Sample records for quality monitoring programs

  1. A ground-water-quality monitoring program for Nevada

    USGS Publications Warehouse

    Nowlin, Jon O.

    1986-01-01

    A program was designed for the systematic monitoring of ground-water quality in Nevada. Basic hydrologic and water-quality principles are discussed in the formulation of a rational approach to developing a statewide monitoring program. A review of ground-water monitoring efforts in Nevada through 1977 indicates that few requirements for an effective statewide program are being met. A suggested program has been developed that consists of five major elements: (1) A Background-Quality Network to assess the existing water quality in Nevada aquifers, (2) a Contamination Source Inventory of known or potential threats to ground-water quality, (3) Surveillance Networks to monitor ground-water quality in selected hydrographic areas, (4) Intensive Surveys of individual instances of known or potential ground-water contamination, and (5) Ground-Water Data File to manage data generated by the other monitoring elements. Two indices have been developed to help assign rational priorities for monitoring ground water in the 255 hydrographic areas of Nevada: (1) A Hydrographic-Area Priority Index for surveillance monitoring, and (2) A Development-Potential Index for background monitoring of areas with little or no current development. Requirements for efficient management of data from ground-water monitoring are discussed and the three major systems containing Nevada ground-water data are reviewed. More than 11,000 chemical analyses of ground water have been acquired from existing systems and incorporated into a prototype data base.

  2. Data-quality measures for stakeholder-implemented watershed-monitoring programs

    USGS Publications Warehouse

    Greve, Adrienne I.

    2002-01-01

    Community-based watershed groups, many of which collect environmental data, have steadily increased in number over the last decade. The data generated by these programs are often underutilized due to uncertainty in the quality of data produced. The incorporation of data-quality measures into stakeholder monitoring programs lends statistical validity to data. Data-quality measures are divided into three steps: quality assurance, quality control, and quality assessment. The quality-assurance step attempts to control sources of error that cannot be directly quantified. This step is part of the design phase of a monitoring program and includes clearly defined, quantifiable objectives, sampling sites that meet the objectives, standardized protocols for sample collection, and standardized laboratory methods. Quality control (QC) is the collection of samples to assess the magnitude of error in a data set due to sampling, processing, transport, and analysis. In order to design a QC sampling program, a series of issues needs to be considered: (1) potential sources of error, (2) the type of QC samples, (3) inference space, (4) the number of QC samples, and (5) the distribution of the QC samples. Quality assessment is the process of evaluating quality-assurance measures and analyzing the QC data in order to interpret the environmental data. Quality assessment has two parts: one that is conducted on an ongoing basis as the monitoring program is running, and one that is conducted during the analysis of environmental data. The discussion of the data-quality measures is followed by an example of their application to a monitoring program in the Big Thompson River watershed of northern Colorado.

  3. Framework for a ground-water quality monitoring and assessment program for California

    USGS Publications Warehouse

    Belitz, Kenneth; Dubrovsky, Neil M.; Burow, Karen; Jurgens, Bryant C.; John, Tyler

    2003-01-01

    The State of California uses more ground water than any other State in the Nation. With a population of over 30 million people, an agricultural economy based on intensive irrigation, large urban industrial areas, and naturally elevated concentrations of some trace elements, there is a wide range of contaminant sources that have the potential to contaminate ground water and limit its beneficial uses. In response to the many-and different-potential sources of ground-water contamination, the State of California has evolved an extensive set of rules and programs to protect ground-water quality, and agencies to implement the rules and programs. These programs have in common a focus on compliance with regulations governing chemical use and (or) ground-water quality. Although appropriate for, and successful at, their specific missions, these programs do not at present provide a comprehensive view of ground-water quality in the State of California. In October 2001, The California Assembly passed a bill, AB 599, establishing the Ground-Water- Quality Monitoring Act of 2001.' The goal of AB 599 is to improve Statewide comprehensive ground-water monitoring and increase availability of information about ground-water quality to the public. AB 599 requires the State Water Resources Control Board (SWRCB), in collaboration with an interagency task force (ITF) and a public advisory committee (PAC), to develop a plan for a comprehensive ground-water monitoring program. AB 599 specifies that the comprehensive program should be capable of assessing each ground-water basin in the State through direct and other statistically reliable sampling approaches, and that the program should integrate existing monitoring programs and design new program elements, as necessary. AB 599 also stresses the importance of prioritizing ground-water basins that provide drinking water. The United States Geological Survey (USGS), in cooperation with the SWRCB, and in coordination with the ITF and PAC, has

  4. DATA QUALITY OBJECTIVES-FOUNDATION OF A SUCCESSFUL MONITORING PROGRAM

    EPA Science Inventory

    The data quality objectives (DQO) process is a fundamental site characterization tool and the foundation of a successful monitoring program. The DQO process is a systematic planning approach based on the scientific method of inquiry. The process identifies the goals of data col...

  5. Comprehensive Monitoring Program: Air Quality Data Assessment Report for FY90. Volume 2. Version 3.1

    DTIC Science & Technology

    1991-09-01

    91311R01 If VERSION 3.10) VOLUME II Comm 2ND COPY COMPREHENSIVE MONITORING PROGRAM Contract Number DAAAI5-87-0095 AIR QUALITY DATA ASSESSMENT REPORT...MONITORING PROGRAM. FINAL AIR QUALITY DATA ASSESSMENT REPORT FOR FY90, VERSION 3.1 NONE 6. AUTHOR(S) 7. PERFORMING ORGANIZATION NAME(S) AND ADDRES.S(S) 8...RELEASE; DISTRIBUTION IS UNLIMITED 13. ABSTRACT (Maximum 200 words) THE OBJECTIVE OF THIS CMP IS TO: VERIFY AND EVALUATE POTENTIAL AIR QUALITY HEALTH

  6. Hampton roads regional Water-Quality Monitoring Program

    USGS Publications Warehouse

    Porter, Aaron J.; Jastram, John D.

    2016-12-02

    IntroductionHow much nitrogen, phosphorus, and suspended solids are contributed by the highly urbanized areas of the Hampton Roads region in Virginia to Chesapeake Bay? The answer to this complex question has major implications for policy decisions, resource allocations, and efforts aimed at restoring clean waters to Chesapeake Bay and its tributaries. To quantify the amount of nitrogen, phosphorus, and suspended solids delivered to the bay from this region, the U.S. Geological Survey has partnered with the Hampton Roads Sanitation District (HRSD), in cooperation with the Hampton Roads Planning District Commission (HRPDC), to conduct a water-quality monitoring program throughout the Hampton Roads region.

  7. Southern California Bight 2003 Regional Monitoring Program: V. water quality

    USGS Publications Warehouse

    Nezlin, Nikolay P.; DiGiacomo, Paul M.; Weisberg, Stephen B.; Diehl, Dario W.; Warrick, Jonathan A.; Mengel, Michael J.; Jones, Burton H.; Reifel, Kristen M.; Johnson, Scott C.; Ohlmann, J. Carter; Washburn, Libe; Terrill, Eric J.

    2007-01-01

    More than $30 million is expended annually on environmental monitoring in the Southern California Bight (SCB), yet only 5% of the Bight is monitored on an ongoing basis. Therefore, environmental managers in the SCB decided to expand their monitoring program and, starting in 1994, decided to conduct periodic regional assessments of ecosystem condition and assess the overall health of the SCB. Sixty-five different organizations collaborated in 2003 to create the third SCB Regional Monitoring Program (Bight '03). Bight '03 was designed to be integrated regional monitoring program that encompasses regulatory, academic, and non-governmental agencies. Bight '03 had three components: Coastal Ecology, Shoreline Microbiology, and Water Quality. This report addresses the purpose, approach, findings, and recommendations from the Water Quality component, which focused on contamination-laden stormwater runoff, in particularly its variability in time and space as well as its short-term ecological impacts. Specifically, the Bight '03 Water Quality component had three primary goals, the first of which was to described the temporal evolution of stormwater plumes produced by the major southern California rivers. Specifically, the study was intended to determine how far offshore the plumes extended, how rapidly they advected, how long before the plumes dispersed and how these properties differed among storms and river systems. The second goal was to describe how the physical properties (e.g., turbidity, temperature, salinity) of the plume related to biogeochemical and ecological properties that are of more direct concern to the water quality management community. Accomplished primarily through ship-based sampling of water quality parameters, this second goal was to describe how far offshore, and for how ;long after the storm, elevated bacterial concentrations, toxicity, and nutrients could be detected. Similar to the fist goal, the study also addressed how these answers differed

  8. Microbiological monitoring for the US Geological Survey National Water-Quality Assessment Program

    USGS Publications Warehouse

    Francy, Donna S.; Myers, Donna N.; Helsel, Dennis R.

    2000-01-01

    Data to characterize the microbiological quality of the Nation?s fresh, marine, and estuarine waters are usually collected for local purposes, most often to judge compliance with standards for protection of public health in swimmable or drinkable waters. Methods and procedures vary with the objectives and practices of the parties collecting data and are continuously being developed or modified. Therefore, it is difficult to provide a nationally consistent picture of the microbial quality of the Nation?s waters. Study objectives and guidelines for a national microbiological monitoring program are outlined in this report, using the framework of the U.S. Geological Survey (USGS) National Water-Quality Assessment (NAWQA) program. A national program is designed to provide long-term data on the presence of microbiological pathogens and indicators in ground water and surface water to support effective water policy and management. Three major groups of waterborne pathogens affect the public health acceptability of waters in the United States?bacteria, protozoa, and viruses. Microbiological monitoring in NAWQA would be designed to assess the occurrence, distribution, and trends of pathogenic organisms and indicators in surface waters and ground waters; relate the patterns discerned to factors that help explain them; and improve our understanding of the processes that control microbiological water quality.

  9. Groundwater-quality monitoring program in Chester County, Pennsylvania, 1980-2008

    USGS Publications Warehouse

    Senior, Lisa A.; Sloto, Ronald A.

    2010-01-01

    The U.S. Geological Survey in cooperation with the Chester County Water Resources Authority and the Chester County Health Department began a groundwater-quality monitoring program in 1980 in Chester County, Pa., where a large percentage of the population relies on wells for drinking-water supply. This report documents the program and serves as a reference for data collected through the program from 1980 through 2008. The initial focus of the program was to collect data on groundwater quality near suspected localized sources of contamination, such as uncontrolled landfills and suspected industrial wastes, to determine if contaminants were present that might pose a health risk to those using the groundwater. Subsequently, the program was expanded to address the effects of widely distributed contaminant sources associated with agricultural and residential land uses on groundwater quality and to document naturally occurring constituents, such as radium, radon, and arsenic, that are potential hazards in drinking water. Since 2000, base-flow stream samples have been collected in addition to well-water and spring samples in a few small drainage areas to investigate the relation between groundwater quality measured in well samples and streams. The program has primarily consisted of spatial assessment with limited temporal data collected on groundwater quality. Most data were collected through the monitoring program for reconnaissance purposes to identify and locate groundwater-quality problems and generally were not intended for rigorous statistical analyses that might determine land-use or geochemical factors affecting groundwater quality in space or through time. Results of the program found several contaminants associated with various land uses and human activities in groundwater in Chester County. Volatile organic compounds (such as trichloroethylene) were measured in groundwater near suspected localized contaminant sources in concentrations that exceeded drinking

  10. Lessons from a 5 yr citizen-science monitoring program, Mountain Watch, to engage hikers in air quality/visibility and plant phenology monitoring in the mountains

    NASA Astrophysics Data System (ADS)

    Murray, G.; Weihrauch, D.; Kimball, K.; McDonough, C.

    2010-12-01

    The AMC’s citizen scientist monitoring program, Mountain Watch, engages hikers in observational monitoring while recreating in the northern Appalachian Mountains. The program uses two monitoring activities:1) tracking the phenology of 11 mountain flowers species, and 2) the visitors real world perception of on-mountain visibility and its ‘quality’ with proximate monitored air quality parameters. The Mountain Watch program objectives are a) to engage and educate the public through hands-on monitoring, b) to motivate the participant to take further action towards environmental stewardship, and c) to provide supplemental data to AMC’s ongoing science-based research to further our understanding of the impact of human activity on mountain ecosystems. The Mountain Watch plant monitoring includes recording the time and location of alpine and forest plants flowering and other phenological phases using AMC field guides and datasheets. In the White Mountains of New Hampshire concurrent meteorological data, including soil temperature, is paired with the phenology observations as part of AMC’s research to develop spatial and temporal phenology models with air and soil temperature for northeastern mountains. Mountain Watch’s visibility monitoring program has hikers record visual range and rate the view at select vistas in comparison to a clear day view photo guide when visiting AMC’s backcountry huts. The results are compared to proximate air quality measurements, which assists in determining how White Mountain National Forest air quality related values and natural resources management objectives are being met. Since 2006 the Mountain Watch program has received over 3,500 citizen datasheets for plant reproductive phenology and visibility monitoring. We estimate that we have reached more than 15,000 hikers through our facility based education programming focused on air quality and phenology and field monitoring hikes. While we consider this good success in engaging

  11. A Two-Year Water Quality Monitoring Curriculum.

    ERIC Educational Resources Information Center

    Glazer, Richard B.; And Others

    The Environmental Protection Agency developed this curriculum to train technicians to monitor water quality. Graduates of the program should be able to monitor municipal, industrial, and commercial discharges; test drinking water for purity; and determine quality of aquatic environments. The program includes algebra, communication skills, biology,…

  12. Loch Vale Watershed Long-Term Ecological Research and Monitoring Program: Quality Assurance Report, 2003-09

    USGS Publications Warehouse

    Richer, Eric E.; Baron, Jill S.

    2011-01-01

    The Loch Vale watershed project is a long-term research and monitoring program located in Rocky Mountain National Park that addresses watershed-scale ecosystem processes, particularly as they respond to atmospheric deposition and climate variability. Measurements of precipitation depth, precipitation chemistry, discharge, and surface-water quality are made within the watershed and elsewhere in Rocky Mountain National Park. As data collected for the program are used by resource managers, scientists, policy makers, and students, it is important that all data collected in Loch Vale watershed meet high standards of quality. In this report, data quality was evaluated for precipitation, discharge, and surface-water chemistry measurements collected during 2003-09. Equipment upgrades were made at the Loch Vale National Atmospheric Deposition Program monitoring site to improve precipitation measurements and evaluate variability in precipitation depth and chemistry. Additional solar panels and batteries have been installed to improve the power supply, and data completeness, at the NADP site. As a result of equipment malfunction, discharge data for the Loch Outlet were estimated from October 18, 2005, to August 17, 2006. Quality-assurance results indicate that more than 98 percent of all surface-water chemistry measurements were accurate and precise. Records that did not meet quality criteria were removed from the database. Measurements of precipitation depth, precipitation chemistry, discharge, and surface-water quality were all sufficiently complete and consistent to support project data needs.

  13. Video Monitoring a Simulation-Based Quality Improvement Program in Bihar, India.

    PubMed

    Dyer, Jessica; Spindler, Hilary; Christmas, Amelia; Shah, Malay Bharat; Morgan, Melissa; Cohen, Susanna R; Sterne, Jason; Mahapatra, Tanmay; Walker, Dilys

    2018-04-01

    Simulation-based training has become an accepted clinical training andragogy in high-resource settings with its use increasing in low-resource settings. Video recordings of simulated scenarios are commonly used by facilitators. Beyond using the videos during debrief sessions, researchers can also analyze the simulation videos to quantify technical and nontechnical skills during simulated scenarios over time. Little is known about the feasibility and use of large-scale systems to video record and analyze simulation and debriefing data for monitoring and evaluation in low-resource settings. This manuscript describes the process of designing and implementing a large-scale video monitoring system. Mentees and Mentors were consented and all simulations and debriefs conducted at 320 Primary Health Centers (PHCs) were video recorded. The system design, number of video recordings, and inter-rater reliability of the coded videos were assessed. The final dataset included a total of 11,278 videos. Overall, a total of 2,124 simulation videos were coded and 183 (12%) were blindly double-coded. For the double-coded sample, the average inter-rater reliability (IRR) scores were 80% for nontechnical skills, and 94% for clinical technical skills. Among 4,450 long debrief videos received, 216 were selected for coding and all were double-coded. Data quality of simulation videos was found to be very good in terms of recorded instances of "unable to see" and "unable to hear" in Phases 1 and 2. This study demonstrates that video monitoring systems can be effectively implemented at scale in resource limited settings. Further, video monitoring systems can play several vital roles within program implementation, including monitoring and evaluation, provision of actionable feedback to program implementers, and assurance of program fidelity.

  14. 40 CFR 130.4 - Water quality monitoring.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 22 2014-07-01 2013-07-01 true Water quality monitoring. 130.4 Section 130.4 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS WATER QUALITY PLANNING AND MANAGEMENT § 130.4 Water quality monitoring. (a) In accordance with section 106(e)(1...

  15. 40 CFR 130.4 - Water quality monitoring.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 23 2012-07-01 2012-07-01 false Water quality monitoring. 130.4 Section 130.4 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS WATER QUALITY PLANNING AND MANAGEMENT § 130.4 Water quality monitoring. (a) In accordance with section 106(e)(1...

  16. 40 CFR 130.4 - Water quality monitoring.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 23 2013-07-01 2013-07-01 false Water quality monitoring. 130.4 Section 130.4 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS WATER QUALITY PLANNING AND MANAGEMENT § 130.4 Water quality monitoring. (a) In accordance with section 106(e)(1...

  17. Analysis of Water-Quality Trends for Selected Streams in the Water Chemistry Monitoring Program, Michigan, 1998-2005

    USGS Publications Warehouse

    Hoard, C.J.; Fuller, Lori M.; Fogarty, Lisa R.

    2009-01-01

    In 1998, the Michigan Department of Environmental Quality and the U.S. Geological Survey began a long-term monitoring program to evaluate the water quality of most watersheds in Michigan. Major goals of this Water-Chemistry Monitoring Program were to identify streams exceeding or not meeting State or Federal water-quality standards and to assess if constituent concentrations reflecting water quality in these streams were increasing or decreasing over time. As part of this program, water-quality data collected from 1998 to 2005 were analyzed to identify potential trends. Sixteen water-quality constituents were analyzed at 31 sites across Michigan, 28 of which had sufficient data to analyze for trends. Trend analysis on the various water-quality data was done using the uncensored Seasonal Kendall test within the computer program ESTREND. The most prevalent trend detected throughout the state was for chloride. Chloride trends were detected at 8 of the 28 sites; trends at 7 sites were increasing and the trend at 1 site was decreasing. Although no trends were detected for various nitrogen species or phosphorus, these constituents were detected at levels greater than the U.S. Environmental Protection Agency recommendations for nutrients in water. The results of the trend analysis will help to establish a baseline to evaluate future changes in water quality in Michigan streams.

  18. Air quality monitor and acid rain networks

    NASA Technical Reports Server (NTRS)

    Rudolph, H.

    1980-01-01

    The air quality monitor program which consists of two permanent air monitor stations (PAMS's) and four mobile shuttle pollutant air monitor stations (SPAMS's) is evaluated. The PAMS measures SO sub X, NO sub X particulates, CO, O3, and nonmethane hydrocarbons. The SPAMS measures O3, SO2, HCl, and particulates. The collection and analysis of data in the rain monitor program are discussed.

  19. 40 CFR 51.190 - Ambient air quality monitoring requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Ambient air quality monitoring... PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Ambient Air Quality Surveillance § 51.190 Ambient air quality monitoring requirements. The requirements for monitoring ambient air...

  20. 40 CFR 51.190 - Ambient air quality monitoring requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 2 2013-07-01 2013-07-01 false Ambient air quality monitoring... PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Ambient Air Quality Surveillance § 51.190 Ambient air quality monitoring requirements. The requirements for monitoring ambient air...

  1. 40 CFR 51.190 - Ambient air quality monitoring requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 2 2014-07-01 2014-07-01 false Ambient air quality monitoring... PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Ambient Air Quality Surveillance § 51.190 Ambient air quality monitoring requirements. The requirements for monitoring ambient air...

  2. 40 CFR 51.190 - Ambient air quality monitoring requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 2 2011-07-01 2011-07-01 false Ambient air quality monitoring... PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Ambient Air Quality Surveillance § 51.190 Ambient air quality monitoring requirements. The requirements for monitoring ambient air...

  3. 40 CFR 51.190 - Ambient air quality monitoring requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 2 2012-07-01 2012-07-01 false Ambient air quality monitoring... PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Ambient Air Quality Surveillance § 51.190 Ambient air quality monitoring requirements. The requirements for monitoring ambient air...

  4. Quality assurance program plan for radionuclide airborne emissions monitoring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boom, R.J.

    1995-12-01

    This Quality Assurance Program Plan identifies quality assurance program requirements and addresses the various Westinghouse Hanford Company organizations and their particular responsibilities in regards to sample and data handling of radiological airborne emissions. This Quality Assurance Program Plan is prepared in accordance with and to written requirements.

  5. Protocols for collection of streamflow, water-quality, streambed-sediment, periphyton, macroinvertebrate, fish, and habitat data to describe stream quality for the Hydrobiological Monitoring Program, Equus Beds Aquifer Storage and Recovery Program, city of Wichita, Kansas

    USGS Publications Warehouse

    Stone, Mandy L.; Rasmussen, Teresa J.; Bennett, Trudy J.; Poulton, Barry C.; Ziegler, Andrew C.

    2012-01-01

    The city of Wichita, Kansas uses the Equus Beds aquifer, one of two sources, for municipal water supply. To meet future water needs, plans for artificial recharge of the aquifer have been implemented in several phases. Phase I of the Equus Beds Aquifer Storage and Recovery (ASR) Program began with injection of water from the Little Arkansas River into the aquifer for storage and subsequent recovery in 2006. Construction of a river intake structure and surface-water treatment plant began as implementation of Phase II of the Equus Beds ASR Program in 2010. An important aspect of the ASR Program is the monitoring of water quality and the effects of recharge activities on stream conditions. Physical, chemical, and biological data provide the basis for an integrated assessment of stream quality. This report describes protocols for collecting streamflow, water-quality, streambed-sediment, periphyton, macroinvertebrate, fish, and habitat data as part of the city of Wichita's hydrobiological monitoring program (HBMP). Following consistent and reliable methods for data collection and processing is imperative for the long-term success of the monitoring program.

  6. Data Quality Objectives Supporting the Environmental Soil Monitoring Program for the Idaho National Laboratory Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haney, Thomas Jay

    This document describes the process used to develop data quality objectives for the Idaho National Laboratory (INL) Environmental Soil Monitoring Program in accordance with U.S. Environmental Protection Agency guidance. This document also develops and presents the logic that was used to determine the specific number of soil monitoring locations at the INL Site, at locations bordering the INL Site, and at locations in the surrounding regional area. The monitoring location logic follows the guidance from the U.S. Department of Energy for environmental surveillance of its facilities.

  7. Idaho's surface-water-quality monitoring program: results from five sites sampled during water years 1990-93

    USGS Publications Warehouse

    ,

    1994-01-01

    In 1990, the U.S. Geological Survey (USGS), in cooperation with the Idaho Department of Health and Welfare, Division of Environmental Quality, implemented a statewide water-quality monitoring program in response to Idaho's antidegradation policy as required by the Clean Water Act. The program objective is to provide water-quality managers with a coordinated statewide network to detect trends in surface-water quality. The monitoring program includes the collection and analysis of samples from 56 sites on the Bear, Clearwater, Kootenai, Pend Oreille, Salmon, Snake, and Spokane Rivers and their tributaries (fig. 1). Samples are collected every year at 5 sites (annual sites) in drainage basins where long-term water-quality management is practiced, every other year at 19 sites (biennial sites) in basins where land and water uses change slowly, and every third year at 32 sites (triennial sites) where future development may affect water quality. Each year, 25 of the 56 sites are sampled. This report discusses results of sampling at five annual sites. During water years 1990-93 (October 1, 1989, through September 30, 1993), samples were collected six times per year at the five annual sites (fig. 1). Onsite analyses were made for discharge, specific conductance, pH, temperature, dissolved oxygen, bacteria (fecal coliform and fecal streptococci), and alkalinity. Laboratory analyses were made for major ions, nutrients, trace elements, and suspended sediment. Suspended sediment, nitrate, fecal coliform, trace elements, and specific conductance were used to characterize surface-water quality. Because concentrations of all trace elements except zinc were near detection limits, only zinc is discussed.

  8. Statistical analysis of the water-quality monitoring program, Upper Klamath Lake, Oregon, and optimization of the program for 2013 and beyond

    USGS Publications Warehouse

    Eldridge, Sara L. Caldwell; Wherry, Susan A.; Wood, Tamara M.

    2014-01-01

    Upper Klamath Lake in south-central Oregon has become increasingly eutrophic over the past century and now experiences seasonal cyanobacteria-dominated and potentially toxic phytoplankton blooms. Growth and decline of these blooms create poor water-quality conditions that can be detrimental to fish, including two resident endangered sucker species. Upper Klamath Lake is the primary water supply to agricultural areas within the upper Klamath Basin. Water from the lake is also used to generate power and to enhance and sustain downstream flows in the Klamath River. Water quality in Upper Klamath Lake has been monitored by the Klamath Tribes since the early 1990s and by the U.S. Geological Survey (USGS) since 2002. Management agencies and other stakeholders have determined that a re-evaluation of the goals for water-quality monitoring is warranted to assess whether current data-collection activities will continue to adequately provide data for researchers to address questions of interest and to facilitate future natural resource management decisions. The purpose of this study was to (1) compile an updated list of the goals and objectives for long-term water-quality monitoring in Upper Klamath Lake with input from upper Klamath Basin stakeholders, (2) assess the current water-quality monitoring programs in Upper Klamath Lake to determine whether existing data-collection strategies can fulfill the updated goals and objectives for monitoring, and (3) identify potential modifications to future monitoring plans in accordance with the updated monitoring objectives and improve stakeholder cooperation and data-collection efficiency. Data collected by the Klamath Tribes and the USGS were evaluated to determine whether consistent long-term trends in water-quality variables can be described by the dataset and whether the number and distribution of currently monitored sites captures the full range of environmental conditions and the multi-scale variability of water-quality

  9. Multidate Landsat lake quality monitoring program

    NASA Technical Reports Server (NTRS)

    Fisher, L. T.; Scarpace, F. L.; Thomsen, R. G.

    1979-01-01

    A unified package of files and programs has been developed to automate the multidate Landsat-derived analyses of water quality for about 3000 inland lakes throughout Wisconsin. A master lakes file which stores geographic information on the lakes, a file giving the latitudes and longitudes of control points for scene navigation, and a program to estimate control point locations and produce microfiche character maps for scene navigation are among the files and programs of the system. The use of ground coordinate systems to isolate irregular shaped areas which can be accessed at will appears to provide an economical means of restricting the size of the data set.

  10. [Impact of a quality assurance program on the use of neuromuscular monitoring and reversal of muscle relaxants].

    PubMed

    Motamed, C; Bourgain, J-L

    2009-04-01

    As part of a quality assurance in the anaesthesia department, this study was designed to enhance the rate of neuromuscular blockade monitoring for patients receiving muscle relaxant during anaesthesia. After approval of our local ethical committee, we assessed 200 computerized anaesthesia records in which neuromuscular relaxants were used. The following data were collected: demographic characteristics, durations of anaesthesia and surgery, use of neuromuscular monitoring, reversal agents and the quality of neuromuscular monitoring. The results were discussed with all anaesthesia providers of the department and an internal guideline was elaborated with the endpoint that all patients having muscle relaxants should have quantitative neuromuscular monitoring. Six months later, another assessment of 200 consecutive records collected the same data to check the efficiency of the elaborated guideline. The monitoring rate was of 67% at the first assessment and increased to 94% (p<0.05). The reversal rate was at 48% in the first assessment and was stable at the second assessment (50%). The rate of patients not monitored and not reversed decreased from 5 to 2% (p<0.05). This study shows that as part of a quality assurance program systematic quantitative monitoring of neuromuscular blockade can be significantly increased.

  11. LOVE CANAL MONITORING PROGRAM. GCA QA/QC (QUALITY ASSURANCE/QUALITY CONTROL) SUMMARY REPORT

    EPA Science Inventory

    One of the most important responsibilities of the Love Canal prime contractor was the institution and maintenance of a quality assurance program. An important objective of the quality assurance program was to alert the subcontractors to the importance of high quality work on thei...

  12. Wyoming groundwater-quality monitoring network

    USGS Publications Warehouse

    Boughton, Gregory K.

    2011-01-01

    A wide variety of human activities have the potential to contaminate groundwater. In addition, naturally occurring constituents can limit the suitability of groundwater for some uses. The State of Wyoming has established rules and programs to evaluate and protect groundwater quality based on identified uses. The Wyoming Groundwater-Quality Monitoring Network (WGQMN) is a cooperative program between the U.S. Geological Survey (USGS) and the Wyoming Department of Environmental Quality (WDEQ) and was implemented in 2009 to evaluate the water-quality characteristics of the State's groundwater. Representatives from USGS, WDEQ, U.S. Environmental Protection Agency (USEPA), Wyoming Water Development Office, and Wyoming State Engineer's Office formed a steering committee, which meets periodically to evaluate progress and consider modifications to strengthen program objectives. The purpose of this fact sheet is to describe the WGQMN design and objectives, field procedures, and water-quality analyses. USGS groundwater activities in the Greater Green River Basin also are described.

  13. Analytical approaches to quality assurance and quality control in rangeland monitoring data

    USDA-ARS?s Scientific Manuscript database

    Producing quality data to support land management decisions is the goal of every rangeland monitoring program. However, the results of quality assurance (QA) and quality control (QC) efforts to improve data quality are rarely reported. The purpose of QA and QC is to prevent and describe non-sampling...

  14. Optimizing an estuarine water quality monitoring program through an entropy-based hierarchical spatiotemporal Bayesian framework

    NASA Astrophysics Data System (ADS)

    Alameddine, Ibrahim; Karmakar, Subhankar; Qian, Song S.; Paerl, Hans W.; Reckhow, Kenneth H.

    2013-10-01

    The total maximum daily load program aims to monitor more than 40,000 standard violations in around 20,000 impaired water bodies across the United States. Given resource limitations, future monitoring efforts have to be hedged against the uncertainties in the monitored system, while taking into account existing knowledge. In that respect, we have developed a hierarchical spatiotemporal Bayesian model that can be used to optimize an existing monitoring network by retaining stations that provide the maximum amount of information, while identifying locations that would benefit from the addition of new stations. The model assumes the water quality parameters are adequately described by a joint matrix normal distribution. The adopted approach allows for a reduction in redundancies, while emphasizing information richness rather than data richness. The developed approach incorporates the concept of entropy to account for the associated uncertainties. Three different entropy-based criteria are adopted: total system entropy, chlorophyll-a standard violation entropy, and dissolved oxygen standard violation entropy. A multiple attribute decision making framework is adopted to integrate the competing design criteria and to generate a single optimal design. The approach is implemented on the water quality monitoring system of the Neuse River Estuary in North Carolina, USA. The model results indicate that the high priority monitoring areas identified by the total system entropy and the dissolved oxygen violation entropy criteria are largely coincident. The monitoring design based on the chlorophyll-a standard violation entropy proved to be less informative, given the low probabilities of violating the water quality standard in the estuary.

  15. Effects of an Asthma Training and Monitoring Program on Children’s Disease Management and Quality of Life

    PubMed Central

    Ekici, Behice; Cimete, Güler

    2015-01-01

    OBJECTIVES To determine the effects of an asthma training and monitoring program on children’s disease management and quality of life. MATERIAL AND METHODS The sample consisted of 120 children and their parents. Data were collected during, at the beginning, and at the end of the 3-month monitoring period using four forms and a quality of life scale. After an initial evaluation, approaches to control symptoms and asthma triggers and measures that might be taken for them were taught to the children and parents. The children recorded the conditions of trigger exposure, experience of disease symptoms, their effects on daily activities, and therapeutic implementations on a daily basis. RESULTS During the 3-month monitoring period, the number of days when the children were exposed to triggers (p=0.000) and experienced disease symptoms decreased to a statistically significant level (p=0.006). Majority of domestic triggers disappeared, but those stemming from the structure of the house and non-domestic triggers indicated no change (p>0.05). Moreover, 30.8% of the children applied to a physician/hospital/emergency service, 4.2% of the children were hospitalized, and 30% of them could not go to school. The number of times when the children applied to a physician/hospital/emergency (p=0.013), the number of times they used medicines (p=0.050), and the number of days they could not go to school (p=0.002) decreased at a statistically significant level, and their quality of life increased (p=0.001). CONCLUSION Asthma training and monitoring program decreased children’s rate of experiencing asthma symptoms and implementations of therapeutic purposes and increased their life quality. PMID:29404097

  16. Quality Indicators of Online Programs

    ERIC Educational Resources Information Center

    Hirner, Leo; Kochtanek, Thomas

    2012-01-01

    The continued growth of online programs in higher education has resulted in concerns about how institutions monitor the quality of their online programs. These concerns indicate a need for a process by which online programs may be evaluated and compared. They provided the impetus for this study, the goals of which were to identify quality…

  17. Preliminary assessment of a water-quality monitoring program for total maximum daily loads in Johnson County, Kansas, January 2015 through June 2016

    USGS Publications Warehouse

    Rasmussen, Teresa J.; Paxson, Chelsea R.

    2017-08-25

    Municipalities in Johnson County in northeastern Kansas are required to implement stormwater management programs to reduce pollutant discharges, protect water quality, and comply with applicable water-quality regulations in accordance with National Pollutant Discharge Elimination System permits for stormwater discharge. To this end, municipalities collect grab samples at streams entering and leaving their jurisdiction to determine levels of excessive nutrients, sediment, and fecal bacteria to characterize pollutants and understand the factors affecting them.In 2014, the U.S. Geological Survey and the Johnson County Stormwater Management Program, with input from the Kansas Department of Health and Environment, initiated a 5-year monitoring program to satisfy minimum sampling requirements for each municipality as described by new stormwater permits issued to Johnson County municipalities. The purpose of this report is to provide a preliminary assessment of the monitoring program. The monitoring program is described, a preliminary assessment of the monitoring program design is provided using water-quality data collected during the first 2 years of the program, and the ability of the current monitoring network and sampling plan to provide data sufficient to quantify improvements in water quality resulting from implemented and planned best management practices is evaluated. The information in this initial report may be used to evaluate changes in data collection methods while data collection is still ongoing that may lead to improved data utility.Discrete water-quality samples were collected at 27 sites and analyzed for nutrients, Escherichia coli (E. coli) bacteria, total suspended solids, and suspended-sediment concentration. In addition, continuous water-quality data (water temperature, pH, dissolved oxygen, specific conductance, turbidity, and nitrate plus nitrite) were collected at one site to characterize variability and provide a basis for comparison to discrete

  18. The Savannah River Site's Groundwater Monitoring Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This report summarizes the Savannah River Site (SRS) groundwater monitoring program conducted during the first quarter of 1992. It includes the analytical data, field data, data review, quality control, and other documentation for this program; provides a record of the program's activities; and serves as an official document of the analytical results.

  19. Satellite global monitoring of environmental quality

    NASA Technical Reports Server (NTRS)

    Schiffer, R. A.

    1975-01-01

    The missions of two NASA satellites for the monitoring of environmental quality are described: Nimbus G, the Air Pollution and Oceanographic Observing Satellite, and the Applications Explorer Mission (AEM) satellite to be used in the Stratospheric Aerosol and Gas Experiment (SAGE). The scientific payload of Nimbus G is described in detail with a discussion of limb infrared monitoring of the stratosphere, the stratospheric and mesospheric sounder, stratospheric aerosol measurement, the solar and backscatter UV spectrometer for ozone mapping, the earth radiation budget experiment, the scanning multichannel microwave radiometer, the coastal zone color scanner and the temperature-humidity infrared radiometer. A brief description is given of the SAGE program and future NASA plans relating to the global monitoring of environmental quality are outlined.

  20. The strategy for improving water-quality monitoring in the United States; final report of the Intergovernmental Task Force on Monitoring Water Quality; technical appendices

    USGS Publications Warehouse

    ,

    1995-01-01

    The Intergovernmental Task Force on Monitoring Water Quality (ITFM) prepared this report in collaboration with representatives of all levels of government and the private sector. The report recommends a strategy for nationwide water-quality monitoring and technical monitoring improvements to support sound water-quality decisionmaking. The strategy is intended to achieve a better return on public and private investments in monitoring, environmental protection, and natural resources management. It is also designed to expand the base of information useful to a variety of users at multiple geographic scales. Institutional and technical changes are needed to improve water-quality monitoring and to meet the full range of monitoring requirements. Monitoring must be incorporated as a critical element of program planning, implementation, and evaluation. The strategy includes recommendations in many key elements, such as the development of goal-oriented monitoring and indicators, institutional collaboration, and methods comparability. Initial actions have been taken to implement the strategy. Several Federal agencies have jointly purchased and shared remotely sensed land-cover information needed for water assessment. Major agency data systems are using common data-element names and reference tables that will ensure easy sharing of data. A number of States have held meetings with collectors of water information to initiate statewide monitoring strategies. New monitoring guidance has been developed for Federal water-quality grants to States. Many State offices have changed monitoring programs to place emphasis on priority watersheds and to improve assessment of water quality. As the competition increases for adequate supplies of clean water, concerns about public health and the environment escalate, and more demands are placed on the water information infrastructure. To meet these demands, the collaborative approach has already produced benefits, which will continue to grow as

  1. The Savannah River Site's groundwater monitoring program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This report summarizes the Savannah River Site (SRS) groundwater monitoring program conducted by EPD/EMS in the first quarter of 1991. In includes the analytical data, field data, data review, quality control, and other documentation for this program, provides a record of the program's activities and rationale, and serves as an official document of the analytical results.

  2. Monitoring Program Quality: Who and How Should It Be Done?

    ERIC Educational Resources Information Center

    Scholl, Geraldine T.; And Others

    Aspects of monitoring and evaluating programs for visually handicapped students are examined. The certification/accreditation program evaluation design is considered in terms of advantages and disadvantages. Roles of governmental (state and federal) and voluntary agencies are discussed. The functions of the National Accreditation Council of…

  3. The OA System of College - - Design of the Teaching Quality Monitoring Subsystem

    NASA Astrophysics Data System (ADS)

    Wu, Hongjuan; Ying, Hong; Jiang, Youyi; Yan, Pei

    According to the drawbacks of traditional teaching quality monitoring subsystems and based on the achievements of practical research in the teaching quality monitoring administration in College, this paper provides a design of overall structure of teaching quality monitoring subsystem, that is more suitable for colleges' management. This new system is endowed with the same features as .NET application programes: easy to extend, easy to maintain, flexible, convenient, and it let enterprises, students' parents and excellent graduates participate in teaching quality monitoring administration, have significant effect to ensure the quality of talent training in colleges.

  4. Improved quality monitoring of multi-center acupuncture clinical trials in China

    PubMed Central

    2009-01-01

    Background In 2007, the Chinese Science Division of the State Administration of Traditional Chinese Medicine(TCM) convened a special conference to discuss quality control for TCM clinical research. Control and assurance standards were established to guarantee the quality of clinical research. This paper provides practical guidelines for implementing strict and reproducible quality control for acupuncture randomized controlled trials (RCTs). Methods A standard quality control program (QCP) was established to monitor the quality of acupuncture trials. Case report forms were designed; qualified investigators, study personnel and data management personnel were trained. Monitors, who were directly appointed by the project leader, completed the quality control programs. They guaranteed data accuracy and prevented or detected protocol violations. Clinical centers and clinicians were audited, the randomization system of the centers was inspected, and the treatment processes were audited as well. In addition, the case report forms were reviewed for completeness and internal consistency, the eligibility and validity of the patients in the study was verified, and data was monitored for compliance and accuracy. Results and discussion The monitors complete their reports and submit it to quality assurance and the sponsors. Recommendations and suggestions are made for improving performance. By holding regular meetings to discuss improvements in monitoring standards, the monitors can improve quality and efficiency. Conclusions Supplementing and improving the existed guidelines for quality monitoring will ensure that large multi-centre acupuncture clinical trials will be considered as valid and scientifically stringent as pharmaceutical clinical trials. It will also develop academic excellence and further promote the international recognition of acupuncture. PMID:20035630

  5. Seven Q-Tracks monitors of laboratory quality drive general performance improvement: experience from the College of American Pathologists Q-Tracks program 1999-2011.

    PubMed

    Meier, Frederick A; Souers, Rhona J; Howanitz, Peter J; Tworek, Joseph A; Perrotta, Peter L; Nakhleh, Raouf E; Karcher, Donald S; Bashleben, Christine; Darcy, Teresa P; Schifman, Ron B; Jones, Bruce A

    2015-06-01

    Many production systems employ standardized statistical monitors that measure defect rates and cycle times, as indices of performance quality. Clinical laboratory testing, a system that produces test results, is amenable to such monitoring. To demonstrate patterns in clinical laboratory testing defect rates and cycle time using 7 College of American Pathologists Q-Tracks program monitors. Subscribers measured monthly rates of outpatient order-entry errors, identification band defects, and specimen rejections; median troponin order-to-report cycle times and rates of STAT test receipt-to-report turnaround time outliers; and critical values reporting event defects, and corrected reports. From these submissions Q-Tracks program staff produced quarterly and annual reports. These charted each subscriber's performance relative to other participating laboratories and aggregate and subgroup performance over time, dividing participants into best and median performers and performers with the most room to improve. Each monitor's patterns of change present percentile distributions of subscribers' performance in relation to monitoring durations and numbers of participating subscribers. Changes over time in defect frequencies and the cycle duration quantify effects on performance of monitor participation. All monitors showed significant decreases in defect rates as the 7 monitors ran variously for 6, 6, 7, 11, 12, 13, and 13 years. The most striking decreases occurred among performers who initially had the most room to improve and among subscribers who participated the longest. All 7 monitors registered significant improvement. Participation effects improved between 0.85% and 5.1% per quarter of participation. Using statistical quality measures, collecting data monthly, and receiving reports quarterly and yearly, subscribers to a comparative monitoring program documented significant decreases in defect rates and shortening of a cycle time for 6 to 13 years in all 7 ongoing

  6. Integrated Analysis Tools for the NERRS System-Wide Monitoring Program Data

    EPA Science Inventory

    Standardized monitoring programs have vastly improved the quantity and quality of data that form the basis of environmental decision-making. One example is the NOAA-funded National Estuarine Research Reserve System (NERRS) System-wide Monitoring Program (SWMP) that was implement...

  7. Some applications of remote sensing in atmospheric monitoring programs

    NASA Technical Reports Server (NTRS)

    Heller, A. N.; Bryson, J. C.; Vasuki, N. C.

    1972-01-01

    The applications of remote sensing in atmospheric monitoring programs are described. The organization, operations, and functions of an air quality monitoring network at New Castle County, Delaware is discussed. The data obtained by the air quality monitoring network ground stations and the equipment used to obtain atmospheric data are explained. It is concluded that correlation of the information obtained by the network will make it possible to anticipate air pollution problems in the Chesapeake Bay area before a crisis develops.

  8. Water-quality monitoring of Sweetwater Reservoir

    USGS Publications Warehouse

    Majewski, Michael

    2001-01-01

    Sweetwater Authority is concerned with the quality of water it provides to its customers. Results from the water-quality monitoring study that the USGS is conducting in the Sweetwater watershed show that the contaminant concentrations in bed sediments, water, and air are reflected in increased urbanization. The bed sediments show the most dramatic evidence of this impact with a sharp increase of persistent organic chemical concentrations over the past 65 years. Water quality is also affected by urbanization in the form of chemicals in the runoff water and deposition of airborne chemicals. The concentrations of the detected organic chemicals in Sweetwater and Loveland Reservoirs are all well below the guidance limits set by State and Federal agencies to protect human health. Many of these compounds are detected only because of the sensitive analytical methods used. This monitoring program provides the Sweetwater Authority with information on what monitored chemicals are present in the reservoirs, and at what concentrations. With this information, the Authority can assess the associated risks, and consider future water treatment and remediation. These results also help focus and support future efforts by Sweetwater Authority to protect the watershed.

  9. The National Water-Quality Assessment (NAWQA) Program planned monitoring and modeling activities for Texas, 2013–23

    USGS Publications Warehouse

    Ging, Patricia

    2013-01-01

    The U.S. Geological Survey’s (USGS) National Water-Quality Assessment (NAWQA) Program was established by Congress in 1992 to answer the following question: What is the status of the Nation’s water quality and is it getting better or worse? Since 1992, NAWQA has been a primary source of nationally consistent data and information on the quality of the Nation’s streams and groundwater. Data and information obtained from objective and nationally consistent water-quality monitoring and modeling activities provide answers to where, when, and why the Nation’s water quality is degraded and what can be done to improve and protect it for human and ecosystem needs. For NAWQA’s third decade (2013–23), a new strategic Science Plan has been developed that describes a strategy for building upon and enhancing the USGS’s ongoing assessment of the Nation’s freshwater quality and aquatic ecosystems.

  10. The water-quality monitoring program for the Baltimore reservoir system, 1981-2007—Description, review and evaluation, and framework integration for enhanced monitoring

    USGS Publications Warehouse

    Koterba, Michael T.; Waldron, Marcus C.; Kraus, Tamara E.C.

    2011-01-01

    The City of Baltimore, Maryland, and parts of five surrounding counties obtain their water from Loch Raven and Liberty Reservoirs. A third reservoir, Prettyboy, is used to resupply Loch Raven Reservoir. Management of the watershed conditions for each reservoir is a shared responsibility by agreement among City, County, and State jurisdictions. The most recent (2005) Baltimore Reservoir Watershed Management Agreement (RWMA) called for continued and improved water-quality monitoring in the reservoirs and selected watershed tributaries. The U.S. Geological Survey (USGS) conducted a retrospective review of the effectiveness of monitoring data obtained and analyzed by the RWMA jurisdictions from 1981 through 2007 to help identify possible improvements in the monitoring program to address RWMA water-quality concerns. Long-term water-quality concerns include eutrophication and sedimentation in the reservoirs, and elevated concentrations of (a) nutrients (nitrogen and phosphorus) being transported from the major tributaries to the reservoirs, (b) iron and manganese released from reservoir bed sediments during periods of deep-water anoxia, (c) mercury in higher trophic order game fish in the reservoirs, and (d) bacteria in selected reservoir watershed tributaries. Emerging concerns include elevated concentrations of sodium, chloride, and disinfection by-products (DBPs) in the drinking water from both supply reservoirs. Climate change and variability also could be emerging concerns, affecting seasonal patterns, annual trends, and drought occurrence, which historically have led to declines in reservoir water quality. Monitoring data increasingly have been used to support the development of water-quality models. The most recent (2006) modeling helped establish an annual sediment Total Maximum Daily Load to Loch Raven Reservoir, and instantaneous and 30-day moving average water-quality endpoints for chlorophyll-a (chl-a) and dissolved oxygen (DO) in Loch Raven and Prettyboy

  11. Why do water quality monitoring programs succeed or fail? A qualitative comparative analysis of regulated testing systems in sub-Saharan Africa.

    PubMed

    Peletz, Rachel; Kisiangani, Joyce; Bonham, Mateyo; Ronoh, Patrick; Delaire, Caroline; Kumpel, Emily; Marks, Sara; Khush, Ranjiv

    2018-05-31

    Water quality testing is critical for guiding water safety management and ensuring public health. In many settings, however, water suppliers and surveillance agencies do not meet regulatory requirements for testing frequencies. This study examines the conditions that promote successful water quality monitoring in Africa, with the goal of providing evidence for strengthening regulated water quality testing programs. We compared monitoring programs among 26 regulated water suppliers and surveillance agencies across six African countries. These institutions submitted monthly water quality testing results over 18 months. We also collected qualitative data on the conditions that influenced testing performance via approximately 821 h of semi-structured interviews and observations. Based on our qualitative data, we developed the Water Capacity Rating Diagnostic (WaterCaRD) to establish a scoring framework for evaluating the effects of the following conditions on testing performance: accountability, staffing, program structure, finances, and equipment & services. We summarized the qualitative data into case studies for each of the 26 institutions and then used the case studies to score the institutions against the conditions captured in WaterCaRD. Subsequently, we applied fuzzy-set Qualitative Comparative Analysis (fsQCA) to compare these scores against performance outcomes for water quality testing. We defined the performance outcomes as the proportion of testing Targets Achieved (outcome 1) and Testing Consistency (outcome 2) based on the monthly number of microbial water quality tests conducted by each institution. Our analysis identified motivation & leadership, knowledge, staff retention, and transport as institutional conditions that were necessary for achieving monitoring targets. In addition, equipment, procurement, infrastructure, and enforcement contributed to the pathways that resulted in strong monitoring performance. Our identification of institutional

  12. DOE-OES-EML quality assurance program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sanderson, C.G.

    1980-01-01

    Contractor laboratories handling radioactive materials for the US Department of Energy (DOE) are required to monitor the environmental exposure and publish annual reports for the Division of Operational and Environmental Safety (OES). In order to determine the validity of the data contained in these reports the Environmental Measurements Laboratory (EML) was requested to develop, coordinate, and conduct an Environmental Quality Assurance Program (QAP). There are four major phases to the DOE-OES-EML Quality Assurance Program: sample collection and preparation, sample analyses at EML, quarterly sample distribution, and reporting the data returned by the participants. The various phases of the QAP andmore » the data reported during the first year of the program are discussed.« less

  13. TIME-RELEVANT BEACH AND RECREATIONAL WATER QUALITY AND MONITORING AND REPORTING

    EPA Science Inventory

    This handbook provides information on how to design and implement a time-relevant water quality monitoring program for beaches and other recreational waters. It was developed to help interested communities learn more about the beach monitoring projects associated with EPA's Envir...

