients, 134 (87%) were female, mean age (± SD) of 39 (± 8) years, the onset of melasma at 27 (± 8) years, median (p25-p75) of MASI scores , DLQI and MELASQoL 8 (5-15) 2 (1-6) and 30 (17-44). The correlation (rho) of MELASQoL with DLQI and MASI were: 0.70 and 0.36. Exploratory factor analysis identified two latent dimensions: Q1-Q3 and Q4-Q10, which had significantly more adjusted factor structure than the one-dimensional model: Χ2 / gl = 2.03, CFI = 0.95, AGFI = 0.94, RMSEA = 0.08. Cronbach's coefficient for the one-dimensional model and the factors were: 0.95, 0.92 and 0.93. Rasch analysis demonstrated that the use of seven alternatives per item resulted in no increase in the model informativeness. Conclusions MELASQoL-BP showed good psychometric performance and a latent structure of two dimensions. We also identified an oversizing of item alternatives to characterize the aggregate information to each dimension. PMID:27579735

  3. On Strong Positive Frequency Dependencies of Quality Factors in Local-Earthquake Seismic Studies

    NASA Astrophysics Data System (ADS)

    Morozov, Igor B.; Jhajhria, Atul; Deng, Wubing

    2018-03-01

    Many observations of seismic waves from local earthquakes are interpreted in terms of the frequency-dependent quality factor Q( f ) = Q0 f^{η } , where η is often close to or exceeds one. However, such steep positive frequency dependencies of Q require careful analysis with regard to their physical consistency. In particular, the case of η = 1 corresponds to frequency-independent (elastic) amplitude decays with time and consequently requires no Q-type attenuation mechanisms. For η > 1, several problems with physical meanings of such Q-factors occur. First, contrary to the key premise of seismic attenuation, high-frequency parts of the wavefield are enhanced with increasing propagation times relative to the low-frequency ones. Second, such attenuation cannot be implemented by mechanical models of wave-propagating media. Third, with η > 1, the velocity dispersion associated with such Q(f) occurs over unrealistically short frequency range and has an unexpected oscillatory shape. Cases η = 1 and η > 1 are usually attributed to scattering; however, this scattering must exhibit fortuitous tuning into the observation frequency band, which appears unlikely. The reason for the above problems is that the inferred Q values are affected by the conventional single-station measurement procedure. Both parameters Q 0 and are apparent, i.e., dependent on the selected parameterization and inversion method, and they should not be directly attributed to the subsurface. For η ≈ 1, parameter Q 0 actually describes the frequency-independent amplitude decay in access of some assumed geometric spreading t -α , where α is usually taken equal one. The case η > 1 is not allowed physically and could serve as an indicator of problematic interpretations. Although the case 0 < η < 1 is possible, its parameters Q 0 and may also be biased by the measurement procedure. To avoid such difficulties of Q-based approaches, we recommend measuring and interpreting the amplitude-decay rates (such as parameter α) directly.

  4. Combination of classical test theory (CTT) and item response theory (IRT) analysis to study the psychometric properties of the French version of the Quality of Life Enjoyment and Satisfaction Questionnaire-Short Form (Q-LES-Q-SF).

    PubMed

    Bourion-Bédès, Stéphanie; Schwan, Raymund; Epstein, Jonathan; Laprevote, Vincent; Bédès, Alex; Bonnet, Jean-Louis; Baumann, Cédric

    2015-02-01

    The study aimed to examine the construct validity and reliability of the Quality of Life Enjoyment and Satisfaction Questionnaire-Short Form (Q-LES-Q-SF) according to both classical test and item response theories. The psychometric properties of the French version of this instrument were investigated in a cross-sectional, multicenter study. A total of 124 outpatients with a substance dependence diagnosis participated in the study. Psychometric evaluation included descriptive analysis, internal consistency, test-retest reliability, and validity. The dimensionality of the instrument was explored using a combination of the classical test, confirmatory factor analysis (CFA), and an item response theory analysis, the Person Separation Index (PSI), in a complementary manner. The results of the Q-LES-Q-SF revealed that the questionnaire was easy to administer and the acceptability was good. The internal consistency and the test-retest reliability were 0.9 and 0.88, respectively. All items were significantly correlated with the total score and the SF-12 used in the study. The CFA with one factor model was good, and for the unidimensional construct, the PSI was found to be 0.902. The French version of the Q-LES-Q-SF yielded valid and reliable clinical assessments of the quality of life for future research and clinical practice involving French substance abusers. In response to recent questioning regarding the unidimensionality or bidimensionality of the instrument and according to the underlying theoretical unidimensional construct used for its development, this study suggests the Q-LES-Q-SF as a one-dimension questionnaire in French QoL studies.

  5. Q-values for P and S waves in Southern Sinai and Southern Gulf of Suez Region, Egypt

    NASA Astrophysics Data System (ADS)

    Mohamed, Gad-Elkareem A.

    2014-05-01

    The quality factor Q has been estimated using spectral amplitudes of P and S waves from earthquakes recorded by the seismic network of the Egyptian National Seismological Network (ENSN) in southern Sinai and southern Gulf of Suez region. The earthquakes recorded at nine stations - DHA, NUB, TR1, TR2, KAT, SH2, GRB, HRG and SFG have been used in this study. The spectral amplitude ratios have been calculated between 2 - 20 Hz and single station spectral ratio method has been applied for this purpose. The results show that the quality factors for both P and S waves (Qp and Qs) increase as a function of frequency according to law the Q = Q0fn. By averaging the estimated Q- Value obtained at all stations we calculated the average attenuation laws: Qp = (13.15± 0.76) f0.95± 0.19 and Qs = (20.05± 0.79) f1.03±0.04 for P and S waves respectively. These relations are useful for the estimation of source parameters of earthquakes and simulation of earthquake strong ground motions. The QS /QP ratio for KAT station is less than 1 at lower frequencies, whereas at HRG and SH2 stations QS /QP ratio is are greater than 1.

  6. Measured and Monte Carlo calculated k{sub Q} factors: Accuracy and comparison

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muir, B. R.; McEwen, M. R.; Rogers, D. W. O.

    2011-08-15

    Purpose: The journal Medical Physics recently published two papers that determine beam quality conversion factors, k{sub Q}, for large sets of ion chambers. In the first paper [McEwen Med. Phys. 37, 2179-2193 (2010)], k{sub Q} was determined experimentally, while the second paper [Muir and Rogers Med. Phys. 37, 5939-5950 (2010)] provides k{sub Q} factors calculated using Monte Carlo simulations. This work investigates a variety of additional consistency checks to verify the accuracy of the k{sub Q} factors determined in each publication and a comparison of the two data sets. Uncertainty introduced in calculated k{sub Q} factors by possible variation ofmore » W/e with beam energy is investigated further. Methods: The validity of the experimental set of k{sub Q} factors relies on the accuracy of the NE2571 reference chamber measurements to which k{sub Q} factors for all other ion chambers are correlated. The stability of NE2571 absorbed dose to water calibration coefficients is determined and comparison to other experimental k{sub Q} factors is analyzed. Reliability of Monte Carlo calculated k{sub Q} factors is assessed through comparison to other publications that provide Monte Carlo calculations of k{sub Q} as well as an analysis of the sleeve effect, the effect of cavity length and self-consistencies between graphite-walled Farmer-chambers. Comparison between the two data sets is given in terms of the percent difference between the k{sub Q} factors presented in both publications. Results: Monitoring of the absorbed dose calibration coefficients for the NE2571 chambers over a period of more than 15 yrs exhibit consistency at a level better than 0.1%. Agreement of the NE2571 k{sub Q} factors with a quadratic fit to all other experimental data from standards labs for the same chamber is observed within 0.3%. Monte Carlo calculated k{sub Q} factors are in good agreement with most other Monte Carlo calculated k{sub Q} factors. Expected results are observed for the sleeve effect and the effect of cavity length on k{sub Q}. The mean percent differences between experimental and Monte Carlo calculated k{sub Q} factors are -0.08, -0.07, and -0.23% for the Elekta 6, 10, and 25 MV nominal beam energies, respectively. An upper limit on the variation of W/e in photon beams from cobalt-60 to 25 MV is determined as 0.4% with 95% confidence. The combined uncertainty on Monte Carlo calculated k{sub Q} factors is reassessed and amounts to between 0.40 and 0.49% depending on the wall material of the chamber. Conclusions: Excellent agreement (mean percent difference of only 0.13% for the entire data set) between experimental and calculated k{sub Q} factors is observed. For some chambers, k{sub Q} is measured for only one chamber of each type--the level of agreement observed in this study would suggest that for those chambers the measured k{sub Q} values are generally representative of the chamber type.« less

  7. DOSIMETRIC response of a REM-500 in low energy neutron fields typical of nuclear power plants.

    PubMed

    Aslam; Matysiak, W; Atanackovic, J; Waker, A J

    2012-06-01

    This study investigates the response of a REM-500 to assess neutron quality factor and dose equivalent in low energy neutron fields, which are commonly encountered in the workplace environment of nuclear power stations. The McMaster University 3 MV Van de Graaff accelerator facility was used to measure the response of the instrument in monoenergetic neutron fields in the energy range 51 to 727 keV by bombarding a thin LiF target with 1.93-2.50 MeV protons. The energy distribution of the neutron fields produced in the facility was measured by a (3)He filled gas ionization chamber. The MCA mode of the REM-500 instrument was used to collect lineal energy distributions at varying neutron energies and to calculate the frequency and dose-mean lineal energies. The effective quality factor, Q-, was also calculated using the values of Q(y)listed in the REM-500 operation manual and compared with those of ICRP 60. The authors observed a continuously increasing trend in y - F, y-D, and Q-with an increase in neutron energy. It is interesting to note that standard tissue equivalent proportional counters (TEPCs) filled with tissue equivalent(TE) gas give rise to a similar trend for these microdosimetric quantities of interest in the same energy range; however, the averages calculated in this study are larger by about 15%compared to a TEPC filled with propane-based TE gas probably because of the larger stopping power of protons in propane compared to TE gas. These somewhat larger event sizes did not result in any significant increase in the Q-compared to those obtained from a TEPC filled with TE gas and were found to be in good agreement with other measurements reported earlier at corresponding neutron energies. The instrument quality factor response, R(Q), defined as the ratio of measured quality factor to the calculated quality factor in an ICRU tissue sphere,was found to vary with neutron energy. The instrument response,R(Q), was ~0.6 at 727 keV, which deteriorates further to ~0.3 at 51 keV neutron energy. The counter response based on ICRP 60 was comparable to an ideal response of 1.0 above 600 keV, which dropped to ~0.8 at 159 keV and ~0.4 at 51 keV neutron energy. The decline in counter quality factor response based on ICRP 60 was found to be much steeper than that when using the instrument’s built-in function for quality factor.The REM-500 measures a dose equivalent at 727 keV,which is 60% of the ambient dose equivalent, 40% at 159 keV,and 15% at 51 keV. Two algorithms have been developed, one for real time measurement and another to be used post measurement,and their efficacy is demonstrated in determining the quality factor and the ambient dose equivalent in low energy neutron fields, which are typical for the workplace environment in CANDU® nuclear power generating stations.

  8. Experimental validation of beam quality correction factors for proton beams

    NASA Astrophysics Data System (ADS)

    Gomà, Carles; Hofstetter-Boillat, Bénédicte; Safai, Sairos; Vörös, Sándor

    2015-04-01

    This paper presents a method to experimentally validate the beam quality correction factors (kQ) tabulated in IAEA TRS-398 for proton beams and to determine the kQ of non-tabulated ionization chambers (based on the already tabulated values). The method is based exclusively on ionometry and it consists in comparing the reading of two ionization chambers under the same reference conditions in a proton beam quality Q and a reference beam quality 60Co. This allows one to experimentally determine the ratio between the kQ of the two ionization chambers. In this work, 7 different ionization chamber models were irradiated under the IAEA TRS-398 reference conditions for 60Co beams and proton beams. For the latter, the reference conditions for both modulated beams (spread-out Bragg peak field) and monoenergetic beams (pseudo-monoenergetic field) were studied. For monoenergetic beams, it was found that the experimental kQ values obtained for plane-parallel chambers are consistent with the values tabulated in IAEA TRS-398; whereas the kQ values obtained for cylindrical chambers are not consistent—being higher than the tabulated values. These results support the suggestion (of previous publications) that the IAEA TRS-398 reference conditions for monoenergetic proton beams should be revised so that the effective point of measurement of cylindrical ionization chambers is taken into account when positioning the reference point of the chamber at the reference depth. For modulated proton beams, the tabulated kQ values of all the ionization chambers studied in this work were found to be consistent with each other—except for the IBA FC65-G, whose experimental kQ value was found to be 0.6% lower than the tabulated one. The kQ of the PTW Advanced Markus chamber, which is not tabulated in IAEA TRS-398, was found to be 0.997 ± 0.042 (k = 2), based on the tabulated value of the PTW Markus chamber.

  9. Systematic reviews and meta-analyses on psoriasis: role of funding sources, conflict of interest and bibliometric indices as predictors of methodological quality.

    PubMed

    Gómez-García, F; Ruano, J; Aguilar-Luque, M; Gay-Mimbrera, J; Maestre-Lopez, B; Sanz-Cabanillas, J L; Carmona-Fernández, P J; González-Padilla, M; Vélez García-Nieto, A; Isla-Tejera, B

    2017-06-01

    The quality of systematic reviews and meta-analyses on psoriasis, a chronic inflammatory skin disease that severely impairs quality of life and is associated with high costs, remains unknown. To assess the methodological quality of systematic reviews published on psoriasis. After a comprehensive search in MEDLINE, Embase and the Cochrane Database (PROSPERO: CDR42016041611), the quality of studies was assessed by two raters using the Assessment of Multiple Systematic Reviews (AMSTAR) tool. Article metadata and journal-related bibliometric indices were also obtained. Systematic reviews were classified as low (0-4), moderate (5-8) or high (9-11) quality. A prediction model for methodological quality was fitted using principal component and multivariate ordinal logistic regression analyses. We classified 220 studies as high (17·2%), moderate (55·0%) or low (27·8%) quality. Lower compliance rates were found for AMSTAR question (Q)5 (list of studies provided, 11·4%), Q10 (publication bias assessed, 27·7%), Q4 (status of publication included, 39·5%) and Q1 (a priori design provided, 40·9%). Factors such as meta-analysis inclusion [odds ratio (OR) 6·22; 95% confidence interval (CI) 2·78-14·86], funding by academic institutions (OR 2·90, 95% CI 1·11-7·89), Article Influence score (OR 2·14, 95% CI 1·05-6·67), 5-year impact factor (OR 1·34, 95% CI 1·02-1·40) and article page count (OR 1·08, 95% CI 1·02-1·15) significantly predicted higher quality. A high number of authors with a conflict of interest (OR 0·90, 95% CI 0·82-0·99) was significantly associated with lower quality. The methodological quality of systematic reviews published about psoriasis remains suboptimal. The type of funding sources and author conflicts may compromise study quality, increasing the risk of bias. © 2017 British Association of Dermatologists.

  10. Calculation of k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} for several small detectors and for two linear accelerators using Monte Carlo simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Francescon, P.; Cora, S.; Satariano, N.

    2011-12-15

    Purpose: The scope of this study was to determine a complete set of correction factors for several detectors in static small photon fields for two linear accelerators (linacs) and for several detectors. Methods: Measurements for Monte Carlo (MC) commissioning were performed for two linacs, Siemens Primus and Elekta Synergy. After having determined the source parameters that best fit the measurements of field specific output factors, profiles, and tissue-phantom ratio, the generalized version of the classical beam quality correction factor for static small fields, k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}},more » were determined for several types of detectors by using the egs{sub c}hamber Monte Carlo user code which can accurately reproduce the geometry and the material composition of the detector. The influence of many parameters (energy and radial FWHM of the electron beam source, field dimensions, type of accelerator) on the value of k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} was evaluated. Moreover, a MC analysis of the parameters that influence the change of k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} as a function of field dimension was performed. A detailed analysis of uncertainties related to the measurements of the field specific output factor and to the Monte Carlo calculation of k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} was done. Results: The simulations demonstrated that the correction factor k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} can be considered independent from the quality beam factor Q in the range 0.68 {+-} 0.01 for all the detectors analyzed. The k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} of PTW 60012 and EDGE diodes can be assumed dependent only on the field size, for fields down to 0.5 x 0.5 cm{sup 2}. The microLion, and the microchambers, instead, must be used with some caution because they exhibit a slight dependence on the radial FWHM of the electron source, and therefore, a correction factor only dependent on field size can be used for fields {>=}0.75 x 0.75 and {>=}1.0 x 1.0 cm{sup 2}, respectively. The analysis of uncertainties gave an estimate of uncertainty for the 0.5 x 0.5 cm{sup 2} field of about 0.7% (1{sigma}) for k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} factor and of about 1.0% (1{sigma}) for the field output factor, {Omega}{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}}, of diodes, microchambers, and microLion. Conclusions: Stereotactic diodes with the appropriate k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} are recommended for determining {Omega}{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} of small photon beams.« less

  11. Children's perception on obesity and quality of life: a Mexican survey.

    PubMed

    Rendón-Macías, Mario-Enrique; Rosas-Vargas, Haydeé; Villasís-Keever, Miguel-Ángel; Pérez-García, Celia

    2014-05-29

    Child obesity has become a major health problem worldwide. In order to design successful intervention strategies, it is necessary to understand how children perceive obesity and its consequences. With the aim to evaluate scholar children perception of obesity as a significant factor on the quality of life, we developed and validated the "Obesity impact on the quality of life perception-questionnaire" (ObI-Q). We surveyed 1335 healthy children aged 6-12 years, randomly selected from elementary schools in Mexico City. The ObI-Q comprises eight multiple-choice items that explore aspects related to the quality of life during adult life; such as health, life span, emotional status, lifestyle, social recognition and economic status. In order to identify perceptional modifier factors, results were analyzed through multivariable logistic regression. Variables included gender, age, and child nutritional status, as well as the child's perception of parental nutritional status. ObI-Q results showed that most children (64.71%) considered obesity as a negative condition that influences health and social performance. This perception was inversely related to age (OR = 0.64, p = 0.003), as well as to the perception of their mother nutritional status (OR = 0.47, p = 0.01). This study provides an overview of children's perception on obesity and its consequences. Because the high proportion of schoolchildren who do not view obesity as an adverse consequence to the quality of life, then the results of this study could be used as part of strategies for the prevention of overweight and obesity.

  12. Monte Carlo calculations of k{sub Q}, the beam quality conversion factor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muir, B. R.; Rogers, D. W. O.

    2010-11-15

    Purpose: To use EGSnrc Monte Carlo simulations to directly calculate beam quality conversion factors, k{sub Q}, for 32 cylindrical ionization chambers over a range of beam qualities and to quantify the effect of systematic uncertainties on Monte Carlo calculations of k{sub Q}. These factors are required to use the TG-51 or TRS-398 clinical dosimetry protocols for calibrating external radiotherapy beams. Methods: Ionization chambers are modeled either from blueprints or manufacturers' user's manuals. The dose-to-air in the chamber is calculated using the EGSnrc user-code egs{sub c}hamber using 11 different tabulated clinical photon spectra for the incident beams. The dose to amore » small volume of water is also calculated in the absence of the chamber at the midpoint of the chamber on its central axis. Using a simple equation, k{sub Q} is calculated from these quantities under the assumption that W/e is constant with energy and compared to TG-51 protocol and measured values. Results: Polynomial fits to the Monte Carlo calculated k{sub Q} factors as a function of beam quality expressed as %dd(10){sub x} and TPR{sub 10}{sup 20} are given for each ionization chamber. Differences are explained between Monte Carlo calculated values and values from the TG-51 protocol or calculated using the computer program used for TG-51 calculations. Systematic uncertainties in calculated k{sub Q} values are analyzed and amount to a maximum of one standard deviation uncertainty of 0.99% if one assumes that photon cross-section uncertainties are uncorrelated and 0.63% if they are assumed correlated. The largest components of the uncertainty are the constancy of W/e and the uncertainty in the cross-section for photons in water. Conclusions: It is now possible to calculate k{sub Q} directly using Monte Carlo simulations. Monte Carlo calculations for most ionization chambers give results which are comparable to TG-51 values. Discrepancies can be explained using individual Monte Carlo calculations of various correction factors which are more accurate than previously used values. For small ionization chambers with central electrodes composed of high-Z materials, the effect of the central electrode is much larger than that for the aluminum electrodes in Farmer chambers.« less

  13. TH-CD-BRA-03: Direct Measurement of Magnetic Field Correction Factors, KQB, for Application in Future Codes of Practice for Reference Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wolthaus, J; Asselen, B van; Woodings, S

    2016-06-15

    Purpose: With an MR-linac, radiation is delivered in the presence of a magnetic field. Modifications in the codes of practice (CoPs) for reference dosimetry are required to incorporate the effect of the magnetic field. Methods: In most CoPs the absorbed dose is determined using the well-known kQ formalism as the product of the calibration coefficient, the corrected electrometer reading and kQ, to account for the difference in beam quality. To keep a similar formalism a single correction factor is introduced which replaces kQ, and which corrects for beam quality and B-field, kQ,B. In this study we propose a method tomore » determine kQ,B under reference conditions in the MRLinac without using a primary standard, as the product of:- the ratio between detector readings without and with B-field (kB),- the ratio between doses in the point of measurement with and without B-field (rho),- kQ in the absence of the B-field in the MRLinac beam (kQmrl0,Q0),The ratio of the readings, which covers the change in detector reading due to the different electron trajectories in the detector, was measured with a waterproof ionization chamber (IBA-FC65g) in a water phantom in the MRLinac without and with B-field. The change in dose-to-water in the point of measurement due to the B-field was determined with a Monte Carlo based TPS. Results: For the presented approach, the measured ratio of readings is 0.956, the calculated ratio of doses in the point of measurement is 0.995. Based on TPR20,10 measurements kQ was calculated as 0.989 using NCS-18. This yields a value of 0.9408 for kQ,B. Conclusion: The presented approach to determine kQ,B agrees with a method based on primary standards within 0.4% with an uncertainty of 1% (1 std.uncert). It differs from a similar approach using a PMMA-phantom and an NE2571 chamber with 1.3%.« less

  14. Frequency-dependent Lg Q within the continental United States

    USGS Publications Warehouse

    Erickson, D.; McNamara, D.E.; Benz, H.M.

    2004-01-01

    Frequency-dependent crustal attenuation (1/Q) is determined for seven distinct physiographic/tectonic regions of the continental United States using high-quality Lg waveforms recorded on broadband stations in the frequency band 0.5 to 16 Hz. Lg attenuation is determined from time-domain amplitude measurements in one-octave frequency bands centered on the frequencies 0.75, 1.0, 3.0, 6.0, and 12.0 Hz. Modeling errors are determined using a delete-j jackknife resampling technique. The frequency-dependent quality factor is modeled in the form of Q = Q0 fη. Regions were initially selected based on tectonic provinces but were eventually limited and adjusted to maximize ray path coverage in each area. Earthquake data was recorded on several different networks and constrained to events occurring within the crust (<40 km depth) and at least mb 3.5 in size. A singular value decomposition inversion technique was applied to the data to simultaneously solve for source and receiver terms along with Q for each region at specific frequencies. The lowest crustal Q was observed in northern and southern California where Q is described by the functions Q = 152(±37)f0.72(±0.16) and Q = 105(±26)f0.67(±0.16), respectively. The Basin and Range Province, Pacific Northwest, and Rocky Mountain states also display lower Q and a strong frequency dependence characterized by the functions Q = 200(±40)f0.68(±0.12), Q = 152(±49)f0.76(±0.18), and Q = 166(±37)f0.61(±0.14), respectively. In contrast, in the central and northeast United States Q functions are Q = 640(±225)f0.344(±0.22) and Q = 650(±143)f0.36(±0.14), respectively, show a high crustal Q and a weaker frequency dependence. These results improve upon previous Lg modeling by subdividing the United States into smaller, distinct tectonic regions and using significantly more data that provide improved constraints on frequency-dependent attenuation and errors. A detailed attenuation map of the continental United States can provide significant input into hazard map mitigation. Both scattering and intrinsic attenuation mechanisms are likely to play a comparable role in the frequency range considered in the study.

  15. Temperature and frequency dependence of anelasticity in a nickel oscillator

    NASA Astrophysics Data System (ADS)

    Berg, Robert F.

    1995-09-01

    The frequency dependence of the real and imaginary parts of a nickel oscillator's transfer function is described over 3 decades in frequency by the use of simple expressions. These expressions incorporate only the resonance frequency ω0, the quality factor Q, and a characteristic exponent β determined by a single measurement of creep. They are based on the ansatz φ(ω)=Q-1(ω/ω0)-β, where φ is the imaginary part of the spring constant. Over a 100 K range of temperature T, the exponent β≂0.18 was constant even though Q(T) changed by a factor of 8. These expressions are potentially useful for accurately describing a mechanical oscillator whose transfer function must be modeled at frequencies far below ω0. Examples include accelerometers based on a flexure element and suspensions for interferometric gravitational wave detectors.

  16. Comparison of the mean quality factors for astronauts calculated using the Q-functions proposed by ICRP, ICRU, and NASA

    NASA Astrophysics Data System (ADS)

    Sato, T.; Endo, A.; Niita, K.

    2013-07-01

    For the estimation of the radiation risk for astronauts, not only the organ absorbed doses but also their mean quality factors must be evaluated. Three functions have been proposed by different organizations for expressing the radiation quality, including the Q(L), Q(y), and QNASA(Z, E) relationships as defined in International Committee of Radiological Protection (ICRP) Publication 60, International Commission on Radiation Units and Measurements (ICRU) Report 40, and National Aeronautics and Space Administration (NASA) TP-2011-216155, respectively. The Q(L) relationship is the most simple and widely used for space dosimetry, but the use of the latter two functions enables consideration of the difference in the track structure of various charged particles during the risk estimation. Therefore, we calculated the mean quality factors in organs and tissues in ICRP/ICRU reference voxel phantoms for the isotropic exposure to various mono-energetic particles using the three Q-functions. The Particle and Heavy Ion Transport code System PHITS was employed to simulate the particle motions inside the phantoms. The effective dose equivalents and the phantom-averaged effective quality factors for the astronauts were then estimated from the calculated mean quality factors multiplied by the fluence-to-dose conversion coefficients and cosmic-ray fluxes inside a spacecraft. It was found from the calculations that QNASA generally gives the largest values for the phantom-averaged effective quality factors among the three Q-functions for neutron, proton, and lighter-ion irradiation, whereas Q(L) provides the largest values for heavier-ion irradiation. Overall, the introduction of QNASA instead of Q(L) or Q(y) in astronaut dosimetry results in the increase the effective dose equivalents because the majority of the doses are composed of the contributions from protons and neutrons, although this tendency may change by the calculation conditions.

  17. Dosimetry for Small and Nonstandard Fields

    NASA Astrophysics Data System (ADS)

    Junell, Stephanie L.

    The proposed small and non-standard field dosimetry protocol from the joint International Atomic Energy Agency (IAEA) and American Association of Physicist in Medicine working group introduces new reference field conditions for ionization chamber based reference dosimetry. Absorbed dose beam quality conversion factors (kQ factors) corresponding to this formalism were determined for three different models of ionization chambers: a Farmer-type ionization chamber, a thimble ionization chamber, and a small volume ionization chamber. Beam quality correction factor measurements were made in a specially developed cylindrical polymethyl methacrylate (PMMA) phantom and a water phantom using thermoluminescent dosimeters (TLDs) and alanine dosimeters to determine dose to water. The TLD system for absorbed dose to water determination in high energy photon and electron beams was fully characterized as part of this dissertation. The behavior of the beam quality correction factor was observed as it transfers the calibration coefficient from the University of Wisconsin Accredited Dosimetry Calibration Laboratory (UWADCL) 60Co reference beam to the small field calibration conditions of the small field formalism. TLD-determined beam quality correction factors for the calibration conditions investigated ranged from 0.97 to 1.30 and had associated standard deviations from 1% to 3%. The alanine-determined beam quality correction factors ranged from 0.996 to 1.293. Volume averaging effects were observed with the Farmer-type ionization chamber in the small static field conditions. The proposed small and non-standard field dosimetry protocols new composite-field reference condition demonstrated its potential to reduce or remove ionization chamber volume dependancies, but the measured beam quality correction factors were not equal to the standard CoP's kQ, indicating a change in beam quality in the small and non-standard field dosimetry protocols new composite-field reference condition relative to the standard broad beam reference conditions. The TLD- and alanine-determined beam quality correction factors in the composite-field reference conditions were approximately 3% greater and differed by more than one standard deviation from the published TG-51 kQ values for all three chambers.

  18. Features of Radiation and Propagation of Seismic Waves in the Northern Caucasus: Manifestations in Regional Coda

    NASA Astrophysics Data System (ADS)

    Kromskii, S. D.; Pavlenko, O. V.; Gabsatarova, I. P.

    2018-03-01

    Based on the Anapa (ANN) seismic station records of 40 earthquakes ( M W > 3.9) that occurred within 300 km of the station since 2002 up to the present time, the source parameters and quality factor of the Earth's crust ( Q( f)) and upper mantle are estimated for the S-waves in the 1-8 Hz frequency band. The regional coda analysis techniques which allow separating the effects associated with seismic source (source effects) and with the propagation path of seismic waves (path effects) are employed. The Q-factor estimates are obtained in the form Q( f) = 90 × f 0.7 for the epicentral distances r < 120 km and in the form Q( f) = 90 × f1.0 for r > 120 km. The established Q( f) and source parameters are close to the estimates for Central Japan, which is probably due to the similar tectonic structure of the regions. The shapes of the source parameters are found to be independent of the magnitude of the earthquakes in the magnitude range 3.9-5.6; however, the radiation of the high-frequency components ( f > 4-5 Hz) is enhanced with the depth of the source (down to h 60 km). The estimates Q( f) of the quality factor determined from the records by the Sochi, Anapa, and Kislovodsk seismic stations allowed a more accurate determination of the seismic moments and magnitudes of the Caucasian earthquakes. The studies will be continued for obtaining the Q( f) estimates, geometrical spreading functions, and frequency-dependent amplification of seismic waves in the Earth's crust in the other regions of the Northern Caucasus.

  19. Laser Vision Correction with Q Factor Modification for Keratoconus Management.

    PubMed

    Pahuja, Natasha Kishore; Shetty, Rohit; Sinha Roy, Abhijit; Thakkar, Maithil Mukesh; Jayadev, Chaitra; Nuijts, Rudy Mma; Nagaraja, Harsha

    2017-04-01

    To evaluate the outcomes of corneal laser ablation with Q factor modification for vision correction in patients with progressive keratoconus. In this prospective study, 50 eyes of 50 patients were divided into two groups based on Q factor (>-1 in Group I and ≤-1 in Group II). All patients underwent a detailed ophthalmic examination including uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), subjective acceptance and corneal topography using the Pentacam. The topolyzer was used to measure the corneal asphericity (Q). Ablation was performed based on the preoperative Q values and thinnest pachymetry to obtain a target of near normal Q. This was followed by corneal collagen crosslinking to stabilize the progression. Statistically significant improvement (p ≤ 0.05) was noticed in refractive, topographic, and Q values posttreatment in both groups. The improvement in higher-order aberrations and total aberrations were statistically significant in both groups; however, the spherical aberration showed statistically significant improvement only in Group II. Ablation based on the preoperative Q and pachymetry for a near normal postoperative Q value appears to be an effective method to improve the visual acuity and quality in patients with keratoconus.

  20. High-Q silica zipper cavity for optical radiation pressure driven MOMS switch

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tetsumoto, Tomohiro; Tanabe, Takasumi, E-mail: takasumi@elec.keio.ac.jp

    2014-07-15

    We design a silica zipper cavity that has high optical and mechanical Q (quality factor) values and demonstrate numerically the feasibility of a radiation pressure driven micro opto-mechanical system (MOMS) directional switch. The silica zipper cavity has an optical Q of 4.0 × 10{sup 4} and an effective mode volume V{sub mode} of 0.67λ{sup 3} when the gap between two cavities is 34 nm. The mechanical Q (Q{sub m}) is determined by thermo-elastic damping and is 2.0 × 10{sup 6} in a vacuum at room temperature. The opto-mechanical coupling rate g{sub OM} is as high as 100 GHz/nm, which allowsmore » us to move the directional cavity-waveguide system and switch 1550-nm light with 770-nm light by controlling the radiation pressure.« less

  1. Analysis of Thickness and Quality factor of a Double Paddle Oscillator at Room Temperature.

    PubMed

    Shakeel, Hamza; Metcalf, Thomas H; Pomeroy, J M

    2016-01-01

    In this paper, we evaluate the quality (Q) factor and the resonance frequency of a double paddle oscillator (DPO) with different thickness using analytical, computational and experimental methods. The study is carried out for the 2 nd anti-symmetric resonance mode that provides extremely high experimental Q factors on the order of 10 5 . The results show that both the Q factor and the resonance frequency of a DPO increase with the thickness at room temperature.

  2. TH-CD-BRA-05: First Water Calorimetric Dw Measurement and Direct Measurement of Magnetic Field Correction Factors, KQ,B, in a 1.5 T B-Field of An MRI Linac

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prez, L de; Pooter, J de; Jansen, B

    2016-06-15

    Purpose: Reference dosimetry in MR-guided radiotherapy is performed in the presence of a B-field. As a consequence the response of ionization chambers changes considerably and depends on parameters not considered in traditional reference dosimetry. Therefore future Codes of Practices need ionization chamber correction factors to correct for both the change in beam quality and the presence of a B-field. The objective was to study the feasibility of water calorimetric absorbed-dose measurements in a 1.5 T B-field of an MRLinac and the direct measurement of kQ,B calibration of ionization chambers. Methods: Calorimetric absorbed dose to water Dw was measured with amore » new water calorimeter in the bore of an MRLinac (TPR20,10 of 0.702). Two waterproof ionization chambers (PTW 30013, IBA FC-65G) were calibrated inside the calorimeter phantom (ND,w,Q,B). Both measurements were normalized to a monitor ionization chamber. Ionization chamber measurements were corrected for conventional influence parameter. Based on the chambers’ Co-60 calibrations (ND,w,Q0), measured directly against the calorimeter. In this study the correction factors kQ,B was determined as the ratio of the calibration coefficients in the MRLinac and in Co-60. Additionally, kB was determined based on kQ values obtained with the IAEA TRS-398 Code of Practice. Results: The kQ,B factors of the ionization chambers mentioned above were respectively 0.9488(8) and 0.9445(8) with resulting kB factors of 0.961(13) and 0.952(13) with standard uncertainties on the least significant digit(s) between brackets. Conclusion: Calorimetric Dw measurements and calibration of waterproof ionization chambers were successfully carried out in the 1.5 T B-field of an MRLinac with a standard uncertainty of 0.7%. Preliminary kQ,B and kB factors were determined with standard uncertainties of respectively 0.8% and 1.3%. The kQ,B agrees with an alternative method within 0.4%. The feasibility of water calorimetry in the presence of B-fields was demonstrated by the direct determination of Dw and kQ,B. This work was supported by EMRP grant HLT06. The EMRP is jointly funded by the EMRP participating countries within EURAMET and the European Union.« less

  3. A radiation quality correction factor k for well-type ionization chambers for the measurement of the reference air kerma rate of (60)Co HDR brachytherapy sources.

    PubMed

    Schüller, Andreas; Meier, Markus; Selbach, Hans-Joachim; Ankerhold, Ulrike

    2015-07-01

    The aim of this study was to investigate whether a chamber-type-specific radiation quality correction factor kQ can be determined in order to measure the reference air kerma rate of (60)Co high-dose-rate (HDR) brachytherapy sources with acceptable uncertainty by means of a well-type ionization chamber calibrated for (192)Ir HDR sources. The calibration coefficients of 35 well-type ionization chambers of two different chamber types for radiation fields of (60)Co and (192)Ir HDR brachytherapy sources were determined experimentally. A radiation quality correction factor kQ was determined as the ratio of the calibration coefficients for (60)Co and (192)Ir. The dependence on chamber-to-chamber variations, source-to-source variations, and source strength was investigated. For the PTW Tx33004 (Nucletron source dosimetry system (SDS)) well-type chamber, the type-specific radiation quality correction factor kQ is 1.19. Note that this value is valid for chambers with the serial number, SN ≥ 315 (Nucletron SDS SN ≥ 548) onward only. For the Standard Imaging HDR 1000 Plus well-type chambers, the type-specific correction factor kQ is 1.05. Both kQ values are independent of the source strengths in the complete clinically relevant range. The relative expanded uncertainty (k = 2) of kQ is UkQ = 2.1% for both chamber types. The calibration coefficient of a well-type chamber for radiation fields of (60)Co HDR brachytherapy sources can be calculated from a given calibration coefficient for (192)Ir radiation by using a chamber-type-specific radiation quality correction factor kQ. However, the uncertainty of a (60)Co calibration coefficient calculated via kQ is at least twice as large as that for a direct calibration with a (60)Co source.

  4. Accurate Determination of the Q Quality Factor in Magnetoelastic Resonant Platforms for Advanced Biological Detection.

    PubMed

    Lopes, Ana Catarina; Sagasti, Ariane; Lasheras, Andoni; Muto, Virginia; Gutiérrez, Jon; Kouzoudis, Dimitris; Barandiarán, José Manuel

    2018-03-16

    The main parameters of magnetoelastic resonators in the detection of chemical (i.e., salts, gases, etc.) or biological (i.e., bacteria, phages, etc.) agents are the sensitivity S (or external agent change magnitude per Hz change in the resonance frequency) and the quality factor Q of the resonance. We present an extensive study on the experimental determination of the Q factor in such magnetoelastic resonant platforms, using three different strategies: (a) analyzing the real and imaginary components of the susceptibility at resonance; (b) numerical fitting of the modulus of the susceptibility; (c) using an exact mathematical expression for the real part of the susceptibility. Q values obtained by the three methods are analyzed and discussed, aiming to establish the most adequate one to accurately determine the quality factor of the magnetoelastic resonance.

  5. Accurate Determination of the Q Quality Factor in Magnetoelastic Resonant Platforms for Advanced Biological Detection

    PubMed Central

    Lopes, Ana Catarina; Sagasti, Ariane; Lasheras, Andoni; Muto, Virginia; Gutiérrez, Jon; Kouzoudis, Dimitris; Barandiarán, José Manuel

    2018-01-01

    The main parameters of magnetoelastic resonators in the detection of chemical (i.e., salts, gases, etc.) or biological (i.e., bacteria, phages, etc.) agents are the sensitivity S (or external agent change magnitude per Hz change in the resonance frequency) and the quality factor Q of the resonance. We present an extensive study on the experimental determination of the Q factor in such magnetoelastic resonant platforms, using three different strategies: (a) analyzing the real and imaginary components of the susceptibility at resonance; (b) numerical fitting of the modulus of the susceptibility; (c) using an exact mathematical expression for the real part of the susceptibility. Q values obtained by the three methods are analyzed and discussed, aiming to establish the most adequate one to accurately determine the quality factor of the magnetoelastic resonance. PMID:29547578

  6. Correlation between gamma glutamyltransferase fractions and bone quality.

    PubMed

    Franzini, M; Nesti, A; Panetta, D; Fierabracci, V; Marchetti, S; Parchi, P D; Caponi, L; Paolicchi, A; Musetti, V; Salvadori, P; Edmin, M; Pucci, A; Bonicoli, E; Scaglione, M; Piolanti, N

    Gamma-glutamyltransferase (GGT) has been recently identified as a bone-resorbing factor. The aim of this study was to investigate the association between plasma GGT fractions levels and bone quality. Plasma GGT fractions were analysed by gel-filtration chromatography. Bone quality was established quantitatively by two micro-CT derived microarchitectural parameters: the BV/TV (mineralised bone volume/total volume), and the SMI (structure model index) that describes the rod-like (low resistant) or plate-like (high-resistant) shape of bone trabeculae. We enrolled 93 patients hospitalised for elective total hip replacement (group Arthrosis, n=46) or for proximal femoral fracture (group Fracture, n=47). Patients within the first quartile of BV/TV (Q1, osteoporotic patients, n=6) showed higher levels of b-GGT fraction [median (min-max): 3.37 (1.42–6.81)] compared to patients with normal bone density (fourth quartile Q4, n=10; 1.40 (0.83–4.36); p=0.0393]. Also, according to SMI, b-GGT value was higher in the subgroup with bone fragility [Q1, n=8: 1.36 (0.43–4.36); Q4, n=8: 5.10 (1.4 –7.60); p=0.0117]. In conclusion, patients characterised by fragile bone structure showed specifically higher levels of plasma b-GGT activity thus suggesting fractional GGT analysis as a possible biomarker in the diagnosis of osteoporosis.

  7. A Thermoelastic Damping Model for the Cone Microcantilever Resonator with Circular Cross-section

    NASA Astrophysics Data System (ADS)

    Li, Pu; Zhou, Hongyue

    2017-07-01

    Microbeams with variable cross-section have been applied in Microelectromechanical Systems (MEMS) resonators. Quality factor (Q-factor) is an important factor evaluating the performance of MEMS resonators, and high Q-factor stands for the excellent performance. Thermoelastic damping (TED), which has been verified as a fundamental energy lost mechanism for microresonators, determines the upper limit of Q-factor. TED can be calculated by the Zener’s model and Lifshits and Roukes (LR) model. However, for microbeam resonators with variable cross-sections, these two models become invalid in some cases. In this work, we derived the TED model for cone microcantilever with circular cross-section that is a representative non-uniform microbeam. The comparison of results obtained by the present model and Finite Element Method (FEM) model proves that the present model is valid for predicting TED value for cone microcantilever with circular cross-section. The results suggest that the first-order natural frequencies and TED values of cone microcantilever are larger than those of uniform microbeam for large aspect ratios (l/r 0). In addition, the Debye peak value of a uniform microcantilever is equal to 0.5ΔE, while that of cone microcantilever is about 0.438ΔE.

  8. Lateral and depth variations of coda Q in the Zagros region of Iran

    NASA Astrophysics Data System (ADS)

    Irandoust, Mohsen Ahmadzadeh; Sobouti, Farhad; Rahimi, Habib

    2016-01-01

    We have analyzed more than 2800 local earthquakes recorded by the Iranian National Seismic Network (INSN) and the Iranian Seismological Center (IRSC) to estimate coda wave quality factor, Q c , in the Zagros fold and thrust belt and the Sanandaj-Sirjan metamorphic zone in Iran. We used the single backscattering model to investigate lateral and depth variations of Q c in the study region. In the interior of Zagros, no strong lateral variation in attenuation parameters is observed. In SE Zagros (the Bandar-Abbas region) where transition to the Makran subduction setting begins, the medium shows lower attenuation. The average frequency relations for the SSZ, the Bandar-Abbas region, and the Zagros are Q c = (124 ± 11) f 0.82 ± 0.04, Q c = (109 ± 2) f 0.99 ± 0.01, and Q c = (85 ± 5) f 1.06 ± 0.03, respectively. To investigate the depth variation of Q c , 18 time windows between 5 and 90 s and at two epicentral distance ranges of R < 100 km and 100 < R < 200 km were considered. It was observed that with increasing coda lapse time, Q 0 ( Q c at 1 Hz) and n (frequency dependence factor) show increasing and decreasing trends, respectively. Beneath the SSZ and at depths of about 50 to 80 km, there is a correlation between the reported low velocity medium and the observed sharp change in the trend of Q 0 and n curves. In comparison with results obtained in other regions of the Iranian plateau, the Zagros along with the Alborz Mountains in the north show highest attenuation of coda wave and strongest frequency dependence, an observation that reflects the intense seismicity and active faulting in these mountain ranges. We also observe a stronger depth dependence of attenuation in the Zagros and SSZ compared to central Iran, indicating a thicker lithosphere in the Zagros region than in central Iran.

  9. High quality factor graphene varactors for wireless sensing applications

    NASA Astrophysics Data System (ADS)

    Koester, Steven J.

    2011-10-01

    A graphene wireless sensor concept is described. By utilizing thin gate dielectrics, the capacitance in a metal-insulator-graphene structure varies with charge concentration through the quantum capacitance effect. Simulations using realistic structural and transport parameters predict quality factors, Q, >60 at 1 GHz. When placed in series with an ideal inductor, a resonant frequency tuning ratio of 25% (54%) is predicted for sense charge densities ranging from 0.32 to 1.6 μC/cm2 at an equivalent oxide thickness of 2.0 nm (0.5 nm). The resonant frequency has a temperature sensitivity, df/dT, less than 0.025%/K for sense charge densities >0.32 μC/cm2.

  10. Q factor limitation at short wavelength (around 300 nm) in III-nitride-on-silicon photonic crystal cavities

    NASA Astrophysics Data System (ADS)

    Tabataba-Vakili, Farsane; Roland, Iannis; Tran, Thi-Mo; Checoury, Xavier; El Kurdi, Moustafa; Sauvage, Sébastien; Brimont, Christelle; Guillet, Thierry; Rennesson, Stéphanie; Duboz, Jean-Yves; Semond, Fabrice; Gayral, Bruno; Boucaud, Philippe

    2017-09-01

    III-nitride-on-silicon L3 photonic crystal cavities with resonances down to 315 nm and quality factors (Q) up to 1085 at 337 nm have been demonstrated. The reduction of the quality factor with decreasing wavelength is investigated. Besides the quantum well absorption below 340 nm, a noteworthy contribution is attributed to the residual absorption present in thin AlN layers grown on silicon, as measured by spectroscopic ellipsometry. This residual absorption ultimately limits the Q factor to around 2000 at 300 nm when no active layer is present.

  11. Dietary fat intake and quality of life: the SUN project.

    PubMed

    Ruano, Cristina; Henriquez, Patricia; Bes-Rastrollo, Maira; Ruiz-Canela, Miguel; del Burgo, Cristina López; Sánchez-Villegas, Almudena

    2011-11-02

    Few studies have related nutritional factors with quality of life in healthy populations. The purpose of the study was to assess whether dietary fat intake is associated to mental and physical quality of life. This analysis included 8,430 participants from the SUN (Seguimiento Universidad de Navarra) Project. The intake of saturated fatty acids (SFA), polyunsaturated fatty acids (PUFA), trans unsaturated fatty acids (TFA), and monounsaturated fatty acids (MUFA) was assessed through a 136-item food frequency questionnaire at baseline. Quality of life was measured with the SF-36 Health Survey after 4 years of follow-up. Generalized Linear Models were fitted to assess the regression coefficients (b) and their 95% confidence intervals (95% CI) for the 8 domains of the SF-36 according to successive quintiles of each kind of fatty acids intake. The multivariate-adjusted models revealed a significant inverse association for SFA intake (in quintiles) and two of the physical domains (physical functioning and general health). E.g. for general health domain: (highest quintile of intake (Q5) vs. lowest quintile (Q1), b = -1.6; 95% CI = -3.1, -0.1. General health also showed a dose-response relationship (p for trend < 0.05). For TFA intake (in quintiles), a significant inverse association was found for most of the mental domains (vitality, social functioning and role emotional). E.g. for vitality domain (Q5) vs. (Q1), b = -2.0, 95% CI = -3.4 to -0.6. We also found an inverse association between TFA intake and the bodily pain domain: (Q5 vs. Q1), b = -2.6; 95% CI = -4.4 to -0.8, with a statistically significant dose-response relationship (p for trend < 0.05). Except for TFA intake and the mental domains, the rest of the associations were attenuated when we repeated the analysis adjusting for adherence to the Mediterranean diet. A detrimental relationship between TFA intake at baseline and most of the SF-36 mental domains measured 4 years later were found, whereas weak inverse associations were found for SFA intake and some physical domains.

  12. Understanding Quality Factor Degradation in Superconducting Niobium Cavities at Low Microwave Field Amplitudes

    DOE PAGES

    Romanenko, A.; Schuster, D. I.

    2017-12-28

    In niobium superconducting radio frequency (SRF) cavities for particle acceleration, a decrease of the quality factor at lower fields—a so-called low field Q slope or LFQS—has been a long-standing unexplained effect. By extending the high Q measurement techniques to ultralow fields, we discover two previously unknown features of the effect: (i) saturation at rf fields lower than E acc~0.1 MV/m; (ii) strong degradation enhancement by growing thicker niobium pentoxide. Our findings suggest that the LFQS may be caused by the two level systems in the natural niobium oxide on the inner cavity surface, thereby identifying a new source of residual resistance andmore » providing guidance for potential nonaccelerator low-field applications of SRF cavities.« less

  13. Understanding Quality Factor Degradation in Superconducting Niobium Cavities at Low Microwave Field Amplitudes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Romanenko, A.; Schuster, D. I.

    In niobium superconducting radio frequency (SRF) cavities for particle acceleration, a decrease of the quality factor at lower fields—a so-called low field Q slope or LFQS—has been a long-standing unexplained effect. By extending the high Q measurement techniques to ultralow fields, we discover two previously unknown features of the effect: (i) saturation at rf fields lower than E acc~0.1 MV/m; (ii) strong degradation enhancement by growing thicker niobium pentoxide. Our findings suggest that the LFQS may be caused by the two level systems in the natural niobium oxide on the inner cavity surface, thereby identifying a new source of residual resistance andmore » providing guidance for potential nonaccelerator low-field applications of SRF cavities.« less

  14. Psychometric properties of the Portuguese version of the Quality of Life Questionnaire (QOL-Q).

    PubMed

    Albuquerque, Cristina P

    2012-09-01

    This study analyzes the psychometric properties of the Portuguese version of the Quality of Life Questionnaire (QOL-Q; Quality of Life Questionnaire Manual - 1993 Manual and 2004 Revision. 2004, IDS Publishing Company, Worthington, OH; Schalock & Keith 2004). The analysis of the factorial structure was carried out on a sample of 304 adults with intellectual disabilities, through the use of confirmatory (CFA) and exploratory (EFA) factor analysis. The relationships of the QOL-Q with life satisfaction and self-concept measures were determined in groups composed of respectively 72 and 78 adults with intellectual disabilities. Confirmatory factorial analysis indicated a poor adjustment of the original factor structure to the Portuguese data. EFA indicated the existence of four factors, which include 30 items, and that were also supported by CFA. The total score of the QOL-Q revealed a reduced correlation with life satisfaction, and a moderate correlation with the self-concept. The Portuguese version of the QOL-Q shows satisfactory psychometric properties, but also some limitations. © 2012 Blackwell Publishing Ltd.

  15. Higher Dietary Cost Is Associated with Higher Diet Quality: A Cross-Sectional Study among Selected Malaysian Adults

    PubMed Central

    Pondor, Ibnteesam

    2017-01-01

    Food price is a determining factor of food choices; however its relationship with diet quality is unclear in Malaysia. This study aimed to examine socio-economic characteristics and daily dietary cost (DDC) in relation to diet quality in the state of Selangor, Malaysia. Dietary intake was assessed using a Food Frequency Questionnaire (FFQ) and diet quality was estimated using a Malaysian Healthy Eating Index (M-HEI). DDC in Malaysian Ringgit (RM) was calculated from dietary intake and national food prices. Linear regression models were fitted to determine associations between DDC and M-HEI scores and predictors of diet quality. The mean M-HEI score of respondents was 61.31 ± 10.88 and energy adjusted DDC was RM10.71/2000 kcal (USD 2.49). The highest quintile of adjusted DDC had higher M-HEI scores for all respondents (Q1: 57.14 ± 10.07 versus Q5: 63.26 ± 11.54, p = 0.001). There were also positive associations between DDC and M-HEI scores for fruits (p < 0.001) and vegetables (p = 0.017) for all respondents. Predictors of diet quality included carbohydrate (β = 0290; p < 0.001) and fat intakes (β = −0.242; p < 0.001) and energy adjusted DDC (β = 0.196; p < 0.001). Higher dietary cost is associated with healthy eating among Malaysian adults. PMID:28926947

  16. Higher Dietary Cost Is Associated with Higher Diet Quality: A Cross-Sectional Study among Selected Malaysian Adults.

    PubMed

    Pondor, Ibnteesam; Gan, Wan Ying; Appannah, Geeta

    2017-09-16

    Food price is a determining factor of food choices; however its relationship with diet quality is unclear in Malaysia. This study aimed to examine socio-economic characteristics and daily dietary cost (DDC) in relation to diet quality in the state of Selangor, Malaysia. Dietary intake was assessed using a Food Frequency Questionnaire (FFQ) and diet quality was estimated using a Malaysian Healthy Eating Index (M-HEI). DDC in Malaysian Ringgit (RM) was calculated from dietary intake and national food prices. Linear regression models were fitted to determine associations between DDC and M-HEI scores and predictors of diet quality. The mean M-HEI score of respondents was 61.31 ± 10.88 and energy adjusted DDC was RM10.71/2000 kcal (USD 2.49). The highest quintile of adjusted DDC had higher M-HEI scores for all respondents (Q1: 57.14 ± 10.07 versus Q5: 63.26 ± 11.54, p = 0.001). There were also positive associations between DDC and M-HEI scores for fruits ( p < 0.001) and vegetables ( p = 0.017) for all respondents. Predictors of diet quality included carbohydrate (β = 0290; p < 0.001) and fat intakes (β = -0.242; p < 0.001) and energy adjusted DDC (β = 0.196; p < 0.001). Higher dietary cost is associated with healthy eating among Malaysian adults.

  17. Physics of Bodily Tides in Terrestrial Planets and the Appropriate Scales of Dynamical Evolution

    DTIC Science & Technology

    2007-12-29

    ORGANIZATION NAME(S) AND ADDRESS(ES) U.S. Naval Observatory ,3450 Massachusetts Ave,Washington,DC,20392-5420 8. PERFORMING ORGANIZATION REPORT NUMBER 9...circumstances only the principal tidal frequency (4) will matter . 2. Quality Factor Q and the Geometric Lag Angle d [7] During tidal flexure, the...correct. The inaccuracy in notations has not prevented Bills et al. [2005] from arriving at a reasonable value of the Martian quality factor, 85.58 ± 0.37

  18. Oral Health Related Quality of Life among Tamil Speaking Adults Attending a Dental Institution in Chennai, Southern India.

    PubMed

    Appukuttan, Deva Priya; Tadepalli, Anupama; Victor, Dhayanand John; Dharuman, Smriti

    2016-10-01

    Oral Health-Related Quality of Life (OHRQoL) indicates an individual's perception of how their well-being and quality of life is influenced by oral health. It facilitates treatment planning, assessing patient centred treatment outcomes and satisfaction. The study aimed to identify the factors influencing OHRQoL among Tamil speaking South Indian adult population. Non-probability sampling was done and 199 subjects aged 20-70 years were recruited for this observational study. The subjects were requested to fill a survey form along with the validated Tamil General Oral Health Assessment Index (GOHAI-Tml) questionnaire in the waiting area following which clinical examination was done by a single experienced Periodontist. The mean score with standard deviation for physical dimension was 4.34±0.96, psychological dimension was 4.03±1.13 and pain was 4.05±1.09 on GOHAI. Greater impacts were seen for psychosocial dimensions like pleased with the appearance of teeth/denture Q7 (3.7±1.2), worried about the problems with teeth/denture Q9 (3.7±1) and pain or discomfort in teeth Q12 (3.8±1). Functions like swallowing Q3 (4.5±0.8) and speaking Q4 (4.6±0.7) were minimally affected. As age increased subjects perceived more negative impacts as indicated by lower ADD-GOHAI and higher SC-GOHAI scores (p<0.01). Subjects complaining of bad breath, bleeding gums and Temporomandibular Joint (TMJ) problems, reported poor OHRQoL (p<0.05). It was observed that as self-perceived oral and general health status deteriorated, OHRQoL also worsened (p<0.01). Subjects with missing teeth, cervical abrasion, restorations, gingival recession and mobility had more impacts on OHRQoL (p<0.05). Subjects diagnosed with periodontitis had lower OHRQoL as reported on the scale than gingivitis subjects (p<0.01). In this study minimal impact was seen in all the three dimensions assessed with GOHAI. Factors like age, education, employment status, income, self-reported oral health, self-perceived general health, satisfaction with oral health, perceived need for treatment and denture wearing status influenced perceived OHRQoL. Bad breath, bleeding gums, TMJ problems, more number of missing teeth, decayed teeth, cervical abrasion, gingival recession and mobility were associated with poor OHRQoL.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schüller, Andreas, E-mail: andreas.schueller@ptb.de; Meier, Markus; Selbach, Hans-Joachim

    Purpose: The aim of this study was to investigate whether a chamber-type-specific radiation quality correction factor k{sub Q} can be determined in order to measure the reference air kerma rate of {sup 60}Co high-dose-rate (HDR) brachytherapy sources with acceptable uncertainty by means of a well-type ionization chamber calibrated for {sup 192}Ir HDR sources. Methods: The calibration coefficients of 35 well-type ionization chambers of two different chamber types for radiation fields of {sup 60}Co and {sup 192}Ir HDR brachytherapy sources were determined experimentally. A radiation quality correction factor k{sub Q} was determined as the ratio of the calibration coefficients for {supmore » 60}Co and {sup 192}Ir. The dependence on chamber-to-chamber variations, source-to-source variations, and source strength was investigated. Results: For the PTW Tx33004 (Nucletron source dosimetry system (SDS)) well-type chamber, the type-specific radiation quality correction factor k{sub Q} is 1.19. Note that this value is valid for chambers with the serial number, SN ≥ 315 (Nucletron SDS SN ≥ 548) onward only. For the Standard Imaging HDR 1000 Plus well-type chambers, the type-specific correction factor k{sub Q} is 1.05. Both k{sub Q} values are independent of the source strengths in the complete clinically relevant range. The relative expanded uncertainty (k = 2) of k{sub Q} is U{sub k{sub Q}} = 2.1% for both chamber types. Conclusions: The calibration coefficient of a well-type chamber for radiation fields of {sup 60}Co HDR brachytherapy sources can be calculated from a given calibration coefficient for {sup 192}Ir radiation by using a chamber-type-specific radiation quality correction factor k{sub Q}. However, the uncertainty of a {sup 60}Co calibration coefficient calculated via k{sub Q} is at least twice as large as that for a direct calibration with a {sup 60}Co source.« less

  20. Frequency-constant Q, unity and disorder

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hargreaves, N.D.

    1995-12-31

    In exploration geophysics we obtain information about the earth by observing its response to different types of applied force. The response can cover the full range of possible Q values (where Q, the quality factor, is a measure of energy dissipation), from close to infinity in the case of deep crustal seismic to close to 0 in the case of many electromagnetic methods. When Q is frequency-constant, however, the various types of response have a common scaling behavior and can be described as being self-affine. The wave-equation then takes on a generalised form, changing from the standard wave-equation at Qmore » = {infinity} to the diffusion equation at Q = 0, via lossy, diffusive, propagation at intermediate Q values. Solutions of this wave-diffusion equation at any particular Q value can be converted to an equivalent set of results for any other Q value. In particular it is possible to convert from diffusive to wave propagation by a mapping from Q < {infinity} to Q = {infinity}. In the context of seismic sounding this is equivalent to applying inverse Q-filtering; in a more general context the mapping integrates different geophysical observations by referencing them to the common result at Q = {infinity}. The self-affinity of the observations for frequency-constant Q is an expression of scale invariance in the fundamental physical properties of the medium of propagation, this being the case whether the mechanism of diffusive propagation is scattering of intrinsic attenuation. Scale invariance, or fractal scaling, is a general property of disordered systems; the assumption of frequency-constant Q not only implies a unity between different geophysical observations, but also suggests that it is the disordered nature of the earth`s sub-surface that is the unifying factor.« less

  1. Sci-Thur PM: YIS - 07: Monte Carlo simulations to obtain several parameters required for electron beam dosimetry.

    PubMed

    Muir, B; Rogers, D; McEwen, M

    2012-07-01

    When current dosimetry protocols were written, electron beam data were limited and had uncertainties that were unacceptable for reference dosimetry. Protocols for high-energy reference dosimetry are currently being updated leading to considerable interest in accurate electron beam data. To this end, Monte Carlo simulations using the EGSnrc user-code egs_chamber are performed to extract relevant data for reference beam dosimetry. Calculations of the absorbed dose to water and the absorbed dose to the gas in realistic ion chamber models are performed as a function of depth in water for cobalt-60 and high-energy electron beams between 4 and 22 MeV. These calculations are used to extract several of the parameters required for electron beam dosimetry - the beam quality specifier, R 50 , beam quality conversion factors, k Q and k R50 , the electron quality conversion factor, k' R50 , the photon-electron conversion factor, k ecal , and ion chamber perturbation factors, P Q . The method used has the advantage that many important parameters can be extracted as a function of depth instead of determination at only the reference depth as has typically been done. Results obtained here are in good agreement with measured and other calculated results. The photon-electron conversion factors obtained for a Farmer-type NE2571 and plane-parallel PTW Roos, IBA NACP-02 and Exradin A11 chambers are 0.903, 0.896, 0.894 and 0.906, respectively. These typically differ by less than 0.7% from the contentious TG-51 values but have much smaller systematic uncertainties. These results are valuable for reference dosimetry of high-energy electron beams. © 2012 American Association of Physicists in Medicine.

  2. Active tuning of high-Q dielectric metasurfaces

    DOE PAGES

    Parry, Matthew; Komar, Andrei; Hopkins, Ben; ...

    2017-08-02

    Here, we demonstrate the active tuning of all-dielectric metasurfaces exhibiting high-quality factor (high-Q) resonances. The active control is provided by embedding the asymmetric silicon meta-atoms with liquid crystals, which allows the relative index of refraction to be controlled through heating. It is found that high quality factor resonances (Q = 270 ± 30) can be tuned over more than three resonance widths. Our results demonstrate the feasibility of using all-dielectric metasurfaces to construct tunable narrow-band filters.

  3. Imaging contrast and tip-sample interaction of non-contact amplitude modulation atomic force microscopy with Q-control

    NASA Astrophysics Data System (ADS)

    Shi, Shuai; Guo, Dan; Luo, Jianbin

    2017-10-01

    Active quality factor (Q) exhibits many promising properties in dynamic atomic force microscopy. Energy dissipation and image contrasts are investigated in the non-contact amplitude modulation atomic force microscopy (AM-AFM) with an active Q-control circuit in the ambient air environment. Dissipated power and virial were calculated to compare the highly nonlinear interaction of tip-sample and image contrasts with different Q gain values. Greater free amplitudes and lower effective Q values show better contrasts for the same setpoint ratio. Active quality factor also can be employed to change tip-sample interaction force in non-contact regime. It is meaningful that non-destructive and better contrast images can be realized in non-contact AM-AFM by applying an active Q-control to the dynamic system.

  4. Maternal diet quality before pregnancy and risk of childhood leukaemia.

    PubMed

    Singer, Amanda W; Carmichael, Suzan L; Selvin, Steve; Fu, Cecilia; Block, Gladys; Metayer, Catherine

    2016-10-01

    Previous studies on maternal nutrition and childhood leukaemia risk have focused on the role of specific nutrients such as folate and have not considered broader measures of diet quality, which may better capture intake of diverse nutrients known to impact fetal development. We examined the relationship between maternal diet quality before pregnancy, as summarised by a diet quality index, and risk of childhood acute lymphoblastic leukaemia (ALL) and acute myeloid leukaemia (AML) in a case-control study in California. Dietary intake in the year before pregnancy was assessed using FFQ in 681 ALL cases, 103 AML cases and 1076 matched controls. Conditional logistic regression was used to estimate OR and 95 % CI for diet quality continuous score and quartiles (Q1-Q4). Higher maternal diet quality score was associated with reduced risk of ALL (OR 0·66; 95 % CI 0·47, 0·93 for Q4 v. Q1) and possibly AML (OR 0·42; 95 % CI 0·15, 1·15 for Q4 v. Q1). No single index component appeared to account for the association. The association of maternal diet quality with risk of ALL was stronger in children diagnosed under the age of 5 years and in children of women who did not report using vitamin supplements before pregnancy. These findings suggest that the joint effects of many dietary components may be important in influencing childhood leukaemia risk.

  5. Measuring patients' satisfaction with their anti-TNF treatment in severe Crohn's disease: scoring and psychometric validation of the Satisfaction for PAtients in Crohn's diseasE Questionnaire (SPACE-Q(©)).

    PubMed

    Gilet, Hélène; Arnould, Benoit; Fofana, Fatoumata; Clerson, Pierre; Colombel, Jean-Frédéric; D'Hondt, Olivier; Faure, Patrick; Hagège, Hervé; Nachury, Maria; Nahon, Stéphane; Tucat, Gilbert; Vandromme, Luc; Cazala-Telinge, Ines; Thibout, Emmanuel

    2014-01-01

    Severe Crohn's disease management includes anti-tumor necrosis factor (anti-TNF) drugs that differ from early-stage treatments regarding efficacy, safety, and convenience. This study aimed to finalize and psychometrically validate the Satisfaction for PAtients in Crohn's diseasE Questionnaire (SPACE-Q(©)), developed to measure satisfaction with anti-TNF treatment in patients with severe Crohn's disease. A total of 279 patients with severe Crohn's disease receiving anti-TNF therapy completed the SPACE-Q 62-item pilot version at inclusion and 12 and 13 weeks after first anti-TNF injection. The final SPACE-Q scoring was defined using multitrait and regression analyses and clinical relevance considerations. Psychometric validation included clinical validity against Harvey-Bradshaw score, concurrent validity against Treatment Satisfaction Questionnaire for Medication (TSQM), internal consistency reliability, test-retest reliability, and responsiveness against the patient global impression of change (PGIC). Quality of completion was good (55%-67% of patients completed all items). Four items were removed from the questionnaire. Eleven scores were defined within the final 58-item SPACE-Q: disease control; symptoms, anal symptoms, and quality of life transition scales; tolerability; convenience; expectation confirmation toward efficacy, side effects, and convenience; satisfaction with treatment; and motivation. Scores met standards for concurrent validity (correlation between SPACE-Q satisfaction with treatment and TSQM satisfaction scores =0.59), internal consistency reliability (Cronbach's α=0.67-0.93), test-retest reliability (intraclass correlations =0.62-0.91), and responsiveness (improvement in treatment experience assessed by the SPACE-Q for patients reporting improvement on the PGIC). Significantly different mean scores were observed between groups of patients with different Harvey-Bradshaw disease severity scores. The SPACE-Q is a valid, reliable, and responsive instrument to measure satisfaction with anti-TNF treatment in patients with severe Crohn's disease and for use in future studies.

  6. Real-time water quality monitoring at a Great Lakes National Park

    USGS Publications Warehouse

    Byappanahalli, Muruleedhara; Nevers, Meredith; Shively, Dawn; Spoljaric, Ashley; Otto, Christopher

    2018-01-01

    Quantitative polymerase chain reaction (qPCR) was used by the USEPA to establish new recreational water quality criteria in 2012 using the indicator bacteria enterococci. The application of this method has been limited, but resource managers are interested in more timely monitoring results. In this study, we evaluated the efficacy of qPCR as a rapid, alternative method to the time-consuming membrane filtration (MF) method for monitoring water at select beaches and rivers of Sleeping Bear Dunes National Lakeshore in Empire, MI. Water samples were collected from four locations (Esch Road Beach, Otter Creek, Platte Point Bay, and Platte River outlet) in 2014 and analyzed for culture-based (MF) and non-culture-based (i.e., qPCR) endpoints using Escherichia coli and enterococci bacteria. The MF and qPCR enterococci results were significantly, positively correlated overall (r = 0.686, p < 0.0001, n = 98) and at individual locations as well, except at the Platte River outlet location: Esch Road Beach (r = 0.441, p = 0.031, n = 24), Otter Creek (r = 0.592, p = 0.002, n = 24), and Platte Point Bay (r = 0.571, p = 0.004, n = 24). Similarly, E. coli MF and qPCR results were significantly, positively correlated (r = 0.469, p < 0.0001, n = 95), overall but not at individual locations. Water quality standard exceedances based on enterococci levels by qPCR were lower than by MF method: 3 and 16, respectively. Based on our findings, we conclude that qPCR may be a viable alternative to the culture-based method for monitoring water quality on public lands. Rapid, same-day results are achievable by the qPCR method, which greatly improves protection of the public from water-related illnesses.

  7. Research on Seismic Wave Attenuation in Gas Hydrates Layer Using Vertical Cable Seismic Data

    NASA Astrophysics Data System (ADS)

    Wang, Xiangchun; Liang, Lunhang; Wu, Zhongliang

    2018-06-01

    Vertical cable seismic (VCS) data are the most suitable seismic data for estimating the quality factor Q values of layers under the sea bottom by now. Here the quality factor Q values are estimated using the high-precision logarithmic spectrum ratio method for VCS data. The estimated Q values are applied to identify the layers with gas hydrates and free gas. From the results it can be seen that the Q value in layer with gas hydrates becomes larger and the Q value in layer with free gas becomes smaller than layers without gas hydrates or free gas. Additionally, the estimated Q values are used for inverse Q filtering processing to compensate the attenuated seismic signal's high-frequency component. From the results it can be seen that the main frequency of seismic signal is improved and the frequency band is broadened, the resolution of the VCS data is improved effectively.

  8. Fabrication of a microresonator-fiber assembly maintaining a high-quality factor by CO₂ laser welding.

    PubMed

    Fang, Zhiwei; Lin, Jintian; Wang, Min; Liu, Zhengming; Yao, Jinping; Qiao, Lingling; Cheng, Ya

    2015-10-19

    We demonstrate fabrication of a microtoroid resonator of a high-quality (high-Q) factor using femtosecond laser three-dimensional (3D) micromachining. A fiber taper is reliably assembled to the microtoroid using CO2 laser welding. Specifically, we achieve a high-Q-factor of 2.12 × 10(6) in the microresonator-fiber assembly by optimizing the contact position between the fiber taper and the microtoroid.

  9. The Negative Correlation between Fiber Color and Quality Traits Revealed by QTL Analysis.

    PubMed

    Feng, Hongjie; Guo, Lixue; Wang, Gaskin; Sun, Junling; Pan, Zhaoe; He, Shoupu; Zhu, Heqin; Sun, Jie; Du, Xiongming

    2015-01-01

    Naturally existing colored cotton was far from perfection due to having genetic factors for lower yield, poor fiber quality and monotonous color. These factors posed a challenge to colored cotton breeding and innovation. To identify novel quantitative trait loci (QTL) for fiber color along with understanding of correlation between fiber color and quality in colored cotton, a RIL and two F2 populations were generated from crosses among Zong128 (Brown fiber cotton) and two white fiber cotton lines which were then analyzed in four environments. Two stable and major QTLs (qLC-7-1, qFC-7-1) for fiber lint and fuzz color were detected accounting for 16.01%-59.85% of the phenotypic variation across multiple generations and environments. Meanwhile, some minor QTLs were also identified on chromosomes 5, 14, 21 and 24 providing low phenotypic variation (<5%) from only F2 populations, not from the RILs population. Especially, a multiple-effect locus for fiber color and quality has been detected between flanking markers NAU1043 and NAU3654 on chromosome 7 (A genome) over multiple environments. Of which, qLC-7-1, qFC-7-1 were responsible for positive effects and improved fiber color in offsprings. Meanwhile, the QTLs (qFL-7-1, qFU-7-1, qFF-7-1, qFE-7-1, and qFS-7-1) for fiber quality had negative effects and explained 2.19%-8.78% of the phenotypic variation. This multiple-effect locus for fiber color and quality may reveal the negative correlation between the two types of above traits, so paving the way towards cotton genetic improvement.

  10. RF-MEMS Load Sensors with Enhanced Q-factor and Sensitivity in a Suspended Architecture.

    PubMed

    Melik, Rohat; Unal, Emre; Perkgoz, Nihan Kosku; Puttlitz, Christian; Demir, Hilmi Volkan

    2011-03-01

    In this paper, we present and demonstrate RF-MEMS load sensors designed and fabricated in a suspended architecture that increases their quality-factor (Q-factor), accompanied with an increased resonance frequency shift under load. The suspended architecture is obtained by removing silicon under the sensor. We compare two sensors that consist of 195 μm × 195 μm resonators, where all of the resonator features are of equal dimensions, but one's substrate is partially removed (suspended architecture) and the other's is not (planar architecture). The single suspended device has a resonance of 15.18 GHz with 102.06 Q-factor whereas the single planar device has the resonance at 15.01 GHz and an associated Q-factor of 93.81. For the single planar device, we measured a resonance frequency shift of 430 MHz with 3920 N of applied load, while we achieved a 780 MHz frequency shift in the single suspended device. In the planar triplet configuration (with three devices placed side by side on the same chip, with the two outmost ones serving as the receiver and the transmitter), we observed a 220 MHz frequency shift with 3920 N of applied load while we obtained a 340 MHz frequency shift in the suspended triplet device with 3920 N load applied. Thus, the single planar device exhibited a sensitivity level of 0.1097 MHz/N while the single suspended device led to an improved sensitivity of 0.1990 MHz/N. Similarly, with the planar triplet device having a sensitivity of 0.0561 MHz/N, the suspended triplet device yielded an enhanced sensitivity of 0.0867 MHz/N.

  11. A high-quality factor of 267 000 micromechanical silicon resonator utilizing TED-free torsional vibration mode

    NASA Astrophysics Data System (ADS)

    Nakamura, K.; Naito, Y.; Onishi, K.; Kawakatsu, H.

    2012-12-01

    In industrial applications of a micromechanical silicon resonator as a physical sensor, a high-quality factor Q and a low-temperature coefficient of Q (TCQ) are required for high sensitivity in a wide temperature range. Although the newly developed thin film encapsulation technique enables a beam to operate with low viscous damping in a vacuum cavity, the Q of a flexural vibration mode is limited by thermo-elastic damping (TED). We proposed a torsional beam resonator which features both a high Q and a low TCQ because theoretically the torsional vibration mode does not suffer from TED. From experiments, Q of 267 000 and TCQ of 1.4 for the 20 MHz torsional vibration mode were observed which were superior to those of the flexural mode. The pressure of the residual gas in the cavity of only 20 pl volume, which is one of the energy loss factors limiting the Q, was successfully estimated to be 1-14 Pa. Finally, the possibilities of improving the Q and the difference of the measured TCQ from a theoretical value were discussed.

  12. High beam quality of a Q-switched 2-µm Tm,Ho:LuVO4 laser

    NASA Astrophysics Data System (ADS)

    Wang, Wei; Yang, Xining; Shen, Yingjie; Li, Linjun; Zhou, Long; Yang, Yuqiang; Bai, Yunfeng; Xie, Wenqiang; Ye, Guangchao; Yu, Xiaoyang

    2018-05-01

    A diode-end-pumped 2.05-µm Q-switched Tm,Ho:LuVO4 laser is reported in this paper. The cryogenic Tm3+ (5.0 at.%),Ho3+ (0.5 at.%):LuVO4 crystal was pumped by an 800-nm laser diode. At a pulse repetition frequency of 10 kHz, the maximum average output power of 3.77 W was achieved at 77 K when an incident pump power of 14.7 W was used. The slope efficiency and optical-optical conversion efficiency were 28.3 and 25.6%, respectively. The maximum per pulse energy was 2.54 mJ for a pulse duration of 69.9 ns. The beam quality factor Mx 2 was approximately 1.17 and My 2 was approximately 1.01 for the Tm,Ho:LuVO4 laser.

  13. Improving the Optical Quality Factor of the WGM Resonator

    NASA Technical Reports Server (NTRS)

    Savchenkov, Anatoliy; Matsko, Andrey; Iltchenko, Vladimir

    2008-01-01

    Resonators usually are characterized with two partially dependent values: finesse (F) and quality factor (Q). The finesse of an empty Fabry-Perot (FP) resonator is defined solely by the quality of its mirrors and is calculated as F=piR(exp 1/2)/(1-R). The maximum up-to-date value of reflectivity R approximately equal to 1 - 1.6 x 10(exp -6) is achieved with dielectric mirrors. An FP resonator made with the mirrors has finesse F=1.9 x 10(exp 6). Further practical increase of the finesse of FP resonators is problematic because of the absorption and the scattering of light in the mirror material through fundamental limit on the reflection losses given by the internal material losses and by thermodynamic density fluctuations on the order of parts in 109. The quality factor of a resonator depends on both its finesse and its geometrical size. A one-dimensional FP resonator has Q=2 F L/lambda, where L is the distance between the mirrors and lambda is the wavelength. It is easy to see that the quality factor of the resonator is unlimited because L is unlimited. F and Q are equally important. In some cases, finesse is technically more valuable than the quality factor. For instance, buildup of the optical power inside the resonator, as well as the Purcell factor, is proportional to finesse. Sometimes, however, the quality factor is more valuable. For example, inverse threshold power of intracavity hyperparametric oscillation is proportional to Q(exp 2) and efficiency of parametric frequency mixing is proportional to Q(exp 3). Therefore, it is important to know both the maximally achievable finesse and quality factor values of a resonator. Whispering gallery mode (WGM) resonators are capable of achieving larger finesse compared to FP resonators. For instance, fused silica resonators with finesse 2.3 x 10(exp 6) and 2.8 x 10(exp 6) have been demonstrated. Crystalline WGM resonators reveal even larger finesse values, F=6.3 x 10(exp 6), because of low attenuation of light in the transparent optical crystals. The larger values of F and Q result in the enhancement of various nonlinear processes. Low-threshold Raman lasing, optomechanical oscillations, frequency doubling, and hyperparametric oscillations based on these resonators have been recently demonstrated. Theory predicts a possibility of nearly 10(exp 14) room-temperature optical Q-factors of optical crystalline WGM resonators, which correspond to finesse levels higher than 10(exp 9). Experiments have shown numbers a thousand times lower than that. The difference occurs due to media imperfections. To substantially reduce the optical losses caused by the imperfections, a specific, multi-step, asymptotic processing of the resonator is implemented. The technique has been initially developed to reduce microwave absorption in dielectric resonators. One step of the process consists of mechanical polishing performed after high temperature annealing. Several steps repeat one after another to lead to significant reduction in optical attenuation and, as a result, to the increase of Q-factor as well as finesse of the resonator which demonstrates a CaF2 WGM resonator with F greater than 10(exp 7) and Q greater than 10(exp 11).

  14. Polyunsaturated fats, carbohydrates and carotid disease: The Atherosclerosis Risk in Communities (ARIC) Carotid MRI study

    PubMed Central

    Dearborn, Jennifer L.; Qiao, Ye; Guallar, Eliseo; Steffen, Lyn M.; Gottesman, Rebecca F.; Zhang, Yiyi; Wasserman, Bruce A.

    2016-01-01

    Background and aims Carbohydrates and fat intake have both been linked to development of atherosclerosis. We examined associations between glycemic index GI and fat intake with carotid atherosclerosis. Methods The Atherosclerosis Risk in Communities (ARIC) cohort enrolled participants during the period 1987–1989 and the Carotid MRI sub-study occurred between 2004 and 2006 (1,672 participants attending both visits). Measures of carbohydrate quality (usual GI), fat intake (total, polyunsaturated and saturated) and overall dietary quality index (DASH Diet Score) were derived from a 66-item food frequency questionnaire administered at baseline. Trained readers measured lipid core presence and maximum wall thickness. Using multivariate logistic regression, we determined the odds of lipid core presence by quintile (Q) of energy-adjusted dietary components. Restricted cubic spline models were used to examine non-linear associations between dietary components and maximum wall thickness. Results Mean daily polyunsaturated fat intake was 5 g (SD 1.4). GI and polyunsaturated fat intake had a nonlinear relationship with maximum wall thickness. Low (1–4 g) and high (6–12 g) polyunsaturated fat intake were associated with a statistically significant decreased odds of lipid core presence compared to intake in a majority of participants (OR Q5 vs. Q2–4: 0.64, 95% CI 0.42 to 0.98; OR Q1 vs. Q2–4: 0.64, 95% CI 0.42, 0.96), however, the association with lipid core was attenuated by adjustment for maximum wall thickness, hypertension, hyperlipidemia, and diabetes. Conclusions GI and polyunsaturated fat intake were not associated with high-risk plaque features, such as lipid core presence, independent of traditional vascular risk factors. PMID:27234460

  15. Polyunsaturated fats, carbohydrates and carotid disease: The Atherosclerosis Risk in Communities (ARIC) Carotid MRI study.

    PubMed

    Dearborn, Jennifer L; Qiao, Ye; Guallar, Eliseo; Steffen, Lyn M; Gottesman, Rebecca F; Zhang, Yiyi; Wasserman, Bruce A

    2016-08-01

    Carbohydrates and fat intake have both been linked to development of atherosclerosis. We examined associations between glycemic index (GI) and fat intake with carotid atherosclerosis. The Atherosclerosis Risk in Communities (ARIC) cohort enrolled participants during the period 1987-1989 and the Carotid MRI sub-study occurred between 2004 and 2006 (1672 participants attending both visits). Measures of carbohydrate quality (usual GI), fat intake (total, polyunsaturated and saturated) and overall dietary quality index (DASH Diet Score) were derived from a 66-item food frequency questionnaire administered at baseline. Trained readers measured lipid core presence and maximum wall thickness. Using multivariate logistic regression, we determined the odds of lipid core presence by quintile (Q) of energy-adjusted dietary components. Restricted cubic spline models were used to examine non-linear associations between dietary components and maximum wall thickness. Mean daily polyunsaturated fat intake was 5 g (SD 1.4). GI and polyunsaturated fat intake had a nonlinear relationship with maximum wall thickness. Low (1-4 g) and high (6-12 g) polyunsaturated fat intake were associated with a statistically significant decreased odds of lipid core presence compared to intake in a majority of participants (OR Q5 vs. Q2-4: 0.64, 95% CI 0.42 to 0.98; OR Q1 vs. Q2-4: 0.64, 95% CI 0.42, 0.96), however, the association with lipid core was attenuated by adjustment for maximum wall thickness, hypertension, hyperlipidemia, and diabetes. GI and polyunsaturated fat intake were not associated with high-risk plaque features, such as lipid core presence, independent of traditional vascular risk factors. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  16. Randomized, controlled trial of dextromethorphan/quinidine for pseudobulbar affect in multiple sclerosis.

    PubMed

    Panitch, Hillel S; Thisted, Ronald A; Smith, Richard A; Wynn, Daniel R; Wymer, James P; Achiron, Anat; Vollmer, Timothy L; Mandler, Raul N; Dietrich, Dennis W; Fletcher, Malcolm; Pope, Laura E; Berg, James E; Miller, Ariel

    2006-05-01

    To evaluate the efficacy and safety of DM/Q (capsules containing dextromethorphan [DM] and quinidine [Q]) compared with placebo, taken twice daily, for the treatment of pseudobulbar affect over a 12-week period in multiple sclerosis patients. A total of 150 patients were randomized in a double-blind, placebo-controlled study to assess pseudobulbar affect with the validated Center for Neurologic Study-Lability Scale. Each patient also recorded the number of episodes experienced between visits, estimated quality of life and quality of relationships on visual analog scales, and completed a pain rating scale. Patients receiving DM/Q had greater reductions in Center for Neurologic Study-Lability Scale scores than those receiving placebo (p < 0.0001) at all clinic visits (days 15, 29, 57, and 85). All secondary end points also favored DM/Q, including the number of crying or laughing episodes (p

  17. SU-E-T-146: Reference Dosimetry for Protons and Light-Ion Beams Based on Graphite Calorimetry.

    PubMed

    Rossomme, S; Palmans, H; Thomas, R; Lee, N; Bailey, M; Shipley, D; Al-Sulaiti, L; Cirrone, P; Romano, F; Kacperek, A; Bertrand, D; Vynckier, S

    2012-06-01

    The IAEA TRS-398 code of practice can be applied for the measurement of absorbed dose to water under reference conditions with an ionization chamber. For protons, the combined relative standard uncertainty on those measurements is less than 2% while for light-ion beams, it is considerably larger, i.e. 3.2%, mainly due to the higher uncertainty contributions for the water to air stopping power ration and the W air-value on the beam quality correction factors kQ,Q 0 . To decrease this uncertainty, a quantification of kQ,Q 0 is proposed using a primary standard level graphite calorimeter. This work includes numerical and experimental determinations of dose conversion factors to derive dose to water from graphite calorimetry. It also reports on the first experimental data obtained with the graphite calorimeter in proton, alpha and carbon ion beams. Firstly, the dose conversion has been calculated with by Geant4 Monte-Carlo simulations through the determination of the water to graphite stopping power ratio and the fluence correction factor. The latter factor was also derived by comparison of measured ionization curves in graphite and water. Secondly, kQ,Q 0 was obtained by comparison of the dose response of ionization chambers with that of the calorimeter. Stopping power ratios are found to vary by no more than 0.35% up to the Bragg peak, while fluence correction factors are shown to increase slightly above unity close to the Bragg peak. The comparison of the calorimeter with ionization chambers is currently under analysis. For the modulated proton beam, preliminary results on W air confirm the value recommended in TRS-398. Data in both the non-modulated proton and light-ion beams indicate higher values but further investigation of heat loss corrections is needed. The application of graphite calorimetry to proton, alpha and carbon ion beams has been demonstrated successfully. Other experimental campaigns will be held in 2012. This work is supported by the BioWin program of the Wallon Government. © 2012 American Association of Physicists in Medicine.

  18. New set of design rules for resonant refractive index sensors enabled by FFT based processing of the measurement data.

    PubMed

    Gounaridis, Lefteris; Groumas, Panos; Schreuder, Erik; Heideman, Rene; Avramopoulos, Hercules; Kouloumentas, Christos

    2016-04-04

    It is still a common belief that ultra-high quality-factors (Q-factors) are a prerequisite in optical resonant cavities for high refractive index resolution and low detection limit in biosensing applications. In combination with the ultra-short steps that are necessary when the measurement of the resonance shift relies on the wavelength scanning of a laser source and conventional methods for data processing, the high Q-factor requirement makes these biosensors extremely impractical. In this work we analyze an alternative processing method based on the fast-Fourier transform, and show through Monte-Carlo simulations that improvement by 2-3 orders of magnitude can be achieved in the resolution and the detection limit of the system in the presence of amplitude and spectral noise. More significantly, this improvement is maximum for low Q-factors around 104 and is present also for high intra-cavity losses and large scanning steps making the designs compatible with the low-cost aspect of lab-on-a-chip technology. Using a micro-ring resonator as model cavity and a system design with low Q-factor (104), low amplitude transmission (0.85) and relatively large scanning step (0.25 pm), we show that resolution close to 0.01 pm and detection limit close to 10-7 RIU can be achieved improving the sensing performance by more than 2 orders of magnitude compared to the performance of systems relying on a simple peak search processing method. The improvement in the limit of detection is present even when the simple method is combined with ultra-high Q-factors and ultra-short scanning steps due to the trade-off between the system resolution and sensitivity. Early experimental results are in agreement with the trends of the numerical studies.

  19. Oral Health Related Quality of Life among Tamil Speaking Adults Attending a Dental Institution in Chennai, Southern India

    PubMed Central

    Tadepalli, Anupama; Victor, Dhayanand John; Dharuman, Smriti

    2016-01-01

    Introduction Oral Health-Related Quality of Life (OHRQoL) indicates an individual’s perception of how their well-being and quality of life is influenced by oral health. It facilitates treatment planning, assessing patient centred treatment outcomes and satisfaction. Aim The study aimed to identify the factors influencing OHRQoL among Tamil speaking South Indian adult population. Materials and Methods Non-probability sampling was done and 199 subjects aged 20-70 years were recruited for this observational study. The subjects were requested to fill a survey form along with the validated Tamil General Oral Health Assessment Index (GOHAI-Tml) questionnaire in the waiting area following which clinical examination was done by a single experienced Periodontist. Results The mean score with standard deviation for physical dimension was 4.34±0.96, psychological dimension was 4.03±1.13 and pain was 4.05±1.09 on GOHAI. Greater impacts were seen for psychosocial dimensions like pleased with the appearance of teeth/denture Q7 (3.7±1.2), worried about the problems with teeth/denture Q9 (3.7±1) and pain or discomfort in teeth Q12 (3.8±1). Functions like swallowing Q3 (4.5±0.8) and speaking Q4 (4.6±0.7) were minimally affected. As age increased subjects perceived more negative impacts as indicated by lower ADD-GOHAI and higher SC-GOHAI scores (p<0.01). Subjects complaining of bad breath, bleeding gums and Temporomandibular Joint (TMJ) problems, reported poor OHRQoL (p<0.05). It was observed that as self-perceived oral and general health status deteriorated, OHRQoL also worsened (p<0.01). Subjects with missing teeth, cervical abrasion, restorations, gingival recession and mobility had more impacts on OHRQoL (p<0.05). Subjects diagnosed with periodontitis had lower OHRQoL as reported on the scale than gingivitis subjects (p<0.01). Conclusion In this study minimal impact was seen in all the three dimensions assessed with GOHAI. Factors like age, education, employment status, income, self-reported oral health, self-perceived general health, satisfaction with oral health, perceived need for treatment and denture wearing status influenced perceived OHRQoL. Bad breath, bleeding gums, TMJ problems, more number of missing teeth, decayed teeth, cervical abrasion, gingival recession and mobility were associated with poor OHRQoL. PMID:27891472

  20. The effects of three factor VII polymorphisms on factor VII coagulant levels in healthy Singaporean Chinese, Malay and Indian newborns.

    PubMed

    Quek, S C; Low, P S; Saha, N; Heng, C K

    2006-11-01

    Factor VII (FVII) is an independent risk factor for coronary artery disease. Three polymorphisms of the factor VII gene (F7) were studied in a group of healthy newborns comprising 561 Chinese, 398 Malays and 226 Asian Indians from Singapore. The allele frequencies of 3 polymorphisms (R353Q, Promoter 0/10bp Del/Ins and Intron 7) in the FVII gene were ascertained through genotyping by polymerase chain reaction and restriction digestion of amplified fragments. In Chinese the minor allele frequencies are Q: 0.04, Ins: 0.03, R7: 0.44; Malays, Q: 0.06, Ins: 0.10, R7: 0.41; and Indians, Q: 0.25, Ins: 0.23, R7: 0.43. Strong linkage disequilibrium (Delta > 0.7) is observed between the 0/10 bp and the R353Q sites in all ethnic groups. We conclude that: (i) the prevalence of the minor Q and Ins alleles of the R353Q and 0/10 bp polymorphisms are significantly higher in the Indian newborns than the Chinese and Malays; (ii) the Q allele is significantly associated (p = 0.01) with a lower plasma FVII coagulant level in the Indian and Malay neonates; and this polymorphism explains up to 3.8% of the variance in FVII coagulant levels; (iii) there is no significant difference in allele frequencies of the three polymorphisms between neonates with and without family histories of CAD.

  1. Electrical investigations of hybrid OLED microcavity structures with novel encapsulation methods

    NASA Astrophysics Data System (ADS)

    Meister, Stefan; Brückner, Robert; Fröb, Hartmut; Leo, Karl

    2016-04-01

    An electrical driven organic solid state laser is a very challenging goal which is so far well beyond reach. As a step towards realization, we monolithically implemented an Organic Light Emitting Diode (OLED) into a dielectric, high quality microcavity (MC) consisting of two Distributed Bragg Reectors (DBR). In order to account for an optimal optical operation, the OLED structure has to be adapted. Furthermore, we aim to excite the device not only electrically but optically as well. Different OLED structures with an emission layer consisting of Alq3:DCM (2 wt%) were investigated. The External Quantum Efficiencies (EQE) of this hybrid structures are in the range of 1-2 %, as expected for this material combination. Including metal layers into a MC is complicated and has a huge impact on the device performance. Using Transfer-Matrix-Algorithm (TMA) simulations, the best positions for the metal electrodes are determined. First, the electroluminescence (EL) of the adjusted OLED structure on top of a DBR is measured under nitrogen atmosphere. The modes showed quality factors of Q = 60. After the deposition of the top DBR, the EL is measured again and the quality factors increased up to Q = 600. Considering the two 25-nm-thick-silver contacts a Q-factor of 600 is very high. The realization of a suitable encapsulation method is important. Two approaches were successfully tested. The first method is based on the substitution of a DBR layer with a layer produced via Atomic Layer Deposition (ALD). The second method uses a 0.15-mm-thick cover glass glued on top of the DBR with a 0.23-μm-thick single-component glue layer. Due to the working encapsulation, it is possible to investigate the sample under ambient conditions.

  2. Study of the in-medium nucleon electromagnetic form factors using a light-front nucleon wave function combined with the quark-meson coupling model

    NASA Astrophysics Data System (ADS)

    de Araújo, W. R. B.; de Melo, J. P. B. C.; Tsushima, K.

    2018-02-01

    We study the nucleon electromagnetic (EM) form factors in symmetric nuclear matter as well as in vacuum within a light-front approach using the in-medium inputs calculated by the quark-meson coupling model. The same in-medium quark properties are used as those used for the study of in-medium pion properties. The zero of the proton EM form factor ratio in vacuum, the electric to magnetic form factor ratio μpGEp (Q2) /GMp (Q2) (Q2 = -q2 > 0 with q being the four-momentum transfer), is determined including the latest experimental data by implementing a hard constituent quark component in the nucleon wave function. A reasonable fit is achieved for the ratio μpGEp (Q2) /GMp (Q2) in vacuum, and we predict that the Q02 value to cross the zero of the ratio to be about 15 GeV2. In addition the double ratio data of the proton EM form factors in 4He and H nuclei, [GEp4He (Q2) /G4HeMp (Q2) ] / [GEp1H (Q2) /GMp1H (Q2) ], extracted by the polarized (e → ,e‧ p →) scattering experiment on 4He at JLab, are well described. We also predict that the Q02 value satisfying μpGEp (Q02) /GMp (Q0 2) = 0 in symmetric nuclear matter, shifts to a smaller value as increasing nuclear matter density, which reflects the facts that the faster falloff of GEp (Q2) as increasing Q2 and the increase of the proton mean-square charge radius. Furthermore, we calculate the neutron EM form factor double ratio in symmetric nuclear matter for 0.1

  3. [Psychometric properties of Q-DIO, an instrument to measure the quality of documented nursing diagnoses, interventions and outcomes].

    PubMed

    Müller-Staub, Maria; Lunney, Margaret; Lavin, Mary Ann; Needham, Ian; Odenbreit, Matthias; van Achterberg, Theo

    2010-04-01

    The instrument Q-DIO was developed in the years 2005 till 2006 to measure the quality of documented nursing diagnoses, interventions, and nursing sensitive patient outcomes. Testing psychometric properties of the Q-DIO (Quality of nursing Diagnoses, Interventions and Outcomes.) was the study aim. Instrument testing included internal consistency, test-retest reliability, interrater reliability, item analyses, and an assessment of the objectivity. To render variation in scores, a random strata sample of 60 nursing documentations was drawn. The strata represented 30 nursing documentations with and 30 without application of theory based, standardised nursing language. Internal consistency of the subscale nursing diagnoses as process showed Cronbach's Alpha 0.83 [0.78, 0.88]; nursing diagnoses as product 0.98 [0.94, 0.99]; nursing interventions 0.90 [0.85, 0.94]; and nursing-sensitive patient outcomes 0.99 [0.95, 0.99]. With Cohen's Kappa of 0.95, the intrarater reliability was good. The interrater reliability showed a Kappa of 0.94 [0.90, 0.96]. Item analyses confirmed the fulfilment of criteria for degree of difficulty and discriminative validity of the items. In this study, Q-DIO has shown to be a reliable instrument. It allows measuring the documented quality of nursing diagnoses, interventions and outcomes with and without implementation of theory based, standardised nursing languages. Studies for further testing of Q-DIO in other settings are recommended. The results implicitly support the use of nursing classifications such as NANDA, NIC and NOC.

