Sample records for quality monitor system

  1. Portable water quality monitoring system

    NASA Astrophysics Data System (ADS)

    Nizar, N. B.; Ong, N. R.; Aziz, M. H. A.; Alcain, J. B.; Haimi, W. M. W. N.; Sauli, Z.

    2017-09-01

    Portable water quality monitoring system was a developed system that tested varied samples of water by using different sensors and provided the specific readings to the user via short message service (SMS) based on the conditions of the water itself. In this water quality monitoring system, the processing part was based on a microcontroller instead of Lead and Copper Rule (LCR) machines to receive the results. By using four main sensors, this system obtained the readings based on the detection of the sensors, respectively. Therefore, users can receive the readings through SMS because there was a connection between Arduino Uno and GSM Module. This system was designed to be portable so that it would be convenient for users to carry it anywhere and everywhere they wanted to since the processor used is smaller in size compared to the LCR machines. It was also developed to ease the user to monitor and control the water quality. However, the ranges of the sensors' detection still a limitation in this study.

  2. Quality monitored distributed voting system

    DOEpatents

    Skogmo, David

    1997-01-01

    A quality monitoring system can detect certain system faults and fraud attempts in a distributed voting system. The system uses decoy voters to cast predetermined check ballots. Absent check ballots can indicate system faults. Altered check ballots can indicate attempts at counterfeiting votes. The system can also cast check ballots at predetermined times to provide another check on the distributed voting system.

  3. Quality monitored distributed voting system

    DOEpatents

    Skogmo, D.

    1997-03-18

    A quality monitoring system can detect certain system faults and fraud attempts in a distributed voting system. The system uses decoy voters to cast predetermined check ballots. Absent check ballots can indicate system faults. Altered check ballots can indicate attempts at counterfeiting votes. The system can also cast check ballots at predetermined times to provide another check on the distributed voting system. 6 figs.

  4. The immunization data quality audit: verifying the quality and consistency of immunization monitoring systems.

    PubMed Central

    Ronveaux, O.; Rickert, D.; Hadler, S.; Groom, H.; Lloyd, J.; Bchir, A.; Birmingham, M.

    2005-01-01

    OBJECTIVE: To evaluate the consistency and quality of immunization monitoring systems in 27 countries during 2002-03 using standardized data quality audits (DQAs) that had been launched within the framework of the Global Alliance for Vaccines and Immunization. METHODS: The consistency of reporting systems was estimated by determining the proportion of third doses of diphtheria-tetanuspertussis (DTP-3) vaccine reported as being administered that could be verified by written documentation at health facilities and districts. The quality of monitoring systems was measured using quality indices for different components of the monitoring systems. These indices were applied to each level of the health service (health unit, district and national). FINDINGS: The proportion of verified DTP-3 doses was lower than 85% in 16 countries. Difficulties in verifying the doses administered often arose at the peripheral level of the health service, usually as the result of discrepancies in information between health units and their corresponding districts or because completed recording forms were not available from health units. All countries had weaknesses in their monitoring systems; these included the inconsistent use of monitoring charts; inadequate monitoring of vaccine stocks, injection supplies and adverse events; unsafe computer practices; and poor monitoring of completeness and timeliness of reporting. CONCLUSION: Inconsistencies in immunization data occur in many countries, hampering their ability to manage their immunization programmes. Countries should use these findings to strengthen monitoring systems so that data can reliably guide programme activities. The DQA is an innovative tool that provides a way to independently assess the quality of immunization monitoring systems at all levels of a health service and serves as a point of entry to make improvements. It provides a useful example for other global health initiatives. PMID:16175824

  5. Winter wheat quality monitoring and forecasting system based on remote sensing and environmental factors

    NASA Astrophysics Data System (ADS)

    Haiyang, Yu; Yanmei, Liu; Guijun, Yang; Xiaodong, Yang; Dong, Ren; Chenwei, Nie

    2014-03-01

    To achieve dynamic winter wheat quality monitoring and forecasting in larger scale regions, the objective of this study was to design and develop a winter wheat quality monitoring and forecasting system by using a remote sensing index and environmental factors. The winter wheat quality trend was forecasted before the harvest and quality was monitored after the harvest, respectively. The traditional quality-vegetation index from remote sensing monitoring and forecasting models were improved. Combining with latitude information, the vegetation index was used to estimate agronomy parameters which were related with winter wheat quality in the early stages for forecasting the quality trend. A combination of rainfall in May, temperature in May, illumination at later May, the soil available nitrogen content and other environmental factors established the quality monitoring model. Compared with a simple quality-vegetation index, the remote sensing monitoring and forecasting model used in this system get greatly improved accuracy. Winter wheat quality was monitored and forecasted based on the above models, and this system was completed based on WebGIS technology. Finally, in 2010 the operation process of winter wheat quality monitoring system was presented in Beijing, the monitoring and forecasting results was outputted as thematic maps.

  6. 77 FR 18709 - Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-28

    ... Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources AGENCY... direct final rule titled ``Quality Assurance Requirements for Continuous Opacity Monitoring Systems at...--Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources Docket, EPA...

  7. The OA System of College - - Design of the Teaching Quality Monitoring Subsystem

    NASA Astrophysics Data System (ADS)

    Wu, Hongjuan; Ying, Hong; Jiang, Youyi; Yan, Pei

    According to the drawbacks of traditional teaching quality monitoring subsystems and based on the achievements of practical research in the teaching quality monitoring administration in College, this paper provides a design of overall structure of teaching quality monitoring subsystem, that is more suitable for colleges' management. This new system is endowed with the same features as .NET application programes: easy to extend, easy to maintain, flexible, convenient, and it let enterprises, students' parents and excellent graduates participate in teaching quality monitoring administration, have significant effect to ensure the quality of talent training in colleges.

  8. WATER QUALITY EARLY WARNING SYSTEMS FOR SOURCE WATER AND DISTRIBUTION SYSTEM MONITORING

    EPA Science Inventory

    A variety of probes for use in continuous monitoring of water quality exist. They range from single parameter chemical/physical probes to comprehensive screening systems based on whole organism responses. Originally developed for monitoring specific characteristics of water qua...

  9. Space Station Environmental Health System water quality monitoring

    NASA Technical Reports Server (NTRS)

    Vincze, Johanna E.; Sauer, Richard L.

    1990-01-01

    One of the unique aspects of the Space Station is that it will be a totally encapsulated environment and the air and water supplies will be reclaimed for reuse. The Environmental Health System, a subsystem of CHeCS (Crew Health Care System), must monitor the air and water on board the Space Station Freedom to verify that the quality is adequate for crew safety. Specifically, the Water Quality Subsystem will analyze the potable and hygiene water supplies regularly for organic, inorganic, particulate, and microbial contamination. The equipment selected to perform these analyses will be commercially available instruments which will be converted for use on board the Space Station Freedom. Therefore, the commercial hardware will be analyzed to identify the gravity dependent functions and modified to eliminate them. The selection, analysis, and conversion of the off-the-shelf equipment for monitoring the Space Station reclaimed water creates a challenging project for the Water Quality engineers and scientists.

  10. Wastewater quality monitoring system using sensor fusion and machine learning techniques.

    PubMed

    Qin, Xusong; Gao, Furong; Chen, Guohua

    2012-03-15

    A multi-sensor water quality monitoring system incorporating an UV/Vis spectrometer and a turbidimeter was used to monitor the Chemical Oxygen Demand (COD), Total Suspended Solids (TSS) and Oil & Grease (O&G) concentrations of the effluents from the Chinese restaurant on campus and an electrocoagulation-electroflotation (EC-EF) pilot plant. In order to handle the noise and information unbalance in the fused UV/Vis spectra and turbidity measurements during the calibration model building, an improved boosting method, Boosting-Iterative Predictor Weighting-Partial Least Squares (Boosting-IPW-PLS), was developed in the present study. The Boosting-IPW-PLS method incorporates IPW into boosting scheme to suppress the quality-irrelevant variables by assigning small weights, and builds up the models for the wastewater quality predictions based on the weighted variables. The monitoring system was tested in the field with satisfactory results, underlying the potential of this technique for the online monitoring of water quality. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. Development and evaluation of a helicopter-borne water-quality monitoring system

    NASA Technical Reports Server (NTRS)

    Wallace, J. W.; Jordan, R. A.; Flynn, J.; Thomas, R. W.

    1978-01-01

    A small, helicopter-borne water-quality monitoring package is being developed by the NASA/EPA using a combination of basic in situ water quality sensors and physical sample collector technology. The package is a lightweight system which can be carried and operated by one person as a passenger in a small helicopter typically available by rental at commercial airports. Real-time measurements are made by suspending the water quality monitoring package with a cable from the hovering helicopter. Designed primarily for use in rapidly assessing hazardous material spills in inland and coastal zone water bodies, the system can survey as many as 20 data stations up to 1.5 kilometers apart in 1 hour. The system provides several channels of sensor data and allows for the addition of future sensors. The system will also collect samples from selected sites with sample collection on command. An EPA Spill Response Team member can easily transport, deploy, and operate the water quality monitoring package to determine the distribution, movement, and concentration of the spilled material in the water body.

  12. Procedure 5 Quality Assurance Requirements For Vapor Phase Mercury Continuous Emissions Monitoring Systems And Sorbent Trap Monitoring Systems Used For Compliance Determination At Stationary Sources

    EPA Pesticide Factsheets

    Promulgated quality assurance Procedure 5 Quality Assurance Requirements For Vapor Phase Mercury Continuous Emissions Monitoring Systems And Sorbent Trap Monitoring Systems Used For Compliance Determination At Stationary Sources

  13. Study of weld quality real-time monitoring system for auto-body assembly

    NASA Astrophysics Data System (ADS)

    Xu, Jun; Li, Yong-Bing; Chen, Guan-Long

    2005-12-01

    Resistance spot welding (RSW) is widely used for the auto-body assembly in automotive industry. But RSW suffers from a major problem of inconsistent quality from weld to weld. The major problem is the complexity of the basic process that may involve material coatings, electrode force, electrode wear, fit up, etc. Therefore weld quality assurance is still a big challenge and goal. Electrode displacement has proved to be a particularly useful signal which correlates well with weld quality. This paper introduces a novel auto-body spot weld quality monitoring system which uses electrode displacement as the quality parameter. This system chooses the latest laser displacement sensor with high resolution to measure the real-time electrode displacement. It solves the interference problem of sensor mounting by designing special fixture, and can be successfully applied on the portable welding machine. It is capable of evaluating weld quality and making diagnosis of process variations such as surface asperities, shunting, worn electrode and weld expansion with real-time electrode displacement. As proved by application in the workshop, the monitoring system has good stability and reliability, and is qualified for monitoring weld quality in process.

  14. The ALICE data quality monitoring system

    NASA Astrophysics Data System (ADS)

    von Haller, B.; Telesca, A.; Chapeland, S.; Carena, F.; Carena, W.; Chibante Barroso, V.; Costa, F.; Denes, E.; Divià, R.; Fuchs, U.; Simonetti, G.; Soós, C.; Vande Vyvre, P.; ALICE Collaboration

    2011-12-01

    ALICE (A Large Ion Collider Experiment) is the heavy-ion detector designed to study the physics of strongly interacting matter and the quark-gluon plasma at the CERN Large Hadron Collider (LHC). The online Data Quality Monitoring (DQM) is a key element of the Data Acquisition's software chain. It provide shifters with precise and complete information to quickly identify and overcome problems, and as a consequence to ensure acquisition of high quality data. DQM typically involves the online gathering, the analysis by user-defined algorithms and the visualization of monitored data. This paper describes the final design of ALICE'S DQM framework called AMORE (Automatic MOnitoRing Environment), as well as its latest and coming features like the integration with the offline analysis and reconstruction framework, a better use of multi-core processors by a parallelization effort, and its interface with the eLogBook. The concurrent collection and analysis of data in an online environment requires the framework to be highly efficient, robust and scalable. We will describe what has been implemented to achieve these goals and the procedures we follow to ensure appropriate robustness and performance. We finally review the wide range of usages people make of this framework, from the basic monitoring of a single sub-detector to the most complex ones within the High Level Trigger farm or using the Prompt Reconstruction and we describe the various ways of accessing the monitoring results. We conclude with our experience, before and after the LHC startup, when monitoring the data quality in a challenging environment.

  15. DESIGN, DEVELOPMENT, AND FIELD DEMONSTRATION OF A REMOTELY DEPLOYABLE WATER QUALITY MONITORING SYSTEM

    EPA Science Inventory

    A prototype water quality monitoring system is described which offers almost continuous in situ monitoring. The two-man portable system features: (1) a microprocessor controlled central processing unit which allows preprogrammed sampling schedules and reprogramming in situ; (2) a...

  16. Experiences and recommendations in deploying a real-time, water quality monitoring system

    NASA Astrophysics Data System (ADS)

    O'Flynn, B.; Regan, F.; Lawlor, A.; Wallace, J.; Torres, J.; O'Mathuna, C.

    2010-12-01

    Monitoring of water quality at a river basin level to meet the requirements of the Water Framework Directive (WFD) using conventional sampling and laboratory-based techniques poses a significant financial burden. Wireless sensing systems offer the potential to reduce these costs considerably, as well as provide more useful, continuous monitoring capabilities by giving an accurate idea of the changing environmental and water quality in real time. It is unlikely that the traditional spot/grab sampling will provide a reasonable estimate of the true maximum and/or mean concentration for a particular physicochemical variable in a water body with marked temporal variability. When persistent fluctuations occur, it is likely only to be detected through continuous measurements, which have the capability of detecting sporadic peaks of concentration. Thus, in situ sensors capable of continuous sampling of parameters required under the WFD would therefore provide more up-to-date information, cut monitoring costs and provide better coverage representing long-term trends in fluctuations of pollutant concentrations. DEPLOY is a technology demonstration project, which began planning and station selection and design in August 2008 aiming to show how state-of-the-art technology could be implemented for cost-effective, continuous and real-time monitoring of a river catchment. The DEPLOY project is seen as an important building block in the realization of a wide area autonomous network of sensors capable of monitoring the spatial and temporal distribution of important water quality and environmental target parameters. The demonstration sites chosen are based in the River Lee, which flows through Ireland's second largest city, Cork, and were designed to include monitoring stations in five zones considered typical of significant river systems--these monitor water quality parameters such as pH, temperature, depth, conductivity, turbidity and dissolved oxygen. Over one million data points

  17. A reliable sewage quality abnormal event monitoring system.

    PubMed

    Li, Tianling; Winnel, Melissa; Lin, Hao; Panther, Jared; Liu, Chang; O'Halloran, Roger; Wang, Kewen; An, Taicheng; Wong, Po Keung; Zhang, Shanqing; Zhao, Huijun

    2017-09-15

    With closing water loop through purified recycled water, wastewater becomes a part of source water, requiring reliable wastewater quality monitoring system (WQMS) to manage wastewater source and mitigate potential health risks. However, the development of reliable WQMS is fatally constrained by severe contamination and biofouling of sensors due to the hostile analytical environment of wastewaters, especially raw sewages, that challenges the limit of existing sensing technologies. In this work, we report a technological solution to enable the development of WQMS for real-time abnormal event detection with high reliability and practicality. A vectored high flow hydrodynamic self-cleaning approach and a dual-sensor self-diagnostic concept are adopted for WQMS to effectively encounter vital sensor failing issues caused by contamination and biofouling and ensure the integrity of sensing data. The performance of the WQMS has been evaluated over a 3-year trial period at different sewage catchment sites across three Australian states. It has demonstrated that the developed WQMS is capable of continuously operating in raw sewage for a prolonged period up to 24 months without maintenance and failure, signifying the high reliability and practicality. The demonstrated WQMS capability to reliably acquire real-time wastewater quality information leaps forward the development of effective wastewater source management system. The reported self-cleaning and self-diagnostic concepts should be applicable to other online water quality monitoring systems, opening a new way to encounter the common reliability and stability issues caused by sensor contamination and biofouling. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. The role of Environmental Health System air quality monitors in Space Station Contingency Operations

    NASA Technical Reports Server (NTRS)

    Limero, Thomas F.; Wilson, Steve; Perlot, Susan; James, John

    1992-01-01

    This paper describes the Space Station Freedom (SSF) Environmental Health System's air-quality monitoring strategy and instrumentation. A two-tier system has been developed, consisting of first-alert instruments that warn the crew of airborne contamination and a volatile organic analyzer that can identify volatile organic contaminants in near-real time. The strategy for air quality monitoring on SSF is designed to provide early detection so that the contamination can be confined to one module and so that crew health and safety can be protected throughout the contingency event. The use of air-quality monitors in fixed and portable modes will be presented as a means of following the progress of decontamination efforts and ensuring acceptable air quality in a module after an incident. The technology of each instrument will be reviewed briefly; the main focus of this paper, however, will be the use of air-quality monitors before, during, and after contingency incidents.

  19. Automated monitoring of recovered water quality

    NASA Technical Reports Server (NTRS)

    Misselhorn, J. E.; Hartung, W. H.; Witz, S. W.

    1974-01-01

    Laboratory prototype water quality monitoring system provides automatic system for online monitoring of chemical, physical, and bacteriological properties of recovered water and for signaling malfunction in water recovery system. Monitor incorporates whenever possible commercially available sensors suitably modified.

  20. Systems for monitoring and digitally recording water-quality parameters

    USGS Publications Warehouse

    Smoot, George F.; Blakey, James F.

    1966-01-01

    Digital recording of water-quality parameters is a link in the automated data collection and processing system of the U.S. Geological Survey. The monitoring and digital recording systems adopted by the Geological Survey, while punching all measurements on a standard paper tape, provide a choice of compatible components to construct a system to meet specific physical problems and data needs. As many as 10 parameters can be recorded by an Instrument, with the only limiting criterion being that measurements are expressed as electrical signals.

  1. A design of wireless sensor networks for a power quality monitoring system.

    PubMed

    Lim, Yujin; Kim, Hak-Man; Kang, Sanggil

    2010-01-01

    Power grids deal with the business of generation, transmission, and distribution of electric power. Recently, interest in power quality in electrical distribution systems has increased rapidly. In Korea, the communication network to deliver voltage, current, and temperature measurements gathered from pole transformers to remote monitoring centers employs cellular mobile technology. Due to high cost of the cellular mobile technology, power quality monitoring measurements are limited and data gathering intervals are large. This causes difficulties in providing the power quality monitoring service. To alleviate the problems, in this paper we present a communication infrastructure to provide low cost, reliable data delivery. The communication infrastructure consists of wired connections between substations and monitoring centers, and wireless connections between pole transformers and substations. For the wireless connection, we employ a wireless sensor network and design its corresponding data forwarding protocol to improve the quality of data delivery. For the design, we adopt a tree-based data forwarding protocol in order to customize the distribution pattern of the power quality information. We verify the performance of the proposed data forwarding protocol quantitatively using the NS-2 network simulator.

  2. Strategies for monitoring the bacteriological quality of water supply in distribution systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Geldreich, E.E.; Goodrich, J.A.; Clark, R.M.

    1989-01-01

    Monitoring strategies for characterizing the bacteriological quality of water in the distribution system require a complete understanding of a variety of interrelated aspects that include treated water quality, water-supply retention in storage and infrastructure deterioration in the distribution system. A study of field data from several water-supply utilities was used to highlight some innovative interpretations of compliance monitoring data. Major perceptions include: The use of a 5% coliform frequency of occurrence limit highlights compliance significance in those situations where there are clusters of positive samples containing less than 4 coliforms per 100 mL. Unfortunately, this presence/absence concept does not providemore » any indication of the magnitude of a contamination event.« less

  3. Construction and application of an intelligent air quality monitoring system for healthcare environment.

    PubMed

    Yang, Chao-Tung; Liao, Chi-Jui; Liu, Jung-Chun; Den, Walter; Chou, Ying-Chyi; Tsai, Jaw-Ji

    2014-02-01

    Indoor air quality monitoring in healthcare environment has become a critical part of hospital management and policy. Manual air sampling and analysis are cost-inhibitive and do not provide real-time air quality data and response measures. In this month-long study over 14 sampling locations in a public hospital in Taiwan, we observed a positive correlation between CO(2) concentration and population, total bacteria, and particulate matter concentrations, thus monitoring CO(2) concentration as a general indicator for air quality could be a viable option. Consequently, an intelligent environmental monitoring system consisting of a CO(2)/temperature/humidity sensor, a digital plug, and a ZigBee Router and Coordinator was developed and tested. The system also included a backend server that received and analyzed data, as well as activating ventilation and air purifiers when CO(2) concentration exceeded a pre-set value. Alert messages can also be delivered to offsite users through mobile devices.

  4. A Prototype Educational Delivery System Using Water Quality Monitoring as a Model.

    ERIC Educational Resources Information Center

    Glazer, Richard B.

    This report describes the model educational delivery system used by Ulster County Community College in its water quality monitoring program. The educational delivery system described in the report encompasses the use of behavioral objectives as its foundation and builds upon this foundation to form a complete system whose outcomes can be measured,…

  5. Monitoring system for the quality assessment in additive manufacturing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carl, Volker, E-mail: carl@t-zfp.de

    Additive Manufacturing (AM) refers to a process by which a set of digital data -representing a certain complex 3dim design - is used to grow the respective 3dim real structure equal to the corresponding design. For the powder-based EOS manufacturing process a variety of plastic and metal materials can be used. Thereby, AM is in many aspects a very powerful tool as it can help to overcome particular limitations in conventional manufacturing. AM enables more freedom of design, complex, hollow and/or lightweight structures as well as product individualisation and functional integration. As such it is a promising approach with respectmore » to the future design and manufacturing of complex 3dim structures. On the other hand, it certainly calls for new methods and standards in view of quality assessment. In particular, when utilizing AM for the design of complex parts used in aviation and aerospace technologies, appropriate monitoring systems are mandatory. In this respect, recently, sustainable progress has been accomplished by joining the common efforts and concerns of a manufacturer Additive Manufacturing systems and respective materials (EOS), along with those of an operator of such systems (MTU Aero Engines) and experienced application engineers (Carl Metrology), using decent know how in the field of optical and infrared methods regarding non-destructive-examination (NDE). The newly developed technology is best described by a high-resolution layer by layer inspection technique, which allows for a 3D tomography-analysis of the complex part at any time during the manufacturing process. Thereby, inspection costs are kept rather low by using smart image-processing methods as well as CMOS sensors instead of infrared detectors. Moreover, results from conventional physical metallurgy may easily be correlated with the predictive results of the monitoring system which not only allows for improvements of the AM monitoring system, but finally leads to an optimisation of the

  6. Monitoring system for the quality assessment in additive manufacturing

    NASA Astrophysics Data System (ADS)

    Carl, Volker

    2015-03-01

    Additive Manufacturing (AM) refers to a process by which a set of digital data -representing a certain complex 3dim design - is used to grow the respective 3dim real structure equal to the corresponding design. For the powder-based EOS manufacturing process a variety of plastic and metal materials can be used. Thereby, AM is in many aspects a very powerful tool as it can help to overcome particular limitations in conventional manufacturing. AM enables more freedom of design, complex, hollow and/or lightweight structures as well as product individualisation and functional integration. As such it is a promising approach with respect to the future design and manufacturing of complex 3dim structures. On the other hand, it certainly calls for new methods and standards in view of quality assessment. In particular, when utilizing AM for the design of complex parts used in aviation and aerospace technologies, appropriate monitoring systems are mandatory. In this respect, recently, sustainable progress has been accomplished by joining the common efforts and concerns of a manufacturer Additive Manufacturing systems and respective materials (EOS), along with those of an operator of such systems (MTU Aero Engines) and experienced application engineers (Carl Metrology), using decent know how in the field of optical and infrared methods regarding non-destructive-examination (NDE). The newly developed technology is best described by a high-resolution layer by layer inspection technique, which allows for a 3D tomography-analysis of the complex part at any time during the manufacturing process. Thereby, inspection costs are kept rather low by using smart image-processing methods as well as CMOS sensors instead of infrared detectors. Moreover, results from conventional physical metallurgy may easily be correlated with the predictive results of the monitoring system which not only allows for improvements of the AM monitoring system, but finally leads to an optimisation of the quality

  7. Method, system and apparatus for monitoring and adjusting the quality of indoor air

    DOEpatents

    Hartenstein, Steven D.; Tremblay, Paul L.; Fryer, Michael O.; Hohorst, Frederick A.

    2004-03-23

    A system, method and apparatus is provided for monitoring and adjusting the quality of indoor air. A sensor array senses an air sample from the indoor air and analyzes the air sample to obtain signatures representative of contaminants in the air sample. When the level or type of contaminant poses a threat or hazard to the occupants, the present invention takes corrective actions which may include introducing additional fresh air. The corrective actions taken are intended to promote overall health of personnel, prevent personnel from being overexposed to hazardous contaminants and minimize the cost of operating the HVAC system. The identification of the contaminants is performed by comparing the signatures provided by the sensor array with a database of known signatures. Upon identification, the system takes corrective actions based on the level of contaminant present. The present invention is capable of learning the identity of previously unknown contaminants, which increases its ability to identify contaminants in the future. Indoor air quality is assured by monitoring the contaminants not only in the indoor air, but also in the outdoor air and the air which is to be recirculated. The present invention is easily adaptable to new and existing HVAC systems. In sum, the present invention is able to monitor and adjust the quality of indoor air in real time by sensing the level and type of contaminants present in indoor air, outdoor and recirculated air, providing an intelligent decision about the quality of the air, and minimizing the cost of operating an HVAC system.

  8. FPGA-based firmware model for extended measurement systems with data quality monitoring

    NASA Astrophysics Data System (ADS)

    Wojenski, A.; Pozniak, K. T.; Mazon, D.; Chernyshova, M.

    2017-08-01

    Modern physics experiments requires construction of advanced, modular measurement systems for data processing and registration purposes. Components are often designed in one of the common mechanical and electrical standards, e.g. VME or uTCA. The paper is focused on measurement systems using FPGAs as data processing blocks, especially for plasma diagnostics using GEM detectors with data quality monitoring aspects. In the article is proposed standardized model of HDL FPGA firmware implementation, for use in a wide range of different measurement system. The effort was made in term of flexible implementation of data quality monitoring along with source data dynamic selection. In the paper is discussed standard measurement system model followed by detailed model of FPGA firmware for modular measurement systems. Considered are both: functional blocks and data buses. In the summary, necessary blocks and signal lines are described. Implementation of firmware following the presented rules should provide modular design, with ease of change different parts of it. The key benefit is construction of universal, modular HDL design, that can be applied in different measurement system with simple adjustments.

  9. [Designing and implementation of a web-based quality monitoring system for plasma glucose measurement in multicenter population study].

    PubMed

    Liu, Yong; Wang, Limin; Pang, Richard; Mo, Nanxun; Hu, Yan; Deng, Qian; Hu, Zhaohui

    2015-05-01

    The aim of this paper is to describe the designing and implementation of a web-based plasma glucose measurement quality monitoring system to assess the analytical quality of plasma glucose measurements in multicenter population study and provide evidence for the future studies. In the chronic non-communicable disease and related factor surveillance in China, a web based quality monitoring system for plasma glucose measurement was established to conduct evaluation on plasma glucose monitoring quality and effectiveness in 302 surveillance centers, including quality control data entry, transmission and feedback. The majority of the surveillance centers met the quality requirements and passed the evaluation of reproducibility and precision of plasma glucose measurement, only a few centers required intensive training and re-assessment. In order to ensure the completeness and reliability of plasma glucose measurement in the surveillance centers, the establishment of web-based plasma glucose measurement quality control system can facilitate the identification of the qualified surveillance centers and evaluation of plasma glucose measurement quality in different regions. Communication and training are important in ensuring plasma glucose measurement quality. It is necessary to further improve this web-based plasma glucose measurement quality monitoring system in the future to reduce the method specific plasma glucose measurement bias.

  10. System of Monitoring the Quality of Higher Education in UK Universities: Experience for Ukraine

    ERIC Educational Resources Information Center

    Krasilnikova, Hanna

    2014-01-01

    The article deals with the experience of the use of the system of internal monitoring of the quality of higher education in UK Universities. There has been analyzed the existing model of the system of higher education monitoring at the level of a higher education institution within the scope of the British higher education model, discovered by a…

  11. WSN based indoor air quality monitoring in classrooms

    NASA Astrophysics Data System (ADS)

    Wang, S. K.; Chew, S. P.; Jusoh, M. T.; Khairunissa, A.; Leong, K. Y.; Azid, A. A.

    2017-03-01

    Indoor air quality monitoring is essential as the human health is directly affected by indoor air quality. This paper presents the investigations of the impact of undergraduate students' concentration during lecture due to the indoor air quality in classroom. Three environmental parameters such as temperature, relative humidity and concentration of carbon dioxide are measured using wireless sensor network based air quality monitoring system. This simple yet reliable system is incorporated with DHT-11 and MG-811 sensors. Two classrooms were selected to install the monitoring system. The level of indoor air quality were measured and students' concentration was assessed using intelligent test during normal lecturing section. The test showed significant correlation between the collected environmental parameters and the students' level of performances in their study.

  12. Assessment of Water-Quality Monitoring and a Proposed Water-Quality Monitoring Network for the Mosquito Lagoon Basin, East-Central Florida

    USGS Publications Warehouse

    Kroening, Sharon E.

    2008-01-01

    Surface- and ground-water quality data from the Mosquito Lagoon Basin were compiled and analyzed to: (1) describe historical and current monitoring in the basin, (2) summarize surface- and ground-water quality conditions with an emphasis on identifying areas that require additional monitoring, and (3) develop a water-quality monitoring network to meet the goals of Canaveral National Seashore (a National Park) and to fill gaps in current monitoring. Water-quality data were compiled from the U.S. Environmental Protection Agency's STORET system, the U.S. Geological Survey's National Water Information System, or from the agency which collected the data. Most water-quality monitoring focused on assessing conditions in Mosquito Lagoon. Significant spatial and/or seasonal variations in water-quality constituents in the lagoon were quantified for pH values, fecal coliform bacteria counts, and concentrations of dissolved oxygen, total nitrogen, total phosphorus, chlorophyll-a, and total suspended solids. Trace element, pesticide, and ground-water-quality data were more limited. Organochlorine insecticides were the major class of pesticides analyzed. A surface- and ground-water-quality monitoring network was designed for the Mosquito Lagoon Basin which emphasizes: (1) analysis of compounds indicative of human activities, including pesticides and other trace organic compounds present in domestic and industrial waste; (2) greater data collection in the southern part of Mosquito Lagoon where spatial variations in water-quality constituents were quantified; and (3) additional ground-water-quality data collection in the surficial aquifer system and Upper Floridan aquifer. Surface-water-quality data collected as part of this network would include a fixed-station monitoring network of eight sites in the southern part of the basin, including a canal draining Oak Hill. Ground-water quality monitoring should be done routinely at about 20 wells in the surficial aquifer system and Upper

  13. Water quality monitoring of Jialing-River in Chongqing using advanced ion chromatographic system.

    PubMed

    Tanaka, Kazuhiko; Shi, Chao-Hong; Nakagoshi, Nobukazu

    2012-04-01

    The water quality monitoring operation to evaluate the water quality of polluted river is an extremely important task for the river-watershed management/control based on the environmental policy. In this study, the novel, simple and convenient water quality monitoring of Jialing-River in Chongqing, China was carried out using an advanced ion chromatography (IC) consisting of ion-exclusion/cation-exchange chromatography (IEC/CEC) with conductivity detection for determining simultaneously the common anions such as SO4(2-), Cl(-), and NO3(-) and the cations such as Na+, NH4+, K+, Mg2+, and Ca2+, the ion-exclusion chromatography (IEC) with visible detection for determining simultaneously the nutrient components such as phosphate and silicate ions, and the IEC with the enhanced conductivity detection using a post column of K+-form cation-exchange resin for determining HCO3(-)-alkalinity as an inorganic-carbon source for biomass synthesis in biological reaction process under the aerobic conditions. According to the ionic balance theory between the total equivalent concentrations of anions and cations, the water quality evaluation of the Jialing-River waters taking at different sampling sites in Chongqing metropolitan area was carried out using the advanced IC system. As a result, the effectiveness of this novel water quality monitoring methodology using the IC system was demonstrated on the several practical applications to a typical biological sewage treatment plant on Jialing-River of Chongqing.

  14. A new air quality monitoring and early warning system: Air quality assessment and air pollutant concentration prediction.

    PubMed

    Yang, Zhongshan; Wang, Jian

    2017-10-01

    Air pollution in many countries is worsening with industrialization and urbanization, resulting in climate change and affecting people's health, thus, making the work of policymakers more difficult. It is therefore both urgent and necessary to establish amore scientific air quality monitoring and early warning system to evaluate the degree of air pollution objectively, and predict pollutant concentrations accurately. However, the integration of air quality assessment and air pollutant concentration prediction to establish an air quality system is not common. In this paper, we propose a new air quality monitoring and early warning system, including an assessment module and forecasting module. In the air quality assessment module, fuzzy comprehensive evaluation is used to determine the main pollutants and evaluate the degree of air pollution more scientifically. In the air pollutant concentration prediction module, a novel hybridization model combining complementary ensemble empirical mode decomposition, a modified cuckoo search and differential evolution algorithm, and an Elman neural network, is proposed to improve the forecasting accuracy of six main air pollutant concentrations. To verify the effectiveness of this system, pollutant data for two cities in China are used. The result of the fuzzy comprehensive evaluation shows that the major air pollutants in Xi'an and Jinan are PM 10 and PM 2.5 respectively, and that the air quality of Xi'an is better than that of Jinan. The forecasting results indicate that the proposed hybrid model is remarkably superior to all benchmark models on account of its higher prediction accuracy and stability. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Development of a laboratory prototype water quality monitoring system suitable for use in zero gravity

    NASA Technical Reports Server (NTRS)

    Misselhorn, J. E.; Witz, S.; Hartung, W. H.

    1973-01-01

    The development of a laboratory prototype water quality monitoring system for use in the evaluation of candidate water recovery systems and for study of techniques for measuring potability parameters is reported. Sensing techniques for monitoring of the most desirable parameters are reviewed in terms of their sensitivities and complexities, and their recommendations for sensing techniques are presented. Rationale for selection of those parameters to be monitored (pH, specific conductivity, Cr(+6), I2, total carbon, and bacteria) in a next generation water monitor is presented along with an estimate of flight system specifications. A master water monitor development schedule is included.

  16. Progress and lessons learned from water-quality monitoring networks

    USGS Publications Warehouse

    Myers, Donna N.; Ludtke, Amy S.

    2017-01-01

    Stream-quality monitoring networks in the United States were initiated and expanded after passage of successive federal water-pollution control laws from 1948 to 1972. The first networks addressed information gaps on the extent and severity of stream pollution and served as early warning systems for spills. From 1965 to 1972, monitoring networks expanded to evaluate compliance with stream standards, track emerging issues, and assess water-quality status and trends. After 1972, concerns arose regarding the ability of monitoring networks to determine if water quality was getting better or worse and why. As a result, monitoring networks adopted a hydrologic systems approach targeted to key water-quality issues, accounted for human and natural factors affecting water quality, innovated new statistical methods, and introduced geographic information systems and models that predict water quality at unmeasured locations. Despite improvements, national-scale monitoring networks have declined over time. Only about 1%, or 217, of more than 36,000 US Geological Survey monitoring sites sampled from 1975 to 2014 have been operated throughout the four decades since passage of the 1972 Clean Water Act. Efforts to sustain monitoring networks are important because these networks have collected information crucial to the description of water-quality trends over time and are providing information against which to evaluate future trends.

  17. A ground-water-quality monitoring program for Nevada

    USGS Publications Warehouse

    Nowlin, Jon O.

    1986-01-01

    A program was designed for the systematic monitoring of ground-water quality in Nevada. Basic hydrologic and water-quality principles are discussed in the formulation of a rational approach to developing a statewide monitoring program. A review of ground-water monitoring efforts in Nevada through 1977 indicates that few requirements for an effective statewide program are being met. A suggested program has been developed that consists of five major elements: (1) A Background-Quality Network to assess the existing water quality in Nevada aquifers, (2) a Contamination Source Inventory of known or potential threats to ground-water quality, (3) Surveillance Networks to monitor ground-water quality in selected hydrographic areas, (4) Intensive Surveys of individual instances of known or potential ground-water contamination, and (5) Ground-Water Data File to manage data generated by the other monitoring elements. Two indices have been developed to help assign rational priorities for monitoring ground water in the 255 hydrographic areas of Nevada: (1) A Hydrographic-Area Priority Index for surveillance monitoring, and (2) A Development-Potential Index for background monitoring of areas with little or no current development. Requirements for efficient management of data from ground-water monitoring are discussed and the three major systems containing Nevada ground-water data are reviewed. More than 11,000 chemical analyses of ground water have been acquired from existing systems and incorporated into a prototype data base.

  18. A reliable low cost integrated wireless sensor network for water quality monitoring and level control system in UAE

    NASA Astrophysics Data System (ADS)

    Abou-Elnour, Ali; Khaleeq, Hyder; Abou-Elnour, Ahmad

    2016-04-01

    In the present work, wireless sensor network and real-time controlling and monitoring system are integrated for efficient water quality monitoring for environmental and domestic applications. The proposed system has three main components (i) the sensor circuits, (ii) the wireless communication system, and (iii) the monitoring and controlling unit. LabView software has been used in the implementation of the monitoring and controlling system. On the other hand, ZigBee and myRIO wireless modules have been used to implement the wireless system. The water quality parameters are accurately measured by the present computer based monitoring system and the measurement results are instantaneously transmitted and published with minimum infrastructure costs and maximum flexibility in term of distance or location. The mobility and durability of the proposed system are further enhanced by fully powering via a photovoltaic system. The reliability and effectiveness of the system are evaluated under realistic operating conditions.

  19. Optimizing the Energy and Throughput of a Water-Quality Monitoring System.

    PubMed

    Olatinwo, Segun O; Joubert, Trudi-H

    2018-04-13

    This work presents a new approach to the maximization of energy and throughput in a wireless sensor network (WSN), with the intention of applying the approach to water-quality monitoring. Water-quality monitoring using WSN technology has become an interesting research area. Energy scarcity is a critical issue that plagues the widespread deployment of WSN systems. Different power supplies, harvesting energy from sustainable sources, have been explored. However, when energy-efficient models are not put in place, energy harvesting based WSN systems may experience an unstable energy supply, resulting in an interruption in communication, and low system throughput. To alleviate these problems, this paper presents the joint maximization of the energy harvested by sensor nodes and their information-transmission rate using a sum-throughput technique. A wireless information and power transfer (WIPT) method is considered by harvesting energy from dedicated radio frequency sources. Due to the doubly near-far condition that confronts WIPT systems, a new WIPT system is proposed to improve the fairness of resource utilization in the network. Numerical simulation results are presented to validate the mathematical formulations for the optimization problem, which maximize the energy harvested and the overall throughput rate. Defining the performance metrics of achievable throughput and fairness in resource sharing, the proposed WIPT system outperforms an existing state-of-the-art WIPT system, with the comparison based on numerical simulations of both systems. The improved energy efficiency of the proposed WIPT system contributes to addressing the problem of energy scarcity.

  20. LHCb data quality monitoring

    NASA Astrophysics Data System (ADS)

    Adinolfi, M.; Archilli, F.; Baldini, W.; Baranov, A.; Derkach, D.; Panin, A.; Pearce, A.; Ustyuzhanin, A.

    2017-10-01

    Data quality monitoring, DQM, is crucial in a high-energy physics experiment to ensure the correct functioning of the experimental apparatus during the data taking. DQM at LHCb is carried out in two phases. The first one is performed on-site, in real time, using unprocessed data directly from the LHCb detector, while the second, also performed on-site, requires the reconstruction of the data selected by the LHCb trigger system and occurs later. For the LHC Run II data taking the LHCb collaboration has re-engineered the DQM protocols and the DQM graphical interface, moving the latter to a web-based monitoring system, called Monet, thus allowing researchers to perform the second phase off-site. In order to support the operator’s task, Monet is also equipped with an automated, fully configurable alarm system, thus allowing its use not only for DQM purposes, but also to track and assess the quality of LHCb software and simulation over time.

  1. Design, development, and field demonstration of a remotely deployable water quality monitoring system

    NASA Technical Reports Server (NTRS)

    Wallace, J. W.; Lovelady, R. W.; Ferguson, R. L.

    1981-01-01

    A prototype water quality monitoring system is described which offers almost continuous in situ monitoring. The two-man portable system features: (1) a microprocessor controlled central processing unit which allows preprogrammed sampling schedules and reprogramming in situ; (2) a subsurface unit for multiple depth capability and security from vandalism; (3) an acoustic data link for communications between the subsurface unit and the surface control unit; (4) eight water quality parameter sensors; (5) a nonvolatile magnetic bubble memory which prevents data loss in the event of power interruption; (6) a rechargeable power supply sufficient for 2 weeks of unattended operation; (7) a water sampler which can collect samples for laboratory analysis; (8) data output in direct engineering units on printed tape or through a computer compatible link; (9) internal electronic calibration eliminating external sensor adjustment; and (10) acoustic location and recovery systems. Data obtained in Saginaw Bay, Lake Huron are tabulated.

  2. Air Quality Monitor

    NASA Technical Reports Server (NTRS)

    1996-01-01

    The Stak-Tracker CEM (Continuous Emission Monitor) Gas Analyzer is an air quality monitor capable of separating the various gases in a bulk exhaust stream and determining the amounts of individual gases present within the stream. The monitor is produced by GE Reuter- Stokes, a subsidiary of GE Corporate Research & Development Center. The Stak-Tracker uses a Langley Research Center software package which measures the concentration of a target gas by determining the degree to which molecules of that gas absorb an infrared beam. The system is environmental-friendly, fast and has relatively low installation and maintenance costs. It is applicable to gas turbines and various industries including glass, paper and cement.

  3. An Architecture for Continuous Data Quality Monitoring in Medical Centers.

    PubMed

    Endler, Gregor; Schwab, Peter K; Wahl, Andreas M; Tenschert, Johannes; Lenz, Richard

    2015-01-01

    In the medical domain, data quality is very important. Since requirements and data change frequently, continuous and sustainable monitoring and improvement of data quality is necessary. Working together with managers of medical centers, we developed an architecture for a data quality monitoring system. The architecture enables domain experts to adapt the system during runtime to match their specifications using a built-in rule system. It also allows arbitrarily complex analyses to be integrated into the monitoring cycle. We evaluate our architecture by matching its components to the well-known data quality methodology TDQM.

  4. Monitoring Indoor Air Quality for Enhanced Occupational Health.

    PubMed

    Pitarma, Rui; Marques, Gonçalo; Ferreira, Bárbara Roque

    2017-02-01

    Indoor environments are characterized by several pollutant sources. Because people spend more than 90% of their time in indoor environments, several studies have pointed out the impact of indoor air quality on the etiopathogenesis of a wide number of non-specific symptoms which characterizes the "Sick Building Syndrome", involving the skin, the upper and lower respiratory tract, the eyes and the nervous system, as well as many building related diseases. Thus, indoor air quality (IAQ) is recognized as an important factor to be controlled for the occupants' health and comfort. The majority of the monitoring systems presently available is very expensive and only allow to collect random samples. This work describes the system (iAQ), a low-cost indoor air quality monitoring wireless sensor network system, developed using Arduino, XBee modules and micro sensors, for storage and availability of monitoring data on a web portal in real time. Five micro sensors of environmental parameters (air temperature, humidity, carbon monoxide, carbon dioxide and luminosity) were used. Other sensors can be added for monitoring specific pollutants. The results reveal that the system can provide an effective indoor air quality assessment to prevent exposure risk. In fact, the indoor air quality may be extremely different compared to what is expected for a quality living environment. Systems like this would have benefit as public health interventions to reduce the burden of symptoms and diseases related to "sick buildings".

  5. An Intelligent System for Monitoring the Microgravity Environment Quality On-Board the International Space Station

    NASA Technical Reports Server (NTRS)

    Lin, Paul P.; Jules, Kenol

    2002-01-01

    An intelligent system for monitoring the microgravity environment quality on-board the International Space Station is presented. The monitoring system uses a new approach combining Kohonen's self-organizing feature map, learning vector quantization, and back propagation neural network to recognize and classify the known and unknown patterns. Finally, fuzzy logic is used to assess the level of confidence associated with each vibrating source activation detected by the system.

  6. Optimizing the Energy and Throughput of a Water-Quality Monitoring System

    PubMed Central

    Olatinwo, Segun O.

    2018-01-01

    This work presents a new approach to the maximization of energy and throughput in a wireless sensor network (WSN), with the intention of applying the approach to water-quality monitoring. Water-quality monitoring using WSN technology has become an interesting research area. Energy scarcity is a critical issue that plagues the widespread deployment of WSN systems. Different power supplies, harvesting energy from sustainable sources, have been explored. However, when energy-efficient models are not put in place, energy harvesting based WSN systems may experience an unstable energy supply, resulting in an interruption in communication, and low system throughput. To alleviate these problems, this paper presents the joint maximization of the energy harvested by sensor nodes and their information-transmission rate using a sum-throughput technique. A wireless information and power transfer (WIPT) method is considered by harvesting energy from dedicated radio frequency sources. Due to the doubly near–far condition that confronts WIPT systems, a new WIPT system is proposed to improve the fairness of resource utilization in the network. Numerical simulation results are presented to validate the mathematical formulations for the optimization problem, which maximize the energy harvested and the overall throughput rate. Defining the performance metrics of achievable throughput and fairness in resource sharing, the proposed WIPT system outperforms an existing state-of-the-art WIPT system, with the comparison based on numerical simulations of both systems. The improved energy efficiency of the proposed WIPT system contributes to addressing the problem of energy scarcity. PMID:29652866

  7. Web Information Systems for Monitoring and Control of Indoor Air Quality at Subway Stations

    NASA Astrophysics Data System (ADS)

    Choi, Gi Heung; Choi, Gi Sang; Jang, Joo Hyoung

    In crowded subway stations indoor air quality (IAQ) is a key factor for ensuring the safety, health and comfort of passengers. In this study, a framework for web-based information system in VDN environment for monitoring and control of IAQ in subway stations is suggested. Since physical variables that describing IAQ need to be closely monitored and controlled in multiple locations in subway stations, concept of distributed monitoring and control network using wireless media needs to be implemented. Connecting remote wireless sensor network and device (LonWorks) networks to the IP network based on the concept of VDN can provide a powerful, integrated, distributed monitoring and control performance, making a web-based information system possible.

  8. Accuracy and reliability of Chile's National Air Quality Information System for measuring particulate matter: Beta attenuation monitoring issue.

    PubMed

    Toro A, Richard; Campos, Claudia; Molina, Carolina; Morales S, Raul G E; Leiva-Guzmán, Manuel A

    2015-09-01

    A critical analysis of Chile's National Air Quality Information System (NAQIS) is presented, focusing on particulate matter (PM) measurement. This paper examines the complexity, availability and reliability of monitoring station information, the implementation of control systems, the quality assurance protocols of the monitoring station data and the reliability of the measurement systems in areas highly polluted by particulate matter. From information available on the NAQIS website, it is possible to confirm that the PM2.5 (PM10) data available on the site correspond to 30.8% (69.2%) of the total information available from the monitoring stations. There is a lack of information regarding the measurement systems used to quantify air pollutants, most of the available data registers contain gaps, almost all of the information is categorized as "preliminary information" and neither standard operating procedures (operational and validation) nor assurance audits or quality control of the measurements are reported. In contrast, events that cause saturation of the monitoring detectors located in northern and southern Chile have been observed using beta attenuation monitoring. In these cases, it can only be concluded that the PM content is equal to or greater than the saturation concentration registered by the monitors and that the air quality indexes obtained from these measurements are underestimated. This occurrence has been observed in 12 (20) public and private stations where PM2.5 (PM10) is measured. The shortcomings of the NAQIS data have important repercussions for the conclusions obtained from the data and for how the data are used. However, these issues represent opportunities for improving the system to widen its use, incorporate comparison protocols between equipment, install new stations and standardize the control system and quality assurance. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Telemetric system for hydrology and water quality monitoring in watersheds of northern New Mexico, USA.

    PubMed

    Meyer, Michael L; Huey, Greg M

    2006-05-01

    This study utilized telemetric systems to sample microbes and pathogens in forest, burned forest, rangeland, and urban watersheds to assess surface water quality in northern New Mexico. Four sites included remote mountainous watersheds, prairie rangelands, and a small urban area. The telemetric system was linked to dataloggers with automated event monitoring equipment to monitor discharge, turbidity, electrical conductivity, water temperature, and rainfall during base flow and storm events. Site data stored in dataloggers was uploaded to one of three types of telemetry: 1) radio in rangeland and urban settings; 2) a conventional phone/modem system with a modem positioned at the urban/forest interface; and 3) a satellite system used in a remote mountainous burned forest watershed. The major variables affecting selection of each system were site access, distance, technology, and cost. The systems were compared based on operation and cost. Utilization of telecommunications systems in this varied geographic area facilitated the gathering of hydrologic and water quality data on a timely basis.

  10. Water quality real-time monitoring system via biological detection based on video analysis

    NASA Astrophysics Data System (ADS)

    Xin, Chen; Fei, Yuan

    2017-11-01

    With the development of society, water pollution has become the most serious problem in China. Therefore, real-time water quality monitoring is an important part of human activities and water pollution prevention. In this paper, the behavior of zebrafish was monitored by computer vision. Firstly, the moving target was extracted by the method of saliency detection, and tracked by fitting the ellipse model. Then the motion parameters were extracted by optical flow method, and the data were monitored in real time by means of Hinkley warning and threshold warning. We achieved classification warning through a number of dimensions by comprehensive toxicity index. The experimental results show that the system can achieve more accurate real-time monitoring.

  11. Model-based monitoring of stormwater runoff quality.

    PubMed

    Birch, Heidi; Vezzaro, Luca; Mikkelsen, Peter Steen

    2013-01-01

    Monitoring of micropollutants (MP) in stormwater is essential to evaluate the impacts of stormwater on the receiving aquatic environment. The aim of this study was to investigate how different strategies for monitoring of stormwater quality (combining a model with field sampling) affect the information obtained about MP discharged from the monitored system. A dynamic stormwater quality model was calibrated using MP data collected by automatic volume-proportional sampling and passive sampling in a storm drainage system on the outskirts of Copenhagen (Denmark) and a 10-year rain series was used to find annual average (AA) and maximum event mean concentrations. Use of this model reduced the uncertainty of predicted AA concentrations compared to a simple stochastic method based solely on data. The predicted AA concentration, obtained by using passive sampler measurements (1 month installation) for calibration of the model, resulted in the same predicted level but with narrower model prediction bounds than by using volume-proportional samples for calibration. This shows that passive sampling allows for a better exploitation of the resources allocated for stormwater quality monitoring.

  12. Improving and monitoring air quality.

    PubMed

    DuPont, André

    2018-05-01

    Since the authorization of the Clean Air Act Amendments of 1990, the air quality in the USA has significantly improved because of strong public support. The lessons learned over the last 25 years are being shared with the policy analysts, technical professionals, and scientist who endeavor to improve air quality in their communities. This paper will review how the USA has achieved the "high" standard of air quality that was envisioned in the early 1990s. This document will describe SO 2 gas emission reduction technology and highlight operation of emission monitoring technology. This paper describes the basic process operation of an air pollution control scrubber. A technical review of measures required to operate and maintain a large-scale pollution control system will be described. Also, the author explains how quality assurance procedures in performance of continuous emission monitoring plays a significant role in reducing air pollution.

  13. Successful integration efforts in water quality from the integrated Ocean Observing System Regional Associations and the National Water Quality Monitoring Network

    USGS Publications Warehouse

    Ragsdale, R.; Vowinkel, E.; Porter, D.; Hamilton, P.; Morrison, R.; Kohut, J.; Connell, B.; Kelsey, H.; Trowbridge, P.

    2011-01-01

    The Integrated Ocean Observing System (IOOS??) Regional Associations and Interagency Partners hosted a water quality workshop in January 2010 to discuss issues of nutrient enrichment and dissolved oxygen depletion (hypoxia), harmful algal blooms (HABs), and beach water quality. In 2007, the National Water Quality Monitoring Council piloted demonstration projects as part of the National Water Quality Monitoring Network (Network) for U.S. Coastal Waters and their Tributaries in three IOOS Regional Associations, and these projects are ongoing. Examples of integrated science-based solutions to water quality issues of major concern from the IOOS regions and Network demonstration projects are explored in this article. These examples illustrate instances where management decisions have benefited from decision-support tools that make use of interoperable data. Gaps, challenges, and outcomes are identified, and a proposal is made for future work toward a multiregional water quality project for beach water quality.

  14. The Development of a Monitoring System of Higher Education Quality in Ukraine and Germany: Comparative Component

    ERIC Educational Resources Information Center

    Chorna, Olga

    2015-01-01

    The article reveals specific features of functioning systems of higher education quality monitoring at the present stage, taking into account national traditions, historical experience and mentality of the population. The article introduces a comparative analysis of monitoring actors at national, regional and local levels in two countries. The…

  15. Data Quality Monitoring System for New GEM Muon Detectors for the CMS Experiment Upgrade

    NASA Astrophysics Data System (ADS)

    King, Robert; CMS Muon Group Team

    2017-01-01

    The Gas Electron Multiplier (GEM) detectors are novel detectors designed to improve the muon trigger and tracking performance in CMS experiment for the high luminosity upgrade of the LHC. Partial installation of GEM detectors is planned during the 2016-2017 technical stop. Before the GEM system is installed underground, its data acquisition (DAQ) electronics must be thoroughly tested. The DAQ system includes several commercial and custom-built electronic boards running custom firmware. The front-end electronics are radiation-hard and communicate via optical fibers. The data quality monitoring (DQM) software framework has been designed to provide online verification of the integrity of the data produced by the detector electronics, and to promptly identify potential hardware or firmware malfunctions in the system. Local hits reconstruction and clustering algorithms allow quality control of the data produced by each GEM chamber. Once the new detectors are installed, the DQM will monitor the stability and performance of the system during normal data-taking operations. We discuss the design of the DQM system, the software being developed to read out and process the detector data, and the methods used to identify and report hardware and firmware malfunctions of the system.

  16. Integrating sentinel watershed-systems into the monitoring and assessment of Minnesota's (USA) waters quality.

    PubMed

    Magner, J A; Brooks, K N

    2008-03-01

    Section 303(d) of the Clean Water Act requires States and Tribes to list waters not meeting water quality standards. A total maximum daily load must be prepared for waters identified as impaired with respect to water quality standards. Historically, the management of pollution in Minnesota has been focused on point-source regulation. Regulatory effort in Minnesota has improved water quality over the last three decades. Non-point source pollution has become the largest driver of conventional 303(d) listings in the 21st century. Conventional pollutants, i.e., organic, sediment and nutrient imbalances can be identified with poor land use management practices. However, the cause and effect relationship can be elusive because of natural watershed-system influences that vary with scale. Elucidation is complex because the current water quality standards in Minnesota were designed to work best with water quality permits to control point sources of pollution. This paper presents a sentinel watershed-systems approach (SWSA) to the monitoring and assessment of Minnesota waterbodies. SWSA integrates physical, chemical, and biological data over space and time using advanced technologies at selected small watersheds across Minnesota to potentially improve understanding of natural and anthropogenic watershed processes and the management of point and non-point sources of pollution. Long-term, state-of-the-art monitoring and assessment is needed to advance and improve water quality standards. Advanced water quality or ecologically-based standards that integrate physical, chemical, and biological numeric criteria offer the potential to better understand, manage, protect, and restore Minnesota's waterbodies.

  17. Georgia's Stream-Water-Quality Monitoring Network, 2006

    USGS Publications Warehouse

    Nobles, Patricia L.; ,

    2006-01-01

    The USGS stream-water-quality monitoring network for Georgia is an aggregation of smaller networks and individual monitoring stations that have been established in cooperation with Federal, State, and local agencies. These networks collectively provide data from 130 sites, 62 of which are monitored continuously in real time using specialized equipment that transmits these data via satellite to a centralized location for processing and storage. These data are made available on the Web in near real time at http://waterdata.usgs.gov/ga/nwis/ Ninety-eight stations are sampled periodically for a more extensive suite of chemical and biological constituents that require laboratory analysis. Both the continuous and the periodic water-quality data are archived and maintained in the USGS National Water Information System and are available to cooperators, water-resource managers, and the public. The map at right shows the USGS stream-water-quality monitoring network for Georgia and major watersheds. The network represents an aggregation of smaller networks and individual monitoring stations that collectively provide data from 130 sites.

  18. Quality Assurance and School Monitoring in Hong Kong

    ERIC Educational Resources Information Center

    Mok, Magdalena Mo Ching

    2007-01-01

    This study reports on the Hong Kong education quality assurance and school monitoring system. Three research questions were addressed: (1) Who controls the quality of school education in Hong Kong? (2) What strategies are used in the Hong Kong school education quality assurance process? (3) Agenda for Future Research on quality assurance and…

  19. Water Quality Monitor

    NASA Technical Reports Server (NTRS)

    1982-01-01

    An automated water quality monitoring system was developed by Langley Research Center to meet a need of the Environmental Protection Agency (EPA). Designed for unattended operation in water depths up to 100 feet, the system consists of a subsurface buoy anchored in the water, a surface control unit (SCU) and a hydrophone link for acoustic communication between buoy and SCU. Primary functional unit is the subsurface buoy. It incorporates 16 cells for water sampling, plus sensors for eight water quality measurements. Buoy contains all the electronic equipment needed for collecting and storing sensor data, including a microcomputer and a memory unit. Power for the electronics is supplied by a rechargeable nickel cadmium battery that is designed to operate for about two weeks. Through hydrophone link the subsurface buoy reports its data to the SCU, which relays it to land stations. Link allows two-way communications. If system encounters a problem, it automatically shuts down and sends alert signal. Sequence of commands sent via hydrophone link causes buoy to release from anchor and float to the surface for recovery.

  20. Environment quality monitoring using ARM processor

    NASA Astrophysics Data System (ADS)

    Vinaya, C. H.; Krishna Thanikanti, Vamsi; Ramasamy, Sudha

    2017-11-01

    This paper of air quality monitoring system describes a model of sensors network to continuously monitoring the environment with low cost developed model. At present time all over the world turned into a great revolution in industrial domain and on the other hand environment get polluting in a dangerous value. There are so many technologies present to reduce the polluting contents but still there is no completely reduction of that pollution. Even there are different methods to monitor the pollution content; these are much costly that not everyone can adapt those methods or devices. Now we are proposing a sensors connected network to monitor the environment continuously and displaying the pollutant gases percentage in air surroundings and can transmit the results to our mobiles by message. The advantage of this system is easy to design, establish at area to monitor, maintenance and most cost effective as well.

  1. In-situ quality monitoring during laser brazing

    NASA Astrophysics Data System (ADS)

    Ungers, Michael; Fecker, Daniel; Frank, Sascha; Donst, Dmitri; Märgner, Volker; Abels, Peter; Kaierle, Stefan

    Laser brazing of zinc coated steel is a widely established manufacturing process in the automotive sector, where high quality requirements must be fulfilled. The strength, impermeablitiy and surface appearance of the joint are particularly important for judging its quality. The development of an on-line quality control system is highly desired by the industry. This paper presents recent works on the development of such a system, which consists of two cameras operating in different spectral ranges. For the evaluation of the system, seam imperfections are created artificially during experiments. Finally image processing algorithms for monitoring process parameters based the captured images are presented.

  2. R2 Water Quality Portal Monitoring Stations

    EPA Pesticide Factsheets

    The Water Quality Data Portal (WQP) provides an easy way to access data stored in various large water quality databases. The WQP provides various input parameters on the form including location, site, sampling, and date parameters to filter and customize the returned results. The The Water Quality Portal (WQP) is a cooperative service sponsored by the United States Geological Survey (USGS), the Environmental Protection Agency (EPA) and the National Water Quality Monitoring Council (NWQMC) that integrates publicly available water quality data from the USGS National Water Information System (NWIS) the EPA STOrage and RETrieval (STORET) Data Warehouse, and the USDA ARS Sustaining The Earth??s Watersheds - Agricultural Research Database System (STEWARDS).

  3. Air Quality System (AQS) Metadata

    EPA Pesticide Factsheets

    The U.S. Environmental Protection Agency compiles air quality monitoring data in the Air Quality System (AQS). Ambient air concentrations are measured at a national network of more than 4,000 monitoring stations and are reported by state, local, and tribal

  4. Source Water Quality Monitoring

    EPA Science Inventory

    Presentation will provide background information on continuous source water monitoring using online toxicity monitors and cover various tools available. Conceptual and practical aspects of source water quality monitoring will be discussed.

  5. Continuous on-line steam quality monitoring system of the Bacman Geothermal Production Field, Philippines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Solis, R.P.; Chavez, F.C.; Garcia, S.E.