  14. Design and implementation of the National Water-Quality Assessment Program: a United States example: understanding the limitations of using compliance-monitoring data to assess the water quality of a large river basin

    USGS Publications Warehouse

    Wangsness, David J.

    1997-01-01

    In the 1980s it was determined that existing ambient and compliance-monitoring data could not satisfactorily evaluate the results of hundreds of billions of dollars spent for water-pollution abatement in the United States. At the request of the US Congress, a new programme, the National Water-Quality Assessment, was designed and implemented by government agency, the US Geological Survey (USGS). The Assessment has reported status and trends in surface- and ground-water quality at national, regional, and local scales since 1991. The legislative basis for US monitoring and data-sharing policies are identified as well as the successive phases of the design and implementation of the USGS Assessment. Application to the Danube Basin is suggested. Much of the water-quality monitoring conducted in the United States is designed to comply with Federal and State laws mandated primarily by the Clean Water Act of 1987 and the Safe Drinking Water Act of 1986. Monitoring programs generally focus on rivers upstream and downstream of point-source discharges and at water-supply intakes. Few data are available for aquifer systems, and chemical analyses are often limited to those constituents required by law. In most cases, the majority of the available chemical and streamflow data have provided the information necessary to meet the objectives of the compliance-monitoring programs, but do not necessarily provide the information requires for basin-wide assessments of the water quality at the local, regional, or national scale.

  15. Pesticides in Drinking Water – The Brazilian Monitoring Program

    PubMed Central

    Barbosa, Auria M. C.; Solano, Marize de L. M.; Umbuzeiro, Gisela de A.

    2015-01-01

    Brazil is the world largest pesticide consumer; therefore, it is important to monitor the levels of these chemicals in the water used by population. The Ministry of Health coordinates the National Drinking Water Quality Surveillance Program (Vigiagua) with the objective to monitor water quality. Water quality data are introduced in the program by state and municipal health secretariats using a database called Sisagua (Information System of Water Quality Monitoring). Brazilian drinking water norm (Ordinance 2914/2011 from Ministry of Health) includes 27 pesticide active ingredients that need to be monitored every 6 months. This number represents <10% of current active ingredients approved for use in the country. In this work, we analyzed data compiled in Sisagua database in a qualitative and quantitative way. From 2007 to 2010, approximately 169,000 pesticide analytical results were prepared and evaluated, although approximately 980,000 would be expected if all municipalities registered their analyses. This shows that only 9–17% of municipalities registered their data in Sisagua. In this dataset, we observed non-compliance with the minimum sampling number required by the norm, lack of information about detection and quantification limits, insufficient standardization in expression of results, and several inconsistencies, leading to low credibility of pesticide data provided by the system. Therefore, it is not possible to evaluate exposure of total Brazilian population to pesticides via drinking water using the current national database system Sisagua. Lessons learned from this study could provide insights into the monitoring and reporting of pesticide residues in drinking water worldwide. PMID:26581345

  16. Environmental, political, and economic determinants of water quality monitoring in Europe

    NASA Astrophysics Data System (ADS)

    Beck, Lucas; Bernauer, Thomas; Kalbhenn, Anna

    2010-11-01

    Effective monitoring is essential for effective pollution control in national and international water systems. To what extent are countries' monitoring choices driven by environmental criteria, as they should be? And to what extent are they also influenced by other factors, such as political and economic conditions? To address these questions, we describe and explain the evolution of one of the most important international environmental monitoring networks in Europe, the one for water quality, in the time period 1965-2004. We develop a geographic information system that contains information on the location of several thousand active monitoring stations in Europe. Using multivariate statistics, we then examine whether and to what extent the spatial and temporal clustering of monitoring intensity is driven by environmental, political, and economic factors. The results show that monitoring intensity is higher in river basins exposed to greater environmental pressure. However, political and economic factors also play a strong role in monitoring decisions: democracy, income, and peer pressure are conducive to monitoring intensity, and monitoring intensity generally increases over time. Moreover, even though monitoring is more intense in international upstream-downstream settings, we observe only a weak bias toward more monitoring downstream of international borders. In contrast, negative effects of European Union (EU) membership and runup to the EU's Water Framework Directive are potential reasons for concern. Our results strongly suggest that international coordination and standardization of water quality monitoring should be intensified. It will be interesting to apply our analytical approach also to other national and international monitoring networks, for instance, the U.S. National Water-Quality Assessment Program or the European Monitoring and Evaluation Program for air pollution.

  17. A multiyear quality control study of alpha-track radon monitors.

    PubMed

    Pearson, M D; Martz, D E; George, J L; Langner, G H

    1992-01-01

    Quality control exposures of commercial alpha-track radon monitors have been conducted approximately weekly at the U.S. Department of Energy (DOE) Grand Junction Projects Office since early 1987 in support of DOE remedial action programs. The results of these exposures provide a historical record of the comparative performances of these radon monitors.

  18. Water Quality & Pollutant Source Monitoring: Field and Laboratory Procedures. Training Manual.

    ERIC Educational Resources Information Center

    Office of Water Program Operations (EPA), Cincinnati, OH. National Training and Operational Technology Center.

    This training manual presents material on techniques and instrumentation used to develop data in field monitoring programs and related laboratory operations concerned with water quality and pollution monitoring. Topics include: collection and handling of samples; bacteriological, biological, and chemical field and laboratory methods; field…

  19. Chesapeake Bay Program Water Quality Database

    EPA Pesticide Factsheets

    The Chesapeake Information Management System (CIMS), designed in 1996, is an integrated, accessible information management system for the Chesapeake Bay Region. CIMS is an organized, distributed library of information and software tools designed to increase basin-wide public access to Chesapeake Bay information. The information delivered by CIMS includes technical and public information, educational material, environmental indicators, policy documents, and scientific data. Through the use of relational databases, web-based programming, and web-based GIS a large number of Internet resources have been established. These resources include multiple distributed on-line databases, on-demand graphing and mapping of environmental data, and geographic searching tools for environmental information. Baseline monitoring data, summarized data and environmental indicators that document ecosystem status and trends, confirm linkages between water quality, habitat quality and abundance, and the distribution and integrity of biological populations are also available. One of the major features of the CIMS network is the Chesapeake Bay Program's Data Hub, providing users access to a suite of long- term water quality and living resources databases. Chesapeake Bay mainstem and tidal tributary water quality, benthic macroinvertebrates, toxics, plankton, and fluorescence data can be obtained for a network of over 800 monitoring stations.

  20. Using Caffeine as a Water Quality Indicator in the Ambient Monitoring Program for Third Fork Creek Watershed, Durham, North Carolina

    PubMed Central

    Spence, Porché L

    2015-01-01

    Caffeine has been suggested as a chemical indicator for domestic wastewater in freshwater systems, although it is not included in water quality monitoring programs. The Third Fork Creek watershed in Durham, NC, is highly urbanized, with a history of receiving untreated wastewater from leaking and overflowing sanitary sewers. The poor water quality originating in the Third Fork Creek watershed threatens its intended uses and jeopardizes drinking water, aquatic life, and recreational activities provided by Jordan Lake. Organic waste contaminants have been detected in both Third Fork Creek watershed and Jordan Lake; however, the sampling periods were temporary, resulting in a few samples collected during nonstorm periods. It is recommended that (1) the concentration of caffeine and other organic waste contaminants are determined during storm and nonstorm periods and (2) caffeine is monitored regularly with traditional water quality indicators to evaluate the health of Third Fork Creek watershed. PMID:26157335

  1. Standard procedures and quality-control practices for the U.S. Geological Survey National Field Quality Assurance Program from 1982 through 1993

    USGS Publications Warehouse

    Stanley, D.L.

    1995-01-01

    The U.S. Geological Survey operates the National Field Quality Assurance Program to provide quality- assurance reference samples to field personnel who make water-quality field measurements. The program monitors the accuracy and precision of pH, specific conductance, and alkalinity field measurements. This report documents the operational procedures and quality-control techniques used in operating the quality-assurance program.

  2. The Savannah River Site`s Groundwater Monitoring Program. First quarter 1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This report summarizes the Savannah River Site (SRS) groundwater monitoring program conducted during the first quarter of 1992. It includes the analytical data, field data, data review, quality control, and other documentation for this program; provides a record of the program`s activities; and serves as an official document of the analytical results.

  3. An institutional review board-based clinical research quality assurance program.

    PubMed

    Lad, Pramod M; Dahl, Rebecca

    2013-01-01

    Despite the acknowledged importance of quality assurance in the clinical research process, the problem of how such a program should be implemented at the level of an academic teaching hospital or a similar institution has not been addressed in the literature. Despite the fact that quality assurance is expected in programs which certify and accredit Institutional Review Boards (IRBs), very little is known about the role of the IRB in programs of clinical research quality assurance. In this article we consider the definition of clinical research quality assurance, and describe a program designed to achieve it. The key elements of such a program are education at the site level, which has both mandatory and voluntary components, and an auditing and monitoring program, which reinforces the education on quality assurance. The role of the IRB in achieving the program goals and the organizational placement of the quality assurance program within the IRB structure and function are important items of discussion.

  4. A hydrologic retention system and water quality monitoring program for a human decomposition research facility: concept and design.

    PubMed

    Wozniak, Jeffrey R; Thies, Monte L; Bytheway, Joan A; Lutterschmidt, William I

    2015-01-01

    Forensic taphonomy is an essential research field; however, the decomposition of human cadavers at forensic science facilities may lead to nutrient loading and the introduction of unique biological compounds to adjacent areas. The infrastructure of a water retention system may provide a mechanism for the biogeochemical processing and retention of nutrients and compounds, ensuring the control of runoff from forensic facilities. This work provides a proof of concept for a hydrologic retention system and an autonomous water quality monitoring program designed to mitigate runoff from The Southeast Texas Applied Forensic Science (STAFS) Facility. Water samples collected along a sample transect were analyzed for total phosphorous, total nitrogen, NO3-, NO2-, NH4, F(-), and Cl(-). Preliminary water quality analyses confirm the overall effectiveness of the water retention system. These results are discussed with relation to how this infrastructure can be expanded upon to monitor additional, more novel, byproducts of forensic science research facilities. © 2014 American Academy of Forensic Sciences.

  5. In Vivo Monitoring Program Manual, PNL-MA-574

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lynch, Timothy P.

    2010-07-01

    An overview of the administration for the In Vivo Monitoring Program (IVMP) for Hanford. This includes organizational structure and program responsibilities; coordination of in vivo measurements; scheduling measurements; performing measurements; reporting results; and quality assurance. Overall responsibility for the management of the IVMP rests with the Program Manager (PM). The PM is responsible for providing the required in vivo counting services for Hanford Site contractor employees in accordance with Department of Energy (DOE) requirements and the specific statements of work.

  6. Successful water quality monitoring: The right combination of intent, measurement, interpretation, and a cooperating ecosystem

    USGS Publications Warehouse

    Soballe, D.M.

    1998-01-01

    Water quality monitoring is invaluable to ensure compliance with regulations, detect trends or patterns, and advance ecological understanding. However, monitoring typically measures only a few characteristics in a small fraction of a large and complex system, and thus the information contained in monitoring data depends upon which features of the ecosystem are actually captured by the measurements. Difficulties arise when these data contain something other than intended, but this can be minimized if the purpose of the sampling is clear, and the sampling design, measurements, and data interpretations are all compatible with this purpose. The monitoring program and data interpretation must also be properly matched to the structure and functioning of the system. Obtaining this match is sometimes an iterative process that demands a close link between research and monitoring. This paper focuses on water quality monitoring that is intended to track trends in aquatic resources and advance ecological understanding. It includes examples from three monitoring programs and a simulation exercise that illustrate problems that arise when the information content of monitoring data differs from expectation. The examples show (1) how inconsistencies among, or lack of information about, the basic elements of a monitoring program (intent, design, measurement, interpretation, and the monitored system) can produce a systematic difference (bias) between monitoring measurements and sampling intent or interpretation, and (2) that bias is not just a statistical consideration, but an insidious problem that can undermine the scientific integrity of a monitoring program. Some general suggestions are provided and hopefully these examples will help those engaged in water quality monitoring to enhance and protect the value of their monitoring investment.

  7. The North American Amphibian Monitoring Program. [abstract

    USGS Publications Warehouse

    Griffin, J.

    1998-01-01

    The North American Amphibian Monitoring Program has been under development for the past three years. The monitoring strategy for NAAMP has five main prongs: terrestrial salamander surveys, calling surveys, aquatic surveys, western surveys, and atlassing. Of these five, calling surveys were selected as one of the first implementation priorities due to their friendliness to volunteers of varying knowledge levels, relative low cost, and the fact that several groups had already pioneered the techniques involved. While some states and provinces had implemented calling surveys prior to NAAMP, like WI and IL, most states and provinces had little or no history of state/provincewide amphibian monitoring. Thus, the majority of calling survey programs were initiated in the past two years. To assess the progress of this pilot phase, a program review was conducted on the status of the NAAMP calling survey program, and the results of that review will be presented at the meeting. Topics to be discussed include: who is doing what where, extent of route coverage, the continuing random route discussions, quality assurance, strengths and weaknesses of calling surveys, reliability of data, and directions for the future. In addition, a brief overview of the DISPro project will be included. DISPro is a new amphibian monitoring program in National Parks, funded by the Demonstration of Intensive Sites Program (DISPro) through the EPA and NPS. It will begin this year at Big Bend and Shenandoah National Parks. The purpose of the DISPro Amphibian Project will be to investigate relationships between environmental factors and stressors and the distribution, abundance, and health of amphibians in these National Parks. At each Park, amphibian long-term monitoring protocols will be tested, distributions and abundance of amphibians will be mapped, and field research experiments will be conducted to examine stressor effects on amphibians (e.g., ultraviolet radiation, contaminants, acidification).

  8. In Vivo Monitoring Program Manual, PNL-MA-574, Rev 5.1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lynch, Timothy P.

    2011-09-12

    The following sections provide an overview of the administration for the In Vivo Monitoring Program (IVMP) for Hanford. This includes the organizational structure and program responsibilities; coordination of in vivo measurements; scheduling measurements; performing measurements; reporting results; and quality assurance.

  9. The Savannah River Site`s groundwater monitoring program. First quarter 1991

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This report summarizes the Savannah River Site (SRS) groundwater monitoring program conducted by EPD/EMS in the first quarter of 1991. In includes the analytical data, field data, data review, quality control, and other documentation for this program, provides a record of the program`s activities and rationale, and serves as an official document of the analytical results.

  10. Coordinating a national rangeland monitoring training program: Success and lessons learned

    USDA-ARS?s Scientific Manuscript database

    One of the best ways to ensure quality of information gathered in a rangeland monitoring program is through a strong and uniform set of trainings. Curriculum development and delivery of monitoring trainings poses unique challenges that are not seen in academic settings. Participants come from a rang...

  11. Source Water Quality Monitoring

    EPA Science Inventory

    Presentation will provide background information on continuous source water monitoring using online toxicity monitors and cover various tools available. Conceptual and practical aspects of source water quality monitoring will be discussed.

  12. Lot quality assurance sampling (LQAS) for monitoring a leprosy elimination program.

    PubMed

    Gupte, M D; Narasimhamurthy, B

    1999-06-01

    In a statistical sense, prevalences of leprosy in different geographical areas can be called very low or rare. Conventional survey methods to monitor leprosy control programs, therefore, need large sample sizes, are expensive, and are time-consuming. Further, with the lowering of prevalence to the near-desired target level, 1 case per 10,000 population at national or subnational levels, the program administrator's concern will be shifted to smaller areas, e.g., districts, for assessment and, if needed, for necessary interventions. In this paper, Lot Quality Assurance Sampling (LQAS), a quality control tool in industry, is proposed to identify districts/regions having a prevalence of leprosy at or above a certain target level, e.g., 1 in 10,000. This technique can also be considered for identifying districts/regions at or below the target level of 1 per 10,000, i.e., areas where the elimination level is attained. For simulating various situations and strategies, a hypothetical computerized population of 10 million persons was created. This population mimics the actual population in terms of the empirical information on rural/urban distributions and the distribution of households by size for the state of Tamil Nadu, India. Various levels with respect to leprosy prevalence are created using this population. The distribution of the number of cases in the population was expected to follow the Poisson process, and this was also confirmed by examination. Sample sizes and corresponding critical values were computed using Poisson approximation. Initially, villages/towns are selected from the population and from each selected village/town households are selected using systematic sampling. Households instead of individuals are used as sampling units. This sampling procedure was simulated 1000 times in the computer from the base population. The results in four different prevalence situations meet the required limits of Type I error of 5% and 90% Power. It is concluded that

  13. The Upper Colorado River; National Water-Quality Assessment Program; surface-water-monitoring network

    USGS Publications Warehouse

    Spahr, Norman E.; Driver, Nancy E.; Stephens, Verlin C.

    1996-01-01

    The U.S. Geological Survey began full implementation of the National Water-Quality Assessment (NAWQA) program in 1991. The long-term goals of the NAWQA program are to (1) describe current water-quality conditions for a large part of the Nation's freshwater streams, rivers, and aquifers; (2) describe how water quality is changing over time; and (3) improve understanding of the primary natural and human factors that affect water-quality conditions (Leahy and others, 1990). To meet these goals, 60 study units representing the Nation's most important river basins and aquifers are being investigated. The program design balances the unique assessment requirements of individual study units with a nationally consistent design structure that incorporates a multiscale, interdisciplinary approach for assessment of surface and ground water.

  14. Review of present groundwater monitoring programs at the Nevada Test Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hershey, R.L.; Gillespie, D.

    1993-09-01

    Groundwater monitoring at the Nevada Test Site (NTS) is conducted to detect the presence of radionuclides produced by underground nuclear testing and to verify the quality and safety of groundwater supplies as required by the State of Nevada and federal regulations, and by U.S. Department of Energy (DOE) Orders. Groundwater is monitored at water-supply wells and at other boreholes and wells not specifically designed or located for traditional groundwater monitoring objectives. Different groundwater monitoring programs at the NTS are conducted by several DOE Nevada Operations Office (DOE/NV) contractors. Presently, these individual groundwater monitoring programs have not been assessed or administeredmore » under a comprehensive planning approach. Redundancy exists among the programs in both the sampling locations and the constituents analyzed. Also, sampling for certain radionuclides is conducted more frequently than required. The purpose of this report is to review the existing NTS groundwater monitoring programs and make recommendations for modifying the programs so a coordinated, streamlined, and comprehensive monitoring effort may be achieved by DOE/NV. This review will be accomplished in several steps. These include: summarizing the present knowledge of the hydrogeology of the NTS and the potential radionuclide source areas for groundwater contamination; reviewing the existing groundwater monitoring programs at the NTS; examining the rationale for monitoring and the constituents analyzed; reviewing the analytical methods used to quantify tritium activity; discussing monitoring network design criteria; and synthesizing the information presented and making recommendations based on the synthesis. This scope of work was requested by the DOE/NV Hydrologic Resources Management Program (HRMP) and satisfies the 1993 (fiscal year) HRMP Groundwater Monitoring Program Review task.« less

  15. Stormwater runoff water quality evaluation and management program for hazardous chemical sites: Development issues

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, G.F.; Jones-Lee, A.

    1998-12-31

    The deficiencies in the typical stormwater runoff water quality monitoring from hazardous chemical sites and an alternative approach (Evaluation Monitoring) for monitoring that shifts the monitoring program from periodic sampling and analysis of stormwater runoff for a suite of chemical parameters to examining the receiving waters to determine what, if any, water quality use impairments are occurring due to the runoff-associated constituents is presented in this paper. Rather than measuring potentially toxic constituents such as heavy metals in runoff, the monitoring program determines whether there is aquatic life toxicity in the receiving waters associated with the stormwater runoff. If toxicitymore » is found, its cause is determined and the source of the constituents causing the toxicity is identified through forensic analysis. Based on this information, site-specific, technically valid stormwater runoff management programs can be developed that will control real water quality impacts caused by stormwater runoff-associated constituents.« less

  16. Quality Assurance and Control Considerations in Environmental Measurements and Monitoring

    NASA Astrophysics Data System (ADS)

    Sedlet, Jacob

    1982-06-01

    Quality assurance and quality control have become accepted as essential parts of all environmental surveillance, measurements, and monitoring programs, both nuclear and non-nuclear. The same principles and details apply to each. It is primarily the final measurement technique that differs. As the desire and need to measure smaller amounts of pollutants with greater accuracy has increased, it has been recognized that quality assurance and control programs are cost-effective in achieving the expected results. Quality assurance (QA) consists of all the actions necessary to provide confidence in the results. Quality control (QC) is a part of QA, and consists of those actions and activities that permit the control of the individual steps in the environmental program. The distinction between the two terms is not always clearly defined, but a sharp division is not necessary. The essential principle of QA and QC is a commitment to high quality results. The essential components of a QA and QC program are a complete, written procedures manual for all parts of the environmental program, the use of standard or validated procedures, participation in applicable interlaboratory comparison or QA programs, replicate analysis and measurement, training of personnel, and a means of auditing or checking that the QA and QC programs are properly conducted. These components are discussed below in some detail.

  17. Making quality improvement programs more effective.

    PubMed

    Shaw-Taylor, Yoku

    2014-01-01

    In the past 25 years, and as recent as 2011, all external evaluations of the Quality Improvement Organization (QIO) Program have found its impact to be small or difficult to discern. The QIO program costs about $200 million on average to administer each year to improve quality of healthcare for people of 65 years or older. The program was created to address questionable quality of care. QIOs review how care is provided based on performance measures. The paper aims to discuss these issues. In 2012, the author supported the production of quarterly reports and reviewed internal monitoring and evaluation protocols of the program. The task also required reviewing all previous program evaluations. The task involved many conversations about the complexities of the program, why impact is difficult to discern and possible ways for eventual improvement. Process flow charts were created to simulate the data life cycle and discrete event models were created based on the sequence of data collection and reporting to identify gaps in data flow. The internal evaluation uncovered data gaps within the program. The need for a system of specification rules for data conceptualization, collection, distribution, discovery, analysis and repurposing is clear. There were data inconsistencies and difficulty of integrating data from one instance of measurement to the next. The lack of good and reliable data makes it difficult to discern true impact. The prescription is for a formal data policy or data governance structure to integrate and document all aspects of the data life cycle. The specification rules for governance are exemplified by the Data Documentation Initiative and the requirements published by the Data Governance Institute. The elements are all in place for a solid foundation of the data governance structure. These recommendations will increase the value of program data. The model specifies which agency units must be included in the governance authority and the data team. The

  18. Groundwater Monitoring Plan. Volume 2. Final Quality Assurance Project Plan

    DTIC Science & Technology

    1993-10-01

    5 Table 4-2. US EPA Drinking Water MCLs ........................................ 4-6 Table 5-1. Sample Bottle Requirements, Preservation, and Holding... drinking water . " The types of quality control samples that will be collected during the Canal Creek groundwater monitoring program. ]- Jacobs...Revision No.: 0 Date: 10/27/93 Page: 6 of 9 Canal Creek Area, APG-EA, Maryland Groundwater Monitoring Plan, VOLUME I1 Table 4-2. US EPA Drinking Water

  19. [The marine coastal water monitoring program of the Italian Ministry of the Environment].

    PubMed

    Di Girolamo, Irene

    2003-01-01

    The Ministry of the Environment carries out marine and coastal monitoring programs with the collaboration of the coastal Regions. The program in progress (2001-2003), on the basis of results of the previous one, has identified 73 particulary significant areas (57 critical areas and 16 control areas). The program investigates several parameters on water, plancton, sediments, mollusks and benthos with analyses fortnightly, six-monthly and annual. The main aim of these three year monitoring programs is to assess the quality of national marine ecosystem.

  20. Drinking water quality and public health in Southwestern Saudi Arabia: The need for a national monitoring program.

    PubMed

    Alqahtani, Jobran M; Asaad, Ahmed M; Ahmed, Essam M; Qureshi, Mohamed A

    2015-01-01

    The aim was to investigate the bacteriological quality of drinking water, and explore the factors involved in the knowledge of the public about the quality of drinking water in Najran region, Saudi Arabia. A cross-sectional descriptive study. A total of 160 water samples were collected. Total coliforms, fecal coliform, and fecal streptococci were counted using Most Probable Number method. The bacterial genes lacZ and uidA specific to total coliforms and Escherichia coli, respectively, were detected using multiplex polymerase chain reaction. An interview was conducted with 1200 residents using a questionnaire. Total coliforms were detected in 8 (20%) of 40 samples from wells, 13 (32.5%) of 40 samples from tankers, and 55 (68.8%) of 80 samples from roof tanks. Twenty (25%) and 8 (10%) samples from roof tanks were positive for E. coli and Streptococcus faecalis, respectively. Of the 1200 residents participating in the study, 10%, 45.5%, and 44.5% claimed that they depended on municipal water, bottled water, and well water, respectively. The majority (95.5%) reported the use of roof water tanks as a source of water supply in their homes. Most people (80%) believed that drinking water transmitted diseases. However, only 25% of them participated in educational programs on the effect of polluted water on health. Our results could help health authorities consider a proper regular monitoring program and a sustainable continuous assessment of the quality of well water. In addition, this study highlights the importance of the awareness and educational programs for residents on the effect of polluted water on public health.

  1. Real-time water quality monitoring and providing water quality ...

    EPA Pesticide Factsheets

    EPA and the U.S. Geological Survey (USGS) have initiated the “Village Blue” research project to provide real-time water quality monitoring data to the Baltimore community and increase public awareness about local water quality in Baltimore Harbor and the Chesapeake Bay. The Village Blue demonstration project complements work that a number of state and local organizations are doing to make Baltimore Harbor “swimmable and fishable” 2 by 2020. Village Blue is designed to build upon EPA’s “Village Green” project which provides real-time air quality information to communities in six locations across the country. The presentation, “Real-time water quality monitoring and providing water quality information to the Baltimore Community”, summarizes the Village Blue real-time water quality monitoring project being developed for the Baltimore Harbor.

  2. Air Quality Monitoring: Risk-Based Choices

    NASA Technical Reports Server (NTRS)

    James, John T.

    2009-01-01

    Air monitoring is secondary to rigid control of risks to air quality. Air quality monitoring requires us to target the credible residual risks. Constraints on monitoring devices are severe. Must transition from archival to real-time, on-board monitoring. Must provide data to crew in a way that they can interpret findings. Dust management and monitoring may be a major concern for exploration class missions.

  3. Comparison and cost analysis of drinking water quality monitoring requirements versus practice in seven developing countries.

    PubMed

    Crocker, Jonny; Bartram, Jamie

    2014-07-18

    Drinking water quality monitoring programs aim to support provision of safe drinking water by informing water quality management. Little evidence or guidance exists on best monitoring practices for low resource settings. Lack of financial, human, and technological resources reduce a country's ability to monitor water supply. Monitoring activities were characterized in Cambodia, Colombia, India (three states), Jordan, Peru, South Africa, and Uganda according to water sector responsibilities, monitoring approaches, and marginal cost. The seven study countries were selected to represent a range of low resource settings. The focus was on monitoring of microbiological parameters, such as E. coli, coliforms, and H2S-producing microorganisms. Data collection involved qualitative and quantitative methods. Across seven study countries, few distinct approaches to monitoring were observed, and in all but one country all monitoring relied on fixed laboratories for sample analysis. Compliance with monitoring requirements was highest for operational monitoring of large water supplies in urban areas. Sample transport and labor for sample collection and analysis together constitute approximately 75% of marginal costs, which exclude capital costs. There is potential for substantive optimization of monitoring programs by considering field-based testing and by fundamentally reconsidering monitoring approaches for non-piped supplies. This is the first study to look quantitatively at water quality monitoring practices in multiple developing countries.

  4. Quality assurance in postgraduate pathology training the Dutch way: regular assessment, monitoring of training programs but no end of training examination.

    PubMed

    van der Valk, Paul

    2016-01-01

    It might seem self-evident that in the transition from a supervised trainee to an independent professional who is no longer supervised, formal assessment of whether the trainee knows his/her trade well enough to function independently is necessary. This would then constitute an end of training examination. Such examinations are practiced in several countries but a rather heterogeneous situation exists in the EU countries. In the Netherlands, the training program is not concluded by a summative examination and reasons behind this situation are discussed. Quality assurance of postgraduate medical training in the Netherlands has been developed along two tracks: (1) not a single testing moment but continuous evaluation of the performance of the trainee in 'real time' situations and (2) monitoring of the quality of the offered training program through regular site-visits. Regular (monthly and/or yearly) evaluations should be part of every self-respecting training program. In the Netherlands, these evaluations are formative only: their intention is to provide the trainee a tool by which he or she can see whether they are on track with their training schedule. In the system in the Netherlands, regular site-visits to training programs constitute a crucial element of quality assurance of postgraduate training. During the site-visit, the position and perceptions of the trainee are key elements. The perception by the trainee of the training program, the institution (or department) offering the training program, and the professionals involved in the training program is explicitly solicited and systematically assessed. With this two-tiered approach high-quality postgraduate training is assured without the need for an end of training examination.

  5. Real-time video quality monitoring

    NASA Astrophysics Data System (ADS)

    Liu, Tao; Narvekar, Niranjan; Wang, Beibei; Ding, Ran; Zou, Dekun; Cash, Glenn; Bhagavathy, Sitaram; Bloom, Jeffrey

    2011-12-01

    The ITU-T Recommendation G.1070 is a standardized opinion model for video telephony applications that uses video bitrate, frame rate, and packet-loss rate to measure the video quality. However, this model was original designed as an offline quality planning tool. It cannot be directly used for quality monitoring since the above three input parameters are not readily available within a network or at the decoder. And there is a great room for the performance improvement of this quality metric. In this article, we present a real-time video quality monitoring solution based on this Recommendation. We first propose a scheme to efficiently estimate the three parameters from video bitstreams, so that it can be used as a real-time video quality monitoring tool. Furthermore, an enhanced algorithm based on the G.1070 model that provides more accurate quality prediction is proposed. Finally, to use this metric in real-world applications, we present an example emerging application of real-time quality measurement to the management of transmitted videos, especially those delivered to mobile devices.

  6. Monitoring air quality in Southeast Alaska’s National Parks and Forests: Linking atmospheric pollutants with ecological effects

    Treesearch

    D. Schirokauer; L. Geiser; A. Bytnerowicz; M. Fenn; K. Dillman

    2014-01-01

    Air quality and air quality related values are important resources to the National Park Service (NPS) units and Wilderness areas in northern Southeast Alaska. Air quality monitoring was prioritized as a high-priority Vital Sign at the Southeast Alaska Network’s (SEAN) Inventory and Monitoring Program’s terrestrial scoping workshop (Derr and Fastie 2006). Air quality...

  7. Developing the Tools for Geologic Repository Monitoring - Andra's Monitoring R and D Program - 12045

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buschaert, S.; Lesoille, S.; Bertrand, J.

    2012-07-01

    The French Safety Guide recommends that Andra develop a monitoring program to be implemented during repository construction and conducted until (and possibly after) closure, in order to confirm expected behavior and enhance knowledge of relevant processes. To achieve this, Andra has developed an overall monitoring strategy and identified specific technical objectives to inform disposal process management on evolutions relevant to both the long term safety and reversible, pre-closure management of the repository. Andra has launched an ambitious R and D program to ensure that reliable, durable, metrologically qualified and tested monitoring systems will be available at the time of repositorymore » construction in order to respond to monitoring objectives. After four years of a specific R and D program, first observations are described and recommendations are proposed. The results derived from 4 years of Andra's R and D program allow three main observations to be shared. First, while other industries also invest in monitoring equipment, their obvious emphasis will always be on their specific requirements and needs, thus often only providing a partial match with repository requirements. Examples can be found for all available sensors, which are generally not resistant to radiation. Second, the very close scrutiny anticipated for the geologic disposal process is likely to place an unprecedented emphasis on the quality of monitoring results. It therefore seems important to emphasize specific developments with an aim at providing metrologically qualified systems. Third, adapting existing technology to specific repository needs, and providing adequate proof of their worth, is a lengthy process. In conclusion, it therefore seems prudent to plan ahead and to invest wisely in the adequate development of those monitoring tools that will likely be needed in the repository to respond to the implementers' and regulators' requirements, including those agreed and developed to

  8. Water quality variability in San Francisco Bay, Some gGeneral lessons from 1996 sampling: 1996 annual report, San Francisco estuary regional monitoring program for trace substances

    USGS Publications Warehouse

    Cloern, J.E.; Cole, B.E.; Edmunds, J.L.; Baylosis, J.I.

    1997-01-01

    This report describes the results from the 1996 Regional Monitoring Program for Trace Substances (RMP). It is the fourth Annual Report from the RMP which began in 1993 and attempts to synthesize the most obvious data patterns from the last four years. This report includes data from Base Program monitoring activities, as well as results of Pilot and Special Studies conducted or completed in 1996. Additionally, several articles contributed by RMP investigators and others, are included. These articles provide perspective and insight on important contaminant issues identified by the RMP. This summary addresses which kinds of pollutants measured by the RMP appear to be at levels that warrant concern, what kinds of trends may be discerned, and which stations have consistently shown elevated contaminant levels. The goals or general objectives of the RMP are: 1. To obtain high quality baseline data describing the concentrations of toxic and potentially toxic trace elements and organic contaminants in the water and sediment of the San Francisco Estuary. 2. To determine seasonal and annual trends in chemical and biological water quality in the San Francisco Estuary. 3. To continue to develop a data set that can be used to determine long-term trends in the concentrations of toxic and potentially toxic trace elements and organic contaminants in the water and sediments of the San Francisco Estuary. 4. To determine whether water quality and sediment quality in the Estuary at large are in compliance with objectives established by the Basin Plan (the regulatory planning document used by the Regional Water Quality Control Board). 5. To provide a database on water and sediment quality in the Estuary which is compatible with data being developed in other ongoing studies, including wasteload allocation studies and model development, sediment quality objectives development, in-bay studies of dredged material disposal, Interagency Ecological Program (IEP) water quality studies, primary

  9. Characterizing the Breadth and Depth of Volunteer Water Monitoring Programs in the United States.

    PubMed

    Stepenuck, Kristine F; Genskow, Kenneth D

    2018-01-01

    A survey of 345 volunteer water monitoring programs in the United States was conducted to document their characteristics, and perceived level of support for data to inform natural resource management or policy decisions. The response rate of 86% provided information from 46 states. Programs represented a range of ages, budgets, objectives, scopes, and level of quality assurance, which influenced data uses and perceived support by sponsoring agency administrators and external decision makers. Most programs focused on rivers, streams, and lakes. Programs had not made substantial progress to develop EPA or state-approved quality assurance plans since 1998, with only 48% reporting such plans. Program coordinators reported feeling slightly more support for data to be used for management as compared to policy decisions. Programs with smaller budgets may be at particular risk of being perceived to lack credibility due to failure to develop quality assurance plans. Over half of programs identified as collaborative, in that volunteers assisted scientists in program design, data analysis and/or dissemination of results. Just under a third were contributory, in which volunteers primarily collected data in a scientist-defined program. Recommendations to improve perceived data credibility, and to augment limited budgets include developing quality assurance plans and gaining agency approval, and developing partnerships with other organizations conducting monitoring in the area to share resources and knowledge. Funding agencies should support development of quality assurance plans to help ensure data credibility. Service providers can aid in plan development by providing training to program staff over time to address high staff turnover rates.

  10. Characterizing the Breadth and Depth of Volunteer Water Monitoring Programs in the United States

    NASA Astrophysics Data System (ADS)

    Stepenuck, Kristine F.; Genskow, Kenneth D.

    2018-01-01

    A survey of 345 volunteer water monitoring programs in the United States was conducted to document their characteristics, and perceived level of support for data to inform natural resource management or policy decisions. The response rate of 86% provided information from 46 states. Programs represented a range of ages, budgets, objectives, scopes, and level of quality assurance, which influenced data uses and perceived support by sponsoring agency administrators and external decision makers. Most programs focused on rivers, streams, and lakes. Programs had not made substantial progress to develop EPA or state-approved quality assurance plans since 1998, with only 48% reporting such plans. Program coordinators reported feeling slightly more support for data to be used for management as compared to policy decisions. Programs with smaller budgets may be at particular risk of being perceived to lack credibility due to failure to develop quality assurance plans. Over half of programs identified as collaborative, in that volunteers assisted scientists in program design, data analysis and/or dissemination of results. Just under a third were contributory, in which volunteers primarily collected data in a scientist-defined program. Recommendations to improve perceived data credibility, and to augment limited budgets include developing quality assurance plans and gaining agency approval, and developing partnerships with other organizations conducting monitoring in the area to share resources and knowledge. Funding agencies should support development of quality assurance plans to help ensure data credibility. Service providers can aid in plan development by providing training to program staff over time to address high staff turnover rates.

  11. Drinking water quality and public health in Southwestern Saudi Arabia: The need for a national monitoring program

    PubMed Central

    Alqahtani, Jobran M.; Asaad, Ahmed M.; Ahmed, Essam M.; Qureshi, Mohamed A.

    2015-01-01

    Aim of the Study: The aim was to investigate the bacteriological quality of drinking water, and explore the factors involved in the knowledge of the public about the quality of drinking water in Najran region, Saudi Arabia. Study Design: A cross-sectional descriptive study. Materials and Methods: A total of 160 water samples were collected. Total coliforms, fecal coliform, and fecal streptococci were counted using Most Probable Number method. The bacterial genes lacZ and uidA specific to total coliforms and Escherichia coli, respectively, were detected using multiplex polymerase chain reaction. An interview was conducted with 1200 residents using a questionnaire. Results: Total coliforms were detected in 8 (20%) of 40 samples from wells, 13 (32.5%) of 40 samples from tankers, and 55 (68.8%) of 80 samples from roof tanks. Twenty (25%) and 8 (10%) samples from roof tanks were positive for E. coli and Streptococcus faecalis, respectively. Of the 1200 residents participating in the study, 10%, 45.5%, and 44.5% claimed that they depended on municipal water, bottled water, and well water, respectively. The majority (95.5%) reported the use of roof water tanks as a source of water supply in their homes. Most people (80%) believed that drinking water transmitted diseases. However, only 25% of them participated in educational programs on the effect of polluted water on health. Conclusions: Our results could help health authorities consider a proper regular monitoring program and a sustainable continuous assessment of the quality of well water. In addition, this study highlights the importance of the awareness and educational programs for residents on the effect of polluted water on public health. PMID:25657607

  12. Walnut creek watershed monitoring project, Iowa: Monitoring water quality in response to prairie restoration

    USGS Publications Warehouse

    Schilling, K.E.; Thompson, C.A.

    2000-01-01

    Land use and surface water data for nitrogen and pesticides (1995 to 1997) are reported for the Walnut Creek Watershed Monitoring Project, Jasper County Iowa. The Walnut Creek project was established in 1995 as a nonpoint source monitoring program in relation to watershed habitat restoration and agricultural management changes implemented at the Neal Smith National Wildlife Refuge by the U.S. Fish and Wildlife Service. The monitoring project utilizes a paired-watershed approach (Walnut and Squaw creeks) as well as upstream/downstream comparisons on Walnut for analysis and tracking of trends. From 1992 to 1997, 13.4 percent of the watershed was converted from row crop to native prairie in the Walnut Creek watershed. Including another 6 percent of watershed farmed on a cash-rent basis, land use changes have been implemented on 19.4 percent of the watershed by the USFWS. Nitrogen and pesticide applications were reduced an estimated 18 percent and 28 percent in the watershed from land use changes. Atrazine was detected most often in surface water with frequencies of detection ranging from 76-86 percent. No significant differences were noted in atrazine concentrations between Walnut and Squaw Creek. Nitrate-N concentrations measured in both watersheds were similar; both basins showed a similar pattern of detection and an overall reduction in nitrate-N concentrations from upstream to downstream monitoring sites. Water quality improvements are suggested by nitrate-N and chloride ratios less than one in the Walnut Creek watershed and low nitrate-N concentrations measured in the subbasin of Walnut Creek containing the greatest amount of land use changes. Atrazine and nitrate-N concentrations from the lower portion of the Walnut Creek watershed (including the prairie restoration area) may be decreasing in relation to the upstream untreated component of the watershed. The frequencies of pesticide detections and mean nitrate-N concentrations appear related to the percentage of

  13. Comparison and Cost Analysis of Drinking Water Quality Monitoring Requirements versus Practice in Seven Developing Countries

    PubMed Central

    Crocker, Jonny; Bartram, Jamie

    2014-01-01

    Drinking water quality monitoring programs aim to support provision of safe drinking water by informing water quality management. Little evidence or guidance exists on best monitoring practices for low resource settings. Lack of financial, human, and technological resources reduce a country’s ability to monitor water supply. Monitoring activities were characterized in Cambodia, Colombia, India (three states), Jordan, Peru, South Africa, and Uganda according to water sector responsibilities, monitoring approaches, and marginal cost. The seven study countries were selected to represent a range of low resource settings. The focus was on monitoring of microbiological parameters, such as E. coli, coliforms, and H2S-producing microorganisms. Data collection involved qualitative and quantitative methods. Across seven study countries, few distinct approaches to monitoring were observed, and in all but one country all monitoring relied on fixed laboratories for sample analysis. Compliance with monitoring requirements was highest for operational monitoring of large water supplies in urban areas. Sample transport and labor for sample collection and analysis together constitute approximately 75% of marginal costs, which exclude capital costs. There is potential for substantive optimization of monitoring programs by considering field-based testing and by fundamentally reconsidering monitoring approaches for non-piped supplies. This is the first study to look quantitatively at water quality monitoring practices in multiple developing countries. PMID:25046632

  14. Alternative indicators for monitoring the quality of a continuous intervention program on antibiotic prescribing during changing healthcare conditions.

    PubMed

    Bantar, C; Franco, D; Heft, C; Vesco, E; Arango, C; Izaguirre, M; Alcázar, G; Boleas, M; Oliva, M E

    2005-06-01

    We recently published on the impact of a four-phase hospital-wide intervention program designed to optimize the quality of antibiotic use, where a multidisciplinary team (MDT) could modify prescription at the last phase. Because health care quality was changing during the last 5 years (late 1999 to early 2004), we developed certain indicators to monitor the quality of our intervention over time. Different periods were defined as baseline (pre-intervention), initial intervention-active control, pre-crisis control, crisis control, post-crisis control and end of crisis control. Major indicators were rates of prescription modification by the MDT; prescription for an uncertain infection and a novel index formula (RIcarb) to estimate the rationale for carbapenem use. We assessed 2115 antimicrobial prescriptions. Modification of prescription rate was 30% at the beginning and decreased thereafter up to stable levels. Rate of prescriptions ordered for cases of both uncertain infection and unknown source of infection decreased significantly after intervention (i.e. from baseline to active control). In contrast, a doubling of culture-directed prescriptions was observed between these periods. RIcarb values lower and higher than 60% (modal, cut-off) were assumed as carbapenem overuse and underuse, respectively. Overuse was observed at the pre-intervention, while pronounced underuse was shown during the crisis (RIcarb, 45% and 87%, respectively). The present study demonstrates that certain indicators, other than the widely adopted impact outcomes, are a suitable tool for monitoring the quality of a continuous, long-term, active intervention on antimicrobial prescribing practice, especially when applied in a changing healthcare setting.

  15. Quality management of Body Donation Program at the University of Padova.

    PubMed

    Porzionato, Andrea; Macchi, Veronica; Stecco, Carla; Mazzi, Anna; Rambaldo, Anna; Sarasin, Gloria; Parenti, Anna; Scipioni, Antonio; De Caro, Raffaele

    2012-01-01

    Quality management improvement has become a recent focus of attention in medical education. The program for the donation of bodies and body parts (Body Donation Program) at the University of Padova has recently been subjected to a global quality management standard, the ISO 9001:2008 certification. The aim of the present work is to show how the above standard is useful in enhancing the efficiency of body donation procedures and the quality and output of medical education. The program is managed by means of the following interlinked procedures: the collection of body donations, death certificates, data, and body parts from living donors; the transportation and identification of cadavers; the management of bodies, body parts, equipment, instruments, purchasing of necessary materials, and setting up anatomical training sessions; the management of preventive and corrective actions; the management of documents and registration; the management of internal and external quality audits; and the review of outcomes and improvement planning. Monitoring indicators are identified in the numbers of donors and of donated body parts per year, education sessions, and satisfaction of learners and donors, as evaluated by questionnaires. The process management approach, the integrated involvement of medical, technical, and administrative staff in defining procedures, and the application of monitoring indicators allow quality improvement in all aspects of the Body Donation Program. Copyright © 2012 American Association of Anatomists.

  16. Developing a quality assurance program for online services.

    PubMed Central

    Humphries, A W; Naisawald, G V

    1991-01-01

    A quality assurance (QA) program provides not only a mechanism for establishing training and competency standards, but also a method for continuously monitoring current service practices to correct shortcomings. The typical QA cycle includes these basic steps: select subject for review, establish measurable standards, evaluate existing services using the standards, identify problems, implement solutions, and reevaluate services. The Claude Moore Health Sciences Library (CMHSL) developed a quality assurance program for online services designed to evaluate services against specific criteria identified by research studies as being important to customer satisfaction. These criteria include reliability, responsiveness, approachability, communication, and physical factors. The application of these criteria to the library's existing online services in the quality review process is discussed with specific examples of the problems identified in each service area, as well as the solutions implemented to correct deficiencies. The application of the QA cycle to an online services program serves as a model of possible interventions. The use of QA principles to enhance online service quality can be extended to other library service areas. PMID:1909197

  17. Developing a quality assurance program for online services.

    PubMed

    Humphries, A W; Naisawald, G V

    1991-07-01

    A quality assurance (QA) program provides not only a mechanism for establishing training and competency standards, but also a method for continuously monitoring current service practices to correct shortcomings. The typical QA cycle includes these basic steps: select subject for review, establish measurable standards, evaluate existing services using the standards, identify problems, implement solutions, and reevaluate services. The Claude Moore Health Sciences Library (CMHSL) developed a quality assurance program for online services designed to evaluate services against specific criteria identified by research studies as being important to customer satisfaction. These criteria include reliability, responsiveness, approachability, communication, and physical factors. The application of these criteria to the library's existing online services in the quality review process is discussed with specific examples of the problems identified in each service area, as well as the solutions implemented to correct deficiencies. The application of the QA cycle to an online services program serves as a model of possible interventions. The use of QA principles to enhance online service quality can be extended to other library service areas.

  18. Monitoring quality in Israeli primary care: The primary care physicians' perspective

    PubMed Central

    2012-01-01

    Background Since 2000, Israel has had a national program for ongoing monitoring of the quality of the primary care services provided by the country's four competing non-profit health plans. Previous research has demonstrated that quality of care has improved substantially since the program's inception and that the program enjoys wide support among health plan managers. However, prior to this study there were anecdotal and journalistic reports of opposition to the program among primary care physicians engaged in direct service delivery; these raised serious questions about the extent of support among physicians nationally. Goals To assess how Israeli primary care physicians experience and rate health plan efforts to track and improve the quality of care. Method The study population consisted of primary care physicians employed by the health plans who have responsibility for the quality of care of a panel of adult patients. The study team randomly sampled 250 primary-care physicians from each of the four health plans. Of the 1,000 physicians sampled, 884 met the study criteria. Every physician could choose whether to participate in the survey by mail, e-mail, or telephone. The anonymous questionnaire was completed by 605 physicians – 69% of those eligible. The data were weighted to reflect differences in sampling and response rates across health plans. Main findings The vast majority of respondents (87%) felt that the monitoring of quality was important and two-thirds (66%) felt that the feedback and subsequent remedial interventions improved medical care to a great extent. Almost three-quarters (71%) supported continuation of the program in an unqualified manner. The physicians with the most positive attitudes to the program were over age 44, independent contract physicians, and either board-certified in internal medicine or without any board-certification (i.e., residents or general practitioners). At the same time, support for the program was widespread even

  19. Development of a quality assurance program for ionizing radiation secondary calibration laboratories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heaton, H.T. II; Taylor, A.R. Jr.

    For calibration laboratories, routine calibrations of instruments meeting stated accuracy goals are important. One method of achieving the accuracy goals is to establish and follow a quality assurance program designed to monitor all aspects of the calibration program and to provide the appropriate feedback mechanism if adjustments are needed. In the United States there are a number of organizations with laboratory accreditation programs. All existing accreditation programs require that the laboratory implement a quality assurance program with essentially the same elements in all of these programs. Collectively, these elements have been designated as a Measurement Quality Assurance (MQA) program. Thismore » paper will briefly discuss the interrelationship of the elements of an MQA program. Using the Center for Devices and Radiological Health (CDRH) X-ray Calibration Laboratory (XCL) as an example, it will focus on setting up a quality control program for the equipment in a Secondary Calibration Laboratory.« less

  20. Adventures in Citizen Science: Lessons learned engaging volunteer water quality monitors for over 30 years.

    NASA Astrophysics Data System (ADS)

    Schloss, J. A.

