Sample records for quality parameters measured

  1. Water quality parameter measurement using spectral signatures

    NASA Technical Reports Server (NTRS)

    White, P. E.

    1973-01-01

    Regression analysis is applied to the problem of measuring water quality parameters from remote sensing spectral signature data. The equations necessary to perform regression analysis are presented and methods of testing the strength and reliability of a regression are described. An efficient algorithm for selecting an optimal subset of the independent variables available for a regression is also presented.

  2. PV cells electrical parameters measurement

    NASA Astrophysics Data System (ADS)

    Cibira, Gabriel

    2017-12-01

    When measuring optical parameters of a photovoltaic silicon cell, precise results bring good electrical parameters estimation, applying well-known physical-mathematical models. Nevertheless, considerable re-combination phenomena might occur in both surface and intrinsic thin layers within novel materials. Moreover, rear contact surface parameters may influence close-area re-combination phenomena, too. Therefore, the only precise electrical measurement approach is to prove assumed cell electrical parameters. Based on theoretical approach with respect to experiments, this paper analyses problems within measurement procedures and equipment used for electrical parameters acquisition within a photovoltaic silicon cell, as a case study. Statistical appraisal quality is contributed.

  3. Measuring saliency in images: which experimental parameters for the assessment of image quality?

    NASA Astrophysics Data System (ADS)

    Fredembach, Clement; Woolfe, Geoff; Wang, Jue

    2012-01-01

    Predicting which areas of an image are perceptually salient or attended to has become an essential pre-requisite of many computer vision applications. Because observers are notoriously unreliable in remembering where they look a posteriori, and because asking where they look while observing the image necessarily in uences the results, ground truth about saliency and visual attention has to be obtained by gaze tracking methods. From the early work of Buswell and Yarbus to the most recent forays in computer vision there has been, perhaps unfortunately, little agreement on standardisation of eye tracking protocols for measuring visual attention. As the number of parameters involved in experimental methodology can be large, their individual in uence on the nal results is not well understood. Consequently, the performance of saliency algorithms, when assessed by correlation techniques, varies greatly across the literature. In this paper, we concern ourselves with the problem of image quality. Specically: where people look when judging images. We show that in this case, the performance gap between existing saliency prediction algorithms and experimental results is signicantly larger than otherwise reported. To understand this discrepancy, we rst devise an experimental protocol that is adapted to the task of measuring image quality. In a second step, we compare our experimental parameters with the ones of existing methods and show that a lot of the variability can directly be ascribed to these dierences in experimental methodology and choice of variables. In particular, the choice of a task, e.g., judging image quality vs. free viewing, has a great impact on measured saliency maps, suggesting that even for a mildly cognitive task, ground truth obtained by free viewing does not adapt well. Careful analysis of the prior art also reveals that systematic bias can occur depending on instrumental calibration and the choice of test images. We conclude this work by proposing a

  4. ATM Quality of Service Parameters at 45 Mbps Using a Satellite Emulator: Laboratory Measurements

    NASA Technical Reports Server (NTRS)

    Ivancic, William D.; Bobinsky, Eric A.

    1997-01-01

    Results of 45-Mbps DS3 intermediate-frequency loopback measurements of asynchronous transfer mode (ATM) quality of service parameters (cell error ratio and cell loss ratio) are presented. These tests, which were conducted at the NASA Lewis Research Center in support of satellite-ATM interoperability research, represent initial efforts to quantify the minimum parameters for stringent ATM applications, such as MPEG-1 and MPEG-2 video transmission. Portions of these results were originally presented to the International Telecommunications Union's ITU-R Working Party 4B in February 1996 in support of their Draft Preliminary Recommendation on the Transmission of ATM Traffic via Satellite.

  5. Quality of remote sensing measurements of cloud physical parameters in the cooperative convective precipitation experiment

    NASA Technical Reports Server (NTRS)

    Wu, M.-L.

    1985-01-01

    In order to develop the remote sensing techniques to infer cloud physical parameters, a multispectral cloud radiometer (MCR) was mounted on a NASA high-altitude aircraft in conjunction with the Cooperative Convective Precipitation Experiment in 1981. The MCR has seven spectral channels, of which three are centered near windows associated with water vapor bands in the near infrared, two are centered near the oxygen A band at 0.76 microns, one is centered at the 1.14-micron water vapor band, and one is centered in the thermal infrared. The reflectance and temperature measured on May 31, 1981, are presented together with theoretical calculations. The results indicate that the MCR produces quality measurements. Therefore several cloud parameters can be derived with good accuracy. The parameters are the cloud-scaled optical thickness, cloud top pressure, volume scattering coefficient, particle thermodynamic phase, effective mean particle size, and cloud-top temperature.

  6. A measurement-driven approach to assess power line telecommunication (PLT) network quality of service (QoS) performance parameters

    NASA Astrophysics Data System (ADS)

    Betta, G.; Capriglione, D.; Ferrigno, L.; Laracca, M.

    2009-10-01

    Power line telecommunication (PLT) technology offers cheap and fast ways for providing in-home broadband services and local area networking. Its main advantage is due to the possibility of using the pre-existing electrical grid as a communication channel. Nevertheless, technical challenges arise from the difficulty of operating on a hostile medium, not designed for communication purposes, characterized by complex channel modeling and by varying time response. These aspects put practical problems for designers and testers in the assessment of network quality of service performance parameters such as the throughput, the latency, the jitter, and the reliability. The measurement of these parameters has not yet been standardized so that there do not exist reference test set-ups and measurement methodologies (i.e. the type of isolation from the ac main, the observation time and the number of experiments, the measurement uncertainty and so on). Consequently, experiments executed by adopting different methods may lead to incompatible measurement results, thus making it also impossible to have reliable comparisons of different PLT modems. Really, the development of standard procedures is a very difficult task because the scenarios in which the PLT modems can work are very wide and then the application of an exhaustive approach (in which all the parameters influencing the PLT performance should be considered) would be very complex and time consuming, thus making the modem characterization very expensive. In this paper, the authors propose a methodological approach to develop an efficient measurement procedure able to reliably assess the performance of PLT modems (in terms of network quality of service parameters) with a minimum number of experiments. It is based on both creating a reconfigurable grid to which real disturbing loads are connected and implementing an original design of the experiment technique based on the effects of the uncertainty of the measurement results

  7. Evaluation of Measurements Collected with Multi-Parameter Continuous Water-Quality Monitors in Selected Illinois Streams, 2001-03

    USGS Publications Warehouse

    Groschen, George E.; King, Robin B.

    2005-01-01

    Eight streams, representing a wide range of environmental and water-quality conditions across Illinois, were monitored from July 2001 to October 2003 for five water-quality parameters as part of a pilot study by the U.S. Geological Survey (USGS) in cooperation with the Illinois Environmental Protection Agency (IEPA). Continuous recording multi-parameter water-quality monitors were installed to collect data on water temperature, dissolved-oxygen concentrations, specific conductivity, pH, and turbidity. The monitors were near USGS streamflow-gaging stations where stage and streamflow are continuously recorded. During the study period, the data collected for these five parameters generally met the data-quality objectives established by the USGS and IEPA at all eight stations. A similar pilot study during this period for measurement of chlorophyll concentrations failed to achieve the data-quality objectives. Of all the sensors used, the temperature sensors provided the most accurate and reliable measurements (generally within ?5 percent of a calibrated thermometer reading). Signal adjustments and calibration of all other sensors are dependent upon an accurate and precise temperature measurement. The dissolved-oxygen sensors were the next most reliable during the study and were responsive to changing conditions and accurate at all eight stations. Specific conductivity was the third most accurate and reliable measurement collected from the multi-parameter monitors. Specific conductivity at the eight stations varied widely-from less than 40 microsiemens (?S) at Rayse Creek near Waltonville to greater than 3,500 ?S at Salt Creek at Western Springs. In individual streams, specific conductivity often changed quickly (greater than 25 percent in less than 3 hours) and the sensors generally provided good to excellent record of these variations at all stations. The widest range of specific-conductivity measurements was in Salt Creek at Western Springs in the Greater Chicago

  8. Multi-parameter measurements using optical fibre long period gratings for indoor air quality monitoring

    NASA Astrophysics Data System (ADS)

    Hromadka, J.; Korposh, S.; Partridge, M. C.; James, S.; Davis, F.; Crump, D.; Lee, S.-W.; Tatam, R. P.

    2017-04-01

    An array of three long period gratings (LPGs) fabricated in a single optical fibre and multiplexed in the wavelength domain was used to measure simultaneously temperature, relative humidity (RH) and volatile organic compounds (VOCs). Each LPG sensor was designed to optimize its response to a desired measurand. The LPGs were fabricated with periods such that they operated at or near the phase matching turning point. The sensors were calibrated in the laboratory and the simultaneous measurement of the key indoor air quality parameters was undertaken in laboratory and office environments. It was demonstrated successfully that the data produced by the LPG sensor array under real conditions was in a good agreement with that produced by commercially available sensors. Further, the potential application of fibre optic sensors for VOCs detection at high levels has been demonstrated.

  9. Quality parameters of mango and potential of non-destructive techniques for their measurement - a review.

    PubMed

    Jha, S N; Narsaiah, K; Sharma, A D; Singh, M; Bansal, S; Kumar, R

    2010-01-01

    The king of fruits "Mango" (Mangifera indica L.) is very nutritious and rich in carotenes. India produces about 50% of the total world's mango. Many researchers have reported the maturity indices and quality parameters for determination of harvesting time and eating quality. The methods currently used for determination of quality of mango are mostly based on the biochemical analysis, which leads to destruction of the fruits. Numerous works are being carried out to explore some non-destructive methods such as Near Infrared (NIR), Nuclear Magnetic Resonance (NMR), X-ray and Computed Tomography (CT), electronic nose, machine vision and ultrasound for quality determination of fruits. This paper deals with some recent work reported on quality parameters, harvesting and post-harvest treatments in relation to quality of mango fruits and reviews on some of the potential non-destructive techniques that can be explored for quality determination of mango cultivars.

  10. Systems for monitoring and digitally recording water-quality parameters

    USGS Publications Warehouse

    Smoot, George F.; Blakey, James F.

    1966-01-01

    Digital recording of water-quality parameters is a link in the automated data collection and processing system of the U.S. Geological Survey. The monitoring and digital recording systems adopted by the Geological Survey, while punching all measurements on a standard paper tape, provide a choice of compatible components to construct a system to meet specific physical problems and data needs. As many as 10 parameters can be recorded by an Instrument, with the only limiting criterion being that measurements are expressed as electrical signals.

  11. Parameter-based estimation of CT dose index and image quality using an in-house android™-based software

    NASA Astrophysics Data System (ADS)

    Mubarok, S.; Lubis, L. E.; Pawiro, S. A.

    2016-03-01

    Compromise between radiation dose and image quality is essential in the use of CT imaging. CT dose index (CTDI) is currently the primary dosimetric formalisms in CT scan, while the low and high contrast resolutions are aspects indicating the image quality. This study was aimed to estimate CTDIvol and image quality measures through a range of exposure parameters variation. CTDI measurements were performed using PMMA (polymethyl methacrylate) phantom of 16 cm diameter, while the image quality test was conducted by using catphan ® 600. CTDI measurements were carried out according to IAEA TRS 457 protocol using axial scan mode, under varied parameters of tube voltage, collimation or slice thickness, and tube current. Image quality test was conducted accordingly under the same exposure parameters with CTDI measurements. An Android™ based software was also result of this study. The software was designed to estimate the value of CTDIvol with maximum difference compared to actual CTDIvol measurement of 8.97%. Image quality can also be estimated through CNR parameter with maximum difference to actual CNR measurement of 21.65%.

  12. Uncertainty analyses of the calibrated parameter values of a water quality model

    NASA Astrophysics Data System (ADS)

    Rode, M.; Suhr, U.; Lindenschmidt, K.-E.

    2003-04-01

    For river basin management water quality models are increasingly used for the analysis and evaluation of different management measures. However substantial uncertainties exist in parameter values depending on the available calibration data. In this paper an uncertainty analysis for a water quality model is presented, which considers the impact of available model calibration data and the variance of input variables. The investigation was conducted based on four extensive flowtime related longitudinal surveys in the River Elbe in the years 1996 to 1999 with varying discharges and seasonal conditions. For the model calculations the deterministic model QSIM of the BfG (Germany) was used. QSIM is a one dimensional water quality model and uses standard algorithms for hydrodynamics and phytoplankton dynamics in running waters, e.g. Michaelis Menten/Monod kinetics, which are used in a wide range of models. The multi-objective calibration of the model was carried out with the nonlinear parameter estimator PEST. The results show that for individual flow time related measuring surveys very good agreements between model calculation and measured values can be obtained. If these parameters are applied to deviating boundary conditions, substantial errors in model calculation can occur. These uncertainties can be decreased with an increased calibration database. More reliable model parameters can be identified, which supply reasonable results for broader boundary conditions. The extension of the application of the parameter set on a wider range of water quality conditions leads to a slight reduction of the model precision for the specific water quality situation. Moreover the investigations show that highly variable water quality variables like the algal biomass always allow a smaller forecast accuracy than variables with lower coefficients of variation like e.g. nitrate.

  13. Correlations among Stress Parameters, Meat and Carcass Quality Parameters in Pigs

    PubMed Central

    Dokmanovic, Marija; Baltic, Milan Z.; Duric, Jelena; Ivanovic, Jelena; Popovic, Ljuba; Todorovic, Milica; Markovic, Radmila; Pantic, Srdan

    2015-01-01

    Relationships among different stress parameters (lairage time and blood level of lactate and cortisol), meat quality parameters (initial and ultimate pH value, temperature, drip loss, sensory and instrumental colour, marbling) and carcass quality parameters (degree of rigor mortis and skin damages, hot carcass weight, carcass fat thickness, meatiness) were determined in pigs (n = 100) using Pearson correlations. After longer lairage, blood lactate (p<0.05) and degree of injuries (p<0.001) increased, meat became darker (p<0.001), while drip loss decreased (p<0.05). Higher lactate was associated with lower initial pH value (p<0.01), higher temperature (p<0.001) and skin blemishes score (p<0.05) and more developed rigor mortis (p<0.05), suggesting that lactate could be a predictor of both meat quality and the level of preslaughter stress. Cortisol affected carcass quality, so higher levels of cortisol were associated with increased hot carcass weight, carcass fat thickness on the back and at the sacrum and marbling, but also with decreased meatiness. The most important meat quality parameters (pH and temperature after 60 minutes) deteriorated when blood lactate concentration was above 12 mmol/L. PMID:25656214

  14. Cellular-enabled water quality measurements

    NASA Astrophysics Data System (ADS)

    Zhao, Y.; Kerkez, B.

    2013-12-01

    While the past decade has seen significant improvements in our ability to measure nutrients and other water quality parameters, the use of these sensors has yet to gain traction due to their costprohibitive nature and deployment expertise required on the part of researchers. Furthermore, an extra burden is incurred when real-time data access becomes an experimental requirement. We present an open-source hardware design to facilitate the real-time, low-cost, and robust measurements of water quality across large urbanized areas. Our hardware platform interfaces an embedded, vastly configurable, high-precision, ultra-low power measurement system, with a low-power cellular module. Each sensor station is configured with an IP address, permitting reliable streaming of sensor data to off-site locations as measurements are made. We discuss the role of high-quality hardware components during extreme event scenarios, and present preliminary performance metrics that validate the ability of the platform to provide streaming access to sensor measurements.

  15. Beef quality parameters estimation using ultrasound and color images

    PubMed Central

    2015-01-01

    Background Beef quality measurement is a complex task with high economic impact. There is high interest in obtaining an automatic quality parameters estimation in live cattle or post mortem. In this paper we set out to obtain beef quality estimates from the analysis of ultrasound (in vivo) and color images (post mortem), with the measurement of various parameters related to tenderness and amount of meat: rib eye area, percentage of intramuscular fat and backfat thickness or subcutaneous fat. Proposal An algorithm based on curve evolution is implemented to calculate the rib eye area. The backfat thickness is estimated from the profile of distances between two curves that limit the steak and the rib eye, previously detected. A model base in Support Vector Regression (SVR) is trained to estimate the intramuscular fat percentage. A series of features extracted on a region of interest, previously detected in both ultrasound and color images, were proposed. In all cases, a complete evaluation was performed with different databases including: color and ultrasound images acquired by a beef industry expert, intramuscular fat estimation obtained by an expert using a commercial software, and chemical analysis. Conclusions The proposed algorithms show good results to calculate the rib eye area and the backfat thickness measure and profile. They are also promising in predicting the percentage of intramuscular fat. PMID:25734452

  16. 40 CFR 141.87 - Monitoring requirements for water quality parameters.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... (c) Monitoring after installation of corrosion control. Any large system which installs optimal corrosion control treatment pursuant to § 141.81(d)(4) shall measure the water quality parameters at the...)(i). Any small or medium-size system which installs optimal corrosion control treatment shall conduct...

  17. 40 CFR 141.87 - Monitoring requirements for water quality parameters.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... (c) Monitoring after installation of corrosion control. Any large system which installs optimal corrosion control treatment pursuant to § 141.81(d)(4) shall measure the water quality parameters at the...)(i). Any small or medium-size system which installs optimal corrosion control treatment shall conduct...

  18. 40 CFR 141.87 - Monitoring requirements for water quality parameters.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... (c) Monitoring after installation of corrosion control. Any large system which installs optimal corrosion control treatment pursuant to § 141.81(d)(4) shall measure the water quality parameters at the...)(i). Any small or medium-size system which installs optimal corrosion control treatment shall conduct...

  19. 40 CFR 141.87 - Monitoring requirements for water quality parameters.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... (c) Monitoring after installation of corrosion control. Any large system which installs optimal corrosion control treatment pursuant to § 141.81(d)(4) shall measure the water quality parameters at the...)(i). Any small or medium-size system which installs optimal corrosion control treatment shall conduct...

  20. 40 CFR 141.87 - Monitoring requirements for water quality parameters.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... (c) Monitoring after installation of corrosion control. Any large system which installs optimal corrosion control treatment pursuant to § 141.81(d)(4) shall measure the water quality parameters at the...)(i). Any small or medium-size system which installs optimal corrosion control treatment shall conduct...

  1. Measuring health care process quality with software quality measures.

    PubMed

    Yildiz, Ozkan; Demirörs, Onur

    2012-01-01

    Existing quality models focus on some specific diseases, clinics or clinical areas. Although they contain structure, process, or output type measures, there is no model which measures quality of health care processes comprehensively. In addition, due to the not measured overall process quality, hospitals cannot compare quality of processes internally and externally. To bring a solution to above problems, a new model is developed from software quality measures. We have adopted the ISO/IEC 9126 software quality standard for health care processes. Then, JCIAS (Joint Commission International Accreditation Standards for Hospitals) measurable elements were added to model scope for unifying functional requirements. Assessment (diagnosing) process measurement results are provided in this paper. After the application, it was concluded that the model determines weak and strong aspects of the processes, gives a more detailed picture for the process quality, and provides quantifiable information to hospitals to compare their processes with multiple organizations.

  2. Quality assessment and artificial neural networks modeling for characterization of chemical and physical parameters of potable water.

    PubMed

    Salari, Marjan; Salami Shahid, Esmaeel; Afzali, Seied Hosein; Ehteshami, Majid; Conti, Gea Oliveri; Derakhshan, Zahra; Sheibani, Solmaz Nikbakht

    2018-04-22

    Today, due to the increase in the population, the growth of industry and the variety of chemical compounds, the quality of drinking water has decreased. Five important river water quality properties such as: dissolved oxygen (DO), total dissolved solids (TDS), total hardness (TH), alkalinity (ALK) and turbidity (TU) were estimated by parameters such as: electric conductivity (EC), temperature (T), and pH that could be measured easily with almost no costs. Simulate water quality parameters were examined with two methods of modeling include mathematical and Artificial Neural Networks (ANN). Mathematical methods are based on polynomial fitting with least square method and ANN modeling algorithms are feed-forward networks. All conditions/circumstances covered by neural network modeling were tested for all parameters in this study, except for Alkalinity. All optimum ANN models developed to simulate water quality parameters had precision value as R-value close to 0.99. The ANN model extended to simulate alkalinity with R-value equals to 0.82. Moreover, Surface fitting techniques were used to refine data sets. Presented models and equations are reliable/useable tools for studying water quality parameters at similar rivers, as a proper replacement for traditional water quality measuring equipment's. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Sequential injection system with multi-parameter analysis capability for water quality measurement.

    PubMed

    Kaewwonglom, Natcha; Jakmunee, Jaroon

    2015-11-01

    A simple sequential injection (SI) system with capability to determine multi-parameter has been developed for the determination of iron, manganese, phosphate and ammonium. A simple and compact colorimeter was fabricated in the laboratory to be employed as a detector. The system was optimized for suitable conditions for determining each parameter by changing software program and without reconfiguration of the hardware. Under the optimum conditions, the methods showed linear ranges of 0.2-10 mg L(-1) for iron and manganese determinations, and 0.3-5.0 mg L(-1) for phosphate and ammonium determinations, with correlation coefficients of 0.9998, 0.9973, 0.9987 and 0.9983, respectively. The system provided detection limits of 0.01, 0.14, 0.004 and 0.02 mg L(-1) for iron, manganese, phosphate and ammonium, respectively. The proposed system has good precision, low chemical consumption and high throughput. It was applied for monitoring water quality of Ping river in Chiang Mai, Thailand. Recoveries of the analysis were obtained in the range of 82-119%. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Composite measures of watershed health from a water quality perspective.

    PubMed

    Mallya, Ganeshchandra; Hantush, Mohamed; Govindaraju, Rao S

    2018-05-15

    Water quality data at gaging stations are typically compared with established federal, state, or local water quality standards to determine if violations (concentrations of specific constituents falling outside acceptable limits) have occurred. Based on the frequency and severity of water quality violations, risk metrics such as reliability, resilience, and vulnerability (R-R-V) are computed for assessing water quality-based watershed health. In this study, a modified methodology for computing R-R-V measures is presented, and a new composite watershed health index is proposed. Risk-based assessments for different water quality parameters are carried out using identified national sampling stations within the Upper Mississippi River Basin, the Maumee River Basin, and the Ohio River Basin. The distributional properties of risk measures with respect to water quality parameters are reported. Scaling behaviors of risk measures using stream order, specifically for the watershed health (WH) index, suggest that WH values increased with stream order for suspended sediment concentration, nitrogen, and orthophosphate in the Upper Mississippi River Basin. Spatial distribution of risk measures enable identification of locations exhibiting poor watershed health with respect to the chosen numerical standard, and the role of land use characteristics within the watershed. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Human voice quality measurement in noisy environments.

    PubMed

    Ueng, Shyh-Kuang; Luo, Cheng-Ming; Tsai, Tsung-Yu; Yeh, Hsuan-Chen

    2015-01-01

    Computerized acoustic voice measurement is essential for the diagnosis of vocal pathologies. Previous studies showed that ambient noises have significant influences on the accuracy of voice quality assessment. This paper presents a voice quality assessment system that can accurately measure qualities of voice signals, even though the input voice data are contaminated by low-frequency noises. The ambient noises in our living rooms and laboratories are collected and the frequencies of these noises are analyzed. Based on the analysis, a filter is designed to reduce noise level of the input voice signal. Then, improved numerical algorithms are employed to extract voice parameters from the voice signal to reveal the health of the voice signal. Compared with MDVP and Praat, the proposed method outperforms these two widely used programs in measuring fundamental frequency and harmonic-to-noise ratio, and its performance is comparable to these two famous programs in computing jitter and shimmer. The proposed voice quality assessment method is resistant to low-frequency noises and it can measure human voice quality in environments filled with noises from air-conditioners, ceiling fans and cooling fans of computers.

  6. Genetic parameters for meat quality traits of Australian lamb meat.

    PubMed

    Mortimer, S I; van der Werf, J H J; Jacob, R H; Hopkins, D L; Pannier, L; Pearce, K L; Gardner, G E; Warner, R D; Geesink, G H; Edwards, J E Hocking; Ponnampalam, E N; Ball, A J; Gilmour, A R; Pethick, D W

    2014-02-01

    Genetic parameters were estimated for a range of meat quality traits recorded on Australian lamb meat. Data were collected from Merino and crossbred progeny of Merino, terminal and maternal meat breed sires of the Information Nucleus programme. Lambs born between 2007 and 2010 (n=8968) were slaughtered, these being the progeny of 372 sires and 5309 dams. Meat quality traits were found generally to be of moderate heritability (estimates between 0.15 and 0.30 for measures of meat tenderness, meat colour, polyunsaturated fat content, mineral content and muscle oxidative capacity), with notable exceptions of intramuscular fat (0.48), ultimate pH (0.08) and fresh meat colour a* (0.08) and b* (0.10) values. Genetic correlations between hot carcass weight and the meat quality traits were low. The genetic correlation between intramuscular fat and shear force was high (-0.62). Several measures of meat quality (fresh meat redness, retail meat redness, retail oxy/met value and iron content) appear to have potential for inclusion in meat sheep breeding objectives. © 2013.

  7. The Modern Measurement Technology And Checking Of Shafs Parameters

    NASA Astrophysics Data System (ADS)

    Tichá, Šárka; Botek, Jan

    2015-12-01

    This paper is focused on rationalization checking parameters of shaft in companies engaged in the production of components of electric motors, wind turbines and vacuum systems. Customers increasing constantly their requirements to ensure the overall quality of the product, i.e. the quality of machining, dimensional and shape accuracy and overall purity of the subscribed products. The aim of this paper is to introduce using modern measurement technology in controlling these components and compare the results with existing control methodology. The main objective of this rationalization is to eliminate mistakes and shortcomings of current inspection methods.

  8. A Measure of Quality

    ERIC Educational Resources Information Center

    Environmental Science and Technology, 1976

    1976-01-01

    Recent national surveys conducted by the Council on Environmental Quality and others uncovered inconsistencies and confusion in the manner environmental quality parameters were used and reported. A standard air pollution index, comparative guide to water quality indicators and biological monitoring information are being developed. (BT)

  9. Outpatient management of oral vitamin K antagonist therapy: defining and measuring high-quality management.

    PubMed

    Phillips, Katherine W; Ansell, Jack

    2008-01-01

    Oral anticoagulation therapy with warfarin is the mainstay of prevention and treatment of thromboembolic disease. However, it remains one of the leading causes of harmful medication errors and medication-related adverse events. The beneficial outcomes of oral anticoagulation therapy are directly dependent upon the quality of dose and anticoagulation management, but the literature is not robust with regards to what constitutes such management. This review focuses on, and attempts to define, the parameters of high-quality anticoagulation management and identifies the appropriate outcome measures constituting high-quality management. Elements discussed include the most fundamental measure, time in therapeutic range, along with other parameters including therapy initiation, time to therapeutic range, dosing management when patients are not in therapeutic range, perioperative dosing management, patient education, and other important outcome measures. Healthcare providers who manage oral anticoagulation therapy should utilize these parameters as a measure of their performance in an effort to achieve high-quality anticoagulation management.

  10. Gaussian content as a laser beam quality parameter.

    PubMed

    Ruschin, Shlomo; Yaakobi, Elad; Shekel, Eyal

    2011-08-01

    We propose the Gaussian content (GC) as an optional quality parameter for the characterization of laser beams. It is defined as the overlap integral of a given field with an optimally defined Gaussian. The definition is especially suited for applications where coherence properties are targeted. Mathematical definitions and basic calculation procedures are given along with results for basic beam profiles. The coherent combination of an array of laser beams and the optimal coupling between a diode laser and a single-mode fiber are elaborated as application examples. The measurement of the GC and its conservation upon propagation are experimentally confirmed.

  11. [The measurement of data quality in censuses of population and housing].

    PubMed

    1980-01-01

    The determination of data quality in population and housing censuses is discussed. Principal types of errors commonly found in census data are reviewed, and the parameters used to evaluate data quality are described. Various methods for measuring data quality are outlined and possible applications of the methods are illustrated using Canadian examples

  12. Chemometric studies of water quality parameters of Sankarankovil block of Tirunelveli, Tamilnadu.

    PubMed

    Alagumuthu, G; Rajan, M

    2010-09-01

    The fluoride concentration in ground water was determined in Sankarankovil block of Tirunelveli district of Tamilnadu (India) where it is the only source of drinking water. Various other water quality parameters such as pH, electrical conductivity total hardness and total alkalinity as well as calcium, magnesium, carbonate, bicarbonate and chloride concentrations were also measured. A systematic calculation of correlation coefficient among different physico-chemical parameters was performed. The analytical results indicated considerable variations among the analyzed samples with respect to their chemical composition. Majority of the samples do not comply with Indian as well as WHO water quality standards. The fluoride concentration in the ground water of these villages varied from 0.66 to 3.84 mg l(-1), causes dental fluorosis among people especially children of these villages. The high and low fluoride containing areas were located using isopleth mapping technique. Overall water quality was found unsatisfactory for drinking purposes without any prior treatment except at few locations out of 50 villages.