    1997-12-31

    In any operating geothermal power plant, steam quality is one of the most important parameters being monitored. In the Bacon-Manito Geothermal Production Field (BGPF), an online steam quality monitoring system have been installed in two operating power plants which provides an accurate, efficient and continuous real-time data which is more responsive to the various requirements of the field operation. The system utilizes sodium as an indicator of steam purity. Sodium concentration is read by the flame photometer located at the interface after aspirating a sample of the condensed steam through a continuous condensate sampler. The condensate has been degassed throughmore » a condensate-NCG separator. The flame photometer analog signal is then converted by a voltage-to-current converter/transmitter and relayed to the processor which is located at the control center through electrical cable to give a digital sodium concentration read-out at the control panel. The system features a high and high-high sodium level alarm, a continuous strip-chart recorder and a central computer for data capture, retrieval, and processing for further interpretation. Safety devices, such as the flame-off indicator at the control center and the automatic fuel cut-off device along the fuel line, are incorporated in the system.« less

  6. A low-cost sensing system for cooperative air quality monitoring in urban areas.

    PubMed

    Brienza, Simone; Galli, Andrea; Anastasi, Giuseppe; Bruschi, Paolo

    2015-05-26

    Air quality in urban areas is a very important topic as it closely affects the health of citizens. Recent studies highlight that the exposure to polluted air can increase the incidence of diseases and deteriorate the quality of life. Hence, it is necessary to develop tools for real-time air quality monitoring, so as to allow appropriate and timely decisions. In this paper, we present uSense, a low-cost cooperative monitoring tool that allows knowing, in real-time, the concentrations of polluting gases in various areas of the city. Specifically, users monitor the areas of their interest by deploying low-cost and low-power sensor nodes. In addition, they can share the collected data following a social networking approach. uSense has been tested through an in-field experimentation performed in different areas of a city. The obtained results are in line with those provided by the local environmental control authority and show that uSense can be profitably used for air quality monitoring.

  7. Gas House Autonomous System Monitoring

    NASA Technical Reports Server (NTRS)

    Miller, Luke; Edsall, Ashley

    2015-01-01

    Gas House Autonomous System Monitoring (GHASM) will employ Integrated System Health Monitoring (ISHM) of cryogenic fluids in the High Pressure Gas Facility at Stennis Space Center. The preliminary focus of development incorporates the passive monitoring and eventual commanding of the Nitrogen System. ISHM offers generic system awareness, adept at using concepts rather than specific error cases. As an enabler for autonomy, ISHM provides capabilities inclusive of anomaly detection, diagnosis, and abnormality prediction. Advancing ISHM and Autonomous Operation functional capabilities enhances quality of data, optimizes safety, improves cost effectiveness, and has direct benefits to a wide spectrum of aerospace applications.

  8. Water quality monitor. [spacecraft potable water

    NASA Technical Reports Server (NTRS)

    West, S.; Crisos, J.; Baxter, W.

    1979-01-01

    The preprototype water quality monitor (WQM) subsystem was designed based on a breadboard monitor for pH, specific conductance, and total organic carbon (TOC). The breadboard equipment demonstrated the feasibility of continuous on-line analysis of potable water for a spacecraft. The WQM subsystem incorporated these breadboard features and, in addition, measures ammonia and includes a failure detection system. The sample, reagent, and standard solutions are delivered to the WQM sensing manifold where chemical operations and measurements are performed using flow through sensors for conductance, pH, TOC, and NH3. Fault monitoring flow detection is also accomplished in this manifold assembly. The WQM is designed to operate automatically using a hardwired electronic controller. In addition, automatic shutdown is incorporated which is keyed to four flow sensors strategically located within the fluid system.

  9. Integrated photovoltaic (PV) monitoring system

    NASA Astrophysics Data System (ADS)

    Mahinder Singh, Balbir Singh; Husain, NurSyahidah; Mohamed, Norani Muti

    2012-09-01

    The main aim of this research work is to design an accurate and reliable monitoring system to be integrated with solar electricity generating system. The performance monitoring system is required to ensure that the PVEGS is operating at an optimum level. The PV monitoring system is able to measure all the important parameters that determine an optimum performance. The measured values are recorded continuously, as the data acquisition system is connected to a computer, and data is stored at fixed intervals. The data can be locally used and can also be transmitted via internet. The data that appears directly on the local monitoring system is displayed via graphical user interface that was created by using Visual basic and Apache software was used for data transmission The accuracy and reliability of the developed monitoring system was tested against the data that captured simultaneously by using a standard power quality analyzer device. The high correlation which is 97% values indicates the level of accuracy of the monitoring system. The aim of leveraging on a system for continuous monitoring system is achieved, both locally, and can be viewed simultaneously at a remote system.

  10. In-pipe water quality monitoring in water supply systems under steady and unsteady state flow conditions: a quantitative assessment.

    PubMed

    Aisopou, Angeliki; Stoianov, Ivan; Graham, Nigel J D

    2012-01-01

    Monitoring the quality of drinking water from the treatment plant to the consumers tap is critical to ensure compliance with national standards and/or WHO guideline levels. There are a number of processes and factors affecting the water quality during transmission and distribution which are little understood. A significant obstacle for gaining a detailed knowledge of various physical and chemical processes and the effect of the hydraulic conditions on the water quality deterioration within water supply systems is the lack of reliable and low-cost (both capital and O & M) water quality sensors for continuous monitoring. This paper has two objectives. The first one is to present a detailed evaluation of the performance of a novel in-pipe multi-parameter sensor probe for reagent- and membrane-free continuous water quality monitoring in water supply systems. The second objective is to describe the results from experimental research which was conducted to acquire continuous water quality and high-frequency hydraulic data for the quantitative assessment of the water quality changes occurring under steady and unsteady-state flow conditions. The laboratory and field evaluation of the multi-parameter sensor probe showed that the sensors have a rapid dynamic response, average repeatability and unreliable accuracy. The uncertainties in the sensor data present significant challenges for the analysis and interpretation of the acquired data and their use for water quality modelling, decision support and control in operational systems. Notwithstanding these uncertainties, the unique data sets acquired from transmission and distribution systems demonstrated the deleterious effect of unsteady state flow conditions on various water quality parameters. These studies demonstrate: (i) the significant impact of the unsteady-state hydraulic conditions on the disinfectant residual, turbidity and colour caused by the re-suspension of sediments, scouring of biofilms and tubercles from the

  11. ChronQC: a quality control monitoring system for clinical next generation sequencing.

    PubMed

    Tawari, Nilesh R; Seow, Justine Jia Wen; Perumal, Dharuman; Ow, Jack L; Ang, Shimin; Devasia, Arun George; Ng, Pauline C

    2018-05-15

    ChronQC is a quality control (QC) tracking system for clinical implementation of next-generation sequencing (NGS). ChronQC generates time series plots for various QC metrics to allow comparison of current runs to historical runs. ChronQC has multiple features for tracking QC data including Westgard rules for clinical validity, laboratory-defined thresholds and historical observations within a specified time period. Users can record their notes and corrective actions directly onto the plots for long-term recordkeeping. ChronQC facilitates regular monitoring of clinical NGS to enable adherence to high quality clinical standards. ChronQC is freely available on GitHub (https://github.com/nilesh-tawari/ChronQC), Docker (https://hub.docker.com/r/nileshtawari/chronqc/) and the Python Package Index. ChronQC is implemented in Python and runs on all common operating systems (Windows, Linux and Mac OS X). tawari.nilesh@gmail.com or pauline.c.ng@gmail.com. Supplementary data are available at Bioinformatics online.

  12. Online Toxicity Monitors (OTM) for Distribution System Water Quality Monitoring

    EPA Science Inventory

    Drinking water distribution systems in the U.S. are vulnerable to episodic contamination events (both unintentional and intentional). The U.S. Environmental Protection Agency (EPA) is conducting research to investigate the use of broad-spectrum online toxicity monitors (OTMs) in ...

  13. Clinical applications of commercially available video recording and monitoring systems: inexpensive, high-quality video recording and monitoring systems for endoscopy and microsurgery.

    PubMed

    Tsunoda, Koichi; Tsunoda, Atsunobu; Ishimoto, ShinnIchi; Kimura, Satoko

    2006-01-01

    The exclusive charge-coupled device (CCD) camera system for the endoscope and electronic fiberscopes are in widespread use. However, both are usually stationary in an office or examination room, and a wheeled cart is needed for mobility. The total costs of the CCD camera system and electronic fiberscopy system are at least US Dollars 10,000 and US Dollars 30,000, respectively. Recently, the performance of audio and visual instruments has improved dramatically, with a concomitant reduction in their cost. Commercially available CCD video cameras with small monitors have become common. They provide excellent image quality and are much smaller and less expensive than previous models. The authors have developed adaptors for the popular mini-digital video (mini-DV) camera. The camera also provides video and acoustic output signals; therefore, the endoscopic images can be viewed on a large monitor simultaneously. The new system (a mini-DV video camera and an adaptor) costs only US Dollars 1,000. Therefore, the system is both cost-effective and useful for the outpatient clinic or casualty setting, or on house calls for the purpose of patient education. In the future, the authors plan to introduce the clinical application of a high-vision camera and an infrared camera as medical instruments for clinical and research situations.

  14. Analytical chemistry in water quality monitoring during manned space missions

    NASA Astrophysics Data System (ADS)

    Artemyeva, Anastasia A.

    2016-09-01

    Water quality monitoring during human spaceflights is essential. However, most of the traditional methods require sample collection with a subsequent ground analysis because of the limitations in volume, power, safety and gravity. The space missions are becoming longer-lasting; hence methods suitable for in-flight monitoring are demanded. Since 2009, water quality has been monitored in-flight with colorimetric methods allowing for detection of iodine and ionic silver. Organic compounds in water have been monitored with a second generation total organic carbon analyzer, which provides information on the amount of carbon in water at both the U.S. and Russian segments of the International Space Station since 2008. The disadvantage of this approach is the lack of compound-specific information. The recently developed methods and tools may potentially allow one to obtain in-flight a more detailed information on water quality. Namely, the microanalyzers based on potentiometric measurements were designed for online detection of chloride, potassium, nitrate ions and ammonia. The recent application of the current highly developed air quality monitoring system for water analysis was a logical step because most of the target analytes are the same in air and water. An electro-thermal vaporizer was designed, manufactured and coupled with the air quality control system. This development allowed for liberating the analytes from the aqueous matrix and further compound-specific analysis in the gas phase.

  15. Real-time water quality monitoring and providing water quality ...

    EPA Pesticide Factsheets

    EPA and the U.S. Geological Survey (USGS) have initiated the “Village Blue” research project to provide real-time water quality monitoring data to the Baltimore community and increase public awareness about local water quality in Baltimore Harbor and the Chesapeake Bay. The Village Blue demonstration project complements work that a number of state and local organizations are doing to make Baltimore Harbor “swimmable and fishable” 2 by 2020. Village Blue is designed to build upon EPA’s “Village Green” project which provides real-time air quality information to communities in six locations across the country. The presentation, “Real-time water quality monitoring and providing water quality information to the Baltimore Community”, summarizes the Village Blue real-time water quality monitoring project being developed for the Baltimore Harbor.

  16. Quality control of CT systems by automated monitoring of key performance indicators: a two‐year study

    PubMed Central

    Bujila, Robert; Poludniowski, Gavin; Fransson, Annette

    2015-01-01

    The purpose of this study was to develop a method of performing routine periodical quality controls (QC) of CT systems by automatically analyzing key performance indicators (KPIs), obtainable from images of manufacturers' quality assurance (QA) phantoms. A KPI pertains to a measurable or determinable QC parameter that is influenced by other underlying fundamental QC parameters. The established KPIs are based on relationships between existing QC parameters used in the annual testing program of CT scanners at the Karolinska University Hospital in Stockholm, Sweden. The KPIs include positioning, image noise, uniformity, homogeneity, the CT number of water, and the CT number of air. An application (MonitorCT) was developed to automatically evaluate phantom images in terms of the established KPIs. The developed methodology has been used for two years in clinical routine, where CT technologists perform daily scans of the manufacturer's QA phantom and automatically send the images to MonitorCT for KPI evaluation. In the cases where results were out of tolerance, actions could be initiated in less than 10 min. 900 QC scans from two CT scanners have been collected and analyzed over the two‐year period that MonitorCT has been active. Two types of errors have been registered in this period: a ring artifact was discovered with the image noise test, and a calibration error was detected multiple times with the CT number test. In both cases, results were outside the tolerances defined for MonitorCT, as well as by the vendor. Automated monitoring of KPIs is a powerful tool that can be used to supplement established QC methodologies. Medical physicists and other professionals concerned with the performance of a CT system will, using such methods, have access to comprehensive data on the current and historical (trend) status of the system such that swift actions can be taken in order to ensure the quality of the CT examinations, patient safety, and minimal disruption of service

  17. Quality control of CT systems by automated monitoring of key performance indicators: a two-year study.

    PubMed

    Nowik, Patrik; Bujila, Robert; Poludniowski, Gavin; Fransson, Annette

    2015-07-08

    The purpose of this study was to develop a method of performing routine periodical quality controls (QC) of CT systems by automatically analyzing key performance indicators (KPIs), obtainable from images of manufacturers' quality assurance (QA) phantoms. A KPI pertains to a measurable or determinable QC parameter that is influenced by other underlying fundamental QC parameters. The established KPIs are based on relationships between existing QC parameters used in the annual testing program of CT scanners at the Karolinska University Hospital in Stockholm, Sweden. The KPIs include positioning, image noise, uniformity, homogeneity, the CT number of water, and the CT number of air. An application (MonitorCT) was developed to automatically evaluate phantom images in terms of the established KPIs. The developed methodology has been used for two years in clinical routine, where CT technologists perform daily scans of the manufacturer's QA phantom and automatically send the images to MonitorCT for KPI evaluation. In the cases where results were out of tolerance, actions could be initiated in less than 10 min. 900 QC scans from two CT scanners have been collected and analyzed over the two-year period that MonitorCT has been active. Two types of errors have been registered in this period: a ring artifact was discovered with the image noise test, and a calibration error was detected multiple times with the CT number test. In both cases, results were outside the tolerances defined for MonitorCT, as well as by the vendor. Automated monitoring of KPIs is a powerful tool that can be used to supplement established QC methodologies. Medical physicists and other professionals concerned with the performance of a CT system will, using such methods, have access to comprehensive data on the current and historical (trend) status of the system such that swift actions can be taken in order to ensure the quality of the CT examinations, patient safety, and minimal disruption of service.

  18. Assessment of polycarbonate filter in a molecular analytical system for the microbiological quality monitoring of recycled waters onboard ISS.

    PubMed

    Bechy-Loizeau, Anne-Laure; Flandrois, Jean-Pierre; Abaibou, Hafid

    2015-07-01

    On the ISS, as on Earth, water is an essential element for life and its quality control on a regular basis allows to ensure the health of the crew and the integrity of equipment. Currently, microbial water analysis onboard ISS still relies on the traditional culture-based microbiology methods. Molecular methods based on the amplification of nucleic acids for microbiological analysis of water quality show enormous potential and are considered as the best alternative to culture-based methods. For this reason, the Midass, a fully integrated and automated prototype was designed conjointly by ESA and bioMérieux for a rapid monitoring of the microbiological quality of air. The prototype allows air sampling, sample processing and the amplification/detection of nucleic acids. We describe herein the proof of principle of an analytical approach based on molecular biology that could fulfill the ESA's need for a rapid monitoring of the microbiological quality of recycled water onboard ISS. Both concentration and recovery of microorganisms are the main critical steps when the microfiltration technology is used for water analysis. Among filters recommended standards for monitoring the microbiological quality of the water, the polycarbonate filter was fully in line with the requirements of the ISO 7704-1985 standard in terms of efficacy of capture and recovery of bacteria. Moreover, this filter does not retain nucleic acids on the surface and has no inhibitory effect on their downstream processing steps such as purification and amplification/detection. Although the Midass system was designed for the treatment of air samples, the first results on the integration of PC filters were encouraging. Nevertheless, system modifications are needed to better adapt the Midass system for the monitoring of the microbiological water quality. Copyright © 2015 The Committee on Space Research (COSPAR). Published by Elsevier Ltd. All rights reserved.

  19. A conceptual ground-water-quality monitoring network for San Fernando Valley, California

    USGS Publications Warehouse

    Setmire, J.G.

    1985-01-01

    A conceptual groundwater-quality monitoring network was developed for San Fernando Valley to provide the California State Water Resources Control Board with an integrated, basinwide control system to monitor the quality of groundwater. The geology, occurrence and movement of groundwater, land use, background water quality, and potential sources of pollution were described and then considered in designing the conceptual monitoring network. The network was designed to monitor major known and potential point and nonpoint sources of groundwater contamination over time. The network is composed of 291 sites where wells are needed to define the groundwater quality. The ideal network includes four specific-purpose networks to monitor (1) ambient water quality, (2) nonpoint sources of pollution, (3) point sources of pollution, and (4) line sources of pollution. (USGS)

  20. Air Quality Monitoring: Risk-Based Choices

    NASA Technical Reports Server (NTRS)

    James, John T.

    2009-01-01

    Air monitoring is secondary to rigid control of risks to air quality. Air quality monitoring requires us to target the credible residual risks. Constraints on monitoring devices are severe. Must transition from archival to real-time, on-board monitoring. Must provide data to crew in a way that they can interpret findings. Dust management and monitoring may be a major concern for exploration class missions.

  1. Real-time video quality monitoring

    NASA Astrophysics Data System (ADS)

    Liu, Tao; Narvekar, Niranjan; Wang, Beibei; Ding, Ran; Zou, Dekun; Cash, Glenn; Bhagavathy, Sitaram; Bloom, Jeffrey

    2011-12-01

    The ITU-T Recommendation G.1070 is a standardized opinion model for video telephony applications that uses video bitrate, frame rate, and packet-loss rate to measure the video quality. However, this model was original designed as an offline quality planning tool. It cannot be directly used for quality monitoring since the above three input parameters are not readily available within a network or at the decoder. And there is a great room for the performance improvement of this quality metric. In this article, we present a real-time video quality monitoring solution based on this Recommendation. We first propose a scheme to efficiently estimate the three parameters from video bitstreams, so that it can be used as a real-time video quality monitoring tool. Furthermore, an enhanced algorithm based on the G.1070 model that provides more accurate quality prediction is proposed. Finally, to use this metric in real-world applications, we present an example emerging application of real-time quality measurement to the management of transmitted videos, especially those delivered to mobile devices.

  2. Water monitor system: Phase 1 test report

    NASA Technical Reports Server (NTRS)

    Taylor, R. E.; Jeffers, E. L.

    1976-01-01

    Automatic water monitor system was tested with the objectives of assuring high-quality effluent standards and accelerating the practice of reclamation and reuse of water. The NASA water monitor system is described. Various components of the system, including the necessary sensors, the sample collection system, and the data acquisition and display system, are discussed. The test facility and the analysis methods are described. Test results are reviewed, and recommendations for water monitor system design improvement are presented.

  3. Monitoring and modeling of microbial and biological water quality

    USDA-ARS?s Scientific Manuscript database

    Microbial and biological water quality informs on the health of water systems and their suitability for uses in irrigation, recreation, aquaculture, and other activities. Indicators of microbial and biological water quality demonstrate high spatial and temporal variability. Therefore, monitoring str...

  4. Atmosphere and water quality monitoring on Space Station Freedom

    NASA Technical Reports Server (NTRS)

    Niu, William

    1990-01-01

    In Space Station Freedom air and water will be supplied in closed loop systems. The monitoring of air and water qualities will ensure the crew health for the long mission duration. The Atmosphere Composition Monitor consists of the following major instruments: (1) a single focusing mass spectrometer to monitor major air constituents and control the oxygen/nitrogen addition for the Space Station; (2) a gas chromatograph/mass spectrometer to detect trace contaminants; (3) a non-dispersive infrared spectrometer to determine carbon monoxide concentration; and (4) a laser particle counter for measuring particulates in the air. An overview of the design and development concepts for the air and water quality monitors is presented.

  5. Development of digital rectangular phantoms for quality controls of medical primary monitors in RIS-PACS systems

    NASA Astrophysics Data System (ADS)

    Mattacchioni, A.; Cristianini, M.; Lo Bosco, A.

    2013-03-01

    The purpose of this paper is to project digital rectangular phantoms, Di.Recta Multipurpose Phantoms (Di.Recta MP) for quality controls of primary high resolution medical monitors. The first approach for the monitors quality evaluation is represented by AAPM tests using multipurpose TG-18- CQ phantoms. The TG18-QC patterns are available in two sizes: 1024x1024 and 2048x2048 and the use of these phantoms requires a correct monitor setup. The study demonstrates that this type of phantoms is suitable for CRT monitors with adequate settings procedures. In the second step LCD monitors are analysed. Different types of primary monitors are included in a range between 2 and 5 Mp. The difference between the resolution of monitors and phantoms does not allow a complete analysis of the entire system, just moving phantoms in different positions. Of course, the analysis of images in the peripheral regions of medical monitors can not be neglected, especially because of the possible legal implications. A simpler analysis of these areas can be done through the use of rectangular phantoms in place of square ones. Furthermore, because of different technology, also different analysis patches are necessary for these types of monitors. Therefore, there are proposed digital rectangular phantoms, Di.Recta MP, compatible with the spatial resolution of most of commercial monitors. These phantoms are designed to simulate typical radiological conditions to determine the presence of significant defects using appropriate patches such as luminance, contrast, noise patterns. Finally a preliminary study of dedicate Di.Recta MP are proposed for LED monitors.

  6. Monitoring Quality Across Home Visiting Models: A Field Test of Michigan's Home Visiting Quality Assurance System.

    PubMed

    Heany, Julia; Torres, Jennifer; Zagar, Cynthia; Kostelec, Tiffany

    2018-06-05

    Introduction In order to achieve the positive outcomes with parents and children demonstrated by many home visiting models, home visiting services must be well implemented. The Michigan Home Visiting Initiative developed a tool and procedure for monitoring implementation quality across models referred to as Michigan's Home Visiting Quality Assurance System (MHVQAS). This study field tested the MHVQAS. This article focuses on one of the study's evaluation questions: Can the MHVQAS be applied across models? Methods Eight local implementing agencies (LIAs) from four home visiting models (Healthy Families America, Early Head Start-Home Based, Parents as Teachers, Maternal Infant Health Program) and five reviewers participated in the study by completing site visits, tracking their time and costs, and completing surveys about the process. LIAs also submitted their most recent review by their model developer. The researchers conducted participant observation of the review process. Results Ratings on the MHVQAS were not significantly different between models. There were some differences in interrater reliability and perceived reliability between models. There were no significant differences between models in perceived validity, satisfaction with the review process, or cost to participate. Observational data suggested that cross-model applicability could be improved by assisting sites in relating the requirements of the tool to the specifics of their model. Discussion The MHVQAS shows promise as a tool and process to monitor implementation quality of home visiting services across models. The results of the study will be used to make improvements before the MHVQAS is used in practice.

  7. Definition of air quality measurements for monitoring space shuttle launches

    NASA Technical Reports Server (NTRS)

    Thorpe, R. D.

    1978-01-01

    A description of a recommended air quality monitoring network to characterize the impact on ambient air quality in the Kennedy Space Center (KSC) (area) of space shuttle launch operations is given. Analysis of ground cloud processes and prevalent meteorological conditions indicates that transient HCl depositions can be a cause for concern. The system designed to monitor HCl employs an extensive network of inexpensive detectors combined with a central analysis device. An acid rain network is also recommended. A quantitative measure of projected minimal long-term impact involves the limited monitoring of NOx and particulates. All recommended monitoring is confined ti KSC property.

  8. The strategy for improving water-quality monitoring in the United States; final report of the Intergovernmental Task Force on Monitoring Water Quality; technical appendices

    USGS Publications Warehouse

    ,

    1995-01-01

    The Intergovernmental Task Force on Monitoring Water Quality (ITFM) prepared this report in collaboration with representatives of all levels of government and the private sector. The report recommends a strategy for nationwide water-quality monitoring and technical monitoring improvements to support sound water-quality decisionmaking. The strategy is intended to achieve a better return on public and private investments in monitoring, environmental protection, and natural resources management. It is also designed to expand the base of information useful to a variety of users at multiple geographic scales. Institutional and technical changes are needed to improve water-quality monitoring and to meet the full range of monitoring requirements. Monitoring must be incorporated as a critical element of program planning, implementation, and evaluation. The strategy includes recommendations in many key elements, such as the development of goal-oriented monitoring and indicators, institutional collaboration, and methods comparability. Initial actions have been taken to implement the strategy. Several Federal agencies have jointly purchased and shared remotely sensed land-cover information needed for water assessment. Major agency data systems are using common data-element names and reference tables that will ensure easy sharing of data. A number of States have held meetings with collectors of water information to initiate statewide monitoring strategies. New monitoring guidance has been developed for Federal water-quality grants to States. Many State offices have changed monitoring programs to place emphasis on priority watersheds and to improve assessment of water quality. As the competition increases for adequate supplies of clean water, concerns about public health and the environment escalate, and more demands are placed on the water information infrastructure. To meet these demands, the collaborative approach has already produced benefits, which will continue to grow as

  9. Software requirements elicitation to support internal monitoring of quality assurance system for higher education in Indonesia

    NASA Astrophysics Data System (ADS)

    Amalia, A.; Gunawan, D.; Hardi, S. M.; Rachmawati, D.

    2018-02-01

    The Internal Quality Assurance System (in Indonesian: SPMI (Sistem Penjaminan Mutu Internal) is a systemic activity of quality assurance of higher education in Indonesia. SPMI should be done by all higher education or universities in Indonesia based on the Regulation of the Minister of Research, Technology and Higher Education of the Republic of Indonesia Number 62 of 2016. Implementation of SPMI must refer to the principle of SPMI that is independent, standardize, accurate, well planned and sustainable, documented and systematic. To assist the SPMI cycle properly, universities need a supporting software to monitor all the activities of SPMI. But in reality, many universities are not optimal in building this SPMI monitoring system. One of the obstacles is the determination of system requirements in support of SPMI principles is difficult to achieve. In this paper, we observe the initial phase of the engineering requirements elicitation. Unlike other methods that collect system requirements from users and stakeholders, we find the system requirements of the SPMI principles from SPMI guideline book. The result of this paper can be used as a choice in determining SPMI software requirements. This paper can also be used by developers and users to understand the scenario of SPMI so that could overcome the problems of understanding between this two parties.

  10. Development of sleep monitoring system for observing the effect of the room ambient toward the quality of sleep

    NASA Astrophysics Data System (ADS)

    Saad, W. H. M.; Khoo, C. W.; Rahman, S. I. Ab; Ibrahim, M. M.; Saad, N. H. M.

    2017-06-01

    Getting enough sleep at the right times can help in improving quality of life and protect mental and physical health. This study proposes a portable sleep monitoring device to determine the relationship between the room ambient and quality of sleep. Body condition parameter such as heart rate, body temperature and body movement was used to determine quality of sleep and Audio/video-based monitoring system. The functionality test on all sensors is carried out to make sure that all sensors is working properly. The functionality of the overall system is designed for a better experience with a very minimal intervention to the user. The simple test on the body condition (body temperature and heart rate) while asleep with several different ambient parameters (humidity, brightness and temperature) are varied and the result shows that someone has a better sleep in a dark and colder ambient. This can prove by lower body temperature and lower heart rate.

  11. Fuzzy intelligent quality monitoring model for X-ray image processing.

    PubMed

    Khalatbari, Azadeh; Jenab, Kouroush

    2009-01-01

    Today's imaging diagnosis needs to adapt modern techniques of quality engineering to maintain and improve its accuracy and reliability in health care system. One of the main factors that influences diagnostic accuracy of plain film X-ray on detecting pathology is the level of film exposure. If the level of film exposure is not adequate, a normal body structure may be interpretated as pathology and vice versa. This not only influences the patient management but also has an impact on health care cost and patient's quality of life. Therefore, providing an accurate and high quality image is the first step toward an excellent patient management in any health care system. In this paper, we study these techniques and also present a fuzzy intelligent quality monitoring model, which can be used to keep variables from degrading the image quality. The variables derived from chemical activity, cleaning procedures, maintenance, and monitoring may not be sensed, measured, or calculated precisely due to uncertain situations. Therefore, the gamma-level fuzzy Bayesian model for quality monitoring of an image processing is proposed. In order to apply the Bayesian concept, the fuzzy quality characteristics are assumed as fuzzy random variables. Using the fuzzy quality characteristics, the newly developed model calculates the degradation risk for image processing. A numerical example is also presented to demonstrate the application of the model.

  12. Distributed intelligent urban environment monitoring system

    NASA Astrophysics Data System (ADS)

    Du, Jinsong; Wang, Wei; Gao, Jie; Cong, Rigang

    2018-02-01

    The current environmental pollution and destruction have developed into a world-wide major social problem that threatens human survival and development. Environmental monitoring is the prerequisite and basis of environmental governance, but overall, the current environmental monitoring system is facing a series of problems. Based on the electrochemical sensor, this paper designs a small, low-cost, easy to layout urban environmental quality monitoring terminal, and multi-terminal constitutes a distributed network. The system has been small-scale demonstration applications and has confirmed that the system is suitable for large-scale promotion

  13. Letter Report: Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Caliente, Lincoln County, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. Englebrecht; I. Kavouras; D. Campbell

    2008-08-01

    The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Beatty, Sarcobatus Flats, Rachel, Caliente, Pahranagat NWR, Crater Flat, and Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d).more » The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data, on completion of the site's sampling program.« less

  14. NASA JSC water monitor system: City of Houston field demonstration

    NASA Technical Reports Server (NTRS)

    Taylor, R. E.; Jeffers, E. L.; Fricks, D. H.

    1979-01-01

    A water quality monitoring system with on-line and real time operation similar to the function in a spacecraft was investigated. A system with the capability to determine conformance to future high effluent quality standards and to increase the potential for reclamation and reuse of water was designed. Although all system capabilities were not verified in the initial field trial, fully automated operation over a sustained period with only routine manual adjustments was accomplished. Two major points were demonstrated: (1) the water monitor system has great potential in water monitoring and/or process control applications; and (2) the water monitor system represents a vast improvement over conventional (grab sample) water monitoring techniques.

  15. The future of remote ECG monitoring systems.

    PubMed

    Guo, Shu-Li; Han, Li-Na; Liu, Hong-Wei; Si, Quan-Jin; Kong, De-Feng; Guo, Fu-Su

    2016-09-01

    Remote ECG monitoring systems are becoming commonplace medical devices for remote heart monitoring. In recent years, remote ECG monitoring systems have been applied in the monitoring of various kinds of heart diseases, and the quality of the transmission and reception of the ECG signals during remote process kept advancing. However, there remains accompanying challenges. This report focuses on the three components of the remote ECG monitoring system: patient (the end user), the doctor workstation, and the remote server, reviewing and evaluating the imminent challenges on the wearable systems, packet loss in remote transmission, portable ECG monitoring system, patient ECG data collection system, and ECG signals transmission including real-time processing ST segment, R wave, RR interval and QRS wave, etc. This paper tries to clarify the future developmental strategies of the ECG remote monitoring, which can be helpful in guiding the research and development of remote ECG monitoring.

  16. Pilot evaluation of electricity-reliability and power-quality monitoring in California's Silicon Valley with the I-Grid(R) system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eto, Joseph; Divan, Deepak; Brumsickle, William

    2004-02-01

    Power-quality events are of increasing concern for the economy because today's equipment, particularly computers and automated manufacturing devices, is susceptible to these imperceptible voltage changes. A small variation in voltage can cause this equipment to shut down for long periods, resulting in significant business losses. Tiny variations in power quality are difficult to detect except with expensive monitoring equipment used by trained technicians, so many electricity customers are unaware of the role of power-quality events in equipment malfunctioning. This report describes the findings from a pilot study coordinated through the Silicon Valley Manufacturers Group in California to explore the capabilitiesmore » of I-Grid(R), a new power-quality monitoring system. This system is designed to improve the accessibility of power-quality in formation and to increase understanding of the growing importance of electricity reliability and power quality to the economy. The study used data collected by I-Grid sensors at seven Silicon Valley firms to investigate the impacts of power quality on individual study participants as well as to explore the capabilities of the I-Grid system to detect events on the larger electricity grid by means of correlation of data from the sensors at the different sites. In addition, study participants were interviewed about the value they place on power quality, and their efforts to address electricity-reliability and power-quality problems. Issues were identified that should be taken into consideration in developing a larger, potentially nationwide, network of power-quality sensors.« less

  17. Improved quality monitoring of multi-center acupuncture clinical trials in China

    PubMed Central

    2009-01-01

    Background In 2007, the Chinese Science Division of the State Administration of Traditional Chinese Medicine(TCM) convened a special conference to discuss quality control for TCM clinical research. Control and assurance standards were established to guarantee the quality of clinical research. This paper provides practical guidelines for implementing strict and reproducible quality control for acupuncture randomized controlled trials (RCTs). Methods A standard quality control program (QCP) was established to monitor the quality of acupuncture trials. Case report forms were designed; qualified investigators, study personnel and data management personnel were trained. Monitors, who were directly appointed by the project leader, completed the quality control programs. They guaranteed data accuracy and prevented or detected protocol violations. Clinical centers and clinicians were audited, the randomization system of the centers was inspected, and the treatment processes were audited as well. In addition, the case report forms were reviewed for completeness and internal consistency, the eligibility and validity of the patients in the study was verified, and data was monitored for compliance and accuracy. Results and discussion The monitors complete their reports and submit it to quality assurance and the sponsors. Recommendations and suggestions are made for improving performance. By holding regular meetings to discuss improvements in monitoring standards, the monitors can improve quality and efficiency. Conclusions Supplementing and improving the existed guidelines for quality monitoring will ensure that large multi-centre acupuncture clinical trials will be considered as valid and scientifically stringent as pharmaceutical clinical trials. It will also develop academic excellence and further promote the international recognition of acupuncture. PMID:20035630

  18. Advances in on-line drinking water quality monitoring and early warning systems.

    PubMed

    Storey, Michael V; van der Gaag, Bram; Burns, Brendan P

    2011-01-01

    Significant advances have been made in recent years in technologies to monitor drinking water quality for source water protection, treatment operations, and distribution system management, in the event of accidental (or deliberate) contamination. Reports prepared through the Global Water Research Coalition (GWRC) and United States Environment Protection Agency (USEPA) agree that while many emerging technologies show promise, they are still some years from being deployed on a large scale. Further underpinning their viability is a need to interpret data in real time and implement a management strategy in response. This review presents the findings of an international study into the state of the art in this field. These results are based on visits to leading water utilities, research organisations and technology providers throughout Europe, the United States and Singapore involved in the development and deployment of on-line monitoring technology for the detection of contaminants in water. Copyright © 2010 Elsevier Ltd. All rights reserved.

  19. Quality management system and accreditation of the in vivo monitoring laboratory at Karslruhe Institute of Technology.

    PubMed

    Breustedt, B; Mohr, U; Biegard, N; Cordes, G

    2011-03-01

    The in vivo monitoring laboratory (IVM) at Karlsruhe Institute of Technology (KIT), with one whole body counter and three partial-body counters, is an approved lab for individual monitoring according to German regulation. These approved labs are required to prove their competencies by accreditation to ISO/IEC 17025:2005. In 2007 a quality management system (QMS), which was successfully audited and granted accreditation, was set up at the IVM. The system is based on the ISO 9001 certified QMS of the central safety department of the Research Centre Karlsruhe the IVM belonged to at that time. The system itself was set up to be flexible and could be adapted to the recent organisational changes (e.g. founding of KIT and an institute for radiation research) with only minor effort.

  20. Portable Mass Spectrometer System for in-situ Environmental Gas Monitoring

    NASA Technical Reports Server (NTRS)

    Conejo, E.; Griffin, T. P.; Diaz, J. A.; Arkin, C. R.; Soto, C.; Naylor, G. R.; Curley, C.; Floyd, D.

    2005-01-01

    A system developed by NASA has been used for monitoring air quality around different locations. The system was designed for aircraft applications but has proven to be very useful as a portable gas analyzer. The system has been used to monitor air quality around volcanoes, cities, and the surrounding areas. The transport of the system has been via aircraft, car, and hand carried.

  1. 40 CFR 97.432 - Monitoring system out-of-control periods.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... monitoring system fails to meet the quality-assurance and quality-control requirements or data validation requirements of part 75 of this chapter, data shall be substituted using the applicable missing data procedures... prospectively the certification status of the monitoring system. The data measured and recorded by the...

  2. 40 CFR 97.432 - Monitoring system out-of-control periods.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... monitoring system fails to meet the quality-assurance and quality-control requirements or data validation requirements of part 75 of this chapter, data shall be substituted using the applicable missing data procedures... prospectively the certification status of the monitoring system. The data measured and recorded by the...

  3. 40 CFR 97.432 - Monitoring system out-of-control periods.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... monitoring system fails to meet the quality-assurance and quality-control requirements or data validation requirements of part 75 of this chapter, data shall be substituted using the applicable missing data procedures... prospectively the certification status of the monitoring system. The data measured and recorded by the...

  4. A hydrologic retention system and water quality monitoring program for a human decomposition research facility: concept and design.

    PubMed

    Wozniak, Jeffrey R; Thies, Monte L; Bytheway, Joan A; Lutterschmidt, William I

    2015-01-01

    Forensic taphonomy is an essential research field; however, the decomposition of human cadavers at forensic science facilities may lead to nutrient loading and the introduction of unique biological compounds to adjacent areas. The infrastructure of a water retention system may provide a mechanism for the biogeochemical processing and retention of nutrients and compounds, ensuring the control of runoff from forensic facilities. This work provides a proof of concept for a hydrologic retention system and an autonomous water quality monitoring program designed to mitigate runoff from The Southeast Texas Applied Forensic Science (STAFS) Facility. Water samples collected along a sample transect were analyzed for total phosphorous, total nitrogen, NO3-, NO2-, NH4, F(-), and Cl(-). Preliminary water quality analyses confirm the overall effectiveness of the water retention system. These results are discussed with relation to how this infrastructure can be expanded upon to monitor additional, more novel, byproducts of forensic science research facilities. © 2014 American Academy of Forensic Sciences.

  5. 40 CFR 130.4 - Water quality monitoring.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... QUALITY PLANNING AND MANAGEMENT § 130.4 Water quality monitoring. (a) In accordance with section 106(e)(1...; developing and reviewing water quality standards, total maximum daily loads, wasteload allocations and load... 40 Protection of Environment 21 2010-07-01 2010-07-01 false Water quality monitoring. 130.4...

  6. 40 CFR 130.4 - Water quality monitoring.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... QUALITY PLANNING AND MANAGEMENT § 130.4 Water quality monitoring. (a) In accordance with section 106(e)(1...; developing and reviewing water quality standards, total maximum daily loads, wasteload allocations and load... 40 Protection of Environment 22 2011-07-01 2011-07-01 false Water quality monitoring. 130.4...

  7. Sampling frequency for water quality variables in streams: Systems analysis to quantify minimum monitoring rates.

    PubMed

    Chappell, Nick A; Jones, Timothy D; Tych, Wlodek

    2017-10-15

    Insufficient temporal monitoring of water quality in streams or engineered drains alters the apparent shape of storm chemographs, resulting in shifted model parameterisations and changed interpretations of solute sources that have produced episodes of poor water quality. This so-called 'aliasing' phenomenon is poorly recognised in water research. Using advances in in-situ sensor technology it is now possible to monitor sufficiently frequently to avoid the onset of aliasing. A systems modelling procedure is presented allowing objective identification of sampling rates needed to avoid aliasing within strongly rainfall-driven chemical dynamics. In this study aliasing of storm chemograph shapes was quantified by changes in the time constant parameter (TC) of transfer functions. As a proportion of the original TC, the onset of aliasing varied between watersheds, ranging from 3.9-7.7 to 54-79 %TC (or 110-160 to 300-600 min). However, a minimum monitoring rate could be identified for all datasets if the modelling results were presented in the form of a new statistic, ΔTC. For the eight H + , DOC and NO 3 -N datasets examined from a range of watershed settings, an empirically-derived threshold of 1.3(ΔTC) could be used to quantify minimum monitoring rates within sampling protocols to avoid artefacts in subsequent data analysis. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  8. A Survey on Data Quality for Dependable Monitoring in Wireless Sensor Networks

    PubMed Central

    Oliveira, Anabela

    2017-01-01

    Wireless sensor networks are being increasingly used in several application areas, particularly to collect data and monitor physical processes. Non-functional requirements, like reliability, security or availability, are often important and must be accounted for in the application development. For that purpose, there is a large body of knowledge on dependability techniques for distributed systems, which provide a good basis to understand how to satisfy these non-functional requirements of WSN-based monitoring applications. Given the data-centric nature of monitoring applications, it is of particular importance to ensure that data are reliable or, more generically, that they have the necessary quality. In this survey, we look into the problem of ensuring the desired quality of data for dependable monitoring using WSNs. We take a dependability-oriented perspective, reviewing the possible impairments to dependability and the prominent existing solutions to solve or mitigate these impairments. Despite the variety of components that may form a WSN-based monitoring system, we give particular attention to understanding which faults can affect sensors, how they can affect the quality of the information and how this quality can be improved and quantified. PMID:28869505

  9. A Survey on Data Quality for Dependable Monitoring in Wireless Sensor Networks.

    PubMed

    Jesus, Gonçalo; Casimiro, António; Oliveira, Anabela

    2017-09-02

    Wireless sensor networks are being increasingly used in several application areas, particularly to collect data and monitor physical processes. Non-functional requirements, like reliability, security or availability, are often important and must be accounted for in the application development. For that purpose, there is a large body of knowledge on dependability techniques for distributed systems, which provide a good basis to understand how to satisfy these non-functional requirements of WSN-based monitoring applications. Given the data-centric nature of monitoring applications, it is of particular importance to ensure that data are reliable or, more generically, that they have the necessary quality. In this survey, we look into the problem of ensuring the desired quality of data for dependable monitoring using WSNs. We take a dependability-oriented perspective, reviewing the possible impairments to dependability and the prominent existing solutions to solve or mitigate these impairments. Despite the variety of components that may form a WSN-based monitoring system, we give particular attention to understanding which faults can affect sensors, how they can affect the quality of the information and how this quality can be improved and quantified.

  10. An expert system/ion trap mass spectrometry approach for life support systems monitoring

    NASA Technical Reports Server (NTRS)

    Palmer, Peter T.; Wong, Carla M.; Yost, Richard A.; Johnson, Jodie V.; Yates, Nathan A.; Story, Michael

    1992-01-01

    Efforts to develop sensor and control system technology to monitor air quality for life support have resulted in the development and preliminary testing of a concept based on expert systems and ion trap mass spectrometry (ITMS). An ITMS instrument provides the capability to identify and quantitate a large number of suspected contaminants at trace levels through the use of a variety of multidimensional experiments. An expert system provides specialized knowledge for control, analysis, and decision making. The system is intended for real-time, on-line, autonomous monitoring of air quality. The key characteristics of the system, performance data and analytical capabilities of the ITMS instrument, the design and operation of the expert system, and results from preliminary testing of the system for trace contaminant monitoring are described.

  11. Monitoring Urban Quality of Life: The Porto Experience

    ERIC Educational Resources Information Center

    Santos, Luis Delfim; Martins, Isabel

    2007-01-01

    This paper describes the monitoring system of the urban quality of life developed by the Porto City Council, a new tool being used to support urban planning and management. The two components of this system--a quantitative approach based on statistical indicators and a qualitative analysis based on the citizens' perceptions of the conditions of…

  12. Environmental, political, and economic determinants of water quality monitoring in Europe

    NASA Astrophysics Data System (ADS)

    Beck, Lucas; Bernauer, Thomas; Kalbhenn, Anna

    2010-11-01

    Effective monitoring is essential for effective pollution control in national and international water systems. To what extent are countries' monitoring choices driven by environmental criteria, as they should be? And to what extent are they also influenced by other factors, such as political and economic conditions? To address these questions, we describe and explain the evolution of one of the most important international environmental monitoring networks in Europe, the one for water quality, in the time period 1965-2004. We develop a geographic information system that contains information on the location of several thousand active monitoring stations in Europe. Using multivariate statistics, we then examine whether and to what extent the spatial and temporal clustering of monitoring intensity is driven by environmental, political, and economic factors. The results show that monitoring intensity is higher in river basins exposed to greater environmental pressure. However, political and economic factors also play a strong role in monitoring decisions: democracy, income, and peer pressure are conducive to monitoring intensity, and monitoring intensity generally increases over time. Moreover, even though monitoring is more intense in international upstream-downstream settings, we observe only a weak bias toward more monitoring downstream of international borders. In contrast, negative effects of European Union (EU) membership and runup to the EU's Water Framework Directive are potential reasons for concern. Our results strongly suggest that international coordination and standardization of water quality monitoring should be intensified. It will be interesting to apply our analytical approach also to other national and international monitoring networks, for instance, the U.S. National Water-Quality Assessment Program or the European Monitoring and Evaluation Program for air pollution.

  13. Monitoring systems for community water supplies

    NASA Technical Reports Server (NTRS)

    Taylor, R. E.; Brooks, R. R.; Jeffers, E. L.; Linton, A. T.; Poel, G. D.

    1978-01-01

    Water monitoring system includes equipment and techniques for waste water sampling sensors for determining levels of microorganisms, oxygen, chlorine, and many other important parameters. System includes data acquisition and display system that allows computation of water quality information for real time display.

  14. Recent Advances in Point-of-Access Water Quality Monitoring

    NASA Astrophysics Data System (ADS)

    Korostynska, O.; Arshak, K.; Velusamy, V.; Arshak, A.; Vaseashta, Ashok

    Clean water is one of our most valuable natural resources. In addition to providing safe drinking water it assures functional ecosystems that support fisheries and recreation. Human population growth and its associated increased demands on water pose risks to maintaining acceptable water quality. It is vital to assess source waters and the aquatic systems that receive inputs from industrial waste and sewage treatment plants, storm water systems, and runoff from urban and agricultural lands. Rapid and confident assessments of aquatic resources form the basis for sound environmental management. Current methods engaged in tracing the presence of various bacteria in water employ bulky laboratory equipment and are time consuming. Thus, real-time water quality monitoring is essential for National and International Health and Safety. Environmental water monitoring includes measurements of physical characteristics (e.g. pH, temperature, conductivity), chemical parameters (e.g. oxygen, alkalinity, nitrogen and phosphorus compounds), and abundance of certain biological taxa. Monitoring could also include assays of biological activity such as alkaline phosphatase, tests for toxins such as microcystins and direct measurements of pollutants such as heavy metals or hydrocarbons. Real time detection can significantly reduce the level of damage and also the cost to remedy the problem. This paper presents overview of state-of-the-art methods and devices used for point-of-access water quality monitoring and suggest further developments in this area.

  15. Spectral Band Characterization for Hyperspectral Monitoring of Water Quality

    NASA Technical Reports Server (NTRS)

    Vermillion, Stephanie C.; Raqueno, Rolando; Simmons, Rulon

    2001-01-01

    A method for selecting the set of spectral characteristics that provides the smallest increase in prediction error is of interest to those using hyperspectral imaging (HSI) to monitor water quality. The spectral characteristics of interest to these applications are spectral bandwidth and location. Three water quality constituents of interest that are detectable via remote sensing are chlorophyll (CHL), total suspended solids (TSS), and colored dissolved organic matter (CDOM). Hyperspectral data provides a rich source of information regarding the content and composition of these materials, but often provides more data than an analyst can manage. This study addresses the spectral characteristics need for water quality monitoring for two reasons. First, determination of the greatest contribution of these spectral characteristics would greatly improve computational ease and efficiency. Second, understanding the spectral capabilities of different spectral resolutions and specific regions is an essential part of future system development and characterization. As new systems are developed and tested, water quality managers will be asked to determine sensor specifications that provide the most accurate and efficient water quality measurements. We address these issues using data from the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) and a set of models to predict constituent concentrations.

  16. A proposed ground-water quality monitoring network for Idaho

    USGS Publications Warehouse

    Whitehead, R.L.; Parliman, D.J.

    1979-01-01

    A ground water quality monitoring network is proposed for Idaho. The network comprises 565 sites, 8 of which will require construction of new wells. Frequencies of sampling at the different sites are assigned at quarterly, semiannual, annual, and 5 years. Selected characteristics of the water will be monitored by both laboratory- and field-analysis methods. The network is designed to: (1) Enable water managers to keep abreast of the general quality of the State 's ground water, and (2) serve as a warning system for undesirable changes in ground-water quality. Data were compiled for hydrogeologic conditions, ground-water quality, cultural elements, and pollution sources. A ' hydrologic unit priority index ' is used to rank 84 hydrologic units (river basins or segments of river basins) of the State for monitoring according to pollution potential. Emphasis for selection of monitoring sites is placed on the 15 highest ranked units. The potential for pollution is greatest in areas of privately owned agricultural land. Other areas of pollution potential are residential development, mining and related processes, and hazardous waste disposal. Data are given for laboratory and field analyses, number of site visits, manpower, subsistence, and mileage, from which costs for implementing the network can be estimated. Suggestions are made for data storage and retrieval and for reporting changes in water quality. (Kosco-USGS)

  17. 40 CFR 52.346 - Air quality monitoring requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Air quality monitoring requirements. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.346 Air quality monitoring... VIII Administrator, the State submitted a revised Air Quality Monitoring State Implementation Plan. The...

  18. 40 CFR 52.346 - Air quality monitoring requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Air quality monitoring requirements. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.346 Air quality monitoring... VIII Administrator, the State submitted a revised Air Quality Monitoring State Implementation Plan. The...

  19. 40 CFR 52.346 - Air quality monitoring requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Air quality monitoring requirements. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.346 Air quality monitoring... VIII Administrator, the State submitted a revised Air Quality Monitoring State Implementation Plan. The...

  20. 40 CFR 52.346 - Air quality monitoring requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Air quality monitoring requirements. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.346 Air quality monitoring... VIII Administrator, the State submitted a revised Air Quality Monitoring State Implementation Plan. The...

  1. 40 CFR 52.346 - Air quality monitoring requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Air quality monitoring requirements. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.346 Air quality monitoring... VIII Administrator, the State submitted a revised Air Quality Monitoring State Implementation Plan. The...

  2. Involvement of stakeholders in the water quality monitoring and surveillance system: The case of Mzingwane Catchment, Zimbabwe

    NASA Astrophysics Data System (ADS)

    Nare, Lerato; Love, David; Hoko, Zvikomborero

    of water is polluted, such as boiling water for human consumption, laundry and bathing, or abandoning a water source in extreme cases. Stakeholder participation and ownership of resources needs to be encouraged through participatory planning, and integration between the three government departments (water, environment and health). Local knowledge systems could be integrated into the formal water quality monitoring systems, in order to complement the conventional monitoring networks.

  3. Laser Welding Process Monitoring Systems: Advanced Signal Analysis for Quality Assurance

    NASA Astrophysics Data System (ADS)

    D'Angelo, Giuseppe

    Laser material processing today is widely used in industry. Especially laser welding became one of the key-technologies, e. g., for the automotive sector. This is due to the improvement and development of new laser sources and the increasing knowledge gained at countless scientific research projects. Nevertheless, it is still not possible to use the full potential of this technology. Therefore, the introduction and application of quality-assuring systems is required. For a long time, the statement "the best sensor is no sensor" was often heard. Today, a change of paradigm can be observed. On the one hand, ISO 9000 and other by law enforced regulations have led to the understanding that quality monitoring is an essential tool in modern manufacturing and necessary in order to keep production results in deterministic boundaries. On the other hand, rising quality requirements not only set higher and higher requirements for the process technology but also demand qualityassurance measures which ensure the reliable recognition of process faults. As a result, there is a need for reliable online detection and correction of welding faults by means of an in-process monitoring. The chapter describes an advanced signals analysis technique to extract information from signals detected, during the laser welding process, by optical sensors. The technique is based on the method of reassignment which was first applied to the spectrogram by Kodera, Gendrin and de Villedary22,23 and later generalized to any bilinear time-frequency representation by Auger and Flandrin.24 Key to the method is a nonlinear convolution where the value of the convolution is not placed at the center of the convolution kernel but rather reassigned to the center of mass of the function within the kernel. The resulting reassigned representation yields significantly improved components localization. We compare the proposed time-frequency distributions by analyzing signals detected during the laser welding of

  4. 40 CFR 130.4 - Water quality monitoring.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 22 2014-07-01 2013-07-01 true Water quality monitoring. 130.4 Section 130.4 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS WATER QUALITY PLANNING AND MANAGEMENT § 130.4 Water quality monitoring. (a) In accordance with section 106(e)(1...

  5. 40 CFR 130.4 - Water quality monitoring.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 23 2012-07-01 2012-07-01 false Water quality monitoring. 130.4 Section 130.4 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS WATER QUALITY PLANNING AND MANAGEMENT § 130.4 Water quality monitoring. (a) In accordance with section 106(e)(1...

  6. 40 CFR 130.4 - Water quality monitoring.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 23 2013-07-01 2013-07-01 false Water quality monitoring. 130.4 Section 130.4 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS WATER QUALITY PLANNING AND MANAGEMENT § 130.4 Water quality monitoring. (a) In accordance with section 106(e)(1...

  7. Letter Report Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Tonopah Airport, Nye County, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. Engelbrecht; I. Kavouras; D. Campbell

    2009-04-02

    The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Tonopah Airport, Beatty, Rachel, Caliente, Pahranagat NWR, Crater Flat, and the Tonopah Airport, and at four sites on the NTS (Engelbrecht et al.,more » 2007a-d). The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data, on completion of the site's sampling program.« less

  8. Letter Report: Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Tonopah Airport, Nye County, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. Engelbrecht; I. Kavouras; D Campbell

    2008-08-01

    The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Tonopah Airport, Beatty, Rachel, Caliente, Pahranagat NWR, Crater Flat, and the Tonopah Airport, and at four sites on the NTS (Engelbrecht et al.,more » 2007a-d). The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data, on completion of the site's sampling program.« less

  9. Coma Patient Monitoring System Using Image Processing

    NASA Astrophysics Data System (ADS)

    Sankalp, Meenu

    2011-12-01

    COMA PATIENT MONITORING SYSTEM provides high quality healthcare services in the near future. To provide more convenient and comprehensive medical monitoring in big hospitals since it is tough job for medical personnel to monitor each patient for 24 hours.. The latest development in patient monitoring system can be used in Intensive Care Unit (ICU), Critical Care Unit (CCU), and Emergency Rooms of hospital. During treatment, the patient monitor is continuously monitoring the coma patient to transmit the important information. Also in the emergency cases, doctor are able to monitor patient condition efficiently to reduce time consumption, thus it provides more effective healthcare system. So due to importance of patient monitoring system, the continuous monitoring of the coma patient can be simplified. This paper investigates about the effects seen in the patient using "Coma Patient Monitoring System" which is a very advanced product related to physical changes in body movement of the patient and gives Warning in form of alarm and display on the LCD in less than one second time. It also passes a sms to a person sitting at the distant place if there exists any movement in any body part of the patient. The model for the system uses Keil software for the software implementation of the developed system.

  10. Quality-control issues on high-resolution diagnostic monitors.

    PubMed

    Parr, L F; Anderson, A L; Glennon, B K; Fetherston, P

    2001-06-01

    Previous literature indicates a need for more data collection in the area of quality control of high-resolution diagnostic monitors. Throughout acceptance testing, which began in June 2000, stability of monitor calibration was analyzed. Although image quality on all monitors was found to be acceptable upon initial acceptance testing using VeriLUM software by Image Smiths, Inc (Germantown, MD), it was determined to be unacceptable during the clinical phase of acceptance testing. High-resolution monitors were evaluated for quality assurance on a weekly basis from installation through acceptance testing and beyond. During clinical utilization determination (CUD), monitor calibration was identified as a problem and the manufacturer returned and recalibrated all workstations. From that time through final acceptance testing, high-resolution monitor calibration and monitor failure rate remained a problem. The monitor vendor then returned to the site to address these areas. Monitor defocus was still noticeable and calibration checks were increased to three times per week. White and black level drift on medium-resolution monitors had been attributed to raster size settings. Measurements of white and black level at several different size settings were taken to determine the effect of size on white and black level settings. Black level remained steady with size change. White level appeared to increase by 2.0 cd/m2 for every 0.1 inches decrease in horizontal raster size. This was determined not to be the cause of the observed brightness drift. Frequency of calibration/testing is an issue in a clinical environment. The increased frequency required at our site cannot be sustained. The medical physics division cannot provide dedicated personnel to conduct the quality-assurance testing on all monitors at this interval due to other physics commitments throughout the hospital. Monitor access is also an issue due to radiologists' need to read images. Some workstations are in use 7 AM

  11. 40 CFR 141.87 - Monitoring requirements for water quality parameters.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... (c) Monitoring after installation of corrosion control. Any large system which installs optimal corrosion control treatment pursuant to § 141.81(d)(4) shall measure the water quality parameters at the...)(i). Any small or medium-size system which installs optimal corrosion control treatment shall conduct...

  12. 40 CFR 141.87 - Monitoring requirements for water quality parameters.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... (c) Monitoring after installation of corrosion control. Any large system which installs optimal corrosion control treatment pursuant to § 141.81(d)(4) shall measure the water quality parameters at the...)(i). Any small or medium-size system which installs optimal corrosion control treatment shall conduct...

  13. 40 CFR 141.87 - Monitoring requirements for water quality parameters.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... (c) Monitoring after installation of corrosion control. Any large system which installs optimal corrosion control treatment pursuant to § 141.81(d)(4) shall measure the water quality parameters at the...)(i). Any small or medium-size system which installs optimal corrosion control treatment shall conduct...

  14. 40 CFR 141.87 - Monitoring requirements for water quality parameters.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... (c) Monitoring after installation of corrosion control. Any large system which installs optimal corrosion control treatment pursuant to § 141.81(d)(4) shall measure the water quality parameters at the...)(i). Any small or medium-size system which installs optimal corrosion control treatment shall conduct...

  15. 40 CFR 141.87 - Monitoring requirements for water quality parameters.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... (c) Monitoring after installation of corrosion control. Any large system which installs optimal corrosion control treatment pursuant to § 141.81(d)(4) shall measure the water quality parameters at the...)(i). Any small or medium-size system which installs optimal corrosion control treatment shall conduct...

  16. Air Quality Monitoring and Sensor Technologies

    EPA Pesticide Factsheets

    EPA scientist Ron Williams presented on the features, examination, application, examples, and data quality of continuous monitoring study designs at EPA's Community Air Monitoring Training in July 2015.

  17. Integration of remote sensing and geographic information systems for Great Lakes water quality monitoring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lathrop, R.G. Jr.

    1988-01-01

    The utility of three operational satellite remote sensing systems, namely, the Landsat Thematic Mapper (TM), the SPOT High Resolution Visible (HRV) sensors and the NOAA Advanced Very High Resolution Radiometer (AVHRR), were evaluated as a means of estimating water quality and surface temperature. Empirical calibration through linear regression techniques was used to relate near-simultaneously acquired satellite radiance/reflectance data and water quality observations obtained in Green Bay and the nearshore waters of Lake Michigan. Four dates of TM and one date each of SPOT and AVHRR imagery/surface reference data were acquired and analyzed. Highly significant relationships were identified between the TMmore » and SPOT data and secchi disk depth, nephelometric turbidity, chlorophyll a, total suspended solids (TSS), absorbance, and surface temperature (TM only). The AVHRR data were not analyzed independently but were used for comparison with the TM data. Calibrated water quality image maps were input to a PC-based raster GIS package, EPPL7. Pattern interpretation and spatial analysis techniques were used to document the circulation dynamics and model mixing processes in Green Bay. A GIS facilitates the retrieval, query and spatial analysis of mapped information and provides the framework for an integrated operational monitoring system for the Great Lakes.« less

  18. 40 CFR 51.190 - Ambient air quality monitoring requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Ambient air quality monitoring... PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Ambient Air Quality Surveillance § 51.190 Ambient air quality monitoring requirements. The requirements for monitoring ambient air...

  19. 40 CFR 51.190 - Ambient air quality monitoring requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 2 2013-07-01 2013-07-01 false Ambient air quality monitoring... PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Ambient Air Quality Surveillance § 51.190 Ambient air quality monitoring requirements. The requirements for monitoring ambient air...

  20. 40 CFR 51.190 - Ambient air quality monitoring requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 2 2014-07-01 2014-07-01 false Ambient air quality monitoring... PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Ambient Air Quality Surveillance § 51.190 Ambient air quality monitoring requirements. The requirements for monitoring ambient air...

  1. 40 CFR 51.190 - Ambient air quality monitoring requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 2 2011-07-01 2011-07-01 false Ambient air quality monitoring... PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Ambient Air Quality Surveillance § 51.190 Ambient air quality monitoring requirements. The requirements for monitoring ambient air...

  2. 40 CFR 51.190 - Ambient air quality monitoring requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 2 2012-07-01 2012-07-01 false Ambient air quality monitoring... PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Ambient Air Quality Surveillance § 51.190 Ambient air quality monitoring requirements. The requirements for monitoring ambient air...