    2012-12-01

    The New Hampshire Lakes Lay Monitoring Program was originally designed by faculty at the University of New Hampshire in 1979 to provide the capacity to better monitor for long-term lake water quality changes and trends. As participants became educated, empowered and engaged the program soon evolved to also become a participatory research enterprise. This resulted in not only providing useful information for informed local stewardship and protection at the local level but also for state and region-wide decision-making, state and federal assessments/reporting and advancing our understanding of lake and watershed science. Our successes and failures have been more dependent on understanding the particular human dimensions that influence our volunteers and less to do with the typical project management, quality assurance, and communication concerns we typically deal with in professional based research efforts. Our participants are extremely diverse in terms of their life experiences, interests and motivations so the key to long-term commitment and high quality participation is understanding the difference between a citizen monitor and your archetypical research technician or student. This presentation will highlight some important lessons learned on how to involve various types of volunteers from school groups to retirees, as well as particular approaches and concerns regarding program management, retention, quality control and communications.

  1. 40 CFR 130.4 - Water quality monitoring.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... QUALITY PLANNING AND MANAGEMENT § 130.4 Water quality monitoring. (a) In accordance with section 106(e)(1...; developing and reviewing water quality standards, total maximum daily loads, wasteload allocations and load... 40 Protection of Environment 21 2010-07-01 2010-07-01 false Water quality monitoring. 130.4...

  2. 40 CFR 130.4 - Water quality monitoring.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... QUALITY PLANNING AND MANAGEMENT § 130.4 Water quality monitoring. (a) In accordance with section 106(e)(1...; developing and reviewing water quality standards, total maximum daily loads, wasteload allocations and load... 40 Protection of Environment 22 2011-07-01 2011-07-01 false Water quality monitoring. 130.4...

  3. Final report on the waste area grouping perimeter groundwater quality monitoring well installation program at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Greene, J.A.

    1991-06-01

    A groundwater quality monitoring well installation program was conducted at Oak Ridge National Laboratory (ORNL) to meet the requirements of environmental regulations, including the Resource Conservation and Recovery Act (RCRA) and the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). A total of 173 wells were installed and developed at 11 different waste area groupings (WAGs) between June 1986 and November 1990. A location map of the wells is included.

  4. Participation Rates, Process Monitoring, and Quality Improvement Among Cardiac Rehabilitation Programs in the United States: A NATIONAL SURVEY.

    PubMed

    Pack, Quinn R; Squires, Ray W; Lopez-Jimenez, Francisco; Lichtman, Steven W; Rodriguez-Escudero, Juan P; Lindenauer, Peter K; Thomas, Randal J

    2015-01-01

    Although strategies exist for improving cardiac rehabilitation (CR) participation rates, it is unclear how frequently these strategies are used and what efforts are being made by CR programs to improve participation rates. We surveyed all CR program directors in the American Association of Cardiovascular and Pulmonary Rehabilitation's database. Data collection included program characteristics, the use of specific referral and recruitment strategies, and self-reported program participation rates. Between 2007 and 2012, 49% of programs measured referral of inpatients from the hospital, 21% measured outpatient referral from office/clinic, 71% measured program enrollment, and 74% measured program completion rates. Program-reported participation rates (interquartile range) were 68% (32-90) for hospital referral, 35% (15-60) for office/clinic referral, 70% (46-80) for enrollment, and 75% (62-82) for program completion. The majority of programs utilized a hospital-based systematic referral, liaison-facilitated referral, or inpatient CR program referral (64%, 68%, and 60% of the time, respectively). Early appointments (<2 weeks) were utilized by 35%, and consistent phone call appointment reminders were utilized by 50% of programs. Quality improvement (QI) projects were performed by about half of CR programs. Measurement of participation rates was highly correlated with performing QI projects (P < .0001.) : Although programs are aware of participation rate gaps, the monitoring of participation rates is suboptimal, QI initiatives are infrequent, and proven strategies for increasing patient participation are inconsistently utilized. These issues likely contribute to the national CR participation gap and may prove to be useful targets for national QI initiatives.

  5. Water quality monitoring for high-priority water bodies in the Sonoran Desert network

    Treesearch

    Terry W. Sprouse; Robert M. Emanuel; Sara A. Strorrer

    2005-01-01

    This paper describes a network monitoring program for “high priority” water bodies in the Sonoran Desert Network of the National Park Service. Protocols were developed for monitoring selected waters for ten of the eleven parks in the Network. Park and network staff assisted in identifying potential locations of testing sites, local priorities, and how water quality...

  6. Quality assurance for respiratory care services: a computer-assisted program.

    PubMed

    Elliott, C G

    1993-01-01

    At present, the principal advantage of computer-assisted quality assurance is the acquisition of quality assurance date without resource-consuming chart reviews. A surveillance program like the medical director's alert may reduce morbidity and mortality. Previous research suggests that inadequate oxygen therapy or failures in airway management are important causes of preventable deaths in hospitals. Furthermore, preventable deaths tend to occur among patients who have lower severity-of-illness scores and who are not in ICUs. Thus, surveillance of the entire hospital, as performed by the HIS medical director's alert, may significantly impact hospital mortality related to respiratory care. Future research should critically examine the potential of such computerized systems to favorably change the morbidity and mortality of hospitalized patients. The departments of respiratory care and medical informatics at LDS Hospital have developed a computer-assisted approach to quality assurance monitoring of respiratory care services. This system provides frequent and consistent samples of a variety of respiratory care data. The immediate needs of patients are addressed through a daily surveillance system (medical director's alert). The departmental quality assurance program utilizes a separate program that monitors clinical indicators of staff performance in terms of stated departmental policies and procedures (rate-based clinical indicators). The availability of an integrated patient database allows these functions to be performed without labor-intensive chart audits.

  7. 40 CFR 52.346 - Air quality monitoring requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Air quality monitoring requirements. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.346 Air quality monitoring... VIII Administrator, the State submitted a revised Air Quality Monitoring State Implementation Plan. The...

  8. 40 CFR 52.346 - Air quality monitoring requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Air quality monitoring requirements. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.346 Air quality monitoring... VIII Administrator, the State submitted a revised Air Quality Monitoring State Implementation Plan. The...

  9. 40 CFR 52.346 - Air quality monitoring requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Air quality monitoring requirements. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.346 Air quality monitoring... VIII Administrator, the State submitted a revised Air Quality Monitoring State Implementation Plan. The...

  10. 40 CFR 52.346 - Air quality monitoring requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Air quality monitoring requirements. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.346 Air quality monitoring... VIII Administrator, the State submitted a revised Air Quality Monitoring State Implementation Plan. The...

  11. 40 CFR 52.346 - Air quality monitoring requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Air quality monitoring requirements. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.346 Air quality monitoring... VIII Administrator, the State submitted a revised Air Quality Monitoring State Implementation Plan. The...

  12. Comparison of bioimpedance analysis scan, hemoglobin and urea reduction ratio in hemodialysis patients following and not following monitoring program for improving quality of life

    NASA Astrophysics Data System (ADS)

    Muzasti, R. A.; Lubis, H. R.

    2018-03-01

    Hemodialysis (HD) is the renal replacement therapy in end-stage renal disease (ESRD), at least 2-3 times a week, impacting substantial changes in daily life. Therefore a monitoring program is needed to improve the quality of life (QoL) of HD patients. Indicators in monitoring QoL include phase angle (PhA), muscle and fat mass, and body fluid composition through Bio Scan impedance analysis (BIA) Scan, hemoglobin level, and urea reduction ratio (URR). An analytic study with the cross-sectional design was performed in 168 patients at Klinik Spesialis Ginjal Hipertensi (KSGH) Rasyida, Medan to compare BIA Scan profiles, hemoglobin levels, and URR in HD patients who follow and do not follow the monitoring program for improving QoL {Program Pemantauan Peningkatan Kualitas Hidup (P3KH)}. Each variable was analyzed by independent T-test, it is significant if p <0.05. This study showed that there were differences in BMI (p = 0.006), fat mass (p = 0.010), extracellular water / intracellular water (ECW / ICW) (p = 0.046), and haemoglobin p = 0.001). Although it was better in the program group, statistically there was no difference of PhA (p = 0.136), muscle mass (p = 0.842), and URR (p = 0.232).

  13. Event-Driven Messaging for Offline Data Quality Monitoring at ATLAS

    NASA Astrophysics Data System (ADS)

    Onyisi, Peter

    2015-12-01

    During LHC Run 1, the information flow through the offline data quality monitoring in ATLAS relied heavily on chains of processes polling each other's outputs for handshaking purposes. This resulted in a fragile architecture with many possible points of failure and an inability to monitor the overall state of the distributed system. We report on the status of a project undertaken during the LHC shutdown to replace the ad hoc synchronization methods with a uniform message queue system. This enables the use of standard protocols to connect processes on multiple hosts; reliable transmission of messages between possibly unreliable programs; easy monitoring of the information flow; and the removal of inefficient polling-based communication.

  14. Water Quality Monitoring Manual.

    ERIC Educational Resources Information Center

    Mason, Fred J.; Houdart, Joseph F.

    This manual is designed for students involved in environmental education programs dealing with water pollution problems. By establishing a network of Environmental Monitoring Stations within the educational system, four steps toward the prevention, control, and abatement of water pollution are proposed. (1) Train students to recognize, monitor,…

  15. A national clinical quality program for Veterans Affairs catheterization laboratories (from the Veterans Affairs clinical assessment, reporting, and tracking program).

    PubMed

    Maddox, Thomas M; Plomondon, Mary E; Petrich, Megan; Tsai, Thomas T; Gethoffer, Hans; Noonan, Gregory; Gillespie, Brian; Box, Tamara; Fihn, Stephen D; Jesse, Robert L; Rumsfeld, John S

    2014-12-01

    A "learning health care system", as outlined in a recent Institute of Medicine report, harnesses real-time clinical data to continuously measure and improve clinical care. However, most current efforts to understand and improve the quality of care rely on retrospective chart abstractions complied long after the provision of clinical care. To align more closely with the goals of a learning health care system, we present the novel design and initial results of the Veterans Affairs (VA) Clinical Assessment, Reporting, and Tracking (CART) program-a national clinical quality program for VA cardiac catheterization laboratories that harnesses real-time clinical data to support clinical care and quality-monitoring efforts. Integrated within the VA electronic health record, the CART program uses a specialized software platform to collect real-time patient and procedural data for all VA patients undergoing coronary procedures in VA catheterization laboratories. The program began in 2005 and currently contains data on 434,967 catheterization laboratory procedures, including 272,097 coronary angiograms and 86,481 percutaneous coronary interventions, performed by 801 clinicians on 246,967 patients. We present the initial data from the CART program and describe 3 quality-monitoring programs that use its unique characteristics-procedural and complications feedback to individual labs, coronary device surveillance, and major adverse event peer review. The VA CART program is a novel approach to electronic health record design that supports clinical care, quality, and safety in VA catheterization laboratories. Its approach holds promise in achieving the goals of a learning health care system. Published by Elsevier Inc.

  16. Patterns of water-quality variability in San Francisco Bay during the first six years of the regional monitoring program, 1993-1998

    USGS Publications Warehouse

    Cloern, J.E.; Cole, B.E.; Edmunds, J.L.; Schraga, T.S.; Arnsberg, A.

    2000-01-01

    Monitoring Results presents data from the Status and Trends portion of the 1998 San Francisco Estuary Regional Monitoring Program for Trace Substances (RMP). A list of reports on Pilot and Special Studies, as well as other RMP related activities can be found at the end of this document. These reports provide perspective and insight on important contaminant issues identified by the RMP, and they describe results from projects that took advantage of RMP field operations. For a summary of the conditions of the Estuary see The Pulse . A print copy may also be ordered by contacting the San Francisco Estuary Institute (SFEI). In 1998, the San Francisco Regional Water Quality Control Board (Regional Board) and seventy-three federal, state, and local agencies and companies participated in the RMP as funders and service providers (Table 1.1). Participants also assist in directing the Program through input or participation on the Steering and Technical Review Committees. The RMP’s overall goal is to provide data and interpretation that helps to address certain information needs of the Regional Board. In general, these efforts fall under five major objectives which provide a framework for efforts to respond to more specific management questions. 1. Describe patterns and trends in contaminant concentration and distribution. 2. Describe general sources and loadings of contamination to the Estuary. 3. Measure contaminant effects on selected parts of the Estuary ecosystem. 4. Compare monitoring information to relevant water quality objectives and other guidelines. 5. Synthesize and distribute information from a range of sources to present a more complete picture of the sources, distribution, fates, and effects of contaminants in the Estuary ecosystem.

  17. 40 CFR 264.99 - Compliance monitoring program.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... be based on a compliance monitoring program developed to meet the requirements of this section. (i... 40 Protection of Environment 26 2011-07-01 2011-07-01 false Compliance monitoring program. 264.99... Releases From Solid Waste Management Units § 264.99 Compliance monitoring program. An owner or operator...

  18. Air Quality Monitor

    NASA Technical Reports Server (NTRS)

    1996-01-01

    The Stak-Tracker CEM (Continuous Emission Monitor) Gas Analyzer is an air quality monitor capable of separating the various gases in a bulk exhaust stream and determining the amounts of individual gases present within the stream. The monitor is produced by GE Reuter- Stokes, a subsidiary of GE Corporate Research & Development Center. The Stak-Tracker uses a Langley Research Center software package which measures the concentration of a target gas by determining the degree to which molecules of that gas absorb an infrared beam. The system is environmental-friendly, fast and has relatively low installation and maintenance costs. It is applicable to gas turbines and various industries including glass, paper and cement.

  19. ECONOMICS OF SAMPLE COMPOSITING AS A SCREENING TOOL IN GROUND WATER QUALITY MONITORING

    EPA Science Inventory

    Recent advances in high throughput/automated compositing with robotics/field-screening methods offer seldom-tapped opportunities for achieving cost-reduction in ground water quality monitoring programs. n economic framework is presented in this paper for the evaluation of sample ...

  20. To What Extent is Drinking Water Tested in Sub-Saharan Africa? A Comparative Analysis of Regulated Water Quality Monitoring.

    PubMed

    Peletz, Rachel; Kumpel, Emily; Bonham, Mateyo; Rahman, Zarah; Khush, Ranjiv

    2016-03-02

    Water quality information is important for guiding water safety management and preventing water-related diseases. To assess the current status of regulated water quality monitoring in sub-Saharan Africa, we evaluated testing programs for fecal contamination in 72 institutions (water suppliers and public health agencies) across 10 countries. Data were collected through written surveys, in-person interviews, and analysis of microbial water quality testing levels. Though most institutions did not achieve the testing levels specified by applicable standards or World Health Organization (WHO) Guidelines, 85% of institutions had conducted some microbial water testing in the previous year. Institutions were more likely to meet testing targets if they were suppliers (as compared to surveillance agencies), served larger populations, operated in urban settings, and had higher water quality budgets (all p < 0.05). Our results indicate that smaller water providers and rural public health offices will require greater attention and additional resources to achieve regulatory compliance for water quality monitoring in sub-Saharan Africa. The cost-effectiveness of water quality monitoring should be improved by the application of risk-based water management approaches. Efforts to strengthen monitoring capacity should pay greater attention to program sustainability and institutional commitment to water safety.

  1. Ecological Monitoring and Compliance Program 2007 Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hansen, Dennis; Anderson, David; Derek, Hall

    2008-03-01

    In accordance with U.S. Department of Energy (DOE) Order 450.1, 'Environmental Protection Program', the Office of the Assistant Manager for Environmental Management of the DOE, National Nuclear Security Administration Nevada Site Office (NNSA/NSO) requires ecological monitoring and biological compliance support for activities and programs conducted at the Nevada Test Site (NTS). National Security Technologies, LLC (NSTec), Ecological Services has implemented the Ecological Monitoring and Compliance (EMAC) Program to provide this support. EMAC is designed to ensure compliance with applicable laws and regulations, delineate and define NTS ecosystems, and provide ecological information that can be used to predict and evaluate themore » potential impacts of proposed projects and programs on those ecosystems. This report summarizes the EMAC activities conducted by NSTec during calendar year 2007. Monitoring tasks during 2007 included eight program areas: (a) biological surveys, (b) desert tortoise compliance, (c) ecosystem mapping and data management, (d) sensitive plant monitoring, (e) sensitive and protected/regulated animal monitoring, (f) habitat monitoring, (g) habitat restoration monitoring, and (h) biological monitoring at the Nonproliferation Test and Evaluation Complex (NPTEC). The following sections of this report describe work performed under these eight areas.« less

  2. Automated monitoring of recovered water quality

    NASA Technical Reports Server (NTRS)

    Misselhorn, J. E.; Hartung, W. H.; Witz, S. W.

    1974-01-01

    Laboratory prototype water quality monitoring system provides automatic system for online monitoring of chemical, physical, and bacteriological properties of recovered water and for signaling malfunction in water recovery system. Monitor incorporates whenever possible commercially available sensors suitably modified.

  3. Assessment of Water-Quality Monitoring and a Proposed Water-Quality Monitoring Network for the Mosquito Lagoon Basin, East-Central Florida

    USGS Publications Warehouse

    Kroening, Sharon E.

    2008-01-01

    Surface- and ground-water quality data from the Mosquito Lagoon Basin were compiled and analyzed to: (1) describe historical and current monitoring in the basin, (2) summarize surface- and ground-water quality conditions with an emphasis on identifying areas that require additional monitoring, and (3) develop a water-quality monitoring network to meet the goals of Canaveral National Seashore (a National Park) and to fill gaps in current monitoring. Water-quality data were compiled from the U.S. Environmental Protection Agency's STORET system, the U.S. Geological Survey's National Water Information System, or from the agency which collected the data. Most water-quality monitoring focused on assessing conditions in Mosquito Lagoon. Significant spatial and/or seasonal variations in water-quality constituents in the lagoon were quantified for pH values, fecal coliform bacteria counts, and concentrations of dissolved oxygen, total nitrogen, total phosphorus, chlorophyll-a, and total suspended solids. Trace element, pesticide, and ground-water-quality data were more limited. Organochlorine insecticides were the major class of pesticides analyzed. A surface- and ground-water-quality monitoring network was designed for the Mosquito Lagoon Basin which emphasizes: (1) analysis of compounds indicative of human activities, including pesticides and other trace organic compounds present in domestic and industrial waste; (2) greater data collection in the southern part of Mosquito Lagoon where spatial variations in water-quality constituents were quantified; and (3) additional ground-water-quality data collection in the surficial aquifer system and Upper Floridan aquifer. Surface-water-quality data collected as part of this network would include a fixed-station monitoring network of eight sites in the southern part of the basin, including a canal draining Oak Hill. Ground-water quality monitoring should be done routinely at about 20 wells in the surficial aquifer system and Upper

  4. Ecological Monitoring and Compliance Program 2011 Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hansen, D. J.; Anderson, D. C.; Hall, D. B.

    The Ecological Monitoring and Compliance (EMAC) Program, funded through the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office, monitors the ecosystem of the Nevada National Security Site and ensures compliance with laws and regulations pertaining to NNSS biota. This report summarizes the program's activities conducted by National Security Technologies, LLC, during calendar year 2011. Program activities included (a) biological surveys at proposed construction sites, (b) desert tortoise compliance, (c) ecosystem monitoring, (d) sensitive plant species monitoring, (e) sensitive and protected/regulated animal monitoring, (f) habitat restoration monitoring, and (g) monitoring of the Nonproliferation Test and Evaluation Complex. Duringmore » 2011, all applicable laws, regulations, and permit requirements were met, enabling EMAC to achieve its intended goals and objectives.« less

  5. Quality-control issues on high-resolution diagnostic monitors.

    PubMed

    Parr, L F; Anderson, A L; Glennon, B K; Fetherston, P

    2001-06-01

    Previous literature indicates a need for more data collection in the area of quality control of high-resolution diagnostic monitors. Throughout acceptance testing, which began in June 2000, stability of monitor calibration was analyzed. Although image quality on all monitors was found to be acceptable upon initial acceptance testing using VeriLUM software by Image Smiths, Inc (Germantown, MD), it was determined to be unacceptable during the clinical phase of acceptance testing. High-resolution monitors were evaluated for quality assurance on a weekly basis from installation through acceptance testing and beyond. During clinical utilization determination (CUD), monitor calibration was identified as a problem and the manufacturer returned and recalibrated all workstations. From that time through final acceptance testing, high-resolution monitor calibration and monitor failure rate remained a problem. The monitor vendor then returned to the site to address these areas. Monitor defocus was still noticeable and calibration checks were increased to three times per week. White and black level drift on medium-resolution monitors had been attributed to raster size settings. Measurements of white and black level at several different size settings were taken to determine the effect of size on white and black level settings. Black level remained steady with size change. White level appeared to increase by 2.0 cd/m2 for every 0.1 inches decrease in horizontal raster size. This was determined not to be the cause of the observed brightness drift. Frequency of calibration/testing is an issue in a clinical environment. The increased frequency required at our site cannot be sustained. The medical physics division cannot provide dedicated personnel to conduct the quality-assurance testing on all monitors at this interval due to other physics commitments throughout the hospital. Monitor access is also an issue due to radiologists' need to read images. Some workstations are in use 7 AM

  6. Psychosocial Correlates of Clinicians' Prescription Drug Monitoring Program Utilization.

    PubMed

    Pugliese, John A; Wintemute, Garen J; Henry, Stephen G

    2018-05-01

    The purpose of this study is to extend prior research on barriers to use of a prescription drug monitoring program by examining psychosocial correlates of intended use among physicians and pharmacists. Overall, 1,904 California physicians and pharmacists responded to a statewide survey (24.1% response rate) from August 2016 to January 2017. Participants completed an online survey examining attitudes toward prescription drug misuse and abuse, prescribing practices, prescription drug monitoring program design and ease of use, professional obligations, and normative beliefs regarding prescription drug monitoring program use. Data were analyzed in 2017. Perceived prescription drug monitoring program usefulness and normative beliefs fully mediated the relationship between concern about prescription drug abuse and intentions to use the prescription drug monitoring program. Clinicians' sense of professional and moral obligation to use the prescription drug monitoring program was unrelated to intention to use the prescription drug monitoring program despite a positive relationship with concern about misuse and abuse. Compared with physicians, pharmacists reported greater concern about prescription drug misuse, greater professional and moral obligation to use prescription drug monitoring program, and greater rating of prescription drug monitoring program usefulness. Interventions that target normative beliefs surrounding prescription drug monitoring program use and how to use prescription drug monitoring programs effectively are likely to be more effective than those that target professional obligations or moralize to the medical community. Published by Elsevier Inc.

  7. Los Alamos National Laboratory Meteorology Monitoring Program: 2016 Data Completeness/ Quality Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bruggeman, David Alan

    This report summarizes data completeness by tower and by instrument for 2016 and compares that data with the Los Alamos National Laboratory (LANL) and American National Standards Institute (ANSI) 2015 standards. This report is designed to make data users aware of data completeness and any data quality issues. LANL meteorology monitoring goals include 95% completeness for all measurements. The ANSI 2015 standard requires 90% completeness for all measurements. This report documents instrument/tower issues as they impact data completeness.

  8. Summary of the major water-quality findings from the Eastern Iowa Basins study unit of the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Kalkhoff, Stephen J.

    2000-01-01

    Results from the EIWA NAWQA study build on previous and ongoing research and water-quality monitoring programs in Iowa and provide new insights into the relation between the quality of the State's water resources and human activities. The major findings from the study are listed below.

  9. Air Quality Monitoring and Sensor Technologies

    EPA Pesticide Factsheets

    EPA scientist Ron Williams presented on the features, examination, application, examples, and data quality of continuous monitoring study designs at EPA's Community Air Monitoring Training in July 2015.

  10. Quality Assurance Through Quality Improvement and Professional Development in the National Breast and Cervical Cancer Early Detection Program

    PubMed Central

    Siegl, Elvira J.; Miller, Jacqueline W.; Khan, Kris; Harris, Susan E.

    2015-01-01

    Quality assurance (QA) is the process of providing evidence that the outcome meets the established standards. Quality improvement (QI), by contrast, is the act of methodically developing ways to meet acceptable quality standards and evaluating current processes to improve overall performance. In the case of the National Breast and Cervical Cancer Early Detection Program (NBCCEDP), the desired outcome is the delivery of quality health care services to program clients. The NBCCEDP provides professional development to ensure that participating providers have current knowledge of evidence-based clinical standards regarding breast and cervical cancer screening and diagnosis and are monitoring women with abnormal screening results for timely follow-up. To assess the quality of clinical care provided to NBCCEDP clients, performance data are collected by NBCCEDP grantees and compared against predetermined Centers for Disease Control and Prevention (CDC) benchmarks known as Data Quality Indicator Guides. In this article, the authors describe 1) the development and use of indicators for QI in the NBCCEDP and 2) the professional development activities implemented to improve clinical outcomes. QA identifies problems, whereas QI systematically corrects them. The quality of service delivery and improved patient outcomes among NBCCEDP grantees has enhanced significantly because of continuous monitoring of performance and professional development. By using QA, NBCCEDP grantees can maximize the quality of patient screening, diagnostic services, and follow-up. Examples of grantee activities to maintain quality of care are also described in this report. PMID:25099901

  11. SU-F-R-11: Designing Quality and Safety Informatics Through Implementation of a CT Radiation Dose Monitoring Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilson, JM; Samei, E; Departments of Physics, Electrical and Computer Engineering, and Biomedical Engineering, and Medical Physics Graduate Program, Duke University, Durham, NC

    2016-06-15

    Purpose: Recent legislative and accreditation requirements have driven rapid development and implementation of CT radiation dose monitoring solutions. Institutions must determine how to improve quality, safety, and consistency of their clinical performance. The purpose of this work was to design a strategy and meaningful characterization of results from an in-house, clinically-deployed dose monitoring solution. Methods: A dose monitoring platform was designed by our imaging physics group that focused on extracting protocol parameters, dose metrics, and patient demographics and size. Compared to most commercial solutions, which focus on individual exam alerts and global thresholds, the program sought to characterize overall consistencymore » and targeted thresholds based on eight analytic interrogations. Those were based on explicit questions related to protocol application, national benchmarks, protocol and size-specific dose targets, operational consistency, outliers, temporal trends, intra-system variability, and consistent use of electronic protocols. Using historical data since the start of 2013, 95% and 99% intervals were used to establish yellow and amber parameterized dose alert thresholds, respectively, as a function of protocol, scanner, and size. Results: Quarterly reports have been generated for three hospitals for 3 quarters of 2015 totaling 27880, 28502, 30631 exams, respectively. Four adult and two pediatric protocols were higher than external institutional benchmarks. Four protocol dose levels were being inconsistently applied as a function of patient size. For the three hospitals, the minimum and maximum amber outlier percentages were [1.53%,2.28%], [0.76%,1.8%], [0.94%,1.17%], respectively. Compared with the electronic protocols, 10 protocols were found to be used with some inconsistency. Conclusion: Dose monitoring can satisfy requirements with global alert thresholds and patient dose records, but the real value is in optimizing patient

  12. Improving and monitoring air quality.

    PubMed

    DuPont, André

    2018-05-01

    Since the authorization of the Clean Air Act Amendments of 1990, the air quality in the USA has significantly improved because of strong public support. The lessons learned over the last 25 years are being shared with the policy analysts, technical professionals, and scientist who endeavor to improve air quality in their communities. This paper will review how the USA has achieved the "high" standard of air quality that was envisioned in the early 1990s. This document will describe SO 2 gas emission reduction technology and highlight operation of emission monitoring technology. This paper describes the basic process operation of an air pollution control scrubber. A technical review of measures required to operate and maintain a large-scale pollution control system will be described. Also, the author explains how quality assurance procedures in performance of continuous emission monitoring plays a significant role in reducing air pollution.

  13. Portable water quality monitoring system

    NASA Astrophysics Data System (ADS)

    Nizar, N. B.; Ong, N. R.; Aziz, M. H. A.; Alcain, J. B.; Haimi, W. M. W. N.; Sauli, Z.

    2017-09-01

    Portable water quality monitoring system was a developed system that tested varied samples of water by using different sensors and provided the specific readings to the user via short message service (SMS) based on the conditions of the water itself. In this water quality monitoring system, the processing part was based on a microcontroller instead of Lead and Copper Rule (LCR) machines to receive the results. By using four main sensors, this system obtained the readings based on the detection of the sensors, respectively. Therefore, users can receive the readings through SMS because there was a connection between Arduino Uno and GSM Module. This system was designed to be portable so that it would be convenient for users to carry it anywhere and everywhere they wanted to since the processor used is smaller in size compared to the LCR machines. It was also developed to ease the user to monitor and control the water quality. However, the ranges of the sensors' detection still a limitation in this study.

  14. A Prototype Educational Delivery System Using Water Quality Monitoring as a Model.

    ERIC Educational Resources Information Center

    Glazer, Richard B.

    This report describes the model educational delivery system used by Ulster County Community College in its water quality monitoring program. The educational delivery system described in the report encompasses the use of behavioral objectives as its foundation and builds upon this foundation to form a complete system whose outcomes can be measured,…

  15. Ambient Monitoring Technology Information Center (AMTIC)

    EPA Pesticide Factsheets

    This site contains information on ambient air quality monitoring programs, monitoring methods, quality assurance and control procedures, and federal regulations related to ambient air quality monitoring.

  16. To What Extent is Drinking Water Tested in Sub-Saharan Africa? A Comparative Analysis of Regulated Water Quality Monitoring

    PubMed Central

    Peletz, Rachel; Kumpel, Emily; Bonham, Mateyo; Rahman, Zarah; Khush, Ranjiv

    2016-01-01

    Water quality information is important for guiding water safety management and preventing water-related diseases. To assess the current status of regulated water quality monitoring in sub-Saharan Africa, we evaluated testing programs for fecal contamination in 72 institutions (water suppliers and public health agencies) across 10 countries. Data were collected through written surveys, in-person interviews, and analysis of microbial water quality testing levels. Though most institutions did not achieve the testing levels specified by applicable standards or World Health Organization (WHO) Guidelines, 85% of institutions had conducted some microbial water testing in the previous year. Institutions were more likely to meet testing targets if they were suppliers (as compared to surveillance agencies), served larger populations, operated in urban settings, and had higher water quality budgets (all p < 0.05). Our results indicate that smaller water providers and rural public health offices will require greater attention and additional resources to achieve regulatory compliance for water quality monitoring in sub-Saharan Africa. The cost-effectiveness of water quality monitoring should be improved by the application of risk-based water management approaches. Efforts to strengthen monitoring capacity should pay greater attention to program sustainability and institutional commitment to water safety. PMID:26950135

  17. Design and implementation air quality monitoring robot

    NASA Astrophysics Data System (ADS)

    Chen, Yuanhua; Li, Jie; Qi, Chunxue

    2017-01-01

    Robot applied in environmental protection can break through the limitations in working environment, scope and mode of the existing environmental monitoring and pollution abatement equipments, which undertake the innovation and improvement in the basin, atmosphere, emergency and pollution treatment facilities. Actually, the relevant technology is backward with limited research and investment. Though the device companies have achieved some results in the study on the water quality monitoring, pipeline monitoring and sewage disposal, this technological progress on the whole is still much slow, and the mature product has not been formed. As a result, the market urges a demand of a new type of device which is more suitable for environmental protection on the basis of robot successfully applied in other fields. This paper designs and realizes a tracked mobile robot of air quality monitoring, which can be used to monitor air quality for the pollution accident in industrial parks and regular management.

  18. Correlates of quality educational programs.

    PubMed

    Chester, Deborah R; Tracy, Jessamyn A; Earp, Emily; Chauhan, Reetu

    2002-06-01

    Preliminary evaluation findings are presented that explore relationships between educational program quality and program characteristics such as program type, security level, aftercare, teacher certification, facility size, and private versus public provider. Several program characteristics are found to be related to measurements of educational program quality. Among the major quality characteristics are proportion of program teachers that are professionally certified, smaller sized facilities versus larger facilities, level of aftercare services, and provider sources, with private for-profit providers being the lowest performing and public providers being the highest performing. The article closes with description of the Juvenile Justice Educational Enhancement Program's continuing evaluation of correlates to educational program quality through the continued development of a comprehensive database.

  19. Progress and lessons learned from water-quality monitoring networks

    USGS Publications Warehouse

    Myers, Donna N.; Ludtke, Amy S.

    2017-01-01

    Stream-quality monitoring networks in the United States were initiated and expanded after passage of successive federal water-pollution control laws from 1948 to 1972. The first networks addressed information gaps on the extent and severity of stream pollution and served as early warning systems for spills. From 1965 to 1972, monitoring networks expanded to evaluate compliance with stream standards, track emerging issues, and assess water-quality status and trends. After 1972, concerns arose regarding the ability of monitoring networks to determine if water quality was getting better or worse and why. As a result, monitoring networks adopted a hydrologic systems approach targeted to key water-quality issues, accounted for human and natural factors affecting water quality, innovated new statistical methods, and introduced geographic information systems and models that predict water quality at unmeasured locations. Despite improvements, national-scale monitoring networks have declined over time. Only about 1%, or 217, of more than 36,000 US Geological Survey monitoring sites sampled from 1975 to 2014 have been operated throughout the four decades since passage of the 1972 Clean Water Act. Efforts to sustain monitoring networks are important because these networks have collected information crucial to the description of water-quality trends over time and are providing information against which to evaluate future trends.

  20. National-Scale Air Quality Data Assessment: Initial Findings from the Near-Road NO2 Monitoring Program

    NASA Astrophysics Data System (ADS)

    DeWinter, J. L.

    2015-12-01

    In 2010, the U.S. Environmental Protection Agency (EPA) revised the National Ambient Air Quality Standards (NAAQS) for nitrogen dioxide (NO2) to include a primary health-based standard for hourly NO2. NO2 is a reactive gas that is emitted from motor vehicles, such as cars, trucks, and off-road equipment, as well as non-mobile sources, and is known to adversely affect human respiratory health. In conjunction with the NAAQS revision, EPA has mandated air quality monitoring next to selected major roadways throughout the United States that are in large urban areas where peak hourly NO2 concentrations are expected. Monitoring began in phases during 2012-2015 and included nitrogen dioxide (NO2), carbon monoxide (CO), and particulate matter smaller than 2.5 microns (PM2.5) at 40 monitoring sites nationwide. We conducted a national-scale review of near-road air pollutant concentrations, identified areas where high concentrations of NO2, PM2.5, and CO occurred, and evaluated how concentrations varied by factors such as location, distance to roadway, fleet mix characteristics, and traffic volume. We present the findings from our national near-road data assessment for the 2014 monitoring year.

  1. Importance of Data Management in a Long-Term Biological Monitoring Program

    NASA Astrophysics Data System (ADS)

    Christensen, Sigurd W.; Brandt, Craig C.; McCracken, Mary K.

    2011-06-01

    The long-term Biological Monitoring and Abatement Program (BMAP) has always needed to collect and retain high-quality data on which to base its assessments of ecological status of streams and their recovery after remediation. Its formal quality assurance, data processing, and data management components all contribute to meeting this need. The Quality Assurance Program comprehensively addresses requirements from various institutions, funders, and regulators, and includes a data management component. Centralized data management began a few years into the program when an existing relational database was adapted and extended to handle biological data. The database's main data tables and several key reference tables are described. One of the most important related activities supporting long-term analyses was the establishing of standards for sampling site names, taxonomic identification, flagging, and other components. The implemented relational database supports the transmittal of data to the Oak Ridge Environmental Information System (OREIS) as the permanent repository. We also discuss some limitations to our implementation. Some types of program data were not easily accommodated in the central systems, and many possible data-sharing and integration options are not easily accessible to investigators. From our experience we offer data management advice to other biologically oriented long-term environmental sampling and analysis programs.

  2. Comprehensive Monitoring Program. Air Quality Data Assessment for 1989. Version 2.1. Volume 2

    DTIC Science & Technology

    1990-06-01

    Hg collected on Hopcalite TH media. 4.4.3.2 Basin F Data. Table 4.4-5 shows average and maximum metals values for the Basin F Remedial Monitoring...PMRMA. "Chemical Quality Assurance Plan." Version 1.0, July, 1989. Rathje and Marcero. 1976. "Improved Hopcalite Procedure for the Determination of

  3. Using business intelligence to monitor clinical quality metrics.

    PubMed

    Resetar, Ervina; Noirot, Laura A; Reichley, Richard M; Storey, Patricia; Skiles, Ann M; Traynor, Patrick; Dunagan, W Claiborne; Bailey, Thomas C

    2007-10-11

    BJC HealthCare (BJC) uses a number of industry standard indicators to monitor the quality of services provided by each of its hospitals. By establishing an enterprise data warehouse as a central repository of clinical quality information, BJC is able to monitor clinical quality performance in a timely manner and improve clinical outcomes.

  4. Overview of the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Leahy, P.P.; Thompson, T.H.

    1994-01-01

    The Nation's water resources are the basis for life and our economic vitality. These resources support a complex web of human activities and fishery and wildlife needs that depend upon clean water. Demands for good-quality water for drinking, recreation, farming, and industry are rising, and as a result, the American public is concerned about the condition and sustainability of our water resources. The American public is asking: Is it safe to swim in and drink water from our rivers or lakes? Can we eat the fish that come from them? Is our ground water polluted? Is water quality degrading with time, and if so, why? Has all the money we've spent to clean up our waters, done any good? The U.S. Geological Survey's National Water-Quality Assessment (NAWQA) Program was designed to provide information that will help answer these questions. NAWQA is designed to assess historical, current, and future water-quality conditions in representative river basins and aquifers nationwide. One of the primary objectives of the program is to describe relations between natural factors, human activities, and water-quality conditions and to define those factors that most affect water quality in different parts of the Nation. The linkage of water quality to environmental processes is of fundamental importance to water-resource managers, planners, and policy makers. It provides a strong and unbiased basis for better decisionmaking by those responsible for making decisions that affect our water resources, including the United States Congress, Federal, State, and local agencies, environmental groups, and industry. Information from the NAWQA Program also will be useful for guiding research, monitoring, and regulatory activities in cost effective ways.

  5. Importance of Data Management in a Long-term Biological Monitoring Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christensen, Sigurd W; Brandt, Craig C; McCracken, Kitty

    2011-01-01

    The long-term Biological Monitoring and Abatement Program (BMAP) has always needed to collect and retain high-quality data on which to base its assessments of ecological status of streams and their recovery after remediation. Its formal quality assurance, data processing, and data management components all contribute to this need. The Quality Assurance Program comprehensively addresses requirements from various institutions, funders, and regulators, and includes a data management component. Centralized data management began a few years into the program. An existing relational database was adapted and extended to handle biological data. Data modeling enabled the program's database to process, store, and retrievemore » its data. The data base's main data tables and several key reference tables are described. One of the most important related activities supporting long-term analyses was the establishing of standards for sampling site names, taxonomic identification, flagging, and other components. There are limitations. Some types of program data were not easily accommodated in the central systems, and many possible data-sharing and integration options are not easily accessible to investigators. The implemented relational database supports the transmittal of data to the Oak Ridge Environmental Information System (OREIS) as the permanent repository. From our experience we offer data management advice to other biologically oriented long-term environmental sampling and analysis programs.« less

  6. Proposed comprehensive ototoxicity monitoring program for VA healthcare (COMP-VA)

    PubMed Central

    Konrad-Martin, Dawn; Reavis, Kelly M.; McMillan, Garnett; Helt, Wendy J.; Dille, Marilyn

    2015-01-01

    Prevention and rehabilitation of hearing loss and tinnitus, the two most commonly awarded service-connected disabilities, are high priority initiatives in the Department of Veterans Affairs (VA). At least 4,000 Veterans, most with significant hearing loss, will receive cisplatin this year, with more than half sustaining permanent hearing shift and nearly 40% developing new tinnitus. With improved survivability following cancer treatment, Veterans treated with cisplatin are approached with the dual goals of effective treatment and preserved quality of life. This article describes COMP-VA, a comprehensive ototoxicity monitoring program developed for VA patients receiving cisplatin. The program includes an individualized pretreatment prediction model that identifies the likelihood of hearing shift given cisplatin dose and patient factors. It supports both manual and automated hearing testing with a newly developed portable audiometer capable of performing the recommended procedures on the chemotherapy unit during treatment. It also includes objective methods for identifying outer hair cell changes and predicting audiogram changes using distortion-product otoacoustic emissions. We describe this program of evidence-based ototoxicity monitoring protocols using a case example to give the reader an understanding of how this program would be applied, along with a plan for future work to accomplish the final stages of program development. PMID:24805896

  7. Baby-MONITOR: A Composite Indicator of NICU Quality

    PubMed Central

    Kowalkowski, Marc A.; Zupancic, John A. F.; Pietz, Kenneth; Richardson, Peter; Draper, David; Hysong, Sylvia J.; Thomas, Eric J.; Petersen, Laura A.; Gould, Jeffrey B.

    2014-01-01

    BACKGROUND AND OBJECTIVES: NICUs vary in the quality of care delivered to very low birth weight (VLBW) infants. NICU performance on 1 measure of quality only modestly predicts performance on others. Composite measurement of quality of care delivery may provide a more comprehensive assessment of quality. The objective of our study was to develop a robust composite indicator of quality of NICU care provided to VLBW infants that accurately discriminates performance among NICUs. METHODS: We developed a composite indicator, Baby-MONITOR, based on 9 measures of quality chosen by a panel of experts. Measures were standardized, equally weighted, and averaged. We used the California Perinatal Quality Care Collaborative database to perform across-sectional analysis of care given to VLBW infants between 2004 and 2010. Performance on the Baby-MONITOR is not an absolute marker of quality but indicates overall performance relative to that of the other NICUs. We used sensitivity analyses to assess the robustness of the composite indicator, by varying assumptions and methods. RESULTS: Our sample included 9023 VLBW infants in 22 California regional NICUs. We found significant variations within and between NICUs on measured components of the Baby-MONITOR. Risk-adjusted composite scores discriminated performance among this sample of NICUs. Sensitivity analysis that included different approaches to normalization, weighting, and aggregation of individual measures showed the Baby-MONITOR to be robust (r = 0.89–0.99). CONCLUSIONS: The Baby-MONITOR may be a useful tool to comprehensively assess the quality of care delivered by NICUs. PMID:24918221

  8. WSN based indoor air quality monitoring in classrooms

    NASA Astrophysics Data System (ADS)

    Wang, S. K.; Chew, S. P.; Jusoh, M. T.; Khairunissa, A.; Leong, K. Y.; Azid, A. A.

    2017-03-01

    Indoor air quality monitoring is essential as the human health is directly affected by indoor air quality. This paper presents the investigations of the impact of undergraduate students' concentration during lecture due to the indoor air quality in classroom. Three environmental parameters such as temperature, relative humidity and concentration of carbon dioxide are measured using wireless sensor network based air quality monitoring system. This simple yet reliable system is incorporated with DHT-11 and MG-811 sensors. Two classrooms were selected to install the monitoring system. The level of indoor air quality were measured and students' concentration was assessed using intelligent test during normal lecturing section. The test showed significant correlation between the collected environmental parameters and the students' level of performances in their study.

  9. The Modular Borehole Monitoring Program. A research program to optimize well-based monitoring for geologic carbon sequestration

    DOE PAGES

    Freifeld, Barry; Daley, Tom; Cook, Paul; ...

    2014-12-31

    Understanding the impacts caused by injection of large volumes of CO 2 in the deep subsurface necessitates a comprehensive monitoring strategy. While surface-based and other remote geophysical methods can provide information on the general morphology of a CO 2 plume, verification of the geochemical conditions and validation of the remote sensing data requires measurements from boreholes that penetrate the storage formation. Unfortunately, the high cost of drilling deep wellbores and deploying instrumentation systems constrains the number of dedicated monitoring borings as well as limits the technologies that can be incorporated in a borehole completion. The objective of the Modular Boreholemore » Monitoring (MBM) Program was to develop a robust suite of well-based tools optimized for subsurface monitoring of CO 2 that could meet the needs of a comprehensive well-based monitoring program. It should have enough flexibility to be easily reconfigured for various reservoir geometries and geologies. The MBM Program sought to provide storage operators with a turn-key fully engineered design that incorporated key technologies, function over the decades long time-span necessary for post-closure reservoir monitoring, and meet industry acceptable risk profiles for deep-well installations. While still within the conceptual design phase of the MBM program, the SECARB Anthropogenic Test in Citronelle, Alabama, USA was identified as a deployment site for our engineered monitoring systems. The initial step in designing the Citronelle MBM system was to down-select from the various monitoring tools available to include technologies that we considered essential to any program. Monitoring methods selected included U-tube geochemical sampling, discrete quartz pressure and temperature gauges, an integrated fibre-optic bundle consisting of distributed temperature and heat-pulse sensing, and a sparse string of conventional 3C-geophones. While not originally planned within the initial

  10. Georgia's Stream-Water-Quality Monitoring Network, 2006

    USGS Publications Warehouse

    Nobles, Patricia L.; ,

    2006-01-01

    The USGS stream-water-quality monitoring network for Georgia is an aggregation of smaller networks and individual monitoring stations that have been established in cooperation with Federal, State, and local agencies. These networks collectively provide data from 130 sites, 62 of which are monitored continuously in real time using specialized equipment that transmits these data via satellite to a centralized location for processing and storage. These data are made available on the Web in near real time at http://waterdata.usgs.gov/ga/nwis/ Ninety-eight stations are sampled periodically for a more extensive suite of chemical and biological constituents that require laboratory analysis. Both the continuous and the periodic water-quality data are archived and maintained in the USGS National Water Information System and are available to cooperators, water-resource managers, and the public. The map at right shows the USGS stream-water-quality monitoring network for Georgia and major watersheds. The network represents an aggregation of smaller networks and individual monitoring stations that collectively provide data from 130 sites.

  11. Ecological Monitoring and Compliance Program 2008 Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hansen, Dennis J.; Anderson, David C.; Hall, Derek B.

    2009-04-30

    The Ecological Monitoring and Compliance Program, funded through the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO), monitors the ecosystem of the Nevada Test Site (NTS) and ensures compliance with laws and regulations pertaining to NTS biota. This report summarizes the program’s activities conducted by National Security Technologies, LLC (NSTec), during calendar year 2008. Program activities included (a) biological surveys at proposed construction sites, (b) desert tortoise compliance, (c) ecosystem mapping and data management, (d) sensitive plant species monitoring, (e) sensitive and protected/regulated animal monitoring, (f) habitat monitoring, (g) habitat restoration monitoring, and (h) monitoring ofmore » the Nonproliferation Test and Evaluation Complex (NPTEC).« less

  12. California Groundwater Ambient Monitoring and Assessment (GAMA) Program Priority Basin Project--shallow aquifer assessment

    USGS Publications Warehouse

    ,

    2013-01-01

    The California State Water Resources Control Board’s (SWRCB) GAMA Program is a comprehensive assessment of statewide groundwater quality in California. From 2004 to 2012, the GAMA Program’s Priority Basin Project focused on assessing groundwater resources used for public drinking-water supplies. More than 2,000 public-supply wells were sampled by U.S. Geological Survey (USGS) for this effort. Starting in 2012, the GAMA Priority Basin Project began an assessment of water resources in shallow aquifers in California. These shallow aquifers provide water for domestic and small community-supply wells, which are often drilled to shallower depths in the groundwater system than public-supply wells. Shallow aquifers are of interest because shallow groundwater may respond more quickly and be more susceptible to contamination from human activities at the land surface, than the deeper aquifers. The SWRCB’s GAMA Program was developed in response to the Groundwater Quality Monitoring Act of 2001 (Water Code sections 10780-10782.3): a public mandate to assess and monitor the quality of groundwater resources used for drinking-water supplies, and to increase the availability of information about groundwater quality to the public. The U.S. Geological Survey is the technical lead of the Priority Basin Project. Stewardship of California’s groundwater resources is a responsibility shared between well owners, communities, and the State. Participants and collaborators in the GAMA Program include Regional Water Quality Control Boards, Department of Water Resources, Department of Public Health, local and regional groundwater management entities, county and local water agencies, community groups, and private citizens. Well-owner participation in the GAMA Program is entirely voluntary.

  13. U.S. Geological Survey quality-assurance plan for continuous water-quality monitoring in Kansas, 2014

    USGS Publications Warehouse

    Bennett, Trudy J.; Graham, Jennifer L.; Foster, Guy M.; Stone, Mandy L.; Juracek, Kyle E.; Rasmussen, Teresa J.; Putnam, James E.

    2014-01-01

    A quality-assurance plan for use in conducting continuous water-quality monitoring activities has been developed for the Kansas Water Science Center in accordance with guidelines set forth by the U.S. Geological Survey. This quality-assurance plan documents the standards, policies, and procedures used by the U.S. Geological Survey in Kansas for activities related to the collection, processing, storage, analysis, and release of continuous water-quality monitoring data. The policies and procedures that are documented in this quality-assurance plan for continuous water-quality monitoring activities complement quality-assurance plans for surface-water and groundwater activities in Kansas.