  4. Empirical evaluation of humpback whale telomere length estimates; quality control and factors causing variability in the singleplex and multiplex qPCR methods.

    PubMed

    Olsen, Morten Tange; Bérubé, Martine; Robbins, Jooke; Palsbøll, Per J

    2012-09-06

    Telomeres, the protective cap of chromosomes, have emerged as powerful markers of biological age and life history in model and non-model species. The qPCR method for telomere length estimation is one of the most common methods for telomere length estimation, but has received recent critique for being too error-prone and yielding unreliable results. This critique coincides with an increasing awareness of the potentials and limitations of the qPCR technique in general and the proposal of a general set of guidelines (MIQE) for standardization of experimental, analytical, and reporting steps of qPCR. In order to evaluate the utility of the qPCR method for telomere length estimation in non-model species, we carried out four different qPCR assays directed at humpback whale telomeres, and subsequently performed a rigorous quality control to evaluate the performance of each assay. Performance differed substantially among assays and only one assay was found useful for telomere length estimation in humpback whales. The most notable factors causing these inter-assay differences were primer design and choice of using singleplex or multiplex assays. Inferred amplification efficiencies differed by up to 40% depending on assay and quantification method, however this variation only affected telomere length estimates in the worst performing assays. Our results suggest that seemingly well performing qPCR assays may contain biases that will only be detected by extensive quality control. Moreover, we show that the qPCR method for telomere length estimation can be highly precise and accurate, and thus suitable for telomere measurement in non-model species, if effort is devoted to optimization at all experimental and analytical steps. We conclude by highlighting a set of quality controls which may serve for further standardization of the qPCR method for telomere length estimation, and discuss some of the factors that may cause variation in qPCR experiments.

  5. Empirical evaluation of humpback whale telomere length estimates; quality control and factors causing variability in the singleplex and multiplex qPCR methods

    PubMed Central

    2012-01-01

    Background Telomeres, the protective cap of chromosomes, have emerged as powerful markers of biological age and life history in model and non-model species. The qPCR method for telomere length estimation is one of the most common methods for telomere length estimation, but has received recent critique for being too error-prone and yielding unreliable results. This critique coincides with an increasing awareness of the potentials and limitations of the qPCR technique in general and the proposal of a general set of guidelines (MIQE) for standardization of experimental, analytical, and reporting steps of qPCR. In order to evaluate the utility of the qPCR method for telomere length estimation in non-model species, we carried out four different qPCR assays directed at humpback whale telomeres, and subsequently performed a rigorous quality control to evaluate the performance of each assay. Results Performance differed substantially among assays and only one assay was found useful for telomere length estimation in humpback whales. The most notable factors causing these inter-assay differences were primer design and choice of using singleplex or multiplex assays. Inferred amplification efficiencies differed by up to 40% depending on assay and quantification method, however this variation only affected telomere length estimates in the worst performing assays. Conclusion Our results suggest that seemingly well performing qPCR assays may contain biases that will only be detected by extensive quality control. Moreover, we show that the qPCR method for telomere length estimation can be highly precise and accurate, and thus suitable for telomere measurement in non-model species, if effort is devoted to optimization at all experimental and analytical steps. We conclude by highlighting a set of quality controls which may serve for further standardization of the qPCR method for telomere length estimation, and discuss some of the factors that may cause variation in qPCR experiments. PMID:22954451

  6. High-Q microwave photonic filter with a tuned modulator.

    PubMed

    Capmany, J; Mora, J; Ortega, B; Pastor, D

    2005-09-01

    We propose the use of tuned electro-optic or electroabsorption external modulators to implement high-quality (high-Q) factor, single-bandpass photonic filters for microwave signals. Using this approach, we experimentally demonstrate a transversal finite impulse response with a Q factor of 237. This is to our knowledge the highest value ever reported for a passive finite impulse-response microwave photonic filter.

  7. ProQ3D: improved model quality assessments using deep learning.

    PubMed

    Uziela, Karolis; Menéndez Hurtado, David; Shu, Nanjiang; Wallner, Björn; Elofsson, Arne

    2017-05-15

    Protein quality assessment is a long-standing problem in bioinformatics. For more than a decade we have developed state-of-art predictors by carefully selecting and optimising inputs to a machine learning method. The correlation has increased from 0.60 in ProQ to 0.81 in ProQ2 and 0.85 in ProQ3 mainly by adding a large set of carefully tuned descriptions of a protein. Here, we show that a substantial improvement can be obtained using exactly the same inputs as in ProQ2 or ProQ3 but replacing the support vector machine by a deep neural network. This improves the Pearson correlation to 0.90 (0.85 using ProQ2 input features). ProQ3D is freely available both as a webserver and a stand-alone program at http://proq3.bioinfo.se/. arne@bioinfo.se. Supplementary data are available at Bioinformatics online. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  8. Knudsen pump produced via silicon deep RIE, thermal oxidation, and anodic bonding processes for on-chip vacuum pumping

    NASA Astrophysics Data System (ADS)

    Van Toan, Nguyen; Inomata, Naoki; Trung, Nguyen Huu; Ono, Takahito

    2018-05-01

    This work describes the fabrication and evaluation of the Knudsen pump for on-chip vacuum pumping that works based on the principle of a thermal transpiration. Three AFM (atomic force microscope) cantilevers are integrated into small chambers with a size of 5 mm  ×  3 mm  ×  0.4 mm for the pump’s evaluation. Knudsen pump is fabricated using deep RIE (reactive ion etching), wet thermal oxidation and anodic bonding processes. The fabricated device is evaluated by monitoring the quality (Q) factor of the integrated cantilevers. The Q factor of the cantilever is increased from 300 -1150 in cases without and with a temperature difference approximately 25 °C between the top (the hot side at 40 °C) and bottom (the cold side at 15 °C) sides of the fabricated device, respectively. The evacuated chamber pressure of around 10 kPa is estimated from the Q factor of the integrated cantilevers.

  9. Morphology-dependent resonances of a microsphere-optical fiber system

    NASA Astrophysics Data System (ADS)

    Griffel, Giora; Arnold, Stephen; Taskent, Dogan; Serpengüzel, Ali; Connolly, John; Morris, Nancy

    1996-05-01

    Morphology-dependent resonances of microspheres sitting upon an index-matched single-mode fiber half-coupler are excited by a tunable 753-nm distributed-feedback laser. Resonance peaks in the scattering spectra and associated dips in the transmission spectra for the TE and TM modes are observed. We present a new model that describes this interaction in terms of the fiber-sphere coupling coefficient and the microsphere's intrinsic quality factor Q0 . This model enables us to obtain expressions for the finesse and the Q factor of the composite particle-fiber system, the resonance width, and the depth of the dips measured in the transmission spectra. Our model shows that index matching improves the coupling efficiency by more than a factor of 2 compared with that of a non-index-matched system.

  10. Morphology-dependent resonances of a microsphere-optical fiber system.

    PubMed

    Griffel, G; Arnold, S; Taskent, D; Serpengüzel, A; Connolly, J; Morris, N

    1996-05-15

    Morphology-dependent resonances of microspheres sitting upon an index-matched single-mode fiber half-coupler are excited by a tunable 753-nm distributed-feedback laser. Resonance peaks in the scattering spectra and associated dips in the transmission spectra for the TE and TM modes are observed. We present a new model that describes this interaction in terms of the fiber-sphere coupling coefficient and the microsphere's intrinsic quality factor Q(0). This model enables us to obtain expressions for the finesse and the Q factor of the composite particle-fiber system, the resonance width, and the depth of the dips measured in the transmission spectra. Our model shows that index matching improves the coupling efficiency by more than a factor of 2 compared with that of a non-index-matched system.

  11. Optimal sensitivity for molecular recognition MAC-mode AFM

    PubMed

    Schindler; Badt; Hinterdorfer; Kienberger; Raab; Wielert-Badt; Pastushenko

    2000-02-01

    Molecular recognition force microscopy (MRFM) using the magnetic AC mode (MAC mode) atomic force microscope (AFM) was recently investigated to locate and probe recognition sites. A flexible crosslinker carrying a ligand is bound to the tip for the molecular recognition of receptors on the surface of a sample. In this report, the driving frequency is calculated which optimizes the sensitivity (S). The sensitivity of MRFM is defined as the relative change of the magnetically excited cantilever deflection amplitude arising from a crosslinker/antibody/antigen connection that is characterized by a very small force constant. The sensitivity is calculated in a damped oscillator model with a certain value of quality factor Q, which, together with load, defines the frequency response (unloaded oscillator shows resonance at Q > 0.707). If Q < 1, the greatest value of S corresponds to zero driving frequency omega (measured in units of eigenfrequency). Therefore, for Q < 1, MAC-mode has no advantage in comparison with DC-mode. Two additional extremes are found at omegaL = (1 - 1/Q)(1/2) and omegaR = (1 + 1/Q)(1/2), with corresponding sensitivities S(L) = Q2/(2Q - 1), S(R) = Q2/(2Q + 1). The L-extreme exists only for Q > 1, and then S(L) > S(R), i.e. the L-extreme is the main one. For Q > 1, S(L) > 1, and for Q > 2.41, S(R) > 1. These are the critical Q-values, above which selecting driving frequency equal to sigmaL or sigmaR brings advantage to MAC mode vs. DC mode. Satisfactory quality of the oscillator model is demonstrated by comparison of some results with those calculated within the classical description of cantilevers.

  12. High-Q photonic resonators and electro-optic coupling using silicon-on-lithium-niobate

    NASA Astrophysics Data System (ADS)

    Witmer, Jeremy D.; Valery, Joseph A.; Arrangoiz-Arriola, Patricio; Sarabalis, Christopher J.; Hill, Jeff T.; Safavi-Naeini, Amir H.

    2017-04-01

    Future quantum networks, in which superconducting quantum processors are connected via optical links, will require microwave-to-optical photon converters that preserve entanglement. A doubly-resonant electro-optic modulator (EOM) is a promising platform to realize this conversion. Here, we present our progress towards building such a modulator by demonstrating the optically-resonant half of the device. We demonstrate high quality (Q) factor ring, disk and photonic crystal resonators using a hybrid silicon-on-lithium-niobate material system. Optical Q factors up to 730,000 are achieved, corresponding to propagation loss of 0.8 dB/cm. We also use the electro-optic effect to modulate the resonance frequency of a photonic crystal cavity, achieving a electro-optic modulation coefficient between 1 and 2 pm/V. In addition to quantum technology, we expect that our results will be useful both in traditional silicon photonics applications and in high-sensitivity acousto-optic devices.

  13. General expressions for the coupling coefficient, quality and filling factors for a cavity with an insert using energy coupled mode theory.

    PubMed

    Elnaggar, Sameh Y; Tervo, Richard; Mattar, Saba M

    2014-05-01

    A cavity (CV) with a dielectric resonator (DR) insert forms an excellent probe for the use in electron paramagnetic resonance (EPR) spectrometers. The probe's coupling coefficient, κ, the quality factor, Q, and the filling factor, η are vital in assessing the EPR spectrometer's performance. Coupled mode theory (CMT) is used to derive general expressions for these parameters. For large permittivity the dominating factor in κ is the ratio of the DR and CV cross sectional areas rather than the dielectric constant. Thus in some cases, resonators with low dielectric constant can couple much stronger with the cavity than do resonators with a high dielectric constant. When the DR and CV frequencies are degenerate, the coupled η is the average of the two uncoupled ones. In practical EPR probes the coupled η is approximately half of that of the DR. The Q of the coupled system generally depends on the eigenvectors, uncoupled frequencies (ω1,ω2) and the individual quality factors (Q1,Q2). It is calculated for different probe configurations and found to agree with the corresponding HFSS® simulations. Provided there is a large difference between the Q1, Q2 pair and the frequencies of DR and CV are degenerate, Q is approximately equal to double the minimum of Q1 and Q2. In general, the signal enhancement ratio, Iwithinsert/Iempty, is obtained from Q and η. For low loss DRs it only depends on η1/η2. However, when the DR has a low Q, the uncoupled Qs are also needed. In EPR spectroscopy it is desirable to excite only a single mode. The separation between the modes, Φ, is calculated as a function of κ and Q. It is found to be significantly greater than five times the average bandwidth. Thus for practical probes, it is possible to excite one of the coupled modes without exciting the other. The CMT expressions derived in this article are quite general and are in excellent agreement with the lumped circuit approach and finite numerical simulations. Hence they can also be applied to a loop-gap resonator in a cavity. For the design effective EPR probes, one needs to consider the κ, Q and η parameters. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. General expressions for the coupling coefficient, quality and filling factors for a cavity with an insert using energy coupled mode theory

    NASA Astrophysics Data System (ADS)

    Elnaggar, Sameh Y.; Tervo, Richard; Mattar, Saba M.

    2014-05-01

    A cavity (CV) with a dielectric resonator (DR) insert forms an excellent probe for the use in electron paramagnetic resonance (EPR) spectrometers. The probe’s coupling coefficient, κ, the quality factor, Q, and the filling factor, η are vital in assessing the EPR spectrometer’s performance. Coupled mode theory (CMT) is used to derive general expressions for these parameters. For large permittivity the dominating factor in κ is the ratio of the DR and CV cross sectional areas rather than the dielectric constant. Thus in some cases, resonators with low dielectric constant can couple much stronger with the cavity than do resonators with a high dielectric constant. When the DR and CV frequencies are degenerate, the coupled η is the average of the two uncoupled ones. In practical EPR probes the coupled η is approximately half of that of the DR. The Q of the coupled system generally depends on the eigenvectors, uncoupled frequencies (ω1, ω2) and the individual quality factors (Q1, Q2). It is calculated for different probe configurations and found to agree with the corresponding HFSS® simulations. Provided there is a large difference between the Q1, Q2 pair and the frequencies of DR and CV are degenerate, Q is approximately equal to double the minimum of Q1 and Q2. In general, the signal enhancement ratio, I/Iempty, is obtained from Q and η. For low loss DRs it only depends on η1/η2. However, when the DR has a low Q, the uncoupled Qs are also needed. In EPR spectroscopy it is desirable to excite only a single mode. The separation between the modes, Φ, is calculated as a function of κ and Q. It is found to be significantly greater than five times the average bandwidth. Thus for practical probes, it is possible to excite one of the coupled modes without exciting the other. The CMT expressions derived in this article are quite general and are in excellent agreement with the lumped circuit approach and finite numerical simulations. Hence they can also be applied to a loop-gap resonator in a cavity. For the design effective EPR probes, one needs to consider the κ, Q and η parameters.

  15. The resonant body transistor.

    PubMed

    Weinstein, Dana; Bhave, Sunil A

    2010-04-14

    This paper introduces the resonant body transistor (RBT), a silicon-based dielectrically transduced nanoelectromechanical (NEM) resonator embedding a sense transistor directly into the resonator body. Combining the benefits of FET sensing with the frequency scaling capabilities and high quality factors (Q) of internal dielectrically transduced bar resonators, the resonant body transistor achieves >10 GHz frequencies and can be integrated into a standard CMOS process for on-chip clock generation, high-Q microwave circuits, fundamental quantum-state preparation and observation, and high-sensitivity measurements. An 11.7 GHz bulk-mode RBT is demonstrated with a quality factor Q of 1830, marking the highest frequency acoustic resonance measured to date on a silicon wafer.

  16. High field Q slope and the effect of low-temperature baking at 3 GHz

    NASA Astrophysics Data System (ADS)

    Ciovati, G.; Eremeev, G.; Hannon, F.

    2018-01-01

    A strong degradation of the unloaded quality factor with field, called high field Q slope, is commonly observed above Bp ≅100 mT in elliptical superconducting niobium cavities at 1.3 and 1.5 GHz. In the present experiments several 3 GHz niobium cavities were measured up to and above Bp ≅100 mT . The measurements show that a high field Q slope phenomenon limits the field reach at this frequency, that the high field Q slope onset field depends weakly on the frequency, and that the high field Q slope can be removed by the typical empirical solution of electropolishing followed by heating to 120°C for 48 hrs. In addition, one of the cavities reached a quench field of 174 mT and its field dependence of the quality factor was compared against global heating predicted by a thermal feedback model.

  17. On the tunability of quality-factor for optical Tamm plasmon modes

    NASA Astrophysics Data System (ADS)

    Kumar, Samir; Das, Ritwick

    2017-09-01

    We present a comprehensive investigation to ascertain the impact of gold and silver films on modifying the quality-factor (Q-factor) of optical Tamm-plasmon (OTP) resonance in a metal-distributed Bragg reflector (M-DBR) geometry. Here, OTP mode is excited using direct incidence of white-light-source at normal incidence as well as oblique incidence on M-DBR geometry. The lifetime of OTP in gold and silver deposited films on DBR mirror was determined from OTP resonance linewidth. The lifetime and the Q-factor of OTP modes are found to depend on DBR bilayers, metal film thickness as well as on different plasmon active metals. This finding would facilitate tuning the Q-factor and consequently, the lifetime of OTP modes for various applications in all-optical switches and modulators. In addition, we discuss the spectral characteristics of OTP modes excited using normal and oblique incident of source.

  18. Factor Structure of the Schalock and Keith Quality of Life Questionnaire (QOL-Q): Validation on Mexican and Spanish Samples

    ERIC Educational Resources Information Center

    Caballo, C.; Crespo, M.; Jenaro, C.; Verdugo, M. A.; Martinez, J. L.

    2005-01-01

    Background: The Quality of Life Questionnaire (QOL-Q) is used widely to evaluate the quality of life of persons with intellectual disability (ID). Its validity for use with Spanish-speaking cultures has been demonstrated for individuals with visual disabilities, but not for those with physical or intellectual disabilities. Such was the purpose of…

  19. The best interest of the child-questionnaire, reliability and validity: preliminary data on the question 'where to live after detention or secure treatment?'.

    PubMed

    Kalverboer, Margrite; Ten Brummelaar, Mijntje; Post, Wendy; Zijlstra, Elianne; Harder, Annemiek; Knorth, Erik

    2012-02-01

    The Best Interest of the Child-Questionnaire (BIC-Q) has been designed as an instrument for screening the quality of the rearing situation of children with behavioural problems or delinquency. It is intended to aid legal decisions in juvenile and family law. The aim of the study was to establish the reliability and validation of the BIC-Q. Records of 83 children in detention or secure treatment centres and 58 children with no delinquent behaviours were rated by trained researchers. Interrater reliability was tested with a sub-sample of 31 of the former. Content validity was evaluated across the whole group, using Cronbach's alpha to check internal consistency, Spearman's rho to examine correlations and explorative principal component analysis (PCA) to test the extent to which variance in the 14 underlying conditions could be accounted for by a single factor 'quality of rearing'. Interrater reliability was good (r = 0.89). The PCA lent support to the content validity of the questionnaire with four factors, which together explained 66% of the variance in child rearing: (1) attachment and bonding; (2) rules and provisions; (3) health care and physical care in the family context; and (4) care and models provided for in the societal environment. The BIC-Q is a reliable and valid measure of the overall quality of child rearing. Preliminary results indicate that the BIC-Q may be applied to support court decisions on where the child should live after detention or secure treatment. Copyright © 2011 John Wiley & Sons, Ltd.

  20. Measuring visual outcomes in children with uveitis using the “Effects of Youngsters’ Eyesight on Quality of Life” questionnaire

    PubMed Central

    Angeles-Han, Sheila T.; Yeh, Steven; McCracken, Courtney; Jenkins, Kirsten; Stryker, Daneka; Myoung, Erica; Vogler, Larry; Rouster-Stevens, Kelly; Lambert, Scott R.; Harrison, Melanie J.; Prahalad, Sampath; Drews-Botsch, Carolyn

    2015-01-01

    Objective The Effects of Youngsters’ Eyesight on Quality of Life (EYE-Q) is a novel measure of vision-related quality of life (QOL) and function in children. We aim to determine the validity of EYE-Q in childhood uveitis. Methods We abstracted medical record data on arthritis and uveitis in a convenience sample of children with juvenile idiopathic arthritis (JIA) and/or uveitis. In addition to the EYE-Q, parents and patients completed questionnaires on overall QOL (Pediatric QOL Inventory - PedsQL), and physical functioning (Childhood Health Assessment Questionnaire - CHAQ). Results Among 57 children (8 JIA, 24 JIA and uveitis, 25 uveitis alone), 102 ocular examinations were performed within 1 month of completing questionnaires. Uveitis patients had bilateral disease (69%), anterior involvement (78%), synechiae (51%) and cataracts (49%). Children with vision loss in their better eye (visual acuity (VA) 20/50 or worse) had worse EYE-Q (p = 0.006), and PedsQL (p = 0.028), but not CHAQ scores. The EYE-Q moderately correlated with logMAR VA (rs = −0.43), PedsQL (rs = 0.43) and CHAQ (rs = −0.45), but was not correlated with anterior chamber cells or intraocular pressure. The PedsQL and CHAQ did not correlate with VA or cells. There were strong correlations between the parent and child EYE-Q (rs = 0.62). Cronbach's α for the child report was 0.91. The EYE-Q had strong test-retest reliability (rs=0.75). Conclusion The EYE-Q may be an important tool in the assessment of visual outcomes in childhood uveitis and an improvement over general measures in detecting changes in vision-related function. PMID:26037544

  1. The association between socioeconomic factors and breast cancer-specific survival varies by race.

    PubMed

    Agarwal, Shailesh; Ying, Jian; Boucher, Kenneth M; Agarwal, Jayant P

    2017-01-01

    Although racial disparity is well described for oncologic outcomes, factors associated with survival within racial groups remains unexplored. The objective of this study is to determine whether breast cancer survival among White or Black patients is associated with differing patient factors. Women diagnosed with breast cancer from 1998 through 2012 were identified in the Surveillance, Epidemiology, and End Results (SEER) database. Cox proportional hazard logistic regression was used to estimate cause-specific survival in the combined cohort, and separate cohorts of Black or White patients only. Main outcomes included cause-specific survival in cohorts of Black only, White only, or all patients adjusted for demographic and oncologic factors. A total of 406,907 Black (10.8%) or White (89.2%) patients diagnosed with breast cancer from 1998 through 2012 were isolated. Cancer-specific survival analysis of the combined cohort showed significantly decreased hazard ratio (H.R.) in patients from the higher economic quartiles (Q1: 1.0 (ref), Q2: 0.95 (p<0.01), Q3: 0.94 (p<0.01), Q4: 0.87 (p<0.001)). Analysis of the White only cohort showed a similar relationship with income (Q1: 1.0 (ref), Q2: 0.95 (p<0.01), Q3: 0.95 (p<0.01), Q4: 0.86 (p<0.001)). However, analysis of the Black only cohort did not show a relationship with income (Q1: 1.0 (ref), Q2: 1.04 (p = 0.34), Q3: 0.97 (p = 0.53), Q4: 1.04 (p = 0.47)). A test of interaction confirmed that the association between income and cancer-specific survival is dependent on patient race, both with and without adjustment for demographic and oncologic characteristics (p<0.01). While median county income is positively associated with cancer-specific survival among White patients, this is not the case with Black patients. Similar findings were noted for education level. These findings suggest that the association between socioeconomic status and breast cancer survival commonly reported in the literature is specific to White patients. These findings provide insight into differences between White and Black patients in cancer-specific survival.

  2. Effects of nutraceutical diet integration, with coenzyme Q10 (Q-Ter multicomposite) and creatine, on dyspnea, exercise tolerance, and quality of life in COPD patients with chronic respiratory failure

    PubMed Central

    2013-01-01

    Background The protein-calorie malnutrition, resulting in muscle mass loss, frequently occurs in severe COPD patients with chronic respiratory failure (CRF), causing dyspnea, reduced exercise tolerance and impaired quality of life. The cause of this occurrence is an intake-output energy imbalance. A documented deficit of phosphocreatine and reduced mithocondrial energy production can contribute to this imbalance. Aim of this study is to verify whether a dietary supplementation with creatine and coenzyme Q10, important mitochondrial function factors, is able to influence this mechanism leading to a dyspnea reduction and improving exercise tolerance and quality of life. Methods 55 COPD patients with chronic respiratory failure (in long term O2 therapy), in stable phase of the disease and without severe comorbidities were assigned (double-blind, randomized) to: group A (30 patients) with daily dietary supplementation with Creatine 340 mg + 320 mg Coenzyme Q-Ter (Eufortyn®, Scharper Therapeutics Srl) for 2 months whereas Group B (25 patients) received placebo. All patients continued the same diet, rehabilitation and therapy during the study. At recruitment (T0) and after 2 months (T1), patients were submitted to medical history, anthropometry (BMI), bioelectrical impedance, arterial blood gas analysis, evaluation of dyspnea (VAS, Borg, BDI, MRC) and functional independence (ADL), 6-minute walk test (6MWT) and quality of life questionnaire (SGRQ). At 6 months and 1 year, a telephone follow up was conducted on exacerbations number. Results No significant difference was detected at baseline (T0) in the 2 groups. After 2 months of therapy (T1) the FFMI increased in the daily dietary supplementation group (+ 3.7 %) and decreased in the placebo group (- 0.6 %), resulting in a statistically significant (p < 0.001) treatment difference. Statistically significant treatment differences, favouring daily dietary supplementation group, were also seen for the 6MWT comparison. Group A patients also showed significant: 1) improvement in the degree of dyspnea (VAS: p < 0.05; Borg: p < 0.05; MRC: p < 0.001; BDI1: p < 0.05; BDI3: p < 0.03), and independence level in activities of daily living (p < 0.03); 2) improvement in quality of life in activity section (- 6.63 pt) and in total score (- 5.43 pt); 3) exacerbation number decrease (p < 0.02). No significant differences were found (end of study vs baseline) in group B. Conclusions The nutraceutical diet integration with Q-Ter and creatine, in COPD patients with CRF in O2TLT induced an increasing lean body mass and exercise tolerance, reducing dyspnea, quality of life and exacerbations. These results provide a first demonstration that acting on protein synthesis and muscular efficiency can significantly modify the systemic consequences of the disease. PMID:23800154

  3. Quality of life is significantly associated with survival in women with advanced epithelial ovarian cancer: An ancillary data analysis of the NRG Oncology/Gynecologic Oncology Group (GOG-0218) study.

    PubMed

    Phippen, N T; Secord, A A; Wolf, S; Samsa, G; Davidson, B; Abernethy, A P; Cella, D; Havrilesky, L J; Burger, R A; Monk, B J; Leath, C A

    2017-10-01

    Evaluate association between baseline quality of life (QOL) and changes in QOL measured by FACT-O TOI with progression-free disease (PFS) and overall survival (OS) in advanced epithelial ovarian cancer (EOC). Patients enrolled in GOG-0218 with completed FACT-O TOI assessments at baseline and at least one follow-up assessment were eligible. Baseline FACT-O TOI scores were sorted by quartiles (Q1-4) and outcomes compared between Q1 and Q2-4 with log-rank statistic and multivariate Cox regression adjusting for age, stage, post-surgical residual disease size, and performance status (PS). Trends in FACT-O TOI scores from baseline to the latest follow-up assessment were evaluated for impact on intragroup (Q1 or Q2-4) outcome by log-rank analysis. Of 1152 eligible patients, 283 formed Q1 and 869 formed Q2-4. Mean baseline FACT-O TOI scores were 47.5 for Q1 vs. 74.7 for Q2-4 (P<0.001). Q1 compared to Q2-4 had worse median OS (37.5 vs. 45.6months, P=0.001) and worse median PFS (12.5 vs. 13.1months, P=0.096). Q2-4 patients had decreased risks of disease progression (HR 0.974, 95% CI 0.953-0.995, P=0.018), and death (HR 0.963, 95% CI 0.939-0.987, P=0.003) for each five-point increase in baseline FACT-O TOI. Improving versus worsening trends in FACT-O TOI scores were associated with longer median PFS (Q1: 12.7 vs. 8.6months, P=0.001; Q2-4: 16.7 vs. 11.1months, P<0.001) and median OS (Q1: 40.8 vs. 16months, P<0.001; Q2-4: 54.4 vs. 33.6months, P<0.001). Baseline FACT-O TOI scores were independently prognostic of PFS and OS while improving compared to worsening QOL was associated with significantly better PFS and OS in women with EOC. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Improved model quality assessment using ProQ2.

    PubMed

    Ray, Arjun; Lindahl, Erik; Wallner, Björn

    2012-09-10

    Employing methods to assess the quality of modeled protein structures is now standard practice in bioinformatics. In a broad sense, the techniques can be divided into methods relying on consensus prediction on the one hand, and single-model methods on the other. Consensus methods frequently perform very well when there is a clear consensus, but this is not always the case. In particular, they frequently fail in selecting the best possible model in the hard cases (lacking consensus) or in the easy cases where models are very similar. In contrast, single-model methods do not suffer from these drawbacks and could potentially be applied on any protein of interest to assess quality or as a scoring function for sampling-based refinement. Here, we present a new single-model method, ProQ2, based on ideas from its predecessor, ProQ. ProQ2 is a model quality assessment algorithm that uses support vector machines to predict local as well as global quality of protein models. Improved performance is obtained by combining previously used features with updated structural and predicted features. The most important contribution can be attributed to the use of profile weighting of the residue specific features and the use features averaged over the whole model even though the prediction is still local. ProQ2 is significantly better than its predecessors at detecting high quality models, improving the sum of Z-scores for the selected first-ranked models by 20% and 32% compared to the second-best single-model method in CASP8 and CASP9, respectively. The absolute quality assessment of the models at both local and global level is also improved. The Pearson's correlation between the correct and local predicted score is improved from 0.59 to 0.70 on CASP8 and from 0.62 to 0.68 on CASP9; for global score to the correct GDT_TS from 0.75 to 0.80 and from 0.77 to 0.80 again compared to the second-best single methods in CASP8 and CASP9, respectively. ProQ2 is available at http://proq2.wallnerlab.org.

  5. Significance of chick quality score in broiler production.

    PubMed

    van de Ven, L J F; van Wagenberg, A V; Uitdehaag, K A; Groot Koerkamp, P W G; Kemp, B; van den Brand, H

    2012-10-01

    The quality of day old chicks is crucial for profitable broiler production, but a difficult trait to define. In research, both qualitative and quantitative measures are used with variable predictive value for subsequent performance. In hatchery practice, chick quality is judged on a binomial scale, as chicks are divided into first grade (Q1-saleable) and second grade (Q2) chicks right after hatch. Incidences and reasons for classifying chicks as Q2, and potential of these chicks for survival and post-hatch performance have hardly been investigated, but may provide information for flock performance. We conducted an experiment to investigate (1) the quality of a broiler flock and the relation with post-hatch flock performance based on a qualitative score (Pasgar©score) of Q1 chicks and based on the incidence of Q2 chicks and (2) the reasons for classifying chicks as Q2, and the potential of these chicks for survival and post-hatch growth. The performance was followed of Q1 and Q2 chicks obtained from two breeder flocks that hatched in two different hatching systems (a traditional hatcher or a combined hatching and brooding system, named Patio). Eggs were incubated until embryo day 18, when they were transferred to one of the two hatching systems. At embryo day 21/post-hatch day 0, all chicks from the hatcher (including Q2 chicks) were brought to Patio, where the hatchery manager marked the Q2 chicks from both flocks and hatching systems and registered apparent reasons for classifying these chicks as Q2. Chick quality was assessed of 100 Q1 chicks from each flock and hatching system. Weights of all chicks were determined at days 0, 7, 21 and 42. There were no correlations between mean Pasgar©score and post-hatch growth or mortality, and suboptimal navel quality was the only quality trait associated with lower post-hatch growth. Growth was clearly affected by breeder flock and hatching system, which could not be linked to mean Pasgar©score or incidence of Q2 chicks. Q2 chicks showed lower post-hatch growth compared to Q1 chicks but effects on flock performance at slaughter weight were limited because early mortality in Q2 chicks was high (62.50% at 7 days). We concluded that chick qualitative scores and the incidence of Q2 chicks may be informative for the quality of incubation, but are not predictive for post-hatch flock performance. Culling Q2 chicks after hatch is well-founded in terms of both animal welfare and profitability.

  6. Development and validation testing of a short nutrition questionnaire to identify dietary risk factors in preschoolers aged 12–36 months

    PubMed Central

    Rice, Niamh; Gibbons, Helena; McNulty, Breige A.; Walton, Janette; Flynn, Albert; Gibney, Michael J.; Nugent, Anne P.

    2015-01-01

    Background Although imbalances in dietary intakes can have short and longer term influences on the health of preschool children, few tools exist to quickly and easily identify nutritional risk in otherwise healthy young children. Objectives To develop and test the validity of a parent-administered questionnaire (NutricheQ) as a means of evaluating dietary risk in young children (12–36 months). Design Following a comprehensive development process and internal reliability assessment, the NutricheQ questionnaire was validated in a cohort of 371 Irish preschool children as part of the National Preschool Nutrition Survey. Dietary risk was rated on a scale ranging from 0 to 22 from 11 questions, with a higher score indicating higher risk. Results Children with higher NutricheQ scores had significantly (p<0.05) lower mean daily intakes of key nutrients such as iron, zinc, vitamin D, riboflavin, niacin, folate, phosphorous, potassium, carotene, retinol, and dietary fibre. They also had lower (p<0.05) intakes of vegetables, fish and fish dishes, meat and infant/toddler milks and higher intakes of processed foods and non-milk beverages, confectionery, sugars and savoury snack foods indicative of poorer dietary quality. Areas under the curve values of 84.7 and 75.6% were achieved for ‘medium’ and ‘high’ dietary risk when compared with expert risk ratings indicating good consistency between the two methods. Conclusion NutricheQ is a valid method of quickly assessing dietary quality in preschoolers and in identifying those at increased nutritional risk. In Context Analysis of data from national food and nutrition surveys typically identifies shortfalls in dietary intakes or quality of young children. This can relate to intakes of micronutrients such as iron or vitamin D as well as to the balance of macronutrients they consume (e.g. fat or sugar). Alongside this lie concerns regarding overweight and obesity and physical inactivity. This combination of risk factors has potential negative effects for both short and longer term health. Hence, screening tools, such as NutricheQ described here, offer an opportunity for early identification and subsequent appropriate timely intervention from 12 months of age. This paper describes the development and validation of NutricheQ, a short user-friendly questionnaire. Designed to be administered by parents or carers, it aims to help healthcare professionals identify children at risk based on known, evidence-based nutritional risk factors. It is hoped in the longer term that this tool can be adapted for use globally and improve child health through early identification, which can be followed up by targeted, cost-effective interventions. PMID:26058751

  7. Biosensing Using Microring Resonator Interferograms

    PubMed Central

    Hsu, Shih-Hsiang; Yang, Yung-Chia; Su, Yu-Hou; Wang, Sheng-Min; Huang, Shih-An; Lin, Ching-Yu

    2014-01-01

    Optical low-coherence interferometry (OLCI) takes advantage of the variation in refractive index in silicon-wire microring resonator (MRR) effective lengths to perform glucose biosensing using MRR interferograms. The MRR quality factor (Q), proportional to the effective length, could be improved using the silicon-wire propagation loss and coupling ratio from the MRR coupler. Our study showed that multimode interference (MMI) performed well in broad band response, but the splitting ratio drifted to 75/25 due to the stress issue. The glucose sensing sensitivity demonstrated 0.00279 meter per refractive-index-unit (RIU) with a Q factor of ∼30,000 under transverse electric polarization. The 1,310 nm DFB laser was built in the OLCI system as the optical ruler achieving 655 nm characterization accuracy. The lowest sensing limitation was therefore 2 × 10−4 RIU. Moreover, the MRR effective length from the glucose sensitivity could be utilized to experimentally demonstrate the silicon wire effective refractive index with a width of 0.45 μm and height of 0.26 μm. PMID:24434876

  8. Internal friction quality-factor Q under confining pressure. [of lunar rocks

    NASA Technical Reports Server (NTRS)

    Tittmann, B. R.; Ahlberg, L.; Nadler, H.; Curnow, J.; Smith, T.; Cohen, E. R.

    1977-01-01

    It has been found in previous studies that small amounts of adsorbed volatiles can have a profound effect on the internal friction quality-factor Q of rocks and other porous media. Pandit and Tozer (1970) have suggested that the laboratory-measured Q of volatile-free rocks should be similar to the in situ seismic Q values of near-surface lunar rocks which according to Latham et al. (1970) are in the range of 3000-5000. Observations of dramatic increases in Q with outgassing up to values approaching 2000 in the seismic frequency range confirm this supposition. Measurements under confining pressures with the sample encapsulated under hard vacuum are reported to aid in the interpretation of seismic data obtained below the lunar surface. It has been possible to achieve in the experiments Q values just under 2000 at about 1 kbar for a terrestrial analog of lunar basalt. It was found that a well-outgassed sample maintains a high Q whereas one exposed to moisture maintains a low Q as the confining pressure is raised to 2.5 kbar. This result suggests that volatiles can indeed affect Q when cracks are partially closed and the high lunar seismic Q values reported are concomitant with very dry rock down to depths of at least 50 km.

  9. All-dielectric metasurface analogue of electromagnetically induced transparency [High Quality Factor Fano-Resonant All-Dielectric Metamaterials

    DOE PAGES

    Yang, Yuanmu; Kravchenko, Ivan I.; Briggs, Dayrl P.; ...

    2014-12-16

    Fano-resonant plasmonic metamaterials and nanostructures have become a major focus of the nanophotonics fields over the past several years due their ability to produce high quality factor (Q-factor) resonances. The origin of such resonances is the interference between a broad and narrow resonance, ultimately allowing suppression of radiative damping. However, Fano-resonant plasmonic structures still suffer non-radiative damping due to Ohmic loss, ultimately limiting the achievable Q-factors to values less than ~10. Here, we report experimental demonstration of Fano-resonant silicon-based metamaterials that have a response that mimics the electromagnetically induced transparency (EIT) found in atomic systems. Due to extremely low absorptionmore » loss, a record-high quality factor (Q-factor) of 306 was experimentally observed. Furthermore, the unit cell of the metamaterial was designed with a feed-gap which results in strong local field enhancement in the surrounding medium resulting in strong light-matter interaction. This allows the metamaterial to serve as a refractive index sensor with a figure-of-merit (FOM) of 101, far exceeding the performance of previously demonstrated localized surface plasmon resonance sensors.« less

  10. A Steel Ball Surface Quality Inspection Method Based on a Circumferential Eddy Current Array Sensor.

    PubMed

    Zhang, Huayu; Xie, Fengqin; Cao, Maoyong; Zhong, Mingming

    2017-07-01

    To efficiently inspect surface defects on steel ball bearings, a new method based on a circumferential eddy current array (CECA) sensor was proposed here. The best probe configuration, in terms of the coil quality factor (Q-factor), magnetic field intensity, and induced eddy current density on the surface of a sample steel ball, was determined using 3-, 4-, 5-, and 6-coil probes, for analysis and comparison. The optimal lift-off from the measured steel ball, the number of probe coils, and the frequency of excitation current suitable for steel ball inspection were obtained. Using the resulting CECA sensor to inspect 46,126 steel balls showed a miss rate of ~0.02%. The sensor was inspected for surface defects as small as 0.05 mm in width and 0.1 mm in depth.

  11. Quality factor of luminescent solar concentrators and practical concentration limits attainable with semiconductor quantum dots

    DOE PAGES

    Klimov, Victor I.; Baker, Thomas A.; Lim, Jaehoon; ...

    2016-05-09

    In this study, luminescent solar concentrators (LSCs) can be utilized as both large-area collectors of solar radiation supplementing traditional photovoltaic cells as well as semitransparent “solar windows” that provide a desired degree of shading and simultaneously serve as power-generation units. An important characteristic of an LSC is a concentration factor (C) that can be thought of as a coefficient of effective enlargement (or contraction) of the area of a solar cell when it is coupled to the LSC. Here we use analytical and numerical Monte Carlo modeling in addition to experimental studies of quantum-dot-based LSCs to analyze the factors thatmore » influence optical concentration in practical devices. Our theoretical model indicates that the maximum value of C achievable with a given fluorophore is directly linked to the LSC quality factor (Q LSC) defined as the ratio of absorption coefficients at the wavelengths of incident and reemitted light. In fact, we demonstrate that the ultimate concentration limit (C 0) realized in large-area devices scales linearly with the LSC quality factor and in the case of perfect emitters and devices without back reflectors is approximately equal to Q LSC. To test the predictions of this model, we conduct experimental studies of LSCs based on visible-light emitting II–VI core/shell quantum dots with two distinct LSC quality factors. We also investigate devices based on near-infrared emitting CuInSe xS 2–x quantum dots for which the large emission bandwidth allows us to assess the impact of varied Q LSC on the concentration factor by simply varying the detection wavelength. In all cases, we find an excellent agreement between the model and the experimental observations, suggesting that the developed formalism can be utilized for express evaluation of prospective LSC performance based on the optical spectra of LSC fluorophores, which should facilitate future efforts on the development of high-performance devices based on quantum dots as well as other types of emitters.« less

  12. Quality factor of luminescent solar concentrators and practical concentration limits attainable with semiconductor quantum dots

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klimov, Victor I.; Baker, Thomas A.; Lim, Jaehoon

    In this study, luminescent solar concentrators (LSCs) can be utilized as both large-area collectors of solar radiation supplementing traditional photovoltaic cells as well as semitransparent “solar windows” that provide a desired degree of shading and simultaneously serve as power-generation units. An important characteristic of an LSC is a concentration factor (C) that can be thought of as a coefficient of effective enlargement (or contraction) of the area of a solar cell when it is coupled to the LSC. Here we use analytical and numerical Monte Carlo modeling in addition to experimental studies of quantum-dot-based LSCs to analyze the factors thatmore » influence optical concentration in practical devices. Our theoretical model indicates that the maximum value of C achievable with a given fluorophore is directly linked to the LSC quality factor (Q LSC) defined as the ratio of absorption coefficients at the wavelengths of incident and reemitted light. In fact, we demonstrate that the ultimate concentration limit (C 0) realized in large-area devices scales linearly with the LSC quality factor and in the case of perfect emitters and devices without back reflectors is approximately equal to Q LSC. To test the predictions of this model, we conduct experimental studies of LSCs based on visible-light emitting II–VI core/shell quantum dots with two distinct LSC quality factors. We also investigate devices based on near-infrared emitting CuInSe xS 2–x quantum dots for which the large emission bandwidth allows us to assess the impact of varied Q LSC on the concentration factor by simply varying the detection wavelength. In all cases, we find an excellent agreement between the model and the experimental observations, suggesting that the developed formalism can be utilized for express evaluation of prospective LSC performance based on the optical spectra of LSC fluorophores, which should facilitate future efforts on the development of high-performance devices based on quantum dots as well as other types of emitters.« less

  13. Heritability of first-order-lateral roots in five Quercus species: effect on 1-0 seedling quality evaluation

    Treesearch

    Paul P. Kormanik; Shi-Jean S. Sung; Taryn L. Kormanik; Stanley J. Zarnoch; Scott Schlarbaum

    1997-01-01

    Heritability estimates (h2) were calculated for first-order lateral root (FOLR) numbers on a family plot mean basis for 5 Quercus species: Q. alba, Q. falcata, Q, michauxii, Q. pagoda, and Q. rubra. All species were grown with the...

  14. Ultra-high quality factors in superconducting niobium cavities in ambient magnetic fields up to 190 mG

    DOE PAGES

    Romanenko, A.; Grassellino, A.; Crawford, A. C.; ...

    2014-12-10

    Ambient magnetic field, if trapped in the penetration depth, leads to the residual resistance and therefore sets the limit for the achievable quality factors in superconducting niobium resonators for particle accelerators. Here, we show that a complete expulsion of the magnetic flux can be performed and leads to: (1) record quality factors Q > 2 x 10¹¹ up to accelerating gradient of 22 MV/m; (2) Q ~ 3 x 10¹⁰ at 2 K and 16 MV/m in up to 190 mG magnetic fields. This is achieved by large thermal gradients at the normal/superconducting phase front during the cooldown. Our findingsmore » open up a way to ultra-high quality factors at low temperatures and show an alternative to the sophisticated magnetic shielding implemented in modern superconducting accelerators.« less

  15. Superconducting RF R&D | Technical Division

    Science.gov Websites

    Doping Contact: Anna Grassellino annag High quality factors (Q) are extremely important to accelerators with high duty factor, due to the infrastructure and operating costs of the cryogenic plant. In 2012, a process was discovered at FNAL to achieve unprecedented Q values by treating them in a high temperature

  16. Phase gradient metasurface with broadband anomalous reflection based on cross-shaped units

    NASA Astrophysics Data System (ADS)

    Chen, Zhaobin; Deng, Hui; Xiong, Qingxu; Liu, Chen

    2018-03-01

    It has been pointed out by many documents that a phase gradient metasurface with wideband characteristics can be designed by the unit with a low-quality factor ( Q value). In this paper, a cross-shaped unit with a low-quality factor Q is proposed. By changing the variable parameters of the unit, it is found that the reflection phase of the unit can achieve a stable distribution of phase gradient in the frequency range of 8.0-20.0 GHz. we analyze variation of the electromagnetic field distribution on the unit with frequency and find that the size along electrical field polarization of electromagnetic field distribution area changes with frequency. Based on our design, effective size of electromagnetic field distribution area keeps meeting the subwavelength condition, thus stable phase distribution is gained across broadened bandwidth. It is found by the analysis of the phase gradient metasurface composed of seven units that the metasurface can exhibit anomalous reflection in the wide frequency band of 8.0-20.0 GHz, and the efficiency of abnormal reflection is higher in the range of 10.0-18.0 GHz. The error between the simulation results of abnormal reflection angle and the theoretical result is only - 1.5° to 0.5° after the work of comparison. Therefore, the metasurface designed by the new cross-shaped unit has a good control on the deflection direction of the reflected wave, and shows obvious advantages in widening the bandwidth.

  17. Fabrication of an integrated high-quality-factor (high-Q) optofluidic sensor by femtosecond laser micromachining.

    PubMed

    Song, Jiangxin; Lin, Jintian; Tang, Jialei; Liao, Yang; He, Fei; Wang, Zhaohui; Qiao, Lingling; Sugioka, Koji; Cheng, Ya

    2014-06-16

    We report on fabrication of a microtoroid resonator of a high-quality factor (i.e., Q-factor of ~3.24 × 10(6) measured under the critical coupling condition) integrated in a microfluidic channel using femtosecond laser three-dimensional (3D) micromachining. Coupling of light into and out of the microresonator has been realized with a fiber taper that is reliably assembled with the microtoroid. The assembly of the fiber to the microtoroid is achieved by welding the fiber taper onto the sidewall of the microtoroid using CO2 laser irradiation. The integrated microresonator maintains a high Q-factor of 3.21 × 10(5) as measured in air, which should still be sufficient for many sensing applications. We test the functionality of the integrated optofluidic sensor by performing bulk refractive index sensing of purified water doped with tiny amount of salt. It is shown that a detection limit of ~1.2 × 10(-4) refractive index unit can be achieved. Our result showcases the capability of integration of high-Q microresonators with complex microfluidic systems using femtosecond laser 3D micromachining.

  18. SU-E-T-46: Application of a Twin-Detector Method for the Determination of the Mean Photon Energy Em at Points of Measurement in a Water Phantom Surrounding a GammaMed HDR 192Ir Brachytherapy Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chofor, N; Poppe, B; Nebah, F

    Purpose: In a brachytherapy photon field in water the fluence-averaged mean photon energy Em at the point of measurement correlates with the radiation quality correction factor kQ of a non water-equivalent detector. To support the experimental assessment of Em, we show that the normalized signal ratio NSR of a pair of radiation detectors, an unshielded silicon diode and a diamond detector can serve to measure quantity Em in a water phantom at a Ir-192 unit. Methods: Photon fluence spectra were computed in EGSnrc based on a detailed model of the GammaMed source. Factor kQ was calculated as the ratio ofmore » the detector's spectrum-weighted responses under calibration conditions at a 60Co unit and under brachytherapy conditions at various radial distances from the source. The NSR was investigated for a pair of a p-type unshielded silicon diode 60012 and a synthetic single crystal diamond detector 60019 (both PTW Freiburg). Each detector was positioned according to its effective point of measurement, with its axis facing the source. Lateral signal profiles were scanned under complete scatter conditions, and the NSR was determined as the quotient of the signal ratio under application conditions x and that at position r-ref = 1 cm. Results: The radiation quality correction factor kQ shows a close correlation with the mean photon energy Em. The NSR of the diode/diamond pair changes by a factor of two from 0–18 cm from the source, while Em drops from 350 to 150 keV. Theoretical and measured NSR profiles agree by ± 2 % for points within 5 cm from the source. Conclusion: In the presence of the close correlation between radiation quality correction factor kQ and photon mean energy Em, the NSR provides a practical means of assessing Em under clinical conditions. Precise detector positioning is the major challenge.« less

  19. Relationship and variation of qPCR and culturable enterococci estimates in ambient surface waters are predictable

    USGS Publications Warehouse

    Whitman, Richard L.; Ge, Zhongfu; Nevers, Meredith B.; Boehm, Alexandria B.; Chern, Eunice C.; Haugland, Richard A.; Lukasik, Ashley M.; Molina, Marirosa; Przybyla-Kelly, Kasia; Shively, Dawn A.; White, Emily M.; Zepp, Richard G.; Byappanahalli, Muruleedhara N.

    2010-01-01

    The quantitative polymerase chain reaction (qPCR) method provides rapid estimates of fecal indicator bacteria densities that have been indicated to be useful in the assessment of water quality. Primarily because this method provides faster results than standard culture-based methods, the U.S. Environmental Protection Agency is currently considering its use as a basis for revised ambient water quality criteria. In anticipation of this possibility, we sought to examine the relationship between qPCR-based and culture-based estimates of enterococci in surface waters. Using data from several research groups, we compared enterococci estimates by the two methods in water samples collected from 37 sites across the United States. A consistent linear pattern in the relationship between cell equivalents (CCE), based on the qPCR method, and colony-forming units (CFU), based on the traditional culturable method, was significant (P 10CFU > 2.0/100 mL) while uncertainty increases at lower CFU values. It was further noted that the relative error in replicated qPCR estimates was generally higher than that in replicated culture counts even at relatively high target levels, suggesting a greater need for replicated analyses in the qPCR method to reduce relative error. Further studies evaluating the relationship between culture and qPCR should take into account analytical uncertainty as well as potential differences in results of these methods that may arise from sample variability, different sources of pollution, and environmental factors.

  20. Near-threshold neutral pion electroproduction at high momentum transfers and generalized form factors

    NASA Astrophysics Data System (ADS)

    Khetarpal, P.; Stoler, P.; Aznauryan, I. G.; Kubarovsky, V.; Adhikari, K. P.; Adikaram, D.; Aghasyan, M.; Amaryan, M. J.; Anderson, M. D.; Anefalos Pereira, S.; Anghinolfi, M.; Avakian, H.; Baghdasaryan, H.; Ball, J.; Baltzell, N. A.; Battaglieri, M.; Batourine, V.; Bedlinskiy, I.; Biselli, A. S.; Bono, J.; Boiarinov, S.; Briscoe, W. J.; Brooks, W. K.; Burkert, V. D.; Carman, D. S.; Celentano, A.; Charles, G.; Cole, P. L.; Contalbrigo, M.; Crede, V.; D'Angelo, A.; Dashyan, N.; De Vita, R.; De Sanctis, E.; Deur, A.; Djalali, C.; Doughty, D.; Dugger, M.; Dupre, R.; Egiyan, H.; El Alaoui, A.; El Fassi, L.; Eugenio, P.; Fedotov, G.; Fegan, S.; Fersch, R.; Fleming, J. A.; Fradi, A.; Gabrielyan, M. Y.; Garçon, M.; Gevorgyan, N.; Gilfoyle, G. P.; Giovanetti, K. L.; Girod, F. X.; Goetz, J. T.; Gohn, W.; Golovatch, E.; Gothe, R. W.; Griffioen, K. A.; Guegan, B.; Guidal, M.; Guo, L.; Hafidi, K.; Hakobyan, H.; Hanretty, C.; Harrison, N.; Hicks, K.; Ho, D.; Holtrop, M.; Hyde, C. E.; Ilieva, Y.; Ireland, D. G.; Ishkhanov, B. S.; Isupov, E. L.; Jo, H. S.; Joo, K.; Keller, D.; Khandaker, M.; Kim, A.; Kim, W.; Klein, F. J.; Koirala, S.; Kubarovsky, A.; Kuleshov, S. V.; Kvaltine, N. D.; Lewis, S.; Livingston, K.; Lu, H. Y.; MacGregor, I. J. D.; Mao, Y.; Martinez, D.; Mayer, M.; McKinnon, B.; Meyer, C. A.; Mineeva, T.; Mirazita, M.; Mokeev, V.; Montgomery, R. A.; Moutarde, H.; Munevar, E.; Munoz Camacho, C.; Nadel-Turonski, P.; Nasseripour, R.; Niccolai, S.; Niculescu, G.; Niculescu, I.; Osipenko, M.; Ostrovidov, A. I.; Pappalardo, L. L.; Paremuzyan, R.; Park, K.; Park, S.; Pasyuk, E.; Phelps, E.; Phillips, J. J.; Pisano, S.; Pogorelko, O.; Pozdniakov, S.; Price, J. W.; Procureur, S.; Protopopescu, D.; Puckett, A. J. R.; Raue, B. A.; Ricco, G.; Rimal, D.; Ripani, M.; Rosner, G.; Rossi, P.; Sabatié, F.; Saini, M. S.; Salgado, C.; Saylor, N. A.; Schott, D.; Schumacher, R. A.; Seder, E.; Seraydaryan, H.; Sharabian, Y. G.; Smith, G. D.; Sober, D. I.; Sokhan, D.; Stepanyan, S. S.; Stepanyan, S.; Strakovsky, I. I.; Strauch, S.; Taiuti, M.; Tang, W.; Taylor, C. E.; Tkachenko, S.; Ungaro, M.; Vernarsky, B.; Voskanyan, H.; Voutier, E.; Walford, N. K.; Weinstein, L. B.; Weygand, D. P.; Wood, M. H.; Zachariou, N.; Zhang, J.; Zhao, Z. W.; Zonta, I.

    2013-04-01

    We report the measurement of near-threshold neutral pion electroproduction cross sections and the extraction of the associated structure functions on the proton in the kinematic range Q2 from 2 to 4.5 GeV2 and W from 1.08 to 1.16 GeV. These measurements allow us to access the dominant pion-nucleon s-wave multipoles E0+ and S0+ in the near-threshold region. In the light-cone sum-rule framework (LCSR), these multipoles are related to the generalized form factors G1π0p(Q2) and G2π0p(Q2). The data are compared to these generalized form factors and the results for G1π0p(Q2) are found to be in good agreement with the LCSR predictions, but the level of agreement with G2π0p(Q2) is poor.

  1. On the output factor measurements of the CyberKnife iris collimator small fields: Experimental determination of the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors for microchamber and diode detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pantelis, E.; Moutsatsos, A.; Zourari, K.

    Purpose: To measure the output factors (OFs) of the small fields formed by the variable aperture collimator system (iris) of a CyberKnife (CK) robotic radiosurgery system, and determine the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors for a microchamber and four diode detectors. Methods: OF measurements were performed using a PTW PinPoint 31014 microchamber, four diode detectors (PTW-60017, -60012, -60008, and the SunNuclear EDGE detector), TLD-100 microcubes, alanine dosimeters, EBT films, and polymer gels for the 5 mm, 7.5 mm, 10 mm, 12.5 mm, and 15 mm irismore » collimators at 650 mm, 800 mm, and 1000 mm source to detector distance (SDD). The alanine OF measurements were corrected for volume averaging effects using the 3D dose distributions registered in polymer gel dosimeters. k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors for the PinPoint microchamber and the diode dosimeters were calculated through comparison against corresponding polymer gel, EBT, alanine, and TLD results. Results: Experimental OF results are presented for the array of dosimetric systems used. The PinPoint microchamber was found to underestimate small field OFs, and a k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factor ranging from 1.127 {+-} 0.022 (for the 5 mm iris collimator) to 1.004 {+-} 0.010 (for the 15 mm iris collimator) was determined at the reference SDD of 800 mm. The PinPoint k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factor was also found to increase with decreasing SDD; k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} values equal to 1.220 {+-} 0.028 and 1.077 {+-} 0.016 were obtained for the 5 mm iris collimator at 650 mm and 1000 mm SDD, respectively. On the contrary, diode detectors were found to overestimate small field OFs and a correction factor equal to 0.973 {+-} 0.006, 0.954 {+-} 0.006, 0.937 {+-} 0.007, and 0.964 {+-} 0.006 was measured for the PTW-60017, -60012, -60008 and the EDGE diode detectors, respectively, for the 5 mm iris collimator at 800 mm SDD. The corresponding correction factors for the 15 mm iris collimator were found equal to 0.997 {+-} 0.010, 0.994 {+-} 0.009, 0.988 {+-} 0.010, and 0.986 {+-} 0.010, respectively. No correlation of the diode k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors with SDD was observed. Conclusions: This work demonstrates an experimental procedure for the determination of the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors required to obtain small field OF results of increased accuracy.« less

  2. SU-G-TeP1-03: Beam Quality Correction Factors for Linear Accelerator with and Without Flattening Filter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Czarnecki, D; Voigts-Rhetz, P von; Zink, K

    2016-06-15

    Purpose: The impact of removing the flattening filter on absolute dosimetry based on IAEA’s TPR-398 and AAPM’s TG-51 was investigated in this study using Monte Carlo simulations. Methods: The EGSnrc software package was used for all Monte Carlo simulations performed in this work. Five different ionization chambers and nine linear accelerator heads have been modeled according to technical drawings. To generate a flattening filter free radiation field the flattening filter was replaced by a 2 mm thick aluminum layer. Dose calculation in a water phantom were performed to calculate the beam quality correction factor k{sub Q} as a function ofmore » the beam quality specifiers %dd(10){sub x}, TPR{sub 20,10} and mean photon and electron energies at the point of measurement in photon fields with (WFF) and without flattening filter (FFF). Results: The beam quality correction factor as a function of %dd(10){sub x} differs systematically between FFF and WFF beams for all investigated ionization chambers. The largest difference of 1.8% was observed for the largest investigated Farmer-type ionization chamber with a sensitive volume of 0.69 cm{sup 3}. For ionization chambers with a smaller nominal sensitive volume (0.015 – 0.3 cm{sup 3}) the deviation was less than 0.4% between WFF and FFF beams for %dd(10){sub x} > 62%. The specifier TPR{sub 20,10} revealed only a good correlation between WFF and FFF beams (< 0.3%) for low energies. Conclusion: The results confirm that %dd(10){sub x} is a suitable beam quality specifier for FFF beams with an acceptable bias. The deviation depends on the volume of the ionization chamber. Using %dd(10){sub x} to predict k{sub Q} for a large volume chamber in a FFF photon field may lead to not acceptable errors according to the results of this study. This bias may be caused by the volume effect due to the inhomogeneous photon fields of FFF linear accelerators.« less

  3. The central electrode correction factor for high-Z electrodes in small ionization chambers.

    PubMed

    Muir, B R; Rogers, D W O

    2011-02-01

    Recent Monte Carlo calculations of beam quality conversion factors for ion chambers that use high-Z electrodes [B. R. Muir and D. W. O. Rogers, Med. Phys. 37, 5939-5950 (2010)] have shown large deviations of kQ values from values calculated using the same techniques as the TG-51 and TRS-398 protocols. This report investigates the central electrode correction factor, Pcel, for these chambers. Ionization chambers are modeled and Pcel is calculated using the EGSnrc user code egs_chamber for three cases: in photon and electron beams under reference conditions; as a function of distance from an iridium-192 point source in a water phantom; and as a function of depth in a water phantom on which a 200 kVp x-ray source or 6 MV beam is incident. In photon beams, differences of up to 3% between Pcel calculations for a chamber with a high-Z electrode and those used by TG-51 for a 1 mm diameter aluminum electrode are observed. The central electrode correction factor for a given value of the beam quality specifier is different depending on the amount of filtration of the photon beam. However, in an unfiltered 6 MV beam, Pcel, varies by only 0.3% for a chamber with a high-Z electrode as the depth is varied from 1 to 20 cm in water. The difference between Pcel calculations for chambers with high-Z electrodes and TG-51 values for a chamber with an aluminum electrode is up to 0.45% in electron beams. The central electrode correction, which is roughly proportional to the chambers absorbed dose sensitivity, is found to be large and variable as a function of distance for chambers with high-Z and aluminum electrodes in low-energy photon fields. In this work, ionization chambers that employ high-Z electrodes have been shown to be problematic in various situations. For beam quality conversion factors, the ratio of Pcel in a beam quality Q to that in a Co-60 beam is required; for some chambers, kQ is significantly different from current dosimetry protocol values because of central electrode effects. It would be best for manufacturers to avoid producing ion chambers that use high-Z electrodes.

  4. Diet quality is associated with disability and symptom severity in multiple sclerosis.

    PubMed

    Fitzgerald, Kathryn C; Tyry, Tuula; Salter, Amber; Cofield, Stacey S; Cutter, Gary; Fox, Robert; Marrie, Ruth Ann

    2018-01-02

    To assess the association between diet quality and intake of specific foods with disability and symptom severity in people with multiple sclerosis (MS). In 2015, participants in the North American Research Committee on MS (NARCOMS) Registry completed a dietary screener questionnaire that estimates intake of fruits, vegetables and legumes, whole grains, added sugars, and red/processed meats. We constructed an overall diet quality score for each individual based on these food groups; higher scores denoted a healthier diet. We assessed the association between diet quality and disability status as measured using Patient-Determined Disease Steps (PDDS) and symptom severity using proportional odds models, adjusting for age, sex, income, body mass index, smoking status, and disease duration. We assessed whether a composite healthy lifestyle measure, a healthier diet, healthy weight (body mass index <25), routine physical activity, and abstinence from smoking was associated with symptom severity. Of the 7,639 (68%) responders, 6,989 reported physician-diagnosed MS and provided dietary information. Participants with diet quality scores in the highest quintile had lower levels of disability (PDDS; proportional odds ratio [OR] for Q5 vs Q1 0.80; 95% confidence interval [CI] 0.69-0.93) and lower depression scores (proportional OR for Q5 vs Q1 0.82; 95% CI 0.70-0.97). Individuals reporting a composite healthy lifestyle had lower odds of reporting severe fatigue (0.69; 95% CI 0.59-0.81), depression (0.53; 95% CI 0.43-0.66), pain (0.56; 95% CI 0.48-0.67), or cognitive impairment (0.67; 95% CI 0.55-0.79). Our large cross-sectional survey suggests a healthy diet and a composite healthy lifestyle are associated with lesser disability and symptom burden in MS. Copyright © 2017 American Academy of Neurology.

  5. Factor VII R353Q genetic polymorphism is associated with altered warfarin sensitivity among CYP2C9 *1/*1 carriers.

    PubMed

    Mlynarsky, Liat; Bejarano-Achache, Idit; Muszkat, Mordechai; Caraco, Yoseph

    2012-05-01

    Warfarin responsiveness is characterized by marked interindividual variability. A major portion of this variability is attributed to CYP2C9 and VKORC1 polymorphisms, but almost 50% is still unaccounted for. This paper reports the first prospective study on the association between factor VII R353Q polymorphism and warfarin responsiveness during induction. Genotyping for factor VII R353Q and 323D/I polymorphisms was performed in a cohort consisting of 374 patients (198 CYP2C9*1/*1) treated with warfarin who were prospectively followed from warfarin initiation. Compared with *1/*1-R/R and *1/*1-R/Q genotype carriers, *1/*1-Q/Q homozygotes achieved higher International Normalized Ratio (INR) values while consuming lower warfarin doses. The greater sensitivity was illustrated by 82.1% higher Warfarin Sensitivity Index During Induction (WSIDI) (0.14 ± 0.11 vs. 0.08 ± 0.50 mg⁻¹ Mann-Whitney, P = 0.043). Multiple regression analysis consisting of both genetic and nongenetic factors explained 26% of WSIDI variability, with R353Q genetic polymorphism having a modest yet significant effect and accounting for 1.7% of the overall variability. Moreover, the incidence of overanticoagulation (i.e., INR > 4) was 6.94-fold higher among *1/*1-Q/Q vs. *1/*1-R/R&R/Q carriers during warfarin induction (Pearson chi-square, P = 0.005). These findings were not accounted for by a chance difference in the distribution of VKORC1 genotypes. Analysis of these parameters among the entire cohort, including CYP2C9*2 and CYP2C9*3 variant allele carriers, did not reach statistical significance. Warfarin responsiveness during induction was unrelated to factor VII 323D/I genetic polymorphism. The response to warfarin during induction is influenced by factor VII R353Q polymorphism. The prospective use of this polymorphism, along with CYP2C9 and VKORC1, may enhance the accuracy of warfarin loading. However, the impact of R353Q polymorphism on overall warfarin response is subtle, and it is therefore unlikely that its use would be of clinical importance.

  6. High field Q slope and the effect of low-temperature baking at 3 GHz

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ciovati, G.; Eremeev, G.; Hannon, F.

    Here, a strong degradation of the unloaded quality factor with field, called high field Q-slope, is commonly observed above Bmore » $$_{p}$$ $$\\cong$$ 100 mT in elliptical superconducting niobium cavities at 1.3 GHz and 1.5 GHz. In the present experiments several 3 GHz niobium cavities were measured up to and above B$$_{p}$$ $$\\cong$$100 mT. The measurements show that a high field Q-slope phenomenon limits the field reach at this frequency, that the high field Q-slope onset field depends weakly on the frequency, and that the high field Q-slope can be removed by the typical empirical solution of electropolishing followed by heating to 120 $$^{\\circ}$$C for 48 hrs. In addition, one of the cavities reached a quench field of 174~mT and its field dependence of the quality factor was compared against global heating predicted by a thermal feedback model.« less

  7. High field Q slope and the effect of low-temperature baking at 3 GHz

    DOE PAGES

    Ciovati, G.; Eremeev, G.; Hannon, F.

    2018-01-29

    Here, a strong degradation of the unloaded quality factor with field, called high field Q-slope, is commonly observed above Bmore » $$_{p}$$ $$\\cong$$ 100 mT in elliptical superconducting niobium cavities at 1.3 GHz and 1.5 GHz. In the present experiments several 3 GHz niobium cavities were measured up to and above B$$_{p}$$ $$\\cong$$100 mT. The measurements show that a high field Q-slope phenomenon limits the field reach at this frequency, that the high field Q-slope onset field depends weakly on the frequency, and that the high field Q-slope can be removed by the typical empirical solution of electropolishing followed by heating to 120 $$^{\\circ}$$C for 48 hrs. In addition, one of the cavities reached a quench field of 174~mT and its field dependence of the quality factor was compared against global heating predicted by a thermal feedback model.« less

  8. High-Q photonic resonators and electro-optic coupling using silicon-on-lithium-niobate

    PubMed Central

    Witmer, Jeremy D.; Valery, Joseph A.; Arrangoiz-Arriola, Patricio; Sarabalis, Christopher J.; Hill, Jeff T.; Safavi-Naeini, Amir H.

    2017-01-01

    Future quantum networks, in which superconducting quantum processors are connected via optical links, will require microwave-to-optical photon converters that preserve entanglement. A doubly-resonant electro-optic modulator (EOM) is a promising platform to realize this conversion. Here, we present our progress towards building such a modulator by demonstrating the optically-resonant half of the device. We demonstrate high quality (Q) factor ring, disk and photonic crystal resonators using a hybrid silicon-on-lithium-niobate material system. Optical Q factors up to 730,000 are achieved, corresponding to propagation loss of 0.8 dB/cm. We also use the electro-optic effect to modulate the resonance frequency of a photonic crystal cavity, achieving a electro-optic modulation coefficient between 1 and 2 pm/V. In addition to quantum technology, we expect that our results will be useful both in traditional silicon photonics applications and in high-sensitivity acousto-optic devices. PMID:28406177

  9. Sediment contamination of residential streams in the metropolitan kansas city area, USA: Part II. whole-sediment toxicity to the amphipod hyalella azteca

    USGS Publications Warehouse

    Tao, J.; Ingersoll, C.G.; Kemble, N.E.; Dias, J.R.; Murowchick, J.B.; Welker, G.; Huggins, D.

    2010-01-01

    This is the second part of a study that evaluates the influence of nonpoint sources on the sediment quality of five adjacent streams within the metropolitan Kansas City area, central United States. Physical, chemical, and toxicity data (Hyalella azteca 28-day whole-sediment toxicity test) for 29 samples collected in 2003 were used for this evaluation, and the potential causes for the toxic effects were explored. The sediments exhibited a low to moderate toxicity, with five samples identified as toxic to H. azteca. Metals did not likely cause the toxicity based on low concentrations of metals in the pore water and elevated concentrations of acid volatile sulfide in the sediments. Although individual polycyclic aromatic hydrocarbons (PAHs) frequently exceeded effect-based sediment quality guidelines [probable effect concentrations (PECs)], only four of the samples had a PEC quotient (PEC-Q) for total PAHs over 1.0 and only one of these four samples was identified as toxic. For the mean PEC-Q for organochlorine compounds (chlordane, dieldrin, sum DDEs), 4 of the 12 samples with a mean PEC-Q above 1.0 were toxic and 4 of the 8 samples with a mean PEC-Q above 3.0 were toxic. Additionally, four of eight samples were toxic, with a mean PEC-Q above 1.0 based on metals, PAHs, polychlorinated biphenyls (PCBs), and organochlorine pesticides. The increase in the incidence of toxicity with the increase in the mean PEC-Q based on organochlorine pesticides or based on metals, PAHs, PCBs, and organochlorine pesticides suggests that organochlorine pesticides might have contributed to the observed toxicity and that the use of a mean PEC-Q, rather than PEC-Qs for individual compounds, might be more informative in predicting toxic effects. Our study shows that stream sediments subject to predominant nonpoint sources contamination can be toxic and that many factors, including analysis of a full suite of PAHs and pesticides of both past and present urban applications and the origins of these organic compounds, are important to identify the causes of toxicity. ?? 2010 Springer Science+Business Media, LLC.

  10. DockQ: A Quality Measure for Protein-Protein Docking Models

    PubMed Central

    Basu, Sankar

    2016-01-01

    The state-of-the-art to assess the structural quality of docking models is currently based on three related yet independent quality measures: Fnat, LRMS, and iRMS as proposed and standardized by CAPRI. These quality measures quantify different aspects of the quality of a particular docking model and need to be viewed together to reveal the true quality, e.g. a model with relatively poor LRMS (>10Å) might still qualify as 'acceptable' with a descent Fnat (>0.50) and iRMS (<3.0Å). This is also the reason why the so called CAPRI criteria for assessing the quality of docking models is defined by applying various ad-hoc cutoffs on these measures to classify a docking model into the four classes: Incorrect, Acceptable, Medium, or High quality. This classification has been useful in CAPRI, but since models are grouped in only four bins it is also rather limiting, making it difficult to rank models, correlate with scoring functions or use it as target function in machine learning algorithms. Here, we present DockQ, a continuous protein-protein docking model quality measure derived by combining Fnat, LRMS, and iRMS to a single score in the range [0, 1] that can be used to assess the quality of protein docking models. By using DockQ on CAPRI models it is possible to almost completely reproduce the original CAPRI classification into Incorrect, Acceptable, Medium and High quality. An average PPV of 94% at 90% Recall demonstrating that there is no need to apply predefined ad-hoc cutoffs to classify docking models. Since DockQ recapitulates the CAPRI classification almost perfectly, it can be viewed as a higher resolution version of the CAPRI classification, making it possible to estimate model quality in a more quantitative way using Z-scores or sum of top ranked models, which has been so valuable for the CASP community. The possibility to directly correlate a quality measure to a scoring function has been crucial for the development of scoring functions for protein structure prediction, and DockQ should be useful in a similar development in the protein docking field. DockQ is available at http://github.com/bjornwallner/DockQ/ PMID:27560519

  11. Quench Studies of Six High Temperature Nitrogen Doped 9 Cell Cavities for Use in the LCLS-II Baseline Prototype Cryomodule at Jefferson Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Palczewski, Ari; Geng, Rongli; Eremeev, Grigory

    Jefferson Lab (JLab) processed six nine-cell cavities as part of a small-scale production for LCLS-II cavity processing development utilizing the promising nitrogen-doping process. Various nitrogen-doping recipes have been scrutinized to optimize process parameters with the aim to guarantee an unloaded quality factor (Q_0) of 2.7∙10 10 at an accelerating field (Eacc) of 16 MV/m at 2.0 K in the cryomodule. During the R&D phase the characteristic Q0 vs. Eacc performance curve of the cavities has been measured in JLab’s vertical test area at 2 K. The findings showed the characteristic rise of the Q0 with Eacc as expected from nitrogen-doping.more » Initially, five cavities achieved an average Q0 of 3.3·10 10 at the limiting Eacc averaging to 16.8 MV/m, while one cavity experienced an early quench accompanied by an unusual Q_0 vs. Eacc curve. The project accounts for a cavity performance loss from the vertical dewar test (with or without the helium vessel) to the horizontal performance in a cryomodule, such that these results leave no save margin to the cryomodule specification. Consequently, a refinement of the nitrogen-doping has been initiated to guarantee an average quench field above 20 MV/m without impeding the Q_0. This paper covers the refinement work performed for each cavity, which depends on the initial results, as well as a quench analysis carried out before and after the rework during the vertical RF tests as far as applicable.« less

  12. Encapsulated high frequency (235 kHz), high-Q (100 k) disk resonator gyroscope with electrostatic parametric pump

    NASA Astrophysics Data System (ADS)

    Ahn, C. H.; Nitzan, S.; Ng, E. J.; Hong, V. A.; Yang, Y.; Kimbrell, T.; Horsley, D. A.; Kenny, T. W.

    2014-12-01

    In this paper, we explore the effects of electrostatic parametric amplification on a high quality factor (Q > 100 000) encapsulated disk resonator gyroscope (DRG), fabricated in <100> silicon. The DRG was operated in the n = 2 degenerate wineglass mode at 235 kHz, and electrostatically tuned so that the frequency split between the two degenerate modes was less than 100 mHz. A parametric pump at twice the resonant frequency is applied to the sense axis of the DRG, resulting in a maximum scale factor of 156.6 μV/(°/s), an 8.8× improvement over the non-amplified performance. When operated with a parametric gain of 5.4, a minimum angle random walk of 0.034°/√h and bias instability of 1.15°/h are achieved, representing an improvement by a factor of 4.3× and 1.5×, respectively.

  13. [The salivary factors related to caries and periodontal disease in children and adolescents with diabetes mellitus].

    PubMed

    Wang, Meng-xing; Wang, Xin; Zhang, Zhi; Qin, Man

    2013-09-01

    To detect the salivary factors related to caries and periodontal disease and to analyze the risk of caries and periodontal disease in children and adolescents with diabetes mellitus. The study comprised 30 children with diabetic mellitus, aged 7-15 years old, and 60 healthy age-and gender-matched children. Caries and periodontal indexes were recorded and saliva related factors were analyzed. Caries indexes of diabetes children [permanent teeth: decay missing filling tooth (DMFT) M (Q1,Q3) = 0(0, 4), deciduous teeth: decay missing filling tooth (dmft) M (Q1,Q3) = 0(0, 1)] were not significantly different with those of healthy children [DMFT M (Q1,Q3) = 1(0, 3), dmft M (Q1,Q3) = 0(0, 4)], but plaque index (PLI) (1.25 ± 0.33) and bleeding index (BI) (0.74 ± 0.45) of diabetes children were significantly higher than those of healthy children (PLI was 0.93 ± 0.31,BI was 0.34 ± 0.22) (P < 0.001). Salivary pH of diabetes children (7.68 ± 0.36) was significantly higher than that of healthy children (7.30 ± 0.32) (P < 0.05), and salivary acid buffering capacity had no significant difference between the two groups (P > 0.05). Salivary glucose, immunoglobulin sIgA and sIgG were not significantly different between the two groups (P > 0.05).Salivary lysozyme of diabetes children was significantly higher than that of healthy children (P < 0.05). Total protein was significantly lower in diabetes children than in healthy children (P < 0.05). Salivary lactate dehydrogenase had no significant difference between the two groups (P > 0.05). Diabetes mellitus can lead to the changes of some salivary factors related to gingivitis in diabetes children. Children and adolescents with diabetes mellitus may have a higher risk of periodontal disease.

  14. Near-source attenuation of high-frequency body waves beneath the New Madrid Seismic Zone

    NASA Astrophysics Data System (ADS)

    Pezeshk, Shahram; Sedaghati, Farhad; Nazemi, Nima

    2018-03-01

    Attenuation characteristics in the New Madrid Seismic Zone (NMSZ) are estimated from 157 local seismograph recordings out of 46 earthquakes of 2.6 ≤ M ≤ 4.1 with hypocentral distances up to 60 km and focal depths down to 25 km. Digital waveform seismograms were obtained from local earthquakes in the NMSZ recorded by the Center for Earthquake Research and Information (CERI) at the University of Memphis. Using the coda normalization method, we tried to determine Q values and geometrical spreading exponents at 13 center frequencies. The scatter of the data and trade-off between the geometrical spreading and the quality factor did not allow us to simultaneously derive both these parameters from inversion. Assuming 1/ R 1.0 as the geometrical spreading function in the NMSZ, the Q P and Q S estimates increase with increasing frequency from 354 and 426 at 4 Hz to 729 and 1091 at 24 Hz, respectively. Fitting a power law equation to the Q estimates, we found the attenuation models for the P waves and S waves in the frequency range of 4 to 24 Hz as Q P = (115.80 ± 1.36) f (0.495 ± 0.129) and Q S = (161.34 ± 1.73) f (0.613 ± 0.067), respectively. We did not consider Q estimates from the coda normalization method for frequencies less than 4 Hz in the regression analysis since the decay of coda amplitude was not observed at most bandpass filtered seismograms for these frequencies. Q S/ Q P > 1, for 4 ≤ f ≤ 24 Hz as well as strong intrinsic attenuation, suggest that the crust beneath the NMSZ is partially fluid-saturated. Further, high scattering attenuation indicates the presence of a high level of small-scale heterogeneities inside the crust in this region.

  15. Attenuation Characteristics of High Frequency Seismic Waves in Southern India

    NASA Astrophysics Data System (ADS)

    Sivaram, K.; Utpal, Saikia; Kanna, Nagaraju; Kumar, Dinesh

    2017-07-01

    We present a systematic study of seismic attenuation and its related Q structure derived from the spectral analysis of P-, S-waves in the southern India. The study region is separated into parts of EDC (Eastern Dharwar Craton), Western Dharwar Craton (WDC) and Southern Granulite Terrain (SGT). The study is carried out in the frequency range 1-20 Hz, using a single-station spectral ratio technique. We make use of about 45 earthquakes, recorded in a network of about 32 broadband 3-component seismograph-stations, having magnitudes ( M L) varying from 1.6 to 4.5, to estimate the average seismic body wave attenuation quality factors; Q P and Q S. Their estimated average values are observed to be fitting to the power law form of Q = Q 0 f n . The averaged power law relations for Southern Indian region (as a whole) are obtained as Q P = (95 ± 1.12) f (1.32±0.01); Q S = (128 ± 1.84) f (1.49±0.01). Based on the stations and recorded local earthquakes, for parts of EDC, WDC and SGT, the average power law estimates are obtained as: Q P = (97 ± 5) f (1.40±0.03), Q S = (116 ± 1.5) f (1.48±0.01) for EDC region; Q P = (130 ± 7) f (1.20±0.03), Q S = (103 ± 3) f (1.49±0.02) for WDC region; Q P = (68 ± 2) f (1.4±0.02), Q S = (152 ± 6) f (1.48±0.02) for SGT region. These estimates are weighed against coda Q ( Q C) estimates, using the coda decay technique, which is based on a weak backscattering of S-waves. A major observation in the study of body wave analysis is the low body wave Q ( Q 0 < 200), moderately high value of the frequency-exponent, ` n' (>0.5) and Q S/ Q P ≫ 1, suggesting lateral stretches of dominant scattering mode of seismic wave propagation. This primarily could be attributed to possible thermal anomalies and spread of partially fluid-saturated rock-masses in the crust and upper mantle of the southern Indian region, which, however, needs further laboratory studies. Such physical conditions might partly be correlated to the active seismicity and intraplate tectonism, especially in SGT and EDC regions, as per the observed low- Q P and Q S values. Additionally, the enrichment of coda waves and significance of scattering mechanisms is evidenced in our observation of Q C > Q S estimates. Lapse time study shows Q C values increasing with lapse time. High Q C values at 40 s lapse times in WDC indicate that it may be a relatively stable region. In the absence of detailed body wave attenuation studies in this region, the frequency dependent Q relationships developed here are useful for the estimation of earthquake source parameters of the region. Also, these relations may be used for the simulation of earthquake strong ground motions which are required for the estimation of seismic hazard, geotechnical and retrofitting analysis of critical structures in the region.

  16. Correction of stopping power and LET quenching for radiophotoluminescent glass dosimetry in a therapeutic proton beam

    NASA Astrophysics Data System (ADS)

    Chang, Weishan; Koba, Yusuke; Katayose, Tetsurou; Yasui, Keisuke; Omachi, Chihiro; Hariu, Masatsugu; Saitoh, Hidetoshi

    2017-12-01

    To measure the absorbed dose to water D w in proton beams using a radiophotoluminescent glass dosimeter (RGD), a method with the correction for the change of the mass stopping power ratio (SPR) and the linear energy transfer (LET) dependence of radiophotoluminescent efficiency \\varepsilon LETRGD is proposed. The calibration coefficient in terms of D w for RGDs (GD-302M, Asahi Techno Glass) was obtained using a 60Co γ-ray. The SPR of water to the RGD was calculated by Monte Carlo simulation, and \\varepsilon LETRGD was investigated experimentally using a 70 MeV proton beam. For clinical usage, the residual range R res was used as a quality index to determine the correction factor for the beam quality kQ,{{Q0}}RGD and the LET quenching effect of the RGD kLETRGD . The proposed method was evaluated by measuring D w at different depths in a 200 MeV proton beam. For both non-modulated and modulated proton beams, kQ,{{Q0}}RGD decreases rapidly where R res is less than 4 cm. The difference in kQ,{{Q0}}RGD between a non-modulated and a modulated proton beam is less than 0.5% for the R res range from 0 cm to 22 cm. \\varepsilon LETRGD decreases rapidly at a LET range from 1 to 2 keV µm-1. In the evaluation experiments, D w using RGDs, Dw,QRGD showed good agreement with that obtained using an ionization chamber and the relative difference was within 3% where R res was larger than 1 cm. The uncertainty budget for Dw,QRGD in a proton beam was estimated to investigate the potential of RGD postal dosimetry in proton therapy. These results demonstrate the feasibility of RGD dosimetry in a therapeutic proton beam and the general versatility of the proposed method. In conclusion, the proposed methodology for RGDs in proton dosimetry is applicable where R res  >  1 cm and the RGD is feasible as a postal audit dosimeter for proton therapy.

  17. Extremely Low Loss Phonon-Trapping Cryogenic Acoustic Cavities for Future Physical Experiments

    PubMed Central

    Galliou, Serge; Goryachev, Maxim; Bourquin, Roger; Abbé, Philippe; Aubry, Jean Pierre; Tobar, Michael E.

    2013-01-01

    Low loss Bulk Acoustic Wave devices are considered from the point of view of the solid state approach as phonon-confining cavities. We demonstrate effective design of such acoustic cavities with phonon-trapping techniques exhibiting extremely high quality factors for trapped longitudinally-polarized phonons of various wavelengths. Quality factors of observed modes exceed 1 billion, with a maximum Q-factor of 8 billion and Q × f product of 1.6 · 1018 at liquid helium temperatures. Such high sensitivities allow analysis of intrinsic material losses in resonant phonon systems. Various mechanisms of phonon losses are discussed and estimated. PMID:23823569

  18. The microbial temperature sensitivity to warming is controlled by thermal adaptation and is independent of C-quality across a pan-continental survey

    NASA Astrophysics Data System (ADS)

    Berglund, Eva; Rousk, Johannes

    2017-04-01

    Climate models predict that warming will result in an increased loss of soil organic matter (SOM). However, field experiments suggest that although warming results in an immediate increase in SOM turnover, the effect diminishes over time. Although the use and subsequent turnover of SOM is dominated by the soil microbial community, the underlying physiology underpinning warming responses are not considered in current climate models. It has been suggested that a reduction in the perceived quality of SOM to the microbial community, and changes in the microbial thermal adaptation, could be important feed-backs to soil warming. Thus, studies distinguishing between temperature relationships and how substrate quality influences microbial decomposition are a priority. We examined microbial communities and temperature sensitivities along a natural climate gradient including 56 independent samples from across Europe. The gradient included mean annual temperatures (MAT) from ca -4 to 18 ˚ C, along with wide spans of environmental factors known to influence microbial communities, such as pH (4.0 to 8.8), nutrients (C/N from 7 to 50), SOM (from 4 to 94%), and plant communities, etc. The extensive ranges of environmental conditions resulted in wide ranges of substrate quality, indexed as microbial respiration per unit SOM, from 5-150 μg CO2g-1 SOM g-1 h-1. We hypothesised microbial communities to (1) be adapted to the temperature of their climate, leading to warm adapted bacterial communities that were more temperature sensitive (higher Q10s) at higher MAT; (2) have temperature sensitivities affected by the quality of SOM, with higher Q10s for lower quality SOM. To determine the microbial use of SOM and its dependence on temperature, we characterized microbial temperature dependences of bacterial growth (leu inc), fungal growth (ac-in-erg) and soil respiration in all 56 sites. Temperature dependences were determined using brief (ca. 1-2 h at 25˚ C) laboratory incubation experiments including temperatures from 0 to 35˚ C. Temperature relationships were modelled using the Ratkowsky model, and cardinal points including minimum temperature (Tmin) for growth and respiration along with temperature sensitivity (Q10) values were used as indices to compare sites. Microbial communities were cold-adapted in cold sites and warm-adapted in warm sites, as shown by Tmin values ranging from ca. -20 ˚ C to 0 ˚ C. For every 1˚ C rise in MAT, Tmin increased by 0.22˚ C and 0.28˚ C for bacteria and fungi, respectively. Soil respiration was less dependent on MAT, increasing 0.16 ˚ C per 1˚ C. Temperature dependence analyses grew stronger when regressed against summer temperatures, and weaker when regressed against winter temperatures. Hence, microbial communities adjusted their temperature dependence for growth more than for respiration, and higher temperatures had more impact than low temperatures did. The correlation between Tmin and MAT resulted in Q10s increasing with MAT, showing that microorganisms from cold regions were less temperature sensitive than those from warmer regions. For every 1˚ C increase in MAT, Q10 increased with 0.04 and 0.03 units for bacterial and fungal growth respectively, and 0.08 units for soil respiration. In contrast to previous studies, we found no relationship between temperature sensitivity and substrate quality. We demonstrate that the strongest driver of variation in microbial temperatures sensitivities (Q10s) is the microbial adaptation to its thermal environment. Surprisingly, the quality of SOM had no influence on the temperature sensitivity. This calls for a revision of the understanding for how microbial decomposers feed-back to climate warming. Specifically, the thermal adaptation of microbial communities need to be incorporated into climate models to capture responses to warming, while the quality of SOM can be ignored.

  19. Quality of initial HIV care in Canada: extension of a composite programmatic assessment tool for HIV therapy.

    PubMed

    Kesselring, S; Cescon, A; Colley, G; Osborne, C; Zhang, W; Raboud, J M; Hosein, S R; Burchell, A N; Cooper, C; Klein, M B; Loutfy, M; Machouf, N; Montaner, Jsg; Rachlis, A; Tsoukas, C; Hogg, R S; Lima, V D

    2017-03-01

    To document the quality of initial HIV care in Canada using the Programmatic Compliance Score (PCS), to explore the association of the PCS with mortality, and to identify factors associated with higher quality of care. We analysed data from the Canadian Observational Cohort Collaboration (CANOC), a multisite Canadian cohort of HIV-positive adults initiating combination antiretroviral therapy (ART) from 2000 to 2011. PCS indicators of noncompliance with HIV treatment guidelines include: fewer than three CD4 count tests in the first year of ART; fewer than three viral load tests in the first year of ART; no drug resistance testing before initiation; baseline CD4 count < 200 cells/mm 3 ; starting a nonrecommended ART regimen; and not achieving viral suppression within 6 months of initiation. Indicators are summed for a score from 0 to 6; higher scores indicate poorer care. Cox regression was used to assess the association between PCS and mortality and ordinal logistic regression was used to explore factors associated with higher quality of care. Of the 7460 participants (18% female), the median score was 1.0 (Q1-Q3 1.0-2.0); 21% scored 0 and 8% scored ≥ 4. In multivariable analysis, compared with a score of 0, poorer PCS was associated with mortality for scores > 1 [score = 2: adjusted hazard ratio (AHR) 1.64; 95% confidence interval (CI) 1.13-2.36; score = 3: AHR 2.02; 95% CI 1.38-2.97; score ≥ 4: AHR 2.14; 95% CI 1.43-3.21], after adjustments for age, sex, province, ART start year, hepatitis C virus (HCV) coinfection, and baseline viral load. Women, individuals with HCV coinfection, younger people, and individuals starting ART earlier (2000-2003) had poorer scores. Our findings further validate the PCS as a predictor of all-cause mortality. Disparities identified suggest that further efforts are needed to ensure that care is equitably accessible. © 2016 British HIV Association.

  20. Hadamard Factorization of Stable Polynomials

    NASA Astrophysics Data System (ADS)

    Loredo-Villalobos, Carlos Arturo; Aguirre-Hernández, Baltazar

    2011-11-01

    The stable (Hurwitz) polynomials are important in the study of differential equations systems and control theory (see [7] and [19]). A property of these polynomials is related to Hadamard product. Consider two polynomials p,q ∈ R[x]:p(x) = anxn+an-1xn-1+...+a1x+a0q(x) = bmx m+bm-1xm-1+...+b1x+b0the Hadamard product (p × q) is defined as (p×q)(x) = akbkxk+ak-1bk-1xk-1+...+a1b1x+a0b0where k = min(m,n). Some results (see [16]) shows that if p,q ∈R[x] are stable polynomials then (p×q) is stable, also, i.e. the Hadamard product is closed; however, the reciprocal is not always true, that is, not all stable polynomial has a factorization into two stable polynomials the same degree n, if n> 4 (see [15]).In this work we will give some conditions to Hadamard factorization existence for stable polynomials.

  1. Absorption band Q model for the Earth

    NASA Technical Reports Server (NTRS)

    Anderson, D. L.; Given, J. W.

    1981-01-01

    Attenuation in solids and liquids, as measured by the quality factor Q, is typically frequency dependent. In seismology, however, Q is usually assumed to be independent of frequency. Body wave, surface wave, and normal mode data are used to place constraints on the frequency dependence of Q in the mantle. Specific features of the absorption band model are: low-Q in the seismic band at both the top and the base of the mantle, low-Q for long-period body waves in the outer core, an inner core Q sub s that increases with period, and low Q sub p/Q sub s at short periods in the middle mantle.

  2. Healthy eating and reduced risk of cognitive decline

    PubMed Central

    Dehghan, Mahshid; O'Donnell, Martin; Anderson, Craig; Teo, Koon; Gao, Peggy; Sleight, Peter; Dagenais, Gilles; Probstfield, Jeffrey L.; Mente, Andrew; Yusuf, Salim

    2015-01-01

    Objective: We sought to determine the association of dietary factors and risk of cognitive decline in a population at high risk of cardiovascular disease. Methods: Baseline dietary intake and measures of the Mini-Mental State Examination were recorded in 27,860 men and women who were enrolled in 2 international parallel trials of the ONTARGET (Ongoing Telmisartan Alone and in Combination with Ramipril Global Endpoint Trial) and TRANSCEND (Telmisartan Randomised Assessment Study in ACE Intolerant Subjects with Cardiovascular Disease) studies. We measured diet quality using the modified Alternative Healthy Eating Index. Cox proportional hazards regression was used to determine the association between diet quality and risk of ≥3-point decline in Mini-Mental State Examination score, and reported as hazard ratio with 95% confidence intervals with adjustment for covariates. Results: During 56 months of follow-up, 4,699 cases of cognitive decline occurred. We observed lower risk of cognitive decline among those in the healthiest dietary quintile of modified Alternative Healthy Eating Index compared with lowest quintile (hazard ratio 0.76, 95% confidence interval 0.66–0.86, Q5 vs Q1). Lower risk of cognitive decline was consistent regardless of baseline cognitive level. Conclusion: We found that higher diet quality was associated with a reduced risk of cognitive decline. Improved diet quality represents an important potential target for reducing the global burden of cognitive decline. PMID:25948720

  3. Thermoelastic Damping in Cone Microcantilever Resonator

    NASA Astrophysics Data System (ADS)

    Li, Pu; Zhou, Hongyue

    2017-07-01

    Microbeams with continuous or discontinuous variable cross-section have been applied in Microelectromechanical Systems (MEMS) resonators, such as tapered microbeam, torsion microbeam and stepped microbeam. Thermoelastic damping (TED), which is verified as a fundamental energy lost mechanism for microresonators, is calculated by the Zener’s model and Lifshits and Roukes’s (LR) model in general. However, for non-uniform microbeam resonators, these two classical models are not suitable in some cases. On the basis of Zener’s theory, a TED model for cone microcantilever with rectangular cross-section has been derived in this study. The comparison of results obtained by the present model and Finite Element Method (FEM) model proves that the proposed model is able to predict TED value for cone microcantilever. In addition, TED in cone microcantilever is nearly same as TED in wedge microcantilever. The results show that quality factors (Q-factors) of cone microcantilever and wedge microcantilever are larger than Q-factor of uniform microbeam at low frequencies. The Debye peak value of a uniform microcantilever is equal to 0.5Δ E , while those of cone microcantilever and wedge microcantilever are about 0.438ΔE and 0.428ΔE, respectively.

  4. Influence of growing altitude, shade and harvest period on quality and biochemical composition of Ethiopian specialty coffee.