  13. Development of wavelet-ANN models to predict water quality parameters in Hilo Bay, Pacific Ocean.

    PubMed

    Alizadeh, Mohamad Javad; Kavianpour, Mohamad Reza

    2015-09-15

    The main objective of this study is to apply artificial neural network (ANN) and wavelet-neural network (WNN) models for predicting a variety of ocean water quality parameters. In this regard, several water quality parameters in Hilo Bay, Pacific Ocean, are taken under consideration. Different combinations of water quality parameters are applied as input variables to predict daily values of salinity, temperature and DO as well as hourly values of DO. The results demonstrate that the WNN models are superior to the ANN models. Also, the hourly models developed for DO prediction outperform the daily models of DO. For the daily models, the most accurate model has R equal to 0.96, while for the hourly model it reaches up to 0.98. Overall, the results show the ability of the model to monitor the ocean parameters, in condition with missing data, or when regular measurement and monitoring are impossible. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. A potential hyperspectral remote sensing imager for water quality measurements

    NASA Astrophysics Data System (ADS)

    Zur, Yoav; Braun, Ofer; Stavitsky, David; Blasberger, Avigdor

    2003-04-01

    Utilization of Pan Chromatic and Multi Spectral Remote Sensing Imagery is wide spreading and becoming an established business for commercial suppliers of such imagery like ISI and others. Some emerging technologies are being used to generate Hyper-Spectral imagery (HSI) by aircraft as well as other platforms. The commercialization of such technology for Remote Sensing from space is still questionable and depends upon several parameters including maturity, cost, market reception and many others. HSI can be used in a variety of applications in agriculture, urban mapping, geology and others. One outstanding potential usage of HSI is for water quality monitoring, a subject studied in this paper. Water quality monitoring is becoming a major area of interest in HSI due to the increase in water demand around the globe. The ability to monitor water quality in real time having both spatial and temporal resolution is one of the advantages of Remote Sensing. This ability is not limited only for measurements of oceans and inland water, but can be applied for drinking and irrigation water reservoirs as well. HSI in the UV-VNIR has the ability to measure a wide range of constituents that define water quality. Among the constituents that can be measured are the pigment concentration of various algae, chlorophyll a and c, carotenoids and phycocyanin, thus enabling to define the algal phyla. Other parameters that can be measured are TSS (Total Suspended Solids), turbidity, BOD (Biological Oxygen Demand), hydrocarbons, oxygen demand. The study specifies the properties of such a space borne device that results from the spectral signatures and the absorption bands of the constituents in question. Other parameters considered are the repetition of measurements, the spatial aspects of the sensor and the SNR of the sensor in question.

  15. Verification of quality parameters for portal images in radiotherapy.

    PubMed

    Pesznyák, Csilla; Polgár, István; Weisz, Csaba; Király, Réka; Zaránd, Pál

    2011-03-01

    The purpose of the study was to verify different values of quality parameters of portal images in radiotherapy. We investigated image qualities of different field verification systems. Four EPIDs (Siemens OptiVue500aSi(®), Siemens BeamView Plus(®), Elekta iView(®) and Varian PortalVision™) were investigated with the PTW EPID QC PHANTOM(®) and compared with two portal film systems (Kodak X-OMAT(®) cassette with Kodak X-OMAT V(®) film and Kodak EC-L Lightweight(®) cassette with Kodak Portal Localisation ReadyPack(®) film). A comparison of the f50 and f25 values of the modulation transfer functions (MTFs) belonging to each of the systems revealed that the amorphous silicon EPIDs provided a slightly better high contrast resolution than the Kodak Portal Localisation ReadyPack(®) film with the EC-L Lightweight(®) cassette. The Kodak X-OMAT V(®) film gave a poor low contrast resolution: from the existing 27 holes only 9 were detectable. On the base of physical characteristics, measured in this work, the authors suggest the use of amorphous-silicon EPIDs producing the best image quality. Parameters of the EPIDs with scanning liquid ionisation chamber (SLIC) were very stable. The disadvantage of older versions of EPIDs like SLIC and VEPID is a poor DICOM implementation, and the modulation transfer function (MTF) values (f50 and f25) are less than that of aSi detectors.

  16. Measuring, evaluating and improving hospital quality parameters/dimensions--an integrated healthcare quality approach.

    PubMed

    Zineldin, Mosad; Camgöz-Akdağ, Hatice; Vasicheva, Valiantsina

    2011-01-01

    This paper aims to examine the major factors affecting cumulative summation, to empirically examine the major factors affecting satisfaction and to address the question whether patients in Kazakhstan evaluate healthcare similarly or differently from patients in Egypt and Jordan. A questionnaire, adapted from previous research, was distributed to Kazakhstan inpatients. The questionnaire contained 39 attributes about five newly-developed quality dimensions (5Qs), which were identified to be the most relevant attributes for hospitals. The questionnaire was translated into Russian to increase the response rate and improve data quality. Almost 200 usable questionnaires were returned. Frequency distribution, factor analysis and reliability checks were used to analyze the data. The three biggest concerns for Kazakhstan patients are: infrastructure; atmosphere; and interaction. Hospital staffs concern for patients' needs, parking facilities for visitors, waiting time and food temperature were all common specific attributes, which were perceived as concerns. These were shortcomings in all three countries. Improving health service quality by applying total relationship management and the 5Qs model together with a customer-orientation strategy is recommended. Results can be used by hospital staff to reengineer and redesign creatively their quality management processes and help move towards more effective healthcare quality strategies. Patients in three countries have similar concerns and quality perceptions. The paper describes a new instrument and method. The study assures relevance, validity and reliability, while being explicitly change-oriented. The authors argue that patient satisfaction is a cumulative construct, summing satisfaction as five different qualities (5Qs): object; processes; infrastructure; interaction and atmosphere.

  17. Prediction of Water Quality Parameters Using Statistical Methods: A Case Study in a Specially Protected Area, Ankara, Turkey

    NASA Astrophysics Data System (ADS)

    Alp, E.; Yücel, Ö.; Özcan, Z.

    2014-12-01

    Turkey has been making many legal arrangements for sustainable water management during the harmonization process with the European Union. In order to make cost effective and efficient decisions, monitoring network in Turkey has been expanding. However, due to time and budget constraints, desired number of monitoring campaigns can not be carried. Hence, in this study, independent parameters that can be measured easily and quickly are used to estimate water quality parameters in Lake Mogan and Eymir using linear regression. Nonpoint sources are one of the major pollutant components in Eymir and Mogan lakes. In this paper, a correlation between easily measurable parameters, DO, temperature, electrical conductivity, pH, precipitation and dependent variables, TN, TP, COD, Chl-a, TSS, Total Coliform is investigated. Simple regression analysis is performed for each season in Eymir and Mogan lakes by using SPSS Statistical program using the water quality data collected between 2006-2012. Regression analysis demonstrated significant linear relationship between measured and simulated concentrations for TN (R2=0.86), TP (R2=0.85), TSS (R2=0.91), Chl-a (R2=0.94), COD (R2=0.99), T. Coliform (R2=0.97) which are the best results in each season for Eymir and Mogan Lakes. The overall results of this study shows that by using easily measurable parameters even in ungauged situation the water quality of lakes can be predicted. Moreover, the outputs obtained from the regression equations can be used as an input for water quality models such as phosphorus budget model which is used to calculate the required reduction in the external phosphorus load to Lake Mogan to meet the water quality standards.

  18. Assessment and modeling of the groundwater hydrogeochemical quality parameters via geostatistical approaches

    NASA Astrophysics Data System (ADS)

    Karami, Shawgar; Madani, Hassan; Katibeh, Homayoon; Fatehi Marj, Ahmad

    2018-03-01

    Geostatistical methods are one of the advanced techniques used for interpolation of groundwater quality data. The results obtained from geostatistics will be useful for decision makers to adopt suitable remedial measures to protect the quality of groundwater sources. Data used in this study were collected from 78 wells in Varamin plain aquifer located in southeast of Tehran, Iran, in 2013. Ordinary kriging method was used in this study to evaluate groundwater quality parameters. According to what has been mentioned in this paper, seven main quality parameters (i.e. total dissolved solids (TDS), sodium adsorption ratio (SAR), electrical conductivity (EC), sodium (Na+), total hardness (TH), chloride (Cl-) and sulfate (SO4 2-)), have been analyzed and interpreted by statistical and geostatistical methods. After data normalization by Nscore method in WinGslib software, variography as a geostatistical tool to define spatial regression was compiled and experimental variograms were plotted by GS+ software. Then, the best theoretical model was fitted to each variogram based on the minimum RSS. Cross validation method was used to determine the accuracy of the estimated data. Eventually, estimation maps of groundwater quality were prepared in WinGslib software and estimation variance map and estimation error map were presented to evaluate the quality of estimation in each estimated point. Results showed that kriging method is more accurate than the traditional interpolation methods.

  19. Venous Thromboembolism Quality Measures Fail to Accurately Measure Quality.

    PubMed

    Lau, Brandyn D; Streiff, Michael B; Pronovost, Peter J; Haut, Elliott R

    2018-03-20

    Venous thromboembolism (VTE) is 1 of the most common causes of preventable harm for patients in hospitals. Consequently, the Joint Commission, the Centers for Medicare and Medicaid Services, the Agency for Healthcare Research and Quality, the United Kingdom Care Quality Commission, the Australian Commission on Safety and Quality in Health Care, the Maryland Health Services Cost Review Commission, and the American College of Surgeons have prioritized measuring and reporting VTE outcomes with the goal of reducing the incidence of and preventable harm from VTE. We developed a rubric for defect-free VTE prevention, graded each organizational VTE quality measure, and found that none of the current VTE-related quality measures adequately characterizes VTE prevention efforts or outcomes in hospitalized patients. Effective VTE prevention is multifactorial: clinicians must assess patients' risk for VTE and prescribe therapy appropriate for each patient's risk profile, patients must accept the prescribed therapy, and nurses must administer the therapy as prescribed. First, an ideal, defect-free VTE prevention process measure requires: (1) documentation of a standardized VTE risk assessment; (2) prescription of optimal, risk-appropriate VTE prophylaxis; and (3) administration of all risk-appropriate VTE prophylaxis as prescribed. Second, an ideal VTE outcome measure should define potentially preventable VTE as VTE that developed in patients who experienced any VTE prevention process failures. © 2018 American Heart Association, Inc.

  20. [The design and experiment of multi-parameter water quality monitoring microsystem based on MOEMS microspectrometer].

    PubMed

    Wei, Kang-Lin; Wen, Zhi-Yu; Guo, Jian; Chen, Song-Bo

    2012-07-01

    Aiming at the monitoring and protecting of water resource environment, a multi-parameter water quality monitoring microsystem based on microspectrometer was put forward in the present paper. The microsystem is mainly composed of MOEMS microspectrometer, flow paths system and embedded measuring & controlling system. It has the functions of self-injecting samples and detection regents, automatic constant temperature, self -stirring, self- cleaning and samples' spectrum detection. The principle prototype machine of the microsystem was developed, and its structure principle was introduced in the paper. Through experiment research, it was proved that the principle prototype machine can rapidly detect quite a few water quality parameters and can meet the demands of on-line water quality monitoring, moreover, the principle prototype machine has strong function expansibility.

  1. Measuring Rural Hospital Quality

    ERIC Educational Resources Information Center

    Moscovice, Ira; Wholey, Douglas R.; Klingner, Jill; Knott, Astrid

    2004-01-01

    Increased interest in the measurement of hospital quality has been stimulated by accrediting bodies, purchaser coalitions, government agencies, and other entities. This paper examines quality measurement for hospitals in rural settings. We seek to identify rural hospital quality measures that reflect quality in all hospitals and that are sensitive…

  2. Parameters and Measures in Assessment of Motor Learning in Neurorehabilitation; A Systematic Review of the Literature

    PubMed Central

    Shishov, Nataliya; Melzer, Itshak; Bar-Haim, Simona

    2017-01-01

    Upper limb function, essential for daily life, is often impaired in individuals after stroke and cerebral palsy (CP). For an improved upper limb function, learning should occur, and therefore training with motor learning principles is included in many rehabilitation interventions. Despite accurate measurement being an important aspect for examination and optimization of treatment outcomes, there are no standard algorithms for outcome measures selection. Moreover, the ability of the chosen measures to identify learning is not well established. We aimed to review and categorize the parameters and measures utilized for identification of motor learning in stroke and CP populations. PubMed, Pedro, and Web of Science databases were systematically searched between January 2000 and March 2016 for studies assessing a form of motor learning following upper extremity training using motor control measures. Thirty-two studies in persons after stroke and 10 studies in CP of any methodological quality were included. Identified outcome measures were sorted into two categories, “parameters,” defined as identifying a form of learning, and “measures,” as tools measuring the parameter. Review's results were organized as a narrative synthesis focusing on the outcome measures. The included studies were heterogeneous in their study designs, parameters and measures. Parameters included adaptation (n = 6), anticipatory control (n = 2), after-effects (n = 3), de-adaptation (n = 4), performance (n = 24), acquisition (n = 8), retention (n = 8), and transfer (n = 14). Despite motor learning theory's emphasis on long-lasting changes and generalization, the majority of studies did not assess the retention and transfer parameters. Underlying measures included kinematic analyses in terms of speed, geometry or both (n = 39), dynamic metrics, measures of accuracy, consistency, and coordination. There is no exclusivity of measures to a specific parameter. Many factors affect task performance

  3. Distribution of water quality parameters in Dhemaji district, Assam (India).

    PubMed

    Buragohain, Mridul; Bhuyan, Bhabajit; Sarma, H P

    2010-07-01

    The primary objective of this study is to present a statistically significant water quality database of Dhemaji district, Assam (India) with special reference to pH, fluoride, nitrate, arsenic, iron, sodium and potassium. 25 water samples collected from different locations of five development blocks in Dhemaji district have been studied separately. The implications presented are based on statistical analyses of the raw data. Normal distribution statistics and reliability analysis (correlation and covariance matrix) have been employed to find out the distribution pattern, localisation of data, and other related information. Statistical observations show that all the parameters under investigation exhibit non uniform distribution with a long asymmetric tail either on the right or left side of the median. The width of the third quartile was consistently found to be more than the second quartile for each parameter. Differences among mean, mode and median, significant skewness and kurtosis value indicate that the distribution of various water quality parameters in the study area is widely off normal. Thus, the intrinsic water quality is not encouraging due to unsymmetrical distribution of various water quality parameters in the study area.

  4. Quality Parameters of Six Cultivars of Blueberry Using Computer Vision

    PubMed Central

    Celis Cofré, Daniela; Silva, Patricia; Enrione, Javier; Osorio, Fernando

    2013-01-01

    Background. Blueberries are considered an important source of health benefits. This work studied six blueberry cultivars: “Duke,” “Brigitta”, “Elliott”, “Centurion”, “Star,” and “Jewel”, measuring quality parameters such as °Brix, pH, moisture content using standard techniques and shape, color, and fungal presence obtained by computer vision. The storage conditions were time (0–21 days), temperature (4 and 15°C), and relative humidity (75 and 90%). Results. Significant differences (P < 0.05) were detected between fresh cultivars in pH, °Brix, shape, and color. However, the main parameters which changed depending on storage conditions, increasing at higher temperature, were color (from blue to red) and fungal presence (from 0 to 15%), both detected using computer vision, which is important to determine a shelf life of 14 days for all cultivars. Similar behavior during storage was obtained for all cultivars. Conclusion. Computer vision proved to be a reliable and simple method to objectively determine blueberry decay during storage that can be used as an alternative approach to currently used subjective measurements. PMID:26904598

  5. The multi-parameter remote measurement of rainfall

    NASA Technical Reports Server (NTRS)

    Atlas, D.; Ulbrich, C. W.; Meneghini, R.

    1982-01-01

    The measurement of rainfall by remote sensors is investigated. One parameter radar rainfall measurement is limited because both reflectivity and rain rate are dependent on at least two parameters of the drop size distribution (DSD), i.e., representative raindrop size and number concentration. A generalized rain parameter diagram is developed which includes a third distribution parameter, the breadth of the DSD, to better specify rain rate and all possible remote variables. Simulations show the improvement in accuracy attainable through the use of combinations of two and three remote measurables. The spectrum of remote measurables is reviewed. These include path integrated techniques of radiometry and of microwave and optical attenuation.

  6. A Comprehensive Review on Water Quality Parameters Estimation Using Remote Sensing Techniques.

    PubMed

    Gholizadeh, Mohammad Haji; Melesse, Assefa M; Reddi, Lakshmi

    2016-08-16

    Remotely sensed data can reinforce the abilities of water resources researchers and decision makers to monitor waterbodies more effectively. Remote sensing techniques have been widely used to measure the qualitative parameters of waterbodies (i.e., suspended sediments, colored dissolved organic matter (CDOM), chlorophyll-a, and pollutants). A large number of different sensors on board various satellites and other platforms, such as airplanes, are currently used to measure the amount of radiation at different wavelengths reflected from the water's surface. In this review paper, various properties (spectral, spatial and temporal, etc.) of the more commonly employed spaceborne and airborne sensors are tabulated to be used as a sensor selection guide. Furthermore, this paper investigates the commonly used approaches and sensors employed in evaluating and quantifying the eleven water quality parameters. The parameters include: chlorophyll-a (chl-a), colored dissolved organic matters (CDOM), Secchi disk depth (SDD), turbidity, total suspended sediments (TSS), water temperature (WT), total phosphorus (TP), sea surface salinity (SSS), dissolved oxygen (DO), biochemical oxygen demand (BOD) and chemical oxygen demand (COD).

  7. A Comprehensive Review on Water Quality Parameters Estimation Using Remote Sensing Techniques

    PubMed Central

    Gholizadeh, Mohammad Haji; Melesse, Assefa M.; Reddi, Lakshmi

    2016-01-01

    Remotely sensed data can reinforce the abilities of water resources researchers and decision makers to monitor waterbodies more effectively. Remote sensing techniques have been widely used to measure the qualitative parameters of waterbodies (i.e., suspended sediments, colored dissolved organic matter (CDOM), chlorophyll-a, and pollutants). A large number of different sensors on board various satellites and other platforms, such as airplanes, are currently used to measure the amount of radiation at different wavelengths reflected from the water’s surface. In this review paper, various properties (spectral, spatial and temporal, etc.) of the more commonly employed spaceborne and airborne sensors are tabulated to be used as a sensor selection guide. Furthermore, this paper investigates the commonly used approaches and sensors employed in evaluating and quantifying the eleven water quality parameters. The parameters include: chlorophyll-a (chl-a), colored dissolved organic matters (CDOM), Secchi disk depth (SDD), turbidity, total suspended sediments (TSS), water temperature (WT), total phosphorus (TP), sea surface salinity (SSS), dissolved oxygen (DO), biochemical oxygen demand (BOD) and chemical oxygen demand (COD). PMID:27537896

  8. Downhole steam quality measurement

    DOEpatents

    Lee, D.O.; Montoya, P.C.; Muir, J.F.; Wayland, J.R. Jr.

    1985-06-19

    The present invention relates to an empirical electrical method for remote sensing of steam quality utilizing flow-through grids which allow measurement of the electrical properties of a flowing two-phase mixture. The measurement of steam quality in the oil field is important to the efficient application of steam assisted recovery of oil. Because of the increased energy content in higher quality steam it is important to maintain the highest possible steam quality at the injection sandface. The effectiveness of a steaming operation without a measure of steam quality downhole close to the point of injection would be difficult to determine. Therefore, a need exists for the remote sensing of steam quality.

  9. Redefining Quality Measurement in Cancer Care.

    PubMed

    Nardi, Elizabeth A; McCanney, James; Winckworth-Prejsnar, Katy; Schatz, Alyssa A; Adelson, Kerin; Neubauer, Marcus; Smith, Mary Lou; Walters, Ronald; Carlson, Robert W

    2018-05-01

    Quality measurement in oncology is increasing in significance as payment schemes shift from volume to value. As demand for quality measures increases, challenges in the development of quality measures, standardization across measures, and the limitations of health information technology have become apparent. Moreover, the time and financial burden associated with developing, tracking, and reporting quality measures are substantial. Despite these challenges, best practices and leaders in the field of quality measurement in oncology have emerged. To understand the current challenges and promising practices in quality measurement and to explore future considerations for measure development and measure reporting in oncology, NCCN convened the NCCN Policy Summit: Redefining Quality Measurement in Oncology. The summit included discussion of the current quality landscape and efforts to develop quality measures, use of quality measures in various programs, patient perspective of quality, and challenges and best practices for quality reporting. Copyright © 2018 by the National Comprehensive Cancer Network.

  10. Measuring UV Curing Parameters of Commercial Photopolymers used in Additive Manufacturing.

    PubMed

    Bennett, Joe

    2017-12-01

    A testing methodology was developed to expose photopolymer resins and measure the cured material to determine two key parameters related to the photopolymerization process: E c (critical energy to initiate polymerization) and D p (penetration depth of curing light). Five commercially available resins were evaluated under exposure from 365 nm and 405 nm light at varying power densities and energies. Three different methods for determining the thickness of the cured resin were evaluated. Caliper measurements, stylus profilometry, and confocal laser scanning microscopy showed similar results for hard materials while caliper measurement of a soft, elastomeric material proved inaccurate. Working curves for the five photopolymers showed unique behavior both within and among the resins as a function of curing light wavelength. E c and D p for the five resins showed variations as large as 10×. Variations of this magnitude, if unknown to the user and not controlled for, will clearly affect printed part quality. This points to the need for a standardized approach for determining and disseminating these, and perhaps, other key parameters.

  11. WATGIS: A GIS-Based Lumped Parameter Water Quality Model

    Treesearch

    Glenn P. Fernandez; George M. Chescheir; R. Wayne Skaggs; Devendra M. Amatya

    2002-01-01

    A Geographic Information System (GIS)­based, lumped parameter water quality model was developed to estimate the spatial and temporal nitrogen­loading patterns for lower coastal plain watersheds in eastern North Carolina. The model uses a spatially distributed delivery ratio (DR) parameter to account for nitrogen retention or loss along a drainage network. Delivery...

  12. Scale Control and Quality Management of Printed Image Parameters

    NASA Astrophysics Data System (ADS)

    Novoselskaya, O. A.; Kolesnikov, V. L.; Solov'eva, T. V.; Nagornova, I. V.; Babluyk, E. B.; Trapeznikova, O. V.

    2017-06-01

    The article provides a comparison of the main valuation techniques for a regulated parameter of printability of the offset paper by current standards GOST 24356 and ISO 3783: 2006. The results of development and implementation of a complex test scale for management and control the quality of printed production are represented. The estimation scale is introduced. It includes normalized parameters of print optical density, print uniformity, picking out speed, the value of dot gain, print contrast with the added criteria of minimizing microtexts, a paper slip, resolution threshold and effusing ability of paper surface. The results of analysis allow directionally form surface properties of the substrate to facilitate achieving the required quality of the printed image parameters, i. e. optical density of a print at a predetermined level not less than 1.3, the print uniformity with minimal deviation of dot gain about the order of 10 per cents.

  13. Application of the acoustic voice quality index for objective measurement of dysphonia severity.

    PubMed

    Núñez-Batalla, Faustino; Díaz-Fresno, Estefanía; Álvarez-Fernández, Andrea; Muñoz Cordero, Gabriela; Llorente Pendás, José Luis

    Over the past several decades, many acoustic parameters have been studied as sensitive to and to measure dysphonia. However, current acoustic measures might not be sensitive measures of perceived voice quality. A meta-analysis which evaluated the relationship between perceived overall voice quality and several acoustic-phonetic correlates, identified measures that do not rely on the extraction of the fundamental period, such the measures derived from the cepstrum, and that can be used in sustained vowel as well as continuous speech samples. A specific and recently developed method to quantify the severity of overall dysphonia is the acoustic voice quality index (AVQI) that is a multivariate construct that combines multiple acoustic markers to yield a single number that correlates reasonably with overall vocal quality. This research is based on one pool of voice recordings collected in two sets of subjects: 60 vocally normal and 58 voice disordered participants. A sustained vowel and a sample of connected speech were recorded and analyzed to obtain the six parameters included in the AVQI using the program Praat. Statistical analysis was completed using SPSS for Windows, version 12.0. Correlation between perception of overall voice quality and AVQI: A significant difference exists (t(95) = 9.5; p<.000) between normal and dysphonic voices. The findings of this study demonstrate the clinical feasibility of the AVQI as a measure of dysphonia severity. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.

  14. Effects of process parameters on the molding quality of the micro-needle array

    NASA Astrophysics Data System (ADS)

    Qiu, Z. J.; Ma, Z.; Gao, S.

    2016-07-01

    Micro-needle array, which is used in medical applications, is a kind of typical injection molded products with microstructures. Due to its tiny micro-features size and high aspect ratios, it is more likely to produce short shots defects, leading to poor molding quality. The injection molding process of the micro-needle array was studied in this paper to find the effects of the process parameters on the molding quality of the micro-needle array and to provide theoretical guidance for practical production of high-quality products. With the shrinkage ratio and warpage of micro needles as the evaluation indices of the molding quality, the orthogonal experiment was conducted and the analysis of variance was carried out. According to the results, the contribution rates were calculated to determine the influence of various process parameters on molding quality. The single parameter method was used to analyse the main process parameter. It was found that the contribution rate of the holding pressure on shrinkage ratio and warpage reached 83.55% and 94.71% respectively, far higher than that of the other parameters. The study revealed that the holding pressure is the main factor which affects the molding quality of micro-needle array so that it should be focused on in order to obtain plastic parts with high quality in the practical production.

  15. Prediction of HDR quality by combining perceptually transformed display measurements with machine learning

    NASA Astrophysics Data System (ADS)

    Choudhury, Anustup; Farrell, Suzanne; Atkins, Robin; Daly, Scott

    2017-09-01

    We present an approach to predict overall HDR display quality as a function of key HDR display parameters. We first performed subjective experiments on a high quality HDR display that explored five key HDR display parameters: maximum luminance, minimum luminance, color gamut, bit-depth and local contrast. Subjects rated overall quality for different combinations of these display parameters. We explored two models | a physical model solely based on physically measured display characteristics and a perceptual model that transforms physical parameters using human vision system models. For the perceptual model, we use a family of metrics based on a recently published color volume model (ICT-CP), which consists of the PQ luminance non-linearity (ST2084) and LMS-based opponent color, as well as an estimate of the display point spread function. To predict overall visual quality, we apply linear regression and machine learning techniques such as Multilayer Perceptron, RBF and SVM networks. We use RMSE and Pearson/Spearman correlation coefficients to quantify performance. We found that the perceptual model is better at predicting subjective quality than the physical model and that SVM is better at prediction than linear regression. The significance and contribution of each display parameter was investigated. In addition, we found that combined parameters such as contrast do not improve prediction. Traditional perceptual models were also evaluated and we found that models based on the PQ non-linearity performed better.

  16. Downhole steam quality measurement

    DOEpatents

    Lee, David O.; Montoya, Paul C.; Muir, James F.; Wayland, Jr., J. Robert

    1987-01-01

    An empirical method for the remote sensing of steam quality that can be easily adapted to downhole steam quality measurements by measuring the electrical properties of two-phase flow across electrode grids at low frequencies.

  17. Performance of biometric quality measures.

    PubMed

    Grother, Patrick; Tabassi, Elham

    2007-04-01

    We document methods for the quantitative evaluation of systems that produce a scalar summary of a biometric sample's quality. We are motivated by a need to test claims that quality measures are predictive of matching performance. We regard a quality measurement algorithm as a black box that converts an input sample to an output scalar. We evaluate it by quantifying the association between those values and observed matching results. We advance detection error trade-off and error versus reject characteristics as metrics for the comparative evaluation of sample quality measurement algorithms. We proceed this with a definition of sample quality, a description of the operational use of quality measures. We emphasize the performance goal by including a procedure for annotating the samples of a reference corpus with quality values derived from empirical recognition scores.

  18. Retrieval of Aerosol Parameters from Continuous H24 Lidar-Ceilometer Measurements

    NASA Astrophysics Data System (ADS)

    Dionisi, D.; Barnaba, F.; Costabile, F.; Di Liberto, L.; Gobbi, G. P.; Wille, H.

    2016-06-01

    Ceilometer technology is increasingly applied to the monitoring and the characterization of tropospheric aerosols. In this work, a method to estimate some key aerosol parameters (extinction coefficient, surface area concentration and volume concentration) from ceilometer measurements is presented. A numerical model has been set up to derive a mean functional relationships between backscatter and the above mentioned parameters based on a large set of simulated aerosol optical properties. A good agreement was found between the modeled backscatter and extinction coefficients and the ones measured by the EARLINET Raman lidars. The developed methodology has then been applied to the measurements acquired by a prototype Polarization Lidar-Ceilometer (PLC). This PLC instrument was developed within the EC- LIFE+ project "DIAPASON" as an upgrade of the commercial, single-channel Jenoptik CHM15k system. The PLC run continuously (h24) close to Rome (Italy) for a whole year (2013-2014). Retrievals of the aerosol backscatter coefficient at 1064 nm and of the relevant aerosol properties were performed using the proposed methodology. This information, coupled to some key aerosol type identification made possible by the depolarization channel, allowed a year-round characterization of the aerosol field at this site. Examples are given to show how this technology coupled to appropriate data inversion methods is potentially useful in the operational monitoring of parameters of air quality and meteorological interest.