  14. 40 CFR Appendix A to Part 58 - Quality Assurance Requirements for SLAMS, SPMs and PSD Air Monitoring

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... monitor. 3.3.4.4Pb Performance Evaluation Program (PEP) Procedures. Each year, one performance evaluation... Information 2. Quality System Requirements 3. Measurement Quality Check Requirements 4. Calculations for Data... 10 of this appendix) and at a national level in references 1, 2, and 3 of this appendix. 1...

  15. 40 CFR Appendix A to Part 58 - Quality Assurance Requirements for SLAMS, SPMs and PSD Air Monitoring

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... monitor. 3.3.4.4Pb Performance Evaluation Program (PEP) Procedures. Each year, one performance evaluation... Information 2. Quality System Requirements 3. Measurement Quality Check Requirements 4. Calculations for Data... 10 of this appendix) and at a national level in references 1, 2, and 3 of this appendix. 1...

  16. Power analysis and trend detection for water quality monitoring data. An application for the Greater Yellowstone Inventory and Monitoring Network

    USGS Publications Warehouse

    Irvine, Kathryn M.; Manlove, Kezia; Hollimon, Cynthia

    2012-01-01

    An important consideration for long term monitoring programs is determining the required sampling effort to detect trends in specific ecological indicators of interest. To enhance the Greater Yellowstone Inventory and Monitoring Network’s water resources protocol(s) (O’Ney 2006 and O’Ney et al. 2009 [under review]), we developed a set of tools to: (1) determine the statistical power for detecting trends of varying magnitude in a specified water quality parameter over different lengths of sampling (years) and different within-year collection frequencies (monthly or seasonal sampling) at particular locations using historical data, and (2) perform periodic trend analyses for water quality parameters while addressing seasonality and flow weighting. A power analysis for trend detection is a statistical procedure used to estimate the probability of rejecting the hypothesis of no trend when in fact there is a trend, within a specific modeling framework. In this report, we base our power estimates on using the seasonal Kendall test (Helsel and Hirsch 2002) for detecting trend in water quality parameters measured at fixed locations over multiple years. We also present procedures (R-scripts) for conducting a periodic trend analysis using the seasonal Kendall test with and without flow adjustment. This report provides the R-scripts developed for power and trend analysis, tutorials, and the associated tables and graphs. The purpose of this report is to provide practical information for monitoring network staff on how to use these statistical tools for water quality monitoring data sets.

  17. The ALICE data quality monitoring system

    NASA Astrophysics Data System (ADS)

    von Haller, B.; Telesca, A.; Chapeland, S.; Carena, F.; Carena, W.; Chibante Barroso, V.; Costa, F.; Denes, E.; Divià, R.; Fuchs, U.; Simonetti, G.; Soós, C.; Vande Vyvre, P.; ALICE Collaboration

    2011-12-01

    ALICE (A Large Ion Collider Experiment) is the heavy-ion detector designed to study the physics of strongly interacting matter and the quark-gluon plasma at the CERN Large Hadron Collider (LHC). The online Data Quality Monitoring (DQM) is a key element of the Data Acquisition's software chain. It provide shifters with precise and complete information to quickly identify and overcome problems, and as a consequence to ensure acquisition of high quality data. DQM typically involves the online gathering, the analysis by user-defined algorithms and the visualization of monitored data. This paper describes the final design of ALICE'S DQM framework called AMORE (Automatic MOnitoRing Environment), as well as its latest and coming features like the integration with the offline analysis and reconstruction framework, a better use of multi-core processors by a parallelization effort, and its interface with the eLogBook. The concurrent collection and analysis of data in an online environment requires the framework to be highly efficient, robust and scalable. We will describe what has been implemented to achieve these goals and the procedures we follow to ensure appropriate robustness and performance. We finally review the wide range of usages people make of this framework, from the basic monitoring of a single sub-detector to the most complex ones within the High Level Trigger farm or using the Prompt Reconstruction and we describe the various ways of accessing the monitoring results. We conclude with our experience, before and after the LHC startup, when monitoring the data quality in a challenging environment.

  18. Regional monitoring programs in the United States: Synthesis of four case studies from Pacific, Atlantic, and Gulf Coasts

    USGS Publications Warehouse

    Tango, Peter J.; Schiff, K.; Trowbridge, P.R.; Sherwood, E.T.; Batiuk, R.A.

    2016-01-01

    Water quality monitoring is a cornerstone of environmental protection and ambient monitoring provides managers with the critical data they need to take informed action. Unlike site-specific monitoring that is at the heart of regulatory permit compliance, regional monitoring can provide an integrated, holistic view of the environment, allowing managers to obtain a more complete picture of natural variability and cumulative impacts, and more effectively prioritize management actions. By reviewing four long-standing regional monitoring programs that cover portions of all three coasts in the United States – Chesapeake Bay, Tampa Bay, Southern California Bight, and San Francisco Bay – important insights can be gleaned about the benefits that regional monitoring provides to managers. These insights include the underlying reasons that make regional monitoring programs successful, the challenges to maintain relevance and viability in the face of ever-changing technology, competing demands and shifting management priorities. The lessons learned can help other managers achieve similar successes as they seek to establish and reinvigorate their own monitoring programs.

  19. Introduction - regional monitoring programs

    Treesearch

    Richard L. Hutto; C. John Ralph

    2005-01-01

    There is increasing interest in the initiation of regional or statewide monitoring programs that are less extensive than national efforts such as the Breeding Bird Survey. A number of regional programs have been in existence for a decade or more, so the papers in this section represented an effort to bring together the collective experience of the people who had...

  20. Tribal Air Quality Monitoring.

    ERIC Educational Resources Information Center

    Wall, Dennis

    2001-01-01

    The Institute for Tribal Environmental Professionals (ITEP) (Flagstaff, Arizona) provides training and support for tribal professionals in the technical job skills needed for air quality monitoring and other environmental management tasks. ITEP also arranges internships, job placements, and hands-on training opportunities and supports an…

  1. National Stream Quality Accounting Network and National Monitoring Network Basin Boundary Geospatial Dataset, 2008–13

    USGS Publications Warehouse

    Baker, Nancy T.

    2011-01-01

    This report and the accompanying geospatial data were created to assist in analysis and interpretation of water-quality data provided by the U.S. Geological Survey's National Stream Quality Accounting Network (NASQAN) and by the U.S. Coastal Waters and Tributaries National Monitoring Network (NMN), which is a cooperative monitoring program of Federal, regional, and State agencies. The report describes the methods used to develop the geospatial data, which was primarily derived from the National Watershed Boundary Dataset. The geospatial data contains polygon shapefiles of basin boundaries for 33 NASQAN and 5 NMN streamflow and water-quality monitoring stations. In addition, 30 polygon shapefiles of the closed and noncontributing basins contained within the NASQAN or NMN boundaries are included. Also included is a point shapefile of the NASQAN and NMN monitoring stations and associated basin and station attributes. Geospatial data for basin delineations, associated closed and noncontributing basins, and monitoring station locations are available at http://water.usgs.gov/GIS/metadata/usgswrd/XML/ds641_nasqan_wbd12.xml.

  2. Water Quality Monitoring: An Environmental Studies Unit for Biology 20/30. Teacher's Guide.

    ERIC Educational Resources Information Center

    Alberta Environment, Edmonton. Environmental Education Resources Branch.

    The objective of this environmental studies unit is to establish a water quality monitoring project for high school students in Alberta while simultaneously providing a unit which meets the objectives of the Biology 20 program (and which may also be used in Biology 10 and 30). Through this project, students assist in the collection,…

  3. Water Quality Monitoring: An Environmental Studies Unit for Biology 20/30. Student Manual.

    ERIC Educational Resources Information Center

    Alberta Environment, Edmonton. Environmental Education Resources Branch.

    The objective of this environmental studies unit is to establish a water quality monitoring project for high school students in Alberta while simultaneously providing a unit which meets the objectives of the Biology 20 program (and which may also be used in Biology 10 and 30). Through this project, students assist in the collection,…

  4. Water quality monitoring strategies - A review and future perspectives.

    PubMed

    Behmel, S; Damour, M; Ludwig, R; Rodriguez, M J

    2016-11-15

    The reliable assessment of water quality through water quality monitoring programs (WQMPs) is crucial in order for decision-makers to understand, interpret and use this information in support of their management activities aiming at protecting the resource. The challenge of water quality monitoring has been widely addressed in the literature since the 1940s. However, there is still no generally accepted, holistic and practical strategy to support all phases of WQMPs. The purpose of this paper is to report on the use cases a watershed manager has to address to plan or optimize a WQMP from the challenge of identifying monitoring objectives; selecting sampling sites and water quality parameters; identifying sampling frequencies; considering logistics and resources to the implementation of actions based on information acquired through the WQMP. An inventory and critique of the information, approaches and tools placed at the disposal of watershed managers was proposed to evaluate how the existing information could be integrated in a holistic, user-friendly and evolvable solution. Given the differences in regulatory requirements, water quality standards, geographical and geological differences, land-use variations, and other site specificities, a one-in-all solution is not possible. However, we advance that an intelligent decision support system (IDSS) based on expert knowledge that integrates existing approaches and past research can guide a watershed manager through the process according to his/her site-specific requirements. It is also necessary to tap into local knowledge and to identify the knowledge needs of all the stakeholders through participative approaches based on geographical information systems and adaptive survey-based questionnaires. We believe that future research should focus on developing such participative approaches and further investigate the benefits of IDSS's that can be updated quickly and make it possible for a watershed manager to obtain a

  5. Use of wetlands for water quality improvement under the USEPA Region V Clean Lakes Program

    NASA Astrophysics Data System (ADS)

    Landers, Judith C.; Knuth, Barbara A.

    1991-03-01

    The United States Environmental Protection Agency (USEPA) Region V Clean Lakes Program employs artificial and modified natural wetlands in an effort to improve the water quality of selected lakes. We examined use of wetlands at seven lake sites and evaluated the physical and institutional means by which wetland projects are implemented and managed, relative to USEPA program goals and expert recommendations on the use of wetlands for water quality improvement. Management practices recommended by wetlands experts addressed water level and retention, sheet flow, nutrient removal, chemical treatment, ecological and effectiveness monitoring, and resource enhancement. Institutional characteristics recommended included local monitoring, regulation, and enforcement and shared responsibilities among jurisdictions. Institutional and ecological objectives of the National Clean Lakes Program were met to some degree at every site. Social objectives were achieved to a lesser extent. Wetland protection mechanisms and appropriate institutional decentralization were present at all sites. Optimal management techniques were employed to varying degrees at each site, but most projects lack adequate monitoring to determine adverse ecological impacts and effectiveness of pollutant removal and do not extensively address needs for recreation and wildlife habitat. There is evidence that the wetland projects are contributing to improved lake water quality; however, more emphasis needs to be placed on wetland protection and long-term project evaluation.

  6. LHCb data quality monitoring

    NASA Astrophysics Data System (ADS)

    Adinolfi, M.; Archilli, F.; Baldini, W.; Baranov, A.; Derkach, D.; Panin, A.; Pearce, A.; Ustyuzhanin, A.

    2017-10-01

    Data quality monitoring, DQM, is crucial in a high-energy physics experiment to ensure the correct functioning of the experimental apparatus during the data taking. DQM at LHCb is carried out in two phases. The first one is performed on-site, in real time, using unprocessed data directly from the LHCb detector, while the second, also performed on-site, requires the reconstruction of the data selected by the LHCb trigger system and occurs later. For the LHC Run II data taking the LHCb collaboration has re-engineered the DQM protocols and the DQM graphical interface, moving the latter to a web-based monitoring system, called Monet, thus allowing researchers to perform the second phase off-site. In order to support the operator’s task, Monet is also equipped with an automated, fully configurable alarm system, thus allowing its use not only for DQM purposes, but also to track and assess the quality of LHCb software and simulation over time.

  7. 49 CFR 227.103 - Noise monitoring program.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Noise monitoring program. 227.103 Section 227.103..., DEPARTMENT OF TRANSPORTATION OCCUPATIONAL NOISE EXPOSURE Occupational Noise Exposure for Railroad Operating Employees. § 227.103 Noise monitoring program. (a) Schedule. A railroad shall develop and implement a noise...

  8. Ecological Monitoring and Compliance Program 2010 Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hansen, D.J.; Anderson, D.C.; Hall, D.B.

    The Ecological Monitoring and Compliance (EMAC) Program, funded through the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO), monitors the ecosystem of the Nevada National Security Site (NNSS) and ensures compliance with laws and regulations pertaining to NNSS biota. This report summarizes the program’s activities conducted by National Security Technologies, LLC (NSTec), during calendar year 2010. Program activities included (a) biological surveys at proposed construction sites, (b) desert tortoise compliance, (c) ecosystem monitoring, (d) sensitive plant species monitoring, (e) sensitive and protected/regulated animal monitoring, (f) habitat restoration monitoring, and (g) monitoring of the Nonproliferation Test andmore » Evaluation Complex (NPTEC). During 2010, all applicable laws, regulations, and permit requirements were met, enabling EMAC to achieve its intended goals and objectives.« less

  9. Ecological Monitoring and Compliance Program 2009 Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hansen, J. Dennis; Anderson, David C.; Hall, Derek B.

    The Ecological Monitoring and Compliance Program (EMAC), funded through the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office, monitors the ecosystem of the Nevada Test Site and ensures compliance with laws and regulations pertaining to NTS biota. This report summarizes the program’s activities conducted by National Security Technologies, LLC, during calendar year 2009. Program activities included (a) biological surveys at proposed construction sites, (b) desert tortoise compliance, (c) ecosystem mapping and data management, (d) sensitive plant species monitoring, (e) sensitive and protected/regulated animal monitoring, (f) habitat monitoring, (g) habitat restoration monitoring, and (h) monitoring of the Nonproliferationmore » Test and Evaluation Complex. During 2009, all applicable laws, regulations, and permit requirements were met, enabling EMAC to achieve its intended goals and objectives.« less

  10. 24 CFR 266.520 - Program monitoring and compliance.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... AUTHORITIES HOUSING FINANCE AGENCY RISK-SHARING PROGRAM FOR INSURED AFFORDABLE MULTIFAMILY PROJECT LOANS Project Management and Servicing § 266.520 Program monitoring and compliance. HUD will monitor the...

  11. 24 CFR 266.520 - Program monitoring and compliance.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... AUTHORITIES HOUSING FINANCE AGENCY RISK-SHARING PROGRAM FOR INSURED AFFORDABLE MULTIFAMILY PROJECT LOANS Project Management and Servicing § 266.520 Program monitoring and compliance. HUD will monitor the...

  12. 24 CFR 266.520 - Program monitoring and compliance.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... AUTHORITIES HOUSING FINANCE AGENCY RISK-SHARING PROGRAM FOR INSURED AFFORDABLE MULTIFAMILY PROJECT LOANS Project Management and Servicing § 266.520 Program monitoring and compliance. HUD will monitor the...

  13. 24 CFR 266.520 - Program monitoring and compliance.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... AUTHORITIES HOUSING FINANCE AGENCY RISK-SHARING PROGRAM FOR INSURED AFFORDABLE MULTIFAMILY PROJECT LOANS Project Management and Servicing § 266.520 Program monitoring and compliance. HUD will monitor the...

  14. 24 CFR 266.520 - Program monitoring and compliance.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... AUTHORITIES HOUSING FINANCE AGENCY RISK-SHARING PROGRAM FOR INSURED AFFORDABLE MULTIFAMILY PROJECT LOANS Project Management and Servicing § 266.520 Program monitoring and compliance. HUD will monitor the...

  15. AN INTERDISCIPLINARY APPROACH TO ADDRESSING NEIGHBORHOOD SCALE AIR QUALITY CONCERNS: THE INTEGRATION OF GIS, URBAN MORPHOLOGY, PREDICTIVE METEOROLOGY, AND AIR QUALITY MONITORING TOOLS

    EPA Science Inventory

    The paper describes a project that combines the capabilities of urban geography, raster-based GIS, predictive meteorological and air pollutant diffusion modeling, to support a neighborhood-scale air quality monitoring pilot study under the U.S. EPA EMPACT Program. The study ha...

  16. Assessing I-Grid(TM) web-based monitoring for power quality and reliability benchmarking

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Divan, Deepak; Brumsickle, William; Eto, Joseph

    2003-04-30

    This paper presents preliminary findings from DOEs pilot program. The results show how a web-based monitoring system can form the basis for aggregation of data and correlation and benchmarking across broad geographical lines. A longer report describes additional findings from the pilot, including impacts of power quality and reliability on customers operations [Divan, Brumsickle, Eto 2003].

  17. Citizen Science Opportunities for Monitoring Air Quality Fact Sheet

    EPA Pesticide Factsheets

    The Citizen Science Opportunities for Monitoring Air Quality fact sheet provides information on what citizen science is and the tools and resources available for citizen scientists interested in monitoring air quality.

  18. Ecological Monitoring and Compliance Program 2015 Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hall, Derek B.; Ostler, W. Kent; Anderson, David C.

    The Ecological Monitoring and Compliance Program (EMAC), funded through the U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office (NNSA/NFO), monitors the ecosystem of the Nevada National Security Site (NNSS) and ensures compliance with laws and regulations pertaining to NNSS biota. This report summarizes the program’s activities conducted by National Security Technologies, LLC (NSTec), during calendar year 2015. Program activities included (a) biological surveys at proposed activity sites, (b) desert tortoise compliance, (c) ecosystem monitoring, (d) sensitive plant species monitoring, (e) sensitive and protected/regulated animal monitoring, and (f) habitat restoration monitoring. During 2015, all applicable laws, regulations, andmore » permit requirements were met, enabling EMAC to achieve its intended goals and objectives.« less

  19. Ecological Monitoring and Compliance Program 2013 Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hall, Derek B.; Anderson, David C.; Greger, Paul D.

    The Ecological Monitoring and Compliance Program (EMAC), funded through the U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office (NNSA/NFO, formerly Nevada Site Office), monitors the ecosystem of the Nevada National Security Site (NNSS) and ensures compliance with laws and regulations pertaining to NNSS biota. This report summarizes the program’s activities conducted by National Security Technologies, LLC (NSTec), during calendar year 2013. Program activities included (a) biological surveys at proposed activity sites, (b) desert tortoise compliance, (c) ecosystem monitoring, (d) sensitive plant species monitoring, (e) sensitive and protected/regulated animal monitoring, and (f) habitat restoration monitoring. During 2013, allmore » applicable laws, regulations, and permit requirements were met, enabling EMAC to achieve its intended goals and objectives.« less

  20. Ecological Monitoring and Compliance Program 2016 Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hall, Derek; Perry, Jeanette; Ostler, W. Kent

    The Ecological Monitoring and Compliance Program (EMAC), funded through the U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office (NNSA/NFO), monitors the ecosystem of the Nevada National Security Site (NNSS) and ensures compliance with laws and regulations pertaining to NNSS biota. This report summarizes the program’s activities conducted by National Security Technologies, LLC (NSTec), during calendar year 2016. Program activities included (a) biological surveys at proposed activity sites, (b) desert tortoise compliance, (c) ecosystem monitoring, (d) sensitive plant species monitoring, (e) sensitive and protected/regulated animal monitoring, and (f) habitat restoration monitoring. During 2016, all applicable laws, regulations, andmore » permit requirements were met, enabling EMAC to achieve its intended goals and objectives.« less

  1. Implementation of a clinical quality control program in a mammography screening service of Brazil.

    PubMed

    DE Souza Sabino, Silvia Maria Prioli; Silva, Thiago Buosi; Watanabe, Anapaula Hidemi Uema; Syrjänen, Kari; Carvalho, André Lopes; Mauad, Edmundo Carvalho

    2014-09-01

    To evaluate the effect of a clinical quality control program on the final quality of a mammography screening service. We conducted retrospective assessment of the clinical quality of 5,000 mammograms taken in a Mammography Screening Program between November 2010 and September 2011, following the implementation of a Clinical Quality Control Program based on the European Guidelines. Among the 105,000 evaluated quality items, there were 8,588 failures (8.2%) - 1.7 failures per examination. Altogether, 89% of the failures were associated with positioning. The recall rate due to a technical error reached a maximum of 0.5% in the early phase of the observation period and subsequently stabilized (0.09%). The ongoing education and monitoring combined with personalized training increased the critical thinking of the involved professionals, reducing the technical failures and unnecessary exposure of patients to radiation, with substantial improvement in the final quality of mammography. Copyright© 2014 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  2. Development and implementation of a comprehensive quality assurance program at a community endoscopy facility.

    PubMed

    Hilsden, Robert Jay; Rostom, Alaa; Dubé, Catherine; Pontifex, Darlene; McGregor, S Elizabeth; Bridges, Ronald J

    2011-10-01

    Quality assurance (QA) is a process that includes the systematic evaluation of a service, institution of improvements and ongoing evaluation to ensure that effective changes were made. QA is a fundamental component of any organized colorectal cancer screening program. However, it should play an equally important role in opportunistic screening. Establishing the processes and procedures for a comprehensive QA program can be a daunting proposition for an endoscopy unit. The present article describes the steps taken to establish a QA program at the Forzani & MacPhail Colon Cancer Screening Centre (Calgary, Alberta) - a colorectal cancer screening centre and nonhospital endoscopy unit that is dedicated to providing colorectal cancer screening-related colonoscopies. Lessons drawn from the authors' experience may help others develop their own initiatives. The Global Rating Scale, a quality assessment and improvement tool developed for the gastrointestinal endoscopy services of the United Kingdom's National Health Service, was used as the framework to develop the QA program. QA activities include monitoring the patient experience through surveys, creating endoscopist report cards on colonoscopy performance, tracking and evaluating adverse events and monitoring wait times.

  3. What is in my air? Feds facilitating citizen science in the EPA Next Generation Air Monitoring Program

    NASA Astrophysics Data System (ADS)

    French, R. A.; Preuss, P.

    2013-12-01

    Recent advances in the development of small-scale and inexpensive air pollutant sensors, coupled with the ubiquitous use of wireless and mobile technology, will transform the field of air quality monitoring. For the first time, the general public may purchase air monitors, which can measure their personal exposure to NOx, Ozone, black carbon, and VOCs for a few hundred dollars. Concerned citizens may now gather the data for themselves to answer questions such as, ';what am I breathing?' and ';is my air clean?' The research and policy community will have access to real-time air quality data collected at the local and regional scale, making targeted protection of environmental health possible. With these benefits come many questions from citizen scientists, policymakers, and researchers. These include, what is the quality of the data? How will the public interpret data from the air sensors and are there guidelines to interpret that data? How do you know if the air sensor is trustworthy? Recognizing that this revolution in air quality monitoring will proceed regardless of the involvement of the government, the Innovation Team at the EPA Office of Research and Development, in partnership with the Office of Enforcement and Compliance Assistance and the Office of Air and Radiation, seized the opportunity to ensure that users of next generation air sensors can realize the full potential benefits of these innovative technologies. These efforts include releasing an EPA Draft Roadmap for Next Generation Air Monitoring, testing air sensors under laboratory and field conditions, field demonstrations of new air sensor technology for the public, and building a community of air sensor developers, researchers, local, state and federal officials, and community members through workshops and a website. This presentation will review the status of those programs, highlighting the particular programs of interest to citizen scientists. The Next Generation Air Monitoring program may serve

  4. Multiple ART Programs Create a Dilemma for Providers to Monitor ARV Adherence in Uganda.

    PubMed

    Obua, Celestino; Gusdal, Annelie; Waako, Paul; Chalker, John C; Tomson, Goran; Wahlström, Rolf; Team, The Inrud-Iaa

    2011-01-01

    Increased availability and accessibility of antiretroviral therapy (ART) has improved the length and quality of life amongst people living with HIV/AIDS. This has changed the landscape for care from episodic to long-term care that requires more monitoring of adherence. This has led to increased demand on human resources, a major problem for most ART programs. This paper presents experiences and perspectives of providers in ART facilities, exploring the organizational factors affecting their capacity to monitor adherence to ARVs. From an earlier survey to test adherence indicators and rank facilities as good, medium or poor adherence performances, six facilities were randomly selected, two from each rank. Observations on facility set-up, provider-patient interactions and key informant interviews were carried out. The strengths, weaknesses, opportunities and threats identified by health workers as facilitators or barriers to their capacity to monitor adherence to ARVs were explored during group discussions. Findings show that the performance levels of the facilities were characterized by four different organizational ART programs operating in Uganda, with apparent lack of integration and coordination at the facilities. Of the six facilities studied, the two high adherence performing facilities were Non-Governmental Organization (NGO) programs, while facilities with dual organizational programs (Governmental/NGO) performed poorly. Working conditions, record keeping and the duality of programs underscored the providers' capacity to monitor adherence. Overall 70% of the observed provider-patient interactions were conducted in environments that ensured privacy of the patient. The mean performance for record keeping was 79% and 50% in the high and low performing facilities respectively. Providers often found it difficult to monitor adherence due to the conflicting demands from the different organizational ART programs. Organizational duality at facilities is a major

  5. Model-based monitoring of stormwater runoff quality.

    PubMed

    Birch, Heidi; Vezzaro, Luca; Mikkelsen, Peter Steen

    2013-01-01

    Monitoring of micropollutants (MP) in stormwater is essential to evaluate the impacts of stormwater on the receiving aquatic environment. The aim of this study was to investigate how different strategies for monitoring of stormwater quality (combining a model with field sampling) affect the information obtained about MP discharged from the monitored system. A dynamic stormwater quality model was calibrated using MP data collected by automatic volume-proportional sampling and passive sampling in a storm drainage system on the outskirts of Copenhagen (Denmark) and a 10-year rain series was used to find annual average (AA) and maximum event mean concentrations. Use of this model reduced the uncertainty of predicted AA concentrations compared to a simple stochastic method based solely on data. The predicted AA concentration, obtained by using passive sampler measurements (1 month installation) for calibration of the model, resulted in the same predicted level but with narrower model prediction bounds than by using volume-proportional samples for calibration. This shows that passive sampling allows for a better exploitation of the resources allocated for stormwater quality monitoring.

  6. 40 CFR 75.21 - Quality assurance and quality control requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Quality assurance and quality control... PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Operation and Maintenance Requirements § 75.21 Quality assurance and quality control requirements. (a) Continuous emission monitoring systems. The owner or...

  7. Ecological Monitoring and Compliance Program 2012 Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hall, Derek B.; Anderson, David C.; Greger, Paul D.

    The Ecological Monitoring and Compliance Program (EMAC), funded through the U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office (NNSA/NFO, formerly Nevada Site Office), monitors the ecosystem of the Nevada National Security Site (NNSS) and ensures compliance with laws and regulations pertaining to NNSS biota. This report summarizes the program’s activities conducted by National Security Technologies, LLC (NSTec), during calendar year 2012. Program activities included (a) biological surveys at proposed construction sites, (b) desert tortoise compliance, (c) ecosystem monitoring, (d) sensitive plant species monitoring, (e) sensitive and protected/regulated animal monitoring, (f) habitat restoration monitoring, and (g) monitoring ofmore » the Nonproliferation Test and Evaluation Complex (NPTEC). During 2012, all applicable laws, regulations, and permit requirements were met, enabling EMAC to achieve its intended goals and objectives.« less

  8. National Forest Health Monitoring Program, Monitoring Urban Forests in Indiana: Pilot Study 2002, Part 2: Statewide Estimates Using the UFORE Model

    Treesearch

    David Nowak; Anne Buckelew Cumming; Daniel Twardus; Robert Hoehn; Manfred Mielke

    2007-01-01

    Trees in cities can improve environmental quality and human health. Unfortunately, little is known about the urban forest resource and what and how it contributes to local, regional, and national societies and economies. To better understand the urban forest resource and its value, the Forest Service, U.S. Department of Agriculture, Forest Health Monitoring Program...

  9. Region 7 States Air Quality Monitoring Plans - Iowa

    EPA Pesticide Factsheets

    National Ambient Air Quality Standard (NAAQS) - Iowa, Kansas, Missouri, and Nebraska; Annual Monitoring Network Plans, Five-Year Monitoring Network Assessments, and approval documentation. Each year, states are required to submit an annual monitoring netwo

  10. Region 7 States Air Quality Monitoring Plans - Missouri

    EPA Pesticide Factsheets

    National Ambient Air Quality Standard (NAAQS) - Iowa, Kansas, Missouri, and Nebraska; Annual Monitoring Network Plans, Five-Year Monitoring Network Assessments, and approval documentation. Each year, states are required to submit an annual monitoring netwo

  11. Region 7 States Air Quality Monitoring Plans - Nebraska

    EPA Pesticide Factsheets

    National Ambient Air Quality Standard (NAAQS) - Iowa, Kansas, Missouri, and Nebraska; Annual Monitoring Network Plans, Five-Year Monitoring Network Assessments, and approval documentation. Each year, states are required to submit an annual monitoring netwo

  12. Region 7 States Air Quality Monitoring Plans - Kansas

    EPA Pesticide Factsheets

    National Ambient Air Quality Standard (NAAQS) - Iowa, Kansas, Missouri, and Nebraska; Annual Monitoring Network Plans, Five-Year Monitoring Network Assessments, and approval documentation. Each year, states are required to submit an annual monitoring netwo

  13. A Water Quality Monitoring Programme for Schools and Communities

    ERIC Educational Resources Information Center

    Spellerberg, Ian; Ward, Jonet; Smith, Fiona

    2004-01-01

    A water quality monitoring programme for schools is described. The purpose of the programme is to introduce school children to the concept of reporting on the "state of the environment" by raising the awareness of water quality issues and providing skills to monitor water quality. The programme is assessed and its relevance in the…

  14. Water quality monitoring protocol for wadeable streams and rivers in the Northern Great Plains Network

    USGS Publications Warehouse

    Wilson, Marcia H.; Rowe, Barbara L.; Gitzen, Robert A.; Wilson, Stephen K.; Paintner-Green, Kara J.

    2014-01-01

    As recommended by Oakley et al. (2003), this protocol provides a narrative and the rationale for selection of streams and rivers within the NGPN that will be measured for water quality, including dissolved oxygen, pH, specific conductivity, and temperature. Standard operating procedures (SOPs) that detail the steps to collect, manage, and disseminate the NGPN water quality data are in an accompanying document. The sampling design documented in this protocol may be updated as monitoring information is collected and interpreted, and as refinement of methodologies develop through time. In addition, evaluation of data and refinement of the program may necessitate potential changes of program objectives. Changes to the NGPN water quality protocols and SOPs will be carefully documented in a revision history log.

  15. Alberta Biodiversity Monitoring Program - monitoring effectiveness of sustainable forest management planning

    Treesearch

    J. John Stadt; Jim Schieck; Harry Stelfox

    2006-01-01

    The Alberta Biodiversity Monitoring Program is a rigorous science-based initiative that is being developed to monitor and report on biodiversity status and trends throughout the province of Alberta, Canada. Forest management plans in Alberta are required to monitor and report on the achievement of stated sustainable forest management objectives; however, the...

  16. TU-F-CAMPUS-I-05: Semi-Automated, Open Source MRI Quality Assurance and Quality Control Program for Multi-Unit Institution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yung, J; Stefan, W; Reeve, D

    2015-06-15

    Purpose: Phantom measurements allow for the performance of magnetic resonance (MR) systems to be evaluated. Association of Physicists in Medicine (AAPM) Report No. 100 Acceptance Testing and Quality Assurance Procedures for MR Imaging Facilities, American College of Radiology (ACR) MR Accreditation Program MR phantom testing, and ACR MRI quality control (QC) program documents help to outline specific tests for establishing system performance baselines as well as system stability over time. Analyzing and processing tests from multiple systems can be time-consuming for medical physicists. Besides determining whether tests are within predetermined limits or criteria, monitoring longitudinal trends can also help preventmore » costly downtime of systems during clinical operation. In this work, a semi-automated QC program was developed to analyze and record measurements in a database that allowed for easy access to historical data. Methods: Image analysis was performed on 27 different MR systems of 1.5T and 3.0T field strengths from GE and Siemens manufacturers. Recommended measurements involved the ACR MRI Accreditation Phantom, spherical homogenous phantoms, and a phantom with an uniform hole pattern. Measurements assessed geometric accuracy and linearity, position accuracy, image uniformity, signal, noise, ghosting, transmit gain, center frequency, and magnetic field drift. The program was designed with open source tools, employing Linux, Apache, MySQL database and Python programming language for the front and backend. Results: Processing time for each image is <2 seconds. Figures are produced to show regions of interests (ROIs) for analysis. Historical data can be reviewed to compare previous year data and to inspect for trends. Conclusion: A MRI quality assurance and QC program is necessary for maintaining high quality, ACR MRI Accredited MR programs. A reviewable database of phantom measurements assists medical physicists with processing and monitoring of large

  17. Quality Management Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1991-10-01

    According to {section} 35.32, Quality Management Program,'' of 10 CFR Part 35, Medical Use of Byproduct Material,'' applicants or licensees, as applicable, are required to establish a quality management (QM) program. This regulatory guide provides guidance to licensees and applicants for developing policies and procedures for the QM program. This guide does not restrict or limit the licensee from using other guidance that may be equally useful in developing a QM program, e.g., information available from the Joint Commission on Accreditation of Healthcare Organizations or the American College of Radiology. Any information collection activities mentioned in this regulatory guide aremore » contained as requirements in 10 CFR Part 35, which provides the regulatory basis for this guide. This information collection requirements in 10 CFR Part 35 have been cleared under OMB Clearance No. 3150-0010.« less

  18. The immunization data quality audit: verifying the quality and consistency of immunization monitoring systems.

    PubMed Central

    Ronveaux, O.; Rickert, D.; Hadler, S.; Groom, H.; Lloyd, J.; Bchir, A.; Birmingham, M.

    2005-01-01

    OBJECTIVE: To evaluate the consistency and quality of immunization monitoring systems in 27 countries during 2002-03 using standardized data quality audits (DQAs) that had been launched within the framework of the Global Alliance for Vaccines and Immunization. METHODS: The consistency of reporting systems was estimated by determining the proportion of third doses of diphtheria-tetanuspertussis (DTP-3) vaccine reported as being administered that could be verified by written documentation at health facilities and districts. The quality of monitoring systems was measured using quality indices for different components of the monitoring systems. These indices were applied to each level of the health service (health unit, district and national). FINDINGS: The proportion of verified DTP-3 doses was lower than 85% in 16 countries. Difficulties in verifying the doses administered often arose at the peripheral level of the health service, usually as the result of discrepancies in information between health units and their corresponding districts or because completed recording forms were not available from health units. All countries had weaknesses in their monitoring systems; these included the inconsistent use of monitoring charts; inadequate monitoring of vaccine stocks, injection supplies and adverse events; unsafe computer practices; and poor monitoring of completeness and timeliness of reporting. CONCLUSION: Inconsistencies in immunization data occur in many countries, hampering their ability to manage their immunization programmes. Countries should use these findings to strengthen monitoring systems so that data can reliably guide programme activities. The DQA is an innovative tool that provides a way to independently assess the quality of immunization monitoring systems at all levels of a health service and serves as a point of entry to make improvements. It provides a useful example for other global health initiatives. PMID:16175824

  19. Regional Environmental Monitoring and Assessment Program Data (REMAP)

    EPA Pesticide Factsheets

    The Regional Environmental Monitoring and Assessment Program (REMAP) was initiated to test the applicability of the Environmental Monitoring and Assessment Program (EMAP) approach to answer questions about ecological conditions at regional and local scales. Using EMAP's statistical design and indicator concepts, REMAP conducts projects at smaller geographic scales and in shorter time frames than the national EMAP program.

  20. 45 CFR 2543.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 2543.51 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subaward, function or activity supported by the award. Recipients shall monitor subawards to...

  1. 45 CFR 2543.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 2543.51 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subaward, function or activity supported by the award. Recipients shall monitor subawards to...

  2. 45 CFR 2543.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 2543.51 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subaward, function or activity supported by the award. Recipients shall monitor subawards to...

  3. 45 CFR 2543.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Property Standards § 2543.51 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subaward, function or activity supported by the award. Recipients shall monitor subawards to...

  4. REGIONAL ENVIRONMENTAL MONITORING AND ASSESSMENT PROGRAM

    EPA Science Inventory

    The U.S. EPA Environmental Monitoring and Assessment Program (EMAP) supports the development and utilization of ecological monitoring as a critical component of environmental management and protection. Its authorization is provided under the Clean Water Act, as amended, Public L...

  5. Duke University's Quality Appearance Program

    ERIC Educational Resources Information Center

    Jackson, Joe

    2008-01-01

    The Grounds Services Unit at Duke University has implemented a new program that involves a process of self evaluation, which embraces the concept of perpetual and continuous improvement. The Quality Appearance Program (QAP) embellishes and expands upon the Quality Assurance Program concept, but with a twist to grounds management improvement…

  6. 23 CFR 637.207 - Quality assurance program.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 23 Highways 1 2010-04-01 2010-04-01 false Quality assurance program. 637.207 Section 637.207... CONSTRUCTION INSPECTION AND APPROVAL Quality Assurance Procedures for Construction § 637.207 Quality assurance program. (a) Each STD's quality assurance program shall provide for an acceptance program and an...

  7. Air pollution due to traffic, air quality monitoring along three sections of National Highway N-5, Pakistan.

    PubMed

    Ali, Mahboob; Athar, Makshoof

    2008-01-01

    Transportation system has contributed significantly to the development of human civilization; on the other hand it has an enormous impact on the ambient air quality in several ways. In this paper the air and noise pollution at selected sites along three sections of National Highway was monitored. Pakistan National Highway Authority has started a Highway Improvement program for rehabilitations and maintenance of National highways to improve the traffic flows, and would ultimately improve the air quality along highways. The ambient air quality and noise level was monitored at nine different locations along these sections of highways to quantify the air pollution. The duration of monitoring at individual location was 72 h. The most of the sampling points were near the urban or village population, schools or hospitals, in order to quantify the air pollution at most affected locations along these roads. A database consisting of information regarding the source of emission, local metrology and air quality may be created to assess the profile of air quality in the area.

  8. Effect of quality metric monitoring and colonoscopy performance.

    PubMed

    Razzak, Anthony; Smith, Dineen; Zahid, Maliha; Papachristou, Georgios; Khalid, Asif

    2016-10-01

    Background and aims: Adenoma detection rate (ADR) and cecal withdrawal time (CWT) have been identified as measures of colonoscopy quality. This study evaluates the impact of monitoring these measures on provider performance. Methods: Six blinded gastroenterologists practicing at a Veterans Affairs Medical Center were prospectively monitored over 9 months. Data for screening, adenoma surveillance, and fecal occult blood test positive (FOBT +) indicated colonoscopies were obtained, including exam preparation quality, cecal intubation rate, CWT, ADR, adenomas per colonoscopy (APC), and adverse events. Metrics were continuously monitored after a period of informed CWT monitoring and informed CWT + ADR monitoring. The primary outcome was impact on ADR and APC. Results: A total of 1671 colonoscopies were performed during the study period with 540 before informed monitoring, 528 during informed CWT monitoring, and 603 during informed CWT + ADR monitoring. No statistically significant impact on ADR was noted across each study phase. Multivariate regression revealed a trend towards fewer adenomas removed during the CWT monitoring phase (OR = 0.79; 95 %CI 0.62 - 1.02, P  = 0.065) and a trend towards more adenomas removed during the CWT + ADR monitoring phase when compared to baseline (OR = 1.26; 95 %CI 0.99 - 1.61, P  = 0.062). Indication for examination and provider were significant predictors for higher APC. Provider-specific data demonstrated a direct relationship between high ADR performers and increased CWT. Conclusions: Monitoring quality metrics did not significantly alter colonoscopy performance across a small heterogeneous group of providers. Non-significant trends towards higher APC were noted with CWT + ADR monitoring. Providers with a longer CWT had a higher ADR. Further studies are needed to determine the impact of monitoring on colonoscopy performance.

  9. Long Term Resource Monitoring Program procedures: fish monitoring

    USGS Publications Warehouse

    Ratcliff, Eric N.; Glittinger, Eric J.; O'Hara, T. Matt; Ickes, Brian S.

    2014-01-01

    This manual constitutes the second revision of the U.S. Army Corps of Engineers’ Upper Mississippi River Restoration-Environmental Management Program (UMRR-EMP) Long Term Resource Monitoring Program (LTRMP) element Fish Procedures Manual. The original (1988) manual merged and expanded on ideas and recommendations related to Upper Mississippi River fish sampling presented in several early documents. The first revision to the manual was made in 1995 reflecting important protocol changes, such as the adoption of a stratified random sampling design. The 1995 procedures manual has been an important document through the years and has been cited in many reports and scientific manuscripts. The resulting data collected by the LTRMP fish component represent the largest dataset on fish within the Upper Mississippi River System (UMRS) with more than 44,000 collections of approximately 5.7 million fish. The goal of this revision of the procedures manual is to document changes in LTRMP fish sampling procedures since 1995. Refinements to sampling methods become necessary as monitoring programs mature. Possible refinements are identified through field experiences (e.g., sampling techniques and safety protocols), data analysis (e.g., planned and studied gear efficiencies and reallocations of effort), and technological advances (e.g., electronic data entry). Other changes may be required because of financial necessity (i.e., unplanned effort reductions). This version of the LTRMP fish monitoring manual describes the most current (2014) procedures of the LTRMP fish component.

  10. 28 CFR 70.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., HOSPITALS AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Reports and Records § 70.51 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subaward, function or activity supported by the award. Recipients must monitor subawards...

  11. 15 CFR 14.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...-PROFIT, AND COMMERCIAL ORGANIZATIONS Post-Award Requirements Reports and Records § 14.51 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subaward, function or activity supported by the award. Recipients shall monitor subawards to...

  12. 14 CFR 1260.151 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Records § 1260.151 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subcontract, function or activity supported by the award. Recipients shall monitor subcontracts to ensure subcontractors have met the audit requirements as delineated...

  13. 29 CFR 95.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...-Award Requirements Reports and Records § 95.51 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subaward, function or activity supported by the award. Recipients shall monitor subawards to ensure subrecipients have met the audit...

  14. 29 CFR 95.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...-Award Requirements Reports and Records § 95.51 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subaward, function or activity supported by the award. Recipients shall monitor subawards to ensure subrecipients have met the audit...

  15. 29 CFR 95.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...-Award Requirements Reports and Records § 95.51 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subaward, function or activity supported by the award. Recipients shall monitor subawards to ensure subrecipients have met the audit...

  16. 14 CFR 1260.151 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Records § 1260.151 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subcontract, function or activity supported by the award. Recipients shall monitor subcontracts to ensure subcontractors have met the audit requirements as delineated...

  17. 15 CFR 14.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...-PROFIT, AND COMMERCIAL ORGANIZATIONS Post-Award Requirements Reports and Records § 14.51 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subaward, function or activity supported by the award. Recipients shall monitor subawards to...

  18. 29 CFR 95.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...-Award Requirements Reports and Records § 95.51 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subaward, function or activity supported by the award. Recipients shall monitor subawards to ensure subrecipients have met the audit...

  19. 14 CFR 1260.151 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Records § 1260.151 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subcontract, function or activity supported by the award. Recipients shall monitor subcontracts to ensure subcontractors have met the audit requirements as delineated...

  20. 28 CFR 70.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., HOSPITALS AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Reports and Records § 70.51 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subaward, function or activity supported by the award. Recipients must monitor subawards...

  1. 28 CFR 70.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., HOSPITALS AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Reports and Records § 70.51 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subaward, function or activity supported by the award. Recipients must monitor subawards...

  2. 28 CFR 70.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., HOSPITALS AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Reports and Records § 70.51 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subaward, function or activity supported by the award. Recipients must monitor subawards...

  3. 15 CFR 14.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...-PROFIT, AND COMMERCIAL ORGANIZATIONS Post-Award Requirements Reports and Records § 14.51 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subaward, function or activity supported by the award. Recipients shall monitor subawards to...

  4. 15 CFR 14.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...-PROFIT, AND COMMERCIAL ORGANIZATIONS Post-Award Requirements Reports and Records § 14.51 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subaward, function or activity supported by the award. Recipients shall monitor subawards to...

  5. An Architecture for Continuous Data Quality Monitoring in Medical Centers.

    PubMed

    Endler, Gregor; Schwab, Peter K; Wahl, Andreas M; Tenschert, Johannes; Lenz, Richard

    2015-01-01

    In the medical domain, data quality is very important. Since requirements and data change frequently, continuous and sustainable monitoring and improvement of data quality is necessary. Working together with managers of medical centers, we developed an architecture for a data quality monitoring system. The architecture enables domain experts to adapt the system during runtime to match their specifications using a built-in rule system. It also allows arbitrarily complex analyses to be integrated into the monitoring cycle. We evaluate our architecture by matching its components to the well-known data quality methodology TDQM.

  6. 22 CFR 226.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... ASSISTANCE AWARDS TO U.S. NON-GOVERNMENTAL ORGANIZATIONS Post-award Requirements Reports and Records § 226.51 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subaward, function or activity supported by the award. Recipients shall monitor...

  7. 22 CFR 226.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... ASSISTANCE AWARDS TO U.S. NON-GOVERNMENTAL ORGANIZATIONS Post-award Requirements Reports and Records § 226.51 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subaward, function or activity supported by the award. Recipients shall monitor...

  8. 22 CFR 226.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... ASSISTANCE AWARDS TO U.S. NON-GOVERNMENTAL ORGANIZATIONS Post-award Requirements Reports and Records § 226.51 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subaward, function or activity supported by the award. Recipients shall monitor...

  9. 22 CFR 226.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... ASSISTANCE AWARDS TO U.S. NON-GOVERNMENTAL ORGANIZATIONS Post-award Requirements Reports and Records § 226.51 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subaward, function or activity supported by the award. Recipients shall monitor...

  10. 40 CFR 52.995 - Enhanced ambient air quality monitoring.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Enhanced ambient air quality monitoring. 52.995 Section 52.995 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... air quality monitoring. (a) The Governor of the State of Louisiana submitted the photochemical...

  11. 40 CFR 52.995 - Enhanced ambient air quality monitoring.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Enhanced ambient air quality monitoring. 52.995 Section 52.995 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... air quality monitoring. (a) The Governor of the State of Louisiana submitted the photochemical...

  12. 40 CFR 52.995 - Enhanced ambient air quality monitoring.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Enhanced ambient air quality monitoring. 52.995 Section 52.995 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... air quality monitoring. (a) The Governor of the State of Louisiana submitted the photochemical...

  13. 40 CFR 52.995 - Enhanced ambient air quality monitoring.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Enhanced ambient air quality monitoring. 52.995 Section 52.995 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... air quality monitoring. (a) The Governor of the State of Louisiana submitted the photochemical...

  14. 40 CFR 52.995 - Enhanced ambient air quality monitoring.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Enhanced ambient air quality monitoring. 52.995 Section 52.995 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... air quality monitoring. (a) The Governor of the State of Louisiana submitted the photochemical...

  15. Monitoring Indoor Air Quality for Enhanced Occupational Health.

    PubMed

    Pitarma, Rui; Marques, Gonçalo; Ferreira, Bárbara Roque

    2017-02-01

    Indoor environments are characterized by several pollutant sources. Because people spend more than 90% of their time in indoor environments, several studies have pointed out the impact of indoor air quality on the etiopathogenesis of a wide number of non-specific symptoms which characterizes the "Sick Building Syndrome", involving the skin, the upper and lower respiratory tract, the eyes and the nervous system, as well as many building related diseases. Thus, indoor air quality (IAQ) is recognized as an important factor to be controlled for the occupants' health and comfort. The majority of the monitoring systems presently available is very expensive and only allow to collect random samples. This work describes the system (iAQ), a low-cost indoor air quality monitoring wireless sensor network system, developed using Arduino, XBee modules and micro sensors, for storage and availability of monitoring data on a web portal in real time. Five micro sensors of environmental parameters (air temperature, humidity, carbon monoxide, carbon dioxide and luminosity) were used. Other sensors can be added for monitoring specific pollutants. The results reveal that the system can provide an effective indoor air quality assessment to prevent exposure risk. In fact, the indoor air quality may be extremely different compared to what is expected for a quality living environment. Systems like this would have benefit as public health interventions to reduce the burden of symptoms and diseases related to "sick buildings".

  16. 34 CFR 303.501 - Supervision and monitoring of programs.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... supervision of programs and activities receiving assistance under this part; and (2) The monitoring of... 34 Education 2 2011-07-01 2010-07-01 true Supervision and monitoring of programs. 303.501 Section... INFANTS AND TODDLERS WITH DISABILITIES State Administration General § 303.501 Supervision and monitoring...

  17. 34 CFR 303.501 - Supervision and monitoring of programs.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... supervision of programs and activities receiving assistance under this part; and (2) The monitoring of... 34 Education 2 2010-07-01 2010-07-01 false Supervision and monitoring of programs. 303.501 Section... INFANTS AND TODDLERS WITH DISABILITIES State Administration General § 303.501 Supervision and monitoring...

