Sample records for quality high intensity

  1. [Quality assurance and quality management in intensive care].

    PubMed

    Notz, K; Dubb, R; Kaltwasser, A; Hermes, C; Pfeffer, S

    2015-11-01

    Treatment success in hospitals, particularly in intensive care units, is directly tied to quality of structure, process, and outcomes. Technological and medical advancements lead to ever more complex treatment situations with highly specialized tasks in intensive care nursing. Quality criteria that can be used to describe and correctly measure those highly complex multiprofessional situations have only been recently developed and put into practice.In this article, it will be shown how quality in multiprofessional teams can be definded and assessed in daily clinical practice. Core aspects are the choice of a nursing theory, quality assurance measures, and quality management. One possible option of quality assurance is the use of standard operating procedures (SOPs). Quality can ultimately only be achieved if professional groups think beyond their boundaries, minimize errors, and establish and live out instructions and SOPs.

  2. In their own words: Patients and families define high-quality palliative care in the intensive care unit*

    PubMed Central

    Nelson, Judith E.; Puntillo, Kathleen A.; Pronovost, Peter J.; Walker, Amy S.; McAdam, Jennifer L.; Ilaoa, Debra; Penrod, Joan

    2011-01-01

    Objective Although the majority of hospital deaths occur in the intensive care unit and virtually all critically ill patients and their families have palliative needs, we know little about how patients and families, the most important “stakeholders,” define high-quality intensive care unit palliative care. We conducted this study to obtain their views on important domains of this care. Design Qualitative study using focus groups facilitated by a single physician. Setting A 20-bed general intensive care unit in a 382-bed community hospital in Oklahoma; 24-bed medical–surgical intensive care unit in a 377-bed tertiary, university hospital in urban California; and eight-bed medical intensive care unit in a 311-bed Veterans’ Affairs hospital in a northeastern city. Patients Randomly-selected patients with intensive care unit length of stay ≥5 days in 2007 to 2008 who survived the intensive care unit, families of survivors, and families of patients who died in the intensive care unit. Interventions None. Measurements and Main Results Focus group facilitator used open-ended questions and scripted probes from a written guide. Three investigators independently coded meeting transcripts, achieving consensus on themes. From 48 subjects (15 patients, 33 family members) in nine focus groups across three sites, a shared definition of high-quality intensive care unit palliative care emerged: timely, clear, and compassionate communication by clinicians; clinical decision-making focused on patients’ preferences, goals, and values; patient care maintaining comfort, dignity, and personhood; and family care with open access and proximity to patients, interdisciplinary support in the intensive care unit, and bereavement care for families of patients who died. Participants also endorsed specific processes to operationalize the care they considered important. Conclusions Efforts to improve intensive care unit palliative care quality should focus on domains and processes that

  3. [Quality management in intensive care medicine].

    PubMed

    Martin, J; Braun, J-P

    2014-02-01

    Treatment of critical ill patients in the intensive care unit is tantamount to well-designed risk or quality management. Several tools of quality management and quality assurance have been developed in intensive care medicine. In addition to external quality assurance by benchmarking with regard to the intensive care medicine, peer review procedures have been established for external quality assurance in recent years. In the process of peer review of an intensive care unit (ICU), external physicians and nurses visit the ICU, evaluate on-site proceedings, and discuss with the managing team of the ICU possibilities for optimization. Furthermore, internal quality management in the ICU is possible based on the 10 quality indicators of the German Interdisciplinary Society for Intensive Care Medicine (DIVI, "Deutschen Interdisziplinären Vereinigung für Intensiv- und Notfallmedizin"). Thereby every ICU has numerous possibilities to improve their quality management system.

  4. [Quality management in intensive care medicine].

    PubMed

    Martin, J; Braun, J-P

    2013-09-01

    Treatment of critical ill patients in the intensive care unit is tantamount to well-designed risk or quality management. Several tools of quality management and quality assurance have been developed in intensive care medicine. In addition to extern quality assurance by benchmarking with regard to the intensive care medicine, peer review procedures have been established for external quality assurance in recent years. In the process of peer review of an intensive care unit (ICU), external physicians and nurses visit the ICU, evaluate on-site proceedings, and discuss with the managing team of the ICU possibilities for optimization. Furthermore, internal quality management in the ICU is possible based on the 10 quality indicators of the German Interdisciplinary Society for Intensive Care Medicine (DIVI, "Deutschen Interdisziplinären Vereinigung für Intensiv- und Notfallmedizin"). Thereby every ICU has numerous possibilities to improve their quality management system.

  5. Regional variations in health care intensity and physician perceptions of quality of care.

    PubMed

    Sirovich, Brenda E; Gottlieb, Daniel J; Welch, H Gilbert; Fisher, Elliott S

    2006-05-02

    Research has documented dramatic differences in health care utilization and spending across U.S. regions with similar levels of patient illness. Although patient outcomes and quality of care have been found to be no better in regions of high health care intensity, it is unknown whether physicians in these regions feel more capable of providing good patient care than those in low-intensity regions. To determine whether physicians in high-intensity regions feel better able to care for patients than physicians in low-intensity regions. Physician telephone survey. 51 metropolitan and 9 nonmetropolitan areas of the United States and a supplemental national sample. 10,577 physicians who provided care to adults in 1998 or 1999 were surveyed for the Community Tracking Study (response rate, 61%). The End-of-Life Expenditure Index, a measure of spending that reflects differences in the overall quantity of medical services provided rather than differences in illness or price, was used to determine health care intensity in the physicians' community. Outcomes included physicians' perceived availability of clinical services, ability to provide high-quality care to patients, and career satisfaction. Although the highest-intensity regions have substantially more hospital beds and specialists per capita, physicians in these regions reported more difficulty obtaining needed services for their patients. The proportion of physicians who felt able to obtain elective hospital admissions ranged from 50% in high-intensity regions to 64% in the lowest-intensity region (P < 0.001 for the relationship between intensity and perceived ability to obtain hospital admissions); the proportion of physicians who felt able to obtain high-quality specialist referrals ranged from 64% in high-intensity regions to 79% in low-intensity regions (P < 0.001). Compared with low-intensity regions, fewer physicians in high-intensity regions felt able to maintain good ongoing patient relationships (range, 62% to

  6. [Quality assurance in intensive care: the situation in Switzerland].

    PubMed

    Frutiger, A

    1999-10-30

    The movement for quality in medicine is starting to take on the dimensions of a crusade. Quite logically it has also reached the intensive care community. Due to their complex multidisciplinary functioning and because of the high costs involved, ICUs are model services reflecting the overall situation in our hospitals. The situation of Swiss intensive care is particularly interesting, because for over 25 years standards for design and staffing of Swiss ICUs have been in effect and were enforced via onsite visits by the Swiss Society of Intensive Care without government involvement. Swiss intensive care thus defined its structures long before the word "accreditation" had even been used in this context. While intensive care in Switzerland is practised in clearly defined, well equipped and adequately staffed units, much less is known about process quality and outcomes of these services. Statistics on admissions, length of stay and length of mechanical ventilation, as well as severity data based on a simple classification system, are collected nationwide and allow some limited insight into the overall process of care. Results of intensive care are not systematically assessed. In response to the constant threat of cost containment, Swiss ICUs should increasingly focus on process quality and results, while maintaining their existing good structures.

  7. Bereaved family member perceptions of quality of end-of-life care in U.S. regions with high and low usage of intensive care unit care.

    PubMed

    Teno, Joan M; Mor, Vincent; Ward, Nicholas; Roy, Jason; Clarridge, Brian; Wennberg, John E; Fisher, Elliott S

    2005-11-01

    To compare the quality of end-of-life care of persons dying in regions of differing practice intensity. Mortality follow-back survey. Geographic regions in the highest and lowest deciles of intensive care unit (ICU) use. Bereaved family member or other knowledgeable informants. Unmet needs, concerns, and rating of quality of end-of-life care in five domains (physical comfort and emotional support of the decedent, shared decision-making, treatment of the dying person with respect, providing information and emotional support to family members). Decedents in high- (n=365) and low-intensity (n=413) hospital service areas (HSAs) did not differ in age, sex, education, marital status, leading causes of death, or the degree to which death was expected, but those in the high-intensity ICU HSAs were more likely to be black and to live in nonrural areas. Respondents in high-intensity HSAs were more likely to report that care was of lower quality in each domain, and these differences were statistically significant in three of five domains. Respondents from high-intensity HSAs were more likely to report inadequate emotional support for the decedent (relative risk (RR)=1.2, 95% confidence interval (CI)=1.0-1.4), concerns with shared decision-making (RR=1.8, 95% CI=1.0-2.9), inadequate information about what to expect (RR=1.5, 95% CI=1.3-1.8), and failure to treat the decedent with respect (RR=1.4, 95% CI=1.0-1.9). Overall ratings of the quality of end-of-life care were also significantly lower in high-intensity HSAs. Dying in regions with a higher use of ICU care is not associated with improved perceptions of quality of end-of-life care.

  8. High-intensity Interval Training Frequency: Cardiometabolic Effects and Quality of Life.

    PubMed

    Stavrinou, Pinelopi S; Bogdanis, Gregory C; Giannaki, Christoforos D; Terzis, Gerasimos; Hadjicharalambous, Marios

    2018-02-01

    The effects of high intensity interval training (HIIT) frequency on cardiometabolic health and quality of life were examined in 35 healthy inactive adults (age: 31.7±2.6 yrs, VO 2 peak: 32.7±7.4 ml·: kg -1 ·: min -1 ). Participants were randomly assigned to a control (CON) and two training groups, which performed 10×60-s cycling at ~83% of peak power, two (HIIT-2) or three times per week (HIIT-3) for eight weeks. Compared with CON, both training regimes resulted in similar improvements in VO 2 peak (HIIT-2: 10.8%, p=0.048, HIIT-3: 13.6%, p=0.017), waist circumference (HIIT-2: -1.4 cm, p=0.048, HIIT-3: -2.4 cm, p=0.028), thigh cross-sectional area (HIIT-2: 11.4 cm 2 , p=0.001, HIIT-3: 9.3 cm 2 , p=0.001) and the physical health component of quality of life (HIIT-2: 8.4, p=0.001, HIIT-3: 12.2, p=0.001). However, HIIT-3 conferred additional health-related benefits by reducing total body and trunk fat percentage (p<0.05, compared with CON), total cholesterol and low-density lipoprotein-cholesterol (p<0.02, compared with CON) and by improving the mental component of quality of life (p=0.045, compared with CON). In conclusion, performing HIIT only twice per week is effective in promoting cardiometabolic health-related adaptations and quality of life in inactive adults. However, higher HIIT frequency is required for an effect on fat deposits, cholesterol and mental component of well-being. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Impact of High-flow Nasal Cannula Therapy in Quality Improvement and Clinical Outcomes in a Non-invasive Ventilation Device-free Pediatric Intensive Care Unit.

    PubMed

    Can, Fulva Kamit; Anil, Ayse Berna; Anil, Murat; Zengin, Neslihan; Bal, Alkan; Bicilioglu, Yuksel; Gokalp, Gamze; Durak, Fatih; Ince, Gulberat

    2017-10-15

    To analyze the change in quality indicators due to the use of high-flow nasal cannula therapy as a non-invasive ventilation method in children with respiratory distress/failure in a non-invasive ventilation device-free pediatric intensive care unit. Retrospective chart review of children with respiratory distress/failure admitted 1 year before (period before high-flow nasal cannula therapy) and 1 year after (period after high-flow nasal cannula therapy) the introduction of high-flow nasal cannula therapy. We compared quality indicators as rate of mechanical ventilation, total duration of mechanical ventilation, rate of re-intubation, pediatric intensive care unit length of stay, and mortality rate between these periods. Between November 2012 and November 2014, 272 patients: 141 before and 131 after high-flow nasal cannula therapy were reviewed (median age was 20.5 mo). Of the patients in the severe respiratory distress/failure subgroup, the rate of intubation was significantly lower in period after than in period before high-flow nasal cannula therapy group (58.1% vs. 76.1%; P <0.05). The median pediatric intensive care unit length of stay was significantly shorter in patients who did not require mechanical ventilation in the period after than in the period before high-flow nasal cannula therapy group (3d vs. 4d; P<0,05). Implementation of high-flow nasal cannula therapy in pediatric intensive care unit significantly improves the quality of therapy and its outcomes.

  10. Impact of Primary Care Intensive Management on High-Risk Veterans' Costs and Utilization: A Randomized Quality Improvement Trial.

    PubMed

    Yoon, Jean; Chang, Evelyn; Rubenstein, Lisa V; Park, Angel; Zulman, Donna M; Stockdale, Susan; Ong, Michael K; Atkins, David; Schectman, Gordon; Asch, Steven M

    2018-06-05

    Primary care models that offer comprehensive, accessible care to all patients may provide insufficient resources to meet the needs of patients with complex conditions who have the greatest risk for hospitalization. To assess whether augmenting usual primary care with team-based intensive management lowers utilization and costs for high-risk patients. Randomized quality improvement trial. (ClinicalTrials.gov: NCT03100526). 5 U.S. Department of Veterans Affairs (VA) medical centers. Primary care patients at high risk for hospitalization who had a recent acute care episode. Locally tailored intensive management programs providing care coordination, goals assessment, health coaching, medication reconciliation, and home visits through an interdisciplinary team, including a physician or nurse practitioner, a nurse, and psychosocial experts. Utilization and costs (including intensive management program expenses) 12 months before and after randomization. 2210 patients were randomly assigned, 1105 to intensive management and 1105 to usual care. Patients had a mean age of 63 years and an average of 7 chronic conditions; 90% were men. Of the patients assigned to intensive management, 487 (44%) received intensive outpatient care (that is, ≥3 encounters in person or by telephone) and 204 (18%) received limited intervention. From the pre- to postrandomization periods, mean inpatient costs decreased more for the intensive management than the usual care group (-$2164 [95% CI, -$7916 to $3587]). Outpatient costs increased more for the intensive management than the usual care group ($2636 [CI, $524 to $4748]), driven by greater use of primary care, home care, telephone care, and telehealth. Mean total costs were similar in the 2 groups before and after randomization. Sites took up to several months to contact eligible patients, limiting the time between treatment and outcome assessment. Only VA costs were assessed. High-risk patients with access to an intensive management program

  11. The effect of light intensity on image quality in endoscopic ear surgery.

    PubMed

    McCallum, R; McColl, J; Iyer, A

    2018-05-16

    Endoscopic ear surgery is a rapidly developing field with many advantages. But endoscopes can reach temperatures of over 110°C at the tip, raising safety concerns. Reducing the intensity of the light source reduces temperatures produced. However, quality of images at lower light intensities has not yet been studied. We set out to study the effect of light intensity on image quality in EES. Prospective study of patients undergoing EES from April to October 2016. Consecutive images of the same operative field at 10%, 30%, 50% and 100% light intensities were taken. Eight international experts were asked to each evaluate 100 anonymised, randomised images. District General Hospital. Twenty patients. Images were evaluated on a 5-point Likert scale (1 = significantly worse than average; 5 = significantly better than average) for detail of anatomy; colour contrast; overall quality; and suitability for operating. Mean scores for photographs at 10%, 30%, 50% and 100% light intensity were 3.22 (SD 0.93), 3.15 (SD 0.84), 3.08 (SD 0.88) and 3.10 (SD 0.86), respectively. In ANOVA models for the scores on each of the scales (anatomy, colour contrast, overall quality and suitability for operating), the effects of rater and patient were highly significant (P < .0005) but light intensity was non-significant (P = .34, .32, .21, .15, respectively). Images taken during surgery by our endoscope and operative camera have no loss of quality when taken at lower light intensities. We recommend the surgeon considers use of lower light intensities in endoscopic ear surgery. © 2018 John Wiley & Sons Ltd.

  12. Bringing quality improvement into the intensive care unit.

    PubMed

    McMillan, Tracy R; Hyzy, Robert C

    2007-02-01

    During the last several years, many governmental and nongovernmental organizations have championed the application of the principles of quality improvement to the practice of medicine, particularly in the area of critical care. To review the breadth of approaches to quality improvement in the intensive care unit, including measures such as mortality and length of stay, and the use of protocols, bundles, and the role of large, multiple-hospital collaboratives. Several agencies have participated in the application of the quality movement to medicine, culminating in the development of standards such as the intensive care unit core measures of the Joint Commission on Accreditation of Healthcare Organizations. Although "zero defects" may not be possible in all measurable variables of quality in the intensive care unit, several measures, such as catheter-related bloodstream infections, can be significantly reduced through the implementation of improved processes of care, such as care bundles. Large, multiple-center, quality improvement collaboratives, such as the Michigan Keystone Intensive Care Unit Project, may be particularly effective in improving the quality of care by creating a "bandwagon effect" within a geographic region. The quality revolution is having a significant effect in the critical care unit and is likely to be facilitated by the transition to the electronic medical record.

  13. Benefits of High-Intensity Intensive Care Unit Physician Staffing under the Affordable Care Act

    PubMed Central

    Logani, Sachin; Green, Adam; Gasperino, James

    2011-01-01

    The Affordable Care Act signed into law by President Obama, with its value-based purchasing program, is designed to link payment to quality processes and outcomes. Treatment of critically ill patients represents nearly 1% of the gross domestic product and 25% of a typical hospital budget. Data suggest that high-intensity staffing patterns in the intensive care unit (ICU) are associated with cost savings and improved outcomes. We evaluate the literature investigating the cost-effectiveness and clinical outcomes of high-intensity ICU physician staffing as recommended by The Leapfrog Group (a consortium of companies that purchase health care for their employees) and identify ways to overcome barriers to nationwide implementation of these standards. Hospitals that have implemented the Leapfrog initiative have demonstrated reductions in mortality and length of stay and increased cost savings. High-intensity staffing models appear to be an immediate cost-effective way for hospitals to meet the challenges of health care reform. PMID:22110908

  14. Quality of life in long-term survivors of intensive care.

    PubMed

    Buckley, T A; Cheng, A Y; Gomersall, C D

    2001-05-01

    Traditionally, outcome from intensive care has focused on mortality. The cost of intensive care and the limited resources devoted to patients who have a poor prognosis also raises questions about the utilisation of such resources. There is increasing pressure for outcome evaluation of intensive care to incorporate assessment of long-term survival and the quality of life in survivors. The principal objectives of this article were to examine current methods of assessing quality of life measures in critically ill patients surviving intensive care and to determine the quality of life of these survivors. Direct and computerised search of published research articles. Measurement of quality of life after intensive care is not common practice. There is a lack of consensus concerning appropriate measuring instruments to be used and how best to interpret results. Despite the availability of general outcome tools and disease specific instruments, there is a paucity of studies in the literature which include assessments of quality of life following intensive care unit (ICU) care. Generic health indices suggest that the quality of life in ICU survivors is acceptable though in certain sub-groups, e.g. adult respiratory distress syndrome and sepsis, quality of life may be moderately impaired. ICU survivors appear to suffer less disability than chronic physical disease patients. Assessment of outcome after intensive care should include health related quality of life measurements. A unifying framework is required to enhance communication between clinicians, administrators and investigators of quality of life research and also to enable more rational and effective decision making at the bedside. Patients who survive intensive care appear to enjoy a reasonable standard of quality of life. While their health status may not be as good, subjectively patients find this acceptable.

  15. Effects of high-intensity interval training on fatigue and quality of life in testicular cancer survivors.

    PubMed

    Adams, Scott C; DeLorey, Darren S; Davenport, Margie H; Fairey, Adrian S; North, Scott; Courneya, Kerry S

    2018-05-08

    Testicular cancer survivors (TCS) are at increased risk of cancer-related fatigue (CRF), psychosocial impairment, and poor mental health-related quality of life (HRQoL). Here, we examine the effects of high-intensity interval training (HIIT) on patient-reported outcomes (PROs) in TCS. Secondarily, we explore cardiorespiratory fitness as a mediator of intervention effects and select baseline characteristics as moderators of intervention effects. TCS (n = 63) were randomly assigned to 12 weeks of supervised HIIT or usual care (UC). PROs included CRF, depression, anxiety, stress, self-esteem, sleep quality, and HRQoL assessed at baseline, post-intervention, and 3-month follow-up. TCS (median 7 years postdiagnosis) completed 99% of training sessions and achieved 98% of target training intensity. ANCOVA revealed that, compared to UC, HIIT significantly improved post-intervention CRF (p = 0.003), self-esteem (p = 0.029), and multiple HRQoL domains (ps ≤ 0.05). Effects on CRF (p = 0.031) and vitality (p = 0.015) persisted at 3-month follow-up. Cardiorespiratory fitness changes mediated CRF and HRQoL improvements. CRF effects were larger for TCS with an inactive lifestyle, lower fitness, higher testosterone, and clinical fatigue at baseline. HIIT significantly improves CRF and HRQoL in TCS. Mediation by cardiorespiratory fitness and moderation by clinical characteristics suggests opportunities for targeted exercise interventions to optimise PROs in TCS.

  16. The role of precipitation type, intensity, and spatial distribution in source water quality after wildfire

    NASA Astrophysics Data System (ADS)

    Murphy, Sheila F.; Writer, Jeffrey H.; Blaine McCleskey, R.; Martin, Deborah A.

    2015-08-01

    Storms following wildfires are known to impair drinking water supplies in the southwestern United States, yet our understanding of the role of precipitation in post-wildfire water quality is far from complete. We quantitatively assessed water-quality impacts of different hydrologic events in the Colorado Front Range and found that for a three-year period, substantial hydrologic and geochemical responses downstream of a burned area were primarily driven by convective storms with a 30 min rainfall intensity >10 mm h-1. These storms, which typically occur several times each year in July-September, are often small in area, short-lived, and highly variable in intensity and geographic distribution. Thus, a rain gage network with high temporal resolution and spatial density, together with high-resolution stream sampling, are required to adequately characterize post-wildfire responses. We measured total suspended sediment, dissolved organic carbon (DOC), nitrate, and manganese concentrations that were 10-156 times higher downstream of a burned area compared to upstream during relatively common (50% annual exceedance probability) rainstorms, and water quality was sufficiently impaired to pose water-treatment concerns. Short-term water-quality impairment was driven primarily by increased surface runoff during higher intensity convective storms that caused erosion in the burned area and transport of sediment and chemical constituents to streams. Annual sediment yields downstream of the burned area were controlled by storm events and subsequent remobilization, whereas DOC yields were closely linked to annual runoff and thus were more dependent on interannual variation in spring runoff. Nitrate yields were highest in the third year post-wildfire. Results from this study quantitatively demonstrate that water quality can be altered for several years after wildfire. Because the southwestern US is prone to wildfires and high-intensity rain storms, the role of storms in post

  17. The role of precipitation type, intensity, and spatial distribution in source water quality after wildfire

    USGS Publications Warehouse

    Murphy, Sheila F.; Writer, Jeffrey H.; McCleskey, R. Blaine; Martin, Deborah A.

    2015-01-01

    Storms following wildfires are known to impair drinking water supplies in the southwestern United States, yet our understanding of the role of precipitation in post-wildfire water quality is far from complete. We quantitatively assessed water-quality impacts of different hydrologic events in the Colorado Front Range and found that for a three-year period, substantial hydrologic and geochemical responses downstream of a burned area were primarily driven by convective storms with a 30 min rainfall intensity >10 mm h−1. These storms, which typically occur several times each year in July–September, are often small in area, short-lived, and highly variable in intensity and geographic distribution. Thus, a rain gage network with high temporal resolution and spatial density, together with high-resolution stream sampling, are required to adequately characterize post-wildfire responses. We measured total suspended sediment, dissolved organic carbon (DOC), nitrate, and manganese concentrations that were 10–156 times higher downstream of a burned area compared to upstream during relatively common (50% annual exceedance probability) rainstorms, and water quality was sufficiently impaired to pose water-treatment concerns. Short-term water-quality impairment was driven primarily by increased surface runoff during higher intensity convective storms that caused erosion in the burned area and transport of sediment and chemical constituents to streams. Annual sediment yields downstream of the burned area were controlled by storm events and subsequent remobilization, whereas DOC yields were closely linked to annual runoff and thus were more dependent on interannual variation in spring runoff. Nitrate yields were highest in the third year post-wildfire. Results from this study quantitatively demonstrate that water quality can be altered for several years after wildfire. Because the southwestern US is prone to wildfires and high-intensity rain storms, the role of storms in post

  18. A pilot study examining the effects of low-volume high-intensity interval training and continuous low to moderate intensity training on quality of life, functional capacity and cardiovascular risk factors in cancer survivors.

    PubMed

    Toohey, Kellie; Pumpa, Kate L; Arnolda, Leonard; Cooke, Julie; Yip, Desmond; Craft, Paul S; Semple, Stuart

    2016-01-01

    The aim of this study was to evaluate the effects of low-volume high-intensity interval training and continuous low to moderate intensity training on quality of life, functional capacity and cardiovascular disease risk factors in cancer survivors. Cancer survivors within 24 months post-diagnosis were randomly assigned into the low-volume high-intensity interval training group ( n  = 8) or the continuous low to moderate intensity training group ( n  = 8) group for 36 sessions (12 weeks) of supervised exercise. The low-volume high-intensity interval training (LVHIIT) group performed 7 × 30 s intervals (≥85% maximal heart rate) and the continuous low to moderate intensity training (CLMIT) group performed continuous aerobic training for 20 min (≤55% maximal heart rate) on a stationary bike or treadmill. Significant improvements (time) were observed for 13 of the 23 dependent variables (ES 0.05-0.61, p  ≤ 0.05). An interaction effect was observed for six minute walk test (18.53% [32.43-4.63] ES 0.50, p  ≤ 0.01) with the LVHIIT group demonstrating greater improvements. These preliminary findings suggest that both interventions can induce improvements in quality of life, functional capacity and selected cardiovascular disease risk factors. The LVHIIT program was well tolerated by the participants and our results suggest that LVHIIT is the preferred modality to improve fitness (6MWT); it remains to be seen which intervention elicits the most clinically relevant outcomes for patients. A larger sample size with a control group is required to confirm the significance of these findings.

  19. A pilot study examining the effects of low-volume high-intensity interval training and continuous low to moderate intensity training on quality of life, functional capacity and cardiovascular risk factors in cancer survivors

    PubMed Central

    Pumpa, Kate L.; Arnolda, Leonard; Cooke, Julie; Yip, Desmond; Craft, Paul S.; Semple, Stuart

    2016-01-01

    Purpose The aim of this study was to evaluate the effects of low-volume high-intensity interval training and continuous low to moderate intensity training on quality of life, functional capacity and cardiovascular disease risk factors in cancer survivors. Methods Cancer survivors within 24 months post-diagnosis were randomly assigned into the low-volume high-intensity interval training group (n = 8) or the continuous low to moderate intensity training group (n = 8) group for 36 sessions (12 weeks) of supervised exercise. The low-volume high-intensity interval training (LVHIIT) group performed 7 × 30 s intervals (≥85% maximal heart rate) and the continuous low to moderate intensity training (CLMIT) group performed continuous aerobic training for 20 min (≤55% maximal heart rate) on a stationary bike or treadmill. Results Significant improvements (time) were observed for 13 of the 23 dependent variables (ES 0.05–0.61, p ≤ 0.05). An interaction effect was observed for six minute walk test (18.53% [32.43–4.63] ES 0.50, p ≤ 0.01) with the LVHIIT group demonstrating greater improvements. Conclusion These preliminary findings suggest that both interventions can induce improvements in quality of life, functional capacity and selected cardiovascular disease risk factors. The LVHIIT program was well tolerated by the participants and our results suggest that LVHIIT is the preferred modality to improve fitness (6MWT); it remains to be seen which intervention elicits the most clinically relevant outcomes for patients. A larger sample size with a control group is required to confirm the significance of these findings. PMID:27781180

  20. Effects of competition on great and blue tit reproduction: intensity and importance in relation to habitat quality.

    PubMed

    Dhondt, André A

    2010-01-01

    1. In studies on the effect of competition in plant communities two terms are used to describe its effects: the absolute reduction in growth of an individual as a consequence of the presence of another one is called intensity, while the relative impact of competition on an individual as a proportion of the impact of the whole environment is called importance. One school of thought is that the role of competition remains constant across productivity gradients, while the other is that it decreases with increasing severity. J.B. Grace (1991. A clarification of the debate between grime and tilman. Functional Ecology, 5, 583-587.) suggested that the apparent contradiction might be solved if we acknowledge that the two schools are discussing different aspects of competition: the intensity of competition might remain constant while its importance declines with increasing severity. 2. There are no studies that compare intensity and importance of competition in bird populations between areas that differ in quality or productivity and hence it is not possible to make predictions how intensity or importance of competition would vary between them. 3. I compared variation in intensity and importance of competition of three demographic variables between five plots that differ strongly in quality for great Parus major L. and blue tit Cyanistes caeruleus (L.). 4. Both intensity and importance of competition are larger in great than in blue tit populations meaning that the effect of competition on demographic variables is stronger in great than in blue tits and that the contribution of competition to variation in these variables is relatively higher in great than in blue tits. 5. Intensity of competition is higher in low quality than in high quality plots for both species, a result not expected from studies in plant communities. 6. Importance of competition varies strongly between plots. It is larger in oak-dominated plots than in mixed deciduous plots. 7. In birds breeding density

  1. High-intensity interval training combined with resistance training improves physiological capacities, strength and quality of life in multiple sclerosis patients: a pilot study.

    PubMed

    Zaenker, Pierre; Favret, Fabrice; Lonsdorfer, Evelyne; Muff, Guillaume; de Seze, Jérôme; Isner-Horobeti, Marie-Eve

    2018-02-01

    Numerous studies have shown that mild-to-moderate intensity or resistance exercise training improves physical capacities such as, peak oxygen consumption, maximal tolerated power and strength in multiple sclerosis patients. However, few studies have evaluated the effects of high-intensity interval training (HIIT) associated to with resistance training. Only few studies have analyzed difference between men and women before and after combined training. Moreover, the evaluation of exercise between ambulatory multiple sclerosis patients without disability (Expanded Disability Status Score [EDSS] 0-3) and patients with disabilities (EDSS 3.5-5) was not largely published. The main objective of our study was to determine if HIIT combined with resistance training improved aerobic and strength capacities as well as quality of life in multiple sclerosis patients and if gender and disabilities play a role in these changes. This study was an open-label uncontrolled study. The study was performed outside from conventional care facilities and including homebased training. Twenty-six multiple sclerosis patients have completed the program (19 women, 7 men; mean age 44.6±7.9 years, EDSS 2 [0-5]). We conducted a 12-week program of high-intensity interval training combined with resistance training at body weight. Peak oxygen consumption, maximal tolerated power, lactates, isokinetic strength of quadriceps and hamstrings (at 90°/s, 180°/s, and 240°/s) and quality of life were evaluated before and after the program. Peak oxygen consumption and maximum tolerated power improved by 13.5% and 9.4%, respectively. Isokinetic muscle strength increased in both quadriceps and hamstrings at each speed, with a rebalancing of strength between the two legs in quadriceps. Quality of life was also enhanced in three domains. Women showed better improvements than men in V̇O2peak, maximal tolerated power, lactates at the end of test, and heart rate peak, strength in both quadriceps and hamstrings

  2. Fluorescent and high intensity discharge lamp use in chambers and greenhouses

    NASA Technical Reports Server (NTRS)

    Langhans, Robert W.

    1994-01-01

    Fluorescent and High Intensity Discharge lamps have opened up great opportunities for researchers to study plant growth under controlled environment conditions and for commercial growers to increase plant production during low/light periods. Specific technical qualities of fluorescent and HID lamps have been critically reviewed. I will direct my remarks to fluorescent and high intensity discharge (HID) lamps in growth chambers, growth rooms, and greenhouses. I will discuss the advantages and disadvantages of using each lamp in growth chambers, growth rooms and greenhouses.

  3. Cancer and Exercise: Warburg Hypothesis, Tumour Metabolism and High-Intensity Anaerobic Exercise.

    PubMed

    Hofmann, Peter

    2018-01-31

    There is ample evidence that regular moderate to vigorous aerobic physical activity is related to a reduced risk for various forms of cancer to suggest a causal relationship. Exercise is associated with positive changes in fitness, body composition, and physical functioning as well as in patient-reported outcomes such as fatigue, sleep quality, or health-related quality of life. Emerging evidence indicates that exercise may also be directly linked to the control of tumour biology through direct effects on tumour-intrinsic factors. Beside a multitude of effects of exercise on the human body, one underscored effect of exercise training is to target the specific metabolism of tumour cells, namely the Warburg-type highly glycolytic metabolism. Tumour metabolism as well as the tumour⁻host interaction may be selectively influenced by single bouts as well as regularly applied exercise, dependent on exercise intensity, duration, frequency and mode. High-intensity anaerobic exercise was shown to inhibit glycolysis and some studies in animals showed that effects on tumour growth might be stronger compared with moderate-intensity aerobic exercise. High-intensity exercise was shown to be safe in patients; however, it has to be applied carefully with an individualized prescription of exercise.

  4. MO-AB-210-00: Diagnostic Ultrasound Imaging Quality Control and High Intensity Focused Ultrasound Therapy Hands-On Workshop

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrationsmore » with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant

  5. Biopotentiality of High Efficient Aerobic Denitrifier Bacillus megaterium S379 for Intensive Aquaculture Water Quality Management.

    PubMed

    Gao, Junqian; Gao, Dan; Liu, Hao; Cai, Jiajai; Zhang, Junqi; Qi, Zhengliang

    2018-05-24

    Excessive nitrite accumulation is a very tough issue for intensive aquaculture. A high efficient aerobic denitrifier Bacillus megaterium S379 with 91.71±0.17% of NO 2 - -N (65 mg L -1 ) removal was successfully isolated for solving the problem. Denitrification of S379 showed excellent environment adaptation that it kept high nitrite removal ratio (more than 85%) when temperature ranged from 25°C to 40°C and pH varied between 7.0 and 9.0, and could endure as high as 560 mg L -1 of NO 2 - -N. Immobilization of S379 could enhance denitrification even when NO 2 - -N adding amount got to 340 mg L -1 . Immobilized cells also showed well pollutants removal performance in aquaculture wastewater treatment. Moreover, S379 possessed positive hydrolase activities for starch, casein, cellulose and fat and bore more than 60 ppt of salinity. Totally, all the results revealed significant potentiality of immobilized S379 applied in aquaculture water quality management. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Effect of high-hydrostatic pressure and moderate-intensity pulsed electric field on plum.

    PubMed

    García-Parra, J; González-Cebrino, F; Delgado-Adámez, J; Cava, R; Martín-Belloso, O; Élez-Martínez, P; Ramírez, R

    2018-03-01

    Moderate intensity pulse electric fields were applied in plum with the aim to increase bioactive compounds content of the fruit, while high-hydrostatic pressure was applied to preserve the purées. High-hydrostatic pressure treatment was compared with an equivalent thermal treatment. The addition of ascorbic acid during purée manufacture was also evaluated. The main objective of this study was to assess the effects on microorganisms, polyphenoloxidase, color and bioactive compounds of high-hydrostatic pressure, or thermal-processed plum purées made of moderate intensity pulse electric field-treated or no-moderate intensity pulse electric field-treated plums, after processing during storage. The application of moderate intensity pulse electric field to plums slightly increased the levels of anthocyanins and the antioxidant activity of purées. The application of Hydrostatic-high pressure (HHP) increased the levels of bioactive compounds in purées, while the thermal treatment preserved better the color during storage. The addition of ascorbic acid during the manufacture of plum purée was an important factor for the final quality of purées. The color and the bioactive compounds content were better preserved in purées with ascorbic acid. The no inactivation of polyphenoloxidase enzyme with treatments applied in this study affected the stability purées. Probably more intense treatments conditions (high-hydrostatic pressure and thermal treatment) would be necessary to reach better quality and shelf life during storage.

  7. The effectiveness of high-intensity versus low-intensity back schools in an occupational setting: a pragmatic randomized controlled trial.

    PubMed

    Heymans, Martijn W; de Vet, Henrica C W; Bongers, Paulien M; Knol, Dirk L; Koes, Bart W; van Mechelen, Willem

    2006-05-01

    Randomized controlled trial. To compare high- and low-intensity back schools with usual care in occupational health care. The content and intensity of back schools vary widely and the methodologic quality of randomized controlled trials is generally weak. Until now, no back school has proven to be superior for workers sick-listed because of subacute nonspecific low back pain. Workers (n = 299) sick-listed for a period of 3 to 6 weeks because of nonspecific low back pain were recruited by the occupational physician and randomly assigned to a high-intensity back school, a low-intensity back school, or care as usual. Outcome measures were days until return to work, total days of sick-leave, pain, functional status, kinesiophobia, and perceived recovery and were assessed at baseline and at 3 and 6 months of follow-up. Principal analyses were performed according to the intention-to-treat principle. We randomly allocated 299 workers. Workers in the low-intensity back school returned to work faster compared with usual care and the high-intensity back school, with hazard ratios of 1.4 (P = 0.06) and 1.3 (P = 0.09), respectively. The comparison between high-intensity back school and usual care resulted in a hazard ratio of 1.0 (P = 0.83). The median number of sick-leave days was 68, 75, and 85 in the low-intensity back school, usual care, and high-intensity back school, respectively. Beneficial effects on functional status and kinesiophobia were found at 3 months in favor of the low-intensity back school. No substantial differences on pain and perceived recovery were found between groups. The low-intensity back school was most effective in reducing work absence, functional disability, and kinesiophobia, and more workers in this group scored a higher perceived recovery during the 6-month follow-up.

  8. Improved clinical status, quality of life, and walking capacity in Parkinson's disease after body weight-supported high-intensity locomotor training.

    PubMed

    Rose, Martin H; Løkkegaard, Annemette; Sonne-Holm, Stig; Jensen, Bente R

    2013-04-01

    To evaluate the effect of body weight-supported progressive high-intensity locomotor training in Parkinson's disease (PD) on (1) clinical status; (2) quality of life; and (3) gait capacity. Open-label, fixed sequence crossover study. University motor control laboratory. Patients (N=13) with idiopathic PD (Hoehn and Yahr stage 2 or 3) and stable medication use. Patients completed an 8-week (3 × 1h/wk) training program on a lower-body positive-pressure treadmill. Body weight support was used to facilitate increased intensity and motor challenges during treadmill training. The training program contained combinations of (1) running and walking intervals, (2) the use of sudden changes (eg, in body weight support and speed), (3) different types of locomotion (eg, chassé, skipping, and jumps), and (4) sprints at 50 percent body weight. The Movement Disorders Society-Unified Parkinson's Disease Rating Scale (MDS-UPDRS), Parkinson's Disease Questionnaire-39 items (PDQ-39), and the six-minute walk test were conducted 8 weeks before and pre- and posttraining. At the end of training, statistically significant improvements were found in all outcome measures compared with the control period. Total MDS-UPDRS score changed from (mean ± 1SD) 58±18 to 47±18, MDS-UPDRS motor part score changed from 35±10 to 29±12, PDQ-39 summary index score changed from 22±13 to 13±12, and the six-minute walking distance changed from 576±93 to 637±90m. Body weight-supported progressive high-intensity locomotor training is feasible and well tolerated by patients with PD. The training improved clinical status, quality of life, and gait capacity significantly. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  9. Water Quantity and Water Quality Impacts of Intensive Woody Biomass Feedstock Production in the Southeastern US.

    NASA Astrophysics Data System (ADS)

    Bitew, M. M.; Jackson, C. R.; Vache, K. B.; Griffiths, N.; Starr, G.; McDonnell, J.; Rau, B.; Younger, S. E.; Fouts, K.

    2016-12-01

    Intensively managed loblolly pine is a candidate species for biofuel feedstock production in the southeastern Coastal Plain of the United States. However, the water quantity and quality effects of high intensity, short-rotation silviculture are largely unknown. Here we evaluate the potential hydrologic and water quality impacts of biofuel-induced land use changes based on model scenarios developed using existing forest BMPs and industry wide experiences. We quantified the effect of bio-energy production scenarios on each of water the balance components by applying an integrated physically based distributed watershed modeling system, and multi-objective assessment functions that accurately describes the flow regimes, water quality, and isotopic observations from three experimental headwater watersheds of Fourmile Creek at Savannah River Site, SC. The model incorporates optimized travel times of groundwater flowpaths and flow control processes in the riparian region allowing water quality analysis of groundwater dominated watershed systems. We compared five different short rotation pine management scenarios ranging from 35 year (low intensity) to 10 year (high intensity) rotations and a mixture of forestry and agriculture/pasture production practices. Simulation results, based on long-term climate records, revealed that complete conversion to short-rotation woody crops would have a negligible effect on water budget components; <2% decrease in streamflow, <1.5% increase in actual evapotranspiration, an average 0.5 m fall in the groundwater table, and no change in subsurface flow due to biofuel production. Simulation results of mixed 50% agriculture and pasture and 50% short-rotation woody crops showed the largest deviation in water budget components compared to the reference condition. Analysis of extreme stream flows showed that the largest effect was observed in the low intensity mixed land use scenario. The smallest effect was in the low intensity biomass

  10. Voluntary peer review as innovative tool for quality improvement in the intensive care unit--a retrospective descriptive cohort study in German intensive care units.

    PubMed

    Kumpf, Oliver; Bloos, Frank; Bause, Hanswerner; Brinkmann, Alexander; Deja, Maria; Marx, Gernot; Kaltwasser, Arnold; Dubb, Rolf; Muhl, Elke; Greim, Clemens-A; Weiler, Norbert; Chop, Ines; Jonitz, Günther; Schaefer, Henning; Felsenstein, Matthias; Liebeskind, Ursula; Leffmann, Carsten; Jungbluth, Annemarie; Waydhas, Christian; Pronovost, Peter; Spies, Claudia; Braun, Jan-Peter

    2014-01-01

    Quality improvement and safety in intensive care are rapidly evolving topics. However, there is no gold standard for assessing quality improvement in intensive care medicine yet. In 2007 a pilot project in German intensive care units (ICUs) started using voluntary peer reviews as an innovative tool for quality assessment and improvement. We describe the method of voluntary peer review and assessed its feasibility by evaluating anonymized peer review reports and analysed the thematic clusters highlighted in these reports. Retrospective data analysis from 22 anonymous reports of peer reviews. All ICUs - representing over 300 patient beds - had undergone voluntary peer review. Data were retrieved from reports of peers of the review teams and representatives of visited ICUs. Data were analysed with regard to number of topics addressed and results of assessment questionnaires. Reports of strengths, weaknesses, opportunities and threats (SWOT reports) of these ICUs are presented. External assessment of structure, process and outcome indicators revealed high percentages of adherence to predefined quality goals. In the SWOT reports 11 main thematic clusters were identified representative for common ICUs. 58.1% of mentioned topics covered personnel issues, team and communication issues as well as organisation and treatment standards. The most mentioned weaknesses were observed in the issues documentation/reporting, hygiene and ethics. We identified several unique patterns regarding quality in the ICU of which long-term personnel problems und lack of good reporting methods were most interesting Conclusion: Voluntary peer review could be established as a feasible and valuable tool for quality improvement. Peer reports addressed common areas of interest in intensive care medicine in more detail compared to other methods like measurement of quality indicators.

  11. Measuring technical efficiency of output quality in intensive care units.

    PubMed

    Junoy, J P

    1997-01-01

    Presents some examples of the implications derived from imposing the objective of maximizing social welfare, subject to limited resources, on ethical care patients management in respect of quality performance of health services. Conventional knowledge of health economics points out that critically ill patients are responsible for increased use of technological resources and that they receive a high proportion of health care resources. Attempts to answer, from the point of view of microeconomics, the question: how do we measure comparative efficiency in the management of intensive care units? Analyses this question through data from an international empirical study using micro-economic measures of productive efficiency in public services (data envelopment analysis). Results show a 28.8 per cent level of technical inefficiency processing data from 25 intensive care units in the USA.

  12. Effect of intense short rainfall events on coastal water quality parameters from remote sensing data

    NASA Astrophysics Data System (ADS)

    Corbari, Chiara; Lassini, Fabio; Mancini, Marco

    2016-07-01

    Strong rainfall events, especially during summer, in small river basins cause spills in the sea that often compromise the quality of coastal waters. The goal of this paper is then to study the changes of coastal waters quality as a result of intense rainfall events during the bathing season through the use of remote sensing data. These analyses are performed at the outlets of small watersheds which are not usually affected by high sediment transport as in the case of large basins which are persistently affected by intense solid transport which does not allow retrieving a reliable correlation between rainfall events and water quality parameters. Four small watersheds in different Italian regions on the Mediterranean Sea are selected for this study. The remotely sensed parameters of turbidity, total suspend solids and secchi disk depth, are retrieved from MODIS data. Secchi disk depths are also compared to available ground data during the summer seasons between 2003 and 2006 showing good correlations. Then the spatial and temporal changes of these parameters are analyzed after intense short storm events. Increases of turbidity and total suspend solids are found to be around 35 NTU and 20 mg L-1 respectively depending on the intensity of the rainfall event and on the distance from the shoreline. Moreover the recovery of water quality after the rain event is reached after two or three days.

  13. [Assessment of farmland soil quality under different utilization intensity in arid area].

    PubMed

    Gui, Dong-Wei; Mu, Gui-Jin; Lei, Jia-Qiang; Zeng, Fan-Jiang; Wang, Hui

    2009-04-01

    Based on the 2005-2007 experimental data in Cele oasis in the southern margin of Tarim Basin of Xinjiang, the soil quality of four typical types of farmland with different utilization intensity, i.e., farmland with high input, farmland with normal input, newly reclaimed farmland, and farmland in oasis' interior, was analyzed and assessed by using sustainable yield index, soil improvement index, and soil quality synthesis index. Among the farmlands, there were significant differences in the contents of soil organic matter, available nitrogen, and available phosphorus. Newly reclaimed farmland had the lowest level of soil quality, while the farmland in oasis' interior had relatively higher soil quality. This study could help the reasonable exploitation and utilization of farmlands in Cele oasis, and the protection of local farmland eco-environment.

  14. Impact of High-Intensity-NIV on the heart in stable COPD: a randomised cross-over pilot study.

    PubMed

    Duiverman, Marieke Leontine; Maagh, Petra; Magnet, Friederike Sophie; Schmoor, Claudia; Arellano-Maric, Maria Paola; Meissner, Axel; Storre, Jan Hendrik; Wijkstra, Peter Jan; Windisch, Wolfram; Callegari, Jens

    2017-05-02

    Although high-intensity non-invasive ventilation has been shown to improve outcomes in stable COPD, it may adversely affect cardiac performance. Therefore, the aims of the present pilot study were to compare cardiac and pulmonary effects of 6 weeks of low-intensity non-invasive ventilation and 6 weeks of high-intensity non-invasive ventilation in stable COPD patients. In a randomised crossover pilot feasibility study, the change in cardiac output after 6 weeks of each NIV mode compared to baseline was assessed with echocardiography in 14 severe stable COPD patients. Furthermore, CO during NIV, gas exchange, lung function, and health-related quality of life were investigated. Three patients dropped out: two deteriorated on low-intensity non-invasive ventilation, and one presented with decompensated heart failure while on high-intensity non-invasive ventilation. Eleven patients were included in the analysis. In general, cardiac output and NTproBNP did not change, although individual effects were noticed, depending on the pressures applied and/or the co-existence of heart failure. High-intensity non-invasive ventilation tended to be more effective in improving gas exchange, but both modes improved lung function and the health-related quality of life. Long-term non-invasive ventilation with adequate pressure to improve gas exchange and health-related quality of life did not have an overall adverse effect on cardiac performance. Nevertheless, in patients with pre-existing heart failure, the application of very high inspiratory pressures might reduce cardiac output. The trial was registered in the Deutsches Register Klinischer Studien (DRKS-ID: DRKS00007977 ).

  15. Novel high-energy physics studies using intense lasers and plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leemans, Wim P.; Bulanov, Stepan; Esarey, Eric

    2015-06-29

    In the framework of the project “Novel high-energy physics studies using intense lasers and plasmas” we conducted the study of ion acceleration and “flying mirrors” with high intensity lasers in order to develop sources of ion beams and high frequency radiation for different applications. Since some schemes of laser ion acceleration are also considered a good source of “flying mirrors”, we proposed to investigate the mechanisms of “mirror” formation. As a result we were able to study the laser ion acceleration from thin foils and near critical density targets. We identified several fundamental factors limiting the acceleration in the RPAmore » regime and proposed the target design to compensate these limitations. In the case of near critical density targets, we developed a concept for the laser driven ion source for the hadron therapy. Also we studied the mechanism of “flying mirror” generation during the intense laser interaction with thin solid density targets. As for the laser-based positron creation and capture we initially proposed to study different regimes of positron beam generation and positron beam cooling. Since the for some of these schemes a good quality electron beam is required, we studied the generation of ultra-low emittance electron beams. In order to understand the fundamental physics of high energy electron beam interaction with high intensity laser pulses, which may affect the efficient generation of positron beams, we studied the radiation reaction effects.« less

  16. High-intensity focused ultrasound (HIFU) for pancreatic carcinoma: evaluation of feasibility, reduction of tumour volume and pain intensity.

    PubMed

    Marinova, Milka; Rauch, Maximilian; Mücke, Martin; Rolke, Roman; Gonzalez-Carmona, Maria A; Henseler, Jana; Cuhls, Henning; Radbruch, Lukas; Strassburg, Christian P; Zhang, Lian; Schild, Hans H; Strunk, Holger M

    2016-11-01

    Prognosis of patients with locally advanced pancreatic adenocarcinoma is extremely poor. They often suffer from cancer-related pain reducing their quality of life. This prospective observational study aimed to evaluate feasibility, local tumour response, and changes in quality of life and symptoms in Caucasian patients with locally advanced pancreatic cancer treated by ultrasound-guided high-intensity focused ultrasound (HIFU). Thirteen patients underwent HIFU, five with stage III, eight with stage IV UICC disease. Ten patients received simultaneous palliative chemotherapy. Postinterventional clinical assessment included evaluation of quality of life and symptom changes using standardized questionnaires. CT and MRI follow-up evaluated the local tumour response. HIFU was successfully performed in all patients. Average tumour reduction was 34.2 % at 6 weeks and 63.9 % at 3 months. Complete or partial relief of cancer-related pain was achieved in 10 patients (77 %), five of whom required less analgesics for pain control. Quality of life was improved revealing increased global health status and alleviated symptoms. HIFU treatment was well tolerated. Eight patients experienced transient abdominal pain directly after HIFU. HIFU ablation of pancreatic carcinoma is a feasible, safe and effective treatment with a crucial benefit in terms of reduction of tumour volume and pain intensity. • US-guided HIFU is feasible and safe for patients with unresectable pancreatic cancer. • HIFU can considerably reduce tumour volume and cancer-related pain. • Patients treated with HIFU experienced significant and lasting reduction of pain intensity. • HIFU has a crucial clinical benefit for patients with pancreatic cancer.

  17. Sleep quality and high intensity interval training at two different times of day: A crossover study on the influence of the chronotype in male collegiate soccer players.

    PubMed

    Vitale, Jacopo A; Bonato, Matteo; Galasso, Letizia; La Torre, Antonio; Merati, Giampiero; Montaruli, Angela; Roveda, Eliana; Carandente, Franca

    2017-01-01

    The influence of the chronotype on the sleep quality in male collegiate soccer players in response to acute high intensity interval training (HIIT) performed at two different times of day was evaluated. The sleep quality was poorer in the morning-type than in the evening-type players after the evening HIIT session, whereas no significant changes in the sleep quality of the two chronotypes after the morning HIIT session was observed. The results suggest that an athlete's chronotype should be taken into account when scheduling training sessions and to promote faster recovery processes.

  18. Voluntary peer review as innovative tool for quality improvement in the intensive care unit – a retrospective descriptive cohort study in German intensive care units

    PubMed Central

    Kumpf, Oliver; Bloos, Frank; Bause, Hanswerner; Brinkmann, Alexander; Deja, Maria; Marx, Gernot; Kaltwasser, Arnold; Dubb, Rolf; Muhl, Elke; Greim, Clemens-A.; Weiler, Norbert; Chop, Ines; Jonitz, Günther; Schaefer, Henning; Felsenstein, Matthias; Liebeskind, Ursula; Leffmann, Carsten; Jungbluth, Annemarie; Waydhas, Christian; Pronovost, Peter; Spies, Claudia; Braun, Jan-Peter

    2014-01-01

    Introduction: Quality improvement and safety in intensive care are rapidly evolving topics. However, there is no gold standard for assessing quality improvement in intensive care medicine yet. In 2007 a pilot project in German intensive care units (ICUs) started using voluntary peer reviews as an innovative tool for quality assessment and improvement. We describe the method of voluntary peer review and assessed its feasibility by evaluating anonymized peer review reports and analysed the thematic clusters highlighted in these reports. Methods: Retrospective data analysis from 22 anonymous reports of peer reviews. All ICUs – representing over 300 patient beds – had undergone voluntary peer review. Data were retrieved from reports of peers of the review teams and representatives of visited ICUs. Data were analysed with regard to number of topics addressed and results of assessment questionnaires. Reports of strengths, weaknesses, opportunities and threats (SWOT reports) of these ICUs are presented. Results: External assessment of structure, process and outcome indicators revealed high percentages of adherence to predefined quality goals. In the SWOT reports 11 main thematic clusters were identified representative for common ICUs. 58.1% of mentioned topics covered personnel issues, team and communication issues as well as organisation and treatment standards. The most mentioned weaknesses were observed in the issues documentation/reporting, hygiene and ethics. We identified several unique patterns regarding quality in the ICU of which long-term personnel problems und lack of good reporting methods were most interesting Conclusion: Voluntary peer review could be established as a feasible and valuable tool for quality improvement. Peer reports addressed common areas of interest in intensive care medicine in more detail compared to other methods like measurement of quality indicators. PMID:25587245

  19. Sleep quality and covariates as predictors of pain intensity among the general population in rural China.

    PubMed

    Liu, Xiao-Kun; Xiao, Shui-Yuan; Zhou, Liang; Hu, Mi; Zhou, Wei; Liu, Hui-Ming

    2018-01-01

    The aims of this study were to investigate the distribution of sleep quality and its relationship with the prevalence of pain among rural Chinese people and to explore the association between sleep quality and pain intensity among the general population in real-life settings. This cross-sectional survey included a total of 2052 adults from rural areas in Liuyang, Hunan Province, recruited through random multistage sampling. The distributions of sleep quality and pain prevalence among the participants over a 4-week period were described. Because of multicollinearity among variables, the influence of self-rated sleep quality and psychosocial covariates on pain intensity was explored using a ridge regression model. The data showed that participants reporting all categories of sleep quality experienced some degree of pain. Sleep quality, along with physical and mental health, was a negative predictor of pain intensity among the general population. Symptoms of depression positively predicted pain intensity. Poor sleep quality increased pain intensity among the participants. Both previous research and the present data suggest that improving sleep quality may significantly decrease pain intensity in the general population. The relationship between sleep and pain may be bidirectional. This finding also suggests that treatment for sleep disorders and insomnia should be addressed in future efforts to alleviate pain intensity.

  20. The Impact of Intense Exercise on Semen Quality

    PubMed Central

    Jóźków, Paweł; Rossato, Marco

    2016-01-01

    With expanding knowledge on the health benefits of exercise, there is an increasing demand for information on the andrological consequences of participating in sports. These consequences are especially important in the context of infertility problems worldwide. The so-called “male factor” is reported in up to 50% of couples having trouble with conception. The answer to the question, “Is physical activity good for male reproductive health?” is not straightforward. A number of studies have suggested that significant changes in semen parameters may occur due to sports training of certain types, intensities, and durations. The changes to these parameters vary in scope, direction, and magnitude. Findings in recreational athletes have also differed from those in professional athletes. This review of the current literature suggests that intense physical activity may affect the semen concentration, as well as the number of motile and morphologically normal spermatozoa. Training at higher intensities and with increased loads seems to be associated with more profound changes in semen quality. In recreational athletes, exercise has either a positive or neutral effect on semen parameters. Due to many limitations (e.g., global sperm count trends, concerns about the quality control of sperm evaluations, and new standards for semen analysis), comparisons among historical data and their interpretation are difficult. PMID:27645515

  1. LED Lighting - Modification of Growth, Metabolism, Yield and Flour Composition in Wheat by Spectral Quality and Intensity.

    PubMed

    Monostori, István; Heilmann, Márk; Kocsy, Gábor; Rakszegi, Marianna; Ahres, Mohamed; Altenbach, Susan B; Szalai, Gabriella; Pál, Magda; Toldi, Dávid; Simon-Sarkadi, Livia; Harnos, Noémi; Galiba, Gábor; Darko, Éva

    2018-01-01

    The use of light-emitting diode (LED) technology for plant cultivation under controlled environmental conditions can result in significant reductions in energy consumption. However, there is still a lack of detailed information on the lighting conditions required for optimal growth of different plant species and the effects of light intensity and spectral composition on plant metabolism and nutritional quality. In the present study, wheat plants were grown under six regimens designed to compare the effects of LED and conventional fluorescent lights on growth and development, leaf photosynthesis, thiol and amino acid metabolism as well as grain yield and flour quality of wheat. Benefits of LED light sources over fluorescent lighting were manifested in both yield and quality of wheat. Elevated light intensities made possible with LEDs increased photosynthetic activity, the number of tillers, biomass and yield. At lower light intensities, blue, green and far-red light operated antagonistically during the stem elongation period. High photosynthetic activity was achieved when at least 50% of red light was applied during cultivation. A high proportion of blue light prolonged the juvenile phase, while the shortest flowering time was achieved when the blue to red ratio was around one. Blue and far-red light affected the glutathione- and proline-dependent redox environment in leaves. LEDs, especially in Blue, Pink and Red Low Light (RedLL) regimens improved flour quality by modifying starch and protein content, dough strength and extensibility as demonstrated by the ratios of high to low molecular weight glutenins, ratios of glutenins to gliadins and gluten spread values. These results clearly show that LEDs are efficient for experimental wheat cultivation, and make it possible to optimize the growth conditions and to manipulate metabolism, yield and quality through modification of light quality and quantity.

  2. Organizational Factors Associated With Perceived Quality of Patient Care in Closed Intensive Care Units.

    PubMed

    McIntosh, Nathalie; Oppel, Eva; Mohr, David; Meterko, Mark

    2017-09-01

    Improving patient care quality in intensive care units is increasingly important as intensive care unit services account for a growing proportion of hospital services. Organizational factors associated with quality of patient care in such units have been identified; however, most were examined in isolation, making it difficult to assess the relative importance of each. Furthermore, though most intensive care units now use a closed model, little research has been done in this specific context. To examine the relative importance of organizational factors associated with patient care quality in closed intensive care units. In a national exploratory, cross-sectional study focused on intensive care units at US Veterans Health Administration acute care hospitals, unit directors were surveyed about nurse and physician staffing, work resources and training, patient care coordination, rounding, and perceptions of patient care quality. Administrative records yielded data on patient volume and facility teaching status. Descriptive statistics, bivariate analyses, and regression modeling were used for data analysis. Sixty-nine completed surveys from directors of closed intensive care units were returned. Regression model results showed that better patient care coordination (β = 0.43; P = .01) and having adequate work resources (β = 0.26; P = .02) were significantly associated with higher levels of patient care quality in such units ( R 2 = 0.22). Augmenting work resources and/or focusing limited hospital resources on improving patient care coordination may be the most productive ways to improve patient care quality in closed intensive care units. ©2017 American Association of Critical-Care Nurses.

  3. High-intensity resistance training in multiple sclerosis - An exploratory study of effects on immune markers in blood and cerebrospinal fluid, and on mood, fatigue, health-related quality of life, muscle strength, walking and cognition.

    PubMed

    Kierkegaard, Marie; Lundberg, Ingrid E; Olsson, Tomas; Johansson, Sverker; Ygberg, Sofia; Opava, Christina; Holmqvist, Lotta Widén; Piehl, Fredrik

    2016-03-15

    High-intensity resistance training is unexplored in people with multiple sclerosis. To evaluate effects of high-intensity resistance training on immune markers and on measures of mood, fatigue, health-related quality of life, muscle strength, walking and cognition. Further, to describe participants' opinion and perceived changes of the training. Twenty patients with relapsing-remitting multiple sclerosis performed high-intensity resistance training at an intensity of 80% of one-repetition maximum, twice a week for 12 weeks. Blood and optional cerebrospinal fluid samples, and data on secondary outcome measures were collected before and after intervention. A study-specific questionnaire was used for capturing participants' opinion. Seventeen participants completed the study. Plasma cytokine levels of tumor necrosis factor were significantly decreased post-intervention (p=0.001). Exploratory cytokine analyses in cerebrospinal fluid (n=8) did not reveal major changes. Significant and clinically important improvements were found in fatigue (p=0.001) and health-related quality of life (p=0.004). Measures of mood (p=0.002), muscle strength (p ≤ 0.001), walking speed (p=0.013) and cognition (p=0.04) were also improved. A majority of participants evaluated the training as very good and perceived changes to the better. High-intensity resistance training in persons with relapsing remitting multiple sclerosis with low disability had positive effects on peripheral pro-inflammatory cytokine levels, led to clinically relevant improvements in measures of fatigue and health-related quality of life, and was well tolerated. These results provide a basis for a larger randomized trial. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Correlation of neonatal intensive care unit performance across multiple measures of quality of care.

    PubMed

    Profit, Jochen; Zupancic, John A F; Gould, Jeffrey B; Pietz, Kenneth; Kowalkowski, Marc A; Draper, David; Hysong, Sylvia J; Petersen, Laura A

    2013-01-01

    To examine whether high performance on one measure of quality is associated with high performance on others and to develop a data-driven explanatory model of neonatal intensive care unit (NICU) performance. We conducted a cross-sectional data analysis of a statewide perinatal care database. Risk-adjusted NICU ranks were computed for each of 8 measures of quality selected based on expert input. Correlations across measures were tested using the Pearson correlation coefficient. Exploratory factor analysis was used to determine whether underlying factors were driving the correlations. Twenty-two regional NICUs in California. In total, 5445 very low-birth-weight infants cared for between January 1, 2004, and December 31, 2007. Pneumothorax, growth velocity, health care-associated infection, antenatal corticosteroid use, hypothermia during the first hour of life, chronic lung disease, mortality in the NICU, and discharge on any human breast milk. The NICUs varied substantially in their clinical performance across measures of quality. Of 28 unit-level correlations, 6 were significant (ρ < .05). Correlations between pairs of measures of quality of care were strong (ρ ≥ .5) for 1 pair, moderate (range, ρ ≥ .3 to ρ < .5) for 8 pairs, weak (range, ρ ≥ .1 to ρ < .3) for 5 pairs, and negligible (ρ < .1) for 14 pairs. Exploratory factor analysis revealed 4 underlying factors of quality in this sample. Pneumothorax, mortality in the NICU, and antenatal corticosteroid use loaded on factor 1; growth velocity and health care-associated infection loaded on factor 2; chronic lung disease loaded on factor 3; and discharge on any human breast milk loaded on factor 4. In this sample, the ability of individual measures of quality to explain overall quality of neonatal intensive care was modest.

  5. Correlation of Neonatal Intensive Care Unit Performance Across Multiple Measures of Quality of Care

    PubMed Central

    Profit, J; Zupancic, JAF; Gould, JB; Pietz, K; Kowalkowski, MA; Draper, D; Hysong, SJ; Petersen, LA

    2014-01-01

    Objectives To examine whether high performance on one measure of quality is associated with high performance on others and to develop a data-driven explanatory model of neonatal intensive care unit (NICU) performance. Design We conducted a cross-sectional data analysis of a statewide perinatal care database. Risk-adjusted NICU ranks were computed for each of 8 measures of quality selected based on expert input. Correlations across measures were tested using the Pearson correlation coefficient. Exploratory factor analysis was used to determine whether underlying factors were driving the correlations. Setting Twenty-two regional NICUs in California. Patients In total, 5445 very low-birth-weight infants cared for between January 1, 2004, and December 31, 2007. Main Outcomes Measures Pneumothorax, growth velocity, health care–associated infection, antenatal corticosteroid use, hypothermia during the first hour of life, chronic lung disease, mortality in the NICU, and discharge on any human breast milk. Results The NICUs varied substantially in their clinical performance across measures of quality. Of 28 unit-level correlations only 6 were significant (P < .05). Correlations between pairs of quality measures were strong (ρ > .5) for 1 pair, moderate (.3 < |ρ| < .5) for 8 pairs, weak (.1 < |ρ| < .3) for 5 pairs and negligible (|ρ| < .1) for 14 pairs. Exploratory factor analysis revealed 4 underlying factors of quality in this sample. Pneumothorax, mortality in the NICU, and antenatal corticosteroid use loaded on factor 1; growth velocity and health care–associated infection loaded on factor 2; chronic lung disease loaded on factor 3; and discharge on any human breast milk loaded on factor 4. Conclusion In this sample, the ability of individual measures of quality to explain overall quality of neonatal intensive care was modest. PMID:23403539

  6. Quality and performance measures of strain on intensive care capacity: a protocol for a systematic review.

    PubMed

    Soltani, S Abolfazi; Ingolfsson, Armann; Zygun, David A; Stelfox, Henry T; Hartling, Lisa; Featherstone, Robin; Opgenorth, Dawn; Bagshaw, Sean M

    2015-11-12

    The matching of critical care service supply with demand is fundamental for the efficient delivery of advanced life support to patients in urgent need. Mismatch in this supply/demand relationship contributes to "intensive care unit (ICU) capacity strain," defined as a time-varying disruption in the ability of an ICU to provide well-timed and high-quality intensive care support to any and all patients who are or may become critically ill. ICU capacity strain leads to suboptimal quality of care and may directly contribute to heightened risk of adverse events, premature discharges, unplanned readmissions, and avoidable death. Unrelenting strain on ICU capacity contributes to inefficient health resource utilization and may negatively impact the satisfaction of patients, their families, and frontline providers. It is unknown how to optimally quantify the instantaneous and temporal "stress" an ICU experiences due to capacity strain. We will perform a systematic review to identify, appraise, and evaluate quality and performance measures of strain on ICU capacity and their association with relevant patient-centered, ICU-level, and health system-level outcomes. Electronic databases (i.e., MEDLINE, EMBASE, CINAHL, Cochrane Database of Systematic Reviews, Cochrane Central Register of Controlled Trials, Web of Science, and the Agency of Healthcare Research and Quality (AHRQ) - National Quality Measures Clearinghouse (NQMC)) will be searched for original studies of measures of ICU capacity strain. Selected gray literature sources will be searched. Search themes will focus on intensive care, quality, operations management, and capacity. Analysis will be primarily narrative. Each identified measure will be defined, characterized, and evaluated using the criteria proposed by the US Strategic Framework Board for a National Quality Measurement and Reporting System (i.e., importance, scientific acceptability, usability, feasibility). Our systematic review will comprehensively

  7. High-Power, High-Intensity Laser Propagation and Interactions

    DTIC Science & Technology

    2014-03-10

    wave Brillouin mixing [89,90]. transmitted beam is phase conjugated target initial wave front nn  1 turbulent air Figure 14. Using phase and...discussed in connection with both high-power and high-intensity lasers is propagation in a turbulent atmosphere . Laser propagation in atmospheric ... turbulence can results in beam centroid wander, spreading and intensity scintillation. A phase conjugation technique to mitigate the effects of atmospheric

  8. Effects of stress management program on the quality of nursing care and intensive care unit nurses

    PubMed Central

    Pahlavanzadeh, Saied; Asgari, Zohreh; Alimohammadi, Nasrollah

    2016-01-01

    Background: High level of stress in intensive care unit nurses affects the quality of their nursing care. Therefore, this study aimed to determine the effects of a stress management program on the quality of nursing care of intensive care unit nurses. Materials and Methods: This study is a randomized clinical trial that was conducted on 65 nurses. The samples were selected by stratified sampling of the nurses working in intensive care units 1, 2, 3 in Al-Zahra Hospital in Isfahan, Iran and were randomly assigned to two groups. The intervention group underwent an intervention, including 10 sessions of stress management that was held twice a week. In the control group, placebo sessions were held simultaneously. Data were gathered by demographic checklist and Quality Patient Care Scale before, immediately after, and 1 month after the intervention in both groups. Then, the data were analyzed by Student's t-test, Mann–Whitney, Chi-square, Fisher's exact test, and analysis of variance (ANOVA) through SPSS software version 18. Results: Mean scores of overall and dimensions of quality of care in the intervention group were significantly higher immediately after and 1 month after the intervention, compared to pre-intervention (P < 0.001). The results showed that the quality of care in the intervention group was significantly higher immediately after and 1 month after the intervention, compared to the control group (P < 0.001). Conclusions: As stress management is an effective method to improve the quality of care, the staffs are recommended to consider it in improvement of the quality of nursing care. PMID:27186196

  9. LED Lighting – Modification of Growth, Metabolism, Yield and Flour Composition in Wheat by Spectral Quality and Intensity

    PubMed Central

    Monostori, István; Heilmann, Márk; Kocsy, Gábor; Rakszegi, Marianna; Ahres, Mohamed; Altenbach, Susan B.; Szalai, Gabriella; Pál, Magda; Toldi, Dávid; Simon-Sarkadi, Livia; Harnos, Noémi; Galiba, Gábor; Darko, Éva

    2018-01-01

    The use of light-emitting diode (LED) technology for plant cultivation under controlled environmental conditions can result in significant reductions in energy consumption. However, there is still a lack of detailed information on the lighting conditions required for optimal growth of different plant species and the effects of light intensity and spectral composition on plant metabolism and nutritional quality. In the present study, wheat plants were grown under six regimens designed to compare the effects of LED and conventional fluorescent lights on growth and development, leaf photosynthesis, thiol and amino acid metabolism as well as grain yield and flour quality of wheat. Benefits of LED light sources over fluorescent lighting were manifested in both yield and quality of wheat. Elevated light intensities made possible with LEDs increased photosynthetic activity, the number of tillers, biomass and yield. At lower light intensities, blue, green and far-red light operated antagonistically during the stem elongation period. High photosynthetic activity was achieved when at least 50% of red light was applied during cultivation. A high proportion of blue light prolonged the juvenile phase, while the shortest flowering time was achieved when the blue to red ratio was around one. Blue and far-red light affected the glutathione- and proline-dependent redox environment in leaves. LEDs, especially in Blue, Pink and Red Low Light (RedLL) regimens improved flour quality by modifying starch and protein content, dough strength and extensibility as demonstrated by the ratios of high to low molecular weight glutenins, ratios of glutenins to gliadins and gluten spread values. These results clearly show that LEDs are efficient for experimental wheat cultivation, and make it possible to optimize the growth conditions and to manipulate metabolism, yield and quality through modification of light quality and quantity. PMID:29780400

  10. Generation of intense high-order vortex harmonics.

    PubMed

    Zhang, Xiaomei; Shen, Baifei; Shi, Yin; Wang, Xiaofeng; Zhang, Lingang; Wang, Wenpeng; Xu, Jiancai; Yi, Longqiong; Xu, Zhizhan

    2015-05-01

    This Letter presents for the first time a scheme to generate intense high-order optical vortices that carry orbital angular momentum in the extreme ultraviolet region based on relativistic harmonics from the surface of a solid target. In the three-dimensional particle-in-cell simulation, the high-order harmonics of the high-order vortex mode is generated in both reflected and transmitted light beams when a linearly polarized Laguerre-Gaussian laser pulse impinges on a solid foil. The azimuthal mode of the harmonics scales with its order. The intensity of the high-order vortex harmonics is close to the relativistic region, with the pulse duration down to attosecond scale. The obtained intense vortex beam possesses the combined properties of fine transversal structure due to the high-order mode and the fine longitudinal structure due to the short wavelength of the high-order harmonics. In addition to the application in high-resolution detection in both spatial and temporal scales, it also presents new opportunities in the intense vortex required fields, such as the inner shell ionization process and high energy twisted photons generation by Thomson scattering of such an intense vortex beam off relativistic electrons.

  11. Quality Improvement Process in a Large Intensive Care Unit: Structure and Outcomes.

    PubMed

    Reddy, Anita J; Guzman, Jorge A

    2016-11-01

    Quality improvement in the health care setting is a complex process, and even more so in the critical care environment. The development of intensive care unit process measures and quality improvement strategies are associated with improved outcomes, but should be individualized to each medical center as structure and culture can differ from institution to institution. The purpose of this report is to describe the structure of quality improvement processes within a large medical intensive care unit while using examples of the study institution's successes and challenges in the areas of stat antibiotic administration, reduction in blood product waste, central line-associated bloodstream infections, and medication errors. © The Author(s) 2015.

  12. Functional High-Intensity Circuit Training Improves Body Composition, Peak Oxygen Uptake, Strength, and Alters Certain Dimensions of Quality of Life in Overweight Women.

    PubMed

    Sperlich, Billy; Wallmann-Sperlich, Birgit; Zinner, Christoph; Von Stauffenberg, Valerie; Losert, Helena; Holmberg, Hans-Christer

    2017-01-01

    The effects of circuit-like functional high-intensity training (Circuit HIIT ) alone or in combination with high-volume low-intensity exercise (Circuit combined ) on selected cardio-respiratory and metabolic parameters, body composition, functional strength and the quality of life of overweight women were compared. In this single-center, two-armed randomized, controlled study, overweight women performed 9-weeks (3 sessions·wk -1 ) of either Circuit HIIT ( n = 11), or Circuit combined ( n = 8). Peak oxygen uptake and perception of physical pain were increased to a greater extent ( p < 0.05) by Circuit HIIT , whereas Circuit combined improved perception of general health more ( p < 0.05). Both interventions lowered body mass, body-mass-index, waist-to-hip ratio, fat mass, and enhanced fat-free mass; decreased ratings of perceived exertion during submaximal treadmill running; improved the numbers of push-ups, burpees, one-legged squats, and 30-s skipping performed, as well as the height of counter-movement jumps; and improved physical and social functioning, role of physical limitations, vitality, role of emotional limitations, and mental health to a similar extent (all p < 0.05). Either forms of these multi-stimulating, circuit-like, multiple-joint training can be employed to improve body composition, selected variables of functional strength, and certain dimensions of quality of life in overweight women. However, Circuit HIIT improves peak oxygen uptake to a greater extent, but with more perception of pain, whereas Circuit combined results in better perception of general health.

  13. Functional High-Intensity Circuit Training Improves Body Composition, Peak Oxygen Uptake, Strength, and Alters Certain Dimensions of Quality of Life in Overweight Women

    PubMed Central

    Sperlich, Billy; Wallmann-Sperlich, Birgit; Zinner, Christoph; Von Stauffenberg, Valerie; Losert, Helena; Holmberg, Hans-Christer

    2017-01-01

    The effects of circuit-like functional high-intensity training (CircuitHIIT) alone or in combination with high-volume low-intensity exercise (Circuitcombined) on selected cardio-respiratory and metabolic parameters, body composition, functional strength and the quality of life of overweight women were compared. In this single-center, two-armed randomized, controlled study, overweight women performed 9-weeks (3 sessions·wk−1) of either CircuitHIIT (n = 11), or Circuitcombined (n = 8). Peak oxygen uptake and perception of physical pain were increased to a greater extent (p < 0.05) by CircuitHIIT, whereas Circuitcombined improved perception of general health more (p < 0.05). Both interventions lowered body mass, body-mass-index, waist-to-hip ratio, fat mass, and enhanced fat-free mass; decreased ratings of perceived exertion during submaximal treadmill running; improved the numbers of push-ups, burpees, one-legged squats, and 30-s skipping performed, as well as the height of counter-movement jumps; and improved physical and social functioning, role of physical limitations, vitality, role of emotional limitations, and mental health to a similar extent (all p < 0.05). Either forms of these multi-stimulating, circuit-like, multiple-joint training can be employed to improve body composition, selected variables of functional strength, and certain dimensions of quality of life in overweight women. However, CircuitHIIT improves peak oxygen uptake to a greater extent, but with more perception of pain, whereas Circuitcombined results in better perception of general health. PMID:28420999

  14. High-intensity focused ultrasound ablation for treatment of hepatocellular carcinoma and hypersplenism: preliminary study.

    PubMed

    Zhu, Jing; Zhu, Hui; Mei, Zhechuan; Jin, Chengbing; Ran, Lifeng; Zhou, Kun; Yang, Wei; Zhang, Lian; She, Chaokun

    2013-10-01

    The purpose of this work was to preliminarily investigate the efficacy and safety of high-intensity focused ultrasound treatment of hepatocellular carcinoma and hypersplenism. Nine patients with hepatocellular carcinoma complicated by hypersplenism (5 male and 4 female; median age, 56 years; range, 51-66 years) were treated with ultrasound-guided high-intensity focused ultrasound. Complications were recorded. Laboratory examination and magnetic resonance imaging were used to evaluate the efficacy. After high-intensity focused ultrasound treatment, mean spleen ablation ± SD of 28.76% ± 6.1% was discovered; meanwhile, the white blood cell count, platelet count, and liver function of the patients were substantially improved during the follow-up period. In addition, symptoms such as epistaxis and gingival bleeding were ameliorated or even eliminated, and the quality of life was improved. Follow-up imaging showed a nonperfused volume in the spleen and an absence of a tumor blood supply at the treated lesions in the liver. For the first time to our knowledge, high-intensity focused ultrasound ablation was used to treat hepatocellular carcinoma complicated by hypersplenism. High-intensity focused ultrasound may be an effective and safe alternative for treatment of hepatocellular carcinoma complicated by hypersplenism, but further studies are necessary to clarify the mechanisms.

  15. Intensive Quality Assurance of Therapist Adherence to Behavioral Interventions for Adolescent Substance Use Problems

    ERIC Educational Resources Information Center

    Holth, Per; Torsheim, Torbjorn; Sheidow, Ashli J.; Ogden, Terje; Henggeler, Scott W.

    2011-01-01

    This study was a cross-cultural replication of a study that investigated therapist adherence to behavioral interventions as a result of an intensive quality assurance system which was integrated into Multisystemic Therapy (MST). Thirty-three therapists and eight supervisors were block randomized to either an Intensive Quality Assurance or a…

  16. Male crickets adjust ejaculate quality with both risk and intensity of sperm competition.

    PubMed

    Simmons, Leigh W; Denholm, Amy; Jackson, Chantelle; Levy, Esther; Madon, Ewa

    2007-10-22

    Sperm competition theory predicts that males should increase their expenditure on the ejaculate with increasing risk of sperm competition, but decrease their expenditure with increasing intensity. There is accumulating evidence for sperm competition theory, based on examinations of testes size and/or the numbers of sperm ejaculated. However, recent studies suggest that ejaculate quality can also be subject to selection by sperm competition. We used experimental manipulations of the risk and intensity of sperm competition in the cricket, Teleogryllus oceanicus. We found that males produced ejaculates with a greater percentage of live sperm when they had encountered a rival male prior to mating. However, when mating with a female that presented a high intensity of sperm competition, males did not respond to risk, but produced ejaculates with a reduced percentage of live sperm. Our data suggest that males exhibit a fine-tuned hierarchy of responses to these cues of sperm competition.

  17. Hospice Use and High-Intensity Care in Men Dying of Prostate Cancer

    PubMed Central

    Bergman, Jonathan; Saigal, Christopher S.; Lorenz, Karl A.; Hanley, Janet; Miller, David C.; Gore, John L.; Litwin, Mark S.

    2012-01-01

    Background Hospice programs improve the quality of life and quality of death for men dying of cancer. We sought to characterize hospice use by men dying of prostate cancer and to compare the use of high-intensity care between those who did or did not enroll in hospice. Methods We used linked Surveillance, Epidemiology, and End Results–Medicare data to identify a cohort of Medicare beneficiaries who died of prostate cancer between 1992 and 2005. We created 2 multivariable logistic regression models, one to identify factors associated with hospice use and one to determine the association of hospice use with the receipt of diagnostic and interventional procedures and physician visits at the end of life. Results Of 14 521 men dying of prostate cancer, 7646 (53%) used hospice for a median of 24 days. Multivariable modeling demonstrated that African American ethnicity (odds ratio [OR], 0.78; 95% confidence interval [CI], 0.68–0.88) and higher Charlson comorbidity index (OR, 0.49; 95% CI, 0.44–0.55) were associated with lower odds of hospice use, while having a partner (OR, 1.23; 95% CI, 1.14–1.32) and more recent year of death (OR, 1.12; 95% CI, 1.11–1.14) were associated with higher odds of hospice use. Men dying of prostate cancer who enrolled in hospice were less likely (OR, 0.82; 95% CI, 0.74–0.91) to receive high-intensity care, including intensive care unit admissions, inpatient stays, and multiple emergency department visits. Conclusions The proportion of individuals using hospice is increasing, but the timing of hospice referral remains poor. Those who enroll in hospice are less likely to receive high-intensity end-of-life care. PMID:20937914

  18. Hospital Quality And Intensity Of Spending: Is There An Association?

    PubMed Central

    Yasaitis, Laura; Fisher, Elliott S.; Skinner, Jonathan S.

    2009-01-01

    Numerous studies in the United States have examined the association between quality and spending at the regional level. In this paper we evaluate this relationship at the level of individual hospitals, which are a more natural unit of analysis for reporting on and improving accountability. For all of the quality indicators studied, the association with spending is either nil or negative. The absence of positive correlations suggests that some institutions achieve exemplary performance on quality measures in settings that feature lower intensity of care. This finding highlights the need for reporting information on both quality and spending. PMID:19460774

  19. [Concept for a department of intensive care].

