Indoor Air Quality in Schools: Clean Air Is Good Business.
ERIC Educational Resources Information Center
Guarneiri, Michele A.
2003-01-01
Describes the effect of poor indoor air quality (IAQ) on student health, the cost of safeguarding good IAQ, the cause of poor IAQ in schools, how to tell whether a school has an IAQ problem, and how the U.S. Environmental Protection Agency can help schools improve indoor air quality though the use of their free "Indoor Air Quality Tools for…
Indoor Air Quality Basics for Schools.
ERIC Educational Resources Information Center
Environmental Protection Agency, Washington, DC. Office of Radiation and Indoor Air.
This fact sheet details important information on Indoor Air Quality (IAQ) in school buildings, problems associated with IAQ, and various prevention and problem-solving strategies. Most people spend 90 percent of their time indoors, therefore the Environmental Protection Agency ranks IAQ in the top four environmental risks to the public. The…
A proactive approach for managing indoor air quality
DOE Office of Scientific and Technical Information (OSTI.GOV)
Greene, R.E.; Casey, J.M.; Williams, P.L.
1997-11-01
Ventilation and maintenance, followed by psychosocial issues, are the factors most often implicated in indoor air quality (IAQ) investigations. The absence of accepted exposure standards and the presence of a wide variety of building designs, ages, ventilation systems, and usages often make IAQ complaint investigations ineffective. Thus, the best approach to achieving IAQ is to prevent problems from occurring. This paper presents the framework for a proactive approach to managing the causes most often implicated in IAQ investigations. It is the aim of this proactive protocol to provide a cost-effective guide for preventing IAQ problems in nonindustrial settings and inmore » buildings for which there are no current IAQ complaints. The proposed protocol focuses on heating, ventilation, and air-conditioning (HVAC) system maintenance and operation; psychosocial factors; and the handling and investigation of complaints. An IAQ manager is designated to implement and manage the protocol. The HVAC system portion of the protocol focuses on proper maintenance of the components often identified as sources of problems in IAQ studies, documentation of the maintenance procedures, and training of individuals responsible for building maintenance. The protocol addresses the psychosocial factors with an environmental survey that rates the occupants` perceptions of the indoor air to identify potential IAQ problems. The psychosocial portion of the protocol also incorporates occupant education and awareness. Finally, a three-step initial investigation procedure for addressing IAQ problems is presented.« less
Causes of Indoor Air Quality Problems in Schools: Summary of Scientific Research.
ERIC Educational Resources Information Center
Bayer, Charlene W.; Crow, Sidney A.; Fischer, John
Research show that one in five U.S. schools has indoor air quality (IAQ) problems; 36 percent have inadequate heating, ventilation, and air conditioning (HVAC) systems; and there appears to be a correlation between IAQs and the proportion of a school's students coming from low-income households. This report examines the IAQ issue in U.S. public…
INDOOR AIR QUALITY MODELING (CHAPTER 58)
The chapter discussses indoor air quality (IAQ) modeling. Such modeling provides a way to investigate many IAQ problems without the expense of large field experiments. Where experiments are planned, IAQ models can be used to help design experiments by providing information on exp...
Reference Guide. Indoor Air Quality Tools for Schools
ERIC Educational Resources Information Center
US Environmental Protection Agency, 2009
2009-01-01
Understanding the importance of good indoor air quality (IAQ) in schools is the backbone of developing an effective Indoor Air Quality (IAQ) program. Poor IAQ can lead to a large variety of health problems and potentially affect comfort, concentration, and staff/student performance. In recognition of tight school budgets, this guidance is designed…
ERIC Educational Resources Information Center
Environmental Protection Agency, Washington, DC. Office of Radiation and Indoor Air.
The U.S. Environmental Protection Agency (EPA) developed the Indoor Air Quality Tools for Schools (IAQ TfS) Program to help schools prevent, identify, and resolve their IAQ problems. This publication describes the program and its advantages, explaining that through simple, low-cost measures, schools can: reduce IAQ-related health risks and…
There's Something in the Air: Indoor Air Quality in Schools.
ERIC Educational Resources Information Center
Schmidt, Edward A.
1994-01-01
Part 1 of this article, the first in a three-part series of articles that discuss indoor air quality (IAQ) issues affecting schools, provides a general overview of IAQ and discusses the three major health problems associated with IAQ: sick building syndrome, building-related illness, and multiple chemical sensitivity. (MLF)
Carrer, Paolo; Wolkoff, Peder
2018-04-12
There is an increasing concern about indoor air quality (IAQ) and its impact on health, comfort, and work-performance in office-like environments and their workers, which account for most of the labor force. The Scientific Committee on Indoor Air Quality and Health of the ICOH (Int. Comm. Occup. Health) has discussed the assessment and management of IAQ problems and proposed a stepwise approach to be conducted by a multidisciplinary team. It is recommended to integrate the building assessment, inspection by walk-through of the office workplace, questionnaire survey, and environmental measurements, in that order. The survey should cover perceived IAQ, symptoms, and psychosocial working aspects. The outcome can be used for mapping the IAQ and to prioritize the order in which problems should be dealt with. Individual health surveillance in relation to IAQ is proposed only when periodical health surveillance is already performed for other risks (e.g., video display units) or when specific clinical examination of workers is required due to the occurrence of diseases that may be linked to IAQ (e.g., Legionnaire's disease), recurrent inflammation, infections of eyes, respiratory airway effects, and sensorial disturbances. Environmental and personal risk factors should also be compiled and assessed. Workplace health promotion should include programs for smoking cessation and stress and IAQ management.
2018-01-01
There is an increasing concern about indoor air quality (IAQ) and its impact on health, comfort, and work-performance in office-like environments and their workers, which account for most of the labor force. The Scientific Committee on Indoor Air Quality and Health of the ICOH (Int. Comm. Occup. Health) has discussed the assessment and management of IAQ problems and proposed a stepwise approach to be conducted by a multidisciplinary team. It is recommended to integrate the building assessment, inspection by walk-through of the office workplace, questionnaire survey, and environmental measurements, in that order. The survey should cover perceived IAQ, symptoms, and psychosocial working aspects. The outcome can be used for mapping the IAQ and to prioritize the order in which problems should be dealt with. Individual health surveillance in relation to IAQ is proposed only when periodical health surveillance is already performed for other risks (e.g., video display units) or when specific clinical examination of workers is required due to the occurrence of diseases that may be linked to IAQ (e.g., Legionnaire’s disease), recurrent inflammation, infections of eyes, respiratory airway effects, and sensorial disturbances. Environmental and personal risk factors should also be compiled and assessed. Workplace health promotion should include programs for smoking cessation and stress and IAQ management. PMID:29649167
Indoor Air Quality Problem Solving Tool
Use the IAQ Problem Solving Tool to learn about the connection between health complaints and common solutions in schools. This resource provides an easy, step-by-step process to start identifying and resolving IAQ problems found at your school.
Indoor Air Quality Guidelines for Pennsylvania Schools.
ERIC Educational Resources Information Center
Zimmerman, Robert S., Jr.
This report provides information and practical guidance on how to prevent indoor air quality (IAQ) problems in schools, and it describes how to implement a practical plan of action using a minimal amount of resources. It includes general guidelines to prevent or help resolve IAQ problems, guidelines on specific indoor contaminants, recommendations…
Coordinator's Guide for Indoor Air Quality
IAQ Tools for Schools Action Kit - IAQ Coordinator's Guide. This guidance is designed to present practical and often low-cost actions you can take to identify and address existing or potential air quality problems.
ERIC Educational Resources Information Center
Singer, Terry E.; Shonkwiler, Tonja; Birr, David
1998-01-01
Examines how indoor air quality (IAQ) problems can create difficulties for a school both administratively, and legally. Discusses how to identify the IAQ symptoms and the Occupational Safety and Health Administration's industry standards for IAQ, as well as tips for reducing liability risk. (GR)
Carrer, Paolo; Muzi, Giacomo
2011-01-01
The role of the occupational health services in the assessment and management of indoor air quality (IAQ) problems in non-industrial sectors (offices, banks, etc.) has been discussed by experts of the ICOH Scientific Committee on IAQ and Health and has been proposed as follow: 1. Collaboration in risk assessment--risk management; 2. Questionnaire survey; 3. Health surveillance (only when periodical health surveillance is already performed for other risks or when specific clinical examination of workers is required); 4. Health promotion (programs for a better IAQ management). A team approach with cooperation between medical and technical experts is recommended in the assessment and management of indoor air quality problems.
Reference Guide for Indoor Air Quality in Schools
IAQ Tools for Schools Action Kit - IAQ Reference Guide. This guidance is designed to present practical and often low-cost actions you can take to identify and address existing or potential air quality problems.
Strategies for Limiting Engineers' Potential Liability for Indoor Air Quality Problems.
von Oppenfeld, Rolf R; Freeze, Mark E; Sabo, Sean M
1998-10-01
Engineers face indoor air quality (IAQ) issues at the design phase of building construction as well as during the investigation and mitigation of potential indoor air pollution problems during building operation. IAQ issues that can be identified are "building-related illnesses" that may include problems of volatile organic compounds (VOCs). IAQ issues that cannot be identified are termed "sick building syndrome." Frequently, microorganism-caused illnesses are difficult to confirm. Engineers who provide professional services that directly or indirectly impact IAQ face significant potential liability to clients and third parties when performing these duties. Potential theories supporting liability claims for IAQ problems against engineers include breach of contract and various common law tort theories such as negligence and negligent misrepresentation. Furthermore, an increasing number of federal, state, and local regulations affect IAQ issues and can directly increase the potential liability of engineers. A duty to disclose potential or actual air quality concerns to third parties may apply for engineers in given circumstances. Such a duty may arise from judicial precedent, the Model Guide for Professional Conduct for Engineers, or the Code of Ethics for Engineers. Practical strategies engineers can use to protect themselves from liability include regular training and continuing education in relevant regulatory, scientific, and case law developments; detailed documentation and recordkeeping practices; adequate insurance coverage; contractual indemnity clauses; contractual provisions limiting liability to the scope of work performed; and contractual provisions limiting the extent of liability for engineers' negligence. Furthermore, through the proper use of building materials and construction techniques, an engineer or other design professional can effectively limit the potential for IAQ liability.
Evaluation of Indoor Air Quality Screening Strategies: A Step-Wise Approach for IAQ Screening.
Wong, Ling-Tim; Mui, Kwok-Wai; Tsang, Tsz-Wun
2016-12-14
Conducting a full indoor air quality (IAQ) assessment in air-conditioned offices requires large-scale material and manpower resources. However, an IAQ index can be adopted as a handy screening tool to identify any premises (with poor IAQ) that need more comprehensive IAQ assessments to prioritize IAQ improvements. This study proposes a step-wise IAQ screening protocol to facilitate its cost-effective management among building owners and managers. The effectiveness of three IAQ indices, namely θ₁ (with one parameter: CO₂), θ₂ (with two parameters: CO₂ and respirable suspended particulates, RSP) and θ₃ (with three parameters: CO₂, RSP, and total volatile organic compounds, TVOC) are evaluated. Compared in a pairwise manner with respect to the minimum satisfaction levels as stated in the IAQ Certification Scheme by the Hong Kong Environmental Protection Department, the results show that a screening test with more surrogate IAQ parameters is good at identifying both lower and higher risk groups for unsatisfactory IAQ, and thus offers higher resolution. Through the sensitivity and specificity for identifying IAQ problems, the effectiveness of alternative IAQ screening methods with different monitoring parameters is also reported.
Evaluation of Indoor Air Quality Screening Strategies: A Step-Wise Approach for IAQ Screening
Wong, Ling-tim; Mui, Kwok-wai; Tsang, Tsz-wun
2016-01-01
Conducting a full indoor air quality (IAQ) assessment in air-conditioned offices requires large-scale material and manpower resources. However, an IAQ index can be adopted as a handy screening tool to identify any premises (with poor IAQ) that need more comprehensive IAQ assessments to prioritize IAQ improvements. This study proposes a step-wise IAQ screening protocol to facilitate its cost-effective management among building owners and managers. The effectiveness of three IAQ indices, namely θ1 (with one parameter: CO2), θ2 (with two parameters: CO2 and respirable suspended particulates, RSP) and θ3 (with three parameters: CO2, RSP, and total volatile organic compounds, TVOC) are evaluated. Compared in a pairwise manner with respect to the minimum satisfaction levels as stated in the IAQ Certification Scheme by the Hong Kong Environmental Protection Department, the results show that a screening test with more surrogate IAQ parameters is good at identifying both lower and higher risk groups for unsatisfactory IAQ, and thus offers higher resolution. Through the sensitivity and specificity for identifying IAQ problems, the effectiveness of alternative IAQ screening methods with different monitoring parameters is also reported. PMID:27983667
ERIC Educational Resources Information Center
American School & University, 1998
1998-01-01
Explores the steps to take to reduce the likelihood that indoor-air-quality (IAQ) problems will develop in educational facilities. Highlights sources and hazards of IAQ when renovating buildings; control strategies and the establishment of IAQ close-out criteria for all renovation projects; heating, ventilation, and air-conditioning system…
ERIC Educational Resources Information Center
Seyffer, Charles
1999-01-01
Discusses how to spot indoor air quality (IAQ) problems in schools and possible actions to take to eliminate them. Highlights the types of pollutants that contribute to IAQ deterioration and the physical symptoms commonly associated with them, and suggests ways of addressing older heating, ventilation, and air conditioning systems to improve air…
Advisory on Relocatable and Renovated Classrooms. IAQ Info Sheet.
ERIC Educational Resources Information Center
California State Dept. of Health Services, Berkeley.
Many California school districts, in complying with the Class Size Reduction Program, will obtain relocatable classrooms directly from manufacturers who are under no specific guidelines or codes relative to indoor air quality (IAQ). This document, designed to aid school facility managers in minimizing potential IAQ problems, summarizes the indoor…
Finell, E; Haverinen-Shaughnessy, U; Tolvanen, A; Laaksonen, S; Karvonen, S; Sund, R; Saaristo, V; Luopa, P; Ståhl, T; Putus, T; Pekkanen, J
2017-03-01
Subjective evaluation of Indoor Air Quality (subjective IAQ) reflects both building-related and psychosocial factors, but their associations have rarely been studied other than on the individual level in occupational settings and their interactions have not been assessed. Therefore, we studied whether schools' observed indoor air problems and psychosocial factors are associated with subjective IAQ and their potential interactions. The analysis was performed with a nationwide sample (N = 195 schools/26946 students) using multilevel modeling. Two datasets were merged: (i) survey data from students, including information on schools' psychosocial environment and subjective IAQ, and (ii) data from school principals, including information on observed indoor air problems. On the student level, school-related stress, poor teacher-student relationship, and whether the student did not easily receive help from school personnel, were significantly associated with poor subjective IAQ. On the school level, observed indoor air problem (standardized β = -0.43) and poor teacher-student relationship (standardized β = -0.22) were significant predictors of poor subjective IAQ. In addition, school-related stress was associated with poor subjective IAQ, but only in schools without observed indoor air problem (standardized β = -0.44). © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
ERIC Educational Resources Information Center
Quraishi, Arif; Kapfer, Tom
1999-01-01
Presents practical solutions to school indoor-air-quality problems. Areas where school administrators should set IAQ goals and provide resources are listed, and tips for HVAC maintenance and cleaning to reduce air pollutants are provided. (GR)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1989-09-01
The National Institute for Occupational Safety and Health (NIOSH) has compiled the document in response to an increasing number of requests for information about indoor air quality (IAQ), including sick building syndrome. Included in the publication are: NIOSH Congressional testimony that describes the NIOSH IAQ investigations program and summarizes the results of NIOSH research and findings on IAQ problems, NIOSH guidance for conducting indoor air quality investigations, NIOSH journal article on evaluating building ventilation systems, and list of non-NIOSH publications on indoor air quality. As the Federal agency responsible for conducting research and making recommendations for occupational safety and healthmore » standards, NIOSH limits its IAQ activities to the occupational environment. The U.S. Environmental Protection Agency (EPA) also conducts an IAQ program and can be contacted for information regarding both occupational and non-occupational settings.« less
Kuo, Nae-Wen; Chiang, Hsin-Chen; Chiang, Che-Ming
2008-12-01
Indoor air quality (IAQ) has begun to surface as an important issue that affects the comfort and health of people; however, there is little research concerned about the IAQ monitoring of hotels up to now. Hotels are designed to provide comfortable spaces for guests. However, most complaints related to uncomfortable thermal environment and inadequate indoor air quality appear. In addition, microbial pollution can affect the health of tourists such as the Legionnaire's disease and SARS problems. This study is aimed to establish the comprehensive IAQ audit approach for hotel buildings with portable equipment, and one five-star international hotel in Taiwan was selected to exam this integrated approach. Finally, four major problems are identified after the comprehensive IAQ audit. They are: (1) low room temperature (21.8 degrees C), (2) insufficient air exchange rate (<1.5 h(-1)), (3) formaldehyde contamination (>0.02 ppm), and (4) the microbial pollution (total bacteria: 2,624-3,799 CFU/m(3)). The high level of formaldehyde may be due to the emission from the detergent and cleaning agents used for housekeeping.
ERIC Educational Resources Information Center
Daisey, Joan M.; Angell, William J.
This report presents detailed results from a survey and critical review of existing published literature and reports on indoor air quality (IAQ), ventilation, and IAQ- and building-related health problems in schools, particularly California schools. The findings: (1) identify the most commonly reported building-related health symtoms involving…
ERIC Educational Resources Information Center
High, Jacalyn
2010-01-01
Poor indoor air quality (IAQ) in schools and universities contributes to absenteeism and reduced performance. The American Lung Association estimates that U.S. students miss more than 14 million school days a year because of asthma, allergies and other respiratory problems exacerbated by poor IAQ. Fortunately, maintenance departments in education…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sliwinski, B.J.; Kermath, D.; Kemme, M.R.
There is a growing body of information related to facility indoor air quality (IAQ) and its affect on the health and productivity of building occupants. Indoor air pollution can increase employee absenteeism and reduce productivity. Poor IAQ may be a result of poor building or ventilation design, improper maintenance, or inappropriate energy conservation strategies. To help ensure the health, welfare, and productivity of Army personnel and the performance of Army facilities, installation operations and maintenance (O and M) personnel need access to relevant and useful information about IAQ issues. This report includes background information for O and M managers andmore » staff, an installation-level IAQ management plan, and practical O and M procedures for correcting the problems that most commonly lead to IAQ-related complaints.« less
How to Create Healthy Indoor Environments in Schools
ERIC Educational Resources Information Center
Rhodes, Diane; Di Nella, Frank
2012-01-01
A green and healthy indoor environment should be a fundamental concern in the place where kids learn and grow. Good indoor air quality (IAQ) has been shown to have positive effects on student and staff productivity, performance, comfort and attendance. Conversely, poor IAQ in classrooms--caused by mold and moisture issues, problems with HVAC…
A systematic indoor air quality audit approach for public buildings.
Asadi, Ehsan; da Silva, Manuel C Gameiro; Costa, J J
2013-01-01
Good indoor air quality (IAQ) in buildings provides a comfortable and healthy environment for the occupants to work, learn, study, etc. Therefore, it is important to ascertain the IAQ status in the buildings. This study is aimed to establish and demonstrate the comprehensive IAQ audit approach for public buildings, based on Portugal national laws. Four public buildings in Portugal are used to demonstrate the IAQ audit application. The systematic approach involves the measurement of physical parameters (temperature, relative humidity, and concentration of the suspended particulate matter), monitoring of the concentrations of selected chemical indicators [carbon dioxide (CO(2)), carbon monoxide, formaldehyde, ozone, and total volatile organic compounds], and the measurements of biological indicators (bacteria and fungi). In addition, air exchange rates are measured by the concentration decay method using metabolic CO(2) as the tracer gas. The comprehensive audits indicated some situations of common IAQ problems in buildings, namely: (1) insufficient ventilation rate, (2) too high particle concentration; and (3) poor filtration effectiveness and hygienic conditions in most of the air handling units. Accordingly, a set of recommendations for the improvement of IAQ conditions were advised to the building owner/managers.
Kim, MinJeong; Liu, Hongbin; Kim, Jeong Tai; Yoo, ChangKyoo
2014-08-15
Sensor faults in metro systems provide incorrect information to indoor air quality (IAQ) ventilation systems, resulting in the miss-operation of ventilation systems and adverse effects on passenger health. In this study, a new sensor validation method is proposed to (1) detect, identify and repair sensor faults and (2) evaluate the influence of sensor reliability on passenger health risk. To address the dynamic non-Gaussianity problem of IAQ data, dynamic independent component analysis (DICA) is used. To detect and identify sensor faults, the DICA-based squared prediction error and sensor validity index are used, respectively. To restore the faults to normal measurements, a DICA-based iterative reconstruction algorithm is proposed. The comprehensive indoor air-quality index (CIAI) that evaluates the influence of the current IAQ on passenger health is then compared using the faulty and reconstructed IAQ data sets. Experimental results from a metro station showed that the DICA-based method can produce an improved IAQ level in the metro station and reduce passenger health risk since it more accurately validates sensor faults than do conventional methods. Copyright © 2014 Elsevier B.V. All rights reserved.
Practical approaches for health care: Indoor air quality management
DOE Office of Scientific and Technical Information (OSTI.GOV)
Turk, A.R.; Poulakos, E.M.
1996-05-01
The management of indoor air quality (IAQ) is of interest to building occupants, managers, owners, and regulators alike. Whether by poor design, improper attention, inadequate maintenance or the intent to save energy, many buildings today have significantly degraded IAQ levels. Acceptable IAQ is defined by the American Society of Heating, Refrigerating, and Air Conditioning Engineers (ASHRAE) in Standard 62-1989 {open_quotes}Ventilation for Acceptable Indoor Air Quality{close_quotes} as {open_quotes}air in which there are no known contaminants at harmful concentrations as determined by cognizant authorities and with which a substantial majority (80 percent or more) of the people exposed do not express dissatisfaction.{close_quotes}more » ASHRAE`s definition not only addresses the chemical compounds that may be present in the air, but it also recognizes a need to address both physiological and psychosocial comfort. The second step is to conduct a performance review of the HVAC systems based on equipment design specifications and guidelines for acceptable IAQ. And the third step is to identify potential chemical, physical and biological sources that are known to contribute to adverse air quality. Upon completion of these three steps, you will able to identify the more significant contributors to IAQ problems and establish applications for prevention and mitigation.« less
Indoor Air Quality Tools for Schools Action Kit. Second Edition.
ERIC Educational Resources Information Center
Environmental Protection Agency, Washington, DC.
This kit contains materials to assist a school indoor air quality (IAQ) coordinator in conducting a school IAQ program. The kit contains the following: IAQ coordinator's guide; IAQ coordinator forms; IAQ backgrounder; teacher's classroom checklist; administrative staff checklist; health officer/school nurse checklist; ventilation checklist and…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Allan; Vine, Edward L.
The incidence of commercial buildings with poor indoor air quality (IAQ), and the frequency of litigation over the effects of poor IAQ is increasing. If so, these increases have ramifications for insurance carriers, which pay for many of the costs of health care and general commercial liability. However, little is known about the actual costs to insurance companies from poor IAQ in buildings. This paper reports on the results of a literature search of buildings-related, business and legal databases, and interviews with insurance and risk management representatives aimed at finding information on the direct costs to the insurance industry ofmore » poor building IAQ, as well as the costs of litigation. The literature search and discussions with insurance and risk management professionals reported in this paper turned up little specific information about the costs of IAQ-related problems to insurance companies. However, those discussions and certain articles in the insurance industry press indicate that there is a strong awareness and growing concern over the "silent crisis" of IAQ and its potential to cause large industry losses, and that a few companies are taking steps to address this issue. The source of these losses include both direct costs to insurers from paying health insurance and professional liability claims, as weIl as the cost of litigation. In spite of the lack of data on how IAQ-related health problems affect their business, the insurance industry has taken the anecdotal evidence about their reality seriously enough to alter their policies in ways that have lessened their exposure. We conclude by briefly discussing four activities that need to be addressed in the near future: (1) quantifying IAQ-related insurance costs by sector, (2) educating the insurance industry about the importance of IAQ issues, (3) examining IAQ impacts on the insurance industry in the residential sector, and (4) evaluating the relationship between IAQ improvements and their impact on energy use.« less
Causes of Indoor Air Quality Problems in Schools: Summary of Scientific Research
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bayer, C.W.
2001-02-22
In the modern urban setting, most individuals spend about 80% of their time indoors and are therefore exposed to the indoor environment to a much greater extent than to the outdoors (Lebowitz 1992). Concomitant with this increased habitation in urban buildings, there have been numerous reports of adverse health effects related to indoor air quality (IAQ) (sick buildings). Most of these buildings were built in the last two decades and were constructed to be energy-efficient. The quality of air in the indoor environment can be altered by a number of factors: release of volatile compounds from furnishings, floor and wallmore » coverings, and other finishing materials or machinery; inadequate ventilation; poor temperature and humidity control; re-entrainment of outdoor volatile organic compounds (VOCs); and the contamination of the indoor environment by microbes (particularly fungi). Armstrong Laboratory (1992) found that the three most frequent causes of IAQ are (1) inadequate design and/or maintenance of the heating, ventilation, and air-conditioning (HVAC) system, (2) a shortage of fresh air, and (3) lack of humidity control. A similar study by the National Institute for Occupational Safety and Health (NIOSH 1989) recognized inadequate ventilation as the most frequent source of IAQ problems in the work environment (52% of the time). Poor IAQ due to microbial contamination can be the result of the complex interactions of physical, chemical, and biological factors. Harmful fungal populations, once established in the HVAC system or occupied space of a modern building, may episodically produce or intensify what is known as sick building syndrome (SBS) (Cummings and Withers 1998). Indeed, SBS caused by fungi may be more enduring and recalcitrant to treatment than SBS from multiple chemical exposures (Andrae 1988). An understanding of the microbial ecology of the indoor environment is crucial to ultimately resolving many IAQ problems. The incidence of SBS related to multiple chemical sensitivity versus bioaerosols (aerosolized microbes), or the contribution of the microorganisms to the chemical sensitivities, is not yet understood. If the inhabitants of a building exhibit similar symptoms of a clearly defined disease with a nature and time of onset that can be related to building occupancy, the disease is generally referred to as ''building-related illness.'' Once the SBS has been allowed to elevate to this level, buildings are typically evacuated and the costs associated with disruption of the building occupants, identification of the source of the problem, and eventual remediation can be significant. Understanding the primary causes of IAQ problems and how controllable factors--proper HVAC system design, allocation of adequate outdoor air, proper filtration, effective humidity control, and routine maintenance--can avert the problems may help all building owners, operators, and occupants to be more productive (Arens and Baughman 1996). This paper provides a comprehensive summary of IAQ research that has been conducted in various types of facilities. However, it focuses primarily on school facilities because, for numerous reasons that will become evident, they are far more susceptible to developing IAQ problems than most other types of facilities; and the occupants, children, are more significantly affected than adults (EPA 1998).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dickson, R.B.
Indoor air pollution (IAP) is ranked by the Environmental Protection Agency (EPA) among the top five environmental risks to human health. The World Health Organization estimates that nearly one in every six commercial buildings in the United States suffers from sick-building syndrome and that occupants of another one in twelve suffer from building-related illnesses. Indoor air quality (IAQ) problems cost American business $10 billion per year through lowered productivity, absenteeism, and medical costs. Yet despite the importance and high cost of IAQ problems, indoor air is not yet specifically addressed in any federal regulatory program. The reason probably is becausemore » indoor air is a quanitatively different environment in which traditional modes of regulation, based on pollutant-by pollutant risk assessments, are of limited utility. This paper covers the following topics: four factors influencing IAQ regulation; EPA regulation of indoor air; the role of the consumer product safety commission; OSHA and IAQ issues; state regulation and economic concerns; the pressure for legislation.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haymore, C.; Odom, R.
Poor indoor air quality (IAQ) takes its toll in a variety of ways. It damages health and possessions; it lowers productivity at work; and it diverts resources to diagnosing and solving problems that result from it. Although the economic costs of some of these damages are fairly tangible and easy to quantify, a large portion are hidden. The cumulative impact can easily reach into the billions of dollars. The cost to diagnose, mitigate, and litigate IAQ problems is evidenced by the burgeoning number of businesses providing these services. A recent EPA survey indicated that over 1,500 firms specialize in IAQmore » services, a 25-percent increase from 1988. The median price for evaluating and balancing ventilation systems ranges from $250 to $1,500. The median for duct-cleaning service is about $500 and for asbestos abatement and construction/renovation, about $5,000. Costs can be as high as $50,000 for some of these services. The economic costs of poor IAQ also include the actual damages to property caused by contaminants. Indoor air pollutants can damage metals, paints, textiles, paper, and magnetic storage media and can cause increased soiling, deterioration of appearance, and reduced service life for furniture draperies, interiors, and heating, ventilation, and air conditioning (HVAC) equipment. Injury to people represent an even larger cost of poor IAQ. EPA ranks IAQ problems as one of the largest remaining health risks in the US. Health effects range from the mildly irritating, such as headaches and allergies, to the life threatening, such as cancer and heart disease. One study indicated that for every 100 white collar workers, poor IAQ would cause an extra 24 doctor visits per year. This amounts to another $288 million.« less
Vornanen-Winqvist, Camilla; Järvi, Kati; Toomla, Sander; Ahmed, Kaiser; Andersson, Maria A.; Mikkola, Raimo; Marik, Tamás; Salonen, Heidi
2018-01-01
This case study investigates the effects of ventilation intervention on measured and perceived indoor air quality (IAQ) in a repaired school where occupants reported IAQ problems. Occupants’ symptoms were suspected to be related to the impurities leaked indoors through the building envelope. The study’s aim was to determine whether a positive pressure of 5–7 Pa prevents the infiltration of harmful chemical and microbiological agents from structures, thus decreasing symptoms and discomfort. Ventilation intervention was conducted in a building section comprising 12 classrooms and was completed with IAQ measurements and occupants’ questionnaires. After intervention, the concentration of total volatile organic compounds (TVOC) and fine particulate matter (PM2.5) decreased, and occupants’ negative perceptions became more moderate compared to those for other parts of the building. The indoor mycobiota differed in species composition from the outdoor mycobiota, and changed remarkably with the intervention, indicating that some species may have emanated from an indoor source before the intervention. PMID:29385772
Vornanen-Winqvist, Camilla; Järvi, Kati; Toomla, Sander; Ahmed, Kaiser; Andersson, Maria A; Mikkola, Raimo; Marik, Tamás; Kredics, László; Salonen, Heidi; Kurnitski, Jarek
2018-01-30
This case study investigates the effects of ventilation intervention on measured and perceived indoor air quality (IAQ) in a repaired school where occupants reported IAQ problems. Occupants' symptoms were suspected to be related to the impurities leaked indoors through the building envelope. The study's aim was to determine whether a positive pressure of 5-7 Pa prevents the infiltration of harmful chemical and microbiological agents from structures, thus decreasing symptoms and discomfort. Ventilation intervention was conducted in a building section comprising 12 classrooms and was completed with IAQ measurements and occupants' questionnaires. After intervention, the concentration of total volatile organic compounds (TVOC) and fine particulate matter (PM 2.5 ) decreased, and occupants' negative perceptions became more moderate compared to those for other parts of the building. The indoor mycobiota differed in species composition from the outdoor mycobiota, and changed remarkably with the intervention, indicating that some species may have emanated from an indoor source before the intervention.
Association between Four-Level Categorisation of Indoor Exposure and Perceived Indoor Air Quality.
Tähtinen, Katja; Lappalainen, Sanna; Karvala, Kirsi; Remes, Jouko; Salonen, Heidi
2018-04-04
The aim of this study was to develop and test a tool for assessing urgency of indoor air quality (IAQ) measures. The condition of the 27 buildings were investigated and results were categorized. Statistical test studied the differences between the categories and the employees’ complaints about their work environment. To study the employees’ experiences of the work premises, a validated indoor air (IA) questionnaire was used. This study reveals a multifaceted problem: many factors affecting IAQ may also affect perceived IAQ, making it difficult to separate the impurity sources and ventilation system deficiencies affecting to employee experiences. An examination of the relationship between the categories and perceived IAQ revealed an association between the mould odour perceived by employees and mould detected by the researcher. A weak link was also found between the assessed categories and environmental complaints. However, we cannot make far-reaching conclusions regarding the assessed probability of abnormal IA exposure in the building on the basis of employee experiences. According to the results, categorising tool can partly support the assessment of the urgency for repairs when several factors that affect IAQ are taken into account.
Association between Four-Level Categorisation of Indoor Exposure and Perceived Indoor Air Quality
Tähtinen, Katja; Lappalainen, Sanna; Karvala, Kirsi; Remes, Jouko; Salonen, Heidi
2018-01-01
The aim of this study was to develop and test a tool for assessing urgency of indoor air quality (IAQ) measures. The condition of the 27 buildings were investigated and results were categorized. Statistical test studied the differences between the categories and the employees’ complaints about their work environment. To study the employees’ experiences of the work premises, a validated indoor air (IA) questionnaire was used. This study reveals a multifaceted problem: many factors affecting IAQ may also affect perceived IAQ, making it difficult to separate the impurity sources and ventilation system deficiencies affecting to employee experiences. An examination of the relationship between the categories and perceived IAQ revealed an association between the mould odour perceived by employees and mould detected by the researcher. A weak link was also found between the assessed categories and environmental complaints. However, we cannot make far-reaching conclusions regarding the assessed probability of abnormal IA exposure in the building on the basis of employee experiences. According to the results, categorising tool can partly support the assessment of the urgency for repairs when several factors that affect IAQ are taken into account. PMID:29617335
Indoor Air Quality and Respiratory Health among Malay Preschool Children in Selangor.
Rawi, Nur Azwani Mohd Nor; Jalaludin, Juliana; Chua, Poh Choo
2015-01-01
Indoor air quality (IAQ) has been the object of several studies due to its adverse health effects on children. Methods. A cross-sectional comparative study was carried out among Malay children in Balakong (2 studied preschools) and Bangi (2 comparative preschools), Selangor, with the aims of determining IAQ and its association with respiratory health. 61 and 50 children aged 5-6 years were selected as studied and comparative groups. A questionnaire was used to obtain an exposure history and respiratory symptoms. Lung function test was carried out. IAQ parameters obtained include indoor concentration of particulate matter (PM), volatile organic compounds (VOCs), carbon monoxide (CO), carbon dioxide (CO2), temperature, air velocity (AV), and relative humidity. Results. There was a significant difference between IAQ in studied and comparative preschools for all parameters measured (P < 0.001) except for CO2 and AV. Studied preschools had higher PM and CO concentration. FVC, FEV1, FVC% and FEV1% predicted values were significantly lower among studied group. Exposures to PM, VOCs, and CO were associated with wheezing. Conclusion. The finding concluded that exposures to poor IAQ might increase the risk of getting lung function abnormality and respiratory problems among study respondents.
Indoor Air Quality and Respiratory Health among Malay Preschool Children in Selangor
Chua, Poh Choo
2015-01-01
Indoor air quality (IAQ) has been the object of several studies due to its adverse health effects on children. Methods. A cross-sectional comparative study was carried out among Malay children in Balakong (2 studied preschools) and Bangi (2 comparative preschools), Selangor, with the aims of determining IAQ and its association with respiratory health. 61 and 50 children aged 5-6 years were selected as studied and comparative groups. A questionnaire was used to obtain an exposure history and respiratory symptoms. Lung function test was carried out. IAQ parameters obtained include indoor concentration of particulate matter (PM), volatile organic compounds (VOCs), carbon monoxide (CO), carbon dioxide (CO2), temperature, air velocity (AV), and relative humidity. Results. There was a significant difference between IAQ in studied and comparative preschools for all parameters measured (P < 0.001) except for CO2 and AV. Studied preschools had higher PM and CO concentration. FVC, FEV1, FVC% and FEV1% predicted values were significantly lower among studied group. Exposures to PM, VOCs, and CO were associated with wheezing. Conclusion. The finding concluded that exposures to poor IAQ might increase the risk of getting lung function abnormality and respiratory problems among study respondents. PMID:25984527
Causes of Indoor Air Quality Problems in Schools: Summary of Scientific Research. Revised Edition.
ERIC Educational Resources Information Center
Bayer, Charlene W.; Crow, Sidney A.; Fischer, John
Understanding the primary causes of indoor air quality (IAQ) problems and how controllable factors--proper heating, ventilation and air-conditioning (HVAC) system design, allocation of adequate outdoor air, proper filtration, effective humidity control, and routine maintenance--can avert problems may help all building owners, operators, and…
Building Air Quality Guide: A Guide for Building Owners and Facility Managers
The Building Air Quality, developed by the EPA and the National Institute for Occupational Safety and Health, provides practical suggestions on preventing, identifying, and resolving indoor air quality (IAQ) problems in public and commercial buildings.
Classifying Sources Influencing Indoor Air Quality (IAQ) Using Artificial Neural Network (ANN)
Mad Saad, Shaharil; Melvin Andrew, Allan; Md Shakaff, Ali Yeon; Mohd Saad, Abdul Rahman; Muhamad Yusof @ Kamarudin, Azman; Zakaria, Ammar
2015-01-01
Monitoring indoor air quality (IAQ) is deemed important nowadays. A sophisticated IAQ monitoring system which could classify the source influencing the IAQ is definitely going to be very helpful to the users. Therefore, in this paper, an IAQ monitoring system has been proposed with a newly added feature which enables the system to identify the sources influencing the level of IAQ. In order to achieve this, the data collected has been trained with artificial neural network or ANN—a proven method for pattern recognition. Basically, the proposed system consists of sensor module cloud (SMC), base station and service-oriented client. The SMC contain collections of sensor modules that measure the air quality data and transmit the captured data to base station through wireless network. The IAQ monitoring system is also equipped with IAQ Index and thermal comfort index which could tell the users about the room’s conditions. The results showed that the system is able to measure the level of air quality and successfully classify the sources influencing IAQ in various environments like ambient air, chemical presence, fragrance presence, foods and beverages and human activity. PMID:26007724
Indoor air quality investigation and health risk assessment at correctional institutions.
Ofungwu, Joseph
2005-04-01
A comprehensive indoor air-quality (IAQ) investigation was conducted at a state correctional facility in New Jersey, USA with a lengthy history of IAQ problems. The IAQ investigation comprised preliminary indoor air screening using direct readout instrumentation, indoor air/surface wipe sampling and laboratory analysis, as well as a heating, ventilation, and air-conditioning system evaluation, and a building envelope survey. In addition to air sampling, a human health risk assessment was performed to evaluate the potential for exposure to site-related air contaminants with respect to the inmate and worker populations. The risk assessment results for the prison facility indicated the potential for significant health risks for the inmate population, possibly reflecting the effects of their confinement and extended exposure to indoor air contaminants, as compared to the prison guard and worker population. Based on the results of the risk assessment, several mitigation measures are recommended to minimize prison population health risks and improve indoor air quality at prison facilities.
[Influence of Moxa Smoke on Indoor Air Quality and Strategies for Its Control].
Yu, Chang; Wu, Qiao-Feng; Tang, Yong; Yu, Shu-Guang
2018-02-25
Moxibustion is an effective therapy for treatment of a lot of clinical problems, but the ignited moxa-induced smoke containing harmful substances may bring about indoor air pollution to affect both patients' and medical workers' health. However, there is no standards about controlling indoor air quality (IAQ) for moxibustion rooms in China. In the present study, the authors reviewed newly-published articles about some substances released from moxa smoke as inhalable particles (PM 10 and PM 2.5), formaldehyde, benzene, methylbenzene, xylene, bene[α]pyrene, total volatile organic compounds, CO, CO 2 , NO, SO 2 , NH 3 , O 3 , etc. some of which affect IAQ. On this account, the authors put forward some strategies for controlling IAQ in moxibustion clinics including setting united safe standards, enhancing ventilation, controlling moxibustion material quality and strengthening scientific research on the safety of moxa smoke control, fully playing the superiority of moxibustion therapy and reducing its unfavorable aspects in clinical practice in the future.
Construction, Part of Indoor Air Quality Design Tools for Schools
Poor job-site construction practices can frustrate even the best design by allowing moisture and other contaminants to become potential long term problems. Preventive job-site practices will reduce the potential for residual problems with IAQ
ERIC Educational Resources Information Center
Odom, J. David; DuBose, George
This manual addresses the errors that occur during new construction that subsequently contribute to indoor air quality (IAQ) problems in newly constructed buildings in hot and humid climates, and offers guidelines for preventing them during the design and construction phases. It defines the roles and responsibilities of the design team, the…
Parent's Guide to School Indoor Air Quality. Revised
ERIC Educational Resources Information Center
Healthy Schools Network, Inc., 2012
2012-01-01
Air pollution is air pollution, indoors or out. Good indoor air quality (IAQ) contributes to a favorable learning environment for students, protects health, and supports the productivity of school personnel. In schools in poor repair, leaky roofs and crumbling walls have caused additional indoor air quality problems, including contamination with…
MANAGING INDOOR AIR QUALITY IN THE USA
The paper gives an overview of managing indoor air quality (IAQ) in the U.S. In contrast to outdoor air, which is regulated through various federal and state statutes, there is no unified and comprehensive governmental regulation of IAQ. Therefore, IAQ is managed through variou...
COMPARISON OF DATA FROM AN IAQ TEST HOUSE WITH PREDICTIONS OF AN IAQ COMPUTER MODEL
The paper describes several experiments to evaluate the impact of indoor air pollutant sources on indoor air quality (IAQ). Measured pollutant concentrations are compared with concentrations predicted by an IAQ model. The measured concentrations are in excellent agreement with th...
ERIC Educational Resources Information Center
Everett Jones, Sherry; Doroski, Brenda; Glick, Sherry
2015-01-01
Nationally representative data from the 2012 School Health Policies and Practices Study examined whether state assistance on indoor air quality (IAQ) was associated with district-level policies and practices related to IAQ and integrated pest management (IPM). Districts in states that provided assistance on IAQ were more likely than districts not…
Emission models developed using small chamber data were combined with an Indoor Air Quality (IAQ) model to analyze the impact of volatile organic compound (VOC) emissions from latex paint on indoor environments. Test house experiments were conducted to verify the IAQ model's pred...
ERIC Educational Resources Information Center
Colgan, Craig
2003-01-01
Mold and indoor air quality (IAQ) are matters of major concern to architects and their educational clients. The Environmental Protection Agency's Indoor Air Quality Tools for Schools program offers help to districts seeking to tackle IAQ issues. Strengthening community relations is one way to be ready in case of a bad environmental or IAQ report.…
Provides overview of Assessing IAQ by downloading EPA's School Assessment Mobile App. “One-stop shop” for accessing guidance from EPA’s IAQ Tools for Schools Action Kit with proven strategies for specifically addressing important IAQ issues.
ERIC Educational Resources Information Center
US Environmental Protection Agency, 2009
2009-01-01
This issue of "Indoor Air Quality Tools for Schools" Update ("IAQ TfS" Update) contains the following items: (1) News and Events; (2) Feature Article: Reduce Energy Costs while Maintaining Healthy IAQ; (3) Insight into Excellence: North East Independent School District ; (4) School Building Week 2009; and (5) Have Your Questions Answered!
[Establishing IAQ Metrics and Baseline Measures.] "Indoor Air Quality Tools for Schools" Update #20
ERIC Educational Resources Information Center
US Environmental Protection Agency, 2009
2009-01-01
This issue of "Indoor Air Quality Tools for Schools" Update ("IAQ TfS" Update) contains the following items: (1) News and Events; (2) IAQ Profile: Establishing Your Baseline for Long-Term Success (Feature Article); (3) Insight into Excellence: Belleville Township High School District #201, 2009 Leadership Award Winner; and (4) Have Your Questions…
Indoor Air Quality Tools for Schools Action Kit
The IAQ Tools for Schools Action Kit provides schools with information on how to carry out a practical plan to improve indoor air problems at little- or no-cost using straightforward activities and in-house staff.
Indoor Air Quality: Tools for Schools Action Kit.
ERIC Educational Resources Information Center
Environmental Protection Agency, Washington, DC. Indoor Air Div.
Good indoor air quality contributes to a favorable learning environment for students, productivity for teachers and staff, and a sense of comfort, health, and well-being for all school occupants. The goal of this kit is to provide clear and easily applied guidance that will help prevent Indoor Air Quality (IAQ) problems and resolve such problems…
Healthier Schools: A Review of State Policies for Improving Indoor Air Quality. Research Report.
ERIC Educational Resources Information Center
Bernstein, Tobie
Existing indoor air quality (IAQ) policies for schools reflect the variety of institutional, political, social, and economic contexts that exist within individual states. The purpose of this report is to provide a better understanding of the types of policy strategies used by states in addressing general indoor air quality problems. The policies…
Indoor Air Quality Tribal Partners Program
IAQ Tribal Partners Program. Empowering champions of healthy IAQ in tribal communities with tools for networking, sharing innovative and promising programs and practices and a reservoir of the best available tribal-specific IAQ information and materials.
ERIC Educational Resources Information Center
Lin, Shao; Kielb, Christine L.; Reddy, Amanda L.; Chapman, Bonnie R.; Hwang, Syni-An
2012-01-01
Background: Good school indoor air quality (IAQ) can affect the health and functioning of school occupants. Thus, it is important to assess the degree to which schools and districts employ strategies to ensure good IAQ management. We examined and compared the patterns of IAQ management strategies between public elementary schools and their school…
Syazwan, AI; Rafee, B Mohd; Hafizan, Juahir; Azman, AZF; Nizar, AM; Izwyn, Z; Muhaimin, AA; Yunos, MA Syafiq; Anita, AR; Hanafiah, J Muhamad; Shaharuddin, MS; Ibthisham, A Mohd; Ismail, Mohd Hasmadi; Azhar, MN Mohamad; Azizan, HS; Zulfadhli, I; Othman, J
2012-01-01
Background To meet the current diversified health needs in workplaces, especially in nonindustrial workplaces in developing countries, an indoor air quality (IAQ) component of a participatory occupational safety and health survey should be included. Objectives The purpose of this study was to evaluate and suggest a multidisciplinary, integrated IAQ checklist for evaluating the health risk of building occupants. This IAQ checklist proposed to support employers, workers, and assessors in understanding a wide range of important elements in the indoor air environment to promote awareness in nonindustrial workplaces. Methods The general structure of and specific items in the IAQ checklist were discussed in a focus group meeting with IAQ assessors based upon the result of a literature review, previous industrial code of practice, and previous interviews with company employers and workers. Results For practicality and validity, several sessions were held to elicit the opinions of company members, and, as a result, modifications were made. The newly developed IAQ checklist was finally formulated, consisting of seven core areas, nine technical areas, and 71 essential items. Each item was linked to a suitable section in the Industry Code of Practice on Indoor Air Quality published by the Department of Occupational Safety and Health. Conclusion Combined usage of an IAQ checklist with the information from the Industry Code of Practice on Indoor Air Quality would provide easily comprehensible information and practical support. Intervention and evaluation studies using this newly developed IAQ checklist will clarify the effectiveness of a new approach in evaluating the risk of indoor air pollutants in the workplace. PMID:22570579
Syazwan, Ai; Rafee, B Mohd; Hafizan, Juahir; Azman, Azf; Nizar, Am; Izwyn, Z; Muhaimin, Aa; Yunos, Ma Syafiq; Anita, Ar; Hanafiah, J Muhamad; Shaharuddin, Ms; Ibthisham, A Mohd; Ismail, Mohd Hasmadi; Azhar, Mn Mohamad; Azizan, Hs; Zulfadhli, I; Othman, J
2012-01-01
To meet the current diversified health needs in workplaces, especially in nonindustrial workplaces in developing countries, an indoor air quality (IAQ) component of a participatory occupational safety and health survey should be included. The purpose of this study was to evaluate and suggest a multidisciplinary, integrated IAQ checklist for evaluating the health risk of building occupants. This IAQ checklist proposed to support employers, workers, and assessors in understanding a wide range of important elements in the indoor air environment to promote awareness in nonindustrial workplaces. The general structure of and specific items in the IAQ checklist were discussed in a focus group meeting with IAQ assessors based upon the result of a literature review, previous industrial code of practice, and previous interviews with company employers and workers. For practicality and validity, several sessions were held to elicit the opinions of company members, and, as a result, modifications were made. The newly developed IAQ checklist was finally formulated, consisting of seven core areas, nine technical areas, and 71 essential items. Each item was linked to a suitable section in the Industry Code of Practice on Indoor Air Quality published by the Department of Occupational Safety and Health. Combined usage of an IAQ checklist with the information from the Industry Code of Practice on Indoor Air Quality would provide easily comprehensible information and practical support. Intervention and evaluation studies using this newly developed IAQ checklist will clarify the effectiveness of a new approach in evaluating the risk of indoor air pollutants in the workplace.
Everett Jones, Sherry; Doroski, Brenda; Glick, Sherry
2015-12-01
Nationally representative data from the 2012 School Health Policies and Practices Study examined whether state assistance on indoor air quality (IAQ) was associated with district-level policies and practices related to IAQ and integrated pest management (IPM). Districts in states that provided assistance on IAQ were more likely than districts not in such states to (1) have an IAQ management program (p < .001); (2) require schools to conduct periodic inspections of the heating, ventilation, and air conditioning system (p < .05); of the building for cracks, leaks, or past water damage (p < .01); for mold (p < .01); for clutter that prevents effective cleaning and maintenance (p < .05); of the plumbing system (p < .01); and for condensation in and around school facilities (p < .001); (3) have an engine idling reduction program ( < .001); (4) have a policy to purchase low-emitting products (p < .05); and (5) require IPM strategies (p < .05). Increasing the number of states that provide IAQ-related assistance to school districts and schools may improve school IAQ. © The Author(s) 2015.
Indoor Air Quality and Student Performance [and Case Studies].
ERIC Educational Resources Information Center
Environmental Protection Agency, Washington, DC. Office of Radiation and Indoor Air.
This report examines how indoor air quality (IAQ) affects a child's ability to learn and provides several case studies of schools that have successfully addressed their indoor air problems, the lessons learned from that experience, and what long-term practices and policies emerged from the effort. The report covers the effects from…
Science Laboratories and Indoor Air Quality in Schools. Technical Bulletin.
ERIC Educational Resources Information Center
Jacobs, Bruce W.
Some of the issues surrounding the indoor air quality (IAQ) problems presented by science labs are discussed. Described are possible contaminants in labs, such as chemicals and biological organisms, and ways to lessen accidents arising from these sources are suggested. Some of the factors contributing to comfort, such as temperature levels, are…
INVESTIGATION OF CONTACT VACUUMING FOR REMEDIATION OF FUNGALLY CONTAMINATED DUCT MATERIALS
Environmental fungi become a potential Indoor Air Quality (IAQ) problem when adequate moisture and nutrients are present in building materials. Because of their potential to rapidly spread contamination throughout a building, ventilation system materials are of particular signifi...
Basic Information about the Indoor Air Quality Tribal Partners Program
IAQ Tribal Partners Program. This website aims to further empower champions of healthy IAQ in tribal communities with tools for networking, sharing programs and practices, and by serving as a reservoir of the best available tribal-specific IAQ information.
Mudarri, David H
2014-05-01
While a number of studies have addressed the economic cost associated with adverse health and productivity effects of poor indoor air quality (IAQ), few have addressed the value of economic expenditures and job creation associated with this industry. This article estimates that the annual sale of IAQ products and services is valued at $18-$30 billion and is associated with approximately 150,000-250,000 current jobs. Compared with other familiar industries, the IAQ market remains relatively small. Given the close association between good IAQ and both job performance of adults and learning performance of children, however, the expenditure to maintain good IAQ in commercial and educational facilities is a useful complement to programs designed to improve education and economic growth.
Regulation and its role in the prevention of building-associated illness.
Besch, E L
1989-01-01
Many groups have as their common goal the maintenance of acceptable indoor air quality, which protects occupants from adverse health effects and discomfort, but no one group possesses the interest or expertise to deal with all of the IAQ issues. Nonetheless, conclusions can be made regarding available alternatives to mitigate indoor air quality problems, including building-associated illness. It has been suggested that congressional action is needed in three areas related to BAI and IAQ: Recognition that controlling outdoor air only--even if "health based"--will not result in substantial improvement of public health; Definition of responsibilities for achieving healthful indoor environments; and Resolution of jurisdictional disputes between various federal agencies. Through their studies of buildings whose occupants complained of building-associated illness, NIOSH and others have concluded that inadequate supply and distribution of outdoor air to indoor spaces are the most common causes of SBS. Nonetheless, there are no reports of follow-up studies which confirm that the recommended ventilation upgrades actually solved the IAQ problems. Other reports indicate that maintenance, energy management, and air distribution are as important as ventilation rate. Corrective action, therefore, should include these issues. Systematic research directed toward providing cost-effective and innovative solutions should be the driving force. Rather than regulation, governments should assist in funding the necessary research, providing educational, technical and legal assistance, and developing policy options directed at reducing indoor air pollutants. In those cases where the specific causes of IAQ problems can be identified, remedial actions should be immediately implemented utilizing available technology. It has been suggested that "sick buildings" resulted from too much emphasis on efficency and safety and not enough on occupant health and well-being. Because health has been defined as "a state of complete physical, mental and social well-being not merely the absence of disease or infirmity," greater emphasis should be given to the concept of control and maintenance of healthy indoor environments (i.e., "healthy buildings") through utilization of quality assurance measures. Also, human response, system performance, and service factors should be utilized to assure an acceptable building performance. Finally, building designers, contractors, owners, managers, and operators must be knowledgeable regarding indoor air quality problems and their consequences and work together to build and maintain healthy buildings. This includes developing training, education, monitoring, and preventive maintenance programs to assure accountability for the proper management of the building systems. The certification (or licensing) of those responsible for providing indoor air quality has been suggested.
School environment as predictor of teacher sick leave: data-linked prospective cohort study
2012-01-01
Background Poor indoor air quality (IAQ) and psychosocial problems are common in schools worldwide, yet longitudinal research on the issue is scarce. We examined whether the level of or a change in pupil-reported school environment (IAQ, school satisfaction, and bullying) predicts recorded sick leaves among teachers. Methods Changes in the school environment were assessed using pupil surveys at two time points (2001/02 and 2004/05) in 92 secondary schools in Finland. Variables indicating change were based on median values at baseline. We linked these data to individual-level records of teachers’ (n = 1678) sick leaves in 2001–02 and in 2004–05. Results Multilevel multinomial logistic regression models adjusted for baseline sick leave and covariates showed a decreased risk for short-term (one to three days) sick leaves among teachers working in schools with good perceived IAQ at both times (OR = 0.6, 95% CI: 0.5-0.9), and for those with a positive change in IAQ (OR = 0.6, 95% CI: 0.4-0.9), compared to teachers in schools where IAQ was constantly poor. Negative changes in pupil school satisfaction (OR = 1.8, 95% CI: 1.1-2.8) and bullying (OR = 1.5, 95% CI: 1.0-2.3) increased the risk for short-term leaves among teachers when compared to teachers in schools where the level of satisfaction and bullying had remained stable. School environment factors were not associated with long-term sick leaves. Conclusions Good and improved IAQ are associated with decreased teacher absenteeism. While pupil-related psychosocial factors also contribute to sick leaves, no effect modification or mediation of psychosocial factors on the association between IAQ and sick leave was observed. PMID:22966903
School environment as predictor of teacher sick leave: data-linked prospective cohort study.
Ervasti, Jenni; Kivimäki, Mika; Kawachi, Ichiro; Subramanian, S V; Pentti, Jaana; Oksanen, Tuula; Puusniekka, Riikka; Pohjonen, Tiina; Vahtera, Jussi; Virtanen, Marianna
2012-09-11
Poor indoor air quality (IAQ) and psychosocial problems are common in schools worldwide, yet longitudinal research on the issue is scarce. We examined whether the level of or a change in pupil-reported school environment (IAQ, school satisfaction, and bullying) predicts recorded sick leaves among teachers. Changes in the school environment were assessed using pupil surveys at two time points (2001/02 and 2004/05) in 92 secondary schools in Finland. Variables indicating change were based on median values at baseline. We linked these data to individual-level records of teachers' (n = 1678) sick leaves in 2001-02 and in 2004-05. Multilevel multinomial logistic regression models adjusted for baseline sick leave and covariates showed a decreased risk for short-term (one to three days) sick leaves among teachers working in schools with good perceived IAQ at both times (OR = 0.6, 95% CI: 0.5-0.9), and for those with a positive change in IAQ (OR = 0.6, 95% CI: 0.4-0.9), compared to teachers in schools where IAQ was constantly poor. Negative changes in pupil school satisfaction (OR = 1.8, 95% CI: 1.1-2.8) and bullying (OR = 1.5, 95% CI: 1.0-2.3) increased the risk for short-term leaves among teachers when compared to teachers in schools where the level of satisfaction and bullying had remained stable. School environment factors were not associated with long-term sick leaves. Good and improved IAQ are associated with decreased teacher absenteeism. While pupil-related psychosocial factors also contribute to sick leaves, no effect modification or mediation of psychosocial factors on the association between IAQ and sick leave was observed.
INDOOR AIR QUALITY AND INHALATION EXPOSURE - SIMULATION TOOL KIT
A Microsoft Windows-based indoor air quality (IAQ) simulation software package is presented. Named Simulation Tool Kit for Indoor Air Quality and Inhalation Exposure, or IAQX for short, this package complements and supplements existing IAQ simulation programs and is desi...
Bugs in Your Rugs? Carpet Maintenance and Indoor Air Quality.
ERIC Educational Resources Information Center
Schmidt, Edward A.
1994-01-01
This article, the second in a three-part series of articles that discuss indoor air quality (IAQ) issues affecting schools, looks at the effects of carpet maintenance and environmental influences on IAQ. (MLF)
Working with the Media on Tribal Indoor Air Quality Issues
Working with the media can be beneficial in publicizing your indoor air quality (IAQ) messages and getting the word out about any activities or events that raise awareness about IAQ in your community.
Lin, Shao; Kielb, Christine L; Reddy, Amanda L; Chapman, Bonnie R; Hwang, Syni-An
2012-03-01
Good school indoor air quality (IAQ) can affect the health and functioning of school occupants. Thus, it is important to assess the degree to which schools and districts employ strategies to ensure good IAQ management. We examined and compared the patterns of IAQ management strategies between public elementary schools and their school districts in New York State. District-level information obtained from surveys of district facilities managers in 326 districts was described and stratified by district size and socioeconomic status. School-level information obtained from surveys of head custodians in 770 elementary schools was then compared with the district-level information in 241 districts. About 47% of participating school districts reported having a district-wide IAQ program, with a large range in the prevalence of specific IAQ management strategies. Airing out newly painted areas was the most commonly reported (92%) and having a classroom animal policy was the least commonly reported (29%). Larger districts and districts with a district-wide IAQ program were more likely to report certain IAQ strategies than other districts. Elementary schools and their districts were most likely to report airing out newly painted areas (76%). The most common area of disagreement was construction after hours (50%). The top strategy not reported at either level was having an IAQ coordinator (53%). Many school districts lack key IAQ management strategies, and differences exist between district-level policy and school-level practice. Districts and schools should work together to formalize and expand existing IAQ policies and inform stakeholders about these strategies. © 2012, American School Health Association.
Prevalence and Implementation of IAQ Programs in U.S. Schools
Moglia, Dena; Smith, Alisa; MacIntosh, David L.; Somers, Jennifer L.
2006-01-01
In this study, we determined the extent to which U.S. schools are implementing indoor air quality (IAQ) programs. We administered a questionnaire on IAQ programs and practices to a representative sample of schools. Participants were asked to provide information on the use, administration, implementation, challenges, and benefits of the IAQ program in their school. We developed an IAQ Practice Index to determine the level of activity directed toward IAQ in schools. The index was computed based on responses to specific survey questions and was normalized to a range of 0 to 100. Each question was weighted qualitatively according to its contribution to strong IAQ management practices. Forty-two percent of schools in the United States have an IAQ management program, and there has been sustained growth from 1998 through 2002 in the number of schools that have such programs. Nearly half of those schools use the U.S. Environmental Protection Agency’s IAQ Tools for Schools program. The IAQ Practice Index scores varied widely for schools with an IAQ management program, suggesting that having a program is not equivalent to implementing effective IAQ policies and procedures. Respondents indicated that their IAQ programs led to improved workplace satisfaction, fewer asthma attacks, fewer visits to the school nurse, and lower absenteeism. When actively supported by the school administration, an IAQ program appears to be a valuable factor in improving the learning environment for U.S. schoolchildren. PMID:16393672
Prevalence and implementation of IAQ programs in U.S. schools.