  18. Establishing a national biological laboratory safety and security monitoring program.

    PubMed

    Blaine, James W

    2012-12-01

    The growing concern over the potential use of biological agents as weapons and the continuing work of the Biological Weapons Convention has promoted an interest in establishing national biological laboratory biosafety and biosecurity monitoring programs. The challenges and issues that should be considered by governments, or organizations, embarking on the creation of a biological laboratory biosafety and biosecurity monitoring program are discussed in this article. The discussion focuses on the following questions: Is there critical infrastructure support available? What should be the program focus? Who should be monitored? Who should do the monitoring? How extensive should the monitoring be? What standards and requirements should be used? What are the consequences if a laboratory does not meet the requirements or is not willing to comply? Would the program achieve the results intended? What are the program costs? The success of a monitoring program can depend on how the government, or organization, responds to these questions.

  19. Aspect-Oriented Monitoring of C Programs

    NASA Technical Reports Server (NTRS)

    Havelund, Klaus; VanWyk, Eric

    2008-01-01

    The paper presents current work on extending ASPECTC with state machines, resulting in a framework for aspect-oriented monitoring of C programs. Such a framework can be used for testing purposes, or it can be part of a fault protection strategy. The long term goal is to explore the synergy between the fields of runtime verification, focused on program monitoring, and aspect-oriented programming, focused on more general program development issues. The work is inspired by the observation that most work in this direction has been done for JAVA, partly due to the lack of easily accessible extensible compiler frameworks for C. The work is performed using the SILVER extensible attribute grammar compiler framework, in which C has been defined as a host language. Our work consists of extending C with ASPECTC, and subsequently to extend ASPECTC with state machines.

  20. Design of Cycle 3 of the National Water-Quality Assessment Program, 2013-23: Part 2: Science plan for improved water-quality information and management

    USGS Publications Warehouse

    Rowe, Gary L.; Belitz, Kenneth; Demas, Charlie R.; Essaid, Hedeff I.; Gilliom, Robert J.; Hamilton, Pixie A.; Hoos, Anne B.; Lee, Casey J.; Munn, Mark D.; Wolock, David W.

    2013-01-01

    This report presents a science strategy for the third decade of the National Water-Quality Assessment (NAWQA) Program, which since 1991, has been responsible for providing nationally consistent information on the quality of the Nation's streams and groundwater; how water quality is changing over time; and the major natural and human factors that affect current water quality conditions and trends. The strategy is based on an extensive evaluation of the accomplishments of NAWQA over its first two decades, the current status of water-quality monitoring activities by USGS and its partners, and an updated analysis of stakeholder priorities. The plan is designed to address priority issues and national needs identified by NAWQA stakeholders and the National Research Council (2012) irrespective of budget constraints. This plan describes four major goals for the third decade (Cycle 3), the approaches for monitoring, modeling, and scientific studies, key partnerships required to achieve these goals, and products and outcomes that will result from planned assessment activities. The science plan for 2013–2023 is a comprehensive approach to meet stakeholder priorities for: (1) rebuilding NAWQA monitoring networks for streams, rivers, and groundwater, and (2) upgrading models used to extrapolate and forecast changes in water-quality and stream ecosystem condition in response to changing climate and land use. The Cycle 3 plan continues approaches that have been central to the Program’s long-term success, but adjusts monitoring intensities and study designs to address critical information needs and identified data gaps. Restoration of diminished monitoring networks and new directions in modeling and interpretative studies address growing and evolving public and stakeholder needs for water-quality information and improved management, particularly in the face of increasing challenges related to population growth, increasing demands for water, and changing land use and climate

  1. Progress report on the ground-water, surface-water, and quality-of-water monitoring program, Black Mesa area, northeastern Arizona, 1987

    USGS Publications Warehouse

    Hill, G.W.; Sottilare, J.P.

    1987-01-01

    The N aquifer is an important source of water in the 5,400 sq-mi Black Mesa area on the Navajo and Hopi Indian Reservations. The Black Mesa monitoring program is designed to monitor long-term effects on the groundwater resources of the mesa as a result of withdrawals from the aquifer by the strip-mining operation of Peabody Coal Company. Withdrawals from the N aquifer by the mine increased from 95 acre-ft in 1968 to more than 4,480 acre-ft in 1986. Water levels in the confined area of the aquifer declined as much as 90 ft from 1965 to 1987 in some municipal and observation wells within about a 15-mi radius of the mine well field. Part of the drawdown in municipal wells is due to local pumpage. Water levels have not declined in wells tapping the unconfined area of the aquifer. Chemical analyses indicate no significant changes in the quality of water from wells that tap the N aquifer or from springs that discharge from several stratigraphic units, including the N aquifer, since pumping began at the mine. (USGS)

  2. National Water-Quality Assessment Program--Southern High Plains, Texas and New Mexico

    USGS Publications Warehouse

    Woodward, Dennis G.; Diniz, Cecilia G.

    1994-01-01

    BACKGROUND In 1991, the U.S. Geological Survey (USGS) began a National Water-Quality Assessment (NAWQA) program. The long-term goals of the NAWQA program are to describe the status of, and trends in, the quality of a large, representative part of the Nation's surface- and ground-water resources and to identify the major natural and human factors that affect the quality of these resources. In addressing these goals, the program will produce a wealth of water-quality information that will be useful to policy makers and managers at the National, State, and local levels. The NAWQA program emphasis is on regional water-quality problems. The program will not diminish the need for smaller studies and monitoring designed and currently being conducted by Federal, State, and local agencies to meet their individual needs. The NAWQA program, however, will provide a large-scale framework for conducting many of these activities and an understanding about National and regional water-quality conditions that cannot be acquired from individual, small-scale programs and studies. Studies of 60 hydrologic systems that include parts of most major river basins and aquifer systems (study-unit investigations) are the building blocks of the National assessment. The 60 study units range in size from 1,000 mi 2 (square miles) to more than 60,000 mi 2 and represent 60 to 70 percent of the Nation's water use and population served by public water supplies. Twenty study-unit investigations were started in 1991, 20 additional are starting in 1994, and 20 more are planned to start in 1997. The Southern High Plains study unit was selected as one of 20 study units to begin assessment activities in 1994. This study will be run from the New Mexico District office of the USGS in Albuquerque, New Mexico.

  3. Monitoring and Evaluating the Transition of Large-Scale Programs in Global Health

    PubMed Central

    Bao, James; Rodriguez, Daniela C; Paina, Ligia; Ozawa, Sachiko; Bennett, Sara

    2015-01-01

    Purpose: Donors are increasingly interested in the transition and sustainability of global health programs as priorities shift and external funding declines. Systematic and high-quality monitoring and evaluation (M&E) of such processes is rare. We propose a framework and related guiding questions to systematize the M&E of global health program transitions. Methods: We conducted stakeholder interviews, searched the peer-reviewed and gray literature, gathered feedback from key informants, and reflected on author experiences to build a framework on M&E of transition and to develop guiding questions. Findings: The conceptual framework models transition as a process spanning pre-transition and transition itself and extending into sustained services and outcomes. Key transition domains include leadership, financing, programming, and service delivery, and relevant activities that drive the transition in these domains forward include sustaining a supportive policy environment, creating financial sustainability, developing local stakeholder capacity, communicating to all stakeholders, and aligning programs. Ideally transition monitoring would begin prior to transition processes being implemented and continue for some time after transition has been completed. As no set of indicators will be applicable across all types of health program transitions, we instead propose guiding questions and illustrative quantitative and qualitative indicators to be considered and adapted based on the transition domains identified as most important to the particular health program transition. The M&E of transition faces new and unique challenges, requiring measuring constructs to which evaluators may not be accustomed. Many domains hinge on measuring “intangibles” such as the management of relationships. Monitoring these constructs may require a compromise between rigorous data collection and the involvement of key stakeholders. Conclusion: Monitoring and evaluating transitions in global

  4. 42 CFR 422.152 - Quality improvement program.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., quality of life indicators, depression scales, or chronic disease outcomes). (iii) Staff implementation of... 42 Public Health 3 2011-10-01 2011-10-01 false Quality improvement program. 422.152 Section 422... (CONTINUED) MEDICARE PROGRAM MEDICARE ADVANTAGE PROGRAM Quality Improvement § 422.152 Quality improvement...

  5. 42 CFR 422.152 - Quality improvement program.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., psychosocial, or clinical domains (for example, quality of life indicators, depression scales, or chronic... 42 Public Health 3 2010-10-01 2010-10-01 false Quality improvement program. 422.152 Section 422... (CONTINUED) MEDICARE PROGRAM MEDICARE ADVANTAGE PROGRAM Quality Improvement § 422.152 Quality improvement...

  6. 42 CFR 422.152 - Quality improvement program.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., quality of life indicators, depression scales, or chronic disease outcomes). (iii) Staff implementation of... 42 Public Health 3 2014-10-01 2014-10-01 false Quality improvement program. 422.152 Section 422... (CONTINUED) MEDICARE PROGRAM (CONTINUED) MEDICARE ADVANTAGE PROGRAM Quality Improvement § 422.152 Quality...

  7. 42 CFR 422.152 - Quality improvement program.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., quality of life indicators, depression scales, or chronic disease outcomes). (iii) Staff implementation of... 42 Public Health 3 2012-10-01 2012-10-01 false Quality improvement program. 422.152 Section 422... (CONTINUED) MEDICARE PROGRAM (CONTINUED) MEDICARE ADVANTAGE PROGRAM Quality Improvement § 422.152 Quality...

  8. 42 CFR 422.152 - Quality improvement program.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., quality of life indicators, depression scales, or chronic disease outcomes). (iii) Staff implementation of... 42 Public Health 3 2013-10-01 2013-10-01 false Quality improvement program. 422.152 Section 422... (CONTINUED) MEDICARE PROGRAM (CONTINUED) MEDICARE ADVANTAGE PROGRAM Quality Improvement § 422.152 Quality...

  9. Characterization monitoring & sensor technology crosscutting program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-08-01

    The purpose of the Characterization, Monitoring, and Sensor Technology Crosscutting Program (CMST-CP) is to deliver appropriate characterization, monitoring, and sensor technology (CMST) to the OFfice of Waste Management (EM-30), the Office of Environmental Restoration (EM-40), and the Office of Facility Transition and Management (EM-60).

  10. NASA's Lunar Impact Monitoring Program

    NASA Technical Reports Server (NTRS)

    Suggs, Robert M.; Cooke, William; Swift, Wesley; Hollon, Nicholas

    2007-01-01

    NASA's Meteoroid Environment Office nas implemented a program to monitor the Moon for meteoroid impacts from the Marshall Space Flight Center. Using off-the-shelf telescopes and video equipment, the moon is monitored for as many as 10 nights per month, depending on weather. Custom software automatically detects flashes which are confirmed by a second telescope, photometrically calibrated using background stars, and published on a website for correlation with other observations, Hypervelocity impact tests at the Ames Vertical Gun Facility have been performed to determine the luminous efficiency ana ejecta characteristics. The purpose of this research is to define the impact ejecta environment for use by lunar spacecraft designers of the Constellation (manned lunar) Program. The observational techniques and preliminary results will be discussed.

  11. High quality data: An evaluation of AIM data quality and data quality procedures

    USDA-ARS?s Scientific Manuscript database

    The goal of every monitoring program is to collect high-quality data which can then be used to provide information to decision makers. The Bureau of Land Management (BLM) Assessment, Inventory, and Monitoring (AIM) program is one such data set which provides rangeland status, condition, and trend in...

  12. Specification and Error Pattern Based Program Monitoring

    NASA Technical Reports Server (NTRS)

    Havelund, Klaus; Johnson, Scott; Rosu, Grigore; Clancy, Daniel (Technical Monitor)

    2001-01-01

    We briefly present Java PathExplorer (JPAX), a tool developed at NASA Ames for monitoring the execution of Java programs. JPAX can be used not only during program testing to reveal subtle errors, but also can be applied during operation to survey safety critical systems. The tool facilitates automated instrumentation of a program in order to properly observe its execution. The instrumentation can be either at the bytecode level or at the source level when the source code is available. JPaX is an instance of a more general project, called PathExplorer (PAX), which is a basis for experiments rather than a fixed system, capable of monitoring various programming languages and experimenting with other logics and analysis techniques

  13. Soil quality monitoring: Examples of existing protocols

    Treesearch

    Daniel G. Neary; Carl C. Trettin; Deborah Page-Dumroese

    2010-01-01

    Many forestry and agricultural agencies and organizations worldwide have developed soil monitoring and quality standards and guidelines to ensure future sustainability of land management. These soil monitoring standards are typically developed in response to international initiatives such as the Montreal Process, the Helsinki Ministerial Conference,or in support of...

  14. Soil quality monitoring: examples of existing protocols

    Treesearch

    Daniel G. Neary; Carl C. Trettin; Deborah Page-Dumroese

    2010-01-01

    Many forestry and agricultural agencies and organizations worldwide have developed soil monitoring and quality standards and guidelines to ensure future sustainability of land management. These soil monitoring standards are typically developed in response to international initiatives such as the Montreal Process, the Helsinki Ministerial Conference, or in support of...

  15. Choosing optimum station configurations for summarizing water quality characteristics, in 1994 Annual Report, San Francisco Estuary Regional Monitoring Program for Trace Substances: San Francisco Estuary Institute

    USGS Publications Warehouse

    Cloern, James E.; Cole, Brian E.; Caffrey, J.M.

    1996-01-01

    In this report, we focus on selection of an “optimum” station configuration for the channel of San Francisco Bay for vertical profiling of water quality. Our analysis is based on the monthly cruises conducted by the USGS under the auspices of the Regional Monitoring Program for Trace Substances (Caffrey et al. 1994; SFEI 1994). The underlying rationale for undertaking the analysis is that the distribution of trace substances is structured, at least in part, by the same forces acting on water quality parameters. This must be true to some extent, as trace substance concentrations are partially dependent on water quality characteristics such as salinity. On the other hand, the quantitative importance of these parameters in accounting for overall variability in individual trace substances is unknown. Furthermore, trace substances have their own unique sources, and these sources may dominate their distribution.

  16. Quality Assurance and School Monitoring in Hong Kong

    ERIC Educational Resources Information Center

    Mok, Magdalena Mo Ching

    2007-01-01

    This study reports on the Hong Kong education quality assurance and school monitoring system. Three research questions were addressed: (1) Who controls the quality of school education in Hong Kong? (2) What strategies are used in the Hong Kong school education quality assurance process? (3) Agenda for Future Research on quality assurance and…

  17. Key Factors for a High-Quality Peritoneal Dialysis Program — The Role of the PD Team and Continuous Quality Improvement

    PubMed Central

    Fang, Wei; Ni, Zhaohui; Qian, Jiaqi

    2014-01-01

    The proportion of end-stage renal disease (ESRD) patients on peritoneal dialysis (PD) has increased very fast in China over the last decade. Renji Hospital, affiliated with Shanghai Jiaotong University School of Medicine, is a recognized high-quality PD unit with a high PD utilization rate, excellent patient and technique survival (1-year and 5-year patient survival rate of 93% and 71%, and 1-year and 5-year technique survival of 96% and 82%, respectively), low peritonitis rate and a well-documented good quality of life of the treated patients. We believe that a dedicated and experienced PD team, a structured patient training program, continuous patient support, establishing and utilizing standardized protocols, starting PD with low dialysis dose, monitoring key performance indicators (KPIs), and continuous quality improvement (CQI) are the key factors underlying this successful PD program. PMID:24962961

  18. Selection of monitoring locations for storm water quality assessment.

    PubMed

    Langeveld, J G; Boogaard, F; Liefting, H J; Schilperoort, R P S; Hof, A; Nijhof, H; de Ridder, A C; Kuiper, M W

    2014-01-01

    Storm water runoff is a major contributor to the pollution of receiving waters. Storm water characteristics may vary significantly between locations and events. Hence, for each given location, this necessitates a well-designed monitoring campaign prior to selection of an appropriate storm water management strategy. The challenge for the design of a monitoring campaign with a given budget is to balance detailed monitoring at a limited number of locations versus less detailed monitoring at a large number of locations. This paper proposes a methodology for the selection of monitoring locations for storm water quality monitoring, based on (pre-)screening, a quick scan monitoring campaign, and final selection of locations and design of the monitoring setup. The main advantage of the method is the ability to prevent the selection of monitoring locations that turn out to be inappropriate. In addition, in this study, the quick scan resulted in a first useful dataset on storm water quality and a strong indication of illicit connections at one of the monitoring locations.

  19. ENVIRONMENTAL MONITORING AND ASSESSMENT PROGRAM - AGROECOSYSTEM PILOT FIELD PROGRAM PLAN - 1993

    EPA Science Inventory

    The Agroecosystem Resource Group (ARG) of the Environmental Monitoring and Assessment Program (EMAP) has developed a five-year (1991-1995) strategy for the development, evaluation, and implementation of a suite of indicators for monitoring agroecosystem status and trends on a reg...

  20. Core components of a comprehensive quality assurance program in anatomic pathology.

    PubMed

    Nakhleh, Raouf E

    2009-11-01

    In this article the core components of a comprehensive quality assurance and improvement plan are outlined. Quality anatomic pathology work comes with focus on accurate, timely, and complete reports. A commitment to continuous quality improvement and a systems approach with a persistent effort helps to achieve this end. Departments should have a quality assurance and improvement plan that includes a risk assessment of real and potential problems facing the laboratory. The plan should also list the individuals responsible for carrying out the program with adequate resources, a defined timetable, and annual assessment for progress and future directions. Quality assurance monitors should address regulatory requirements and be organized by laboratory division (surgical pathology, cytology, etc) as well as 5 segments (preanalytic, analytic, postanalytic phases of the test cycle, turn-around-time, and customer satisfaction). Quality assurance data can also be used to evaluate individual pathologists using multiple parameters with peer group comparison.

  1. Evaluation of a monitoring program for assessing the effects of management practices on the quantity and quality of drainwater from the Panoche Water District, western San Joaquin Valley, California

    USGS Publications Warehouse

    Leighton, David A.; Fio, John L.

    1995-01-01

    An evaluation was made of an existing monitoring program in the Panoche Water District for 1986-93. The Panoche Water District is an agricultural area located in the western San Joaquin Valley of California. Because irrigation drainage from this area has high concentrations of dissolved solids and selenium, management strategies have been developed to improve the quality of drainwater discharge. The purpose of the Panoche Water District's monitoring program is to assess the effects of water- and land-use practices on local ground water and drain flow from the district. Drainflow from the district consists of the discharge from 50 separate on-farm underground tile-drainage systems. The Panoche Water District maintains information on water deliveries, planned and actual crop types, and planned and actual acreages planted each year. In addition, the water district monitors ground-water and drainage-system discharges using a variety of data-collection methods. A total of 62 observation well sites are used to monitor ground-water level and quality. A total of 42 sites were monitored for drainflow quantity, and drain flow quality samples were collected from the outlets of each of the 50 drainage systems. However, these data were collected inconsistently and (or) intermittently during the period studied. All data obtained from the water district were compiled and stored in a geographic information system database. Water delivered for irrigation by the Panoche Water District is a mix of imported water and local ground water pumped directly into delivery canals. Although delivered water is a mix, information on the proportion of water from the two sources is not reported. Also, individual growers pump directly to their crops unknown quantities of ground water, the total of which could be greater than 60 percent of total applications during years when water district deliveries are greatly reduced (for example, the years during and following a drought). To evaluate the

  2. A conceptual ground-water-quality monitoring network for San Fernando Valley, California

    USGS Publications Warehouse

    Setmire, J.G.

    1985-01-01

    A conceptual groundwater-quality monitoring network was developed for San Fernando Valley to provide the California State Water Resources Control Board with an integrated, basinwide control system to monitor the quality of groundwater. The geology, occurrence and movement of groundwater, land use, background water quality, and potential sources of pollution were described and then considered in designing the conceptual monitoring network. The network was designed to monitor major known and potential point and nonpoint sources of groundwater contamination over time. The network is composed of 291 sites where wells are needed to define the groundwater quality. The ideal network includes four specific-purpose networks to monitor (1) ambient water quality, (2) nonpoint sources of pollution, (3) point sources of pollution, and (4) line sources of pollution. (USGS)

  3. Monitoring Air Quality with Leaf Yeasts.

    ERIC Educational Resources Information Center

    Richardson, D. H. S.; And Others

    1985-01-01

    Proposes that leaf yeast serve as quick, inexpensive, and effective techniques for monitoring air quality. Outlines procedures and provides suggestions for data analysis. Includes results from sample school groups who employed this technique. (ML)

  4. Quality assurance of the UV irradiances of the UV-B Monitoring and Research Program: the Mauna Loa test case

    NASA Astrophysics Data System (ADS)

    Zempila, Melina Maria; Davis, John; Janson, George; Olson, Becky; Chen, Maosi; Durham, Bill; Simpson, Scott; Straube, Jonathan; Sun, Zhibin; Gao, Wei

    2017-09-01

    The USDA UV-B Monitoring and Research Program (UVMRP) is an ongoing effort aiming to establish a valuable, longstanding database of ground-based ultraviolet (UV) solar radiation measurements over the US. Furthermore, the program aims to achieve a better understanding of UV variations through time, and develop a UV climatology for the Northern American section. By providing high quality radiometric measurements of UV solar radiation, UVMRP is also focusing on advancing science for agricultural, forest, and range systems in order to mitigate climate impacts. Within these foci, the goal of the present study is to investigate, analyze, and validate the accuracy of the measurements of the UV multi-filter rotating shadowband radiometer (UV-MFRSR) and Yankee (YES) UVB-1 sensor at the high altitude, pristine site at Mauna Loa, Hawaii. The response-weighted irradiances at 7 UV channels of the UV-MFRSR along with the erythemal dose rates from the UVB-1 radiometer are discussed, and evaluated for the period 2006-2015. Uncertainties during the calibration procedures are also analyzed, while collocated groundbased measurements from a Brewer spectrophotometer along with model simulations are used as a baseline for the validation of the data. Besides this quantitative research, the limitations and merits of the existing UVMRP methods are considered and further improvements are introduced.

  5. Winter wheat quality monitoring and forecasting system based on remote sensing and environmental factors

    NASA Astrophysics Data System (ADS)

    Haiyang, Yu; Yanmei, Liu; Guijun, Yang; Xiaodong, Yang; Dong, Ren; Chenwei, Nie

    2014-03-01

    To achieve dynamic winter wheat quality monitoring and forecasting in larger scale regions, the objective of this study was to design and develop a winter wheat quality monitoring and forecasting system by using a remote sensing index and environmental factors. The winter wheat quality trend was forecasted before the harvest and quality was monitored after the harvest, respectively. The traditional quality-vegetation index from remote sensing monitoring and forecasting models were improved. Combining with latitude information, the vegetation index was used to estimate agronomy parameters which were related with winter wheat quality in the early stages for forecasting the quality trend. A combination of rainfall in May, temperature in May, illumination at later May, the soil available nitrogen content and other environmental factors established the quality monitoring model. Compared with a simple quality-vegetation index, the remote sensing monitoring and forecasting model used in this system get greatly improved accuracy. Winter wheat quality was monitored and forecasted based on the above models, and this system was completed based on WebGIS technology. Finally, in 2010 the operation process of winter wheat quality monitoring system was presented in Beijing, the monitoring and forecasting results was outputted as thematic maps.

  6. Water quality program elements for Space Station Freedom

    NASA Technical Reports Server (NTRS)

    Sauer, Richard L.; Ramanathan, Raghupathy; Straub, John E.; Schultz, John R.

    1991-01-01

    A strategy is outlined for the development of water-quality criteria and standards relevant to recycling and monitoring the in-flight water for the Space Station Freedom (SSF). The water-reclamation subsystem of the SSF's ECLSS is described, and the objectives of the water-quality are set forth with attention to contaminants. Quality parameters are listed for potable and hygiene-related water including physical and organic parameters, inorganic constituents, bactericides, and microbial content. Comparisons are made to the quality parameters established for the Shuttle's potable water and to the EPA's current standards. Specific research is required to develop in-flight monitoring techniques for unique SSF contaminants, ECLSS microbial control, and on- and off-line monitoring. After discussing some of the in-flight water-monitoring hardware it is concluded that water reclamation and recycling are necessary and feasible for the SSF.

  7. 14 CFR § 1260.151 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Records § 1260.151 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subcontract, function or activity supported by the award. Recipients shall monitor subcontracts to ensure subcontractors have met the audit requirements as delineated...

  8. Federal Environmental Monitoring: Will the Bubble Burst?

    ERIC Educational Resources Information Center

    Miller, Stan

    1978-01-01

    A quality assurance program for environmental monitoring is identified as necesary for the collection of reliable, interchangeable, and legally defensible data. The article defines quality assurance and describes the EPA quality assurance program. (MA)

  9. Quality assurance programs for pressure ulcers.

    PubMed

    Xakellis, G C

    1997-08-01

    Traditional medical quality assurance programs are beginning to incorporate the principles of continuous quality improvement pioneered by Juran and Deming. Strategies for incorporating these principles into a long-term care facility are described, and two examples of successful implementation of continuous quality improvement programs for pressure ulcers are presented.

  10. ENVIRONMENTAL MONITORING AND ASSESSMENT PROGRAM: AGROECOSYSTEM 1992 PILOT PLAN

    EPA Science Inventory

    The Agroecosystem Resource Group (ARG) of the Environmental Protection Monitoring and Assessment Program (EMAP) has developed a five year program strategy for implementation of a suite of indicators for monitoring agroecosystem status and trends. he five-year period (1991-1995) i...

  11. 40 CFR 30.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Reports and Records § 30.51 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subaward, function or activity supported by the award...

  12. 40 CFR 30.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Reports and Records § 30.51 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subaward, function or activity supported by the award...

  13. 40 CFR 30.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Reports and Records § 30.51 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subaward, function or activity supported by the award...

  14. 40 CFR 30.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Reports and Records § 30.51 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subaward, function or activity supported by the award...

  15. Blackbird Creek Monitoring Program to Study the impact of Climate Change and Land Use

    NASA Astrophysics Data System (ADS)

    Ozbay, G.; Chintapenta, L. K.; Roeske, K. P.; Stone, M.; Phalen, L.

    2014-12-01

    The Blackbird Creek Monitoring Program at Delaware State University continues to utilize various perspectives to study the dynamics of one of Delaware's most pristine ecosystems. The water quality of Blackbird Creek has been constantly monitored for 3 years and correlated with the rain and storm events. Soil nutrients composition has been studied by extracting the water associated with soil aggregates and analyzing the levels of different nutrients. Soil quality is also assessed for heavy metals to identify potential human impact that may affect the health of ecosystem. Within the Blackbird Creek there is a threat to native plant communities from invasive plant species as they alter the ecosystem dynamics. Saltmarsh cord grass (Spartina alterniflora) and common reed (Phragmites australius) are the common wetland plants. Aerial mapping of the creek has been conducted to determine the area covered by invasive plant species. The microbial community structure plays a key role in soil carbon and nitrogen cycles in the ecosystem. Molecular analysis has been performed to study the microbial diversity with respect to the type of marsh grasses. This program has also incorporated the use of diatoms as biological indicators to assess the health of ecosystem and correlate that data with physical and chemical water quality data. The abundance and diversity of macro fauna such as blue crabs, fish and other significant species has also been studied. Stable isotopic analysis of these macro fauna has also been performed to study the food web. The results from this program will be helpful in addressing environmental challenges and designing management strategies.

  16. 49 CFR 180.505 - Quality assurance program.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Quality assurance program. 180.505 Section 180.505... MAINTENANCE OF PACKAGINGS Qualification and Maintenance of Tank Cars § 180.505 Quality assurance program. The quality assurance program requirements of § 179.7 of this subchapter apply. ...

  17. Assessing Quality in Home Visiting Programs

    ERIC Educational Resources Information Center

    Korfmacher, Jon; Laszewski, Audrey; Sparr, Mariel; Hammel, Jennifer

    2013-01-01

    Defining quality and designing a quality assessment measure for home visitation programs is a complex and multifaceted undertaking. This article summarizes the process used to create the Home Visitation Program Quality Rating Tool (HVPQRT) and identifies next steps for its development. The HVPQRT measures both structural and dynamic features of…

  18. Automated size-specific CT dose monitoring program: assessing variability in CT dose.

    PubMed

    Christianson, Olav; Li, Xiang; Frush, Donald; Samei, Ehsan

    2012-11-01

    . Additionally, considerable differences were noted in ED(adj) distributions between scanners, with scanners employing iterative reconstruction exhibiting significantly lower ED(adj) (range: 9%-64%). Finally, a significant difference (up to 59%) in ED(adj) distributions was observed between institutions, indicating the potential for dose reduction. The authors developed a robust automated size-specific radiation dose monitoring program for CT. Using this program, significant differences in ED(adj) were observed between scanner models and across institutions. This new dose monitoring program offers a unique tool for improving quality assurance and standardization both within and across institutions.

  19. Environment quality monitoring using ARM processor

    NASA Astrophysics Data System (ADS)

    Vinaya, C. H.; Krishna Thanikanti, Vamsi; Ramasamy, Sudha

    2017-11-01

    This paper of air quality monitoring system describes a model of sensors network to continuously monitoring the environment with low cost developed model. At present time all over the world turned into a great revolution in industrial domain and on the other hand environment get polluting in a dangerous value. There are so many technologies present to reduce the polluting contents but still there is no completely reduction of that pollution. Even there are different methods to monitor the pollution content; these are much costly that not everyone can adapt those methods or devices. Now we are proposing a sensors connected network to monitor the environment continuously and displaying the pollutant gases percentage in air surroundings and can transmit the results to our mobiles by message. The advantage of this system is easy to design, establish at area to monitor, maintenance and most cost effective as well.

  20. 22 CFR 145.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Reports and Records § 145.51 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subaward, function or activity supported by the award...

  1. 22 CFR 145.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Reports and Records § 145.51 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subaward, function or activity supported by the award...

  2. 22 CFR 145.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Reports and Records § 145.51 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subaward, function or activity supported by the award...

  3. 22 CFR 145.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Reports and Records § 145.51 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subaward, function or activity supported by the award...

  4. 36 CFR 1210.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Reports and Records § 1210.51 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subaward, function or activity supported by the award...

  5. 36 CFR 1210.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Reports and Records § 1210.51 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subaward, function or activity supported by the award...

  6. 36 CFR 1210.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Reports and Records § 1210.51 Monitoring and reporting program performance. (a) Recipients are responsible for managing and monitoring each project, program, subaward, function or activity supported by the award...

  7. 20 CFR 437.40 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Monitoring and reporting program performance. 437.40 Section 437.40 Employees' Benefits SOCIAL SECURITY ADMINISTRATION UNIFORM ADMINISTRATIVE... Reports, Records, Retention, and Enforcement § 437.40 Monitoring and reporting program performance. (a...

  8. Monitoring Quality of Biotherapeutic Products Using Multivariate Data Analysis.

    PubMed

    Rathore, Anurag S; Pathak, Mili; Jain, Renu; Jadaun, Gaurav Pratap Singh

    2016-07-01

    Monitoring the quality of pharmaceutical products is a global challenge, heightened by the implications of letting subquality drugs come to the market on public safety. Regulatory agencies do their due diligence at the time of approval as per their prescribed regulations. However, product quality needs to be monitored post-approval as well to ensure patient safety throughout the product life cycle. This is particularly complicated for biotechnology-based therapeutics where seemingly minor changes in process and/or raw material attributes have been shown to have a significant effect on clinical safety and efficacy of the product. This article provides a perspective on the topic of monitoring the quality of biotech therapeutics. In the backdrop of challenges faced by the regulatory agencies, the potential use of multivariate data analysis as a tool for effective monitoring has been proposed. Case studies using data from several insulin biosimilars have been used to illustrate the key concepts.

  9. Atmosphere and water quality monitoring on Space Station Freedom

    NASA Technical Reports Server (NTRS)

    Niu, William

    1990-01-01

    In Space Station Freedom air and water will be supplied in closed loop systems. The monitoring of air and water qualities will ensure the crew health for the long mission duration. The Atmosphere Composition Monitor consists of the following major instruments: (1) a single focusing mass spectrometer to monitor major air constituents and control the oxygen/nitrogen addition for the Space Station; (2) a gas chromatograph/mass spectrometer to detect trace contaminants; (3) a non-dispersive infrared spectrometer to determine carbon monoxide concentration; and (4) a laser particle counter for measuring particulates in the air. An overview of the design and development concepts for the air and water quality monitors is presented.

  10. TH-C-18A-06: Combined CT Image Quality and Radiation Dose Monitoring Program Based On Patient Data to Assess Consistency of Clinical Imaging Across Scanner Models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christianson, O; Winslow, J; Samei, E

    2014-06-15

    Purpose: One of the principal challenges of clinical imaging is to achieve an ideal balance between image quality and radiation dose across multiple CT models. The number of scanners and protocols at large medical centers necessitates an automated quality assurance program to facilitate this objective. Therefore, the goal of this work was to implement an automated CT image quality and radiation dose monitoring program based on actual patient data and to use this program to assess consistency of protocols across CT scanner models. Methods: Patient CT scans are routed to a HIPPA compliant quality assurance server. CTDI, extracted using opticalmore » character recognition, and patient size, measured from the localizers, are used to calculate SSDE. A previously validated noise measurement algorithm determines the noise in uniform areas of the image across the scanned anatomy to generate a global noise level (GNL). Using this program, 2358 abdominopelvic scans acquired on three commercial CT scanners were analyzed. Median SSDE and GNL were compared across scanner models and trends in SSDE and GNL with patient size were used to determine the impact of differing automatic exposure control (AEC) algorithms. Results: There was a significant difference in both SSDE and GNL across scanner models (9–33% and 15–35% for SSDE and GNL, respectively). Adjusting all protocols to achieve the same image noise would reduce patient dose by 27–45% depending on scanner model. Additionally, differences in AEC methodologies across vendors resulted in disparate relationships of SSDE and GNL with patient size. Conclusion: The difference in noise across scanner models indicates that protocols are not optimally matched to achieve consistent image quality. Our results indicated substantial possibility for dose reduction while achieving more consistent image appearance. Finally, the difference in AEC methodologies suggests the need for size-specific CT protocols to minimize variability in

  11. 10 CFR 63.144 - Quality assurance program change.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... assurance program information that duplicates language in quality assurance regulatory guides and quality... 10 Energy 2 2013-01-01 2013-01-01 false Quality assurance program change. 63.144 Section 63.144... REPOSITORY AT YUCCA MOUNTAIN, NEVADA Quality Assurance § 63.144 Quality assurance program change. Changes to...

  12. 10 CFR 63.144 - Quality assurance program change.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... assurance program information that duplicates language in quality assurance regulatory guides and quality... 10 Energy 2 2014-01-01 2014-01-01 false Quality assurance program change. 63.144 Section 63.144... REPOSITORY AT YUCCA MOUNTAIN, NEVADA Quality Assurance § 63.144 Quality assurance program change. Changes to...

  13. 10 CFR 63.144 - Quality assurance program change.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... assurance program information that duplicates language in quality assurance regulatory guides and quality... 10 Energy 2 2012-01-01 2012-01-01 false Quality assurance program change. 63.144 Section 63.144... REPOSITORY AT YUCCA MOUNTAIN, NEVADA Quality Assurance § 63.144 Quality assurance program change. Changes to...

  14. Lessons from monitoring water quality in San Francisco Bay

    USGS Publications Warehouse

    Cloern, J.E.; Schraga, T.S.; Lopez, C.B.; Labiosa, R.

    2003-01-01

    Bay Area residents feel a sense of responsibility to protect San Francisco Bay and keep it healthy. Some even dream about the recovery of fish stocks so they can sustain commercial fishing once again inside the Bay. How is our Bay doing? Is it highly polluted or pretty clean? How does its health compare with other estuaries in the United States? Are things getting better or worse? Does costly wastewater treatment have benefits? What are the biggest threats to the Bay and how can we reduce or eliminate those threats? How will the Bay change in the future? These questions can only be answered with investments in study and monitoring, and they are the driving force behind the Regional Monitoring Program (RMP). We describe here some selected results from water quality surveillance conducted by the U.S. Geological Survey (USGS) as one component of the RMP. We present results as lessons about how the Bay works as a complex dynamic system, and we show how these lessons are relevant to the broad RMP objectives supporting Bay protection and management.

  15. [Quality assurance program for pain management after obstetrical perineal injury].

    PubMed

    Urion, L; Bayoumeu, F; Jandard, C; Fontaine, B; Bouaziz, H

    2004-11-01

    A quality insurance program has been set up in order to improve the relief of pain in patients with perineal injury after childbirth. The program has been developed according to the French standards of accreditation. After elaboration of a referential, a first study (103 patients) allowed to evaluate the ongoing practices and to appreciate the pain intensities. After analysis of the results, an action strategy has been elaborated, with a brand new therapeutic standard and a pain-monitoring program for nurses. Six months later, a second study (105 patients) measured the efficiency of the accomplished actions. The statistic analysis used chi2 and Kruskal-Wallis tests and a multivariate analyse (p <0.05). Several indicators led to conclude to the success of this program: analgesics prescribed systematically and earlier, best observance, larger utilisation of the NSAI, decrease of the analgesics requests, improvement of the satisfaction referred to the relief of pain. The multivariate analyse showed a risk twice as little as in the second study to have a 36th hour VAS score superior to four (p =0.03). The apply of this quality insurance program allowed to improve the analgesia after obstetric perineal injuries. A few adaptations are needed, and also more formations of the medical and paramedical staff. The durability of the accomplished actions shall be evaluated in the future.

  16. Y-12 Groundwater Protection Program Groundwater Monitoring Data Compendium, Revision 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    This document is a compendium of water quality and hydrologic characterization data obtained through December 2005 from the network of groundwater monitoring wells and surface water sampling stations (including springs and building sumps) at the U.S. Department of Energy (DOE) Y-12 National Security Complex (Y-12) in Oak Ridge, Tennessee that have been sampled since January 2003. The primary objectives of this document, hereafter referenced as the Y-12 Groundwater Protection Program (GWPP) Compendium, are to: (1) Serve as a single-source reference for monitoring data that meet the requirements of the Y-12 GWPP, as defined in the Y-12 GWPP Management Plan (BWXTmore » Y-12 L.L.C. [BWXT] 2004); (2) Maintain a detailed analysis and evaluation of the monitoring data for each applicable well, spring, and surface water sampling station, with a focus on results for the primary inorganic, organic, and radiological contaminants in groundwater and surface water at Y-12; and (3) Ensure retention of ''institutional knowledge'' obtained over the long-term (>20-year) history of groundwater and surface water monitoring at Y-12 and the related sources of groundwater and surface water contamination. To achieve these goals, the Y-12 GWPP Compendium brings together salient hydrologic, geologic, geochemical, water-quality, and environmental compliance information that is otherwise disseminated throughout numerous technical documents and reports prepared in support of completed and ongoing environmental contamination assessment, remediation, and monitoring activities performed at Y-12. The following subsections provide background information regarding the overall scope and format of the Y-12 GWPP Compendium and the planned approach for distribution and revision (i.e., administration) of this ''living'' document.« less

  17. A proposed ground-water quality monitoring network for Idaho

    USGS Publications Warehouse

    Whitehead, R.L.; Parliman, D.J.

    1979-01-01

    A ground water quality monitoring network is proposed for Idaho. The network comprises 565 sites, 8 of which will require construction of new wells. Frequencies of sampling at the different sites are assigned at quarterly, semiannual, annual, and 5 years. Selected characteristics of the water will be monitored by both laboratory- and field-analysis methods. The network is designed to: (1) Enable water managers to keep abreast of the general quality of the State 's ground water, and (2) serve as a warning system for undesirable changes in ground-water quality. Data were compiled for hydrogeologic conditions, ground-water quality, cultural elements, and pollution sources. A ' hydrologic unit priority index ' is used to rank 84 hydrologic units (river basins or segments of river basins) of the State for monitoring according to pollution potential. Emphasis for selection of monitoring sites is placed on the 15 highest ranked units. The potential for pollution is greatest in areas of privately owned agricultural land. Other areas of pollution potential are residential development, mining and related processes, and hazardous waste disposal. Data are given for laboratory and field analyses, number of site visits, manpower, subsistence, and mileage, from which costs for implementing the network can be estimated. Suggestions are made for data storage and retrieval and for reporting changes in water quality. (Kosco-USGS)

  18. Total suspended solids concentrations and yields for water-quality monitoring stations in Gwinnett County, Georgia, 1996-2009

    USGS Publications Warehouse

    Landers, Mark N.

    2013-01-01

    The U.S. Geological Survey, in cooperation with the Gwinnett County Department of Water Resources, established a water-quality monitoring program during late 1996 to collect comprehensive, consistent, high-quality data for use by watershed managers. As of 2009, continuous streamflow and water-quality data as well as discrete water-quality samples were being collected for 14 watershed monitoring stations in Gwinnett County. This report provides statistical summaries of total suspended solids (TSS) concentrations for 730 stormflow and 710 base-flow water-quality samples collected between 1996 and 2009 for 14 watershed monitoring stations in Gwinnett County. Annual yields of TSS were estimated for each of the 14 watersheds using methods described in previous studies. TSS yield was estimated using linear, ordinary least-squares regression of TSS and explanatory variables of discharge, turbidity, season, date, and flow condition. The error of prediction for estimated yields ranged from 1 to 42 percent for the stations in this report; however, the actual overall uncertainty of the estimated yields cannot be less than that of the observed yields (± 15 to 20 percent). These watershed yields provide a basis for evaluation of how watershed characteristics, climate, and watershed management practices affect suspended sediment yield.

  19. 25 CFR 276.9 - Monitoring and reporting program performances.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... frequency with which the performance reports will be submitted with the Request for Advance or Reimbursement... 25 Indians 1 2010-04-01 2010-04-01 false Monitoring and reporting program performances. 276.9... reporting program performances. (a) Grantees shall constantly monitor the performance under grant-supported...

  20. 34 CFR 303.171 - Supervision and monitoring of programs.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 34 Education 2 2010-07-01 2010-07-01 false Supervision and monitoring of programs. 303.171 Section 303.171 Education Regulations of the Offices of the Department of Education (Continued) OFFICE OF...-Application Requirements § 303.171 Supervision and monitoring of programs. Each application must include...

  1. 34 CFR 303.171 - Supervision and monitoring of programs.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 34 Education 2 2011-07-01 2010-07-01 true Supervision and monitoring of programs. 303.171 Section 303.171 Education Regulations of the Offices of the Department of Education (Continued) OFFICE OF...-Application Requirements § 303.171 Supervision and monitoring of programs. Each application must include...

  2. Evaluation of Water Quality Trends in Goodwater Creek Experimental Watershed, Missouri: Implications for Monitoring Strategies and Objective Setting

    USDA-ARS?s Scientific Manuscript database

    Continued public support for U.S. tax-payer funded programs aimed at reducing agricultural non-point source pollutants depends on clear demonstrations of water quality improvements. Effectiveness of structural BMPs, as well as watershed monitoring networks is an important information need to make f...

  3. Letter Report: Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Caliente, Lincoln County, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. Englebrecht; I. Kavouras; D. Campbell

    2008-08-01

    The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Beatty, Sarcobatus Flats, Rachel, Caliente, Pahranagat NWR, Crater Flat, and Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d).more » The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data, on completion of the site's sampling program.« less

  4. Maternal Quality Standards for Children's Television Programs.

    ERIC Educational Resources Information Center

    Nikken, Peter; And Others

    1996-01-01

    Investigates the standards mothers use to evaluate four types of children's television programs: (1) cartoons; (2) news programs for children; (3) educational children's programs; and (4) dramatic children's programs. Three quality standards considered most important were comprehensibility, aesthetic quality, and elicitation of involvement.…

  5. Water Quality Monitoring of an Urban Estuary and a Coastal Aquifer Using Field Kits and Meters: A Community-Based Environmental Research Project

    ERIC Educational Resources Information Center

    Jung, Hun Bok; Zamora, Felix; Duzgoren-Aydin, Nurdan S.

    2017-01-01

    Water quality is an important interdisciplinary environmental topic for project-based learning. An undergraduate summer research internship program at a public minority serving institution engaged environmental science majors in community-based research experiences. The research focused on the field monitoring of water quality for surface water…

  6. Location and site characteristics of the ambient ground-water-quality-monitoring network in West Virginia

    USGS Publications Warehouse

    Kozar, M.D.; Brown, D.P.

    1995-01-01

    Ground-water-quality-monitoring sites have been established in compliance with the 1991 West Virginia "Groundwater Protection Act." One of the provisions of the "Groundwater Protection Act" is to conduct ground-water sampling, data collection, analyses, and evaluation with sufficient frequency so as to ascertain the characteristics and quality of ground water and the sufficiency of the ground- water protection programs established pursuant to the act (Chapter 20 of the code of West Virginia, 1991, Article 5-M). Information for 26 monitoring sites (wells and springs) which comprise the Statewide ambient ground-water-quality-monitoring network is presented. Areas in which monitoring sites were needed were determined by the West Virginia Division of Environmental Protection, Office of Water Resources in consultation with the U.S. Geological Survey (USGS). Initial sites were chosen on the basis of recent hydrogeologic investigations conducted by the USGS and from data stored in the USGS Ground Water Site Inventory database. Land use, aquifer setting, and areal coverage of the State are three of the more important criteria used in site selection. A field reconnaissance was conducted to locate and evaluate the adequacy of selected wells and springs. Descriptive information consisting of site, geologic, well construction, and aquifer-test data has been compiled. The 26 sites will be sampled periodically for iron, manganese, most common ions (for example, calcium, magnesium, sodium, potassium, sulfate, chloride, bicarbonate), volatile and semivolatile organic compounds (for example, pesticides and industrial solvents), and fecal coliform and fecal streptococcus bacteria. Background information explaining ground-water systems and water quality within the State has been included.

  7. 75 FR 41963 - Wheat and Oilseed Programs; Durum Wheat Quality Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-20

    ... Programs; Durum Wheat Quality Program AGENCY: Farm Service Agency and Commodity Credit Corporation, USDA. ACTION: Final rule. SUMMARY: This rule implements specific requirements for the Durum Wheat Quality... of the Council on Environmental Quality (40 CFR parts 1500-1508), and FSA regulations for compliance...

  8. Precipitation-chemistry measurements from the California Acid Deposition Monitoring Program, 1985-1990

    USGS Publications Warehouse

    Blanchard, Charles L.; Tonnessen, Kathy A.

    1993-01-01

    The configuration of the California Acid Deposition Monitoring Program (CADMP) precipitation network is described and quality assurance results summarized. Comparison of CADMP and the National Acid Deposition Program/National Trends Network (NADP/NTN) data at four parallel sites indicated that mean depth-weighted differences were less than 3 μeq ℓ−1 for all ions, being statistically significant for ammonium, sulfate and hydrogen ion. These apparently small differences were 15–30% of the mean concentrations of ammonium, sulfate and hydrogen ion. Mean depth-weighted concentrations and mass deposition rates for the period 1985–1990 are summarized; the latter were highest either where concentrations or precipitation depths were relatively high.

  9. Revisiting the concept of growth monitoring and its possible role in community-based nutrition programs.

    PubMed

    Mangasaryan, Nuné; Arabi, Mandana; Schultink, Werner

    2011-03-01

    Community-based growth monitoring (GM) and growth monitoring and promotion (GMP) have been implemented worldwide. The literature provides controversial messages regarding their effectiveness. Numerous countries have GM as their main community-based activity and need guidance for future programming. The notion of GM is usually clear, but the follow-up actions include a range of activities and interventions, all under the heading of "promotion." We suggested definitions, objectives, and outcomes of the GM and GMP. By providing some clarity on these conceptual issues we attempted to provide a basis for consensus building and development of recommendations on when this activity should be promoted or discouraged. We reviewed basic concepts and global experience of GM and GMP using publications about GM and GMP, UNICEF country reports and other publications, field observations, and reports of recent expert consultations. Realistic added benefits are suggested as compared with general counseling that could also be delivered outside the GM session. We provide a narrow definition of "promotion" in GMP, in which actions are tailored to the results of monitoring, as well as suggest quality implementation criteria. GM, even if complemented by a promotional package, can have only a limited impact if it is not part of a comprehensive program. GMP cannot be viewed as a competitor to highly effective interventions, but may serve as a possible platform for their delivery. The decision to build community-based programs on a GMP platform should be based on consideration of benefits, feasibility of quality implementation, and capacity of human resources.

  10. 40 CFR 257.24 - Detection monitoring program.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Disposal Units Ground-Water Monitoring and Corrective Action § 257.24 Detection monitoring program. (a... unit; (ii) The mobility, stability, and persistence of waste constituents or their reaction products in... constituents, and reaction products in the ground water; and (iv) The concentration or values and coefficients...