    PubMed

    Nierhaus, A; de Heer, G; Kluge, S

    2014-10-01

    Demographic change and increasing complexity are among the reasons for high-tech critical care playing a major and increasing role in today's hospitals. At the same time, intensive care is one of the most cost-intensive departments in the hospital. To guarantee high-quality care, close cooperation of specialised intensive care staff with specialists of all other medical areas is essential. A network of the intensive care units within the hospital may lead to synergistic effects concerning quality of care, simultaneously optimizing the use of human and technical resources. Notwithstanding any organisational concepts, development and maintenance of the highest possible quality of care should be of overriding importance.

  20. Metabolic Reprogramming in Leaf Lettuce Grown Under Different Light Quality and Intensity Conditions Using Narrow-Band LEDs.

    PubMed

    Kitazaki, Kazuyoshi; Fukushima, Atsushi; Nakabayashi, Ryo; Okazaki, Yozo; Kobayashi, Makoto; Mori, Tetsuya; Nishizawa, Tomoko; Reyes-Chin-Wo, Sebastian; Michelmore, Richard W; Saito, Kazuki; Shoji, Kazuhiro; Kusano, Miyako

    2018-05-21

    Light-emitting diodes (LEDs) are an artificial light source used in closed-type plant factories and provide a promising solution for a year-round supply of green leafy vegetables, such as lettuce (Lactuca sativa L.). Obtaining high-quality seedlings using controlled irradiation from LEDs is critical, as the seedling health affects the growth and yield of leaf lettuce after transplantation. Because key molecular pathways underlying plant responses to a specific light quality and intensity remain poorly characterised, we used a multi-omics-based approach to evaluate the metabolic and transcriptional reprogramming of leaf lettuce seedlings grown under narrow-band LED lighting. Four types of monochromatic LEDs (one blue, two green and one red) and white fluorescent light (control) were used at low and high intensities (100 and 300 μmol·m -2 ·s -1 , respectively). Multi-platform mass spectrometry-based metabolomics and RNA-Seq were used to determine changes in the metabolome and transcriptome of lettuce plants in response to different light qualities and intensities. Metabolic pathway analysis revealed distinct regulatory mechanisms involved in flavonoid and phenylpropanoid biosynthetic pathways under blue and green wavelengths. Taken together, these data suggest that the energy transmitted by green light is effective in creating a balance between biomass production and the production of secondary metabolites involved in plant defence.

  1. Measuring the quality of therapeutic apheresis care in the pediatric intensive care unit.

    PubMed

    Sussmane, Jeffrey B; Torbati, Dan; Gitlow, Howard S

    2012-01-01

    Our goal was to measure the quality of care provided in the Pediatric Intensive Care Unit (PICU) during Therapeutic Apheresis (TA). We described the care as a step by step process. We designed a flow chart to carefully document each step of the process. We then defined each step with a unique clinical indictor (CI) that represented the exact task we felt provided quality care. These CIs were studied and modified for 1 year. We measured our performance in this process by the number of times we accomplished the CI vs. the total number of CIs that were to be performed. The degree of compliance, with these clinical indicators, was analyzed and used as a metric for quality by calculating how close the process is running exactly as planned or "in control." The Apheresis Process was in control (compliance) for 47% of the indicators, as measured in the aggregate for the first observational year. We then applied the theory of Total Quality Management (TQM) through our Design, Measure, Analyze, Improve, and Control (DMAIC) model. We were able to improve the process and bring it into control by increasing the compliance to > 99.74%, in the aggregate, for the third and fourth quarter of the second year. We have implemented TQM to increase compliance, thus control, of a highly complex and multidisciplinary Pediatric Intensive Care therapy. We have shown a reproducible and scalable measure of quality for a complex clinical process in the PICU, without additional capital expenditure. Copyright © 2011 Wiley-Liss, Inc.

  2. Health-Related Quality of Life in Chronic Pruritus: An Analysis Related to Disease Etiology, Clinical Skin Conditions and Itch Intensity.

    PubMed

    Warlich, Benjamin; Fritz, Fleur; Osada, Nani; Bruland, Philipp; Stumpf, Astrid; Schneider, Gudrun; Dugas, Martin; Pfleiderer, Bettina; Ständer, Sonja

    2015-01-01

    It is unknown if health-related quality of life (HRQoL) differs between diseases associated with chronic pruritus (CP). To analyze HRQoL in relation to age, gender, skin lesions (primary vs. scratch-induced secondary) and itch intensity. Consecutive patients of our itch clinic were assessed with the Dermatology Life Quality Index (DLQI) and visual analogue scale (VAS). In 510 CP patients (282 females; median age, 61.4 years), DLQI scores and VAS values were highly correlated, irrespective of the type of skin lesion. Overall, women had a lower HRQoL compared to men (females: 10.7 ± 6.7, males: 8.9 ± 6.7), but female gender was only associated with worse quality of life in patients <65 years old. HRQoL impairment in CP is highly influenced by pruritus intensity but not to the visible skin lesion or underlying cause. With limitations to item bias, DLQI is a suitable instrument for estimating quality of life impairment by CP. © 2015 S. Karger AG, Basel.

  3. Exposure to high stress in the intensive care unit may have negative effects on health-related quality-of-life outcomes after cardiac surgery.

    PubMed

    Schelling, Gustav; Richter, Markus; Roozendaal, Benno; Rothenhäusler, Hans-Bernd; Krauseneck, Till; Stoll, Christian; Nollert, Georg; Schmidt, Michael; Kapfhammer, Hans-Peter

    2003-07-01

    Up to 20% of patients do not show improvements in health-related quality of life (HRQL) after cardiac surgery, despite apparently successful surgical procedures. We sought to determine whether failed improvements in HRQL after cardiac surgery are associated with the development of traumatic memories and chronic stress states as a result of high perioperative stress exposure. Prospective cohort study. A 10-bed cardiovascular intensive care unit of a tertiary care university hospital. A total of 148 cardiac surgical patients. None. The patients were evaluated for traumatic memories from postoperative treatment in the cardiovascular intensive care unit (defined as the subjective recollection of pain, respiratory distress, anxiety/panic, and nightmares), symptoms of chronic stress, including those of posttraumatic stress disorder, and HRQL preoperatively (at baseline) and at 6 months after cardiac surgery. A state of chronic stress was defined as the development of posttraumatic stress disorder at 6 months after surgery. Factors predicting the decline in HRQL were determined by multivariable linear regression. Twenty-seven patients (18.2%) had posttraumatic stress disorder at 6 months after cardiac surgery; seven of these patients (4.8%) had evidence of preexisting posttraumatic stress disorder before undergoing cardiac surgery. Patients with new posttraumatic stress disorder at 6 months after cardiac surgery had a significantly higher number of traumatic memories from postoperative treatment in the cardiovascular intensive care unit (p =.01). A multiple regression model included the number of traumatic memories from the intensive care unit and stress symptom scores at 6 months after heart surgery as predictors for variations in physical HRQL outcome scores (R2 =.30, p <.04). Stress symptom scores were the most significant predictors of mental health HRQL outcomes (R2 =.52, p <.01). Exposure to high stress in the cardiovascular intensive care unit can have negative

  4. Effect of High-Intensity Interval Versus Continuous Exercise Training on Functional Capacity and Quality of Life in Patients With Coronary Artery Disease: A RANDOMIZED CLINICAL TRIAL.

    PubMed

    Jaureguizar, Koldobika Villelabeitia; Vicente-Campos, Davinia; Bautista, Lorena Ruiz; de la Peña, Cesar Hernández; Gómez, María José Arriaza; Rueda, María José Calero; Fernández Mahillo, Ignacio

    2016-01-01

    There is strong evidence that exercise training has beneficial health effects in patients with cardiovascular disease. Most studies have focused on moderate continuous training (MCT); however, a body of evidence has begun to emerge demonstrating that high-intensity interval training (HIIT) has significantly better results in terms of morbidity and mortality. The aim of this study was to compare the effects of MCT versus HIIT on functional capacity and quality of life and to assess safety. Seventy-two patients with ischemic heart disease were assigned to either HIIT or MCT for 8 weeks. We analyzed cardiopulmonary exercise test data, quality of life, and adverse events. High-intensity interval training resulted in a significantly greater increase in (Equation is included in full-text article.)O2peak (4.5 ± 4.7 mL·kg·min) compared with MCT (2.5 ± 3.6 mL·kg·min) (P < .05). The aerobic threshold (VT1) increased by 21% in HIIT and 14% in MCT. Furthermore, there was a significant (P < .05) increase in the distance covered in the 6-minute walk distance test in the HIIT group (49.6 ± 6.3 m) when compared with the MCT group (29.6 ± 12.0 m). Both training protocols improved quality of life. No adverse events were reported in either of the groups. On the basis of the results of this study, HIIT should be considered for use in cardiac rehabilitation as it resulted in a greater increase in functional capacity compared with MCT. We also observed greater improvement in quality of life without any increase in cardiovascular risk.

  5. Eliciting the Intension of Drug Value Sets – Principles and Quality Assurance Applications

    PubMed Central

    Bahr, Nathan J.; Nelson, Scott D.; Winnenburg, Rainer; Bodenreider, Olivier

    2018-01-01

    Value sets (VSs) used in electronic clinical quality measures are lists of codes from standard terminologies (“extensional” VSs), whose purpose (“intension”) is not always explicitly stated. We elicited the intension for the 09/01/2014 release of extensional medication value sets by comparison to drug classes from the October 2014 release of RxClass. Value sets matched drug classes if they shared common ingredients, as evidenced by Jaccard similarity score. We elicited the intension of 80 extensional value sets. The average Jaccard similarity was 0.65 for single classes and 0.80 for combination classes, with 34% (27/80) of the value sets having high similarity scores. Manual review by a pharmacist indicated 51% (41/80) of the drug classes selected as the best mapping for a value set matched the intension reflected in that value set name. This approach has the potential for facilitating the development and maintenance of medication value sets. PMID:29295218

  6. High-frequency, high-intensity photoionization

    NASA Astrophysics Data System (ADS)

    Reiss, H. R.

    1996-02-01

    Two analytical methods for computing ionization by high-frequency fields are compared. Predicted ionization rates compare well, but energy predictions for the onset of ionization differ radically. The difference is shown to arise from the use of a transformation in one of the methods that alters the zero from which energy is measured. This alteration leads to an apparent energy threshold for ionization that can, especially in the stabilization regime, differ strongly from the laboratory measurement. It is concluded that channel closings in intense-field ionization can occur at high as well as low frequencies. It is also found that the stabilization phenomenon at high frequencies, very prominent for hydrogen, is absent in a short-range potential.

  7. Structural relationships between work environment and service quality perceptions as a function of customer contact intensity: implications for human service strategy.

    PubMed

    Scotti, Dennis J; Harmon, Joel; Behson, Scott J

    2009-01-01

    This study assesses the importance of customer-contact intensity at the service encounter level as a determinant of service quality assessments. Using data from the U.S. Department of Veterans Affairs, it shows that performance-driven human resources practices play an important role as determinants of employee customer orientation and service capability in both high-contact (outpatient healthcare) and low-contact (benefits claim processing) human service contexts. However, there existed significant differences across service delivery settings in the salience of customer orientation and the congruence between employee and customer perceptions of service quality, depending on the intensity of customer contact. In both contexts, managerial attention to high-performance work systems and customer-orientation has the potential to favorably impact perceptions of service quality, amplify consumer satisfaction, and enhance operational efficiency.

  8. Quality of care in the intensive care unit from the perspective of patient's relatives: development and psychometric evaluation of the consumer quality index 'R-ICU'.

    PubMed

    Rensen, Ans; van Mol, Margo M; Menheere, Ilse; Nijkamp, Marjan D; Verhoogt, Ellen; Maris, Bea; Manders, Willeke; Vloet, Lilian; Verharen, Lisbeth

    2017-01-24

    The quality standards of the Dutch Society of Intensive Care require monitoring of the satisfaction of patient's relatives with respect to care. Currently, no suitable instrument is available in the Netherlands to measure this. This study describes the development and psychometric evaluation of the questionnaire-based Consumer Quality Index 'Relatives in Intensive Care Unit' (CQI 'R-ICU'). The CQI 'R-ICU' measures the perceived quality of care from the perspective of patients' relatives, and identifies aspects of care that need improvement. The CQI 'R-ICU' was developed using a mixed method design. Items were based on quality of care aspects from earlier studies and from focus group interviews with patients' relatives. The time period for the data collection of the psychometric evaluation was from October 2011 until July 2012. Relatives of adult intensive care patients in one university hospital and five general hospitals in the Netherlands were approached to participate. Psychometric evaluation included item analysis, inter-item analysis, and factor analysis. Twelve aspects were noted as being indicators of quality of care, and were subsequently selected for the questionnaire's vocabulary. The response rate of patients' relatives was 81% (n = 455). Quality of care was represented by two clusters, each showing a high reliability: 'Communication' (α = .80) and 'Participation' (α = .84). Relatives ranked the following aspects for quality of care as most important: no conflicting information, information from doctors and nurses is comprehensive, and health professionals take patients' relatives seriously. The least important care aspects were: need for contact with peers, nuisance, and contact with a spiritual counsellor. Aspects that needed the most urgent improvement (highest quality improvement scores) were: information about how relatives can contribute to the care of the patient, information about the use of meal-facilities in the hospital, and

  9. High power, high beam quality regenerative amplifier

    DOEpatents

    Hackel, L.A.; Dane, C.B.

    1993-08-24

    A regenerative laser amplifier system generates high peak power and high energy per pulse output beams enabling generation of X-rays used in X-ray lithography for manufacturing integrated circuits. The laser amplifier includes a ring shaped optical path with a limited number of components including a polarizer, a passive 90 degree phase rotator, a plurality of mirrors, a relay telescope, and a gain medium, the components being placed close to the image plane of the relay telescope to reduce diffraction or phase perturbations in order to limit high peak intensity spiking. In the ring, the beam makes two passes through the gain medium for each transit of the optical path to increase the amplifier gain to loss ratio. A beam input into the ring makes two passes around the ring, is diverted into an SBS phase conjugator and proceeds out of the SBS phase conjugator back through the ring in an equal but opposite direction for two passes, further reducing phase perturbations. A master oscillator inputs the beam through an isolation cell (Faraday or Pockels) which transmits the beam into the ring without polarization rotation. The isolation cell rotates polarization only in beams proceeding out of the ring to direct the beams out of the amplifier. The diffraction limited quality of the input beam is preserved in the amplifier so that a high power output beam having nearly the same diffraction limited quality is produced.

  10. High power, high beam quality regenerative amplifier

    DOEpatents

    Hackel, Lloyd A.; Dane, Clifford B.

    1993-01-01

    A regenerative laser amplifier system generates high peak power and high energy per pulse output beams enabling generation of X-rays used in X-ray lithography for manufacturing integrated circuits. The laser amplifier includes a ring shaped optical path with a limited number of components including a polarizer, a passive 90 degree phase rotator, a plurality of mirrors, a relay telescope, and a gain medium, the components being placed close to the image plane of the relay telescope to reduce diffraction or phase perturbations in order to limit high peak intensity spiking. In the ring, the beam makes two passes through the gain medium for each transit of the optical path to increase the amplifier gain to loss ratio. A beam input into the ring makes two passes around the ring, is diverted into an SBS phase conjugator and proceeds out of the SBS phase conjugator back through the ring in an equal but opposite direction for two passes, further reducing phase perturbations. A master oscillator inputs the beam through an isolation cell (Faraday or Pockels) which transmits the beam into the ring without polarization rotation. The isolation cell rotates polarization only in beams proceeding out of the ring to direct the beams out of the amplifier. The diffraction limited quality of the input beam is preserved in the amplifier so that a high power output beam having nearly the same diffraction limited quality is produced.

  11. Intensive Quality Assurance of Therapist Adherence to Behavioral Interventions for Adolescent Substance Use Problems.

    PubMed

    Holth, Per; Torsheim, Torbjørn; Sheidow, Ashli J; Ogden, Terje; Henggeler, Scott W

    2011-01-01

    This study was a crosscultural replication of a study that investigated therapist adherence to behavioral interventions as a result of an intensive quality assurance system which was integrated into Multisystemic Therapy. Thirty-three therapists and eight supervisors participated in the study and were block randomized to either an Intensive Quality Assurance or a Workshop Only condition. Twenty-one of these therapists treated 41 cannabis-abusing adolescents and their families. Therapist adherence and youth drug screens were collected during a five-month baseline period prior to the workshop on contingency management and during 12 months post workshop. The results replicated the previous finding that therapist adherence to the cognitive-behavioral interventions, but not to contingency management, showed a strong positive difference in trend in favor of the intensive quality assurance condition. While the clinical impact of such quality assurance may be delayed and remains to be demonstrated, cannabis abstinence increased as a function of time in therapy, and was more likely with stronger therapy adherence to contingency management, but did not differ across quality assurance interventions.

  12. Repeated high-intensity exercise in professional rugby union.

    PubMed

    Austin, Damien; Gabbett, Tim; Jenkins, David

    2011-07-01

    The aim of the present study was to describe the frequency, duration, and nature of repeated high-intensity exercise in Super 14 rugby union. Time-motion analysis was used during seven competition matches over the 2008 and 2009 Super 14 seasons; five players from each of four positional groups (front row forwards, back row forwards, inside backs, and outside backs) were assessed (20 players in total). A repeated high-intensity exercise bout was considered to involve three or more sprints, and/or tackles and/or scrum/ruck/maul activities within 21 s during the same passage of play. The range of repeated high-intensity exercise bouts for each group in a match was as follows: 11-18 for front row forwards, 11-21 for back row forwards, 13-18 for inside backs, and 2-11 for outside backs. The durations of the most intense repeated high-intensity exercise bouts for each position ranged from 53 s to 165 s and the minimum recovery periods between repeated high-intensity exercise bouts ranged from 25 s for the back row forwards to 64 s for the front row forwards. The present results show that repeated high-intensity exercise bouts vary in duration and activities relative to position but all players in a game will average at least 10 changes in activity in the most demanding bouts and complete at least one tackle and two sprints. The most intense periods of activity are likely to last as long as 120 s and as little as 25 s recovery may separate consecutive repeated high-intensity exercise bouts. The present findings can be used by coaches to prepare their players for the most demanding passages of play likely to be experienced in elite rugby union.

  13. Auxin-to-Gibberellin Ratio as a Signal for Light Intensity and Quality in Regulating Soybean Growth and Matter Partitioning

    PubMed Central

    Yang, Feng; Fan, Yuanfang; Wu, Xiaoling; Cheng, Yajiao; Liu, Qinlin; Feng, Lingyang; Chen, Junxu; Wang, Zhonglin; Wang, Xiaochun; Yong, Taiwen; Liu, Weiguo; Liu, Jiang; Du, Junbo; Shu, Kai; Yang, Wenyu

    2018-01-01

    The intensity and quality (red to far-red (R/Fr) ratio) of light directly affect growth of plant under shading. Gibberellins (GAs) and auxin [indole-3-acetic acid (IAA)] play important roles in mediating the shading adaptive responses of plants. Thus, the intensity and quality of the uncoupling light from shading were assessed to identify the influence of each component on the morphology and matter distribution of the leaf, stem, and petiole. This assessment was based on the changes in endogenous Gibberellin 1 (GA1) and IAA levels. Soybean plants were grown in a growth chamber with four treatments [normal (N), N+Fr, low (L), and L+Fr light]. Results revealed that the reductions in photosynthetically active radiation (PAR) and R/Fr ratio equally increased height and stem mass fractions (SMFs) of the soybean seedling. The light intensity significantly influenced the dry mass per unit area and mass fraction of soybean leaves, whereas the light quality regulated the petiole elongation and mass fraction. Low R/Fr ratio (high Fr light) increased the soybean biomass by improving the photosynthetic assimilation rate and quantum yield of photosystem II. In addition, the IAA and GA1 levels in the leaf, stem, and petiole did not reflect the growth response trends of each tissue toward light intensity and quality; however, trends of the IAA-to-GA1 content ratios were similar to those of the growth and matter allocation of each soybean tissue under different light environments. Therefore, the response of growth and matter allocation of soybean to light intensity and quality may be regulated by the IAA-to-GA1 content ratio in the tissues of the soybean plant. PMID:29441084

  14. Factors Affecting Sleep Quality of Patients in Intensive Care Unit

    PubMed Central

    Bihari, Shailesh; Doug McEvoy, R.; Matheson, Elisha; Kim, Susan; Woodman, Richard J.; Bersten, Andrew D.

    2012-01-01

    Introduction: Sleep disturbance is a frequently overlooked complication of intensive care unit (ICU) stay. Aim: To evaluate sleep quality among patients admitted to ICU and investigate environmental and non-environmental factors that affect sleep quality in ICU. Methods: Over a 22-month period, we consecutively recruited patients who spent ≥ 2 nights post-endotracheal extubation in ICU and who were orientated to time, place, and person on the day of discharge. Self-reported sleep quality, according to a modified Freedman questionnaire, which provided data on self-reported ICU sleep quality in ICU and environmental factors affecting sleep quality in the ICU, were collected. We also investigated non-environmental factors, such as severity of illness, ICU interventions, and medications that can affect sleep quality. Results: Fifty males and 50 females were recruited with a mean (± SD) age of 65.1 ± 15.2 years. APACHE II score at admission to ICU was 18.1 ± 7.5 with duration of stay 6.7 ± 6.5days. Self-reported sleep quality score at home (1 = worst; 10 = best) was 7.0 ± 2.2; this decreased to 4.0 ± 1.7 during their stay in ICU (p < 0.001). In multivariate analysis with APACHE III as severity of illness (R2 = 0.25), factors [exp(b)(95% CI), p value] which significantly affected sleep in ICU were sex [0.37(0.19-0.72), p < 0.01], age and sex interaction [1.02(1.01-1.03), p < 0.01], bedside phone [0.92(0.87-0.97), p < 0.01], prior quality of sleep at home [1.30(1.05-1.62), p = 0.02], and use of steroids [0.82(0.69-0.98), p = 0.03] during the stay in ICU. Conclusion: Reduced sleep quality is a common problem in ICU with a multifactorial etiology. Citation: Bihari S; McEvoy RD; Kim S; Woodman RJ; Bersten AD. Factors affecting sleep quality of patients in intensive care unit. J Clin Sleep Med 2012;8(3):301-307. PMID:22701388

  15. Photon-photon scattering at the high-intensity frontier

    NASA Astrophysics Data System (ADS)

    Gies, Holger; Karbstein, Felix; Kohlfürst, Christian; Seegert, Nico

    2018-04-01

    The tremendous progress in high-intensity laser technology and the establishment of dedicated high-field laboratories in recent years have paved the way towards a first observation of quantum vacuum nonlinearities at the high-intensity frontier. We advocate a particularly prospective scenario, where three synchronized high-intensity laser pulses are brought into collision, giving rise to signal photons, whose frequency and propagation direction differ from the driving laser pulses, thus providing various means to achieve an excellent signal to background separation. Based on the theoretical concept of vacuum emission, we employ an efficient numerical algorithm which allows us to model the collision of focused high-intensity laser pulses in unprecedented detail. We provide accurate predictions for the numbers of signal photons accessible in experiment. Our study is the first to predict the precise angular spread of the signal photons, and paves the way for a first verification of quantum vacuum nonlinearity in a well-controlled laboratory experiment at one of the many high-intensity laser facilities currently coming online.

  16. Automation and Intensity Modulated Radiation Therapy for Individualized High-Quality Tangent Breast Treatment Plans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Purdie, Thomas G., E-mail: Tom.Purdie@rmp.uhn.on.ca; Department of Radiation Oncology, University of Toronto, Toronto, Ontario; Techna Institute, University Health Network, Toronto, Ontario

    Purpose: To demonstrate the large-scale clinical implementation and performance of an automated treatment planning methodology for tangential breast intensity modulated radiation therapy (IMRT). Methods and Materials: Automated planning was used to prospectively plan tangential breast IMRT treatment for 1661 patients between June 2009 and November 2012. The automated planning method emulates the manual steps performed by the user during treatment planning, including anatomical segmentation, beam placement, optimization, dose calculation, and plan documentation. The user specifies clinical requirements of the plan to be generated through a user interface embedded in the planning system. The automated method uses heuristic algorithms to definemore » and simplify the technical aspects of the treatment planning process. Results: Automated planning was used in 1661 of 1708 patients receiving tangential breast IMRT during the time interval studied. Therefore, automated planning was applicable in greater than 97% of cases. The time for treatment planning using the automated process is routinely 5 to 6 minutes on standard commercially available planning hardware. We have shown a consistent reduction in plan rejections from plan reviews through the standard quality control process or weekly quality review multidisciplinary breast rounds as we have automated the planning process for tangential breast IMRT. Clinical plan acceptance increased from 97.3% using our previous semiautomated inverse method to 98.9% using the fully automated method. Conclusions: Automation has become the routine standard method for treatment planning of tangential breast IMRT at our institution and is clinically feasible on a large scale. The method has wide clinical applicability and can add tremendous efficiency, standardization, and quality to the current treatment planning process. The use of automated methods can allow centers to more rapidly adopt IMRT and enhance access to the documented

  17. Automation and intensity modulated radiation therapy for individualized high-quality tangent breast treatment plans.

    PubMed

    Purdie, Thomas G; Dinniwell, Robert E; Fyles, Anthony; Sharpe, Michael B

    2014-11-01

    To demonstrate the large-scale clinical implementation and performance of an automated treatment planning methodology for tangential breast intensity modulated radiation therapy (IMRT). Automated planning was used to prospectively plan tangential breast IMRT treatment for 1661 patients between June 2009 and November 2012. The automated planning method emulates the manual steps performed by the user during treatment planning, including anatomical segmentation, beam placement, optimization, dose calculation, and plan documentation. The user specifies clinical requirements of the plan to be generated through a user interface embedded in the planning system. The automated method uses heuristic algorithms to define and simplify the technical aspects of the treatment planning process. Automated planning was used in 1661 of 1708 patients receiving tangential breast IMRT during the time interval studied. Therefore, automated planning was applicable in greater than 97% of cases. The time for treatment planning using the automated process is routinely 5 to 6 minutes on standard commercially available planning hardware. We have shown a consistent reduction in plan rejections from plan reviews through the standard quality control process or weekly quality review multidisciplinary breast rounds as we have automated the planning process for tangential breast IMRT. Clinical plan acceptance increased from 97.3% using our previous semiautomated inverse method to 98.9% using the fully automated method. Automation has become the routine standard method for treatment planning of tangential breast IMRT at our institution and is clinically feasible on a large scale. The method has wide clinical applicability and can add tremendous efficiency, standardization, and quality to the current treatment planning process. The use of automated methods can allow centers to more rapidly adopt IMRT and enhance access to the documented improvements in care for breast cancer patients, using

  18. Quality of Life After Hypofractionated Concomitant Intensity-Modulated Radiotherapy Boost for High-Risk Prostate Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quon, Harvey; Department of Radiation Oncology, University of Toronto, Toronto, ON; Cheung, Patrick C.F., E-mail: patrick.cheung@sunnybrook.ca

    Purpose: To evaluate the change in health-related quality of life (QOL) of patients with high-risk prostate cancer treated using hypofractionated radiotherapy combined with long-term androgen deprivation therapy. Methods and Materials: A prospective Phase I-II study enrolled patients with any of the following: clinical Stage T3 disease, prostate-specific antigen level {>=}20 ng/mL, or Gleason score 8-10. Radiotherapy consisted of 45 Gy (1.8 Gy per fraction) to the pelvic lymph nodes with a concomitant 22.5 Gy intensity-modulated radiotherapy boost to the prostate, for a total of 67.5 Gy (2.7 Gy per fraction) in 25 fractions over 5 weeks. Daily image guidance wasmore » performed using three gold seed fiducials. Quality of life was measured using the Expanded Prostate Cancer Index Composite (EPIC), a validated tool that assesses four primary domains (urinary, bowel, sexual, and hormonal). Results: From 2004 to 2007, 97 patients were treated. Median follow-up was 39 months. Compared with baseline, at 24 months there was no statistically significant change in the mean urinary domain score (p = 0.99), whereas there were decreases in the bowel (p < 0.01), sexual (p < 0.01), and hormonal (p < 0.01) domains. The proportion of patients reporting a clinically significant difference in EPIC urinary, bowel, sexual, and hormonal scores at 24 months was 27%, 31%, 55%, and 60%, respectively. However, moderate and severe distress related to these symptoms was minimal, with increases of only 3% and 5% in the urinary and bowel domains, respectively. Conclusions: Hypofractionated radiotherapy combined with long-term androgen deprivation therapy was well tolerated. Although there were modest rates of clinically significant patient-reported urinary and bowel toxicity, most of this caused only mild distress, and moderate and severe effects on QOL were limited. Additional follow-up is ongoing to characterize long-term QOL.« less

  19. Feasibility and effects of a combined adjuvant high-intensity interval/strength training in breast cancer patients: a single-center pilot study.

    PubMed

    Schulz, Sebastian Viktor Waldemar; Laszlo, Roman; Otto, Stephanie; Prokopchuk, Dmytro; Schumann, Uwe; Ebner, Florian; Huober, Jens; Steinacker, Jürgen Michael

    2018-06-01

    To evaluate feasibility of an exercise intervention consisting of high-intensity interval endurance and strength training in breast cancer patients. Twenty-six women with nonmetastatic breast cancer were consecutively assigned to the exercise intervention- (n= 15, mean age 51.9 ± 9.8 years) and the control group (n = 11, mean age 56.9 ± 7.0 years). Cardiopulmonary exercise testing that included lactate sampling, one-repetition maximum tests and a HADS-D questionnaire were used to monitor patients both before and after a supervised six weeks period of either combined high-intensity interval endurance and strength training (intervention group, twice a week) or leisure training (control group). Contrarily to the control group, endurance (mean change of VO 2 , peak 12.0 ± 13.0%) and strength performance (mean change of cumulative load 25.9 ± 11.2%) and quality of life increased in the intervention group. No training-related adverse events were observed. Our guided exercise intervention could be used effectively for initiation and improvement of performance capacity and quality of life in breast cancer patients in a relatively short time. This might be especially attractive during medical treatment. Long-term effects have to be evaluated in randomized controlled studies also with a longer follow-up. Implications for Rehabilitation High-intensity interval training allows improvement of aerobic capacity within a comparable short time. Standard leisure training in breast cancer patients is rather suitable for the maintenance of performance capacity and quality of life. Guided high-intensity interval training combined with strength training can be used effectively for the improvement of endurance and strength capacity and also quality of life. After exclusion of contraindications, guided adjuvant high-intensity interval training combined with strength training can be safely used in breast cancer patients.

  20. Differences in Pain Location, Intensity and Quality by Pain Pattern in Outpatients with Cancer

    PubMed Central

    Ngamkham, Srisuda; Holden, Janean E.; Wilkie, Diana J.

    2013-01-01

    Pain pattern represents how the individual’s pain changes temporally with activities or other factors. Understanding pain pattern is important for appropriate timing of pain interventions, but researchers have studied less the temporal aspects of cancer pain than pain location, intensity, and quality parameters. The study purpose was to explore differences in pain location, intensity, and quality by pattern groups in outpatients with cancer. We conducted a comparative, secondary data analysis of data collected from 1994 to 2007. 762 outpatients with cancer had completed the 0-to-10 Pain Intensity Number Scale and the McGill Pain Questionnaire to measure pain location, quality and pattern. From all possible combinations of the three types of pain patterns, we created seven pain pattern groups. The distribution of pain pattern was: pattern-1 (27%); pattern-2 (24%); pattern-3 (8%); pattern-4 (12%); pattern-5 (3%); pattern-6 (18%); and pattern-7 (8%). A statistically significant higher proportion of patients with continuous pain patterns (pattern 1, 4, 5, and 7) reported pain location in two or more sites. Patients with pattern 1, 4, and 7 reported statistically significant, higher worst pain mean scores than patients with pattern 2, 3, and 6 (not continuous descriptors). Patients with pattern7 reported statistically significant, higher mean scores (pain rating index-sensory and total number of words selected) than patients with pattern1, 2, 3, 4, and 6. Using pain pattern groups may help clinicians to understand temporal changes in cancer pain and to provide more effective pain management by recognizing the high risk if the pain is continuous. PMID:21512345

  1. Salutary effects of high-intensity interval training in persons with elevated cardiovascular risk.

    PubMed

    Fleg, Jerome L

    2016-01-01

    Although moderate-intensity continuous training (MICT) has been the traditional model for aerobic exercise training for over four decades, a growing body of literature has demonstrated equal if not greater improvement in aerobic capacity and similar beneficial effects on body composition, glucose metabolism, blood pressure, and quality of life from high-intensity interval training (HIIT). An advantage of HIIT over MICT is the shorter time required to perform the same amount of energy expenditure. The current brief review summarizes the effects of HIIT on peak aerobic capacity and cardiovascular risk factors in healthy adults and those with various cardiovascular diseases, including coronary artery disease, chronic heart failure, and post heart transplantation.

  2. Water-cooled, high-intensity ultrasound surgical applicators with frequency tracking.

    PubMed

    Martin, Roy W; Vaezy, Shahram; Proctor, Andrew; Myntti, Terrence; Lee, Janelle B J; Crum, Lawrence A

    2003-10-01

    High-intensity, focused ultrasound (HIFU) applicators have been developed for arresting bleeding with the ultimate intent of use in surgery. The design uses a tapered titanium component for transmission coupling of the ultrasound energy from a spherically curved transducer to biological tissues. The nominal operating frequency is 5.5 MHz, in a highly resonant mode (quality factor of 327 with water load). Liquid cooling is used to remove energy loss important at net applied power greater than 18 W/cm2 at the surface of the piezoelectric element. A downward resonance frequency shift (>20 kHz) occurs, even with cooling, as the applicator warms with normal operation. A feedback technique is used for maintaining the excitation near optimum resonance. Standing wave ratios of the applied power of 1.6 or less are thus sustained. The system and applicators have been found to be highly robust, effective in achieving hemostasis in the hemorrhaging liver, spleen, lung, or blood vessels in rabbit and pig experiments. One unit has been operated for over 1.7 hours in treating organ hemorrhage in blunt trauma experiments with nine swine with electrical net power of up to 158 W (31 W/cm2 across the transducer) and intensity of 2560 W/cm2 at focus.

  3. The effects of high intensity interval training on muscle size and quality in overweight and obese adults.

    PubMed

    Blue, Malia N M; Smith-Ryan, Abbie E; Trexler, Eric T; Hirsch, Katie R

    2018-02-01

    Despite growing popularity of high intensity interval training (HIIT) for improving health and fitness, limited data exist identifying the effects of HIIT on muscle characteristics. The purpose of the current study was to investigate the effects of a 3-week HIIT intervention on muscle size and quality in overweight and obese men and women. Randomized controlled trial. Forty-four overweight and obese men and women (mean±SD; age: 35.4±12.3years; height: 174.9±9.7cm; weight: 94.6±17.0kg; %fat: 32.7±6.5%) completed the current study. During baseline and post testing, muscle cross sectional area (mCSA) and echo intensity (EI) were determined from a panoramic scan of the vastus lateralis obtained by B-mode ultrasonography. Body composition variables were measured using dual energy X-ray absorptiometry. Participants were randomized into either a 1:1 work-to-rest ratio HIIT group (SIT; n=16), a 2:1 work-to-rest ratio HIIT group (LIT; n=19), or control (CON; n=9). HIIT participants performed five, 2-min bouts (LIT) or 10, 1-min bouts (SIT) at 85-100% VO 2peak for 9 sessions over three weeks. Analysis of covariance demonstrated a significant increase in mCSA for SIT (p=0.038; change (Δ)=3.17±3.36cm 2 ) compared to CON (Δ=-0.34±2.36cm 2 ). There was no significant difference in EI across groups (p=0.672). HIIT may be an effective exercise modality to influence muscle size in overweight and obese individuals. Future studies should investigate muscle characteristics and remodeling in an overweight population following interventions of longer duration and varying work-to-rest protocols. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  4. Asymptomatic Carotid T1-High-Intense Plaque as a Risk Factor for a Subsequent Cerebrovascular Ischemic Event.

    PubMed

    Kurosaki, Yoshitaka; Yoshida, Kazumichi; Fukuda, Hitoshi; Handa, Akira; Chin, Masaki; Yamagata, Sen

    2017-01-01

    Intraplaque hemorrhage, detected as a high-signal intensity on carotid MRI, is also strongly associated with ischemic events in symptomatic patients. However, in asymptomatic patients, the relationship of the T1-high intense plaque and the subsequent stroke is not clear. The aim of this study is to test the hypothesis that asymptomatic carotid T1-high intense plaque is a risk factor for a subsequent cerebrovascular ischemic event. Of the 1,353 consecutive patients, who underwent head and carotid MRI as part of their annual medical check-up, the imaging quality of 13 was poor and 150 did not present for follow-up examination, thus leaving 1,190 subjects for evaluation. Of the 1,190 patients, 96 patients had findings of high-signal intensity on carotid MRI and 1,094 patients did not. Cerebrovascular events were retrospectively evaluated. During a mean follow-up period of 53 months, 4 patients with high-signal intensities on carotid MRI (4%) and 3 with no findings (0.3%) had a cerebrovascular ischemic event, with the occurrences significantly higher in the high-signal-intensity group. (p < 0.01) Cox regression analysis indicated that the presence of the high-intense plaque on carotid MRI (hazard ratio [HR] 4.2; 95% CI 1.0-17.1; p = 0.04), age (HR 1.1; 95% CI 1.0-1.2; p = 0.003), and diabetes mellitus (HR 7.2; 95% CI 1.8-27.4; p = 0.004) were associated with the occurrence of subsequent ischemic cerebrovascular events. Asymptomatic carotid T1-high-intense plaque might be a potential high-risk factor for a subsequent cerebrovascular ischemic event. © 2017 S. Karger AG, Basel.

  5. High-intensity interval training evokes larger serum BDNF levels compared with intense continuous exercise.

    PubMed

    Saucedo Marquez, Cinthia Maria; Vanaudenaerde, Bart; Troosters, Thierry; Wenderoth, Nicole

    2015-12-15

    Exercise can have a positive effect on the brain by activating brain-derived neurotrophic factor (BDNF)-related processes. In healthy humans there appears to be a linear relationship between exercise intensity and the positive short-term effect of acute exercise on BDNF levels (i.e., the highest BDNF levels are reported after high-intensity exercise protocols). Here we performed two experiments to test the effectiveness of two high-intensity exercise protocols, both known to improve cardiovascular health, to determine whether they have a similar efficacy in affecting BDNF levels. Participants performed a continuous exercise (CON) protocol at 70% of maximal work rate and a high-intensity interval-training (HIT) protocol at 90% of maximal work rate for periods of 1 min alternating with 1 min of rest (both protocols lasted 20 min). We observed similar BDNF kinetics in both protocols, with maximal BDNF concentrations being reached toward the end of training (experiment 1). We then showed that both exercise protocols significantly increase BDNF levels compared with a rest condition (CON P = 0.04; HIT P < 0.001), with HIT reaching higher BDNF levels than CON (P = 0.035) (experiment 2). These results suggest that shorter bouts of high intensity exercise are slightly more effective than continuous high-intensity exercise for elevating serum BDNF. Additionally, 73% of the participants preferred the HIT protocol (P = 0.02). Therefore, we suggest that the HIT protocol might represent an effective and preferred intervention for elevating BDNF levels and potentially promoting brain health. Copyright © 2015 the American Physiological Society.

  6. Effects of exercise intensity and duration on nocturnal heart rate variability and sleep quality.

    PubMed

    Myllymäki, Tero; Rusko, Heikki; Syväoja, Heidi; Juuti, Tanja; Kinnunen, Marja-Liisa; Kyröläinen, Heikki

    2012-03-01

    Acute physical exercise may affect cardiac autonomic modulation hours or even days during the recovery phase. Although sleep is an essential recovery period, the information on nocturnal autonomic modulation indicated by heart rate variability (HRV) after different exercises is mostly lacking. Therefore, this study investigated the effects of exercise intensity and duration on nocturnal HR, HRV, HR, and HRV-based relaxation, as well as on actigraphic and subjective sleep quality. Fourteen healthy male subjects (age 36 ± 4 years, maximal oxygen uptake 49 ± 4 ml/kg/min) performed five different running exercises on separate occasions starting at 6 p.m. with HR guidance at home. The effect of intensity was studied with 30 min of exercises at intensities corresponding to HR level at 45% (easy), 60% (moderate) and 75% (vigorous) of their maximal oxygen uptake. The effect of duration was studied with 30, 60, and 90 min of moderate exercises. Increased exercise intensity elevated nocturnal HR compared to control day (p < 0.001), but it did not affect nocturnal HRV. Nocturnal HR was greater after the day with 90- than 30- or 60-min exercises (p < 0.01) or control day (p < 0.001). Nocturnal HRV was lower after the 90-min exercise day compared to control day (p < 0.01). Neither exercise intensity nor duration had any impact on actigraphic or subjective sleep quality. The results suggest that increased exercise intensity and/or duration cause delayed recovery of nocturnal cardiac autonomic modulation, although long exercise duration was needed to induce changes in nocturnal HRV. Increased exercise intensity or duration does not seem to disrupt sleep quality.

  7. Beam diagnostics at high-intensity storage rings

    NASA Astrophysics Data System (ADS)

    Plum, Mike

    1994-10-01

    Beam diagnostics at high-intensity facilities feature their own special set of problems and characteristics, issues peculiar to high-intensity storage rings include beam loss, beam halos, extraction efficiency, beam in the gap, clearing electrodes, and beam-profile measurement. The Los Alamos Proton Storage Ring (PSR) is a nice example of a high-intensity storage ring. I will discuss in some detail three diagnostic systems currently in use at the PSR: the beam-loss-monitor system, the electron-clearing system, and the beam-in-the-gap monitor. Much of our discussion is inspired by the problems we have encountered and the useful things we have learned while commissioning and developing the PSR. Another inspiration is our work on the next-generation neutron-spallation source, also known as the National Center for Neutron Research (NCNR).

  8. Pigment variations in Emiliania huxleyi (CCMP370) as a response to changes in light intensity or quality.

    PubMed

    Garrido, José L; Brunet, Christophe; Rodríguez, Francisco

    2016-12-01

    Many studies on photoacclimation examine the pigment responses to changes in light intensity, but variations in light climate in the aquatic environment are also related to changes in spectral composition. We have employed a high-performance liquid chromatography method with improved resolution towards chlorophyll c and fucoxanthin-related xanthophylls to examine the pigment composition of Emiliania huxleyi CCMP 370 under different light intensities and spectral qualities. To maintain its photosynthetic performance, E. huxleyi CCMP370 promotes drastic pigment changes that can be either the interconversion of pigments in pools with the same basic chromophoric structure (Fucoxanthin type or chlorophyll c type), or the ex novo synthesis (Diatoxanthin). These changes are linked either to variations in light quality (Fucoxanthin related xanthophylls) or in light intensity (chlorophyll c 3 /Monovinyl chlorophyll c 3 , Diadinoxanthin/Diatoxanthin, β,ɛ-carotene/ β,β-carotene). Fucoxanthin and 19'-hexanoyloxyfucoxanthin proportions were highly dependent on spectral conditions. Whereas Fucoxanthin dominated in green and red light, 19'-hexanoyloxyfucoxanthin prevailed under blue spectral conditions. Our results suggest that the huge pigment diversity enhanced the photoacclimative capacities of E. huxleyi to efficiently perform under changing light environments. The ubiquity and success in the global ocean as well as the capacity of E. huxleyi to form large surface blooms might be associated to the plasticity described here. © 2016 Society for Applied Microbiology and John Wiley & Sons Ltd.

  9. The effect of low and moderate intensity aerobic exercises on sleep quality in men older adults.

    PubMed

    Akbari Kamrani, Ahmad Ali; Shams, Amir; Shamsipour Dehkordi, Parvaneh; Mohajeri, Robabeh

    2014-03-01

    Sleep is an active and complex rhythmic state that may be affected by the aging process. The purpose of present research was to investigate the effect of low and moderate intensity aerobic exercises on sleep quality in older adults. The research method is quasi-experimental with pre-test and post-test design. The statistical sample included 45 volunteer elderly men with age range of 60-70 years-old that divided randomly in two experimental groups (aerobic exercise with low and moderate intensity) and one control group. In each group selected 15 older adults based on inclusion and exclusion criteria (such as, without sleep apnea, not smoking, and no taking hypnotic drugs). First, all subjects were evaluated by a doctor to confirm their physical and mental health. Also, the maximum heart rate (MaxHR) of subjects was obtained by subtracting one's age from 220. Furthermore, based on aerobic exercise type (40-50% MaxHR for low intensity group and 60-70% MaxHR for moderate intensity group) the target MaxHR was calculated for each subject. The exercise protocol consisted of 8 weeks aerobic exercises (2 sessions in per-week) based on Rockport one-mile walking/running test and the control group continued their daily activities. All subjects in per-test and post-test stages completed the Petersburg Sleep Quality Index (PSQI). In pre-test stage, results showed that there were no significant differences between control and experimental groups in sleep quality and its components (P>0.05). On the other hand, results in post-test stage showed that there were significant differences between control and experimental groups in these variables (P<0.05). Also, the Tukey Post Hoc showed that the moderate intensity group scores in total sleep quality and its components were better than other groups (P<0.05). Finally, the low intensity group scores in total sleep quality and its components were better than control group (P<0.05). Generally, the present research showed that the aerobic

  10. Salutary effects of high-intensity interval training in persons with elevated cardiovascular risk

    PubMed Central

    Fleg, Jerome L.

    2016-01-01

    Although moderate-intensity continuous training (MICT) has been the traditional model for aerobic exercise training for over four decades, a growing body of literature has demonstrated equal if not greater improvement in aerobic capacity and similar beneficial effects on body composition, glucose metabolism, blood pressure, and quality of life from high-intensity interval training (HIIT). An advantage of HIIT over MICT is the shorter time required to perform the same amount of energy expenditure. The current brief review summarizes the effects of HIIT on peak aerobic capacity and cardiovascular risk factors in healthy adults and those with various cardiovascular diseases, including coronary artery disease, chronic heart failure, and post heart transplantation. PMID:27635241

  11. Narrow Energy Spread Protons and Ions from High-Intensity, High-Contrast Laser Solid Target Interactions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dollar, Franklin; Matsuoka, Takeshi; McGuffey, Christopher

    2010-11-04

    Recent simulations show that an idealized, high intensity, short pulse laser can generate quasi-monoenergetic proton beams with energies over 100 MeV in an interaction with a thin film. However, most short pulse laser facilities with sufficient intensity have difficulty controlling the nanosecond and picosecond contrast necessary to realize such a regime. Experiments were performed to investigate proton and ion acceleration from a high contrast, short pulse laser by employing dual plasma mirrors along with a deformable mirror at the HERCULES laser facility at the Center for Ultrafast Optical Sciences, University of Michigan. Plasma mirrors were characterized, allowing a 50% throughputmore » with an intensity contrast increase of 105. The focal spot quality was also exceptional, showing a 1.1 micron full width at half maximum (FWHM) focal diameter. Experiments were done using temporally cleaned 30 TW, 32 fs pulses to achieve an intensity of up to 10{sup 21} Wcm{sup -2} on Si{sub 3}N{sub 4} and Mylar targets with thicknesses ranging 50 nm to 13 microns. Proton beams with energy spreads below 2 MeV were observed from all thicknesses, peaking with energies up to 10.3 MeV and an energy spread of 0.8 MeV. Similar narrow energy spreads were observed for oxygen, nitrogen, and carbon at the silicon nitride thickness of 50 nm with energies up to 24 MeV with an energy spread of 3 MeV, whereas the energy spread is greatly increased at a larger thickness. Maximum energies were confirmed with CR39 track detectors, while a Thomson ion spectrometer was used to gauge the monoenergetic nature of the beam.« less

  12. Improving the geomagnetic field modeling with a selection of high-quality archaeointensity data

    NASA Astrophysics Data System (ADS)

    Pavon-Carrasco, Francisco Javier; Gomez-Paccard, Miriam; Herve, Gwenael; Osete, Maria Luisa; Chauvin, Annick

    2014-05-01

    Geomagnetic field reconstructions for the last millennia are based on archeomagnetic data. However, the scatter of the archaeointensity data is very puzzling and clearly suggests that some of the intensity data might not be reliable. In this work we apply different selection criteria to the European and Western Asian archaeointensity data covering the last three millennia in order to investigate if the data selection affects geomagnetic field models results. Thanks to the recently developed archeomagnetic databases, new valuable information related to the methodology used to determine the archeointensity data is now available. We therefore used this information to rank the archaeointensity data in four quality categories depending on the methodology used during the laboratory treatment of the samples and on the number of specimens retained to calculate the mean intensities. Results show how the intensity geomagnetic field component given by the regional models hardly depends on the selected quality data used. When all the available data are used a different behavior of the geomagnetic field is observed in Western and Eastern Europe. However, when the regional model is obtained from a selection of high-quality intensity data the same features are observed at the European scale.

  13. Impact of Performance Obstacles on Intensive Care Nurses‘ Workload, Perceived Quality and Safety of Care, and Quality of Working Life

    PubMed Central

    Gurses, Ayse P; Carayon, Pascale; Wall, Melanie

    2009-01-01

    Objectives To study the impact of performance obstacles on intensive care nurses‘ workload, quality and safety of care, and quality of working life (QWL). Performance obstacles are factors that hinder nurses‘ capacity to perform their job and that are closely associated with their immediate work system. Data Sources/Study Setting Data were collected from 265 nurses in 17 intensive care units (ICUs) between February and August 2004 via a structured questionnaire, yielding a response rate of 80 percent. Study Design A cross-sectional study design was used. Data were analyzed by correlation analyses and structural equation modeling. Principal Findings Performance obstacles were found to affect perceived quality and safety of care and QWL of ICU nurses. Workload mediated the impact of performance obstacles with the exception of equipment-related issues on perceived quality and safety of care as well as QWL. Conclusions Performance obstacles in ICUs are a major determinant of nursing workload, perceived quality and safety of care, and QWL. In general, performance obstacles increase nursing workload, which in turn negatively affect perceived quality and safety of care and QWL. Redesigning the ICU work system to reduce performance obstacles may improve nurses‘ work. PMID:19207589

  14. Light-intensity modulator withstands high heat fluxes

    NASA Technical Reports Server (NTRS)

    Maples, H. G.; Strass, H. K.

    1966-01-01

    Mechanism modulates and controls the intensity of luminous radiation in light beams associated with high-intensity heat flux. This modulator incorporates two fluid-cooled, externally grooved, contracting metal cylinders which when rotated about their longitudinal axes present a circular aperture of varying size depending on the degree of rotation.

  15. High optical quality GaN nanopillar arrays

    NASA Astrophysics Data System (ADS)

    Wang, Y. D.; Chua, S. J.; Tripathy, S.; Sander, M. S.; Chen, P.; Fonstad, C. G.

    2005-02-01

    GaN nanopillar arrays have been fabricated by inductively coupled plasma etching of GaN films using anodic aluminum oxide film as an etch mask. The average diameter and length of these pillars are 60-65nm and 350-400nm, respectively. Ultraviolet microphotoluminescence measurements indicate high photoluminescence intensity and stress relaxation in these GaN nanopillars as compared to the starting epitaxial GaN films. Evidence of good crystalline quality is also observed by micro-Raman measurements, wherein a redshift of the E2high mode from GaN nanopillars suggests partial relaxation of the compressive strain. In addition, breakdown of the polarization selection rules led to the appearance of symmetry-forbidden and quasipolar modes.

  16. MO-AB-210-03: Workshop [Advancements in high intensity focused ultrasound

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu, Z.

    The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrationsmore » with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant

  17. Pregabalin beneficial effects on sleep quality or health-related quality of life are poorly correlated with reduction on pain intensity after an 8-week treatment course.

    PubMed

    Perez-Lloret, Santiago; Rojas, Gloria Meza; Menoni, Maria Celia; Ruiz, Gabriela; Velásquez, Carolina; Rodriguez, Hernán; Rey, María Verónica; Cardinali, And Daniel P

    2012-01-01

    Pregabalin (PGB) has been shown to improve sleep quality and health-related quality of life (HRQoL) as well as pain intensity in patients with neuropathic pain. The objective of the study was to explore the magnitude of the correlations between changes in pain intensity, sleep quality, and HRQoL after PGB treatment. One hundred thirty-eight patients with neuropathic pain of any origin and without an adequate response to analgesics received an 8-week treatment course of PGB in an open-label fashion. Pain intensity, sleep quality, and HRQoL outcomes were evaluated at baseline and at week 8 by means of an 11-point (0-10) numerical rating scale (NRS), the Pittsburgh Sleep Quality Index (PSQI), and the EuroQol health-state visuoanalogic scale (EQ-5D VAS) score, respectively. At week 8, mean PGB dose was 166.7 ± 7.8 mg/d. Pain intensity NRS score, PSQI total score, and EQ-5D VAS score were improved by 66.5% ± 1.9%, 40.0% ± 3.6%, and 26.4% ± 4.7% (all P < 0.01), respectively. Correlations between percent change from baseline in pain NRS score and PSQI total score or EQ-5D VAS scores were r = 0.36 (P < 0.01, R = 0.11) and r = -0.20 (P < 0.02, R = 0.05), respectively. A multivariate logistic regression analysis disclosed that PSQI score change below the median (ie, a better outcome) was related to higher EQ-5D VAS score change (odds ratio, 2.15; 95% confidence interval, 1.09-4.25), whereas pain intensity NRS score change below the median was not (odds ratio, 1.58; 95% confidence interval,0.78-3.23). In our study, PGB-related improvements in sleep quality and HRQoL were marginally related to reductions in pain intensity in patients with neuropathic pain. Improvement in sleep quality was a significant predictor of better HRQoL, whereas pain intensity reduction was not.

  18. Efficacy of high intensity atorvastatin versus moderate intensity atorvastatin for acute coronary syndrome patients with diabetes mellitus.

    PubMed

    Liu, Zhi; Xu, Yueqiao; Hao, Hengjian; Yin, Chunlin; Xu, Ji; Li, Jing; Wang, Yanling; Xu, Dong

    2016-11-01

    To investigate whether more benefits can be achieved through high intensity atorvastatin compared with moderate intensity atorvastatin in acute coronary syndrome (ACS) patients with diabetes mellitus (DM). This was a randomized controlled trail. Total 591 ACS patients with DM who underwent percutaneous coronary intervention were enrolled, 297 in high intensity atorvastatin group (40mg/day) and 294 in moderate intensity atorvastatin group (20mg/day). The primary end point was one-year incidence of major adverse cardiovascular events (MACE, including cardiovascular death, spontaneous myocardial infarction, unplanned revascularization). Cox proportional hazard regression models were used to analyze the association between clinical endpoints and atorvastatin treatment. At the end of one-year, low-density lipoprotein cholesterol level was lower in high intensity group than in moderate group (1.6±0.6 vs 1.8±0.6, p=0.041). MACE in high intensity group decreased 44.5% than moderate group (8.4% vs. 14.6%, p=0.018). The adjusted hazard ratio (HR) for MACE in patients with atorvastatin 40mg/d was lower compared to patients with atorvastatin 20mg/d (HR [95% CI] 0.61 [0.36 to 0.91], p=0.026). The rates of adverse events were no significantly different between the two groups. For ACS patients with DM, high intensity atorvastatin induced better long-term outcomes compared with moderate intensity. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Quality assurance of intensity-modulated radiation therapy.

    PubMed

    Palta, Jatinder R; Liu, Chihray; Li, Jonathan G

    2008-01-01

    The current paradigm for the quality assurance (QA) program for intensity-modulated radiation therapy (IMRT) includes QA of the treatment planning system, QA of the delivery system, and patient-specific QA. Although the IMRT treatment planning and delivery system is the same as for conventional three-dimensional conformal radiation therapy, it has more parameters to coordinate and verify. Because of complex beam intensity modulation, each IMRT field often includes many small irregular off-axis fields, resulting in isodose distributions for each IMRT plan that are more conformal than those from conventional treatment plans. Therefore, these features impose a new and more stringent set of QA requirements for IMRT planning and delivery. The generic test procedures to validate dose calculation and delivery accuracy for both treatment planning and IMRT delivery have to be customized for each type of IMRT planning and delivery strategy. The rationale for such an approach is that the overall accuracy of IMRT delivery is incumbent on the piecewise uncertainties in both the planning and delivery processes. The end user must have well-defined evaluation criteria for each element of the planning and delivery process. Such information can potentially be used to determine a priori the accuracy of IMRT planning and delivery.

  20. Disparities in Perinatal Quality Outcomes for Very Low Birth Weight Infants in Neonatal Intensive Care

    PubMed Central

    Lake, Eileen T; Staiger, Douglas; Horbar, Jeffrey; Kenny, Michael J; Patrick, Thelma; Rogowski, Jeannette A

    2015-01-01

    Objective To determine if hospital-level disparities in very low birth weight (VLBW) infant outcomes are explained by poorer hospital nursing characteristics. Data Sources Nurse survey and VLBW infant registry data. Study Design Retrospective study of 8,252 VLBW infants in 98 Vermont Oxford Network hospital neonatal intensive care units (NICUs) nationally. NICUs were classified into three groups based on their percent of infants of black race. Two nurse-sensitive perinatal quality standards were studied: nosocomial infection and breast milk. Data Collection Primary nurse survey (N = 5,773, 77 percent response rate). Principal Findings VLBW infants born in high-black concentration hospitals had higher rates of infection and discharge without breast milk than VLBW infants born in low-black concentration hospitals. Nurse understaffing was higher and practice environments were worse in high-black as compared to low-black hospitals. NICU nursing features accounted for one-third to one-half of the hospital-level health disparities. Conclusions Poorer nursing characteristics contribute to disparities in VLBW infant outcomes in two nurse-sensitive perinatal quality standards. Improvements in nursing have potential to improve the quality of care for seven out of ten black VLBW infants who are born in high-black hospitals in this country. PMID:25250882

  1. High Intensity Mirror-Free Nanosecond Ytterbium Fiber Laser System in Master Oscillator Power Amplification

    NASA Astrophysics Data System (ADS)

    Chun-Lin, Louis Chang

    Rare-earth-doped fiber lasers and amplifiers are relatively easy to efficiently produce a stable and high quality laser beam in a compact, robust, and alignment-free configuration. Recently, high power fiber laser systems have facilitated wide spread applications in academics, industries, and militaries in replacement of bulk solid-state laser systems. The master oscillator power amplifier (MOPA) composed of a highly-controlled seed, high-gain preamplifiers, and high-efficiency power amplifiers are typically utilized to scale up the pulse energy, peak power, or average power. Furthermore, a direct-current-modulated nanosecond diode laser in single transverse mode can simply provide a compact and highly-controlled seed to result in the flexible output parameters, such as repetition rate, pulse duration, and even temporal pulse shape. However, when scaling up the peak power for high intensity applications, such a versatile diode-seeded nanosecond MOPA laser system using rare-earth-doped fibers is unable to completely save its own advantages compared to bulk laser systems. Without a strong seeding among the amplifiers, the guided amplified spontaneous amplification is easy to become dominant during the amplification, leading to the harmful self-lasing or pulsing effects, and the difficulty of the quantitative numerical comparison. In this dissertation, we study a high-efficiency and intense nanosecond ytterbium fiber MOPA system with good beam quality and stability for high intensity applications. The all-PM-fiber structure is achieved with the output extinction ratio of >12 dB by optimizing the interconnection of high power optical fibers. The diode-seeded MOPA configuration without parasitic stimulated amplification (PAS) is implemented using the double-pass scheme to extract energy efficiently for scaling peak power. The broadband PAS was studied experimentally, which matches well with our numerical simulation. The 1064-nm nanosecond seed was a direct

  2. Proton shock acceleration using a high contrast high intensity laser

    NASA Astrophysics Data System (ADS)

    Gauthier, Maxence; Roedel, Christian; Kim, Jongjin; Aurand, Bastian; Curry, Chandra; Goede, Sebastian; Propp, Adrienne; Goyon, Clement; Pak, Art; Kerr, Shaun; Ramakrishna, Bhuvanesh; Ruby, John; William, Jackson; Glenzer, Siegfried

    2015-11-01

    Laser-driven proton acceleration is a field of intense research due to the interesting characteristics of this novel particle source including high brightness, high maximum energy, high laminarity, and short duration. Although the ion beam characteristics are promising for many future applications, such as in the medical field or hybrid accelerators, the ion beam generated using TNSA, the acceleration mechanism commonly achieved, still need to be significantly improved. Several new alternative mechanisms have been proposed such as collisionless shock acceleration (CSA) in order to produce a mono-energetic ion beam favorable for those applications. We report the first results of an experiment performed with the TITAN laser system (JLF, LLNL) dedicated to the study of CSA using a high intensity (5x1019W/cm2) high contrast ps laser pulse focused on 55 μm thick CH and CD targets. We show that the proton spectrum generated during the interaction exhibits high-energy mono-energetic features along the laser axis, characteristic of a shock mechanism.

  3. Performance of high intensity fed-batch mammalian cell cultures in disposable bioreactor systems.

    PubMed

    Smelko, John Paul; Wiltberger, Kelly Rae; Hickman, Eric Francis; Morris, Beverly Janey; Blackburn, Tobias James; Ryll, Thomas

    2011-01-01

    The adoption of disposable bioreactor technology as an alternate to traditional nondisposable technology is gaining momentum in the biotechnology industry. Evaluation of current disposable bioreactors systems to sustain high intensity fed-batch mammalian cell culture processes needs to be explored. In this study, an assessment was performed comparing single-use bioreactors (SUBs) systems of 50-, 250-, and 1,000-L operating scales with traditional stainless steel (SS) and glass vessels using four distinct mammalian cell culture processes. This comparison focuses on expansion and production stage performance. The SUB performance was evaluated based on three main areas: operability, process scalability, and process performance. The process performance and operability aspects were assessed over time and product quality performance was compared at the day of harvest. Expansion stage results showed disposable bioreactors mirror traditional bioreactors in terms of cellular growth and metabolism. Set-up and disposal times were dramatically reduced using the SUB systems when compared with traditional systems. Production stage runs for both Chinese hamster ovary and NS0 cell lines in the SUB system were able to model SS bioreactors runs at 100-, 200-, 2,000-, and 15,000-L scales. A single 1,000-L SUB run applying a high intensity fed-batch process was able to generate 7.5 kg of antibody with comparable product quality. Copyright © 2011 American Institute of Chemical Engineers (AIChE).

  4. Whole-Body High-Intensity Interval Training Induce Similar Cardiorespiratory Adaptations Compared With Traditional High-Intensity Interval Training and Moderate-Intensity Continuous Training in Healthy Men.

    PubMed

    Schaun, Gustavo Z; Pinto, Stephanie S; Silva, Mariana R; Dolinski, Davi B; Alberton, Cristine L

    2018-05-07

    Schaun, GZ, Pinto, SS, Silva, MR, Dolinski, DB, and Alberton, CL. Sixteen weeks of whole-body high-intensity interval training induce similar cardiorespiratory responses compared with traditional high-intensity interval training and moderate-intensity continuous training in healthy men. J Strength Cond Res XX(X): 000-000, 2018-Low-volume high-intensity interval training (HIIT) protocols that use the body weight as resistance could be an interesting and inexpensive alternative to traditional ergometer-based high-intensity interval training (HIIT-T) and moderate-intensity continuous training (MICT). Therefore, our aim was to compare the effects of 16 weeks of whole-body HIIT (HIIT-WB), HIIT-T, and MICT on maximal oxygen uptake (V[Combining Dot Above]O2max), second ventilatory threshold (VT2), and running economy (RE) outcomes. Fifty-five healthy men (23.7 ± 0.7 years, 1.79 ± 0.01 m, 78.5 ± 1.7 kg) were randomized into 3 training groups (HIIT-T = 17; HIIT-WB = 19; MICT = 19) for 16 weeks (3× per week). The HIIT-T group performed eight 20-second bouts at 130% of the velocity associated to V[Combining Dot Above]O2max (vV[Combining Dot Above]O2max) interspersed by 10-second passive recovery on a treadmill, whereas HIIT-WB group performed the same protocol but used calisthenics exercises at an all-out intensity instead of treadmill running. Finally, MICT group exercised for 30 minutes at 90-95% of the heart rate (HR) associated to VT2. After the intervention, all groups improved V[Combining Dot Above]O2max, vV[Combining Dot Above]O2max, time to exhaustion (Tmax), VT2, velocity associated with VT2 (vVT2), and time to reach VT2 (tVT2) significantly (p < 0.05). Moreover, Tmax, vVT2, and tVT2 were greater after HIIT-T compared with HIIT-WB (p < 0.05), whereas oxygen uptake increased and HR decreased during the RE test in all groups (p < 0.05). Our results demonstrate that HIIT-WB can be as effective as traditional HIIT while also being time-efficient compared with MICT to

  5. High quality digital holographic reconstruction on analog film

    NASA Astrophysics Data System (ADS)

    Nelsen, B.; Hartmann, P.

    2017-05-01

    High quality real-time digital holographic reconstruction, i.e. at 30 Hz frame rates, has been at the forefront of research and has been hailed as the holy grail of display systems. While these efforts have produced a fascinating array of computer algorithms and technology, many applications of reconstructing high quality digital holograms do not require such high frame rates. In fact, applications such as 3D holographic lithography even require a stationary mask. Typical devices used for digital hologram reconstruction are based on spatial-light-modulator technology and this technology is great for reconstructing arbitrary holograms on the fly; however, it lacks the high spatial resolution achievable by its analog counterpart, holographic film. Analog holographic film is therefore the method of choice for reconstructing highquality static holograms. The challenge lies in taking a static, high-quality digitally calculated hologram and effectively writing it to holographic film. We have developed a theoretical system based on a tunable phase plate, an intensity adjustable high-coherence laser and a slip-stick based piezo rotation stage to effectively produce a digitally calculated hologram on analog film. The configuration reproduces the individual components, both the amplitude and phase, of the hologram in the Fourier domain. These Fourier components are then individually written on the holographic film after interfering with a reference beam. The system is analogous to writing angularly multiplexed plane waves with individual component phase control.

  6. Aggregating land use quantity and intensity to link water quality in upper catchment of Miyun Reservoir

    NASA Astrophysics Data System (ADS)

    Xu, E.

    2015-12-01

    Land use is closely related to hydrological and biochemical processes influencing the water quality. Quantifying relationship between both of them can help effectively manage land use to improve water quality. Previous studies majorly utilized land use quantity as an indicator to link water quality parameters, which lacked an insight to the influence of land use intensity. Taking upper catchment of Miyun Reservoir as a case study, we proposed a method of aggregating land use quantity and intensity to build a new land use indicator and investigated its explanation empower on water quality. Six nutrient concentrations from 52 sub-watersheds covering the whole catchment were used to characterize spatial distributions of water eutrophication. Based on spatial techniques and empirical conversion coefficients, combined remote sensing with socio-economic statistical data, land use intensity was measured and mapped visually. Then the new land use indicator was calculated and linked to nutrient concentrations by Pearson correlation coefficients. Results demonstrated that our new land use indicator incorporating intensity information can quantify the potential different nutrients exporting abilities from land uses. Comparing to traditional indicators only characterized by land use quantity, most Pearson correlation coefficients between new indicator and water nutrient concentrations increased. New information enhanced the explanatory power of land use on water nutrient concentrations. Then it can help better understand the impact of land use on water quality and guide land use management for supporting decision making.

  7. Nurse-perceived quality of care in intensive care units and associations with work environment characteristics: a multicentre survey study.

    PubMed

    Stalpers, Dewi; Van Der Linden, Dimitri; Kaljouw, Marian J; Schuurmans, Marieke J

    2017-06-01

    To examine nurse-perceived quality of care, controlling for overall job satisfaction among critical care nurses and to explore associations with work environment characteristics. Nurse-perceived quality of care and job satisfaction have been positively linked to quality outcomes for nurses and patients. Much evidence exists on factors contributing to job satisfaction. Understanding specific factors that affect nurse-perceived quality potentially enables for improvements of nursing care quality. A multicentre survey study was conducted in three Dutch intensive care units. The Dutch version of the Essentials of Magnetism II questionnaire was used; including the single-item indicators: (i) nurse-perceived quality of care; (ii) overall job satisfaction; and (iii) 58 statements on work environments. Data were collected between October 2013 - June 2014. The majority of 123 responding nurses (response rate 45%) were more than satisfied with quality of care (55%) and with their job (66%). No associations were found with nurse characteristics, besides differences in job satisfaction between the units. After controlling for job satisfaction, nurse-perceived quality was positively associated with the work environment characteristics: adequacy of staffing, patient-centeredness, competent peers and support for education. Patient-centeredness and autonomy were the most important predictors for overall job satisfaction. Factors that contribute to nurse-perceived quality of care in intensive care units, independent from the effects of overall job satisfaction, were identified. Hereby, offering opportunities to maximize high quality of care to critically ill patients. Research in a larger sample is needed to confirm our findings. © 2016 John Wiley & Sons Ltd.

  8. Nutrition therapy with high intensity interval training to improve prostate cancer-related fatigue in men on androgen deprivation therapy: a study protocol.

    PubMed

    Baguley, Brenton J; Skinner, Tina L; Leveritt, Michael D; Wright, Olivia R L

    2017-01-03

    Cancer-related fatigue is one of the most prevalent, prolonged and distressing side effects of prostate cancer treatment with androgen deprivation therapy. Preliminary evidence suggests natural therapies such as nutrition therapy and structured exercise prescription can reduce symptoms of cancer-related fatigue. Men appear to change their habitual dietary patterns after prostate cancer diagnosis, yet prostate-specific dietary guidelines provide limited support for managing adverse side effects of treatment. The exercise literature has shown high intensity interval training can improve various aspects of health that are typically impaired with androgen deprivation therapy; however exercise at this intensity is yet to be conducted in men with prostate cancer. The purpose of this study is to examine the effects of nutrition therapy beyond the current healthy eating guidelines with high intensity interval training for managing cancer-related fatigue in men with prostate cancer treated with androgen deprivation therapy. This is a two-arm randomized control trial of 116 men with prostate cancer and survivors treated with androgen deprivation therapy. Participants will be randomized to either the intervention group i.e. nutrition therapy and high intensity interval training, or usual care. The intervention group will receive 20 weeks of individualized nutrition therapy from an Accredited Practising Dietitian, and high intensity interval training (from weeks 12-20 of the intervention) from an Accredited Exercise Physiologist. The usual care group will maintain their standard treatment regimen over the 20 weeks. Both groups will undertake primary and secondary outcome testing at baseline, week 8, 12, and 20; testing includes questionnaires of fatigue and quality of life, objective measures of body composition, muscular strength, cardiorespiratory fitness, biomarkers for disease progression, as well as dietary analysis. The primary outcomes for this trial are measures of

  9. Underutilization of high-intensity statin therapy after hospitalization for coronary heart disease.

    PubMed

    Rosenson, Robert S; Kent, Shia T; Brown, Todd M; Farkouh, Michael E; Levitan, Emily B; Yun, Huifeng; Sharma, Pradeep; Safford, Monika M; Kilgore, Meredith; Muntner, Paul; Bittner, Vera

    2015-01-27

    National guidelines recommend use of high-intensity statins after hospitalization for coronary heart disease (CHD) events. This study sought to estimate the proportion of Medicare beneficiaries filling prescriptions for high-intensity statins after hospital discharge for a CHD event and to analyze whether statin intensity before hospitalization is associated with statin intensity after discharge. We conducted a retrospective cohort study using a 5% random sample of Medicare beneficiaries between 65 and 74 years old. Beneficiaries were included in the analysis if they filled a statin prescription after a CHD event (myocardial infarction or coronary revascularization) in 2007, 2008, or 2009. High-intensity statins included atorvastatin 40 to 80 mg, rosuvastatin 20 to 40 mg, and simvastatin 80 mg. Among 8,762 Medicare beneficiaries filling a statin prescription after a CHD event, 27% of first post-discharge fills were for a high-intensity statin. The percent filling a high-intensity statin post-discharge was 23.1%, 9.4%, and 80.7%, for beneficiaries not taking statins pre-hospitalization, taking low/moderate-intensity statins, and taking high-intensity statins before their CHD event, respectively. Compared with beneficiaries not on statin therapy pre-hospitalization, multivariable adjusted risk ratios for filling a high-intensity statin were 4.01 (3.58-4.49) and 0.45 (0.40-0.52) for participants taking high-intensity and low/moderate-intensity statins before their CHD event, respectively. Only 11.5% of beneficiaries whose first post-discharge statin fill was for a low/moderate-intensity statin filled a high-intensity statin within 365 days of discharge. The majority of Medicare beneficiaries do not fill high-intensity statins after hospitalization for CHD. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  10. Quality Improvement Initiative for Family-Centered Care in the Neonatal Intensive Care Unit of a Tertiary Hospital in South Africa.

    PubMed

    Maree, Carin; Kekana, Poppy; van der Walt, Christa; Yazbek, Mariatha; Leech, Ronell

    The introduction of family-centered care in the neonatal intensive care unit was identified as a high priority to facilitate bonding and attachment with potential positive outcomes for the parents and infants. The aim of the study was, therefore, to develop and implement a quality improvement initiative to foster family-centered care in a tertiary neonatal intensive care unit from birth onward. A pretest posttest intervention design was used using mixed methods over 3 phases to determine the perceived level of family-centered care according to healthcare professionals and parents using self-administered questionnaires; to develop and implement a quality improvement initiative to enhance family-centered care in a neonatal intensive care unit using a nominal group technique, followed by the quality improvement process; and to evaluate the outcomes of the initiative by repeating the self-administered questionnaires to parents and staff. Various activities were introduced as part of the initiative such as early breastfeeding, early introduction of parents to their infant, open visitation policy, and involvement in caring activities. The perceived level of care according to staff and parents increased. It is expected to enhance bonding and attachment between the infants and their parents, with consequential long-term positive outcomes.

  11. Moderate-to-High Intensity Physical Exercise in Patients with Alzheimer's Disease: A Randomized Controlled Trial.

    PubMed

    Hoffmann, Kristine; Sobol, Nanna A; Frederiksen, Kristian S; Beyer, Nina; Vogel, Asmus; Vestergaard, Karsten; Brændgaard, Hans; Gottrup, Hanne; Lolk, Annette; Wermuth, Lene; Jacobsen, Søren; Laugesen, Lars P; Gergelyffy, Robert G; Høgh, Peter; Bjerregaard, Eva; Andersen, Birgitte B; Siersma, Volkert; Johannsen, Peter; Cotman, Carl W; Waldemar, Gunhild; Hasselbalch, Steen G

    2016-01-01

    Studies of physical exercise in patients with Alzheimer's disease (AD) are few and results have been inconsistent. To assess the effects of a moderate-to-high intensity aerobic exercise program in patients with mild AD. In a randomized controlled trial, we recruited 200 patients with mild AD to a supervised exercise group (60-min sessions three times a week for 16 weeks) or to a control group. Primary outcome was changed from baseline in cognitive performance estimated by Symbol Digit Modalities Test (SDMT) in the intention-to-treat (ITT) group. Secondary outcomes included changes in quality of life, ability to perform activities of daily living, and in neuropsychiatric and depressive symptoms. The ITT analysis showed no significant differences between intervention and control groups in change from baseline of SDMT, other cognitive tests, quality of life, or activities of daily living. The change from baseline in Neuropsychiatric Inventory differed significantly in favor of the intervention group (mean: -3.5, 95% confidence interval (CI) -5.8 to -1.3, p = 0.002). In subjects who adhered to the protocol, we found a significant effect on change from baseline in SDMT as compared with the control group (mean: 4.2, 95% CI 0.5 to 7.9, p = 0.028), suggesting a dose-response relationship between exercise and cognition. This is the first randomized controlled trial with supervised moderate-to-high intensity exercise in patients with mild AD. Exercise reduced neuropsychiatric symptoms in patients with mild AD, with possible additional benefits of preserved cognition in a subgroup of patients exercising with high attendance and intensity.

  12. Creating a Highly Reliable Neonatal Intensive Care Unit Through Safer Systems of Care.

    PubMed

    Panagos, Patoula G; Pearlman, Stephen A

    2017-09-01

    Neonates requiring intensive care are at high risk for medical errors due to their unique characteristics and high acuity. Designing a safer work environment begins with safe processes. Creating a culture of safety demands the involvement of all organizational levels and an interdisciplinary approach. Adverse events can result from suboptimal communication and lack of a shared mental model. This chapter describes tools to promote better patient safety in the NICU through monitoring adverse events, improving communication and using information technology. Unplanned extubation is an example of a neonatal safety concern that can be reduced by employing quality improvement methodology. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. The compressed average image intensity metric for stereoscopic video quality assessment

    NASA Astrophysics Data System (ADS)

    Wilczewski, Grzegorz

    2016-09-01

    The following article depicts insights towards design, creation and testing of a genuine metric designed for a 3DTV video quality evaluation. The Compressed Average Image Intensity (CAII) mechanism is based upon stereoscopic video content analysis, setting its core feature and functionality to serve as a versatile tool for an effective 3DTV service quality assessment. Being an objective type of quality metric it may be utilized as a reliable source of information about the actual performance of a given 3DTV system, under strict providers evaluation. Concerning testing and the overall performance analysis of the CAII metric, the following paper presents comprehensive study of results gathered across several testing routines among selected set of samples of stereoscopic video content. As a result, the designed method for stereoscopic video quality evaluation is investigated across the range of synthetic visual impairments injected into the original video stream.

  14. Light-intensity and high-intensity interval training improve cardiometabolic health in rats.

    PubMed

    Batacan, Romeo B; Duncan, Mitch J; Dalbo, Vincent J; Connolly, Kylie J; Fenning, Andrew S

    2016-09-01

    Physical activity has the potential to reduce cardiometabolic risk factors but evaluation of different intensities of physical activity and the mechanisms behind their health effects still need to be fully established. This study examined the effects of sedentary behaviour, light-intensity training, and high-intensity interval training on biometric indices, glucose and lipid metabolism, inflammatory and oxidative stress markers, and vascular and cardiac function in adult rats. Rats (12 weeks old) were randomly assigned to 1 of 4 groups: control (CTL; no exercise), sedentary (SED; no exercise and housed in small cages to reduce activity), light-intensity trained (LIT; four 30-min exercise bouts/day at 8 m/min separated by 2-h rest period, 5 days/week), and high-intensity interval trained (HIIT, four 2.5-min work bouts/day at 50 m/min separated by 3-min rest periods, 5 days/week). After 12 weeks of intervention, SED had greater visceral fat accumulation (p < 0.01) and slower cardiac conduction (p = 0.04) compared with the CTL group. LIT and HIIT demonstrated beneficial changes in body weight, visceral and epididymal fat weight, glucose regulation, low-density lipoprotein cholesterol, total cholesterol, and mesenteric vessel contractile response compared with the CTL group (p < 0.05). LIT had significant improvements in insulin sensitivity and cardiac conduction compared with the CTL and SED groups whilst HIIT had significant improvements in systolic blood pressure and endothelium-independent vasodilation to aorta and mesenteric artery compared with the CTL group (p < 0.05). LIT and HIIT induce health benefits by improving traditional cardiometabolic risk factors. LIT improves cardiac health while HIIT promotes improvements in vascular health.

  15. Untreated runoff quality from roof and road surfaces in a low intensity rainfall climate.

    PubMed

    Charters, Frances J; Cochrane, Thomas A; O'Sullivan, Aisling D

    2016-04-15

    Sediment and heavy metals in stormwater runoff are key pollutants of urban waterways, and their presence in stormwater is driven by climatic factors such as rainfall intensity. This study describes the total suspended solids (TSS) and heavy metal concentrations found in runoff from four different urban surfaces within a residential/institutional catchment, in a climate where rainfall is typically of low intensity (<5.1mm·h(-1)). The results were compared to untreated runoff quality from a compilation of international studies. The road runoff had the highest TSS concentrations, while copper and galvanized roof runoff had the highest copper and zinc concentrations, respectively. Pollutant concentrations were found to be significantly different between surfaces; quantification and prediction of pollutant contributions from urban surfaces should thus take account of the different surface materials, instead of being aggregated into more generalized categories such as land use. The TSS and heavy metal concentrations were found to be at the low to medium end of ranges observed internationally, except for total copper and zinc concentrations generated by dissolution of copper and galvanized roofing material respectively; these concentrations were at least as high as those reported internationally. TSS wash-off from the roofs was seen to be a source-limited process, where all available TSS is washed off during the rain event despite the low intensity rainfall, whereas both road TSS and heavy metals wash-off from roof and road surfaces appeared to all be transport-limited and therefore some carryover of pollutants occurs between rain events. A first flush effect was seen from most surfaces for TSS, but not for heavy metals. This study demonstrates that in low intensity rainfall climates, quantification of untreated runoff quality from key individual surface types in a catchment are needed to enable development of targeted and appropriately sized stormwater treatment systems

  16. Quality of MR thermometry during palliative MR-guided high-intensity focused ultrasound (MR-HIFU) treatment of bone metastases.