Moglia, Dena; Smith, Alisa; MacIntosh, David L; Somers, Jennifer L
2006-01-01
In this study, we determined the extent to which U.S. schools are implementing indoor air quality (IAQ) programs. We administered a questionnaire on IAQ programs and practices to a representative sample of schools. Participants were asked to provide information on the use, administration, implementation, challenges, and benefits of the IAQ program in their school. We developed an IAQ Practice Index to determine the level of activity directed toward IAQ in schools. The index was computed based on responses to specific survey questions and was normalized to a range of 0 to 100. Each question was weighted qualitatively according to its contribution to strong IAQ management practices. Forty-two percent of schools in the United States have an IAQ management program, and there has been sustained growth from 1998 through 2002 in the number of schools that have such programs. Nearly half of those schools use the U.S. Environmental Protection Agency's IAQ Tools for Schools program. The IAQ Practice Index scores varied widely for schools with an IAQ management program, suggesting that having a program is not equivalent to implementing effective IAQ policies and procedures. Respondents indicated that their IAQ programs led to improved workplace satisfaction, fewer asthma attacks, fewer visits to the school nurse, and lower absenteeism. When actively supported by the school administration, an IAQ program appears to be a valuable factor in improving the learning environment for U.S. schoolchildren.
AIRBORNE PARTICLE SIZES AND SOURCES FOUND IN INDOOR AIR
As concern about indoor air quality (IAQ) has grown in recent years, understanding indoor aerosols has become increasingly important so that control techniques may be implemented to reduce damaging health effects and soiling problems. This paper begins with a brief look at the me...
A smart indoor air quality sensor network
NASA Astrophysics Data System (ADS)
Wen, Jin
2006-03-01
The indoor air quality (IAQ) has an important impact on public health. Currently, the indoor air pollution, caused by gas, particle, and bio-aerosol pollutants, is considered as the top five environmental risks to public health and has an estimated cost of $2 billion/year due to medical cost and lost productivity. Furthermore, current buildings are especially vulnerable for chemical and biological warfare (CBW) agent contamination because the central air conditioning and ventilation system serve as a nature carrier to spread the released agent from one location to the whole indoor environment within a short time period. To assure the IAQ and safety for either new or existing buildings, real time comprehensive IAQ and CBW measurements are needed. With the development of new sensing technologies, economic and reliable comprehensive IAQ and CBW sensors become promising. However, few studies exist that examine the design and evaluation issues related to IAQ and CBW sensor network. In this paper, relevant research areas including IAQ and CBW sensor development, demand control ventilation, indoor CBW sensor system design, and sensor system design for other areas such as water system protection, fault detection and diagnosis, are reviewed and summarized. Potential research opportunities for IAQ and CBW sensor system design and evaluation are discussed.
Mainka, Anna; Zajusz-Zubek, Elwira
2015-07-08
Indoor air quality (IAQ) in preschools is an important public health challenge. Particular attention should be paid to younger children, because they are more vulnerable to air pollution than higher grade children and because they spend more time indoors. Among air pollutants, particulate matter (PM) is of the greatest interest mainly due to its acute and chronic effects on children's health. In addition, carbon dioxide (CO2) levels indicate ventilation conditions. In this paper, we present the concentrations of PM (PM1, PM2.5, PM10 and total-TSP) and CO2 monitored in four naturally ventilated nursery schools located in the area of Gliwice, Poland. The nursery schools were selected to characterize areas with different degrees of urbanization and traffic densities during the winter season. The results indicate the problem of elevated concentrations of PM inside the examined classrooms, as well as that of high levels of CO2 exceeding 1000 ppm in relation to outdoor air. The characteristics of IAQ were significantly different, both in terms of classroom occupation (younger or older children) and of localization (urban or rural). To evaluate the children's exposure to poor IAQ, indicators based on air quality guidelines were proposed to rank classrooms according to their hazard on the health of children.
Mainka, Anna; Zajusz-Zubek, Elwira
2015-01-01
Indoor air quality (IAQ) in preschools is an important public health challenge. Particular attention should be paid to younger children, because they are more vulnerable to air pollution than higher grade children and because they spend more time indoors. Among air pollutants, particulate matter (PM) is of the greatest interest mainly due to its acute and chronic effects on children’s health. In addition, carbon dioxide (CO2) levels indicate ventilation conditions. In this paper, we present the concentrations of PM (PM1, PM2.5, PM10 and total—TSP) and CO2 monitored in four naturally ventilated nursery schools located in the area of Gliwice, Poland. The nursery schools were selected to characterize areas with different degrees of urbanization and traffic densities during the winter season. The results indicate the problem of elevated concentrations of PM inside the examined classrooms, as well as that of high levels of CO2 exceeding 1000 ppm in relation to outdoor air. The characteristics of IAQ were significantly different, both in terms of classroom occupation (younger or older children) and of localization (urban or rural). To evaluate the children’s exposure to poor IAQ, indicators based on air quality guidelines were proposed to rank classrooms according to their hazard on the health of children. PMID:26184249
SIMULATION TOOL KIT FOR INDOOR AIR QUALITY AND INHALATION EXPOSURE (IAQX) VERSION 1.0 USER'S GUIDE
The User's Guide describes a Microsoft Windows-based indoor air quality (IAQ) simulation software package designed Simulation Tool Kit for Indoor Air Quality and Inhalation Exposure, or IAQX for short. This software complements and supplements existing IAQ simulation programs and...
ERIC Educational Resources Information Center
Adams, Cameron
2007-01-01
As the green movement grows, studies provide conclusive evidence about the benefits of environmentally conscious practices indoors and outdoors. Schools are no exception. Many of these studies demonstrate how poor indoor air quality (IAQ) in schools adversely affects many of the nation's 55 million students with health problems such as asthma and…
ERIC Educational Resources Information Center
Malcolm, Judith
Asserting that in Maine and across the nation, school buildings are becoming increasingly plagued with indoor air quality (IAQ) problems which contribute to a variety of illnesses in children and adults, this report from a Maine state legislative task force identifies appropriate policies and identifies actions necessary for the prevention and…
ERIC Educational Resources Information Center
Mahoney, Daniel P.
2008-01-01
Healthful indoor air quality (IAQ) in education facilities can improve the learning environment for students, enhance teacher job satisfaction, and reduce staff complaints. A proactive indoor air quality program helps identify and eliminate conditions that could lead to IAQ complaints, building-related illnesses, and workers' compensation claims.…
Improving Indoor Air Quality in St. Cloud Schools.
ERIC Educational Resources Information Center
Forer, Mike; Haus, El
2000-01-01
Describes how the St. Cloud Area School District (Minnesota), using Tools for Schools provided by the U.S. Environmental Protection Agency, managed the improvement of their school building indoor air quality (IAQ). The district goals of the IAQ Management Committee and the policy elements used to maintain high classroom air quality are…
National Gas Cool Times, September/October 2000.
ERIC Educational Resources Information Center
Natural Gas Cool Times, 2000
2000-01-01
Several articles are presented covering the development and use of gas/electric cooling solutions for public schools and colleges. Articles address financing issues; indoor air quality (IAQ) problems and solutions; and the analysis of heating, ventilation, and air conditioning systems. Three examples of how schools solved their cooling problems…
The report defines a simplified methodology that can be used by indoor air quality (IAQ) diagnosticians, architects/engineers, building owners/operators, and the scientific community for preliminary comparison of the cost-effectiveness of alternative IAQ control measures for any ...
Xiong, Youyou; Krogmann, Uta; Mainelis, Gediminas; Rodenburg, Lisa A; Andrews, Clinton J
2015-01-01
Improved indoor air quality (IAQ) is one of the critical components of green building design. Green building tax credit (e.g., New York State Green Building Tax Credit (GBTC)) and certification programs (e.g., Leadership in Energy & Environmental Design (LEED)) require indoor air quality measures and compliance with allowable maximum concentrations of common indoor air pollutants. It is not yet entirely clear whether compliance with these programs results in improved IAQ and ultimately human health. As a case in point, annual indoor air quality measurements were conducted in a residential green high-rise building for five consecutive years by an industrial hygiene contractor to comply with the building's GBTC requirements. The implementation of green design measures resulted in better IAQ compared to data in references of conventional homes for some parameters, but could not be confirmed for others. Relative humidity and carbon dioxide were satisfactory according to existing standards. Formaldehyde levels during four out of five years were below the most recent proposed exposure limits found in the literature. To some degree, particulate matter (PM) levels were lower than that in studies from conventional residential buildings. Concentrations of Volatile Organic Compounds (VOCs) with known permissible exposure limits were below levels known to cause chronic health effects, but their concentrations were inconclusive regarding cancer health effects due to relatively high detection limits. Although measured indoor air parameters met all IAQ maximum allowable concentrations in GBTC and applicable LEED requirements at the time of sampling, we argue that these measurements were not sufficient to assess IAQ comprehensively because more sensitive sampling/analytical methods for PM and VOCs are needed; in addition, there is a need for a formal process to ensure rigor and adequacy of sampling and analysis methods. Also, we suggest that a comprehensive IAQ assessment should include mixed mode thermal comfort models, semi-volatile organic compounds, assessment of new chemicals, and permissible exposure levels of many known indoor VOCs and bioaerosols. Plus, the relationship between energy consumption and IAQ, and tenant education on health effects of indoor pollutants and their sources may need more attention in IAQ investigations in green buildings.
Improving the indoor air quality of respiratory type of medical facility by zeolite filtering.
Shen, Jyun-Hong; Wang, Yeoung-Sheng; Lin, Jhan-Ping; Wu, Sheng-Hung; Horng, Jao-Jia
2014-01-01
This study investigated the indoor air quality (IAQ) conditions of carbon dioxide (CO2), carbon monoxide (CO), ozone (O3), formaldehyde (HCHO), total volatile organic compounds (TVOCs), and bio-aerosols (bacteria and fungi) in a respiratory type of medical facility in Chia-Yi County in southern Taiwan. Among those IAQ conditions, the concentrations of CO, O3, and HCHO exceeded the regulation values of the Taiwan Environmental Protection Administration (EPA) mostly in the morning. The concentrations of bacteria and fungi did not exceed the regulation values but still posed potential health and environment problems for workers, patients, and visitors. Therefore, self-made silver-coated zeolite (AgZ) was used as a filter material in air cleaners to remove bio-aerosols in the respiratory care ward (RCW), and the removals were still effective after 120 hr. The cumulative bio-aerosol removals for bacteria and fungi were 900 and 1,088 colony-forming units (CFU) g(-1) after 24 hr and were above 3,100 and 2,700 CFU g(-1) after 120 hr. From the research results, it is suggested that AgZ filtering could be used as a feasible engineering measure for hospitals to control their bacteria and fungi parameters in IAQ management. Hospitals should maintain their environmental management and monitoring programs and use different engineering measures to improve different IAQ parameters. This study investigated the IAQ conditions in the field at a hospital in Chia-Yi County in southern Taiwan. Although concentrations of most parameters were still within the regulation values, the concentrations of CO, O3, and HCHO were partially exceeded. We propose a method using an air cleaner with silver-coated zeolite (AgZ) as a possible engineering measure, and there were effective reductions of bacteria and fungi to lower levels with antibacterial effects after 120 hr. Furthermore, this study implies that hospitals should continuously maintain environmental monitoring programs and adopt optimal engineering measures for different needs.
School Indoor Air Quality Assessment and Program Implementation.
ERIC Educational Resources Information Center
Prill, R.; Blake, D.; Hales, D.
This paper describes the effectiveness of a three-step indoor air quality (IAQ) program implemented by 156 schools in the states of Washington and Idaho during the 2000-2001 school year. An experienced IAQ/building science specialist conducted walk-through assessments at each school. These assessments documented deficiencies and served as an…
Carpet and Indoor Air Quality in Schools. Technical Bulletin.
ERIC Educational Resources Information Center
Maryland State Dept. of Education, Baltimore.
Ways in which carpeting can affect a school's indoor air quality (IAQ) are discussed. Carpeting is defined as a system of components that includes pads, adhesives, floor preparation compounds, and seam sealers. For the last several years, these products have been increasingly scrutinized as to how they affect IAQ. Carpeting gives off volatile…
VERIFICATION AND USES OF THE ENVIRONMENTAL PROTECTION AGENCY (EPA) INDOOR AIR QUALITY MODEL
The paper describes a set of experiments used to verify an indoor air quality (IAQ) model for estimating the impact of various pollution sources on IAQ in a multiroom building. he model treats each room as a well-mixed chamber that contains pollution sources and sinks. he model a...
[Index assessment of airborne VOCs pollution in automobile for transporting passengers].
Chen, Xiao-Kai; Cheng, He-Ming; Luo, Hui-Long
2013-12-01
Car for transporting passenger is the most common means of transport and in-car airborne volatile organic compounds (VOCs) cause harm to health. In order to analyze the pollution levels of benzene, toluene, ethylbenzene, xylenes, styrene and TVOC, index evaluation method was used according to the domestic and international standards of indoor and in-car air quality (IAQ). For Chinese GB/T 18883-2002 IAQ Standard, GB/T 17729-2009 Hygienic Standard for the Air Quality inside Long Distance Coach, GB/T 27630-2011 Guideline for Air Quality Assessment of Passenger Car, IAQ standard of South Korea, Norway, Japan and Germany, the heaviest pollution of VOCs in passenger car was TVOC, TVOC, benzene, benzene, TVOC, toluene and TVOC, respectively, the average pollution grade of automotive IAQ was median pollution, median pollution, clean, light pollution, median pollution, clean and heavy pollution, respectively. Index evaluation can effectively analyze vehicular interior air quality, and the result has a significant difference with different standards; German standard is the most stringent, while Chinese GB/T 18883-2002 standard is the relatively stringent and GB/T 27630-2011 is the most relaxed.
Indoor Air Quality Tools for Tribal Communities
This Website can help you improve IAQ in your tribal community. You can find information to educate your community about the simple actions they can take to improve their IAQ and protect their health.
Teachers and Healthy Indoor School Environments
Teachers can be powerful advocates for creating healthy indoor environments, including improving school indoor air quality (IAQ). As they are on the front lines, teachers can perceive when IAQ changes affect students and themselves.
Tribal Indoor Air Quality Programs in the Spotlight
The following tribal IAQ champions graciously shared their stories so that others can better serve their communities. Read on to learn how these stellar programs overcame challenges to form successful IAQ initiatives.
Indoor Air Quality in Tribal Communities
This Website can help you improve IAQ in your tribal community. You can find information to educate your community about the simple actions they can take to improve their IAQ and protect their health.
NASA Astrophysics Data System (ADS)
Garg, Abhinav; Ghosh, Chirashree
Today, one of the most grave environmental health problems being faced by the urban population is the poor air quality one breathes in. To testify the above statement, the recent survey report, World health statistics (WHO, 2012) reflects the fact that childhood mortality ratio from acute respiratory infection is one of the top leading causes of death in developing countries like India. Urban areas have a complex social stratification which ultimately results in forming different urban economic zones. This research attempts to understand the Indoor Air Quality (IAQ) by taking into consideration different lifestyle of occupants inhabiting these economic zones. The Study tries to evaluate the outdoor and indoor air quality by understanding the variation of selected pollutants (SPM, SOx, NOx) for the duration of four months - from October, 2012-January, 2013. For this, three economic zones (EZ) of Delhi University’s North Campus, were selected - Urban Slum (EZ I), Clerical (EZ II) and Faculty residence (EZ III). The statistical study indicates that Urban Slum (EZ I) was the most polluted site reporting maximum concentration of outdoor pollutants, whereas no significant difference in pollution load was observed in EZ II and EZ III. Further, the indoor air quality was evaluated by quantifying the indoor and outdoor pollution concentration ratios that shows EZ III have most inferior indoor air quality, followed by EZ I and EZ II. Moreover, it was also observed that ratio (phenomenon of infiltration) was dominant at the EZ II but was low for the EZ I and EZ III. With the evidence of high Indoor air pollution, the risk of pulmonary diseases and respiratory infections also increases, calling for an urgent requisite for making reforms to improve IAQ. Key words: Urban Area, Slum, IAQ, SOx, NOx, SPM
[Enclosed environments and health].
Maroni, M; Barbieri, F
1989-01-01
Problems related to Indoor Air Quality are subject of study since about twenty years. New architectural criteria, new building materials and increasing demands of energy saving have progressively changed residences, offices and all non-industrial indoor environments. This paper present a review of the IAQ-related issues from sources characterization, to pollutant assessment and definition of effects on human health.
Chemicals in Classrooms. Pesticides and Maintenance Chemicals in Vermont Schools.
ERIC Educational Resources Information Center
Sterling, Peter; Browning, Brigid
This report is the second in a series of studies on the serious threat toxic chemical use may pose to the health of Vermont's children, teachers, and school staff. The first report, "Toxic Chemical Exposure in Schools: Our Children at Risk," provided an overview of the problem of poor indoor air quality (IAQ) in schools and discussed…
ERIC Educational Resources Information Center
Frank, David
This brief describes the findings of a consortium on indoor air quality (IAQ) in educational facilities held in Chattanooga, Tennessee. The objective was to determine the impact floorcoverings have on indoor air quality in schools relative to maintenance, volatile organic compounds (VOCs), airborne contaminants, moisture, surface contaminants, and…
NASA Astrophysics Data System (ADS)
Saad, S. M.; Shakaff, A. Y. M.; Saad, A. R. M.; Yusof, A. M.; Andrew, A. M.; Zakaria, A.; Adom, A. H.
2017-03-01
There are various sources influencing indoor air quality (IAQ) which could emit dangerous gases such as carbon monoxide (CO), carbon dioxide (CO2), ozone (O3) and particulate matter. These gases are usually safe for us to breathe in if they are emitted in safe quantity but if the amount of these gases exceeded the safe level, they might be hazardous to human being especially children and people with asthmatic problem. Therefore, a smart indoor air quality monitoring system (IAQMS) is needed that able to tell the occupants about which sources that trigger the indoor air pollution. In this project, an IAQMS that able to classify sources influencing IAQ has been developed. This IAQMS applies a classification method based on Probabilistic Neural Network (PNN). It is used to classify the sources of indoor air pollution based on five conditions: ambient air, human activity, presence of chemical products, presence of food and beverage, and presence of fragrance. In order to get good and best classification accuracy, an analysis of several feature selection based on data pre-processing method is done to discriminate among the sources. The output from each data pre-processing method has been used as the input for the neural network. The result shows that PNN analysis with the data pre-processing method give good classification accuracy of 99.89% and able to classify the sources influencing IAQ high classification rate.
Kielb, C; Lin, S; Muscatiello, N; Hord, W; Rogers-Harrington, J; Healy, J
2015-08-01
Most previous research on indoor environments and health has studied school children or occupants in non-school settings. This investigation assessed building-related health symptoms and classroom characteristics via telephone survey of New York State school teachers. Participants were asked about 14 building-related symptoms and 23 classroom characteristics potentially related to poor indoor air quality (IAQ). Poisson regression analysis was used to assess the relationship between these symptoms and each classroom characteristic, controlling for potential confounders. About 500 teachers completed the survey. The most frequently reported classroom characteristics included open shelving (70.7%), food eaten in class (65.5%), dust (59.1%), and carpeting (46.9%). The most commonly reported symptoms included sinus problems (16.8%), headache (15.0%), allergies/congestion (14.8%), and throat irritation (14.6%). Experiencing one or more symptoms was associated most strongly with reported dust (relative risk (RR) = 3.67; 95% confidence interval (CI): 2.62-5.13), dust reservoirs (RR = 2.13; 95% CI: 1.72-2.65), paint odors (RR = 1.73; 95% CI: 1.40-2.13), mold (RR = 1.71; 95% CI: 1.39-2.11), and moldy odors (RR = 1.65 95% CI: 1.30-2.10). Stronger associations were found with increasing numbers of reported IAQ-related classroom characteristics. Similar results were found with having any building-related allergic/respiratory symptom. This research adds to the body of evidence underscoring the importance to occupant health of school IAQ. Teachers play an important role in educating children, and teacher well-being is important to this role. Health symptoms among New York teachers while at work are common and appear to be associated with numerous characteristics related to poor classroom IAQ. Improving school Indoor Air Quality may reduce sickness and absenteeism and improve teacher performance. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Frey, Sarah E.
Americans spend upwards of 90% of their time indoors, hence indoor air quality (IAQ) and the impact of IAQ on human health is a major public health concern. IAQ can be negatively impacted by outdoor pollution infiltrating indoors, the emission of indoor pollutants, indoor atmospheric chemistry and poor ventilation. Energy saving measures like retrofits to seal the building envelope to prevent the leakage of heated or cooled air will impact IAQ. However, existing studies have been inconclusive as to whether increased energy efficiency is leading to detrimental IAQ. In this work, field campaigns were conducted in apartment homes in Phoenix, Arizona to evaluate IAQ as it relates to particulate matter (PM), carbonyls, and tobacco specific nitrosamines (TSNA). To investigate the impacts of an energy efficiency retrofit on IAQ, indoor and outdoor air quality sampling was carried out at Sunnyslope Manor, a city-subsidized senior living apartment complex. Measured indoor formaldehyde levels before the building retrofit exceeded reference exposure limits, but in the long term follow-up sampling, indoor formaldehyde decreased for the entire study population by a statistically significant margin. Indoor PM levels were dominated by fine particles and showed a statistically significant decrease in the long term follow-up sampling within certain resident subpopulations (i.e. residents who reported smoking and residents who had lived longer at the apartment complex). Additionally, indoor glyoxal and methylglyoxal exceeded outdoor concentrations, with methylglyoxal being more prevalent pre-retrofit than glyoxal, suggesting different chemical pathways are involved. Indoor concentrations reported are larger than previous studies. TSNAs, specifically N'-nitrosonornicotine (NNN), 4-(methyl-nitrosamino)-4-(3-pyridyl)-butanal (NNA) and 4-(methylnitrosoamino)-1-(3-pyridyl)-1-butanone (NNK) were evaluated post-retrofit at Sunnyslope Manor. Of the units tested, 86% of the smoking units and 46% of the non-smoking units had traces of at least one of the nitrosamines.
ERIC Educational Resources Information Center
Wheeler, Arthur E.
To help maintain good indoor air quality (IAQ) in schools, guidance for the development and implementation of an effective program for maintenance and operation of heating, ventilating, and air-conditioning (HVAC) systems are discussed. Frequently, a building's occupants will complain about IAQ when the temperature or humidity are at uncomfortable…
Indoor air quality levels in a University Hospital in the Eastern Province of Saudi Arabia
El-Sharkawy, Mahmoud F.; Noweir, Mohamed E. H.
2014-01-01
Aim of the Study: The complex hospital environment requires special attention to ensure a healthy indoor air quality (IAQ) to protect patients and healthcare workers against hospital-acquired infections and occupational diseases. Poor hospital IAQ may cause outbreaks of building-related illness such as headaches, fatigue, eye, and skin irritations, and other symptoms. The general objective for this study was to assess IAQ inside a large University hospital at Al-Khobar City in the Eastern Province of Saudi Arabia. Materials and Methods: Different locations representing areas where most activities and tasks are performed were selected as sampling points for air pollutants in the selected hospital. In addition, several factors were studied to determine those that were most likely to affect the IAQ levels. The temperature and relative percent humidity of different air pollutants were measured simultaneously at each location. Results: The outdoor levels of all air pollutant levels, except volatile organic compounds (VOCs), were higher than the indoor levels which meant that the IAQ inside healthcare facilities (HCFs) were greatly affected by outdoor sources, particularly traffic. The highest levels of total suspended particulates (TSPs) and those less than 10 microns (PM10) inside the selected hospital were found at locations that are characterized with m4ore human activity. Conclusions: Levels of particulate matter (both PM10 and TSP) were higher than the Air Quality Guidelines (AQGs). The highest concentrations of the fungal species recorded were Cladosporium and Penicillium. Education of occupants of HCF on IAQ is critical. They must be informed about the sources and effects of contaminants and the proper operation of the ventilation system. PMID:24696632
ERIC Educational Resources Information Center
Schultz, Fred C.
2001-01-01
Reveals how seeking simplicity can help bring indoor air quality (IAQ) solutions to grade schools by balancing IAQ needs, cost, and energy. Issues involving ventilation rate requirements are reexamined, as are compliance with outside-air requirements, dealing with variable-air-volume air distribution regulators, and retrofitting issues involving…
Learn more about the special construction scheduling/sequencing requirements and procedures necessary to assure achievement of designed Indoor Air Quality (IAQ) levels for the completed project required by the EPA IAQ Program.
ERIC Educational Resources Information Center
Wilson, Scott
2001-01-01
Highlights the different design approaches that may be taken and the HVAC systems that result depending on the type of educational facility involved, be it an elementary, secondary, or postsecondary institution. Explores school indoor air quality issues and highlights the roles and responsibilities of IAQ project participants. A case study…
Web Information Systems for Monitoring and Control of Indoor Air Quality at Subway Stations
NASA Astrophysics Data System (ADS)
Choi, Gi Heung; Choi, Gi Sang; Jang, Joo Hyoung
In crowded subway stations indoor air quality (IAQ) is a key factor for ensuring the safety, health and comfort of passengers. In this study, a framework for web-based information system in VDN environment for monitoring and control of IAQ in subway stations is suggested. Since physical variables that describing IAQ need to be closely monitored and controlled in multiple locations in subway stations, concept of distributed monitoring and control network using wireless media needs to be implemented. Connecting remote wireless sensor network and device (LonWorks) networks to the IP network based on the concept of VDN can provide a powerful, integrated, distributed monitoring and control performance, making a web-based information system possible.
Indoor Air Quality in 24 California Residences Designed as High-Performance Homes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Less, Brennan; Mullen, Nasim; Singer, Brett
2015-07-01
Today’s high performance green homes are reaching previously unheard of levels of airtightness and are using new materials, technologies and strategies, whose impacts on Indoor Air Quality (IAQ) cannot be fully anticipated from prior studies. This research study used pollutant measurements, home inspections, diagnostic testing and occupant surveys to assess IAQ in 24 new or deeply retrofitted homes designed to be high performance green buildings in California.
Air change rates (ACRs) and interzonal flows are key determinants of indoor air quality (IAQ) and building energy use. This paper characterizes ACRs and interzonal flows in 126 houses, and evaluates effects of these parameters on IAQ. ACRs measured using weeklong tracer measureme...
Air Quality and Indoor Environmental Exposures: Clinical ...
Indoor air quality (IAQ) is a term which refers to the air quality within and around buildings and homes as it relates to the health and comfort of the occupants. Many ambient (outdoor) air pollutants readily permeate indoor spaces. Because indoor air can be considerably more polluted than ambient air, the USEPA lists poor IAQ as a major environmental concern. In the sections that follow, health effects associated with commonly encountered ambient air pollutants and indoor contaminants will be broken down by agent class. In some cases, exposure may be acute, with one or more pets (and owners) experiencing signs within a relatively short period. However, most exposures are episodic or chronic, making it difficult to definitively link poor IAQ to respiratory or other adverse health outcomes. Age or underlying immunologic, cardiac, or respiratory disease may further complicate the clinical picture, as those patients may be more sensitive to (and affected by) lower concentrations than prove problematic for healthy housemates. Because pets, like their owners, spend most of their lives indoors, we will discuss how certain home conditions can worsen indoor air quality and will briefly discuss measures to improve IAQ for owners and their pets. In this overview presentation, health effects associated with commonly encountered ambient air pollutants and indoor contaminants will be broken down by agent class. Because pets, like their owners, spend most of their lives indoo
Indoor Air Quality Assessment of the San Francisco Federal Building
DOE Office of Scientific and Technical Information (OSTI.GOV)
Apte, Michael; Bennett, Deborah H.; Faulkner, David
2008-07-01
An assessment of the indoor air quality (IAQ) of the San Francisco Federal Building (SFFB) was conducted on May 12 and 14, 2009 at the request of the General Services Administration (GSA). The purpose of the assessment was for a general screening of IAQ parameters typically indicative of well functioning building systems. One naturally ventilated space and one mechanically ventilated space were studied. In both zones, the levels of indoor air contaminants, including CO2, CO, particulate matter, volatile organic compounds, and aldehydes, were low, relative to reference exposure levels and air quality standards for comparable office buildings. We found slightlymore » elevated levels of volatile organic compounds (VOCs) including two compounds often found in"green" cleaning products. In addition, we found two industrial solvents at levels higher than typically seen in office buildings, but the levels were not sufficient to be of a health concern. The ventilation rates in the two study spaces were high by any standard. Ventilation rates in the building should be further investigated and adjusted to be in line with the building design. Based on our measurements, we conclude that the IAQ is satisfactory in the zone we tested, but IAQ may need to be re-checked after the ventilation rates have been lowered.« less
Indoor air quality (IAQ) evaluation of a Novel Tobacco Vapor (NTV) product.
Ichitsubo, Hirokazu; Kotaki, Misato
2018-02-01
The impact of using a Novel Tobacco Vapor (NTV) product on indoor air quality (IAQ) was simulated using an environmentally-controlled chamber. Three environmental simulations were examined; two non-smoking areas (conference room and dining room) and one ventilated smoking area (smoking lounge). IAQ was evaluated by (i) measuring constituents in the mainstream NTV product emissions, (ii) and by determining classical environmental tobacco smoke (ETS) and representative air quality markers. Analysis of the mainstream emissions revealed that vapor from the NTV product is chemically simpler than cigarette smoke. ETS markers (RSP, UVPM, FPM, solanesol, nicotine, 3-ethenylpyridine), volatile organic compound (toluene), carbon monoxide, propylene glycol, glycerol, and triacetin were below the limit of detection or the limit of quantification in both the non-smoking and smoking environments after using the NTV product. The concentrations of ammonia, carbonyls (formaldehyde, acetaldehyde, and acetone), and total volatile organic compounds were the same levels found in the chamber without NTV use. There was no significant increase in the levels of formaldehyde, acetone or ammonia in exhaled breath following NTV use. In summary, under the simulations tested, the NTV product had no measurable effect on the IAQ, in either non-smoking or smoking areas. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Field and Laboratory Testing of Approaches to Smart Whole-House Mechanical Ventilation Control
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, Eric; Fenaughty, Karen; Parker, Danny
Whole-house mechanical ventilation is a critical component to a comprehensive strategy for good indoor air quality (IAQ). However, due to lack of integration with standard heating and cooling systems, and perceptions from a portion of the homebuilding industry about risks related to increased energy use, increased cost, and decreased comfort, voluntary and code-required adoption varies among regions. Smart ventilation controls (SVC) balance energy consumption, comfort, and IAQ by optimizing mechanical ventilation operation to reduce the heating and/or cooling loads, improve management of indoor moisture, and maintain IAQ equivalence according to ASHRAE 62.2.
Field and Laboratory Testing of Approaches to Smart Whole-House Mechanical Ventilation Control
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, Eric; Fenaughty, Karen; Parker, Danny
Whole-house mechanical ventilation is a critical component to a comprehensive strategy for good indoor air quality (IAQ). However, due to lack of integration with standard heating and cooling systems, and perceptions from a portion of the homebuilding industry about risks related to increased energy use, increased cost, and decreased comfort, voluntary and code-required adoption varies amongst regions. Smart ventilation controls (SVC) balance energy consumption, comfort, and IAQ by optimizing mechanical ventilation operation to reduce the heating and/or cooling loads, improve management of indoor moisture, and maintain IAQ equivalence according to ASHRAE 62.2.
Morgan, Heather; Treasure, Elizabeth; Tabib, Mo; Johnston, Majella; Dunkley, Chris; Ritchie, Deborah; Semple, Sean; Turner, Steve
2016-10-12
Maternal smoking can cause health complications in pregnancy. Particulate matter (PM 2.5 ) metrics applied to second hand smoke (SHS) concentrations provide indoor air quality (IAQ) measurements and have been used to promote smoking behaviour change among parents of young children. Here, we present the qualitative results from a study designed to use IAQ measurements to help pregnant women who smoke to quit smoking. We used IAQ measurements in two centres (Aberdeen and Coventry) using two interventions: 1. In Aberdeen, women made IAQ measurements in their homes following routine ultrasound scan; 2. In Coventry, IAQ measurements were added to a home-based Stop Smoking in Pregnancy Service. All women were invited to give a qualitative interview to explore acceptability and feasibility of IAQ measurements to help with smoking cessation. A case study approach using grounded theory was applied to develop a typology of pregnant women who smoke. There were 39 women recruited (18 in Aberdeen and 21 in Coventry) and qualitative interviews were undertaken with nine of those women. Diverse accounts of smoking behaviours and experiences of participation were given. Many women reported changes to their smoking behaviours during pregnancy. Most women wanted to make further changes to their own behaviour, but could not commit or felt constrained by living with a partner or family members who smoked. Others could not envisage quitting. Using themes emerging from the interviews, we constructed a typology where women were classified as follows: 'champions for change'; 'keen, but not committed'; and 'can't quit, won't quit'. Three women reported quitting smoking alongside participation in our study. Pregnant women who smoke remain hard to engage,. Although providing IAQ measurements does not obviously improve quit rates, it can support changes in smoking behaviour in/around the home for some individuals. Our typology might offer a useful assessment tool for midwives.
The IAQ Tools for Schools Walkthrough Video: Four Schools Making a Difference. [Videotape].
ERIC Educational Resources Information Center
Environmental Protection Agency, Washington, DC.
This video illustrates one of the key components of the Environmental Protection Agency's "Indoor Air Quality Tools for Schools" (IAQ TfS) process--the school walkthrough. Videotaped at a North Carolina school built in 1999, hosts Keith Flippen and Debra Terry describe what schools in Nebraska, Massachusetts, Connecticut, and Iowa found…
Bearg, D W
1998-09-01
This article summarizes an approach for improving the indoor air quality (IAQ) in a building by providing feedback on the performance of the ventilation system. The delivery of adequate quantities of ventilation to all building occupants is necessary for the achievement of good IAQ. Feedback on the performance includes information on the adequacy of ventilation provided, the effectiveness of the distribution of this air, the adequacy of the duration of operation of the ventilation system, and the identification of leakage into the return plenum, either of outdoor or supply air. Keeping track of ventilation system performance is important not only in terms of maintaining good IAQ, but also making sure that this system continues to perform as intended after changes in building use. Information on the performance of the ventilation system is achieved by means of an automated sampling system that draws air from multiple locations and delivers it to both a carbon dioxide monitor and dew point sensor. The use of single shared sensors facilitates calibration checks as well as helps to guarantee data integrity. This approach to monitoring a building's ventilation system offers the possibility of achieving sustainable performance of this important aspect of good IAQ.
Simplified tools for evaluating domestic ventilation systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maansson, L.G.; Orme, M.
1999-07-01
Within an International Energy Agency (IEA) project, Annex 27, experts from 8 countries (Canada, France, Italy, Japan, The Netherlands, Sweden, UK and USA) have developed simplified tools for evaluating domestic ventilation systems during the heating season. Tools for building and user aspects, thermal comfort, noise, energy, life cycle cost, reliability and indoor air quality (IAQ) have been devised. The results can be used both for dwellings at the design stage and after construction. The tools lead to immediate answers and indications about the consequences of different choices that may arise during discussion with clients. This paper presents an introduction tomore » these tools. Examples applications of the indoor air quality and energy simplified tools are also provided. The IAQ tool accounts for constant emission sources, CO{sub 2}, cooking products, tobacco smoke, condensation risks, humidity levels (i.e., for judging the risk for mould and house dust mites), and pressure difference (for identifying the risk for radon or land fill spillage entering the dwelling or problems with indoor combustion appliances). An elaborated set of design parameters were worked out that resulted in about 17,000 combinations. By using multi-variate analysis it was possible to reduce this to 174 combinations for IAQ. In addition, a sensitivity analysis was made using 990 combinations. The results from all the runs were used to develop a simplified tool, as well as quantifying equations relying on the design parameters. A computerized energy tool has also been developed within this project, which takes into account air tightness, climate, window airing pattern, outdoor air flow rate and heat exchange efficiency.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Apte, Michael G.
Two devices, an occupational carbon monoxide (CO) dosimeter (LOCD), and an indoor air quality (IAQ) passive sampler were developed for use in population-based CO exposure assessment studies. CO exposure is a serious public health problem in the U.S., causing both morbidity and mortality (lifetime mortality risk approximately 10{sup -4}). Sparse data from population-based CO exposure assessments indicate that approximately 10% of the U.S. population is exposed to CO above the national ambient air quality standard. No CO exposure measurement technology is presently available for affordable population-based CO exposure assessment studies. The LOCD and IAQ Passive Sampler were tested in themore » laboratory and field. The palladium-molybdenum based CO sensor was designed into a compact diffusion tube sampler that can be worn. Time-weighted-average (TWA) CO exposure of the device is quantified by a simple spectrophotometric measurement. The LOCD and IAQ Passive Sampler were tested over an exposure range of 40 to 700 ppm-hours and 200 to 4200 ppm-hours, respectively. Both devices were capable of measuring precisely (relative standard deviation <20%), with low bias (<10%). The LOCD was screened for interferences by temperature, humidity, and organic and inorganic gases. Temperature effects were small in the range of 10°C to 30°C. Humidity effects were low between 20% and 90% RH. Ethylene (200 ppm) caused a positive interference and nitric oxide (50 ppm) caused a negative response without the presence of CO but not with CO.« less
Scheepers, Paul T J; Van Wel, Luuk; Beckmann, Gwendolyn; Anzion, Rob B M
2017-05-08
For healthcare centers, local outdoor sources of air pollution represent a potential threat to indoor air quality (IAQ). The aim of this study was to study the impact of local outdoor sources of air pollution on the IAQ of a university hospital. IAQ was characterized at thirteen indoor and two outdoor locations and source samples were collected from a helicopter and an emergency power supply. Volatile organic compounds (VOC), acrolein, formaldehyde, nitrogen dioxide (NO₂), respirable particulate matter (PM-4.0 and PM-2.5) and their respective benz(a)pyrene contents were determined over a period of two weeks. Time-weighted average concentrations of NO₂ (4.9-17.4 μg/m³) and formaldehyde (2.5-6.4 μg/m³) were similar on all indoor and outdoor locations. The median concentration VOC in indoor air was 119 μg/m³ (range: 33.1-2450 μg/m³) and was fivefold higher in laboratories (316 μg/m³) compared to offices (57.0 μg/m³). PM-4.0 and benzo(a)pyrene concentration were lower in buildings serviced by a >99.95% efficiency particle filter, compared to buildings using a standard 80-90% efficiency filter ( p < 0.01). No indications were found that support a significant contribution of known local sources such as fuels or combustion engines to any of the IAQ parameters measured in this study. Chemical IAQ was primarily driven by known indoor sources and activities.
[Air quality control systems: heating, ventilating, and air conditioning (HVAC)].
Bellucci Sessa, R; Riccio, G
2004-01-01
After a brief illustration of the principal layout schemes of Heating, Ventilating, and Air Conditioning (HVAC), the first part of this paper summarizes the standards, both voluntary and compulsory, regulating HVAC facilities design and installation with regard to the question of Indoor Air Quality (IAQ). The paper then examines the problem of ventilation systems maintenance and the essential hygienistic requirements in whose absence HVAC facilities may become a risk factor for people working or living in the building. Lastly, the paper deals with HVAC design strategies and methods, which aim not only to satisfy comfort and air quality requirements, but also to ensure easy and effective maintenance procedures.
Indoor air humidity, air quality, and health - An overview.
Wolkoff, Peder
2018-04-01
There is a long-standing dispute about indoor air humidity and perceived indoor air quality (IAQ) and associated health effects. Complaints about sensory irritation in eyes and upper airways are generally among top-two symptoms together with the perception "dry air" in office environments. This calls for an integrated analysis of indoor air humidity and eye and airway health effects. This overview has reviewed the literature about the effects of extended exposure to low humidity on perceived IAQ, sensory irritation symptoms in eyes and airways, work performance, sleep quality, virus survival, and voice disruption. Elevation of the indoor air humidity may positively impact perceived IAQ, eye symptomatology, and possibly work performance in the office environment; however, mice inhalation studies do not show exacerbation of sensory irritation in the airways by low humidity. Elevated humidified indoor air appears to reduce nasal symptoms in patients suffering from obstructive apnea syndrome, while no clear improvement on voice production has been identified, except for those with vocal fatigue. Both low and high RH, and perhaps even better absolute humidity (water vapor), favors transmission and survival of influenza virus in many studies, but the relationship between temperature, humidity, and the virus and aerosol dynamics is complex, which in the end depends on the individual virus type and its physical/chemical properties. Dry and humid air perception continues to be reported in offices and in residential areas, despite the IAQ parameter "dry air" (or "wet/humid air") is semantically misleading, because a sensory organ for humidity is non-existing in humans. This IAQ parameter appears to reflect different perceptions among other odor, dustiness, and possibly exacerbated by desiccation effect of low air humidity. It is salient to distinguish between indoor air humidity (relative or absolute) near the breathing and ocular zone and phenomena caused by moisture-damage of the building construction and emissions therefrom. Further, residential versus public environments should be considered as separate entities with different characteristics and demands of humidity. Research is needed about particle, bacteria and virus dynamics indoors for improvement of quality of life and with more focus on the impact of absolute humidity. "Dry (or wet) air" should be redefined to become a meaningful IAQ descriptor. Copyright © 2018 The Author. Published by Elsevier GmbH.. All rights reserved.
Resolving the ambiguities: An industrial hygiene Indoor Air Quality (IAQ) symposium
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gammage, R.B.
1995-01-01
Resolving the Ambiguities: An Industrial Hygiene (IAQ) Symposium was a one-day event designed to inform practicing industrial hygienists about highlight presentations made at Indoor Air `93. A broad range of topics was presented by invited speakers. Topics included were attempts to deal with guidelines and standards, questionnaires, odors and sensory irritation, respiratory allergies, neuroses, sick building syndrome (SBS), and multiple chemical sensitivity (MCS).
Investigation of air pollutants in rural nursery school - a case study
NASA Astrophysics Data System (ADS)
Mainka, Anna; Zajusz-Zubek, Elwira; Kozielska, Barbara; Brągoszewska, Ewa
2018-01-01
Children's exposure to air pollutants is an important public health challenge. Indoor air quality (IAQ) in nursery school is believed to be different from elementary school. Moreover, younger children are more vulnerable to air pollution than higher grade children because they spend more time indoors, and their immune systems and bodies are less mature. The purpose of this study was to evaluate the indoor air quality (IAQ) at naturally ventilated rural nursery schools located in Upper Silesia, Poland. We investigated the concentrations of volatile organic compounds (VOCs), particulate matter (PM), bacterial and fungal bioaerosols, as well as carbon dioxide (CO2) concentrations in younger and older children's classrooms during the winter and spring seasons. The concentration of the investigated pollutants in indoor environments was higher than those in outdoor air. The results indicate the problem of elevated concentrations of PM2.5 and PM10 inside the examined classrooms, as well as that of high levels of CO2 exceeding 1,000 ppm in relation to outdoor air. The characteristics of PM and CO2 levels were significantly different, both in terms of classroom occupation (younger or older children) and of season (winter or spring).
Scheepers, Paul T. J.; Van Wel, Luuk; Beckmann, Gwendolyn; Anzion, Rob B. M.
2017-01-01
For healthcare centers, local outdoor sources of air pollution represent a potential threat to indoor air quality (IAQ). The aim of this study was to study the impact of local outdoor sources of air pollution on the IAQ of a university hospital. IAQ was characterized at thirteen indoor and two outdoor locations and source samples were collected from a helicopter and an emergency power supply. Volatile organic compounds (VOC), acrolein, formaldehyde, nitrogen dioxide (NO2), respirable particulate matter (PM-4.0 and PM-2.5) and their respective benz(a)pyrene contents were determined over a period of two weeks. Time-weighted average concentrations of NO2 (4.9–17.4 μg/m3) and formaldehyde (2.5–6.4 μg/m3) were similar on all indoor and outdoor locations. The median concentration VOC in indoor air was 119 μg/m3 (range: 33.1–2450 μg/m3) and was fivefold higher in laboratories (316 μg/m3) compared to offices (57.0 μg/m3). PM-4.0 and benzo(a)pyrene concentration were lower in buildings serviced by a >99.95% efficiency particle filter, compared to buildings using a standard 80–90% efficiency filter (p < 0.01). No indications were found that support a significant contribution of known local sources such as fuels or combustion engines to any of the IAQ parameters measured in this study. Chemical IAQ was primarily driven by known indoor sources and activities. PMID:28481324
2015-08-19
laboratory analysis using EPA TO-15, and collection of gas samples in sorbent tubes for later analysis of aldehydes using NIOSH Method 2016. Total VOCs...measurement can be a general qualitative indicator of IAQ problems; formaldehyde and other aldehydes are common organic gases emitted from OSB; and...table in the middle of the hut. 5.1.2.3 Formaldehyde and other aldehydes Aldehydes were measured using both Dräger-tubes and by NIOSH Method 2016. The
Indoor air quality in 24 California residences designed as high-performance homes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Less, Brennan; Mullen, Nasim; Singer, Brett
2015-01-01
Today’s high performance green homes are reaching previously unheard of levels of airtightness and are using new materials, technologies and strategies, whose impacts on Indoor Air Quality (IAQ) cannot be fully anticipated from prior studies. This research study used pollutant measurements, home inspections, diagnostic testing and occupant surveys to assess IAQ in 24 new or deeply retrofitted homes designed to be high performance green buildings in California. Although the mechanically vented homes were six times as airtight as non-mechanically ventilated homes (medians of 1.1 and 6.1 ACH 50, n=11 and n=8, respectively), their use of mechanical ventilation systems and possiblymore » window operation meant their median air exchange rates were almost the same (0.30 versus 0.32 hr -1, n=8 and n=8, respectively). Pollutant levels were also similar in vented and unvented homes. In addition, these similarities were achieved despite numerous observed faults in complex mechanical ventilation systems. More rigorous commissioning is still recommended. Cooking exhaust systems were used inconsistently and several suffered from design flaws. Failure to follow best practices led to IAQ problems in some cases. Ambient nitrogen dioxide standards were exceeded or nearly so in four homes that either used gas ranges with standing pilots, or in Passive House-style homes that used gas cooking burners without venting range hoods. Homes without active particle filtration had particle count concentrations approximately double those in homes with enhanced filtration. The majority of homes reported using low-emitting materials; consistent with this, formaldehyde levels were approximately half those in conventional, new CA homes built before 2008. Emissions of ultrafine particles (with diameters <100 nm) were dramatically lower on induction electric cooktops, compared with either gas or resistance electric models. These results indicate that high performance homes can achieve acceptable and even exceptional IAQ by providing adequate general mechanical ventilation, using low-emitting materials, providing mechanical particle filtration, incorporating well-designed exhaust ventilation for kitchens and bathrooms, and educating occupants to use the kitchen and bath ventilation.« less
Towards the Application of Fuzzy Logic for Developing a Novel Indoor Air Quality Index (FIAQI).
Javid, Allahbakhsh; Hamedian, Amir Abbas; Gharibi, Hamed; Sowlat, Mohammad Hossein
2016-02-01
In the past few decades, Indoor Air Pollution (IAP) has become a primary concern to the point. It is increasingly believed to be of equal or greater importance to human health compared to ambient air. However, due to the lack of comprehensive indices for the integrated assessment of indoor air quality (IAQ), we aimed to develop a novel, Fuzzy-Based Indoor Air Quality Index (FIAQI) to bridge the existing gap in this area. We based our index on fuzzy logic, which enables us to overcome the limitations of traditional methods applied to develop environmental quality indices. Fifteen parameters, including the criteria air pollutants, volatile organic compounds, and bioaerosols were included in the FIAQI due mainly to their significant health effects. Weighting factors were assigned to the parameters based on the medical evidence available in the literature on their health effects. The final FIAQI consisted of 108 rules. In order to demonstrate the performance of the index, data were intentionally generated to cover a variety of quality levels. In addition, a sensitivity analysis was conducted to assess the validity of the index. The FIAQI tends to be a comprehensive tool to classify IAQ and produce accurate results. It seems useful and reliable to be considered by authorities to assess IAQ environments.
Towards the Application of Fuzzy Logic for Developing a Novel Indoor Air Quality Index (FIAQI)
JAVID, Allahbakhsh; HAMEDIAN, Amir Abbas; GHARIBI, Hamed; SOWLAT, Mohammad Hossein
2016-01-01
Background: In the past few decades, Indoor Air Pollution (IAP) has become a primary concern to the point. It is increasingly believed to be of equal or greater importance to human health compared to ambient air. However, due to the lack of comprehensive indices for the integrated assessment of indoor air quality (IAQ), we aimed to develop a novel, Fuzzy-Based Indoor Air Quality Index (FIAQI) to bridge the existing gap in this area. Methods: We based our index on fuzzy logic, which enables us to overcome the limitations of traditional methods applied to develop environmental quality indices. Fifteen parameters, including the criteria air pollutants, volatile organic compounds, and bioaerosols were included in the FIAQI due mainly to their significant health effects. Weighting factors were assigned to the parameters based on the medical evidence available in the literature on their health effects. The final FIAQI consisted of 108 rules. In order to demonstrate the performance of the index, data were intentionally generated to cover a variety of quality levels. In addition, a sensitivity analysis was conducted to assess the validity of the index. Results: The FIAQI tends to be a comprehensive tool to classify IAQ and produce accurate results. Conclusion: It seems useful and reliable to be considered by authorities to assess IAQ environments. PMID:27114985
Children's exposure to indoor air in urban nurseries-part I: CO₂ and comfort assessment.
Branco, P T B S; Alvim-Ferraz, M C M; Martins, F G; Sousa, S I V
2015-07-01
Indoor air quality (IAQ) in nurseries is an emerging case-study. Thus, this study, as the Part I of the larger study "Children's exposure to indoor air in urban nurseries", aimed to: i) evaluate nurseries' indoor concentrations of carbon dioxide (CO2), a global IAQ indicator, in class and lunch rooms; ii) assess indoor comfort parameters-temperature (T) and relative humidity (RH); and iii) analyse them according to guidelines and references for IAQ, comfort and children's health. Indoor continuous measurements were performed. Non-compliances with guidelines were found in comfort parameters, which could cause discomfort situations and also microbial proliferation. Exceedances in CO2 concentrations were also found and they were caused by poor ventilation and high classroom occupation. More efficient ventilation and control of comfort parameters, as well as to reduce occupation by reviewing Portuguese legislation on that matter, would certainly improve IAQ and comfort in nurseries and consequently safeguard children's health. Copyright © 2015 Elsevier Inc. All rights reserved.
Indoor Air Quality and Health.
Cincinelli, Alessandra; Martellini, Tania
2017-10-25
In the last few decades, Indoor Air Quality (IAQ) has received increasing attention from the international scientific community, political institutions, and environmental governances for improving the comfort, health, and wellbeing of building occupants.[...].
Indoor air quality in Portuguese schools: levels and sources of pollutants.
Madureira, J; Paciência, I; Pereira, C; Teixeira, J P; Fernandes, E de O
2016-08-01
Indoor air quality (IAQ) parameters in 73 primary classrooms in Porto were examined for the purpose of assessing levels of volatile organic compounds (VOCs), aldehydes, particulate matter, ventilation rates and bioaerosols within and between schools, and potential sources. Levels of VOCs, aldehydes, PM2.5 , PM10 , bacteria and fungi, carbon dioxide (CO2 ), carbon monoxide, temperature and relative humidity were measured indoors and outdoors and a walkthrough survey was performed concurrently. Ventilation rates were derived from CO2 and occupancy data. Concentrations of CO2 exceeding 1000 ppm were often encountered, indicating poor ventilation. Most VOCs had low concentrations (median of individual species <5 μg/m(3) ) and were below the respective WHO guidelines. Concentrations of particulate matter and culturable bacteria were frequently higher than guidelines/reference values. The variability of VOCs, aldehydes, bioaerosol concentrations, and CO2 levels between schools exceeded the variability within schools. These findings indicate that IAQ problems may persist in classrooms where pollutant sources exist and classrooms are poorly ventilated; source control strategies (related to building location, occupant behavior, maintenance/cleaning activities) are deemed to be the most reliable for the prevention of adverse health consequences in children in schools. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Technical Solutions to Common Indoor Air Quality Issues in Schools
Indoor Air Quality (IAQ) Design Tools for Schools provides voluntary guidance for school personnel, architects, engineers, builders and contractors, parents, and the community on key school construction and renovation issues.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Turner, William; Walker, Iain
One way to reduce the energy impact of providing residential ventilation is to use passive and hybrid systems. However, these passive and hybrid (sometimes called mixed-mode) systems must still meet chronic and acute health standards for ventilation. This study uses a computer simulation approach to examine the energy and indoor air quality (IAQ) implications of passive and hybrid ventilation systems, in 16 California climate zones. Both uncontrolled and flow controlled passive stacks are assessed. A new hybrid ventilation system is outlined that uses an intelligent ventilation controller to minimise energy use, while ensuring chronic and acute IAQ standards are met.more » ASHRAE Standard 62.2-2010 – the United States standard for residential ventilation - is used as the chronic standard, and exposure limits for PM 2.5, formaldehyde and NO 2 are used as the acute standards.The results show that controlled passive ventilation and hybrid ventilation can be used in homes to provide equivalent IAQ to continuous mechanical ventilation, for less use of energy.« less
Children's exposure to indoor air in urban nurseries-part I: CO{sub 2} and comfort assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Branco, P.T.B.S.; Alvim-Ferraz, M.C.M.; Martins, F.G.
2015-07-15
Indoor air quality (IAQ) in nurseries is an emerging case-study. Thus, this study, as the Part I of the larger study “Children's exposure to indoor air in urban nurseries”, aimed to: i) evaluate nurseries’ indoor concentrations of carbon dioxide (CO{sub 2}), a global IAQ indicator, in class and lunch rooms; ii) assess indoor comfort parameters–temperature (T) and relative humidity (RH); and iii) analyse them according to guidelines and references for IAQ, comfort and children's health. Indoor continuous measurements were performed. Non-compliances with guidelines were found in comfort parameters, which could cause discomfort situations and also microbial proliferation. Exceedances in CO{submore » 2} concentrations were also found and they were caused by poor ventilation and high classroom occupation. More efficient ventilation and control of comfort parameters, as well as to reduce occupation by reviewing Portuguese legislation on that matter, would certainly improve IAQ and comfort in nurseries and consequently safeguard children's health. - Highlights: • High occupation and poor ventilation were main determinants of IAQ in nurseries. • T and RH indoor values found in nurseries are likely to cause thermal discomfort. • Building characteristics and an inadequate ventilation determined T and RH values. • High CO{sub 2} concentrations found could indicate accumulation of other air pollutants.« less
Short-term airing by natural ventilation - implication on IAQ and thermal comfort.
Heiselberg, P; Perino, M
2010-04-01
The need to improve the energy efficiency of buildings requires new and more efficient ventilation systems. It has been demonstrated that innovative operating concepts that make use of natural ventilation seem to be more appreciated by occupants. Among the available ventilation strategies that are currently available, buoyancy driven, single-sided natural ventilation has proved to be very effective and can provide high air change rates for temperature and Indoor Air Quality (IAQ) control. However, to promote a wider distribution of these systems an improvement in the knowledge of their working principles is necessary. The present study analyses and presents the results of an experimental evaluation of airing performance in terms of ventilation characteristics, IAQ and thermal comfort. It includes investigations of the consequences of opening time, opening frequency, opening area and expected airflow rate, ventilation efficiency, thermal comfort and dynamic temperature conditions. A suitable laboratory test rig was developed to perform extensive experimental analyses of the phenomenon under controlled and repeatable conditions. The results showed that short-term window airing is very effective and can provide both acceptable IAQ and thermal comfort conditions in buildings. Practical Implications This study gives the necessary background and in-depth knowledge of the performance of window airing by single-sided natural ventilation necessary for the development of control strategies for window airing (length of opening period and opening frequency) for optimum IAQ and thermal comfort in naturally ventilated buildings.
Sofuoglu, S C; Moschandreas, D J
2003-12-01
The lack of an effective indoor air quality (IAQ) metric causes communication concerns among building tenants (the public), building managers (decision-makers), and IAQ investigators (engineers). The Indoor Air Pollution Index (IAPI) is developed for office buildings to bridge this communication discord. The index, simple and easily understood, employs the range of pollutant concentrations and concentrations in the subject building to estimate a unitless single number, the IAPI, between 0 (lowest pollution level and best IAQ) and ten (highest pollution level and worst IAQ). The index provides a relative measure of indoor air pollution for office buildings and ranks office indoor air pollution relative to the index distribution of the US office building population. Furthermore, the index associates well with occupant symptoms, percentage of occupants with persistent symptoms. A tree-structured method is utilized in conjunction with the arithmetic mean as the aggregation function. The hierarchical structure of the method renders not only one index value, but also several sub-index values that are critical in the study of an office air environment. The use of the IAPI for IAQ management is illustrated with an example. The decomposition of the index leads to the ranking of sampled pollutants by their relative contribution to the index and the identification of dominant pollutant(s). This information can be applied to design an effective strategy for reducing in-office air pollution.
Publications about Indoor Air Quality in Schools
Publications and resources that relate to indoor air quality in schools, and design tools for schools. These publications cover a wide range of issues, including IAQ management, student performance, asthma, mold and moisture, and radon.
Scheepers, Paul T J; de Hartog, Jeroen J; Reijnaerts, Judith; Beckmann, Gwendolyn; Anzion, Rob; Poels, Katrien; Godderis, Lode
2015-02-01
Primary schools mostly rely on natural ventilation but also have an interest in affordable technology to improve indoor air quality (IAQ). Laboratory tests show promising results for dust reducing carpets and compact air filtration systems but there is no information available on the performance of these interventions in actual operating classrooms. An exploratory study was performed to evaluate a combination of the two systems in a primary school. Measurements of PM-10 and PM-2.5 were performed by filter sampling and aerosol spectrometry. Other IAQ parameters included black smoke (BS), volatile organic compounds (VOC), nitrogen dioxide (NO2) and formaldehyde. Both interventions were introduced in one classroom during one week, using another classroom as a reference. In a second week the interventions were moved to the other classroom, using the first as a reference (cross-over design). In three remaining weeks the classrooms were compared without interventions. Indoor IAQ parameters were compared to the corresponding outdoor parameters using the indoor/outdoor (I/O) ratio. When the classrooms were occupied (teaching hours) interventions resulted in 27-43% reductions of PM-10, PM-2.5 and BS values. During the weekends the systems reduced these levels by 51-87%. Evaluations using the change in I/O ratios gave comparable results. Levels of VOC, NO2 and formaldehyde were rather low and a contribution of the interventions to the improvement of these gas phase IAQ parameters was inconclusive.
Singleton, Rosalyn; Salkoski, Aaron J.; Bulkow, Lisa; Fish, Chris; Dobson, Jennifer; Albertson, Leif; Skarada, Jennifer; Ritter, Troy; Kovesi, Thomas; Hennessy, Thomas W
2018-01-01
ABSTRACT Alaska Native children experience high rates of lower respiratory tract infections (LRTIs) and lung conditions, which are associated with substandard indoor air quality (IAQ). We conducted an intervention of home remediation and education to assess the impact on IAQ, respiratory symptoms and LRTI visits. We enrolled households of children 1–12 years of age with lung conditions. Home remediation included improving ventilation and replacing leaky woodstoves. We provided education about IAQ and respiratory health. We monitored indoor airborne particles (PM2.5), CO2, relative humidity and volatile organic compounds (VOCs), and interviewed caregivers about children’s symptoms before, and for 1 year after intervention. We evaluated the association between children’s respiratory visits, symptoms and IAQ indicators using multiple logistic regression. A total of 60 of 63 homes completed the study. VOCs decreased (coefficient = −0.20; p < 0.001); however, PM2.5 (coeff. = −0.010; p = 0.89) did not decrease. Burning wood for heat, VOCs and PM2.5 were associated with respiratory symptoms. After remediation, parents reported decreases in runny nose, cough between colds, wet cough, wheezing with colds, wheezing between colds and school absences. Children had an age-adjusted decrease in LRTI visits (coefficient = −0.33; p = 0.028). Home remediation and education reduced respiratory symptoms, LRTI visits and school absenteeism in children with lung conditions. PMID:29393004
Singleton, Rosalyn; Salkoski, Aaron J; Bulkow, Lisa; Fish, Chris; Dobson, Jennifer; Albertson, Leif; Skarada, Jennifer; Ritter, Troy; Kovesi, Thomas; Hennessy, Thomas W
2018-12-01
Alaska Native children experience high rates of lower respiratory tract infections (LRTIs) and lung conditions, which are associated with substandard indoor air quality (IAQ). We conducted an intervention of home remediation and education to assess the impact on IAQ, respiratory symptoms and LRTI visits. We enrolled households of children 1-12 years of age with lung conditions. Home remediation included improving ventilation and replacing leaky woodstoves. We provided education about IAQ and respiratory health. We monitored indoor airborne particles (PM2.5), CO 2 , relative humidity and volatile organic compounds (VOCs), and interviewed caregivers about children's symptoms before, and for 1 year after intervention. We evaluated the association between children's respiratory visits, symptoms and IAQ indicators using multiple logistic regression. A total of 60 of 63 homes completed the study. VOCs decreased (coefficient = -0.20; p < 0.001); however, PM2.5 (coeff. = -0.010; p = 0.89) did not decrease. Burning wood for heat, VOCs and PM2.5 were associated with respiratory symptoms. After remediation, parents reported decreases in runny nose, cough between colds, wet cough, wheezing with colds, wheezing between colds and school absences. Children had an age-adjusted decrease in LRTI visits (coefficient = -0.33; p = 0.028). Home remediation and education reduced respiratory symptoms, LRTI visits and school absenteeism in children with lung conditions.