    PubMed

    Tolessa, Kassaye; D'heer, Jolien; Duchateau, Luc; Boeckx, Pascal

    2017-07-01

    Coffee quality is a key characteristic for the international market, comprising cup quality and chemical bean constituents. In Ethiopia, using total specialty cup scores, coffees are grouped into Q1 (specialty 1) ≥ 85 and Q2 (80-84.75). This classification results in market segmentation and higher prices. Although different studies have evaluated the effects of altitude and shade on bean quality, optimum shade levels along different altitudinal ranges are not clearly indicated. Information on effects of harvest periods on coffee quality is also scanty. The present study examined the influences of these factors and their interactions on Ethiopian coffee quality RESULTS: Coffee from high altitude with open or medium shade and early to middle harvest periods had a superior bean quality. These growing conditions also favoured the production of beans with lower caffeine. An increasing altitude, from mid to high, at approximately 400 m, decreased caffeine content by 10%. At high altitude, dense shade decreased Q1 coffee by 50%. Compared to late harvesting, early harvesting increased the percentage from 27% to 73%. At mid altitude, > 80% is Q2 coffee. Changes of quality scores driven by altitude, shade and harvest period are small, although they may induce dramatic switches in the fraction Q1 versus Q2 coffee. The latter affects both farmers' profits and competitiveness in international markets. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  5. Extraction of the neutron magnetic form factor from quasielastic 3He→(e→,e') at Q2=0.1-0.6(GeV/c)2

    NASA Astrophysics Data System (ADS)

    Anderson, B.; Auberbach, L.; Averett, T.; Bertozzi, W.; Black, T.; Calarco, J.; Cardman, L.; Cates, G. D.; Chai, Z. W.; Chen, J. P.; Choi, Seonho; Chudakov, E.; Churchwell, S.; Corrado, G. S.; Crawford, C.; Dale, D.; Deur, A.; Djawotho, P.; Dutta, D.; Finn, J. M.; Gao, H.; Gilman, R.; Glamazdin, A. V.; Glashausser, C.; Glöckle, W.; Golak, J.; Gomez, J.; Gorbenko, V. G.; Hansen, J.-O.; Hersman, F. W.; Higinbotham, D. W.; Holmes, R.; Howell, C. R.; Hughes, E.; Humensky, B.; Incerti, S.; Jager, C. W. De; Jensen, J. S.; Jiang, X.; Jones, C. E.; Jones, M.; Kahl, R.; Kamada, H.; Kievsky, A.; Kominis, I.; Korsch, W.; Kramer, K.; Kumbartzki, G.; Kuss, M.; Lakuriqi, E.; Liang, M.; Liyanage, N.; Lerose, J.; Malov, S.; Margaziotis, D. J.; Martin, J. W.; McCormick, K.; McKeown, R. D.; McIlhany, K.; Meziani, Z.-E.; Michaels, R.; Miller, G. W.; Mitchell, J.; Nanda, S.; Pace, E.; Pavlin, T.; Petratos, G. G.; Pomatsalyuk, R. I.; Pripstein, D.; Prout, D.; Ransome, R. D.; Roblin, Y.; Rvachev, M.; Saha, A.; Salmè, G.; Schnee, M.; Seely, J.; Shin, T.; Slifer, K.; Souder, P. A.; Strauch, S.; Suleiman, R.; Sutter, M.; Tipton, B.; Todor, L.; Viviani, M.; Vlahovic, B.; Watson, J.; Williamson, C. F.; Witała, H.; Wojtsekhowski, B.; Xiong, F.; Xu, W.; Yeh, J.; Żołnierczuk, P.

    2007-03-01

    We have measured the transverse asymmetry AT' in the quasielastic 3He→(e→,e') process with high precision at Q2 values from 0.1 to 0.6(GeV/c)2. The neutron magnetic form factor GMn was extracted at Q2 values of 0.1 and 0.2(GeV/c)2 using a nonrelativistic Faddeev calculation which includes both final-state interactions (FSI) and meson-exchange currents (MEC). Theoretical uncertainties due to the FSI and MEC effects were constrained with a precision measurement of the spin-dependent asymmetry in the threshold region of 3He→(e→,e'). We also extracted the neutron magnetic form factor GMn at Q2 values of 0.3 to 0.6(GeV/c)2 based on plane wave impulse approximation calculations.

  6. Saitohin Q7R polymorphism is associated with late-onset Alzheimer's disease susceptibility among caucasian populations: a meta-analysis.

    PubMed

    Huang, Rong; Tian, Sai; Cai, Rongrong; Sun, Jie; Xia, Wenqing; Dong, Xue; Shen, Yanjue; Wang, Shaohua

    2017-08-01

    Saitohin (STH) Q7R polymorphism has been reported to influence the individual's susceptibility to Alzheimer's disease (AD); however, conclusions remain controversial. Therefore, we performed this meta-analysis to explore the association between STH Q7R polymorphism and AD risk. Systematic literature searches were performed in the PubMed, Embase, Cochrane Library and Web of Science for studies published before 31 August 2016. Pooled odds ratios (ORs) and 95% confidence intervals (CIs) were calculated to assess the strength of the association using a fixed- or random-effects model. Subgroup analyses, Galbraith plot and sensitivity analyses were also performed. All statistical analyses were performed with STATA Version 12.0. A total of 19 case-control studies from 17 publications with 4387 cases and 3972 controls were included in our meta-analysis. The results showed that the Q7R polymorphism was significantly associated with an increased risk of AD in a recessive model (RR versus QQ+QR, OR = 1.27, 95% CI = 1.01-1.60, P = 0.040). After excluding the four studies not carried out in caucasians, the overall association was unchanged in all comparison models. Further subgroup analyses stratified by the time of AD onset, and the quality of included studies provided statistical evidence of significant increased risk of AD in RR versus QQ+QR model only in late-onset subjects (OR = 1.56, 95% CI = 1.07-2.26, P = 0.021) and in studies with high quality (OR = 1.37, 95% CI = 1.01-1.86, P = 0.043). This meta-analysis suggests that the RR genotype in saitohin Q7R polymorphism may be a human-specific risk factor for AD, especially among late-onset AD subjects and caucasian populations. © 2017 The Authors. Journal of Cellular and Molecular Medicine published by John Wiley & Sons Ltd and Foundation for Cellular and Molecular Medicine.

  7. An integrated quality function deployment and capital budgeting methodology for occupational safety and health as a systems thinking approach: the case of the construction industry.

    PubMed

    Bas, Esra

    2014-07-01

    In this paper, an integrated methodology for Quality Function Deployment (QFD) and a 0-1 knapsack model is proposed for occupational safety and health as a systems thinking approach. The House of Quality (HoQ) in QFD methodology is a systematic tool to consider the inter-relationships between two factors. In this paper, three HoQs are used to consider the interrelationships between tasks and hazards, hazards and events, and events and preventive/protective measures. The final priority weights of events are defined by considering their project-specific preliminary weights, probability of occurrence, and effects on the victim and the company. The priority weights of the preventive/protective measures obtained in the last HoQ are fed into a 0-1 knapsack model for the investment decision. Then, the selected preventive/protective measures can be adapted to the task design. The proposed step-by-step methodology can be applied to any stage of a project to design the workplace for occupational safety and health, and continuous improvement for safety is endorsed by the closed loop characteristic of the integrated methodology. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. High quality-factor quartz tuning fork glass probe used in tapping mode atomic force microscopy for surface profile measurement

    NASA Astrophysics Data System (ADS)

    Chen, Yuan-Liu; Xu, Yanhao; Shimizu, Yuki; Matsukuma, Hiraku; Gao, Wei

    2018-06-01

    This paper presents a high quality-factor (Q-factor) quartz tuning fork (QTF) with a glass probe attached, used in frequency modulation tapping mode atomic force microscopy (AFM) for the surface profile metrology of micro and nanostructures. Unlike conventionally used QTFs, which have tungsten or platinum probes for tapping mode AFM, and suffer from a low Q-factor influenced by the relatively large mass of the probe, the glass probe, which has a lower density, increases the Q-factor of the QTF probe unit allowing it to obtain better measurement sensitivity. In addition, the process of attaching the probe to the QTF with epoxy resin, which is necessary for tapping mode AFM, is also optimized to further improve the Q-factor of the QTF glass probe. The Q-factor of the optimized QTF glass probe unit is demonstrated to be very close to that of a bare QTF without a probe attached. To verify the effectiveness and the advantages of the optimized QTF glass probe unit, the probe unit is integrated into a home-built tapping mode AFM for conducting surface profile measurements of micro and nanostructures. A blazed grating with fine tool marks of 100 nm, a microprism sheet with a vertical amplitude of 25 µm and a Fresnel lens with a steep slope of 90 degrees are used as measurement specimens. From the measurement results, it is demonstrated that the optimized QTF glass probe unit can achieve higher sensitivity as well as better stability than conventional probes in the measurement of micro and nanostructures.

  9. $$B\\to Kl^+l^-$$ decay form factors from three-flavor lattice QCD

    DOE PAGES

    Bailey, Jon A.

    2016-01-27

    We compute the form factors for the B → Kl +l - semileptonic decay process in lattice QCD using gauge-field ensembles with 2+1 flavors of sea quark, generated by the MILC Collaboration. The ensembles span lattice spacings from 0.12 to 0.045 fm and have multiple sea-quark masses to help control the chiral extrapolation. The asqtad improved staggered action is used for the light valence and sea quarks, and the clover action with the Fermilab interpretation is used for the heavy b quark. We present results for the form factors f+(q 2), f 0(q 2), and f T(q 2), where q 2more » is the momentum transfer, together with a comprehensive examination of systematic errors. Lattice QCD determines the form factors for a limited range of q 2, and we use the model-independent z expansion to cover the whole kinematically allowed range. We present our final form-factor results as coefficients of the z expansion and the correlations between them, where the errors on the coefficients include statistical and all systematic uncertainties. Lastly, we use this complete description of the form factors to test QCD predictions of the form factors at high and low q 2.« less

  10. Characterization of Mid-Infrared Single Mode Fibers as Modal Filters

    NASA Technical Reports Server (NTRS)

    Ksendzov, A.; Lay, O.; Martin, S.; Sanghera, J. S.; Busse, L. E.; Kim, W. H.; Pureza, P. C.; Nguyen, V. Q.; Aggarwal, I. D.

    2007-01-01

    We present a technique for measuring the modal filtering ability of single mode fibers. The ideal modal filter rejects all input field components that have no overlap with the fundamental mode of the filter and does not attenuate the fundamental mode. We define the quality of a nonideal modal filter Q(sub f) as the ratio of transmittance for the fundamental mode to the transmittance for an input field that has no overlap with the fundamental mode. We demonstrate the technique on a 20 cm long mid-infrared fiber that was produced by the U.S. Naval Research Laboratory. The filter quality Q(sub f) for this fiber at 10.5 micron wavelength is 1000 +/- 300. The absorption and scattering losses in the fundamental mode are approximately 8 dB/m. The total transmittance for the fundamental mode, including Fresnel reflections, is 0.428 +/- 0.002. The application of interest is the search for extrasolar Earthlike planets using nulling interferometry. It requires high rejection ratios to suppress the light of a bright star, so that the faint planet becomes visible. The use of modal filters increases the rejection ratio (or, equivalently, relaxes requirements on the wavefront quality) by reducing the sensitivity to small wavefront errors. We show theoretically that, exclusive of coupling losses, the use of a modal filter leads to the improvement of the rejection ratio in a two-beam interferometer by a factor of Q(sub f).

  11. Voice Quality Modelling for Expressive Speech Synthesis

    PubMed Central

    Socoró, Joan Claudi

    2014-01-01

    This paper presents the perceptual experiments that were carried out in order to validate the methodology of transforming expressive speech styles using voice quality (VoQ) parameters modelling, along with the well-known prosody (F 0, duration, and energy), from a neutral style into a number of expressive ones. The main goal was to validate the usefulness of VoQ in the enhancement of expressive synthetic speech in terms of speech quality and style identification. A harmonic plus noise model (HNM) was used to modify VoQ and prosodic parameters that were extracted from an expressive speech corpus. Perception test results indicated the improvement of obtained expressive speech styles using VoQ modelling along with prosodic characteristics. PMID:24587738

  12. High-temperature superconducting radiofrequency probe for magnetic resonance imaging applications operated below ambient pressure in a simple liquid-nitrogen cryostat

    NASA Astrophysics Data System (ADS)

    Lambert, Simon; Ginefri, Jean-Christophe; Poirier-Quinot, Marie; Darrasse, Luc

    2013-05-01

    The present work investigates the joined effects of temperature and static magnetic field on the electrical properties of a 64 MHz planar high-temperature superconducting (HTS) coil, in order to enhance the signal-to-noise ratio (SNR) in nuclear magnetic resonance (NMR) applications with a moderate decrease of the HTS coil temperature (THTS). Temperature control is provided with accuracy better than 0.1 K from 80 to 66 K by regulating the pressure of the liquid nitrogen bath of a dedicated cryostat. The actual temperature of the HTS coil is obtained using a straightforward wireless method that eliminates the risks of coupling electromagnetic interference to the HTS coil and of disturbing the static magnetic field by DC currents near the region of interest. The resonance frequency ( f0) and the quality factor (Q) of the HTS coil are measured as a function of temperature in the 0-4.7 T field range with parallel and orthogonal orientations relative to the coil plane. The intrinsic HTS coil sensitivity and the detuning effect are then analyzed from the Q and f0 data. In the presence of the static magnetic field, the initial value of f0 in Earth's field could be entirely recovered by decreasing THTS, except for the orthogonal orientation above 1 T. The improvement of Q by lowering THTS was substantial. From 80 to 66 K, Q was multiplied by a factor of 6 at 1.5 T in orthogonal orientation. In parallel orientation, the maximum measured improvement of Q from 80 K to 66 K was a factor of 2. From 80 to 66 K, the improvement of the RF sensitivity relative to the initial value at the Earth's field and ambient pressure was up to 4.4 dB in parallel orientation. It was even more important in orthogonal orientation and continued to increase, up to 8.4 dB, at the maximum explored field of 1.5 T. Assuming that the noise contributions from the RF receiver are negligible, the SNR improvement using enhanced HTS coil cooling in NMR experiments was extracted from Q measurements either with or without the presence of the sample. Notably, the additional cooling in the presence of conductive samples appears more beneficial at higher field strengths and with an orthogonal incidence than with parallel. The temperature range accessible here, involving a relatively straightforward cryogenic design, brings a gain in RF sensitivity that is of great significance to cutting-edge applications with very weakly conducting samples, small biological specimens, or small animals in vivo. This work also demonstrates a better tolerance to thin-film orientation misalignments relative to the magnetic field, and this could eventually play a role in designing effective non-planar HTS coils or coil arrays which include elements of various orientations. Finally, the data provided in this work may help understand some critical aspects in the design of HTS coils for NMR and MRI applications and accounts for the presence of the static magnetic field, particularly regarding the SNR loss due to a decreased quality factor and detuning issues.

  13. The Vespid Allergy Quality of Life Questionnaire - cultural adaptation and translation to Portuguese.

    PubMed

    Silva, D; Pereira, A M; Santos, N; Amaral, L; Delgado, L; Oude Elberink, J N; Coimbra, A

    2017-05-01

    A cross-cultural translation of the Vespid Allergy Quality of Life Questionnaire (VQLQ) to the Portuguese population (VQLQ-P) was performed, assessing its applicability in wasp and in non-beekeeper bee venom allergic patients. Additionally, we evaluated a Visual Analogue Scale (VAS) to estimate hymenoptera allergy interference with daily life. Methods. Cross-cultural translation was performed according to recommendations. The final VQLQ-P version, the Expectation of Outcome questionnaire (EoQ), EQ-5D and VAS were applied to wasp (n = 19) and non-beekeeper bee venom allergic patients (n = 30). Results. VQLQ-P significantly correlated with EoQ, (r = 0.76, p < 0.01), EQ-5D (usual activities and anxiety / depression dimensions) and VAS, with a good internal consistency (Cronbach α = 0.88) in wasp allergic individuals. VQLQ-P and EoQ correlation was also high (r = 0.67, p < 0.01) in bee allergy. Conclusion. The VQLQ-P is a valuable tool to evaluate quality of life impairment in Portuguese hymenoptera venom allergic individuals.

  14. Health-related Quality of Life in Children With Prune-belly Syndrome and Their Caregivers.

    PubMed

    Arlen, Angela M; Kirsch, Susan S; Seidel, Natan E; Garcia-Roig, Michael; Smith, Edwin A; Kirsch, Andrew J

    2016-01-01

    To compare health-related quality of life (HRQoL) in children with prune-belly syndrome (PBS) and their caregivers to healthy controls, as children and adolescents with PBS face numerous potential physical and psychosocial challenges. Study participants completed the Pediatric Quality of Life Inventory Generic Core Scales (PedsQL) 4.0 generic core scales (children) or Quality of Life Enjoyment and Satisfaction Questionnaire Short Form (Q-LES-Q-SF) (caregivers) in an online, anonymous format. The PedsQL 4.0 is a 23-item, age-adjusted, validated questionnaire that assesses physical, emotional, social, and school functioning in pediatric patients. The Q-LES-Q-SF is a validated, self-report measure that assesses various areas of daily functioning in adults. PedsQL 4.0 was completed by 32 children with PBS. Individual physical (66.3 ± 20 vs 84.4 ± 17.3; P < .0001), emotional (68.4 ± 23.4 vs 80.9 ± 19.6; P < .01), social (63.1 ± 21.3 vs 87.4 ± 17.2; P  <  .0001), and school (53 ± 21.7 vs 78.6 ± 20.5; P < .0001) functioning scales were all significantly lower than in healthy children. Nineteen caregivers completed the Q-LES-Q-SF. Caregivers had a mean raw score of 54.8 ± 9.6, which was significantly lower (P  =  .02) than the comparative healthy adult cohort (59.8 ± 11.3). PBS profoundly impacts HRQoL in children, negatively affecting physical, emotional, social, and school functioning. Caregivers of PBS patients also report an overall lower quality of life, highlighting the challenges that families with chronically ill children often face. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Ultra-High Q Acoustic Resonance in Superfluid ^4He

    NASA Astrophysics Data System (ADS)

    De Lorenzo, L. A.; Schwab, K. C.

    2017-02-01

    We report the measurement of the acoustic quality factor of a gram-scale, kilohertz-frequency superfluid resonator, detected through the parametric coupling to a superconducting niobium microwave cavity. For temperatures between 400 mK and 50 mK, we observe a T^{-4} temperature dependence of the quality factor, consistent with a 3-phonon dissipation mechanism. We observe Q factors up to 1.4× 10^8, consistent with the dissipation due to dilute ^3He impurities, and expect that significant further improvements are possible. These experiments are relevant to exploring quantum behavior and decoherence of massive macroscopic objects, the laboratory detection of continuous gravitational waves from pulsars, and the probing of possible limits to physical length scales.

  16. Pretreatment with coenzyme Q10 improves ovarian response and embryo quality in low-prognosis young women with decreased ovarian reserve: a randomized controlled trial.

    PubMed

    Xu, Yangying; Nisenblat, Victoria; Lu, Cuiling; Li, Rong; Qiao, Jie; Zhen, Xiumei; Wang, Shuyu

    2018-03-27

    Management of women with reduced ovarian reserve or poor ovarian response (POR) to stimulation is one of the major challenges in reproductive medicine. The primary causes of POR remain elusive and oxidative stress was proposed as one of the important contributors. It has been suggested that focus on the specific subpopulations within heterogeneous group of poor responders could assist in evaluating optimal management strategies for these patients. This study investigated the effect of anti-oxidant treatment with coenzyme Q10 (CoQ10) on ovarian response and embryo quality in young low-prognosis patients with POR. This prospective, randomized controlled study included 186 consecutive patients with POR stratified according to the POSEIDON classification group 3 (age < 35, poor ovarian reserve parameters). The participants were randomized to the CoQ10 pre-treatment for 60 days preceding IVF-ICSI cycle or no pre-treatment. The number of high quality embryos was a primary outcome measure. A total of 169 participants were evaluated (76 treated with CoQ10 and 93 controls); 17 women were excluded due to low compliance with CoQ10 administration. The baseline demographic and clinical characteristics were comparable between the groups. CoQ10 pretreatment resulted in significantly lower gonadotrophin requirements and higher peak E2 levels. Women in CoQ10 group had increased number of retrieved oocytes (4, IQR 2-5), higher fertilization rate (67.49%) and more high-quality embryos (1, IQR 0-2); p < 0.05. Significantly less women treated with CoQ10 had cancelled embryo transfer because of poor embryo development than controls (8.33% vs. 22.89%, p = 0.04) and more women from treatment group had available cryopreserved embryos (18.42% vs. 4.3%, p = 0.012). The clinical pregnancy and live birth rates per embryo transfer and per one complete stimulation cycle tended to be higher in CoQ10 group but did not achieve statistical significance. Pretreatment with CoQ10 improves ovarian response to stimulation and embryological parameters in young women with poor ovarian reserve in IVF-ICSI cycles. Further work is required to determine whether there is an effect on clinical treatment endpoints.

  17. Studies on the Electrical Properties of Graphene Oxide-Reinforced Poly (4-Styrene Sulfonic Acid) and Polyvinyl Alcohol Blend Composites

    NASA Astrophysics Data System (ADS)

    Deshmukh, Kalim; Sankaran, Sowmya; Basheer Ahamed, M.; Khadheer Pasha, S. K.; Sadasivuni, Kishor Kumar; Ponnamma, Deepalekshmi; Al-Ali Almaadeed, Mariam; Chidambaram, K.

    In the present study, graphene oxide (GO)-reinforced poly (4-styrenesulfonic acid) (PSSA)/polyvinyl alcohol (PVA) blend composite films were prepared using colloidal blending technique at various concentrations of GO (0-3wt.%). The morphological investigations of the prepared composites were carried out using polarized optical microscopy and scanning electron microscopy. The electrical properties of composites were evaluated using an impedance analyzer in the frequency range 50Hz to 20MHz and temperature in the range 40-150∘C. Morphological studies infer that GO was homogeneously dispersed in the PSSA/PVA blend matrix. Investigations of electrical property indicate that the incorporation of GO into PSSA/PVA blend matrix resulted in the enhancement of the impedance (Z) and the quality factor (Q-factor) values. A maximum impedance of about 4.32×106Ω was observed at 50Hz and 90∘C for PSSA/PVA/GO composites with 3wt.% GO loading. The Q-factor also increased from 8.37 for PSSA/PVA blend to 59.8 for PSSA/PVA/GO composites with 3wt.% GO loading. These results indicate that PSSA/PVA/GO composites can be used for high-Q capacitor applications.

  18. Ultra-wideband microwave photonic filter with a high Q-factor using a semiconductor optical amplifier.

    PubMed

    Chen, Han

    2017-04-01

    An ultra-wideband microwave photonic filter (MPF) with a high quality (Q)-factor based on the birefringence effects in a semiconductor optical amplifier (SOA) is presented, and the theoretical fundamentals of the design are explained. The proposed MPF along orthogonal polarization in an active loop operates at up to a Ku-band and provides a tunable free spectral range from 15.44 to 19.44 GHz by controlling the SOA injection current. A prototype of the equivalent second-order infinite impulse response filter with a Q-factor over 6300 and a rejection ration exceeding 41 dB is experimentally demonstrated.

  19. Attenuation Characteristics of the Armutlu Peninsula (NW Turkey) Using Coda Q

    NASA Astrophysics Data System (ADS)

    Yavuz, Evrim; Çaka, Deniz; Tunç, Berna; Woith, Heiko; Gottfried Lühr, Birger; Barış, Şerif

    2016-04-01

    Attenuation characteristic of seismic waves was determined using coda Q in the frame of MARsite (MARsite has received funding from the European Union's Seventh Programme for research, technological development and demonstration under grant agreement No 308417). Data from 82 earthquakes recorded in 2013-2014 in the Armutlu Peninsula and its vicinity by 9 ARNET seismic stations were used for processing. The earthquake magnitudes (Ml) and depths vary from 1.5 to 3.7 and 1.2-16.9 km, respectively. Epicentral distances closer than 90 km were selected to ensure better signal-to-noise ratios. Lapse times between 20 seconds and 40 seconds at intervals of 5 seconds were used for the calculation of the coda wave quality factor. The coda windows were filtered at central frequencies of 1.5, 3, 6, 9 and 12 Hz bandpass filter. To obtain reliable results, only data with signal-to-noise ratios greater than 5 and correlation coefficents higher than 0.7 were used. The SEISAN software and one of its subroutines (CODAQ) were used for data processing and analyses. In the whole study area, Qc=(51±4)f^(0.91±0.04) for 20 seconds, Qc=(77±7)f^(0.80±0.04) for 30 seconds and Qc=(112±13)f^(0.72±0.06) for 40 seconds lapse times are obtained for coda wave quality factor. The observed quality factor is dependent on frequency and lapse time. The results indicate that the upper lithosphere is more heterogeneous and seismically more active than the lower lithosphere as expected in the region which is tectonically complex refering to the effects of the North Anatolian Fault Zone. By considering earthquake clusters and recorded stations, the scattering area was drawn. The intersection of the scattered areas for 20 seconds lapse time is covering all stations. Quality factor in 1 Hz and frequency dependent values were calculated separately and for the intersection of all scattered areas. Calculated Qo and n values of the intersection area are 50 and 0.89, respectively. Hence, the Qo and n values which are calculated using all stations and both values of the intersection area are very close to each other. Additionally, in the detailed review of TRML station which located in Yalova Province Termal District; Qc=(46±3)f^(0.97±0.04) for 20 seconds, Qc=(61±6)f^(1.03±0.06), for 30 seconds and Qc=(74±6)f^(1.06±0.05) for 40 seconds lapse times are obtained for coda wave quality factor. With these results, both the lower Qo values increasing with lapse times demonstrate high tectonic activity. Furthermore, the increasing n value with lapse times is conformable with the geothermal sources, next to the TRML station.

  20. The Effect of Viscous Air Damping on an Optically Actuated Multilayer MoS2 Nanomechanical Resonator Using Fabry-Perot Interference

    PubMed Central

    She, Yumei; Li, Cheng; Lan, Tian; Peng, Xiaobin; Liu, Qianwen; Fan, Shangchun

    2016-01-01

    We demonstrated a multilayer molybdenum disulfide (MoS2) nanomechanical resonator by using optical Fabry-Perot (F-P) interferometric excitation and detection. The thin circular MoS2 nanomembrane with an approximate 8-nm thickness was transferred onto the endface of a ferrule with an inner diameter of 125 μm, which created a low finesse F-P interferometer with a cavity length of 39.92 μm. The effects of temperature and viscous air damping on resonance behavior of the resonator were investigated in the range of −10–80 °C. Along with the optomechanical behavior of the resonator in air, the measured resonance frequencies ranged from 36 kHz to 73 kHz with an extremely low inflection point at 20 °C, which conformed reasonably to those solved by previously obtained thermal expansion coefficients of MoS2. Further, a maximum quality (Q) factor of 1.35 for the resonator was observed at 0 °C due to viscous dissipation, in relation to the lower Knudsen number of 0.0025~0.0034 in the tested temperature range. Moreover, measurements of Q factor revealed little dependence of Q on resonance frequency and temperature. These measurements shed light on the mechanisms behind viscous air damping in MoS2, graphene, and other 2D resonators. PMID:28335290

  1. Mid-infrared ultra-high-Q resonators based on fluoride crystalline materials

    NASA Astrophysics Data System (ADS)

    Lecaplain, C.; Javerzac-Galy, C.; Gorodetsky, M. L.; Kippenberg, T. J.

    2016-11-01

    The unavailability of highly transparent materials in the mid-infrared has been the main limitation in the development of ultra-sensitive molecular sensors or cavity-based spectroscopy applications. Whispering gallery mode microresonators have attained ultra-high-quality (Q) factor resonances in the near-infrared and visible. Here we report ultra-high Q factors in the mid-infrared using polished alkaline earth metal fluoride crystals. Using an uncoated chalcogenide tapered fibre as a high-ideality coupler in the mid-infrared, we study via cavity ringdown technique the losses of BaF2, CaF2, MgF2 and SrF2 microresonators. We show that MgF2 is limited by multiphonon absorption by studying the temperature dependence of the Q factor. In contrast, in SrF2 and BaF2 the lower multiphonon absorption leads to ultra-high Q factors at 4.5 μm. These values correspond to an optical finesse of , the highest value achieved for any type of mid-infrared resonator to date.

  2. Mid-infrared ultra-high-Q resonators based on fluoride crystalline materials

    PubMed Central

    Lecaplain, C.; Javerzac-Galy, C.; Gorodetsky, M. L.; Kippenberg, T. J.

    2016-01-01

    The unavailability of highly transparent materials in the mid-infrared has been the main limitation in the development of ultra-sensitive molecular sensors or cavity-based spectroscopy applications. Whispering gallery mode microresonators have attained ultra-high-quality (Q) factor resonances in the near-infrared and visible. Here we report ultra-high Q factors in the mid-infrared using polished alkaline earth metal fluoride crystals. Using an uncoated chalcogenide tapered fibre as a high-ideality coupler in the mid-infrared, we study via cavity ringdown technique the losses of BaF2, CaF2, MgF2 and SrF2 microresonators. We show that MgF2 is limited by multiphonon absorption by studying the temperature dependence of the Q factor. In contrast, in SrF2 and BaF2 the lower multiphonon absorption leads to ultra-high Q factors at 4.5 μm. These values correspond to an optical finesse of , the highest value achieved for any type of mid-infrared resonator to date. PMID:27869119

  3. Mid-infrared ultra-high-Q resonators based on fluoride crystalline materials.

    PubMed

    Lecaplain, C; Javerzac-Galy, C; Gorodetsky, M L; Kippenberg, T J

    2016-11-21

    The unavailability of highly transparent materials in the mid-infrared has been the main limitation in the development of ultra-sensitive molecular sensors or cavity-based spectroscopy applications. Whispering gallery mode microresonators have attained ultra-high-quality (Q) factor resonances in the near-infrared and visible. Here we report ultra-high Q factors in the mid-infrared using polished alkaline earth metal fluoride crystals. Using an uncoated chalcogenide tapered fibre as a high-ideality coupler in the mid-infrared, we study via cavity ringdown technique the losses of BaF 2 , CaF 2 , MgF 2 and SrF 2 microresonators. We show that MgF 2 is limited by multiphonon absorption by studying the temperature dependence of the Q factor. In contrast, in SrF 2 and BaF 2 the lower multiphonon absorption leads to ultra-high Q factors at 4.5 μm. These values correspond to an optical finesse of , the highest value achieved for any type of mid-infrared resonator to date.

  4. The analysis of corneal asphericity (Q value) and its related factors of 1,683 Chinese eyes older than 30 years.

    PubMed

    Xiong, Ying; Li, Jing; Wang, Ningli; Liu, Xue; Wang, Zhao; Tsai, Frank F; Wan, Xiuhua

    2017-01-01

    To determine corneal Q value and its related factors in Chinese subjects older than 30 years. Cross sectional study. 1,683 participants (1,683 eyes) from the Handan Eye Study were involved, including 955 female and 728 male with average age of 53.64 years old (range from 30 to 107 years). The corneal Q values of anterior and posterior surfaces were measured at 3.0, 5.0 and 7.0mm aperture diameters using Bausch & Lomb Orbscan IIz (software version 3.12). Age, gender and refractive power were recorded. The average Q values of the anterior surface at 3.0, 5.0 and 7.0mm aperture diameters were -0.28±0.18, -0.28±0.18, and -0.29±0.18, respectively. The average Q value of the anterior surface at the 5.0mm aperture diameter was negatively correlated with age (B = -0.003, p<0.01) and the refractive power (B = -0.013, p = 0.016). The average Q values of the posterior surface at 3.0, 5.0, and 7.0mm were -0.26±0.216, -0.26±0.214, and -0.26±0.215, respectively. The average Q value of the posterior surface at the 5.0mm aperture diameter was positively correlated with age (B = 0.002, p = 0.036) and the refractive power (B = 0.016, p = 0.043). The corneal Q value of the elderly Chinese subjects is different from that of previously reported European and American subjects, and the Q value appears to be correlated with age and refractive power.

  5. Porcine NAMPT gene: search for polymorphism, mapping and association studies.

    PubMed

    Cepica, S; Bartenschlager, H; Ovilo, C; Zrůstová, J; Masopust, M; Fernández, A; López, A; Knoll, A; Rohrer, G A; Snelling, W M; Geldermann, H

    2010-12-01

    NAMPT encodes an enzyme catalysing the rate-limiting step in NAD biosynthesis. The extracellular form of the enzyme is known as adipokine visfatin. We detected SNP AM999341:g.669T>C (referred to as 669T>C) in intron 9 and SNP FN392209:g.358A>G (referred to as 358A>G) in the promoter of the gene. RH mapping linked the gene to microsatellite SW944. Linkage analysis placed the gene on the current USDA – USMARC linkage map at position 92 cM on SSC9. Association analyses were performed in a wild boar × Meishan F2 family (W × M), with 45 traits recorded (growth and fattening, fat deposition, muscling, meat quality, stress resistance and other traits), and in a commercial Landrace × Chinese-European (LCE) synthetic population with records for 15 traits (growth, fat deposition, muscling, intramuscular fat, meat colour and backfat fatty acid content). In the W × M, SNP 669T>C was associated with muscling, fat deposition, growth and fattening, meat quality and other traits and in the LCE with muscling, meat quality and backfat fatty acid composition. In the W × M, SNP 358A>G was associated with muscling, fat deposition, growth and other traits. After correction for multiple testing, the NAMPT haplotypes were associated in the W × M with, in descending order, muscling (q = 0.0056), growth (q = 0.0056), fat deposition (q = 0.0109), fat-to-meat ratio (q = 0.0135), cooling losses (q = 0.0568) and longissimus pHU (q = 0.0695). The SNPs are hypothesized to be in linkage disequilibrium with a causative mutation affecting energy metabolism as a whole rather than fat metabolism alone.

  6. Assessment of ionization chamber correction factors in photon beams using a time saving strategy with PENELOPE code.

    PubMed

    Reis, C Q M; Nicolucci, P

    2016-02-01

    The purpose of this study was to investigate Monte Carlo-based perturbation and beam quality correction factors for ionization chambers in photon beams using a saving time strategy with PENELOPE code. Simulations for calculating absorbed doses to water using full spectra of photon beams impinging the whole water phantom and those using a phase-space file previously stored around the point of interest were performed and compared. The widely used NE2571 ionization chamber was modeled with PENELOPE using data from the literature in order to calculate absorbed doses to the air cavity of the chamber. Absorbed doses to water at reference depth were also calculated for providing the perturbation and beam quality correction factors for that chamber in high energy photon beams. Results obtained in this study show that simulations with phase-space files appropriately stored can be up to ten times shorter than using a full spectrum of photon beams in the input-file. Values of kQ and its components for the NE2571 ionization chamber showed good agreement with published values in the literature and are provided with typical statistical uncertainties of 0.2%. Comparisons to kQ values published in current dosimetry protocols such as the AAPM TG-51 and IAEA TRS-398 showed maximum percentage differences of 0.1% and 0.6% respectively. The proposed strategy presented a significant efficiency gain and can be applied for a variety of ionization chambers and clinical photon beams. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  7. Visual-Constructional Ability in Individuals with Severe Obesity: Rey Complex Figure Test Accuracy and the Q-Score.

    PubMed

    Sargénius, Hanna L; Bylsma, Frederick W; Lydersen, Stian; Hestad, Knut

    2017-01-01

    The aims of this study were to investigate visual-construction and organizational strategy among individuals with severe obesity, as measured by the Rey Complex Figure Test (RCFT), and to examine the validity of the Q-score as a measure for the quality of performance on the RCFT. Ninety-six non-demented morbidly obese (MO) patients and 100 healthy controls (HC) completed the RCFT. Their performance was calculated by applying the standard scoring criteria. The quality of the copying process was evaluated per the directions of the Q-score scoring system. Results revealed that the MO did not perform significantly lower than the HC on Copy accuracy (mean difference -0.302, CI -1.374 to 0.769, p = 0.579). In contrast, the groups did statistically differ from each other, with MO performing poorer than the HC on the Q-score (mean -1.784, CI -3.237 to -0.331, p = 0.016) and the Unit points (mean -1.409, CI -2.291 to -0.528, p = 0.002), but not on the Order points score (mean -0.351, CI -0.994 to 0.293, p = 0.284). Differences on the Unit score and the Q-score were slightly reduced when adjusting for gender, age, and education. This study presents evidence supporting the presence of inefficiency in visuospatial constructional ability among MO patients. We believe we have found an indication that the Q-score captures a wider range of cognitive processes that are not described by traditional scoring methods. Rather than considering accuracy and placement of the different elements only, the Q-score focuses more on how the subject has approached the task.

  8. The combination of high Q factor and chirality in twin cavities and microcavity chain

    PubMed Central

    Song, Qinghai; Zhang, Nan; Zhai, Huilin; Liu, Shuai; Gu, Zhiyuan; Wang, Kaiyang; Sun, Shang; Chen, Zhiwei; Li, Meng; Xiao, Shumin

    2014-01-01

    Chirality in microcavities has recently shown its bright future in optical sensing and microsized coherent light sources. The key parameters for such applications are the high quality (Q) factor and large chirality. However, the previous reported chiral resonances are either low Q modes or require very special cavity designs. Here we demonstrate a novel, robust, and general mechanism to obtain the chirality in circular cavity. By placing a circular cavity and a spiral cavity in proximity, we show that ultra-high Q factor, large chirality, and unidirectional output can be obtained simultaneously. The highest Q factors of the non-orthogonal mode pairs are almost the same as the ones in circular cavity. And the co-propagating directions of the non-orthogonal mode pairs can be reversed by tuning the mode coupling. This new mechanism for the combination of high Q factor and large chirality is found to be very robust to cavity size, refractive index, and the shape deformation, showing very nice fabrication tolerance. And it can be further extended to microcavity chain and microcavity plane. We believe that our research will shed light on the practical applications of chirality and microcavities. PMID:25262881

  9. Effect of Thickener and Gasoline Quality on the Properties of Napalm Fuels

    DTIC Science & Technology

    1945-01-01

    6 ’ So H S3 lOCDCCtDOnroO) )««0 0)<E«DO «Hf-IG)IQ|Q0l*-<OO«[> P"iS OOONQHC O «3 IO HHO ’ »O «TOO «XOHCOOilNHIOIOOOIOC- 1’ 01 CD...OOO0JC0O’OCDtf> Cpl0rHl0*OtQlGDtH£CUO>Q O^CUi-KO .O »tOO» »on feCDOl HH(«niQ9 »HHH(0 HHO « I l«KJB* ©HN«(Dlf^V®Ct

  10. Tunable dark modes in one-dimensional “diatomic” dielectric gratings

    DOE PAGES

    Zeng, Bo; Majumdar, Arka; Wang, Feng

    2015-05-04

    Recently researchers have demonstrated ultra high quality factor (Q) resonances in one-dimensional (1D) dielectric gratings. Here we theoretically investigate a new class of subwavelength 1D gratings, namely “diatomic” gratings with two nonequivalent subcells in one period, and utilize their intrinsic dark modes to achieve robust ultra high Q resonances. Such “diatomic” gratings provide extra design flexibility, and enable high Q resonators using thinner geometry with smaller filling factors compared to conventional designs like the high contrast gratings (HCGs). More importantly, we show that these high Q resonances can be efficiently tuned in situ, making the design appealing in various applicationsmore » including optical sensing, filtering and displays.« less

  11. MO-FG-CAMPUS-IeP1-05: New Ionization Chamber Dosimetry of Absorbed Dose to Water in Diagnostic KV X-Ray Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Araki, F; Ohno, T

    Purpose: To develop new ionization chamber dosimetry of absorbed dose to water in diagnostic kV x-ray beams, by using a beam quality conversion factor, kQ, for Co-60 to kV x-ray and an ionization conversion factor for a water-substitute plastic phantom. Methods: kQ was calculated for aluminum half value-layers (Al-HVLs) of 1.5 mm to 8 mm which were generated by kV x-ray beams of 50 to 120 kVp. Twenty-two energy spectra for ten effective energies (Eeff) were calculated by a SpecCalc program. Depth doses in water were calculated at 5 × 5 to 30 × 30 cm{sup 2} fields. Output factorsmore » were also obtained from the dose ratio for a 10 × 10 cm{sup 2} field. kQ was obtained for a PTW30013 Former ion chamber. In addition, an ionization conversion factor of the PWDT phantom to water was calculated. All calculations were performed with EGSnrc/cavity code and egs-chamber codes. Results: The x-ray beam energies for 1.5 mm to 8 mm Al-HVLs ranged in Eeff of 25.7 to 54.3 keV. kQ for 1.5 mm to 8 mm Al-HVLs were 0.831 to 0.897, at 1 and 2 cm depths for a 10 × 10 cm2 field. Similarly, output factors for 5 × 5 to 30 × 30 cm{sup 2} fields were 0.937 to 1.033 for 25.7 keV and 0.857 to 1.168 for 54.3 keV. The depth dose in a PWDT phantom decreased up to 5% compared to that in water at depth of ten percent of maximum dose for 1.5 mm Al-HVL. The ionization ratios of water/PWDT phantoms for the PTW30013 chamber were 1.012 to 1.007 for 1.5 mm to 8 mm Al-HVLs at 1 cm depth. Conclusion: It became possible to directly measure the absorbed dose to water with the ionization chamber in diagnostic kV x-ray beams, by using kQ and the PWDT phantom.« less

  12. Significant improvement in the thermal annealing process of optical resonators

    NASA Astrophysics Data System (ADS)

    Salzenstein, Patrice; Zarubin, Mikhail

    2017-05-01

    Thermal annealing performed during process improves the quality of the roughness of optical resonators reducing stresses at the periphery of their surface thus allowing higher Q-factors. After a preliminary realization, the design of the oven and the electronic method were significantly improved thanks to nichrome resistant alloy wires and chopped basalt fibers for thermal isolation during the annealing process. Q-factors can then be improved.

  13. Temperature Compensation of Aluminum Nitride Lamb Wave Resonators Utilizing the Lowest-Order Symmetric Mode

    DTIC Science & Technology

    2012-12-14

    PZT ceramic plate [40]. Since then Lamb wave devices utilizing the lowest-order antisymmetric (A0) mode propagation in ZnO thin plate were widely...Million Pt Platinum PVDF Polyvinylidene Flouride PZT Lead Zirconium Titanate Q Quality Factor R Resistor RIE Reactive Ion Etching Rm Motional...GaAs), silicon carbide (SiC), langasite (LGS), lead zirconium titanate ( PZT ), and polyvinylidene flouride (PVDF). Each piezoelectric material has

  14. Micropillars with a controlled number of site-controlled quantum dots

    NASA Astrophysics Data System (ADS)

    Kaganskiy, Arsenty; Gericke, Fabian; Heuser, Tobias; Heindel, Tobias; Porte, Xavier; Reitzenstein, Stephan

    2018-02-01

    We report on the realization of micropillars with site-controlled quantum dots (SCQDs) in the active layer. The SCQDs are grown via the buried stressor approach which allows for the positioned growth and device integration of a controllable number of QDs with high optical quality. This concept is very powerful as the number and the position of SCQDs in the cavity can be simultaneously controlled by the design of the buried-stressor. The fabricated micropillars exhibit a high degree of position control for the QDs above the buried stressor and Q-factors of up to 12 000 at an emission wavelength of around 930 nm. We experimentally analyze and numerically model the cavity Q-factor, the mode volume, the Purcell factor, and the photon-extraction efficiency as a function of the aperture diameter of the buried stressor. Exploiting these SCQD micropillars, we experimentally observe a Purcell enhancement in the single-QD regime with FP = 4.3 ± 0.3.

  15. Is the coexistence of sustained ST-segment elevation and abnormal Q waves a risk factor for electrical storm in implanted cardioverter defibrillator patients with structural heart diseases?

    PubMed

    Furushima, Hiroshi; Chinushi, Masaomi; Iijima, Kenichi; Hasegawa, Kanae; Sato, Akinori; Izumi, Daisuke; Watanabe, Hiroshi; Aizawa, Yoshifusa

    2012-05-01

    The aim of this study was to determine whether or not the coexistence of sustained ST-segment elevation and abnormal Q waves (STe-Q) could be a risk factor for electrical storm (ES) in implanted cardioverter defibrillator (ICD) patients with structural heart diseases. In all, 156 consecutive patients received ICD therapy for secondary prevention of sudden cardiac death and/or sustained ventricular tachyarrhythmias were included. Electrical storm was defined as ≥3 separate episodes of ventricular tachycardia (VT) and/or ventricular fibrillation (VF) terminated by ICD therapies within 24 h. During a mean follow-up of 1825 ± 1188 days, 42 (26.9%) patients experienced ES, of whom 12 had coronary artery disease, 15 had idiopathic dilated cardiomyopathy, 6 had hypertrophic cardiomyopathy, 4 had arrhythmogenic right ventricular cardiomyopathy, 4 had cardiac sarcoidosis, and 1 had valvular heart disease. Sustained ST-segment elevation and abnormal Q waves in ≥2 leads on the 12-lead electrocardiography was observed in 33 (21%) patients. On the Kaplan-Meier analysis, patients with STe-Q had a markedly higher risk of ES than those without STe-Q (P< 0.0001). The multivariate Cox proportional hazards regression model indicated that STe-Q and left ventricular ejection fraction (LVEF) (<30%) were independent risk factors associated with the recurrence of VT/VF (STe-Q: HR 1.962, 95% CI 1.24-3.12, P= 0.004; LVEF: HR 1.860, 95% CI 1.20-2.89, P= 0.006), and STe-Q was an independent risk factor associated with ES (HR 4.955, 95% CI 2.69-9.13, P< 0.0001). Sustained ST-segment elevation and abnormal Q waves could be a risk factor of not only recurrent VT/VF but also ES in patients with structural heart diseases.

  16. SU-G-TeP2-03: Comparison of Standard Dosimetry Protocol in Japan and AAPM TG-51 Addendum in Order to Establish Optimal Dosimetry for FFF Beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matsunaga, T; Adachi, Y; Hayashi, N

    Purpose: Japan Standard Dosimetry of Absorbed dose to water in external beam radiotherapy (JSDP12) is widely used to measure radiation dose in radiotherapy. However, JSDP12 does not take flattening-filter-free (FFF) beam into consideration. In addition, JSDP12 applied TPR20,10 for dose quality index for photon beam. The purpose of this study is to compare JSDP12 with AAPM TG-51 addendum in order to establish optimal dosimetry procedure for FFF beam. Method: We evaluated the ion-recombination factor (ks) and the correction factor of radial beam profile (Prp) in FFF beam dosimetry. The ks was introduced by 2 voltages method and verified by Jaffe’smore » plot. The Prp was given by both film measurement and calculation of treatment planning system, and compared them. Next, we compared the dose quality indexes (kQ) between TPR20,10 method and PDD(10)x method. Finally we considered optimal dosimetry protocol for FFF photon beam using JSDP12 with referring TG-51 addendum protocols. The FFF photon beams of 6 MV (6X-FFF) and 10 MV (10X-FFF) from TrueBeam were investigated in this study. Results: The ks for 6X-FFF and 10X-FFF beams were 1.005 and 1.010, respectively. The Prp of 0.6 cc ionization chamber for 6X-FFF and 10X-FFF beams (Film, TPS) were (1.004, 1.008) and (1.005, 1.008), respectively. The kQ for 6X-FFF and 10X-FFF beams (JSDP12, TG-51 addendum) were (0.9950, 0.9947) and (0.9851, 0.9845), respectively. The most effective factor for uncertainty in FFF photon beam measurement was Prp for JSDP12 formalism. Total dosimetric differences between JSDP12 and TG-51 addendum for 6X-FFF and 10X-FFF were -0.47% and -0.73%, respectively. Conclusion: The total dosimetric difference between JSDP12 and TG-51 addendum was within 1%. The introduction of kQ given by JSDP is feasible for FFF photon beam dosimetry. However, we think Prp should be considered for optimal dosimetry procedure even if JSDP12 is used for FFF photon beam dosimetry.« less

  17. Weighting factors for radiation quality: how to unite the two current concepts.

    PubMed

    Kellerer, Albrecht M

    2004-01-01

    The quality factor, Q(L), used to be the universal weighting factor to account for radiation quality, until--in its 1991 Recommendations--the ICRP established a dichotomy between 'computable' and 'measurable' quantities. The new concept of the radiation weighting factor, w(R), was introduced for use with the 'computable' quantities, such as the effective dose, E. At the same time, the application of Q(L) was restricted to 'measurable' quantities, such as the operational quantities ambient dose equivalent or personal dose equivalent. The result has been a dual system of incoherent dosimetric quantities. The most conspicuous inconsistency resulted for neutrons, for which the new concept of wR had been primarily designed. While its definition requires an accounting for the gamma rays produced by neutron capture in the human body, this effect is not adequately reflected in the numerical values of wR, which are now suitable for mice, but are--at energies of the incident neutrons below 1 MeV--conspicuously too large for man. A recent Report 92 to ICRP has developed a proposal to correct the current imbalance and to define a linkage between the concepts Q(L) and wR. The proposal is here considered within a broader assessment of the rationale that led to the current dual system of dosimetric quantities.

  18. SU-E-T-804: Verification of the BJR-25 Method of KQ Determination for CyberKnife Absolute Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gersh, J; Spectrum Medical Physics, LLC - Greenville, SC; Willett, B

    2015-06-15

    Purpose: Absolute calibration of the CyberKnife is performed using a 6cm-diameter cone defined at 80cm SAD. Since kQ is defined using PDD values determined using 10×10 cm fields at 100cm SSD, the PDD must be corrected in order to correctly apply the quality conversion factor. The accepted method is based on equivalent field-size conversions of PDD values using BJR25. Using the new InCise MLC system, the CK is capable of generating a rectangular field equivalent to 10×10 cm square field. In this study, a comparison is made between kQ values determined using the traditional BJR25 method and the MLC methodmore » introduced herein. Methods: First, kQ(BJR) is determined: a PDD is acquired using a 6cm circular field at 100cm SSD, its field size converted to an equivalent square, and PDD converted to a 10×10cm field using the appropriate BJR25 table. Maintaining a consistent setup, the collimator is changed, and the MLC method is used. Finally, kQ is determined using PDDs acquired with a 9.71×10.31cm at 100cm SSD. This field is produced by setting the field to a size of 7.77×8.25cm (since it is defined at 80cm SAD). An exact 10×10cm field since field size is relegated to increments of its leaf width (0.25cm). This comparison is made using an Exradin A1SL, IBA CC08, IBA CC13, and an Exradin A19. For each detector and collimator type, the beam injector was adjusted to give 5 different beam qualities; representing a range of clinical systems. Results: Averaging across all beam qualities, kQ(MLC) differed from kQ(BJR) by less than 0.15%. The difference between the values increased with detector volume. Conclusion: For CK users with standard cone collimators, the BJR25 method has been verified. For CK users the MLC system, a technique is described to determine kQ. Primary author is the President/Owner of Spectrum Medical Physics, LLC, a company which maintains contracts with Siemens Healthcare and Standard Imaging, Inc.« less

  19. Polymorphisms of the factor VII gene associated with the low activities of vitamin K-dependent coagulation factors in one-month-old infants.

    PubMed

    Ito, Koichi; Goto, Kenji; Sugiura, Tokio; Muramatsu, Kanji; Ando, Toshihiro; Maniwa, Hiroko; Yokoyama, Takao; Sugiyama, Kohachiro; Togari, Hajime

    2007-01-01

    Despite administration of vitamin K (VK), some infants show lower activity of VK-dependent coagulation factors and they could develop intracranial hemorrhage. For preventing VK deficiency bleeding (VKDB) in infants, oral administration of VK and a screening test for VK deficiency are carried out in Japan. For the screening, the total activity of VK-dependent coagulation factors is measured using a commercial product, Normotest. This study was undertaken to clarify the importance of the following genetic and environmental factors on the coagulation status in one-month-old infants: two polymorphisms in the factor VII gene, -323P0/10 (a 10-bp insertion in the promoter region at position -323) and R353Q (the replacement of arginine [R] with glutamine [Q] at residue 353) and sex, age, gestational age, birth weight, and feeding regimen. Two hundred Japanese infants (34.6 +/- 4.0 days old) were screened for VK-dependent coagulation activity with Normotest and were genotyped for the two polymorphisms. Among the subjects screened, 18 infants (9%) carried the P10 allele and 26 (13%) carried the R353Q allele. Multiple regression analysis showed that the 10-bp inserted (P10) allele or the Q allele was associated with the lower coagulation activities. The coagulation activities for the R/Q genotype were significantly lower than those for the R/R genotype and those for the P0/P10 genotype were significantly lower than those for the P0/P0 genotype. Therefore, infants who carry the P10 allele or the Q allele show lower activity of VK-dependent coagulation factors. These infants may have a higher risk of VKDB manifestation.

  20. Tunable Q-Factor RF Cavity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Balcazar, Mario D.; Yonehara, Katsuya; Moretti, Alfred

    Intense neutrino beam is a unique probe for researching beyond the standard model. Fermilab is the main institution to produce the most powerful and widespectrum neutrino beam. From that respective, a radiation robust beam diagnostic system is a critical element in order to maintain the quality of the neutrino beam. Within this context, a novel radiation-resistive beam profile monitor based on a gasfilled RF cavity is proposed. The goal of this measurement is to study a tunable Qfactor RF cavity to determine the accuracy of the RF signal as a function of the quality factor. Specifically, measurement error of themore » Q-factor in the RF calibration is investigated. Then, the RF system will be improved to minimize signal error.« less

  1. Switchable and tunable film bulk acoustic resonator fabricated using barium strontium titanate active layer and Ta{sub 2}O{sub 5}/SiO{sub 2} acoustic reflector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sbrockey, N. M., E-mail: sbrockey@structuredmaterials.com; Tompa, G. S.; Kalkur, T. S.

    2016-08-01

    A solidly mounted acoustic resonator was fabricated using a Ba{sub 0.60}Sr{sub 0.40}TiO{sub 3} (BST) film deposited by metal organic chemical vapor deposition. The device was acoustically isolated from the substrate using a Bragg reflector consisting of three pairs of Ta{sub 2}O{sub 5}/SiO{sub 2} layers deposited by chemical solution deposition. Transmission electron microscopy verified that the Bragg reflector was not affected by the high temperatures and oxidizing conditions necessary to process high quality BST films. Electrical characterization of the resonator demonstrated a quality factor (Q) of 320 and an electromechanical coupling coefficient (K{sub t}{sup 2}) of 7.0% at 11 V.

  2. A multifactorial evaluation of illness risk factors in athletes preparing for the Summer Olympic Games.

    PubMed

    Drew, Michael K; Vlahovich, Nicole; Hughes, David; Appaneal, Renee; Peterson, Kirsten; Burke, Louise; Lundy, Bronwen; Toomey, Mary; Watts, David; Lovell, Gregory; Praet, Stephan; Halson, Shona; Colbey, Candice; Manzanero, Silvia; Welvaert, Marijke; West, Nic; Pyne, David B; Waddington, Gordon

    2017-08-01

    Illness can disrupt training and competition performance of athletes. Few studies have quantified the relative contribution of the known medical, behavioural and lifestyle risk factors. Cross-sectional. Olympic athletes from 11 sports (n=221) were invited to complete questionnaires administered nine months before the Rio 2016 Olympic Games. These included the Depression, Anxiety and Stress Questionnaire (DASS-21), Perceived Stress Scale (PSS), Dispositional Resilience Scale (DRS), Recovery-Stress Questionnaire (REST-Q-52 item), Low Energy in Females Questionnaire (LEAF-Q), a modified Personal and Household Hygiene questionnaire, Epworth Sleepiness Scale, Pittsburgh Sleep Quality Index, and custom-made questionnaires on probiotic usage and travel. An illness (case) was defined as an event which limited training or competition for greater hours in the prior month. Odds ratios and attributable fractions in the population (AFP) were utilised for categorical variables with independent t-tests or Wilcoxon rank-sum for continuous variables. Eighty-one athletes responded (male, n=26; female, n=55). There were 16 illness cases and 65 controls. Female athletes were at higher odds of illness (OR=9.4, 95%CI 1.3-410, p=0.01, AFP=0.84). Low energy availability (LEAF-Q score ≥8: OR=7.4, 95%CI 0.78-352, p=0.04, AFP=0.76), depression symptoms (DASS-21: depression score >4, OR=8.4, 95%CI 1.1-59, p<0.01; AFP=0.39) and higher perceived stress (PSS: 10-item, p=0.04) were significantly associated with illness. Female sex, low energy availability, and mental health are associated with sports incapacity (time loss) due to illness. Low energy availability had high attributable fractions in the population and stands out as a primary association with illness. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  3. Development and Validation of an Instrument for Measuring the Quality of Teamwork in Teaching Teams in Postgraduate Medical Training (TeamQ)

    PubMed Central

    Slootweg, Irene A.; Lombarts, Kiki M. J. M. H.; Boerebach, Benjamin C. M.; Heineman, Maas Jan; Scherpbier, Albert J. J. A.; van der Vleuten, Cees P. M.

    2014-01-01

    Background Teamwork between clinical teachers is a challenge in postgraduate medical training. Although there are several instruments available for measuring teamwork in health care, none of them are appropriate for teaching teams. The aim of this study is to develop an instrument (TeamQ) for measuring teamwork, to investigate its psychometric properties and to explore how clinical teachers assess their teamwork. Method To select the items to be included in the TeamQ questionnaire, we conducted a content validation in 2011, using a Delphi procedure in which 40 experts were invited. Next, for pilot testing the preliminary tool, 1446 clinical teachers from 116 teaching teams were requested to complete the TeamQ questionnaire. For data analyses we used statistical strategies: principal component analysis, internal consistency reliability coefficient, and the number of evaluations needed to obtain reliable estimates. Lastly, the median TeamQ scores were calculated for teams to explore the levels of teamwork. Results In total, 31 experts participated in the Delphi study. In total, 114 teams participated in the TeamQ pilot. The median team response was 7 evaluations per team. The principal component analysis revealed 11 factors; 8 were included. The reliability coefficients of the TeamQ scales ranged from 0.75 to 0.93. The generalizability analysis revealed that 5 to 7 evaluations were needed to obtain internal reliability coefficients of 0.70. In terms of teamwork, the clinical teachers scored residents' empowerment as the highest TeamQ scale and feedback culture as the area that would most benefit from improvement. Conclusions This study provides initial evidence of the validity of an instrument for measuring teamwork in teaching teams. The high response rates and the low number of evaluations needed for reliably measuring teamwork indicate that TeamQ is feasible for use by teaching teams. Future research could explore the effectiveness of feedback on teamwork in follow up measurements. PMID:25393006

  4. Development and validation of an instrument for measuring the quality of teamwork in teaching teams in postgraduate medical training (TeamQ).

    PubMed

    Slootweg, Irene A; Lombarts, Kiki M J M H; Boerebach, Benjamin C M; Heineman, Maas Jan; Scherpbier, Albert J J A; van der Vleuten, Cees P M

    2014-01-01

    Teamwork between clinical teachers is a challenge in postgraduate medical training. Although there are several instruments available for measuring teamwork in health care, none of them are appropriate for teaching teams. The aim of this study is to develop an instrument (TeamQ) for measuring teamwork, to investigate its psychometric properties and to explore how clinical teachers assess their teamwork. To select the items to be included in the TeamQ questionnaire, we conducted a content validation in 2011, using a Delphi procedure in which 40 experts were invited. Next, for pilot testing the preliminary tool, 1446 clinical teachers from 116 teaching teams were requested to complete the TeamQ questionnaire. For data analyses we used statistical strategies: principal component analysis, internal consistency reliability coefficient, and the number of evaluations needed to obtain reliable estimates. Lastly, the median TeamQ scores were calculated for teams to explore the levels of teamwork. In total, 31 experts participated in the Delphi study. In total, 114 teams participated in the TeamQ pilot. The median team response was 7 evaluations per team. The principal component analysis revealed 11 factors; 8 were included. The reliability coefficients of the TeamQ scales ranged from 0.75 to 0.93. The generalizability analysis revealed that 5 to 7 evaluations were needed to obtain internal reliability coefficients of 0.70. In terms of teamwork, the clinical teachers scored residents' empowerment as the highest TeamQ scale and feedback culture as the area that would most benefit from improvement. This study provides initial evidence of the validity of an instrument for measuring teamwork in teaching teams. The high response rates and the low number of evaluations needed for reliably measuring teamwork indicate that TeamQ is feasible for use by teaching teams. Future research could explore the effectiveness of feedback on teamwork in follow up measurements.

  5. Physical Activity and the Risk of Primary Hyperparathyroidism.

    PubMed

    Vaidya, Anand; Curhan, Gary C; Paik, Julie M; Wang, Molin; Taylor, Eric N

    2016-04-01

    Primary hyperparathyroidism (P-HPTH) is relatively common and predominantly affects women. Prior studies have shown that physical activity (PA) can lower PTH levels. Our objective was to evaluate the hypothesis that lower PA is a risk factor for developing P-HPTH. This prospective cohort study included 69 621 female participants in the Nurses' Health Study I followed for 22 years. PA and other dietary and demographic exposures were quantified via detailed, and validated, biennial questionnaires. Incident P-HPTH was confirmed by medical record review after initial assessment by questionnaire. Adjusted Cox proportional hazards models were used to evaluate whether PA was an independent risk factor for developing P-HPTH. We also evaluated the risk of developing P-HPTH when combining low PA (<16 metabolic equivalent hours/week) with a previously identified independent risk factor for developing P-HPTH: low calcium intake (<800 mg/day). The relation between PA and PTH levels was evaluated in 625 participants. We confirmed 302 incident cases of P-HPTH during 1 474 993 person-years of follow-up. Participants in the highest quintile (Q) of PA had a 50% lower risk of developing P-HPTH: age-adjusted relative risks and 95% confidence intervals for incident P-HPTH by lowest to highest of PA were Q1 = 1.0 (reference); Q2 = 0.83 (0.60–1.15); Q3 = 0.84 (0.61–1.15); Q4 = 0.50 (0.34–0.74); Q5 = 0.50 (0.35–0.73); P for trend <.001. Extensive multivariable adjustments did not materially change these findings. The adjusted relative risk for developing P-HPTH among participants with the combination lower PA and lower calcium intake was 2.37-fold (1.60–3.51) higher than in participants with higher PA and higher calcium intake. PA was inversely correlated with serum PTH (ρ = −0.09, P = .03); the mean adjusted serum PTH in Q 2–5 of PA was lower than in Q 1 (36.3 vs 39.1 pg/mL, P = .02). Low physical activity may be a modifiable risk factor for developing P-HPTH in women.

  6. Psychometric properties of the Belgian coach version of the coach-athlete relationship questionnaire (CART-Q).

    PubMed

    Balduck, A-L; Jowett, S

    2010-10-01

    The study examined the psychometric properties of the Belgian coach version of the Coach-Athlete Relationship Questionnaire (CART-Q). The questionnaire includes three dimensions (Closeness, Commitment, and Complementarity) in a model that intends to measure the quality of the coach-athlete relationship. Belgian coaches (n=144) of athletes who performed at various competition levels in such sports as football, basketball, and volleyball responded to the CART-Q and to the Leadership Scale for Sport (LSS). A confirmatory factor analysis proved to be slightly more satisfactory for a three-order factor model, compared with a hierarchical first-order factor model. The three factors showed acceptable internal consistency scores. Moreover, functional associations between the three factors and coach leadership behaviors were found offering support to the instrument's concurrent validity. The findings support previous validation studies and verify the psychometric properties of the CART-Q applied to Belgian coaches of team sports. © 2009 John Wiley & Sons A/S.

  7. SamSelect: a sample sequence selection algorithm for quorum planted motif search on large DNA datasets.

    PubMed

    Yu, Qiang; Wei, Dingbang; Huo, Hongwei

    2018-06-18

    Given a set of t n-length DNA sequences, q satisfying 0 < q ≤ 1, and l and d satisfying 0 ≤ d < l < n, the quorum planted motif search (qPMS) finds l-length strings that occur in at least qt input sequences with up to d mismatches and is mainly used to locate transcription factor binding sites in DNA sequences. Existing qPMS algorithms have been able to efficiently process small standard datasets (e.g., t = 20 and n = 600), but they are too time consuming to process large DNA datasets, such as ChIP-seq datasets that contain thousands of sequences or more. We analyze the effects of t and q on the time performance of qPMS algorithms and find that a large t or a small q causes a longer computation time. Based on this information, we improve the time performance of existing qPMS algorithms by selecting a sample sequence set D' with a small t and a large q from the large input dataset D and then executing qPMS algorithms on D'. A sample sequence selection algorithm named SamSelect is proposed. The experimental results on both simulated and real data show (1) that SamSelect can select D' efficiently and (2) that the qPMS algorithms executed on D' can find implanted or real motifs in a significantly shorter time than when executed on D. We improve the ability of existing qPMS algorithms to process large DNA datasets from the perspective of selecting high-quality sample sequence sets so that the qPMS algorithms can find motifs in a short time in the selected sample sequence set D', rather than take an unfeasibly long time to search the original sequence set D. Our motif discovery method is an approximate algorithm.

  8. Recent progress in opto-electronic oscillator

    NASA Technical Reports Server (NTRS)

    Maleki, Lute

    2005-01-01

    The optoelectronic oscillator (OEO) is a unique device based on photonics techniques to generate highly spectrally pure microwave signals [1]. The development of the OEO was motivated by the need for high performance oscillators in the frequency range larger than 10 GHz, where conventional electronic oscillators have a number of limitations. These limitations typically stem from the product of fQ, where f is the oscillator frequency and Q is the quality factor of the resonator in the oscillator. In conventional resonators, whether electromagnetic or piezoelectric, this product is usually a constant. Thus, as the oscillator frequency is pushed higher, the quality factor degrades, resulting in degradation of the phase noise of the oscillator. An approach to mitigate the problem is to start with a very high quality signal in the 5 to 100 MHz range generated by a quartz oscillator and multiply the frequency to achieve the desired microwave signal. Here again, frequency multiplication also results in an increase of the phase noise by a factor of 2010gN, where N is the multiplication factor.

  9. High-Q Wafer Level Package Based on Modified Tri-Layer Anodic Bonding and High Performance Getter and Its Evaluation for Micro Resonant Pressure Sensor.

    PubMed

    Wang, Liying; Du, Xiaohui; Wang, Lingyun; Xu, Zhanhao; Zhang, Chenying; Gu, Dandan

    2017-03-16

    In order to achieve and maintain a high quality factor (high-Q) for the micro resonant pressure sensor, this paper presents a new wafer level package by adopting cross-layer anodic bonding technique of the glass/silicon/silica (GSS) stackable structure and integrated Ti getter. A double-layer structure similar to a silicon-on-insulator (SOI) wafer is formed after the resonant layer and the pressure-sensitive layer are bonded by silicon direct bonding (SDB). In order to form good bonding quality between the pressure-sensitive layer and the glass cap layer, the cross-layer anodic bonding technique is proposed for vacuum package by sputtering Aluminum (Al) on the combination wafer of the pressure-sensitive layer and the resonant layer to achieve electrical interconnection. The model and the bonding effect of this technique are discussed. In addition, in order to enhance the performance of titanium (Ti) getter, the prepared and activation parameters of Ti getter under different sputtering conditions are optimized and discussed. Based on the optimized results, the Ti getter (thickness of 300 nm to 500 nm) is also deposited on the inside of the glass groove by magnetron sputtering to maintain stable quality factor (Q). The Q test of the built testing system shows that the number of resonators with a Q value of more than 10,000 accounts for more than 73% of the total. With an interval of 1.5 years, the Q value of the samples remains almost constant. It proves the proposed cross-layer anodic bonding and getter technique can realize high-Q resonant structure for long-term stable operation.

  10. Monte Carlo-based investigations on the impact of removing the flattening filter on beam quality specifiers for photon beam dosimetry.

    PubMed

    Czarnecki, Damian; Poppe, Björn; Zink, Klemens

    2017-06-01

    The impact of removing the flattening filter in clinical electron accelerators on the relationship between dosimetric quantities such as beam quality specifiers and the mean photon and electron energies of the photon radiation field was investigated by Monte Carlo simulations. The purpose of this work was to determine the uncertainties when using the well-known beam quality specifiers or energy-based beam specifiers as predictors of dosimetric photon field properties when removing the flattening filter. Monte Carlo simulations applying eight different linear accelerator head models with and without flattening filter were performed in order to generate realistic radiation sources and calculate field properties such as restricted mass collision stopping power ratios (L¯/ρ)airwater, mean photon and secondary electron energies. To study the impact of removing the flattening filter on the beam quality correction factors k Q , this factor for detailed ionization chamber models was calculated by Monte Carlo simulations. Stopping power ratios (L¯/ρ)airwater and k Q values for different ionization chambers as a function of TPR1020 and %dd(10) x were calculated. Moreover, mean photon energies in air and at the point of measurement in water as well as mean secondary electron energies at the point of measurement were calculated. The results revealed that removing the flattening filter led to a change within 0.3% in the relationship between %dd(10) x and (L¯/ρ)airwater, whereby the relationship between TPR1020 and (L¯/ρ)airwater changed up to 0.8% for high energy photon beams. However, TPR1020 was a good predictor of (L¯/ρ)airwater for both types of linear accelerator with energies < 10 MeV with a maximal deviation between both types of accelerators of 0.23%. According to the results, the mean photon energy below the linear accelerators head as well as at the point of measurement may not be suitable as a predictor of (L¯/ρ)airwater and k Q to merge the dosimetry of both linear accelerator types. It was possible to derive (L¯/ρ)airwater using the mean secondary electron energy at the point of measurement as a predictor with an accuracy of 0.17%. A bias between k Q for linear accelerators with and without flattening filter within 1.1% and 1.6% was observed for TPR1020 and %dd(10) x respectively. The results of this study have shown that removing the flattening filter led to a change in the relationship between the well-known beam quality specifiers and dosimetric quantities at the point of measurement, namely (L¯/ρ)airwater, mean photon and electron energy. Furthermore, the results show that a beam profile correction is important for dose measurements with large ionization chambers in flattening filter free beams. © 2017 American Association of Physicists in Medicine.

  11. Q-controlled amplitude modulation atomic force microscopy in liquids: An analysis

    NASA Astrophysics Data System (ADS)

    Hölscher, H.; Schwarz, U. D.

    2006-08-01

    An analysis of amplitude modulation atomic force microscopy in liquids is presented with respect to the application of the Q-Control technique. The equation of motion is solved by numerical and analytic methods with and without Q-Control in the presence of a simple model interaction force adequate for many liquid environments. In addition, the authors give an explicit analytical formula for the tip-sample indentation showing that higher Q factors reduce the tip-sample force. It is found that Q-Control suppresses unwanted deformations of the sample surface, leading to the enhanced image quality reported in several experimental studies.

  12. Distinct temperature sensitivity of soil carbon decomposition in forest organic layer and mineral soil

    PubMed Central

    Xu, Wenhua; Li, Wei; Jiang, Ping; Wang, Hui; Bai, Edith

    2014-01-01

    The roles of substrate availability and quality in determining temperature sensitivity (Q10) of soil carbon (C) decomposition are still unclear, which limits our ability to predict how soil C storage and cycling would respond to climate change. Here we determined Q10 in surface organic layer and subsurface mineral soil along an elevation gradient in a temperate forest ecosystem. Q10 was calculated by comparing the times required to respire a given amount of soil C at 15 and 25°C in a 350-day incubation. Results indicated that Q10 of the organic layer was 0.22–0.71 (absolute difference) higher than Q10 of the mineral soil. Q10 in both the organic layer (2.5–3.4) and the mineral soil (2.1–2.8) increased with decreasing substrate quality during the incubation. This enhancement of Q10 over incubation time in both layers suggested that Q10 of more labile C was lower than that of more recalcitrant C, consistent with the Arrhenius kinetics. No clear trend of Q10 was found along the elevation gradient. Because the soil organic C pool of the organic layer in temperate forests is large, its higher temperature sensitivity highlights its importance in C cycling under global warming. PMID:25270905

  13. High quality factor GaAs-based photonic crystal microcavities by epitaxial re-growth.

    PubMed

    Prieto, Ivan; Herranz, Jesús; Wewior, Lukasz; González, Yolanda; Alén, Benito; González, Luisa; Postigo, Pablo A

    2013-12-16

    We investigate L7 photonic crystal microcavities (PCMs) fabricated by epitaxial re-growth of GaAs pre-patterned substrates, containing InAs quantum dots. The resulting PCMs show hexagonal shaped nano-holes due to the development of preferential crystallographic facets during the re-growth step. Through a careful control of the fabrication processes, we demonstrate that the photonic modes are preserved throughout the process. The quality factor (Q) of the photonic modes in the re-grown PCMs strongly depends on the relative orientation between photonic lattice and crystallographic directions. The optical modes of the re-grown PCMs preserve the linear polarization and, for the most favorable orientation, a 36% of the Q measured in PCMs fabricated by the conventional procedure is observed, exhibiting values up to ~6000. The results aim to the future integration of site-controlled QDs with high-Q PCMs for quantum photonics and quantum integrated circuits.

  14. Validity of a questionnaire measuring the world health organization concept of health system responsiveness with respect to perinatal services in the Dutch obstetric care system.

    PubMed

    van der Kooy, Jacoba; Valentine, Nicole B; Birnie, Erwin; Vujkovic, Marijana; de Graaf, Johanna P; Denktaş, Semiha; Steegers, Eric A P; Bonsel, Gouke J

    2014-12-03

    The concept of responsiveness, introduced by the World Health Organization (WHO), addresses non-clinical aspects of health service quality that are relevant regardless of provider, country, health system or health condition. Responsiveness refers to "aspects related to the way individuals are treated and the environment in which they are treated" during health system interactions. This paper assesses the psychometric properties of a newly developed responsiveness questionnaire dedicated to evaluating maternal experiences of perinatal care services, called the Responsiveness in Perinatal and Obstetric Health Care Questionnaire (ReproQ), using the eight-domain WHO concept. The ReproQ was developed between October 2009 and February 2010 by adapting the WHO Responsiveness Questionnaire items to the perinatal care context. The psychometric properties of feasibility, construct validity, and discriminative validity were empirically assessed in a sample of Dutch women two weeks post partum. A total of 171 women consented to participation. Feasibility: the interviews lasted between 20 and 40 minutes and the overall missing rate was 8%. Construct validity: mean Cronbach's alphas for the antenatal, birth and postpartum phase were: 0.73 (range 0.57-0.82), 0.84 (range 0.66-0.92), and 0.87 (range 0.62-0.95) respectively. The item-own scale correlations within all phases were considerably higher than most of the item-other scale correlations. Within the antenatal care, birth care and post partum phases, the eight factors explained 69%, 69%, and 76% of variance respectively. Discriminative validity: overall responsiveness mean sum scores were higher for women whose children were not admitted. This confirmed the hypothesis that dissatisfaction with health outcomes is transferred to their judgement on responsiveness of the perinatal services. The ReproQ interview-based questionnaire demonstrated satisfactory psychometric properties to describe the quality of perinatal care in the Netherlands, with the potential to discriminate between different levels of quality of care. In view of the relatively small sample, further testing and research is recommended.

  15. High temperature (NaBi)0.48□0.04Bi2Nb2O9-based piezoelectric ceramics

    NASA Astrophysics Data System (ADS)

    Gai, Zhi-Gang; Wang, Jin-Feng; Zhao, Ming-Lei; Wang, Chun-Ming; Zang, Guo-Zhong; Ming, Bao-Quan; Qi, Peng; Zhang, Shujun; Shrout, Thomas R.

    2006-07-01

    The effect of (LiCe) substitution for A site on the properties of (NaBi)0.48◻0.04Bi2Nb2O9 (NB◻N)-based ceramics was investigated. The coercive fields (EC) of NB◻N)-based ceramics were significantly decreased from 61.0to32.5kV/cm and the Curie temperature (TC) gradually decreases from 820to803°C with increasing the (LiCe) modification. The piezoelectric coefficient d33, planar coupling factor kp, and mechanical quality factor Q of (NaBi)0.38(LiCe)0.05◻0.14Bi2Nb2O9 ceramic were found to be 27pC/N, 11.2%, and 2600, respectively, together with the high TC (˜809°C) and stable piezoelectric properties, demonstrating that the (LiCe) modified NB◻N-based material a promising candidate for high temperature applications.

  16. Universal behavior of the γ⁎γ→(π0,η,η′) transition form factors

    PubMed Central

    Melikhov, Dmitri; Stech, Berthold

    2012-01-01

    The photon transition form factors of π, η and η′ are discussed in view of recent measurements. It is shown that the exact axial anomaly sum rule allows a precise comparison of all three form factors at high-Q2 independent of the different structures and distribution amplitudes of the participating pseudoscalar mesons. We conclude: (i) The πγ form factor reported by Belle is in excellent agreement with the nonstrange I=0 component of the η and η′ form factors obtained from the BaBar measurements. (ii) Within errors, the πγ form factor from Belle is compatible with the asymptotic pQCD behavior, similar to the η and η′ form factors from BaBar. Still, the best fits to the data sets of πγ, ηγ, and η′γ form factors favor a universal small logarithmic rise Q2FPγ(Q2)∼log(Q2). PMID:23226917

  17. Effects of Aperture Size on Q factor and Shielding Effectiveness of a Cubic Resonator

    NASA Astrophysics Data System (ADS)

    Parr, Stefan; Chromy, Stephan; Dickmann, Stefan; Schaarschmidt, Martin

    2017-09-01

    The EMC properties of a cubic metallic shield are highly affected by its resonances. At the resonant frequencies, the shielding effectiveness (SE) collapses, which results in high field strengths inside the cavity. This can cause failure or even breakdown of electronic devices inside the shield. The resonant behaviour is mainly determined by the quality or Q factor of the shield. In this paper, the effects of the aperture size on the Q factor and the SE of an electrically large, cubic shield are analysed. At first, a method is developed in order to determine the Q factor based on the resonance behaviour of the shield in time domain. Only the first resonance of the shield is considered therefore. The results are evaluated for different aperture diameters and compared with theory for the Q factor. The dominant coupling mechanism of electromagnetic energy into the shield is thus identified. Then the effect of aperture size on the SE is analysed. The excitation of resonances is very probable if the interfering signal is an ultrawideband (UWB) pulse, which constitutes a typical intentional electromagnetic interference (IEMI) scenario. Therefore, the relation between aperture size and SE is analysed using the theory of the transient SE for a broadband signal with a constant spectral density distribution. The results show, that a worst case aperture size exists, where the SE has its minimum.

  18. Photopumped infrared vertical-cavity surface-emitting laser

    NASA Astrophysics Data System (ADS)

    Hadji, E.; Bleuse, J.; Magnea, N.; Pautrat, J. L.

    1996-04-01

    The feasibility of a photopumped infrared vertical-cavity surface-emitting laser (VCSEL) based on CdHgTe alloys is demonstrated. The structure of the VCSEL consists of a 16.5-period Cd0.4Hg0.6Te/Cd0.75Hg0.25Te bottom Bragg reflector and a 3λ/4 thick Cd0.75Hg0.25Te cavity, containing a 100-nm-thick well, grown by molecular beam epitaxy. The top mirror is a 7-period YF3/ZnS dielectric stack. The cavity quality factor is Q=350. This heterostructure VCSEL operates at 3.06 μm with a measured power density threshold of 45 kW/cm2 at 10 K.

  19. Enteric coating of soft gelatin capsules by spouted bed: effect of operating conditions on coating efficiency and on product quality.

    PubMed

    Pissinati, Rafael; Oliveira, Wanderley Pereira

    2003-05-01

    The present study was conducted in order to analyze the viability of the spouted bed process for application of a gastric-resistant coating to soft gelatin capsules. The variables investigated were: included angle of conical base, (gamma), the relation between the feed mass flow rate of the coating suspension and the feed mass flow rate of spouting gas (W(s)/W(g)); the ratio between the flow rate of the spouting gas and the flow rate at minimum spouting condition (Q/Q(ms)); the mass of capsules in the bed (M(0)), and the capsule's size. The product quality was measured by disintegration tests, traction x deformation tests, image analysis and by the evaluation of the coating mass distribution and shape factor variation during the coating operation. The experiments were performed in a spouted bed with a column diameter of 200 mm and included a conical base angle of 40 degrees. The best coating efficiency values were obtained for M(0)=300 g. Coating efficiency tended to increase with increasing W(s)/W(g) ratio. Disintegration tests showed that the gastric-resistant effect was obtained with a coating mass of 3.86 mg/cm(2). The shape factor increase during the coating operation. The capsule's coating mass distribution tended to maintain the original distribution.

  20. Investigations on LGS and LGT crystals to realize BAW resonators.

    PubMed

    Imbaud, Joël; Boy, Jean-Jacques; Galliou, Serge; Bourquin, Roger; Romand, Jean Pierre

    2008-11-01

    The LGS family are promising materials for the design of high quality bulk acoustic wave resonators. We have manufactured many plano-convex 10 MHz 5th overtone Y-cut resonators using langasite (LGS, La(3)Ga(5)SiO(14)) and langatate (LGT, La(3)Ga(5.5)Ta(0.5)O(14)) crystals. We observed that the quality factor strongly depends on the polishing method, the supplier of the material, and on the energy trapping. For quartz crystals, we have found that resulting IR spectra exhibit absorption peaks more or less deep, linked to defects. These predominant criteria are not surprising, but they have to be defined in manner similar to that used for quartz crystal. A satisfying machining and polishing method has been first applied to elaborate high Q resonators, and a comparison between samples of LGS and LGT materials from different suppliers is established. In addition, LGT resonators are characterized by their motional parameters and frequency-temperature curves. Nevertheless, one of the main results is that the measured Q x f product is not the expected one. We present results of Q-factor versus radius of curvature: it appears that an optimization should be performed and that this last one cannot be directly transposed from that of quartz crystal resonator. Currently, the best resonator that we have made has a Q x f product of 1.4 x 10(13) on its 5th overtone (1.7 x 10(13) on its 9th overtone). This result is slightly higher than the similar parameter obtained on a state-of-the-art SC-cut quartz crystal resonator working at the same frequency.

  1. Social inequalities and cancer: can the European deprivation index predict patients' difficulties in health care access? a pilot study

    PubMed Central

    Moriceau, Guillaume; Bourmaud, Aurélie; Tinquaut, Fabien; Oriol, Mathieu; Jacquin, Jean-Philippe; Fournel, Pierre; Magné, Nicolas; Chauvin, Franck

    2016-01-01

    Context The European Deprivation Index (EDI), is a new ecological estimate for Socio-Economic Status (SES). This study postulates that Time-To-Treatment could be used as a cancer quality-of -care surrogate in order to identify the association between cancer patient's SES and quality of care in a French comprehensive cancer center. Methods retrospective mono-centered cohort study. All consecutive incoming adult patients diagnosed for breast cancer(BC), prostate cancer(PC), colorectal cancer (CRC), lung cancer(LC) or sarcoma(S) were included between January 2013 and December 2013. The association of EDI and Time-To-Diagnosis(TTD), as well as Time-To-Treatment(TTT) was analyzed using a cox regression, and a strata analysis per tumor site was performed. Results 969 patients were included. Primitive tumor site was 505 BC(52%), 169 PC(17%), 145 LC(15%), 116 CRC(12%), and 34 S(4%). Median TTD was 1.41 months (Q1-Q3 0.5 to 3.5 months). Median TTT was 0.9 months (0.4 - 1.4). In a multivariate analysis, we identified the tumor site as a predictive factor to influence TTD, shorter for BC (0.75months, [0.30- 1.9]) than PC (4.69 months [1.6-29.7]), HR 0.27 95%CI= [0.22-0.34], p < 0.001. TTT was also shorter for BC (0.75months [0.4-1.1]) than PC (2.02 [0.9-3.2]), HR 0.32 95%CI= [0.27-0.39], p < 0.001. EDI quintiles were not found associated with either TTT or TTD. Conclusions Deprivation estimated by the EDI does not appear to be related to an extension of the Time-to-Diagnosis or Time-to-Treatment in our real-life population. Further research should be done to identify other frailty-sensitive factors that could be responsible for delays in care. PMID:26540571

  2. Measuring Client Experiences in Maternity Care under Change: Development of a Questionnaire Based on the WHO Responsiveness Model

    PubMed Central

    Scheerhagen, Marisja; van Stel, Henk F.; Birnie, Erwin; Franx, Arie; Bonsel, Gouke J.

    2015-01-01

    Background Maternity care is an integrated care process, which consists of different services, involves different professionals and covers different time windows. To measure performance of maternity care based on clients' experiences, we developed and validated a questionnaire. Methods and Findings We used the 8-domain WHO Responsiveness model, and previous materials to develop a self-report questionnaire. A dual study design was used for development and validation. Content validity of the ReproQ-version-0 was determined through structured interviews with 11 pregnant women (≥28 weeks), 10 women who recently had given birth (≤12 weeks), and 19 maternity care professionals. Structured interviews established the domain relevance to the women; all items were separately commented on. All Responsiveness domains were judged relevant, with Dignity and Communication ranking highest. Main missing topic was the assigned expertise of the health professional. After first adaptation, construct validity of the ReproQ-version-1 was determined through a web-based survey. Respondents were approached by maternity care organizations with different levels of integration of services of midwives and obstetricians. We sent questionnaires to 605 third trimester pregnant women (response 65%), and 810 women 6 weeks after delivery (response 55%). Construct validity was based on: response patterns; exploratory factor analysis; association of the overall score with a Visual Analogue Scale (VAS), known group comparisons. Median overall ReproQ score was 3.70 (range 1–4) showing good responsiveness. The exploratory factor analysis supported the assumed domain structure and suggested several adaptations. Correlation of the VAS rating and overall ReproQ score (antepartum, postpartum) supported validity (r = 0.56; 0.59, p<0.001 Spearman's correlation coefficient). Pre-stated group comparisons confirmed the expected difference following a good vs. adverse birth outcome. Fully integrated organizations performed slightly better (median = 3.78) than less integrated organizations (median = 3.63; p<0.001). Participation rate of women with a low educational level and/or a non-western origin was low. Conclusions The ReproQ appears suitable for assessing quality of maternity care from the clients' perspective. Recruitment of disadvantaged groups requires additional non-digital approaches. PMID:25671310

  3. Quadrupole-Quadrupole Interactions to Control Plasmon-Induced Transparency

    NASA Astrophysics Data System (ADS)

    Rana, Goutam; Deshmukh, Prathmesh; Palkhivala, Shalom; Gupta, Abhishek; Duttagupta, S. P.; Prabhu, S. S.; Achanta, VenuGopal; Agarwal, G. S.

    2018-06-01

    Radiative dipolar resonance with Lorentzian line-shape induces the otherwise dark quadrupolar resonances resulting in electromagnetically induced transparency (EIT). The two interfering excitation pathways of the dipole are earlier shown to result in a Fano line shape with a high figure of merit suitable for sensing. In metamaterials made of metal nanorods or antennas, the plasmonic EIT (PIT) efficiency depends on the overlap of the dark and bright mode spectra as well as the asymmetry resulting from the separation between the monomer (dipole) and dimer (quadrupole) that governs the coupling strength. Increasing asymmetry in these structures leads to the reduction of the figure of merit due to a broadening of the Fano resonance. We demonstrate a PIT system in which the simultaneous excitation of two dipoles result in double PIT. The corresponding two quadrupoles interact and control the quality factor (Q ) of the PIT resonance. We show an antiresonancelike symmetric line shape with nonzero asymmetry factors. The PIT resonance vanishes due to quadrupole-quadrupole coupling. A Q factor of more than 100 at 0.977 THz is observed, which is limited by the experimental resolution of 6 GHz. From polarization-dependent studies we show that the broadening of the Lorentzian resonance is due to scattering-induced excitation of orthogonally oriented dipoles in the monomer and dimer bars in the terahertz regime. The high Q factors in the terahertz frequency region demonstrated here are interesting for sensing application.

  4. High-Q and highly reproducible microdisks and microlasers.

    PubMed

    Zhang, Nan; Wang, Yujie; Sun, Wenzhao; Liu, Shuai; Huang, Can; Jiang, Xiaoshun; Xiao, Min; Xiao, Shumin; Song, Qinghai

    2018-01-25

    High quality (Q) factor microdisks are fundamental building blocks of on-chip integrated photonic circuits and biological sensors. The resonant modes in microdisks circulate near their boundaries, making their performances strongly dependent upon surface roughness. Surface-tension-induced microspheres and microtoroids are superior to other dielectric microdisks when comparing Q factors. However, most photonic materials such as silicon and negative photoresists are hard to be reflowed and thus the realizations of high-Q microdisks are strongly dependent on electron-beam lithography. Herein, we demonstrate a robust, cost-effective, and highly reproducible technique to fabricate ultrahigh-Q microdisks. By using silica microtoroids as masks, we have successfully replicated their ultrasmooth boundaries in a photoresist via anisotropic dry etching. The experimentally recorded Q factors of passive microdisks can be as large as 1.5 × 10 6 . Similarly, ultrahigh Q microdisk lasers have also been replicated in dye-doped polymeric films. The laser linewidth is only 8 pm, which is limited by the spectrometer and is much narrower than that in previous reports. Meanwhile, high-Q deformed microdisks have also been fabricated by controlling the shape of microtoroids, making the internal ray dynamics and external directional laser emissions controllable. Interestingly, this technique also applies to other materials. Silicon microdisks with Q > 10 6 have been experimentally demonstrated with a similar process. We believe this research will be important for the advances of high-Q micro-resonators and their applications.

  5. Q-TWiST analysis comparing ipilimumab/dacarbazine vs placebo/dacarbazine for patients with stage III/IV melanoma.

    PubMed

    Sherrill, B; Wang, J; Kotapati, S; Chin, K

    2013-07-09

    Study CA184024 was a multinational, randomised, double-blind, phase 3 study comparing ipilimumab/dacarbazine (DTIC) vs placebo/DTIC in patients with untreated stage III/IV melanoma, which showed that ipilimumab significantly improves survival in patients with metastatic melanoma. The objective of this analysis was to compare the quality-adjusted survival experience among patients in this trial. Survival time was partitioned into health states: toxicity, time before progression without toxicity, and relapse until death or end of follow-up. Q-TWiST (quality-adjusted time without symptoms of disease or toxicity of treatment) was calculated as the utility-weighted sum of the mean health state durations. Analyses were repeated over extended follow-up periods. Based on a combination of trial-based and external utility scores, the Q-TWiST difference in this trial was 0.50 months (P=0.0326) favoring ipilimumab after 1 year. The Q-TWiST difference was 1.5 months with 2 years of follow-up (P=0.0091), 2.36 months at 3 years (P=0.005) and 3.28 months at 4 years (P=0.0074). During the first year of study, there was little difference between groups in quality-adjusted survival. However, after 2, 3 and 4 years follow-up for patients with extended survival, the benefits of IPI+DTIC vs PLA+DTIC for advanced melanoma continue to accrue.

  6. Soliton all-optical logic AND gate with semiconductor optical amplifier-assisted Mach-Zehnder interferometer

    NASA Astrophysics Data System (ADS)

    Kotb, Amer; Zoiros, Kyriakos E.

    2016-08-01

    The concept of soliton provides a line in research in telecommunications systems. In the present study, a soliton all-optical logic AND gate with semiconductor optical amplifier (SOA)-assisted Mach-Zehnder interferometer has been numerically simulated and investigated. The dependence of the output quality factor (Q-factor) on the soliton characteristics and SOA parameters has been examined and assessed. The obtained results demonstrate that the soliton AND gate is capable of operating at a data rate of 80 Gb/s with logical correctness and high-output Q-factor.

  7. Piezoelectric micromachined ultrasonic transducers with low thermoelastic dissipation and high quality factor

    NASA Astrophysics Data System (ADS)

    Chen, Xuying; Liu, Xinxin; Wang, Tao; Le, Xianhao; Ma, Fangyi; Lee, Chengkuo; Xie, Jin

    2018-05-01

    Thermoelastic dissipation is one of the main dissipative mechanisms in piezoelectric micromachined ultrasonic transducers (pMUTs). In this paper, we firstly propose pMUTs with etching holes to decrease thermoelastic dissipation and enhance quality factor (Q). The etching holes effectively disturb heat flow, and thus reduce thermoelastic loss. Working mechanism based on the Zener’s model is interpreted. The experiment results show that the Q of pMUT with three rows of holes is increased by 139% from 2050 to 4909 compared with the traditional one. Temperature coefficient of frequency (TCF) and vibration performance are also improved. The enhanced pMUT can be widely used in measurement of Doppler shift and relative high power applications.

  8. Glass-embedded two-dimensional silicon photonic crystal devices with a broad bandwidth waveguide and a high quality nanocavity.

    PubMed

    Jeon, Seung-Woo; Han, Jin-Kyu; Song, Bong-Shik; Noda, Susumu

    2010-08-30

    To enhance the mechanical stability of a two-dimensional photonic crystal slab structure and maintain its excellent performance, we designed a glass-embedded silicon photonic crystal device consisting of a broad bandwidth waveguide and a nanocavity with a high quality (Q) factor, and then fabricated the structure using spin-on glass (SOG). Furthermore, we showed that the refractive index of the SOG could be tuned from 1.37 to 1.57 by varying the curing temperature of the SOG. Finally, we demonstrated a glass-embedded heterostructured cavity with an ultrahigh Q factor of 160,000 by adjusting the refractive index of the SOG.

  9. Nucleon form factors from quenched lattice QCD with domain wall fermions

    NASA Astrophysics Data System (ADS)

    Sasaki, Shoichi; Yamazaki, Takeshi

    2008-07-01

    We present a quenched lattice calculation of the weak nucleon form factors: vector [FV(q2)], induced tensor [FT(q2)], axial vector [FA(q2)] and induced pseudoscalar [FP(q2)] form factors. Our simulations are performed on three different lattice sizes L3×T=243×32, 163×32, and 123×32 with a lattice cutoff of a-1≈1.3GeV and light quark masses down to about 1/4 the strange quark mass (mπ≈390MeV) using a combination of the DBW2 gauge action and domain wall fermions. The physical volume of our largest lattice is about (3.6fm)3, where the finite volume effects on form factors become negligible and the lower momentum transfers (q2≈0.1GeV2) are accessible. The q2 dependences of form factors in the low q2 region are examined. It is found that the vector, induced tensor, and axial-vector form factors are well described by the dipole form, while the induced pseudoscalar form factor is consistent with pion-pole dominance. We obtain the ratio of axial to vector coupling gA/gV=FA(0)/FV(0)=1.219(38) and the pseudoscalar coupling gP=mμFP(0.88mμ2)=8.15(54), where the errors are statistical errors only. These values agree with experimental values from neutron β decay and muon capture on the proton. However, the root mean-squared radii of the vector, induced tensor, and axial vector underestimate the known experimental values by about 20%. We also calculate the pseudoscalar nucleon matrix element in order to verify the axial Ward-Takahashi identity in terms of the nucleon matrix elements, which may be called as the generalized Goldberger-Treiman relation.

  10. High-Q silicon-on-insulator slot photonic crystal cavity infiltrated by a liquid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Caër, Charles; Le Roux, Xavier; Cassan, Eric, E-mail: eric.cassan@u-psud.fr

    We report the experimental realization of a high-Q slot photonic crystal cavity in Silicon-On-Insulator (SOI) configuration infiltrated by a liquid. Loaded Q-factor of 23 000 is measured at telecom wavelength. The intrinsic quality factor inferred from the transmission spectrum is higher than 200 000, which represents a record value for slot photonic crystal cavities on SOI, whereas the maximum of intensity of the cavity is roughly equal to 20% of the light transmitted in the waveguide. This result makes filled slot photonic crystal cavities very promising for silicon-based light emission and ultrafast nonlinear optics.

  11. Optoreflectometry determination of the resonance properties of a vocal fold.

    PubMed

    Garrel, Renaud; Nicollas, Richard; Giovanni, Antoine; Ouaknine, Maurice

    2007-09-01

    A new method of measuring the resonance properties of a vocal fold using electromagnetic excitation and laser optoreflectometry for response monitoring is described. Two resonance peaks were experimentally identified with one magnet stuck on the vocal fold at frequencies F0(1m)=54.7 Hz and F0'(1m)=35.8 Hz. The addition of a second magnet allowed calculation of the actual viscoelastic properties of the vocal fold: F0=71.8 Hz; quality factor Q=8.03; mass m=0.057 g; stiffness k=11.6 Nm; and damping zeta=0.0032 Nm(-1). A numerical simulation of a two-layered model verified the experimental data.