    PubMed

    Lam, Mie K; Huisman, Merel; Nijenhuis, Robbert J; van den Bosch, Maurice Aaj; Viergever, Max A; Moonen, Chrit Tw; Bartels, Lambertus W

    2015-01-01

    Magnetic resonance (MR)-guided high-intensity focused ultrasound has emerged as a clinical option for palliative treatment of painful bone metastases, with MR thermometry (MRT) used for treatment monitoring. In this study, the general image quality of the MRT was assessed in terms of signal-to-noise ratio (SNR) and apparent temperature variation. Also, MRT artifacts were scored for their occurrence and hampering of the treatment monitoring. Analyses were performed on 224 MRT datasets retrieved from 13 treatments. The SNR was measured per voxel over time in magnitude images, in the target lesion and surrounding muscle, and was averaged per treatment. The standard deviation over time of the measured temperature per voxel in MRT images, in the muscle outside the heated region, was defined as the apparent temperature variation and was averaged per treatment. The scored MRT artifacts originated from the following sources: respiratory and non-respiratory time-varying field inhomogeneities, arterial ghosting, and patient motion by muscle contraction and by gross body movement. Distinction was made between lesion type, location, and procedural sedation and analgesic (PSA). The average SNR was highest in and around osteolytic lesions (21 in lesions, 27 in surrounding muscle, n = 4) and lowest in the upper body (9 in lesions, 16 in surrounding muscle, n = 4). The average apparent temperature variation was lowest in osteolytic lesions (1.2°C, n = 4) and the highest in the upper body (1.7°C, n = 4). Respiratory time-varying field inhomogeneity MRT artifacts occurred in 85% of the datasets and hampered treatment monitoring in 81%. Non-respiratory time-varying field inhomogeneities and arterial ghosting MRT artifacts were most frequent (94% and 95%) but occurred only locally. Patient motion artifacts were highly variable and occurred less in treatments of osteolytic lesions and using propofol and esketamine as PSA. In this study, the general image quality of

  17. High intensity interval training versus moderate intensity continuous training on exercise capacity and quality of life in patients with heart failure with reduced ejection fraction: A systematic review and meta-analysis.

    PubMed

    Gomes Neto, Mansueto; Durães, André Rodrigues; Conceição, Lino Sergio Rocha; Saquetto, Micheli Bernardone; Ellingsen, Øyvind; Carvalho, Vitor Oliveira

    2018-06-15

    The aim of this study was to investigate the effects of high intensity interval training (HIIT) versus moderate intensity continuous training (MICT) in heart failure patients with reduced ejection fraction (HFrEF). Despite the well-known positive effects of exercise in heart failure patients, the best mode of exercise is still under discussion. We searched Pubmed/MEDLINE, Cochrane Central Register of Controlled Trials, PEDro data base, and SciELO (from the earliest date available to October 2017) for randomized controlled trials that evaluated the effects of HIIT versus MICT in HFrEF patients. Weighted mean differences (WMD) with 95% confidence interval (CI) were calculated, and heterogeneity was assessed using the I 2 test. 13 studies met the study criteria, including 411 patients. Compared to MICT, HIIT resulted in improvement in Peak VO 2 WMD (1.35 mL·kg -1 ·min -1 95% CI: 0.03 to 2.64 N = 411). HIIT resulted in no difference in VE/VCO 2 slope WMD (-1.21 95% CI: -3.0 to 0.58 N = 135), and quality of life measured by Minnesota Living with Heart Failure questionnaire WMD (1.19 95% CI: -5.81 to 8.19 N = 79). Sub-group analyses comparing studies with and without isocaloric exercise training protocol also showed a nonsignificant difference in peak VO 2 for participants in the HIIT group compared with MICT group. HIIT improves peak VO 2 and should be considered as a component of care of HFrEF patients. However, its superiority versus MICT disappears when isocaloric protocols are compared. An important caveat is uncertainty and variation of actual training intensities compared to program targets. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Exercise training modalities in chronic heart failure: does high intensity aerobic interval training make the difference?

    PubMed

    Giallauria, Francesco; Smart, Neil Andrew; Cittadini, Antonio; Vigorito, Carlo

    2016-10-14

    Exercise training (ET) is strongly recommended in patients with chronic heart failure (CHF). Moderate-intensity aerobic continuous ET is the best established training modality in CHF patients. In the last decade, however, high-intensity interval exercise training (HIIT) has aroused considerable interest in cardiac rehabilitation community. Basically, HIIT consists of repeated bouts of high-intensity exercise alternated with recovery periods. In CHF patients, HIIT exerts larger improvements in exercise capacity compared to moderate-continuous ET. These results are intriguing, mostly considering that better functional capacity translates into an improvement of symptoms and quality of life. Notably, HIIT did not reveal major safety issues; although CHF patients should be clinically stable, have had recent exposure to at least regular moderate-intensity exercise, and appropriate supervision and monitoring during and after the exercise session are mandatory. The impact of HIIT on cardiac dimensions and function and on endothelial function remains uncertain. HIIT should not replace other training modalities in heart failure but should rather complement them. Combining and tailoring different ET modalities according to each patient's baseline clinical characteristics (i.e. exercise capacity, personal needs, preferences and goals) seem the most astute approach to exercise prescription.

  19. A 3-week multimodal intervention involving high-intensity interval training in female cancer survivors: a randomized controlled trial.

    PubMed

    Schmitt, Joachim; Lindner, Nathalie; Reuss-Borst, Monika; Holmberg, Hans-Christer; Sperlich, Billy

    2016-02-01

    To compare the effects of a 3-week multimodal rehabilitation involving supervised high-intensity interval training (HIIT) on female breast cancer survivors with respect to key variables of aerobic fitness, body composition, energy expenditure, cancer-related fatigue, and quality of life to those of a standard multimodal rehabilitation program. A randomized controlled trial design was administered. Twenty-eight women, who had been treated for cancer were randomly assigned to either a group performing exercise of low-to-moderate intensity (LMIE; n = 14) or a group performing high-intensity interval training (HIIT; n = 14) as part of a 3-week multimodal rehabilitation program. No adverse events related to the exercise were reported. Work economy improved following both HIIT and LMIE, with improved peak oxygen uptake following LMIE. HIIT reduced mean total body fat mass with no change in body mass, muscle or fat-free mass (best P < 0.06). LMIE increased muscle and total fat-free body mass. Total energy expenditure (P = 0.45) did not change between the groups, whereas both improved quality of life to a similar high extent and lessened cancer-related fatigue. This randomized controlled study demonstrates that HIIT can be performed by female cancer survivors without adverse health effects. Here, HIIT and LMIE both improved work economy, quality of life and cancer-related fatigue, body composition or energy expenditure. Since the outcomes were similar, but HIIT takes less time, this may be a time-efficient strategy for improving certain aspects of the health of female cancer survivors. © 2016 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.

  20. Intensive care unit quality improvement: a "how-to" guide for the interdisciplinary team.

    PubMed

    Curtis, J Randall; Cook, Deborah J; Wall, Richard J; Angus, Derek C; Bion, Julian; Kacmarek, Robert; Kane-Gill, Sandra L; Kirchhoff, Karin T; Levy, Mitchell; Mitchell, Pamela H; Moreno, Rui; Pronovost, Peter; Puntillo, Kathleen

    2006-01-01

    Quality improvement is an important activity for all members of the interdisciplinary critical care team. Although an increasing number of resources are available to guide clinicians, quality improvement activities can be overwhelming. Therefore, the Society of Critical Care Medicine charged this Outcomes Task Force with creating a "how-to" guide that focuses on critical care, summarizes key concepts, and outlines a practical approach to the development, implementation, evaluation, and maintenance of an interdisciplinary quality improvement program in the intensive care unit. The task force met in person twice and by conference call twice to write this document. We also conducted a literature search on "quality improvement" and "critical care or intensive care" and searched online for additional resources. DATA SYNTHESIS AND OVERVIEW: We present an overview of quality improvement in the intensive care unit setting and then describe the following steps for initiating or improving an interdisciplinary critical care quality improvement program: a) identify local motivation, support teamwork, and develop strong leadership; b) prioritize potential projects and choose the first target; c) operationalize the measures, build support for the project, and develop a business plan; d) perform an environmental scan to better understand the problem, potential barriers, opportunities, and resources for the project; e) create a data collection system that accurately measures baseline performance and future improvements; f) create a data reporting system that allows clinicians and others to understand the problem; g) introduce effective strategies to change clinician behavior. In addition, we identify four steps for evaluating and maintaining this program: a) determine whether the target is changing with periodic data collection; b) modify behavior change strategies to improve or sustain improvements; c) focus on interdisciplinary collaboration; and d) develop and sustain support

  1. River water quality changes in New Zealand over 26 years: response to land use intensity

    NASA Astrophysics Data System (ADS)

    Julian, Jason P.; de Beurs, Kirsten M.; Owsley, Braden; Davies-Colley, Robert J.; Ausseil, Anne-Gaelle E.

    2017-02-01

    Relationships between land use and water quality are complex with interdependencies, feedbacks, and legacy effects. Most river water quality studies have assessed catchment land use as areal coverage, but here, we hypothesize and test whether land use intensity - the inputs (fertilizer, livestock) and activities (vegetation removal) of land use - is a better predictor of environmental impact. We use New Zealand (NZ) as a case study because it has had one of the highest rates of agricultural land intensification globally over recent decades. We interpreted water quality state and trends for the 26 years from 1989 to 2014 in the National Rivers Water Quality Network (NRWQN) - consisting of 77 sites on 35 mostly large river systems. To characterize land use intensity, we analyzed spatial and temporal changes in livestock density and land disturbance (i.e., bare soil resulting from vegetation loss by either grazing or forest harvesting) at the catchment scale, as well as fertilizer inputs at the national scale. Using simple multivariate statistical analyses across the 77 catchments, we found that median visual water clarity was best predicted inversely by areal coverage of intensively managed pastures. The primary predictor for all four nutrient variables (TN, NOx, TP, DRP), however, was cattle density, with plantation forest coverage as the secondary predictor variable. While land disturbance was not itself a strong predictor of water quality, it did help explain outliers of land use-water quality relationships. From 1990 to 2014, visual clarity significantly improved in 35 out of 77 (34/77) catchments, which we attribute mainly to increased dairy cattle exclusion from rivers (despite dairy expansion) and the considerable decrease in sheep numbers across the NZ landscape, from 58 million sheep in 1990 to 31 million in 2012. Nutrient concentrations increased in many of NZ's rivers with dissolved oxidized nitrogen significantly increasing in 27/77 catchments, which we

  2. Short-term high-intensity interval training improves phosphocreatine recovery kinetics following moderate-intensity exercise in humans.

    PubMed

    Forbes, Sean C; Slade, Jill M; Meyer, Ronald A

    2008-12-01

    Previous studies have shown that high-intensity training improves biochemical markers of oxidative potential in skeletal muscle within a 2-week period. The purpose of this study was to examine the effect of short-term high-intensity interval training on the time constant () of phosphocreatine (PCr) recovery following moderate-intensity exercise, an in vivo measure of functional oxidative capacity. Seven healthy active subjects (age, 21 +/- 4 years; body mass, 69 +/- 11 kg) performed 6 sessions of 4-6 maximal-effort 30 s cycling intervals within a 2-week period, and 7 subjects (age, 24 +/- 5 years; body mass, 80 +/- 15 kg) served as controls. Prior to and following training, phosphorous-31 magnetic resonance spectroscopy (31P-MRS; GE 3T Excite System) was used to measure relative changes in high-energy phosphates and intracellular pH of the quadriceps muscles during gated dynamic leg-extension exercise (3 cycles of 90 s exercise and 5 min of rest). A monoexponential model was used to estimate the of PCr recovery. The of PCr recovery after leg-extension exercise was reduced by 14% with high-intensity interval training (pretraining, 43 +/- 14 s vs. post-training, 37 +/- 15 s; p < 0.05) with no change in the control group (44 +/- 12 s vs. 43 +/- 12 s, respectively; p > 0.05). These findings demonstrate that short-term high-intensity interval training is an effective means of increasing functional oxidative capacity in skeletal muscle.

  3. Space charge induced resonance excitation in high intensity rings

    NASA Astrophysics Data System (ADS)

    Cousineau, S.; Lee, S. Y.; Holmes, J. A.; Danilov, V.; Fedotov, A.

    2003-03-01

    We present a particle core model study of the space charge effect on high intensity synchrotron beams, with specific emphasis on the Proton Storage Ring (PSR) at Los Alamos National Laboratory. Our particle core model formulation includes realistic lattice focusing and dispersion. We transport both matched and mismatched beams through real lattice structure and compare the results with those of an equivalent uniform-focusing approximation. The effects of lattice structure and finite momentum spread on the resonance behavior are specifically targeted. Stroboscopic maps of the mismatched envelope are constructed and show high-order resonances and stochastic effects that dominate at high mismatch or high intensity. We observe the evolution of the envelope phase-space structure during a high intensity PSR beam accumulation. Finally, we examine the envelope-particle parametric resonance condition and discuss the possibility for halo growth in synchrotron beams due to this mechanism.

  4. Thomson scattering in high-intensity chirped laser pulses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holkundkar, Amol R., E-mail: amol.holkundkar@pilani.bits-pilani.ac.in; Harvey, Chris, E-mail: christopher.harvey@chalmers.se; Marklund, Mattias, E-mail: mattias.marklund@chalmers.se

    2015-10-15

    We consider the Thomson scattering of an electron in an ultra-intense laser pulse. It is well known that at high laser intensities, the frequency and brilliance of the emitted radiation will be greatly reduced due to the electron losing energy before it reaches the peak field. In this work, we investigate the use of a small frequency chirp in the laser pulse in order to mitigate this effect of radiation reaction. It is found that the introduction of a negative chirp means the electron enters a high frequency region of the field while it still has a large proportion ofmore » its original energy. This results in a significant enhancement of the frequency and intensity of the emitted radiation as compared to the case without chirping.« less

  5. High-intensity positron microprobe at Jefferson Lab

    DOE PAGES

    Golge, Serkan; Vlahovic, Branislav; Wojtsekhowski, Bogdan B.

    2014-06-19

    We present a conceptual design for a novel continuous wave electron-linac based high-intensity slow-positron production source with a projected intensity on the order of 10 10 e +/s. Reaching this intensity in our design relies on the transport of positrons (T + below 600 keV) from the electron-positron pair production converter target to a low-radiation and low-temperature area for moderation in a high-efficiency cryogenic rare gas moderator, solid Ne. The performance of the integrated beamline has been verified through computational studies. The computational results include Monte Carlo calculations of the optimized electron/positron beam energies, converter target thickness, synchronized raster system,more » transport of the beam from the converter target to the moderator, extraction of the beam from the channel, and moderation efficiency calculations. For the extraction of positrons from the magnetic channel a magnetic field terminator plug prototype has been built and experimental data on the effectiveness of this prototype are presented. The dissipation of the heat away from the converter target and radiation protection measures are also discussed.« less

  6. Delivery of high intensity beams with large clad step-index fibers for engine ignition

    NASA Astrophysics Data System (ADS)

    Joshi, Sachin; Wilvert, Nick; Yalin, Azer P.

    2012-09-01

    We show, for the first time, that step-index silica fibers with a large clad (400 μm core and 720 μm clad) can be used to transmit nanosecond duration pulses in a way that allows reliable (consistent) spark formation in atmospheric pressure air by the focused output light from the fiber. The high intensity (>100 GW/cm2) of the focused output light is due to the combination of high output power (typical of fibers of this core size) with high output beam quality (better than that typical of fibers of this core size). The high output beam quality, which enables tight focusing, is due to the large clad which suppresses microbending-induced diffusion of modal power to higher order modes owing to the increased rigidity of the core-clad interface. We also show that extending the pulse duration provides a means to increase the delivered pulse energy (>20 mJ delivered for 50 ns pulses) without causing fiber damage. Based on this ability to deliver high energy sparks, we report the first reliable laser ignition of a natural gas engine including startup under typical procedures using silica fiber optics for pulse delivery.

  7. High intensity discharge device containing oxytrihalides

    DOEpatents

    Lapatovich, Walter P.; Keeffe, William M.; Liebermann, Richard W.; Maya, Jakob

    1987-01-01

    A fill composition for a high intensity discharge device including mercury, niobium oxytrihalide, and a molecular stabilization agent is provided. The molar ratio of niobium oxytrihalide to the molecular stabilization agent in the fill is in the range of from about 5:1 to about 7.5:1. Niobium oxytrihalide is present in the fill in sufficient amount to produce, by dissociation in the discharge, atomic niobium, niobium oxide, NbO, and niobium dioxide, NbO.sub.2, with the molar ratio of niobium-containing vapor species to mercury in the fill being in the range of from about 0.01:1 to about 0.50:1; and mercury pressure of about 1 to about 50 atmospheres at lamp operating temperature. There is also provided a high intensity discharge device comprising a sealed light-transmissive arc tube; the arc tube including the above-described fill; and an energizing means for producing an electric discharge within the arc tube.

  8. High intensity discharge device containing oxytrihalides

    DOEpatents

    Lapatovich, W.P.; Keeffe, W.M.; Liebermann, R.W.; Maya, J.

    1987-06-09

    A fill composition for a high intensity discharge device including mercury, niobium oxytrihalide, and a molecular stabilization agent is provided. The molar ratio of niobium oxytrihalide to the molecular stabilization agent in the fill is in the range of from about 5:1 to about 7.5:1. Niobium oxytrihalide is present in the fill in sufficient amount to produce, by dissociation in the discharge, atomic niobium, niobium oxide, NbO, and niobium dioxide, NbO[sub 2], with the molar ratio of niobium-containing vapor species to mercury in the fill being in the range of from about 0.01:1 to about 0.50:1; and mercury pressure of about 1 to about 50 atmospheres at lamp operating temperature. There is also provided a high intensity discharge device comprising a sealed light-transmissive arc tube; the arc tube including the above-described fill; and an energizing means for producing an electric discharge within the arc tube. 7 figs.

  9. Recruiting High Quality Students through a Fifth Year Program: It Can Be Done.

    ERIC Educational Resources Information Center

    James, Terry L.; And Others

    This paper describes the process of recruiting high quality liberal arts graduates into teacher preparation programs at Memphis State University, Tennessee. The two graduate programs, the Master of Arts in Teaching and the Lyndhurst, both require full-time attendance, have lock-step delivery systems and extended internships, and are intensive. In…

  10. The use of indicators to improve the quality of intensive care: theoretical aspects and experiences from the Dutch intensive care registry.

    PubMed

    van der Voort, P H J; van der Veer, S N; de Vos, M L G

    2012-10-01

    In the concept of total quality management that was originally developed in industry, the use of quality indicators is essential. The implementation of quality indicators in the intensive care unit to improve the quality of care is a complex process. This process can be described in seven subsequent steps of an indicator-based quality improvement (IBQI) cycle. With this IBQI cycle, a continuous quality improvement can be achieved with the use of indicator data in a benchmark setting. After the development of evidence-based indicators, a sense of urgency has to be created, registration should start, raw data must be analysed, feedback must be given, and interpretation and conclusions must be made, followed by a quality improvement plan. The last step is the implementation of changes that needs a sense of urgency, and this completes the IBQI cycle. Barriers and facilitators are found in each step. They should be identified and addressed in a multifaceted quality improvement strategy. © 2012 The Authors. Acta Anaesthesiologica Scandinavica © 2012 The Acta Anaesthesiologica Scandinavica Foundation.

  11. Intense highly charged ion beam production and operation with a superconducting electron cyclotron resonance ion source

    NASA Astrophysics Data System (ADS)

    Zhao, H. W.; Sun, L. T.; Guo, J. W.; Lu, W.; Xie, D. Z.; Hitz, D.; Zhang, X. Z.; Yang, Y.

    2017-09-01

    The superconducting electron cyclotron resonance ion source with advanced design in Lanzhou (SECRAL) is a superconducting-magnet-based electron cyclotron resonance ion source (ECRIS) for the production of intense highly charged heavy ion beams. It is one of the best performing ECRISs worldwide and the first superconducting ECRIS built with an innovative magnet to generate a high strength minimum-B field for operation with heating microwaves up to 24-28 GHz. Since its commissioning in 2005, SECRAL has so far produced a good number of continuous wave intensity records of highly charged ion beams, in which recently the beam intensities of 40Ar+ and 129Xe26+ have, for the first time, exceeded 1 emA produced by an ion source. Routine operations commenced in 2007 with the Heavy Ion accelerator Research Facility in Lanzhou (HIRFL), China. Up to June 2017, SECRAL has been providing more than 28,000 hours of highly charged heavy ion beams to the accelerator demonstrating its great capability and reliability. The great achievement of SECRAL is accumulation of numerous technical advancements, such as an innovative magnetic system and an efficient double-frequency (24 +18 GHz ) heating with improved plasma stability. This article reviews the development of SECRAL and production of intense highly charged ion beams by SECRAL focusing on its unique magnet design, source commissioning, performance studies and enhancements, beam quality and long-term operation. SECRAL development and its performance studies representatively reflect the achievements and status of the present ECR ion source, as well as the ECRIS impacts on HIRFL.

  12. Restoration of MRI data for intensity non-uniformities using local high order intensity statistics

    PubMed Central

    Hadjidemetriou, Stathis; Studholme, Colin; Mueller, Susanne; Weiner, Michael; Schuff, Norbert

    2008-01-01

    MRI at high magnetic fields (>3.0 T) is complicated by strong inhomogeneous radio-frequency fields, sometimes termed the “bias field”. These lead to non-biological intensity non-uniformities across the image. They can complicate further image analysis such as registration and tissue segmentation. Existing methods for intensity uniformity restoration have been optimized for 1.5 T, but they are less effective for 3.0 T MRI, and not at all satisfactory for higher fields. Also, many of the existing restoration algorithms require a brain template or use a prior atlas, which can restrict their practicalities. In this study an effective intensity uniformity restoration algorithm has been developed based on non-parametric statistics of high order local intensity co-occurrences. These statistics are restored with a non-stationary Wiener filter. The algorithm also assumes a smooth non-uniformity and is stable. It does not require a prior atlas and is robust to variations in anatomy. In geriatric brain imaging it is robust to variations such as enlarged ventricles and low contrast to noise ratio. The co-occurrence statistics improve robustness to whole head images with pronounced non-uniformities present in high field acquisitions. Its significantly improved performance and lower time requirements have been demonstrated by comparing it to the very commonly used N3 algorithm on BrainWeb MR simulator images as well as on real 4 T human head images. PMID:18621568

  13. Proton-induced Nuclear Reactions Using Compact High-Contrast High-Intensity Laser

    NASA Astrophysics Data System (ADS)

    Ogura, Koichi; Shizuma, Toshiyuki; Hayakawa, Takehito; Yogo, Akifumi; Nishiuchi, Mamiko; Orimo, Satoshi; Sagisaka, Akito; Pirozhkov, Alexander; Mori, Michiaki; Kiriyama, Hiromitsu; Kanazawa, Shuhei; Kondo, Shunji; Nakai, Yoshiki; Shimoura, Takuya; Tanoue, Manabu; Akutsu, Atsushi; Motomura, Tomohiro; Okada, Hajime; Kimura, Toyoaki; Oishi, Yuji; Nayuki, Takuya; Fujii, Takashi; Nemoto, Koshichi; Daido, Hiroyuki

    2009-06-01

    A multi-MeV proton beam driven by a compact laser with an intensity of ˜1020 W/cm2 is used to induce the nuclear reaction 11B(p,n)11C. The total activity of 11C produced after 60 shots of laser irradiation is found to be 11.1+/-0.4 Bq. The possibility of thin layer activation (TLA) analysis using a high-intensity ultrashort-pulse laser is discussed.

  14. Effects of High-Intensity Interval Training versus Continuous Training on Physical Fitness, Cardiovascular Function and Quality of Life in Heart Failure Patients.

    PubMed

    Benda, Nathalie M M; Seeger, Joost P H; Stevens, Guus G C F; Hijmans-Kersten, Bregina T P; van Dijk, Arie P J; Bellersen, Louise; Lamfers, Evert J P; Hopman, Maria T E; Thijssen, Dick H J

    2015-01-01

    Physical fitness is an important prognostic factor in heart failure (HF). To improve fitness, different types of exercise have been explored, with recent focus on high-intensity interval training (HIT). We comprehensively compared effects of HIT versus continuous training (CT) in HF patients NYHA II-III on physical fitness, cardiovascular function and structure, and quality of life, and hypothesize that HIT leads to superior improvements compared to CT. Twenty HF patients (male:female 19:1, 64±8 yrs, ejection fraction 38±6%) were allocated to 12-weeks of HIT (10*1-minute at 90% maximal workload-alternated by 2.5 minutes at 30% maximal workload) or CT (30 minutes at 60-75% of maximal workload). Before and after intervention, we examined physical fitness (incremental cycling test), cardiac function and structure (echocardiography), vascular function and structure (ultrasound) and quality of life (SF-36, Minnesota living with HF questionnaire (MLHFQ)). Training improved maximal workload, peak oxygen uptake (VO2peak) related to the predicted VO2peak, oxygen uptake at the anaerobic threshold, and maximal oxygen pulse (all P<0.05), whilst no differences were present between HIT and CT (N.S.). We found no major changes in resting cardiovascular function and structure. SF-36 physical function score improved after training (P<0.05), whilst SF-36 total score and MLHFQ did not change after training (N.S.). Training induced significant improvements in parameters of physical fitness, although no evidence for superiority of HIT over CT was demonstrated. No major effect of training was found on cardiovascular structure and function or quality of life in HF patients NYHA II-III. Nederlands Trial Register NTR3671.

  15. Real-time bilinear rotation decoupling in absorptive mode J-spectroscopy: Detecting low-intensity metabolite peak close to high-intensity metabolite peak with convenience

    NASA Astrophysics Data System (ADS)

    Verma, Ajay; Baishya, Bikash

    2016-05-01

    ;Pure shift; NMR spectra display singlet peak per chemical site. Thus, high resolution is offered at the cost of valuable J-coupling information. In the present work, real-time BIRD (BIlinear Rotation Decoupling) is applied to the absorptive-mode 2D J-spectroscopy to provide pure shift spectrum in the direct dimension and J-coupling information in the indirect dimension. Quite often in metabolomics, proton NMR spectra from complex bio-fluids display tremendous signal overlap. Although conventional J-spectroscopy in principle overcomes this problem by separating the multiplet information from chemical shift information, however, only magnitude mode of the experiment is practical, sacrificing much of the potential high resolution that could be achieved. Few J-spectroscopy methods have been reported so far that produce high-resolution pure shift spectrum along with J-coupling information for crowded spectral regions. In the present work, high-quality J-resolved spectrum from important metabolomic mixture such as tissue extract from rat cortex is demonstrated. Many low-intensity metabolite peaks which are obscured by the broad dispersive tails from high-intensity metabolite peaks in regular magnitude mode J-spectrum can be clearly identified in real-time BIRD J-resolved spectrum. The general practice of removing such spectral overlap is tedious and time-consuming as it involves repeated sample preparation to change the pH of the tissue extract sample and subsequent spectra recording.

  16. Gaussian representation of high-intensity focused ultrasound beams.

    PubMed

    Soneson, Joshua E; Myers, Matthew R

    2007-11-01

    A method for fast numerical simulation of high-intensity focused ultrasound beams is derived. The method is based on the frequency-domain representation of the Khokhlov-Zabolotskaya-Kuznetsov (KZK) equation, and assumes for each harmonic a Gaussian transverse pressure distribution at all distances from the transducer face. The beamwidths of the harmonics are constrained to vary inversely with the square root of the harmonic number, and as such this method may be viewed as an extension of a quasilinear approximation. The technique is capable of determining pressure or intensity fields of moderately nonlinear high-intensity focused ultrasound beams in water or biological tissue, usually requiring less than a minute of computer time on a modern workstation. Moreover, this method is particularly well suited to high-gain simulations since, unlike traditional finite-difference methods, it is not subject to resolution limitations in the transverse direction. Results are shown to be in reasonable agreement with numerical solutions of the full KZK equation in both tissue and water for moderately nonlinear beams.

  17. High-Intensity Training and Salivary Immunoglobulin A Responses in Professional Top-Level Soccer Players: Effect of Training Intensity.

    PubMed

    Owen, Adam L; Wong, Del P; Dunlop, Gordon; Groussard, Carole; Kebsi, Wiem; Dellal, Alexandre; Morgans, Ryland; Zouhal, Hassane

    2016-09-01

    Owen, AL, Wong, DP, Dunlop, G, Groussard, C, Kebsi, W, Dellal, A, Morgans, R, and Zouhal, H. High-intensity training and salivary immunoglobulin A responses in professional top-level soccer players: Effect of training intensity. J Strength Cond Res 30(9): 2460-2469, 2016-This study aimed (a) to test the hypothesis that salivary immunoglobulin A (s-IgA) would vary with training intensity sessions (low-intensity [LI] vs. high-intensity sessions [HI]) during a traditional training program divided into 4 training periods and (b) to identify key variables (e.g., GPS data, rating of perceived exertion [RPE], and training duration), which could affect s-IgA. Saliva samples of 10 elite professional soccer players were collected (a) before the investigation started to establish the baseline level and (b) before and after each 4 training sessions (LI vs. HI). Training intensity was monitored as internal (through heart rate responses and RPE) and external (through GPS) loads. High-intensity sessions were associated with higher external load (GPS) and with higher RPE. Baseline and pretraining s-IgA did not differ between the 4 training sessions both for HI and LI. Post-training s-IgA were not different (in absolute value and in percentage of change) between HI and LI sessions at the first 3 periods. However, at the fourth period, s-IgA concentration for HI session was significantly lower (p ≤ 0.05) than the LI session. The percentage change between s-IgA post-training and s-IgA baseline concentrations differ significantly (p ≤ 0.05) between HI and LI training sessions. Significant correlations between s-IgA and training intensity were also noted. High-intensity soccer training sessions might cause a significant decrease in s-IgA values during the postexercise window as compared with LI sessions. This study encourages coaches to monitor s-IgA in routine, particularly during HI training periods, to take precautions to avoid upper respiratory tract infection in highly trained

  18. High-intensity sound in air saturated fibrous bulk porous materials

    NASA Technical Reports Server (NTRS)

    Kuntz, H. L., II

    1982-01-01

    The interaction high-intensity sound with bulk porous materials in porous materials including Kevlar 29 is reported. The nonlinear behavior of the materials was described by dc flow resistivity tests. Then acoustic propagation and reflection were measured and small signal broadband measurements of phase speed and attenuation were carried out. High-intensity tests were made with 1, 2, and 3 kHz tone bursts to measure harmonic generation and extra attenuation of the fundamental. Small signal standing wave tests measured impedence between 0.1 and 3.5 kHz. High level tests with single cycle tone bursts at 1 to 4 kHz show that impedance increases with intensity. A theoretical analysis is presented for high-porosity, rigid-frame, isothermal materials. One dimensional equations of motion are derived and solved by perturbation. The experiments show that there is excess attenuation of the fundamental component and in some cases a close approach to saturation. A separate theoretical model, developed to explain the excess attenuation, yields predictions that are in good agreement with the measurements. Impedance and attenuation at high intensities are modeled.

  19. 14 CFR 23.1308 - High-intensity Radiated Fields (HIRF) Protection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false High-intensity Radiated Fields (HIRF... Equipment General § 23.1308 High-intensity Radiated Fields (HIRF) Protection. (a) Except as provided in paragraph (d) of this section, each electrical and electronic system that performs a function whose failure...

  20. 14 CFR 23.1308 - High-intensity Radiated Fields (HIRF) Protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false High-intensity Radiated Fields (HIRF... Equipment General § 23.1308 High-intensity Radiated Fields (HIRF) Protection. (a) Except as provided in paragraph (d) of this section, each electrical and electronic system that performs a function whose failure...

  1. Confidential inquiry into quality of care before admission to intensive care

    PubMed Central

    McQuillan, Peter; Pilkington, Sally; Allan, Alison; Taylor, Bruce; Short, Alasdair; Morgan, Giles; Nielsen, Mick; Barrett, David; Smith, Gary

    1998-01-01

    Objective: To examine the prevalence, nature, causes, and consequences of suboptimal care before admission to intensive care units, and to suggest possible solutions. Design: Prospective confidential inquiry on the basis of structured interviews and questionnaires. Setting: A large district general hospital and a teaching hospital. Subjects: A cohort of 100 consecutive adult emergency admissions, 50 in each centre. Main outcome measures: Opinions of two external assessors on quality of care especially recognition, investigation, monitoring, and management of abnormalities of airway, breathing, and circulation, and oxygen therapy and monitoring. Results: Assessors agreed that 20 patients were well managed (group 1) and 54 patients received suboptimal care (group 2). Assessors disagreed on quality of management of 26 patients (group 3). The casemix and severity of illness, defined by the acute physiology and chronic health evaluation (APACHE II) score, were similar between centres and the three groups. In groups 1, 2, and 3 intensive care mortalities were 5 (25%), 26 (48%), and 6 (23%) respectively (P=0.04) (group 1 versus group 2, P=0.07). Hospital mortalities were 7 (35%), 30 (56%), and 8 (31%) (P=0.07) and standardised hospital mortality ratios (95% confidence intervals) were 1.23 (0.49 to 2.54), 1.4 (0.94 to 2.0), and 1.26 (0.54 to 2.48) respectively. Admission to intensive care was considered late in 37 (69%) patients in group 2. Overall, a minimum of 4.5% and a maximum of 41% of admissions were considered potentially avoidable. Suboptimal care contributed to morbidity or mortality in most instances. The main causes of suboptimal care were failure of organisation, lack of knowledge, failure to appreciate clinical urgency, lack of supervision, and failure to seek advice. Conclusions: The management of airway, breathing, and circulation, and oxygen therapy and monitoring in severely ill patients before admission to intensive care units may frequently be suboptimal

  2. Optical waveguide and room temperature high-quality nanolasers from tin-catalyzed CdSSe nanostructures

    NASA Astrophysics Data System (ADS)

    Guo, Pengfei; Shen, Xia; Zhang, Baolong; Sun, Haibin; Zou, Zhijun; Yang, Wenchao; Gong, Ke; Luo, Yongsong

    2018-05-01

    A simple two-step CVD method is developed to realize the growth of high-quality tin-catalyzed CdSSe alloy nanowires. Microstructural characterizations demonstrate that these wires are high-quality crystalline nanostructures. Local photoluminescence investigation of these nanostructures shows a typical band edge emission at 656 nm with a full-width at half-maximum of 22.3 nm. Optical waveguide measurement along an individual nanowire indicates that the output signal of the guided light has a rapid linear decrease accompanied with maximum red-shift about 109 meV after the transmission of 102 μm. This obvious red-shift is caused by the intensive band-tail absorption during the optical transmission process. Moreover, optically pumped nanolasers are successfully realized at room temperature based on these unique wires, further demonstrating the achievement of stimulated emission from spontaneous emission, promoted by the pump power intensity. This work may find a simple route to the manufacture of superior nanowires for applications in waveguide and integrated photonic devices.

  3. Optical waveguide and room temperature high-quality nanolasers from tin-catalyzed CdSSe nanostructures.

    PubMed

    Guo, Pengfei; Shen, Xia; Zhang, Baolong; Sun, Haibin; Zou, Zhijun; Yang, Wenchao; Gong, Ke; Luo, Yongsong

    2018-05-04

    A simple two-step CVD method is developed to realize the growth of high-quality tin-catalyzed CdSSe alloy nanowires. Microstructural characterizations demonstrate that these wires are high-quality crystalline nanostructures. Local photoluminescence investigation of these nanostructures shows a typical band edge emission at 656 nm with a full-width at half-maximum of 22.3 nm. Optical waveguide measurement along an individual nanowire indicates that the output signal of the guided light has a rapid linear decrease accompanied with maximum red-shift about 109 meV after the transmission of 102 μm. This obvious red-shift is caused by the intensive band-tail absorption during the optical transmission process. Moreover, optically pumped nanolasers are successfully realized at room temperature based on these unique wires, further demonstrating the achievement of stimulated emission from spontaneous emission, promoted by the pump power intensity. This work may find a simple route to the manufacture of superior nanowires for applications in waveguide and integrated photonic devices.

  4. Health-related quality of life after salvage high-intensity focused ultrasound (HIFU) treatment for locally radiorecurrent prostate cancer.

    PubMed

    Berge, Viktor; Baco, Eduard; Dahl, Alv A; Karlsen, Steinar Johan

    2011-09-01

    To evaluate health-related quality of life (HRQOL) after salvage high-intensity focused ultrasound (HIFU) for locally radiorecurrent prostate cancer (PCa). Since June 2006 we have treated 61 patients consecutively by salvage HIFU. All patients were offered the University of California, Los Angeles Prostate Cancer Index (UCLA-PCI) questionnaire at baseline and at follow-up. Scores ranged from 0 (worst) to 100 (best). Clinically significant changes were defined as a minimum difference of 10 points between the baseline score and the score at follow-up.   Fifty-seven patients (93%) had evaluable data at baseline, compared with 46 (75%) after treatment. The mean time lapse between HIFU treatment and questionnaire response was 17.5 months (range 6-29 months). The mean score for urinary function decreased from 79.7 ± 12.1 prior to HIFU to 67.4 ± 17.8 after HIFU (P < 0.001). The mean score for sexual function decreased from 32.1 ± 24.1 prior to HIFU to 17.2 ± 17.0 after HIFU (P < 0.001). There were no significant effects on bowel function. There was a significant reduction in the mean score for Physical HRQOL, but the mean score for Mental HRQOL was did not change significantly. Treatment of localized radiorecurrent PCa by salvage HIFU is associated with clinically significant reductions in urinary and sexual function domains after a mean follow-up of 17.5 months. © 2011 The Japanese Urological Association.

  5. ARRONAX, a high-energy and high-intensity cyclotron for nuclear medicine.

    PubMed

    Haddad, Ferid; Ferrer, Ludovic; Guertin, Arnaud; Carlier, Thomas; Michel, Nathalie; Barbet, Jacques; Chatal, Jean-François

    2008-07-01

    This study was aimed at establishing a list of radionuclides of interest for nuclear medicine that can be produced in a high-intensity and high-energy cyclotron. We have considered both therapeutic and positron emission tomography radionuclides that can be produced using a high-energy and a high-intensity cyclotron such as ARRONAX, which will be operating in Nantes (France) by the end of 2008. Novel radionuclides or radionuclides of current limited availability have been selected according to the following criteria: emission of positrons, low-energy beta or alpha particles, stable or short half-life daughters, half-life between 3 h and 10 days or generator-produced, favourable dosimetry, production from stable isotopes with reasonable cross sections. Three radionuclides appear well suited to targeted radionuclide therapy using beta ((67)Cu, (47)Sc) or alpha ((211)At) particles. Positron emitters allowing dosimetry studies prior to radionuclide therapy ((64)Cu, (124)I, (44)Sc), or that can be generator-produced ((82)Rb, (68)Ga) or providing the opportunity of a new imaging modality ((44)Sc) are considered to have a great interest at short term whereas (86)Y, (52)Fe, (55)Co, (76)Br or (89)Zr are considered to have a potential interest at middle term. Several radionuclides not currently used in routine nuclear medicine or not available in sufficient amount for clinical research have been selected for future production. High-energy, high-intensity cyclotrons are necessary to produce some of the selected radionuclides and make possible future clinical developments in nuclear medicine. Associated with appropriate carriers, these radionuclides will respond to a maximum of unmet clinical needs.

  6. Application of the Speed-Duration Relationship to Normalize the Intensity of High-Intensity Interval Training

    PubMed Central

    Ferguson, Carrie; Wilson, John; Birch, Karen M.; Kemi, Ole J.

    2013-01-01

    The tolerable duration of continuous high-intensity exercise is determined by the hyperbolic Speed-tolerable duration (S-tLIM) relationship. However, application of the S-tLIM relationship to normalize the intensity of High-Intensity Interval Training (HIIT) has yet to be considered, with this the aim of present study. Subjects completed a ramp-incremental test, and series of 4 constant-speed tests to determine the S-tLIM relationship. A sub-group of subjects (n = 8) then repeated 4 min bouts of exercise at the speeds predicted to induce intolerance at 4 min (WR4), 6 min (WR6) and 8 min (WR8), interspersed with bouts of 4 min recovery, to the point of exercise intolerance (fixed WR HIIT) on different days, with the aim of establishing the work rate that could be sustained for 960 s (i.e. 4×4 min). A sub-group of subjects (n = 6) also completed 4 bouts of exercise interspersed with 4 min recovery, with each bout continued to the point of exercise intolerance (maximal HIIT) to determine the appropriate protocol for maximizing the amount of high-intensity work that can be completed during 4×4 min HIIT. For fixed WR HIIT tLIM of HIIT sessions was 399±81 s for WR4, 892±181 s for WR6 and 1517±346 s for WR8, with total exercise durations all significantly different from each other (P<0.050). For maximal HIIT, there was no difference in tLIM of each of the 4 bouts (Bout 1: 229±27 s; Bout 2: 262±37 s; Bout 3: 235±49 s; Bout 4: 235±53 s; P>0.050). However, there was significantly less high-intensity work completed during bouts 2 (153.5±40. 9 m), 3 (136.9±38.9 m), and 4 (136.7±39.3 m), compared with bout 1 (264.9±58.7 m; P>0.050). These data establish that WR6 provides the appropriate work rate to normalize the intensity of HIIT between subjects. Maximal HIIT provides a protocol which allows the relative contribution of the work rate profile to physiological adaptations to be considered during alternative intensity-matched HIIT protocols. PMID:24244266

  7. High Intensity Interval Training for Maximizing Health Outcomes.

    PubMed

    Karlsen, Trine; Aamot, Inger-Lise; Haykowsky, Mark; Rognmo, Øivind

    Regular physical activity and exercise training are important actions to improve cardiorespiratory fitness and maintain health throughout life. There is solid evidence that exercise is an effective preventative strategy against at least 25 medical conditions, including cardiovascular disease, stroke, hypertension, colon and breast cancer, and type 2 diabetes. Traditionally, endurance exercise training (ET) to improve health related outcomes has consisted of low- to moderate ET intensity. However, a growing body of evidence suggests that higher exercise intensities may be superior to moderate intensity for maximizing health outcomes. The primary objective of this review is to discuss how aerobic high-intensity interval training (HIIT) as compared to moderate continuous training may maximize outcomes, and to provide practical advices for successful clinical and home-based HIIT. Copyright © 2017. Published by Elsevier Inc.

  8. Quality assurance in an adult intensive care unit, Eastern region, Saudi Arabia.

    PubMed

    Iqbal, Mobeen; Rehmani, Rifat; Venter, Joan; Alaithan, Abdulsalam M

    2007-03-01

    Quality assurance (QA) is an increasingly important element in the administrative management of Intensive Care Unit (ICU). This is not only to improve clinical practices and patient's outcome, but also helps in proper resource utilization. We introduced a comprehensive quality assurance program in ICU at King Abdulaziz National Guard Hospital, Alhasa, Saudi Arabia, based on the existing medical evidence. We identified an already-validated set of quality indicators in intensive care and grouped them in categories of outcome measures (which reflect patient's subsequent health status) and process measures (related to patient-healthcare professional's interaction). Data collection forms were developed for nurses and physicians. Data were reported on monthly basis starting from January 2005, and the first 10 months data are presented. Three hundred eighty-seven patients were admitted during the study period. Approximately 56.9% had cardiac related diseases, 33.5% had medical ailments, and 9.6% had surgery related issues. There were 54.6% males and 45.4% females. Mean age of the patients was 58.4 +/- 18.3 years. The mean acute physiology and chronic health evaluation II (APACHE-II) score was 13.6 +/- 4.9. Outcome measures were either better or comparable to international data, while adherence to process measures was found to be excellent. Standardized mortality ratio for the duration of study was 0.24 with 95% confidence interval from 0.15-0.36. Implementation of QA program is practical in an ICU. Disseminating the quality monitoring information at national level can lead to a broad data base, which can identify the best performing ICUs, thus, leading to bench marking and creating risk adjusted models applicable to local population.

  9. Generalized Courant-Snyder Theory and Kapchinskij-Vladimirskij Distribution For High-intensity Beams In A Coupled Transverse Focusing Lattice

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hong QIn, Ronald Davidson

    2011-07-18

    The Courant-Snyder (CS) theory and the Kapchinskij-Vladimirskij (KV) distribution for high-intensity beams in a uncoupled focusing lattice are generalized to the case of coupled transverse dynamics. The envelope function is generalized to an envelope matrix, and the envelope equation becomes a matrix envelope equation with matrix operations that are non-commutative. In an uncoupled lattice, the KV distribution function, first analyzed in 1959, is the only known exact solution of the nonlinear Vlasov-Maxwell equations for high-intensity beams including self-fields in a self-consistent manner. The KV solution is generalized to high-intensity beams in a coupled transverse lattice using the generalized CS invariant.more » This solution projects to a rotating, pulsating elliptical beam in transverse configuration space. The fully self-consistent solution reduces the nonlinear Vlasov-Maxwell equations to a nonlinear matrix ordinary differential equation for the envelope matrix, which determines the geometry of the pulsating and rotating beam ellipse. These results provide us with a new theoretical tool to investigate the dynamics of high-intensity beams in a coupled transverse lattice. A strongly coupled lattice, a so-called N-rolling lattice, is studied as an example. It is found that strong coupling does not deteriorate the beam quality. Instead, the coupling induces beam rotation, and reduces beam pulsation.« less

  10. Generalized Courant-Snyder theory and Kapchinskij-Vladimirskij distribution for high-intensity beams in a coupled transverse focusing lattice

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qin Hong; Department of Modern Physics, University of Science and Technology of China, Hefei, Anhui 230026; Davidson, Ronald C.

    2011-05-15

    The Courant-Snyder (CS) theory and the Kapchinskij-Vladimirskij (KV) distribution for high-intensity beams in an uncoupled focusing lattice are generalized to the case of coupled transverse dynamics. The envelope function is generalized to an envelope matrix, and the envelope equation becomes a matrix envelope equation with matrix operations that are noncommutative. In an uncoupled lattice, the KV distribution function, first analyzed in 1959, is the only known exact solution of the nonlinear Vlasov-Maxwell equations for high-intensity beams including self-fields in a self-consistent manner. The KV solution is generalized to high-intensity beams in a coupled transverse lattice using the generalized CS invariant.more » This solution projects to a rotating, pulsating elliptical beam in transverse configuration space. The fully self-consistent solution reduces the nonlinear Vlasov-Maxwell equations to a nonlinear matrix ordinary differential equation for the envelope matrix, which determines the geometry of the pulsating and rotating beam ellipse. These results provide us with a new theoretical tool to investigate the dynamics of high-intensity beams in a coupled transverse lattice. A strongly coupled lattice, a so-called N-rolling lattice, is studied as an example. It is found that strong coupling does not deteriorate the beam quality. Instead, the coupling induces beam rotation and reduces beam pulsation.« less

  11. The high intensity solar cell: Key to low cost photovoltaic power

    NASA Technical Reports Server (NTRS)

    Sater, B. L.; Goradia, C.

    1975-01-01

    The design considerations and performance characteristics of the 'high intensity' (HI) solar cell are presented. A high intensity solar system was analyzed to determine its cost effectiveness and to assess the benefits of further improving HI cell efficiency. It is shown that residential sized systems can be produced at less than $1000/kW peak electric power. Due to their superior high intensity performance characteristics compared to the conventional and VMJ cells, HI cells and light concentrators may be the key to low cost photovoltaic power.

  12. High-intensity exercise training induces morphological and biochemical changes in skeletal muscles.

    PubMed

    Toti, L; Bartalucci, A; Ferrucci, M; Fulceri, F; Lazzeri, G; Lenzi, P; Soldani, P; Gobbi, P; La Torre, A; Gesi, M

    2013-12-01

    IN THE PRESENT STUDY WE INVESTIGATED THE EFFECT OF TWO DIFFERENT EXERCISE PROTOCOLS ON FIBRE COMPOSITION AND METABOLISM OF TWO SPECIFIC MUSCLES OF MICE: the quadriceps and the gastrocnemius. Mice were run daily on a motorized treadmill, at a velocity corresponding to 60% or 90% of the maximal running velocity. Blood lactate and body weight were measured during exercise training. We found that at the end of training the body weight significantly increased in high-intensity exercise mice compared to the control group (P=0.0268), whereas it decreased in low-intensity exercise mice compared to controls (P=0.30). In contrast, the food intake was greater in both trained mice compared to controls (P < 0.0001 and P < 0.0001 for low-intensity and high-intensity exercise mice, respectively). These effects were accompanied by a progressive reduction in blood lactate levels at the end of training in both the exercised mice compared with controls (P=0.03 and P < 0.0001 for low-intensity and high-intensity exercise mice, respectively); in particular, blood lactate levels after high-intensity exercise were significantly lower than those measured in low-intensity exercise mice (P=0.0044). Immunoblotting analysis demonstrated that high-intensity exercise training produced a significant increase in the expression of mitochondrial enzymes contained within gastrocnemius and quadriceps muscles. These changes were associated with an increase in the amount of slow fibres in both these muscles of high-intensity exercise mice, as revealed by the counts of slow fibres stained with specific antibodies (P < 0.0001 for the gastrocnemius; P=0.0002 for the quadriceps). Our results demonstrate that high-intensity exercise, in addition to metabolic changes consisting of a decrease in blood lactate and body weight, induces an increase in the mitochondrial enzymes and slow fibres in different skeletal muscles of mice, which indicates an exercise-induced increase in the aerobic metabolism.

  13. High-intensity and resistance training and elite young athletes.

    PubMed

    Ratel, Sébastien

    2011-01-01

    Although in the past resistance and high-intensity exercise training among young children was the subject of numerous controversies, it is now well-documented that this training mode is a safe and effective means of developing maximal strength, maximal power output and athletic performance in youth, provided that exercises are performed with appropriate supervision and precautions. Muscular strength and power output values measured from vertical jump and Wingate anaerobic tests are higher in elite than in non-elite young athletes and normal children, and the specific training effects on maximal power output normalised for body size are clearly more distinct before puberty. At present, there is no scientific evidence to support the view that high-intensity and/or resistance training might hinder growth and maturation in young children. Pre-pubertal growth is not adversely affected by sport at a competitive level and anthropometric factors are of importance for choice of sport in children. However, coaches, teachers and parents should be aware that unsupervised high-intensity and resistance training programmes involving maximal loads or too frequently repeated resistance exercises increase the risk of injury. Resistance training alone is an effective additional means of developing athletic performance throughout planned youth sports training programmes. Strategies for enhancing the effectiveness and safety of youth resistance and high-intensity exercise training are discussed in this chapter. Copyright © 2011 S. Karger AG, Basel.

  14. An improved multi-exposure approach for high quality holographic femtosecond laser patterning

    NASA Astrophysics Data System (ADS)

    Zhang, Chenchu; Hu, Yanlei; Li, Jiawen; Lao, Zhaoxin; Ni, Jincheng; Chu, Jiaru; Huang, Wenhao; Wu, Dong

    2014-12-01

    High efficiency two photon polymerization through single exposure via spatial light modulator (SLM) has been used to decrease the fabrication time and rapidly realize various micro/nanostructures, but the surface quality remains a big problem due to the speckle noise of optical intensity distribution at the defocused plane. Here, a multi-exposure approach which used tens of computer generate holograms successively loaded on SLM is presented to significantly improve the optical uniformity without losing efficiency. By applying multi-exposure, we found that the uniformity at the defocused plane was increased from ˜0.02 to ˜0.6 according to our simulation. The fabricated two series of letters "HELLO" and "USTC" under single-and multi-exposure in our experiment also verified that the surface quality was greatly improved. Moreover, by this method, several kinds of beam splitters with high quality, e.g., 2 × 2, 5 × 5 Daman, and complex nonseperate 5 × 5, gratings were fabricated with both of high quality and short time (<1 min, 95% time-saving). This multi-exposure SLM-two-photon polymerization method showed the promising prospect in rapidly fabricating and integrating various binary optical devices and their systems.

  15. Ion source and injection line for high intensity medical cyclotron

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jia, XianLu, E-mail: jiaxl@ciae.ac.cn; Guan, Fengping; Yao, Hongjuan

    2014-02-15

    A 14 MeV high intensity compact cyclotron, CYCIAE-14, was built at China Institute of Atomic Energy (CIAE). An injection system based on the external H− ion source was used on CYCIAE-14 so as to provide high intensity beam, while most positron emission tomography cyclotrons adopt internal ion source. A beam intensity of 100 μA/14 MeV was extracted from the cyclotron with a small multi-cusp H− ion source (CIAE-CH-I type) and a short injection line, which the H− ion source of 3 mA/25 keV H− beam with emittance of 0.3π mm mrad and the injection line of with only 1.2 m from themore » extraction of ion source to the medial plane of the cyclotron. To increase the extracted beam intensity of the cyclotron, a new ion source (CIAE-CH-II type) of 9.1 mA was used, with maximum of 500 μA was achieved from the cyclotron. The design and test results of the ion source and injection line optimized for high intensity acceleration will be given in this paper.« less

  16. The Different Calcium+2 Intensity Profile and Quality of Oocyte and Goat Sperms after Cryopreservation

    NASA Astrophysics Data System (ADS)

    Ciptadi, G.; Rahayu, S.; Fatchiyah; Wahyuningsih, S.; Budiarto, A.; Nasich, M.; Putri, A. R. I.; Mudawamah, M.; Ihsan, M. N.

    2018-02-01

    This research aims were to study the effect of the oocyte and sperms cryopreservation of Indonesian local goat on the post-thawing quality and profile or characters of Calcium+2 intensity in relating with their fertility capacity. A study was conducted to test the freezing method and post-thawing viability both stock cells stored in the deep freezer and liquid nitrogen (-80°C of vs -196°C). A fertility test of sperms has been conducted through in vitro of sperm quality, while the oocytes cryopreserved test was done by in vitro maturation (IVM) rate (%). The profile of Calcium 2+ was performed and analysis by Confocal Laser Scanned Microscope (CLSM). The result showed that IVM rate of goat oocyte is considered lower when cryopreserved in -80°C than in -196°C. Meanwhile, sperm is considered having a good quality in 2 methods of cryopreservation with post-thawing motility > 40 % (SNI 2014). There is an important difference between Calcium intensity of fresh and post-thawing both for oocyte and spermatozoa. Calcium +2 profiles is varied individually on the peak of intensity, but it considered expressed the same profile of each fresh and post-thawing cell. In vitro fertilization test need to be performed to complete the viability and fertility competence of these sperm and oocyte freezing stocks.

  17. THE HIGH INTENSITY SOLAR ENVIRONMENT TEST SYSTEM

    NASA Image and Video Library

    2016-01-15

    TODD SCHNEIDER LOOKS UP FROM WORK AT THE DOOR OF T HE HIGH INTENSITY SOLAR ENVIRONMENT TEST SYSTEM IN BUILDING 4605. SCHNEIDER IS A PHYSICIST IN THE MATERIALS AND PROCESSES DEPARTMENT AT MSFC AND IS PRINCIPAL INVESTIGATOR FOR HISET.

  18. Water intake accelerates parasympathetic reactivation after high-intensity exercise.

    PubMed

    Peçanha, Tiago; Paula-Ribeiro, Marcelle; Campana-Rezende, Edson; Bartels, Rhenan; Marins, João Carlos; de Lima, Jorge Roberto

    2014-10-01

    It has been shown that water intake (WI) improves postexercise parasympathetic recovery after moderate-intensity exercise session. However, the potential cardiovascular benefit promoted by WI has not been investigated after high-intensity exercise. To assess the effects of WI on post high-intensity parasympathetic recovery. Twelve recreationally active young men participated in the study (22 ± 1.4 years, 24.1 ± 1.6 kg.m(-2)). The experimental protocol consisted of two visits to the laboratory. Each visit consisted in the completion of a 30-min high-intensity [~80% of maximal heart rate (HR)] cycle ergometer aerobic session performing randomly the WI or control (CON, no water consumption) intervention at the end of the exercise. HR and RR intervals (RRi) were continuously recorded by a heart rate monitor before, during and after the exercise. Differences in HR recovery [e.g., absolute heart rate decrement after 1 min of recovery (HRR60s) and time-constant of the first order exponential fitting curve of the HRR (HRRτ)] and in postexercise vagal-related heart rate variability (HRV) indexes (rMSSD30s, rMSSD, pNN50, SD1 and HF) were calculated and compared for WI and CON. A similar HR recovery and an increased postexercise HRV [SD1 = 9.4 ± 5.9 vs. 6.0 ± 3.9 millisecond, HF(ln) = 3.6 ± 1.4 vs. 2.4 ± 1.3 millisecond(2), for WI and CON, respectively; p < .05] was observed in WI compared with CON. The results suggest that WI accelerates the postexercise parasympathetic reactivation after high-intensity exercise. Such outcome reveals an important cardioprotective effect of WI.

  19. Perceived Stress and Professional Quality of Life in Neonatal Intensive Care Unit Nurses in Gujarat, India.

    PubMed

    Amin, Amee A; Vankar, Jagdish R; Nimbalkar, Somashekhar M; Phatak, Ajay G

    2015-11-01

    To study the levels of perceived stress in Neonatal Intensive Care Unit (NICU) nurses and its association with professional quality of life domains viz. compassion satisfaction, burnout and secondary trauma. In this multicenter, cross sectional study, data was collected by surveying 129 nurses from nine NICUs across six cities of Gujarat, India using demographic questionnaire, Perceived Stress Scale (PSS14) and Professional Quality of Life Scale (ProQOL5) during July to September 2013. Descriptive statistics, correlation coefficient and multiple regression were used for analysis. The mean (SD) age of participants was 28.37 (8.20) y. Most were single, satisfied with salary benefits and reported 'good' to 'excellent' relationships at work. The mean (SD) duration of duty hours was 8.12 (0.76) h and 43.6% were attending to more than 4 patients/shift. The mean (SD) perceived stress level was 22.19 (7.17) [Range: 3 to 39]. High compassion satisfaction, high burnout, and high secondary traumatic stress were reported by 25 (19.4%), 30 (23.3%) and 30 (23.3%) nurses respectively. PSS14 was negatively correlated with compassion satisfaction (r = -0.28) and positively correlated with burnout (r = 0.43) and secondary traumatic stress (r = 0.24). Most of the nurses (91, 70.5%) were identified as perceiving moderate to high stress. Professional quality of life domains correlated with perceived stress. There is further need to study domains influencing NICU nurses' professional QOL. Identifying stress and QOL issues in NICU nurses can help formulate relevant policies.

  20. Real-time bilinear rotation decoupling in absorptive mode J-spectroscopy: Detecting low-intensity metabolite peak close to high-intensity metabolite peak with convenience.

    PubMed

    Verma, Ajay; Baishya, Bikash

    2016-05-01

    "Pure shift" NMR spectra display singlet peak per chemical site. Thus, high resolution is offered at the cost of valuable J-coupling information. In the present work, real-time BIRD (BIlinear Rotation Decoupling) is applied to the absorptive-mode 2D J-spectroscopy to provide pure shift spectrum in the direct dimension and J-coupling information in the indirect dimension. Quite often in metabolomics, proton NMR spectra from complex bio-fluids display tremendous signal overlap. Although conventional J-spectroscopy in principle overcomes this problem by separating the multiplet information from chemical shift information, however, only magnitude mode of the experiment is practical, sacrificing much of the potential high resolution that could be achieved. Few J-spectroscopy methods have been reported so far that produce high-resolution pure shift spectrum along with J-coupling information for crowded spectral regions. In the present work, high-quality J-resolved spectrum from important metabolomic mixture such as tissue extract from rat cortex is demonstrated. Many low-intensity metabolite peaks which are obscured by the broad dispersive tails from high-intensity metabolite peaks in regular magnitude mode J-spectrum can be clearly identified in real-time BIRD J-resolved spectrum. The general practice of removing such spectral overlap is tedious and time-consuming as it involves repeated sample preparation to change the pH of the tissue extract sample and subsequent spectra recording. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. The study towards high intensity high charge state laser ion sources.

    PubMed

    Zhao, H Y; Jin, Q Y; Sha, S; Zhang, J J; Li, Z M; Liu, W; Sun, L T; Zhang, X Z; Zhao, H W

    2014-02-01

    As one of the candidate ion sources for a planned project, the High Intensity heavy-ion Accelerator Facility, a laser ion source has been being intensively studied at the Institute of Modern Physics in the past two years. The charge state distributions of ions produced by irradiating a pulsed 3 J/8 ns Nd:YAG laser on solid targets of a wide range of elements (C, Al, Ti, Ni, Ag, Ta, and Pb) were measured with an electrostatic ion analyzer spectrometer, which indicates that highly charged ions could be generated from low-to-medium mass elements with the present laser system, while the charge state distributions for high mass elements were relatively low. The shot-to-shot stability of ion pulses was monitored with a Faraday cup for carbon target. The fluctuations within ±2.5% for the peak current and total charge and ±6% for pulse duration were demonstrated with the present setup of the laser ion source, the suppression of which is still possible.

  2. Light shield and cooling apparatus. [high intensity ultraviolet lamp

    NASA Technical Reports Server (NTRS)

    Meador, T. G., Jr. (Inventor)

    1974-01-01

    A light shield and cooling apparatus was developed for a high intensity ultraviolet lamp including water and high pressure air for cooling and additional apparatus for shielding the light and suppressing the high pressure air noise.

  3. High-quality cardiopulmonary resuscitation.

    PubMed

    Nolan, Jerry P

    2014-06-01

    The quality of cardiopulmonary resuscitation (CPR) impacts on outcome after cardiac arrest. This review will explore the factors that contribute to high-quality CPR and the metrics that can be used to monitor performance. A recent consensus statement from North America defined five key components of high-quality CPR: minimizing interruptions in chest compressions, providing compressions of adequate rate and depth, avoiding leaning on the chest between compressions, and avoiding excessive ventilation. Studies have shown that real-time feedback devices improve the quality of CPR and, in one before-and-after study, outcome from out-of-hospital cardiac arrest. There is evidence for increasing survival rates following out-of-hospital cardiac arrest and this is associated with increasing rates of bystander CPR. The quality of CPR provided by healthcare professionals can be improved with real-time feedback devices. The components of high-quality CPR and the metrics that can be measured and fed back to healthcare professionals have been defined by expert consensus. In the future, real-time feedback based on the physiological responses to CPR may prove more effective.

  4. High-Intensity Sweeteners in Alternative Tobacco Products

    PubMed Central

    Miao, Shida; Beach, Evan S.; Sommer, Toby J.; Zimmerman, Julie B.

    2016-01-01

    Introduction: Sweeteners in tobacco products may influence use initiation and reinforcement, with special appeal to adolescents. Recent analytical studies of smokeless tobacco products (snuff, snus, dissolvables) detected flavorants identical to those added to confectionary products such as hard candy and chewing gum. However, these studies did not determine the levels of sweeteners. The objective of the present study was to quantify added sweeteners in smokeless tobacco products, a dissolvable product, electronic cigarette liquids and to compare with sweetener levels in confectionary products. Methods: Sweetener content of US-sourced smokeless tobacco, electronic cigarette liquid, and confectionary product samples was analyzed by liquid chromatography-electrospray ionization–mass spectrometry (LC-ESI-MS). Results: All smokeless products contained synthetic high intensity sweeteners, with snus and dissolvables exceeding levels in confectionary products (as much as 25-fold). All snus samples contained sucralose and most also aspartame, but no saccharin. In contrast, all moist snuff samples contained saccharin. The dissolvable sample contained sucralose and sorbitol. Ethyl maltol was the most common sweet-associated component in electronic cigarette liquids. Discussion: Sweetener content was dependent on product category, with saccharin in moist snuff, an older category, sucralose added at high levels to more recently introduced products (snus, dissolvable) and ethyl maltol in electronic cigarette liquid. The very high sweetener concentrations may be necessary for the consumer to tolerate the otherwise aversive flavors of tobacco ingredients. Regulation of sweetener levels in smokeless tobacco products may be an effective measure to modify product attractiveness, initiation and use patterns. Implications: Dissolvables, snus and electronic cigarettes have been promoted as risk-mitigation products due to their relatively low content of nitrosamines and other tobacco

  5. Evidence based exercise - clinical benefits of high intensity interval training.

    PubMed

    Shiraev, Tim; Barclay, Gabriella

    2012-12-01

    Aerobic exercise has a marked impact on cardiovascular disease risk. Benefits include improved serum lipid profiles, blood pressure and inflammatory markers as well as reduced risk of stroke, acute coronary syndrome and overall cardiovascular mortality. Most exercise programs prescribed for fat reduction involve continuous, moderate aerobic exercise, as per Australian Heart Foundation clinical guidelines. This article describes the benefits of exercise for patients with cardiovascular and metabolic disease and details the numerous benefits of high intensity interval training (HIIT) in particular. Aerobic exercise has numerous benefits for high-risk populations and such benefits, especially weight loss, are amplified with HIIT. High intensity interval training involves repeatedly exercising at a high intensity for 30 seconds to several minutes, separated by 1-5 minutes of recovery (either no or low intensity exercise). HIT is associated with increased patient compliance and improved cardiovascular and metabolic outcomes and is suitable for implementation in both healthy and 'at risk' populations. Importantly, as some types of exercise are contraindicated in certain patient populations and HIIT is a complex concept for those unfamiliar to exercise, some patients may require specific assessment or instruction before commencing a HIIT program.

  6. Continuous moderate-intensity exercise with or without intermittent high-intensity work: effects on acute and late glycaemia in athletes with Type 1 diabetes mellitus.

    PubMed

    Iscoe, K E; Riddell, M C

    2011-07-01

    Individuals with Type 1 diabetes mellitus are susceptible to hypoglycaemia during and after continuous moderate-intensity exercise, but hyperglycaemia during intermittent high-intensity exercise. The combination of both forms of exercise may have a moderating effect on glycaemia in recovery. The aims of this study were to compare the physiological responses and associated glycaemic changes to continuous moderate-intensity exercise vs. continuous moderate-intensity exercise + intermittent high-intensity exercise in athletes with Type 1 diabetes. Interstitial glucose levels were measured in a blinded fashion in 11 trained athletes with Type 1 diabetes during two sedentary days and during 2 days in which 45 min of afternoon continuous moderate-intensity exercise occurred either with or without intermittent high-intensity exercise. The total amount of work performed and the duration of exercise was identical between sessions. During exercise, heart rate, respiratory exchange ratio, oxygen utilization, ventilation and blood lactate levels were higher during continuous moderate-intensity + intermittent high-intensity exercise vs. continuous moderate-intensity exercise (all P < 0.05). Despite these marked cardiorespiratory differences between trials, there was no difference in the reduction of interstitial glucose or plasma glucose levels between the exercise trials. Nocturnal glucose levels were higher in continuous moderate-intensity + intermittent high-intensity exercise and in sedentary vs. continuous moderate-intensity exercise (P < 0.05). Compared with continuous moderate-intensity exercise alone, continuous moderate-intensity + intermittent high-intensity exercise was associated with less post-exercise hypoglycaemia (5.2 vs. 1.5% of the time spent with glucose < 4.0 mmol/l) and more post-exercise hyperglycaemia (33.8 vs. 20.4% of time > 11.0 mmol/l). Although the decreases in glucose level during continuous moderate-intensity exercise and continuous moderate-intensity

  7. [The future of intensive medicine].

    PubMed

    Palencia Herrejón, E; González Díaz, G; Mancebo Cortés, J

    2011-05-01

    Although Intensive Care Medicine is a young specialty compared with other medical disciplines, it currently plays a key role in the process of care for many patients. Experience has shown that professionals with specific training in Intensive Care Medicine are needed to provide high quality care to critically ill patients. In Europe, important steps have been taken towards the standardization of training programs of the different member states. However, it is now necessary to take one more step forward, that is, the creation of a primary specialty in Intensive Care Medicine. Care of the critically ill needs to be led by specialists who have received specific and complete training and who have the necessary professional competences to provide maximum quality care to their patients. The future of the specialty presents challenges that must be faced with determination, with the main objective of meeting the needs of the population. Copyright © 2011 Elsevier España, S.L. y SEMICYUC. All rights reserved.

  8. High-frequency tone burst-evoked ABR latency-intensity functions.

    PubMed

    Fausti, S A; Olson, D J; Frey, R H; Henry, J A; Schaffer, H I

    1993-01-01

    High-frequency tone burst stimuli (8, 10, 12, and 14 kHz) have been developed and demonstrated to provide reliable and valid auditory brainstem responses (ABRs) in normal-hearing subjects. In this study, latency-intensity functions (LIFs) were determined using these stimuli in 14 normal-hearing individuals. Significant shifts in response latency occurred as a function of stimulus intensity for all tone burst frequencies. For each 10 dB shift in intensity, latency shifts for waves I and V were statistically significant except for one isolated instance. LIF slopes were comparable between frequencies, ranging from 0.020 to 0.030 msec/dB. These normal LIFs for high-frequency tone burst-evoked ABRs suggest the degree of response latency change that might be expected from, for example, progressive hearing loss due to ototoxic insult, although these phenomena may not be directly related.

  9. Free-field propagation of high intensity noise

    NASA Technical Reports Server (NTRS)

    Welz, Joseph P.; Mcdaniel, Oliver H.

    1990-01-01

    Observed spectral data from supersonic jet aircraft are known to contain much more high frequency energy than can be explained by linear acoustic propagation theory. It is believed that the high frequency energy is an effect of nonlinear distortion due to the extremely high acoustic levels generated by the jet engines. The objective, to measure acoustic waveform distortion for spherically diverging high intensity noise, was reached by using an electropneumatic acoustic source capable of generating sound pressure levels in the range of 140 to 160 decibels (re 20 micro Pa). The noise spectrum was shaped to represent the spectra generated by jet engines. Two microphones were used to capture the acoustic pressure waveform at different points along the propagation path in order to provide a direct measure of the waveform distortion as well as spectral distortion. A secondary objective was to determine that the observed distortion is an acoustic effect. To do this an existing computer prediction code that deals with nonlinear acoustic propagation was used on data representative of the measured data. The results clearly demonstrate that high intensity jet noise does shift the energy in the spectrum to the higher frequencies along the propagation path. In addition, the data from the computer model are in good agreement with the measurements, thus demonstrating that the waveform distortion can be accounted for with nonlinear acoustic theory.

  10. Laser imprint suppression using high-Z layers at high foot intensities

    NASA Astrophysics Data System (ADS)

    Karasik, Max; Aglitskiy, Y.; Serlin, V.; Weaver, J. L.; Bates, J. W.; Phillips, L. S.

    2006-10-01

    Laser imprint experiments are carried out on the Nike KrF laser with induced spatial incoherence (ISI) smoothing. Most of the imprint occurs during the initial low-intensity (``foot'') part of the pulse, which is necessary to compress the target to achieve high gain. It has been found previously that a thin high-Z overcoat on the laser side of the target can be effective in suppressing imprint [S. P. Obenschain et al. Phys. Plasmas 9, 2234 (2002)]. The present experiments are designed to extend this method to higher foot intensities (˜10^13 W/cm^2), approaching those of the current high gain pellet designs. Measurements of Raleigh-Taylor (RT) amplified areal mass non-uniformity are made by face-on x-ray radiography using Bragg reflection from a curved crystal coupled to an x-ray streak camera. X-ray flux from the high-Z layer is monitored using absolutely calibrated time-resolved x-ray spectrometers. Simultaneous side-on radiography using a curved crystal allows target trajectory measurement for comparison with simulations. The effect of the high-Z layers of varying thicknesses on ISI imprint as well as re-imposed ripple growth will be presented for two different materials (Au and Pd). This work is supported by US DOE/NNSA.

  11. High-intensity discharge lamp and Duffing oscillator—Similarities and differences

    NASA Astrophysics Data System (ADS)

    Baumann, Bernd; Schwieger, Joerg; Stein, Ulrich; Hallerberg, Sarah; Wolff, Marcus

    2017-12-01

    The processes inside the arc tube of high-intensity discharge lamps are investigated using finite element simulations. The behavior of the gas mixture inside the arc tube is governed by differential equations describing mass, energy, and charge conservation, as well as the Helmholtz equation for the acoustic pressure and the Reynolds equations for the flow driven by buoyancy and Reynolds stresses. The model is highly nonlinear and requires a recursion procedure to account for the impact of acoustic streaming on the temperature and other fields. The investigations reveal the presence of a hysteresis and the corresponding jump phenomenon, quite similar to a Duffing oscillator. The similarities and, in particular, the differences of the nonlinear behavior of the high-intensity discharge lamp to that of a Duffing oscillator are discussed. For large amplitudes, the high-intensity discharge lamp exhibits a stiffening effect in contrast to the Duffing oscillator. It is speculated on how the stiffening might affect hysteresis suppression.

  12. Time evolution of atmospheric particle number concentration during high-intensity pyrotechnic events

    NASA Astrophysics Data System (ADS)

    Crespo, Javier; Yubero, Eduardo; Nicolás, Jose F.; Caballero, Sandra; Galindo, Nuria

    2014-10-01

    The Mascletàs are high-intensity pyrotechnic events, typical of eastern Spanish festivals, in which thousands of firecrackers are burnt at ground level in an intense, short-time (<8 min) deafening spectacle that generates short-lived, thick aerosol clouds. In this study, the impact of such events on air quality has been evaluated by means of particle number concentration measurements performed close to the venue during the June festival in Alicante (southeastern Spain). Peak concentrations and dilution times observed throughout the Mascletàs have been compared to those measured when conventional aerial fireworks were launched 2 km away from the monitoring site. The impact of the Mascletàs on the total number concentration of particles larger than 0.3 μm was higher (maximum ∼2·104 cm-3) than that of fireworks (maximum ∼2·103 cm-3). The effect of fireworks depended on whether the dominant meteorological conditions favoured the transport of the plume to the measurement location. However, the time required for particle concentrations to return to background levels is longer and more variable for firework displays (minutes to hours) than for the Mascletàs (<25 min).

  13. An improved multi-exposure approach for high quality holographic femtosecond laser patterning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Chenchu; Hu, Yanlei, E-mail: huyl@ustc.edu.cn, E-mail: jwl@ustc.edu.cn; Li, Jiawen, E-mail: huyl@ustc.edu.cn, E-mail: jwl@ustc.edu.cn

    High efficiency two photon polymerization through single exposure via spatial light modulator (SLM) has been used to decrease the fabrication time and rapidly realize various micro/nanostructures, but the surface quality remains a big problem due to the speckle noise of optical intensity distribution at the defocused plane. Here, a multi-exposure approach which used tens of computer generate holograms successively loaded on SLM is presented to significantly improve the optical uniformity without losing efficiency. By applying multi-exposure, we found that the uniformity at the defocused plane was increased from ∼0.02 to ∼0.6 according to our simulation. The fabricated two series ofmore » letters “HELLO” and “USTC” under single-and multi-exposure in our experiment also verified that the surface quality was greatly improved. Moreover, by this method, several kinds of beam splitters with high quality, e.g., 2 × 2, 5 × 5 Daman, and complex nonseperate 5 × 5, gratings were fabricated with both of high quality and short time (<1 min, 95% time-saving). This multi-exposure SLM-two-photon polymerization method showed the promising prospect in rapidly fabricating and integrating various binary optical devices and their systems.« less

  14. Guiding of High Laser Intensities in Long Plasma Channels

    NASA Astrophysics Data System (ADS)

    Levin, M.; Eisenmann, S.; Palchan, T.; Zigler, A.; Sugiyama, K.; Nakajima, K.; Kaganovich, D.; Hubbard, R. F.; Ting, A.; Gordon, D. F.; Sprangle, P.; Fraenkel, M.; Maman, S.; Henis, Z.

    Plasma channels have been widely used to guide intense laser pulses over many Rayleigh lengths. Using optimized segmented capillary discharges, we demonstrated guided propagation of ultra short (100 fs) high intensity (1016 W/cm-2, limited by the laser system) pulses over distances up to 12.6 cm and intensities above 1018W/cm2 for 1.5cm boron nitride capillary. Both radial and longitudinal density profiles of plasma channels were studied under various discharge conditions. A new diagnostic technique is presented in which the transport of a guided laser pulse at different delay times from the initiation of the discharge is sampled on a single discharge shot. Using external, 10 nsec Nd YAG laser of several tenths of milijoules to ignite polyethylene capillaries we have demonstrated channels of various length in density range of 1017 - 1019 cm-3 and up to 25% deep. The longitudinal profiles were found to be remarkably uniform in both short and long capillaries. The Boron Nitride capillary has provided a guiding medium that can withstand more than 1000 shots. Using these capillaries we have guided laser intensities above 1018W/cm2. The laser ignition of capillary discharge provided reliable almost jitter free approach. The concerns related to influence of relatively high current density flow through capillary on the injected electrons were studied extensively by us both theoretically and experimentally using a simple injection method. The method is based on the interaction of a high intensity laser pulse with a thin wire placed near capillary entrance. The influence of magnetic fields was found to be insignificant. Using this method we have studied transport of electrons though capillary discharge.

  15. Non-thermal High-intensity Focused Ultrasound for Breast Cancer Therapy

    DTIC Science & Technology

    2012-07-01

    AD ________________ Award Number: W81XWH-11-1-0341 TITLE: Non-thermal high-intensity focused ultrasound for breast cancer therapy PRINCIPAL...30 Jun 2012 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Non-thermal high-intensity focused ultrasound for breast cancer therapy 5b. GRANT NUMBER W81XWH...the in vivo animal experiments. However, the tasks planned for the animal studies were not completed due to the delayed approval of the animal

  16. Prevalence and quality of clinical pathways in Swedish intensive care units: a national survey.

    PubMed

    Bjurling-Sjöberg, Petronella; Jansson, Inger; Wadensten, Barbro; Engström, Gabriella; Pöder, Ulrika

    2014-02-01

    To identify the prevalence of clinical pathways (CPs) in Swedish intensive care units (ICUs) and to explore the quality, content and evidence base of the documents. A descriptive and explorative survey of all Swedish ICUs (N84) and a review of submitted examples of CPs (n12) were conducted. CPs were in use at 20% of the Swedish ICUs. There was a significant geographic variation but no relationship between the use of CPs and category of hospital, type of ICU, size of ICU or type of health record applied. In total, 56 CPs were reported within a range of scopes and extensions. The content of the ICUs' CPs, as well as the degree to which they were interprofessional, evidence based, and renewed varied. Progress has been made in relation to CPs in recent years, but there is potential for further improvements. None of the ICUs had CPs that contained all key characteristics of a high-quality, interprofessional and evidence-based CP identified in the literature. Greater knowledge sharing and cooperation within the field would be beneficial, and further research is needed. © 2013 John Wiley & Sons, Ltd.

  17. High-Intensity Sweeteners in Alternative Tobacco Products.

    PubMed

    Miao, Shida; Beach, Evan S; Sommer, Toby J; Zimmerman, Julie B; Jordt, Sven-Eric

    2016-11-01

    Sweeteners in tobacco products may influence use initiation and reinforcement, with special appeal to adolescents. Recent analytical studies of smokeless tobacco products (snuff, snus, dissolvables) detected flavorants identical to those added to confectionary products such as hard candy and chewing gum. However, these studies did not determine the levels of sweeteners. The objective of the present study was to quantify added sweeteners in smokeless tobacco products, a dissolvable product, electronic cigarette liquids and to compare with sweetener levels in confectionary products. Sweetener content of US-sourced smokeless tobacco, electronic cigarette liquid, and confectionary product samples was analyzed by liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS). All smokeless products contained synthetic high intensity sweeteners, with snus and dissolvables exceeding levels in confectionary products (as much as 25-fold). All snus samples contained sucralose and most also aspartame, but no saccharin. In contrast, all moist snuff samples contained saccharin. The dissolvable sample contained sucralose and sorbitol. Ethyl maltol was the most common sweet-associated component in electronic cigarette liquids. Sweetener content was dependent on product category, with saccharin in moist snuff, an older category, sucralose added at high levels to more recently introduced products (snus, dissolvable) and ethyl maltol in electronic cigarette liquid. The very high sweetener concentrations may be necessary for the consumer to tolerate the otherwise aversive flavors of tobacco ingredients. Regulation of sweetener levels in smokeless tobacco products may be an effective measure to modify product attractiveness, initiation and use patterns. Dissolvables, snus and electronic cigarettes have been promoted as risk-mitigation products due to their relatively low content of nitrosamines and other tobacco toxicants. This study is the first to quantify high

  18. Nonlinear behavior in high-intensity discharge lamps

    NASA Astrophysics Data System (ADS)

    Baumann, Bernd; Schwieger, Joerg; Wolff, Marcus; Manders, Freddy; Suijker, Jos

    2016-06-01

    The light flicker problem of high intensity discharge lamps is studied numerically and experimentally. It is shown that in some respects the systems behave very similar to the forced Duffing oscillator with a softening spring. In particular, the jump phenomenon and hysteresis are observed in the simulations and in the experiments.

  19. High-intensity erotic visual stimuli de-activate the primary visual cortex in women.

    PubMed

    Huynh, Hieu K; Beers, Caroline; Willemsen, Antoon; Lont, Erna; Laan, Ellen; Dierckx, Rudi; Jansen, Monique; Sand, Michael; Weijmar Schultz, Willibrord; Holstege, Gert

    2012-06-01

    The primary visual cortex, Brodmann's area (BA 17), plays a vital role in basic survival mechanisms in humans. In most neuro-imaging studies in which the volunteers have to watch pictures or movies, the primary visual cortex is similarly activated independent of the content of the pictures or movies. However, in case the volunteers perform demanding non-visual tasks, the primary visual cortex becomes de-activated, although the amount of incoming visual sensory information is the same. Do low- and high-intensity erotic movies, compared to neutral movies, produce similar de-activation of the primary visual cortex? Brain activation/de-activation was studied by Positron Emission Tomography scanning of the brains of 12 healthy heterosexual premenopausal women, aged 18-47, who watched neutral, low- and high-intensity erotic film segments. We measured differences in regional cerebral blood flow (rCBF) in the primary visual cortex during watching neutral, low-intensity erotic, and high-intensity erotic film segments. Watching high-intensity erotic, but not low-intensity erotic movies, compared to neutral movies resulted in strong de-activation of the primary (BA 17) and adjoining parts of the secondary visual cortex. The strong de-activation during watching high-intensity erotic film might represent compensation for the increased blood supply in the brain regions involved in sexual arousal, also because high-intensity erotic movies do not require precise scanning of the visual field, because the impact is clear to the observer. © 2012 International Society for Sexual Medicine.

  20. High-intensity interval running is perceived to be more enjoyable than moderate-intensity continuous exercise: implications for exercise adherence.