  3. Water quality success stories: Integrated assessments from the IOOS regional associations and national water quality monitoring network

    USGS Publications Warehouse

    Ragsdale, Rob; Vowinkel, Eric; Porter, Dwayne; Hamilton, Pixie; Morrison, Ru; Kohut, Josh; Connell, Bob; Kelsey, Heath; Trowbridge, Phil

    2011-01-01

    The Integrated Ocean Observing System (IOOS®) Regional Associations and Interagency Partners hosted a water quality workshop in January 2010 to discuss issues of nutrient enrichment and dissolved oxygen depletion (hypoxia), harmful algal blooms (HABs), and beach water quality. In 2007, the National Water Quality Monitoring Council piloted demonstration projects as part of the National Water Quality Monitoring Network (Network) for U.S. Coastal Waters and their Tributaries in three IOOS Regional Associations, and these projects are ongoing. Examples of integrated science-based solutions to water quality issues of major concern from the IOOS regions and Network demonstration projects are explored in this article. These examples illustrate instances where management decisions have benefited from decision-support tools that make use of interoperable data. Gaps, challenges, and outcomes are identified, and a proposal is made for future work toward a multiregional water quality project for beach water quality.

  4. Measurement results obtained from air quality monitoring system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Turzanski, P.K.; Beres, R.

    1995-12-31

    An automatic system of air pollution monitoring operates in Cracow since 1991. The organization, assembling and start-up of the network is a result of joint efforts of the US Environmental Protection Agency and the Cracow environmental protection service. At present the automatic monitoring network is operated by the Provincial Inspection of Environmental Protection. There are in total seven stationary stations situated in Cracow to measure air pollution. These stations are supported continuously by one semi-mobile (transportable) station. It allows to modify periodically the area under investigation and therefore the 3-dimensional picture of creation and distribution of air pollutants within Cracowmore » area could be more intelligible.« less

  5. A Two-Year Water Quality Monitoring Curriculum.

    ERIC Educational Resources Information Center

    Glazer, Richard B.; And Others

    The Environmental Protection Agency developed this curriculum to train technicians to monitor water quality. Graduates of the program should be able to monitor municipal, industrial, and commercial discharges; test drinking water for purity; and determine quality of aquatic environments. The program includes algebra, communication skills, biology,…

  6. SAMIRA - SAtellite based Monitoring Initiative for Regional Air quality

    NASA Astrophysics Data System (ADS)

    Schneider, Philipp; Stebel, Kerstin; Ajtai, Nicolae; Diamandi, Andrei; Horalek, Jan; Nicolae, Doina; Stachlewska, Iwona; Zehner, Claus

    2016-04-01

    Czech Republic, and the Gorj County in Romania. All data products shall undergo a quality control, i.e. robust and independent validation. The SAMIRA consortium will further work towards a pre-operational system for improved PM10 forecasts using observational (in situ and satellite) data assimilation. SAMIRA aims to maximize project benefits by liaison with national and regional environmental protection agencies and health institutions, as well as related ESA and European initiatives such as the Copernicus Atmospheric Monitoring Services (CAMS).

  7. Robust GPS autonomous signal quality monitoring

    NASA Astrophysics Data System (ADS)

    Ndili, Awele Nnaemeka

    The Global Positioning System (GPS), introduced by the U.S. Department of Defense in 1973, provides unprecedented world-wide navigation capabilities through a constellation of 24 satellites in global orbit, each emitting a low-power radio-frequency signal for ranging. GPS receivers track these transmitted signals, computing position to within 30 meters from range measurements made to four satellites. GPS has a wide range of applications, including aircraft, marine and land vehicle navigation. Each application places demands on GPS for various levels of accuracy, integrity, system availability and continuity of service. Radio frequency interference (RFI), which results from natural sources such as TV/FM harmonics, radar or Mobile Satellite Systems (MSS), presents a challenge in the use of GPS, by posing a threat to the accuracy, integrity and availability of the GPS navigation solution. In order to use GPS for integrity-sensitive applications, it is therefore necessary to monitor the quality of the received signal, with the objective of promptly detecting the presence of RFI, and thus provide a timely warning of degradation of system accuracy. This presents a challenge, since the myriad kinds of RFI affect the GPS receiver in different ways. What is required then, is a robust method of detecting GPS accuracy degradation, which is effective regardless of the origin of the threat. This dissertation presents a new method of robust signal quality monitoring for GPS. Algorithms for receiver autonomous interference detection and integrity monitoring are demonstrated. Candidate test statistics are derived from fundamental receiver measurements of in-phase and quadrature correlation outputs, and the gain of the Active Gain Controller (AGC). Performance of selected test statistics are evaluated in the presence of RFI: broadband interference, pulsed and non-pulsed interference, coherent CW at different frequencies; and non-RFI: GPS signal fading due to physical blockage and

  8. Monitoring on The Quality and Quantity of DIY Rainwater Harvesting System

    NASA Astrophysics Data System (ADS)

    Kasmin, H.; Bakar, N. H.; Zubir, M. M.

    2016-07-01

    Rainwater harvesting is an alternative sources of water supply and can be used for potable and non-potable uses. It could helps to store treated rainwater for more beneficial use and also for flood mitigation. Sustainable approach for flooding problem reduction in urban areas is by slowing down the rate of surface runoff flows at source by providing more storage area/tank. In order to understand the performance of a rainwater harvesting system (RWH), a preliminary monitoring on a ‘do it yourself’ (DIY) RWH model with additional first -flush strategy for water quality treatment was done. The main concept behind first flush diversion is to prevent initial polluted rainwater from entering the storage tank. Based on seven rainfall events observed in Parit Raja, both quality and quantity of the rainfalls were analysed. For rainwater quality, the samples from first flush diverter and storage tank were taken to understand their performance based on pH, dissolved oxygen (DO), turbidity, total dissolved solid (TDS), total suspended solid (TSS), chemical oxygen demand (COD) and biochemical oxygen demand (BOD) parameters. While for rainwater quantity, hydrograph analysis were done based on the performance of total rainfall and runoff, peak flow of rainfall and runoff; and delayed time parameters. Based on Interim National Water Quality Standard (INWQS) and National Drinking Water Quality Standard (NDWQS), first flush diverter apparently helps on water quality improvement in storage tanks when pH, DO, TDS, TSS and turbidity were classified as Class I (INWQS) and is allowable for drinking; but BOD and COD parameters were classified as Class III (INWQS). Hence, it has potential to be used as potable usage but will need extensive treatment to reduce its poor microbial quality. Based on the maximum observed rainfall event which had total volume of 3195.5 liter, had peakflow reduction from 0.00071 m3/s to 0.00034 m3/s and delayed runoff between 5 and 10 minutes after rainfall

  9. Design and implementation air quality monitoring robot

    NASA Astrophysics Data System (ADS)

    Chen, Yuanhua; Li, Jie; Qi, Chunxue

    2017-01-01

    Robot applied in environmental protection can break through the limitations in working environment, scope and mode of the existing environmental monitoring and pollution abatement equipments, which undertake the innovation and improvement in the basin, atmosphere, emergency and pollution treatment facilities. Actually, the relevant technology is backward with limited research and investment. Though the device companies have achieved some results in the study on the water quality monitoring, pipeline monitoring and sewage disposal, this technological progress on the whole is still much slow, and the mature product has not been formed. As a result, the market urges a demand of a new type of device which is more suitable for environmental protection on the basis of robot successfully applied in other fields. This paper designs and realizes a tracked mobile robot of air quality monitoring, which can be used to monitor air quality for the pollution accident in industrial parks and regular management.

  10. Assessment of water quality monitoring for the optimal sensor placement in lake Yahuarcocha using pattern recognition techniques and geographical information systems.

    PubMed

    Jácome, Gabriel; Valarezo, Carla; Yoo, Changkyoo

    2018-03-30

    Pollution and the eutrophication process are increasing in lake Yahuarcocha and constant water quality monitoring is essential for a better understanding of the patterns occurring in this ecosystem. In this study, key sensor locations were determined using spatial and temporal analyses combined with geographical information systems (GIS) to assess the influence of weather features, anthropogenic activities, and other non-point pollution sources. A water quality monitoring network was established to obtain data on 14 physicochemical and microbiological parameters at each of seven sample sites over a period of 13 months. A spatial and temporal statistical approach using pattern recognition techniques, such as cluster analysis (CA) and discriminant analysis (DA), was employed to classify and identify the most important water quality parameters in the lake. The original monitoring network was reduced to four optimal sensor locations based on a fuzzy overlay of the interpolations of concentration variations of the most important parameters.

  11. Spatial-temporal distortion metric for in-service quality monitoring of any digital video system

    NASA Astrophysics Data System (ADS)

    Wolf, Stephen; Pinson, Margaret H.

    1999-11-01

    Many organizations have focused on developing digital video quality metrics which produce results that accurately emulate subjective responses. However, to be widely applicable a metric must also work over a wide range of quality, and be useful for in-service quality monitoring. The Institute for Telecommunication Sciences (ITS) has developed spatial-temporal distortion metrics that meet all of these requirements. These objective metrics are described in detail and have a number of interesting properties, including utilization of (1) spatial activity filters which emphasize long edges on the order of 10 arc min while simultaneously performing large amounts of noise suppression, (2) the angular direction of the spatial gradient, (3) spatial-temporal compression factors of at least 384:1 (spatial compression of at least 64:1 and temporal compression of at least 6:1, and 4) simple perceptibility thresholds and spatial-temporal masking functions. Results are presented that compare the objective metric values with mean opinion scores from a wide range of subjective data bases spanning many different scenes, systems, bit-rates, and applications.

  12. Helmet-based physiological signal monitoring system.

    PubMed

    Kim, Youn Sung; Baek, Hyun Jae; Kim, Jung Soo; Lee, Haet Bit; Choi, Jong Min; Park, Kwang Suk

    2009-02-01

    A helmet-based system that was able to monitor the drowsiness of a soldier was developed. The helmet system monitored the electrocardiogram, electrooculogram and electroencephalogram (alpha waves) without constraints. Six dry electrodes were mounted at five locations on the helmet: both temporal sides, forehead region and upper and lower jaw strips. The electrodes were connected to an amplifier that transferred signals to a laptop computer via Bluetooth wireless communication. The system was validated by comparing the signal quality with conventional recording methods. Data were acquired from three healthy male volunteers for 12 min twice a day whilst they were sitting in a chair wearing the sensor-installed helmet. Experimental results showed that physiological signals for the helmet user were measured with acceptable quality without any intrusions on physical activities. The helmet system discriminated between the alert and drowsiness states by detecting blinking and heart rate variability (HRV) parameters extracted from ECG. Blinking duration and eye reopening time were increased during the sleepiness state compared to the alert state. Also, positive peak values of the sleepiness state were much higher, and the negative peaks were much lower than that of the alert state. The LF/HF ratio also decreased during drowsiness. This study shows the feasibility for using this helmet system: the subjects' health status and mental states could be monitored without constraints whilst they were working.

  13. Student satisfaction as an element of education quality monitoring in innovative higher education institution

    NASA Astrophysics Data System (ADS)

    Razinkina, Elena; Pankova, Ludmila; Trostinskaya, Irina; Pozdeeva, Elena; Evseeva, Lidiya; Tanova, Anna

    2018-03-01

    Topicality of the research is confirmed by increasing student involvement into the educational process, when not only the academic staff and administration participate in the improvement of higher education institution's activity, but also education customers - students. This adds a new dimension to the issue of monitoring education quality and student satisfaction with higher education. This issue echoes the ideas of M. Weber about the relationship between such components as cognitive motivation, personal development and student satisfaction with higher education. Besides, it is essential to focus on the approach of R. Barnet to defining the quality of education with the emphasis on a priority of development of an educational institution as the system that meets customers' needs. Monitoring student satisfaction with education quality has become an integral part of the educational process not only in a number of European universities, which have used this monitoring for decades, but also in Russian universities, which are interested in education quality improvement. Leading universities in Russia, including Peter the Great St. Petersburg Polytechnic University, are implementing policies targeted at increasing student satisfaction with higher education quality. Education quality monitoring as a key element in the system of providing feedback to students contributes greatly to this process.

  14. Event-Driven Messaging for Offline Data Quality Monitoring at ATLAS

    NASA Astrophysics Data System (ADS)

    Onyisi, Peter

    2015-12-01

    During LHC Run 1, the information flow through the offline data quality monitoring in ATLAS relied heavily on chains of processes polling each other's outputs for handshaking purposes. This resulted in a fragile architecture with many possible points of failure and an inability to monitor the overall state of the distributed system. We report on the status of a project undertaken during the LHC shutdown to replace the ad hoc synchronization methods with a uniform message queue system. This enables the use of standard protocols to connect processes on multiple hosts; reliable transmission of messages between possibly unreliable programs; easy monitoring of the information flow; and the removal of inefficient polling-based communication.

  15. Letter Report: Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Pahranagat National Wildlife Refuge, Lincoln County, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. Englebrecht; I. Kavouras; D. Campbell

    2008-08-01

    The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Pahranagat NWR, Beatty, Rachel, Caliente, Crater Flat, and Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d). The trailermore » is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data on completion of the site's sampling program.« less

  16. Letter Report Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Pahranagat National Wildlife Refuge, Lincoln County, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. Engelbrecht; I. Kavouras; D. Campbell

    2009-04-02

    The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Pahranagat NWR, Beatty, Rachel, Caliente, Crater Flat, and Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d). The trailermore » is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data on completion of the site's sampling program.« less

  17. Using business intelligence to monitor clinical quality metrics.

    PubMed

    Resetar, Ervina; Noirot, Laura A; Reichley, Richard M; Storey, Patricia; Skiles, Ann M; Traynor, Patrick; Dunagan, W Claiborne; Bailey, Thomas C

    2007-10-11

    BJC HealthCare (BJC) uses a number of industry standard indicators to monitor the quality of services provided by each of its hospitals. By establishing an enterprise data warehouse as a central repository of clinical quality information, BJC is able to monitor clinical quality performance in a timely manner and improve clinical outcomes.

  18. Monitoring Air Quality over China: Evaluation of the modeling system of the PANDA project

    NASA Astrophysics Data System (ADS)

    Bouarar, Idir; Katinka Petersen, Anna; Brasseur, Guy; Granier, Claire; Xie, Ying; Wang, Xuemei; Fan, Qi; Wang, Lili

    2015-04-01

    Air pollution has become a pressing problem in Asia and specifically in China due to rapid increase in anthropogenic emissions related to growth of China's economic activity and increasing demand for energy in the past decade. Observed levels of particulate matter and ozone regularly exceed World Health Organization (WHO) air quality guidelines in many parts of the country leading to increased risk of respiratory illnesses and other health problems. The EU-funded project PANDA aims to establish a team of European and Chinese scientists to monitor air pollution over China and elaborate air quality indicators in support of European and Chinese policies. PANDA combines state-of-the-art air pollution modeling with space and surface observations of chemical species to improve methods for monitoring air quality. The modeling system of the PANDA project follows a downscaling approach: global models such as MOZART and MACC system provide initial and boundary conditions to regional WRF-Chem and EMEP simulations over East Asia. WRF-Chem simulations at higher resolution (e.g. 20km) are then performed over a smaller domain covering East China and initial and boundary conditions from this run are used to perform simulations at a finer resolution (e.g. 5km) over specific megacities like Shanghai. Here we present results of model simulations for January and July 2010 performed during the first year of the project. We show an intercomparison of the global (MACC, EMEP) and regional (WRF-Chem) simulations and a comprehensive evaluation with satellite measurements (NO2, CO) and in-situ data (O3, CO, NOx, PM10 and PM2.5) at several surface stations. Using the WRF-Chem model, we demonstrate that model performance is influenced not only by the resolution (e.g. 60km, 20km) but also the emission inventories used (MACCity, HTAPv2), their resolution and diurnal variation, and the choice of initial and boundary conditions (e.g. MOZART, MACC analysis).

  19. Development of an autonomous, wireless pH and temperature sensing system for monitoring pig meat quality.

    PubMed

    Frisby, June; Raftery, Declan; Kerry, Joe P; Diamond, Dermot

    2005-06-01

    This paper focuses on the development of a unique wireless pH and temperature monitoring system to assess pig meat quality. Pale, soft and exudative (PSE) pig meat continues to be a major problem in the pig meat industry today. The PSE condition in pork is related to a number of factors including genetics, pre-slaughter stress and insufficient chilling of pig carcasses, which cause a rapid rate of glycolysis post-mortem (<1h). As a result the pH drops to low levels while the muscle temperature is still high. A wireless dual channel system that monitors pH and temperature simultaneously has been developed to provide pH and temperature data of the carcass during the first 24h after slaughter. We have demonstrated that this approach can distinguish in real time, pH and temperature profiles that are 'non-normal', and identify carcasses that are PSE positive quickly and easily.

  20. A network for continuous monitoring of water quality in the Sabine River basin, Texas and Louisiana

    USGS Publications Warehouse

    Blakey, J.F.; Skinner, P.W.

    1973-01-01

    Level I operations at a proposed site would monitor current and potential problems, water-quality changes in subreaches of streams, and water-quality trends in time and place. Level II operations would monitor current or potential problems only. An optimum system would require Level I operations at all nine stations. A minimum system would require Level II operations at most of the stations.

  1. Baby-MONITOR: A Composite Indicator of NICU Quality

    PubMed Central

    Kowalkowski, Marc A.; Zupancic, John A. F.; Pietz, Kenneth; Richardson, Peter; Draper, David; Hysong, Sylvia J.; Thomas, Eric J.; Petersen, Laura A.; Gould, Jeffrey B.

    2014-01-01

    BACKGROUND AND OBJECTIVES: NICUs vary in the quality of care delivered to very low birth weight (VLBW) infants. NICU performance on 1 measure of quality only modestly predicts performance on others. Composite measurement of quality of care delivery may provide a more comprehensive assessment of quality. The objective of our study was to develop a robust composite indicator of quality of NICU care provided to VLBW infants that accurately discriminates performance among NICUs. METHODS: We developed a composite indicator, Baby-MONITOR, based on 9 measures of quality chosen by a panel of experts. Measures were standardized, equally weighted, and averaged. We used the California Perinatal Quality Care Collaborative database to perform across-sectional analysis of care given to VLBW infants between 2004 and 2010. Performance on the Baby-MONITOR is not an absolute marker of quality but indicates overall performance relative to that of the other NICUs. We used sensitivity analyses to assess the robustness of the composite indicator, by varying assumptions and methods. RESULTS: Our sample included 9023 VLBW infants in 22 California regional NICUs. We found significant variations within and between NICUs on measured components of the Baby-MONITOR. Risk-adjusted composite scores discriminated performance among this sample of NICUs. Sensitivity analysis that included different approaches to normalization, weighting, and aggregation of individual measures showed the Baby-MONITOR to be robust (r = 0.89–0.99). CONCLUSIONS: The Baby-MONITOR may be a useful tool to comprehensively assess the quality of care delivered by NICUs. PMID:24918221

  2. Automated recognition system for power quality disturbances

    NASA Astrophysics Data System (ADS)

    Abdelgalil, Tarek

    The application of deregulation policies in electric power systems has resulted in the necessity to quantify the quality of electric power. This fact highlights the need for a new monitoring strategy which is capable of tracking, detecting, classifying power quality disturbances, and then identifying the source of the disturbance. The objective of this work is to design an efficient and reliable power quality monitoring strategy that uses the advances in signal processing and pattern recognition to overcome the deficiencies that exist in power quality monitoring devices. The purposed monitoring strategy has two stages. The first stage is to detect, track, and classify any power quality violation by the use of on-line measurements. In the second stage, the source of the classified power quality disturbance must be identified. In the first stage, an adaptive linear combiner is used to detect power quality disturbances. Then, the Teager Energy Operator and Hilbert Transform are utilized for power quality event tracking. After the Fourier, Wavelet, and Walsh Transforms are employed for the feature extraction, two approaches are then exploited to classify the different power quality disturbances. The first approach depends on comparing the disturbance to be classified with a stored set of signatures for different power quality disturbances. The comparison is developed by using Hidden Markov Models and Dynamic Time Warping. The second approach depends on employing an inductive inference to generate the classification rules directly from the data. In the second stage of the new monitoring strategy, only the problem of identifying the location of the switched capacitor which initiates the transients is investigated. The Total Least Square-Estimation of Signal Parameters via Rotational Invariance Technique is adopted to estimate the amplitudes and frequencies of the various modes contained in the voltage signal measured at the facility entrance. After extracting the

  3. Successful water quality monitoring: The right combination of intent, measurement, interpretation, and a cooperating ecosystem

    USGS Publications Warehouse

    Soballe, D.M.

    1998-01-01

    Water quality monitoring is invaluable to ensure compliance with regulations, detect trends or patterns, and advance ecological understanding. However, monitoring typically measures only a few characteristics in a small fraction of a large and complex system, and thus the information contained in monitoring data depends upon which features of the ecosystem are actually captured by the measurements. Difficulties arise when these data contain something other than intended, but this can be minimized if the purpose of the sampling is clear, and the sampling design, measurements, and data interpretations are all compatible with this purpose. The monitoring program and data interpretation must also be properly matched to the structure and functioning of the system. Obtaining this match is sometimes an iterative process that demands a close link between research and monitoring. This paper focuses on water quality monitoring that is intended to track trends in aquatic resources and advance ecological understanding. It includes examples from three monitoring programs and a simulation exercise that illustrate problems that arise when the information content of monitoring data differs from expectation. The examples show (1) how inconsistencies among, or lack of information about, the basic elements of a monitoring program (intent, design, measurement, interpretation, and the monitored system) can produce a systematic difference (bias) between monitoring measurements and sampling intent or interpretation, and (2) that bias is not just a statistical consideration, but an insidious problem that can undermine the scientific integrity of a monitoring program. Some general suggestions are provided and hopefully these examples will help those engaged in water quality monitoring to enhance and protect the value of their monitoring investment.

  4. Guidelines and standard procedures for continuous water-quality monitors: Station operation, record computation, and data reporting

    USGS Publications Warehouse

    Wagner, Richard J.; Boulger, Robert W.; Oblinger, Carolyn J.; Smith, Brett A.

    2006-01-01

    The U.S. Geological Survey uses continuous water-quality monitors to assess the quality of the Nation's surface water. A common monitoring-system configuration for water-quality data collection is the four-parameter monitoring system, which collects temperature, specific conductance, dissolved oxygen, and pH data. Such systems also can be configured to measure other properties, such as turbidity or fluorescence. Data from sensors can be used in conjunction with chemical analyses of samples to estimate chemical loads. The sensors that are used to measure water-quality field parameters require careful field observation, cleaning, and calibration procedures, as well as thorough procedures for the computation and publication of final records. This report provides guidelines for site- and monitor-selection considerations; sensor inspection and calibration methods; field procedures; data evaluation, correction, and computation; and record-review and data-reporting processes, which supersede the guidelines presented previously in U.S. Geological Survey Water-Resources Investigations Report WRIR 00-4252. These procedures have evolved over the past three decades, and the process continues to evolve with newer technologies.

  5. [The design and experiment of multi-parameter water quality monitoring microsystem based on MOEMS microspectrometer].

    PubMed

    Wei, Kang-Lin; Wen, Zhi-Yu; Guo, Jian; Chen, Song-Bo

    2012-07-01

    Aiming at the monitoring and protecting of water resource environment, a multi-parameter water quality monitoring microsystem based on microspectrometer was put forward in the present paper. The microsystem is mainly composed of MOEMS microspectrometer, flow paths system and embedded measuring & controlling system. It has the functions of self-injecting samples and detection regents, automatic constant temperature, self -stirring, self- cleaning and samples' spectrum detection. The principle prototype machine of the microsystem was developed, and its structure principle was introduced in the paper. Through experiment research, it was proved that the principle prototype machine can rapidly detect quite a few water quality parameters and can meet the demands of on-line water quality monitoring, moreover, the principle prototype machine has strong function expansibility.

  6. U.S. Geological Survey quality-assurance plan for continuous water-quality monitoring in Kansas, 2014

    USGS Publications Warehouse

    Bennett, Trudy J.; Graham, Jennifer L.; Foster, Guy M.; Stone, Mandy L.; Juracek, Kyle E.; Rasmussen, Teresa J.; Putnam, James E.

    2014-01-01

    A quality-assurance plan for use in conducting continuous water-quality monitoring activities has been developed for the Kansas Water Science Center in accordance with guidelines set forth by the U.S. Geological Survey. This quality-assurance plan documents the standards, policies, and procedures used by the U.S. Geological Survey in Kansas for activities related to the collection, processing, storage, analysis, and release of continuous water-quality monitoring data. The policies and procedures that are documented in this quality-assurance plan for continuous water-quality monitoring activities complement quality-assurance plans for surface-water and groundwater activities in Kansas.

  7. The water-quality monitoring program for the Baltimore reservoir system, 1981-2007—Description, review and evaluation, and framework integration for enhanced monitoring

    USGS Publications Warehouse

    Koterba, Michael T.; Waldron, Marcus C.; Kraus, Tamara E.C.

    2011-01-01

    The City of Baltimore, Maryland, and parts of five surrounding counties obtain their water from Loch Raven and Liberty Reservoirs. A third reservoir, Prettyboy, is used to resupply Loch Raven Reservoir. Management of the watershed conditions for each reservoir is a shared responsibility by agreement among City, County, and State jurisdictions. The most recent (2005) Baltimore Reservoir Watershed Management Agreement (RWMA) called for continued and improved water-quality monitoring in the reservoirs and selected watershed tributaries. The U.S. Geological Survey (USGS) conducted a retrospective review of the effectiveness of monitoring data obtained and analyzed by the RWMA jurisdictions from 1981 through 2007 to help identify possible improvements in the monitoring program to address RWMA water-quality concerns. Long-term water-quality concerns include eutrophication and sedimentation in the reservoirs, and elevated concentrations of (a) nutrients (nitrogen and phosphorus) being transported from the major tributaries to the reservoirs, (b) iron and manganese released from reservoir bed sediments during periods of deep-water anoxia, (c) mercury in higher trophic order game fish in the reservoirs, and (d) bacteria in selected reservoir watershed tributaries. Emerging concerns include elevated concentrations of sodium, chloride, and disinfection by-products (DBPs) in the drinking water from both supply reservoirs. Climate change and variability also could be emerging concerns, affecting seasonal patterns, annual trends, and drought occurrence, which historically have led to declines in reservoir water quality. Monitoring data increasingly have been used to support the development of water-quality models. The most recent (2006) modeling helped establish an annual sediment Total Maximum Daily Load to Loch Raven Reservoir, and instantaneous and 30-day moving average water-quality endpoints for chlorophyll-a (chl-a) and dissolved oxygen (DO) in Loch Raven and Prettyboy

  8. Development of a Personal Integrated Environmental Monitoring System

    PubMed Central

    Wong, Man Sing; Yip, Tsan Pong; Mok, Esmond

    2014-01-01

    Environmental pollution in the urban areas of Hong Kong has become a serious public issue but most urban inhabitants have no means of judging their own living environment in terms of dangerous threshold and overall livability. Currently there exist many low-cost sensors such as ultra-violet, temperature and air quality sensors that provide reasonably accurate data quality. In this paper, the development and evaluation of Integrated Environmental Monitoring System (IEMS) are illustrated. This system consists of three components: (i) position determination and sensor data collection for real-time geospatial-based environmental monitoring; (ii) on-site data communication and visualization with the aid of an Android-based application; and (iii) data analysis on a web server. This system has shown to be working well during field tests in a bus journey and a construction site. It provides an effective service platform for collecting environmental data in near real-time, and raises the public awareness of environmental quality in micro-environments. PMID:25420154

  9. An Unmanned Aerial Vehicle Cluster Network Cruise System for Monitor

    NASA Astrophysics Data System (ADS)

    Jiang, Jirong; Tao, Jinpeng; Xin, Guipeng

    2018-06-01

    The existing maritime cruising system mainly uses manned motorboats to monitor the quality of coastal water and patrol and maintenance of the navigation -aiding facility, which has the problems of high energy consumption, small range of cruise for monitoring, insufficient information control and low visualization. In recent years, the application of UAS in the maritime field has alleviated the phenomenon above to some extent. A cluster-based unmanned network monitoring cruise system designed in this project uses the floating small UAV self-powered launching platform as a carrier, applys the idea of cluster, and combines the strong controllability of the multi-rotor UAV and the capability to carry customized modules, constituting a unmanned, visualized and normalized monitoring cruise network to realize the functions of maritime cruise, maintenance of navigational-aiding and monitoring the quality of coastal water.

  10. Satellite global monitoring of environmental quality

    NASA Technical Reports Server (NTRS)

    Schiffer, R. A.

    1975-01-01

    The missions of two NASA satellites for the monitoring of environmental quality are described: Nimbus G, the Air Pollution and Oceanographic Observing Satellite, and the Applications Explorer Mission (AEM) satellite to be used in the Stratospheric Aerosol and Gas Experiment (SAGE). The scientific payload of Nimbus G is described in detail with a discussion of limb infrared monitoring of the stratosphere, the stratospheric and mesospheric sounder, stratospheric aerosol measurement, the solar and backscatter UV spectrometer for ozone mapping, the earth radiation budget experiment, the scanning multichannel microwave radiometer, the coastal zone color scanner and the temperature-humidity infrared radiometer. A brief description is given of the SAGE program and future NASA plans relating to the global monitoring of environmental quality are outlined.

  11. Tribal Air Quality Monitoring.

    ERIC Educational Resources Information Center

    Wall, Dennis

    2001-01-01

    The Institute for Tribal Environmental Professionals (ITEP) (Flagstaff, Arizona) provides training and support for tribal professionals in the technical job skills needed for air quality monitoring and other environmental management tasks. ITEP also arranges internships, job placements, and hands-on training opportunities and supports an…

  12. New solutions for standardization, monitoring and quality management of fluorescence-based imaging systems (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Royon, Arnaud; Papon, Gautier

    2016-03-01

    Fluorescence microscopes have become ubiquitous in life sciences laboratories, including those focused on pharmaceuticals, diagnosis, and forensics. For the past few years, the need for both performance guarantees and quantifiable results has driven development in this area. However, the lack of appropriate standards and reference materials makes it difficult or impossible to compare the results of two fluorescence microscopes, or to measure performance fluctuations of one microscope over time. Therefore, the operation of fluorescence microscopes is not monitored as often as their use warrants - an issue that is recognized by both systems manufacturers and national metrology institutes. We have developed a new process that enables the etching of long-term stable fluorescent patterns with sub-micrometer sizes in three dimensions inside glass. In this paper, we present, based on this new process, a fluorescent multi-dimensional ruler and a dedicated software that are suitable for monitoring and quality management of fluorescence-based imaging systems (wide-field, confocal, multiphoton, high content machines). In addition to fluorescence, the same patterns exhibit bright- and dark-field contrast, DIC, and phase contrast, which make them also relevant to monitor these types of microscopes. Non-exhaustively, this new solution enables the measurement of: The stage repositioning accuracy; The illumination and detection homogeneities; The field flatness; The detectors' characteristics; The lateral and axial spatial resolutions; The spectral response (spectrum, intensity and lifetime) of the system. Thanks to the stability of the patterns, microscope performance assessment can be carried out as well in a daily basis as in the long term.

  13. Ultrasonic Real-Time Quality Monitoring Of Aluminum Spot Weld Process

    NASA Astrophysics Data System (ADS)

    Perez Regalado, Waldo Josue

    The real-time ultrasonic spot weld monitoring system, introduced by our research group, has been designed for the unsupervised quality characterization of the spot welding process. It comprises the ultrasonic transducer (probe) built into one of the welding electrodes and an electronics hardware unit which gathers information from the transducer, performs real-time weld quality characterization and communicates with the robot programmable logic controller (PLC). The system has been fully developed for the inspection of spot welds manufactured in steel alloys, and has been mainly applied in the automotive industry. In recent years, a variety of materials have been introduced to the automotive industry. These include high strength steels, magnesium alloys, and aluminum alloys. Aluminum alloys have been of particular interest due to their high strength-to-weight ratio. Resistance spot welding requirements for aluminum vary greatly from those of steel. Additionally, the oxide film formed on the aluminum surface increases the heat generation between the copper electrodes and the aluminum plates leading to accelerated electrode deterioration. Preliminary studies showed that the real-time quality inspection system was not able to monitor spot welds manufactured with aluminum. The extensive experimental research, finite element modelling of the aluminum welding process and finite difference modeling of the acoustic wave propagation through the aluminum spot welds presented in this dissertation, revealed that the thermodynamics and hence the acoustic wave propagation through an aluminum and a steel spot weld differ significantly. For this reason, the hardware requirements and the algorithms developed to determine the welds quality from the ultrasonic data used on steel, no longer apply on aluminum spot welds. After updating the system and designing the required algorithms, parameters such as liquid nugget penetration and nugget diameter were available in the ultrasonic data

  14. Integrated Analysis Tools for the NERRS System-Wide Monitoring Program Data

    EPA Science Inventory

    Standardized monitoring programs have vastly improved the quantity and quality of data that form the basis of environmental decision-making. One example is the NOAA-funded National Estuarine Research Reserve System (NERRS) System-wide Monitoring Program (SWMP) that was implement...

  15. A new approach to power quality and electricity reliability monitoring-case study illustrations of the capabilities of the I-GridTM system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Divan, Deepak; Brumsickle, William; Eto, Joseph

    2003-04-01

    This report describes a new approach for collecting information on power quality and reliability and making it available in the public domain. Making this information readily available in a form that is meaningful to electricity consumers is necessary for enabling more informed private and public decisions regarding electricity reliability. The system dramatically reduces the cost (and expertise) needed for customers to obtain information on the most significant power quality events, called voltage sags and interruptions. The system also offers widespread access to information on power quality collected from multiple sites and the potential for capturing information on the impacts ofmore » power quality problems, together enabling a wide variety of analysis and benchmarking to improve system reliability. Six case studies demonstrate selected functionality and capabilities of the system, including: Linking measured power quality events to process interruption and downtime; Demonstrating the ability to correlate events recorded by multiple monitors to narrow and confirm the causes of power quality events; and Benchmarking power quality and reliability on a firm and regional basis.« less

  16. The key incident monitoring and management system - history and role in quality improvement.

    PubMed

    Badrick, Tony; Gay, Stephanie; Mackay, Mark; Sikaris, Ken

    2018-01-26

    The determination of reliable, practical Quality Indicators (QIs) from presentation of the patient with a pathology request form through to the clinician receiving the report (the Total Testing Process or TTP) is a key step in identifying areas where improvement is necessary in laboratories. The Australasian QIs programme Key Incident Monitoring and Management System (KIMMS) began in 2008. It records incidents (process defects) and episodes (occasions at which incidents may occur) to calculate incident rates. KIMMS also uses the Failure Mode Effects Analysis (FMEA) to assign quantified risk to each incident type. The system defines risk as incident frequency multiplied by both a harm rating (on a 1-10 scale) and detection difficulty score (also a 1-10 scale). Between 2008 and 2016, laboratories participating rose from 22 to 69. Episodes rose from 13.2 to 43.4 million; incidents rose from 114,082 to 756,432. We attribute the rise in incident rate from 0.86% to 1.75% to increased monitoring. Haemolysis shows the highest incidence (22.6% of total incidents) and the highest risk (26.68% of total risk). "Sample is suspected to be from the wrong patient" has the second lowest frequency, but receives the highest harm rating (10/10) and detection difficulty score (10/10), so it is calculated to be the 8th highest risk (2.92%). Similarly, retracted (incorrect) reports QI has the 10th highest frequency (3.9%) but the harm/difficulty calculation confers the second highest risk (11.17%). TTP incident rates are generally low (less than 2% of observed episodes), however, incident risks, their frequencies multiplied by both ratings of harm and discovery difficulty scores, concentrate improvement attention and resources on the monitored incident types most important to manage.

  17. Identification and description of potential ground-water quality monitoring wells in Florida

    USGS Publications Warehouse

    Seaber, P.R.; Thagard, M.E.

    1986-01-01

    The results of a survey of existing wells in Florida that meet the following criteria are presented: (1) well location is known , (2) principal aquifer is known, (3) depth of well is known, (4) well casing depth is known, (5) well water had been analyzed between 1970 and 1982, and (6) well data are stored in the U.S. Geological Survey 's (USGS) computer files. Information for more than 20,000 wells in Florida were stored in the USGS Master Water Data Index of the National Water Data Exchange and in the National Water Data Storage and Retrieval System 's Groundwater Site Inventory computerized files in 1982. Wells in these computer files that had been sampled for groundwater quality before November 1982 in Florida number 13,739; 1,846 of these wells met the above criteria and are the potential (or candidate) groundwater quality monitoring wells included in this report. The distribution by principal aquifer of the 1,846 wells identified as potential groundwater quality monitoring wells is as follows: 1,022 tap the Floridan aquifer system, 114 tap the intermediate aquifers, 232 tap the surficial aquifers, 246 tap the Biscayne aquifer, and 232 tap the sand-and-gravel aquifer. These wells are located in 59 of Florida 's 67 counties. This report presents the station descriptions, which include location , site characteristics, period of record, and the type and frequency of chemical water quality data collected for each well. The 1,846 well locations are plotted on 14 USGS 1:250,000 scale, 1 degree by 2 degree, quadrangle maps. This relatively large number of potential (or candidate) monitoring wells, geographically and geohydrologically dispersed, provides a basis for a future groundwater quality monitoring network and computerized data base for Florida. There is a large variety of water quality determinations available from these wells, both areally and temporally. Future sampling of these wells would permit analyses of time and areal trends for selected water quality

  18. Water quality monitoring strategies - A review and future perspectives.

    PubMed

    Behmel, S; Damour, M; Ludwig, R; Rodriguez, M J

    2016-11-15

    The reliable assessment of water quality through water quality monitoring programs (WQMPs) is crucial in order for decision-makers to understand, interpret and use this information in support of their management activities aiming at protecting the resource. The challenge of water quality monitoring has been widely addressed in the literature since the 1940s. However, there is still no generally accepted, holistic and practical strategy to support all phases of WQMPs. The purpose of this paper is to report on the use cases a watershed manager has to address to plan or optimize a WQMP from the challenge of identifying monitoring objectives; selecting sampling sites and water quality parameters; identifying sampling frequencies; considering logistics and resources to the implementation of actions based on information acquired through the WQMP. An inventory and critique of the information, approaches and tools placed at the disposal of watershed managers was proposed to evaluate how the existing information could be integrated in a holistic, user-friendly and evolvable solution. Given the differences in regulatory requirements, water quality standards, geographical and geological differences, land-use variations, and other site specificities, a one-in-all solution is not possible. However, we advance that an intelligent decision support system (IDSS) based on expert knowledge that integrates existing approaches and past research can guide a watershed manager through the process according to his/her site-specific requirements. It is also necessary to tap into local knowledge and to identify the knowledge needs of all the stakeholders through participative approaches based on geographical information systems and adaptive survey-based questionnaires. We believe that future research should focus on developing such participative approaches and further investigate the benefits of IDSS's that can be updated quickly and make it possible for a watershed manager to obtain a

  19. Optimizing an estuarine water quality monitoring program through an entropy-based hierarchical spatiotemporal Bayesian framework

    NASA Astrophysics Data System (ADS)

    Alameddine, Ibrahim; Karmakar, Subhankar; Qian, Song S.; Paerl, Hans W.; Reckhow, Kenneth H.

    2013-10-01

    The total maximum daily load program aims to monitor more than 40,000 standard violations in around 20,000 impaired water bodies across the United States. Given resource limitations, future monitoring efforts have to be hedged against the uncertainties in the monitored system, while taking into account existing knowledge. In that respect, we have developed a hierarchical spatiotemporal Bayesian model that can be used to optimize an existing monitoring network by retaining stations that provide the maximum amount of information, while identifying locations that would benefit from the addition of new stations. The model assumes the water quality parameters are adequately described by a joint matrix normal distribution. The adopted approach allows for a reduction in redundancies, while emphasizing information richness rather than data richness. The developed approach incorporates the concept of entropy to account for the associated uncertainties. Three different entropy-based criteria are adopted: total system entropy, chlorophyll-a standard violation entropy, and dissolved oxygen standard violation entropy. A multiple attribute decision making framework is adopted to integrate the competing design criteria and to generate a single optimal design. The approach is implemented on the water quality monitoring system of the Neuse River Estuary in North Carolina, USA. The model results indicate that the high priority monitoring areas identified by the total system entropy and the dissolved oxygen violation entropy criteria are largely coincident. The monitoring design based on the chlorophyll-a standard violation entropy proved to be less informative, given the low probabilities of violating the water quality standard in the estuary.

  20. Citizen Science Opportunities for Monitoring Air Quality Fact Sheet

    EPA Pesticide Factsheets

    The Citizen Science Opportunities for Monitoring Air Quality fact sheet provides information on what citizen science is and the tools and resources available for citizen scientists interested in monitoring air quality.

  1. DEPLOYMENT OF A WATER QUALITY EARLY WARNING SYSTEM USING ON-LINE TOXICITY MONITORS

    EPA Science Inventory

    Contaminants are of concern when they are found in concentrations that are toxic to plants and/or animals. On–line Toxicity Monitors (OTMs) integrate all factors resulting in stress including physical and chemical qualities. This is important because of the limitations of c...

  2. A Modular IoT Platform for Real-Time Indoor Air Quality Monitoring.

    PubMed

    Benammar, Mohieddine; Abdaoui, Abderrazak; Ahmad, Sabbir H M; Touati, Farid; Kadri, Abdullah

    2018-02-14

    The impact of air quality on health and on life comfort is well established. In many societies, vulnerable elderly and young populations spend most of their time indoors. Therefore, indoor air quality monitoring (IAQM) is of great importance to human health. Engineers and researchers are increasingly focusing their efforts on the design of real-time IAQM systems using wireless sensor networks. This paper presents an end-to-end IAQM system enabling measurement of CO₂, CO, SO₂, NO₂, O₃, Cl₂, ambient temperature, and relative humidity. In IAQM systems, remote users usually use a local gateway to connect wireless sensor nodes in a given monitoring site to the external world for ubiquitous access of data. In this work, the role of the gateway in processing collected air quality data and its reliable dissemination to end-users through a web-server is emphasized. A mechanism for the backup and the restoration of the collected data in the case of Internet outage is presented. The system is adapted to an open-source Internet-of-Things (IoT) web-server platform, called Emoncms, for live monitoring and long-term storage of the collected IAQM data. A modular IAQM architecture is adopted, which results in a smart scalable system that allows seamless integration of various sensing technologies, wireless sensor networks (WSNs) and smart mobile standards. The paper gives full hardware and software details of the proposed solution. Sample IAQM results collected in various locations are also presented to demonstrate the abilities of the system.

  3. A Modular IoT Platform for Real-Time Indoor Air Quality Monitoring

    PubMed Central

    Abdaoui, Abderrazak; Ahmad, Sabbir H.M.; Touati, Farid; Kadri, Abdullah

    2018-01-01

    The impact of air quality on health and on life comfort is well established. In many societies, vulnerable elderly and young populations spend most of their time indoors. Therefore, indoor air quality monitoring (IAQM) is of great importance to human health. Engineers and researchers are increasingly focusing their efforts on the design of real-time IAQM systems using wireless sensor networks. This paper presents an end-to-end IAQM system enabling measurement of CO2, CO, SO2, NO2, O3, Cl2, ambient temperature, and relative humidity. In IAQM systems, remote users usually use a local gateway to connect wireless sensor nodes in a given monitoring site to the external world for ubiquitous access of data. In this work, the role of the gateway in processing collected air quality data and its reliable dissemination to end-users through a web-server is emphasized. A mechanism for the backup and the restoration of the collected data in the case of Internet outage is presented. The system is adapted to an open-source Internet-of-Things (IoT) web-server platform, called Emoncms, for live monitoring and long-term storage of the collected IAQM data. A modular IAQM architecture is adopted, which results in a smart scalable system that allows seamless integration of various sensing technologies, wireless sensor networks (WSNs) and smart mobile standards. The paper gives full hardware and software details of the proposed solution. Sample IAQM results collected in various locations are also presented to demonstrate the abilities of the system. PMID:29443893

  4. Water-quality control, monitoring and wastewater treatment in Lithuania 1950 to 1999.

    PubMed

    Cetkauskaite, A; Zarkov, D; Stoskus, L

    2001-08-01

    The Lithuanian water-management system developed on the basis of Soviet regulations in 1950-1990. Surface-water quality monitoring started in the 1950s, and the system was improved in the 1960s. Today, 48 rivers are being monitored using up to 70 parameters. Statutory monitoring of discharges started in 1962, wastewater standards were issued in 1957 and 1966, and then revised in 1996. Wastewater-treatment plants were built first in rural areas, in factories since the 1950s, and later in towns. Since 1991, large capacity municipal plants have been constructed with foreign assistance. Water quality has improved in some rivers since 1970, but Lithuania's main river, Nemunas, remains moderately polluted. The lower Nemunas is especially affected by discharges of municipal and industrial wastewater from Sovietsk and Neman (Russia), which account for half of the total loading. Hydrobiological data of 1994-1998 indicated the eutrophication of the Curonian Lagoon, and bacteriological pollution and blue-green algae blooms in the Baltic Sea north of Klaipeda.

  5. Air quality monitor and acid rain networks

    NASA Technical Reports Server (NTRS)

    Rudolph, H.

    1980-01-01

    The air quality monitor program which consists of two permanent air monitor stations (PAMS's) and four mobile shuttle pollutant air monitor stations (SPAMS's) is evaluated. The PAMS measures SO sub X, NO sub X particulates, CO, O3, and nonmethane hydrocarbons. The SPAMS measures O3, SO2, HCl, and particulates. The collection and analysis of data in the rain monitor program are discussed.

  6. DICOM index tracker enterprise: advanced system for enterprise-wide quality assurance and patient safety monitoring

    NASA Astrophysics Data System (ADS)

    Zhang, Min; Pavlicek, William; Panda, Anshuman; Langer, Steve G.; Morin, Richard; Fetterly, Kenneth A.; Paden, Robert; Hanson, James; Wu, Lin-Wei; Wu, Teresa

    2015-03-01

    DICOM Index Tracker (DIT) is an integrated platform to harvest rich information available from Digital Imaging and Communications in Medicine (DICOM) to improve quality assurance in radiology practices. It is designed to capture and maintain longitudinal patient-specific exam indices of interests for all diagnostic and procedural uses of imaging modalities. Thus, it effectively serves as a quality assurance and patient safety monitoring tool. The foundation of DIT is an intelligent database system which stores the information accepted and parsed via a DICOM receiver and parser. The database system enables the basic dosimetry analysis. The success of DIT implementation at Mayo Clinic Arizona calls for the DIT deployment at the enterprise level which requires significant improvements. First, for geographically distributed multi-site implementation, the first bottleneck is the communication (network) delay; the second is the scalability of the DICOM parser to handle the large volume of exams from different sites. To address this issue, DICOM receiver and parser are separated and decentralized by site. To facilitate the enterprise wide Quality Assurance (QA), a notable challenge is the great diversities of manufacturers, modalities and software versions, as the solution DIT Enterprise provides the standardization tool for device naming, protocol naming, physician naming across sites. Thirdly, advanced analytic engines are implemented online which support the proactive QA in DIT Enterprise.

  7. Region 7 States Air Quality Monitoring Plans - Iowa

    EPA Pesticide Factsheets

    National Ambient Air Quality Standard (NAAQS) - Iowa, Kansas, Missouri, and Nebraska; Annual Monitoring Network Plans, Five-Year Monitoring Network Assessments, and approval documentation. Each year, states are required to submit an annual monitoring netwo

  8. Region 7 States Air Quality Monitoring Plans - Missouri

    EPA Pesticide Factsheets

    National Ambient Air Quality Standard (NAAQS) - Iowa, Kansas, Missouri, and Nebraska; Annual Monitoring Network Plans, Five-Year Monitoring Network Assessments, and approval documentation. Each year, states are required to submit an annual monitoring netwo

  9. Region 7 States Air Quality Monitoring Plans - Nebraska

    EPA Pesticide Factsheets

    National Ambient Air Quality Standard (NAAQS) - Iowa, Kansas, Missouri, and Nebraska; Annual Monitoring Network Plans, Five-Year Monitoring Network Assessments, and approval documentation. Each year, states are required to submit an annual monitoring netwo

  10. Region 7 States Air Quality Monitoring Plans - Kansas

    EPA Pesticide Factsheets

    National Ambient Air Quality Standard (NAAQS) - Iowa, Kansas, Missouri, and Nebraska; Annual Monitoring Network Plans, Five-Year Monitoring Network Assessments, and approval documentation. Each year, states are required to submit an annual monitoring netwo

  11. A Water Quality Monitoring Programme for Schools and Communities

    ERIC Educational Resources Information Center

    Spellerberg, Ian; Ward, Jonet; Smith, Fiona

    2004-01-01

    A water quality monitoring programme for schools is described. The purpose of the programme is to introduce school children to the concept of reporting on the "state of the environment" by raising the awareness of water quality issues and providing skills to monitor water quality. The programme is assessed and its relevance in the…

  12. Continuous emission monitoring and accounting automated systems at an HPP

    NASA Astrophysics Data System (ADS)

    Roslyakov, P. V.; Ionkin, I. L.; Kondrateva, O. E.; Borovkova, A. M.; Seregin, V. A.; Morozov, I. V.

    2015-03-01

    Environmental and industrial emission monitoring at HPP's is a very urgent task today. Industrial monitoring assumes monitoring of emissions of harmful pollutants and optimization of fuel combustion technological processes at HPP's. Environmental monitoring is a system to assess ambient air quality with respect to a number of separate sources of harmful substances in pollution of atmospheric air of the area. Works on creating an industrial monitoring system are carried out at the National Research University Moscow Power Engineering Institute (MPEI) on the basis of the MPEI combined heat and power plant, and environmental monitoring stations are installed in Lefortovo raion, where the CHPP is located.

  13. A Context-Aware Indoor Air Quality System for Sudden Infant Death Syndrome Prevention

    PubMed Central

    De Paz, Juan F.; Barriuso, Alberto L.

    2018-01-01

    Context-aware monitoring systems designed for e-Health solutions and ambient assisted living (AAL) play an important role in today’s personalized health-care services. The majority of these systems are intended for the monitoring of patients’ vital signs by means of bio-sensors. At present, there are very few systems that monitor environmental conditions and air quality in the homes of users. A home’s environmental conditions can have a significant influence on the state of the health of its residents. Monitoring the environment is the key to preventing possible diseases caused by conditions that do not favor health. This paper presents a context-aware system that monitors air quality to prevent a specific health problem at home. The aim of this system is to reduce the incidence of the Sudden Infant Death Syndrome, which is triggered mainly by environmental factors. In the conducted case study, the system monitored the state of the neonate and the quality of air while it was asleep. The designed proposal is characterized by its low cost and non-intrusive nature. The results are promising. PMID:29498653

  14. A Context-Aware Indoor Air Quality System for Sudden Infant Death Syndrome Prevention.

    PubMed

    De La Iglesia, Daniel H; De Paz, Juan F; Villarrubia González, Gabriel; Barriuso, Alberto L; Bajo, Javier

    2018-03-02

    Context-aware monitoring systems designed for e-Health solutions and ambient assisted living (AAL) play an important role in today's personalized health-care services. The majority of these systems are intended for the monitoring of patients' vital signs by means of bio-sensors. At present, there are very few systems that monitor environmental conditions and air quality in the homes of users. A home's environmental conditions can have a significant influence on the state of the health of its residents. Monitoring the environment is the key to preventing possible diseases caused by conditions that do not favor health. This paper presents a context-aware system that monitors air quality to prevent a specific health problem at home. The aim of this system is to reduce the incidence of the Sudden Infant Death Syndrome, which is triggered mainly by environmental factors. In the conducted case study, the system monitored the state of the neonate and the quality of air while it was asleep. The designed proposal is characterized by its low cost and non-intrusive nature. The results are promising.

  15. Analytical approaches to quality assurance and quality control in rangeland monitoring data

    USDA-ARS?s Scientific Manuscript database

    Producing quality data to support land management decisions is the goal of every rangeland monitoring program. However, the results of quality assurance (QA) and quality control (QC) efforts to improve data quality are rarely reported. The purpose of QA and QC is to prevent and describe non-sampling...

  16. South Asia transboundary water quality monitoring workshop summary report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Betsill, Jeffrey David; Littlefield, Adriane C.; Luetters, Frederick O.

    2003-04-01

    The Cooperative Monitoring Center (CMC) promotes collaborations among scientists and researchers in several regions as a means of achieving common regional security objectives. To promote cooperation in South Asia on environmental research, an international working group made up of participants from Bangladesh, India, Nepal, Pakistan, and the United States convened in Kathmandu, Nepal, from February 17-23,2002. The workshop was held to further develop the South Asia Transboundary Water Quality Monitoring (SATWQM) project. The project is sponsored in part by the CMC located at Sandia National Laboratories in Albuquerque, New Mexico through funding provided by the US. Department of State, Regionalmore » Environmental Affairs Office, American Embassy, Kathmandu, Nepal, and the National Nuclear Security Administration's (NNSA) Office of Nonproliferation and National Security. This report summarizes the SATWQM project, the workshop objectives, process and results. The long-term interests of the participants are to develop systems for sharing regional environmental information as a means of building confidence and improving relations among South Asian countries. The more immediate interests of the group are focused on activities that foster regional sharing of water quality data in the Ganges and Indus River basins. Issues of concern to the SATWQM network participants include studying the impacts from untreated sewage and industrial effluents, agricultural run-off, salinity increases in fresh waters, the siltation and shifting of river channels, and the environmental degradation of critical habitats such as wetlands, protected forests, and endangered aquatic species conservation areas. The workshop focused on five objectives: (1) a deepened understanding of the partner organizations involved; (2) garnering the support of additional regional and national government and non-government organizations in South Asia involved in river water quality monitoring; (3

  17. Water-quality monitoring of Sweetwater Reservoir

    USGS Publications Warehouse

    Majewski, Michael

    2001-01-01

    Sweetwater Authority is concerned with the quality of water it provides to its customers. Results from the water-quality monitoring study that the USGS is conducting in the Sweetwater watershed show that the contaminant concentrations in bed sediments, water, and air are reflected in increased urbanization. The bed sediments show the most dramatic evidence of this impact with a sharp increase of persistent organic chemical concentrations over the past 65 years. Water quality is also affected by urbanization in the form of chemicals in the runoff water and deposition of airborne chemicals. The concentrations of the detected organic chemicals in Sweetwater and Loveland Reservoirs are all well below the guidance limits set by State and Federal agencies to protect human health. Many of these compounds are detected only because of the sensitive analytical methods used. This monitoring program provides the Sweetwater Authority with information on what monitored chemicals are present in the reservoirs, and at what concentrations. With this information, the Authority can assess the associated risks, and consider future water treatment and remediation. These results also help focus and support future efforts by Sweetwater Authority to protect the watershed.

  18. [Monitoring evaluation system for high-specialty hospitals].

    PubMed

    Fajardo Dolci, Germán; Aguirre Gas, Héctor G; Robledo Galván, Héctor

    2011-01-01

    Hospital evaluation is a fundamental process to identify medical units' objective compliance, to analyze efficiency of resource use and allocation, institutional values and mission alignment, patient safety and quality standards, contributions to research and medical education, and the degree of coordination among medical units and the health system as a whole. We propose an evaluation system for highly specialized regional hospitals through the monitoring of performance indicators. The following are established as base thematic elements in the construction of indicators: safe facilities and equipment, financial situation, human resources management, policy management, organizational climate, clinical activity, quality and patient safety, continuity of care, patients' and providers' rights and obligations, teaching, research, social responsibility, coordination mechanisms. Monitoring refers to the planned and systematic evaluation of valid and reliable indicators, aimed at identifying problems and opportunity areas. Moreover, evaluation is a powerful tool to strengthen decision-making and accountability in medical units.

  19. Effect of quality metric monitoring and colonoscopy performance.

    PubMed

    Razzak, Anthony; Smith, Dineen; Zahid, Maliha; Papachristou, Georgios; Khalid, Asif

    2016-10-01

    Background and aims: Adenoma detection rate (ADR) and cecal withdrawal time (CWT) have been identified as measures of colonoscopy quality. This study evaluates the impact of monitoring these measures on provider performance. Methods: Six blinded gastroenterologists practicing at a Veterans Affairs Medical Center were prospectively monitored over 9 months. Data for screening, adenoma surveillance, and fecal occult blood test positive (FOBT +) indicated colonoscopies were obtained, including exam preparation quality, cecal intubation rate, CWT, ADR, adenomas per colonoscopy (APC), and adverse events. Metrics were continuously monitored after a period of informed CWT monitoring and informed CWT + ADR monitoring. The primary outcome was impact on ADR and APC. Results: A total of 1671 colonoscopies were performed during the study period with 540 before informed monitoring, 528 during informed CWT monitoring, and 603 during informed CWT + ADR monitoring. No statistically significant impact on ADR was noted across each study phase. Multivariate regression revealed a trend towards fewer adenomas removed during the CWT monitoring phase (OR = 0.79; 95 %CI 0.62 - 1.02, P  = 0.065) and a trend towards more adenomas removed during the CWT + ADR monitoring phase when compared to baseline (OR = 1.26; 95 %CI 0.99 - 1.61, P  = 0.062). Indication for examination and provider were significant predictors for higher APC. Provider-specific data demonstrated a direct relationship between high ADR performers and increased CWT. Conclusions: Monitoring quality metrics did not significantly alter colonoscopy performance across a small heterogeneous group of providers. Non-significant trends towards higher APC were noted with CWT + ADR monitoring. Providers with a longer CWT had a higher ADR. Further studies are needed to determine the impact of monitoring on colonoscopy performance.

  20. An intelligent remote monitoring system for artificial heart.

    PubMed

    Choi, Jaesoon; Park, Jun W; Chung, Jinhan; Min, Byoung G

    2005-12-01

    A web-based database system for intelligent remote monitoring of an artificial heart has been developed. It is important for patients with an artificial heart implant to be discharged from the hospital after an appropriate stabilization period for better recovery and quality of life. Reliable continuous remote monitoring systems for these patients with life support devices are gaining practical meaning. The authors have developed a remote monitoring system for this purpose that consists of a portable/desktop monitoring terminal, a database for continuous recording of patient and device status, a web-based data access system with which clinicians can access real-time patient and device status data and past history data, and an intelligent diagnosis algorithm module that noninvasively estimates blood pump output and makes automatic classification of the device status. The system has been tested with data generation emulators installed on remote sites for simulation study, and in two cases of animal experiments conducted at remote facilities. The system showed acceptable functionality and reliability. The intelligence algorithm also showed acceptable practicality in an application to animal experiment data.

  1. Quality assurance: Importance of systems and standard operating procedures

    PubMed Central

    Manghani, Kishu

    2011-01-01

    It is mandatory for sponsors of clinical trials and contract research organizations alike to establish, manage and monitor their quality control and quality assurance systems and their integral standard operating procedures and other quality documents to provide high-quality products and services to fully satisfy customer needs and expectations. Quality control and quality assurance systems together constitute the key quality systems. Quality control and quality assurance are parts of quality management. Quality control is focused on fulfilling quality requirements, whereas quality assurance is focused on providing confidence that quality requirements are fulfilled. The quality systems must be commensurate with the Company business objectives and business model. Top management commitment and its active involvement are critical in order to ensure at all times the adequacy, suitability, effectiveness and efficiency of the quality systems. Effective and efficient quality systems can promote timely registration of drugs by eliminating waste and the need for rework with overall financial and social benefits to the Company. PMID:21584180

  2. Quality assurance: Importance of systems and standard operating procedures.

    PubMed

    Manghani, Kishu

    2011-01-01

    It is mandatory for sponsors of clinical trials and contract research organizations alike to establish, manage and monitor their quality control and quality assurance systems and their integral standard operating procedures and other quality documents to provide high-quality products and services to fully satisfy customer needs and expectations. Quality control and quality assurance systems together constitute the key quality systems. Quality control and quality assurance are parts of quality management. Quality control is focused on fulfilling quality requirements, whereas quality assurance is focused on providing confidence that quality requirements are fulfilled. The quality systems must be commensurate with the Company business objectives and business model. Top management commitment and its active involvement are critical in order to ensure at all times the adequacy, suitability, effectiveness and efficiency of the quality systems. Effective and efficient quality systems can promote timely registration of drugs by eliminating waste and the need for rework with overall financial and social benefits to the Company.

  3. Discontinuous and Continuous Indoor Air Quality Monitoring in Homes with Fireplaces or Wood Stoves as Heating System.

    PubMed

    de Gennaro, Gianluigi; Dambruoso, Paolo Rosario; Di Gilio, Alessia; Di Palma, Valerio; Marzocca, Annalisa; Tutino, Maria

    2015-12-24

    Around 50% of the world's population, particularly in developing countries, uses biomass as one of the most common fuels. Biomass combustion releases a considerable amount of various incomplete combustion products, including particulate matter (PM) and polycyclic aromatic hydrocarbons (PAHs). The paper presents the results of Indoor Air Quality (IAQ) measurements in six houses equipped with wood burning stoves or fireplaces as heating systems. The houses were monitored for 48-h periods in order to collect PM10 samples and measure PAH concentrations. The average, the maximum and the lowest values of the 12-h PM10 concentration were 68.6 μg/m³, 350.7 μg/m³ and 16.8 μg/m³ respectively. The average benzo[a]pyrene 12-h concentration was 9.4 ng/m³, while the maximum and the minimum values were 24.0 ng/m³ and 1.5 ng/m³, respectively. Continuous monitoring of PM10, PAHs, Ultra Fine Particle (UFP) and Total Volatile Organic Compounds (TVOC) was performed in order to study the progress of pollution phenomena due to biomass burning, their trends and contributions to IAQ. The results show a great heterogeneity of impacts on IAQ in terms of magnitude and behavior of the considered pollutants' concentrations. This variability is determined by not only different combustion technologies or biomass quality, but overall by different ignition mode, feeding and flame management, which can also be different for the same house. Moreover, room dimensions and ventilation were significant factors for pollution dispersion. The increase of PM10, UFP and PAH concentrations, during lighting, was always detected and relevant. Continuous monitoring allowed singling out contributions of other domestic sources of considered pollutants such as cooking and cigarettes. Cooking contribution produced an impact on IAQ in same cases higher than that of the biomass heating system.