  11. SAMIRA - SAtellite based Monitoring Initiative for Regional Air quality

    NASA Astrophysics Data System (ADS)

    Schneider, Philipp; Stebel, Kerstin; Ajtai, Nicolae; Diamandi, Andrei; Horalek, Jan; Nicolae, Doina; Stachlewska, Iwona; Zehner, Claus

    2016-04-01

    Here, we present a new ESA-funded project entitled Satellite based Monitoring Initiative for Regional Air quality (SAMIRA), which aims at improving regional and local air quality monitoring through synergetic use of data from present and upcoming satellites, traditionally used in situ air quality monitoring networks and output from chemical transport models. Through collaborative efforts in four countries, namely Romania, Poland, the Czech Republic and Norway, all with existing air quality problems, SAMIRA intends to support the involved institutions and associated users in their national monitoring and reporting mandates as well as to generate novel research in this area. Despite considerable improvements in the past decades, Europe is still far from achieving levels of air quality that do not pose unacceptable hazards to humans and the environment. Main concerns in Europe are exceedances of particulate matter (PM), ground-level ozone, benzo(a)pyrene (BaP) and nitrogen dioxide (NO2). While overall sulfur dioxide (SO2) emissions have decreased in recent years, regional concentrations can still be high in some areas. The objectives of SAMIRA are to improve algorithms for the retrieval of hourly aerosol optical depth (AOD) maps from SEVIRI, and to develop robust methods for deriving column- and near-surface PM maps for the study area by combining satellite AOD with information from regional models. The benefit to existing monitoring networks (in situ, models, satellite) by combining these datasets using data fusion methods will be tested for satellite-based NO2, SO2, and PM/AOD. Furthermore, SAMIRA will test and apply techniques for downscaling air quality-related EO products to a spatial resolution that is more in line with what is generally required for studying urban and regional scale air quality. This will be demonstrated for a set of study sites that include the capitals of the four countries and the highly polluted areas along the border of Poland and the

  12. Analytical chemistry in water quality monitoring during manned space missions

    NASA Astrophysics Data System (ADS)

    Artemyeva, Anastasia A.

    2016-09-01

    Water quality monitoring during human spaceflights is essential. However, most of the traditional methods require sample collection with a subsequent ground analysis because of the limitations in volume, power, safety and gravity. The space missions are becoming longer-lasting; hence methods suitable for in-flight monitoring are demanded. Since 2009, water quality has been monitored in-flight with colorimetric methods allowing for detection of iodine and ionic silver. Organic compounds in water have been monitored with a second generation total organic carbon analyzer, which provides information on the amount of carbon in water at both the U.S. and Russian segments of the International Space Station since 2008. The disadvantage of this approach is the lack of compound-specific information. The recently developed methods and tools may potentially allow one to obtain in-flight a more detailed information on water quality. Namely, the microanalyzers based on potentiometric measurements were designed for online detection of chloride, potassium, nitrate ions and ammonia. The recent application of the current highly developed air quality monitoring system for water analysis was a logical step because most of the target analytes are the same in air and water. An electro-thermal vaporizer was designed, manufactured and coupled with the air quality control system. This development allowed for liberating the analytes from the aqueous matrix and further compound-specific analysis in the gas phase.

  13. Potential of integrated continuous surveys and quality management to support monitoring, evaluation, and the scale-up of health interventions in developing countries.

    PubMed

    Rowe, Alexander K

    2009-06-01

    Well-funded initiatives are challenging developing countries to increase health intervention coverage and show impact. Despite substantial resources, however, major obstacles include weak health systems, a lack of reasonably accurate monitoring data, and inadequate use of data for managing programs. This report discusses how integrated continuous surveys and quality management (I-Q), which are well-recognized approaches in wealthy countries, could support intervention scale-up, monitoring and evaluation, quality control for commodities, capacity building, and implementation research in low-resource settings. Integrated continuous surveys are similar to existing national cross-sectional surveys of households and health facilities, except data are collected over several years by permanent teams, and most results are reported monthly at the national, province, and district levels. Quality management involves conceptualizing work as processes, involving all workers in quality improvement, monitoring quality, and teams that improve quality with "plan-do-study-act" cycles. Implementing and evaluating I-Q in a low-income country would provide critical information on the value of this approach.

  14. The National Water-Quality Assessment Program of the United States: Strategies for Monitoring Trends and Results from the First Two Decades of Study: 1991-2011

    NASA Astrophysics Data System (ADS)

    Lindsey, B.; McMahon, P.; Rupert, M.; Tesoriero, J.; Starn, J.; Anning, D.; Green, C.

    2012-04-01

    The U.S. Geological Survey National Water-Quality Assessment (NAWQA) Program was implemented in 1991 to provide long-term, consistent, and comparable information on the quality of surface and groundwater resources of the United States. Findings are used to support national, regional, state, and local information needs with respect to water quality. The three main goals of the program are to 1) assess the condition of the nation's streams, rivers, groundwater, and aquatic systems; 2) assess how conditions are changing over time; and 3) determine how natural features and human activities affect these conditions, and where those effects are most pronounced. As data collection progressed into the second decade, the emphasis of the interpretation of the data has shifted from primarily understanding status, to evaluation of trends. The program has conducted national and regional evaluations of change in the quality of water in streams, rivers, groundwater, and health of aquatic systems. Evaluating trends in environmental systems requires complex analytical and statistical methods, and a periodic re-evaluation of the monitoring methods used to collect these data. Examples given herein summarize the lessons learned from the evaluation of changes in water quality during the past two decades with an emphasis on the finding with respect to groundwater. The analysis of trends in groundwater is based on 56 well networks located in 22 principal aquifers of the United States. Analysis has focused on 3 approaches: 1) a statistical analysis of results of sampling over various time scales, 2) studies of factors affecting trends in groundwater quality, and 3) use of models to simulate groundwater trends and forecast future trends. Data collection for analysis of changes in groundwater-quality has focused on decadal resampling of wells. Understanding the trends in groundwater quality and the factors affecting those trends has been conducted using quarterly sampling, biennial sampling

  15. Definition of air quality measurements for monitoring space shuttle launches

    NASA Technical Reports Server (NTRS)

    Thorpe, R. D.

    1978-01-01

    A description of a recommended air quality monitoring network to characterize the impact on ambient air quality in the Kennedy Space Center (KSC) (area) of space shuttle launch operations is given. Analysis of ground cloud processes and prevalent meteorological conditions indicates that transient HCl depositions can be a cause for concern. The system designed to monitor HCl employs an extensive network of inexpensive detectors combined with a central analysis device. An acid rain network is also recommended. A quantitative measure of projected minimal long-term impact involves the limited monitoring of NOx and particulates. All recommended monitoring is confined ti KSC property.

  16. The International Interlaboratory Quality Control Program for Measurement of Antiretroviral Drugs in Plasma: a global proficiency testing program.

    PubMed

    Burger, David; Teulen, Marga; Eerland, Jaco; Harteveld, Anneke; Aarnoutse, Rob; Touw, Daan

    2011-04-01

    The International Interlaboratory Quality Control Program for Measurement of Antiretroviral Drugs in Plasma was initiated in 1999 by Radboud University Nijmegen Medical Center, The Netherlands, and continued later on in collaboration with the Dutch Association for Quality Assessment in Therapeutic Drug Monitoring and Clinical Toxicology (www.kkgt.nl). The aim of this analysis was to evaluate the first 10 years of the Program and to determine variables associated with reporting of less accurate results. Two rounds are organized annually in which blind samples are shipped to participants containing a low, medium, or high concentration of each antiretroviral drug. Any reported result that deviates more than 20% from the spiked concentration is defined as inaccurate. By the end of 2009, the number of laboratories participating in the Program had increased to 56; 44 (79%) are located in Europe. A total of 12,798 test results was available for analysis, of which 2104 (16.4%) were reported as inaccurate. Performance was best for samples containing nevirapine (mean of inadequate scores per round: 11.1%) and lopinavir (11.9%) and worst for indinavir (18.7%), atazanavir (18.9%), saquinavir (19.6%), and nelfinavir (21.3%). High and medium concentrations were less frequently reported as inaccurate than low concentrations: 13.5%, 13.0%, and 22.4%, respectively. Although the overall performance of the laboratories varied per year, a trend was visible for improvement over time with 19.9% of the results being inaccurate in 2002 (n = 20 laboratories) to 15.7% in 2009 (n = 56 laboratories). The Program provides a proficiency testing program in which laboratories are alerted to potential analytical errors while performing therapeutic drug monitoring in HIV-infected patients. Laboratories should put more effort in adequately analyzing concentrations of antiretroviral drugs with low minimum effective concentrations.

  17. 23 CFR 637.207 - Quality assurance program.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... independent assurance (IA) program consisting of the following: (1) Acceptance program. (i) Each STD's... quality control samples. (C) The quality control sampling and testing is evaluated by an IA program. (iii... appropriate. See 23 CFR 635.413(e) for specific requirements. (2) The IA program shall evaluate the qualified...

  18. Y-12 Groundwater Protection Program Monitoring Optimization Plan for Groundwater Monitoring Wells at the U.S. Department of Energy Y-12 National Security Complex, Oak Ridge, Tennessee

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None, None

    This document is the monitoring optimization plan for groundwater monitoring wells associated with the U.S. Department of Energy (DOE) Y-12 National Security Complex (Y-12) in Oak Ridge, Tennessee. The plan describes the technical approach that is implemented under the Y-12 Groundwater Protection Program (GWPP) to focus available resources on the monitoring wells at Y-12 that provide the most useful hydrologic and groundwater quality monitoring data. The technical approach is based on the GWPP status designation for each well. Under this approach, wells granted “active” status are used by the GWPP for hydrologic monitoring and/or groundwater quality sampling, whereas wells grantedmore » “inactive” status are not used for either purpose. The status designation also defines the frequency at which the GWPP will inspect applicable wells, the scope of these well inspections, and extent of any maintenance actions initiated by the GWPP. Details regarding the ancillary activities associated with implementation of this plan (e.g., well inspection) are deferred to the referenced GWPP plans.« less

  19. Quality assurance of reference standards from nine European solar-ultraviolet monitoring laboratories.

    PubMed

    Gröbner, Julian; Rembges, Diana; Bais, Alkiviadis F; Blumthaler, Mario; Cabot, Thierry; Josefsson, Weine; Koskela, Tapani; Thorseth, Trond M; Webb, Ann R; Wester, Ulf

    2002-07-20

    A program for quality assurance of reference standards has been initiated among nine solar-UV monitoring laboratories. By means of a traveling lamp package that comprises several 1000-W ANSI code DXW-type quartz-halogen lamps, a 0.1-ohm shunt, and a 6-1/2 digit voltmeter, the irradiance scales used by the nine laboratories were compared with one another; a relative uncertainty of 1.2% was found. The comparison of 15 reference standards yielded differences of as much as 9%; the average difference was less than 3%.

  20. Ecological Monitoring and Compliance Program Fiscal/Calendar Year 2004 Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bechtel Nevada

    2005-03-01

    The Ecological Monitoring and Compliance program, funded through the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office, monitors the ecosystem of the Nevada Test Site and ensures compliance with laws and regulations pertaining to Nevada Test Site biota. This report summarizes the program's activities conducted by Bechtel Nevada during the Fiscal Year 2004 and the additional months of October, November, and December 2004, reflecting a change in the monitoring period to a calendar year rather than a fiscal year as reported in the past. This change in the monitoring period was made to better accommodate information requiredmore » for the Nevada Test Site Environmental Report, which reports on a calendar year rather than a fiscal year. Program activities included: (1) biological surveys at proposed construction sites, (2) desert tortoise compliance, (3) ecosystem mapping and data management, (4) sensitive species and unique habitat monitoring, (5) habitat restoration monitoring, and (6) biological monitoring at the Hazardous Materials Spill Center.« less

  1. A plan for the North American Bat Monitoring Program (NABat)

    USGS Publications Warehouse

    Loeb, Susan C.; Rodhouse, Thomas J.; Ellison, Laura E.; Lausen, Cori L.; Reichard, Jonathan D.; Irvine, Kathryn M.; Ingersoll, Thomas E.; Coleman, Jeremy; Thogmartin, Wayne E.; Sauer, John R.; Francis, Charles M.; Bayless, Mylea L.; Stanley, Thomas R.; Johnson, Douglas H.

    2015-01-01

    The purpose of the North American Bat Monitoring Program (NABat) is to create a continent-wide program to monitor bats at local to rangewide scales that will provide reliable data to promote effective conservation decisionmaking and the long-term viability of bat populations across the continent. This is an international, multiagency program. Four approaches will be used to gather monitoring data to assess changes in bat distributions and abundances: winter hibernaculum counts, maternity colony counts, mobile acoustic surveys along road transects, and acoustic surveys at stationary points. These monitoring approaches are described along with methods for identifying species recorded by acoustic detectors. Other chapters describe the sampling design, the database management system (Bat Population Database), and statistical approaches that can be used to analyze data collected through this program.

  2. Estuarine monitoring programs in the Albemarle Sound study area, North Carolina

    USGS Publications Warehouse

    Moorman, Michelle; Kolb, Katharine R.; Supak, Stacy

    2014-01-01

    The purpose of this report is to identify major natural resource management issues for the region, provide information on current monitoring activities occurring within the Albemarle Sound study area, determine how the current monitoring network fits into the design of the NMN, and determine what additional monitoring data are needed to address these issues. In order to address these questions, a shapefile and data table were created to document monitoring and research programs in the Albemarle Sound study area with an emphasis on current monitoring programs within the region. This database was queried to determine monitoring gaps that existed in the Albemarle Sound by comparing current monitoring programs with the design indicated by the NMN. The report uses this information to provide recommendations on how monitoring could be improved in the Albemarle Sound study area.

  3. [Study on the optimization of monitoring indicators of drinking water quality during health supervision].

    PubMed

    Ye, Bixiong; E, Xueli; Zhang, Lan

    2015-01-01

    To optimize non-regular drinking water quality indices (except Giardia and Cryptosporidium) of urban drinking water. Several methods including drinking water quality exceed the standard, the risk of exceeding standard, the frequency of detecting concentrations below the detection limit, water quality comprehensive index evaluation method, and attribute reduction algorithm of rough set theory were applied, redundancy factor of water quality indicators were eliminated, control factors that play a leading role in drinking water safety were found. Optimization results showed in 62 unconventional water quality monitoring indicators of urban drinking water, 42 water quality indicators could be optimized reduction by comprehensively evaluation combined with attribute reduction of rough set. Optimization of the water quality monitoring indicators and reduction of monitoring indicators and monitoring frequency could ensure the safety of drinking water quality while lowering monitoring costs and reducing monitoring pressure of the sanitation supervision departments.

  4. 7 CFR 58.141 - Alternate quality control program.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Alternate quality control program. 58.141 Section 58... Service 1 Quality Specifications for Raw Milk § 58.141 Alternate quality control program. When a plant has in operation an acceptable quality program, at the producer level, which is approved by the...

  5. Quality monitored distributed voting system

    DOEpatents

    Skogmo, David

    1997-01-01

    A quality monitoring system can detect certain system faults and fraud attempts in a distributed voting system. The system uses decoy voters to cast predetermined check ballots. Absent check ballots can indicate system faults. Altered check ballots can indicate attempts at counterfeiting votes. The system can also cast check ballots at predetermined times to provide another check on the distributed voting system.

  6. Water Quality Monitor

    NASA Technical Reports Server (NTRS)

    1982-01-01

    An automated water quality monitoring system was developed by Langley Research Center to meet a need of the Environmental Protection Agency (EPA). Designed for unattended operation in water depths up to 100 feet, the system consists of a subsurface buoy anchored in the water, a surface control unit (SCU) and a hydrophone link for acoustic communication between buoy and SCU. Primary functional unit is the subsurface buoy. It incorporates 16 cells for water sampling, plus sensors for eight water quality measurements. Buoy contains all the electronic equipment needed for collecting and storing sensor data, including a microcomputer and a memory unit. Power for the electronics is supplied by a rechargeable nickel cadmium battery that is designed to operate for about two weeks. Through hydrophone link the subsurface buoy reports its data to the SCU, which relays it to land stations. Link allows two-way communications. If system encounters a problem, it automatically shuts down and sends alert signal. Sequence of commands sent via hydrophone link causes buoy to release from anchor and float to the surface for recovery.

  7. R2 Water Quality Portal Monitoring Stations

    EPA Pesticide Factsheets

    The Water Quality Data Portal (WQP) provides an easy way to access data stored in various large water quality databases. The WQP provides various input parameters on the form including location, site, sampling, and date parameters to filter and customize the returned results. The The Water Quality Portal (WQP) is a cooperative service sponsored by the United States Geological Survey (USGS), the Environmental Protection Agency (EPA) and the National Water Quality Monitoring Council (NWQMC) that integrates publicly available water quality data from the USGS National Water Information System (NWIS) the EPA STOrage and RETrieval (STORET) Data Warehouse, and the USDA ARS Sustaining The Earth??s Watersheds - Agricultural Research Database System (STEWARDS).

  8. Santa Margarita Estuary Water Quality Monitoring Data

    DTIC Science & Technology

    2018-02-01

    ADMINISTRATIVE INFORMATION The work described in this report was performed for the Water Quality Section of the Environmental Security Marine Corps Base...water quality model calibration given interest and the necessary resources. The dataset should also inform the stakeholders and Regional Board on...period. Several additional ancillary datasets were collected during the monitoring timeframe that provide key information though they were not collected

  9. Lake Roosevelt Fisheries Monitoring Program; 1988-1989 Annual Report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peone, Tim L.; Scholz, Allan T.; Griffith, James R.

    1990-10-01

    In the Northwest Power Planning Council's 1987 Columbia River Basin Fish and Wildlife Program (NPPC 1987), the Council directed the Bonneville Power Administration (BPA) to construct two kokanee salmon (Oncorhynchus nerka) hatcheries as partial mitigation for the loss of anadromous salmon and steelhead incurred by construction of Grand Coulee Dam [Section 903 (g)(l)(C)]. The hatcheries will produce kokanee salmon for outplanting into Lake Roosevelt as well as rainbow trout (Oncorhynchus mykiss) for the Lake Roosevelt net-pen program. In section 903 (g)(l)(E), the Council also directed BPA to fund a monitoring program to evaluate the effectiveness of the kokanee hatcheries. Themore » monitoring program included the following components: (1) a year-round, reservoir-wide, creel survey to determine angler use, catch rates and composition, and growth and condition of fish; (2) assessment of kokanee, rainbow, and walleye (Stizostedion vitreum) feeding habits and densities of their preferred prey, and; (3) a mark and recapture study designed to assess the effectiveness of different locations where hatchery-raised kokanee and net pen reared rainbow trout are released. The above measures were adopted by the Council based on a management plan, developed by the Upper Columbia United Tribes Fisheries Center, Spokane Indian Tribe, Colville Confederated Tribes, Washington Department of Wildlife, and National Park Service, that examined the feasibility of restoring and enhancing Lake Roosevelt fisheries (Scholz et al. 1986). In July 1988, BPA entered into a contract with the Spokane Indian Tribe to initiate the monitoring program. The projected duration of the monitoring program is through 1995. This report contains the results of the monitoring program from August 1988 to December 1989.« less

  10. Monitoring Quality Across Home Visiting Models: A Field Test of Michigan's Home Visiting Quality Assurance System.

    PubMed

    Heany, Julia; Torres, Jennifer; Zagar, Cynthia; Kostelec, Tiffany

    2018-06-05

    Introduction In order to achieve the positive outcomes with parents and children demonstrated by many home visiting models, home visiting services must be well implemented. The Michigan Home Visiting Initiative developed a tool and procedure for monitoring implementation quality across models referred to as Michigan's Home Visiting Quality Assurance System (MHVQAS). This study field tested the MHVQAS. This article focuses on one of the study's evaluation questions: Can the MHVQAS be applied across models? Methods Eight local implementing agencies (LIAs) from four home visiting models (Healthy Families America, Early Head Start-Home Based, Parents as Teachers, Maternal Infant Health Program) and five reviewers participated in the study by completing site visits, tracking their time and costs, and completing surveys about the process. LIAs also submitted their most recent review by their model developer. The researchers conducted participant observation of the review process. Results Ratings on the MHVQAS were not significantly different between models. There were some differences in interrater reliability and perceived reliability between models. There were no significant differences between models in perceived validity, satisfaction with the review process, or cost to participate. Observational data suggested that cross-model applicability could be improved by assisting sites in relating the requirements of the tool to the specifics of their model. Discussion The MHVQAS shows promise as a tool and process to monitor implementation quality of home visiting services across models. The results of the study will be used to make improvements before the MHVQAS is used in practice.

  11. Application of ion-sensitive sensors in water quality monitoring.

    PubMed

    Winkler, S; Rieger, L; Saracevic, E; Pressl, A; Gruber, G

    2004-01-01

    Within the last years a trend towards in-situ monitoring can be observed, i.e. most new sensors for water quality monitoring are designed for direct installation in the medium, compact in size and use measurement principles which minimise maintenance demand. Ion-sensitive sensors (Ion-Sensitive-Electrode--ISE) are based on a well known measurement principle and recently some manufacturers have released probe types which are specially adapted for application in water quality monitoring. The function principle of ISE-sensors, their advantages, limitations and the different methods for sensor calibration are described. Experiences with ISE-sensors from applications in sewer networks, at different sampling points within wastewater treatment plants and for surface water monitoring are reported. An estimation of investment and operation costs in comparison to other sensor types is given.

  12. Monitoring water quality in a hypereutrophic reservoir using Landsat ETM+ and OLI sensors: how transferable are the water quality algorithms?

    PubMed

    Deutsch, Eliza S; Alameddine, Ibrahim; El-Fadel, Mutasem

    2018-02-15

    The launch of the Landsat 8 in February 2013 extended the life of the Landsat program to over 40 years, increasing the value of using Landsat to monitor long-term changes in the water quality of small lakes and reservoirs, particularly in poorly monitored freshwater systems. Landsat-based water quality hindcasting often incorporate several Landsat sensors in an effort to increase the temporal range of observations; yet the transferability of water quality algorithms across sensors remains poorly examined. In this study, several empirical algorithms were developed to quantify chlorophyll-a, total suspended matter (TSM), and Secchi disk depth (SDD) from surface reflectance measured by Landsat 7 ETM+ and Landsat 8 OLI sensors. Sensor-specific multiple linear regression models were developed by correlating in situ water quality measurements collected from a semi-arid eutrophic reservoir with band ratios from Landsat ETM+ and OLI sensors, along with ancillary data (water temperature and seasonality) representing ecological patterns in algae growth. Overall, ETM+-based models outperformed (adjusted R 2 chlorophyll-a = 0.70, TSM = 0.81, SDD = 0.81) their OLI counterparts (adjusted R 2 chlorophyll-a = 0.50, TSM = 0.58, SDD = 0.63). Inter-sensor differences were most apparent for algorithms utilizing the Blue spectral band. The inclusion of water temperature and seasonality improved the power of TSM and SDD models.

  13. Critical loads and levels: Leveraging existing monitoring data

    Treesearch

    D. G. Fox; A. R. Riebau; R. Fisher

    2006-01-01

    A snapshot of current air quality in the National Parks and Wilderness areas of the US is presented based on data from the 165 site Interagency Monitoring of Protected Visual Environments, or IMPROVE program, and other relevant air quality monitoring programs. This snapshot is provided using the VIEWS web service, an on-line web-based data warehouse, analysis, and...

  14. [Research advances in water quality monitoring technology based on UV-Vis spectrum analysis].

    PubMed

    Wei, Kang-Lin; Wen, Zhi-yu; Wu, Xin; Zhang, Zhong-Wei; Zeng, Tian-Ling

    2011-04-01

    The application of spectral analysis to water quality monitoring is an important developing trend in the field of modern environment monitoring technology. The principle and characteristic of water quality monitoring technology based on UV-Vis spectrum analysis are briefly reviewed. And the research status and advances are introduced from two aspects, on-line monitoring and in-situ monitoring. Moreover, the existent key technical problems are put forward. Finally, the technology trends of multi-parameter water quality monitoring microsystem and microsystem networks based on microspectrometer are prospected, which has certain reference value for the research and development of environmental monitoring technology and modern scientific instrument in the authors' country.

  15. A plan for the North American Bat Monitoring Program (NABat)

    Treesearch

    Susan C. Loeb; Thomas J. Rodhouse; Laura E. Ellison; Cori L. Lausen; Jonathan D. Reichard; Kathryn M. Irvine; Thomas E. Ingersoll; Jeremy T.H. Coleman; Wayne E. Thogmartin; John R. Sauer; Charles M. Francis; Mylea L. Bayless; Thomas R. Stanley; Douglas H. Johnson

    2015-01-01

    The purpose of the North American Bat Monitoring Program (NABat) is to create a continent-wide program to monitor bats at local to rangewide scales that will provide reliable data to promote effective conservation decisionmaking and the long-term viability of bat populations across the continent. This is an international, multiagency program. Four approaches will be...

  16. Application of two quality indices as monitoring and management tools of rivers. Case study: the Imera Meridionale River, Italy.

    PubMed

    Bonanno, Giuseppe; Lo Giudice, Rosa

    2010-04-01

    On the basis of the European Water Framework Directive (2000/60), the water resources of the member states of the European Community should reach good quality standards by 2015. Although such regulations illustrate the basic points for a comprehensive and effective policy of water monitoring and management, no practical tools are provided to face and solve the issues concerning freshwater ecosystems such as rivers. The Italian government has developed a set of regulations as adoption of the European Directive but failed to indicate feasible procedures for river monitoring and management. On a local scale, Sicilian authorities have implemented monitoring networks of watersheds, aiming at describing the general conditions of rivers. However, such monitoring programs have provided a relatively fragmentary picture of the ecological conditions of the rivers. In this study, the integrated use of environmental quality indices is proposed as a methodology able to provide a practical approach to river monitoring and management. As a case study, the Imera Meridionale River, Sicily's largest river, was chosen. The water quality index developed by the U.S. National Sanitation Foundation and the floristic quality index based on the Wilhelm method were applied. The former enabled us to describe the water quality according to a spatial-temporal gradient, whereas the latter focused on the ecological quality of riparian vegetation. This study proposes a holistic view of river ecosystems by considering biotic and abiotic factors in agreement with the current European regulations. How the combined use of such indices can guide sustainable management efforts is also discussed.

  17. Overview of four prescription monitoring/review programs in Canada.

    PubMed

    Furlan, Andrea D; MacDougall, Peter; Pellerin, Denise; Shaw, Karen; Spitzig, Doug; Wilson, Galt; Wright, Janet

    2014-01-01

    Prescription monitoring or review programs collect information about prescription and dispensing of controlled substances for the purposes of monitoring, analysis and education. In Canada, it is the responsibility of the provincial institutions to organize, maintain and run such programs. To describe the characteristics of four provincial programs that have been in place for >6 years. The managers of the prescription monitoring⁄review programs of four provinces (British Columbia, Alberta, Saskatchewan and Nova Scotia) were invited to present at a symposium at the Canadian Pain Society in May 2012. In preparation for the symposium, one author collected and summarized the information. Three provinces have a mix of review and monitoring programs; the program in British Columbia is purely for review and education. All programs include controlled substances (narcotics, barbiturates and psychostimulants); however, other substances are differentially included among the programs: anabolic steroids are included in Saskatchewan and Nova Scotia; and cannabinoids are included in British Columbia and Nova Scotia. Access to the database is available to pharmacists in all provinces. Physicians need consent from patients in British Columbia, and only professionals registered with the program can access the database in Alberta. The definition of inappropriate prescribing and dispensing is not uniform. Double doctoring, double pharmacy and high-volume dispensing are considered to be red flags in all programs. There is variability among Canadian provinces in managing prescription monitoring⁄review programs.

  18. Automated size-specific CT dose monitoring program: Assessing variability in CT dose

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christianson, Olav; Li Xiang; Frush, Donald

    2012-11-15

    estimates that were not adjusted by patient size. Additionally, considerable differences were noted in ED{sub adj} distributions between scanners, with scanners employing iterative reconstruction exhibiting significantly lower ED{sub adj} (range: 9%-64%). Finally, a significant difference (up to 59%) in ED{sub adj} distributions was observed between institutions, indicating the potential for dose reduction. Conclusions: The authors developed a robust automated size-specific radiation dose monitoring program for CT. Using this program, significant differences in ED{sub adj} were observed between scanner models and across institutions. This new dose monitoring program offers a unique tool for improving quality assurance and standardization both within and across institutions.« less

  19. Monitoring multiple species: Estimating state variables and exploring the efficacy of a monitoring program

    USGS Publications Warehouse

    Mattfeldt, S.D.; Bailey, L.L.; Grant, E.H.C.

    2009-01-01

    Monitoring programs have the potential to identify population declines and differentiate among the possible cause(s) of these declines. Recent criticisms regarding the design of monitoring programs have highlighted a failure to clearly state objectives and to address detectability and spatial sampling issues. Here, we incorporate these criticisms to design an efficient monitoring program whose goals are to determine environmental factors which influence the current distribution and measure change in distributions over time for a suite of amphibians. In designing the study we (1) specified a priori factors that may relate to occupancy, extinction, and colonization probabilities and (2) used the data collected (incorporating detectability) to address our scientific questions and adjust our sampling protocols. Our results highlight the role of wetland hydroperiod and other local covariates in the probability of amphibian occupancy. There was a change in overall occupancy probabilities for most species over the first three years of monitoring. Most colonization and extinction estimates were constant over time (years) and space (among wetlands), with one notable exception: local extinction probabilities for Rana clamitans were lower for wetlands with longer hydroperiods. We used information from the target system to generate scenarios of population change and gauge the ability of the current sampling to meet monitoring goals. Our results highlight the limitations of the current sampling design, emphasizing the need for long-term efforts, with periodic re-evaluation of the program in a framework that can inform management decisions.

  20. Dynamic Analyses of Result Quality in Energy-Aware Approximate Programs

    NASA Astrophysics Data System (ADS)

    RIngenburg, Michael F.

    Energy efficiency is a key concern in the design of modern computer systems. One promising approach to energy-efficient computation, approximate computing, trades off output precision for energy efficiency. However, this tradeoff can have unexpected effects on computation quality. This thesis presents dynamic analysis tools to study, debug, and monitor the quality and energy efficiency of approximate computations. We propose three styles of tools: prototyping tools that allow developers to experiment with approximation in their applications, online tools that instrument code to determine the key sources of error, and online tools that monitor the quality of deployed applications in real time. Our prototyping tool is based on an extension to the functional language OCaml. We add approximation constructs to the language, an approximation simulator to the runtime, and profiling and auto-tuning tools for studying and experimenting with energy-quality tradeoffs. We also present two online debugging tools and three online monitoring tools. The first online tool identifies correlations between output quality and the total number of executions of, and errors in, individual approximate operations. The second tracks the number of approximate operations that flow into a particular value. Our online tools comprise three low-cost approaches to dynamic quality monitoring. They are designed to monitor quality in deployed applications without spending more energy than is saved by approximation. Online monitors can be used to perform real time adjustments to energy usage in order to meet specific quality goals. We present prototype implementations of all of these tools and describe their usage with several applications. Our prototyping, profiling, and autotuning tools allow us to experiment with approximation strategies and identify new strategies, our online tools succeed in providing new insights into the effects of approximation on output quality, and our monitors succeed in

  1. Monitoring Ground-Water Quality in Coastal Ecosystems

    USGS Publications Warehouse

    Colman, John A.; Masterson, John P.

    2007-01-01

    INTRODUCTION The Cape Cod National Seashore (CACO) extends along more than 70 km of Atlantic Ocean open-beach coastline and includes three large saltwater bays - Wellfleet Harbor, Nauset Marsh, and Pleasant Bay (fig. 1). CACO encompasses about 18,000 ha of uplands, lakes, wetlands, and tidal lands (Godfrey and others, 1999) including most habitats typical of the sandy coast in National seashores and parks extending southward from Massachusetts to Florida. In 1995, CACO was selected by the National Park Service (NPS) as a prototype park typifying the Atlantic and Gulf Coast biogeographic region for long-term coastal ecosystem monitoring. The U.S. Geological Survey (USGS) is currently (2007) assisting the NPS in the development of protocols for a Long-Term Coastal Ecosystem Monitoring Program at the CACO in Massachusetts. The overall purpose of the monitoring program is to characterize both natural and human-induced change in the biological resources of the CACO, over a time scale of decades, in the context of a changing global ecosystem.

  2. Quality monitored distributed voting system

    DOEpatents

    Skogmo, D.

    1997-03-18

    A quality monitoring system can detect certain system faults and fraud attempts in a distributed voting system. The system uses decoy voters to cast predetermined check ballots. Absent check ballots can indicate system faults. Altered check ballots can indicate attempts at counterfeiting votes. The system can also cast check ballots at predetermined times to provide another check on the distributed voting system. 6 figs.

  3. Rationale for Quality Assurance in Fecal Egg Monitoring of Soil-Transmitted Helminthiasis

    PubMed Central

    Hoekendijk, David J. L.; Hill, Philip C.; Sowerby, Stephen J.

    2016-01-01

    Substantial investment has been made into the once “neglected” tropical disease, soil-transmitted helminthiasis, and into control programs that operate within a framework of mapping baseline disease distribution, measuring the effectiveness of applied interventions, establishing when to cease drug administration, and for posttreatment evaluations. However, critical to each of these stages is the determination of helminth infection. The limitations of traditional microscope-based fecal egg diagnostics have not provided quality assurance in the monitoring of parasite disease and suboptimal treatment regimes provide for the potential development of parasite resistance to anthelmintic drugs. Improved diagnostic and surveillance tools are required to protect therapeutic effectiveness and to maintain funder confidence. Such tools may be on the horizon with emergent technologies that offer potential for enhanced visualization and quality-assured quantitation of helminth eggs. PMID:27352875

  4. Application of quality risk management to set viable environmental monitoring frequencies in biotechnology processing and support areas.

    PubMed

    Sandle, Tim

    2012-01-01

    Environmental monitoring programs are essential for pharmaceutical facilities in order to assess the level of environmental control. For biotechnology facilities there is little advice as to the frequency at which viable environmental monitoring should be conducted. This paper outlines an approach, based on the principles of quality risk management, for the development of a framework from which monitoring frequencies can be determined. This involved the identification of common hazards and the evaluation those hazards in terms of the severity of contamination and the probability of contamination occurring. These elements of risk were evaluated for different cleanrooms and the relative risks ranked. Once the risk scores were calculated, the methods for detecting risks within the cleanrooms were assessed. Risk filtering was then used to group different cleanrooms based on their relative risks and detection methods against predetermined monitoring frequencies. Through use of case study examples, the paper presents the model and describes how appropriate frequencies for the environmental monitoring of cleanrooms can be set. Cleanrooms in which biotechnology pharmaceutical processing takes place are subject to environmental monitoring. The frequency at which such monitoring should be performed can be difficult to determine. This paper uses quality risk assessment methods to construct a framework for determining monitoring frequencies and illustrates the suitability of the framework through a case study.

  5. Monitoring ecosystem quality and function in arid settings of the Mojave Desert

    USGS Publications Warehouse

    Belnap, Jayne; Webb, Robert H.; Miller, Mark E.; Miller, David M.; DeFalco, Lesley A.; Medica, Philip A.; Brooks, Matthew L.; Esque, Todd C.; Bedford, Dave

    2008-01-01

    Monitoring ecosystem quality and function in the Mojave Desert is both a requirement of state and Federal government agencies and a means for determining potential long-term changes induced by climatic fluctuations and land use. Because it is not feasible to measure every attribute and process in the desert ecosystem, the choice of what to measure and where to measure it is the most important starting point of any monitoring program. In the Mojave Desert, ecosystem function is strongly influenced by both abiotic and biotic factors, and an understanding of the temporal and spatial variability induced by climate and landform development is needed to determine where site-specific measurements should be made. We review a wide variety of techniques for sampling, assessing, and measuring climatic variables, desert soils, biological soil crusts, annual and perennial vegetation, reptiles, and small mammals. The complete array of ecosystem attributes and processes that we describe are unlikely to be measured or monitored at any given location, but the array of possibilities allows for the development of specific monitoring protocols, which can be tailored to suit the needs of land-management agencies.

  6. 77 FR 18709 - Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-28

    ... Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources AGENCY... direct final rule titled ``Quality Assurance Requirements for Continuous Opacity Monitoring Systems at...--Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources Docket, EPA...

  7. Osteopathic postdoctoral training institutions: a decentralized model for facilitating accreditation and program quality.

    PubMed

    Peska, Don N; Opipari, Michael I; Watson, D Keith

    2009-06-01

    Osteopathic medicine has experienced significant growth in the number of accredited colleges and graduates over the past decade. Anticipating that growth and recognizing a responsibility to provide sufficient opportunities for quality postdoctoral training, the American Osteopathic Association created a national network of educational consortia to meet the needs of those graduates. These osteopathic postdoctoral training institutions (OPTIs) were to provide enhanced capability for the development and accreditation of new programs, quality oversight, and access to academic resources for their members. The plan reached full implementation in 1999 when all graduate training programs were required to become members of one of these consortia. Although several contributing factors can be considered, an increase in the rate at which training programs have obtained approval by the American Osteopathic Association has occurred under the OPTI model. Quality indicators are more elusive. Each OPTI provides peer-driven oversight to curriculum and faculty development and closely monitors outcomes such as in-service examination scores, certification board passage rates, and resident evaluations of programs.The strategy has enabled a much-sought-after transformation in osteopathic graduate medical education that has provided both strength and accountability to the preexisting infrastructure. As a decentralized accreditation model, OPTI is still evolving and warrants continued application and study.

  8. Louisiana Barrier Island Comprehensive Monitoring (BICM) Program Summary Report: Data and Analyses 2006 through 2010

    USGS Publications Warehouse

    Kindinger, Jack G.; Buster, Noreen A.; Flocks, James G.; Bernier, Julie C.; Kulp, Mark A.

    2013-01-01

    broader coastal context: (1) barrier-shoreline evolution driven by rapid relative sea-level rise (RSLR), (2) hurricane impacts to the Chandeleur Islands and likelihood of island recovery, (3) impact of tropical storms on barrier shorelines, (4) Barataria Bay tidal-inlet management, and (5) habitat changes related to RSLR. The final theme addresses potential future goals of the BICM program, including rotational annual to semi-decadal monitoring, proposed new-data collection, how to incorporate technological advances with previous data-collection and monitoring protocols, and standardizing methods and quality-control assessments for continued coastal monitoring and restoration.

  9. Floristic Quality Index: An assessment tool for restoration projects and monitoring sites in coastal Louisiana

    USGS Publications Warehouse

    Cretini, K.F.; Steyer, G.D.

    2011-01-01

    The Coastwide Reference Monitoring System (CRMS) program was established to assess the effectiveness of individual coastal restoration projects and the cumulative effects of multiple projects at regional and coastwide scales. In order to make these assessments, analytical teams have been assembled for each of the primary data types sampled under the CRMS program, including vegetation, hydrology, landscape, and soils. These teams consist of scientists and support staff from the U.S. Geological Survey and other Federal agencies, the Louisiana Office of Coastal Protection and Restoration, and university academics. Each team is responsible for developing or identifying parameters, indices, or tools that can be used to assess coastal wetlands at various scales. The CRMS Vegetation Analytical Team has developed a Floristic Quality Index for coastal Louisiana to determine the quality of a wetland based on its plant species composition and abundance.

  10. Advances in recreational water quality monitoring at Indiana Dunes National Lakeshore

    USGS Publications Warehouse

    Smith, Wendy; Nevers, Meredith; Whitman, Richard L.

    2006-01-01

    Indiana Dunes has improved its ability to protect the health of swimmers through better science-based management and increased understanding of contaminants. Most research has focused on Escherichia coli and its nature, sources, and distribution because it is widely accepted as an indicator of potential pathogens. Though research on E. coli and recreational water quality is continually generating new information, public beach managers may gain valuable insight into this management issue from our experience at Indiana Dunes. This article reviews one of the longest maintained indicator bacteria monitoring programs in the National Park System, highlights lessons learned, and summarizes research findings that may be of interest to public beach managers.

  11. 18 CFR 12.40 - Quality control programs.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false Quality control... PROJECT WORKS Other Responsibilities of Applicant or Licensee § 12.40 Quality control programs. (a... meeting any requirements or standards set by the Regional Engineer. If a quality control program is...

  12. 18 CFR 12.40 - Quality control programs.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Quality control... PROJECT WORKS Other Responsibilities of Applicant or Licensee § 12.40 Quality control programs. (a... meeting any requirements or standards set by the Regional Engineer. If a quality control program is...

  13. 10 CFR 71.105 - Quality assurance program.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Quality assurance program. 71.105 Section 71.105 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) PACKAGING AND TRANSPORTATION OF RADIOACTIVE MATERIAL Quality Assurance § 71.105 Quality assurance program. (a) The licensee, certificate holder, and applicant for a CoC...

  14. Overview of the new National Near-Road Air Quality Monitoring Network

    EPA Science Inventory

    In 2010, EPA promulgated new National Ambient Air Quality Standards (NAAQS) for nitrogen dioxide (NO2). As part of this new NAAQS, EPA required the establishment of a national near-road air quality monitoring network. This network will consist of one NO2 near-road monitoring st...

  15. A synthesis of evaluation monitoring projects by the forest health monitoring program (1998-2007)

    Treesearch

    William A. Bechtold; Michael J. Bohne; Barbara L. Conkling; Dana L. Friedman

    2012-01-01

    The national Forest Health Monitoring Program of the Forest Service, U.S. Department of Agriculture, has funded over 200 Evaluation Monitoring projects. Evaluation Monitoring is designed to verify and define the extent of deterioration in forest ecosystems where potential problems have been identified. This report is a synthesis of results from over 150 Evaluation...

  16. Groundwater-quality and quality-control data for two monitoring wells near Pavillion, Wyoming, April and May 2012

    USGS Publications Warehouse

    Wright, Peter R.; McMahon, Peter B.; Mueller, David K.; Clark, Melanie L.

    2012-01-01

    In June 2010, the U.S. Environmental Protection Agency installed two deep monitoring wells (MW01 and MW02) near Pavillion, Wyoming, to study groundwater quality. During April and May 2012, the U.S Geological Survey, in cooperation with the Wyoming Department of Environmental Quality, collected groundwater-quality data and quality-control data from monitoring well MW01 and, following well redevelopment, quality-control data for monitoring well MW02. Two groundwater-quality samples were collected from well MW01—one sample was collected after purging about 1.5 borehole volumes, and a second sample was collected after purging 3 borehole volumes. Both samples were collected and processed using methods designed to minimize atmospheric contamination or changes to water chemistry. Groundwater-quality samples were analyzed for field water-quality properties (water temperature, pH, specific conductance, dissolved oxygen, oxidation potential); inorganic constituents including naturally occurring radioactive compounds (radon, radium-226 and radium-228); organic constituents; dissolved gasses; stable isotopes of methane, water, and dissolved inorganic carbon; and environmental tracers (carbon-14, chlorofluorocarbons, sulfur hexafluoride, tritium, helium, neon, argon, krypton, xenon, and the ratio of helium-3 to helium-4). Quality-control sample results associated with well MW01 were evaluated to determine the extent to which environmental sample analytical results were affected by bias and to evaluate the variability inherent to sample collection and laboratory analyses. Field documentation, environmental data, and quality-control data for activities that occurred at the two monitoring wells during April and May 2012 are presented.

  17. [Electronic fetal monitoring and management of adverse outcomes: how to perform and improve a training program for clinicians?].

    PubMed

    Secourgeon, J-F

    2012-10-01

    Electronic fetal monitoring during labor is the most commonly used method to evaluate the fetal status, but it remains exposed to some criticism. By comparison with intermittent auscultation and in the light of the results of the great studies in the last 30 years, it may be accused its failure to improve the neonatal outcome and its responsibility in the increase on operative deliveries. Actually, the electronic fetal monitoring is a tool whose effectiveness is linked to the accuracy of the analysis developed by the clinician. Studies on assessment of the tracing interpretation indicate that there is always a lack of quality, which may be improved through training programs. It also reveals the benefit of the fetal blood sampling to reduce operative deliveries and the generalization of this method, in addition to electronic fetal monitoring, is recommended by referral agencies. More generally, the continuous monitoring is only a part of the patient safety strategy in the labour ward and we are currently observing, in some European countries and in the United States, the development of training programs concerning the management of the adverse outcomes in obstetrics. The good performances related to the quality of care are demonstrated by the findings of the studies performed in the centers that have implemented an active training policy. In France, the professionals directly involved in the field of the perinatology should benefit from such educational programs that could be organized within the care networks under the authority of referral agencies. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  18. Wastewater quality monitoring system using sensor fusion and machine learning techniques.

    PubMed

    Qin, Xusong; Gao, Furong; Chen, Guohua

    2012-03-15

    A multi-sensor water quality monitoring system incorporating an UV/Vis spectrometer and a turbidimeter was used to monitor the Chemical Oxygen Demand (COD), Total Suspended Solids (TSS) and Oil & Grease (O&G) concentrations of the effluents from the Chinese restaurant on campus and an electrocoagulation-electroflotation (EC-EF) pilot plant. In order to handle the noise and information unbalance in the fused UV/Vis spectra and turbidity measurements during the calibration model building, an improved boosting method, Boosting-Iterative Predictor Weighting-Partial Least Squares (Boosting-IPW-PLS), was developed in the present study. The Boosting-IPW-PLS method incorporates IPW into boosting scheme to suppress the quality-irrelevant variables by assigning small weights, and builds up the models for the wastewater quality predictions based on the weighted variables. The monitoring system was tested in the field with satisfactory results, underlying the potential of this technique for the online monitoring of water quality. Copyright © 2011 Elsevier Ltd. All rights reserved.

  19. Water quality monitor. [spacecraft potable water

    NASA Technical Reports Server (NTRS)

    West, S.; Crisos, J.; Baxter, W.

    1979-01-01

    The preprototype water quality monitor (WQM) subsystem was designed based on a breadboard monitor for pH, specific conductance, and total organic carbon (TOC). The breadboard equipment demonstrated the feasibility of continuous on-line analysis of potable water for a spacecraft. The WQM subsystem incorporated these breadboard features and, in addition, measures ammonia and includes a failure detection system. The sample, reagent, and standard solutions are delivered to the WQM sensing manifold where chemical operations and measurements are performed using flow through sensors for conductance, pH, TOC, and NH3. Fault monitoring flow detection is also accomplished in this manifold assembly. The WQM is designed to operate automatically using a hardwired electronic controller. In addition, automatic shutdown is incorporated which is keyed to four flow sensors strategically located within the fluid system.

  20. Quality assurance program for isotopic power systems

    NASA Astrophysics Data System (ADS)

    Hannigan, R. L.; Harnar, R. R.

    1982-12-01

    The Sandia National Laboratories Quality Assurance Program that applies to non-weapon (reimbursable) Radioisotopic Thermoelectric Generators is summarized. The program was implemented over the past 16 years on power supplies used in various space and terrestrial systems. The quality assurance (QA) activity of the program is in support of the Department of Energy, Office of Space Nuclear Projects. Basic elements of the program are described and examples of program documentation are presented.

  1. 10 CFR 72.144 - Quality assurance program.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Quality assurance program. 72.144 Section 72.144 Energy... NUCLEAR FUEL, HIGH-LEVEL RADIOACTIVE WASTE, AND REACTOR-RELATED GREATER THAN CLASS C WASTE Quality Assurance § 72.144 Quality assurance program. (a) The licensee, applicant for a license, certificate holder...

  2. Quality Enhancement: An Overview. Program Services Papers.

    ERIC Educational Resources Information Center

    North Carolina Partnership for Children, Raleigh.

    Leading a series of in-depth technical assistance papers on improving the quality in early care and education programs, this brochure is designed to help local communities consider the most effective strategies in designing and implementing programs that improve child care quality. A quality enhancement approach is taken whereby communities begin…

  3. Water Quality Sensing and Spatio-Temporal Monitoring Structure with Autocorrelation Kernel Methods.

    PubMed

    Vizcaíno, Iván P; Carrera, Enrique V; Muñoz-Romero, Sergio; Cumbal, Luis H; Rojo-Álvarez, José Luis

    2017-10-16

    Pollution on water resources is usually analyzed with monitoring campaigns, which consist of programmed sampling, measurement, and recording of the most representative water quality parameters. These campaign measurements yields a non-uniform spatio-temporal sampled data structure to characterize complex dynamics phenomena. In this work, we propose an enhanced statistical interpolation method to provide water quality managers with statistically interpolated representations of spatial-temporal dynamics. Specifically, our proposal makes efficient use of the a priori available information of the quality parameter measurements through Support Vector Regression (SVR) based on Mercer's kernels. The methods are benchmarked against previously proposed methods in three segments of the Machángara River and one segment of the San Pedro River in Ecuador, and their different dynamics are shown by statistically interpolated spatial-temporal maps. The best interpolation performance in terms of mean absolute error was the SVR with Mercer's kernel given by either the Mahalanobis spatial-temporal covariance matrix or by the bivariate estimated autocorrelation function. In particular, the autocorrelation kernel provides with significant improvement of the estimation quality, consistently for all the six water quality variables, which points out the relevance of including a priori knowledge of the problem.

  4. Evaluation of the US Army Institute of Public Health Destination Monitoring Program, a food safety surveillance program.