  12. Ultra-compact air-mode photonic crystal nanobeam cavity integrated with bandstop filter for refractive index sensing.

    PubMed

    Sun, Fujun; Fu, Zhongyuan; Wang, Chunhong; Ding, Zhaoxiang; Wang, Chao; Tian, Huiping

    2017-05-20

    We propose and investigate an ultra-compact air-mode photonic crystal nanobeam cavity (PCNC) with an ultra-high quality factor-to-mode volume ratio (Q/V) by quadratically tapering the lattice space of the rectangular holes from the center to both ends while other parameters remain unchanged. By using the three-dimensional finite-difference time-domain method, an optimized geometry yields a Q of 7.2×10 6 and a V∼1.095(λ/n Si ) 3 in simulations, resulting in an ultra-high Q/V ratio of about 6.5×10 6 (λ/n Si ) -3 . When the number of holes on either side is 8, the cavity possesses a high sensitivity of 252 nm/RIU (refractive index unit), a high calculated Q-factor of 1.27×10 5 , and an ultra-small effective V of ∼0.758(λ/n Si ) 3 at the fundamental resonant wavelength of 1521.74 nm. Particularly, the footprint is only about 8×0.7  μm 2 . However, inevitably our proposed PCNC has several higher-order resonant modes in the transmission spectrum, which makes the PCNC difficult to be used for multiplexed sensing. Thus, a well-designed bandstop filter with weak sidelobes and broad bandwidth based on a photonic crystal nanobeam waveguide is created to connect with the PCNC to filter out the high-order modes. Therefore, the integrated structure presented in this work is promising for building ultra-compact lab-on-chip sensor arrays with high density and parallel-multiplexing capability.

  13. Association of neighborhood-level factors with hospitalization for community-associated methicillin-resistant Staphylococcus aureus, New York City, 2006: a multilevel observational study.

    PubMed

    Farr, Amanda M; Marx, Melissa A; Weiss, Don; Nash, Denis

    2013-02-13

    Hospitalizations with community-associated methicillin-resistant Staphylococcus aureus (CA-MRSA) infection have increased in New York City, with substantial geographic variation across neighborhoods. While individual-level risk factors, such as age, sex, HIV infection, and diabetes have been described, the role of neighborhood-level factors (e.g., neighborhood HIV prevalence or income) has not been examined. To explore plausible neighborhood-level factors associated with CA-MRSA-related hospitalizations, a retrospective analysis was conducted using New York City hospital discharges from 2006 and New York City-specific survey and health department surveillance data. CA-MRSA-related hospitalizations were identified using diagnosis codes and admission information. Associations were determined by using sex-specific multilevel logistic regression. The CA-MRSA hospitalization rate varied by more than six-fold across New York City neighborhoods. Females hospitalized with CA-MRSA had more than twice the odds of residing in neighborhoods in the highest quintile of HIV prevalence (adjusted odds ratio [AOR](Q5 vs. Q1) 2.3, 95% CI: 1.2, 2.7). Both males and females hospitalized with CA-MRSA had nearly twice the odds of residing in neighborhoods with moderately high proportion of men who have sex with men (MSM) residing in the neighborhood (males: AOR(Q4 vs. Q1) 1.7, 95% CI: 1.1, 2.7; females: AOR(Q4 vs. Q1) 2.0, 95% CI: 1.1, 3.6); but this association did not hold for neighborhoods in the highest quintile (males: AOR(Q5 vs. Q1) 1.2, 95% CI: 0.76, 1.8; females: AOR(Q5 vs. Q1) 1.5, 95% CI: 0.82, 2.7). Neighborhood-level characteristics were associated with CA-MRSA hospitalization odds, independent of individual-level risk factors, and may contribute to the population-level burden of CA-MRSA infection.

  14. The effect of safety factor profile on transport in steady-state, high-performance scenarios

    DOE PAGES

    Holcomb, C. T.; Ferron, J. R.; Luce, T. C.; ...

    2012-03-09

    In this study, an analysis of the dependence of transport on the safety factor profile in high-performance, steady-state scenario discharges is presented. This is based on experimental scans of q 95 and q min taken with fixed β N, toroidal field, double-null plasma shape, divertor pumping, and electron cyclotron current drive input. The temperature and thermal diffusivity profiles were found to vary considerably with the q-profile, and these variations were significantly different for electrons and ions. With fixed q 95, both temperature profiles increase and broaden as q min is increased and the magnetic shear becomes low or negative inmore » the inner half radius, but these temperature profile changes are stronger for the electrons. Power balance calculations show the peak in the ion thermal diffusivity (χ i) at ρ – 0.6 – 0.8 increases with q 95 or q min.« less

  15. Impact of nitrogen doping of niobium superconducting cavities on the sensitivity of surface resistance to trapped magnetic flux

    NASA Astrophysics Data System (ADS)

    Gonnella, Dan; Kaufman, John; Liepe, Matthias

    2016-02-01

    Future particle accelerators such as the SLAC "Linac Coherent Light Source-II" (LCLS-II) and the proposed Cornell Energy Recovery Linac require hundreds of superconducting radio-frequency (SRF) niobium cavities operating in continuous wave mode. In order to achieve economic feasibility of projects such as these, the cavities must achieve a very high intrinsic quality factor (Q0) to keep cryogenic losses within feasible limits. To reach these high Q0's in the case of LCLS-II, nitrogen-doping of niobium cavities has been selected as the cavity preparation technique. When dealing with Q0's greater than 1 × 1010, the effects of ambient magnetic field on Q0 become significant. Here, we show that the sensitivity to RF losses from trapped magnetic field in a cavity's walls is strongly dependent on the cavity preparation. Specifically, standard electropolished and 120 °C baked cavities show a sensitivity of residual resistance from trapped magnetic flux of ˜0.6 and ˜0.8 nΩ/mG trapped, respectively, while nitrogen-doped cavities show a higher sensitivity of residual resistance from trapped magnetic flux of ˜1 to 5 nΩ/mG trapped. We show that this difference in sensitivities is directly related to the mean free path of the RF surface layer of the niobium: shorter mean free paths lead to less sensitivity of residual resistance to trapped magnetic flux in the dirty limit (ℓ ≪ ξ0), while longer mean free paths lead to lower sensitivity of residual resistance to trapped magnetic flux in the clean limit (ℓ ≫ ξ0). These experimental results are also shown to have good agreement with recent theoretical predictions for pinned vortex lines oscillating in RF fields.

  16. Compact rf polarizer and its application to pulse compression systems

    DOE PAGES

    Franzi, Matthew; Wang, Juwen; Dolgashev, Valery; ...

    2016-06-01

    We present a novel method of reducing the footprint and increasing the efficiency of the modern multi-MW rf pulse compressor. This system utilizes a high power rf polarizer to couple two circular waveguide modes in quadrature to a single resonant cavity in order to replicate the response of a traditional two cavity configuration using a 4-port hybrid. The 11.424 GHz, high-Q, spherical cavity has a 5.875 cm radius and is fed by the circularly polarized signal to simultaneously excite the degenerate TE 114 modes. The overcoupled spherical cavity has a Q 0 of 9.4×10 4 and coupling factor (β) ofmore » 7.69 thus providing a loaded quality factor Q L of 1.06×10 4 with a fill time of 150 ns. Cold tests of the polarizer demonstrated good agreement with the numerical design, showing transmission of -0.05 dB and reflection back to the input rectangular WR 90 waveguide less than -40 dB over a 100 MHz bandwidth. This novel rf pulse compressor was tested at SLAC using XL-4 Klystron that provided rf power up to 32 MW and generated peak output power of 205 MW and an average of 135 MW over the discharged signal. A general network analysis of the polarizer is discussed as well as the design and high power test of the rf pulse compressor.« less

  17. 3D-quantitative structure-activity relationship studies on benzothiadiazepine hydroxamates as inhibitors of tumor necrosis factor-alpha converting enzyme.

    PubMed

    Murumkar, Prashant R; Giridhar, Rajani; Yadav, Mange Ram

    2008-04-01

    A set of 29 benzothiadiazepine hydroxamates having selective tumor necrosis factor-alpha converting enzyme inhibitory activity were used to compare the quality and predictive power of 3D-quantitative structure-activity relationship, comparative molecular field analysis, and comparative molecular similarity indices models for the atom-based, centroid/atom-based, data-based, and docked conformer-based alignment. Removal of two outliers from the initial training set of molecules improved the predictivity of models. Among the 3D-quantitative structure-activity relationship models developed using the above four alignments, the database alignment provided the optimal predictive comparative molecular field analysis model for the training set with cross-validated r(2) (q(2)) = 0.510, non-cross-validated r(2) = 0.972, standard error of estimates (s) = 0.098, and F = 215.44 and the optimal comparative molecular similarity indices model with cross-validated r(2) (q(2)) = 0.556, non-cross-validated r(2) = 0.946, standard error of estimates (s) = 0.163, and F = 99.785. These models also showed the best test set prediction for six compounds with predictive r(2) values of 0.460 and 0.535, respectively. The contour maps obtained from 3D-quantitative structure-activity relationship studies were appraised for activity trends for the molecules analyzed. The comparative molecular similarity indices models exhibited good external predictivity as compared with that of comparative molecular field analysis models. The data generated from the present study helped us to further design and report some novel and potent tumor necrosis factor-alpha converting enzyme inhibitors.

  18. Teacher Quality 2.0: Toward a New Era in Education Reform

    ERIC Educational Resources Information Center

    Hess, Frederick M., Ed.; McShane, Michael Q., Ed.

    2014-01-01

    In "Teacher Quality 2.0," American Enterprise Institute (AEI) education experts Frederick M. Hess and Michael Q. McShane convene a diverse array of contributors to examine fruitful innovations that promise to improve teacher quality in a more strategic way. Much of the cutting-edge work in teacher quality is happening in nontraditional…

  19. Should we use the shorter Thai-version quality of life and symptoms questionnaires in women with overactive bladder?

    PubMed

    Bunyavejchevin, Suvit; Liao, Limin; Lu, Shing-Hwa; Choo, Myung-Soo; Rabbani, Khalid Javed; Havanond, Piyalamporn

    2015-08-01

    The aim of this study was to test: (i) the validation and reliability of the Thai versions of overactive bladder (OAB) questionnaires (the 8-item and 3-item Overactive Bladder Symptoms Score questionnaires [OAB-v8 and OAB-v3, respectively] and the Overactive Bladder Questionnaire [OAB-q]); and (ii) the correlation of the OAB-v8, OAB-v3, and the single-question Quality of Life Questionnaire (1-QoL) to the OAB-q in Thai women with OAB. During January to March 2011, 36 Thai women with OAB attending a urogynecology clinic at Chulalongkorn Hospital, Bangkok, Thailand were recruited. All questionnaires were given as a psychometric test twice, 2 weeks apart. Cronbach's alpha of the OAB-v8 was higher (and above 0.7) than OAB-v3 at both week 0 and week 2. The intraclass correlations (ricc ) were 0.64, 0.85, and 0.97 for the OABV8, OAB-v3, and OAB-q, respectively. The correlation coefficient (r) of OAB-v3 and OAB-q at weeks 0 and 2 (0.40 and 0.49) were lower than those for OAB-v8 and OAB-q at weeks 0 and 2 (0.62 and 0.62). All questions on the OAB-v3 had a lower weighted kappa than OAB-v8. There was no statistically significant difference in the OAB-q score in each level of 1-QoL score at week 0 (P = 0.12) and at week 2 (P = 0.29). The reliability of the OAB-v3 is poorer than that of the OAB-v8. The OAB-v3 is poorer correlated to the OAB-q than to the OAB-v8. A short questionnaire, such as the OAB-v3 and the 1-QoL, has poor reliability and is poorly correlated to the OAB-q and is not recommended as a replacement for the standard questionnaires, such as the OAB-q and the OAB-v8. The OAB-v3 should only be used in large screening populations where there are time limits. © 2015 The Authors Journal of Obstetrics and Gynaecology Research © 2015 Japan Society of Obstetrics and Gynecology.

  20. Auscultation des barrages en beton par ecoute microsismique: Detectabilite et localisation des evenements

    NASA Astrophysics Data System (ADS)

    Giroux, Bernard

    The aging of dams leads to their degradation and is therefore a threat to normal operation, and is potentially dangerous. Ideally, a method continuously monitoring the majority of the structure would help considerably the management of operations. The feasibility of such a technique is the topic of this thesis. The principle underlying the proposed method is to listen to microseismic events generated by the cracking of the concrete dam. A method based on this principle is used to detect and attempt to predict rockbursts in the mining industry. The method procedure is the following: given a sensor network distributed over a dam, one wishes to detect the microseismic events emitted by structure cracking, to locate the source in space and time, and ultimately to characterize the stress field causing the emission. The seismic quality factor Q is usually used to quantify attenuation. Presented is a technique to reduce the noise bias in the calculation of the amplitude spectrum ratio. The results so obtained show a Q factor of order ranging from 5 to 10. A new method using genetic algorithms is presented to evaluate Q and the coupling jointly. According to our results, sensor coupling varies from 0,2 to 0,8. The corresponding Q factor attains a value of 60. Also, the ambient noise level must be known in order to establish from which distance the seismic energy can be measured. Reference RMS values of 10-5 m/s for velocity and 10-1 m/s 2 for acceleration are used as an upper limit for the computation of a so-called "critical detection radius". Thirdly, the seismic responses of circular cracks having areas of 0,01, 0,1 and 1,0 m2 were computed for a model equivalent to the Carillon Dam, for Q values varying from 5 to 100. Considering that an adequate coupling can be obtained (equivalent to Q = 50) and that a signal to noise ratio of 100 allows for the detection of the seismic signal, one can expect to detect an event caused by a 0,01 m 2 defect at a distance of 25 m. In the second part of this work, a method for locating the seismic sources based on the joint hypocenter-velocity inversion of traveltime data is presented. The inversion method relies on raytrace forward modeling. This method was tested and implemented in the inversion code. Finally, tests with synthetic data were conducted to assess the performance of the inversion program. The results show that an accurate location is achieved with about ten sensors, provided that some sensors are placed at the upstream base of the structure, the remainder being on the crest and downstream side of the dam. (Abstract shortened by UMI.)

  1. Ultra-high Q terahertz whispering-gallery modes in a silicon resonator

    NASA Astrophysics Data System (ADS)

    Vogt, Dominik Walter; Leonhardt, Rainer

    2018-05-01

    We report on the first experimental demonstration of terahertz (THz) whispering-gallery modes (WGMs) with an ultra-high quality factor of 1.5 × 104 at 0.62 THz. The WGMs are observed in a high resistivity float zone silicon spherical resonator coupled to a sub-wavelength silica waveguide. A detailed analysis of the coherent continuous wave THz spectroscopy measurements combined with a numerical model based on Mie-Debye-Aden-Kerker theory allows us to unambiguously identify the observed higher order radial THz WGMs.

  2. Simple Optoelectronic Feedback in Microwave Oscillators

    NASA Technical Reports Server (NTRS)

    Maleki, Lute; Iltchenko, Vladimir

    2009-01-01

    A proposed method of stabilizing microwave and millimeter-wave oscillators calls for the use of feedback in optoelectronic delay lines characterized by high values of the resonance quality factor (Q). The method would extend the applicability of optoelectronic feedback beyond the previously reported class of optoelectronic oscillators that comprise two-port electronic amplifiers in closed loops with high-Q feedback circuits.

  3. Associations of Circulating Growth Differentiation Factor-15 and ST2 Concentrations With Subclinical Vascular Brain Injury and Incident Stroke.

    PubMed

    Andersson, Charlotte; Preis, Sarah R; Beiser, Alexa; DeCarli, Charles; Wollert, Kai C; Wang, Thomas J; Januzzi, James L; Vasan, Ramachandran S; Seshadri, Sudha

    2015-09-01

    Growth differentiation factor-15 (GDF-15) and soluble (s)ST2 are markers of cardiac and vascular stress. We investigated the associations between circulating concentrations of these biomarkers and incident stroke and subclinical vascular brain injury in a sample from the Framingham Offspring cohort. We followed 3374 stroke- and dementia-free individuals (mean age, 59.0±9.7 years; 53% women) attending the Framingham Offspring sixth examination cycle 11.8±3.0 years for incident stroke. A subsample of 2463 individuals underwent brain magnetic resonance imaging and neuropsychological testing ≈4.0±1.7 years after the sixth examination. After adjustment for traditional cardiovascular risk factors, B-type natriuretic peptide, high-sensitivity C-reactive protein, and urine albumin levels, higher stress biomarker levels were associated cross-sectionally with lower brain volumes (β coefficients for intracranial volume comparing fourth [Q4] versus first biomarker [Q1] quartiles: -0.71% for GDF-15; P=0.002 and 0.47% for sST2; P=0.02) and worse performance on the visual reproduction test (β coefficients for Q4 versus Q1: -0.62 for GDF-15; P=0.009 and -0.40 for sST2; P=0.04). Higher GDF-15 concentrations were also associated with greater log-transformed white-matter hyperintensity volumes (β for Q4 versus Q1=0.19; P=0.01). Prospectively, a total of 203 (6%) individuals developed incident stroke/transient ischemic attack during follow-up. After multivariable adjustment, sST2 remained significantly associated with stroke/transient ischemic attack, hazard ratio for Q4 versus Q1 of 1.76, 95% confidence interval of 1.06 to 2.92, and P=0.03. Circulating GDF-15 and sST2 are associated with subclinical brain injury and cognitive impairment. Higher sST2 concentrations are also associated with incident stroke, suggesting potential links between cardiac stress biomarkers and brain injury. © 2015 American Heart Association, Inc.

  4. Size dependence of vortex-type spin torque oscillation in a Co2Fe0.4Mn0.6Si Heusler alloy disk

    NASA Astrophysics Data System (ADS)

    Seki, T.; Kubota, T.; Yamamoto, T.; Takanashi, K.

    2018-02-01

    This paper reports the systematic investigation of vortex-type spin torque oscillation in circular disks of highly spin-polarized Co2Fe0.4Mn0.6Si (CFMS) Heusler alloys. We fabricated the current-perpendicular-to-plane giant magnetoresistance (CPP-GMR) devices with various disk diameters (D) using the layer stack of CFMS/Ag3Mg/CFMS. The gyrotropic motion of the vortex core was successfully excited for the CFMS circular disks with 0.2 µm  ⩽  D  ⩽  0.3 µm. The CPP-GMR device with D  =  0.2 µm exhibited the Q factor of more than 5000 and the large output power of 0.4 nW owing to the high coherency of vortex dynamics and the high spin-polarization of CFMS. However, the Q factor was remarkably decreased as D was reduced from 0.2 µm to 0.14 µm. The comparison with the calculated resonance frequencies suggested that this degradation of the Q factor was due to the transition of the oscillation mode from the vortex mode to other modes such as the low-coherent out-of-plane precession mode. The present experimental results also suggest that there exists an adequate disk size for the enhanced Q factor of the vortex-type spin torque oscillation.

  5. Quality correction factors of composite IMRT beam deliveries: theoretical considerations.

    PubMed

    Bouchard, Hugo

    2012-11-01

    In the scope of intensity modulated radiation therapy (IMRT) dosimetry using ionization chambers, quality correction factors of plan-class-specific reference (PCSR) fields are theoretically investigated. The symmetry of the problem is studied to provide recommendable criteria for composite beam deliveries where correction factors are minimal and also to establish a theoretical limit for PCSR delivery k(Q) factors. The concept of virtual symmetric collapsed (VSC) beam, being associated to a given modulated composite delivery, is defined in the scope of this investigation. Under symmetrical measurement conditions, any composite delivery has the property of having a k(Q) factor identical to its associated VSC beam. Using this concept of VSC, a fundamental property of IMRT k(Q) factors is demonstrated in the form of a theorem. The sensitivity to the conditions required by the theorem is thoroughly examined. The theorem states that if a composite modulated beam delivery produces a uniform dose distribution in a volume V(cyl) which is symmetric with the cylindrical delivery and all beams fulfills two conditions in V(cyl): (1) the dose modulation function is unchanged along the beam axis, and (2) the dose gradient in the beam direction is constant for a given lateral position; then its associated VSC beam produces no lateral dose gradient in V(cyl), no matter what beam modulation or gantry angles are being used. The examination of the conditions required by the theorem lead to the following results. The effect of the depth-dose gradient not being perfectly constant with depth on the VSC beam lateral dose gradient is found negligible. The effect of the dose modulation function being degraded with depth on the VSC beam lateral dose gradient is found to be only related to scatter and beam hardening, as the theorem holds also for diverging beams. The use of the symmetry of the problem in the present paper leads to a valuable theorem showing that k(Q) factors of composite IMRT beam deliveries are close to unity under specific conditions. The theoretical limit k(Q(pcsr),Q(msr) ) (f(pcsr),f(msr) )=1 is determined based on the property of PCSR deliveries to provide a uniform dose in the target volume. The present approach explains recent experimental observations and proposes ideal conditions for IMRT reference dosimetry. The result of this study could potentially serve as a theoretical basis for reference dosimetry of composite IMRT beam deliveries or for routine IMRT quality assurance.

  6. Quality-adjusted survival with combination nal-IRI+5-FU/LV vs 5-FU/LV alone in metastatic pancreatic cancer patients previously treated with gemcitabine-based therapy: a Q-TWiST analysis.

    PubMed

    Pelzer, Uwe; Blanc, Jean-Frédéric; Melisi, Davide; Cubillo, Antonio; Von Hoff, Daniel D; Wang-Gillam, Andrea; Chen, Li-Tzong; Siveke, Jens T; Wan, Yin; Solem, Caitlyn T; Botteman, Marc F; Yang, Yoojung; de Jong, Floris A; Hubner, Richard A

    2017-05-09

    In the NAPOLI-1 Phase 3 trial, nal-IRI+5-fluorouracil and leucovorin (5-FU/LV) significantly improved median overall survival (6.1 vs 4.2 months, P=0.012) and progression-free survival (3.1 vs 1.5 months, P=0.0001) vs 5-FU/LV alone in metastatic pancreatic adenocarcinoma patients previously treated with gemcitabine-based therapy. This analysis evaluated between treatment differences in quality-adjusted time without symptoms of disease progression or toxicity (Q-TWiST). Overall survival was partitioned into time with grade ⩾3 toxicity (TOX), disease progression (REL), and time without disease progression symptoms or grade ⩾3 toxicity (TWiST). Mean Q-TWiST was calculated by weighting time spent by a utility of 1.0 for TWiST and 0.5 for TOX and REL. In threshold analyses, utility for TOX and REL were varied from 0.0 to 1.0. Patients in nal-IRI+5-FU/LV (n=117) vs 5-FU/LV (n=119) had significantly more mean time in TWiST (3.4 vs 2.4 months) and TOX (1.0 vs 0.3 months) but similar REL (2.5 vs 2.7 months). In the base case, nal-IRI+5-FU/LV patients had 1.3 months (95% CI, 0.4-2.1; 5.1 vs 3.9) greater Q-TWiST (threshold analyses range: 0.9-1.6 months). Within NAPOLI-1, nal-IRI+5-FU/LV resulted in statistically significant and clinically meaningful gains in quality-adjusted survival vs 5-FU/LV alone.

  7. Discovery and identification of quality markers of Chinese medicine based on pharmacokinetic analysis.

    PubMed

    He, Jun; Feng, Xinchi; Wang, Kai; Liu, Changxiao; Qiu, Feng

    2018-02-28

    Quality control of Chinese medicine (CM) is an effective measure to ensure the safety and efficacy of CM in clinical practice, which is also a key factor to restrict the modernization process of CM. Various chemical components exist in CM and the determination of several chemical components is the main approach for quality control of vast majority of CM in the present. However, many components determined lack not only specificity, but also biological activities. This is bound to greatly reduce the actual value of quality standard of CM. Professor Changxiao Liu proposed the "quality marker" (Q-marker) concept to ensure the standardization and rationalization for the quality control of CM. As we all know, CMs are taken orally in most cases and could be extensively metabolized in vivo. Both prototype components and the metabolites could be the actual therapeutic material basis. Pharmacokinetic studies could benefit the elucidation of actual therapeutic material basis which is closely related to the identification of Q-markers. Therefore, a new strategy about Q-marker was proposed based on the pharmacokinetic analysis of CM, hoping to provide some ideas for the discovery and identification of Q-marker. The relationship between pharmacokinetic studies and the identification of Q-markers was demonstrated in this review and a new strategy was proposed. Starting from the pharmacokinetic analysis, reverse tracing of the prototype active components and the potential prodrugs in CM were conducted first and the therapeutic material basis were identified as Q-markers. Then, modern analytical techniques and methods were applied to obtain comprehensive quality control for these constituents. Several CMs including gingko biloba, ginseng, Periplocae Cortex, Mori Cortex, Bupleuri Radix and Scutellariae Radix were listed as examples to clarify how the new strategy could be applied. Pharmacokinetic studies play an important role for the elucidation of therapeutic material basis of CM and the identification of Q-markers and it should be taken into account during the process of the investigation of Q-marker. Copyright © 2018 Elsevier GmbH. All rights reserved.

  8. High permittivity and low loss ceramics in the BaO-SrO-Nb{sub 2}O{sub 5} system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sreemoolanadhan, H.; Sebastian, M.T.; Mohanan, P.

    1995-06-01

    A new group of compounds with composition (Ba{sub 5{minus}X}Sr{sub x})Nb{sub 4}O{sub 15}, having high permittivity and low loss have been prepared and characterized in the microwave frequency region. X-ray diffraction studies showed that monophase compound existed for all values of x from 0 to 5. Microwave dielectric properties such as {var_epsilon}{sub r} and {tau}{sub f} showed smooth variation with x, while the unloaded quality factor (Q{sub u}) showed remarkable improvement with x. A range of ceramic dielectric resonators (DR) with 40 < {var_epsilon}{sub r} < 50, {minus}10 < {tau}{sub f} < +10 and Q {times} f > 10,000 can bemore » obtained in this system.« less

  9. Measurement of the Elastic Ep Cross Section at Q2 = 0.66, 1.10, 1.51 and 1.65 Gev2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Yang

    The nucleon form factors have been investigated by physicists for decades because of their fundamental importance. The world data of the proton magnetic form factor GMp has been focused on Q2 lower than 5 GeV2 and they have large uncertainties at higher Q2. Jefferson Lab experiment E12-07-108 aims to improve the accuracy of the e ? p elastic cross section to better than 2% over a Q2 range of 7 ? 14 GeV2. From 2015 to 2016, the e ? p elastic cross section was measured over a wide range of Q2 from 0.66 ? 12.56 GeV2 at the Thomasmore » Jefferson National Accelerator Facility in Virginia, USA. An unpolarized electron beam was scattered o? a cryogenic hydrogen target and the scattered electron was detected in the high resolution spectrometers. This thesis focuses on the cross section calculations of the data taken in the spring of 2015, where Q2 = 0.66, 1.10, 1.51 and 1.66 GeV2. At Q2 = 0.66 GeV2, an uncertainty < 3% was achieved and < 5% was achieved for the other three Q2 at the moment. The results were compared with the world data and the good agreement provides confidence for the experimental measurements at higher Q2.« less

  10. Do stressed mothers have heavier children?: A meta-analysis on the relationship between maternal stress and child body mass index

    PubMed Central

    Tate, Eleanor B.; Wood, Wendy; Liao, Yue; Dunton, Genevieve F.

    2015-01-01

    Child obesity continues to be a prevalent public health issue. This meta-analysis synthesized 17 studies investigating the association between levels of psychological stress experienced by mothers and the body mass index of their children. The overall standardized mean difference effect size was positive and significantly different from zero in cross-sectional d = 0.20 [k = 14, 95% Confidence Interval (CI): 0.06, 0.34] and longitudinal studies d = 0.18 (k = 5, 95% CI: 0.00, 0.351), and had significant heterogeneity in both [cross-sectional, Q(13) = 193.00, p < 0.001; longitudinal, Q(4) = 29.46, p < 0.001]. In longitudinal studies, effect sizes were larger when children also would have experienced the stressor, Q(6) = 4.68, p < 0.05, for toddlers than infants, Q(4) = 5.04, p < 0.05, and in higher quality studies, Q(4) = 14.58, p < 0.05. Results highlight the potential benefits of including a parent stress management component in childhood obesity prevention programs. PMID:25879393

  11. Dielectric and piezoelectric properties of CeO2-added nonstoichiometric (Na0.5K0.5)0.97(Nb0.96Sb0.04)O3 ceramics for piezoelectric energy harvesting device applications.

    PubMed

    Oh, Youngkwang; Noh, Jungrae; Yoo, Juhyun; Kang, Jinhee; Hwang, Larkhoon; Hong, Jaeil

    2011-09-01

    In this study, nonstoichiometric (Na(0.5)K(0.5))(0.97)(Nb(0.96)Sb(0.04))O(3) ceramics were fabricated and their dielectric and piezoelectric properties were investigated according to the CeO(2) addition. In this ceramic composition, CeO(2) addition improved sinterability, electromechanical coupling factor k(p), mechanical quality factor Q(m), piezoelectric constant d(33), and g(33). At the sintering temperature of 1100°C, for the 0.2wt% CeO(2) added specimen, the optimum values of density = 4.359 g/cm(3), k(p) = 0.443, Q(m) = 588, ε(r) = 444, d(33) = 159 pC/N, and g(33) = 35 × 10(-3) V·m/N, were obtained. A piezoelectric energy harvesting device using 0.2 wt% CeO(2)- added lead-free (K(0.5)Na(0.5))(0.97)(Nb(0.96)Sb(0.04))O(3) ceramics and a rectifying circuit for energy harvesting were fabricated and their electrical characteristics were investigated. Under an external vibration acceleration of 0.7 g, when the mass, the frequency of vibration generator, and matching load resistance were 2.4 g, 70 Hz, and 721 Ω, respectively, output voltage and power of piezoelectric harvesting device indicated the optimum values of 24.6 mV(rms) and 0.839 μW, respectively-suitable for application as the electric power source of a ubiquitous sensor network (USN) sensor node.

  12. Computing the nucleon charge and axial radii directly at Q2=0 in lattice QCD

    NASA Astrophysics Data System (ADS)

    Hasan, Nesreen; Green, Jeremy; Meinel, Stefan; Engelhardt, Michael; Krieg, Stefan; Negele, John; Pochinsky, Andrew; Syritsyn, Sergey

    2018-02-01

    We describe a procedure for extracting momentum derivatives of nucleon matrix elements on the lattice directly at Q2=0 . This is based on the Rome method for computing momentum derivatives of quark propagators. We apply this procedure to extract the nucleon isovector magnetic moment and charge radius as well as the isovector induced pseudoscalar form factor at Q2=0 and the axial radius. For comparison, we also determine these quantities with the traditional approach of computing the corresponding form factors, i.e. GEv(Q2) and GMv(Q2) for the case of the vector current and GPv(Q2) and GAv(Q2) for the axial current, at multiple Q2 values followed by z -expansion fits. We perform our calculations at the physical pion mass using a 2HEX-smeared Wilson-clover action. To control the effects of excited-state contamination, the calculations were done at three source-sink separations and the summation method was used. The derivative method produces results consistent with those from the traditional approach but with larger statistical uncertainties especially for the isovector charge and axial radii.

  13. Q-TWiST analysis comparing ipilimumab/dacarbazine vs placebo/dacarbazine for patients with stage III/IV melanoma

    PubMed Central

    Sherrill, B; Wang, J; Kotapati, S; Chin, K

    2013-01-01

    Background: Study CA184024 was a multinational, randomised, double-blind, phase 3 study comparing ipilimumab/dacarbazine (DTIC) vs placebo/DTIC in patients with untreated stage III/IV melanoma, which showed that ipilimumab significantly improves survival in patients with metastatic melanoma. The objective of this analysis was to compare the quality-adjusted survival experience among patients in this trial. Methods: Survival time was partitioned into health states: toxicity, time before progression without toxicity, and relapse until death or end of follow-up. Q-TWiST (quality-adjusted time without symptoms of disease or toxicity of treatment) was calculated as the utility-weighted sum of the mean health state durations. Analyses were repeated over extended follow-up periods. Results: Based on a combination of trial-based and external utility scores, the Q-TWiST difference in this trial was 0.50 months (P=0.0326) favoring ipilimumab after 1 year. The Q-TWiST difference was 1.5 months with 2 years of follow-up (P=0.0091), 2.36 months at 3 years (P=0.005) and 3.28 months at 4 years (P=0.0074). Conclusion: During the first year of study, there was little difference between groups in quality-adjusted survival. However, after 2, 3 and 4 years follow-up for patients with extended survival, the benefits of IPI+DTIC vs PLA+DTIC for advanced melanoma continue to accrue. PMID:23787916

  14. Beneficial effects of aged garlic extract and coenzyme Q10 on vascular elasticity and endothelial function: The FAITH randomized clinical trial

    PubMed Central

    Larijani, Vahid Nabavi; Ahmadi, Naser; Zeb, Irfan; Khan, Faraz; Flores, Ferdinand; Budoff, Matthew

    2014-01-01

    Objective Aged garlic extract (AGE) is associated with a significant decrease in atherosclerotic plaque progression and endothelial function improvement. Similarly, coenzyme Q10 (CoQ10) has significant beneficial effects on endothelial function. A stressful lifestyle is a well-known risk factor for the presence and progression of atherosclerosis. This study investigated the effect of AGE plus CoQ10 on vascular elasticity measured by pulse-wave velocity (PWV) and endothelial function measured by digital thermal monitoring (DTM) in firefighters. Methods Sixty-five Los-Angeles County firefighters who met the eligibility criteria were enrolled in this placebo-controlled, double-blinded randomized trial. The firefighters were randomized to four tablets of AGE (300 mg/tablet) plus CoQ10 (30 mg/tablet) or placebo. The participants underwent quarterly visits and 1-year follow-up. PWV and DTM were measured at baseline and at the 1-year follow-up. Results There were no significant differences in age, cardiovascular risk factors, PWV, and DTM between the AGE/CoQ10 and placebo groups at baseline (P > 0.5). At 1-y, PWV and DTM significantly improved in the AGE/CoQ10 compared with the placebo group (P < 0.05). After an adjustment for cardiovascular risk factors and statin therapy, the mean decrease in vascular stiffness (PWV) was 1.21 m/s in the AGE/CoQ10 compared with the placebo group (P = 0.005). Similarly, the mean increase in the area under the temperature curve, the DTM index of endothelial function, was 31.3 in the AGE/CoQ10 compared with the placebo group (P = 0.01). Conclusion The combination of AGE and CoQ10 was independently associated with significant beneficial effects on vascular elasticity and endothelial function in firefighters with high occupational stress, highlighting the important role of AGE and CoQ10 in atherosclerotic prevention of such individuals. PMID:22858191

  15. Questionnaire development and validity to measure sexual intention among youth in Malaysia.

    PubMed

    Muhammad, Noor Azimah; Shamsuddin, Khadijah; Mohd Amin, Rahmah; Omar, Khairani; Thurasamy, Ramayah

    2017-02-02

    From the Theory of Planned Behaviour perspective, sexual intention is determined by a permissive attitude, perception of social norms and perceived self-efficacy in performing sexual activity. The aim of this study was to develop and validate the Youth Sexual Intention Questionnaire (YSI-Q), which was designed to measure sexual intention among youths in Malaysia. A total of 25 items were developed based on literature reviews encompassing four main constructs: sexual intention, attitude, social norms and self-efficacy. The YSI-Q then underwent a validation process that included content and face validity, exploratory factor analysis (EFA), reliability analysis, and confirmatory factor analysis (CFA). This study was conducted on unmarried youths aged 18 to 22 years who were studying in colleges around Klang Valley, Malaysia. EFA supported the four factor structure, but five items were removed due to incorrect placement or low factor loading (<0.60). Internal reliability using Cronbach's alpha ranged between 0.89 and 0.94. The CFA further confirmed the construct, convergent and discriminant validity of the YSI-Q with χ 2  = 392.43, df = 164, p < 0.001, χ 2 /df = 2.40, CFI = 0.93 and TLI = 0.92 and RMSEA = 0.08. The final set of YSI-Q consisted of 20 items measuring sexual intention (five items), attitude (five items), social norms (six items) and self-efficacy (four items) of practicing sexual activity. YSI-Q was shown to be a reliable and valid tool to be used among Malaysian youths.

  16. soil organic matter pools and quality are sensitive to global climate change in tropical forests from India

    NASA Astrophysics Data System (ADS)

    Mani, Shanmugam; Merino, Agustín; García-Oliva, Felipe; Riotte, Jean; Sukumar, Raman

    2016-04-01

    Soil organic carbon (SOC) storage and quality are some of the most important factors determining ecological process in tropical forests, which are especially sensitive to global climate change (GCC). In India, the GCC scenarios expect increasing of drought period and wildfire, which may affect the SOC, and therefore the capacity of forest for C sequestration. The aim of the study was to evaluate the amount of soil C and its quality in the mineral soil across precipitation gradient with different factors (vegetation, pH, soil texture and bedrock composition) for generate SOC predictions under GCC. Six soil samples were collected (top 10 cm depth) from 19 1-ha permanent plots in the Mudumalai Wildlife Sanctuary of southern India, which are characterised by four types of forest vegetation (i.e. dry thorn, dry deciduous, moist deciduous and semi-evergreen forest) distributed along to rainfall gradient. The driest sites are dominated by sandy soils, while the soil clay proportion increased in the wet sites. Total organic C (Leco CN analyser), and the SOM quality was assessed by Differential Scanning Calorimetry (DSC) and Solid-state 13CCP-MAS NMR analyses. Soil organic C was positively correlated with precipitation (R2 = 0.502, p<0.01) and with soil clay content (R2 =0.15, p<0.05), and negatively with soil sand content (R2=0.308, p<0.001) and with pH (R2=0.529, p<0.01); while the C/N was only found positive correlation with clay (R2= 0.350, p<0.01). The driest sites (dry thorn forest) has the lowest proportion of thermal combustion of recalcitrant organic matter (Q2,375-475 °C) than the other sites (p<0.05) and this SOC fraction correlated positively with rainfall (R2=0.27, p=0.01). The Q2 model with best fit included rainfall, pH, sand, clay, C and C/N (R2=0.52, p=0.01). Principal component analysis explains 77% of total variance. The sites on the fist component are distributed along the rainfall gradient. These results suggest that the 50% of variance was explained by precipitation and therefore vegetation type. Consequently, the drier sites has a lower C pools with a higher proportion of labile SOC fraction. As a consequence, we expect if the rainfall decreased by GCC could increase SOC mineralization, and therefore reducing the capacity of C sequestration within soil profile.

  17. Long-term dietary quality and risk of developing rheumatoid arthritis in women.

    PubMed

    Hu, Yang; Sparks, Jeffrey A; Malspeis, Susan; Costenbader, Karen H; Hu, Frank B; Karlson, Elizabeth W; Lu, Bing

    2017-08-01

    To evaluate the association between long-term dietary quality, measured by the 2010 Alternative Healthy Eating Index, and risk of rheumatoid arthritis (RA) in women. We prospectively followed 76 597 women in the Nurses' Health Study aged 30-55 years and 93 392 women in the Nurses' Health Study II aged 25-42 years at baseline and free from RA or other connective tissue diseases. The lifestyle, environmental exposure and anthropometric information were collected at baseline and updated biennially. Cumulative follow-up rates were more than 90% for both cohorts. The primary outcome was RA alone with two subtypes of the disease: seropositive and seronegative RA. During 3 678 104 person-years, 1007 RA cases were confirmed. In the multivariable-adjusted model, long-term adherence to healthy eating patterns was marginally associated with reduced RA risk. To assess potential effect modification by age at diagnosis, we stratified by age. Among women aged ≤55 years, better quality diet was associated with lower RA risk (HR Q4 vs Q1 : 0.67; 95% CI 0.51 to 0.88; p trend: 0.002), but no significant association was found for women aged >55 years (p interaction: 0.005). When stratifying by serostatus, the inverse association among those aged ≤55 years was strongest for seropositive RA (HR Q4 vs Q1 : 0.60; 95% CI 0.42 to 0.86; p trend: 0.003). A healthier diet was associated with a reduced risk of RA occurring at 55 years of age or younger, particularly seropositive RA. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  18. Design of primers and probes for quantitative real-time PCR methods.

    PubMed

    Rodríguez, Alicia; Rodríguez, Mar; Córdoba, Juan J; Andrade, María J

    2015-01-01

    Design of primers and probes is one of the most crucial factors affecting the success and quality of quantitative real-time PCR (qPCR) analyses, since an accurate and reliable quantification depends on using efficient primers and probes. Design of primers and probes should meet several criteria to find potential primers and probes for specific qPCR assays. The formation of primer-dimers and other non-specific products should be avoided or reduced. This factor is especially important when designing primers for SYBR(®) Green protocols but also in designing probes to ensure specificity of the developed qPCR protocol. To design primers and probes for qPCR, multiple software programs and websites are available being numerous of them free. These tools often consider the default requirements for primers and probes, although new research advances in primer and probe design should be progressively added to different algorithm programs. After a proper design, a precise validation of the primers and probes is necessary. Specific consideration should be taken into account when designing primers and probes for multiplex qPCR and reverse transcription qPCR (RT-qPCR). This chapter provides guidelines for the design of suitable primers and probes and their subsequent validation through the development of singlex qPCR, multiplex qPCR, and RT-qPCR protocols.

  19. A Novel High-Throughput Method for Molecular Detection of Human Pathogenic Viruses Using a Nanofluidic Real-Time PCR System

    PubMed Central

    Coudray-Meunier, Coralie; Fraisse, Audrey; Martin-Latil, Sandra; Delannoy, Sabine; Fach, Patrick; Perelle, Sylvie

    2016-01-01

    Human enteric viruses are recognized as the main causes of food- and waterborne diseases worldwide. Sensitive and quantitative detection of human enteric viruses is typically achieved through quantitative RT-PCR (RT-qPCR). A nanofluidic real-time PCR system was used to develop novel high-throughput methods for qualitative molecular detection (RT-qPCR array) and quantification of human pathogenic viruses by digital RT-PCR (RT-dPCR). The performance of high-throughput PCR methods was investigated for detecting 19 human pathogenic viruses and two main process controls used in food virology. The conventional real-time PCR system was compared to the RT-dPCR and RT-qPCR array. Based on the number of genome copies calculated by spectrophotometry, sensitivity was found to be slightly better with RT-qPCR than with RT-dPCR for 14 viruses by a factor range of from 0.3 to 1.6 log10. Conversely, sensitivity was better with RT-dPCR than with RT-qPCR for seven viruses by a factor range of from 0.10 to 1.40 log10. Interestingly, the number of genome copies determined by RT-dPCR was always from 1 to 2 log10 lower than the expected copy number calculated by RT-qPCR standard curve. The sensitivity of the RT-qPCR and RT-qPCR array assays was found to be similar for two viruses, and better with RT-qPCR than with RT-qPCR array for eighteen viruses by a factor range of from 0.7 to 3.0 log10. Conversely, sensitivity was only 0.30 log10 better with the RT-qPCR array than with conventional RT-qPCR assays for norovirus GIV detection. Finally, the RT-qPCR array and RT-dPCR assays were successfully used together to screen clinical samples and quantify pathogenic viruses. Additionally, this method made it possible to identify co-infection in clinical samples. In conclusion, given the rapidity and potential for large numbers of viral targets, this nanofluidic RT-qPCR assay should have a major impact on human pathogenic virus surveillance and outbreak investigations and is likely to be of benefit to public health. PMID:26824897

  20. Comparison of k Q factors measured with a water calorimeter in flattening filter free (FFF) and conventional flattening filter (cFF) photon beams

    NASA Astrophysics Data System (ADS)

    de Prez, Leon; de Pooter, Jacco; Jansen, Bartel; Perik, Thijs; Wittkämper, Frits

    2018-02-01

    Recently flattening filter free (FFF) beams became available for application in modern radiotherapy. There are several advantages of FFF beams over conventional flattening filtered (cFF) beams, however differences in beam spectra at the point of interest in a phantom potentially affect the ion chamber response. Beams are also non-uniform over the length of a typical reference ion chamber and recombination is usually larger. Despite several studies describing FFF beam characteristics, only a limited number of studies investigated their effect on k Q factors. Some of those studies predicted significant discrepancies in k Q factors (0.4% up to 1.0%) if TPR20,10 based codes of practice (CoPs) were to be used. This study addresses the question to which extent k Q factors, based on a TPR20,10 CoP, can be applied in clinical reference dosimetry. It is the first study that compares k Q factors measured directly with an absorbed dose to water primary standard in FFF-cFF pairs of clinical photon beams. This was done with a transportable water calorimeter described elsewhere. The measurements corrected for recombination and beam radial non-uniformity were performed in FFF-cFF beam pairs at 6 MV and 10 MV of an Elekta Versa HD for a selection of three different Farmer-type ion chambers (eight serial numbers). The ratio of measured k Q factors of the FFF-cFF beam pairs were compared with the TPR20,10 CoPs of the NCS and IAEA and the %dd(10) x CoP of the AAPM. For the TPR20,10 based CoPs differences less than 0.23% were found in k Q factors between the corresponding FFF-cFF beams with standard uncertainties smaller than 0.35%, while for the %dd(10) x these differences were smaller than 0.46% and within the expanded uncertainty of the measurements. Based on the measurements made with the equipment described in this study the authors conclude that the k Q factors provided by the NCS-18 and IAEA TRS-398 codes of practice can be applied for flattening filter free beams without additional correction. However, existing codes of practice cannot be applied ignoring the significant volume averaging effect of the FFF beams over the ion chamber cavity. For this a corresponding volume averaging correction must be applied.

  1. Exposure to movie smoking: its relation to smoking initiation among US adolescents.

    PubMed

    Sargent, James D; Beach, Michael L; Adachi-Mejia, Anna M; Gibson, Jennifer J; Titus-Ernstoff, Linda T; Carusi, Charles P; Swain, Susan D; Heatherton, Todd F; Dalton, Madeline A

    2005-11-01

    Regional studies have linked exposure to movie smoking with adolescent smoking. We examined this association in a representative US sample. We conducted a random-digit-dial survey of 6522 US adolescents aged 10 to 14 years. Using previously validated methods, we estimated exposure to movie smoking, in 532 recent box-office hits, and examined its relation with adolescents having ever tried smoking a cigarette. The distributions of demographics and census region in the unweighted sample were almost identical to 2000 US Census estimates, confirming representativeness. Overall, 10% of the population had tried smoking. Quartile (Q) of movie smoking exposure was significantly associated with the prevalence of smoking initiation: 0.02 of adolescents in Q1 had tried smoking; 0.06 in Q2; 0.11 in Q3; and 0.22 in Q4. This association did not differ significantly by race/ethnicity or census region. After controlling for sociodemographics, friend/sibling/parent smoking, school performance, personality characteristics, and parenting style, the adjusted odds ratio for having tried smoking were 1.7 (95% confidence interval [CI]: 1.1, 2.7) for Q2, 1.8 (95% CI: 1.2, 2.9) for Q3, and 2.6 (95% CI: 1.7, 4.1) for Q4 compared with adolescents in Q1. The covariate-adjusted attributable fraction was 0.38 (95% CI: 0.20, 0.56), suggesting that exposure to movie smoking is the primary independent risk factor for smoking initiation in US adolescents in this age group. Smoking in movies is a risk factor for smoking initiation among US adolescents. Limiting exposure of young adolescents to movie smoking could have important public health implications.

  2. Applicability of the ReproQ client experiences questionnaire for quality improvement in maternity care

    PubMed Central

    Scheerhagen, Marisja; Tholhuijsen, Dominique J.C.; Birnie, Erwin; Franx, Arie; Bonsel, Gouke J.

    2016-01-01

    Background. The ReproQuestionnaire (ReproQ) measures the client’s experience with maternity care, following the WHO responsiveness model. In 2015, the ReproQ was appointed as national client experience questionnaire and will be added to the national list of indicators in maternity care. For using the ReproQ in quality improvement, the questionnaire should be able to identify best and worst practices. To achieve this, ReproQ should be reliable and able to identify relevant differences. Methods and Findings. We sent questionnaires to 17,867 women six weeks after labor (response 32%). Additionally, we invited 915 women for the retest (response 29%). Next we determined the test–retest reliability, the Minimally Important Difference (MID) and six known group comparisons, using two scorings methods: the percentage women with at least one negative experience and the mean score. The reliability for the percentage negative experience and mean score was both ‘good’ (Absolute agreement = 79%; intraclass correlation coefficient = 0.78). The MID was 11% for the percentage negative and 0.15 for the mean score. Application of the MIDs revealed relevant differences in women’s experience with regard to professional continuity, setting continuity and having travel time. Conclusions. The measurement characteristics of the ReproQ support its use in quality improvement cycle. Test–retest reliability was good, and the observed minimal important difference allows for discrimination of good and poor performers, also at the level of specific features of performance. PMID:27478690

  3. Treatment of pseudobulbar affect in ALS with dextromethorphan/quinidine: a randomized trial.

    PubMed

    Brooks, B R; Thisted, R A; Appel, S H; Bradley, W G; Olney, R K; Berg, J E; Pope, L E; Smith, R A

    2004-10-26

    Patients with ALS commonly exhibit pseudobulbar affect. The authors conducted a multicenter, randomized, double-blind, controlled, parallel, three-arm study to test a defined combination of dextromethorphan hydrobromide (DM) and quinidine sulfate (Q) (AVP-923) for the treatment of pseudobulbar affect in ALS. Q inhibits the rapid first-pass metabolism of DM. The effects of AVP-923 (30 mg of DM plus 30 mg of Q) given twice daily for 28 days were compared with those of its components. Patients were evaluated on days 1, 15, and 29. The primary efficacy variable was the change from baseline in the Center for Neurologic Study Lability Scale (CNS-LS) score. Secondary efficacy variables were laughing/crying episode rates and changes in Visual Analog Scales for Quality of Life (QOL) and Relationships (QOR). Efficacy was evaluated in intention-to-treat subjects who were not poor metabolizers of DM (n = 65 for AVP-923, n = 30 for DM, and n = 34 for Q). Safety was assessed in all randomized subjects (n = 140). AVP-923 patients experienced 3.3-point greater improvements in CNS-LS than DM patients (p = 0.001) and 3.7-point greater improvements than Q patients (p < 0.001). AVP-923 patients exhibited lower overall episode rates, improved QOL scores, and improved QOR scores (p < 0.01 for all endpoints). Adverse effects were mostly mild or moderate; treatment-related discontinuation was 24% for AVP-923, 6% for DM, and 8% for Q. AVP-923 palliates pseudobulbar affect in ALS. Overall benefits of treatment are reflected in fewer episodes of crying and laughing and improvements in overall quality of life and quality of relationships.

  4. A genome-wide linkage scan for dietary energy and nutrient intakes: the Health, Risk Factors, Exercise Training, and Genetics (HERITAGE) Family Study.

    PubMed

    Collaku, Agron; Rankinen, Tuomo; Rice, Treva; Leon, Arthur S; Rao, D C; Skinner, James S; Wilmore, Jack H; Bouchard, Claude

    2004-05-01

    A poor diet is a risk factor for chronic diseases such as obesity, cardiovascular disease, hypertension, and some cancers. Twin and family studies suggest that genetic factors potentially influence energy and nutrient intakes. We sought to identify genomic regions harboring genes affecting total energy, carbohydrate, protein, and fat intakes. We performed a genomic scan in 347 white sibling pairs and 99 black sibling pairs. Dietary energy and nutrient intakes were assessed by using Willett's food-frequency questionnaire. Single-point and multipoint Haseman-Elston regression techniques were used to test for linkage. These subjects were part of the Health, Risk Factors, Exercise Training, and Genetics (HERITAGE) Family Study, a multicenter project undertaken by 5 laboratories. In the whites, the strongest evidence of linkage appeared for dietary energy and nutrient intakes on chromosomes 1p21.2 (P = 0.0002) and 20q13.13 (P = 0.00007), and that for fat intake appeared on chromosome 12q14.1 (P = 0.0013). The linkage evidence on chromosomes 1 and 20 related to total energy intake rather than to the intake of specific macronutrients. In the blacks, promising linkages for macronutrient intakes occurred on chromosomes 12q23-q24.21, 1q32.1, and 7q11.1. Several potential candidate genes are encoded in and around the linkage regions on chromosomes 1p21.2, 12q14.1, and 20q13.13. These are the first reported human quantitative trait loci for dietary energy and macronutrient intakes. Further study may refine these quantitative trait loci to identify potential candidate genes for energy and specific macronutrient intakes that would be amenable to more detailed molecular studies.

  5. Coxiella burnetii seroprevalence and associated risk factors in dairy and mixed cattle farms from Ecuador.

    PubMed

    Carbonero, Alfonso; Guzmán, Lucía T; Montaño, Karen; Torralbo, Alicia; Arenas-Montes, Antonio; Saa, Luis R

    2015-03-01

    Q fever is a zoonotic disease caused by Coxiella burnetii, a bacterial agent for which ruminants are the main reservoir. An extensive cross-sectional study to determine the seroprevalence of and associated risk factors for Q fever was performed in dairy and mixed (dairy-beef) cattle herds in Ecuador. A total of 2668 serum samples from 386 herds were analyzed using an ELISA. In addition, a questionnaire with 57 variables related to management, feeding, facilities, biosecurity and animal health was completed for every cattle farm. A Generalized Estimating Equations model was used to determine the factors associated with C. burnetii seropositivity. The true prevalence of C. burnetii seropositivity in dairy and mixed cattle from Ecuador reached 12.6% (CI95%: 11.3-13.9%). The herd prevalence was 46.9% (181/386) (CI95%: 41.9-51.9%), and the within herd prevalence ranged between 8% and 100% (mean: 25.0%; Q1: 12.5%, Q2: 25.0%, Q3: 37.5%). Four factors were included in the GEE model for C. burnetii seropositivity: age of the cattle (OR: 1.01; CI95%: 1.006-1.014), feeding of calves with milk replacers (OR: 1.94; CI95%: 1.1-3.3), bovine respiratory syncytial virus seropositivity (OR: 1.54; CI95%: 1.1-2.3), and disinfection of the umbilical cord (OR: 0.60; CI95%: 0.4-0.9). Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Index to Estimate the Efficiency of an Ophthalmic Practice.

    PubMed

    Chen, Andrew; Kim, Eun Ah; Aigner, Dennis J; Afifi, Abdelmonem; Caprioli, Joseph

    2015-08-01

    A metric of efficiency, a function of the ratio of quality to cost per patient, will allow the health care system to better measure the impact of specific reforms and compare the effectiveness of each. To develop and evaluate an efficiency index that estimates the performance of an ophthalmologist's practice as a function of cost, number of patients receiving care, and quality of care. Retrospective review of 36 ophthalmology subspecialty practices from October 2011 to September 2012 at a university-based eye institute. The efficiency index (E) was defined as a function of adjusted number of patients (N(a)), total practice adjusted costs (C(a)), and a preliminary measure of quality (Q). Constant b limits E between 0 and 1. Constant y modifies the influence of Q on E. Relative value units and geographic cost indices determined by the Centers for Medicare and Medicaid for 2012 were used to calculate adjusted costs. The efficiency index is expressed as the following: E = b(N(a)/C(a))Q(y). Independent, masked auditors reviewed 20 random patient medical records for each practice and filled out 3 questionnaires to obtain a process-based quality measure. The adjusted number of patients, adjusted costs, quality, and efficiency index were calculated for 36 ophthalmology subspecialties. The median adjusted number of patients was 5516 (interquartile range, 3450-11,863), the median adjusted cost was 1.34 (interquartile range, 0.99-1.96), the median quality was 0.89 (interquartile range, 0.79-0.91), and the median value of the efficiency index was 0.26 (interquartile range, 0.08-0.42). The described efficiency index is a metric that provides a broad overview of performance for a variety of ophthalmology specialties as estimated by resources used and a preliminary measure of quality of care provided. The results of the efficiency index could be used in future investigations to determine its sensitivity to detect the impact of interventions on a practice such as training modules or practice restructuring.

  7. Dietary acid load and chronic kidney disease in elderly adults: Protein and potassium intake.

    PubMed

    Ko, Byung-Joon; Chang, Yoosoo; Ryu, Seungho; Kim, Eun Mi; Lee, Mi Yeon; Hyun, Young Youl; Lee, Kyu-Beck

    2017-01-01

    Dietary net endogenous acid production (NEAP), which represents total dietary load of nonvolatile acid, may affect kidney function. Estimated NEAP (eNEAP) is calculated indirectly by the ratio of protein and potassium intake. A few studies are available assessing the association between eNEAP and chronic kidney disease (CKD), and its relation to dietary protein and potassium intake in the elderly. A total 1,369 community-dwelling elderly Koreans in the Kangbuk Samsung Cohort Study (KSCS) were evaluated using a food frequency questionnaire (FFQ) and comprehensive health examination. We evaluated the association between eNEAP and the CKD. We also examined their relation to protein and potassium intake. eNEAP was correlated with potassium intake (r = -0.410, P < 0.001), but was not correlated with protein intake (r = -0.004, P = 0.879). In a full multivariate adjustment for sociodemographic factors, dietary factors, and comorbidities, the participants with higher eNEAP quartiles (Q2, Q3, Q4) had higher odds of CKD compared to the lowest eNEAP quartile (Q1); OR (95% CI) were 1.47 (0.78-2.72), 1.66 (0.85-3.23), and 2.30 (1.16-4.60) respectively (P for trend = 0.019). The odds of CKD decreased for participants with higher potassium intake quartiles (Q2, Q3, Q4) compared to the lowest potassium intake quartile (Q1); OR (95% CI) were 0.52 (0.28-0.95), 0.50 (0.26-0.96), and 0.50 (0.21-0.99) respectively (P for trend = 0.050). Protein intake was not associated with CKD. The association between eNEAP and CKD was similar in subgroup analysis. Dietary acid load was associated with CKD. Among the nutrients related to dietary acid load, potassium intake was negatively associated with CKD, but protein intake was not associated with CKD in elderly adults.

  8. Light-meson masses in an unquenched quark model

    NASA Astrophysics Data System (ADS)

    Chen, Xiaoyun; Ping, Jialun; Roberts, Craig D.; Segovia, Jorge

    2018-05-01

    We perform a coupled-channels calculation of the masses of light mesons with the quantum numbers I JP =-, (I ,J )=0 , 1, by including q q ¯ and (q q ¯)2 components in a nonrelativistic chiral quark model. The coupling between two- and four-quark configurations is realized through a 3P0 quark-pair creation model. With the usual form of this operator, the mass shifts are large and negative, an outcome which raises serious issues of validity for the quenched quark model. Herein, therefore, we introduce some improvements of the 3P0 operator in order to reduce the size of the mass shifts. By introducing two simple factors, physically well motivated, the coupling between q q ¯ and (q q ¯)2 components is weakened, producing mass shifts that are around 10%-20% of hadron bare masses.

  9. Prediction of blood-brain partitioning: a model based on molecular electronegativity distance vector descriptors.

    PubMed

    Zhang, Yong-Hong; Xia, Zhi-Ning; Qin, Li-Tang; Liu, Shu-Shen

    2010-09-01

    The objective of this paper is to build a reliable model based on the molecular electronegativity distance vector (MEDV) descriptors for predicting the blood-brain barrier (BBB) permeability and to reveal the effects of the molecular structural segments on the BBB permeability. Using 70 structurally diverse compounds, the partial least squares regression (PLSR) models between the BBB permeability and the MEDV descriptors were developed and validated by the variable selection and modeling based on prediction (VSMP) technique. The estimation ability, stability, and predictive power of a model are evaluated by the estimated correlation coefficient (r), leave-one-out (LOO) cross-validation correlation coefficient (q), and predictive correlation coefficient (R(p)). It has been found that PLSR model has good quality, r=0.9202, q=0.7956, and R(p)=0.6649 for M1 model based on the training set of 57 samples. To search the most important structural factors affecting the BBB permeability of compounds, we performed the values of the variable importance in projection (VIP) analysis for MEDV descriptors. It was found that some structural fragments in compounds, such as -CH(3), -CH(2)-, =CH-, =C, triple bond C-, -CH<, =C<, =N-, -NH-, =O, and -OH, are the most important factors affecting the BBB permeability. (c) 2010. Published by Elsevier Inc.

  10. Sensitivity of magnetic field-line pitch angle measurements to sawtooth events in tokamaks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ko, J., E-mail: jinseok@nfri.re.kr

    2016-11-15

    The sensitivity of the pitch angle profiles measured by the motional Stark effect (MSE) diagnostic to the evolution of the safety factor, q, profiles during the tokamak sawtooth events has been investigated for Korea Superconducting Tokamak Advanced Research (KSTAR). An analytic relation between the tokamak pitch angle, γ, and q estimates that Δγ ∼ 0.1° is required for detecting Δq ∼ 0.05 near the magnetic axis (not at the magnetic axis, though). The pitch angle becomes less sensitive to the same Δq for the middle and outer regions of the plasma (Δγ ∼ 0.5°). At the magnetic axis, it ismore » not straightforward to directly relate the γ sensitivity to Δq since the gradient of γ(R), where R is the major radius of the tokamak, is involved. Many of the MSE data obtained from the 2015 KSTAR campaign, when calibrated carefully, can meet these requirements with the time integration down to 10 ms. The analysis with the measured data shows that the pitch angle profiles and their gradients near the magnetic axis can resolve the change of the q profiles including the central safety factor, q{sub 0}, during the sawtooth events.« less

  11. Compact Si-based asymmetric MZI waveguide on SOI as a thermo-optical switch

    NASA Astrophysics Data System (ADS)

    Rizal, C. S.; Niraula, B.

    2018-03-01

    A compact low power consuming asymmetric MZI based optical modulator with fast response time has been proposed on SOI platform. The geometrical and performance characteristics were analyzed in depth and optimized using coupled mode analysis and FDTD simulation tools, respectively. It was tested with and without implementation of thermo-optic (TO) effect. The device showed good frequency modulating characteristics when tested without the implementation of the TO effect. The fabricated device showed quality factor, Q ≈ 10,000, and this value is comparable to the Q of the device simulated with 25% transmission loss, showing FSR of 0.195 nm, FWHM ≈ 0.16 nm, and ER of 13 dB. With TO effect, it showed temperature sensitivity of 0.01 nm/°C and FSR of 0.19 nm. With the heater length of 4.18 mm, the device required 0.26 mW per π shift power with a switching voltage of 0.309 V, response time of 10 μ, and figure-of-merit of 2.6 mW μs. All of these characteristics make this device highly attractive for use in integrated Si photonics network as optical switch and wavelength modulator.

  12. Determination of short chain chlorinated paraffins in water by stir bar sorptive extraction-thermal desorption-gas chromatography-triple quadrupole tandem mass spectrometry.

    PubMed

    Tölgyessy, P; Nagyová, S; Sládkovičová, M

    2017-04-21

    A simple, robust, sensitive and environment friendly method for the determination of short chain chlorinated paraffins (SCCPs) in water using stir bar sorptive extraction (SBSE) coupled to thermal desorption-gas chromatography-triple quadrupole tandem mass spectrometry (TD-GC-QqQ-MS/MS) was developed. SBSE was performed using 100mL of water sample, 20mL of methanol as a modifier, and a commercial sorptive stir bar (with 10mm×0.5mm PDMS layer) during extraction period of 16h. After extraction, the sorptive stir bar was thermally desorbed and online analysed by GC-MS/MS. Method performance was evaluated for MilliQ and surface water spiked samples. For both types of matrices, a linear dynamic range of 0.5-3.0μgL -1 with correlation coefficients >0.999 and relative standard deviations (RSDs) of the relative response factors (RRFs) <12% was established. The limits of quantification (LOQs) of 0.06 and 0.08μgL -1 , and the precision (repeatability) of 6.4 and 7.7% (RSDs) were achieved for MilliQ and surface water, respectively. The method also showed good robustness, recovery and accuracy. The obtained performance characteristics indicate that the method is suitable for screening and monitoring and compliance checking with environmental quality standards (EQS, set by the EU) for SCCPs in surface waters. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Development and Validation Study of the Internet Overuse Screening Questionnaire

    PubMed Central

    Lee, Han-Kyeong; Lee, Hae-Woo; Han, Joo Hyun; Park, Subin; Ju, Seok-Jin; Choi, Kwanwoo; Lee, Ji Hyeon; Jeon, Hong Jin

    2018-01-01

    Objective Concerns over behavioral and emotional problems caused by excessive internet usage have been developed. This study intended to develop and a standardize questionnaire that can efficiently identify at-risk internet users through their internet usage habits. Methods Participants (n=158) were recruited at six I-will-centers located in Seoul, South Korea. From the initial 36 questionnaire item pool, 28 preliminary items were selected through expert evaluation and panel discussions. The construct validity, internal consistency, and concurrent validity were examined. We also conducted Receiver Operating Curve (ROC) analysis to assess diagnostic ability of the Internet Overuse Screening-Questionnaire (IOS-Q). Results The exploratory factor analysis yielded a five factor structure. Four factors with 17 items remained after items that had unclear factor loading were removed. The Cronbach’s alpha for the IOS-Q total score was 0.91, and test-retest reliability was 0.72. The correlation between Young’s internet addiction scale and K-scale supported concurrent validity. ROC analysis showed that the IOS-Q has superior diagnostic ability with the Area Under the Curve of 0.87. At the cut-off point of 25.5, the sensitivity was 0.93 and specificity was 0.86. Conclusion Overall, this study supports the use of IOS-Q for internet addiction research and for screening high-risk individuals. PMID:29669406

  14. Individual and Interactive Effects of Socio-Ecological Factors on Dengue Fever at Fine Spatial Scale: A Geographical Detector-Based Analysis

    PubMed Central

    Li, Xing; Wang, Jin; Lin, Hualiang; Chen, Lingling; Wu, Zhifeng; Ma, Wenjun

    2017-01-01

    Background: Large spatial heterogeneity was observed in the dengue fever outbreak in Guangzhou in 2014, however, the underlying reasons remain unknown. We examined whether socio-ecological factors affected the spatial distribution and their interactive effects. Methods: Moran’s I was applied to first examine the spatial cluster of dengue fever in Guangzhou. Nine socio-ecological factors were chosen to represent the urbanization level, economy, accessibility, environment, and the weather of the 167 townships/streets in Guangzhou, and then the geographical detector was applied to analyze the individual and interactive effects of these factors on the dengue outbreak. Results: Four clusters of dengue fever were identified in Guangzhou in 2014, including one hot spot in the central area of Guangzhou and three cold spots in the suburban districts. For individual effects, the temperature (q = 0.33) was the dominant factor of dengue fever, followed by precipitation (q = 0.24), road density (q = 0.24), and water body area (q = 0.23). For the interactive effects, the combination of high precipitation, high temperature, and high road density might result in increased dengue fever incidence. Moreover, urban villages might be the dengue fever hot spots. Conclusions: Our study suggests that some socio-ecological factors might either separately or jointly influence the spatial distribution of dengue fever in Guangzhou. PMID:28714925

  15. Individual and Interactive Effects of Socio-Ecological Factors on Dengue Fever at Fine Spatial Scale: A Geographical Detector-Based Analysis.

    PubMed

    Cao, Zheng; Liu, Tao; Li, Xing; Wang, Jin; Lin, Hualiang; Chen, Lingling; Wu, Zhifeng; Ma, Wenjun

    2017-07-17

    Background : Large spatial heterogeneity was observed in the dengue fever outbreak in Guangzhou in 2014, however, the underlying reasons remain unknown. We examined whether socio-ecological factors affected the spatial distribution and their interactive effects. Methods : Moran's I was applied to first examine the spatial cluster of dengue fever in Guangzhou. Nine socio-ecological factors were chosen to represent the urbanization level, economy, accessibility, environment, and the weather of the 167 townships/streets in Guangzhou, and then the geographical detector was applied to analyze the individual and interactive effects of these factors on the dengue outbreak. Results : Four clusters of dengue fever were identified in Guangzhou in 2014, including one hot spot in the central area of Guangzhou and three cold spots in the suburban districts. For individual effects, the temperature ( q = 0.33) was the dominant factor of dengue fever, followed by precipitation ( q = 0.24), road density ( q = 0.24), and water body area ( q = 0.23). For the interactive effects, the combination of high precipitation, high temperature, and high road density might result in increased dengue fever incidence. Moreover, urban villages might be the dengue fever hot spots. Conclusions : Our study suggests that some socio-ecological factors might either separately or jointly influence the spatial distribution of dengue fever in Guangzhou.

  16. Probing kinematics and fate of the Universe with linearly time-varying deceleration parameter

    NASA Astrophysics Data System (ADS)

    Akarsu, Özgür; Dereli, Tekin; Kumar, Suresh; Xu, Lixin

    2014-02-01

    The parametrizations q = q 0+ q 1 z and q = q 0+ q 1(1 - a/ a 0) (Chevallier-Polarski-Linder parametrization) of the deceleration parameter, which are linear in cosmic redshift z and scale factor a , have been frequently utilized in the literature to study the kinematics of the Universe. In this paper, we follow a strategy that leads to these two well-known parametrizations of the deceleration parameter as well as an additional new parametrization, q = q 0+ q 1(1 - t/ t 0), which is linear in cosmic time t. We study the features of this linearly time-varying deceleration parameter in contrast with the other two linear parametrizations. We investigate in detail the kinematics of the Universe by confronting the three models with the latest observational data. We further study the dynamics of the Universe by considering the linearly time-varying deceleration parameter model in comparison with the standard ΛCDM model. We also discuss the future of the Universe in the context of the models under consideration.

  17. High-Resolution 2D Lg and Pg Attenuation Models in the Basin and Range Region with Implications for Frequency-Dependent Q

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pyle, Moira L.; Walter, William R.; Pasyanos, Michael E.

    Here, we develop high–resolution, laterally varying attenuation models for the regional crustal phases of Pg and Lg in the area surrounding the Basin and Range Province in the western United States. The models are part of the characterization effort for the Source Physics Experiment (SPE), a series of chemical explosions at the Nevada National Security Site designed to improve our understanding of explosion source phenomenology. To aid in SPE modeling efforts, we focus on improving our ability to accurately predict amplitudes in a set of narrow frequency bands ranging from 0.5 to 16.0 Hz. To explore constraints at higher frequenciesmore » where data become more sparse, we test the robustness of the empirically observed power–law relationship between quality factor Q and frequency (Q=Q 0f γ). Our methodology uses a staged approach to consider attenuation, physics–based source terms, site terms, and geometrical spreading contributions to amplitude measurements. Tomographic inversion results indicate that the frequency dependence is a reasonable assumption as attenuation varies laterally for this region through all frequency bands considered. Our 2D Pg and Lg attenuation models correlate with underlying physiographic provinces, with the highest Q located in the Sierra Nevada Mountains and the Colorado plateau. Compared to a best–fitting 1D model for the region, the 2D model provides an 81% variance reduction overall for Lg residuals and a 75% reduction for Pg. These detailed attenuation maps at high frequencies will facilitate further study of local and regional distance P/S amplitude discriminants that are typically used to distinguish between earthquakes and underground explosions.« less

  18. High-Resolution 2D Lg and Pg Attenuation Models in the Basin and Range Region with Implications for Frequency-Dependent Q

    DOE PAGES

    Pyle, Moira L.; Walter, William R.; Pasyanos, Michael E.

    2017-10-24

    Here, we develop high–resolution, laterally varying attenuation models for the regional crustal phases of Pg and Lg in the area surrounding the Basin and Range Province in the western United States. The models are part of the characterization effort for the Source Physics Experiment (SPE), a series of chemical explosions at the Nevada National Security Site designed to improve our understanding of explosion source phenomenology. To aid in SPE modeling efforts, we focus on improving our ability to accurately predict amplitudes in a set of narrow frequency bands ranging from 0.5 to 16.0 Hz. To explore constraints at higher frequenciesmore » where data become more sparse, we test the robustness of the empirically observed power–law relationship between quality factor Q and frequency (Q=Q 0f γ). Our methodology uses a staged approach to consider attenuation, physics–based source terms, site terms, and geometrical spreading contributions to amplitude measurements. Tomographic inversion results indicate that the frequency dependence is a reasonable assumption as attenuation varies laterally for this region through all frequency bands considered. Our 2D Pg and Lg attenuation models correlate with underlying physiographic provinces, with the highest Q located in the Sierra Nevada Mountains and the Colorado plateau. Compared to a best–fitting 1D model for the region, the 2D model provides an 81% variance reduction overall for Lg residuals and a 75% reduction for Pg. These detailed attenuation maps at high frequencies will facilitate further study of local and regional distance P/S amplitude discriminants that are typically used to distinguish between earthquakes and underground explosions.« less

  19. High‐Resolution 2D Lg and Pg Attenuation Models in the Basin and Range Region with Implications for Frequency‐Dependent Q

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pyle, Moira L.; Walter, William R.; Pasyanos, Michael E.

    2017-10-24

    Here, we develop high–resolution, laterally varying attenuation models for the regional crustal phases of Pg and Lg in the area surrounding the Basin and Range Province in the western United States. The models are part of the characterization effort for the Source Physics Experiment (SPE), a series of chemical explosions at the Nevada National Security Site designed to improve our understanding of explosion source phenomenology. To aid in SPE modeling efforts, we focus on improving our ability to accurately predict amplitudes in a set of narrow frequency bands ranging from 0.5 to 16.0 Hz. To explore constraints at higher frequenciesmore » where data become more sparse, we test the robustness of the empirically observed power–law relationship between quality factor Q and frequency (Q=Q 0f γ). Our methodology uses a staged approach to consider attenuation, physics–based source terms, site terms, and geometrical spreading contributions to amplitude measurements. Tomographic inversion results indicate that the frequency dependence is a reasonable assumption as attenuation varies laterally for this region through all frequency bands considered. Our 2D Pg and Lg attenuation models correlate with underlying physiographic provinces, with the highest Q located in the Sierra Nevada Mountains and the Colorado plateau. Compared to a best–fitting 1D model for the region, the 2D model provides an 81% variance reduction overall for Lg residuals and a 75% reduction for Pg. These detailed attenuation maps at high frequencies will facilitate further study of local and regional distance P/S amplitude discriminants that are typically used to distinguish between earthquakes and underground explosions.« less

  20. Determination of small-field correction factors for cylindrical ionization chambers using a semiempirical method

    NASA Astrophysics Data System (ADS)

    Park, Kwangwoo; Bak, Jino; Park, Sungho; Choi, Wonhoon; Park, Suk Won

    2016-02-01

    A semiempirical method based on the averaging effect of the sensitive volumes of different air-filled ionization chambers (ICs) was employed to approximate the correction factors for beam quality produced from the difference in the sizes of the reference field and small fields. We measured the output factors using several cylindrical ICs and calculated the correction factors using a mathematical method similar to deconvolution; in the method, we modeled the variable and inhomogeneous energy fluence function within the chamber cavity. The parameters of the modeled function and the correction factors were determined by solving a developed system of equations as well as on the basis of the measurement data and the geometry of the chambers. Further, Monte Carlo (MC) computations were performed using the Monaco® treatment planning system to validate the proposed method. The determined correction factors (k{{Q\\text{msr}},Q}{{f\\text{smf}}, {{f}\\text{ref}}} ) were comparable to the values derived from the MC computations performed using Monaco®. For example, for a 6 MV photon beam and a field size of 1  ×  1 cm2, k{{Q\\text{msr}},Q}{{f\\text{smf}}, {{f}\\text{ref}}} was calculated to be 1.125 for a PTW 31010 chamber and 1.022 for a PTW 31016 chamber. On the other hand, the k{{Q\\text{msr}},Q}{{f\\text{smf}}, {{f}\\text{ref}}} values determined from the MC computations were 1.121 and 1.031, respectively; the difference between the proposed method and the MC computation is less than 2%. In addition, we determined the k{{Q\\text{msr}},Q}{{f\\text{smf}}, {{f}\\text{ref}}} values for PTW 30013, PTW 31010, PTW 31016, IBA FC23-C, and IBA CC13 chambers as well. We devised a method for determining k{{Q\\text{msr}},Q}{{f\\text{smf}}, {{f}\\text{ref}}} from both the measurement of the output factors and model-based mathematical computation. The proposed method can be useful in case the MC simulation would not be applicable for the clinical settings.

  1. Factors affecting the relationship between quantitative polymerase chain reaction (qPCR) and culture-based enumeration of Enterococcus in environmental waters.

    PubMed

    Raith, M R; Ebentier, D L; Cao, Y; Griffith, J F; Weisberg, S B

    2014-03-01

    To determine the extent to which discrepancies between qPCR and culture-based results in beach water quality monitoring can be attributed to: (i) within-method variability, (ii) between-method difference within each method class (qPCR or culture) and (iii) between-class difference. We analysed 306 samples using two culture-based (EPA1600 and Enterolert) and two qPCR (Taqman and Scorpion) methods, each in duplicate. Both qPCR methods correlated with EPA1600, but regression analyses indicated approximately 0·8 log10 unit overestimation by qPCR compared to culture methods. Differences between methods within a class were less than half of this and were minimal for between-replicate within a method. Using the 104 Enterococcus per 100 ml management decision threshold, Taqman qPCR indicated the same decisions as EPA1600 for 87% of the samples, but indicated beach posting for unhealthful water when EPA1600 did not for 12% of the samples. After accounting for within-method and within-class variability, 8% of the samples exhibited true between-class discrepancy where both qPCR methods indicated beach posting while both culture methods did not. Measurement target difference (DNA vs growth) accounted for the majority of the qPCR-vs-culture discrepancy, but its influence on monitoring application is outweighed by frequent incorrect posting with culture methods due to incubation time delay. This is the first study to quantify the frequency with which culture-vs-qPCR discrepancies can be attributed to target difference - vs - method variability. © 2013 The Society for Applied Microbiology.

  2. Chaperones in Polyglutamine Aggregation: Beyond the Q-Stretch

    PubMed Central

    Kuiper, E. F. E.; de Mattos, Eduardo P.; Jardim, Laura B.; Kampinga, Harm H.; Bergink, Steven

    2017-01-01

    Expanded polyglutamine (polyQ) stretches in at least nine unrelated proteins lead to inherited neuronal dysfunction and degeneration. The expansion size in all diseases correlates with age at onset (AO) of disease and with polyQ protein aggregation, indicating that the expanded polyQ stretch is the main driving force for the disease onset. Interestingly, there is marked interpatient variability in expansion thresholds for a given disease. Between different polyQ diseases the repeat length vs. AO also indicates the existence of modulatory effects on aggregation of the upstream and downstream amino acid sequences flanking the Q expansion. This can be either due to intrinsic modulation of aggregation by the flanking regions, or due to differential interaction with other proteins, such as the components of the cellular protein quality control network. Indeed, several lines of evidence suggest that molecular chaperones have impact on the handling of different polyQ proteins. Here, we review factors differentially influencing polyQ aggregation: the Q-stretch itself, modulatory flanking sequences, interaction partners, cleavage of polyQ-containing proteins, and post-translational modifications, with a special focus on the role of molecular chaperones. By discussing typical examples of how these factors influence aggregation, we provide more insight on the variability of AO between different diseases as well as within the same polyQ disorder, on the molecular level. PMID:28386214

  3. Fabrication of Silica Ultra High Quality Factor Microresonators

    PubMed Central

    Maker, Ashley J.; Armani, Andrea M.

    2012-01-01

    Whispering gallery resonant cavities confine light in circular orbits at their periphery.1-2 The photon storage lifetime in the cavity, quantified by the quality factor (Q) of the cavity, can be in excess of 500ns for cavities with Q factors above 100 million. As a result of their low material losses, silica microcavities have demonstrated some of the longest photon lifetimes to date1-2. Since a portion of the circulating light extends outside the resonator, these devices can also be used to probe the surroundings. This interaction has enabled numerous experiments in biology, such as single molecule biodetection and antibody-antigen kinetics, as well as discoveries in other fields, such as development of ultra-low-threshold microlasers, characterization of thin films, and cavity quantum electrodynamics studies.3-7 The two primary silica resonant cavity geometries are the microsphere and the microtoroid. Both devices rely on a carbon dioxide laser reflow step to achieve their ultra-high-Q factors (Q>100 million).1-2,8-9 However, there are several notable differences between the two structures. Silica microspheres are free-standing, supported by a single optical fiber, whereas silica microtoroids can be fabricated on a silicon wafer in large arrays using a combination of lithography and etching steps. These differences influence which device is optimal for a given experiment. Here, we present detailed fabrication protocols for both types of resonant cavities. While the fabrication of microsphere resonant cavities is fairly straightforward, the fabrication of microtoroid resonant cavities requires additional specialized equipment and facilities (cleanroom). Therefore, this additional requirement may also influence which device is selected for a given experiment. Introduction An optical resonator efficiently confines light at specific wavelengths, known as the resonant wavelengths of the device. 1-2 The common figure of merit for these optical resonators is the quality factor or Q. This term describes the photon lifetime (τo) within the resonator, which is directly related to the resonator's optical losses. Therefore, an optical resonator with a high Q factor has low optical losses, long photon lifetimes, and very low photon decay rates (1/τo). As a result of the long photon lifetimes, it is possible to build-up extremely large circulating optical field intensities in these devices. This very unique property has allowed these devices to be used as laser sources and integrated biosensors.10 A unique sub-class of resonators is the whispering gallery mode optical microcavity. In these devices, the light is confined in circular orbits at the periphery. Therefore, the field is not completely confined within the device, but evanesces into the environment. Whispering gallery mode optical cavities have demonstrated some of the highest quality factors of any optical resonant cavity to date.9,11 Therefore, these devices are used throughout science and engineering, including in fundamental physics studies and in telecommunications as well as in biodetection experiments. 3-7,12 Optical microcavities can be fabricated from a wide range of materials and in a wide variety of geometries. A few examples include silica and silicon microtoroids, silicon, silicon nitride, and silica microdisks, micropillars, and silica and polymer microrings.13-17 The range in quality factor (Q) varies as dramatically as the geometry. Although both geometry and high Q are important considerations in any field, in many applications, there is far greater leverage in boosting device performance through Q enhancement. Among the numerous options detailed previously, the silica microsphere and the silica microtoroid resonator have achieved some of the highest Q factors to date.1,9 Additionally, as a result of the extremely low optical loss of silica from the visible through the near-IR, both microspheres and microtoroids are able to maintain their Q factors over a wide range of testing wavelengths.18 Finally, because silica is inherently biocompatible, it is routinely used in biodetection experiments. In addition to high material absorption, there are several other potential loss mechanisms, including surface roughness, radiation loss, and contamination loss.2 Through an optimization of the device size, it is possible to eliminate radiation losses, which arise from poor optical field confinement within the device. Similarly, by storing a device in an appropriately clean environment, contamination of the surface can be minimized. Therefore, in addition to material loss, surface scattering is the primary loss mechanism of concern.2,8 In silica devices, surface scattering is minimized by using a laser reflow technique, which melts the silica through surface tension induced reflow. While spherical optical resonators have been studied for many years, it is only with recent advances in fabrication technologies that researchers been able to fabricate high quality silica optical toroidal microresonators (Q>100 million) on a silicon substrate, thus paving the way for integration with microfluidics.1 The present series of protocols details how to fabricate both silica microsphere and microtoroid resonant cavities. While silica microsphere resonant cavities are well-established, microtoroid resonant cavities were only recently invented.1 As many of the fundamental methods used to fabricate the microsphere are also used in the more complex microtoroid fabrication procedure, by including both in a single protocol it will enable researchers to more easily trouble-shoot their experiments. PMID:22805153

  4. First French Pilot Quality Assessment of the EndoPredict Test for Early Luminal Breast Carcinoma.

    PubMed

    Lehmann-Che, Jacqueline; Miquel, Catherine; Wong, Jennifer; Callens, Celine; Rouleau, Etienne; Quillien, Veronique; Lozano, Nicolas; Cayre, Anne; Lacroix, Ludovic; Bieche, Ivan; Bertheau, Philippe; Teixeira, Luis; Llorca, Frederique Penault; Lamy, Pierre Jean; DE Cremoux, Patricia

    2018-05-01

    Genomic signatures are needed for the determination of prognosis in patients with early stage, estrogen receptor (ER)-positive, human epidermal growth factor receptor 2 (HER2)-negative breast cancers. EndoPredict test is a RNA-based multigene assay that assesses the risk of 10-year relapse in this context. Quality assessment is a mandatory requirement for a laboratory to address the analytical quality of these molecular analyses. The aim of the study was to demonstrate the robustness of this prognostic test, its usefulness for the patient's treatment strategy, at the national level. This study presents a pilot quality assessment (QA) of the EndoPredict test using composite design, including the follow-up of internal control values (qREF) of the 12 genes of the assay for 151 independent tests and one formalin-fixed paraffin embedded (FFPE) breast cancer sample. The evaluation of the test was performed by comparing the results of six independent medical laboratories. All measures were highly reproducible and quantification of the qREF showed a standard deviation of less than 0.50 and a coefficient of variation always of <2%. All laboratories found concordant results for the breast cancer samples. The mean EndoPredict (EP) score for the breast cancer sample was 4.97±0.24. The mean of EPclin score was 3.07±0.05. This first French independent reported QA assessed the robustness and reproducibility of the EndoPredict test. Such a simple composite design could represent an adapted QA for an expensive diagnostic test. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  5. An Analysis Method for Superconducting Resonator Parameter Extraction with Complex Baseline Removal

    NASA Technical Reports Server (NTRS)

    Cataldo, Giuseppe

    2014-01-01

    A new semi-empirical model is proposed for extracting the quality (Q) factors of arrays of superconducting microwave kinetic inductance detectors (MKIDs). The determination of the total internal and coupling Q factors enables the computation of the loss in the superconducting transmission lines. The method used allows the simultaneous analysis of multiple interacting discrete resonators with the presence of a complex spectral baseline arising from reflections in the system. The baseline removal allows an unbiased estimate of the device response as measured in a cryogenic instrumentation setting.

  6. Design and optical characterization of high-Q guided-resonance modes in the slot-graphite photonic crystal lattice.

    PubMed

    Martínez, Luis Javier; Huang, Ningfeng; Ma, Jing; Lin, Chenxi; Jaquay, Eric; Povinelli, Michelle L

    2013-12-16

    A new photonic crystal structure is generated by using a regular graphite lattice as the base and adding a slot in the center of each unit cell to enhance field confinement. The theoretical Q factor in an ideal structure is over 4 × 10(5). The structure was fabricated on a silicon-on-insulator wafer and optically characterized by transmission spectroscopy. The resonance wavelength and quality factor were measured as a function of slot height. The measured trends show good agreement with simulation.

  7. Monte Carlo calculations of electron beam quality conversion factors for several ion chamber types.

    PubMed

    Muir, B R; Rogers, D W O

    2014-11-01

    To provide a comprehensive investigation of electron beam reference dosimetry using Monte Carlo simulations of the response of 10 plane-parallel and 18 cylindrical ion chamber types. Specific emphasis is placed on the determination of the optimal shift of the chambers' effective point of measurement (EPOM) and beam quality conversion factors. The EGSnrc system is used for calculations of the absorbed dose to gas in ion chamber models and the absorbed dose to water as a function of depth in a water phantom on which cobalt-60 and several electron beam source models are incident. The optimal EPOM shifts of the ion chambers are determined by comparing calculations of R50 converted from I50 (calculated using ion chamber simulations in phantom) to R50 calculated using simulations of the absorbed dose to water vs depth in water. Beam quality conversion factors are determined as the calculated ratio of the absorbed dose to water to the absorbed dose to air in the ion chamber at the reference depth in a cobalt-60 beam to that in electron beams. For most plane-parallel chambers, the optimal EPOM shift is inside of the active cavity but different from the shift determined with water-equivalent scaling of the front window of the chamber. These optimal shifts for plane-parallel chambers also reduce the scatter of beam quality conversion factors, kQ, as a function of R50. The optimal shift of cylindrical chambers is found to be less than the 0.5 rcav recommended by current dosimetry protocols. In most cases, the values of the optimal shift are close to 0.3 rcav. Values of kecal are calculated and compared to those from the TG-51 protocol and differences are explained using accurate individual correction factors for a subset of ion chambers investigated. High-precision fits to beam quality conversion factors normalized to unity in a beam with R50 = 7.5 cm (kQ (')) are provided. These factors avoid the use of gradient correction factors as used in the TG-51 protocol although a chamber dependent optimal shift in the EPOM is required when using plane-parallel chambers while no shift is needed with cylindrical chambers. The sensitivity of these results to parameters used to model the ion chambers is discussed and the uncertainty related to the practical use of these results is evaluated. These results will prove useful as electron beam reference dosimetry protocols are being updated. The analysis of this work indicates that cylindrical ion chambers may be appropriate for use in low-energy electron beams but measurements are required to characterize their use in these beams.

  8. Up, down, and strange nucleon axial form factors from lattice QCD

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Green, Jeremy; Hasan, Nesreen; Meinel, Stefan

    Here, we report a calculation of the nucleon axial form factorsmore » $$G_A^q(Q^2)$$ and $$G_P^q(Q^2)$$ for all three light quark flavors $$q\\in\\{u,d,s\\}$$ in the range $$0\\leq Q^2\\lesssim 1.2\\text{ GeV}^2$$ using lattice QCD. Our work was done using a single ensemble with pion mass 317 MeV and made use of the hierarchical probing technique to efficiently evaluate the required disconnected loops. We perform nonperturbative renormalization of the axial current, including a nonperturbative treatment of the mixing between light and strange currents due to the singlet-nonsinglet difference caused by the axial anomaly. The form factor shapes are fit using the model-independent $z$ expansion. From $$G_A^q(Q^2)$$, we determine the quark contributions to the nucleon spin and axial radii. By extrapolating the isovector $$G_P^{u-d}(Q^2)$$, we obtain the induced pseudoscalar coupling relevant for ordinary muon capture and the pion-nucleon coupling constant. We also found that the disconnected contributions to $$G_P$$ form factors are large, and give an interpretation based on the dominant influence of the pseudoscalar poles in these form factors.« less

  9. Up, down, and strange nucleon axial form factors from lattice QCD

    DOE PAGES

    Green, Jeremy; Hasan, Nesreen; Meinel, Stefan; ...

    2017-06-14

    Here, we report a calculation of the nucleon axial form factorsmore » $$G_A^q(Q^2)$$ and $$G_P^q(Q^2)$$ for all three light quark flavors $$q\\in\\{u,d,s\\}$$ in the range $$0\\leq Q^2\\lesssim 1.2\\text{ GeV}^2$$ using lattice QCD. Our work was done using a single ensemble with pion mass 317 MeV and made use of the hierarchical probing technique to efficiently evaluate the required disconnected loops. We perform nonperturbative renormalization of the axial current, including a nonperturbative treatment of the mixing between light and strange currents due to the singlet-nonsinglet difference caused by the axial anomaly. The form factor shapes are fit using the model-independent $z$ expansion. From $$G_A^q(Q^2)$$, we determine the quark contributions to the nucleon spin and axial radii. By extrapolating the isovector $$G_P^{u-d}(Q^2)$$, we obtain the induced pseudoscalar coupling relevant for ordinary muon capture and the pion-nucleon coupling constant. We also found that the disconnected contributions to $$G_P$$ form factors are large, and give an interpretation based on the dominant influence of the pseudoscalar poles in these form factors.« less

  10. Acoustic properties of a crack containing magmatic or hydrothermal fluids

    USGS Publications Warehouse

    Kumagai, H.; Chouet, B.A.

    2000-01-01

    We estimate the acoustic properties of a crack containing maginatic or hydrothermal fluids to quantify the source properties of long-period (LP) events observed in volcanic areas assuming that a crack-like structure is the source of LP events. The tails of synthetic waveforms obtained from a model of a fluid-driven crack are analyzed by the Sompi method to determine the complex frequencies of one of the modes of crack resonance over a wide range of the model parameters ??/a and ??f/??s, where ?? is the P wave velocity of the rock matrix, a is the sound speed of the fluid, and ??f and ??s are the densities of the fluid and rock matrix, respectively. The quality factor due to radiation loss (Qr) for the selected mode almost monotonically increases with increasing ??/a, while the dimensionless frequency (??) of the mode decreases with increasing ??/a and ??f/??s. These results are used to estimate Q and ?? for a crack containing various types of fluids (gas-gas mixtures, liquid-gas mixtures, and dusty and misty gases) for values of a, ??f, and quality factor due to intrinsic losses (Qi) appropriate for these types of fluids, in which Q is given by Q-1 = Qr-1 + Qi-1. For a crack containing such fluids, we obtain Q ranging from almost unity to several hundred, which consistently explains the wide variety of quality factors measured in LP events observed at various volcanoes. We underscore the importance of dusty and misty gases containing small-size particles with radii around 1 ??m to explain long-lasting oscillations with Q significantly larger than 100. Our results may provide a basis for the interpretation of spatial and temporal variations in the observed complex frequencies of LP events in terms of fluid compositions beneath volcanoes. Copyright 2000 by the American Geophysical Union.

  11. TH-AB-201-09 [Medical Physics, Jun 2016, v. 43(6)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mirzakhanian, L; Benmakhlouf, H; Seuntjens, J

    2016-06-15

    Purpose: To determine the k-(Q-msr,Q)^(f-msr,f-ref ) factor, introduced in the small field formalism for five common type chambers used in the calibration of Leksell Gamma-Knife Perfexion model over a range of different phantom electron densities. Methods: Five chamber types including Exradin-A16, A14SL, A14, A1SL and IBA-CC04 are modeled in EGSnrc and PENELOPE Monte Carlo codes using the blueprints provided by the manufacturers. The chambers are placed in a previously proposed water-filled phantom and four 16-cm diameter spherical phantoms made of liquid water, Solid Water, ABS and polystyrene. Dose to the cavity of the chambers and a small water volume aremore » calculated using EGSnrc/PENELOPE codes. The calculations are performed over a range of phantom electron densities for two chamber orientations. Using the calculated dose-ratio in reference and machine specific reference field, the k-(Q-msr,Q)^(f-msr,f-ref ) factor can be determined. Results: When chambers are placed along the symmetry axis of the collimator block (z-axis), the CC04 requires the smallest correction followed by A1SL and A16. However, when detectors are placed perpendicular to z-axis, A14SL needs the smallest and A16 the largest correction. Moreover, an increase in the phantom electron density results in a linear increase in the k-(Q-msr,Q)^(f-msr,f-ref ). Depending on the chambers, the agreement between this study and a previous study performed varies between 0.05–0.70% for liquid water, 0.07–0.85% for Solid Water and 0.00–0.60% for ABS phantoms. After applying the EGSnrc-calculated k-(Q-msr,Q)^(f-msr,f-ref ) factors for A16 to the previously measured dose-rates in liquid water, Solid Water and ABS normalized to the dose-rate measured with TG-21 protocol and ABS phantom, the dose-rate ratios are found to be 1.004±0.002, 0.996±0.002 and 0.998±0.002 (3σ) respectively. Conclusion: Knowing the electron density of the phantoms, the calculated k-(Q-msr,Q)^(f-msr,f-ref ) values in this work will enable users to apply the appropriate correction for their own specific phantom material. LM acknowledges partial support by the CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council (Grant number: 432290)« less

  12. Field-driven quantum phase transitions in S =1/2 spin chains

    NASA Astrophysics Data System (ADS)

    Iaizzi, Adam; Damle, Kedar; Sandvik, Anders W.