  4. Smart healthcare textile sensor system for unhindered-pervasive health monitoring

    NASA Astrophysics Data System (ADS)

    Rai, Pratyush; Kumar, Prashanth S.; Oh, Sechang; Kwon, Hyeokjun; Mathur, Gyanesh N.; Varadan, Vijay K.; Agarwal, M. P.

    2012-04-01

    Simultaneous monitoring of physiological parameters- multi-lead Electrocardiograph (ECG), Heart rate variability, and blood pressure- is imperative to all forms of medical treatments. Using an array of signal recording devices imply that the patient will have to be confined to a bed. Textiles offer durable platform for embedded sensor and communication systems. The smart healthcare textile, presented here, is a mobile system for remote/wireless data recording and conditioning. The wireless textile system has been designed to monitor a patient in a non-obstructive way. It has a potential for facilitating point of care medicine and streamlining ambulatory medicine. The sensor systems were designed and fabricated with textile based components for easy integration on textile platform. An innovative plethysmographic blood pressure monitoring system was designed and tested as an alternative to inflatable blood pressure sphygmomanometer. Flexible dry electrodes technology was implemented for ECG. The sensor systems were tested and conditioned to daily activities of patients, which is not permissible with halter type systems. The signal quality was assessed for it applicability to medical diagnosis. The results were used to corroborate smart textile sensor system's ability to function as a point of care system that can provide quality healthcare.

  5. 40 CFR 52.995 - Enhanced ambient air quality monitoring.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Enhanced ambient air quality monitoring. 52.995 Section 52.995 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... air quality monitoring. (a) The Governor of the State of Louisiana submitted the photochemical...

  6. 40 CFR 52.995 - Enhanced ambient air quality monitoring.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Enhanced ambient air quality monitoring. 52.995 Section 52.995 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... air quality monitoring. (a) The Governor of the State of Louisiana submitted the photochemical...

  7. 40 CFR 52.995 - Enhanced ambient air quality monitoring.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Enhanced ambient air quality monitoring. 52.995 Section 52.995 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... air quality monitoring. (a) The Governor of the State of Louisiana submitted the photochemical...

  8. 40 CFR 52.995 - Enhanced ambient air quality monitoring.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Enhanced ambient air quality monitoring. 52.995 Section 52.995 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... air quality monitoring. (a) The Governor of the State of Louisiana submitted the photochemical...

  9. 40 CFR 52.995 - Enhanced ambient air quality monitoring.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Enhanced ambient air quality monitoring. 52.995 Section 52.995 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... air quality monitoring. (a) The Governor of the State of Louisiana submitted the photochemical...

  10. Monitoring the Quality of School Buildings in Belgium's Flemish Community

    ERIC Educational Resources Information Center

    Leemans, Geert

    2009-01-01

    In the course of 2008, the Flemish Agency for Infrastructure in Education (AGIOn) evaluated the quality of school buildings in Flanders using a monitoring system based on international experience. The results showed that most school buildings satisfy the basic requirements of habitability and safety, but they often fall short when it comes to the…

  11. Monitoring the CMS strip tracker readout system

    NASA Astrophysics Data System (ADS)

    Mersi, S.; Bainbridge, R.; Baulieu, G.; Bel, S.; Cole, J.; Cripps, N.; Delaere, C.; Drouhin, F.; Fulcher, J.; Giassi, A.; Gross, L.; Hahn, K.; Mirabito, L.; Nikolic, M.; Tkaczyk, S.; Wingham, M.

    2008-07-01

    The CMS Silicon Strip Tracker at the LHC comprises a sensitive area of approximately 200 m2 and 10 million readout channels. Its data acquisition system is based around a custom analogue front-end chip. Both the control and the readout of the front-end electronics are performed by off-detector VME boards in the counting room, which digitise the raw event data and perform zero-suppression and formatting. The data acquisition system uses the CMS online software framework to configure, control and monitor the hardware components and steer the data acquisition. The first data analysis is performed online within the official CMS reconstruction framework, which provides many services, such as distributed analysis, access to geometry and conditions data, and a Data Quality Monitoring tool based on the online physics reconstruction. The data acquisition monitoring of the Strip Tracker uses both the data acquisition and the reconstruction software frameworks in order to provide real-time feedback to shifters on the operational state of the detector, archiving for later analysis and possibly trigger automatic recovery actions in case of errors. Here we review the proposed architecture of the monitoring system and we describe its software components, which are already in place, the various monitoring streams available, and our experiences of operating and monitoring a large-scale system.

  12. Development of Novel Non-Contact Electrodes for Mobile Electrocardiogram Monitoring System

    PubMed Central

    Chou, Willy; Wang, Hsing-Yu; Huang, Yan-Jun; Pan, Jeng-Shyang

    2013-01-01

    Real-time monitoring of cardiac health is helpful for patients with cardiovascular disease. Many telemedicine systems based on ubiquitous computing and communication techniques have been proposed for monitoring the user's electrocardiogram (ECG) anywhere and anytime. Usually, wet electrodes are used in these telemedicine systems. However, wet electrodes require conduction gels and skin preparation that can be inconvenient and uncomfortable for users. In order to overcome this issue, a new non-contact electrode circuit was proposed and applied in developing a mobile electrocardiogram monitoring system. The proposed non-contact electrode can measure bio-potentials across thin clothing, allowing it to be embedded in a user's normal clothing to monitor ECG in daily life. We attempted to simplify the design of these non-contact electrodes to reduce power consumption while continuing to provide good signal quality. The electrical specifications and the performance of monitoring arrhythmia in clinical settings were also validated to investigate the reliability of the proposed design. Experimental results show that the proposed non-contact electrode provides good signal quality for measuring ECG across thin clothes. PMID:27170853

  13. Continuous water quality monitoring for the hard clam industry in Florida, USA.

    PubMed

    Bergquist, Derk C; Heuberger, David; Sturmer, Leslie N; Baker, Shirley M

    2009-01-01

    In 2000, Florida's fast-growing hard clam aquaculture industry became eligible for federal agricultural crop insurance through the US Department of Agriculture, but the responsibility for identifying the cause of mortality remained with the grower. Here we describe the continuous water quality monitoring system used to monitor hard clam aquaculture areas in Florida and show examples of the data collected with the system. Systems recording temperature, salinity, dissolved oxygen, water depth, turbidity and chlorophyll at 30 min intervals were installed at 10 aquaculture lease areas along Florida's Gulf and Atlantic coasts. Six of these systems sent data in real-time to a public website, and all 10 systems provided data for web-accessible archives. The systems documented environmental conditions that could negatively impact clam survival and productivity and identified biologically relevant water quality differences among clam aquaculture areas. Both the real-time and archived data were used widely by clam growers and nursery managers to make management decisions and in filing crop loss insurance claims. While the systems were labor and time intensive, we recommend adjustments that could reduce costs and staff time requirements.

  14. Data-quality measures for stakeholder-implemented watershed-monitoring programs

    USGS Publications Warehouse

    Greve, Adrienne I.

    2002-01-01

    Community-based watershed groups, many of which collect environmental data, have steadily increased in number over the last decade. The data generated by these programs are often underutilized due to uncertainty in the quality of data produced. The incorporation of data-quality measures into stakeholder monitoring programs lends statistical validity to data. Data-quality measures are divided into three steps: quality assurance, quality control, and quality assessment. The quality-assurance step attempts to control sources of error that cannot be directly quantified. This step is part of the design phase of a monitoring program and includes clearly defined, quantifiable objectives, sampling sites that meet the objectives, standardized protocols for sample collection, and standardized laboratory methods. Quality control (QC) is the collection of samples to assess the magnitude of error in a data set due to sampling, processing, transport, and analysis. In order to design a QC sampling program, a series of issues needs to be considered: (1) potential sources of error, (2) the type of QC samples, (3) inference space, (4) the number of QC samples, and (5) the distribution of the QC samples. Quality assessment is the process of evaluating quality-assurance measures and analyzing the QC data in order to interpret the environmental data. Quality assessment has two parts: one that is conducted on an ongoing basis as the monitoring program is running, and one that is conducted during the analysis of environmental data. The discussion of the data-quality measures is followed by an example of their application to a monitoring program in the Big Thompson River watershed of northern Colorado.

  15. ENVIRONMENTAL QUALITY INFORMATION SYSTEM - EQULS® - ITER

    EPA Science Inventory

    This project consisted of an evaluation of the Environmental Quality Information System (EQuIS) software designed by Earthsoft, Inc. as an environmental data management and analysis platform for monitoring and remediation projects. In consultation with the EQuIS vendor, six pri...

  16. Expert Water Quality Panel Review of Responses to the NASA Request for Information for the International Space Station On-Board Environmental Monitoring System

    NASA Technical Reports Server (NTRS)

    Fishman, Julianna L.; Mudgett, Paul D.; Packham, Nigel J.; Schultz, John R.; Straub, John E., II

    2005-01-01

    On August 9, 2003, NASA, with the cooperative support of the Vehicle Office of the International Space Station Program, the Advanced Human Support Technology Program, and the Johnson Space Center Habitability and Environmental Factors Office released a Request for Information, or RFI, to identify next-generation environmental monitoring systems that have demonstrated ability or the potential to meet defined requirements for monitoring air and water quality onboard the International Space Station. This report summarizes the review and analysis of the proposed solutions submitted to meet the water quality monitoring requirements. Proposals were to improve upon the functionality of the existing Space Station Total Organic Carbon Analyzer (TOCA) and monitor additional contaminants in water samples. The TOCA is responsible for in-flight measurement of total organic carbon, total inorganic carbon, total carbon, pH, and conductivity in the Space Station potable water supplies. The current TOCA requires hazardous reagents to accomplish the carbon analyses. NASA is using the request for information process to investigate new technologies that may improve upon existing capabilities, as well as reduce or eliminate the need for hazardous reagents. Ideally, a replacement for the TOCA would be deployed in conjunction with the delivery of the Node 3 water recovery system currently scheduled for November 2007.

  17. An Implementation of the Salt-Farm Monitoring System Using Wireless Sensor Network

    NASA Astrophysics Data System (ADS)

    Ju, Jonggil; Park, Ingon; Lee, Yongwoong; Cho, Jongsik; Cho, Hyunwook; Yoe, Hyun; Shin, Changsun

    In producing solar salt, natural environmental factors such as temperature, humidity, solar radiation, wind direction, wind speed and rain are essential elements which influence on the productivity and quality of salt. If we can manage the above mentioned environmental elements efficiently, we could achieve improved results in production of salt with good quality. To monitor and manage the natural environments, this paper suggests the Salt-Farm Monitoring System (SFMS) which is operated with renewable energy power. The system collects environmental factors directly from the environmental measure sensors and the sensor nodes. To implement a stand-alone system, we applied solar cell and wind generator to operate this system. Finally, we showed that the SFMS could monitor the salt-farm environments by using wireless sensor nodes and operate correctly without external power supply.

  18. MoniQA: a general approach to monitor quality assurance

    NASA Astrophysics Data System (ADS)

    Jacobs, J.; Deprez, T.; Marchal, G.; Bosmans, H.

    2006-03-01

    MoniQA ("Monitor Quality Assurance") is a new, non-commercial, independent quality assurance software application developed in our medical physics team. It is a complete Java TM - based modular environment for the evaluation of radiological viewing devices and it thus fits in the global quality assurance network of our (film less) radiology department. The purpose of the software tool is to guide the medical physicist through an acceptance protocol and the radiologist through a constancy check protocol by presentation of the necessary test patterns and by automated data collection. Data are then sent to a central management system for further analysis. At the moment more than 55 patterns have been implemented, which can be grouped in schemes to implement protocols (i.e. AAPMtg18, DIN and EUREF). Some test patterns are dynamically created and 'drawn' on the viewing device with random parameters as is the case in a recently proposed new pattern for constancy testing. The software is installed on 35 diagnostic stations (70 monitors) in a film less radiology department. Learning time was very limited. A constancy check -with the new pattern that assesses luminance decrease, resolution problems and geometric distortion- takes only 2 minutes and 28 seconds per monitor. The modular approach of the software allows the evaluation of new or emerging test patterns. We will report on the software and its usability: practicality of the constancy check tests in our hospital and on the results from acceptance tests of viewing stations for digital mammography.

  19. Monitoring-well network and sampling design for ground-water quality, Wind River Indian Reservation, Wyoming

    USGS Publications Warehouse

    Mason, Jon P.; Sebree, Sonja K.; Quinn, Thomas L.

    2005-01-01

    The Wind River Indian Reservation, located in parts of Fremont and Hot Springs Counties, Wyoming, has a total land area of more than 3,500 square miles. Ground water on the Wind River Indian Reservation is a valuable resource for Shoshone and Northern Arapahoe tribal members and others who live on the Reservation. There are many types of land uses on the Reservation that have the potential to affect the quality of ground-water resources. Urban areas, rural housing developments, agricultural lands, landfills, oil and natural gas fields, mining, and pipeline utility corridors all have the potential to affect ground-water quality. A cooperative study was developed between the U.S. Geological Survey and the Wind River Environmental Quality Commission to identify areas of the Reservation that have the highest potential for ground-water contamination and develop a comprehensive plan to monitor these areas. An arithmetic overlay model for the Wind River Indian Reservation was created using seven geographic information system data layers representing factors with varying potential to affect ground-water quality. The data layers used were: the National Land Cover Dataset, water well density, aquifer sensitivity, oil and natural gas fields and petroleum pipelines, sites with potential contaminant sources, sites that are known to have ground-water contamination, and National Pollutant Discharge Elimination System sites. A prioritization map for monitoring ground-water quality on the Reservation was created using the model. The prioritization map ranks the priority for monitoring ground-water quality in different areas of the Reservation as low, medium, or high. To help minimize bias in selecting sites for a monitoring well network, an automated stratified random site-selection approach was used to select 30 sites for ground-water quality monitoring within the high priority areas. In addition, the study also provided a sampling design for constituents to be monitored, sampling

  20. Robowell: An automated process for monitoring ground water quality using established sampling protocols

    USGS Publications Warehouse

    Granato, G.E.; Smith, K.P.

    1999-01-01

    Robowell is an automated process for monitoring selected ground water quality properties and constituents by pumping a well or multilevel sampler. Robowell was developed and tested to provide a cost-effective monitoring system that meets protocols expected for manual sampling. The process uses commercially available electronics, instrumentation, and hardware, so it can be configured to monitor ground water quality using the equipment, purge protocol, and monitoring well design most appropriate for the monitoring site and the contaminants of interest. A Robowell prototype was installed on a sewage treatment plant infiltration bed that overlies a well-studied unconfined sand and gravel aquifer at the Massachusetts Military Reservation, Cape Cod, Massachusetts, during a time when two distinct plumes of constituents were released. The prototype was operated from May 10 to November 13, 1996, and quality-assurance/quality-control measurements demonstrated that the data obtained by the automated method was equivalent to data obtained by manual sampling methods using the same sampling protocols. Water level, specific conductance, pH, water temperature, dissolved oxygen, and dissolved ammonium were monitored by the prototype as the wells were purged according to U.S Geological Survey (USGS) ground water sampling protocols. Remote access to the data record, via phone modem communications, indicated the arrival of each plume over a few days and the subsequent geochemical reactions over the following weeks. Real-time availability of the monitoring record provided the information needed to initiate manual sampling efforts in response to changes in measured ground water quality, which proved the method and characterized the screened portion of the plume in detail through time. The methods and the case study described are presented to document the process for future use.

  1. A decision tree model to estimate the value of information provided by a groundwater quality monitoring network

    NASA Astrophysics Data System (ADS)

    Khader, A.; Rosenberg, D.; McKee, M.

    2012-12-01

    Nitrate pollution poses a health risk for infants whose freshwater drinking source is groundwater. This risk creates a need to design an effective groundwater monitoring network, acquire information on groundwater conditions, and use acquired information to inform management. These actions require time, money, and effort. This paper presents a method to estimate the value of information (VOI) provided by a groundwater quality monitoring network located in an aquifer whose water poses a spatially heterogeneous and uncertain health risk. A decision tree model describes the structure of the decision alternatives facing the decision maker and the expected outcomes from these alternatives. The alternatives include: (i) ignore the health risk of nitrate contaminated water, (ii) switch to alternative water sources such as bottled water, or (iii) implement a previously designed groundwater quality monitoring network that takes into account uncertainties in aquifer properties, pollution transport processes, and climate (Khader and McKee, 2012). The VOI is estimated as the difference between the expected costs of implementing the monitoring network and the lowest-cost uninformed alternative. We illustrate the method for the Eocene Aquifer, West Bank, Palestine where methemoglobinemia is the main health problem associated with the principal pollutant nitrate. The expected cost of each alternative is estimated as the weighted sum of the costs and probabilities (likelihoods) associated with the uncertain outcomes resulting from the alternative. Uncertain outcomes include actual nitrate concentrations in the aquifer, concentrations reported by the monitoring system, whether people abide by manager recommendations to use/not-use aquifer water, and whether people get sick from drinking contaminated water. Outcome costs include healthcare for methemoglobinemia, purchase of bottled water, and installation and maintenance of the groundwater monitoring system. At current

  2. Technology transfer potential of an automated water monitoring system. [market research

    NASA Technical Reports Server (NTRS)

    Jamieson, W. M.; Hillman, M. E. D.; Eischen, M. A.; Stilwell, J. M.

    1976-01-01

    The nature and characteristics of the potential economic need (markets) for a highly integrated water quality monitoring system were investigated. The technological, institutional and marketing factors that would influence the transfer and adoption of an automated system were studied for application to public and private water supply, public and private wastewater treatment and environmental monitoring of rivers and lakes.

  3. DOE/NV/26383-LTR2008-01 Letter Report Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Caliente, Lincoln County, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. Engelbrecht; I. Kavouras; D. Campbell

    2009-04-02

    The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Beatty, Sarcobatus Flats, Rachel, Caliente, Pahranagat NWR, Crater Flat, and Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d).more » The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data, on completion of the site's sampling program.« less

  4. A quality monitor and monitoring technique employing optically stimulated electron emission

    NASA Technical Reports Server (NTRS)

    Yost, William T. (Inventor); Welch, Christopher S. (Inventor); Joe, Edmond J. (Inventor); Hefner, Bill Bryan, Jr. (Inventor)

    1995-01-01

    A light source directs ultraviolet light onto a test surface and a detector detects a current of photoelectrons generated by the light. The detector includes a collector which is positively biased with respect to the test surface. Quality is indicated based on the photoelectron current. The collector is then negatively biased to replace charges removed by the measurement of a nonconducting substrate to permit subsequent measurements. Also, the intensity of the ultraviolet light at a particular wavelength is monitored and the voltage of the light source varied to maintain the light a constant desired intensity. The light source is also cooled via a gas circulation system. If the test surface is an insulator, the surface is bombarded with ultraviolet light in the presence of an electron field to remove the majority of negative charges from the surface. The test surface is then exposed to an ion field until it possesses no net charge. The technique described above is then performed to assess quality.

  5. Soil quality monitoring: Examples of existing protocols

    Treesearch

    Daniel G. Neary; Carl C. Trettin; Deborah Page-Dumroese

    2010-01-01

    Many forestry and agricultural agencies and organizations worldwide have developed soil monitoring and quality standards and guidelines to ensure future sustainability of land management. These soil monitoring standards are typically developed in response to international initiatives such as the Montreal Process, the Helsinki Ministerial Conference,or in support of...

  6. Soil quality monitoring: examples of existing protocols

    Treesearch

    Daniel G. Neary; Carl C. Trettin; Deborah Page-Dumroese

    2010-01-01

    Many forestry and agricultural agencies and organizations worldwide have developed soil monitoring and quality standards and guidelines to ensure future sustainability of land management. These soil monitoring standards are typically developed in response to international initiatives such as the Montreal Process, the Helsinki Ministerial Conference, or in support of...

  7. Data Quality Monitoring in Clinical Trials: Has It Been Worth It? An Evaluation and Prediction of the Future by All Stakeholders

    PubMed Central

    Kalali, Amir; West, Mark; Walling, David; Hilt, Dana; Engelhardt, Nina; Alphs, Larry; Loebel, Antony; Vanover, Kim; Atkinson, Sarah; Opler, Mark; Sachs, Gary; Nations, Kari; Brady, Chris

    2016-01-01

    This paper summarizes the results of the CNS Summit Data Quality Monitoring Workgroup analysis of current data quality monitoring techniques used in central nervous system (CNS) clinical trials. Based on audience polls conducted at the CNS Summit 2014, the panel determined that current techniques used to monitor data and quality in clinical trials are broad, uncontrolled, and lack independent verification. The majority of those polled endorse the value of monitoring data. Case examples of current data quality methodology are presented and discussed. Perspectives of pharmaceutical companies and trial sites regarding data quality monitoring are presented. Potential future developments in CNS data quality monitoring are described. Increased utilization of biomarkers as objective outcomes and for patient selection is considered to be the most impactful development in data quality monitoring over the next 10 years. Additional future outcome measures and patient selection approaches are discussed. PMID:27413584

  8. On the matter of the reliability of the chemical monitoring system based on the modern control and monitoring devices

    NASA Astrophysics Data System (ADS)

    Andriushin, A. V.; Dolbikova, N. S.; Kiet, S. V.; Merzlikina, E. I.; Nikitina, I. S.

    2017-11-01

    The reliability of the main equipment of any power station depends on the correct water chemistry. In order to provide it, it is necessary to monitor the heat carrier quality, which, in its turn, is provided by the chemical monitoring system. Thus, the monitoring system reliability plays an important part in providing reliability of the main equipment. The monitoring system reliability is determined by the reliability and structure of its hardware and software consisting of sensors, controllers, HMI and so on [1,2]. Workers of a power plant dealing with the measuring equipment must be informed promptly about any breakdowns in the monitoring system, in this case they are able to remove the fault quickly. A computer consultant system for personnel maintaining the sensors and other chemical monitoring equipment can help to notice faults quickly and identify their possible causes. Some technical solutions for such a system are considered in the present paper. The experimental results were obtained on the laboratory and experimental workbench representing a physical model of a part of the chemical monitoring system.

  9. Laser beam welding quality monitoring system based in high-speed (10 kHz) uncooled MWIR imaging sensors

    NASA Astrophysics Data System (ADS)

    Linares, Rodrigo; Vergara, German; Gutiérrez, Raúl; Fernández, Carlos; Villamayor, Víctor; Gómez, Luis; González-Camino, Maria; Baldasano, Arturo; Castro, G.; Arias, R.; Lapido, Y.; Rodríguez, J.; Romero, Pablo

    2015-05-01

    The combination of flexibility, productivity, precision and zero-defect manufacturing in future laser-based equipment are a major challenge that faces this enabling technology. New sensors for online monitoring and real-time control of laserbased processes are necessary for improving products quality and increasing manufacture yields. New approaches to fully automate processes towards zero-defect manufacturing demand smarter heads where lasers, optics, actuators, sensors and electronics will be integrated in a unique compact and affordable device. Many defects arising in laser-based manufacturing processes come from instabilities in the dynamics of the laser process. Temperature and heat dynamics are key parameters to be monitored. Low cost infrared imagers with high-speed of response will constitute the next generation of sensors to be implemented in future monitoring and control systems for laser-based processes, capable to provide simultaneous information about heat dynamics and spatial distribution. This work describes the result of using an innovative low-cost high-speed infrared imager based on the first quantum infrared imager monolithically integrated with Si-CMOS ROIC of the market. The sensor is able to provide low resolution images at frame rates up to 10 KHz in uncooled operation at the same cost as traditional infrared spot detectors. In order to demonstrate the capabilities of the new sensor technology, a low-cost camera was assembled on a standard production laser welding head, allowing to register melting pool images at frame rates of 10 kHz. In addition, a specific software was developed for defect detection and classification. Multiple laser welding processes were recorded with the aim to study the performance of the system and its application to the real-time monitoring of laser welding processes. During the experiments, different types of defects were produced and monitored. The classifier was fed with the experimental images obtained. Self

  10. On-Orbit MTF Measurement and Product Quality Monitoring for Commercial Remote Sensing Systems

    NASA Technical Reports Server (NTRS)

    Person, Steven

    2007-01-01

    Initialization and opportunistic targets are chosen that represent the MTF on the spatial domain. Ideal targets have simple mathematical relationships. Determine the MTF of an on-orbit satellite using in-scene targets: Slant-Edge, Line Source, point Source, and Radial Target. Attempt to facilitate the MTF calculation by automatically locating targets of opportunity. Incorporate MTF results into a product quality monitoring architecture.

  11. Real-time indoor monitoring system based on wireless sensor networks

    NASA Astrophysics Data System (ADS)

    Wu, Zhengzhong; Liu, Zilin; Huang, Xiaowei; Liu, Jun

    2008-10-01

    Wireless sensor networks (WSN) greatly extend our ability to monitor and control the physical world. It can collaborate and aggregate a huge amount of sensed data to provide continuous and spatially dense observation of environment. The control and monitoring of indoor atmosphere conditions represents an important task with the aim of ensuring suitable working and living spaces to people. However, the comprehensive air quality, which includes monitoring of humidity, temperature, gas concentrations, etc., is not so easy to be monitored and controlled. In this paper an indoor WSN monitoring system was developed. In the system several sensors such as temperature sensor, humidity sensor, gases sensor, were built in a RF transceiver board for monitoring indoor environment conditions. The indoor environmental monitoring parameters can be transmitted by wireless to database server and then viewed throw PC or PDA accessed to the local area networks by administrators. The system, which was also field-tested and showed a reliable and robust characteristic, is significant and valuable to people.

  12. Selection of monitoring locations for storm water quality assessment.

    PubMed

    Langeveld, J G; Boogaard, F; Liefting, H J; Schilperoort, R P S; Hof, A; Nijhof, H; de Ridder, A C; Kuiper, M W

    2014-01-01

    Storm water runoff is a major contributor to the pollution of receiving waters. Storm water characteristics may vary significantly between locations and events. Hence, for each given location, this necessitates a well-designed monitoring campaign prior to selection of an appropriate storm water management strategy. The challenge for the design of a monitoring campaign with a given budget is to balance detailed monitoring at a limited number of locations versus less detailed monitoring at a large number of locations. This paper proposes a methodology for the selection of monitoring locations for storm water quality monitoring, based on (pre-)screening, a quick scan monitoring campaign, and final selection of locations and design of the monitoring setup. The main advantage of the method is the ability to prevent the selection of monitoring locations that turn out to be inappropriate. In addition, in this study, the quick scan resulted in a first useful dataset on storm water quality and a strong indication of illicit connections at one of the monitoring locations.

  13. Water Quality Monitoring Manual.

    ERIC Educational Resources Information Center

    Mason, Fred J.; Houdart, Joseph F.

    This manual is designed for students involved in environmental education programs dealing with water pollution problems. By establishing a network of Environmental Monitoring Stations within the educational system, four steps toward the prevention, control, and abatement of water pollution are proposed. (1) Train students to recognize, monitor,…

  14. Integrated monitoring technologies for the management of a Soil-Aquifer-Treatment (SAT) system.

    NASA Astrophysics Data System (ADS)

    Papadopoulos, Alexandros; Kallioras, Andreas; Kofakis, Petros; Bumberger, Jan; Schmidt, Felix; Athanasiou, Georgios; Uzunoglou, Nikolaos; Amditis, Angelos; Dietrich, Peter

    2016-04-01

    Artificial recharge of groundwater has an important role to play in water reuse as treated wastewater effluent can be infiltrated into the ground for aquifer recharge. As the effluent moves through the soil and the aquifer, it undergoes significant quality improvements through physical, chemical, and biological processes in the underground environment. Collectively, these processes and the water quality improvement obtained are called soil-aquifer-treatment (SAT) or geopurification. The pilot site of Lavrion Technological & Cultural Park (LTCP) of the National Technical University of Athens (NTUA), involves the employment of plot infiltration basins at experimental scale, which will be using waters of impaired quality as a recharge source, and hence acting as a Soil-Aquifer-Treatment, SAT, system. Τhe LTCP site will be employed as a pilot SAT system complemented by new technological developments, which will be providing continuous monitoring of the quantitative and qualitative characteristics of infiltrating groundwater through all hydrologic zones (i.e. surface, unsaturated and saturated zone). This will be achieved by the development and installation of an integrated system of prototype sensing technologies, installed on-site, and offering a continuous evaluation of the performance of the SAT system. An integrated approach of the performance evaluation of any operating SAT system should aim at parallel monitoring of all hydrologic zones, proving the sustainability of all involved water quality treatment processes within unsaturated and saturated zone. Hence a prototype system of Time and Frequency Domain Reflectometry (TDR & FDR) sensors is developed and will be installed, in order to achieve continuous quantitative monitoring of the unsaturated zone through the entire soil column down to significant depths below the SAT basin. Additionally, the system contains two different radar-based sensing systems that will be offering (i) identification of preferential

  15. 40 CFR 97.632 - Monitoring system out-of-control periods.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... Whenever any monitoring system fails to meet the quality-assurance and quality-control requirements or data validation requirements of part 75 of this chapter, data shall be substituted using the applicable missing data procedures in subpart D or appendix D to part 75 of this chapter. (b) Audit decertification...

  16. 40 CFR 97.732 - Monitoring system out-of-control periods.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... Whenever any monitoring system fails to meet the quality-assurance and quality-control requirements or data validation requirements of part 75 of this chapter, data shall be substituted using the applicable missing data procedures in subpart D or appendix D to part 75 of this chapter. (b) Audit decertification...

  17. 40 CFR 97.632 - Monitoring system out-of-control periods.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... Whenever any monitoring system fails to meet the quality-assurance and quality-control requirements or data validation requirements of part 75 of this chapter, data shall be substituted using the applicable missing data procedures in subpart D or appendix D to part 75 of this chapter. (b) Audit decertification...

  18. 40 CFR 97.732 - Monitoring system out-of-control periods.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... Whenever any monitoring system fails to meet the quality-assurance and quality-control requirements or data validation requirements of part 75 of this chapter, data shall be substituted using the applicable missing data procedures in subpart D or appendix D to part 75 of this chapter. (b) Audit decertification...

  19. 40 CFR 97.632 - Monitoring system out-of-control periods.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... Whenever any monitoring system fails to meet the quality-assurance and quality-control requirements or data validation requirements of part 75 of this chapter, data shall be substituted using the applicable missing data procedures in subpart D or appendix D to part 75 of this chapter. (b) Audit decertification...

  20. 40 CFR 97.732 - Monitoring system out-of-control periods.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... Whenever any monitoring system fails to meet the quality-assurance and quality-control requirements or data validation requirements of part 75 of this chapter, data shall be substituted using the applicable missing data procedures in subpart D or appendix D to part 75 of this chapter. (b) Audit decertification...

  1. Monitoring of heavy metals in selected Water Supply Systems in Poland, in relation to current regulations

    NASA Astrophysics Data System (ADS)

    Szuster-Janiaczyk, Agnieszka; Zeuschner, Piotr; Noga, Paweł; Skrzypczak, Marta

    2018-02-01

    The study presents an analysis of water quality monitoring in terms of the content of heavy metals, which is conducted in three independent water supply systems in Poland. The analysis showed that the monitoring of heavy metals isn't reliable - both the quantity of tested water samples and the location of the monitoring points are the problem. The analysis of changes in water quality from raw water to tap water was possible only for one of the analysed systems and indicate a gradual deterioration of water quality, although still within acceptable limits of legal regulations.

  2. Monitoring Air Quality with Leaf Yeasts.

    ERIC Educational Resources Information Center

    Richardson, D. H. S.; And Others

    1985-01-01

    Proposes that leaf yeast serve as quick, inexpensive, and effective techniques for monitoring air quality. Outlines procedures and provides suggestions for data analysis. Includes results from sample school groups who employed this technique. (ML)

  3. Water-quality and hydrogeologic data used to evaluate the effects of farming systems on ground-water quality at the Management Systems Evaluation Area near Princeton,Minnesota, 1991-95

    USGS Publications Warehouse

    Landon, M.K.; Delin, G.N.; Nelson, K.J.; Regan, C.P.; Lamb, J.A.; Larson, S.J.; Capel, P.D.; Anderson, J.L.; Dowdy, R.H.

    1997-01-01

    The Minnesota Management Systems Evaluation Area (MSEA) project was part of a multi-scale, inter-agency initiative to evaluate the effects of agricultural management systems on water quality in the midwest corn belt. The research area was located in the Anoka Sand Plain about 5 kilometers southwest of Princeton, Minnesota. The ground-water-quality monitoring network within and immediately surrounding the research area consisted of 73 observation wells and 25 multiport wells. The primary objectives of the ground-water monitoring program at the Minnesota MSEA were to: (1) determine the effects of three farming systems on ground-water quality, and (2) understand the processes and factors affecting the loading, transport, and fate of agricultural chemicals in ground water at the site. This report presents well construction, geologic, water-level, chemical application, water-quality, and quality-assurance data used to evaluate the effects of farming systems on ground-water quality during 1991-95.

  4. Monitoring the Quality of Medicines: Results from Africa, Asia, and South America

    PubMed Central

    Hajjou, Mustapha; Krech, Laura; Lane-Barlow, Christi; Roth, Lukas; Pribluda, Victor S.; Phanouvong, Souly; El-Hadri, Latifa; Evans, Lawrence; Raymond, Christopher; Yuan, Elaine; Siv, Lang; Vuong, Tuan-Anh; Boateng, Kwasi Poku; Okafor, Regina; Chibwe, Kennedy M.; Lukulay, Patrick H.

    2015-01-01

    Monitoring the quality of medicines plays a crucial role in an integrated medicines quality assurance system. In a publicly available medicines quality database (MQDB), the U.S. Pharmacopeial Convention (USP) reports results of data collected from medicines quality monitoring (MQM) activities spanning the period of 2003–2013 in 17 countries of Africa, Asia, and South America. The MQDB contains information on 15,063 samples collected and tested using Minilab® screening methods and/or pharmacopeial methods. Approximately 71% of the samples reported came from Asia, 23% from Africa, and 6% from South America. The samples collected and tested include mainly antibiotic, antimalarial, and antituberculosis medicines. A total of 848 samples, representing 5.6% of total samples, failed the quality test. The failure proportion per region was 11.5%, 10.4%, and 2.9% for South America, Africa, and Asia, respectively. Eighty-one counterfeit medicines were reported, 86.4% of which were found in Asia and 13.6% in Africa. Additional analysis of the data shows the distribution of poor-quality medicines per region and by therapeutic indication as well as possible trends of counterfeit medicines. PMID:25897073

  5. A decision tree model to estimate the value of information provided by a groundwater quality monitoring network

    NASA Astrophysics Data System (ADS)

    Khader, A. I.; Rosenberg, D. E.; McKee, M.

    2013-05-01

    Groundwater contaminated with nitrate poses a serious health risk to infants when this contaminated water is used for culinary purposes. To avoid this health risk, people need to know whether their culinary water is contaminated or not. Therefore, there is a need to design an effective groundwater monitoring network, acquire information on groundwater conditions, and use acquired information to inform management options. These actions require time, money, and effort. This paper presents a method to estimate the value of information (VOI) provided by a groundwater quality monitoring network located in an aquifer whose water poses a spatially heterogeneous and uncertain health risk. A decision tree model describes the structure of the decision alternatives facing the decision-maker and the expected outcomes from these alternatives. The alternatives include (i) ignore the health risk of nitrate-contaminated water, (ii) switch to alternative water sources such as bottled water, or (iii) implement a previously designed groundwater quality monitoring network that takes into account uncertainties in aquifer properties, contaminant transport processes, and climate (Khader, 2012). The VOI is estimated as the difference between the expected costs of implementing the monitoring network and the lowest-cost uninformed alternative. We illustrate the method for the Eocene Aquifer, West Bank, Palestine, where methemoglobinemia (blue baby syndrome) is the main health problem associated with the principal contaminant nitrate. The expected cost of each alternative is estimated as the weighted sum of the costs and probabilities (likelihoods) associated with the uncertain outcomes resulting from the alternative. Uncertain outcomes include actual nitrate concentrations in the aquifer, concentrations reported by the monitoring system, whether people abide by manager recommendations to use/not use aquifer water, and whether people get sick from drinking contaminated water. Outcome costs

  6. ATLAS Tile Calorimeter calibration and monitoring systems

    NASA Astrophysics Data System (ADS)

    Cortés-González, Arely

    2018-01-01

    The ATLAS Tile Calorimeter is the central section of the hadronic calorimeter of the ATLAS experiment and provides important information for reconstruction of hadrons, jets, hadronic decays of tau leptons and missing transverse energy. This sampling calorimeter uses steel plates as absorber and scintillating tiles as active medium. The light produced by the passage of charged particles is transmitted by wavelength shifting fibres to photomultiplier tubes, located in the outer part of the calorimeter. Neutral particles may also produce a signal after interacting with the material and producing charged particles. The readout is segmented into about 5000 cells, each of them being read out by two photomultipliers in parallel. To calibrate and monitor the stability and performance of each part of the readout chain during the data taking, a set of calibration systems is used. This comprises Cesium radioactive sources, Laser, charge injection elements and an integrator based readout system. Information from all systems allows to monitor and equalise the calorimeter response at each stage of the signal production, from scintillation light to digitisation. Calibration runs are monitored from a data quality perspective and used as a cross-check for physics runs. The data quality efficiency achieved during 2016 was 98.9%. These calibration and stability of the calorimeter reported here show that the TileCal performance is within the design requirements and has given essential contribution to reconstructed objects and physics results.

  7. Wyoming groundwater-quality monitoring network

    USGS Publications Warehouse

    Boughton, Gregory K.

    2011-01-01

    A wide variety of human activities have the potential to contaminate groundwater. In addition, naturally occurring constituents can limit the suitability of groundwater for some uses. The State of Wyoming has established rules and programs to evaluate and protect groundwater quality based on identified uses. The Wyoming Groundwater-Quality Monitoring Network (WGQMN) is a cooperative program between the U.S. Geological Survey (USGS) and the Wyoming Department of Environmental Quality (WDEQ) and was implemented in 2009 to evaluate the water-quality characteristics of the State's groundwater. Representatives from USGS, WDEQ, U.S. Environmental Protection Agency (USEPA), Wyoming Water Development Office, and Wyoming State Engineer's Office formed a steering committee, which meets periodically to evaluate progress and consider modifications to strengthen program objectives. The purpose of this fact sheet is to describe the WGQMN design and objectives, field procedures, and water-quality analyses. USGS groundwater activities in the Greater Green River Basin also are described.

  8. Why do water quality monitoring programs succeed or fail? A qualitative comparative analysis of regulated testing systems in sub-Saharan Africa.

    PubMed

    Peletz, Rachel; Kisiangani, Joyce; Bonham, Mateyo; Ronoh, Patrick; Delaire, Caroline; Kumpel, Emily; Marks, Sara; Khush, Ranjiv

    2018-05-31

    Water quality testing is critical for guiding water safety management and ensuring public health. In many settings, however, water suppliers and surveillance agencies do not meet regulatory requirements for testing frequencies. This study examines the conditions that promote successful water quality monitoring in Africa, with the goal of providing evidence for strengthening regulated water quality testing programs. We compared monitoring programs among 26 regulated water suppliers and surveillance agencies across six African countries. These institutions submitted monthly water quality testing results over 18 months. We also collected qualitative data on the conditions that influenced testing performance via approximately 821 h of semi-structured interviews and observations. Based on our qualitative data, we developed the Water Capacity Rating Diagnostic (WaterCaRD) to establish a scoring framework for evaluating the effects of the following conditions on testing performance: accountability, staffing, program structure, finances, and equipment & services. We summarized the qualitative data into case studies for each of the 26 institutions and then used the case studies to score the institutions against the conditions captured in WaterCaRD. Subsequently, we applied fuzzy-set Qualitative Comparative Analysis (fsQCA) to compare these scores against performance outcomes for water quality testing. We defined the performance outcomes as the proportion of testing Targets Achieved (outcome 1) and Testing Consistency (outcome 2) based on the monthly number of microbial water quality tests conducted by each institution. Our analysis identified motivation & leadership, knowledge, staff retention, and transport as institutional conditions that were necessary for achieving monitoring targets. In addition, equipment, procurement, infrastructure, and enforcement contributed to the pathways that resulted in strong monitoring performance. Our identification of institutional

  9. Earth Observation Data Quality Monitoring and Control: A Case Study of STAR Central Data Repository

    NASA Astrophysics Data System (ADS)

    Han, W.; Jochum, M.

    2017-12-01

    Earth observation data quality is very important for researchers and decision makers involved in weather forecasting, severe weather warning, disaster and emergency response, environmental monitoring, etc. Monitoring and control earth observation data quality, especially accuracy, completeness, and timeliness, is very useful in data management and governance to optimize data flow, discover potential transmission issues, and better connect data providers and users. Taking a centralized near real-time satellite data repository, STAR (Center for Satellite Applications and Research of NOAA) Central Data Repository (SCDR), as an example, this paper describes how to develop new mechanism to verify data integrity, check data completeness, and monitor data latency in an operational data management system. Such quality monitoring and control of large volume satellite data help data providers and managers improve data transmission of near real-time satellite data, enhance its acquisition and management, and overcome performance and management issues to better serve research and development activities.

  10. Automated water monitor system field demonstration test report. Volume 1: Executive summary

    NASA Technical Reports Server (NTRS)

    Brooks, R. L.; Jeffers, E. L.; Perreira, J.; Poel, J. D.; Nibley, D.; Nuss, R. H.

    1981-01-01

    A system that performs water quality monitoring on-line and in real time much as it would be done in a spacecraft, was developed and demonstrated. The system has the capability to determine conformance to high effluent quality standards and to increase the potential for reclamation and reuse of water.

  11. Design of a ground-water-quality monitoring network for the Salinas River basin, California

    USGS Publications Warehouse

    Showalter, P.K.; Akers, J.P.; Swain, L.A.

    1984-01-01

    A regional ground-water quality monitoring network for the entire Salinas River drainage basin was designed to meet the needs of the California State Water Resources Control Board. The project included phase 1--identifying monitoring networks that exist in the region; phase 2--collecting information about the wells in each network; and phase 3--studying the factors--such as geology, land use, hydrology, and geohydrology--that influence the ground-water quality, and designing a regional network. This report is the major product of phase 3. Based on the authors ' understanding of the ground-water-quality monitoring system and input from local offices, an ideal network was designed. The proposed network includes 317 wells and 8 stream-gaging stations. Because limited funds are available to implement the monitoring network, the proposed network is designed to correspond to the ideal network insofar as practicable, and is composed mainly of 214 wells that are already being monitored by a local agency. In areas where network wells are not available, arrangements will be made to add wells to local networks. The data collected by this network will be used to assess the ground-water quality of the entire Salinas River drainage basin. After 2 years of data are collected, the network will be evaluated to test whether it is meeting the network objectives. Subsequent network evaluations will be done very 5 years. (USGS)

  12. Monitoring Welding-Gas Quality

    NASA Technical Reports Server (NTRS)

    Huddleston, Kevin L.

    1988-01-01

    System monitors welding gas to ensure characteristics within predetermined values. Responds to changes that might go unnoticed by human operator and acts quickly to prevent weld defects. Electronic pressure controller employs various amounts of gain, equalization, and compensation to respond to changes in gas-supply pressure. Works in conjuction with pressure/oxygen/moisture monitor.

  13. Performance Evaluation of the United Nations Environment Programme Air Quality Monitoring Unit

    EPA Science Inventory

    A request for technical collaboration between the UNEP and the US EPA resulted in the establishment of a MCRADA. The purpose of this agreement was to evaluate an air quality monitoring system (referred to as the UNEP pod) developed by the UNEP for use in environmental situations ...

  14. Monitoring Quality of Biotherapeutic Products Using Multivariate Data Analysis.

    PubMed

    Rathore, Anurag S; Pathak, Mili; Jain, Renu; Jadaun, Gaurav Pratap Singh

    2016-07-01

    Monitoring the quality of pharmaceutical products is a global challenge, heightened by the implications of letting subquality drugs come to the market on public safety. Regulatory agencies do their due diligence at the time of approval as per their prescribed regulations. However, product quality needs to be monitored post-approval as well to ensure patient safety throughout the product life cycle. This is particularly complicated for biotechnology-based therapeutics where seemingly minor changes in process and/or raw material attributes have been shown to have a significant effect on clinical safety and efficacy of the product. This article provides a perspective on the topic of monitoring the quality of biotech therapeutics. In the backdrop of challenges faced by the regulatory agencies, the potential use of multivariate data analysis as a tool for effective monitoring has been proposed. Case studies using data from several insulin biosimilars have been used to illustrate the key concepts.

  15. Southern California Bight 2003 Regional Monitoring Program: V. water quality

    USGS Publications Warehouse

    Nezlin, Nikolay P.; DiGiacomo, Paul M.; Weisberg, Stephen B.; Diehl, Dario W.; Warrick, Jonathan A.; Mengel, Michael J.; Jones, Burton H.; Reifel, Kristen M.; Johnson, Scott C.; Ohlmann, J. Carter; Washburn, Libe; Terrill, Eric J.

    2007-01-01

    More than $30 million is expended annually on environmental monitoring in the Southern California Bight (SCB), yet only 5% of the Bight is monitored on an ongoing basis. Therefore, environmental managers in the SCB decided to expand their monitoring program and, starting in 1994, decided to conduct periodic regional assessments of ecosystem condition and assess the overall health of the SCB. Sixty-five different organizations collaborated in 2003 to create the third SCB Regional Monitoring Program (Bight '03). Bight '03 was designed to be integrated regional monitoring program that encompasses regulatory, academic, and non-governmental agencies. Bight '03 had three components: Coastal Ecology, Shoreline Microbiology, and Water Quality. This report addresses the purpose, approach, findings, and recommendations from the Water Quality component, which focused on contamination-laden stormwater runoff, in particularly its variability in time and space as well as its short-term ecological impacts. Specifically, the Bight '03 Water Quality component had three primary goals, the first of which was to described the temporal evolution of stormwater plumes produced by the major southern California rivers. Specifically, the study was intended to determine how far offshore the plumes extended, how rapidly they advected, how long before the plumes dispersed and how these properties differed among storms and river systems. The second goal was to describe how the physical properties (e.g., turbidity, temperature, salinity) of the plume related to biogeochemical and ecological properties that are of more direct concern to the water quality management community. Accomplished primarily through ship-based sampling of water quality parameters, this second goal was to describe how far offshore, and for how ;long after the storm, elevated bacterial concentrations, toxicity, and nutrients could be detected. Similar to the fist goal, the study also addressed how these answers differed

  16. 40 CFR 97.532 - Monitoring system out-of-control periods.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... Whenever any monitoring system fails to meet the quality-assurance and quality-control requirements or data validation requirements of part 75 of this chapter, data shall be substituted using the applicable missing data procedures in subpart D or subpart H of, or appendix D or appendix E to, part 75 of this chapter...

  17. 40 CFR 97.532 - Monitoring system out-of-control periods.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... Whenever any monitoring system fails to meet the quality-assurance and quality-control requirements or data validation requirements of part 75 of this chapter, data shall be substituted using the applicable missing data procedures in subpart D or subpart H of, or appendix D or appendix E to, part 75 of this chapter...

  18. 40 CFR 97.532 - Monitoring system out-of-control periods.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... Whenever any monitoring system fails to meet the quality-assurance and quality-control requirements or data validation requirements of part 75 of this chapter, data shall be substituted using the applicable missing data procedures in subpart D or subpart H of, or appendix D or appendix E to, part 75 of this chapter...

  19. Environmental Monitoring Curriculum System and Application-Oriented Training

    ERIC Educational Resources Information Center

    Wang, Jing-Ping; Wang, Xin-Hong

    2016-01-01

    Through building the environmental monitoring curriculum system for application-oriented talents, the comprehensive design and practice were constructed from the syllabus, textbooks, web-based courses, top-quality courses, test paper bank, open laboratory and scientific research etc. The aims are to promote environmental science professional,…

  20. Source water monitoring and biomonitoring systems

    EPA Science Inventory

    Presentation will provide background information on continuous source water monitoring using online toxicity monitors and cover various tools available. Conceptual and practical aspects of source water quality monitoring will be discussed.

  1. Asan medical information system for healthcare quality improvement.

    PubMed

    Ryu, Hyeon Jeong; Kim, Woo Sung; Lee, Jae Ho; Min, Sung Woo; Kim, Sun Ja; Lee, Yong Su; Lee, Young Ha; Nam, Sang Woo; Eo, Gi Seung; Seo, Sook Gyoung; Nam, Mi Hyun

    2010-09-01

    This purpose of this paper is to introduce the status of the Asan Medical Center (AMC) medical information system with respect to healthcare quality improvement. Asan Medical Information System (AMIS) is projected to become a completely electronic and digital information hospital. AMIS has played a role in improving the health care quality based on the following measures: safety, effectiveness, patient-centeredness, timeliness, efficiency, privacy, and security. AMIS CONSISTED OF SEVERAL DISTINCTIVE SYSTEMS: order communication system, electronic medical record, picture archiving communication system, clinical research information system, data warehouse, enterprise resource planning, IT service management system, and disaster recovery system. The most distinctive features of AMIS were the high alert-medication recognition & management system, the integrated and severity stratified alert system, the integrated patient monitoring system, the perioperative diabetic care monitoring and support system, and the clinical indicator management system. AMIS provides IT services for AMC, 7 affiliated hospitals and over 5,000 partners clinics, and was developed to improve healthcare services. The current challenge of AMIS is standard and interoperability. A global health IT strategy is needed to get through the current challenges and to provide new services as needed.

  2. Systematic monitoring and evaluation of M7 scanner performance and data quality

    NASA Technical Reports Server (NTRS)

    Stewart, S.; Christenson, D.; Larsen, L.

    1974-01-01

    An investigation was conducted to provide the information required to maintain data quality of the Michigan M7 Multispectral scanner by systematic checks on specific system performance characteristics. Data processing techniques which use calibration data gathered routinely every mission have been developed to assess current data quality. Significant changes from past data quality are thus identified and attempts made to discover their causes. Procedures for systematic monitoring of scanner data quality are discussed. In the solar reflective region, calculations of Noise Equivalent Change in Radiance on a permission basis are compared to theoretical tape-recorder limits to provide an estimate of overall scanner performance. M7 signal/noise characteristics are examined.

  3. Satellite-based virtual buoy system to monitor coastal water quality

    NASA Astrophysics Data System (ADS)

    Hu, Chuanmin; Barnes, Brian B.; Murch, Brock; Carlson, Paul

    2014-05-01

    There is a pressing need to assess coastal and estuarine water quality state and anomaly events to facilitate coastal management, but such a need is hindered by lack of resources to conduct frequent ship-based or buoy-based measurements. Here, we established a virtual buoy system (VBS) to facilitate satellite data visualization and interpretation of water quality assessment. The VBS is based on a virtual antenna system (VAS) that obtains low-level satellite data and generates higher-level data products using both National Aeronautics and Space Administration standard algorithms and regionally customized algorithms in near real time. The VB stations are predefined and carefully chosen to cover water quality gradients in estuaries and coastal waters, where multiyear time series at monthly and weekly intervals are extracted for the following parameters: sea surface temperature (°C), chlorophyll-a concentration (mg m-3), turbidity (NTU), diffuse light attenuation at 490 nm [Kd(490), m-1] or secchi disk depth (m), absorption coefficient of colored dissolved organic matter (m-1), and bottom available light (%). The time-series data are updated routinely and provided in both ASCII and graphical formats via a user-friendly web interface where all information is available to the user through a simple click. The VAS and VBS also provide necessary infrastructure to implement peer-reviewed regional algorithms to generate and share improved water quality data products with the user community.

  4. Data quality control in eco-environmental monitoring

    NASA Astrophysics Data System (ADS)

    Lu, Chunyan; Wang, Jing

    2007-11-01

    With the development of science and technology, a number of environmental issues, such as sustainable development, climate change, environmental pollution, and land degradation become serious. Greater attention has been attached to environmental protection. The government gradually launched some eco--environmental construction projects. In 1999, China begin to carry out the project of Grain-for-Green in the west, to improve the eco-environment, and it make some good effect, but there are some questions that still can not be answered. How about the new grass or forest? Where are they? How can we do in the future? To answer these questions, the government began to monitor the eco-environment, based on remote sensing technology. Geography information can be attained timely, but the issue of uncertainty has become increasingly recognized, and this uncertainty affects the reliability of applications using the data. This article analyzed the process of eco-environment monitoring, the uncertainty of geography information, and discussed the methods of data quality control. The Spot5 span data and multi-spectral data in 2003(2002) were used, combined with land use survey data at the scale of 1:10,000, topography data at the scale of 1:10,000, and the local Grain-for-Green project map. Also the social and economic data were collected. Eco-environmental monitoring is a process which consists of several steps, such as image geometric correction, image matching, information extraction, and so on. Based on visual and automated method, land information turned to grass and forest from cultivated land was obtained by comparing the information form remote sensing data with the land survey data, and local Grain-for-Green project data, combined with field survey. According to the process, the uncertainty in the process was analyzed. Positional uncertainty, attribute uncertainty, and thematic uncertainty was obvious. Positional uncertainty mainly derived from image geometric correction

  5. Design of a Water Environment Monitoring System Based on Wireless Sensor Networks

    PubMed Central

    Jiang, Peng; Xia, Hongbo; He, Zhiye; Wang, Zheming

    2009-01-01

    A water environmental monitoring system based on a wireless sensor network is proposed. It consists of three parts: data monitoring nodes, data base station and remote monitoring center. This system is suitable for the complex and large-scale water environment monitoring, such as for reservoirs, lakes, rivers, swamps, and shallow or deep groundwaters. This paper is devoted to the explanation and illustration for our new water environment monitoring system design. The system had successfully accomplished the online auto-monitoring of the water temperature and pH value environment of an artificial lake. The system's measurement capacity ranges from 0 to 80 °C for water temperature, with an accuracy of ±0.5 °C; from 0 to 14 on pH value, with an accuracy of ±0.05 pH units. Sensors applicable to different water quality scenarios should be installed at the nodes to meet the monitoring demands for a variety of water environments and to obtain different parameters. The monitoring system thus promises broad applicability prospects. PMID:22454592

  6. National Satellite Forest Monitoring systems for REDD+

    NASA Astrophysics Data System (ADS)

    Jonckheere, I. G.

    2012-12-01

    countries to adapt it to country needs and the training on the TerraAmazon system is a tool to enhance existing capacity on carbon monitoring systems. The support with the National Forest Monitoring System will allow these countries to follow all actions related to the implementation of its national REDD+ policies and measures. The monitoring system will work as a platform to obtain information on their REDD+ results and actions, related directly or indirectly to national REDD+ strategies and may also include actions unrelated to carbon assessment, such as forest law enforcement. With the technical assistance of FAO, INPE and other stakeholders, the countries will set up an autonomous operational forest monitoring system. An initial version and the methodologies of the system for DRC and PNG has been launched in Durban, South Africa during COP 17 and in 2012 Paraguay, Viet Nam and Zambia will be launched in Doha, Qatar at COP 18. The access to high-quality satellite data for these countries is crucial for the set-up.

  7. An Energy Efficient Adaptive Sampling Algorithm in a Sensor Network for Automated Water Quality Monitoring.

    PubMed

    Shu, Tongxin; Xia, Min; Chen, Jiahong; Silva, Clarence de

    2017-11-05

    Power management is crucial in the monitoring of a remote environment, especially when long-term monitoring is needed. Renewable energy sources such as solar and wind may be harvested to sustain a monitoring system. However, without proper power management, equipment within the monitoring system may become nonfunctional and, as a consequence, the data or events captured during the monitoring process will become inaccurate as well. This paper develops and applies a novel adaptive sampling algorithm for power management in the automated monitoring of the quality of water in an extensive and remote aquatic environment. Based on the data collected on line using sensor nodes, a data-driven adaptive sampling algorithm (DDASA) is developed for improving the power efficiency while ensuring the accuracy of sampled data. The developed algorithm is evaluated using two distinct key parameters, which are dissolved oxygen (DO) and turbidity. It is found that by dynamically changing the sampling frequency, the battery lifetime can be effectively prolonged while maintaining a required level of sampling accuracy. According to the simulation results, compared to a fixed sampling rate, approximately 30.66% of the battery energy can be saved for three months of continuous water quality monitoring. Using the same dataset to compare with a traditional adaptive sampling algorithm (ASA), while achieving around the same Normalized Mean Error (NME), DDASA is superior in saving 5.31% more battery energy.

  8. An Energy Efficient Adaptive Sampling Algorithm in a Sensor Network for Automated Water Quality Monitoring

    PubMed Central

    Shu, Tongxin; Xia, Min; Chen, Jiahong; de Silva, Clarence

    2017-01-01

    Power management is crucial in the monitoring of a remote environment, especially when long-term monitoring is needed. Renewable energy sources such as solar and wind may be harvested to sustain a monitoring system. However, without proper power management, equipment within the monitoring system may become nonfunctional and, as a consequence, the data or events captured during the monitoring process will become inaccurate as well. This paper develops and applies a novel adaptive sampling algorithm for power management in the automated monitoring of the quality of water in an extensive and remote aquatic environment. Based on the data collected on line using sensor nodes, a data-driven adaptive sampling algorithm (DDASA) is developed for improving the power efficiency while ensuring the accuracy of sampled data. The developed algorithm is evaluated using two distinct key parameters, which are dissolved oxygen (DO) and turbidity. It is found that by dynamically changing the sampling frequency, the battery lifetime can be effectively prolonged while maintaining a required level of sampling accuracy. According to the simulation results, compared to a fixed sampling rate, approximately 30.66% of the battery energy can be saved for three months of continuous water quality monitoring. Using the same dataset to compare with a traditional adaptive sampling algorithm (ASA), while achieving around the same Normalized Mean Error (NME), DDASA is superior in saving 5.31% more battery energy. PMID:29113087

  9. Feasibility analysis of marine ecological on-line integrated monitoring system

    NASA Astrophysics Data System (ADS)

    Chu, D. Z.; Cao, X.; Zhang, S. W.; Wu, N.; Ma, R.; Zhang, L.; Cao, L.

    2017-08-01

    The in-situ water quality sensors were susceptible to biological attachment. Moreover, sea water corrosion and wave impact damage, and many sensors scattered distribution would cause maintenance inconvenience. The paper proposed a highly integrated marine ecological on-line integrated monitoring system, which can be used inside monitoring station. All sensors were reasonably classified, the similar in series, the overall in parallel. The system composition and workflow were described. In addition, the paper proposed attention issues of the system design and corresponding solutions. Water quality multi-parameters and 5 nutrient salts as the verification index, in-situ and systematic data comparison experiment were carried out. The results showed that the data consistency of nutrient salt, PH and salinity was better. Temperature and dissolved oxygen data trend was consistent, but the data had deviation. Turbidity fluctuated greatly; the chlorophyll trend was similar with it. Aiming at the above phenomena, three points system optimization direction were proposed.

  10. The aquatic real-time monitoring network; in-situ optical sensors for monitoring the nation's water quality

    USGS Publications Warehouse

    Pellerin, Brian A.; Bergamaschi, Brian A.; Murdoch, Peter S.; Downing, Bryan D.; Saraceno, John Franco; Aiken, George R.; Striegl, Robert G.

    2011-01-01

    Floods, hurricanes, and longer-term changes in climate and land use can have profound effects on water quality due to shifts in hydrologic flow paths, water residence time, precipitation patterns, connectivity between rivers and uplands, and many other factors. In order to understand and respond to changes in hydrology and water quality, resource managers and policy makers have a need for accurate and early indicators, as well as the ability to assess possible mechanisms and likely outcomes. In-situ optical sensors-those making continuous measurements of constituents by absorbance or fluorescence properties in the environment at timescales of minutes to years-have a long history in oceanography for developing highly resolved concentrations and fluxes, but are not commonly used in freshwater systems. The United States Geological Survey (USGS) has developed the Aquatic Real-Time Monitoring Network, with high-resolution optical data collection for organic carbon, nutrients, and sediment in large coastal rivers, along with continuous measurements of discharge, water temperature, and dissolved inorganic carbon. The collecting of continuous water-quality data in the Nation?s waterways has revealed temporal trends and spatial patterns in constituents that traditional sampling approaches fail to capture, and will serve a critical role in monitoring, assessment and decision-making in a rapidly changing landscape.

  11. HyperCard Monitor System.

    ERIC Educational Resources Information Center

    Harris, Julian; Maurer, Hermann

    An investigation into high level event monitoring within the scope of a well-known multimedia application, HyperCard--a program on the Macintosh computer, is carried out. A monitoring system is defined as a system which automatically monitors usage of some activity and gathers statistics based on what is has observed. Monitor systems can give the…

  12. [Study on the optimization of monitoring indicators of drinking water quality during health supervision].