  19. Material parameter measurements at high temperatures

    NASA Technical Reports Server (NTRS)

    Dominek, A.; Park, A.; Peters, L., Jr.

    1988-01-01

    Alternate fixtures of techniques for the measurement of the constitutive material parameters at elevated temperatures are presented. The technique utilizes scattered field data from material coated cylinders between parallel plates or material coated hemispheres over a finite size groundplane. The data acquisition is centered around the HP 8510B Network Analyzer. The parameters are then found from a numerical search algorithm using the Newton-Ralphson technique with the measured and calculated fields from these canonical scatters. Numerical and experimental results are shown.

  20. Quality measurement in diabetes care.

    PubMed

    Leas, Brian F; Berman, Bettina; Kash, Kathryn M; Crawford, Albert G; Toner, Richard W; Goldfarb, Neil I; Nash, David B

    2009-10-01

    This study aimed to evaluate diabetes quality measurement efforts, assess their strengths and areas for improvement, and identify gaps not adequately addressed by these measures. We conducted an environmental scan of diabetes quality measures, focusing on metrics included in the National Quality Measures Clearinghouse or promulgated by leading measurement organizations. Key informant interviews were also completed with thought leaders who develop, promote, and use quality measures. The environmental scan identified 146 distinct measures spanning 31 clinical processes or outcomes. This suggests a measurement system that is both redundant and inconsistent, with many different measures assessing the same clinical indicators. Interviewees believe that current diabetes measurement efforts are excessively broad and complex and expressed a need for better harmonization of these measures. Several gaps were also found, including a lack of measures focusing on population health, structural elements of health care, and prevention of diabetes.

  1. Coherence parameter measurements for neon and hydrogen

    NASA Astrophysics Data System (ADS)

    Wright, Robert; Hargreaves, Leigh; Khakoo, Murtadha; Zatsarinny, Oleg; Bartschat, Klaus; Stauffer, Al

    2015-09-01

    We present recent coherence parameter measurements for excitation of neon and hydrogen by 50 eV electrons. The measurements were made using a crossed electron/gas beam spectrometer, featuring a hemispherically selected electron energy analyzer for detecting scattered electrons and double-reflection VUV polarization analyzer to register fluorescence photons. Time-coincidence counting methods on the electron and photon signals were employed to determine Stokes Parameters at each scattering angle, with data measured at angles between 20 - 115 degrees. The data are compared with calculated results using the B-Spline R-Matrix (BSR) and Relativistic Distorted Wave (RDW) approaches. Measurements were made of both the linear (Plin and γ) and circular (Lperp) parameters for the lowest lying excited states in these two targets. We particularly focus on results in the Lperp parameter, which shows unusual behavior in these particular targets, including strong sign changes implying reversal of the angular momentum transfer. In the case of neon, the unusual behavior is well captured by the BSR, but not by other models.

  2. A proteomics performance standard to support measurement quality in proteomics.

    PubMed

    Beasley-Green, Ashley; Bunk, David; Rudnick, Paul; Kilpatrick, Lisa; Phinney, Karen

    2012-04-01

    The emergence of MS-based proteomic platforms as a prominent technology utilized in biochemical and biomedical research has increased the need for high-quality MS measurements. To address this need, National Institute of Standards and Technology (NIST) reference material (RM) 8323 yeast protein extract is introduced as a proteomics quality control material for benchmarking the preanalytical and analytical performance of proteomics-based experimental workflows. RM 8323 yeast protein extract is based upon the well-characterized eukaryote Saccharomyces cerevisiae and can be utilized in the design and optimization of proteomics-based methodologies from sample preparation to data analysis. To demonstrate its utility as a proteomics quality control material, we coupled LC-MS/MS measurements of RM 8323 with the NIST MS Quality Control (MSQC) performance metrics to quantitatively assess the LC-MS/MS instrumentation parameters that influence measurement accuracy, repeatability, and reproducibility. Due to the complexity of the yeast proteome, we also demonstrate how NIST RM 8323, along with the NIST MSQC performance metrics, can be used in the evaluation and optimization of proteomics-based sample preparation methods. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Experiments for practical education in process parameter optimization for selective laser sintering to increase workpiece quality

    NASA Astrophysics Data System (ADS)

    Reutterer, Bernd; Traxler, Lukas; Bayer, Natascha; Drauschke, Andreas

    2016-04-01

    Selective Laser Sintering (SLS) is considered as one of the most important additive manufacturing processes due to component stability and its broad range of usable materials. However the influence of the different process parameters on mechanical workpiece properties is still poorly studied, leading to the fact that further optimization is necessary to increase workpiece quality. In order to investigate the impact of various process parameters, laboratory experiments are implemented to improve the understanding of the SLS limitations and advantages on an educational level. Experiments are based on two different workstations, used to teach students the fundamentals of SLS. First of all a 50 W CO2 laser workstation is used to investigate the interaction of the laser beam with the used material in accordance with varied process parameters to analyze a single-layered test piece. Second of all the FORMIGA P110 laser sintering system from EOS is used to print different 3D test pieces in dependence on various process parameters. Finally quality attributes are tested including warpage, dimension accuracy or tensile strength. For dimension measurements and evaluation of the surface structure a telecentric lens in combination with a camera is used. A tensile test machine allows testing of the tensile strength and the interpreting of stress-strain curves. The developed laboratory experiments are suitable to teach students the influence of processing parameters. In this context they will be able to optimize the input parameters depending on the component which has to be manufactured and to increase the overall quality of the final workpiece.

  4. Measuring quality in anatomic pathology.

    PubMed

    Raab, Stephen S; Grzybicki, Dana Marie

    2008-06-01

    This article focuses mainly on diagnostic accuracy in measuring quality in anatomic pathology, noting that measuring any quality metric is complex and demanding. The authors discuss standardization and its variability within and across areas of care delivery and efforts involving defining and measuring error to achieve pathology quality and patient safety. They propose that data linking error to patient outcome are critical for developing quality improvement initiatives targeting errors that cause patient harm in addition to using methods of root cause analysis, beyond those traditionally used in cytologic-histologic correlation, to assist in the development of error reduction and quality improvement plans.

  5. Fieldwork measurement of indoor environmental quality (IEQ) in Malaysian platinum-rated green office buildings

    NASA Astrophysics Data System (ADS)

    Tharim, Asniza Hamimi Abdul; Samad, Muna Hanim Abdul; Ismail, Mazran

    2017-10-01

    An Indoor Environmental Quality (IEQ) fieldwork assessment was conducted in the Platinum-rated GBI office building located in Putrajaya Malaysia. The aim of the study is to determine the current indoor performance of the selected green office building. The field measurement consists of several IEQ parameters counted under the GBI Malaysia namely the Thermal Comfort of temperature, relative humidity, air movement and heat transfer as well as solar radiation. This field measurement also comprises of the measurement for the background noise, visual lighting and Indoor Air Quality (IAQ) focusing on the aspect of carbon dioxide concentration. All the selected indoor parameters were measured for the period of five working days and the results were compared to the Malaysian Standard. Findings of the field measurement show good indoor performance of the Platinum rated office building that complies with the GBI standard. It is hoped that the research findings will be beneficial for future design and construction of office building intended to be rated under the GBI Malaysia.

  6. Temporal variability and climatology of hydrodynamic, water property and water quality parameters in the West Johor Strait of Singapore.

    PubMed

    Behera, Manasa Ranjan; Chun, Cui; Palani, Sundarambal; Tkalich, Pavel

    2013-12-15

    The study presents a baseline variability and climatology study of measured hydrodynamic, water properties and some water quality parameters of West Johor Strait, Singapore at hourly-to-seasonal scales to uncover their dependency and correlation to one or more drivers. The considered parameters include, but not limited by sea surface elevation, current magnitude and direction, solar radiation and air temperature, water temperature, salinity, chlorophyll-a and turbidity. FFT (Fast Fourier Transform) analysis is carried out for the parameters to delineate relative effect of tidal and weather drivers. The group and individual correlations between the parameters are obtained by principal component analysis (PCA) and cross-correlation (CC) technique, respectively. The CC technique also identifies the dependency and time lag between driving natural forces and dependent water property and water quality parameters. The temporal variability and climatology of the driving forces and the dependent parameters are established at the hourly, daily, fortnightly and seasonal scales. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Generator Dynamic Model Validation and Parameter Calibration Using Phasor Measurements at the Point of Connection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Zhenyu; Du, Pengwei; Kosterev, Dmitry

    2013-05-01

    Disturbance data recorded by phasor measurement units (PMU) offers opportunities to improve the integrity of dynamic models. However, manually tuning parameters through play-back events demands significant efforts and engineering experiences. In this paper, a calibration method using the extended Kalman filter (EKF) technique is proposed. The formulation of EKF with parameter calibration is discussed. Case studies are presented to demonstrate its validity. The proposed calibration method is cost-effective, complementary to traditional equipment testing for improving dynamic model quality.

  8. History of water quality parameters - a study on the Sinos River/Brazil.

    PubMed

    Konzen, G B; Figueiredo, J A S; Quevedo, D M

    2015-05-01

    Water is increasingly becoming a valuable resource, constituting one of the central themes of environmental, economic and social discussions. The Sinos River, located in southern Brazil, is the main river from the Sinos River Basin, representing a source of drinking water supply for a highly populated region. Considering its size and importance, it becomes necessary to conduct a study to follow up the water quality of this river, which is considered by some experts as one of the most polluted rivers in Brazil. As for this study, its great importance lies in the historical analysis of indicators. In this sense, we sought to develop aspects related to the management of water resources by performing a historical analysis of the Water Quality Index (WQI) of the Sinos River, using statistical methods. With regard to the methodological procedures, it should be pointed out that this study performs a time analysis of monitoring data on parameters related to a punctual measurement that is variable in time, using statistical tools. The data used refer to analyses of the water quality of the Sinos River (WQI) from the State Environmental Protection Agency Henrique Luiz Roessler (Fundação Estadual de Proteção Ambiental Henrique Luiz Roessler, FEPAM) covering the period between 2000 and 2008, as well as to a theoretical analysis focusing on the management of water resources. The study of WQI and its parameters by statistical analysis has shown to be effective, ensuring its effectiveness as a tool for the management of water resources. The descriptive analysis of the WQI and its parameters showed that the water quality of the Sinos River is concerning low, which reaffirms that it is one of the most polluted rivers in Brazil. It should be highlighted that there was an overall difficulty in obtaining data with the appropriate periodicity, as well as a long complete series, which limited the conduction of statistical studies such as the present one.

  9. Influence of meteorological parameters on air quality

    NASA Astrophysics Data System (ADS)

    Gioda, Adriana; Ventura, Luciana; Lima, Igor; Luna, Aderval

    2013-04-01

    The physical characterization representative of ambient air particle concentrations is becoming a topic of great interest for urban air quality monitoring and human exposure assessment. Human exposure to particulate matter of less than 2.5 µm in diameter (PM2.5) can result in a variety of adverse health impacts, including reduced lung function and premature mortality. Numerous studies have shown that fine airborne inhalable particulate matter particles (PM2.5) are more dangerous to human health than coarse particles, e.g. PM10. This study investigates meteorological parameter impacts on PM2.5 concentrations in the atmosphere of Rio de Janeiro, Brazil. Samples were collected during 24 h every six days using a high-volume sampler from six sites in the metropolitan area of Rio de Janeiro from January to December 2011. The particles mass was determined by Gravimetry. Meteorological parameters were obtained from automatic stations near the sampling sites. The average PM2.5 concentrations ranged from 9 to 32 µg/m3 for all sites, exceeding the suggested annual limit of WHO (10 µg/m3). The relationship between the effects of temperature, relative humidity, wind speed and direction and particle concentration was examined using a Principal Component Analysis (PCA) for the different sites and seasons. The results for each sampling point and season presented different principal component numbers, varying from 2 to 4, and extremely different relationships with the parameters. This clearly shows that changes in meteorological conditions exert a marked influence on air quality.

  10. Transmission Electron Microscope Measures Lattice Parameters

    NASA Technical Reports Server (NTRS)

    Pike, William T.

    1996-01-01

    Convergent-beam microdiffraction (CBM) in thermionic-emission transmission electron microscope (TEM) is technique for measuring lattice parameters of nanometer-sized specimens of crystalline materials. Lattice parameters determined by use of CBM accurate to within few parts in thousand. Technique developed especially for use in quantifying lattice parameters, and thus strains, in epitaxial mismatched-crystal-lattice multilayer structures in multiple-quantum-well and other advanced semiconductor electronic devices. Ability to determine strains in indivdual layers contributes to understanding of novel electronic behaviors of devices.

  11. Measurement of drill grinding parameters using laser sensor

    NASA Astrophysics Data System (ADS)

    Yanping, Peng; Kumehara, Hiroyuki; Wei, Zhang; Nomura, Takashi

    2005-12-01

    To measure the grinding parameters and geometry parameters accurately for a drill point is essential to its design and reconditioning. In recent years, a number of non-contact coordinate measuring apparatuses, using CCD camera or laser sensors, are developed. But, a lot work is to be done for further improvement. This paper reports another kind of laser coordinate meter. As an example of its application, the method for geometry inspection of the drill flank surface is detailed. Measured data from laser scanning on the flank surface around some points with several 2-dimensional curves are analyzed with mathematical procedure. If one of these curves turns to be a straight line, it must be the generatrix of the grinding cone. Thus, the grinding parameters are determined by a set of three generatrices. Then, the measurement method and data processing procedure are proposed. Its validity is assessed by measuring a sample with given parameters. The point geometry measured agrees well with the known values. In comparison with other methods in the published literature, it is simpler in computation and more accurate in results.

  12. Measurement bias detection with Kronecker product restricted models for multivariate longitudinal data: an illustration with health-related quality of life data from thirteen measurement occasions.

    PubMed

    Verdam, Mathilde G E; Oort, Frans J

    2014-01-01

    Application of Kronecker product to construct parsimonious structural equation models for multivariate longitudinal data.A method for the investigation of measurement bias with Kronecker product restricted models.Application of these methods to health-related quality of life data from bone metastasis patients, collected at 13 consecutive measurement occasions.The use of curves to facilitate substantive interpretation of apparent measurement bias.Assessment of change in common factor means, after accounting for apparent measurement bias.Longitudinal measurement invariance is usually investigated with a longitudinal factor model (LFM). However, with multiple measurement occasions, the number of parameters to be estimated increases with a multiple of the number of measurement occasions. To guard against too low ratios of numbers of subjects and numbers of parameters, we can use Kronecker product restrictions to model the multivariate longitudinal structure of the data. These restrictions can be imposed on all parameter matrices, including measurement invariance restrictions on factor loadings and intercepts. The resulting models are parsimonious and have attractive interpretation, but require different methods for the investigation of measurement bias. Specifically, additional parameter matrices are introduced to accommodate possible violations of measurement invariance. These additional matrices consist of measurement bias parameters that are either fixed at zero or free to be estimated. In cases of measurement bias, it is also possible to model the bias over time, e.g., with linear or non-linear curves. Measurement bias detection with Kronecker product restricted models will be illustrated with multivariate longitudinal data from 682 bone metastasis patients whose health-related quality of life (HRQL) was measured at 13 consecutive weeks.

  13. Measuring Quality in Ethics Consultation.

    PubMed

    Bliss, Sally E; Oppenlander, Jane; Dahlke, Jacob M; Meyer, Gordon J; Williford, Eva M; Macauley, Robert C

    2016-01-01

    For all of the emphasis on quality improvement-as well as the acknowledged overlap between assessment of the quality of healthcare services and clinical ethics-the quality of clinical ethics consultation has received scant attention, especially in terms of empirical measurement. Recognizing this need, the second edition of Core Competencies for Health Care Ethics Consultation1 identified four domains of ethics quality: (1) ethicality, (2) stakeholders' satisfaction, (3) resolution of the presenting conflict/dilemma, and (4) education that translates into knowledge. This study is the first, to our knowledge, to directly measure all of these domains. Here we describe the quality improvement process undertaken at a tertiary care academic medical center, as well as the tools developed to measure the quality of ethics consultation, which include post-consultation satisfaction surveys and weekly case conferences. The information gained through these tools helps to improve not only the process of ethics consultation, but also the measurement and assurance of quality. Copyright 2016 The Journal of Clinical Ethics. All rights reserved.

  14. Earnings Quality Measures and Excess Returns

    PubMed Central

    Perotti, Pietro; Wagenhofer, Alfred

    2014-01-01

    This paper examines how commonly used earnings quality measures fulfill a key objective of financial reporting, i.e., improving decision usefulness for investors. We propose a stock-price-based measure for assessing the quality of earnings quality measures. We predict that firms with higher earnings quality will be less mispriced than other firms. Mispricing is measured by the difference of the mean absolute excess returns of portfolios formed on high and low values of a measure. We examine persistence, predictability, two measures of smoothness, abnormal accruals, accruals quality, earnings response coefficient and value relevance. For a large sample of US non-financial firms over the period 1988–2007, we show that all measures except for smoothness are negatively associated with absolute excess returns, suggesting that smoothness is generally a favorable attribute of earnings. Accruals measures generate the largest spread in absolute excess returns, followed by smoothness and market-based measures. These results lend support to the widespread use of accruals measures as overall measures of earnings quality in the literature. PMID:26300582

  15. Earnings Quality Measures and Excess Returns.

    PubMed

    Perotti, Pietro; Wagenhofer, Alfred

    2014-06-01

    This paper examines how commonly used earnings quality measures fulfill a key objective of financial reporting, i.e., improving decision usefulness for investors. We propose a stock-price-based measure for assessing the quality of earnings quality measures. We predict that firms with higher earnings quality will be less mispriced than other firms. Mispricing is measured by the difference of the mean absolute excess returns of portfolios formed on high and low values of a measure. We examine persistence, predictability, two measures of smoothness, abnormal accruals, accruals quality, earnings response coefficient and value relevance. For a large sample of US non-financial firms over the period 1988-2007, we show that all measures except for smoothness are negatively associated with absolute excess returns, suggesting that smoothness is generally a favorable attribute of earnings. Accruals measures generate the largest spread in absolute excess returns, followed by smoothness and market-based measures. These results lend support to the widespread use of accruals measures as overall measures of earnings quality in the literature.

  16. Quality improvement in neurology: AAN Parkinson disease quality measures

    PubMed Central

    Cheng, E.M.; Tonn, S.; Swain-Eng, R.; Factor, S.A.; Weiner, W.J.; Bever, C.T.

    2010-01-01

    Background: Measuring the quality of health care is a fundamental step toward improving health care and is increasingly used in pay-for-performance initiatives and maintenance of certification requirements. Measure development to date has focused on primary care and common conditions such as diabetes; thus, the number of measures that apply to neurologic care is limited. The American Academy of Neurology (AAN) identified the need for neurologists to develop measures of neurologic care and to establish a process to accomplish this. Objective: To adapt and test the feasibility of a process for independent development by the AAN of measures for neurologic conditions for national measurement programs. Methods: A process that has been used nationally for measure development was adapted for use by the AAN. Topics for measure development are chosen based upon national priorities, available evidence base from a systematic literature search, gaps in care, and the potential impact for quality improvement. A panel composed of subject matter and measure development methodology experts oversees the development of the measures. Recommendation statements and their corresponding level of evidence are reviewed and considered for development into draft candidate measures. The candidate measures are refined by the expert panel during a 30-day public comment period and by review by the American Medical Association for Current Procedural Terminology (CPT) II codes. All final AAN measures are approved by the AAN Board of Directors. Results: Parkinson disease (PD) was chosen for measure development. A review of the medical literature identified 258 relevant recommendation statements. A 28-member panel approved 10 quality measures for PD that included full specifications and CPT II codes. Conclusion: The AAN has adapted a measure development process that is suitable for national measurement programs and has demonstrated its capability to independently develop quality measures. GLOSSARY

  17. Correlation pattern recognition: optimal parameters for quality standards control of chocolate marshmallow candy

    NASA Astrophysics Data System (ADS)

    Flores, Jorge L.; García-Torales, G.; Ponce Ávila, Cristina

    2006-08-01

    This paper describes an in situ image recognition system designed to inspect the quality standards of the chocolate pops during their production. The essence of the recognition system is the localization of the events (i.e., defects) in the input images that affect the quality standards of pops. To this end, processing modules, based on correlation filter, and segmentation of images are employed with the objective of measuring the quality standards. Therefore, we designed the correlation filter and defined a set of features from the correlation plane. The desired values for these parameters are obtained by exploiting information about objects to be rejected in order to find the optimal discrimination capability of the system. Regarding this set of features, the pop can be correctly classified. The efficacy of the system has been tested thoroughly under laboratory conditions using at least 50 images, containing 3 different types of possible defects.

  18. The Use of Logistics n the Quality Parameters Control System of Material Flow

    ERIC Educational Resources Information Center

    Karpova, Natalia P.; Toymentseva, Irina A.; Shvetsova, Elena V.; Chichkina, Vera D.; Chubarkova, Elena V.

    2016-01-01

    The relevance of the research problem is conditioned on the need to justify the use of the logistics methodologies in the quality parameters control process of material flows. The goal of the article is to develop theoretical principles and practical recommendations for logistical system control in material flows quality parameters. A leading…

  19. New approach for rapid assessment of trophic status of Yellow Sea and East China Sea using easy-to-measure parameters

    NASA Astrophysics Data System (ADS)

    Kong, Xianyu; Liu, Yanfang; Jian, Huimin; Su, Rongguo; Yao, Qingzhen; Shi, Xiaoyong

    2017-10-01

    To realize potential cost savings in coastal monitoring programs and provide timely advice for marine management, there is an urgent need for efficient evaluation tools based on easily measured variables for the rapid and timely assessment of estuarine and offshore eutrophication. In this study, using parallel factor analysis (PARAFAC), principal component analysis (PCA), and discriminant function analysis (DFA) with the trophic index (TRIX) for reference, we developed an approach for rapidly assessing the eutrophication status of coastal waters using easy-to-measure parameters, including chromophoric dissolved organic matter (CDOM), fluorescence excitation-emission matrices, CDOM UV-Vis absorbance, and other water-quality parameters (turbidity, chlorophyll a, and dissolved oxygen). First, we decomposed CDOM excitation-emission matrices (EEMs) by PARAFAC to identify three components. Then, we applied PCA to simplify the complexity of the relationships between the water-quality parameters. Finally, we used the PCA score values as independent variables in DFA to develop a eutrophication assessment model. The developed model yielded classification accuracy rates of 97.1%, 80.5%, 90.3%, and 89.1% for good, moderate, and poor water qualities, and for the overall data sets, respectively. Our results suggest that these easy-to-measure parameters could be used to develop a simple approach for rapid in-situ assessment and monitoring of the eutrophication of estuarine and offshore areas.

  20. Candidate Quality Measures for Hand Surgery.

    PubMed

    2017-11-01

    Quality measures are tools used by physicians, health care systems, and payers to evaluate performance, monitor the outcomes of interventions, and inform quality improvement efforts. A paucity of quality measures exist that address hand surgery care. We completed a RAND/UCLA (University of California Los Angeles) Delphi Appropriateness process with the goal of developing and evaluating candidate hand surgery quality measures to be used for national quality measure development efforts. A consortium of 9 academic upper limb surgeons completed a RAND/UCLA Delphi Appropriateness process to evaluate the importance, scientific acceptability, usability, and feasibility of 44 candidate quality measures. These addressed hand problems the panelists felt were most appropriate for quality measure development. Panelists rated the measures on an ordinal scale between 1 (definitely not valid) and 9 (definitely valid) in 2 rounds (preliminary round and final round) with an intervening face-to-face discussion. Ratings from 1 to 3 were considered not valid, 4 to 6 as equivocal or uncertain, and 7 to 9 as valid. If no more than 2 of the 9 ratings were outside the 3-point range that included the median (1-3, 4-6, or 7-9), the panelists were considered to be in agreement. If 3 or more of the panelists' ratings of a measure were within the 1 to 3 range and 3 or more ratings were in the 7 to 9 range, the panelists were considered to be in disagreement. There was agreement on 43% (19) of the measures as important, 27% (12) as scientifically sound, 48% (21) as usable, and 59% (26) as feasible to complete. Ten measures met all 4 of these criteria and were, therefore, considered valid measurements of quality. Quality measures that were developed address outcomes (patient-reported outcomes for assessment and improvement of function) and processes of care (utilization rates of imaging, antibiotics, occupational therapy, ultrasound, and operative treatment). The consortium developed 10

  1. Biomonitoring of water quality of the Osumi, Devolli, and Shkumbini rivers through benthic macroinvertebrates and chemical parameters.

    PubMed

    Duka, Sonila; Pepa, Bledar; Keci, Erjola; Paparisto, Anila; Lazo, Pranvera

    2017-04-16

    Environmental monitoring of river water quality in Albania, using biological and chemical parameters, is a fast and effective way to assess the quality of water bodies.The aim of this study was to investigate Ephemeroptera, Plecoptera and Trichoptera (EPT), Biotic index-Richness using macroinvertebrates to assess the water quality, with special reference to nutrient (phosphorus and nitrogen) levels in the Devolli, Shkumbini and Osumi rivers. Our objective was to investigate the relationships between the measures of benthic macroinvertebrate communities and nutrient concentrations to assess water quality. The rivers' benthic macroinvertebrates were collected during different seasons in 2012. The biological and chemical parameters used in the current study identified them as quick indicators of water quality assessment. The total number of macroinvertebrate individuals (n = 15,006) (Osumi river: n = 5,546 organisms; Devolli river: n = 3,469 organisms; and Shkumbini river: n = 5,991 organisms), together with the EPT group (Ephemeroptera, Plecoptera, and Trichoptera), showed that the water quality at the river stations during the above-mentioned period belonged to Classes II and III (fair water quality and good water quality, respectively). The classification of the water quality was also based on the nitrogen and total phosphorus contents. The pollution tolerance levels of macroinvertebrate taxa varied from the non-tolerating forms encountered in environments with low pollution levels to the tolerating forms that are typical of environments with considerable pollution levels.

  2. The effect of welding parameters on surface quality of AA6351 aluminium alloy

    NASA Astrophysics Data System (ADS)

    Yacob, S.; MAli, M. A.; Ahsan, Q.; Ariffin, N.; Ali, R.; Arshad, A.; Wahab, M. I. A.; Ismail, S. A.; Roji, NS M.; Din, W. B. W.; Zakaria, M. H.; Abdullah, A.; Yusof, M. I.; Kamarulzaman, K. Z.; Mahyuddin, A.; Hamzah, M. N.; Roslan, R.

    2015-12-01

    In the present work, the effects of gas metal arc welding-cold metal transfer (GMAW-CMT) parameters on surface roughness are experimentally assessed. The purpose of this study is to develop a better understanding of the effects of welding speed, material thickness and contact tip to work distance on the surface roughness. Experiments are conducted using single pass gas metal arc welding-cold metal transfer (GMAW-CMT) welding technique to join the material. The material used in this experiment was AA6351 aluminum alloy with the thickness of 5mm and 6mm. A Mahr Marsuft XR 20 machine was used to measure the average roughness (Ra) of AA6351 joints. The main and interaction effect analysis was carried out to identify process parameters that affect the surface roughness. The results show that all the input process parameters affect the surface roughness of AA6351 joints. Additionally, the average roughness (Ra) results also show a decreasing trend with increased of welding speed. It is proven that gas metal arc welding-cold metal transfer (GMAW-CMT)welding process has been successful in term of providing weld joint of good surface quality for AA6351 based on the low value surface roughness condition obtained in this setup. The outcome of this experimental shall be valuable for future fabrication process in order to obtained high good quality weld.

  3. Suspension Parameter Measurements of Wheeled Military Vehicles

    DTIC Science & Technology

    2012-08-01

    suspension through the wheel pads. The SPIdER was designed so that in the future, with a modest amount of modification , it can be upgraded to include the...AND MOBILITY (P&M) MINI-SYMPOSIUM AUGUST 14-16, MICHIGAN SUSPENSION PARAMETER MEASUREMENTS OF WHEELED MILITARY VEHICLES Dale Andreatta Gary...was built to measure the suspension parameters of any military wheeled vehicle. This is part of an ongoing effort to model and predict vehicle

  4. Investigation of water quality parameters at selected points on the Tennessee River

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The thermal and water quality parameters in the vicinity of widows Creek Steam Generation Plant were investigated. The water quality analysis and temperature profiles are presented for 24 sampling sites.