[Thermal comfort and indoor air quality in some of the italian state police workplaces.
Chirico, Francesco; Rulli, Giuseppina
2017-12-01
Little can be found in the literature about thermal comfort and indoor air quality (IAQ) in law enforcement workplaces. This study, based on environmental surveys carried out by the Centro Sanitario Polifunzionale of Milan (Italian State Police Health Service Department), aims to assess the thermal comfort and IAQ in some of the Italian State Police workplaces. Measurements were performed in some indoor workplaces such as offices, archives, laboratories and guard-houses in various regions (Lombardia, Emilia Romagna, Liguria, Veneto, Trentino Alto-Adige) of Northern Italy. The PMV/PPD model developed by Fangar for the evaluation of the thermal comfort was used. We measured both CO2 concentration and relative humidity indoor levels for the evaluation of IAQ. We used Chi square and t Student tests to study both prevalence of thermal discomfort and low IAQ, and their differences between summer and winter. For the purposes of the present study we carried out 488 measurements in 36 buildings (260 in winter and 228 in summer). Our results showed that thermal comfort was reached in 95% and 68% of environmental measurements (in winter and summer, respectively). In summer, we measured different types of thermal discomfort. As regard to IAQ, CO2 exceeded the threshold limit value (1000 ppm) in 39% (winter) and 9% (summer) of our measurements. Chi-square test showed a statistically significant difference between summer and winter for all outcomes considered. Indeed, thermal comfort was better in winter than summer (X2 = 61.0795), while IAQ was found to be better in the summer than winter considering both the CO2 1000 ppm and 1200 ppm threshold values (X2 = 56.9004 and X2 = 8.8845 respectively). Prevalence of low relative humidity in winter was higher than in summer (X2 = 124.7764). Even though this study did not report any situation of risk to Italian police officers health and safety, it has highlighted some potential issues in some of the examined workplaces, concerning thermal comfort in summer and IAQ in winter. Regarding the risk assessment process, simple and inexpensive preventive measures are already feasible in the 'observation phase' of the risk assessment, before execution of instrumental environmental survey. According to the technical standards and risk assessment models, this way might increase both comfort levels for workers employed in indoor environments and the effectiveness of the risk assessment process, through the optimization of available resources. Copyright© by Aracne Editrice, Roma, Italy.
NASA Astrophysics Data System (ADS)
Mohddin, S. A.; Aminuddin, N. M.
2014-02-01
Airborne particulates have been recognized as a crucial pollutant of indoor air. These pollutants can contribute towards poor indoor air quality (IAQ), which may affect human health in immediate or long term. This study aims to determine the level of IAQ and the effects of particulate towards occupants of office buildings (the office buildings selected for the case study are SSM, KTMB and MRCB at KL Sentral). The objectives of study are (i) to measure the level of airborne particulates that contribute to the IAQ during working hours, (ii) to compare the level of airborne particulates with the existing guidelines and standards of IAQ in Malaysia and other Asian countries and (iii) to assess the symptoms associated with airborne particulates among the building occupants, which were achieved through primary data collection (case study or site survey, structured interview and questionnaire survey) and supported by literature reviews. The results showed that the mass concentration level of airborne particulates within the areas has exceeded the allowable limit of 0.15mg/m3 by IAQ Code of Practice, 2005 of the Department of Safety and Health (DOSH), Malaysia and 0.05mg/m3 by the Department of Environmental (DOE) (outdoor) of 8 hours continuous sampling. Based on the findings, the highest mass concentration values measured is 2.581 mg/m3 at lobby of SSM building which is the highest recorded 17 times higher from the maximum limit recommended by DOSH than the others. This is due to the nearby construction works and the high numbers of particulates are generated from various types of vehicles for transportation surrounding KL Sentral. Therefore, the development of Malaysian Ambient Air Quality Guidelines on PM2.5 as one of the crucial parameters is highly recommended.
What's Your IAQ? It Could Mean Your Health.
ERIC Educational Resources Information Center
Malone, Bobby G.; Cox, Edward P.
2002-01-01
Describes causes and health consequences of poor indoor air quality in schools; describes Office of Safety and Health Association and Environmental Protection Agency efforts to improve indoor air quality through the promulgation and enforcement of standards and regulations. (PKP)
Air Quality and Indoor Environmental Exposures: Clinical Impacts
Indoor air quality (IAQ) is a term which refers to the air quality within and around buildings and homes as it relates to the health and comfort of the occupants. Many ambient (outdoor) air pollutants readily permeate indoor spaces. Because indoor air can be considerably more pol...
The ORNL Indoor Air Quality Study: Re-cap, Context, and Assessment on Radon
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tonn, Bruce Edward; Rose, Erin M.; Ternes, Mark P.
As part of the retrospective evaluation of the U.S. Department of Energy s low-income Weatherization Assistance Program that was led by Oak Ridge National Laboratory (ORNL), an assessment of the impacts of weatherization on indoor air quality (IAQ) was conducted. This assessment included nearly 500 treatment and control homes across the country. Homes were monitored for carbon monoxide, radon, formaldehyde, temperature and humidity pre- and post-weatherization. This report focuses on the topic of radon and addresses issues not thoroughly discussed in the original IAQ report. The size, scope and rigor of the radon component of the IAQ study are comparedmore » to previous studies that assessed the impacts of weatherization on indoor radon levels. It is found that the ORNL study is by far the most extensive study conducted to date, though the ORNL results are consistent with the findings of the other studies. However, the study does have limitations related to its reliance on short-term measurements of radon and inability to attribute changes in radon levels in homes post-weatherization to specific weatherization measures individually or in combination.« less
Indoor air quality in an automotive assembly plant in Selangor, Malaysia.
Edimansyah, B A; Rusli, B N; Naing, L; Azwan, B A; Aziah, B D
2009-01-01
The purpose of this study was to determine the indoor air quality (IAQ) status of an automotive assembly plant in Rawang, Selangor, Malaysia using selected IAQ parameters, such as carbon dioxide (CO2), carbon monoxide (CO), temperature, relative humidity (RH) and respirable particulate matter (PM10). A cross-sectional study was conducted in the paint shop and body shop sections of the plant in March 2005. The Q-TRAK Plus IAQ Monitor was used to record the patterns of CO, CO2, RH and temperature; whilst PM10 was measured using DUSTTRAK Aerosol Monitor over an 8-hour time weight average (8-TWA). It was found that the average temperatures, RH and PM10 in the paint shop section and body shop sections exceeded the Department of Safety and Health (DOSH) standards. The average concentrations of RH and CO were slightly higher in the body shop section than in the paint shop section, while the average concentrations of temperature and CO2 were slightly higher in the paint shop section than in the body shop section. There was no difference in the average concentrations of PM10 between the two sections.
Spotlight on the Tribal Indoor Air Quality Summit Workgroup in Midwest Region 5
The Tribal IAQ Summit Workgroup uses a collaborative approach to increase the impact of tribes’ efforts to manage indoor air quality and improve community health for tribes in Illinois, Indiana, Michigan, Minnesota, Ohio and Wisconsin.
Environment and Health in Children Day Care Centres (ENVIRH) - Study rationale and protocol.
Araújo-Martins, J; Carreiro Martins, P; Viegas, J; Aelenei, D; Cano, M M; Teixeira, J P; Paixão, P; Papoila, A L; Leiria-Pinto, P; Pedro, C; Rosado-Pinto, J; Annesi-Maesano, I; Neuparth, N
2014-01-01
Indoor air quality (IAQ) is considered an important determinant of human health. The association between exposure to volatile organic compounds, particulate matter, house dust mite, molds and bacteria in day care centers (DCC) is not completely clear. The aim of this project was to study these effects. This study comprised two phases. Phase I included an evaluation of 45 DCCs (25 from Lisbon and 20 from Oporto, targeting 5161 children). In this phase, building characteristics, indoor CO2 and air temperature/relative humidity, were assessed. A children's respiratory health questionnaire derived from the ISAAC (International Study on Asthma and Allergies in Children) was also distributed. Phase II encompassed two evaluations and included 20 DCCs selected from phase I after a cluster analysis (11 from Lisbon and 9 from Oporto, targeting 2287 children). In this phase, data on ventilation, IAQ, thermal comfort parameters, respiratory and allergic health, airway inflammation biomarkers, respiratory virus infection patterns and parental and child stress were collected. In Phase I, building characteristics, occupant behavior and ventilation surrogates were collected from all DCCs. The response rate of the questionnaire was 61.7% (3186 children). Phase II included 1221 children. Association results between DCC characteristics, IAQ and health outcomes will be provided in order to support recommendations on IAQ and children's health. A building ventilation model will also be developed. This paper outlines methods that might be implemented by other investigators conducting studies on the association between respiratory health and indoor air quality at DCC. Copyright © 2013 Sociedade Portuguesa de Pneumologia. Published by Elsevier España. All rights reserved.
ERIC Educational Resources Information Center
Baldwin Union Free School District, NY.
This manual identifies ways to improve a school's indoor air quality (IAQ) and discusses practical actions that can be carried out by school staff in managing air quality. The manual includes discussions of the many sources contributing to school indoor air pollution and the preventive planning for each including renovation and repair work,…
Text Version of the Indoor Air Quality House Tour
Get a quick glimpse of some of the most important ways to protect the air in your home by touring the Indoor Air Quality (IAQ) House. Room-by-room, you'll learn about the key pollutants and how to address them.
HVAC SYSTEMS AS EMISSION SOURCES AFFECTING INDOOR AIR QUALITY: A CRITICAL REVIEW
The study evaluates heating, ventilating, and air-conditioning (HVAC) systems as contaminant emission sources that affect indoor air quality (IAQ). Various literature sources and methods for characterizing HVAC emission sources are reviewed. Available methods include in situ test...
A Guide to Lowering Test Scores.
ERIC Educational Resources Information Center
Rosenblum, Shelly; Spark, Barbara
2002-01-01
Discusses the adverse impact of poor classroom air quality on student performance and how school officials can eliminate the sources of indoor air pollution. Describes Environmental Protection Agency's "Indoor Air Quality Tools for Schools" program downloadable at www.epa.gov/iaq/schools/index.html. (PKP)
de Gennaro, Gianluigi; Dambruoso, Paolo Rosario; Di Gilio, Alessia; Di Palma, Valerio; Marzocca, Annalisa; Tutino, Maria
2015-12-24
Around 50% of the world's population, particularly in developing countries, uses biomass as one of the most common fuels. Biomass combustion releases a considerable amount of various incomplete combustion products, including particulate matter (PM) and polycyclic aromatic hydrocarbons (PAHs). The paper presents the results of Indoor Air Quality (IAQ) measurements in six houses equipped with wood burning stoves or fireplaces as heating systems. The houses were monitored for 48-h periods in order to collect PM10 samples and measure PAH concentrations. The average, the maximum and the lowest values of the 12-h PM10 concentration were 68.6 μg/m³, 350.7 μg/m³ and 16.8 μg/m³ respectively. The average benzo[a]pyrene 12-h concentration was 9.4 ng/m³, while the maximum and the minimum values were 24.0 ng/m³ and 1.5 ng/m³, respectively. Continuous monitoring of PM10, PAHs, Ultra Fine Particle (UFP) and Total Volatile Organic Compounds (TVOC) was performed in order to study the progress of pollution phenomena due to biomass burning, their trends and contributions to IAQ. The results show a great heterogeneity of impacts on IAQ in terms of magnitude and behavior of the considered pollutants' concentrations. This variability is determined by not only different combustion technologies or biomass quality, but overall by different ignition mode, feeding and flame management, which can also be different for the same house. Moreover, room dimensions and ventilation were significant factors for pollution dispersion. The increase of PM10, UFP and PAH concentrations, during lighting, was always detected and relevant. Continuous monitoring allowed singling out contributions of other domestic sources of considered pollutants such as cooking and cigarettes. Cooking contribution produced an impact on IAQ in same cases higher than that of the biomass heating system.
A page to register to view the May 17, 2018, webinar in the IAQ Knowledge-to-Action Professional Training Webinar Series: Clean Air in the Classroom: Improve Air Quality, Extend HVAC System Life with Preventive Maintenance
School Solutions. Special Report: IAQ and Energy.
ERIC Educational Resources Information Center
Birr, Dave
1999-01-01
Discusses how energy service companies (ESCO) can help schools upgrade their indoor air quality and make them environmentally sound. How ESCO's help in arranging funding for indoor environmental improvements through energy performance contracts is discussed. Tips on energy-efficiency measures for improving indoor environmental quality are…
HVAC SYSTEMS AS EMISSION SOURCES AFFECTING INDOOR AIR QUALITY: A CRITICAL REVIEW
The paper discusses results of an evaluation of literature on heating, ventilating, and air-conditioning (HVAC) systems as contaminant emission sources that affect indoor air quality (IAQ). The various literature sources and methods for characterizing HVAC emission sources are re...
Improving IAQ Via Air Filtration.
ERIC Educational Resources Information Center
Monk, Brian
1999-01-01
Provides tips on using air filtration to control indoor air quality in educational facilities, including dedicated spaces with unique air quality conditions such as in libraries, museums and archival storage areas, kitchens and dining areas, and laboratories. The control of particulate contaminants, gaseous contaminants, and moisture buildup are…
BIOWALL’S IMPACT ON INDOOR AIR QUALITY AND ENERGY
This project will collect data on air quality and energy consumption for a variety of Biowall configurations in a controlled laboratory environment. This data will be evaluated for statistical significance and used to develop and validate an energy/IAQ model of the Bi...
Indoor Air Quality in Schools (IAQ): The Importance of Monitoring Carbon Dioxide Levels.
ERIC Educational Resources Information Center
Sundersingh, David; Bearg, David W.
This article highlights indoor air quality and exposure to pollutants at school. Typical air pollutants within schools include environmental tobacco smoke, formaldehyde, volatile organic compounds, nitrogen oxides, carbon monoxide, carbon dioxide, allergens, pathogens, radon, pesticides, lead, and dust. Inadequate ventilation, inefficient…
Comfort, Indoor Air Quality, and Energy Consumption in Low Energy Homes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Englemann, P.; Roth, K.; Tiefenbeck, V.
2013-01-01
This report documents the results of an in-depth evaluation of energy consumption and thermal comfort for two potential net zero-energy homes (NZEHs) in Massachusetts, as well as an indoor air quality (IAQ) evaluation performed in conjunction with Lawrence Berkeley National Laboratory (LBNL).
Bristowe, Katherine; Patrick, Peter L
2014-12-01
To explore use of 'Invitations to Ask Questions' (IAQs) by plastic surgeons in outpatient consultations, and consider how type of IAQ impacts on patients' responses to, and recollection of, IAQs. Descriptive study: 63 patients were audio recorded in consultation with 5 plastic surgeons, and completed a brief questionnaire immediately after the consultation. Consultation transcripts were analyzed using inductive qualitative methods of Discourse Analysis and compared with questionnaire findings. A taxonomy of IAQs was developed, including three types of IAQ (Overt, Covert, and Borderline). Overt IAQs were rarely identified, and almost all IAQs occurred in the closing stages of the consultation. However, when an overt IAQ was used, patients always recollected being asked if they had any questions after the consultation. Patients are rarely explicitly offered the opportunity to ask questions. When this does occur, it is often in the closing stages of the consultation. Clinicians should openly encourage patients to ask questions frequently throughout the consultation, and be mindful that subtle differences in construction of these utterances may impact upon interpretation. Clear communication, of message and intention, is essential in clinical encounters to minimize misunderstanding, misinterpretation, or missed opportunities for patients to raise concerns. Copyright © 2014. Published by Elsevier Ireland Ltd.
Dutton, S M; Mendell, M J; Chan, W R; Barrios, M; Sidheswaran, M A; Sullivan, D P; Eliseeva, E A; Fisk, W J
2015-02-01
This research assesses benefits of adding to California Title-24 ventilation rate (VR) standards a performance-based option, similar to the American Society of Heating, Refrigerating, and Air Conditioning Engineers 'Indoor Air Quality Procedure' (IAQP) for retail spaces. Ventilation rates and concentrations of contaminants of concern (CoC) were measured in 13 stores. Mass balance models were used to estimate 'IAQP-based' VRs that would maintain concentrations of all CoCs below health- or odor-based reference concentration limits. An intervention study in a 'big box' store assessed how the current VR, the Title 24-prescribed VR, and the IAQP-based VR (0.24, 0.69, and 1.51 air changes per hour) influenced measured IAQ and perceived of IAQ. Neither current VRs nor Title 24-prescribed VRs would maintain all CoCs below reference limits in 12 of 13 stores. In the big box store, the IAQP-based VR kept all CoCs below limits. More than 80% of subjects reported acceptable air quality at all three VRs. In 11 of 13 buildings, saving energy through lower VRs while maintaining acceptable IAQ would require source reduction or gas-phase air cleaning for CoCs. In only one of the 13 retail stores surveyed, application of the IAQP would have allowed reduced VRs without additional contaminant-reduction strategies. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.
INDOOR AIR QUALITY MODEL VERSION 1.0 DOCUMENTATION
The report presents a multiroom model for estimating the impact of various sources on indoor air quality (IAQ). The model is written for use on IBM-PC and compatible microcomputers. It is easy to use with a menu-driven user interface. Data are entered using a fill-in-a-form inter...
HVAC SYSTEMS AS A TOOL IN CONTROLLING INDOOR AIR QUALITY: A LITERATURE REVIEW
The report gives results of a review of literature on the use of heating, ventilating, and air-conditioning (HVAC) systems to control indoor air quality (IAQ). Although significant progress has been made in reducing the energy consumption of HVAC systems, their effect on indoor a...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dutton, Spencer M.; Chan, Wanyu R.; Mendell, Mark J.
California's building efficiency standards (Title 24) mandate minimum prescribed ventilation rates (VRs) for commercial buildings. Title 24 standards currently include a prescriptive procedure similar to ASHRAE’s prescriptive “ventilation rate procedure”, but does not include an alternative procedure, akin to ASHRAE’s non-prescriptive “indoor air quality procedure” (IAQP). The IAQP determines minimum VRs based on objectively and subjectively evaluated indoor air quality (IAQ). The first primary goal of this study was to determine, in a set of California retail stores, the adequacy of Title 24 VRs and observed current measured VRs in providing the level of IAQ specified through an IAQP process,more » The second primary goal was to evaluate whether several VRs implemented experimentally in a big box store would achieve adequate IAQ, assessed objectively and subjectively. For the first goal, a list of contaminants of concern (CoCs) and reference exposure levels (RELs) were selected for evaluating IAQ. Ventilation rates and indoor and outdoor CoC concentrations were measured in 13 stores, including one “big box” store. Mass balance models were employed to calculate indoor contaminant source strengths for CoCs in each store. Using these source strengths and typical outdoor air contaminant concentrations, mass balance models were again used to calculate for each store the “IAQP” VR that would maintain indoor CoC concentrations below selected RELs. These IAQP VRs were compared to the observed VRs and to the Title 24- prescribed VRs. For the second goal, a VR intervention study was performed in the big box store to determine how objectively assessed indoor contaminant levels and subjectively assessed IAQ varied with VR. The three intervention study VRs included an approximation of the store’s current VR [0.24 air changes per hour (ACH)], the Title 24-prescribed VR [0.69 ACH], and the calculated IAQPbased VR [1.51 ACH]). Calculations of IAQP-based VRs showed that for the big box store and 11 of the 12 other stores, neither current measured VRs nor the Title 24-prescribed VRs would be sufficient to maintain indoor concentrations of all CoCs below RELs. In the intervention study, with the IAQP-based VR applied in the big box store, all CoCs were controlled below RELs (within margins of error). Also, at all three VRs in this store, the percentage of subjects reporting acceptable air quality exceeded an 80% criterion of acceptability. The IAQP allows consideration of outdoor air ventilation as just one of several possible tools for achieving adequate IAQ. In two of the 13 surveyed buildings, applying the IAQP to allow lower VRs could have saved energy whilst still maintaining acceptable indoor air quality. In the remaining 11 buildings, saving energy through lower VRs would require combination with other strategies, either reducing indoor sources of CoCs such as formaldehyde, or use of gas phase air cleaning technologies. Based on the findings from applying the IAQP calculations to retail stores and the IAQP-based intervention study, recommendations are made regarding the potential introduction of a comparable procedure in Title 24.« less
A statistical model for characterizing common air pollutants in air-conditioned offices
NASA Astrophysics Data System (ADS)
Wong, L. T.; Mui, K. W.; Hui, P. S.
Maintaining acceptable indoor air quality (IAQ) for a healthy environment is of primary concern, policymakers have developed different strategies to address the performance of it based on proper assessment methodologies and monitoring plans. It could be cost prohibitive to sample all toxic pollutants in a building. In search of a more manageable number of parameters for cost-effective IAQ assessment, this study investigated the probable correlations among the 12 indoor environmental parameters listed in the IAQ certification scheme of the Hong Kong Environment Protection Department (HKEPD) in 422 Hong Kong offices. These 12 parameters consists of nine indoor air pollutants: carbon dioxide (CO 2), carbon monoxide (CO), respirable suspended particulates (RSP), nitrogen dioxide (NO 2), ozone (O 3), formaldehyde (HCHO), total volatile organic compounds (TVOC), radon (Rn), airborne bacteria count (ABC); and three thermal comfort parameters: temperature ( T), relative humidity (RH) and air velocity ( V). The relative importance of the correlations derived, from largest to smallest loadings, was ABC, Rn, CO, RH, RSP, CO 2, TVOC, O 3, T, V, NO 2 and HCHO. Together with the mathematical expressions derived, an alternative sampling protocol for IAQ assessment with the three 'most representative and independent' parameters namely RSP, CO 2 and TVOC measured in an office environment was proposed. The model validity was verified with on site measurements from 43 other offices in Hong Kong. The measured CO 2, RSP and TVOC concentrations were used to predict the probable levels of the other nine parameters and good agreement was found between the predictions and measurements. This simplified protocol provides an easy tool for performing IAQ monitoring in workplaces and will be useful for determining appropriate mitigation measures to finally honor the certification scheme in a cost-effective way.
Modeling the resiliency of energy-efficient retrofits in low-income multifamily housing.
Underhill, L J; Fabian, M P; Vermeer, K; Sandel, M; Adamkiewicz, G; Leibler, J H; Levy, J I
2018-05-01
Residential energy efficiency and ventilation retrofits (eg, building weatherization, local exhaust ventilation, HVAC filtration) can influence indoor air quality (IAQ) and occupant health, but these measures' impact varies by occupant activity. In this study, we used the multizone airflow and IAQ analysis program CONTAM to simulate the impacts of energy retrofits on indoor concentrations of PM 2.5 and NO 2 in a low-income multifamily housing complex in Boston, Massachusetts (USA). We evaluated the differential impact of residential activities, such as low- and high-emission cooking, cigarette smoking, and window opening, on IAQ across two seasons. We found that a comprehensive package of energy and ventilation retrofits was resilient to a range of occupant activities, while less holistic approaches without ventilation improvements led to increases in indoor PM 2.5 or NO 2 for some populations. In general, homes with simulated concentration increases included those with heavy cooking and no local exhaust ventilation, and smoking homes without HVAC filtration. Our analytical framework can be used to identify energy-efficient home interventions with indoor retrofit resiliency (ie, those that provide IAQ benefits regardless of occupant activity), as well as less resilient retrofits that can be coupled with behavioral interventions (eg, smoking cessation) to provide cost-effective, widespread benefits. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Healthy Efficient New Gas Homes (HENGH) Pilot Test Results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chan, Wanyu R.; Maddalena, Randy L; Stratton, Chris
The Healthy Efficient New Gas Homes (HENGH) is a field study that will collect data on ventilation systems and indoor air quality (IAQ) in new California homes that were built to 2008 Title 24 standards. A pilot test was performed to help inform the most time and cost effective approaches to measuring IAQ in the 100 test homes that will be recruited for this study. Two occupied, single-family detached homes built to 2008 Title 24 participated in the pilot test. One of the test homes uses exhaust-only ventilation provided by a continuous exhaust fan in the laundry room. The othermore » home uses supply air for ventilation. Measurements of IAQ were collected for two weeks. Time-resolved concentrations of particulate matter (PM), nitrogen dioxide (NO2), carbon dioxide (CO2), carbon monoxide (CO), and formaldehyde were measured. Measurements of IAQ also included time-integrated concentrations of volatile organic compounds (VOCs), volatile aldehydes, and NO2. Three perfluorocarbon tracers (PFTs) were used to estimate the dilution rate of an indoor emitted air contaminant in the two pilot test homes. Diagnostic tests were performed to measure envelope air leakage, duct leakage, and airflow of range hood, exhaust fans, and clothes dryer vent when accessible. Occupant activities, such as cooking, use of range hood and exhaust fans, were monitored using various data loggers. This document describes results of the pilot test.« less
Introduction to Indoor Air Quality
... as conditions caused by outdoor impacts (such as climate change). Many reports and studies indicate that the following ... Air Duct Cleaning Asthma Health, Energy Efficiency and Climate Change Flood Cleanup IAQ at Home Indoor airPLUS Mold ...
ERIC Educational Resources Information Center
Schneider, Christian M.
1990-01-01
The heating, ventilating, and air conditioning (HVAC) systems in older buildings often do not adequately handle air-borne contaminants. Outlines a three-stage Indoor Air Quality (IAQ) assessment and describes a case in point at a Pittsburgh, Pennsylvania, school. (MLF)
Coombs, Kanistha C; Chew, Ginger L; Schaffer, Christopher; Ryan, Patrick H; Brokamp, Cole; Grinshpun, Sergey A; Adamkiewicz, Gary; Chillrud, Steve; Hedman, Curtis; Colton, Meryl; Ross, Jamie; Reponen, Tiina
2016-06-01
Green eco-friendly housing includes approaches to reduce indoor air pollutant sources and to increase energy efficiency. Although sealing/tightening buildings can save energy and reduce the penetration of outdoor pollutants, an adverse outcome can be increased buildup of pollutants with indoor sources. The objective of this study was to determine the differences in the indoor air quality (IAQ) between green and non-green homes in low-income housing complexes. In one housing complex, apartments were renovated using green principles (n=28). Home visits were conducted immediately after the renovation, and subsequently at 6 months and at 12 months following the renovation. Of these homes, eight homes had pre-renovation home visits; this allowed pre- and post-renovation comparisons within the same homes. Parallel visits were conducted in non-green (control) apartments (n=14) in a nearby low-income housing complex. The IAQ assessments included PM2.5, black carbon, ultrafine particles, sulfur, total volatile organic compounds (VOCs), formaldehyde, and air exchange rate. Data were analyzed using linear mixed-effects models. None of the indoor pollutant concentrations were significantly different between green and non-green homes. However, we found differences when comparing the concentrations before and after renovation. Measured immediately after renovation, indoor black carbon concentrations were significantly lower averaging 682 ng/m(3) in post-renovation vs. 2364 ng/m(3) in pre-renovation home visits (p=0.01). In contrast, formaldehyde concentrations were significantly higher in post-renovated (0.03 ppm) than in pre-renovated homes (0.01 ppm) (p=0.004). Questionnaire data showed that opening of windows occurred less frequently in homes immediately post-renovation compared to pre-renovation; this factor likely affected the levels of indoor black carbon (from outdoor sources) and formaldehyde (from indoor sources) more than the renovation status itself. To reduce IAQ problems and potentially improve health, careful selection of indoor building materials and ensuring sufficient ventilation are important for green building designs. Copyright © 2016 Elsevier B.V. All rights reserved.
Environmentally Related Health Hazards in the Schools.
ERIC Educational Resources Information Center
Andrews, James B.; Neuroth, Richard
The quality of air inside the schoolhouses of America may have a profound effect on students' ability to concentrate on their lessons. The environmental hazards that influence the quality of the indoor air (IAQ) of our schools have not been well understood. Research evidence suggests that school age children and youth (especially those under the…
Indoor Air Quality Management Program.
ERIC Educational Resources Information Center
Anne Arundel County Public Schools, Annapolis, MD.
In an effort to provide Indoor Air Quality (IAQ) management guidance, Anne Arundel County Public Schools was selected by the Maryland State Department of Education to develop a program that could be used by other school systems. A major goal was to produce a handbook that was "user friendly." Hence, its contents are a mix of history,…
IAQ Tools for Schools: Managing Asthma in the School Environment.
ERIC Educational Resources Information Center
Environmental Protection Agency, Washington, DC. Office of Radiation and Indoor Air.
This manual provides tips on improving indoor air quality within the school environment by removing the elements that trigger asthma attacks in children, and presents a list of organizations where asthma resource information can be obtained. Air quality management tips cover removing of animal and cockroach allergens, cleaning up mold and…
Maintaining Acceptable Indoor Air Quality during the Renovation of a School. Technical Bulletin.
ERIC Educational Resources Information Center
Jacobs, Bruce W.
Information that school facility personnel can use concerning the potential impacts of renovation projects on indoor air quality (IAQ), along with details of some effective control strategies, are presented. Various kinds of contaminants may be generated by renovations, including volatile and semivolatile organic compounds, dusts and fibers (e.g.,…
Building Air Quality: A Guide for Building Owners and Facility Managers.
ERIC Educational Resources Information Center
Agle, Elizabeth; Galbraith, Susan
The past two decades have witnessed increased concerns over the health and comfort of indoor air quality (IAQ), but little indoor air-related information has been targeted at building owners and facility managers of public and commercial buildings. This manual, specifically created for such a population, provides guidance on preventing,…
IAQ Tools for Schools Awards, 2000-2002.
ERIC Educational Resources Information Center
Environmental Protection Agency, Washington, DC.
This document provides descriptions of the 2000, 2001, and 2002 winners of the Environmental Protection Agency's Indoor Air Quality Tools for Schools Excellence Awards. The winners are considered to be national leaders in improving indoor air quality in schools. Also included are case studies for selected 2000 winners and a press release for the…
More information on testing for maximum indoor pollutant concentrations for acceptance of the facility, as well as requirements for Independent Materials Testing of specific materials anticipated to have major impact on indoor air quality.
Overview of the Building Assessment Survey and Evaluation Study
The Building Assessment Survey and Evaluation (BASE) study was conducted over a five-year period from 1994-1998, to characterize determinants of indoor air quality (IAQ) and occupant perceptions in representative public and commercial office buildings.
Kennedy NASA Procedural Requirements 1840.19, Indoor Air Quality Section
This Section establishes the IAQ management program at Kennedy Space Center. The support services described in this section are available to all Civil Service organizations and NASA contractor organizations as defined in their respective contracts.
Monitoring biodiversity in libraries: a pilot study and perspectives for indoor air quality.
Valeriani, F; Cianfanelli, C; Gianfranceschi, G; Santucci, S; Romano Spica, V; Mucci, N
2017-09-01
Indoor Air Quality (IAQ) in libraries is influenced by the presence of specific factors which can impact on both paper storage as well as people health. Microclimatic conditions induce and support a biodiversity pattern involving environmental and anthropic microorganisms. We used a multidisciplinary monitoring model to characterize microflora biodiversity by Next Generation Sequencing (NGS). Biodiversity indexes were adapted to evaluate anthropic vs environmental pollution by combining Shannon mean index (H), species representativeness (E H ), human/environmental pollution ratio (SA) to better characterize the NGS output and acquire synthetic information on Indoor Air Microbial Biodiversity (IAMB). Results indicate a frequently low microbial load (IGCM/m 3 < 1000) characterized by different species (n = 102), including several cellulose metabolizing bacteria. Workers and visitors appeared a relevant source of microbial contamination. Air biodiversity assayed by NGS seems a promising marker for studying IAQ.
Employing ASHRAE Standard 62-1989 in urban building environments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meckler, M.
1991-01-01
Indoor air quality (IAQ) is a result of a complex relationship between the contamination sources in a building, the ventilation rate, and the dilution of the indoor air contaminant concentrations with outdoor air. This complex relationship is further complicated by outdoor sources used for dilution air and pollution sinks in a building which may modify or remove contaminants. This paper reports that the factors influencing IAQ in a building are: emissions from indoor contamination sources, dilution rate of outdoor ventilation air, quality of the outdoor dilution air, and systems and materials in a building that change the concentrations of contaminants.more » Emissions from contaminant sources in a building are the primary determinant of IAQ. They include building materials, consumer products, cleaners, furnishings, combustion appliances and processes, biological growth from standing water and damp surfaces and building occupants. These factors combined with the emissions from indoor air contamination sources such as synthetic building materials, modern office equipment, and cleaning and biological agents are believed to increase the levels of indoor air contamination. The physiological reactions to these contaminants, coupled with the psychosocial stresses of the modern office environment, and the wide range of human susceptibility to indoor air contaminants led to the classification of acute building sicknesses: sick building syndrome (SBS), building-related illness (BRI), and multiple chemical sensitivity (MCS).« less
Low temperature air with high IAQ for dry climates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scofield, C.M.; Des Champs, N.H.
1995-01-01
This article describes how low temperature supply air and air-to-air heat exchangers can furnish 100% outdoor air with reduced peak energy demands. The use of low temperature supply air systems in arid climates greatly simplifies the air-conditioning design. Risks associated with moisture migration and sweating of duct and terminal equipment are reduced. Insulation and vapor barrier design requirements are not nearly as critical as they are in the humid, ambient conditions that exist in the eastern United States. The introduction of outdoor air to meet ASHRAE Standard 62-1989 becomes far less taxing on the mechanical cooling equipment because of themore » lower enthalpy levels of the dry western climate. Energy costs to assure indoor air quality (IAQ) are lower than for more tropical climates. In arid regions, maintaining acceptable indoor relative humidity (RH) levels becomes a major IAQ concern. For the western United States, coupling an air-to-air heat exchanger to direct (adiabatic) evaporative coolers can greatly reduce low temperature supply air refrigeration energy requirements and winter humidification costs while ensuring proper ventilation.« less
Antimicrobial Treatments of Indoor Mold and Bacteria
Biological contaminants especially mold in buildings are known to act as sources of indoor air pollution, discomfort, asthma and pulmonary disease to building occupants. Sick buildings are evidence of extremely problematic indoor air quality (IAQ), often resulting from unacceptab...
Indoor Air Quality & Preventive Maintenance Value Proposition Worksheet
Part of our outreach and education to our webinar registrants is providing them a copy of the Value Proposition Worksheet which accompanies the webinar topic. For this particular webinar the topic is focused on IAQ and Preventive Maintenance.
EVALUATING SOURCES OF INDOOR AIR POLLUTION
The article discusses a three-phase approach, employing environmental chambers, indoor air quality (IAQ) models, and test house experiments, that is effective in linking sources of indoor pollutants to measured concentrations. mission factors developed in test chambers can be use...
PARAMS is a Windows-based computer program that implements 30 methods for estimating the parameters in indoor emissions source models, which are an essential component of indoor air quality (IAQ) and exposure models. These methods fall into eight categories: (1) the properties o...
Webinar: Healthy Schools, Healthy Students: Taking Action to Improve IAQ in Your School District
A page to register to view the first webinar in the IAQ Knowledge-to-Action Professional Training Webinar Series: Healthy Schools, Healthy Students: Taking Action to Improve IAQ in Your School District
Du, Liuliu; Batterman, Stuart; Godwin, Christopher; Chin, Jo-Yu; Parker, Edith; Breen, Michael; Brakefield, Wilma; Robins, Thomas; Lewis, Toby
2012-12-12
Air change rates (ACRs) and interzonal flows are key determinants of indoor air quality (IAQ) and building energy use. This paper characterizes ACRs and interzonal flows in 126 houses, and evaluates effects of these parameters on IAQ. ACRs measured using weeklong tracer measurements in several seasons averaged 0.73 ± 0.76 h(-1) (median = 0.57 h(-1), n = 263) in the general living area, and much higher, 1.66 ± 1.50 h(-1) (median = 1.23 h(-1), n = 253) in bedrooms. Living area ACRs were highest in winter and lowest in spring; bedroom ACRs were highest in summer and lowest in spring. Bedrooms received an average of 55 ± 18% of air from elsewhere in the house; the living area received only 26 ± 20% from the bedroom. Interzonal flows did not depend on season, indoor smoking or the presence of air conditioners. A two-zone IAQ model calibrated for the field study showed large differences in pollutant levels between the living area and bedroom, and the key parameters affecting IAQ were emission rates, emission source locations, air filter use, ACRs, interzonal flows, outdoor concentrations, and PM penetration factors. The single-zone models that are commonly used for residences have substantial limitations and may inadequately represent pollutant concentrations and exposures in bedrooms and potentially other environments other where people spend a substantial fraction of time.
Du, Liuliu; Batterman, Stuart; Godwin, Christopher; Chin, Jo-Yu; Parker, Edith; Breen, Michael; Brakefield, Wilma; Robins, Thomas; Lewis, Toby
2012-01-01
Air change rates (ACRs) and interzonal flows are key determinants of indoor air quality (IAQ) and building energy use. This paper characterizes ACRs and interzonal flows in 126 houses, and evaluates effects of these parameters on IAQ. ACRs measured using weeklong tracer measurements in several seasons averaged 0.73 ± 0.76 h−1 (median = 0.57 h−1, n = 263) in the general living area, and much higher, 1.66 ± 1.50 h−1 (median = 1.23 h−1, n = 253) in bedrooms. Living area ACRs were highest in winter and lowest in spring; bedroom ACRs were highest in summer and lowest in spring. Bedrooms received an average of 55 ± 18% of air from elsewhere in the house; the living area received only 26 ± 20% from the bedroom. Interzonal flows did not depend on season, indoor smoking or the presence of air conditioners. A two-zone IAQ model calibrated for the field study showed large differences in pollutant levels between the living area and bedroom, and the key parameters affecting IAQ were emission rates, emission source locations, air filter use, ACRs, interzonal flows, outdoor concentrations, and PM penetration factors. The single-zone models that are commonly used for residences have substantial limitations and may inadequately represent pollutant concentrations and exposures in bedrooms and potentially other environments other where people spend a substantial fraction of time. PMID:23235286
Representativeness of shorter measurement sessions in long-term indoor air monitoring.
Maciejewska, M; Szczurek, A
2015-02-01
Indoor air quality (IAQ) considerably influences health, comfort and the overall performance of people who spend most of their lives in confined spaces. For this reason, there is a strong need to develop methods for IAQ assessment. The fundamental issue in the quantitative determination of IAQ is the duration of measurements. Its inadequate choice may result in providing incorrect information and this potentially leads to wrong conclusions. The most complete information may be acquired through long-term monitoring. However it is typically perceived as impractical due to time and cost load. The aim of this study was to determine whether long-term monitoring can be adequately represented by a shorter measurement session. There were considered three measurable quantities: temperature, relative humidity and carbon dioxide concentration. They are commonly recognized as indicatives for IAQ and may be readily monitored. Scaled Kullback-Leibler divergence, also called relative entropy, was applied as a measure of data representativeness. We considered long-term monitoring in a range from 1 to 9 months. Based on our work, the representative data on CO2 concentration may be acquired while performing measurements during 20% of time dedicated to long-term monitoring. In the case of temperature and relative humidity the respective time demand was 50% of long-term monitoring. From our results, in indoor air monitoring strategies, there could be considered shorter measurement sessions, while still collecting data which are representative for long-term monitoring.
A System Based on the Internet of Things for Real-Time Particle Monitoring in Buildings
Roque Ferreira, Cristina; Pitarma, Rui
2018-01-01
Occupational health can be strongly influenced by the indoor environment as people spend 90% of their time indoors. Although indoor air quality (IAQ) is not typically monitored, IAQ parameters could be in many instances very different from those defined as healthy values. Particulate matter (PM), a complex mixture of solid and liquid particles of organic and inorganic substances suspended in the air, is considered the pollutant that affects more people. The most health-damaging particles are the ≤PM10 (diameter of 10 microns or less), which can penetrate and lodge deep inside the lungs, contributing to the risk of developing cardiovascular and respiratory diseases, as well as of lung cancer. This paper presents an Internet of Things (IoT) system for real-time PM monitoring named iDust. This system is based on a WEMOS D1 mini microcontroller and a PMS5003 PM sensor that incorporates scattering principle to measure the value of particles suspended in the air (PM10, PM2.5, and PM1.0). Through a Web dashboard for data visualization and remote notifications, the building manager can plan interventions for enhanced IAQ and ambient assisted living (AAL). Compared to other solutions the iDust is based on open-source technologies, providing a total Wi-Fi system, with several advantages such as its modularity, scalability, low cost, and easy installation. The results obtained are very promising, representing a meaningful tool on the contribution to IAQ and occupational health. PMID:29690534
A System Based on the Internet of Things for Real-Time Particle Monitoring in Buildings.
Marques, Gonçalo; Roque Ferreira, Cristina; Pitarma, Rui
2018-04-21
Occupational health can be strongly influenced by the indoor environment as people spend 90% of their time indoors. Although indoor air quality (IAQ) is not typically monitored, IAQ parameters could be in many instances very different from those defined as healthy values. Particulate matter (PM), a complex mixture of solid and liquid particles of organic and inorganic substances suspended in the air, is considered the pollutant that affects more people. The most health-damaging particles are the ≤PM 10 (diameter of 10 microns or less), which can penetrate and lodge deep inside the lungs, contributing to the risk of developing cardiovascular and respiratory diseases, as well as of lung cancer. This paper presents an Internet of Things (IoT) system for real-time PM monitoring named iDust. This system is based on a WEMOS D1 mini microcontroller and a PMS5003 PM sensor that incorporates scattering principle to measure the value of particles suspended in the air (PM 10 , PM 2.5 , and PM 1.0 ). Through a Web dashboard for data visualization and remote notifications, the building manager can plan interventions for enhanced IAQ and ambient assisted living (AAL). Compared to other solutions the iDust is based on open-source technologies, providing a total Wi-Fi system, with several advantages such as its modularity, scalability, low cost, and easy installation. The results obtained are very promising, representing a meaningful tool on the contribution to IAQ and occupational health.
ERIC Educational Resources Information Center
Mak, Lily
2012-01-01
When it comes to excelling in the classroom, it turns out the air students are breathing is just as important as the lessons they are learning. Studies show poor indoor air quality (IAQ) can lessen the comfort of students as well as staff--affecting concentration, attendance and student performance. It can even lead to lower IQs. What's more, poor…
VENTILATION TECHNOLOGY SYSTEMS ANALYSIS
The report gives results of a project to develop a systems analysis of ventilation technology and provide a state-of-the-art assessment of ventilation and indoor air quality (IAQ) research needs. (NOTE: Ventilation technology is defined as the hardware necessary to bring outdoor ...
A page to register to view the first webinar in the IAQ Knowledge-to-Action Professional Training Webinar Series: Know the Drill for Healthy IAQ: Training School Staff and Occupants to Reduce Indoor Asthma Triggers
Salamone, Francesco; Belussi, Lorenzo; Danza, Ludovico; Galanos, Theodore; Ghellere, Matteo; Meroni, Italo
2017-05-04
The article describes the results of the project "open source smart lamp" aimed at designing and developing a smart object able to manage and control the indoor environmental quality (IEQ) of the built environment. A first version of this smart object, built following a do-it-yourself (DIY) approach using a microcontroller, an integrated temperature and relative humidity sensor, and techniques of additive manufacturing, allows the adjustment of the indoor thermal comfort quality (ICQ), by interacting directly with the air conditioner. As is well known, the IEQ is a holistic concept including indoor air quality (IAQ), indoor lighting quality (ILQ) and acoustic comfort, besides thermal comfort. The upgrade of the smart lamp bridges the gap of the first version of the device providing the possibility of interaction with the air exchange unit and lighting system in order to get an overview of the potential of a nearable device in the management of the IEQ. The upgraded version was tested in a real office equipped with mechanical ventilation and an air conditioning system. This office was occupied by four workers. The experiment is compared with a baseline scenario and the results show how the application of the nearable device effectively optimizes both IAQ and ILQ.
Salamone, Francesco; Belussi, Lorenzo; Danza, Ludovico; Galanos, Theodore; Ghellere, Matteo; Meroni, Italo
2017-01-01
The article describes the results of the project “open source smart lamp” aimed at designing and developing a smart object able to manage and control the indoor environmental quality (IEQ) of the built environment. A first version of this smart object, built following a do-it-yourself (DIY) approach using a microcontroller, an integrated temperature and relative humidity sensor, and techniques of additive manufacturing, allows the adjustment of the indoor thermal comfort quality (ICQ), by interacting directly with the air conditioner. As is well known, the IEQ is a holistic concept including indoor air quality (IAQ), indoor lighting quality (ILQ) and acoustic comfort, besides thermal comfort. The upgrade of the smart lamp bridges the gap of the first version of the device providing the possibility of interaction with the air exchange unit and lighting system in order to get an overview of the potential of a nearable device in the management of the IEQ. The upgraded version was tested in a real office equipped with mechanical ventilation and an air conditioning system. This office was occupied by four workers. The experiment is compared with a baseline scenario and the results show how the application of the nearable device effectively optimizes both IAQ and ILQ. PMID:28471398
Smart ventilation energy and indoor air quality performance in residential buildings: A review
Guyot, Gaelle; Sherman, Max H.; Walker, Iain S.
2017-12-30
To better address energy and indoor air quality issues, ventilation needs to become smarter. A key smart ventilation concept is to use controls to ventilate more at times it provides either an energy or indoor air quality (IAQ) advantage (or both) and less when it provides a disadvantage. A favorable context exists in many countries to include some of the existing smart ventilation strategies in codes and standards. As a result, demand-controlled ventilation (DCV) systems are widely and easily available on the market, with more than 20 DCV systems approved and available in countries such as Belgium, France and themore » Netherlands. This paper provides a literature review on smart ventilation used in residential buildings, based on energy and indoor air quality performance. This meta-analysis includes 38 studies of various smart ventilation systems with control based on CO 2, humidity, combined CO 2 and total volatile organic compounds (TVOC), occupancy, or outdoor temperature. In conclusion, these studies show that ventilation energy savings up to 60% can be obtained without compromising IAQ, even sometimes improving it. However, the meta-analysis included some less than favorable results, with 26% energy overconsumption in some cases.« less
Smart ventilation energy and indoor air quality performance in residential buildings: A review
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guyot, Gaelle; Sherman, Max H.; Walker, Iain S.
To better address energy and indoor air quality issues, ventilation needs to become smarter. A key smart ventilation concept is to use controls to ventilate more at times it provides either an energy or indoor air quality (IAQ) advantage (or both) and less when it provides a disadvantage. A favorable context exists in many countries to include some of the existing smart ventilation strategies in codes and standards. As a result, demand-controlled ventilation (DCV) systems are widely and easily available on the market, with more than 20 DCV systems approved and available in countries such as Belgium, France and themore » Netherlands. This paper provides a literature review on smart ventilation used in residential buildings, based on energy and indoor air quality performance. This meta-analysis includes 38 studies of various smart ventilation systems with control based on CO 2, humidity, combined CO 2 and total volatile organic compounds (TVOC), occupancy, or outdoor temperature. In conclusion, these studies show that ventilation energy savings up to 60% can be obtained without compromising IAQ, even sometimes improving it. However, the meta-analysis included some less than favorable results, with 26% energy overconsumption in some cases.« less
Indoor air quality at restaurants with different styles of cooking in metropolitan Hong Kong.
Lee, S C; Li, W M; Chan, L Y
2001-11-12
Indoor air quality (IAQ) of a restaurant has increasingly received a lot of public concerns in Hong Kong. Unfortunately, there is limited data about the IAQ of Hong Kong restaurants. In order to characterize the current IAQ of local restaurants, four restaurants in metropolitan Hong Kong including a Korean barbecue style restaurant, a Chinese hot pot restaurant, a Chinese dim sum restaurant and a Western canteen were selected for this study. The results of this study showed that the mean concentrations of CO2 at restaurants with gas stoves for food cooking in dining areas exceeded the range from 40 to 60% indoor CO2 concentrations at restaurants without gas stoves in dining areas. The average levels of PM10 and PM2.5 at the Korean barbecue style restaurant were as high as 1442 and 1167 microg/m3, respectively. At the Korean barbecue and Chinese hot pot restaurants, the levels of PM2.5 accounted for 80-93% of their respective PM10 concentrations. The 1-h average levels of CO observed at Korean barbecue style and hot pot restaurants were 15,100 and 8000 microg/m3, respectively. Relatively high concentrations of CO2, CO, PM10, PM2.5 benzene, toluene, methylene chloride and chloroform were measured in the dining areas of the Korean barbecue style and the Chinese hot pot restaurants. The operations of pan-frying food and boiling food with soup in a hot pot could generate considerable quantities of air pollutants.
Quality assurance strategies for investigating IAQ problems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Collett, C.W.; Ross, J.A.; Sterling, E.M.
Thousands of buildings have now been investigated throughout North America and western Europe. The evaluative strategies and protocols used by various investigators have been described in the scientific and protocols used by various investigators have been described in the scientific and technical literature, including those used by government agencies, private consultants, researchers, and physicians. Review of these strategies shows a consistency and commonly in approach, despite differences in terminology and organization. Most of the published protocols recognize the need to employ a multidisciplinary approach to the evaluation of indoor environmental problems, an approach that views buildings as complex, dynamic systems.more » The multidisciplinary approaches advocated by investigators gather information about the physical building (architectural), the mechanical systems that control indoor environmental conditions (engineering), the type and extent of occupant health and comfort concerns (medical), the objective quality of the air (industrial hygiene) and the occupants subjective perceptions of conditions in their work environment (social science). These components have generally been organized into a series of steps or phases, with each phase extending the information gathered from the preceding phase until a point when the causes of problems may be identified.« less
A coupled airflow and source/sink model for simulating indoor VOC exposures.
Yang, X; Chen, Q
2001-12-01
In this paper, a numerical model is presented to study the indoor air quality (IAQ) in a room with different emission sources, sinks, and ventilation methods. A computer program, ACCESS-IAQ, is developed to simulate the airflow pattern, the time history of the contaminant concentrations in the occupied zone, and the inhalation exposures. The program developed may be useful for IAQ professional to design healthy and comfortable indoor environments. A numerical study has been carried out to predict the effectiveness of a displacement ventilation and a mixing ventilation on volatile organic compound (VOC) removal in a model office. Results from the numerical predictions show that when a "wet" emission source (a freshly painted wood stain) is distributed uniformly across the floor area with sinks (gypsum board) from the four vertical walls, displacement ventilation has consistently lower exposure at the breathing level of the occupant in the room. Such an effect is mainly due to the higher ventilation efficiency of displacement ventilation compared to the mixing ventilation. The simulation results also show that the walls adsorb significant amounts of VOCs during the first hour and act as secondary sources thereafter.
Children exposure to atmospheric particles in indoor of Lisbon primary schools
NASA Astrophysics Data System (ADS)
Almeida, Susana Marta; Canha, Nuno; Silva, Ana; Freitas, Maria do Carmo; Pegas, Priscilla; Alves, Célia; Evtyugina, Margarita; Pio, Casimiro Adrião
2011-12-01
Evidence continues to emerge showing that poor Indoor Air Quality (IAQ) can cause illness requiring absence from schools, and can cause acute health symptoms that decrease students' performance. Since children spend on average 7-11 h per weekday at school, the IAQ in classrooms is expected to play a key role in the assessment of the effects of their personal exposure to air pollution. Within this context the present study was conducted in order to fulfill three primary objectives 1) to measure the levels and the element composition of PM 2.5 and PM 2.5-10, in three primary schools placed in Lisbon, in order to assess the children exposure to these pollutants; 2) to study the relationship between indoor and outdoor atmospheric particles concentrations and 3) to investigate the sources of high aerosols concentrations in classrooms. In the studied classrooms, the concentrations of coarse particles significantly exceeded the ambient levels. Element concentrations suggested that the physical activity of students highly contributed to the re-suspension of sedimented particles. The high levels of CO 2 indicated that in these schools the ventilation was inadequate. This fact contributed to the establishment of poor IAQ.
Assessment of ventilation and indoor air pollutants in nursery and elementary schools in France.
Canha, N; Mandin, C; Ramalho, O; Wyart, G; Ribéron, J; Dassonville, C; Hänninen, O; Almeida, S M; Derbez, M
2016-06-01
The aim of this study was to characterize the relationship between Indoor Air Quality (IAQ) and ventilation in French classrooms. Various parameters were measured over one school week, including volatile organic compounds, aldehydes, particulate matter (PM2.5 mass concentration and number concentration), carbon dioxide (CO2 ), air temperature, and relative humidity in 51 classrooms at 17 schools. The ventilation was characterized by several indicators, such as the air exchange rate, ventilation rate (VR), and air stuffiness index (ICONE), that are linked to indoor CO2 concentration. The influences of the season (heating or non-heating), type of school (nursery or elementary), and ventilation on the IAQ were studied. Based on the minimum value of 4.2 l/s per person required by the French legislation for mechanically ventilated classrooms, 91% of the classrooms had insufficient ventilation. The VR was significantly higher in mechanically ventilated classrooms compared with naturally ventilated rooms. The correlations between IAQ and ventilation vary according to the location of the primary source of each pollutant (outdoor vs. indoor), and for an indoor source, whether it is associated with occupant activity or continuous emission. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
MODELING OF ALKANE EMISSIONS FROM A WOOD STAIN
The article discusses full-scale residential house tests to evaluate the effects of organic emissions from a wood finishing product--wood stain--on indoor air quality (IAQ). The test house concentrations of three alkane species, nonane, decane, and undecane, were measured as a fu...
AN ANALYTICAL METHOD FOR THE MEASUREMENT OF NONVIABLE BIOAEROSOLS
Exposures from indoor environments are a major issue for evaluating total long-term personal exposure to the fine fraction (<2.5 micrometers in aerodynamic diameter) of particulate matter (PM). It is widely accepted in the indoor air quality (IAQ) research community that bioconta...
The paper discusses methods for characterizing chemical emissions from material sources, including laboratory, dynamic chamber, and full-scale studies. Indoor sources and their interaction with sinks play a major role in determining indoor air quality (IAQ). Techniques for evalua...
REVIEW OF INDOOR EMISSION SOURCE MODELS--PART 1. OVERVIEW
Indoor emission source models are mainly used as a component in indoor air quality (IAQ) and exposure modeling. They are also widely used to interpret the experimental data obtained from environmental chambers and buildings. This paper compiles 46 indoor emission source models fo...
Monitoring Indoor Air Quality for Enhanced Occupational Health.
Pitarma, Rui; Marques, Gonçalo; Ferreira, Bárbara Roque
2017-02-01
Indoor environments are characterized by several pollutant sources. Because people spend more than 90% of their time in indoor environments, several studies have pointed out the impact of indoor air quality on the etiopathogenesis of a wide number of non-specific symptoms which characterizes the "Sick Building Syndrome", involving the skin, the upper and lower respiratory tract, the eyes and the nervous system, as well as many building related diseases. Thus, indoor air quality (IAQ) is recognized as an important factor to be controlled for the occupants' health and comfort. The majority of the monitoring systems presently available is very expensive and only allow to collect random samples. This work describes the system (iAQ), a low-cost indoor air quality monitoring wireless sensor network system, developed using Arduino, XBee modules and micro sensors, for storage and availability of monitoring data on a web portal in real time. Five micro sensors of environmental parameters (air temperature, humidity, carbon monoxide, carbon dioxide and luminosity) were used. Other sensors can be added for monitoring specific pollutants. The results reveal that the system can provide an effective indoor air quality assessment to prevent exposure risk. In fact, the indoor air quality may be extremely different compared to what is expected for a quality living environment. Systems like this would have benefit as public health interventions to reduce the burden of symptoms and diseases related to "sick buildings".
Valeriani, F.; Cianfanelli, C.; Gianfranceschi, G.; Santucci, S.; Romano Spica, V.
2017-01-01
Summary Indoor Air Quality (IAQ) in libraries is influenced by the presence of specific factors which can impact on both paper storage as well as people health. Microclimatic conditions induce and support a biodiversity pattern involving environmental and anthropic microorganisms. We used a multidisciplinary monitoring model to characterize microflora biodiversity by Next Generation Sequencing (NGS). Biodiversity indexes were adapted to evaluate anthropic vs environmental pollution by combining Shannon mean index (H), species representativeness (EH), human/environmental pollution ratio (SA) to better characterize the NGS output and acquire synthetic information on Indoor Air Microbial Biodiversity (IAMB). Results indicate a frequently low microbial load (IGCM/m3 < 1000) characterized by different species (n = 102), including several cellulose metabolizing bacteria. Workers and visitors appeared a relevant source of microbial contamination. Air biodiversity assayed by NGS seems a promising marker for studying IAQ. PMID:29123371
A Variation on the Use of Interactive Anonymous Quizzes in the Chemistry Classroom
ERIC Educational Resources Information Center
Wagner, Brian D.
2009-01-01
This article describes an interesting variation on the use of interactive anonymous quizzes (IAQs) in the chemistry classroom. In this variation, IAQs are used to introduce new material or topics in a course, as opposed to their traditional use for reviewing previously covered material. Two examples of IAQs used to introduce new topics in a…
Carpet vs. Hard Surface Floors: Studies Compare Health Effects of Each.
ERIC Educational Resources Information Center
Schmidt, Edward A.
1994-01-01
This article, third in a three-part series of articles that discuss indoor air quality (IAQ) issues affecting schools, looks at studies that compare the health effect of carpet and hard surface floors. Concludes that carpet is appropriate for use in schools when it is properly maintained. (MLF)
Latex paints are widely used in residential and commercial indoor environments. The surface areas covered by the paints in these environments are relatively large. Thus, latex paints have the potential for having a major impact on indoor air quality (IAQ). A study was undertaken ...
An indoor air quality evaluation in a residential retrofit project using spray polyurethane foam.
Tian, Shen; Ecoff, Scott; Sebroski, John; Miller, Jason; Rickenbacker, Harold; Bilec, Melissa
2018-05-01
Understanding of indoor air quality (IAQ) during and after spray polyurethane foam (SPF) application is essential to protect the health of both workers and building occupants. Previous efforts such as field monitoring, micro-chamber/spray booth emission studies, and fate/transport modeling have been conducted to understand the chemical exposure of SPF and guide risk mitigation strategies. However, each type of research has its limitation and can only reveal partial information on the relationship between SPF and IAQ. A comprehensive study is truly needed to integrate the experimental design and analytical testing methods in the field/chamber studies with the mathematical tools employed in the modeling studies. This study aims to bridge this gap and provide a more comprehensive understanding on the impact of SPF to IAQ. The field sampling plan of this research aims to evaluate the airborne concentrations of methylene diphenyl diisocyanate (MDI), formaldehyde, acetaldehyde, propionaldehyde, tris(1-chlor-2-propyl)phosphate (TCPP), trans-1-chloro-3,3,3-trifluoropropene (Solstice TM ), and airborne particles. Modifications to existing MDI sampling and analytical methods were made so that level of quantification was improved. In addition, key fate and transport modeling input parameters such as air changes per hour and airborne particle size distribution were measured. More importantly, TCPP accumulation onto materials was evaluated, which is important to study the fate and transport of semi-volatile organic compounds. The IAQ results showed that after spray application was completed in the entire building, airborne concentrations decreased for all chemicals monitored. However, it is our recommendation that during SPF application, no one should return to the application site without proper personal protection equipment as long as there are active spray activities in the building. The comparison between this field study and a recent chamber study proved surface sorption and particle deposition is an important factor in determining the fate of airborne TCPP. The study also suggests the need for further evaluation by employing mathematical models, proving the data generated in this work as informative to industry and the broader scientific community.
Should Title 24 Ventilation Requirements Be Amended to include an Indoor Air Quality Procedure?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dutton, Spencer M.; Mendell, Mark J.; Chan, Wanyu R.