    PubMed

    Ye, Bixiong; E, Xueli; Zhang, Lan

    2015-01-01

    To optimize non-regular drinking water quality indices (except Giardia and Cryptosporidium) of urban drinking water. Several methods including drinking water quality exceed the standard, the risk of exceeding standard, the frequency of detecting concentrations below the detection limit, water quality comprehensive index evaluation method, and attribute reduction algorithm of rough set theory were applied, redundancy factor of water quality indicators were eliminated, control factors that play a leading role in drinking water safety were found. Optimization results showed in 62 unconventional water quality monitoring indicators of urban drinking water, 42 water quality indicators could be optimized reduction by comprehensively evaluation combined with attribute reduction of rough set. Optimization of the water quality monitoring indicators and reduction of monitoring indicators and monitoring frequency could ensure the safety of drinking water quality while lowering monitoring costs and reducing monitoring pressure of the sanitation supervision departments.

  13. Field assessment of the Village Green Project: an autonomous community air quality monitoring system.

    PubMed

    Jiao, Wan; Hagler, Gayle S W; Williams, Ronald W; Sharpe, Robert N; Weinstock, Lewis; Rice, Joann

    2015-05-19

    Continuous, long-term, and time-resolved measurement of outdoor air pollution has been limited by logistical hurdles and resource constraints. Measuring air pollution in more places is desired to address community concerns regarding local air quality impacts related to proximate sources, to provide data in areas lacking regional air monitoring altogether, or to support environmental awareness and education. This study integrated commercially available technologies to create the Village Green Project (VGP), a durable, solar-powered air monitoring park bench that measures real-time ozone, PM2.5, and meteorological parameters. The data are wirelessly transmitted via cellular modem to a server, where automated quality checks take place before data are provided to the public nearly instantaneously. Over 5500 h of data were successfully collected during the first ten months of pilot testing in Durham, North Carolina, with about 13 days (5.5%) of downtime because of low battery power. Additional data loss (4-14% depending on the measurement) was caused by infrequent wireless communication interruptions and instrument maintenance. The 94.5% operational time via solar power was within 1.5% of engineering calculations using historical solar data for the location. The performance of the VGP was evaluated by comparing the data to nearby air monitoring stations operating federal equivalent methods (FEM), which exhibited good agreement with the nearest benchmark FEMs for hourly ozone (r(2) = 0.79) and PM2.5 (r(2) = 0.76).

  14. Grain quality inspection system

    NASA Technical Reports Server (NTRS)

    Flood, C. A., Jr.; Singletow, D. P.; James, S. N.

    1979-01-01

    A review of grain quality indicators and measurement methods was conducted in order to assess the feasibility of using remote sensing technology to develop a continuous monitoring system for use during grain transfer operations. Most detection methods were found to be too slow or too expensive to be incorporated into the normal inspection procedure of a grain elevator on a continuous basis. Two indicators, moisture content and broken corn and foreign material, show potential for automation and are of an economic value. A microprocessor based system which utilizes commercially available electronic moisture meter was developed and tested. A method for automating BCFM measurement is described. A complete system description is presented along with performance test results.

  15. Santa Margarita Estuary Water Quality Monitoring Data

    DTIC Science & Technology

    2018-02-01

    ADMINISTRATIVE INFORMATION The work described in this report was performed for the Water Quality Section of the Environmental Security Marine Corps Base...water quality model calibration given interest and the necessary resources. The dataset should also inform the stakeholders and Regional Board on...period. Several additional ancillary datasets were collected during the monitoring timeframe that provide key information though they were not collected

  16. Application of ion-sensitive sensors in water quality monitoring.

    PubMed

    Winkler, S; Rieger, L; Saracevic, E; Pressl, A; Gruber, G

    2004-01-01

    Within the last years a trend towards in-situ monitoring can be observed, i.e. most new sensors for water quality monitoring are designed for direct installation in the medium, compact in size and use measurement principles which minimise maintenance demand. Ion-sensitive sensors (Ion-Sensitive-Electrode--ISE) are based on a well known measurement principle and recently some manufacturers have released probe types which are specially adapted for application in water quality monitoring. The function principle of ISE-sensors, their advantages, limitations and the different methods for sensor calibration are described. Experiences with ISE-sensors from applications in sewer networks, at different sampling points within wastewater treatment plants and for surface water monitoring are reported. An estimation of investment and operation costs in comparison to other sensor types is given.

  17. Feasibility study of imaging spectroscopy to monitor the quality of online welding.

    PubMed

    Mirapeix, Jesús; García-Allende, P Beatriz; Cobo, Adolfo; Conde, Olga M; López-Higuera, José M

    2009-08-20

    An online welding quality system based on the use of imaging spectroscopy is proposed and discussed. Plasma optical spectroscopy has already been successfully applied in this context by establishing a direct correlation between some spectroscopic parameters, e.g., the plasma electronic temperature and the resulting seam quality. Given that the use of the so-called hyperspectral devices provides both spatial and spectral information, we propose their use for the particular case of arc welding quality monitoring in an attempt to determine whether this technique would be suitable for this industrial situation. Experimental welding tests are presented, and the ability of the proposed solution to identify simulated defects is proved. Detailed spatial analyses suggest that this additional dimension can be used to improve the performance of the entire system.

  18. The study of surgical image quality evaluation system by subjective quality factor method

    NASA Astrophysics Data System (ADS)

    Zhang, Jian J.; Xuan, Jason R.; Yang, Xirong; Yu, Honggang; Koullick, Edouard

    2016-03-01

    GreenLightTM procedure is an effective and economical way of treatment of benign prostate hyperplasia (BPH); there are almost a million of patients treated with GreenLightTM worldwide. During the surgical procedure, the surgeon or physician will rely on the monitoring video system to survey and confirm the surgical progress. There are a few obstructions that could greatly affect the image quality of the monitoring video, like laser glare by the tissue and body fluid, air bubbles and debris generated by tissue evaporation, and bleeding, just to name a few. In order to improve the physician's visual experience of a laser surgical procedure, the system performance parameter related to image quality needs to be well defined. However, since image quality is the integrated set of perceptions of the overall degree of excellence of an image, or in other words, image quality is the perceptually weighted combination of significant attributes (contrast, graininess …) of an image when considered in its marketplace or application, there is no standard definition on overall image or video quality especially for the no-reference case (without a standard chart as reference). In this study, Subjective Quality Factor (SQF) and acutance are used for no-reference image quality evaluation. Basic image quality parameters, like sharpness, color accuracy, size of obstruction and transmission of obstruction, are used as subparameter to define the rating scale for image quality evaluation or comparison. Sample image groups were evaluated by human observers according to the rating scale. Surveys of physician groups were also conducted with lab generated sample videos. The study shows that human subjective perception is a trustworthy way of image quality evaluation. More systematic investigation on the relationship between video quality and image quality of each frame will be conducted as a future study.

  19. [Research advances in water quality monitoring technology based on UV-Vis spectrum analysis].

    PubMed

    Wei, Kang-Lin; Wen, Zhi-yu; Wu, Xin; Zhang, Zhong-Wei; Zeng, Tian-Ling

    2011-04-01

    The application of spectral analysis to water quality monitoring is an important developing trend in the field of modern environment monitoring technology. The principle and characteristic of water quality monitoring technology based on UV-Vis spectrum analysis are briefly reviewed. And the research status and advances are introduced from two aspects, on-line monitoring and in-situ monitoring. Moreover, the existent key technical problems are put forward. Finally, the technology trends of multi-parameter water quality monitoring microsystem and microsystem networks based on microspectrometer are prospected, which has certain reference value for the research and development of environmental monitoring technology and modern scientific instrument in the authors' country.

  20. Parental sleep quality and continuous glucose monitoring system use in children with type 1 diabetes.

    PubMed

    Landau, Z; Rachmiel, M; Pinhas-Hamiel, O; Boaz, M; Bar-Dayan, Y; Wainstein, J; Tauman, R

    2014-01-01

    To compare sleep quality and sleep-wake patterns in parents of children with type 1 diabetes before routine use of the continuous glucose monitoring system (CGMS) and while using it. Thirteen parents completed the Pittsburg Sleep Quality Index (PSQI), a 7-day sleep diary, and wore an actigraph (a wristwatch-size motion detector) during the night for 1 week before pediatric use of CGMS and 4-8 weeks after initiating routine use of the CGMS. Mean age of parents (ten mothers, three fathers) was 39 (range 32-47) years; mean age of children was 9.3 years (range 5.5-16.5 years); mean disease duration was 3.4 (range 0.6-11.2) years. PSQI total score demonstrated similar quality of sleep with and without use of the CGMS (4.6 and 4.9, respectively, p = 0.45). Six of the 13 parents reported severe sleep problems (PSQI ≥ 5) with and without the CGMS. The sleep diary indicated a greater number of awakening episodes during CGMS use than without the CGMS (1.6 and 1, respectively, p = 0.03), and actigraphy documented an increase in the number of wake bouts (22.9 and 19.7, p = 0.03) as well as in total wake time (48.3 and 42.2 min, p = 0.03) during CGMS use as compared with the period prior to CGMS use. Although self-perception of sleep quality remained unchanged, CGMS use appeared to affect actual parental sleep continuity somewhat negatively. This should be made clear to parents who may hold expectations of improvement in sleep quality following initiation of CGMS use.

  1. Development, application, and sensitivity analysis of a water quality index for drinking water management in small systems.

    PubMed

    Scheili, A; Rodriguez, Manuel J; Sadiq, R

    2015-11-01

    The aim of this study was to produce a drinking water assessment tool for operators of small distribution systems. A drinking water quality index (DWQI) was developed and applied to small systems based on the water quality index of the Canadian Council of Ministers of Environment. The drinking water quality index was adapted to specific needs by creating four drinking water quality scenarios. First, the temporal and spatial dimensions of drinking water quality variability were taken into account. The DWQI was designed to express global drinking water quality according to different monitoring frequencies. Daily, monthly, and seasonal assessment was also considered. With the data made available, it was possible to use the index as a spatial monitoring tool and express water quality in different points in the distribution system. Moreover, adjustments were made to prioritize the type of contaminant to monitor. For instance, monitoring contaminants with acute health effects led to a scenario based on daily measures, including easily accessible and affordable water quality parameters. On the other hand, contaminants with chronic effects, especially disinfection by-products, were considered in a seasonal monitoring scenario where disinfection by-product reference values were redefined according to their seasonal variability. A sensitivity analysis was also carried out to validate the index. Globally, the DWQI developed is adapted to the needs of small systems. In fact, expressing drinking water quality using the DWQI contributes to the identification of problematic periods and segments in the distribution system. Further work may include this index in the development of a customized decision-making tool for small-system operators and managers.

  2. Video Monitoring a Simulation-Based Quality Improvement Program in Bihar, India.

    PubMed

    Dyer, Jessica; Spindler, Hilary; Christmas, Amelia; Shah, Malay Bharat; Morgan, Melissa; Cohen, Susanna R; Sterne, Jason; Mahapatra, Tanmay; Walker, Dilys

    2018-04-01

    Simulation-based training has become an accepted clinical training andragogy in high-resource settings with its use increasing in low-resource settings. Video recordings of simulated scenarios are commonly used by facilitators. Beyond using the videos during debrief sessions, researchers can also analyze the simulation videos to quantify technical and nontechnical skills during simulated scenarios over time. Little is known about the feasibility and use of large-scale systems to video record and analyze simulation and debriefing data for monitoring and evaluation in low-resource settings. This manuscript describes the process of designing and implementing a large-scale video monitoring system. Mentees and Mentors were consented and all simulations and debriefs conducted at 320 Primary Health Centers (PHCs) were video recorded. The system design, number of video recordings, and inter-rater reliability of the coded videos were assessed. The final dataset included a total of 11,278 videos. Overall, a total of 2,124 simulation videos were coded and 183 (12%) were blindly double-coded. For the double-coded sample, the average inter-rater reliability (IRR) scores were 80% for nontechnical skills, and 94% for clinical technical skills. Among 4,450 long debrief videos received, 216 were selected for coding and all were double-coded. Data quality of simulation videos was found to be very good in terms of recorded instances of "unable to see" and "unable to hear" in Phases 1 and 2. This study demonstrates that video monitoring systems can be effectively implemented at scale in resource limited settings. Further, video monitoring systems can play several vital roles within program implementation, including monitoring and evaluation, provision of actionable feedback to program implementers, and assurance of program fidelity.

  3. ON-LINE TOXICITY MONITORS AND WATERSHED EARLY WARNING SYSTEMS

    EPA Science Inventory

    A Water Quality Early Warning System using On-line Toxicity Monitors (OTMs) has been deployed in the East Fork of the Little Miami River, Clermont County, OH. Living organisms have long been used to determine the toxicity of environmental samples. With advancements in electronic ...

  4. Electronic Monitoring Systems to Assess Urinary Incontinence: A Health Technology Assessment

    PubMed Central

    Nevis, Immaculate; Kabali, Conrad; Anh Tu, Hong; Ekanayake, Samanthika; Mistry, Jigna; Wells, David; Ali, Arshia; Walter, Melissa; Higgins, Caroline

    2018-01-01

    Background Urinary incontinence is involuntary leakage of urine and can affect people of all ages. Incidence rises as people age, often because of reduced mobility or conditions affecting the nervous system, such as dementia and stroke. Urinary incontinence can be a distressing condition and can harm a person's physical, financial, social, and emotional well-being. People with urinary incontinence are susceptible to skin irritation, pressure sores, and urinary tract infections. Urinary incontinence is also associated with an increased risk of falls in older adults. This health technology assessment examined the effectiveness of, budget impact of, and patient values and preferences about electronic monitoring systems to assess urinary incontinence for residents of long-term care homes or geriatric hospital inpatients with complex conditions. Methods A clinical evidence review of the published clinical literature was conducted to June 9, 2017. Critical appraisal of the clinical evidence included assessment of risk of bias and the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) Working Group criteria to reflect the certainty of the evidence. We calculated the funding required for an electronic urinary incontinence monitoring system in the first year of implementation (when facilities would buy the systems) and in subsequent years. We interviewed six people with urinary incontinence and two caregivers, who described ways urinary incontinence affected daily life. Results We included one observational study in the clinical review. Most of the 31 participants in the observational study were female (78%) and required high levels of care, primarily because of cognitive impairment. The quality of evidence for all outcomes was very low owing to potential risk of bias and indirectness. We are consequently uncertain about how electronic monitoring systems affect management of urinary incontinence. For patients living in long-term care homes who are

  5. Electronic Monitoring Systems to Assess Urinary Incontinence: A Health Technology Assessment.

    PubMed

    2018-01-01

    Urinary incontinence is involuntary leakage of urine and can affect people of all ages. Incidence rises as people age, often because of reduced mobility or conditions affecting the nervous system, such as dementia and stroke. Urinary incontinence can be a distressing condition and can harm a person's physical, financial, social, and emotional well-being. People with urinary incontinence are susceptible to skin irritation, pressure sores, and urinary tract infections. Urinary incontinence is also associated with an increased risk of falls in older adults.This health technology assessment examined the effectiveness of, budget impact of, and patient values and preferences about electronic monitoring systems to assess urinary incontinence for residents of long-term care homes or geriatric hospital inpatients with complex conditions. A clinical evidence review of the published clinical literature was conducted to June 9, 2017. Critical appraisal of the clinical evidence included assessment of risk of bias and the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) Working Group criteria to reflect the certainty of the evidence.We calculated the funding required for an electronic urinary incontinence monitoring system in the first year of implementation (when facilities would buy the systems) and in subsequent years.We interviewed six people with urinary incontinence and two caregivers, who described ways urinary incontinence affected daily life. We included one observational study in the clinical review. Most of the 31 participants in the observational study were female (78%) and required high levels of care, primarily because of cognitive impairment. The quality of evidence for all outcomes was very low owing to potential risk of bias and indirectness. We are consequently uncertain about how electronic monitoring systems affect management of urinary incontinence.For patients living in long-term care homes who are eligible for the technology, we

  6. Inductive System Health Monitoring

    NASA Technical Reports Server (NTRS)

    Iverson, David L.

    2004-01-01

    The Inductive Monitoring System (IMS) software was developed to provide a technique to automatically produce health monitoring knowledge bases for systems that are either difficult to model (simulate) with a computer or which require computer models that are too complex to use for real time monitoring. IMS uses nominal data sets collected either directly from the system or from simulations to build a knowledge base that can be used to detect anomalous behavior in the system. Machine learning and data mining techniques are used to characterize typical system behavior by extracting general classes of nominal data from archived data sets. IMS is able to monitor the system by comparing real time operational data with these classes. We present a description of learning and monitoring method used by IMS and summarize some recent IMS results.

  7. Development of a Real-Time Environmental Monitoring System, Life Cycle Assessment Systems, and Pollution Prevention Programs

    NASA Technical Reports Server (NTRS)

    Kocher, Walter M.

    2003-01-01

    Pollution prevention (P2) opportunities and Greening the Government (GtG) activities, including the development of the Real-Time Environmental Monitoring System (RTEMS), are currently under development at the NASA Glenn Research Center. The RTEMS project entails the ongoing development of a monitoring system which includes sensors, instruments, computer hardware and software, plus a data telemetry system.Professor Kocher has been directing the RTEMS project for more than 3 years, and the implementation of the prototype system at GRC will be a major portion of his summer effort. This prototype will provide mulitmedia environmental monitoring and control capabilities, although water quality and air emissions will be the immediate issues addressed this summer. Applications beyond those currently identified for environmental purposes will also be explored.

  8. The design of the intelligent monitoring system for dam safety

    NASA Astrophysics Data System (ADS)

    Yuan, Chun-qiao; Jiang, Chen-guang; Wang, Guo-hui

    2008-12-01

    Being a vital manmade water-control structure, a dam plays a very important role in the living and production of human being. To make a dam run safely, the best design and the superior construction quality are paramount; moreover, with working periods increasing, various dynamic, alternative and bad loads generate little by little various distortions on the dam structure inevitably, which shall lead to potential safety problems or further a disaster (dam burst). There are many signs before the occurrence of a dam accident, so the timely and effective surveying on the distortion of a dam is important. On the basis of the cause supra, two intelligent (automatic) monitoring systems about the dam's safety based on the RTK-GPS technology and the measuring robot has been developed. The basic principle, monitoring method and monitoring process of these two intelligent (automatic) monitoring systems are introduced. It presents examples of monitor and puts forward the basic rule of dam warning based on data of actual monitor.

  9. 40 CFR Appendix A to Part 58 - Quality Assurance Requirements for SLAMS, SPMs and PSD Air Monitoring

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... quality system in terms of the organizational structure, functional responsibilities of management and... more stringent requirements. Monitoring organizations may, based on their quality objectives, develop... infrequent work with EPA funds may combine the QMP with the QAPP based on negotiations with the funding...

  10. Resilient monitoring systems: architecture, design, and application to boiler/turbine plant.

    PubMed

    Garcia, Humberto E; Lin, Wen-Chiao; Meerkov, Semyon M; Ravichandran, Maruthi T

    2014-11-01

    Resilient monitoring systems, considered in this paper, are sensor networks that degrade gracefully under malicious attacks on their sensors, causing them to project misleading information. The goal of this paper is to design, analyze, and evaluate the performance of a resilient monitoring system intended to monitor plant conditions (normal or anomalous). The architecture developed consists of four layers: data quality assessment, process variable assessment, plant condition assessment, and sensor network adaptation. Each of these layers is analyzed by either analytical or numerical tools. The performance of the overall system is evaluated using a simplified boiler/turbine plant. The measure of resiliency is quantified based on the Kullback-Leibler divergence and shown to be sufficiently high in all scenarios considered.

  11. Northern Great Plains Network water quality monitoring design for tributaries to the Missouri National Recreational River

    USGS Publications Warehouse

    Rowe, Barbara L.; Wilson, Stephen K.; Yager, Lisa; Wilson, Marcia H.

    2013-01-01

    The National Park Service (NPS) organized more than 270 parks with important natural resources into 32 ecoregional networks to conduct Inventory and Monitoring (I&M) activities for assessment of natural resources within park units. The Missouri National Recreational River (NRR) is among the 13 parks in the NPS Northern Great Plain Network (NGPN). Park managers and NGPN staff identified surface water resources as a high priority vital sign to monitor in park units. The objectives for the Missouri NRR water quality sampling design are to (1) assess the current status and long-term trends of select water quality parameters; and (2) document trends in streamflow at high-priority stream systems. Due to the large size of the Missouri River main stem, the NGPN water quality design for the Missouri NRR focuses on wadeable tributaries within the park unit. To correlate with the NGPN water quality protocols, monitoring of the Missouri NRR consists of measurement of field core parameters including dissolved oxygen, pH, specific conductance, and temperature; and streamflow. The purpose of this document is to discuss factors examined for selection of water quality monitoring on segments of the Missouri River tributaries within the Missouri NRR.Awareness of the complex history of the Missouri NRR aids in the current understanding and direction for designing a monitoring plan. Historical and current monitoring data from agencies and entities were examined to assess potential NGPN monitoring sites. In addition, the U.S. Environmental Protection Agency 303(d) list was examined for the impaired segments on tributaries to the Missouri River main stem. Because major tributaries integrate water quality effects from complex combinations of land use and environmental settings within contributing areas, a 20-mile buffer of the Missouri NRR was used to establish environmental settings that may impact the water quality of tributaries that feed the Missouri River main stem. For selection of

  12. A systems approach to modeling Community-Based Environmental Monitoring: a case of participatory water quality monitoring in rural Mexico.

    PubMed

    Burgos, Ana; Páez, Rosaura; Carmona, Estela; Rivas, Hilda

    2013-12-01

    Community-Based Environmental Monitoring (CBM) is a social practice that makes a valuable contribution to environmental management and construction of active societies for sustainable future. However, its documentation and analysis show deficiencies that hinder contrast and comparison of processes and effects. Based on systems approach, this article presents a model of CBM to orient assessment of programs, with heuristic or practical goals. In a focal level, the model comprises three components, the social subject, the object of monitoring, and the means of action, and five processes, data management, social learning, assimilation/decision making, direct action, and linking. Emergent properties were also identified in the focal and suprafocal levels considering community self-organization, response capacity, and autonomy for environmental management. The model was applied to the assessment of a CBM program of water quality implemented in rural areas in Mexico. Attributes and variables (indicators) for components, processes, and emergent properties were selected to measure changes that emerged since the program implementation. The assessment of the first 3 years (2010-2012) detected changes that indicated movement towards the expected results, but it revealed also the need to adjust the intervention strategy and procedures. Components and processes of the model reflected relevant aspects of the CBM in real world. The component called means of action as a key element to transit "from the data to the action." The CBM model offered a conceptual framework with advantages to understand CBM as a socioecological event and to strengthen its implementation under different conditions and contexts.

  13. Overview of the new National Near-Road Air Quality Monitoring Network

    EPA Science Inventory

    In 2010, EPA promulgated new National Ambient Air Quality Standards (NAAQS) for nitrogen dioxide (NO2). As part of this new NAAQS, EPA required the establishment of a national near-road air quality monitoring network. This network will consist of one NO2 near-road monitoring st...

  14. The avian respiratory system: a unique model for studies of respiratory toxicosis and for monitoring air quality.

    PubMed Central

    Brown, R E; Brain, J D; Wang, N

    1997-01-01

    There are many distinct differences (morphologic, physiologic, and mechanical) between the bird's lung-air-sac respiratory system and the mammalian bronchoalveolar lung. In this paper, we review the physiology of the avian respiratory system with attention to those mechanisms that may lead to significantly different results, relative to those in mammals, following exposure to toxic gases and airborne particulates. We suggest that these differences can be productively exploited to further our understanding of the basic mechanisms of inhalant toxicology (gases and particulates). The large mass-specific gas uptake by the avian respiratory system, at rest and especially during exercise, could be exploited as a sensitive monitor of air quality. Birds have much to offer in our understanding of respiratory toxicology, but that expectation can only be realized by investigating, in a wide variety of avian taxa, the pathophysiologic interactions of a broad range of inhaled toxicants on the bird's unique respiratory system. Images p188-a Figure 1. Figure 2. Figure 3. Figure 4. Figure 5. A Figure 5. B Figure 5. C Figure 6. Figure 7. Figure 8. PMID:9105794

  15. Groundwater-quality and quality-control data for two monitoring wells near Pavillion, Wyoming, April and May 2012

    USGS Publications Warehouse

    Wright, Peter R.; McMahon, Peter B.; Mueller, David K.; Clark, Melanie L.

    2012-01-01

    In June 2010, the U.S. Environmental Protection Agency installed two deep monitoring wells (MW01 and MW02) near Pavillion, Wyoming, to study groundwater quality. During April and May 2012, the U.S Geological Survey, in cooperation with the Wyoming Department of Environmental Quality, collected groundwater-quality data and quality-control data from monitoring well MW01 and, following well redevelopment, quality-control data for monitoring well MW02. Two groundwater-quality samples were collected from well MW01—one sample was collected after purging about 1.5 borehole volumes, and a second sample was collected after purging 3 borehole volumes. Both samples were collected and processed using methods designed to minimize atmospheric contamination or changes to water chemistry. Groundwater-quality samples were analyzed for field water-quality properties (water temperature, pH, specific conductance, dissolved oxygen, oxidation potential); inorganic constituents including naturally occurring radioactive compounds (radon, radium-226 and radium-228); organic constituents; dissolved gasses; stable isotopes of methane, water, and dissolved inorganic carbon; and environmental tracers (carbon-14, chlorofluorocarbons, sulfur hexafluoride, tritium, helium, neon, argon, krypton, xenon, and the ratio of helium-3 to helium-4). Quality-control sample results associated with well MW01 were evaluated to determine the extent to which environmental sample analytical results were affected by bias and to evaluate the variability inherent to sample collection and laboratory analyses. Field documentation, environmental data, and quality-control data for activities that occurred at the two monitoring wells during April and May 2012 are presented.

  16. The Satellite based Monitoring Initiative for Regional Air quality (SAMIRA): Project summary and first results

    NASA Astrophysics Data System (ADS)

    Schneider, Philipp; Stebel, Kerstin; Ajtai, Nicolae; Diamandi, Andrei; Horalek, Jan; Nemuc, Anca; Stachlewska, Iwona; Zehner, Claus

    2017-04-01

    -resolution satellite products of air quality with the help of high-resolution model information. This will add value to existing earth observation products of air quality by bringing them to spatial scales that are more in line with what is generally required for studying urban and regional scale air quality. In a fifth activity, we implement robust and independent validation schemes for evaluating the quality of the generated products. Finally, in a sixth activity the consortium is working towards a pre-operational system for improved PM forecasts using observational (in situ and satellite) data assimilation. SAMIRA aims to maximize project benefits by liaison with national and regional environmental protection agencies and health institutions, as well as related ESA and European initiatives such as the Copernicus Atmosphere Monitoring Service (CAMS).

  17. Hydrogeology and groundwater quality at monitoring wells installed for the Tunnel and Reservoir Plan System and nearby water-supply wells, Cook County, Illinois, 1995–2013

    USGS Publications Warehouse

    Kay, Robert T.

    2016-04-04

    Groundwater-quality data collected from 1995 through 2013 from 106 monitoring wells open to the base of the Silurian aquifer surrounding the Tunnel and Reservoir Plan (TARP) System in Cook County, Illinois, were analyzed by the U.S. Geological Survey, in cooperation with the Metropolitan Water Reclamation District of Greater Chicago, to assess the efficacy of the monitoring network and the effects of water movement from the tunnel system to the surrounding aquifer. Groundwater from the Silurian aquifer typically drains to the tunnel system so that analyte concentrations in most of the samples from most of the monitoring wells primarily reflect the concentration of the analyte in the nearby Silurian aquifer. Water quality in the Silurian aquifer is spatially variable because of a variety of natural and non-TARP anthropogenic processes. Therefore, the trends in analyte values at a given well from 1995 through 2013 are primarily a reflection of the spatial variation in the value of the analyte in groundwater within that part of the Silurian aquifer draining to the tunnels. Intermittent drainage of combined sewer flow from the tunnel system to the Silurian aquifer when flow in the tunnel systemis greater than 80 million gallons per day may affect water quality in some nearby monitoring wells. Intermittent drainage of combined sewer flow from the tunnel system to the Silurian aquifer appears to affect the values of electrical conductivity, hardness, sulfate, chloride, dissolved organic carbon, ammonia, and fecal coliform in samples from many wells but typically during less than 5 percent of the sampling events. Drainage of combined sewer flow into the aquifer is most prevalent in the downstream parts of the tunnel systems because of the hydraulic pressures elevated above background values and long residence time of combined sewer flow in those areas. Elevated values of the analytes emplaced during intermittent migration of combined sewer flow into the Silurian aquifer

  18. Atmospheric Monitoring Strategy for Ground Testing of Closed Ecological Life Support Systems

    NASA Technical Reports Server (NTRS)

    Feighery, John; Cavenall, Ivan; Knight, Amanda

    2004-01-01

    This paper reviews the evolution and current state of atmospheric monitoring on the International Space Station to provide context from which we can imagine a more advanced and integrated system. The unique environmental hazards of human space flight are identified and categorized into groups, taking into consideration the time required for the hazard to become a threat to human health or performance. The key functions of a comprehensive monitoring strategy for a closed ecological life support system are derived from past experience and a survey of currently available technologies for monitoring air quality. Finally, a system architecture is developed incorporating the lessons learned from ISS and other analogous closed life support systems. The paper concludes by presenting recommendations on how to proceed with requirements definition and conceptual design of an air monitoring system for exploration missions.

  19. Study on an agricultural environment monitoring server system using Wireless Sensor Networks.

    PubMed

    Hwang, Jeonghwan; Shin, Changsun; Yoe, Hyun

    2010-01-01

    This paper proposes an agricultural environment monitoring server system for monitoring information concerning an outdoors agricultural production environment utilizing Wireless Sensor Network (WSN) technology. The proposed agricultural environment monitoring server system collects environmental and soil information on the outdoors through WSN-based environmental and soil sensors, collects image information through CCTVs, and collects location information using GPS modules. This collected information is converted into a database through the agricultural environment monitoring server consisting of a sensor manager, which manages information collected from the WSN sensors, an image information manager, which manages image information collected from CCTVs, and a GPS manager, which processes location information of the agricultural environment monitoring server system, and provides it to producers. In addition, a solar cell-based power supply is implemented for the server system so that it could be used in agricultural environments with insufficient power infrastructure. This agricultural environment monitoring server system could even monitor the environmental information on the outdoors remotely, and it could be expected that the use of such a system could contribute to increasing crop yields and improving quality in the agricultural field by supporting the decision making of crop producers through analysis of the collected information.

  20. Design and operation of a low-cost and compact autonomous buoy system for use in coastal aquaculture and water quality monitoring.

    PubMed

    Schmidt, Wiebke; Raymond, David; Parish, David; Ashton, Ian G C; Miller, Peter I; Campos, Carlos J A; Shutler, Jamie D

    2018-01-01

    The need to ensure future food security and issues of varying estuarine water quality is driving the expansion of aquaculture into near-shore coastal waters. It is prudent to fully evaluate new or proposed aquaculture sites, prior to any substantial financial investment in infrastructure and staffing. Measurements of water temperature, salinity and dissolved oxygen can be used to gain insight into the physical, chemical and biological water quality conditions within a farm site, towards identifying its suitability for farming, both for the stock species of interest and for assessing the potential risk from harmful or toxic algae. The latter can cause closure of shellfish harvesting. Unfortunately, commercial scientific monitoring systems can be cost prohibitive for small organisations and companies to purchase and operate. Here we describe the design, construction and deployment of a low cost (<£ 5000) monitoring buoy suitable for use within a near-shore aquaculture farm or bathing waters. The mooring includes a suite of sensors designed for supporting and understanding variations in near-shore physical, chemical and biological water quality. The system has been designed so that it can be operated and maintained by non-scientific staff, whilst still providing good quality scientific data. Data collected from two deployments totalling 14 months, one in a coastal bay location, another in an estuary, have illustrated the robust design and provided insight into the suitability of these sites for aquaculture and the potential occurrence of a toxin causing algae ( Dinophysis spp.). The instruments maintained good accuracy during the deployments when compared to independent in situ measurements (e.g. RMSE 0.13-0.16 °C, bias 0.03-0.08 °C) enabling stratification and biological features to be identified, along with confirming that the waters were suitable for mussel ( Mytilus spp.) and lobster ( Homarus gammarus ) aquaculture, whilst sites showed conditions agreeable

  1. Pervasive mobile healthcare systems for chronic disease monitoring.

    PubMed

    Huzooree, Geshwaree; Kumar Khedo, Kavi; Joonas, Noorjehan

    2017-05-01

    Pervasive mobile healthcare system has the potential to improve healthcare and the quality of life of chronic disease patients through continuous monitoring. Recently, many articles related to pervasive mobile healthcare system focusing on health monitoring using wireless technologies have been published. The main aim of this review is to evaluate the state-of-the-art pervasive mobile healthcare systems to identify major technical requirements and design challenges associated with the realization of a pervasive mobile healthcare system. A systematic literature review was conducted over IEEE Xplore Digital Library to evaluate 20 pervasive mobile healthcare systems out of 683 articles from 2011 to 2016. The classification of the pervasive mobile healthcare systems and other important factors are discussed. Potential opportunities and challenges are pointed out for the further deployment of effective pervasive mobile healthcare systems. This article helps researchers in health informatics to have a holistic view toward understanding pervasive mobile healthcare systems and points out new technological trends and design challenges that researchers have to consider when designing such systems for better adoption, usability, and seamless integration.

  2. Quality of the ophthalmological service to outpatients of the public and private healthcare systems.

    PubMed

    Hercos, Benigno Vicente Santos; Berezovsky, Adriana

    2017-01-01

    To compare perceptions of the quality of ophthalmological services offered to outpatients from the public healthcare system to those from the private healthcare system, and to determine which measures are seen as necessary and a priority for improving the quality of care. This was a prospective observational study on 200 patients, 101 and 99 of whom were from the public and private healthcare systems, respectively. All patients underwent an ophthalmological examination at an ophthalmology hospital in Belo Horizonte, Minas Gerais, Brazil. Personal interviews were conducted using two structured questionnaires adapted from the modified SERVQUAL scale. Overall, patients from the private healthcare system were significantly more dissatisfied than those from the public healthcare system. In both systems, reliability was considered to be the most important determinant of quality, and it presented the highest level of dissatisfaction. Satisfaction with the public healthcare system was significantly greater than that with the private healthcare system in terms of the tangibles, reliability, responsiveness, and assurance determinants of the SERVQUAL scale. Institutions must plan, execute, evaluate, and monitor measures that seek to improve the overall patient satisfaction with the quality of services provided, particularly in the private healthcare system, and special attention must be paid to reliability in both healthcare systems. The identification and monitoring of the quality of healthcare services through the periodic use of the SERVQUAL scale may provide healthcare managers with information so that they can identify, plan, and monitor necessary and priority measures. This could be a key strategy for improving the quality of outpatient health services in the public and private systems.

  3. Scandinavian systems monitoring the oral health in children and adolescents; an evaluation of their quality and utility in the light of modern perspectives of caries management.

    PubMed

    Skeie, Marit S; Klock, Kristin S

    2014-04-30

    Recording reliable oral health data is a challenge. The aims were a) to outline different Scandinavian systems of oral health monitoring, b) to evaluate the quality and utility of the collected data in the light of modern concepts of disease management and to suggest improvements. The information for in this study was related to (a) children and adolescents, (b) oral health data and (c) routines for monitoring such data. This meant information available in the official web sites of the "KOSTRA-data" (Municipality-State-Report) in Norway, the Swedish National Board of Health and Welfare ("Socialstyrelsen") and Oral Health Register (the SCOR system, National Board of Health) in Denmark. A potential for increasing the reliability and validity of the data existed. Routines for monitoring other oral diseases than caries were limited. Compared with the other Scandinavian countries, the data collection system in Denmark appeared more functional and had adopted more modern concepts of disease management than other systems. In the light of modern concepts of caries management, data collected elsewhere had limited utility. The Scandinavian systems of health reporting had much in common, but some essential differences existed. If the quality of epidemiological data were enhanced, it would be possible to use the data for planning oral health care. Routines and procedures should be improved and updated in accordance with the modern ideas about caries prevention and therapy. For appropriate oral health planning in an organised dental service, reporting of enamel caries is essential.

  4. A real-time monitoring system for night glare protection

    NASA Astrophysics Data System (ADS)

    Ma, Jun; Ni, Xuxiang

    2010-11-01

    When capturing a dark scene with a high bright object, the monitoring camera will be saturated in some regions and the details will be lost in and near these saturated regions because of the glare vision. This work aims at developing a real-time night monitoring system. The system can decrease the influence of the glare vision and gain more details from the ordinary camera when exposing a high-contrast scene like a car with its headlight on during night. The system is made up of spatial light modulator (The liquid crystal on silicon: LCoS), image sensor (CCD), imaging lens and DSP. LCoS, a reflective liquid crystal, can modular the intensity of reflective light at every pixel as a digital device. Through modulation function of LCoS, CCD is exposed with sub-region. With the control of DSP, the light intensity is decreased to minimum in the glare regions, and the light intensity is negative feedback modulated based on PID theory in other regions. So that more details of the object will be imaging on CCD and the glare protection of monitoring system is achieved. In experiments, the feedback is controlled by the embedded system based on TI DM642. Experiments shows: this feedback modulation method not only reduces the glare vision to improve image quality, but also enhances the dynamic range of image. The high-quality and high dynamic range image is real-time captured at 30hz. The modulation depth of LCoS determines how strong the glare can be removed.

  5. Comparison of exposure estimation methods for air pollutants: ambient monitoring data and regional air quality simulation.

    PubMed

    Bravo, Mercedes A; Fuentes, Montserrat; Zhang, Yang; Burr, Michael J; Bell, Michelle L

    2012-07-01

    Air quality modeling could potentially improve exposure estimates for use in epidemiological studies. We investigated this application of air quality modeling by estimating location-specific (point) and spatially-aggregated (county level) exposure concentrations of particulate matter with an aerodynamic diameter less than or equal to 2.5 μm (PM(2.5)) and ozone (O(3)) for the eastern U.S. in 2002 using the Community Multi-scale Air Quality (CMAQ) modeling system and a traditional approach using ambient monitors. The monitoring approach produced estimates for 370 and 454 counties for PM(2.5) and O(3), respectively. Modeled estimates included 1861 counties, covering 50% more population. The population uncovered by monitors differed from those near monitors (e.g., urbanicity, race, education, age, unemployment, income, modeled pollutant levels). CMAQ overestimated O(3) (annual normalized mean bias=4.30%), while modeled PM(2.5) had an annual normalized mean bias of -2.09%, although bias varied seasonally, from 32% in November to -27% in July. Epidemiology may benefit from air quality modeling, with improved spatial and temporal resolution and the ability to study populations far from monitors that may differ from those near monitors. However, model performance varied by measure of performance, season, and location. Thus, the appropriateness of using such modeled exposures in health studies depends on the pollutant and metric of concern, acceptable level of uncertainty, population of interest, study design, and other factors. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Multileaf collimator performance monitoring and improvement using semiautomated quality control testing and statistical process control.

    PubMed

    Létourneau, Daniel; Wang, An; Amin, Md Nurul; Pearce, Jim; McNiven, Andrea; Keller, Harald; Norrlinger, Bernhard; Jaffray, David A

    2014-12-01

    High-quality radiation therapy using highly conformal dose distributions and image-guided techniques requires optimum machine delivery performance. In this work, a monitoring system for multileaf collimator (MLC) performance, integrating semiautomated MLC quality control (QC) tests and statistical process control tools, was developed. The MLC performance monitoring system was used for almost a year on two commercially available MLC models. Control charts were used to establish MLC performance and assess test frequency required to achieve a given level of performance. MLC-related interlocks and servicing events were recorded during the monitoring period and were investigated as indicators of MLC performance variations. The QC test developed as part of the MLC performance monitoring system uses 2D megavoltage images (acquired using an electronic portal imaging device) of 23 fields to determine the location of the leaves with respect to the radiation isocenter. The precision of the MLC performance monitoring QC test and the MLC itself was assessed by detecting the MLC leaf positions on 127 megavoltage images of a static field. After initial calibration, the MLC performance monitoring QC test was performed 3-4 times/week over a period of 10-11 months to monitor positional accuracy of individual leaves for two different MLC models. Analysis of test results was performed using individuals control charts per leaf with control limits computed based on the measurements as well as two sets of specifications of ± 0.5 and ± 1 mm. Out-of-specification and out-of-control leaves were automatically flagged by the monitoring system and reviewed monthly by physicists. MLC-related interlocks reported by the linear accelerator and servicing events were recorded to help identify potential causes of nonrandom MLC leaf positioning variations. The precision of the MLC performance monitoring QC test and the MLC itself was within ± 0.22 mm for most MLC leaves and the majority of the

  7. Multileaf collimator performance monitoring and improvement using semiautomated quality control testing and statistical process control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Létourneau, Daniel, E-mail: daniel.letourneau@rmp.uh.on.ca; McNiven, Andrea; Keller, Harald

    2014-12-15

    Purpose: High-quality radiation therapy using highly conformal dose distributions and image-guided techniques requires optimum machine delivery performance. In this work, a monitoring system for multileaf collimator (MLC) performance, integrating semiautomated MLC quality control (QC) tests and statistical process control tools, was developed. The MLC performance monitoring system was used for almost a year on two commercially available MLC models. Control charts were used to establish MLC performance and assess test frequency required to achieve a given level of performance. MLC-related interlocks and servicing events were recorded during the monitoring period and were investigated as indicators of MLC performance variations. Methods:more » The QC test developed as part of the MLC performance monitoring system uses 2D megavoltage images (acquired using an electronic portal imaging device) of 23 fields to determine the location of the leaves with respect to the radiation isocenter. The precision of the MLC performance monitoring QC test and the MLC itself was assessed by detecting the MLC leaf positions on 127 megavoltage images of a static field. After initial calibration, the MLC performance monitoring QC test was performed 3–4 times/week over a period of 10–11 months to monitor positional accuracy of individual leaves for two different MLC models. Analysis of test results was performed using individuals control charts per leaf with control limits computed based on the measurements as well as two sets of specifications of ±0.5 and ±1 mm. Out-of-specification and out-of-control leaves were automatically flagged by the monitoring system and reviewed monthly by physicists. MLC-related interlocks reported by the linear accelerator and servicing events were recorded to help identify potential causes of nonrandom MLC leaf positioning variations. Results: The precision of the MLC performance monitoring QC test and the MLC itself was within ±0.22 mm for most MLC

  8. Real-time water quality monitoring and providing water quality information to the Baltimore Community

    EPA Science Inventory

    EPA and the U.S. Geological Survey (USGS) have initiated the “Village Blue” research project to provide real-time water quality monitoring data to the Baltimore community and increase public awareness about local water quality in Baltimore Harbor and the Chesapeake Ba...

  9. Resilient Monitoring Systems: Architecture, Design, and Application to Boiler/Turbine Plant

    DOE PAGES

    Garcia, Humberto E.; Lin, Wen-Chiao; Meerkov, Semyon M.; ...

    2014-11-01

    Resilient monitoring systems, considered in this paper, are sensor networks that degrade gracefully under malicious attacks on their sensors, causing them to project misleading information. The goal of this work is to design, analyze, and evaluate the performance of a resilient monitoring system intended to monitor plant conditions (normal or anomalous). The architecture developed consists of four layers: data quality assessment, process variable assessment, plant condition assessment, and sensor network adaptation. Each of these layers is analyzed by either analytical or numerical tools. The performance of the overall system is evaluated using a simplified boiler/turbine plant. The measure of resiliencymore » is quantified using Kullback-Leibler divergence, and is shown to be sufficiently high in all scenarios considered.« less

  10. Technology Transfer Opportunities: Automated Ground-Water Monitoring

    USGS Publications Warehouse

    Smith, Kirk P.; Granato, Gregory E.

    1997-01-01

    Introduction A new automated ground-water monitoring system developed by the U.S. Geological Survey (USGS) measures and records values of selected water-quality properties and constituents using protocols approved for manual sampling. Prototypes using the automated process have demonstrated the ability to increase the quantity and quality of data collected and have shown the potential for reducing labor and material costs for ground-water quality data collection. Automation of water-quality monitoring systems in the field, in laboratories, and in industry have increased data density and utility while reducing operating costs. Uses for an automated ground-water monitoring system include, (but are not limited to) monitoring ground-water quality for research, monitoring known or potential contaminant sites, such as near landfills, underground storage tanks, or other facilities where potential contaminants are stored, and as an early warning system monitoring groundwater quality near public water-supply wells.

  11. [Real-time feedback systems for improvement of resuscitation quality].

    PubMed

    Lukas, R P; Van Aken, H; Engel, P; Bohn, A

    2011-07-01

    The quality of chest compression is a determinant of survival after cardiac arrest. Therefore, the European Resuscitation Council (ERC) 2010 guidelines on resuscitation strongly focus on compression quality. Despite its impact on survival, observational studies have shown that chest compression quality is not reached by professional rescue teams. Real-time feedback devices for resuscitation are able to measure chest compression during an ongoing resuscitation attempt through a sternal sensor equipped with a motion and pressure detection system. In addition to the electrocardiograph (ECG) ventilation can be detected by transthoracic impedance monitoring. In cases of quality deviation, such as shallow chest compression depth or hyperventilation, feedback systems produce visual or acoustic alarms. Rescuers can thereby be supported and guided to the requested quality in chest compression and ventilation. Feedback technology is currently available both as a so-called stand-alone device and as an integrated feature in a monitor/defibrillator unit. Multiple studies have demonstrated sustainable enhancement in the education of resuscitation due to the use of real-time feedback technology. There is evidence that real-time feedback for resuscitation combined with training and debriefing strategies can improve both resuscitation quality and patient survival. Chest compression quality is an independent predictor for survival in resuscitation and should therefore be measured and documented in further clinical multicenter trials.

  12. Staff acceptance of video monitoring for coordination: a video system to support perioperative situation awareness.

    PubMed

    Kim, Young Ju; Xiao, Yan; Hu, Peter; Dutton, Richard

    2009-08-01

    To understand staff acceptance of a remote video monitoring system for operating room (OR) coordination. Improved real-time remote visual access to OR may enhance situational awareness but also raises privacy concerns for patients and staff. Survey. A system was implemented in a six-room surgical suite to display OR monitoring video at an access restricted control desk area. Image quality was manipulated to improve staff acceptance. Two months after installation, interviews and a survey were conducted on staff acceptance of video monitoring. About half of all OR personnel responded (n = 63). Overall levels of concerns were low, with 53% rated no concerns and 42% little concern. Top two reported uses of the video were to see if cases are finished and to see if a room is ready. Viewing the video monitoring system as useful did not reduce levels of concern. Staff in supervisory positions perceived less concern about the system's impact on privacy than did those supervised (p < 0.03). Concerns for patient privacy correlated with concerns for staff privacy and performance monitoring. Technical means such as manipulating image quality helped staff acceptance. Manipulation of image quality resulted overall acceptance of monitoring video, with residual levels of concerns. OR nurses may express staff privacy concern in the form of concerns over patient privacy. This study provided suggestions for technological and implementation strategies of video monitoring for coordination use in OR. Deployment of communication technology and integration of clinical information will likely raise concerns over staff privacy and performance monitoring. The potential gain of increased information access may be offset by negative impact of a sense of loss of autonomy.

  13. 40 CFR Appendix A to Part 58 - Quality Assurance Requirements for SLAMS, SPMs and PSD Air Monitoring

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... monitor. 3.3.4.4Pb Performance Evaluation Program (PEP) Procedures. Each year, one performance evaluation... Information 2. Quality System Requirements 3. Measurement Quality Check Requirements 4. Calculations for Data... 10 of this appendix) and at a national level in references 1, 2, and 3 of this appendix. 1...

  14. 40 CFR Appendix A to Part 58 - Quality Assurance Requirements for SLAMS, SPMs and PSD Air Monitoring

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... monitor. 3.3.4.4Pb Performance Evaluation Program (PEP) Procedures. Each year, one performance evaluation... Information 2. Quality System Requirements 3. Measurement Quality Check Requirements 4. Calculations for Data... 10 of this appendix) and at a national level in references 1, 2, and 3 of this appendix. 1...

  15. Air pollution due to traffic, air quality monitoring along three sections of National Highway N-5, Pakistan.

    PubMed

    Ali, Mahboob; Athar, Makshoof

    2008-01-01

    Transportation system has contributed significantly to the development of human civilization; on the other hand it has an enormous impact on the ambient air quality in several ways. In this paper the air and noise pollution at selected sites along three sections of National Highway was monitored. Pakistan National Highway Authority has started a Highway Improvement program for rehabilitations and maintenance of National highways to improve the traffic flows, and would ultimately improve the air quality along highways. The ambient air quality and noise level was monitored at nine different locations along these sections of highways to quantify the air pollution. The duration of monitoring at individual location was 72 h. The most of the sampling points were near the urban or village population, schools or hospitals, in order to quantify the air pollution at most affected locations along these roads. A database consisting of information regarding the source of emission, local metrology and air quality may be created to assess the profile of air quality in the area.

  16. Monitoring water quality by remote sensing

    NASA Technical Reports Server (NTRS)

    Brown, R. L. (Principal Investigator)

    1977-01-01

    The author has identified the following significant results. A limited study was conducted to determine the applicability of remote sensing for evaluating water quality conditions in the San Francisco Bay and delta. Considerable supporting data were available for the study area from other than overflight sources, but short-term temporal and spatial variability precluded their use. The study results were not sufficient to shed much light on the subject, but it did appear that, with the present state of the art in image analysis and the large amount of ground truth needed, remote sensing has only limited application in monitoring water quality.

  17. Cost-effective water quality assessment through the integration of monitoring data and modeling results

    NASA Astrophysics Data System (ADS)

    Lobuglio, Joseph N.; Characklis, Gregory W.; Serre, Marc L.

    2007-03-01

    Sparse monitoring data and error inherent in water quality models make the identification of waters not meeting regulatory standards uncertain. Additional monitoring can be implemented to reduce this uncertainty, but it is often expensive. These costs are currently a major concern, since developing total maximum daily loads, as mandated by the Clean Water Act, will require assessing tens of thousands of water bodies across the United States. This work uses the Bayesian maximum entropy (BME) method of modern geostatistics to integrate water quality monitoring data together with model predictions to provide improved estimates of water quality in a cost-effective manner. This information includes estimates of uncertainty and can be used to aid probabilistic-based decisions concerning the status of a water (i.e., impaired or not impaired) and the level of monitoring needed to characterize the water for regulatory purposes. This approach is applied to the Catawba River reservoir system in western North Carolina as a means of estimating seasonal chlorophyll a concentration. Mean concentration and confidence intervals for chlorophyll a are estimated for 66 reservoir segments over an 11-year period (726 values) based on 219 measured seasonal averages and 54 model predictions. Although the model predictions had a high degree of uncertainty, integration of modeling results via BME methods reduced the uncertainty associated with chlorophyll estimates compared with estimates made solely with information from monitoring efforts. Probabilistic predictions of future chlorophyll levels on one reservoir are used to illustrate the cost savings that can be achieved by less extensive and rigorous monitoring methods within the BME framework. While BME methods have been applied in several environmental contexts, employing these methods as a means of integrating monitoring and modeling results, as well as application of this approach to the assessment of surface water monitoring networks

  18. OPTICAL REMOTE SENSING FOR AIR QUALITY MONITORING

    EPA Science Inventory

    The paper outlines recent developments in using optical remote sensing (ORS) instruments for air quality monitoring both for gaseous pollutants and airborne particulate matter (PM). The U.S. Environmental Protection Agency (EPA) has been using open-path Fourier transform infrared...

  19. External Quality Monitoring of the Cervical Cytopathological Exams in the Rio de Janeiro City.

    PubMed

    Rocha, Vânia Stiepanowez de Oliveira; Malfacini, Solange da Silva; Gomes, Alex Moreira; Rocha, Cláudia Ramos Marques da

    2018-06-20

     To discuss the implementation and contributions of the External Quality Monitoring in the city of Rio de Janeiro and to analyze the performance of the main providers of cervical cytopathology in this city from September 2013 to March 2017, here referred to as "Alpha laboratory" and "Beta laboratory."  Observational, cross-sectional, retrospective study using information from the Cervical Cancer Control Information System (SISCOLO, in the Portuguese acronym), municipal coordination module, External Quality Monitoring report. The proportions of false positives, false negatives, unsatisfactory samples and rejected samples were estimated. The agreement among the observers was analyzed through the Kappa index and the reduction of disagreements in the period for each laboratory studied, comparing the results of each cycle.  A total of 19,158 examinations were selected, of which 19,130 (99.85%) were monitored, 16.649 (87, 03%) were reviewed by the External Quality Monitoring Unit, 2,481 (12,97%) were rejected and 441 (2,65%) were considered unsatisfactory. The "Beta laboratory" presented excellent concordance in all cycles; the "Alpha laboratory" had good concordance in the first two cycles (K = 0.76 and 0.79), becoming excellent in the following four cycles. The average Kappa index was 0.85, with median of 0.86. The percentage of diagnostic disagreement was 6.63% of the reviewed exams, of which 5.38% required a change of conduct CONCLUSION:  External Quality Monitoring is an exercise in diagnostic improvement, and its implementation was fundamental to ensure the reliability of the cytopathological exams in the city of Rio de Janeiro. Thieme Revinter Publicações Ltda Rio de Janeiro, Brazil.

  20. An Air Quality Data Analysis System for Interrelating Effects, Standards and Needed Source Reductions

    ERIC Educational Resources Information Center

    Larsen, Ralph I.

    1973-01-01

    Makes recommendations for a single air quality data system (using average time) for interrelating air pollution effects, air quality standards, air quality monitoring, diffusion calculations, source-reduction calculations, and emission standards. (JR)

  1. Guidelines and standard procedures for continuous water-quality monitors: Site selection, field operation, calibration, record computation, and reporting

    USGS Publications Warehouse

    Wagner, Richard J.; Mattraw, Harold C.; Ritz, George F.; Smith, Brett A.

    2000-01-01

    The U.S. Geological Survey uses continuous water-quality monitors to assess variations in the quality of the Nation's surface water. A common system configuration for data collection is the four-parameter water-quality monitoring system, which collects temperature, specific conductance, dissolved oxygen, and pH data, although systems can be configured to measure other properties such as turbidity or chlorophyll. The sensors that are used to measure these water properties require careful field observation, cleaning, and calibration procedures, as well as thorough procedures for the computation and publication of final records. Data from sensors can be used in conjunction with collected samples and chemical analyses to estimate chemical loads. This report provides guidelines for site-selection considerations, sensor test methods, field procedures, error correction, data computation, and review and publication processes. These procedures have evolved over the past three decades, and the process continues to evolve with newer technologies.

  2. A longitudinal, randomized, and prospective study of nocturnal monitoring in children and adolescents with epilepsy: Effects on quality of life and sleep.

    PubMed

    Borusiak, Peter; Bast, Thomas; Kluger, Gerhard; Weidenfeld, Andrea; Langer, Thorsten; Jenke, Andreas C W; Wiegand, Gert

    2016-08-01

    Most studies on seizure detection systems focus more on the effectiveness of devices than on their practicability in and impact on everyday life. Our study investigated the impact of a technical monitoring system on subjective quality of sleep and the lives of affected families. Furthermore, we evaluated the impact of anxiety levels on seizure monitoring and vice versa. Forty-three patients with newly diagnosed epilepsy were included. Initially, the families decided whether they did (group 1, n=27) or did not (group 2, n=16) want to use a monitoring device. In group 1, patients were randomly assigned to using Epi-Care® (group 1A, n=14) or an audio baby monitor (group 1B, n=13). Quality of life was assessed at two points (t1, at the start of the study and t2, at 5-7months of follow-up) using the SF-12, Kindl-R, and "Familien-Belastungs-Fragebogen" (German version of the "Impact on Family Scale"). In addition, parental anxiety was measured using the State-Trait Anxiety-Inventory, and subjective quality of sleep was measured using the Pittsburgh Sleep Quality Index. Statistical analysis focused on the possible differences between groups 1 and 2 that may influence parents' decisions and the effects of the presence and types of technical monitoring over time. Anxiety levels were not significantly different between the groups with and without monitoring (group 1 vs. group 2). We also found no statistically significant, substantial baseline differences between the Epi-Care® and audio baby monitor groups, with at least medium effect sizes (group 1A vs. group 1B). Parents' health-related mental quality of life measured via the SF-12 increased significantly over time in all groups. By tendency, the fear of further seizures as well as the frequency of cosleeping arrangements in the monitoring group decreased during the study and approached the stable values of the control group. Individual parental anxiety levels are not crucial in the decision regarding the use of a

  3. Remote maintenance monitoring system

    NASA Technical Reports Server (NTRS)

    Simpkins, Lorenz G. (Inventor); Owens, Richard C. (Inventor); Rochette, Donn A. (Inventor)

    1992-01-01

    A remote maintenance monitoring system retrofits to a given hardware device with a sensor implant which gathers and captures failure data from the hardware device, without interfering with its operation. Failure data is continuously obtained from predetermined critical points within the hardware device, and is analyzed with a diagnostic expert system, which isolates failure origin to a particular component within the hardware device. For example, monitoring of a computer-based device may include monitoring of parity error data therefrom, as well as monitoring power supply fluctuations therein, so that parity error and power supply anomaly data may be used to trace the failure origin to a particular plane or power supply within the computer-based device. A plurality of sensor implants may be rerofit to corresponding plural devices comprising a distributed large-scale system. Transparent interface of the sensors to the devices precludes operative interference with the distributed network. Retrofit capability of the sensors permits monitoring of even older devices having no built-in testing technology. Continuous real time monitoring of a distributed network of such devices, coupled with diagnostic expert system analysis thereof, permits capture and analysis of even intermittent failures, thereby facilitating maintenance of the monitored large-scale system.

  4. Assessing and monitoring soil quality at agricultural waste disposal areas-Soil Indicators

    NASA Astrophysics Data System (ADS)

    Doula, Maria; Kavvadias, Victor; Sarris, Apostolos; Lolos, Polykarpos; Liakopoulou, Nektaria; Hliaoutakis, Aggelos; Kydonakis, Aris

    2014-05-01

    The necessity of elaborating indicators is one of the priorities identified by the United Nations Convention to Combat Desertification (UNCCD). The establishment of an indicator monitoring system for environmental purposes is dependent on the geographical scale. Some indicators such as rain seasonality or drainage density are useful over large areas, but others such as soil depth, vegetation cover type, and land ownership are only applicable locally. In order to practically enhance the sustainability of land management, research on using indicators for assessing land degradation risk must initially focus at local level because management decisions by individual land users are taken at this level. Soils that accept wastes disposal, apart from progressive degradation, may cause serious problems to the surrounding environment (humans, animals, plants, water systems, etc.), and thus, soil quality should be necessarily monitored. Therefore, quality indicators, representative of the specific waste type, should be established and monitored periodically. Since waste composition is dependent on their origin, specific indicators for each waste type should be established. Considering agricultural wastes, such a specification, however, could be difficult, since almost all agricultural wastes are characterized by increased concentrations of the same elements, namely, phosphorous, nitrogen, potassium, sulfur, etc.; contain large amounts of organic matter; and have very high values of chemical oxygen demand (COD), biochemical oxygen demand (BOD), and electrical conductivity. Two LIFE projects, namely AgroStrat and PROSODOL are focused on the identification of soil indicators for the assessment of soil quality at areas where pistachio wastes and olive mill wastes are disposed, respectively. Many soil samples were collected periodically for 2 years during PROSODOL and one year during AgroStrat (this project is in progress) from waste disposal areas and analyzed for 23 parameters

  5. Environmental assessment of three egg production systems--Part I: Monitoring system and indoor air quality.

    PubMed

    Zhao, Y; Shepherd, T A; Li, H; Xin, H

    2015-03-01

    To comprehensively assess conventional vs. some alternative laying-hen housing systems under U.S. production conditions, a multi-institute and multi-disciplinary project, known as the Coalition for Sustainable Egg Supply (CSES) study, was carried out at a commercial egg production farm in the Midwestern United States over two single-cycle production flocks. The housing systems studied include a conventional cage house (200,000 hen capacity), an aviary house (50,000 hen capacity), and an enriched colony house (50,000 hen capacity). As an integral part of the CSES project, continual environmental monitoring over a 27-month period described in this paper quantifies indoor gaseous and particulate matter concentrations, thermal environment, and building ventilation rate of each house. Results showed that similar indoor thermal environments in all three houses were maintained through ventilation management and environmental control. Gaseous and particulate matter concentrations of the enriched colony house were comparable with those of the conventional cage house. In comparison, the aviary house had poorer indoor air quality, especially in wintertime, resulting from the presence of floor litter (higher ammonia levels) and hens' activities (higher particulate matter levels) in it. Specifically, daily mean indoor ammonia concentrations had the 95% confidence interval values of 3.8 to 4.2 (overall mean of 4.0) ppm for the conventional cage house; 6.2 to 7.2 (overall mean of 6.7) ppm for the aviary house; and 2.7 to 3.0 (overall mean of 2.8) ppm for the enriched colony house. The 95% confidence interval (overall mean) values of daily mean indoor carbon dioxide concentrations were 1997 to 2170 (2083) ppm for the conventional cage house, 2367 to 2582 (2475) ppm for the aviary house, and 2124 to 2309 (2216) ppm for the enriched colony house. Daily mean indoor methane concentrations were similar for all three houses, with 95% confidence interval values of 11.1 to 11.9 (overall

  6. Inductive monitoring system constructed from nominal system data and its use in real-time system monitoring

    NASA Technical Reports Server (NTRS)

    Iverson, David L. (Inventor)

    2008-01-01

    The present invention relates to an Inductive Monitoring System (IMS), its software implementations, hardware embodiments and applications. Training data is received, typically nominal system data acquired from sensors in normally operating systems or from detailed system simulations. The training data is formed into vectors that are used to generate a knowledge database having clusters of nominal operating regions therein. IMS monitors a system's performance or health by comparing cluster parameters in the knowledge database with incoming sensor data from a monitored-system formed into vectors. Nominal performance is concluded when a monitored-system vector is determined to lie within a nominal operating region cluster or lies sufficiently close to a such a cluster as determined by a threshold value and a distance metric. Some embodiments of IMS include cluster indexing and retrieval methods that increase the execution speed of IMS.