  5. Stability evaluation of quality parameters for palm oil products at low temperature storage.

    PubMed

    Ramli, Nur Aainaa Syahirah; Mohd Noor, Mohd Azmil; Musa, Hajar; Ghazali, Razmah

    2018-07-01

    Palm oil is one of the major oils and fats produced and traded worldwide. The value of palm oil products is mainly influenced by their quality. According to ISO 17025:2005, accredited laboratories require a quality control procedure with respect to monitoring the validity of tests for determination of quality parameters. This includes the regular use of internal quality control using secondary reference materials. Unfortunately, palm oil reference materials are not currently available. To establish internal quality control samples, the stability of quality parameters needs to be evaluated. In the present study, the stability of quality parameters for palm oil products was examined over 10 months at low temperature storage (6 ± 2 °C). The palm oil products tested included crude palm oil (CPO); refined, bleached and deodorized (RBD) palm oil (RBDPO); RBD palm olein (RBDPOo); and RBD palm stearin (RBDPS). The quality parameters of the oils [i.e. moisture content, free fatty acid content (FFA), iodine value (IV), fatty acids composition (FAC) and slip melting point (SMP)] were determined prior to and throughout the storage period. The moisture, FFA, IV, FAC and SMP for palm oil products changed significantly (P < 0.05), whereas the moisture content for CPO, IV for RBDPO and RBDPOo, stearic acid composition for CPO and linolenic acid composition for CPO, RBDPO, RBDPOo and RBDPS did not (P > 0.05). The stability study indicated that the quality of the palm oil products was stable within the specified limits throughout the storage period at low temperature. The storage conditions preserved the quality of palm oil products throughout the storage period. These findings qualify the use of the palm oil products CPO, RBDPO, RBDPOo and RBDPS as control samples in the validation of test results. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  6. Measurement bias detection with Kronecker product restricted models for multivariate longitudinal data: an illustration with health-related quality of life data from thirteen measurement occasions

    PubMed Central

    Verdam, Mathilde G. E.; Oort, Frans J.

    2014-01-01

    Highlights Application of Kronecker product to construct parsimonious structural equation models for multivariate longitudinal data. A method for the investigation of measurement bias with Kronecker product restricted models. Application of these methods to health-related quality of life data from bone metastasis patients, collected at 13 consecutive measurement occasions. The use of curves to facilitate substantive interpretation of apparent measurement bias. Assessment of change in common factor means, after accounting for apparent measurement bias. Longitudinal measurement invariance is usually investigated with a longitudinal factor model (LFM). However, with multiple measurement occasions, the number of parameters to be estimated increases with a multiple of the number of measurement occasions. To guard against too low ratios of numbers of subjects and numbers of parameters, we can use Kronecker product restrictions to model the multivariate longitudinal structure of the data. These restrictions can be imposed on all parameter matrices, including measurement invariance restrictions on factor loadings and intercepts. The resulting models are parsimonious and have attractive interpretation, but require different methods for the investigation of measurement bias. Specifically, additional parameter matrices are introduced to accommodate possible violations of measurement invariance. These additional matrices consist of measurement bias parameters that are either fixed at zero or free to be estimated. In cases of measurement bias, it is also possible to model the bias over time, e.g., with linear or non-linear curves. Measurement bias detection with Kronecker product restricted models will be illustrated with multivariate longitudinal data from 682 bone metastasis patients whose health-related quality of life (HRQL) was measured at 13 consecutive weeks. PMID:25295016

  7. Genetic parameters of egg defects and egg quality in layer chickens.

    PubMed

    Wolc, A; Arango, J; Settar, P; O'Sullivan, N P; Olori, V E; White, I M S; Hill, W G; Dekkers, J C M

    2012-06-01

    Genetic parameters were estimated for egg defects, egg production, and egg quality traits. Eggs from 11,738 purebred brown-egg laying hens were classified as salable or as having one of the following defects: bloody, broken, calcium deposit, dirty, double yolk, misshapen, pee-wee, shell-less, and soft shelled. Egg quality included albumen height, egg weight, yolk weight, and puncture score. Body weight, age at sexual maturity, and egg production were also recorded. Heritability estimates of liability to defects using a threshold animal model were less than 0.1 for bloody and dirty; between 0.1 and 0.2 for pee-wee, broken, misshapen, soft shelled, and shell-less; and above 0.2 for calcium deposit and double yolk. Quality and production traits were more heritable, with estimates ranging from 0.29 (puncture score) to 0.74 (egg weight). High-producing hens had a lower frequency of egg defects. High egg weight and BW were associated with an increased frequency of double yolks, and to a lesser extent, with more shell quality defects. Estimates of genetic correlations among defect traits that were related to shell quality were positive and moderate to strong (0.24-0.73), suggesting that these could be grouped into one category or selection could be based on the trait with the highest heritability or that is easiest to measure. Selection against defective eggs would be more efficient by including egg defect traits in the selection criterion, along with egg production rate of salable eggs and egg quality traits.

  8. A standard for measuring metadata quality in spectral libraries

    NASA Astrophysics Data System (ADS)

    Rasaiah, B.; Jones, S. D.; Bellman, C.

    2013-12-01

    A standard for measuring metadata quality in spectral libraries Barbara Rasaiah, Simon Jones, Chris Bellman RMIT University Melbourne, Australia barbara.rasaiah@rmit.edu.au, simon.jones@rmit.edu.au, chris.bellman@rmit.edu.au ABSTRACT There is an urgent need within the international remote sensing community to establish a metadata standard for field spectroscopy that ensures high quality, interoperable metadata sets that can be archived and shared efficiently within Earth observation data sharing systems. Metadata are an important component in the cataloguing and analysis of in situ spectroscopy datasets because of their central role in identifying and quantifying the quality and reliability of spectral data and the products derived from them. This paper presents approaches to measuring metadata completeness and quality in spectral libraries to determine reliability, interoperability, and re-useability of a dataset. Explored are quality parameters that meet the unique requirements of in situ spectroscopy datasets, across many campaigns. Examined are the challenges presented by ensuring that data creators, owners, and data users ensure a high level of data integrity throughout the lifecycle of a dataset. Issues such as field measurement methods, instrument calibration, and data representativeness are investigated. The proposed metadata standard incorporates expert recommendations that include metadata protocols critical to all campaigns, and those that are restricted to campaigns for specific target measurements. The implication of semantics and syntax for a robust and flexible metadata standard are also considered. Approaches towards an operational and logistically viable implementation of a quality standard are discussed. This paper also proposes a way forward for adapting and enhancing current geospatial metadata standards to the unique requirements of field spectroscopy metadata quality. [0430] BIOGEOSCIENCES / Computational methods and data processing [0480

  9. Quality of vision in refractive and cataract surgery, indirect measurers: review article.

    PubMed

    Parede, Taís Renata Ribeira; Torricelli, André Augusto Miranda; Mukai, Adriana; Vieira Netto, Marcelo; Bechara, Samir Jacob

    2013-01-01

    Visual acuity is the measurement of an individual's ability to recognize details of an object in a space. Visual function measurements in clinical ophthalmology are limited by factors such as maximum contrast and so it might not adequately reflect the real vision conditions at that moment as well as the subjective aspects of the world perception by the patient. The objective of a successful vision-restoring surgery lies not only in gaining visual acuity lines, but also in vision quality. Therefore, refractive and cataract surgeries have the responsibility of achieving quality results. It is difficult to define quality of vision by a single parameter, and the main functional-vision tests are: contrast sensitivity, disability glare, intraocular stray light and aberrometry. In the current review the different components of the visual function are explained and the several available methods to assess the vision quality are described.

  10. Water Quality Index for measuring drinking water quality in rural Bangladesh: a cross-sectional study.

    PubMed

    Akter, Tahera; Jhohura, Fatema Tuz; Akter, Fahmida; Chowdhury, Tridib Roy; Mistry, Sabuj Kanti; Dey, Digbijoy; Barua, Milan Kanti; Islam, Md Akramul; Rahman, Mahfuzar

    2016-02-09

    Public health is at risk due to chemical contaminants in drinking water which may have immediate health consequences. Drinking water sources are susceptible to pollutants depending on geological conditions and agricultural, industrial, and other man-made activities. Ensuring the safety of drinking water is, therefore, a growing problem. To assess drinking water quality, we measured multiple chemical parameters in drinking water samples from across Bangladesh with the aim of improving public health interventions. In this cross-sectional study conducted in 24 randomly selected upazilas, arsenic was measured in drinking water in the field using an arsenic testing kit and a sub-sample was validated in the laboratory. Water samples were collected to test water pH in the laboratory as well as a sub-sample of collected drinking water was tested for water pH using a portable pH meter. For laboratory testing of other chemical parameters, iron, manganese, and salinity, drinking water samples were collected from 12 out of 24 upazilas. Drinking water at sample sites was slightly alkaline (pH 7.4 ± 0.4) but within acceptable limits. Manganese concentrations varied from 0.1 to 5.5 mg/L with a median value of 0.2 mg/L. The median iron concentrations in water exceeded WHO standards (0.3 mg/L) at most of the sample sites and exceeded Bangladesh standards (1.0 mg/L) at a few sample sites. Salinity was relatively higher in coastal districts. After laboratory confirmation, arsenic concentrations were found higher in Shibchar (Madaripur) and Alfadanga (Faridpur) compared to other sample sites exceeding WHO standard (0.01 mg/L). Of the total sampling sites, 33 % had good-quality water for drinking based on the Water Quality Index (WQI). However, the majority of the households (67 %) used poor-quality drinking water. Higher values of iron, manganese, and arsenic reduced drinking water quality. Awareness raising on chemical contents in drinking water at household level is required to

  11. Quality inspection of anisotropic scintillating lead tungstate (PbWO 4) crystals through measurement of interferometric fringe pattern parameters

    NASA Astrophysics Data System (ADS)

    Cocozzella, N.; Lebeau, M.; Majni, G.; Paone, N.; Rinaldi, D.

    2001-08-01

    Scintillating crystals are widely used as detectors in radiographic systems, computerized axial tomography devices and in calorimeters employed in high-energy physics. This paper results from a project motivated by the development of the CMS calorimeter at CERN, which will make use of a large number of scintillating crystals. In order to prevent crystals from breaking because of internal residual stress, a quality control system based on optic inspection of interference fringe patterns was developed. The principle of measurement procedures was theoretically modelled, and then a dedicated polariscope was designed and built, in order to observe the crystals under induced stresses or to evaluate the residual internal stresses. The results are innovative and open a new perspective for scintillating crystals quality control: the photoelastic constant normal to the optic axis of the lead tungstate crystals (PbWO 4) was measured, and the inspection procedure developed is applicable to mass production, not only to optimize the crystal processing, but also to establish a quality inspection procedure.

  12. Parameters of Higher Education Quality Assessment System at Universities

    ERIC Educational Resources Information Center

    Savickiene, Izabela

    2005-01-01

    The article analyses the system of institutional quality assessment at universities and lays foundation to its functional, morphological and processual parameters. It also presents the concept of the system and discusses the distribution of systems into groups, defines information, accountability, improvement and benchmarking functions of higher…

  13. Evaluation of multivariate linear regression and artificial neural networks in prediction of water quality parameters

    PubMed Central

    2014-01-01

    This paper examined the efficiency of multivariate linear regression (MLR) and artificial neural network (ANN) models in prediction of two major water quality parameters in a wastewater treatment plant. Biochemical oxygen demand (BOD) and chemical oxygen demand (COD) as well as indirect indicators of organic matters are representative parameters for sewer water quality. Performance of the ANN models was evaluated using coefficient of correlation (r), root mean square error (RMSE) and bias values. The computed values of BOD and COD by model, ANN method and regression analysis were in close agreement with their respective measured values. Results showed that the ANN performance model was better than the MLR model. Comparative indices of the optimized ANN with input values of temperature (T), pH, total suspended solid (TSS) and total suspended (TS) for prediction of BOD was RMSE = 25.1 mg/L, r = 0.83 and for prediction of COD was RMSE = 49.4 mg/L, r = 0.81. It was found that the ANN model could be employed successfully in estimating the BOD and COD in the inlet of wastewater biochemical treatment plants. Moreover, sensitive examination results showed that pH parameter have more effect on BOD and COD predicting to another parameters. Also, both implemented models have predicted BOD better than COD. PMID:24456676

  14. Development of colour and firmness in strawberry crops is UV light sensitive, but colour is not a good predictor of several quality parameters.

    PubMed

    Ordidge, Matthew; García-Macías, Paulina; Battey, Nicholas H; Gordon, Michael H; John, Philip; Lovegrove, Julie A; Vysini, Eleni; Wagstaffe, Alexandra; Hadley, Paul

    2012-06-01

    Strawberry (Fragaria × ananassa Duchesne var. Elsanta) plants were grown in polytunnels covered with three polythene films that transmitted varying levels of ultraviolet (UV) light. Fruit were harvested under near-commercial conditions and quality and yield were measured. During ripening, changes in the colour parameters of individual fruit were monitored, and the accuracy of using surface colour to predict other quality parameters was determined by analysing the correlation between colour and quality parameters within UV treatments. Higher exposure to UV during growth resulted in the fruit becoming darker at harvest and developing surface colour more quickly; fruit were also firmer at harvest, but shelf life was not consistently affected by the UV regime. Surface colour measurements were poorly correlated to firmness, shelf life or total phenolics, anthocyanins and ellagic acid contents. Although surface colour of strawberry fruits was affected by the UV regime during growth, and this parameter is an important factor in consumer perception, we concluded that the surface colour at the time of harvest was, contrary to consumer expectations, a poor indicator of firmness, potential shelf life or anthocyanin content. Copyright © 2011 Society of Chemical Industry.

  15. Investigation of water quality parameters at selected points on the Tennessee River

    NASA Technical Reports Server (NTRS)

    Manger, M. C.

    1973-01-01

    Physical, chemical, and biological water quality parameters have been investigated at the Widow's Creek steam plant. The water quality parameters and field site locations have been selected so as to be compatible with the interests and needs of the Environmental Application Office at Marshall Space Flight Center. All sampling and testing was conducted as directed in the 13th Edition of Standard Methods of Analysis for Water and Waste Water or as suggested by NASA'S Technical Officer. Data is presented in a form compatible with that presently being collected by other agencies.

  16. Deforestation effects on soil quality and water retention curve parameters in eastern Ardabil, Iran

    NASA Astrophysics Data System (ADS)

    Asghari, Sh.; Ahmadnejad, S.; Keivan Behjou, F.

    2016-03-01

    The land use change from natural to managed ecosystems causes serious soil degradation. The main objective of this research was to assess deforestation effects on soil physical quality attributes and soil water retention curve (SWRC) parameters in the Fandoghlou region of Ardabil province, Iran. Totally 36 surface and subsurface soil samples were taken and soil water contents measured at 13 suctions. Alfa (α) and n parameters in van Genuchten (1980) model were estimated by fitting SWRC data by using RETC software. The slope of SWRC at inflection point (SP) was calculated by Dexter (2004) equation. The results indicated that with changing land use from forest (F) to range land (R) and cultivated land (C), and also with increasing soil depth from 0-25 to 75-100 cm in each land use, organic carbon, micropores, saturated and available water contents decreased and macropores and bulk density increased significantly ( P < 0.05). The position of SWRC shape in F was higher than R and C lands at all soil depths. Changing F to R and C lands and also increasing soil depth in each land use significantly ( P < 0.05) increased α and decreased n and SP. The average values of SP were obtained 0.093, 0.051 and 0.031 for F, R and C, respectively. As a result, deforestation reduced soil physical quality by affecting SWRC parameters.

  17. Quality parameters and antioxidant and antibacterial properties of some Mexican honeys.

    PubMed

    Rodríguez, Beatriz A; Mendoza, Sandra; Iturriga, Montserrat H; Castaño-Tostado, Eduardo

    2012-01-01

    A total of 14 Mexican honeys were screened for quality parameters including color, moisture, proline, and acidity. Antioxidant properties of complete honey and its methanolic extracts were evaluated by the DPPH, ABTS, and FRAP assays. In addition, the antimicrobial activity of complete honeys against Bacillus cereus ATCC 10876, Listeria monocytogenes Scott A, Salmonella Typhimurium ATCC 14028, and Sthapylococcus aureus ATCC 6538 was determined. Most of honeys analyzed showed values within quality parameters established by the Codex Alimentarius Commission in 2001. Eucalyptus flower honey and orange blossom honey showed the highest phenolic contents and antioxidant capacity. Bell flower, orange blossom, and eucalyptus flower honeys inhibited the growth of the 4 evaluated microorganisms. The remaining honeys affected at least 1 of the estimated growth parameters (increased lag phase, decreased growth rate, and/or maximum population density). Microorganism sensitivity to the antimicrobial activity of honeys followed the order B. cereus > L. monocytogenes > Salmonella Typhimurium > S. aureus. The monofloral honey samples from orange blossoms, and eucalyptus flowers demonstrated to be good sources of antioxidant and antimicrobial compounds. All the Mexican honey samples examined proved to be good sources of antioxidants and antimicrobial agents that might serve to maintain health and protect against several diseases. The results of the study showed that Mexican honeys display good quality parameters and antioxidant and antimicrobial activities. Mexican honey can be used as an additive in the food industry to increase the nutraceutical value of products. © 2011 Institute of Food Technologists®

  18. Do Activity Level Outcome Measures Commonly Used in Neurological Practice Assess Upper-Limb Movement Quality?

    PubMed

    Demers, Marika; Levin, Mindy F

    2017-07-01

    Movement is described in terms of task-related end point characteristics in external space and movement quality (joint rotations in body space). Assessment of upper-limb (UL) movement quality can assist therapists in designing effective treatment approaches for retraining lost motor elements and provide more detailed measurements of UL motor improvements over time. To determine the extent to which current activity level outcome measures used in neurological practice assess UL movement quality. Outcome measures assessing arm/hand function at the International Classification of Function activity level recommended by neurological clinical practice guidelines were reviewed. Measures assessing the UL as part of a general mobility assessment, those strictly evaluating body function/structure or participation, and paediatric measures were excluded. In all, 15 activity level outcome measures were identified; 9 measures assess how movement is performed by measuring either end point characteristics or movement quality. However, except for the Reaching Performance Scale for Stroke and the Motor Evaluation Scale for Upper Extremity in Stroke Patients, these measures only account for deficits indirectly by giving a partial score if movements are slower or if the person experiences difficulties. Six outcome measures neither assess any parameters related to movement quality, nor distinguish between improvements resulting from motor compensation or recovery of desired movement strategies. Current activity measures may not distinguish recovery from compensation and adequately track changes in movement quality over time. Movement quality may be incorporated into clinical assessment using observational kinematics with or without low-cost motion tracking technology.

  19. Interplanetary plasma scintillation parameters measurements retrieved from the spacecraft observations.

    NASA Astrophysics Data System (ADS)

    Molera Calvés, Guifré; Pogrebenko, S. V.; Wagner, J.; Maccaferri, G.; Colucci, G.; Kronschnabl, G.; Scilliro, F.; Bianco, G.; Pérez Ayúcar, M.; Cosmovici, C. B.

    2010-05-01

    Measurement of the Interplanetary Scintillations (IPS) of radio signals propagating through the plasma in the Solar System by the radio astronomical instruments is a powerful tool to characterise and study the spatial and temporal variation of the electron density in the Solar wind. Several techniques based on the observation of natural and artificial radio sources have been developed during the last 50 years. Here we report our results of the IPS parameters measurement based on the multi-station observations of the planetary mission spacecraft. The ESA Venus Express spacecraft was observed at X-band (8.4 GHz) by several European VLBI stations - Metsähovi Radio Observatory (Aalto University , FI), Medicina (INAF-RA, IT), Matera (ASI, IT), Wettzell (BKG, DE), Noto (INAF-IRA, IT) and Yebes (OAN-IGN, ES) during a 2008-2010 campaign in a framework of the PRIDE (Planetary Radio Interferometry and Doppler Experiments) project as a preparatory stage for the European Radio Astronomy VLBI facilities participation in the planned ESA planetary missions (EJSM, TESM, EVE and others). Observational data were processed at Metsähovi Radio Observatory with the on-purpose developed high performance, ultra-high spectral resolution and spacecraft tracking capable software spectrometer-correlator and analysed at the Joint Institute for VLBI in Europe (JIVE, NL). High quality of acquired and analysed data enables us to study and define several parameters of the S/C signal and accompanying "ranging" tones with milli-Hz accuracy, among which the phase fluctuations of the spacecraft signal carrier line can be used to characterise the interplanetary plasma density fluctuations along the signal propagation line at different spatial and temporal scales at different Solar elongations and which exhibits a near-Kolmogorov spectrum. Such essential parameters as the phase scintillation index and bandwidth of scintillations and their dependence on the solar elongation, distance to the target

  20. National Survey on Internal Quality Control Practice for Lipid Parameters in Laboratories of China from 2014 to 2016.

    PubMed

    Ye, Yuanyuan; Wang, Wei; Zhao, Haijian; He, Falin; Zhong, Kun; Yuan, Shuai; Wang, Zhiguo

    2017-09-01

    To investigate the situation of Internal Quality Control (IQC) practice for total cholesterol, triglycerides, HDL-cholesterol and LDL-cholesterol from 2014 to 2016 in laboratories in China and provide improvement measurements. A web-based External Quality Assessment (EQA) system was used to collect IQC data of lipid parameters in laboratories which continuously participated in the national EQA programs in China from 2014 to 2016. Pass rate of the coefficients of variation (CVs) of two level quality controls in four lipid parameters were calculated according to six quality specifications for precision to evaluate the current status of precision level of the four lipid parameters and their change over time in China. 533, 512, 504, and 466 laboratories continuously reported the data of level one for total cholesterol, triglyceride, HDL-cholesterol and LDL-cholesterol, and 212, 210, 208 and 198 laboratories reported the level two, respectively. The percentage of laboratories meeting the quality specification varied based on different criteria. Non-significant change can be found in the pass rate of CVs over time. The number of laboratories using a closed system increased over time, but still only accounted for a small proportion. There is no significant difference in the pass rate of CVs between closed and open systems. Triglycerides currently have a fairly good performance in China. While the performance of laboratories on total cholesterol, HDL-cholesterol and LDL-cholesterol has yet to be improved.

  1. EFFECTS OF AROMATHERAPY MASSAGE ON THE SLEEP QUALITY AND PHYSIOLOGICAL PARAMETERS OF PATIENTS IN A SURGICAL INTENSIVE CARE UNIT.

    PubMed

    Özlü, Zeynep Karaman; Bilican, Pınar

    2017-01-01

    Surgical pain is experienced by inpatients with clinical, disease-related concerns, unknown encounters after surgery, quality of sleep, restrictions in position after surgery is known to be serious. The study was conducted to determine the effect of aromatherapy massage on quality of sleep and physiological parameters in surgical intensive care patients. This is an experimental study. The sample of this study consisted of 60 patients who were divided into two groups as experimental group and control group including 30 patients in each one. The participants were postoperative patients, absent complications, who were unconscious and extubated. A data collection form on personal characteristics of the patients, a registration form on their physical parameters and the Richards-Campbell Sleep Scale (RCSQ) were used to collect the data of the study. The Richards-Campbell Sleep Scale indicated that while the experimental group had a mean score of 53.80 ± 13.20, the control group had a mean score of 29.08 ± 9.71 and there was a statistically significant difference between mean scores of the groups. In a comparison of physiologic parameters, only diastolic blood pressure measuring between parameters in favor of an assembly as a statistically significant difference was detected. Results of the study showed that aromatherapy massage enhanced the sleep quality of patients in a surgical intensive care unit and resulted in some positive changes in their physiological parameters.

  2. Measurement of the Acoustic Nonlinearity Parameter for Biological Media.

    NASA Astrophysics Data System (ADS)

    Cobb, Wesley Nelson

    In vitro measurements of the acoustic nonlinearity parameter are presented for several biological media. With these measurements it is possible to predict the distortion of a finite amplitude wave in biological tissues of current diagnostic and research interest. The measurement method is based on the finite amplitude distortion of a sine wave that is emmitted by a piston source. The growth of the second harmonic component of this wave is measured by a piston receiver which is coaxial with and has the same size as the source. The experimental measurements and theory are compared in order to determine the nonlinearity parameter. The density, sound speed, and attenuation for the medium are determined in order to make this comparison. The theory developed for this study accounts for the influence of both diffraction and attenuation on the experimental measurements. The effects of dispersion, tissue inhomogeneity and gas bubbles within the excised tissues are studied. To test the measurement method, experimental results are compared with established values for the nonlinearity parameter of distilled water, ethylene glycol and glycerol. The agreement between these values suggests that the measurement uncertainty is (+OR-) 5% for liquids and (+OR-) 10% for solid tissues. Measurements are presented for dog blood and bovine serum albumen as a function of concentration. The nonlinearity parameters for liver, kidney and spleen are reported for both human and canine tissues. The values for the fresh tissues displayed little variation (6.8 to 7.8). Measurements for fixed, normal and cirrhotic tissues indicated that the nonlinearity parameter does not depend strongly on pathology. However, the values for fixed tissues were somewhat higher than those of the fresh tissues.

  3. Association between bibliometric parameters, reporting and methodological quality of randomised controlled trials in vascular and endovascular surgery.

    PubMed

    Hajibandeh, Shahab; Hajibandeh, Shahin; Antoniou, George A; Green, Patrick A; Maden, Michelle; Torella, Francesco

    2017-04-01

    Purpose We aimed to investigate association between bibliometric parameters, reporting and methodological quality of vascular and endovascular surgery randomised controlled trials. Methods The most recent 75 and oldest 75 randomised controlled trials published in leading journals over a 10-year period were identified. The reporting quality was analysed using the CONSORT statement, and methodological quality with the Intercollegiate Guidelines Network checklist. We used exploratory univariate and multivariable linear regression analysis to investigate associations. Findings Bibliometric parameters such as type of journal, study design reported in title, number of pages; external funding, industry sponsoring and number of citations are associated with reporting quality. Moreover, parameters such as type of journal, subject area and study design reported in title are associated with methodological quality. Conclusions The bibliometric parameters of randomised controlled trials may be independent predictors for their reporting and methodological quality. Moreover, the reporting quality of randomised controlled trials is associated with their methodological quality and vice versa.

  4. Improving the quality of parameter estimates obtained from slug tests

    USGS Publications Warehouse

    Butler, J.J.; McElwee, C.D.; Liu, W.

    1996-01-01

    The slug test is one of the most commonly used field methods for obtaining in situ estimates of hydraulic conductivity. Despite its prevalence, this method has received criticism from many quarters in the ground-water community. This criticism emphasizes the poor quality of the estimated parameters, a condition that is primarily a product of the somewhat casual approach that is often employed in slug tests. Recently, the Kansas Geological Survey (KGS) has pursued research directed it improving methods for the performance and analysis of slug tests. Based on extensive theoretical and field research, a series of guidelines have been proposed that should enable the quality of parameter estimates to be improved. The most significant of these guidelines are: (1) three or more slug tests should be performed at each well during a given test period; (2) two or more different initial displacements (Ho) should be used at each well during a test period; (3) the method used to initiate a test should enable the slug to be introduced in a near-instantaneous manner and should allow a good estimate of Ho to be obtained; (4) data-acquisition equipment that enables a large quantity of high quality data to be collected should be employed; (5) if an estimate of the storage parameter is needed, an observation well other than the test well should be employed; (6) the method chosen for analysis of the slug-test data should be appropriate for site conditions; (7) use of pre- and post-analysis plots should be an integral component of the analysis procedure, and (8) appropriate well construction parameters should be employed. Data from slug tests performed at a number of KGS field sites demonstrate the importance of these guidelines.

  5. Quality measures for nurse practitioner practice evaluation.

    PubMed

    Kleinpell, Ruth; Kapu, April N

    2017-08-01

    Evaluating the impact of nurse practitioner (NP) practice has become a priority area of focus for demonstrating outcomes. A number of quality measures are available to enable practice-specific evaluation of NP roles and initiatives. This article reviews sources of quality measures that can be used to facilitate quantifying the outcomes of NP practice as part of an overall evaluation agenda. National resources and published literature on NP quality measures were reviewed. Various resources and toolkits exist to assist NPs in identifying outcomes of practice using quality measures. The need to demonstrate outcomes of NP practice remains an ongoing priority area regardless of the clinical practice setting. A variety of sources of quality measures exist that can be used to showcase the effect of NP care. The use of quality measures can be effectively integrated into evaluation of NP role and NP-directed initiatives to demonstrate impact, and enhance the conduct of an NP outcomes assessment. The use of organizational, NP-specific, and national-related quality measures can help to showcase how NP care improves the quality, safety, and costs of health care. ©2017 American Association of Nurse Practitioners.

  6. Effects of rotor parameter variations on handling qualities of unaugmented helicopters in simulated terrain flight

    NASA Technical Reports Server (NTRS)

    Talbot, P. D.; Dugan, D. D.; Chen, R. T. N.; Gerdes, R. M.

    1980-01-01

    A coordinated analysis and ground simulator experiment was performed to investigate the effects on single rotor helicopter handling qualities of systematic variations in the main rotor hinge restraint, hub hinge offset, pitch-flap coupling, and blade lock number. Teetering rotor, articulated rotor, and hingeless rotor helicopters were evaluated by research pilots in special low level flying tasks involving obstacle avoidance at 60 to 100 knots airspeed. The results of the experiment are in the form of pilot ratings, pilot commentary, and some objective performance measures. Criteria for damping and sensitivity are reexamined when combined with the additional factors of cross coupling due to pitch and roll rates, pitch coupling with collective pitch, and longitudinal static stability. Ratings obtained with and without motion are compared. Acceptable flying qualities were obtained within each rotor type by suitable adjustment of the hub parameters, however, pure teetering rotors were found to lack control power for the tasks. A limit for the coupling parameter L sub q/L sub p of 0.35 is suggested.