Minimum outdoor air ventilation rates (VRs) for buildings are specified in standards, including California?s Title 24 standards. The ASHRAE ventilation standard includes two options for mechanically-ventilated buildings ? a prescriptive ventilation rate procedure (VRP) that specifies minimum VRs that vary among occupancy classes, and a performance-based indoor air quality procedure (IAQP) that may result in lower VRs than the VRP, with associated energy savings, if IAQ meeting specified criteria can be demonstrated. The California Energy Commission has been considering the addition of an IAQP to the Title 24 standards. This paper, based on a review of prior data and newmore » analyses of the IAQP, evaluates four future options for Title 24: no IAQP; adding an alternate VRP, adding an equivalent indoor air quality procedure (EIAQP), and adding an improved ASHRAE-like IAQP. Criteria were established for selecting among options, and feedback was obtained in a workshop of stakeholders. Based on this review, the addition of an alternate VRP is recommended. This procedure would allow lower minimum VRs if a specified set of actions were taken to maintain acceptable IAQ. An alternate VRP could also be a valuable supplement to ASHRAE?s ventilation standard.« less
Indoor air quality in schools and its relationship with children's respiratory symptoms
NASA Astrophysics Data System (ADS)
Madureira, Joana; Paciência, Inês; Rufo, João; Ramos, Elisabete; Barros, Henrique; Teixeira, João Paulo; de Oliveira Fernandes, Eduardo
2015-10-01
A cross-sectional survey was conducted to characterize the indoor air quality (IAQ) in schools and its relationship with children's respiratory symptoms. Concentrations of volatile organic compounds (VOC), aldehydes, PM2.5, PM10, carbon dioxide, bacteria and fungi were assessed in 73 classrooms from 20 public primary schools located in Porto, Portugal. Children who attended the selected classrooms (n = 1134) were evaluated by a standardised health questionnaire completed by the legal guardians; spirometry and exhaled nitric oxide tests. The results indicated that no classrooms presented individual VOC pollutant concentrations higher than the WHO IAQ guidelines or by INDEX recommendations; while PM2.5, PM10 and bacteria levels exceeded the WHO air quality guidelines or national limit values. High levels of total VOC, acetaldehyde, PM2.5 and PM10 were associated with higher odds of wheezing in children. Thus, indoor air pollutants, some even at low exposure levels, were related with the development of respiratory symptoms. The results pointed out that it is crucial to take into account the unique characteristics of the public primary schools, to develop appropriate control strategies in order to reduce the exposure to indoor air pollutants and, therefore, to minimize the adverse health effects.
Electronic cigarettes and indoor air quality: a review of studies using human volunteers.
Zainol Abidin, Najihah; Zainal Abidin, Emilia; Zulkifli, Aziemah; Karuppiah, Karmegam; Syed Ismail, Sharifah Norkhadijah; Amer Nordin, Amer Siddiq
2017-09-26
This paper is primarily aimed to review articles on electronic cigarettes (e-cigarettes) focusing on indoor air quality (IAQ) assessment that were conducted using human volunteers under natural settings that mimic actual vaping scenarios. Such studies may give a better representation of the actual potential exposure towards e-cigarettes emissions in indoor settings. A systematic literature search was conducted using PubMed search engine database. Search terms such as "electronic cigarette", "e-cigarette", "electronic nicotine delivery system", and "indoor air quality" were used to identify the relevant articles to be included in this review. Articles that involved human volunteers who were asked to vape in natural settings or settings that mimic the actual vaping scenario were chosen to be reviewed. The search yielded a total of 15 published articles. Eleven articles were excluded due to 1) unavailability of its full-text (n=1), 2) did not involve human volunteers (n=5) and 3) did not involve an IAQ study (n=5). Four articles were critically reviewed in this paper. From the four selected articles, two of the papers focused on the determination of nicotine level released by e-cigarettes whereas the other two covered IAQ parameters namely; particulate matters (PM), propylene glycols, formaldehyde, metals and polycyclic aromatic hydrocarbons (PAHs). Only two of the studies involved determination of biomarkers of exposure. The level of chemical contents released varied between studies. The differences in the brands of e-cigarette used, number of vapers recruited and the sensitivity of the methodologies employed in these studies may be the possible causes for such differences. However, studies using human volunteers conducted in a natural setting are more relevant to portray the actual exposure to vapors among e-cigarettes users and non-users compared to studies using a smoking machine/an exposure chamber. This is because such studies take into account the behavior of consumers and individual retention of nicotine. Such method will therefore avoid the possibility of overestimation in terms of exposures toward e-cigarettes users and non-users. There are limited e-cigarette studies on the impact of IAQ performed using human volunteers in natural settings. The available studies however, provided inconsistent scientific evidence on the actual exposure towards the vapor contents as unstandardized methodology were used in conducting such research. Therefore, there is a need to conduct IAQ studies in natural settings by using a standardized protocol in terms of the number of vapers recruited, the size of the indoor settings, the methods used in detecting and quantifying the contents and levels of emissions and the sensitivity of the equipment used in analyzing the contents. This will help in better utilization of the findings from such studies for the use of risk assessment of the exposures towards e-cigarette emissions. There is also a need to emphasize that it is the onus of the manufacturers in providing and proving scientifically sound safety claims for their products prior to commercializing it in the market.
Indoor air quality during renovation actions: a case study.
Abdel Hameed, A A; Yasser, I H; Khoder, I M
2004-09-01
A temporary renovation activity releases considerably high concentrations of particulate matter, viable and non-viable, into air. These pollutants are a potential contributor to unacceptable indoor air quality (IAQ). Particulate matter and its constituents lead, sulfate, nitrate, chloride, ammonium and fungi as well as fungal spores in air were evaluated in a building during renovation action. Suspended dust was recorded at a mean value of 6.1 mg m(-3) which exceeded the Egyptian limit values for indoor air (0.15 mg m(-3)) and occupational environments (5 mg m(-3)). The highest particle frequency (23%) of aerodynamic diameter (dae) was 1.7 microm. Particulate sulfate (SO(4)(2-)), nitrate (NO(3)(-)), chloride (Cl(-)), ammonium (NH(4)(+)) and lead components of suspended dust averaged 2960, 28, 1350, 100 and 13.3 microg m(-3), respectively. Viable fungi associated with suspended dust and that in air averaged 1.11 x 10(6) colony forming unit per gram (cfu g(-1)) and 92 colony forming unit per plate per hour (cfu p(-1) h(-1)), respectively. Cladosporium(33%), Aspergillus(25.6%), Alternaria(11.2%) and Penicillium(6.6%) were the most frequent fungal genera in air, whereas Aspergillus(56.8%), Penicillium(10.3%) and Eurotium(10.3%) were the most common fungal genera associated with suspended dust. The detection of Aureobasidium, Epicoccum, Exophiala, Paecilomyces, Scopulariopsis, Ulocladium and Trichoderma is an indication of moisture-damaged building materials. Alternaria, Aureobasidium, Cladosporium, Scopulariopsis and Nigrospora have dae > 5 microm whereas Aspergillus, Penicillium and Verticillium have dae < 5 microm which are suited to penetrate deeply into lungs. Particulate matter from the working area infiltrates the occupied zones if precautionary measures are inadequate. This may cause deterioration of IAQ, discomfort and acute health problems. Renovation should be carefully designed and managed, in order to minimize degradation of the indoor and outdoor air quality.
NASA Astrophysics Data System (ADS)
Ciuzas, Darius; Prasauskas, Tadas; Krugly, Edvinas; Sidaraviciute, Ruta; Jurelionis, Andrius; Seduikyte, Lina; Kauneliene, Violeta; Wierzbicka, Aneta; Martuzevicius, Dainius
2015-10-01
The study presents the characterization of dynamic patterns of indoor particulate matter (PM) during various pollution episodes for real-time IAQ management. The variation of PM concentrations was assessed for 20 indoor activities, including cooking related sources, other thermal sources, personal care and household products. The pollution episodes were modelled in full-scale test chamber representing a standard usual living room with the forced ventilation of 0.5 h-1. In most of the pollution episodes, the maximum concentration of particles in exhaust air was reached within a few minutes. The most rapid increase in particle concentration was during thermal source episodes such as candle, cigarette, incense stick burning and cooking related sources, while the slowest decay of concentrations was associated with sources, emitting ultrafine particle precursors, such as furniture polisher spraying, floor wet mopping with detergent etc. Placement of the particle sensors in the ventilation exhaust vs. in the centre of the ceiling yielded comparable results for both measured maximum concentrations and temporal variations, indicating that both locations were suitable for the placement of sensors for the management of IAQ. The obtained data provides information that may be utilized considering measurements of aerosol particles as indicators for the real-time management of IAQ.
Pesticides found in homes may result from indoor applications to control household pests or by translocation from outdoor sources. Pesticides disperse according to their physical properties and other factors such as human activity, residential air exchange, temperature and humi...
Pesticides found in homes may result from indoor applications to control household pests or by translocation from outdoor sources. Pesticides disperse according to their physical properties and other factors such as human activity, air exchange, temperature and humidity. Insect...
Epistemic assessment of radon level of offices in Hong Kong
NASA Astrophysics Data System (ADS)
Wong, L. T.; Mui, K. W.; Law, K. Y.; Hui, P. S.
People spend most of their life working indoors. Human exposure to various air pollutants changed its importance in nature from outdoor to indoor. As some of the pollutant sources basically originate from the building envelope that could not be removed or is costly to mitigate, the remaining questions are: how the indoor air quality (IAQ) is monitored and how the information could be used for the environmental control system to achieve the best air quality delivery. Indoor radon level could be measured with a number of sampling approaches and used to determine the acceptance of an IAQ with respect to certain exposure limits. In determining the acceptable IAQ of a space, this study proposes that the measured indoor radon level must be accompanied with the confidence levels of the assessment. Radon levels in Hong Kong offices were studied by a cross-sectional measurement in 216 typical offices and a year-round longitudinal measurement in one office. The results showed that 96.5% (94.0-99.0% at 95% confidence interval) and 98.6% (97.0% to >99.9% at 95% confidence interval) of the sampled offices would satisfy action radon levels of 150 and 200 Bq m -3, respectively. The same results were then used to quantify the prior knowledge on radon level distributions of an office and the probable errors of the adopted sampling schemes. This study proposes an epistemic approach, with the prior knowledge and a sample test result, to assess the acceptance against an action radon level of an office in Hong Kong. With the certainty of the test results determined for judgmental purposes, it is possible to apply the method to an office for follow-up tests of acceptance.
Carreiro-Martins, Pedro; Papoila, Ana Luisa; Caires, Iolanda; Azevedo, Susana; Cano, Maria Manuela; Virella, Daniel; Leiria-Pinto, Paula; Teixeira, João Paulo; Rosado-Pinto, José; Annesi-Maesano, Isabella; Neuparth, Nuno
2016-05-01
Scarce information is available about the relationships between indoor air quality (IAQ) at day care centers (DCC), the estimated predisposition for asthma, and the actual wheezing susceptibility. In the Phase II of ENVIRH study, 19 DCC were recruited after cluster analysis. Children were evaluated firstly using the ISAAC questionnaire and later by a follow-up questionnaire about recent wheezing. A positive asthma predictive index (API) was considered as predisposition for asthma. Every DCC was audited for IAQ and monitored for chemical and biologic contaminants. We included 1191 children, with a median age of 43 (P25 -P75 : 25-58) months. Considering the overall sample, in the first questionnaire, associations were found between CO2 concentration (increments of 200 ppm) and diagnosis of asthma (OR: 1.10; 95% CI: 1.00-1.20). Each increment of 100 μg/m(3) of total volatile organic compounds (TVOC) and 1 μg of Der p1/g of dust were associated with wheezing in the previous 12 months (OR: 1.06; 95% CI: 1.01-1.11 and OR: 1.06; 95% CI: 0.99-1.12, respectively). In the follow-up questionnaire, TVOC were again associated with wheezing (OR: 1.05; 95% CI: 1.00-1.11). Children exposed to fungal concentration above the 75th percentile had also higher odds of wheezing at follow-up. TVOC were associated with wheezing in children with either negative or positive API. IAQ in DCC seems to be associated with wheezing, in children with and without predisposition for asthma. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Cold air systems: Sleeping giant
DOE Office of Scientific and Technical Information (OSTI.GOV)
MacCracken, C.D.
1994-04-01
This article describes how cold air systems help owners increase the profits from their buildings by reducing electric costs and improving indoor air quality through lower relative humidity levels. Cold air distribution involves energy savings, cost savings, space savings, greater comfort, cleaner air, thermal storage, tighter ducting, coil redesign, lower relative humidities, retrofitting, and improved indoor air quality (IAQ). It opens a door for architects, engineers, owners, builders, environmentalists, retrofitters, designers, occupants, and manufacturers. Three things have held up cold air's usage: multiple fan-powered boxes that ate up the energy savings of primary fans. Cold air room diffusers that providedmore » inadequate comfort. Condensation from ducts, boxes, and diffusers. Such problems have been largely eliminated through research and development by utilities and manufacturers. New cold air diffusers no longer need fan powered boxes. It has also been found that condensation is not a concern so long as the ducts are located in air conditioned space, such as drop ceilings or central risers, where relative humidity falls quickly during morning startup.« less
Barnes, Natasha Maria; Ng, Tsz Wai; Ma, Kwok Keung; Lai, Ka Man
2018-03-27
Many people spend lengthy periods each day in enclosed vehicles in Hong Kong. However, comparably limited data is available about in-cabin air quality in air-conditioned private vehicles, and the car usage that may affect the air quality. Fifty-one vehicles were tested for particulate matter (PM 0.3 and PM 2.5 ), total volatile organic compounds (TVOCs), carbon monoxide (CO), carbon dioxide (CO₂), airborne bacteria, and fungi levels during their routine travel journey. Ten of these vehicles were further examined for PM 0.3 , PM 2.5 , TVOCs, CO, and CO₂ during engine idling. In general, during driving PM 2.5 levels in-cabin reduced overtime, but not PM 0.3 . For TVOCs, 24% vehicles exceeded the recommended Indoor Air Quality (IAQ) level in offices and public places set by the Hong Kong Environmental Protection Department. The total volatile organic compounds (TVOC) concentration positively correlated with the age of the vehicle. Carbon monoxide (CO) levels in all of the vehicles were lower than the IAQ recommendation, while 96% vehicles exceeded the recommended CO₂ level of 1000 ppmv; 16% vehicles >5000 ppmv. Microbial counts were relatively low. TVOCs levels at idle engine were higher than that during driving. Although the time we spend in vehicles is short, the potential exposure to high levels of pollutants should not be overlooked.
Barnes, Natasha Maria; Ng, Tsz Wai; Ma, Kwok Keung; Lai, Ka Man
2018-01-01
Many people spend lengthy periods each day in enclosed vehicles in Hong Kong. However, comparably limited data is available about in-cabin air quality in air-conditioned private vehicles, and the car usage that may affect the air quality. Fifty-one vehicles were tested for particulate matter (PM0.3 and PM2.5), total volatile organic compounds (TVOCs), carbon monoxide (CO), carbon dioxide (CO2), airborne bacteria, and fungi levels during their routine travel journey. Ten of these vehicles were further examined for PM0.3, PM2.5, TVOCs, CO, and CO2 during engine idling. In general, during driving PM2.5 levels in-cabin reduced overtime, but not PM0.3. For TVOCs, 24% vehicles exceeded the recommended Indoor Air Quality (IAQ) level in offices and public places set by the Hong Kong Environmental Protection Department. The total volatile organic compounds (TVOC) concentration positively correlated with the age of the vehicle. Carbon monoxide (CO) levels in all of the vehicles were lower than the IAQ recommendation, while 96% vehicles exceeded the recommended CO2 level of 1000 ppmv; 16% vehicles >5000 ppmv. Microbial counts were relatively low. TVOCs levels at idle engine were higher than that during driving. Although the time we spend in vehicles is short, the potential exposure to high levels of pollutants should not be overlooked. PMID:29584686
Sharma, Manju; O'Connell, Susan; Garelli, Brett; Sattayatewa, Chakkrid; Moschandreas, Demetrios; Pagilla, Krishna
2012-01-01
Indoor air quality (IAQ) and odors were determined using sampling/monitoring, measurement, and modeling methods in a large dewatering building at a very large water reclamation plant. The ultimate goal was to determine control strategies to reduce the sensory impacts on the workforce and achieve odor reduction within the building. Study approaches included: (1) investigation of air mixing by using CO(2) as an indicator, (2) measurement of airflow capacity of ventilation fans, (3) measurement of odors and odorants, (4) development of statistical and IAQ models, and (5) recommendation of control strategies. The results showed that air quality in the building complies with occupational safety and health guidelines; however, nuisance odors that can increase stress and productivity loss still persist. Excess roof fan capacity induced odor dispersion to the upper levels. Lack of a local air exhaust system of sufficient capacity and optimum design was found to be the contributor to occasional less than adequate indoor air quality and odors. Overall, air ventilation rate in the building has less effect on persistence of odors in the building. Odor/odorant emission rates from centrifuge drops were approximately 100 times higher than those from the open conveyors. Based on measurements and modeling, the key control strategies recommended include increasing local air exhaust system capacity and relocation of exhaust hoods closer to the centrifuge drops.
Van Ryswyk, K; Wallace, L; Fugler, D; MacNeill, M; Héroux, M È; Gibson, M D; Guernsey, J R; Kindzierski, W; Wheeler, A J
2015-01-01
Residential air exchange rates (AERs) are vital in understanding the temporal and spatial drivers of indoor air quality (IAQ). Several methods to quantify AERs have been used in IAQ research, often with the assumption that the home is a single, well-mixed air zone. Since 2005, Health Canada has conducted IAQ studies across Canada in which AERs were measured using the perfluorocarbon tracer (PFT) gas method. Emitters and detectors of a single PFT gas were placed on the main floor to estimate a single-zone AER (AER1z). In three of these studies, a second set of emitters and detectors were deployed in the basement or second floor in approximately 10% of homes for a two-zone AER estimate (AER2z). In total, 287 daily pairs of AER2z and AER1z estimates were made from 35 homes across three cities. In 87% of the cases, AER2z was higher than AER1z. Overall, the AER1z estimates underestimated AER2z by approximately 16% (IQR: 5–32%). This underestimate occurred in all cities and seasons and varied in magnitude seasonally, between homes, and daily, indicating that when measuring residential air exchange using a single PFT gas, the assumption of a single well-mixed air zone very likely results in an under prediction of the AER. PMID:25399878
Assessment of indoor levels of volatile organic compounds and carbon dioxide in schools in Kuwait.
Al-Awadi, Layla
2018-01-01
Indoor air quality (IAQ) in schools is a matter of concern because children are most vulnerable and sensitive to pollutant exposure. Conservation of energy at the expense of ventilation in heating, ventilation, and air conditioning (HVAC) systems adversely affects IAQ. Extensive use of new materials in building, fitting, and refurbishing emit various pollutants such that the indoor environment creates its own discomfort and health risks. Various schools in Kuwait were selected to assess their IAQ. Comprehensive measurements of volatile organic compounds (VOCs) consisting of 72 organic compounds consisting of aliphatic (C 3 -C 6 ), aromatic (C 6 -C 9 ), halogenated (C 1 -C 7 ), and oxygenated (C 2 -C 9 ) functional groups in indoor air were made for the first time in schools in Kuwait. The concentrations of indoor air pollutants revealed hot spots (science preparation rooms, science laboratories, arts and crafts classes/paint rooms, and woodworking shops/decoration rooms where local sources contributed to the buildup of pollutants in each school. The most abundant VOC pollutant was chlorodifluoromethane (R22; ClF 2 CH), which leaked from air conditioning (AC) systems due to improper operation and maintenance. The other copious VOCs were alcohols and acetone at different locations due to improper handling of the chemicals and their excessive uses as solvents. Indoor carbon dioxide (CO 2 ) levels were measured, and these levels reflected the performance of HVAC systems; a specific rate or lack of ventilation affected the IAQ. Recommendations are proposed to mitigate the buildup of indoor air pollutants at school sites. Indoor air quality in elementary schools has been a subject of extreme importance due to susceptibility and sensibility of children to air pollutants. The schools were selected based on their surrounding environment especially downwind direction from the highly industrialized zone in Kuwait. Extensive sampling from different sites in four schools for comprehensive VOCs and CO 2 were completed for an extended period of over a year. Different hot spots were identified where leaked refrigerant and inadequate handling of laboratory solvents contributed to the high VOCs in the respective locations. CO 2 levels reflected HVAC performance and poor ventilation. A list of recommendations has been proposed to eradicate these high levels of air pollution.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Widder, Sarah H.; Chamness, Michele A.; Petersen, Joseph M.
2014-10-01
To improve the indoor air quality in new, high performance homes, a variety of standards and rating programs have been introduced to identify building materials that are designed to have lower emission rates of key contaminants of concern and a number of building materials are being introduced that are certified to these standards. For example, the U.S. Department of Energy (DOE) Zero Energy Ready Home program requires certification under the U.S. Environmental Protection Agency (EPA) Indoor airPLUS (IaP) label, which requires the use of PS1 or PS2 certified plywood and OSB; low-formaldehyde emitting wood products; low- or no-VOC paints andmore » coatings as certified by Green Seal Standard GS-11, GreenGuard, SCS Indoor Advantage Gold Standard, MPI Green Performance Standard, or another third party rating program; and Green Label-certified carpet and carpet cushions. However, little is known regarding the efficacy of the IAP requirements in measurably reducing contaminant exposures in homes. The goal of this project is to develop a robust experimental approach and collect preliminary data to support the evaluation of indoor air quality (IAQ) measures linked to IAP-approved low-emitting materials and finishes in new residential homes. To this end, the research team of Pacific Northwest National Laboratory (PNNL) and Lawrence Berkeley National Laboratory (LBNL) developed a detailed experimental plan to measure IAQ constituents and other parameters, over time, in new homes constructed with materials compliant with IAP’s low-emitting material and ventilation requirements (i.e., section 6.1, 6.2, 6.3, and 7.2) and similar homes constructed to the state building code with conventional materials. The IAQ in IAP and conventional homes of similar age, location, and construction style is quantified as the differences in the speciated VOC and aldehyde concentrations, normalized to dilution rates. The experimental plan consists of methods to evaluate the difference between low-emitting and “conventional” materials as installed in newly constructed residential homes using both (1) highly controlled, short-term active samples to precisely characterize the building-related chemical emissions and building contents and (2) a week-long passive sample designed to capture the impact of occupant behavior and related activities on measured IAQ contaminant levels indoors. The combination of detailed short-term measurements with the home under controlled/consistent conditions during pre- and post-occupancy and the week-long passive sampling data provide the opportunity to begin to separate the different emission sources and help isolate and quantify variability in the monitored homes. Between April and August 2014, the research team performed pre-occupancy and post-occupancy sampling in one conventional home and two homes built with low-emitting materials that were generally consistent with EPA’s Indoor airPLUS guidelines. However, for a number of reasons, the full experimental plan was not implemented. The project was intended to continue for up to three years to asses long-term changes in IAQ but the project was limited to one calendar year. As a result, several of the primary research questions related to seasonal impacts and the long-term trends in IAQ could not be addressed. In addition, there were several unexpected issues related to recruiting, availability of home types, and difficulty coordinating with builders/realtors/homeowners. Several field monitoring issues also came up that provide “lessons learned” that led to improvements to the original monitoring plan. The project produced a good experimental plan that is expected to be be useful for future efforts collecting data to support answering these same or similar research questions.« less
Khalequzzaman, Md; Kamijima, Michihiro; Sakai, Kiyoshi; Ebara, Takeshi; Hoque, Bilqis Amin; Nakajima, Tamie
2011-11-01
Indoor air pollutants from biomass combustion pose a risk for respiratory diseases in children. It is plausible that distinct differences in the indoor air quality (IAQ) exist between urban and rural areas in developing countries since the living environment between these two areas are quite different. We have investigated possible differences in IAQ in urban and rural Dhaka, Bangladesh and the association of such differences with the incidence of respiratory and some non-respiratory symptoms in children of families using biomass fuel. Indoor air concentrations of carbon monoxide (CO), carbon dioxide (CO(2)), dust particles, volatile organic compounds (VOCs), and nitrogen dioxide were measured once in the winter and once in the summer of 2008. Health data on 51 urban and 51 rural children under 5 years of age from 51 families in each area were collected once a week starting in the winter and continuing to the summer of 2008. Mean concentrations of CO, CO(2,), dust particles, and major VOCs were significantly higher in urban kitchens than in rural ones (p < 0.05). The incidence rate ratio (IRR) suggests that compared to the urban children, the children in the rural area suffered significantly more from respiratory symptoms [IRR 1.63, 95% confidence interval (CI) 1.62-1.64], skin itchiness (IRR 3.3, 95% CI 1.9-5.7), and diarrhea (IRR 1.8, 95% CI 1.4-2.4), while fewer experienced fever (IRR 0.5, 95% CI 0.4-0.6). No difference was observed for other symptoms. We found lower IAQ in the homes of urban biomass fuel-users compared to rural ones in Bangladesh but could not attribute the occurrence of respiratory symptoms among children to the measured IAQ. Other factors may be involved.
Ye, Wei; Zhang, Xu; Gao, Jun; Cao, Guangyu; Zhou, Xiang; Su, Xing
2017-05-15
After nearly twenty years of rapid modernization and urbanization in China, huge achievements have transformed the daily lives of the Chinese people. However, unprecedented environmental consequences in both indoor and outdoor environments have accompanied this progress and have triggered public awareness and demands for improved living standards, especially in residential environments. Indoor pollution data measured for >7000 dwellings (approximately 1/3 were newly decorated and were tested for volatile organic compound (VOC) measurements, while the rest were tested for particles, phthalates and other semi-volatile organic compounds (SVOCs), moisture/mold, inorganic gases and radon) in China within the last ten years were reviewed, summarized and compared with indoor concentration recommendations based on sensory or health end-points. Ubiquitous pollutants that exceed the concentration recommendations, including particulate matter, formaldehyde, benzene and other VOCs, moisture/mold, inorganic gases and radon, were found, indicating a common indoor air quality (IAQ) issue in Chinese dwellings. With very little prevention, oral, inhalation and dermal exposure to those pollutants at unhealthy concentration levels is almost inevitable. CO 2 , VOCs, humidity and radon can serve as ventilation determinants, each with different ventilation demands and strategies, at typical occupant densities in China; and particle reduction should be a prerequisite for determining ventilation requirements. Two directional ventilation modes would have profound impacts on improving IAQ for Chinese residences are: 1) natural (or window) ventilation with an air cleaner and 2) mechanical ventilation with an air filtration unit, these two modes were reviewed and compared for their applicability and advantages and disadvantages for reducing human exposure to indoor air pollutants. In general, mode 2 can more reliably ensure good IAQ for occupants; while mode 1 is more applicable due to its low cost and low energy consumption. However, besides a roadmap, substantial efforts are still needed to develop affordable, applicable and general ventilation solutions to improve the IAQ of residential buildings in China. Copyright © 2017 Elsevier B.V. All rights reserved.
Bonetta, Sa; Bonetta, Si; Mosso, S; Sampò, S; Carraro, E
2010-02-01
The purpose of this study was to evaluate the level and composition of bacteria and fungi in the indoor air of an Italian office building equipped with a heating, ventilation and air conditioning (HVAC) system. Airborne bacteria and fungi were collected in three open-space offices during different seasons. The microbial levels in the outdoor air, supply air diffusers, fan coil air flow and air treatment unit humidification water tank were used to evaluate the influence of the HVAC system on indoor air quality (IAQ). A medium-low level of bacterial contamination (50-500 CFU/m(3)) was found in indoor air. Staphylococcus and Micrococcus were the most commonly found genera, probably due to human presence. A high fungal concentration was measured due to a flood that occurred during the winter. The indoor seasonal distribution of fungal genera was related to the fungal outdoor distribution. Significant seasonal and daily variation in airborne microorganisms was found, underlining a relationship with the frequency of HVAC system switching on/off. The results of this monitoring highlight the role of the HVAC system on IAQ and could be useful to better characterise bacterial and fungal population in the indoor air of office buildings.
Frey, Sarah E; Destaillats, Hugo; Cohn, Sebastian; Ahrentzen, Sherry; Fraser, Matthew P
2014-11-01
A survey of key indoor air quality (IAQ) parameters and resident health was carried out in 72 apartments within a single low-income senior housing building in Phoenix, Arizona. Air sampling was carried out simultaneously with a questionnaire on personal habits and general health of residents. Mean PM10 concentrations are 66 +/- 16, 58 +/- 13, and 24 +/- 3 microg/m3 and mean PM2.5 concentrations are 62 +/- 16, 53 +/- 13, and 20 +/- 2 microg/m3 for the living room, kitchen, and outdoor balcony, respectively. Median PM10 concentrations are 17, 18 and 17 microg/m3 and median PM25 concentrations are 13, 14, and 13 microg/m3, respectively. The initial results indicate that increased indoor particle concentrations coincide with residents who report smoking cigarettes. Indoor formaldehyde concentrations revealed median levels of 36.9, 38.8, and 4.3 ppb in the living room, kitchen, and balcony, respectively. Results show that 36% of living room samples and 44% of kitchen samples exceeded the Health Canada REL for chronic exposure to formaldehyde (40 ppb). Associations between occupants' behavior self-reported health conditions, and IAQ are evaluated.
Effects of antimicrobial treatment on fiberglass-acrylic filters.
Cecchini, C; Verdenelli, M C; Orpianesi, C; Dadea, G M; Cresci, A
2004-01-01
The aims of the present study were to: (i) analyse a group of antimicrobial agents and to select the most active against test microbial strains; (ii) test the effect of the antimicrobial treatment on air filters in order to reduce microbial colonization. Different kinds of antimicrobial agents were analysed to assess their compatibility with the production process of air filter media. The minimal inhibitory concentration for each antimicrobial agent was determined against a defined list of microbial strains, and an antimicrobial activity assay of filter prototypes was developed to determine the most active agent among the compatible antimicrobials. Then, the most active was chosen and added directly to the filter during the production process. The microbial colonization of treated and untreated filter media was assessed at different working times for different incubation times by stereomicroscope and scanning electron microscope analysis. Some of the antimicrobial agents analysed were more active against microbial test strains and compatible with the production process of the filter media. Filter sections analysis of treated filter media showed a significantly lower microbial colonization than those untreated, a reduction of species both in density and varieties and of the presence of bacteria and fungal hyphae with reproductive structures. This study demonstrated the ability of antimicrobial treatments to inhibit the growth of micro-organisms in filter media and subsequently to increase indoor air quality (IAQ), highlighting the value of adding antimicrobials to filter media. To make a contribution to solving the problem of microbial contamination of air filters, by demonstrating the efficacy of incorporating antimicrobial agents in the filter media to improve IAQ and health.
Short-term airing by natural ventilation - modeling and control strategies.
Perino, M; Heiselberg, P
2009-10-01
The need to improve the energy efficiency of buildings requires new and more efficient ventilation systems. It has been demonstrated that innovative operating concepts that make use of natural ventilation seem to be more appreciated by occupants. This kind of system frequently integrates traditional mechanical ventilation components with natural ventilation devices, such as motorized windows and louvers. Among the various ventilation strategies that are currently available, buoyancy driven single-sided natural ventilation has proved to be very effective and can provide high air change rates for temperature and IAQ control. However, in order to promote a wider applications of these systems, an improvement in the knowledge of their working principles and the availability of new design and simulation tools is necessary. In this context, the paper analyses and presents the results of a research that was aimed at developing and validating numerical models for the analysis of buoyancy driven single-sided natural ventilation systems. Once validated, these models can be used to optimize control strategies in order to achieve satisfactory indoor comfort conditions and IAQ. Practical Implications Numerical and experimental analyses have proved that short-term airing by intermittent ventilation is an effective measure to satisfactorily control IAQ. Different control strategies have been investigated to optimize the capabilities of the systems. The proposed zonal model has provided good performances and could be adopted as a design tool, while CFD simulations can be profitably used for detailed studies of the pollutant concentration distribution in a room and to address local discomfort problems.
Kadiyala, Akhil; Kaur, Devinder; Kumar, Ashok
2013-02-01
The present study developed a novel approach to modeling indoor air quality (IAQ) of a public transportation bus by the development of hybrid genetic-algorithm-based neural networks (also known as evolutionary neural networks) with input variables optimized from using the regression trees, referred as the GART approach. This study validated the applicability of the GART modeling approach in solving complex nonlinear systems by accurately predicting the monitored contaminants of carbon dioxide (CO2), carbon monoxide (CO), nitric oxide (NO), sulfur dioxide (SO2), 0.3-0.4 microm sized particle numbers, 0.4-0.5 microm sized particle numbers, particulate matter (PM) concentrations less than 1.0 microm (PM10), and PM concentrations less than 2.5 microm (PM2.5) inside a public transportation bus operating on 20% grade biodiesel in Toledo, OH. First, the important variables affecting each monitored in-bus contaminant were determined using regression trees. Second, the analysis of variance was used as a complimentary sensitivity analysis to the regression tree results to determine a subset of statistically significant variables affecting each monitored in-bus contaminant. Finally, the identified subsets of statistically significant variables were used as inputs to develop three artificial neural network (ANN) models. The models developed were regression tree-based back-propagation network (BPN-RT), regression tree-based radial basis function network (RBFN-RT), and GART models. Performance measures were used to validate the predictive capacity of the developed IAQ models. The results from this approach were compared with the results obtained from using a theoretical approach and a generalized practicable approach to modeling IAQ that included the consideration of additional independent variables when developing the aforementioned ANN models. The hybrid GART models were able to capture majority of the variance in the monitored in-bus contaminants. The genetic-algorithm-based neural network IAQ models outperformed the traditional ANN methods of the back-propagation and the radial basis function networks. The novelty of this research is the development of a novel approach to modeling vehicular indoor air quality by integration of the advanced methods of genetic algorithms, regression trees, and the analysis of variance for the monitored in-vehicle gaseous and particulate matter contaminants, and comparing the results obtained from using the developed approach with conventional artificial intelligence techniques of back propagation networks and radial basis function networks. This study validated the newly developed approach using holdout and threefold cross-validation methods. These results are of great interest to scientists, researchers, and the public in understanding the various aspects of modeling an indoor microenvironment. This methodology can easily be extended to other fields of study also.
Webinar: A Proactive Approach to IAQ: Saving Money and Protecting Health With Preventive Maintenance
A page to register to view the June 22, 2017, webinar in the IAQ Knowledge-to-Action Professional Training Webinar Series: Green Cleaning for Improved Health: The Return on Investment of Green Cleaning in Schools
A page to register to view the February 22, 2018, Energy Savings Plus Health for Schools Webinar Series Webinar: Making the Connection: Linking IAQ, Energy Efficiency and Preventive Maintenance Together for Healthy Schools
Dorizas, Paraskevi Vivian; Assimakopoulos, Margarita-Niki; Santamouris, Mattheos
2015-05-01
The perception of the indoor environmental quality (IEQ) through questionnaires in conjunction with in-field measurements related to the indoor air quality (IAQ), the thermal comfort and the lighting environment were studied in nine naturally ventilated schools of Athens, Greece. Cluster analysis was carried out in order to determine the ranges of indoor air pollutants, temperature (T), relative humidity (RH), and ventilation rates at which the students were satisfied with the indoor environment. It was found that increased levels of particulate matter did not have a negative effect on students' perception while students seemed to link the degradation of IAQ with temperature variations. Statistically significant correlations were further found between measurement results and students' perception of the IEQ. Students' sick building syndrome (SBS) symptoms and performance of schoolwork were also investigated as a function of the levels of indoor air pollutants and ventilation, and there were found significant positive correlations between particulate matter (PM) and certain health symptoms. Students' learning performance seemed to be affected by the ventilation rates and carbon dioxide (CO₂) concentrations while certain health effects positively correlated to the levels of PM and CO₂. The energy consumption of schools was rather low compared to other national findings, and both the electricity and oil consumption for heating positively correlated to the levels of indoor air pollutants.
A page to register to view the June 22, 2017, webinar in the IAQ Knowledge-to-Action Professional Training Webinar Series: Green Cleaning for Improved Health: The Return on Investment of Green Cleaning in Schools
Matic, Branislava; Rakic, Uros; Jovanovic, Verica; Dejanovic, Snezana; Djonovic, Nela
2017-01-01
Abstract Introduction Indoor air quality (IAQ) is rated as a serious public health issue. Knowing children are accounted as more vulnerable to environmental health hazards, data are needed on air quality in schools. Methods A project was conducted from 2007 until 2009 (SEARCH, School Environment and Respiratory Health of Children), aiming to verify links between IAQ and children’s respiratory health. Study was conducted in ten primary schools on 735 children, in 44 classrooms. Children were randomly selected. Research tools and indicators used for children’s exposure to school environment were indoor and outdoor pollutants, two standardized questionnaires for school and classroom characteristics. In both classroom air and ambient air in front of them we measured, during a 5-day exposure period for continuous 24h measuring: carbon monoxide, carbon dioxide, indoor air temperature, relative humidity, and PM10 during classes. Results PM10 concentrations were significantly most frequent in an interval of ≥80.1μg/m3, that is, in the interval above 50μg/m3. Mean PM10 value was 82.24±42.43 μg/m3, ranging from 32.00μg/m3 to of 197.00μg/m3. Conclusion The increase of outdoor PM10 concentration significantly affects the increase of indoor PM10. A statistically significant difference exists for average IAQ PM10 concentrations vs. indicators of indoor thermal comfort zone (p<0.0001); they are lower in the classrooms with indicators within the comfort zone. Moreover, dominant factors for the increase of PM10 are: high occupancy rate in the classroom (<2m2 of space per child), high relative humidity (>75%), and indoor temperature beyond 23°C, as well as bad ventilation habits (keeping windows shut most of the time). PMID:29062397
Van Ryswyk, K; Wallace, L; Fugler, D; MacNeill, M; Héroux, M È; Gibson, M D; Guernsey, J R; Kindzierski, W; Wheeler, A J
2015-12-01
Residential air exchange rates (AERs) are vital in understanding the temporal and spatial drivers of indoor air quality (IAQ). Several methods to quantify AERs have been used in IAQ research, often with the assumption that the home is a single, well-mixed air zone. Since 2005, Health Canada has conducted IAQ studies across Canada in which AERs were measured using the perfluorocarbon tracer (PFT) gas method. Emitters and detectors of a single PFT gas were placed on the main floor to estimate a single-zone AER (AER(1z)). In three of these studies, a second set of emitters and detectors were deployed in the basement or second floor in approximately 10% of homes for a two-zone AER estimate (AER(2z)). In total, 287 daily pairs of AER(2z) and AER(1z) estimates were made from 35 homes across three cities. In 87% of the cases, AER(2z) was higher than AER(1z). Overall, the AER(1z) estimates underestimated AER(2z) by approximately 16% (IQR: 5-32%). This underestimate occurred in all cities and seasons and varied in magnitude seasonally, between homes, and daily, indicating that when measuring residential air exchange using a single PFT gas, the assumption of a single well-mixed air zone very likely results in an under prediction of the AER. The results of this study suggest that the long-standing assumption that a home represents a single well-mixed air zone may result in a substantial negative bias in air exchange estimates. Indoor air quality professionals should take this finding into consideration when developing study designs or making decisions related to the recommendation and installation of residential ventilation systems. © 2014 Her Majesty the Queen in Right of Canada. Indoor Air published by John Wiley & Sons Ltd Reproduced with the permission of the Minister of Health Canada.
An Indoor Monitoring System for Ambient Assisted Living Based on Internet of Things Architecture
Marques, Gonçalo; Pitarma, Rui
2016-01-01
The study of systems and architectures for ambient assisted living (AAL) is undoubtedly a topic of great relevance given the aging of the world population. The AAL technologies are designed to meet the needs of the aging population in order to maintain their independence as long as possible. As people typically spend more than 90% of their time in indoor environments, indoor air quality (iAQ) is perceived as an imperative variable to be controlled for the inhabitants’ wellbeing and comfort. Advances in networking, sensors, and embedded devices have made it possible to monitor and provide assistance to people in their homes. The continuous technological advancements make it possible to build smart objects with great capabilities for sensing and connecting several possible advancements in ambient assisted living systems architectures. Indoor environments are characterized by several pollutant sources. Most of the monitoring frameworks instantly accessible are exceptionally costly and only permit the gathering of arbitrary examples. iAQ is an indoor air quality system based on an Internet of Things paradigm that incorporates in its construction Arduino, ESP8266, and XBee technologies for processing and data transmission and micro sensors for data acquisition. It also allows access to data collected through web access and through a mobile application in real time, and this data can be accessed by doctors in order to support medical diagnostics. Five smaller scale sensors of natural parameters (air temperature, moistness, carbon monoxide, carbon dioxide, and glow) were utilized. Different sensors can be included to check for particular contamination. The results reveal that the system can give a viable indoor air quality appraisal in order to anticipate technical interventions for improving indoor air quality. Indeed indoor air quality might be distinctively contrasted with what is normal for a quality living environment. PMID:27869682
An Indoor Monitoring System for Ambient Assisted Living Based on Internet of Things Architecture.
Marques, Gonçalo; Pitarma, Rui
2016-11-17
The study of systems and architectures for ambient assisted living (AAL) is undoubtedly a topic of great relevance given the aging of the world population. The AAL technologies are designed to meet the needs of the aging population in order to maintain their independence as long as possible. As people typically spend more than 90% of their time in indoor environments, indoor air quality (iAQ) is perceived as an imperative variable to be controlled for the inhabitants' wellbeing and comfort. Advances in networking, sensors, and embedded devices have made it possible to monitor and provide assistance to people in their homes. The continuous technological advancements make it possible to build smart objects with great capabilities for sensing and connecting several possible advancements in ambient assisted living systems architectures. Indoor environments are characterized by several pollutant sources. Most of the monitoring frameworks instantly accessible are exceptionally costly and only permit the gathering of arbitrary examples. iAQ is an indoor air quality system based on an Internet of Things paradigm that incorporates in its construction Arduino, ESP8266, and XBee technologies for processing and data transmission and micro sensors for data acquisition. It also allows access to data collected through web access and through a mobile application in real time, and this data can be accessed by doctors in order to support medical diagnostics. Five smaller scale sensors of natural parameters (air temperature, moistness, carbon monoxide, carbon dioxide, and glow) were utilized. Different sensors can be included to check for particular contamination. The results reveal that the system can give a viable indoor air quality appraisal in order to anticipate technical interventions for improving indoor air quality. Indeed indoor air quality might be distinctively contrasted with what is normal for a quality living environment.
Federal Research and Development Agenda for Net-Zero Energy, High-Performance Green Buildings
2008-10-21
transportation combined by 2050 (DOE 2007a). Figure 1. Energy Consumption in the United States Source: 2007 DOE Buildings Energy Data Book , Tables...poor indoor air quality (IAQ) include Legionnaires’ disease, heart disease and lung cancer from secondhand smoke, and carbon monoxide poisoning. More...www.eere.energy.gov/buildings/publications/pdfs/highperformance/commercialbuildin gsroadmap.pdf DOE. 2007a. Buildings energy data book . http
Batterman, S.; Du, L.; Mentz, G.; Mukherjee, B.; Parker, E.; Godwin, C.; Chin, J.-Y.; O'Toole, A.; Robins, T.; Rowe, Z.; Lewis, T.
2014-01-01
This study, a randomized controlled trial, evaluated the effectiveness of free-standing air filters and window air conditioners (ACs) in 126 low-income households of children with asthma. Households were randomized into a control group, a group receiving a free-standing HEPA filter placed in the child's sleeping area, and a group receiving the filter and a window-mounted AC. Indoor air quality (IAQ) was monitored for week-long periods over three to four seasons. High concentrations of particulate matter (PM) and carbon dioxide were frequently seen. When IAQ was monitored, filters reduced PM levels in the child's bedroom by an average of 50%. Filter use varied greatly among households and declined over time, for example, during weeks when pollutants were monitored, filter use was initially high, averaging 84 ± 27%, but dropped to 63 ± 33% in subsequent seasons. In months when households were not visited, use averaged only 34 ± 30%. Filter effectiveness did not vary in homes with central or room ACs. The study shows that measurements over multiple seasons are needed to characterize air quality and filter performance. The effectiveness of interventions using free-standing air filters depends on occupant behavior, and strategies to ensure filter use should be an integral part of interventions. PMID:22145709
Angelon-Gaetz, K A; Richardson, D B; Lipton, D M; Marshall, S W; Lamb, B; LoFrese, T
2015-12-01
Both high and low indoor relative humidity (RH) directly impact Indoor Air Quality (IAQ), an important school health concern. Prior school studies reported a high prevalence of mold, roaches, and water damage; however, few examined associations between modifiable classroom factors and RH, a quantitative indicator of dampness. We recorded RH longitudinally in 134 North Carolina classrooms (n = 9066 classroom-days) to quantify the relationships between modifiable classroom factors and average daily RH below, within, or above levels recommended to improve school IAQ (30-50% or 30-60% RH). The odds of having high RH (>60%) were 5.8 [95% Confidence Interval (CI): 2.9, 11.3] times higher in classrooms with annual compared to quarterly heating, ventilating, and air-conditioning (HVAC) system maintenance and 2.5 (95% CI: 1.5, 4.2) times higher in classrooms with HVAC economizers compared to those without economizers. Classrooms with direct-expansion split systems compared to chilled water systems had 2.7 (95% CI: 1.7, 4.4) times higher odds of low RH (<30%). When unoccupied, classrooms with thermostat setbacks had 3.7 (95% CI: 1.7, 8.3) times the odds of high RH (>60%) of those without setbacks. This research suggests actionable decision points for school design and maintenance to prevent high or low classroom RH. This study combines longitudinal measurements of classroom relative humidity with school inspection data from several schools to describe the problem of relative humidity control in schools. Our findings on how maintenance and mechanical factors affect classroom humidity provide suggestions on building operations policies and heating, ventilating, and air-conditioning (HVAC) design considerations that may improve classroom relative humidity control. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Federal R&D Agenda for Net Zero Energy, High-Performance Green Buildings
2008-09-30
Source: 2007 DOE Buildings Energy Data Book . Tables 1.1.3, 1.2.3, 1.3.3 Energy consumption associated with buildings has a substantial impact on...from poor indoor air quality (IAQ) include Legionnaire’s disease, heart disease and lung cancer from secondhand smoke, and carbon monoxide poisoning...publications/pdfs/highperformance/commercialbuildi ngsroadmap.pdf DOE. 2007a. Buildings energy data book . http://buildingsdatabook.eren.doe.gov/ DOE
The International AIDS Questionnaire-English Version (IAQ-E): Assessing the Validity and Reliability
ERIC Educational Resources Information Center
Davis, Cindy; Sloan, Melissa; MacMaster, Samuel; Hughes, Leslie
2006-01-01
In order to address HIV infection among college students, a comprehensive measure is needed that can be used with samples from culturally diverse populations. Therefore, this paper assessed the reliability and validity of an HIV/AIDS questionnaire that measures fours dimensions of HIV/AIDS awareness--factual knowledge, prejudice, personal risk,…
Controlling rotary desiccant wheels for dehumidification and cooling
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crooks, K.W.; Banks, N.J.
With greater focus on indoor air quality (IAQ) and ventilation, humidity control within spaces such as office buildings, hotels, schools, ice-skating rinks, nursing homes, and operating rooms has become paramount during the past decade. Control of relative humidity (RH) has been linked to increased comfort and the improved health of building occupants. The desiccant wheel process can be utilized in these applications to provide increased dehumidification while introducing minimal additional control parameters, often at lower cost.
Madureira, Joana; Mendes, Ana; Teixeira, João Paulo
2014-01-01
Workplace bans on smoking are interventions to reduce exposure to secondhand smoke (SHS) to try to prevent harmful health effects. The Portuguese Government on January 1, 2008, introduced the first national law banning smoking in public workplaces, including restaurants. The main aim of this study was to examine the impact of this law on indoor air quality (IAQ) in restaurants and on the respiratory and sensory health of restaurant workers. Concentrations of respirable suspended particulate matter (RSP), total volatile organic compounds (TVOC), carbon monoxide (CO), and carbon dioxide (CO2) in 10 restaurants were measured and compared before and after the ban. Benzene (C6H6) concentrations were also measured in all restaurants. Fifty-two and twenty-eight restaurant workers, respectively, answered questionnaires on exposure to SHS, and respiratory and sensory symptoms in the pre- and post-ban phases. There was a statistically significant decrease in RSP, CO, TVOC, and C6H6 concentrations after the ban. Additionally, in both phases the monitored CO2 concentrations greatly exceeded 1800 mg x m(-3), suggesting inefficient ventilation of the indoor spaces. Between pre- and post-ban phases a significant reduction in self-reported workplace SHS exposure was also observed after the enforcement of the law, as well as a significant marked reduction in dry, itching, irritated, or watery eyes, nasal problems, sore or dry throat, cough, wheeze, and headache. This study provides, in a single investigation, comparison of IAQ and respiratory health in Portugal before and after the introduction of the smoke-free law, the first data reported in the literature to our knowledge. Our findings suggest that a total workplace smoking ban results in a significant reduction in indoor air pollution and an improvement in the respiratory health of restaurant workers. These observations may have implications for policymakers and legislators currently considering the nature and extent of their smoke-free workplace legislation and could provide a useful contribution to the implementation of public health prevention programs.
Assessment of indoor air quality in office buildings across Europe - The OFFICAIR study.
Mandin, Corinne; Trantallidi, Marilena; Cattaneo, Andrea; Canha, Nuno; Mihucz, Victor G; Szigeti, Tamás; Mabilia, Rosanna; Perreca, Erica; Spinazzè, Andrea; Fossati, Serena; De Kluizenaar, Yvonne; Cornelissen, Eric; Sakellaris, Ioannis; Saraga, Dikaia; Hänninen, Otto; De Oliveira Fernandes, Eduardo; Ventura, Gabriela; Wolkoff, Peder; Carrer, Paolo; Bartzis, John
2017-02-01
The European project OFFICAIR aimed to broaden the existing knowledge regarding indoor air quality (IAQ) in modern office buildings, i.e., recently built or refurbished buildings. Thirty-seven office buildings participated in the summer campaign (2012), and thirty-five participated in the winter campaign (2012-2013). Four rooms were investigated per building. The target pollutants were twelve volatile organic compounds, seven aldehydes, ozone, nitrogen dioxide and particulate matter with aerodynamic diameter <2.5μm (PM 2.5 ). Compared to other studies in office buildings, the benzene, toluene, ethylbenzene, and xylene concentrations were lower in OFFICAIR buildings, while the α-pinene and d-limonene concentrations were higher, and the aldehyde, nitrogen dioxide and PM 2.5 concentrations were of the same order of magnitude. When comparing summer and winter, significantly higher concentrations were measured in summer for formaldehyde and ozone, and in winter for benzene, α-pinene, d-limonene, and nitrogen dioxide. The terpene and 2-ethylhexanol concentrations showed heterogeneity within buildings regardless of the season. Considering the average of the summer and winter concentrations, the acetaldehyde and hexanal concentrations tended to increase by 4-5% on average with every floor level increase, and the nitrogen dioxide concentration tended to decrease by 3% on average with every floor level increase. A preliminary evaluation of IAQ in terms of potential irritative and respiratory health effects was performed. The 5-day median and maximum indoor air concentrations of formaldehyde and ozone did not exceed their respective WHO air quality guidelines, and those of acrolein, α-pinene, and d-limonene were lower than their estimated thresholds for irritative and respiratory effects. PM 2.5 indoor concentrations were higher than the 24-h and annual WHO ambient air quality guidelines. Copyright © 2016 Elsevier B.V. All rights reserved.
Singer, B C; Delp, W W
2018-04-23
The ability to inexpensively monitor PM 2.5 to identify sources and enable controls would advance residential indoor air quality (IAQ) management. Consumer IAQ monitors incorporating low-cost optical particle sensors and connections with smart home platforms could provide this service if they reliably detect PM 2.5 in homes. In this study, particles from typical residential sources were generated in a 120 m 3 laboratory and time-concentration profiles were measured with 7 consumer monitors (2-3 units each), 2 research monitors (Thermo pDR-1500, MetOne BT-645), a Grimm Mini Wide-Range Aerosol Spectrometer (GRM), and a Tapered Element Oscillating Microbalance with Filter Dynamic Measurement System (FDMS), a Federal Equivalent Method for PM 2.5 . Sources included recreational combustion (candles, cigarettes, incense), cooking activities, an unfiltered ultrasonic humidifier, and dust. FDMS measurements, filter samples, and known densities were used to adjust the GRM to obtain time-resolved mass concentrations. Data from the research monitors and 4 of the consumer monitors-AirBeam, AirVisual, Foobot, Purple Air-were time correlated and within a factor of 2 of the estimated mass concentrations for most sources. All 7 of the consumer and both research monitors substantially under-reported or missed events for which the emitted mass was comprised of particles smaller than 0.3 μm diameter. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Particle loading rates for HVAC filters, heat exchangers, and ducts.
Waring, M S; Siegel, J A
2008-06-01
The rate at which airborne particulate matter deposits onto heating, ventilation, and air-conditioning (HVAC) components is important from both indoor air quality (IAQ) and energy perspectives. This modeling study predicts size-resolved particle mass loading rates for residential and commercial filters, heat exchangers (i.e. coils), and supply and return ducts. A parametric analysis evaluated the impact of different outdoor particle distributions, indoor emission sources, HVAC airflows, filtration efficiencies, coils, and duct system complexities. The median predicted residential and commercial loading rates were 2.97 and 130 g/m(2) month for the filter loading rates, 0.756 and 4.35 g/m(2) month for the coil loading rates, 0.0051 and 1.00 g/month for the supply duct loading rates, and 0.262 g/month for the commercial return duct loading rates. Loading rates are more dependent on outdoor particle distributions, indoor sources, HVAC operation strategy, and filtration than other considered parameters. The results presented herein, once validated, can be used to estimate filter changing and coil cleaning schedules, energy implications of filter and coil loading, and IAQ impacts associated with deposited particles. The results in this paper suggest important factors that lead to particle deposition on HVAC components in residential and commercial buildings. This knowledge informs the development and comparison of control strategies to limit particle deposition. The predicted mass loading rates allow for the assessment of pressure drop and indoor air quality consequences that result from particle mass loading onto HVAC system components.
Brown, Terry; Dassonville, Claire; Derbez, Mickael; Ramalho, Olivier; Kirchner, Severine; Crump, Derrick; Mandin, Corinne
2015-07-01
To date, few studies have analyzed the relationships between socioeconomic status (SES) and indoor air quality (IAQ). The aim of this study was to examine the relationships between socioeconomic and other factors and indoor air pollutant levels in French homes. The indoor air concentrations of thirty chemical, biological and physical parameters were measured over one week in a sample of 567 dwellings representative of the French housing stock between September 2003 and December 2005. Information on SES (household structure, educational attainment, income, and occupation), building characteristics, and occupants' habits and activities (smoking, cooking, cleaning, etc.) were collected through administered questionnaires. Separate stepwise linear regression models were fitted to log-transformed concentrations on SES and other factors. Logistic regression was performed on fungal contamination data. Households with lower income were more likely to have higher indoor concentrations of formaldehyde, but lower perchloroethylene indoor concentrations. Formaldehyde indoor concentrations were also associated with newly built buildings. Smoking was associated with increasing acetaldehyde and PM2.5 levels and the risk of a positive fungal contamination index. BTEX levels were also associated with occupant density and having an attached garage. The major predictors for fungal contamination were dampness and absolute humidity. These results, obtained from a large sample of dwellings, show for the first time in France the relationships between SES factors and indoor air pollutants, and believe they should be considered alongside occupant activities and building characteristics when study IAQ in homes. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.
Zuraimi, M S; Tham, K W; Chew, F T; Ooi, P L
2007-08-01
This paper reports the effects of ventilation strategies on indoor air quality (IAQ) and respiratory health of children within 104 child care centers (CCCs) in a hot and humid climate. The CCCs were categorized by ventilation strategies: natural (NV), air-conditioned and mechanically ventilated (ACMV), air-conditioned using split units (AC), and hybrid (NV and AC operated intermittently). The concentration levels of IAQ parameters in NV CCCs are characterized by the influence of the outdoors and good dilution of indoor pollutants. The lower ventilation rates in air-conditioned CCCs result in higher concentrations of occupant-related pollutants but lower outdoor pollutant ingress. This study also revealed lower prevalence for most asthma and allergy, and respiratory symptoms in children attending NV CCCs. In multivariate analyses controlled for the effects of confounders, the risk of current rhinitis among children is significantly higher if they attend mechanically ventilated CCCs compared to NV CCCs. Air-conditioned CCCs were also associated with higher adjusted prevalence ratio of severe phlegm and cough symptoms and lower respiratory illness. Finally, children attending CCCs with hybrid ventilation are at high risk for almost all the respiratory symptoms studied. This large field study indicates that different ventilation strategies employed by child care centers can cause significant variations in the indoor air quality and prevalence of asthma, allergies and respiratory symptoms of attending children. The higher prevalence rates of allergic and respiratory symptoms among young children, whose immune system is still under-developed, in child care centers, whether fully or partially air-conditioned, suggest that ventilation and plausible growth and propagation mechanisms of allergens and infectious agents be further investigated.
Syazwan, AI; Rafee, B Mohd; Juahir, Hafizan; Azman, AZF; Nizar, AM; Izwyn, Z; Syahidatussyakirah, K; Muhaimin, AA; Yunos, MA Syafiq; Anita, AR; Hanafiah, J Muhamad; Shaharuddin, MS; Ibthisham, A Mohd; Hasmadi, I Mohd; Azhar, MN Mohamad; Azizan, HS; Zulfadhli, I; Othman, J; Rozalini, M; Kamarul, FT
2012-01-01
Purpose To analyze and characterize a multidisciplinary, integrated indoor air quality checklist for evaluating the health risk of building occupants in a nonindustrial workplace setting. Design A cross-sectional study based on a participatory occupational health program conducted by the National Institute of Occupational Safety and Health (Malaysia) and Universiti Putra Malaysia. Method A modified version of the indoor environmental checklist published by the Department of Occupational Health and Safety, based on the literature and discussion with occupational health and safety professionals, was used in the evaluation process. Summated scores were given according to the cluster analysis and principal component analysis in the characterization of risk. Environmetric techniques was used to classify the risk of variables in the checklist. Identification of the possible source of item pollutants was also evaluated from a semiquantitative approach. Result Hierarchical agglomerative cluster analysis resulted in the grouping of factorial components into three clusters (high complaint, moderate-high complaint, moderate complaint), which were further analyzed by discriminant analysis. From this, 15 major variables that influence indoor air quality were determined. Principal component analysis of each cluster revealed that the main factors influencing the high complaint group were fungal-related problems, chemical indoor dispersion, detergent, renovation, thermal comfort, and location of fresh air intake. The moderate-high complaint group showed significant high loading on ventilation, air filters, and smoking-related activities. The moderate complaint group showed high loading on dampness, odor, and thermal comfort. Conclusion This semiquantitative assessment, which graded risk from low to high based on the intensity of the problem, shows promising and reliable results. It should be used as an important tool in the preliminary assessment of indoor air quality and as a categorizing method for further IAQ investigations and complaints procedures. PMID:23055779
Syazwan, Ai; Rafee, B Mohd; Juahir, Hafizan; Azman, Azf; Nizar, Am; Izwyn, Z; Syahidatussyakirah, K; Muhaimin, Aa; Yunos, Ma Syafiq; Anita, Ar; Hanafiah, J Muhamad; Shaharuddin, Ms; Ibthisham, A Mohd; Hasmadi, I Mohd; Azhar, Mn Mohamad; Azizan, Hs; Zulfadhli, I; Othman, J; Rozalini, M; Kamarul, Ft
2012-01-01
To analyze and characterize a multidisciplinary, integrated indoor air quality checklist for evaluating the health risk of building occupants in a nonindustrial workplace setting. A cross-sectional study based on a participatory occupational health program conducted by the National Institute of Occupational Safety and Health (Malaysia) and Universiti Putra Malaysia. A modified version of the indoor environmental checklist published by the Department of Occupational Health and Safety, based on the literature and discussion with occupational health and safety professionals, was used in the evaluation process. Summated scores were given according to the cluster analysis and principal component analysis in the characterization of risk. Environmetric techniques was used to classify the risk of variables in the checklist. Identification of the possible source of item pollutants was also evaluated from a semiquantitative approach. Hierarchical agglomerative cluster analysis resulted in the grouping of factorial components into three clusters (high complaint, moderate-high complaint, moderate complaint), which were further analyzed by discriminant analysis. From this, 15 major variables that influence indoor air quality were determined. Principal component analysis of each cluster revealed that the main factors influencing the high complaint group were fungal-related problems, chemical indoor dispersion, detergent, renovation, thermal comfort, and location of fresh air intake. The moderate-high complaint group showed significant high loading on ventilation, air filters, and smoking-related activities. The moderate complaint group showed high loading on dampness, odor, and thermal comfort. This semiquantitative assessment, which graded risk from low to high based on the intensity of the problem, shows promising and reliable results. It should be used as an important tool in the preliminary assessment of indoor air quality and as a categorizing method for further IAQ investigations and complaints procedures.