  7. Information for mental health systems: an instrument for policy-making and system service quality.

    PubMed

    Lora, A; Lesage, A; Pathare, S; Levav, I

    2017-08-01

    Information is crucial in mental healthcare, yet it remains undervalued by stakeholders. Its absence undermines rationality in planning, makes it difficult to monitor service quality improvement, impedes accountability and human rights monitoring. For international organizations (e.g., WHO, OECD), information is indispensable for achieving better outcomes in mental health policies, services and programs. This article reviews the importance of developing system level information with reference to inputs, processes and outputs, analyzes available tools for collecting and summarizing information, highlights the various goals of information gathering, discusses implementation issues and charts the way forward. Relevant publications and research were consulted, including WHO studies that purport to promote the use of information systems to upgrade mental health care in high- and low-middle income countries. Studies have shown that once information has been collected by relevant systems and analyzed through indicator schemes, it can be put to many uses. Monitoring mental health services, represents a first step in using information. In addition, studies have noted that information is a prime resource in many other areas such as evaluation of quality of care against evidence based standards of care. Services data may support health services research where it is possible to link mental health data with other health and non-health databases. Information systems are required to carefully monitor involuntary admissions, restrain and seclusion, to reduce human rights violations in care facilities. Information has been also found useful for policy makers, to monitor the implementation of policies, to evaluate their impact, to rationally allocate funding and to create new financing models. Despite its manifold applications, Information systems currently face many problems such as incomplete recording, poor data quality, lack of timely reporting and feedback, and limited

  8. Urine Monitoring System

    NASA Technical Reports Server (NTRS)

    Feedback, Daniel L.; Cibuzar, Branelle R.

    2009-01-01

    The Urine Monitoring System (UMS) is a system designed to collect an individual crewmember's void, gently separate urine from air, accurately measure void volume, allow for void sample acquisition, and discharge remaining urine into the Waste Collector Subsystem (WCS) onboard the International Space Station. The Urine Monitoring System (UMS) is a successor design to the existing Space Shuttle system and will resolve anomalies such as: liquid carry-over, inaccurate void volume measurements, and cross contamination in void samples. The crew will perform an evaluation of airflow at the ISS UMS urinal hose interface, a calibration evaluation, and a full user interface evaluation. o The UMS can be used to facilitate non-invasive methods for monitoring crew health, evaluation of countermeasures, and implementation of a variety of biomedical research protocols on future exploration missions.

  9. Monitoring technologies for the evaluation of a Soil-Aquifer-Treatment system in coastal aquifer environments.

    NASA Astrophysics Data System (ADS)

    Kallioras, Andreas; Tsertou, Athanasia; Foglia, Laura; Bumberger, Jan; Vienken, Thomas; Dietrich, Peter; Schüth, Christoph

    2014-05-01

    Artificial recharge of groundwater has an important role to play in water reuse. Treated sewage effluent can be infiltrated into the ground for recharge of aquifers. As the effluent water moves through the soil and the aquifer, it undergoes significant quality improvements through physical, chemical, and biological processes in the underground environment. Collectively, these processes and the water quality improvement obtained are called soil-aquifer-treatment (SAT) or geopurification. Recharge systems for SAT can be designed as infiltration-recovery systems, where all effluent water is recovered as such from the aquifer, or after blending with native groundwater. SAT typically removes essentially all suspended solids, biochemical oxygen demand (BOD), and pathogens (viruses, bacteria, protozoa, and helminthic eggs). Concentrations of synthetic organic carbon, phosphorous, and heavy metals are greatly reduced. The pilot site of LTCP will involve the employment of infiltration basins, which will be using waters of impaired quality as a recharge source, and hence acting as a Soil-Aquifer-Treatment, SAT, system. T he LTCP site will be employed as a pilot SAT system complemented by new technological developments, which will be providing continuous monitoring of the quantitative and qualitative characteristics of infiltrating groundwater through all hydrologic zones (i.e. surface, unsaturated and saturated zone). This will be achieved through the development and installation of an integrated system of prototype sensors, installed on-site, and offering a continuous evaluation of the performance of the SAT system. An integrated approach of the performance evaluation of any operating SAT system should aim at parallel monitoring of all hydrologic zones, proving the sustainability of all involved water quality treatment processes within unsaturated and saturated zone. Hence a prototype system of Time Domain Reflectometry (TDR) sensors will be developed, in order to achieve

  10. Walnut creek watershed monitoring project, Iowa: Monitoring water quality in response to prairie restoration

    USGS Publications Warehouse

    Schilling, K.E.; Thompson, C.A.

    2000-01-01

    Land use and surface water data for nitrogen and pesticides (1995 to 1997) are reported for the Walnut Creek Watershed Monitoring Project, Jasper County Iowa. The Walnut Creek project was established in 1995 as a nonpoint source monitoring program in relation to watershed habitat restoration and agricultural management changes implemented at the Neal Smith National Wildlife Refuge by the U.S. Fish and Wildlife Service. The monitoring project utilizes a paired-watershed approach (Walnut and Squaw creeks) as well as upstream/downstream comparisons on Walnut for analysis and tracking of trends. From 1992 to 1997, 13.4 percent of the watershed was converted from row crop to native prairie in the Walnut Creek watershed. Including another 6 percent of watershed farmed on a cash-rent basis, land use changes have been implemented on 19.4 percent of the watershed by the USFWS. Nitrogen and pesticide applications were reduced an estimated 18 percent and 28 percent in the watershed from land use changes. Atrazine was detected most often in surface water with frequencies of detection ranging from 76-86 percent. No significant differences were noted in atrazine concentrations between Walnut and Squaw Creek. Nitrate-N concentrations measured in both watersheds were similar; both basins showed a similar pattern of detection and an overall reduction in nitrate-N concentrations from upstream to downstream monitoring sites. Water quality improvements are suggested by nitrate-N and chloride ratios less than one in the Walnut Creek watershed and low nitrate-N concentrations measured in the subbasin of Walnut Creek containing the greatest amount of land use changes. Atrazine and nitrate-N concentrations from the lower portion of the Walnut Creek watershed (including the prairie restoration area) may be decreasing in relation to the upstream untreated component of the watershed. The frequencies of pesticide detections and mean nitrate-N concentrations appear related to the percentage of

  11. How Much Will It Cost To Monitor Microbial Drinking Water Quality in Sub-Saharan Africa?

    PubMed

    Delaire, Caroline; Peletz, Rachel; Kumpel, Emily; Kisiangani, Joyce; Bain, Robert; Khush, Ranjiv

    2017-06-06

    Microbial water quality monitoring is crucial for managing water resources and protecting public health. However, institutional testing activities in sub-Saharan Africa are currently limited. Because the economics of water quality testing are poorly understood, the extent to which cost may be a barrier to monitoring in different settings is unclear. This study used cost data from 18 African monitoring institutions (piped water suppliers and health surveillance agencies in six countries) and estimates of water supply type coverage from 15 countries to assess the annual financial requirements for microbial water testing at both national and regional levels, using World Health Organization recommendations for sampling frequency. We found that a microbial water quality test costs 21.0 ± 11.3 USD, on average, including consumables, equipment, labor, and logistics, which is higher than previously calculated. Our annual cost estimates for microbial monitoring of piped supplies and improved point sources ranged between 8 000 USD for Equatorial Guinea and 1.9 million USD for Ethiopia, depending primarily on the population served but also on the distribution of piped water system sizes. A comparison with current national water and sanitation budgets showed that the cost of implementing prescribed testing levels represents a relatively modest proportion of existing budgets (<2%). At the regional level, we estimated that monitoring the microbial quality of all improved water sources in sub-Saharan Africa would cost 16.0 million USD per year, which is minimal in comparison to the projected annual capital costs of achieving Sustainable Development Goal 6.1 of safe water for all (14.8 billion USD).

  12. Recent developments in water quality monitoring for Space Station reclaimed wastewaters

    NASA Technical Reports Server (NTRS)

    Small, John W.; Verostko, Charles E.; Linton, Arthur T.; Burchett, Ray

    1987-01-01

    This paper discusses the recent developments in water quality monitoring for Space Station reclaimed wastewaters. A preprototype unit that contains an ultraviolet absorbance organic carbon monitor integrated with pH and conductivity sensors is presented. The preprototype has provisions for automated operation and is a reagentless flow-through system without any gas/liquid interfaces. The organic carbon monitor detects by utraviolet absorbance the organic impurities in reclaimed wastewater which may be correlated to the organic carbon content of the water. A comparison of the preprototype organic carbon detection values with actual total organic carbon measurements is presented. The electrolyte double junction concept for the pH sensor and fixed electrodes for both the pH and conductivity sensors are discussed. In addition, the development of a reagentless organic carbon analyzer that incorporates ultraviolet oxidation and infrared detection is presented. Detection sensitivities, hardware development, and operation are included.

  13. Application of Aquaculture Monitoring System Based on CC2530

    NASA Astrophysics Data System (ADS)

    Chen, H. L.; Liu, X. Q.

    In order to improve the intelligent level of aquaculture technology, this paper puts forward a remote wireless monitoring system based on ZigBee technology, GPRS technology and Android mobile phone platform. The system is composed of wireless sensor network (WSN), GPRS module, PC server, and Android client. The WSN was set up by CC2530 chips based on ZigBee protocol, to realize the collection of water quality parameters such as the water level, temperature, PH and dissolved oxygen. The GPRS module realizes remote communication between WSN and PC server. Android client communicates with server to monitor the level of water quality. The PID (proportion, integration, differentiation) control is adopted in the control part, the control commands from the android mobile phone is sent to the server, the server again send it to the lower machine to control the water level regulating valve and increasing oxygen pump. After practical testing to the system in Liyang, Jiangsu province, China, temperature measurement accuracy reaches 0.5°C, PH measurement accuracy reaches 0.3, water level control precision can be controlled within ± 3cm, dissolved oxygen control precision can be controlled within ±0.3 mg/L, all the indexes can meet the requirements, this system is very suitable for aquaculture.

  14. Demonstration of subsidence monitoring system

    NASA Astrophysics Data System (ADS)

    Conroy, P. J.; Gyarmaty, J. H.; Pearson, M. L.

    1981-06-01

    Data on coal mine subsidence were studied as a basis for the development of subsidence control technology. Installation, monitoring, and evaluation of three subsidence monitoring instrument systems were examined: structure performance, performance of supported systems, and performance of caving systems. Objectives of the instrument program were: (1) to select, test, assemble, install, monitor, and maintain all instrumentation required for implementing the three subsidence monitoring systems; and (2) to evaluate performance of each instrument individually and as part of the appropriate monitoring system or systems. The use of an automatic level and a rod extensometer for measuring structure performance, and the automatic level, steel tape extensometer, FPBX, FPBI, USBM borehole deformation gauge, and vibrating wire stressmeters for measuring the performance of caving systems are recommended.

  15. Changes in water quality along the course of a river - Classic monitoring versus patrol monitoring

    NASA Astrophysics Data System (ADS)

    Absalon, Damian; Kryszczuk, Paweł; Rutkiewicz, Paweł

    2017-11-01

    Monitoring of water quality is a tool necessary to assess the condition of waterbodies in order to properly formulate water management plans. The paper presents the results of patrol monitoring of a 40-kilometre stretch of the Oder between Racibórz and Koźle. It has been established that patrol monitoring is a good tool for verifying the distribution of points of classic stationary monitoring, particularly in areas subject to varied human impact, where tributaries of the main river are very diversified as regards hydrochemistry. For this reason the results of operational monitoring carried out once every few years may not be reliable and the presented condition of the monitored waterbodies may be far from reality.

  16. Assessing I-Grid(TM) web-based monitoring for power quality and reliability benchmarking

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Divan, Deepak; Brumsickle, William; Eto, Joseph

    2003-04-30

    This paper presents preliminary findings from DOEs pilot program. The results show how a web-based monitoring system can form the basis for aggregation of data and correlation and benchmarking across broad geographical lines. A longer report describes additional findings from the pilot, including impacts of power quality and reliability on customers operations [Divan, Brumsickle, Eto 2003].

  17. A UAV-Mounted Whole Cell Biosensor System for Environmental Monitoring Applications

    PubMed Central

    Lu, Yi; Macias, Dominique; Dean, Zachary S.; Kreger, Nicole R.; Wong, Pak Kin

    2016-01-01

    This study reports the development of a portable whole cell biosensor system for environmental monitoring applications, such as air quality control, water pollution monitoring and radiation leakage detection. The system consists of a lightweight mechanical housing, a temperature regulating system, and a microfluidic bacterial inoculation channel. The overall system, which is less than 200 g, serves as a portable incubator for cell inoculation and can be mounted on an unmanned aerial vehicle for monitoring remote and unreachable locations. The feedback control system maintains the inoculation temperature within 0.05 degree Celsius. The large surface-to-volume ratio of the polydimethylsiloxane microchannel facilitates effective gas exchange for rapid bacterial growth. Molecular dynamic simulation shows effective diffusion of major gas pollutants in PDMS toward gas sensing applications. By optimizing the design, we demonstrate the operation of the system in ambient temperatures from 5°C to 32°C and rapid bacterial growth in microchannels compared to standard bacterial culture techniques. PMID:26584498

  18. Scandinavian systems monitoring the oral health in children and adolescents; an evaluation of their quality and utility in the light of modern perspectives of caries management

    PubMed Central

    2014-01-01

    Background Recording reliable oral health data is a challenge. The aims were a) to outline different Scandinavian systems of oral health monitoring, b) to evaluate the quality and utility of the collected data in the light of modern concepts of disease management and to suggest improvements. Material and methods The information for in this study was related to (a) children and adolescents, (b) oral health data and (c) routines for monitoring such data. This meant information available in the official web sites of the “KOSTRA-data” (Municipality-State-Report) in Norway, the Swedish National Board of Health and Welfare (“Socialstyrelsen”) and Oral Health Register (the SCOR system, National Board of Health) in Denmark. Results A potential for increasing the reliability and validity of the data existed. Routines for monitoring other oral diseases than caries were limited. Compared with the other Scandinavian countries, the data collection system in Denmark appeared more functional and had adopted more modern concepts of disease management than other systems. In the light of modern concepts of caries management, data collected elsewhere had limited utility. Conclusions The Scandinavian systems of health reporting had much in common, but some essential differences existed. If the quality of epidemiological data were enhanced, it would be possible to use the data for planning oral health care. Routines and procedures should be improved and updated in accordance with the modern ideas about caries prevention and therapy. For appropriate oral health planning in an organised dental service, reporting of enamel caries is essential. PMID:24885243

  19. Monitoring and Assuring the Quality of Digital Aerial Data

    NASA Technical Reports Server (NTRS)

    Christopherson, Jon

    2007-01-01

    This viewgraph presentation explains the USGS plan for monitoring and assuring the quality of digital aerial data. The contents include: 1) History of USGS Aerial Imaging Involvement; 2) USGS Research and Results; 3) Outline of USGS Quality Assurance Plan; 4) Other areas of Interest; and 5) Summary

  20. Design and Deployment of Low-Cost Sensors for Monitoring the Water Quality and Fish Behavior in Aquaculture Tanks during the Feeding Process

    PubMed Central

    Parra, Lorena; García, Laura

    2018-01-01

    The monitoring of farming processes can optimize the use of resources and improve its sustainability and profitability. In fish farms, the water quality, tank environment, and fish behavior must be monitored. Wireless sensor networks (WSNs) are a promising option to perform this monitoring. Nevertheless, its high cost is slowing the expansion of its use. In this paper, we propose a set of sensors for monitoring the water quality and fish behavior in aquaculture tanks during the feeding process. The WSN is based on physical sensors, composed of simple electronic components. The system proposed can monitor water quality parameters, tank status, the feed falling and fish swimming depth and velocity. In addition, the system includes a smart algorithm to reduce the energy waste when sending the information from the node to the database. The system is composed of three nodes in each tank that send the information though the local area network to a database on the Internet and a smart algorithm that detects abnormal values and sends alarms when they happen. All the sensors are designed, calibrated, and deployed to ensure its suitability. The greatest efforts have been accomplished with the fish presence sensor. The total cost of the sensors and nodes for the proposed system is less than 90 €. PMID:29494560

  1. Design and Deployment of Low-Cost Sensors for Monitoring the Water Quality and Fish Behavior in Aquaculture Tanks during the Feeding Process.

    PubMed

    Parra, Lorena; Sendra, Sandra; García, Laura; Lloret, Jaime

    2018-03-01

    The monitoring of farming processes can optimize the use of resources and improve its sustainability and profitability. In fish farms, the water quality, tank environment, and fish behavior must be monitored. Wireless sensor networks (WSNs) are a promising option to perform this monitoring. Nevertheless, its high cost is slowing the expansion of its use. In this paper, we propose a set of sensors for monitoring the water quality and fish behavior in aquaculture tanks during the feeding process. The WSN is based on physical sensors, composed of simple electronic components. The system proposed can monitor water quality parameters, tank status, the feed falling and fish swimming depth and velocity. In addition, the system includes a smart algorithm to reduce the energy waste when sending the information from the node to the database. The system is composed of three nodes in each tank that send the information though the local area network to a database on the Internet and a smart algorithm that detects abnormal values and sends alarms when they happen. All the sensors are designed, calibrated, and deployed to ensure its suitability. The greatest efforts have been accomplished with the fish presence sensor. The total cost of the sensors and nodes for the proposed system is less than 90 €.

  2. Developing policy, standard orders, and quality-assurance monitoring for palliative sedation therapy.

    PubMed

    Ghafoor, Virginia L; Silus, Lauren S

    2011-03-15

    The development of a policy, evidence-based standard orders, and monitoring for palliative sedation therapy (PST) is described. Concerns regarding PST at the University of Minnesota Medical Center (UMMC) arose and needed to be addressed in a formal process. A multidisciplinary group consisting of palliative care physicians, nurse practitioners, clinical nurse specialists, and clinical pharmacy specialists reached consensus on the practice model and medications to be used for PST. Major elements of the plan included the development and implementation of an institutional policy for palliative sedation; standard orders for patient care, sedation, and monitoring; education for staff, patients, and patients' family members; and quality-assurance monitoring. A literature review was performed to identify research and guidelines defining the practice of PST. Policy content includes the use of a standard order set linking patient care, medication administration, the monitoring of sedation, and symptom management. Approval of the policy involved several UMMC committees. An evaluation matrix was used to determine critical areas for PST monitoring and to guide development of a form to monitor quality. A retrospective chart audit using the quality-assurance monitoring form assessed baseline sedation medication and patient outcomes. Assessment of compliance began in the fall of 2008, after the policy and standard orders were approved by the UMMC medical executive committee. In 2008, two cases of PST were monitored using the standardized form. PST cases will be continually monitored and analyzed. Development of policy, standard orders, and quality-assurance monitoring for PST required a formal multidisciplinary process. A process-improvement process is critical to defining institutional policy, educational goals, and outcome metrics for PST.

  3. Colorimetric Solid Phase Extraction (CSPE): Using Color to Monitor Spacecraft Water Quality

    NASA Technical Reports Server (NTRS)

    Gazda, Daniel B.; Nolan, Daniel J.; Rutz, Jeffrey A.; Schultz, John R.; Siperko, Lorraine M.; Porter, Marc D.; Lipert, Robert J.; Flint, Stephanie M.; McCoy, J. Torin

    2010-01-01

    In August 2009, an experimental water quality monitoring kit based on Colorimetric Solid Phase Extraction (CSPE) technology was delivered to the International Space Station (ISS). The kit, called the Colorimetric Water Quality Monitoring Kit (CWQMK), was launched as a Station Development Test Objective (SDTO) experiment to evaluate the suitability of CSPE technology for routine use monitoring water quality on the ISS. CSPE is a sorption-spectrophotometric technique that combines colorimetric reagents, solid-phase extraction, and diffuse reflectance spectroscopy to quantify trace analytes in water samples. In CSPE, a known volume of sample is metered through a membrane disk that has been impregnated with an analyte-specific colorimetric reagent and any additives required to optimize the formation of the analyte-reagent complex. As the sample flows through the membrane disk, the target analyte is selectively extracted, concentrated, and complexed. Formation of the analyte-reagent complex causes a detectable change in the color of the membrane disk that is proportional to the amount of analyte present in the sample. The analyte is then quantified by measuring the color of the membrane disk surface using a hand-held diffuse reflectance spectrophotometer (DRS). The CWQMK provides the capability to measure the ionic silver (Ag +) and molecular iodine (I2) in water samples on-orbit. These analytes were selected for the evaluation of CSPE technology because they are the biocides used in the potable water storage and distribution systems on the ISS. Biocides are added to the potable water systems on spacecraft to inhibit microbial growth. On the United States (US) segment of the ISS molecular iodine serves as the biocide, while the Russian space agency utilizes silver as a biocide in their systems. In both cases, the biocides must be maintained at a level sufficient to control bacterial growth, but low enough to avoid any negative effects on crew health. For example, the

  4. Optimizing disinfection by-product monitoring points in a distribution system using cluster analysis.

    PubMed

    Delpla, Ianis; Florea, Mihai; Pelletier, Geneviève; Rodriguez, Manuel J

    2018-06-04

    Trihalomethanes (THMs) and Haloacetic Acids (HAAs) are the main groups detected in drinking water and are consequently strictly regulated. However, the increasing quantity of data for disinfection byproducts (DBPs) produced from research projects and regulatory programs remains largely unexploited, despite a great potential for its use in optimizing drinking water quality monitoring to meet specific objectives. In this work, we developed a procedure to optimize locations and periods for DBPs monitoring based on a set of monitoring scenarios using the cluster analysis technique. The optimization procedure used a robust set of spatio-temporal monitoring results on DBPs (THMs and HAAs) generated from intensive sampling campaigns conducted in a residential sector of a water distribution system. Results shows that cluster analysis allows for the classification of water quality in different groups of THMs and HAAs according to their similarities, and the identification of locations presenting water quality concerns. By using cluster analysis with different monitoring objectives, this work provides a set of monitoring solutions and a comparison between various monitoring scenarios for decision-making purposes. Finally, it was demonstrated that the data from intensive monitoring of free chlorine residual and water temperature as DBP proxy parameters, when processed using cluster analysis, could also help identify the optimal sampling points and periods for regulatory THMs and HAAs monitoring. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Mobile Monitoring and Embedded Control System for Factory Environment

    PubMed Central

    Lian, Kuang-Yow; Hsiao, Sung-Jung; Sung, Wen-Tsai

    2013-01-01

    This paper proposes a real-time method to carry out the monitoring of factory zone temperatures, humidity and air quality using smart phones. At the same time, the system detects possible flames, and analyzes and monitors electrical load. The monitoring also includes detecting the vibrations of operating machinery in the factory area. The research proposes using ZigBee and Wi-Fi protocol intelligent monitoring system integration within the entire plant framework. The sensors on the factory site deliver messages and real-time sensing data to an integrated embedded systems via the ZigBee protocol. The integrated embedded system is built by the open-source 32-bit ARM (Advanced RISC Machine) core Arduino Due module, where the network control codes are built in for the ARM chipset integrated controller. The intelligent integrated controller is able to instantly provide numerical analysis results according to the received data from the ZigBee sensors. The Android APP and web-based platform are used to show measurement results. The built-up system will transfer these results to a specified cloud device using the TCP/IP protocol. Finally, the Fast Fourier Transform (FFT) approach is used to analyze the power loads in the factory zones. Moreover, Near Field Communication (NFC) technology is used to carry out the actual electricity load experiments using smart phones. PMID:24351642

  6. Mobile monitoring and embedded control system for factory environment.

    PubMed

    Lian, Kuang-Yow; Hsiao, Sung-Jung; Sung, Wen-Tsai

    2013-12-17

    This paper proposes a real-time method to carry out the monitoring of factory zone temperatures, humidity and air quality using smart phones. At the same time, the system detects possible flames, and analyzes and monitors electrical load. The monitoring also includes detecting the vibrations of operating machinery in the factory area. The research proposes using ZigBee and Wi-Fi protocol intelligent monitoring system integration within the entire plant framework. The sensors on the factory site deliver messages and real-time sensing data to an integrated embedded systems via the ZigBee protocol. The integrated embedded system is built by the open-source 32-bit ARM (Advanced RISC Machine) core Arduino Due module, where the network control codes are built in for the ARM chipset integrated controller. The intelligent integrated controller is able to instantly provide numerical analysis results according to the received data from the ZigBee sensors. The Android APP and web-based platform are used to show measurement results. The built-up system will transfer these results to a specified cloud device using the TCP/IP protocol. Finally, the Fast Fourier Transform (FFT) approach is used to analyze the power loads in the factory zones. Moreover, Near Field Communication (NFC) technology is used to carry out the actual electricity load experiments using smart phones.

  7. Monitoring changes in Greater Yellowstone Lake water quality following the 1988 wildfires

    NASA Technical Reports Server (NTRS)

    Lathrop, Richard G., Jr.; Vande Castle, John D.; Brass, James A.

    1994-01-01

    The fires that burned the Greater Yellowstone Area (GYA) during the summer of 1988 were the largest ever recorded for the region. Wildfire can have profound indirect effects on associated aquatic ecosystems by increased nutrient loading, sediment, erosion, and runoff. Satellite remote sensing and water quality sampling were used to compare pre- versus post-fire conditions in the GYA's large oliotrophic (high transparency, low productivity) lakes. Inputs of suspended sediment to Jackson Lake appear to have increased. Yellowstone Lake has not shown any discernable shift in water quality. The insights gained separately from the Landsat Thematic and NOAA Advanced Very High Resolution Radiometer (AVHRR) remote sensing systems, along with conventional in-situ sampling, can be combined into a useful water quality monitoring tool.

  8. A water-quality monitoring network for Vallecitos Valley, Alameda County, California

    USGS Publications Warehouse

    Farrar, C.D.

    1980-01-01

    A water-quality monitoring network is proposed to detect the presence of and trace the movement of radioisotopes in the hydrologic system in the vicinity of the Vallecitos Nuclear Center. The source of the radioisotopes is treated industrial wastewater from the Vallecitos Nuclear Center that is discharged into an unnamed tributary of Vallecitos Creek. The effluent infiltrates the alluvium along the stream course, percolates downward to the water table, and mixes with the native ground water in the subsurface. The average daily discharge of effluent to the hydrologic system in 1978 was about 100,000 gallons. In Vallecitos Valley, the Livermore Gravel and the overlying alluvium constitute the ground-water reservoir. There is no subsurface inflow from adjacent ground-water basins. Ground-water flow in the Vallecitos subbasin is toward the southwest.The proposed network consists of four surface-water sampling sites and six wells to sample the ground-water system. Samples collected monthly at each site and analyzed for tritium and for alpha, beta, and gamma radiation would provide adequate data for monitoring.

  9. The statistical evaluation and comparison of ADMS-Urban model for the prediction of nitrogen dioxide with air quality monitoring network.

    PubMed

    Dėdelė, Audrius; Miškinytė, Auksė

    2015-09-01

    In many countries, road traffic is one of the main sources of air pollution associated with adverse effects on human health and environment. Nitrogen dioxide (NO2) is considered to be a measure of traffic-related air pollution, with concentrations tending to be higher near highways, along busy roads, and in the city centers, and the exceedances are mainly observed at measurement stations located close to traffic. In order to assess the air quality in the city and the air pollution impact on public health, air quality models are used. However, firstly, before the model can be used for these purposes, it is important to evaluate the accuracy of the dispersion modelling as one of the most widely used method. The monitoring and dispersion modelling are two components of air quality monitoring system (AQMS), in which statistical comparison was made in this research. The evaluation of the Atmospheric Dispersion Modelling System (ADMS-Urban) was made by comparing monthly modelled NO2 concentrations with the data of continuous air quality monitoring stations in Kaunas city. The statistical measures of model performance were calculated for annual and monthly concentrations of NO2 for each monitoring station site. The spatial analysis was made using geographic information systems (GIS). The calculation of statistical parameters indicated a good ADMS-Urban model performance for the prediction of NO2. The results of this study showed that the agreement of modelled values and observations was better for traffic monitoring stations compared to the background and residential stations.

  10. [Development of wireless monitoring system based on Zigbee technology in blood and bacterin cold chain].

    PubMed

    Zhao, Peng; Sun, Jian-Jun; Wu, Tai-Hu

    2008-11-01

    Real-time monitoring for temperature is required in cold chain for the medical products that are sensible with temperature, such as blood and bacterin, to guarantee the quality and reduce their wastage. This wireless monitoring system in cold chain is developed with Zigbee technology. Functions such as real-time monitoring, analyzing, alarming are realized. The system boasts such characteristics as low power consumption, low cost, big capacity and high reliability, and could improve the capability of real-time monitoring and management in cold chain effectively.

  11. Copilot: Monitoring Embedded Systems

    NASA Technical Reports Server (NTRS)

    Pike, Lee; Wegmann, Nis; Niller, Sebastian; Goodloe, Alwyn

    2012-01-01

    Runtime verification (RV) is a natural fit for ultra-critical systems, where correctness is imperative. In ultra-critical systems, even if the software is fault-free, because of the inherent unreliability of commodity hardware and the adversity of operational environments, processing units (and their hosted software) are replicated, and fault-tolerant algorithms are used to compare the outputs. We investigate both software monitoring in distributed fault-tolerant systems, as well as implementing fault-tolerance mechanisms using RV techniques. We describe the Copilot language and compiler, specifically designed for generating monitors for distributed, hard real-time systems. We also describe two case-studies in which we generated Copilot monitors in avionics systems.

  12. The Design of an Autonomous Underwater Vehicle for Water Quality Monitoring

    NASA Astrophysics Data System (ADS)

    Li, Yulong; Liu, Rong; Liu, Shujin

    2018-01-01

    This paper describes the development of a civilian-used autonomous underwater vehicle (AUV) for water quality monitoring at reservoirs and watercourses that can obtain realtime visual and locational information. The mechanical design was completed with CAD software Solidworks. Four thrusters—two horizontal and two vertical—on board enable the vehicle to surge, heave, yaw, and pitch. A specialized water sample collection compartment is designed to perform water collection at target locations. The vehicle has a central controller—STM32—and a sub-coordinate controller—Arduino MEGA 2560—that coordinates multiple sensors including an inertial sensor, ultrasonic sensors, etc. Global Navigation Satellite System (GNSS) and the inertial sensor enable the vehicle’s localization. Remote operators monitor and control the vehicle via a host computer system. Operators choose either semi-autonomous mode in which they set target locations or manual mode. The experimental results show that the vehicle is able to perform well in either mode.

  13. A High-Resolution Minimicroscope System for Wireless Real-Time Monitoring.

    PubMed

    Wang, Zongjie; Boddeda, Akash; Parker, Benjamin; Samanipour, Roya; Ghosh, Sanjoy; Menard, Frederic; Kim, Keekyoung

    2018-07-01

    Compact, cost-effective, and high-performance microscope that enables the real-time imaging of cells and lab-on-a-chip devices is highly demanded for cell biology and biomedical engineering. This paper aims to present the design and application of an inexpensive wireless minimicroscope with resolution up to 2592 × 1944 pixels and speed up to 90 f/s. The minimicroscope system was built on a commercial embedded system (Raspberry Pi). We modified a camera module and adopted an inverse dual lens system to obtain the clear field of view and appropriate magnification for tens of micrometer objects. The system was capable of capturing time-lapse images and transferring image data wirelessly. The entire system can be operated wirelessly and cordlessly in a conventional cell culturing incubator. The developed minimicroscope was used to monitor the attachment and proliferation of NIH-3T3 and HEK 293 cells inside an incubator for 50 h. In addition, the minimicroscope was used to monitor a droplet generation process in a microfluidic device. The high-quality images captured by the minimicroscope enabled us an automated analysis of experimental parameters. The successful applications prove the great potential of the developed minimicroscope for monitoring various biological samples and microfluidic devices. This paper presents the design of a high-resolution minimicroscope system that enables the wireless real-time imaging of cells inside the incubator. This system has been verified to be a useful tool to obtain high-quality images and videos for the automated quantitative analysis of biological samples and lab-on-a-chip devices in the long term.

  14. The swiss neonatal quality cycle, a monitor for clinical performance and tool for quality improvement

    PubMed Central

    2013-01-01

    Background We describe the setup of a neonatal quality improvement tool and list which peer-reviewed requirements it fulfils and which it does not. We report on the so-far observed effects, how the units can identify quality improvement potential, and how they can measure the effect of changes made to improve quality. Methods Application of a prospective longitudinal national cohort data collection that uses algorithms to ensure high data quality (i.e. checks for completeness, plausibility and reliability), and to perform data imaging (Plsek’s p-charts and standardized mortality or morbidity ratio SMR charts). The collected data allows monitoring a study collective of very low birth-weight infants born from 2009 to 2011 by applying a quality cycle following the steps ′guideline – perform - falsify – reform′. Results 2025 VLBW live-births from 2009 to 2011 representing 96.1% of all VLBW live-births in Switzerland display a similar mortality rate but better morbidity rates when compared to other networks. Data quality in general is high but subject to improvement in some units. Seven measurements display quality improvement potential in individual units. The methods used fulfil several international recommendations. Conclusions The Quality Cycle of the Swiss Neonatal Network is a helpful instrument to monitor and gradually help improve the quality of care in a region with high quality standards and low statistical discrimination capacity. PMID:24074151

  15. Monitoring surface water quality using social media in the context of citizen science

    NASA Astrophysics Data System (ADS)

    Zheng, Hang; Hong, Yang; Long, Di; Jing, Hua

    2017-02-01

    Surface water quality monitoring (SWQM) provides essential information for water environmental protection. However, SWQM is costly and limited in terms of equipment and sites. The global popularity of social media and intelligent mobile devices with GPS and photography functions allows citizens to monitor surface water quality. This study aims to propose a method for SWQM using social media platforms. Specifically, a WeChat-based application platform is built to collect water quality reports from volunteers, which have been proven valuable for water quality monitoring. The methods for data screening and volunteer recruitment are discussed based on the collected reports. The proposed methods provide a framework for collecting water quality data from citizens and offer a primary foundation for big data analysis in future research.

  16. 40 CFR 75.21 - Quality assurance and quality control requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Quality assurance and quality control... PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Operation and Maintenance Requirements § 75.21 Quality assurance and quality control requirements. (a) Continuous emission monitoring systems. The owner or...

  17. Analysis of long-term water quality for effective river health monitoring in peri-urban landscapes--a case study of the Hawkesbury-Nepean river system in NSW, Australia.

    PubMed

    Pinto, U; Maheshwari, B L; Ollerton, R L

    2013-06-01

    The Hawkesbury-Nepean River (HNR) system in South-Eastern Australia is the main source of water supply for the Sydney Metropolitan area and is one of the more complex river systems due to the influence of urbanisation and other activities in the peri-urban landscape through which it flows. The long-term monitoring of river water quality is likely to suffer from data gaps due to funding cuts, changes in priority and related reasons. Nevertheless, we need to assess river health based on the available information. In this study, we demonstrated how the Factor Analysis (FA), Hierarchical Agglomerative Cluster Analysis (HACA) and Trend Analysis (TA) can be applied to evaluate long-term historic data sets. Six water quality parameters, viz., temperature, chlorophyll-a, dissolved oxygen, oxides of nitrogen, suspended solids and reactive silicates, measured at weekly intervals between 1985 and 2008 at 12 monitoring stations located along the 300 km length of the HNR system were evaluated to understand the human and natural influences on the river system in a peri-urban landscape. The application of FA extracted three latent factors which explained more than 70 % of the total variance of the data and related to the 'bio-geographical', 'natural' and 'nutrient pollutant' dimensions of the HNR system. The bio-geographical and nutrient pollution factors more likely related to the direct influence of changes and activities of peri-urban natures and accounted for approximately 50 % of variability in water quality. The application of HACA indicated two major clusters representing clean and polluted zones of the river. On the spatial scale, one cluster was represented by the upper and lower sections of the river (clean zone) and accounted for approximately 158 km of the river. The other cluster was represented by the middle section (polluted zone) with a length of approximately 98 km. Trend Analysis indicated how the point sources influence river water quality on spatio

  18. INTEGRATING PROBABILISTIC AND FIXED-SITE MONITORING FOR ROBUST WATER QUALITY ASSESSMENTS

    EPA Science Inventory

    Determining the extent of water-quality degradation, controlling nonpoint sources, and defining allowable amounts of contaminants are important water-quality issues defined in the Clean Water Act that require new monitoring data. Probabilistic, randomized stream water-quality mon...

  19. Quality assurance for online adapted treatment plans: benchmarking and delivery monitoring simulation.

    PubMed

    Li, Taoran; Wu, Qiuwen; Yang, Yun; Rodrigues, Anna; Yin, Fang-Fang; Jackie Wu, Q

    2015-01-01

    An important challenge facing online adaptive radiation therapy is the development of feasible and efficient quality assurance (QA). This project aimed to validate the deliverability of online adapted plans and develop a proof-of-concept online delivery monitoring system for online adaptive radiation therapy QA. The first part of this project benchmarked automatically online adapted prostate treatment plans using traditional portal dosimetry IMRT QA. The portal dosimetry QA results of online adapted plans were compared to original (unadapted) plans as well as randomly selected prostate IMRT plans from our clinic. In the second part, an online delivery monitoring system was designed and validated via a simulated treatment with intentional multileaf collimator (MLC) errors. This system was based on inputs from the dynamic machine information (DMI), which continuously reports actual MLC positions and machine monitor units (MUs) at intervals of 50 ms or less during delivery. Based on the DMI, the system performed two levels of monitoring/verification during the delivery: (1) dynamic monitoring of cumulative fluence errors resulting from leaf position deviations and visualization using fluence error maps (FEMs); and (2) verification of MLC positions against the treatment plan for potential errors in MLC motion and data transfer at each control point. Validation of the online delivery monitoring system was performed by introducing intentional systematic MLC errors (ranging from 0.5 to 2 mm) to the DMI files for both leaf banks. These DMI files were analyzed by the proposed system to evaluate the system's performance in quantifying errors and revealing the source of errors, as well as to understand patterns in the FEMs. In addition, FEMs from 210 actual prostate IMRT beams were analyzed using the proposed system to further validate its ability to catch and identify errors, as well as establish error magnitude baselines for prostate IMRT delivery. Online adapted plans were

  20. How Much Will It Cost To Monitor Microbial Drinking Water Quality in Sub-Saharan Africa?

    PubMed Central

    2017-01-01

    Microbial water quality monitoring is crucial for managing water resources and protecting public health. However, institutional testing activities in sub-Saharan Africa are currently limited. Because the economics of water quality testing are poorly understood, the extent to which cost may be a barrier to monitoring in different settings is unclear. This study used cost data from 18 African monitoring institutions (piped water suppliers and health surveillance agencies in six countries) and estimates of water supply type coverage from 15 countries to assess the annual financial requirements for microbial water testing at both national and regional levels, using World Health Organization recommendations for sampling frequency. We found that a microbial water quality test costs 21.0 ± 11.3 USD, on average, including consumables, equipment, labor, and logistics, which is higher than previously calculated. Our annual cost estimates for microbial monitoring of piped supplies and improved point sources ranged between 8 000 USD for Equatorial Guinea and 1.9 million USD for Ethiopia, depending primarily on the population served but also on the distribution of piped water system sizes. A comparison with current national water and sanitation budgets showed that the cost of implementing prescribed testing levels represents a relatively modest proportion of existing budgets (<2%). At the regional level, we estimated that monitoring the microbial quality of all improved water sources in sub-Saharan Africa would cost 16.0 million USD per year, which is minimal in comparison to the projected annual capital costs of achieving Sustainable Development Goal 6.1 of safe water for all (14.8 billion USD). PMID:28459563

  1. Near real time water quality monitoring of Chivero and Manyame lakes of Zimbabwe

    NASA Astrophysics Data System (ADS)

    Muchini, Ronald; Gumindoga, Webster; Togarepi, Sydney; Pinias Masarira, Tarirai; Dube, Timothy

    2018-05-01

    Zimbabwe's water resources are under pressure from both point and non-point sources of pollution hence the need for regular and synoptic assessment. In-situ and laboratory based methods of water quality monitoring are point based and do not provide a synoptic coverage of the lakes. This paper presents novel methods for retrieving water quality parameters in Chivero and Manyame lakes, Zimbabwe, from remotely sensed imagery. Remotely sensed derived water quality parameters are further validated using in-situ data. It also presents an application for automated retrieval of those parameters developed in VB6, as well as a web portal for disseminating the water quality information to relevant stakeholders. The web portal is developed, using Geoserver, open layers and HTML. Results show the spatial variation of water quality and an automated remote sensing and GIS system with a web front end to disseminate water quality information.

  2. Applications of MODIS satellite data and products for monitoring air quality in the state of Texas

    NASA Astrophysics Data System (ADS)

    Hutchison, Keith D.

    The Center for Space Research (CSR), in conjunction with the Monitoring Operations Division (MOD) of the Texas Commission on Environmental Quality (TCEQ), is evaluating the use of remotely sensed satellite data to assist in monitoring and predicting air quality in Texas. The challenges of meeting air quality standards established by the US Environmental Protection Agency (US EPA) are impacted by the transport of pollution into Texas that originates from outside our borders and are cumulative with those generated by local sources. In an attempt to quantify the concentrations of all pollution sources, MOD has installed ground-based monitoring stations in rural regions along the Texas geographic boundaries including the Gulf coast, as well as urban regions that are the predominant sources of domestic pollution. However, analysis of time-lapse GOES satellite imagery at MOD, clearly demonstrates the shortcomings of using only ground-based observations for monitoring air quality across Texas. These shortcomings include the vastness of State borders, that can only be monitored with a large number of ground-based sensors, and gradients in pollution concentration that depend upon the location of the point source, the meteorology governing its transport to Texas, and its diffusion across the region. With the launch of NASA's MODerate resolution Imaging Spectroradiometer (MODIS), the transport of aerosol-borne pollutants can now be monitored over land and ocean surfaces. Thus, CSR and MOD personnel have applied MODIS data to several classes of pollution that routinely impact Texas air quality. Results demonstrate MODIS data and products can detect and track the migration of pollutants. This paper presents one case study in which continental haze from the northeast moved into the region and subsequently required health advisories to be issued for 150 counties in Texas. It is concluded that MODIS provides the basis for developing advanced data products that will, when used in

  3. SprayQc: a real-time LC-MS/MS quality monitoring system to maximize uptime using off the shelf components.

    PubMed

    Scheltema, Richard A; Mann, Matthias

    2012-06-01

    With the advent of high-throughput mass spectrometry (MS)-based proteomics, the magnitude and complexity of the performed experiments has increased dramatically. Likewise, investments in chromatographic and MS instrumentation are a large proportion of the budget of proteomics laboratories. Guarding measurement quality and maximizing uptime of the LC-MS/MS systems therefore requires constant care despite automated workflows. We describe a real-time surveillance system, called SprayQc, that continuously monitors the status of the peripheral equipment to ensure that operational parameters are within an acceptable range. SprayQc is composed of multiple plug-in software components that use computer vision to analyze electrospray conditions, monitor the chromatographic device for stable backpressure, interact with a column oven to control pressure by temperature, and ensure that the mass spectrometer is still acquiring data. Action is taken when a failure condition has been detected, such as stopping the column oven and the LC flow, as well as automatically notifying the appropriate operator. Additionally, all defined metrics can be recorded synchronized on retention time with the MS acquisition file, allowing for later inspection and providing valuable information for optimization. SprayQc has been extensively tested in our laboratory, supports third-party plug-in development, and is freely available for download from http://sourceforge.org/projects/sprayqc .

  4. Automated water monitor system field demonstration test report. Volume 2: Technical summary

    NASA Technical Reports Server (NTRS)

    Brooks, R. L.; Jeffers, E. L.; Perreira, J.; Poel, J. D.; Nibley, D.; Nuss, R. H.

    1981-01-01

    The NASA Automatic Water Monitor System was installed in a water reclamation facility to evaluate the technical and cost feasibility of producing high quality reclaimed water. Data gathered during this field demonstration test are reported.

  5. A Wireless Physiological Signal Monitoring System with Integrated Bluetooth and WiFi Technologies.

    PubMed

    Yu, Sung-Nien; Cheng, Jen-Chieh

    2005-01-01

    This paper proposes a wireless patient monitoring system which integrates Bluetooth and WiFi wireless technologies. A wireless portable multi-parameter device was designated to acquire physiological signals and transmit them to a local server via Bluetooth wireless technology. Four kinds of monitor units were designed to communicate via the WiFi wireless technology, including a local monitor unit, a control center, mobile devices (personal digital assistant; PDA), and a web page. The use of various monitor units is intending to meet different medical requirements for different medical personnel. This system was demonstrated to promote the mobility and flexibility for both the patients and the medical personnel, which further improves the quality of health care.

  6. Data quality through a web-based QA/QC system: implementation for atmospheric mercury data from the global mercury observation system.

    PubMed

    D'Amore, Francesco; Bencardino, Mariantonia; Cinnirella, Sergio; Sprovieri, Francesca; Pirrone, Nicola

    2015-08-01

    The overall goal of the on-going Global Mercury Observation System (GMOS) project is to develop a coordinated global monitoring network for mercury, including ground-based, high altitude and sea level stations. In order to ensure data reliability and comparability, a significant effort has been made to implement a centralized system, which is designed to quality assure and quality control atmospheric mercury datasets. This system, GMOS-Data Quality Management (G-DQM), uses a web-based approach with real-time adaptive monitoring procedures aimed at preventing the production of poor-quality data. G-DQM is plugged on a cyberinfrastructure and deployed as a service. Atmospheric mercury datasets, produced during the first-three years of the GMOS project, are used as the input to demonstrate the application of the G-DQM and how it identifies a number of key issues concerning data quality. The major issues influencing data quality are presented and discussed for the GMOS stations under study. Atmospheric mercury data collected at the Longobucco (Italy) station is used as a detailed case study.

  7. Expert Systems for Real-Time Volcano Monitoring

    NASA Astrophysics Data System (ADS)

    Cassisi, C.; Cannavo, F.; Montalto, P.; Motta, P.; Schembra, G.; Aliotta, M. A.; Cannata, A.; Patanè, D.; Prestifilippo, M.

    2014-12-01

    In the last decade, the capability to monitor and quickly respond to remote detection of volcanic activity has been greatly improved through use of advanced techniques and semi-automatic software applications installed in most of the 24h control rooms devoted to volcanic surveillance. Ability to monitor volcanoes is being advanced by new technology, such as broad-band seismology, microphone networks mainly recording in the infrasonic frequency band, satellite observations of ground deformation, high quality video surveillance systems, also in infrared band, improved sensors for volcanic gas measurements, and advances in computer power and speed, leading to improvements in data transmission, data analysis and modeling techniques. One of the most critical point in the real-time monitoring chain is the evaluation of the volcano state from all the measurements. At the present, most of this task is delegated to one or more human experts in volcanology. Unfortunately, the volcano state assessment becomes harder if we observe that, due to the coupling of highly non-linear and complex volcanic dynamic processes, the measurable effects can show a rich range of different behaviors. Moreover, due to intrinsic uncertainties and possible failures in some recorded data, precise state assessment is usually not achievable. Hence, the volcano state needs to be expressed in probabilistic terms that take account of uncertainties. In the framework of the project PON SIGMA (Integrated Cloud-Sensor System for Advanced Multirisk Management) work, we have developed an expert system approach to estimate the ongoing volcano state from all the available measurements and with minimal human interaction. The approach is based on hidden markov model and deals with uncertainties and probabilities. We tested the proposed approach on data coming from the Mt. Etna (Italy) continuous monitoring networks for the period 2011-2013. Results show that this approach can be a valuable tool to aid the

  8. airborne data analysis/monitor system

    NASA Technical Reports Server (NTRS)

    Stephison, D. B.

    1981-01-01

    An Airborne Data Analysis/Monitor System (ADAMS), a ROLM 1666 computer based system installed onboard test airplanes used during experimental testing is evaluated. In addition to the 1666 computer, the ADAMS hardware includes a DDC System 90 fixed head disk and a Miltape DD400 floppy disk. Boeing designed a DMA interface to the data acquisition system and an intelligent terminal to reduce system overhead and simplify operator commands. The ADAMS software includes RMX/RTOS and both ROLM FORTRAN and assembly language are used. The ADAMS provides real time displays that enable onboard test engineers to make rapid decisions about test conduct thus reducing the cost and time required to certify new model airplanes, and improved the quality of data derived from the test, leading to more rapid development of improvements resulting in quieter, safer, and more efficient airplanes. The availability of airborne data processing removes most of the weather and geographical restrictions imposed by telemetered flight test data systems. A data base is maintained to describe the airplane, the data acquisition system, the type of testing, and the conditions under which the test is performed.

  9. Lot quality assurance sampling to monitor supplemental immunization activity quality: an essential tool for improving performance in polio endemic countries.

    PubMed

    Brown, Alexandra E; Okayasu, Hiromasa; Nzioki, Michael M; Wadood, Mufti Z; Chabot-Couture, Guillaume; Quddus, Arshad; Walker, George; Sutter, Roland W

    2014-11-01

    Monitoring the quality of supplementary immunization activities (SIAs) is a key tool for polio eradication. Regular monitoring data, however, are often unreliable, showing high coverage levels in virtually all areas, including those with ongoing virus circulation. To address this challenge, lot quality assurance sampling (LQAS) was introduced in 2009 as an additional tool to monitor SIA quality. Now used in 8 countries, LQAS provides a number of programmatic benefits: identifying areas of weak coverage quality with statistical reliability, differentiating areas of varying coverage with greater precision, and allowing for trend analysis of campaign quality. LQAS also accommodates changes to survey format, interpretation thresholds, evaluations of sample size, and data collection through mobile phones to improve timeliness of reporting and allow for visualization of campaign quality. LQAS becomes increasingly important to address remaining gaps in SIA quality and help focus resources on high-risk areas to prevent the continued transmission of wild poliovirus. © Crown copyright 2014.

  10. myBrain: a novel EEG embedded system for epilepsy monitoring.

    PubMed

    Pinho, Francisco; Cerqueira, João; Correia, José; Sousa, Nuno; Dias, Nuno

    2017-10-01

    The World Health Organisation has pointed that a successful health care delivery, requires effective medical devices as tools for prevention, diagnosis, treatment and rehabilitation. Several studies have concluded that longer monitoring periods and outpatient settings might increase diagnosis accuracy and success rate of treatment selection. The long-term monitoring of epileptic patients through electroencephalography (EEG) has been considered a powerful tool to improve the diagnosis, disease classification, and treatment of patients with such condition. This work presents the development of a wireless and wearable EEG acquisition platform suitable for both long-term and short-term monitoring in inpatient and outpatient settings. The developed platform features 32 passive dry electrodes, analogue-to-digital signal conversion with 24-bit resolution and a variable sampling frequency from 250 Hz to 1000 Hz per channel, embedded in a stand-alone module. A computer-on-module embedded system runs a Linux ® operating system that rules the interface between two software frameworks, which interact to satisfy the real-time constraints of signal acquisition as well as parallel recording, processing and wireless data transmission. A textile structure was developed to accommodate all components. Platform performance was evaluated in terms of hardware, software and signal quality. The electrodes were characterised through electrochemical impedance spectroscopy and the operating system performance running an epileptic discrimination algorithm was evaluated. Signal quality was thoroughly assessed in two different approaches: playback of EEG reference signals and benchmarking with a clinical-grade EEG system in alpha-wave replacement and steady-state visual evoked potential paradigms. The proposed platform seems to efficiently monitor epileptic patients in both inpatient and outpatient settings and paves the way to new ambulatory clinical regimens as well as non-clinical EEG

  11. New Quality Control Algorithm Based on GNSS Sensing Data for a Bridge Health Monitoring System.

    PubMed

    Lee, Jae Kang; Lee, Jae One; Kim, Jung Ok

    2016-05-27

    This research introduces an improvement plan for the reliability of Global Navigation Satellite System (GNSS) positioning solutions. It should be considered the most suitable methodology in terms of the adjustment and positioning of GNSS in order to maximize the utilization of GNSS applications. Though various studies have been conducted with regards to Bridge Health Monitoring System (BHMS) based on GNSS, the outliers which depend on the signal reception environment could not be considered until now. Since these outliers may be connected to GNSS data collected from major bridge members, which can reduce the reliability of a whole monitoring system through the delivery of false information, they should be detected and eliminated in the previous adjustment stage. In this investigation, the Detection, Identification, Adaptation (DIA) technique was applied and implemented through an algorithm. Moreover, it can be directly applied to GNSS data collected from long span cable stayed bridges and most of outliers were efficiently detected and eliminated simultaneously. By these effects, the reliability of GNSS should be enormously improved. Improvement on GNSS positioning accuracy is directly linked to the safety of bridges itself, and at the same time, the reliability of monitoring systems in terms of the system operation can also be increased.

  12. New Quality Control Algorithm Based on GNSS Sensing Data for a Bridge Health Monitoring System

    PubMed Central

    Lee, Jae Kang; Lee, Jae One; Kim, Jung Ok

    2016-01-01

    This research introduces an improvement plan for the reliability of Global Navigation Satellite System (GNSS) positioning solutions. It should be considered the most suitable methodology in terms of the adjustment and positioning of GNSS in order to maximize the utilization of GNSS applications. Though various studies have been conducted with regards to Bridge Health Monitoring System (BHMS) based on GNSS, the outliers which depend on the signal reception environment could not be considered until now. Since these outliers may be connected to GNSS data collected from major bridge members, which can reduce the reliability of a whole monitoring system through the delivery of false information, they should be detected and eliminated in the previous adjustment stage. In this investigation, the Detection, Identification, Adaptation (DIA) technique was applied and implemented through an algorithm. Moreover, it can be directly applied to GNSS data collected from long span cable stayed bridges and most of outliers were efficiently detected and eliminated simultaneously. By these effects, the reliability of GNSS should be enormously improved. Improvement on GNSS positioning accuracy is directly linked to the safety of bridges itself, and at the same time, the reliability of monitoring systems in terms of the system operation can also be increased. PMID:27240375

  13. MAINTAINING DATA QUALITY IN THE PERFORMANCE OF A LARGE SCALE INTEGRATED MONITORING EFFORT

    EPA Science Inventory

    Macauley, John M. and Linda C. Harwell. In press. Maintaining Data Quality in the Performance of a Large Scale Integrated Monitoring Effort (Abstract). To be presented at EMAP Symposium 2004: Integrated Monitoring and Assessment for Effective Water Quality Management, 3-7 May 200...

  14. Interpreting drinking water quality in the distribution system using Dempster-Shafer theory of evidence.

    PubMed

    Sadiq, Rehan; Rodriguez, Manuel J

    2005-04-01

    Interpreting water quality data routinely generated for control and monitoring purposes in water distribution systems is a complicated task for utility managers. In fact, data for diverse water quality indicators (physico-chemical and microbiological) are generated at different times and at different locations in the distribution system. To simplify and improve the understanding and the interpretation of water quality, methodologies for aggregation and fusion of data must be developed. In this paper, the Dempster-Shafer theory also called theory of evidence is introduced as a potential methodology for interpreting water quality data. The conceptual basis of this methodology and the process for its implementation are presented by two applications. The first application deals with the interpretation of spatial water quality data fusion, while the second application deals with the development of water quality index based on key monitored indicators. Based on the obtained results, the authors discuss the potential contribution of theory of evidence as a decision-making tool for water quality management.

  15. Biomedical wellness monitoring system based upon molecular markers

    NASA Astrophysics Data System (ADS)

    Ingram, Whitney

    2012-06-01

    We wish to assist caretakers with a sensor monitoring systems for tracking the physiological changes of homealone patients. One goal is seeking biomarkers and modern imaging sensors like stochastic optical reconstruction microscopy (STORM), which has achieved visible imaging at the nano-scale range. Imaging techniques like STORM can be combined with a fluorescent functional marker in a system to capture the early transformation signs from wellness to illness. By exploiting both microscopic knowledge of genetic pre-disposition and the macroscopic influence of epigenetic factors we hope to target these changes remotely. We adopt dual spectral infrared imaging for blind source separation (BSS) to detect angiogenesis changes and use laser speckle imaging for hypertension blood flow monitoring. Our design hypothesis for the monitoring system is guided by the user-friendly, veteran-preferred "4-Non" principles (noninvasive, non-contact, non-tethered, non-stop-to-measure) and by the NIH's "4Ps" initiatives (predictive, personalized, preemptive, and participatory). We augment the potential storage system with the recent know-how of video Compressive Sampling (CSp) from surveillance cameras. In CSp only major changes are saved, which reduces the manpower cost of caretakers and medical analysts. This CSp algorithm is based on smart associative memory (AM) matrix storage: change features and detailed scenes are written by the outer-product and read by the inner product without the usual Harsh index for image searching. From this approach, we attempt to design an effective household monitoring approach to save healthcare costs and maintain the quality of life of seniors.

  16. Curriculum-Based Measurement of Oral Reading: Quality of Progress Monitoring Outcomes

    ERIC Educational Resources Information Center

    Christ, Theodore J.; Zopluoglu, Cengiz; Long, Jeffery D.; Monaghen, Barbara D.

    2012-01-01

    Curriculum-based measurement of oral reading (CBM-R) is frequently used to set student goals and monitor student progress. This study examined the quality of growth estimates derived from CBM-R progress monitoring data. The authors used a linear mixed effects regression (LMER) model to simulate progress monitoring data for multiple levels of…

  17. A socio-environmental monitoring system for a UNESCO biosphere reserve.

    PubMed

    Lowell, Kim

    2017-11-03

    To identify potentially critical changes in an area's ongoing ability to produce multiple ecosystem services, a monitoring system was designed and implemented for the Mornington Peninsula and Westernport Biosphere Reserve in southeast Australia. The system is underpinned by an "environmental vital signs" (EVS) approach that was adopted to provide early warning of critical changes in human and natural characteristics of the area. The six themes monitored are non-coastal water, land including vegetation, biodiversity, natural heritage, built environment (including human population and economic activity), and coasts. These are monitored for the entire area, and each of its five constituent town council areas. After a critical change in any of these is identified, further investigation is required to identify causal factors and, if required, determine an appropriate response. The system relies on data available from external (third-party) organisations to monitor the natural and human characteristics of the area that were important in its designation as a UNESCO biosphere reserve. Strengths and weaknesses associated with the use of third-party data are discussed. These include adoption of baseline years and data reporting periods for different factors, costs, and data quality.

  18. Physiologic monitoring. A guide to networking your monitoring systems.

    PubMed

    2011-10-01

    There are many factors to consider when choosing a physiologic monitoring system. not only should these systems perform well clinically, but they should also be able to exchange data with other information systems. We discuss some of the ins and outs of physiologic monitoring system networking and highlight eight product lines from seven suppliers.

  19. Quality monitoring of salt produced in Indonesia through seawater evaporation on HDPE geomembrane lined ponds

    NASA Astrophysics Data System (ADS)

    Jumaeri; Sulistyaningsih, T.; Alighiri, D.

    2018-03-01

    Salt is one of the primary ingredients that humans always need for various purposes, both for consumption and industry. The need for high-quality salt continues to increase, as long as industry growth. It must improve product quality through the development of salt production process technology. In this research, the quality monitoring of salt produced in Indonesia by evaporation of seawater on ponds lined using high-density polyethylene (HDPE) geomembrane has been studied. The manufacturing of salt carried out through the gradual precipitation principle on prepared ponds. HDPE geomembrane is used to coat evaporation ponds with viscosity 12-22°Be and crystallization ponds with a viscosity of 23°Be. The monitoring of the product is carried out in the particular periods during the salt production period. The result of control shows that the quality of salt produced in HDPE geomembrane coated salt ponds has an average NaCl content of 95.75%, so it has fulfilled with Indonesia National Standard (SNI), that is NaCl> 94.70%. The production of salt with HDPE geomembrane can improve the quality of salt product from NaCl 85.4% (conventional system) to 95.75%.

  20. Location and site characteristics of the ambient ground-water-quality-monitoring network in West Virginia

    USGS Publications Warehouse

    Kozar, M.D.; Brown, D.P.