    2017-05-01

    We study the magnetization process of a one-dimensional extended Heisenberg model, the J -Q model, as a function of an external magnetic field h . In this model, J represents the traditional antiferromagnetic Heisenberg exchange and Q is the strength of a competing four-spin interaction. Without external field, this system hosts a twofold-degenerate dimerized (valence-bond solid) state above a critical value qc≈0.85 where q ≡Q /J . The dimer order is destroyed and replaced by a partially polarized translationally invariant state at a critical field value. We find magnetization jumps (metamagnetism) between the partially polarized and fully polarized state for q >qmin , where we have calculated qmin=2/9 exactly. For q >qmin , two magnons (flipped spins on a fully polarized background) attract and form a bound state. Quantum Monte Carlo studies confirm that the bound state corresponds to the first step of an instability leading to a finite magnetization jump for q >qmin . Our results show that neither geometric frustration nor spin anisotropy are necessary conditions for metamagnetism. Working in the two-magnon subspace, we also find evidence pointing to the existence of metamagnetism in the unfrustrated J1-J2 chain (J1>0 ,J2<0 ), but only if J2 is spin anisotropic. In addition to the studies at zero temperature, we also investigate quantum-critical scaling near the transition into the fully polarized state for q ≤qmin at T >0 . While the expected "zero-scale-factor" universality is clearly seen for q =0 and q ≪qmin , for q closer to qmin we find that extremely low temperatures are required to observe the asymptotic behavior, due to the influence of the tricritical point at qmin. In the low-energy theory, one can expect the quartic nonlinearity to vanish at qmin and a marginal sixth-order term should govern the scaling, which leads to a crossover at a temperature T*(q ) between logarithmic tricritical scaling and zero-scale-factor universality, with T*(q ) →0 when q →qmin .

  13. Left Handed Materials Based on Magnetic Nanocomposites

    DTIC Science & Technology

    2006-10-18

    theory that unifies DNMs and SNMs as a function of two flmdamental material parameters: quality factors for permittivity (Qe=e’/e") and permeability (Qu...simultaneously negative effective permeability/uff and permittivity Seff to form LHM or only single negative parameter (SNM) to form negative indexed...developed a theory that unifies DNMs and SNMs as a function of two fundamental material parameters: quality factors for permittivity (Q, = -’/ 6") and

  14. Divergence of the long-wavelength collective diffusion coefficient in quasi-one- and quasi-two-dimensional colloidal suspensions.

    PubMed

    Lin, Binhua; Cui, Bianxiao; Xu, Xinliang; Zangi, Ronen; Diamant, Haim; Rice, Stuart A

    2014-02-01

    We report the results of experimental studies of the short-time-long-wavelength behavior of collective particle displacements in quasi-one-dimensional (q1D) and quasi-two-dimensional (q2D) colloid suspensions. Our results are reported via the q → 0 behavior of the hydrodynamic function H(q) that relates the effective collective diffusion coefficient D(e)(q), with the static structure factor S(q) and the self-diffusion coefficient of isolated particles D(0): H(q) ≡ D(e)(q)S(q)/D(0). We find an apparent divergence of H(q) as q → 0 with the form H(q) ∝ q(-γ) (1.7 < γ < 1.9) for both q1D and q2D colloid suspensions. Given that S(q) does not diverge as q → 0 we infer that D(e)(q) does. This behavior is qualitatively different from that of the three-dimensional H(q) and D(e)(q) as q → 0, and the divergence is of a different functional form from that predicted for the diffusion coefficient in one-component one-dimensional and two-dimensional fluids not subject to boundary conditions that define the dimensionality of the system. We provide support for the contention that the boundary conditions that define a confined system play a very important role in determining the long-wavelength behavior of the collective diffusion coefficient from two sources: (i) the results of simulations of H(q) and D(e)(q) in quasi-1D and quasi-2D systems and (ii) verification, using data from the work of Lin, Rice and Weitz [Phys. Rev. E 51, 423 (1995)], of the prediction by Bleibel et al., arXiv:1305.3715, that D(e)(q) for a monolayer of colloid particles constrained to lie in the interface between two fluids diverges as q(-1) as q → 0.

  15. Comparison of Integrated Radiation Transport Models with TEPC Measurements for the Average Quality Factors in Spaceflights

    NASA Technical Reports Server (NTRS)

    Kim, Myung-Hee Y.; Nikjoo, Hooshang; Dicello, John F.; Pisacane, Vincent; Cucinotta, Francis A.

    2007-01-01

    The purpose of this work is to test our theoretical model for the interpretation of radiation data measured in space. During the space missions astronauts are exposed to the complex field of radiation type and kinetic energies from galactic cosmic rays (GCR), trapped protons, and sometimes solar particle events (SPEs). The tissue equivalent proportional counter (TEPC) is a simple time-dependent approach for radiation monitoring for astronauts on board the International Space Station. Another and a newer approach to Microdosimetry is the use of silicon-on-insulator (SOI) technology launched on the MidSTAR-1 mission in low Earth orbit (LEO). In the radiation protection practice, the average quality factor of a radiation field is defined as a function of linear energy transfer (LET), Q(sub ave)(LET). However, TEPC measures the average quality factor as a function of the lineal energy y, Q(sub ave)(y), defined as the average energy deposition in a volume divided by the average chord length of the volume. Lineal energy, y, deviates from LET due to energy straggling, delta-ray escape or entry, and nuclear fragments produced in the detector volume. Monte Carlo track structure simulation was employed to obtain the response of a TEPC irradiated with charged particle for an equivalent site diameter of 1 micron of wall-less counter. The calculated data of the energy absorption in the wall-less counter were compiled for various y values for several ion types at various discrete projectile energy levels. For the simulation of TEPC response from the mixed radiation environments inside a spacecraft, such as, Space Shuttle and International Space Station, the complete microdosimetric TEPC response, f( y, E, Z), were calculated with the Monte Carlo theoretical results by using the first order Lagrangian interpolation for a monovariate function at a given y value (y = 0.1 keV/micron 5000 keV/micron) at any projectile energy level (E = 0.01 MeV/u to 50,000 MeV/u) of each specific radiation type (Z = 1 to 28). Because the anomalous response has been observed at large event sizes in the experiment due to the escape of energy out of sensitive volume by delta-rays and the entry of delta-rays from the high-density wall into the low-density gas-volume cavity, Monte Carlo simulation was also made for the response of a walled-TEPC with wall thickness 2 mm and density 1 g/cm(exp 3). The radius of cavity was set to 6.35 mm and a gas density 7.874 x 10(exp -5) g/cm(exp 3). The response of the walled- and the wall-less counters were compared. The average quality factor Q(sub ave)(y) for trapped protons on STS-89 demonstrated the good agreement between the model calculations and flight TEPC data as shown. Using an integrated space radiation model (this includes the transport codes HZETRN and BRYNTRN, the quantum nuclear interaction model QMSFRG) and the resultant response distribution functions of walled-TEPC from Monte-Carlo track simulations, we compared model calculations with walled-TEPC measurements from NASA missions in LEO and made predictions for the lunar and the Mars missions. The Q(sub ave)(y) values for the trapped or the solar protons ranged from 1.9-2.5. This over-estimates the Qave(LET) values which ranged from 1.4-1.6. Both quantities increase with shield thickness due to nuclear fragmentation. The Q(sub ave)(LET) for the complete GCR spectra was found to be 3.5-4.5, while flight TEPCs measured 2.9-3.4 for Q(sub ave)(y). The GCR values are decreasing with the shield thickness. Our analysis for a proper interpretation of data supports the use of TEPCs for monitoring space radiation environment.

  16. Measurements of the electric form factor of the neutron up to Q2=3.4 GeV2 using the reaction 3He(e,e'n)pp.

    PubMed

    Riordan, S; Abrahamyan, S; Craver, B; Kelleher, A; Kolarkar, A; Miller, J; Cates, G D; Liyanage, N; Wojtsekhowski, B; Acha, A; Allada, K; Anderson, B; Aniol, K A; Annand, J R M; Arrington, J; Averett, T; Beck, A; Bellis, M; Boeglin, W; Breuer, H; Calarco, J R; Camsonne, A; Chen, J P; Chudakov, E; Coman, L; Crowe, B; Cusanno, F; Day, D; Degtyarenko, P; Dolph, P A M; Dutta, C; Ferdi, C; Fernández-Ramírez, C; Feuerbach, R; Fraile, L M; Franklin, G; Frullani, S; Fuchs, S; Garibaldi, F; Gevorgyan, N; Gilman, R; Glamazdin, A; Gomez, J; Grimm, K; Hansen, J-O; Herraiz, J L; Higinbotham, D W; Holmes, R; Holmstrom, T; Howell, D; de Jager, C W; Jiang, X; Jones, M K; Katich, J; Kaufman, L J; Khandaker, M; Kelly, J J; Kiselev, D; Korsch, W; LeRose, J; Lindgren, R; Markowitz, P; Margaziotis, D J; Beck, S May-Tal; Mayilyan, S; McCormick, K; Meziani, Z-E; Michaels, R; Moffit, B; Nanda, S; Nelyubin, V; Ngo, T; Nikolenko, D M; Norum, B; Pentchev, L; Perdrisat, C F; Piasetzky, E; Pomatsalyuk, R; Protopopescu, D; Puckett, A J R; Punjabi, V A; Qian, X; Qiang, Y; Quinn, B; Rachek, I; Ransome, R D; Reimer, P E; Reitz, B; Roche, J; Ron, G; Rondon, O; Rosner, G; Saha, A; Sargsian, M M; Sawatzky, B; Segal, J; Shabestari, M; Shahinyan, A; Shestakov, Yu; Singh, J; Sirca, S; Souder, P; Stepanyan, S; Stibunov, V; Sulkosky, V; Tajima, S; Tobias, W A; Udias, J M; Urciuoli, G M; Vlahovic, B; Voskanyan, H; Wang, K; Wesselmann, F R; Vignote, J R; Wood, S A; Wright, J; Yao, H; Zhu, X

    2010-12-31

    The electric form factor of the neutron was determined from studies of the reaction 3He(e,e'n)pp in quasielastic kinematics in Hall A at Jefferson Lab. Longitudinally polarized electrons were scattered off a polarized target in which the nuclear polarization was oriented perpendicular to the momentum transfer. The scattered electrons were detected in a magnetic spectrometer in coincidence with neutrons that were registered in a large-solid-angle detector. More than doubling the Q2 range over which it is known, we find G(E)(n)=0.0236±0.0017(stat)±0.0026(syst), 0.0208±0.0024±0.0019, and 0.0147±0.0020±0.0014 for Q(2)=1.72, 2.48, and 3.41 GeV2, respectively.

  17. Measurements of the Electric Form Factor of the Neutron up to Q2 = 3.4 GeV2 using the Reaction He-3(e,e'n)pp

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riordan, Seamus; Craver, Brandon; Kelleher, Aidan

    The electric form factor of the neutron was determined from studies of the reaction \\rea{} in quasi-elastic kinematics in Hall A at Jefferson Lab. Longitudinally polarized electrons were scattered off a polarized target in which the nuclear polarization was oriented perpendicular to the momentum transfer. The scattered electrons were detected in a magnetic spectrometer in coincidence with neutrons that were registered in a large-solid-angle detector. More than doubling themore » $Q^2$$-range over which it is known, we find \\GEn{}$$ = 0.0225 \\pm 0.0017 (stat) \\pm 0.0024 (syst)$, $$0.0200 \\pm 0.0023 \\pm 0.0018$$, and $$0.0142 \\pm 0.0019 \\pm 0.0013$$ for $Q^2$ = 1.72, 2.48, and 3.41~\\gevsq, respectively.« less

  18. Do stressed mothers have heavier children? A meta-analysis on the relationship between maternal stress and child body mass index.

    PubMed

    Tate, E B; Wood, W; Liao, Y; Dunton, G F

    2015-05-01

    Child obesity continues to be a prevalent public health issue. This meta-analysis synthesized 17 studies investigating the association between levels of psychological stress experienced by mothers and the body mass index of their children. The overall standardized mean difference effect size was positive and significantly different from zero in cross-sectional d = 0.20 (k = 14, 95% confidence interval [CI]: 0.06, 0.34) and longitudinal studies d = 0.18 (k = 5, 95% CI: 0.00, 0.351) and had significant heterogeneity in both (cross-sectional, Q[13] = 193.00, P < 0.001; longitudinal, Q[4] = 29.46, P < 0.001). In longitudinal studies, effect sizes were larger when children also would have experienced the stressor, Q(6) = 4.68, P < 0.05, for toddlers than infants, Q(4) = 5.04, P < 0.05, and in higher quality studies, Q(4) = 14.58, P < 0.05. Results highlight the potential benefits of including a parent stress management component in childhood obesity prevention programmes. © 2015 World Obesity.

  19. High quality-factor fano metasurface comprising a single resonator unit cell

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sinclair, Michael B.; Warne, Larry K.; Basilio, Lorena I.

    A new monolithic resonator metasurface design achieves ultra-high Q-factors while using only one resonator per unit cell. The metasurface relies on breaking the symmetry of otherwise highly symmetric resonators to induce intra-resonator mixing of bright and dark modes (rather than inter-resonator couplings), and is scalable from the near-infrared to radio frequencies and can be easily implemented in dielectric materials. The resulting high-quality-factor Fano metasurface can be used in many sensing, spectral filtering, and modulation applications.

  20. Experimental evidences for molecular origin of low-Q peak in neutron/x-ray scattering of 1-alkyl-3-methylimidazolium bis(trifluoromethanesulfonyl)amide ionic liquids

    NASA Astrophysics Data System (ADS)

    Fujii, Kenta; Kanzaki, Ryo; Takamuku, Toshiyuki; Kameda, Yasuo; Kohara, Shinji; Kanakubo, Mitsuhiro; Shibayama, Mitsuhiro; Ishiguro, Shin-ichi; Umebayashi, Yasuhiro

    2011-12-01

    Short- and long-range liquid structures of [CnmIm+][TFSA-] with n = 2, 4, 6, 8, 10, and 12 have been studied by high-energy x-ray diffraction (HEXRD) and small-angle neutron scattering (SANS) experiments with the aid of MD simulations. Observed x-ray structure factor, S(Q), for the ionic liquids with the alkyl-chain length n > 6 exhibited a characteristic peak in the low-Q range of 0.2-0.4 Å -1, indicating the heterogeneity of their ionic liquids. SANS profiles IH(Q) and ID(Q) for the normal and the alkyl group deuterated ionic liquids, respectively, showed significant peaks for n = 10 and 12 without no form factor component for large spherical or spheroidal aggregates like micelles in solution. The peaks for n = 10 and 12 evidently disappeared in the difference SANS profiles ΔI(Q) [=ID(Q) - IH(Q)], although that for n = 12 slightly remained. This suggests that the long-range correlations originated from the alkyl groups hardly contribute to the low-Q peak intensity in SANS. To reveal molecular origin of the low-Q peak, we introduce here a new function; x-ray structure factor intensity at a given Q as a function of r, SQpeak(r). The SQpeak(r) function suggests that the observed low-Q peak intensity depending on n is originated from liquid structures at two r-region of 5-8 and 8-15 Å for all ionic liquids examined except for n = 12. Atomistic MD simulations are consistent with the HEXRD and SANS experiments, and then we discussed the relationship between both variations of low-Q peak and real-space structure with lengthening the alkyl group of the CnmIm.

  1. Attention in western Nevada: Preliminary results from earthquake and explosion sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hough, S.E.; Anderson, J.G.; Patton, H.J.

    1989-02-01

    We present preliminary results from a study of the attenuation of regional seismic waves at frequencies between 1 and 15 Hz and distances up to 250 km in Western Nevada. Following the methods of Anderson and Hough (1984) and Hough et al. (1988), we parameterize the asymptote of the high frequency acceleration spectrum by the two-parameter model. We relate the model parameters to a two-layer model for Q/sub i/ and Q/sub d/, the freuqency-independent and the frequency dependent components of the quality factor. We compare our results to previously published Q studies in the Basin and Range and find thatmore » our estimate of total Q, Q/sub t/, in the shallow crust is consistent with shear wave Q at close distances with previous estimates of coda Q (Singh and Hermann, 1983) and LgQ (Chavez and Priestley, 1986), suggesting that both coda Q and LgQ are insensitive to near-surface contributions to attenuation.« less

  2. Light-meson masses in an unquenched quark model

    DOE PAGES

    Chen, Xiaoyun; Ping, Jialun; Roberts, Craig D.; ...

    2018-05-17

    We perform a coupled-channels calculation of the masses of light mesons with the quantum numbers IJ P=-, (I,J) = 0,1, by includingmore » $$q\\bar{q}$$ and ($$q\\bar{q}$$) 2 components in a nonrelativistic chiral quark model. The coupling between two- and four-quark configurations is realized through a 3P 0 quark-pair creation model. With the usual form of this operator, the mass shifts are large and negative, an outcome which raises serious issues of validity for the quenched quark model. Therefore, we introduce some improvements of the 3P 0 operator in order to reduce the size of the mass shifts. By introducing two simple factors, physically well motivated, the coupling between $$q\\bar{q}$$ and ($$q\\bar{q}$$) 2 components is weakened, producing mass shifts that are around 10%–20% of hadron bare masses.« less

  3. Light-meson masses in an unquenched quark model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Xiaoyun; Ping, Jialun; Roberts, Craig D.

    We perform a coupled-channels calculation of the masses of light mesons with the quantum numbers IJ P=-, (I,J) = 0,1, by includingmore » $$q\\bar{q}$$ and ($$q\\bar{q}$$) 2 components in a nonrelativistic chiral quark model. The coupling between two- and four-quark configurations is realized through a 3P 0 quark-pair creation model. With the usual form of this operator, the mass shifts are large and negative, an outcome which raises serious issues of validity for the quenched quark model. Therefore, we introduce some improvements of the 3P 0 operator in order to reduce the size of the mass shifts. By introducing two simple factors, physically well motivated, the coupling between $$q\\bar{q}$$ and ($$q\\bar{q}$$) 2 components is weakened, producing mass shifts that are around 10%–20% of hadron bare masses.« less

  4. The effect of Q factor on gross mechanical efficiency and muscular activation in cycling.

    PubMed

    Disley, B X; Li, F-X

    2014-02-01

    Unexplored in scientific literature, Q Factor describes the horizontal width between bicycle pedals and determines where the foot is laterally positioned throughout the pedal stroke. The aim of the study was to determine whether changing Q Factor has a beneficial effect upon cycling efficiency and muscular activation. A total of 24 trained cyclists (11 men, 13 women; VO2max 57.5 ml·kg/min ± 6.1) pedaled at 60% of peak power output for 5 min at 90 rpm using Q Factors of 90, 120, 150, and 180 mm. Power output and gas were collected and muscular activity of the gastrocnemius medialis (GM), tibialis anterior (TA), vastus medialis (VM), and vastus lateralis (VL) measured using surface electromyography. There was a significant increase (P < 0.006) in gross mechanical efficiency (GME) for 90 and 120 mm (both 19.38%) compared with 150 and 180 mm (19.09% and 19.05%), representing an increase in external mechanical work performed of approximately 4-5 W (1.5-2.0%) at submaximal power outputs. There was no significant difference in the level of activity or timing of activation of the GM, TA, VM, and VL between Q Factors. Other muscles used in cycling, and possibly an improved application of force during the pedal stroke may play a role in the observed increase in GME with narrower Q Factors. © 2012 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Identifying key components for an effective case report poster: an observational study.

    PubMed

    Willett, Lisa L; Paranjape, Anuradha; Estrada, Carlos

    2009-03-01

    Residents demonstrate scholarly activity by presenting posters at academic meetings. Although recommendations from national organizations are available, evidence identifying which components are most important is not. To develop and test an evaluation tool to measure the quality of case report posters and identify the specific components most in need of improvement. Faculty evaluators reviewed case report posters and provided on-site feedback to presenters at poster sessions of four annual academic general internal medicine meetings. A newly developed ten-item evaluation form measured poster quality for specific components of content, discussion, and format (5-point Likert scale, 1 = lowest, 5 = highest). Evaluation tool performance, including Cronbach alpha and inter-rater reliability, overall poster scores, differences across meetings and evaluators and specific components of the posters most in need of improvement. Forty-five evaluators from 20 medical institutions reviewed 347 posters. Cronbach's alpha of the evaluation form was 0.84 and inter-rater reliability, Spearman's rho 0.49 (p < 0.001). The median score was 4.1 (Q1 -Q3, 3.7-4.6)(Q1 = 25th, Q3 = 75th percentile). The national meeting median score was higher than the regional meetings (4.4 vs, 4.0, P < 0.001). We found no difference in faculty scores. The following areas were identified as most needing improvement: clearly state learning objectives, tie conclusions to learning objectives, and use appropriate amount of words. Our evaluation tool provides empirical data to guide trainees as they prepare posters for presentation which may improve poster quality and enhance their scholarly productivity.

  6. Measurement of Form-Factor-Independent Observables in the Decay B0→K*0μ+μ-

    NASA Astrophysics Data System (ADS)

    Aaij, R.; Adeva, B.; Adinolfi, M.; Adrover, C.; Affolder, A.; Ajaltouni, Z.; Albrecht, J.; Alessio, F.; Alexander, M.; Ali, S.; Alkhazov, G.; Alvarez Cartelle, P.; Alves, A. A., Jr.; Amato, S.; Amerio, S.; Amhis, Y.; Anderlini, L.; Anderson, J.; Andreassen, R.; Andrews, J. E.; Appleby, R. B.; Aquines Gutierrez, O.; Archilli, F.; Artamonov, A.; Artuso, M.; Aslanides, E.; Auriemma, G.; Baalouch, M.; Bachmann, S.; Back, J. J.; Baesso, C.; Balagura, V.; Baldini, W.; Barlow, R. J.; Barschel, C.; Barsuk, S.; Barter, W.; Bauer, Th.; Bay, A.; Beddow, J.; Bedeschi, F.; Bediaga, I.; Belogurov, S.; Belous, K.; Belyaev, I.; Ben-Haim, E.; Bencivenni, G.; Benson, S.; Benton, J.; Berezhnoy, A.; Bernet, R.; Bettler, M.-O.; van Beuzekom, M.; Bien, A.; Bifani, S.; Bird, T.; Bizzeti, A.; Bjørnstad, P. M.; Blake, T.; Blanc, F.; Blouw, J.; Blusk, S.; Bocci, V.; Bondar, A.; Bondar, N.; Bonivento, W.; Borghi, S.; Borgia, A.; Bowcock, T. J. V.; Bowen, E.; Bozzi, C.; Brambach, T.; van den Brand, J.; Bressieux, J.; Brett, D.; Britsch, M.; Britton, T.; Brook, N. H.; Brown, H.; Burducea, I.; Bursche, A.; Busetto, G.; Buytaert, J.; Cadeddu, S.; Callot, O.; Calvi, M.; Calvo Gomez, M.; Camboni, A.; Campana, P.; Campora Perez, D.; Carbone, A.; Carboni, G.; Cardinale, R.; Cardini, A.; Carranza-Mejia, H.; Carson, L.; Carvalho Akiba, K.; Casse, G.; Castillo Garcia, L.; Cattaneo, M.; Cauet, Ch.; Cenci, R.; Charles, M.; Charpentier, Ph.; Chen, P.; Chiapolini, N.; Chrzaszcz, M.; Ciba, K.; Cid Vidal, X.; Ciezarek, G.; Clarke, P. E. L.; Clemencic, M.; Cliff, H. V.; Closier, J.; Coca, C.; Coco, V.; Cogan, J.; Cogneras, E.; Collins, P.; Comerma-Montells, A.; Contu, A.; Cook, A.; Coombes, M.; Coquereau, S.; Corti, G.; Couturier, B.; Cowan, G. A.; Craik, D. C.; Cunliffe, S.; Currie, R.; D'Ambrosio, C.; David, P.; David, P. N. Y.; Davis, A.; De Bonis, I.; De Bruyn, K.; De Capua, S.; De Cian, M.; De Miranda, J. M.; De Paula, L.; De Silva, W.; De Simone, P.; Decamp, D.; Deckenhoff, M.; Del Buono, L.; Déléage, N.; Derkach, D.; Deschamps, O.; Dettori, F.; Di Canto, A.; Dijkstra, H.; Dogaru, M.; Donleavy, S.; Dordei, F.; Dosil Suárez, A.; Dossett, D.; Dovbnya, A.; Dupertuis, F.; Durante, P.; Dzhelyadin, R.; Dziurda, A.; Dzyuba, A.; Easo, S.; Egede, U.; Egorychev, V.; Eidelman, S.; van Eijk, D.; Eisenhardt, S.; Eitschberger, U.; Ekelhof, R.; Eklund, L.; El Rifai, I.; Elsasser, Ch.; Falabella, A.; Färber, C.; Fardell, G.; Farinelli, C.; Farry, S.; Ferguson, D.; Fernandez Albor, V.; Ferreira Rodrigues, F.; Ferro-Luzzi, M.; Filippov, S.; Fiore, M.; Fitzpatrick, C.; Fontana, M.; Fontanelli, F.; Forty, R.; Francisco, O.; Frank, M.; Frei, C.; Frosini, M.; Furcas, S.; Furfaro, E.; Gallas Torreira, A.; Galli, D.; Gandelman, M.; Gandini, P.; Gao, Y.; Garofoli, J.; Garosi, P.; Garra Tico, J.; Garrido, L.; Gaspar, C.; Gauld, R.; Gersabeck, E.; Gersabeck, M.; Gershon, T.; Ghez, Ph.; Gibson, V.; Giubega, L.; Gligorov, V. V.; Göbel, C.; Golubkov, D.; Golutvin, A.; Gomes, A.; Gorbounov, P.; Gordon, H.; Gotti, C.; Grabalosa Gándara, M.; Graciani Diaz, R.; Granado Cardoso, L. A.; Graugés, E.; Graziani, G.; Grecu, A.; Greening, E.; Gregson, S.; Griffith, P.; Grünberg, O.; Gui, B.; Gushchin, E.; Guz, Yu.; Gys, T.; Hadjivasiliou, C.; Haefeli, G.; Haen, C.; Haines, S. C.; Hall, S.; Hamilton, B.; Hampson, T.; Hansmann-Menzemer, S.; Harnew, N.; Harnew, S. T.; Harrison, J.; Hartmann, T.; He, J.; Head, T.; Heijne, V.; Hennessy, K.; Henrard, P.; Hernando Morata, J. A.; van Herwijnen, E.; Hess, M.; Hicheur, A.; Hicks, E.; Hill, D.; Hoballah, M.; Hombach, C.; Hopchev, P.; Hulsbergen, W.; Hunt, P.; Huse, T.; Hussain, N.; Hutchcroft, D.; Hynds, D.; Iakovenko, V.; Idzik, M.; Ilten, P.; Jacobsson, R.; Jaeger, A.; Jans, E.; Jaton, P.; Jawahery, A.; Jing, F.; John, M.; Johnson, D.; Jones, C. R.; Joram, C.; Jost, B.; Kaballo, M.; Kandybei, S.; Kanso, W.; Karacson, M.; Karbach, T. M.; Kenyon, I. R.; Ketel, T.; Keune, A.; Khanji, B.; Kochebina, O.; Komarov, I.; Koopman, R. F.; Koppenburg, P.; Korolev, M.; Kozlinskiy, A.; Kravchuk, L.; Kreplin, K.; Kreps, M.; Krocker, G.; Krokovny, P.; Kruse, F.; Kucharczyk, M.; Kudryavtsev, V.; Kurek, K.; Kvaratskheliya, T.; La Thi, V. N.; Lacarrere, D.; Lafferty, G.; Lai, A.; Lambert, D.; Lambert, R. W.; Lanciotti, E.; Lanfranchi, G.; Langenbruch, C.; Latham, T.; Lazzeroni, C.; Le Gac, R.; van Leerdam, J.; Lees, J.-P.; Lefèvre, R.; Leflat, A.; Lefrançois, J.; Leo, S.; Leroy, O.; Lesiak, T.; Leverington, B.; Li, Y.; Li Gioi, L.; Liles, M.; Lindner, R.; Linn, C.; Liu, B.; Liu, G.; Lohn, S.; Longstaff, I.; Lopes, J. H.; Lopez-March, N.; Lu, H.; Lucchesi, D.; Luisier, J.; Luo, H.; Machefert, F.; Machikhiliyan, I. V.; Maciuc, F.; Maev, O.; Malde, S.; Manca, G.; Mancinelli, G.; Maratas, J.; Marconi, U.; Marino, P.; Märki, R.; Marks, J.; Martellotti, G.; Martens, A.; Martín Sánchez, A.; Martinelli, M.; Martinez Santos, D.; Martins Tostes, D.; Martynov, A.; Massafferri, A.; Matev, R.; Mathe, Z.; Matteuzzi, C.; Maurice, E.; Mazurov, A.; McCarthy, J.; McNab, A.; McNulty, R.; McSkelly, B.; Meadows, B.; Meier, F.; Meissner, M.; Merk, M.; Milanes, D. A.; Minard, M.-N.; Molina Rodriguez, J.; Monteil, S.; Moran, D.; Morawski, P.; Mordà, A.; Morello, M. J.; Mountain, R.; Mous, I.; Muheim, F.; Müller, K.; Muresan, R.; Muryn, B.; Muster, B.; Naik, P.; Nakada, T.; Nandakumar, R.; Nasteva, I.; Needham, M.; Neubert, S.; Neufeld, N.; Nguyen, A. D.; Nguyen, T. D.; Nguyen-Mau, C.; Nicol, M.; Niess, V.; Niet, R.; Nikitin, N.; Nikodem, T.; Nomerotski, A.; Novoselov, A.; Oblakowska-Mucha, A.; Obraztsov, V.; Oggero, S.; Ogilvy, S.; Okhrimenko, O.; Oldeman, R.; Orlandea, M.; Otalora Goicochea, J. M.; Owen, P.; Oyanguren, A.; Pal, B. K.; Palano, A.; Palczewski, T.; Palutan, M.; Panman, J.; Papanestis, A.; Pappagallo, M.; Parkes, C.; Parkinson, C. J.; Passaleva, G.; Patel, G. D.; Patel, M.; Patrick, G. N.; Patrignani, C.; Pavel-Nicorescu, C.; Pazos Alvarez, A.; Pellegrino, A.; Penso, G.; Pepe Altarelli, M.; Perazzini, S.; Perez Trigo, E.; Pérez-Calero Yzquierdo, A.; Perret, P.; Perrin-Terrin, M.; Pescatore, L.; Pesen, E.; Petridis, K.; Petrolini, A.; Phan, A.; Picatoste Olloqui, E.; Pietrzyk, B.; Pilař, T.; Pinci, D.; Playfer, S.; Plo Casasus, M.; Polci, F.; Polok, G.; Poluektov, A.; Polycarpo, E.; Popov, A.; Popov, D.; Popovici, B.; Potterat, C.; Powell, A.; Prisciandaro, J.; Pritchard, A.; Prouve, C.; Pugatch, V.; Puig Navarro, A.; Punzi, G.; Qian, W.; Rademacker, J. H.; Rakotomiaramanana, B.; Rangel, M. S.; Raniuk, I.; Rauschmayr, N.; Raven, G.; Redford, S.; Reid, M. M.; dos Reis, A. C.; Ricciardi, S.; Richards, A.; Rinnert, K.; Rives Molina, V.; Roa Romero, D. A.; Robbe, P.; Roberts, D. A.; Rodrigues, E.; Rodriguez Perez, P.; Roiser, S.; Romanovsky, V.; Romero Vidal, A.; Rouvinet, J.; Ruf, T.; Ruffini, F.; Ruiz, H.; Ruiz Valls, P.; Sabatino, G.; Saborido Silva, J. J.; Sagidova, N.; Sail, P.; Saitta, B.; Salustino Guimaraes, V.; Sanmartin Sedes, B.; Sannino, M.; Santacesaria, R.; Santamarina Rios, C.; Santovetti, E.; Sapunov, M.; Sarti, A.; Satriano, C.; Satta, A.; Savrie, M.; Savrina, D.; Schaack, P.; Schiller, M.; Schindler, H.; Schlupp, M.; Schmelling, M.; Schmidt, B.; Schneider, O.; Schopper, A.; Schune, M.-H.; Schwemmer, R.; Sciascia, B.; Sciubba, A.; Seco, M.; Semennikov, A.; Senderowska, K.; Sepp, I.; Serra, N.; Serrano, J.; Seyfert, P.; Shapkin, M.; Shapoval, I.; Shatalov, P.; Shcheglov, Y.; Shears, T.; Shekhtman, L.; Shevchenko, O.; Shevchenko, V.; Shires, A.; Silva Coutinho, R.; Sirendi, M.; Skwarnicki, T.; Smith, N. A.; Smith, E.; Smith, J.; Smith, M.; Sokoloff, M. D.; Soler, F. J. P.; Soomro, F.; Souza, D.; Souza De Paula, B.; Spaan, B.; Sparkes, A.; Spradlin, P.; Stagni, F.; Stahl, S.; Steinkamp, O.; Stevenson, S.; Stoica, S.; Stone, S.; Storaci, B.; Straticiuc, M.; Straumann, U.; Subbiah, V. K.; Sun, L.; Swientek, S.; Syropoulos, V.; Szczekowski, M.; Szczypka, P.; Szumlak, T.; T'Jampens, S.; Teklishyn, M.; Teodorescu, E.; Teubert, F.; Thomas, C.; Thomas, E.; van Tilburg, J.; Tisserand, V.; Tobin, M.; Tolk, S.; Tonelli, D.; Topp-Joergensen, S.; Torr, N.; Tournefier, E.; Tourneur, S.; Tran, M. T.; Tresch, M.; Tsaregorodtsev, A.; Tsopelas, P.; Tuning, N.; Ubeda Garcia, M.; Ukleja, A.; Urner, D.; Ustyuzhanin, A.; Uwer, U.; Vagnoni, V.; Valenti, G.; Vallier, A.; Van Dijk, M.; Vazquez Gomez, R.; Vazquez Regueiro, P.; Vázquez Sierra, C.; Vecchi, S.; Velthuis, J. J.; Veltri, M.; Veneziano, G.; Vesterinen, M.; Viaud, B.; Vieira, D.; Vilasis-Cardona, X.; Vollhardt, A.; Volyanskyy, D.; Voong, D.; Vorobyev, A.; Vorobyev, V.; Voß, C.; Voss, H.; Waldi, R.; Wallace, C.; Wallace, R.; Wandernoth, S.; Wang, J.; Ward, D. R.; Watson, N. K.; Webber, A. D.; Websdale, D.; Whitehead, M.; Wicht, J.; Wiechczynski, J.; Wiedner, D.; Wiggers, L.; Wilkinson, G.; Williams, M. P.; Williams, M.; Wilson, F. F.; Wimberley, J.; Wishahi, J.; Wislicki, W.; Witek, M.; Wotton, S. A.; Wright, S.; Wu, S.; Wyllie, K.; Xie, Y.; Xing, Z.; Yang, Z.; Young, R.; Yuan, X.; Yushchenko, O.; Zangoli, M.; Zavertyaev, M.; Zhang, F.; Zhang, L.; Zhang, W. C.; Zhang, Y.; Zhelezov, A.; Zhokhov, A.; Zhong, L.; Zvyagin, A.

    2013-11-01

    We present a measurement of form-factor-independent angular observables in the decay B0→K*(892)0μ+μ-. The analysis is based on a data sample corresponding to an integrated luminosity of 1.0fb-1, collected by the LHCb experiment in pp collisions at a center-of-mass energy of 7 TeV. Four observables are measured in six bins of the dimuon invariant mass squared q2 in the range 0.1

  7. Quality correction factors of composite IMRT beam deliveries: Theoretical considerations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bouchard, Hugo

    2012-11-15

    Purpose: In the scope of intensity modulated radiation therapy (IMRT) dosimetry using ionization chambers, quality correction factors of plan-class-specific reference (PCSR) fields are theoretically investigated. The symmetry of the problem is studied to provide recommendable criteria for composite beam deliveries where correction factors are minimal and also to establish a theoretical limit for PCSR delivery k{sub Q} factors. Methods: The concept of virtual symmetric collapsed (VSC) beam, being associated to a given modulated composite delivery, is defined in the scope of this investigation. Under symmetrical measurement conditions, any composite delivery has the property of having a k{sub Q} factor identicalmore » to its associated VSC beam. Using this concept of VSC, a fundamental property of IMRT k{sub Q} factors is demonstrated in the form of a theorem. The sensitivity to the conditions required by the theorem is thoroughly examined. Results: The theorem states that if a composite modulated beam delivery produces a uniform dose distribution in a volume V{sub cyl} which is symmetric with the cylindrical delivery and all beams fulfills two conditions in V{sub cyl}: (1) the dose modulation function is unchanged along the beam axis, and (2) the dose gradient in the beam direction is constant for a given lateral position; then its associated VSC beam produces no lateral dose gradient in V{sub cyl}, no matter what beam modulation or gantry angles are being used. The examination of the conditions required by the theorem lead to the following results. The effect of the depth-dose gradient not being perfectly constant with depth on the VSC beam lateral dose gradient is found negligible. The effect of the dose modulation function being degraded with depth on the VSC beam lateral dose gradient is found to be only related to scatter and beam hardening, as the theorem holds also for diverging beams. Conclusions: The use of the symmetry of the problem in the present paper leads to a valuable theorem showing that k{sub Q} factors of composite IMRT beam deliveries are close to unity under specific conditions. The theoretical limit k{sub Q{sub p{sub c{sub s{sub r,Q{sub m{sub s{sub r}{sup f{sub p}{sub c}{sub s}{sub r},f{sub m}{sub s}{sub r}}}}}}}}}=1 is determined based on the property of PCSR deliveries to provide a uniform dose in the target volume. The present approach explains recent experimental observations and proposes ideal conditions for IMRT reference dosimetry. The result of this study could potentially serve as a theoretical basis for reference dosimetry of composite IMRT beam deliveries or for routine IMRT quality assurance.« less

  8. Dutch Translation and Psychometric Testing of the 9-Item Shared Decision Making Questionnaire (SDM-Q-9) and Shared Decision Making Questionnaire-Physician Version (SDM-Q-Doc) in Primary and Secondary Care

    PubMed Central

    Rodenburg-Vandenbussche, Sumayah; Pieterse, Arwen H.; Kroonenberg, Pieter M.; Scholl, Isabelle; van der Weijden, Trudy; Luyten, Gre P. M.; Kruitwagen, Roy F. P. M.; den Ouden, Henk; Carlier, Ingrid V. E.; van Vliet, Irene M.; Zitman, Frans G.; Stiggelbout, Anne M.

    2015-01-01

    Purpose The SDM-Q-9 and SDM-Q-Doc measure patient and physician perception of the extent of shared decision making (SDM) during a physician-patient consultation. So far, no self-report instrument for SDM was available in Dutch, and validation of the scales in other languages has been limited. The aim of this study was to translate both scales into Dutch and assess their psychometric characteristics. Methods Participants were patients and their treating physicians (general practitioners and medical specialists). Patients (N = 182) rated their consultation using the SDM-Q-9, 43 physicians rated their consultations using the SDM-Q-Doc (N = 201). Acceptability, reliability (internal consistency), and the factorial structure of the instruments were determined. For convergent validity the CPSpost was used. Results Reliabilities of both scales were high (alpha SDM-Q-9 0.88; SDM-Q-Doc 0.87). The SDM-Q-9 and SDM-Q-Doc total scores correlated as expected with the CPSpost (SDM-Q-9: r = 0.29; SDM-Q-Doc: r = 0.48) and were significantly different between the CPSpost categories, with lowest mean scores when the physician made the decision alone. Principal Component Analyses showed a two-component model for each scale. A confirmatory factor analysis yielded a mediocre, but acceptable, one-factor model, if Item 1 was excluded; for both scales the best indices of fit were obtained for a one-factor solution, if both Items 1 and 9 were excluded. Conclusion The Dutch SDM-Q-9 and SDM-Q-Doc demonstrate good acceptance and reliability; they correlated as expected with the CPSpost and are suitable for use in Dutch primary and specialised care. Although the best model fit was found when excluding Items 1 and 9, we believe these items address important aspects of SDM. Therefore, also based on the coherence with theory and comparability with other studies, we suggest keeping all nine items of the scale. Further research on the SDM-concept in patients and physicians, in different clinical settings and different countries, is necessary to gain a better understanding of the SDM-construct and its measurement. PMID:26151946

  9. Heavy-to-light scalar form factors from Muskhelishvili-Omnès dispersion relations

    NASA Astrophysics Data System (ADS)

    Yao, D.-L.; Fernandez-Soler, P.; Albaladejo, M.; Guo, F.-K.; Nieves, J.

    2018-04-01

    By solving the Muskhelishvili-Omnès integral equations, the scalar form factors of the semileptonic heavy meson decays D→ π \\bar{ℓ }ν _ℓ , D→ {\\bar{K}} \\bar{ℓ }ν _ℓ , {\\bar{B}}→ π ℓ \\bar{ν }_ℓ and {\\bar{B}}_s→ K ℓ \\bar{ν }_ℓ are simultaneously studied. As input, we employ unitarized heavy meson-Goldstone boson chiral coupled-channel amplitudes for the energy regions not far from thresholds, while, at high energies, adequate asymptotic conditions are imposed. The scalar form factors are expressed in terms of Omnès matrices multiplied by vector polynomials, which contain some undetermined dispersive subtraction constants. We make use of heavy quark and chiral symmetries to constrain these constants, which are fitted to lattice QCD results both in the charm and the bottom sectors, and in this latter sector to the light-cone sum rule predictions close to q^2=0 as well. We find a good simultaneous description of the scalar form factors for the four semileptonic decay reactions. From this combined fit, and taking advantage that scalar and vector form factors are equal at q^2=0, we obtain |V_{cd}|=0.244± 0.022, |V_{cs}|=0.945± 0.041 and |V_{ub}|=(4.3± 0.7)× 10^{-3} for the involved Cabibbo-Kobayashi-Maskawa (CKM) matrix elements. In addition, we predict the following vector form factors at q^2=0: |f_+^{D→ η }(0)|=0.01± 0.05, |f_+^{D_s→ K}(0)|=0.50 ± 0.08, |f_+^{D_s→ η }(0)|=0.73± 0.03 and |f_+^{{\\bar{B}}→ η }(0)|=0.82 ± 0.08, which might serve as alternatives to determine the CKM elements when experimental measurements of the corresponding differential decay rates become available. Finally, we predict the different form factors above the q^2-regions accessible in the semileptonic decays, up to moderate energies amenable to be described using the unitarized coupled-channel chiral approach.

  10. Study of \\Bpilnu and \\Brholnu decays and determination of \\Vub at \\babar

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wulsin, H.Wells

    2011-02-07

    The authors report a measurement of the branching fractions for B{sup 0} {yields} {pi}{sup -}{ell}{sup +}{nu} and B{sup 0} {yields} {rho}{sup -}{ell}{sup +}{nu} decays using charged and neutral B decays with isospin constraints. They find {beta}(B{sup 0} {yields} {pi}{sup -}{ell}{sup +}{nu}) = (1.41 {+-} 0.05 {+-} 0.07) x 10{sup -4}, and {beta}(B{sup 0} {yields} {rho}{sup -}{ell}{sup +}{nu}) = (1.75 {+-} 0.15 {+-} 0.27) x 10{sup -4}, where the first error is statistical and the second is systematic. They measure {Delta}{beta}/{Delta}q{sup 2}, with 6 q{sup 2} bins for B{sup 0} {yields} {pi}{sup -}{ell}{sup +}{nu} and 3 q{sup 2} bins for B{supmore » 0} {yields} {rho}{sup -}{ell}{sup +}{nu}, and compare the distributions in data with theoretical predictions for the form factors. They use these branching fractions and form-factor calculations to determine |V{sub ub}|. Based on a combined fit to the FNAL/MILC lattice QCD calculation and data over the full q{sup 2} range, they find |V{sub ub}| = (2.95 {+-} 0.31) x 10{sup -3}.« less

  11. Calculations of the first frequency moment of the structure factor in the BCS model

    NASA Astrophysics Data System (ADS)

    Rendell, J. M.; Carbotte, J. P.

    1998-03-01

    We have calculated the first frequency moment of the dynamical structure factor, S(q,ω), known as the f-sum, using the BCS model of susceptibility, \\chi(q,ω), with phenomenological models of the normal state dispersion, tilde\\varepsilon_k, and the superconducting energy gap, Δ_k(T). We have found an explicit expression for the f-sum in both the normal state and the superconducting state. Numerically, we show that the f-sum is insensitive to temperature changes in the range 0 to the order of magnitude of T_c, to the state (normal or superconducting) and to the size and type of energy gap, Δ_k(T), in the superconducting state. The f-sum does depend intimately on the normal state dispersion model, tilde\\varepsilonk and on the filling in the first Brillouin zone. In addition, we show numerically that the f-sum is nearly constant for the Random Phase Approximation (RPA) of the susceptibility up to pseudo-potentials, U <= U_c, the critical potential. Thus, a large increase in Im \\chi(q_0,ω_0) at frequency ω0 and a potential U > 0 (e.g. examining the 41 meV peak at q0 = (π,π)), is compensated by commensurate reduction in Im \\chi(q_0,ω) at other frequencies.

  12. Biotic Interactions and Sunlight Affect Persistence of Fecal Indicator Bacteria and Microbial Source Tracking Genetic Markers in the Upper Mississippi River

    PubMed Central

    McMinn, Brian R.; Shanks, Orin C.; Sivaganesan, Mano; Fout, G. Shay; Ashbolt, Nicholas J.

    2014-01-01

    The sanitary quality of recreational waters that may be impacted by sewage is assessed by enumerating fecal indicator bacteria (FIB) (Escherichia coli and enterococci); these organisms are found in the gastrointestinal tracts of humans and many other animals, and hence their presence provides no information about the pollution source. Microbial source tracking (MST) methods can discriminate between different pollution sources, providing critical information to water quality managers, but relatively little is known about factors influencing the decay of FIB and MST genetic markers following release into aquatic environments. An in situ mesocosm was deployed at a temperate recreational beach in the Mississippi River to evaluate the effects of ambient sunlight and biotic interactions (predation, competition, and viral lysis) on the decay of culture-based FIB, as well as molecularly based FIB (Entero1a and GenBac3) and human-associated MST genetic markers (HF183 and HumM2) measured by quantitative real-time PCR (qPCR). In general, culturable FIB decayed the fastest, while molecularly based FIB and human-associated genetic markers decayed more slowly. There was a strong correlation between the decay of molecularly based FIB and that of human-associated genetic markers (r2, 0.96 to 0.98; P < 0.0001) but not between culturable FIB and any qPCR measurement. Overall, exposure to ambient sunlight may be an important factor in the early-stage decay dynamics but generally was not after continued exposure (i.e., after 120 h), when biotic interactions tended to be the only/major influential determinant of persistence. PMID:24747902

  13. Monte Carlo and experimental determination of correction factors for gamma knife perfexion small field dosimetry measurements

    NASA Astrophysics Data System (ADS)

    Zoros, E.; Moutsatsos, A.; Pappas, E. P.; Georgiou, E.; Kollias, G.; Karaiskos, P.; Pantelis, E.

    2017-09-01

    Detector-, field size- and machine-specific correction factors are required for precise dosimetry measurements in small and non-standard photon fields. In this work, Monte Carlo (MC) simulation techniques were used to calculate the k{{Qmsr},{{Q}0}}{{fmsr},{{f}ref}} and k{{Qclin},{{Q}msr}}{{fclin},{{f}msr}} correction factors for a series of ionization chambers, a synthetic microDiamond and diode dosimeters, used for reference and/or output factor (OF) measurements in the Gamma Knife Perfexion photon fields. Calculations were performed for the solid water (SW) and ABS plastic phantoms, as well as for a water phantom of the same geometry. MC calculations for the k{{Qclin},{{Q}msr}}{{fclin},{{f}msr}} correction factors in SW were compared against corresponding experimental results for a subset of ionization chambers and diode detectors. Reference experimental OF data were obtained through the weighted average of corresponding measurements using TLDs, EBT-2 films and alanine pellets. k{{Qmsr},{{Q}0}}{{fmsr},{{f}ref}} values close to unity (within 1%) were calculated for most of ionization chambers in water. Greater corrections of up to 6.0% were observed for chambers with relatively large air-cavity dimensions and steel central electrode. A phantom correction of 1.006 and 1.024 (breaking down to 1.014 from the ABS sphere and 1.010 from the accompanying ABS phantom adapter) were calculated for the SW and ABS phantoms, respectively, adding up to k{{Qmsr},{{Q}0}}{{fmsr},{{f}ref}} corrections in water. Both measurements and MC calculations for the diode and microDiamond detectors resulted in lower than unit k{{Qclin},{{Q}msr}}{{fclin},{{f}msr}} correction factors, due to their denser sensitive volume and encapsulation materials. In comparison, higher than unit k{{Qclin},{{Q}msr}}{{fclin},{{f}msr}} results for the ionization chambers suggested field size depended dose underestimations (being significant for the 4 mm field), with magnitude depending on the combination of contradicting phenomena associated with volume averaging and electron fluence perturbations. Finally, the presence of 0.5 mm air-gap between the diodes’ frontal surface and their phantom-inserts may considerably influence OF measurements, reaching 4.6% for the Razor diode.

  14. Retrospective Examination of Q Fever Endocarditis: An Underdiagnosed Disease in the Mainland of China

    PubMed Central

    Han, Xiao; Hsu, Jeffrey; Miao, Qi; Zhou, Bao-Tong; Fan, Hong-Wei; Xiong, Xiao-Lu; Wen, Bo-Hai; Wu, Lian; Yan, Xiao-Wei; Fang, Quan; Chen, Wei

    2017-01-01

    Background: Q fever endocarditis, a chronic illness caused by Coxiella burnetii, can be fatal if misdiagnosed or left untreated. Despite a relatively high positive rate of Q fever serology in healthy individuals in the mainland of China, very few cases of Q fever endocarditis have been reported. This study summarized cases of Q fever endocarditis among blood culture negative endocarditis (BCNE) patients and discussed factors attributing to the low diagnostic rate. Methods: We identified confirmed cases of Q fever endocarditis among 637 consecutive patients with infective endocarditis (IE) in the Peking Union Medical College Hospital between 2006 and 2016. The clinical findings for each confirmed case were recorded. BCNE patients were also examined and each BCNE patient's Q fever risk factors were identified. The risk factors and presence of Q fever serologic testing between BCNE patients suspected and unsuspected of Q fever were compared using the Chi-squared or Chi-squared with Yates’ correction for continuity. Results: Among the IE patients examined, there were 147 BCNE patients, of whom only 11 patients (7.5%) were suspected of Q fever and undergone serological testing for C. burnetii. Six out of 11 suspected cases were diagnosed as Q fever endocarditis. For the remaining136 BCNE patients, none of them was suspected of Q fever nor underwent relevant testing. Risk factors for Q fever endocarditis were comparable between suspected and unsuspected patients, with the most common risk factors being valvulopathy in both groups. However, significantly more patients had consulted the Infectious Diseases Division and undergone comprehensive diagnostic tests in the suspected group than the unsuspected group (100% vs. 63%, P = 0.03). Conclusions: Q fever endocarditis is a serious yet treatable condition. Lacking awareness of the disease may prevent BCNE patients from being identified, despite having Q fever risk factors. Increasing awareness and guideline adherence are crucial in avoiding misdiagnosing and missed diagnosing of the disease. PMID:28051025

  15. Effective bichromatic potential for ultra-high Q-factor photonic crystal slab cavities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alpeggiani, Filippo, E-mail: filippo.alpeggiani01@ateneopv.it; Andreani, Lucio Claudio; Gerace, Dario

    2015-12-28

    We introduce a confinement mechanism in photonic crystal slab cavities, which relies on the superposition of two incommensurate one-dimensional lattices in a line-defect waveguide. It is shown that the resulting photonic profile realizes an effective quasi-periodic bichromatic potential for the electromagnetic field confinement yielding extremely high quality (Q) factor nanocavities, while simultaneously keeping the mode volume close to the diffraction limit. We apply these concepts to pillar- and hole-based photonic crystal slab cavities, respectively, and a Q-factor improvement by over an order of magnitude is shown over existing designs, especially in pillar-based structures. Thanks to the generality and easy adaptationmore » of such confinement mechanism to a broad class of cavity designs and photonic lattices, this work opens interesting routes for applications where enhanced light–matter interaction in photonic crystal structures is required.« less

  16. Demonstration of a switchable damping system to allow low-noise operation of high-Q low-mass suspension systems

    NASA Astrophysics Data System (ADS)

    Hennig, Jan-Simon; Barr, Bryan W.; Bell, Angus S.; Cunningham, William; Danilishin, Stefan L.; Dupej, Peter; Gräf, Christian; Hough, James; Huttner, Sabina H.; Jones, Russell; Leavey, Sean S.; Pascucci, Daniela; Sinclair, Martin; Sorazu, Borja; Spencer, Andrew; Steinlechner, Sebastian; Strain, Kenneth A.; Wright, Jennifer; Zhang, Teng; Hild, Stefan

    2017-12-01

    Low-mass suspension systems with high-Q pendulum stages are used to enable quantum radiation pressure noise limited experiments. Utilizing multiple pendulum stages with vertical blade springs and materials with high-quality factors provides attenuation of seismic and thermal noise; however, damping of these high-Q pendulum systems in multiple degrees of freedom is essential for practical implementation. Viscous damping such as eddy-current damping can be employed, but it introduces displacement noise from force noise due to thermal fluctuations in the damping system. In this paper we demonstrate a passive damping system with adjustable damping strength as a solution for this problem that can be used for low-mass suspension systems without adding additional displacement noise in science mode. We show a reduction of the damping factor by a factor of 8 on a test suspension and provide a general optimization for this system.

  17. Use of the 9-item Shared Decision Making Questionnaire (SDM-Q-9 and SDM-Q-Doc) in intervention studies-A systematic review.

    PubMed

    Doherr, Hanna; Christalle, Eva; Kriston, Levente; Härter, Martin; Scholl, Isabelle

    2017-01-01

    The Shared Decision Making Questionnaire (SDM-Q-9 and SDM-Q-Doc) is a 9-item measure of the decisional process in medical encounters from both patients' and physicians' perspectives. It has good acceptance, feasibility, and reliability. This systematic review aimed to 1) evaluate the use of the SDM-Q-9 and SDM-Q-Doc in intervention studies on shared decision making (SDM) in clinical settings, 2) describe how the SDM-Q-9 and SDM-Q-Doc performed regarding sensitivity to change, and 3) assess the methodological quality of studies and study protocols that use the measure. We conducted a systematic review of studies published between 2010 and October 2015 that evaluated interventions to facilitate SDM. The search strategy comprised three databases (EMBASE, PsycINFO, and Medline), reference tracking, citation tracking, and personal knowledge. Two independent reviewers screened titles and abstracts as well as full texts of potentially relevant records. We extracted the data using a pilot tested sheet, and we assessed the methodological quality of included studies using the Quality Assessment Tools from the U.S. National Institute of Health (NIH). Five completed studies and six study protocols fulfilled the inclusion criteria. The measure was used in a variety of health care settings, mainly in Europe, to evaluate several types of interventions. The reported mean sum scores ranged from 42 to 75 on a scale from 0 to 100. In four studies no significant change was detected in the mean-differences between main groups. In the fifth study the difference was small. Quality assessment revealed a high risk of bias in four of the five completed studies, while the study protocols received moderate quality ratings. We found a wide range of areas in which the SDM-Q-9 and SDM-Q-Doc were applied. In the future this review may help researchers decide whether the measure fits their purposes. Furthermore, the review revealed risk of bias in previous trials that used the measure, and may help future trials decrease this risk. More research on the measure's sensitivity to change is strongly suggested.

  18. Strong tidal dissipation in Io and Jupiter from astrometric observations.

    PubMed

    Lainey, Valéry; Arlot, Jean-Eudes; Karatekin, Ozgür; Van Hoolst, Tim

    2009-06-18

    Io is the volcanically most active body in the Solar System and has a large surface heat flux. The geological activity is thought to be the result of tides raised by Jupiter, but it is not known whether the current tidal heat production is sufficiently high to generate the observed surface heat flow. Io's tidal heat comes from the orbital energy of the Io-Jupiter system (resulting in orbital acceleration), whereas dissipation of energy in Jupiter causes Io's orbital motion to decelerate. Here we report a determination of the tidal dissipation in Io and Jupiter through its effect on the orbital motions of the Galilean moons. Our results show that the rate of internal energy dissipation in Io (k(2)/Q = 0.015 +/- 0.003, where k(2) is the Love number and Q is the quality factor) is in good agreement with the observed surface heat flow, and suggest that Io is close to thermal equilibrium. Dissipation in Jupiter (k(2)/Q = (1.102 +/- 0.203) x 10(-5)) is close to the upper bound of its average value expected from the long-term evolution of the system, and dissipation in extrasolar planets may be higher than presently assumed. The measured secular accelerations indicate that Io is evolving inwards, towards Jupiter, and that the three innermost Galilean moons (Io, Europa and Ganymede) are evolving out of the exact Laplace resonance.

  19. Central Safety Factor and Normalized Beta Control Under Near-Zero Input Torque Constraints in DIII-D

    NASA Astrophysics Data System (ADS)

    Pajares, Andres; Wehner, William; Schuster, Eugenio; Burrell, Keith; Ferron, John; Walker, Michael; Humphreys, David; Lehigh University Team; Atomics Team, General

    2017-10-01

    DIII-D experiments have assessed the capability of combined central safety factor (q0) and normalized beta (βN) control under near-zero net torque to facilitate access to QH-mode with reverse Ip and normal Bt. Regulation of q0 and βN can prevent magneto-hydrodynamic instabilities that deteriorate plasma performance in discharges with a monotonically increasing safety-factor profile. Zero-input-torque scenarios are of special interest because future burning plasma tokamaks such as ITER will most likely operate with very low input torque, which makes these scenarios more susceptible to locked modes. To support studies of such scenarios, a controller for simultaneous regulation of q0 and βN has been developed using near-zero net input torque actuators including balanced neutral beam injection (NBI) and electron-cyclotron heating & current drive (ECH/ECCD). Experimental results show that in spite of the presence of locked modes the use of feedback control resulted in good tracking of the commanded q0 and βN when both ECCD/ECH and NBI were available. Supported by the US DOE under DE-SC0010661 and DE-FC02-04ER54698.

  20. Trends and risk factors for human Q fever in Australia, 1991-2014.

    PubMed

    Sloan-Gardner, T S; Massey, P D; Hutchinson, P; Knope, K; Fearnley, E

    2017-03-01

    Australian abattoir workers, farmers, veterinarians and people handling animal birthing products or slaughtering animals continue to be at high risk of Q fever despite an effective vaccine being available. National Notifiable Diseases Surveillance System data were analysed for the period 1991-2014, along with enhanced risk factor data from notified cases in the states of New South Wales and Queensland, to examine changes in the epidemiology of Q fever in Australia. The national Q fever notification rate reduced by 20% [incident rate ratio (IRR) 0·82] following the end of the National Q fever Management Program in 2006, and has increased since 2009 (IRR 1·01-1·34). Highest rates were in males aged 40-59 years (5·9/100 000) and 87% of Q fever cases occurred in New South Wales and Queensland. The age of Q fever cases and proportion of females increased over the study period. Based on the enhanced risk factor data, the most frequently listed occupation for Q fever cases involved contact with livestock, followed by 'no known risk' occupations. More complete and comparable enhanced risk factor data, at the State/Territory and national levels, would aid in further understanding of the epidemiology of Q fever.

  1. Modulation of nuclear factor-κB signaling and reduction of neural tube defects by quercetin-3-glucoside in embryos of diabetic mice.

    PubMed

    Tan, Chengyu; Meng, Fantong; Reece, E Albert; Zhao, Zhiyong

    2018-05-04

    Diabetes mellitus in early pregnancy increases the risk of birth defects in infants. Maternal hyperglycemia stimulates the expression of nitric oxide (NO) synthase 2 (NOS2), which can be regulated by transcription factors of the nuclear factor-κB (NF-κB) family. Increases in reactive nitrogen species (RNS) generate intracellular stress conditions, including nitrosative, oxidative, and endoplasmic reticulum (ER) stresses, and trigger programmed cell death (or apoptosis) in the neural folds, resulting in neural tube defects (NTDs) in the embryo. Inhibiting NOS2 can reduce NTDs; however, the underlying mechanisms require further delineation. Targeting NOS2 and associated nitrosative stress using naturally occurring phytochemicals is a potential approach to preventing birth defects in diabetic pregnancies. This study aims to investigate the effect of quercetin-3-glucoside (Q3G), a polyphenol flavonoid found in fruit, in reducing maternal diabetes-induced NTDs in an animal model, and to delineate the molecular mechanisms underlying Q3G action in regulating NOS2 expression. Female mice (C57BL/6) were induced to develop diabetes using streptozotocin before pregnancy. Diabetic pregnant mice were administered Q3G (100 mg/kg) daily via gavage feeding, introduction of drug to the stomach directly via a feeding needle, during neurulation from embryonic (E) day 6.5 to E9.5. After treatment, E10.5 embryos were collected and examined for the presence of NTDs and apoptosis in the neural tube. Expression of Nos2 and superoxide dismutase 1 (Sod1; an antioxidative enzyme) was quantified using Western blot assay. Nitrosative, oxidative, and endoplasmic reticulum (ER) stress conditions were assessed using specific biomarkers. Expression and posttranslational modification of factors in the NF-κB system were investigated. Treatment with Q3G (suspended in water) significantly decreased NTD rate (24.7%) and apoptosis in the embryos of diabetic mice, compared with those in the water-treated diabetic group (3.1%; p<0.001). Q3G decreased the expression of Nos2 and nitrosative stress (p<0.05). It also increased the levels of Sod1 (p<0.05), further increasing the antioxidative capacity of the cells. Q3G treatment also alleviated of ER stress in the embryos of diabetic mice (p<0.05). Q3G reduced the levels of p65 (RelA; p<0.05), a member of the NF-κB transcription factor family, but augmented the levels of the inhibitor of κBα (IκBα; p<0.05), which suppresses p65 nuclear translocation. In association with these changes, the levels of IκB kinase α (Ikkα) and IκBα phosphorylation were elevated (p<0.05). Q3G reduces the NTD rate in the embryos of diabetic dams. Q3G suppresses Nos2 and increases Sod1 expression, leading to alleviation of nitrosative, oxidative, and ER stress conditions. Q3G may regulate the expression of Nos2 via modulating the NF-κB transcription regulation system. Q3G, a naturally occurring polyphenol that has high bioavailability and low toxicity, is a promising candidate agent to prevent birth defects in diabetic pregnancies. The phytochemical quercetin-3-glucoside prevents neural tube defects in embryos of diabetic mice by alleviating nitrosative stress via suppression of the nuclear factor κB-regulated nitric oxide synthase 2 expression. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. First measurement of proton's charge form factor at very low Q2 with initial state radiation

    NASA Astrophysics Data System (ADS)

    Mihovilovič, M.; Weber, A. B.; Achenbach, P.; Beranek, T.; Beričič, J.; Bernauer, J. C.; Böhm, R.; Bosnar, D.; Cardinali, M.; Correa, L.; Debenjak, L.; Denig, A.; Distler, M. O.; Esser, A.; Ferretti Bondy, M. I.; Fonvieille, H.; Friedrich, J. M.; Friščić, I.; Griffioen, K.; Hoek, M.; Kegel, S.; Kohl, Y.; Merkel, H.; Middleton, D. G.; Müller, U.; Nungesser, L.; Pochodzalla, J.; Rohrbeck, M.; Sánchez Majos, S.; Schlimme, B. S.; Schoth, M.; Schulz, F.; Sfienti, C.; Širca, S.; Štajner, S.; Thiel, M.; Tyukin, A.; Vanderhaeghen, M.; Weinriefer, M.

    2017-08-01

    We report on a new experimental method based on initial-state radiation (ISR) in e-p scattering, which exploits the radiative tail of the elastic peak to study the properties of electromagnetic processes and to extract the proton charge form factor (GEp) at extremely small Q2. The ISR technique was implemented in an experiment at the three-spectrometer facility of the Mainz Microtron (MAMI). This led to a precise validation of radiative corrections far away from elastic line and provided first measurements of GEp for 0.001 ≤Q2 ≤ 0.004(GeV / c)2.

  3. Quantitative polymerase chain reaction (PCR) for detection of aquatic animal pathogens in a diagnostic laboratory setting

    USGS Publications Warehouse

    Purcell, Maureen K.; Getchell, Rodman G.; McClure, Carol A.; Weber, S.E.; Garver, Kyle A.

    2011-01-01

    Real-time, or quantitative, polymerase chain reaction (qPCR) is quickly supplanting other molecular methods for detecting the nucleic acids of human and other animal pathogens owing to the speed and robustness of the technology. As the aquatic animal health community moves toward implementing national diagnostic testing schemes, it will need to evaluate how qPCR technology should be employed. This review outlines the basic principles of qPCR technology, considerations for assay development, standards and controls, assay performance, diagnostic validation, implementation in the diagnostic laboratory, and quality assurance and control measures. These factors are fundamental for ensuring the validity of qPCR assay results obtained in the diagnostic laboratory setting.

  4. PRKCDBP (CAVIN3) and CRY2 associate with major depressive disorder.

    PubMed

    Kovanen, Leena; Donner, Kati; Kaunisto, Mari; Partonen, Timo

    2017-01-01

    Dysfunctions in the intrinsic clocks are suggested in patients with depressive disorders. The cryptochrome circadian clocks 1 and 2 (CRY1 and CRY2) proteins modulate circadian rhythms in a cell and influence emotional reactions and mood in an individual. The protein kinase C delta binding protein (PRKCDBP, or CAVIN3), similar to the serum deprivation response protein (SDPR, or CAVIN2), reduces metabolic stability of the PER2-CRY2 transcription factor complex that plays a role in the circadian rhythm synchronization. Our aim was to study SDPR, PRKCDBP, CRY1 and CRY2 genetic variants in depressive disorders. The sample included 5910 Finnish individuals assessed with the Munich-Composite International Diagnostic Interview (M-CIDI) in year 2000. In year 2011, 3424 individuals were assessed again. After genotype quality control, there were 383 subjects with major depressive disorder, 166 with dysthymia, and 479 with depressive disorders (major depressive disorder, dysthymia or both), and 4154 healthy controls. A total of 48 single-nucleotide polymorphisms from SDPR, PRKCDBP, CRY1 and CRY2 genes were analyzed using logistic regression models controlling for age and gender. The earlier reported association of CRY2 variants with dysthymia was confirmed and extended to major depressive disorder (q<0.05). In addition, novel associations of PRKCDBP rs1488864 with depressive disorders (q=0.02) and with major depressive disorder in specific (q=0.007) were found. The number of cases was moderate and coverage of PRKCDB was limited. CRY2 and PRKCDBP variants may be risk factors of major depressive disorder and provide information for diagnosis. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Room-Temperature Pressure-Induced Optically-Actuated Fabry-Perot Nanomechanical Resonator with Multilayer Graphene Diaphragm in Air.

    PubMed

    Li, Cheng; Lan, Tian; Yu, Xiyu; Bo, Nan; Dong, Jingyu; Fan, Shangchun

    2017-11-04

    We demonstrated a miniature and in situ ~13-layer graphene nanomechanical resonator by utilizing a simple optical fiber Fabry-Perot (F-P) interferometric excitation and detection scheme. The graphene film was transferred onto the endface of a ferrule with a 125-μm inner diameter. In contrast to the pre-tension induced in membrane that increased quality ( Q ) factor to ~18.5 from ~3.23 at room temperature and normal pressure, the limited effects of air damping on resonance behaviors at 10 -2 and 10⁵ Pa were demonstrated by characterizing graphene F-P resonators with open and micro-air-gap cavities. Then in terms of optomechanical behaviors of the resonator with an air micro-cavity configuration using a polished ferrule substrate, measured resonance frequencies were increased to the range of 509-542 kHz from several kHz with a maximum Q factor of 16.6 despite the lower Knudsen number ranging from 0.0002 to 0.0006 in damping air over a relative pressure range of 0-199 kPa. However, there was the little dependence of Q on resonance frequency. Note that compared with the inferior F-P cavity length response to applied pressures due to interfacial air leakage, the developed F-P resonator exhibited a consistent fitted pressure sensitivity of 1.18 × 10⁵ kHz³/kPa with a good linearity error of 5.16% in the tested range. These measurements shed light on the pre-stress-dominated pressure-sensitive mechanisms behind air damping in in situ F-P resonant sensors using graphene or other 2D nanomaterials.

  6. Axial-vector form factors of the nucleon from lattice QCD

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gupta, Rajan; Jang, Yong-Chull; Lin, Huey-Wen

    In this paper, we present results for the form factors of the isovector axial vector current in the nucleon state using large scale simulations of lattice QCD. The calculations were done using eight ensembles of gauge configurations generated by the MILC collaboration using the HISQ action with 2 + 1 + 1 dynamical flavors. These ensembles span three lattice spacings a ≈ 0.06 , 0.09, and 0.12 fm and light-quark masses corresponding to the pion masses M π ≈ 135, 225, and 310 MeV. High-statistics estimates allow us to quantify systematic uncertainties in the extraction of G A (Q 2)more » and the induced pseudoscalar form factor G P(Q 2) . We perform a simultaneous extrapolation in the lattice spacing, lattice volume and light-quark masses of the axial charge radius r A data to obtain physical estimates. Using the dipole ansatz to fit the Q 2 behavior we obtain r A | dipole = 0.49(3) fm , which corresponds to M A = 1.39(9) GeV , and is consistent with M A = 1.35(17) GeV obtained by the miniBooNE collaboration. The estimate obtained using the z -expansion is r A | z - expansion = 0.46(6) fm, and the combined result is r A | combined = 0.48(4) fm. Analysis of the induced pseudoscalar form factor G P (Q 2) yields low estimates for g* P and g πNN compared to their phenomenological values. To understand these, we analyze the partially conserved axial current (PCAC) relation by also calculating the pseudoscalar form factor. Lastly, we find that these low values are due to large deviations in the PCAC relation between the three form factors, and in the pion-pole dominance hypothesis.« less

  7. Axial-vector form factors of the nucleon from lattice QCD

    DOE PAGES

    Gupta, Rajan; Jang, Yong-Chull; Lin, Huey-Wen; ...

    2017-12-04

    In this paper, we present results for the form factors of the isovector axial vector current in the nucleon state using large scale simulations of lattice QCD. The calculations were done using eight ensembles of gauge configurations generated by the MILC collaboration using the HISQ action with 2 + 1 + 1 dynamical flavors. These ensembles span three lattice spacings a ≈ 0.06 , 0.09, and 0.12 fm and light-quark masses corresponding to the pion masses M π ≈ 135, 225, and 310 MeV. High-statistics estimates allow us to quantify systematic uncertainties in the extraction of G A (Q 2)more » and the induced pseudoscalar form factor G P(Q 2) . We perform a simultaneous extrapolation in the lattice spacing, lattice volume and light-quark masses of the axial charge radius r A data to obtain physical estimates. Using the dipole ansatz to fit the Q 2 behavior we obtain r A | dipole = 0.49(3) fm , which corresponds to M A = 1.39(9) GeV , and is consistent with M A = 1.35(17) GeV obtained by the miniBooNE collaboration. The estimate obtained using the z -expansion is r A | z - expansion = 0.46(6) fm, and the combined result is r A | combined = 0.48(4) fm. Analysis of the induced pseudoscalar form factor G P (Q 2) yields low estimates for g* P and g πNN compared to their phenomenological values. To understand these, we analyze the partially conserved axial current (PCAC) relation by also calculating the pseudoscalar form factor. Lastly, we find that these low values are due to large deviations in the PCAC relation between the three form factors, and in the pion-pole dominance hypothesis.« less

  8. A comparison of Q-factor estimation methods for marine seismic data

    NASA Astrophysics Data System (ADS)

    Kwon, J.; Ha, J.; Shin, S.; Chung, W.; Lim, C.; Lee, D.

    2016-12-01

    The seismic imaging technique draws information from inside the earth using seismic reflection and transmission data. This technique is an important method in geophysical exploration. Also, it has been employed widely as a means of locating oil and gas reservoirs because it offers information on geological media. There is much recent and active research into seismic attenuation and how it determines the quality of seismic imaging. Seismic attenuation is determined by various geological characteristics, through the absorption or scattering that occurs when the seismic wave passes through a geological medium. The seismic attenuation can be defined using an attenuation coefficient and represented as a non-dimensional variable known as the Q-factor. Q-factor is a unique characteristic of a geological medium. It is a very important material property for oil and gas resource development. Q-factor can be used to infer other characteristics of a medium, such as porosity, permeability and viscosity, and can directly indicate the presence of hydrocarbons to identify oil and gas bearing areas from the seismic data. There are various ways to estimate Q-factor in three different domains. In the time domain, pulse amplitude decay, pulse rising time, and pulse broadening are representative. Logarithm spectral ratio (LSR), centroid frequency shift (CFS), and peak frequency shift (PFS) are used in the frequency domain. In the time-frequency domain, Wavelet's Envelope Peak Instantaneous Frequency (WEPIF) is most frequently employed. In this study, we estimated and analyzed the Q-factor through the numerical model test and used 4 methods: the LSR, CFS, PFS, and WEPIF. Before we applied these 4 methods to observed data, we experimented with the numerical model test. The numerical model test data is derived from Norsar-2D, which is the basis of the ray-tracing algorithm, and we used reflection and normal incidence surveys to calculate Q-factor according to the array of sources and receivers. After the numerical model test, we chose the most accurate of the 4 methods by comparing Q-factor through reflection and normal incidence surveys. We applied the method to the observed data and proved its accuracy.

  9. Novel mathematic models for quantitative transitivity of quality-markers in extraction process of the Buyanghuanwu decoction.

    PubMed

    Zhang, Yu-Tian; Xiao, Mei-Feng; Deng, Kai-Wen; Yang, Yan-Tao; Zhou, Yi-Qun; Zhou, Jin; He, Fu-Yuan; Liu, Wen-Long

    2018-06-01

    Nowadays, to research and formulate an efficiency extraction system for Chinese herbal medicine, scientists have always been facing a great challenge for quality management, so that the transitivity of Q-markers in quantitative analysis of TCM was proposed by Prof. Liu recently. In order to improve the quality of extraction from raw medicinal materials for clinical preparations, a series of integrated mathematic models for transitivity of Q-markers in quantitative analysis of TCM were established. Buyanghuanwu decoction (BYHWD) was a commonly TCMs prescription, which was used to prevent and treat the ischemic heart and brain diseases. In this paper, we selected BYHWD as an extraction experimental subject to study the quantitative transitivity of TCM. Based on theory of Fick's Rule and Noyes-Whitney equation, novel kinetic models were established for extraction of active components. Meanwhile, fitting out kinetic equations of extracted models and then calculating the inherent parameters in material piece and Q-marker quantitative transfer coefficients, which were considered as indexes to evaluate transitivity of Q-markers in quantitative analysis of the extraction process of BYHWD. HPLC was applied to screen and analyze the potential Q-markers in the extraction process. Fick's Rule and Noyes-Whitney equation were adopted for mathematically modeling extraction process. Kinetic parameters were fitted and calculated by the Statistical Program for Social Sciences 20.0 software. The transferable efficiency was described and evaluated by potential Q-markers transfer trajectory via transitivity availability AUC, extraction ratio P, and decomposition ratio D respectively. The Q-marker was identified with AUC, P, D. Astragaloside IV, laetrile, paeoniflorin, and ferulic acid were studied as potential Q-markers from BYHWD. The relative technologic parameters were presented by mathematic models, which could adequately illustrate the inherent properties of raw materials preparation and affection of Q-markers transitivity in equilibrium processing. AUC, P, D for potential Q-markers of AST-IV, laetrile, paeoniflorin, and FA were obtained, with the results of 289.9 mAu s, 46.24%, 22.35%; 1730 mAu s, 84.48%, 1.963%; 5600 mAu s, 70.22%, 0.4752%; 7810 mAu s, 24.29%, 4.235%, respectively. The results showed that the suitable Q-markers were laetrile and paeoniflorin in our study, which exhibited acceptable traceability and transitivity in the extraction process of TCMs. Therefore, these novel mathematic models might be developed as a new standard to control TCMs quality process from raw medicinal materials to product manufacturing. Copyright © 2018 Elsevier GmbH. All rights reserved.

  10. Contribution of the neighborhood environment and obesity to breast cancer survival: the California Breast Cancer Survivorship Consortium.

    PubMed

    Cheng, Iona; Shariff-Marco, Salma; Koo, Jocelyn; Monroe, Kristine R; Yang, Juan; John, Esther M; Kurian, Allison W; Kwan, Marilyn L; Henderson, Brian E; Bernstein, Leslie; Lu, Yani; Sposto, Richard; Vigen, Cheryl; Wu, Anna H; Gomez, Scarlett Lin; Keegan, Theresa H M

    2015-08-01

    Little is known about neighborhood attributes that may influence opportunities for healthy eating and physical activity in relation to breast cancer mortality. We used data from the California Breast Cancer Survivorship Consortium and the California Neighborhoods Data System (CNDS) to examine the neighborhood environment, body mass index, and mortality after breast cancer. We studied 8,995 African American, Asian American, Latina, and non-Latina white women with breast cancer. Residential addresses were linked to the CNDS to characterize neighborhoods. We used multinomial logistic regression to evaluate the associations between neighborhood factors and obesity and Cox proportional hazards regression to examine associations between neighborhood factors and mortality. For Latinas, obesity was associated with more neighborhood crowding [quartile 4 (Q4) vs. Q1: OR, 3.24; 95% confidence interval (CI), 1.50-7.00]; breast cancer-specific mortality was inversely associated with neighborhood businesses (Q4 vs. Q1: HR, 0.46; 95% CI, 0.25-0.85) and positively associated with multifamily housing (Q3 vs. Q1: HR, 1.98; 95% CI, 1.20-3.26). For non-Latina whites, lower neighborhood socioeconomic status (SES) was associated with obesity [quintile 1 (Q1) vs. Q5: OR, 2.52; 95% CI, 1.31-4.84], breast cancer-specific (Q1 vs. Q5: HR, 2.75; 95% CI, 1.47-5.12), and all-cause (Q1 vs. Q5: HR, 1.75; 95% CI, 1.17-2.62) mortality. For Asian Americans, no associations were seen. For African Americans, lower neighborhood SES was associated with lower mortality in a nonlinear fashion. Attributes of the neighborhood environment were associated with obesity and mortality following breast cancer diagnosis, but these associations differed across racial/ethnic groups. ©2015 American Association for Cancer Research.

  11. Contribution of the Neighborhood Environment and Obesity to Breast Cancer Survival: The California Breast Cancer Survivorship Consortium

    PubMed Central

    Cheng, Iona; Shariff-Marco, Salma; Koo, Jocelyn; Monroe, Kristine R.; Yang, Juan; John, Esther M.; Kurian, Allison W.; Kwan, Marilyn L.; Henderson, Brian E.; Bernstein, Leslie; Lu, Yani; Sposto, Richard; Vigen, Cheryl; Wu, Anna H.; Gomez, Scarlett Lin; Keegan, Theresa H.M.

    2015-01-01

    Little is known about neighborhood attributes that may influence opportunities for healthy eating and physical activity in relation to breast cancer mortality. We used data from the California Breast Cancer Survivorship Consortium and the California Neighborhoods Data System to examine the neighborhood environment, body mass index, and mortality after breast cancer. We studied 8,995 African American, Asian American, Latina, and non-Latina White women with breast cancer. Residential addresses were linked to the CNDS to characterize neighborhoods. We used multinomial logistic regression to evaluate the associations between neighborhood factors and obesity, and Cox proportional hazards regression to examine associations between neighborhood factors and mortality. For Latinas, obesity was associated with more neighborhood crowding (Quartile 4 (Q4) vs. Q1: Odds Ratio (OR)=3.24; 95% Confidence Interval (CI): 1.50-7.00); breast cancer-specific mortality was inversely associated with neighborhood businesses (Q4 vs. Q1: Hazard Ratio (HR)=0.46; 95% CI: 0.25-0.85) and positively associated with multi-family housing (Q3 vs. Q1: HR=1.98; 95% CI: 1.20-3.26). For non-Latina Whites, lower neighborhood socioeconomic status (SES) was associated with obesity (Quintile 1 (Q1) vs. Q5: OR=2.52; 95% CI: 1.31-4.84), breast cancer-specific (Q1 vs. Q5: HR=2.75; 95% CI: 1.47-5.12), and all-cause (Q1 vs. Q5: HR=1.75; 95% CI: 1.17-2.62) mortality. For Asian Americans, no associations were seen. For African Americans, lower neighborhood SES was associated with lower mortality in a nonlinear fashion. Attributes of the neighborhood environment were associated with obesity and mortality following breast cancer diagnosis, but these associations differed across racial/ethnic groups. PMID:26063477

  12. Shielded microstrip array for 7T human MR imaging.

    PubMed

    Wu, Bing; Wang, Chunsheng; Kelley, Douglas A C; Xu, Duan; Vigneron, Daniel B; Nelson, Sarah J; Zhang, Xiaoliang

    2010-01-01

    The high-frequency transceiver array based on the microstrip transmission line design is a promising technique for ultrahigh field magnetic resonance imaging (MRI) signal excitation and reception. However, with the increase of radio-frequency (RF) channels, the size of the ground plane in each microstrip coil element is usually not sufficient to provide a perfect ground. Consequently, the transceiver array may suffer from cable resonance, lower Q-factors, and imaging quality degradations. In this paper, we present an approach to improving the performance of microstrip transceiver arrays by introducing RF shielding outside the microstrip array and the feeding coaxial cables. This improvement reduced interactions among cables, increased resonance stability, and Q-factors, and thus improved imaging quality. An experimental method was also introduced and utilized for quantitative measurement and evaluation of RF coil resonance stability or "cable resonance" behavior.

  13. Shielded Microstrip Array for 7T Human MR Imaging

    PubMed Central

    Wu, Bing; Wang, Chunsheng; Kelley, Douglas A. C.; Xu, Duan; Vigneron, Daniel B.; Nelson, Sarah J.

    2010-01-01

    The high-frequency transceiver array based on the microstrip transmission line design is a promising technique for ultrahigh field magnetic resonance imaging (MRI) signal excitation and reception. However, with the increase of radio-frequency (RF) channels, the size of the ground plane in each microstrip coil element is usually not sufficient to provide a perfect ground. Consequently, the transceiver array may suffer from cable resonance, lower Q-factors, and imaging quality degradations. In this paper, we present an approach to improving the performance of microstrip transceiver arrays by introducing RF shielding outside the microstrip array and the feeding coaxial cables. This improvement reduced interactions among cables, increased resonance stability, and Q-factors, and thus improved imaging quality. An experimental method was also introduced and utilized for quantitative measurement and evaluation of RF coil resonance stability or “cable resonance” behavior. PMID:19822470

  14. A parameter quantifying radiation damping of bay oscillations excited by incident tsunamis

    NASA Astrophysics Data System (ADS)

    Endoh, Takahiro; Inazu, Daisuke; Waseda, Takuji; Hibiya, Toshiyuki

    2018-04-01

    The transient response of a bay with a narrow mouth to incident tsunamis is interpreted as the convolution of the input signal with the impulse response obtained by an inverse Fourier transform of the response curve of the oscillatory system with one degree of freedom. The rate of radiation damping associated with energy escaping seaward through the bay mouth is expressed in terms of the quality factor Q, which determines the decaying envelope of the impulse response. The value of Q of the resonant peak is approximated by the ratio of the resonant frequency ω0 to the bandwidth between frequencies at which the power spectral density of sea level within the bay drops to half of the peak value. Since the shape of the frequency power spectrum during the tsunami event is almost similar to that in the normal state in the neighborhood of ω0, Q can be estimated from sea level datasets in the normal state. Although the amplitude and phase of the impulse response need to be adjusted using the first crest or trough of the observed leading wave, this approach proves to work well in examining the transient responses of Miyako Bay and Kushimoto Bay on the Japanese Pacific coast to incident tsunamis.

  15. Plasma zinc in institutionalized elderly individuals: Relation with immune and cardiometabolic biomarkers.

    PubMed

    Sales, Márcia Cristina; de Oliveira, Larissa Praça; de Araújo Cabral, Natalia Louise; de Sousa, Sara Estéfani Soares; das Graças Almeida, Maria; Lemos, Telma Maria Araújo Moura; de Oliveira Lyra, Clélia; de Lima, Kenio Costa; Sena-Evangelista, Karine Cavalcanti Mauricio; de Fatima Campos Pedrosa, Lucia

    2018-04-24

    Changes in zinc metabolism caused by aging and the institutionalization process may contribute to zinc deficiency in elderly individuals. Hypozincemia results in changes in glycemic, lipid, and inflammatory profiles. The aim of this study was to evaluate plasma zinc concentrations and their relationships with sociodemographic, dietary, inflammatory, and cardiometabolic biomarkers in institutionalized elderly individuals. A cross-sectional study was carried out including 255 elderly adults living in nursing homes. The associations between plasma zinc and dietary zinc intake, sociodemographic indicators, and glycemic, lipid, and inflammatory biomarkers were evaluated. Independent variables were analyzed according to quartiles of plasma zinc concentrations (Q1: <71.1 μg/dL; Q2: 71.1-83.3 μg/dL; Q3: <83.3-93.7 μg/dL; Q4: >93.7 μg/dL). The relationship between plasma zinc concentrations and predictor variables was also tested. In Q1, higher concentrations of the following variables were observed, compared with those in other quartiles: total cholesterol and low-density lipoprotein cholesterol (LDL-c; Q1 > Q2, Q3, Q4; all p <0.001); triglycerides (Q1 > Q3, Q4; all p < 0.001); interleukin (IL)-6 (Q1 > Q3, Q4; p = 0.024 and p = 0.010, respectively); tumor necrosis factor (TNF)-α (Q1 > Q3, p = 0.003). A significant reduction in plasma zinc concentrations was observed with increasing age-adjusted institutionalization time (Δ = - 0.10; 95% confidence interval [CI]: -0.18 to -0.01). The concentrations of total cholesterol (Δ = - 0.19; 95% CI: -0.23 to -0.15), LDL-c (Δ = - 0.19; 95% CI: -0.23 to -0.15), triglycerides (Δ = - 0.11; 95% CI: -0.16 to -0.06), IL-6 (Δ = - 1.41; 95% CI: -2.64 to -0.18), and TNF-α (Δ = - 1.04; 95% CI: -1.71 to -0.36) were also significantly increased. In conclusion, decreased plasma zinc concentrations were associated with longer institutionalization time and worse lipid and inflammatory profiles in elderly institutionalized individuals. Published by Elsevier GmbH.

  16. Direct observation of the topological spin configurations mediated by the substitution of rare-earth element Y in MnNiGa alloy.

    PubMed

    Zuo, S L; Zhang, Y; Peng, L C; Zhao, X; Li, R; Li, H; Xiong, J F; He, M; Zhao, T Y; Sun, J R; Hu, F X; Shen, B G

    2018-02-01

    The evolution of topological magnetic domains microscopically correlates the dynamic behavior of memory units in spintronic application. Nanometric bubbles with variation of spin configurations have been directly observed in a centrosymmetric hexagonal magnet (Mn 0.5 Ni 0.5 ) 65 (Ga 1-y Y y ) 35 (y = 0.01) using Lorentz transmission electron microscopy. Magnetic bubbles instead of biskyrmions are generated due to the enhancement of quality factor Q caused by the substitution of rare-earth element Y. Furthermore, the bubble density and diversified spin configurations are systematically manipulated via combining the electric current with perpendicular magnetic fields. The magnetic bubble lattice at zero field is achieved after the optimized manipulation.

  17. S-wave attenuation in northeastern Sonora, Mexico, near the faults that ruptured during the earthquake of 3 May 1887 Mw 7.5.

    PubMed

    Villalobos-Escobar, Gina P; Castro, Raúl R

    2014-01-01

    We used a new data set of relocated earthquakes recorded by the Seismic Network of Northeastern Sonora, Mexico (RESNES) to characterize the attenuation of S-waves in the fault zone of the 1887 Sonora earthquake (M w 7.5). We determined spectral attenuation functions for hypocentral distances (r) between 10 and 140 km using a nonparametric approach and found that in this fault zone the spectral amplitudes decay slower with distance at low frequencies (f < 4 Hz) compared to those reported in previous studies in the region using more distant recordings. The attenuation functions obtained for 23 frequencies (0.4 ≤ f ≤ 63.1 Hz) permit us estimating the average quality factor Q S  = (141 ± 1.1 )f ((0.74 ± 0.04)) and a geometrical spreading term G(r) = 1/r (0.21). The values of Q estimated for S-wave paths traveling along the fault system that rupture during the 1887 event, in the north-south direction, are considerably lower than the average Q estimated using source-station paths from multiple stations and directions. These results indicate that near the fault zone S waves attenuate considerably more than at regional scale, particularly at low frequencies. This may be the result of strong scattering near the faults due to the fractured upper crust and higher intrinsic attenuation due to stress concentration near the faults.

  18. Dietary patterns are associated with cognitive function in the REasons for Geographic And Racial Differences in Stroke (REGARDS) cohort.

    PubMed

    Pearson, Keith E; Wadley, Virginia G; McClure, Leslie A; Shikany, James M; Unverzagt, Fred W; Judd, Suzanne E

    2016-01-01

    Identifying factors that contribute to the preservation of cognitive function is imperative to maintaining quality of life in advanced years. Of modifiable risk factors, diet quality has emerged as a promising candidate to make an impact on cognition. The objective of this study was to evaluate associations between empirically derived dietary patterns and cognitive function. This study included 18 080 black and white participants aged 45 years and older from the REasons for Geographic And Racial Differences in Stroke (REGARDS) cohort. Principal component analysis on data from the Block98 FFQ yielded five dietary patterns: convenience, plant-based, sweets/fats, Southern, and alcohol/salads. Incident cognitive impairment was defined as shifting from intact cognitive status (score >4) at first assessment to impaired cognitive status (score ≤4) at latest assessment, measured by the Six-Item Screener. Learning, memory and executive function were evaluated with the Word List Learning, Word List Delayed Recall, and animal fluency assessments. In fully adjusted models, greater consumption of the alcohol/salads pattern was associated with lower odds of incident cognitive impairment (highest quintile (Q5) v . lowest quintile (Q1): OR 0·68; 95 % CI 0·56, 0·84; P for trend 0·0005). Greater consumption of the alcohol/salads pattern was associated with higher scores on all domain-specific assessments and greater consumption of the plant-based pattern was associated with higher scores in learning and memory. Greater consumption of the Southern pattern was associated with lower scores on each domain-specific assessment (all P  < 0·05). In conclusion, dietary patterns including plant-based foods and alcohol intake were associated with higher cognitive scores, and a pattern including fried food and processed meat typical of a Southern diet was associated with lower scores.

  19. Identifying Key Components for an Effective Case Report Poster: An Observational Study

    PubMed Central

    Paranjape, Anuradha; Estrada, Carlos

    2008-01-01

    BACKGROUND Residents demonstrate scholarly activity by presenting posters at academic meetings. Although recommendations from national organizations are available, evidence identifying which components are most important is not. OBJECTIVE To develop and test an evaluation tool to measure the quality of case report posters and identify the specific components most in need of improvement. DESIGN Faculty evaluators reviewed case report posters and provided on-site feedback to presenters at poster sessions of four annual academic general internal medicine meetings. A newly developed ten-item evaluation form measured poster quality for specific components of content, discussion, and format (5-point Likert scale, 1 = lowest, 5 = highest). Main outcome measure(s): Evaluation tool performance, including Cronbach alpha and inter-rater reliability, overall poster scores, differences across meetings and evaluators and specific components of the posters most in need of improvement. RESULTS Forty-five evaluators from 20 medical institutions reviewed 347 posters. Cronbach’s alpha of the evaluation form was 0.84 and inter-rater reliability, Spearman’s rho 0.49 ( < 0.001). The median score was 4.1 (Q1 -Q3, 3.7-4.6)(Q1 = 25th, Q3 = 75th percentile). The national meeting median score was higher than the regional meetings (4.4 vs, 4.0,  < 0.001). We found no difference in faculty scores. The following areas were identified as most needing improvement: clearly state learning objectives, tie conclusions to learning objectives, and use appropriate amount of words. CONCLUSIONS Our evaluation tool provides empirical data to guide trainees as they prepare posters for presentation which may improve poster quality and enhance their scholarly productivity. PMID:19089510

  20. Prognostic Markers in Core-Binding Factor AML and Improved Survival with Multiple Consolidation Cycles of Intermediate/High-dose Cytarabine.

    PubMed

    Prabahran, Ashvind; Tacey, Mark; Fleming, Shaun; Wei, Andrew; Tate, Courtney; Marlton, Paula; Wight, Joel; Grigg, Andrew; Tuckfield, Annabel; Szer, Jeff; Ritchie, David; Chee, Lynette

    2018-05-02

    Core-binding factor acute myeloid leukaemia (CBF AML) defined by t(8;21)(q22;q22) or inv(16)(p13q22)/t(16;16)(p13;q22) has a favourable prognosis, however 30-40% of patients still relapse after chemotherapy. We sought to evaluate risk factors for relapse in a de novo CBF AML cohort. A retrospective review of patients from 4 Australian tertiary centres from 2001-2012, comprising 40 t(8;21) and 30 inv(16) AMLs. Multivariate analysis identified age (p=0.032) and WCC>40 (p=0.025) as significant predictors for inferior OS and relapse respectively. Relapse risk was higher in the inv(16) group vs the t(8;21) group (57% vs 18%, HR 4.31, 95% CI: 1.78-10.42, p=0.001). Induction therapy had no bearing on OS or relapse free survival (RFS) however, consolidation treatment with >3 cycles of intermediate/high dose cytarabine improved OS (p=0.035) and relapse-free survival (RFS) (p=0.063). 5 patients demonstrated post-treatment stable q PCR positivity without relapse. (1)>3 consolidation cycles of intermediate/ high-dose cytarabine improves patient outcomes. (2)Age and inv(16) CBF AML subtype are predictors of inferior OS and RFS respectively. (3)Stable low-level MRD by qPCR does not predict relapse. (4)Similar OS in the inv(16) cohort compared to the t(8;21) cohort, despite a higher relapse rate, confirms salvageability of relapsed disease. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  1. Theory of coupled resonator optical waveguides exhibiting high-order exceptional points of degeneracy

    NASA Astrophysics Data System (ADS)

    Nada, Mohamed Y.; Othman, Mohamed A. K.; Capolino, Filippo

    2017-11-01

    We present an approach and a theoretical framework for generating high-order exceptional points of degeneracy (EPDs) in photonic structures based on periodic coupled resonator optical waveguides (CROWs). Such EPDs involve the coalescence of Floquet-Bloch eigenwaves in CROWs, without the presence of gain and loss, which contrasts with the parity-time symmetry required to develop exceptional points based on gain and loss balance. The EPDs arise here by introducing symmetry breaking in a conventional chain of coupled resonators through periodic coupling to an adjacent uniform optical waveguide, which leads to unique modal characteristics that cannot be realized in conventional CROWs. Such remarkable characteristics include high quality factors (Q factors) and strong field enhancement, even without any mirrors at the two ends of a cavity. We show for the first time the capability of CROWs to exhibit EPDs of various orders, including the degenerate band edge (DBE) and the stationary inflection point. The proposed CROW of finite length shows an enhanced quality factor when operating near the DBE, and the Q factor exhibits an unconventional scaling with the CROW's length. We develop the theory of EPDs in such unconventional CROW using coupled-wave equations, and we derive an analytical expression for the dispersion relation. The proposed unconventional CROW concepts have various potential applications including Q switching, nonlinear devices, lasers, and extremely sensitive sensors.