    PubMed

    Bartlett, Jonathan D; Close, Graeme L; MacLaren, Don P M; Gregson, Warren; Drust, Barry; Morton, James P

    2011-03-01

    The aim of this study was to objectively quantify ratings of perceived enjoyment using the Physical Activity Enjoyment Scale following high-intensity interval running versus moderate-intensity continuous running. Eight recreationally active men performed two running protocols consisting of high-intensity interval running (6 × 3 min at 90% VO(2max) interspersed with 6 × 3 min active recovery at 50% VO(2max) with a 7-min warm-up and cool down at 70% VO(2max)) or 50 min moderate-intensity continuous running at 70% VO(2max). Ratings of perceived enjoyment after exercise were higher (P < 0.05) following interval running compared with continuous running (88 ± 6 vs. 61 ± 12) despite higher (P < 0.05) ratings of perceived exertion (14 ± 1 vs. 13 ± 1). There was no difference (P < 0.05) in average heart rate (88 ± 3 vs. 87 ± 3% maximum heart rate), average VO(2) (71 ± 6 vs. 73 ± 4%VO(2max)), total VO(2) (162 ± 16 vs. 166 ± 27 L) or energy expenditure (811 ± 83 vs. 832 ± 136 kcal) between protocols. The greater enjoyment associated with high-intensity interval running may be relevant for improving exercise adherence, since running is a low-cost exercise intervention requiring no exercise equipment and similar relative exercise intensities have previously induced health benefits in patient populations.

  1. A patient survey of sleep quality in the Intensive Care Unit.

    PubMed

    Little, A; Ethier, C; Ayas, N; Thanachayanont, T; Jiang, D; Mehta, S

    2012-04-01

    Patients in the Intensive Care Unit (ICU) experience qualitative and quantitative sleep disruption leading to sleep deprivation and adverse sequelae. Patient-related factors, environmental factors, and health-support techniques contribute to sleep disruption. This quality improvement study examines potential factors contributing to poor sleep in the ICU. Medical and surgical patients who spent at least one night in one of two academic Canadian ICUs were asked to complete a questionnaire that explored quality and quantity of sleep, factors contributing to poor sleep, and suggested modifications to improve sleep in the ICU. Patient demographics as well as admission data were recorded. Study population was 116 patients (63 M:53 F). Mean age was 55.5 ± 18.1 years and APACHE II score 16.0 ± 7.9. 45.7% were mechanically ventilated, and 68.9% received intravenous sedatives and/or analgesics. Sleep quality in the ICU was rated as poor/very poor by 59% of patients compared to 24% at home; the 5 most frequently cited reasons for this were noise, pain, light, loud talking, and intravenous catheters. Patients suggested the following nocturnal modifications: closing doors/blinds, no unnecessary interruptions, sleeping pills, and dimmed lights. No significant correlations were found between perceived sleep quality and illness severity or mechanical ventilation. Patients who received intravenous sedatives reported better sleep quality (P<0.01). Patients commonly report poor sleep in the ICU related to environmental factors that are potentially modifiable.

  2. The relationship between thermal comfort and light intensity with sleep quality and eye tiredness in shift work nurses.

    PubMed

    Azmoon, Hiva; Dehghan, Habibollah; Akbari, Jafar; Souri, Shiva

    2013-01-01

    Environmental conditions such as lighting and thermal comfort are influencing factors on sleep quality and visual tiredness. The purpose of this study was the determination of the relationship between thermal comfort and light intensity with the sleep quality and eye fatigue in shift nurses. This cross-sectional research was conducted on 82 shift-work personnel of 18 nursing workstations in Isfahan Al-Zahra Hospital, Iran, in 2012. Heat stress monitoring (WBGT) and photometer (Hagner Model) were used for measuring the thermal conditions and illumination intensity, respectively. To measure the sleep quality, visual tiredness, and thermal comfort, Pittsburg sleep quality index, eye fatigue questionnaire, and thermal comfort questionnaire were used, respectively. The data were analyzed with descriptive statistics, Student's t-test, and Pearson correlation. Correlation between thermal comfort which was perceived from the self-reporting of people with eye tiredness was -0.38 (P = 0.002). Pearson correlation between thermal comfort and sleep quality showed a positive and direct relationship (r = 0.241, P = 0.33) but the correlation between thermal comfort, which was perceived from the self-reporting of shift nurses, and WBGT index was a weak relationship (r = 0.019). Based on the obtained findings, it can be concluded that a defect in environmental conditions such as thermal conditions and light intensity and also lack of appropriate managerial plan for night shift-work nurses are destructive and negative factors for the physical and mental health of this group of practitioners.

  3. The Relationship between Thermal Comfort and Light Intensity with Sleep Quality and Eye Tiredness in Shift Work Nurses

    PubMed Central

    Azmoon, Hiva; Dehghan, Habibollah; Akbari, Jafar; Souri, Shiva

    2013-01-01

    Environmental conditions such as lighting and thermal comfort are influencing factors on sleep quality and visual tiredness. The purpose of this study was the determination of the relationship between thermal comfort and light intensity with the sleep quality and eye fatigue in shift nurses. Method. This cross-sectional research was conducted on 82 shift-work personnel of 18 nursing workstations in Isfahan Al-Zahra Hospital, Iran, in 2012. Heat stress monitoring (WBGT) and photometer (Hagner Model) were used for measuring the thermal conditions and illumination intensity, respectively. To measure the sleep quality, visual tiredness, and thermal comfort, Pittsburg sleep quality index, eye fatigue questionnaire, and thermal comfort questionnaire were used, respectively. The data were analyzed with descriptive statistics, Student's t-test, and Pearson correlation. Results. Correlation between thermal comfort which was perceived from the self-reporting of people with eye tiredness was −0.38 (P = 0.002). Pearson correlation between thermal comfort and sleep quality showed a positive and direct relationship (r = 0.241, P = 0.33) but the correlation between thermal comfort, which was perceived from the self-reporting of shift nurses, and WBGT index was a weak relationship (r = 0.019). Conclusion. Based on the obtained findings, it can be concluded that a defect in environmental conditions such as thermal conditions and light intensity and also lack of appropriate managerial plan for night shift-work nurses are destructive and negative factors for the physical and mental health of this group of practitioners. PMID:23476674

  4. Multimodal Therapy Involving High-Intensity Interval Training Improves the Physical Fitness, Motor Skills, Social Behavior, and Quality of Life of Boys With ADHD: A Randomized Controlled Study.

    PubMed

    Meßler, Carolin Friederike; Holmberg, Hans-Christer; Sperlich, Billy

    2018-06-01

    To compare the effects of multimodal therapy including supervised high-intensity interval training (HIIT) with those of standard multimodal therapy (TRAD) concerning key variables of physical fitness (peak power and oxygen uptake), motor skills, social behavior, and quality of life in boys with ADHD. A single-center, two-arm randomized, controlled design was used, with 28 boys (8-13 years of age, IQ = 83-136) being randomly assigned to multimodal HIIT (three sessions/week, 4 × 4-min intervals at 95% of peak heart rate) or TRAD. The Movement Assessment Battery for Children II evaluated motor skills and the German version of the hyperkinetic disorder questionnaire for external evaluation by the guardians (FBB-HKS) or German version of the hyperkinetic disorder questionnaire for self-assessment by the children (SBB-HKS) and the KINDL-R questionnaires mental health and health-related quality of life. Both interventions enhanced peak power, and HIIT also reduced submaximal oxygen uptake. HIIT was more effective than TRAD in improving the total score for motor skills (including manual dexterity and ball skills; p < .05), self-esteem, friends, and competence ( p < .05) and, moreover, improved subjective ratings of attention. Three weeks of multimodal therapy including HIIT improved physical fitness, motor skills, certain aspects of quality of life, competence, and attention in boys with ADHD.

  5. Prediction of Quality of life by Self-Efficacy, Pain Intensity and Pain Duration in Patient with Pain Disorders

    PubMed Central

    Yazdi-Ravandi, Saeid; Taslimi, Zahra; Jamshidian, Narges; Saberi, Hayede; Shams, Jamal; Haghparast, Abbas

    2013-01-01

    The quality of life (QOL) has been defined as “a person's sense of well-being that stems from satisfaction or dissatisfaction with the areas of life that are important to him/her”. It is generally accepted that pain intensity and duration have a negative impact on the QOL. One specific type of control is “self-efficacy”, or the belief that one has the ability to successfully engage in specific actions. The ability to adapt to pain may play an important role in maintaining the QOL. In this study, we investigated the role of self-efficacy, pain intensity, and pain duration in various domains of quality of life such as physical, psychological, social and environmental domains. In this study, 290 adult patients (146 men, 144 women) completed coping self-efficacy and the WHOQOL-BREF Questionnaire. Moreover, we illustrated numerical rating scale for pain intensity. The results were analyzed using SPSS version of 19.0 and means, descriptive correlation, and regression were calculated. Our data revealed that self-efficacy but not the pain duration could significantly anticipate the QOL and its four related domains (P<0.001). In addition, it is noticeable that the effect of self-efficacy on the prediction of QOL is much more obvious in the psychological domain. However, the pain intensity could predict all of the QOL domains (P<0.001) except social and environmental ones. In conclusion, to predict the quality of life (QOL) in person suffering from chronic pain, self-efficacy and pain intensity are more important factors than the pain duration and demographic variables. PMID:25337337

  6. The bidirectional relationship between pain intensity and sleep disturbance/quality in patients with low back pain.

    PubMed

    Alsaadi, Saad M; McAuley, James H; Hush, Julia M; Lo, Serigne; Bartlett, Delwyn J; Grunstein, Roland R; Maher, Chris G

    2014-09-01

    This study investigated the bidirectional relationship between the intensity of low back pain (LBP) and sleep disturbance. Further, the study aimed to determine whether any relationship is dependent on pain duration, symptoms of depression and anxiety, and the method of sleep assessment (subjective vs. objective). Eighty patients with LBP completed a sleep diary. A subgroup of 50 patients additionally wore an electronic device (Armband) to measure sleep for 7 consecutive days. Pain intensity was assessed twice daily using a sleep diary. Depression and anxiety symptoms were assessed at baseline using the Depression Anxiety Stress Scale questionnaire. Generalized estimating equations (GEE) with an exchangeable correlation structure were used to examine the relationship between day-time pain intensity and sleep. The GEE analysis showed that a night of poor sleep quality, difficulty falling sleep (assessed by the sleep diary), waking after sleep onset, and low sleep efficiency (assessed by the sleep diary and Armband) were followed by a day with higher pain intensity. Further, a day with higher pain intensity was associated with a decrease in the subsequent night's sleep quality, an increase in sleep latency (assessed by the sleep diary), waking after sleep onset (assessed by both measures), and low sleep efficiency (assessed by the Armband). The findings demonstrate that there is a bidirectional relationship between sleep and pain intensity in patients with LBP. The relationship is independent of pain duration and baseline symptoms of depression and anxiety and somewhat dependent on the method of sleep measurement (sleep diary or Armband). Future research is needed to determine whether targeting sleep improvement in patients with LBP contributes to pain reduction.

  7. 14 CFR 29.1317 - High-intensity Radiated Fields (HIRF) Protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false High-intensity Radiated Fields (HIRF...-intensity Radiated Fields (HIRF) Protection. (a) Except as provided in paragraph (d) of this section, each electrical and electronic system that performs a function whose failure would prevent the continued safe...

  8. 14 CFR 25.1317 - High-intensity Radiated Fields (HIRF) Protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false High-intensity Radiated Fields (HIRF...-intensity Radiated Fields (HIRF) Protection. (a) Except as provided in paragraph (d) of this section, each electrical and electronic system that performs a function whose failure would prevent the continued safe...

  9. 14 CFR 27.1317 - High-intensity Radiated Fields (HIRF) Protection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false High-intensity Radiated Fields (HIRF...-intensity Radiated Fields (HIRF) Protection. (a) Except as provided in paragraph (d) of this section, each electrical and electronic system that performs a function whose failure would prevent the continued safe...

  10. 14 CFR 27.1317 - High-intensity Radiated Fields (HIRF) Protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false High-intensity Radiated Fields (HIRF...-intensity Radiated Fields (HIRF) Protection. (a) Except as provided in paragraph (d) of this section, each electrical and electronic system that performs a function whose failure would prevent the continued safe...

  11. 14 CFR 25.1317 - High-intensity Radiated Fields (HIRF) Protection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false High-intensity Radiated Fields (HIRF...-intensity Radiated Fields (HIRF) Protection. (a) Except as provided in paragraph (d) of this section, each electrical and electronic system that performs a function whose failure would prevent the continued safe...

  12. 14 CFR 29.1317 - High-intensity Radiated Fields (HIRF) Protection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false High-intensity Radiated Fields (HIRF...-intensity Radiated Fields (HIRF) Protection. (a) Except as provided in paragraph (d) of this section, each electrical and electronic system that performs a function whose failure would prevent the continued safe...

  13. An Intense Excitation Source for High Power (Blue-Green) Laser.

    DTIC Science & Technology

    1983-11-22

    mild and forms plasma rings near the edges of the center holes as indicated by the circular line in Figure 1. For dye laser pumping, the high pressure... ring formation, and the heavy gas plasmas produce more high-intensity light pulses than light gas. It is also possible to adjust the diameter of plasma ...sheets into the center hole; 5. the formation of plasma rings ; 6. the expansion and radiative cooling of the plasma which results in 7. the intense

  14. High-intensity interval training and athletic performance in Taekwondo athletes.

    PubMed

    Monks, Lynne; Seo, Myong-Won; Kim, Hyun-Bae; Jung, Hyun C; Song, Jong K

    2017-10-01

    The purpose of this study was to determine the effects of high-intensity interval training (HIIT) on athletic performance in Taekwondo athletes. Thirty-three male and female collegiate Taekwondo athletes were randomly divided into a HIIT group (N.=16) or a high-intensity continuous running (HICR) group (N.=17). The HIIT group undertook training of high-intensity sprints interspersed with active rest periods whilst the HICR group participated in high-intensity running for a continuous period. Both groups completed 11 sessions over 4 weeks. Physique, body composition, Wingate anaerobic test and VO2max test were measured. The vertical jump test, agility T-test and sit-ups were used to assess physical fitness. Repeated measures ANCOVAs with sex as a covariate were applied and significant level was set at 0.05. Following 11 sessions of training, significant improvements in anaerobic peak power (P<0.05), relative peak power (P<0.05), and mean power (P<0.05) were observed only in HIIT group compared to HICR group. A greater improvement of aerobic capacity was observed in HIIT group (8.8%) compared to the HICR group (1.7%). In relation to physical fitness, the HIIT group improved in the vertical jump while the HICR group did not change. Both the HIIT and HICR groups showed greater improvements in T-test and sit-ups during the intervention period. This study shows the effectiveness of eleven sessions of HIIT in producing significant improvements in anaerobic capacity relevant to successful Taekwondo competition performance in collegiate Taekwondo athletes. This could inform the future planning of Taekwondo athletes' pre-competition training, specifically the influence of training intensity on anaerobic capacity.

  15. High-intensity interval exercise training before abdominal aortic aneurysm repair (HIT-AAA): protocol for a randomised controlled feasibility trial.

    PubMed

    Tew, Garry A; Weston, Matthew; Kothmann, Elke; Batterham, Alan M; Gray, Joanne; Kerr, Karen; Martin, Denis; Nawaz, Shah; Yates, David; Danjoux, Gerard

    2014-01-10

    In patients with large abdominal aortic aneurysm (AAA), open surgical or endovascular aneurysm repair procedures are often used to minimise the risk of aneurysm-related rupture and death; however, aneurysm repair itself carries a high risk. Low cardiopulmonary fitness is associated with an increased risk of early post-operative complications and death following elective AAA repair. Therefore, fitness should be enhanced before aneurysm repair. High-intensity interval exercise training (HIT) is a potent, time-efficient strategy for enhancing cardiopulmonary fitness. Here, we describe a feasibility study for a definitive trial of a pre-operative HIT intervention to improve post-operative outcomes in patients undergoing elective AAA repair. A minimum of 50 patients awaiting elective repair of a 5.5-7.0 cm infrarenal AAA will be allocated by minimisation to HIT or usual care control in a 1:1 ratio. The patients allocated to HIT will complete three hospital-based exercise sessions per week, for 4 weeks. Each session will include 2 or 4 min of high-intensity stationary cycling followed by the same duration of easy cycling or passive recovery, repeated until a total of 16 min of high-intensity exercise is accumulated. Outcomes to be assessed before randomisation and 24-48 h before aneurysm repair include cardiopulmonary fitness, maximum AAA diameter and health-related quality of life. In the post-operative period, we will record destination (ward or critical care unit), organ-specific morbidity, mortality and the durations of critical care and hospital stay. Twelve weeks after the discharge, participants will be interviewed to reassess quality of life and determine post-discharge healthcare utilisation. The costs associated with the exercise intervention and healthcare utilisation will be calculated. Ethics approval was secured through Sunderland Research Ethics Committee. The findings of the trial will be disseminated through peer-reviewed journals, and national and

  16. Multisite evaluation of environmental cleanliness of high-touch surfaces in intensive care unit patient rooms.

    PubMed

    Hopman, Joost; Donskey, Curtis J; Boszczowski, Icaro; Alfa, Michelle J

    2018-05-23

    The efficacy of discharge cleaning and disinfection of high-touch surfaces of intensive care unit patient rooms in Brazil, Canada, the Netherlands, and the United States was evaluated and the effect of an educational intervention was determined. Significant site-to-site differences in cleaning regimens and baseline cleanliness levels were observed using ATP levels, colony-forming units, and reflective surface marker removal percent pass rates. An educational intervention that includes rapid feedback of the ATP measurements could significantly improve the quality of the cleaning and disinfection regimens. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. All rights reserved.

  17. Characterisation of a MeV Bremsstrahlung x-ray source produced from a high intensity laser for high areal density object radiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Courtois, C.; Compant La Fontaine, A.; Bazzoli, S.

    2013-08-15

    Results of an experiment to characterise a MeV Bremsstrahlung x-ray emission created by a short (<10 ps) pulse, high intensity (1.4 × 10{sup 19} W/cm{sup 2}) laser are presented. X-ray emission is characterized using several diagnostics; nuclear activation measurements, a calibrated hard x-ray spectrometer, and dosimeters. Results from the reconstructed x-ray energy spectra are consistent with numerical simulations using the PIC and Monte Carlo codes between 0.3 and 30 MeV. The intense Bremsstrahlung x-ray source is used to radiograph an image quality indicator (IQI) heavily filtered with thick tungsten absorbers. Observations suggest that internal features of the IQI can bemore » resolved up to an external areal density of 85 g/cm{sup 2}. The x-ray source size, inferred by the radiography of a thick resolution grid, is estimated to be approximately 400 μm (full width half maximum of the x-ray source Point Spread Function)« less

  18. [Quality management is associated with high quality services in health care].

    PubMed

    Nielsen, Tenna Hassert; Riis, Allan; Mainz, Jan; Jensen, Anne-Louise Degn

    2013-12-09

    In these years, quality management has been the focus in order to meet high quality services for the patients in Danish health care. This article provides information on quality management and quality improvement and it evaluates its effectiveness in achieving better organizational structures, processes and results in Danish health-care organizations. Our findings generally support that quality management is associated with high quality services in health care.

  19. Compton spectra of atoms at high x-ray intensity

    NASA Astrophysics Data System (ADS)

    Son, Sang-Kil; Geffert, Otfried; Santra, Robin

    2017-03-01

    Compton scattering is the nonresonant inelastic scattering of an x-ray photon by an electron and has been used to probe the electron momentum distribution in gas-phase and condensed-matter samples. In the low x-ray intensity regime, Compton scattering from atoms dominantly comes from bound electrons in neutral atoms, neglecting contributions from bound electrons in ions and free (ionized) electrons. In contrast, in the high x-ray intensity regime, the sample experiences severe ionization via x-ray multiphoton multiple ionization dynamics. Thus, it becomes necessary to take into account all the contributions to the Compton scattering signal when atoms are exposed to high-intensity x-ray pulses provided by x-ray free-electron lasers (XFELs). In this paper, we investigate the Compton spectra of atoms at high x-ray intensity, using an extension of the integrated x-ray atomic physics toolkit, xatom. As the x-ray fluence increases, there is a significant contribution from ionized electrons to the Compton spectra, which gives rise to strong deviations from the Compton spectra of neutral atoms. The present study provides not only understanding of the fundamental XFEL-matter interaction but also crucial information for single-particle imaging experiments, where Compton scattering is no longer negligible. , which features invited work from the best early-career researchers working within the scope of J. Phys. B. This project is part of the Journal of Physics series’ 50th anniversary celebrations in 2017. Sang-Kil Son was selected by the Editorial Board of J. Phys. B as an Emerging Leader.

  20. High-quality digital color xerography

    NASA Astrophysics Data System (ADS)

    Takiguchi, Koichi

    1993-06-01

    Image noise, tone reproduction, color reproduction, fine line reproduction, and OHP performance are the most important characteristics for a high quality color copier. Technologies enabling such quality are use of fine toner, halftone algorithm to ensure good highlight reproduction, soft roll fuser with good release performance, smooth surface and high thermal conductivity, white and smooth paper, and selection of a coating material for the surface layer of the OHP sheets. These technologies are integrated in the Fuji Xerox `A- Color' product. Utilizing 7 micrometers color toner, `A-Color' can make very high quality color copies.

  1. Water-quality response to a high-elevation wildfire in the Colorado Front Range

    USGS Publications Warehouse

    Mast, M. Alisa; Murphy, Sheila F.; Clow, David W.; Penn, Colin A.; Sexstone, Graham A.

    2016-01-01

    Water quality of the Big Thompson River in the Front Range of Colorado was studied for 2 years following a high-elevation wildfire that started in October 2012 and burned 15% of the watershed. A combination of fixed-interval sampling and continuous water-quality monitors was used to examine the timing and magnitude of water-quality changes caused by the wildfire. Prefire water quality was well characterized because the site has been monitored at least monthly since the early 2000s. Major ions and nitrate showed the largest changes in concentrations; major ion increases were greatest in the first postfire snowmelt period, but nitrate increases were greatest in the second snowmelt period. The delay in nitrate release until the second snowmelt season likely reflected a combination of factors including fire timing, hydrologic regime, and rates of nitrogen transformations. Despite the small size of the fire, annual yields of dissolved constituents from the watershed increased 20–52% in the first 2 years following the fire. Turbidity data from the continuous sensor indicated high-intensity summer rain storms had a much greater effect on sediment transport compared to snowmelt. High-frequency sensor data also revealed that weekly sampling missed the concentration peak during snowmelt and short-duration spikes during rain events, underscoring the challenge of characterizing postfire water-quality response with fixed-interval sampling.

  2. Quality of Sleep Among Intensive Care Unit Patients: A Literature Review.

    PubMed

    Bani Younis, Mohammad; Hayajneh, Ferial A

    Investigating sleep disturbances among intensive care unit (ICU) patients and its serious consequences is considered a crucial issue for nurses. The need of sleep increases during hospitalization time to preserve energy for the healing process. Previous studies have demonstrated that sleep disturbance is one of the most common complaints of patients in the ICUs, with a prevalence of more than 50%. Although the total sleep time might be normal, the patients' sleep is fragmented and light in the intensive care settings. The main purpose of this review is to generate a clear view of what is known about sleep disturbances among ICU patients as well as to identify the gap in knowledge regarding this issue. This was done by describing, summarizing, clarifying, and evaluating well-selected previous studies about this topic. In addition, this concise review has focused on the prevalence of sleep disturbances in the ICU, factors contributing to poor quality of sleep among ICU patients, and the physiological effects of poor sleep on the patients' prognosis.

  3. To Change the Things I Can: Making Instruction More Intensive

    ERIC Educational Resources Information Center

    Stevenson, Nathan A.; Reed, Deborah K.

    2017-01-01

    When students do not respond adequately to core instruction, teachers must provide instruction and intervention that is more intensive and, therefore, more effective. However, for many educators, it is often unclear what it means to intensify instruction and how intensive instruction differs from high-quality core instruction. This article…

  4. High intensity single bunch operation with heavy periodic transient beam loading in wide band rf cavities

    NASA Astrophysics Data System (ADS)

    Tamura, Fumihiko; Hotchi, Hideaki; Schnase, Alexander; Yoshii, Masahito; Yamamoto, Masanobu; Ohmori, Chihiro; Nomura, Masahiro; Toda, Makoto; Shimada, Taihei; Hasegawa, Katsushi; Hara, Keigo

    2015-09-01

    The rapid cycling synchrotron (RCS) in the Japan Proton Accelerator Research Complex (J-PARC) was originally designed to accelerate two high intensity bunches, while some of neutron experiments in the materials and life science experimental facility and a muon experiment using main ring beams require a single bunch operation mode, in which one of the two rf buckets is filled and the other is empty. The beam intensity in the single bunch operation has been limited by longitudinal beam losses due to the rf bucket distortions by the wake voltage of the odd harmonics (h =1 ,3 ,5 ) in the wide band magnetic alloy cavities. We installed an additional rf feedforward system to compensate the wake voltages of the odd harmonics (h =1 ,3 ,5 ). The additional system has a similar structure as the existing feedforward system for the even harmonics (h =2 ,4 ,6 ). We describe the function of the feedforward system for the odd harmonics, the commissioning methodology, and the commissioning results. The longitudinal beam losses during the single bunch acceleration disappeared with feedforward for the odd harmonics. We also confirmed that the beam quality in the single bunch acceleration are similar to that of the normal operation with two bunches. Thus, high intensity single bunch acceleration at the intensity of 2.3 ×1013 protons per bunch has been achieved in the J-PARC RCS. This article is a follow-up of our previous article, Phys. Rev. ST Accel. Beams 14, 051004 (2011). The feedforward system extension for single bunch operation was successful.

  5. High-Intensity Focused Ultrasound Therapy: an Overview for Radiologists

    PubMed Central

    Kim, Young-sun; Choi, Min Joo; Lim, Hyo Keun; Choi, Dongil

    2008-01-01

    High-intensity focused ultrasound therapy is a novel, emerging, therapeutic modality that uses ultrasound waves, propagated through tissue media, as carriers of energy. This completely non-invasive technology has great potential for tumor ablation as well as hemostasis, thrombolysis and targeted drug/gene delivery. However, the application of this technology still has many drawbacks. It is expected that current obstacles to implementation will be resolved in the near future. In this review, we provide an overview of high-intensity focused ultrasound therapy from the basic physics to recent clinical studies with an interventional radiologist's perspective for the purpose of improving the general understanding of this cutting-edge technology as well as speculating on future developments. PMID:18682666

  6. Relative Match Intensities at High Altitude in Highly-Trained Young Soccer Players (ISA3600).

    PubMed

    Buchheit, Martin; Hammond, Kristal; Bourdon, Pitre C; Simpson, Ben M; Garvican-Lewis, Laura A; Schmidt, Walter F; Gore, Christopher J; Aughey, Robert J

    2015-03-01

    To compare relative match intensities of sea-level versus high-altitude native soccer players during a 2-week camp at 3600 m, data from 7 sea-level (Australian U17 National team, AUS) and 6 high-altitude (a Bolivian U18 team, BOL) native soccer players were analysed. Two matches were played at sea-level and three at 3600 m on Days 1, 6 and 13. The Yo-Yo Intermittent recovery test (vYo-YoIR1) was performed at sea-level, and on Days 3 and 10. Match activity profiles were measured via 10-Hz GPS. Distance covered >14.4 km.h(-1) (D>14.4 km·h(-1)) and >80% of vYo-YoIR1 (D>80%vYo-YoIR1) were examined. Upon arrival at altitude, there was a greater decrement in vYo-YoIR1 (Cohen's d +1.0, 90%CL ± 0.8) and D>14.4 km·h(-1) (+0.5 ± 0.8) in AUS. D>14.4 km.h(-1) was similarly reduced relative to vYo-YoIR1 in both groups, so that D>80%vYo-YoIR1 remained similarly unchanged (-0.1 ± 0.8). Throughout the altitude sojourn, vYo-YoIR1 and D>14.4 km·h(-1) increased in parallel in AUS, so that D>80%vYo-YoIR1 remained stable in AUS (+6.0%/match, 90%CL ± 6.7); conversely D>80%vYo-YoIR1 decreased largely in BOL (-12.2%/match ± 6.2). In sea-level natives competing at high-altitude, changes in match running performance likely follow those in high-intensity running performance. Bolivian data confirm that increases in 'fitness' do not necessarily translate into greater match running performance, but rather in reduced relative exercise intensity. Key pointsWhen playing at high-altitude, players may alter their activities during matches in relation to their transient maximal physical capacities, possibly to maintain a 'tolerable' relative exercise intensity.While there is no doubt that running performance per se in not the main determinant of match outcomes (Carling, 2013), fitness levels influence relative match intensity (Buchheit et al., 2012, Mendez-Villanueva et al., 2013), which in-turn may impact on decision making and skill performance (Rampinini et al., 2008).In the context of

  7. Effects of light intensity and quality on phycobiliprotein accumulation in the cyanobacterium Nostoc sphaeroides Kützing.

    PubMed

    Ma, Rui; Lu, Fan; Bi, Yonghong; Hu, Zhengyu

    2015-08-01

    To assess the effects of light intensity and quality on the growth and phycobiliproteins (PBP) accumulation in Nostoc sphaeroides Kützing (N. sphaeroides). Dry weights, dry matter, protein, chlorophyll and PBP contents were higher under 90 μmol m(-2) s(-1) than under other intensities (both higher and lower). Phycocyanin and allophycocyanin increased with light intensity while phycoerythrin decreased. Fresh weights, protein and PBP contents increased at the highest rates under blue light. Red light resulted in higher values of dry matter, phycocyanin and chlorophyll a. White light at 90 μmol m(-2) s(-1) or blue light 30 μmol m(-2) s(-1) were optimal for the growth and phycobiliprotein accumulation in N. sphaeroides.

  8. Drift tube suspension for high intensity linear accelerators

    DOEpatents

    Liska, D.J.; Schamaun, R.G.; Clark, D.C.; Potter, R.C.; Frank, J.A.

    1980-03-11

    The disclosure relates to a drift tube suspension for high intensity linear accelerators. The system comprises a series of box-sections girders independently adjustably mounted on a linear accelerator. A plurality of drift tube holding stems are individually adjustably mounted on each girder.

  9. Rapid response of soil fungal communities to low and high intensity fire

    NASA Astrophysics Data System (ADS)

    Smith, Jane E.; Cowan, Ariel D.; Reazin, Chris; Jumpponen, Ari

    2016-04-01

    Contemporary fires have created high-severity burn areas exceeding historical distributions in forests in the western United States. Until recently, the response of soil ecosystems to high intensity burns has been largely unknown. In complementary studies, we investigated the environmental effect of extreme soil heating, such that occurs with the complete combustion of large down wood during wildfires, on soil fungi and nutrients. We used TRFLP and next generation sequencing (Illumina MiSeq) to investigate the fungal communities. During the burning of large down wood, temperatures lethal to fungi were detected at 0-cm, 5-cm, and 10-cm depths in soils compared to 0-cm depth in soils receiving low intensity broadcast burns. We compared the soil fungal diversity in ten high intensity burned plots paired with adjacent low intensity burned plots before and one week after at 0-10 cm soil depth. Nonmetric Multidimensional Scaling (NMS) ordinations and analyses of taxon frequencies reveal a substantial community turnover and corresponding near complete replacement of the dominant basidiomycetes by ascomycetes in high intensity burns. These coarse-level taxonomic responses were primarily attributable to a few fire-responsive (phoenicoid) fungi, particularly Pyronema sp. and Morchella sp., whose frequencies increased more than 100-fold following high intensity burns. Pinus ponderosa seedlings planted one week post-burn were harvested after four months for EMF root tip analysis. We found: a) greater differences in soil properties and nutrients in high intensity burned soils compared to low intensity burned and unburned soils; b) no differences in EMF richness and diversity; and c) weak differences in community composition based on relative abundance between unburned and either burn treatments. These results confirm the combustion of large downed wood can alter the soil environment directly beneath it. However, an EMF community similar to low burned soils recolonized high

  10. High-Quality Carbohydrates and Physical Performance

    PubMed Central

    Kanter, Mitch

    2018-01-01

    While all experts agreed that protein needs for performance are likely greater than believed in past generations, particularly for strength training athletes, and that dietary fat could sustain an active person through lower-intensity training bouts, current research still points to carbohydrate as an indispensable energy source for high-intensity performance. PMID:29449746

  11. Effects of intensive silvicultural treatments on kraft pulp quality of loblolly and slash pine

    Treesearch

    Charles E. Courchene; Alexander Clark; Monique L. Belli; William Jason Cooper; Barry D. Shiver

    2000-01-01

    Intensive forest-management practices have been shown to greatly increase the growth rates of southern pines. A joint study was undertaken to evaluate the wood and pulp quality from fast-grown 14-year-old loblolly pine from the Piedmont and 17-year-old slash pine from the Coastal Plain. The properties were compared to 24-year-old plantation-grown controls. three sets...

  12. High-Intensity Training Improves Global and Segmental Strains in Severe Congestive Heart Failure.

    PubMed

    Blumberg, Yair; Ertracht, Offir; Gershon, Itai; Bachner-Hinenzon, Noa; Reuveni, Tali; Atar, Shaul

    2017-05-01

    High-intensity training (HIT) is superior to moderate aerobic training (MAT) for improving quality of life in congestive heart failure (CHF) patients. Speckle-tracking echocardiography (STE) has recently been suggested for estimation of left ventricle global and regional function. We evaluated the utility of STE for characterizing differences in cardiac function following MAT or HIT in a CHF rat model. After baseline physiologic assessment, CHF was induced by means of coronary artery ligation in Sprague-Dawley rats. Repeated measurements confirmed the presence of CHF (ejection fraction 52 ± 10%, global circumferential strain (GCS) 10.5 ± 4, and maximal oxygen uptake (V˙O 2 max ) 71 ± 11 mL⋅min -1 ⋅kg -1 ; P < .001 vs baseline for all). Subsequently, rats were divided into training protocols: sedentary (SED), MAT, or HIT. After the training period, rats underwent the same measurements and were killed. Training intensity improved V˙O 2 max (73 ± 13 mL⋅min -1 ⋅kg -1 in MAT [P < .01 vs baseline] and 82 ± 6 mL⋅min -1 ⋅kg -1 in HIT [P < .05 vs baseline or SED] and ejection fraction (50 ± 21% in MAT [P < .001 vs baseline] and 66 ± 7% in HIT [P > .05 vs baseline]). In addition, strains of specific segments adjacent to the infarct zone regained basal values (P > .05 vs baseline), whereas global cardiac functional parameters as assessed with the use of 2-dimensional echocardiography did not improve. High-intensity exercise training improved function in myocardial segments remote from the scar, which resulted in compensatory cardiac remodeling. This effect is prominent, yet it could be detected only with the use of STE. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Fractal water quality fluctuations spanning the periodic table in an intensively farmed watershed.

    PubMed

    Aubert, Alice H; Kirchner, James W; Gascuel-Odoux, Chantal; Faucheux, Mikael; Gruau, Gérard; Mérot, Philippe

    2014-01-21

    Recently developed measurement technologies can monitor surface water quality almost continuously, creating high-frequency multiparameter time series and raising the question of how best to extract insights from such rich data sets. Here we use spectral analysis to characterize the variability of water quality at the AgrHys observatory (Western France) over time scales ranging from 20 min to 12 years. Three years of daily sampling at the intensively farmed Kervidy-Naizin watershed reveal universal 1/f scaling for all 36 solutes, yielding spectral slopes of 1.05 ± 0.11 (mean ± standard deviation). These 36 solute concentrations show varying degrees of annual cycling, suggesting different controls on watershed export processes. Twelve years of daily samples of SO4, NO3, and dissolved organic carbon (DOC) show that 1/f scaling does not continue at frequencies below 1/year in those constituents, whereas a 12-year daily record of Cl shows a general 1/f trend down to the lowest measurable frequencies. Conversely, approximately 12 months of 20 min NO3 and DOC measurements show that at frequencies higher than 1/day, the spectra of these solutes steepen to slopes of roughly 3, and at time scales shorter than 2-3 h, the spectra flatten to slopes near zero, reflecting analytical noise. These results confirm and extend the recent discovery of universal fractal 1/f scaling in water quality at the relatively pristine Plynlimon watershed in Wales, further demonstrating the importance of advective-dispersive transport mixing in catchments. However, the steeper scaling at subdaily time scales suggests additional short-term damping of solute concentrations, potentially due to in-stream or riparian processes.

  14. Improving the Context Supporting Quality Improvement in a Neonatal Intensive Care Unit Quality Collaborative: An Exploratory Field Study.

    PubMed

    Grooms, Heather R; Froehle, Craig M; Provost, Lloyd P; Handyside, James; Kaplan, Heather C

    Successful quality improvement (QI) requires a supportive context. The goal was to determine whether a structured curriculum could help QI teams improve the context supporting their QI work. An exploratory field study was conducted of 43 teams participating in a neonatal intensive care unit QI collaborative. Using a curriculum based on the Model for Understanding Success in Quality, teams identified gaps in their context and tested interventions to modify context. Surveys and self-reflective journals were analyzed to understand how teams developed changes to modify context. More than half (55%) targeted contextual improvements within the microsystem, focusing on motivation and culture. "Information sharing" interventions to communicate information about the project as a strategy to engage more staff were the most common interventions tested. Further study is needed to determine if efforts to modify context consistently lead to greater outcome improvements.

  15. The high intensity solar cell - Key to low cost photovoltaic power

    NASA Technical Reports Server (NTRS)

    Sater, B. L.; Goradia, C.

    1975-01-01

    This paper discusses the problems associated with conventional solar cells at high intensities and presents the design considerations and performance characteristics of the 'high intensity' (HI) solar cell which appears to eliminate the major problems. Test data obtained at greater than 250 AM1 suns gave a peak output power density of 2 W per sq cm at an efficiency exceeding 6% with an unoptimized cell operating at over 100 C. It appears that operation at 1000 AM1 suns at efficiencies greater than 10% is possible. At 1000 AM1 suns and 10% efficiency, the HI cell manufacturing cost is estimated to be $0.25/watt, with multi-megawatt annual production capability already existing within the industrial sector. A high intensity solar system was also analyzed to determine its cost effectiveness and to assess the benefits of further improving HI cell efficiency.

  16. Nonlinear absorption in biological tissue for high intensity focused ultrasound.

    PubMed

    Liu, Xiaozhou; Li, Junlun; Gong, Xiufen; Zhang, Dong

    2006-12-22

    In recent years the propagation of the high intensity focused ultrasound (HIFU) in biological tissue is an interesting area due to its potential applications in non-invasive treatment of disease. The base principle of these applications is the heat effect generated by ultrasound absorption. In order to control therapeutic efficiency, it is important to evaluate the heat generation in biological tissue irradiated by ultrasound. In his paper, based on the Khokhlov-Zabolotkaya-Kuznetsov (KZK) equation in frequency-domain, the numerical simulations of nonlinear absorption in biological tissues for high intensity focused ultrasound are performed. We find that ultrasound thermal transfer effect will be enhanced with the increasing of initial acoustic intensity due to the high harmonic generation. The concept of extra absorption factor is introduced to describe nonlinear absorption in biological tissue for HIFU. The theoretical results show that the heat deposition induced by the nonlinear theory can be nearly two times as large as that predicated by linear theory. Then, the influence of the diffraction effect on the position of the focus in HIFU is investigated. It is shown that the sound focus moves toward the transducer compared with the geometry focus because of the diffraction of the sound wave. The position of the maximum heat deposition is shifted to the geometry focus with the increase of initial acoustic intensity because the high harmonics are less diffraction. Finally, the temperature in the porcine fat tissue changing with the time is predicated by Pennes' equation and the experimental results verify the nonlinear theoretical prediction.

  17. Obstetric patients' health-related quality of life before and after intensive care.

    PubMed

    Pia, Seppänen; Reijo, Sund; Tero, Ala-Kokko; Mervi, Roos; Jukka, Uotila; Mika, Helminen; Tarja, Suominen

    2018-03-23

    Intensive care admissions during pregnancy, childbirth, and postpartum period are relatively well investigated. However, very little is known about these obstetric patients' health-related quality of life (HRQoL) before and after critical care. The objective of this study was to assess obstetric patients' HRQoL before intensive care admission (baseline) and at 6 months after discharge (follow-up) DESIGN: This was a retrospective database study. In a 5-year period, the data of all women admitted to the intensive care unit (ICU) during pregnancy, delivery, or up to 42 days postpartum were analysed. Four multidisciplinary ICUs of Finnish University hospitals participated. The HRQoL was assessed using the EuroQol-5D (EQ-5D) instrument with utility score (EQsum) and visual analogue scale (EQ-VAS). A total of 283 obstetric patients were identified from the clinical information system. Of these, 99 (35%) completed the EQ-5D questionnaires both at baseline and follow-up, and 65 of them (23%) completed EQ-VAS. The comparison of patients' EQsum scores before intensive care admission and after discharge showed that patients' HRQoL remained good (0.970 vs 0.972) (max 1.0) or increased (0.788 vs 0.982) in 80.8% of the patients. Patients reported improved overall health on the EQ-VAS at 6 months follow-up (EQ-VAS mean, 71.86 vs 88.20; p ≤ 0.001) (max 100). However, 19.2% of the patients had lower HRQoL (EQsum mean 0.987 vs 0.798) at follow-up. Following intensive care, 15% of the patients had more pain/discomfort, and 11% expressed more depression/anxiety. Multiparous patients were more likely to suffer from worsened depression/anxiety (p = 0.024). In the majority of the obstetric patients, HRQoL at 6 months follow-up remained good or had increased from baseline. However, nearly one-fifth of the patients had impaired HRQoL after discharge. Thus, intensive care management should take in to consideration follow-up program after intensive care of ICU-admitted obstetric

  18. High intensity, pulsed thermal neutron source

    DOEpatents

    Carpenter, J.M.

    1973-12-11

    This invention relates to a high intensity, pulsed thermal neutron source comprising a neutron-producing source which emits pulses of fast neutrons, a moderator block adjacent to the last neutron source, a reflector block which encases the fast neutron source and the moderator block and has a thermal neutron exit port extending therethrough from the moderator block, and a neutron energy- dependent decoupling reflector liner covering the interior surfaces of the thermal neutron exit port and surrounding all surfaces of the moderator block except the surface viewed by the thermal neutron exit port. (Official Gazette)

  19. Negative beliefs about low back pain are associated with persistent high intensity low back pain.

    PubMed

    Ng, Sin Ki; Cicuttini, Flavia M; Wang, Yuanyuan; Wluka, Anita E; Fitzgibbon, Bernadette; Urquhart, Donna M

    2017-08-01

    While previous cross-sectional studies have found that negative beliefs about low back pain are associated with pain intensity, the relationship between back beliefs and persistent low back pain is not well understood. This cohort study aimed to examine the role of back beliefs in persistent low back pain in community-based individuals. A hundred and ninety-two participants from a previous musculoskeletal health study were invited to take part in a two-year follow-up study. Beliefs about back pain were assessed by the Back Beliefs Questionnaire (BBQ) at baseline and low back pain intensity was measured by the Chronic Pain Grade Questionnaire at baseline and follow-up. Of the 150 respondents (78.1%), 16 (10.7%) reported persistent high intensity low back pain, 12 (8.0%) developed high intensity low back pain, in 16 (10.7%) their high intensity low back pain resolved and 106 (70.7%) experienced no high intensity low back pain. While participants were generally positive about low back pain (BBQ mean (SD) = 30.2 (6.4)), those with persistent high intensity pain reported greater negativity (BBQ mean (SD) = 22.6 (4.9)). Negative beliefs about back pain were associated with persistent high intensity low back pain after adjusting for confounders (M (SE) = 23.5 (1.6) vs. >30.1 (1.7), p < .001). This study found negative back beliefs were associated with persistent high intensity low back pain over 2 years in community-based individuals. While further longitudinal studies are required, these findings suggest that targeting beliefs in programs designed to treat and prevent persistent high intensity low back pain may be important.

  20. Probing the positron moderation process using high-intensity, highly polarized slow-positron beams

    NASA Technical Reports Server (NTRS)

    Van House, J.; Zitzewitz, P. W.

    1984-01-01

    A highly polarized (P = 0.48 + or - 0.02) intense (500,000/sec) beam of 'slow' (Delta E = about 2 eV) positrons (e+) is generated, and it is shown that it is possible to achieve polarization as high as P = 0.69 + or - 0.04 with reduced intensity. The measured polarization of the slow e+ emitted by five different positron moderators showed no dependence on the moderator atomic number (Z). It is concluded that only source positrons with final kinetic energy below 17 keV contribute to the slow-e+ beam, in disagreement with recent yield functions derived from low-energy measurements. Measurements of polarization and yield with absorbers of different Z between the source and moderator show the effects of the energy and angular distributions of the source positrons on P. The depolarization of fast e+ transmitted through high-Z absorbers has been measured. Applications of polarized slow-e+ beams are discussed.

  1. Effect of Short-Term, High-Intensity Exercise on Anaerobic Threshold in Women.

    ERIC Educational Resources Information Center

    Evans, Blanche W.

    This study investigated the effects of a six-week, high-intensity cycling program on anaerobic threshold (AT) in ten women. Subjects trained four days a week using high-intensity interval-type cycle exercises. Workouts included six 4-minute intervals cycling at 85 percent maximal oxygen uptake (VO sub 2 max), separated by 3-minute intervals of…

  2. High-intensity intermittent swimming improves cardiovascular health status for women with mild hypertension.

    PubMed

    Mohr, Magni; Nordsborg, Nikolai Baastrup; Lindenskov, Annika; Steinholm, Hildigunn; Nielsen, Hans Petur; Mortensen, Jann; Weihe, Pal; Krustrup, Peter

    2014-01-01

    To test the hypothesis that high-intensity swim training improves cardiovascular health status in sedentary premenopausal women with mild hypertension, sixty-two women were randomized into high-intensity (n = 21; HIT), moderate-intensity (n = 21; MOD), and control groups (n = 20; CON). HIT performed 6-10 × 30 s all-out swimming interspersed by 2 min recovery and MOD swam continuously for 1 h at moderate intensity for a 15-week period completing in total 44 ± 1 and 43 ± 1 sessions, respectively. In CON, all measured variables were similar before and after the intervention period. Systolic BP decreased (P < 0.05) by 6 ± 1 and 4 ± 1 mmHg in HIT and MOD; respectively. Resting heart rate declined (P < 0.05) by 5 ± 1 bpm both in HIT and MOD, fat mass decreased (P < 0.05) by 1.1 ± 0.2 and 2.2 ± 0.3 kg, respectively, while the blood lipid profile was unaltered. In HIT and MOD, performance improved (P < 0.05) for a maximal 10 min swim (13 ± 3% and 22 ± 3%), interval swimming (23 ± 3% and 8 ± 3%), and Yo-Yo IE1 running performance (58 ± 5% and 45 ± 4%). In conclusion, high-intensity intermittent swimming is an effective training strategy to improve cardiovascular health and physical performance in sedentary women with mild hypertension. Adaptations are similar with high- and moderate-intensity training, despite markedly less total time spent and distance covered in the high-intensity group.

  3. High-Intensity Intermittent Swimming Improves Cardiovascular Health Status for Women with Mild Hypertension

    PubMed Central

    Mohr, Magni; Nordsborg, Nikolai Baastrup; Lindenskov, Annika; Steinholm, Hildigunn; Nielsen, Hans Petur; Mortensen, Jann; Weihe, Pal; Krustrup, Peter

    2014-01-01

    To test the hypothesis that high-intensity swim training improves cardiovascular health status in sedentary premenopausal women with mild hypertension, sixty-two women were randomized into high-intensity (n = 21; HIT), moderate-intensity (n = 21; MOD), and control groups (n = 20; CON). HIT performed 6–10 × 30 s all-out swimming interspersed by 2 min recovery and MOD swam continuously for 1 h at moderate intensity for a 15-week period completing in total 44 ± 1 and 43 ± 1 sessions, respectively. In CON, all measured variables were similar before and after the intervention period. Systolic BP decreased (P < 0.05) by 6 ± 1 and 4 ± 1 mmHg in HIT and MOD; respectively. Resting heart rate declined (P < 0.05) by 5 ± 1 bpm both in HIT and MOD, fat mass decreased (P < 0.05) by 1.1 ± 0.2 and 2.2 ± 0.3 kg, respectively, while the blood lipid profile was unaltered. In HIT and MOD, performance improved (P < 0.05) for a maximal 10 min swim (13 ± 3% and 22 ± 3%), interval swimming (23 ± 3% and 8 ± 3%), and Yo-Yo IE1 running performance (58 ± 5% and 45 ± 4%). In conclusion, high-intensity intermittent swimming is an effective training strategy to improve cardiovascular health and physical performance in sedentary women with mild hypertension. Adaptations are similar with high- and moderate-intensity training, despite markedly less total time spent and distance covered in the high-intensity group. PMID:24812628

  4. Nanoplasma Formation by High Intensity Hard X-rays

    PubMed Central

    Tachibana, T.; Jurek, Z.; Fukuzawa, H.; Motomura, K.; Nagaya, K.; Wada, S.; Johnsson, P.; Siano, M.; Mondal, S.; Ito, Y.; Kimura, M.; Sakai, T.; Matsunami, K.; Hayashita, H.; Kajikawa, J.; Liu, X.-J.; Robert, E.; Miron, C.; Feifel, R.; Marangos, J. P.; Tono, K.; Inubushi, Y.; Yabashi, M.; Son, S.-K.; Ziaja, B.; Yao, M.; Santra, R.; Ueda, K.

    2015-01-01

    Using electron spectroscopy, we have investigated nanoplasma formation from noble gas clusters exposed to high-intensity hard-x-ray pulses at ~5 keV. Our experiment was carried out at the SPring-8 Angstrom Compact free electron LAser (SACLA) facility in Japan. Dedicated theoretical simulations were performed with the molecular dynamics tool XMDYN. We found that in this unprecedented wavelength regime nanoplasma formation is a highly indirect process. In the argon clusters investigated, nanoplasma is mainly formed through secondary electron cascading initiated by slow Auger electrons. Energy is distributed within the sample entirely through Auger processes and secondary electron cascading following photoabsorption, as in the hard x-ray regime there is no direct energy transfer from the field to the plasma. This plasma formation mechanism is specific to the hard-x-ray regime and may, thus, also be important for XFEL-based molecular imaging studies. In xenon clusters, photo- and Auger electrons contribute more significantly to the nanoplasma formation. Good agreement between experiment and simulations validates our modelling approach. This has wide-ranging implications for our ability to quantitatively predict the behavior of complex molecular systems irradiated by high-intensity hard x-rays. PMID:26077863

  5. Dynamics of Cavitation Clouds within a High-Intensity Focused Ultrasonic Beam

    DTIC Science & Technology

    2012-03-01

    the cloud size. I. INTRODUCTION High-intensity focused ultrasound ( HIFU ), along with the associated cavitation, is used in a variety of fields. The...this experimental study, we generate a 500 kHz high-intensity focused ultrasonic ( HIFU ) beam, with pressure amplitude in the focal zone of up to 1.9 MPa... focused ultrasonic ( HIFU ) beam, with pressure amplitude in the focal zone of up to 1.9 MPa, in initially quiescent water. The resulting pressure field

  6. Sustainability of High Intensity Forest Management with Respect to Water QuaIity and Site Nutrient Reserves

    Treesearch

    Virginia R. Tolbert; Carl C. Trettin; Dale W. Johnson; John W. Parsons; Allan E. Houston; David A. Mays

    2001-01-01

    Ensuring sustainability of intensively managed woody crops requires determining soil and water quality effects using a combination of field data and modeling projections. Plot- and catchrnent-scale research, models, and meta-analyses are addressing nutrient availability, site quality, and measures to increase short-rotation woody crop (SRWC) productivity and site...

  7. High Intensity Interval Training Leads to Greater Improvements in Acute Heart Rate Recovery and Anaerobic Power as High Volume Low Intensity Training.

    PubMed

    Stöggl, Thomas L; Björklund, Glenn

    2017-01-01

    The purpose of the current study was to explore if training regimes utilizing diverse training intensity distributions result in different responses on neuromuscular status, anaerobic capacity/power and acute heart rate recovery (HRR) in well-trained endurance athletes. Methods: Thirty-six male ( n = 33) and female ( n = 3) runners, cyclists, triathletes and cross-country skiers [peak oxygen uptake: (VO 2peak ): 61.9 ± 8.0 mL·kg -1 ·min -1 ] were randomly assigned to one of three groups (blocked high intensity interval training HIIT; polarized training POL; high volume low intensity oriented control group CG/HVLIT applying no HIIT). A maximal anaerobic running/cycling test (MART/MACT) was performed prior to and following a 9-week training period. Results: Only the HIIT group achieved improvements in peak power/velocity (+6.4%, P < 0.001) and peak lactate ( P = 0.001) during the MART/MACT, while, unexpectedly, in none of the groups the performance at the established lactate concentrations (4, 6, 10 mmol·L -1 ) was changed ( P > 0.05). Acute HRR was improved in HIIT (11.2%, P = 0.002) and POL (7.9%, P = 0.023) with no change in the HVLIT oriented control group. Conclusion: Only a training regime that includes a significant amount of HIIT improves the neuromuscular status, anaerobic power and the acute HRR in well-trained endurance athletes. A training regime that followed more a low and moderate intensity oriented model (CG/HVLIT) had no effect on any performance or HRR outcomes.

  8. High Intensity Interval Training Leads to Greater Improvements in Acute Heart Rate Recovery and Anaerobic Power as High Volume Low Intensity Training

    PubMed Central

    Stöggl, Thomas L.; Björklund, Glenn

    2017-01-01

    The purpose of the current study was to explore if training regimes utilizing diverse training intensity distributions result in different responses on neuromuscular status, anaerobic capacity/power and acute heart rate recovery (HRR) in well-trained endurance athletes. Methods: Thirty-six male (n = 33) and female (n = 3) runners, cyclists, triathletes and cross-country skiers [peak oxygen uptake: (VO2peak): 61.9 ± 8.0 mL·kg−1·min−1] were randomly assigned to one of three groups (blocked high intensity interval training HIIT; polarized training POL; high volume low intensity oriented control group CG/HVLIT applying no HIIT). A maximal anaerobic running/cycling test (MART/MACT) was performed prior to and following a 9-week training period. Results: Only the HIIT group achieved improvements in peak power/velocity (+6.4%, P < 0.001) and peak lactate (P = 0.001) during the MART/MACT, while, unexpectedly, in none of the groups the performance at the established lactate concentrations (4, 6, 10 mmol·L−1) was changed (P > 0.05). Acute HRR was improved in HIIT (11.2%, P = 0.002) and POL (7.9%, P = 0.023) with no change in the HVLIT oriented control group. Conclusion: Only a training regime that includes a significant amount of HIIT improves the neuromuscular status, anaerobic power and the acute HRR in well-trained endurance athletes. A training regime that followed more a low and moderate intensity oriented model (CG/HVLIT) had no effect on any performance or HRR outcomes. PMID:28824457

  9. Effects of High Intensity Interval Training on Increasing Explosive Power, Speed, and Agility

    NASA Astrophysics Data System (ADS)

    Fajrin, F.; Kusnanik, N. W.; Wijono

    2018-01-01

    High Intensity Interval Training (HIIT) is a type of exercise that combines high-intensity exercise and low intensity exercise in a certain time interval. This type of training is very effective and efficient to improve the physical components. The process of improving athletes achievement related to how the process of improving the physical components, so the selection of a good practice method will be very helpful. This study aims to analyze how is the effects of HIIT on increasing explosive power, speed, and agility. This type of research is quantitative with quasi-experimental methods. The design of this study used the Matching-Only Design, with data analysis using the t-test (paired sample t-test). After being given the treatment for six weeks, the results showed there are significant increasing in explosive power, speed, and agility. HIIT in this study used a form of exercise plyometric as high-intensity exercise and jogging as mild or moderate intensity exercise. Increase was due to the improvement of neuromuscular characteristics that affect the increase in muscle strength and performance. From the data analysis, researchers concluded that, Exercises of High Intensity Interval Training significantly effect on the increase in Power Limbs, speed, and agility.

  10. High-intensity interval training in patients with coronary heart disease: Prescription models and perspectives.

    PubMed

    Ribeiro, Paula A B; Boidin, Maxime; Juneau, Martin; Nigam, Anil; Gayda, Mathieu

    2017-01-01

    Recently, high-intensity interval training (HIIT) has emerged as an alternative and/or complementary exercise modality to continuous aerobic exercise training (CAET) in CHD patients. However, the literature contains descriptions of many HIIT protocols with different stage durations, nature of recovery and intensities. In this review, we discuss the most recent forms of validated HIIT protocols in patients with coronary heart disease (CHD) and how to prescribe and use them during short- and long-term (phase II and III) cardiac rehabilitation programs. We also compare the superior and/or equivalent short- and long-term effects of HIIT versus CAET on aerobic fitness, cardiovascular function, and quality of life; their efficiency, safety, and tolerance; and exercise adherence. Short interval HIIT was found beneficial for CHD patients with lower aerobic fitness and would ideally be used in initiation and improvement stages. Medium and/or long interval HIIT protocols may be beneficial for CHD patients with higher aerobic fitness, and would be ideally used in the improvement and maintenance stages because of their high physiological stimulus. Finally, we propose progressive individualized models of HIIT programs (phase II to III) for patients with CHD and how to ideally use them according to the clinical status of patients and phase of the cardiac rehabilitation program. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  11. High-Intensity Interval Training for Improving Postprandial Hyperglycemia

    ERIC Educational Resources Information Center

    Little, Jonathan P.; Francois, Monique E.

    2014-01-01

    High-intensity interval training (HIIT) has garnered attention in recent years as a time-efficient exercise option for improving cardiovascular and metabolic health. New research demonstrates that HIIT may be particularly effective for improving postprandial hyperglycemia in individuals with, or at risk for, type 2 diabetes (T2D). These findings…

  12. High pressure versus high intensity noninvasive ventilation in stable hypercapnic chronic obstructive pulmonary disease: a randomized crossover trial.

    PubMed

    Murphy, Patrick B; Brignall, Kate; Moxham, John; Polkey, Michael I; Davidson, A Craig; Hart, Nicholas

    2012-01-01

    High-intensity (high-pressure and high backup rate) noninvasive ventilation has recently been advocated for the management of stable hypercapnic chronic obstructive pulmonary disease (COPD). However, the relative contributions of high inspiratory pressure and high backup rate to ventilator adherence and physiological outcome have not been investigated. Patients with stable hypercapnic COPD (daytime PaCO(2) > 6 kPa) and nocturnal hypoventilation were enrolled. Patients were randomly allocated to high-pressure and high backup rate (high-intensity) and high-pressure and low backup rate (high-pressure) for a 6-week period. At the end of the first treatment period, patients were switched to the alternative treatment. The primary outcome measure was mean nightly ventilator usage. Twelve patients were recruited, with seven completing the 12-week trial protocol. The mean patient age was 71 ± 8 years, with a forced expiratory volume in one second (FEV(1))/forced vital capacity (FVC) of 50% ± 13% and FEV(1) of 32% ± 12%. The baseline PaCO(2) and PaO(2) were 8.6 ± 1.7 kPa and 7.3 ± 1.4 kPa, respectively. There was no significant difference demonstrated in mean nightly ventilator usage between the high-intensity and high-pressure groups (difference of 4 minutes; 95% confidence interval -45 to 53; P = 0.9). Furthermore, there were no differences in any of the secondary endpoints, with the exception of the respiratory domain of the Severe Respiratory Insufficiency questionnaire, which was lower in the high-intensity arm than in the high-pressure arm (57 ± 11 versus 69 ± 16; P < 0.05). There was no additional benefit, in terms of night-time ventilator adherence or any of the other measured parameters, demonstrated by addition of a high backup rate to high-pressure noninvasive ventilation. These data suggest that it is the high-pressure component of the high-intensity noninvasive ventilation approach that plays the important therapeutic role in the management of hypercapnic

  13. The Effects of Aromatherapy on Intensive Care Unit Patients' Stress and Sleep Quality: A Nonrandomised Controlled Trial

    PubMed Central

    Cho, Eun Hee; Lee, Mi-Young

    2017-01-01

    Background Stress has both physiological and psychological effects and can negatively impact patients' treatment and recovery. We examined whether the aromatherapy alleviated patients' stress and improved their sleep quality and provided data that can be utilized in clinical settings. Methods This was a nonrandomised controlled experimental study. Participants included lucid adult patients who were admitted to the intensive care unit and had spent more than two nights there. The experimental treatment required participants to engage in deep breathing with essential oils as part of the aromatherapy. The control group was instructed to go to sleep without receiving the lavender aroma oil. Results The experimental group and control group showed a significant difference in perceived stress (F = 60.11, p < .001), objective stress index (F = 25.65, p < .001), systolic blood pressure (F = 9.09, p < .001), diastolic blood pressure (F = 2.47, p = .046), heart rate (F = 5.71, p < .001), and sleep quality (F = 109.46, p < .001). Conclusions The results revealed that aromatherapy alleviated stress and improved sleep quality in intensive care unit patients after 2 days of the experimental treatment. These results demonstrate that aromatherapy affects stress and sleep quality, thus indicating its value in nursing interventions. This trial is registered with KCT0002344. PMID:29375641

  14. Understanding space charge and controlling beam loss in high intensity synchrotrons

    NASA Astrophysics Data System (ADS)

    Cousineau, Sarah M.

    Future high intensity synchrotrons will require unprecedented control of beam loss in order to comply with radiation safety regulations and to allow for safe, hands-on maintenance of machine hardware. A major cause of beam loss in high intensity synchrotrons is the space charge force of the beam, which can lead to beam halo and emittance dilution. This dissertation presents a comprehensive study of space charge effects in high intensity synchrotron beams. Experimental measurements taken at the Proton Storage Ring (PSR) in Los Alamos National Laboratory and detailed simulations of the experiments are used to identify and characterize resonances that affect these beams. The collective motion of the beam is extensively studied and is shown to be more relevant than the single particle dynamics in describing the resonance response. The emittance evolution of the PSR beam and methods for reducing the space-charge-induced emittance growth are addressed. In a separate study, the emittance evolution of an intense space charge beam is experimentally measured at the Cooler Injector Synchrotron (CIS) at Indiana University. This dissertation also investigates the sophisticated two-stage collimation system of the future Spallation Neutron Source (SNS) high intensity accumulator ring. A realistic Monte-Carlo collimation simulation is developed and used to optimize the SNS ring collimation system parameters. The finalized parameters and predicted beam loss distribution around the ring are presented. The collimators will additionally be used in conjunction with a set of fast kickers to remove the beam from the gap region before the rise of the extraction magnets. The gap cleaning process is optimized and the cleaning efficiency versus momentum spread of the beam is examined.

  15. Carcass and meat quality of Gokceada Goat kids reared under extensive and semi-intensive production systems.

    PubMed

    Ozcan, Mustafa; Yalcintan, Hulya; Tölü, Cemil; Ekiz, Bulent; Yilmaz, Alper; Savaş, Türker

    2014-01-01

    The aim was to compare the carcass and meat quality characteristics of male and female Gokceada Goat kids produced in extensive (n=20) and semi-intensive (n=20) systems. In extensive and semi-intensive produced kids pre-slaughter weights were 17.44 and 12.51 kg; cold carcass weights were 8.66 and 5.35 kg and cold dressing percentages were 54.9 and 49.28%, respectively. The effect of kid sex was not significant on hot and cold dressing percentages, back fat thickness, M. longissimus dorsi section area, carcass fatness and conformation scores, and carcass measurements, while female kids had higher omental and mesenteric fat and kidney knob and channel fat percentages than male kids. Extensive produced kids had lower meat lightness. Panellists evaluated extensive system kids with higher scores of kid odour intensity, flavour intensity and overall acceptability. It was concluded that it would be more appropriate to use an extensive system in Gokceada Goat breeding for kid meat production. © 2013.

  16. Preventing overtraining in athletes in high-intensity sports and stress/recovery monitoring.

    PubMed

    Kellmann, M

    2010-10-01

    In sports, the importance of optimizing the recovery-stress state is critical. Effective recovery from intense training loads often faced by elite athletes can often determine sporting success or failure. In recent decades, athletes, coaches, and sport scientists have been keen to find creative, new methods for improving the quality and quantity of training for athletes. These efforts have consistently faced barriers, including overtraining, fatigue, injury, illness, and burnout. Physiological and psychological limits dictate a need for research that addresses the avoidance of overtraining, maximizes recovery, and successfully negotiates the fine line between high and excessive training loads. Monitoring instruments like the Recovery-Stress Questionnaire for Athletes can assist with this research by providing a tool to assess their perceived state of recovery. This article will highlight the importance of recovery for elite athletes and provide an overview of monitoring instruments. © 2010 John Wiley & Sons A/S.

  17. 76 FR 44613 - Designation of Eight Counties as High Intensity Drug Trafficking Areas

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-26

    ... OFFICE OF NATIONAL DRUG CONTROL POLICY Designation of Eight Counties as High Intensity Drug Trafficking Areas AGENCY: Office of National Drug Control Policy. ACTION: Notice. SUMMARY: The Director of the Office of National Drug Control Policy has designated eight additional counties as High Intensity Drug...

  18. Warm-up strategy and high-intensity endurance performance in trained cyclists.

    PubMed

    Christensen, Peter M; Bangsbo, Jens

    2015-04-01

    To evaluate the influence of warm-up exercise intensity and subsequent recovery on intense endurance performance, selected blood variables, and the oxygen-uptake (VO2) response. Twelve highly trained male cyclists (VO2max 72.4 ± 8.0 mL · min-1 · kg-1, incremental-test peak power output (iPPO) 432 ± 31 W; mean ± SD) performed 3 warm-up strategies lasting 20 min before a 4-min maximal-performance test (PT). Strategies consisted of moderate-intensity exercise (50%iPPO) followed by 6 min of recovery (MOD6) or progressive high-intensity exercise (10-100%iPPO and 2 × 20-s sprints) followed by recovery for 6 min (HI6) or 20 min (HI20). Before PT venous pH was lower (P < .001) in HI6 (7.27 ± 0.05) than in HI20 (7.34 ± 0.04) and MOD6 (7.35 ± 0.03). At the same time, differences (P < .001) existed for venous lactate in HI6 (8.2 ± 2.0 mmol/L), HI20 (5.1 ± 1.7 mmol/L), and MOD6 (1.4 ± 0.4 mmol/L), as well as for venous bicarbonate in HI6 (19.3 ± 2.6 mmol/L), HI20 (22.6 ± 2.3 mmol/L), and MOD6 (26.0 ± 1.4 mmol/L). Mean power in PT in HI6 (402 ± 38 W) tended to be lower (P = .11) than in HI20 (409 ± 34 W) and was lower (P = .007) than in MOD6 (416 ± 32 W). Total VO2 (15-120 s in PT) was higher in HI6 (8.18 ± 0.86 L) than in HI20 (7.85 ± 0.82 L, P = .008) and MOD6 (7.90 ± 0.74 L, P = .012). Warm-up exercise including race-pace and sprint intervals combined with short recovery can reduce subsequent performance in a 4-min maximal test in highly trained cyclists. Thus, a reduced time at high exercise intensity, a reduced intensity in the warm-up, or an extension of the recovery period after an intense warm-up is advocated.

  19. High-Performance and Self-Powered Deep UV Photodetectors Based on High Quality 2D Boron Nitride Nanosheets

    PubMed Central

    Rivera, Manuel; Rahaman, Mostafizur; Zhou, Andrew F.; Mohammed Alzuraiqi, Waleed; Feng, Peter

    2017-01-01

    High-quality two-dimensional (2D) crystalline boron nitride nanosheets (BNNSs) were grown on silicon wafers by using pulsed plasma beam deposition techniques. Self-powered deep ultraviolet (DUV) photodetectors (PDs) based on BNNSs with Schottky contact structures are designed and fabricated. By connecting the fabricated DUV photodetector to an ammeter, the response strength, response time and recovery time to different DUV wavelengths at different intensities have been characterized using the output short circuit photocurrent without a power supply. Furthermore, effects of temperature and plasma treatment on the induced photocurrent response of detectors have also been investigated. The experimental data clearly indicate that plasma treatment would significantly improve both induced photocurrent and response time. The BNNS-based DUV photodetector is demonstrated to possess excellent performance at a temperature up to 400 °C, including high sensitivity, high signal-to-noise ratio, high spectral selectivity, high speed, and high stability, which is better than almost all reported semiconducting nanomaterial-based self-powered photodetectors. PMID:29257098

  20. A new method of creating high intensity neutron source

    NASA Astrophysics Data System (ADS)

    Masuda, T.; Yoshimi, A.; Yoshimura, M.

    We propose a new scheme of producing an intense neutron beam whose yields may exceed those of the existing facilities by a few to several orders of magnitude in the sub-eV region. This scheme employs a MeV gamma beam extracted from circulating quantum ions, which has been recently proposed. The gamma beam is directed to a deuteron target and the photo-disintegration process generates a neutron beam. The calculated neutron energy spectrum is nearly flat down to the neV range, and thus there exists a possibility to utilize a good quality of neutrons especially in sub-eV energy region without using a moderator.

  1. High intensity portable fluorescent light

    NASA Technical Reports Server (NTRS)

    Kendall, F. B.

    1972-01-01

    Eight high intensity portable fluorescent lights were produced. Three prototype lights were also produced, two of which were subsequently updated to the physical and operational configuration of the qualification and flight units. Positioning of lamp apertures and reflectors in these lights is such that the light is concentrated and intensified in a specific pattern rather than widely diffused. Indium amalgam control of mercury vapor pressure in the lamp gives high output at lamp ambient temperatures up to 105 C. A small amount of amalgam applied to each electrode stem helps to obtain fast warm-up. Shrinking a Teflon sleeve on the tube and potting metal caps on each end of the lamp minimizes dispersion of mercury vapor and glass particles in the event of accidental lamp breakage. Operation at 20 kHz allows the lamps to consume more power than at low frequency, thus increasing their light output and raising their efficiency. When used to expose color photographic film, light from the lamps produces results approximately equal to sunlight.

  2. Uterine fibroids: Influence of "T2-Rim sign" on immediate therapeutic responses to magnetic resonance imaging-guided high-intensity focused ultrasound ablation.

    PubMed

    Yeo, Sin Yuin; Kim, Young-Sun; Lim, Hyo Keun; Rhim, Hyunchul; Jung, Sin-Ho; Hwang, Na Young

    2017-12-01

    To investigate the influence of a high-signal-intensity peripheral rim on T2-weighted MR images (i.e., T2-rim sign) on the immediate therapeutic responses of MR-guided high intensity focused ultrasound (MR-HIFU) ablation of uterine fibroids. This retrospective study was approved by the institutional review board, and patient informed consent was obtained for MR-HIFU ablation. In total, 196 fibroids (diameter 6.2±2.6cm) in 123 women (age 43.4±5.0 years) who underwent MR-HIFU ablation from January 2013 to April 2016 were included. The effects of a T2-rim sign on the immediate therapeutic responses (non-perfused volume [NPV] ratio, ablation efficiency [NPV/treatment cell volume], ablation quality [grade 1-5, poor to excellent]) were investigated with univariable and multivariable analyses using generalized estimating equation (GEE) analysis. In multivariable analysis, T2 signal intensity ratio of fibroids-to-skeletal muscle, relative peak enhancement of fibroids, and subcutaneous fat thickness were also considered. The presence of a T2-rim sign significantly lowered the NPV ratio (54.0±28.0% vs. 83.7±17.7%), ablation efficiency (0.6±0.5 vs. 1.3±0.6), ablation quality (3.1±1.2 vs. 4.2±0.8), (P<0.0001). GEE analysis showed that the presence of a T2-rim sign was independently significant for ablation efficiency and ablation quality (P<0.05). Uterine fibroids with a T2-rim sign showed significantly poorer immediate therapeutic responses to MR-HIFU ablation. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Zerodur polishing process for high surface quality and high efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tesar, A.; Fuchs, B.

    1992-08-01

    Zerodur is a glass-ceramic composite importance in applications where temperature instabilities influence optical and mechanical performance, such as in earthbound and spaceborne telescope mirror substrates. Polished Zerodur surfaces of high quality have been required for laser gyro mirrors. Polished surface quality of substrates affects performance of high reflection coatings. Thus, the interest in improving Zerodur polished surface quality has become more general. Beyond eliminating subsurface damage, high quality surfaces are produced by reducing the amount of hydrated material redeposited on the surface during polishing. With the proper control of polishing parameters, such surfaces exhibit roughnesses of

  4. Grassland-Cropping Rotations: An Avenue for Agricultural Diversification to Reconcile High Production with Environmental Quality

    NASA Astrophysics Data System (ADS)

    Lemaire, Gilles; Gastal, François; Franzluebbers, Alan; Chabbi, Abad

    2015-11-01

    A need to increase agricultural production across the world to ensure continued food security appears to be at odds with the urgency to reduce the negative environmental impacts of intensive agriculture. Around the world, intensification has been associated with massive simplification and uniformity at all levels of organization, i.e., field, farm, landscape, and region. Therefore, we postulate that negative environmental impacts of modern agriculture are due more to production simplification than to inherent characteristics of agricultural productivity. Thus by enhancing diversity within agricultural systems, it should be possible to reconcile high quantity and quality of food production with environmental quality. Intensification of livestock and cropping systems separately within different specialized regions inevitably leads to unacceptable environmental impacts because of the overly uniform land use system in intensive cereal areas and excessive N-P loads in intensive animal areas. The capacity of grassland ecosystems to couple C and N cycles through microbial-soil-plant interactions as a way for mitigating the environmental impacts of intensive arable cropping system was analyzed in different management options: grazing, cutting, and ley duration, in order to minimize trade-offs between production and the environment. We suggest that integrated crop-livestock systems are an appropriate strategy to enhance diversity. Sod-based rotations can temporally and spatially capture the benefits of leys for minimizing environmental impacts, while still maintaining periods and areas of intensive cropping. Long-term experimental results illustrate the potential of such systems to sequester C in soil and to reduce and control N emissions to the atmosphere and hydrosphere.

  5. Grassland-Cropping Rotations: An Avenue for Agricultural Diversification to Reconcile High Production with Environmental Quality.

    PubMed

    Lemaire, Gilles; Gastal, François; Franzluebbers, Alan; Chabbi, Abad

    2015-11-01

    A need to increase agricultural production across the world to ensure continued food security appears to be at odds with the urgency to reduce the negative environmental impacts of intensive agriculture. Around the world, intensification has been associated with massive simplification and uniformity at all levels of organization, i.e., field, farm, landscape, and region. Therefore, we postulate that negative environmental impacts of modern agriculture are due more to production simplification than to inherent characteristics of agricultural productivity. Thus by enhancing diversity within agricultural systems, it should be possible to reconcile high quantity and quality of food production with environmental quality. Intensification of livestock and cropping systems separately within different specialized regions inevitably leads to unacceptable environmental impacts because of the overly uniform land use system in intensive cereal areas and excessive N-P loads in intensive animal areas. The capacity of grassland ecosystems to couple C and N cycles through microbial-soil-plant interactions as a way for mitigating the environmental impacts of intensive arable cropping system was analyzed in different management options: grazing, cutting, and ley duration, in order to minimize trade-offs between production and the environment. We suggest that integrated crop-livestock systems are an appropriate strategy to enhance diversity. Sod-based rotations can temporally and spatially capture the benefits of leys for minimizing environmental impacts, while still maintaining periods and areas of intensive cropping. Long-term experimental results illustrate the potential of such systems to sequester C in soil and to reduce and control N emissions to the atmosphere and hydrosphere.

  6. Quality of life of pulmonary TB patients after intensive phase treatmentin the health centers of Medan city, Indonesia

    NASA Astrophysics Data System (ADS)

    Wahyuni, A. S.; Soeroso, N.; Harahap, J.; Amelia, R.; Alona, I.

    2018-03-01

    Tuberculosis (TB) is one of the chronic diseases that has become a long major health problem in the world, as well as in Indonesia. TB treatment takes a long time (6-9 months) to cover both intensive and advanced phases. TB patients experience significant disruptions in their social life, exposed to stigma and discrimination. The purpose of this study was to determine the quality of life of TB patients after two months of TB intensive treatment phase. We conducted a quantitative study through cross-sectional design. This research recruited 100 TB patients aged > 18 years old and Category I with AFB(+) result. We involved patients from 7 Health Centers in Medan City. We utilised SF 36 instrument to assess the patients quality of lifein the interview. To analyse the collected data, we performed Independent t-analysis. The result of this study was that the quality of life of TB patients who had undergone initial treatment phase wasina low category with a score of 63.9. The two best-measured aspects of quality of life among the eight dimensions assessed in the instrument were pain and physical function.

  7. Perceptual Responses to High- and Moderate-Intensity Interval Exercise in Adolescents.

    PubMed

    Malik, Adam A; Williams, Craig A; Weston, Kathryn L; Barker, Alan R

    2018-05-01

    Continuous high-intensity exercise is proposed to evoke unpleasant sensations as predicted by the dual-mode theory and may negatively impact on future exercise adherence. Previous studies support unpleasant sensations in affective responses during continuous high-intensity exercise, but the affect experience during high-intensity interval exercise (HIIE) involving brief bursts of high-intensity exercise separated by low-intensity activity is poorly understood in adolescents. We examined the acute affective, enjoyment, and perceived exertion responses to HIIE compared with moderate-intensity interval exercise (MIIE) in adolescents. Thirteen adolescent boys (mean ± SD: age, 14.0 ± 0.5 yr) performed two counterbalanced exercise conditions: 1) HIIE: 8 × 1-min work intervals at 90% maximal aerobic speed; and 2) MIIE: between 9 and 12 × 1-min work intervals at 90% ventilatory threshold where the number of intervals performed were distance-matched to HIIE. HIIE and MIIE work intervals were interspersed with 75 s active recovery at 4 km·h. Affect, enjoyment, and RPE were recorded before, during, and after exercise. Affect responses declined in both conditions but the fall was greater in HIIE than MIIE (P < 0.025, effect size [ES], 0.64 to 0.81). Affect remained positive at the end-work interval for both conditions (MIIE, 2.62 ± 1.50; HIIE, 1.15 ± 2.08 on feeling scale). No enjoyment differences were evident during HIIE and MIIE (P = 0.32), but HIIE elicited greater postexercise enjoyment compared with MIIE (P = 0.01, ES = 0.47). RPE was significantly higher during HIIE than MIIE across all work intervals (all P < 0.03, ES > 0.64). Despite elevated RPE, HIIE did not elicit prominent unpleasant feelings as predicted by the dual-mode theory and was associated with greater postexercise enjoyment responses than MIIE. This study demonstrates the feasibility of the application of HIIE as an alternative form of physical activity in adolescents.

  8. Pulsed x-ray imaging of high-density objects using a ten picosecond high-intensity laser driver

    NASA Astrophysics Data System (ADS)

    Rusby, D. R.; Brenner, C. M.; Armstrong, C.; Wilson, L. A.; Clarke, R.; Alejo, A.; Ahmed, H.; Butler, N. M. H.; Haddock, D.; Higginson, A.; McClymont, A.; Mirfayzi, S. R.; Murphy, C.; Notley, M.; Oliver, P.; Allott, R.; Hernandez-Gomez, C.; Kar, S.; McKenna, P.; Neely, D.

    2016-10-01

    Point-like sources of X-rays that are pulsed (sub nanosecond), high energy (up to several MeV) and bright are very promising for industrial and security applications where imaging through large and dense objects is required. Highly penetrating X-rays can be produced by electrons that have been accelerated by a high intensity laser pulse incident onto a thin solid target. We have used a pulse length of 10ps to accelerate electrons to create a bright x-ray source. The bremsstrahlung temperature was measured for a laser intensity from 8.5-12×1018 W/cm2. These x-rays have sequentially been used to image high density materials using image plate and a pixelated scintillator system.

  9. Trends in Use of High-Intensity Statin Therapy After Myocardial Infarction, 2011 to 2014.

    PubMed

    Rosenson, Robert S; Farkouh, Michael E; Mefford, Matthew; Bittner, Vera; Brown, Todd M; Taylor, Ben; Monda, Keri L; Zhao, Hong; Dai, Yuling; Muntner, Paul

    2017-06-06

    Data prior to 2011 suggest that a low percentage of patients hospitalized for acute coronary syndromes filled high-intensity statin prescriptions upon discharge. Black-box warnings, generic availability of atorvastatin, and updated guidelines may have resulted in a change in high-intensity statin use. The aim of this study was to examine trends and predictors of high-intensity statin use following hospital discharge for myocardial infarction (MI) between 2011 and 2014. Secular trends in high-intensity statin use following hospital discharge for MI were analyzed among patients 19 to 64 years of age with commercial health insurance in the MarketScan database (n = 42,893) and 66 to 75 years of age with U.S. government health insurance through Medicare (n = 75,096). Patients filling statin prescriptions within 30 days of discharge were included. High-intensity statins included atorvastatin 40 or 80 mg and rosuvastatin 20 or 40 mg. The percentage of beneficiaries whose first statin prescriptions filled following hospital discharge for MI were for high-intensity doses increased from 33.5% in January through March 2011 to 71.7% in October through November 2014 in MarketScan and from 24.8% to 57.5% in Medicare. Increases in high-intensity statin use following hospital discharge occurred over this period among patients initiating treatment (30.6% to 72.0% in MarketScan and 21.1% to 58.8% in Medicare) and those taking low- or moderate-intensity statins prior to hospitalization (from 27.8% to 62.3% in MarketScan and from 12.6% to 45.1% in Medicare). In 2014, factors associated with filling high-intensity statin prescriptions included male sex, filling beta-blocker and antiplatelet agent prescriptions, and attending cardiac rehabilitation within 30 days following discharge. The use of high-intensity statins following hospitalization for MI increased progressively from 2011 through 2014. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier

  10. The correlation of pain intensity and quality of life in chronic LBP patients in Adam Malik general hospital

    NASA Astrophysics Data System (ADS)

    Nasution, I. K.; Lubis, N. D. A.; Amelia, S.; Hocin, K.