    1995-01-01

    Ground-water-quality-monitoring sites have been established in compliance with the 1991 West Virginia "Groundwater Protection Act." One of the provisions of the "Groundwater Protection Act" is to conduct ground-water sampling, data collection, analyses, and evaluation with sufficient frequency so as to ascertain the characteristics and quality of ground water and the sufficiency of the ground- water protection programs established pursuant to the act (Chapter 20 of the code of West Virginia, 1991, Article 5-M). Information for 26 monitoring sites (wells and springs) which comprise the Statewide ambient ground-water-quality-monitoring network is presented. Areas in which monitoring sites were needed were determined by the West Virginia Division of Environmental Protection, Office of Water Resources in consultation with the U.S. Geological Survey (USGS). Initial sites were chosen on the basis of recent hydrogeologic investigations conducted by the USGS and from data stored in the USGS Ground Water Site Inventory database. Land use, aquifer setting, and areal coverage of the State are three of the more important criteria used in site selection. A field reconnaissance was conducted to locate and evaluate the adequacy of selected wells and springs. Descriptive information consisting of site, geologic, well construction, and aquifer-test data has been compiled. The 26 sites will be sampled periodically for iron, manganese, most common ions (for example, calcium, magnesium, sodium, potassium, sulfate, chloride, bicarbonate), volatile and semivolatile organic compounds (for example, pesticides and industrial solvents), and fecal coliform and fecal streptococcus bacteria. Background information explaining ground-water systems and water quality within the State has been included.

  1. Apparatus and method for acoustic monitoring of steam quality and flow

    DOEpatents

    Sinha, Dipen N.; Pantea, Cristian

    2016-09-13

    An apparatus and method for noninvasively monitoring steam quality and flow and in pipes or conduits bearing flowing steam, are described. By measuring the acoustic vibrations generated in steam-carrying conduits by the flowing steam either by direct contact with the pipe or remotely thereto, converting the measured acoustic vibrations into a frequency spectrum characteristic of the natural resonance vibrations of the pipe, and monitoring the amplitude and/or the frequency of one or more chosen resonance frequencies, changes in the steam quality in the pipe are determined. The steam flow rate and the steam quality are inversely related, and changes in the steam flow rate are calculated from changes in the steam quality once suitable calibration curves are obtained.

  2. Triangle area water supply monitoring project, October 1988 through September 2001, North Carolina -- description of the water-quality network, sampling and analysis methods, and quality-assurance practices

    USGS Publications Warehouse

    Oblinger, Carolyn J.

    2004-01-01

    The Triangle Area Water Supply Monitoring Project was initiated in October 1988 to provide long-term water-quality data for six area water-supply reservoirs and their tributaries. In addition, the project provides data that can be used to determine the effectiveness of large-scale changes in water-resource management practices, document differences in water quality among water-supply types (large multiuse reservoir, small reservoir, run-of-river), and tributary-loading and in-lake data for water-quality modeling of Falls and Jordan Lakes. By September 2001, the project had progressed in four phases and included as many as 34 sites (in 1991). Most sites were sampled and analyzed by the U.S. Geological Survey. Some sites were already a part of the North Carolina Division of Water Quality statewide ambient water-quality monitoring network and were sampled by the Division of Water Quality. The network has provided data on streamflow, physical properties, and concentrations of nutrients, major ions, metals, trace elements, chlorophyll, total organic carbon, suspended sediment, and selected synthetic organic compounds. Project quality-assurance activities include written procedures for sample collection, record management and archive, collection of field quality-control samples (blank samples and replicate samples), and monitoring the quality of field supplies. In addition to project quality-assurance activities, the quality of laboratory analyses was assessed through laboratory quality-assurance practices and an independent laboratory quality-control assessment provided by the U.S. Geological Survey Branch of Quality Systems through the Blind Inorganic Sample Project and the Organic Blind Sample Project.

  3. Soil quality monitoring in an area with land use change

    NASA Astrophysics Data System (ADS)

    Wilson, Marcelo; Gabioud, Emmanuel; Sasal, María Carolina; Oszust, José; Paz Gonzalez, Antonio

    2013-04-01

    The characterization of the soil quality through soil quality indicators (SQI), provides an effective method for the monitoring of the impacts to soil by use and management decisions. The key is to identify variables that are sensitive to changes in the soil functions and processes. The native forest area of Entre Ríos (Argentina) is associated with a constant change in land use, with an increase in recent years in agricultural use, especially for soybean crop. The aim was to monitor soil quality in three soils of an area of this area where native forest is being replaced by an agricultural system based in soybean crop, using a a minimum data set (MDS) previously selected for three soil type. The three soils selected were a Vertic Argiudoll, an Aquic Argiudoll and a Vertic Ocracualf. Treatments included plots with continuous cropping with different number of years under soybean crop, crop-pasture rotation, long-term pasture (PP), and uncropped land (UC) in pristine situation, which was taken as a reference. The crops were sowed under no tillage system and some plots were systematized with terraces contour to runoff management. The selection of a group of soil indicators in a MDS, was developed locally because it must be different for each soil type and each particular use. Total organic carbon (TOC), aggregate stability and pH were common indicators. Furthermore, it was assessed macroporosity, total porosity, cation exchange capacity two biological indicators (microbial biomass Carbon and potentially mineralizable Nitrogen) and A horizon soil mass, as a measure of the soil erosion. Statistical analysis, as linear regression analysis, ANOVA and cluster analysis were used. The soil indicators showed the changes caused by soil use, being more marked deterioration in the Vertic Ocracualf. TOC, microbial biomass Carbon and aggregate stability were the most sensitive SQI. However, positive changes were observed in potentially mineralizable Nitrogen, wiht PP. In the

  4. 29 CFR 1954.2 - Monitoring system.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 9 2014-07-01 2014-07-01 false Monitoring system. 1954.2 Section 1954.2 Labor Regulations...) PROCEDURES FOR THE EVALUATION AND MONITORING OF APPROVED STATE PLANS General § 1954.2 Monitoring system. (a... Act, the Assistant Secretary has established a State Program Performance Monitoring System. Evaluation...

  5. 29 CFR 1954.2 - Monitoring system.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 9 2013-07-01 2013-07-01 false Monitoring system. 1954.2 Section 1954.2 Labor Regulations...) PROCEDURES FOR THE EVALUATION AND MONITORING OF APPROVED STATE PLANS General § 1954.2 Monitoring system. (a... Act, the Assistant Secretary has established a State Program Performance Monitoring System. Evaluation...

  6. 29 CFR 1954.2 - Monitoring system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 9 2012-07-01 2012-07-01 false Monitoring system. 1954.2 Section 1954.2 Labor Regulations...) PROCEDURES FOR THE EVALUATION AND MONITORING OF APPROVED STATE PLANS General § 1954.2 Monitoring system. (a... Act, the Assistant Secretary has established a State Program Performance Monitoring System. Evaluation...

  7. 29 CFR 1954.2 - Monitoring system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 9 2010-07-01 2010-07-01 false Monitoring system. 1954.2 Section 1954.2 Labor Regulations...) PROCEDURES FOR THE EVALUATION AND MONITORING OF APPROVED STATE PLANS General § 1954.2 Monitoring system. (a... Act, the Assistant Secretary has established a State Program Performance Monitoring System. Evaluation...

  8. 29 CFR 1954.2 - Monitoring system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 9 2011-07-01 2011-07-01 false Monitoring system. 1954.2 Section 1954.2 Labor Regulations...) PROCEDURES FOR THE EVALUATION AND MONITORING OF APPROVED STATE PLANS General § 1954.2 Monitoring system. (a... Act, the Assistant Secretary has established a State Program Performance Monitoring System. Evaluation...

  9. Wrist ambulatory monitoring system and smart glove for real time emotional, sensorial and physiological analysis.

    PubMed

    Axisa, F; Gehin, C; Delhomme, G; Collet, C; Robin, O; Dittmar, A

    2004-01-01

    Improvement of the quality and efficiency of the quality of health in medicine, at home and in hospital becomes more and more important Designed to be user-friendly, smart clothes and gloves fit well for such a citizen use and health monitoring. Analysis of the autonomic nervous system using non-invasive sensors provides information for the emotional, sensorial, cognitive and physiological analysis. MARSIAN (modular autonomous recorder system for the measurement of autonomic nervous system) is a wrist ambulatory monitoring and recording system with a smart glove with sensors for the detection of the activity of the autonomic nervous system. It is composed of a "smart tee shirt", a "smart glove", a wrist device and PC which records data. The smart glove is one of the key point of MARSIAN. Complex movements, complex geometry, sensation make smart glove designing a challenge. MARSIAN has a large field of applications and researches (vigilance, behaviour, sensorial analysis, thermal environment for human, cognition science, sport, etc...) in various fields like neurophysiology, affective computing and health monitoring.

  10. How Can Remote Sensing Be Used for Water Quality Monitoring?

    EPA Science Inventory

    “How can remote sensing address information needs and gaps in water quality and quantity management?” was a workshop convened during the biennial National Water Quality Monitoring Conference 2014, held in Cincinnati, OH. The focus of this workshop was to provide an o...

  11. Arduino Based Infant Monitoring System

    NASA Astrophysics Data System (ADS)

    Farhanah Mohamad Ishak, Daing Noor; Jamil, Muhammad Mahadi Abdul; Ambar, Radzi

    2017-08-01

    This paper proposes a system for monitoring infant in an incubator and records the relevant data into a computer. The data recorded by the system can be further referred by the neonatal intensive care unit (NICU) personnel for diagnostic or research purposes. The study focuses on designing the monitoring system that consists of an incubator equipped with humidity sensor to measure the humidity level, and a pulse sensor that can be attached on an infant placed inside the incubator to monitor infant’s heart pulse. The measurement results which are the pulse rate and humidity level are sent to the PC via Arduino microcontroller. The advantage of this system will be that in the future, it may also enable doctors to closely monitor the infant condition through local area network and internet. This work is aimed as an example of an application that contributes towards remote tele-health monitoring system.

  12. Evaluation of the Monitor-CTA Automatic Vehicle Monitoring System

    DOT National Transportation Integrated Search

    1974-03-01

    In June 1972 the Urban Mass Transportation Administration requested that the Transportation System Center of DOT perform an evaluation of the CTA (Chicago Transit Authority) Monitor-Automatic Vehicle Monitor (AVM) system. TSC planned the overall eval...

  13. Lessons from monitoring water quality in San Francisco Bay

    USGS Publications Warehouse

    Cloern, J.E.; Schraga, T.S.; Lopez, C.B.; Labiosa, R.

    2003-01-01

    Bay Area residents feel a sense of responsibility to protect San Francisco Bay and keep it healthy. Some even dream about the recovery of fish stocks so they can sustain commercial fishing once again inside the Bay. How is our Bay doing? Is it highly polluted or pretty clean? How does its health compare with other estuaries in the United States? Are things getting better or worse? Does costly wastewater treatment have benefits? What are the biggest threats to the Bay and how can we reduce or eliminate those threats? How will the Bay change in the future? These questions can only be answered with investments in study and monitoring, and they are the driving force behind the Regional Monitoring Program (RMP). We describe here some selected results from water quality surveillance conducted by the U.S. Geological Survey (USGS) as one component of the RMP. We present results as lessons about how the Bay works as a complex dynamic system, and we show how these lessons are relevant to the broad RMP objectives supporting Bay protection and management.

  14. Development and Application of a Next Generation Air Sensor Network for the Hong Kong Marathon 2015 Air Quality Monitoring.

    PubMed

    Sun, Li; Wong, Ka Chun; Wei, Peng; Ye, Sheng; Huang, Hao; Yang, Fenhuan; Westerdahl, Dane; Louie, Peter K K; Luk, Connie W Y; Ning, Zhi

    2016-02-05

    This study presents the development and evaluation of a next generation air monitoring system with both laboratory and field tests. A multi-parameter algorithm was used to correct for the impact of environmental conditions on the electrochemical sensors for carbon monoxide (CO) and nitrogen dioxide (NO2) pollutants. The field evaluation in an urban roadside environment in comparison to designated monitors showed good agreement with measurement error within 5% of the pollutant concentrations. Multiple sets of the developed system were then deployed in the Hong Kong Marathon 2015 forming a sensor-based network along the marathon route. Real-time air pollution concentration data were wirelessly transmitted and the Air Quality Health Index (AQHI) for the Green Marathon was calculated, which were broadcast to the public on an hourly basis. The route-specific sensor network showed somewhat different pollutant patterns than routine air monitoring, indicating the immediate impact of traffic control during the marathon on the roadside air quality. The study is one of the first applications of a next generation sensor network in international sport events, and it demonstrated the usefulness of the emerging sensor-based air monitoring technology in rapid network deployment to supplement existing air monitoring.

  15. Enhanced data validation strategy of air quality monitoring network.

    PubMed

    Harkat, Mohamed-Faouzi; Mansouri, Majdi; Nounou, Mohamed; Nounou, Hazem

    2018-01-01

    Quick validation and detection of faults in measured air quality data is a crucial step towards achieving the objectives of air quality networks. Therefore, the objectives of this paper are threefold: (i) to develop a modeling technique that can be used to predict the normal behavior of air quality variables and help provide accurate reference for monitoring purposes; (ii) to develop fault detection method that can effectively and quickly detect any anomalies in measured air quality data. For this purpose, a new fault detection method that is based on the combination of generalized likelihood ratio test (GLRT) and exponentially weighted moving average (EWMA) will be developed. GLRT is a well-known statistical fault detection method that relies on maximizing the detection probability for a given false alarm rate. In this paper, we propose to develop GLRT-based EWMA fault detection method that will be able to detect the changes in the values of certain air quality variables; (iii) to develop fault isolation and identification method that allows defining the fault source(s) in order to properly apply appropriate corrective actions. In this paper, reconstruction approach that is based on Midpoint-Radii Principal Component Analysis (MRPCA) model will be developed to handle the types of data and models associated with air quality monitoring networks. All air quality modeling, fault detection, fault isolation and reconstruction methods developed in this paper will be validated using real air quality data (such as particulate matter, ozone, nitrogen and carbon oxides measurement). Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Considerations for monitoring water quality of the Schenectady aquifer, Schenectady County, New York

    USGS Publications Warehouse

    Allen, R.V.; Waller, Roger Milton

    1981-01-01

    Six public water-supply systems in Schenectady County, N.Y., obtain water from sand and gravel units that form a more or less continuous aquifer system contiguous to the Mohawk River. The aquifer is under water-table conditions and in hydraulic contact with the river, so that pumping wells induces recharge from the river. Direct recharge to the aquifer from precipitation and runoff occurs throughout the valley floor. Chemical analyses since 1972 have indicated no water-quality deterioration from toxic substances, including pesticides. Geohydrologic conditions at each of the six well fields were evaluated to determine the feasibility of a monitoring system to provide warning of contamination before it reaches a pumping center. Potential contamination sources in the area are landfills, gravel pits, industrial sites, and transportation corridors. Only two of the well fields have wells that could be used for monitoring; at most sites, two or more wells would need to be installed to provide minimal means of detecting contaminants migrating toward a pumping center. (USGS)

  17. A multiyear quality control study of alpha-track radon monitors.

    PubMed

    Pearson, M D; Martz, D E; George, J L; Langner, G H

    1992-01-01

    Quality control exposures of commercial alpha-track radon monitors have been conducted approximately weekly at the U.S. Department of Energy (DOE) Grand Junction Projects Office since early 1987 in support of DOE remedial action programs. The results of these exposures provide a historical record of the comparative performances of these radon monitors.

  18. Canadian Operational Air Quality Forecasting Systems: Status, Recent Progress, and Challenges

    NASA Astrophysics Data System (ADS)

    Pavlovic, Radenko; Davignon, Didier; Ménard, Sylvain; Munoz-Alpizar, Rodrigo; Landry, Hugo; Beaulieu, Paul-André; Gilbert, Samuel; Moran, Michael; Chen, Jack

    2017-04-01

    ECCC's Canadian Meteorological Centre Operations (CMCO) division runs a number of operational air quality (AQ)-related systems that revolve around the Regional Air Quality Deterministic Prediction System (RAQDPS). The RAQDPS generates 48-hour AQ forecasts and outputs hourly concentration fields of O3, PM2.5, NO2, and other pollutants twice daily on a North-American domain with 10-km horizontal grid spacing and 80 vertical levels. A closely related AQ forecast system with near-real-time wildfire emissions, known as FireWork, has been run by CMCO during the Canadian wildfire season (April to October) since 2014. This system became operational in June 2016. The CMCO`s operational AQ forecast systems also benefit from several support systems, such as a statistical post-processing model called UMOS-AQ that is applied to enhance forecast reliability at point locations with AQ monitors. The Regional Deterministic Air Quality Analysis (RDAQA) system has also been connected to the RAQDPS since February 2013, and hourly surface objective analyses are now available for O3, PM2.5, NO2, PM10, SO2 and, indirectly, the Canadian Air Quality Health Index. As of June 2015, another version of the RDAQA has been connected to FireWork (RDAQA-FW). For verification purposes, CMCO developed a third support system called Verification for Air QUality Models (VAQUM), which has a geospatial relational database core and which enables continuous monitoring of the AQ forecast systems' performance. Urban environments are particularly subject to AQ pollution. In order to improve the services offered, ECCC has recently been investing efforts to develop a high resolution air quality prediction capability for urban areas in Canada. In this presentation, a comprehensive description of the ECCC AQ systems will be provided, along with a discussion on AQ systems performance. Recent improvements, current challenges, and future directions of the Canadian operational AQ program will also be discussed.

  19. TIME-RELEVANT BEACH AND RECREATIONAL WATER QUALITY AND MONITORING AND REPORTING

    EPA Science Inventory

    This handbook provides information on how to design and implement a time-relevant water quality monitoring program for beaches and other recreational waters. It was developed to help interested communities learn more about the beach monitoring projects associated with EPA's Envir...

  20. Amoeba-related health risk in drinking water systems: could monitoring of amoebae be a complementary approach to current quality control strategies?

    PubMed

    Codony, Francesc; Pérez, Leonardo Martín; Adrados, Bárbara; Agustí, Gemma; Fittipaldi, Mariana; Morató, Jordi

    2012-01-01

    Culture-based methods for fecal indicator microorganisms are the standard protocol to assess potential health risk from drinking water systems. However, these traditional fecal indicators are inappropriate surrogates for disinfection-resistant fecal pathogens and the indigenous pathogens that grow in drinking water systems. There is now a range of molecular-based methods, such as quantitative PCR, which allow detection of a variety of pathogens and alternative indicators. Hence, in addition to targeting total Escherichia coli (i.e., dead and alive) for the detection of fecal pollution, various amoebae may be suitable to indicate the potential presence of pathogenic amoeba-resisting microorganisms, such as Legionellae. Therefore, monitoring amoeba levels by quantitative PCR could be a useful tool for directly and indirectly evaluating health risk and could also be a complementary approach to current microbial quality control strategies for drinking water systems.

  1. Quality assurance for online adapted treatment plans: Benchmarking and delivery monitoring simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Taoran, E-mail: taoran.li.duke@gmail.com; Wu, Qiuwen; Yang, Yun

    Purpose: An important challenge facing online adaptive radiation therapy is the development of feasible and efficient quality assurance (QA). This project aimed to validate the deliverability of online adapted plans and develop a proof-of-concept online delivery monitoring system for online adaptive radiation therapy QA. Methods: The first part of this project benchmarked automatically online adapted prostate treatment plans using traditional portal dosimetry IMRT QA. The portal dosimetry QA results of online adapted plans were compared to original (unadapted) plans as well as randomly selected prostate IMRT plans from our clinic. In the second part, an online delivery monitoring system wasmore » designed and validated via a simulated treatment with intentional multileaf collimator (MLC) errors. This system was based on inputs from the dynamic machine information (DMI), which continuously reports actual MLC positions and machine monitor units (MUs) at intervals of 50 ms or less during delivery. Based on the DMI, the system performed two levels of monitoring/verification during the delivery: (1) dynamic monitoring of cumulative fluence errors resulting from leaf position deviations and visualization using fluence error maps (FEMs); and (2) verification of MLC positions against the treatment plan for potential errors in MLC motion and data transfer at each control point. Validation of the online delivery monitoring system was performed by introducing intentional systematic MLC errors (ranging from 0.5 to 2 mm) to the DMI files for both leaf banks. These DMI files were analyzed by the proposed system to evaluate the system’s performance in quantifying errors and revealing the source of errors, as well as to understand patterns in the FEMs. In addition, FEMs from 210 actual prostate IMRT beams were analyzed using the proposed system to further validate its ability to catch and identify errors, as well as establish error magnitude baselines for prostate IMRT

  2. REAL-TIME REMOTE MONITORING OF DRINKING WATER QUALITY

    EPA Science Inventory

    Over the past eight years, the U.S. Environmental Protection Agency's (EPA) Office of Research and Development (ORD) has funded the testing and evaluation of various online "real-time" technologies for monitoring drinking water quality. The events of 9/11 and subsequent threats t...

  3. Design, Certification, and Deployment of the Colorimetric Water Quality Monitoring Kit (CWQMK)

    NASA Technical Reports Server (NTRS)

    Gazda, Daniel B.; Nolan, Daniel J.; Rutz, Jeff A.; Schultz, John R.; Siperko, Lorraine M.; Porter, Marc D.; Lipert, Robert J.; Flint, Stephanie M.; McCoy, J. Torin

    2010-01-01

    In August 2009, an experimental water quality monitoring kit based on Colorimetric Solid Phase Extraction (CSPE) technology was delivered to the International Space Station (ISS) aboard STS-128/17A. The kit, called the Colorimetric Water Quality Monitoring Kit (CWQMK), was flown and deployed as a Station Development Test Objective (SDTO) experiment on the ISS. The goal of the SDTO experiment is to evaluate the acceptability of CSPE technology for routine water quality monitoring on the ISS. This paper provides an overview of the SDTO experiment, as well as a detailed description of the CWQMK hardware and a summary of the testing and analysis conducted to certify the CWQMK for use on the ISS. The initial results obtained from the SDTO experiment are also reported and discussed in detail

  4. Non-invasive system for monitoring of the manufacturing equipment

    NASA Astrophysics Data System (ADS)

    Mazăre, A. G.; Belu, N.; Ionescu, L. M.; Rachieru, N.; Misztal, A.

    2017-08-01

    The automotive industry is one of the most important industries in the world that concerns the economy and the world culture. High demand has resulted in increasing of the pressure on the production lines. In conclusion, it is required more careful in monitoring of the production equipment not only for maintenance but also for staff safety and to increase the quality of production. In this paper, we propose a solution for non-invasive monitoring of the industrial equipment operation by measuring the current consumption on energy supply lines. Thus, it is determined the utilization schedule of the equipment and operation mode. Based on these measurements, it’s built an activity report for that equipment, available to the quality management and maintenance team. The solution consists of the current measuring equipment, with self-harvesting capabilities and radio transceiver, and an embedded system which run a server. The current measuring equipment will transmit data about consumption of each energy supply network line where is placed the industrial equipment. So, we have an internal measuring radio network. The embedded system will collect data for the equipment and put in a local data base and it will provide via an intranet application. The entire system not requires any supplementary energy supply and interventions in the factory infrastructure. It is experimented in a company from the automotive industries.

  5. Development of a generic system for real-time data access and remote control of multiple in-situ water quality monitoring instruments

    NASA Astrophysics Data System (ADS)

    Wright, S. A.; Bennett, G. E.; Andrews, T.; Melis, T. S.; Topping, D. J.

    2005-05-01

    Currently, in-situ monitoring of water quality parameters (e.g. water temperature, conductivity, turbidity) in the Colorado River ecosystem typically consists of deploying instruments in the river, retrieving them at a later date, downloading the datalogger, then examining the data; an arduous process in the remote settings of Grand Canyon. Under this protocol, data is not available real-time and there is no way to detect problems with the instrumentation until after retrieval. The next obvious stage in the development of in-situ monitoring in Grand Canyon was the advent of one-way telemetry, i.e. streaming data in real-time from the instrument to the office and/or the world-wide-web. This protocol allows for real-time access to data and the identification of instrumentation problems, but still requires a site visit to address instrument malfunctions, i.e. the user does not have the ability to remotely control the instrument. At some field sites, such as the Colorado River in Grand Canyon, site visitation is restricted by remoteness and lack of traditional access routes (i.e. roads). Even at less remote sites, it may still be desirable to have two-way communication with instruments in order to, for example, diagnose and potentially fix instrumentation problems, change sampling parameters to save battery power, etc., without having to visit the site. To this end, the U.S. Geological Survey, Grand Canyon Monitoring and Research Center, is currently developing and testing a high-speed, two-way communication system that allows for real-time data access and remote control of instrumentation. The approach tested relies on internet access and may be especially useful in areas where land-line or cellular connections are unavailable. The system is composed of off-the-shelf products, uses a commercial broadband satellite service, and is designed in a generic way such that any instrument that communicates through RS-232 communication (i.e. a serial port) is compatible with

  6. Monitoring water quality in a hypereutrophic reservoir using Landsat ETM+ and OLI sensors: how transferable are the water quality algorithms?

    PubMed

    Deutsch, Eliza S; Alameddine, Ibrahim; El-Fadel, Mutasem

    2018-02-15

    The launch of the Landsat 8 in February 2013 extended the life of the Landsat program to over 40 years, increasing the value of using Landsat to monitor long-term changes in the water quality of small lakes and reservoirs, particularly in poorly monitored freshwater systems. Landsat-based water quality hindcasting often incorporate several Landsat sensors in an effort to increase the temporal range of observations; yet the transferability of water quality algorithms across sensors remains poorly examined. In this study, several empirical algorithms were developed to quantify chlorophyll-a, total suspended matter (TSM), and Secchi disk depth (SDD) from surface reflectance measured by Landsat 7 ETM+ and Landsat 8 OLI sensors. Sensor-specific multiple linear regression models were developed by correlating in situ water quality measurements collected from a semi-arid eutrophic reservoir with band ratios from Landsat ETM+ and OLI sensors, along with ancillary data (water temperature and seasonality) representing ecological patterns in algae growth. Overall, ETM+-based models outperformed (adjusted R 2 chlorophyll-a = 0.70, TSM = 0.81, SDD = 0.81) their OLI counterparts (adjusted R 2 chlorophyll-a = 0.50, TSM = 0.58, SDD = 0.63). Inter-sensor differences were most apparent for algorithms utilizing the Blue spectral band. The inclusion of water temperature and seasonality improved the power of TSM and SDD models.

  7. The Copernicus Atmosphere Monitoring Service: facilitating the prediction of air quality from global to local scales

    NASA Astrophysics Data System (ADS)

    Engelen, R. J.; Peuch, V. H.

    2017-12-01

    The European Copernicus Atmosphere Monitoring Service (CAMS) operationally provides daily forecasts of global atmospheric composition and regional air quality. The global forecasting system is using ECMWF's Integrated Forecasting System (IFS), which is used for numerical weather prediction and which has been extended with modules for atmospheric chemistry, aerosols and greenhouse gases. The regional forecasts are produced by an ensemble of seven operational European air quality models that take their boundary conditions from the global system and provide an ensemble median with ensemble spread as their main output. Both the global and regional forecasting systems are feeding their output into air quality models on a variety of scales in various parts of the world. We will introduce the CAMS service chain and provide illustrations of its use in downstream applications. Both the usage of the daily forecasts and the usage of global and regional reanalyses will be addressed.

  8. Engineering monitoring expert system's developer

    NASA Technical Reports Server (NTRS)

    Lo, Ching F.

    1991-01-01

    This research project is designed to apply artificial intelligence technology including expert systems, dynamic interface of neural networks, and hypertext to construct an expert system developer. The developer environment is specifically suited to building expert systems which monitor the performance of ground support equipment for propulsion systems and testing facilities. The expert system developer, through the use of a graphics interface and a rule network, will be transparent to the user during rule constructing and data scanning of the knowledge base. The project will result in a software system that allows its user to build specific monitoring type expert systems which monitor various equipments used for propulsion systems or ground testing facilities and accrues system performance information in a dynamic knowledge base.

  9. Vital signs monitoring system

    NASA Technical Reports Server (NTRS)

    Steffen, Dale A. (Inventor); Sturm, Ronald E. (Inventor); Rinard, George A. (Inventor)

    1981-01-01

    A system is disclosed for monitoring vital physiological signs. Each of the system components utilizes a single hybrid circuit with each component having high accuracy without the necessity of repeated calibration. The system also has low power requirements, provides a digital display, and is of sufficiently small size to be incorporated into a hand-carried case for portable use. Components of the system may also provide independent outputs making the component useful, of itself, for monitoring one or more vital signs. The overall system preferably includes an ECG amplifier and cardiotachometer signal conditioner unit, an impedance pneumograph and respiration rate signal conditioner unit, a heart/breath rate processor unit, a temperature monitoring unit, a selector switch, a clock unit, and an LCD driver unit and associated LCDs, with the system being capable of being expanded as needed or desired, such as, for example, by addition of a systolic/diastolic blood pressure unit.

  10. False alarm reduction in BSN-based cardiac monitoring using signal quality and activity type information.

    PubMed

    Tanantong, Tanatorn; Nantajeewarawat, Ekawit; Thiemjarus, Surapa

    2015-02-09

    False alarms in cardiac monitoring affect the quality of medical care, impacting on both patients and healthcare providers. In continuous cardiac monitoring using wireless Body Sensor Networks (BSNs), the quality of ECG signals can be deteriorated owing to several factors, e.g., noises, low battery power, and network transmission problems, often resulting in high false alarm rates. In addition, body movements occurring from activities of daily living (ADLs) can also create false alarms. This paper presents a two-phase framework for false arrhythmia alarm reduction in continuous cardiac monitoring, using signals from an ECG sensor and a 3D accelerometer. In the first phase, classification models constructed using machine learning algorithms are used for labeling input signals. ECG signals are labeled with heartbeat types and signal quality levels, while 3D acceleration signals are labeled with ADL types. In the second phase, a rule-based expert system is used for combining classification results in order to determine whether arrhythmia alarms should be accepted or suppressed. The proposed framework was validated on datasets acquired using BSNs and the MIT-BIH arrhythmia database. For the BSN dataset, acceleration and ECG signals were collected from 10 young and 10 elderly subjects while they were performing ADLs. The framework reduced the false alarm rate from 9.58% to 1.43% in our experimental study, showing that it can potentially assist physicians in diagnosing a vast amount of data acquired from wireless sensors and enhance the performance of continuous cardiac monitoring.

  11. Statistical approaches used to assess and redesign surface water-quality-monitoring networks.

    PubMed

    Khalil, B; Ouarda, T B M J

    2009-11-01

    An up-to-date review of the statistical approaches utilized for the assessment and redesign of surface water quality monitoring (WQM) networks is presented. The main technical aspects of network design are covered in four sections, addressing monitoring objectives, water quality variables, sampling frequency and spatial distribution of sampling locations. This paper discusses various monitoring objectives and related procedures used for the assessment and redesign of long-term surface WQM networks. The appropriateness of each approach for the design, contraction or expansion of monitoring networks is also discussed. For each statistical approach, its advantages and disadvantages are examined from a network design perspective. Possible methods to overcome disadvantages and deficiencies in the statistical approaches that are currently in use are recommended.

  12. Volunteer Macroinvertebrate Monitoring: Tensions Among Group Goals, Data Quality, and Outcomes

    NASA Astrophysics Data System (ADS)

    Nerbonne, Julia Frost; Nelson, Kristen C.

    2008-09-01

    Volunteer monitoring of natural resources is promoted for its ability to increase public awareness, to provide valuable knowledge, and to encourage policy change that promotes ecosystem health. We used the case of volunteer macroinvertebrate monitoring (VMM) in streams to investigate whether the quality of data collected is correlated with data use and organizers’ perception of whether they have achieved these outcomes. We examined the relation between site and group characteristics, data quality, data use, and perceived outcomes (education, social capital, and policy change). We found that group size and the degree to which citizen groups perform tasks on their own (rather than aided by professionals) positively correlated with the quality of data collected. Group size and number of years monitoring positively influenced whether a group used their data. While one might expect that groups committed to collecting good-quality data would be more likely to use it, there was no relation between data quality and data use, and no relation between data quality and perceived outcomes. More data use was, however, correlated with a group’s feeling of connection to a network of engaged citizens and professionals. While VMM may hold promise for bringing citizens and scientists together to work on joint conservation agendas, our data illustrate that data quality does not correlate with a volunteer group’s desire to use their data to promote regulatory change. Therefore, we encourage scientists and citizens alike to recognize this potential disconnect and strive to be explicit about the role of data in conservation efforts.

  13. Automatic, nondestructive test monitors in-process weld quality

    NASA Technical Reports Server (NTRS)

    Deal, F. C.

    1968-01-01

    Instrument automatically and nondestructively monitors the quality of welds produced in microresistance welding. It measures the infrared energy generated in the weld as the weld is made and compares this energy with maximum and minimum limits of infrared energy values previously correlated with acceptable weld-strength tolerances.

  14. Towards a rational strategy for monitoring of microbiological quality of ambient waters

    PubMed Central

    Poma, Hugo Ramiro; Cacciabue, Dolores Gutiérrez; Garcé, Beatriz; Gonzo, Elio Emilio; Rajal, Verónica Beatriz

    2012-01-01

    Water is one of the main sources of human exposure to microbiological hazards. Although legislation establishes regulatory standards in terms of fecal indicator bacteria to assess the microbiological quality of water, these do not necessarily predict the presence of pathogens such as parasites and viruses. Better surveillance and management strategies are needed to assess the risk of pathogens waterborne transmission. We established a baseline dataset to characterize river water quality, identify changes over time, and design a rational monitoring strategy. Data from a year-long monthly monitoring campaign of the polluted Arenales River (Argentina), were analyzed to statistically correlate physicochemical and microbiological variables, the seasonal and longitudinal variation of the water quality and determine the similarity between study sites. The measured variables (sixteen) reflected the deterioration in the river quality through the city. Different viruses and parasites found did not correlate with the concentration of total and thermotolerant coliforms. There was significant seasonal variation for temperature, turbidity, conductivity, dissolved oxygen, enterococci, and norovirus. Strong correlations between some variables were found; we selected eight variables (dissolved oxygen, conductivity, turbidity, total and thermotolerant coliforms, Enterococcus, and adenovirus and Microsporidium as viral and parasitological indicators, respectively) for future monitoring. There was similarity between the monitoring locations, which were grouped into four clusters validated by cophenetic correlation and supported by discriminant analysis. This allowed us to reduce the number of sites, from eleven down to five. Sixty seven percent of the total variance and the correlation structure between variables was explained using five principal components. All these analyses led to a new long-term systematic monitoring scheme A rational monitoring strategy based on the selection of

  15. Potential of integrated continuous surveys and quality management to support monitoring, evaluation, and the scale-up of health interventions in developing countries.

    PubMed

    Rowe, Alexander K

    2009-06-01

    Well-funded initiatives are challenging developing countries to increase health intervention coverage and show impact. Despite substantial resources, however, major obstacles include weak health systems, a lack of reasonably accurate monitoring data, and inadequate use of data for managing programs. This report discusses how integrated continuous surveys and quality management (I-Q), which are well-recognized approaches in wealthy countries, could support intervention scale-up, monitoring and evaluation, quality control for commodities, capacity building, and implementation research in low-resource settings. Integrated continuous surveys are similar to existing national cross-sectional surveys of households and health facilities, except data are collected over several years by permanent teams, and most results are reported monthly at the national, province, and district levels. Quality management involves conceptualizing work as processes, involving all workers in quality improvement, monitoring quality, and teams that improve quality with "plan-do-study-act" cycles. Implementing and evaluating I-Q in a low-income country would provide critical information on the value of this approach.

  16. Automatised data quality monitoring of the LHCb Vertex Locator

    NASA Astrophysics Data System (ADS)

    Bel, L.; Crocombe, A. Ch.; Gersabeck, M.; Pearce, A.; Majewski, M.; Szumlak, T.

    2017-10-01

    The LHCb Vertex Locator (VELO) is a silicon strip semiconductor detector operating at just 8mm distance to the LHC beams. Its 172,000 strips are read at a frequency of 1.1 MHz and processed by off-detector FPGAs followed by a PC cluster that reduces the event rate to about 10 kHz. During the second run of the LHC, which lasts from 2015 until 2018, the detector performance will undergo continued change due to radiation damage effects. This necessitates a detailed monitoring of the data quality to avoid adverse effects on the physics analysis performance. The VELO monitoring infrastructure has been re-designed compared to the first run of the LHC when it was based on manual checks. The new system is based around an automatic analysis framework, which monitors the performance of new data as well as long-term trends and using dedicated algorithms flags issues whenever they arise. The new analysis framework then analyses the plots that are produced by these algorithms. One of its tasks is to perform custom comparisons between the newly processed data and that from reference runs. The most-likely scenario in which this analysis would identify an issue is the parameters of the readout electronics no longer being optimal and requiring retuning. The data of the monitoring plots can be reduced further, e.g. by evaluating averages, and these quantities are input to long-term trending. This is used to detect slow variation of quantities, which are not detectable by the comparison of two nearby runs. Such gradual change is what is expected due to radiation damage effects. It is essential to detect these changes early such that measures can be taken, e.g. adjustments of the operating voltage, to prevent any impact on the quality of high-level quantities and thus on physics analyses. The plots as well as the analysis results and trends are made available through graphical user interfaces (GUIs). These GUIs are dynamically configured by a single configuration that determines the

  17. LOCATING MONITORING STATIONS IN WATER DISTRIBUTION SYSTEMS

    EPA Science Inventory

    Water undergoes changes in quality between the time it leaves the treatment plant and the time it reaches the customer's tap, making it important to select monitoring stations that will adequately monitor these changers. But because there is no uniform schedule or framework for ...

  18. Operational monitoring and forecasting of bathing water quality through exploiting satellite Earth observation and models: The AlgaRisk demonstration service

    NASA Astrophysics Data System (ADS)

    Shutler, J. D.; Warren, M. A.; Miller, P. I.; Barciela, R.; Mahdon, R.; Land, P. E.; Edwards, K.; Wither, A.; Jonas, P.; Murdoch, N.; Roast, S. D.; Clements, O.; Kurekin, A.

    2015-04-01

    Coastal zones and shelf-seas are important for tourism, commercial fishing and aquaculture. As a result the importance of good water quality within these regions to support life is recognised worldwide and a number of international directives for monitoring them now exist. This paper describes the AlgaRisk water quality monitoring demonstration service that was developed and operated for the UK Environment Agency in response to the microbiological monitoring needs within the revised European Union Bathing Waters Directive. The AlgaRisk approach used satellite Earth observation to provide a near-real time monitoring of microbiological water quality and a series of nested operational models (atmospheric and hydrodynamic-ecosystem) provided a forecast capability. For the period of the demonstration service (2008-2013) all monitoring and forecast datasets were processed in near-real time on a daily basis and disseminated through a dedicated web portal, with extracted data automatically emailed to agency staff. Near-real time data processing was achieved using a series of supercomputers and an Open Grid approach. The novel web portal and java-based viewer enabled users to visualise and interrogate current and historical data. The system description, the algorithms employed and example results focussing on a case study of an incidence of the harmful algal bloom Karenia mikimotoi are presented. Recommendations and the potential exploitation of web services for future water quality monitoring services are discussed.

  19. Design of wireless communication system for environmental monitoring

    NASA Astrophysics Data System (ADS)

    Jiang, Li; Zhang, Xiaoyang; Sun, Zhixiang; Tian, Youcheng; Wang, Juan; Guo, Jianghua

    2017-05-01

    This paper introduces the basic principle and advantages of GPRS data transmission, and discusses in detail about the hardware structure of the GPRS module, the connection mode and the research process of GPRS application in the device. The feasibility and superiority of GPRS data transmission in wireless water quality monitoring device have been tested and proved, which provides great convenience for water quality monitoring, and has good application prospect.

  20. Exploring the potential of the permanganate oxidation method as a tool to monitor soil quality in agricultural upland systems of Southeast Asia

    NASA Astrophysics Data System (ADS)

    Hepp, Catherine M.; Bruun, Thilde Bech; de Neergaard, Andreas

    2014-05-01

    The transition to more intensified upland systems is having an impact on the soil quality, defined as the ability of a soil to both provide and maintain essential services to an ecosystem. As many tropical upland soils are inherently low in quality, it is essential that impacts be monitored. Soil quality is assessed by using a combination of parameters that serve as indicators and cover the soil chemical, biological and physical properties. An ideal indicator should be sensitive to changes in the environment and management practices and should be widely accessible, meaning low resource requirement (i.e. time and equipment). Total organic carbon (TOC) content is a commonly used indicator of soil quality as it is linked to many soil functions and processes; however analysis is costly and requires access to advanced instrumental facilities, rendering it unsuited for many developing countries. An alternative indicator is the soil fraction dominated by easily decomposable carbon; this may be measured by treating soil samples with 0.2M potassium permanganate (KMnO4), an oxidizing agent which is thought to mimic the enzymes released by the soil microbial community. The advantage of this method is that it is accessible: it is fast, requires little resource input and is field appropriate. There is no consensus however as to which soil carbon fraction the method targets. Furthermore Skjemstad et al. (2006) has indicated that KMnO4 may oxidise charcoal, a component of the non-labile carbon pool; this has implications for the suitability of the method when used for soils of shifting cultivation systems. The purpose of this study was to investigate the potential of permanganate oxidizable carbon (Pox C) as a reliable indicator of soil quality in agricultural upland systems in Northern Lao PDR. Focus was placed on the relations between Pox C and other soil quality parameters (bulk density, pH, CEC, TOC, total N, exchangeable K, plant available P) and upland rice yields. The

  1. Wireless Laser Range Finder System for Vertical Displacement Monitoring of Mega-Trusses during Construction

    PubMed Central

    Park, Hyo Seon; Son, Sewook; Choi, Se Woon; Kim, Yousok

    2013-01-01

    As buildings become increasingly complex, construction monitoring using various sensors is urgently needed for both more systematic and accurate safety management and high-quality productivity in construction. In this study, a monitoring system that is composed of a laser displacement sensor (LDS) and a wireless sensor node was proposed and applied to an irregular building under construction. The subject building consists of large cross-sectional members, such as mega-columns, mega-trusses, and edge truss, which secured the large spaces. The mega-trusses and edge truss that support this large space are of the cantilever type. The vertical displacement occurring at the free end of these members was directly measured using an LDS. To validate the accuracy and reliability of the deflection data measured from the LDS, a total station was also employed as a sensor for comparison with the LDS. In addition, the numerical simulation result was compared with the deflection obtained from the LDS and total station. Based on these investigations, the proposed wireless displacement monitoring system was able to improve the construction quality by monitoring the real-time behavior of the structure, and the applicability of the proposed system to buildings under construction for the evaluation of structural safety was confirmed. PMID:23648650

  2. Water Quality & Pollutant Source Monitoring: Field and Laboratory Procedures. Training Manual.

    ERIC Educational Resources Information Center

    Office of Water Program Operations (EPA), Cincinnati, OH. National Training and Operational Technology Center.

    This training manual presents material on techniques and instrumentation used to develop data in field monitoring programs and related laboratory operations concerned with water quality and pollution monitoring. Topics include: collection and handling of samples; bacteriological, biological, and chemical field and laboratory methods; field…

  3. Warehouse multipoint temperature and humidity monitoring system design based on Kingview

    NASA Astrophysics Data System (ADS)

    Ou, Yanghui; Wang, Xifu; Liu, Jingyun

    2017-04-01

    Storage is the key link of modern logistics. Warehouse environment monitoring is an important part of storage safety management. To meet the storage requirements of different materials, guarantee their quality in the greatest extent, which has great significance. In the warehouse environment monitoring, the most important parameters are air temperature and relative humidity. In this paper, a design of warehouse multipoint temperature and humidity monitoring system based on King view, which realizes the multipoint temperature and humidity data real-time acquisition, monitoring and storage in warehouse by using temperature and humidity sensor. Also, this paper will take the bulk grain warehouse as an example and based on the data collected in real-time monitoring, giving the corresponding expert advice that combined with the corresponding algorithm, providing theoretical guidance to control the temperature and humidity in grain warehouse.

  4. The relative merits of monitoring and domestic wells for ground water quality investigations

    USGS Publications Warehouse

    Jones, J.L.; Roberts, L.M.

    1999-01-01

    The results of two studies of the effect of agricultural land use on shallow ground water quality indicate that monitoring wells may be a better choice than domestic wells for studies of pesticide occurrence or transport, or for use as early-warning indicators of potential drinking water contamination. Because domestic wells represent the used resource, and because domestic well water may be affected by historical rather than current pesticide and land- use practices, domestic wells would be the best choice for an investigation of drinking water quality. The key difference between the domestic and monitoring wells appears to be that the monitoring wells in this study were installed exclusively to sample the shallowest possible ground water. For these studies, 48 shallow domestic wells and 41 monitoring wells were located randomly within two land-use settings (row crops and orchards) in an irrigated agricultural region of eastern Washington and sampled for 145 pesticides (including nine pesticide degradates) and common water quality indicators. Constructing and sampling monitoring wells required approximately four times the resources (including manpower and materials) as locating and sampling domestic wells. Sample collection and quality assurance procedures and analytical techniques were identical except that a portable submersible pump was required for monitoring wells. In both land-use settings, no significant difference in nitrate concentration was found between well types; however, the average number of pesticides detected per well was significantly higher (p<0.05) in the monitoring wells. A greater variety of pesticides was detected in monitoring wells; many were detected only in monitoring wells. More than 60% of detections of pesticides that were found only in domestic wells were of compounds that are no longer in use. These differences in ground water quality found in this study relate to the depth of the well and are apparently related to the age of ground

  5. Is the soil quality monitoring an effective tool in consumers' protection of agricultural crops from cadmium soil contamination?-a case of the Silesia region (Poland).

    PubMed

    Piekut, Agata; Baranowska, Renata; Marchwińska-Wyrwał, Ewa; Ćwieląg-Drabek, Małgorzata; Hajok, Ilona; Dziubanek, Grzegorz; Grochowska-Niedworok, Elżbieta

    2017-12-16

    The monitoring of soil quality should be a control tool used to reduce the adverse health effects arising from exposure to toxic chemicals in soil through cultivated crop absorption. The aim of the study was to evaluate the effectiveness of the monitoring and control system of soil quality in Poland, in terms of consumer safety, for agricultural plants cultivated in areas with known serious cadmium contamination, such as Silesia Province. To achieve the objective, the contents of cadmium in soils and vegetables in the Silesia administrative area were examined. The obtained results were compared with the results of soil contamination from the quality monitoring of arable soil in Poland. The studies show a significant exceedance of the permissible values of cadmium in soil samples and the vegetables cultivated on that soil. The threat to consumer health is a valid concern, although this threat was not indicated by the results of the national monitoring of soil quality. The results indicated an unequal distribution of risk to consumers resulting from contaminated soil. Moreover, the monitoring systems should be designed at the local or regional scale to guarantee the safety of consumers of edible plants cultivated in the areas contaminated with cadmium.

  6. Carbon nanotube sensors integrated inside a microfluidic channel for water quality monitoring

    NASA Astrophysics Data System (ADS)

    Liu, Yu; Li, Xinghui; Dokmeci, Mehmet R.; Wang, Ming L.

    2011-04-01

    Single-walled carbon nanotubes (SWNTs) with their unique electrical properties and large surface area are remarkable materials for detecting low concentration of toxic and hazardous chemicals (both from the gaseous and liquid phases). Ionic adsorbates in water will attach on to SWNTs and drastically alter their electrical properties. Several SWNTs based pH and chemical sensors have been demonstrated. However, most of them require external components to test and analyze the response of SWNTs to ions inside the liquid samples. Here, we report a water quality monitoring sensor composed of SWNTs integrated inside microfluidic channels and on-chip testing components with a wireless transmission board. To detect multiple analytes in water requires the functionalization of SWNTs with different chemistries. In addition, microfluidic channels are used to guide liquid samples to individual nanotube sensors in an efficient manner. Furthermore, the microfluidic system enables sample mixing and separation before testing. To realize the nanosensors, first microelectrodes were fabricated on an oxidized silicon substrate. Next, PDMS micro channels were fabricated and bonded on the substrate. These channels can be incorporated with a microfluidic system which can be designed to manipulate different analytes for specific molecule detection. Low temperature, solution based Dielectrophoretic (DEP) assembly was conducted inside this microfluidic system which successfully bridged SWNTs between the microelectrodes. The SWNTs sensors were next characterized with different pH buffer solutions. The resistance of SWNTs had a linearly increase as the pH values ranged from 5 to 8. The nanosensor incorporated within the microfluidic system is a versatile platform and can be utilized to detect numerous water pollutants, including toxic organics and microorganisms down to low concentrations. On-chip processing and wireless transmission enables the realization of a full autonomous system for real

  7. Gage monitors quality of cross-wire resistance welds

    NASA Technical Reports Server (NTRS)

    Etzel, J.; Piltch, A.

    1968-01-01

    Gage nondestructively monitors the quality of cross-wire resistance welds during the welding operation. The gage gives a dial indication of the relative embedment of the cross wires during the actual welding operation. A direct relationship exists between the depth of embedment and both weld strength and consistency.

  8. Understanding Local Ecology: Syllabus for Monitoring Water Quality.

    ERIC Educational Resources Information Center

    Iowa Univ., Iowa City.

    This syllabus gives detailed information on monitoring water quality for teachers and students. It tells how to select a sample site; how to measure physical characteristics such as temperature, turbidity, and stream velocity; how to measure chemical parameters such as alkalinity, dissolved oxygen levels, phosphate levels, and ammonia nitrogen…

  9. Highly survivable bed pressure mat remote patient monitoring system for mHealth.

    PubMed

    Joshi, Vilas; Holtzman, Megan; Arcelus, Amaya; Goubran, Rafik; Knoefel, Frank

    2012-01-01

    The high speed mobile networks like 4G and beyond are making a ubiquitous remote patient monitoring (RPM) system using multiple sensors and wireless sensor networks a realistic possibility. The high speed wireless RPM system will be an integral part of the mobile health (mHealth) paradigm reducing cost and providing better service to the patients. While the high speed wireless RPM system will allow clinicians to monitor various chronic and acute medical conditions, the reliability of such system will depend on the network Quality of Service (QoS). The RPM system needs to be resilient to temporary reduced network QoS. This paper presents a highly survivable bed pressure mat RPM system design using an adaptive information content management methodology for the monitored sensor data. The proposed design improves the resiliency of the RPM system under adverse network conditions like congestion and/or temporary loss of connectivity. It also shows how the proposed RPM system can reduce the information rate and correspondingly reduce the data transfer rate by a factor of 5.5 and 144 to address temporary network congestion. The RPM system data rate reduction results in a lower specificity and sensitivity for the features being monitored but increases the survivability of the system from 1 second to 2.4 minutes making it highly robust.

  10. Twelve Months of Air Quality Monitoring at Ash Meadows National Wildlife Refuge, Southwestern Rural Nevada, U.S.A (EMSI April 2007)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Engelbrecht, Johann P; Shafer, David S; Campbell, Dave

    The one year of air quality monitoring data collected at the Ash Meadows National Wildlife Refuge (NWR) was the final part of the air quality "Scoping Studies" for the Environmental Monitoring Systems Initiative (EMSI) in southern and central Nevada. The objective of monitoring at Ash Meadows was to examine aerosol and meteorological data, seasonal trends in aerosol and meteorological parameters as well as to examine evidence for long distance transport of some constituents. The 9,307 hectare refuge supports more than 50 springs and 24 endemic species, including the only population of the federally listed endangered Devil’s Hole pupfish (Cyprinodon diabolis)more » (U.S. Fish and Wildlife Service, 1990). Ash Meadows NWR is located in a Class II air quality area, and the aerosol measurements collected with this study are compared to those of Interagency Monitoring of Protected Visual Environments (IMPROVE) sites. Measurements taken at Ash Meadows NWR over a period of 12 months provide new baseline air quality and meteorological information for rural southwestern Nevada, specifically Nye County and the Amargosa Valley.« less

  11. Physical soil quality indicators for monitoring British soils

    NASA Astrophysics Data System (ADS)

    Corstanje, Ron; Mercer, Theresa G.; Rickson, Jane R.; Deeks, Lynda K.; Newell-Price, Paul; Holman, Ian; Kechavarsi, Cedric; Waine, Toby W.

    2017-09-01

    Soil condition or quality determines its ability to deliver a range of functions that support ecosystem services, human health and wellbeing. The increasing policy imperative to implement successful soil monitoring programmes has resulted in the demand for reliable soil quality indicators (SQIs) for physical, biological and chemical soil properties. The selection of these indicators needs to ensure that they are sensitive and responsive to pressure and change, e.g. they change across space and time in relation to natural perturbations and land management practices. Using a logical sieve approach based on key policy-related soil functions, this research assessed whether physical soil properties can be used to indicate the quality of British soils in terms of their capacity to deliver ecosystem goods and services. The resultant prioritised list of physical SQIs was tested for robustness, spatial and temporal variability, and expected rate of change using statistical analysis and modelling. Seven SQIs were prioritised: soil packing density, soil water retention characteristics, aggregate stability, rate of soil erosion, depth of soil, soil structure (assessed by visual soil evaluation) and soil sealing. These all have direct relevance to current and likely future soil and environmental policy and are appropriate for implementation in soil monitoring programmes.

  12. 30 CFR 27.21 - Methane-monitoring system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Methane-monitoring system. 27.21 Section 27.21... APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS Construction and Design Requirements § 27.21 Methane-monitoring system. (a) A methane-monitoring system shall be so designed that any machine or equipment, which...

  13. 30 CFR 27.21 - Methane-monitoring system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Methane-monitoring system. 27.21 Section 27.21... APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS Construction and Design Requirements § 27.21 Methane-monitoring system. (a) A methane-monitoring system shall be so designed that any machine or equipment, which...

  14. 30 CFR 27.21 - Methane-monitoring system.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Methane-monitoring system. 27.21 Section 27.21... APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS Construction and Design Requirements § 27.21 Methane-monitoring system. (a) A methane-monitoring system shall be so designed that any machine or equipment, which...

  15. 30 CFR 27.21 - Methane-monitoring system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Methane-monitoring system. 27.21 Section 27.21... APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS Construction and Design Requirements § 27.21 Methane-monitoring system. (a) A methane-monitoring system shall be so designed that any machine or equipment, which...

  16. 30 CFR 27.21 - Methane-monitoring system.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Methane-monitoring system. 27.21 Section 27.21... APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS Construction and Design Requirements § 27.21 Methane-monitoring system. (a) A methane-monitoring system shall be so designed that any machine or equipment, which...

  17. Spacelab Data Processing Facility (SLDPF) quality assurance expert systems development

    NASA Technical Reports Server (NTRS)

    Kelly, Angelita C.; Basile, Lisa; Ames, Troy; Watson, Janice; Dallam, William

    1987-01-01

    Spacelab Data Processing Facility (SLDPF) expert system prototypes were developed to assist in the quality assurance of Spacelab and/or Attached Shuttle Payload (ASP) processed telemetry data. The SLDPF functions include the capturing, quality monitoring, processing, accounting, and forwarding of mission data to various user facilities. Prototypes for the two SLDPF functional elements, the Spacelab Output Processing System and the Spacelab Input Processing Element, are described. The prototypes have produced beneficial results including an increase in analyst productivity, a decrease in the burden of tedious analyses, the consistent evaluation of data, and the providing of concise historical records.

  18. Spacelab Data Processing Facility (SLDPF) quality assurance expert systems development

    NASA Technical Reports Server (NTRS)

    Kelly, Angelita C.; Basile, Lisa; Ames, Troy; Watson, Janice; Dallam, William

    1987-01-01

    Spacelab Data Processing Facility (SLDPF) expert system prototypes have been developed to assist in the quality assurance of Spacelab and/or Attached Shuttle Payload (ASP) processed telemetry data. SLDPF functions include the capturing, quality monitoring, processing, accounting, and forwarding of mission data to various user facilities. Prototypes for the two SLDPF functional elements, the Spacelab Output Processing System and the Spacelab Input Processing Element, are described. The prototypes have produced beneficial results including an increase in analyst productivity, a decrease in the burden of tedious analyses, the consistent evaluation of data, and the providing of concise historical records.

  19. Development and Application of a Next Generation Air Sensor Network for the Hong Kong Marathon 2015 Air Quality Monitoring

    PubMed Central

    Sun, Li; Wong, Ka Chun; Wei, Peng; Ye, Sheng; Huang, Hao; Yang, Fenhuan; Westerdahl, Dane; Louie, Peter K.K.; Luk, Connie W.Y.; Ning, Zhi

    2016-01-01

    This study presents the development and evaluation of a next generation air monitoring system with both laboratory and field tests. A multi-parameter algorithm was used to correct for the impact of environmental conditions on the electrochemical sensors for carbon monoxide (CO) and nitrogen dioxide (NO2) pollutants. The field evaluation in an urban roadside environment in comparison to designated monitors showed good agreement with measurement error within 5% of the pollutant concentrations. Multiple sets of the developed system were then deployed in the Hong Kong Marathon 2015 forming a sensor-based network along the marathon route. Real-time air pollution concentration data were wirelessly transmitted and the Air Quality Health Index (AQHI) for the Green Marathon was calculated, which were broadcast to the public on an hourly basis. The route-specific sensor network showed somewhat different pollutant patterns than routine air monitoring, indicating the immediate impact of traffic control during the marathon on the roadside air quality. The study is one of the first applications of a next generation sensor network in international sport events, and it demonstrated the usefulness of the emerging sensor-based air monitoring technology in rapid network deployment to supplement existing air monitoring. PMID:26861336

  20. 40 CFR 60.2170 - Is there a minimum amount of monitoring data I must obtain?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... monitoring system quality assurance or quality control activities (including, as applicable, calibration... required monitoring system quality assurance or quality control activities including, as applicable... required monitoring system quality assurance or control activities in calculations used to report emissions...

  1. Real-time Web GIS to monitor marine water quality using wave glider

    NASA Astrophysics Data System (ADS)

    Maneesa Amiruddin, Siti

    2016-06-01

    In the past decade, Malaysia has experienced unprecedented economic development and associated socioeconomic changes. As environmentalists anticipate these changes could have negative impacts on the marine and coastal environment, a comprehensive, continuous and long term marine water quality monitoring programme needs to be strengthened to reflect the government's aggressive mind-set of enhancing its authority in protection, preservation, management and enrichment of vast resources of the ocean. Wave Glider, an autonomous, unmanned marine vehicle provides continuous ocean monitoring at all times and is durable in any weather condition. Geographic Information System (GIS) technology is ideally suited as a tool for the presentation of data derived from continuous monitoring of locations, and used to support and deliver information to environmental managers and the public. Combined with GeoEvent Processor, an extension from ArcGIS for Server, it extends the Web GIS capabilities in providing real-time data from the monitoring activities. Therefore, there is a growing need of Web GIS for easy and fast dissemination, sharing, displaying and processing of spatial information which in turn helps in decision making for various natural resources based applications.

  2. Monitoring urban air quality using a high-density network of low-cost sensor nodes in Oslo, Norway.

    NASA Astrophysics Data System (ADS)

    Castell, Nuria; Schneider, Philipp; Vogt, Matthias; Dauge, Franck R.; Lahoz, William; Bartonova, Alena

    2017-04-01

    Urban air quality represents a major public health burden and is a long-standing concern to citizens. Air pollution is associated with a range of diseases, symptoms and conditions that impair health and quality of life. In Oslo, traffic, especially exhaust from heavy-duty and private diesel vehicles and dust resuspension from studded tyres, together with wood burning in winter, are the main sources of pollution. Norway, as part of the European Economic Area, is obliged to comply with the European air quality regulations and ensure clean air. Despite this, Oslo has exceeded both the NO2 and PM10 thresholds for health protection defined in the Directive 2008/50/EC. The air quality in the Oslo area is continuously monitored in 12 compliance monitoring stations. These stations provide reliable and accurate data but their density is too low to provide a detailed spatial distribution of air quality. The emergence of low-cost nodes enables observations at high spatial resolution, providing the opportunity to enhance existing monitoring systems. However, the data generated by these nodes is significantly less accurate and precise than the data provided by reference equipment. We have conducted an evaluation of low-cost nodes to monitor NO2 and PM10, comparing the data collected with low-cost nodes against CEN (European Standardization Organization) reference analysers. During January and March 2016, a network of 24 nodes was deployed in Oslo. During January, high NO2 levels were observed for several days in a row coinciding with the formation of a thermal inversion. During March, we observed an episode with high PM10 levels due to road dust resuspension. Our results show that there is a major technical challenge associated with current commercial low-cost sensors, regarding the sensor robustness and measurement repeatability. Despite this, low-cost sensor nodes are able to reproduce the NO2 and PM10 variability. The data from the sensors was employed to generate detailed

  3. Bacteriological monitoring and sustainable management of beach water quality in Malaysia: problems and prospects.

    PubMed

    Dada, Ayokunle Christopher; Asmat, Ahmad; Gires, Usup; Heng, Lee Yook; Deborah, Bandele Oluwaseun

    2012-04-28

    Despite the growing demand of tourism in Malaysia, there are no resolute efforts to develop beaches as tourist destinations. With no incentives to monitor public beaches or to use them in a sustainable manner, they might eventually degenerate in quality as a result of influx of pollutants. This calls for concerted action plans with a view to promoting their sustainable use. The success of such plans is inevitably anchored on the availability of robust quality monitoring schemes. Although significant efforts have been channelled to collation and public disclosure of bacteriological quality data of rivers, beach water monitoring appears left out. This partly explains the dearth of published information related to beach water quality data. As part of an on-going nation-wide surveillance study on the bacteriological quality of recreational beaches, this paper draws on a situation analysis with a view to proffering recommendations that could be adapted for ensuring better beach water quality in Malaysia.