  2. Electromagnetically induced transparency in planar metamaterials based on guided mode resonance

    NASA Astrophysics Data System (ADS)

    Sun, Yaru; Chen, Hang; Li, Xiangjun; Hong, Zhi

    2017-06-01

    We present and numerically demonstrate a novel, electromagnetically induced transparency (EIT) in planar metamaterials (MMs) based on guided mode resonance (GMR). The unit cell of the MM consists of two metallic ring resonators. The GMR with high quality factor (Q) is achieved by changing the distance between the two rings of the MM. Narrow EIT-like spectral response is realized by coupling between a high Q GMR and a low Q dipolar resonance of the MM. Our work could provide another efficient way towards the realization of EIT with large group index using very simple structures.

  3. EDITORIAL: Are higher quality papers cited more often? Are higher quality papers cited more often?

    NASA Astrophysics Data System (ADS)

    Patterson, Michael S.; Harris, Simon

    2009-09-01

    Most researchers are aware of the increasing emphasis placed on citations as an indicator of quality by their colleagues, as well as by administrators and librarians. But is it true that high quality papers are cited more often? In what we believe to be the only previous publication to examine this question, West and McIlwaine (2002) selected 79 papers that had been published in the journal Addiction in 1997. These papers were rated by an assistant editor of the journal on a five-level quality scale (ranging from 'among the top 10%' to 'should not have been published') as well as a second 'blind' rater. The authors found that the number of citations to each paper from 1997 to 2000 did not correlate with the mean score of the two reviewers, the score assigned by the editors, or the score assigned by the blind referees. The peer-review system used by Physics in Medicine and Biology (PMB) facilitates a larger, prospective study with much less effort. In general, two reviewers are asked to assign each paper a score of 1 to 10 in each of three categories: originality, soundness and significance. The total scores (out of 30) are averaged and on this basis manuscripts are given a quality rating from Q1 (highest quality) to Q5. In a paper recently published in Scientometrics (Patterson and Harris 2009), we compared the number of citations to papers published in PMB in 2003, 2004 and 2005 to the mean quality rating assigned by the reviewers. In total, data were analyzed for 1095 published papers. For each year we found that there was a low but statistically robust correlation between citations and quality rating: for 2003, -0.227 (p < 0.001); for 2004, -0.238 (p < 0.001), and for 2005, -0.154 (p < 0.01). The low correlation means that it is not possible to predict the citation frequency of an individual paper with accuracy but, as a group, the highest ranked papers were cited about twice as often as the average for all published papers. We also examined the data retrospectively by dividing the papers published in each year into five citation quintiles. A paper of the highest quality (Q1) was about ten times more likely to be found in the most-cited quintile than in the least-cited. While it is reassuring to find that the best papers in PMB are, indeed, cited more often on average, we cannot discount the hypothesis that both measures might be influenced by an extrinsic factor, such as the reputation of the authors. We suggest that a study similar to ours be performed for a journal that utilizes a system of double-blind peer review. Michael S Patterson Editorial Board Member Simon Harris Publisher References West R and McIlwaine A 2002 What do citation counts count for in the field of addiction? An empirical evaluation of citation counts and their link with peer ratings of quality Addiction 97 501-4 Patterson M S and Harris S 2009 The relationship between reviewers' quality-scores and number of citations for papers published in the journal Physics in Medicine and Biology from 2003-2005 Scientometrics 80 343-9

  4. Hybrid photonic crystal cavity and waveguide for coupling to diamond NV-centers.

    PubMed

    Barclay, Paul E; Fu, Kai-Mei; Santori, Charles; Beausoleil, Raymond G

    2009-06-08

    A design for an ultra-high Q photonic crystal nanocavity engineered to interact with nitrogen-vacancy (NV) centers located near the surface of a single crystal diamond sample is presented. The structure is based upon a nanowire photonic crystal geometry, and consists of a patterned high refractive index thin film, such as gallium phosphide (GaP), supported by a diamond substrate. The nanocavity supports a mode with quality factor Q > 1.5 x 10(6) and mode volume V < 0.52(lambda/nGaP)(3), and promises to allow Purcell enhanced collection of spontaneous emission from an NV located more than 50 nm below the diamond surface. The nanowire photonic crystal waveguide can be used to efficiently couple light into and out of the cavity, or as an efficient broadband collector of NV phonon sideband emission. The proposed structures can be fabricated using existing materials and processing techniques.

  5. Reduction of Simulation Times for High-Q Structures using the Resonance Equation

    DOE PAGES

    Hall, Thomas Wesley; Bandaru, Prabhakar R.; Rees, Daniel Earl

    2015-11-17

    Simulating steady state performance of high quality factor (Q) resonant RF structures is computationally difficult for structures with sizes on the order of more than a few wavelengths because of the long times (on the order of ~ 0.1 ms) required to achieve steady state in comparison with maximum time step that can be used in the simulation (typically, on the order of ~ 1 ps). This paper presents analytical and computational approaches that can be used to accelerate the simulation of the steady state performance of such structures. The basis of the proposed approach is the utilization of amore » larger amplitude signal at the beginning to achieve steady state earlier relative to the nominal input signal. Finally, the methodology for finding the necessary input signal is then discussed in detail, and the validity of the approach is evaluated.« less

  6. Attenuation of Lg waves in the New Madrid seismic zone of the central United States using the coda normalization method

    NASA Astrophysics Data System (ADS)

    Nazemi, Nima; Pezeshk, Shahram; Sedaghati, Farhad

    2017-08-01

    Unique properties of coda waves are employed to evaluate the frequency dependent quality factor of Lg waves using the coda normalization method in the New Madrid seismic zone of the central United States. Instrument and site responses are eliminated and source functions are isolated to construct the inversion problem. For this purpose, we used 121 seismograms from 37 events with moment magnitudes, M, ranging from 2.5 to 5.2 and hypocentral distances from 120 to 440 km recorded by 11 broadband stations. A singular value decomposition (SVD) algorithm is used to extract Q values from the data, while the geometric spreading exponent is assumed to be a constant. Inversion results are then fitted with a power law equation from 3 to 12 Hz to derive the frequency dependent quality factor function. The final results of the analysis are QVLg (f) = (410 ± 38) f0.49 ± 0.05 for the vertical component and QHLg (f) = (390 ± 26) f0.56 ± 0.04 for the horizontal component, where the term after ± sign represents one standard error. For stations within the Mississippi embayment with an average sediment depth of 1 km around the Memphis metropolitan area, estimation of quality factor using the coda normalization method is not well-constrained at low frequencies (f < 3 Hz). There may be several reasons contributing to this issue, such as low frequency surface wave contamination, site effects, or even a change in coda wave scattering regime which can exacerbate the scatter of the data.

  7. Modeling of High-Quality Factor XNOR Gate Using Quantum-Dot Semiconductor Optical Amplifiers at 1 Tb/s

    NASA Astrophysics Data System (ADS)

    Kotb, Amer

    2015-06-01

    The modeling of all-optical logic XNOR gate is realized by a series combination of XOR and INVERT gates. This Boolean function is simulated by using Mach-Zehnder interferometers (MZIs) utilizing quantum-dots semiconductor optical amplifiers (QDs-SOAs). The study is carried out when the effect of amplified spontaneous emission (ASE) is included. The dependence of the output quality factor ( Q-factor) on signals and QDs-SOAs' parameters is also investigated and discussed. The simulation is conducted under a repetition rate of ˜1 Tb/s.

  8. High quality factor, fully switchable terahertz superconducting metasurface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scalari, G., E-mail: scalari@phys.ethz.ch; Maissen, C.; Faist, J.

    2014-12-29

    We present a complementary THz metasurface realised with Niobium thin film which displays a quality factor Q = 54 and a fully switchable behaviour as a function of the temperature. The switching behaviour and the high quality factor are due to a careful design of the metasurface aimed at maximising the ohmic losses when the Nb is above the critical temperature and minimising the radiative coupling. The superconductor allows the operation of the cavity with high Q and the use of inductive elements with a high aspect ratio. Comparison with three dimensional finite element simulations highlights the crucial role of the inductivemore » elements and of the kinetic inductance of the Cooper pairs in achieving the high quality factor and the high field enhancement.« less

  9. MicroElectroMechanical devices and fabrication technologies for radio-frequency analog signal processing

    NASA Astrophysics Data System (ADS)

    Young, Darrin Jun

    The proliferation of wireless services creates a pressing need for compact and low cost RF transceivers. Modern sub-micron technologies provide the active components needed for miniaturization but fail to deliver high quality passives needed in oscillators and filters. This dissertation demonstrates procedures for adding high quality inductors and tunable capacitors to a standard silicon integrated circuits. Several voltage-controlled oscillators operating in the low Giga-Hertz range demonstrate the suitability of these components for high performance RF building blocks. Two low-temperature processes are described to add inductors and capacitors to silicon ICs. A 3-D coil geometry is used for the inductors rather than the conventional planar spiral to substantially reduce substrate loss and hence improve the quality factor and self-resonant frequency. Measured Q-factors at 1 GHz are 30 for a 4.8 nH device, 16 for 8.2 nH and 13.8 nH inductors. Several enhancements are proposed that are expected to result in a further improvement of the achievable Q-factor. This research investigates the design and fabrication of silicon-based IC-compatible high-Q tunable capacitors and inductors. The goal of this investigation is to develop a monolithic low phase noise radio-frequency voltage-controlled oscillator using these high-performance passive components for wireless communication applications. Monolithic VCOs will help the miniaturization of current radio transceivers, which offers a potential solution to achieve a single hand-held wireless phone with multistandard capabilities. IC-compatible micromachining fabrication technologies have been developed to realize on-chip high-Q RF tunable capacitors and 3-D coil inductors. The capacitors achieve a nominal capacitance value of 2 pF and can be tuned over 15% with 3 V. A quality factor over 60 has been measured at 1 GHz. 3-D coil inductors obtain values of 4.8 nH, 8.2 nH and 13.8 nH. At 1 GHz a Q factor of 30 has been achieved for a 4.8 nH device and a Q of 16 for 8.2 nH and 13.8 nH inductors. A prototype RF voltage-controlled oscillator has been implemented employing the micromachined tunable capacitors and a 8.2 nH 3-D coil inductor. The active electronics, tunable capacitors and inductor are fabricated on separated silicon substrates and wire bonded to form the VCO. This hybrid approach is used to avoid the complexity of building the prototype oscillator. Both passive components are fabricated on silicon substrates and thus amenable to monolithic integration with standard IC process. The VCO achieves a -136 dBc/Hz phase noise at a 3 MHz offset frequency from the carrier, suitable for most wireless communication applications and is tunable from 855 MHz to 863 MHz with 3 V.

  10. Scalar and vector form factors of D →π (K )ℓν decays with Nf=2 +1 +1 twisted fermions

    NASA Astrophysics Data System (ADS)

    Lubicz, V.; Riggio, L.; Salerno, G.; Simula, S.; Tarantino, C.; ETM Collaboration

    2017-09-01

    We present a lattice determination of the vector and scalar form factors of the D →π ℓν and D →K ℓν semileptonic decays, which are relevant for the extraction of the CKM matrix elements |Vc d| and |Vc s| from experimental data. Our analysis is based on the gauge configurations produced by the European Twisted Mass Collaboration with Nf=2 +1 +1 flavors of dynamical quarks, at three different values of the lattice spacing (a ≃0.062 ,0.082 ,0.089 fm ) and with pion masses as small as 210 MeV. Quark momenta are injected on the lattice using nonperiodic boundary conditions. The matrix elements of both vector and scalar currents are determined for plenty of kinematical conditions in which parent and child mesons are either moving or at rest. Lorentz symmetry breaking due to hypercubic effects is clearly observed in the data and included in the decomposition of the current matrix elements in terms of additional form factors. After the extrapolations to the physical pion mass and to the continuum limit, we determine the vector and scalar form factors in the whole kinematical region from q2=0 up to qmax2=(MD-Mπ (K ))2 accessible in the experiments, obtaining a good overall agreement with experiments, except in the region at high values of q2 where some deviations are visible. A set of synthetic data points, representing our results for f+Dπ (K )(q2) and f0D π (K )(q2) for several selected values of q2, is provided and also the corresponding covariance matrix is available. At zero four-momentum transfer, we get f+D→π(0 )=0.612 (35 ) and f+D→K(0 )=0.765 (31 ). Using the experimental averages for |Vc d|f+D→π(0 ) and |Vc s|f+D→K(0 ), we extract |Vc d|=0.2330 (137 ) and |Vc s|=0.945 (38 ), respectively. The second row of the CKM matrix is found to be in agreement with unitarity within the current uncertainties: |Vc d|2+|Vc s|2+|Vc b|2=0.949 (78 ).

  11. 76 FR 57746 - Conference on the International Conference on Harmonisation Q10 Pharmaceutical Quality System: A...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-16

    ... ``Pharmaceutical Quality System (ICH Q10) Conference: A Practical Approach to Effective Life- Cycle Implementation... Pharmaceutical Quality System across the product life cycle according to the ICH Q10 model. These companies are...] Conference on the International Conference on Harmonisation Q10 Pharmaceutical Quality System: A Practical...

  12. Restless Legs Syndrome in Adults in Peking Union Medical College Hospital.

    PubMed

    Chen, Jian-Hua; Huang, Rong; Luo, Jin-Mei; Xiao, Yi; Zhong, Xu; Liu, Xiu-Qin

    2016-10-10

    Objective To investigate the clinical characteristics of restless legs syndrome (RLS) in adults in Peking Union Medical College Hospital and explore the sleep quality,fatigue degree,daytime sleepiness,disease severity,depression and anxiety of RLS patients.Methods Totally 4739 consecutive patients who visited the outpatient departments with any sleep complaint or leg discomforts were recruited in the study. Patients under 18 years were excluded. All participants answered RLS questionnaire. The subjects fulfilled all four criteria would be followed up and given advanced examinations to rule out secondary RLS and RLS mimics. Primary RLS patients were evaluated with International Restless Legs Scale (IRLS),Pittsburgh Sleep Quality Index (PSQI),Fatigue Severity Scale (FSS),Epworth Sleepiness Scale (ESS),and Hospital Anxiety and Depression Scale for depression and anxiety (HADD and HADA). Another two groups of age-and gender-matched healthy subjects and non-RLS insomnia patients were served as normal and non-RLS insomnia controls.Results There were 162 (3.42%,162/4739) subjects fulfilling all four criteria for RLS; 42 (0.89%,42/4739) subjects were diagnosed as primary RLS and 33 (0.70%,33/4739) as RLS mimics. In primary RLS patients,41(97.6%) were found to be with poor sleep,13 (31.0%) with anxiety,and 4(9.5%) with depression. The scores of PSQI(q=11.69,P=0.000),HADA(q=8.02,P=0.000),and HADD(q=6.60,P=0.000)in primary RLS patients were significantly higher than those in normal controls. The scores of FSS(q=3.74,P=0.001),ESS(q=2.97,P=0.012),and HADD(q=4.15,P=0.000) in primary RLS patients were significantly lower than those in non-RLS insomnia controls. The scores of HADA and HADD were significantly correlated with those of PSQI(r=0.340,P=0.028;r=0.383,P=0.012),FSS(r=0.445,P=0.003;r=0.511,P=0.001),and IRLS(r=0.477,P=0.001;r=0.578,P=0.000). Conclusions RLS should be considered in the patients with any sleep-related complaint or leg discomforts. Primary RLS patients suffer from bad sleep and are more susceptible to anxiety and depression. Secondary RLS and RLS mimics should be excluded before the diagnosis of primary RLS.

  13. Raman lasing in As₂S₃ high-Q whispering gallery mode resonators.

    PubMed

    Vanier, Francis; Rochette, Martin; Godbout, Nicolas; Peter, Yves-Alain

    2013-12-01

    We report the first observation of a nonlinear process in a chalcogenide microresonator. Raman scattering and stimulated Raman scattering leading to laser oscillation is observed in microspheres made of As₂S₃. The coupled pump power threshold is as low as 13 μW using a pump wavelength of 1550 nm. The quality factor of the chalcogenide microresonator is also the highest ever reported with Q>7×10(7).

  14. Application of TQSM polypharmacokinetics and its similarity approach to ascertain Q-marker by analyses of transitivity in vivo of five candidates in Buyanghuanwu injection.

    PubMed

    Zhang, Yu-Tian; Xiao, Mei-Feng; Liao, Qiong; Liu, Wen-Long; Deng, Kai-Wen; Zhou, Yi-Qun; Tang, Yu; He, Fu-Yuan; Yang, Yan-Tao

    2018-03-07

    It is well-known that the public still have been facing on a severe issue about the inconsistency of quality and therapeutic efficacy of traditional medicines. Recently, Professor Chang-Xiao Liu has created a new promising concept for identifying relevant quality-markers (Q-marker) from herbs, their formulas and manufacturing products. Therefore, building up a new approach is necessary for us to bridge over quality to efficacy of pharmaceutical products. In this paper, five candidate Q-markers, astragaloside IV, paeonflorin, amygdalin, tetramethylpyrazine, ferulic acid in Buyanghuanwu injection (BYHWI) had been designed to carry out in rat by using single and polypharmacokinetic models for total quanta to ascertain adequate Q-marker. The Q-marker transitivity in vivo was studied with polypharmacokinetic model and its similarity approach, which were modeled with TQSM principle. The Q-marker was ascertained with transitive similarity and bioavailability in polypharmacokinetics. Their concentrations in plasma sample of white rat were determined by RP-HPLC. Data analyses were used by the DAS software for singles and myself-written-program with EXCEL for multiples. In BYHWI, five candidate Q-marker pharmacokinetic profiles were singly fixed to two compartmental models in rat using classical compartmental analysis, but there were tremendous differences among which the candidate parameters were fluctuated from nearly 3552 folds to equivalency. The theoretical value of TQSM polypharmacokinetic parameters such as AUC T , MRT T , VRT T , CL T , V T over the mixure of five drugs were 110.8 ± 51.91 mg min ml -1 , 176.0 ± 36.5 min, 39,921 ± 4311 min 2 , 0.3116 ± 0.02347 ml min -1  kg -1 , 54.83 ± 7.683 ml kg -1 respectively. The TQSM polypharmacokinetic parameters in astragaloside Ⅳ ordered by AUC T , MRT T , VRT T , CL T , V T were 110.8 ± 51.91 mg min ml -1 , 176.0 ± 36.5 min, 39,921 ± 4311 min 2 , 0.3116 ± 0.02347 ml min -1  kg -1 , 54.83 ± 7.683 ml kg -1 , respectively, which were closed to the theoretical values. TQSM similarity versus astragaloside Ⅳ was 0.9661. The results represented that the optimum Q-marker in BYHWI is astragaloside Ⅳ, whose transitivity in vivo similarity was close to the behavior of polypharmacokinetics with maximum bioavailability to the total quanta. It is feasible for Q-marker in CMMs to screen on the comparison of single pharmacokinetic behavior and bioavailability to the total quanta. Copyright © 2018 Elsevier GmbH. All rights reserved.

  15. Global Maps of Temporal Streamflow Characteristics Based on Observations from Many Small Catchments

    NASA Astrophysics Data System (ADS)

    Beck, H.; van Dijk, A.; de Roo, A.

    2014-12-01

    Streamflow (Q) estimation in ungauged catchments is one of the greatest challenges facing hydrologists. We used observed Q from approximately 7500 small catchments (<10,000 km2) around the globe to train neural network ensembles to estimate temporal Q distribution characteristics from climate and physiographic characteristics of the catchments. In total 17 Q characteristics were selected, including mean annual Q, baseflow index, and a number of flow percentiles. Training coefficients of determination for the estimation of the Q characteristics ranged from 0.56 for the baseflow recession constant to 0.93 for the Q timing. Overall, climate indices dominated among the predictors. Predictors related to soils and geology were the least important, perhaps due to data quality. The trained neural network ensembles were subsequently applied spatially over the ice-free land surface including ungauged regions, resulting in global maps of the Q characteristics (0.125° spatial resolution). These maps possess several unique features: 1) they represent purely observation-driven estimates; 2) are based on an unprecedentedly large set of catchments; and 3) have associated uncertainty estimates. The maps can be used for various hydrological applications, including the diagnosis of macro-scale hydrological models. To demonstrate this, the produced maps were compared to equivalent maps derived from the simulated daily Q of five macro-scale hydrological models, highlighting various opportunities for improvement in model Q behavior. The produced dataset is available for download.

  16. Global maps of streamflow characteristics based on observations from several thousand catchments

    NASA Astrophysics Data System (ADS)

    Beck, Hylke; van Dijk, Albert; de Roo, Ad

    2015-04-01

    Streamflow (Q) estimation in ungauged catchments is one of the greatest challenges facing hydrologists. Observed Q from three to four thousand small-to-medium sized catchments (10-10000 km2) around the globe were used to train neural network ensembles to estimate Q characteristics based on climate and physiographic characteristics of the catchments. In total 17 Q characteristics were selected, including mean annual Q, baseflow index, and a number of flow percentiles. Testing coefficients of determination for the estimation of the Q characteristics ranged from 0.55 for the baseflow recession constant to 0.93 for the Q timing. Overall, climate indices dominated among the predictors. Predictors related to soils and geology were relatively unimportant, perhaps due to their data quality. The trained neural network ensembles were subsequently applied spatially over the entire ice-free land surface, resulting in global maps of the Q characteristics (0.125° resolution). These maps possess several unique features: they represent observation-driven estimates; are based on an unprecedentedly large set of catchments; and have associated uncertainty estimates. The maps can be used for various hydrological applications, including the diagnosis of macro-scale hydrological models. To demonstrate this, the produced maps were compared to equivalent maps derived from the simulated daily Q of four macro-scale hydrological models, highlighting various opportunities for improvement in model Q behavior. The produced dataset is available via http://water.jrc.ec.europa.eu.

  17. Increased pediatric sub-specialization is associated with decreased surgical complication rates for inpatient pediatric urology procedures

    PubMed Central

    Tejwani, R.; Wang, H-H. S.; Young, B. J.; Greene, N. H.; Wolf, S.; Wiener, J. S.; Routh, J. C.

    2016-01-01

    Summary Introduction Increased case volumes and training are associated with better surgical outcomes. However, the impact of pediatric urology sub-specialization on perioperative complication rates is unknown. Objectives To determine the presence and magnitude of difference in rates of common postoperative complications for elective pediatric urology procedures between specialization levels of urologic surgeons. The Nationwide Inpatient Sample (NIS), a nationally representative administrative database, was used. Study Design The NIS (1998–2009) was retrospectively reviewed for pediatric (≤18 years) admissions, using ICD-9-CM codes to identify urologic surgeries and National Surgical Quality Improvement Program (NSQIP) inpatient postoperative complications. Degree of pediatric sub-specialization was calculated using a Pediatric Proportion Index (PPI), defined as the ratio of children to total patients operated on by each provider. The providers were grouped into PPI quartiles: Q1, 0–25% specialization; Q2, 25–50%; Q3, 50–75%; Q4, 75–100%. Weighted multivariate analysis was performed to test for associations between PPI and surgical complications. Results A total of 71,479 weighted inpatient admissions were identified. Patient age decreased with increasing specialization: Q1, 7.9 vs Q2, 4.8 vs Q3, 4.8 vs Q4, 4.6 years, P<0.01). Specialization was not associated with race (P>0.20), gender (P>0.50), or comorbidity scores (P=0.10). Mortality (1.5% vs 0.2% vs 0.3% vs 0.4%, P<0.01) and complication rates (15.5% vs 11.7% vs 9.6% vs 10.9%, P<0.0001) both decreased with increasing specialization. Patients treated by more highly specialized surgeons incurred slightly higher costs (Q2, +4%; Q3, +1%; Q4 + 2%) but experienced shorter length of hospital stay (Q2, –5%; Q3, –10%; Q4, –3%) compared with the least specialized providers. A greater proportion of patients treated by Q1 and Q3 specialized urologists had CCS ≥2 than those seen by Q2 or Q4 urologists (12.5% and 12.2%, respectively vs 8.4% and 10.9%, respectively, P=0.04). Adjusting for confounding effects, increased pediatric specialization was associated with decreased postoperative complications: Q2 OR 0.78, CI 0.58–1.05; Q3 OR 0.60, CI 0.44–0.84; Q4 OR 0.70, CI 0.58–0.84; P<0.01. Discussion Providers with proportionally higher volumes of pediatric patients achieved better postoperative outcomes than their less sub-specialized counterparts. This may have arisen from increased exposure to pediatric anatomy and physiology, and greater familiarity with pediatric techniques. Limitation The NIS admission-based retrospective design did not enable assessment of long-term outcomes, repeated admissions, or to track a particular patient across time. The study was similarly limited in evaluating the effect of pre-surgical referral patterns on patient distributions. Conclusions Increased pediatric sub-specialization among urologists was associated with a decreased risk of mortality and surgical complications in children undergoing inpatient urologic procedures. PMID:27363329

  18. Increased pediatric sub-specialization is associated with decreased surgical complication rates for inpatient pediatric urology procedures.

    PubMed

    Tejwani, R; Wang, H-H S; Young, B J; Greene, N H; Wolf, S; Wiener, J S; Routh, J C

    2016-12-01

    Increased case volumes and training are associated with better surgical outcomes. However, the impact of pediatric urology sub-specialization on perioperative complication rates is unknown. To determine the presence and magnitude of difference in rates of common postoperative complications for elective pediatric urology procedures between specialization levels of urologic surgeons. The Nationwide Inpatient Sample (NIS), a nationally representative administrative database, was used. The NIS (1998-2009) was retrospectively reviewed for pediatric (≤18 years) admissions, using ICD-9-CM codes to identify urologic surgeries and National Surgical Quality Improvement Program (NSQIP) inpatient postoperative complications. Degree of pediatric sub-specialization was calculated using a Pediatric Proportion Index (PPI), defined as the ratio of children to total patients operated on by each provider. The providers were grouped into PPI quartiles: Q1, 0-25% specialization; Q2, 25-50%; Q3, 50-75%; Q4, 75-100%. Weighted multivariate analysis was performed to test for associations between PPI and surgical complications. A total of 71,479 weighted inpatient admissions were identified. Patient age decreased with increasing specialization: Q1, 7.9 vs Q2, 4.8 vs Q3, 4.8 vs Q4, 4.6 years, P < 0.01). Specialization was not associated with race (P > 0.20), gender (P > 0.50), or comorbidity scores (P = 0.10). Mortality (1.5% vs 0.2% vs 0.3% vs 0.4%, P < 0.01) and complication rates (15.5% vs 11.7% vs 9.6% vs 10.9%, P < 0.0001) both decreased with increasing specialization. Patients treated by more highly specialized surgeons incurred slightly higher costs (Q2, +4%; Q3, +1%; Q4 + 2%) but experienced shorter length of hospital stay (Q2, -5%; Q3, -10%; Q4, -3%) compared with the least specialized providers. A greater proportion of patients treated by Q1 and Q3 specialized urologists had CCS ≥2 than those seen by Q2 or Q4 urologists (12.5% and 12.2%, respectively vs 8.4% and 10.9%, respectively, P = 0.04). Adjusting for confounding effects, increased pediatric specialization was associated with decreased postoperative complications: Q2 OR 0.78, CI 0.58-1.05; Q3 OR 0.60, CI 0.44-0.84; Q4 OR 0.70, CI 0.58-0.84; P < 0.01. Providers with proportionally higher volumes of pediatric patients achieved better postoperative outcomes than their less sub-specialized counterparts. This may have arisen from increased exposure to pediatric anatomy and physiology, and greater familiarity with pediatric techniques. The NIS admission-based retrospective design did not enable assessment of long-term outcomes, repeated admissions, or to track a particular patient across time. The study was similarly limited in evaluating the effect of pre-surgical referral patterns on patient distributions. Increased pediatric sub-specialization among urologists was associated with a decreased risk of mortality and surgical complications in children undergoing inpatient urologic procedures. Copyright © 2016 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wally Melnitchouk; John Tjon

    We compute the corrections from two-photon and \\gamma-Z exchange in parity-violating elastic electron--proton scattering, used to extract the strange form factors of the proton. We use a hadronic formalism that successfully reconciled the earlier discrepancy in the proton's electron to magnetic form factor ratio, suitably extended to the weak sector. Implementing realistic electroweak form factors, we find effects of the order 2-3% at Q^2 <~ 0.1 GeV^2, which are largest at backward angles, and have a strong Q^2 dependence at low Q^2. Two-boson contributions to the weak axial current are found to be enhanced at low Q^2 and for forwardmore » angles. We provide corrections at kinematics relevant for recent and upcoming parity-violating experiments.« less

  20. Systematic review and benchmarking of Quality-Adjusted Time Without Symptoms or Toxicity (Q-TWiST) in oncology.

    PubMed

    Solem, Caitlyn T; Kwon, Youngmin; Shah, Ruchit M; Aly, Abdalla; Botteman, Marc F

    2018-02-05

    The Quality-Adjusted Time Without Symptoms or Toxicity (Q-TWiST) has been used to evaluate the clinical benefits and risks of oncology treatments. However, limited information is available to interpret and contextualize Q-TWiST results. Areas covered: A systematic review of Q-TWiST literature was conducted to provide contextualizing benchmarks for future studies. 51 articles with 81 unique Q-TWiST comparisons were identified. The mean (95% CI) and median absolute Q-TWiST gains for treatment versus control arms were 2.78 (1.82-3.73) months and 2.20 months across all cancers, respectively. The mean (median) relative Q-TWiST gains were 7.8% (7.2%) across all cancers. Most (88%) studies reported positive gains. The percentage of studies with relative Q-TWiST gains ≥10% (ie, clinically important difference) and ≥15% (ie, clearly clinically important difference) were 40.0% and 22.7%, respectively. Expert commentary: The relevance of Q-TWiST in assessing net clinical benefits of cancer therapy has not diminished, despite an arguably low number of published studies. The interest in such assessment is highlighted by the recent emergence of oncology value frameworks. The Q-TWiST should be compelling to clinicians as it integrates clinical information (ie, toxicity, relapse/progression, and survival) and patient preferences for each of these states into a single meaningful index.

  1. Validation of eating disorders examination questionnaire in Mexican women.

    PubMed

    Unikel Santoncini, Claudia; Bojorquez Chapela, Ietza; Díaz de León Vázquez, Concepción; Vázquez Velázquez, Verónica; Rivera Márquez, José Alberto; Galván Sánchez, Griselda; Rocha Velis, Ingrid

    2018-02-01

    Efficient assessment of eating disorders (ED) is indispensable for research and clinical practice in Mexico. One of the most commonly used questionnaires, the EDE-Q, has a self-applicable questionnaire format with 28 questions and four subscales drawn from the Eating Disorder Examination (EDE), a semistructured interview developed to evaluate the specific symptomatology of eating disorders. Obtain the factorial structure and construct validity of the EDE-Q questionnaire in Mexican women. The language in the EDE-Q was adapted. It was applied to university students (N = 330) and a sample of patients with ED (N = 165) from two ED outpatient treatment services. The anthropometric data of the participants was obtained. Internal consistency was explored using the Cronbach's Alpha coefficient and a confirmatory factor analysis was conducted by group. Cronbach's alpha was 0.9 for the full scale in all groups, while the reliability of each of the subscales fluctuated between 0.8 and 0.9. Confirmatory factor analysis showed that the fit of the seven-item model in three factors was better than that of the original 22-item one and that of the eight-item model for one factor. This study provides information supporting the seven-item and three-factor version, rather than the original or eight-item versions of the EDE-Q. In the future, the adapted version of the EDE-Q will make it possible to draw comparisons between Mexican samples in other socio-cultural contexts. Future research is required to continue refining the instruments to achieve more representative results from the general ED population. © 2018 Wiley Periodicals, Inc.

  2. One-year outcomes of the da Vinci Study of VEGF Trap-Eye in eyes with diabetic macular edema.

    PubMed

    Do, Diana V; Nguyen, Quan Dong; Boyer, David; Schmidt-Erfurth, Ursula; Brown, David M; Vitti, Robert; Berliner, Alyson J; Gao, Bo; Zeitz, Oliver; Ruckert, Rene; Schmelter, Thomas; Sandbrink, Rupert; Heier, Jeff S

    2012-08-01

    To compare different doses and dosing regimens of Vascular Endothelial Growth Factor (VEGF) Trap-Eye with laser photocoagulation in eyes with diabetic macular edema (DME). Randomized, double-masked, multicenter, phase 2 clinical trial. Diabetic patients (n = 221) with center-involved DME. Participants were assigned randomly to 1 of 5 treatment regimens: VEGF Trap-Eye 0.5 mg every 4 weeks (0.5q4); 2 mg every 4 weeks (2q4); 2 mg every 8 weeks after 3 initial monthly doses (2q8); or 2 mg dosing as needed after 3 initial monthly doses (2PRN), or macular laser photocoagulation. The change in best-corrected visual acuity (BCVA) at 24 weeks (the primary end point) and at 52 weeks, proportion of eyes that gained 15 letters or more in Early Treatment of Diabetic Retinopathy Study (ETDRS) BCVA, and mean changes in central retinal thickness (CRT) from baseline. As previously reported, mean improvements in BCVA in the VEGF Trap-Eye groups at week 24 were 8.6, 11.4, 8.5, and 10.3 letters for 0.5q4, 2q4, 2q8, and 2PRN regimens, respectively, versus 2.5 letters for the laser group (P ≤ 0.0085 versus laser). Mean improvements in BCVA in the VEGF Trap-Eye groups at week 52 were 11.0, 13.1, 9.7, and 12.0 letters for 0.5q4, 2q4, 2q8, and 2PRN regimens, respectively, versus -1.3 letters for the laser group (P ≤ 0.0001 versus laser). Proportions of eyes with gains in BCVA of 15 or more ETDRS letters at week 52 in the VEGF Trap-Eye groups were 40.9%, 45.5%, 23.8%, and 42.2% versus 11.4% for laser (P = 0.0031, P = 0.0007, P = 0.1608, and P = 0.0016, respectively, versus laser). Mean reductions in CRT in the VEGF Trap-Eye groups at week 52 were -165.4 μm, -227.4 μm, -187.8 μm, and -180.3 μm versus -58.4 μm for laser (P < 0.0001 versus laser). Vascular Endothelial Growth Factor Trap-Eye generally was well tolerated. The most frequent ocular adverse events with VEGF Trap-Eye were conjunctival hemorrhage, eye pain, ocular hyperemia, and increased intraocular pressure, whereas common systemic adverse events included hypertension, nausea, and congestive heart failure. Significant gains in BCVA from baseline achieved at week 24 were maintained or improved at week 52 in all VEGF Trap-Eye groups. Vascular Endothelial Growth Factor Trap-Eye warrants further investigation for the treatment of DME. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  3. DNA copy number gains at loci of growth factors and their receptors in salivary gland adenoid cystic carcinoma.

    PubMed

    Vékony, Hedy; Ylstra, Bauke; Wilting, Saskia M; Meijer, Gerrit A; van de Wiel, Mark A; Leemans, C René; van der Waal, Isaäc; Bloemena, Elisabeth

    2007-06-01

    Adenoid cystic carcinoma (ACC) is a malignant salivary gland tumor with a high mortality rate due to late, distant metastases. This study aimed at unraveling common genetic abnormalities associated with ACC. Additionally, chromosomal changes were correlated with patient characteristics and survival. Microarray-based comparative genomic hybridization was done to a series of 18 paraffin-embedded primary ACCs using a genome-wide scanning BAC array. A total of 238 aberrations were detected, representing more gains than losses (205 versus 33, respectively). Most frequent gains (>60%) were observed at 9q33.3-q34.3, 11q13.3, 11q23.3, 19p13.3-p13.11, 19q12-q13.43, 21q22.3, and 22q13.33. These loci harbor numerous growth factor [fibroblast growth factor (FGF) and platelet-derived growth factor (PDGF)] and growth factors receptor (FGFR3 and PDGFRbeta) genes. Gains at the FGF(R) regions occurred significantly more frequently in the recurred/metastasized ACCs compared with indolent ACCs. Furthermore, patients with 17 or more chromosomal aberrations had a significantly less favorable outcome than patients with fewer chromosomal aberrations (log-rank = 5.2; P = 0.02). Frequent DNA copy number gains at loci of growth factors and their receptors suggest their involvement in ACC initiation and progression. Additionally, the presence of FGFR3 and PDGFRbeta in increased chromosomal regions suggests a possible role for autocrine stimulation in ACC tumorigenesis.

  4. PON1Q192R genetic polymorphism modifies organophosphorous pesticide effects on semen quality and DNA integrity in agricultural workers from southern Mexico

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perez-Herrera, N.; Polanco-Minaya, H.; Salazar-Arredondo, E.

    Pesticide exposure, including organophosphorous (OP) insecticides, has been associated with poor semen quality, and paraoxonase (PON1), an enzyme involved in OP deactivation, may have a role on their susceptibility, due to PON1 polymorphisms. Our objective was to evaluate the role of PON1Q192R polymorphism on the susceptibility to OP toxicity on semen quality and DNA integrity in agricultural workers. A cross-sectional study was conducted in farmers with Mayan ascendancy from southeastern Mexico chronically exposed to pesticides; mostly OP. Fifty four agricultural workers (18-55 years old) were included, who provided semen and blood samples. Semen quality was evaluated according to WHO, spermmore » DNA damage by in situ-nick translation (NT-positive cells), PON1Q192R polymorphism by real-time PCR and serum PON1 activity by using phenylacetate and paraoxon. Two OP exposure indexes were created: at the month of sampling and during 3 months before sampling, representing the exposure to spermatids-spermatozoa and to cells at one spermatogenic cycle, respectively. PON1 192R and 192Q allele frequencies were 0.54 and 0.46, respectively. Significant associations were found between OP exposure at the month of sampling and NT-positive cells and sperm viability in homozygote 192RR subjects, and dose-effect relationships were observed between OP exposure during 3 months before sampling and sperm quality parameters and NT-positive cells in homozygote 192RR farmers. This suggests that cells at all stages of spermatogenesis are target of OP, and that there exists an interaction between OP exposure and PON1Q192R polymorphism on these effects; farmers featuring the 192RR genotype were more susceptible to develop reproductive toxic effects by OP exposure.« less

  5. Androgen receptor polyglutamine expansion drives age-dependent quality control defects and muscle dysfunction.

    PubMed

    Nath, Samir R; Yu, Zhigang; Gipson, Theresa A; Marsh, Gregory B; Yoshidome, Eriko; Robins, Diane M; Todi, Sokol V; Housman, David E; Lieberman, Andrew P

    2018-05-29

    Skeletal muscle has emerged as a critical, disease-relevant target tissue in spinal and bulbar muscular atrophy, a degenerative disorder of the neuromuscular system caused by a CAG/polyglutamine (polyQ) expansion in the androgen receptor (AR) gene. Here, we used RNA-Seq to identify pathways that are disrupted in diseased muscle using AR113Q knock-in mice. This analysis unexpectedly identified significantly diminished expression of numerous ubiquitin-proteasome pathway genes in AR113Q muscle, encoding approximately 30% of proteasome subunits and 20% of E2 ubiquitin conjugases. These changes were age-, hormone- and glutamine length-dependent and arose due to a toxic gain-of-function conferred by the mutation. Moreover, altered gene expression was associated with decreased level of the proteasome transcription factor NRF1 and its activator DDI2 and resulted in diminished proteasome activity. Ubiquitinated ADRM1 was detected in AR113Q muscle, indicating the occurrence of stalled proteasomes in mutant mice. Finally, diminished expression of Drosophila orthologues of NRF1 or ADRM1 promoted the accumulation of polyQ AR protein and increased toxicity. Collectively, these data indicate that AR113Q muscle develops progressive proteasome dysfunction that leads to the impairment of quality control and the accumulation of polyQ AR protein, key features that contribute to the age-dependent onset and progression of this disorder.

  6. Quasicrystals and Quantum Computing

    NASA Astrophysics Data System (ADS)

    Berezin, Alexander A.

    1997-03-01

    In Quantum (Q) Computing qubits form Q-superpositions for macroscopic times. One scheme for ultra-fast (Q) computing can be based on quasicrystals. Ultrafast processing in Q-coherent structures (and the very existence of durable Q-superpositions) may be 'consequence' of presence of entire manifold of integer arithmetic (A0, aleph-naught of Georg Cantor) at any 4-point of space-time, furthermore, at any point of any multidimensional phase space of (any) N-particle Q-system. The latter, apart from quasicrystals, can include dispersed and/or diluted systems (Berezin, 1994). In such systems such alleged centrepieces of Q-Computing as ability for fast factorization of long integers can be processed by sheer virtue of the fact that entire infinite pattern of prime numbers is instantaneously available as 'free lunch' at any instant/point. Infinitely rich pattern of A0 (including pattern of primes and almost primes) acts as 'independent' physical effect which directly generates Q-dynamics (and physical world) 'out of nothing'. Thus Q-nonlocality can be ultimately based on instantaneous interconnectedness through ever- the-same structure of A0 ('Platonic field' of integers).

  7. Serum uric acid level as a cardio-cerebrovascular event risk factor in middle-aged and non-obese Chinese men.

    PubMed

    Li, Zhi-Jun; Yi, Chen-Ju; Li, Jing; Tang, Na

    2017-04-11

    The role of uric acid as a risk factor for cardio-cerebrovascular diseases is controversial. In this study, we aimed to investigate the relationship between serum uric acid level and the risk of cardio-cerebrovascular events in middle-aged and non-obese Chinese men. We included 3152 participants from the health examination center of Tongji Hospital from June 2007 to June 2010. Clinical examination and medical records were collected at the annual health examination. The hazard ratios (HRs) of uric acid for cardio-cerebrovascular events were calculated by Cox proportional hazards models. Generalized additive model and threshold effect analysis were used to explore the non-linear relationship between serum uric acid level and the incidence of cardio-cerebrovascular event. The mean follow-up time was 52 months. When the participants were classified into four groups by the serum acid quarter (Q1-Q4), the HRs (95% CI) of Q2-Q4 for cardio-cerebrovascular events were 1.26 (0.83, 1.92), 1.97 (1.33, 2.91) and 2.05 (1.40, 3.01), respectively, compared with the reference (Q1). The actual incidence and conditional incidence of cardio-cerebrovascular events in the high serum acid group were higher than those in the low serum acid group, which were stratified by the turning point (sUA = 372 μmol/L). We also showed a strong prognostic accuracy of the multiple variable-based score in 3 years and 5 years, with area under the receiver operating characteristic (ROC) curve of 0.790 (0.756-0.823) and 0.777 (0.749-0.804), respectively. Serum uric acid level is a strong risk factor for cardio-cerebrovascular events.

  8. Clinical effectiveness and cost-effectiveness of quadrivalent human papillomavirus vaccination in HIV-negative men who have sex with men to prevent recurrent high-grade anal intraepithelial neoplasia.

    PubMed

    Deshmukh, Ashish A; Chiao, Elizabeth Y; Das, Prajnan; Cantor, Scott B

    2014-12-05

    We examined the long-term clinical and economic benefits of quadrivalent human papillomavirus (qHPV) vaccine as a secondary/adjunct prevention strategy in the prevention of recurrent high-grade intraepithelial neoplasia (HGAIN) in HIV-negative men who have sex with men (MSM) and are 27 years or older. We constructed a Markov model to evaluate the clinical effectiveness and cost-effectiveness of two strategies: (1) no qHPV vaccine after treatment for HGAIN versus (2) qHPV vaccine after treatment for HGAIN. Model parameters, including natural history of anal cancer, vaccine efficacy measured in terms of hazard ratio (HR) (decrease in the risk of recurrent HGAIN), HGAIN treatment efficacy, utilities, and costs, were obtained from the literature. The outcomes were measured in terms of lifetime risk of anal cancer, lifetime cost, quality-adjusted life years, and incremental cost-effectiveness ratios (ICERs). Sensitivity analysis was conducted on all model parameters. We found that vaccinating HIV-negative MSM reduced the lifetime risk of anal cancer by 60.77% at an ICER of US$87,240 per quality-adjusted life-year. The results were highly sensitive to vaccine efficacy, transition of HGAIN to anal cancer, cost of treatment for HGAIN, vaccine degree of protection over time, and the vaccine duration of protection and less sensitive to HPV clearance, cost of qHPV vaccine, and the transitions from normal to low-grade anal intraepithelial neoplasia (LGAIN) and normal to HGAIN. With an HR of 0.3, the ICER was well below a $50,000 willingness-to-pay threshold; with an HR of 0.5, the ICER was still below a threshold of $100,000. The most critical disease-related factor influencing the cost-effectiveness was the progression of HGAIN to anal cancer. At an annual transition probability below 0.001, the ICER was below $50,000. Vaccinating HIV-negative MSM treated for HGAIN decreases the lifetime risk of anal cancer and is likely to be a cost-effective intervention. Published by Elsevier Ltd.

  9. First measurement of proton's charge form factor at very low Q 2 with initial state radiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mihovilovič, M.; Weber, A. B.; Achenbach, P.

    Here we report on a new experimental method based on initial-state radiation (ISR) in e–pscattering, which exploits the radiative tail of the elastic peak to study the properties of electromagnetic processes and to extract the proton charge form factor (Gmore » $$p\\atop{E}$$) at extremely small Q 2. The ISR technique was implemented in an experiment at the three-spectrometer facility of the Mainz Microtron (MAMI). This led to a precise validation of radiative corrections far away from elastic line and provided first measurements of G$$p\\atop{E}$$ for 0.001 ≤Q 2≤0.004 (GeV/c) 2.« less

  10. First measurement of proton's charge form factor at very low Q 2 with initial state radiation

    DOE PAGES

    Mihovilovič, M.; Weber, A. B.; Achenbach, P.; ...

    2017-05-15

    Here we report on a new experimental method based on initial-state radiation (ISR) in e–pscattering, which exploits the radiative tail of the elastic peak to study the properties of electromagnetic processes and to extract the proton charge form factor (Gmore » $$p\\atop{E}$$) at extremely small Q 2. The ISR technique was implemented in an experiment at the three-spectrometer facility of the Mainz Microtron (MAMI). This led to a precise validation of radiative corrections far away from elastic line and provided first measurements of G$$p\\atop{E}$$ for 0.001 ≤Q 2≤0.004 (GeV/c) 2.« less

  11. An improved peak frequency shift method for Q estimation based on generalized seismic wavelet function

    NASA Astrophysics Data System (ADS)

    Wang, Qian; Gao, Jinghuai

    2018-02-01

    As a powerful tool for hydrocarbon detection and reservoir characterization, the quality factor, Q, provides useful information in seismic data processing and interpretation. In this paper, we propose a novel method for Q estimation. The generalized seismic wavelet (GSW) function was introduced to fit the amplitude spectrum of seismic waveforms with two parameters: fractional value and reference frequency. Then we derive an analytical relation between the GSW function and the Q factor of the medium. When a seismic wave propagates through a viscoelastic medium, the GSW function can be employed to fit the amplitude spectrum of the source and attenuated wavelets, then the fractional values and reference frequencies can be evaluated numerically from the discrete Fourier spectrum. After calculating the peak frequency based on the obtained fractional value and reference frequency, the relationship between the GSW function and the Q factor can be built by the conventional peak frequency shift method. Synthetic tests indicate that our method can achieve higher accuracy and be more robust to random noise compared with existing methods. Furthermore, the proposed method is applicable to different types of source wavelet. Field data application also demonstrates the effectiveness of our method in seismic attenuation and the potential in the reservoir characteristic.

  12. Poly (N-vinyl Carbazole) - Polypyrrole/graphene oxide nanocomposite material on tapered fiber for Q-switched pulse generation

    NASA Astrophysics Data System (ADS)

    Ahmad, H.; Faruki, M. J.; Jasim, A. A.; Ooi, S. I.; Thambiratnam, K.

    2018-02-01

    A passively Q-switched fiber laser using a Saturable Absorber (SA) fabricated from a new Poly (N-vinyl Carbazole) - Polypyrrole/Graphene Oxide (PNVC-PPy/GO) nanocomposite material deposited on a tapered fiber is proposed and demonstrated. The PNVC-PPy/GO composition is deposited along a 3 mm length of the 6.5 cm tapered fiber which has a tapered waist of 8 μm. Q-switched pulses are obtained with repetition rates of 25.15-42.7 kHz and pulse widths of 5.74-2.48 μs over a pump power range of 12.8-40.0 mW. A maximum average power of 0.19 mW and pulse energy of 4.43 nJ are also observed. The proposed Q-switched maintains advantages of a simple design and low fabrication cost while at the same time generating high quality Q-switched pulses.

  13. Measurement of the B0 -> pilnu form-factor shape and branching fraction, and determination of |Vub| with a loose neutrino reconstruction technique; Mesure du rapport d'embranchement et du facteur deforme de la desintegration B0 to pilnu, et determination de |Vub| avec unetechnique de reconstruction relachee du neutrino (in French)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cote, David

    2007-04-01

    The authors report the results of a study of the exclusive charmless semileptonic decay, B 0 → π -ℓ +v, undertaken with approximately 227 million Bmore » $$\\bar{B}$$ pairs collected at the Y(4S) resonance with the BABAR detector. The analysis uses events in which the signal B decays are reconstructed with an innovative loose neutrino reconstruction technique. They obtain partial branching fractions in 12 bins of q 2, the momentum transfer squared, from which they extract the f +(q 2) form-factor shape and the total branching fraction β(B 0 → π -ℓ +v) = (1.46 ± 0.07 stat ± 0.08 syst) x 10 -4. Based on a recent unquenched lattice QCD calculation of the form factor in the range q 2 > 16 GeV 2/c 4, they find the magnitude of the CKM matrix element |V ub| to be (4.1 ± 0.2 stat ± 0.2 syst$$+0.6\\atop{-0.4}$$FF}) x 10 -3, where the last uncertainty is due to the normalization of the form factor.« less

  14. A novel approach to the analysis of squeezed-film air damping in microelectromechanical systems

    NASA Astrophysics Data System (ADS)

    Yang, Weilin; Li, Hongxia; Chatterjee, Aveek N.; Elfadel, Ibrahim (Abe M.; Ender Ocak, Ilker; Zhang, TieJun

    2017-01-01

    Squeezed-film damping (SFD) is a phenomenon that significantly affects the performance of micro-electro-mechanical systems (MEMS). The total damping force in MEMS mainly include the viscous damping force and elastic damping force. Quality factor (Q factor) is usually used to evaluate the damping in MEMS. In this work, we measure the Q factor of a resonator through experiments in a wide range of pressure levels. In fact, experimental characterizations of MEMS have some limitations because it is difficult to conduct experiments at very high vacuum and also hard to differentiate the damping mechanisms from the overall Q factor measurements. On the other hand, classical theoretical analysis of SFD is restricted to strong assumptions and simple geometries. In this paper, a novel numerical approach, which is based on lattice Boltzmann simulations, is proposed to investigate SFD in MEMS. Our method considers the dynamics of squeezed air flow as well as fluid-solid interactions in MEMS. It is demonstrated that Q factor can be directly predicted by numerical simulation, and our simulation results agree well with experimental data. Factors that influence SFD, such as pressure, oscillating amplitude, and driving frequency, are investigated separately. Furthermore, viscous damping and elastic damping forces are quantitatively compared based on comprehensive simulation. The proposed numerical approach as well as experimental characterization enables us to reveal the insightful physics of squeezed-film air damping in MEMS.

  15. Elastic and anelastic structure of the lowermost mantle beneath the Western Pacific from waveform inversion

    NASA Astrophysics Data System (ADS)

    Konishi, Kensuke; Fuji, Nobuaki; Deschamps, Frédéric

    2017-03-01

    We investigate the elastic and anelastic structure of the lowermost mantle at the western edge of the Pacific large low shear velocity province (LLSVP) by inverting a collection of S and ScS waveforms. The transverse component data were obtained from F-net for 31 deep earthquakes beneath Tonga and Fiji, filtered between 12.5 and 200 s. We observe a regional variation of S and ScS arrival times and amplitude ratios, according to which we divide our region of interest into three subregions. For each of these subregions, we then perform 1-D (depth-dependent) waveform inversions simultaneously for radial profiles of shear wave velocity (VS) and seismic quality factor (Q). Models for all three subregions show low VS and low Q structures from 2000 km depth down to the core-mantle boundary. We further find that VS and Q in the central subregion, sampling the Caroline plume, are substantially lower than in the surrounding regions, whatever the depth. In the central subregion, VS-anomalies with respect to PREM (dVS) and Q are about -2.5 per cent and 216 at a depth of 2850 km, and -0.6 per cent and 263 at a depth of 2000 km. By contrast, in the two other regions, dVS and Q are -2.2 per cent and 261 at a depth of 2850 km, and -0.3 per cent and 291 at a depth of 2000 km. At depths greater than ∼2500 km, these differences may indicate lateral variations in temperature of ∼100 K within the Pacific LLSVP. At shallower depths, they may be due to the temperature difference between the Caroline plume and its surroundings, and possibly to a small fraction of iron-rich material entrained by the plume.

  16. Infrared light detection using a whispering-gallery-mode optical microcavity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhu, Jiangang, E-mail: jzhu@seas.wustl.edu, E-mail: ozdemir@seas.wustl.edu, E-mail: yang@seas.wustl.edu; Ozdemir, Sahin Kaya, E-mail: jzhu@seas.wustl.edu, E-mail: ozdemir@seas.wustl.edu, E-mail: yang@seas.wustl.edu; Yang, Lan, E-mail: jzhu@seas.wustl.edu, E-mail: ozdemir@seas.wustl.edu, E-mail: yang@seas.wustl.edu

    2014-04-28

    We demonstrate a thermal infrared (IR) detector based on an ultra-high-quality-factor (Q) whispering-gallery-mode (WGM) microtoroidal silica resonator and investigate its performance to detect IR radiation at 10 μm wavelength. The bandwidth and the sensitivity of the detector are dependent on the power of a probe laser and the detuning between the probe laser and the resonance frequency of the resonator. The microtoroid IR sensor achieved a noise-equivalent-power (NEP) of 7.46 nW, corresponding to an IR intensity of 0.095 mW/cm{sup 2}.

  17. Excitation of hypersonic acoustic waves in diamond-based piezoelectric layered structure on the microwave frequencies up to 20GHz.

    PubMed

    Sorokin, B P; Kvashnin, G M; Novoselov, A S; Bormashov, V S; Golovanov, A V; Burkov, S I; Blank, V D

    2017-07-01

    First ultrahigh frequency (UHF) investigation of quality factor Q for the piezoelectric layered structure «Al/(001)AlN/Mo/(100) diamond» has been executed in a broad frequency band from 1 up to 20GHz. The record-breaking Q·f quality parameter up to 2.7·10 14 Hz has been obtained close to 20GHz. Frequency dependence of the form factor m correlated with quality factor has been analyzed by means of computer simulation, and non-monotonic frequency dependence can be explained by proper features of thin-film piezoelectric transducer (TFPT). Excluding the minimal Q magnitudes measured at the frequency points associated with minimal TFPT effectiveness, one can prove a rule of Qf∼f observed for diamond on the frequencies above 1GHz and defined by Landau-Rumer's acoustic attenuation mechanism. Synthetic IIa-type diamond single crystal as a substrate material for High-overtone Bulk Acoustic Resonator (HBAR) possesses some excellent acoustic properties in a wide microwave band and can be successfully applied for design of acoustoelectronic devices, especially the ones operating at a far UHF band. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. High-Q lattice mode matched structural resonances in terahertz metasurfaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Ningning; Zhang, Weili, E-mail: weili.zhang@okstate.edu; Singh, Ranjan, E-mail: ranjans@ntu.edu.sg

    2016-07-11

    The quality (Q) factor of metamaterial resonances is limited by the radiative and non-radiative losses. At terahertz frequencies, the dominant loss channel is radiative in nature since the non-radiative losses are low due to high conductivity of metals. Radiative losses could be suppressed by engineering the meta-atom structure. However, such suppression usually occurs at the fundamental resonance mode which is typically a closed mode resonance such as an inductive-capacitive resonance or a Fano resonance. Here, we report an order of magnitude enhancement in Q factor of all the structural eigenresonances of a split-ring resonator fueled by the lattice mode matching.more » We match the fundamental order diffractive mode to each of the odd and even eigenresonances, thus leading to a tremendous line-narrowing of all the resonances. Such precise tailoring and control of the structural resonances in a metasurface lattice could have potential applications in low-loss devices, sensing, and design of high-Q metamaterial cavities.« less

  19. MitoQ modulates oxidative stress and decreases inflammation following hemorrhage.

    PubMed

    Powell, Rebecca D; Swet, Jacob H; Kennedy, Kenneth L; Huynh, Toan T; Murphy, Michael P; Mckillop, Iain H; Evans, Susan L

    2015-03-01

    Oxidative stress associated with hemorrhagic shock and reperfusion (HSR) results in the production of superoxide radicals and other reactive oxygen species, leading to cell damage and multiple-organ dysfunction. We sought to determine if MitoQ, a mitochondria-targeted antioxidant, reduces morbidity in a rat model of HSR by limiting oxidative stress. HSR was achieved in male rats by arterial blood withdrawal to a mean arterial pressure of 25 ± 2 mm Hg for 1 hour before resuscitation. MitoQ (5 mg/kg), TPP (triphenylphosphonium, 5 mg/kg) or saline (0.9% vol./vol.) was administered intravenously 30 minutes before resuscitation, followed by an intraperitoneal administration (MitoQ, 20 mg/kg) immediately after resuscitation (n = 5 per group). Morbidity was assessed based on cumulative markers of animal distress (0-10 scale). Rats were sacrificed 2 hours after procedure completion, and liver tissue was collected and processed for histology or assayed for lipid peroxidation (thiobarbituric acid reactive substance [TBARS]) or endogenous antioxidant (catalase, glutathione peroxidase [GPx], and superoxide dismutase) activity. HSR significantly increased morbidity as well as TBARS and catalase activities versus sham. Conversely, no difference in GPx or superoxide dismutase activity was measured between sham, HSR, and TPP, MitoQ administration reduced morbidity versus HSR (5.8 ± 0.3 vs. 7.6 ± 0.3; p < 0.05), while TPP administration significantly reduced hepatic necrosis versus both HSR and HSR-MitoQ (1.2 ± 0.1 vs. 2.0 ± 0.2 vs. 1.9 ± 0.2; p < 0.05, n = 5). Analysis of oxidative stress demonstrated increased TBARS and GPx in HSR-MitoQ versus sham (12.0 ± 1.1 μM vs. 6.2 ± 0.5 μM and 37.9 ± 3.0 μmol/min/mL vs. 22.9 ± 2.7 μmol/min/mL, TBARS and GPx, respectively, n = 5; p < 0.05). Conversely, catalase activity in HSR-MitoQ was reduced versus HSR (1.96 ± 1.17 mol/min/mL vs. 2.58 ± 1.81 mol/min/mL; n = 5; p < 0.05). Finally, MitoQ treatment decreased tumor necrosis factor α (0.66 ± 0.07 pg/mL vs. 0.92 ± 0.08 pg/mL) and interleukin 6 (7.3 ± 0.8 pg/mL vs. 11 ± 0.9 pg/mL) versus HSR as did TPP alone (0.58 ± 0.05 pg/mL vs. 0.92 ± 0.08 pg/mL; 6.7 ± 0.6 pg/mL vs. 11 ± 0.9 pg/mL; n = 5; p < 0.05). Our data demonstrate that MitoQ treatment following hemorrhage significantly limits morbidity and decreases hepatic tumor necrosis factor α and interleukin 6. In addition, MitoQ differentially modulates oxidative stress and hepatic antioxidant activity.

  20. Coenzyme Q(1) as a probe for mitochondrial complex I activity in the intact perfused hyperoxia-exposed wild-type and Nqo1-null mouse lung.

    PubMed

    Bongard, Robert D; Myers, Charles R; Lindemer, Brian J; Baumgardt, Shelley; Gonzalez, Frank J; Merker, Marilyn P

    2012-05-01

    Previous studies showed that coenzyme Q(1) (CoQ(1)) reduction on passage through the rat pulmonary circulation was catalyzed by NAD(P)H:quinone oxidoreductase 1 (NQO1) and mitochondrial complex I, but that NQO1 genotype was not a factor in CoQ(1) reduction on passage through the mouse lung. The aim of the present study was to evaluate the complex I contribution to CoQ(1) reduction in the isolated perfused wild-type (NQO1(+/+)) and Nqo1-null (NQO1(-)/(-)) mouse lung. CoQ(1) reduction was measured as the steady-state pulmonary venous CoQ(1) hydroquinone (CoQ(1)H(2)) efflux rate during infusion of CoQ(1) into the pulmonary arterial inflow. CoQ(1)H(2) efflux rates during infusion of 50 μM CoQ(1) were not significantly different for NQO1(+/+) and NQO1(-/-) lungs (0.80 ± 0.03 and 0.68 ± 0.07 μmol·min(-1)·g lung dry wt(-1), respectively, P > 0.05). The mitochondrial complex I inhibitor rotenone depressed CoQ(1)H(2) efflux rates for both genotypes (0.19 ± 0.08 and 0.08 ± 0.04 μmol·min(-1)·g lung dry wt(-1) for NQO1(+/+) and NQO1(-/-), respectively, P < 0.05). Exposure of mice to 100% O(2) for 48 h also depressed CoQ(1)H(2) efflux rates in NQO1(+/+) and NQO1(-/-) lungs (0.43 ± 0.03 and 0.11 ± 0.04 μmol·min(-1)·g lung dry wt(-1), respectively, P < 0.05 by ANOVA). The impact of rotenone or hyperoxia on CoQ(1) redox metabolism could not be attributed to effects on lung wet-to-dry weight ratios, perfusion pressures, perfused surface areas, or total venous effluent CoQ(1) recoveries, the latter measured by spectrophotometry or mass spectrometry. Complex I activity in mitochondria-enriched lung fractions was depressed in hyperoxia-exposed lungs for both genotypes. This study provides new evidence for the potential utility of CoQ(1) as a nondestructive indicator of the impact of pharmacological or pathological exposures on complex I activity in the intact perfused mouse lung.

  1. Method for determining formation quality factor from seismic data

    DOEpatents

    Taner, M. Turhan; Treitel, Sven

    2005-08-16

    A method is disclosed for calculating the quality factor Q from a seismic data trace. The method includes calculating a first and a second minimum phase inverse wavelet at a first and a second time interval along the seismic data trace, synthetically dividing the first wavelet by the second wavelet, Fourier transforming the result of the synthetic division, calculating the logarithm of this quotient of Fourier transforms and determining the slope of a best fit line to the logarithm of the quotient.

  2. Effect of BST film thickness on the performance of tunable interdigital capacitors grown by MBE

    NASA Astrophysics Data System (ADS)

    Meyers, Cedric J. G.; Freeze, Christopher R.; Stemmer, Susanne; York, Robert A.

    2017-12-01

    Voltage-tunable, interdigital capacitors (IDCs) were fabricated on Ba0.29Sr0.71TiO3 grown by hybrid molecular beam epitaxy (MBE). In this growth technique, we utilize the metal-organic precursor titanium tetraisopropoxide rather than solid-source Ti as with conventional MBE. Two samples of varying BaxSr(1-x)TiO3 (BST) thicknesses were fabricated and analyzed. High-quality, epitaxial Pt electrodes were deposited by sputtering from a high-purity Pt target at 825 °C. The Pt electrodes were patterned and etched by argon ion milling, passivated with reactively sputtered SiO2, and then metallized with lift-off Ti/Au. The fabricated devices consisted of two-port IDCs embedded in ground-signal-ground, coplanar waveguide (CPW) transmission lines to enable radio-frequency (RF) probing. The sample included open and thru de-embedding structures to remove pad and CPW parasitic impedances. Two-port RF scattering (S) parameters were measured from 100 MHz to 40 GHz while DC bias was stepped from 0 V to 100 V. The IDCs exhibit a high zero-bias radio-frequency (RF) quality factor (Q) approaching 200 at 1 GHz and better than 2.3:1 capacitance tuning for the 300-nm-thick sample. Differences in the Q(V) and C(V) response with varying thicknesses indicate that unknown higher order material phenomena are contributing to the loss and tuning characteristics of the material.

  3. Mitochondrial Quality Control via the PGC1α-TFEB Signaling Pathway Is Compromised by Parkin Q311X Mutation But Independently Restored by Rapamycin.

    PubMed

    Siddiqui, Almas; Bhaumik, Dipa; Chinta, Shankar J; Rane, Anand; Rajagopalan, Subramanian; Lieu, Christopher A; Lithgow, Gordon J; Andersen, Julie K

    2015-09-16

    Following its activation by PINK1, parkin is recruited to depolarized mitochondria where it ubiquitinates outer mitochondrial membrane proteins, initiating lysosomal-mediated degradation of these organelles. Mutations in the gene encoding parkin, PARK2, result in both familial and sporadic forms of Parkinson's disease (PD) in conjunction with reductions in removal of damaged mitochondria. In contrast to what has been reported for other PARK2 mutations, expression of the Q311X mutation in vivo in mice appears to involve a downstream step in the autophagic pathway at the level of lysosomal function. This coincides with increased PARIS expression and reduced expression of a reciprocal signaling pathway involving the master mitochondrial regulator peroxisome proliferator-activated receptor-gamma coactivator (PGC1α) and the lysosomal regulator transcription factor EB (TFEB). Treatment with rapamycin was found to independently restore PGC1α-TFEB signaling in a manner not requiring parkin activity and to abrogate impairment of mitochondrial quality control and neurodegenerative features associated with this in vivo model. Losses in PGC1α-TFEB signaling in cultured rat DAergic cells expressing the Q311X mutation associated with reduced mitochondrial function and cell viability were found to be PARIS-dependent and to be independently restored by rapamycin in a manner requiring TFEB. Studies in human iPSC-derived neurons demonstrate that TFEB induction can restore mitochondrial function and cell viability in a mitochondrially compromised human cell model. Based on these data, we propose that the parkin Q311X mutation impacts on mitochondrial quality control via PARIS-mediated regulation of PGC1α-TFEB signaling and that this can be independently restored via upregulation of TFEB function. Mutations in PARK2 are generally associated with loss in ability to interact with PINK1, impacting on autophagic initiation. Our data suggest that, in the case of at least one parkin mutation, Q311X, detrimental effects are due to inhibition at the level of downstream lysosomal function. Mechanistically, this involves elevations in PARIS protein levels and subsequent effects on PGC1α-TFEB signaling that normally regulates mitochondrial quality control. Treatment with rapamycin independently restores PGC1α-TFEB signaling in a manner not requiring parkin activity and abrogates subsequent mitochondrial impairment and neuronal cell loss. Taken in total, our data suggest that the parkin Q311X mutation impacts on mitochondrial quality control via PARIS-mediated regulation of PGC1α-TFEB signaling and that this can be independently restored via rapamycin. Copyright © 2015 the authors 0270-6474/15/3512833-12$15.00/0.

  4. Monetary Value of Diet Is Associated with Dietary Quality and Nutrient Adequacy among Urban Adults, Differentially by Sex, Race and Poverty Status.

    PubMed

    Beydoun, May A; Fanelli-Kuczmarski, Marie T; Allen, Allyssa; Beydoun, Hind A; Popkin, Barry M; Evans, Michele K; Zonderman, Alan B

    2015-01-01

    The association between monetary value of the diet (MVD, $/day) with dietary quality was examined using a large sample of urban US adults, differentially by socio-demographic factors. This was a cross-sectional study of 2,111 participants, aged 30-64y, using data from the Healthy Aging in Neighborhoods of Diversity across the Life Span Study. Dietary quality indices included Healthy Eating Index-2010 (HEI-2010) and Mean Adequacy Ratio (MAR), (two 24-hr recalls). A national food price database was used to estimate MVD. Multiple linear/logistic regression analyses were conducted stratifying separately by sex, race and poverty status. Women had significantly higher HEI-2010 scores than men (43.35 vs 41.57 out of 100, respectively), whereas MAR scores were higher for men (76.8 vs 69.9, out of 100), reflecting energy intake gender differentials. Importantly, a $3/day higher MVD (IQR: $3.70/d (Q1) to $6.62/d (Q4)) was associated with a 4.98±0.35 higher total HEI-2010 and a 3.88±0.37 higher MAR score, after energy-adjustment and control for key confounders. For HEI-2010 and MAR, stronger associations were observed among participants above poverty and among women, whilethe MVD vs. HEI-2010 association was additionally stronger among Whites. Sex and poverty status differentials were observed for many MAR and some HEI-2010 components. Despite positive associations between measures of dietary quality and MVD, particularly above poverty and among women, approaching compliance with the Dietary Guidelines (80 or more for HEI-2010) requires a substantially higher MVD. Thus, nutrition education may further improve people's decision-making regarding food venues and dietary choices.

  5. Monetary Value of Diet Is Associated with Dietary Quality and Nutrient Adequacy among Urban Adults, Differentially by Sex, Race and Poverty Status

    PubMed Central

    Beydoun, May A.; Fanelli-Kuczmarski, Marie T.; Allen, Allyssa; Beydoun, Hind A.; Popkin, Barry M.; Evans, Michele K.; Zonderman, Alan B.

    2015-01-01

    Objective The association between monetary value of the diet (MVD, $/day) with dietary quality was examined using a large sample of urban US adults, differentially by socio-demographic factors. Methods This was a cross-sectional study of 2,111 participants, aged 30–64y, using data from the Healthy Aging in Neighborhoods of Diversity across the Life Span Study. Dietary quality indices included Healthy Eating Index–2010 (HEI–2010) and Mean Adequacy Ratio (MAR), (two 24-hr recalls). A national food price database was used to estimate MVD. Multiple linear/logistic regression analyses were conducted stratifying separately by sex, race and poverty status. Results Women had significantly higher HEI-2010 scores than men (43.35 vs 41.57 out of 100, respectively), whereas MAR scores were higher for men (76.8 vs 69.9, out of 100), reflecting energy intake gender differentials. Importantly, a $3/day higher MVD (IQR: $3.70/d (Q1) to $6.62/d (Q4)) was associated with a 4.98±0.35 higher total HEI-2010 and a 3.88±0.37 higher MAR score, after energy-adjustment and control for key confounders. For HEI-2010 and MAR, stronger associations were observed among participants above poverty and among women, whilethe MVD vs. HEI-2010 association was additionally stronger among Whites. Sex and poverty status differentials were observed for many MAR and some HEI-2010 components. Conclusions Despite positive associations between measures of dietary quality and MVD, particularly above poverty and among women, approaching compliance with the Dietary Guidelines (80 or more for HEI-2010) requires a substantially higher MVD. Thus, nutrition education may further improve people’s decision-making regarding food venues and dietary choices. PMID:26536243

  6. Fat intake and its relationship with pre- and post-menopausal breast cancer risk: a case-control study in Malaysia.

    PubMed

    Sulaiman, Suhaina; Shahril, Mohd Razif; Shaharudin, Soraya Hanie; Emran, Nor Aina; Muhammad, Rohaizak; Ismail, Fuad; Husain, Sharifah Noor Akmal Syed

    2011-01-01

    Fat intake has been shown to play a role in the etiology of breast cancer, but the findings have been inconsistent. To assess the association of premenopausal and postmenopausal breast cancer risk with fat and fat subtypes intake. This is a population based case-control study conducted in Kuala Lumpur, Malaysia from January 2006 to December 2007. Food intake pattern was collected from 382 breast cancer patients and 382 control group via an interviewer-administered food frequency questionnaire. Logistic regression was used to compute odds ratios (OR) with 95% confidence intervals (CI) and a broad range of potential confounders was included in analysis. This study showed that both premenopausal and postmenopausal breast cancer risk did not increase significantly with greater intake of total fat [quartile (Q) 4 versus Q1 OR=0.76, 95% CI, 0.23-2.45 and OR=1.36, 95% CI, 0.30-3.12], saturated fat (ORQ4 to Q1=1.43, 95% CI, 0.51-3.98 and ORQ4 to Q1=1.75, 95% CI, 0.62-3.40), monounsaturated fat (ORQ4 to Q1=0.96, 95% CI, 0.34-1.72 and ORQ4 to Q1=1.74, 95% CI, 0.22-2.79), polyunsaturated fat (ORQ4 to Q1=0.64, 95% CI, 0.23-1.73 and ORQ4 to Q1=0.74, 95% CI, 0.39-1.81), n-3 polyunsaturated fat (ORQ4 to Q1=1.10, 95% CI, 0.49-2.48 and ORQ4 to Q1=0.78, 95% CI, 0.28-2.18), n-6 polyunsaturated fat (ORQ4 to Q1=0.67, 95% CI, 0.24-1.84 and ORQ4 to Q1=0.71, 95% CI, 0.29-1.04) or energy intake (ORQ4 to Q1=1.52, 95% CI, 0.68-3.38 and ORQ4 to Q1=2.21, 95% CI, 0.93-3.36). Total fat and fat subtypes were not associated with pre- and postmenopausal breast cancer risk after controlling for age, other breast cancer risk factors and energy intake. Despite the lack of association, the effects of total fat and fat subtypes intake during premenopausal years towards postmenopausal breast cancer risk still warrant investigation.

  7. The fundamental science of nitrogen-doping of niobium superconducting cavities

    NASA Astrophysics Data System (ADS)

    Gonnella, Daniel Alfred

    Doping of niobium superconducting RF cavities with impurities has been demonstrated to have the ability to significantly improve the cryogenic efficiency of the accelerating structures. Doping SRF cavities with nitrogen is a relatively simple additional step to cavity preparation that can make drastic improvements in a cavity's intrinsic quality factor, Q0. Nitrogen-doping consists of treating SRF cavities at high temperatures in a low nitrogen-atmosphere. This leads to two important effects: an improvement in Q0 at low fields, and the presence of an "anti-Q slope" in which the cryogenic efficiency of doped cavities actually improves at higher fields. After its initial discovery, nitrogen-doping showed real promise but many fundamental scientific questions remained about the process. Nitrogen-doped cavities consistently quenched at lower fields than un-doped cavities, cooling the cavities through their critical temperature slowly led to poor performance, and the mechanism behind the Q0 improvement was not well understood. This dissertation focuses on addressing these issues. Single-cell 1.3 GHz cavities were prepared with different nitrogen-dopings and their effects studied systematically. It was found that nitrogen-doping drastically lowers the mean free path of the RF penetration layer of the niobium, leading to a lowering of the temperature-dependent BCS resistance, RBCS, at low fields. Theoretical work to predict the anti-Q slope was compared with experimental results to more fundamentally understand the nature of the field dependence of RBCS. Nitrogen-doped cavities were found to have a much larger sensitivity of residual resistance from trapped magnetic flux than un-doped cavities. Fast cool downs with large spatial temperature gradients through Tc were found to more efficiently expel magnetic flux. The full dependence of this sensitivity to trapped magnetic flux was studied as a function of changing mean free path and found to be in good agreement with theoretical predictions. The nature of the low-field quench in nitrogen-doped cavities was also studied with high power pulsed measurements and found to be related to a lowering of the lower critical field, Bc1 due to lowering of the mean free path. Finally, five cryomodule tests were carried out on nitrogen-doped 9-cell cavities to understand how the cryomodule environment affects the performance of doped cavities. This is the first demonstration that environmental factors can be controlled to achieve high Q0 of more than 2.7x10 10 at 16 MV/m and 2.0 K in a cryomodule, meeting and exceeding the specification for LCLS-II. The work presented here represents a significant leap forward in the understanding of the underlying science behind nitrogen-doped cavities and demonstrates their readiness for use in future particle accelerators.

  8. More similarities than differences between men and women with irritable bowel syndrome.

    PubMed

    Björkman, I; Jakobsson Ung, E; Ringström, G; Törnblom, H; Simrén, M

    2015-06-01

    Differences regarding symptoms, coping abilities, and quality of life (QOL) between men and women with irritable bowel syndrome (IBS) have been reported but data are sparse and sometimes conflicting. The aim of present study was to investigate gender differences in gastrointestinal, extra-intestinal, and psychological symptoms, and sense of coherence (SOC) and QOL in a large group of patients diagnosed with IBS. We analyzed questionnaire data from 557 patients (152 men) diagnosed with IBS consecutively included in studies at an outpatient clinic for functional bowel disorders between 2002 and 2010. Following questionnaires were included: IBS severity scoring system (IBS-SSS), Hospital Anxiety and Depression Scale (HAD), IBSQOL Scale, Visceral Sensitivity Index (VSI), SOC Scale, Bristol Stool Form Scale (BSFS), and Patient Health Questionnaire (PHQ-15). Women had harder stools (FDR-adjusted p-value: q = 0.033), more severe bloating (q = 0.020), higher symptom severity (q = 0.042), higher total somatic symptom burden (q = 0.035), lower SOC (q = 0.042), and lower QOL. Women rated more general anxiety (q = 0.017) and gastrointestinal-specific anxiety (q = 0.042), but there were no group differences in depression, pain, stool frequency, impact on daily life, dissatisfaction with bowel habit, or extra-colonic symptoms. The differences found were small (effect sizes: r < 0.3). In this study, we demonstrated more similarities than differences between men and women with IBS. The largest difference were seen for QOL which might reflect certain structural stressors to which women in general are more exposed than men. © 2015 John Wiley & Sons Ltd.

  9. Fertility after uterine artery embolization for symptomatic multiple fibroids with no other infertility factors.

    PubMed

    Torre, Antoine; Fauconnier, Arnaud; Kahn, Vanessa; Limot, Olivier; Bussierres, Laurence; Pelage, Jean Pierre

    2017-07-01

    To evaluate the fertility of women eligible for surgical multiple myomectomy, but who carefully elected a fertility-sparing uterine artery embolization (UAE). Non-comparative open-label trial, on women ≤40 years, presenting with multiple symptomatic fibroids (at least 3, ≥3 cm), immediate pregnancy wish, and no associated infertility factor. Women had a bilateral limited UAE using tris-acryl gelatin microspheres ≥500 μm. Fertility, ovarian reserve, uterus and fibroid sizes, and quality of life questionnaires (UFS-QoL) were prospectively followed. Fifteen patients, aged 34.8 years (95%CI 32.2-37.5, median 36.0, q1-q3 29.4-39.5) were included from November 2008 to May 2012. During the year following UAE, 9 women actively attempting to conceive experienced 5 live-births (intention-to-treat fertility rate 33.3%, 95%CI 11.8%-61.6%). Markers of ovarian reserve remained stable. The symptoms score was reduced by 66% (95%CI 48%-85%) and the quality of life score was improved by 112% (95%CI 21%-204%). Uterine volume was reduced by 38% (95%CI 24%-52%). Women were followed for 43.1 months (95%CI 32.4-53.9), 10 live-births occurred in 8 patients, and 5 patients required secondary surgeries for fibroids. Women without associated infertility factors demonstrated an encouraging capacity to deliver after UAE. Further randomized controlled trials comparing UAE and myomectomy are warranted. • Women without infertility factors showed an encouraging delivery rate after UAE. • For women choosing UAE over abdominal myomectomy, childbearing may not be impaired. • Data are insufficient to definitively recommend UAE as comparable to myomectomy. • Further randomized trials comparing fertility after UAE or myomectomy are warranted.

  10. Individual and Combined Effects of Dietary Factors on Risk of Incident Hypertension: Prospective Analysis From the NutriNet-Santé Cohort.

    PubMed

    Lelong, Helene; Blacher, Jacques; Baudry, Julia; Adriouch, Solia; Galan, Pilar; Fezeu, Leopold; Hercberg, Serge; Kesse-Guyot, Emmanuelle

    2017-10-01

    Dietary intake is pointed as one of the major determinants in hypertension development. Data in the area are mostly obtained from cross-sectional studies. We aimed to investigate the prospective association between (1) individual nutritional factors and (2) adherence to the Dietary Approach to Stop Hypertension and the risk of incident hypertension in a large cohort study. We prospectively examined the incidence of hypertension among 80 426 French adults participating in the NutriNet-Santé cohort study. Self-reported sociodemographic, lifestyle health questionnaires and dietary consumption assessed by three 24-hour records were completed at baseline and yearly thereafter. Associations between quartiles (Q) of nutrients and food groups and adherence to Dietary Approach to Stop Hypertension diet and hypertension risk were assessed by multivariable Cox proportional hazards models. During a mean follow-up of 3.4±2.1 years, 2413 cases of incident hypertension were documented. Dietary intakes of sodium (Q4 versus Q1): hazard ratio (HR)=1.17 (95% confidence interval [CI], 1.02-1.35), potassium: HR=0.82 (95% CI, 0.72-0.94), animal protein: HR=1.26 (95% CI, 1.11-1.43), vegetable protein: HR=0.85 (95% CI, 0.75-0.95), fiber: HR =0.81 (95% CI, 0.71-0.93), magnesium: HR=0.77 (95% CI, 0.67-0.89), fruit and vegetables: HR=0.85 (95% CI, 0.74-0.97), whole grain: HR=0.84(95% CI, 0.76-0.93), nuts: HR=0.72 (95% CI, 0.63-0.83), and red and processed meat: HR=1.25 (95% CI, 1.11-0.42) were associated with risk of hypertension. Besides, adherence to the Dietary Approach to Stop Hypertension was strongly inversely associated with incident hypertension: (Q4 versus Q1) HR=0.66 (95% CI, 0.58-0.75). Our results confirmed the association of several nutritional factors intake and incident hypertension and highlighted that adopting a global healthy diet could strongly contribute to the prevention of hypertension. © 2017 American Heart Association, Inc.

  11. IBD-INFO Questionnaire: A Multicenter French Up-to-Date Survey of Patient Knowledge in Inflammatory Bowel Disease.

    PubMed

    Danion, Pauline; Buisson, Anthony; Roblin, Xavier; Mathieu, Nicolas; Charlois, Anne-Laure; Borgerding, Joshua N; Williet, Nicolas; Del Tedesco, Emilie; Flourié, Bernard; Nancey, Stéphane; Boschetti, Gilles

    2018-04-23

    It has been demonstrated in many chronic conditions, including inflammatory bowel disease (IBD), that better patient knowledge about pathology and treatment improves the course and management of disease. The aim of this study was to develop an updated self-questionnaire to assess patients' level of knowledge of IBD. The IBD-INFO included 3 parts: an original part (Q1) and 2 parts from the translation of the preexisting questionnaires Crohn's and Colitis Knowledge score (CCKNOW) (Q2) and Crohn's and Colitis Pregnancy Knowledge score (CCPKNOW) (Q3). The reliability and discriminatory ability of the questionnaire were validated in 3 groups of non-IBD volunteers with various theoretical knowledge levels. The final questionnaire (64 validated questions) was then tested on 364 in- and out- IBD patients from 4 French university hospitals. The score for each part of the questionnaire was calculated, and factors associated with low scores were identified by univariate and multivariate logistic regression analyses. The scores obtained by the 3 non-IBD volunteer groups differed significantly (P < 0.0001), and the IBD-INFO questionnaire showed excellent internal reliability and consistency (α = 0.98). The median total score obtained by the IBD patients was 27/64 (range, 0-59), and scores for Q1, Q2, and Q3 were, respectively, 10/23 (range, 0-21), 11/24 (range, 0-23), and 4/17 (range, 0-16). In multivariate analysis, lack of a university degree, not being a member of a patient association, not receiving anti-tumor necrosis factor alpha (anti-TNFα) treatment, duration of IBD ≤3 years, male sex, and age >38 years were independent risk factors of a poor IBD-INFO knowledge score. The areas of knowledge least mastered were vaccination, IBD-related cancers, treatments, and pregnancy. Using the IBD-INFO, an updated self-administered questionnaire built to assess IBD patients' knowledge, several risk factors have been highlighted that allow better targeting of patients and areas requiring an improvement in the level of information.

  12. DNA methylation levels at chromosome 8q24 in peripheral blood are associated with 8q24 cancer susceptibility loci.

    PubMed

    Barry, Kathryn Hughes; Moore, Lee E; Sampson, Joshua; Yan, Liying; Meyer, Ann; Oler, Andrew J; Chung, Charles C; Wang, Zhaoming; Yeager, Meredith; Amundadottir, Laufey; Berndt, Sonja I

    2014-12-01

    Chromosome 8q24 has emerged as an important region for genetic susceptibility to various cancers, but little is known about the contribution of DNA methylation at 8q24. To evaluate variability in DNA methylation levels at 8q24 and the relationship with cancer susceptibility single nucleotide polymorphisms (SNPs) in this region, we quantified DNA methylation levels in peripheral blood at 145 CpG sites nearby 8q24 cancer susceptibility SNPs or MYC using pyrosequencing among 80 Caucasian men in the Prostate, Lung, Colorectal, and Ovarian Cancer Screening Trial. For the 60 CpG sites meeting quality control, which also demonstrated temporal stability over a 5-year period, we calculated pairwise Spearman correlations for DNA methylation levels at each CpG site with 42 8q24 cancer susceptibility SNPs. To account for multiple testing, we adjusted P values into q values reflecting the false discovery rate (FDR). In contrast to the MYC CpG sites, most sites nearby the SNPs demonstrated good reproducibility, high methylation levels, and moderate-high between-individual variation. We observed 10 statistically significant (FDR < 0.05) CpG site-SNP correlations. These included correlations between an intergenic CpG site at Chr8:128393157 and the prostate cancer SNP rs16902094 (ρ = -0.54; P = 9.7 × 10(-7); q = 0.002), a PRNCR1 CpG site at Chr8:128167809 and the prostate cancer SNP rs1456315 (ρ = 0.52; P = 1.4 × 10(-6); q = 0.002), and two POU5F1B CpG sites and several prostate/colorectal cancer SNPs (for Chr8:128498051 and rs6983267, ρ = 0.46; P = 2.0 × 10(-5); q = 0.01). This is the first report of correlations between blood DNA methylation levels and cancer susceptibility SNPs at 8q24, suggesting that DNA methylation at this important susceptibility locus may contribute to cancer risk. ©2014 American Association for Cancer Research.

  13. Optical investigation of domain resonances in magnetic garnet films

    NASA Astrophysics Data System (ADS)

    Bahlmann, N.; Gerhardt, R.; Dötsch, H.

    1996-08-01

    Magnetic garnet films of composition (Y,Bi) 3(Fe,Al) 5O 12 are grown by liquid phase epitaxy on [111] oriented substrates of Gd 3Ga 5O 12. Lattices of parallel stripe domains are stabilized by a static induction applied in the film plane. The two branches DR ± of the domain resonance and the domain wall resonance DWR are excited by microwave magnetic fields in the frequency range up to 6 GHz. Light passing the stripe domain lattice parallel to the film normal is modulated at the excitation frequency. A modulation bandwidth of more than 2 GHz is observed. The resonances can be calculated with high accuracy by a hybridization model, if the quality factor Q of the film exceeds 0.5. For Q < 0.5 a simple approximation is used to describe the superposition of the DR + and DR - resonances. The superposition model predicts two stability states of the resonance DR + which are observed experimentally. From the optical measurements precession angles of the resonance DR - of nearly 6° and wall oscillation amplitudes up to 25 nm are derived.

  14. Association of the type of 5q loss with complex karyotype, clonal evolution, TP53 mutation status, and prognosis in acute myeloid leukemia and myelodysplastic syndrome.

    PubMed

    Volkert, Sarah; Kohlmann, Alexander; Schnittger, Susanne; Kern, Wolfgang; Haferlach, Torsten; Haferlach, Claudia

    2014-05-01

    We analyzed 1,200 patients with acute myeloid leukemia (AML) and myelodysplastic syndrome (MDS) harboring a 5q deletion in order to clarify whether the type of 5q loss is associated with other biological markers and prognosis. We investigated all patients by chromosome banding analysis, FISH with a probe for EGR1 (5q31) and, if necessary, to resolve complex karyotypes with 24-color-FISH. Moreover, 420 patients were analyzed for mutations in the TP53 gene. The patient cohort was subdivided based on type of 5q loss: Patients with interstitial deletions and patients with 5q loss due to unbalanced rearrangements or monosomy 5. Loss of the long arm of chromosome 5 due to an unbalanced rearrangement occurred more often in AML (286/627; 45.6%) than MDS (188/573; 32.8%; P < 0.001). In both entities, patients with 5q loss due to unbalanced translocations showed complex karyotypes more frequently (MDS: 179/188; 95.2% vs. 124/385; 32.2%; P < 0.001; AML: 274/286; 95.8% vs. 256/341; 75.1%; P < 0.001). Moreover, in MDS unbalanced 5q translocations were associated with clonal evolution (109/188; 58.0% vs. 124/385; 32.2%; P < 0.001), mutation of TP53 (64/67; 95.5% vs. 40/120; 40.0%; P < 0.001), and shorter survival (15.3 months vs. not reached; P < 0.001). In MDS, complex karyotype was an independent adverse prognostic factor (HR = 5.34; P = 0.032), whereas in AML presence of TP53 mutations was the strongest adverse prognostic factor (HR = 2.21; P = 0.026). In conclusion, in AML and MDS, loss of the long arm of chromosome 5 due to unbalanced translocations is associated with complex karyotype and in MDS, moreover, with clonal evolution, mutations in the TP53 gene and adverse prognosis. Copyright © 2014 Wiley Periodicals, Inc.

  15. X-ray variability and the inner region in active galactic nuclei

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mohan, P.; Mangalam, A., E-mail: prashanth@iiap.res.in, E-mail: mangalam@iiap.res.in

    2014-08-20

    We present theoretical models of X-ray variability attributable to orbital signatures from an accretion disk including emission region size, quasi-periodic oscillations (QPOs), and its quality factor Q, and the emergence of a break frequency in the power spectral density shape. We find a fractional variability amplitude of F{sub var}∝M{sub ∙}{sup −0.4}. We conduct a time series analysis on X-ray light curves (0.3-10 keV) of a sample of active galactic nuclei (AGNs). A statistically significant bend frequency is inferred in 9 of 58 light curves (16%) from 3 AGNs for which the break timescale is consistent with the reported BH spinmore » but not with the reported BH mass. Upper limits of 2.85 × 10{sup 7} M {sub ☉} in NGC 4051, 8.02 × 10{sup 7} M {sub ☉} in MRK 766, and 4.68 × 10{sup 7} M {sub ☉} in MCG-6-30-15 are inferred for maximally spinning BHs. For REJ 1034+396 where a QPO at 3733 s was reported, we obtain an emission region size of (6-6.5) M and a BH spin of a ≲ 0.08. The relativistic inner region of a thin disk, dominated by radiation pressure and electron scattering, is likely to host the orbital features as the simulated Q ranges from 6.3 × 10{sup –2} to 4.25 × 10{sup 6}, containing the observed Q. The derived value of Q ∼ 32 for REJ 1034+396 therefore suggests that the AGN hosts a thin disk.« less

  16. Single nucleotide polymorphism rs3774261 in the AdipoQ gene is associated with the risk of coronary heart disease (CHD) in Northeast Han Chinese population: a case-control study.

    PubMed

    Kanu, Joseph Sam; Gu, Yulu; Zhi, Sun; Yu, Mingxi; Lu, Yuping; Cong, Yetong; Liu, Yunkai; Li, Yong; Yu, Yaqin; Cheng, Yi; Liu, Yawen

    2016-01-12

    Coronary Heart Disease (CHD) is one of the leading causes of death in the world with a projected global 82 million DALYs by 2020. Genetic and environmental factors contribute to CHD development. Here, the authors investigate the association between CHD risk and three Single Nucleotide Polymorphisms (SNPs) in the AdipoQ gene (rs3774261, rs1063537 and rs2082940); and the interaction of this association with environmental factors, in Northeast Han Chinese population. Using a case-control study design, 1514 participants (754 cases and 760 controls) were investigated. Three variants in the AdipoQ gene (rs3774261, rs1063537 and rs2082940) were selected and genotyped. The online SNPstats program and SPSS 21.0 software were used for data analyses. The authors found that the rs3774261G allele is associated with the risk of CHD but that the rs2082940T allele protects against CHD. No significant association was found between rs1063537 and CHD risk. The study also found significant interactions between triglyceride levels and the SNPs studied (P < 0.0001 for rs3774261, P = 0.014 for rs1063537, and P = 0.031 for rs2082940). Variations in AdipoQ gene can protect against CHD (as with rs2082940T) or associated with CHD risk (as with rs3774261G) in Northeast Han Chinese - findings that will help shed light on the reported conflicting roles of AdipoQ in cardiovascular diseases. Serum triglycerides levels also interact in the AdipoQ - CHD association, thus further highlighting the roles environmental factors play in the genetic aspect of diseases.

  17. Commissioning results of Nb 3Sn cavity vapor diffusion deposition system at JLab

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eremeev, Grigory; Clemens, William A.; Macha, Kurt M.

    2015-09-01

    Nb 3Sn as a BCS superconductor with a superconducting critical temperature higher than that of niobium offers potential benefit for SRF cavities via a lower-than-niobium surface resistance at the same temperature and frequency. A Nb 3Sn vapor diffusion deposition system designed for coating of 1.5 and 1.3 GHz single-cell cavities was built and commissioned at JLab. As the part of the commissioning, RF performance at 2.0 K of a single-cell 1.5 GHz CEBAF-shaped cavity was measured before and after coating in the system. Before Nb 3Sn coating the cavity had a Q 0 of about 10 10 and was limitedmore » by the high field Q-slope at E acc ≅ 27 MV/m. Coated cavity exhibited the superconducting transition at about 17.9 K. The low-field quality factor was about 5∙10 9 at 4.3 K and 7∙10 9 at 2.0 K decreasing with field to about 1∙10 9 at E acc ≅ 8 MV/m at both temperatures. The highest field was limited by the available RF power.« less

  18. Characterization of Hard Piezoelectric Lead-Free Ceramics

    PubMed Central

    Zhang, Shujun; Lim, Jong Bong; Lee, Hyeong Jae; Shrout, Thomas R.