    2018-03-01

    Low back pain (LBP) is a world health problems and a major cause of disability. The study is to determine the correlation between pain intensity and quality of life (QoL) in patients with chronic LBP. This study was a descriptive, analytical research with the cross sectional design. Twenty-nine chronic LBP outpatients that have visited the Neurology Clinic of Adam Malik General Hospital Medan. Patients from July to November 2015 were selected by consecutive sampling. A questionnaire and interview are asking the information about subjects’ characteristics, diagnosis, medical history, pain intensity and quality of life-based on WHO QoL criteria were used to collect the data. Using Spearman correlation test, we found correlation among VAS and physical function (p<0.001, r=-0.606), limitations due to physical problems (p<0.001, r=-0.837), limitations due to emotional problems (p=0.007, r=-0,477), vitality (p=0.021, r=-0.380), social function (p=0.015, r=-0.403), the feeling of pain (p=0.003, r=-0.499) and general health (p=0.040, r=-0.330). On the other hand, there was no correlation between VAS and mental health (p=0.110, r=-0.235). We concluded that pain intensity in outpatients with chronic LBP in the Neurology Clinic at Adam Malik General Hospital Medan correlates with the patients’ quality of life.

  11. Human Milk Management Redesign: Improving Quality and Safety and Reducing Neonatal Intensive Care Unit Nurse Stress.

    PubMed

    Settle, Margaret Doyle; Coakley, Amanda Bulette; Annese, Christine Donahue

    2017-02-01

    Human milk provides superior nutritional value for infants in the neonatal intensive care unit and is the enteral feeding of choice. Our hospital used the system engineering initiative for patient safety model to evaluate the human milk management system in our neonatal intensive care unit. Nurses described the previous process in a negative way, fraught with opportunities for error, increased stress for nurses, and the need to be away from the bedside and their patients. The redesigned process improved the quality and safety of human milk management and created time for the nurses to spend with their patients.

  12. Case management for high-intensity service users: towards a relational approach to care co-ordination.

    PubMed

    McEvoy, Phil; Escott, Diane; Bee, Penny

    2011-01-01

    This study is based on a formative evaluation of a case management service for high-intensity service users in Northern England. The evaluation had three main purposes: (i) to assess the quality of the organisational infrastructure; (ii) to obtain a better understanding of the key influences that played a role in shaping the development of the service; and (iii) to identify potential changes in practice that may help to improve the quality of service provision. The evaluation was informed by Gittell's relational co-ordination theory, which focuses upon cross-boundary working practices that facilitate task integration. The Assessment of Chronic Illness Care Survey was used to assess the organisational infrastructure and qualitative interviews with front line staff were conducted to explore the key influences that shaped the development of the service. A high level of strategic commitment and political support for integrated working was identified. However, the quality of care co-ordination was variable. The most prominent operational factor that appeared to influence the scope and quality of care co-ordination was the pattern of interaction between the case managers and their co-workers. The co-ordination of patient care was much more effective in integrated co-ordination networks. Key features included clearly defined, task focussed, relational workspaces with interactive forums where case managers could engage with co-workers in discussions about the management of interdependent care activities. In dispersed co-ordination networks with fewer relational workspaces, the case managers struggled to work as effectively. The evaluation concluded that the creation of flexible and efficient task focused relational workspaces that are systemically managed and adequately resourced could help to improve the quality of care co-ordination, particularly in dispersed networks. © 2010 Blackwell Publishing Ltd.

  13. Impact of high-intensity interval training and moderate-intensity continuous training on resting and postexercise cardiac troponin T concentration.

    PubMed

    Nie, Jinlei; Zhang, Haifeng; Kong, Zhaowei; George, Keith; Little, Jonathan P; Tong, Tomas K; Li, Feifei; Shi, Qingde

    2018-03-01

    What is the central question of this study? Does exercise training impact resting and postexercise cardiac troponin T (cTnT) concentration? What is the main finding and its importance? This randomized controlled intervention study demonstrated that 12 weeks of either high-intensity interval training or moderate-intensity continuous training largely abolished the exercise-induced elevation in cTnT when exercise was performed at the same absolute intensity. There was no impact of training on resting cTnT or postexercise appearance of cTnT when exercise was performed at the same relative intensity. These findings provide new information that might help clinicians with decision-making in relationship to basal and postexercise values of cTnT in individuals with different training status. We evaluated the influence of 12 weeks of high-intensity interval training [HIIT; repeated 4 min cycling at 90% of maximal oxygen uptake (V̇O2max) interspersed with 3 min rest, 200-300 kJ per session, 3 or 4 days each week] and work-equivalent moderate-intensity continuous training (MICT; continuous cycling at 60% V̇O2max) on resting cardiac troponin T (cTnT) and the appearance of exercise-induced cTnT. Forty-eight sedentary obese young women were randomly assigned to HIIT, MICT or a control group. The V̇O2max and body composition were measured before and after training. At baseline, cTnT was assessed using a high-sensitivity assay at rest and immediately, 2 and 4 h after 45 min cycling at 60% V̇O2max. After a 12 week training period, cTnT was assessed before and after 45 min cycling at the same relative and absolute intensities as before training. Training led to higher V̇O2max and lower fat mass in both HIIT and MICT groups (all P < 0.05). Before training, cTnT was significantly elevated in all three groups (by 35-118%, all P < 0.05) with acute exercise. After training, both resting and postexercise cTnT concentrations (same relative intensity) were similar to

  14. High temperature, high intensity solar array. [for Venus Radar Mapper mission

    NASA Technical Reports Server (NTRS)

    Smith, B. S.; Brooks, G. R.; Pinkerton, R.

    1985-01-01

    The solar array for the Venus Radar Mapper mission will operate in the high temperature, high intensity conditions of a low Venus orbit environment. To fulfill the performance requirements in this environment at minimum cost and mass while maximizing power density and packing factor on the panel surface, several features were introduced into the design. These features included the use of optical surface reflectors (OSR's) to reduce the operating temperature; new adhesives for conductive bonding of OSR's to avoid electrostatic discharges; custom-designed large area cells and novel shunt diode circuit and panel power harness configurations.

  15. Low-volume high-intensity swim training is superior to high-volume low-intensity training in relation to insulin sensitivity and glucose control in inactive middle-aged women.

    PubMed

    Connolly, Luke J; Nordsborg, Nikolai B; Nyberg, Michael; Weihe, Pál; Krustrup, Peter; Mohr, Magni

    2016-10-01

    We tested the hypothesis that low-volume high-intensity swimming has a larger impact on insulin sensitivity and glucose control than high-volume low-intensity swimming in inactive premenopausal women with mild hypertension. Sixty-two untrained premenopausal women were randomised to an inactive control (n = 20; CON), a high-intensity low-volume (n = 21; HIT) or a low-intensity high-volume (n = 21; LIT) training group. During the 15-week intervention period, HIT performed 3 weekly 6-10 × 30-s all-out swimming intervals (average heart rate (HR) = 86 ± 3 % HRmax) interspersed by 2-min recovery periods and LIT swam continuously for 1 h at low intensity (average HR = 73 ± 3 % HRmax). Fasting blood samples were taken and an oral glucose tolerance test (OGTT) was conducted pre- and post-intervention. After HIT, resting plasma [insulin] was lowered (17 ± 34 %; P < 0.05) but remained similar after LIT and CON. Following HIT, 60-min OGTT plasma [insulin] and [glucose] was lowered (24 ± 30 % and 10 ± 16 %; P < 0.05) but remained similar after LIT and CON. Total area under the curve for plasma [glucose] was lower (P < 0.05) after HIT than LIT (660 ± 141 vs. 860 ± 325 mmol min L(-1)). Insulin sensitivity (HOMA-IR) had increased (P < 0.05) by 22 ± 34 % after HIT, with no significant change after LIT or CON, respectively. Plasma soluble intracellular cell adhesion molecule 1 was lowered (P < 0.05) by 4 ± 8 and 3 ± 9 % after HIT and CON, respectively, while plasma soluble vascular cell adhesion molecule 1 had decreased (P < 0.05) by 8 ± 23 % after HIT only. These findings suggest that low-volume high-intensity intermittent swimming is an effective and time-efficient training strategy for improving insulin sensitivity, glucose control and biomarkers of vascular function in inactive, middle-aged mildly hypertensive women.

  16. Acute effects of high- and low-intensity exercise bouts on leukocyte counts.

    PubMed

    Neves, Pedro Rogério Da Silva; Tenório, Thiago Ricardo Dos Santos; Lins, Tatiana Acioli; Muniz, Maria Tereza Cartaxo; Pithon-Curi, Tânia Cristina; Botero, João Paulo; Do Prado, Wagner Luiz

    2015-06-01

    It is widely accepted that physical exercise may bring about changes in the immune system. Even acute bouts of exercise can alter the number and function of leukocytes, but the degree of white blood cell trafficking depends on the intensity and duration of exercise. The aim of this study was to analyze the acute and short-term effects of exercise intensity on leukocyte counts and leukocyte subsets. Nine physically healthy, active young males (21.0 ± 1.9 years) underwent three experimental trials: high exercise intensity [80% peak oxygen consumption (VO 2peak )], low exercise intensity (40% VO 2peak ), and the control condition (no exercise). Blood samples were collected prior to exercise, immediately after exercise, and 2 hours after exercise. Two-way analysis of variance for repeated measures was used to evaluate differences between the trials and the time-points, and to compare times within trials. There was a greater increase in the leukocyte count after high-intensity exercise, compared to the control condition ( p  < 0.01) and low-intensity exercise ( p  < 0.01). This effect was still present 2 hours after passive recovery ( p  < 0.01). When the same participants were submitted to different exercise intensities, the acute and short-term effects of exercise on white blood cells were intensity-dependent immediately after exercise (i.e., lymphocytosis and monocytosis) and 2 hours after passive recovery (i.e., neutrophilia).

  17. Applications of High Intensity Proton Accelerators

    NASA Astrophysics Data System (ADS)

    Raja, Rajendran; Mishra, Shekhar

    2010-06-01

    Superconducting radiofrequency linac development at Fermilab / S. D. Holmes -- Rare muon decay experiments / Y. Kuno -- Rare kaon decays / D. Bryman -- Muon collider / R. B. Palmer -- Neutrino factories / S. Geer -- ADS and its potential / J.-P. Revol -- ADS history in the USA / R. L. Sheffield and E. J. Pitcher -- Accelerator driven transmutation of waste: high power accelerator for the European ADS demonstrator / J. L. Biarrotte and T. Junquera -- Myrrha, technology development for the realisation of ADS in EU: current status & prospects for realisation / R. Fernandez ... [et al.] -- High intensity proton beam production with cyclotrons / J. Grillenberger and M. Seidel -- FFAG for high intensity proton accelerator / Y. Mori -- Kaon yields for 2 to 8 GeV proton beams / K. K. Gudima, N. V. Mokhov and S. I. Striganov -- Pion yield studies for proton driver beams of 2-8 GeV kinetic energy for stopped muon and low-energy muon decay experiments / S. I. Striganov -- J-Parc accelerator status and future plans / H. Kobayashi -- Simulation and verification of DPA in materials / N. V. Mokhov, I. L. Rakhno and S. I. Striganov -- Performance and operational experience of the CNGS facility / E. Gschwendtner -- Particle physics enabled with super-conducting RF technology - summary of working group 1 / D. Jaffe and R. Tschirhart -- Proton beam requirements for a neutrino factory and muon collider / M. S. Zisman -- Proton bunching options / R. B. Palmer -- CW SRF H linac as a proton driver for muon colliders and neutrino factories / M. Popovic, C. M. Ankenbrandt and R. P. Johnson -- Rapid cycling synchrotron option for Project X / W. Chou -- Linac-based proton driver for a neutrino factory / R. Garoby ... [et al.] -- Pion production for neutrino factories and muon colliders / N. V. Mokhov ... [et al.] -- Proton bunch compression strategies / V. Lebedev -- Accelerator test facility for muon collider and neutrino factory R&D / V. Shiltsev -- The superconducting RF linac for muon

  18. High intensity focused ultrasound (HIFU) in tumor therapy.

    PubMed

    Sequeiros, Roberto Blanco; Joronen, Kirsi; Komar, Gaber; Koskinen, Seppo K

    HIFU (high intensity focused ultrasound) is a method in which high-frequency ultrasound is focused on a tissue in order to achieve a thermal effect and the subsequent percutaneously ablation, or tissue modulation. HIFU is non-invasive and results in an immediate tissue destruction effect corresponding to surgery, either percutaneously or through body cavities. HIFU can be utilized in the treatment of both benign and malignant tumors. In neurological diseases, focused HIFU can be used in the treatment of disorders of the basal ganglia.

  19. A Highly intense DC muon source, MuSIC and muon CLFV search

    NASA Astrophysics Data System (ADS)

    Hino, Y.; Kuno, Y.; Sato, A.; Sakamoto, H.; Matsumoto, Y.; Tran, N. H.; Hashim, I. H.; Fukuda, M.; Hayashida, Y.; Ogitsu, T.; Yamamoto, A.; Yoshida, M.

    2014-08-01

    MuSIC is a new muon facility, which provides the world's highest intense muon beam with continuous time structure at Research Center of Nuclear Physics (RCNP), Osaka University. It's intensity is designed to be 108 muons per second with only 0.4 kW proton beam. Such a high intense muon beam is very important for searches of rare decay processes, for example search for the muon to electron conversion.

  20. High intensity positron source at HFR: Basic concept, scoring and design optimisation

    NASA Astrophysics Data System (ADS)

    Zeman, A.; Tuček, K.; Debarberis, L.; Hogenbirk, A.

    2012-01-01

    Recent applications of positron beam techniques in various fields of research have led to an increasing demand for high intensity positron sources required for advanced applications, particularly in materials science. Considerable efforts are being made worldwide to design and set-up high intensity positron sources and beam systems that are based on several principles. Such positron sources could be used in fundamental and applied research experiments, as well as in industrial applications, especially in the field of condensed matter characterisation at the nanometre scale. Phenomena involving positrons are also important in other applied science fields such as medicine, biology, physics, energy, etc. However, such studies are often limited due to the relative lack of suitable positron sources. Results from the recently completed Exploratory Research Project called "HIPOS" are discussed in this paper, which describes the principles behind such a powerful very high intensity positron beam experimental facility that is based on a reactor source. Details of a proposed concept that uses nuclear reactions [(n, γ) and (γ, pair)] within a designed positron generator at the High Flux Reactor (HFR) in Petten are also discussed. The HIPOS source has been designed to produce slow positrons with intensity of the order of 10 10 e +/s.

  1. Using antibrowning agents to enhance quality and safety of fresh-cut avocado treated with intense light pulses.

    PubMed

    Ramos-Villarroel, Ana Y; Martín-Belloso, Olga; Soliva-Fortuny, Robert

    2011-01-01

    The effect of antibrowning compounds on the color and firmness of fresh-cut avocado treated with intense light pulses (ILP), as well as their impact on the survival of Listeria innocua, was investigated in this study. Dipping solutions containing 2% (w/v) L-cysteine without ascorbic acid and combined with 1% (w/v) citric acid and 1% w/v calcium lactate most effectively preserved the initial color and texture of ILP-treated fresh-cut avocado. On the other hand, ILP treatments caused a reduction of more than 3 log cycles in the populations of L. innocua inoculated on fresh-cut avocado. Log reduction levels increased when antibrowning agents were combined with ILP treatments. In conclusion, the use of quality-stabilizing agents is a good option to guarantee both the microbiological safety of fresh-cut avocado treated with ILP as well as to improve its physical and chemical quality. Intense light pulses (ILP) have received considerable attention during the last years after its approval by the U.S. Food and Drug Administration (FDA) in 1996 as a decontamination method for food or food surfaces. This article presents relevant information regarding the effect of ILP treatments combined with quality-stabilizing compounds as a feasible alternative to improve the physical and chemical quality of fresh-cut avocado as well as to guarantee its microbiological safety. © 2011 Institute of Food Technologists®

  2. High-intensity exercise interventions in cancer survivors: a systematic review exploring the impact on health outcomes.

    PubMed

    Toohey, Kellie; Pumpa, Kate; McKune, Andrew; Cooke, Julie; Semple, Stuart

    2018-01-01

    There is an increasing body of evidence underpinning high-intensity exercise as an effective and time-efficient intervention for improving health in cancer survivors. The aim of this study was to, (1) evaluate the efficacy and (2) the safety of high-intensity exercise interventions in improving selected health outcomes in cancer survivors. Design Systematic review. Data sources Google Scholar and EBSCO, CINAHL Plus, Computers and Applied Sciences Complete, Health Source-Consumer Edition, Health Source: Nursing/Academic Edition, MEDLINE, Web of Science and SPORTDiscuss from inception up until August 2017. Eligibility criteria Randomized controlled trials of high-intensity exercise interventions in cancer survivors (all cancer types) with health-related outcome measures. The guidelines adopted for this review were the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA). The search returned 447 articles, of which nine articles (n = 531 participants mean, age 58 ± 9.5 years) met the eligibility criteria. Exercise interventions of between 4 and 18 weeks consisting of high-intensity interval bouts of up to 4-min were compared with a continuous moderate intensity (CMIT) intervention or a control group. High-intensity exercise interventions elicited significant improvements in VO 2 max, strength, body mass, body fat and hip and waist circumference compared with CMIT and/or control groups. The studies reviewed showed low risk in participating in supervised high-intensity exercise interventions. Mixed mode high-intensity interventions which included both aerobic and resistance exercises were most effective improving the aerobic fitness levels of cancer survivors by 12.45-21.35%, from baseline to post-intervention. High-intensity exercise interventions improved physical and physiological health-related outcome measures such as cardiovascular fitness and strength in cancer survivors. Given that high-intensity exercise sessions require a

  3. Liquid lithium target as a high intensity, high energy neutron source

    DOEpatents

    Parkin, Don M.; Dudey, Norman D.

    1976-01-01

    This invention provides a target jet for charged particles. In one embodiment the charged particles are high energy deuterons that bombard the target jet to produce high intensity, high energy neutrons. To this end, deuterons in a vacuum container bombard an endlessly circulating, free-falling, sheet-shaped, copiously flowing, liquid lithium jet that gushes by gravity from a rectangular cross-section vent on the inside of the container means to form a moving web in contact with the inside wall of the vacuum container. The neutrons are produced via break-up of the beam in the target by stripping, spallation and compound nuclear reactions in which the projectiles (deuterons) interact with the target (Li) to produce excited nuclei, which then "boil off" or evaporate a neutron.

  4. High-intensity positron microprobe at the Thomas Jefferson National Accelerator Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Golge, S., E-mail: serkan.golge@nasa.gov; Vlahovic, B.; Wojtsekhowski, B.

    We present a conceptual design for a novel continuous wave electron-linac based high-intensity high-brightness slow-positron production source with a projected intensity on the order of 10{sup 10 }e{sup +}/s. Reaching this intensity in our design relies on the transport of positrons (T{sub +} below 600 keV) from the electron-positron pair production converter target to a low-radiation and low-temperature area for moderation in a high-efficiency cryogenic rare gas moderator, solid Ne. This design progressed through Monte Carlo optimizations of: electron/positron beam energies and converter target thickness, transport of the e{sup +} beam from the converter to the moderator, extraction of the e{sup +}more » beam from the magnetic channel, a synchronized raster system, and moderator efficiency calculations. For the extraction of e{sup +} from the magnetic channel, a magnetic field terminator plug prototype has been built and experimental results on the effectiveness of the prototype are presented. The dissipation of the heat away from the converter target and radiation protection measures are also discussed.« less

  5. James Clerk Maxwell Prize Address: High Intensity Laser Propagation and Interactions

    NASA Astrophysics Data System (ADS)

    Sprangle, Phillip

    2013-10-01

    High intensity laser radiation sources cover a wide range of parameters, e.g., peak powers from tera to peta watts, pulse lengths from pico to femto seconds, repetition rates ranging from kilo to mega hertz and average powers of many tens of watts. This talk will cover, among other things, some of the unique physical processes which result when high intensity laser radiation interacts with gases and plasmas. One of the interesting topics to be discussed is the propagation of these laser pulses in a turbulent atmosphere which results in a multitude of coupled linear and nonlinear processes including filamentation and scintillation. Phase conjugation techniques to reduce the effects of atmospheric turbulence (scintillation) will be described. This talk will also discuss a range of potential applications of these high intensity lasers, including: electron acceleration in spatially periodic and tapered plasma channels, detection of radioactive material using electromagnetic signatures, atmospheric lasing of N2 molecules, as well as incoherent and coherent x-ray generation mechanisms. Research supported by NRL, ONR and UMD.

  6. Oxidative stress does not influence local sweat rate during high-intensity exercise.

    PubMed

    Meade, Robert D; Fujii, Naoto; Poirier, Martin P; Boulay, Pierre; Sigal, Ronald J; Kenny, Glen P

    2018-02-01

    What is the central question of this study? We evaluated whether oxidative stress attenuates the contribution of nitric oxide to sweating during high-intensity exercise. What is the main finding and its importance? In contrast to our previous report of an oxidative stress-mediated reduction in nitric oxide-dependent cutaneous vasodilatation in this cohort during intense exercise, we demonstrated no influence of local ascorbate administration on the sweating response during moderate- (∼51% peak oxygen uptake) or high-intensity exercise (∼72% peak oxygen uptake). These new findings provide important mechanistic insight into how exercise-induced oxidative stress impacts sudomotor activity. Nitric oxide (NO)-dependent sweating is diminished during high- but not moderate-intensity exercise. We evaluated whether this impairment stems from increased oxidative stress during high-intensity exercise. On two separate days, 11 young (24 ± 4 years) men cycled in the heat (35°C) at a moderate [500 W; 52 ± 6% peak oxygen uptake (V̇O2 peak )] or high (700 W; 71 ± 5% V̇O2 peak ) rate of metabolic heat production. Each session included two 30 min exercise bouts separated by a 20 min recovery period. Local sweat rate was monitored at four forearm skin sites continuously perfused via intradermal microdialysis with the following: (i) lactated Ringer solution (Control); (ii) 10 mm ascorbate (Ascorbate; non-selective antioxidant); (iii) 10 mm N G -nitro-l-arginine methyl ester (l-NAME; NO synthase inhibitor); or (iv) 10 mm ascorbate plus 10 mm l-NAME (Ascorbate + l-NAME). During moderate exercise, sweat rate was attenuated at the l-NAME and Ascorbate + l-NAME sites (both ∼1.0 mg min -1  cm -2 ; all P < 0.05) but not at the Ascorbate site (∼1.1 mg min -1  cm -2 ; both P ≥ 0.28) in comparison to the Control site (∼1.1 mg min -1  cm -2 ). However, no differences were observed between treatment sites (∼1.4 mg min -1  cm -2 ; P = 0

  7. A comparative study of occupancy and patient care quality in four different types of intensive care units in a children's hospital.

    PubMed

    Smith, Thomas J

    2012-01-01

    This paper reports a comparative study of occupancy and patient care quality in four types of intensive care units in a children's hospital,: an Infant Care Center (ICC), a Medical/Surgical (Med/Surg) unit, a Neonatal Intensive Care Unit (NICU), and a Pediatric Intensive Care Unit (PICU), each featuring a mix of multi-bed and private room (PR) patient care environments. The project is prompted by interest by the project sponsor in a pre-occupancy analysis, before the units are upgraded to exclusive PR designs. Methods comprised, for each unit: (1) observations of ergonomic design features; (2) task activity analyses of job performance of selected staff; and (3) use of a survey to collect perceptions by unit nursing and house staff (HS) of indicators of occupancy and patient care quality. (1) the five most common task activities are interaction with patients, charting, and interaction with equipment, co-workers and family members; (2) job satisfaction, patient care, work environment, job, patient care team interaction, and general occupancy quality rankings by ICC and/or NICU respondents are significantly higher than those by other staff respondents; and (3) ergonomic design shortcomings noted are excess noise, problems with equipment, and work environment, job-related health, and patient care quality issues.

  8. Evaluating intervention fidelity: an example from a high-intensity interval training study.

    PubMed

    Taylor, Kathryn L; Weston, Matthew; Batterham, Alan M

    2015-01-01

    Intervention fidelity refers to the degree to which an experimental manipulation has been implemented as intended, but simple, robust methods for quantifying fidelity have not been well documented. Therefore, we aim to illustrate a rigorous quantitative evaluation of intervention fidelity, using data collected during a high-intensity interval training intervention. Single-group measurement study. Seventeen adolescents (mean age ± standard deviation [SD] 14.0 ± 0.3 years) attended a 10-week high-intensity interval training intervention, comprising two exercise sessions per week. Sessions consisted of 4-7 45-s maximal effort repetitions, interspersed with 90-s rest. We collected heart rate data at 5-s intervals and recorded the peak heart rate for each repetition. The high-intensity exercise criterion was ≥ 90% of individual maximal heart rate. For each participant, we calculated the proportion of total exercise repetitions exceeding this threshold. A linear mixed model was applied to properly separate the variability in peak heart rate between- and within-subjects. Results are presented both as intention to treat (including missed sessions) and per protocol (only participants with 100% attendance; n=8). For intention to treat, the median (interquartile range) proportion of repetitions meeting the high-intensity criterion was 58% (42% to 68%). The mean peak heart rate was 85% of maximal, with a between-subject SD of 7.8 (95% confidence interval 5.4 to 11.3) percentage points and a within-subject SD of 15.1 (14.6 to 15.6) percentage points. For the per protocol analysis, the median proportion of high-intensity repetitions was 68% (47% to 86%). The mean peak heart rate was 91% of maximal, with between- and within-subject SDs of 3.1 (-1.3 to 4.6) and 3.4 (3.2 to 3.6) percentage points, respectively. Synthesising information on exercise session attendance and compliance (exercise intensity) quantifies the intervention dose and informs evaluations of treatment

  9. Effect of Intensive Statin Therapy on Coronary High-Intensity Plaques Detected by Noncontrast T1-Weighted Imaging: The AQUAMARINE Pilot Study.

    PubMed

    Noguchi, Teruo; Tanaka, Atsushi; Kawasaki, Tomohiro; Goto, Yoichi; Morita, Yoshiaki; Asaumi, Yasuhide; Nakao, Kazuhiro; Fujiwara, Reiko; Nishimura, Kunihiro; Miyamoto, Yoshihiro; Ishihara, Masaharu; Ogawa, Hisao; Koga, Nobuhiko; Narula, Jagat; Yasuda, Satoshi

    2015-07-21

    Coronary high-intensity plaques detected by noncontrast T1-weighted imaging may represent plaque instability. High-intensity plaques can be quantitatively assessed by a plaque-to-myocardium signal-intensity ratio (PMR). This pilot, hypothesis-generating study sought to investigate whether intensive statin therapy would lower PMR. Prospective serial noncontrast T1-weighted magnetic resonance imaging and computed tomography angiography were performed in 48 patients with coronary artery disease at baseline and after 12 months of intensive pitavastatin treatment with a target low-density lipoprotein cholesterol level <80 mg/dl. The control group consisted of coronary artery disease patients not treated with statins that were matched by propensity scoring (n = 48). The primary endpoint was the 12-month change in PMR. Changes in computed tomography angiography parameters and high-sensitivity C-reactive protein levels were analyzed. In the statin group, 12 months of statin therapy significantly improved low-density lipoprotein cholesterol levels (125 to 70 mg/dl; p < 0.001), PMR (1.38 to 1.11, an 18.9% reduction; p < 0.001), low-attenuation plaque volume, and the percentage of total atheroma volume on computed tomography. In the control group, the PMR increased significantly (from 1.22 to 1.49, a 19.2% increase; p < 0.001). Changes in PMR were correlated with changes in low-density lipoprotein cholesterol (r = 0.533; p < 0.001), high-sensitivity C-reactive protein (r = 0.347; p < 0.001), percentage of atheroma volume (r = 0.477; p < 0.001), and percentage of low-attenuation plaque volume (r = 0.416; p < 0.001). Statin treatment significantly reduced the PMR of high-intensity plaques. Noncontrast T1-weighted magnetic resonance imaging could become a useful technique for repeated quantitative assessment of plaque composition. (Attempts at Plaque Vulnerability Quantification with Magnetic Resonance Imaging Using Noncontrast T1-weighted Technique [AQUAMARINE

  10. Maximum Movement Workloads and High-Intensity Workload Demands by Position in NCAA Division I Collegiate Football.

    PubMed

    Sanders, Gabriel J; Roll, Brad; Peacock, Corey A; Kollock, Roger O

    2018-05-02

    Sanders, GJ, Roll, B, Peacock, CA, and Kollock, RO. Maximum movement workloads and high-intensity workload demands by position in NCAA division I collegiate football. J Strength Cond Res XX(X): 000-000, 2018-The purpose of the study was to quantify the average and maximum (i.e., peak) movement workloads, and the percent of those workloads performed at high intensity by NCAA division I football athletes during competitive games. Using global positioning system devices (Catapult Sports), low, moderate, and high and total multidirectional movement workloads were quantified by each position. Strategically achieving maximal workloads may improve both conditioning and rehabilitation protocols for athletes as they prepare for competition or return to play after an injury. A total of 40 football athletes were included in the analysis. For the data to be included, athletes were required to participate in ≥75% of the offensive or defensive snaps for any given game. There was a total of 286 data downloads from 13 different games for 8 different football positions. Data were calculated and compared by offensive and defensive position to establish the mean, SD, and maximum workloads during competitive games. The percent high-intensity workload profile was established to assess the total number and percent of high-intensity movement workloads by position. The profile was calculated by dividing a position's maximal high-intensity movement workload by the total (e.g., sum of maximal low, moderate, and high-intensity movements) movement workload. One-way analysis of variances revealed that there was a main effect of football position for total movement workloads and the percent of workloads performed at high intensities (p ≤ 0.025 for all). Maximal high-intensity workloads were 1.6-4.3 times greater than average high-intensity workloads, and the percent of total workloads performed at high intensities varied greatly by position. Strategically training for and using maximal

  11. Soil hydraulic characteristics of a small southwest Oregon watershed following high-intensity wildfires

    Treesearch

    David S. Parks; Terrance W. Cundy

    1989-01-01

    The Angel Fire of September, 1987 caused extensive damage to second growth forest in the south fork drainage of Cow Creek, 55 km northeast of Grant's Pass, Oregon, USA. The fire was characterized by a high-intensity burn over areas of steep topography. The areal distribution of soil hydraulic properties in a small, tributary watershed following high-intensity...

  12. Odour intensity learning in fruit flies

    PubMed Central

    Yarali, Ayse; Ehser, Sabrina; Hapil, Fatma Zehra; Huang, Ju; Gerber, Bertram

    2009-01-01

    Animals' behaviour towards odours depends on both odour quality and odour intensity. While neuronal coding of odour quality is fairly well studied, how odour intensity is treated by olfactory systems is less clear. Here we study odour intensity processing at the behavioural level, using the fruit fly Drosophila melanogaster. We trained flies by pairing a MEDIUM intensity of an odour with electric shock, and then, at a following test phase, measured flies' conditioned avoidance of either this previously trained MEDIUM intensity or a LOWer or a HIGHer intensity. With respect to 3-octanol, n-amylacetate and 4-methylcyclohexanol, we found that conditioned avoidance is strongest when training and test intensities match, speaking for intensity-specific memories. With respect to a fourth odour, benzaldehyde, on the other hand, we found no such intensity specificity. These results form the basis for further studies of odour intensity processing at the behavioural, neuronal and molecular level. PMID:19586944

  13. SU-E-T-617: Plan Quality Estimation of Intensity-Modulated Radiotherapy Cases for Lung Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koo, J; Yoon, M; Chung, W

    Purpose: To estimate the planning quality of intensity-modulated radiotherapy in lung cancer cases and to provide preliminary data for the development of a planning quality assurance algorithm. Methods: 42 IMRT plans previously used in cases of solitary lung cancers were collected. Organs in or near the thoracic cavity, such as lung (ipsilateral, contralateral), heart, liver, esophagus, cord and bronchus were considered as organs at risk (OARs) in this study. The coverage index (CVI), conformity index (CI), homogeneity index (HI), volume, irregularity (standard deviation of center-surface distance) were used to compare PTV dose characteristics. The effective uniform dose (EUD), V10Gy, andmore » V20Gy of the OARs were used to compare OAR dose characteristics. Results: Average CVI, CI, HI values were 0.9, 0.8, 0.1, respectively. CVI and CI had narrow Gaussian distribution curves without a singular value, but one case had a relatively high (0.25) HI because of location and irregular shape (Irregularity of 18.5 when average was 12.5) of PTV. EUDs tended to decrease as OAR-PTV distance increased and OAR-PTV overlap volume decreased. Conclusion: This work indicates the potential for significant plan quality deviation of similar lung cancer cases. Considering that this study were from a single department, differences in the treatment results for a given patient would be much more pronounced if multiple departments (and therefore more planners) were involved. Therefore, further examination of QA protocols is needed to reduce deviations in radiation treatment planning.« less

  14. Age-Related Changes in Associations Between Reasons for Alcohol Use and High-Intensity Drinking Across Young Adulthood.

    PubMed

    Patrick, Megan E; Evans-Polce, Rebecca; Kloska, Deborah D; Maggs, Jennifer L; Lanza, Stephanie T

    2017-07-01

    Analyses focus on whether self-reported reasons for drinking alcohol change in their associations with high-intensity drinking across the transition to adulthood. Self-report data on high-intensity drinking (10+ drinks) collected from the national Monitoring the Future study in 2005 to 2014 from those ages 18-26 were used (N = 2,664 [60% women] for all drinkers and 1,377 for heavy episodic [5+] drinkers; up to 6,541 person-waves). Time-varying effect modeling examined changes in the direction and magnitude of associations between eight reasons for drinking and high-intensity alcohol use across continuous age. Four reasons to drink showed quite stable associations with high-intensity drinking across age: drinking to get away from problems, to get high, to relax, and to sleep. Associations between two reasons and high-intensity drinking decreased with age: anger/frustration and to have a good time. The association between drinking because of boredom and high-intensity drinking increased with age. Drinking because it tastes good had a weak association with high-intensity drinking. Among heavy episodic drinkers, reasons for use also differentiated high-intensity drinking, with two exceptions: drinking to have a good time and to relax did not distinguish drinking 10+ drinks from drinking 5-9 drinks. Reasons for drinking are differentially associated with high-intensity drinking, compared with any other drinking and compared with lower intensity heavy drinking, across age during the transition to adulthood. Intervention programs seeking to mitigate alcohol-related harms should focus on reasons for use when they are the most developmentally salient.

  15. Simple, inexpensive technique for high-quality smartphone fundus photography in human and animal eyes.

    PubMed

    Haddock, Luis J; Kim, David Y; Mukai, Shizuo

    2013-01-01

    Purpose. We describe in detail a relatively simple technique of fundus photography in human and rabbit eyes using a smartphone, an inexpensive app for the smartphone, and instruments that are readily available in an ophthalmic practice. Methods. Fundus images were captured with a smartphone and a 20D lens with or without a Koeppe lens. By using the coaxial light source of the phone, this system works as an indirect ophthalmoscope that creates a digital image of the fundus. The application whose software allows for independent control of focus, exposure, and light intensity during video filming was used. With this app, we recorded high-definition videos of the fundus and subsequently extracted high-quality, still images from the video clip. Results. The described technique of smartphone fundus photography was able to capture excellent high-quality fundus images in both children under anesthesia and in awake adults. Excellent images were acquired with the 20D lens alone in the clinic, and the addition of the Koeppe lens in the operating room resulted in the best quality images. Successful photodocumentation of rabbit fundus was achieved in control and experimental eyes. Conclusion. The currently described system was able to take consistently high-quality fundus photographs in patients and in animals using readily available instruments that are portable with simple power sources. It is relatively simple to master, is relatively inexpensive, and can take advantage of the expanding mobile-telephone networks for telemedicine.

  16. High-quality compressive ghost imaging

    NASA Astrophysics Data System (ADS)

    Huang, Heyan; Zhou, Cheng; Tian, Tian; Liu, Dongqi; Song, Lijun

    2018-04-01

    We propose a high-quality compressive ghost imaging method based on projected Landweber regularization and guided filter, which effectively reduce the undersampling noise and improve the resolution. In our scheme, the original object is reconstructed by decomposing of regularization and denoising steps instead of solving a minimization problem in compressive reconstruction process. The simulation and experimental results show that our method can obtain high ghost imaging quality in terms of PSNR and visual observation.

  17. High intensity surface plasma waves, theory and PIC simulations

    NASA Astrophysics Data System (ADS)

    Raynaud, M.; Héron, A.; Adam, J.-C.

    2018-01-01

    With the development of intense (>1019 W cm-2) short pulses (≤25 fs) laser with very high contrast, surface plasma wave (SPW) can be explored in the relativistic regime. As the SPW propagates with a phase velocity close to the speed of light it may results in a strong acceleration of electron bunches along the surface permitting them to reach relativistic energies. This may be important e.g. for applications in the field of plasma-based accelerators. We investigate in this work the excitation of SPWs on grating preformed over-dense plasmas for laser intensities ranging from 1019 up to 1021 W cm-2. We discuss the nature of the interaction with respect to the solid case in which surface plasmon can be resonantly excited with weak laser intensity. In particular, we show the importance of the pulse duration and focalization of the laser beam on the amplitude of the SPW.

  18. Pubic Bone Osteomyelitis after Salvage High-Intensity Focused Ultrasound for Prostate Cancer

    PubMed Central

    Robison, Christopher M.; Gor, Ronak A.; Metro, Michael J.

    2014-01-01

    High-intensity focused ultrasound can be used for the primary treatment of prostate cancer and biochemical recurrence after radical prostatectomy or radiation. Complications of high-intensity focused ultrasound include urinary retention, urethral stenosis, stress incontinence, urinary tract infections, dysuria, impotence, and rarely, rectourethral or rectovesicular fistula. We describe a patient presenting with urinary retention, urinary tract infections and intermittent stress incontinence, later found to be associated with pubic bone osteomyelitis stemming from a prostatopubic fistula. PMID:24917777

  19. High intensity training in obesity: a Meta‐analysis

    PubMed Central

    Theel, W.; Kasteleyn, M. J.; Franssen, F. M. E.; Hiemstra, P. S.; Rudolphus, A.; Taube, C.; Braunstahl, G. J.

    2017-01-01

    Summary Introduction High Intensity training (HIT) is a time‐effective alternative to traditional exercise programs in adults with obesity, but the superiority in terms of improving cardiopulmonary fitness and weight loss has not been demonstrated. Objective to determine the effectiveness of HIT on cardiopulmonary fitness and body composition in adults with obesity compared to traditional (high volume continuous) exercise. Methods A systematic search of the main health science databases was conducted for randomized controlled trials comparing HIT with traditional forms of exercise in people with obesity. Eighteen studies were included in the meta‐analysis. The (unstandardized) mean difference of each outcome parameters was calculated and pooled with the random effects model. Results HIT resulted in greater improvement of cardiopulmonary fitness (VO2max) (MD 1.83, 95% CI 0.70, 2.96, p<0.005; I2=31%) and a greater reduction of %body fat (MD ‐1.69, 95% CI ‐3.10, ‐0.27, p=0.02, I2=30%) compared to traditional exercise. Overall effect for BMI was not different between HIT and traditional exercise. Conclusion Training at high intensity is superior to improve cardiopulmonary fitness and to reduce %body fat in adults with obesity compared to traditional exercise. Future studies are needed to design specific HIT programs for the obese with regard to optimal effect and long‐term adherence. PMID:29071102

  20. Influence of liquid-volume and airflow rates on spray application quality and homogeneity in super-intensive olive tree canopies.

    PubMed

    Miranda-Fuentes, Antonio; Rodríguez-Lizana, Antonio; Gil, Emilio; Agüera-Vega, J; Gil-Ribes, Jesús A

    2015-12-15

    Olive is a key crop in Europe, especially in countries around the Mediterranean Basin. Optimising the parameters of a spray is essential for sustainable pesticide use, especially in high-input systems, such as the super-intensive hedgerow system. Parameters may be optimised by adjusting the applied volume and airflow rate of sprays, in addition to the liquid to air proportion and the relationship between air velocity and airflow rate. Two spray experiments using a commercial airblast sprayer were conducted in a super-intensive orchard to study how varying the liquid volume rate (testing volumes of 182, 619, and 1603 l ha(-1)) and volumetric airflow rate (with flow rates of 11.93, 8.90, and 6.15 m(3) s(-1)) influences the coverage parameters and the amount and distribution of deposits in different zones of the canopy.. Our results showed that an increase in the application volume raised the mean deposit and percentage coverage, but decreased the application efficiency, spray penetration, and deposit homogeneity. Furthermore, we found that the volumetric airflow rate had a lower influence on the studied parameters than the liquid volume; however, an increase in the airflow rate improved the application efficiency and homogeneity to a certain threshold, after which the spray quality decreased. This decrease was observed in the high-flow treatment. Our results demonstrate that intermediate liquid volume rates and volumetric airflow rates are required for the optimal spraying of pesticides on super-intensive olive crops, and would reduce current pollution levels. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Psychophysiological effects of music on acute recovery from high-intensity interval training.

    PubMed

    Jones, Leighton; Tiller, Nicholas B; Karageorghis, Costas I

    2017-03-01

    Numerous studies have examined the multifarious effects of music applied during exercise but few have assessed the efficacy of music as an aid to recovery. Music might facilitate physiological recovery via the entrainment of respiratory rhythms with music tempo. High-intensity exercise training is not typically associated with positive affective responses, and thus ways of assuaging negative affect warrant further exploration. This study assessed the psychophysiological effects of music on acute recovery and prevalence of entrainment in between bouts of high-intensity exercise. Thirteen male runners (M age =20.2±1.9years; BMI=21.7±1.7; V̇O 2 max=61.6±6.1mL·kg·min -1 ) completed three exercise sessions comprising 5×5-min bouts of high-intensity intervals interspersed with 3-min periods of passive recovery. During recovery, participants were administered positively-valenced music of a slow-tempo (55-65bpm), fast-tempo (125-135bpm), or a no-music control. A range of measures including affective responses, RPE, cardiorespiratory indices (gas exchange and pulmonary ventilation), and music tempo-respiratory entrainment were recorded during exercise and recovery. Fast-tempo, positively-valenced music resulted in higher Feeling Scale scores throughout recovery periods (p<0.01, η p 2 =0.38). There were significant differences in HR during initial recovery periods (p<0.05, η p 2 =0.16), but no other music-moderated differences in cardiorespiratory responses. In conclusion, fast-tempo, positively-valenced music applied during recovery periods engenders a more pleasant experience. However, there is limited evidence that music expedites cardiorespiratory recovery in between bouts of high-intensity exercise. These findings have implications for athletic training strategies and individuals seeking to make high-intensity exercise sessions more pleasant. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Randomized algorithms for high quality treatment planning in volumetric modulated arc therapy

    NASA Astrophysics Data System (ADS)

    Yang, Yu; Dong, Bin; Wen, Zaiwen

    2017-02-01

    In recent years, volumetric modulated arc therapy (VMAT) has been becoming a more and more important radiation technique widely used in clinical application for cancer treatment. One of the key problems in VMAT is treatment plan optimization, which is complicated due to the constraints imposed by the involved equipments. In this paper, we consider a model with four major constraints: the bound on the beam intensity, an upper bound on the rate of the change of the beam intensity, the moving speed of leaves of the multi-leaf collimator (MLC) and its directional-convexity. We solve the model by a two-stage algorithm: performing minimization with respect to the shapes of the aperture and the beam intensities alternatively. Specifically, the shapes of the aperture are obtained by a greedy algorithm whose performance is enhanced by random sampling in the leaf pairs with a decremental rate. The beam intensity is optimized using a gradient projection method with non-monotonic line search. We further improve the proposed algorithm by an incremental random importance sampling of the voxels to reduce the computational cost of the energy functional. Numerical simulations on two clinical cancer date sets demonstrate that our method is highly competitive to the state-of-the-art algorithms in terms of both computational time and quality of treatment planning.

  3. Pathological, Oncologic and Functional Outcomes of a Prospective Registry of Salvage High Intensity Focused Ultrasound Ablation for Radiorecurrent Prostate Cancer.

    PubMed

    Siddiqui, Khurram M; Billia, Michele; Arifin, Andrew; Li, Fan; Violette, Philippe; Chin, Joseph L

    2017-01-01

    In this prospective registry we prospectively assessed the oncologic, functional and safety outcomes of salvage high intensity focused ultrasound for radiorecurrent prostate cancer. A total of 81 men were prospectively recruited and evaluated at regular scheduled study visits to 6 months after high intensity focused ultrasound and thereafter as per standard of care. Transrectal ultrasound guided biopsy was performed at 6 months. The primary end point was absence or histological persistence of disease at 6-month biopsy. Secondary end points included quality of life, biochemical recurrence-free survival, overall survival, cancer specific survival and progression to androgen deprivation therapy. Survival analysis was performed according to the Kaplan-Meier method and multivariate analysis was performed using the log rank (Mantel-Cox) test. Mean ± SD prostate specific antigen before high intensity focused ultrasound was 4.06 ± 2.88 ng/ml. At 6 months 63 men underwent biopsy, of whom 22 (35%) had residual disease. At a mean followup of 53.5 ± 31.6 months median biochemical recurrence-free survival was 63 months. The 5-year overall and cancer specific survival rates were 88% and 94.4%, respectively. Nadir prostate specific antigen less than 0.5 ng/ml was a significant predictor of biochemical recurrence-free survival (p=0.014, 95% CI 1.22-5.87). I-PSS significantly increased (p <0.001) while IIEF-5 scores decreased and the SF-36 score did not change significantly. The rate of rectal fistulization and severe incontinence was 3.7% each. A total of 223 complications were recorded in the 180 days after high intensity focused ultrasound (Clavien-Dindo grade 1-195, grade II-20, grade III-7, grade IVa-1). Salvage high intensity focused ultrasound appears to be a viable treatment option for radiorecurrent prostate cancer, with acceptable morbidity. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  4. An operations-partnered evaluation of care redesign for high-risk patients in the Veterans Health Administration (VHA): Study protocol for the PACT Intensive Management (PIM) randomized quality improvement evaluation.

    PubMed

    Chang, Evelyn T; Zulman, Donna M; Asch, Steven M; Stockdale, Susan E; Yoon, Jean; Ong, Michael K; Lee, Martin; Simon, Alissa; Atkins, David; Schectman, Gordon; Kirsh, Susan R; Rubenstein, Lisa V

    2018-06-01

    Patient-centered medical homes have made great strides providing comprehensive care for patients with chronic conditions, but may not provide sufficient support for patients at highest risk for acute care use. To address this, the Veterans Health Administration (VHA) initiated a five-site demonstration project to evaluate the effectiveness of augmenting the VA's Patient Aligned Care Team (PACT) medical home with PACT Intensive Management (PIM) teams for Veterans at highest risk for hospitalization. Researchers partnered with VHA leadership to design a mixed-methods prospective multi-site evaluation that met leadership's desire for a rigorous evaluation conducted as quality improvement rather than research. We conducted a randomized QI evaluation and assigned high-risk patients to participate in PIM and compared them with high-risk Veterans receiving usual care through PACT. The summative evaluation examines whether PIM: 1) decreases VHA emergency department and hospital use; 2) increases satisfaction with VHA care; 3) decreases provider burnout; and 4) generates positive returns on investment. The formative evaluation aims to support improved care for high-risk patients at demonstration sites and to inform future initiatives for high-risk patients. The evaluation was reviewed by representatives from the VHA Office of Research and Development and the Office of Research Oversight and met criteria for quality improvement. VHA aims to function as a learning organization by rapidly implementing and rigorously testing QI innovations prior to final program or policy development. We observed challenges and opportunities in designing an evaluation consistent with QI standards and operations priorities, while also maintaining scientific rigor. This trial was retrospectively registered at ClinicalTrials.gov on April 3, 2017: NCT03100526. Protocol v1, FY14-17. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. Time-dependent change of blood flow in the prostate treated with high-intensity focused ultrasound.

    PubMed

    Shoji, Sunao; Tonooka, Akiko; Hashimoto, Akio; Nakamoto, Masahiko; Tomonaga, Tetsuro; Nakano, Mayura; Sato, Haruhiro; Terachi, Toshiro; Koike, Junki; Uchida, Toyoaki

    2014-09-01

    Avascular areas on contrast-enhanced magnetic resonance imaging have been considered to be areas of localized prostate cancer successfully treated by high-intensity focused ultrasound. However, the optimal timing of magnetic resonance imaging has not been discussed. The thermal effect of high-intensity focused ultrasound is degraded by regional prostatic blood flow. Conversely, the mechanical effect of high-intensity focused ultrasound (cavitation) is not affected by blood flow, and can induce vessel damage. In this series, the longitudinal change of blood flow on contrast-enhanced magnetic resonance imaging was observed from postoperative day 1 to postoperative day 14 in 10 patients treated with high-intensity focused ultrasound. The median rates of increase in the non-enhanced volume of the whole gland, transition zone and peripheral zone from postoperative day 1 to postoperative day 14 were 36%, 39%, and 34%, respectively. In another pathological analysis of the prostate tissue of 17 patients immediately after high-intensity focused ultrasound without neoadjuvant hormonal therapy, we observed diffuse coagulative degeneration and partial non-coagulative prostate tissue around arteries with vascular endothelial cell detachment. These observations on contrast-enhanced magnetic resonance imaging support a time-dependent change of the blood flow in the prostate treated with high-intensity focused ultrasound. Additionally, our pathological findings support the longitudinal changes of these magnetic resonance imaging findings. Further large-scale studies will investigate the most appropriate timing of contrast-enhanced magnetic resonance imaging for evaluation of the effectiveness of high-intensity focused ultrasound for localized prostate cancer. © 2014 The Japanese Urological Association.

  6. Nanostructure array plasmas generated by femtosecond pulses at highly relativistic intensities

    NASA Astrophysics Data System (ADS)

    Hollinger, R. C.; Wong, Y.; Wong, S.; Rockwood, A.; Glasby, J.; Shlyaptsev, V.; Rocca, J. J.; Capeluto, M. G.; Kaymak, V.; Pukhov, A.

    2017-10-01

    The irradiation of high aspect ratio ordered nanostructure arrays with ultra-high contrast femtosecond laser pulses of relativistic intensity provides a unique combination of nearly complete optical absorption and drastically enhanced light penetration into near-solid density targets. This allows the material to be volumetrically heated deep into the ultra-high energy density regime. In previous experiments we have shown that irradiation of Ni and Au nanostructures with femtosecond pulses focused to an intensity of 5x1018 Wcm-2 generate multi-KeV near solid density plasmas in which atoms are ionized to the Ni+26 and Au+52 charge states. Here we present the first results of the irradiation of nanostructure arrays with highly relativistic pulses of intensities up to 5x1021Wcm-2. Silver and Rhodium nanowire arrays were irradiated with frequency-doubled pulses of 30 fs duration from a petawatt-class Ti:Sa laser. Time integrated x-ray spectra show the presence of He-like and Li-like emission. Results of experiments conducted with a variety of different nanowires diameters with a range of interwire spacings will be presented and compared to the result of 3D particle-in-cell-simulations. This work was supported by the Fusion Energy Program, Office of Science of the U.S Department of Energy.

  7. High-intensity interval training: Modulating interval duration in overweight/obese men.

    PubMed

    Smith-Ryan, Abbie E; Melvin, Malia N; Wingfield, Hailee L

    2015-05-01

    High-intensity interval training (HIIT) is a time-efficient strategy shown to induce various cardiovascular and metabolic adaptations. Little is known about the optimal tolerable combination of intensity and volume necessary for adaptations, especially in clinical populations. In a randomized controlled pilot design, we evaluated the effects of two types of interval training protocols, varying in intensity and interval duration, on clinical outcomes in overweight/obese men. Twenty-five men [body mass index (BMI) > 25 kg · m(2)] completed baseline body composition measures: fat mass (FM), lean mass (LM) and percent body fat (%BF) and fasting blood glucose, lipids and insulin (IN). A graded exercise cycling test was completed for peak oxygen consumption (VO2peak) and power output (PO). Participants were randomly assigned to high-intensity short interval (1MIN-HIIT), high-intensity interval (2MIN-HIIT) or control groups. 1MIN-HIIT and 2MIN-HIIT completed 3 weeks of cycling interval training, 3 days/week, consisting of either 10 × 1 min bouts at 90% PO with 1 min rests (1MIN-HIIT) or 5 × 2 min bouts with 1 min rests at undulating intensities (80%-100%) (2MIN-HIIT). There were no significant training effects on FM (Δ1.06 ± 1.25 kg) or %BF (Δ1.13% ± 1.88%), compared to CON. Increases in LM were not significant but increased by 1.7 kg and 2.1 kg for 1MIN and 2MIN-HIIT groups, respectively. Increases in VO2peak were also not significant for 1MIN (3.4 ml·kg(-1) · min(-1)) or 2MIN groups (2.7 ml · kg(-1) · min(-1)). IN sensitivity (HOMA-IR) improved for both training groups (Δ-2.78 ± 3.48 units; p < 0.05) compared to CON. HIIT may be an effective short-term strategy to improve cardiorespiratory fitness and IN sensitivity in overweight males.

  8. High-intensity interval training: Modulating interval duration in overweight/obese men

    PubMed Central

    Smith-Ryan, Abbie E.; Melvin, Malia N.; Wingfield, Hailee L.

    2015-01-01

    Introduction High-intensity interval training (HIIT) is a time-efficient strategy shown to induce various cardiovascular and metabolic adaptations. Little is known about the optimal tolerable combination of intensity and volume necessary for adaptations, especially in clinical populations. Objectives In a randomized controlled pilot design, we evaluated the effects of two types of interval training protocols, varying in intensity and interval duration, on clinical outcomes in overweight/obese men. Methods Twenty-five men [body mass index (BMI) > 25 kg·m2] completed baseline body composition measures: fat mass (FM), lean mass (LM) and percent body fat (%BF) and fasting blood glucose, lipids and insulin (IN). A graded exercise cycling test was completed for peak oxygen consumption (VO2peak) and power output (PO). Participants were randomly assigned to high-intensity short interval (1MIN-HIIT), high-intensity interval (2MIN-HIIT) or control groups. 1MIN-HIIT and 2MIN-HIIT completed 3 weeks of cycling interval training, 3 days/week, consisting of either 10 × 1 min bouts at 90% PO with 1 min rests (1MIN-HIIT) or 5 × 2 min bouts with 1 min rests at undulating intensities (80%–100%) (2MIN-HIIT). Results There were no significant training effects on FM (Δ1.06 ± 1.25 kg) or %BF (Δ1.13% ± 1.88%), compared to CON. Increases in LM were not significant but increased by 1.7 kg and 2.1 kg for 1MIN and 2MIN-HIIT groups, respectively. Increases in VO2peak were also not significant for 1MIN (3.4 ml·kg−1·min−1) or 2MIN groups (2.7 ml·kg−1·min−1). IN sensitivity (HOMA-IR) improved for both training groups (Δ −2.78 ± 3.48 units; p < 0.05) compared to CON. Conclusion HIIT may be an effective short-term strategy to improve cardiorespiratory fitness and IN sensitivity in overweight males. PMID:25913937

  9. Development of a cryogenic hydrogen microjet for high-intensity, high-repetition rate experiments

    DOE PAGES

    Kim, J. B.; Göde, S.; Glenzer, S. H.

    2016-08-19

    The advent of high-intensity, high-repetition-rate lasers has led to the need for replenishing targets of interest for high energy density sciences. We describe the design and characterization of a cryogenic microjet source, which can deliver a continuous stream of liquid hydrogen with a diameter of a few microns. The jet has been imaged at 1 μm resolution by shadowgraphy with a short pulse laser. In conclusion, the pointing stability has been measured at well below a mrad, for a stable free-standing filament of solid-density hydrogen.

  10. Private Tutoring Intensity in Schools: A Comparison between High and Low Socio-Economic Schools

    ERIC Educational Resources Information Center

    Addi-Raccah, Audrey; Dana, Oshra

    2015-01-01

    Private tutoring (PT) is becoming a worldwide phenomenon. In Israel too, about a third of elementary school students participate in PT. Based on sociological and school quality considerations, we examined school characteristics that are associated with PT intensity at school. The data encompassed a random state wide sample of 389 Israeli…

  11. Do alcohol use reasons and contexts differentiate adolescent high-intensity drinking? Data from U.S. high school seniors, 2005-2016.

    PubMed

    Terry-McElrath, Yvonne M; Stern, Stephanie A; Patrick, Megan E

    2017-11-01

    The purpose of this study was to examine associations between (a) self-reported reasons for and contexts of alcohol use and (b) high-intensity drinking (i.e., having 10+ drinks in a row in the past 2 weeks) among national samples of U.S. 12th grade students. Data were obtained from 16,902 students who reported any past 12-month alcohol use from nationally representative annual 12th grade student samples from 2005-2016. When asked about drinking behavior during the past 2 weeks, 72% reported consuming less than 5 drinks at most during 1 drinking occasion; 14% reported 5-9 drinks, 7% reported 10-14 drinks, and 7% reported 15+ drinks. Adolescent drinkers in all categories (<5, 5-9, 10-14, and 15+ drinks) endorsed "to have a good time" as the most prevalent reason for alcohol use, and "at a party" as the most prevalent context of alcohol use. However, high-intensity drinking was particularly likely among adolescents drinking for coping, compulsive use, and drug effect reasons, as well as those who enjoyed the taste. Having 15+ drinks (vs. 10-14 drinks) was particularly associated with compulsive use and enjoying the taste. The relative risk of any high-intensity drinking, and of higher levels of high-intensity drinking involvement, increased with the total number of reasons and contexts endorsed. Alcohol appears to serve a larger number of functions for high-intensity drinking adolescents than non-high-intensity drinking youth. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  12. High-intensity polarized H- ion source for the RHIC SPIN physics

    NASA Astrophysics Data System (ADS)

    Zelenski, A.; Atoian, G.; Raparia, D.; Ritter, J.; Kolmogorov, A.; Davydenko, V.

    2017-08-01

    A novel polarization technique had been successfully implemented for the RHIC polarized H- ion source upgrade to higher intensity and polarization. In this technique a proton beam inside the high magnetic field solenoid is produced by ionization of the atomic hydrogen beam (from external source) in the He-gas ionizer cell. Further proton polarization is produced in the process of polarized electron capture from the optically-pumped Rb vapour. The use of high-brightness primary beam and large cross-sections of charge-exchange cross-sections resulted in production of high intensity H- ion beam of 85% polarization. High beam brightness and polarization resulted in 75% polarization at 23 GeV out of AGS and 60-65% beam polarization at 100-250 GeV colliding beams in RHIC. The status of un-polarized magnetron type (Cs-vapour loaded) BNL source is also discussed.

  13. Study in Parkinson Disease of Exercise (SPARX): Translating high-intensity exercise from animals to humans

    PubMed Central

    Moore, Charity G.; Schenkman, Margaret; Kohrt, Wendy M.; Delitto, Anthony; Hall, Deborah A.; Corcos, Daniel

    2013-01-01

    A burgeoning literature suggests that exercise has a therapeutic benefit in persons with Parkinson disease (PD) and in animal models of PD, especially when animals exercise at high intensity. If exercise is to be prescribed as “first-line” or “add-on” therapy in patients with PD, we must demonstrate its efficacy and dose-response effects through testing phases similar to those used in the testing of pharmacologic agents. The SPARX Trial is a multicenter, randomized, controlled, single-blinded, Phase II study that we designed to test the feasibility of using high-intensity exercise to modify symptoms of PD and to simultaneously test the nonfutility of achieving a prespecified change in patients’ motor scores on the Unified Parkinson Disease Rating Scale (UPDRS). The trial began in May 2102 and is in the process of screening, enrolling, and randomly assigning 126 patients with early-stage PD to 1 of 3 groups: usual care (wait-listed controls), moderate-intensity exercise (4 days/week at 60%–65% maximal heart rate [HRmax]), or high-intensity exercise (4 days/week at 80%–85% HRmax). At 6-month follow-up, the trial is randomly reassigning usual care participants to a moderate-intensity or high-intensity exercise group for the remaining 6 months. The goals of the Phase II trial are to determine if participants can exercise at moderate and high intensities; to determine if either exercise yields benefits consistent with meaningful clinical change (nonfutility); and to document safety and attrition. The advantage of using a non-futility approach allows us to efficiently determine if moderate- or high-intensity exercise warrants further large-scale investigation in PD. PMID:23770108

  14. Effect of Zn and Te beam intensity upon the film quality of ZnTe layers on severely lattice mismatched sapphire substrates by molecular beam epitaxy

    NASA Astrophysics Data System (ADS)

    Nakasu, Taizo; Sun, W.; Kobayashi, M.; Asahi, T.

    2017-06-01

    Zinc telluride layers were grown on highly-lattice-mismatched sapphire substrates by molecular beam epitaxy, and their crystallographic properties were studied by means of X-ray diffraction pole figures. The crystal quality of the ZnTe thin film was further studied by scanning electron microscopy, X-ray rocking curves and low-temperature photoluminescence measurements. These methods show that high-crystallinity (111)-oriented single domain ZnTe layers with the flat surface and good optical properties are realized when the beam intensity ratio of Zn and Te beams is adjusted. The migration of Zn and Te was inhibited by excess surface material and cracks were appeared. In particular, excess Te inhibited the formation of a high-crystallinity ZnTe film. The optical properties of the ZnTe layer revealed that the exciton-related features were dominant, and therefore the film quality was reasonably high even though the lattice constants and the crystal structures were severely mismatched.

  15. [Effects of high-intensity interval training and nutritional education in patients with type 2 diabetes].

    PubMed

    Mangiamarchi, Pedro; Caniuqueo, Alexis; Ramírez-Campillo, Rodrigo; Cárdenas, Patricio; Morales, Sylvana; Cano-Montoya, Johnattan; Bresciani, Guilherme; Álvarez, Cristian

    2017-07-01

    High-intensity interval training (HIIT) improves cardiometabolic markers, but its effects on the quality of life of patients with type 2 diabetes (T2D) is not well known. To determine the effects of a 12-week HIIT exercise program on cardiometabolic and quality of life variables of T2D patients. Nine T2D women were assigned to a HIIT + nutritional education (GE) and 10, to a nutritional education alone group (GC). At baseline and after each intervention, anthropometric and body composition parameters using bio-impedance were assessed, and a blood sample was obtained to measure serum lipid levels, blood glucose and glycated hemoglobin. Quality of life was assessed using the SF-12 questionnaire adapted for the Chilean population. There were no significant changes on the lipid profile variables in the GE group, although HDL cholesterol was increased significantly (p < 0.05) in the GC group. Total fat mass was decreased in the GE group from 43.5 ± 1.5 to 41.9 ± 1.5%, p < 0.01. Fasting glucose and glycated hemoglobin decreased in the GE group. There was a significant correlation between the decrease in total fat mass and that of glycated hemoglobin. There were significant increases in quality of life parameters; physical function, physical role, pain, general health, vitality, emotional role, mental health, and social function in the GE but not in the GC group. A 12-week program of HIIT plus nutritional education improves cardiometabolic and quality of life parameters on type 2 diabetics.

  16. Clinical effect of reducing curing times with high-intensity LED lights

    PubMed Central

    Ward, Justin D.; Wolf, Bethany J.; Leite, Luis P.; Zhou, Jing

    2016-01-01

    Objective To evaluate the clinical performance of brackets cured with a high-intensity, light-emitting diode (LED) with a shorter curing time. Materials and Methods Thirty-four patients and a total of 680 brackets were examined using a randomized split-mouth design. The maxillary right and mandibular left quadrants were cured for 6 seconds with a high-intensity LED light (3200 mW/cm2) and the maxillary left and mandibular right quadrants were cured for 20 seconds with a standard-intensity LED light (1200 mW/cm2). Alternating patients had the quadrants inverted for the curing protocol. The number and date of each first-time bracket failure was recorded from 199 to 585 days posttreatment. Results The bracket failure rate was 1.18% for both curing methods. The proportion of bracket failure was not significantly different between curing methods (P = 1.000), genders (P = 1.000), jaws (P = .725), sides (P = .725), or quadrants (P = .547). Posterior teeth exhibited a greater proportion of failures (2.21%) relative to anterior teeth (0.49%), although the difference was not statistically significant (P = .065). Conclusions No difference was found in bond failure rates between the two curing methods. Both methods showed bond failure rates low enough to be considered clinically sufficient. The high-intensity LED light used with a shorter curing time may be considered an advantage due to the reduced chair time. PMID:25760887

  17. The effects of light emitting diode therapy following high intensity exercise.

    PubMed

    Denis, Romain; O'Brien, Christopher; Delahunt, Eamonn

    2013-05-01

    To determine the effects of light emitting diode therapy (LEDT) irradiation on blood lactate concentration ([La]) clearance, peak power output and fatigue index (FI) following high intensity fatiguing exercise. Single-blinded randomised cross-over placebo controlled trial. University College Dublin, Institute for Sport and Health, Human performance laboratory. Eighteen healthy male athletes were recruited from field-based sports (including soccer, hockey and rugby union) and participated in the present study. Dependent variables were the peak power output elicited during the Wingate Anaerobic Test (WAnT), FI and [La] before and after each exercise. WAnT performance was measured prior to high intensity fatiguing exercise (Yo-Yo IR2), prior to LEDT or placebo, and following LEDT or placebo. [La] was measured at baseline, immediately after the Yo-Yo IR2, and in the 3rd, 9th, and 15th min following LEDT or placebo condition. No significant group by treatment interactions were observed for any outcome measures (P > 0.05). We conclude that LEDT irradiation applied following high intensity exercise was not effective and has no immediate effect on [La] clearance, peak power and FI, and thus has no significant effect on muscle recovery in athletes at the intensity and irradiation parameters used in the present study. Further research using different parameters is required to determine how LEDT may contribute to post-exercise recovery. Copyright © 2012 Elsevier Ltd. All rights reserved.

  18. Associations of Low- and High-Intensity Light Activity with Cardiometabolic Biomarkers.

    PubMed

    Howard, Bethany; Winkler, Elisabeth A H; Sethi, Parneet; Carson, Valerie; Ridgers, Nicola D; Salmon, J O; Healy, Genevieve N; Owen, Neville; Dunstan, David W

    2015-10-01

    Light-intensity physical activity (LIPA) accounts for much of adults' waking hours (≈40%) and substantially contributes to overall daily energy expenditure. Encompassing activity behaviors of low intensity (standing with little movement) to those of higher intensity (slow walking), LIPA is ubiquitous, yet little is known about how associations with health may vary depending on its intensity. We examined the associations of objectively assessed LIPA (categorized as either low LIPA [LLPA] or high LIPA [HLPA]) and moderate- to vigorous-intensity activity with cardiometabolic risk biomarkers. Cardiometabolic biomarkers were measured in 4614 US adults (47 ± 17 yr) who participated in the 2003-2004 and 2005-2006 National Health and Nutrition Examination Survey cycles. Multiple linear regression analyses examined the associations of three accelerometer-derived physical activity (SD increment per day) intensity categories (LLPA, 100-761 counts per minute; HLPA, 762-1951 counts per minute; moderate-intensity physical activity [MPA], 1952-5724 counts per minute; vigorous-intensity physical activity [VPA], ≥5725 counts per minute) with cardiometabolic biomarkers, adjusting for potential sociodemographic, behavioral, and medical confounders. All intensities of physical activity were beneficially associated with waist circumference, C-reactive protein, triglycerides, fasting insulin, β-cell function, and insulin sensitivity (P < 0.05); only some activity intensities showed significant associations with systolic blood pressure (LLPA), body mass index, HDL cholesterol, fasting glucose, and 2-h plasma glucose (HLPA, MPA, and VPA). Generally, effect size increased with intensity of physical activity. Overall, further adjustment for waist circumference attenuated associations with MPA and VPA to a greater extent than associations with LLPA and HLPA. The cross-sectional findings provide novel evidence for the potential benefits of increasing both LLPA and HLPA. They further

  19. First archaeointensity catalogue and intensity secular variation curve for Iberia spanning the last 3000 years

    NASA Astrophysics Data System (ADS)

    Molina-Cardín, Alberto; Campuzano, Saioa A.; Rivero, Mercedes; Osete, María Luisa; Gómez-Paccard, Miriam; Pérez-Fuentes, José Carlos; Pavón-Carrasco, F. Javier; Chauvin, Annick; Palencia-Ortas, Alicia

    2017-04-01

    In this work we present the first archaeomagnetic intensity database for the Iberian Peninsula covering the last 3 millennia. In addition to previously published archaeointensities (about 100 data), we present twenty new high-quality archaeointensities. The new data have been obtained following the Thellier and Thellier method including pTRM-checks and have been corrected for the effect of the anisotropy of thermoremanent magnetization upon archaeointensity estimates. Importantly, about 50% of the new data obtained correspond to the first millennium BC, a period for which there was not possible to develop an intensity palaeosecular variation curve before due to the lack of high-quality archaeointensity data. The different qualities of the data included in the Iberian dataset have been evaluated following different palaeomagnetic criteria, such as the number of specimens analysed, the laboratory protocol applied and the kind of material analysed. Finally, we present the first intensity palaeosecular variation curve for the Iberian Peninsula centred at Madrid for the last 3000 years. In order to obtain the most reliable secular variation curve, it has been generated using only selected high-quality data from the catalogue.

  20. Sterilizing effects of high-intensity airborne sonic and ultrasonic waves.

    PubMed

    Pisano, M A; Boucher, M G; Alcamo, I E

    1966-09-01

    The lethal effects of high-intensity airborne sonic (9.9 kc/sec) and ultrasonic waves (30.4 kc/sec) on spores of Bacillus subtilis var. niger ATCC 9372 were determined. The spores, which were deposited on filter-paper strips, were exposed to sound waves for periods varying from 1 to 8 hr, at a temperature of 40 C and a relative humidity of 40%. Significant reductions in the viable counts of spores exposed to airborne sonic or ultrasonic irradiations were obtained. The antibacterial activity of airborne sound waves varied with the sound intensity level, the period of irradiation, and the distance of the sample from the sound source. At similar intensity levels, the amplitude of motion of the sound waves appeared to be a factor in acoustic sterilization.

  1. An Automated Treatment Plan Quality Control Tool for Intensity-Modulated Radiation Therapy Using a Voxel-Weighting Factor-Based Re-Optimization Algorithm.

    PubMed

    Song, Ting; Li, Nan; Zarepisheh, Masoud; Li, Yongbao; Gautier, Quentin; Zhou, Linghong; Mell, Loren; Jiang, Steve; Cerviño, Laura

    2016-01-01

    Intensity-modulated radiation therapy (IMRT) currently plays an important role in radiotherapy, but its treatment plan quality can vary significantly among institutions and planners. Treatment plan quality control (QC) is a necessary component for individual clinics to ensure that patients receive treatments with high therapeutic gain ratios. The voxel-weighting factor-based plan re-optimization mechanism has been proved able to explore a larger Pareto surface (solution domain) and therefore increase the possibility of finding an optimal treatment plan. In this study, we incorporated additional modules into an in-house developed voxel weighting factor-based re-optimization algorithm, which was enhanced as a highly automated and accurate IMRT plan QC tool (TPS-QC tool). After importing an under-assessment plan, the TPS-QC tool was able to generate a QC report within 2 minutes. This QC report contains the plan quality determination as well as information supporting the determination. Finally, the IMRT plan quality can be controlled by approving quality-passed plans and replacing quality-failed plans using the TPS-QC tool. The feasibility and accuracy of the proposed TPS-QC tool were evaluated using 25 clinically approved cervical cancer patient IMRT plans and 5 manually created poor-quality IMRT plans. The results showed high consistency between the QC report quality determinations and the actual plan quality. In the 25 clinically approved cases that the TPS-QC tool identified as passed, a greater difference could be observed for dosimetric endpoints for organs at risk (OAR) than for planning target volume (PTV), implying that better dose sparing could be achieved in OAR than in PTV. In addition, the dose-volume histogram (DVH) curves of the TPS-QC tool re-optimized plans satisfied the dosimetric criteria more frequently than did the under-assessment plans. In addition, the criteria for unsatisfied dosimetric endpoints in the 5 poor-quality plans could typically be

  2. An Automated Treatment Plan Quality Control Tool for Intensity-Modulated Radiation Therapy Using a Voxel-Weighting Factor-Based Re-Optimization Algorithm

    PubMed Central

    Song, Ting; Li, Nan; Zarepisheh, Masoud; Li, Yongbao; Gautier, Quentin; Zhou, Linghong; Mell, Loren; Jiang, Steve; Cerviño, Laura

    2016-01-01

    Intensity-modulated radiation therapy (IMRT) currently plays an important role in radiotherapy, but its treatment plan quality can vary significantly among institutions and planners. Treatment plan quality control (QC) is a necessary component for individual clinics to ensure that patients receive treatments with high therapeutic gain ratios. The voxel-weighting factor-based plan re-optimization mechanism has been proved able to explore a larger Pareto surface (solution domain) and therefore increase the possibility of finding an optimal treatment plan. In this study, we incorporated additional modules into an in-house developed voxel weighting factor-based re-optimization algorithm, which was enhanced as a highly automated and accurate IMRT plan QC tool (TPS-QC tool). After importing an under-assessment plan, the TPS-QC tool was able to generate a QC report within 2 minutes. This QC report contains the plan quality determination as well as information supporting the determination. Finally, the IMRT plan quality can be controlled by approving quality-passed plans and replacing quality-failed plans using the TPS-QC tool. The feasibility and accuracy of the proposed TPS-QC tool were evaluated using 25 clinically approved cervical cancer patient IMRT plans and 5 manually created poor-quality IMRT plans. The results showed high consistency between the QC report quality determinations and the actual plan quality. In the 25 clinically approved cases that the TPS-QC tool identified as passed, a greater difference could be observed for dosimetric endpoints for organs at risk (OAR) than for planning target volume (PTV), implying that better dose sparing could be achieved in OAR than in PTV. In addition, the dose-volume histogram (DVH) curves of the TPS-QC tool re-optimized plans satisfied the dosimetric criteria more frequently than did the under-assessment plans. In addition, the criteria for unsatisfied dosimetric endpoints in the 5 poor-quality plans could typically be

  3. Can Intensity-Modulated Radiotherapy Preserve Oral Health-Related Quality of Life of Nasopharyngeal Carcinoma Patients?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pow, Edmond H.N., E-mail: ehnpow@hku.hk; Kwong, Dora L.W.; Sham, Jonathan S.T.

    Purpose: To investigate the changes in salivary function and oral health-related quality of life for patients with nasopharyngeal carcinoma treated by intensity-modulated radiotherapy (IMRT). Methods and Materials: A total of 57 patients with early-stage nasopharyngeal carcinoma received IMRT. The parotid and whole saliva flow was measured, and the Medical Outcomes Study 36-item short form, European Organization for Research and Treatment of Cancer Quality of Life questionnaire-C30, European Organization for Research and Treatment of Cancer Quality of Life questionnaire 35-item head-and-neck module, and Oral Health Impact Profile questionnaires were completed at baseline and 2, 6, 12, 18, and 24 months aftermore » IMRT. Results: Parotid saliva flow recovered fully after 1 year and maintained. Whole saliva flow recovered partially to 40% of baseline. A general trend of deterioration in most quality of life scales was observed after IMRT, followed by gradual recovery. Persistent oral-related symptoms were found 2 years after treatment. Conclusion: IMRT for early-stage nasopharyngeal carcinoma could only partially preserve the whole salivary function and oral health-related quality of life.« less

  4. Femtosecond dynamics of energetic electrons in high intensity laser-matter interactions

    NASA Astrophysics Data System (ADS)

    Pompili, R.; Anania, M. P.; Bisesto, F.; Botton, M.; Castellano, M.; Chiadroni, E.; Cianchi, A.; Curcio, A.; Ferrario, M.; Galletti, M.; Henis, Z.; Petrarca, M.; Schleifer, E.; Zigler, A.

    2016-10-01

    Highly energetic electrons are generated at the early phases of the interaction of short-pulse high-intensity lasers with solid targets. These escaping particles are identified as the essential core of picosecond-scale phenomena such as laser-based acceleration, surface manipulation, generation of intense magnetic fields and electromagnetic pulses. Increasing the number of the escaping electrons facilitate the late time processes in all cases. Up to now only indirect evidences of these important forerunners have been recorded, thus no detailed study of the governing mechanisms was possible. Here we report, for the first time, direct time-dependent measurements of energetic electrons ejected from solid targets by the interaction with a short-pulse high-intensity laser. We measured electron bunches up to 7 nanocoulombs charge, picosecond duration and 12 megaelectronvolts energy. Our ’snapshots’ capture their evolution with an unprecedented temporal resolution, demonstrat- ing a significant boost in charge and energy of escaping electrons when increasing the geometrical target curvature. These results pave the way toward significant improvement in laser acceleration of ions using shaped targets allowing the future development of small scale laser-ion accelerators.

  5. Controlled generation of high-intensity optical rogue waves by induced modulation instability

    PubMed Central

    Zhao, Saili; Yang, Hua; Chen, Nengsong; Zhao, Chujun

    2017-01-01

    Optical rogue waves are featured as the generation of high amplitude events at low probability in optical systems. Moreover, the formation of optical rogue waves is unpredictable and transient in photonic crystal fibers. In this paper, we put forward a method to generate high-intensity optical rogue waves in a more controlled way based on induced modulation instability, which can suppress the noise effect and hence play a leading role in the process of pulse evolution. Our numerical simulations indicate that the generation of rogue wave can be controlled when seeding at the optimal modulation frequency and the intensity of rogue wave can be enhanced with appropriate modulation depth. Further, high-intensity rogue wave can also be ejected in the fiber with a shorter propagation length by regulating the modulation depth. These results all provide a better understanding of optical rogue wave, which can contribute to the generation of tunable long-wavelength spectral components and selective excitation of mid-infrared supercontinuum. PMID:28051149

  6. Controlled generation of high-intensity optical rogue waves by induced modulation instability.

    PubMed

    Zhao, Saili; Yang, Hua; Chen, Nengsong; Zhao, Chujun

    2017-01-04

    Optical rogue waves are featured as the generation of high amplitude events at low probability in optical systems. Moreover, the formation of optical rogue waves is unpredictable and transient in photonic crystal fibers. In this paper, we put forward a method to generate high-intensity optical rogue waves in a more controlled way based on induced modulation instability, which can suppress the noise effect and hence play a leading role in the process of pulse evolution. Our numerical simulations indicate that the generation of rogue wave can be controlled when seeding at the optimal modulation frequency and the intensity of rogue wave can be enhanced with appropriate modulation depth. Further, high-intensity rogue wave can also be ejected in the fiber with a shorter propagation length by regulating the modulation depth. These results all provide a better understanding of optical rogue wave, which can contribute to the generation of tunable long-wavelength spectral components and selective excitation of mid-infrared supercontinuum.

  7. Radiation control in the intensive care unit for high intensity iridium-192 brain implants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sewchand, W.; Drzymala, R.E.; Amin, P.P.

    A bedside lead cubicle was designed to minimize the radiation exposure of intensive care unit staff during routine interstitial brain irradiation by removable, high intensity iridium-192. The cubicle shields the patient without restricting intensive care routines. The design specifications were confirmed by exposure measurements around the shield with an implanted anthropomorphic phantom simulating the patient situation. The cubicle reduces the exposure rate around an implant patient by as much as 90%, with the exposure level not exceeding 0.1 mR/hour/mg of radium-equivalent /sup 192/Ir. Evaluation of data accumulated for the past 3 years has shown that the exposure levels of individualmore » attending nurses are 0.12 to 0.36 mR/mg of radium-equivalent /sup 192/Ir per 12-hour shift. The corresponding range for entire nursing teams varies between 0.18 and 0.26. A radiation control index (exposure per mg of radium-equivalent /sup 192/Ir per nurse-hour) is thus defined for individual nurses and nursing teams; this index is a significant guide to the planning of nurse rotations for brain implant patients with various /sup 192/Ir loads. The bedside shield reduces exposure from /sup 192/Ir implants by a factor of about 20, as expected, and the exposure from the lower energy radioisotope iodine-125 is barely detectable.« less

  8. Different Polar Metabolites and Protein Profiles between High- and Low-Quality Japanese Ginjo Sake

    PubMed Central

    Takahashi, Kei; Kohno, Hiromi

    2016-01-01

    Japanese ginjo sake is a premium refined sake characterized by a pleasant fruity apple-like flavor and a sophisticated taste. Because of technical difficulties inherent in brewing ginjo sake, off-flavors sometimes occur. However, the metabolites responsible for off-flavors as well as those present or absent in higher quality ginjo sake remain uncertain. Here, the relationship between 202 polar chemical compounds in sake identified using capillary electrophoresis coupled with time-of-flight mass spectrometry and its organoleptic properties, such as quality and off-flavor, was examined. First, we found that some off-flavored sakes contained higher total amounts of metabolites than other sake samples. The results also identified that levels of 2-oxoglutaric acid and fumaric acid, metabolites in the tricarboxylic acid cycle, were highly but oppositely correlated with ginjo sake quality. Similarly, pyridoxine and pyridoxamine, co-enzymes for amino transferase, were also highly but oppositely correlated with ginjo sake quality. Additionally, pyruvic acid levels were associated with good quality as well. Compounds involved in the methionine salvage cycle, oxidative glutathione derivatives, and amino acid catabolites were correlated with low quality. Among off-flavors, an inharmonious bitter taste appeared attributable to polyamines. Furthermore, protein analysis displayed that a diversity of protein components and yeast protein (triosephosphate isomerase, TPI) leakage was linked to the overall metabolite intensity in ginjo sake. This research provides insight into the relationship between sake components and organoleptic properties. PMID:26939054

  9. Continence and quality-of-life outcomes 6 months following an intensive pelvic-floor muscle exercise program for female stress urinary incontinence: a randomized trial comparing low- and high-frequency maintenance exercise.