  4. Bacteriological Monitoring and Sustainable Management of Beach Water Quality in Malaysia: Problems and Prospects

    PubMed Central

    Dada, Ayokunle Christopher; Asmat, Ahmad; Gires, Usup; Heng, Lee Yook; Deborah, Bandele Oluwaseun

    2012-01-01

    Despite the growing demand of tourism in Malaysia, there are no resolute efforts to develop beaches as tourist destinations. With no incentives to monitor public beaches or to use them in a sustainable manner, they might eventually degenerate in quality as a result of influx of pollutants. This calls for concerted action plans with a view to promoting their sustainable use. The success of such plans is inevitably anchored on the availability of robust quality monitoring schemes. Although significant efforts have been channelled to collation and public disclosure of bacteriological quality data of rivers, beach water monitoring appears left out. This partly explains the dearth of published information related to beach water quality data. As part of an on-going nation-wide surveillance study on the bacteriological quality of recreational beaches, this paper draws on a situation analysis with a view to proffering recommendations that could be adapted for ensuring better beach water quality in Malaysia. PMID:22980239

  5. Monitoring of the Atmosphere on the International Space Station with the Air Quality Monitor

    NASA Technical Reports Server (NTRS)

    Wallace William T.; Limero, Thomas F.; Loh, Leslie J.; Mudgett, Paul D.; Gazda, Daniel B.

    2017-01-01

    During the early years of human spaceflight, short duration missions allowed for monitoring of the spacecraft environment to be performed via archival sampling, in which samples were returned to Earth for analysis. With the construction of the International Space Station (ISS) and the accompanying extended mission durations, the need for enhanced, real-time monitors became apparent. The Volatile Organic Analyzer (VOA) operated on ISS for 7 years, where it assessed trace volatile organic compounds in the cabin air. The large and fixed-position VOA was eventually replaced with the smaller Air Quality Monitor (AQM). Since March 2013, the atmosphere of the U.S. Operating Segment (USOS) has been monitored in near real-time by a pair of AQMs. These devices consist of a gas chromatograph (GC) coupled with a differential mobility spectrometer (DMS) and currently target detection list of 22 compounds. These targets are of importance to both crew health and the Environmental Control and Life Support Systems (ECLSS) on ISS. Data is collected autonomously every 73 hours, though the units can be controlled remotely from mission control to collect data more frequently during contingency or troubleshooting operations. Due to a nominal three-year lifetime on-orbit, the initial units were replaced in February 2016. This paper will focus on the preparation and use of the AQMs over the past several years. A description of the technical aspects of the AQM will be followed by lessons learned from the deployment and operation of the first set of AQMs. These lessons were used to improve the already-excellent performance of the instruments prior to deployment of the replacement units. Data trending over the past several years of operation on ISS will also be discussed, including data obtained during a survey of the USOS modules. Finally, a description of AQM use for contingency and investigative studies will be presented.

  6. Monitoring system and methods for a distributed and recoverable digital control system

    NASA Technical Reports Server (NTRS)

    Stange, Kent (Inventor); Hess, Richard (Inventor); Kelley, Gerald B (Inventor); Rogers, Randy (Inventor)

    2010-01-01

    A monitoring system and methods are provided for a distributed and recoverable digital control system. The monitoring system generally comprises two independent monitoring planes within the control system. The first monitoring plane is internal to the computing units in the control system, and the second monitoring plane is external to the computing units. The internal first monitoring plane includes two in-line monitors. The first internal monitor is a self-checking, lock-step-processing monitor with integrated rapid recovery capability. The second internal monitor includes one or more reasonableness monitors, which compare actual effector position with commanded effector position. The external second monitor plane includes two monitors. The first external monitor includes a pre-recovery computing monitor, and the second external monitor includes a post recovery computing monitor. Various methods for implementing the monitoring functions are also disclosed.

  7. WE-D-9A-06: Open Source Monitor Calibration and Quality Control Software for Enterprise Display Management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bevins, N; Vanderhoek, M; Lang, S

    2014-06-15

    Purpose: Medical display monitor calibration and quality control present challenges to medical physicists. The purpose of this work is to demonstrate and share experiences with an open source package that allows for both initial monitor setup and routine performance evaluation. Methods: A software package, pacsDisplay, has been developed over the last decade to aid in the calibration of all monitors within the radiology group in our health system. The software is used to calibrate monitors to follow the DICOM Grayscale Standard Display Function (GSDF) via lookup tables installed on the workstation. Additional functionality facilitates periodic evaluations of both primary andmore » secondary medical monitors to ensure satisfactory performance. This software is installed on all radiology workstations, and can also be run as a stand-alone tool from a USB disk. Recently, a database has been developed to store and centralize the monitor performance data and to provide long-term trends for compliance with internal standards and various accrediting organizations. Results: Implementation and utilization of pacsDisplay has resulted in improved monitor performance across the health system. Monitor testing is now performed at regular intervals and the software is being used across multiple imaging modalities. Monitor performance characteristics such as maximum and minimum luminance, ambient luminance and illuminance, color tracking, and GSDF conformity are loaded into a centralized database for system performance comparisons. Compliance reports for organizations such as MQSA, ACR, and TJC are generated automatically and stored in the same database. Conclusion: An open source software solution has simplified and improved the standardization of displays within our health system. This work serves as an example method for calibrating and testing monitors within an enterprise health system.« less

  8. Sensor and Video Monitoring of Water Quality at Bristol Floating Harbour

    NASA Astrophysics Data System (ADS)

    Chen, Yiheng; Han, Dawei

    2017-04-01

    Water system is an essential component in a smart city for its sustainability and resilience. The harbourside is a focal area of​ ​Bristol with new buildings and features redeveloped in the last ten years, attracting numerous visitors by the diversity of attractions and beautiful views. There is a strong​ ​relationship between the satisfactory of the visitors and local people with the water quality in the Harbour. The freshness and beauty of the water body would please people as well as benefit the aquatic ecosystems. As we are entering a data-rich era, this pilot project aims to explore the concept of using​ ​ video cameras and smart sensors to collect and monitor water quality condition at the Bristol harbourside. The video cameras and smart sensors are connected to the Bristol Is Open network, an open programmable city platform. This will be the​ first​ attempt to collect water quality data in real time in the​ ​Bristol urban area with the wireless network. The videos and images of the water body collected by the cameras will be correlated with the in-situ water quality parameters for research​ ​purposes. The successful implementation of the sensors can attract more academic researchers and industrial partners to expand the sensor network to multiple locations​ ​around the city covering the other parts of the Harbour and River Avon, leading to a new generation of urban system infrastructure model.

  9. A Grid job monitoring system

    NASA Astrophysics Data System (ADS)

    Dumitrescu, Catalin; Nowack, Andreas; Padhi, Sanjay; Sarkar, Subir

    2010-04-01

    This paper presents a web-based Job Monitoring framework for individual Grid sites that allows users to follow in detail their jobs in quasi-real time. The framework consists of several independent components : (a) a set of sensors that run on the site CE and worker nodes and update a database, (b) a simple yet extensible web services framework and (c) an Ajax powered web interface having a look-and-feel and control similar to a desktop application. The monitoring framework supports LSF, Condor and PBS-like batch systems. This is one of the first monitoring systems where an X.509 authenticated web interface can be seamlessly accessed by both end-users and site administrators. While a site administrator has access to all the possible information, a user can only view the jobs for the Virtual Organizations (VO) he/she is a part of. The monitoring framework design supports several possible deployment scenarios. For a site running a supported batch system, the system may be deployed as a whole, or existing site sensors can be adapted and reused with the web services components. A site may even prefer to build the web server independently and choose to use only the Ajax powered web interface. Finally, the system is being used to monitor a glideinWMS instance. This broadens the scope significantly, allowing it to monitor jobs over multiple sites.

  10. Monitoring water quality from LANDSAT. [satellite observation of Virginia

    NASA Technical Reports Server (NTRS)

    Barker, J. L.

    1975-01-01

    Water quality monitoring possibilities from LANDSAT were demonstrated both for direct readings of reflectances from the water and indirect monitoring of changes in use of land surrounding Swift Creek Reservoir in a joint project with the Virginia State Water Control Board and NASA. Film products were shown to have insufficient resolution and all work was done by digitally processing computer compatible tapes. Land cover maps of the 18,000 hectare Swift Creek Reservoir watershed, prepared for two dates in 1974, are shown. A significant decrease in the pine cover was observed in a 740 hectare construction site within the watershed. A measure of the accuracy of classification was obtained by comparing the LANDSAT results with visual classification at five sites on a U-2 photograph. Such changes in land cover can alert personnel to watch for potential changes in water quality.

  11. The CUORE slow monitoring systems

    NASA Astrophysics Data System (ADS)

    Gladstone, L.; Biare, D.; Cappelli, L.; Cushman, J. S.; Del Corso, F.; Fujikawa, B. K.; Hickerson, K. P.; Moggi, N.; Pagliarone, C. E.; Schmidt, B.; Wagaarachchi, S. L.; Welliver, B.; Winslow, L. A.

    2017-09-01

    CUORE is a cryogenic experiment searching primarily for neutrinoless double decay in 130Te. It will begin data-taking operations in 2016. To monitor the cryostat and detector during commissioning and data taking, we have designed and developed Slow Monitoring systems. In addition to real-time systems using LabVIEW, we have an alarm, analysis, and archiving website that uses MongoDB, AngularJS, and Bootstrap software. These modern, state of the art software packages make the monitoring system transparent, easily maintainable, and accessible on many platforms including mobile devices.

  12. The CUORE slow monitoring systems

    DOE PAGES

    Gladstone, L.; Biare, D.; Cappelli, L.; ...

    2017-09-20

    CUORE is a cryogenic experiment searching primarily for neutrinoless double decay inmore » $$^{130}$$Te. It will begin data-taking operations in 2016. To monitor the cryostat and detector during commissioning and data taking, we have designed and developed Slow Monitoring systems. In addition to real-time systems using LabVIEW, we have an alarm, analysis, and archiving website that uses MongoDB, AngularJS, and Bootstrap software. These modern, state of the art software packages make the monitoring system transparent, easily maintainable, and accessible on many platforms including mobile devices.« less

  13. The CUORE slow monitoring systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gladstone, L.; Biare, D.; Cappelli, L.

    CUORE is a cryogenic experiment searching primarily for neutrinoless double decay inmore » $$^{130}$$Te. It will begin data-taking operations in 2016. To monitor the cryostat and detector during commissioning and data taking, we have designed and developed Slow Monitoring systems. In addition to real-time systems using LabVIEW, we have an alarm, analysis, and archiving website that uses MongoDB, AngularJS, and Bootstrap software. These modern, state of the art software packages make the monitoring system transparent, easily maintainable, and accessible on many platforms including mobile devices.« less

  14. 49 CFR 385.103 - Safety monitoring system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Safety monitoring system. 385.103 Section 385.103... Safety Monitoring System for Mexico-Domiciled Carriers § 385.103 Safety monitoring system. (a) General... Vehicle Safety Standards (FMVSSs), and Hazardous Materials Regulations (HMRs). (b) Roadside monitoring...

  15. 49 CFR 385.103 - Safety monitoring system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 5 2011-10-01 2011-10-01 false Safety monitoring system. 385.103 Section 385.103... Safety Monitoring System for Mexico-Domiciled Carriers § 385.103 Safety monitoring system. (a) General... Vehicle Safety Standards (FMVSSs), and Hazardous Materials Regulations (HMRs). (b) Roadside monitoring...

  16. Forested floristic quality index: An assessment tool for forested wetland habitats using the quality and quantity of woody vegetation at Coastwide Reference Monitoring System (CRMS) vegetation monitoring stations

    USGS Publications Warehouse

    Wood, William B.; Shaffer, Gary P.; Visser, Jenneke M.; Krauss, Ken W.; Piazza, Sarai C.; Sharp, Leigh Anne; Cretini, Kari F.

    2017-02-08

    The U.S. Geological Survey, in cooperation with the Coastal Protection and Restoration Authority of Louisiana and the Coastal Wetlands Planning, Protection and Restoration Act, developed the Forested Floristic Quality Index (FFQI) for the Coastwide Reference Monitoring System (CRMS). The FFQI will help evaluate forested wetland sites on a continuum from severely degraded to healthy and will assist in defining areas where forested wetland restoration can be successful by projecting the trajectories of change. At each CRMS forested wetland site there are stations for quantifying the overstory, understory, and herbaceous vegetation layers. Rapidly responding overstory canopy cover and herbaceous layer composition are measured annually, while gradually changing overstory basal area and species composition are collected on a 3-year cycle.A CRMS analytical team has tailored these data into an index much like the Floristic Quality Index (FQI) currently used for herbaceous marsh and for the herbaceous layer of the swamp vegetation. The core of the FFQI uses basal area by species to assess the quality and quantity of the overstory at each of three stations within each CRMS forested wetland site. Trees that are considered by experts to be higher quality swamp species like Taxodium distichum (bald cypress) and Nyssa aquatica (water tupelo) are scored higher than tree species like Triadica sebifera (Chinese tallow) and Salix nigra (black willow) that are indicators of recent disturbance. This base FFQI is further enhanced by the percent canopy cover in the overstory and the presence of indicator species at the forest floor. This systemic approach attempts to differentiate between locations with similar basal areas that are on different ecosystem trajectories. Because of these varying states of habitat degradation, paired use of the FQI and the FFQI is useful to interpret the vegetative data in transitional locations. There is often an inverse relation between the health of the

  17. Nekton Interaction Monitoring System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2017-03-15

    The software provides a real-time processing system for sonar to detect and track animals, and to extract water column biomass statistics in order to facilitate continuous monitoring of an underwater environment. The Nekton Interaction Monitoring System (NIMS) extracts and archives tracking and backscatter statistics data from a real-time stream of data from a sonar device. NIMS also sends real-time tracking messages over the network that can be used by other systems to generate other metrics or to trigger instruments such as an optical video camera. A web-based user interface provides remote monitoring and control. NIMS currently supports three popular sonarmore » devices: M3 multi-beam sonar (Kongsberg), EK60 split-beam echo-sounder (Simrad) and BlueView acoustic camera (Teledyne).« less

  18. Framework for a ground-water quality monitoring and assessment program for California

    USGS Publications Warehouse

    Belitz, Kenneth; Dubrovsky, Neil M.; Burow, Karen; Jurgens, Bryant C.; John, Tyler

    2003-01-01

    The State of California uses more ground water than any other State in the Nation. With a population of over 30 million people, an agricultural economy based on intensive irrigation, large urban industrial areas, and naturally elevated concentrations of some trace elements, there is a wide range of contaminant sources that have the potential to contaminate ground water and limit its beneficial uses. In response to the many-and different-potential sources of ground-water contamination, the State of California has evolved an extensive set of rules and programs to protect ground-water quality, and agencies to implement the rules and programs. These programs have in common a focus on compliance with regulations governing chemical use and (or) ground-water quality. Although appropriate for, and successful at, their specific missions, these programs do not at present provide a comprehensive view of ground-water quality in the State of California. In October 2001, The California Assembly passed a bill, AB 599, establishing the Ground-Water- Quality Monitoring Act of 2001.' The goal of AB 599 is to improve Statewide comprehensive ground-water monitoring and increase availability of information about ground-water quality to the public. AB 599 requires the State Water Resources Control Board (SWRCB), in collaboration with an interagency task force (ITF) and a public advisory committee (PAC), to develop a plan for a comprehensive ground-water monitoring program. AB 599 specifies that the comprehensive program should be capable of assessing each ground-water basin in the State through direct and other statistically reliable sampling approaches, and that the program should integrate existing monitoring programs and design new program elements, as necessary. AB 599 also stresses the importance of prioritizing ground-water basins that provide drinking water. The United States Geological Survey (USGS), in cooperation with the SWRCB, and in coordination with the ITF and PAC, has

  19. Progress toward a ground-water-quality monitoring network for Idaho

    USGS Publications Warehouse

    Whitehead, R.L.

    1978-01-01

    The potential for pollution of the aquifers is expected to be greatest in areas of greatest development. In Idaho, population centers and industries tend to be in areas of privately owned irrigated and arable · land. Therefore, these areas are of primary concern for monitoring ground-water quality. Other areas requiring monitoring include those with second-home development, mining and its related processes, and radioactive-waste disposal.

  20. Basic Information about Air Emissions Monitoring

    EPA Pesticide Factsheets

    This site is about types of air emissions monitoring and the Clean Air Act regulations, including Ambient Air Quality Monitoring, Stationary Source Emissions Monitoring, and Continuous Monitoring Systems.

  1. 49 CFR 385.703 - Safety monitoring system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Safety monitoring system. 385.703 Section 385.703... Safety Monitoring System for Non-North American Carriers § 385.703 Safety monitoring system. (a) General... Vehicle Safety Standards (FMVSSs), and Hazardous Materials Regulations (HMRs). (b) Roadside monitoring...

  2. 49 CFR 385.703 - Safety monitoring system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 5 2011-10-01 2011-10-01 false Safety monitoring system. 385.703 Section 385.703... Safety Monitoring System for Non-North American Carriers § 385.703 Safety monitoring system. (a) General... Vehicle Safety Standards (FMVSSs), and Hazardous Materials Regulations (HMRs). (b) Roadside monitoring...

  3. Challenges for implementing water quality monitoring and analysis on a small Costa Rican catchment

    NASA Astrophysics Data System (ADS)

    Golcher, Christian; Cernesson, Flavie; Tournoud, Marie-George; Bonin, Muriel; Suarez, Andrea

    2016-04-01

    The Costa Rican water regulatory framework (WRF) (2007), expresses the national concern about the degradation of surface water quality observed in the country since several years. Given the urgency of preserving and restoring the surface water bodies, and facing the need of defining a monitoring tool to classify surface water pollution, the Costa-Rican WRF relies on two water quality indexes: the so-called "Dutch Index" (D.I) and the Biological Monitoring Working Party adapted to Costa Rica (BMWP'CR), allowing an "easy" physicochemical and biological appraisal of the water quality and the ecological integrity of water bodies. Herein, we intend to evaluate whether the compound of water quality indexes imposed by Costa Rican legislation, is suitable to assess rivers local and global anthropogenic pressure and environmental conditions. We monitor water quality for 7 points of Liberia River (northern pacific region - Costa Rica) from March 2013 to July 2015. Anthropogenic pressures are characterized by catchment land use and riparian conditions. Environmental conditions are built from rainfall daily series. Our results show (i) the difficulties to monitor new sites following the recent implementation of the WRF; (ii) the statistical characteristics of each index; and (iii) a modelling tentative of relationships between water quality indexes and explanatory factors (land-use, riparian characteristics and climate conditions).

  4. Development of living body information monitoring system

    NASA Astrophysics Data System (ADS)

    Sakamoto, Hidetoshi; Ohbuchi, Yoshifumi; Torigoe, Ippei; Miyagawa, Hidekazu; Murayama, Nobuki; Hayashida, Yuki; Igasaki, Tomohiko

    2010-03-01

    The easy monitoring systems of contact and non-contact living body information for preventing the the Sudden Infant Death Syndrome (SIDS) were proposed as an alternative monitoring system of the infant's vital information. As for the contact monitoring system, respiration sensor, ECG electrodes, thermistor and IC signal processor were integrated into babies' nappy holder. This contact-monitoring unit has RF transmission function and the obtained data are analyzed in real time by PC. In non-contact mortaring system, the infrared thermo camera was used. The surrounding of the infant's mouth and nose is monitored and the respiration rate is obtained by thermal image processing of its temperature change image of expired air. This proposed system of in-sleep infant's vital information monitoring system and unit are very effective as not only infant's condition monitoring but also nursing person's one.

  5. Development of living body information monitoring system

    NASA Astrophysics Data System (ADS)

    Sakamoto, Hidetoshi; Ohbuchi, Yoshifumi; Torigoe, Ippei; Miyagawa, Hidekazu; Murayama, Nobuki; Hayashida, Yuki; Igasaki, Tomohiko

    2009-12-01

    The easy monitoring systems of contact and non-contact living body information for preventing the the Sudden Infant Death Syndrome (SIDS) were proposed as an alternative monitoring system of the infant's vital information. As for the contact monitoring system, respiration sensor, ECG electrodes, thermistor and IC signal processor were integrated into babies' nappy holder. This contact-monitoring unit has RF transmission function and the obtained data are analyzed in real time by PC. In non-contact mortaring system, the infrared thermo camera was used. The surrounding of the infant's mouth and nose is monitored and the respiration rate is obtained by thermal image processing of its temperature change image of expired air. This proposed system of in-sleep infant's vital information monitoring system and unit are very effective as not only infant's condition monitoring but also nursing person's one.

  6. Identifying perceived barriers to monitoring service quality among substance abuse treatment providers in South Africa

    PubMed Central

    2014-01-01

    Background A performance measurement system is planned for South African substance abuse treatment services. Provider-level barriers to implementing these systems have been identified in the United States, but little is known about the nature of these barriers in South Africa. This study explored the willingness of South African substance abuse treatment providers’ to adopt a performance measurement system and perceived barriers to monitoring service quality that would need to be addressed during system development. Methods Three focus group discussions were held with treatment providers from two of the nine provinces in South Africa. These providers represented the diverse spread of substance abuse treatment services available in the country. The final sample comprised 21 representatives from 12 treatment facilities: eight treatment centres in the Western Cape and four in KwaZulu-Natal. Content analysis was used to extract core themes from these discussions. Results Participants identified barriers to the monitoring of service quality that included outdated modes of collecting data, personnel who were already burdened by paperwork, lack of time to collect data, and limited skills to analyse and interpret data. Participants recommended that developers engage with service providers in a participatory manner to ensure that service providers are invested in the proposed performance measurement system. Conclusion Findings show that substance abuse treatment providers are willing to adopt a performance measurement system and highlight several barriers that need to be addressed during system development in order to enhance the likelihood that this system will be successfully implemented. PMID:24499037

  7. Control and monitoring method and system for electromagnetic forming process

    DOEpatents

    Kunerth, Dennis C.; Lassahn, Gordon D.

    1990-01-01

    A process, system, and improvement for a process for electromagnetic forming of a workpiece in which characteristics of the workpiece such as its geometry, electrical conductivity, quality, and magnetic permeability can be determined by monitoring the current and voltage in the workcoil. In an electromagnet forming process in which a power supply provides current to a workcoil and the electromagnetic field produced by the workcoil acts to form the workpiece, the dynamic interaction of the electromagnetic fields produced by the workcoil with the geometry, electrical conductivity, and magnetic permeability of the workpiece, provides information pertinent to the physical condition of the workpiece that is available for determination of quality and process control. This information can be obtained by deriving in real time the first several time derivatives of the current and voltage in the workcoil. In addition, the process can be extended by injecting test signals into the workcoil during the electromagnetic forming and monitoring the response to the test signals in the workcoil.

  8. A Systems Approach to Manage Drinking Water Quality ...

    EPA Pesticide Factsheets

    Drinking water supplies can be vulnerable to impacts from short-term weather events, long-term changes in land-use and climate, and water quality controls in treatment and distribution. Disinfection by-product (DBP) formation in drinking water is a prominent example to illustrate the water supply vulnerability and examine technological options in adaptation. Total organic carbon (TOC) in surface water can vary significantly due to changes or a combination of changes in watershed land use, climate variability, and extreme meteorological events (e.g., hurricanes). On the other hand, water demand is known to vary temporarily and spatially leading to changes in water ages and hence DBP formation potential. Typically a drinking water facility is designed to operate within a projected range of influent water quality and water demand. When the variations exceed the design range, water supply becomes vulnerable in the compliance to Safe Drinking Water Act (SDWA) Stage-II disinfection by-product (DBP) rules. This paper describes a framework of systems-level modeling, monitoring and control in adaptive planning and system operation. The framework, built upon the integration of model projections, adaptive monitoring and systems control, has three primary functions. Its advantages and limitations will be discussed with the application examples in Cincinnati (Ohio, USA) and Las Vegas (Nevada, USA). At a conceptual level, an integrated land use and hydrological model

  9. Water Quality Monitor

    NASA Technical Reports Server (NTRS)

    1979-01-01

    In the photo above, the cylindrical container being lowered into the water is a water quality probe developed by NASA's Langley Research Center for the Environmental Protection Agency (EPA) in an applications engineering project. It is part of a system- which also includes recording equipment in the helicopter-for on-the-spot analysis of water samples. It gives EPA immediate and more accurate information than the earlier method, in which samples are transported to a lab for analysis. Designed primarily for rapid assessment of hazardous spills in coastal and inland waters, the system provides a wide range of biological and chemical information relative to water pollution.

  10. Image processing developments and applications for water quality monitoring and trophic state determination

    NASA Technical Reports Server (NTRS)

    Blackwell, R. J.

    1982-01-01

    Remote sensing data analysis of water quality monitoring is evaluated. Data anaysis and image processing techniques are applied to LANDSAT remote sensing data to produce an effective operational tool for lake water quality surveying and monitoring. Digital image processing and analysis techniques were designed, developed, tested, and applied to LANDSAT multispectral scanner (MSS) data and conventional surface acquired data. Utilization of these techniques facilitates the surveying and monitoring of large numbers of lakes in an operational manner. Supervised multispectral classification, when used in conjunction with surface acquired water quality indicators, is used to characterize water body trophic status. Unsupervised multispectral classification, when interpreted by lake scientists familiar with a specific water body, yields classifications of equal validity with supervised methods and in a more cost effective manner. Image data base technology is used to great advantage in characterizing other contributing effects to water quality. These effects include drainage basin configuration, terrain slope, soil, precipitation and land cover characteristics.

  11. A New Era of Air Quality Monitoring from Space in East Asia: Korea's Geostationary Environmental Monitoring Spectrometer (GEMS) and an Integrated Korea-US Air Quality (KORUS-AQ) Study

    NASA Astrophysics Data System (ADS)

    Hong, J.; Hong, Y.; Song, C. K.; Kim, S. K.; Chang, L. S.; Lim, J.; Ahn, J.; Park, J. H.; Kim, J. Y.; Han, Y. J.; Kim, J.; Park, R.; Lee, G.; Lefer, B. L.; Al-Saadi, J. A.; Crawford, J. H.

    2015-12-01

    Due to remarkable economic growth over the last two decades, East Asia has become a region experiencing some of the poorest air quality in the world. In addition to local sources of pollution, the Korea peninsula is downwind of the largest emission sources in East Asia, complicating the understanding of air quality over Korea. Thus, knowing the factors controlling changes in air pollution across urban-rural and marine-continental interfaces, in addition to the contributions from local emissions and transboundary transport, is important for building effective management strategies and improving air quality in East Asia. GEMS (Geostationary Environmental Monitoring Spectrometer) is a satellite instrument planned for launch in 2019 by the Republic of Korea. The instrument will observe East Asia and the western Pacific region, providing real-time monitoring of air quality (e.g. O3, NO2, SO2, HCHO, AOD, etc.) and enabling better scientific understanding of the transboundary transport of air pollutants. The KORUS-AQ (the Korea and U.S. Air Quality) field campaign will take place in May - June 2016 and will employ an integrated observing strategy including multiplatform observations (i.e. ground stations, aircraft, ships, and satellites) and chemical transport models. This mission aims to not only strengthen our knowledge of atmospheric chemistry but also provide important data sets for validating GEMS retrieval algorithms. In preparation for KORUS-AQ, a pre-campaign has been successfully conducted in Korea during early summer 2015 with observations from multiple ground sites and a small aircraft. A brief summary of pre-field campaign results will be presented. Moving forward, the GEMS mission and KORUS-AQ study will lead to a new era of air quality monitoring in East Asia. GEMS will also make critical contributions to the global air quality perspective working in concert with geostationary missions launched by the U.S. (TEMPO: Tropospheric Emissions: Monitoring of

  12. Sustainable microbial water quality monitoring programme design using phage-lysis and multivariate techniques.

    PubMed

    Nnane, Daniel Ekane

    2011-11-15

    Contamination of surface waters is a pervasive threat to human health, hence, the need to better understand the sources and spatio-temporal variations of contaminants within river catchments. River catchment managers are required to sustainably monitor and manage the quality of surface waters. Catchment managers therefore need cost-effective low-cost long-term sustainable water quality monitoring and management designs to proactively protect public health and aquatic ecosystems. Multivariate and phage-lysis techniques were used to investigate spatio-temporal variations of water quality, main polluting chemophysical and microbial parameters, faecal micro-organisms sources, and to establish 'sentry' sampling sites in the Ouse River catchment, southeast England, UK. 350 river water samples were analysed for fourteen chemophysical and microbial water quality parameters in conjunction with the novel human-specific phages of Bacteroides GB-124 (Bacteroides GB-124). Annual, autumn, spring, summer, and winter principal components (PCs) explained approximately 54%, 75%, 62%, 48%, and 60%, respectively, of the total variance present in the datasets. Significant loadings of Escherichia coli, intestinal enterococci, turbidity, and human-specific Bacteroides GB-124 were observed in all datasets. Cluster analysis successfully grouped sampling sites into five clusters. Importantly, multivariate and phage-lysis techniques were useful in determining the sources and spatial extent of water contamination in the catchment. Though human faecal contamination was significant during dry periods, the main source of contamination was non-human. Bacteroides GB-124 could potentially be used for catchment routine microbial water quality monitoring. For a cost-effective low-cost long-term sustainable water quality monitoring design, E. coli or intestinal enterococci, turbidity, and Bacteroides GB-124 should be monitored all-year round in this river catchment. Copyright © 2011 Elsevier B.V. All

  13. Quality management systems for your in vitro fertilization clinic's laboratory: Why bother?

    PubMed

    Olofsson, Jan I; Banker, Manish R; Sjoblom, Late Peter

    2013-01-01

    Several countries have in recent years introduced prescribed requirements for treatment and monitoring of outcomes, as well as a licensing or accreditation requirement for in vitro fertilization (IVF) clinics and their laboratories. It is commonplace for Assisted Reproductive Technology (ART) laboratories to be required to have a quality control system. However, more effective Total Quality Management systems are now being implemented by an increasing number of ART clinics. In India, it is now a requirement to have a quality management system in order to be accredited and to help meet customer demand for improved delivery of ART services. This review contains the proceedings a quality management session at the Indian Fertility Experts Meet (IFEM) 2010 and focuses on the creation of a patient-oriented best-in-class IVF laboratory.

  14. Quality management systems for your in vitro fertilization clinic's laboratory: Why bother?

    PubMed Central

    Olofsson, Jan I; Banker, Manish R; Sjoblom, Late Peter

    2013-01-01

    Several countries have in recent years introduced prescribed requirements for treatment and monitoring of outcomes, as well as a licensing or accreditation requirement for in vitro fertilization (IVF) clinics and their laboratories. It is commonplace for Assisted Reproductive Technology (ART) laboratories to be required to have a quality control system. However, more effective Total Quality Management systems are now being implemented by an increasing number of ART clinics. In India, it is now a requirement to have a quality management system in order to be accredited and to help meet customer demand for improved delivery of ART services. This review contains the proceedings a quality management session at the Indian Fertility Experts Meet (IFEM) 2010 and focuses on the creation of a patient-oriented best-in-class IVF laboratory. PMID:23869142

  15. Inductive System Monitors Tasks

    NASA Technical Reports Server (NTRS)

    2008-01-01

    The Inductive Monitoring System (IMS) software developed at Ames Research Center uses artificial intelligence and data mining techniques to build system-monitoring knowledge bases from archived or simulated sensor data. This information is then used to detect unusual or anomalous behavior that may indicate an impending system failure. Currently helping analyze data from systems that help fly and maintain the space shuttle and the International Space Station (ISS), the IMS has also been employed by data classes are then used to build a monitoring knowledge base. In real time, IMS performs monitoring functions: determining and displaying the degree of deviation from nominal performance. IMS trend analyses can detect conditions that may indicate a failure or required system maintenance. The development of IMS was motivated by the difficulty of producing detailed diagnostic models of some system components due to complexity or unavailability of design information. Successful applications have ranged from real-time monitoring of aircraft engine and control systems to anomaly detection in space shuttle and ISS data. IMS was used on shuttle missions STS-121, STS-115, and STS-116 to search the Wing Leading Edge Impact Detection System (WLEIDS) data for signs of possible damaging impacts during launch. It independently verified findings of the WLEIDS Mission Evaluation Room (MER) analysts and indicated additional points of interest that were subsequently investigated by the MER team. In support of the Exploration Systems Mission Directorate, IMS is being deployed as an anomaly detection tool on ISS mission control consoles in the Johnson Space Center Mission Operations Directorate. IMS has been trained to detect faults in the ISS Control Moment Gyroscope (CMG) systems. In laboratory tests, it has already detected several minor anomalies in real-time CMG data. When tested on archived data, IMS was able to detect precursors of the CMG1 failure nearly 15 hours in advance of

  16. Using lot quality assurance sampling to assess measurements for growth monitoring in a developing country's primary health care system.

    PubMed

    Valadez, J J; Brown, L D; Vargas, W V; Morley, D

    1996-04-01

    Local supervisors used lot quality assurance sampling (LQAS) during routine household visits to assess the technical quality of Costa Rican community-based health workers (CHW): measuring and recording weights of children, interpreting their growth trend and providing nutrition education to mothers. Supervisors sampled 10 households in each of 12 Health Areas (4-8 hours per area). No more than two performance errors were allowed for each CHW. This LQAS decision rule resulted in judgments with a sensitivity and specificity of about 95 percent. Three categories of results are reported: (1) CHW adequately weighed children, calculated ages, identified children requiring nutritional services, and used the growth chart. (2) They needed to improve referral, education, and documentation skills. (3) The lack of system support to regularly provide growth cards, supplementary feeding to identified malnourished children, and other essential materials may have discouraged some CHW resulting in them not applying their skills. Supervisors regularly using LQAS should, by the sixth round of supervision, identify at least 90 percent of inadequately performing CHW. This paper demonstrates the strength of LQAS, namely, to be used easily by low level local health workers to identify poorly functioning components of growth monitoring and promotion.

  17. DATA QUALITY OBJECTIVES-FOUNDATION OF A SUCCESSFUL MONITORING PROGRAM

    EPA Science Inventory

    The data quality objectives (DQO) process is a fundamental site characterization tool and the foundation of a successful monitoring program. The DQO process is a systematic planning approach based on the scientific method of inquiry. The process identifies the goals of data col...

  18. Groundwater Monitoring Plan. Volume 2. Final Quality Assurance Project Plan

    DTIC Science & Technology

    1993-10-01

    5 Table 4-2. US EPA Drinking Water MCLs ........................................ 4-6 Table 5-1. Sample Bottle Requirements, Preservation, and Holding... drinking water . " The types of quality control samples that will be collected during the Canal Creek groundwater monitoring program. ]- Jacobs...Revision No.: 0 Date: 10/27/93 Page: 6 of 9 Canal Creek Area, APG-EA, Maryland Groundwater Monitoring Plan, VOLUME I1 Table 4-2. US EPA Drinking Water

  19. Conducting remote bioanalytical data monitoring and review based on scientific quality objectives.

    PubMed

    He, Ling

    2011-07-01

    For bioanalytical laboratories that follow GLP regulations and generate data for new drug filing, ensuring quality standards set by regulatory guidance is a fundamental expectation. Numerous guidelines and White Papers have been published by regulatory agencies, professional working groups and field experts in the past two decades, and have significantly improved the standards of good practices for bioanalysis. From a sponsor's perspective, continuous quality monitoring of the data generated by CRO laboratories, identifying adverse trends and taking corrective and preventative actions against issues encountered, are critical aspects of effective bioanalytical outsourcing management. This is especially important for clinical bioanalysis, where one validated assay is applied for analyzing a large number of samples of diverse demographics and disease states. This perspective article presents thoughts toward remote data monitoring and its merits for scientific quality oversight, and introduces a novel Bioanalytical Data Review software that was custom-developed and platform-neural, to conduct remote data monitoring on raw or processed LC-MS/MS data from CROs. Flexible, adaptive and user-customizable queries are applied for conducting project-, batch- and sample-level data review based on scientific quality performance factors commonly assessed for good bioanalytical practice.

  20. Performance Monitoring Applied to System Supervision

    PubMed Central

    Somon, Bertille; Campagne, Aurélie; Delorme, Arnaud; Berberian, Bruno

    2017-01-01

    Nowadays, automation is present in every aspect of our daily life and has some benefits. Nonetheless, empirical data suggest that traditional automation has many negative performance and safety consequences as it changed task performers into task supervisors. In this context, we propose to use recent insights into the anatomical and neurophysiological substrates of action monitoring in humans, to help further characterize performance monitoring during system supervision. Error monitoring is critical for humans to learn from the consequences of their actions. A wide variety of studies have shown that the error monitoring system is involved not only in our own errors, but also in the errors of others. We hypothesize that the neurobiological correlates of the self-performance monitoring activity can be applied to system supervision. At a larger scale, a better understanding of system supervision may allow its negative effects to be anticipated or even countered. This review is divided into three main parts. First, we assess the neurophysiological correlates of self-performance monitoring and their characteristics during error execution. Then, we extend these results to include performance monitoring and error observation of others or of systems. Finally, we provide further directions in the study of system supervision and assess the limits preventing us from studying a well-known phenomenon: the Out-Of-the-Loop (OOL) performance problem. PMID:28744209

  1. [Intelligent watch system for health monitoring based on Bluetooth low energy technology].

    PubMed

    Wang, Ji; Guo, Hailiang; Ren, Xiaoli

    2017-08-01

    According to the development status of wearable technology and the demand of intelligent health monitoring, we studied the multi-function integrated smart watches solution and its key technology. First of all, the sensor technology with high integration density, Bluetooth low energy (BLE) and mobile communication technology were integrated and used in develop practice. Secondly, for the hardware design of the system in this paper, we chose the scheme with high integration density and cost-effective computer modules and chips. Thirdly, we used real-time operating system FreeRTOS to develop the friendly graphical interface interacting with touch screen. At last, the high-performance application software which connected with BLE hardware wirelessly and synchronized data was developed based on android system. The function of this system included real-time calendar clock, telephone message, address book management, step-counting, heart rate and sleep quality monitoring and so on. Experiments showed that the collecting data accuracy of various sensors, system data transmission capacity, the overall power consumption satisfy the production standard. Moreover, the system run stably with low power consumption, which could realize intelligent health monitoring effectively.

  2. Reactor Operations Monitoring System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hart, M.M.

    1989-01-01

    The Reactor Operations Monitoring System (ROMS) is a VME based, parallel processor data acquisition and safety action system designed by the Equipment Engineering Section and Reactor Engineering Department of the Savannah River Site. The ROMS will be analyzing over 8 million signal samples per minute. Sixty-eight microprocessors are used in the ROMS in order to achieve a real-time data analysis. The ROMS is composed of multiple computer subsystems. Four redundant computer subsystems monitor 600 temperatures with 2400 thermocouples. Two computer subsystems share the monitoring of 600 reactor coolant flows. Additional computer subsystems are dedicated to monitoring 400 signals from assortedmore » process sensors. Data from these computer subsystems are transferred to two redundant process display computer subsystems which present process information to reactor operators and to reactor control computers. The ROMS is also designed to carry out safety functions based on its analysis of process data. The safety functions include initiating a reactor scram (shutdown), the injection of neutron poison, and the loadshed of selected equipment. A complete development Reactor Operations Monitoring System has been built. It is located in the Program Development Center at the Savannah River Site and is currently being used by the Reactor Engineering Department in software development. The Equipment Engineering Section is designing and fabricating the process interface hardware. Upon proof of hardware and design concept, orders will be placed for the final five systems located in the three reactor areas, the reactor training simulator, and the hardware maintenance center.« less

  3. Bedside arterial blood gas monitoring system using fluorescent optical sensors

    NASA Astrophysics Data System (ADS)

    Bartnik, Daniel J.; Rymut, Russell A.

    1995-05-01

    We describe a bedside arterial blood gas (ABG) monitoring system which uses fluorescent optical sensors in the measurement of blood pH, PCO2 and PO2. The Point-of-Care Arterial Blood Gas Monitoring System consists of the SensiCathTM optical sensor unit manufactured by Optical Sensors Incorporated and the TramTM Critical Care Monitoring System with ABG Module manufactured by Marquette Electronics Incorporated. Current blood gas measurement techniques require a blood sample to be removed from the patient and transported to an electrochemical analyzer for analysis. The ABG system does not require removal of blood from the patient or transport of the sample. The sensor is added to the patient's existing arterial line. ABG measurements are made by drawing a small blood sample from the arterial line in sufficient quantity to ensure an undiluted sample at the sensor. Measurements of pH, PCO2 and PO2 are made within 60 seconds. The blood is then returned to the patient, the line flushed and results appear on the bedside monitor. The ABG system offers several advantages over traditional electrochemical analyzers. Since the arterial line remains closed during the blood sampling procedure the patient's risk of infection is reduced and the caregiver's exposure to blood is eliminated. The single-use, disposable sensor can be measure 100 blood samples over 72 hours after a single two-point calibration. Quality Assurance checks are also available and provide the caregiver the ability to assess system performance even after the sensor is patient attached. The ABG module integrates with an existing bedside monitoring system. This allows ABG results to appear on the same display as ECG, respiration, blood pressure, cardiac output, SpO2, and other clinical information. The small module takes up little space in the crowded intensive care unit. Performance studies compare the ABG system with an electrochemical blood gas analyzer. Study results demonstrated accurate and precise blood

  4. [Ophthalmological service quality offered to outpatients of the Public Healthcare System].

    PubMed

    Santos Hercos, Benigno Vicente; Berezovsky, Adriana

    2006-01-01

    To identify the perception of the ophthalmic service quality provided for outpatients of the public healthcare system as well as to detect which actions should be considered necessary and priority in order to improve its quality. A quantitative descriptive study was carried out on 100 outpatients of the public healthcare system which were submitted to ophthalmic tests at Fundação Hilton Rocha--Belo Horizonte-MG, from July 1st-July 30th 2004. Individual interviews were carried out by giving the interviewees two structured questionnaires adapted from the modified SERVQUAL. This scale is in agreement with the reality of the studied institute. The adapted SERVQUAL scale was submitted to statistical validation and it showed a suitable internal consistency index. In general terms, a slight general dissatisfaction was detected regarding ophthalmological service quality. The interviewees cared more about safety and reliability. A higher degree of dissatisfaction was detected mainly concerning fulfillment of procedures at scheduled appointments related to the execution of services within due time-limits. The institute is supposed to plan as well as carry out actions which lead to a general improvement in the patient's satisfaction regarding service quality and mainly reliability. Service quality monitoring through periodic use of the SERVQUAL scale will not only make it possible to plan highly precise and effective intervention strategies in these and in other healthcare services but it will also allow monitoring the responses to these actions. All these actions will contribute to the improvement of the service in the system as a whole.

  5. [A new method for safety monitoring of natural dietary supplements--quality profile].

    PubMed

    Wang, Juan; Wang, Li-Ping; Yang, Da-Jin; Chen, Bo

    2008-07-01

    A new method for safety monitoring of natural dietary supplements--quality profile was proposed. It would convert passive monitoring of synthetic drug to active, and guarantee the security of natural dietary supplements. Preliminary research on quality profile was completed by high performance liquid chromatography (HPLC) and mass spectrometry (MS). HPLC was employed to analyze chemical constituent profiles of natural dietary supplements. The separation was completed on C18 column with acetonitrile and water (0.05% H3PO4) as mobile phase, the detection wavelength was 223 nm. Based on HPLC, stability of quality profile had been studied, and abnormal compounds in quality profile had been analyzed after addition of phenolphthalein, sibutramine, rosiglitazone, glibenclamide and gliclazide. And by MS, detector worked with ESI +, capillary voltage: 3.5 kV, cone voltage: 30 V, extractor voltage: 4 V, RF lens voltage: 0.5 V, source temperature: 105 degrees C, desolvation temperature: 300 degrees C, desolvation gas flow rate: 260 L/h, cone gas flow rate: 50 L/h, full scan mass spectra: m/z 100-600. Abnormal compound in quality profile had been analyzed after addition of N-mono-desmethyl sibutramine. Quality profile based on HPLC had good stability (Similarity > 0.877). Addition of phenolphthalein, sibutramine, rosiglitazone, glibenclamide and gliclazide in natural dietary supplements could be reflected by HPLC, and addition of N-mono-desmethyl sibutramine in natural dietary supplements could be reflected by MS. Quality profile might monitor adulteration of natural dietary supplements, and prevent addition of synthetic drug after "approval".

  6. Processing and Quality Monitoring for the ATLAS Tile Hadronic Calorimeter Data

    NASA Astrophysics Data System (ADS)

    Burghgrave, Blake; ATLAS Collaboration

    2017-10-01

    An overview is presented of Data Processing and Data Quality (DQ) Monitoring for the ATLAS Tile Hadronic Calorimeter. Calibration runs are monitored from a data quality perspective and used as a cross-check for physics runs. Data quality in physics runs is monitored extensively and continuously. Any problems are reported and immediately investigated. The DQ efficiency achieved was 99.6% in 2012 and 100% in 2015, after the detector maintenance in 2013-2014. Changes to detector status or calibrations are entered into the conditions database (DB) during a brief calibration loop between the end of a run and the beginning of bulk processing of data collected in it. Bulk processed data are reviewed and certified for the ATLAS Good Run List if no problem is detected. Experts maintain the tools used by DQ shifters and the calibration teams during normal operation, and prepare new conditions for data reprocessing and Monte Carlo (MC) production campaigns. Conditions data are stored in 3 databases: Online DB, Offline DB for data and a special DB for Monte Carlo. Database updates can be performed through a custom-made web interface.

  7. Protocol and Demonstrations of Probabilistic Reliability Assessment for Structural Health Monitoring Systems (Preprint)

    DTIC Science & Technology

    2011-11-01

    assessment to quality of localization/characterization estimates. This protocol includes four critical components: (1) a procedure to identify the...critical factors impacting SHM system performance; (2) a multistage or hierarchical approach to SHM system validation; (3) a model -assisted evaluation...Lindgren, E. A ., Buynak, C. F., Steffes, G., Derriso, M., “ Model -assisted Probabilistic Reliability Assessment for Structural Health Monitoring

  8. Sports Injury Surveillance Systems: A Review of Methods and Data Quality.

    PubMed

    Ekegren, Christina L; Gabbe, Belinda J; Finch, Caroline F

    2016-01-01

    Data from sports injury surveillance systems are a prerequisite to the development and evaluation of injury prevention strategies. This review aimed to identify ongoing sports injury surveillance systems and determine whether there are gaps in our understanding of injuries in certain sport settings. A secondary aim was to determine which of the included surveillance systems have evaluated the quality of their data, a key factor in determining their usefulness. A systematic search was carried out to identify (1) publications presenting methodological details of sports injury surveillance systems within clubs and organisations; and (2) publications describing quality evaluations and the quality of data from these systems. Data extracted included methodological details of the surveillance systems, methods used to evaluate data quality, and results of these evaluations. Following literature search and review, a total of 15 sports injury surveillance systems were identified. Data relevant to each aim were summarised descriptively. Most systems were found to exist within professional and elite sports. Publications concerning data quality were identified for seven (47%) systems. Validation of system data through comparison with alternate sources has been undertaken for only four systems (27%). This review identified a shortage of ongoing injury surveillance data from amateur and community sport settings and limited information about the quality of data in professional and elite settings. More surveillance systems are needed across a range of sport settings, as are standards for data quality reporting. These efforts will enable better monitoring of sports injury trends and the development of sports safety strategies.

  9. Real time high frequency monitoring of water quality in river streams using a UV-visible spectrometer: interest, limits and consequences for monitoring strategies

    NASA Astrophysics Data System (ADS)

    Faucheux, Mikaël; Fovet, Ophélie; Gruau, Gérard; Jaffrézic, Anne; Petitjean, Patrice; Gascuel-Odoux, Chantal; Ruiz, Laurent

    2013-04-01

    Stream water chemistry is highly variable in space and time, therefore high frequency water quality measurement methods are likely to lead to conceptual advances in the hydrological sciences. Sub-daily data on water quality improve the characterization of pollutant sources and pathways during flood events as well as during long-term periods [1]. However, real time, high frequency monitoring devices needs to be properly calibrated and validated in real streams. This study analyses data from in situ monitoring of a stream water quality. During two hydrological years (2010-11, 2011-12), a submersible UV-visible spectrometer (Scan Spectrolyser) was used for surface water quality measurement at the outlet of a headwater catchment located at Kervidy-Naizin, Western France (AgrHys long-term hydrological observatory, http://www.inra.fr/ore_agrhys/). The spectrometer is reagentless and equipped with an auto-cleaning system. It allows real time, in situ and high frequency (20 min) measurements and uses a multiwavelengt spectral (200-750 nm) for simultaneous measurement of nitrate, dissolved organic carbon (DOC) and total suspended solids (TSS). A global calibration based on a PLS (Partial Least Squares) regression is provided by the manufacturer as default configuration of the UV-visible spectrometer. We carried out a local calibration of the spectrometer based on nitrates and DOC concentrations analysed in the laboratory from daily manual sampling and sub-daily automatic sampling of flood events. TSS results are compared with 15 min turbidity records from a continuous turdidimeter (Ponsel). The results show a good correlation between laboratory data and spectrometer data both during basis flows periods and flood events. However, the local calibration gives better results than the global one. Nutrient fluxes estimates based on high and different low frequency time series (daily to monthly) are compared to discuss the implication for environmental monitoring strategies. Such

  10. The Chandra Monitoring System

    NASA Astrophysics Data System (ADS)

    Wolk, S. J.; Petreshock, J. G.; Allen, P.; Bartholowmew, R. T.; Isobe, T.; Cresitello-Dittmar, M.; Dewey, D.

    The NASA Great Observatory Chandra was launched July 23, 1999 aboard the space shuttle Columbia. The Chandra Science Center (CXC) runs a monitoring and trends analysis program to maximize the science return from this mission. At the time of the launch, the monitoring portion of this system was in place. The system is a collection of multiple threads and programming methodologies acting cohesively. Real-time data are passed to the CXC. Our real-time tool, ACORN (A Comprehensive object-ORiented Necessity), performs limit checking of performance related hardware. Chandra is in ground contact less than 3 hours a day, so the bulk of the monitoring must take place on data dumped by the spacecraft. To do this, we have written several tools which run off of the CXC data system pipelines. MTA_MONITOR_STATIC, limit checks FITS files containing hardware data. MTA_EVENT_MON and MTA_GRAT_MON create quick look data for the focal place instruments and the transmission gratings. When instruments violate their operational limits, the responsible scientists are notified by email and problem tracking is initiated. Output from all these codes is distributed to CXC scientists via HTML interface.

  11. Monitoring game-based motor rehabilitation of patients at home for better plans of care and quality of life.

    PubMed

    Ponte, S; Gabrielli, S; Jonsdottir, J; Morando, M; Dellepiane, S

    2015-01-01

    This paper describes the biomedical, remote monitoring infrastructure developed and currently tested in the EU REHAB@HOME project to support home rehabilitation of the upper extremity of persons post-stroke and in persons with other neurological disorders, such as Multiple Sclerosis patients, in order to track their progress over therapy and improve their Quality of Life. The paper will specifically focus on describing the initial testing of the tele-rehabilitation system's components for patients' biomedical monitoring over therapy, which support the delivery and monitoring of more personalized, engaging plans of care by rehabilitation centers and services.

  12. Shared performance monitor in a multiprocessor system

    DOEpatents

    Chiu, George; Gara, Alan G; Salapura, Valentina

    2014-12-02

    A performance monitoring unit (PMU) and method for monitoring performance of events occurring in a multiprocessor system. The multiprocessor system comprises a plurality of processor devices units, each processor device for generating signals representing occurrences of events in the processor device, and, a single shared counter resource for performance monitoring. The performance monitor unit is shared by all processor cores in the multiprocessor system. The PMU is further programmed to monitor event signals issued from non-processor devices.

  13. Online information system for data collection of cattle quality

    NASA Astrophysics Data System (ADS)

    Sugiharti, E.; Arifudin, R.; Putra, A. T.

    2018-03-01

    Innovation and development of the science and technology which proclaimed by the government through Ristekdikti need to be supported. On the other hand, the Department of Animal Husbandry and Fisheries began introducing the Cattle Card system that contains the identity of each farm animal. Therefore, UNNES especially the Department of Computer Science of FMIPA UNNES, need to give positive contribution in the field of Science and Technology to support the manual system of Cattle Card, through the preparation of prototype of the online information system of data collection of cattle in Semarang regency. The main problem is how to monitor the data of cattle quality through online information system in Semarang regency? The purpose of this research is to produce the prototype of an online information system for data collection of cattle quality in Semarang regency. Main activities: (1) Prepare the flowchart of an online system for data collection of cattle quality. (2) Collecting data to obtain data on identity descriptions of each cattle, owners, mutation records, and health records of livestock cattle. (3) Creation of the prototype of an online information system for data collection of cattle quality in Semarang Regency. The results, (1) had been produced the prototype of an online information system for data collection of cattle in the region of Semarang regency. (2) Socialization of the online information system for cattle quality data collection and exploring input from various related stakeholders. (3) There had been a limited trial of prototypes of the system in Pabelan district in the working area of the Department of Animal Husbandry and Fisheries of Semarang regency and succeeded well.

  14. Monitoring and Assessment of Youshui River Water Quality in Youyang

    NASA Astrophysics Data System (ADS)

    Wang, Xue-qin; Wen, Juan; Chen, Ping-hua; Liu, Na-na

    2018-02-01

    By monitoring the water quality of Youshui River from January 2016 to December 2016, according to the indicator grading and the assessment standard of water quality, the formulas for 3 types water quality indexes are established. These 3 types water quality indexes, the single indicator index Ai, single moment index Ak and the comprehensive water quality index A, were used to quantitatively evaluate the quality of single indicator, the water quality and the change of water quality with time. The results show that, both total phosphorus and fecal coliform indicators exceeded the standard, while the other 16 indicators measured up to the standard. The water quality index of Youshui River is 0.93 and the grade of water quality comprehensive assessment is level 2, which indicated that the water quality of Youshui River is good, and there is room for further improvement. To this end, several protection measures for Youshui River environmental management and pollution treatment are proposed.

  15. On predicting monitoring system effectiveness

    NASA Astrophysics Data System (ADS)

    Cappello, Carlo; Sigurdardottir, Dorotea; Glisic, Branko; Zonta, Daniele; Pozzi, Matteo

    2015-03-01

    While the objective of structural design is to achieve stability with an appropriate level of reliability, the design of systems for structural health monitoring is performed to identify a configuration that enables acquisition of data with an appropriate level of accuracy in order to understand the performance of a structure or its condition state. However, a rational standardized approach for monitoring system design is not fully available. Hence, when engineers design a monitoring system, their approach is often heuristic with performance evaluation based on experience, rather than on quantitative analysis. In this contribution, we propose a probabilistic model for the estimation of monitoring system effectiveness based on information available in prior condition, i.e. before acquiring empirical data. The presented model is developed considering the analogy between structural design and monitoring system design. We assume that the effectiveness can be evaluated based on the prediction of the posterior variance or covariance matrix of the state parameters, which we assume to be defined in a continuous space. Since the empirical measurements are not available in prior condition, the estimation of the posterior variance or covariance matrix is performed considering the measurements as a stochastic variable. Moreover, the model takes into account the effects of nuisance parameters, which are stochastic parameters that affect the observations but cannot be estimated using monitoring data. Finally, we present an application of the proposed model to a real structure. The results show how the model enables engineers to predict whether a sensor configuration satisfies the required performance.

  16. Comparison and cost analysis of drinking water quality monitoring requirements versus practice in seven developing countries.

    PubMed

    Crocker, Jonny; Bartram, Jamie

    2014-07-18

    Drinking water quality monitoring programs aim to support provision of safe drinking water by informing water quality management. Little evidence or guidance exists on best monitoring practices for low resource settings. Lack of financial, human, and technological resources reduce a country's ability to monitor water supply. Monitoring activities were characterized in Cambodia, Colombia, India (three states), Jordan, Peru, South Africa, and Uganda according to water sector responsibilities, monitoring approaches, and marginal cost. The seven study countries were selected to represent a range of low resource settings. The focus was on monitoring of microbiological parameters, such as E. coli, coliforms, and H2S-producing microorganisms. Data collection involved qualitative and quantitative methods. Across seven study countries, few distinct approaches to monitoring were observed, and in all but one country all monitoring relied on fixed laboratories for sample analysis. Compliance with monitoring requirements was highest for operational monitoring of large water supplies in urban areas. Sample transport and labor for sample collection and analysis together constitute approximately 75% of marginal costs, which exclude capital costs. There is potential for substantive optimization of monitoring programs by considering field-based testing and by fundamentally reconsidering monitoring approaches for non-piped supplies. This is the first study to look quantitatively at water quality monitoring practices in multiple developing countries.

  17. Performance Monitoring of Chilled-Water Distribution Systems Using HVAC-Cx

    PubMed Central

    Ferretti, Natascha Milesi; Galler, Michael A.; Bushby, Steven T.

    2017-01-01

    In this research we develop, test, and demonstrate the newest extension of the software HVAC-Cx (NIST and CSTB 2014), an automated commissioning tool for detecting common mechanical faults and control errors in chilled-water distribution systems (loops). The commissioning process can improve occupant comfort, ensure the persistence of correct system operation, and reduce energy consumption. Automated tools support the process by decreasing the time and the skill level required to carry out necessary quality assurance measures, and as a result they enable more thorough testing of building heating, ventilating, and air-conditioning (HVAC) systems. This paper describes the algorithm, developed by National Institute of Standards and Technology (NIST), to analyze chilled-water loops and presents the results of a passive monitoring investigation using field data obtained from BACnet® (ASHRAE 2016) controllers and presents field validation of the findings. The tool was successful in detecting faults in system operation in its first field implementation supporting the investigation phase through performance monitoring. Its findings led to a full energy retrocommissioning of the field site. PMID:29167584

  18. Performance Monitoring of Chilled-Water Distribution Systems Using HVAC-Cx.

    PubMed

    Ferretti, Natascha Milesi; Galler, Michael A; Bushby, Steven T

    2017-01-01

    In this research we develop, test, and demonstrate the newest extension of the software HVAC-Cx (NIST and CSTB 2014), an automated commissioning tool for detecting common mechanical faults and control errors in chilled-water distribution systems (loops). The commissioning process can improve occupant comfort, ensure the persistence of correct system operation, and reduce energy consumption. Automated tools support the process by decreasing the time and the skill level required to carry out necessary quality assurance measures, and as a result they enable more thorough testing of building heating, ventilating, and air-conditioning (HVAC) systems. This paper describes the algorithm, developed by National Institute of Standards and Technology (NIST), to analyze chilled-water loops and presents the results of a passive monitoring investigation using field data obtained from BACnet ® (ASHRAE 2016) controllers and presents field validation of the findings. The tool was successful in detecting faults in system operation in its first field implementation supporting the investigation phase through performance monitoring. Its findings led to a full energy retrocommissioning of the field site.

  19. A computerized system to monitor resilience indicators in organizations.

    PubMed

    de Carvalho, Paulo Victor Rodrigues; de Souza, Alan Pinheiro; Gomes, Jose Orlando

    2012-01-01

    The concepts developed by resilience engineering allow the understanding and monitoring the functioning of organizations and, particularly, to map the role of human activities, in success or in failure, enabling a better comprehension about how people make decisions in unexpected situations. The capture of information about human activities in the various organization levels gives managers a deeper real-time understanding of what is influencing the people performance, providing awareness of the factors that influence positively or negatively the organizational goals initially projected. The monitoring is important because the correct functioning of complex systems depends on the knowledge that people have to perform their activities and how the system environment provides tools that actually support the human performance. Therefore, organizations should look forward through precursors in operating signals to identify possible problems or solutions in the structure of tasks and activities, safety, quality, schedule, rework, and maintenance. We apply the concepts of resilience engineering to understand the organization by the analysis of cognitive tasks and activities. The aim is the development of a computerized system to monitor human activities to produce indicators to access system resilience. The validation of the approach was made in a real organization and the results show the successful applicability of the system. Based on findings obtained after the experiment of the system in a real organization, and managers and workers opinions, it was possible to show that the use of system provided an anticipated (real-time) perception about how activities are effectively being performed, allowing managers and workers to make decisions more consistent with daily problems, and also to anticipate solutions to cope with unexpected situations.

  20. Advances in recreational water quality monitoring at Indiana Dunes National Lakeshore

    USGS Publications Warehouse

    Smith, Wendy; Nevers, Meredith; Whitman, Richard L.

    2006-01-01

    Indiana Dunes has improved its ability to protect the health of swimmers through better science-based management and increased understanding of contaminants. Most research has focused on Escherichia coli and its nature, sources, and distribution because it is widely accepted as an indicator of potential pathogens. Though research on E. coli and recreational water quality is continually generating new information, public beach managers may gain valuable insight into this management issue from our experience at Indiana Dunes. This article reviews one of the longest maintained indicator bacteria monitoring programs in the National Park System, highlights lessons learned, and summarizes research findings that may be of interest to public beach managers.