Singh, Deepak; Kumar, Amit; Kumar, Krishan; Singh, Bupender; Mina, Usha; Singh, Braj Bihari; Jain, Vinod Kumar
2016-12-01
Indoor Air Quality (IAQ) is considered to be of great concern due to its adverse impact on the human health nowadays. The presence of different air pollutants along with noise may aggravate the IAQ. The present study attempts to examine IAQ in terms of major criteria air pollutants (O 3 , NOx=NO+NO 2 , CO and PM 2.5 ) along with total volatile organic compound (TVOC), individual VOC and noise pollution in indoor and outdoor environment of a Commercial Shopping Complex (CSC) in Delhi. Real time measurements have been carried out for O 3 , NOx, CO, PM 2.5 , TVOC and noise while thirteen individual VOCs have been estimated using NIOSH method was performed using Gas Chromatograph. The study also aimed to find out the relationship among VOCs, source estimation using Principal Component Analysis. The observed results for the targeted pollutants were also compared with international and national recommended permissible values. The mean values of O 3 , NOx, CO, PM 2.5 and TVOC are found to be 17.6/(15.0) ppb, 15.8/(14.1) ppb, 8.4/(1.9) ppm, 125.4/(74.6) μg/m 3 and 412.5/(226.5) μg/m 3 for indoor/(outdoor), respectively. Among the individual VOC, toluene was the most abundant followed by xylene-isomers and benzene. The noise pollution level in Indoor/outdoor were found to be 51.5/46.4dB which is below the guideline value (65dB) provided by the WHO. Most of the pollutants were found to have indoor sources. The different kinds of pollutants and noise may have synergistic effect and aggravate the health of the people working and visiting the CSC. Copyright © 2016 Elsevier B.V. All rights reserved.
Shaughnessy, R J; Haverinen-Shaughnessy, U; Nevalainen, A; Moschandreas, D
2006-12-01
Poor conditions leading to substandard indoor air quality (IAQ) in classrooms have been frequently cited in the literature over the past two decades. However, there is limited data linking poor IAQ in the classrooms to student performance. Whereas, it is assumed that poor IAQ results in reduced attendance and learning potential, and subsequent poor student performance, validating this hypothesis presents a challenge in today's school environment. This study explores the association between student performance on standardized aptitude tests that are administered to students on a yearly basis, to classroom carbon dioxide (CO2) concentrations, which provide a surrogate of ventilation being provided to each room. Data on classroom CO2 concentrations (over a 4-5 h time span within a typical school day) were recorded in fifth grade classrooms in 54 elementary schools within a school district in the USA. Results from this preliminary study yield a significant (P < 0.10) association between classroom-level ventilation rate and test results in math. They also indicate that non-linear effects may need to be considered for better representation of the association. A larger sample size is required in order to draw more definitive conclusions. Practical Implications Future studies could focus on (1) gathering more evidence on the possible association between classroom ventilation rates and students' academic performance; (2) the linear/non-linear nature of the association; and (3) whether it is possible to detect 'no observed adverse effect level' for adequate ventilation with respect to academic performance in schools. All of this information could be used to improve guidance and take regulatory actions to ensure adequate ventilation in schools. The high prevalence of low ventilation rates, combined with the growing evidence of the positive impact that sufficient ventilation has on human performance, suggests an opportunity for improving design and management of school facilities.
Batterman, S; Du, L; Mentz, G; Mukherjee, B; Parker, E; Godwin, C; Chin, J-Y; O'Toole, A; Robins, T; Rowe, Z; Lewis, T
2012-06-01
This study, a randomized controlled trial, evaluated the effectiveness of free-standing air filters and window air conditioners (ACs) in 126 low-income households of children with asthma. Households were randomized into a control group, a group receiving a free-standing HEPA filter placed in the child's sleeping area, and a group receiving the filter and a window-mounted AC. Indoor air quality (IAQ) was monitored for week-long periods over three to four seasons. High concentrations of particulate matter (PM) and carbon dioxide were frequently seen. When IAQ was monitored, filters reduced PM levels in the child's bedroom by an average of 50%. Filter use varied greatly among households and declined over time, for example, during weeks when pollutants were monitored, filter use was initially high, averaging 84±27%, but dropped to 63±33% in subsequent seasons. In months when households were not visited, use averaged only 34±30%. Filter effectiveness did not vary in homes with central or room ACs. The study shows that measurements over multiple seasons are needed to characterize air quality and filter performance. The effectiveness of interventions using free-standing air filters depends on occupant behavior, and strategies to ensure filter use should be an integral part of interventions. Environmental tobacco smoke (ETS) increased particulate matter (PM) levels by about 14 μg/m3 and was often detected using ETS-specific tracers despite restrictions on smoking in the house as reported on questionnaires administered to caregivers. PM concentrations depended on season, filter usage, relative humidity, air exchange ratios, number of children, outdoor PM levels, sweeping/dusting, and presence of a central air conditioner (AC). Free-standing air filters can be an effective intervention that provides substantial reductions in PM concentrations if the filters are used. However, filter use was variable across the study population and declined over the study duration, and thus strategies are needed to encourage and maintain use of filters. The variability in filter use suggests that exposure misclassification is a potential problem in intervention studies using filters. The installation of a room AC in the bedroom, intended to limit air exchange ratios, along with an air filter, did not lower PM levels more than the filter alone. © 2011 John Wiley & Sons A/S.
Indoor air quality in hairdressing salons in Taipei.
Chang, C-J; Cheng, S-F; Chang, P-T; Tsai, S-W
2018-01-01
To improve indoor air quality and to protect public health, Taiwan has enacted the "Indoor Air Quality Act (IAQ Act)" in 2012. For the general public, the indoor air quality in hair salons is important because it is a popular location that people will often visit for hair treatments. However, only a few exposure assessments regarding air pollutants have previously been performed in hair salons. To assess the air quality of hairdressing environments in Taipei, ten hairdressing salons were included for a walk-through survey in this study. In addition, the airborne concentrations of formaldehyde, volatile organic compounds (VOCs), CO 2 , and phthalate esters were also determined in 5 salons. Charcoal, XAD-2, and OVS-Tenax tubes were used for the air sampling, while the samples were analyzed with gas chromatography/mass spectrometer. It was found that the products used in hair salons contained various chemicals. In fact, from the walk-through survey, a total of 387 different ingredients were found on 129 hair product labels. The hair salons were not well ventilated, with CO 2 levels of 600 to 3576 ppm. The formaldehyde concentrations determined in this study ranged from 12.40 to 1.04 × 10 3 μg m -3 , and the maximum level was above the permissible exposure limit (PEL) of US Occupational Safety and Health Administration (US OSHA). Additionally, 83% of the samples were with levels higher than the standard regulated by Taiwan's IAQ Act. The concentrations of VOCs and phthalate esters were below the occupational exposure limits (OELs), but higher than what was found in general residential environments. The hair products were considered as the major source of air pollutants because significantly higher concentrations were found around the working areas. The number of perming treatments, the number of workers, and the frequency of using formaldehyde releasing products, were found to be associated with the levels of formaldehyde. This study indicates that efforts are needed to improve the indoor air quality in hairdressing salons in Taipei. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fisk, William J.; Destaillats, H.; Apte, M.G.
Heating, ventilating, and cooling classrooms in California consume substantial electrical energy. Indoor air quality (IAQ) in classrooms affects studenthealth and performance. In addition to airborne pollutants that are emitted directly by indoor sources and those generated outdoors, secondary pollutants can be formed indoors by chemical reaction of ozone with other chemicals and materials. Filters are used in nearly all classroom heating, ventilation and air?conditioning (HVAC) systems to maintain energy-efficient HVAC performance and improve indoor air quality; however, recent evidence indicates that ozone reactions with filters may, in fact, be a source of secondary pollutants. This project quantitatively evaluated ozone depositionmore » in HVAC filters and byproduct formation, and provided a preliminary assessment of the extent towhich filter systems are degrading indoor air quality. The preliminary information obtained will contribute to the design of subsequent research efforts and the identification of energy efficient solutions that improve indoor air quality in classrooms and the health and performance of students.« less
Temporal variation of indoor air quality in an enclosed swine confinement building.
O'Shaughnessy, P T; Achutan, C; Karsten, A W
2002-11-01
Human health hazards can exist in swine confinement buildings due to poor indoor air quality (IAQ). During this study, airborne dust and ammonia concentrations were monitored within a working farrowing facility as indicators of IAQ. The purposes of this study were to assess the temporal variability of the airborne dust and ammonia levels over both a daily and seasonal basis, and to determine the accuracy of real-time sensors relative to actively sampled data. An ammonia sensor, aerosol photometer, indoor relative humidity sensor, and datalogger containing an indoor temperature sensor were mounted on a board 180 cm above the floor in the center of a room in the facility. Sensor readings were taken once every 4 minutes during animal occupancy (3-week intervals). Measurements of total and respirable dust concentrations by standard method, aerosol size distribution, and ammonia concentrations were taken once per week, in addition to temperature and relative humidity measurements using a thermometer and sling psychrometer, respectively. Samples were taken between September 1999 and August 2000. Diurnal variations in airborne dust revealed an inverse relationship with changes in indoor temperature and, by association, changes in airflow rate. Ammonia levels changed despite relatively stable internal temperatures. This change may be related to both changes in flow rates and in volatility rates. As expected, contaminant concentrations increased during the cold weather months, but these differences were not significantly different from other seasons. However, total dust concentrations were very low (geometric mean = 0.8 mg/m3) throughout the year. Likewise, ammonia concentrations averaged only 3.6 ppm in the well-maintained study site.
Choo, Chua Poh; Jalaludin, Juliana
2015-01-01
The indoor environment is a major source of human exposure to pollutants. Some pollutants can have concentrations that are several times higher indoors than outdoors. Prolonged exposure may lead to adverse biologic effects, even at low concentrations. Several studies done in Malaysia had underlined the role of indoor air pollution in affecting respiratory health, especially for school-aged children. A critical review was conducted on the quantitative literature linking indoor air pollution with respiratory illnesses among school-aged children. This paper reviews evidence of the association between indoor air quality (IAQ) and its implications on respiratory health among Malaysian school-aged children. This review summarizes six relevant studies conducted in Malaysia for the past 10 years. Previous epidemiologic studies relevant to indoor air pollutants and their implications on school-aged children's respiratory health were obtained from electronic database and included as a reference in this review. The existing reviewed data emphasize the impact of IAQ parameters, namely, indoor temperature, ventilation rates, indoor concentration of carbon dioxide (CO2), carbon monoxide (CO), particulate matters (PM), volatile organic compounds (VOCs), nitrogen dioxide (NO2) and airborne microbes, on children's respiratory health. The study found that most of the Malaysian school-aged children are exposed to the inadequate environment during their times spent either in their houses or in their classrooms, which is not in compliance with the established standards. Children living in households or studying in schools in urban areas are more likely to suffer from respiratory illnesses compared with children living in homes or studying in schools in rural areas.
Sakamoto, Hironari; Uchiyama, Shigehisa; Kihara, Akiko; Tsutake, Toyoshige; Bekki, Kanae; Inaba, Yohei; Nakagome, Hideki; Kunugita, Naoki
2015-01-01
Indoor air quality (IAQ) is a major concern, because people on average spend the vast majority of their time indoors and they are repeatedly exposed to indoor air pollutants. In this study, to assess indoor air quality in Chiba City, gaseous chemical compounds were surveyed using four types of diffusive sampler. Gaseous chemical compounds such as carbonyls, volatile organic compounds (VOC), acid gases, basic gases, and ozone were measured in indoor and outdoor air of 50 houses throughout Chiba City in winter and summer. Four types of diffusive sampler were used in this study: DSD-BPE/DNPH packed with 2,4-dinitrophenyl hydrazine and trans-1,2-bis(2-pyridyl)ethylene-coated silica for ozone and carbonyls; VOC-SD packed with Carboxen 564 particles for volatile organic compounds; DSD-TEA packed with triethanolamine-impregnated silica for acid gases; and DSD-NH3 packed with phosphoric acid-impregnated silica for basic gases. Almost all compounds in indoor air were detected at higher concentrations in summer than in winter. However, the nitrogen dioxide concentration in indoor air particularly increased only in winter, which well correlated with the formic acid concentration (correlation coefficient=0.974). The compound with the highest concentrations in indoor air was p-dichlorobenzene, with recorded levels of 13,000 μg m(-3) in summer and 1,100 μg m(-3) in winter in indoor air. p-Dichlorobenzene in summer and nitrogen dioxide in winter are detected at markedly high concentrations. Pollution control and continuous monitoring of IAQ are indispensable for human health.
Amodio, M; Dambruoso, P R; de Gennaro, Gianluigi; de Gennaro, L; Loiotile, A Demarinis; Marzocca, A; Stasi, F; Trizio, L; Tutino, M
2014-12-01
In order to assess indoor air quality (IAQ), two 1-week monitoring campaigns of volatile organic compounds (VOC) were performed in different areas of a multistorey shopping mall. High-spatial-resolution monitoring was conducted at 32 indoor sites located in two storehouses and in different departments of a supermarket. At the same time, VOC concentrations were monitored in the mall and parking lot area as well as outdoors. VOC were sampled at 48-h periods using diffusive samplers suitable for thermal desorption. The samples were then analyzed with gas chromatography-mass spectrometry (GC-MS). The data analysis and chromatic maps indicated that the two storehouses had the highest VOC concentrations consisting principally of terpenes. These higher TVOC concentrations could be a result of the low efficiency of the air exchange and intake systems, as well as the large quantity of articles stored in these small spaces. Instead, inside the supermarket, the food department was the most critical area for VOC concentrations. To identify potential emission sources in this department, a continuous VOC analyzer was used. The findings indicated that the highest total VOC concentrations were present during cleaning activities and that these activities were carried out frequently in the food department. The study highlights the importance of conducting both high-spatial-resolution monitoring and high-temporal-resolution monitoring. The former was able to identify critical issues in environments with a complex emission scenario while the latter was useful in interpreting the dynamics of each emission source.
Children's Health and Indoor Air Quality in Primary Schools and Homes in Portugal-Study Design.
Madureira, Joana; Paciência, Inês; Ramos, Elisabete; Barros, Henrique; Pereira, Cristiana; Teixeira, João Paulo; Fernandes, Eduardo de Oliveira
2015-01-01
The main aim of the research project "On the Contribution of Schools to Children's Overall Indoor Air Exposure" is to study associations between adverse health effects, namely, allergy, asthma, and respiratory symptoms, and indoor air pollutants to which children are exposed to in primary schools and homes. Specifically, this investigation reports on the design of the study and methods used for data collection within the research project and discusses factors that need to be considered when designing such a study. Further, preliminary findings concerning descriptors of selected characteristics in schools and homes, the study population, and clinical examination are presented. The research project was designed in two phases. In the first phase, 20 public primary schools were selected and a detailed inspection and indoor air quality (IAQ) measurements including volatile organic compounds (VOC), aldehydes, particulate matter (PM2.5, PM10), carbon dioxide (CO2), carbon monoxide (CO), bacteria, fungi, temperature, and relative humidity were conducted. A questionnaire survey of 1600 children of ages 8-9 years was undertaken and a lung function test, exhaled nitric oxide (eNO), and tear film stability testing were performed. The questionnaire focused on children's health and on the environment in their school and homes. One thousand and ninety-nine questionnaires were returned. In the second phase, a subsample of 68 children was enrolled for further studies, including a walk-through inspection and checklist and an extensive set of IAQ measurements in their homes. The acquired data are relevant to assess children's environmental exposures and health status.
Dols, W Stuart; Emmerich, Steven J; Polidoro, Brian J
2016-08-01
Building modelers need simulation tools capable of simultaneously considering building energy use, airflow and indoor air quality (IAQ) to design and evaluate the ability of buildings and their systems to meet today's demanding energy efficiency and IAQ performance requirements. CONTAM is a widely-used multizone building airflow and contaminant transport simulation tool that requires indoor temperatures as input values. EnergyPlus is a prominent whole-building energy simulation program capable of performing heat transfer calculations that require interzone and infiltration airflows as input values. On their own, each tool is limited in its ability to account for thermal processes upon which building airflow may be significantly dependent and vice versa. This paper describes the initial phase of coupling of CONTAM with EnergyPlus to capture the interdependencies between airflow and heat transfer using co-simulation that allows for sharing of data between independently executing simulation tools. The coupling is accomplished based on the Functional Mock-up Interface (FMI) for Co-simulation specification that provides for integration between independently developed tools. A three-zone combined heat transfer/airflow analytical BESTEST case was simulated to verify the co-simulation is functioning as expected, and an investigation of a two-zone, natural ventilation case designed to challenge the coupled thermal/airflow solution methods was performed.
Indoor air condensate as a novel matrix for monitoring inhalable organic contaminants.
Roll, Isaac B; Halden, Rolf U; Pycke, Benny F G
2015-05-15
With the population of developed nations spending nearly 90% of their time indoors, indoor air quality (IAQ) is a critical indicator of human health risks from inhalation of airborne contaminants. We present a novel approach for qualitative monitoring of IAQ through the collection and analysis of indoor air condensate discharged from heat exchangers of heating, ventilation, and air conditioning (HVAC) systems. Condensate samples were collected from six suburban homes and one business in Maricopa County, Arizona, concentrated via solid-phase extraction, analyzed for 10 endocrine disrupting chemicals (EDCs) by liquid chromatography-tandem mass spectrometry (LC-MS/MS), and screened for additional organic compounds by gas chromatography-mass spectrometry (GC-MS). All 10 EDCs were detected in at least one of the sampled buildings. More than 100 additional compounds were detected by GC-MS, of which 40 were tentatively identified using spectral database searches. Twelve compounds listed as designated chemicals for biomonitoring by the California Environmental Contaminant Biomonitoring Program were detected. Microfiltration of condensate samples prior to extraction had no discernable effect on contaminant concentration, suggesting that contaminants were freely dissolved or associated with inhalable, submicron particles. This study is the first to document the utility of HVAC condensate for the qualitative assessment of indoor air for pollutants. Copyright © 2015 Elsevier B.V. All rights reserved.
Giardino, N J
1997-03-01
In military courts of law, the good soldier defense is often used by the defendant to explain the presence of 11-nor-delta-9-tetrahydrocannabinol-9-carboxylic acid in urine (hereafter referred to as THCA) above the Department of Defense (DOD) established limit of 15 ng/mL. The defense will contend the defendant unwittingly breathed side-stream marijuana smoke, thus resulting in the presence of THCA in the defendant's urine. The purpose of this work was to link an indoor air quality model (IAQ) with a pharmacokinetic (PK) model to predict a passive marijuana smoker's resultant concentration of the major urinary metabolite THCA.
Park, Jae Hong; Peters, Thomas M.; Altmaier, Ralph; Jones, Samuel M.; Gassman, Richard; Anthony, T. Renée
2017-01-01
We have developed a time-dependent simulation model to estimate in-room concentrations of multiple contaminants [ammonia (NH3), carbon dioxide (CO2), carbon monoxide (CO) and dust] as a function of increased ventilation with filtered recirculation for swine farrowing facilities. Energy and mass balance equations were used to simulate the indoor air quality (IAQ) and operational cost for a variety of ventilation conditions over a 3-month winter period for a facility located in the Midwest U.S., using simplified and real-time production parameters, comparing results to field data. A revised model was improved by minimizing the sum of squared errors (SSE) between modeled and measured NH3 and CO2. After optimizing NH3 and CO2, other IAQ results from the simulation were compared to field measurements using linear regression. For NH3, the coefficient of determination (R2) for simulation results and field measurements improved from 0.02 with the original model to 0.37 with the new model. For CO2, the R2 for simulation results and field measurements was 0.49 with the new model. When the makeup air was matched to hallway air CO2 concentrations (1,500 ppm), simulation results showed the smallest SSE. With the new model, the R2 for other contaminants were 0.34 for inhalable dust, 0.36 for respirable dust, and 0.26 for CO. Operation of the air cleaner decreased inhalable dust by 35% and respirable dust concentrations by 33%, while having no effect on NH3, CO2, in agreement with field data, and increasing operational cost by $860 (58%) for the three-month period. PMID:28775911
NASA Astrophysics Data System (ADS)
Stout, D. M.; Mason, M. A.
A study was conducted in the US EPA Indoor Air Quality (IAQ) Research House to determine the spatial and temporal distribution of chlorpyrifos following a professional crack and crevice application in the kitchen. Following the application, measurements were made in the kitchen, den and master bedroom over 21 days. Airborne concentrations were collected using both polyurethane foam (PUF) and the OSHA versatile sampler composed of XAD and PUF media located in tandem. Measured airborne concentrations were similar for the two samplers and were higher in the three rooms following the application. The highest measured concentrations were reached during the initial 24-h following application; concentrations subsequently declined over the 21-day study period to levels slightly above background. Spatial and temporal distributions onto surfaces were measured using 10-cm 2 rayon deposition coupons located on the floor. Sections were cut from existing carpet to determine the total extractable residues. Chlorpyrifos was measured from all matrixes in the kitchen, den and bedroom and the data shows the transport of airborne residues from the point of application to remote locations in the house. The findings are compared and discussed relative to another study conducted in which total release aerosols containing chlorpyrifos were activated in the IAQ research house and the resulting distributions evaluated. For both studies dose estimates were constructed for the exposure pathways using the Stochastic Human Exposure and Dose Estimation Model for pesticides. The United States Environmental Protection Agency has been mandated to examine children's exposure to environmental pollutants such as pesticides. This research specifically reduces uncertainties associated with estimating children's potential exposures to residentially applied pesticides and provides inputs to further evaluate and validate residential exposure models which might be used to reduce exposures and perform risk assessments.
Optimization of Ventilation Energy Demands and Indoor Air Quality in High-Performance Homes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hun, Diana E; Jackson, Mark C; Shrestha, Som S
2014-01-01
High-performance homes require that ventilation energy demands and indoor air quality (IAQ) be simultaneously optimized. We attempted to bridge these two areas by conducting tests in a research house located in Oak Ridge, TN, that was 20 months old, energy-efficient (i.e., expected to consume 50% less energy than a house built per the 2006 IRC), tightly-built (i.e., natural ventilation rate ~0.02 h-1), unoccupied, and unfurnished. We identified air pollutants of concern in the test home that could generally serve as indicators of IAQ, and conduced field experiments and computer simulations to determine the effectiveness and energy required by various techniquesmore » that lessened the concentration of these contaminants. Formaldehyde was selected as the main pollutant of concern among the contaminants that were sampled in the initial survey because it was the only compound that showed concentrations that were greater than the recommended exposure levels. Field data indicate that concentrations were higher during the summer primarily because emissions from sources rise with increases in temperature. Furthermore, supply ventilation and gas-phase filtration were effective means to reduce formaldehyde concentrations; however, exhaust ventilation had minimal influence on this pollutant. Results from simulations suggest that formaldehyde concentrations obtained while ventilating per ASHRAE 62.2-2010 could be decreased by about 20% from May through September through three strategies: 1) increasing ASHRAE supply ventilation by a factor of two, 2) reducing the thermostat setpoint from 76 to 74 F, or 3) running a gas-phase filtration system while decreasing supply ventilation per ASHRAE by half. In the mixed-humid climate of Oak Ridge, these strategies caused increases in electricity cost of ~$5 to ~$15/month depending on outdoor conditions.« less
Evaluation of the Impact of Indoor Smoking Bans on Air Quality in Australian Licensed Clubs
NASA Astrophysics Data System (ADS)
Davidson, Margaret Elissa
The quality of indoor air in Australian buildings is unknown due to limited published data. The assessment of indoor air quality (IAQ) in hospitality environments is of special concern because they are frequented by sensitive populations such as the elderly, children, and people with pre-existing health conditions, who may be at risk of developing adverse health reactions if the IAQ is poor. As of 2010, all Australian states and territories have introduced legalisation banning smoking in enclosed public places, including licensed clubs. This project has evaluated the impact of indoor smoking bans on air quality inside and outside of Australian licensed clubs. In doing this it has identified emerging IAQ issues in post smoking ban environments, and documented the airborne concentrations of previously unstudied air contaminants such as particulate matter with a 50% cut-point diameter of 1.0 ?m (PM1.0) and particulate polycyclic aromatic hydrocarbons (PPAH) in the indoor smoking areas of Australian licensed clubs. The study involved collecting approximately 400 hours of air quality data, of which 200 hours was collected before bans and 200 hrs was collected after smoking bans were introduced in licensed clubs located within two local government districts of South Eastern Australia. Clubs 1 to 7 were located in the one district and Clubs 8 to 11 in the other district. Club 4 dropped out following the pre ban monitoring, and the results were omitted from analysis. The air quality parameters measured inside include particulate matter with a 50% cut-point diameter of 2.5 mum (PM2.5), PPAH, carbon monoxide (CO), carbon dioxide mu(CO2), temperature and humidity. The air quality parameters measured outside were PM2.5, CO2, temperature and humidity. Each of the parameters were monitored for 4 hour periods on 4 occasions in each club both before, and after the introduction of indoor smoking bans. Additional monitoring of indoor concentrations of PM1.0, nicotine and PM2.5 particulates with a special calibration factor for environmental tobacco smoke calibration factor of 0.32 (PM2.5 (0.32)) was undertaken in the second group of clubs and monthly monitoring following the bans was undertaken in Clubs 9 and 11. There was a significant reduction in the mean airborne concentrations of PM2.5, PM1.0, PM2.5 (0.32), PPAH, CO and nicotine at all clubs following the implementation of the smoking bans. Of note was the increase in the mean outdoor PM2.5 concentrations at 6 clubs, and the significant increase in the number of outdoor smokers at 8 venues. The greatest change was an increase in the frequency of outdoor PM2.5 concentrations exceeding 25 mum m-3 which is the Australian PM2.5 advisory standard for ambient air (24 hours). Weak to strong significant correlations (R2=0.402-0.757 p=0.000-0.022) were identified between outdoor smokers and indoor PM2.5 concentrations (3 clubs), and a significant correlation (R2=1.000 p=0.000) between nicotine and indoor pollutants at one club. The results of this study indicate that indoor smoking bans may not fully protect the health of the public and workers in venues because of the possible infiltration of environmental tobacco smoke (ETS) identified at three clubs, as well as outdoor exposure to ETS associated with an increase in smoking activity. The lack of current indoor air quality standards makes the interpretation of the post ban air quality data difficult. Although, the mean concentration of contaminants were all below recommended limits for ambient air. The potential infiltration of ETS inside some clubs indicates that air quality may still represent both an occupational and public health risk because ETS has no safe exposure limit (WHO, 2000). (Abstract shortened by ProQuest.).
Angelon-Gaetz, K.A.; Richardson, D.B.; Lipton, D.M.; Marshall, S.W.; Lamb, B.; LoFrese, T.
2014-01-01
Both high and low indoor relative humidity (RH) directly impact indoor air quality (IAQ), an important school health concern. Prior school studies reported a high prevalence of mold, roaches, and water damage; however, few examined associations between modifiable classroom factors and RH, a quantitative indicator of dampness. We recorded RH longitudinally in 134 North Carolina classrooms (n= 9066 classroom-days) to quantify the relationships between modifiable classroom factors and average daily RH below, within, or above levels recommended to improve school IAQ (30–50% or 30–60% RH). The odds of having high RH (>60%) were 5.8 (95% Confidence Interval (CI): 2.9, 11.3) times higher in classrooms with annual compared to quarterly heating, ventilating, and air conditioning (HVAC) system maintenance, and 2.5 (95% CI: 1.5, 4.2) times higher in classrooms with HVAC economizers compared to those without economizers. Classrooms with direct expansion split systems compared to chilled water systems had 2.7 (95% CI: 1.7, 4.4) times higher odds of low RH (<30%). When unoccupied, classrooms with thermostat setbacks had 3.7 (95% CI: 1.7, 8.3) times the odds of high RH (>60%) of those without setbacks. This research suggests actionable decision points for school design and maintenance to prevent high or low classroom RH. PMID:25515546
Kwon, Soon-Bark; Jeong, Wootae; Park, Duckshin; Kim, Ki-Tae; Cho, Kyung Hwa
2015-10-30
Given that around eight million commuters use the Seoul Metropolitan Subway (SMS) each day, the indoor air quality (IAQ) of its stations has attracted much public attention. We have monitored the concentration of particulate matters (PMx) (i.e., PM10, PM2.5, and PM1) in six major transfer stations per minute for three weeks during the summer, autumn, and winter in 2014 and 2015. The data were analyzed to investigate the relationship between PMx concentration and multivariate environmental factors using statistical methods. The average PM concentration observed was approximately two or three times higher than outdoor PM10 concentration, showing similar temporal patterns at concourses and platforms. This implies that outdoor PM10 is the most significant factor in controlling indoor PM concentration. In addition, the station depth and number of trains passing through stations were found to be additional influences on PMx. Principal component analysis (PCA) and self-organizing map (SOM) were employed, through which we found that the number of trains influences PM concentration in the vicinity of platforms only, and PMx hotspots were determined. This study identifies the external and internal factors affecting PMx characteristics in six SMS stations, which can assist in the development of effective IAQ management plans to improve public health. Copyright © 2015 Elsevier B.V. All rights reserved.
PM2.5 in Urban and Rural Nursery Schools in Upper Silesia, Poland: Trace Elements Analysis.
Mainka, Anna; Zajusz-Zubek, Elwira; Kaczmarek, Konrad
2015-07-14
Indoor air quality (IAQ) in nursery schools is an emerging public health challenge. Particular attention should be paid to younger children, because they are more vulnerable to air pollution than older children. Among air pollutants, fine particulate matter (PM2.5) is of the greatest interest mainly due to its strong association with acute and chronic effects on children's health. In this paper, we present concentrations of PM2.5 and the composition of its trace elements at naturally ventilated nursery schools located in the area of Gliwice, Poland. The nursery schools were selected to characterize areas with different degrees of urbanization and traffic densities during the winter and spring seasons. The results indicate there is a problem with elevated concentrations of PM2.5 inside the examined classrooms. The children's exposure to trace elements was different based on localization and season. PM2.5 concentration and its trace element composition have been studied using correlation coefficients between the different trace elements, the enrichment factor (EF) and principal component analysis (PCA). PCA allowed the identification of the three components: anthropogenic and geogenic sources (37.2%), soil dust contaminated by sewage sludge dumping (18.6%) and vehicular emissions (19.5%).
Dols, W Stuart; Emmerich, Steven J; Polidoro, Brian J
2016-03-01
Building energy analysis tools are available in many forms that provide the ability to address a broad spectrum of energy-related issues in various combinations. Often these tools operate in isolation from one another, making it difficult to evaluate the interactions between related phenomena and interacting systems, forcing oversimplified assumptions to be made about various phenomena that could otherwise be addressed directly with another tool. One example of such interdependence is the interaction between heat transfer, inter-zone airflow and indoor contaminant transport. In order to better address these interdependencies, the National Institute of Standards and Technology (NIST) has developed an updated version of the multi-zone airflow and contaminant transport modelling tool, CONTAM, along with a set of utilities to enable coupling of the full CONTAM model with the TRNSYS simulation tool in a more seamless manner and with additional capabilities that were previously not available. This paper provides an overview of these new capabilities and applies them to simulating a medium-size office building. These simulations address the interaction between whole-building energy, airflow and contaminant transport in evaluating various ventilation strategies including natural and demand-controlled ventilation. CONTAM has been in practical use for many years allowing building designers, as well as IAQ and ventilation system analysts, to simulate the complex interactions between building physical layout and HVAC system configuration in determining building airflow and contaminant transport. It has been widely used to design and analyse smoke management systems and evaluate building performance in response to chemical, biological and radiological events. While CONTAM has been used to address design and performance of buildings implementing energy conserving ventilation systems, e.g., natural and hybrid, this new coupled simulation capability will enable users to apply the tool to couple CONTAM with existing energy analysis software to address the interaction between indoor air quality considerations and energy conservation measures in building design and analysis. This paper presents two practical case studies using the coupled modelling tool to evaluate IAQ performance of a CO 2 -based demand-controlled ventilation system under different levels of building envelope airtightness and the design and analysis of a natural ventilation system.
Dols, W. Stuart.; Emmerich, Steven J.; Polidoro, Brian J.
2016-01-01
Building energy analysis tools are available in many forms that provide the ability to address a broad spectrum of energy-related issues in various combinations. Often these tools operate in isolation from one another, making it difficult to evaluate the interactions between related phenomena and interacting systems, forcing oversimplified assumptions to be made about various phenomena that could otherwise be addressed directly with another tool. One example of such interdependence is the interaction between heat transfer, inter-zone airflow and indoor contaminant transport. In order to better address these interdependencies, the National Institute of Standards and Technology (NIST) has developed an updated version of the multi-zone airflow and contaminant transport modelling tool, CONTAM, along with a set of utilities to enable coupling of the full CONTAM model with the TRNSYS simulation tool in a more seamless manner and with additional capabilities that were previously not available. This paper provides an overview of these new capabilities and applies them to simulating a medium-size office building. These simulations address the interaction between whole-building energy, airflow and contaminant transport in evaluating various ventilation strategies including natural and demand-controlled ventilation. Practical Application CONTAM has been in practical use for many years allowing building designers, as well as IAQ and ventilation system analysts, to simulate the complex interactions between building physical layout and HVAC system configuration in determining building airflow and contaminant transport. It has been widely used to design and analyse smoke management systems and evaluate building performance in response to chemical, biological and radiological events. While CONTAM has been used to address design and performance of buildings implementing energy conserving ventilation systems, e.g., natural and hybrid, this new coupled simulation capability will enable users to apply the tool to couple CONTAM with existing energy analysis software to address the interaction between indoor air quality considerations and energy conservation measures in building design and analysis. This paper presents two practical case studies using the coupled modelling tool to evaluate IAQ performance of a CO2-based demand-controlled ventilation system under different levels of building envelope airtightness and the design and analysis of a natural ventilation system. PMID:27099405
Risk in cleaning: chemical and physical exposure.
Wolkoff, P; Schneider, T; Kildesø, J; Degerth, R; Jaroszewski, M; Schunk, H
1998-04-23
Cleaning is a large enterprise involving a large fraction of the workforce worldwide. A broad spectrum of cleaning agents has been developed to facilitate dust and dirt removal, for disinfection and surface maintenance. The cleaning agents are used in large quantities throughout the world. Although a complex pattern of exposure to cleaning agents and resulting health problems, such as allergies and asthma, are reported among cleaners, only a few surveys of this type of product have been performed. This paper gives a broad introduction to cleaning agents and the impact of cleaning on cleaners, occupants of indoor environments, and the quality of cleaning. Cleaning agents are usually grouped into different product categories according to their technical functions and the purpose of their use (e.g. disinfectants and surface care products). The paper also indicates the adverse health and comfort effects associated with the use of these agents in connection with the cleaning process. The paper identifies disinfectants as the most hazardous group of cleaning agents. Cleaning agents contain evaporative and non-evaporative substances. The major toxicologically significant constituents of the former are volatile organic compounds (VOCs), defined as substances with boiling points in the range of 0 degree C to about 400 degrees C. Although laboratory emission testing has shown many VOCs with quite different time-concentration profiles, few field studies have been carried out measuring the exposure of cleaners. However, both field studies and emission testing indicate that the use of cleaning agents results in a temporal increase in the overall VOC level. This increase may occur during the cleaning process and thus it can enhance the probability of increased short-term exposure of the cleaners. However, the increased levels can also be present after the cleaning and result in an overall increased VOC level that can possibly affect the indoor air quality (IAQ) perceived by occupants. The variety and duration of the emissions depend inter alia on the use of fragrances and high boiling VOCs. Some building materials appear to increase their VOC emission through wet cleaning and thus may affect the IAQ. Particles and dirt contain a great variety of both volatile and non-volatile substances, including allergens. While the volatile fraction can consist of more than 200 different VOCs including formaldehyde, the non-volatile fraction can contain considerable amounts (> 0.5%) of fatty acid salts and tensides (e.g. linear alkyl benzene sulphonates). The level of these substances can be high immediately after the cleaning process, but few studies have been conducted concerning this problem. The substances partly originate from the use of cleaning agents. Both types are suspected to be airway irritants. Cleaning activities generate dust, mostly by resuspension, but other occupant activities may also resuspend dust over longer periods of time. Personal sampling of VOCs and airborne dust gives higher results than stationary sampling. International bodies have proposed air sampling strategies. A variety of field sampling techniques for VOC and surface particle sampling is listed.
NASA Astrophysics Data System (ADS)
Tharim, Asniza Hamimi Abdul; Samad, Muna Hanim Abdul; Ismail, Mazran
2017-10-01
An Indoor Environmental Quality (IEQ) fieldwork assessment was conducted in the Platinum-rated GBI office building located in Putrajaya Malaysia. The aim of the study is to determine the current indoor performance of the selected green office building. The field measurement consists of several IEQ parameters counted under the GBI Malaysia namely the Thermal Comfort of temperature, relative humidity, air movement and heat transfer as well as solar radiation. This field measurement also comprises of the measurement for the background noise, visual lighting and Indoor Air Quality (IAQ) focusing on the aspect of carbon dioxide concentration. All the selected indoor parameters were measured for the period of five working days and the results were compared to the Malaysian Standard. Findings of the field measurement show good indoor performance of the Platinum rated office building that complies with the GBI standard. It is hoped that the research findings will be beneficial for future design and construction of office building intended to be rated under the GBI Malaysia.
Improving indoor air quality and thermal comfort in office building by using combination filters
NASA Astrophysics Data System (ADS)
Kabrein, H.; Yusof, M. Z. M.; Hariri, A.; Leman, A. M.; Afandi, A.
2017-09-01
Poor indoor air quality and thermal comfort condition in the workspace affected the occupants’ health and work productivity, especially when adapting the recirculation of air in heating ventilation and air-conditioning (HVAC) system. The recirculation of air was implemented in this study by mixing the circulated returned indoor air with the outdoor fresh air. The aims of this study are to assess the indoor thermal comfort and indoor air quality (IAQ) in the office buildings, equipped with combination filters. The air filtration technique consisting minimum efficiency reporting value (MERV) filter and activated carbon fiber (ACF) filter, located before the fan coil units. The findings of the study show that the technique of mixing recirculation air with the fresh air through the combination filters met the recommended thermal comfort condition in the workspace. Furthermore, the result of the post-occupancy evaluation (POE) and the environmental measurements comply with the ASHRAE 55 standard. In addition, the level of CO2 concentration continued to decrease during the period of the measurement.
Technology review: prototyping platforms for monitoring ambient conditions.
Afolaranmi, Samuel Olaiya; Ramis Ferrer, Borja; Martinez Lastra, Jose Luis
2018-05-08
The monitoring of ambient conditions in indoor spaces is very essential owing to the amount of time spent indoors. Specifically, the monitoring of air quality is significant because contaminated air affects the health, comfort and productivity of occupants. This research work presents a technology review of prototyping platforms for monitoring ambient conditions in indoor spaces. It involves the research on sensors (for CO 2 , air quality and ambient conditions), IoT platforms, and novel and commercial prototyping platforms. The ultimate objective of this review is to enable the easy identification, selection and utilisation of the technologies best suited for monitoring ambient conditions in indoor spaces. Following the review, it is recommended to use metal oxide sensors, optical sensors and electrochemical sensors for IAQ monitoring (including NDIR sensors for CO 2 monitoring), Raspberry Pi for data processing, ZigBee and Wi-Fi for data communication, and ThingSpeak IoT platform for data storage, analysis and visualisation.
Semple, S; Garden, C; Coggins, M; Galea, K S; Whelan, P; Cowie, H; Sánchez-Jiménez, A; Thorne, P S; Hurley, J F; Ayres, J G
2012-06-01
There are limited data describing pollutant levels inside homes that burn solid fuel within developed country settings with most studies describing test conditions or the effect of interventions. This study recruited homes in Ireland and Scotland where open combustion processes take place. Open combustion was classified as coal, peat, or wood fuel burning, use of a gas cooker or stove, or where there is at least one resident smoker. Twenty-four-hour data on airborne concentrations of particulate matter<2.5 μm in size (PM2.5), carbon monoxide (CO), endotoxin in inhalable dust and carbon dioxide (CO2), together with 2-3 week averaged concentrations of nitrogen dioxide (NO2) were collected in 100 houses during the winter and spring of 2009-2010. The geometric mean of the 24-h time-weighted-average (TWA) PM2.5 concentration was highest in homes with resident smokers (99 μg/m3--much higher than the WHO 24-h guidance value of 25 μg/m3). Lower geometric mean 24-h TWA levels were found in homes that burned coal (7 μg/m3) or wood (6 μg/m3) and in homes with gas cookers (7 μg/m3). In peat-burning homes, the average 24-h PM2.5 level recorded was 11 μg/m3. Airborne endotoxin, CO, CO2, and NO2 concentrations were generally within indoor air quality guidance levels. Little is known about indoor air quality (IAQ) in homes that burn solid or fossil-derived fuels in economically developed countries. Recent legislative changes have moved to improve IAQ at work and in enclosed public places, but there remains a real need to begin the process of quantifying the health burden that arises from indoor air pollution within domestic environments. This study demonstrates that homes in Scotland and Ireland that burn solid fuels or gas for heating and cooking have concentrations of air pollutants generally within guideline levels. Homes where combustion of cigarettes takes place have much poorer air quality. © 2011 John Wiley & Sons A/S.
PM2.5 in Urban and Rural Nursery Schools in Upper Silesia, Poland: Trace Elements Analysis
Mainka, Anna; Zajusz-Zubek, Elwira; Kaczmarek, Konrad
2015-01-01
Indoor air quality (IAQ) in nursery schools is an emerging public health challenge. Particular attention should be paid to younger children, because they are more vulnerable to air pollution than older children. Among air pollutants, fine particulate matter (PM2.5) is of the greatest interest mainly due to its strong association with acute and chronic effects on children’s health. In this paper, we present concentrations of PM2.5 and the composition of its trace elements at naturally ventilated nursery schools located in the area of Gliwice, Poland. The nursery schools were selected to characterize areas with different degrees of urbanization and traffic densities during the winter and spring seasons. The results indicate there is a problem with elevated concentrations of PM2.5 inside the examined classrooms. The children’s exposure to trace elements was different based on localization and season. PM2.5 concentration and its trace element composition have been studied using correlation coefficients between the different trace elements, the enrichment factor (EF) and principal component analysis (PCA). PCA allowed the identification of the three components: anthropogenic and geogenic sources (37.2%), soil dust contaminated by sewage sludge dumping (18.6%) and vehicular emissions (19.5%). PMID:26184269
Luksamijarulkul, Pipat; Suknongbung, Siranee; Vatanasomboon, Pisit; Sujirarut, Dusit
2017-03-01
A large number of migrants have move to cities in Thailand seeking employment. These people may be at increased risk for environmental health problems. We studied the health status, environmental living conditions and microbial indoor air quality (IAQ) among selected groups of migrant workers and their households in Mueang District, Samut Sakhon, central Thailand. We conducted a cross sectional study of 240 migrant workers and their households randomly selected by multistage sampling. The person responsible for hygiene at each studied household was interviewed using a structured questionnaire. Two indoor air samples were taken from each household (480 indoor air samples) to determine bacterial and fungal counts using a Millipore air tester; 240 outdoor air samples were collected for comparison. Ninety-nine point six percent of study subjects were Myanmar, 74.2% were aged 21-40 years, 91.7% had a primary school level education or lower and 53.7% had stayed in Thailand less than 5 years. Eight point three percent had a history of an underlying disease, 20.8% had a recent history of pulmonary tuberculosis in a family member within the previous year. Forty-three point eight percent had a current illness related to IAQ during a previous month. Twenty-one point three were current cigarette smokers, 15.0% were current alcohol consumers, and 5.0% exercises ≥3 times per week. Forty-nine point two percent never opened the windows of their bedrooms or living rooms for ventilation, 45% never cleaned their window screens, and 38.3% never put their pillows or mattresses in the sunlight. The mean(±SD) air bacterial count was 230(±229) CFU/m3 (outdoor air = 128±82 CFU/ m3), and the mean fungal count was 630(±842) CFU/m3 (outdoor air = 138±94 CFU/ m3). When the bacterial and fungal counts were compared with the guidelines of the American Conference of Governmental Industrial Hygienists, the bacterial counts in 6.5% of houses surveyed and the fungal counts in 28.8% of house surveyed were higher than the recommended levels (<500 CFU/m3). Bacterial and fungal counts in the sample households were not significantly correlated with household hygiene practice scores (p>0.05). There was a positive correlation between bacterial counts and fungal counts in household air samples, r=0.28, p<0.001.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Apte, Michael G.; Mendell, Mark J.; Sohn, Michael D.
Through mass-balance modeling of various ventilation scenarios that might satisfy the ASHRAE 62.1 Indoor Air Quality (IAQ) Procedure, we estimate indoor concentrations of contaminants of concern (COCs) in California “big box” stores, compare estimates to available thresholds, and for selected scenarios estimate differences in energy consumption. Findings are intended to inform decisions on adding performance-based approaches to ventilation rate (VR) standards for commercial buildings. Using multi-zone mass-balance models and available contaminant source rates, we estimated concentrations of 34 COCs for multiple ventilation scenarios: VRmin (0.04 cfm/ft2 ), VRmax (0.24 cfm/ft2 ), and VRmid (0.14 cfm/ft2 ). We compared COC concentrationsmore » with available health, olfactory, and irritant thresholds. We estimated building energy consumption at different VRs using a previously developed EnergyPlus model. VRmax did control all contaminants adequately, but VRmin did not, and VRmid did so only marginally. Air cleaning and local ventilation near strong sources both showed promise. Higher VRs increased indoor concentrations of outdoor air pollutants. Lowering VRs in big box stores in California from VRmax to VRmid would reduce total energy use by an estimated 6.6% and energy costs by 2.5%. Reducing the required VRs in California’s big box stores could reduce energy use and costs, but poses challenges for health and comfort of occupants. Source removal, air cleaning, and local ventilation may be needed at reduced VRs, and even at current recommended VRs. Also, alternative ventilation strategies taking climate and season into account in ventilation schedules may provide greater energy cost savings than constant ventilation rates, while improving IAQ.« less
Biological air contamination in elderly care centers: geria project.
Aguiar, Lívia; Mendes, Ana; Pereira, Cristiana; Neves, Paula; Mendes, Diana; Teixeira, João Paulo
2014-01-01
Indoor air quality (IAQ) affects health particularly in susceptible individuals such as the elderly. It has been estimated that the older population spends approximately 19-20 h/d indoors, and the majority of the elderly spend all of their time indoors in elderly care centers (ECC). Older individuals may be particularly at risk of exposure to detrimental effects from pollutants, even at low concentrations, due to common and multiple underlying chronic diseases that increase susceptibility. This study, aimed to assess the impact of indoor biological agents in 22 ECC located in Porto, was conducted during summer and winter from November 2011 to August 2013 at a total of 141 areas within dining rooms, drawing rooms, medical offices, and bedrooms (including the bedridden). Air sampling was carried out with a microbiological air sampler (Merck MAS-100) and using tryptic soy agar for bacteria and malt extract agar for fungi. The results obtained were compared with the recently revised Portuguese standards. In winter, mean fungi concentration exceeded reference values, while bacteria concentrations were within the new standards in both seasons. The main fungi species found indoors were Cladosporium (73%) in summer and Penicillium (67%) in winter. Aspergillus fumigatus, Aspergillus niger, and Aspergillus flavus, known potential pathogenic/toxigenic species, were also identified. Although the overall rate and mean values of bacteria and fungi found in ECC indoor air met Portuguese legislation, some concern is raised by the presence of pathogenic microorganisms. Simple measures, like opening windows and doors to promote air exchange and renewal, may improve effectiveness in enhancing IAQ.
Connecting and Networking for Schools
Resources for connecting and networking for schools through e-newsletters, finding school IAQ Champions and other EPA school programs such as Asthma, Energy Star, Clean School Bus USA, School Flag, etc.
Preparation and response to weather-related and man-made emergencies is particularly important when it comes to indoor environments, since humans spend most of their time indoors, and rely on indoor spaces for shelter.
EPA recommends testing all schools for radon. As part of an effective IAQ management program, schools can take simple steps to test for radon and reduce risks to occupants if high radon levels are found.
NASA Astrophysics Data System (ADS)
Er, C. M.; Sunar, N. M.; Leman, A. M.; Khalid, A.; Ali, R.; Zaidi, E.; Azhar, A. T. S.
2018-04-01
Surface-growing indoor and outdoor fungi were assessed using swabbing method to investigate the indoor contamination. The painted wall surface samples were collected from two institutional buildings (B1 and B2) of a university in southern Peninsular Malaysia; indoors and outdoors. The mould concentrations varied widely between indoor and outdoor surface samples of both buildings. The total indoor surface-growing mould concentration (8776.49 CFU/cm2) is significantly higher (p<0.05) than the total concentration of outdoor surface growing mould (209.91 CFU/cm2). Respectively, the mean concentration of indoor surface-growing mould (18920.13 CFU/cm2 for B1 and 3704.67 CFU/cm2 for B2) is significantly higher than their outdoor counterparts (99.95 CFU/cm2 for b1 and for 319.86 CFU/cm2 b2) at these buildings. Besides, various air quality parameters (relative humidity, temperature and air velocity) were also measured indoors and outdoors during the study and violation of the guideline provided by ICOP-IAQ 2010 were proven in indoor environment in both buildings. The results of this assessment showed that the indoor environments of both institutional buildings were contaminated by the surface-growing mould. It also suggested the faulty designs and/or usages of building material in these institutional buildings contributed toward the contamination. An innovative solution is needed to correct the problems.
INSIDE IAQ (SPRING/SUMMER 2001)
The newsletter discusses results of research on volatile organic compound (VOC) emissions from photocopier toners, hazardous air pollutants (HAPs) emitted by shower curtains, asthma intervention in Boston public housing, air pollution from burning candles, and the impact of ozone...
Vitality of plants to live in the indoor environment
NASA Astrophysics Data System (ADS)
Shamsuri, Mohd Mahathir Suhaimi; Leman, A. M.; Hariri, Azian; Idris, Ahmad Fu'ad; Afandi, Azizi
2017-09-01
Indoor air quality (IAQ) is generally a public concern because 90% of people spend their time indoor. IAQ must be preserved wisely to guarantee the health of the building occupants. One of the ways to maintain the quality of air is by placing plants in the building. However, all plants come from the outdoor, and the environment is different compared to indoor. Environmental factors such as temperature and light will absolutely affect the growth of the plant. Light and temperature that are too bright or too deem can wither the plants. Nevertheless, certain plant is capable of adapting with different situation after assimilation process has been conducted. This study intends to analyze the capacity of seven selected plants (Anthurium, Dumb Cane, Golden Pothos, Kadaka Fern, Prayer Plant, Spider Plant, and Syngonium) to live in an indoor environment. The vitality of plants is based on photosynthetic level that is measured using leaf - chamber (LI-COR 6400). Two groups of plants were located in indoor and outdoor (indigenous location) setting, and were allowed to assimilate for two months before measurement were carried out. The results for the plant located indoor shows that only Spider Plant cannot perform photosynthesis under 300 lux, where the photosynthetic value remains negative. Meanwhile, other plants such as Anthurium, Dumb Cane, Golden Pothos, Kadaka Fern, Prayer Plant, and Syngonium that were left indoor showed similar 300 lux in which conform the ability of the plants to perform photosynthesis with the value of 0.3, 0.15, 0.35, 0.1, 0.15, and 0.1. In comparison, all of the plants that were stationed indoor and outdoor (except Spider Plant), the light compensation point (LCP) for indoor shows smaller value than the outdoor. This is because all the indoor plants had down - regulated their photosynthesis process by becoming more sensitive to light after their assimilation. From this study, it can be concluded that all plants except Spider Plant is able to live in indoor environment, and can be further studied to treat the indoor air.
IAQ Scientific Findings Resource Bank
This effort is being conducted under an interagency agreement between the US EPA and the US Department of Energy- the Lawrence Berkeley National Laboratory (LBNL). Under this project, LBNL will conduct literature reviews and analyses which quantify the health and productivity be...
Assessment of indoor PM2.5 in different residential environments
NASA Astrophysics Data System (ADS)
Yassin, Mohamed F.; AlThaqeb, Bothaina E. Y.; Al-Mutiri, Eman A. E.
2012-09-01
The indoor air quality (IAQ) as assessed by PM2.5 (particulate matter with an aerodynamic diameter of less than 2.5 μm) was measured at indoor settings in various residential houses which were located in different local environments across Kuwait. The indoor house settings included kitchen, living room, and bedrooms. Samples were collected from houses over 24 h. PM2.5 was estimated using a Dust-Trak personal sampler. Results were analyzed and compared with the US Environmental Protection Agencies (EPA) and World Health Organization (WHO) standards and guidelines. The results demonstrated that kitchens have the highest PM2.5 concentration probably due to cooking activities; the bedroom has the lowest PM2.5 concentration. The study shows that Kuwait indoor residential pollution is among the worst in comparison with other countries.
Webinar: Green Cleaning for Improved Health: The Return on Investment of Green Cleaning in Schools
A page to register to view the June 22, 2017, webinar in the IAQ Knowledge-to-Action Professional Training Webinar Series: Green Cleaning for Improved Health: The Return on Investment of Green Cleaning in Schools
IAQ MODEL FOR WINDOWS - RISK VERSION 1.0 USER MANUAL
The manual describes the use of the computer model, RISK, to calculate individual exposure to indoor air pollutants from sources. The model calculates exposure due to individual, as opposed to population, activity patterns and source use. The model also provides the capability to...
ANALYSIS OF HOUSEHOLD WATER USE BEHAVIOR FOR USE AS IAQ MODEL PARAMETERS
Chemicals brought into the home through the domestic water supply, result in human exposure via the three principal routes: ingestion, inhalation, and dermal contact. Disinfection byproducts resulting from the treatment of municipal water supplies lead to the formation of a mix...
Identifying Sources of Volatile Organic Compounds and Aldehydes in a High Performance Building
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ortiz, Anna C.; Russell, Marion; Lee, Wen-Yee
The developers of the Paharpur Business Center (PBC) and Software Technology Incubator Park in New Delhi, India offer an environmentally sustainable building with a strong emphasis on energy conservation, waste minimization and superior indoor air quality (IAQ). To achieve the IAQ goal, the building utilizes a series of air cleaning technologies for treating the air entering the building. These technologies include an initial water wash followed by ultraviolet light treatment and biolfiltration using a greenhouse located on the roof and numerous plants distributed throughout the building. Even with the extensive treatment of makeup air and room air in the PBC,more » a recent study found that the concentrations of common volatile organic compounds and aldehydes appear to rise incrementally as the air passes through the building from the supply to the exhaust. This finding highlights the need to consider the minimization of chemical sources in buildings in combination with the use of advanced air cleaning technologies when seeking to achieve superior IAQ. The goal of this project was to identify potential source materials for indoor chemicals in the PBC. Samples of building materials, including wood paneling (polished and unpolished), drywall, and plastic from a hydroponic drum that was part of the air cleaning system, were collected from the building for testing. All materials were collected from the PBC building and shipped to the Lawrence Berkeley National Laboratory (LBNL) for testing. The materials were pre-conditioned for two different time periods before measuring material and chemical specific emission factors for a range of VOCs and Aldehydes. Of the six materials tested, we found that the highest emitter of formaldehyde was new plywood paneling. Although polish and paint contribute to some VOC emissions, the main influence of the polish was in altering the capacity of the surface to accumulate formaldehyde. Neither the new nor aged polish contributed significantly to formaldehyde emissions. The VOC emission stream (excluding formaldehyde) was composed of up to 18 different chemicals and the total VOC emissions ranged in magnitude from 7 mu g/m2/h (old wood with old polish) to>500 mu g/m2/h (painted drywall). The formaldehyde emissions from drywall and old wood with either new or old polish were ~;;15 mu g/m2/h while the new wood material emitted>100 mu g/m2/h. However, when the projected surface area of each material in the building was considered, the new wood, old wood and painted drywall material all contributed substantially to the indoor formaldehyde loading while the coatings contributed primarily to the VOCs.« less
ASSESSMENT OF VENTILATION RATES IN 100 BASE OFFICE BUILDINGS
The U.S. EPA's Office of Radiation and Indoor Air studied 100 public and private office buildings across the U.S. from 1994-1998. The purpose of the study, entitled The Building Assessment Survey and Evaluation Study (BASE), was to: a) provide a distribution of IAQ, building, and...
NASA Astrophysics Data System (ADS)
Mendez, Maxence; Blond, Nadège; Blondeau, Patrice; Schoemaecker, Coralie; Hauglustaine, Didier A.
2015-12-01
INCA-Indoor, a new indoor air quality (IAQ) model, has been developed to simulate the concentrations of volatile organic compounds (VOC) and oxidants considering indoor air specific processes such as: emission, ventilation, surface interactions (sorption, deposition, uptake). Based on the detailed version of SAPRC-07 chemical mechanism, INCA-Indoor is able to analyze the contribution of the production and loss pathways of key chemical species (VOCs, oxidants, radical species). The potential of this model has been tested through three complementary analyses: a comparison with the most detailed IAQ model found in the literature, focusing on oxidant species; realistic scenarios covering a large range of conditions, involving variable OH sources like HONO; and the investigation of alkenes ozonolysis under a large range of indoor conditions that can increase OH and HO2 concentrations. Simulations have been run changing nitrous acid (HONO) concentrations, NOx levels, photolysis rates and ventilation rates, showing that HONO can be the main source of indoor OH. Cleaning events using products containing D-limonene have been simulated at different periods of the day. These scenarios show that HOX concentrations can significantly increase in specific conditions. An assessment of the impact of indoor chemistry on the potential formation of secondary species such as formaldehyde (HCHO) and acetaldehyde (CH3CHO) has been carried out under various room configuration scenarios and a study of the HOx budget for different realistic scenarios has been performed. It has been shown that, under the simulation conditions, formaldehyde can be affected by oxidant concentrations via chemical production which can account for more than 10% of the total production, representing 6.5 ppb/h. On the other hand, acetaldehyde production is affected more by oxidation processes. When the photolysis rates are high, chemical processes are responsible for about 50% of the total production of acetaldehyde (9 ppb/h).
Indoor air quality and the law in Singapore.
Chan, P
1999-12-01
With the greater use of air-conditioned offices in Singapore, achieving good indoor air quality has become an important issue. The laws that impose duties upon designers and contractors with respect to the design and construction of air-conditioning and mechanical ventilation (ACMV) systems are set out in the Building Control Regulations and the Singapore Standard Code of Practice for Mechanical Ventilation and Air-conditioning in Buildings (hereinafter "SS CP 13:1980"). ACMV maintenance is governed by the Environmental Public Health Act, the Building and Common Property (Maintenance and Management) Act, and the Land Titles (Strata) Act, as well as by lease or tenancy agreements. Designers, contractors, developers, building owners and management corporations may also be liable to the workers, occupants and other premises users for indoor air quality (IAQ)-related injuries under the general principles of contract and tort. Recently, the Guidelines for Good Indoor Air Quality in Office Premises was issued by the Ministry of Environment to complement SS CP 13:1980 toward improving the indoor air quality of air-conditioned office premises. Although the Guidelines have no statutory effect, they may be adopted as contractual requirements in construction, lease and maintenance contracts. They may also be used to determine the relevant standard of duty of care required to discharge tortious liability. This paper looks at the existing laws and rules affecting the design, construction and maintenance of air-conditioned offices in light of Part III of the Ministry's Guidelines.
Serendipitous Policy Implications from Class-Size-Initiated Inquiry: IAQ?
ERIC Educational Resources Information Center
Achilles, C. M.; Prout, Jean; Finn, J. D.; Bobbett, Gordon C.
The level of carbon dioxide in a classroom can have a significant negative effect on teaching and learning. Carbon dioxide (CO2) level is affected by class size and time of day. Six urban schools were studied to characterize the effects of these three factors on different class sizes. Carbon monoxide, CO2, temperature, and relative humidity…
ERIC Educational Resources Information Center
Nnadi, Matthias; Rosser, Mike
2014-01-01
The "individualised accounting questions" (IAQ) technique set out in this paper encourages independent active learning. It enables tutors to set individualised accounting questions and construct an answer grid that can be used for any number of students, with numerical values for each student's answers based on their student enrolment…
The real and subjective indoor environmental quality in schools.
Mečiarová, Ľudmila; Vilčeková, Silvia; Krídlová Burdová, Eva; Kapalo, Peter; Mihaľová, Nikola
2018-02-01
Investigation of IEQ and subjective evaluation of IEQ by pupils is the main objective of this research work. For the monitoring two classrooms in primary school and two classrooms in art school were chosen. Very high CO 2 levels were determined in both investigated schools. In three of four classrooms the statistically significant differences (p < 0.01) were reported between TVOC levels in autumn and spring. The recommended value for TVOC levels was exceeded in the range from 52 % to 53 % in autumn and from 52 % to 70 % in spring. Significant (p < 0.05) seasonal changes were found also for PM concentrations in each classroom. Significance difference in perception of IEQ factors between genders were observed for IAQ. This study showed a good consistency between data obtained from the measurement and data from the questionnaire study and thus, pointed to the good ability of pupils to evaluate the IEQ in their classrooms.