    PubMed

    Borello-France, Diane F; Downey, Patricia A; Zyczynski, Halina M; Rause, Christine R

    2008-12-01

    Few studies have examined the effectiveness of pelvic-floor muscle (PFM) exercises to reduce female stress urinary incontinence (SUI) over the long term. This study: (1) evaluated continence and quality-of-life outcomes of women 6 months following formalized therapy and (2) determined whether low- and high-frequency maintenance exercise programs were equivalent in sustaining outcomes. Thirty-six women with SUI who completed an intensive PFM exercise intervention trial were randomly assigned to perform a maintenance exercise program either 1 or 4 times per week. Urine leaks per week, volume of urine loss, quality of life (Incontinence Impact Questionnaire [IIQ] score), PFM strength (Brink score), and prevalence of urodynamic stress incontinence (USI) were measured at a 6-month follow-up for comparison with postintervention status. Parametric and nonparametric statistics were used to determine differences in outcome status over time and between exercise frequency groups. Twenty-eight women provided follow-up data. Postintervention status was sustained at 6 months for all outcomes (mean [SD] urine leaks per week=1.2+/-2.1 versus 1.4+/-3.1; mean [SD] urine loss=0.2+/-0.5 g versus 0.2+/-0.8 g; mean [SD] IIQ score=17+/-20 versus 22+/-30; mean [SD] Brink score=11+/-1 versus 11+/-1; and prevalence of USI=48% versus 35%). Women assigned to perform exercises once or 4 times per week similarly sustained their postintervention status. Benefits of an initial intensive intervention program for SUI were sustained over 6 months. However, only 15 of the 28 women provided documentation of their exercise adherence, limiting conclusions regarding the need for continued PFM exercise during follow-up intervals of

  10. Plating Processes Utilizing High Intensity Acoustic Beams

    NASA Technical Reports Server (NTRS)

    Oeftering, Richard C. (Inventor); Denofrio, Charles (Inventor)

    2002-01-01

    A system and a method for selective plating processes are disclosed which use directed beams of high intensity acoustic waves to create non-linear effects that alter and improve the plating process. The directed beams are focused on the surface of an object, which in one embodiment is immersed in a plating solution, and in another embodiment is suspended above a plating solution. The plating processes provide precise control of the thickness of the layers of the plating, while at the same time, in at least some incidents, eliminates the need for masking.

  11. Effect of Power Ultrasound on Food Quality

    NASA Astrophysics Data System (ADS)

    Lee, Hyoungill; Feng, Hao

    Recent food processing technology innovations have been centered around producing foods with fresh-like attributes through minimal processing or nonthermal processing technologies. Instead of using thermal energy to secure food safety that is often accompanied by quality degradation in processed foods, the newly developed processing modalities utilize other types of physical energy such as high pressure, pulsed electric field or magnetic field, ultraviolet light, or acoustic energy to process foods. An improvement in food quality by the new processing methods has been widely reported. In comparison with its low-energy (high-frequency) counterpart which finds applications in food quality inspection, the use of high-intensity ultrasound, also called power ultrasound, in food processing is a relatively new endeavor. To understand the effect of high-intensity ultrasound treatment on food quality, it is important to understand the interactions between acoustic energy and food ingredients, which is covered in Chapter 10. In this chapter, the focus will be on changes in overall food quality attributes that are caused by ultrasound, such as texture, color, flavor, and nutrients.

  12. [The German DRG system 2003-2010 from the perspective of intensive care medicine].

    PubMed

    Franz, Dominik; Bunzemeier, Holger; Roeder, Norbert; Reinecke, Holger

    2010-01-01

    Intensive care medicine is extremely heterogeneous, expensive and can only be partially planned and controlled. A correct and fair representation of intensive care medicine in the G-DRG system is an essential requirement for the use as a pricing system. From the perspective of intensive care medicine, pertinent changes of the DRG structure and differentiation of relevant parameters have been established within the G-DRG systems 2003-2010. Analysis of relevant diagnoses, medical procedures, co-payment structures and G-DRGs in the versions 2003-2010 based on the publications of the German DRG Institute (InEK) and the German Institute of Medical Documentation and Information (DIMDI). Since the first G-DRG system version 2003, numerous measures improved quality of case allocation of intensive care medicine. Highly relevant to the system version 2010 are duration of mechanical ventilation, the intensive care treatment complex and complicating constellations. The number of G-DRGs relevant to intensive medical care increased from n = 3 (2003) to n = 58 (2010). For standard cases, quality of case allocation and G-DRG reimbursement are adequate in 2010. The G-DRG system gained complexity again. High demands are made on correct and complete coding of complex cases. Nevertheless, further adjustments of the G-DRG system especially for cases with extremely high costs are necessary. Where the G-DRG system is unable to cover extremely high-cost cases, reimbursement solutions beyond the G-DRG structure should be taken into account.

  13. [Evacuation plan of an intensive care unit: a new quality indicator?].

    PubMed

    Sánchez-Palacios, M; Lorenzo Torrent, R; Santana-Cabrera, L; Martín García, J A; Campos, S G; Carrasco de Miguel, V

    2010-04-01

    The intensive care units must be prepared for a possible disaster, whether internal or external, in case it becomes necessary to evacuate the in-patients. They must have an Emergency and Self-protection Plan that includes the patient evacuation criteria and this must be known by all the personnel who work in the service. For that reason, the patients must be triaged, based on their attention priorities, according to their survival possibilities. Having an evacuation, known by all the personnel and updated by means of the performance of periodic drills, should be included as a quality indicator that must be met, since this would achieve better attention to the patient in case of a disaster situation requiring the evacuation of the ICU. Copyright 2009 Elsevier España, S.L. y SEMICYUC. All rights reserved.

  14. High Intensity Laser Power Beaming Architecture for Space and Terrestrial Missions

    NASA Technical Reports Server (NTRS)

    Nayfeh, Taysir; Fast, Brian; Raible, Daniel; Dinca, Dragos; Tollis, Nick; Jalics, Andrew

    2011-01-01

    High Intensity Laser Power Beaming (HILPB) has been developed as a technique to achieve Wireless Power Transmission (WPT) for both space and terrestrial applications. In this paper, the system architecture and hardware results for a terrestrial application of HILPB are presented. These results demonstrate continuous conversion of high intensity optical energy at near-IR wavelengths directly to electrical energy at output power levels as high as 6.24 W from the single cell 0.8 cm2 aperture receiver. These results are scalable, and may be realized by implementing receiver arraying and utilizing higher power source lasers. This type of system would enable long range optical refueling of electric platforms, such as MUAV s, airships, robotic exploration missions and provide power to spacecraft platforms which may utilize it to drive electric means of propulsion.

  15. Do relationships exist between the scope and intensity of quality improvement activities and hospital operation performance? A 10-year observation in Taiwan.

    PubMed

    Chung, Kuo-Piao; Yu, Tsung-Hsien

    2015-08-14

    The relationship between the scope and intensity of quality improvement (QI) activities and hospital performance remains unclear. This study investigated the relationship between performance, external environment, and the scope and intensity of QI activities in hospitals. The study used a longitudinal observation. Data regarding the scope and intensity of QI activities were collected using a questionnaire survey among the administrative deputy superintendents / directors of quality management center in 139 hospitals. Hospital performance indicators were abstracted from the 2000-2009 national hospitals profiles. We adopted year 2000 as the baseline, and divided the study period into three 3-year periods. The Generalized Estimating Equations (GEE) model was used for the statistical analysis. Seventy-two hospitals responded to the survey, giving a response rate of 52%. The results showed a significant increase in the scope and intensity of QI activities between 2000 and 2009. The results also showed that the scope and intensity of a hospital's QI activities were associated with the scope and intensity of its competitors' QI activities in the previous period and its own prior performance. The scope of QI activities in the previous period was not significantly related to the selected hospital performance measures. However, the intensity of QI activities in the previous period showed a significant and positive relationship with the number of inpatients and the turnover of beds. The study demonstrates that the intensity of QI activities is associated with the external environment and the hospital's own performance in the previous period. Furthermore, some performance measures are associated with the intensity of the QI activities in the previous period.

  16. Much potential but many unanswered questions for high-intensity intermittent exercise training for patients with heart failure.

    PubMed

    Pinkstaff, Sherry O

    2015-01-01

    There is a robust trove of scientific studies that support the positive physical and mental health benefits associated with aerobic exercise for healthy individuals. These recommendations suggest that more vigorous exercise can be performed on fewer days for the same benefit. High-intensity intermittent exercise (HIIE) training has begun to show promise. HIIE seems safe and improves physiology, quality of life, and functional capacity. This review defines HIIE, discusses its physiologic benefit for patients with heart failure, outlines the studies that have been conducted to date, and places it in the context of the current clinical environment of exercise training for these patients. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. 36 CFR 910.31 - High architectural quality.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 36 Parks, Forests, and Public Property 3 2014-07-01 2014-07-01 false High architectural quality... PENNSYLVANIA AVENUE DEVELOPMENT AREA Standards Uniformly Applicable to the Development Area § 910.31 High architectural quality. Development must maintain a uniformly high standard of architecture, representative of...

  18. 36 CFR 910.31 - High architectural quality.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 36 Parks, Forests, and Public Property 3 2012-07-01 2012-07-01 false High architectural quality... PENNSYLVANIA AVENUE DEVELOPMENT AREA Standards Uniformly Applicable to the Development Area § 910.31 High architectural quality. Development must maintain a uniformly high standard of architecture, representative of...

  19. The applicability of high intensity sheeting on overhead highway signs.

    DOT National Transportation Integrated Search

    1975-01-01

    This report summarizes (1) the findings of a research study on the applicability of using high intensity reflective sheeting on overhead signs, and (2) the implementation of recommendations evolving from these findings through elimination of the illu...

  20. Is Pain Intensity Really That Important to Assess in Chronic Pain Patients? A Study Based on the Swedish Quality Registry for Pain Rehabilitation (SQRP)

    PubMed Central

    Bromley Milton, Maria; Börsbo, Björn; Rovner, Graciela; Lundgren-Nilsson, Åsa; Stibrant-Sunnerhagen, Katharina; Gerdle, Björn

    2013-01-01

    Background Incorporating the patient's view on care and treatment has become increasingly important for health care. Patients describe the variety of consequences of their chronic pain conditions as significant pain intensity, depression, and anxiety. We hypothesised that intensities of common symptoms in chronic pain conditions carry important information that can be used to identify clinically relevant subgroups. This study has three aims: 1) to determine the importance of different symptoms with respect to participation and ill-health; 2) to identify subgroups based on data concerning important symptoms; and 3) to determine the secondary consequences for the identified subgroups with respect to participation and health factors. Methods and Subjects This study is based on a cohort of patients referred to a multidisciplinary pain centre at a university hospital (n = 4645, participation rate 88%) in Sweden. The patients answered a number of questionnaires concerning symptoms, participation, and health aspects as a part of the Swedish Quality Registry for Pain Rehabilitation (SQRP). Results Common symptoms (such as pain intensity, depression, and anxiety) in patients with chronic pain showed great variability across subjects and 60% of the cohort had normal values with respect to depressive and anxiety symptoms. Pain intensity more than psychological symptoms showed stronger relationships with participation and health. It was possible to identify subgroups based on pain intensity, depression, and anxiety. With respect to participation and health, high depressive symptomatology had greater negative consequences than high anxiety. Conclusions Common symptoms (such as pain intensity and depressive and anxiety symptoms) in chronic pain conditions carry important information that can be used to identify clinically relevant subgroups. PMID:23805183

  1. Improving Teaching Effectiveness: Implementation. The Intensive Partnerships for Effective Teaching through 2013-2014

    ERIC Educational Resources Information Center

    Stecher, Brian M.; Garet, Michael S.; Hamilton, Laura S.; Steiner, Elizabeth D.; Robyn, Abby; Poirier, Jeffrey; Holtzman, Deborah; Fulbeck, Eleanor S.; Chambers, Jay; de los Reyes, Iliana Brodziak

    2016-01-01

    To improve the U.S. education system through more-effective classroom teaching, in school year 2009-2010, the Bill and Melinda Gates Foundation announced four Intensive Partnership for Effective Teaching sites. The Intensive Partnerships Initiative is based on the premise that efforts to improve instruction can benefit from high-quality measures…

  2. [Update: studies in intensive care medicine. Results of the last 12 months].

    PubMed

    Knapp, J; Marx, G; Weismüller, K; Steinebach, S; Lichtenstern, C; Popp, E; Mayer, K; Brunkhorst, F M; Weigand, M A; Bernhard, M

    2011-11-01

    Intensive care medicine plays an important role in the medical care of patients as well as the economic success of hospitals. Knowledge and implementation of recent relevant scientific evidence are prerequisites for high quality care in intensive care medicine. The aim of this review is to present an overview of the most important publications in intensive care medicine published in 2010 and the first half of the year 2011 and to comment on their attributable clinical relevance for intensive care practitioners. In 2010 and up to June 2011 many studies with high patient numbers have been published. The main topics were the treatment of respiratory failure, sepsis and investigations to improve analgosedation.

  3. Low-intensity red and infrared laser effects at high fluences on Escherichia coli cultures

    PubMed Central

    Barboza, L.L.; Campos, V.M.A.; Magalhães, L.A.G.; Paoli, F.; Fonseca, A.S.

    2015-01-01

    Semiconductor laser devices are readily available and practical radiation sources providing wavelength tenability and high monochromaticity. Low-intensity red and near-infrared lasers are considered safe for use in clinical applications. However, adverse effects can occur via free radical generation, and the biological effects of these lasers from unusually high fluences or high doses have not yet been evaluated. Here, we evaluated the survival, filamentation induction and morphology of Escherichia coli cells deficient in repair of oxidative DNA lesions when exposed to low-intensity red and infrared lasers at unusually high fluences. Cultures of wild-type (AB1157), endonuclease III-deficient (JW1625-1), and endonuclease IV-deficient (JW2146-1) E. coli, in exponential and stationary growth phases, were exposed to red and infrared lasers (0, 250, 500, and 1000 J/cm2) to evaluate their survival rates, filamentation phenotype induction and cell morphologies. The results showed that low-intensity red and infrared lasers at high fluences are lethal, induce a filamentation phenotype, and alter the morphology of the E. coli cells. Low-intensity red and infrared lasers have potential to induce adverse effects on cells, whether used at unusually high fluences, or at high doses. Hence, there is a need to reinforce the importance of accurate dosimetry in therapeutic protocols. PMID:26445339

  4. Anthropometric, Sprint, and High-Intensity Running Profiles of English Academy Rugby Union Players by Position.

    PubMed

    Darrall-Jones, Joshua D; Jones, Ben; Till, Kevin

    2016-05-01

    The purpose of this study was to evaluate the anthropometric, sprint, and high-intensity running profiles of English academy rugby union players by playing positions, and to investigate the relationships between anthropometric, sprint, and high-intensity running characteristics. Data were collected from 67 academy players after the off-season period and consisted of anthropometric (height, body mass, sum of 8 skinfolds [∑SF]), 40-m linear sprint (5-, 10-, 20-, and 40-m splits), the Yo-Yo intermittent recovery test level 1 (Yo-Yo IRTL-1), and the 30-15 intermittent fitness test (30-15 IFT). Forwards displayed greater stature, body mass, and ∑SF; sprint times and sprint momentum, with lower high-intensity running ability and sprint velocities than backs. Comparisons between age categories demonstrated body mass and sprint momentum to have the largest differences at consecutive age categories for forwards and backs; whereas 20-40-m sprint velocity was discriminate for forwards between under 16s, 18s, and 21s. Relationships between anthropometric, sprint velocity, momentum, and high-intensity running ability demonstrated body mass to negatively impact on sprint velocity (10 m; r = -0.34 to -0.46) and positively affect sprint momentum (e.g., 5 m; r = 0.85-0.93), with large to very large negative relationships with the Yo-Yo IRTL-1 (r = -0.65 to -0.74) and 30-15 IFT (r = -0.59 to -0.79). These findings suggest that there are distinct anthropometric, sprint, and high-intensity running ability differences between and within positions in junior rugby union players. The development of sprint and high-intensity running ability may be impacted by continued increases in body mass as there seems to be a trade-off between momentum, velocity, and the ability to complete high-intensity running.

  5. Performances of BNL high-intensity synchrotrons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weng, W.T.

    1998-03-01

    The AGS proton synchrotron was completed in 1960 with initial intensity in the 10 to the 10th power proton per pulse (ppp) range. Over the years, through many upgrades and improvements, the AGS now reached an intensity record of 6.3 {times} 10{sup 13} ppp, the highest world intensity record for a proton synchrotron on a single pulse basis. At the same time, the Booster reached 2.2 {times} 10{sup 13} ppp surpassing the design goal of 1.5 {times} 10{sup 13} ppp due to the introduction of second harmonic cavity during injection. The intensity limitation caused by space charge tune spread andmore » its relationship to injection energy at 50 MeV, 200 MeV, and 1,500 MeV will be presented as well as many critical accelerator manipulations. BNL currently participates in the design of an accumulator ring for the SNS project at Oak Ridge. The status on the issues of halo formation, beam losses and collimation are also presented.« less

  6. Diet composition and the performance of high-intensity exercise.

    PubMed

    Maughan, R J; Greenhaff, P L; Leiper, J B; Ball, D; Lambert, C P; Gleeson, M

    1997-06-01

    The crucial role of muscle glycogen as a fuel during prolonged exercise is well established, and the effects of acute changes in dietary carbohydrate intake on muscle glycogen content and on endurance capacity are equally well known. More recently, it has been recognized that diet can also affect the performance of high-intensity exercise of short (2-7 min) duration. If the muscle glycogen content is lowered by prolonged (1-1.5 h) exhausting cycle exercise, and is subsequently kept low for 3-4 days by consumption of a diet deficient in carbohydrate (< 5% of total energy intake), there is a dramatic (approximately 10-30%) reduction in exercise capacity during cycling sustainable for about 5 min. The same effect is observed if exercise is preceded by 3-4 days on a carbohydrate-restricted diet or by a 24 h total fast without prior depletion of the muscle glycogen. Consumption of a diet high in carbohydrate (70% of total energy intake from carbohydrate) for 3-4 days before exercise improves exercise capacity during high-intensity exercise, although this effect is less consistent. The blood lactate concentration is always lower at the point of fatigue after a diet low in carbohydrate and higher after a diet high in carbohydrate than after a normal diet. Even when the duration of the exercise task is kept constant, the blood lactate concentration is higher after exercise on a diet high in carbohydrate than on a diet low in carbohydrate. Consumption of a low-carbohydrate isoenergetic diet is achieved by an increased intake of protein and fat. A high-protein diet, particularly when combined with a low carbohydrate intake, results in metabolic acidosis, which ensues within 24 h and persists for at least 4 days. This appears to be the result of an increase in the circulating concentrations of strong organic acids, particularly free fatty acids and 3-hydroxybutyrate, together with an increase in the total plasma protein concentration. This acidosis, rather than any decrease

  7. Effects of High-Intensity Intermittent Exercise Training on Appetite Regulation.

    PubMed

    Sim, Aaron Y; Wallman, Karen E; Fairchild, Timothy J; Guelfi, Kym J

    2015-11-01

    An acute bout of high-intensity intermittent exercise suppresses ad libitum energy intake at the postexercise meal. The present study examined the effects of 12 wk of high-intensity intermittent exercise training (HIIT) compared with moderate-intensity continuous exercise training (MICT) on appetite regulation. Thirty overweight inactive men (body mass index, 27.2 ± 1.3 kg·m(-2); V˙O2peak, 35.3 ± 5.3 mL·kg(-1)·min(-1) were randomized to either HIIT or MICT (involving 12 wk of training, three sessions per week) or a control group (CON) (n = 10 per group). Ad libitum energy intake from a laboratory test meal was assessed after both a low-energy (847 kJ) and a high-energy preload (2438 kJ) before and after the intervention. Perceived appetite and appetite-related blood variables were also measured. There was no significant effect of the intervention period on energy intake at the test meal after the two different preloads (P ≥ 0.05). However, the 95% confidence interval indicated a clinically meaningful decrease in energy intake after the high-energy preload compared with the low-energy preload in response to HIIT (516 ± 395 kJ decrease), but not for MICT or CON, suggesting improved appetite regulation. This was not associated with alterations in the perception of appetite or the circulating concentration of a number of appetite-related peptides or metabolites, although insulin sensitivity was enhanced with HIIT only (P = 0.003). HIIT seems to benefit appetite regulation in overweight men. The mechanisms for this remain to be elucidated.

  8. High intensity proton injector for facility of antiproton and ion research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berezov, R., E-mail: r.berezov@gsi.de; Brodhage, R.; Fils, J.

    The high current ion source with the low energy beam transport (LEBT) will serve as injector into the proton LINAC to provide primary proton beam for the production of antiprotons. The pulsed ion source developed and built in CEA/Saclay operates with a frequency of 2.45 GHz based on ECR plasma production with two coils with 87.5 mT magnetic field necessary for the electron cyclotron resonance. The compact LEBT consists of two solenoids with a maximum magnetic field of 500 mT including two integrated magnetic steerers to adjust the horizontal and vertical beam positions. The total length of the compact LEBTmore » is 2.3 m and was made as short as possible to reduced emittance growth along the beam line. To measure ion beam intensity behind the pentode extraction system, between solenoids and at the end of the beam line, two current transformers and a Faraday cup are installed. To get information about the beam quality and position, the diagnostic chamber with different equipment will be installed between the two solenoids. This article reports the current status of the proton injector for the facility of antiproton and ion research.« less

  9. Comparative evaluation of the effects of high-intensity and low-intensity laser radiation on microcirculation among patients with knee arthritis

    NASA Astrophysics Data System (ADS)

    Kulchitskaya, D. B.; Konchugova, T. V.; E Fedorova, N.

    2017-04-01

    Sixty patients with knee arthritis aged from 40 to 75 years old were examined. The patients were randomly divided into two groups: 1st group (30 patients) received high intensity laser radiation; 2nd group (20 patients) received low intensity laser radiation. As a result of the conducted research it was found that high intensity laser radiation is more efficient and leads to more vivid positive changes in the microcirculation of patients with knee arthritis. The changes in microcirculation were based on the normalization of the myogenic and neurogenic tonus of the arterioles, strengthening oscillation of the endothelial range. As a result of local mechanisms activation of tissue blood flow there occurs adequate modulation of the microcirculatory bloodstream, which is aimed at the elimination of congestive phenomena in the capillary and venular level of the microcirculation bloodstream. We should note that in the long-term more significant were the positive changes in the state of the venular level of the microcirculation bloodstream. in constructing both.

  10. The relationship between aerobic fitness and recovery from high-intensity exercise in infantry soldiers.

    PubMed

    Hoffman, J R

    1997-07-01

    The relationship between aerobic fitness and recovery from high-intensity exercise was examined in 197 infantry soldiers. Aerobic fitness was determined by a maximal-effort, 2,000-m run (RUN). High-intensity exercise consisted of three bouts of a continuous 140-m sprint with several changes of direction. A 2-minute passive rest separated each sprint. A fatigue index was developed by dividing the mean time of the three sprints by the fastest time. Times for the RUN were converted into standardized T scores and separated into five groups (group 1 had the slowest run time and group 5 had the fastest run time). Significant differences in the fatigue index were seen between group 1 (4.9 +/- 2.4%) and groups 3 (2.6 +/- 1.7%), 4 (2.3 +/- 1.6%), and 5 (2.3 +/- 1.3%). It appears that recovery from high-intensity exercise is improved at higher levels of aerobic fitness (faster time for the RUN). However, as the level of aerobic fitness improves above the population mean, no further benefit in the recovery rate from high-intensity exercise is apparent.

  11. [Effect of high-intensity interval training on the reduction of glycosylated hemoglobin in type-2 diabetic adult patients].

    PubMed

    Aguilera Eguía, Raúl Alberto; Russell Guzmán, Javier Antonio; Soto Muñoz, Marcelo Enrique; Villegas González, Bastián Eduardo; Poblete Aro, Carlos Emilio; Ibacache Palma, Alejandro

    2015-03-05

    Type 2 diabetes mellitus is one of the major non-communicable chronic diseases in the world. Its prevalence in Chile is significant, and complications associated with this disease involve great costs, which is why prevention and treatment of this condition are essential. Physical exercise is an effective means for prevention and treatment of type 2 diabetes mellitus. The emergence of new forms of physical training, such as "high intensity interval training", presents novel therapeutic alternatives for patients and health care professionals. To assess the validity and applicability of the results regarding the effectiveness of high intensity interval training in reducing glycosylated hemoglobin in adult patients with type 2 diabetes mellitus and answer the following question: In subjects with type 2 diabetes, can the method of high intensity interval training compared to moderate intensity exercise decrease glycosylated hemoglobin? We performed a critical analysis of the article "Feasibility and preliminary effectiveness of high intensity interval training in type 2 diabetes". We found no significant differences in the amount of glycosylated hemoglobin between groups of high intensity interval training and moderate-intensity exercise upon completion of the study (p>0.05). In adult patients with type 2 diabetes mellitus, high intensity interval training does not significantly improve glycosylated hemoglobin levels. Despite this, the high intensity interval training method shows as much improvement in body composition and physical condition as the moderate intensity exercise program.

  12. Calculation of intensity of high energy muon groups observed deep underground

    NASA Technical Reports Server (NTRS)

    Vavilov, Y. N.; Dedenko, L. G.

    1985-01-01

    The intensity of narrow muon groups observed in Kolar Gold Field (KGF) at the depth of 3375 m.w.e. was calculated in terms of quark-gluon strings model for high energy hadron - air nuclei interactions by the method of direct modeling of nuclear cascade in the air and muon propagation in the ground for normal primary cosmic ray composition. The calculated intensity has been found to be approx. 10 to the 4 times less than one observed experimentally.

  13. Impact of high-intensity pulsed electric fields on bioactive compounds in Mediterranean plant-based foods.

    PubMed

    Elez-Martínez, Pedro; Soliva-Fortuny, Robert; Martín-Belloso, Olga

    2009-05-01

    Novel non-thermal processing technologies such as high-intensity pulsed electric field (HIPEF) treatments may be applied to pasteurize plant-based liquid foods as an alternative to conventional heat treatments. In recent years, there has been an increasing interest in HIPEF as a way of preserving and extending the shelf-life of liquid products without the quality damage caused by heat treatments. However, less attention has been paid to the effects of HIPEF on minor constituents of these products, namely bioactive compounds. This review is a state-of-the-art update on the effects of HIPEF treatments on health-related compounds in plants of the Mediterranean diet such as fruit juices, and Spanish gazpacho. The relevance of HIPEF-processing parameters on retaining plant-based bioactive compounds will be discussed.

  14. Sexual identity differences in high-intensity binge drinking: findings from a US national sample.

    PubMed

    Fish, Jessica N; Hughes, Tonda L; Russell, Stephen T

    2018-04-01

    To estimate sexual identity differences in high-intensity binge drinking. Cross-sectional US adult health survey from 2014 and 2015. US adults aged 18 and older (n = 215 684; n = 203 562 heterosexual, n = 2784 lesbian/gay, n = 2892 bisexual, n = 686 'other' and n = 1947 don't know/unsure). Self-reported past 30-day standard binge and high-intensity binge drinking. Standard binge drinking cut-off values were 4+/5+ drinks for women and men, respectively. High-intensity binge drinking was measured as two and three times the standard level (8+ and 12+ drinks for women and 10+ and 15+ drinks for men). Lesbian and bisexual women were more likely than heterosexual women to report consuming 4+ drinks (adjusted odds ratio [aOR] =1.57, confidence interval [CI] = 1.18, 2.09 and aOR = 1.83, CI = 1.45, 2.30 for lesbian and bisexual women, respectively); 8+ drinks (aOR = 3.86, CI = 2.39, 6.24, aOR = 2.07, CI = 1.39, 3.07); and 12+ drinks (aOR = 3.81, CI = 1.77, 8.19, aOR = 2.54, CI = 1.25, 5.14) on a single occasion in the past 30 days. Generally, gay and bisexual men were no more likely than heterosexual men to report standard or high-intensity binge drinking. However, bisexual men were more likely than heterosexual men to consume 15+ drinks (aOR = 1.76, 95% CI = 1.01, 3.06). Rates of standard and high-intensity binge drinking were similar between heterosexual and unsure men and women. Men and women who indicated 'other' sexual identities were generally less likely than heterosexuals to report standard and high-intensity binge drinking, with the exception of 4+ drinks for women and 10+ drinks for men. In the United States, sexual minority women are more likely, and sexual minority men are equally likely, to drink at standard and high-intensity binge drinking levels as their heterosexual counterparts. © 2017 Society for the Study of Addiction.

  15. Examining Lactate Changes during High Intensity Spinning® Training

    ERIC Educational Resources Information Center

    Ipekoglu, Gökhan; Baynaz, Kadir; Mor, Ahmet; Acar, Kürsat; Arslanoglu, Cansel; Arslanoglu, Erkal

    2018-01-01

    The aim of the study was to examine the changes in the acute blood lactate levels of elite taekwondo players when carrying out high-intensity interval training on Spinning® bikes. Twenty elite-level taekwondo athletes participated in the study. The subjects were selected from athletes who had been competitors for at least six years. Their average…

  16. High Intensity Focused Ultrasound Tumor Therapy System and Its Application

    NASA Astrophysics Data System (ADS)

    Sun, Fucheng; He, Ye; Li, Rui

    2007-05-01

    At the end of last century, a High Intensity Focused Ultrasound (HIFU) tumor therapy system was successfully developed and manufactured in China, which has been already applied to clinical therapy. This article aims to discuss the HIFU therapy system and its application. Detailed research includes the following: power amplifiers for high-power ultrasound, ultrasound transducers with large apertures, accurate 3-D mechanical drives, a software control system (both high-voltage control and low-voltage control), and the B-mode ultrasonic diagnostic equipment used for treatment monitoring. Research on the dosage of ultrasound required for tumour therapy in multiple human cases has made it possible to relate a dosage formula, presented in this paper, to other significant parameters such as the volume of thermal tumor solidification, the acoustic intensity (I), and the ultrasound emission time (tn). Moreover, the HIFU therapy system can be applied to the clinical treatment of both benign and malignant tumors in the pelvic and abdominal cavity, such as uterine fibroids, liver cancer and pancreatic carcinoma.

  17. Groundwater quality assessment and pollution source apportionment in an intensely exploited region of northern China.

    PubMed

    Zhang, Qianqian; Wang, Huiwei; Wang, Yanchao; Yang, Mingnan; Zhu, Liang

    2017-07-01

    Deterioration in groundwater quality has attracted wide social interest in China. In this study, groundwater quality was monitored during December 2014 at 115 sites in the Hutuo River alluvial-pluvial fan region of northern China. Results showed that 21.7% of NO 3 - and 51.3% of total hardness samples exceeded grade III of the national quality standards for Chinese groundwater. In addition, results of gray relationship analysis (GRA) show that 64.3, 10.4, 21.7, and 3.6% of samples were within the I, II, IV, and V grades of groundwater in the Hutuo River region, respectively. The poor water quality in the study region is due to intense anthropogenic activities as well as aquifer vulnerability to contamination. Results of principal component analysis (PCA) revealed three major factors: (1) domestic wastewater and agricultural runoff pollution (anthropogenic activities), (2) water-rock interactions (natural processes), and (3) industrial wastewater pollution (anthropogenic activities). Using PCA and absolute principal component scores-multivariate linear regression (APCS-MLR), results show that domestic wastewater and agricultural runoff are the main sources of groundwater pollution in the Hutuo River alluvial-pluvial fan area. Thus, the most appropriate methods to prevent groundwater quality degradation are to improve capacities for wastewater treatment and to optimize fertilization strategies.

  18. Relationship between anxiety, depression and quality of life with the intensity of reflex sweating after thoracoscopic sympathectomy for treatment of primary hyperhidrosis.

    PubMed

    Dias, Luciara Irene DE Nadai; Miranda, Eliana Cristina Martins; Toro, Ivan Felizardo Contrera; Mussi, Ricardo Kalaf

    2016-01-01

    to compare the intensity of reflex sweating with the degree of anxiety and its interference in the quality of life of patients undergoing Thoracoscopic (VATS) sympathectomy in the pre- and postoperative period. we evaluated 54 patients with a mean age of 26 years (16-49 years) undergoing sympathectomy in the R3-R4 level. We applied two questionnaires at three different times: "Quality of life in patients with primary hyperhidrosis" and "Scale for anxiety and depression". of the patients studied, 93% showed significant improvement in quality of life 30 days after surgery, the effects remaining after six months. There were no postoperative complications. The patient's level of anxiety is highly correlated with the intensity of reflex sweating after 30 and 180 days. Thoracoscopic sympathectomy improves quality of life of patients with primary hyperhidrosis, even with the emergence of reflex sweating. Anxiety directly relates to the intensity of reflex sweating, without compromising the degree of patient satisfaction. avaliar a intensidade de sudorese reflexa com o grau de ansiedade e sua interferência na qualidade de vida de indivíduos submetidos à simpatectomia por videotoracoscopia nos períodos pré e pós-operatório. foram avaliados 54 pacientes com média de idade de 26 anos (16 a 49 anos), submetidos à simpatectomia em nível R3-R4. Dois questionários foram aplicados em três momentos diferentes: "Qualidade de vida em pacientes com hiperidrose primária e "Escala para ansiedade e depressão". dos pacientes estudados, 93% mostrou melhora significativa na qualidade de vida após 30 dias da cirurgia, com os efeitos remanescentes após seis meses. Não houve complicações pós-operatórias. A análise mostrou que o nível de ansiedade do paciente é altamente correlacionado com a intensidade da sudorese reflexa após 30 e 180 dias. a simpatectomia torácica por videotoracoscopia melhora a qualidade de vida de pacientes com hiperidrose primária, mesmo com o

  19. Interleukin-6 and associated cytokine responses to an acute bout of high-intensity interval exercise: the effect of exercise intensity and volume.

    PubMed

    Cullen, Tom; Thomas, Andrew W; Webb, Richard; Hughes, Michael G

    2016-08-01

    Acute increases in interleukin (IL)-6 following prolonged exercise are associated with the induction of a transient anti-inflammatory state (e.g., increases in IL-10) that is partly responsible for the health benefits of regular exercise. The purposes of this study were to investigate the IL-6-related inflammatory response to high-intensity interval exercise (HIIE) and to determine the impact of exercise intensity and volume on this response. Ten participants (5 males and 5 females) completed 3 exercise bouts of contrasting intensity and volume (LOW, MOD, and HIGH). The HIGH protocol was based upon standard HIIE protocols, while the MOD and LOW protocols were designed to enable a comparison of exercise intensity and volume with a fixed duration. Inflammatory cytokine concentrations were measured in plasma (IL-6, IL-10) and also determined the level of gene expression (IL-6, IL-10, and IL-4R) in peripheral blood. The plasma IL-6 response to exercise (reported as fold changes) was significantly greater in HIGH (2.70 ± 1.51) than LOW (1.40 ± 0.32) (P = 0.04) and was also positively correlated to the mean exercise oxygen uptake (r = 0.54, P < 0.01). However, there was no change in anti-inflammatory IL-10 or IL-4R responses in plasma or at the level of gene expression. HIIE caused a significant increase in IL-6 and was greater than that seen in low-intensity exercise of the same duration. The increases in IL-6 were relatively small in magnitude, and appear to have been insufficient to induce the acute systemic anti-inflammatory effects, which are evident following longer duration exercise.

  20. The different effects of high intensity interval training and moderate intensity interval training for weightlessness countermeasures

    NASA Astrophysics Data System (ADS)

    Wang, Lin-Jie; Cheng, Tan; Zhi-Li, Li; Hui-juan, Wang; Wen-juan, Chen; Jianfeng, Zhang; Desheng, Wang; Dongbin, Niu; Qi, Zhao; Chengjia, Yang; Yanqing, Wang

    High intensity interval training (HIIT) has been demonstrated to improve performance in a relatively short training period. But the difference between high intensity interval training and moderate intensity interval training (MIIT) in simulated weightlessness still has not been well studied. This study sought to characterize the difference between 6 weeks high intensity interval training and moderate intensity interval training under reduced weight (RW) gait training device and zero-gravity locomotion system (ZLS). Twenty-three subjects (14M/4F, 32.5±4.5 years) volunteered to participate. They were divided into three groups, that were MITT (alternating 2 min at 40% VO _{2} peak and 2 min at 60% VO _{2} peak for 30min, five days per week) RW group (n=8), HITT (alternating 2 min at 40% VO _{2} peak and 2 min at 90% VO _{2} peak for 30min, three days per week) RW group (n=8) and HITT ZLS group (n=7). The Z-axis load used in RW group was 80% body weight (BW) and in ZLS was 100% BW. Cardiopulmonary function was measured before, after 4-week training and after 6-week training. Isokinetic knee extension-flexion test at 60(°) deg/s and 180(°) deg/s were performed before and after the 6-week training, and isometric knee extension-flexion test at 180(°) deg/s was also examined at the same time. It was found that the VO _{2} peaks, metabolic equivalent (MET), Speedmax and respiratory exchange ratio (RER) were significantly increased after 4 and 6-week training in all three groups and no significant group difference were detected. The peak torque at 60(°) deg/s for right knee flexion were significantly increased after 6 week-training in all three groups, and only in HITT RW group the total power at 60(°) deg/s for right knee flexion enhanced. The total power and average power at 60(°) deg/s for right knee extension decreased significantly after 6-week training in all three groups. The peak torque at 60(°) deg/s for right knee extension in MIIT RW group was

  1. Rotation placements help students' understanding of intensive care.

    PubMed

    Abbott, Lisa

    2011-07-01

    It is vital that children's nursing students are fit for practice when they qualify and are able to meet various essential skills as defined by the Nursing and Midwifery Council (NMC). To gain the knowledge and skills required, students need placements in areas where high dependency and potentially intensive care are delivered. Efforts to maximise the number of students experiencing intensive care as a placement have led to the development of the paediatric intensive care unit (PICU) rotation, increasing placements on the PICU from 5 to 40 per cent of the student cohort per year. The lecturer practitioner organises the rotation, providing credible links between university and practice areas, while supporting students and staff in offering a high-quality placement experience. Students say the rotation offers a positive insight into PICU nursing, helping them develop knowledge and skills in a technical area and creating an interest in this specialty.

  2. Highly qualified does not equal high quality: A study of urban stakeholders' perceptions of quality in science teaching

    NASA Astrophysics Data System (ADS)

    Miranda, Rommel Joseph

    By employing qualitative methods, this study sought to determine the perceptions that urban stakeholders hold about what characteristics should distinguish a high school science teacher whom they would consider to demonstrate high quality in science teaching. A maximum variation sample of six science teachers, three school administrators, six parents and six students from a large urban public school district were interviewed using semi-structured, in-depth interview techniques. From these data, a list of observable characteristics which urban stakeholders hold as evidence of high quality in science teaching was generated. Observational techniques were utilized to determine the extent to which six urban high school science teachers, who meet the NCLB Act criteria for being "highly qualified", actually possessed the characteristics which these stakeholders hold as evidence of high quality in science teaching. Constant comparative analysis was used to analyze the data set. The findings suggest that urban stakeholders perceive that a high school science teacher who demonstrates high quality in science teaching should be knowledgeable about their subject matter, their student population, and should be resourceful; should possess an academic background in science and professional experience in science teaching; should exhibit professionalism, a passion for science and teaching, and a dedication to teaching and student learning; should be skillful in planning and preparing science lessons and in organizing the classroom, in presenting the subject matter to students, in conducting a variety of hands-on activities, and in managing a classroom; and should assess whether students complete class goals and objectives, and provide feedback about grades for students promptly. The findings further reveal that some of the urban high school science teachers who were deemed to be "highly qualified", as defined by the NCLB Act, engaged in practices that threatened quality in science

  3. Reconstruction of perfect ZnO nanowires facets with high optical quality

    NASA Astrophysics Data System (ADS)

    Zehani, E.; Hassani, S.; Lusson, A.; Vigneron, J.; Etcheberry, A.; Galtier, P.; Sallet, V.

    2017-07-01

    ZnO nanowires were grown on sapphire substrates using metalorganic chemical vapor deposition. The samples were subsequently annealed under zinc pressure in a vacuum-sealed ampoule, at temperature ranging from 500 to 800 °C. The originality and the main motivation to provide a zinc-rich atmosphere were to prevent the out-diffusion of zinc from the nanowires. In doing so, the perfect structural properties and the morphology of the nanowires are kept. Interestingly, photoluminescence experiments performed on nanowires annealed in a narrow window of temperature [580-620 °C] show a spectacular improvement of the optical quality, as transitions commonly observable in high quality bulk samples are found. In addition, the intensity of the so-called "surface excitons" (SX) is strongly decreased. To accurately investigate the chemical modifications of the surface, XPS experiments were carried out and show that zinc hydroxide species and/or Zn(OH)2 sublayer were partially removed from the surface. These results suggest that the annealing process in zinc vapor helps to properly reconstruct the surface of ZnO nanowires, and improves the optical quality of their core. Such a thermal treatment at moderate temperature should be beneficial to nanodevices involving surface reaction, e.g. gas sensors.

  4. The feasibility and effectiveness of high-intensity boxing training versus moderate-intensity brisk walking in adults with abdominal obesity: a pilot study.

    PubMed

    Cheema, Birinder S; Davies, Timothy B; Stewart, Matthew; Papalia, Shona; Atlantis, Evan

    2015-01-01

    High-intensity interval training (HIIT) performed on exercise cycle or treadmill is considered safe and often more beneficial for fat loss and cardiometabolic health than moderate-intensity continuous training (MICT). The aim of this pilot study was to assess the feasibility and effectiveness of a 12-week boxing training (HIIT) intervention compared with an equivalent dose of brisk walking (MICT) in obese adults. Men and women with abdominal obesity and body mass index >25 kg/m(2) were randomized to either a boxing group or a brisk walking (control) group for 12 weeks. Each group engaged in 4 training sessions per week, equated for total physical activity. Feasibility outcomes included recruitment rates, assessment of training intensities, adherence and adverse events. Effectiveness was assessed pre and post intervention via pertinent obesity-, cardiovascular-, and health-related quality of life (HRQoL) outcomes. Nineteen individuals expressed an interest and 63% (n = 12) consented. Recruitment was slower than anticipated (1.3 participants/week). The boxing group trained at a significantly higher intensity each week versus the brisk walking group (p < 0.05). Two participants in the boxing group experienced an adverse event; both continued to exercise with modifications to the exercise program. No other adverse events were noted. The boxing group attended more sessions (79% vs. 55%) and had a lower attrition rate (n = 0 vs. n = 2) than the walking group. Analysis of covariance revealed that the boxing group significantly improved body fat percentage (p = 0.047), systolic blood pressure (p = 0.026), augmentation index (AIx; p < 0.001), absolute VO2max (p = 0.015), and Physical Functioning (p = 0.042) and Vitality (p = 0.024) domains of HRQoL over time. The walking group did not improve any clinical outcomes, and experienced a worsening of Vitality (p = 0.043). Boxing training (HIIT) in adults with abdominal obesity is

  5. High-intensity exercise training for the prevention of type 2 diabetes mellitus.

    PubMed

    Rynders, Corey A; Weltman, Arthur

    2014-02-01

    Aerobic exercise training and diet are recommended for the primary prevention of type 2 diabetes mellitus and cardiovascular disease. The American Diabetes Association (ADA) recommends that adults with prediabetes engage in ≥ 150 minutes per week of moderate activity and target a 7% weight loss. However, traditional moderate-intensity (MI) exercise training programs are often difficult to sustain for prediabetic adults; a commonly cited barrier to physical activity in this population is the "lack of time" to exercise. When matched for total energy expenditure, high-intensity (HI) exercise training has a lower overall time commitment compared with traditional low-intensity (LI) or MI exercise training. Several recent studies comparing HI exercise training with LI and MI exercise training reported that HI exercise training improves skeletal muscle metabolic control and cardiovascular function in a comparable and/or superior way relative to LI and MI exercise training. Although patients can accrue all exercise benefits by performing LI or MI activities such as walking, HI activities represent a time-efficient alternative to meeting physical activity guidelines. High-intensity exercise training is a potent tool for improving cardiometabolic risk for prediabetic patients with limited time and may be prescribed when appropriate.

  6. Effects of high intensity interval training versus moderate intensity continuous training on the reduction of oxidative stress in type 2 diabetic adult patients: CAT.

    PubMed

    Poblete Aro, Carlos Emilio; Russell Guzmán, Javier Antonio; Soto Muñoz, Marcelo Enrique; Villegas González, Bastián Eduardo

    2015-08-13

    Oxidative stress is caused by an imbalance between an excessive production of reactive oxygen species and/or a deficiency in the level of endogenous and exogenous antioxidant defenses. The presence of reactive oxygen species in large concentrations and for long periods is associated with the occurrence of various diseases, including type 2 diabetes mellitus. Exercise represents an effective means for the prevention and treatment of type 2 diabetes mellitus, and is also able to reduce long-term oxidative stress levels. High-intensity interval training has shown to be an efficient and viable option for type 2 diabetes mellitus control. In turn, high-intensity interval training seems to have positive effects on oxidative stress levels by increasing levels of endogenous antioxidants. To assess the validity and applicability of the results regarding the effectiveness of high-intensity interval training compared to moderate intensity continuous training to reduce oxidative stress in patients with type 2 diabetes mellitus and to answer the following question: In adults with type 2 diabetes mellitus, can the method of high-intensity interval training, compared to moderate intensity continuous training reduce oxidative stress levels? We performed a critical analysis of the article "Continuous training vs Interval training in glycemic control and macro and microvascular reactivity in patients with type 2 diabetes". No statistically significant differences were observed in concentrations of superoxide dismutase in any of the experimental groups. Only in the interval group a decrease in malondialdehyde regarding control group and baseline (p<0.05) was observed. In addition, only in the interval group there was an increase in glutathione peroxidase compared to the group of continuous aerobic training and baseline (p<0.05). Nitric oxide showed a significant increase regarding the control, continuous aerobic group and baseline (p<0.05) in the interval training group. Despite the

  7. [Applying back massage protocol to promote an intensive care unit patient's quality of sleep].

    PubMed

    Fang, Chiu-Shu; Liu, Chin-Fang

    2006-12-01

    This case report concerns the nursing experience of applying back massage to a patient in an intensive care unit (ICU) from 10 May, 2005, in order to improve the patient's quality of sleep. In order to collect information about his quality of sleep of the patient, the author used observation, interview and a Richards-Campbell sleep questionnaire (RCSQ). It was observed that, before massage, the patient's sleep quality was poor, which wa why the protocol with back massage was proposed. The results after back massage was applied that heart beat, respiration. oxygen saturation and blood pressure were not significantly improved. This was probably related to the patient's worry about having his endotracheal tube removed. The patient's perception of sleep, indeed, was obviously improved, a result which may have been related to his/her perception of comfort and care from the nurse. Applying back massage to an ICU patient may therefore be regarded as helpful improving the patient's sleep quality. It is hoped that this case report may serve as a positive reference for health care providers so that it may help patients to recover fully through rest and sleep. Since this report concerned only one patient, however, to understand the real outcome of how back massage could improve the quality of sleep of ICU patients, research is planned on the use of back massage protocol on a large number os such patients.

  8. A novel type of very long baseline astronomical intensity interferometer

    NASA Astrophysics Data System (ADS)

    Borra, Ermanno F.

    2013-12-01

    This article presents a novel type of very long baseline astronomical interferometer that uses the fluctuations, as a function of time, of the intensity measured by a quadratic detector, which is a common type of astronomical detector. The theory on which the technique is based is validated by laboratory experiments. Its outstanding principal advantages comes from the fact that the angular structure of an astronomical object is simply determined from the visibility of the minima of the spectrum of the intensity fluctuations measured by the detector, as a function of the frequency of the fluctuations, while keeping the spacing between mirrors constant. This would allow a simple setup capable of high angular resolutions because it could use an extremely large baseline. Another major interest is that it allows for a more efficient use of telescope time because observations at a single baseline are sufficient, while amplitude and intensity interferometers need several observations at different baselines. The fact that one does not have to move the telescopes would also allow detecting faster time variations because having to move the telescopes sets a lower limit to the time variations that can be detected. The technique uses wave interaction effects and thus has some characteristics in common with intensity interferometry. A disadvantage of the technique, like in intensity interferometry, is that it needs strong sources if observing at high frequencies (e.g. the visible). This is a minor disadvantage in the radio region. At high frequencies, this disadvantage is mitigated by the fact that, like in intensity interferometry, the requirements of the optical quality of the mirrors used are far less severe than in amplitude interferometry so that poor quality large reflectors (e.g. Cherenkov telescopes) can be used in the optical region.

  9. Effects of different doses of high-speed resistance training on physical performance and quality of life in older women: a randomized controlled trial

    PubMed Central

    Ramirez-Campillo, Rodrigo; Diaz, Daniela; Martinez-Salazar, Cristian; Valdés-Badilla, Pablo; Delgado-Floody, Pedro; Méndez-Rebolledo, Guillermo; Cañas-Jamet, Rodrigo; Cristi-Montero, Carlos; García-Hermoso, Antonio; Celis-Morales, Carlos; Moran, Jason; Buford, Thomas W; Rodriguez-Mañas, Leocadio; Alonso-Martinez, Alicia M; Izquierdo, Mikel

    2016-01-01

    Objective This study aimed to compare the effects of two frequencies of high-speed resistance training (HSRT) on physical performance and quality of life of older women. Methods A total of 24 older women participated in a 12-week HSRT program composed of either two or three sessions/week (equated for volume and intensity). Women were randomized into three arms: a control group (CG, n=8), a resistance training group performing two sessions/week (RT2, n=8), and a resistance training group performing three sessions/week (RT3, n=8). The training program for both experimental groups included exercises that required high-speed concentric muscle actions. Results No baseline differences were observed among groups. Compared with the CG, both training groups showed similar small to moderate improvements (P<0.05) in muscle strength, power, functional performance, balance, and quality of life. Conclusion These results suggest that equated for volume and intensity, two and three training sessions/week of HSRT are equally effective for improving physical performance and quality of life of older women. PMID:28008239

  10. Effects of different doses of high-speed resistance training on physical performance and quality of life in older women: a randomized controlled trial.

    PubMed

    Ramirez-Campillo, Rodrigo; Diaz, Daniela; Martinez-Salazar, Cristian; Valdés-Badilla, Pablo; Delgado-Floody, Pedro; Méndez-Rebolledo, Guillermo; Cañas-Jamet, Rodrigo; Cristi-Montero, Carlos; García-Hermoso, Antonio; Celis-Morales, Carlos; Moran, Jason; Buford, Thomas W; Rodriguez-Mañas, Leocadio; Alonso-Martinez, Alicia M; Izquierdo, Mikel

    2016-01-01

    This study aimed to compare the effects of two frequencies of high-speed resistance training (HSRT) on physical performance and quality of life of older women. A total of 24 older women participated in a 12-week HSRT program composed of either two or three sessions/week (equated for volume and intensity). Women were randomized into three arms: a control group (CG, n=8), a resistance training group performing two sessions/week (RT2, n=8), and a resistance training group performing three sessions/week (RT3, n=8). The training program for both experimental groups included exercises that required high-speed concentric muscle actions. No baseline differences were observed among groups. Compared with the CG, both training groups showed similar small to moderate improvements ( P <0.05) in muscle strength, power, functional performance, balance, and quality of life. These results suggest that equated for volume and intensity, two and three training sessions/week of HSRT are equally effective for improving physical performance and quality of life of older women.

  11. Can high-intensity exercise be more pleasant?: attentional dissociation using music and video.

    PubMed

    Jones, Leighton; Karageorghis, Costas I; Ekkekakis, Panteleimon

    2014-10-01

    Theories suggest that external stimuli (e.g., auditory and visual) may be rendered ineffective in modulating attention when exercise intensity is high. We examined the effects of music and parkland video footage on psychological measures during and after stationary cycling at two intensities: 10% of maximal capacity below ventilatory threshold and 5% above. Participants (N = 34) were exposed to four conditions at each intensity: music only, video only, music and video, and control. Analyses revealed main effects of condition and exercise intensity for affective valence and perceived activation (p < .001), state attention (p < .05), and exercise enjoyment (p < .001). The music-only and music-and-video conditions led to the highest valence and enjoyment scores during and after exercise regardless of intensity. Findings indicate that attentional manipulations can exert a salient influence on affect and enjoyment even at intensities slightly above ventilatory threshold.

  12. DIN 1.7035 Steel Modification with High Intensity Nitrogen Ion Implantation

    NASA Astrophysics Data System (ADS)

    Ryabchikov, A. I.; Sivin, D. O.; Anan'in, P. S.; Ivanova, A. I.; Uglov, V. V.; Korneva, O. S.

    2018-06-01

    The paper presents research results on the formation of deep ion-modified layers of the grade DIN 1.7035 alloy steel due to a high intensity, repetitively-pulsed nitrogen ion beams with the ion current density of up to 0.5 A/cm2. The formation of a low-energy, high intensity nitrogen ion beam is based on a plasma immersion ion extraction followed by the ballistic focusing in the equipotential drift region. The nitrogen ion implantation in steel specimens is performed at a 1.2 keV energy and 450, 500, 580 and 650°C temperatures during 60 minutes. The morphology, elementary composition and mechanical properties are investigated in deep layers of steel specimens alloyed with nitrogen ions.

  13. High quality transmission Kikuchi diffraction analysis of deformed alloys - Case study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tokarski, Tomasz, E-mail: tokarski@agh.edu.pl

    Modern scanning electron microscopes (SEM) equipped with thermally assisted field emission guns (Schottky FEG) are capable of imaging with a resolution in the range of several nanometers or better. Simultaneously, the high electron beam current can be used, which enables fast chemical and crystallographic analysis with a higher resolution than is normally offered by SEM with a tungsten cathode. The current resolution that limits the EDS and EBSD analysis is related to materials' physics, particularly to the electron-specimen interaction volume. The application of thin, electron-transparent specimens, instead of bulk samples, improves the resolution and allows for the detailed analysis ofmore » very fine microstructural features. Beside the typical imaging mode, it is possible to use a standard EBSD camera in such a configuration that only transmitted and scattered electrons are detected. This modern approach was successfully applied to various materials giving rise to significant resolution improvement, especially for the light element magnesium based alloys. This paper presents an insight into the application of the transmission Kikuchi diffraction (TKD) technique applied to the most troublesome, heavily-deformed materials. In particular, the values of the highest possible acquisition rates for high resolution and high quality mapping were estimated within typical imaging conditions of stainless steel and magnesium-yttrium alloy. - Highlights: •Monte Carlo simulations were used to simulate EBSD camera intensity for various measuring conditions. •Transmission Kikuchi diffraction parameters were evaluated for highly deformed, light and heavy elements based alloys. •High quality maps with 20 nm spatial resolution were acquired for Mg and Fe based alloys. •High speed TKD measurements were performed at acquisition rates comparable to the reflection EBSD.« less

  14. Low- Versus High-Intensity Plyometric Exercise During Rehabilitation After Anterior Cruciate Ligament Reconstruction.

    PubMed

    Chmielewski, Terese L; George, Steven Z; Tillman, Susan M; Moser, Michael W; Lentz, Trevor A; Indelicato, Peter A; Trumble, Troy N; Shuster, Jonathan J; Cicuttini, Flavia M; Leeuwenburgh, Christiaan

    2016-03-01

    Plyometric exercise is used during rehabilitation after anterior cruciate ligament (ACL) reconstruction to facilitate the return to sports participation. However, clinical outcomes have not been examined, and high loads on the lower extremity could be detrimental to knee articular cartilage. To compare the immediate effect of low- and high-intensity plyometric exercise during rehabilitation after ACL reconstruction on knee function, articular cartilage metabolism, and other clinically relevant measures. Randomized controlled trial; Level of evidence, 2. Twenty-four patients who underwent unilateral ACL reconstruction (mean, 14.3 weeks after surgery; range, 12.1-17.7 weeks) were assigned to 8 weeks (16 visits) of low- or high-intensity plyometric exercise consisting of running, jumping, and agility activities. Groups were distinguished by the expected magnitude of vertical ground-reaction forces. Testing was conducted before and after the intervention. Primary outcomes were self-reported knee function (International Knee Documentation Committee [IKDC] subjective knee form) and a biomarker of articular cartilage degradation (urine concentrations of crosslinked C-telopeptide fragments of type II collagen [uCTX-II]). Secondary outcomes included additional biomarkers of articular cartilage metabolism (urinary concentrations of the neoepitope of type II collagen cleavage at the C-terminal three-quarter-length fragment [uC2C], serum concentrations of the C-terminal propeptide of newly formed type II collagen [sCPII]) and inflammation (tumor necrosis factor-α), functional performance (maximal vertical jump and single-legged hop), knee impairments (anterior knee laxity, average knee pain intensity, normalized quadriceps strength, quadriceps symmetry index), and psychosocial status (kinesiophobia, knee activity self-efficacy, pain catastrophizing). The change in each measure was compared between groups. Values before and after the intervention were compared with the groups

  15. Muscle contractile characteristics: relationship to high-intensity exercise.

    PubMed

    Morris, Martyn G; Dawes, Helen; Howells, Ken; Scott, Oona M; Cramp, Mary; Izadi, Hooshang

    2010-09-01

    We investigated the relationship between muscle contractile characteristics, collected using percutaneous electrical stimulation, and high-intensity exercise performance. Seventeen participants performed a muscle performance test for the calculation of rate of torque development (RTD), rate of relaxation (RR(1/2)), rate of fatigue and fatigue resistance. On a second visit the participants completed a Wingate cycle ergometer test with peak power, mean power, fatigue index and fatigue rate calculated. The muscle fatigue index related significantly to the WAnT fatigue index and fatigue rate (p < 0.01). The change in rate of torque development (%DeltaRTD) was also related significantly to the fatigue rate (W/s) during the WAnT. Subjects displaying the greatest reduction in RTD had the greatest fatigue rate during the WAnT and greater fatigue during the electrical stimulation protocol. There were no significant relationships between peak (r 0.36; p > 0.01) or mean power (r -0.11, p > 0.01) with any of the muscle performance measures. These findings demonstrate that muscle contractile characteristics, elicited during standardised in vivo electrical stimulation, relate to performance during a Wingate anaerobic test. They suggest that muscle contraction characteristics play an important role in high-intensity exercise performance and indicate that electrical stimulation protocols can be a useful additional tool to explore muscle contraction characteristics in relation to exercise performance and trainability.

  16. Intensity of Anxiety and Depression in Patients with Lung Cancer in Relation to Quality of Life.

    PubMed

    Polański, Jacek; Chabowski, Mariusz; Chudiak, Anna; Uchmanowicz, Bartosz; Janczak, Dariusz; Rosińczuk, Joanna; Mazur, Grzegorz

    2018-01-01

    Psychological factors, such as the anxiety and depression, which often occur in patients with lung cancer might negatively influence their quality of life. The aim of the study was to evaluate the effect of anxiety and depression in lung cancer patients on quality of life. The study included 180 lung patients of the mean age of 62.7 ± 9.7 years. The following scales were employed in the study: Quality of Life Questionnaire QLQ-C30 and LC13 scale, and Hospital Anxiety and Depression scale (HADS). The overall score of quality of life measured by QLQ-C30 was 47.1 ± 23.4 points on a hundred-point scale. Anxiety was diagnosed in 67 patients (37.2%) and depression in 75 patients (41.7%) by HADS. Quality of life was significantly worse in case of anxiety and depression (p < 0.05), which negatively influenced both functional and symptom intensity scales measured with QLQ-C30 and QLQ-LC13. We conclude that early identification of anxiety and depression may help in therapeutic decision-making and may be a useful predictive factor in lung cancer patients.

  17. Assuring quality in high-consequence engineering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoover, Marcey L.; Kolb, Rachel R.

    2014-03-01

    In high-consequence engineering organizations, such as Sandia, quality assurance may be heavily dependent on staff competency. Competency-dependent quality assurance models are at risk when the environment changes, as it has with increasing attrition rates, budget and schedule cuts, and competing program priorities. Risks in Sandia's competency-dependent culture can be mitigated through changes to hiring, training, and customer engagement approaches to manage people, partners, and products. Sandia's technical quality engineering organization has been able to mitigate corporate-level risks by driving changes that benefit all departments, and in doing so has assured Sandia's commitment to excellence in high-consequence engineering and national service.

  18. Improvement in surface fatigue life of hardened gears by high-intensity shot peening

    NASA Astrophysics Data System (ADS)

    Townsend, Dennis P.

    1992-04-01

    Two groups of carburized, hardened, and ground spur gears that were manufactured from the same heat vacuum induction melted vacuum arc melted (VIM VAR) AISI 9310 steel were endurance tested for surface fatigue. Both groups were manufactured with a standard ground 16 rms surface finish. One group was subjected to a shot peening (SP) intensity of 7 to 9A, and the second group was subjected to a SP intensity of 15 to 17A. All gears were honed after SP to a surface finish of 16 rms. The gear pitch diameter was 8.89 cm. Test conditions were a maximum Hertz stress of 1.71 GPa, a gear temperature of 350 K, and a speed of 10000 rpm. The lubricant used for the tests was a synthetic paraffinic oil with an additive package. The following results were obtained: The 10 pct. surface fatigue (pitting) life of the high intensity (15 to 17A) SPed gears was 2.15 times that of the medium intensity (7 to 9A) SPed gears, the same as that calculated from measured residual stress at a depth of 127 microns. The measured residual stress for the high intensity SPed gears was 57 pct. higher than that for the medium intensity SPed gears at a depth of 127 microns and 540 pct. higher at a depth of 51 microns.

  19. Improvement in surface fatigue life of hardened gears by high-intensity shot peening

    NASA Technical Reports Server (NTRS)

    Townsend, Dennis P.

    1992-01-01

    Two groups of carburized, hardened, and ground spur gears that were manufactured from the same heat vacuum induction melted vacuum arc melted (VIM VAR) AISI 9310 steel were endurance tested for surface fatigue. Both groups were manufactured with a standard ground 16 rms surface finish. One group was subjected to a shot peening (SP) intensity of 7 to 9A, and the second group was subjected to a SP intensity of 15 to 17A. All gears were honed after SP to a surface finish of 16 rms. The gear pitch diameter was 8.89 cm. Test conditions were a maximum Hertz stress of 1.71 GPa, a gear temperature of 350 K, and a speed of 10000 rpm. The lubricant used for the tests was a synthetic paraffinic oil with an additive package. The following results were obtained: The 10 pct. surface fatigue (pitting) life of the high intensity (15 to 17A) SPed gears was 2.15 times that of the medium intensity (7 to 9A) SPed gears, the same as that calculated from measured residual stress at a depth of 127 microns. The measured residual stress for the high intensity SPed gears was 57 pct. higher than that for the medium intensity SPed gears at a depth of 127 microns and 540 pct. higher at a depth of 51 microns.

  20. Time-Course Changes of Oxidative Stress Response to High-Intensity Discontinuous Training versus Moderate-Intensity Continuous Training in Masters Runners

    PubMed Central

    Vezzoli, Alessandra; Pugliese, Lorenzo; Marzorati, Mauro; Serpiello, Fabio Rubens; La Torre, Antonio; Porcelli, Simone

    2014-01-01

    Beneficial systemic effects of regular physical exercise have been demonstrated to reduce risks of a number of age-related disorders. Antioxidant capacity adaptations are amongst these fundamental changes in response to exercise training. However, it has been claimed that acute physical exercise performed at high intensity (>60% of maximal oxygen uptake) may result in oxidative stress, due to reactive oxygen species being generated excessively by enhanced oxygen consumption. The aim of this study was to evaluate the effect of high-intensity discontinuous training (HIDT), characterized by repeated variations of intensity and changes of redox potential, on oxidative damage. Twenty long-distance masters runners (age 47.8±7.8 yr) on the basis of the individual values of gas exchange threshold were assigned to a different 8-weeks training program: continuous moderate-intensity training (MOD, n = 10) or HIDT (n = 10). In both groups before (PRE) and after (POST) training we examined the following oxidative damage markers: thiobarbituric acid reactive substances (TBARS) as marker of lipid peroxidation; protein carbonyls (PC) as marker of protein oxidation; 8-hydroxy-2-deoxy-guanosine (8-OH-dG) as a biomarker of DNA base modifications; and total antioxidant capacity (TAC) as indicator of the overall antioxidant system. Training induced a significant (p<0.05) decrease in resting plasma TBARS concentration in both MOD (7.53±0.30 and 6.46±0.27 µM, PRE and POST respectively) and HIDT (7.21±0.32 and 5.85±0.46 µM, PRE and POST respectively). Resting urinary 8-OH-dG levels were significantly decreased in both MOD (5.50±0.66 and 4.16±0.40 ng mg−1creatinine, PRE and POST respectively) and HIDT (4.52±0.50 and 3.18±0.34 ng mg−1creatinine, PRE and POST respectively). Training both in MOD and HIDT did not significantly modify plasma levels of PC. Resting plasma TAC was reduced in MOD while no significant changes were observed in HIDT. In conclusion, these results

  1. Moderate volume of high relative training intensity produces greater strength gains compared with low and high volumes in competitive weightlifters.

    PubMed

    González-Badillo, Juan José; Izquierdo, Mikel; Gorostiaga, Esteban M

    2006-02-01

    The purpose of this study was to examine the effect of 3 volumes of heavy resistance, average relative training intensity (expressed as a percentage of 1 repetition maximum that represented the absolute kilograms lifted divided by the number of repetitions performed) programs on maximal strength (1RM) in Snatch (Sn), Clean & Jerk (C&J), and Squat (Sq). Twenty-nine experienced (>3 years), trained junior weightlifters were randomly assigned into 1 of 3 groups: low-intensity group (LIG; n = 12), moderate-intensity group (MIG; n = 9), and high-intensity group (HIG; n = 8). All subjects trained for 10 weeks, 4-5 days a week, in a periodized routine using the same exercises and training volume (expressed as total number of repetitions performed at intensities equal to or greater than 60% of 1RM), but different programmed total repetitions at intensities of >90-100% of 1RM for the entire 10-week period: LIG (46 repetitions), MIG (93 repetitions), and HIG (184 repetitions). During the training period, MIG and LIG showed a significant increase (p < 0.01-0.05) for C&J (10.5% and 3% for MIG and LIG, respectively) and Sq (9.5% and 5.3% for MIG and LIG, respectively), whereas in HIG the increase took place only in Sq (6.9%, p < 0.05). A calculation of effect sizes revealed greater strength gains in the MIG than in HIG or LIG. There were no significant differences between LIG and HIG training volume-induced strength gains. All the subjects in HIG were unable to fully accomplish the repetitions programmed at relative intensities greater than 90% of 1RM. The present results indicate that short-term resistance training using moderate volumes of high relative intensity tended to produce higher enhancements in weightlifting performance compared with low and high volumes of high relative training intensities of equal total volume in experienced, trained young weightlifters. Therefore, for the present population of weightlifters, it may be beneficial to use the MIG training protocol to

  2. Lead paint removal with high-intensity light pulses.

    PubMed

    Grapperhaus, Michael J; Schaefer, Raymond B

    2006-12-15

    This paper presents the results of an initial investigation into using high-intensity incoherent light pulses to strip paint. Measurements of light pulse characteristics, the reflectivity of different paints and initial experiments on the threshold for paint removal, and paint removal are presented, along with an approximate model consistent with experimental results. Paint removal tests include lead paint, the reduction of lead levels to below levels required for lead abatement, as well as air and light emissions measurements that are within regulatory guidelines.

  3. Potential of dynamically harmonized Fourier transform ion cyclotron resonance cell for high-throughput metabolomics fingerprinting: control of data quality.

    PubMed

    Habchi, Baninia; Alves, Sandra; Jouan-Rimbaud Bouveresse, Delphine; Appenzeller, Brice; Paris, Alain; Rutledge, Douglas N; Rathahao-Paris, Estelle

    2018-01-01

    Due to the presence of pollutants in the environment and food, the assessment of human exposure is required. This necessitates high-throughput approaches enabling large-scale analysis and, as a consequence, the use of high-performance analytical instruments to obtain highly informative metabolomic profiles. In this study, direct introduction mass spectrometry (DIMS) was performed using a Fourier transform ion cyclotron resonance (FT-ICR) instrument equipped with a dynamically harmonized cell. Data quality was evaluated based on mass resolving power (RP), mass measurement accuracy, and ion intensity drifts from the repeated injections of quality control sample (QC) along the analytical process. The large DIMS data size entails the use of bioinformatic tools for the automatic selection of common ions found in all QC injections and for robustness assessment and correction of eventual technical drifts. RP values greater than 10 6 and mass measurement accuracy of lower than 1 ppm were obtained using broadband mode resulting in the detection of isotopic fine structure. Hence, a very accurate relative isotopic mass defect (RΔm) value was calculated. This reduces significantly the number of elemental composition (EC) candidates and greatly improves compound annotation. A very satisfactory estimate of repeatability of both peak intensity and mass measurement was demonstrated. Although, a non negligible ion intensity drift was observed for negative ion mode data, a normalization procedure was easily applied to correct this phenomenon. This study illustrates the performance and robustness of the dynamically harmonized FT-ICR cell to perform large-scale high-throughput metabolomic analyses in routine conditions. Graphical abstract Analytical performance of FT-ICR instrument equipped with a dynamically harmonized cell.

  4. Protection of Lotus Seedpod Proanthocyanidins on Organs and Tissues under High-intensity Excercise

    PubMed Central

    Mengyan, Zhang

    2015-01-01

    Lotus seedpod proanthocyanidins (LSPC) as a kind of polyphenols is widely used in medicines, cosmetics, health products. High-intensity exercise can cause damage to the body's organs and tissues. Different doses of LSPC is given to mice to check the function of protect effect to the body's organs and tissues under high-intensity exercise. The hemoglobin (HB) content, red blood cell (RBC) number and white blood cell (WBC) number were tested for mice after exercise. The activity of superoxide dismutase (SOD) and the contents of glutathione (GSH) and malondialdehyde (MDA) in muscle and viscera were evaluated. The result showed that LSPC can effectively reduce inflammation reaction in the body of mice with high intensity exercise, alleviate oxidative stress-induced injury of tissues and organs, and execute protective function on skeletal muscle and cardiac muscle. And the LSPC could enhance myocardial anti-oxygen and enzymatic activity which suggests the protective effects of resveratrol against exercise-induced myocardial damage in mice. PMID:26998176

  5. Creatine kinase response to high-intensity aerobic exercise in adult-onset muscular dystrophy.

    PubMed

    Andersen, Søren P; Sveen, Marie-Louise; Hansen, Regitze S; Madsen, Karen L; Hansen, Jonas B; Madsen, Mads; Vissing, John

    2013-12-01

    We investigated the effect of high-intensity exercise on plasma creatine kinase (CK) in patients with muscular dystrophies. Fourteen patients with Becker (BMD), facioscapulohumeral (FSHD), or limb-girdle type 2 (LGMD2) muscular dystrophy, and 8 healthy subjects performed 5 cycling tests: an incremental max test, and tests at 65%, 75%, 85%, and 95% of maximal oxygen uptake (VO2max ). Heart rate and oxygen consumption were measured during the tests, and plasma CK was measured before, immediately after, and 24 hours after exercise. All subjects were able to perform high-intensity exercise at the different levels. In patients with LGMD2 and FSHD, CK normalized 24 hours after exercise compared with the pre-exercise value, whereas those with BMD and healthy controls had elevated CK values 24 hours after exercise. The findings suggest that high-intensity exercise is generally well tolerated in patients with LGMD2 and FSHD, whereas those with BMD may be more prone to exercise-induced damage. Copyright © 2013 Wiley Periodicals, Inc.

  6. Achieving Guideline-Driven High-Intensity Statin Dose in Cardiac Rehabilitation Patients With Coronary Artery Disease.

    PubMed

    Lin, Jonathan; Banathy, Alexandra; Winters, Carla; Andersen, Lars; Hudson, Cindy; Testa, Heidi; Reardon, Joy; Alagona, Peter

    2018-05-12

    The 2013 American College of Cardiology/American Heart Association Guideline on the Treatment of Blood Cholesterol to Reduce Atherosclerotic Cardiovascular Risk in Adults recommends high-intensity statin therapy in patients aged ≤75 y with clinical coronary artery disease (CAD). The effectiveness of cardiac rehabilitation (CR) in lipid management and guideline adherence is unknown. The purpose of this study is to determine whether CR participation affects guideline-driven achievement for statin use. This multicenter retrospective study evaluated statin utilization in patients pre- and post-CR between January 1, 2014, and August 31, 2015. Records for patients with known CAD who completed 18 or more CR sessions were reviewed for statin-drug use and dose before and after CR and documented statin intolerance. Of the total 468 patients, 76% were male with mean age ± SD = 66.0 ± 10.8 y and range of 32 to 89 y. Patients aged ≤75 y (n = 375) showed a modest but statistically significant increase (P = .0006) in high-intensity statin use post-CR (56.3%-61.1%). Males demonstrated a significant increase in high-intensity statin use (P = .0005). Of the 146 patients aged ≤75 y not on high-intensity statins post-CR, only 21 had history of statin intolerance. Of the subjects aged >75 y (n = 93), 91% were already on high- or moderate-intensity statins with no significant change during CR. Patients aged ≤75 y following CR completion increased high-intensity statin use but only by 4.8% and 33% of subjects were inadequately treated. The updated 2013 treatment recommendations simplified statin use, yet substantial data continue to reveal that guideline achievement even post-CR remains limited.

  7. Discussion on the application of high additional value of high purity and high quality direct reduced iron

    NASA Astrophysics Data System (ADS)

    Yue, Chongfeng; Bai, Lu; Hong, Yicheng; Xu, Lijun

    2018-03-01

    The high purity and high quality direct reduced iron(DRI) products which were produced by high grade and high quality iron powder, with a high grade and low impurity characteristics. This article introduced the application of high purity and high quality DRI in the fields of amorphous base material, atomized iron powder, powder superalloy, high purity and ultra-low carbon special metallurgy products, precision casting, super alloy and various iron-based alloys. It provides a reference for the high added value utilization of DRI.

  8. The preparation of high quality alumina defective photonic crystals and their application of photoluminescence enhancement

    NASA Astrophysics Data System (ADS)

    An, Yu-Ying; Wang, Jian; Zhou, Wen-Ming; Jin, Hong-Xia; Li, Jian-Feng; Wang, Cheng-Wei

    2018-07-01

    The high quality anodic aluminum oxide (AAO) defective photonic crystals (DPCs) have been successfully prepared by using a modified periodic pulse anodization technique including an effective voltage compensating strategy. The test results confirmed that the AAO DPCs were with a perfect regular layered-structure and had a narrow defective photonic band gap (DPBG) with a high quality defective mode. When the rhodamine B (rhB) was absorbed onto the pore walls of the AAO DPCs, it was found that the DPBG blue edge and localized defective mode inside could significantly enhance the photoluminescence (PL) intensity of rhodamine B (rhB), while they were carefully regulated to match with the emission peak position of rhB respectively. Even more intriguing was that the localized defective peak in DPBG had more notable effect on rhB's photoluminescence, 3.1 times higher than that of the control samples under the same conditions. The corresponding mechanism for photoluminescence enhancement was also discussed in detail.

  9. Validation of the Amsterdam Dynamic Facial Expression Set--Bath Intensity Variations (ADFES-BIV): A Set of Videos Expressing Low, Intermediate, and High Intensity Emotions.

    PubMed

    Wingenbach, Tanja S H; Ashwin, Chris; Brosnan, Mark

    2016-01-01

    Most of the existing sets of facial expressions of emotion contain static photographs. While increasing demand for stimuli with enhanced ecological validity in facial emotion recognition research has led to the development of video stimuli, these typically involve full-blown (apex) expressions. However, variations of intensity in emotional facial expressions occur in real life social interactions, with low intensity expressions of emotions frequently occurring. The current study therefore developed and validated a set of video stimuli portraying three levels of intensity of emotional expressions, from low to high intensity. The videos were adapted from the Amsterdam Dynamic Facial Expression Set (ADFES) and termed the Bath Intensity Variations (ADFES-BIV). A healthy sample of 92 people recruited from the University of Bath community (41 male, 51 female) completed a facial emotion recognition task including expressions of 6 basic emotions (anger, happiness, disgust, fear, surprise, sadness) and 3 complex emotions (contempt, embarrassment, pride) that were expressed at three different intensities of expression and neutral. Accuracy scores (raw and unbiased (Hu) hit rates) were calculated, as well as response times. Accuracy rates above chance level of responding were found for all emotion categories, producing an overall raw hit rate of 69% for the ADFES-BIV. The three intensity levels were validated as distinct categories, with higher accuracies and faster responses to high intensity expressions than intermediate intensity expressions, which had higher accuracies and faster responses than low intensity expressions. To further validate the intensities, a second study with standardised display times was conducted replicating this pattern. The ADFES-BIV has greater ecological validity than many other emotion stimulus sets and allows for versatile applications in emotion research. It can be retrieved free of charge for research purposes from the corresponding author.

  10. Metabolic responses to high protein diet in Korean elite bodybuilders with high-intensity resistance exercise

    PubMed Central

    2011-01-01

    Background High protein diet has been known to cause metabolic acidosis, which is manifested by increased urinary excretion of nitrogen and calcium. Bodybuilders habitually consumed excessive dietary protein over the amounts recommended for them to promote muscle mass accretion. This study investigated the metabolic response to high protein consumption in the elite bodybuilders. Methods Eight elite Korean bodybuilders within the age from 18 to 25, mean age 21.5 ± 2.6. For data collection, anthropometry, blood and urinary analysis, and dietary assessment were conducted. Results They consumed large amounts of protein (4.3 ± 1.2 g/kg BW/day) and calories (5,621.7 ± 1,354.7 kcal/day), as well as more than the recommended amounts of vitamins and minerals, including potassium and calcium. Serum creatinine (1.3 ± 0.1 mg/dl) and potassium (5.9 ± 0.8 mmol/L), and urinary urea nitrogen (24.7 ± 9.5 mg/dl) and creatinine (2.3 ± 0.7 mg/dl) were observed to be higher than the normal reference ranges. Urinary calcium (0.3 ± 0.1 mg/dl), and phosphorus (1.3 ± 0.4 mg/dl) were on the border of upper limit of the reference range and the urine pH was in normal range. Conclusions Increased urinary excretion of urea nitrogen and creatinine might be due to the high rates of protein metabolism that follow high protein intake and muscle turnover. The obvious evidence of metabolic acidosis in response to high protein diet in the subjects with high potassium intake and intensive resistance exercise were not shown in this study results. However, this study implied that resistance exercise with adequate mineral supplementation, such as potassium and calcium, could reduce or offset the negative effects of protein-generated metabolic changes. This study provides preliminary information of metabolic response to high protein intake in bodybuilders who engaged in high-intensity resistance exercise. Further studies will be needed to determine the effects of the intensity of exercise and the

  11. Metabolic responses to high protein diet in Korean elite bodybuilders with high-intensity resistance exercise.

    PubMed

    Kim, Hyerang; Lee, Saningun; Choue, Ryowon

    2011-07-04

    High protein diet has been known to cause metabolic acidosis, which is manifested by increased urinary excretion of nitrogen and calcium. Bodybuilders habitually consumed excessive dietary protein over the amounts recommended for them to promote muscle mass accretion. This study investigated the metabolic response to high protein consumption in the elite bodybuilders. Eight elite Korean bodybuilders within the age from 18 to 25, mean age 21.5 ± 2.6. For data collection, anthropometry, blood and urinary analysis, and dietary assessment were conducted. They consumed large amounts of protein (4.3 ± 1.2 g/kg BW/day) and calories (5,621.7 ± 1,354.7 kcal/day), as well as more than the recommended amounts of vitamins and minerals, including potassium and calcium. Serum creatinine (1.3 ± 0.1 mg/dl) and potassium (5.9 ± 0.8 mmol/L), and urinary urea nitrogen (24.7 ± 9.5 mg/dl) and creatinine (2.3 ± 0.7 mg/dl) were observed to be higher than the normal reference ranges. Urinary calcium (0.3 ± 0.1 mg/dl), and phosphorus (1.3 ± 0.4 mg/dl) were on the border of upper limit of the reference range and the urine pH was in normal range. Increased urinary excretion of urea nitrogen and creatinine might be due to the high rates of protein metabolism that follow high protein intake and muscle turnover. The obvious evidence of metabolic acidosis in response to high protein diet in the subjects with high potassium intake and intensive resistance exercise were not shown in this study results. However, this study implied that resistance exercise with adequate mineral supplementation, such as potassium and calcium, could reduce or offset the negative effects of protein-generated metabolic changes. This study provides preliminary information of metabolic response to high protein intake in bodybuilders who engaged in high-intensity resistance exercise. Further studies will be needed to determine the effects of the intensity of exercise and the level of mineral intakes, especially

  12. Ultrasound-guided high-intensity focused ultrasound ablation for treating uterine arteriovenous malformation.

    PubMed

    Yan, X; Zhao, C; Tian, C; Wen, S; He, X; Zhou, Y

    2017-08-01

    To explore HIFU treatment for uterine arteriovenous malformation. A case report. Gynaecological department in a university teaching hospital of China. A patient with uterine arteriovenous malformation. The diagnosis of uterine arteriovenous malformation was made through MRI. Ultrasound-guided high-intensity focused ultrasound (USgHIFU) ablation was performed. HIFU is effective in treating uterine arteriovenous malformation. The patient had reduction of the lesion volume and obvious symptom relief, without significant adverse effects. HIFU can be used as a new treatment option for uterine arteriovenous malformation. Ultrasound-guided high-intensity focused ultrasound ablation is effective in treating uterine arteriovenous malformation. © 2017 Royal College of Obstetricians and Gynaecologists.