  7. Associations between urinary phthalate concentrations and semen quality parameters in a general population

    PubMed Central

    Bloom, M.S.; Whitcomb, B.W.; Chen, Z.; Ye, A.; Kannan, K.; Buck Louis, G.M.

    2015-01-01

    STUDY QUESTION Are urinary phthalate concentrations associated with altered semen quality parameters among males recruited from the general population? SUMMARY ANSWER Urinary levels of metabolites of phthalate diesters are associated with lower total sperm counts, larger sperm head sizes, and higher percentages of morphologically abnormal sperm. WHAT IS KNOWN ALREADY High dose experiments in rats implicate phthalates as anti-androgens. Studies involving infertile men seeking care suggest that phthalates influence measures of semen quality raising concern about the implications for men in the general population. STUDY DESIGN, SIZE, DURATION This prospective cohort study comprised 501 male partners in couples discontinuing contraception to become pregnant, who were recruited from 16 US counties using population-based sampling frameworks from 2005 to 2009. PARTICIPANTS/MATERIALS, SETTING, METHODS Urine and semen samples were obtained at baseline from 473 (94%) men, of whom 378 (80%) men provided a second sample the following month. Urine was analyzed for 14 monoester metabolites of phthalate diesters by high-performance liquid chromatography coupled to tandem mass spectrometry. Semen samples were analyzed for 34 quality parameters categorized as general, motility, morphology, sperm head and sperm chromatin structure. MAIN RESULTS AND THE ROLE OF CHANCE Urinary mono-[2-(carboxymethyl) hexyl] phthalate (MCMHP), mono-(2-ethyl-5-hydroxyhexyl) phthalate (MEHHP), mono-benzyl phthalate (MBzP), and mono-isononyl phthalate (MNP) were significantly associated with lower total sperm counts and concentrations, larger sperm head sizes, higher proportions of megalo head sperm morphology, and/or other morphological changes. Urinary mono-methyl phthalate (MMP) and mono-cyclohexyl phthalate (MCPP) were significantly associated with lower sperm motility, and urine mono-2-ethylhexyl phthalate (MEHP) was significantly associated with higher sperm motility. LIMITATIONS, REASONS FOR

  8. Segmentation quality evaluation using region-based precision and recall measures for remote sensing images

    NASA Astrophysics Data System (ADS)

    Zhang, Xueliang; Feng, Xuezhi; Xiao, Pengfeng; He, Guangjun; Zhu, Liujun

    2015-04-01

    Segmentation of remote sensing images is a critical step in geographic object-based image analysis. Evaluating the performance of segmentation algorithms is essential to identify effective segmentation methods and optimize their parameters. In this study, we propose region-based precision and recall measures and use them to compare two image partitions for the purpose of evaluating segmentation quality. The two measures are calculated based on region overlapping and presented as a point or a curve in a precision-recall space, which can indicate segmentation quality in both geometric and arithmetic respects. Furthermore, the precision and recall measures are combined by using four different methods. We examine and compare the effectiveness of the combined indicators through geometric illustration, in an effort to reveal segmentation quality clearly and capture the trade-off between the two measures. In the experiments, we adopted the multiresolution segmentation (MRS) method for evaluation. The proposed measures are compared with four existing discrepancy measures to further confirm their capabilities. Finally, we suggest using a combination of the region-based precision-recall curve and the F-measure for supervised segmentation evaluation.

  9. An Analysis of FM Jamming and Noise Quality Measures

    DTIC Science & Technology

    1993-12-01

    equipment setup is shown in figure 6. For reasons of practicality and manageability , all equipment was chosen to be commercially available and of a fairly...bins based on the size of the parameter F. It computes a smoothed "Turner Noise Qaulity " similar to the noise quality measure employed by Daly in his...recý.orate for :nf-,aton Doe,A-,ým5 1o- A c-t•s. )2 15 efferso Oarts H,9gPay, Srte 1204. ArtOngton, VA 222024302 and to the Of"ce of Management and aucige

  10. Measuring the quality of life in hypertension according to Item Response Theory

    PubMed Central

    Borges, José Wicto Pereira; Moreira, Thereza Maria Magalhães; Schmitt, Jeovani; de Andrade, Dalton Francisco; Barbetta, Pedro Alberto; de Souza, Ana Célia Caetano; Lima, Daniele Braz da Silva; Carvalho, Irialda Saboia

    2017-01-01

    ABSTRACT OBJECTIVE To analyze the Miniquestionário de Qualidade de Vida em Hipertensão Arterial (MINICHAL – Mini-questionnaire of Quality of Life in Hypertension) using the Item Response Theory. METHODS This is an analytical study conducted with 712 persons with hypertension treated in thirteen primary health care units of Fortaleza, State of Ceará, Brazil, in 2015. The steps of the analysis by the Item Response Theory were: evaluation of dimensionality, estimation of parameters of items, and construction of scale. The study of dimensionality was carried out on the polychoric correlation matrix and confirmatory factor analysis. To estimate the item parameters, we used the Gradual Response Model of Samejima. The analyses were conducted using the free software R with the aid of psych and mirt. RESULTS The analysis has allowed the visualization of item parameters and their individual contributions in the measurement of the latent trait, generating more information and allowing the construction of a scale with an interpretative model that demonstrates the evolution of the worsening of the quality of life in five levels. Regarding the item parameters, the items related to the somatic state have had a good performance, as they have presented better power to discriminate individuals with worse quality of life. The items related to mental state have been those which contributed with less psychometric data in the MINICHAL. CONCLUSIONS We conclude that the instrument is suitable for the identification of the worsening of the quality of life in hypertension. The analysis of the MINICHAL using the Item Response Theory has allowed us to identify new sides of this instrument that have not yet been addressed in previous studies. PMID:28492764

  11. Semen quality in Peruvian pesticide applicators: association between urinary organophosphate metabolites and semen parameters

    PubMed Central

    Yucra, Sandra; Gasco, Manuel; Rubio, Julio; Gonzales, Gustavo F

    2008-01-01

    Background Organophosphates are broad class of chemicals widely used as pesticides throughout the world. We performed a cross-sectional study of associations between dialkylphosphate metabolites of organophosphates and semen quality among pesticide applicators in Majes (Arequipa), Peru. Methods Thirty-one men exposed to organophosphate (OP) pesticides and 31 non-exposed were recruited (age, 20–60 years). In exposed subjects, semen and a blood sample were obtained one day after the last pesticide application. Subjects were grouped according to levels of OP metabolites in urine. Semen samples were analyzed for sperm concentration, percentage of sperm motility, percentage of normal morphology, semen leucocytes and concentrations of fructose and zinc. Exposure to OP was assessed by measuring six urinary OP metabolites (dimethyl and diethyl phosphates and thiophosphates) by gas chromatography using a single flame photometric detector. Results Diethyldithiophosphate (p = 0.04) and diethylthiophosphate (p = 0.02) better reflected occupational pesticide exposure than other OP metabolites. Semen analysis revealed a significant reduction of semen volume and an increase in semen pH in men with OP metabolites. Multiple regression analysis showed that both occupational exposure to pesticides and the time of exposure to pesticides were more closely related to alterations in semen quality parameters than the single measurement of OP metabolites in urine. Conclusion The study demonstrated that occupational exposure to OP pesticides was more closely related to alterations in semen quality than a single measurement of urine OP metabolites. Current measurement of OP metabolites in urine may not reflect the full risk. PMID:19014632

  12. Measuring Inpatient Rehabilitation Facility Quality of Care: Discharge Self-Care Functional Status Quality Measure.

    PubMed

    Pardasaney, Poonam K; Deutsch, Anne; Iriondo-Perez, Jeniffer; Ingber, Melvin J; McMullen, Tara

    2018-06-01

    To describe the calculation and psychometric properties of the discharge self-care functional status quality measure implemented in the Centers for Medicare & Medicaid Services' (CMS) Inpatient Rehabilitation Facility (IRF) Quality Reporting Program on October 1, 2016. Medicare fee-for-service (FFS) patients from 38 IRFs that participated in the CMS Post-Acute Care Payment Reform Demonstration were included in this cohort study. Data came from the Continuity Assessment Record and Evaluation Item Set, IRF-Patient Assessment Instrument, and Medicare claims. For each patient, we calculated an expected discharge self-care score, risk-adjusted for demographic and baseline clinical characteristics. The performance score of each IRF equaled the percentage of patient stays where the observed discharge self-care score met or exceeded the expected score. We assessed the measure's discriminatory ability across IRFs and reliability. IRFs. Medicare FFS patients aged ≥21 years (N=4769). Not applicable. Facility-level discharge self-care quality measure performance score. A total of 4769 patient stays were included; 57% of stays were in women, and 12.1% were in patients aged <65 years. Stroke was the most common diagnosis (21.8%). The mean±SD performance score was 55.1%±16.6% (range, 25.8%-100%). About 54% of IRFs had scores significantly different from the percentage of stays that met or exceeded the expected discharge self-care score in the overall demonstration sample. The quality measure showed strong reliability, with intraclass correlation coefficients of .91. The discharge self-care quality measure showed strong discriminatory ability and reliability, representing an important initial step in evaluation of IRF self-care outcomes. A wide range in performance scores suggested a gap in quality of care across IRFs. Future work should include testing the measure with nationwide data from all IRFs. Published by Elsevier Inc.

  13. Quality Measures for Hospice and Palliative Care: Piloting the PEACE Measures

    PubMed Central

    Rokoske, Franziska S.; Durham, Danielle; Cagle, John G.; Hanson, Laura C.

    2014-01-01

    Abstract Background: The Carolinas Center for Medical Excellence launched the PEACE project in 2006, under contract with the Centers for Medicare & Medicaid Services (CMS), to identify, develop, and pilot test quality measures for hospice and palliative care programs. Objectives: The project collected pilot data to test the usability and feasibility of potential quality measures and data collection processes for hospice and palliative care programs. Settings/subjects: Twenty-two hospices participating in a national Quality Improvement Collaborative (QIC) submitted data from 367 chart reviews for pain care and 45 chart reviews for nausea care. Fourteen additional hospices completed a one-time data submission of 126 chart reviews on 60 potential patient-level quality measures across eight domains of care and an organizational assessment evaluating structure and processes of care. Design: Usability was assessed by examining the range, variability and size of the populations targeted by each quality measure. Feasibility was assessed during the second pilot study by surveying data abstractors about the abstraction process and examining the rates of missing data. The impact of data collection processes was assessed by comparing results obtained using different processes. Results: Measures shown to be both usable and feasible included: screening for physical symptoms on admission and documentation of treatment preferences. Methods of data collection and measure construction appear to influence observed rates of quality of care. Conclusions: We successfully identified quality measures with potential for use in hospices and palliative care programs. Future research is needed to understand whether these measures are sensitive to quality improvement interventions. PMID:24921162

  14. Quality Assurance of Chemical Measurements.

    ERIC Educational Resources Information Center

    Taylor, John K.

    1981-01-01

    Reviews aspects of quality control (methods to control errors) and quality assessment (verification that systems are operating within acceptable limits) including an analytical measurement system, quality control by inspection, control charts, systematic errors, and use of SRMs, materials for which properties are certified by the National Bureau…

  15. [Quality measurement using administrative data in mandatory quality assurance].

    PubMed

    Heller, Günther; Szecsenyi, Joachim; Willms, Gerald; Broge, Björn

    2014-01-01

    For several years, the use of administrative data in mandatory quality measurement has been requested by several stakeholders in Germany. Main advantages of using administrative data include the reduction of documentary expenditures and the possibility to perform longitudinal quality analyses across different healthcare units. After a short introduction, a brief overview of the current use of administrative data for mandatory quality assurance as well as current developments is given, which will then be further exemplified by decubital ulcer prophylaxis. By using administrative data coding expenditures in this clinical area could be reduced by nine million data fields. At the same time the population analysed was expanded resulting in a more than tenfold increase in potentially quality-relevant events. Finally, perspectives, further developments, possibilities as well as limits of quality measurement with administrative data are discussed. Copyright © 2014. Published by Elsevier GmbH.

  16. Approaches in fostering quality parameters for medicinal botanicals in the Indian context.

    PubMed

    Gupta, Pooja D; Daswani, Poonam G; Birdi, Tannaz J

    2014-01-01

    India is among the important megabiodiversity centers of the world with nearly 45,000 known plant species. This diversity coupled with a rich heritage of traditional knowledge has made India a home to several important time-honored systems of health care such as Ayurveda, Siddha and Unani. Herbal medicines, however, are associated with a number of shortcomings including uniform efficacy and lack of appropriate quality control measures at various stages of product development. The review intends to outline the importance of fostering quality parameters towards standardization and manufacturing of botanicals for India to emerge as a leader in global market of herbal products. Literature survey was carried out on important parameters for processing and manufacturing of botanicals. The review highlights that there have been constant efforts for developing state of the art technologies in the field of herbal research. It also reflects that Government authorities have also taken a number of initiatives to formulate appropriate guidelines from standardization of raw materials to obtaining botanical products. However, in the Indian context, there exist certain lacunae in the current regulatory mechanisms which need to be strengthened and stringently implemented to ensure safety, purity and efficacy of herbal medicines. Towards this the approaches being developed globally can be adopted. Based on the literature reviewed, in our opinion, four areas viz., benefit sharing, investment by industry, standardization and national/international networking structure need immediate attention for strengthening Traditional Systems of Medicine in India.

  17. Rural relevant quality measures for critical access hospitals.

    PubMed

    Casey, Michelle M; Moscovice, Ira; Klingner, Jill; Prasad, Shailendra

    2013-01-01

    To identify current and future relevant quality measures for Critical Access Hospitals (CAHs). Three criteria (patient volume, internal usefulness for quality improvement, and external usefulness for public reporting and payment reform) were used to analyze quality measures for their relevance for CAHs. A 6-member panel with expertise in rural hospital quality measurement and improvement provided input regarding the final measure selection. The relevant quality measures for CAHs include measures that are ready for reporting now and measures that need specifications to be finalized and/or a data reporting mechanism to be established. They include inpatient measures for specific medical conditions, global measures that address appropriate care across multiple medical conditions, and Emergency Department measures. All CAHs should publicly report on relevant quality measures. Acceptance of a single consolidated set of quality measures with common specifications for CAHs by all entities involved in regulation, accreditation, and payment; a phased process to implement the relevant measures; and the provision of technical assistance would help CAHs meet the challenge of reporting. © 2012 National Rural Health Association.

  18. EFFECTS OF AROMATHERAPY MASSAGE ON THE SLEEP QUALITY AND PHYSIOLOGICAL PARAMETERS OF PATIENTS IN A SURGICAL INTENSIVE CARE UNIT

    PubMed Central

    Özlü, Zeynep Karaman; Bilican, Pınar

    2017-01-01

    Background: Surgical pain is experienced by inpatients with clinical, disease-related concerns, unknown encounters after surgery, quality of sleep, restrictions in position after surgery is known to be serious. The study was conducted to determine the effect of aromatherapy massage on quality of sleep and physiological parameters in surgical intensive care patients. Materials and Methods: This is an experimental study. The sample of this study consisted of 60 patients who were divided into two groups as experimental group and control group including 30 patients in each one. The participants were postoperative patients, absent complications, who were unconscious and extubated. A data collection form on personal characteristics of the patients, a registration form on their physical parameters and the Richards-Campbell Sleep Scale (RCSQ) were used to collect the data of the study. Results: The Richards-Campbell Sleep Scale indicated that while the experimental group had a mean score of 53.80 ± 13.20, the control group had a mean score of 29.08 ± 9.71 and there was a statistically significant difference between mean scores of the groups. In a comparison of physiologic parameters, only diastolic blood pressure measuring between parameters in favor of an assembly as a statistically significant difference was detected. Conclusions: Results of the study showed that aromatherapy massage enhanced the sleep quality of patients in a surgical intensive care unit and resulted in some positive changes in their physiological parameters. PMID:28480419

  19. Using collective expert judgements to evaluate quality measures of mass spectrometry images.

    PubMed

    Palmer, Andrew; Ovchinnikova, Ekaterina; Thuné, Mikael; Lavigne, Régis; Guével, Blandine; Dyatlov, Andrey; Vitek, Olga; Pineau, Charles; Borén, Mats; Alexandrov, Theodore

    2015-06-15

    Imaging mass spectrometry (IMS) is a maturating technique of molecular imaging. Confidence in the reproducible quality of IMS data is essential for its integration into routine use. However, the predominant method for assessing quality is visual examination, a time consuming, unstandardized and non-scalable approach. So far, the problem of assessing the quality has only been marginally addressed and existing measures do not account for the spatial information of IMS data. Importantly, no approach exists for unbiased evaluation of potential quality measures. We propose a novel approach for evaluating potential measures by creating a gold-standard set using collective expert judgements upon which we evaluated image-based measures. To produce a gold standard, we engaged 80 IMS experts, each to rate the relative quality between 52 pairs of ion images from MALDI-TOF IMS datasets of rat brain coronal sections. Experts' optional feedback on their expertise, the task and the survey showed that (i) they had diverse backgrounds and sufficient expertise, (ii) the task was properly understood, and (iii) the survey was comprehensible. A moderate inter-rater agreement was achieved with Krippendorff's alpha of 0.5. A gold-standard set of 634 pairs of images with accompanying ratings was constructed and showed a high agreement of 0.85. Eight families of potential measures with a range of parameters and statistical descriptors, giving 143 in total, were evaluated. Both signal-to-noise and spatial chaos-based measures performed highly with a correlation of 0.7 to 0.9 with the gold standard ratings. Moreover, we showed that a composite measure with the linear coefficients (trained on the gold standard with regularized least squares optimization and lasso) showed a strong linear correlation of 0.94 and an accuracy of 0.98 in predicting which image in a pair was of higher quality. The anonymized data collected from the survey and the Matlab source code for data processing can be found

  20. Using collective expert judgements to evaluate quality measures of mass spectrometry images

    PubMed Central

    Palmer, Andrew; Ovchinnikova, Ekaterina; Thuné, Mikael; Lavigne, Régis; Guével, Blandine; Dyatlov, Andrey; Vitek, Olga; Pineau, Charles; Borén, Mats; Alexandrov, Theodore

    2015-01-01

    Motivation: Imaging mass spectrometry (IMS) is a maturating technique of molecular imaging. Confidence in the reproducible quality of IMS data is essential for its integration into routine use. However, the predominant method for assessing quality is visual examination, a time consuming, unstandardized and non-scalable approach. So far, the problem of assessing the quality has only been marginally addressed and existing measures do not account for the spatial information of IMS data. Importantly, no approach exists for unbiased evaluation of potential quality measures. Results: We propose a novel approach for evaluating potential measures by creating a gold-standard set using collective expert judgements upon which we evaluated image-based measures. To produce a gold standard, we engaged 80 IMS experts, each to rate the relative quality between 52 pairs of ion images from MALDI-TOF IMS datasets of rat brain coronal sections. Experts’ optional feedback on their expertise, the task and the survey showed that (i) they had diverse backgrounds and sufficient expertise, (ii) the task was properly understood, and (iii) the survey was comprehensible. A moderate inter-rater agreement was achieved with Krippendorff’s alpha of 0.5. A gold-standard set of 634 pairs of images with accompanying ratings was constructed and showed a high agreement of 0.85. Eight families of potential measures with a range of parameters and statistical descriptors, giving 143 in total, were evaluated. Both signal-to-noise and spatial chaos-based measures performed highly with a correlation of 0.7 to 0.9 with the gold standard ratings. Moreover, we showed that a composite measure with the linear coefficients (trained on the gold standard with regularized least squares optimization and lasso) showed a strong linear correlation of 0.94 and an accuracy of 0.98 in predicting which image in a pair was of higher quality. Availability and implementation: The anonymized data collected from the survey

  1. Development of Fast Response In-situ Sensors for Simultaneous Measurements of Seawater Carbon Dioxide Parameters

    NASA Astrophysics Data System (ADS)

    Wang, A. Z.; Sonnichsen, F. N.; Chu, S. N.; Bradley, A. M.; Hoering, K.

    2016-02-01

    The marine CO2 (inorganic carbon) system is characterized by four primary parameters - total dissolved inorganic carbon (DIC), total alkalinity (TA), partial pressure of CO2 (pCO2), and pH. These parameters are central to the study of the marine carbon cycle and ocean acidification. Simultaneous measurements of two of the four CO2 parameters are required to fully resolve the seawater CO2 system, and DIC is one of the preferred parameters. A self-calibrating, in-situ sensor, Channelized Optical System (CHANOS), has recently been developed to provide simultaneous measurements of both DIC and pH, resolving carbonate chemistry with a single system. CHANOS is among the first to achieve simultaneous, in-situ measurements of a desired pair of CO2 parameters. DIC and pH channels both use flow-through, spectrophotometric methods to detect relative absorbances of the acid and base forms of a pH-sensitive indicator. The precision of CHANOS in laboratory and in-situ tests are ±0.002 and ±3.0 µmol kg-1 for pH and DIC, respectively. In-situ comparison with bottle sampling and analyses indicate that the accuracies for pH and DIC are ±0.004 and ±5.0 µmol kg-1, respectively. It has been demonstrated that CHANOS can make in-situ, climatology-quality measurements to resolve the CO2 system in dynamic aquatic environments. To further improve response time of the sensor, especially for DIC measurements, a new generation of CHANOS-DIC is under development. The new system adapts the recently developed spectrophotometric DIC method to achieve flow-through CO2 equilibration between an acidified sample and an indicator solution with a response time as fast as 22s. Continuous measurements are also achievable. Because of the fast response of CHANOS measurements, it is versatile and suitable for deployments on both fixed (e.g. buoys) and mobile (e.g., AUV, ROV, and profilers) platforms.

  2. Identifyability measures to select the parameters to be estimated in a solid-state fermentation distributed parameter model.

    PubMed

    da Silveira, Christian L; Mazutti, Marcio A; Salau, Nina P G

    2016-07-08

    Process modeling can lead to of advantages such as helping in process control, reducing process costs and product quality improvement. This work proposes a solid-state fermentation distributed parameter model composed by seven differential equations with seventeen parameters to represent the process. Also, parameters estimation with a parameters identifyability analysis (PIA) is performed to build an accurate model with optimum parameters. Statistical tests were made to verify the model accuracy with the estimated parameters considering different assumptions. The results have shown that the model assuming substrate inhibition better represents the process. It was also shown that eight from the seventeen original model parameters were nonidentifiable and better results were obtained with the removal of these parameters from the estimation procedure. Therefore, PIA can be useful to estimation procedure, since it may reduce the number of parameters that can be evaluated. Further, PIA improved the model results, showing to be an important procedure to be taken. © 2016 American Institute of Chemical Engineers Biotechnol. Prog., 32:905-917, 2016. © 2016 American Institute of Chemical Engineers.

  3. Quality measurement and improvement in liver transplantation.

    PubMed

    Mathur, Amit K; Talwalkar, Jayant

    2018-06-01

    There is growing interest in the quality of health care delivery in liver transplantation. Multiple stakeholders, including patients, transplant providers and their hospitals, payers, and regulatory bodies have an interest in measuring and monitoring quality in the liver transplant process, and understanding differences in quality across centres. This article aims to provide an overview of quality measurement and regulatory issues in liver transplantation performed within the United States. We review how broader definitions of health care quality should be applied to liver transplant care models. We outline the status quo including the current regulatory agencies, public reporting mechanisms, and requirements around quality assurance and performance improvement (QAPI) activities. Additionally, we further discuss unintended consequences and opportunities for growth in quality measurement. Quality measurement and the integration of quality improvement strategies into liver transplant programmes hold significant promise, but multiple challenges to successful implementation must be addressed to optimise value. Copyright © 2018 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  4. Consideration of rainwater quality parameters for drinking purposes: A case study in rural Vietnam.

    PubMed

    Lee, Minju; Kim, Mikyeong; Kim, Yonghwan; Han, Mooyoung

    2017-09-15

    Rainwater, which is used for drinking purposes near Hanoi, Vietnam, was analysed for water quality based on 1.5 years of monitoring data. In total, 23 samples were collected from different points within two rainwater harvesting systems (RWHSs). Most parameters met the standard except micro-organisms. Coliform and Escherichia coli (E. coli) were detected when the rainwater was not treated with ultraviolet (UV) light; however, analysis of rainwater after UV sterilisation showed no trace of micro-organisms. The RWHSs appear to provide drinking water of relatively good quality compared with surface water and groundwater. The superior quality of the rainwater suggests the necessity for new drinking rainwater standards because applying all of the drinking water quality standards to rainwater is highly inefficient. The traditionally implemented standards could cause more difficulties for developing countries using RWHSs installed decentralized as a source of drinking water, particularly in areas not well supplied with testing equipment, because such countries must bear the expense and time for these measures. This paper proposes the necessity of rainwater quality guideline, which could serve as a safe and cost-effective alternative to provide an access to safe drinking water. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Physicochemical parameters affecting the perception of borehole water quality in Ghana.

    PubMed

    Kulinkina, Alexandra V; Plummer, Jeanine D; Chui, Kenneth K H; Kosinski, Karen C; Adomako-Adjei, Theodora; Egorov, Andrey I; Naumova, Elena N

    2017-08-01

    Rural Ghanaian communities continue using microbiologically contaminated surface water sources due in part to undesirable organoleptic characteristics of groundwater from boreholes. Our objective was to identify thresholds of physical and chemical parameters associated with consumer complaints related to groundwater. Water samples from 94 boreholes in the dry season and 68 boreholes in the rainy season were analyzed for 18 parameters. Interviews of consumers were conducted at each borehole regarding five commonly expressed water quality problems (salty taste, presence of particles, unfavorable scent, oily sheen formation on the water surface, and staining of starchy foods during cooking). Threshold levels of water quality parameters predictive of complaints were determined using the Youden index maximizing the sum of sensitivity and specificity. The probability of complaints at various parameter concentrations was estimated using logistic regression. Exceedances of WHO guidelines were detected for pH, turbidity, chloride, iron, and manganese. Concentrations of total dissolved solids (TDS) above 172mg/L were associated with salty taste complaints. Although the WHO guideline is 1000mg/L, even at half the guideline, the likelihood of salty taste complaint was 75%. Iron concentrations above 0.11, 0.14 and 0.43mg/L (WHO guideline value 0.3mg/L) were associated with complaints of unfavorable scent, oily sheen, and food staining, respectively. Iron and TDS concentrations exhibited strong spatial clustering associated with specific geological formations. Improved groundwater sources in rural African communities that technically meet WHO water quality guidelines may be underutilized in preference of unimproved sources for drinking and domestic uses, compromising human health and sustainability of improved water infrastructure. Copyright © 2017 Elsevier GmbH. All rights reserved.

  6. Quality Measures in Orthopaedic Sports Medicine: A Systematic Review.

    PubMed

    Abrams, Geoffrey D; Greenberg, Daniel R; Dragoo, Jason L; Safran, Marc R; Kamal, Robin N

    2017-10-01

    To report the current quality measures that are applicable to orthopaedic sports medicine physicians. Six databases were searched with a customized search term to identify quality measures relevant to orthopaedic sports medicine surgeons: MEDLINE/PubMed, EMBASE, the National Quality Forum (NQF) Quality Positioning System (QPS), the Agency for Healthcare Research and Quality (AHRQ) National Quality Measures Clearinghouse (NQMC), the Physician Quality Reporting System (PQRS) database, and the American Academy of Orthopaedic Surgeons (AAOS) website. Results were screened by 2 Board-certified orthopaedic surgeons with fellowship training in sports medicine and dichotomized based on sports medicine-specific or general orthopaedic (nonarthroplasty) categories. Hip and knee arthroplasty measures were excluded. Included quality measures were further categorized based on Donabedian's domains and the Center for Medicare and Medicaid (CMS) National Quality Strategy priorities. A total of 1,292 quality measures were screened and 66 unique quality measures were included. A total of 47 were sports medicine-specific and 19 related to the general practice of orthopaedics for a fellowship-trained sports medicine specialist. Nineteen (29%) quality measures were collected within PQRS, with 5 of them relating to sports medicine and 14 relating to general orthopaedics. AAOS Clinical Practice Guidelines (CPGs) comprised 40 (60%) of the included measures and were all within sports medicine. Five (8%) additional measures were collected within AHRQ and 2 (3%) within NQF. Most quality measures consist of process rather than outcome or structural measures. No measures addressing concussions were identified. There are many existing quality measures relating to the practice of orthopaedic sports medicine. Most quality measures are process measures described within PQRS or AAOS CPGs. Knowledge of quality measures are important as they may be used to improve care, are increasingly being used to

  7. Measurement methods and accuracy analysis of Chang'E-5 Panoramic Camera installation parameters

    NASA Astrophysics Data System (ADS)

    Yan, Wei; Ren, Xin; Liu, Jianjun; Tan, Xu; Wang, Wenrui; Chen, Wangli; Zhang, Xiaoxia; Li, Chunlai

    2016-04-01

    Chang'E-5 (CE-5) is a lunar probe for the third phase of China Lunar Exploration Project (CLEP), whose main scientific objectives are to implement lunar surface sampling and to return the samples back to the Earth. To achieve these goals, investigation of lunar surface topography and geological structure within sampling area seems to be extremely important. The Panoramic Camera (PCAM) is one of the payloads mounted on CE-5 lander. It consists of two optical systems which installed on a camera rotating platform. Optical images of sampling area can be obtained by PCAM in the form of a two-dimensional image and a stereo images pair can be formed by left and right PCAM images. Then lunar terrain can be reconstructed based on photogrammetry. Installation parameters of PCAM with respect to CE-5 lander are critical for the calculation of exterior orientation elements (EO) of PCAM images, which is used for lunar terrain reconstruction. In this paper, types of PCAM installation parameters and coordinate systems involved are defined. Measurement methods combining camera images and optical coordinate observations are studied for this work. Then research contents such as observation program and specific solution methods of installation parameters are introduced. Parametric solution accuracy is analyzed according to observations obtained by PCAM scientifically validated experiment, which is used to test the authenticity of PCAM detection process, ground data processing methods, product quality and so on. Analysis results show that the accuracy of the installation parameters affects the positional accuracy of corresponding image points of PCAM stereo images within 1 pixel. So the measurement methods and parameter accuracy studied in this paper meet the needs of engineering and scientific applications. Keywords: Chang'E-5 Mission; Panoramic Camera; Installation Parameters; Total Station; Coordinate Conversion

  8. DRAINMOD-GIS: a lumped parameter watershed scale drainage and water quality model

    Treesearch

    G.P. Fernandez; G.M. Chescheir; R.W. Skaggs; D.M. Amatya

    2006-01-01

    A watershed scale lumped parameter hydrology and water quality model that includes an uncertainty analysis component was developed and tested on a lower coastal plain watershed in North Carolina. Uncertainty analysis was used to determine the impacts of uncertainty in field and network parameters of the model on the predicted outflows and nitrate-nitrogen loads at the...