    2010-01-01

    K4CuNb8O23 doped K0.45Na0.55NbO3 (KNN-KCN) ferroelectric ceramics were found to exhibit asymmetrical polarization hysteresis loops, related to the development of an internal bias field. The internal bias field is believed to be the result of defect dipoles of acceptor ions and oxygen vacancies, which lead to piezoelectric “hardening” effect, by stabilizing and pinning of the domain wall motion. The dielectric loss for the hard lead-free piezoelectric ceramic was found to be 0.6%, with mechanical quality factors Q on the order of >1500. Furthermore, the piezoelectric properties were found to decrease and the coercive field increased, when compared with the undoped material, exhibiting a typical characteristic of “hard” behavior. The temperature usage range was limited by the polymorphic phase transition temperature, being 188°C. The full set of material constants was determined for the KNN-KCN materials. Compared with conventional hard PZT ceramics, the lead-free possessed lower dielectric and piezoelectric properties; however, comparable values of mechanical Q, dielectric loss, and coercive fields were obtained, making acceptor modified KNN based lead-free piezoelectric material promising for high-power applications, where lead-free materials are desirable. PMID:19686966

  19. Measurement of the N→Δ+(1232) Transition at High-Momentum Transfer by π0 Electroproduction

    NASA Astrophysics Data System (ADS)

    Ungaro, M.; Stoler, P.; Aznauryan, I.; Burkert, V. D.; Joo, K.; Smith, L. C.; Adams, G.; Amarian, M.; Ambrozewicz, P.; Anghinolfi, M.; Asryan, G.; Audit, G.; Avakian, H.; Bagdasaryan, H.; Ball, J. P.; Baltzell, N. A.; Barrow, S.; Batourine, V.; Battaglieri, M.; Bedliski, I.; Bektasoglu, M.; Bellis, M.; Benmouna, N.; Berman, B. L.; Biselli, A. S.; Bonner, B. E.; Bouchigny, S.; Boiarinov, S.; Bradford, R.; Branford, D.; Briscoe, W. J.; Brooks, W. K.; Bültmann, S.; Butuceanu, C.; Calarco, J. R.; Careccia, S. L.; Carman, D. S.; Cazes, A.; Chen, S.; Cole, P. L.; Coltharp, P.; Cords, D.; Corvisiero, P.; Crabb, D.; Cummings, J. P.; Sanctis, E. De; Devita, R.; Degtyarenko, P. V.; Denizli, H.; Dennis, L.; Deur, A.; Dharmawardane, K. V.; Djalali, C.; Dodge, G. E.; Donnelly, J.; Doughty, D.; Dugger, M.; Dytman, S.; Dzyubak, O. P.; Egiyan, H.; Egiyan, K. S.; Elouadrhiri, L.; Eugenio, P.; Fatemi, R.; Fedotov, G.; Feldman, G.; Feuerbach, R. J.; Funsten, H.; Garçon, M.; Gavalian, G.; Gilfoyle, G. P.; Giovanetti, K. L.; Girod, F. X.; Goetz, J.; Gordon, C. I. O.; Gothe, R. W.; Griffioen, K. A.; Guidal, M.; Guillo, M.; Guler, N.; Guo, L.; Gyurjyan, V.; Hadjidakis, C.; Hakobyan, R. S.; Hardie, J.; Heddle, D.; Hersman, F. W.; Hleiqawi, I.; Holtrop, M.; Hicks, K.; Hyde-Wright, C. E.; Ilieva, Y.; Ireland, D. G.; Ishkhanov, B. S.; Ito, M. M.; Jenkins, D.; Jo, H. S.; Juengst, H. G.; Kellie, J. D.; Khandaker, M.; Kim, W.; Klein, A.; Klein, F. J.; Klimenko, A. V.; Kossov, M.; Kramer, L. H.; Kubarovsky, V.; Kuhn, J.; Kuhn, S. E.; Lachniet, J.; Laget, J. M.; Langheinrich, J.; Lawrence, D.; Lee, T.; Li, Ji; Livingston, K.; Marchand, C.; Markov, N.; McAleer, S.; McKinnon, B.; McNabb, J. W. C.; Mecking, B. A.; Mehrabyan, S.; Melone, J. J.; Mestayer, M. D.; Meyer, C. A.; Mikhailov, K.; Minehart, R.; Mirazita, M.; Miskimen, R.; Mokeev, V.; Morand, L.; Morrow, S. A.; Mueller, J.; Mutchler, G. S.; Napolitano, J.; Nasseripour, R.; Niccolai, S.; Niculescu, G.; Niculescu, I.; Niczyporuk, B. B.; Niroula, M.; Niyazov, R. A.; Nozar, M.; O'Rielly, G. V.; Osipenko, M.; Ostrovidov, A. I.; Park, K.; Pasyuk, E.; Philips, S. A.; Pivnyuk, N.; Pocanic, D.; Pogorelko, O.; Polli, E.; Pozdniakov, S.; Preedom, B. M.; Price, J. W.; Prok, Y.; Protopopescu, D.; Qin, L. M.; Raue, B. A.; Riccardi, G.; Ricco, G.; Ripani, M.; Ritchie, B. G.; Ronchetti, F.; Rosner, G.; Rossi, P.; Rubin, P. D.; Sabatié, F.; Salgado, C.; Santoro, J. P.; Sapunenko, V.; Schumacher, R. A.; Serov, V. S.; Sharabian, Y. G.; Skabelin, A. V.; Smith, E. S.; Sober, D. I.; Stavinsky, A.; Stepanyan, S. S.; Stepanyan, S.; Stokes, B. E.; Strakovsky, I. I.; Strauch, S.; Taiuti, M.; Tedeschi, D. J.; Thoma, U.; Tkabladze, A.; Todor, L.; Tkachenko, S.; Tur, C.; Vineyard, M. F.; Vlassov, A. V.; Weinstein, L. B.; Weygand, D. P.; Williams, M.; Wolin, E.; Wood, M. H.; Yegneswaran, A.; Zana, L.; Zhang, B.; Zhang, J.; Zhao, B.

    2006-09-01

    We report a new measurement of the exclusive electroproduction reaction γ*p→π0p to explore the evolution from soft nonperturbative physics to hard processes via the Q2 dependence of the magnetic (M1+), electric (E1+), and scalar (S1+) multipoles in the N→Δ transition. 9000 differential cross section data points cover W from threshold to 1.4GeV/c2, 4π center-of-mass solid angle, and Q2 from 3 to 6GeV2/c2, the highest yet achieved. It is found that the magnetic form factor GM* decreases with Q2 more steeply than the proton magnetic form factor, the ratio E1+/M1+ is small and negative, indicating strong helicity nonconservation, and the ratio S1+/M1+ is negative, while its magnitude increases with Q2.

  20. JLab Measurements of the He 3 Form Factors at Large Momentum Transfers

    DOE PAGES

    Camsonne, A.; Katramatou, A. T.; Olson, M.; ...

    2017-10-19

    The charge and magnetic form factors, F C and F M, respectively, of 3He are extracted in the kinematic range 25 fm –2 ≤ Q 2 ≤ 61 fm –2 from elastic electron scattering by detecting 3He recoil nuclei and scattered electrons in coincidence with the two High Resolution Spectrometers of the Hall A Facility at Jefferson Lab. The measurements find evidence for the existence of a second diffraction minimum for the magnetic form factor at Q 2 = 49.3 fm –2 and for the charge form factor at Q 2 = 62.0 fm –2. Both minima are predicted tomore » exist in the Q 2 range accessible by this Jefferson Lab experiment. Here, the data are in qualitative agreement with theoretical calculations based on realistic interactions and accurate methods to solve the three-body nuclear problem.« less

  1. JLab Measurements of the He 3 Form Factors at Large Momentum Transfers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Camsonne, A.; Katramatou, A. T.; Olson, M.

    The charge and magnetic form factors, F C and F M, respectively, of 3He are extracted in the kinematic range 25 fm –2 ≤ Q 2 ≤ 61 fm –2 from elastic electron scattering by detecting 3He recoil nuclei and scattered electrons in coincidence with the two High Resolution Spectrometers of the Hall A Facility at Jefferson Lab. The measurements find evidence for the existence of a second diffraction minimum for the magnetic form factor at Q 2 = 49.3 fm –2 and for the charge form factor at Q 2 = 62.0 fm –2. Both minima are predicted tomore » exist in the Q 2 range accessible by this Jefferson Lab experiment. Here, the data are in qualitative agreement with theoretical calculations based on realistic interactions and accurate methods to solve the three-body nuclear problem.« less

  2. Tunable Q-factor silicon microring resonators for ultra-low power parametric processes.

    PubMed

    Strain, Michael J; Lacava, Cosimo; Meriggi, Laura; Cristiani, Ilaria; Sorel, Marc

    2015-04-01

    A compact silicon ring resonator is demonstrated that allows simple electrical tuning of the ring coupling coefficient and Q-factor and therefore the resonant enhancement of on-chip nonlinear optical processes. Fabrication-induced variation in designed coupling fraction, crucial in the resonator performance, can be overcome using this post-fabrication trimming technique. Tuning of the microring resonator across the critical coupling point is demonstrated, exhibiting a Q-factor tunable between 9000 and 96,000. Consequently, resonantly enhanced four-wave mixing shows tunable efficiency between -40 and -16.3  dB at an ultra-low on-chip pump power of 0.7 mW.

  3. Communicating and visualizing data quality through Web Map Services

    NASA Astrophysics Data System (ADS)

    Roberts, Charles; Blower, Jon; Maso, Joan; Diaz, Daniel; Griffiths, Guy; Lewis, Jane

    2014-05-01

    The sharing and visualization of environmental data through OGC Web Map Services is becoming increasingly common. However, information about the quality of data is rarely presented. (In this presentation we consider mostly data uncertainty as a measure of quality, although we acknowledge that many other quality measures are relevant to the geoscience community.) In the context of the GeoViQua project (http://www.geoviqua.org) we have developed conventions and tools for using WMS to deliver data quality information. The "WMS-Q" convention describes how the WMS specification can be used to publish quality information at the level of datasets, variables and individual pixels (samples). WMS-Q requires no extensions to the WMS 1.3.0 specification, being entirely backward-compatible. (An earlier version of WMS-Q was published as OGC Engineering Report 12-160.) To complement the WMS-Q convention, we have also developed extensions to the OGC Symbology Encoding (SE) specification, enabling uncertain geoscience data to be portrayed using a variety of visualization techniques. These include contours, stippling, blackening, whitening, opacity, bivariate colour maps, confidence interval triangles and glyphs. There may also be more extensive applications of these methods beyond the visual representation of uncertainty. In this presentation we will briefly describe the scope of the WMS-Q and "extended SE" specifications and then demonstrate the innovations using open-source software based upon ncWMS (http://ncwms.sf.net). We apply the tools to a variety of datasets including Earth Observation data from the European Space Agency's Climate Change Initiative. The software allows uncertain raster data to be shared through Web Map Services, giving the user fine control over data visualization.

  4. Quarantine versus pathogen-reduced plasma-coagulation factor content and rotational thromboelastometry coagulation.

    PubMed

    Theusinger, Oliver M; Goslings, David; Studt, Jan-Dirk; Brand-Staufer, Brigitte; Seifert, Burkhardt; Spahn, Donat R; Frey, Beat M

    2017-03-01

    Different types of fresh-frozen plasma (FFP) exist, and the concentrations of plasma proteins vary between individuals and blood groups. Furthermore, processing may also influence the content. Quarantine-stored plasma (qFFP) and plasma that was pathogen-reduced using blood-safety (Intercept) technology (piFFP) were analyzed regarding procoagulant and anticoagulant hemostasis proteins, including endogenous thrombin (thrombin-generation) potential (ETP). Thirty-five samples of each type of FFP were analyzed using only male Blood Group O donors. FFP units were stored frozen for comparable periods of time before plasma protein content was assessed. Once the units were thawed, all tests were completed within 4 hours. The results are presented as means ± standard deviations or as median (minimum; maximum) and were compared using independent-sample t tests (significance, p < 0.01). Significantly higher concentrations of adintegrin-like and metalloprotease with thrombospondin type-13 motifs (ADAMTS13), fibrinogen, Factor (F)V, FVIII, FXIII, protein S, protein S activity, antithrombin, microvesicle (<900 nm), and α2 antiplasmin were observed in qFFP. The variability of factors was significantly lower in piFFP. Tissue factor (TF) at 1 picomolar (pM) exhibited significantly longer lag time, a lower peak, lower ETP, and a lower velocity index in qFFP compared with piFFP. In TF at 5 pM, significant differences in lag time (longer in qFFP), velocity index (lower in qFFP), and peak (lower in qFFP) were observed. Rotational thromboelastometry revealed a significantly longer (p = 0.002) clot-formation time with intrinsic thromboelastometry for piFFP and a significantly shorter clotting time (p = 0.004) with thromboelastometry fibrinogen testing for piFFP. Pathogen reduction reduces procoagulant and anticoagulant coagulation factors as well as variability. A thrombin-generation assay showed no reduced ETP and no supraphysiological thrombin generation. None of the FFP preparations is likely to be effective for treating fibrinogen deficiency. © 2016 AABB.

  5. Decay constants and radiative decays of heavy mesons in light-front quark model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choi, Ho-Meoyng

    2007-04-01

    We investigate the magnetic dipole decays V{yields}P{gamma} of various heavy-flavored mesons such as (D,D*,D{sub s},D{sub s}*,{eta}{sub c},J/{psi}) and (B,B*,B{sub s},B{sub s}*,{eta}{sub b},{upsilon}) using the light-front quark model constrained by the variational principle for the QCD-motivated effective Hamiltonian. The momentum dependent form factors F{sub VP}(q{sup 2}) for V{yields}P{gamma}* decays are obtained in the q{sup +}=0 frame and then analytically continued to the timelike region by changing q{sub perpendicular} to iq{sub perpendicular} in the form factors. The coupling constant g{sub VP{gamma}} for real photon case is then obtained in the limit as q{sup 2}{yields}0, i.e. g{sub VP{gamma}}=F{sub VP}(q{sup 2}=0). The weak decaymore » constants of heavy pseudoscalar and vector mesons are also calculated. Our numerical results for the decay constants and radiative decay widths for the heavy-flavored mesons are overall in good agreement with the available experimental data as well as other theoretical model calculations.« less

  6. Polarization-dependent electromagnetic responses of ultrathin and highly flexible asymmetric terahertz metasurfaces

    NASA Astrophysics Data System (ADS)

    Burrow, Joshua A.; Yahiaoui, Riad; Sarangan, Andrew; Agha, Imad; Mathews, Jay; Searles, Thomas A.

    2017-12-01

    We report the polarization-dependent electromagnetic response from a series of novel terahertz (THz) metasurfaces where asymmetry is introduced through the displacement of two adjacent metallic arms separated by a distance $\\delta$. For all polarization states, the symmetric metasurface exhibits a low quality (Q) factor fundamental dipole mode. By breaking the symmetry, we experimentally observe a secondary dipole-like mode with a Q factor nearly $9\\times$ higher than the fundamental resonance. As $\\delta$ increases, the fundamental dipole mode $f_{1}$ redshifts and the secondary mode $f_{2}$ blueshifts creating a highly transmissive spectral window. Polarization-dependent measurements reveal a full suppression of $f_{2}$ for all asymmetries at $\\theta \\geq 60^\\circ$. Furthermore, at $\\delta \\geq 60 \\text{ }\\mu\\text{m}$, we observe a polarization selective electromagnetic induced transparency (EIT) for the fundamental mode. This work paves the way for applications in filtering, sensing and slow-light devices common to other high Q factor THz metasurfaces with EIT-like response.

  7. A Novel Symmetrical Split Ring Resonator Based on Microstrip for Microwave Sensors

    NASA Astrophysics Data System (ADS)

    Alahnomi, Rammah A.; Zakaria, Z.; Ruslan, E.; Bahar, Amyrul Azuan Mohd

    2016-02-01

    In this paper, novel symmetrical split ring resonator (SSRR) is proposed as a suitable component for performance enhancement of microwave sensors. SSRR has been employed for enhancing the insertion loss of the microwave sensors. Using the same device area, we can achieve a high Q-factor of 141.54 from the periphery enhancement using Quasi-linear coupling SSRR, whereas loose coupling SSRR can achieve a Q-factor of 33.98 only. Using Quasi-linear coupling SSRR, the Q-factor is enhanced 4.16 times the loose coupling SSRR using the same device area. After the optimization was made, the SSRR sensor with loose coupling scheme has achieved a very high Qfactor value around 407.34 while quasi-linear scheme has achieved high Q-factor value of 278.78 at the same operating frequency with smaller insertion loss. Spurious passbands at 1st, 2nd, 3rd, and 4th harmonics have been completely suppressed well above -20 dB rejection level without visible changes in the passband filter characteristics. The most significant of using SSRR is to be used for various industrial applications such as food industry, quality control, bio-sensing medicine and pharmacy. The simulation result that Quasi-linear coupling SSRR is a viable candidate for the performance enhancement of microwave sensors has been verified.

  8. Low-loss microelectrodes fabricated using reverse-side exposure for a tunable ferroelectric capacitor application

    NASA Astrophysics Data System (ADS)

    Yoon, Yong-Kyu; Stevenson Kenney, J.; Hunt, Andrew T.; Allen, Mark G.

    2006-02-01

    Narrowly spaced thick microelectrodes are fabricated using a self-aligned multiple reverse-side exposure scheme for an improved quality-factor tunable ferroelectric capacitor. The microelectrodes are fabricated on a functional substrate—a thin film ferroelectric (barium strontium titanate, BST; BaxSr1-xTiO3) coated sapphire substrate, which has an electric-field-dependent dielectric property providing tuning functionality, as well as UV transparency permitting an additional degree of freedom in photolithography steps. The microelectrode process has been applied to interdigitated capacitor fabrication, where a critical challenge is maintaining narrow gaps between electrodes for high tunability, while simultaneously forming thick electrodes to minimize conductor loss. A single mask, self-aligned reverse-side exposure through the transparent substrate achieves both these goals. A single-finger test capacitor with an electrode gap of 1.2 µm and an electrode thickness of 2.2 µm is fabricated and characterized. Tunability (T = 100 × (C0 - Cbias)/C0) of 33% at 10 V has been achieved at 100 kHz. The 2.2 µm thick structure shows improvement of Q-factor compared to that of a 0.1 µm thick structure. To demonstrate the scalability of this process, a 102-finger interdigitated capacitor is fabricated and characterized at 100 kHz and 1 GHz. The structure is embedded in a 25 µm thick epoxy resin SU-8 for passivation. A quality factor decrease of 15-25%, tunability decrease of 2-3% and capacitance increase of 6% are observed due to the expoxy resin after passivation. High frequency performance of the capacitor has been measured to be 15.9 pF of capacitance, 28.1% tunability at 10 V and a quality factor of 16 (at a 10 V dc bias) at 1 GHz.

  9. Global maps of streamflow characteristics based on observations from several thousand catchments

    NASA Astrophysics Data System (ADS)

    Beck, Hylke; de Roo, Ad; van Dijk, Albert

    2016-04-01

    Streamflow (Q) estimation in ungauged catchments is one of the greatest challenges facing hydrologists. Observed Q from three to four thousand small-to-medium sized catchments (10--10 000~km^2) around the globe were used to train neural network ensembles to estimate Q characteristics based on climate and physiographic characteristics of the catchments. In total 17 Q characteristics were selected, including mean annual Q, baseflow index, and a number of flow percentiles. Testing coefficients of determination for the estimation of the Q characteristics ranged from 0.55 for the baseflow recession constant to 0.93 for the Q timing. Overall, climate indices dominated among the predictors. Predictors related to soils and geology were relatively unimportant, perhaps due to their data quality. The trained neural network ensembles were subsequently applied spatially over the entire ice-free land surface, resulting in global maps of the Q characteristics (0.125° resolution). These maps possess several unique features: they represent observation-driven estimates; are based on an unprecedentedly large set of catchments; and have associated uncertainty estimates. The maps can be used for various hydrological applications, including the diagnosis of macro-scale hydrological models. To demonstrate this, the produced maps were compared to equivalent maps derived from the simulated daily Q of four macro-scale hydrological models, highlighting various opportunities for improvement in model Q behavior. The produced dataset is available via http://water.jrc.ec.europa.eu.

  10. Weak charge form factor and radius of 208Pb through parity violation in electron scattering

    DOE PAGES

    Horowitz, C. J.; Ahmed, Z.; Jen, C. -M.; ...

    2012-03-26

    We use distorted wave electron scattering calculations to extract the weak charge form factor F W(more » $$\\bar{q}$$), the weak charge radius R W, and the point neutron radius R n, of 208Pb from the PREX parity violating asymmetry measurement. The form factor is the Fourier transform of the weak charge density at the average momentum transfer $$\\bar{q}$$ = 0.475 fm -1. We find F W($$\\bar{q}$$) = 0.204 ± 0.028(exp) ± 0.001(model). We use the Helm model to infer the weak radius from F W($$\\bar{q}$$). We find RW = 5.826 ± 0.181(exp) ± 0.027(model) fm. Here the exp error includes PREX statistical and systematic errors, while the model error describes the uncertainty in R W from uncertainties in the surface thickness σ of the weak charge density. The weak radius is larger than the charge radius, implying a 'weak charge skin' where the surface region is relatively enriched in weak charges compared to (electromagnetic) charges. We extract the point neutron radius R n = 5.751 ± 0.175 (exp) ± 0.026(model) ± 0.005(strange) fm, from R W. Here there is only a very small error (strange) from possible strange quark contributions. We find R n to be slightly smaller than R W because of the nucleon's size. As a result, we find a neutron skin thickness of R n-R p = 0.302 ± 0.175 (exp) ± 0.026 (model) ± 0.005 (strange) fm, where R p is the point proton radius.« less

  11. Experimental and theoretical investigations of the quality factor for n+p silicon solar cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garlick, G.F.J.; Kachare, A.H.

    1980-01-01

    Many N/sup +/P silicon cells made with silicon from different growth techniques have current-voltage relations of the form: I.I/sub 0/ (exp(qV/AkT) - 1) where the quality factor A is non-integral, is >1 and shows a temperature dependence. The dark forward characteristics of such cells have been measured over a range of temperature and the behavior of the factor A derived from them. A new model is presented on the assumption of non-uniform distributions of recombination levels in the junction depletion layer. This model shows good agreement with experimental data. The cells investigated had evaporated top metallization and so the junctionmore » contamination giving the recombination levels is likely to be a result of junction diffusion and is not specific to the metallization processing. The model needs further development and evaluation in order to apply it to the illuminated cell behavior and also to include any effects of distributed sheet resistance in the N/sup +/ layer. 17 refs.« less

  12. Microstrip resonators for electron paramagnetic resonance experiments

    NASA Astrophysics Data System (ADS)

    Torrezan, A. C.; Mayer Alegre, T. P.; Medeiros-Ribeiro, G.

    2009-07-01

    In this article we evaluate the performance of an electron paramagnetic resonance (EPR) setup using a microstrip resonator (MR). The design and characterization of the resonator are described and parameters of importance to EPR and spin manipulation are examined, including cavity quality factor, filling factor, and microwave magnetic field in the sample region. Simulated microwave electric and magnetic field distributions in the resonator are also presented and compared with qualitative measurements of the field distribution obtained by a perturbation technique. Based on EPR experiments carried out with a standard marker at room temperature and a MR resonating at 8.17 GHz, the minimum detectable number of spins was found to be 5×1010 spins/GHz1/2 despite the low MR unloaded quality factor Q0=60. The functionality of the EPR setup was further evaluated at low temperature, where the spin resonance of Cr dopants present in a GaAs wafer was detected at 2.3 K. The design and characterization of a more versatile MR targeting an improved EPR sensitivity and featuring an integrated biasing circuit for the study of samples that require an electrical contact are also discussed.

  13. Development of phage/antibody immobilized magnetostrictive biosensors

    NASA Astrophysics Data System (ADS)

    Fu, Liling

    There is an urgent need for biosensors that are able to detect and quantify the presence of a small amount of pathogens in a real-time manner accurately and quickly to guide prevention efforts and assay food and water quality. Acoustic wave (AW) devices, whose performance is defined by mass sensitivity (Sm) and quality factor (Q value), have been extensively studied as high performance biosensor platforms. However, current AW devices still face some challenges such as the difficulty to be employed in liquid and low Q value in practical applications. The objective of this research is to develop magnetostrictive sensors which include milli/microcantilever type (MSMC) and particle type (MSP). Compared to other AW devices, MSMC exhibits the following advantages: (1) wireless/remote driving and sensing; (2) easy to fabricate; (3) works well in liquid; (4) exhibits a high Q value (> 500 in air). The fundamental study of the damping effect on MSMCs from the surrounding media including air and liquids were conducted to improve the Q value of MSMCs. The experiment results show that the Q value is dependent on the properties of surrounding media (e.g. viscosity, density), the geometry of the MSMCs, and the harmonic mode on the resonance behavior of MSMCs, etc. The phage-coated MSMC has high specificity and sensitivity even while used in water with a low concentration of targeted bacteria. Two currently developed phages, JRB7 and E2, respectively respond to Bacillus anthracis spores and Salmonella typhimurium, were employed as bio-recognition elements in this research. The phage-immobilized MSMC biosensors exhibited high performance and detection of limit was 5 x 104 cfu/ml for the MSMC in size of 1.4 x 0.8 x 0.035 mm. The MSMC-based biosensors were indicated as a very potential method for in-situ monitoring of the biological quality in water. The MSP combine antibody was used to detect Staphylococcus aureus in this experiment. The interface between MSPs and antibody was modified using Traut's Reagent by introducing the sulfhydryl group. To improve the mass sensitivity of magnetostrictive biosensors, several blocking agents were used to resist the nonspecific adsorption of S. aureus on the surface of the magnetostrictive biosensors and the blocking effects were studied by using ELISA and SEM. The results showed casein was one of the best blocking agents to resist the nonspecific binding in this experiment. Casein blocked antibody immobilized MSP biosensors exhibited high sensitivity and the limit of detection is 102 cfu/ml.

  14. Lifelong Exercise Patterns and Cardiovascular Health.

    PubMed

    Maessen, Martijn F H; Verbeek, André L M; Bakker, Esmée A; Thompson, Paul D; Hopman, Maria T E; Eijsvogels, Thijs M H

    2016-06-01

    To determine the relationship between lifelong exercise dose and the prevalence of cardiovascular morbidity. From June 1, 2011, through December 31, 2014, 21,266 individuals completed an online questionnaire regarding their lifelong exercise patterns and cardiovascular health status. Cardiovascular disease (CVD) was defined as a diagnosis of myocardial infarction, stroke, or heart failure, and cardiovascular risk factors (CVRFs) were defined as hypertension, hypercholesterolemia, or type 2 diabetes. Lifelong exercise patterns were measured over a median of 32 years for 405 patients with CVD, 1379 patients with CVRFs, and 10,656 controls. Participants were categorized into nonexercisers and quintiles (Q1-Q5) of exercise dose (metabolic equivalent task [MET] minutes per week). The CVD/CVRF prevalence was lower for each exercise quintile compared with nonexercisers (CVD: nonexercisers, 9.6% vs Q1: 4.4%, Q2: 2.8%, Q3: 2.4%, Q4: 3.6%, Q5: 3.9%; P<.001; CVRF: nonexercisers, 24.6% vs Q1: 13.8%, Q2: 10.2%, Q3: 9.0%, Q4: 9.4%, Q5: 12.0%; P<.001). The lowest exercise dose (Q1) significantly reduced CVD and CVRF prevalence, but the largest reductions were found at 764 to 1091 MET-min/wk for CVD (adjusted odds ratio=0.31; 95% CI, 0.20-0.48) and CVRFs (adjusted odds ratio=0.36; 95% CI, 0.28-0.47). The CVD/CVRF prevalence did not further decrease in higher exercise dose groups. Exercise intensity did not influence the relationship between exercise patterns and CVD or CVRFs. These findings demonstrate a curvilinear relationship between lifelong exercise patterns and cardiovascular morbidity. Low exercise doses can effectively reduce CVD/CVRF prevalence, but engagement in exercise for 764 to 1091 MET-min/wk is associated with the lowest CVD/CVRF prevalence. Higher exercise doses do not yield additional benefits. Copyright © 2016 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  15. Prospective study of DNA methylation at chromosome 8q24 in peripheral blood and prostate cancer risk.

    PubMed

    Barry, Kathryn Hughes; Moore, Lee E; Sampson, Joshua N; Koutros, Stella; Yan, Liying; Meyer, Ann; Reddy, Mahitha; Oler, Andrew J; Cook, Michael B; Fraumeni, Joseph F; Yeager, Meredith; Amundadottir, Laufey T; Berndt, Sonja I

    2017-05-23

    Chromosome 8q24 has emerged as an important genetic susceptibility region for several cancers, including prostate cancer; however, little is known about the contribution of DNA methylation in this region to risk. We prospectively evaluated DNA methylation at 8q24 in relation to prostate cancer using pre-diagnostic blood samples from 694 prostate cancer cases (including 172 aggressive cases) and 703 controls in the Prostate, Lung, Colorectal and Ovarian Cancer Screening Trial. We used logistic regression to estimate odds ratios and 95% confidence intervals. Although none remained significant after adjustment for multiple testing (q>0.05), of the 50 CpG sites meeting quality control, we identified 8 sites that were nominally associated with prostate cancer (P trend <0.05), including 6 correlated (Spearman ρ: 0.20-0.52) sites in POU5F1B and 2 intergenic sites (most significant site: Chr8:128428897 in POU5F1B, P trend =0.01). We also identified two correlated (ρ=0.39) sites in MYC (Chr8:128753187 and Chr8:128753154) that were associated with aggressive (P trend =0.02 and 0.03), but not non-aggressive disease (P trend =0.70 and 0.20; P heterogeneity =0.01 and 4.6 × 10 -3 ). These findings persisted after adjustment for the top 8q24 prostate cancer variants in our study. Although requiring replication, our findings provide some evidence that 8q24 DNA methylation levels may be associated with prostate cancer risk.

  16. Efficient expulsion of magnetic flux in superconducting radiofrequency cavities for high Q 0 applications

    DOE PAGES

    Posen, S.; Checchin, M.; Crawford, A. C.; ...

    2016-06-03

    Even when cooled through its transition temperature in the presence of an external magnetic field, a superconductor can expel nearly all external magnetic flux. This Letter presents an experimental study to identify the parameters that most strongly influence flux trapping in high purity niobium during cooldown. This is critical to the operation of superconducting radiofrequency cavities, in which trapped flux degrades the quality factor and therefore cryogenic efficiency. Flux expulsion was measured on a large survey of 1.3 GHz cavities prepared in various ways. It is shown that both spatial thermal gradient and high temperature treatment are critical to expellingmore » external magnetic fields, while surface treatment has minimal effect. For the first time, it is shown that a cavity can be converted from poor expulsion behavior to strong expulsion behavior after furnace treatment, resulting in a substantial improvement in quality factor. In conclusion, future plans are described to build on this result in order to optimize treatment for future cavities.« less

  17. Degradation diagnosis of lithium-ion batteries with a LiNi0.5Co0.2Mn0.3O2 and LiMn2O4 blended cathode using dV/dQ curve analysis

    NASA Astrophysics Data System (ADS)

    Ando, Keisuke; Matsuda, Tomoyuki; Imamura, Daichi

    2018-06-01

    Understanding the degradation factors (cathode and anode degradation and solid electrolyte interface (SEI) formation) of lithium-ion batteries (LIBs) with a blended cathode is necessary to improve their durability because battery drive vehicles often use LIBs with a blended cathode due to advantages of power and cost. We developed a dV/dQ curve analysis adapted for through a dQ/dV curve analysis to elucidate the relations between cycle test conditions and degradation factors. To compare said factors, cycle tests were conducted under different conditions: one charge/discharge rate (C/3), two state-of-charge (SoC) ranges (100%-0% and 100%-70%), and three temperatures (0 °C, 25 °C, and 45 °C). We confirmed that there are clear differences in the degree of contribution of each degradation factor depending on conditions. For instance, at 0 °C, although the capacity reduction rate was almost the same regardless of the SoC range, the degradation mechanisms were different, i.e., the cathode degradation and the SEI formation occurred at the same time, resulting in the reduced capacity for the 100%-0% SoC range, while capacity reduction was mainly due to SEI formation for the 100%-70% SoC range.

  18. Frequency stability of maser oscillators operated with cavity Q. [hydrogen and rubidium masers

    NASA Technical Reports Server (NTRS)

    Tetu, M.; Tremblay, P.; Lesage, P.; Petit, P.; Audoin, C.

    1982-01-01

    The short term frequency stability of masers equipped with an external feedback loop to increase the cavity quality factor was studied. The frequency stability of a hydrogen and a rubidium maser were measured and compared with theoretical evaluation. It is shown that the frequency stability passes through an optimum when the cavity Q is varied. Long term fluctuations are discussed and the optimum mid term frequency stability achievably by small size active and passive H-masers is considered.

  19. Coenzyme Q10 and pro-inflammatory markers in children with Down syndrome: clinical and biochemical aspects.

    PubMed

    Zaki, Moushira E; El-Bassyouni, Hala T; Tosson, Angie M S; Youness, Eman; Hussein, Jihan

    Evidence of oxidative stress was reported in individuals with Down syndrome. There is a growing interest in the contribution of the immune system in Down syndrome. The aim of this study is to evaluate the coenzyme Q10 and selected pro-inflammatory markers such as interleukin 6 and tumor necrosis factor α in children with Down syndrome. Eighty-six children (5-8 years of age) were enrolled in this case-control study from two public institutions. At the time of sampling, the patients and controls suffered from no acute or chronic illnesses and received no therapies or supplements. The levels of interleukin 6, tumor necrosis factor α, coenzyme Q10, fasting blood glucose, and intelligence quotient were measured. Forty-three young Down syndrome children and forty-three controls were included over a period of eight months (January-August 2014). Compared with the control group, the Down syndrome patients showed significant increase in interleukin 6 and tumor necrosis factor α (p=0.002), while coenzyme Q10 was significantly decreased (p=0.002). Also, body mass index and fasting blood glucose were significantly increased in patients. There was a significantly positive correlation between coenzyme Q10 and intelligence quotient levels, as well as between interleukin 6 and tumor necrosis factor α. Interleukin 6 and tumor necrosis factor α levels in young children with Down syndrome may be used as biomarkers reflecting the neurodegenerative process in them. Coenzyme Q10 might have a role as a good supplement in young children with Down syndrome to ameliorate the neurological symptoms. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  20. Analysis and optimization of acoustic wave micro-resonators integrating piezoelectric zinc oxide layers

    NASA Astrophysics Data System (ADS)

    Mortada, O.; Zahr, A. H.; Orlianges, J.-C.; Crunteanu, A.; Chatras, M.; Blondy, P.

    2017-02-01

    This paper reports on the design, simulation, fabrication, and test results of ZnO-based contour-mode micro-resonators integrating piezoelectric zinc oxide (ZnO) layers. The inter-digitated (IDT) type micro-resonators are fabricated on ZnO films and suspended top of 2 μm thick silicon membranes using silicon-on insulator technology. We analyze several possibilities of increasing the quality factor (Q) and the electromechanical coupling coefficient (kt2) of the devices by varying the numbers and lengths of the IDT electrodes and using different thicknesses of the ZnO layer. We designed and fabricated IDTs of different finger numbers (n = 25, 40, 50, and 80) and lengths (L = 100/130/170/200 μm) for three different thicknesses of ZnO films (200, 600, and 800 nm). The measured Q factor confirms that reducing the length and the number of IDT fingers enables us to reach better electrical performances at resonant frequencies around 700 MHz. The extracted results for an optimized micro-resonator device having an IDT length of 100 μm and 40 finger electrodes show a Q of 1180 and a kt2 of 7.4%. We demonstrate also that the reduction of the ZnO thickness from 800 nm to 200 nm increases the quality factor from 430 to 1600, respectively, around 700 MHz. Experimental data are in very good agreement with theoretical simulations of the fabricated devices

  1. Can online networks provide quality answers to questions about occupational safety and health?

    PubMed

    Rhebergen, Martijn D F; Lenderink, Annet F; van Dijk, Frank J H; Hulshof, Carel T J

    2012-05-01

    To assess whether experts can provide high-quality answers to occupational safety and health (OSH) questions in online Question & Answer (Q&A) networks. The authors evaluated the quality of answers provided by qualified experts in two Dutch online networks: ArboAntwoord and the Helpdesk of the Netherlands Center for Occupational Diseases. A random sample of 594 answers was independently evaluated by two raters using nine answer quality criteria. An additional criterion, the agreement of answers with the best available evidence, was explored by peer review of a sample of 42 answers. Reviewers performed an evidence search in Medline. The median answer quality score of ArboAntwoord (N=295) and the Netherlands Center for Occupational Diseases Helpdesk (N=299) was 8 of 9 (IQR 2). The inter-rater reliability of the first nine quality criteria was high (κ 0.82-0.90, p<0.05). A question answered by two or more experts had a greater probability of a high-quality score than questions answered by one expert (OR 4.9, 95% CI 2.7 to 9.0). Answers most often scored insufficient on the use of evidence to underpin the answer (36% and 38% for the networks, respectively) and on conciseness (35% and 31%, respectively). Peer review demonstrated that 43%-72% of the answers in both online networks were in complete agreement with the best available evidence. OSH experts are able to provide quality answers in online OSH Q&A networks. Our answer quality appraisal instrument was feasible and provided information on how to improve answer quality.

  2. Measurement of the generalized form factors near threshold via γ*p→nπ+ at high Q2

    NASA Astrophysics Data System (ADS)

    Park, K.; Gothe, R. W.; Adhikari, K. P.; Adikaram, D.; Anghinolfi, M.; Baghdasaryan, H.; Ball, J.; Battaglieri, M.; Batourine, V.; Bedlinskiy, I.; Bennett, R. P.; Biselli, A. S.; Bookwalter, C.; Boiarinov, S.; Branford, D.; Briscoe, W. J.; Brooks, W. K.; Burkert, V. D.; Carman, D. S.; Celentano, A.; Chandavar, S.; Charles, G.; Cole, P. L.; Contalbrigo, M.; Crede, V.; D'Angelo, A.; Daniel, A.; Dashyan, N.; De Vita, R.; De Sanctis, E.; Deur, A.; Djalali, C.; Doughty, D.; Dupre, R.; El Alaoui, A.; El Fassi, L.; Eugenio, P.; Fedotov, G.; Fradi, A.; Gabrielyan, M. Y.; Gevorgyan, N.; Gilfoyle, G. P.; Giovanetti, K. L.; Girod, F. X.; Goetz, J. T.; Gohn, W.; Golovatch, E.; Graham, L.; Griffioen, K. A.; Guidal, M.; Guo, L.; Hafidi, K.; Hakobyan, H.; Hanretty, C.; Heddle, D.; Hicks, K.; Holtrop, M.; Hyde, C. E.; Ilieva, Y.; Ireland, D. G.; Ishkhanov, B. S.; Isupov, E. L.; Jenkins, D.; Jo, H. S.; Joo, K.; Kalantarians, N.; Khandaker, M.; Khetarpal, P.; Kim, A.; Kim, W.; Klein, A.; Klein, F. J.; Kubarovsky, A.; Kubarovsky, V.; Kuhn, S. E.; Kuleshov, S. V.; Kvaltine, N. D.; Livingston, K.; Lu, H. Y.; MacGregor, I. J. D.; Markov, N.; Mayer, M.; McKinnon, B.; Mestayer, M. D.; Meyer, C. A.; Mineeva, T.; Mirazita, M.; Mokeev, V.; Moutarde, H.; Munevar, E.; Nadel-Turonski, P.; Nasseripour, R.; Niccolai, S.; Niculescu, G.; Niculescu, I.; Osipenko, M.; Ostrovidov, A. I.; Paolone, M.; Pappalardo, L.; Paremuzyan, R.; Park, S.; Pereira, S. Anefalos; Phelps, E.; Pisano, S.; Pogorelko, O.; Pozdniakov, S.; Price, J. W.; Procureur, S.; Prok, Y.; Ricco, G.; Rimal, D.; Ripani, M.; Ritchie, B. G.; Rosner, G.; Rossi, P.; Sabatié, F.; Saini, M. S.; Salgado, C.; Schott, D.; Schumacher, R. A.; Seraydaryan, H.; Sharabian, Y. G.; Smith, E. S.; Smith, G. D.; Sober, D. I.; Sokhan, D.; Stepanyan, S. S.; Stepanyan, S.; Stoler, P.; Strakovsky, I. I.; Strauch, S.; Taiuti, M.; Tang, W.; Taylor, C. E.; Tian, Y.; Tkachenko, S.; Trivedi, A.; Ungaro, M.; Vernarsky, B.; Vlassov, A. V.; Voutier, E.; Watts, D. P.; Weygand, D. P.; Wood, M. H.; Zachariou, N.; Zhao, B.; Zhao, Z. W.

    2012-03-01

    We report the first extraction of the pion-nucleon multipoles near the production threshold for the nπ+ channel at relatively high momentum transfer (Q2 up to 4.2 GeV2). The dominance of the s-wave transverse multipole (E0+), expected in this region, allowed us to access the generalized form factor G1 within the light-cone sum-rule (LCSR) framework as well as the axial form factor GA. The data analyzed in this work were collected by the nearly 4π CEBAF Large Acceptance Spectrometer (CLAS) using a 5.754-GeV electron beam on a proton target. The differential cross section and the π-N multipole E0+/GD were measured using two different methods, the LCSR and a direct multipole fit. The results from the two methods are found to be consistent and almost Q2 independent.

  3. A quantitative theory of the Hounsfield unit and its application to dual energy scanning.

    PubMed

    Brooks, R A

    1977-10-01

    A standard definition is proposed for the Hounsfield number. Any number in computed tomography can be converted to the Hounsfield scale after performing a simple calibration using air and water. The energy dependence of the Hounsfield number, H, is given by the expression H = (Hc + Hp Q)/(1 + Q), where Hc and Hp are the Compton and photoelectric coefficients of the material being measured, expressed in Hounsfield units, and Q is the "quality factor" of the scanner. Q can be measured by performing a scan of a single calibrating material, such as a potassium iodine solution. By applying this analysis to dual energy scans, the Compton and photoelectric coefficients of an unknown substance may easily be obtained. This can lead to a limited degree of chemical identification.

  4. Ionization chamber-based reference dosimetry of intensity modulated radiation beams.

    PubMed

    Bouchard, Hugo; Seuntjens, Jan

    2004-09-01

    The present paper addresses reference dose measurements using thimble ionization chambers for quality assurance in IMRT fields. In these radiation fields, detector fluence perturbation effects invalidate the application of open-field dosimetry protocol data for the derivation of absorbed dose to water from ionization chamber measurements. We define a correction factor C(Q)IMRT to correct the absorbed dose to water calibration coefficient N(D, w)Q for fluence perturbation effects in individual segments of an IMRT delivery and developed a calculation method to evaluate the factor. The method consists of precalculating, using accurate Monte Carlo techniques, ionization chamber, type-dependent cavity air dose, and in-phantom dose to water at the reference point for zero-width pencil beams as a function of position of the pencil beams impinging on the phantom surface. These precalculated kernels are convolved with the IMRT fluence distribution to arrive at the dose-to-water-dose-to-cavity air ratio [D(a)w (IMRT)] for IMRT fields and with a 10x10 cm2 open-field fluence to arrive at the same ratio D(a)w (Q) for the 10x10 cm2 reference field. The correction factor C(Q)IMRT is then calculated as the ratio of D(a)w (IMRT) and D(a)w (Q). The calculation method was experimentally validated and the magnitude of chamber correction factors in reference dose measurements in single static and dynamic IMRT fields was studied. The results show that, for thimble-type ionization chambers the correction factor in a single, realistic dynamic IMRT field can be of the order of 10% or more. We therefore propose that for accurate reference dosimetry of complete n-beam IMRT deliveries, ionization chamber fluence perturbation correction factors must explicitly be taken into account.

  5. Nursing home staff members' subjective frames of reference on residents' achievement of ego integrity: A Q-methodology study.

    PubMed

    Lim, Sun-Young; Chang, Sung-Ok

    2018-01-01

    To discover the structure of the frames of reference for nursing home staff members' subjective judgment of residents' achievement of ego integrity. Q-methodology was applied. Twenty-eight staff members who were working in a nursing home sorted 34 Q-statements into the shape of a normal distribution. A centroid factor analysis and varimax rotation, using the PQ-method program, revealed four factors: identifying clues to residents' positive acceptance of their whole life span, identifying residents' ways of enjoying their current life, referencing residents' attitudes and competencies toward harmonious relationships, and identifying residents' integrated efforts to establish self-esteem. These subjective frames of reference need to be investigated in order to improve the relationships with nursing home residents and their quality of life. Consequently, the fundamental monitoring tools to help staff members make subjective judgments can be formed. © 2017 Japan Academy of Nursing Science.

  6. Packaged microsphere-taper coupling system with a high Q factor.

    PubMed

    Dong, Yongchao; Wang, Keyi; Jin, Xueying

    2015-01-10

    A novel packaged microsphere-taper coupling system which consists of a glass tube and two glass plates is proposed and demonstrated in this paper. We analyze the impact of the microsphere distortion on the resonant spectrum and it is observed that a very high quality factor (Q) up to 1.08×10(8) can be achieved by optimizing the microsphere position and orientation relative to the fiber taper. The maintenance of Q and a stable spectrum are realized by placing the packaged structure in a sealed organic glass box. Furthermore, to verify the practicability of the sealed device, thermal sensing experiments are carried out, which indicates the excellent convenience of the device with a resolution of 1.12×10(-4)°C. The portability and robustness of the packaged structure make it strikingly attractive and illustrate its potential in practical microcavity sensors and lasers.

  7. Treating Small Bowel Obstruction with a Manual Physical Therapy: A Prospective Efficacy Study

    PubMed Central

    Rice, Amanda D.; Patterson, Kimberley; Reed, Evette D.; Wurn, Belinda F.; Klingenberg, Bernhard; King, C. Richard; Wurn, Lawrence J.

    2016-01-01

    Small bowel obstructions (SBOs) caused by adhesions are a common, often life-threatening postsurgical complication with few treatment options available for patients. This study examines the efficacy of a manual physical therapy treatment regimen on the pain and quality of life of subjects with a history of bowel obstructions due to adhesions in a prospective, controlled survey based study. Changes in six domains of quality of life were measured via ratings reported before and after treatment using the validated Small Bowel Obstruction Questionnaire (SBO-Q). Improvements in the domains for pain (p = 0.0087), overall quality of life (p = 0.0016), and pain severity (p = 0.0006) were significant when average scores before treatment were compared with scores after treatment. The gastrointestinal symptoms (p = 0.0258) domain was marginally significant. There was no statistically significant improvement identified in the diet or medication domains in the SBO-Q for this population. Significant improvements in range of motion in the trunk (p ≤ 0.001), often limited by adhesions, were also observed for all measures. This study demonstrates in a small number of subjects that this manual physical therapy protocol is an effective treatment option for patients with adhesive small bowel obstructions as measured by subject reported symptoms and quality of life. PMID:26989690

  8. Adaptation of the Nomophobia Questionnaire (NMP-Q) to Spanish in a sample of adolescents.

    PubMed

    González-Cabrera, Joaquín; León-Mejía, Ana; Pérez-Sancho, Carlota; Calvete, Esther

    2017-07-01

    Nomophobia is the fear of being out of mobile phone contact. People suffering from this anxiety disorder have feelings of stress and nervousness when access to their mobiles or computers is not possible. This work is an adaptation and validation study of the Spanish version of the Nomophobia Questionnaire (NMP-Q). The study included 306 students (46.1% males and 53.9% females) with ages ranging 13 to 19 years (Md=15.41±1.22). Exploratory factor analysis revealed four dimensions that accounted for 64.4% of total variance. The ordinal α-value was 0.95, ranging from 0.75 to 0.92 across factors. Measure of stability was calculated by the testretest method (r=0.823). Indicators of convergence with the Spanish versions of the “Mobile Phone Problem Use Scale” (r=0.654) and the “Generalized Problematic Internet Use Scale” (r=0.531) were identified. Problematic mobile phone use patterns were examined taking the 15P, 80P and 95P percentiles as cut-off points. Scores of 39, 87 and 116 on NMP-Q corresponded to occasional, at-risk and problematic users, respectively. Psychometric analysis shows that the Spanish version of the NMP-Q is a valid and reliable tool for the study of nomophobia.

  9. Differential Decay of Cattle-associated Fecal Indicator ...

    EPA Pesticide Factsheets

    Background: Fecal indicator bacteria (FIB) have a long history of use in the assessment of the microbial quality of recreational waters. However, quantification of FIB provides no information about the pollution source(s) and relatively little is known about their fate in the ambient waters. Microbial source tracking (MST) field has evolved in response to a need to identify pollution source(s), but majority of MST markers suffer from the same caveat as FIB, as our understanding of the factors influencing their fate in the environment is limited. Materials: We assessed the effect of water type (freshwater vs marine) and select environmental parameters (indigenous microbiota, ambient sunlight) on decay of FIB and MST markers from cattle manure. Experiments were conducted in situ using a submersible aquatic mesocosm containing dialysis bags filled with mixture of cattle manure and ambient water. Culturable FIB were enumerated by membrane filtration and via qPCR (Entero1a, EC23S) and MST markers were enumerated via qPCR and included general marker of fecal pollution (GenBac3) and cattle-associated subset (Rum2Bac, CowM2, CowM3). Results: Decay of culturable FIB was significantly faster (P > 0.001) than any of the molecular markers irrespective of the water type or experimental conditions. The water type was a significant factor affecting decay (P: 0.008 to < 0.001), although the magnitude of the effect differed among the microbial targets and over time. Presence o

  10. Improvement in Self-reported Quality of Life with Cognitive Therapy for Recurrent Major Depressive Disorder

    PubMed Central

    Jha, Manish Kumar; Minhajuddin, Abu; Thase, Michael E.; Jarrett, Robin B.

    2014-01-01

    Background Major Depressive Disorder is common, often recurrent and/or chronic. Theoretically, assessing quality of life (QoL) in addition to the current practice of assessing depressive symptoms has the potential to offer a more comprehensive evaluation of the effects of treatment interventions and course of illness. Methods Before and after acute-phase cognitive therapy (CT), 492 patients from Continuation Phase Cognitive Therapy Relapse Prevention trial (Jarrett et al., 2013, Jarrett and Thase, 2010) completed the Quality of Life Enjoyment and Satisfaction Questionnaire (Q-LES-Q), Inventory of Depressive Symptomatology Self-report (IDS-SR) & Beck Depression Inventory (BDI); clinicians completed Hamilton Rating Scale for Depression-17-items. Repeated measures analysis of variance evaluated the improvement in QoL before/after CT and measured the effect sizes. Change analyses to assess clinical significance (Hageman and Arrindell, 1999) were conducted. Results At the end of acute-phase CT, a repeated measure analysis of variance produced a statistically significant increase in Q-LES-Q scores with effect sizes of 0.48 - 1.3; 76.9 - 91.4% patients reported clinically significant improvement. Yet, only 11 - 38.2% QoL scores normalized. An analysis of covariance showed that change in depression severity (covariates=IDS-SR, BDI) completely accounted for the improvement in Q-LES-Q scores. Limitations There were only two time points of observation; clinically significant change analyses lacked matched normal controls; and generalizability is constrained by sampling characteristics. Conclusions: Quality of life improves significantly in patients with recurrent MDD after CT; however, this improvement is completely accounted for by change in depression severity. Normalization of QoL in all patients may require targeted, additional, and/or longer treatment. PMID:25082112

  11. Improvement in self-reported quality of life with cognitive therapy for recurrent major depressive disorder.

    PubMed

    Jha, Manish Kumar; Minhajuddin, Abu; Thase, Michael E; Jarrett, Robin B

    2014-01-01

    Major depressive disorder (MDD) is common, often recurrent and/or chronic. Theoretically, assessing quality of life (QoL) in addition to the current practice of assessing depressive symptoms has the potential to offer a more comprehensive evaluation of the effects of treatment interventions and course of illness. Before and after acute-phase cognitive therapy (CT), 492 patients from Continuation Phase Cognitive Therapy Relapse Prevention trial (Jarrett et al., 2013; Jarrett and Thase, 2010) completed the Quality of Life Enjoyment and Satisfaction Questionnaire (Q-LES-Q), Inventory of Depressive Symptomatology Self-report (IDS-SR) and Beck Depression Inventory (BDI); clinicians completed Hamilton Rating Scale for Depression-17-items. Repeated measures analysis of variance evaluated the improvement in QoL before/after CT and measured the effect sizes. Change analyses to assess clinical significance (Hageman and Arrindell, 1999) were conducted. At the end of acute-phase CT, a repeated measure analysis of variance produced a statistically significant increase in Q-LES-Q scores with effect sizes of 0.48-1.3%; 76.9-91.4% patients reported clinically significant improvement. Yet, only 11-38.2% QoL scores normalized. An analysis of covariance showed that change in depression severity (covariates=IDS-SR, BDI) completely accounted for the improvement in Q-LES-Q scores. There were only two time points of observation; clinically significant change analyses lacked matched normal controls; and generalizability is constrained by sampling characteristics. Quality of life improves significantly in patients with recurrent MDD after CT; however, this improvement is completely accounted for by change in depression severity. Normalization of QoL in all patients may require targeted, additional, and/or longer treatment. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Proof-of-principle demonstration of Nb3Sn superconducting radiofrequency cavities for high Q0 applications

    NASA Astrophysics Data System (ADS)

    Posen, S.; Liepe, M.; Hall, D. L.

    2015-02-01

    Many future particle accelerators require hundreds of superconducting radiofrequency (SRF) cavities operating with high duty factor. The large dynamic heat load of the cavities causes the cryogenic plant to make up a significant part of the overall cost of the facility. This contribution can be reduced by replacing standard niobium cavities with ones coated with a low-dissipation superconductor such as Nb3Sn. In this paper, we present results for single cell cavities coated with Nb3Sn at Cornell. Five coatings were carried out, showing that at 4.2 K, high Q0 out to medium fields was reproducible, resulting in an average quench field of 14 MV/m and an average 4.2 K Q0 at quench of 8 × 109. In each case, the peak surface magnetic field at quench was well above Hc1, showing that it is not a limiting field in these cavities. The coating with the best performance had a quench field of 17 MV/m, exceeding gradient requirements for state-of-the-art high duty factor SRF accelerators. It is also shown that—taking into account the thermodynamic efficiency of the cryogenic plant—the 4.2 K Q0 values obtained meet the AC power consumption requirements of state-of-the-art high duty factor accelerators, making this a proof-of-principle demonstration for Nb3Sn cavities in future applications.

  13. Neck Circumference and Incidence of Diabetes Mellitus over 10 Years in the Korean Genome and Epidemiology Study (KoGES)

    PubMed Central

    Cho, Nam H.; Oh, Tae Jung; Kim, Kyoung Min; Choi, Sung Hee; Lee, Jae Ho; Park, Kyong Soo; Jang, Hak Chul; Kim, Jong Yeol; Lee, Hong Kyu; Lim, Soo

    2015-01-01

    Neck circumference, a proxy for upper-body fat, may be a unique fat depot that indicates metabolic risk beyond whole body fat. We investigated whether neck circumference is associated with development of diabetes mellitus (DM) in a subset of data with Korean Genome and Epidemiology Study (n = 3521, age range = 42–71 years). Nondiabetic subjects at the baseline were categorized into 4 groups (Q1–Q4) according to their neck circumference. Parameters related with β-cell function and insulin resistance including Epworth sleepiness scale and snoring habit were examined. The development of DM was confirmed biannually based on a 75-g oral glucose tolerance test. Over the 10 years, 2623 (74.5%) among 3521 subjects were followed-up. Among them, 632 (24.1%) developed DM. The incidence of DM increased from 17.6% in Q1 to 18.2% in Q2, to 25.4% in Q3, and to 36.0% in Q4 (P < 0.001). After adjusting for most risk factors related with DM, the relative risks of DM development were 0.989 (95% confidence interval, 0.638–1.578), 1.660 (1.025–2.687), and 1.746 (1.037–2.942) in men and 0.939 (0.540–1.769), 1.518 (0.808–2.853), and 2.077 (1.068–4.038) in women in Q2, Q3, and Q4, respectively when compared to Q1. This finding indicates negative impact from large neck circumference in the development of DM. PMID:26681338

  14. Association of the Quick Sequential (Sepsis-Related) Organ Failure Assessment (qSOFA) Score With Excess Hospital Mortality in Adults With Suspected Infection in Low- and Middle-Income Countries.

    PubMed

    Rudd, Kristina E; Seymour, Christopher W; Aluisio, Adam R; Augustin, Marc E; Bagenda, Danstan S; Beane, Abi; Byiringiro, Jean Claude; Chang, Chung-Chou H; Colas, L Nathalie; Day, Nicholas P J; De Silva, A Pubudu; Dondorp, Arjen M; Dünser, Martin W; Faiz, M Abul; Grant, Donald S; Haniffa, Rashan; Van Hao, Nguyen; Kennedy, Jason N; Levine, Adam C; Limmathurotsakul, Direk; Mohanty, Sanjib; Nosten, François; Papali, Alfred; Patterson, Andrew J; Schieffelin, John S; Shaffer, Jeffrey G; Thuy, Duong Bich; Thwaites, C Louise; Urayeneza, Olivier; White, Nicholas J; West, T Eoin; Angus, Derek C

    2018-05-20

    The quick Sequential (Sepsis-Related) Organ Failure Assessment (qSOFA) score has not been well-evaluated in low- and middle-income countries (LMICs). To assess the association of qSOFA with excess hospital death among patients with suspected infection in LMICs and to compare qSOFA with the systemic inflammatory response syndrome (SIRS) criteria. Retrospective secondary analysis of 8 cohort studies and 1 randomized clinical trial from 2003 to 2017. This study included 6569 hospitalized adults with suspected infection in emergency departments, inpatient wards, and intensive care units of 17 hospitals in 10 LMICs across sub-Saharan Africa, Asia, and the Americas. Low (0), moderate (1), or high (≥2) qSOFA score (range, 0 [best] to 3 [worst]) or SIRS criteria (range, 0 [best] to 4 [worst]) within 24 hours of presentation to study hospital. Predictive validity (measured as incremental hospital mortality beyond that predicted by baseline risk factors, as a marker of sepsis or analogous severe infectious course) of the qSOFA score (primary) and SIRS criteria (secondary). The cohorts were diverse in enrollment criteria, demographics (median ages, 29-54 years; males range, 36%-76%), HIV prevalence (range, 2%-43%), cause of infection, and hospital mortality (range, 1%-39%). Among 6218 patients with nonmissing outcome status in the combined cohort, 643 (10%) died. Compared with a low or moderate score, a high qSOFA score was associated with increased risk of death overall (19% vs 6%; difference, 13% [95% CI, 11%-14%]; odds ratio, 3.6 [95% CI, 3.0-4.2]) and across cohorts (P < .05 for 8 of 9 cohorts). Compared with a low qSOFA score, a moderate qSOFA score was also associated with increased risk of death overall (8% vs 3%; difference, 5% [95% CI, 4%-6%]; odds ratio, 2.8 [95% CI, 2.0-3.9]), but not in every cohort (P < .05 in 2 of 7 cohorts). High, vs low or moderate, SIRS criteria were associated with a smaller increase in risk of death overall (13% vs 8%; difference, 5% [95% CI, 3%-6%]; odds ratio, 1.7 [95% CI, 1.4-2.0]) and across cohorts (P < .05 for 4 of 9 cohorts). qSOFA discrimination (area under the receiver operating characteristic curve [AUROC], 0.70 [95% CI, 0.68-0.72]) was superior to that of both the baseline model (AUROC, 0.56 [95% CI, 0.53-0.58; P < .001) and SIRS (AUROC, 0.59 [95% CI, 0.57-0.62]; P < .001). When assessed among hospitalized adults with suspected infection in 9 LMIC cohorts, the qSOFA score identified infected patients at risk of death beyond that explained by baseline factors. However, the predictive validity varied among cohorts and settings, and further research is needed to better understand potential generalizability.

  15. Analysis of 3-chloro-4-(dichloromethyl)-5-hydroxy-2(5H)-furanone (MX) and its brominated analogues in chlorine-treated water by gas chromatography coupled to triple quadrupole tandem mass spectrometry (GC-QqQ-MS/MS).

    PubMed

    Planas, Carles; Ventura, Francesc; Caixach, Josep; Martín, Jordi; Boleda, M Rosa; Paraira, Miquel

    2015-11-01

    A simple, selective and sensitive method for the analysis of the strong mutagen 3-chloro-4-(dichloromethyl)-5-hydroxy-2(5H)-furanone (MX) and its brominated analogues (BMXs) in chlorine-treated water has been developed. The method is based on gas chromatography coupled to triple quadrupole tandem mass spectrometry (GC-QqQ-MS/MS), previous liquid-liquid extraction (LLE) of a smaller sample volume compared to other methods and on-line derivatization with a silylation reactive. GC-QqQ-MS/MS has been raised as an alternative easier to perform than gas chromatography coupled to high resolution mass spectrometry (GC-HRMS) for the analysis of MX and BMXs, and it allows to achieve low LODs (0.3 ng/L for MX and 0.4-0.9 ng/L for BMXs). This technique had not been previously described for the analysis of MX and BMXs. Quality parameters were calculated and real samples related to 3 drinking water treatment plants (DWTPs), tap water and both untreated and chlorinated groundwater were analyzed. Concentrations of 0.3-6.6 ng/L for MX and 1.0-7.3 ng/L for BMXs were detected. Results were discussed according to five of the main factors affecting MX and BMXs formation in chlorine-treated water (organic precursors, influence of bromide ions, evolution of MX and BMXs in the drinking water distribution system, groundwater chlorination and infiltration of water coming from chlorination processes in groundwater). Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Development and validation study of the Smartphone Overuse Screening Questionnaire.

    PubMed

    Lee, Han-Kyeong; Kim, Ji-Hae; Fava, Maurizio; Mischoulon, David; Park, Jae-Hyun; Shim, Eun-Jung; Lee, Eun-Ho; Lee, Ji Hyeon; Jeon, Hong Jin

    2017-11-01

    The aim of this study was to develop a screening questionnaire that could distinguish individuals at high risk of smartphone overuse from casual users. The reliability, validity, and diagnostic ability of the Smartphone Overuse Screening Questionnaire (SOS-Q) were evaluated. Preliminary items were assessed by 50 addiction experts on-line, and 28 questions were selected. A total of 158 subjects recruited from six community centers for internet addiction participated in this study. The SOS-Q, Young's internet addiction scale, Korean scale for internet addiction, and Smartphone Scale for Smartphone Addiction (S-Scale) were used to assess the concurrent validity. Construct validity was supported by a six-factor model using an exploratory factor analysis. The internal consistency and the item-total correlations were favorable (α = 0.95, r = 0.35-0.81). The test-retest reliability was moderate (r = 0.70). The SOS-Q showed superior concurrent validity with the highest correlation between the S-Scale (r = 0.76). Receiver operating characteristic curve analysis revealed an area under the curve of 0.877. A cut-off point of 49 effectively categorized addiction high-risk group with a sensitivity of 0.81 and specificity of 0.86. Overall, the current study supports the use of SOS-Q as both a primary and supplementary measurement tool in a variety of settings. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Cost-Effectiveness Analysis of Abatacept Compared with Adalimumab on Background Methotrexate in Biologic-Naive Adult Patients with Rheumatoid Arthritis and Poor Prognosis.

    PubMed

    Alemao, Evo; Johal, Sukhvinder; Al, Maiwenn J; Rutten-van Mölken, Maureen

    2018-02-01

    To assess cost effectiveness of abatacept versus adalimumab, each administered with methotrexate, in treating patients with rheumatoid arthritis (RA) stratified according to baseline anticitrullinated protein antibody (ACPA) levels (marker of poor prognosis in RA). A payer-perspective cost-effectiveness model simulated disease progression in patients with RA who had previously failed conventional disease-modifying antirheumatic drugs and were starting biologic therapy. Patients commenced treatment with abatacept or adalimumab plus methotrexate and were evaluated after 6 months. Therapy continuation was based on the European League Against Rheumatism treatment response; disease progression was based on the Health Assessment Questionnaire Disability Index score. These score changes were used to estimate health state utilities and direct medical costs. Quality-adjusted life-years (QALYs) and incremental cost per QALY gained were calculated by baseline ACPA groups (Q1, 28-234 AU/ml; Q2, 235-609 AU/ml; Q3, 613-1045 AU/ml; and Q4, 1060-4894 AU/ml). Scenario analysis and one-way and probabilistic sensitivity analyses were used to evaluate robustness of model assumptions. Abatacept resulted in QALY gain versus adalimumab in ACPA Q1, Q3, and Q4; between-treatment difference (difference: Q1, -0.115 Q2, -0.009 Q3, 0.045; and Q4, 0.279). Total lifetime discounted cost was higher for abatacept versus adalimumab in most quartiles (Q2, £77,612 vs. £77,546; Q3, £74,441 vs. £73,263; and Q4, £78,428 vs. £76,696) because of longer time on treatment. Incremental cost per QALY for abatacept (vs. adalimumab) was the lowest in the high ACPA titer group (Q4, £6200/QALY), followed by the next lowest titer group (Q3, £26,272/QALY). Abatacept is a cost effective alternative to adalimumab in patients with RA with high ACPA levels. Copyright © 2018 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  18. Patient-reported outcomes in KEYNOTE-006, a randomised study of pembrolizumab versus ipilimumab in patients with advanced melanoma.

    PubMed

    Petrella, Teresa M; Robert, Caroline; Richtig, Erika; Miller, Wilson H; Masucci, Giuseppe V; Walpole, Euan; Lebbe, Celeste; Steven, Neil; Middleton, Mark R; Hille, Darcy; Zhou, Wei; Ibrahim, Nageatte; Cebon, Jonathan

    2017-11-01

    Report results of patient-reported health-related quality of life (HRQoL) and symptoms from phase III KEYNOTE-006 study of pembrolizumab versus ipilimumab in patients with ipilimumab-naive advanced melanoma. Patients received pembrolizumab 10 mg/kg every 2 (Q2W) or every 3 weeks (Q3W) for up to 2 years, or four cycles of ipilimumab 3 mg/kg Q3W. The European Organisation for Research and Treatment of Cancer Quality of Life Questionnaire C30 (EORTC QLQ-C30) was administered at baseline and throughout the study. Patient-reported outcome (PRO) analyses were pre-specified exploratory endpoints; the primary PRO assessment was the score change from baseline to week 12 in EORTC QLQ-C30 global health status (GHS)/HRQoL score between the arms using constrained longitudinal data analysis. The PRO analysis population included 776 patients: pembrolizumab Q2W (n = 270); pembrolizumab Q3W (n = 266); ipilimumab (n = 240). Baseline GHS was similar across arms. QLQ-C30 compliance rates at week 12 were 87% (n = 214), 97% (n = 226), and 96% (n = 178), for the pembrolizumab Q2W, pembrolizumab Q3W, and ipilimumab arms, respectively. From baseline to week 12, GHS/HRQoL scores were better maintained with pembrolizumab than with ipilimumab (decrease of -1.9 and -2.5 for pembrolizumab versus -10.0 for ipilimumab; p < 0.001 for each pembrolizumab arm versus ipilimumab). Fewer patients treated with pembrolizumab experienced deterioration in GHS at week 12 (31% for pembrolizumab Q2W; 29% for Q3W and 44% for ipilimumab), with similar trends observed for individual functioning and symptoms scales. HRQoL was better maintained with pembrolizumab than with ipilimumab in patients with ipilimumab-naive advanced melanoma. CLINICALTRIALS. NCT01866319. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  19. Comparison of the IAEA TRS-398 and AAPM TG-51 absorbed dose to water protocols in the dosimetry of high-energy photon and electron beams

    NASA Astrophysics Data System (ADS)

    Saiful Huq, M.; Andreo, Pedro; Song, Haijun

    2001-11-01

    The International Atomic Energy Agency (IAEA TRS-398) and the American Association of Physicists in Medicine (AAPM TG-51) have published new protocols for the calibration of radiotherapy beams. These protocols are based on the use of an ionization chamber calibrated in terms of absorbed dose to water in a standards laboratory's reference quality beam. This paper compares the recommendations of the two protocols in two ways: (i) by analysing in detail the differences in the basic data included in the two protocols for photon and electron beam dosimetry and (ii) by performing measurements in clinical photon and electron beams and determining the absorbed dose to water following the recommendations of the two protocols. Measurements were made with two Farmer-type ionization chambers and three plane-parallel ionization chamber types in 6, 18 and 25 MV photon beams and 6, 8, 10, 12, 15 and 18 MeV electron beams. The Farmer-type chambers used were NE 2571 and PTW 30001, and the plane-parallel chambers were a Scanditronix-Wellhöfer NACP and Roos, and a PTW Markus chamber. For photon beams, the measured ratios TG-51/TRS-398 of absorbed dose to water Dw ranged between 0.997 and 1.001, with a mean value of 0.999. The ratios for the beam quality correction factors kQ were found to agree to within about +/-0.2% despite significant differences in the method of beam quality specification for photon beams and in the basic data entering into kQ. For electron beams, dose measurements were made using direct ND,w calibrations of cylindrical and plane-parallel chambers in a 60Co gamma-ray beam, as well as cross-calibrations of plane-parallel chambers in a high-energy electron beam. For the direct ND,w calibrations the ratios TG-51/TRS-398 of absorbed dose to water Dw were found to lie between 0.994 and 1.018 depending upon the chamber and electron beam energy used, with mean values of 0.996, 1.006, and 1.017, respectively, for the cylindrical, well-guarded and not well-guarded plane-parallel chambers. The Dw ratios measured for the cross-calibration procedures varied between 0.993 and 0.997. The largest discrepancies for electron beams between the two protocols arise from the use of different data for the perturbation correction factors pwall and pdis of cylindrical and plane-parallel chambers, all in 60Co. A detailed analysis of the reasons for the discrepancies is made which includes comparing the formalisms, correction factors and the quantities in the two protocols.

  20. Assessment of Quality of Life (QOL) in Obsessive Compulsive Disorder (OCD) and Dysthymic Disorder (DD): A Comparative Study.

    PubMed

    Vasudev, Roopesh Gopal Nariyandada; Yallappa, Sudarshan Chikkanayakanahalli; Saya, Ganesh Kumar

    2015-05-01

    There is paucity of data on Quality of Life (QOL) in non-psychotic mental disorders. To assess the Quality of Life (QOL) in Obsessive Compulsive Disorder (OCD) and compare it with Dysthymic Disorder (DD). This hospital based cross-sectional study was conducted in 30 patients each diagnosed to have OCD and DD during October 2009 to September 2011 in a medical institution in Davanagere, Karnataka, India. DSM-IV-TR (Diagnostic statistical manual-IV-Text Revised) criteria was used for diagnosis of OCD and DD. Yale Brown Obsessive Compulsive Scale (Y-BOCS) and WHO QOL BREF (brief form) scales were used. Data was analysed by independent sample t-test. Overall QOL score was 51.07(SD=11.47) and 50.91(SD=7.41) in OCD and DD groups respectively. QOL score was comparatively low in psychological domain with score of 44.12(SD=14.14) and 45.10(12.35) in OCD and DD respectively. There was no significant difference in the QOL score of the two groups with respect to socio demographic variables in OCD group, but it was different with respect to place of residence in DD group (p<0.05). In Q1(perception on quality of life) and Q2 (perception on quality of health) domain, QOL score was marginally higher than average in both the groups. In Y-BOCS scale, no statistical significant association was found between severity of OCD and QOL score in each of the domains (p>0.05). Overall QOL score was average and there was no significant difference of QOL score between the OCD and DD groups implying that both these non-psychotic mental disorders may have same influence or effect on QOL of the subjects. Further analytical studies will explore the associated factors of QOL in OCD and DD.

  1. Assessment of Quality of Life (QOL) in Obsessive Compulsive Disorder (OCD) and Dysthymic Disorder (DD): A Comparative Study

    PubMed Central

    Vasudev, Roopesh Gopal Nariyandada; Yallappa, Sudarshan Chikkanayakanahalli

    2015-01-01

    Introduction There is paucity of data on Quality of Life (QOL) in non-psychotic mental disorders. Aim To assess the Quality of Life (QOL) in Obsessive Compulsive Disorder (OCD) and compare it with Dysthymic Disorder (DD). Materials and Methods This hospital based cross-sectional study was conducted in 30 patients each diagnosed to have OCD and DD during October 2009 to September 2011 in a medical institution in Davanagere, Karnataka, India. DSM-IV-TR (Diagnostic statistical manual-IV-Text Revised) criteria was used for diagnosis of OCD and DD. Yale Brown Obsessive Compulsive Scale (Y-BOCS) and WHO QOL BREF (brief form) scales were used. Data was analysed by independent sample t-test. Results Overall QOL score was 51.07(SD=11.47) and 50.91(SD=7.41) in OCD and DD groups respectively. QOL score was comparatively low in psychological domain with score of 44.12(SD=14.14) and 45.10(12.35) in OCD and DD respectively. There was no significant difference in the QOL score of the two groups with respect to socio demographic variables in OCD group, but it was different with respect to place of residence in DD group (p<0.05). In Q1(perception on quality of life) and Q2 (perception on quality of health) domain, QOL score was marginally higher than average in both the groups. In Y-BOCS scale, no statistical significant association was found between severity of OCD and QOL score in each of the domains (p>0.05). Conclusion Overall QOL score was average and there was no significant difference of QOL score between the OCD and DD groups implying that both these non-psychotic mental disorders may have same influence or effect on QOL of the subjects. Further analytical studies will explore the associated factors of QOL in OCD and DD. PMID:26155540

  2. Cleaning procedure for improved photothermal background of toroidal optical microresonators

    NASA Astrophysics Data System (ADS)

    Horak, Erik H.; Knapper, Kassandra A.; Heylman, Kevin D.; Goldsmith, Randall H.

    2016-09-01

    High Q-factors and small mode volumes have made toroidal optical microresonators exquisite sensors to small shifts in the effective refractive index of the WGM modes. Eliminating contaminants and improving quality factors is key for many different sensing techniques, and is particularly important for photothermal imaging as contaminants add photothermal background obscuring objects of interest. Several different cleaning procedures including wet- and dry-chemical procedures are tested for their effect on Q-factors and photothermal background. RCA cleaning was shown to be successful in contrast to previously described acid cleaning procedures, most likely due to the different surface reactivity of the acid reagents used. UV-ozone cleaning was shown to be vastly superior to O2 plasma cleaning procedures, significantly reducing the photothermal background of the resonator.

  3. The calibration of a Scanditronix-Wellhöfer thimble chamber for photon dosimetry using the IAEA TRS 277 code of practice.

    PubMed

    Fourie, O L

    2004-03-01

    This note investigates the calibration of a Scanditronix-Wellhöfer type FC65-G ionisation chamber to be used in clinical photon dosimetry. The current Adaptation by the Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) of the IAEA TRS 277 dosimetry protocol makes no provision for this type of chamber. The absorbed dose to air calibration coefficient ND was therefore calculated from the air kerma calibration coefficient NK using the formalism of the IAEA TRS 277 protocol and it is shown that the value of the correction factor kmkatt for the FC65-G chamber is identical to that of the NE 2571 chamber. ND was also determined experimentally from a cross calibration against an NE 2571 dosimetry. It was found that there is a good correspondence between the calculated and measured values. To establish to what extent the ACPSEM Adaptation can be used for the FC65-G chamber, values for the ratio of stopping powers in water and air (Sw,air)Q and the perturbation correction factor pQ were calculated using the TRS 277 protocol. From these results it is shown that over the range of beam qualities TPR20,10 = 0.59 to TPR20,10 = 0.78 the Adaptation can be used for the FC65-G chamber.

  4. Cross-national differences in hypochondriasis symptoms between Korean and American outpatients with major depressive disorder.

    PubMed

    Chang, Kyung-Ah Judy; Kim, Kiwon; Fava, Maurizio; Mischoulon, David; Hong, Jin Pyo; Kim, Daniel J H; Heo, Jung-Yoon; Choi, Hong; Jeon, Hong Jin

    2016-11-30

    Hypochondriasis is defined as the tendency to worry excessively about having a serious illness. This study aimed to investigate cross-national differences in hypochondriasis symptoms between Korean and American patients with major depressive disorder (MDD). This study examined 1592 Korean and 3744 American MDD outpatients of age ≥18 years using the Hamilton Rating Scale for Depression (HAM-D) and the Quality of Life Enjoyment and Satisfaction Questionnaire (Q-LES-Q-SF). Korean MDD patients exhibited significantly higher scores for hypochondriasis than Americans after controlling for total HAM-D scores and demographic variables (p<0.0001), even though Americans had significantly higher total HAM-D scores (p<0.0001). Multivariate logistic regression analyses revealed that hypochondriasis was significantly associated with somatic and psychic anxiety, insomnia-middle, and suicide for both Korean and American MDD patients after adjusting for demographic covariates. Among all factors, somatic anxiety was the most strongly associated with hypochondriasis in both Korean (AOR=2.14, 95% CI 1.31-3.52) and American (AOR=1.98, 95% CI 1.69-2.31) MDD outpatients. Hypochondriasis symptoms are more prevalent among Korean than American MDD patients but appear to be associated with high levels of somatic anxiety regardless of culture. This suggests that cultural and personal factors play a shared role in the presentation of hypochondriasis symptoms. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. Study of thermally-induced optical bistability and the role of surface treatments in Si-based mid-infrared photonic crystal cavities.

    PubMed

    Shankar, Raji; Bulu, Irfan; Leijssen, Rick; Lončar, Marko

    2011-11-21

    We report the observation of optical bistability in Si-based photonic crystal cavities operating around 4.5 µm. Time domain measurements indicate that the source of this optical bistability is thermal, with a time constant on the order of 5 µs. Quality (Q) factor improvement is shown by the use of surface treatments (wet processes and annealing), resulting in a significant increase in Q-factor, which in our best devices is on the order of ~45,000 at 4.48 µm. After annealing in a N(2) environment, optical bistability is no longer seen in our cavities. © 2011 Optical Society of America

  6. MedAd-AppQ: A quality assessment tool for medication adherence apps on iOS and android platforms.

    PubMed

    Ali, Eskinder Eshetu; Teo, Amanda Kai Sin; Goh, Sherlyn Xue Lin; Chew, Lita; Yap, Kevin Yi-Lwern

    2018-02-02

    With the recent proliferation of smartphone medication adherence applications (apps), it is increasingly more difficult for patients and clinicians to identify the most useful app. To develop a quality assessment tool for medication adherence apps, and evaluate the quality of such apps from the major app stores. In this study, a Medication Adherence App Quality assessment tool (MedAd-AppQ) was developed and two evaluators independently assessed apps that fulfilled the following criteria: availability in English, had at least a medication reminder feature, non-specific to certain disease conditions (generic apps), free of technical malfunctions and availability on both the iPhone Operating System (iOS) and Android platforms. Descriptive statistics, Mann-Whitney U test, Pearson product moment correlation and Spearman rank-order correlation were used for statistical analysis. MedAd-AppQ was designed to have 24 items (total 43 points) categorized under three sections: content reliability (11 points), feature usefulness (29 points) and feature convenience (3 points). The three sections of MedAd-AppQ were found to have inter-rater correlation coefficients of 0.801 (p-value < .001) or higher. Based on analysis of 52 apps (27 iOS and 25 Android), quality scores ranged between 7/43 (16.3%) and 28/43 (65.1%). There was no significant difference between the quality scores of the Android and iOS versions. None of the apps had features for self-management of side effects. Only two apps in each platform provided disease-related and/or medication information. MedAd-AppQ can be used to reliably assess the quality of adherence apps. Clinicians can use the tool in selecting apps for use by patients. Developers of adherence apps should consider features that provide therapy-related information and help patients in medications and side-effects management. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Probing a new strongly interacting sector via composite diboson resonances

    NASA Astrophysics Data System (ADS)

    Ko, P.; Yu, Chaehyun; Yuan, Tzu-Chiang

    2017-06-01

    Diphoton resonance was a crucial discovery mode for the 125 GeV Standard Model Higgs boson at the Large Hadron Collider (LHC). This mode or the more general diboson modes may also play an important role in probing for new physics beyond the Standard Model. In this paper, we consider the possibility that a diphoton resonance is due to a composite scalar or pseudoscalar boson, whose constituents are either new hyperquarks Q or scalar hyperquarks Q ˜ confined by a new hypercolor force at a confinement scale Λh. Assuming the mass mQ (or mQ ˜) ≫Λh, a diphoton resonance could be interpreted as either a Q Q ¯ (1S0) state ηQ with JP C=0-+ or a Q ˜ Q˜ †(1S0) state ηQ ˜ with JP C=0++. For the Q Q ¯ scenario, there will be a spin-triplet partner ψQ which is slightly heavier than ηQ due to the hyperfine interactions mediated by hypercolor gluon exchange; while for the Q ˜Q˜† scenario, the spin-triplet partner χQ ˜ arises from higher radial excitation with nonzero orbital angular momentum. We consider productions and decays of ηQ, ηQ ˜, ψQ, and χQ ˜ at the LHC using the nonrelativistic QCD factorization approach. We discuss how to test these scenarios by using the Drell-Yan process and the forward dijet azimuthal angular distributions to determine the JP C quantum number of the diphoton resonance. Constraints on the parameter space can be obtained by interpreting some of the small diphoton "excesses" reported by the LHC as the composite scalar or pseudoscalar of the model. Another important test of the model is the presence of a nearby hypercolor-singlet but color-octet state like the 1S0 state ηQ8 or ηQ˜8, which can also be constrained by dijet or monojet plus monophoton data. Both possibilities of a large or small width of the resonance can be accommodated, depending on whether the hyper-glueball states are kinematically allowed in the final state or not.

  8. Genome-wide association study of breast cancer in Latinas identifies novel protective variants on 6q25.

    PubMed

    Fejerman, Laura; Ahmadiyeh, Nasim; Hu, Donglei; Huntsman, Scott; Beckman, Kenneth B; Caswell, Jennifer L; Tsung, Karen; John, Esther M; Torres-Mejia, Gabriela; Carvajal-Carmona, Luis; Echeverry, María Magdalena; Tuazon, Anna Marie D; Ramirez, Carolina; Gignoux, Christopher R; Eng, Celeste; Gonzalez-Burchard, Esteban; Henderson, Brian; Le Marchand, Loic; Kooperberg, Charles; Hou, Lifang; Agalliu, Ilir; Kraft, Peter; Lindström, Sara; Perez-Stable, Eliseo J; Haiman, Christopher A; Ziv, Elad

    2014-10-20

    The genetic contributions to breast cancer development among Latinas are not well understood. Here we carry out a genome-wide association study of breast cancer in Latinas and identify a genome-wide significant risk variant, located 5' of the Estrogen Receptor 1 gene (ESR1; 6q25 region). The minor allele for this variant is strongly protective (rs140068132: odds ratio (OR) 0.60, 95% confidence interval (CI) 0.53-0.67, P=9 × 10(-18)), originates from Indigenous Americans and is uncorrelated with previously reported risk variants at 6q25. The association is stronger for oestrogen receptor-negative disease (OR 0.34, 95% CI 0.21-0.54) than oestrogen receptor-positive disease (OR 0.63, 95% CI 0.49-0.80; P heterogeneity=0.01) and is also associated with mammographic breast density, a strong risk factor for breast cancer (P=0.001). rs140068132 is located within several transcription factor-binding sites and electrophoretic mobility shift assays with MCF-7 nuclear protein demonstrate differential binding of the G/A alleles at this locus. These results highlight the importance of conducting research in diverse populations.

  9. Genome-wide association study of breast cancer in Latinas identifies novel protective variants on 6q25

    PubMed Central

    Fejerman, Laura; Ahmadiyeh, Nasim; Hu, Donglei; Huntsman, Scott; Beckman, Kenneth B.; Caswell, Jennifer L.; Tsung, Karen; John, Esther M.; Torres-Mejia, Gabriela; Carvajal-Carmona, Luis; Echeverry, María Magdalena; Tuazon, Anna Marie D.; Ramirez, Carolina; Carvajal-Carmona, Luis; Echeverry, María Magdalena; Bohórquez, Mabel Elena; Prieto, Rodrigo; Criollo, Ángel; Ramírez, Carolina; Estrada, Ana Patricia; Suáres, John Jairo; Mateus, Gilbert; Castro, Jorge Mario; Sánchez, Yesid; Murillo, Raúl; Lucia Serrano, Martha; Sanabria, Carolina; Olaya, Justo Germán; Bolaños, Fernando; Vélez, Alejandro; Carmona, Jenny Andrea; Vélez, Alejandro; Rodríguez, Nancy Guerrero; Serón Sousa, Cristina; Mendez, Cesar Eduardo Alvarez; Galviz, Ana Isabel Orduz; Gignoux, Christopher R.; Eng, Celeste; Gonzalez-Burchard, Esteban; Henderson, Brian; Marchand, Loic Le; Kooperberg, Charles; Hou, Lifang; Agalliu, Ilir; Kraft, Peter; Lindström, Sara; Perez-Stable, Eliseo J.; Haiman, Christopher A.; Ziv, Elad

    2014-01-01

    The genetic contributions to breast cancer development among Latinas are not well understood. Here we carry out a genome-wide association study of breast cancer in Latinas and identify a genome-wide significant risk variant, located 5′ of the Estrogen Receptor 1 gene (ESR1; 6q25 region). The minor allele for this variant is strongly protective (rs140068132: odds ratio (OR) 0.60, 95% confidence interval (CI) 0.53–0.67, P=9 × 10−18), originates from Indigenous Americans and is uncorrelated with previously reported risk variants at 6q25. The association is stronger for oestrogen receptor-negative disease (OR 0.34, 95% CI 0.21–0.54) than oestrogen receptor-positive disease (OR 0.63, 95% CI 0.49–0.80; P heterogeneity=0.01) and is also associated with mammographic breast density, a strong risk factor for breast cancer (P=0.001). rs140068132 is located within several transcription factor-binding sites and electrophoretic mobility shift assays with MCF-7 nuclear protein demonstrate differential binding of the G/A alleles at this locus. These results highlight the importance of conducting research in diverse populations. PMID:25327703

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peng, Y.K.M.; Strickler, D.J.

    The spherical torus is a very small aspect ratio (A < 2) confinement concept obtained by retaining only the indispensable components inboard to the plasma torus. MHD equilibrium calculations show that spherical torus plasmas with safety factor q > 2 are characterized by high toroidal beta (..beta../sub t/ > 0.2), low poloidal beta (..beta../sub p/ < 0.3), naturally large elongation (kappa greater than or equal to 2), large plasma current with I/sub p//(aB/sub t0/) up to about 7 MA/mT, strong paramagnetism (B/sub t//B/sub t0/ > 1.5), and strong plasma helicity (F comparable to THETA). A large near-omnigeneous region is seenmore » at the large-major-radius, bad-curvature region of the plasma in comparison with the conventional tokamaks. These features combine to engender the spherical torus plasma in a unique physics regime which permits compact fusion at low field and modest cost. Because of its strong paramagnetism and helicity, the spherical torus plasma shares some of the desirable features of spheromak and reversed-field pinch (RFP) plasmas, but with tokamak-like confinement and safety factor q. The general class of spherical tori, which includes the spherical tokamak (q > 1), the spherical pinch (1 > q > O), and the spherical RFP (q < O), have magnetic field configurations unique in comparison with conventional tokamaks and RFPs. 22 refs., 12 figs.« less

  11. Analytical and experimental procedures for determining propagation characteristics of millimeter-wave gallium arsenide microstrip lines

    NASA Technical Reports Server (NTRS)

    Romanofsky, Robert R.

    1989-01-01

    In this report, a thorough analytical procedure is developed for evaluating the frequency-dependent loss characteristics and effective permittivity of microstrip lines. The technique is based on the measured reflection coefficient of microstrip resonator pairs. Experimental data, including quality factor Q, effective relative permittivity, and fringing for 50-omega lines on gallium arsenide (GaAs) from 26.5 to 40.0 GHz are presented. The effects of an imperfect open circuit, coupling losses, and loading of the resonant frequency are considered. A cosine-tapered ridge-guide text fixture is described. It was found to be well suited to the device characterization.

  12. Nanospectrofluorometry inside single living cell by scanning near-field optical microscopy

    NASA Astrophysics Data System (ADS)

    Lei, F. H.; Shang, G. Y.; Troyon, M.; Spajer, M.; Morjani, H.; Angiboust, J. F.; Manfait, M.

    2001-10-01

    Near-field fluorescence spectra with subdiffraction limit spatial resolution have been taken in the proximity of mitochondrial membrane inside breast adenocarcinoma cells (MCF7) treated with the fluorescent dye (JC-1) by using a scanning near-field optical microscope coupled with a confocal laser microspectrofluorometer. The probe-sample distance control is based on a piezoelectric bimorph shear force sensor having a static spring constant k=5 μN/nm and a quality factor Q=40 in a physiological medium of viscosity η=1.0 cp. The sensitivity of the force sensor has been tested by imaging a MCF7 cell surface.

  13. Directly q-switched high power resonator based on XLMA-fibers

    NASA Astrophysics Data System (ADS)

    Giesberts, M.; Fitzau, O.; Hoffmann, H.-D.; Lange, R.; Bachert, C.; Krause, V.

    2018-02-01

    In this paper we present a simple approach to achieving nanosecond pulses from a directly q-switched high-power resonator based on extra-large mode area (XLMA) fibers with a beam quality factor M2 < 15. An average output power of > 500 W has been demonstrated for repetition frequencies between 50-100 kHz. The resonator consists of a single fiber q-switched with soldered Pockels-cells which exhibit a very high contrast ratio leading to output pulses down to about 10 ns and peak powers up to > 250 kW at 1064 nm wavelength. By using this design instead of a fiber MOPA setup, a cost-effective and less complex system could be implemented.

  14. Ligand-based 3D QSAR analysis of reactivation potency of mono- and bis-pyridinium aldoximes toward VX-inhibited rat acetylcholinesterase.

    PubMed

    Dolezal, Rafael; Korabecny, Jan; Malinak, David; Honegr, Jan; Musilek, Kamil; Kuca, Kamil

    2015-03-01

    To predict unknown reactivation potencies of 12 mono- and bis-pyridinium aldoximes for VX-inhibited rat acetylcholinesterase (rAChE), three-dimensional quantitative structure-activity relationship (3D QSAR) analysis has been carried out. Utilizing molecular interaction fields (MIFs) calculated by molecular mechanical (MMFF94) and quantum chemical (B3LYP/6-31G*) methods, two satisfactory ligand-based CoMFA models have been developed: 1. R(2)=0.9989, Q(LOO)(2)=0.9090, Q(LTO)(2)=0.8921, Q(LMO(20%))(2)=0.8853, R(ext)(2)=0.9259, SDEP(ext)=6.8938; 2. R(2)=0.9962, Q(LOO)(2)=0.9368, Q(LTO)(2)=0.9298, Q(LMO(20%))(2)=0.9248, R(ext)(2)=0.8905, SDEP(ext)=6.6756. High statistical significance of the 3D QSAR models has been achieved through the application of several data noise reduction techniques (i.e. smart region definition SRD, fractional factor design FFD, uninformative/iterative variable elimination UVE/IVE) on the original MIFs. Besides the ligand-based CoMFA models, an alignment molecular set constructed by flexible molecular docking has been also studied. The contour maps as well as the predicted reactivation potencies resulting from 3D QSAR analyses help better understand which structural features are associated with increased reactivation potency of studied compounds. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Characterization of genome-wide association-identified variants for atrial fibrillation in African Americans.

    PubMed

    Delaney, Jessica T; Jeff, Janina M; Brown, Nancy J; Pretorius, Mias; Okafor, Henry E; Darbar, Dawood; Roden, Dan M; Crawford, Dana C

    2012-01-01

    Despite a greater burden of risk factors, atrial fibrillation (AF) is less common among African Americans than European-descent populations. Genome-wide association studies (GWAS) for AF in European-descent populations have identified three predominant genomic regions associated with increased risk (1q21, 4q25, and 16q22). The contribution of these loci to AF risk in African American is unknown. We studied 73 African Americans with AF from the Vanderbilt-Meharry AF registry and 71 African American controls, with no history of AF including after cardiac surgery. Tests of association were performed for 148 SNPs across the three regions associated with AF, and 22 SNPs were significantly associated with AF (P<0.05). The SNPs with the strongest associations in African Americans were both different from the index SNPs identified in European-descent populations and independent from the index European-descent population SNPs (r(2)<0.40 in HapMap CEU): 1q21 rs4845396 (odds ratio [OR] 0.30, 95% confidence interval [CI] 0.13-0.67, P = 0.003), 4q25 rs4631108 (OR 3.43, 95% CI 1.59-7.42, P = 0.002), and 16q22 rs16971547 (OR 8.1, 95% CI 1.46-45.4, P = 0.016). Estimates of European ancestry were similar among cases (23.6%) and controls (23.8%). Accordingly, the probability of having two copies of the European derived chromosomes at each region did not differ between cases and controls. Variable European admixture at known AF loci does not explain decreased AF susceptibility in African Americans. These data support the role of 1q21, 4q25, and 16q22 variants in AF risk for African Americans, although the index SNPs differ from those identified in European-descent populations.

  16. Comparison of direct and flow integration based charge density population analyses.

    PubMed

    Francisco, E; Martín Pendas, A; Blanco, M A; Costales, A

    2007-12-06

    Different exhaustive and fuzzy partitions of the molecular electron density (rho) into atomic densities (rho(A)) are used to compute the atomic charges (Q(A)) of a representative set of molecules. The Q(A)'s derived from a direct integration of rho(A) are compared to those obtained from integrating the deformation density rho(def) = rho - rho(0) within each atomic domain. Our analysis shows that the latter methods tend to give Q(A)'s similar to those of the (arbitrary) reference atomic densities rho(A)(0) used in the definition of the promolecular density, rho(0) = SigmaArho(A)(0). Moreover, we show that the basis set independence of these charges is a sign not of their intrinsic quality, as commonly stated, but of the practical insensitivity on the basis set of the atomic domains that are employed in this type of methods.

  17. Associations between liking for fat, sweet or salt and obesity risk in French adults: a prospective cohort study.

    PubMed

    Lampuré, Aurélie; Castetbon, Katia; Deglaire, Amélie; Schlich, Pascal; Péneau, Sandrine; Hercberg, Serge; Méjean, Caroline

    2016-07-04

    Individual sensory liking appears to be an important determinant of dietary intake and may consequently influence weight status. Cross-sectional studies have shown positive association between fat liking and weight status and equivocal results regarding salt and sweet liking. Moreover, the contribution of dietary intake to explain this relationship has not been studied yet. We investigated the prospective association between sensory liking for fat, sweet or salt and the onset of obesity over 5 years in adults, and the mediating effect of dietary intake. We prospectively examine the risk of obesity among 24,776 French adults participating in the NutriNet-Santé cohort study. Liking scores and dietary data were assessed at baseline using a validated web-based questionnaire and 24 h records, respectively. Self-reported anthropometric data were collected using web-based questionnaire, each year during 5 years. Associations between quartiles of liking for fat, sweet or salt and obesity risk, and the mediating effect of diet were assessed by multivariate Cox proportional hazards models stratified by gender, adjusted for sociodemographic and lifestyle factors. In both genders, sensory liking for fat was associated with an increased risk of obesity (hazard ratios for quartile 4 compared to quartile 1, men: HR(Q4vs.Q1) = 2.39 (95% CI 1.39,4.11) P-trend = 0.0005, women: HR(Q4vs.Q1) = 2.02 (1.51,2.71) P-trend = <0.0001). Dietary intake explained 32% in men and 52% in women of the overall variation of liking for fat in obesity. Sensory liking for sweet was associated with a decreased risk of obesity (men: HR(Q4vs.Q1) = 0.51 (0.31,0.83) P-trend = 0.01, women: HR(Q4vs.Q1) = 0.72 (0.54,0.96) P-trend = 0.035). No significant association between salt liking and the risk of obesity was found. Unlike sweet and salt liking, higher liking for fat appears to be a major risk factor of obesity, largely explained by dietary intake. Our findings emphasize the need to centrally position sensory liking in obesity prevention.