Study on Decomposition of Indoor Air Contaminants by Pulsed Atmospheric Microplasma
Shimizu, Kazuo; Kuwabara, Tomoya; Blajan, Marius
2012-01-01
Decomposition of formaldehyde (HCHO) by a microplasma reactor in order to improve Indoor Air Quality (IAQ) was achieved. HCHO was removed from air using one pass through reactor treatment (5 L/min). From an initial concentration of HCHO of 0.7 ppm about 96% was removed in one pass treatment using a discharge power of 0.3 W provided by a high voltage amplifier and a Marx Generator with MOSFET switches as pulsed power supplies. Moreover microplasma driven by the Marx Generator did not generate NOx as detected by a chemiluminescence NOx analyzer. In the case of large volume treatment the removal ratio of HCHO (initial concentration: 0.5 ppm) after 60 minutes was 51% at 1.2 kV when using HV amplifier considering also a 41% natural decay ratio of HCHO. The removal ratio was 54% at 1.2 kV when a Marx Generator energized the electrodes with a 44% natural decay ratio after 60 minutes of treatment. PMID:23202173
Jang, Hong-Seok; Xing, Shuli; Lee, Malrey; Lee, Young-Keun; So, Seung-Young
2016-05-01
In this study, an artificial neural networks study was carried out to predict the quantity of radon of Granulated Blast Furnace Slag (GBFS) cement mortar. A data set of a laboratory work, in which a total of 3 mortars were produced, was utilized in the Artificial Neural Networks (ANNs) study. The mortar mixture parameters were three different GBFS ratios (0%, 20%, 40%). Measurement radon of moist cured specimens was measured at 3, 10, 30, 100, 365 days by sensing technology for continuous monitoring of indoor air quality (IAQ). ANN model is constructed, trained and tested using these data. The data used in the ANN model are arranged in a format of two input parameters that cover the cement, GBFS and age of samples and, an output parameter which is concentrations of radon emission of mortar. The results showed that ANN can be an alternative approach for the predicting the radon concentration of GBFS mortar using mortar ingredients as input parameters.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Less, Brennan; Walker, Iain; Tang, Yihuan
2014-06-01
Smart ventilation systems use controls to ventilate more during those periods that provide either an energy or IAQ advantage (or both) and less during periods that provide a dis advantage. Using detailed building simulations, this study addresses one of the simplest and lowest cost types of smart controllers —outdoor temperature- based control. If the outdoor temperature falls below a certain cut- off, the fan is simply turned off. T he main principle of smart ventilation used in this study is to shift ventilation from time periods with large indoor -outdoor temperature differences, to periods where these differences are smaller, andmore » their energy impacts are expected to be less. Energy and IAQ performance are assessed relative to a base case of a continuously operated ventilation fan sized to comply with ASHRAE 62.2-2013 whole house ventilation requirements. In order to satisfy 62.2-2013, annual pollutant exposure must be equivalent between the temperature controlled and continuous fan cases. This requires ventilation to be greater than 62.2 requirements when the ventilation system operates. This is achieved by increasing the mechanical ventilation system air flow rates.« less
Size and seasonal distributions of airborne bioaerosols in commuting trains
NASA Astrophysics Data System (ADS)
Wang, Ya-Fen; Wang, Che-Hsu; Hsu, Kai-Lin
2010-11-01
Aerobiological studies in commuting trains in northern Taiwan were carried out from August, 2007 until July, 2008. Two six-stage (>7 μm, 4.7˜7 μm, 3.3˜4.7 μm, 2.1˜3.3 μm, 1.1˜2.1 μm, 0.65˜1.1 μm) cascade impactors of 400 orifices were used to collect viable bacteria and fungi, respectively. The levels of carbon monoxide (CO), carbon dioxide (CO 2), formaldehyde (HCHO), temperature, and relative humidity in the commuting trains were also recorded during the sampling period. Results show that bacterial concentrations ranged from 25 to 1530 CFU m -3, and averaged 417 CFU m -3. The fungal concentrations ranged from 45 to 1906 CFU m -3, and averaged 413 CFU m -3. Additionally, the highest fractions occurred in the fifth stage (1.1˜2.1 μm) for both bacteria and fungi. The respirable fractions, Rb and Rf, for bacteria and fungi were 62.8% and 81.4%, respectively, which are higher than those in other studies. Furthermore, the bacterial concentration reached its highest level in autumn, and its lowest level in winter. However, the fungal concentration was highest in spring and lowest in winter. Though the total bacterial or fungal concentration did not exceed the recommendation standard in Taiwan, the relatively high respirable fraction in commuting trains probably implies a higher adverse health risk for sensitive commuters. This study further conducted multiple regression analysis to determine the relationship of various stage fractions of airborne bacteria and fungi with indoor air pollutants (CO and HCHO) and environmental parameters (CO 2, temperature, and relative humidity). The correlation coefficients of multiple regression analysis for total bacteria and fungi concentrations with indoor air pollutants and environmental parameters were 0.707 ( p < 0.00376) and 0.612 ( p < 0.00471), respectively. There are currently no formally regulated laws for indoor air quality (IAQ) in Taiwan, and this preliminary study can provide references to the Taiwan government on IAQ management.
The report gives results of a series of computer runs using the DOE-2.1E building energy model, simulating a small office in a hot, humid climate (Miami). These simulations assessed the energy and relative humidity (RH) penalties when the outdoor air (OA) ventilation rate is inc...
Cleary, Erika; Asher, Mary; Olawoyin, Richard; Zhang, Kuangyuan
2017-11-01
Ambient air pollution is a public health issue which could potentially exacerbate pre-existing respiratory conditions and contribute to increases in asthma incidence. This study aims to address gaps in understanding how IAQ is impacted by outdoor air quality, which was done by sampling for indoor gaseous and particulate pollutants in residence and facilities near the sources of pollution. The study areas were selected due to non-attainment status with air quality standards, as well as demographic and socioeconomic status of those residing in these areas. Samples are obtained from five locations around the study areas. The sampling procedure involves active sampling methodologies for particulate matter (PM) and gases. Average volatile organic compounds (VOC) levels of 2.71 ppm were measured at a location, while the average particulate matter (PM) concentrations in three study locations were; 15,979 pt/cc, 9533 pt/cc, 5267 pt/cc respectively, which exceeded clean background environment level of 500-2000 pt/cc. All locations had average CO concentrations above 0.3 ppm, which is potentially associated with elevated asthma symptoms. Results demonstrated that facilities in the study area have increased levels of indoor air pollutants that potentially increase asthma and respiratory issues. The study concludes that particulate and gaseous pollutant levels in the study areas are a concerning human health issue. The study outcomes have significant implications for air quality exposure modeling and potential exposure mitigation strategies, which are expected to facilitate the implementation of public policies for improved human health conditions. Copyright © 2017 Elsevier Ltd. All rights reserved.
Procedures and Standards for Residential Ventilation System Commissioning: An Annotated Bibliography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stratton, J. Chris; Wray, Craig P.
2013-04-01
Beginning with the 2008 version of Title 24, new homes in California must comply with ANSI/ASHRAE Standard 62.2-2007 requirements for residential ventilation. Where installed, the limited data available indicate that mechanical ventilation systems do not always perform optimally or even as many codes and forecasts predict. Commissioning such systems when they are installed or during subsequent building retrofits is a step towards eliminating deficiencies and optimizing the tradeoff between energy use and acceptable IAQ. Work funded by the California Energy Commission about a decade ago at Berkeley Lab documented procedures for residential commissioning, but did not focus on ventilation systems.more » Since then, standards and approaches for commissioning ventilation systems have been an active area of work in Europe. This report describes our efforts to collect new literature on commissioning procedures and to identify information that can be used to support the future development of residential-ventilation-specific procedures and standards. We recommend that a standardized commissioning process and a commissioning guide for practitioners be developed, along with a combined energy and IAQ benefit assessment standard and tool, and a diagnostic guide for estimating continuous pollutant emission rates of concern in residences (including a database that lists emission test data for commercially-available labeled products).« less
Children's Exposure to Radon in Nursery and Primary Schools.
Branco, Pedro T B S; Nunes, Rafael A O; Alvim-Ferraz, Maria C M; Martins, Fernando G; Sousa, Sofia I V
2016-03-30
The literature proves an evident association between indoor radon exposure and lung cancer, even at low doses. This study brings a new approach to the study of children's exposure to radon by aiming to evaluate exposure to indoor radon concentrations in nursery and primary schools from two districts in Portugal (Porto and Bragança), considering different influencing factors (occupation patterns, classroom floor level, year of the buildings' construction and soil composition of the building site), as well as the comparison with IAQ standard values for health protection. Fifteen nursery and primary schools in the Porto and Bragança districts were considered: five nursery schools for infants and twelve for pre-schoolers (seven different buildings), as well as eight primary schools. Radon measurements were performed continuously. The measured concentrations depended on the building occupation, classroom floor level and year of the buildings' construction. Although they were in general within the Portuguese legislation for IAQ, exceedances to international standards were found. These results point out the need of assessing indoor radon concentrations not only in primary schools, but also in nursery schools, never performed in Portugal before this study. It is important to extend the study to other microenvironments like homes, and in time to estimate the annual effective dose and to assess lifetime health risks.
Ventilation rates in recently constructed U.S. school classrooms.
Batterman, S; Su, F-C; Wald, A; Watkins, F; Godwin, C; Thun, G
2017-09-01
Low ventilation rates (VRs) in schools have been associated with absenteeism, poorer academic performance, and teacher dissatisfaction. We measured VRs in 37 recently constructed or renovated and mechanically ventilated U.S. schools, including LEED and EnergyStar-certified buildings, using CO 2 and the steady-state, build-up, decay, and transient mass balance methods. The transient mass balance method better matched conditions (specifically, changes in occupancy) and minimized biases seen in the other methods. During the school day, air change rates (ACRs) averaged 2.0±1.3 hour -1 , and only 22% of classrooms met recommended minimum ventilation rates. HVAC systems were shut off at the school day close, and ACRs dropped to 0.21±0.19 hour -1 . VRs did not differ by building type, although cost-cutting and comfort measures resulted in low VRs and potentially impaired IAQ. VRs were lower in schools that used unit ventilators or radiant heating, in smaller schools and in larger classrooms. The steady-state, build-up, and decay methods had significant limitations and biases, showing the need to confirm that these methods are appropriate. Findings highlight the need to increase VRs and to ensure that energy saving and comfort measures do not compromise ventilation and IAQ. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Children’s Exposure to Radon in Nursery and Primary Schools
Branco, Pedro T. B. S.; Nunes, Rafael A. O.; Alvim-Ferraz, Maria C. M.; Martins, Fernando G.; Sousa, Sofia I. V.
2016-01-01
The literature proves an evident association between indoor radon exposure and lung cancer, even at low doses. This study brings a new approach to the study of children’s exposure to radon by aiming to evaluate exposure to indoor radon concentrations in nursery and primary schools from two districts in Portugal (Porto and Bragança), considering different influencing factors (occupation patterns, classroom floor level, year of the buildings’ construction and soil composition of the building site), as well as the comparison with IAQ standard values for health protection. Fifteen nursery and primary schools in the Porto and Bragança districts were considered: five nursery schools for infants and twelve for pre-schoolers (seven different buildings), as well as eight primary schools. Radon measurements were performed continuously. The measured concentrations depended on the building occupation, classroom floor level and year of the buildings’ construction. Although they were in general within the Portuguese legislation for IAQ, exceedances to international standards were found. These results point out the need of assessing indoor radon concentrations not only in primary schools, but also in nursery schools, never performed in Portugal before this study. It is important to extend the study to other microenvironments like homes, and in time to estimate the annual effective dose and to assess lifetime health risks. PMID:27043596
The effect of environmental parameters to dust concentration in air-conditioned space
NASA Astrophysics Data System (ADS)
Ismail, A. M. M.; Manssor, N. A. S.; Nalisa, A.; Yahaya, N.
2017-08-01
Malaysia has a wet and hot climate, therefore most of the spaces are air conditioned. The environment might affect dust concentration inside a space and affect the indoor air quality (IAQ). The main objective of this study is to study the dust concentration collected inside enclosed air-conditioned space. The measurement was done physically at four selected offices and two classrooms using a number of equipment to measure the dust concentration and environmental parameters which are temperature and relative air humidity. It was found that the highest dust concentration produced in office (temperature of 24.7°C, relative humidity of 66.5%) is 0.075 mg/m3, as compared to classroom, the highest dust concentration produced is 0.060 mg/m3 office (temperature of 25.9°C, relative humidity of 64.0%). However, both measurements show that value still within the safety level set by DOSH Malaysia (2005-2010) and ASHRAE 62.2 2016. The office contained higher dust concentration compared to classroom because of frequent movement transpires daily due to the functional of the offices.
A Meta-Analysis of Single-Family Deep Energy Retrofit Performance in the U.S.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Less, Brennan; Walker, Iain
2014-08-01
The current state of Deep Energy Retrofit (DER) performance in the U.S. has been assessed in 116 homes in the United States, using actual and simulated data gathered from the available domestic literature. Substantial airtightness reductions averaging 63% (n=48) were reported (two- to three-times more than in conventional retrofits), with average post-retrofit airtightness of 4.7 Air Changes per House at 50 Pascal (ACH50) (n=94). Yet, mechanical ventilation was not installed consistently. In order to avoid indoor air quality (IAQ) issues, all future DERs should comply with ASHRAE 62.2-2013 requirements or equivalent. Projects generally achieved good energy results, with average annualmore » net-site and net-source energy savings of 47%±20% and 45%±24% (n=57 and n=35), respectively, and carbon emission reductions of 47%±22% (n=23). Net-energy reductions did not vary reliably with house age, airtightness, or reported project costs, but pre-retrofit energy usage was correlated with total reductions (MMBtu).« less
Evaluation of fungal growth on cellulose-containing and inorganic ceiling tile.
Karunasena, E; Markham, N; Brasel, T; Cooley, J D; Straus, D C
2001-01-01
Buildings with poor indoor air quality (IAQ) frequently have many areas with surface fungal contamination. Studies have demonstrated that certain fungal genera (e.g., Cladosporium, Penicillium, and Stachybotrys) are able to grow on building materials such as wallpaper, drywall, and ceiling tiles, particularly after water damage has occurred. Due to the increasing awareness of sick building syndrome (SBS), it has become essential to identify building materials that prevent the interior growth of fungi. The objective of this study was to identify building materials that would not support the growth of certain fungal genera, regardless of whether an external food source was made available. The growth of three fungal genera (Cladosporium, Penicillium, and Stachybotrys) was evaluated on cellulose-containing ceiling tile (CCT) and inorganic ceiling tile (ICT). Both types of ceiling tile were exposed to environmental conditions which can occur inside a building. Our results show that ICT did not support the growth of these three fungal genera while CCT did. Our data demonstrate that ICT could serve as an ideal replacement for CCT.
Goyal, Radha; Khare, Mukesh
2011-05-01
Assessment of indoor air quality (IAQ) in classrooms of school buildings is of prime concern due to its potential effects on student's health and performance as they spend a substantial amount of their time (6-7 h per day) in schools. A number of airborne contaminants may be present in urban school environment. However, respirable suspended particulate matter (RSPM) is of great significance as they may significantly affect occupants' health. The objectives of the present study are twofold, one, to measure the concentrations of PM(10) (<10 microm), PM(2.5) (<2.5 microm), and PM(1.0) (<1.0 microm) in naturally ventilated classrooms of a school building located near a heavy-traffic roadway (9,755 and 4,296 vehicles/hour during weekdays and weekends, respectively); and second, to develop single compartment mass balance-based IAQ models for PM(10) (NVIAQM(pm10)), PM(2.5) (NVIAQM(pm2.5)), and PM(1.0) (NVIAQM(pm1.0)) for predicting their indoor concentrations. Outdoor RSPM levels and classroom characteristics, such as size, occupancy level, temperature, relative humidity, and CO(2) concentrations have also been monitored during school hours. Predicted indoor PM(10) concentrations show poor correlations with observed indoor PM(10) concentrations (R (2) = 0.028 for weekdays, and 0.47 for weekends). However, a fair degree of agreement (d) has been found between observed and predicted concentrations, i.e., 0.42 for weekdays and 0.59 for weekends. Furthermore, NVIAQM(pm2.5) and NVIAQM(pm1.0) results show good correlations with observed concentrations of PM(2.5) (R(2) = 0.87 for weekdays and 0.9 for weekends) and PM(1.0) (R(2) = 0.86 for weekdays and 0.87 for weekends). NVIAQM(pm10) shows the tendency to underpredict indoor PM(10) concentrations during weekdays as it does not take into account the occupant's activities and its effects on the indoor concentrations during the class hours. Intense occupant's activities cause resuspension or delayed deposition of PM(10). The model results further suggests conductance of experimental and physical simulation studies on dispersion of particulates indoors to investigate their resuspension and settling behavior due to occupant's activities/movements. The models have been validated at three different classroom locations of the school site. Sensitivity analysis of the models has been performed by varying the values of mixing factor (k) and newly introduced parameter R(c). The results indicate that the change in values of k (0.33 to 1.00) does not significantly affect the model performance. However, change in value of R(c) (0.001 to 0.500) significantly affects the model performance.
Indoor air quality in energy-efficient dwellings: Levels and sources of pollutants.
Derbez, M; Wyart, G; Le Ponner, E; Ramalho, O; Ribéron, J; Mandin, C
2018-03-01
Worldwide, public policies are promoting energy-efficient buildings and accelerating the thermal renovation of existing buildings. The effects of these changes on the indoor air quality (IAQ) in these buildings remain insufficiently understood. In this context, a field study was conducted in 72 energy-efficient dwellings to describe the pollutants known to be associated with health concerns. Measured parameters included the concentrations of 19 volatile organic compounds and aldehydes, nitrogen dioxide, particulate matter (PM 2.5 ), radon, temperature, and relative humidity. The air stuffiness index and night-time air exchange rate were calculated from the monitored carbon dioxide (CO 2 ) concentrations. Indoor and outdoor measurements were performed at each dwelling during 1 week in each of the two following seasons: heating and non-heating. Moreover, questionnaires were completed by the occupants to characterize the building, equipment, household, and occupants' habits. Perspective on our results was provided by previous measurements made in low-energy European dwellings. Statistical comparisons with the French housing stock and a pilot study showed higher concentrations of terpenes, that is, alpha-pinene and limonene, and hexaldehyde in our study than in previous studies. Alpha-pinene and hexaldehyde are emitted by wood or wood-based products used for the construction, insulation, decoration, and furnishings of the dwellings, whereas limonene is more associated with discontinuous sources related to human activities. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Volatile Organic Compounds (VOCs) in Conventional and High Performance School Buildings in the U.S.
Zhong, Lexuan; Su, Feng-Chiao; Batterman, Stuart
2017-01-21
Exposure to volatile organic compounds (VOCs) has been an indoor environmental quality (IEQ) concern in schools and other buildings for many years. Newer designs, construction practices and building materials for "green" buildings and the use of "environmentally friendly" products have the promise of lowering chemical exposure. This study examines VOCs and IEQ parameters in 144 classrooms in 37 conventional and high performance elementary schools in the U.S. with the objectives of providing a comprehensive analysis and updating the literature. Tested schools were built or renovated in the past 15 years, and included comparable numbers of conventional, Energy Star, and Leadership in Energy and Environmental Design (LEED)-certified buildings. Indoor and outdoor VOC samples were collected and analyzed by thermal desorption, gas chromatography and mass spectroscopy for 94 compounds. Aromatics, alkanes and terpenes were the major compound groups detected. Most VOCs had mean concentrations below 5 µg/m³, and most indoor/outdoor concentration ratios ranged from one to 10. For 16 VOCs, the within-school variance of concentrations exceeded that between schools and, overall, no major differences in VOC concentrations were found between conventional and high performance buildings. While VOC concentrations have declined from levels measured in earlier decades, opportunities remain to improve indoor air quality (IAQ) by limiting emissions from building-related sources and by increasing ventilation rates.
Volatile Organic Compounds (VOCs) in Conventional and High Performance School Buildings in the U.S.
Zhong, Lexuan; Su, Feng-Chiao; Batterman, Stuart
2017-01-01
Exposure to volatile organic compounds (VOCs) has been an indoor environmental quality (IEQ) concern in schools and other buildings for many years. Newer designs, construction practices and building materials for “green” buildings and the use of “environmentally friendly” products have the promise of lowering chemical exposure. This study examines VOCs and IEQ parameters in 144 classrooms in 37 conventional and high performance elementary schools in the U.S. with the objectives of providing a comprehensive analysis and updating the literature. Tested schools were built or renovated in the past 15 years, and included comparable numbers of conventional, Energy Star, and Leadership in Energy and Environmental Design (LEED)-certified buildings. Indoor and outdoor VOC samples were collected and analyzed by thermal desorption, gas chromatography and mass spectroscopy for 94 compounds. Aromatics, alkanes and terpenes were the major compound groups detected. Most VOCs had mean concentrations below 5 µg/m3, and most indoor/outdoor concentration ratios ranged from one to 10. For 16 VOCs, the within-school variance of concentrations exceeded that between schools and, overall, no major differences in VOC concentrations were found between conventional and high performance buildings. While VOC concentrations have declined from levels measured in earlier decades, opportunities remain to improve indoor air quality (IAQ) by limiting emissions from building-related sources and by increasing ventilation rates. PMID:28117727
Changes to indoor air quality as a result of relocating families from slums to public housing
NASA Astrophysics Data System (ADS)
Burgos, Soledad; Ruiz, Pablo; Koifman, Rosalina
2013-05-01
One largely unstudied benefit of relocating families from slums to public housing is the potential improvement in indoor air quality (IAQ). We compared families that moved from slums to public housing with those that remained living in slums in Santiago, Chile in terms of fine particulate matter (PM2.5) as main indicator of change. A cross-sectional study of 98 relocated families and 71 still living in slums was carried out, obtaining indoor and outdoor samples by a Personal Environmental Monitor. Home characteristics, including indoor air pollution sources were collected through questionnaires. Multivariate regression models included the intervention (public housing or slum), indoor pollution sources, outdoor PM2.5 and family characteristics as predictors. Indoor PM2.5 concentrations were higher in slums (77.8 μg m-3 [SD = 35.7 μg m-3]) than in public housing (55.7 μg m-3 [SD = 34.6 μg m-3], p < 0.001). Differences between indoor and outdoor PM2.5 were significant only in the slum houses. The multivariate analysis showed that housing intervention significantly decreased indoor PM2.5 (10.4 μg m-3) after adjusting by the other predictors. Outdoor PM2.5 was the main predictor of indoor PM2.5. Other significant factors were water heating fuels and indoor smoking. Having infants 1-23 months was associated with a lowering of indoor PM2.5. Our results suggest that a public housing program that moves families from slums to public housing improves indoor air quality directly and also indirectly through air pollution sources.
Oh, TaeSeok; Kim, MinJeong; Lim, JungJin; Kang, OnYu; Shetty, K Vidya; SankaraRao, B; Yoo, ChangKyoo; Park, Jae Hyung; Kim, Jeong Tai
2012-05-01
Subway systems are considered as main public transportation facility in developed countries. Time spent by people in indoors, such as underground spaces, subway stations, and indoor buildings, has gradually increased in the recent past. Especially, operators or old persons who stay in indoor environments more than 15 hr per day usually influenced a greater extent by indoor air pollutants. Hence, regulations on indoor air pollutants are needed to ensure good health of people. Therefore, in this study, a new cumulative calculation method for the estimation of total amounts of indoor air pollutants emitted inside the subway station is proposed by taking cumulative amounts of indoor air pollutants based on integration concept. Minimum concentration of individual air pollutants which naturally exist in indoor space is referred as base concentration of air pollutants and can be found from the data collected. After subtracting the value of base concentration from data point of each data set of indoor air pollutant, the primary quantity of emitted air pollutant is calculated. After integration is carried out with these values, adding the base concentration to the integration quantity gives the total amount of indoor air pollutant emitted. Moreover the values of new index for cumulative indoor air quality obtained for 1 day are calculated using the values of cumulative air quality index (CAI). Cumulative comprehensive indoor air quality index (CCIAI) is also proposed to compare the values of cumulative concentrations of indoor air pollutants. From the results, it is clear that the cumulative assessment approach of indoor air quality (IAQ) is useful for monitoring the values of total amounts of indoor air pollutants emitted, in case of exposure to indoor air pollutants for a long time. Also, the values of CCIAI are influenced more by the values of concentration of NO2, which is released due to the use of air conditioners and combustion of the fuel. The results obtained in this study confirm that the proposed method can be applied to monitor total amounts of indoor air pollutants emitted, inside apartments and hospitals as well. Nowadays, subway systems are considered as main public transportation facility in developed countries. Time spent by people in indoors, such as underground spaces, subway stations, and indoor buildings, has gradually increased in the recent past. Especially, operators or old persons who stay in the indoor environments more than 15 hr per day usually influenced a greater extent by indoor air pollutants. Hence, regulations on indoor air pollutants are needed to ensure good health of people. Therefore, this paper presents a new methodology for monitoring and assessing total amounts of indoor air pollutants emitted inside underground spaces and subway stations. A new methodology for the calculation of cumulative amounts of indoor air pollutants based on integration concept is proposed. The results suggest that the cumulative assessment approach of IAQ is useful for monitoring the values of total amounts of indoor air pollutants, if indoor air pollutants accumulated for a long time, especially NO2 pollutants. The results obtained here confirm that the proposed method can be applied to monitor total amounts of indoor air pollutants emitted, inside apartments and hospitals as well.
McConnell AFB, Kansas Revised Uniform Summary of Surface Weather Observations (RUSSWO). Parts A-F.
1987-04-07
OBSERVATIONS MCCONNELL AFB KS MSC f724505 N 37 37 W 097 lb ELEV 1371 FT KIAB PARTS A - F HOURS SUMMARIZED: 0000 - 230u LST PERIOD OF RECORD: HOURLY...the world. This is the provenance of the number (e.g., MSC 999999) which will appear on future OL-A standard products. NTIS ,.& - DCIC IAQ . y...STATICN NUMqLR: 724505 STAIION NAME: MCCONNELL AFR KS PEO0 UF [ COPD : 60-P6 ..... .......... °.. . ...... ....... .. .. .. .... . ,.... o
NASA Astrophysics Data System (ADS)
Hwang, Sung Ho; Yoon, Chung Sik; Ryu, Kyong Nam; Paik, Samuel Y.; Cho, Jun Ho
2010-05-01
This study assessed bacterial concentrations in indoor air at 25 underground railway stations in Seoul, Korea, and investigated various related factors including the presence of platform screen doors (PSD), depth of the station, year of construction, temperature, relative humidity, and number of passengers. A total of 72 aerosol samples were collected from all the stations. Concentrations of total airborne bacteria (TAB) ranged from not detected (ND) to 4997 CFU m -3, with an overall geometric mean (GM) of 191 CFU m -3. Airborne bacteria were detected at 23 stations (92%) and Gram-negative bacteria (GNB) were detected at two stations (8%). TAB concentrations of four stations (16%) exceeded 800 CFU m -3, the Korea indoor bio-aerosol guideline. The results of the study showed that TAB concentrations at the stations without PSD showed higher TAB concentrations than those with PSD, though not at statistically significant levels. TAB concentrations of deeper stations revealed significantly higher levels than those of shallower stations. Based on this study, it is recommended that mitigation measures be applied to improve the indoor air quality (IAQ) of underground railway stations in Seoul, with focused attention on deeper stations.
NASA Astrophysics Data System (ADS)
Mancini, S.; Caliendo, E.; Guida, M.; Bisceglia, B.
2017-10-01
The main purpose of the work described in this paper has been to establish the protocol for a new non-disruptive technique of intervention, based on microwave treatment, for cleaning operations on monumental historical buildings, to eliminate biodeteriogens infesting stones. Non-destructive methods in the cleaning operations, should not only preserve the physical integrity, the chemical-mineralogical and structural identity of materials, but, when the exhalation of pollutant agents (like for example Radon gas) from building materials is considered, also, make the indoor air quality (IAQ) levels healthy. Therefore, one of the main steps of the protocol proposed in this paper is concerned with the assessment of the Radon exhalation rate in order to verify that microwave treatments do not increase the Radon naturally exhalated by building materials. In this paper, the preliminary results of the Radon measurements performed on two different type of tuff samples (grey tuff and yellow tuff), typical of the Italian traditional construction heritage, with the E-PERM passive technique at the Environmental Radioactivity Laboratory (Amb.Ra.), University of Salerno, Italy, ISO 9001:2008 certified, are summarized.
Indoor air quality in Latino homes in Boulder, Colorado
NASA Astrophysics Data System (ADS)
Escobedo, Luis E.; Champion, Wyatt M.; Li, Ning; Montoya, Lupita D.
2014-08-01
Indoor concentrations of airborne pollutants can be several times higher than those found outdoors, often due to poor ventilation, overcrowding, and the contribution of indoor sources within a home. Americans spend most of their time indoors where exposure to poor indoor air quality (IAQ) can result in diminished respiratory and cardiovascular health. This study measured the indoor air quality in 30 homes of a low-income Latino community in Boulder, Colorado during the summer of 2012. Participants were administered a survey, which included questions on their health conditions and indoor air pollution sources like cigarette smoke, heating fuel, and building materials. Twenty-four hour samples of fine particulate matter (PM2.5) from the indoor air were collected in each home; ambient PM2.5 samples were collected each day as well. Concurrent air samples were collected onto 47 mm Teflo and Tissuquartz filter at each location. Teflo filters were analyzed gravimetrically to measure PM2.5 and their extracts were used to determine levels of proteins and endotoxins in the fine fraction. The Tissuquartz filters were analyzed for elemental and organic carbon content (EC/OC). Results indicated that the indoor air contained higher concentrations of PM2.5 than the ambient air, and that the levels of OC were much higher than EC in both indoor and outdoor samples. This community showed no smoking in their homes and kept furry pets indoors at very low rates; therefore, cooking is likely the primary source of indoor PM. For responders with significant exposure to PM, it appeared to be primarily from occupational environments or childhood exposure abroad. Our findings indicate that for immigrant communities such as this, it is important to consider not only their housing conditions but also the relevant prior exposures when conducting health assessments.
Microbiological assessment of indoor air quality at different hospital sites.
Cabo Verde, Sandra; Almeida, Susana Marta; Matos, João; Guerreiro, Duarte; Meneses, Marcia; Faria, Tiago; Botelho, Daniel; Santos, Mateus; Viegas, Carla
2015-09-01
Poor hospital indoor air quality (IAQ) may lead to hospital-acquired infections, sick hospital syndrome and various occupational hazards. Air-control measures are crucial for reducing dissemination of airborne biological particles in hospitals. The objective of this study was to perform a survey of bioaerosol quality in different sites in a Portuguese Hospital, namely the operating theater (OT), the emergency service (ES) and the surgical ward (SW). Aerobic mesophilic bacterial counts (BCs) and fungal load (FL) were assessed by impaction directly onto tryptic soy agar and malt extract agar supplemented with antibiotic chloramphenicol (0.05%) plates, respectively using a MAS-100 air sampler. The ES revealed the highest airborne microbial concentrations (BC range 240-736 CFU/m(3) CFU/m(3); FL range 27-933 CFU/m(3)), exceeding, at several sampling sites, conformity criteria defined in national legislation [6]. Bacterial concentrations in the SW (BC range 99-495 CFU/m(3)) and the OT (BC range 12-170 CFU/m(3)) were under recommended criteria. While fungal levels were below 1 CFU/m(3) in the OT, in the SW (range 1-32 CFU/m(3)), there existed a site with fungal indoor concentrations higher than those detected outdoors. Airborne Gram-positive cocci were the most frequent phenotype (88%) detected from the measured bacterial population in all indoor environments. Staphylococcus (51%) and Micrococcus (37%) were dominant among the bacterial genera identified in the present study. Concerning indoor fungal characterization, the prevalent genera were Penicillium (41%) and Aspergillus (24%). Regular monitoring is essential for assessing air control efficiency and for detecting irregular introduction of airborne particles via clothing of visitors and medical staff or carriage by personal and medical materials. Furthermore, microbiological survey data should be used to clearly define specific air quality guidelines for controlled environments in hospital settings. Copyright © 2015 Institut Pasteur. Published by Elsevier Masson SAS. All rights reserved.
Quansah, Reginald; Semple, Sean; Ochieng, Caroline A; Juvekar, Sanjar; Armah, Frederick Ato; Luginaah, Isaac; Emina, Jacques
2017-06-01
Cookstove intervention programs have been increasing over the past two (2) decades in Low and Middle Income Countries (LMICs) across the globe. However, there remains uncertainty regarding the effects of these interventions on household air pollution concentrations, personal exposure concentrations and health outcomes. The primary objective was to determine if household air pollution (HAP) interventions were associated with improved indoor air quality (IAQ) in households in LMICs. Given the potential impact of HAP interventions on health, a secondary objective was to evaluate the effectiveness of HAP interventions to improve health in populations receiving these interventions. OVID Medline, Ovid Embase, SCOPUS and PubMED were searched from their inception until December 2015 with no restrictions on study design. The WHO Global database of household air pollution measurements and Members' archives were also reviewed together with the reference lists of identified reviews and relevant articles. We considered randomized controlled trials, or non-randomized control trials, or before-and-after studies; original studies; studies conducted in a LMIC (based on the United Nations Human Development Report released in March 2013 (World Bank, 2013); interventions that were explicitly aimed at improving IAQ and/or health from solid fuel use; studies published in a peer-reviewed journal or student theses or reports; studies that reported on outcomes which was indicative of IAQ or/and health. There was no restriction on the type of comparator (e.g. household receiving plancha vs. household using traditional cookstove) used in the intervention study. Five review authors independently used pre-designed data collection forms to extract information from the original studies and assessed risk of bias using the Effective Public Health Practice Project (EPHPP). We computed standardized weighted mean difference (SMD) using random-effects models. Heterogeneity was computed using the Q and I2-statistics. We examined the influence of various characteristics on the study-specific effect estimates by stratifying the analysis by population type, study design, intervention type, and duration of exposure monitoring. The trim and fill method was used to assess the potential impact of missing studies. Fifty-five studies met our a priori inclusion criteria and were included in the systematic review. Fifteen studies provided 43 effect estimates for our meta-analysis. The largest improvement in HAP was observed for average particulate matter (PM) (SMD=1.57) concentrations in household kitchens (1.03), followed by daily personal average concentrations of PM (1.18), and carbon monoxide (CO) concentrations in kitchens. With respect to personal PM, significant improvement was observed in studies of children (1.26) and studies monitoring PM for ≥24h (1.32). This observation was also noted in terms of studies of kitchen concentrations of CO. A significant improvement was also observed for kitchen levels of PM in both adult populations (1.56) and in RCT/cohort designs (1.59) involving replacing cookstoves without chimneys. Our findings on health outcomes were inconclusive. We observed high statistical between study variability in the study-specific estimate. Thus, care should be taken in concluding that HAP interventions - as currently designed and implemented - support reductions in the average kitchen and personal levels of PM and CO. Further, there is limited evidence that current stand-alone HAP interventions yield any health benefits. Post-intervention levels of pollutants were generally still greatly in excess of the relevant WHO guideline and thus a need to promote cleaner fuels in LMICs to reduce HAP levels below the WHO guidelines. The review has been registered with PROSPERO (registration number CRD42014009768). Copyright © 2016. Published by Elsevier Ltd.
Impact of regulation on indoor volatile organic compounds in new unoccupied apartment in Korea
NASA Astrophysics Data System (ADS)
Lim, Soogil; Lee, Kiyoung; Seo, Sooyun; Jang, Seongki
2011-02-01
The Indoor Air Quality (IAQ) Control in Public Use Facilities Act in Korea, which came into effect on January 1, 2006, set standards of indoor environmental concentrations for benzene, toluene, ethylbenzene, xylenes, styrene, and formaldehyde. This study aimed to determine the impact of the Act on levels of volatile organic compounds (VOCs) and to identify factors associated with indoor VOCs levels. VOCs and formaldehyde levels were measured in 228 new, unoccupied apartments from 2005 to 2007. In 2005, the mean total VOC (TVOC) concentration in 108 unoccupied apartments was 1606 μg m -3. After 2006, mean TVOC concentration in 120 unoccupied apartments was 645 μg m -3, significantly lower than the 2005 level. In 2005, the percentages of apartments exceeding standards were 14% for xylenes, 5% for ethylbenzene, 3% for toluene, and 1% for formaldehyde. After 2006, no apartment exceeded standards. When other building characteristics were controlled, the concentrations of TVOC, toluene, ethylbenzene, xylenes, and formaldehyde after 2006 were significantly lower than 2005 levels. However, benzene and styrene levels did not change. The reduction in VOCs levels was significantly associated with flooring materials, adhesive, and paint. These findings demonstrate that regulation can reduce VOC concentrations in new apartments through the use of low-emission building materials.
1987-05-01
plvdl ’ , systems, Applied Optics, 16( 12), 1181 - iAQ. Champion, 7. ’., G . H . Meeten and ". enir, ’ " . , ’ particles in the colloidal state, ourna: ,f...he her, 4a London, Faraday Transactions * - Champion, J. V. , G . H . Meeten , 1. 4. U 0 1n and -arp. Optical extinction of randomly ,oriented in, T...distance into the (poly) dispersion. We can find T -from f du fdy fda G (u,y,$) Qi(u,y,S) n(u) g (y) h (B) (15) where u is some parameter specifying
Song, Gang; Wang, Xinming; Chen, Diyun; Chen, Yongheng
2011-04-01
This study investigates the contribution of radon ((222)Rn)-bearing water to indoor (222)Rn in thermal baths. The (222)Rn concentrations in air were monitored in the bathroom and the bedroom. Particulate matter (PM, both PM(10) and PM(2.5)) and carbon dioxide (CO(2)) were also monitored with portable analyzers. The bathrooms were supplied with hot spring water containing 66-260 kBq m(-3) of (222)Rn. The results show that the spray of hot spring water from the bath spouts is the dominant mechanism by which (222)Rn is released into the air of the bathroom, and then it diffuses into the bedroom. Average (222)Rn level was 110-410% higher in the bedrooms and 510-1200% higher in the bathrooms compared to the corresponding average levels when there was no use of hot spring water. The indoor (222)Rn levels were influenced by the (222)Rn concentrations in the hot spring water and the bathing times. The average (222)Rn transfer coefficients from water to air were 6.2 × 10(-4)-4.1 × 10(-3). The 24-h average levels of CO(2) and PM(10) in the hotel rooms were 89% and 22% higher than the present Indoor Air Quality (IAQ) standard of China. The main particle pollutant in the hotel rooms was PM(2.5). Radon and PM(10) levels in some hotel rooms were at much higher concentrations than guideline levels, and thus the potential health risks to tourists and especially to the hotel workers should be of great concern, and measures should be taken to lower inhalation exposure to these air pollutants. Copyright © 2011 Elsevier Ltd. All rights reserved.
Applying large datasets to developing a better understanding of air leakage measurement in homes
Walker, I. S.; Sherman, M. H.; Joh, J.; ...
2013-03-01
Air tightness is an important property of building envelopes. It is a key factor in determining infiltration and related wall-performance properties such as indoor air quality, maintainability and moisture balance. Air leakage in U.S. houses consumes roughly 1/3 of the HVAC energy but provides most of the ventilation used to control IAQ. There are several methods for measuring air tightness that may result in different values and sometimes quite different uncertainties. The two main approaches trade off bias and precision errors and thus result indifferent outcomes for accuracy and repeatability. To interpret results from the two approaches, various questions needmore » to be addressed, such as the need to measure the flow exponent, the need to make both pressurization and depressurization measurements and the role of wind in determining the accuracy and precision of the results. This article uses two large datasets of blower door measurements to reach the following conclusions. For most tests the pressure exponent should be measured but for wind speeds greater than 6 m/s a fixed pressure exponent reduces experimental error. The variability in reported pressure exponents is mostly due to changes in envelope leakage characteristics. Finally, it is preferable to test in both pressurization and depressurization modes due to significant differences between the results in these two modes.« less
Correlation between plant physiology and CO2 removable
NASA Astrophysics Data System (ADS)
Leman, A. M.; Shamsuri, Mohd Mahathir Suhaimi; Hariri, Azian; Kadir, Aeslina Abdul; Idris, Ahmad Fu'ad; Afandi, Azizi
2017-09-01
Certain plants that are able to live in the building are known as indoor plants. Plants have tolerance with indoor environment in order to survive. Usually these plants are able to improve indoor air quality (IAQ). Absorption of carbon dioxide (CO2) by plants is one of the indicators that plants are still alive during photosynthesis process. The possibility of plants structure (plant physiology) to affect CO2 absorption had been the concerns of former researchers. This research intends to study the significant of plant structure (leaf area, fresh weight, and dry weight) that leads to reducing the concentration of CO2 by seven plant species (Anthurium, Dumb Cane, Golden Pothos, Kadaka Fern, Prayer Plants, Spider Plants, and Syngonium). The data of CO2 reduction by plants has been obtained from previous studies. Based on results show that, the leaf area is the most contributing the significant effect to the plant absorb CO2 compare to fresh weight and dry weight. It can be prove by Pearson Correlation, where only the value of leaf area is more than 0.5 for every four conditions. This study can be conclude that the leaf area is quite plays an important role to the plant treat air from CO2, while concentration of light and CO2 will become catalytic factor for the plants improve their photosynthesis process.
Measurements of VOC adsorption/desorption characteristics of typical interior building materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
An, Y.; Zhang, J.S.; Shaw, C.Y.
2000-07-01
The adsorption/desorption of volatile organic compounds (VOCs) on interior building material surfaces (i.e., the sink effect) can affect the VOC concentrations in a building, and thus need to be accounted for an indoor air quality (IAQ) prediction model. In this study, the VOC adsorption/desorption characteristics (sink effect) were measured for four typical interior building materials including carpet, vinyl floor tile, painted drywall, and ceiling tile. The VOCs tested were ethylbenzene, cyclohexanone, 1,4-dichlorobenzene, benzaldehyde, and dodecane. These five VOCs were selected because they are representative of hydrocarbons, aromatics, ketones, aldehydes, and chlorine substituted compounds. The first order reversible adsorption/desorption model wasmore » based on the Langmuir isotherm was used to analyze the data and to determine the equilibrium constant of each VOC-material combination. It was found that the adsorption/desorption equilibrium constant, which is a measure of the sink capacity, increased linearly with the inverse of the VOC vapor pressure. For each compound, the adsorption/desorption equilibrium constant, and the adsorption rate constant differed significantly among the four materials tested. A detailed characterization of the material structure in the micro-scale would improve the understanding and modeling of the sink effect in the future. The results of this study can be used to estimate the impact of sink effect on the VOC concentrations in buildings.« less
Assessing the Quality of Problems in Problem-Based Learning
ERIC Educational Resources Information Center
Sockalingam, Nachamma; Rotgans, Jerome; Schmidt, Henk
2012-01-01
This study evaluated the construct validity and reliability of a newly devised 32-item problem quality rating scale intended to measure the quality of problems in problem-based learning. The rating scale measured the following five characteristics of problems: the extent to which the problem (1) leads to learning objectives, (2) is familiar, (3)…
Sharpe, Helen; Patalay, Praveetha; Fink, Elian; Vostanis, Panos; Deighton, Jessica; Wolpert, Miranda
2016-06-01
Quality of life is typically reduced in children with mental health problems. Understanding the relationship between quality of life and mental health problems and the factors that moderate this association is a pressing priority. This was a cross-sectional study involving 45,398 children aged 8-13 years from 880 schools in England. Self-reported quality of life was assessed using nine items from the KIDSCREEN-10 and mental health was assessed using the Me and My School Questionnaire. Demographic information (gender, age, ethnicity, socio-economic status) was also recorded. Quality of life was highest in children with no problems and lowest in children with both internalising and externalising problems. There was indication that quality of life may be reduced in children with internalising problems compared with externalising problems. Approximately 12 % children with mental health problems reported high quality of life. The link between mental health and quality of life was moderated by gender and age but not by socio-economic status or ethnicity. This study supports previous work showing mental health and quality of life are related but not synonymous. The findings have implications for measuring quality of life in child mental health settings and the need for approaches to support children with mental health problems that are at particular risk of poor quality of life.
Rios, José Luiz de Magalhães; Boechat, José Laerte; Gioda, Adriana; dos Santos, Celeste Yara; de Aquino Neto, Francisco Radler; Lapa e Silva, José Roberto
2009-11-01
An increasing number of complaints related to time spent in artificially ventilated buildings have been progressively reported and attributed, at least in part, to physical and chemical exposures in the office environment. The objective of this research was to investigate the association between the prevalence of work-related symptoms and the indoor air quality, comparing a sealed office building with a naturally ventilated one, considering, specially, the indoor concentration of TPM, TVOCs and the main individual VOCs. A cross-sectional study was performed to compare the prevalence of sick building syndrome (SBS) symptoms among 1736 office workers of a sealed office building and 950 of a non-sealed one, both in Rio de Janeiro's downtown. The prevalence of symptoms was obtained by a SBS standardized questionnaire. The IAQ of the buildings was evaluated through specific methods, to determine the temperature, humidity, particulate matter and volatile organic compound (VOC) concentrations. Upper airways and ophthalmic symptoms, tiredness and headache were highly prevalent in both buildings. Some symptoms were more prevalent in the sealed building: "eye dryness" 33.3% and 27.1% (p: 0.01); "runny nose" 37.3% and 31.3% (p: 0.03); "dry throat" 42% and 36% (p: 0.02); and "lethargy" 58.5% and 50.5% (p: 0.03) respectively. However, relative humidity and indoor total particulate matter (TPM) concentration as well as total volatile organic compounds (TVOCs) were paradoxically greater in the non-sealed building, in which aromatic compounds had higher concentration, especially benzene. The analysis between measured exposure levels and resulting symptoms showed no association among its prevalence and TPM, TVOCs, benzene or toluene concentration in none of the buildings. Other disregarded factors, like undetected VOCs, mites, molds and endotoxin concentrations, may be associated to the greater prevalence of symptoms in the sealed building.
Minimum airflow reset of single-duct VAV terminal boxes
NASA Astrophysics Data System (ADS)
Cho, Young-Hum
Single duct Variable Air Volume (VAV) systems are currently the most widely used type of HVAC system in the United States. When installing such a system, it is critical to determine the minimum airflow set point of the terminal box, as an optimally selected set point will improve the level of thermal comfort and indoor air quality (IAQ) while at the same time lower overall energy costs. In principle, this minimum rate should be calculated according to the minimum ventilation requirement based on ASHRAE standard 62.1 and maximum heating load of the zone. Several factors must be carefully considered when calculating this minimum rate. Terminal boxes with conventional control sequences may result in occupant discomfort and energy waste. If the minimum rate of airflow is set too high, the AHUs will consume excess fan power, and the terminal boxes may cause significant simultaneous room heating and cooling. At the same time, a rate that is too low will result in poor air circulation and indoor air quality in the air-conditioned space. Currently, many scholars are investigating how to change the algorithm of the advanced VAV terminal box controller without retrofitting. Some of these controllers have been found to effectively improve thermal comfort, indoor air quality, and energy efficiency. However, minimum airflow set points have not yet been identified, nor has controller performance been verified in confirmed studies. In this study, control algorithms were developed that automatically identify and reset terminal box minimum airflow set points, thereby improving indoor air quality and thermal comfort levels, and reducing the overall rate of energy consumption. A theoretical analysis of the optimal minimum airflow and discharge air temperature was performed to identify the potential energy benefits of resetting the terminal box minimum airflow set points. Applicable control algorithms for calculating the ideal values for the minimum airflow reset were developed and applied to actual systems for performance validation. The results of the theoretical analysis, numeric simulations, and experiments show that the optimal control algorithms can automatically identify the minimum rate of heating airflow under actual working conditions. Improved control helps to stabilize room air temperatures. The vertical difference in the room air temperature was lower than the comfort value. Measurements of room CO2 levels indicate that when the minimum airflow set point was reduced it did not adversely affect the indoor air quality. According to the measured energy results, optimal control algorithms give a lower rate of reheating energy consumption than conventional controls.
Collaborative problem solving with a total quality model.
Volden, C M; Monnig, R
1993-01-01
A collaborative problem-solving system committed to the interests of those involved complies with the teachings of the total quality management movement in health care. Deming espoused that any quality system must become an integral part of routine activities. A process that is used consistently in dealing with problems, issues, or conflicts provides a mechanism for accomplishing total quality improvement. The collaborative problem-solving process described here results in quality decision-making. This model incorporates Ishikawa's cause-and-effect (fishbone) diagram, Moore's key causes of conflict, and the steps of the University of North Dakota Conflict Resolution Center's collaborative problem solving model.
I/O values for determination of the origin of some indoor organic pollutants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Otson, R.; Zhu, J.
To reduce human health risks resulting from exposure to toxic chemicals, it is important to determine the origin of such substances. The ratio (I/O) of indoor to outdoor concentrations of selected airborne vapor phase organic compounds (VPOC) was used to estimate the contribution of indoor sources to levels of the compounds in the air of 44 homes selected randomly in the Greater Toronto Area (GTA). Average I/O values for all of the homes were greater 1.5 for 10 of the 20 detected target compounds, and it could be concluded that indoor VPOC sources had a greater impact on indoor airmore » quality than outdoor air in these instances. A significant finding, which aptly demonstrates the importance of indoor sources and pollution, was the overall I/O value of 5.2 for the 44 representative GTA homes. Possible indoor sources for most of the 10 compounds could be identified, based on information collected by means of a questionnaire, as well as from the scientific literature. However, possible sources for some compounds could not be determined as readily, probably because of the presence of multiple sources, and sources which had not been previously noted, such as foods and beverages. The sensitivity of I/O values to various factors (e.g., source strength, air exchange rates, precision of measurements, unanticipated sources), and the reliability of determining the origin of pollutants by use of I/O values alone were examined, with some examples. If used judiciously, the I/O value can be a useful tool for IAQ investigations.« less
Controlling Indoor Air Pollution from Moxibustion
Lu, Chung-Yen; Kang, Sy-Yuan; Liu, Shu-Hui; Mai, Cheng-Wei; Tseng, Chao-Heng
2016-01-01
Indoor air quality (IAQ) control of hospitals plays a critical role in protecting both hospital staffs and patients, particularly those who are highly susceptible to the adverse effects of indoor noxious hazards. However, moxibustion in outpatient departments (OPDs) of traditional Chinese medicine (TCM) may be a source of indoor air pollution in hospitals. Some studies have investigated indoor air pollution during moxibustion in Chinese medicine clinics (CMCs) and moxibustion rooms, demonstrating elevated air pollutants that pose a threat to the health of medical staff and patients. Our study investigated the indoor air pollutants of indoor carbon dioxide (CO2), carbon monoxide (CO), formaldehyde (HCHO), total volatile organic compounds (TVOCs), airborne particulate matter with a diameter of ≤10 µm (PM10) and ≤2.5 µm (PM2.5) during moxibustion in an acupuncture and moxibustion room of the OPD in a hospital in Taipei. To evaluate the different control strategies for indoor air pollution from moxibution, a comparison of air pollutants during moxibution among the methods of using alternative old moxa wools, local exhaust ventilation and an air cleaner was conducted. In this study, burning alternative old moxa wools for moxibustion obviously reduced all gaseous pollutants except for aerosols comparing burning fresh moxa wools. Using local exhaust ventilation reduced most of the aerosols after burning moxa. We also found that using an air cleaner was inefficient for controlling indoor air pollutants, particularly gaseous pollutants. Therefore, combining replacing alternative old moxa wools and local exhaust ventilation could be a suitable design for controlling indoor air pollution during moxibustion therapy. PMID:27331817
Controlling Indoor Air Pollution from Moxibustion.
Lu, Chung-Yen; Kang, Sy-Yuan; Liu, Shu-Hui; Mai, Cheng-Wei; Tseng, Chao-Heng
2016-06-20
Indoor air quality (IAQ) control of hospitals plays a critical role in protecting both hospital staffs and patients, particularly those who are highly susceptible to the adverse effects of indoor noxious hazards. However, moxibustion in outpatient departments (OPDs) of traditional Chinese medicine (TCM) may be a source of indoor air pollution in hospitals. Some studies have investigated indoor air pollution during moxibustion in Chinese medicine clinics (CMCs) and moxibustion rooms, demonstrating elevated air pollutants that pose a threat to the health of medical staff and patients. Our study investigated the indoor air pollutants of indoor carbon dioxide (CO₂), carbon monoxide (CO), formaldehyde (HCHO), total volatile organic compounds (TVOCs), airborne particulate matter with a diameter of ≤10 µm (PM10) and ≤2.5 µm (PM2.5) during moxibustion in an acupuncture and moxibustion room of the OPD in a hospital in Taipei. To evaluate the different control strategies for indoor air pollution from moxibution, a comparison of air pollutants during moxibution among the methods of using alternative old moxa wools, local exhaust ventilation and an air cleaner was conducted. In this study, burning alternative old moxa wools for moxibustion obviously reduced all gaseous pollutants except for aerosols comparing burning fresh moxa wools. Using local exhaust ventilation reduced most of the aerosols after burning moxa. We also found that using an air cleaner was inefficient for controlling indoor air pollutants, particularly gaseous pollutants. Therefore, combining replacing alternative old moxa wools and local exhaust ventilation could be a suitable design for controlling indoor air pollution during moxibustion therapy.
Hwang, Gi Byoung; Lee, Jung Eun; Nho, Chu Won; Lee, Byung Uk; Lee, Seung Jae; Jung, Jae Hee; Bae, Gwi-Nam
2012-04-01
Bioaerosols have received social and scientific attention because they can be hazardous to human health. Recently, antimicrobial treatments using natural products have been used to improve indoor air quality (IAQ) since they are typically less toxic to humans compared to other antimicrobial substances such as silver, carbon nanotubes, and metal oxides. Few studies, however, have examined how environmental conditions such as the relative humidity (RH), surrounding temperature, and retention time of bacteria on filters affect the filtration and antimicrobial characteristics of a filter treated with such natural products. In this study, we investigated changes in the morphology of the natural nanoparticles, pressure drop, filtration efficiency, and the inactivation rate caused by the short-term effect of humid airflow on antimicrobial fiber filters. Nanoparticles of Sophora flavescens were deposited on the filter media surface using an aerosol process. We observed coalescence and morphological changes of the nanoparticles on fiber filters under humid conditions of an RH >50%. The level of coalescence in these nanoparticles increased with increasing RH. Filters exposed to an RH of 25% have a higher pressure drop than those exposed to an RH >50%. In an inactivation test against Staphylococcus epidermidis bacterial aerosol, the inactivation efficiency at an RH of 25% was higher than that at an RH of 57% or 82%. To effectively apply antimicrobial filters using natural products in the environment, one must characterize the filters under various environmental conditions. Thus, this study provides important information on the use of antimicrobial filters made of natural products. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Ren, Jianlin; Cao, Xiaodong; Liu, Junjie
2018-04-01
Passengers usually spend hours in the airport terminal buildings waiting for their departure. During the long waiting period, ambient fine particles (PM2.5) and ultrafine particles (UFP) generated by airliners may penetrate into terminal buildings through open doors and the HVAC system. However, limited data are available on passenger exposure to particulate pollutants in terminal buildings. We conducted on-site measurements on PM2.5 and UFP concentration and the particle size distribution in the terminal building of Tianjin Airport, China during three different seasons. The results showed that the PM2.5 concentrations in the terminal building were considerably larger than the values guided by Chinese standard and WHO on all of the tested seasons, and the conditions were significantly affected by the outdoor air (Spearman test, p < 0.01). The indoor/outdoor PM2.5 ratios (I/O) ranged from 0.67 to 0.84 in the arrival hall and 0.79 to 0.96 in the departure hall. The particle number concentration in the terminal building presented a bi-modal size distribution, with one mode being at 30 nm and another mode at 100 nm. These results were totally different from the size distribution measured in a normal urban environment. The total UFP exposure during the whole waiting period (including in the terminal building and airliner cabin) of a passenger is approximately equivalent to 11 h of exposure to normal urban environments. This study is expected to contribute to the improvement of indoor air quality and health of passengers in airport terminal buildings.
Emotional Problems, Quality of Life, and Symptom Burden in Patients With Lung Cancer.
Morrison, Eleshia J; Novotny, Paul J; Sloan, Jeff A; Yang, Ping; Patten, Christi A; Ruddy, Kathryn J; Clark, Matthew M
2017-09-01
Lung cancer is associated with a greater symptom burden than other cancers, yet little is known about the prevalence of emotional problems and how emotional problems may be related to the physical symptom burden and quality of life in newly diagnosed patients with lung cancer. This study aimed to identify the patient and disease characteristics of patients with lung cancer experiencing emotional problems and to examine how emotional problems relate to quality of life and symptom burden. A total of 2205 newly diagnosed patients with lung cancer completed questionnaires on emotional problems, quality of life, and symptom burden. Emotional problems at diagnosis were associated with younger age, female gender, current cigarette smoking, current employment, advanced lung cancer disease, surgical or chemotherapy treatment, and a lower Eastern Cooperative Oncology Group performance score. Additionally, strong associations were found between greater severity of emotional problems, lower quality of life, and greater symptom burden. Certain characteristics place patients with lung cancer at greater risk for emotional problems, which are associated with a reduced quality of life and greater symptom burden. Assessment of the presence of emotional problems at the time of lung cancer diagnosis provides the opportunity to offer tailored strategies for managing negative mood, and for improving the quality of life and symptom burden management of patients with lung cancer. Copyright © 2017 Elsevier Inc. All rights reserved.
Understanding Adult Age Differences in the Frequency of Problems With Friends.
Schlosnagle, Leo; Strough, JoNell
2017-01-01
We investigated characteristics of younger and older adults' friendships. Younger (N = 39) and older (N = 39) adults completed measures pertaining to a specific friend they had (i.e., contact frequency, positive friendship quality, and negative friendship quality) and their frequency of problems with friends in general. Older adults reported fewer problems with friends in general, and fewer negative friendship qualities, less frequent contact, and more positive friendship qualities with a specific friend than younger adults. Contact frequency, positive friendship quality, and negative friendship quality with a specific friend were related to frequency of problems with friends in general, but only contact frequency was a significant mediator of the relation between age and frequency of problems with friends in general. Results show that characteristics of a specific friendship relate to problems with friends in general, and that contact frequency with a specific friend mediates the relation between age and problems with friends in general. Implications are discussed. © The Author(s) 2016.
Improving the quality of mass produced maps
Simley, J.
2001-01-01
Quality is critical in cartography because key decisions are often made based on the information the map communicates. The mass production of digital cartographic information to support geographic information science has now added a new dimension to the problem of cartographic quality, as problems once limited to small volumes can now proliferate in mass production programs. These problems can also affect the economics of map production by diverting a sizeable portion of production cost to pay for rework on maps with poor quality. Such problems are common to general industry-in response, the quality engineering profession has developed a number of successful methods to overcome these problems. Two important methods are the reduction of error through statistical analysis and addressing the quality environment in which people work. Once initial and obvious quality problems have been solved, outside influences periodically appear that cause adverse variations in quality and consequently increase production costs. Such errors can be difficult to detect before the customer is affected. However, a number of statistical techniques can be employed to detect variation so that the problem is eliminated before significant damage is caused. Additionally, the environment in which the workforce operates must be conductive to quality. Managers have a powerful responsibility to create this environment. Two sets of guidelines, known as Deming's Fourteen Points and ISO-9000, provide models for this environment.
Improving data quality in the linked open data: a survey
NASA Astrophysics Data System (ADS)
Hadhiatma, A.
2018-03-01
The Linked Open Data (LOD) is “web of data”, a different paradigm from “web of document” commonly used today. However, the huge LOD still suffers from data quality problems such as completeness, consistency, and accuracy. Data quality problems relate to designing effective methods both to manage and to retrieve information at various data quality levels. Based on review from papers and journals, addressing data quality requires some standards functioning to (1) identification of data quality problems, (2) assessment of data quality for a given context, and (3) correction of data quality problems. However, mostly the methods and strategies dealing with the LOD data quality were not as an integrative approach. Hence, based on those standards and an integrative approach, there are opportunities to improve the LOD data quality in the term of incompleteness, inaccuracy and inconsistency, considering to its schema and ontology, namely ontology refinement. Moreover, the term of the ontology refinement means that it copes not only to improve data quality but also to enrich the LOD. Therefore, it needs (1) a standard for data quality assessment and evaluation which is more appropriate to the LOD; (2) a framework of methods based on statistical relational learning that can improve the correction of data quality problems as well as enrich the LOD.