  9. Quality Assessment Parameters for Student Support at Higher Education Institutions

    ERIC Educational Resources Information Center

    Sajiene, Laima; Tamuliene, Rasa

    2012-01-01

    The research presented in this article aims to validate quality assessment parameters for student support at higher education institutions. Student support is discussed as the system of services provided by a higher education institution which helps to develop student-centred curriculum and fulfils students' emotional, academic, social needs, and…

  10. Impact of initial surface parameters on the final quality of laser micro-polished surfaces

    NASA Astrophysics Data System (ADS)

    Chow, Michael; Bordatchev, Evgueni V.; Knopf, George K.

    2012-03-01

    Laser micro-polishing (LμP) is a new laser-based microfabrication technology for improving surface quality during a finishing operation and for producing parts and surfaces with near-optical surface quality. The LμP process uses low power laser energy to melt a thin layer of material on the previously machined surface. The polishing effect is achieved as the molten material in the laser-material interaction zone flows from the elevated regions to the local minimum due to surface tension. This flow of molten material then forms a thin ultra-smooth layer on the top surface. The LμP is a complex thermo-dynamic process where the melting, flow and redistribution of molten material is significantly influenced by a variety of process parameters related to the laser, the travel motions and the material. The goal of this study is to analyze the impact of initial surface parameters on the final surface quality. Ball-end micromilling was used for preparing initial surface of samples from H13 tool steel that were polished using a Q-switched Nd:YAG laser. The height and width of micromilled scallops (waviness) were identified as dominant parameter affecting the quality of the LμPed surface. By adjusting process parameters, the Ra value of a surface, having a waviness period of 33 μm and a peak-to-valley value of 5.9 μm, was reduced from 499 nm to 301 nm, improving the final surface quality by 39.7%.

  11. An Illustration of Determining Quantitatively the Rock Mass Quality Parameters of the Hoek-Brown Failure Criterion

    NASA Astrophysics Data System (ADS)

    Wu, Li; Adoko, Amoussou Coffi; Li, Bo

    2018-04-01

    In tunneling, determining quantitatively the rock mass strength parameters of the Hoek-Brown (HB) failure criterion is useful since it can improve the reliability of the design of tunnel support systems. In this study, a quantitative method is proposed to determine the rock mass quality parameters of the HB failure criterion, namely the Geological Strength Index (GSI) and the disturbance factor ( D) based on the structure of drilling core and weathering condition of rock mass combined with acoustic wave test to calculate the strength of rock mass. The Rock Mass Structure Index and the Rock Mass Weathering Index are used to quantify the GSI while the longitudinal wave velocity ( V p) is employed to derive the value of D. The DK383+338 tunnel face of Yaojia tunnel of Shanghai-Kunming passenger dedicated line served as illustration of how the methodology is implemented. The values of the GSI and D are obtained using the HB criterion and then using the proposed method. The measured in situ stress is used to evaluate their accuracy. To this end, the major and minor principal stresses are calculated based on the GSI and D given by HB criterion and the proposed method. The results indicated that both methods were close to the field observation which suggests that the proposed method can be used for determining quantitatively the rock quality parameters, as well. However, these results remain valid only for rock mass quality and rock type similar to those of the DK383+338 tunnel face of Yaojia tunnel.

  12. Taguchi's off line method and Multivariate loss function approach for quality management and optimization of process parameters -A review

    NASA Astrophysics Data System (ADS)

    Bharti, P. K.; Khan, M. I.; Singh, Harbinder

    2010-10-01

    Off-line quality control is considered to be an effective approach to improve product quality at a relatively low cost. The Taguchi method is one of the conventional approaches for this purpose. Through this approach, engineers can determine a feasible combination of design parameters such that the variability of a product's response can be reduced and the mean is close to the desired target. The traditional Taguchi method was focused on ensuring good performance at the parameter design stage with one quality characteristic, but most products and processes have multiple quality characteristics. The optimal parameter design minimizes the total quality loss for multiple quality characteristics. Several studies have presented approaches addressing multiple quality characteristics. Most of these papers were concerned with maximizing the parameter combination of signal to noise (SN) ratios. The results reveal the advantages of this approach are that the optimal parameter design is the same as the traditional Taguchi method for the single quality characteristic; the optimal design maximizes the amount of reduction of total quality loss for multiple quality characteristics. This paper presents a literature review on solving multi-response problems in the Taguchi method and its successful implementation in various industries.

  13. Objective measurement of the optical image quality in the human eye

    NASA Astrophysics Data System (ADS)

    Navarro, Rafael M.

    2001-05-01

    This communication reviews some recent studies on the optical performance of the human eye. Although the retinal image cannot be recorded directly, different objective methods have been developed, which permit to determine optical quality parameters, such as the Point Spread Function (PSF), the Modulation Transfer Function (MTF), the geometrical ray aberrations or the wavefront distortions, in the living human eye. These methods have been applied in both basic and applied research. This includes the measurement of the optical performance of the eye across visual field, the optical quality of eyes with intraocular lens implants, the aberrations induced by LASIK refractive surgery, or the manufacture of customized phase plates to compensate the wavefront aberration in the eye.

  14. Selection of noisy measurement locations for error reduction in static parameter identification

    NASA Astrophysics Data System (ADS)

    Sanayei, Masoud; Onipede, Oladipo; Babu, Suresh R.

    1992-09-01

    An incomplete set of noisy static force and displacement measurements is used for parameter identification of structures at the element level. Measurement location and the level of accuracy in the measured data can drastically affect the accuracy of the identified parameters. A heuristic method is presented to select a limited number of degrees of freedom (DOF) to perform a successful parameter identification and to reduce the impact of measurement errors on the identified parameters. This pretest simulation uses an error sensitivity analysis to determine the effect of measurement errors on the parameter estimates. The selected DOF can be used for nondestructive testing and health monitoring of structures. Two numerical examples, one for a truss and one for a frame, are presented to demonstrate that using the measurements at the selected subset of DOF can limit the error in the parameter estimates.

  15. Monitoring green leaf tea quality parameters of different TV clones grown in northeast India using satellite data.

    PubMed

    Dutta, Rishiraj

    2013-08-15

    This study tries to quantify the effects of green leaf tea parameters that influence tea quality in Northeast India. The study is to identify the different parameters that have a significant influence on tea quality through the use of remote sensing. It investigates the methods for estimating tea quality based on remotely sensed Normalized Difference Vegetation Index (NDVI) data. Attention focused on high yielding TV clones (TV1, TV18, TV22, TV23, TV25 and TV26). NDVI was obtained from ASTER images. Statistical analysis shows that NDVI has a strong significant effect on the caffeine content followed by epicatechin (EC), epigallocatechin (EGC) and to some extent in other chemical parameters. Relationships therefore exist between quality parameters and remote sensing in particular for the TV clones. This leads to the conclusion that NDVI has a large potential to be used for monitoring tea quality of individual cultivars in the future. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. An Innovative Software Tool Suite for Power Plant Model Validation and Parameter Calibration using PMU Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Yuanyuan; Diao, Ruisheng; Huang, Renke

    Maintaining good quality of power plant stability models is of critical importance to ensure the secure and economic operation and planning of today’s power grid with its increasing stochastic and dynamic behavior. According to North American Electric Reliability (NERC) standards, all generators in North America with capacities larger than 10 MVA are required to validate their models every five years. Validation is quite costly and can significantly affect the revenue of generator owners, because the traditional staged testing requires generators to be taken offline. Over the past few years, validating and calibrating parameters using online measurements including phasor measurement unitsmore » (PMUs) and digital fault recorders (DFRs) has been proven to be a cost-effective approach. In this paper, an innovative open-source tool suite is presented for validating power plant models using PPMV tool, identifying bad parameters with trajectory sensitivity analysis, and finally calibrating parameters using an ensemble Kalman filter (EnKF) based algorithm. The architectural design and the detailed procedures to run the tool suite are presented, with results of test on a realistic hydro power plant using PMU measurements for 12 different events. The calibrated parameters of machine, exciter, governor and PSS models demonstrate much better performance than the original models for all the events and show the robustness of the proposed calibration algorithm.« less

  17. Outcome quality of in-patient cardiac rehabilitation in elderly patients--identification of relevant parameters.

    PubMed

    Salzwedel, Annett; Nosper, Manfred; Röhrig, Bernd; Linck-Eleftheriadis, Sigrid; Strandt, Gert; Völler, Heinz

    2014-02-01

    Outcome quality management requires the consecutive registration of defined variables. The aim was to identify relevant parameters in order to objectively assess the in-patient rehabilitation outcome. From February 2009 to June 2010 1253 patients (70.9 ± 7.0 years, 78.1% men) at 12 rehabilitation clinics were enrolled. Items concerning sociodemographic data, the impairment group (surgery, conservative/interventional treatment), cardiovascular risk factors, structural and functional parameters and subjective health were tested in respect of their measurability, sensitivity to change and their propensity to be influenced by rehabilitation. The majority of patients (61.1%) were referred for rehabilitation after cardiac surgery, 38.9% after conservative or interventional treatment for an acute coronary syndrome. Functionally relevant comorbidities were seen in 49.2% (diabetes mellitus, stroke, peripheral artery disease, chronic obstructive lung disease). In three key areas 13 parameters were identified as being sensitive to change and subject to modification by rehabilitation: cardiovascular risk factors (blood pressure, low-density lipoprotein cholesterol, triglycerides), exercise capacity (resting heart rate, maximal exercise capacity, maximal walking distance, heart failure, angina pectoris) and subjective health (IRES-24 (indicators of rehabilitation status): pain, somatic health, psychological well-being and depression as well as anxiety on the Hospital Anxiety and Depression Scale). The outcome of in-patient rehabilitation in elderly patients can be comprehensively assessed by the identification of appropriate key areas, that is, cardiovascular risk factors, exercise capacity and subjective health. This may well serve as a benchmark for internal and external quality management.

  18. Correlations of water quality parameters with mutagenicity of chlorinated drinking water samples.

    PubMed

    Schenck, Kathleen M; Sivaganesan, Mano; Rice, Glenn E

    2009-01-01

    Adverse health effects that may result from chronic exposure to mixtures of disinfection by-products (DBPs) present in drinking waters may be linked to both the types and concentrations of DBPs present. Depending on the characteristics of the source water and treatment processes used, both types and concentrations of DBPs found in drinking waters vary substantially. The composition of a drinking-water mixture also may change during distribution. This study evaluated the relationships between mutagenicity, using the Ames assay, and water quality parameters. The study included information on treatment, mutagenicity data, and water quality data for source waters, finished waters, and distribution samples collected from five full-scale drinking water treatment plants, which used chlorine exclusively for disinfection. Four of the plants used surface water sources and the fifth plant used groundwater. Correlations between mutagenicity and water quality parameters are presented. The highest correlation was observed between mutagenicity and the total organic halide concentrations in the treated samples.

  19. Health Care Quality: Measuring Obesity in Performance Frameworks.

    PubMed

    Zvenyach, Tracy; Pickering, Matthew K

    2017-08-01

    Obesity affects over one-third of Americans and leads to several chronic and costly comorbid conditions. The national movement toward value-based care calls for a refocusing of efforts to address the US obesity epidemic. To help set the stage, the current landscape of obesity-specific quality measures was evaluated. Seven quality measure databases and nine professional societies were searched. Inclusion and exclusion criteria were applied. Measures were then classified by domain and by implementation in national public programs. Eleven obesity-specific quality measures in adults were identified (nine process and two outcome). Three measures received National Quality Forum (NQF) endorsement. Two measures were actively used within Centers for Medicare and Medicaid Services (CMS) programs. Only one measure was both NQF-endorsed and used by CMS. Limitations exist with respect to obesity-specific quality metrics. Such gaps provide opportunities for obesity care specialists to engage and offer valuable insights and pragmatic approaches toward quality measurement. © 2017 The Obesity Society.

  20. Deriving proper measurement uncertainty from Internal Quality Control data: An impossible mission?

    PubMed

    Ceriotti, Ferruccio

    2018-03-30

    Measurement uncertainty (MU) is a "non-negative parameter characterizing the dispersion of the quantity values being attributed to a measurand, based on the information used". In the clinical laboratory the most convenient way to calculate MU is the "top down" approach based on the use of Internal Quality Control data. As indicated in the definition, MU depends on the information used for its calculation and so different estimates of MU can be obtained. The most problematic aspect is how to deal with bias. In fact bias is difficult to detect and quantify and it should be corrected including only the uncertainty derived from this correction. Several approaches to calculate MU starting from Internal Quality Control data are presented. The minimum requirement is to use only the intermediate precision data, provided to include 6 months of results obtained with a commutable quality control material at a concentration close to the clinical decision limit. This approach is the minimal requirement and it is convenient for all those measurands that are especially used for monitoring or where a reference measurement system does not exist and so a reference for calculating the bias is lacking. Other formulas including the uncertainty of the value of the calibrator, including the bias from a commutable certified reference material or from a material specifically prepared for trueness verification, including the bias derived from External Quality Assessment schemes or from historical mean of the laboratory are presented and commented. MU is an important parameter, but a single, agreed upon way to calculate it in a clinical laboratory is not yet available. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  1. Parameter Search Algorithms for Microwave Radar-Based Breast Imaging: Focal Quality Metrics as Fitness Functions.

    PubMed

    O'Loughlin, Declan; Oliveira, Bárbara L; Elahi, Muhammad Adnan; Glavin, Martin; Jones, Edward; Popović, Milica; O'Halloran, Martin

    2017-12-06

    Inaccurate estimation of average dielectric properties can have a tangible impact on microwave radar-based breast images. Despite this, recent patient imaging studies have used a fixed estimate although this is known to vary from patient to patient. Parameter search algorithms are a promising technique for estimating the average dielectric properties from the reconstructed microwave images themselves without additional hardware. In this work, qualities of accurately reconstructed images are identified from point spread functions. As the qualities of accurately reconstructed microwave images are similar to the qualities of focused microscopic and photographic images, this work proposes the use of focal quality metrics for average dielectric property estimation. The robustness of the parameter search is evaluated using experimental dielectrically heterogeneous phantoms on the three-dimensional volumetric image. Based on a very broad initial estimate of the average dielectric properties, this paper shows how these metrics can be used as suitable fitness functions in parameter search algorithms to reconstruct clear and focused microwave radar images.

  2. History and background of quality measurement.

    PubMed

    Chun, Jonathan; Bafford, Andrea Chao

    2014-03-01

    Health care quality measurement has become increasingly emphasized, as providers and administrators respond to public and government demands for improved patient care. This article will review the evolution of surgical quality measurement and improvement from its infancy in the 1850s to the vast efforts being undertaken today.

  3. Quantitative analysis of aircraft multispectral-scanner data and mapping of water-quality parameters in the James River in Virginia

    NASA Technical Reports Server (NTRS)

    Johnson, R. W.; Bahn, G. S.

    1977-01-01

    Statistical analysis techniques were applied to develop quantitative relationships between in situ river measurements and the remotely sensed data that were obtained over the James River in Virginia on 28 May 1974. The remotely sensed data were collected with a multispectral scanner and with photographs taken from an aircraft platform. Concentration differences among water quality parameters such as suspended sediment, chlorophyll a, and nutrients indicated significant spectral variations. Calibrated equations from the multiple regression analysis were used to develop maps that indicated the quantitative distributions of water quality parameters and the dispersion characteristics of a pollutant plume entering the turbid river system. Results from further analyses that use only three preselected multispectral scanner bands of data indicated that regression coefficients and standard errors of estimate were not appreciably degraded compared with results from the 10-band analysis.

  4. More quality measures versus measuring what matters: a call for balance and parsimony

    PubMed Central

    Nelson, Eugene C; Pryor, David B; James, Brent; Swensen, Stephen J; Kaplan, Gary S; Weissberg, Jed I; Bisognano, Maureen; Yates, Gary R; Hunt, Gordon C

    2012-01-01

    External groups requiring measures now include public and private payers, regulators, accreditors and others that certify performance levels for consumers, patients and payers. Although benefits have accrued from the growth in quality measurement, the recent explosion in the number of measures threatens to shift resources from improving quality to cover a plethora of quality-performance metrics that may have a limited impact on the things that patients and payers want and need (ie, better outcomes, better care, and lower per capita costs). Here we propose a policy that quality measurement should be: balanced to meet the need of end users to judge quality and cost performance and the need of providers to continuously improve the quality, outcomes and costs of their services; and parsimonious to measure quality, outcomes and costs with appropriate metrics that are selected based on end-user needs. PMID:22893696

  5. More quality measures versus measuring what matters: a call for balance and parsimony.

    PubMed

    Meyer, Gregg S; Nelson, Eugene C; Pryor, David B; James, Brent; Swensen, Stephen J; Kaplan, Gary S; Weissberg, Jed I; Bisognano, Maureen; Yates, Gary R; Hunt, Gordon C

    2012-11-01

    External groups requiring measures now include public and private payers, regulators, accreditors and others that certify performance levels for consumers, patients and payers. Although benefits have accrued from the growth in quality measurement, the recent explosion in the number of measures threatens to shift resources from improving quality to cover a plethora of quality-performance metrics that may have a limited impact on the things that patients and payers want and need (ie, better outcomes, better care, and lower per capita costs). Here we propose a policy that quality measurement should be: balanced to meet the need of end users to judge quality and cost performance and the need of providers to continuously improve the quality, outcomes and costs of their services; and parsimonious to measure quality, outcomes and costs with appropriate metrics that are selected based on end-user needs.

  6. Determination of parameters of a nuclear reactor through noise measurements

    DOEpatents

    Cohn, C.E.

    1975-07-15

    A method of measuring parameters of a nuclear reactor by noise measurements is described. Noise signals are developed by the detectors placed in the reactor core. The polarity coincidence between the noise signals is used to develop quantities from which various parameters of the reactor can be calculated. (auth)

  7. The effects of differential and variable training on the quality parameters of a handball throw.

    PubMed

    Wagner, Herbert; Müller, Erich

    2008-01-01

    The aim of this study was to undertake a comprehensive temporal, effective, and practical training study (variable and differential learning) that would offer athletes the opportunity to increase their performance, and to analyse the effects by measuring kinematics and quality parameters. Two participants of differing standards--a player of the first Austrian League and an Olympic and World Champion--but of similar anthropometric characteristics were recruited. One of the participants (Austrian League) was tested on five different occasions (pre-test and four retests) to measure the effects of four different training phases using kinematic analysis. The results of the study indicate an increase in ball velocity within the differential training phases (first, second, and fourth phases), different proximal-to-distal sequences of the participants, and a change of movement pattern during training measured by the segment velocities and the angle-time courses.

  8. Measuring Up: Implementing a Dental Quality Measure in the Electronic Health Record Context

    PubMed Central

    Bhardwaj, Aarti; Ramoni, Rachel; Kalenderian, Elsbeth; Neumann, Ana; Hebballi, Nutan B; White, Joel M; McClellan, Lyle; Walji, Muhammad F

    2015-01-01

    Background Quality improvement requires quality measures that are validly implementable. In this work, we assessed the feasibility and performance of an automated electronic Meaningful Use dental clinical quality measure (percentage of children who received fluoride varnish). Methods We defined how to implement the automated measure queries in a dental electronic health record (EHR). Within records identified through automated query, we manually reviewed a subsample to assess the performance of the query. Results The automated query found 71.0% of patients to have had fluoride varnish compared to 77.6% found using the manual chart review. The automated quality measure performance was 90.5% sensitivity, 90.8% specificity, 96.9% positive predictive value, and 75.2% negative predictive value. Conclusions Our findings support the feasibility of automated dental quality measure queries in the context of sufficient structured data. Information noted only in the free text rather than in structured data would require natural language processing approaches to effectively query. Practical Implications To participate in self-directed quality improvement, dental clinicians must embrace the accountability era. Commitment to quality will require enhanced documentation in order to support near-term automated calculation of quality measures. PMID:26562736

  9. Line Narrowing Parameter Measurement by Modulation Spectroscopy

    NASA Technical Reports Server (NTRS)

    Dharamsi, Amin N.

    1998-01-01

    Accurate Characterization of Oxygen A-Band Line Parameters by Wavelength Modulation Spectroscopy with tunable diode lasers is an ongoing research at Old Dominion University, under sponsorship from NASA Langley research Center. The work proposed here will be undertaken under the guidance of Dr. William Chu and Dr. Lamont Poole of the Aerosol Research Branch at NASA Langley-Research Center in Hampton, Virginia. The research was started about two years ago and utilizes wavelength modulation absorption spectroscopy with higher harmonic detection, a technique that we developed at Old Dominion University, to obtain the absorption line characteristics of the Oxygen A-band rovibronic lines. Accurate characterization of this absorption band is needed for processing of data that will be obtained in experiments such as the NASA Stratospheric Aerosol and Gas Experiment III (SAGE III) as part of the US Mission to Planet Earth. The research work for Summer Fellowship undertook a measurement of the Dicke line-narrowing parameters of the Oxygen A-Band lines by using wavelength modulation spectroscopy. Our previous theoretical results had indicated that such a measurement could be done sensitively and in a convenient fashion by using this type of spectroscopy. In particular, theoretical results had indicated that the signal magnitude would depend on pressure in a manner that was very sensitive to the narrowing parameter. One of the major tasks undertaken during the summer of 1998 was to establish experimentally that these theoretical predictions were correct. This was done successfully and the results of the work are being prepared for publication. Experimental Results were obtained in which the magnitude of the signal was measured as a function of pressure, for various harmonic detection orders (N = 1, 2, 3, 4, 5). A comparison with theoretical results was made, and it was shown that the agreement between theory and experiment was very good. More importantly, however, it was shown

  10. Semen phthalate metabolites, semen quality parameters and serum reproductive hormones: A cross-sectional study in China.

    PubMed

    Wang, Yi-Xin; Zeng, Qiang; Sun, Yang; Yang, Pan; Wang, Peng; Li, Jin; Huang, Zhen; You, Ling; Huang, Yue-Hui; Wang, Cheng; Li, Yu-Feng; Lu, Wen-Qing

    2016-04-01

    Exposure to phthalates has been found to have adverse effects on male reproductive function in animals. However, the findings from human studies are inconsistent. Here we examined the associations of phthalate exposure with semen quality and reproductive hormones in a Chinese population using phthalate metabolite concentrations measured in semen as biomarkers. Semen (n = 687) and blood samples (n = 342) were collected from the male partners of sub-fertile couples who presented to the Reproductive Center of Tongji Hospital in Wuhan, China. Semen quality parameters and serum reproductive hormone levels were determined. Semen concentrations of 8 phthalate metabolites were assessed using high-performance liquid chromatography and tandem mass spectrometry. Associations of the semen phthalate metabolites with semen quality parameters and serum reproductive hormones were assessed using confounder-adjusted linear and logistic regression models. Semen phthalate metabolites were significantly associated with decreases in semen volume [mono-n-butyl phthalate (MBP), mono-(2-ethylhexyl) phthalate (MEHP), mono(2-ethyl-5-hydroxyhexyl) phthalate (MEHHP), mono(2-ethyl-5-oxohexyl) phthalate (MEOHP)], sperm curvilinear velocity [monobenzyl phthalate (MBzP), MEHP, the percentage of di-(2-ethylhexyl)-phthalate metabolites excreted as MEHP (%MEHP)], and straight-line velocity (MBzP, MEHP, %MEHP), and also associated with an increased percentage of abnormal heads and tails (MBzP) (all p for trend <0.05). These associations remained suggestive or significant after adjustment for multiple testing. There were no significant associations between semen phthalate metabolites and serum reproductive hormones. Our findings suggest that environmental exposure to phthalates may impair human semen quality. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Impacts of Different Types of Measurements on Estimating Unsaturatedflow Parameters

    NASA Astrophysics Data System (ADS)

    Shi, L.

    2015-12-01

    This study evaluates the value of different types of measurements for estimating soil hydraulic parameters. A numerical method based on ensemble Kalman filter (EnKF) is presented to solely or jointly assimilate point-scale soil water head data, point-scale soil water content data, surface soil water content data and groundwater level data. This study investigates the performance of EnKF under different types of data, the potential worth contained in these data, and the factors that may affect estimation accuracy. Results show that for all types of data, smaller measurements errors lead to faster convergence to the true values. Higher accuracy measurements are required to improve the parameter estimation if a large number of unknown parameters need to be identified simultaneously. The data worth implied by the surface soil water content data and groundwater level data is prone to corruption by a deviated initial guess. Surface soil moisture data are capable of identifying soil hydraulic parameters for the top layers, but exert less or no influence on deeper layers especially when estimating multiple parameters simultaneously. Groundwater level is one type of valuable information to infer the soil hydraulic parameters. However, based on the approach used in this study, the estimates from groundwater level data may suffer severe degradation if a large number of parameters must be identified. Combined use of two or more types of data is helpful to improve the parameter estimation.

  12. Estimation of Handling Qualities Parameters of the Tu-144 Supersonic Transport Aircraft from Flight Test Data

    NASA Technical Reports Server (NTRS)

    Curry, Timothy J.; Batterson, James G. (Technical Monitor)

    2000-01-01

    Low order equivalent system (LOES) models for the Tu-144 supersonic transport aircraft were identified from flight test data. The mathematical models were given in terms of transfer functions with a time delay by the military standard MIL-STD-1797A, "Flying Qualities of Piloted Aircraft," and the handling qualities were predicted from the estimated transfer function coefficients. The coefficients and the time delay in the transfer functions were estimated using a nonlinear equation error formulation in the frequency domain. Flight test data from pitch, roll, and yaw frequency sweeps at various flight conditions were used for parameter estimation. Flight test results are presented in terms of the estimated parameter values, their standard errors, and output fits in the time domain. Data from doublet maneuvers at the same flight conditions were used to assess the predictive capabilities of the identified models. The identified transfer function models fit the measured data well and demonstrated good prediction capabilities. The Tu-144 was predicted to be between level 2 and 3 for all longitudinal maneuvers and level I for all lateral maneuvers. High estimates of the equivalent time delay in the transfer function model caused the poor longitudinal rating.

  13. Validity and repeatability of inertial measurement units for measuring gait parameters.

    PubMed

    Washabaugh, Edward P; Kalyanaraman, Tarun; Adamczyk, Peter G; Claflin, Edward S; Krishnan, Chandramouli

    2017-06-01

    Inertial measurement units (IMUs) are small wearable sensors that have tremendous potential to be applied to clinical gait analysis. They allow objective evaluation of gait and movement disorders outside the clinic and research laboratory, and permit evaluation on large numbers of steps. However, repeatability and validity data of these systems are sparse for gait metrics. The purpose of this study was to determine the validity and between-day repeatability of spatiotemporal metrics (gait speed, stance percent, swing percent, gait cycle time, stride length, cadence, and step duration) as measured with the APDM Opal IMUs and Mobility Lab system. We collected data on 39 healthy subjects. Subjects were tested over two days while walking on a standard treadmill, split-belt treadmill, or overground, with IMUs placed in two locations: both feet and both ankles. The spatiotemporal measurements taken with the IMU system were validated against data from an instrumented treadmill, or using standard clinical procedures. Repeatability and minimally detectable change (MDC) of the system was calculated between days. IMUs displayed high to moderate validity when measuring most of the gait metrics tested. Additionally, these measurements appear to be repeatable when used on the treadmill and overground. The foot configuration of the IMUs appeared to better measure gait parameters; however, both the foot and ankle configurations demonstrated good repeatability. In conclusion, the IMU system in this study appears to be both accurate and repeatable for measuring spatiotemporal gait parameters in healthy young adults. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Impact of commercial housing systems and nutrient and energy intake on laying hen performance and egg quality parameters1

    PubMed Central

    Karcher, D. M.; Jones, D. R.; Abdo, Z.; Zhao, Y.; Shepherd, T. A.; Xin, H.