  13. Magnetic resonance guided high-intensity focused ultrasound ablation of musculoskeletal tumors

    PubMed Central

    Avedian, Raffi S.; Gold, Garry; Ghanouni, Pejman; Pauly, Kim Butts

    2015-01-01

    This article reviews the fundamental principles and clinical experimental uses of magnetic resonance guided high-intensity focused ultrasound (MRgHIFU) ablation of musculoskeletal tumors. MRgHIFU is a noninvasive treatment modality that takes advantage of the ability of magnetic resonance to measure tissue temperature and uses this technology to guide high-intensity focused ultrasound waves to a specific focus within the human body that results in heat generation and complete thermal necrosis of the targeted tissue. Adjacent normal tissues are spared because of the accurate delivery of thermal energy, as well as, local blood perfusion that provides a cooling effect. MRgHIFU is approved by the Food and Drug Administration for the treatment of uterine fibroids and is used on an experimental basis to treat breast, prostate, liver, bone, and brain tumors. PMID:26120376

  14. Infrastructure for quality transformation: measurement and reporting in veterans administration intensive care units.

    PubMed

    Render, Marta L; Freyberg, Ron W; Hasselbeck, Rachael; Hofer, Timothy P; Sales, Anne E; Deddens, James; Levesque, Odette; Almenoff, Peter L

    2011-06-01

    BACKGROUND Veterans Health Administration (VA) intensive care units (ICUs) develop an infrastructure for quality improvement using information technology and recruiting leadership. METHODS Setting Participation by the 183 ICUs in the quality improvement program is required. Infrastructure includes measurement (electronic data extraction, analysis), quarterly web-based reporting and implementation support of evidence-based practices. Leaders prioritise measures based on quality improvement objectives. The electronic extraction is validated manually against the medical record, selecting hospitals whose data elements and measures fall at the extremes (10th, 90th percentile). results are depicted in graphic, narrative and tabular reports benchmarked by type and complexity of ICU. RESULTS The VA admits 103 689±1156 ICU patients/year. Variation in electronic business practices, data location and normal range of some laboratory tests affects data quality. A data management website captures data elements important to ICU performance and not available electronically. A dashboard manages the data overload (quarterly reports ranged 106-299 pages). More than 85% of ICU directors and nurse managers review their reports. Leadership interest is sustained by including ICU targets in executive performance contracts, identification of local improvement opportunities with analytic software, and focused reviews. CONCLUSION Lessons relevant to non-VA institutions include the: (1) need for ongoing data validation, (2) essential involvement of leadership at multiple levels, (3) supplementation of electronic data when key elements are absent, (4) utility of a good but not perfect electronic indicator to move practice while improving data elements and (5) value of a dashboard.

  15. Impact of high-intensity concurrent training on cardiovascular risk factors in persons with multiple sclerosis - pilot study.

    PubMed

    Keytsman, Charly; Hansen, Dominique; Wens, Inez; O Eijnde, Bert

    2017-10-27

    High-intensity concurrent training positively affects cardiovascular risk factors. Because this was never investigated in multiple sclerosis, the present pilot study explored the impact of this training on cardiovascular risk factors in this population. Before and after 12 weeks of high-intense concurrent training (interval and strength training, 5 sessions per 2 weeks, n = 16) body composition, resting blood pressure and heart rate, 2-h oral glucose tolerance (insulin sensitivity, glycosylated hemoglobin, blood glucose and insulin concentrations), blood lipids (high- and low-density lipoprotein, total cholesterol, triglyceride levels) and C-reactive protein were analyzed. Twelve weeks of high-intense concurrent training significantly improved resting heart rate (-6%), 2-h blood glucose concentrations (-13%) and insulin sensitivity (-24%). Blood pressure, body composition, blood lipids and C-reactive protein did not seem to be affected. Under the conditions of this pilot study, 12 weeks of concurrent high-intense interval and strength training improved resting heart rate, 2-h glucose and insulin sensitivity in multiple sclerosis but did not affect blood C-reactive protein levels, blood pressure, body composition and blood lipid profiles. Further, larger and controlled research investigating the effects of high-intense concurrent training on cardiovascular risk factors in multiple sclerosis is warranted. Implications for rehabilitation High-intensity concurrent training improves cardiovascular fitness. This pilot study explores the impact of this training on cardiovascular risk factors in multiple sclerosis. Despite the lack of a control group, high-intense concurrent training does not seem to improve cardiovascular risk factors in multiple sclerosis.

  16. Cardiorespiratory fitness modulates the acute flow-mediated dilation response following high-intensity but not moderate-intensity exercise in elderly men.

    PubMed

    Bailey, Tom G; Perissiou, Maria; Windsor, Mark; Russell, Fraser; Golledge, Jonathan; Green, Daniel J; Askew, Christopher D

    2017-05-01

    Impaired endothelial function is observed with aging and in those with low cardiorespiratory fitness (V̇o 2peak ). Improvements in endothelial function with exercise training are somewhat dependent on the intensity of exercise. While the acute stimulus for this improvement is not completely understood, it may, in part, be due to the flow-mediated dilation (FMD) response to acute exercise. We examined the hypothesis that exercise intensity alters the brachial (systemic) FMD response in elderly men and is modulated by V̇o 2peak Forty-seven elderly men were stratified into lower (V̇o 2peak = 24.3 ± 2.9 ml·kg -1 ·min -1 ; n = 27) and higher fit groups (V̇o 2peak = 35.4 ± 5.5 ml·kg -1 ·min -1 ; n = 20) after a test of cycling peak power output (PPO). In randomized order, participants undertook moderate-intensity continuous exercise (MICE; 40% PPO) or high-intensity interval cycling exercise (HIIE; 70% PPO) or no-exercise control. Brachial FMD was assessed at rest and 10 and 60 min after exercise. FMD increased after MICE in both groups {increase of 0.86% [95% confidence interval (CI), 0.17-1.56], P = 0.01} and normalized after 60 min. In the lower fit group, FMD was reduced after HIIE [reduction of 0.85% (95% CI, 0.12-1.58), P = 0.02] and remained decreased at 60 min. In the higher fit group, FMD was unchanged immediately after HIIE and increased after 60 min [increase of 1.52% (95% CI, 0.41-2.62), P < 0.01, which was correlated with V̇o 2peak , r = 0.41; P < 0.01]. In the no-exercise control, FMD was reduced in both groups after 60 min ( P = 0.05). Exercise intensity alters the acute FMD response in elderly men and V̇o 2peak modulates the FMD response following HIIE but not MICE. The sustained decrease in FMD in the lower fit group following HIIE may represent a signal for vascular adaptation or endothelial fatigue. NEW & NOTEWORTHY This study is the first to show that moderate-intensity continuous cycling exercise increased flow-mediated dilation (FMD

  17. Effect of High-Intensity Wildfire and Silvicultural Treatments on Reptile Communities in Sand-Pine Scrub

    Treesearch

    Cathryn H. Greenberg; Daniel G. Neary; Larry D. Harris

    1994-01-01

    We tested whether the herpetofuunal response to clearcutting followed by site preparation was similar to high-intensity wildfire foIlowed by salvage logging in sand- pine scrub. Herpetofaunal communities were compared in three replicated 5- to 7-yearpost-disturbance treatments and mature sand-pine forest. The three disturbance treatments were (1) high-intensity...

  18. Highly Integrated Quality Assurance – An Empirical Case

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drake Kirkham; Amy Powell; Lucas Rich

    2011-02-01

    Highly Integrated Quality Assurance – An Empirical Case Drake Kirkham1, Amy Powell2, Lucas Rich3 1Quality Manager, Radioisotope Power Systems (RPS) Program, Idaho National Laboratory, P.O. Box 1625 M/S 6122, Idaho Falls, ID 83415-6122 2Quality Engineer, RPS Program, Idaho National Laboratory 3Quality Engineer, RPS Program, Idaho National Laboratory Contact: Voice: (208) 533-7550 Email: Drake.Kirkham@inl.gov Abstract. The Radioisotope Power Systems Program of the Idaho National Laboratory makes an empirical case for a highly integrated Quality Assurance function pertaining to the preparation, assembly, testing, storage and transportation of 238Pu fueled radioisotope thermoelectric generators. Case data represents multiple campaigns including the Pluto/New Horizons mission,more » the Mars Science Laboratory mission in progress, and other related projects. Traditional Quality Assurance models would attempt to reduce cost by minimizing the role of dedicated Quality Assurance personnel in favor of either functional tasking or peer-based implementations. Highly integrated Quality Assurance adds value by placing trained quality inspectors on the production floor side-by-side with nuclear facility operators to enhance team dynamics, reduce inspection wait time, and provide for immediate, independent feedback. Value is also added by maintaining dedicated Quality Engineers to provide for rapid identification and resolution of corrective action, enhanced and expedited supply chain interfaces, improved bonded storage capabilities, and technical resources for requirements management including data package development and Certificates of Inspection. A broad examination of cost-benefit indicates highly integrated Quality Assurance can reduce cost through the mitigation of risk and reducing administrative burden thereby allowing engineers to be engineers, nuclear operators to be nuclear operators, and the cross-functional team to operate more efficiently. Applicability of this

  19. Numerical simulation of laser ion acceleration at ultra high intensity

    NASA Astrophysics Data System (ADS)

    Tatomirescu, Dragos; Popescu, Alexandra; d'Humières, Emmanuel; Vizman, Daniel

    2017-01-01

    With the latest advances in attainable laser intensity, the need to obtain better quality ion and electron beams has been a major field of research. This paper studies the effects of different target density profiles on the spatial distribution of the accelerated particles, the maximum energies achieved, and the characteristics of the electromagnetic fields using the same laser pulse parameters. The study starts by describing a baseline for a flat target which presents a proton-rich microdot on its backside. The effects of introducing a target curvature and, further on, a cone laser focusing structure are compared with the flat target baseline results. The maximum energy obtained increases when using complex structures, and also a smaller divergence of the ion beam is observed.

  20. High-resolution stochastic generation of extreme rainfall intensity for urban drainage modelling applications

    NASA Astrophysics Data System (ADS)

    Peleg, Nadav; Blumensaat, Frank; Molnar, Peter; Fatichi, Simone; Burlando, Paolo

    2016-04-01

    Urban drainage response is highly dependent on the spatial and temporal structure of rainfall. Therefore, measuring and simulating rainfall at a high spatial and temporal resolution is a fundamental step to fully assess urban drainage system reliability and related uncertainties. This is even more relevant when considering extreme rainfall events. However, the current space-time rainfall models have limitations in capturing extreme rainfall intensity statistics for short durations. Here, we use the STREAP (Space-Time Realizations of Areal Precipitation) model, which is a novel stochastic rainfall generator for simulating high-resolution rainfall fields that preserve the spatio-temporal structure of rainfall and its statistical characteristics. The model enables a generation of rain fields at 102 m and minute scales in a fast and computer-efficient way matching the requirements for hydrological analysis of urban drainage systems. The STREAP model was applied successfully in the past to generate high-resolution extreme rainfall intensities over a small domain. A sub-catchment in the city of Luzern (Switzerland) was chosen as a case study to: (i) evaluate the ability of STREAP to disaggregate extreme rainfall intensities for urban drainage applications; (ii) assessing the role of stochastic climate variability of rainfall in flow response and (iii) evaluate the degree of non-linearity between extreme rainfall intensity and system response (i.e. flow) for a small urban catchment. The channel flow at the catchment outlet is simulated by means of a calibrated hydrodynamic sewer model.

  1. Improvement in clinical outcomes after dry needling versus myofascial release on pain pressure thresholds, quality of life, fatigue, pain intensity, quality of sleep, anxiety, and depression in patients with fibromyalgia syndrome.

    PubMed

    Castro Sánchez, Adelaida M; García López, Hector; Fernández Sánchez, Manuel; Pérez Mármol, José Manuel; Aguilar-Ferrándiz, María Encarnación; Luque Suárez, Alejandro; Matarán Peñarrocha, Guillermo Adolfo

    2018-04-23

    To compare the effectiveness of dry needling versus myofascial release on myofascial trigger points pain in cervical muscles, quality of life, impact of symptoms pain, quality of sleep, anxiety, depression, and fatigue in patients with fibromyalgia syndrome. A single-blind randomized controlled trial was conducted. Sixty-four subjects with fibromyalgia were randomly assigned to a dry needling group or a myofascial release group. Pain pressure thresholds of myofascial trigger points were evaluated in the cervical muscles. In addition, quality of life, impact of fibromyalgia symptoms, quality of sleep, intensity of pain, anxiety and depression symptoms, impact of fatigue at baseline and post treatment after four weeks of intervention were evaluated. Significant improvement was found in most pain pressure thresholds of the myofascial trigger points in cervical muscles in the dry needling group compared to myofascial release (p < 0.05). Similarly, these differences between groups were found for the components of quality of life of physical function (F = 12.74, p = 0.001), physical role (F = 11.24, p = 0.001), body pain (F =30.26, p < 0.001), general health (F = 15.83, p < 0.001), vitality (F = 13.51, p = 0.001), social function (F = 4.73, p = 0.034), emotional role (F = 8.01, p = 0.006), and mental health (F = 4.95, p = 0.030). Similar results were achieved for total impact of FMS symptoms (F = 42.91, p < 0.001), quality of sleep (F = 11.96, p = 0.001), state anxiety (F = 7.40, p = 0.009), and trait anxiety (F = -14.63, p < 0.001), hospital anxiety and depression (F = 20.60, p < 0.001), general pain intensity (F = 29.59, p < 0.001), and fatigue (F = -25.73, p < 0.001). The dry needling therapy showed higher improvements in comparison with myofascial release therapy for pain pressure thresholds, the components of quality of life of physical role

  2. High-quality graphene flakes exfoliated on a flat hydrophobic polymer

    NASA Astrophysics Data System (ADS)

    Pedrinazzi, Paolo; Caridad, José M.; Mackenzie, David M. A.; Pizzocchero, Filippo; Gammelgaard, Lene; Jessen, Bjarke S.; Sordan, Roman; Booth, Timothy J.; Bøggild, Peter

    2018-01-01

    We show that graphene supported on a hydrophobic and flat polymer surface results in flakes with extremely low doping and strain as assessed by their Raman spectroscopic characteristics. We exemplify this technique by micromechanical exfoliation of graphene on flat poly(methylmethacrylate) layers and demonstrate Raman peak intensity ratios I(2D)/I(G) approaching 10, similar to pristine freestanding graphene. We verify that these features are not an artifact of optical interference effects occurring at the substrate: they are similarly observed when varying the substrate thickness and are maintained when the environment of the graphene flake is completely changed, by encapsulating preselected flakes between hexagonal boron nitride layers. The exfoliation of clean, pristine graphene layers directly on flat polymer substrates enables high performance, supported, and non-encapsulated graphene devices for flexible and transparent optoelectronic studies. We additionally show that the access to a clean and supported graphene source leads to high-quality van der Waals heterostructures and devices with reproducible carrier mobilities exceeding 50 000 cm2 V-1 s-1 at room temperature.

  3. Perspectives on high-intensity interval exercise for health promotion in children and adolescents

    PubMed Central

    Bond, Bert; Weston, Kathryn L; Williams, Craig A; Barker, Alan R

    2017-01-01

    Physical activity lowers future cardiovascular disease (CVD) risk; however, few children and adolescents achieve the recommended minimum amount of daily activity. Accordingly, there is virtue in identifying the efficacy of small volumes of high-intensity exercise for health benefits in children and adolescents for the primary prevention of CVD risk. The purpose of this narrative review is to provide a novel overview of the available literature concerning high-intensity interval-exercise (HIIE) interventions in children and adolescents. Specifically, the following areas are addressed: 1) outlining the health benefits observed following a single bout of HIIE, 2) reviewing the role of HIIE training in the management of pediatric obesity, and 3) discussing the effectiveness of school-based HIIE training. In total, 39 HIIE intervention studies were included in this review. Based upon the available data, a single bout of high-intensity exercise provides a potent stimulus for favorable, acute changes across a range of cardiometabolic outcomes that are often superior to a comparative bout of moderate-intensity exercise (14 studies reviewed). HIIE also promotes improvements in cardiorespiratory fitness and cardiometabolic health status in overweight and obese children and adolescents (10 studies reviewed) and when delivered in the school setting (15 studies reviewed). We thus conclude that high-intensity exercise is a feasible and potent method of improving a range of cardiometabolic outcomes in children and adolescents. However, further work is needed to optimize the delivery of HIIE interventions in terms of participant enjoyment and acceptability, to include a wider range of health outcomes, and to control for important confounding variables (eg, changes in diet and habitual physical activity). Finally, research into the application of HIIE training interventions to children and adolescents of different ages, sexes, pubertal status, and sociocultural backgrounds is

  4. [Cross sectional study of structural quality of German intensive care units. A reevaluation of the DIVI register].

    PubMed

    Fölsch, C; Kofahl, N; Waydhas, C; Stiletto, R

    2013-09-01

    periods or between hospitals with different structures. Overall availability of medical staff and diagnostic procedures increased during the study period. An increase of availability of fully trained medical staff in intensive care medicine is desirable to increase the quality of treatment.

  5. Correction of aeroheating-induced intensity nonuniformity in infrared images

    NASA Astrophysics Data System (ADS)

    Liu, Li; Yan, Luxin; Zhao, Hui; Dai, Xiaobing; Zhang, Tianxu

    2016-05-01

    Aeroheating-induced intensity nonuniformity effects severely influence the effective performance of an infrared (IR) imaging system in high-speed flight. In this paper, we propose a new approach to the correction of intensity nonuniformity in IR images. The basic assumption is that the low-frequency intensity bias is additive and smoothly varying so that it can be modeled as a bivariate polynomial and estimated by using an isotropic total variation (TV) model. A half quadratic penalty method is applied to the isotropic form of TV discretization. And an alternating minimization algorithm is adopted for solving the optimization model. The experimental results of simulated and real aerothermal images show that the proposed correction method can effectively improve IR image quality.

  6. The Benefits of High Intensity Functional Training (HIFT) Fitness Programs for Military Personnel

    PubMed Central

    Haddock, Christopher K.; Poston, Walker S.C.; Heinrich, Katie M.; Jahnke, Sara A.; Jitnarin, Nattinee

    2016-01-01

    High intensity functional training (HIFT) programs are designed to address multiple fitness domains, potentially providing improved physical and mental readiness in a changing operational environment. Programs consistent with HIFT principals such as CrossFit, SEALFIT and the US Marine Corps’ High Intensity Tactical Training (HITT) program are increasingly popular among military personnel. This article reviews the practical, health, body composition, and military fitness implications of HIFT exercise programs. We conclude that, given the unique benefits of HIFT, the military should consider evaluating whether these programs should be the standard for military fitness training. PMID:27849484

  7. High-frequency and high-quality silicon carbide optomechanical microresonators

    PubMed Central

    Lu, Xiyuan; Lee, Jonathan Y.; Lin, Qiang

    2015-01-01

    Silicon carbide (SiC) exhibits excellent material properties attractive for broad applications. We demonstrate the first SiC optomechanical microresonators that integrate high mechanical frequency, high mechanical quality, and high optical quality into a single device. The radial-breathing mechanical mode has a mechanical frequency up to 1.69 GHz with a mechanical Q around 5500 in atmosphere, which corresponds to a fm · Qm product as high as 9.47 × 1012 Hz. The strong optomechanical coupling allows us to efficiently excite and probe the coherent mechanical oscillation by optical waves. The demonstrated devices, in combination with the superior thermal property, chemical inertness, and defect characteristics of SiC, show great potential for applications in metrology, sensing, and quantum photonics, particularly in harsh environments that are challenging for other device platforms. PMID:26585637

  8. Novel, high-intensity exercise prescription improves muscle mass, mitochondrial function, and physical capacity in individuals with Parkinson's disease

    PubMed Central

    Kelly, Neil A.; Ford, Matthew P.; Standaert, David G.; Watts, Ray L.; Bickel, C. Scott; Moellering, Douglas R.; Tuggle, S. Craig; Williams, Jeri Y.; Lieb, Laura; Windham, Samuel T.

    2014-01-01

    We conducted, in persons with Parkinson's disease (PD), a thorough assessment of neuromotor function and performance in conjunction with phenotypic analyses of skeletal muscle tissue, and further tested the adaptability of PD muscle to high-intensity exercise training. Fifteen participants with PD (Hoehn and Yahr stage 2–3) completed 16 wk of high-intensity exercise training designed to simultaneously challenge strength, power, endurance, balance, and mobility function. Skeletal muscle adaptations (P < 0.05) to exercise training in PD included myofiber hypertrophy (type I: +14%, type II: +36%), shift to less fatigable myofiber type profile, and increased mitochondrial complex activity in both subsarcolemmal and intermyofibrillar fractions (I: +45–56%, IV: +39–54%). These adaptations were accompanied by a host of functional and clinical improvements (P < 0.05): total body strength (+30–56%); leg power (+42%); single leg balance (+34%); sit-to-stand motor unit activation requirement (−30%); 6-min walk (+43 m), Parkinson's Disease Quality of Life Scale (PDQ-39, −7.8pts); Unified Parkinson's Disease Rating Scale (UPDRS) total (−5.7 pts) and motor (−2.7 pts); and fatigue severity (−17%). Additionally, PD subjects in the pretraining state were compared with a group of matched, non-PD controls (CON; did not exercise). A combined assessment of muscle tissue phenotype and neuromuscular function revealed a higher distribution and larger cross-sectional area of type I myofibers and greater type II myofiber size heterogeneity in PD vs. CON (P < 0.05). In conclusion, persons with moderately advanced PD adapt to high-intensity exercise training with favorable changes in skeletal muscle at the cellular and subcellular levels that are associated with improvements in motor function, physical capacity, and fatigue perception. PMID:24408997

  9. Follow-up after four-year quality improvement program to prevent inferior limb deep vein thrombosis in intensive care unit.

    PubMed

    Boddi, Maria; Cecchi, Andrea; Bonizzoli, Manuela; Barbani, Francesco; Franci, Andrea; Anichini, Valentina; Batacchi, Stefano; Parodo, Jessyca; Gensini, Gian Franco; Peris, Adriano

    2014-09-01

    Deep vein thrombosis (DVT) is a life-threatening complication in intensive care unit (ICU) patients and DVT incidence is used as a marker of quality care. In our ICU an educational program for implementation of DVT prophylaxis and ultrasound screening resulted in a remarkable decrease in DVT incidence which fell from 11.6% to 4.7%. The aim of this paper is to investigate a 4-year long persistent quality improvement of DVT prophylaxis obtained through the implementation of our educational intervention. The study was composed of three phases: after the first retrospective investigation of DVT incidence and the evidence of the efficacy of the educational program, this third phase investigates the 2-year long sustainability and persistence in the fall of DVT incidence by the adoption of 1) an electronic form for DVT prophylaxis prescription, 2) a nursing protocol for the application of elastic stokes and 3) a personalized form with a check-list dedicated to DVT prophylaxis. Ultrasound DVT screening was performed twice a week by ICU clinicians. The application of DVT prophylaxis was associated with a very low incidence of DVT (2.6%) not entirely attributable to changes in characteristics of enrolled patients and/or to less intensive DVT ultrasound screening when compared to the preceding phases. Mean mechanical ventilation duration and ICU length of stay were short and similar to those of the second phase and ICU mortality did not change. The direct involvement of ICU clinicians and nurses in the application of DVT prophylaxis and in DVT diagnosis markedly contributed to maintain a low DVT incidence over time, despite the high turnover of patients. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Effect Of Molecular Rotations On High Intensity Absorption In CO2

    NASA Astrophysics Data System (ADS)

    Bandrauk, Andre D.; Claveau, Lorraine

    1986-10-01

    In intense fields, the Rabi frequency ωR = pE/h can easily be of the order of rotational and vibrational energies of molecules. This means that rotations as well as vibrations become strongly perturbed so that perturbative methods no longer apply. We will show that nonperturbative methods can be derived from the concept of the dressed molecule. This leads to coupled equations which are used ko simulate numerically the multiphoton processes which will occur at intensities > 108 W/cm2. Furthermore, for multiphoton rotational tran-sitions, one can derive analytical models which help one understand the temporal behaviour of energy flow in a molecule in terms of its dressed spectrum, such as chaotic or regular (nonchaotic) behaviour. These results are of relevance to the manifestation of multiphoton coherences in a CO2 spectrum at very high intensities (I % 1012 W/cm2).

  11. Identification of patient information corruption in the intensive care unit: using a scoring tool to direct quality improvements in handover.

    PubMed

    Pickering, Brian W; Hurley, Killian; Marsh, Brian

    2009-11-01

    To use a handover assessment tool for identifying patient information corruption and objectively evaluating interventions designed to reduce handover errors and improve medical decision making. The continuous monitoring, intervention, and evaluation of the patient in modern intensive care unit practice generates large quantities of information, the platform on which medical decisions are made. Information corruption, defined as errors of distortion/omission compared with the medical record, may result in medical judgment errors. Identifying these errors may lead to quality improvements in intensive care unit care delivery and safety. Handover assessment instrument development study divided into two phases by the introduction of a handover intervention. Closed, 17-bed, university-affiliated mixed surgical/medical intensive care unit. Senior and junior medical members of the intensive care unit team. Electronic handover page. Study subjects were asked to recall clinical information commonly discussed at handover on individual patients. The handover score measured the percentage of information correctly retained for each individual doctor-patient interaction. The clinical intention score, a subjective measure of medical judgment, was graded (1-5) by three blinded intensive care unit experts. A total of 137 interactions were scored. Median (interquartile range) handover scores for phases 1 and 2 were 79.07% (67.44-84.50) and 83.72% (76.16-88.37), respectively. Score variance was reduced by the handover intervention (p < .05). Increasing median handover scores, 68.60 to 83.72, were associated with increases in clinical intention scores from 1 to 5 (chi-square = 23.59, df = 4, p < .0001). When asked to recall clinical information discussed at handover, medical members of the intensive care unit team provide data that are significantly corrupted compared with the medical record. Low subjective clinical judgment scores are significant associated with low handover scores

  12. Postexercise cold-water immersion improves intermittent high-intensity exercise performance in normothermia.

    PubMed

    McCarthy, Avina; Mulligan, James; Egaña, Mikel

    2016-11-01

    A brief cold water immersion between 2 continuous high-intensity exercise bouts improves the performance of the latter compared with passive recovery in the heat. We investigated if this effect is apparent in normothermic conditions (∼19 °C), employing an intermittent high-intensity exercise designed to reflect the work performed at the high-intensity domain in team sports. Fifteen young active men completed 2 exhaustive cycling protocols (Ex1 and Ex2: 12 min at 85% ventilatory threshold (VT) and then an intermittent exercise alternating 30-s at 40% peak power (P peak ) and 30 s at 90% P peak to exhaustion) separated by 15 min of (i) passive rest, (ii) 5-min cold-water immersion at 8 °C, and (iii) 10-min cold-water immersion at 8 °C. Core temperature, heart rate, rates of perceived exertion, and oxygen uptake kinetics were not different during Ex1 among conditions. Time to failure during the intermittent exercise was significantly (P < 0.05) longer during Ex2 following the 5- and 10-min cold-water immersions (7.2 ± 3.5 min and 7.3 ± 3.3 min, respectively) compared with passive rest (5.8 ± 3.1 min). Core temperature, heart rate, and rates of perceived exertion were significantly (P < 0.05) lower during most periods of Ex2 after both cold-water immersions compared with passive rest. The time constant of phase II oxygen uptake response during the 85% VT bout of Ex2 was not different among the 3 conditions. A postexercise, 5- to 10-min cold-water immersion increases subsequent intermittent high-intensity exercise compared with passive rest in normothermia due, at least in part, to reductions in core temperature, circulatory strain, and effort perception.

  13. High-intensity cycle interval training improves cycling and running performance in triathletes.

    PubMed

    Etxebarria, Naroa; Anson, Judith M; Pyne, David B; Ferguson, Richard A

    2014-01-01

    Effective cycle training for triathlon is a challenge for coaches. We compared the effects of two variants of cycle high-intensity interval training (HIT) on triathlon-specific cycling and running. Fourteen moderately-trained male triathletes ([Formula: see text]O2peak 58.7 ± 8.1 mL kg(-1) min(-1); mean ± SD) completed on separate occasions a maximal incremental test ([Formula: see text]O2peak and maximal aerobic power), 16 × 20 s cycle sprints and a 1-h triathlon-specific cycle followed immediately by a 5 km run time trial. Participants were then pair-matched and assigned randomly to either a long high-intensity interval training (LONG) (6-8 × 5 min efforts) or short high-intensity interval training (SHORT) (9-11 × 10, 20 and 40 s efforts) HIT cycle training intervention. Six training sessions were completed over 3 weeks before participants repeated the baseline testing. Both groups had an ∼7% increase in [Formula: see text]O2peak (SHORT 7.3%, ±4.6%; mean, ±90% confidence limits; LONG 7.5%, ±1.7%). There was a moderate improvement in mean power for both the SHORT (10.3%, ±4.4%) and LONG (10.7%, ±6.8%) groups during the last eight 20-s sprints. There was a small to moderate decrease in heart rate, blood lactate and perceived exertion in both groups during the 1-h triathlon-specific cycling but only the LONG group had a substantial decrease in the subsequent 5-km run time (64, ±59 s). Moderately-trained triathletes should use both short and long high-intensity intervals to improve cycling physiology and performance. Longer 5-min intervals on the bike are more likely to benefit 5 km running performance.

  14. Increasing reliability of APACHE II scores in a medical-surgical intensive care unit: a quality improvement study.

    PubMed

    Donahoe, Laura; McDonald, Ellen; Kho, Michelle E; Maclennan, Margaret; Stratford, Paul W; Cook, Deborah J

    2009-01-01

    Given their clinical, research, and administrative purposes, scores on the Acute Physiology and Chronic Health Evaluation (APACHE) II should be reliable, whether calculated by health care personnel or a clinical information system. To determine reliability of APACHE II scores calculated by a clinical information system and by health care personnel before and after a multifaceted quality improvement intervention. APACHE II scores of 37 consecutive patients admitted to a closed, 15-bed, university-affiliated intensive care unit were collected by a research coordinator, a database clerk, and a clinical information system. After a quality improvement intervention focused on health care personnel and the clinical information system, the same methods were used to collect data on 32 consecutive patients. The research coordinator and the clerk did not know each other's scores or the information system's score. The data analyst did not know the source of the scores until analysis was complete. APACHE II scores obtained by the clerk and the research coordinator were highly reliable (intraclass correlation coefficient, 0.88 before vs 0.80 after intervention; P = .25). No significant changes were detected after the intervention; however, compared with scores of the research coordinator, the overall reliability of APACHE II scores calculated by the clinical information system improved (intraclass correlation coefficient, 0.24 before intervention vs 0.91 after intervention, P < .001). After completion of a quality improvement intervention, health care personnel and a computerized clinical information system calculated sufficiently reliable APACHE II scores for clinical, research, and administrative purposes.

  15. Target Surface Area Effects on Hot Electron Dynamics from High Intensity Laser-Plasma Interactions

    DTIC Science & Technology

    2016-08-19

    New J. Phys. 18 (2016) 063020 doi:10.1088/1367-2630/18/6/063020 PAPER Target surface area effects on hot electron dynamics from high intensity laser ...Science, University ofMichigan, AnnArbor,MI 48109-2099, USA E-mail: czulick@umich.edu Keywords: laser -plasma,mass-limited, fast electrons, sheath...field Abstract Reduced surface area targets were studied using an ultra-high intensity femtosecond laser in order to determine the effect of electron

  16. Within-session responses to high-intensity interval training in spinal cord injury.

    PubMed

    Astorino, Todd Anthony; Thum, Jacob S

    2018-02-01

    Completion of high-intensity interval training (HIIT) increases maximal oxygen uptake and health status, yet its feasibility in persons with spinal cord injury is unknown. To compare changes in cardiorespiratory and metabolic variables between two interval training regimes and moderate intensity exercise. Nine adults with spinal cord injury (duration = 6.8 ± 6.2 year) initially underwent determination of peak oxygen uptake. During subsequent sessions, they completed moderate intensity exercise, HIIT, or sprint interval training. Oxygen uptake, heart rate, and blood lactate concentration were measured. Oxygen uptake and heart rate increased (p < 0.05) during both interval training sessions and were similar (p > 0.05) to moderate intensity exercise. Peak oxygen uptake and heart rate were higher (p < 0.05) with HIIT (90% peak oxygen uptake and 99% peak heart rate) and sprint interval training (80% peak oxygen uptake and 96% peak heart rate) versus moderate intensity exercise. Despite a higher intensity and peak cardiorespiratory strain, all participants preferred interval training versus moderate exercise. Examining long-term efficacy and feasibility of interval training in this population is merited, considering that exercise intensity is recognized as the most important variable factor of exercise programming to optimize maximal oxygen uptake. Implications for Rehabilitation Spinal cord injury (SCI) reduces locomotion which impairs voluntary physical activity, typically resulting in a reduction in peak oxygen uptake and enhanced chronic disease risk. In various able-bodied populations, completion of high-intensity interval training (HIIT) has been consistently reported to improve cardiorespiratory fitness and other health-related outcomes, although its efficacy in persons with SCI is poorly understood. Data from this study in 9 men and women with SCI show similar changes in oxygen uptake and heart in response to HIIT compared to a prolonged

  17. 7 CFR 29.1006 - Color intensity.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Color intensity. 29.1006 Section 29.1006 Agriculture... Type 92) § 29.1006 Color intensity. The varying degree of saturation or chroma. Color intensity as applied to tobacco describes the strength or weakness of a specific color or hue. (See Elements of Quality...

  18. 7 CFR 29.1006 - Color intensity.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Color intensity. 29.1006 Section 29.1006 Agriculture... Type 92) § 29.1006 Color intensity. The varying degree of saturation or chroma. Color intensity as applied to tobacco describes the strength or weakness of a specific color or hue. (See Elements of Quality...

  19. 7 CFR 29.1006 - Color intensity.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Color intensity. 29.1006 Section 29.1006 Agriculture... Type 92) § 29.1006 Color intensity. The varying degree of saturation or chroma. Color intensity as applied to tobacco describes the strength or weakness of a specific color or hue. (See Elements of Quality...

  20. 7 CFR 29.1006 - Color intensity.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Color intensity. 29.1006 Section 29.1006 Agriculture... Type 92) § 29.1006 Color intensity. The varying degree of saturation or chroma. Color intensity as applied to tobacco describes the strength or weakness of a specific color or hue. (See Elements of Quality...

  1. 7 CFR 29.1006 - Color intensity.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Color intensity. 29.1006 Section 29.1006 Agriculture... Type 92) § 29.1006 Color intensity. The varying degree of saturation or chroma. Color intensity as applied to tobacco describes the strength or weakness of a specific color or hue. (See Elements of Quality...

  2. [Highly quality-controlled radiation therapy].

    PubMed

    Shirato, Hiroki

    2005-04-01

    Advanced radiation therapy for intracranial disease has focused on set-up accuracy for the past 15 years. However, quality control in the prescribed dose is actually as important as the tumor set-up in radiation therapy. Because of the complexity of the three-dimensional radiation treatment planning system in recent years, the highly quality-controlled prescription of the dose has now been reappraised as the mainstream to improve the treatment outcome of radiation therapy for intracranial disease. The Japanese Committee for Quality Control of Radiation Therapy has developed fundamental requirements such as a QC committee in each hospital, a medical physicist, dosimetrists (QC members), and an external audit.

  3. Impact of High-intensity Intermittent and Moderate-intensity Continuous Exercise on Autonomic Modulation in Young Men.

    PubMed

    Cabral-Santos, C; Giacon, T R; Campos, E Z; Gerosa-Neto, J; Rodrigues, B; Vanderlei, L C M; Lira, F S

    2016-06-01

    The aim of this study was to compare heart rate variability (HRV) recovery after two iso-volume (5 km) exercises performed at different intensities. 14 subjects volunteered (25.17±5.08 years; 74.7±6.28 kg; 175±0.05 cm; 59.56±5.15 mL·kg(-1)·min(-1)) and after determination of peak oxygen uptake (VO2Peak) and the speed associated with VO2Peak (sVO2Peak), the subjects completed 2 random experimental trials: high-intensity exercise (HIE - 1:1 at 100% sVO2Peak), and moderate-intensity continuous exercise (MIE - 70% sVO2Peak). HRV and RR intervals were monitored before, during and after the exercise sessions together with, the HRV analysis in the frequency domains (high-frequency - HF: 0.15 to 0.4 Hz and low-frequency - LF: 0.04 to 0.15 Hz components) and the ratio between them (LF/HF). Statistical analysis comparisons between moments and between HIE and MIE were performed using a mixed model. Both exercise sessions modified LFlog, HFlog, and LF/HF (F=16.54, F=19.32 and F=5.17, p<0.05, respectively). A group effect was also found for LFlog (F=23.91, p<0.05), and HFlog (F=57.55, p< 0.05). LF/HF returned to resting value 15 min after MIE exercise and 20 min after HIE exercise. This means that the heavy domain (aerobic and anaerobic threshold) induces dissimilar autonomic modification in physically active subjects. Both HIE and MIE modify HRV, and generally HIE delays parasympathetic autonomic modulation recovery after iso-volume exercise. © Georg Thieme Verlag KG Stuttgart · New York.

  4. A New Strategy to Enhance Cavitational Tissue Erosion Using a High-Intensity, Initiating Sequence

    PubMed Central

    Xu, Zhen; Fowlkes, J. Brian; Cain, Charles A.

    2009-01-01

    Our previous studies have shown that pulsed ultrasound can physically remove soft tissue through cavitation. A new strategy to enhance the cavitation-induced erosion is proposed wherein tissue erosion is initiated by a short, high-intensity sequence of pulses and sustained by lower intensity pulses. We investigated effects of the initiating sequence on erosion and cavitation sustained by lower intensity pulses. Multiple three-cycle pulses at a pulse repetition frequency of 20 kHz delivered by a 788-kHz focused transducer were used for tissue erosion. Fixing the initiating sequence at ISPPA of 9000 W/cm2, 16 combinations of different numbers of pulses within the initiating sequence and different sustaining pulse intensities were tested. Results showed: the initiating sequence increases the probability of erosion occurrence and the erosion rate with only slight overall increases in propagated energy; the initiating sequence containing more pulses does not increase the sustained cavitation period; and if extinguished and reinitiated, the sustained cavitation period becomes shorter after each initiation, although the waiting time between adjacent cavitation periods is random. The high-intensity, initiating sequence enhances cavitational tissue erosion and enables erosion at intensities significantly lower than what is required to initiate erosion. PMID:16921893

  5. Charcoal Reflectance Reveals Early Holocene Boreal Deciduous Forests Burned at High Intensities

    PubMed Central

    Hudspith, Victoria A.; Belcher, Claire M.; Kelly, Ryan; Hu, Feng Sheng

    2015-01-01

    Wildfire size, frequency, and severity are increasing in the Alaskan boreal forest in response to climate warming. One of the potential impacts of this changing fire regime is the alteration of successional trajectories, from black spruce to mixed stands dominated by aspen, a vegetation composition not experienced since the early Holocene. Such changes in vegetation composition may consequently alter the intensity of fires, influencing fire feedbacks to the ecosystem. Paleorecords document past wildfire-vegetation dynamics and as such, are imperative for our understanding of how these ecosystems will respond to future climate warming. For the first time, we have used reflectance measurements of macroscopic charcoal particles (>180μm) from an Alaskan lake-sediment record to estimate ancient charring temperatures (termed pyrolysis intensity). We demonstrate that pyrolysis intensity increased markedly from an interval of birch tundra 11 ky ago (mean 1.52%Ro; 485°C), to the expansion of trees on the landscape ∼10.5 ky ago, remaining high to the present (mean 3.54%Ro; 640°C) irrespective of stand composition. Despite differing flammabilities and adaptations to fire, the highest pyrolysis intensities derive from two intervals with distinct vegetation compositions. 1) the expansion of mixed aspen and spruce woodland at 10 cal. kyr BP, and 2) the establishment of black spruce, and the modern boreal forest at 4 cal. kyr BP. Based on our analysis, we infer that predicted expansion of deciduous trees into the boreal forest in the future could lead to high intensity, but low severity fires, potentially moderating future climate-fire feedbacks. PMID:25853712

  6. Charcoal reflectance reveals early holocene boreal deciduous forests burned at high intensities.

    PubMed

    Hudspith, Victoria A; Belcher, Claire M; Kelly, Ryan; Hu, Feng Sheng

    2015-01-01

    Wildfire size, frequency, and severity are increasing in the Alaskan boreal forest in response to climate warming. One of the potential impacts of this changing fire regime is the alteration of successional trajectories, from black spruce to mixed stands dominated by aspen, a vegetation composition not experienced since the early Holocene. Such changes in vegetation composition may consequently alter the intensity of fires, influencing fire feedbacks to the ecosystem. Paleorecords document past wildfire-vegetation dynamics and as such, are imperative for our understanding of how these ecosystems will respond to future climate warming. For the first time, we have used reflectance measurements of macroscopic charcoal particles (>180μm) from an Alaskan lake-sediment record to estimate ancient charring temperatures (termed pyrolysis intensity). We demonstrate that pyrolysis intensity increased markedly from an interval of birch tundra 11 ky ago (mean 1.52%Ro; 485°C), to the expansion of trees on the landscape ~10.5 ky ago, remaining high to the present (mean 3.54%Ro; 640°C) irrespective of stand composition. Despite differing flammabilities and adaptations to fire, the highest pyrolysis intensities derive from two intervals with distinct vegetation compositions. 1) the expansion of mixed aspen and spruce woodland at 10 cal. kyr BP, and 2) the establishment of black spruce, and the modern boreal forest at 4 cal. kyr BP. Based on our analysis, we infer that predicted expansion of deciduous trees into the boreal forest in the future could lead to high intensity, but low severity fires, potentially moderating future climate-fire feedbacks.

  7. 36 CFR § 910.31 - High architectural quality.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 36 Parks, Forests, and Public Property 3 2013-07-01 2012-07-01 true High architectural quality. Â... PENNSYLVANIA AVENUE DEVELOPMENT AREA Standards Uniformly Applicable to the Development Area § 910.31 High architectural quality. Development must maintain a uniformly high standard of architecture, representative of...

  8. High Intensity Tests of the NuMI Beam Monitoring Ionization Chambers

    NASA Astrophysics Data System (ADS)

    Zwaska, Robert

    2002-04-01

    The NuMI facility at Fermilab will generate an intense beam of neutrinos directed toward Soudan, MN, 735 km away. Components of the planned beam monitoring system will be exposed to fluences of up to 8 x 10^9 charge particles / cm^2 and 6 x 10^10 neutrons / cm^2 in an 8.6 us beam spill. These fluences will be measured by an array of Helium ionization chambers. We tested a pair of chambers with 8 GeV protons at the Fermilab Booster accelerator, and with high intensity neutron sources at the Texas Experimental Nuclear Facility.

  9. NASA's New High Intensity Solar Environment Test Capability

    NASA Technical Reports Server (NTRS)

    Schneider, Todd A.; Vaughn, Jason A.; Wright, Kenneth H.

    2012-01-01

    Across the world, new spaceflight missions are being designed and executed that will place spacecraft and instruments into challenging environments throughout the solar system. To aid in the successful completion of these new missions, NASA has developed a new flexible space environment test platform. The High Intensity Solar Environment Test (HISET) capability located at NASA fs Marshall Space Flight Center provides scientists and engineers with the means to test spacecraft materials and systems in a wide range of solar wind and solar photon environments. Featuring a solar simulator capable of delivering approximately 1 MW/m2 of broad spectrum radiation at maximum power, HISET provides a means to test systems or components that could explore the solar corona. The solar simulator consists of three high-power Xenon arc lamps that can be operated independently over a range of power to meet test requirements; i.e., the lamp power can be greatly reduced to simulate the solar intensity at several AU. Integral to the HISET capability are charged particle sources that can provide a solar wind (electron and proton) environment. Used individually or in combination, the charged particle sources can provide fluxes ranging from a few nA/cm2 to 100s of nA/cm2 over an energy range of 50 eV to 100 keV for electrons and 100 eV to 30 keV for protons. Anchored by a high vacuum facility equipped with a liquid nitrogen cold shroud for radiative cooling scenarios, HISET is able to accommodate samples as large as 1 meter in diameter. In this poster, details of the HISET capability will be presented, including the wide ]ranging configurability of the system.

  10. Formation of a high intensity low energy positron string

    NASA Astrophysics Data System (ADS)

    Donets, E. D.; Donets, E. E.; Syresin, E. M.; Itahashi, T.; Dubinov, A. E.

    2004-05-01

    The possibility of a high intensity low energy positron beam production is discussed. The proposed Positron String Trap (PST) is based on the principles and technology of the Electron String Ion Source (ESIS) developed in JINR during the last decade. A linear version of ESIS has been used successfully for the production of intense highly charged ion beams of various elements. Now the Tubular Electron String Ion Source (TESIS) concept is under study and this opens really new promising possibilities in physics and technology. In this report, we discuss the application of the tubular-type trap for the storage of positrons cooled to the cryogenic temperatures of 0.05 meV. It is intended that the positron flux at the energy of 1-5 eV, produced by the external source, is injected into the Tubular Positron Trap which has a similar construction as the TESIS. Then the low energy positrons are captured in the PST Penning trap and are cooled down because of their synchrotron radiation in the strong (5-10 T) applied magnetic field. It is expected that the proposed PST should permit storing and cooling to cryogenic temperature of up to 5×109 positrons. The accumulated cooled positrons can be used further for various physics applications, for example, antihydrogen production.

  11. Comparison of responses to two high-intensity intermittent exercise protocols.

    PubMed

    Gist, Nicholas H; Freese, Eric C; Cureton, Kirk J

    2014-11-01

    The purpose of this study was to compare peak cardiorespiratory, metabolic, and perceptual responses to acute bouts of sprint interval cycling (SIC) and a high-intensity intermittent calisthenics (HIC) protocol consisting of modified "burpees." Eleven (8 men and 3 women) moderately trained, college-aged participants (age = 21.9 ± 2.1, body mass index = 24.8 ± 1.9, V[Combining Dot Above]O2peak = 54.1 ± 5.4 ml·kg·min) completed 4 testing sessions across 9 days with each session separated by 48-72 hours. Using a protocol of 4 repeated bouts of 30-second "all-out" efforts interspersed with 4-minute active recovery periods, responses to SIC and HIC were classified relative to peak values. Mean values for %V[Combining Dot Above]O2peak and %HRpeak for SIC (80.4 ± 5.3% and 86.8 ± 3.9%) and HIC (77.6 ± 6.9% and 84.6 ± 5.3%) were not significantly different (p > 0.05). Effect sizes (95% confidence interval) calculated for mean differences were: %V[Combining Dot Above]O2peak Cohen's d = 0.51 (0.48-0.53) and %HRpeak Cohen's d = 0.57 (0.55-0.59). A low-volume, high-intensity bout of repeated whole-body calisthenic exercise induced cardiovascular responses that were not significantly different but were ∼1/2SD lower than "all-out" SIC. These results suggest that in addition to the benefit of reduced time commitment, a high-intensity interval protocol of calisthenics elicits vigorous cardiorespiratory and perceptual responses and may confer physiological adaptations and performance improvements similar to those reported for SIC. The potential efficacy of this alternative interval training method provides support for its application by athletes, coaches, and strength and conditioning professionals.

  12. Comparison of affective responses during and after low volume high-intensity interval exercise, continuous moderate- and continuous high-intensity exercise in active, untrained, healthy males.

    PubMed

    Niven, Ailsa; Thow, Jacqueline; Holroyd, Jack; Turner, Anthony P; Phillips, Shaun M

    2018-09-01

    This study compared affective responses to low volume high-intensity interval exercise (HIIE), moderate-intensity continuous exercise (MICE) and high-intensity continuous exercise (HICE). Twelve untrained males ([Formula: see text] 48.2 ± 6.7 ml·kg -1 ·min -1 ) completed MICE (30 min cycle at 85% of ventilatory threshold (VT)), HICE (cycle at 105% of VT matched with MICE for total work), and HIIE (10 x 6 s cycle sprints with 60 s recovery). Affective valence and perceived activation were measured before exercise, post warm-up, every 20% of exercise time, and 1, 5, 10, and 15 min post-exercise. Affective valence during exercise declined by 1.75 ± 2.42, 1.17 ± 1.99, and 0.42 ± 1.38 units in HICE, HIIE, and MICE, respectively, but was not statistically influenced by trial (P = 0.35), time (P = 0.06), or interaction effect (P = 0.08). Affective valence during HICE and HIIE was consistently less positive than MICE. Affective valence post-exercise was not statistically influenced by trial (P = 0.10) and at 5 min post-exercise exceeded end-exercise values (P = 0.048). Circumplex profiles showed no negative affect in any trial. Affective responses to low volume HIIE are similar to HICE but remain positive and rebound rapidly, suggesting it may be a potential alternative exercise prescription.

  13. The impact of on-site wastewater from high density cluster developments on groundwater quality

    NASA Astrophysics Data System (ADS)

    Morrissey, P. J.; Johnston, P. M.; Gill, L. W.

    2015-11-01

    The net impact on groundwater quality from high density clusters of unsewered housing across a range of hydro(geo)logical settings has been assessed. Four separate cluster development sites were selected, each representative of different aquifer vulnerability categories. Groundwater samples were collected on a monthly basis over a two year period for chemical and microbiological analysis from nested multi-horizon sampling boreholes upstream and downstream of the study sites. The field results showed no statistically significant difference between upstream and downstream water quality at any of the study areas, although there were higher breakthroughs in contaminants in the High and Extreme vulnerability sites linked to high intensity rainfall events; these however, could not be directly attributed to on-site effluent. Linked numerical models were then built for each site using HYDRUS 2D to simulate the attenuation of contaminants through the unsaturated zone from which the resulting hydraulic and contaminant fluxes at the water table were used as inputs into MODFLOW MT3D models to simulate the groundwater flows. The results of the simulations confirmed the field observations at each site, indicating that the existing clustered on-site wastewater discharges would only cause limited and very localised impacts on groundwater quality, with contaminant loads being quickly dispersed and diluted downstream due to the relatively high groundwater flow rates. Further simulations were then carried out using the calibrated models to assess the impact of increasing cluster densities revealing little impact at any of the study locations up to a density of 6 units/ha with the exception of the Extreme vulnerability site.

  14. Efficient coupling of high intensity short laser pulses into snow clusters

    NASA Astrophysics Data System (ADS)

    Palchan, T.; Pecker, S.; Henis, Z.; Eisenmann, S.; Zigler, A.

    2007-01-01

    Measurements of energy absorption of high intensity laser pulses in snow clusters are reported. Targets consisting of sapphire coated with snow nanoparticles were found to absorb more than 95% of the incident light compared to 50% absorption in flat sapphire targets.

  15. Reliable detection of fluence anomalies in EPID-based IMRT pretreatment quality assurance using pixel intensity deviations

    PubMed Central

    Gordon, J. J.; Gardner, J. K.; Wang, S.; Siebers, J. V.

    2012-01-01

    Purpose: This work uses repeat images of intensity modulated radiation therapy (IMRT) fields to quantify fluence anomalies (i.e., delivery errors) that can be reliably detected in electronic portal images used for IMRT pretreatment quality assurance. Methods: Repeat images of 11 clinical IMRT fields are acquired on a Varian Trilogy linear accelerator at energies of 6 MV and 18 MV. Acquired images are corrected for output variations and registered to minimize the impact of linear accelerator and electronic portal imaging device (EPID) positioning deviations. Detection studies are performed in which rectangular anomalies of various sizes are inserted into the images. The performance of detection strategies based on pixel intensity deviations (PIDs) and gamma indices is evaluated using receiver operating characteristic analysis. Results: Residual differences between registered images are due to interfraction positional deviations of jaws and multileaf collimator leaves, plus imager noise. Positional deviations produce large intensity differences that degrade anomaly detection. Gradient effects are suppressed in PIDs using gradient scaling. Background noise is suppressed using median filtering. In the majority of images, PID-based detection strategies can reliably detect fluence anomalies of ≥5% in ∼1 mm2 areas and ≥2% in ∼20 mm2 areas. Conclusions: The ability to detect small dose differences (≤2%) depends strongly on the level of background noise. This in turn depends on the accuracy of image registration, the quality of the reference image, and field properties. The longer term aim of this work is to develop accurate and reliable methods of detecting IMRT delivery errors and variations. The ability to resolve small anomalies will allow the accuracy of advanced treatment techniques, such as image guided, adaptive, and arc therapies, to be quantified. PMID:22894421

  16. Communication and quality of life outcomes from an interprofessional intensive, comprehensive, aphasia program (ICAP).

    PubMed

    Hoover, Elizabeth L; Caplan, David N; Waters, Gloria S; Carney, Anne

    2017-03-01

    Intensive Comprehensive Aphasia Programs (ICAPs) have developed in response to a growing need for treatments which produce changes in language function in people with aphasia, especially in the chronic phase of recovery. ICAPs are growing in number and several papers have presented preliminary results of their use, but little data exist about their efficacy or effectiveness. This paper explores the communication effects of an ICAP program that incorporated evidenced-based individual and group treatment in an interprofessional program. Twenty-seven individuals with chronic aphasia were provided with 30 h of interprofessional treatment a week for a four-week period in both individual and group formats. A delayed treatment, within-participant research protocol was used. Language measures were taken at two intervals pre- and two intervals post treatment. Functional, narrative, and quality of life measures were taken once pre and once post treatment. Significant change was observed on targeted language functions post treatment. Significant treatment effects were also observed on functional and quality of life measures as well as on all impairment-based language measures for the group. The results provide evidence of linguistic and quality of life change in individuals with chronic aphasia who were treated in an interprofessional ICAP.

  17. Intrinsic phonon bands in high quality monolayer T' molybdenum ditelluride

    NASA Astrophysics Data System (ADS)

    Chen, Shao-Yu; Naylor, Carl; Goldstein, Thomas; Johnson, Charlie; Yan, Jun

    Distorted octahedral (T') transition metal dichalcogenide (TMDC) is a type of layered semimetal that has attracted significant recent attention because of its fascination physical, chemical and nontrivial topological properties. Unlike its hexagonal counterpart, monolayer (1L) T'-TMDC is challenging to work with due to rapid sample degradation in air. In this talk, I will discuss well-protected 1L-T' - MoTe2 that exhibits sharp and robust intrinsic Raman bands, with intensities about one order of magnitude stronger than those from bulk T'-MoTe2. The high quality samples enable us to reveal for the first time the set of all nine even-parity zone-center optical phonons. Crystal angle and light polarization resolved measurements further indicate that all the intrinsic Raman modes belong to either z-mode (vibrating along the zigzag Mo atomic chain) or m-modes (vibrating in the mirror plane). Moreover, with the knowledge of vibrational symmetry, we can effectively distinguish the intrinsic modes from Te-metalloid-like modes with energy around 122 and 141 cm-1 which are associated to the sample degradation. Our studies offer a powerful non-destructive method for assessing sample quality, providing the fingerprint as well as key insights in understanding the fundamental properties of 1L T'-TMDCs.

  18. Validation of the Amsterdam Dynamic Facial Expression Set – Bath Intensity Variations (ADFES-BIV): A Set of Videos Expressing Low, Intermediate, and High Intensity Emotions

    PubMed Central

    Wingenbach, Tanja S. H.

    2016-01-01

    Most of the existing sets of facial expressions of emotion contain static photographs. While increasing demand for stimuli with enhanced ecological validity in facial emotion recognition research has led to the development of video stimuli, these typically involve full-blown (apex) expressions. However, variations of intensity in emotional facial expressions occur in real life social interactions, with low intensity expressions of emotions frequently occurring. The current study therefore developed and validated a set of video stimuli portraying three levels of intensity of emotional expressions, from low to high intensity. The videos were adapted from the Amsterdam Dynamic Facial Expression Set (ADFES) and termed the Bath Intensity Variations (ADFES-BIV). A healthy sample of 92 people recruited from the University of Bath community (41 male, 51 female) completed a facial emotion recognition task including expressions of 6 basic emotions (anger, happiness, disgust, fear, surprise, sadness) and 3 complex emotions (contempt, embarrassment, pride) that were expressed at three different intensities of expression and neutral. Accuracy scores (raw and unbiased (Hu) hit rates) were calculated, as well as response times. Accuracy rates above chance level of responding were found for all emotion categories, producing an overall raw hit rate of 69% for the ADFES-BIV. The three intensity levels were validated as distinct categories, with higher accuracies and faster responses to high intensity expressions than intermediate intensity expressions, which had higher accuracies and faster responses than low intensity expressions. To further validate the intensities, a second study with standardised display times was conducted replicating this pattern. The ADFES-BIV has greater ecological validity than many other emotion stimulus sets and allows for versatile applications in emotion research. It can be retrieved free of charge for research purposes from the corresponding author

  19. Intensive Exercise Training During Bed Rest Attenuates Deconditioning

    NASA Technical Reports Server (NTRS)

    Greenleaf, John E.

    1997-01-01

    Intensive exercise training during bed rest attenuates deconditioning. Med. Sci. Sports Exerc., Vol. 29, No. 2, pp. 207-215, 1997. A 30-d 6 deg head-down bed rest project was conducted to evaluate variable high-intensity, short-duration, isotonic cycle ergometer exercise (ITE) training and high-intensity intermittent resistive isokinetic exercise (IKE) training regimens designed to maintain peak VO2 and muscle mass, strength, and endurance at ambulatory control levels throughout prolonged bed rest. Other elements of the deconditioning (adaptive) syndrome, such as proprioception, psychological performance, hypovolemia, water balance, body composition, and orthostatic tolerance, were also measured. Major findings are summarized in this paper. Compared with response during bed rest of the no exercise (NOE) control group: the ITE training regimen (a) maintained work capacity (peak VO2), (b) maintained plasma and red cell volumes, (c) induced positive body water balance, (d) decreased quality of sleep and mental concentration, and (e) had no effect on the decrease in orthostatic tolerance; the IKE training regimen (f) attenuated the decrease in peak VO2 by 50%, (g) attenuated loss of red cell volume by 40% but had no effect on loss of plasma volume, (b) induced positive body water balance, (i) had no adverse effect on quality of sleep or concentration, and 0) had no effect on the decrease in orthostatic tolerance. These findings suggest that various elements of the deconditioning syndrome can be manipulated by duration and intensity of ITE or IKE training regimens and that several different training protocols will be required to maintain or restore physiological and psychological performance of individuals confined to prolonged bed rest.

  20. Steganography based on pixel intensity value decomposition

    NASA Astrophysics Data System (ADS)

    Abdulla, Alan Anwar; Sellahewa, Harin; Jassim, Sabah A.

    2014-05-01

    This paper focuses on steganography based on pixel intensity value decomposition. A number of existing schemes such as binary, Fibonacci, Prime, Natural, Lucas, and Catalan-Fibonacci (CF) are evaluated in terms of payload capacity and stego quality. A new technique based on a specific representation is proposed to decompose pixel intensity values into 16 (virtual) bit-planes suitable for embedding purposes. The proposed decomposition has a desirable property whereby the sum of all bit-planes does not exceed the maximum pixel intensity value, i.e. 255. Experimental results demonstrate that the proposed technique offers an effective compromise between payload capacity and stego quality of existing embedding techniques based on pixel intensity value decomposition. Its capacity is equal to that of binary and Lucas, while it offers a higher capacity than Fibonacci, Prime, Natural, and CF when the secret bits are embedded in 1st Least Significant Bit (LSB). When the secret bits are embedded in higher bit-planes, i.e., 2nd LSB to 8th Most Significant Bit (MSB), the proposed scheme has more capacity than Natural numbers based embedding. However, from the 6th bit-plane onwards, the proposed scheme offers better stego quality. In general, the proposed decomposition scheme has less effect in terms of quality on pixel value when compared to most existing pixel intensity value decomposition techniques when embedding messages in higher bit-planes.

  1. Propagation of Sound at Moderate and High Intensities in Absorbent and Hard-Walled Cylindrical Ducts. Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Mcdaniel, Oliver Herbert

    1975-01-01

    The propagation of plane wave and higher order acoustic modes in both hard-walled and absorbent cylindrical ducts was studied at moderate sound intensities where the linear wave equation is valid, and at high intensities where nonlinear effects can be observed. The experiments were conducted with an anechoically terminated twelve-inch inside-diameter transite pipe. Various types of sound sources were mounted at one end of the duct to generate the desired acoustic fields within the duct. Arrays of conventional loudspeakers were used to generate plane waves and higher order acoustic modes at moderate intensities, and an array of four high intensity electro-pneumatic sound sources was used for the experiments in the nonlinear region. The attenuation of absorbent liners made of several different materials was obtained at moderate intensities for both plane waves and high order modes. It was found that the characteristics of the liners studied did not change appreciably at high intensities.

  2. The relationship between mindfulness, pain intensity, pain catastrophizing, depression, and quality of life among cancer survivors living with chronic neuropathic pain.

    PubMed

    Poulin, Patricia A; Romanow, Heather C; Rahbari, Noriyeh; Small, Rebecca; Smyth, Catherine E; Hatchard, Taylor; Solomon, Brahm K; Song, Xinni; Harris, Cheryl A; Kowal, John; Nathan, Howard J; Wilson, Keith G

    2016-10-01

    This study aims to examine if mindfulness is associated with pain catastrophizing, depression, disability, and health-related quality of life (HRQOL) in cancer survivors with chronic neuropathic pain (CNP). We conducted a cross-sectional survey with cancer survivors experiencing CNP. Participants (n = 76) were men (24 %) and women (76 %) with an average age of 56.5 years (SD = 9.4). Participants were at least 1 year post-treatment, with no evidence of cancer, and with symptoms of neuropathic pain for more than three months. Participants completed the Five Facets Mindfulness Questionnaire (FFMQ), along with measures of pain intensity, pain catastrophizing, pain interference, depression, and HRQOL. Mindfulness was negatively correlated with pain intensity, pain catastrophizing, pain interference, and depression, and it was positively correlated with mental health-related HRQOL. Regression analyses demonstrated that mindfulness was a negative predictor of pain intensity and depression and a positive predictor of mental HRQOL after controlling for pain catastrophizing, age, and gender. The two mindfulness facets that were most consistently associated with better outcomes were non-judging and acting with awareness. Mindfulness significantly moderated the relationships between pain intensity and pain catastrophizing and between pain intensity and pain interference. It appears that mindfulness mitigates the impact of pain experiences in cancer survivors experiencing CNP post-treatment. This study suggests that mindfulness is associated with better adjustment to CNP. This provides the foundation to explore whether mindfulness-based interventions improve quality of life among cancer survivors living with CNP.

  3. No Effect of Exercise Intensity on Appetite in Highly-Trained Endurance Women

    PubMed Central

    Howe, Stephanie M.; Hand, Taryn M.; Larson-Meyer, D. Enette; Austin, Kathleen J.; Alexander, Brenda M.; Manore, Melinda M.

    2016-01-01

    In endurance-trained men, an acute bout of exercise is shown to suppress post-exercise appetite, yet limited research has examined this response in women. The purpose of this study was to investigate the effect of exercise intensity on appetite and gut hormone responses in endurance-trained women. Highly-trained women (n = 15, 18–40 years, 58.4 ± 6.4 kg, VO2MAX = 55.2 ± 4.3 mL/kg/min) completed isocaloric bouts (500 kcals or 2093 kJ) of moderate-intensity (MIE, 60% VO2MAX) and high-intensity (HIE, 85% VO2MAX) treadmill running at the same time of day, following a similar 48-h diet/exercise period, and at least 1-week apart. Blood was drawn pre-exercise (baseline), immediately post-exercise and every 20-min for the next 60-min. Plasma concentrations of acylated ghrelin, PYY3–36, GLP-1 and subjective appetite ratings via visual analog scale (VAS) were assessed at each time point. Acylated ghrelin decreased (p = 0.014) and PYY3–36 and GLP-1 increased (p = 0.036, p < 0.0001) immediately post-exercise, indicating appetite suppression. VAS ratings of hunger and desire to eat decreased immediately post-exercise (p = 0.0012, p = 0.0031, respectively), also indicating appetite suppression. There were no differences between exercise intensities for appetite hormones or VAS. Similar to males, post-exercise appetite regulatory hormones were altered toward suppression in highly-trained women and independent of energy cost of exercise. Results are important for female athletes striving to optimize nutrition for endurance performance. PMID:27096869

  4. Bremsstrahlung Dose Yield for High-Intensity Short-Pulse Laser–Solid Experiments

    DOE PAGES

    Liang, Taiee; Bauer, Johannes M.; Liu, James C.; ...

    2016-12-01

    A bremsstrahlung source term has been developed by the Radiation Protection (RP) group at SLAC National Accelerator Laboratory for high-intensity short-pulse laser–solid experiments between 10 17 and 10 22 W cm –2. This source term couples the particle-in-cell plasma code EPOCH and the radiation transport code FLUKA to estimate the bremsstrahlung dose yield from laser–solid interactions. EPOCH characterizes the energy distribution, angular distribution, and laser-to-electron conversion efficiency of the hot electrons from laser–solid interactions, and FLUKA utilizes this hot electron source term to calculate a bremsstrahlung dose yield (mSv per J of laser energy on target). The goal of thismore » paper is to provide RP guidelines and hazard analysis for high-intensity laser facilities. In conclusion, a comparison of the calculated bremsstrahlung dose yields to radiation measurement data is also made.« less

  5. Bremsstrahlung Dose Yield for High-Intensity Short-Pulse Laser–Solid Experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liang, Taiee; Bauer, Johannes M.; Liu, James C.

    A bremsstrahlung source term has been developed by the Radiation Protection (RP) group at SLAC National Accelerator Laboratory for high-intensity short-pulse laser–solid experiments between 10 17 and 10 22 W cm –2. This source term couples the particle-in-cell plasma code EPOCH and the radiation transport code FLUKA to estimate the bremsstrahlung dose yield from laser–solid interactions. EPOCH characterizes the energy distribution, angular distribution, and laser-to-electron conversion efficiency of the hot electrons from laser–solid interactions, and FLUKA utilizes this hot electron source term to calculate a bremsstrahlung dose yield (mSv per J of laser energy on target). The goal of thismore » paper is to provide RP guidelines and hazard analysis for high-intensity laser facilities. In conclusion, a comparison of the calculated bremsstrahlung dose yields to radiation measurement data is also made.« less

  6. Men and Women Exhibit Similar Acute Hypotensive Responses After Low, Moderate, or High-Intensity Plyometric Training.

    PubMed

    Ramírez-Campillo, Rodrigo; Abad-Colil, Felipe; Vera, Maritza; Andrade, David C; Caniuqueo, Alexis; Martínez-Salazar, Cristian; Nakamura, Fábio Y; Arazi, Hamid; Cerda-Kohler, Hugo; Izquierdo, Mikel; Alonso-Martínez, Alicia M

    2016-01-01

    The aim of this study was to compare the acute effects of low-, moderate-, high-, and combined-intensity plyometric training on heart rate (HR), systolic blood pressure (SBP), diastolic blood pressure (DBP), and rate-pressure product (RPP) cardiovascular responses in male and female normotensive subjects. Fifteen (8 women) physically active normotensive subjects participated in this study (age 23.5 ± 2.6 years, body mass index 23.8 ± 2.3 kg · m(-2)). Using a randomized crossover design, trials were conducted with rest intervals of at least 48 hours. Each trial comprised 120 jumps, using boxes of 20, 30, and 40 cm for low, moderate, and high intensity, respectively. For combined intensity, the 3 height boxes were combined. Measurements were taken before and after (i.e., every 10 minutes for a period of 90 minutes) each trial. When data responses of men and women were combined, a mean reduction in SBP, DBP, and RPP was observed after all plyometric intensities. No significant differences were observed pre- or postexercise (at any time point) for HR, SBP, DBP, or RPP when low-, moderate-, high-, or combined-intensity trials were compared. No significant differences were observed between male and female subjects, except for a higher SBP reduction in women (-12%) compared with men (-7%) after high-intensity trial. Although there were minor differences across postexercise time points, collectively, the data demonstrated that all plyometric training intensities can induce an acute postexercise hypotensive effect in young normotensive male and female subjects.

  7. Differences in acoustic and perceptual parameters of the voice between elderly and young women at habitual and high intensity.

    PubMed

    Mazzetto de Menezes, Keyla S; Master, Suely; Guzman, Marco; Bortnem, Cori; Ramos, Luiz Roberto

    2014-01-01

    The present study aimed to compare elderly and young female voices in habitual and high intensity. The effect of increased intensity on the acoustic and perceptual parameters was assessed. Sound pressure level, fundamental frequency, jitter, shimmer, and harmonic to noise ratio were obtained at habitual and high intensity voice in a group of 30 elderly women and 30 young women. Perceptual assessment was also performed. Both groups demonstrated an increase in sound pressure level and fundamental frequency from habitual voice to high intensity voice. No differences were found between groups in any acoustic variables on samples recorded with habitual intensity level. No significant differences between groups were found in habitual intensity level for pitch, hoarseness, roughness, and breathiness. Asthenia and instability obtained significant higher values in elderly than young participants, whereas, the elderly demonstrated lower values for perceived tension and loudness than young subjects. Acoustic and perceptual measures do not demonstrate evident differences between elderly and young speakers in habitual intensity level. The parameters analyzed may lack the sensitivity necessary to detect differences in subjects with normal voices. Phonation with high intensity highlights differences between groups, especially in perceptual parameters. Therefore, high intensity should be included to compare elderly and young voice. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  8. High beam quality and high energy short-pulse laser with MOPA

    NASA Astrophysics Data System (ADS)

    Jin, Quanwei; Pang, Yu; Jiang, JianFeng; Tan, Liang; Cui, Lingling; Wei, Bin; Sun, Yinhong; Tang, Chun

    2018-03-01

    A high energy, high beam quality short-pulse diode-pumped Nd:YAG master oscillator power-amplifier (MOPA) laser with two amplifier stages is demonstrated. The two-rod birefringence compensation was used as beam quality controlling methods, which presents a short-pulse energy of 40 mJ with a beam quality value of M2 = 1.2 at a repetition rate of 400Hz. The MOPA system delivers a short-pulse energy of 712.5 mJ with a pulse width of 12.4 ns.The method of spherical aberration compensation is improved the beam quality, a M2 factor of 2.3 and an optical-to-optical efficiency of 27.7% is obtained at the maximum laser out power.The laser obtained 1.4J out energy with polarization integration.

  9. Effect of high-intensity interval exercise on lipid oxidation during postexercise recovery.

    PubMed

    Malatesta, Davide; Werlen, Catherine; Bulfaro, Stefano; Chenevière, Xavier; Borrani, Fabio

    2009-02-01

    The aim of this study was to examine whether lipid oxidation predominates during 3 h of postexercise recovery in high-intensity interval exercise as compared with moderate-intensity continuous exercise on a cycle ergometer in fit young men (n = 12; 24.6 +/- 0.6 yr). The energy substrate partitioning was evaluated during and after high-intensity submaximal interval exercise (INT, 1-min intervals at 80% of maximal aerobic power output [Wmax] with an intervening 1 min of active recovery at 40% Wmax) and 60-min moderate-intensity continuous exercise at 45% of maximal oxygen uptake (C45%) as well as a time-matched resting control trial (CON). Exercise bouts were matched for mechanical work output. During exercise, a significantly greater contribution of CHO and a lower contribution of lipid to energy expenditure were found in INT (512.7 +/- 26.6 and 41.0 +/- 14.0 kcal, respectively) than in C45% (406.3 +/- 21.2 and 170.3 +/- 24.0 kcal, respectively; P < 0.001) despite similar overall energy expenditure in both exercise trials (P = 0.13). During recovery, there were no significant differences between INT and C45% in substrate turnover and oxidation (P > 0.05). On the other hand, the mean contribution of lipids to energy yield was significantly higher after exercise trials (C45% = 61.3 +/- 4.2 kcal; INT = 66.7 +/- 4.7 kcal) than after CON (51.5 +/- 3.4 kcal; P < 0.05). These findings show that lipid oxidation during postexercise recovery was increased by a similar amount on two isoenergetic exercise bouts of different forms and intensities compared with the time-matched no-exercise control trial.

  10. Rate modulation of human anconeus motor units during high-intensity dynamic elbow extensions.

    PubMed

    Cowling, Brianna L; Harwood, Brad; Copithorne, David B; Rice, Charles L

    2016-08-01

    Investigations of high-intensity isometric fatiguing protocols report decreases in motor unit firing rates (MUFRs), but little is known regarding changes in MUFRs following fatigue induced by high-intensity dynamic contractions. Our purpose was to evaluate MUFRs of the anconeus (an accessory elbow extensor) and elbow extension power production as a function of time to task failure (TTF) during high-velocity fatiguing concentric contractions against a moderately heavy resistance. Fine-wire intramuscular electrode pairs were inserted into the anconeus to record MUs in 12 male participants (25 ± 3 yr), over repeated sessions on separate days. MUs were tracked throughout a three-stage, varying load dynamic elbow extension protocol designed to extend the task duration for >1 min thereby inducing substantial fatigue. Mean MUFRs and peak power were calculated for three relative time ranges: 0-15% TTF (beginning), 45-60% TTF (middle) and 85-100% TTF (end). Mean duration of the overall fatigue protocol was ∼80 s. Following the protocol, isometric maximum voluntary contraction (MVC), highest velocity at 35% MVC load, and peak power decreased 37, 60, and 64% compared with baseline, respectively. Data from 20 anconeus MUs tracked successfully throughout the protocol indicated a reduction in MUFRs in relation to power loss from 36 Hz/160 W (0-15% TTF) to 28 Hz/97 W (45-60% TTF) to 23 Hz/43 W (85-100% TTF). During these high-intensity maximal effort concentric contractions, anconeus MUFRs decreased substantially (>35%). Although the absolute MUFRs were higher in the present study than those reported previously for other muscles during sustained high-intensity isometric tasks, the relative decrease in MUFRs was similar between the two tasks. Copyright © 2016 the American Physiological Society.

  11. Experience-based quality control of clinical intensity-modulated radiotherapy planning.

    PubMed

    Moore, Kevin L; Brame, R Scott; Low, Daniel A; Mutic, Sasa

    2011-10-01

    To incorporate a quality control tool, according to previous planning experience and patient-specific anatomic information, into the intensity-modulated radiotherapy (IMRT) plan generation process and to determine whether the tool improved treatment plan quality. A retrospective study of 42 IMRT plans demonstrated a correlation between the fraction of organs at risk (OARs) overlapping the planning target volume and the mean dose. This yielded a model, predicted dose = prescription dose (0.2 + 0.8 [1 - exp(-3 overlapping planning target volume/volume of OAR)]), that predicted the achievable mean doses according to the planning target volume overlap/volume of OAR and the prescription dose. The model was incorporated into the planning process by way of a user-executable script that reported the predicted dose for any OAR. The script was introduced to clinicians engaged in IMRT planning and deployed thereafter. The script's effect was evaluated by tracking δ = (mean dose-predicted dose)/predicted dose, the fraction by which the mean dose exceeded the model. All OARs under investigation (rectum and bladder in prostate cancer; parotid glands, esophagus, and larynx in head-and-neck cancer) exhibited both smaller δ and reduced variability after script implementation. These effects were substantial for the parotid glands, for which the previous δ = 0.28 ± 0.24 was reduced to δ = 0.13 ± 0.10. The clinical relevance was most evident in the subset of cases in which the parotid glands were potentially salvageable (predicted dose <30 Gy). Before script implementation, an average of 30.1 Gy was delivered to the salvageable cases, with an average predicted dose of 20.3 Gy. After implementation, an average of 18.7 Gy was delivered to salvageable cases, with an average predicted dose of 17.2 Gy. In the prostate cases, the rectum model excess was reduced from δ = 0.28 ± 0.20 to δ = 0.07 ± 0.15. On surveying dosimetrists at the end of the study, most reported that the script

  12. Interactive Contributions of Attribution Biases and Emotional Intensity to Child-Friend Interaction Quality During Preadolescence.

    PubMed

    Chen, Xi; McElwain, Nancy L; Lansford, Jennifer E

    2017-12-20

    Using data from a subsample of 913 study children and their friends who participated in the NICHD Study of Early Child Care and Youth Development, the interactive contributions of child-reported attribution biases and teacher-reported child emotional intensity (EI) at Grade 4 (M = 9.9 years) to observed child-friend interaction at Grade 6 (M = 11.9 years) were examined. Study children's hostile attribution bias, combined with high EI, predicted more negative child-friend interaction. In contrast, benign attribution bias, combined with high EI, predicted more positive child-friend interaction. The findings are discussed in light of the "fuel" interpretation of EI, in which high-intensity emotions may motivate children to act on their cognitive biases for better or for worse. © 2017 The Authors. Child Development © 2017 Society for Research in Child Development, Inc.

  13. A High School Intensive Summer Mandarin Course: Program Model and Learner Outcomes

    ERIC Educational Resources Information Center

    Xu, Xiaoqiu; Padilla, Amado M.; Silva, Duarte; Masuda, Norman

    2012-01-01

    This article describes a STARTALK intensive summer high school Mandarin language and culture program that was conducted for three summers. Participants across the three years included 40 Mandarin Level II and 53 Mandarin Level III high school students. Quantitative and qualitative data are presented to show the effectiveness of the program.…

  14. High-intensity laser application in Orthodontics

    PubMed Central

    Sant’Anna, Eduardo Franzotti; Araújo, Mônica Tirre de Souza; Nojima, Lincoln Issamu; da Cunha, Amanda Carneiro; da Silveira, Bruno Lopes; Marquezan, Mariana

    2017-01-01

    ABSTRACT Introduction: In dental practice, low-level laser therapy (LLLT) and high-intensity laser therapy (HILT) are mainly used for dental surgery and biostimulation therapy. Within the Orthodontic specialty, while LLLT has been widely used to treat pain associated with orthodontic movement, accelerate bone regeneration after rapid maxillary expansion, and enhance orthodontic tooth movement, HILT, in turn, has been seen as an alternative for addressing soft tissue complications associated to orthodontic treatment. Objective: The aim of this study is to discuss HILT applications in orthodontic treatment. Methods: This study describes the use of HILT in surgical treatments such as gingivectomy, ulotomy, ulectomy, fiberotomy, labial and lingual frenectomies, as well as hard tissue and other dental restorative materials applications. Conclusion: Despite the many applications for lasers in Orthodontics, they are still underused by Brazilian practitioners. However, it is quite likely that this demand will increase over the next years - following the trend in the USA, where laser therapies are more widely used. PMID:29364385

  15. High-intensity laser application in Orthodontics.

    PubMed

    Sant'Anna, Eduardo Franzotti; Araújo, Mônica Tirre de Souza; Nojima, Lincoln Issamu; Cunha, Amanda Carneiro da; Silveira, Bruno Lopes da; Marquezan, Mariana

    2017-01-01

    In dental practice, low-level laser therapy (LLLT) and high-intensity laser therapy (HILT) are mainly used for dental surgery and biostimulation therapy. Within the Orthodontic specialty, while LLLT has been widely used to treat pain associated with orthodontic movement, accelerate bone regeneration after rapid maxillary expansion, and enhance orthodontic tooth movement, HILT, in turn, has been seen as an alternative for addressing soft tissue complications associated to orthodontic treatment. The aim of this study is to discuss HILT applications in orthodontic treatment. This study describes the use of HILT in surgical treatments such as gingivectomy, ulotomy, ulectomy, fiberotomy, labial and lingual frenectomies, as well as hard tissue and other dental restorative materials applications. Despite the many applications for lasers in Orthodontics, they are still underused by Brazilian practitioners. However, it is quite likely that this demand will increase over the next years - following the trend in the USA, where laser therapies are more widely used.

  16. Implementation and evaluation of a follow-up programme after intensive care treatment: A practice development project.

    PubMed

    van Mol, Margo; Ista, Erwin; van Dijk, Monique

    2018-05-02

    This study aimed to measure the effects of a newly developed follow-up programme on intensive care unit patient quality of care, as perceived by their relatives, and the appropriateness of the programme according to nurses. This before and after implementation study was conducted in a level III intensive care unit for adult patients and related follow-up wards and included 135 intensive care nurses and 105 general ward nurses. The implemented programme included a personalised poster, a revised discharge protocol and follow-up visits on the ward. Eligible relatives of patients who had remained in the intensive care for a minimum of 48 hours were included. Total quality of care and communication were assessed by relatives as high according to the Quality Monitor. Most intensive care nurses evaluated the usefulness of the discharge protocol as positive (71.8% partly/totally agreed) and in accordance with the patients' needs (82.1% partly/totally agreed). Communication and general support as perceived by patients' relatives improved; however, no influence on the total quality of care of the revised discharge protocol was shown. Nurses considered the programme as useful. The intervention might enable nurses to better respond to the instrumental and affective needs of patients and their relatives. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. High-intensity interval training for improving postprandial hyperglycemia.