    PubMed

    Rapp-Santos, Kamala; Havas, Karyn; Vest, Kelly

    2015-01-01

    The Destination Monitoring Program, operated by the US Army Public Health Command (APHC), is one component that supports the APHC Veterinary Service's mission to ensure safety and quality of food procured for the Department of Defense (DoD). This program relies on retail product testing to ensure compliance of production facilities and distributors that supply food to the DoD. This program was assessed to determine the validity and timeliness by specifically evaluating whether sample size of items collected was adequate, if food samples collected were representative of risk, and whether the program returns results in a timely manner. Data was collected from the US Army Veterinary Services Lotus Notes database, including all food samples collected and submitted from APHC Region-North for the purposes of destination monitoring from January 1, 2013 to December 31, 2013. For most food items, only one sample was submitted for testing. The ability to correctly identify a contaminated food lot may be limited by reliance on test results from only one sample, as the level of confidence in a negative test result is low. The food groups most frequently sampled by APHC correlated with the commodities that were implicated in foodborne illness in the United States. Food items to be submitted were equally distributed among districts and branches, but sections within large branches submitted relatively few food samples compared to sections within smaller branches and districts. Finally, laboratory results were not available for about half the food items prior to their respective expiration dates.

  5. USGS Zebra Mussel Monitoring Program for north Texas

    USGS Publications Warehouse

    Churchill, Christopher J.; Baldys, Stanley

    2012-01-01

    The U.S. Geological Survey (USGS) Zebra Mussel Monitoring Program for north Texas provides early detection and monitoring of zebra mussels (Dreissena polymorpha) by using a holistic suite of detection methods. The program is designed to assess zebra mussel occurrence, distribution, and densities in north Texas waters by using four approaches: (1) SCUBA diving, (2) water-sample collection with plankton tow nets (followed by laboratory analyses), (3) artificial substrates, and (4) water-quality sampling. Data collected during this type of monitoring can assist rapid response efforts and can be used to quantify the economic and ecological effects of zebra mussels in the north Texas area. Monitoring under this program began in April 2010. The presence of large zebra mussel populations often causes undesirable economic and ecological effects, including damage to water-processing infrastructure and hydroelectric powerplants (with an estimated 10-year cost of $3.1 billion), displacement of native mussels, increases in concentrations of certain species of cyanobacteria, and increases in concentrations of geosmin (an organic compound that results in taste and odor issues in water). Since no large-scale, environmentally safe eradication method has been developed for zebra mussels, it is difficult to remove established populations. Broad physicochemical adaptability, prolific reproductive capacity, and rapid dispersal methods have enabled zebra mussels, within a period of about 20 years, to establish populations under differing environmental conditions across much of the eastern part of the United States. In Texas, the presence of zebra mussels was first confirmed in April 2009 in Lake Texoma in the Red River Basin along the Texas-Oklahoma border. They were most likely introduced into Lake Texoma through overland transport from an infested water body. Since then, the presence of zebra mussels has been reported in both the Red River and Washita River arms of Lake Texoma, in

  6. Fuzzy intelligent quality monitoring model for X-ray image processing.

    PubMed

    Khalatbari, Azadeh; Jenab, Kouroush

    2009-01-01

    Today's imaging diagnosis needs to adapt modern techniques of quality engineering to maintain and improve its accuracy and reliability in health care system. One of the main factors that influences diagnostic accuracy of plain film X-ray on detecting pathology is the level of film exposure. If the level of film exposure is not adequate, a normal body structure may be interpretated as pathology and vice versa. This not only influences the patient management but also has an impact on health care cost and patient's quality of life. Therefore, providing an accurate and high quality image is the first step toward an excellent patient management in any health care system. In this paper, we study these techniques and also present a fuzzy intelligent quality monitoring model, which can be used to keep variables from degrading the image quality. The variables derived from chemical activity, cleaning procedures, maintenance, and monitoring may not be sensed, measured, or calculated precisely due to uncertain situations. Therefore, the gamma-level fuzzy Bayesian model for quality monitoring of an image processing is proposed. In order to apply the Bayesian concept, the fuzzy quality characteristics are assumed as fuzzy random variables. Using the fuzzy quality characteristics, the newly developed model calculates the degradation risk for image processing. A numerical example is also presented to demonstrate the application of the model.

  7. Weatherization and Indoor Air Quality: Measured Impacts in Single Family Homes Under the Weatherization Assistance Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pigg, Scott; Cautley, Dan; Francisco, Paul

    2014-09-01

    This report summarizes findings from a national field study of indoor air quality parameters in homes treated under the Weatherization Assistance Program (WAP). The study involved testing and monitoring in 514 single-family homes (including mobile homes) located in 35 states and served by 88 local weatherization agencies.

  8. Overview of national bird population monitoring programs and databases

    Treesearch

    Gregory S. Butcher; Bruce Peterjohn; C. John Ralph

    1993-01-01

    A number of programs have been set up to monitor populations of nongame migratory birds. We review these programs and their purposes and provide information on obtaining data or results from these programs. In addition, we review recommendations for improving these programs.

  9. Emblems of Quality in Higher Education. Developing and Sustaining High-Quality Programs.

    ERIC Educational Resources Information Center

    Haworth, Jennifer Grant; Conrad, Clifton F.

    This book proposes an "engagement" theory of program quality to evaluate and improve higher education programs at all degree levels. Based on interviews with 781 participants in a national study of Masters degree programs, it focuses on the interactive roles of students, faculty, and administrators in developing high-quality programs…

  10. [Family physicians attitude towards quality indicator program].

    PubMed

    Shani, Michal; Nakar, Sasson; Azuri, Yossi

    2012-10-01

    Quality indicator programs for primary care are implanted throughout the world improving quality in health care. In this study, we have assessed family physicians attitudes towards the quality indicators program in Israel. Questionnaires were distributed to family physicians in various continuing educational programs. The questionnaire addressed demographics, whether the physician dealt with quality indicators, time devoted by the physician to quality indicators, pressure placed on the physician related to quality indicators, and the working environment. A total of 140 questionnaires were distributed and 91 (65%) were completed. The average physician age was 49 years (range 33-65 years]; the average working experience as a family physician was 17.8 years (range 0.5-42); 58 physicians were family medicine specialist (65.9%). Quality indicators were part of the routine work of 94% of the physicians; 72% of the physicians noted the importance of quality indicators; 84% of the physicians noted that quality indicators demand better team work; 76% of the physicians noted that quality indicators have reduced their professional independence. Pressure to deal with quality indicators was noted by 72% of the family physicians. Pressure to deal with quality indicators was related to reduced loyalty to their employer (P = 0.001), reducing their interest to practice family medicine (p < 0.001), and increasing their burnout at work (p = 0.001). It is important that policy makers find the way to leverage the advantages of quality indicator programs, without creating a heavy burden on the work of family physicians.

  11. Quality of pancreatic transplant program assessment using a risk-adjusted cumulative sum chart: experience from a single, small center.

    PubMed

    Grochowiecki, T; Jakimowicz, T; Grabowska-Derlatka, L; Szmidt, J

    2014-10-01

    The high rate of complication after pancreas transplantation not only had an impact on recipient quality of life and survival but also had significant financial implications. Thus, monitoring transplant center performance was crucial to indentifying changes in clinical practice that result in quality deterioration. To evaluate retrospectively the quality of the single, small pancreatic transplant program and to establish prospective monitoring of the center using risk-adjusted cumulative sum (CUSUM). From 1988 to 2014, 119 simultaneous pancreas and the kidney transplantations (SPKTx) were performed. The program was divided into 3 eras, based on surgical technique and immunosuppression. Analyses of the 15 fatal outcomes due to complication from pancreatic graft were performed. The risk model was developed using multivariable logistic regression analysis based on retrospective data of 112 SPKTx recipients. The risk-adjusted 1-sided CUSUM chart was plotted for retrospective and prospective events. The upper control limit was set to 2. There were 2 main causes of death: multiorgan failure (73.3%; 11/15) and septic hemorrhage (26.7%; 4/15). Quality analysis using the CUSUM chart revealed that the process was not homogeneous; however, no significant signal of program deterioration was obtained and the performance of the whole program was within the settled control limit. For a single pancreatic transplant center. The risk-adjusted CUSUM chart was a useful tool for quality program assessment. It could support decision making during traditional surgical morbidity and mortality conferences. For small transplant centers, increasing the sensitivity of the CUSUM method by lowering the upper control limit should be considered. However, an individual assessment approach of the for particular centers is recommended.

  12. Monitoring surface-water quality in Arizona: the fixed-station network

    USGS Publications Warehouse

    Tadayon, Saeid

    2000-01-01

    Arizona is an arid State in which economic development is influenced largely by the quantity and quality of water and the location of adequate water supplies. In 1995, surface water supplied about 58 percent of total withdrawals in Arizona. Of the total amount of surface water used in 1995, about 89 percent was for agriculture, 10 percent for public supply, and 1 percent for industrial supply (including mining and thermoelectric; Solley and others, 1998). As a result of rapid population growth in Arizona, historic agricultural lands in the Phoenix (Maricopa County) and Tucson (Pima County) areas are now being developed for residential and commercial use; thus, the amount of water used for public supply is increasing. The Clean Water Act was established by U.S. Congress (1972) in response to public concern about water-pollution control. The act defines a process by which the United States Congress and the citizens are informed of the Nation’s progress in restoring and maintaining the quality of our waters. The Arizona Department of Environmental Quality (ADEQ) is the State-designated agency for this process and, as a result, has developed a monitoring program to assess water quality in Arizona. The ADEQ is required to submit a water-quality assessment report to the United States Environmental Protection Agency (USEPA) every 2 years. The USEPA summarizes the reports from each State and submits a report to the Congress characterizing water quality in the United States. These reports serve to inform Congress and the public of the Nation’s progress toward the restoration and maintenance of water quality in the United States (Arizona Department of Environmental Quality, 1998).

  13. Laboratory Innovation Towards Quality Program Sustainability.

    PubMed

    Abimiku, Alash'le; Timperi, Ralph; Blattner, William

    2016-08-01

    Laboratory innovation significantly affects program sustainability of HIV programs in low and middle income countries (LMICs) far beyond its immediate sphere of impact. Innovation in rapid development of diagnostic technologies, improved quality management systems, strengthened laboratory management, affordable external quality assurance and accreditation schemes, and building local capacity have reduced costs, brought quality improvement to point-of-care testing, increased access to testing services, reduced treatment and prevention costs and opened the door to the real possibility of ending the AIDS epidemic. However, for effectively implemented laboratory innovation to contribute to HIV quality program sustainability, it must be implemented within the overall context of the national strategic plan and HIV treatment programs. The high quality of HIV rapid diagnostic test was a breakthrough that made it possible for more persons to learn their HIV status, receive counseling, and if infected to receive treatment. Likewise, the use of dried blood spots made the shipment of samples easier for the assessment of different variables of HIV infection-molecular diagnosis, CD4+ cell counts, HIV antibodies, drug resistance surveillance, and even antiretroviral drug level measurements. Such advancement is critical for to reaching the UNAIDS target of 90-90-90 and for bringing the AIDS epidemic to an end, especially in LMICs.

  14. Real-time water quality monitoring and providing water quality information to the Baltimore Community

    EPA Science Inventory

    EPA and the U.S. Geological Survey (USGS) have initiated the “Village Blue” research project to provide real-time water quality monitoring data to the Baltimore community and increase public awareness about local water quality in Baltimore Harbor and the Chesapeake Ba...

  15. Letter Report Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Tonopah Airport, Nye County, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. Engelbrecht; I. Kavouras; D. Campbell

    2009-04-02

    The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Tonopah Airport, Beatty, Rachel, Caliente, Pahranagat NWR, Crater Flat, and the Tonopah Airport, and at four sites on the NTS (Engelbrecht et al.,more » 2007a-d). The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data, on completion of the site's sampling program.« less

  16. Letter Report: Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Tonopah Airport, Nye County, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. Engelbrecht; I. Kavouras; D Campbell

    2008-08-01

    The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Tonopah Airport, Beatty, Rachel, Caliente, Pahranagat NWR, Crater Flat, and the Tonopah Airport, and at four sites on the NTS (Engelbrecht et al.,more » 2007a-d). The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data, on completion of the site's sampling program.« less

  17. Rationale for Quality Assurance in Fecal Egg Monitoring of Soil-Transmitted Helminthiasis.

    PubMed

    Hoekendijk, David J L; Hill, Philip C; Sowerby, Stephen J

    2016-09-07

    Substantial investment has been made into the once "neglected" tropical disease, soil-transmitted helminthiasis, and into control programs that operate within a framework of mapping baseline disease distribution, measuring the effectiveness of applied interventions, establishing when to cease drug administration, and for posttreatment evaluations. However, critical to each of these stages is the determination of helminth infection. The limitations of traditional microscope-based fecal egg diagnostics have not provided quality assurance in the monitoring of parasite disease and suboptimal treatment regimes provide for the potential development of parasite resistance to anthelmintic drugs. Improved diagnostic and surveillance tools are required to protect therapeutic effectiveness and to maintain funder confidence. Such tools may be on the horizon with emergent technologies that offer potential for enhanced visualization and quality-assured quantitation of helminth eggs. © The American Society of Tropical Medicine and Hygiene.

  18. Monitoring and modeling of microbial and biological water quality

    USDA-ARS?s Scientific Manuscript database

    Microbial and biological water quality informs on the health of water systems and their suitability for uses in irrigation, recreation, aquaculture, and other activities. Indicators of microbial and biological water quality demonstrate high spatial and temporal variability. Therefore, monitoring str...

  19. LOVE CANAL MONITORING PROGRAM. VOLUME 1

    EPA Science Inventory

    This report summarizes the prime contractor activities during the monitoring phase of the Love Canal project. Since GCA Corporation was only responsible for data collection, no analytical results appear in this report. The program involved a multifaceted sampling and analytical e...

  20. In-situ quality monitoring during laser brazing

    NASA Astrophysics Data System (ADS)

    Ungers, Michael; Fecker, Daniel; Frank, Sascha; Donst, Dmitri; Märgner, Volker; Abels, Peter; Kaierle, Stefan

    Laser brazing of zinc coated steel is a widely established manufacturing process in the automotive sector, where high quality requirements must be fulfilled. The strength, impermeablitiy and surface appearance of the joint are particularly important for judging its quality. The development of an on-line quality control system is highly desired by the industry. This paper presents recent works on the development of such a system, which consists of two cameras operating in different spectral ranges. For the evaluation of the system, seam imperfections are created artificially during experiments. Finally image processing algorithms for monitoring process parameters based the captured images are presented.

  1. Overview of the forest health monitoring program

    Treesearch

    2000-01-01

    This paper presents an overview of the Forest Health Monitoring Program (FHM), a partnership among the USDA Forest Service, State Foresters, universities, and the USDI Bureau of Land Management. The purpose of FHM is to annually assess the condition of the nation's forested ecosystems in a standardized way. There are four components of the program - Detection...

  2. Overview of the Forest Health Monitoring Program

    Treesearch

    2000-01-01

    This paper presents an overview of the Forest Health Monitoring Program (FHM), a partnership among the USDA Forest Service, State Foresters, universities, and the USDI Bureau of Land Management. The purpose of FHM is to annually assess the condition of the Nation's forested ecosystems in a standardized way. There are four components of the program-Detection...

  3. Monitoring water quality by remote sensing

    NASA Technical Reports Server (NTRS)

    Brown, R. L. (Principal Investigator)

    1977-01-01

    The author has identified the following significant results. A limited study was conducted to determine the applicability of remote sensing for evaluating water quality conditions in the San Francisco Bay and delta. Considerable supporting data were available for the study area from other than overflight sources, but short-term temporal and spatial variability precluded their use. The study results were not sufficient to shed much light on the subject, but it did appear that, with the present state of the art in image analysis and the large amount of ground truth needed, remote sensing has only limited application in monitoring water quality.

  4. OPTICAL REMOTE SENSING FOR AIR QUALITY MONITORING

    EPA Science Inventory

    The paper outlines recent developments in using optical remote sensing (ORS) instruments for air quality monitoring both for gaseous pollutants and airborne particulate matter (PM). The U.S. Environmental Protection Agency (EPA) has been using open-path Fourier transform infrared...

  5. Apollo Quality Program.

    PubMed

    Sibal, Anupam; Dewan, Shaveta; Uberoi, R S; Kar, Sujoy; Loria, Gaurav; Fernandes, Clive; Yatheesh, G; Sharma, Karan

    2012-01-01

    Ensuring patient safety is a vital step for any hospital in achieving the best clinical outcomes. The Apollo Quality Program aimed at standardization of processes for clinical handovers, medication safety, surgical safety, patient identification, verbal orders, hand washing compliance and falls prevention across the hospitals in the Group. Thirty-two hospitals across the Group in settings varying from rural to semi urban, urban and metropolitan implemented the program and over a period of one year demonstrated a visible improvement in the compliance to processes for patient safety translating into better patient safety statistics.

  6. DESIGNING A COMPREHENSIVE, INTEGRATED WATER RESOURCES MONITORING PROGRAM FOR FLORIDA

    EPA Science Inventory

    Proceedings of the National Water Quality Monitoring Conference "Monitoring Critical Foundations to Protect Our Waters," 7-9 July 1998, Reno, NV.

    In late 1996, Florida Department of Environmental Protection (FDEP) initiated an effort to design a multi-tiered monitoring and...

  7. Environmental stratification framework and water-quality monitoring design strategy for the Islamic Republic of Mauritania, Africa

    USGS Publications Warehouse

    Friedel, Michael J.

    2008-01-01

    Mauritania anticipates an increase in mining activities throughout the country and into the foreseeable future. Because mining-induced changes in the landscape are likely to affect their limited ground-water resources and sensitive aquatic ecosystems, a water-quality assessment program was designed for Mauritania that is based on a nationally consistent environmental stratification framework. The primary objectives of this program are to ensure that the environmental monitoring systems can quantify near real-time changes in surface-water chemistry at a local scale, and quantify intermediate- to long-term changes in groundwater and aquatic ecosystems over multiple scales.

  8. 78 FR 7816 - Quality Assurance Program Requirements (Operations)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-04

    ... NUCLEAR REGULATORY COMMISSION [NRC-2013-0021] Quality Assurance Program Requirements (Operations...), DG-1300, ``Quality Assurance Program Requirements (Operations).'' DATES: Submit comments by April 1... CFR Part 50, Appendix B, ``Quality Assurance Criteria for Nuclear power Plants and Fuel Reprocessing...

  9. Total Quality Management Simplified.

    ERIC Educational Resources Information Center

    Arias, Pam

    1995-01-01

    Maintains that Total Quality Management (TQM) is one method that helps to monitor and improve the quality of child care. Lists four steps for a child-care center to design and implement its own TQM program. Suggests that quality assurance in child-care settings is an ongoing process, and that TQM programs help in providing consistent, high-quality…

  10. Computer program CDCID: an automated quality control program using CDC update

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singer, G.L.; Aguilar, F.

    1984-04-01

    A computer program, CDCID, has been developed in coordination with a quality control program to provide a highly automated method of documenting changes to computer codes at EG and G Idaho, Inc. The method uses the standard CDC UPDATE program in such a manner that updates and their associated documentation are easily made and retrieved in various formats. The method allows each card image of a source program to point to the document which describes it, who created the card, and when it was created. The method described is applicable to the quality control of computer programs in general. Themore » computer program described is executable only on CDC computing systems, but the program could be modified and applied to any computing system with an adequate updating program.« less

  11. Elk-effects vegetation monitoring program for Tomales Point Elk Range, Point Reyes National Seashore, California

    USGS Publications Warehouse

    McEachern, Kathryn; Semenoff-Irving, Marcia; van der Leeden, Pamela

    2000-01-01

    The monitoring program for elk effects on Tomales Point vegetation is designed to provide information on how tule elk grazing affects plant communities and rare species. The basic objective of the program is to show whether the elk are driving the vegetation into an unacceptable state by their grazing. The expectation is that as elk numbers increase, grazing pressure will increase too, resulting in unacceptable levels of any or all of the following: low vegetation ground cover, poor nutritional quality for the elk, undesirable increases in weedy species, unacceptable loss of native plant biodiversity, population declines in rare plants, population declines in plants used for food and nectar by the endangered silverspot butterfly, and increased erosion.The monitoring program has 3 basic components designed to provide complementary information on different aspects of the elk-vegetation system. Long-term plant community monitoring along permanent transects will show how plant species composition and cover are changing since cattle removal in 1979, and it will show whether any of he undesirable traits listed above are developing in the vegetation. However, monitoring these transects alone will not tell us what the effects of continued grazing by elk are apart from changes the vegetation would be undergoing anyway. In order to tease apart the elk effects from change that is happening because of cattle removal, elk exclosures are needed. By sampling inside and outside exclosures, we will be able to see how elk are modifying the rates and directions of change in the vegetation that would be happening in their absence. In a sense, the exclosures serve as a “check” on elk effects. They will allow us to interpret how much of the change is due to elk and how much can be attributed to other processes such as natural succession or weather patterns. This information will allow us to analyze whether changing elk management will have a desirable effect on the vegetation

  12. 78 FR 37850 - Quality Assurance Program Requirements (Operations)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-24

    ... NUCLEAR REGULATORY COMMISSION [NRC-2013-0021] Quality Assurance Program Requirements (Operations... Regulatory Commission (NRC) is issuing a revision to Regulatory Guide (RG) 1.33, ``Quality Assurance Program... managerial and administrative Quality Assurance (QA) controls for nuclear power plants during operations...

  13. 25 CFR 276.9 - Monitoring and reporting program performances.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... EDUCATION ASSISTANCE ACT PROGRAM UNIFORM ADMINISTRATIVE REQUIREMENTS FOR GRANTS § 276.9 Monitoring and... the following for each program, function, or activity involved: (1) A comparison of actual...

  14. 25 CFR 276.9 - Monitoring and reporting program performances.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... EDUCATION ASSISTANCE ACT PROGRAM UNIFORM ADMINISTRATIVE REQUIREMENTS FOR GRANTS § 276.9 Monitoring and... the following for each program, function, or activity involved: (1) A comparison of actual...

  15. 25 CFR 276.9 - Monitoring and reporting program performances.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... EDUCATION ASSISTANCE ACT PROGRAM UNIFORM ADMINISTRATIVE REQUIREMENTS FOR GRANTS § 276.9 Monitoring and... the following for each program, function, or activity involved: (1) A comparison of actual...

  16. Toward development of a comprehensive external quality assurance program for polyfunctional intracellular cytokine staining assays

    PubMed Central

    Staats, Janet S.; Enzor, Jennifer H.; Sanchez, Ana M.; Rountree, Wes; Chan, Cliburn; Jaimes, Maria; Chan, Ray Chun-Fai; Gaur, Amitabh; Denny, Thomas N.; Weinhold, Kent J.

    2014-01-01

    The External Quality Assurance Program Oversight Laboratory (EQAPOL) Flow Cytometry Program assesses the proficiency of NIH/NIAID/DAIDS-supported and potentially other interested research laboratories in performing Intracellular Cytokine Staining (ICS) assays. The goal of the EQAPOL Flow Cytometry External Quality Assurance Program (EQAP) is to provide proficiency testing and remediation for participating sites. The program is not punitive; rather, EQAPOL aims to help sites identify areas for improvement. EQAPOL utilizes a highly standardized ICS assay to minimize variability and readily identify those sites experiencing technical difficulties with their assays. Here, we report the results of External Proficiency 3 (EP3) where participating sites performed a 7-color ICS assay. On average, sites perform well in the Flow Cytometry EQAP (median score is “Good”). The most common technical issues identified by the program involve protocol adherence and data analysis; these areas have been the focus of site remediation. The EQAPOL Flow Cytometry team is now in the process of expanding the program to 8-color ICS assays. Evaluating polyfunctional ICS responses would align the program with assays currently being performed in support of HIV immune monitoring assays. PMID:24968072

  17. Minnesota 4-H Youth Program Quality Improvement Model

    ERIC Educational Resources Information Center

    Herman, Margo; Grant, Samantha

    2015-01-01

    The University of Minnesota Extension Center for Youth Development made an organizational decision in 2011 to invest in a system-wide approach to implement youth program quality into the 4-H program using the Youth Program Quality Assessment (YPQA) tool. This article describes the four key components to the Minnesota Youth Program Quality…

  18. Space Station Environmental Health System water quality monitoring

    NASA Technical Reports Server (NTRS)

    Vincze, Johanna E.; Sauer, Richard L.

    1990-01-01

    One of the unique aspects of the Space Station is that it will be a totally encapsulated environment and the air and water supplies will be reclaimed for reuse. The Environmental Health System, a subsystem of CHeCS (Crew Health Care System), must monitor the air and water on board the Space Station Freedom to verify that the quality is adequate for crew safety. Specifically, the Water Quality Subsystem will analyze the potable and hygiene water supplies regularly for organic, inorganic, particulate, and microbial contamination. The equipment selected to perform these analyses will be commercially available instruments which will be converted for use on board the Space Station Freedom. Therefore, the commercial hardware will be analyzed to identify the gravity dependent functions and modified to eliminate them. The selection, analysis, and conversion of the off-the-shelf equipment for monitoring the Space Station reclaimed water creates a challenging project for the Water Quality engineers and scientists.

  19. History and results of the Northern Forest Health Monitoring Program

    Treesearch

    Charles J. Barnett

    2000-01-01

    Forest Health Monitoring (FHM) Program was established because of a concern that the forests in the United States were declining. The program was established to monitor the state of and changes in forest conditions across the nation. This report looks at the distributions of trees into various rating categories for three variables collected on the FHM plots from 1991...

  20. Quality Program Provisions for Aeronautical and Space System Contractors

    NASA Technical Reports Server (NTRS)

    1969-01-01

    This publication sets forth quality program requirements for NASA aeronautical and space programs, systems, subsystems, and related services. These requirements provide for the effective operation of a quality program which ensures that quality criteria and requirements are recognized, definitized, and performed satisfactorily.

  1. Remote sensing inputs to National Model Implementation Program for water resources quality improvement

    NASA Technical Reports Server (NTRS)

    Eidenshink, J. C.; Schmer, F. A.

    1979-01-01

    The Lake Herman watershed in southeastern South Dakota has been selected as one of seven water resources systems in the United States for involvement in the National Model Implementation Program (MIP). MIP is a pilot program initiated to illustrate the effectiveness of existing water resources quality improvement programs. The Remote Sensing Institute (RSI) at South Dakota State University has produced a computerized geographic information system for the Lake Herman watershed. All components necessary for the monitoring and evaluation process were included in the data base. The computerized data were used to produce thematic maps and tabular data for the land cover and soil classes within the watershed. These data are being utilized operationally by SCS resource personnel for planning and management purposes.

  2. Water Quality Analysis Simulation Program (WASP)

    EPA Pesticide Factsheets

    The Water Quality Analysis Simulation Program (WASP) model helps users interpret and predict water quality responses to natural phenomena and manmade pollution for various pollution management decisions.

  3. Changes in water quality along the course of a river - Classic monitoring versus patrol monitoring

    NASA Astrophysics Data System (ADS)

    Absalon, Damian; Kryszczuk, Paweł; Rutkiewicz, Paweł

    2017-11-01

    Monitoring of water quality is a tool necessary to assess the condition of waterbodies in order to properly formulate water management plans. The paper presents the results of patrol monitoring of a 40-kilometre stretch of the Oder between Racibórz and Koźle. It has been established that patrol monitoring is a good tool for verifying the distribution of points of classic stationary monitoring, particularly in areas subject to varied human impact, where tributaries of the main river are very diversified as regards hydrochemistry. For this reason the results of operational monitoring carried out once every few years may not be reliable and the presented condition of the monitored waterbodies may be far from reality.

  4. Water Quality Sensing and Spatio-Temporal Monitoring Structure with Autocorrelation Kernel Methods

    PubMed Central

    Vizcaíno, Iván P.; Muñoz-Romero, Sergio; Cumbal, Luis H.

    2017-01-01

    Pollution on water resources is usually analyzed with monitoring campaigns, which consist of programmed sampling, measurement, and recording of the most representative water quality parameters. These campaign measurements yields a non-uniform spatio-temporal sampled data structure to characterize complex dynamics phenomena. In this work, we propose an enhanced statistical interpolation method to provide water quality managers with statistically interpolated representations of spatial-temporal dynamics. Specifically, our proposal makes efficient use of the a priori available information of the quality parameter measurements through Support Vector Regression (SVR) based on Mercer’s kernels. The methods are benchmarked against previously proposed methods in three segments of the Machángara River and one segment of the San Pedro River in Ecuador, and their different dynamics are shown by statistically interpolated spatial-temporal maps. The best interpolation performance in terms of mean absolute error was the SVR with Mercer’s kernel given by either the Mahalanobis spatial-temporal covariance matrix or by the bivariate estimated autocorrelation function. In particular, the autocorrelation kernel provides with significant improvement of the estimation quality, consistently for all the six water quality variables, which points out the relevance of including a priori knowledge of the problem. PMID:29035333

  5. Monitoring and Assuring the Quality of Digital Aerial Data

    NASA Technical Reports Server (NTRS)

    Christopherson, Jon

    2007-01-01

    This viewgraph presentation explains the USGS plan for monitoring and assuring the quality of digital aerial data. The contents include: 1) History of USGS Aerial Imaging Involvement; 2) USGS Research and Results; 3) Outline of USGS Quality Assurance Plan; 4) Other areas of Interest; and 5) Summary

  6. Key Performance Indicators in the Evaluation of the Quality of Radiation Safety Programs.

    PubMed

    Schultz, Cheryl Culver; Shaffer, Sheila; Fink-Bennett, Darlene; Winokur, Kay

    2016-08-01

    Beaumont is a multiple hospital health care system with a centralized radiation safety department. The health system operates under a broad scope Nuclear Regulatory Commission license but also maintains several other limited use NRC licenses in off-site facilities and clinics. The hospital-based program is expansive including diagnostic radiology and nuclear medicine (molecular imaging), interventional radiology, a comprehensive cardiovascular program, multiple forms of radiation therapy (low dose rate brachytherapy, high dose rate brachytherapy, external beam radiotherapy, and gamma knife), and the Research Institute (including basic bench top, human and animal). Each year, in the annual report, data is analyzed and then tracked and trended. While any summary report will, by nature, include items such as the number of pieces of equipment, inspections performed, staff monitored and educated and other similar parameters, not all include an objective review of the quality and effectiveness of the program. Through objective numerical data Beaumont adopted seven key performance indicators. The assertion made is that key performance indicators can be used to establish benchmarks for evaluation and comparison of the effectiveness and quality of radiation safety programs. Based on over a decade of data collection, and adoption of key performance indicators, this paper demonstrates one way to establish objective benchmarking for radiation safety programs in the health care environment.

  7. A quality monitoring program for red blood cell components: in vitro quality indicators before and after implementation of semiautomated processing.

    PubMed

    Acker, Jason P; Hansen, Adele L; Kurach, Jayme D R; Turner, Tracey R; Croteau, Ioana; Jenkins, Craig

    2014-10-01

    Canadian Blood Services has been conducting quality monitoring of red blood cell (RBC) components since 2005, a period spanning the implementation of semiautomated component production. The aim was to compare the quality of RBC components produced before and after this production method change. Data from 572 RBC units were analyzed, categorized by production method: Method 1, RBC units produced by manual production methods; Method 2, RBC units produced by semiautomated production and the buffy coat method; and Method 3, RBC units produced by semiautomated production and the whole blood filtration method. RBC units were assessed using an extensive panel of in vitro tests, encompassing regulated quality control criteria such as hematocrit (Hct), hemolysis, and hemoglobin (Hb) levels, as well as adenosine triphosphate, 2,3-diphosphoglycerate, extracellular K(+) and Na(+) levels, methemoglobin, p50, RBC indices, and morphology. Throughout the study, all RBC units met mandated Canadian Standards Association guidelines for Hb and Hct, and most (>99%) met hemolysis requirements. However, there were significant differences among RBC units produced using different methods. Hb content was significantly lower in RBC units produced by Method 2 (51.5 ± 5.6 g/unit; p < 0.001). At expiry, hemolysis was lowest in Method 2-produced RBC units (p < 0.05) and extracellular K(+) levels were lowest in units produced by Method 1 (p < 0.001). While overall quality was similar before and after the production method change, the observed differences, although small, indicate a lack of equivalency across RBC products manufactured by different methods. © 2014 AABB.

  8. Telemedicine spirometry training and quality assurance program in primary care centers of a public health system.

    PubMed

    Marina Malanda, Nuria; López de Santa María, Elena; Gutiérrez, Asunción; Bayón, Juan Carlos; Garcia, Larraitz; Gáldiz, Juan B

    2014-04-01

    Forced spirometry is essential for diagnosing respiratory diseases and is widely used across levels of care. However, several studies have shown that spirometry quality in primary care is not ideal, with risks of misdiagnosis. Our objective was to assess the feasibility and performance of a telemedicine-based training and quality assurance program for forced spirometry in primary care. The two phases included (1) a 9-month pilot study involving 15 centers, in which spirometry tests were assessed by the Basque Office for Health Technology Assessment, and (2) the introduction of the program to all centers in the Public Basque Health Service. Technicians first received 4 h of training, and, subsequently, they sent all tests to the reference laboratory using the program. Quality assessment was performed in accordance with clinical guidelines (A and B, good; C-F, poor). In the first phase, 1,894 spirometry tests were assessed, showing an improvement in quality: acceptable quality tests increased from 57% at the beginning to 78% after 6 months and 83% after 9 months (p<0.001). In the second phase, 7,200 spirometry tests were assessed after the inclusion of 36 additional centers, maintaining the positive trend (61%, 87%, and 84% at the same time points; p<0.001). (1) The quality of spirometry tests improved in all centers. (2) The program provides a tool for transferring data that allows monitoring of its quality and training of technicians who perform the tests. (3) This approach is useful for improving spirometry quality in the routine practice of a public health system.

  9. Developing policy, standard orders, and quality-assurance monitoring for palliative sedation therapy.

    PubMed

    Ghafoor, Virginia L; Silus, Lauren S

    2011-03-15

    The development of a policy, evidence-based standard orders, and monitoring for palliative sedation therapy (PST) is described. Concerns regarding PST at the University of Minnesota Medical Center (UMMC) arose and needed to be addressed in a formal process. A multidisciplinary group consisting of palliative care physicians, nurse practitioners, clinical nurse specialists, and clinical pharmacy specialists reached consensus on the practice model and medications to be used for PST. Major elements of the plan included the development and implementation of an institutional policy for palliative sedation; standard orders for patient care, sedation, and monitoring; education for staff, patients, and patients' family members; and quality-assurance monitoring. A literature review was performed to identify research and guidelines defining the practice of PST. Policy content includes the use of a standard order set linking patient care, medication administration, the monitoring of sedation, and symptom management. Approval of the policy involved several UMMC committees. An evaluation matrix was used to determine critical areas for PST monitoring and to guide development of a form to monitor quality. A retrospective chart audit using the quality-assurance monitoring form assessed baseline sedation medication and patient outcomes. Assessment of compliance began in the fall of 2008, after the policy and standard orders were approved by the UMMC medical executive committee. In 2008, two cases of PST were monitored using the standardized form. PST cases will be continually monitored and analyzed. Development of policy, standard orders, and quality-assurance monitoring for PST required a formal multidisciplinary process. A process-improvement process is critical to defining institutional policy, educational goals, and outcome metrics for PST.

  10. Internal quality control indicators of cervical cytopathology exams performed in laboratories monitored by the External Quality Control Laboratory.

    PubMed

    Ázara, Cinara Zago Silveira; Manrique, Edna Joana Cláudio; Tavares, Suelene Brito do Nascimento; de Souza, Nadja Lindany Alves; Amaral, Rita Goreti

    2014-09-01

    To evaluate the impact of continued education provided by an external quality control laboratory on the indicators of internal quality control of cytopathology exams. The internal quality assurance indicators for cytopathology exams from 12 laboratories monitored by the External Quality Control Laboratory were evaluated. Overall, 185,194 exams were included, 98,133 of which referred to the period preceding implementation of a continued education program, while 87,061 referred to the period following this intervention. Data were obtained from the Cervical Cancer Database of the Brazilian National Health Service. Following implementation of the continued education program, the positivity index (PI) remained within recommended limits in four laboratories. In another four laboratories, the PI progressed from below the limits to within the recommended standards. In one laboratory, the PI remained low, in two laboratories, it remained very low, and in one, it increased from very low to low. The percentage of exams compatible with a high-grade squamous intraepithelial lesion (HSIL) remained within the recommended limits in five laboratories, while in three laboratories it progressed from below the recommended levels to >0.4% of the total number of satisfactory exams, and in four laboratories it remained below the standard limit. Both the percentage of atypical squamous cells of undetermined significance (ASC-US) in relation to abnormal exams, and the ratio between ASC-US and intraepithelial lesions remained within recommended levels in all the laboratories investigated. An improvement was found in the indicators represented by the positivity index and the percentage of exams compatible with a high-grade squamous intraepithelial lesion, showing that the role played by the external quality control laboratory in providing continued education contributed towards improving laboratory staff skills in detecting cervical cancer precursor lesions.

  11. 77 FR 71609 - Self-Help Homeownership Opportunity Program (SHOP) Grant Monitoring

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-03

    ... DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT [Docket No. FR-5603-N-89] Self-Help Homeownership Opportunity Program (SHOP) Grant Monitoring AGENCY: Office of the Chief Information Officer, HUD. ACTION...-Help Homeownership Opportunity Program (SHOP) Grant Monitoring. OMB Approval Number: 2506-0157. Form...

  12. Recent Advances in Point-of-Access Water Quality Monitoring

    NASA Astrophysics Data System (ADS)

    Korostynska, O.; Arshak, K.; Velusamy, V.; Arshak, A.; Vaseashta, Ashok

    Clean water is one of our most valuable natural resources. In addition to providing safe drinking water it assures functional ecosystems that support fisheries and recreation. Human population growth and its associated increased demands on water pose risks to maintaining acceptable water quality. It is vital to assess source waters and the aquatic systems that receive inputs from industrial waste and sewage treatment plants, storm water systems, and runoff from urban and agricultural lands. Rapid and confident assessments of aquatic resources form the basis for sound environmental management. Current methods engaged in tracing the presence of various bacteria in water employ bulky laboratory equipment and are time consuming. Thus, real-time water quality monitoring is essential for National and International Health and Safety. Environmental water monitoring includes measurements of physical characteristics (e.g. pH, temperature, conductivity), chemical parameters (e.g. oxygen, alkalinity, nitrogen and phosphorus compounds), and abundance of certain biological taxa. Monitoring could also include assays of biological activity such as alkaline phosphatase, tests for toxins such as microcystins and direct measurements of pollutants such as heavy metals or hydrocarbons. Real time detection can significantly reduce the level of damage and also the cost to remedy the problem. This paper presents overview of state-of-the-art methods and devices used for point-of-access water quality monitoring and suggest further developments in this area.

  13. NATIONAL WATER-QUALITY ASSESSMENT (NAWQA) PROGRAM

    EPA Science Inventory

    The National Water-Quality Assessment (NAWQA) Program is designed to describe the status and trends in the quality of the Nations ground- and surface-water resources and to provide a sound understanding of the natural and human factors that affect the quality of these resources. ...

  14. The Savannah River Site's Groundwater Monitoring Program, third quarter 1991

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The Environmental Protection Department/Environmental Monitoring Section (EPD/EMS) administers the Savannah River Site's (SRS) Groundwater Monitoring Program. During third quarter 1991, EPD/EMS conducted extensive sampling of monitoring wells. Analytical results from third quarter 1991 are listed in this report.

  15. 10 CFR 63.144 - Quality assurance program change.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 2 2011-01-01 2011-01-01 false Quality assurance program change. 63.144 Section 63.144 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) DISPOSAL OF HIGH-LEVEL RADIOACTIVE WASTES IN A GEOLOGIC... assurance program information that duplicates language in quality assurance regulatory guides and quality...

  16. 10 CFR 600.341 - Monitoring and reporting program and financial performance.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Monitoring and reporting program and financial performance. 600.341 Section 600.341 Energy DEPARTMENT OF ENERGY (CONTINUED) ASSISTANCE REGULATIONS FINANCIAL... Organizations Post-Award Requirements § 600.341 Monitoring and reporting program and financial performance. (a...

  17. Letter Report: Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Pahranagat National Wildlife Refuge, Lincoln County, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. Englebrecht; I. Kavouras; D. Campbell

    2008-08-01

    The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Pahranagat NWR, Beatty, Rachel, Caliente, Crater Flat, and Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d). The trailermore » is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data on completion of the site's sampling program.« less

  18. Letter Report Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Pahranagat National Wildlife Refuge, Lincoln County, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. Engelbrecht; I. Kavouras; D. Campbell

    2009-04-02

    The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Pahranagat NWR, Beatty, Rachel, Caliente, Crater Flat, and Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d). The trailermore » is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data on completion of the site's sampling program.« less

  19. A Survey on Data Quality for Dependable Monitoring in Wireless Sensor Networks

    PubMed Central

    Oliveira, Anabela

    2017-01-01

    Wireless sensor networks are being increasingly used in several application areas, particularly to collect data and monitor physical processes. Non-functional requirements, like reliability, security or availability, are often important and must be accounted for in the application development. For that purpose, there is a large body of knowledge on dependability techniques for distributed systems, which provide a good basis to understand how to satisfy these non-functional requirements of WSN-based monitoring applications. Given the data-centric nature of monitoring applications, it is of particular importance to ensure that data are reliable or, more generically, that they have the necessary quality. In this survey, we look into the problem of ensuring the desired quality of data for dependable monitoring using WSNs. We take a dependability-oriented perspective, reviewing the possible impairments to dependability and the prominent existing solutions to solve or mitigate these impairments. Despite the variety of components that may form a WSN-based monitoring system, we give particular attention to understanding which faults can affect sensors, how they can affect the quality of the information and how this quality can be improved and quantified. PMID:28869505

  20. A Survey on Data Quality for Dependable Monitoring in Wireless Sensor Networks.

    PubMed

    Jesus, Gonçalo; Casimiro, António; Oliveira, Anabela

    2017-09-02

    Wireless sensor networks are being increasingly used in several application areas, particularly to collect data and monitor physical processes. Non-functional requirements, like reliability, security or availability, are often important and must be accounted for in the application development. For that purpose, there is a large body of knowledge on dependability techniques for distributed systems, which provide a good basis to understand how to satisfy these non-functional requirements of WSN-based monitoring applications. Given the data-centric nature of monitoring applications, it is of particular importance to ensure that data are reliable or, more generically, that they have the necessary quality. In this survey, we look into the problem of ensuring the desired quality of data for dependable monitoring using WSNs. We take a dependability-oriented perspective, reviewing the possible impairments to dependability and the prominent existing solutions to solve or mitigate these impairments. Despite the variety of components that may form a WSN-based monitoring system, we give particular attention to understanding which faults can affect sensors, how they can affect the quality of the information and how this quality can be improved and quantified.

  1. Development of GUI Type On-Line Condition Monitoring Program for a Turboprop Engine Using Labview

    NASA Astrophysics Data System (ADS)

    Kong, Changduk; Kim, Keonwoo

    2011-12-01

    Recently, an aero gas turbine health monitoring system has been developed for precaution and maintenance action against faults or performance degradations of the advanced propulsion system which occurs in severe environments such as high altitude, foreign object damage particles, hot and heavy rain and snowy atmospheric conditions. However to establish this health monitoring system, the online condition monitoring program is firstly required, and the program must monitor the engine performance trend through comparison between measured engine performance data and base performance results calculated by base engine performance model. This work aims to develop a GUI type on-line condition monitoring program for the PT6A-67 turboprop engine of a high altitude and long endurance operation UAV using LabVIEW. The base engine performance of the on-line condition monitoring program is simulated using component maps inversely generated from the limited performance deck data provided by engine manufacturer. The base engine performance simulation program is evaluated because analysis results by this program agree well with the performance deck data. The proposed on-line condition program can monitor the real engine performance as well as the trend through precise comparison between clean engine performance results calculated by the base performance simulation program and measured engine performance signals. In the development phase of this monitoring system, a signal generation module is proposed to evaluate the proposed online monitoring system. For user friendly purpose, all monitoring program are coded by LabVIEW, and monitoring examples are demonstrated using the proposed GUI type on-condition monitoring program.

  2. 48 CFR 2146.270 - FEGLI Program quality assurance requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... MANAGEMENT, FEDERAL EMPLOYEES GROUP LIFE INSURANCE FEDERAL ACQUISITION REGULATION CONTRACT MANAGEMENT QUALITY ASSURANCE Contract Quality Requirements 2146.270 FEGLI Program quality assurance requirements. (a) The... 48 Federal Acquisition Regulations System 6 2013-10-01 2013-10-01 false FEGLI Program quality...

  3. 48 CFR 2146.270 - FEGLI Program quality assurance requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... MANAGEMENT, FEDERAL EMPLOYEES GROUP LIFE INSURANCE FEDERAL ACQUISITION REGULATION CONTRACT MANAGEMENT QUALITY ASSURANCE Contract Quality Requirements 2146.270 FEGLI Program quality assurance requirements. (a) The... 48 Federal Acquisition Regulations System 6 2014-10-01 2014-10-01 false FEGLI Program quality...

  4. 48 CFR 2146.270 - FEGLI Program quality assurance requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... MANAGEMENT, FEDERAL EMPLOYEES GROUP LIFE INSURANCE FEDERAL ACQUISITION REGULATION CONTRACT MANAGEMENT QUALITY ASSURANCE Contract Quality Requirements 2146.270 FEGLI Program quality assurance requirements. (a) The... 48 Federal Acquisition Regulations System 6 2012-10-01 2012-10-01 false FEGLI Program quality...

  5. 48 CFR 2146.270 - FEGLI Program quality assurance requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... MANAGEMENT, FEDERAL EMPLOYEES GROUP LIFE INSURANCE FEDERAL ACQUISITION REGULATION CONTRACT MANAGEMENT QUALITY ASSURANCE Contract Quality Requirements 2146.270 FEGLI Program quality assurance requirements. (a) The... 48 Federal Acquisition Regulations System 6 2011-10-01 2011-10-01 false FEGLI Program quality...

  6. 48 CFR 2146.270 - FEGLI Program quality assurance requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... MANAGEMENT, FEDERAL EMPLOYEES GROUP LIFE INSURANCE FEDERAL ACQUISITION REGULATION CONTRACT MANAGEMENT QUALITY ASSURANCE Contract Quality Requirements 2146.270 FEGLI Program quality assurance requirements. (a) The... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true FEGLI Program quality...

  7. The swiss neonatal quality cycle, a monitor for clinical performance and tool for quality improvement

    PubMed Central

    2013-01-01

    Background We describe the setup of a neonatal quality improvement tool and list which peer-reviewed requirements it fulfils and which it does not. We report on the so-far observed effects, how the units can identify quality improvement potential, and how they can measure the effect of changes made to improve quality. Methods Application of a prospective longitudinal national cohort data collection that uses algorithms to ensure high data quality (i.e. checks for completeness, plausibility and reliability), and to perform data imaging (Plsek’s p-charts and standardized mortality or morbidity ratio SMR charts). The collected data allows monitoring a study collective of very low birth-weight infants born from 2009 to 2011 by applying a quality cycle following the steps ′guideline – perform - falsify – reform′. Results 2025 VLBW live-births from 2009 to 2011 representing 96.1% of all VLBW live-births in Switzerland display a similar mortality rate but better morbidity rates when compared to other networks. Data quality in general is high but subject to improvement in some units. Seven measurements display quality improvement potential in individual units. The methods used fulfil several international recommendations. Conclusions The Quality Cycle of the Swiss Neonatal Network is a helpful instrument to monitor and gradually help improve the quality of care in a region with high quality standards and low statistical discrimination capacity. PMID:24074151

  8. Water quality success stories: Integrated assessments from the IOOS regional associations and national water quality monitoring network

    USGS Publications Warehouse

    Ragsdale, Rob; Vowinkel, Eric; Porter, Dwayne; Hamilton, Pixie; Morrison, Ru; Kohut, Josh; Connell, Bob; Kelsey, Heath; Trowbridge, Phil

    2011-01-01

    The Integrated Ocean Observing System (IOOS®) Regional Associations and Interagency Partners hosted a water quality workshop in January 2010 to discuss issues of nutrient enrichment and dissolved oxygen depletion (hypoxia), harmful algal blooms (HABs), and beach water quality. In 2007, the National Water Quality Monitoring Council piloted demonstration projects as part of the National Water Quality Monitoring Network (Network) for U.S. Coastal Waters and their Tributaries in three IOOS Regional Associations, and these projects are ongoing. Examples of integrated science-based solutions to water quality issues of major concern from the IOOS regions and Network demonstration projects are explored in this article. These examples illustrate instances where management decisions have benefited from decision-support tools that make use of interoperable data. Gaps, challenges, and outcomes are identified, and a proposal is made for future work toward a multiregional water quality project for beach water quality.

  9. Environmental quality program review

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The transcript of discussions held following formal presentations during sessions 4 and 5 of the program review are presented. Topics covered include global and regional tropospheric research and water quality. Plans for continued study are indicated.

  10. Scientific Framework for Stormwater Monitoring by the Washington State Department of Transportation

    USGS Publications Warehouse

    Sheibley, R.W.; Kelly, V.J.; Wagner, R.J.