    2015-01-01

    The US egg industry is exploring alternative housing systems for laying hens. However, limited published research related to cage-free aviary systems and enriched colony cages exists related to production, egg quality, and hen nutrition. The laying hen's nutritional requirements and resulting productivity are well established with the conventional cage system, but diminutive research is available in regards to alternative housing systems. The restrictions exist with limited availability of alternative housing systems in research settings and the considerable expense for increased bird numbers in a replicate due to alternative housing system design. Therefore, the objective of the current study was to evaluate the impact of nutrient and energy intake on production and egg quality parameters from laying hens housed at a commercial facility. Lohmann LSL laying hens were housed in three systems: enriched colony cage, cage-free aviary, and conventional cage at a single commercial facility. Daily production records were collected along with dietary changes during 15 production periods (28-d each). Eggs were analyzed for shell strength, shell thickness, Haugh unit, vitelline membrane properties, and egg solids each period. An analysis of covariance (ANCOVA) coupled with a principal components analysis (PCA) approach was utilized to assess the impact of nutritional changes on production parameters and monitored egg quality factors. The traits of hen-day production and mortality had a response only in the PCA 2 direction. This finds that as house temperature and Met intake increases, there is an inflection point at which hen-day egg production is negatively effected. Dietary changes more directly influenced shell parameters, vitelline membrane parameters, and egg total solids as opposed to laying hen housing system. Therefore, further research needs to be conducted in controlled research settings on laying hen nutrient and energy intake in the alternative housing systems

  15. High resolution light microscopic evaluation of boar semen quality sperm cytoplasmic droplet retention in relationship with boar fertility parameters.

    PubMed

    Lovercamp, K W; Safranski, T J; Fischer, K A; Manandhar, G; Sutovsky, M; Herring, W; Sutovsky, P

    2007-01-01

    The purpose of this study was to investigate the relationship between fertility and quantitative measures of boar semen quality, including various patterns of sperm cytoplasmic droplet (CD) retention, as determined by high power differential interference contrast (DIC) microscopy. A total of 116 ejaculates were collected from a nucleus herd of 18 Large White boars over an eight month period. Semen quality parameters were analyzed for each ejaculate by calculating the percentage of normal spermatozoa, spermatozoa possessing a CD in the proximal, distal, or distal midpiece reflex position, total spermatozoa with an attached cytoplasmic droplet, spermatozoa with non-CD related aberrations and total spermatozoa with abnormalities. Of the 116 ejaculates received, 71 ejaculates from 13 boars had corresponding fertility data from single-sire inseminations of multiparous sows. The fertility data included farrowing rate (FR) and total number born (TNB). The monthly FR encompassed one month before and one month after the date of semen collection. Detection of differences for fertility and semen quality parameters was performed by separating the boars into either an above-average or below-average group based on the mean FR (74.01 +/- 1.43%) or TNB (12.34 +/- 0.17) for the study. For FR, the boars in the below-average group had a significantly lower percentage of normal spermatozoa and significantly higher percentage of spermatozoa possessing distal CDs, total attached CDs and total abnormalities compared to the boars in the above-average group. Conversely, for TNB there were no significant differences between the above- and below-average groups for the semen quality parameters. These data suggest that the attached CD may negatively affect FR, but not TNB. The detection of relationships between the boar fertility parameters and the retention of the sperm CD after ejaculation, document the advantage of high power DIC microscopy in conventional semen evaluation.

  16. The association between clinical parameters and glaucoma-specific quality of life in Chinese primary open-angle glaucoma patients.

    PubMed

    Lee, Jacky W Y; Chan, Catherine W S; Chan, Jonathan C H; Li, Q; Lai, Jimmy S M

    2014-08-01

    OBJECTIVE. To investigate the association between clinical measurements and glaucoma-specific quality of life in Chinese glaucoma patients. DESIGN. Cross-sectional study. SETTING. An academic hospital in Hong Kong. PATIENTS. A Chinese translation of the Glaucoma Quality of Life-15 questionnaire was completed by 51 consecutive patients with bilateral primary open-angle glaucoma. The binocular means of several clinical measurements were correlated with Glaucoma Quality of Life-15 findings using Pearson's correlation coefficient and linear regression. The measurements were the visual field index and pattern standard deviation from the Humphrey Field Analyzer, Snellen best-corrected visual acuity, presenting intra-ocular pressure, current intra-ocular pressure, average retinal nerve fibre layer thickness via optical coherence tomography, and the number of topical anti-glaucoma medications being used. RESULTS. In these patients, there was a significant correlation and linear relationship between a poorer Glaucoma Quality of Life-15 score and a lower visual field index (r=0.3, r(2)=0.1, P=0.01) and visual acuity (r=0.3, r(2)=0.1, P=0.03). A thinner retinal nerve fibre layer also correlated with a poorer Glaucoma Quality of Life-15 score, but did not attain statistical significance (r=0.3, P=0.07). There were no statistically significant correlations for the other clinical parameters with the Glaucoma Quality of Life-15 scores (all P values being >0.7). The three most problematic activities affecting quality of life were "adjusting to bright lights", "going from a light to a dark room or vice versa", and "seeing at night". CONCLUSION. For Chinese primary open-angle glaucoma patients, binocular visual field index and visual acuity correlated linearly with glaucoma-specific quality of life, and activities involving dark adaptation were the most problematic.

  17. On-Line Water Quality Parameters as Indicators of Distribution System Contamination

    EPA Science Inventory

    At a time when the safety and security of services we have typically taken for granted are under question, a real-time or near real-time method of monitoring changes in water quality parameters could provide a critical line of defense in protecting public health. This study was u...

  18. Influence of extrusion-cooking parameters on some quality aspects of precooked pasta-like products.

    PubMed

    Wójtowicz, A; Mościcki, L

    2009-06-01

    The present article aims to evaluate some quality parameters and texture characteristics of precooked wheat pasta-like products. Using the methods for pasta and instant noodles the tested parameters were water absorption, starch gelatinization degree, cooking losses, and hardness. The texture profile was characterized using Zwick apparatus by cutting test with the head speed of 10 mm/min and expressed as hardness and firmness of hydrated products. SEM pictures were used to illustrate the internal structure of dry and cooked pasta-like products. Dough moisture content and process conditions influenced all tested quality parameters of the pasta-like products processed on a modified single screw extrusion-cooker TS-45 with L: D = 16: 1. Good organoleptical quality (notes higher than 4 in a 5-point scale) and firm texture were observed for common wheat flour pasta processed at 30% m.c. Hardness and firmness of hydrated products lowered with a longer hydration time in hot water. The firmest texture and low stickiness was observed for products with a highest starch gelatinization degree.

  19. Assessing biodiesel quality parameters for wastewater grown Chlorella sp.

    PubMed

    Bagul, Samadhan Yuvraj; K Bharti, Randhir; Dhar, Dolly Wattal

    2017-07-01

    Microalgae are reported as the efficient source of renewable biodiesel which should be able to meet the global demand of transport fuels. Present study is focused on assessment of wastewater grown indigenous microalga Chlorella sp. for fuel quality parameters. This was successfully grown in secondary treated waste water diluted with tap water (25% dilution) in glass house. The microalga showed a dry weight of 0.849 g L -1 with lipid content of 27.1% on dry weight basis on 21st day of incubation. After transesterification, the yield of fatty acid methyl ester was 80.64% with major fatty acids as palmitic, linoleic, oleic and linolenic. The physical parameters predicted from empirical equations in the biodiesel showed cetane number as 56.5, iodine value of 75.5 g I 2 100 g -1 , high heating value 40.1 MJ kg -1 , flash point 135 °C, kinematic viscosity 4.05 mm 2 s -1 with density of 0.86 g cm 3 and cold filter plugging point as 0.7 °C. Fourier transform infra-red (FTIR), 1 H, 13 C NMR spectrum confirmed the chemical nature of biodiesel. The results indicated that the quality of biodiesel was almost as per the criterion of ASTM standards; hence, wastewater grown Chlorella sp. can be used as a promising strain for biodiesel production.

  20. UCMS - A new signal parameter measurement system using digital signal processing techniques. [User Constraint Measurement System

    NASA Technical Reports Server (NTRS)

    Choi, H. J.; Su, Y. T.

    1986-01-01

    The User Constraint Measurement System (UCMS) is a hardware/software package developed by NASA Goddard to measure the signal parameter constraints of the user transponder in the TDRSS environment by means of an all-digital signal sampling technique. An account is presently given of the features of UCMS design and of its performance capabilities and applications; attention is given to such important aspects of the system as RF interface parameter definitions, hardware minimization, the emphasis on offline software signal processing, and end-to-end link performance. Applications to the measurement of other signal parameters are also discussed.

  1. Experimental equipment for measuring of rotary air motors parameters

    NASA Astrophysics Data System (ADS)

    Dvořák, Lukáš; Fojtášek, Kamil; Řeháček, Vojtěch

    In the article the construction of an experimental device for measuring the parameters of small rotary air motors is described. Further a measurement methodology and measured data processing are described. At the end of the article characteristics of the chosen air motor are presented.

  2. Measuring Parameters of Massive Black Hole Binaries with Partially Aligned Spins

    NASA Technical Reports Server (NTRS)

    Lang, Ryan N.; Hughes, Scott A.; Cornish, Neil J.

    2011-01-01

    The future space-based gravitational wave detector LISA will be able to measure parameters of coalescing massive black hole binaries, often to extremely high accuracy. Previous work has demonstrated that the black hole spins can have a strong impact on the accuracy of parameter measurement. Relativistic spin-induced precession modulates the waveform in a manner which can break degeneracies between parameters, in principle significantly improving how well they are measured. Recent studies have indicated, however, that spin precession may be weak for an important subset of astrophysical binary black holes: those in which the spins are aligned due to interactions with gas. In this paper, we examine how well a binary's parameters can be measured when its spins are partially aligned and compare results using waveforms that include higher post-Newtonian harmonics to those that are truncated at leading quadrupole order. We find that the weakened precession can substantially degrade parameter estimation, particularly for the "extrinsic" parameters sky position and distance. Absent higher harmonics, LISA typically localizes the sky position of a nearly aligned binary about an order of magnitude less accurately than one for which the spin orientations are random. Our knowledge of a source's sky position will thus be worst for the gas-rich systems which are most likely to produce electromagnetic counterparts. Fortunately, higher harmonics of the waveform can make up for this degradation. By including harmonics beyond the quadrupole in our waveform model, we find that the accuracy with which most of the binary's parameters are measured can be substantially improved. In some cases, the improvement is such that they are measured almost as well as when the binary spins are randomly aligned.

  3. DATA QUALITY OBJECTIVES AND MEASUREMENT QUALITY OBJECTIVES FOR RESEARCH PROJECTS

    EPA Science Inventory

    The paper provides assistance with systematic planning using measurement quality objectives to those working on research projects. These performance criteria are more familiar to researchers than data quality objectives because they are more closely associated with the measuremen...

  4. Characterization of Thermal Parameters for Improving Pyranometer and Pyrgeometer Measurements

    NASA Technical Reports Server (NTRS)

    Tsay, Si-Chee; Jhabvala, Murzy D.; Ji, Qiang; Rapshun, David; Shu, Peter K.

    2000-01-01

    Since the introduction of thermopile, pyranometers (solar, e.g., 0.3-3.0 micrometers) and pyrgeometers (terrestrial, e.g., 4-50 micrometers) have become instruments commonly used for measuring the broadband hemispherical irradiances at the surface in a long-term, monitoring mode for decades. These commercially available radiometers have been manufactured in several countries such as from the United States, Asia, and Europe, and are generally reliable and economical. These worldwide distributions of surface measurements become even more important in the era of Earth remote sensing in studying climate change. However, recent studies from field campaigns have pointed out that erroneous factors (e.g., temperature gradients between the filter dome and detector, emissivity of the thermopile) are responsible for the unacceptable level of uncertainty (e.g., 20 W m(exp -2)). Using a newly developed instrument of Quantum Well Infrared Photodetector (QWTP), we have characterized the brightness temperature fields of pyranometers and pyrgeometers under various sky conditions. The QWIP is based on the superlattice (GaAs/AlGaAs) technology and has a noise equivalent temperature (NEAT) less than 0.1 K. The quality of pyranometer and pyrgeometer measure- ments can be improved largely by applying proper knowledge of the thermal parameters affecting the operation of the thermopile systems. Data correction procedure and algorithm will be presented and discussed.

  5. Multivariate analysis of drinking water quality parameters in Bhopal, India.

    PubMed

    Parashar, Charu; Verma, Neelam; Dixit, Savita; Shrivastava, Rajneesh

    2008-05-01

    Pollution of water bodies is one of the areas of major concern to environmentalists. Water quality is an index of health and well being of a society. Industrialization, urbanization and modern agriculture practices have direct impact on the water resources. These factors influence the water resources quantitatively and qualitatively. The study area selected were the Upper lake and Kolar reservoir of Bhopal, the state capital of Madhya Pradesh, India. The Upper lake and Kolar reservoir both are the important sources of potable water supply for the Bhopal city. The physico-chemical parameters like temperature, pH, turbidity, total hardness, alkalinity, BOD, COD, Chloride, nitrate and phosphate were studied to ascertain the drinking water quality.

  6. Measuring patient-perceived hospital service quality: a conceptual framework.

    PubMed

    Pai, Yogesh P; Chary, Satyanarayana T

    2016-04-18

    Purpose - Although measuring healthcare service quality is not a new phenomenon, the instruments used to measure are timeworn. With the shift in focus to patient centric processes in hospitals and recognizing healthcare to be different compared to other services, service quality measurement needs to be tuned specifically to healthcare. The purpose of this paper is to design a conceptual framework for measuring patient perceived hospital service quality (HSQ), based on existing service quality literature. Design/methodology/approach - Using HSQ theories, expanding existing healthcare service models and literature, a conceptual framework is proposed to measure HSQ. The paper outlines patient perceived service quality dimensions. Findings - An instrument for measuring HSQ dimensions is developed and compared with other service quality measuring instruments. The latest dimensions are in line with previous studies, but a relationship dimension is added. Practical implications - The framework empowers managers to assess healthcare quality in corporate, public and teaching hospitals. Originality/value - The paper helps academics and practitioners to assess HSQ from a patient perspective.

  7. Quality Measures for the Care of Patients with Insomnia

    PubMed Central

    Edinger, Jack D.; Buysse, Daniel J.; Deriy, Ludmila; Germain, Anne; Lewin, Daniel S.; Ong, Jason C.; Morgenthaler, Timothy I.

    2015-01-01

    The American Academy of Sleep Medicine (AASM) commissioned five Workgroups to develop quality measures to optimize management and care for patients with common sleep disorders including insomnia. Following the AASM process for quality measure development, this document describes measurement methods for two desirable outcomes of therapy, improving sleep quality or satisfaction, and improving daytime function, and for four processes important to achieving these goals. To achieve the outcome of improving sleep quality or satisfaction, pre- and post-treatment assessment of sleep quality or satisfaction and providing an evidence-based treatment are recommended. To realize the outcome of improving daytime functioning, pre- and post-treatment assessment of daytime functioning, provision of an evidence-based treatment, and assessment of treatment-related side effects are recommended. All insomnia measures described in this report were developed by the Insomnia Quality Measures Workgroup and approved by the AASM Quality Measures Task Force and the AASM Board of Directors. The AASM recommends the use of these measures as part of quality improvement programs that will enhance the ability to improve care for patients with insomnia. Citation: Edinger JD, Buysse DJ, Deriy L, Germain A, Lewin DS, Ong JC, Morgenthaler TI. Quality measures for the care of patients with insomnia. J Clin Sleep Med 2015;11(3):311–334. PMID:25700881

  8. [Quant efficiency of the detection as a quality parameter of the visualization equipment].

    PubMed

    Morgun, O N; Nemchenko, K E; Rogov, Iu V

    2003-01-01

    The critical parameter of notion "quant efficiency of detection" is defined in the paper. Different methods of specifying the detection quant efficiency (DQE) are under discussion. Thus, techniques of DQE determination for a whole unit and means of DQE finding at terminal space frequency are addressed. The notion of DQE at zero frequency is in the focus of attention. Finally, difficulties occurring in determining the above parameter as well as its disadvantages (as a parameter characterizing the quality of X-ray irradiation visualizing systems) are also discussed.

  9. Innovative United Kingdom Approaches To Measuring Service Quality.

    ERIC Educational Resources Information Center

    Winkworth, Ian

    2001-01-01

    Reports on approaches to measuring the service quality of academic libraries in the United Kingdom. Discusses the role of government and the national background of quality measurement; measurement frameworks; better use of statistics; benchmarking; measuring user satisfaction; and possible future development. (Author/LRW)

  10. Using Clinical Data Standards to Measure Quality: A New Approach.

    PubMed

    D'Amore, John D; Li, Chun; McCrary, Laura; Niloff, Jonathan M; Sittig, Dean F; McCoy, Allison B; Wright, Adam

    2018-04-01

     Value-based payment for care requires the consistent, objective calculation of care quality. Previous initiatives to calculate ambulatory quality measures have relied on billing data or individual electronic health records (EHRs) to calculate and report performance. New methods for quality measure calculation promoted by federal regulations allow qualified clinical data registries to report quality outcomes based on data aggregated across facilities and EHRs using interoperability standards.  This research evaluates the use of clinical document interchange standards as the basis for quality measurement.  Using data on 1,100 patients from 11 ambulatory care facilities and 5 different EHRs, challenges to quality measurement are identified and addressed for 17 certified quality measures.  Iterative solutions were identified for 14 measures that improved patient inclusion and measure calculation accuracy. Findings validate this approach to improving measure accuracy while maintaining measure certification.  Organizations that report care quality should be aware of how identified issues affect quality measure selection and calculation. Quality measure authors should consider increasing real-world validation and the consistency of measure logic in respect to issues identified in this research. Schattauer GmbH Stuttgart.

  11. An approach to measure parameter sensitivity in watershed ...

    EPA Pesticide Factsheets

    Hydrologic responses vary spatially and temporally according to watershed characteristics. In this study, the hydrologic models that we developed earlier for the Little Miami River (LMR) and Las Vegas Wash (LVW) watersheds were used for detail sensitivity analyses. To compare the relative sensitivities of the hydrologic parameters of these two models, we used Normalized Root Mean Square Error (NRMSE). By combining the NRMSE index with the flow duration curve analysis, we derived an approach to measure parameter sensitivities under different flow regimes. Results show that the parameters related to groundwater are highly sensitive in the LMR watershed, whereas the LVW watershed is primarily sensitive to near surface and impervious parameters. The high and medium flows are more impacted by most of the parameters. Low flow regime was highly sensitive to groundwater related parameters. Moreover, our approach is found to be useful in facilitating model development and calibration. This journal article describes hydrological modeling of climate change and land use changes on stream hydrology, and elucidates the importance of hydrological model construction in generating valid modeling results.

  12. Quantitative comparison of measurements of urgent care service quality.

    PubMed

    Qin, Hong; Prybutok, Victor; Prybutok, Gayle

    2016-01-01

    Service quality and patient satisfaction are essential to health care organization success. Parasuraman, Zeithaml, and Berry introduced SERVQUAL, a prominent service quality measure not yet applied to urgent care. We develop an instrument to measure perceived service quality and identify the determinants of patient satisfaction/ behavioral intentions. We examine the relationships among perceived service quality, patient satisfaction and behavioral intentions, and demonstrate that urgent care service quality is not equivalent using measures of perceptions only, differences of expectations minus perceptions, ratio of perceptions to expectations, and the log of the ratio. Perceptions provide the best measure of urgent care service quality.

  13. Quality Measures for the Care of Patients with Narcolepsy

    PubMed Central

    Krahn, Lois E.; Hershner, Shelley; Loeding, Lauren D.; Maski, Kiran P.; Rifkin, Daniel I.; Selim, Bernardo; Watson, Nathaniel F.

    2015-01-01

    The American Academy of Sleep Medicine (AASM) commissioned a Workgroup to develop quality measures for the care of patients with narcolepsy. Following a comprehensive literature search, 306 publications were found addressing quality care or measures. Strength of association was graded between proposed process measures and desired outcomes. Following the AASM process for quality measure development, we identified three outcomes (including one outcome measure) and seven process measures. The first desired outcome was to reduce excessive daytime sleepiness by employing two process measures: quantifying sleepiness and initiating treatment. The second outcome was to improve the accuracy of diagnosis by employing the two process measures: completing both a comprehensive sleep history and an objective sleep assessment. The third outcome was to reduce adverse events through three steps: ensuring treatment follow-up, documenting medical comorbidities, and documenting safety measures counseling. All narcolepsy measures described in this report were developed by the Narcolepsy Quality Measures Work-group and approved by the AASM Quality Measures Task Force and the AASM Board of Directors. The AASM recommends the use of these measures as part of quality improvement programs that will enhance the ability to improve care for patients with narcolepsy. Citation: Krahn LE, Hershner S, Loeding LD, Maski KP, Rifkin DI, Selim B, Watson NF. Quality measures for the care of patients with narcolepsy. J Clin Sleep Med 2015;11(3):335–355. PMID:25700880

  14. Adaptive quantization-parameter clip scheme for smooth quality in H.264/AVC.

    PubMed

    Hu, Sudeng; Wang, Hanli; Kwong, Sam

    2012-04-01

    In this paper, we investigate the issues over the smooth quality and the smooth bit rate during rate control (RC) in H.264/AVC. An adaptive quantization-parameter (Q(p)) clip scheme is proposed to optimize the quality smoothness while keeping the bit-rate fluctuation at an acceptable level. First, the frame complexity variation is studied by defining a complexity ratio between two nearby frames. Second, the range of the generated bits is analyzed to prevent the encoder buffer from overflow and underflow. Third, based on the safe range of the generated bits, an optimal Q(p) clip range is developed to reduce the quality fluctuation. Experimental results demonstrate that the proposed Q(p) clip scheme can achieve excellent performance in quality smoothness and buffer regulation.

  15. International Airline Quality Measurement

    DOT National Transportation Integrated Search

    1998-01-01

    Historically, airline quality has been measured through the use of surveys that ask the consumers to make a comparison between expectations and outcomes. This method was informative but very cumbersome in a rapidly changing environment. This paper ou...

  16. Adopting software quality measures for healthcare processes.

    PubMed

    Yildiz, Ozkan; Demirörs, Onur

    2009-01-01

    In this study, we investigated the adoptability of software quality measures for healthcare process measurement. Quality measures of ISO/IEC 9126 are redefined from a process perspective to build a generic healthcare process quality measurement model. Case study research method is used, and the model is applied to a public hospital's Entry to Care process. After the application, weak and strong aspects of the process can be easily observed. Access audibility, fault removal, completeness of documentation, and machine utilization are weak aspects and these aspects are the candidates for process improvement. On the other hand, functional completeness, fault ratio, input validity checking, response time, and throughput time are the strong aspects of the process.

  17. Impact of commercial housing systems and nutrient and energy intake on laying hen performance and egg quality parameters.

    PubMed

    Karcher, D M; Jones, D R; Abdo, Z; Zhao, Y; Shepherd, T A; Xin, H

    2015-03-01

    The US egg industry is exploring alternative housing systems for laying hens. However, limited published research related to cage-free aviary systems and enriched colony cages exists related to production, egg quality, and hen nutrition. The laying hen's nutritional requirements and resulting productivity are well established with the conventional cage system, but diminutive research is available in regards to alternative housing systems. The restrictions exist with limited availability of alternative housing systems in research settings and the considerable expense for increased bird numbers in a replicate due to alternative housing system design. Therefore, the objective of the current study was to evaluate the impact of nutrient and energy intake on production and egg quality parameters from laying hens housed at a commercial facility. Lohmann LSL laying hens were housed in three systems: enriched colony cage, cage-free aviary, and conventional cage at a single commercial facility. Daily production records were collected along with dietary changes during 15 production periods (28-d each). Eggs were analyzed for shell strength, shell thickness, Haugh unit, vitelline membrane properties, and egg solids each period. An analysis of covariance (ANCOVA) coupled with a principal components analysis (PCA) approach was utilized to assess the impact of nutritional changes on production parameters and monitored egg quality factors. The traits of hen-day production and mortality had a response only in the PCA 2 direction. This finds that as house temperature and Met intake increases, there is an inflection point at which hen-day egg production is negatively effected. Dietary changes more directly influenced shell parameters, vitelline membrane parameters, and egg total solids as opposed to laying hen housing system. Therefore, further research needs to be conducted in controlled research settings on laying hen nutrient and energy intake in the alternative housing systems

  18. Chief Complaint-Based Performance Measures: A New Focus For Acute Care Quality Measurement

    PubMed Central

    Griffey, Richard T; Pines, Jesse M.; Farley, Heather L.; Phelan, Michael P; Beach, Christopher; Schuur, Jeremiah D; Venkatesh, Arjun K.

    2014-01-01

    Performance measures are increasingly important to guide meaningful quality improvement efforts and value-based reimbursement. Populations included in most current hospital performance measures are defined by recorded diagnoses using International Disease Classification (ICD)-9 codes in administrative claims data. While the diagnosis-centric approach allows the assessment of disease-specific quality, it fails to measure one of the primary functions of emergency department (ED) care which involves diagnosing, risk-stratifying, and treating patients’ potentially life-threatening conditions based on symptoms (i.e. chief complaints). In this paper we propose chief complaint-based quality measures as a means to enhance the evaluation of quality and value in emergency care. We discuss the potential benefits of chief-complaint based measures, describe opportunities to mitigate challenges, propose an example measure set, and present several recommendations to advance this paradigm in ED-based performance measurement. PMID:25443989

  19. Effects of Various Architectural Parameters on Six Room Acoustical Measures in Auditoria.

    NASA Astrophysics Data System (ADS)

    Chiang, Wei-Hwa

    The effects of architectural parameters on six room acoustical measures were investigated by means of correlation analyses, factor analyses and multiple regression analyses based on data taken in twenty halls. Architectural parameters were used to estimate acoustical measures taken at individual locations within each room as well as the averages and standard deviations of all measured values in the rooms. The six acoustical measures were Early Decay Time (EDT10), Clarity Index (C80), Overall Level (G), Bass Ratio based on Early Decay Time (BR(EDT)), Treble Ratio based on Early Decay Time (TR(EDT)), and Early Inter-aural Cross Correlation (IACC80). A comprehensive method of quantifying various architectural characteristics of rooms was developed to define a large number of architectural parameters that were hypothesized to effect the acoustical measurements made in the rooms. This study quantitatively confirmed many of the principles used in the design of concert halls and auditoria. Three groups of room architectural parameters such as the parameters associated with the depth of diffusing surfaces were significantly correlated with the hall standard deviations of most of the acoustical measures. Significant differences of statistical relations among architectural parameters and receiver specific acoustical measures were found between a group of music halls and a group of lecture halls. For example, architectural parameters such as the relative distance from the receiver to the overhead ceiling increased the percentage of the variance of acoustical measures that was explained by Barron's revised theory from approximately 70% to 80% only when data were taken in the group of music halls. This study revealed the major architectural parameters which have strong relations with individual acoustical measures forming the basis for a more quantitative method for advancing the theoretical design of concert halls and other auditoria. The results of this study provide

  20. Measurement of carrier transport and recombination parameter in heavily doped silicon

    NASA Technical Reports Server (NTRS)

    Swanson, Richard M.

    1986-01-01

    The minority carrier transport and recombination parameters in heavily doped bulk silicon were measured. Both Si:P and Si:B with bulk dopings from 10 to the 17th and 10 to the 20th power/cu cm were studied. It is shown that three parameters characterize transport in bulk heavily doped Si: the minority carrier lifetime tau, the minority carrier mobility mu, and the equilibrium minority carrier density of n sub 0 and p sub 0 (in p-type and n-type Si respectively.) However, dc current-voltage measurements can never measure all three of these parameters, and some ac or time-transient experiment is required to obtain the values of these parameters as a function of dopant density. Using both dc electrical measurements on bipolar transitors with heavily doped base regions and transients optical measurements on heavily doped bulk and epitaxially grown samples, lifetime, mobility, and bandgap narrowing were measured as a function of both p and n type dopant densities. Best fits of minority carrier mobility, bandgap narrowing and lifetime as a function of doping density (in the heavily doped range) were constructed to allow accurate modeling of minority carrier transport in heavily doped Si.