    PubMed

    Little, Jonathan P; Francois, Monique E

    2014-12-01

    High-intensity interval training (HIIT) has garnered attention in recent years as a time-efficient exercise option for improving cardiovascular and metabolic health. New research demonstrates that HIIT may be particularly effective for improving postprandial hyperglycemia in individuals with, or at risk for, type 2 diabetes (T2D). These findings have clinical relevance because elevated postprandial hyperglycemia is a significant risk factor for cardiovascular morbidity and mortality. This article summarizes the latest evidence demonstrating that HIIT can improve postprandial glucose control to highlight the potential application of HIIT in the prevention and management of T2D and associated cardiovascular complications.

  18. Semicircular Canal Pressure Changes During High-intensity Acoustic Stimulation.

    PubMed

    Maxwell, Anne K; Banakis Hartl, Renee M; Greene, Nathaniel T; Benichoux, Victor; Mattingly, Jameson K; Cass, Stephen P; Tollin, Daniel J

    2017-08-01

    Acoustic stimulation generates measurable sound pressure levels in the semicircular canals. High-intensity acoustic stimuli can cause hearing loss and balance disruptions. To examine the propagation of acoustic stimuli to the vestibular end-organs, we simultaneously measured fluid pressure in the cochlea and semicircular canals during both air- and bone-conducted sound presentation. Five full-cephalic human cadaveric heads were prepared bilaterally with a mastoidectomy and extended facial recess. Vestibular pressures were measured within the superior, lateral, and posterior semicircular canals, and referenced to intracochlear pressure within the scala vestibuli with fiber-optic pressure probes. Pressures were measured concurrently with laser Doppler vibrometry measurements of stapes velocity during stimulation with both air- and bone-conduction. Stimuli were pure tones between 100 Hz and 14 kHz presented with custom closed-field loudspeakers for air-conducted sounds and via commercially available bone-anchored device for bone-conducted sounds. Pressures recorded in the superior, lateral, and posterior semicircular canals in response to sound stimulation were equal to or greater in magnitude than those recorded in the scala vestibuli (up to 20 dB higher). The pressure magnitudes varied across canals in a frequency-dependent manner. High sound pressure levels were recorded in the semicircular canals with sound stimulation, suggesting that similar acoustical energy is transmitted to the semicircular canals and the cochlea. Since these intralabyrinthine pressures exceed intracochlear pressure levels, our results suggest that the vestibular end-organs may also be at risk for injury during exposure to high-intensity acoustic stimuli known to cause trauma in the auditory system.

  19. High intensity exercise or conventional exercise for patients with rheumatoid arthritis? Outcome expectations of patients, rheumatologists, and physiotherapists

    PubMed Central

    Munneke, M; de Jong, Z; Zwinderman, A; Ronday, H; van den Ende, C H M; Vliet, V; Hazes, J

    2004-01-01

    Objective: To examine the outcome expectations of RA patients, rheumatologists, and physiotherapists regarding high intensity exercise programmes compared with conventional exercise programmes. Methods: An exercise outcome expectations questionnaire was administered to 807 RA patients, 153 rheumatologists, and 624 physiotherapists. The questionnaire consisted of four statements regarding positive and negative outcomes of high intensity exercise programmes and four similar statements for conventional exercise programmes. A total expectation score for both conventional and high intensity exercise was calculated, ranging from –2 (very negative expectation) to 2 (very positive expectation). Results: The questionnaire was returned by 662 RA patients (82%), 132 rheumatologists (86%), and 467 physiotherapists (75%). The mean (95% confidence interval) scores for high intensity exercise programmes were 0.30 (0.25 to 0.34), 0.68 (0.62 to 0.74), and –0.06 (–0.15 to 0.02), and for conventional exercise programmes were 0.99 (0.96 to 1.02), 1.13 (1.09 to 1.17), and 1.27 (1.21 to 1.34) for RA patients, rheumatologists, and physiotherapists, respectively. In all three respondent groups, the outcome expectations of high intensity exercise were significantly less positive than those of conventional exercise programme. Conclusions: Despite the existing evidence regarding the effectiveness and safety of high intensity exercise programmes, RA patients, rheumatologists, and physiotherapists have more positive expectations of conventional exercise programmes than of high intensity exercise programmes. Physiotherapists were the least positive about outcomes of high intensity exercise programmes while rheumatologists were the most positive. To help the implementation of new insights in the effectiveness of physical therapy modalities in rheumatology, the need for continuous education of patients, rheumatologists and physiotherapists is emphasised. PMID:15194575

  20. Effect of 24 sessions of high-intensity aerobic interval training carried out at either high or moderate frequency, a randomized trial.

    PubMed

    Hatle, Håvard; Støbakk, Per Kristian; Mølmen, Harald Edvard; Brønstad, Eivind; Tjønna, Arnt Erik; Steinshamn, Sigurd; Skogvoll, Eirik; Wisløff, Ulrik; Ingul, Charlotte Björk; Rognmo, Øivind

    2014-01-01

    The training response of an intensified period of high-intensity exercise is not clear. Therefore, we compared the cardiovascular adaptations of completing 24 high-intensity aerobic interval training sessions carried out for either three or eight weeks, respectively. Twenty-one healthy subjects (23.0±2.1 years, 10 females) completed 24 high-intensity training sessions throughout a time-period of either eight weeks (moderate frequency, MF) or three weeks (high frequency, HF) followed by a detraining period of nine weeks without any training. In both groups, maximal oxygen uptake (VO2max) was evaluated before training, at the 9(th) and 17(th) session and four days after the final 24(th) training session. In the detraining phase VO2max was evaluated after 12 days and thereafter every second week for eight weeks. Left ventricular echocardiography, carbon monoxide lung diffusion transfer factor, brachial artery flow mediated dilatation and vastus lateralis citrate maximal synthase activity was tested before and after training. The cardiovascular adaptation after HF training was delayed compared to training with MF. Four days after ending training the HF group showed no improvement (+3.0%, p = 0.126), whereas the MF group reached their highest VO2max with a 10.7% improvement (p<0.001: group difference p = 0.035). The HF group reached their highest VO2max (6.1% increase, p = 0.026) twelve days into the detraining period, compared to a concomitant reduction to 7.9% of VO2max (p<0.001) above baseline in the MF group (group difference p = 0.609). Both HF and MF training of high-intensity aerobic exercise improves VO2max. The cardiovascular adaptation following a HF programme of high-intensity exercise is however delayed compared to MF training. ClinicalTrials.gov NCT00733941.

  1. High-Intensity Interval Training Elicits Higher Enjoyment than Moderate Intensity Continuous Exercise

    PubMed Central

    Thum, Jacob S.; Parsons, Gregory; Whittle, Taylor

    2017-01-01

    Exercise adherence is affected by factors including perceptions of enjoyment, time availability, and intrinsic motivation. Approximately 50% of individuals withdraw from an exercise program within the first 6 mo of initiation, citing lack of time as a main influence. Time efficient exercise such as high intensity interval training (HIIT) may provide an alternative to moderate intensity continuous exercise (MICT) to elicit substantial health benefits. This study examined differences in enjoyment, affect, and perceived exertion between MICT and HIIT. Twelve recreationally active men and women (age = 29.5 ± 10.7 yr, VO2max = 41.4 ± 4.1 mL/kg/min, BMI = 23.1 ± 2.1 kg/m2) initially performed a VO2max test on a cycle ergometer to determine appropriate workloads for subsequent exercise bouts. Each subject returned for two additional exercise trials, performing either HIIT (eight 1 min bouts of cycling at 85% maximal workload (Wmax) with 1 min of active recovery between bouts) or MICT (20 min of cycling at 45% Wmax) in randomized order. During exercise, rating of perceived exertion (RPE), affect, and blood lactate concentration (BLa) were measured. Additionally, the Physical Activity Enjoyment Scale (PACES) was completed after exercise. Results showed higher enjoyment (p = 0.013) in response to HIIT (103.8 ± 9.4) versus MICT (84.2 ± 19.1). Eleven of 12 participants (92%) preferred HIIT to MICT. However, affect was lower (p<0.05) and HR, RPE, and BLa were higher (p<0.05) in HIIT versus MICT. Although HIIT is more physically demanding than MICT, individuals report greater enjoyment due to its time efficiency and constantly changing stimulus. Trial Registration: NCT:02981667. PMID:28076352

  2. High-Intensity Interval Training Elicits Higher Enjoyment than Moderate Intensity Continuous Exercise.

    PubMed

    Thum, Jacob S; Parsons, Gregory; Whittle, Taylor; Astorino, Todd A

    2017-01-01

    Exercise adherence is affected by factors including perceptions of enjoyment, time availability, and intrinsic motivation. Approximately 50% of individuals withdraw from an exercise program within the first 6 mo of initiation, citing lack of time as a main influence. Time efficient exercise such as high intensity interval training (HIIT) may provide an alternative to moderate intensity continuous exercise (MICT) to elicit substantial health benefits. This study examined differences in enjoyment, affect, and perceived exertion between MICT and HIIT. Twelve recreationally active men and women (age = 29.5 ± 10.7 yr, VO2max = 41.4 ± 4.1 mL/kg/min, BMI = 23.1 ± 2.1 kg/m2) initially performed a VO2max test on a cycle ergometer to determine appropriate workloads for subsequent exercise bouts. Each subject returned for two additional exercise trials, performing either HIIT (eight 1 min bouts of cycling at 85% maximal workload (Wmax) with 1 min of active recovery between bouts) or MICT (20 min of cycling at 45% Wmax) in randomized order. During exercise, rating of perceived exertion (RPE), affect, and blood lactate concentration (BLa) were measured. Additionally, the Physical Activity Enjoyment Scale (PACES) was completed after exercise. Results showed higher enjoyment (p = 0.013) in response to HIIT (103.8 ± 9.4) versus MICT (84.2 ± 19.1). Eleven of 12 participants (92%) preferred HIIT to MICT. However, affect was lower (p<0.05) and HR, RPE, and BLa were higher (p<0.05) in HIIT versus MICT. Although HIIT is more physically demanding than MICT, individuals report greater enjoyment due to its time efficiency and constantly changing stimulus. NCT:02981667.

  3. Image Quality Assessment of High-Resolution Satellite Images with Mtf-Based Fuzzy Comprehensive Evaluation Method

    NASA Astrophysics Data System (ADS)

    Wu, Z.; Luo, Z.; Zhang, Y.; Guo, F.; He, L.

    2018-04-01

    A Modulation Transfer Function (MTF)-based fuzzy comprehensive evaluation method was proposed in this paper for the purpose of evaluating high-resolution satellite image quality. To establish the factor set, two MTF features and seven radiant features were extracted from the knife-edge region of image patch, which included Nyquist, MTF0.5, entropy, peak signal to noise ratio (PSNR), average difference, edge intensity, average gradient, contrast and ground spatial distance (GSD). After analyzing the statistical distribution of above features, a fuzzy evaluation threshold table and fuzzy evaluation membership functions was established. The experiments for comprehensive quality assessment of different natural and artificial objects was done with GF2 image patches. The results showed that the calibration field image has the highest quality scores. The water image has closest image quality to the calibration field, quality of building image is a little poor than water image, but much higher than farmland image. In order to test the influence of different features on quality evaluation, the experiment with different weights were tested on GF2 and SPOT7 images. The results showed that different weights correspond different evaluating effectiveness. In the case of setting up the weights of edge features and GSD, the image quality of GF2 is better than SPOT7. However, when setting MTF and PSNR as main factor, the image quality of SPOT7 is better than GF2.

  4. Introduction of the identification, situation, background, assessment, recommendations tool to improve the quality of information transfer during medical handover in intensive care.

    PubMed

    Ramasubbu, Benjamin; Stewart, Emma; Spiritoso, Rosalba

    2017-02-01

    To audit the quality and safety of the current doctor-to-doctor handover of patient information in our Cardiothoracic Intensive Care Unit. If deficient, to implement a validated handover tool to improve the quality of the handover process. In Cycle 1 we observed the verbal handover and reviewed the written handover information transferred for 50 consecutive patients in St George's Hospital Cardiothoracic Intensive Care Unit. For each patient's handover, we assessed whether each section of the Identification, Situation, Background, Assessment, Recommendations tool was used on a scale of 0-2. Zero if no information in that category was transferred, one if the information was partially transferred and two if all relevant information was transferred. Each patient's handover received a score from 0 to 10 and thus, each cycle a total score of 0-500. Following the implementation of the Identification, Situation, Background, Assessment, Recommendations handover tool in our Intensive Care Unit in Cycle 2, we re-observed the handover process for another 50 consecutive patients hence, completing the audit cycle. There was a significant difference between the total scores from Cycle 1 and 2 (263/500 versus 457/500, p < 0.001). The median handover score for Cycle 1 was 5/10 (interquartile range 4-6). The median handover score for Cycle 2 was 9/10 (interquartile range 9-10). Patient handover scores increased significantly between Cycle 1 and 2, U = 13.5, p < 0.001. The introduction of a standardised handover template (Identification, Situation, Background, Assessment, Recommendations tool) has improved the quality and safety of the doctor-to-doctor handover of patient information in our Intensive Care Unit.

  5. High-quality cardiopulmonary resuscitation: current and future directions.

    PubMed

    Abella, Benjamin S

    2016-06-01

    Cardiopulmonary resuscitation (CPR) represents the cornerstone of cardiac arrest resuscitation care. Prompt delivery of high-quality CPR can dramatically improve survival outcomes; however, the definitions of optimal CPR have evolved over several decades. The present review will discuss the metrics of CPR delivery, and the evidence supporting the importance of CPR quality to improve clinical outcomes. The introduction of new technologies to quantify metrics of CPR delivery has yielded important insights into CPR quality. Investigations using CPR recording devices have allowed the assessment of specific CPR performance parameters and their relative importance regarding return of spontaneous circulation and survival to hospital discharge. Additional work has suggested new opportunities to measure physiologic markers during CPR and potentially tailor CPR delivery to patient requirements. Through recent laboratory and clinical investigations, a more evidence-based definition of high-quality CPR continues to emerge. Exciting opportunities now exist to study quantitative metrics of CPR and potentially guide resuscitation care in a goal-directed fashion. Concepts of high-quality CPR have also informed new approaches to training and quality improvement efforts for cardiac arrest care.

  6. Effect of moderate- and high-intensity acute exercise on appetite in obese individuals.

    PubMed

    Martins, Catia; Stensvold, Dorthe; Finlayson, Graham; Holst, Jens; Wisloff, Ulrik; Kulseng, Bård; Morgan, Linda; King, Neil A

    2015-01-01

    The effect of acute exercise, and exercise intensity, on appetite control in obese individuals requires further study. The aim of this study was to compare the effects of acute isocaloric bouts (250 kcal) of high-intensity intermittent cycling (HIIC) and moderate-intensity continuous cycling (MICC) or short-duration HIIC (S-HIIC) (125 kcal) and a resting control condition on the appetite hormone responses, subjective feelings of appetite, energy intake (EI), and food reward in overweight/obese individuals. This study is a randomized crossover study on 12 overweight/obese volunteers. Participants were assigned to the control, MICC, HIIC, and S-HIIC conditions, 1 wk apart, in a counterbalanced order. Exercise was performed 1 h after a standard breakfast. An ad libitum test lunch was served 3 h after breakfast. Fasting/postprandial plasma samples of insulin, acylated ghrelin, polypeptide YY3-36, and glucagon-like peptide 1 and subjective feelings of appetite were measured every 30 min for 3 h. Nutrient and taste preferences were measured at the beginning and end of each condition using the Leeds Food Preference Questionnaire. Insulin levels were significantly reduced, and glucagon-like peptide 1 levels significantly increased during all exercise bouts compared with those during rest. Acylated ghrelin plasma levels were lower in the MICC and HIIC, but not in S-HIIC, compared with those in control. There were no significant differences for polypeptide YY3-36 plasma levels, hunger or fullness ratings, EI, or food reward. Our findings suggest that, in overweight/obese individuals, isocaloric bouts of moderate- or high-intensity exercise lead to a similar appetite response. This strengthens previous findings in normal-weight individuals that acute exercise, even at high intensity, does not induce any known physiological adaptation that would lead to increased EI.

  7. Development of high-average-power DPSSL with high beam quality

    NASA Astrophysics Data System (ADS)

    Nakai, Sadao; Kanabe, Tadashi; Kawashima, Toshiyuki; Yamanaka, Masanobu; Izawa, Yasukazu; Nakatuka, Masahiro; Kandasamy, Ranganathan; Kan, Hirofumi; Hiruma, Teruo; Niino, Masayuki

    2000-08-01

    The recent progress of high power diode laser is opening new fields of laser and its application. We are developing high average power diode pumped solid state laser DPSSL for laser fusion power plant, for space propulsion and for various applications in industry. The common features or requirements of our High Average-power Laser for Nuclear-fusion Application (HALNA) are large pulse energy with relatively low repetition of few tens Hz, good beam quality of order of diffraction limit and high efficiency more than 10%. We constructed HALNA 10 (10J X 10 Hz) and tested the performance to clarify the scalability to higher power system. We have obtained in a preliminary experiment a 8.5 J output energy at 0.5 Hz with beam quality of 2 times diffraction limited far-field pattern.

  8. Effects of radiation quality, intensity, and duration on photosynthesis and growth

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bugbee, B.

    1994-12-31

    Differences in radiation quality from the six most common electric lamps have little effect on photosynthetic rate. Radiation quality primarily alters growth because of changes in branching or internode elongation, which change radiation absorption. Growth and yield in wheat appear to be insensitive to radiation quality. Growth and yield in soybeans can be slightly increased under high pressure sodium lamps compared to metal halide lamps, in spite of greatly reduced chlorophyll concentrations under HPS lamps. Daily integrated photosynthetic photon flux (mol m{sup -2} d{sup -1}) most directly determines leaf anatomy and growth. Photosynthetic photon flux levels of 800 {mu}mol m{supmore » -2} s{sup -1} are adequate to simulate field daily-integrated PPF levels for both short and long day plants, but plant canopies can benefit from much higher PPF levels.« less

  9. Effects of radiation quality, intensity, and duration on photosynthesis and growth

    NASA Technical Reports Server (NTRS)

    Bugbee, Bruce

    1994-01-01

    Differences in radiation quality from the six most common electric lamps have little effect on photosynthetic rate. Radiation quality primarily alters growth because of changes in branching or internode elongation, which change radiation absorption. Growth and yield in wheat appear to be insensitive to radiation quality. Growth and yield in soybeans can be slightly increased under high pressure sodium (HPS) lamps compared to metal halide lamps, in spite of greatly reduced chlorophyll concentrations under HPS lamps. Daily integrated photosynthetic photon flux (mol m(exp -2)d(exp -1)) most directly determines leaf anatomy and growth. Photosynthetic photon flux (PPF) levels of 800 (mu)mol m(exp -2)s(exp -1) are adequate to simulate field daily-integrated PPF levels for both short and long day plants, but plant canopies can benefit from much higher PPF levels.

  10. Surface-emitting stimulated emission in high-quality ZnO thin films

    NASA Astrophysics Data System (ADS)

    Zhang, X. Q.; Suemune, Ikuo; Kumano, H.; Wang, J.; Huang, S. H.

    2004-10-01

    High-quality ZnO thin films were grown by plasma-enhanced molecular-beam epitaxy on sapphire substrates. Three excitonic transitions associated with the valence bands A, B, and C were clearly revealed in the reflectance spectrum measured at 33K. This result indicates that the ZnO thin films have the wurtzite crystalline structure. The emission spectra were measured with backscattering geometry at room temperature. When the excitation exceeded a certain value, linewidth narrowing, nonlinear rise of emission intensity, and the shortening of the carrier lifetime were clearly observed and these demonstrate the onset of stimulated emission. Together with the ZnO thickness dependence, we conclude that the observation of a stimulated emission in a direction perpendicular to the film surface is predominantly due to scattering of the in-plane stimulated emission by slightly remaining surface undulations in the ZnO films.

  11. High-intensity compared to moderate-intensity training for exercise initiation, enjoyment, adherence, and intentions: an intervention study.

    PubMed

    Heinrich, Katie M; Patel, Pratik M; O'Neal, Joshua L; Heinrich, Bryan S

    2014-08-03

    Understanding exercise participation for overweight and obese adults is critical for preventing comorbid conditions. Group-based high-intensity functional training (HIFT) provides time-efficient aerobic and resistance exercise at self-selected intensity levels which can increase adherence; behavioral responses to HIFT are unknown. This study examined effects of HIFT as compared to moderate-intensity aerobic and resistance training (ART) on exercise initiation, enjoyment, adherence, and intentions. A stratified, randomized two-group pre-test posttest intervention was conducted for eight weeks in 2012 with analysis in 2013. Participants (n = 23) were stratified by median age (< or ≥ 28) and body mass index (BMI; < or ≥ 30.5). Participants were physically inactive with an average BMI of 31.1 ± 3.5 kg/m2, body fat percentage of 42.0 ± 7.4%, weight of 89.5 ± 14.2 kg, and ages 26.8 ± 5.9 years. Most participants were white, college educated, female, and married/engaged. Both groups completed 3 training sessions per week. The ART group completed 50 minutes of moderate aerobic exercise each session and full-body resistance training on two sessions per week. The HIFT group completed 60-minute sessions of CrossFit™ with actual workouts ranging from 5-30 minutes. Participants completed baseline and posttest questionnaires indicating reasons for exercise initiation (baseline), exercise enjoyment, and exercise intentions (posttest). Adherence was defined as completing 90% of exercise sessions. Daily workout times were recorded. Participants provided mostly intrinsic reasons for exercise initiation. Eighteen participants adhered (ART = 9, 81.8%; HIFT = 9, 75%). HIFT dropouts (p = .012) and ART participants (p = .009) reported lower baseline exercise enjoyment than HIFT participants, although ART participants improved enjoyment at posttest (p = .005). More HIFT participants planned to continue the same exercise than ART participants (p = .002). No significant changes in

  12. Long-term outcome of elderly patients requiring intensive care admission for abdominal pathologies: survival and quality of life.

    PubMed

    Merlani, P; Chenaud, C; Mariotti, N; Ricou, B

    2007-05-01

    Medical developments have allowed the management of patients aged over 70 years with severe abdominal pathologies requiring intensive care unit (ICU) admission. These patients require enhanced life support and present a high ICU mortality. We investigated the outcome and quality of life (QOL) of elderly patients 2 years after their ICU stay for abdominal pathologies. Patients aged 70 years or over with abdominal pathologies, admitted to our ICU over a period of 2 years, were included. Two years following their ICU stay, a letter informed the patients about the present study. Consent to participate was obtained by telephone. QOL was assessed by the Euro-QOL and Short Form-36 questionnaires. Other patient-centered outcomes were evaluated. Overall, 2780 patients were admitted to the ICU during the study period; 141 (5%) patients were eligible; 112 of the 141 (79%) survived their ICU stay, 95 (67%) survived their hospital stay and 52 (37%) were alive 2 years after their ICU stay; 36 of the 52 survivors (69%) answered the questionnaire. Their QOL 2 years after their ICU stay was decreased in comparison with an age-matched population. Eighty-one per cent of patients lived at home and 57% were totally independent. They perceived their ICU stay as positive and 75% stated that they would agree to go through intensive care again. Factors associated with 2-year survival were the absence of co-morbidity, absence of malignancy and a lower Simplified Acute Physiology II score on ICU admission. A high mortality rate and a decrease in QOL were observed in elderly patients with severe abdominal pathologies. Nonetheless, these patients were able to adapt well to their physical disabilities.

  13. Max Tech and Beyond: High-Intensity Discharge Lamps

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scholand, Michael

    High-intensity discharge (HID) lamps are most often found in industrial and commercial applications, and are the light source of choice in street and area lighting, and sports stadium illumination. HID lamps are produced in three types - mercury vapor (MV), high pressure sodium (HPS) and metal halide (MH). Of these, MV and MH are considered white-light sources (although the MV exhibits poor color rendering) and HPS produces a yellow-orange color light. A fourth lamp, low-pressure sodium (LPS), is not a HID lamp by definition, but it is used in similar applications and thus is often grouped with HID lamps. Withmore » the notable exception of MV which is comparatively inefficient and in decline in the US from both a sales and installed stock point of view; HPS, LPS and MH all have efficacies over 100 lumens per watt. The figure below presents the efficacy trends over time for commercially available HID lamps and LPS, starting with MV and LPS in 1930's followed by the development of HPS and MH in the 1960's. In HID lamps, light is generated by creating an electric arc between two electrodes in an arc tube. The particles in the arc are partially ionized, making them electrically conductive, and a light-emitting 'plasma' is created. This arc occurs within the arc tube, which for most HID lamps is enclosed within an evacuated outer bulb that thermally isolates and protects the hot arc tube from the surroundings. Unlike a fluorescent lamp that produces visible light through down-converting UV light with phosphors, the arc itself is the light source in an HID lamp, emitting visible radiation that is characteristic of the elements present in the plasma. Thus, the mixture of elements included in the arc tube is one critical factor determining the quality of the light emitted from the lamp, including its correlated color temperature (CCT) and color rendering index (CRI). Similar to fluorescent lamps, HID lamps require a ballast to start and maintain stable operating

  14. High-quality remote interactive imaging in the operating theatre

    NASA Astrophysics Data System (ADS)

    Grimstead, Ian J.; Avis, Nick J.; Evans, Peter L.; Bocca, Alan

    2009-02-01

    We present a high-quality display system that enables the remote access within an operating theatre of high-end medical imaging and surgical planning software. Currently, surgeons often use printouts from such software for reference during surgery; our system enables surgeons to access and review patient data in a sterile environment, viewing real-time renderings of MRI & CT data as required. Once calibrated, our system displays shades of grey in Operating Room lighting conditions (removing any gamma correction artefacts). Our system does not require any expensive display hardware, is unobtrusive to the remote workstation and works with any application without requiring additional software licenses. To extend the native 256 levels of grey supported by a standard LCD monitor, we have used the concept of "PseudoGrey" where slightly off-white shades of grey are used to extend the intensity range from 256 to 1,785 shades of grey. Remote access is facilitated by a customized version of UltraVNC, which corrects remote shades of grey for display in the Operating Room. The system is successfully deployed at Morriston Hospital, Swansea, UK, and is in daily use during Maxillofacial surgery. More formal user trials and quantitative assessments are being planned for the future.

  15. High-quality substrate for fluorescence enhancement using agarose-coated silica opal film.

    PubMed

    Xu, Ming; Li, Juan; Sun, Liguo; Zhao, Yuanjin; Xie, Zhuoying; Lv, Linli; Zhao, Xiangwei; Xiao, Pengfeng; Hu, Jing; Lv, Mei; Gu, Zhongze

    2010-08-01

    To improve the sensitivity of fluorescence detection in biochip, a new kind of substrates was developed by agarose coating on silica opal film. In this study, silica opal film was fabricated on glass substrate using the vertical deposition technique. It can provide stronger fluorescence signals and thus improve the detection sensitivity. After coating with agarose, the hybrid film could provide a 3D support for immobilizing sample. Comparing with agarose-coated glass substrate, the agarose-coated opal substrates could selectively enhance particular fluorescence signals with high sensitivity when the stop band of the silica opal film in the agarose-coated opal substrate overlapped the fluorescence emission wavelength. A DNA hybridization experiment demonstrated that fluorescence intensity of special type of agarose-coated opal substrates was about four times that of agarose-coated glass substrate. These results indicate that the optimized agarose-coated opal substrate can be used for improving the sensitivity of fluorescence detection with high quality and selectivity.

  16. High-Intensity Interval Cycling Exercise on Wave Reflection and Pulse Wave Velocity.

    PubMed

    Kingsley, J Derek; Tai, Yu Lun; Vaughan, Jeremiah A; Mayo, Xián

    2017-05-01

    Kingsley, JD, Tai, YL, Vaughan, J, and Mayo, X. High-intensity interval cycling exercise on wave reflection and pulse wave velocity. J Strength Cond Res 31(5): 1313-1320, 2017-The purpose of this study was to assess the effects of high-intensity exercise on wave reflection and aortic stiffness. Nine young, healthy men (mean ± SD: age: 22 ± 2 years) participated in the study. The high-intensity interval cycling exercise consisted of 3 sets of Wingate Anaerobic Tests (WATs) with 7.5% of bodyweight as resistance and 2 minutes of rest between each set. Measurements were taken at rest and 1 minute after completion of the WATs. Brachial and aortic blood pressures, as well as wave reflection characteristics, were measured through pulse wave analysis. Aortic stiffness was assessed through carotid-femoral pulse wave velocity (cfPWV). A repeated-measures analysis of variance was used to investigate the effects of the WATs on blood pressure and vascular function across time. There was no change in brachial or aortic systolic pressure from rest to recovery. There was a significant (p ≤ 0.05) decrease in brachial diastolic pressure (rest: 73 ± 6 mm Hg; recovery: 67 ± 9 mm Hg) and aortic diastolic pressure (rest: 75 ± 6 mm Hg; recovery: 70 ± 9 mm Hg) from rest to recovery. In addition, there was no significant change in the augmentation index (rest: 111.4 ± 6.5%; recovery: 109.8 ± 5.8%, p = 0.65) from rest to recovery. However, there was a significant (p ≤ 0.05) increase in the augmentation index normalized at 75 b·min (rest: 3.29 ± 9.82; recovery 21.21 ± 10.87) during recovery compared with rest. There was no change in cfPWV (rest: 5.3 ± 0.8 m·s; recovery: 5.7 ± 0.5m·s; p = 0.09) in response to the WAT. These data demonstrate that high-intensity interval cycling exercise with short rest periods has a nonsignificant effect on vascular function.

  17. A DERATING METHOD FOR THERAPEUTIC APPLICATIONS OF HIGH INTENSITY FOCUSED ULTRASOUND

    PubMed Central

    Bessonova, O.V.; Khokhlova, V.A.; Canney, M.S.; Bailey, M.R.; Crum, L.A.

    2010-01-01

    Current methods of determining high intensity focused ultrasound (HIFU) fields in tissue rely on extrapolation of measurements in water assuming linear wave propagation both in water and in tissue. Neglecting nonlinear propagation effects in the derating process can result in significant errors. In this work, a new method based on scaling the source amplitude is introduced to estimate focal parameters of nonlinear HIFU fields in tissue. Focal values of acoustic field parameters in absorptive tissue are obtained from a numerical solution to a KZK-type equation and are compared to those simulated for propagation in water. Focal waveforms, peak pressures, and intensities are calculated over a wide range of source outputs and linear focusing gains. Our modeling indicates, that for the high gain sources which are typically used in therapeutic medical applications, the focal field parameters derated with our method agree well with numerical simulation in tissue. The feasibility of the derating method is demonstrated experimentally in excised bovine liver tissue. PMID:20582159

  18. A derating method for therapeutic applications of high intensity focused ultrasound

    NASA Astrophysics Data System (ADS)

    Bessonova, O. V.; Khokhlova, V. A.; Canney, M. S.; Bailey, M. R.; Crum, L. A.

    2010-05-01

    Current methods of determining high intensity focused ultrasound (HIFU) fields in tissue rely on extrapolation of measurements in water assuming linear wave propagation both in water and in tissue. Neglecting nonlinear propagation effects in the derating process can result in significant errors. A new method based on scaling the source amplitude is introduced to estimate focal parameters of nonlinear HIFU fields in tissue. Focal values of acoustic field parameters in absorptive tissue are obtained from a numerical solution to a KZK-type equation and are compared to those simulated for propagation in water. Focal wave-forms, peak pressures, and intensities are calculated over a wide range of source outputs and linear focusing gains. Our modeling indicates, that for the high gain sources which are typically used in therapeutic medical applications, the focal field parameters derated with our method agree well with numerical simulation in tissue. The feasibility of the derating method is demonstrated experimentally in excised bovine liver tissue.

  19. A DERATING METHOD FOR THERAPEUTIC APPLICATIONS OF HIGH INTENSITY FOCUSED ULTRASOUND.

    PubMed

    Bessonova, O V; Khokhlova, V A; Canney, M S; Bailey, M R; Crum, L A

    2010-01-01

    Current methods of determining high intensity focused ultrasound (HIFU) fields in tissue rely on extrapolation of measurements in water assuming linear wave propagation both in water and in tissue. Neglecting nonlinear propagation effects in the derating process can result in significant errors. In this work, a new method based on scaling the source amplitude is introduced to estimate focal parameters of nonlinear HIFU fields in tissue. Focal values of acoustic field parameters in absorptive tissue are obtained from a numerical solution to a KZK-type equation and are compared to those simulated for propagation in water. Focal waveforms, peak pressures, and intensities are calculated over a wide range of source outputs and linear focusing gains. Our modeling indicates, that for the high gain sources which are typically used in therapeutic medical applications, the focal field parameters derated with our method agree well with numerical simulation in tissue. The feasibility of the derating method is demonstrated experimentally in excised bovine liver tissue.

  20. What influences acceptability and engagement with a high intensity exercise programme for people with stroke? A qualitative descriptive study.

    PubMed

    Signal, Nada; McPherson, Kathryn; Lewis, Gwyn; Kayes, Nicola; Saywell, Nicola; Mudge, Suzie; Taylor, Denise

    2016-10-14

    Intensity refers to the amount of effort or rate of work undertaken during exercise. People receiving rehabilitation after stroke frequently do not reach the moderate to high intensity exercise recommended to maximise gains. To explore the factors that influence the acceptability of, and engagement with, a high intensity group-based exercise programme for people with stroke. This qualitative descriptive study included 14 people with stroke who had completed a 12-week, high intensity group-based exercise rehabilitation programme. Semi-structured interviews were used to explore the acceptability of high intensity exercise and the barriers and facilitators to engagement. Interviews were recorded, transcribed and analysed using qualitative content analysis. The participants found high intensity exercise rehabilitation acceptable despite describing the exercise intensity as hard and reporting post-exercise fatigue. Participants accepted the fatigue as a normal response to exercise, and it did not appear to negatively influence engagement. The ease with which an individual engaged in high intensity exercise rehabilitation appeared to be mediated by inter-related factors, including: seeing progress, sourcing motivation, working hard, the people involved and the fit with the person and their life. Participants directly related the intensity of their effort to the gains that they made. In this study, people with stroke viewed training at higher intensities as a facilitator, not a barrier, to engagement in exercise rehabilitation. The findings may challenge assumptions about the influence of exercise intensity on engagement.

  1. Plasma Irisin Modestly Increases during Moderate and High-Intensity Afternoon Exercise in Obese Females

    PubMed Central

    Winn, Nathan C.; Grunewald, Zachary I.; Liu, Ying; Heden, Timothy D.; Nyhoff, Lauren M.; Kanaley, Jill A.

    2017-01-01

    Background and Purpose Irisin is an exercise-responsive myokine that has been proposed to exert anti-obesity benefits; yet its response during exercise in obese women is not described. This study characterized plasma irisin levels during a single bout of afternoon isocaloric-exercise of different intensities (moderate- vs high-intensity) in obese females. Methods Eleven obese females participated in 3 randomized study days beginning at 1600h: 1) no exercise (NoEx), 2) moderate exercise (ModEx; 55%VO2max) and 3) high intensity interval exercise (IntEx; 4 min (80%VO2max)/3 min (50% VO2max). Frequent blood samples were analyzed for glucose and lactate (whole-blood), and insulin, c-peptide, glucagon, and irisin (plasma) throughout 190 min of testing. Results Plasma irisin increased above baseline during ModEx and IntEx (P<0.05), but not NoEx (P>0.05). Peak irisin levels during ModEx and IntEx exercise were 11.9± 3.4% and 12.3 ± 4.1% relative to baseline (P<0.05), respectively, with no differences between exercise intensities (P>0.05). Irisin levels remained elevated above resting for 125 minutes post-exercise during ModEx, whereas levels returned to baseline within 15 minutes post-exercise during IntEx. Similarly, no associations were found between plasma irisin levels and circulating lactate, glucose, insulin, c-peptide, or glucagon among study days (P>0.05). However, there was an inverse association between basal irisin and lean mass (r = -0.70, P = 0.01). Conclusion A single bout of moderate and high intensity afternoon exercise induces modest increases in circulating irisin concentrations during exercise; however the regulation post-exercise appears to be dimorphic between exercise intensity in obese females. Future studies are needed to compare morning and afternoon exercise on irisin secretion. PMID:28125733

  2. Blood flow regulation and oxygen uptake during high-intensity forearm exercise.

    PubMed

    Nyberg, S K; Berg, O K; Helgerud, J; Wang, E

    2017-04-01

    The vascular strain is very high during heavy handgrip exercise, but the intensity and kinetics to reach peak blood flow, and peak oxygen uptake, are uncertain. We included 9 young (25 ± 2 yr) healthy males to evaluate blood flow and oxygen uptake responses during continuous dynamic handgrip exercise with increasing intensity. Blood flow was measured using Doppler-ultrasound, and venous blood was drawn from a deep forearm vein to determine arteriovenous oxygen difference (a-vO 2diff ) during 6-min bouts of 60, 80, and 100% of maximal work rate (WR max ), respectively. Blood flow and oxygen uptake increased ( P < 0.05) from 60%WR max [557 ± 177(SD) ml/min; 56.0 ± 21.6 ml/min] to 80%WR max (679 ± 190 ml/min; 70.6 ± 24.8 ml/min), but no change was seen from 80%WR max to 100%WR max Blood velocity (49.5 ± 11.5 to 58.1 ± 11.6 cm/s) and brachial diameter (0.49 ± 0.05 to 0.50 ± 0.06 cm) showed concomitant increases ( P < 0.05) with blood flow from 60% to 80%WR max, whereas no differences were observed in a-vO 2diff Shear rate also increased ( P < 0.05) from 60% (822 ± 196 s -1 ) to 80% (951 ± 234 s -1 ) of WR max The mean response time (MRT) was slower ( P < 0.05) for blood flow (60%WR max 50 ± 22 s; 80%WR max 51 ± 20 s; 100%WR max 51 ± 23 s) than a-vO 2diff (60%WR max 29 ± 9 s; 80%WR max 29 ± 5 s; 100%WR max 20 ± 5 s), but not different from oxygen uptake (60%WR max 44 ± 25 s; 80%WR max 43 ± 14 s; 100%WR max 41 ± 32 s). No differences were observed in MRT for blood flow or oxygen uptake with increased exercise intensity. In conclusion, when approaching maximal intensity, oxygen uptake appeared to reach a critical level at ~80% of WR max and be regulated by blood flow. This implies that high, but not maximal, exercise intensity may be an optimal stimulus for shear stress-induced small muscle mass training adaptations. NEW & NOTEWORTHY This study evaluated blood flow regulation and oxygen uptake during small muscle mass forearm exercise with high to

  3. Experimental evidence of space charge driven resonances in high intensity linear accelerators

    DOE PAGES

    Jeon, Dong -O

    2016-01-12

    In the construction of high intensity accelerators, it is the utmost goal to minimize the beam loss by avoiding or minimizing contributions of various halo formation mechanisms. As a halo formation mechanism, space charge driven resonances are well known for circular accelerators. However, the recent finding showed that even in linear accelerators the space charge potential can excite the 4σ = 360° fourth order resonance [D. Jeon et al., Phys. Rev. ST Accel. Beams 12, 054204 (2009)]. This study increased the interests in space charge driven resonances of linear accelerators. Experimental studies of the space charge driven resonances of highmore » intensity linear accelerators are rare as opposed to the multitude of simulation studies. This paper presents an experimental evidence of the space charge driven 4σ ¼ 360° resonance and the 2σ x(y) – 2σ z = 0 resonance of a high intensity linear accelerator through beam profile measurements from multiple wire-scanners. Moreover, measured beam profiles agree well with the characteristics of the space charge driven 4σ = 360° resonance and the 2σ x(y) – 2σ z = 0 resonance that are predicted by the simulation.« less

  4. High-speed transport-of-intensity phase microscopy with an electrically tunable lens.

    PubMed

    Zuo, Chao; Chen, Qian; Qu, Weijuan; Asundi, Anand

    2013-10-07

    We present a high-speed transport-of-intensity equation (TIE) quantitative phase microscopy technique, named TL-TIE, by combining an electrically tunable lens with a conventional transmission microscope. This permits the specimen at different focus position to be imaged in rapid succession, with constant magnification and no physically moving parts. The simplified image stack collection significantly reduces the acquisition time, allows for the diffraction-limited through-focus intensity stack collection at 15 frames per second, making dynamic TIE phase imaging possible. The technique is demonstrated by profiling of microlens array using optimal frequency selection scheme, and time-lapse imaging of live breast cancer cells by inversion the defocused phase optical transfer function to correct the phase blurring in traditional TIE. Experimental results illustrate its outstanding capability of the technique for quantitative phase imaging, through a simple, non-interferometric, high-speed, high-resolution, and unwrapping-free approach with prosperous applications in micro-optics, life sciences and bio-photonics.

  5. Implementing Pay-for-Performance in the Neonatal Intensive Care Unit

    PubMed Central

    Profit, Jochen; Zupancic, John A. F.; Gould, Jeffrey B.; Petersen, Laura A.

    2011-01-01

    Pay-for-performance initiatives in medicine are proliferating rapidly. Neonatal intensive care is a likely target for these efforts because of the high cost, available databases, and relative strength of evidence for at least some measures of quality. Pay-for-performance may improve patient care but requires valid measurements of quality to ensure that financial incentives truly support superior performance. Given the existing uncertainty with respect to both the effectiveness of pay-for-performance and the state of quality measurement science, experimentation with pay-for-performance initiatives should proceed with caution and in controlled settings. In this article, we describe approaches to measuring quality and implementing pay-for-performance in the NICU setting. PMID:17473099

  6. High-intensity focused ultrasound (HIFU) array system for image-guided ablative therapy (IGAT)

    NASA Astrophysics Data System (ADS)

    Kaczkowski, Peter J.; Keilman, George W.; Cunitz, Bryan W.; Martin, Roy W.; Vaezy, Shahram; Crum, Lawrence A.

    2003-06-01

    Recent interest in using High Intensity Focused Ultrasound (HIFU) for surgical applications such as hemostasis and tissue necrosis has stimulated the development of image-guided systems for non-invasive HIFU therapy. Seeking an all-ultrasound therapeutic modality, we have developed a clinical HIFU system comprising an integrated applicator that permits precisely registered HIFU therapy delivery and high quality ultrasound imaging using two separate arrays, a multi-channel signal generator and RF amplifier system, and a software program that provides the clinician with a graphical overlay of the ultrasound image and therapeutic protocol controls. Electronic phasing of a 32 element 2 MHz HIFU annular array allows adjusting the focus within the range of about 4 to 12 cm from the face. A central opening in the HIFU transducer permits mounting a commercial medical imaging scanhead (ATL P7-4) that is held in place within a special housing. This mechanical fixture ensures precise coaxial registration between the HIFU transducer and the image plane of the imaging probe. Recent enhancements include development of an acoustic lens using numerical simulations for use with a 5-element array. Our image-guided therapy system is very flexible and enables exploration of a variety of new HIFU therapy delivery and monitoring approaches in the search for safe, effective, and efficient treatment protocols.

  7. Fatigue in Intensive Care Nurses and Related Factors.

    PubMed

    Çelik, Sevim; Taşdemir, Nurten; Kurt, Aylin; İlgezdi, Ebru; Kubalas, Özge

    2017-10-01

    Fatigue negatively affects the performance of intensive care nurses. Factors contributing to the fatigue experienced by nurses include lifestyle, psychological status, work organization and sleep problems. To determine the level of fatigue among nurses working in intensive care units and the related factors. This descriptive study was conducted with 102 nurses working in intensive care units in the West Black Sea Region of Turkey. Data were collected between February and May 2014 using a personal information form, the Visual Analogue Scale for Fatigue (VAS-F), the Hospital Anxiety and Depression Scale and the Pittsburg Sleep Quality Index. The intensive care nurses in the study were found to be experiencing fatigue. Significant correlations were observed between scores on the VAS-F Fatigue and anxiety (p=0.01), depression (p=0.002), and sleep quality (p<0.001). Anxiety, depression and quality of sleep were significantly affected by the intensive care nurses' levels of fatigue. These results can be of benefit in taking measures which may be used to reduce fatigue in nurses, especially the fatigue related to work organization and social life.

  8. Effects of myofascial release after high-intensity exercise: a randomized clinical trial.

    PubMed

    Arroyo-Morales, Manuel; Olea, Nicolas; Martinez, Manuel; Moreno-Lorenzo, Carmen; Díaz-Rodríguez, Lourdes; Hidalgo-Lozano, Amparo

    2008-03-01

    The usefulness of massage as a recovery method after high-intensity exercise has yet to be established. We aimed to investigate the effects of whole-body massage on heart rate variability (HRV) and blood pressure (BP) after repeated high-intensity cycling exercise under controlled and standardized pretest conditions. The study included 62 healthy active individuals. After baseline measurements, the subjects performed standardized warm-up exercises followed by three 30-second Wingate tests. After completing the exercise protocol, the subjects were randomly assigned to a massage (myofascial release) or placebo (sham treatment with disconnected ultrasound and magnetotherapy equipment) group for a 40-minute recovery period. Holter recording and BP measurements were taken after exercise protocol and after the intervention. After the exercise protocol, both groups showed a significant decrease in normal-to-normal interval, HRV index, diastolic BP (P > .001), and low-frequency domain values (P = .006). After the recovery period, HRV index (P = .42) and high-frequency (HF) (P = .94) values were similar to baseline levels in the massage group, whereas the HRV index tended (P = .05) to be lower and the HF was significantly (P < .01) lower vs baseline values in the placebo group, which also showed a tendency (P = .06) for HF to be lower than after the exercise. Likewise, diastolic BP returned to baseline levels in the massage group (P = .45) but remained lower in the placebo group (P = .02). Myofascial release massage favors the recovery of HRV and diastolic BP after high-intensity exercise (3 Wingate tests) to preexercise levels.

  9. Reliability of a Novel High Intensity One Leg Dynamic Exercise Protocol to Measure Muscle Endurance

    PubMed Central

    Lepers, Romuald; Marcora, Samuele M.

    2016-01-01

    We recently developed a high intensity one leg dynamic exercise (OLDE) protocol to measure muscle endurance and investigate the central and peripheral mechanisms of muscle fatigue. The aims of the present study were to establish the reliability of this novel protocol and describe the isokinetic muscle fatigue induced by high intensity OLDE and its recovery. Eight subjects performed the OLDE protocol (time to exhaustion test of the right leg at 85% of peak power output) three times over a week period. Isokinetic maximal voluntary contraction torque at 60 (MVC60), 100 (MVC100) and 140 (MVC140) deg/s was measured pre-exercise, shortly after exhaustion (13 ± 4 s), 20 s (P20) and 40 s (P40) post-exercise. Electromyographic (EMG) signal was analyzed via the root mean square (RMS) for all three superficial knee extensors. Mean time to exhaustion was 5.96 ± 1.40 min, coefficient of variation was 8.42 ± 6.24%, typical error of measurement was 0.30 min and intraclass correlation was 0.795. MVC torque decreased shortly after exhaustion for all angular velocities (all P < 0.001). MVC60 and MVC100 recovered between P20 (P < 0.05) and exhaustion and then plateaued. MVC140 recovered only at P40 (P < 0.05). High intensity OLDE did not alter maximal EMG RMS of the three superficial knee extensors during MVC. The results of this study demonstrate that this novel high intensity OLDE protocol could be reliably used to measure muscle endurance, and that muscle fatigue induced by high intensity OLDE should be examined within ~ 30 s following exhaustion. PMID:27706196

  10. Long-term high-intensity sound stimulation inhibits h current (Ih ) in CA1 pyramidal neurons.

    PubMed

    Cunha, A O S; Ceballos, C C; de Deus, J L; Leão, R M

    2018-05-19

    Afferent neurotransmission to hippocampal pyramidal cells can lead to long-term changes to their intrinsic membrane properties and affect many ion currents. One of the most plastic neuronal currents is the hyperpolarization activated cationic current (I h ), which changes in CA1 pyramidal cells in response to many types of physiological and pathological processes, including auditory stimulation. Recently we demonstrated that long-term potentiation (LTP) in rat hippocampal Schaffer-CA1 synapses is depressed by high-intensity sound stimulation. Here we investigated if a long-term high-intensity sound stimulation could affect intrinsic membrane properties of rat CA1 pyramidal neurons. Our results showed that I h is depressed by long-term high intensity sound exposure (1 minute of 110 dB sound, applied two times per day for 10 days). This resulted in a decreased resting membrane potential, increased membrane input resistance and time constant, and decreased action potential threshold. In addition, CA1 pyramidal neurons from sound-exposed animals fired more action potentials than neurons from control animals; However, this effect was not caused by a decreased I h . Interestingly, a single episode (1 minute) of 110 dB sound stimulation which also inhibits hippocampal LTP did not affect I h and firing in pyramidal neurons, suggesting that effects on I h are long-term responses to high intensity sound exposure. Our results show that prolonged exposure to high-intensity sound affects intrinsic membrane properties of hippocampal pyramidal neurons, mainly by decreasing the amplitude of I h . This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  11. High-intensity interval training has positive effects on performance in ice hockey players.

    PubMed

    Naimo, M A; de Souza, E O; Wilson, J M; Carpenter, A L; Gilchrist, P; Lowery, R P; Averbuch, B; White, T M; Joy, J

    2015-01-01

    In spite of the well-known benefits that have been shown, few studies have looked at the practical applications of high-intensity interval training (HIIT) on athletic performance. This study investigated the effects of a HIIT program compared to traditional continuous endurance exercise training. 24 hockey players were randomly assigned to either a continuous or high-intensity interval group during a 4-week training program. The interval group (IG) was involved in a periodized HIIT program. The continuous group (CG) performed moderate intensity cycling for 45-60 min at an intensity that was 65% of their calculated heart rate reserve. Body composition, muscle thickness, anaerobic power, and on-ice measures were assessed pre- and post-training. Muscle thickness was significantly greater in IG (p=0.01) when compared to CG. The IG had greater values for both ∆ peak power (p<0.003) and ∆ mean power (p<0.02). Additionally, IG demonstrated a faster ∆ sprint (p<0.02) and a trend (p=0.08) for faster ∆ endurance test time to completion for IG. These results indicate that hockey players may utilize short-term HIIT to elicit positive effects in muscle thickness, power and on-ice performance. © Georg Thieme Verlag KG Stuttgart · New York.

  12. EFFECTS OF AROMATHERAPY MASSAGE ON THE SLEEP QUALITY AND PHYSIOLOGICAL PARAMETERS OF PATIENTS IN A SURGICAL INTENSIVE CARE UNIT.

    PubMed

    Özlü, Zeynep Karaman; Bilican, Pınar

    2017-01-01

    Surgical pain is experienced by inpatients with clinical, disease-related concerns, unknown encounters after surgery, quality of sleep, restrictions in position after surgery is known to be serious. The study was conducted to determine the effect of aromatherapy massage on quality of sleep and physiological parameters in surgical intensive care patients. This is an experimental study. The sample of this study consisted of 60 patients who were divided into two groups as experimental group and control group including 30 patients in each one. The participants were postoperative patients, absent complications, who were unconscious and extubated. A data collection form on personal characteristics of the patients, a registration form on their physical parameters and the Richards-Campbell Sleep Scale (RCSQ) were used to collect the data of the study. The Richards-Campbell Sleep Scale indicated that while the experimental group had a mean score of 53.80 ± 13.20, the control group had a mean score of 29.08 ± 9.71 and there was a statistically significant difference between mean scores of the groups. In a comparison of physiologic parameters, only diastolic blood pressure measuring between parameters in favor of an assembly as a statistically significant difference was detected. Results of the study showed that aromatherapy massage enhanced the sleep quality of patients in a surgical intensive care unit and resulted in some positive changes in their physiological parameters.

  13. Intensive case management for high-risk patients with first-episode psychosis: service model and outcomes.

    PubMed

    Brewer, Warrick J; Lambert, Timothy J; Witt, Katrina; Dileo, John; Duff, Cameron; Crlenjak, Carol; McGorry, Patrick D; Murphy, Brendan P

    2015-01-01

    The first episode of psychosis is a crucial period when early intervention can alter the trajectory of the young person's ongoing mental health and general functioning. After an investigation into completed suicides in the Early Psychosis Prevention and Intervention Centre (EPPIC) programme, the intensive case management subprogramme was developed in 2003 to provide assertive outreach to young people having a first episode of psychosis who are at high risk owing to risk to self or others, disengagement, or suboptimal recovery. We report intensive case management model development, characterise the target cohort, and report on outcomes compared with EPPIC treatment as usual. Inclusion criteria, staff support, referral pathways, clinical review processes, models of engagement and care, and risk management protocols are described. We compared 120 consecutive referrals with 50 EPPIC treatment as usual patients (age 15-24 years) in a naturalistic stratified quasi-experimental real-world design. Key performance indicators of service use plus engagement and suicide attempts were compared between EPPIC treatment as usual and intensive case management, and psychosocial and clinical measures were compared between intensive case management referral and discharge. Referrals were predominately unemployed males with low levels of functioning and educational attainment. They were characterised by a family history of mental illness, migration and early separation, with substantial trauma, history of violence, and forensic attention. Intensive case management improved psychopathology and psychosocial outcomes in high-risk patients and reduced risk ratings, admissions, bed days, and crisis contacts. Characterisation of intensive case management patients validated the clinical research focus and identified a first episode of psychosis high-risk subgroup. In a real-world study, implementation of an intensive case management stream within a well-established first episode of psychosis

  14. High Intensity Organic Light-emitting Diodes

    NASA Astrophysics Data System (ADS)

    Qi, Xiangfei

    This thesis is dedicated to the fabrication, modeling, and characterization to achieve high efficiency organic light-emitting diodes (OLEDs) for illumination applications. Compared to conventional lighting sources, OLEDs enabled the direct conversion of electrical energy into light emission and have intrigued the world's lighting designers with the long-lasting, highly efficient illumination. We begin with a brief overview of organic technology, from basic organic semiconductor physics, to its application in optoelectronics, i.e. light-emitting diodes, photovoltaics, photodetectors and thin-film transistors. Due to the importance of phosphorescent materials, we will focus on the photophysics of metal complexes that is central to high efficiency OLED technology, followed by a transient study to examine the radiative decay dynamics in a series of phosphorescent platinum binuclear complexes. The major theme of this thesis is the design and optimization of a novel architecture where individual red, green and blue phosphorescent OLEDs are vertically stacked and electrically interconnected by the compound charge generation layers. We modeled carrier generation from the metal-oxide/doped organic interface based on a thermally assisted tunneling mechanism. The model provides insights to the optimization of a stacked OLED from both electrical and optical point of view. To realize the high intensity white lighting source, the efficient removal of heat is of a particular concern, especially in large-area devices. A fundamental transfer matrix analysis is introduced to predict the thermal properties in the devices. The analysis employs Laplace transforms to determine the response of the system to the combined effects of conduction, convection, and radiation. This perspective of constructing transmission matrices greatly facilitates the calculation of transient coupled heat transfer in a general multi-layer composite. It converts differential equations to algebraic forms, and

  15. High quality factor, fully switchable terahertz superconducting metasurface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scalari, G., E-mail: scalari@phys.ethz.ch; Maissen, C.; Faist, J.

    2014-12-29

    We present a complementary THz metasurface realised with Niobium thin film which displays a quality factor Q = 54 and a fully switchable behaviour as a function of the temperature. The switching behaviour and the high quality factor are due to a careful design of the metasurface aimed at maximising the ohmic losses when the Nb is above the critical temperature and minimising the radiative coupling. The superconductor allows the operation of the cavity with high Q and the use of inductive elements with a high aspect ratio. Comparison with three dimensional finite element simulations highlights the crucial role of the inductivemore » elements and of the kinetic inductance of the Cooper pairs in achieving the high quality factor and the high field enhancement.« less

  16. High Intensity Proton Accelerator Project in Japan (J-PARC).

    PubMed

    Tanaka, Shun-ichi

    2005-01-01

    The High Intensity Proton Accelerator Project, named as J-PARC, was started on 1 April 2001 at Tokai-site of JAERI. The accelerator complex of J-PARC consists of three accelerators: 400 MeV Linac, 3 GeV rapid cycle synchrotron and 50 GeV synchrotron; and four major experimental facilities: Material and Life Science Facility, Nuclear and Particle Physics Facility, Nuclear Transmutation Experiment Facility and Neutrino Facility. The outline of the J-PARC is presented with the current status of construction.

  17. Use of high intensity reflective materials in highway signing : a literature review.

    DOT National Transportation Integrated Search

    1973-01-01

    This literature review summarizes the research findings relative to the performance of high intensity (encapsulated lens) reflective sheeting. The study reveals that the brightness and durability of the encapsulated lens material are superior to thos...

  18. High-intensity focused ultrasound treatment for intra-abdominal desmoid tumors: a report of four cases.

    PubMed

    Shi, Yulan; Huang, Yanqin; Zhou, Meiqi; Ying, Xiao; Hu, Xiaoye

    2016-04-01

    Desmoid tumors are rare clonal fibroblastic proliferations that can arise at abdominal or extra-abdominal sites. Complete surgical resection is the primary treatment for resectable desmoid tumors, but a high rate of local recurrence has been reported even after complete resection. For patients with a recurrent tumor, the goals of treatment are to control the recurrence, maintain quality of life, and prolong survival. Radiofrequency ablation, radiotherapy, chemotherapy, and other medical therapies can be used as alternative methods, but there are considerable controversies over the roles of these methods in the management of desmoid tumors. High-intensity focused ultrasound (HIFU) is a minimally invasive and effective method for treatment of solid tumors. We used HIFU to treat four patients with intra-abdominal desmoid tumors from June 2011 to September 2013. Post-procedural pain was seen in all patients. One patient had an intra-abdominal abscess and another suffered a slight injury to the femoral nerve. The patients were followed up for 19-46 months (mean 34 months) until April 2015. The tumor in one patient disappeared, and no tumor progression was observed in the other patients.

  19. Transmission of laser pulses with high output beam quality using step-index fibers having large cladding

    DOEpatents

    Yalin, Azer P; Joshi, Sachin

    2014-06-03

    An apparatus and method for transmission of laser pulses with high output beam quality using large core step-index silica optical fibers having thick cladding, are described. The thick cladding suppresses diffusion of modal power to higher order modes at the core-cladding interface, thereby enabling higher beam quality, M.sup.2, than are observed for large core, thin cladding optical fibers. For a given NA and core size, the thicker the cladding, the better the output beam quality. Mode coupling coefficients, D, has been found to scale approximately as the inverse square of the cladding dimension and the inverse square root of the wavelength. Output from a 2 m long silica optical fiber having a 100 .mu.m core and a 660 .mu.m cladding was found to be close to single mode, with an M.sup.2=1.6. Another thick cladding fiber (400 .mu.m core and 720 .mu.m clad) was used to transmit 1064 nm pulses of nanosecond duration with high beam quality to form gas sparks at the focused output (focused intensity of >100 GW/cm.sup.2), wherein the energy in the core was <6 mJ, and the duration of the laser pulses was about 6 ns. Extending the pulse duration provided the ability to increase the delivered pulse energy (>20 mJ delivered for 50 ns pulses) without damaging the silica fiber.

  20. Space charge problems in high intensity RFQs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weiss, M.

    1996-06-01

    Measurements were made to check the performance of the CERN high intensity RFQs (RFQ2A and RFQ2B) and assess the validity of the design approach; the study of space charge effects was undertaken in this context. RFQ2A and RFQ2B are 200 mA, 750 keV proton accelerators, operating at 202.56 MHz. Since the beginning of 1993, RFQ2B serves as injector to the CERN 50 MeV Alvarez linac (Linac 2). In 1992, both RFQs were on the test stand to undergo a series of beam measurements, which were compared with computations. The studies concerning the RFQ2A were more detailed and they are reportedmore » in this paper. {copyright} {ital 1996 American Institute of Physics.}« less

  1. High-intensity statin therapy and regression of coronary atherosclerosis in patients with diabetes mellitus.

    PubMed

    Athyros, Vasilios G; Katsiki, Niki; Karagiannis, Asterios; Mikhailidis, Dimitri P

    2015-01-01

    Recommended low-density lipoprotein cholesterol (LDL-C) levels for patients with documented cardiovascular disease (CVD) are <100mg/dL (2.6mmol/l) with further reduction to <70mg/dL (1.8mmol/l) for higher-risk patients. High-intensity statin treatment may halt the progression as well as stabilize and induce regression of coronary atheromatous plaques while lowering CVD event rates. Diabetes mellitus (DM) is a major negative determinant of coronary artery plaque regression during statin therapy. However, regression of coronary atherosclerosis in DM patients is feasible to the same degree as in those without DM when very low LDL-C values (<70mg/dL; 1.8mmol/l) are achieved with high intensity statin treatment. The recent 2013 American College of Cardiology/American Heart Association (ACC/AHA) Guidelines on the Treatment of Blood Cholesterol to Reduce Atherosclerotic Cardiovascular Risk in Adults suggest to abandon specific LDL-C treatment targets. This strategy may deprive high risk patients, such as those with DM, from very high intensity statin treatment or drug combinations aiming to achieve very low LDL-C levels in order to reduce clinical events. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Report of the Snowmass M6 Working Group on high intensity proton sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weiren Chou and J. Wei

    The U.S. high-energy physics program needs an intense proton source, a 1-4 MW Proton Driver (PD), by the end of this decade. This machine will serve as a stand-alone facility that will provide neutrino superbeams and other high intensity secondary beams such as kaons, muons, neutrons, and anti-protons (cf. E1 and E5 group reports) and also serve as the first stage of a neutrino factory (cf. M1 group report). It can also be a high brightness source for a VLHC. Based on present accelerator technology and project construction experience, it is both feasible and cost-effective to construct a 1-4 MWmore » Proton Driver. Two recent PD design studies have been made, one at FNAL and the other at the BNL. Both designed PD's for 1 MW proton beams at a cost of about U.S. $200M (excluding contingency and overhead) and both designs were upgradeable to 4 MW. An international collaboration between FNAL, BNL and KEK on high intensity proton facilities is addressing a number of key design issues. The superconducting (sc) RF cavities, cryogenics, and RF controls developed for the SNS can be directly adopted to save R&D efforts, cost, and schedule. PD studies are also actively being pursued at Europe and Japan.« less

  3. High Intensity Laser Therapy (HILT) versus TENS and NSAIDs in low back pain: clinical study

    NASA Astrophysics Data System (ADS)

    Zati, Allesandro; Fortuna, Damiano; Valent, A.; Filippi, M. V.; Bilotta, Teresa W.

    2004-09-01

    Low back pain, caused by lumbar disc herniation, is prevalently treated with a conservative approach. In this study we valued the efficacy of High Intensity Laser Therapy (HILT), compared with accepted therapies such as TENS and NSAIDs. Laser therapy obtained similar results in the short term, but better clinical effect over time than TENS and NSAIDs. In conclusion high intensity laser therapy appears to be a interesting new treatment, worthy of further research.

  4. Liquid Metal Engineering by Application of Intensive Melt Shearing

    NASA Astrophysics Data System (ADS)

    Patel, Jayesh; Zuo, Yubo; Fan, Zhongyun

    In all casting processes, liquid metal treatment is an essential step in order to produce high quality cast products. A new liquid metal treatment technology has been developed which comprises of a rotor/stator set-up that delivers high shear rate to the liquid melt. It generates macro-flow in a volume of melt for distributive mixing and intensive shearing for dispersive mixing. The high shear device exhibits significantly enhanced kinetics for phase transformations, uniform dispersion, distribution and size reduction of solid particles and gas bubbles, improved homogenisation of chemical composition and temperature fields and also forced wetting of usually difficult-to-wet solid particles in the liquid metal. Hence, it can benefit various casting processes to produce high quality cast products with refined microstructure and enhanced mechanical properties. Here, we report an overview on the application of the new high shear technology to the processing of light metal alloys.

  5. Silicon solar cells as a high-solar-intensity radiometer

    NASA Technical Reports Server (NTRS)

    Spisz, E. W.; Robson, R. R.

    1971-01-01

    The characteristics of a conventional, 1- by 2-cm, N/P, gridded silicon solar cell when used as a radiometer have been determined for solar intensity levels to 2800 mW/sq cm (20 solar constants). The short-circuit current was proportional to the radiant intensity for levels only to 700 mW/sq cm (5 solar constants). For intensity levels greater than 700 mW/sq cm, it was necessary to operate the cell in a photoconductive mode in order to obtain a linear relation between the measured current and the radiant intensity. When the solar cell was biased with a reverse voltage of -1 V, the measured current and radiant intensity were linearly related over the complete intensity range from 100 to 2800 mW/sq cm.

  6. Potential Universal Application of High-intensity Interval Training from Athletes and Sports Lovers to Patients.

    PubMed

    Azuma, Koichiro; Matsumoto, Hideo

    2017-06-25

    Recently, high-intensity interval training (HIIT) has received much attention as a promising exercise option not only to improve aerobic fitness, but also to prevent and improve lifestyle-related diseases. Epidemiological studies have shown that the exercise volume, as determined by the product of exercise intensity, duration, and frequency, has been shown to be important for improvements in muscle mitochondrial activity and subsequent improvements in aerobic fitness, insulin sensitivity, and metabolic variables. Therefore, continuous moderate-intensity training has been widely recommended. On the other hand, the main contributor of HIIT to improvements in aerobic fitness and metabolic variables is its high-intensity nature, and many recent studies have shown results favoring HIIT when compared with conventional continuous training, despite its shorter exercise duration and smaller exercise volume. In this review, we aim to show the possible universal application of HIIT in a hospital setting, where athletes, sports lovers, and patients have sought medical advice and have the opportunity to undergo detailed evaluations, including an exercise stress test. For athletes, HIIT is mandatory to achieve further improvements in aerobic fitness. For patients, though higher levels of motivation and careful evaluation are required, the time constraints of HIIT are smaller and both aerobic and resistance training can be expected to yield favorable results because of the high-intensity nature of HIIT.

  7. Non-Thermal High-Intensity Focused Ultrasound for Breast Cancer Therapy

    DTIC Science & Technology

    2013-07-01

    ultrasound for breast cancer therapy PRINCIPAL INVESTIGATOR: Chang Ming (Charlie) Ma, Ph.D...TITLE AND SUBTITLE 5a. CONTRACT NUMBER Non-thermal high-intensity focused ultrasound for breast cancer therapy 5b. GRANT NUMBER W81XWH-11-1-0341...treatment systems for small animal models. Advanced imaging systems will be required to determine the gross tumor volume, to plan the HIFU treatment, to

  8. 75 FR 52780 - Designation of Nine Counties as High Intensity Drug Trafficking Areas

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-27

    ... EXECUTIVE OFFICE OF THE PRESIDENT Office of National Drug Control Policy Designation of Nine Counties as High Intensity Drug Trafficking Areas ACTION: Notice. SUMMARY: The Director of the Office of National Drug Control Policy designated nine additional counties as High Drug Trafficking Areas pursuant to...

  9. 75 FR 21368 - Designation of Five Counties as High Intensity Drug Trafficking Areas

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-23

    ... EXECUTIVE OFFICE OF THE PRESIDENT Office of National Drug Control Policy Designation of Five Counties as High Intensity Drug Trafficking Areas ACTION: Notice. SUMMARY: The Director of the Office of National Drug Control Policy designated five additional counties as High Drug Trafficking Areas pursuant to...

  10. High-Intensity Locomotor Exercise Increases Brain-Derived Neurotrophic Factor in Individuals with Incomplete Spinal Cord Injury.

    PubMed

    Leech, Kristan A; Hornby, T George

    2017-03-15

    High-intensity locomotor exercise is suggested to contribute to improved recovery of locomotor function after neurological injury. This may be secondary to exercise-intensity-dependent increases in neurotrophin expression demonstrated previously in control subjects. However, rigorous examination of intensity-dependent changes in neurotrophin levels is lacking in individuals with motor incomplete spinal cord injury (SCI). Therefore, the primary aim of this study was to evaluate the effect of locomotor exercise intensity on peripheral levels of brain-derived neurotrophic factor (BDNF) in individuals with incomplete SCI. We also explored the impact of the Val66Met single-nucleotide polymorphism (SNP) on the BDNF gene on intensity-dependent changes. Serum concentrations of BDNF and insulin-like growth factor-1 (IGF-1), as well as measures of cardiorespiratory dynamics, were evaluated across different levels of exercise intensity achieved during a graded-intensity, locomotor exercise paradigm in 11 individuals with incomplete SCI. Our results demonstrate a significant increase in serum BDNF at high, as compared to moderate, exercise intensities (p = 0.01) and 15 and 30 min post-exercise (p < 0.01 for both), with comparison to changes at low intensity approaching significance (p = 0.05). Serum IGF-1 demonstrated no intensity-dependent changes. Significant correlations were observed between changes in BDNF and specific indicators of exercise intensity (e.g., rating of perceived exertion; R = 0.43; p = 0.02). Additionally, the data suggest that Val66Met SNP carriers may not exhibit intensity-dependent changes in serum BDNF concentration. Given the known role of BDNF in experience-dependent neuroplasticity, these preliminary results suggest that exercise intensity modulates serum BDNF concentrations and may be an important parameter of physical rehabilitation interventions after neurological injury.

  11. Physiological responses of young thoroughbred horses to intermittent high-intensity treadmill training

    PubMed Central

    2013-01-01

    Background Training of young Thoroughbred horses must balance development of cardiopulmonary function and aerobic capacity with loading of the musculoskeletal system that can potentially cause structural damage and/or lameness. High-speed equine treadmills are sometimes used to supplement exercise on a track in the training of young Thoroughbreds because the horse can run at high speeds but without the added weight of a rider. We tested the hypothesis that intermittent high-intensity exercise on a treadmill of young Thoroughbred horses entering training can enhance development of aerobic capacity (Vo2max) and running performance more than conventional training under saddle, and do so without causing lameness. Results Twelve yearling Thoroughbreds trained for 8 months with conventional riding (C) only, conventional riding plus a short (2 month, S) interval of once-per-week high-intensity treadmill exercise, or a long (8 month, L) interval of once-per-week high-intensity treadmill exercise. Three treadmill exercise tests evaluated Vo2max, oxygen transport and running performance variables in June of the yearling year (only for L), October of the yearling year and April of the 2-year-old year. No horses experienced lameness during the study. Aerobic capacity increased in all groups after training. In both October and April, Vo2max in L was higher than in C, but did not differ between L and S or S and C. Running speeds eliciting Vo2max also increased in all groups after training, with S (809 ± 3 m/s) and L (804 ± 9 m/s) higher than C (764 ± 27 m/s). Maximum heart rate decreased for all groups after training. Hematocrit and hemoglobin concentration increased for L throughout training. Conclusions Young Thoroughbred horses can increase aerobic capacity and running performance more than by strictly using track training under saddle with the addition of intermittent high-intensity treadmill exercise, and they can do so without experiencing lameness

  12. Optical Fiber High Temperature Sensor Instrumentation for Energy Intensive Industries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cooper, Kristie L.; Wang, Anbo; Pickrell, Gary R.

    2006-11-14

    This report summarizes technical progress during the program “Optical Fiber High Temperature Sensor Instrumentation for Energy Intensive Industries”, performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The objective of this program was to use technology recently invented at Virginia Tech to develop and demonstrate the application of self-calibrating optical fiber temperature and pressure sensors to several key energy-intensive industries where conventional, commercially available sensors exhibit greatly abbreviated lifetimes due primarily to environmental degradation. A number of significant technologies were developed under this program, including • a laser bonded silicamore » high temperature fiber sensor with a high temperature capability up to 700°C and a frequency response up to 150 kHz, • the world’s smallest fiber Fabry-Perot high temperature pressure sensor (125 x 20 μm) with 700°C capability, • UV-induced intrinsic Fabry-Perot interferometric sensors for distributed measurement, • a single crystal sapphire fiber-based sensor with a temperature capability up to 1600°C. These technologies have been well demonstrated and laboratory tested. Our work plan included conducting major field tests of these technologies at EPRI, Corning, Pratt & Whitney, and Global Energy; field validation of the technology is critical to ensuring its usefulness to U.S. industries. Unfortunately, due to budget cuts, DOE was unable to follow through with its funding commitment to support Energy Efficiency Science Initiative projects and this final phase was eliminated.« less

  13. Dynamic intensity-weighted region of interest imaging for conebeam CT

    PubMed Central

    Pearson, Erik; Pan, Xiaochuan; Pelizzari, Charles

    2017-01-01

    BACKGROUND Patient dose from image guidance in radiotherapy is small compared to the treatment dose. However, the imaging beam is untargeted and deposits dose equally in tumor and healthy tissues. It is desirable to minimize imaging dose while maintaining efficacy. OBJECTIVE Image guidance typically does not require full image quality throughout the patient. Dynamic filtration of the kV beam allows local control of CT image noise for high quality around the target volume and lower quality elsewhere, with substantial dose sparing and reduced scatter fluence on the detector. METHODS The dynamic Intensity-Weighted Region of Interest (dIWROI) technique spatially varies beam intensity during acquisition with copper filter collimation. Fluence is reduced by 95% under the filters with the aperture conformed dynamically to the ROI during cone-beam CT scanning. Preprocessing to account for physical effects of the collimator before reconstruction is described. RESULTS Reconstructions show image quality comparable to a standard scan in the ROI, with higher noise and streak artifacts in the outer region but still adequate quality for patient localization. Monte Carlo modeling shows dose reduction by 10–15% in the ROI due to reduced scatter, and up to 75% outside. CONCLUSIONS The presented technique offers a method to reduce imaging dose by accepting increased image noise outside the ROI, while maintaining full image quality inside the ROI. PMID:27257875

  14. Nonlinear optical transmittance of semiconductors in the presence of high-intensity radiation fields

    NASA Astrophysics Data System (ADS)

    Dong, H. M.; Han, F. W.; Duan, Y. F.; Huang, F.; Liu, J. L.

    2018-04-01

    We developed a systematic theoretical study of nonlinear optical properties of semiconductors. The eight-band kṡp model and the energy-balance equation are employed to calculate the transmission and optical absorption coefficients in the presence of both the linear one-photon absorption and the nonlinear two-photon absorption (TPA) processes. A substantial reduction of the optical transmittance far below the band-gap can be observed under relatively high-intensity radiation fields due to the nonlinear TPA. The TPA-induced optical transmittance decreases with increasing intensity of the radiation fields. Our theoretical results are in line with those observed experimentally. The theoretical approach can be applied to understand the nonlinear optical properties of semiconductors under high-field conditions.

  15. High-Intensity Exercise as a Dishabituating Stimulus Restores Counterregulatory Responses in Recurrently Hypoglycemic Rodents.

    PubMed

    McNeilly, Alison D; Gallagher, Jennifer R; Huang, Jeffrey T-J; Ashford, Michael L J; McCrimmon, Rory J

    2017-06-01

    Hypoglycemia is a major adverse effect of insulin therapy for people with type 1 diabetes (T1D). Profound defects in the normal counterregulatory response to hypoglycemia explain the frequency of hypoglycemia occurrence in T1D. Defective counterregulation results to a large extent from prior exposure to hypoglycemia per se, leading to a condition called impaired awareness of hypoglycemia (IAH), the cause of which is unknown. In the current study, we investigate the hypothesis that IAH develops through a special type of adaptive memory referred to as habituation. To test this hypothesis, we used a novel intense stimulus (high-intensity exercise) to demonstrate two classic features of a habituated response, namely dishabituation and response recovery. We demonstrate that after recurrent hypoglycemia the introduction of a novel dishabituating stimulus (a single burst of high-intensity exercise) in male Sprague-Dawley rats restores the defective hypoglycemia counterregulatory response. In addition, the rats showed an enhanced response to the novel stimulus (response recovery). We make the further observation using proteomic analysis of hypothalamic extracts that high-intensity exercise in recurrently hypoglycemic rats increases levels of a number of proteins linked with brain-derived neurotrophic factor signaling. These findings may lead to novel therapeutic approaches for individuals with T1D and IAH. © 2017 by the American Diabetes Association.

  16. The Effect of Different Repeated-High-Intensity-Effort Bouts on Subsequent Running, Skill Performance, and Neuromuscular Function.

    PubMed

    Johnston, Rich D; Gabbett, Tim J; Jenkins, David G; Speranza, Michael J

    2016-04-01

    To assess the impact of different repeated-high-intensity-effort (RHIE) bouts on player activity profiles, skill involvements, and neuromuscular fatigue during small-sided games. 22 semiprofessional rugby league players (age 24.0 ± 1.8 y, body mass 95.6 ± 7.4 kg). During 4 testing sessions, they performed RHIE bouts that each differed in the combination of contact and running efforts, followed by a 5-min off-side small-sided game before performing a second bout of RHIE activity and another 5-min small-sided game. Global positioning system microtechnology and video recordings provided information on activity profiles and skill involvements. A countermovement jump and a plyometric push-up assessed changes in lower- and upper-body neuromuscular function after each session. After running-dominant RHIE bouts, players maintained running intensities during both games. In the contact-dominant RHIE bouts, reductions in moderate-speed activity were observed from game 1 to game 2 (ES = -0.71 to -1.06). There was also moderately lower disposal efficiency across both games after contact-dominant RHIE activity compared with running-dominant activity (ES = 0.62-1.02). Greater reductions in lower-body fatigue occurred as RHIE bouts became more running dominant (ES = -0.01 to -1.36), whereas upper-body fatigue increased as RHIE bouts became more contact dominant (ES = -0.07 to -1.55). Physical contact causes reductions in running intensity and the quality of skill involvements during game-based activities. In addition, the neuromuscular fatigue experienced by players is specific to the activities performed.

  17. High-intensity interval versus moderate-intensity continuous training: Superior metabolic benefits in diet-induced obesity mice.

    PubMed

    Wang, Ningning; Liu, Yang; Ma, Yanan; Wen, Deliang

    2017-12-15

    Exercise is beneficial in obesity, however, the debate about the value of high-intensity interval training (HIIT) vs. moderate-intensity continuous training (MICT) has been long lasting. Therefore, here we have compared the possible beneficial effects of two different exercise training regimes in a mouse model of diet-induced obesity (DIO). Following 7wk. on high fat diet (HFD), ten-week-old male ICR mice (n=30) were assigned to HIIT, distance-matched MICT or remained sedentary for the next 8 constitutive weeks while maintaining the dietary treatments. Age-matched sedentary mice with standard diet were used as a control (n=10). Exercise was performed on a motorized treadmill for 5days a week. Both modes of exercise ameliorated adiposity and related metabolic dysfunction induced by HFD and sedentary lifestyle, while mice following HIIT exhibited significantly lower body weight, percentage of fat mass and smaller adipocyte size. HIIT was more favorable in preventing liver lipid accumulation by restoring mRNA levels of genes involved in hepatic lipogenesis (SREBP1, ACC1, FAS) and β-oxidation (PPARα, CPT1a, HAD). In addition, HIIT was more efficient in mitigating adipose tissue inflammation and insulin insensitivity, partly dependent on abrogating phosphorylation of JNK/IRS1 (Ser307) pathway. Moreover, only HIIT led to pronounced beige adipocyte recruitment in inguinal subcutaneous adipose tissue. We conclude that HIIT contribute a more favorable regulation of metabolic dysfunctions in DIO mice compared with MICT. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Inequality in Preschool Quality? Community-Level Disparities in Access to High-Quality Learning Environments

    ERIC Educational Resources Information Center

    Bassok, Daphna; Galdo, Eva

    2016-01-01

    In recent years, unequal access to high-quality preschool has emerged as a growing public policy concern. Because of data limitations, it is notoriously difficult to measure disparities in access to early learning opportunities across communities and particularly challenging to quantify gaps in access to "high-quality" programs. Research…

  19. Multifunctional pulse generator for high-intensity focused ultrasound system

    NASA Astrophysics Data System (ADS)

    Tamano, Satoshi; Yoshizawa, Shin; Umemura, Shin-Ichiro

    2017-07-01

    High-intensity focused ultrasound (HIFU) can achieve high spatial resolution for the treatment of diseases. A major technical challenge in implementing a HIFU therapeutic system is to generate high-voltage high-current signals for effectively exciting a multichannel HIFU transducer at high efficiencies. In this paper, we present the development of a multifunctional multichannel generator/driver. The generator can produce a long burst as well as an extremely high-voltage short pulse of pseudosinusoidal waves (trigger HIFU) and second-harmonic superimposed waves for HIFU transmission. The transmission timing, waveform, and frequency can be controlled using a field-programmable gate array (FPGA) via a universal serial bus (USB) microcontroller. The hardware is implemented in a compact printed circuit board. The test results of trigger HIFU reveal that the power consumption and the temperature rise of metal-oxide semiconductor field-effect transistors were reduced by 19.9% and 38.2 °C, respectively, from the previous design. The highly flexible performance of the novel generator/driver is demonstrated in the generation of second-harmonic superimposed waves, which is useful for cavitation-enhanced HIFU treatment, although the previous design exhibited difficulty in generating it.

  20. Producing High Intense Attosecond Pulse Train by Interaction of Three-Color Pulse and Overdense Plasma

    NASA Astrophysics Data System (ADS)

    Salehi, M.; Mirzanejad, S.

    2017-05-01

    Amplifying the attosecond pulse by the chirp pulse amplification method is impossible. Furthermore, the intensity of attosecond pulse is low in the interaction of laser pulse and underdense plasma. This motivates us to propose using a multi-color pulse to produce the high intense attosecond pulse. In the present study, the relativistic interaction of a three-color linearly-polarized laser-pulse with highly overdense plasma is studied. We show that the combination of {{ω }}1, {{ω }}2 and {{ω }}3 frequencies decreases the instance full width at half maximum reflected attosecond pulse train from the overdense plasma surface. Moreover, we show that the three-color pulse increases the intensity of generated harmonics, which is explained by the relativistic oscillating mirror model. The obtained results demonstrate that if the three-color laser pulse interacts with overdense plasma, it will enhance two orders of magnitude of intensity of ultra short attosecond pulses in comparison with monochromatic pulse.