Problem of quality assurance during metal constructions welding via robotic technological complexes
NASA Astrophysics Data System (ADS)
Fominykh, D. S.; Rezchikov, A. F.; Kushnikov, V. A.; Ivashchenko, V. A.; Bogomolov, A. S.; Filimonyuk, L. Yu; Dolinina, O. N.; Kushnikov, O. V.; Shulga, T. E.; Tverdokhlebov, V. A.
2018-05-01
The problem of minimizing the probability for critical combinations of events that lead to a loss in welding quality via robotic process automation is examined. The problem is formulated, models and algorithms for its solution are developed. The problem is solved by minimizing the criterion characterizing the losses caused by defective products. Solving the problem may enhance the quality and accuracy of operations performed and reduce the losses caused by defective product
Buist, Kirsten L; Paalman, Carmen H; Branje, Susan J T; Deković, Maja; Reitz, Ellen; Verhoeven, Marjolein; Meeus, Wim H J; Koot, Hans M; Hale, William W
2014-04-01
The aim of the present study was to examine whether adolescents of Moroccan and Dutch origin differ concerning sibling relationship quality and to examine whether the associations between quality of the sibling relationship and level and change in externalizing and internalizing problem behavior are comparable for Moroccan and Dutch adolescents. Five annual waves of questionnaire data on sibling support and conflict as well as externalizing problems, anxiety and depression were collected from 159 ethnic Moroccan adolescents (Mage = 13.3 years) and from 159 ethnic Dutch adolescents (Mage = 13.0 years). Our findings demonstrated significant mean level differences between the Moroccan and Dutch sample in sibling relationship quality, externalizing problems, and depression, with Moroccan adolescents reporting higher sibling relationship quality and less problem behavior. However, effects of sibling relationship quality on externalizing problems, anxiety, and depression were similar for the Moroccan and Dutch samples. Sibling support was not related to level of externalizing problems, nor to changes in externalizing problems, anxiety, and depression. Additionally, more sibling conflict was related to a higher starting level of and faster decreases in problem behaviors. Our results support the ethnic equivalence model, which holds that the influence of family relationships is similar for different ethnic groups. Moreover, sibling support and conflict affect both the level and the fluctuations in problem behavior over time in specific ethnic groups similarly. Implications for future studies and interventions are subsequently discussed.
Bravo, Adrian J; Kelley, Michelle L; Hollis, Brittany F
2017-10-01
This study examined how work stressors were associated with sleep quality and alcohol-related problems among U.S. Navy members over the course of deployment. Participants were 101 U.S. Navy members assigned to an Arleigh Burke-class destroyer who experienced an 8-month deployment after Operational Enduring Freedom/Operation Iraqi Freedom. Approximately 6 weeks prior to deployment, 6 weeks after deployment, and 6 months reintegration, participants completed measures that assessed work stressors, sleep quality, and alcohol-related problems. A piecewise latent growth model was conducted in which the structural paths assessed if work stressors influenced sleep quality or its growth over time, and in turn if sleep quality influenced alcohol-related problems intercepts or growth over time. A significant indirect effect was found such that increases in work stressors from pre- to postdeployment predicted decreases in sleep quality, which in turn were associated with increases in alcohol-related problems from pre- to postdeployment. These effects were maintained from postdeployment through the 6-month reintegration. Findings suggest that work stressors may have important implications for sleep quality and alcohol-related problems. Positive methods of addressing stress and techniques to improve sleep quality are needed as both may be associated with alcohol-related problems among current Navy members. Copyright © 2016 John Wiley & Sons, Ltd.
The effect of proximity to major roads on indoor air quality in typical Australian dwellings
NASA Astrophysics Data System (ADS)
Lawson, Sarah J.; Galbally, Ian E.; Powell, Jennifer C.; Keywood, Melita D.; Molloy, Suzie B.; Cheng, Min; Selleck, Paul W.
2011-04-01
An Indoor Air Quality Study of residential dwellings was carried out in Melbourne, Australia, and a subset of the data was analysed to investigate the effect of proximity to major roads on indoor air quality (IAQ). Seven-day measurements of PM 10, NO 2, benzene, toluene, ethylbenzene and xylenes, along with continuous CO and PM 2.5 measurements were utilised. The measurements were made indoors and outdoors in 27 dwellings; 15 Near Road (<50 m from a major road) and 12 Far Road (>300 m from a major road). Dwellings were sampled for one week each in Winter/Spring 2008 and Summer/Autumn 2009, over an eight month period. Analysis of 7-day measurements showed that NO 2 and toluene were elevated at the 5% significance level both indoors and outdoors at Near Road Dwellings compared to Far Road Dwellings. Indoor/Outdoor (I/O) ratios of NO 2 and toluene were not significantly different between Near and Far Road dwellings giving no evidence of any anomalous dominant indoor source for NO 2 and toluene in Near Road dwellings. Indoor NO 2 was significantly correlated to gas stovetop and oven use in both Near and Far Road dwellings. In the absence of gas cooking, indoor NO 2 was elevated in Near Road dwellings relative to Far Road dwellings by approximately 4 ppb and this can be attributed to infiltration of outdoor air. I/O ratios for NO 2 were <1 for Near and Far Road dwellings, indicating that outdoor NO 2, and hence roadway emissions can potentially contribute a significant proportion to the indoor NO 2 concentration. Mean toluene I/O ratios were >2 indicating that indoor sources dominate with minor contribution from outdoors. Hence the relative contribution of roadways to indoor NO 2 is potentially greater than the relative contribution of roadways to indoor toluene. Findings elsewhere suggest that a similar outdoor enhancement of traffic related NO 2 (˜5 ppb) increases risk of lung cancer and childhood asthma ( Brauer et al., 2000; Nyberg et al., 2000). A simple conceptual model indicated spatial and temporal variance in the concentrations was the biggest limitation in detecting roadway influence outside Near Road dwellings for PM 10, PM 2.5 and NO 2 while measurement uncertainty was also important for CO.
Indoor air quality: A psychosocial perspective
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boxer, P.A.
1990-05-01
The incidence of indoor air quality problems has increased dramatically over the past decade. Investigation of these problems has yielded a definitive cause in only one third of the cases. Psychosocial factors may play a key role in the development and propagation of symptoms attributed to poor indoor air quality. Guidelines for managing indoor air quality problems from the organizational perspective are based upon psychosocial principles and elements of risk perception.
Prevalence of mood and sleep problems in chronic skin diseases: a pilot study.
Mostaghimi, Ladan
2008-05-01
The relationship between chronic skin problems and mood and sleep disorders merits more attention. Mood and sleep problems add to comorbidity of chronic skin diseases and affect patient compliance with dermatologic treatment. A pilot study was conducted to determine the prevalence of mood and sleep problems in participants with chronic skin diseases in outpatient dermatology clinics at the University of Wisconsin, Madison, using 4 self-assessment questionnaires. Study participants included willing adults with any skin problem of at least 6 months' duration. The participants were asked to complete the questionnaires, which included Current Life Functioning, Pittsburgh Sleep Quality Index (PSQI), Beck Depression Inventory (BDI-II), and Beck Anxiety Inventory. In summary, 15 of 16 participants had poor sleep quality. Six participants had poor sleep quality without any mood problems (depression or anxiety). Mood problems worsened the quality of sleep and functioning. Nine of 16 participants (56.25%) reported mood problems (depression or anxiety). The results show a high prevalence of depression and anxiety and a very high prevalence of poor sleep quality. Considering the negative effect of comorbid psychiatric and sleep problems on treatment and prognosis of chronic skin diseases, this study demonstrates the need for further evaluation and eventual screening of all patients with chronic skin diseases for mood and sleep problems.
Perceptions of Neighborhood Problems and Health-Related Quality of Life
ERIC Educational Resources Information Center
Hill, Erin M.; Shepherd, Daniel; Welch, David; Dirks, Kim N.; McBride, David
2012-01-01
This article examines the association between perceptions of neighborhood problems and health-related quality of life (HRQOL) in a sample of New Zealand residents (n = 692). A modified version of the Neighborhood Problems Scale (originally developed by Steptoe and Feldman, 2001) and the World Health Organization Quality of Life (WHOQOL-BREF) were…
Dharmalingam, Rajasekaran; Dash, Subhransu Sekhar; Senthilnathan, Karthikrajan; Mayilvaganan, Arun Bhaskar; Chinnamuthu, Subramani
2014-01-01
This paper deals with the performance of unified power quality conditioner (UPQC) based on current source converter (CSC) topology. UPQC is used to mitigate the power quality problems like harmonics and sag. The shunt and series active filter performs the simultaneous elimination of current and voltage problems. The power fed is linked through common DC link and maintains constant real power exchange. The DC link is connected through the reactor. The real power supply is given by the photovoltaic system for the compensation of power quality problems. The reference current and voltage generation for shunt and series converter is based on phase locked loop and synchronous reference frame theory. The proposed UPQC-CSC design has superior performance for mitigating the power quality problems. PMID:25013854
Dharmalingam, Rajasekaran; Dash, Subhransu Sekhar; Senthilnathan, Karthikrajan; Mayilvaganan, Arun Bhaskar; Chinnamuthu, Subramani
2014-01-01
This paper deals with the performance of unified power quality conditioner (UPQC) based on current source converter (CSC) topology. UPQC is used to mitigate the power quality problems like harmonics and sag. The shunt and series active filter performs the simultaneous elimination of current and voltage problems. The power fed is linked through common DC link and maintains constant real power exchange. The DC link is connected through the reactor. The real power supply is given by the photovoltaic system for the compensation of power quality problems. The reference current and voltage generation for shunt and series converter is based on phase locked loop and synchronous reference frame theory. The proposed UPQC-CSC design has superior performance for mitigating the power quality problems.
Desiccant-assisted air conditioner improves IAQ and comfort
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meckler, M.
1994-10-01
This article describes a system which offers the advantage of downsizing the evaporator coil and condensing unit capacities for comparable design loads, which in turn provides numerous benefits. Airborne microorganisms, which are responsible for many acute diseases, infections, and allergies, are well protected indoors by the moisture surrounding them. While the human body is generally the host for various bacteria and viruses, fungi can grow in moist places. It has been concluded that an optimum relative humidity (RH) range of 40 to 60 percent is necessary to minimize or eliminate the bacterial, viral, and fungal growth. In addition, humidity alsomore » has an effect on air cleanliness--it reduces the presence of dust particles--and on the deterioration of the building structure and its contents. Therefore, controlling humidity is a very important factor to human comfort in minimizing adverse health effects and maximizing the structural longevity of the building.« less
Reducing indoor air pollutants with air filtration units in wood stove homes.
McNamara, Marcy L; Thornburg, Jonathon; Semmens, Erin O; Ward, Tony J; Noonan, Curtis W
2017-08-15
Biomass burning has been shown to be a major source of poor indoor air quality (IAQ) in developing and higher income countries across the world. Specifically, wood burning for cooking and heating contributes to high indoor concentrations of fine (particles with aerodynamic diameters<2.5μm; PM 2.5 ) and coarse (particles with aerodynamic diameters <10μm and >2.5μm; PMc) particulate matter. Endotoxin, predominantly found within the coarse fraction of airborne particulate matter, is associated with proinflammatory effects and adverse outcomes among susceptible populations. The aim of this study was to assess the efficacy of air filter interventions in reducing indoor PM 2.5 , PMc, and PMc-associated endotoxin concentrations in homes using a wood stove for primary heating. Homes (n=48) were randomized to receive in-room air filtration units with either a high efficiency filter (i.e. active) or a lower efficiency fiberglass filter (i.e., placebo). The active filter intervention showed a 66% reduction in indoor PM 2.5 concentrations (95% CI: 42.2% to 79.7% reduction) relative to the placebo intervention. Both the active and the placebo filters were effective in substantially reducing indoor concentrations of PMc (63.3% and 40.6% average reduction for active and placebo filters, respectively) and PMc-associated endotoxin concentrations (91.8% and 80.4% average reductions, respectively). These findings support the use of high efficiency air filtration units for reducing indoor PM 2.5 in homes using a wood stove for primary heating. We also discovered that using lower efficiency, lower cost filter alternatives can be effective for reducing PMc and airborne endotoxin in homes burning biomass fuel. Copyright © 2017. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Kraus, Michal; Juhásová Šenitková, Ingrid
2017-10-01
Building environmental audit and the assessment of indoor air quality (IAQ) in typical residential buildings is necessary process to ensure users’ health and well-being. The paper deals with the concentrations on indoor dust particles (PM10) in the context of hygrothermal microclimate in indoor environment. The indoor temperature, relative humidity and air movement are basic significant factors determining the PM10 concentration [μg/m3]. The experimental measurements in this contribution represent the impact of indoor physical parameters on the concentration of particulate matter mass concentration. The occurrence of dust particles is typical for the almost two-thirds of interiors of the buildings. Other parameters indoor environment, such as air change rate, volume of the room, roughness and porosity of the building material surfaces, static electricity, light ions and others, were set constant and they are not taken into account in this study. The mass concentration of PM10 is measured during summer season in apartment of residential prefabricated building. The values of global temperature [°C] and relative humidity of indoor air [%] are also monitored. The quantity of particulate mass matter is determined gravimetrically by weighing according to CSN EN 12 341 (2014). The obtained results show that the temperature difference of the internal environment does not have a significant effect on the concentration PM10. Vice versa, the difference of relative humidity exhibits a difference of the concentration of dust particles. Higher levels of indoor particulates are observed for low values of relative humidity. The decreasing of relative air humidity about 10% caused 10µg/m3 of PM10 concentration increasing. The hygienic limit value of PM10 concentration is not exceeded at any point of experimental measurement.
The Unsolved Mysteries of Atmospheric Chemistry for High School Students and Teachers
NASA Astrophysics Data System (ADS)
Simonich, S. L.
2011-12-01
The grant "CAREER: New Molecular Markers of Asian Air Emissions - Anthropogenic Semi-Volatile Organic Compounds" (ATM-0239823) was funded by NSF from 2003-2008. The CAREER proposal described the integration of research and outreach education activities in the field of atmospheric chemistry, specifically atmospheric measurements and atmospheric transport. The primary objective of the research was to identify anthropogenic semi-volatile organic compounds (SOCs) that could be used as molecular markers for Asian air emissions and trans-Pacific atmospheric transport. The outreach education activity was integrated with the research by developing curriculum to introduce underrepresented minority high school students, and their teachers, to atmospheric chemistry and atmospheric measurements through Oregon State University's National Institute of Environmental Health Sciences funded Hydroville Curriculum Project (http://www.hydroville.org/iaq_resources). A curriculum was developed to allow students to assume the role of "Air Quality Scientist" and measure air temperature, air flow, relative humidity, CO, CO2, O3, and volatile organic compounds in out-door and in-door air. The students gained an understanding of atmospheric transport and compared measured concentrations to recommended guidelines. In addition, the outreach education activities included the development of the "Unsolved Mysteries of Human Health" website (http://www.unsolvedmysteries.oregonstate.edu/), including a specific module on the research conducted under the CAREER grant (http://www.unsolvedmysteries.oregonstate.edu /Gas-Chromatography-Mass-Spectrometry-Overview). The PI of the CAREER proposal, Dr. Staci Massey Simonich, is now a full professor at Oregon State University. To date, she has published over 50 peer-review journal articles, as well as mentored 9 undergraduate students, 20 graduate students, 3 post-doctoral scholars, and 3 international visiting scientists in her laboratory.
ERIC Educational Resources Information Center
Jitendra, Asha K.; Petersen-Brown, Shawna; Lein, Amy E.; Zaslofsky, Anne F.; Kunkel, Amy K.; Jung, Pyung-Gang; Egan, Andrea M.
2015-01-01
This study examined the quality of the research base related to strategy instruction priming the underlying mathematical problem structure for students with learning disabilities and those at risk for mathematics difficulties. We evaluated the quality of methodological rigor of 18 group research studies using the criteria proposed by Gersten et…
Wolchik, Sharlene A; Tein, Jenn-Yun; Sandler, Irwin N; Doyle, Kathryn W
2002-08-01
This study examines whether fear of abandonment mediates the prospective relations between divorce stressors and mother-child relationship quality and adjustment problems of children of divorce. Participants were 216 children, ages 8-12, and their primary residential mothers. Children reported on divorce stressors and fear of abandonment; mothers and children reported on mother-child relationship quality and internalizing and externalizing problems. Structural equation models indicated that Time 1 fear of abandonment mediated the relation between Time 1 divorce stressors and Time 2 internalizing and externalizing problems. Time 1 fear of abandonment also mediated the relation between Time 1 mother-child relationship quality and Time 2 internalizing and externalizing problems. Implications of these results for understanding variability in children's postdivorce adjustment problems and interventions for divorced families are discussed.
Depressive symptoms, smoking, drinking, and quality of life among head and neck cancer patients.
Duffy, Sonia A; Ronis, David L; Valenstein, Marcia; Fowler, Karen E; Lambert, Michael T; Bishop, Carol; Terrell, Jeffrey E
2007-01-01
The authors examined the relationship between depressive symptoms, smoking, problem drinking, and quality of life among 973 head and neck cancer patients who were surveyed and had their charts audited. Forty-six percent screened positive for depressive symptoms, 30% smoked, and 16% screened positive for problem drinking. Controlling for clinical and demographic variables, linear-regression analyses showed that depressive symptoms had a strong negative association with all 12 quality-of-life scales; smoking had a negative association on all but one of the quality-of-life scales; and problem drinking was not associated with any of the quality-of-life scales. Interventions targeting depression, smoking, and problem drinking need to be integrated into oncology clinics.
NASA Astrophysics Data System (ADS)
Molinie, Jack; Bernard, Marie-Lise; Komorowski, Jean-Christophe; Euphrasie-Clotilde, Lovely; Brute, France-Nor; Roussas, Andre
2014-05-01
On the 11 February 2010, fifteen minutes after midday, an explosive eruption of Soufriere Hills volcano sent tephra over the neighbour Caribbean islands. The volcanic ashes benefit from the vertical wind distribution of the moment to reach Guadeloupe island and cover it ground near 5 hours after the ash venting. Since the first ashes arrival over the town of Pointe-a-Pitre (located at 80 km at the South East of Soufriere hills volcano) to the end of the event, we measured the mean particle concentrations and particle size distributions every twenty minutes. Measurements were performed at a building roof of the town using an optical particles counter Lighthouse IAQ 3016 mainly used in indoor air quality studies and which provides up to 6 particle size channels of simultaneous counting with aerodynamic diameters classes ranging from 0.3 to >10 µm. The airborne particulate matter mass concentration, with equivalent aerodynamic diameters less than 10 µm (PM10) were measured by the local air quality network Gwad'air, in the vicinity of the site used to study this ash fall.. The maximum concentration of small particles with diameter lesser than 1µm (D0.3-1) was observed one hour before the larger particles. This result may imply a difference in shape and density between particles D0.3-1 and particles D1-10 (1
Oldenkamp, Marloes; Hagedoorn, Mariët; Wittek, Rafael; Stolk, Ronald; Smidt, Nynke
2017-10-01
To examine the impact of changes in an older person's frailty on the care-related quality of life of their informal caregiver. Five research projects in the TOPICS-MDS database with data of both older person and informal caregiver at baseline and after 12 months follow-up were selected. Frailty was measured in five health domains (functional limitations, psychological well-being, social functioning, health-related quality of life, self-rated health). Care-related quality of life was measured with the Care-Related Quality of Life instrument (CarerQoL-7D), containing two positive (fulfilment, perceived support) and five negative dimensions (relational problems, mental health problems, physical health problems, financial problems, problems combining informal care with daily activities). 660 older person/caregiver couples were included. Older persons were on average 79 (SD 6.9) years of age, and 61% was female. Caregivers were on average 65 (SD 12.6) years of age, and 68% was female. Results of the multivariable linear and logistic regression analyses showed that an increase in older person's frailty over time was related to a lower total care-related quality of life of the caregiver, and to more mental and physical health problems, and problems with combining informal care with daily activities at follow-up. A change in the older person's psychological well-being was most important for the caregiver's care-related quality of life, compared to the other health domains. Health professionals observing decreasing psychological well-being of an older person and increasing hours of informal care provision should be aware of the considerable problems this may bring to their informal caregiver, and should tailor interventions to support informal caregivers according to their specific needs and problems.
ERIC Educational Resources Information Center
Buist, Kirsten L.; Verhoeven, Marjolein; Hoksbergen, René; ter Laak, Jan; Watve, Sujala; Paranjpe, Analpa
2017-01-01
The aims of the present study were (a) to examine whether Dutch and Indian early adolescents differ concerning sibling and parent-child relationship quality and externalizing and internalizing problems, and (b) to compare the associations between sibling and parent-child relationship quality and externalizing and internalizing problems for Indian…
ERIC Educational Resources Information Center
Bull, Elizabeth Kay
The goal of this study was to find a way to quantify three criteria of representational quality, described by Greeno, so that it would be possible to examine statistically the relationship between representational quality and other variables related to problem solution. The sample consisted of 18 college students, 84 percent of whom had…
Broekhuizen, Martine L.; Mokrova, Irina L.; Burchinal, Margaret R.; Garrett-Peters, Patricia T.
2016-01-01
Focusing on the continuity in the quality of classroom environments as children transition from preschool into elementary school, this study examined the associations between classroom quality in pre-kindergarten and kindergarten and children’s social skills and behavior problems in kindergarten and first grade. Participants included 1175 ethnically-diverse children (43% African American) living in low-wealth rural communities of the US. Results indicated that children who experienced higher levels of emotional and organizational classroom quality in both pre-kindergarten and kindergarten demonstrated better social skills and fewer behavior problems in both kindergarten and first grade comparing to children who did not experience higher classroom quality. The examination of the first grade results indicated that the emotional and organizational quality of pre-kindergarten classrooms was the strongest predictor of children’s first grade social skills and behavior problems. The study results are discussed from theoretical, practical, and policy perspectives. PMID:26949286
Eslaminejad, Alireza; Safa, Mitra; Ghassem Boroujerdi, Fatemeh; Hajizadeh, Farzaneh; Pashm Foroush, Maryam
2017-10-01
We aimed to study sleep problems in hospitalized chronic obstructive pulmonary disease patients and assess the relationship of sleep quality with mental health and demographics of patients. Our study sample consisted of 850 chronic obstructive pulmonary disease patients hospitalized in Masih Daneshvari Hospital. Demographic data were collected and the Pittsburgh Sleep Quality and mental health questionnaires were filled out for patients. The results showed that 5.9 percent were suffering from severe sleep problems, while 4.7 percent had severe mental problems. A strong positive correlation was found between the total scores of mental health and sleep quality ( p < 0.01). The prevalence of sleep and mental health problems was higher in females compared to males. Mental health and sleep quality play important roles in quality of life of chronic obstructive pulmonary disease patients.
Hill, Douglas L; Miller, Victoria A; Hexem, Kari R; Carroll, Karen W; Faerber, Jennifer A; Kang, Tammy; Feudtner, Chris
2015-10-01
The quality of shared decision making for children with serious illness may depend on whether parents and physicians share similar perceptions of problems and hopes for the child. (i) Describe the problems and hopes reported by mothers, fathers and physicians of children receiving palliative care; (ii) examine the observed concordance between participants; (iii) examine parental perceived agreement; and (iv) examine whether parents who identified specific problems also specified corresponding hopes, or whether the problems were left 'hopeless'. Seventy-one parents and 43 physicians were asked to report problems and hopes and perceived agreement for 50 children receiving palliative care. Problems and hopes were classified into eight domains. Observed concordance was calculated between parents and between each parent and the physicians. The most common problem domains were physical body (88%), quality of life (74%) and medical knowledge (48%). The most common hope domains were quality of life (88%), suffering (76%) and physical body (39%). Overall parental dyads demonstrated a high percentage of concordance (82%) regarding reported problem domains and a lower percentage of concordance on hopes (65%). Concordance between parents and physicians regarding specific children was lower on problem (65-66%) and hope domains (59-63%). Respondents who identified problems regarding a child's quality of life or suffering were likely to also report corresponding hopes in these domains (93 and 82%, respectively). Asking parents and physicians to talk about problems and hopes may provide a straightforward means to improve the quality of shared decision making for critically ill children. © 2013 John Wiley & Sons Ltd.
Pangalila, Robert F; van den Bos, Geertrudis A M; Bartels, Bart; Bergen, Michael P; Kampelmacher, Mike J; Stam, Henk J; Roebroeck, Marij E
2015-02-01
To assess quality of life of adults with Duchenne muscular dystrophy in the Netherlands and to identify domains and major problems influencing quality of life. Cross-sectional. Seventy-nine men aged ≥ 20 years with Duchenne muscular dystrophy. The Medical Outcome Study Short Form-36 (SF-36), World Health Organization Quality of Life - BREF (WHOQOL-BREF) and an interview were used to assess quality of life and problems. Compared with Dutch general population reference values, the SF-36 domains scores were lower on all domains except mental health and role limitations due to emotional problems. On the WHOQOL-BREF the social relationships domain score was lower. Main problems were intimate relationships, work, leisure, transport and meaningfulness of life. Seventy-three percent stated overall quality of life as "(very) good". The SF-36 domains mental health (rs 0.53, p < 0.001) and vitality (rs 0.49, p < 0.001) had the strongest associations with overall quality of life. Adult men with Duchenne muscular dystrophy assess their health status as low in the physical, but not in the mental, domains. Experienced problems are mainly in the area of participation. They are generally satisfied with their overall quality of life.
[Health-related quality of life evaluation of elderly aged 65 years and over living at home].
Jalenques, I; Auclair, C; Rondepierre, F; Gerbaud, L; Tourtauchaux, R
2015-06-01
To assess health-related quality of life in French adults aged 65 years and over, living at home, with a specific self-administered questionnaire, the LEIPAD, cross-culturally adapted in French. Elderly completed socio-demographic and medical questionnaires, a questionnaire about negative life events during the last 12 months and the LEIPAD. Data of 195 subjects (mean age: 72.6 years, men: 56.5%) were analyzed. The response rates to the LEIPAD scales were superior to 90%. Elderly reported on the whole a good health-related quality of life. Age had a negative effect on quality on life, which deteriorates over years. Age was correlated to the scales "Physical function", "Self-care", "Cognitive functioning" and "Sexual functioning". Elderly hospitalized in the last year had worse quality of life with a significant difference for "Physical function" scale. The number of health problems was positively correlated to "Physical function" scale. Elderly declaring at least one health problem had worse quality of life for this scale. Problems in couple, materials and financial problems had also negative effects on health-related quality of life. Our study highlights a good health-related quality of life for the majority of these adults aged 65 years and over, as well as the negative effect of age, health, couple, materials and financial problems on their quality of life. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
NASA Astrophysics Data System (ADS)
Awi; Ahmar, A. S.; Rahman, A.; Minggi, I.; Mulbar, U.; Asdar; Ruslan; Upu, H.; Alimuddin; Hamda; Rosidah; Sutamrin; Tiro, M. A.; Rusli
2018-01-01
This research aims to reveal the profile about the level of creativity and the ability to propose statistical problem of students at Mathematics Education 2014 Batch in the State University of Makassar in terms of their cognitive style. This research uses explorative qualitative method by giving meta-cognitive scaffolding at the time of research. The hypothesis of research is that students who have field independent (FI) cognitive style in statistics problem posing from the provided information already able to propose the statistical problem that can be solved and create new data and the problem is already been included as a high quality statistical problem, while students who have dependent cognitive field (FD) commonly are still limited in statistics problem posing that can be finished and do not load new data and the problem is included as medium quality statistical problem.
Dispositional Mindfulness and Memory Problems: The Role of Perceived Stress and Sleep Quality
Brisbon, Nicholas M.; Lachman, Margie E.
2016-01-01
There is a growing body of evidence exploring the beneficial effects of mindfulness on stress, sleep quality, and memory, though the mechanisms involved are less certain. The present study explored the roles of perceived stress and sleep quality as potential mediators between dispositional mindfulness and subjective memory problems. Data were from a Boston area subsample of the Midlife in the United States study (MIDUS-II) assessed in 2004–2006, and again approximately one year later (N=299). As expected, higher dispositional mindfulness was associated with lower perceived stress and better sleep quality. There was no direct association found between mindfulness and subjective memory problems, however, there was a significant indirect effect through perceived stress, although not with sleep quality. The present findings suggest that perceived stress may play a mediating role between dispositional mindfulness and subjective memory problems, in that those with higher mindfulness generally report experiencing less stress than those with lower mindfulness, which may be protective of memory problems in everyday life. PMID:28344682
Dispositional Mindfulness and Memory Problems: The Role of Perceived Stress and Sleep Quality.
Brisbon, Nicholas M; Lachman, Margie E
2017-04-01
There is a growing body of evidence exploring the beneficial effects of mindfulness on stress, sleep quality, and memory, though the mechanisms involved are less certain. The present study explored the roles of perceived stress and sleep quality as potential mediators between dispositional mindfulness and subjective memory problems. Data were from a Boston area subsample of the Midlife in the United States study (MIDUS-II) assessed in 2004-2006, and again approximately one year later (N=299). As expected, higher dispositional mindfulness was associated with lower perceived stress and better sleep quality. There was no direct association found between mindfulness and subjective memory problems, however, there was a significant indirect effect through perceived stress, although not with sleep quality. The present findings suggest that perceived stress may play a mediating role between dispositional mindfulness and subjective memory problems, in that those with higher mindfulness generally report experiencing less stress than those with lower mindfulness, which may be protective of memory problems in everyday life.
Mental Health, School Problems, and Social Networks: Modeling Urban Adolescent Substance Use
ERIC Educational Resources Information Center
Mason, Michael J.
2010-01-01
This study tested a mediation model of the relationship with school problems, social network quality, and substance use with a primary care sample of 301 urban adolescents. It was theorized that social network quality (level of risk or protection in network) would mediate the effects of school problems, accounting for internalizing problems and…
ERIC Educational Resources Information Center
Krause, Kerri-Lee
2012-01-01
This article explores the wicked problem of quality in higher education, arguing for a more robust theorising of the subject at national, institutional and local department level. The focus of the discussion rests on principles for theorising in more rigorous ways about the multidimensional issue of quality. Quality in higher education is proposed…
Reinventing Teaching and Testing: Quality Learning for Quality Employment.
ERIC Educational Resources Information Center
Cooke, Brian P.
To succeed in today's competitive global markets, organizations are hiring responsible problem solvers and collaborative "associates" who improve productivity, assure quality service, and contribute creatively. These organizations demand employees who are skilled at learning to learn, listening, communicating, problem solving, teamwork,…
Self-reported distress in patients with ovarian cancer: is it related to disease status?
Ploos van Amstel, Floortje K; van Ham, Maaike A P C; Peters, Esmee J; Prins, Judith B; Ottevanger, Petronella B
2015-02-01
Patients with epithelial ovarian cancer have a poor prognosis and often undergo intensive treatment. These patients are therefore at risk for experiencing distress and reduced quality of life. The aim of this study was to explore the self-reported distress severity, experienced problems, and quality of life in relation to their disease status. This cross-sectional study was conducted in 2011 at a University Medical Center. Women with ovarian cancer (n = 273), both during and after treatment, were asked by mail to fill in self-report questionnaires. Distress was measured using with the Distress Thermometer (DT), Hospital Anxiety and Depression Scale, and Impact of Event Scale. Problems and quality of life were assessed with the problem list of the DT, and European Organization for Research and Treatment of Cancer Quality of Life C-30 and OV28. The questionnaire data of 104 patients were analyzed. Screening with the DT revealed distress in 32% [mean (SD), 3.1 (2.6)]. Distress was found with the Hospital Anxiety and Depression Scale in 14% [8.6 (5.9)] and with the Impact of Event Scale in 18% of the patients [17.5 (15.5)]. No significant differences were found in distress severity and self-reported problems between patients with and without recurrence. In both groups, the problems fatigue, condition, and neuropathy were most reported. Patients with distress (DT ≥ 5) experienced significantly worse functioning, more problems, and lower quality of life than patients without distress (P < 0.01). This study showed that disease status in patients with ovarian cancer seems to have no influence on distress, quality of life, and the problems encountered. However, distressed patients experienced more problems, with physical and emotional functioning, and had lower quality of life. The problems fatigue, physical condition, and neuropathy are the most prevailing.
NASA Astrophysics Data System (ADS)
Wirawan, Christina; Chandra, Fory
2016-02-01
Theory of Inventive Problem Solving (TRIZ) is a creative encouraging problem solving method. TRIZ is prepared by Altshuller for product design. Altshuller prepared contradiction matrix and suggestion to solve contradictions usually occur in product design. This paper try to combine TRIZ with quality tools such as Pareto and Fault Tree Analysis (FTA) to solve contradiction in quality improvement problem, neither than product design problem. Pareto used to identify defect priority, FTA used to analysis and identify root cause of defect. When there is contradiction in solving defect causes, TRIZ used to find creative problem solving. As a case study, PT ’X’, a plastic molding manufacturing industry was taken. PT ‘X’ using traditional press machine to produce plastic thread cone. There are 5 defect types that might occur in plastic thread cone production, incomplete form, dirty, mottle, excessive form, rugged. Research about quality improvement effort using DMAIC at PT ‘X’ have been done by Fory Candra. From this research, defect types, priority, root cause from FTA, recommendation from FMEA. In this research, from FTA reviewed, contradictions found among causes troublesome quality improvement efforts. TRIZ used to solve the contradictions and quality improvement effort can be made effectively.
ERIC Educational Resources Information Center
Lee, John
2002-01-01
The problem of ensuring quality in mass education systems is as old as the systems themselves. Responses to this problem reflect the political and cultural organisation of different nation states. In the USA the problem has to be dealt with at a local level. The federal government is very restricted in powers in the field of education and social…
7 CFR 634.12 - Eligible project areas.
Code of Federal Regulations, 2010 CFR
2010-01-01
... agricultural portion of a 208 water quality management plan, or revised portions thereof, and have identified agricultural nonpoint source water quality problems are eligible for authorization under RCWP. Those critical areas or sources of pollutants significantly contributing to the water quality problems are eligible for...
Exploring the relationship between work-related rumination, sleep quality, and work-related fatigue.
Querstret, Dawn; Cropley, Mark
2012-07-01
This study examined the association among three conceptualizations of work-related rumination (affective rumination, problem-solving pondering, and detachment) with sleep quality and work-related fatigue. It was hypothesized that affective rumination and poor sleep quality would be associated with increased fatigue and that problem-solving pondering and detachment would be associated with decreased fatigue. The mediating effect of sleep quality on the relationship between work-related rumination and fatigue was also tested. An online questionnaire was completed by a heterogeneous sample of 719 adult workers in diverse occupations. The following variables were entered as predictors in a regression model: affective rumination, problem-solving pondering, detachment, and sleep quality. The dependent variables were chronic work-related fatigue (CF) and acute work-related fatigue (AF). Affective rumination was the strongest predictor of increased CF and AF. Problem-solving pondering was a significant predictor of decreased CF and AF. Poor sleep quality was predictive of increased CF and AF. Detachment was significantly negatively predictive for AF. Sleep quality partially mediated the relationship between affective rumination and fatigue and between problem-solving pondering and fatigue. Work-related affective rumination appears more detrimental to an individual's ability to recover from work than problem-solving pondering. In the context of identifying mechanisms by which demands at work are translated into ill-health, this appears to be a key finding and suggests that it is the type of work-related rumination, not rumination per se, that is important.
Quality of life of people with mental health problems: a synthesis of qualitative research
2012-01-01
Purpose To identify the domains of quality of life important to people with mental health problems. Method A systematic review of qualitative research undertaken with people with mental health problems using a framework synthesis. Results We identified six domains: well-being and ill-being; control, autonomy and choice; self-perception; belonging; activity; and hope and hopelessness. Firstly, symptoms or ‘ill-being’ were an intrinsic aspect of quality of life for people with severe mental health problems. Additionally, a good quality of life was characterised by the feeling of being in control (particularly of distressing symptoms), autonomy and choice; a positive self-image; a sense of belonging; engagement in meaningful and enjoyable activities; and feelings of hope and optimism. Conversely, a poor quality life, often experienced by those with severe mental health difficulties, was characterized by feelings of distress; lack of control, choice and autonomy; low self-esteem and confidence; a sense of not being part of society; diminished activity; and a sense of hopelessness and demoralization. Conclusions Generic measures fail to address the complexity of quality of life measurement and the broad range of domains important to people with mental health problems. PMID:23173689
Modelling voltage sag mitigation using dynamic voltage restorer and analyzing power quality issue
NASA Astrophysics Data System (ADS)
Ismail, Nor Laili; Hidzir, Hizrin Dayana Mohd; Thanakodi, Suresh; Nazar, Nazatul Shiema Moh; Ibrahim, Pungut; Ali, Che Ku Muhammad Sabri Che Ku
2018-02-01
Power quality problem which are arise due to a fault or a pulsed load can have caused an interruption of critical load. The modern power systems are becoming more sensitive to the quality of the power supplied by the utility company. Voltage sags and swells, flicker, interruptions, harmonic distortion and other distortion to the sinusoidal waveform are the examples of the power quality problems. The most affected due to these problems is industrial customers who use a lot of sensitive equipment. There has suffered a huge loss to these problems. Resulting of broken or damage equipment if voltage sag exceeds the sensitive threshold of the equipment. Thus, device such as Static Synchronous Compensator (STATCOM) and Dynamic Voltage Restorer (DVR) has been created to solve this problem among users. DVR is a custom power device that most effective and efficient. This paper intended to report the DVR operations during voltage sag compensation.
On the Problems of Asking for a Definition of Quality in Education
ERIC Educational Resources Information Center
Wittek, Line; Kvernbekk, Tone
2011-01-01
In this article we discuss the problems of asking for a definition of quality in education from a philosophy of language perspective. We take the concept of quality as it appears in higher education discourse as our example. More specifically we discuss the possibility of obtaining a precise, unified definition of quality by addressing the problem…
EPA RESEARCH HIGHLIGHTS -- MODELS-3/CMAQ OFFERS COMPREHENSIVE APPROACH TO AIR QUALITY MODELING
Regional and global coordinated efforts are needed to address air quality problems that are growing in complexity and scope. Models-3 CMAQ contains a community multi-scale air quality modeling system for simulating urban to regional scale pollution problems relating to troposphe...
Valuing U.S. Water Quality at Regional and National Scales
Assessing and monetizing the benefits of water quality at a regional and/or national scale is a challenging problem. One of the biggest problems is a lack of consistency in the monitoring and assessment methods used by states to assess water quality. Despite this inconsistency,...
Erdley-Kass, Shiloh D; Kass, Darrin S; Gellis, Zvi D; Bogner, Hillary A; Berger, Andrea; Perkins, Robert M
2017-08-24
To determine the effectiveness of Problem-Solving Therapy (PST) in older hemodialysis (HD) patients by assessing changes in health-related quality of life and problem-solving skills. 33 HD patients in an outpatient hemodialysis center without active medical and psychiatric illness were enrolled. The intervention group (n = 15) received PST from a licensed social worker for 6 weeks, whereas the control group (n = 18) received usual care treatment. In comparison to the control group, patients receiving PST intervention reported improved perceptions of mental health, were more likely to view their problems with a positive orientation and were more likely to use functional problem-solving methods. Furthermore, this group was also more likely to view their overall health, activity limits, social activities and ability to accomplish desired tasks with a more positive mindset. The results demonstrate that PST may positively impact mental health components of quality of life and problem-solving coping among older HD patients. PST is an effective, efficient, and easy to implement intervention that can benefit problem-solving abilities and mental health-related quality of life in older HD patients. In turn, this will help patients manage their daily living activities related to their medical condition and reduce daily stressors.
ERIC Educational Resources Information Center
Environmental Science and Technology, 1972
1972-01-01
State plans for implementing air quality standards are evaluated together with problems in modeling procedures and enforcement. Monitoring networks, standards, air quality regions, and industrial problems are also discussed. (BL)
Instructional Qualities of a Successful Mathematical Problem-Solving Class.
ERIC Educational Resources Information Center
Santos-Trigo, Manuel
1998-01-01
Describes activities that have been successfully implemented by an expert during a mathematical problem-solving course. Focuses on the identification of the qualities of these problems used to promote the development of student strategies and values that reflect mathematical practice in the classroom. Contains 17 references. (ASK)
ERIC Educational Resources Information Center
Nelson, Jackie A.
2015-01-01
Constructive parent-child conflict interactions that teach children to problem-solve and negotiate can enhance children's social adjustment. This paper identifies constructive and destructive qualities of mother-child conflict and explores whether child temperament moderated associations with changes in externalizing problems over time. One…
Quality of Rapport as a Setting Event for Problem Behavior: Assessment and Intervention
ERIC Educational Resources Information Center
McLaughlin, Darlene Magito; Carr, Edward G.
2005-01-01
Relationship quality (rapport) between people with developmental disabilities and their caregivers has long been suggested as an important variable influencing the likelihood of problem behavior. However, to date, the association between rapport and problem behavior has not been systematically investigated. The authors evaluated a multimethod…
Auditing and Evaluating Quality: Questions and Problems
ERIC Educational Resources Information Center
Vostrikov, A.
2004-01-01
For many Russian universities, improving the quality of education has become a central problem. Colleges and universities that have traditionally enjoyed high academic authority are not especially concerned about it; they are more concerned about the problems of financing and their own development. But for relatively young educational institutions…
Internalizing Problems among Cyberbullying Victims and Moderator Effects of Friendship Quality
ERIC Educational Resources Information Center
Aoyama, Ikuko; Saxon, Terrill F.; Fearon, Danielle D.
2011-01-01
Purpose: The purpose of this paper is to examine the relationship between cyberbullying victimization and internalizing problems among the youth. Moderator effects of a friendship quality were also investigated to examine if higher friendship quality moderated the negative effects of cyberbullying on psychological states of students.…
ERIC Educational Resources Information Center
Holmes, Stephen D.; He, Qingping; Meadows, Michelle
2017-01-01
The relationship between the characteristics of 33 mathematical problem-solving questions answered by 16-year-old students in England and the quality of problem-solving elicited was investigated in two studies. The first study used comparative judgement (CJ) to estimate the quality of the problem-solving elicited by each question, involving 33…
Hospital financial condition and the quality of patient care.
Bazzoli, Gloria J; Chen, Hsueh-Fen; Zhao, Mei; Lindrooth, Richard C
2008-08-01
Concerns about deficiencies in the quality of care delivered in US hospitals grew during a time period when an increasing number of hospitals were experiencing financial problems. Our study examines a six-year longitudinal database of general acute care hospitals in 11 states to assess the relationship between hospital financial condition and quality of care. We evaluate two measures of financial performance: operating margin and a broader profitability measure that encompasses both operating and non-operating sources of income. Our model specification allows for gradual adjustments in quality-enhancing activities and recognizes that current realizations of patient quality may affect future financial performance. Empirical results suggest that there is a relationship between financial performance and quality of care, but not as strong as suggested in earlier research. Overall, our results suggest that deep financial problems that go beyond the patient care side of business may be important to prompting quality problems. Copyright (c) 2007 John Wiley & Sons, Ltd.
Quality assurance paradigms for artificial intelligence in modelling and simulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oren, T.I.
1987-04-01
New classes of quality assurance concepts and techniques are required for the advanced knowledge-processing paradigms (such as artificial intelligence, expert systems, or knowledge-based systems) and the complex problems that only simulative systems can cope with. A systematization of quality assurance problems as well as examples are given to traditional and cognizant quality assurance techniques in traditional and cognizant modelling and simulation.
Coping and social problem solving correlates of asthma control and quality of life.
McCormick, Sean P; Nezu, Christine M; Nezu, Arthur M; Sherman, Michael; Davey, Adam; Collins, Bradley N
2014-02-01
In a sample of adults with asthma receiving care and medication in an outpatient pulmonary clinic, this study tested for statistical associations between social problem-solving styles, asthma control, and asthma-related quality of life. These variables were measured cross sectionally as a first step toward more systematic application of social problem-solving frameworks in asthma self-management training. Recruitment occurred during pulmonology clinic service hours. Forty-four adults with physician-confirmed diagnosis of asthma provided data including age, gender, height, weight, race, income, and comorbid conditions. The Asthma Control Questionnaire, the Mini Asthma Quality of Life Questionnaire (Short Form), and peak expiratory force measures offered multiple views of asthma health at the time of the study. Maladaptive coping (impulsive and careless problem-solving styles) based on transactional stress models of health were assessed with the Social Problem-Solving Inventory-Revised: Short Form. Controlling for variance associated with gender, age, and income, individuals reporting higher impulsive-careless scores exhibited significantly lower scores on asthma control (β = 0.70, p = 0.001, confidence interval (CI) [0.37-1.04]) and lower asthma-related quality of life (β = 0.79, p = 0.017, CI [0.15-1.42]). These findings suggest that specific maladaptive problem-solving styles may uniquely contribute to asthma health burdens. Because problem-solving coping strategies are both measureable and teachable, behavioral interventions aimed at facilitating adaptive coping and problem solving could positively affect patient's asthma management and quality of life.
Quality end-of-life care: A global perspective
Singer, Peter A; Bowman, Kerry W
2002-01-01
Background Quality end-of-life care has emerged as an important concept in industrialized countries. Discussion We argue quality end-of-life care should be seen as a global public health and health systems problem. It is a global problem because 85 % of the 56 million deaths worldwide that occur annually are in developing countries. It is a public health problem because of the number of people it affects, directly and indirectly, in terms of the well being of loved ones, and the large-scale, population based nature of some possible interventions. It is a health systems problem because one of its main features is the need for better information on quality end-of-life care. We examine the context of end-of-life care, including the epidemiology of death and cross-cultural considerations. Although there are examples of success, we could not identify systematic data on capacity for delivering quality end-of-life care in developing countries. We also address a possible objection to improving end-of-life care in developing countries; many deaths are preventable and reduction of avoidable deaths should be the focus of attention. Conclusions We make three recommendations: (1) reinforce the recasting of quality end-of-life care as a global public health and health systems problem; (2) strengthen capacity to deliver quality end-of-life care; and (3) develop improved strategies to acquire information about the quality of end-of-life care. PMID:12139768
Salvatore, J E; Prom-Wormley, E; Prescott, C A; Kendler, K S
2015-08-01
Alcohol consumption and problems are associated with interpersonal difficulties. We used a twin design to assess in men the degree to which genetic or environmental influences contributed to the covariance between alcohol consumption and problems, romantic quality and social support. The sample included adult male-male twin pairs (697 monozygotic and 487 dizygotic) for whom there were interview-based data on: alcohol consumption (average monthly alcohol consumption in the past year); alcohol problems (lifetime alcohol dependence symptoms); romantic conflict and warmth; friend problems and support; and relative problems and support. Key findings were that genetic and unique environmental factors contributed to the covariance between alcohol consumption and romantic conflict; genetic factors contributed to the covariance between alcohol problems and romantic conflict; and common and unique environmental factors contributed to the covariance between alcohol problems and friend problems. Recognizing and addressing the overlapping genetic and environmental influences that alcohol consumption and problems share with romantic quality and other indicators of social support may have implications for substance use prevention and intervention efforts.
ASHRAE and residential ventilation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sherman, Max H.
In the last quarter of a century, the western world has become increasingly aware of environmental threats to health and safety. During this period, people psychologically retreated away from outdoors hazards such as pesticides, smog, lead, oil spills, and dioxin to the seeming security of their homes. However, the indoor environment may not be healthier than the outdoor environment, as has become more apparent over the past few years with issues such as mold, formaldehyde, and sick-building syndrome. While the built human environment has changed substantially over the past 10,000 years, human biology has not; poor indoor air quality createsmore » health risks and can be uncomfortable. The human race has found, over time, that it is essential to manage the indoor environments of their homes. ASHRAE has long been in the business of ventilation, but most of the focus of that effort has been in the area of commercial and institutional buildings. Residential ventilation was traditionally not a major concern because it was felt that, between operable windows and envelope leakage, people were getting enough outside air in their homes. In the quarter of a century since the first oil shock, houses have gotten much more energy efficient. At the same time, the kinds of materials and functions in houses changed in character in response to people's needs. People became more environmentally conscious and aware not only about the resources they were consuming but about the environment in which they lived. All of these factors contributed to an increasing level of public concern about residential indoor air quality and ventilation. Where once there was an easy feeling about the residential indoor environment, there is now a desire to define levels of acceptability and performance. Many institutions--both public and private--have interests in Indoor Air Quality (IAQ), but ASHRAE, as the professional society that has had ventilation as part of its mission for over 100 years, is the logical place to provide leadership. This leadership has been demonstrated most recently by the publication of the first nationally recognized standard on ventilation in homes, ASHRAE Standard 62.2-2003, which builds on work that has been part of ASHRAE for many years and will presumably continue. Homeowners and occupants, which includes virtually all of us, will benefit from the application of Standard 62.2 and use of the top ten list. This activity is exactly the kind of benefit to society that the founders of ASHRAE envisioned and is consistent with ASHRAE's mission and vision. ASHRAE members should be proud of their Society for taking leadership in residential ventilation.« less
Code of Federal Regulations, 2010 CFR
2010-01-01
... (pooling ageement) with other land owners or operators to solve mutual water quality problems. Each participant must enter into an RCWP contract to treat water quality problems not covered by the joint...
Lorber, Michael F; Egeland, Byron
2009-07-01
Developmental models and previous findings suggest that early parenting is more strongly associated with externalizing problems in early childhood than it is in adolescence. In this article, the authors address whether the association of poor-quality infancy parenting and externalizing problems "rebounds" in adulthood. Poor-quality infancy parenting was associated with externalizing problems at kindergarten and first grade (mother report) as well as at 23 and 26 years (self report). Infancy parenting was not significantly associated with either mothers' or youths' reports of externalizing problems at 16 years. These findings are consistent with the notion that poor-quality infancy parenting is a risk factor for externalizing problems in developmental periods for which externalizing behavior is most deviant.
Image quality enhancement for skin cancer optical diagnostics
NASA Astrophysics Data System (ADS)
Bliznuks, Dmitrijs; Kuzmina, Ilona; Bolocko, Katrina; Lihachev, Alexey
2017-12-01
The research presents image quality analysis and enhancement proposals in biophotonic area. The sources of image problems are reviewed and analyzed. The problems with most impact in biophotonic area are analyzed in terms of specific biophotonic task - skin cancer diagnostics. The results point out that main problem for skin cancer analysis is the skin illumination problems. Since it is often not possible to prevent illumination problems, the paper proposes image post processing algorithm - low frequency filtering. Practical results show diagnostic results improvement after using proposed filter. Along that, filter do not reduces diagnostic results' quality for images without illumination defects. Current filtering algorithm requires empirical tuning of filter parameters. Further work needed to test the algorithm in other biophotonic applications and propose automatic filter parameter selection.
Friendship quality in adolescents with and without an intellectual disability.
Tipton, Leigh A; Christensen, Lisa; Blacher, Jan
2013-11-01
High friendship quality is often defined by high levels of intimacy, companionship, closeness and low levels of conflict. Quality friendships develop over time and may be influenced by both behaviour problems and social skills. Participants were 103, 13-year-old adolescents with or without intellectual disabilities in the United States. Adolescents and their mothers participated in an open-ended interview of friendship quality and completed measures of social skills and behaviour problems. This study addressed differences in friendship quality between children with and without intellectual disabilities and explored early indicators of friendship development. Adolescents with intellectual disabilities (ID) had friendships characterized by significantly lower levels of warmth/closeness and positive reciprocity than their typically developing peers. Likewise, adolescents with ID spent less time with friends outside of school and were less likely to have a cohesive group of friends. Social skills and behaviour problems at age 9 predicted friendship quality at age 13 above and beyond disability status, with higher levels of social skills and lower levels of behaviour problems related to higher ratings on measures of friendship quality. It appears that adolescents with intellectual disabilities have friendships that are characterized by less warmth/closeness and less positive reciprocity than the friendships of their typically developing peers. This discrepancy appears to be impacted by early social skills and behaviour problems in addition to the presence of the intellectual disability. © 2013 John Wiley & Sons Ltd.
Citrus Quality Control: An NMR/MRI Problem-Based Experiment
ERIC Educational Resources Information Center
Erhart, Sarah E.; McCarrick, Robert M.; Lorigan, Gary A.; Yezierski, Ellen J.
2016-01-01
An experiment seated in an industrial context can provide an engaging framework and unique learning opportunity for an upper-division physical chemistry laboratory. An experiment that teaches NMR/MRI through a problem-based quality control of citrus products was developed. In this experiment, using a problem-based learning (PBL) approach, students…
ERIC Educational Resources Information Center
Kim, Yeon Ha
2016-01-01
This study aims to explore the impact of early childhood educators' meta-cognitive knowledge on the quality of their childcare curriculum implementation, and to gain insights regarding successful problem-solving strategies associated with early education and care. Early childhood educators' implementation of general problem-solving strategies in…
An Examination of Special Focus Facility Nursing Homes
ERIC Educational Resources Information Center
Castle, Nicholas G.; Engberg, John
2010-01-01
Purpose: Nursing facilities that are determined to have a greater number of quality problems, more serious problems than average, and a demonstrated pattern of quality problems are included in the Special Focus Facility (SFF) initiative. The purpose of this research was to provide descriptive information on these SFFs and to examine the quality…
ERIC Educational Resources Information Center
Rebello, Carina M.
2012-01-01
This study explored the effects of alternative forms of argumentation on undergraduates' physics solutions in introductory calculus-based physics. A two-phase concurrent mixed methods design was employed to investigate relationships between undergraduates' written argumentation abilities, conceptual quality of problem solutions, as well…
Math Problems for Water Quality Control Personnel, Student Workbook. Second Edition.
ERIC Educational Resources Information Center
Delvecchio, Fred; Brutsch, Gloria
This document is the student workbook for a course in mathematics for water quality control personnel. This version contains complete problems, answers and references. Problems are arranged alphabetically by treatment process. Charts, graphs, and drawings represent data forms an operator might see in a plant containing information necessary for…
Development of an expert system for power quality advisement using CLIPS 6.0
NASA Technical Reports Server (NTRS)
Chandrasekaran, A.; Sarma, P. R. R.; Sundaram, Ashok
1994-01-01
Proliferation of power electronic devices has brought in its wake both deterioration in and demand for quality power supply from the utilities. The power quality problems become apparent when the user's equipment or systems maloperate or fail. Since power quality concerns arise from a wide variety of sources and the problem fixes are better achieved from the expertise of field engineers, development of an expert system for power quality advisement seems to be a very attractive and cost-effective solution for utility applications. An expert system thus developed gives an understanding of the adverse effects of power quality related problems on the system and could help in finding remedial solutions. The paper reports the design of a power quality advisement expert system being developed using CLIPS 6.0. A brief outline of the power quality concerns is first presented. A description of the knowledge base is next given and details of actual implementation include screen output from the program.
Problems of Accreditation and Quality Assurance of Engineering Education in Developing Countries.
ERIC Educational Resources Information Center
Bordia, Surek
2001-01-01
Discusses the relationship between funding, management, and quality assurance in engineering education in developing countries. Presents a few case studies on problems of accreditation and quality assessment in larger developing countries such as India and the Philippines, and also in very small developing countries such as Papua New Guinea, Fiji,…
Commitments to Improve the Quality of Learning.
ERIC Educational Resources Information Center
Cross, K. Patricia
For the nation as a whole, there is a moving bandwagon of educational change, clearly hitched to attempts to personalize and individualize instruction. The new emphases on the quality of learning appears to offer some potential solutions to two current problems: the twin problems of quality and equality in education. Traditional group-oriented…
Relationship between Sleep Quality and Health Risk Behaviors in Undergraduate College Students
ERIC Educational Resources Information Center
Vail-Smith, Karen; Felts, W. Michael; Becker, Craig
2009-01-01
The Sleep Quality Index (SQI) and the Centers for Disease Control's National College Health Risk Survey (NCHRS) were administered to 859 undergraduates at a large southeastern university. Results indicated that 76.6% reported occasional sleep problems and 11.8 % experienced poor sleep quality. Among the problems reported, "general morning…
ERIC Educational Resources Information Center
Pummill, Bret L.; Edson, Jerry C.; Loftin, Michelle M.; Robinson, Matthew A.
2011-01-01
This report describes a problem based learning project focusing on superintendents' knowledge of the characteristics of high quality teachers. Current research findings offer evidence teacher quality is an important school variable related to student achievement. School district leaders are faced with the problem of identifying the characteristics…
Franz, Annabel O; McKinney, Cliff
2018-03-26
Previous literature has not examined the processes underlying the relations among parent-child relationship quality, parental psychopathology, and child psychopathology in the context of gender. Further, research examining these variables in emerging adulthood is lacking. The current study examined whether parent-child relationship quality would mediate the relation between parental and child psychopathology, and whether gender moderated these associations. Participants were emerging adults (N = 665) who reported on perceptions of their parents' and their own psychological problems as well as their parent-child relationship quality. Results indicated that the relation between parental internalizing problems and parent-child relationship quality was positive for males, and that mother-child relationship quality was related positively to psychological problems in males. This suggests that sons may grow closer to their parents (particularly their mother) who are exhibiting internalizing problems; in turn, this enmeshed relationship may facilitate transmission of psychopathology. Mediational paths were conditional upon gender, suggesting moderated mediation. Overall, the current study emphasizes that the complexities of parenting must be understood in the context of gender. Further, the mother-son dyad may particularly warrant further attention.
Introductory astronomy course at the University of Cape Town: Probing student perspectives
NASA Astrophysics Data System (ADS)
Rajpaul, Vinesh; Allie, Saalih; Blyth, Sarah-Louise
2014-12-01
We report on research carried out to improve teaching and student engagement in the introductory astronomy course at the University of Cape Town. This course is taken by a diverse range of students, including many from educationally disadvantaged backgrounds. We describe the development of an instrument, the Introductory Astronomy Questionnaire (IAQ), which we administered as pre- and posttests to students enrolled in the course. The instrument comprised a small number of questions which probed three areas of interest: student motivation and expectations, astronomy content, and worldview. Amongst our findings were that learning gains were made in several conceptual areas, and that students appeared to develop a more nuanced view of the nature of astronomy. There was some evidence that the course had a positive impact on students' worldviews, particularly their attitudes towards science. We also identified a promising predictor of course success that could in the future be used to identify students requiring special teaching intervention.
ERIC Educational Resources Information Center
Taghdisi, M. H.; Borhani, M.; Solhi, M.; Afkari, M. E.; Hosseini, F.
2012-01-01
Background and objective: The problems caused by diabetes have direct and indirect impacts on the quality of life of diabetic patients. An increase of these problems means a decrease in a patient's quality of life. This study was conducted to assess the effect of the educational programme based on the precede model in promoting quality of life of…
Water-quality assessment of the Smith River drainage basin, California and Oregon
Iwatsubo, Rick T.; Washabaugh, Donna S.
1982-01-01
A water-quality assessment of the Smith River drainage basin was made to provide a summary of the water-quality conditions including known or potential water-quality problems. Results of the study showed that the water quality of the Smith River is excellent and generally meets the water-quality objectives for the beneficial uses identified by the California Regional Water Quality Control Board, North Coast Region. Known and potential problems related to water quality include: Sedimentation resulting from both natural erosional processes and land-use activities such as timber harvest, road construction, and mining that accelerate the erosional processes; bacterial contamination of surface and ground waters from inundated septic tanks and drainfields, and grazing activities; industrial spills which have resulted in fish kills and oil residues; high concetrations of iron in ground water; log and debris jams creating fish migration barriers; and pesticide and trace-element contamination from timber-harvest and mining activities, respectively. Future studies are needed to establish: (1) a sustained long-term monitoring program to provide a broad coverage of water-quality conditions in order to define long-term water-quality trends; and (2) interpretive studies to determine the source of known and potential water-quality problems. (USGS)
Quach, Jon; Hiscock, Harriet; Wake, Melissa
2012-12-01
To determine at school entry (i) the prevalence and types of child sleep problems; (ii) sleep difficulties and hygiene practices associated with sleep problems; and (iii) their associations with child health-related quality of life, mental health and parent mental health. We conducted a cross-sectional community-based study at 22 primary schools in Melbourne, Australia. One thousand five hundred and twelve (70%) parents of children in the first 6 months of the child's first year of primary school took part. Parent report of child sleep problems (none, mild, and moderate/severe); sleep difficulties; pre-bedtime activities (television in bedroom, television or electronic games before bedtime, television or electronic games >2 h/day) and caffeine intake; child mental health (Strengths and Difficulties Questionnaire), health-related quality of life (Pediatric Quality of Life Inventory); and parent mental health (Depression Anxiety Stress Scale-21). 38.6% of children had a parent-reported sleep problem (27.9% mild, 10.8% moderate/severe). Sleep problems were characterised by problematic sleep difficulties but not poor sleep hygiene practices. Moderate/severe sleep problems were associated with poorer child mental health (mean difference -0.8; 95% confidence interval (CI) -1.1 to -0.5, P < 0.001), health-related quality of life (mean difference -9.9; 95% CI -11.9 to -7.9, P < 0.001) and parent mental health (mean difference 9.8; 95% CI 7.7-11.9, P < 0.001). In new school entrants, sleep problems are common and associated with poorer child mental health, health-related quality of life and parent mental health. Future research needs to determine if systematically addressing sleep problems improves these outcomes. © 2012 The Authors. Journal of Paediatrics and Child Health © 2012 Paediatrics and Child Health Division (Royal Australasian College of Physicians).