  18. Implementing a web-based oncology protocol system in Australia: evaluation of the first 3 years of operation.

    PubMed

    Hains, I M; Ward, R L; Pearson, S-A

    2012-01-01

    EviQ is a web-based oncology protocol system launched across Australia in 2005 (http://www.eviq.org.au). We evaluated eviQ use at the point-of-care and determined the factors impacting on its uptake and routine use in the first three years of operation. We conducted a suite of qualitative and quantitative studies with over 200 Australian oncology physicians, nurses and pharmacists working at treatment centres in diverse geographical locations. EviQ was part of routine care at many hospitals; however, the way in which it was used at the point-of-care varies according to clinician roles and hospital location. We identified a range of factors impacting on eviQ uptake and routine use. Infrastructure, such as availability of point-of-care computers, and formal policies endorsing eviQ are fundamental to increasing uptake. Furthermore, the level of clinical and computer experience of end-users, the attitudes and behaviour of clinicians, endorsement and promotion strategies, and level and type of eviQ education all need to be considered and managed to ensure that the system is being used to its full potential. Our findings show that the dissemination of web-based treatment protocols does not guarantee widespread use. Organisational, environmental and clinician-specific factors play a role in uptake and utilisation. The deployment of sufficient computer infrastructure, implementation of targeted training programmes and hospital policies and investment in marketing approaches are fundamental to uptake and continued use. This study highlights the value of ongoing monitoring and evaluation to ensure systems like eviQ achieve their primary purpose - reducing treatment variation and improving quality of care. © 2010 The Authors. Internal Medicine Journal © 2010 Royal Australasian College of Physicians.

  19. Characteristic analysis and comparison of two kinds of hybrid plasmonic annular resonators

    NASA Astrophysics Data System (ADS)

    Zhou, Jie; Shi, Feifei; Zhou, Taojie; He, Kebo; Qiu, Bocang; Zhang, Zhaoyu

    2017-04-01

    We designed two kinds of hybrid plasmonic annular resonators with different cross-sectional shapes, i.e., a square and circle called "square ring" and "circle ring" resonators, respectively. Both resonators feature an ultracompact mode volume of ˜10-4 μm3 and a relatively high-quality factor of ˜102 at a submicron footprint within our studied wavelength range from 400 to 900 nm. Their performance as defined by the Q/V ratio (quality factor over mode volume) is enhanced considerably with a reduction in their physical dimensions. There exists critical annular radii, which increase from 400 to 600 nm with an increase in the azimuthal numbers from m=7 to m=10, if the two types of rings are compared with the same mode numbers and same ring thickness of 120 nm. Below the critical radii, the circle ring resonator outperforms the square ring resonator in terms of the Q/V ratio, and the difference in Q/V of the two types of rings increases rapidly with the decrease of the radii. On the other hand, they have critical annular radii of ˜250 nm, below which the square ring resonator outperforms the circle ring resonator at the wavelengths of 490 and 595 nm however, the difference in Q/V of the two types of rings remains small within the radii range we consider. It is suggested that, in practice, with the consideration of the wavelength of green emission for these two ring structures with radii from 100 to 500 nm and ring thickness ˜120 nm, they have a negligible difference in Q/V performance.

  20. Optimization of one-dimensional photonic crystals with double layer magneto-active defect

    NASA Astrophysics Data System (ADS)

    Mikhailova, T. V.; Berzhansky, V. N.; Shaposhnikov, A. N.; Karavainikov, A. V.; Prokopov, A. R.; Kharchenko, Yu. M.; Lukienko, I. M.; Miloslavskaya, O. V.; Kharchenko, M. F.

    2018-04-01

    Success of practical implementation of one-dimensional photonic crystals with magneto-active layers is evaluated in high values of magneto-optical (MO) quality factor Q and figure of merit F. The article relates to optimization of one-dimensional photonic crystals with double layer magneto-active (MA) defect of composition Bi1.0Y0.5Gd1.5Fe4.2Al0.8O12/Bi2.8Y0.2Fe5O12 located between the nongarnet dielectric Bragg mirrors. The structure design was performed by changing the number of layer pairs in Bragg mirrors m and the optical thickness of MA defect lM to achieve high values of MO characteristics. Theoretical predictions were confirmed by experimental investigation of eight synthesized configurations with m = 4 and m = 7. We have demonstrated the maximum Q = 15.1 deg and F = 7.5% at 624 nm for structure with m = 4 and lM = (2.5·λ0/2), where λ0 = 690 nm is the photonic band gap center. Configurations with m = 3 can also provide their effectiveness in realization. Maximum MO activity was achieved for configurations with m = 7. The structures with lM = (0.8·λ0/2) and lM = (2.5·λ0/2) showed respectively the specific Faraday rotation -113 deg/μm (that exceeds in 62 times the Faraday rotation of MA double layer film) at 654 nm and absolute Faraday rotation -20.6 deg at 626 nm.

  1. Light meson form factors at high Q2 from lattice QCD

    NASA Astrophysics Data System (ADS)

    Koponen, Jonna; Zimermmane-Santos, André; Davies, Christine; Lepage, G. Peter; Lytle, Andrew

    2018-03-01

    Measurements and theoretical calculations of meson form factors are essential for our understanding of internal hadron structure and QCD, the dynamics that bind the quarks in hadrons. The pion electromagnetic form factor has been measured at small space-like momentum transfer |q2| < 0.3 GeV2 by pion scattering from atomic electrons and at values up to 2.5 GeV2 by scattering electrons from the pion cloud around a proton. On the other hand, in the limit of very large (or infinite) Q2 = -q2, perturbation theory is applicable. This leaves a gap in the intermediate Q2 where the form factors are not known. As a part of their 12 GeV upgrade Jefferson Lab will measure pion and kaon form factors in this intermediate region, up to Q2 of 6 GeV2. This is then an ideal opportunity for lattice QCD to make an accurate prediction ahead of the experimental results. Lattice QCD provides a from-first-principles approach to calculate form factors, and the challenge here is to control the statistical and systematic uncertainties as errors grow when going to higher Q2 values. Here we report on a calculation that tests the method using an ηs meson, a 'heavy pion' made of strange quarks, and also present preliminary results for kaon and pion form factors. We use the nf = 2 + 1 + 1 ensembles made by the MILC collaboration and Highly Improved Staggered Quarks, which allows us to obtain high statistics. The HISQ action is also designed to have small dicretisation errors. Using several light quark masses and lattice spacings allows us to control the chiral and continuum extrapolation and keep systematic errors in check. Warning, no authors found for 2018EPJWC.17506016.

  2. EXERCISES THAT FACILITATE OPTIMAL HAMSTRING AND QUADRICEPS CO-ACTIVATION TO HELP DECREASE ACL INJURY RISK IN HEALTHY FEMALES: A SYSTEMATIC REVIEW OF THE LITERATURE.

    PubMed Central

    Dedinsky, Rachel; Baker, Lindsey; Imbus, Samuel; Bowman, Melissa

    2017-01-01

    Background Anterior cruciate ligament (ACL) injury is common among females due to many anatomic, hormonal, and neuromuscular risk factors. One modifiable risk factor that places females at increased risk of ACL injury is a poor hamstrings: quadriceps (H:Q) co-activation ratio, which should be 0.6 or greater in order to decrease the stress placed on the ACL. Exercises that produce more quadriceps dominant muscle activation can add to the tension placed upon the ACL, potentially increasing the risk of ACL injury. Hypothesis/Purpose The purpose of this systematic review was to compare quadriceps and hamstring muscle activation during common closed kinetic chain therapeutic exercises in healthy female knees to determine what exercises are able to produce adequate H:Q co-activation ratios. Study Design Systematic Review Methods Multiple online databases were systematically searched and screened for inclusion. Eight articles were identified for inclusion. Data on mean electromyography (EMG) activation of both quadriceps and hamstring muscles, % maximal voluntary isometric contraction (MVIC), and H:Q co-activation ratios were extracted from the studies. Quality assessment was performed on all included studies. Results Exercises analyzed in the studies included variations of the double leg squat, variations of the single leg squat, lateral step-up, Fitter, Stairmaster® (Core Health and Fitness, Vancouver, WA), and slide board. All exercises, except the squat machine with posterior support at the level of the scapula and feet placed 50 cm in front of the hips, produced higher quadriceps muscle activation compared to hamstring muscle activation. Conclusion Overall, two leg squats demonstrate poor H:Q co-activation ratios. Single leg exercises, when performed between 30 and 90 degrees of knee flexion, produce adequate H:Q ratios, thereby potentially reducing the risk of tensile stress on the ACL and ACL injury. Level of Evidence 2a- Systematic Review of Cohort Studies PMID:28217412

  3. Non-Invasive Evaluation of Cephalic Blood Flow in the +Gz Environment

    DTIC Science & Technology

    1988-09-25

    and the center frequency, COQ , is set by R3 and C1. The transfer function for this BPF is given by: K co„s/Q H(s)=-^ eq.5 S + S(OQ/Q -I- CO...0 where 0 = 20,1.4 < K < 8.6, COQ = 613.2 x 103 rad/s (97.6 kHz), Vout = output voltage, Vin = input voltage, and bandwidth = 7 kHz. To choose the...values of R1 - R4 and C1, these factors were first normalized: COQ = 1 rad/s, C1 = 1F, and R4 = lil. Then R1 = Q/K, R2 = Q, and R3 = 1i^. To denor

  4. 26 CFR 301.7216-0T - Table of contents.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 18 2010-04-01 2010-04-01 false Table of contents. 301.7216-0T Section 301.7216-0T Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) PROCEDURE AND... information for quality, peer, or conflict reviews. (q) through (r) [Reserved] For further guidance, see...

  5. Q2-EVOLUTION of ΔNγ Form Factors up to 4 (GEV/C)2 from Jlab Data

    NASA Astrophysics Data System (ADS)

    Aznauryan, I. G.

    2002-12-01

    We present the results on the ratios E(3/2)1+/M(3/2)1+ and S(3/2)1+/M(3/2)1+ for the γ*N → Δ(1232) transition at Q2 ≤ 4 (GeV/c)2 extracted from the p(e,e'p)π0 cross section using two approaches: dispersion relations and modified version of unitary isobar model. The obtained results are in good agreement with the results of other analyses obtained using truncated multipole expansion at Q2 = 0.4, 0.525, 0.65, 0.75, 0.9, 1.15, 1.45, 1.8 (GeV/c)2 and within dynamical and unitary isobar models at Q2 = 2.8, 4 (GeV/c)2. According to obtained results the ratio E(3/2)1+/M(3/2)1+ remains small in all investigated region of Q2 with very unclear tendency to cross zero above 2 (GeV/c)2. The absolute value of the ratio S(3/2)1+/M(3/2)1+ is clearly increasing with increasing Q2, while it should be a constant value in the pQCD asymptotics. So, at Q2 ≤ 4 (GeV/c)2 there is no evidence of approaching pQCD regime for these ratios. None of the soft approaches gives satisfactory description of the obtained results.

  6. Febrile patients admitted to remote hospitals in Northeastern Kenya: seroprevalence, risk factors and a clinical prediction tool for Q-Fever.

    PubMed

    Njeru, J; Henning, K; Pletz, M W; Heller, R; Forstner, C; Kariuki, S; Fèvre, E M; Neubauer, H

    2016-06-03

    Q fever in Kenya is poorly reported and its surveillance is highly neglected. Standard empiric treatment for febrile patients admitted to hospitals is antimalarials or penicillin-based antibiotics, which have no activity against Coxiella burnetii. This study aimed to assess the seroprevalence and the predisposing risk factors for Q fever infection in febrile patients from a pastoralist population, and derive a model for clinical prediction of febrile patients with acute Q fever. Epidemiological and clinical data were obtained from 1067 patients from Northeastern Kenya and their sera tested for IgG antibodies against Coxiella burnetii antigens by enzyme-linked-immunosorbent assay (ELISA), indirect immunofluorescence assay (IFA) and quantitative real-time PCR (qPCR). Logit models were built for risk factor analysis, and diagnostic prediction score generated and validated in two separate cohorts of patients. Overall 204 (19.1 %, 95 % CI: 16.8-21.6) sera were positive for IgG antibodies against phase I and/or phase II antigens or Coxiella burnetii IS1111 by qPCR. Acute Q fever was established in 173 (16.2 %, 95 % CI: 14.1-18.7) patients. Q fever was not suspected by the treating clinicians in any of those patients, instead working diagnosis was fever of unknown origin or common tropical fevers. Exposure to cattle (adjusted odds ratio [aOR]: 2.09, 95 % CI: 1.73-5.98), goats (aOR: 3.74, 95 % CI: 2.52-9.40), and animal slaughter (aOR: 1.78, 95 % CI: 1.09-2.91) were significant risk factors. Consumption of unpasteurized cattle milk (aOR: 2.49, 95 % CI: 1.48-4.21) and locally fermented milk products (aOR: 1.66, 95 % CI: 1.19-4.37) were dietary factors associated with seropositivity. Based on regression coefficients, we calculated a diagnostic score with a sensitivity 93.1 % and specificity 76.1 % at cut off value of 2.90: fever >14 days (+3.6), abdominal pain (+0.8), respiratory tract infection (+1.0) and diarrhoea (-1.1). Q fever is common in febrile Kenyan patients but underappreciated as a cause of community-acquired febrile illness. The utility of Q fever score and screening patients for the risky social-economic and dietary practices can provide a valuable tool to clinicians in identifying patients to strongly consider for detailed Q fever investigation and follow up on admission, and making therapeutic decisions.

  7. Standardization of a TaqMan-based real-time PCR for the detection of Mycobacterium tuberculosis-complex in human sputum.

    PubMed

    Barletta, Francesca; Vandelannoote, Koen; Collantes, Jimena; Evans, Carlton A; Arévalo, Jorge; Rigouts, Leen

    2014-10-01

    Real-time polymerase chain reaction (qPCR) was optimized for detecting Mycobacterium tuberculosis in sputum. Sputum was collected from patients (N = 112) with suspected pulmonary tuberculosis, tested by smear microscopy, decontaminated, and split into equal aliquots that were cultured in Löwenstein-Jensen medium and tested by qPCR for the small mobile genetic element IS6110. The human ERV3 sequence was used as an internal control. 3 of 112 (3%) qPCR failed. For the remaining 109 samples, qPCR diagnosed tuberculosis in 79 of 84 patients with culture-proven tuberculosis, and sensitivity was greater than microscopy (94% versus 76%, respectively, P < 0.05). The qPCR sensitivity was similar (P = 0.9) for smear-positive (94%, 60 of 64) and smear-negative (95%, 19 of 20) samples. The qPCR was negative for 24 of 25 of the sputa with negative microscopy and culture (diagnostic specificity 96%). The qPCR had 99.5% sensitivity and specificity for 211 quality control samples including 84 non-tuberculosis mycobacteria. The qPCR cost ∼5US$ per sample and provided same-day results compared with 2-6 weeks for culture. © The American Society of Tropical Medicine and Hygiene.

  8. Spins of primordial black holes formed in the matter-dominated phase of the Universe

    NASA Astrophysics Data System (ADS)

    Harada, Tomohiro; Yoo, Chul-Moon; Kohri, Kazunori; Nakao, Ken-Ichi

    2017-10-01

    Angular momentum plays very important roles in the formation of primordial black holes in the matter-dominated phase of the Universe if it lasts sufficiently long. In fact, most collapsing masses are bounced back due to centrifugal force, since angular momentum significantly grows before collapse. For masses with q ≤qc≃2.4 I1 /3σH1 /3 , where q is a nondimensional initial quadrupole moment parameter, σH is the density fluctuation at horizon entry t =tH, and I is a parameter of the order of unity, angular momentum gives a suppression factor ˜exp (-0.15 I4 /3σH-2 /3) to the production rate. As for masses with q >qc, the suppression factor is even stronger as ˜exp (-0.0046 q4/σH2) . We derive the spin distribution of primordial black holes and find that most of the primordial black holes are rapidly rotating near the extreme value a*=1 , where a* is the nondimensional Kerr parameter at their formation. The smaller σH is, the stronger the tendency towards the extreme rotation. Combining this result with the effect of anisotropy, we numerically and semianalytically estimate the production rate β0 of primordial black holes. Then we find that β0≃1.9 ×10-6fq(qc)I6σH2exp (-0.15 I4 /3σH-2 /3) for σH≲0.005 , while β0≃0.05556 σH5 for 0.005 ≲σH≲0.2 , where fq(qc) is the fraction of masses whose q is smaller than qc and we assume fq(qc) is not too small. We argue that matter domination significantly enhances the production of primordial black holes despite the suppression factor. If the end time tend of the matter-dominated phase satisfies tend≲(0.4 I σH)-1tH, the effect of the finite duration significantly suppresses primordial black hole formation and weakens the tendency towards large spins.

  9. 3D-QSAR Studies on Barbituric Acid Derivatives as Urease Inhibitors and the Effect of Charges on the Quality of a Model.

    PubMed

    Ul-Haq, Zaheer; Ashraf, Sajda; Al-Majid, Abdullah Mohammed; Barakat, Assem

    2016-04-30

    Urease enzyme (EC 3.5.1.5) has been determined as a virulence factor in pathogenic microorganisms that are accountable for the development of different diseases in humans and animals. In continuance of our earlier study on the helicobacter pylori urease inhibition by barbituric acid derivatives, 3D-QSAR (three dimensional quantitative structural activity relationship) advance studies were performed by Comparative Molecular Field Analysis (CoMFA) and Comparative Molecular Similarity Indices Analysis (CoMSIA) methods. Different partial charges were calculated to examine their consequences on the predictive ability of the developed models. The finest developed model for CoMFA and CoMSIA were achieved by using MMFF94 charges. The developed CoMFA model gives significant results with cross-validation (q²) value of 0.597 and correlation coefficients (r²) of 0.897. Moreover, five different fields i.e., steric, electrostatic, and hydrophobic, H-bond acceptor and H-bond donors were used to produce a CoMSIA model, with q² and r² of 0.602 and 0.98, respectively. The generated models were further validated by using an external test set. Both models display good predictive power with r²pred ≥ 0.8. The analysis of obtained CoMFA and CoMSIA contour maps provided detailed insight for the promising modification of the barbituric acid derivatives with an enhanced biological activity.

  10. Development and Initial Evaluation of 7 Tesla Q-Ball Imaging of the Human Brain

    PubMed Central

    Mukherjee, Pratik; Hess, Christopher P.; Xu, Duan; Han, Eric T.; Kelley, Douglas A.; Vigneron, Daniel B.

    2010-01-01

    Diffusion tensor imaging (DTI) noninvasively depicts white matter connectivity in regions where the Gaussian model of diffusion is valid, but yields inaccurate results where diffusion has a more complex distribution, such as fiber crossings. Q-ball imaging (QBI) overcomes this limitation of DTI by more fully characterizing the angular dependence of intravoxel diffusion with larger numbers of diffusion-encoding directional measurements at higher diffusion-weighting factors (b values). However, the former results in longer acquisition times and the latter results in lower signal-to-noise ratio (SNR). In this project, we developed specialized 7 Tesla acquisition methods utilizing novel radiofrequency pulses, 8-channel parallel imaging EPI, and high-order shimming with a phase-sensitive multichannel B0 field map reconstruction. These methods were applied in initial healthy adult volunteer studies which demonstrated the feasibility of performing 7T QBI. Preliminary comparisons of 3T with 7T within supratentorial crossing white matter tracts document a 79.5% SNR increase for b=3000 s/mm2 (p=0.0001), and a 38.6% SNR increase for b=6000 s/mm2 (p=0.015). Using spherical harmonic reconstruction of the q-ball orientation distribution function at b=3000 s/mm2, 7T QBI allowed accurate visualization of crossing fiber tracts with fewer diffusion-encoding acquisitions than at 3T. The improvement of 7T QBI at b factors as high as 6000 s/mm2 resulted in better angular resolution than 3T for depicting fibers crossing at shallow angles. Although the increased susceptibility effects at 7T caused problematic distortions near brain-air interfaces at the skull base and posterior fossa, these initial 7T QBI studies demonstrated excellent quality in much of the supratentorial brain with significant improvements as compared to 3T acquisitions in the same individuals. PMID:17692489

  11. Recent RF Experiments and Application of RF Waves to Real-Time Control of Safety Factor Profile in JT-60U

    NASA Astrophysics Data System (ADS)

    Suzuki, T.; Isayama, A.; Ide, S.; Fujita, T.; Oikawa, T.; Sakata, S.; Sueoka, M.; Hosoyama, H.; JT-60 Team

    2005-09-01

    Two topics of applications of RF waves to current profile control in JT-60U are presented; application of lower-hybrid (LH) waves to safety factor profile control and electron cyclotron (EC) waves to neo-classical tearing mode (NTM) control. A real-time control system of safety factor (q) profile was developed. This system, for the first time, enables 1) real time evaluation of q profile using local magnetic pitch angle measurement by motional Stark effect (MSE) diagnostic and 2) control of current drive (CD) location (ρCD) by controlling the parallel refractive index N∥ of LH waves through control of phase difference (Δφ) of LH waves between multi-junction launcher modules. The method for real-time q profile evaluation was newly developed, without time-consuming reconstruction of equilibrium, so that the method requires less computational time. Safety factor profile by the real-time calculation agrees well with that by equilibrium reconstruction with MSE. The control system controls ρCD through Δφ in such a way to decrease the largest residual between the real-time evaluated q profile q(r) and its reference profile qref(r). The real-time control system was applied to a positive shear plasma (q(0)˜1). The reference q profile was set to monotonic positive shear profile having qref(0)=1.3. The real-time q profile approached to the qref(r) during application of real-time control, and was sustained for 3s, which was limited by the duration of the injected LH power. Temporal evolution of current profile was consistent with relaxation of inductive electric field induced by theoretical LH driven current. An m/n=3/2 NTM that appeared at βN˜3 was completely stabilized by ECCD applied to a fully-developed NTM. Precise ECCD at NTM island was essential for the stabilization. ECCD that was applied to resonant rational surface (q=3/2) before an NTM onset suppressed appearance of NTM. In order to keep NTM intensity below a level, ECCD before the mode onset was more effective than that after mode saturation.

  12. Prevalence of hypocalcaemia and its associated features in 22q11·2 deletion syndrome.

    PubMed

    Cheung, Evelyn Ning Man; George, Susan R; Costain, Gary A; Andrade, Danielle M; Chow, Eva W C; Silversides, Candice K; Bassett, Anne S

    2014-08-01

    22q11.2 deletion syndrome (22q11.2DS) is a relatively common yet under-recognized genetic syndrome that may present with endocrine features. We aimed to address the factors that contribute to the high prevalence of hypocalcaemia. We investigated hypocalcaemia in a well-characterized sample of 138 adults with 22q11.2DS (65 m, 73 F; mean age 34.2, SD 11.8, years) using laboratory studies and lifelong medical records. Logistic regression modelling was used to identify features associated with lifetime prevalence of hypocalcaemia. Of the total sample, 111 (80.4%) had a lifetime history of hypocalcaemia. Eleven (84.6%) of 13 subjects with neonatal hypocalcaemia had documented recurrence of hypocalcaemia. Lifetime history of hypocalcaemia was associated with lifetime prevalence of hypoparathyroidism (P < 0.0001) and hypothyroidism (P = 0.04), as statistically independent factors. Hypomagnesaemia was associated with concurrent hypocalcaemic measurements, especially in the presence of concurrent hypoparathyroidism (P = 0.02). The results suggest that, in addition to the major effect of hypoparathyroidism, hypothyroidism may play a role in hypocalcaemia in 22q11.2DS and that there is a high recurrence rate of neonatal hypocalcaemia. Hypomagnesaemia may contribute to hypocalcaemia by further suppressing parathyroid hormone (PTH). Although further studies are needed, the findings support regular lifelong follow-up of calcium, magnesium, PTH and TSH levels in patients with 22q11.2DS. At any age, hypocalcaemia with hypoparathyroidism and/or hypothyroidism may suggest a diagnosis of 22q11.2DS. © 2014 The Authors. Clinical Endocrinology published by John Wiley & Sons Ltd.

  13. Electromagnetically induced transparency with hybrid silicon-plasmonic traveling-wave resonators

    NASA Astrophysics Data System (ADS)

    Ketzaki, Dimitra A.; Tsilipakos, Odysseas; Yioultsis, Traianos V.; Kriezis, Emmanouil E.

    2013-09-01

    Spectral filtering and electromagnetically induced transparency (EIT) with hybrid silicon-plasmonic traveling-wave resonators are theoretically investigated. The rigorous three-dimensional vector finite element method simulations are complemented with temporal coupled mode theory. We show that ring and disk resonators with sub-micron radii can efficiently filter the lightwave with minimal insertion loss and high quality factors (Q). It is shown that disk resonators feature reduced radiation losses and are thus advantageous. They exhibit unloaded quality factors as high as 1000 in the telecom spectral range, resulting in all-pass filtering components with sharp resonances. By cascading two slightly detuned resonators and providing an additional route for resonator interaction (i.e., a second bus waveguide), a response reminiscent of EIT is observed. The EIT transmission peak can be shaped by means of resonator detuning and interelement separation. Importantly, the respective Q can become higher than that of the single-resonator structure. Thus, the possibility of exploiting this peak in switching applications relying on the thermo-optic effect is, finally, assessed.

  14. Characterization of noncontact piezoelectric transducer with conically shaped piezoelement

    NASA Technical Reports Server (NTRS)

    Williams, James H., Jr.; Ochi, Simeon C. U.

    1988-01-01

    The characterization of a dynamic surface displacement transducer (IQI Model 501) by a noncontact method is presented. The transducer is designed for ultrasonic as well as acoustic emission measurements and, according to the manufacturer, its characteristic features include a flat frequency response range which is from 50 to 1000 kHz and a quality factor Q of less than unity. The characterization is based on the behavior of the transducer as a receiver and involves exciting the transducer directly by transient pulse input stress signals of quasi-electrostatic origin and observing its response in a digital storage oscilloscope. Theoretical models for studying the response of the transducer to pulse input stress signals and for generating pulse stress signals are presented. The characteristic features of the transducer which include the central frequency f sub o, quality factor Q, and flat frequency response range are obtained by this noncontact characterization technique and they compare favorably with those obtained by a tone burst method which are also presented.

  15. Effect of surface roughness on liquid property measurements using mechanically oscillating sensors

    NASA Technical Reports Server (NTRS)

    Jain, Mahaveer K.; Grimes, Craig A.

    2002-01-01

    The resonant frequency and quality factor Q of a liquid immersed magnetoelastic sensor are shown to shift linearly with the liquid viscosity and density product. Measurements using different grade oils, organic chemicals, and glycerol-water mixtures show that the surface roughness of the sensor in combination with the molecular size of the liquid play important roles in determining measurement sensitivity, which can be controlled through adjusting the surface roughness of the sensor surface. A theoretical model describing the sensor resonant frequency and quality factor Q as a function of liquid properties is developed using a novel equivalent circuit approach. Experimental results are in agreement with theory when the liquid molecule size is larger than the average surface roughness. However, when the molecular size of the liquid is small relative to the surface roughness features molecules are trapped, and the trapped molecules act both as a mass load and viscous load; the result is higher viscous damping of the sensor than expected. c2002 Elsevier Science B.V. All rights reserved.

  16. [Confusing the confused: thoughts on impact factor, h(irsch) index, Q value, and other cofactors that influence the researcher's happiness].

    PubMed

    Quindós, Guillermo

    2009-06-30

    The need to evaluate curricula for sponsorship for research projects or professional promotion, has led to the search for tools that allow an objective valuation. However, the total number papers published, or citations of articles of a particular author, or the impact factor of the Journal where they are published are inadequate indicators for the evaluation of the quality and productivity of researchers. The h index, proposed by Hirsch, categorises the papers according to the number of citations per article. This tool appears to lack the limitations of other bibliometric tools but is less useful for non English-speaking authors. To propose and debate the usefulness of the existing bibliometric indicators and tools for the evaluation and categorization of researchers and scientific journals. Search for papers on bibliometric tools. There are some hot spots in the debate on the national and international evaluation of researchers' productivity and quality of scientific journals. Opinions on impact factors and h index have been discussed. The positive discrimination, using the Q value, is proposed as an alternative for the evaluation of Spanish and Iberoamerican researchers. It is very important de-mystify the importance of bibliometric indicators. The impact factor is useful for evaluating journals from the same scientific area but not for the evaluation of researchers' curricula. For the comparison of curricula from two or more researchers, we must use the h index or the proposed Q value. the latter allows positive discrimination of the task for Spanish and Iberoamerican researchers.

  17. The perturbation correction factors for cylindrical ionization chambers in high-energy photon beams.

    PubMed

    Yoshiyama, Fumiaki; Araki, Fujio; Ono, Takeshi

    2010-07-01

    In this study, we calculated perturbation correction factors for cylindrical ionization chambers in high-energy photon beams by using Monte Carlo simulations. We modeled four Farmer-type cylindrical chambers with the EGSnrc/Cavity code and calculated the cavity or electron fluence correction factor, P (cav), the displacement correction factor, P (dis), the wall correction factor, P (wall), the stem correction factor, P (stem), the central electrode correction factor, P (cel), and the overall perturbation correction factor, P (Q). The calculated P (dis) values for PTW30010/30013 chambers were 0.9967 +/- 0.0017, 0.9983 +/- 0.0019, and 0.9980 +/- 0.0019, respectively, for (60)Co, 4 MV, and 10 MV photon beams. The value for a (60)Co beam was about 1.0% higher than the 0.988 value recommended by the IAEA TRS-398 protocol. The P (dis) values had a substantial discrepancy compared to those of IAEA TRS-398 and AAPM TG-51 at all photon energies. The P (wall) values were from 0.9994 +/- 0.0020 to 1.0031 +/- 0.0020 for PTW30010 and from 0.9961 +/- 0.0018 to 0.9991 +/- 0.0017 for PTW30011/30012, in the range of (60)Co-10 MV. The P (wall) values for PTW30011/30012 were around 0.3% lower than those of the IAEA TRS-398. Also, the chamber response with and without a 1 mm PMMA water-proofing sleeve agreed within their combined uncertainty. The calculated P (stem) values ranged from 0.9945 +/- 0.0014 to 0.9965 +/- 0.0014, but they are not considered in current dosimetry protocols. The values were no significant difference on beam qualities. P (cel) for a 1 mm aluminum electrode agreed within 0.3% with that of IAEA TRS-398. The overall perturbation factors agreed within 0.4% with those for IAEA TRS-398.

  18. Efficacy and Safety of Tabalumab, an Anti-B-Cell-Activating Factor Monoclonal Antibody, in a Heterogeneous Rheumatoid Arthritis Population: Results From a Randomized, Placebo-Controlled, Phase 3 Trial (FLEX-O).

    PubMed

    Genovese, Mark C; Silverman, Gregg J; Emery, Paul; Gupta, Ramesh C; Gill, Anne; Veenhuizen, Melissa; Xie, Li; Komocsar, Wendy J; Berclaz, Pierre-Yves; Lee, Chin

    2015-08-01

    The efficacy and safety of 2 different dosing regimens of tabalumab, a monoclonal antibody that neutralizes membrane-bound and soluble B-cell-activating factor (BAFF), were evaluated in patients with rheumatoid arthritis. In this phase 3, multicenter, randomized study, 1004 patients (intention-to-treat population) received subcutaneous 120 mg tabalumab every 4 weeks (120/Q4W), 90 mg tabalumab every 2 weeks (90/Q2W), or placebo over 24 weeks. At baseline, a loading dose double the planned dose (ie, 240 mg, 180 mg, or placebo) was administered. Efficacy analyses were based on a prespecified subset of patients with 5 or more of 68 tender and 5 or more of 66 swollen joints at baseline (efficacy population, n = 849). The primary efficacy end point was ACR20 (20% improvement in American College of Rheumatology criteria) response at week 24. At week 24, there were no differences in ACR20 response rates (120/Q4W = 34.4%, 90/Q2W = 33.5%, placebo = 31.5%) or any other measures of efficacy across the treatment groups. Discontinuations due to adverse events (AE) were 3.4%, 2.7%, and 4.0%; incidence of treatment-emergent AEs were 64.1%, 58.2%, and 58.8%, with 23.2%, 25.9%, and 22.0% treatment-emergent infections; and incidence rates of serious AEs were 3.7%, 2.2%, and 2.8% with 1.1%, 0.3%, and 0.7% serious infections in the 120/Q4W, 90/Q2W, and placebo groups, respectively. Three deaths were reported (120/Q4W, n = 2; 90/Q2W, n = 1). Each tabalumab group had significant decreases versus placebo in CD3-CD20 B cells (P ≤ 0.05) and in serum immunoglobulins (P ≤ 0.001). Although tabalumab administration resulted in biologic activity, as demonstrated by changes in B cells and immunoglobulins, targeting BAFF-dependent pathways alone is not sufficient to significantly reduce rheumatoid arthritis disease activity.

  19. Detection of chromosomal abnormalities and the 22q11 microdeletion in fetuses with congenital heart defects.

    PubMed

    Lv, Wei; Wang, Shuyu

    2014-11-01

    Chromosomal abnormalities and the 22q11 microdeletion are implicated in congenital heart defects (CHDs). This study was designed to detect these abnormalities in fetuses and determine the effect of genetic factors on CHD etiology. Between January 2010 and December 2011, 113 fetuses with CHD treated at the Beijing Obstetrics and Gynecology Hospital were investigated, using chromosome karyotyping of either amniotic fluid cell or umbilical cord blood cell samples. Fetuses with a normal result were then investigated for the 22q11 microdeletion by fluorescence in situ hybridization. Of the 113 patients, 12 (10.6%) exhibited chromosomal abnormalities, while 6 (5.3%) of the remaining 101 cases presented with a 22q11 microdeletion. The incidence of chromosomal abnormalities was significantly higher in the group of fetuses presenting with extracardiac malformations in addition to CHD (P<0.001), although the detection of the 22q11 microdeletion was not significantly different between the two groups (P=0.583). In addition, all fetuses with the 22q11 microdeletion occurred de novo. In conclusion, genetic factors are important in the etiology of CHD. Where fetuses present with cardiac defects, additional chromosomal analysis is required to detect extracardiac abnormalities. Fetuses with heart defects should also be considered for 22q11 microdeletion detection to evaluate fetal prognosis, particularly prior to surgery.

  20. Angular distribution of cosmological parameters as a probe of inhomogeneities: a kinematic parametrisation

    NASA Astrophysics Data System (ADS)

    Carvalho, C. Sofia; Basilakos, Spyros

    2016-08-01

    We use a kinematic parametrisation of the luminosity distance to measure the angular distribution on the sky of time derivatives of the scale factor, in particular the Hubble parameter H0, the deceleration parameter q0, and the jerk parameter j0. We apply a recently published method to complement probing the inhomogeneity of the large-scale structure by means of the inhomogeneity in the cosmic expansion. This parametrisation is independent of the cosmological equation of state, which renders it adequate to test interpretations of the cosmic acceleration alternative to the cosmological constant. For the same analytical toy model of an inhomogeneous ensemble of homogenous pixels, we derive the backreaction term in j0 due to the fluctuations of { H0,q0 } and measure it to be of order 10-2 times the corresponding average over the pixels in the absence of backreaction. In agreement with that computed using a ΛCDM parametrisation of the luminosity distance, the backreaction effect on q0 remains below the detection threshold. Although the backreaction effect on j0 is about ten times that on q0, it is also below the detection threshold. Hence backreaction remains unobservable both in q0 and in j0.

  1. Comparisons of Integrated Radiation Transport Models with Microdosimetry Data in Spaceflight

    NASA Technical Reports Server (NTRS)

    Cucinotta, Francis A.; Nikjoo, H.; Kim, M. Y.; Hu, X.; Dicello, J. F.; Pisacane, V. L.

    2006-01-01

    Astronauts are exposed to galactic cosmic rays (GCR), trapped protons, and possible solar particle events (SPE) during spaceflight. For such complicated mixtures of radiation types and kinetic energies, tissue equivalent proportional counters (TEPC's) represent a simple time-dependent approach for radiation monitoring. Of interest in radiation protection is the average quality factor of a radiation field defined as a function of linear energy transfer, LET, Q(sub ave)(LET). However TEPC's measure the average quality factors as a function of lineal energy (y), Q(sub ave)(y) defined as the average energy deposition in a volume divided by the average chord length of the volume. Lineal energy, y deviates from LET due to energy straggling, delta-ray escape or entry, and nuclear fragments produced in the detector. Using integrated space radiation models that includes the transport code HZETRN/BRYNTRN, the quantum nuclear interaction model, QMSFRG, and results from Monte-Carlo track simulations of TEPC's response to ions, we consider comparisons of model calculations to TEPC results from NASA missions in low Earth orbit and make predictions for lunar and Mars missions. Good agreement between the model and measured spectra from past NASA missions is found. A finding of this work is that TEPC's values for trapped or solar protons of Q(sub ave)(y) range from 1.9-2.5, overestimating Q(sub ave)(LET), which ranges from 1.4-1.6 with both quantities increasing with shielding depth due to nuclear secondaries Comparisons for the complete GCR spectra show that Q(sub ave)(LET) for GCR is approximately 3.5-4.5, while TEPC's measure 2.9-3.4 for Q(sub ave)(y) with the GCR values decreasing with depth as heavy ions are absorbed in shielding material. Our results support the use of TEPC's for space radiation environmental monitoring when computational analysis is used for proper data interpretation.

  2. Microcavity morphology optimization

    NASA Astrophysics Data System (ADS)

    Ferdous, Fahmida; Demchenko, Alena A.; Vyatchanin, Sergey P.; Matsko, Andrey B.; Maleki, Lute

    2014-09-01

    High spectral mode density of conventional optical cavities is detrimental to the generation of broad optical frequency combs and to other linear and nonlinear applications. In this work we optimize the morphology of high-Q whispering gallery (WG) and Fabry-Perot (FP) cavities and find a set of parameters that allows treating them, essentially, as single-mode structures, thus removing limitations associated with a high density of cavity mode spectra. We show that both single-mode WGs and single-mode FP cavities have similar physical properties, in spite of their different loss mechanisms. The morphology optimization does not lead to a reduction of quality factors of modes belonging to the basic family. We study the parameter space numerically and find the region where the highest possible Q factor of the cavity modes can be realized while just having a single bound state in the cavity. The value of the Q factor is comparable with that achieved in conventional cavities. The proposed cavity structures will be beneficial for generation of octave spanning coherent frequency combs and will prevent undesirable effects of parametric instability in laser gravitational wave detectors.

  3. Discrimination and identification of Q-markers based on 'Spider-web' mode for quality control of traditional Chinese medicine.

    PubMed

    Jiang, Zhenzuo; Yang, Jing; Wang, Yuefei

    2017-12-28

    The safety and effectiveness of traditional Chinese medicine (TCM) in clinical practice is directly related to the quality of TCM. And, the quality control of TCM is a pivotal issue to the quality of TCM, but also an obstacle impeding the modernization of TCM. The purpose of this work is to compile and develop a strategy based on discrimination and identification of quality markers (Q-markers) for quality control of TCM. Mainly established by seven variables derived from four dimensions including content, stability, pharmacokinetics and pharmacology, the 'Spider-web' mode was undertaken to assess the Q-marker property of candidate compounds originated from TCM by taking regression area (A) and coefficient variation (CV) of the tested compounds into account. The importance index (ImI), ImI = A × 1/CV, was suggested to focus Q-markers. The compounds with larger regression area (A) and less coefficient variation (CV) are preferentially adopted as Q-markers, which should possess the satisfactory properties of content, stability, pharmacokinetics and pharmacological activity. To the contrary, the compounds are excluded on the grounds of the unsatisfactory Q-markers' property, less regression area (A) and larger coefficient variation (CV), which cannot represent the quality of TCM. The 'Spider-web' mode can filter out the redundant constituents and focus on the key indexes of quality control - Q-markers. The screened Q-markers possess the optimal integrated properties of content, stability, pharmacokinetics and pharmacology among the numerous and complicated ingredients of TCM, which can comprehensively characterize inherent quality of TCM. In summary, the novel strategy established in this work provides a valuable perspective for the quality control of TCM. Copyright © 2017 Elsevier GmbH. All rights reserved.

  4. Frequency of cardiovascular diseases and risk factors treated in France according to social deprivation and residence in an overseas territory.

    PubMed

    Tuppin, Philippe; Ricci-Renaud, Pauline; de Peretti, Christine; Fagot-Campagna, Anne; Alla, François; Danchin, Nicolas; Allemand, Hubert

    2014-05-15

    The frequencies of treated cardiovascular disease (CVD) and their associated risk factors (CVRF) may vary according to socioeconomic and territorial characteristics. These frequencies have been described for 48million policyholders of the French general health insurance scheme, according to a metropolitan geographical deprivation index in five quintiles (from the least to the most deprived: Q1 to Q5), the existence of universal complementary health cover (CMUC) in individuals under the age of 60, and residence in a French overseas territory (FOT). The information system (SNIIRAM) was used to identify CVDs and anti-diabetic, anti-hypertensive or lipid-lowering treatments by three reimbursements in 2010. After age- and sex-specific adjustment, the inhabitants of the most deprived areas more often suffered from distal arterial disease (Q5/Q1=1.5), coronary artery disease (1.2) and cerebral vascular accident (1.1), as did the CMUC beneficiaries compared to non-beneficiaries (ratios of 1.7, 1.3 and 1.5), and the FOT residents in comparison to the most deprived metropolitan quintile (Q1), with the exception of coronary artery disease (1.2, 0.6 and 1.2). Inhabitants of the most deprived areas more often received anti-diabetic and anti-hypertensive treatment (Q5/Q1=1.4 and 1.2), as did the people on the CMUC (2.0 and 1.2) and the FOT inhabitants (FOT/Q1=2.4 and 1.3). These ratios were of 1.1, 1.0 and 0.8 for lipid-lowering drugs. These results pinpoint populations for which specific preventative initiatives could be supported. While health care service utilisation is facilitated (CMUC), it is probably not yet effective enough in view of the persistent increased cardiovascular risk. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  5. Evaluation of Military Field-Water Quality. Volume 2. Constituents of Military Concern from Natural and Anthropogenic Sources. Part 2. Pesticides

    DTIC Science & Technology

    1988-01-01

    Volume 2. Pt. 2 P" y ~ "q r4 I -V- "f CI Vý q- 8 , 9 .00 LO - (A ’e I=) 0- I I I N 1.0s 2 1 0 G 0 0 0 0 0 0"COIIM0 tOý 0 1 0 1 01 1 0 0C Z0 0 tn 0...Scofield, J. Kelly-Reif, F. Li, T. Awad, W. Malloch, P. Lessard, D. Hsieh 130. " Y -P1 00 IOfRT 13b TIME COVERED 14. OAT[ OF REPORT (YoeNI A Gato Dy) IS...suspected of being carcinogenic, and their ADI’ s are established at a very low level, representing the FAO’s judgments of an acceptably low cancer risk

  6. International Conference on Harmonisation; guidance on Q10 Pharmaceutical Quality System; availability. Notice.

    PubMed

    2009-04-08

    The Food and Drug Administration (FDA) is announcing the availability of a guidance entitled "Q10 Pharmaceutical Quality System." The guidance was prepared under the auspices of the International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH). The guidance describes a model for an effective quality management system for the pharmaceutical industry, referred to as the Pharmaceutical Quality System. The guidance is intended to provide a comprehensive approach to an effective pharmaceutical quality system that is based on International Organization for Standardization (ISO) concepts, includes applicable good manufacturing practice (GMP) regulations and complements ICH guidances on "Q8 Pharmaceutical Development" and "Q9 Quality Risk Management."

  7. Translation and Validation of the Nomophobia Questionnaire in the Italian Language: Exploratory Factor Analysis

    PubMed Central

    Argumosa-Villar, Lidia; Boada-Grau, Joan; Vigil-Colet, Andreu; Yildirim, Caglar; Del Puente, Giovanni; Watad, Abdulla

    2018-01-01

    Background Nomophobia, which is a neologism derived from the combination of “no mobile,” “phone,” and “phobia” is considered to be a modern situational phobia and indicates a fear of feeling disconnected. Objective No psychometric scales are available in Italian for investigating such a construct. We therefore planned a translation and validation study of the Nomophobia Questionnaire (NMP-Q), which is an instrument developed by Yildirim and Correia. Subjects were recruited via an online survey using a snowball approach. Methods The NMP-Q was translated from English into Italian using a classical “backwards and forwards” procedure. In order to explore the underlying factor structure of the translated questionnaire, an exploratory factor analysis was carried out. A principal component analysis approach with varimax rotation was performed. Multivariate regression analyses were computed to shed light on the psychological predictors of nomophobia. Results A sample of 403 subjects volunteered to take part in the study. The average age of participants was 27.91 years (standard deviation 8.63) and the sample was comprised of 160 males (160/403, 39.7%) and 243 females (243/403, 60.3%). Forty-five subjects spent less than 1 hour on their mobile phone per day (45/403, 11.2%), 94 spent between 1 and 2 hours (94/403, 23.3%), 69 spent between 2 and 3 hours (69/403, 17.1%), 58 spent between 3 and 4 hours (58/403, 14.4%), 48 spent between 4 and 5 hours (48/403, 11.9%), 29 spent between 5 and 7 hours (29/403, 7.2%), 36 spent between 7 and 9 hours (36/403, 8.9%), and 24 spent more than 10 hours (24/403, 6.0%). The eigenvalues and scree plot supported a 3-factorial nature of the translated questionnaire. The NMP-Q showed an overall Cronbach alpha coefficient of 0.95 (0.94, 0.89, and 0.88 for the three factors). The first factor explained up to 23.32% of the total variance, while the second and third factors explained up to 23.91% and 18.67% of the variance, respectively. The total NMP-Q score correlated with the number of hours spent on a mobile phone. Conclusions The Italian version of the NMP-Q proved to be reliable. PMID:29358161

  8. High-Q, in-plane modes of nanomechanical resonators operated in air

    NASA Astrophysics Data System (ADS)

    Waggoner, Philip S.; Tan, Christine P.; Bellan, Leon; Craighead, Harold G.

    2009-05-01

    Nanomechanical resonators have traditionally been limited to use in vacuum due to low quality factors that come as a result of viscous damping effects in air or liquid. We have fabricated arrays of 90 nm thick trampoline-shaped resonators, studied their resonant frequency spectrum as a function of pressure, and found that some high frequency modes exhibit quality factors over 2000 at atmospheric pressure. We have excited the in-plane resonances of these devices, verified their identities both experimentally and with finite element modeling, and demonstrated their advantageous characteristics for ambient sensing. Even after deposition of a relatively thick polymer layer, the in-plane resonant modes still boast quality factors on the order of 2000. These results show promise for the use of nanomechanical resonant sensors in real-time atmospheric sensing applications.

  9. Revisiting the rotating call schedule in less than 80 hours per week.

    PubMed

    Roses, Robert E; Foley, Paul J; Paulson, Emily C; Pray, Lori; Kelz, Rachel R; Williams, Noel N; Morris, Jon B

    2009-01-01

    The Accreditation Council for Graduate Medical Education (ACGME) work-hour restrictions have prompted many surgical training programs to adopt a night-float resident coverage system (NF). Dissatisfaction with NF prompted us to transition to a rotating junior resident call model (Q4) with 24-hour call shifts at the outset of the 2007-2008 academic year. We performed a prospective study to determine the influence of this transition on resident education, morale, and quality of life, as well as on ACGME work rule compliance and American Board of Surgery In-Training Examination (ABSITE) scores. Residents were surveyed after 1 year of NF and again 1 year after the introduction of Q4. Responses to a series of statements about the influence of the call model (NF or Q4) on educational opportunities and morale were solicited. The survey used a 5-point Likert response scale (1 = complete disagreement to 5 = complete agreement). Median values of participant responses were calculated and compared using the Wilcoxon rank-sum test. Compliance with ACGME work rules, ABSITE scores, and operative case logs from the 2006-2007 and 2007-2008 academic years were also compared. Residents were significantly more enthusiastic about Q4 compared with NF, particularly when asked about the influence these systems had on morale (median response = 4.0 [Q4] compared with 2.0 [NF]; p = 0.001) and engagement of residents by the teaching faculty (median response = 4.0 [Q4] compared with 1.0 [NF]; p = 0.001). Case logs revealed a similar operative experience for first-year residents irrespective of the call schedule (p = 0.51). Excellent compliance with ACGME work rules was maintained as reflected by the percentage of monthly 80-hour violations per resident months worked (3% [Q4] compared with 0.7% [NF]). No difference was observed in the ABSITE scores of first-year residents (a mean percentile point increase of 1 was found after the introduction of Q4). Educational opportunities, compliance with ACGME work rules, and ABSITE scores can be preserved despite a transition from NF to Q4. Residents greatly prefer a rotating call schedule.

  10. Characteristics of Low-q(a) Disruptions in the Compact Toroidal Hybrid

    NASA Astrophysics Data System (ADS)

    Pandya, M. D.; Archmiller, M. C.; Ennis, D. A.; Hartwell, G. J.; Maurer, D. A.

    2014-10-01

    Tokamak disruptions are dramatic events that lead to a sudden loss of plasma confinement. Disruptions that occur at low edge safety-factor, q (a) , limit the operation of tokamaks to q (a) >= 2 . The Compact Toroidal Hybrid (CTH) is a torsatron-tokamak hybrid with a helical field coil and vertical field coils to establish a stellartor equilibrium, while an ohmic coil induces plasma current. A feature of the CTH device is the ability to adjust the vacuum rotational transform, tvac (t =1/q ), by varying the ratio of current in the helical and toroidal field coils. The value of edge tvac can be varied from about 0.02 to 0.3 (qvac (a) ~ 50 to 3.3). Plasma discharges in CTH are routinely observed to operate with q (a) < 2 , and in some cases as low as q (a) ~ 1 . 1 . In CTH, low-q(a) disruptions are observed with a dominant m/n=3/2 precursor. The disruptivity of plasma discharges is over 80% when tvac (a) < 0 . 04 (qvac (a) < 25) and as tvac (a) is increased further, the disruptivity of the plasma discharges decreases. The disruptions are completely suppressed for tvac (a) > 0 . 07 (qvac (a) ~ 14) . This work is supported by US Department of Energy Grant No. DE-FG02-00ER54610.

  11. Observation of internal transport barrier in ELMy H-mode plasmas on the EAST tokamak

    NASA Astrophysics Data System (ADS)

    Yang, Y.; Gao, X.; Liu, H. Q.; Li, G. Q.; Zhang, T.; Zeng, L.; Liu, Y. K.; Wu, M. Q.; Kong, D. F.; Ming, T. F.; Han, X.; Wang, Y. M.; Zang, Q.; Lyu, B.; Li, Y. Y.; Duan, Y. M.; Zhong, F. B.; Li, K.; Xu, L. Q.; Gong, X. Z.; Sun, Y. W.; Qian, J. P.; Ding, B. J.; Liu, Z. X.; Liu, F. K.; Hu, C. D.; Xiang, N.; Liang, Y. F.; Zhang, X. D.; Wan, B. N.; Li, J. G.; Wan, Y. X.; EAST Team

    2017-08-01

    The internal transport barrier (ITB) has been obtained in ELMy H-mode plasmas by neutron beam injection and lower hybrid wave heating on the Experimental Advanced Superconducting Tokamak (EAST). The ITB structure has been observed in profiles of ion temperature, electron temperature, and electron density within ρ < 0.5. It was also observed that the ITB formation is stepwise. Due to the ITB formation, the confinement quality H 98y2 increases from 1 to 1.1 and the normalized beta, β N, increases from 1.5 to near 2. The fishbone activity observed during the ITB phase suggests the central safety factor q(0) ˜ 1. Transport coefficients are calculated by particle balance and power balance analysis, showing an obvious reduction after the ITB formation.

  12. Proof-of-principle demonstration of Nb 3Sn superconducting radiofrequency cavities for high Q 0 applications

    DOE PAGES

    Posen, S.; Liepe, M.; Hall, D. L.

    2015-02-23

    Many future particle accelerators require hundreds of superconducting radiofrequency (SRF) cavities operating with high duty factor. The large dynamic heat load of the cavities causes the cryogenic plant to make up a significant part of the overall cost of the facility. Our contribution can be reduced by replacing standard niobium cavities with ones coated with a low-dissipation superconductor such as Nb 3Sn. Here, we present results for single cell cavities coated with Nb 3Sn at Cornell. Five coatings were carried out, showing that at 4.2 K, high Q 0 out to medium fields was reproducible, resulting in an average quenchmore » field of 14 MV/m and an average 4.2 K Q 0 at quench of 8 x 10 9 . In each case, the peak surface magnetic field at quench was well above H c1, showing that it is not a limiting field in these cavities. Furthermore, the coating with the best performance had a quench field of 17 MV/m, exceeding gradient requirements for state-of-the-art high duty factor SRF accelerators. It is also shown that—taking into account the thermodynamic efficiency of the cryogenic plant—the 4.2 K Q 0 values obtained meet the AC power consumption requirements of state-of-the-art high duty factor accelerators, making this a proof-of-principle demonstration for Nb 3Sn cavities in future applications.« less

  13. The Temperature Sensitivity (Q10) of Soil Respiration: Controlling Factors and Spatial Prediction at Regional Scale Based on Environmental Soil Classes

    NASA Astrophysics Data System (ADS)

    Meyer, N.; Welp, G.; Amelung, W.

    2018-02-01

    The temperature sensitivity of heterotrophic soil respiration is crucial for modeling carbon dynamics but it is variable. Presently, however, most models employ a fixed value of 1.5 or 2.0 for the increase of soil respiration per 10°C increase in temperature (Q10). Here we identified the variability of Q10 at a regional scale (Rur catchment, Germany/Belgium/Netherlands). We divided the study catchment into environmental soil classes (ESCs), which we define as unique combinations of land use, aggregated soil groups, and texture. We took nine soil samples from each ESC (108 samples) and incubated them at four soil moisture levels and five temperatures (5-25°C). We hypothesized that Q10 variability is controlled by soil organic carbon (SOC) degradability and soil moisture and that ESC can be used as a widely available proxy for Q10, owing to differences in SOC degradability. Measured Q10 values ranged from 1.2 to 2.8 and were correlated with indicators of SOC degradability (e.g., pH, r = -0.52). The effect of soil moisture on Q10 was variable: Q10 increased with moisture in croplands but decreased in forests. The ESC captured significant parts of Q10 variability under dry (R2 = 0.44) and intermediate (R2 = 0.36) moisture conditions, where Q10 increased in the order cropland

  14. Psychometric properties of the SDM-Q-9 questionnaire for shared decision-making in multiple sclerosis: item response theory modelling and confirmatory factor analysis.

    PubMed

    Ballesteros, Javier; Moral, Ester; Brieva, Luis; Ruiz-Beato, Elena; Prefasi, Daniel; Maurino, Jorge

    2017-04-22

    Shared decision-making is a cornerstone of patient-centred care. The 9-item Shared Decision-Making Questionnaire (SDM-Q-9) is a brief self-assessment tool for measuring patients' perceived level of involvement in decision-making related to their own treatment and care. Information related to the psychometric properties of the SDM-Q-9 for multiple sclerosis (MS) patients is limited. The objective of this study was to assess the performance of the items composing the SDM-Q-9 and its dimensional structure in patients with relapsing-remitting MS. A non-interventional, cross-sectional study in adult patients with relapsing-remitting MS was conducted in 17 MS units throughout Spain. A nonparametric item response theory (IRT) analysis was used to assess the latent construct and dimensional structure underlying the observed responses. A parametric IRT model, General Partial Credit Model, was fitted to obtain estimates of the relationship between the latent construct and item characteristics. The unidimensionality of the SDM-Q-9 instrument was assessed by confirmatory factor analysis. A total of 221 patients were studied (mean age = 42.1 ± 9.9 years, 68.3% female). Median Expanded Disability Status Scale score was 2.5 ± 1.5. Most patients reported taking part in each step of the decision-making process. Internal reliability of the instrument was high (Cronbach's α = 0.91) and the overall scale scalability score was 0.57, indicative of a strong scale. All items, except for the item 1, showed scalability indices higher than 0.30. Four items (items 6 through to 9) conveyed more than half of the SDM-Q-9 overall information (67.3%). The SDM-Q-9 was a good fit for a unidimensional latent structure (comparative fit index = 0.98, root-mean-square error of approximation = 0.07). All freely estimated parameters were statistically significant (P < 0.001). All items presented standardized parameter estimates with salient loadings (>0.40) with the exception of item 1 which presented the lowest loading (0.26). Items 6 through to 8 were the most relevant items for shared decision-making. The SDM-Q-9 presents appropriate psychometric properties and is therefore useful for assessing different aspects of shared decision-making in patients with multiple sclerosis.

  15. Neurocognitive Functioning in Patients with 22q11.2 Deletion Syndrome: A Meta-Analytic Review.

    PubMed

    Moberg, Paul J; Richman, Mara J; Roalf, David R; Morse, Chelsea L; Graefe, Anna C; Brennan, Laura; Vickers, Kayci; Tsering, Wangchen; Kamath, Vidyulata; Turetsky, Bruce I; Gur, Ruben C; Gur, Raquel E

    2018-06-19

    The 22q11.2 deletion syndrome (22q11.2DS) is a known risk factor for development of schizophrenia and is characterized by a complex neuropsychological profile. To date, a quantitative meta-analysis examining cognitive functioning in 22q11.2DS has not been conducted. A systematic review of cross-sectional studies comparing neuropsychological performance of individuals with 22q11.2DS with age-matched healthy typically developing and sibling comparison subjects was carried out. Potential moderators were analyzed. Analyses included 43 articles (282 effects) that met inclusion criteria. Very large and heterogeneous effects were seen for global cognition (d = - 1.21) and in specific neuropsychological domains (intellectual functioning, achievement, and executive function; d range = - 0.51 to - 2.43). Moderator analysis revealed a significant role for type of healthy comparison group used (typically developing or siblings), demographics (age, sex) and clinical factors (externalizing behavior). Results revealed significant differences between pediatric and adult samples, with isolated analysis within the pediatric sample yielding large effects in several neuropsychological domains (intellectual functioning, achievement, visual memory; d range = - 0.56 to - 2.50). Large cognitive deficits in intellectual functioning and specific neuropsychological variables in individuals with 22q11.2DS represent a robust finding, but these deficits are influenced by several factors, including type of comparison group utilized, age, sex, and clinical status. These findings highlight the clinical relevance of characterizing cognitive functioning in 22q11.2DS and the importance of considering demographic and clinical moderators in future analyses.

  16. The fracture of boron fibre-reinforced 6061 aluminium alloy

    NASA Technical Reports Server (NTRS)

    Wright, M. A.; Welch, D.; Jollay, J.

    1979-01-01

    The fracture of 6061 aluminium alloy reinforced with unidirectional and cross-plied 0/90 deg, 0/90/+ or - 45 deg boron fibres has been investigated. The results have been described in terms of a critical stress intensity, K(Q). Critical stress intensity factors were obtained by substituting the failure stress and the initial crack length into the appropriate expression for K(Q). Values were obtained that depended on the dimensions of the specimens. It was therefore concluded that, for the size of specimen tested, the values of K(Q) did not reflect any basic materials property.

  17. Measurement of the generalized form factors near threshold via γ *p → nπ + at high Q 2

    DOE PAGES

    Park, K.; Adhikari, K. P.; Adikaram, D.; ...

    2012-03-26

    We report the first extraction of the pion-nucleon multipoles near the production threshold for the nπ + channel at relatively high momentum transfer (Q 2 up to 4.2 GeV 2). The dominance of the s-wave transverse multipole (E 0+), expected in this region, allowed us to access the generalized form factor G 1 within the light-cone sum rule (LCSR) framework as well as the axial form factor G A. The data analyzed in this work were collected by the nearly 4π CEBAF Large Acceptance Spectrometer (CLAS) using a 5.754-GeV electron beam on a proton target. The differential cross section andmore » the π-N multipole E 0+/G D were measured using two different methods, the LCSR and a direct multipole fit. The results from the two methods are found to be consistent and almost Q 2 independent.« less

  18. Travelling wave resonators fabricated with low-loss hydrogenated amorphous silicon

    NASA Astrophysics Data System (ADS)

    Lipka, Timo; Amthor, Julia; Trieu, Hoc Khiem; Müller, Jörg

    2013-05-01

    Low-loss hydrogenated amorphous silicon is employed for the fabrication of various planar integrated travelling wave resonators. Microring, racetrack, and disk resonators of different dimensions were fabricated with CMOS-compatible processes and systematically investigated. The key properties of notch filter ring resonators as extinction ratio, Q-factor, free spectral range, and the group refractive index were determined for resonators of varying radius, thereby achieving critically coupled photonic systems with high extinction ratios of about 20 dB for both polarizations. Racetrack resonators that are arranged in add/drop configuration and high quality factor microdisk resonators were optically characterized, with the microdisks exhibiting Q-factors of greater than 100000. Four-channel add/drop wavelength-division multiplexing filters that are based on cascaded racetrack resonators are studied. The design, the fabrication, and the optical characterization are presented.

  19. An Overexpressed Q Allele Leads to Increased Spike Density and Improved Processing Quality in Common Wheat (Triticum aestivum).

    PubMed

    Xu, Bin-Jie; Chen, Qing; Zheng, Ting; Jiang, Yun-Feng; Qiao, Yuan-Yuan; Guo, Zhen-Ru; Cao, Yong-Li; Wang, Yan; Zhang, Ya-Zhou; Zong, Lu-Juan; Zhu, Jing; Liu, Cai-Hong; Jiang, Qian-Tao; Lan, Xiu-Jin; Ma, Jian; Wang, Ji-Rui; Zheng, You-Liang; Wei, Yu-Ming; Qi, Peng-Fei

    2018-03-02

    Spike density and processing quality are important traits in modern wheat production and are controlled by multiple gene loci. The associated genes have been intensively studied and new discoveries have been constantly reported during the past few decades. However, no gene playing a significant role in the development of these two traits has been identified. In the current study, a common wheat mutant with extremely compact spikes and good processing quality was isolated and characterized. A new allele ( Q c1 ) of the Q gene (an important domestication gene) responsible for the mutant phenotype was cloned, and the molecular mechanism for the mutant phenotype was studied. Results revealed that Q c1 originated from a point mutation that interferes with the miRNA172-directed cleavage of Q transcripts, leading to its overexpression. It also reduces the longitudinal cell size of rachises, resulting in an increased spike density. Furthermore, Q c1 increases the number of vascular bundles, which suggests a higher efficiency in the transportation of assimilates in the spikes of the mutant than that of wild type. This accounts for the improved processing quality. The effects of Q c1 on spike density and wheat processing quality were confirmed by analyzing nine common wheat mutants possessing four different Q c alleles. These results deepen our understanding of the key roles of Q gene, and provide new insights for the potential application of Q c alleles in wheat quality breeding. Copyright © 2018 Xu et al.

  20. Neutron scattering on solitons in quasi-one-dimensional systems

    NASA Astrophysics Data System (ADS)

    Fedyanin, V. K.

    1983-05-01

    In the framework of the model of an ideal lattice gas of solitons, we obtain the following general formula for the dynamic neutron scattering form factor: S(q, w) = N¯S 1(q, w) , S(q, w) = {p‧(ν 0)δ 22}/{2πqZ 1h }f 2(qδ(ν 0 Here q = k‧ - k and w = E‧ - E are the neutron momentum and energy transfer, respectively, ν0 = wq-1, δ(ν) is the soliton width of velocity ν, p‧( ν0) = d p/d ν| ν0 , p(ν) is the soliton momentum, E(p(ν)) is the soliton energy, N¯ is the average number of solitons at θ = kδT = β-1 and is constructed from the soliton non-linear differential equations. The derivation of the formula is essentially based on (i) specific dependence of these solutions on ξ = x - vt, and (ii) generalization of the averaging over the soliton ensemble, proposed in ref. [1]. The specifi properties of the scattering spectra of polypeptides, DNA molecules and magnetics as functions of the temperature and interaction parameters and of external fields are discussed on the basis of this formula. The contribution to S(q, w) for “slow” solitons in magnetics has been calculated in [2, 3]. (For each concrete model the authors were forced to formulate anew the way of calculation, to assume the small size of ν, etc.)

  1. Genome-wide association analysis in East Asians identifies breast cancer susceptibility loci at 1q32.1, 5q14.3 and 15q26.1

    PubMed Central

    Cai, Qiuyin; Zhang, Ben; Sung, Hyuna; Low, Siew-Kee; Kweon, Sun-Seog; Lu, Wei; Shi, Jiajun; Long, Jirong; Wen, Wanqing; Choi, Ji-Yeob; Noh, Dong-Young; Shen, Chen-Yang; Matsuo, Keitaro; Teo, Soo-Hwang; Kim, Mi Kyung; Khoo, Ui Soon; Iwasaki, Motoki; Hartman, Mikael; Takahashi, Atsushi; Ashikawa, Kyota; Matsuda, Koichi; Shin, Min-Ho; Park, Min Ho; Zheng, Ying; Xiang, Yong-Bing; Ji, Bu-Tian; Park, Sue K.; Wu, Pei-Ei; Hsiung, Chia-Ni; Ito, Hidemi; Kasuga, Yoshio; Kang, Peter; Mariapun, Shivaani; Ahn, Sei Hyun; Kang, Han Sung; Chan, Kelvin Y. K.; Man, Ellen P. S.; Iwata, Hiroji; Tsugane, Shoichiro; Miao, Hui; Liao, Jiemin; Nakamura, Yusuke; Kubo, Michiaki; Delahanty, Ryan J.; Zhang, Yanfeng; Li, Bingshan; Li, Chun; Gao, Yu-Tang; Shu, Xiao-Ou; Kang, Daehee; Zheng, Wei

    2014-01-01

    In a three-stage genome-wide association study among East Asian women including 22,780 cases and 24,181 controls, we identified three novel genetic loci associated with breast cancer risk, including rs4951011 at 1q32.1 (in intron 2 of the ZC3H11A gene, P = 8.82 × 10−9), rs10474352 at 5q14.3 (near the ARRDC3 gene, P = 1.67 × 10−9), and rs2290203 at 15q26.1 (in intron 14 of the PRC1 gene, P = 4.25 × 10−8). These associations were replicated in European-ancestry populations including 16,003 cases and 41,335 controls (P = 0.030, 0.004, and 0.010, respectively). Data from the ENCODE project suggest that variants rs4951011 and rs10474352 may be located in an enhancer region and transcription factor binding sites, respectively. This study provides additional insights into the genetics and biology of breast cancer. PMID:25038754

  2. Genome-wide association analysis in East Asians identifies breast cancer susceptibility loci at 1q32.1, 5q14.3 and 15q26.1.

    PubMed

    Cai, Qiuyin; Zhang, Ben; Sung, Hyuna; Low, Siew-Kee; Kweon, Sun-Seog; Lu, Wei; Shi, Jiajun; Long, Jirong; Wen, Wanqing; Choi, Ji-Yeob; Noh, Dong-Young; Shen, Chen-Yang; Matsuo, Keitaro; Teo, Soo-Hwang; Kim, Mi Kyung; Khoo, Ui Soon; Iwasaki, Motoki; Hartman, Mikael; Takahashi, Atsushi; Ashikawa, Kyota; Matsuda, Koichi; Shin, Min-Ho; Park, Min Ho; Zheng, Ying; Xiang, Yong-Bing; Ji, Bu-Tian; Park, Sue K; Wu, Pei-Ei; Hsiung, Chia-Ni; Ito, Hidemi; Kasuga, Yoshio; Kang, Peter; Mariapun, Shivaani; Ahn, Sei Hyun; Kang, Han Sung; Chan, Kelvin Y K; Man, Ellen P S; Iwata, Hiroji; Tsugane, Shoichiro; Miao, Hui; Liao, Jiemin; Nakamura, Yusuke; Kubo, Michiaki; Delahanty, Ryan J; Zhang, Yanfeng; Li, Bingshan; Li, Chun; Gao, Yu-Tang; Shu, Xiao-Ou; Kang, Daehee; Zheng, Wei

    2014-08-01

    In a three-stage genome-wide association study among East Asian women including 22,780 cases and 24,181 controls, we identified 3 genetic loci newly associated with breast cancer risk, including rs4951011 at 1q32.1 (in intron 2 of the ZC3H11A gene; P=8.82×10(-9)), rs10474352 at 5q14.3 (near the ARRDC3 gene; P=1.67×10(-9)) and rs2290203 at 15q26.1 (in intron 14 of the PRC1 gene; P=4.25×10(-8)). We replicated these associations in 16,003 cases and 41,335 controls of European ancestry (P=0.030, 0.004 and 0.010, respectively). Data from the ENCODE Project suggest that variants rs4951011 and rs10474352 might be located in an enhancer region and transcription factor binding sites, respectively. This study provides additional insights into the genetics and biology of breast cancer.

  3. On the interface between perturbative and nonperturbative QCD

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deur, Alexandre; Brodsky, Stanley J.; de Teramond, Guy F.

    2016-04-04

    The QCD running couplingmore » $$\\alpha_s(Q^2)$$ sets the strength of the interactions of quarks and gluons as a function of the momentum transfer $Q$. The $Q^2$ dependence of the coupling is required to describe hadronic interactions at both large and short distances. In this article we adopt the light-front holographic approach to strongly-coupled QCD, a formalism which incorporates confinement, predicts the spectroscopy of hadrons composed of light quarks, and describes the low-$Q^2$ analytic behavior of the strong coupling $$\\alpha_s(Q^2)$$. The high-$Q^2$ dependence of the coupling $$\\alpha_s(Q^2)$$ is specified by perturbative QCD and its renormalization group equation. The matching of the high and low $Q^2$ regimes of $$\\alpha_s(Q^2)$$ then determines the scale $$Q_0$$ which sets the interface between perturbative and nonperturbative hadron dynamics. The value of $$Q_0$$ can be used to set the factorization scale for DGLAP evolution of hadronic structure functions and the ERBL evolution of distribution amplitudes. We discuss the scheme-dependence of the value of $$Q_0$$ and the infrared fixed-point of the QCD coupling. Our analysis is carried out for the $$\\bar{MS}$$, $$g_1$$, $MOM$ and $V$ renormalization schemes. Our results show that the discrepancies on the value of $$\\alpha_s$$ at large distance seen in the literature can be explained by different choices of renormalization schemes. Lastly, we also provide the formulae to compute $$\\alpha_s(Q^2)$$ over the entire range of space-like momentum transfer for the different renormalization schemes discussed in this article.« less

  4. Predictors of visual outcomes in patients with neovascular age-related macular degeneration treated with anti-vascular endothelial growth factor therapy: post hoc analysis of the VIEW studies.

    PubMed

    Lanzetta, Paolo; Cruess, Alan F; Cohen, Salomon Y; Slakter, Jason S; Katz, Todd; Sowade, Olaf; Zeitz, Oliver; Ahlers, Christiane; Mitchell, Paul

    2018-04-16

    Identify predictors for response to anti-vascular endothelial growth factor (VEGF) therapy in patients with neovascular (wet) age-related macular degeneration (nAMD). Retrospective, post hoc analysis of VIEW 1/2. Patients were randomized 1:1:1:1 to 0.5 mg intravitreal aflibercept (IVT-AFL) injection every 4 weeks (0.5q4); 2 mg IVT-AFL every 4 weeks (2q4); 2 mg IVT-AFL every 8 weeks (2q8) after an initial three injections at weeks 0, 4 and 8 or 0.5 mg intravitreal ranibizumab every 4 weeks (0.5q4). 1815 patients [IVT-AFL 2q4 (n = 613); IVT-AFL 2q8 (n = 607); ranibizumab 0.5q4 (n = 595)] were included. Baseline demographics/characteristics were evenly balanced. Younger age (49-69 years), lower visual acuity (VA) [10.0-≤45.0 Early Treatment Diabetic Retinopathy Study (ETDRS) letters] and smaller choroidal neovascularization (CNV) size [0.0-≤3.1 disc areas (DA)] at baseline were associated with the most vision gain (≥15 letters) over 52 weeks (all nominal p < 0.0001).Younger age, higher baseline VA (>64.0-≤83.0 letters) and smaller CNV size were associated with a VA ≥20/40 at week 52. Predominantly classic CNV at baseline (nominal p = 0.0007), older age (≥90 years), lower baseline VA (10.0-≤ 45.0 ETDRS letters) and larger CNV size (>10.1-≤32.6 DA) were all associated with a VA ≤20/200 at week 52 (all nominal p < 0.0001). Along with treatment (nominal p < 0.0001), lower VA (p = 0.0166) and smaller central retinal thickness (both nominal p = 0.0190) were predictors for dry retina development. Younger age, lower VA and smaller CNV size at baseline were all associated with greater vision gains over 52 weeks while younger age, higher VA and smaller CNV size at treatment start were more likely to achieve best-corrected VA 20/40 or better after a year's treatment, suggesting the benefit of early anti-VEGF treatment. © 2018 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  5. Quality of life in children with infantile hemangioma: a case control study.

    PubMed

    Wang, Chuan; Li, Yanan; Xiang, Bo; Xiong, Fei; Li, Kai; Yang, Kaiying; Chen, Siyuan; Ji, Yi

    2017-11-16

    Infantile hemangioma (IH) is the most common vascular tumor in children. It is controversial whether IHs has effects on the quality of life (QOL) in patients of whom IH poses no threat or potential for complication. Thus, we conducted this study to evaluate the q QOL in patients with IH and find the predictors of poor QOL. The PedsQL 4.0 Genetic Core Scales and the PedsQL family information form were administered to parents of children with IH and healthy children both younger than 2-year-old. The quality-of-life instrument for IH (IH-QOL) and the PedsQL 4.0 family impact module were administered to parents of children with IH. We compared the PedsQL 4.0 Genetic Core Scales (GCIS) scores of the two groups. Multiple step-wise regression analysis was used to determine factors that influenced QOL in children with IH and their parents. Except for physical symptom, we found no significant difference in GCIS between patient group and healthy group (P = 0.409). The internal reliability of IH-QOL was excellent with the Cronbach's alpha coefficient for summary scores being 0.76. Multiple step-wise regression analysis showed that the predictors of poor IH-QOL total scores were hemangioma size, location, and mother's education level. The predictors of poor FIM total scores were hemangioma location and father's education level. The predictors of poor GCIS total scores were children's age, hemangioma location and father's education level. The findings support the feasibility and reliability of the Chinese version of IH-QOL to evaluate the QOL in children with IH and their parents. Hemangioma size, location and education level of mother are important impact factors for QOL in children with IH and their parents.

  6. Quantum Discord in a Spin System with Symmetry Breaking

    NASA Astrophysics Data System (ADS)

    Tomasello, Bruno; Rossini, Davide; Hamma, Alioscia; Amico, Luigi

    2013-06-01

    We analyze the quantum discord Q throughout the low temperature phase diagram of the quantum XY model in transverse field. We first focus on the T = 0 order-disorder quantum phase transition QPT both in the symmetric ground state and in the symmetry broken one. Beside it, we highlight how Q displays clear anomalies also at a noncritical value of the control parameter inside the ordered phase, where the ground state is completely factorized. We evidence how the phenomenon is in fact of collective nature and displays universal features. We also study Q at finite temperature. We show that, close to the QPT, Q exhibits quantum-classical crossover of the system with universal scaling behavior. We evidence a nontrivial pattern of thermal correlations resulting from the factorization phenomenon.

  7. Quantum Discord in a Spin System with Symmetry Breaking

    NASA Astrophysics Data System (ADS)

    Tomasello, Bruno; Rossini, Davide; Hamma, Alioscia; Amico, Luigi

    2012-11-01

    We analyze the quantum discordQ throughout the low temperature phase diagram of the quantum XY model in transverse field. We first focus on the T = 0 order-disorder quantum phase transition QPT both in the symmetric ground state and in the symmetry broken one. Beside it, we highlight how Q displays clear anomalies also at a noncritical value of the control parameter inside the ordered phase, where the ground state is completely factorized. We evidence how the phenomenon is in fact of collective nature and displays universal features. We also study Q at finite temperature. We show that, close to the QPT, Q exhibits quantum-classical crossover of the system with universal scaling behavior. We evidence a nontrivial pattern of thermal correlations resulting from the factorization phenomenon.

  8. Quality of life, self-stigma, and hope in schizophrenia spectrum disorders: a cross-sectional study

    PubMed Central

    Vrbova, Kristyna; Prasko, Jan; Ociskova, Marie; Kamaradova, Dana; Marackova, Marketa; Holubova, Michaela; Grambal, Ales; Slepecky, Milos; Latalova, Klara

    2017-01-01

    Goals The aim of this study was to explore the quality of life, self-stigma, personality traits, and hope in patients with schizophrenia spectrum disorders. Patients and methods A total of 52 outpatients participated in this cross-sectional study. The attending psychiatrist assessed each patient with Mini International Neuropsychiatric Interview (MINI). The patients then completed Quality of Life Satisfaction and Enjoyment Questionnaire (Q-LES-Q), Internalized Stigma of Mental Illness (ISMI) Scale, Temperament and Character Inventory – Revised (TCI-R), Adult Dispositional Hope Scale (ADHS), Drug Attitude Inventory 10 (DAI-10), and Liebowitz Social Anxiety Scale (LSAS)-Self-report. The psychiatrist evaluated Clinical Global Impression Severity – the objective version (objCGI-S), and the patients completed the Clinical Global Impression Severity – the subjective version (subjCGI-S). Each participant also completed Beck Depression Inventory-II (BDI-II), and Beck Anxiety Inventory (BAI). Results The quality of life was significantly higher in employed patients and individuals with higher hope, self-directedness (SD), and persistence (PS). The quality of life was lower among patients with higher number of psychiatric hospitalizations, those with higher severity of the disorder, and individuals who were taking higher doses of antipsychotics. Patients with more pronounced symptoms of depression, anxiety, and social anxiety had a lower quality of life. Finally, the quality of life was lower among individuals with higher harm avoidance (HA) and self-stigmatization (ISMI). Backward stepwise regression was applied to identify the most significant factors connected to self-stigma. The regression analysis showed that occupation, level of depression (BDI-II), attitude to using medication (DAI-10), social anxiety (LSAS), and antipsychotic index were the most relevant factors associated with lower quality of life. Conclusion Detection of the quality of life in the context of personality traits, hope, self-stigma, and demographic and clinical factors may be an important part of the assessment of the patient with schizophrenia. PMID:28260904

  9. Quality of life, self-stigma, and hope in schizophrenia spectrum disorders: a cross-sectional study.

    PubMed

    Vrbova, Kristyna; Prasko, Jan; Ociskova, Marie; Kamaradova, Dana; Marackova, Marketa; Holubova, Michaela; Grambal, Ales; Slepecky, Milos; Latalova, Klara

    2017-01-01

    The aim of this study was to explore the quality of life, self-stigma, personality traits, and hope in patients with schizophrenia spectrum disorders. A total of 52 outpatients participated in this cross-sectional study. The attending psychiatrist assessed each patient with Mini International Neuropsychiatric Interview (MINI). The patients then completed Quality of Life Satisfaction and Enjoyment Questionnaire (Q-LES-Q), Internalized Stigma of Mental Illness (ISMI) Scale, Temperament and Character Inventory - Revised (TCI-R), Adult Dispositional Hope Scale (ADHS), Drug Attitude Inventory 10 (DAI-10), and Liebowitz Social Anxiety Scale (LSAS)-Self-report. The psychiatrist evaluated Clinical Global Impression Severity - the objective version (objCGI-S), and the patients completed the Clinical Global Impression Severity - the subjective version (subjCGI-S). Each participant also completed Beck Depression Inventory-II (BDI-II), and Beck Anxiety Inventory (BAI). The quality of life was significantly higher in employed patients and individuals with higher hope, self-directedness (SD), and persistence (PS). The quality of life was lower among patients with higher number of psychiatric hospitalizations, those with higher severity of the disorder, and individuals who were taking higher doses of antipsychotics. Patients with more pronounced symptoms of depression, anxiety, and social anxiety had a lower quality of life. Finally, the quality of life was lower among individuals with higher harm avoidance (HA) and self-stigmatization (ISMI). Backward stepwise regression was applied to identify the most significant factors connected to self-stigma. The regression analysis showed that occupation, level of depression (BDI-II), attitude to using medication (DAI-10), social anxiety (LSAS), and antipsychotic index were the most relevant factors associated with lower quality of life. Detection of the quality of life in the context of personality traits, hope, self-stigma, and demographic and clinical factors may be an important part of the assessment of the patient with schizophrenia.

  10. Polarization observables and T-noninvariance in the weak charged current induced electron proton scattering

    NASA Astrophysics Data System (ADS)

    Fatima, A.; Sajjad Athar, M.; Singh, S. K.

    2018-06-01

    In this work, we have studied the total scattering cross section (σ, differential scattering cross section ( dσ/d Q2) as well as the longitudinal ( P_L(Ee,Q2)), perpendicular ( PP(Ee,Q2)), and transverse ( PT(Ee,Q2)) components of the polarization of the final hadron ( n, Λ and Σ0) produced in the electron proton scattering induced by the weak charged current. We have not assumed T-invariance which allows the transverse component of the hadron polarization perpendicular to the production plane to be non-zero. The numerical results are presented for all the above observables and their dependence on the axial vector form factor and the weak electric form factor are discussed. The present study enables the determination of the axial vector nucleon-hyperon transition form factors at high Q2 in the strangeness sector which can provide a test of the symmetries of the weak hadronic currents like T-invariance and SU(3) symmetry while assuming the hypothesis of conserved vector current and partial conservation of axial vector current.

  11. Apex-angle-dependent resonances in triangular split-ring resonators

    NASA Astrophysics Data System (ADS)

    Burnett, Max A.; Fiddy, Michael A.

    2016-02-01

    Along with other frequency selective structures (Pendry et al. in IEEE Trans Microw Theory Tech 47(11):2075-2084, 1999) (circles and squares), triangular split-ring resonators (TSRRs) only allow frequencies near the center resonant frequency to propagate. Further, TSRRs are attractive due to their small surface area (Vidhyalakshmi et al. in Stopband characteristics of complementary triangular split ring resonator loaded microstrip line, 2011), comparatively, and large quality factors ( Q) as previously investigated by Gay-Balmaz et al. (J Appl Phys 92(5):2929-2936, 2002). In this work, we examine the effects of varying the apex angle on the resonant frequency, the Q factor, and the phase shift imparted by the TSRR element within the GHz frequency regime.

  12. Enhanced Raman scattering of single nanoparticles in a high-Q whispering-gallery microresonator

    NASA Astrophysics Data System (ADS)

    Liu, Rui-Shan; Jin, Wei-Liang; Yu, Xiao-Chong; Liu, Yong-Chun; Xiao, Yun-Feng

    2015-04-01

    We study Raman scattering of single nanoparticles coupled to a high-Q whispering-gallery microresonator. It is found that cavity resonances greatly enhance the Raman signal, and the enhancement factor is as high as 108. Unlike the noncavity case, the signal power exhibits a nonmonotonic dependence on particle size, and it reaches the maximum when the Rayleigh scattering loss and the cavity intrinsic loss are comparable. We further analyze how the Raman signal intensity is influenced by different parameters including cavity quality factors and taper-cavity coupling strength. The detection limit of observing single-nanoparticle Raman signal is discussed finally. As a potential application, this mechanism may provide an alternative way to detect specific biological targets without the need of precovered biorecognitions.

  13. Properties of Superconducting Mo, Mo2n and Trilayer Mo2n-Mo-Mo2n Thin Films

    NASA Technical Reports Server (NTRS)

    Barrentine, E. M.; Stevenson, T. R.; Brown, A. D.; Lowitz, A. E.; Noroozian, O.; U-Yen, K.; Eshan, N.; Hsieh, W. T.; Moseley, S. H.; Wollack, E. J.

    2014-01-01

    We present measurements of the properties of thin film superconducting Mo, Mo2N and Mo2N/Mo/Mo2N trilayers of interest for microwave kinetic inductance detector (MKID) applications. Using microwave resonator devices, we investigate the transition temperature, energy gaps, kinetic inductance, and internal quality factors of these materials. We present an Usadel-based interpretation of the trilayer transition temperature as a function of trilayer thicknesses, and a 2-gap interpretation to understand the change in kinetic inductance and internal resonance quality factor (Q) as a function of temperature.

  14. High-dose chemotherapy for patients with high-risk breast cancer: a clinical and economic assessment using a quality-adjusted survival analysis.

    PubMed

    Marino, Patricia; Roché, Henri; Moatti, Jean-Paul

    2008-04-01

    The benefit of high-dose chemotherapy (HDC) has not been clearly demonstrated. It may offer disease-free survival improvement at the expense of major toxicity and increasing cost. We evaluated the trade-offs between toxicity, relapse, and costs using a quality-adjusted time without symptoms or toxicity (Q-TWiST) analysis. The analysis was conducted in the context of a randomized trial (PEGASE 01) evaluating the benefit of HDC for 314 patients with high-risk breast cancer. A Q-TWiST analysis was first performed to compare HDC with standard chemotherapy. We then used the results of this Q-TWiST analysis to inform a cost per quality-adjusted life-year (QALY) comparison between treatments. Q-TWiST durations were in favor of HDC, whatever the weighting coefficients used for the analysis. This benefit was significant when the weighting coefficient related to the time spent after relapse was low (<0.38). For quite high values of this coefficient (>0.78), HDC offered no benefit. For intermediate values, the results depended on the weighting coefficient attributed to the toxicity period. The incremental cost per QALY ranged from 12,691euro/QALY to 26,439euro/QALY, according to the coefficients used to weight toxicity and relapse. The benefits of HDC outweigh the burdens of treatment for a wide range of utility coefficients. Economic impact is not a barrier to HDC diffusion in this situation. Nevertheless, no significant benefit was demonstrated for a certain range of utility values.

  15. High-Q/V Monolithic Diamond Microdisks Fabricated with Quasi-isotropic Etching.

    PubMed

    Khanaliloo, Behzad; Mitchell, Matthew; Hryciw, Aaron C; Barclay, Paul E

    2015-08-12

    Optical microcavities enhance light-matter interactions and are essential for many experiments in solid state quantum optics, optomechanics, and nonlinear optics. Single crystal diamond microcavities are particularly sought after for applications involving diamond quantum emitters, such as nitrogen vacancy centers, and for experiments that benefit from diamond's excellent optical and mechanical properties. Light-matter coupling rates in experiments involving microcavities typically scale with Q/V, where Q and V are the microcavity quality-factor and mode-volume, respectively. Here we demonstrate that microdisk whispering gallery mode cavities with high Q/V can be fabricated directly from bulk single crystal diamond. By using a quasi-isotropic oxygen plasma to etch along diamond crystal planes and undercut passivated diamond structures, we create monolithic diamond microdisks. Fiber taper based measurements show that these devices support TE- and TM-like optical modes with Q > 1.1 × 10(5) and V < 11(λ/n) (3) at a wavelength of 1.5 μm.

  16. The Logarithmic Tail of Néel Walls

    NASA Astrophysics Data System (ADS)

    Melcher, Christof

    We study the multiscale problem of a parametrized planar 180° rotation of magnetization states in a thin ferromagnetic film. In an appropriate scaling and when the film thickness is comparable to the Bloch line width, the underlying variational principle has the form where the reduced stray-field operator Q approximates (-Δ)1/2 as the quality factor Q tends to zero. We show that the associated Néel wall profile u exhibits a very long logarithmic tail. The proof relies on limiting elliptic regularity methods on the basis of the associated Euler-Lagrange equation and symmetrization arguments on the basis of the variational principle. Finally we study the renormalized limit behavior as Q tends to zero.

  17. Internal friction of rocks and volatiles on the moon

    NASA Technical Reports Server (NTRS)

    Tittmann, B. R.; Housley, R. M.; Cirlin, E. H.

    1973-01-01

    Internal friction quality factors Q up to 2200 have been observed in a strongly outgassed terrestrial analog of lunar basalt. This was accomplished by successively cycling a bar shaped sample vibrating in its fundamental longitudinal mode at 15 kHz to higher and higher temperatures in a vacuum between 100 and 10 nanotorr. After each cycle, Q measured at room temperature in the vacuum was observed to decrease with time suggesting that gas reabsorption was taking place even at these low pressures. A study of the effect of exposing a sample to a variety of gases and vapors showed that of the volatiles most likely to be present in the lunar environment H2O was by far the most effective in lowering Q.

  18. Identification and quantification of virulence factors of enterotoxigenic Escherichia coli by high-resolution melting curve quantitative PCR.

    PubMed

    Wang, Weilan; Zijlstra, Ruurd T; Gänzle, Michael G

    2017-05-15

    Diagnosis of enterotoxigenic E. coli (ETEC) associated diarrhea is complicated by the diversity of E.coli virulence factors. This study developed a multiplex quantitative PCR assay based on high-resolution melting curves analysis (HRM-qPCR) to identify and quantify genes encoding five ETEC fimbriae related to diarrhea in swine, i.e. K99, F41, F18, F6 and K88. Five fimbriae expressed by ETEC were amplified in multiple HRM-qPCR reactions to allow simultaneous identification and quantification of five target genes. The assay was calibrated to allow quantification of the most abundant target gene, and validated by analysis of 30 samples obtained from piglets with diarrhea and healthy controls, and comparison to standard qPCR detection. The five amplicons with melting temperatures (Tm) ranging from 74.7 ± 0.06 to 80.5 ± 0.15 °C were well-separated by HRM-qPCR. The area of amplicons under the melting peak correlated linearly to the proportion of the template in the calibration mixture if the proportion exceeded 4.8% (K88) or <1% (all other amplicons). The suitability of the method was evaluated using 30 samples from weaned pigs aged 6-7 weeks; 14 of these animals suffered from diarrhea in consequence of poor sanitary conditions. Genes encoding fimbriae and enterotoxins were quantified by HRM-qPCR and/or qPCR. The multiplex HRM-qPCR allowed accurate analysis when the total gene copy number of targets was more than 1 × 10 5 / g wet feces and the HRM curves were able to simultaneously distinguish fimbriae genes in the fecal samples. The relative quantification of the most abundant F18 based on melting peak area was highly correlated (P < 0.001; r 2  = 0.956) with that of individual qPCR result but the correlation for less abundant fimbriae was much lower. The multiplex HRM assay identifies ETEC virulence factors specifically and efficiently. It correctly indicated the predominant fimbriae type and additionally provides information of presence/ absence of other fimbriae types and it could find broad applications for pathogen diagnosis.

  19. Direct measurement of Lorentz transformation with Doppler effects

    NASA Astrophysics Data System (ADS)

    Chen, Shao-Guang

    For space science and astronomy the fundamentality of one-way velocity of light (OWVL) is selfevident. The measurement of OWVL (distance/interval) and the clock synchronization with light-signal transfer make a logical circulation. This means that OWVL could not be directly measured but only come indirectly from astronomical method (Romer's Io eclipse and Bradley's sidereal aberration), furthermore, the light-year by definitional OWVL and the trigonometry distance with AU are also un-measurable. For to solve this problem two methods of clock synchronization were proposed: The direct method is that at one end of dual-speed transmissionline with single clock measure the arriving-time difference of longitudinal wave and transverse wave or ordinary light and extraordinary light, again to calculate the collective sending-time of two wave with Yang's /shear elastic-modulus ratio (E/k) or extraordinary/ordinary light refractive-index ratio (ne/no), which work as one earthquake-station with single clock measures first-shake time and the distance to epicenter; The indirect method is that the one-way wavelength l is measured by dual-counters Ca and Cb and computer's real-time operation of reading difference (Nb - Na) of two counters, the frequency f is also simultaneously measured, then l f is just OWVL. Therefore, with classical Newtonian mechanics and ether wave optics, OWVL can be measured in the Galileo coordinate system with an isotropic length unit (1889 international meter definition). Without any hypotheses special relativity can entirely establish on the metrical results. When a certain wavelength l is defined as length unit, foregoing measurement of one-way wavelength l will become as the measurement of rod's length. Let a rigidity-rod connecting Ca and Cb moves relative to lamp-house with velocity v, rod's length L = (Nb - Na) l will change follow v by known Doppler effect, i.e., L(q) =L0 (1+ (v/c) cos q), where L0 is the proper length when v= 0, v• r = v cos q, r is the unit vector from lamphouse point to counters. Or: L (0) L (pi) =L0 (1+(v/c)) L0 (1 - (v/c)) =L0 2 y2 =L2 Or: L ≡ [L(0)L(pi)]1/2 =L0 y , which y ≡ (1 - (v/c)2 )1/2 is just Fitzgerald-Lorentzian contraction-factor. Also, when a light-wave period p is defined as time unit, from Doppler's frequency-shift the count N with p of one period T of moving-clock is: T(q) = N(q) p = T0 /(1+(v/c) cos q) Or: T ≡ (T(0) T(pi))1/2 = T 0 /y , where T0 is the proper period when v = 0, which is just the moving-clock-slower effect. Let r from clock point to lamp-house ((v/c) symbol reverse), Doppler formula in the usual form is: f (q) = 1/T(q) = f0 (1 - (v/c) cos q). Therefore, Lorentz transformation is the square root average of positive and negative directions twice metrical results of Doppler's frequency-shift, which Doppler's once items ( positive and negative v/c ) are counteract only residual twice item (v/c)2 (relativity-factor). Then Lorentz transformation can be directly measured by Doppler's frequency-shift method. The half-life of moving mu-meson is statistical average of many particles, the usual explanation using relativity-factor y is correct. An airship moving simultaneously along contrary directions is impossible, which makes that the relativity-factor y and the twin-paradox are inexistent in the macroscopical movement. Thereby, in the navigations of airship or satellite only use the measurement of Doppler's frequency-shift but have no use for Lorentz transformation.

  20. High-Resolution Attenuation Model for Gujarat: State of Western India

    NASA Astrophysics Data System (ADS)

    Jaiswal, N.; Singh, C.; Prajapati, S.

    2016-12-01

    In India, Gujarat belongs to the highest seismicity zone other than Himalayan belts. It has suffered from great economic and social loss due to many large magnitude earthquakes in the past. Thus the area needs a special attention from the seismic hazard point of view. It is the state of intraplate earthquakes similar to New Madrid Seismic zone in the United States. In the present study we have prepared a Lg attenuation tomographic model for Gujarat. The study also employs the other complementary information to get a detailed understanding into the mechanisms of attenuation. It will be useful in seismic hazard risk study and in estimating the source parameters of earthquakes. The amplitude of Lg wave is sensitive to different tectonic structures like faults, mountains and ocean basins. It travels predominantly through the continental crust but does not travel across ocean basins. Fifteen earthquakes of Mb >5 recorded at 40 stations operated in the region are chosen for the initial LgQ measurement using the standard two-station method. Finally, 5 events with 70 high-quality inter-station paths are selected from 117 possible pairs that are (1) aligned approximately with the source and (2) separated enough to permit the use of the standard two-station method for LgQ estimation. By using these values of Q0 (1 Hz LgQ) as input, an inversion is performed to have a Lg Q model for the region. A drastic spatial variation in Q0 has been noticed across our study region. Kutch, Jamnagar area are characterized by lowest Q0 values (<50) and south-east region of Saurashtra peninsula shows high Q0 (>300). These variations could be correlated with thermal effects, petrophysical properties and heterogeneity present in the crust.

Top