    2009-01-01

    The Washington State Department of Transportation municipal stormwater monitoring program, in operation for about 8 years, never has received an external, objective assessment. In addition, the Washington State Department of Transportation would like to identify the standard operating procedures and quality assurance protocols that must be adopted so that their monitoring program will meet the requirements of the new National Pollutant Discharge Elimination System municipal stormwater permit. As a result, in March 2009, the Washington State Department of Transportation asked the U.S. Geological Survey to assess their pre-2009 municipal stormwater monitoring program. This report presents guidelines developed for the Washington State Department of Transportation to meet new permit requirements and regional/national stormwater monitoring standards to ensure that adequate processes and procedures are identified to collect high-quality, scientifically defensible municipal stormwater monitoring data. These include: (1) development of coherent vision and cooperation among all elements of the program; (2) a comprehensive approach for site selection; (3) an effective quality assurance program for field, laboratory, and data management; and (4) an adequate database and data management system.

  11. Monitoring surface water quality using social media in the context of citizen science

    NASA Astrophysics Data System (ADS)

    Zheng, Hang; Hong, Yang; Long, Di; Jing, Hua

    2017-02-01

    Surface water quality monitoring (SWQM) provides essential information for water environmental protection. However, SWQM is costly and limited in terms of equipment and sites. The global popularity of social media and intelligent mobile devices with GPS and photography functions allows citizens to monitor surface water quality. This study aims to propose a method for SWQM using social media platforms. Specifically, a WeChat-based application platform is built to collect water quality reports from volunteers, which have been proven valuable for water quality monitoring. The methods for data screening and volunteer recruitment are discussed based on the collected reports. The proposed methods provide a framework for collecting water quality data from citizens and offer a primary foundation for big data analysis in future research.

  12. A design of wireless sensor networks for a power quality monitoring system.

    PubMed

    Lim, Yujin; Kim, Hak-Man; Kang, Sanggil

    2010-01-01

    Power grids deal with the business of generation, transmission, and distribution of electric power. Recently, interest in power quality in electrical distribution systems has increased rapidly. In Korea, the communication network to deliver voltage, current, and temperature measurements gathered from pole transformers to remote monitoring centers employs cellular mobile technology. Due to high cost of the cellular mobile technology, power quality monitoring measurements are limited and data gathering intervals are large. This causes difficulties in providing the power quality monitoring service. To alleviate the problems, in this paper we present a communication infrastructure to provide low cost, reliable data delivery. The communication infrastructure consists of wired connections between substations and monitoring centers, and wireless connections between pole transformers and substations. For the wireless connection, we employ a wireless sensor network and design its corresponding data forwarding protocol to improve the quality of data delivery. For the design, we adopt a tree-based data forwarding protocol in order to customize the distribution pattern of the power quality information. We verify the performance of the proposed data forwarding protocol quantitatively using the NS-2 network simulator.

  13. A systems approach to modeling Community-Based Environmental Monitoring: a case of participatory water quality monitoring in rural Mexico.

    PubMed

    Burgos, Ana; Páez, Rosaura; Carmona, Estela; Rivas, Hilda

    2013-12-01

    Community-Based Environmental Monitoring (CBM) is a social practice that makes a valuable contribution to environmental management and construction of active societies for sustainable future. However, its documentation and analysis show deficiencies that hinder contrast and comparison of processes and effects. Based on systems approach, this article presents a model of CBM to orient assessment of programs, with heuristic or practical goals. In a focal level, the model comprises three components, the social subject, the object of monitoring, and the means of action, and five processes, data management, social learning, assimilation/decision making, direct action, and linking. Emergent properties were also identified in the focal and suprafocal levels considering community self-organization, response capacity, and autonomy for environmental management. The model was applied to the assessment of a CBM program of water quality implemented in rural areas in Mexico. Attributes and variables (indicators) for components, processes, and emergent properties were selected to measure changes that emerged since the program implementation. The assessment of the first 3 years (2010-2012) detected changes that indicated movement towards the expected results, but it revealed also the need to adjust the intervention strategy and procedures. Components and processes of the model reflected relevant aspects of the CBM in real world. The component called means of action as a key element to transit "from the data to the action." The CBM model offered a conceptual framework with advantages to understand CBM as a socioecological event and to strengthen its implementation under different conditions and contexts.

  14. Northern region landbird monitoring program: a program designed to monitor more than long-term population trends

    Treesearch

    Richard L. Hutto

    2005-01-01

    The Northern Region Landbird Monitoring Program (NRLMP) has been in place for nearly a decade and is designed to allow us to track population trends of numerous landbird species, while at the same time allowing us to investigate the effects of various kinds of land use activity on the occurrence, abundance, or demographics of numerous landbird species. We conduct...

  15. 23 CFR 637.207 - Quality assurance program.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... program. (a) Each STD's quality assurance program shall provide for an acceptance program and an independent assurance (IA) program consisting of the following: (1) Acceptance program. (i) Each STD's... STD shall establish a dispute resolution system. The dispute resolution system shall address the...

  16. 23 CFR 637.207 - Quality assurance program.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... program. (a) Each STD's quality assurance program shall provide for an acceptance program and an independent assurance (IA) program consisting of the following: (1) Acceptance program. (i) Each STD's... STD shall establish a dispute resolution system. The dispute resolution system shall address the...

  17. 23 CFR 637.207 - Quality assurance program.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... program. (a) Each STD's quality assurance program shall provide for an acceptance program and an independent assurance (IA) program consisting of the following: (1) Acceptance program. (i) Each STD's... STD shall establish a dispute resolution system. The dispute resolution system shall address the...

  18. INTEGRATING PROBABILISTIC AND FIXED-SITE MONITORING FOR ROBUST WATER QUALITY ASSESSMENTS

    EPA Science Inventory

    Determining the extent of water-quality degradation, controlling nonpoint sources, and defining allowable amounts of contaminants are important water-quality issues defined in the Clean Water Act that require new monitoring data. Probabilistic, randomized stream water-quality mon...

  19. 43 CFR 12.951 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Organizations Post-Award Requirements § 12.951 Monitoring and reporting program performance. (a) Recipients are... award. Recipients shall monitor subawards to ensure subrecipients have met the audit requirements as...) Recipients shall immediately notify the Federal awarding agency of developments that have a significant...

  20. 22 CFR 518.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... or activity supported by the award. Recipients shall monitor subawards to ensure subrecipients have...) Recipients shall immediately notify the Federal awarding agency of developments that have a significant... ORGANIZATIONS Post-Award Requirements Reports and Records § 518.51 Monitoring and reporting program performance...

  1. 43 CFR 12.951 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Organizations Post-Award Requirements § 12.951 Monitoring and reporting program performance. (a) Recipients are... award. Recipients shall monitor subawards to ensure subrecipients have met the audit requirements as...) Recipients shall immediately notify the Federal awarding agency of developments that have a significant...

  2. 22 CFR 518.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... or activity supported by the award. Recipients shall monitor subawards to ensure subrecipients have...) Recipients shall immediately notify the Federal awarding agency of developments that have a significant... ORGANIZATIONS Post-Award Requirements Reports and Records § 518.51 Monitoring and reporting program performance...

  3. 49 CFR 19.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... or activity supported by the award. Recipients shall monitor subawards to ensure subrecipients have...) Recipients shall immediately notify the Federal awarding agency of developments that have a significant... ORGANIZATIONS Post-Award Requirements Reports and Records § 19.51 Monitoring and reporting program performance...

  4. 43 CFR 12.951 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Organizations Post-Award Requirements § 12.951 Monitoring and reporting program performance. (a) Recipients are... award. Recipients shall monitor subawards to ensure subrecipients have met the audit requirements as...) Recipients shall immediately notify the Federal awarding agency of developments that have a significant...

  5. 43 CFR 12.951 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Organizations Post-Award Requirements § 12.951 Monitoring and reporting program performance. (a) Recipients are... award. Recipients shall monitor subawards to ensure subrecipients have met the audit requirements as...) Recipients shall immediately notify the Federal awarding agency of developments that have a significant...

  6. 22 CFR 518.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... or activity supported by the award. Recipients shall monitor subawards to ensure subrecipients have...) Recipients shall immediately notify the Federal awarding agency of developments that have a significant... ORGANIZATIONS Post-Award Requirements Reports and Records § 518.51 Monitoring and reporting program performance...

  7. 49 CFR 19.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... or activity supported by the award. Recipients shall monitor subawards to ensure subrecipients have...) Recipients shall immediately notify the Federal awarding agency of developments that have a significant... ORGANIZATIONS Post-Award Requirements Reports and Records § 19.51 Monitoring and reporting program performance...

  8. 49 CFR 19.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... or activity supported by the award. Recipients shall monitor subawards to ensure subrecipients have...) Recipients shall immediately notify the Federal awarding agency of developments that have a significant... ORGANIZATIONS Post-Award Requirements Reports and Records § 19.51 Monitoring and reporting program performance...

  9. 49 CFR 19.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... or activity supported by the award. Recipients shall monitor subawards to ensure subrecipients have...) Recipients shall immediately notify the Federal awarding agency of developments that have a significant... ORGANIZATIONS Post-Award Requirements Reports and Records § 19.51 Monitoring and reporting program performance...

  10. 22 CFR 518.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... or activity supported by the award. Recipients shall monitor subawards to ensure subrecipients have...) Recipients shall immediately notify the Federal awarding agency of developments that have a significant... ORGANIZATIONS Post-Award Requirements Reports and Records § 518.51 Monitoring and reporting program performance...

  11. Hydrologic data for the Larimer-Weld regional water-monitoring program, Colorado, 1975-82

    USGS Publications Warehouse

    Blakely, S.R.; Steinheimer, J.T.

    1984-01-01

    The Larimer-Weld, Colorado, regional Monitoring Program was begun in 1976 to provide information on the quality and quantity of the surface-water resources in the area. Three stations on the big Thompson River and five stations on the Cache La Poudre River were selected for a data-collection network. Four previously established stations were added to complete the data-collection network: Horsetooth Reservoir, Joe Wright Creek above and below Joe Wright Reservoir, and Michigan River near Cameron Pass. Station description, location, and period of record are given for each station. A statistical summary of the water-quality data for each station is tabulated. Frequency of occurrence is given at the 95th, 75th, 50th, and 25th percentiles. Monthly water-quality data and daily average streamflow data are tabulated for each streamflow station for which this data was collected; Monthly contents data are presented for Horsetooth Reservoir. All data tabulated and summarized are from the period October 1, 1975, through September 30, 1982. (USGS)

  12. Yucca Mountain Biological Resources Monitoring Program; Annual report, FY91

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1992-01-01

    The US Department of Energy (DOE) is required by the Nuclear Waste Policy Act of 1982 (as amended in 1987) to study and characterize Yucca Mountain as a possible site for a geologic repository for high-level nuclear waste. During site characterization, the DOE will conduct a variety of geotechnical, geochemical, geological, and hydrological studies to determine the suitability of Yucca Mountain as a repository. To ensure that site characterization activities (SCA) do not adversely affect the Yucca Mountain area, an environmental program has been implemented to monitor and mitigate potential impacts and to ensure that activities comply with applicable environmentalmore » regulations. This report describes the activities and accomplishments during fiscal year 1991 (FY91) for six program areas within the Terrestrial Ecosystem component of the YMP environmental program. The six program areas are Site Characterization Activities Effects, Desert Tortoises, Habitat Reclamation, Monitoring and Mitigation, Radiological Monitoring, and Biological Support.« less

  13. Yucca Mountain biological resources monitoring program; Annual report FY92

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1993-02-01

    The US Department of Energy (DOE) is required by the Nuclear Waste Policy Act of 1982 (as amended in 1987) to study and characterize Yucca Mountain as a potential site for a geologic repository for high-level nuclear waste. During site characterization, the DOE will conduct a variety of geotechnical, geochemical, geological, and hydrological studies to determine the suitability of Yucca Mountain as a potential repository. To ensure that site characterization activities (SCA) do not adversely affect the environment at Yucca Mountain, an environmental program has been implemented to monitor and mitigate potential impacts and ensure activities comply with applicable environmentalmore » regulations. This report describes the activities and accomplishments of EG&G Energy Measurements, Inc. (EG&G/EM) during fiscal year 1992 (FY92) for six program areas within the Terrestrial Ecosystem component of the YMP environmental program. The six program areas are Site Characterization Effects, Desert Tortoises, Habitat Reclamation, Monitoring and Mitigation, Radiological Monitoring, and Biological Support.« less

  14. Design Exception In-Service Monitoring Program Development

    DOT National Transportation Integrated Search

    2017-05-01

    This study evaluates various possible program designs for in-service monitoring of design exceptions (DEs) for the Georgia Department of Transportation. The study recommends a multitier stepwise approach to the evaluation of DEs. Specifically, the pr...

  15. 40 CFR 58.61 - Monitoring other pollutants.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Monitoring other pollutants. 58.61 Section 58.61 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) AMBIENT AIR QUALITY SURVEILLANCE Federal Monitoring § 58.61 Monitoring other pollutants. The...

  16. 40 CFR 58.13 - Monitoring network completion.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 6 2012-07-01 2012-07-01 false Monitoring network completion. 58.13 Section 58.13 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) AMBIENT AIR QUALITY SURVEILLANCE Monitoring Network § 58.13 Monitoring network completion. (a...

  17. 40 CFR 58.13 - Monitoring network completion.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 6 2014-07-01 2014-07-01 false Monitoring network completion. 58.13 Section 58.13 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) AMBIENT AIR QUALITY SURVEILLANCE Monitoring Network § 58.13 Monitoring network completion. (a...

  18. 40 CFR 58.13 - Monitoring network completion.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 6 2013-07-01 2013-07-01 false Monitoring network completion. 58.13 Section 58.13 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) AMBIENT AIR QUALITY SURVEILLANCE Monitoring Network § 58.13 Monitoring network completion. (a...

  19. Spectral Band Characterization for Hyperspectral Monitoring of Water Quality

    NASA Technical Reports Server (NTRS)

    Vermillion, Stephanie C.; Raqueno, Rolando; Simmons, Rulon

    2001-01-01

    A method for selecting the set of spectral characteristics that provides the smallest increase in prediction error is of interest to those using hyperspectral imaging (HSI) to monitor water quality. The spectral characteristics of interest to these applications are spectral bandwidth and location. Three water quality constituents of interest that are detectable via remote sensing are chlorophyll (CHL), total suspended solids (TSS), and colored dissolved organic matter (CDOM). Hyperspectral data provides a rich source of information regarding the content and composition of these materials, but often provides more data than an analyst can manage. This study addresses the spectral characteristics need for water quality monitoring for two reasons. First, determination of the greatest contribution of these spectral characteristics would greatly improve computational ease and efficiency. Second, understanding the spectral capabilities of different spectral resolutions and specific regions is an essential part of future system development and characterization. As new systems are developed and tested, water quality managers will be asked to determine sensor specifications that provide the most accurate and efficient water quality measurements. We address these issues using data from the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) and a set of models to predict constituent concentrations.

  20. 41 CFR 109-45.1002-3 - Precious metals recovery program monitor.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... program monitor. 109-45.1002-3 Section 109-45.1002-3 Public Contracts and Property Management Federal... UTILIZATION AND DISPOSAL 45-SALE, ABANDONMENT, OR DESTRUCTION OF PERSONAL PROPERTY 45.10-Recovery of Precious Metals § 109-45.1002-3 Precious metals recovery program monitor. The DPMO shall be the precious metals...

  1. Five-Star Schools: Defining Quality in Early Childhood Programs

    ERIC Educational Resources Information Center

    Hertzog, Nancy B.

    2012-01-01

    Hakeem, Emily, Jose, and Latisha are all entering preschool in the fall. Their mothers are looking for the highest quality early childhood program they can find. Is there a guide for them to find a five-star program? Are all certified or accredited programs of equal quality? How do these parents and guardians know what defines quality in early…

  2. Heart failure patients utilizing an electric home monitor: What effects does heart failure have on their quality of life?

    NASA Astrophysics Data System (ADS)

    Simuel, Gloria J.

    Heart Failure continues to be a major public health problem associated with high mortality and morbidity. Heart Failure is the leading cause of hospitalization for persons older than 65 years, has a poor prognosis and is associated with poor quality of life. More than 5.3 million American adults are living with heart failure. Despite maximum medical therapy and frequent hospitalizations to stabilize their condition, one in five heart failure patients die within the first year of diagnosis. Several disease-management programs have been proposed and tested to improve the quality of heart failure care. Studies have shown that hospital admissions and emergency room visits decrease with increased nursing interventions in the home and community setting. An alternative strategy for promoting self-management of heart failure is the use of electronic home monitoring. The purpose of this study was to examine what effects heart failure has on patient's quality of life that had been monitoring on an electronic home monitor longer than 2 months. Twenty-one questionnaires were given to patients utilizing an electronic home monitor by their home health agency nurse. Eleven patients completed the questionnaire. The findings showed that there is some deterioration in quality of life with more association with the physical aspects of life than with the emotional aspects of life, which probably was due to the small sample size. There was no significant difference in readmission rates in patients utilizing an electronic home monitor. Further research is needed with a larger population of patients with chronic heart failure and other chronic diseases which may provide more data, and address issues such as patient compliance with self-care, impact of heart failure on patient's quality of life, functional capacity, and heart failure patient's utilization of the emergency rooms and hospital. Telemonitoring holds promise for improving the self-care abilities of persons with HF.

  3. Participative approach to elicit water quality monitoring needs from stakeholder groups - An application of integrated watershed management.

    PubMed

    Behmel, S; Damour, M; Ludwig, R; Rodriguez, M J

    2018-07-15

    Water quality monitoring programs (WQMPs) must be based on monitoring objectives originating from the real knowledge needs of all stakeholders in a watershed and users of the resource. This paper proposes a participative approach to elicit knowledge needs and preferred modes of communication from citizens and representatives of organized stakeholders (ROS) on water quality and quantity issues. The participative approach includes six steps and is adaptable and transferable to different types of watersheds. These steps are: (1) perform a stakeholder analysis; (2) conduct an adaptable survey accompanied by a user-friendly public participation geographical information system (PPGIS); (3) hold workshops to meet with ROS to inform them of the results of the survey and PPGIS; discuss attainment of past monitoring objectives; exchange views on new knowledge needs and concerns on water quality and quantity; (4) meet with citizens to obtain the same type of input (as from ROS); (5) analyze the data and information collected to identify new knowledge needs and modes of communication and (6) identify, in collaboration with the individuals in charge of the WQMPs, the short-, medium- and long-term monitoring objectives and communication strategies to be pursued. The participative approach was tested on two distinct watersheds in the province of Quebec, Canada. It resulted in a series of optimization objectives of the existing WQMPs, new monitoring objectives and recommendations regarding communication strategies of the WQMPs' results. The results of this study show that the proposed methodology is appreciated by all parties and that the outcomes and monitoring objectives are acceptable. We also conclude that successful integrated watershed management is a question of scale, and that every aspect of integrated watershed management needs to be adapted to the surface watershed, the groundwater watershed (aquifers) and the human catchment area. Copyright © 2018 Elsevier Ltd. All

  4. Community drinking water quality monitoring data: utility for public health research and practice.

    PubMed

    Jones, Rachael M; Graber, Judith M; Anderson, Robert; Rockne, Karl; Turyk, Mary; Stayner, Leslie T

    2014-01-01

    Environmental Public Health Tracking (EPHT) tracks the occurrence and magnitude of environmental hazards and associated adverse health effects over time. The EPHT program has formally expanded its scope to include finished drinking water quality. Our objective was to describe the features, strengths, and limitations of using finished drinking water quality data from community water systems (CWSs) for EPHT applications, focusing on atrazine and nitrogen compounds in 8 Midwestern states. Water quality data were acquired after meeting with state partners and reviewed and merged for analysis. Data and the coding of variables, particularly with respect to censored results (nondetects), were not standardized between states. Monitoring frequency varied between CWSs and between atrazine and nitrates, but this was in line with regulatory requirements. Cumulative distributions of all contaminants were not the same in all states (Peto-Prentice test P < .001). Atrazine results were highly censored in all states (76.0%-99.3%); higher concentrations were associated with increased measurement frequency and surface water as the CWS source water type. Nitrate results showed substantial state-to-state variability in censoring (20.5%-100%) and in associations between concentrations and the CWS source water type. Statistical analyses of these data are challenging due to high rates of censoring and uncertainty about the appropriateness of parametric assumptions for time-series data. Although monitoring frequency was consistent with regulations, the magnitude of time gaps coupled with uncertainty about CWS service areas may limit linkage with health outcome data.

  5. South Asia transboundary water quality monitoring workshop summary report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Betsill, Jeffrey David; Littlefield, Adriane C.; Luetters, Frederick O.

    2003-04-01

    The Cooperative Monitoring Center (CMC) promotes collaborations among scientists and researchers in several regions as a means of achieving common regional security objectives. To promote cooperation in South Asia on environmental research, an international working group made up of participants from Bangladesh, India, Nepal, Pakistan, and the United States convened in Kathmandu, Nepal, from February 17-23,2002. The workshop was held to further develop the South Asia Transboundary Water Quality Monitoring (SATWQM) project. The project is sponsored in part by the CMC located at Sandia National Laboratories in Albuquerque, New Mexico through funding provided by the US. Department of State, Regionalmore » Environmental Affairs Office, American Embassy, Kathmandu, Nepal, and the National Nuclear Security Administration's (NNSA) Office of Nonproliferation and National Security. This report summarizes the SATWQM project, the workshop objectives, process and results. The long-term interests of the participants are to develop systems for sharing regional environmental information as a means of building confidence and improving relations among South Asian countries. The more immediate interests of the group are focused on activities that foster regional sharing of water quality data in the Ganges and Indus River basins. Issues of concern to the SATWQM network participants include studying the impacts from untreated sewage and industrial effluents, agricultural run-off, salinity increases in fresh waters, the siltation and shifting of river channels, and the environmental degradation of critical habitats such as wetlands, protected forests, and endangered aquatic species conservation areas. The workshop focused on five objectives: (1) a deepened understanding of the partner organizations involved; (2) garnering the support of additional regional and national government and non-government organizations in South Asia involved in river water quality monitoring; (3

  6. Louisiana offshore terminal authority environmental monitoring

    DOT National Transportation Integrated Search

    2002-09-01

    The current Louisiana Offshore Oil Port (LOOP) monitoring program includes seasonal monitoring of aquatic and marine resources, sediment composition, and water quality on a five-year cycle. These data provide an update to the existing long-term LOOP ...

  7. 20 CFR 435.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ..., program, subaward, function or activity supported by the award. Recipients must monitor subawards to...) Recipients must immediately notify SSA of developments that have a significant impact on the award-supported... ORGANIZATIONS, AND COMMERCIAL ORGANIZATIONS Post-Award Requirements Reports and Records § 435.51 Monitoring and...

  8. 20 CFR 435.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ..., program, subaward, function or activity supported by the award. Recipients must monitor subawards to...) Recipients must immediately notify SSA of developments that have a significant impact on the award-supported... ORGANIZATIONS, AND COMMERCIAL ORGANIZATIONS Post-Award Requirements Reports and Records § 435.51 Monitoring and...

  9. 20 CFR 435.51 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ..., program, subaward, function or activity supported by the award. Recipients must monitor subawards to...) Recipients must immediately notify SSA of developments that have a significant impact on the award-supported... ORGANIZATIONS, AND COMMERCIAL ORGANIZATIONS Post-Award Requirements Reports and Records § 435.51 Monitoring and...

  10. Integration of structural health monitoring solutions onto commercial aircraft via the Federal Aviation Administration structural health monitoring research program

    NASA Astrophysics Data System (ADS)

    Swindell, Paul; Doyle, Jon; Roach, Dennis

    2017-02-01

    The Federal Aviation Administration (FAA) started a research program in structural health monitoring (SHM) in 2011. The program's goal was to understand the technical gaps of implementing SHM on commercial aircraft and the potential effects on FAA regulations and guidance. The program evolved into a demonstration program consisting of a team from Sandia National Labs Airworthiness Assurance NDI Center (AANC), the Boeing Corporation, Delta Air Lines, Structural Monitoring Systems (SMS), Anodyne Electronics Manufacturing Corp (AEM) and the FAA. This paper will discuss the program from the selection of the inspection problem, the SHM system (Comparative Vacuum Monitoring-CVM) that was selected as the inspection solution and the testing completed to provide sufficient data to gain the first approved use of an SHM system for routine maintenance on commercial US aircraft.

  11. Perceptions and misconceptions regarding the Joint Commission's view of quality monitoring.

    PubMed

    Patterson, C H

    1989-10-01

    The Joint Commission recently has revised its hospital standards for infection control to reflect more accurately current state-of-the-art practices. In addition, the Joint Commission's Agenda for Change initiatives include the development of clinical indicators; one of the topics that will be included in those clinical indicator sets will be infection control. How the hospital chooses to organize itself to conduct the historically required monitoring and evaluation of clinical patient care currently required by the standards of the Joint Commission is at the option of the hospital. How the hospital will organize and collect data specific to infection control indicators yet to be developed by the Joint Commission has not been determined and will not be defined until specific research and development projects are completed. The hospital is expected to have in place infection prevention, surveillance, and control programs; it also is expected to have in place a quality assurance program that focuses not only on solving identified problems but also on the improvement of patient care quality. How the hospitals organize and/or integrate these activities is also at its option. It is expected that qualified professionals will direct and enforce infection prevention, surveillance, and control practices; indicators for infection control can provide data that will help assess the relative success of those practices and activities. The Joint Commission is not developing the capability to judge, on its own part, the actual quality of care provided by an organization seeking accreditation. Rather, the Joint Commission is committed to developing more accurate means to evaluate the structures, processes, and outcomes of diagnosis and treatment activities, as well as their interrelationships. Clinical excellence is supported by quality in the organizational environment and the managerial and leadership contexts within which patient care is delivered. Both clinical and

  12. Lot quality assurance sampling to monitor supplemental immunization activity quality: an essential tool for improving performance in polio endemic countries.

    PubMed

    Brown, Alexandra E; Okayasu, Hiromasa; Nzioki, Michael M; Wadood, Mufti Z; Chabot-Couture, Guillaume; Quddus, Arshad; Walker, George; Sutter, Roland W

    2014-11-01

    Monitoring the quality of supplementary immunization activities (SIAs) is a key tool for polio eradication. Regular monitoring data, however, are often unreliable, showing high coverage levels in virtually all areas, including those with ongoing virus circulation. To address this challenge, lot quality assurance sampling (LQAS) was introduced in 2009 as an additional tool to monitor SIA quality. Now used in 8 countries, LQAS provides a number of programmatic benefits: identifying areas of weak coverage quality with statistical reliability, differentiating areas of varying coverage with greater precision, and allowing for trend analysis of campaign quality. LQAS also accommodates changes to survey format, interpretation thresholds, evaluations of sample size, and data collection through mobile phones to improve timeliness of reporting and allow for visualization of campaign quality. LQAS becomes increasingly important to address remaining gaps in SIA quality and help focus resources on high-risk areas to prevent the continued transmission of wild poliovirus. © Crown copyright 2014.

  13. Progress report on the ground-water, surface-water, and quality- of-water monitoring program, Black Mesa Area, northeastern Arizona; 1987-88

    USGS Publications Warehouse

    Hart, R.J.; Sottilare, J.P.

    1988-01-01

    The Black Mesa, Arizona, monitoring program is designed to determine long-term effects on the water resources of the area resulting from withdrawals of groundwater from the N aquifer by the strip-mining operation of Peabody Coal Company. Withdrawals by Peabody Coal Company increased from 95 acre-ft in 1968 to 3 ,832 acre-ft in 1987. The N aquifer is an important source of water in the 5,400-sq-mi Black Mesa area on the Navajo and Hopi Indian Reservations. Water levels in the confined area of the aquifer declined as much as 95.1 ft near Keams Canyon from 1965 to 1988. Part of the decline in the measured municipal wells may be due to local pumping. During 1965-88, water levels in wells that tap the unconfined area of the aquifer have not declined significantly and have risen in many areas. Chemical analyses indicate no significant changes in the quality of water from wells that tap the N aquifer or from springs that discharge from several stratigraphic units, including the N aquifer, since pumping began at the mine. (USGS)

  14. Assessment of citizen group court monitoring programs

    DOT National Transportation Integrated Search

    1987-03-01

    The purpose of the study is to determine whether the presence of a citizen group court monitoring program within a jurisdiction influences the disposition of driving while intoxicated cases. Initial research identified a number of citizens group cour...

  15. Study of weld quality real-time monitoring system for auto-body assembly

    NASA Astrophysics Data System (ADS)

    Xu, Jun; Li, Yong-Bing; Chen, Guan-Long

    2005-12-01

    Resistance spot welding (RSW) is widely used for the auto-body assembly in automotive industry. But RSW suffers from a major problem of inconsistent quality from weld to weld. The major problem is the complexity of the basic process that may involve material coatings, electrode force, electrode wear, fit up, etc. Therefore weld quality assurance is still a big challenge and goal. Electrode displacement has proved to be a particularly useful signal which correlates well with weld quality. This paper introduces a novel auto-body spot weld quality monitoring system which uses electrode displacement as the quality parameter. This system chooses the latest laser displacement sensor with high resolution to measure the real-time electrode displacement. It solves the interference problem of sensor mounting by designing special fixture, and can be successfully applied on the portable welding machine. It is capable of evaluating weld quality and making diagnosis of process variations such as surface asperities, shunting, worn electrode and weld expansion with real-time electrode displacement. As proved by application in the workshop, the monitoring system has good stability and reliability, and is qualified for monitoring weld quality in process.

  16. 41 CFR 109-45.1002-3 - Precious metals recovery program monitor.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 41 Public Contracts and Property Management 3 2011-01-01 2011-01-01 false Precious metals recovery program monitor. 109-45.1002-3 Section 109-45.1002-3 Public Contracts and Property Management Federal... Metals § 109-45.1002-3 Precious metals recovery program monitor. The DPMO shall be the precious metals...

  17. The Savannah River Site's groundwater monitoring program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1991-05-06

    The Environmental Protection Department/Environmental Monitoring Section (EPD/EMS) administers the Savannah River Site's (SRS) Groundwater Monitoring Program. During third quarter 1990 (July through September) EPD/EMS conducted routine sampling of monitoring wells and drinking water locations. EPD/EMS established two sets of flagging criteria in 1986 to assist in the management of sample results. The flagging criteria do not define contamination levels; instead they aid personnel in sample scheduling, interpretation of data, and trend identification. The flagging criteria are based on detection limits, background levels in SRS groundwater, and drinking water standards. All analytical results from third quarter 1990 are listed in thismore » report, which is distributed to all site custodians. One or more analytes exceeded Flag 2 in 87 monitoring well series. Analytes exceeded Flat 2 for the first since 1984 in 14 monitoring well series. In addition to groundwater monitoring, EPD/EMS collected drinking water samples from SRS drinking water systems supplied by wells. The drinking water samples were analyzed for radioactive constituents.« less

  18. Understanding Program Monitoring: The Relationships among Outcomes, Indicators, Measures, and Targets. REL 2014-011

    ERIC Educational Resources Information Center

    Malone, Nolan; Mark, Lauren; Narayan, Krishna

    2014-01-01

    This guide offers educators, program managers, administrators, and researchers a resource for building capacity for monitoring program outcomes. It provides concise definitions of program monitoring components and a framework for assessing program progress. Examples demonstrate the relationships among program components: outcomes, indicators,…

  19. MAINTAINING DATA QUALITY IN THE PERFORMANCE OF A LARGE SCALE INTEGRATED MONITORING EFFORT

    EPA Science Inventory

    Macauley, John M. and Linda C. Harwell. In press. Maintaining Data Quality in the Performance of a Large Scale Integrated Monitoring Effort (Abstract). To be presented at EMAP Symposium 2004: Integrated Monitoring and Assessment for Effective Water Quality Management, 3-7 May 200...

  20. 45 CFR 602.40 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 45 Public Welfare 3 2014-10-01 2014-10-01 false Monitoring and reporting program performance. 602.40 Section 602.40 Public Welfare Regulations Relating to Public Welfare (Continued) NATIONAL SCIENCE... inspections and certified percentage-of-completion data are relied on heavily by Federal agencies to monitor...

  1. 45 CFR 602.40 - Monitoring and reporting program performance.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 45 Public Welfare 3 2012-10-01 2012-10-01 false Monitoring and reporting program performance. 602.40 Section 602.40 Public Welfare Regulations Relating to Public Welfare (Continued) NATIONAL SCIENCE... inspections and certified percentage-of-completion data are relied on heavily by Federal agencies to monitor...

  2. Trends in Surface-Water Quality at Selected Ambient-Monitoring Network Stations in Kentucky, 1979-2004

    USGS Publications Warehouse

    Crain, Angela S.; Martin, Gary R.

    2009-01-01

    Increasingly complex water-management decisions require water-quality monitoring programs that provide data for multiple purposes, including trend analyses, to detect improvement or deterioration in water quality with time. Understanding surface-water-quality trends assists resource managers in identifying emerging water-quality concerns, planning remediation efforts, and evaluating the effectiveness of the remediation. This report presents the results of a study conducted by the U.S. Geological Survey, in cooperation with the Kentucky Energy and Environment Cabinet-Kentucky Division of Water, to analyze and summarize long-term water-quality trends of selected properties and water-quality constituents in selected streams in Kentucky's ambient stream water-quality monitoring network. Trends in surface-water quality for 15 properties and water-quality constituents were analyzed at 37 stations with drainage basins ranging in size from 62 to 6,431 square miles. Analyses of selected physical properties (temperature, specific conductance, pH, dissolved oxygen, hardness, and suspended solids), for major ions (chloride and sulfate), for selected metals (iron and manganese), for nutrients (total phosphorus, total nitrogen, total Kjeldahl nitrogen, nitrite plus nitrate), and for fecal coliform were compiled from the Commonwealth's ambient water-quality monitoring network. Trend analyses were completed using the S-Plus statistical software program S-Estimate Trend (S-ESTREND), which detects trends in water-quality data. The trend-detection techniques supplied by this software include the Seasonal Kendall nonparametric methods for use with uncensored data or data censored with only one reporting limit and the Tobit-regression parametric method for use with data censored with multiple reporting limits. One of these tests was selected for each property and water-quality constituent and applied to all station records so that results of the trend procedure could be compared among

  3. Establishing monitoring programs for travel time reliability.

    DOT National Transportation Integrated Search

    2014-01-01

    Within the second Strategic Highway Research Program (SHRP 2), Project L02 focused on creating a suite of methods by which transportation agencies could monitor and evaluate travel time reliability. Creation of the methods also produced an improved u...

  4. Curriculum-Based Measurement of Oral Reading: Quality of Progress Monitoring Outcomes

    ERIC Educational Resources Information Center

    Christ, Theodore J.; Zopluoglu, Cengiz; Long, Jeffery D.; Monaghen, Barbara D.

    2012-01-01

    Curriculum-based measurement of oral reading (CBM-R) is frequently used to set student goals and monitor student progress. This study examined the quality of growth estimates derived from CBM-R progress monitoring data. The authors used a linear mixed effects regression (LMER) model to simulate progress monitoring data for multiple levels of…

  5. An Overview of the Ontario Forest Bird Monitoring Program in Canada

    Treesearch

    Daniel A. Welsh

    1995-01-01

    In 1987, the Canadian Wildlife Service (Ontario Region) initiated a program to inventory and monitor trends in forest birds. The Forest Bird Monitoring Program (FBMP) was designed to describe changes in numbers over time for all forest songbirds, to develop a habitat-specific baseline inventory of forest birds (species composition and relative abundance), and to...

  6. Development and evaluation of a helicopter-borne water-quality monitoring system

    NASA Technical Reports Server (NTRS)

    Wallace, J. W.; Jordan, R. A.; Flynn, J.; Thomas, R. W.

    1978-01-01

    A small, helicopter-borne water-quality monitoring package is being developed by the NASA/EPA using a combination of basic in situ water quality sensors and physical sample collector technology. The package is a lightweight system which can be carried and operated by one person as a passenger in a small helicopter typically available by rental at commercial airports. Real-time measurements are made by suspending the water quality monitoring package with a cable from the hovering helicopter. Designed primarily for use in rapidly assessing hazardous material spills in inland and coastal zone water bodies, the system can survey as many as 20 data stations up to 1.5 kilometers apart in 1 hour. The system provides several channels of sensor data and allows for the addition of future sensors. The system will also collect samples from selected sites with sample collection on command. An EPA Spill Response Team member can easily transport, deploy, and operate the water quality monitoring package to determine the distribution, movement, and concentration of the spilled material in the water body.

  7. Change in Adverse Events After Enrollment in the National Surgical Quality Improvement Program: A Systematic Review and Meta-Analysis.

    PubMed

    Montroy, Joshua; Breau, Rodney H; Cnossen, Sonya; Witiuk, Kelsey; Binette, Andrew; Ferrier, Taylor; Lavallée, Luke T; Fergusson, Dean A; Schramm, David

    2016-01-01

    The American College of Surgeons' National Surgical Quality Improvement Program (NSQIP) is the first nationally validated, risk-adjusted, outcomes-based program to measure and compare the quality of surgical care across North America. Participation in this program may provide an opportunity to reduce the incidence of adverse events related to surgery. A systematic review of the literature was performed. MedLine, EMBASE and PubMed were searched for studies relevant to NSQIP. Patient characteristics, intervention, and primary outcome measures were abstracted. The intervention was participation in NSQIP and monitoring of Individual Site Summary Reports with or without implementation of a quality improvement program. The outcomes of interest were change in peri-operative adverse events and mortality represented by pooled risk ratios (pRR) and 95% confidence intervals (CI). Eleven articles reporting on 35 health care institutions were included. Nine (82%) of the eleven studies implemented a quality improvement program. Minimal improvements in superficial (pRR 0.81; 95% CI 0.72-0.91), deep (pRR 0.82; 95% CI0.64-1.05) and organ space (pRR 1.15; 95% CI 0.96-1.37) infections were observed at centers that did not institute a quality improvement program. However, centers that reported formal interventions for the prevention and treatment of infections observed substantial improvements (superficial pRR 0.55, 95% CI 0.39-0.77; deep pRR 0.61, 95% CI 0.50-0.75, and organ space pRR 0.60, 95% CI 0.50-0.71). Studies evaluating other adverse events noted decreased incidence following NSQIP participation and implementation of a formal quality improvement program. These data suggest that NSQIP is effective in reducing surgical morbidity. Improvement in surgical quality appears to be more marked at centers that implemented a formal quality improvement program directed at the reduction of specific morbidities.

  8. A framework for evaluating and designing citizen science programs for natural resources monitoring.

    PubMed

    Chase, Sarah K; Levine, Arielle

    2016-06-01

    We present a framework of resource characteristics critical to the design and assessment of citizen science programs that monitor natural resources. To develop the framework we reviewed 52 citizen science programs that monitored a wide range of resources and provided insights into what resource characteristics are most conducive to developing citizen science programs and how resource characteristics may constrain the use or growth of these programs. We focused on 4 types of resource characteristics: biophysical and geographical, management and monitoring, public awareness and knowledge, and social and cultural characteristics. We applied the framework to 2 programs, the Tucson (U.S.A.) Bird Count and the Maui (U.S.A.) Great Whale Count. We found that resource characteristics such as accessibility, diverse institutional involvement in resource management, and social or cultural importance of the resource affected program endurance and success. However, the relative influence of each characteristic was in turn affected by goals of the citizen science programs. Although the goals of public engagement and education sometimes complimented the goal of collecting reliable data, in many cases trade-offs must be made between these 2 goals. Program goals and priorities ultimately dictate the design of citizen science programs, but for a program to endure and successfully meet its goals, program managers must consider the diverse ways that the nature of the resource being monitored influences public participation in monitoring. © 2016 Society for Conservation Biology.

  9. Population size influences amphibian detection probability: implications for biodiversity monitoring programs.

    PubMed

    Tanadini, Lorenzo G; Schmidt, Benedikt R

    2011-01-01

    Monitoring is an integral part of species conservation. Monitoring programs must take imperfect detection of species into account in order to be reliable. Theory suggests that detection probability may be determined by population size but this relationship has not yet been assessed empirically. Population size is particularly important because it may induce heterogeneity in detection probability and thereby cause bias in estimates of biodiversity. We used a site occupancy model to analyse data from a volunteer-based amphibian monitoring program to assess how well different variables explain variation in detection probability. An index to population size best explained detection probabilities for four out of six species (to avoid circular reasoning, we used the count of individuals at a previous site visit as an index to current population size). The relationship between the population index and detection probability was positive. Commonly used weather variables best explained detection probabilities for two out of six species. Estimates of site occupancy probabilities differed depending on whether the population index was or was not used to model detection probability. The relationship between the population index and detectability has implications for the design of monitoring and species conservation. Most importantly, because many small populations are likely to be overlooked, monitoring programs should be designed in such a way that small populations are not overlooked. The results also imply that methods cannot be standardized in such a way that detection probabilities are constant. As we have shown here, one can easily account for variation in population size in the analysis of data from long-term monitoring programs by using counts of individuals from surveys at the same site in previous years. Accounting for variation in population size is important because it can affect the results of long-term monitoring programs and ultimately the conservation of

  10. Apparatus and method for acoustic monitoring of steam quality and flow

    DOEpatents

    Sinha, Dipen N.; Pantea, Cristian

    2016-09-13

    An apparatus and method for noninvasively monitoring steam quality and flow and in pipes or conduits bearing flowing steam, are described. By measuring the acoustic vibrations generated in steam-carrying conduits by the flowing steam either by direct contact with the pipe or remotely thereto, converting the measured acoustic vibrations into a frequency spectrum characteristic of the natural resonance vibrations of the pipe, and monitoring the amplitude and/or the frequency of one or more chosen resonance frequencies, changes in the steam quality in the pipe are determined. The steam flow rate and the steam quality are inversely related, and changes in the steam flow rate are calculated from changes in the steam quality once suitable calibration curves are obtained.

  11. Developing a multidisciplinary robotic surgery quality assessment program.

    PubMed

    Gonsenhauser, Iahn; Abaza, Ronney; Mekhjian, Hagop; Moffatt-Bruce, Susan D

    2012-01-01

    The objective of this study was to test the feasibility of a novel quality-improvement (QI) program designed to incorporate multiple robotic surgical sub-specialties in one health care system. A robotic surgery quality assessment program was developed by The Ohio State University College of Medicine (OSUMC) in conjunction with The Ohio State University Medical Center Quality Improvement and Operations Department. A retrospective review of cases was performed using data interrogated from the OSUMC Information Warehouse from January 2007 through August 2009. Robotic surgery cases (n=2200) were assessed for operative times, length of stay (LOS), conversions, returns to surgery, readmissions and cancellations as potential quality indicators. An actionable and reproducible framework for the quality measurement and assessment of a multidisciplinary and interdepartmental robotic surgery program was successfully completed demonstrating areas for improvement opportunities. This report supports that standard quality indicators can be applied to multiple specialties within a health care system to develop a useful quality tracking and assessment tool in the highly specialized area of robotic surgery. © 2012 National Association for Healthcare Quality.

  12. Introduction to:Forest health monitoring program

    Treesearch

    Mark J. Ambrose

    2009-01-01

    This annual technical report is a product of the Forest Health Monitoring (FHM) Program. The report provides information about a variety of issues relating to forest health at a national scale. FHM national reports have the dual focus of presenting analyses of the latest available data and showcasing innovative techniques for analyzing forest health data. The report is...

  13. Small-scale monitoring - can it be integrated with large-scale programs?

    Treesearch

    C. M. Downes; J. Bart; B. T. Collins; B. Craig; B. Dale; E. H. Dunn; C. M. Francis; S. Woodley; P. Zorn

    2005-01-01

    There are dozens of programs and methodologies for monitoring and inventory of bird populations, differing in geographic scope, species focus, field methods and purpose. However, most of the emphasis has been placed on large-scale monitoring programs. People interested in assessing bird numbers and long-term trends in small geographic areas such as a local birding area...

  14. How Can Remote Sensing Be Used for Water Quality Monitoring?

    EPA Science Inventory

    “How can remote sensing address information needs and gaps in water quality and quantity management?” was a workshop convened during the biennial National Water Quality Monitoring Conference 2014, held in Cincinnati, OH. The focus of this workshop was to provide an o...

  15. Optimal Design of Air Quality Monitoring Network and its Application in an Oil Refinery Plant: An Approach to Keep Health Status of Workers.

    PubMed

    ZoroufchiBenis, Khaled; Fatehifar, Esmaeil; Ahmadi, Javad; Rouhi, Alireza

    2015-01-01

    Industrial air pollution is a growing challenge to humane health, especially in developing countries, where there is no systematic monitoring of air pollution. Given the importance of the availability of valid information on population exposure to air pollutants, it is important to design an optimal Air Quality Monitoring Network (AQMN) for assessing population exposure to air pollution and predicting the magnitude of the health risks to the population. A multi-pollutant method (implemented as a MATLAB program) was explored for configur-ing an AQMN to detect the highest level of pollution around an oil refinery plant. The method ranks potential monitoring sites (grids) according to their ability to represent the ambient concentration. The term of cluster of contiguous grids that exceed a threshold value was used to calculate the Station Dosage. Selection of the best configuration of AQMN was done based on the ratio of a sta-tion's dosage to the total dosage in the network. Six monitoring stations were needed to detect the pollutants concentrations around the study area for estimating the level and distribution of exposure in the population with total network efficiency of about 99%. An analysis of the design procedure showed that wind regimes have greatest effect on the location of monitoring stations. The optimal AQMN enables authorities to implement an effective program of air quality management for protecting human health.

  16. Water-quality conditions and an evaluation of ground- and surface-water sampling programs in the Livermore-Amador Valley, California

    USGS Publications Warehouse

    Sorenson, S.K.; Cascos, P.V.; Glass, R.L.

    1984-01-01

    A program to monitor the ground- and surface water quality in the Livermore-Amador Valley has been operated since 1976. As of 1982, this monitoring network consisted of approximately 130 wells, about 100 of which were constructed specifically for this program, and 9 surface water stations. Increased demand on the groundwater for municipal and industrial water supply in the past has caused a decline in water levels and a gradual buildup of salts from natural surface-water recharge and land disposal of treated wastewater from waste treatment plants. Results of this study identify the salt buildup to be the major problem with the groundwater quality. Established water quality objectives for dissolved solids are exceeded in 52 of 130 wells. Concentrations of dissolved nitrate are also in excess of basin objectives and health standards. Water quality in both surface and groundwater is highly variable areally. Magnesium to calcium magnesium bicarbonate groundwater are found in the areas where most of the high volume municipal wells are located. Large areas of sodium bicarbonate water occur in the northern part of the valley. Except for two stations on Arroyo Las Positas which has sodium chloride water, surface water is mixed-cation bicarbonate water. (USGS)

  17. A low-cost sensing system for cooperative air quality monitoring in urban areas.

    PubMed

    Brienza, Simone; Galli, Andrea; Anastasi, Giuseppe; Bruschi, Paolo

    2015-05-26

    Air quality in urban areas is a very important topic as it closely affects the health of citizens. Recent studies highlight that the exposure to polluted air can increase the incidence of diseases and deteriorate the quality of life. Hence, it is necessary to develop tools for real-time air quality monitoring, so as to allow appropriate and timely decisions. In this paper, we present uSense, a low-cost cooperative monitoring tool that allows knowing, in real-time, the concentrations of polluting gases in various areas of the city. Specifically, users monitor the areas of their interest by deploying low-cost and low-power sensor nodes. In addition, they can share the collected data following a social networking approach. uSense has been tested through an in-field experimentation performed in different areas of a city. The obtained results are in line with those provided by the local environmental control authority and show that uSense can be profitably used for air quality monitoring.

  18. Combining accuracy assessment of land-cover maps with environmental monitoring programs

    USGS Publications Warehouse

    Stehman, S.V.; Czaplewski, R.L.; Nusser, S.M.; Yang, L.; Zhu, Z.

    2000-01-01

    A scientifically valid accuracy assessment of a large-area, land-cover map is expensive. Environmental monitoring programs offer a potential source of data to partially defray the cost of accuracy assessment while still maintaining the statistical validity. In this article, three general strategies for combining accuracy assessment and environmental monitoring protocols are described. These strategies range from a fully integrated accuracy assessment and environmental monitoring protocol, to one in which the protocols operate nearly independently. For all three strategies, features critical to using monitoring data for accuracy assessment include compatibility of the land-cover classification schemes, precisely co-registered sample data, and spatial and temporal compatibility of the map and reference data. Two monitoring programs, the National Resources Inventory (NRI) and the Forest Inventory and Monitoring (FIM), are used to illustrate important features for implementing a combined protocol.

  19. 40 CFR 35.6755 - Monitoring program performance.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 1 2014-07-01 2014-07-01 false Monitoring program performance. 35.6755 Section 35.6755 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER FEDERAL ASSISTANCE STATE AND LOCAL ASSISTANCE Cooperative Agreements and Superfund State Contracts for Superfund...

  20. 40 CFR 35.6755 - Monitoring program performance.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Monitoring program performance. 35.6755 Section 35.6755 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER FEDERAL ASSISTANCE STATE AND LOCAL ASSISTANCE Cooperative Agreements and Superfund State Contracts for Superfund...