Self-consciousness, friendship quality, and adolescent internalizing problems
Bowker, Julie C.; Rubin, Kenneth H.
2013-01-01
The correlates between public and private self-consciousness and internalizing difficulties were examined during early adolescence. Friendship quality was assessed as a possible moderator of the relation between self-consciousness and maladjustment. One hundred and thirty-seven young adolescents (N = 87 girls; M age = 13.98 years) reported on their self-consciousness, internalizing problems, and the quality of their best friendship. Results indicated stronger associations between private self-consciousness and internalizing correlates than between public self-consciousness and internalizing problems, suggesting that private self-consciousness may be a stronger risk factor during adolescence. Contrary to expectations, evidence revealed that positive friendship quality may exacerbate some difficulties associated with self-consciousness. Results pertaining to friendship quality add to the growing literature on the ways in which friendships can contribute to adjustment difficulties. PMID:19998530
The Effect of Shift Work on Quality and Stability of Marital Relations.
ERIC Educational Resources Information Center
White, Lynn; Keith, Bruce
1990-01-01
Interviewed a national panel of 1,668 married women and men in 1980 and 1983 to assess effects of shift work on 6 measures of marital quality (marital happiness, interaction, disagreements, general problems, sexual problems, and child-related problems) and probability of divorce. Results suggested that shift work has a modest but general adverse…
Quality Education Improvement: Yemen and the Problem of the "Brain Drain"
ERIC Educational Resources Information Center
Muthanna, Abdulghani
2015-01-01
This paper presents an overview of the problems that hinder improvement of the quality of education in Yemen, with a particular focus on higher education institutions. It discusses in particular the problem of the brain drain and why this phenomenon is occurring in Yemen. Semi-structured interviews with three professors at higher education…
Parental Sleep Quality and Behavior Problems of Children with Autism
ERIC Educational Resources Information Center
Mihaila, Iulia; Hartley, Sigan L.
2018-01-01
This study explored the impact of parental sleep quality on the experience of behavior problems by children with autism spectrum disorder. A 14-day daily diary was used in a sample of 176 mother-father couples. Dyadic multilevel models were conducted to examine the between-person and within-person effects of previous-night sleep quality on…
Information needs related to extension service and community outreach.
Bottcher, Robert W
2003-06-01
Air quality affects everyone. Some people are affected by air quality impacts, regulations, and technological developments in several ways. Stakeholders include the medical community, ecologists, government regulators, industries, technology providers, academic professionals, concerned citizens, the news media, and elected officials. Each of these groups may perceive problems and opportunities differently, but all need access to information as it is developed. The diversity and complexity of air quality problems contribute to the challenges faced by extension and outreach professionals who must communicate with stakeholders having diverse backgrounds. Gases, particulates, biological aerosols, pathogens, and odors all require expensive and relatively complex technology to measure and control. Economic constraints affect the ability of regulators and others to measure air quality, and industry and others to control it. To address these challenges, while communicating air quality research results and concepts to stakeholders, three areas of information needs are evident. (1) A basic understanding of the fundamental concepts regarding air pollutants and their measurement and control is needed by all stakeholders; the Extension Specialist, to be effective, must help people move some distance up the learning curve. (2) Each problem or set of problems must be reasonably well defined since comprehensive solution of all problems simultaneously may not be feasible; for instance, the solution of an odor problem associated with animal production may not address atmospheric effects due to ammonia emissions. (3) The integrity of the communication process must be preserved by avoiding prejudice and protectionism; although stakeholders may seek to modify information to enhance their interests, extension and outreach professionals must be willing to present unwelcome information or admit to a lack of information. A solid grounding in fundamental concepts, careful and fair problem definition, and a resolute commitment to integrity and credibility will enable effective communication of air quality information to and among diverse stakeholders.
Quality circles and their potential application to rural health care in Papua New Guinea.
Cibulskis, R E; Edwards, K N
1993-06-01
A quality circle is a group of service providers who meet regularly to solve problems relating to the quality of their work. This is an example of bottom-up rather than top-down management which has found considerable success in the industries of the developed world. This article describes the principles which govern the operation of quality circles, the expected benefits and how best to introduce them. The problems relating to the provision of quality health care in rural areas and the potential application of the quality circle methodology are discussed.
Impact of poor-quality medicines in the 'developing' world.
Newton, Paul N; Green, Michael D; Fernández, Facundo M
2010-03-01
Since our ancestors began trading several millennia ago, counterfeit and substandard medicines have been a recurring problem, with history punctuated by crises in the supply of anti-microbials, such as fake cinchona bark in the 1600s and fake quinine in the 1800s. Unfortunately this problem persists, in particular afflicting unsuspecting patients in 'developing' countries. Poor-quality drugs are a vital (but neglected) public health problem. They contribute to a 'crevasse' between the enormous effort in therapeutic research and policy decisions and implementation of good-quality medicines. 2009 Elsevier Ltd. All rights reserved.
Impact of poor-quality medicines in the ‘developing’ world
Newton, Paul N.; Green, Michael D.; Fernández, Facundo M.
2010-01-01
Since our ancestors began trading several millennia ago, counterfeit and substandard medicines have been a recurring problem, with history punctuated by crises in the supply of anti-microbials, such as fake cinchona bark in the 1600s and fake quinine in the 1800s. Unfortunately this problem persists, in particular afflicting unsuspecting patients in ‘developing’ countries. Poor-quality drugs are a vital (but neglected) public health problem. They contribute to a ‘crevasse’ between the enormous effort in therapeutic research and policy decisions and implementation of good-quality medicines. PMID:20117849
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fischer, J
2004-03-15
This report summarizes the investigation of two active desiccant module (ADM) pilot site installations initiated in 2001. Both pilot installations were retrofits at existing facilities served by conventional heating, ventilating, and air-conditioning (HVAC) systems that had encountered frequent humidity control, indoor air quality (IAQ), and other operational problems. Each installation involved combining a SEMCO, Inc., ADM (as described in Fischer and Sand 2002) with a standard packaged rooftop unit built by the Trane Company. A direct digital control (DDC) system integral to the ADM performed the dual function of controlling the ADM/rooftop combination and facilitating data collection, trending, and remotemore » performance monitoring. The first installation involved providing preconditioned outdoor air to replace air exhausted from the large kitchen hood and bathrooms of a Hooters restaurant located in Rome, Georgia. This facility had previously added an additional rooftop unit in an attempt to achieve occupant comfort without success. The second involved conditioning the outdoor air delivered to each room of a wing of the Mountain Creek Inn at the Callaway Gardens resort. This hotel, designed in the ''motor lodge'' format with each room opening to the outdoors, is located in southwest Georgia. Controlling the space humidity always presented a serious challenge. Uncomfortable conditions and musty odors had caused many guests to request to move to other areas within the resort. This is the first field demonstration performed by Oak Ridge National Laboratory where significant energy savings, operating cost savings, and dramatically improved indoor environmental conditions can all be claimed as the results of a retrofit desiccant equipment field installation. The ADM/rooftop combination installed at the restaurant resulted in a reduction of about 34% in the electricity used by the building's air-conditioning system. This represents a reduction of approximately 15% in overall electrical energy consumption and a 12.5-kW reduction in peak demand. The cost of gas used for regeneration of the desiccant wheel over this period of time is estimated to be only $740, using a gas cost of $0.50 per therm--the summer rate in 2001. The estimated net savings is $5400 annually, resulting in a 1-2 year payback. It is likely that similar energy/cost savings were realized at the Callaway Gardens hotel. In this installation, however, a central plant supplied the chilled water serving fan coil units in the hotel wing retrofitted with the ADM, so it was not metered separately. Consequently, the owner could not provide actual energy consumption data specific to the facility. The energy and operating cost savings at both sites are directly attributable to higher cooling-season thermostat settings and decreased conventional system run times. These field installations were selected as an immediate and appropriate response to correct indoor humidity and fresh air ventilation problems being experienced by building occupants and owners, so no rigorous baseline-building vs. test-building energy use/operating cost savings results can be presented. The report presents several simulated comparisons between the ADM/roof HVAC approach and other equipment combinations, where both desiccant and conventional systems are modeled to provide comparable fresh air ventilation rates and indoor humidity levels. The results obtained from these simulations demonstrate convincingly the energy and operating cost savings obtainable with this hybrid desiccant/vapor-compression technology, verifying those actually seen at the pilot installations. The ADM approach is less expensive than conventional alternatives providing similar performance and indoor air quality and provides a very favorable payback (1 year or so) compared with oversized rooftop units that cannot be operated effectively with the necessary high outdoor air percentages.« less
Jitendra, Asha K; Petersen-Brown, Shawna; Lein, Amy E; Zaslofsky, Anne F; Kunkel, Amy K; Jung, Pyung-Gang; Egan, Andrea M
2015-01-01
This study examined the quality of the research base related to strategy instruction priming the underlying mathematical problem structure for students with learning disabilities and those at risk for mathematics difficulties. We evaluated the quality of methodological rigor of 18 group research studies using the criteria proposed by Gersten et al. and 10 single case design (SCD) research studies using criteria suggested by Horner et al. and the What Works Clearinghouse. Results indicated that 14 group design studies met the criteria for high-quality or acceptable research, whereas SCD studies did not meet the standards for an evidence-based practice. Based on these findings, strategy instruction priming the mathematics problem structure is considered an evidence-based practice using only group design methodological criteria. Implications for future research and for practice are discussed. © Hammill Institute on Disabilities 2013.
Johansen, Ragnhild; Melle, Ingrid; Iversen, Valentina Cabral; Hestad, Knut
2013-11-01
The quality of the therapeutic alliance is associated with engagement in- and thus important to the outcome of- treatment in schizophrenia. In non-psychotic disorders, general personality traits and individual patterns of interpersonal problems have been linked to the formation and quality of the therapeutic alliance. The role of these factors in relation to therapeutic alliance has not previously been explored in schizophrenia spectrum disorders. To investigate associations between personality traits, interpersonal problems and the quality of the therapeutic alliance in early schizophrenia spectrum disorders. Demographic and clinical characteristics including Positive and Negative Syndrome Scale (PANSS) scores were assessed in 42 patients. Personality traits and interpersonal problems were assessed with the NEO Five factor Inventory (NEO-FFI) and the circumplex model of the Inventory of Interpersonal Problems (IIP-64C). Therapeutic alliance was measured with the Working Alliance Inventory - short form (WAI-S). Patient WAI-S scores were predicted by IIP-64C Submissive/Hostile interpersonal problems, age and PANSS excitative symptoms. Therapist WAI-S scores were predicted by NEO-FFI Agreeableness and the PANSS insight item. Core traits of personality and dimensions of interpersonal problems are associated with both patients' and therapists' perceptions of the quality of the working alliance. Copyright © 2013 Elsevier Inc. All rights reserved.
Flanagan, Meghan R; Foster, Carolyn C; Schleyer, Anneliese; Peterson, Gene N; Mandell, Samuel P; Rudd, Kristina E; Joyner, Byron D; Payne, Thomas H
2016-02-01
House staff quality improvement projects are often not aligned with training institution priorities. House staff are the primary users of inpatient problem lists in academic medical centers, and list maintenance has significant patient safety and financial implications. Improvement of the problem list is an important objective for hospitals with electronic health records under the Meaningful Use program. House staff surveys were used to create an electronic problem list manager (PLM) tool enabling efficient problem list updating. Number of new problems added and house staff perceptions of the problem list were compared before and after PLM intervention. The PLM was used by 654 house staff after release. Surveys demonstrated increased problem list updating (P = .002; response rate 47%). Mean new problems added per day increased from 64 pre-PLM to 125 post-PLM (P < .001). This innovative project serves as a model for successful engagement of house staff in institutional quality and safety initiatives with tangible institutional benefits. Copyright © 2016 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Rescorla, Leslie; Achenbach, Thomas M.; Ivanova, Masha Y.; Dumenci, Levent; Almqvist, Fredrik; Bilenberg, Niels; Bird, Hector; Broberg, Anders; Dobrean, Anca; Dopfner, Manfred; Erol, Nese; Forns, Maria; Hannesdottir, Helga; Kanbayashi, Yasuko; Lambert, Michael C.; Leung, Patrick; Minaei, Asghar; Mulatu, Mesfin S.; Novik, Torunn S.; Oh, Kyung-Ja; Roussos, Alexandra; Sawyer, Michael; Simsek, Zeynep; Steinhausen, Hans-Christoph; Weintraub, Sheila; Metzke, Christa Winkler; Wolanczyk, Tomasz; Zilber, Nelly; Zukauskiene, Rita; Verhulst, Frank
2007-01-01
In this study, the authors compared ratings of behavioral and emotional problems and positive qualities on the Youth Self-Report (T. M. Achenbach & L. A. Rescorla, 2001) by adolescents in general population samples from 24 countries (N = 27,206). For problem scales, country effect sizes (ESs) ranged from 3% to 9%, whereas those for gender and age…
ERIC Educational Resources Information Center
Wieland, N.; Baker, B. L.
2010-01-01
Background: Children with intellectual disability (ID) have been found to be at an increased risk for developing behavioural problems. The purpose of this study was to examine the relationship between the marital domain, including marital quality and spousal support, and behaviour problems in children with and without ID. Methods: The relationship…
ERIC Educational Resources Information Center
Bailey, Bill D.
2011-01-01
Public undergraduate higher education institutions face a number of seemingly intractable problems. Among those problems are cost, accountability and access. The Malcolm Baldrige National Quality Award process is designed to help organization of any type address problems of organizational performance. This process has been used by manufacturing,…
ERIC Educational Resources Information Center
Rué, Joan; Font, Antoni; Cebrián, Gisela
2013-01-01
There is wide agreement that problem-based learning is a key strategy to promote individual abilities for "learning how to learn". This paper presents the main contributions that reflective journals and the problem-based learning approach can make to foster professional knowledge and quality learning in higher education. Thirty-six…
Morgan, Judith K; Shaw, Daniel S; Olino, Thomas M
2012-08-01
Whereas socialization influences in early childhood have been linked to children's emerging internalizing problems and prosocial behavior, relatively few studies have examined how NE might moderate such associations in both advantageous and maladaptive ways. Furthermore, more research is needed to evaluate the impact of sibling relationships as an influential socialization influence on these child outcomes. In the current study we examined how NE might differentially moderate the associations between quality of relationships with siblings and both internalizing problems and social skills at school entry. NE moderated the effects of positive and destructive sibling relationship quality on child internalizing problems. Specifically, for boys high on NE, more positive sibling relationship quality predicted fewer internalizing problems, but more destructive sibling conflict predicted more internalizing problems. NE also moderated the effects of destructive sibling conflict on child social skills. For boys high on NE, destructive sibling conflict predicted fewer social skills. Boys high on NE appear to show greater susceptibility to the effects of sibling socialization on child outcomes, relative to boys low on NE. The implications of these interactions are discussed with respect to differential susceptibility theory.
Shaw, Daniel S.; Olino, Thomas M.
2012-01-01
Whereas socialization influences in early childhood have been linked to children’s emerging internalizing problems and prosocial behavior, relatively few studies have examined how NE might moderate such associations in both advantageous and maladaptive ways. Furthermore, more research is needed to evaluate the impact of sibling relationships as an influential socialization influence on these child outcomes. In the current study we examined how NE might differentially moderate the associations between quality of relationships with siblings and both internalizing problems and social skills at school entry. NE moderated the effects of positive and destructive sibling relationship quality on child internalizing problems. Specifically, for boys high on NE, more positive sibling relationship quality predicted fewer internalizing problems, but more destructive sibling conflict predicted more internalizing problems. NE also moderated the effects of destructive sibling conflict on child social skills. For boys high on NE, destructive sibling conflict predicted fewer social skills. Boys high on NE appear to show greater susceptibility to the effects of sibling socialization on child outcomes, relative to boys low on NE. The implications of these interactions are discussed with respect to differential susceptibility theory. PMID:22366882
Quality Assurance and Continuous Improvement: A Case Study of the University of Bahrain
ERIC Educational Resources Information Center
Al-Alawi, Yaser; Al-Kaabi, Dheya; Rashdan, Suad; Al-Khaleefa, Lobna
2009-01-01
In recent years, Bahrain has taken serious actions to diversify its sources of income and solve major national problems such as unemployment. Through this process it discovered that one of the main factors for its economic problems was the quality of higher education on offer. This led to the creation of a national Quality Assurance Authority that…
Quality Criteria as the Innovative Development Vector of Higher Education
ERIC Educational Resources Information Center
Melnichuk, Marina; Varlamova, Alla
2015-01-01
The article deals with the problem of quality assessment in the field of higher education in Russia and the USA. The authors describe the solution of the problem in the modern period of reforms and globalization and the authors' analysis of the main quality assessment approaches is presented in the article. [For the complete Volume 13, Number 2…
Huang, Yunyu; Voorham, Jaco; Haaijer-Ruskamp, Flora M
2016-07-01
Details of data quality and how quality issues were solved have not been reported in published comparative effectiveness studies using electronic health record data. We developed a conceptual framework of data quality assessment and preprocessing and apply it to a study comparing angiotensin-converting enzyme inhibitors with angiotensin receptor blockerss on renal function decline in diabetes patients. The framework establishes a line of thought to identify and act on data issues. The core concept is to evaluate whether data are fit-for-use for research tasks. Possible quality problems are listed through specific signal detections, and verified whether they are true problems. Optimal solutions are selected for the identified problems. This framework can be used in observational studies to improve validity of results.
Magnée, Ellis H B; de Weert-van Oene, Gerdien H; Wijdeveld, Toon A G M; Coenen, Anton M L; de Jong, Cor A J
2015-09-01
Sleep problems and substance use are strongly linked. Sleep problems play a role in the etiology of substance use, but also may be a result of it. After detoxification, sleep problems may worsen leading to relapse. Nowadays, most substance dependence treatment programs aim at recovery rather than total abstinence, and in that view health-related quality of life (HRQL) is a relevant construct. This article describes the association between self-perceived sleep problems and HRQL in a naturalistic population of polydrug-using inpatients. At the start of treatment, 388 polydrug-using inpatients completed questionnaires concerning their sleep quality and HRQL. Three categories were established based on reported sleep problems: patients without sleep problems (21.6%), those with clinically relevant sleep problems (34.5%), and patients with sleep disorders (43.8%). Mean grades for quality of sleep were M = 7.3 (sd 1.7), M = 6.6 (sd 1.7) and M = 5.3 (sd 1.9) for the three categories, respectively. In addition, patients in the disorder category perceived a lower HRQL than those in the other categories. In the explanation of HRQL, both sleep problems and sleep disorders added significantly to the model when controlling for baseline characteristics. Our findings stress the need for clinicians to pay attention to the quality of sleep of recovering polydrug users, since this may play an important role in the recovery process. Monitoring sleep during treatment is advocated. This study adds to the knowledge about the way HRQL and sleep are related in a naturalistic sample of substance-dependent patients. © American Academy of Addiction Psychiatry.
Engle, Jennifer M.; McElwain, Nancy L.
2010-01-01
The presence and quality of friendships are posited to have developmental significance, yet little is known about the extent to which children without friends versus low-quality friendships compare on socioemotional adjustment. The current study utilized data from a subsample of 567 children (289 boys) participating in the NICHD Study of Early Child Care and Youth Development. Based on maternal reports at kindergarten, four friendship groups were formed: no friends, low quality, average quality, and high quality, and these groups were used to predict teacher-reported behavior problems and social skills concurrently (in kindergarten) and longitudinally (in first and third grade). Concurrently, low-quality friendships were associated with greater externalizing behavior, whereas high-quality friendships were associated with greater social skills. Longitudinally, having no friends in kindergarten was associated with higher levels of externalizing behavior for boys, but lower levels for girls. Children without friends also showed more internalizing problems at first grade. Lastly, having a high-quality friendship in kindergarten was associated with greater social skills in first and third grades, but only for boys. Results underscore high-quality friendship as a context for the development of social skills and indicate different trajectories of problem behavior for kindergarten children with no friends versus low-quality friendships. PMID:21822401
Assessment and mitigation of power quality problems for PUSPATI TRIGA Reactor (RTP)
NASA Astrophysics Data System (ADS)
Zakaria, Mohd Fazli; Ramachandaramurthy, Vigna K.
2017-01-01
An electrical power systems are exposed to different types of power quality disturbances. Investigation and monitoring of power quality are necessary to maintain accurate operation of sensitive equipment especially for nuclear installations. This paper will discuss the power quality problems observed at the electrical sources of PUSPATI TRIGA Reactor (RTP). Assessment of power quality requires the identification of any anomalous behavior on a power system, which adversely affects the normal operation of electrical or electronic equipment. A power quality assessment involves gathering data resources; analyzing the data (with reference to power quality standards) then, if problems exist, recommendation of mitigation techniques must be considered. Field power quality data is collected by power quality recorder and analyzed with reference to power quality standards. Normally the electrical power is supplied to the RTP via two sources in order to keep a good reliability where each of them is designed to carry the full load. The assessment of power quality during reactor operation was performed for both electrical sources. There were several disturbances such as voltage harmonics and flicker that exceeded the thresholds. To reduce these disturbances, mitigation techniques have been proposed, such as to install passive harmonic filters to reduce harmonic distortion, dynamic voltage restorer (DVR) to reduce voltage disturbances and isolate all sensitive and critical loads.
Stepfamily Relationship Quality and Children's Internalizing and Externalizing Problems.
Jensen, Todd M; Lippold, Melissa A; Mills-Koonce, Roger; Fosco, Gregory M
2017-03-07
The stepfamily literature is replete with between-group analyses by which youth residing in stepfamilies are compared to youth in other family structures across indicators of adjustment and well-being. Few longitudinal studies examine variation in stepfamily functioning to identify factors that promote the positive adjustment of stepchildren over time. Using a longitudinal sample of 191 stepchildren (56% female, mean age = 11.3 years), the current study examines the association between the relationship quality of three central stepfamily dyads (stepparent-child, parent-child, and stepcouple) and children's internalizing and externalizing problems concurrently and over time. Results from path analyses indicate that higher levels of parent-child affective quality are associated with lower levels of children's concurrent internalizing and externalizing problems at Wave 1. Higher levels of stepparent-child affective quality are associated with decreases in children's internalizing and externalizing problems at Wave 2 (6 months beyond baseline), even after controlling for children's internalizing and externalizing problems at Wave 1 and other covariates. The stepcouple relationship was not directly linked to youth outcomes. Our findings provide implications for future research and practice. © 2017 Family Process Institute.
Liu, Ping; Li, Guodong; Liu, Xinggao; Xiao, Long; Wang, Yalin; Yang, Chunhua; Gui, Weihua
2018-02-01
High quality control method is essential for the implementation of aircraft autopilot system. An optimal control problem model considering the safe aerodynamic envelop is therefore established to improve the control quality of aircraft flight level tracking. A novel non-uniform control vector parameterization (CVP) method with time grid refinement is then proposed for solving the optimal control problem. By introducing the Hilbert-Huang transform (HHT) analysis, an efficient time grid refinement approach is presented and an adaptive time grid is automatically obtained. With this refinement, the proposed method needs fewer optimization parameters to achieve better control quality when compared with uniform refinement CVP method, whereas the computational cost is lower. Two well-known flight level altitude tracking problems and one minimum time cost problem are tested as illustrations and the uniform refinement control vector parameterization method is adopted as the comparative base. Numerical results show that the proposed method achieves better performances in terms of optimization accuracy and computation cost; meanwhile, the control quality is efficiently improved. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.
Solving TSP problem with improved genetic algorithm
NASA Astrophysics Data System (ADS)
Fu, Chunhua; Zhang, Lijun; Wang, Xiaojing; Qiao, Liying
2018-05-01
The TSP is a typical NP problem. The optimization of vehicle routing problem (VRP) and city pipeline optimization can use TSP to solve; therefore it is very important to the optimization for solving TSP problem. The genetic algorithm (GA) is one of ideal methods in solving it. The standard genetic algorithm has some limitations. Improving the selection operator of genetic algorithm, and importing elite retention strategy can ensure the select operation of quality, In mutation operation, using the adaptive algorithm selection can improve the quality of search results and variation, after the chromosome evolved one-way evolution reverse operation is added which can make the offspring inherit gene of parental quality improvement opportunities, and improve the ability of searching the optimal solution algorithm.
Booker, Jordan A; Ollendick, Thomas H; Dunsmore, Julie C; Greene, Ross W
2016-05-01
Our objective in this study was to examine the moderating influence of parent-child relationship quality (as viewed by the child) on associations between conduct problems and treatment responses for children with oppositional defiant disorder (ODD). To date, few studies have considered children's perceptions of relationship quality with parents in clinical contexts even though extant studies show the importance of this factor in children's behavioral adjustment in non-clinical settings. In this study, 123 children (ages 7 - 14 years, 61.8% male, 83.7% white) who fulfilled DSM-IV criteria for ODD received one of two psychosocial treatments: Parent Management Training or Collaborative & Proactive Solutions. In an earlier study, both treatments were found to be effective and equivalent in treatment outcomes (Ollendick et al., in press). In the current study, pre-treatment maternal reports of conduct problems and pre-treatment child reports of relations with parents were used to predict outcomes in ODD symptoms and their severity following treatment. Elevated reports of children's conduct problems were associated with attenuated reductions in both ODD symptoms and their severity. Perceived relationship quality with parents moderated the ties between conduct problems and outcomes in ODD severity but not the number of symptoms. Mother reports of elevated conduct problems predicted attenuated treatment response only when children viewed relationship quality with their parents as poorer. When children viewed the relationship as higher quality, they did not show an attenuated treatment response, regardless of reported conduct problems. The current findings underscore the importance of children's perspectives in treatment response and reductions in externalizing child behaviors.
Complete identification and eventual prevention of urban water quality problems pose significant monitoring, "smart growth" and water quality management challenges. Uncontrolled increase of impervious surface area (roads, buildings, and parking lots) causes detrimental hydrologi...
Second-order polynomial model to solve the least-cost lumber grade mix problem
Urs Buehlmann; Xiaoqiu Zuo; R. Edward Thomas
2010-01-01
Material costs when cutting solid wood parts from hardwood lumber for secondary wood products manufacturing account for 20 to 50 percent of final product cost. These costs can be minimized by proper selection of the lumber quality used. The lumber quality selection problem is referred to as the least-cost lumber grade mix problem in the industry. The objective of this...
Environmental Impact Statement Space Shuttle Program, Vandenberg AFB, California. Supplement.
1983-07-01
area, will induce significant population growth and aggravate current housing and water availability problems . Six appendices offer more detailed...impacts have been reevaluated in light of recent changes in the p-ogram, research studies in problem areas, and newly- acquired knowledge of the...aggravate short-term problems concerning housing, and the quality and quantity of available water. x 7. PERMITS AND OTHER ENTITLEMENTS Air quality
Lake Erie Wastewater Management Study.
1982-09-01
quality problems, the causes of these problems, and a cost- effective strategy to improve Lake Erie’s water quality.Numerous questions remain...unanswered about the exact relationship between land use and water quality and about the effectiveness of the proposed management strategy. However, enough...Dr. Terry J. Logan of Ohio State University who wrote the biological availa- bility section and developed cost effectiveness of different Best
Six Sigma Approach to Improve Stripping Quality of Automotive Electronics Component – a case study
NASA Astrophysics Data System (ADS)
Razali, Noraini Mohd; Murni Mohamad Kadri, Siti; Con Ee, Toh
2018-03-01
Lacking of problem solving skill techniques and cooperation between support groups are the two obstacles that always been faced in actual production line. Inadequate detail analysis and inappropriate technique in solving the problem may cause the repeating issues which may give impact to the organization performance. This study utilizes a well-structured six sigma DMAIC with combination of other problem solving tools to solve product quality problem in manufacturing of automotive electronics component. The study is concentrated at the stripping process, a critical process steps with highest rejection rate that contribute to the scrap and rework performance. The detail analysis is conducted in the analysis phase to identify the actual root cause of the problem. Then several improvement activities are implemented and the results show that the rejection rate due to stripping defect decrease tremendously and the process capability index improved from 0.75 to 1.67. This results prove that the six sigma approach used to tackle the quality problem is substantially effective.
Domínguez, Ximena; Vitiello, Virginia E; Fuccillo, Janna M; Greenfield, Daryl B; Bulotsky-Shearer, Rebecca J
2011-04-01
Research suggests that promoting adaptive approaches to learning early in childhood may help close the gap between advantaged and disadvantaged children. Recent research has identified specific child-level and classroom-level variables that are significantly associated with preschoolers' approaches to learning. However, further research is needed to understand the interactive effects of these variables and determine whether classroom-level variables buffer the detrimental effects of child-level risk variables. Using a largely urban and minority sample (N=275) of preschool children, the present study examined the additive and interactive effects of children's context-specific problem behaviors and classroom process quality dimensions on children's approaches to learning. Teachers rated children's problem behavior and approaches to learning and independent assessors conducted classroom observations to assess process quality. Problem behaviors in structured learning situations and in peer and teacher interactions were found to negatively predict variance in approaches to learning. Classroom process quality domains did not independently predict variance in approaches to learning. Nonetheless, classroom process quality played an important role in these associations; high emotional support buffered the detrimental effects of problem behavior, whereas high instructional support exacerbated them. The findings of this study have important implications for classroom practices aimed at helping children who exhibit problem behaviors. Copyright © 2010 Society for the Study of School Psychology. Published by Elsevier Ltd. All rights reserved.
Dubois-Comtois, Karine; Bernier, Annie; Tarabulsy, George M; Cyr, Chantal; St-Laurent, Diane; Lanctôt, Anne-Sophie; St-Onge, Janie; Moss, Ellen; Béliveau, Marie-Julie
2015-10-01
This study investigated different environmental and contextual factors associated with maltreated children's adjustment in foster care. Participants included 83 children (52 boys), ages 1-7 years, and their foster caregivers. Quality of interaction with the foster caregiver was assessed from direct observation of a free-play situation; foster caregiver attachment state of mind and commitment toward the child were assessed using two interviews; disruptive behavior symptoms were reported by foster caregivers. Results showed that quality of interaction between foster caregivers and children were associated with behavior problems, such that higher-quality interactions were related to fewer externalizing and internalizing problems. Foster caregivers' state of mind and commitment were interrelated but not directly associated with behavior problems of foster children. Type of placement moderated the association between foster caregiver commitment and foster child behavior problems. Whereas greater foster caregiver commitment was associated with higher levels of adjustment for children in foster families (kin and non-kin), this was not the case in foster-to-adopt families. Finally, the associations between foster child behavior problems and history of maltreatment and placement related-risk conditions fell below significance after considering child age and quality of interaction with the foster caregiver. Findings underscore the crucial contribution of the foster caregiver-child relationship to fostering child adjustment and, thereby, have important implications for clinical services offered to this population. Copyright © 2015 Elsevier Ltd. All rights reserved.
Impact of problem finding on the quality of authentic open inquiry science research projects
NASA Astrophysics Data System (ADS)
Labanca, Frank
2008-11-01
Problem finding is a creative process whereby individuals develop original ideas for study. Secondary science students who successfully participate in authentic, novel, open inquiry studies must engage in problem finding to determine viable and suitable topics. This study examined problem finding strategies employed by students who successfully completed and presented the results of their open inquiry research at the 2007 Connecticut Science Fair and the 2007 International Science and Engineering Fair. A multicase qualitative study was framed through the lenses of creativity, inquiry strategies, and situated cognition learning theory. Data were triangulated by methods (interviews, document analysis, surveys) and sources (students, teachers, mentors, fair directors, documents). The data demonstrated that the quality of student projects was directly impacted by the quality of their problem finding. Effective problem finding was a result of students using resources from previous, specialized experiences. They had a positive self-concept and a temperament for both the creative and logical perspectives of science research. Successful problem finding was derived from an idiosyncratic, nonlinear, and flexible use and understanding of inquiry. Finally, problem finding was influenced and assisted by the community of practicing scientists, with whom the students had an exceptional ability to communicate effectively. As a result, there appears to be a juxtaposition of creative and logical/analytical thought for open inquiry that may not be present in other forms of inquiry. Instructional strategies are suggested for teachers of science research students to improve the quality of problem finding for their students and their subsequent research projects.
Sharpe, Tim; Farren, Paul; Howieson, Stirling; Tuohy, Paul; McQuillan, Jonathan
2015-07-21
The need to reduce carbon emissions and fuel poverty has led to increased building envelope air tightness, intended to reduce uncontrolled ventilation heat losses. Ventilation strategies in dwellings still allow the use of trickle ventilators in window frames for background ventilation. The extent to which this results in "healthy" Indoor Air Quality (IAQ) in recently constructed dwellings was a concern of regulators in Scotland. This paper describes research to explore this. First a review of literature was conducted, then data on occupant interactions with ventilation provisions (windows, doors, trickle vents) gathered through an interview-based survey of 200 recently constructed dwellings, and measurements made on a sample of 40 of these. The main measured parameter discussed here is CO2 concentration. It was concluded after the literature review that 1000 ppm absolute was a reasonable threshold to use for "adequate" ventilation. The occupant survey found that there was very little occupant interaction with the trickle ventilators e.g., in bedrooms 63% were always closed, 28% always open, and in only 9% of cases occupants intervened to make occasional adjustments. In the measured dwellings average bedroom CO2 levels of 1520 ppm during occupied (night time) hours were observed. Where windows were open the average bedroom CO2 levels were 972 ppm. With windows closed, the combination of "trickle ventilators open plus doors open" gave an average of 1021 ppm. "Trickle ventilators open" gave an average of 1571 ppm. All other combinations gave averages of 1550 to 2000 ppm. Ventilation rates and air change rates were estimated from measured CO2 levels, for all dwellings calculated ventilation rate was less than 8 L/s/p, in 42% of cases calculated air change rate was less than 0.5 ach. It was concluded that trickle ventilation as installed and used is ineffective in meeting desired ventilation rates, evidenced by high CO2 levels reported across the sampled dwellings. Potential implications of the results are discussed.
NASA Astrophysics Data System (ADS)
Shrubsole, C.; Ridley, I.; Biddulph, P.; Milner, J.; Vardoulakis, S.; Ucci, M.; Wilkinson, P.; Chalabi, Z.; Davies, M.
2012-12-01
Simulations using CONTAM (a validated multi-zone indoor air quality (IAQ) model) are employed to predict indoor exposure to PM2.5 in London dwellings in both the present day housing stock and the same stock following energy efficient refurbishments to meet greenhouse gas emissions reduction targets for 2050. We modelled interventions that would contribute to the achievement of these targets by reducing the permeability of the dwellings to 3 m3 m-2 h-1 at 50 Pa, combined with the introduction of mechanical ventilation and heat recovery (MVHR) systems. It is assumed that the current mean outdoor PM2.5 concentration of 13 μg m-3 decreased to 9 μg m-3 by 2050 due to emission control policies. Our primary finding was that installation of (assumed perfectly functioning) MVHR systems with permeability reduction are associated with appreciable reductions in PM2.5 exposure in both smoking and non-smoking dwellings. Modelling of the future scenario for non-smoking dwellings show a reduction in annual average indoor exposure to PM2.5 of 18.8 μg m-3 (from 28.4 to 9.6 μg m-3) for a typical household member. Also of interest is that a larger reduction of 42.6 μg m-3 (from 60.5 to 17.9 μg m-3) was shown for members exposed primarily to cooking-related particle emissions in the kitchen (cooks). Reductions in envelope permeability without mechanical ventilation produced increases in indoor PM2.5 concentrations; 5.4 μg m-3 for typical household members and 9.8 μg m-3 for cooks. These estimates of changes in PM2.5 exposure are sensitive to assumptions about occupant behaviour, ventilation system usage and the distributions of input variables (±72% for non-smoking and ±107% in smoking residences). However, if realised, they would result in significant health benefits.
Impact of financial burden of cancer on survivors' quality of life.
Fenn, Kathleen M; Evans, Suzanne B; McCorkle, Ruth; DiGiovanna, Michael P; Pusztai, Lajos; Sanft, Tara; Hofstatter, Erin W; Killelea, Brigid K; Knobf, M Tish; Lannin, Donald R; Abu-Khalaf, Maysa; Horowitz, Nina R; Chagpar, Anees B
2014-09-01
Little is known about the relationship between the financial burden of cancer and the physical and emotional health of cancer survivors. We examined the association between financial problems caused by cancer and reported quality of life in a population-based sample of patients with cancer. Data from the 2010 National Health Interview Survey (NHIS) were analyzed. A multivariable regression model was used to examine the relationship between the degree to which cancer caused financial problems and the patients' reported quality of life. Of 2,108 patients who answered the survey question, "To what degree has cancer caused financial problems for you and your family?," 8.6% reported "a lot," whereas 69.6% reported "not at all." Patients who reported "a lot" of financial problems as a result of cancer care costs were more likely to rate their physical health (18.6% v 4.3%, P < .001), mental health (8.3% v 1.8%, P < .001), and satisfaction with social activities and relationships (11.8% v 3.6%, P < .001) as poor compared to those with no financial hardship. On multivariable analysis controlling for all of the significant covariates on bivariate analysis, the degree to which cancer caused financial problems was the strongest independent predictor of quality of life. Patients who reported that cancer caused "a lot" of financial problems were four times less likely to rate their quality of life as "excellent," "very good," or "good" (odds ratio = 0.24; 95% CI, 0.14 to 0.40; P < .001). Increased financial burden asa result of cancer care costs is the strongest independent predictor of poor quality of life among cancer survivors. Copyright © 2014 by American Society of Clinical Oncology.
Scherrer, Jeffrey F; Xian, Hong; Shah, Kamini R; Volberg, Rachel; Slutske, Wendy; Eisen, Seth A
2005-06-01
Problem and pathological gambling are associated with many impairments in quality of life, including financial, family, legal, and social problems. Gambling disorders commonly co-occur with other psychiatric disorders, such as alcoholism and depression. Although these consequences and correlates have been reported, little is known about the health-related functional impairment associated with gambling. To model differences in the health-related quality of life (HRQoL) among non-problem gamblers, problem gamblers, and pathological gamblers after controlling for lifetime co-occurring substance use disorders, psychiatric disorders, sociodemographics, and genetic and family environmental influences. Cohort and co-twin studies. Nationally distributed community sample. Male twin members of the Vietnam Era Twin Registry: 53 pathological gamblers, 270 subclinical problem gamblers, and 1346 non-problem gamblers (controls). We obtained HRQoL data, via the 8-Item Short-Form Health Survey, from all participants. Data from a subset of twin pairs discordant for gambling behavior was used to control for genetic and family environmental effects on HRQoL and problem gambling. Main Outcome Measure Health-related quality of life. Results from adjusted logistic regression analyses suggest little difference across groups in the physical domains of the health survey; however, for each mental health domain, pathological gamblers had lower HRQoL scores than problem gamblers (P<.05), who in turn had lower scores than non-problem gamblers (P<.05). After controlling for genes and family environment, no significant differences existed between the non-problem gambling twins and their problem or pathological gambling brothers, but adjusted co-twin analyses resulted in statistically significant differences in 4 of 8 subscales. Pathological and problem gambling are associated with significant decrements in HRQoL. This association is partly explained by genetic and family environmental effects and by lifetime co-occurring substance use disorders. Implications for clinicians, health care utilization, and public health issues are discussed.
Rumination decreases parental problem-solving effectiveness in dysphoric postnatal mothers.
O'Mahen, Heather A; Boyd, Alex; Gashe, Caroline
2015-06-01
Postnatal depression is associated with poorer parenting quality, but there are few studies examining maternal-specific cognitive processes that may impact on parenting quality. In this study, we examined the impact of rumination on parental problem-solving effectiveness in dysphoric and non-dysphoric postnatal mothers. Fifty-nine mothers with a infant aged 12 months and under, 20 of whom had a Beck Depression Score II (BDI-II) score ≥ 14, and 39 who scored less than 14 on the BDI-II were randomly assigned to either a rumination or distraction condition. Problem-solving effectiveness was assessed post-induction with the "Postnatal Parental Problem-Solving Task" (PPST), which was adapted from the Means Ends Problem-solving task. Parental problem-solving confidence was also assessed. Dysphoric ruminating mothers exhibited poorer problem-solving effectiveness and poorer confidence regarding their problem-solving compared to dysphoric distracting, non-dysphoric distracting, and non-dysphoric ruminating mothers. A self-report measure of depressed mood was used. Rumination may be a key mechanism associated with both depressive mood and maternal parenting quality during the postnatal period. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.
[Relations between problems on sleeping and suicidal behaviors in middle school students].
Chen, Jing; Wan, Yuhui; Sun, Ying; Tao, Fangbiao
2014-02-01
To understand the epidemiological characteristics and possible associations between sleeping problems and suicidal behaviors among middle school students. A total of 13 817 middle school students were selected in Shenyang,Xinxiang, Chongqing and Guangzhou cities and cluster sampling method was used. Questionnaires would include information on demographics, quality of sleep, psychopathological status and suicidal behaviors. Pittsburgh Sleep Quality index (PSQI) and Adolescent Multidimensional Sub-health Questionnaire (MSQA) were used to assess the quality of sleep and psychosomatic symptoms, respectively. Rates on sleeping problems and suicidal behaviors were compared in students with specific characteristics. Effects related to sleeping problems and suicidal behaviors were analyzed, using the multivariate logistic regression model. The overall prevalence of problems related to sleeping among middle school students was 26.5%. 28.2% of the girls and 35.2% of senior students reported as having more sleeping problems. Rates on suicide related ideation, planning and attempts were 16.6%, 9.6% and 4.7% , respectively. Girls reported more suicide ideation than boys. However, no gender differences were found in suicide planning or attempted suicide. It also suggested that the incidence of the suicidal behavior among students with sleeping problems was significantly higher than students without sleeping problems. Data from Multivariable logistic regression analysis showed that sleeping problems appeared as independent risk factors on suicidal behavior. Higher PSQI scores seemed coincide with the increased risk of suicidal behaviors. Students having sleeping time less than 5 hours per day showed higher risk of suicidal behaviors. Problems on sleeping seemed a strong risk factor for suicidal behaviors among middle school students. Improvement on the quality of sleep and reasonable arrangement of sleeping time could help prevent related suicidal behaviors among middle school students.
Technical Report, Onondaga Lake, New York, Main Report
1992-01-01
growth . Section 3 of this report will expand upon the specific water quality problems. EXISTING CONDITIONS Page 23 Table V - Comparison of Current...This technical report on Ononidaga Lake, New York has compi led existing data to determine which water quality and enviromental enhancements are... bacteria is a problem during storm events causing contravention of the State swimming standards. The source of the problem has been identified as the
1983-07-01
problems . Six appendices offer more detailed environmental assessments for the key issues of air quality impacts, inadvertent weather modification...research studies in problem areas, and newly- acquired knowledge of the affected environment. The physical, chemi- cal, biological, and...Shuttle program, in conjunction with other projects within the county, will aggravate short-tenm problems concerning housing, and the quality and quantity
The Quality of High School Students' Problem Solving from an Expertise Development Perspective
ERIC Educational Resources Information Center
Elvira, Quincy; Imants, Jeroen; deMaeyer, Sven; Segers, Mien
2015-01-01
The ability to solve problems is a key skill and is essential to our day-to-day lives, at home, at school and at work. The present study explores the quality of managerial problem-solving of participants who are in secondary education. We studied 10th, 11th, and 12th graders following a business track in the Netherlands. Participants were asked to…
A network for continuous monitoring of water quality in the Sabine River basin, Texas and Louisiana
Blakey, J.F.; Skinner, P.W.
1973-01-01
Level I operations at a proposed site would monitor current and potential problems, water-quality changes in subreaches of streams, and water-quality trends in time and place. Level II operations would monitor current or potential problems only. An optimum system would require Level I operations at all nine stations. A minimum system would require Level II operations at most of the stations.
Study of weld quality real-time monitoring system for auto-body assembly
NASA Astrophysics Data System (ADS)
Xu, Jun; Li, Yong-Bing; Chen, Guan-Long
2005-12-01
Resistance spot welding (RSW) is widely used for the auto-body assembly in automotive industry. But RSW suffers from a major problem of inconsistent quality from weld to weld. The major problem is the complexity of the basic process that may involve material coatings, electrode force, electrode wear, fit up, etc. Therefore weld quality assurance is still a big challenge and goal. Electrode displacement has proved to be a particularly useful signal which correlates well with weld quality. This paper introduces a novel auto-body spot weld quality monitoring system which uses electrode displacement as the quality parameter. This system chooses the latest laser displacement sensor with high resolution to measure the real-time electrode displacement. It solves the interference problem of sensor mounting by designing special fixture, and can be successfully applied on the portable welding machine. It is capable of evaluating weld quality and making diagnosis of process variations such as surface asperities, shunting, worn electrode and weld expansion with real-time electrode displacement. As proved by application in the workshop, the monitoring system has good stability and reliability, and is qualified for monitoring weld quality in process.
Fact Sheet on Avoiding Indoor Air Quality Problems During Flood Cleanup
This fact sheet discusses problems caused by microbial growth, and other effects of flooding, on indoor air quality and the steps you can take to lessen these effects. This focuses on residential flood cleanup, but it applies to other building types.
E-therapy for mental health problems: a systematic review.
Postel, Marloes G; de Haan, Hein A; De Jong, Cor A J
2008-09-01
The widespread availability of the Internet offers opportunities for improving access to therapy for people with mental health problems. There is a seemingly infinite supply of Internet-based interventions available on the World Wide Web. The aim of the present study is to systematically assess the methodological quality of randomized controlled trials (RCTs) concerning e-therapy for mental health problems. Two reviewers independently assessed the methodological quality of the RCTs, based on a list of criteria for the methodological quality assessment as recommended by the Cochrane Back Review Group. The search yielded 14 papers that reported RCTs concerning e-therapy for mental-health problems. The methodological quality of studies included in this review was generally low. It is concluded that e-therapy may turn out to be an appropriate therapeutic entity, but the evidence needs to be more convincing. Recommendations are made concerning the method of reporting RCTs and the need to add some content items to an e-therapy study.
Visualizing the Quality of Vectur Features - a Proposal for Cadastral Maps
NASA Astrophysics Data System (ADS)
Navratil, G.; Leopoldseder, V.
2017-09-01
A well-known problem of geographical information is the communication of the quality level. It can be either done verbally / numerically or it can be done graphically. The graphical form is especially useful if the quality has a spatial variation because the spatial distribution is visualized as well. The problem of spatial variation of quality is an issue for cadastral maps. Non-experts cannot determine the quality at a specific location. Therefore a visual representation was tested for the Austrian cadastre. A map sheet was redesigned to give some indication of cadastral quality and presented to both experts and non-experts. The paper presents the result of the interviews.
Analysis of Station Quality Issues from EarthScope's Transportable Array
NASA Astrophysics Data System (ADS)
Pfeifer, C.; Barstow, N.; Busby, R.; Hafner, K.
2008-12-01
160 of the first 400 Earthscope USARRY transportable array (TA) stations have completed their first two-year deployment and are being moved to their next locations. Over the past 4 years the majority of stations have run with few interruptions in the transfer of real time data to the Array Network Facility (ANF) at the Univ of CA San Diego and near real time data to the IRIS Data Management System (DMS). The combination of telemetered data and dedicated people reviewing the waveforms and state of health data have revealed several conditions that can affect the data quality or cause loss of data. The data problems fall into three broad categories; station power, equipment malfunction, and communication failures. Station power issues have been implicated in several types of noise seen in the seismic data (as well as causing station failures and resultant data gaps). The most common type of equipment problem that has been found to degrade data quality is caused by sensor problems, and has affected all 3 types of sensors used in the TA to varying degrees. While communication problems can cause real time data loss, they do not cause a degradation of the quality of the data, and any gaps in the real time data due solely to communications problems are filled in later with the continuous data recorded to disk at each TA station. Over the past 4 years the TA team has recognized a number of noise sources and have made several design changes to minimize the effects on data quality. Design/procedural changes include: stopping water incursion into the stations, power conditioning, changing mass re-center voltage thresholds. Figures that demonstrate examples are provided. Changes have created better data quality and improved the station performance. Vigilance and deployment of service teams to reestablish communications, replace noisy sensors, and troubleshoot problems is also key to maintaining the high-quality TA network.
[Quality assessment in anesthesia].
Kupperwasser, B
1996-01-01
Quality assessment (assurance/improvement) is the set of methods used to measure and improve the delivered care and the department's performance against pre-established criteria or standards. The four stages of the self-maintained quality assessment cycle are: problem identification, problem analysis, problem correction and evaluation of corrective actions. Quality assessment is a measurable entity for which it is necessary to define and calibrate measurement parameters (indicators) from available data gathered from the hospital anaesthesia environment. Problem identification comes from the accumulation of indicators. There are four types of quality indicators: structure, process, outcome and sentinel indicators. The latter signal a quality defect, are independent of outcomes, are easier to analyse by statistical methods and closely related to processes and main targets of quality improvement. The three types of methods to analyse the problems (indicators) are: peer review, quantitative methods and risks management techniques. Peer review is performed by qualified anaesthesiologists. To improve its validity, the review process should be explicited and conclusions based on standards of practice and literature references. The quantitative methods are statistical analyses applied to the collected data and presented in a graphic format (histogram, Pareto diagram, control charts). The risks management techniques include: a) critical incident analysis establishing an objective relationship between a 'critical' event and the associated human behaviours; b) system accident analysis, based on the fact that accidents continue to occur despite safety systems and sophisticated technologies, checks of all the process components leading to the impredictable outcome and not just the human factors; c) cause-effect diagrams facilitate the problem analysis in reducing its causes to four fundamental components (persons, regulations, equipment, process). Definition and implementation of corrective measures, based on the findings of the two previous stages, are the third step of the evaluation cycle. The Hawthorne effect is an outcome improvement, before the implementation of any corrective actions. Verification of the implemented actions is the final and mandatory step closing the evaluation cycle.
42 CFR 480.101 - Scope and definitions.
Code of Federal Regulations, 2011 CFR
2011-10-01
... (CONTINUED) QUALITY IMPROVEMENT ORGANIZATIONS ACQUISITION, PROTECTION, AND DISCLOSURE OF QUALITY IMPROVEMENT ORGANIZATION REVIEW INFORMATION Utilization and Quality Control Quality Improvement Organizations (QIOs... of the problem and follow-up. Quality review study information means all documentation related to the...
Toprak Celenay, Seyda; Anaforoglu Kulunkoglu, Bahar; Yasa, Mustafa Ertugrul; Sahbaz Pirincci, Cansu; Un Yildirim, Necmiye; Kucuksahin, Orhan; Ugurlu, Fatma Gulcin; Akkus, Selami
2017-11-01
This study aimed to compare the effectiveness of a 6-week combined exercise program with and without connective tissue massage (CTM) on pain, fatigue, sleep problem, health status, and quality of life in patients with fibromyalgia syndrome (FMS). Patients were randomly allocated into Exercise (n = 20) and Exercise + CTM (n = 20) groups. The exercise program with and without CTM was carried out 2 days a week for 6 weeks. Pain, fatigue, sleep problem with Visual Analog Scales, health status with Fibromyalgia Impact Questionnaire (FIQ), and quality of life with Short Form-36 were evaluated. After the program, pain, fatigue and sleep problem reduced, health status (except of the scores of FIQ-1 and FIQ-10), physical functioning, role limitations due to physical health, bodily pain, role limitations due to emotional health, vitality, and general health perceptions parameters related to quality of life improved in the Exercise group, (P < 0.05). In the Exercise + CTM group, pain, fatigue and sleep problem decreased, health status and quality of life improved (P < 0.05). Pain, fatigue, sleep problem, and role limitations due to physical health improved in the Exercise + CTM group in comparison to the Exercise group (P < 0.05). The study suggested that exercises with and without CTM might be effective for decreasing pain, fatigue and sleep problem whereas increasing health status and quality of life in patients with FMS. However, exercises with CTM might be superior in improving pain, fatigue, sleep problem, and role limitations due to physical health compared to exercise alone.
Purba, Fredrick Dermawan; Hunfeld, Joke A M; Iskandarsyah, Aulia; Fitriana, Titi Sahidah; Sadarjoen, Sawitri S; Passchier, Jan; Busschbach, Jan J V
2017-05-01
In valuing health states using generic questionnaires such as EQ-5D, there are unrevealed issues with the quality of the data collection. The aims were to describe the problems encountered during valuation and to evaluate a quality control report and subsequent retraining of interviewers in improving this valuation. Data from the first 266 respondents in an EQ-5D-5L valuation study were used. Interviewers were trained and answered questions regarding problems during these initial interviews. Thematic analysis was used, and individual feedback was provided. After completion of 98 interviews, a first quantitative quality control (QC) report was generated, followed by a 1-day retraining program. Subsequently individual feedback was also given on the basis of follow-up QCs. The Wilcoxon signed-rank test was used to assess improvements based on 7 indicators of quality as identified in the first QC and the QC conducted after a further 168 interviews. Interviewers encountered problems in recruiting respondents. Solutions provided were: optimization of the time of interview, the use of broader networks and the use of different scripts to explain the project's goals to respondents. For problems in interviewing process, solutions applied were: developing the technical and personal skills of the interviewers and stimulating the respondents' thought processes. There were also technical problems related to hardware, software and internet connections. There was an improvement in all 7 indicators of quality after the second QC. Training before and during a study, and individual feedback on the basis of a quantitative QC, can increase the validity of values obtained from generic questionnaires.
A New Model for Solving Time-Cost-Quality Trade-Off Problems in Construction
Fu, Fang; Zhang, Tao
2016-01-01
A poor quality affects project makespan and its total costs negatively, but it can be recovered by repair works during construction. We construct a new non-linear programming model based on the classic multi-mode resource constrained project scheduling problem considering repair works. In order to obtain satisfactory quality without a high increase of project cost, the objective is to minimize total quality cost which consists of the prevention cost and failure cost according to Quality-Cost Analysis. A binary dependent normal distribution function is adopted to describe the activity quality; Cumulative quality is defined to determine whether to initiate repair works, according to the different relationships among activity qualities, namely, the coordinative and precedence relationship. Furthermore, a shuffled frog-leaping algorithm is developed to solve this discrete trade-off problem based on an adaptive serial schedule generation scheme and adjusted activity list. In the program of the algorithm, the frog-leaping progress combines the crossover operator of genetic algorithm and a permutation-based local search. Finally, an example of a construction project for a framed railway overpass is provided to examine the algorithm performance, and it assist in decision making to search for the appropriate makespan and quality threshold with minimal cost. PMID:27911939
Problem Solving Teams in a Total Quality Management Environment.
ERIC Educational Resources Information Center
Towler, Constance F.
1993-01-01
Outlines the problem-solving team training process used at Harvard University (Massachusetts), including the size and formation of teams, roles, and time commitment. Components of the process are explained, including introduction to Total Quality Management (TQM), customer satisfaction, meeting management, Parker Team Player Survey, interactive…
Aspects of Girls' Friendships: Practice Implications for Internalizing Problems
ERIC Educational Resources Information Center
Ralph, Leslie E. R.; Epkins, Catherine C.
2015-01-01
Background: Children's friendship quality is a particularly important risk or protective factor for internalizing problems and loneliness. Past research indicates that relationship satisfaction is related to perceived similarity; however, it is unclear whether this relation is seen in girls' friendship quality and whether this relation is…
Petzold, Thomas; Steinwitz, Adrienne; Schmitt, Jochen; Eberlein-Gonska, Maria
2013-01-01
Obligatory external quality assurance is an established method used to ensure the quality of inpatient care in Germany. The comprehensive approach is unique in international comparison. In addition to the statutory requirement, the health insurance funds require this form of external quality control in order to foster quality-based competition between hospitals. Ever since its introduction, healthcare providers have scrutinised the effects of the mandatory use of this survey. The study was based on all patients in the University Hospital Dresden, for whom a quality assurance sheet (n = 45,639) had to be recorded between 2003 and 2011. The documentation of these sheets was carried out by specially trained personnel. For each performance area, the duration of the documentation quality sheets was assessed, and a descriptive analysis of all quality assurance sheets was conducted. In the presence of statistical significance the so-called "Structured Dialogues" were analysed. Over the whole period, 167 statistically noticeable problems occurred. Nine of these have been rated as noticeable problems in medical quality by the specialised working groups of the project office quality assurance (PGSQS) at the Saxon State Medical Association (SLÄK). The remaining 158 statistical anomalies included 25 documentation errors; 96 were classified as statistically significant, and only 37 were marked to indicate that re-observation by the PGSQS was required. The total effort estimate for the documentation of quality assurance sheets was approximately 1,420 working days in the observation period. As far as the quality of patient care is concerned, the results can be considered positive because only a small number of quality indicators indicate noticeable qualitative problems. This statement is based primarily on the comparison of the groups of Saxony and Germany, which are included in the quality report of external quality assurance in accordance with sect. 137 SGB V. The majority of noticeable statistical problems were due to documentation errors. Other noticeable statistical problems that are medically indicated, but without effect on the extramural care to patients, recurrently occur with the respective quality indicators. Examples include the postoperative mobility indicators of the implementation of endoprostheses which cannot be used to draw conclusions about patient outcomes. Information on the quality of life as well as the post-hospital course of disease would be important in this context, but is still lacking. The use of external quality assurance data in accordance with sect. 137 SGB V for evaluation research has so far been handled quite restrictively. Thus, in-depth analyses on the quality of treatment cannot be derived. Copyright © 2013. Published by Elsevier GmbH.
NASA Technical Reports Server (NTRS)
Vajingortin, L. D.; Roisman, W. P.
1991-01-01
The problem of ensuring the required quality of products and/or technological processes often becomes more difficult due to the fact that there is not general theory of determining the optimal sets of value of the primary factors, i.e., of the output parameters of the parts and units comprising an object and ensuring the correspondence of the object's parameters to the quality requirements. This is the main reason for the amount of time taken to finish complex vital article. To create this theory, one has to overcome a number of difficulties and to solve the following tasks: the creation of reliable and stable mathematical models showing the influence of the primary factors on the output parameters; finding a new technique of assigning tolerances for primary factors with regard to economical, technological, and other criteria, the technique being based on the solution of the main problem; well reasoned assignment of nominal values for primary factors which serve as the basis for creating tolerances. Each of the above listed tasks is of independent importance. An attempt is made to give solutions for this problem. The above problem dealing with quality ensuring an mathematically formalized aspect is called the multiple inverse problem.
Sandler, Irwin N; Wheeler, Lorey A; Braver, Sanford L
2013-12-01
The current study examined the associations between child mental health problems and the quality of maternal and paternal parenting, and how these associations were moderated by three contextual factors: quality of parenting by the other parent, interparental conflict, and the number of overnights parents had with the child. Data for the current study came from a sample of divorcing families who are in high legal conflict over developing or maintaining a parenting plan following divorce. Analyses revealed that the associations between child mental health problems and positive maternal and paternal parenting were moderated by the quality of parenting provided by the other parent and by the number of overnights children spent with parents, but not by the level of interparental conflict. When parenting by the other parent and number of overnights were considered together in the same model, only number of overnights moderated the relations between parenting and child-behavior problems. The results support the proposition that the well-being of children in high-conflict divorcing families is better when they spend adequate time with at least one parent who provides high-quality parenting.
Sandler, Irwin N.; Wheeler, Lorey A.; Braver, Sanford L.
2013-01-01
The current study examined the associations between child mental health problems and the quality of maternal and paternal parenting, and how these associations were moderated by three contextual factors, quality of parenting by the other parent, interparental conflict, and the number of overnights parents had with the child. Data for the current study come from a sample of divorcing families who are in high legal conflict over developing or maintaining a parenting plan following divorce. Analyses revealed that the associations between child mental health problems and positive maternal and paternal parenting were moderated by the quality of parenting provided by the other parent and by the number of overnights children spent with parents, but not by the level of interparental conflict. When both parenting by the other parent and number of overnights were considered in the same model, only number of overnights moderated the relations between parenting and child behavior problems. The results support the proposition that the well-being of children in high conflict divorcing families is better when they spend adequate time with at least one parent who provides high quality parenting. PMID:24098960