  1. Nurse Reported Quality of Care: A Measure of Hospital Quality

    PubMed Central

    McHugh, Matthew D.; Stimpfel, Amy Witkoski

    2013-01-01

    As the primary providers of round-the-clock bedside care, nurses are well positioned to report on hospital quality of care. Researchers have not examined how nurses’ reports of quality correspond with standard process or outcomes measures of quality. We assess the validity of evaluating hospital quality by aggregating hospital nurses’ responses to a single item that asks them to report on quality of care. We found that a 10% increment in the proportion of nurses reporting excellent quality of care was associated with lower odds of mortality and failure to rescue; greater patient satisfaction; and higher composite process of care scores for acute myocardial infarction, pneumonia, and surgical patients. Nurse reported quality of care is a useful indicator of hospital performance. PMID:22911102

  2. Water and sediment quality parameters in the Chalan Beel, the largest wetland of Bangladesh

    NASA Astrophysics Data System (ADS)

    Sayeed, Md. Abu; Hossain, Mostafa Ali Reza; Wahab, Md. Abdul; Hasan, Md. Tawheed; Simon, Kumar Das; Mazumder, Sabuj Kanti

    2015-07-01

    A study was conducted to investigate the status of the water and sediment quality in the Chalan Beel-a major fresh water fish reservoir of the country for a period of one year from July 2007 to June 2008. The mean values of water quality parameters (depth: 214.73±152.22 cm, temperature 27.68±4.26°C, transparency 123±82 cm, pH 9.7±0.47, total alkalinity 137±42 mg/L, conductivity 307±147 μs/cm, total dissolved solids 183±89 mg/L, ammonia-N 0.27±0.39 mg/L, nitrate-N 0.09±0.07 mg/L, phosphate-P 2.01±2.53 mg/L) and sediment quality parameters (pH 7.21±0.35, organic matter 2.59±0.52%, total nitrogen 0.09±0.04%, available phosphorus 5.4±3.6 Meq./100 g and exchangeable potassium 0.43±0.14 Meq./100 g) were within the range recommended for most of the inland fishes of Bangladesh. Although the water and sediment quality parameters except ammonia and phosphate are in the suitable range, the overall results suggest that better management techniques should be practiced in order to overcome the declining trend of associated aquatic life (fauna and flora) of this important fresh water body of Bangladesh.

  3. Quality Measures in Stroke

    PubMed Central

    Poisson, Sharon N.; Josephson, S. Andrew

    2011-01-01

    Stroke is a major public health burden, and accounts for many hospitalizations each year. Due to gaps in practice and recommended guidelines, there has been a recent push toward implementing quality measures to be used for improving patient care, comparing institutions, as well as for rewarding or penalizing physicians through pay-for-performance. This article reviews the major organizations involved in implementing quality metrics for stroke, and the 10 major metrics currently being tracked. We also discuss possible future metrics and the implications of public reporting and using metrics for pay-for-performance. PMID:23983840

  4. Relationship between changes in vasomotor symptoms and changes in menopause-specific quality of life and sleep parameters.

    PubMed

    Pinkerton, JoAnn V; Abraham, Lucy; Bushmakin, Andrew G; Cappelleri, Joseph C; Komm, Barry S

    2016-10-01

    This study characterizes and quantifies the relationship of vasomotor symptoms (VMS) of menopause with menopause-specific quality of life (MSQOL) and sleep parameters to help predict treatment outcomes and inform treatment decision-making. Data were derived from a 12-week randomized, double-blind, placebo-controlled phase 3 trial that evaluated effects of two doses of conjugated estrogens/bazedoxifene on VMS in nonhysterectomized postmenopausal women (N = 318, mean age = 53.39) experiencing at least seven moderate to severe hot flushes (HFs) per day or at least 50 per week. Repeated measures models were used to determine relationships between HF frequency and severity and outcomes on the Menopause-Specific Quality of Life questionnaire and the Medical Outcomes Study sleep scale. Sensitivity analyses were performed to check assumptions of linearity between VMS and outcomes. Frequency and severity of HFs showed approximately linear relationships with MSQOL and sleep parameters. Sensitivity analyses supported assumptions of linearity. The largest changes associated with a reduction of five HFs and a 0.5-point decrease in severity occurred in the Menopause-Specific Quality of Life vasomotor functioning domain (0.78 for number of HFs and 0.98 for severity) and the Medical Outcomes Study sleep disturbance (7.38 and 4.86) and sleep adequacy (-5.60 and -4.66) domains and the two overall sleep problems indices (SPI: 5.17 and 3.63; SPII: 5.82 and 3.83). Frequency and severity of HFs have an approximately linear relationship with MSQOL and sleep parameters-that is, improvements in HFs are associated with improvements in MSQOL and sleep. Such relationships may enable clinicians to predict changes in sleep and MSQOL expected from various VMS treatments.

  5. Measuring up: Implementing a dental quality measure in the electronic health record context.

    PubMed

    Bhardwaj, Aarti; Ramoni, Rachel; Kalenderian, Elsbeth; Neumann, Ana; Hebballi, Nutan B; White, Joel M; McClellan, Lyle; Walji, Muhammad F

    2016-01-01

    Quality improvement requires using quality measures that can be implemented in a valid manner. Using guidelines set forth by the Meaningful Use portion of the Health Information Technology for Economic and Clinical Health Act, the authors assessed the feasibility and performance of an automated electronic Meaningful Use dental clinical quality measure to determine the percentage of children who received fluoride varnish. The authors defined how to implement the automated measure queries in a dental electronic health record. Within records identified through automated query, the authors manually reviewed a subsample to assess the performance of the query. The automated query results revealed that 71.0% of patients had fluoride varnish compared with the manual chart review results that indicated 77.6% of patients had fluoride varnish. The automated quality measure performance results indicated 90.5% sensitivity, 90.8% specificity, 96.9% positive predictive value, and 75.2% negative predictive value. The authors' findings support the feasibility of using automated dental quality measure queries in the context of sufficient structured data. Information noted only in free text rather than in structured data would require using natural language processing approaches to effectively query electronic health records. To participate in self-directed quality improvement, dental clinicians must embrace the accountability era. Commitment to quality will require enhanced documentation to support near-term automated calculation of quality measures. Copyright © 2016 American Dental Association. Published by Elsevier Inc. All rights reserved.

  6. Parameter Estimation for Geoscience Applications Using a Measure-Theoretic Approach

    NASA Astrophysics Data System (ADS)

    Dawson, C.; Butler, T.; Mattis, S. A.; Graham, L.; Westerink, J. J.; Vesselinov, V. V.; Estep, D.

    2016-12-01

    Effective modeling of complex physical systems arising in the geosciences is dependent on knowing parameters which are often difficult or impossible to measure in situ. In this talk we focus on two such problems, estimating parameters for groundwater flow and contaminant transport, and estimating parameters within a coastal ocean model. The approach we will describe, proposed by collaborators D. Estep, T. Butler and others, is based on a novel stochastic inversion technique based on measure theory. In this approach, given a probability space on certain observable quantities of interest, one searches for the sets of highest probability in parameter space which give rise to these observables. When viewed as mappings between sets, the stochastic inversion problem is well-posed in certain settings, but there are computational challenges related to the set construction. We will focus the talk on estimating scalar parameters and fields in a contaminant transport setting, and in estimating bottom friction in a complicated near-shore coastal application.

  7. Finding an optimal strategy for measuring the quality of groundwater as a source for drinking water

    NASA Astrophysics Data System (ADS)

    van Driezum, Inge; Saracevic, Ernis; Scheibz, Jürgen; Zessner, Matthias; Kirschner, Alexander; Sommer, Regina; Farnleitner, Andreas; Blaschke, Alfred Paul

    2015-04-01

    A good chemical and microbiological water quality is of great importance in riverbank filtration systems that are used as public water supplies. Water quality is ideally monitored frequently at the drinking water well using a steady pumping rate. Monitoring source water (like groundwater) however, can be more challenging. First of all, piezometers should be drilled in the correct layer of the aquifer. Secondly, the sampling design should include all preferred parameters (microbiological and chemical parameters) and should also take the hydrological conditions into account. In this study, we made use of different geophysical techniques (ERT and FDEM) to select the optimal placement of the piezometers. We also designed a sampling strategy which can be used to sample fecal indicators, biostability parameters, standard chemical parameters and a wide range of micropollutants. Several time series experiments were carried out in the study site Porous GroundWater Aquifer (PGWA) - an urban floodplain extending on the left bank of the river Danube downstream of the City of Vienna, Austria. The upper layer of the PGWA consist of silt and has a thickness from 1 to 6 meter. The underlying confined aquifer consists of sand and gravel and has a thickness of in between 3 and 15 meter. Hydraulic conductivities range from 5 x 10-2 m/s up to 5 x 10-5 m/s. Underneath the aquifer are alternating sand and clay/silt layers. As fecal markers Escherichia coli, enterococci and aerobic spores were measured. Biostability was measured using leucine incorporation. Additionally, several micropollutants and standard chemical parameters were measured. Results showed that physical and chemical parameters stayed stable in all monitoring wells during extended purging. A similar trend could be observed for E coli and enterococci. In the wells close to the river, aerobic spores and leucine incorporation decreased after 30 min. of pumping, whereas the well close to the backwater showed a different

  8. ACCF/AHA methodology for the development of quality measures for cardiovascular technology: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Performance Measures.

    PubMed

    Bonow, Robert O; Douglas, Pamela S; Buxton, Alfred E; Cohen, David J; Curtis, Jeptha P; Delong, Elizabeth; Drozda, Joseph P; Ferguson, T Bruce; Heidenreich, Paul A; Hendel, Robert C; Masoudi, Frederick A; Peterson, Eric D; Taylor, Allen J

    2011-09-27

    Consistent with the growing national focus on healthcare quality, the American College of Cardiology Foundation (ACCF) and the American Heart Association (AHA) have taken a leadership role over the past decade in developing measures of the quality of cardiovascular care by convening a joint ACCF/AHA Task Force on Performance Measures. The Task Force is charged with identifying the clinical topics appropriate for the development of performance measures and with assembling writing committees composed of clinical and methodological experts in collaboration with appropriate subspecialty societies. The Task Force has also created methodology documents that offer guidance in the development of process, outcome, composite, and efficiency measures. Cardiovascular performance measures using existing ACCF/AHA methodology are based on Class I or Class III guidelines recommendations, usually with Level A evidence. These performance measures, based on evidence-based ACCF/AHA guidelines, remain the most rigorous quality measures for both internal quality improvement and public reporting. However, many of the tools for diagnosis and treatment of cardiovascular disease involve advanced technologies, such as cardiac imaging, for which there are often no underlying guideline documents. Because these technologies affect the quality of cardiovascular care and also have the potential to contribute to cardiovascular health expenditures, there is a need for more critical assessment of the use of technology, including the development of quality and performance measures in areas in which guideline recommendations are absent. The evaluation of quality in the use of cardiovascular technologies requires consideration of multiple parameters that differ from other healthcare processes. The present document describes methodology for development of 2 new classes of quality measures in these situations, appropriate use measures and structure/safety measures. Appropriate use measures are based on

  9. Quality assessment of solar UV irradiance measured with array spectroradiometers

    NASA Astrophysics Data System (ADS)

    Egli, Luca; Gröbner, Julian; Hülsen, Gregor; Bachmann, Luciano; Blumthaler, Mario; Dubard, Jimmy; Khazova, Marina; Kift, Richard; Hoogendijk, Kees; Serrano, Antonio; Smedley, Andrew; Vilaplana, José-Manuel

    2016-04-01

    The reliable quantification of ultraviolet (UV) radiation at the earth's surface requires accurate measurements of spectral global solar UV irradiance in order to determine the UV exposure to human skin and to understand long-term trends in this parameter. Array spectroradiometers (ASRMs) are small, light, robust and cost-effective instruments, and are increasingly used for spectral irradiance measurements. Within the European EMRP ENV03 project "Solar UV", new devices, guidelines and characterization methods have been developed to improve solar UV measurements with ASRMs, and support to the end user community has been provided. In order to assess the quality of 14 end user ASRMs, a solar UV intercomparison was held on the measurement platform of the World Radiation Center (PMOD/WRC) in Davos, Switzerland, from 10 to 17 July 2014. The results of the blind intercomparison revealed that ASRMs, currently used for solar UV measurements, show a large variation in the quality of their solar UV measurements. Most of the instruments overestimate the erythema-weighted UV index - in particular at large solar zenith angles - due to stray light contribution in the UV-B range. The spectral analysis of global solar UV irradiance further supported the finding that the uncertainties in the UV-B range are very large due to stray light contribution in this wavelength range. In summary, the UV index may be detected by some commercially available ASRMs within 5 % compared to the world reference spectroradiometer, if well characterized and calibrated, but only for a limited range of solar zenith angles. Generally, the tested instruments are not yet suitable for solar UV measurements for the entire range between 290 and 400 nm under all atmospheric conditions.

  10. Quality assessment of solar UV irradiance measured with array spectroradiometers

    NASA Astrophysics Data System (ADS)

    Egli, L.; Gröbner, J.; Hülsen, G.; Bachmann, L.; Blumthaler, M.; Dubard, J.; Khazova, M.; Kift, R.; Hoogendijk, K.; Serrano, A.; Smedley, A. R. D.; Vilaplana, J.-M.

    2015-12-01

    The reliable quantification of ultraviolet (UV) radiation at the Earth's surface requires accurate measurements of spectral global solar UV irradiance in order to determine the UV exposure to human skin and to understand long-term trends in this parameter. Array spectroradiometers are small, light, robust and cost effective instruments and are increasingly used for spectral irradiance measurements. Within the European EMRP-ENV03 project "Solar UV", new devices, guidelines, and characterization methods have been developed to improve solar UV measurements with array spectroradiometers and support to the end-user community has been provided. In order to assess the quality of 14 end-user array spectroradiometers, a solar UV intercomparison was held on the measurement platform of the World Radiation Center (PMOD/WRC) in Davos, Switzerland, from 10 to 17 July 2014. The results of the intercomparison revealed that array spectroradiometers, currently used for solar UV measurements, show a large variation in the quality of their solar UV measurements. Most of the instruments overestimate the erythema weighted UV index - in particular at low solar zenith angles - due to stray light contribution in the UV-B range. The spectral analysis of global solar UV irradiance further supported the finding that the uncertainties in the UV-B range are very large due to stray light contribution in this wavelength range. In summary, the UV index may be detected by some commercially available array spectroradiometer within 5 % compared to the world reference spectroradiometer, if well characterized and calibrated, but only for a limited range or solar zenith angle. Generally, the tested instruments are not yet suitable for solar UV measurements for the entire range between 290 to 400 nm under all atmospheric conditions.

  11. Characterization of Argentine honeys on the basis of their mineral content and some typical quality parameters

    PubMed Central

    2014-01-01

    Background The levels of 19 elements (As, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, Se, Tl, U, V, Zn) from sixteen different Argentine production sites of unifloral [eucalyptus (Eucaliptus rostrata), chilca (Baccharis salicifolia), Algarrobo (Prosopis sp.), mistol (Ziziphus mistol) and citric] and multifloral honeys were measured with the aim to test the quality of the selected samples. Typical quality parameters of honeys were also determined (pH, sugar content, moisture). Mineral elements were determined by using inductively coupled plasma mass spectrometer (ICP-MS DRC). We also evaluated the suitability of honey as a possible biomonitor of environmental pollution. Thus, the sites were classified through cluster analysis (CA) and then pattern recognition methods such as Principal Component Analysis (PCA) and discriminant analysis (DA) were applied. Results Mean values for quality parameters were: pH, 4.12 and 3.81; sugar 82.1 and 82.0 °brix; moisture, 16.90 and 17.00% for unifloral and multifloral honeys respectively. The water content showed good maturity. Likewise, the other parameters confirmed the good quality of the honeys analysed. Potassium was quantitatively the most abundant metal, accounting for 92,5% of the total metal contents with an average concentration of 832.0 and 816.2 μg g-1 for unifloral and multifloral honeys respectively. Sodium was the second most abundant major metal in honeys with a mean value of 32.16 and 33.19 μg g-1 for unifloral and multifloral honeys respectively. Mg, Ca, Fe, Mn, Zn and Cu were present at low-intermediate concentrations. For the other 11 trace elements determined in this study (As, Be, Cd, Co, Cr, Ni, Pb, Se, Tl, U and V), the mean concentrations were very low or below of the LODs. The sites were classified through CA by using elements’ and physicochemical parameters data, then DA on the PCA factors was applied. Dendrograms identified three main groups. PCA explained 52.03% of the total variability

  12. Measurement system for 3-D foot coordinates and parameters

    NASA Astrophysics Data System (ADS)

    Liu, Guozhong; Li, Yunhui; Wang, Boxiong; Shi, Hui; Luo, Xiuzhi

    2008-12-01

    The 3-D foot-shape measurement system based on laser-line-scanning principle and the model of the measurement system were presented. Errors caused by nonlinearity of CCD cameras and caused by installation can be eliminated by using the global calibration method for CCD cameras, which based on nonlinear coordinate mapping function and the optimized method. A local foot coordinate system is defined with the Pternion and the Acropodion extracted from the boundaries of foot projections. The characteristic points can thus be located and foot parameters be extracted automatically by the local foot coordinate system and the related sections. Foot measurements for about 200 participants were conducted and the measurement results for male and female participants were presented. 3-D foot coordinates and parameters measurement makes it possible to realize custom-made shoe-making and shows great prosperity in shoe design, foot orthopaedic treatment, shoe size standardization, and establishment of a feet database for consumers.

  13. Traffic Data Quality Measurement : Final Report

    DOT National Transportation Integrated Search

    2004-09-15

    One of the foremost recommendations from the FHWA sponsored workshops on Traffic Data Quality (TDQ) in 2003 was a call for "guidelines and standards for calculating data quality measures." These guidelines and standards are expected to contain method...

  14. NEMA image quality phantom measurements and attenuation correction in integrated PET/MR hybrid imaging.

    PubMed

    Ziegler, Susanne; Jakoby, Bjoern W; Braun, Harald; Paulus, Daniel H; Quick, Harald H

    2015-12-01

    In integrated PET/MR hybrid imaging the evaluation of PET performance characteristics according to the NEMA standard NU 2-2007 is challenging because of incomplete MR-based attenuation correction (AC) for phantom imaging. In this study, a strategy for CT-based AC of the NEMA image quality (IQ) phantom is assessed. The method is systematically evaluated in NEMA IQ phantom measurements on an integrated PET/MR system. NEMA IQ measurements were performed on the integrated 3.0 Tesla PET/MR hybrid system (Biograph mMR, Siemens Healthcare). AC of the NEMA IQ phantom was realized by an MR-based and by a CT-based method. The suggested CT-based AC uses a template μ-map of the NEMA IQ phantom and a phantom holder for exact repositioning of the phantom on the systems patient table. The PET image quality parameters contrast recovery, background variability, and signal-to-noise ratio (SNR) were determined and compared for both phantom AC methods. Reconstruction parameters of an iterative 3D OP-OSEM reconstruction were optimized for highest lesion SNR in NEMA IQ phantom imaging. Using a CT-based NEMA IQ phantom μ-map on the PET/MR system is straightforward and allowed performing accurate NEMA IQ measurements on the hybrid system. MR-based AC was determined to be insufficient for PET quantification in the tested NEMA IQ phantom because only photon attenuation caused by the MR-visible phantom filling but not the phantom housing is considered. Using the suggested CT-based AC, the highest SNR in this phantom experiment for small lesions (<= 13 mm) was obtained with 3 iterations, 21 subsets and 4 mm Gaussian filtering. This study suggests CT-based AC for the NEMA IQ phantom when performing PET NEMA IQ measurements on an integrated PET/MR hybrid system. The superiority of CT-based AC for this phantom is demonstrated by comparison to measurements using MR-based AC. Furthermore, optimized PET image reconstruction parameters are provided for the highest lesion SNR in NEMA IQ phantom

  15. Issues in Measuring and Improving Health Care Quality

    PubMed Central

    Friedman, Maria A.

    1995-01-01

    This issue of the Health Care Financing Review focuses on issues and advances in measuring and improving the quality of care, particularly for Medicare and Medicaid beneficiaries. Discussions of quality-related topics are especially timely, given the growing and widespread interest in improving quality in the organization, financing, and delivery of health care services. This article has several purposes. The first is to provide a brief description of some of the causes underlying the growth of the health care quality movement; the second is to provide a contextual framework for discussion of some of the overarching themes that emerge in this issue. These themes include examining conceptual issues, developing quality measures for specific sites and populations, and creating or adapting data sets for quality-measurement purposes. PMID:10151882

  16. Content dependent selection of image enhancement parameters for mobile displays

    NASA Astrophysics Data System (ADS)

    Lee, Yoon-Gyoo; Kang, Yoo-Jin; Kim, Han-Eol; Kim, Ka-Hee; Kim, Choon-Woo

    2011-01-01

    Mobile devices such as cellular phones and portable multimedia player with capability of playing terrestrial digital multimedia broadcasting (T-DMB) contents have been introduced into consumer market. In this paper, content dependent image quality enhancement method for sharpness and colorfulness and noise reduction is presented to improve perceived image quality on mobile displays. Human visual experiments are performed to analyze viewers' preference. Relationship between the objective measures and the optimal values of image control parameters are modeled by simple lookup tables based on the results of human visual experiments. Content dependent values of image control parameters are determined based on the calculated measures and predetermined lookup tables. Experimental results indicate that dynamic selection of image control parameters yields better image quality.

  17. Cloud and Thermodynamic Parameters Retrieved from Satellite Ultraspectral Infrared Measurements

    NASA Technical Reports Server (NTRS)

    Zhou, Daniel K.; Smith, William L.; Larar, Allen M.; Liu, Xu; Taylor, Jonathan P.; Schluessel, Peter; Strow, L. Larrabee; Mango, Stephen A.

    2008-01-01

    Atmospheric-thermodynamic parameters and surface properties are basic meteorological parameters for weather forecasting. A physical geophysical parameter retrieval scheme dealing with cloudy and cloud-free radiance observed with satellite ultraspectral infrared sounders has been developed and applied to the Infrared Atmospheric Sounding Interferometer (IASI) and the Atmospheric InfraRed Sounder (AIRS). The retrieved parameters presented herein are from radiance data gathered during the Joint Airborne IASI Validation Experiment (JAIVEx). JAIVEx provided intensive aircraft observations obtained from airborne Fourier Transform Spectrometer (FTS) systems, in-situ measurements, and dedicated dropsonde and radiosonde measurements for the validation of the IASI products. Here, IASI atmospheric profile retrievals are compared with those obtained from dedicated dropsondes, radiosondes, and the airborne FTS system. The IASI examples presented here demonstrate the ability to retrieve fine-scale horizontal features with high vertical resolution from satellite ultraspectral sounder radiance spectra.

  18. Phosphatidylserine exposure on stored red blood cells as a parameter for donor-dependent variation in product quality.

    PubMed

    Dinkla, Sip; Peppelman, Malou; Van Der Raadt, Jori; Atsma, Femke; Novotný, Vera M J; Van Kraaij, Marian G J; Joosten, Irma; Bosman, Giel J C G M

    2014-04-01

    Exposure of phosphatidylserine on the outside of red blood cells contributes to recognition and removal of old and damaged cells. The fraction of phosphatidylserine-exposing red blood cells varies between donors, and increases in red blood cell concentrates during storage. The susceptibility of red blood cells to stress-induced phosphatidylserine exposure increases with storage. Phosphatidylserine exposure may, therefore, constitute a link between donor variation and the quality of red blood cell concentrates. In order to examine the relationship between storage parameters and donor characteristics, the percentage of phosphatidylserine-exposing red blood cells was measured in red blood cell concentrates during storage and in fresh red blood cells from blood bank donors. The percentage of phosphatidylserine-exposing red blood cells was compared with red blood cell susceptibility to osmotic stress-induced phosphatidylserine exposure in vitro, with the regular red blood cell concentrate quality parameters, and with the donor characteristics age, body mass index, haemoglobin level, gender and blood group. Phosphatidylserine exposure varies between donors, both on red blood cells freshly isolated from the blood, and on red blood cells in red blood cell concentrates. Phosphatidylserine exposure increases with storage time, and is correlated with stress-induced phosphatidylserine exposure. Increased phosphatidylserine exposure during storage was found to be associated with haemolysis and vesicle concentration in red blood cell concentrates. The percentage of phosphatidylserine-exposing red blood cells showed a positive correlation with the plasma haemoglobin concentration of the donor. The fraction of phosphatidylserine-exposing red blood cells is a parameter of red blood cell integrity in red blood cell concentrates and may be an indicator of red blood cell survival after transfusion. Measurement of phosphatidylserine exposure may be useful in the selection of donors and

  19. Dental Quality Measurement--A Practitioner Perspective.

    PubMed

    Amundson, Craig W

    2016-04-01

    This article reviews the HealthPartners Dental Group's experience with clinical quality measurement and provides information on the administrative infrastructure that supports measurement within the group. Some examples of the role measurement plays in operations and clinical practice are also reviewed.

  20. Evaluation of ride quality measurement procedures by subjective experiments using simulators

    NASA Technical Reports Server (NTRS)

    Klauder, L. T., Jr.; Clevenson, S. A.

    1975-01-01

    Since ride quality is, by definition, a matter of passenger response, there is need for a qualification procedure (QP) for establishing the degree to which any particular ride quality measurement procedure (RQMP) does correlate with passenger responses. Once established, such a QP will provide very useful guidance for optimal adjustment of the various parameters which any given RQMP contains. A QP is proposed based on use of a ride motion simulator and on test subject responses to recordings of actual vehicle motions. Test subject responses are used to determine simulator gain settings for the individual recordings such as to make all of the simulated rides equally uncomfortable to the test subjects. Simulator platform accelerations vs. time are recorded with each ride at its equal discomfort gain setting. The equal discomfort platform acceleration recordings are then digitzed.

  1. Estimation of distributional parameters for censored trace level water quality data: 2. Verification and applications

    USGS Publications Warehouse

    Helsel, Dennis R.; Gilliom, Robert J.

    1986-01-01

    Estimates of distributional parameters (mean, standard deviation, median, interquartile range) are often desired for data sets containing censored observations. Eight methods for estimating these parameters have been evaluated by R. J. Gilliom and D. R. Helsel (this issue) using Monte Carlo simulations. To verify those findings, the same methods are now applied to actual water quality data. The best method (lowest root-mean-squared error (rmse)) over all parameters, sample sizes, and censoring levels is log probability regression (LR), the method found best in the Monte Carlo simulations. Best methods for estimating moment or percentile parameters separately are also identical to the simulations. Reliability of these estimates can be expressed as confidence intervals using rmse and bias values taken from the simulation results. Finally, a new simulation study shows that best methods for estimating uncensored sample statistics from censored data sets are identical to those for estimating population parameters. Thus this study and the companion study by Gilliom and Helsel form the basis for making the best possible estimates of either population parameters or sample statistics from censored water quality data, and for assessments of their reliability.

  2. APPLICATION OF DATA QUALITY OBJECTIVES AND MEASUREMENT QUALITY OBJECTIVES TO RESEARCH PROJECTS

    EPA Science Inventory

    The paper assists systematic planning for research projects. It presents planning concepts in terms that have some utility for researchers. For example, measurement quality objectives are more familiar to researchers than data quality objectives because these quality criteria are...

  3. Quality parameters analysis of optical imaging systems with enhanced focal depth using the Wigner distribution function

    PubMed

    Zalvidea; Colautti; Sicre

    2000-05-01

    An analysis of the Strehl ratio and the optical transfer function as imaging quality parameters of optical elements with enhanced focal length is carried out by employing the Wigner distribution function. To this end, we use four different pupil functions: a full circular aperture, a hyper-Gaussian aperture, a quartic phase plate, and a logarithmic phase mask. A comparison is performed between the quality parameters and test images formed by these pupil functions at different defocus distances.

  4. Measurement of agricultural parameters using wireless sensor network (WSN)

    NASA Astrophysics Data System (ADS)

    Guaña-Moya, Javier; Sánchez-Almeida, Tarquino; Salgado-Reyes, Nelson

    2018-04-01

    The technological advances have allowed to create new applications in telecommunications, applying low power and reduced costs in their equipment, thus achieving the evolution of new wireless networks or also denominated Wireless Sensor Network. These technologies allow the generation of measurements and analysis of environmental parameter data and soil. Precision agriculture requires parameters for the improvement of production, obtained through WSN technologies. This research analyzes the climatic requirements and soil parameters in a rose plantation in a greenhouse at an altitude of 3,100 meters above sea level. In the present investigation, maximum parameters were obtained in the production of roses, which are in the optimum range of production, whereas the minimum parameters of temperature, humidity and luminosity, evidenced that these parameters can damage the plants, since temperatures less than 10 °C slow down the growth of the plant and allow the proliferation of diseases and fungi.

  5. Quality measurement for rhinosinusitis: a review from the Quality Improvement Committee of the American Rhinologic Society.

    PubMed

    Rudmik, Luke; Mattos, Jose; Schneider, John; Manes, Peter R; Stokken, Janalee K; Lee, Jivianne; Higgins, Thomas S; Schlosser, Rodney J; Reh, Douglas D; Setzen, Michael; Soler, Zachary M

    2017-09-01

    Measuring quality outcomes is an important prerequisite to improve quality of care. Rhinosinusitis represents a high value target to improve quality of care because it has a high prevalence of disease, large economic burden, and large practice variation. In this study we review the current state of quality measurement for management of both acute (ARS) and chronic rhinosinusitis (CRS). The major national quality metric repositories and clearinghouses were queried. Additional searches included the American Academy of Otolaryngology-Head and Neck Surgery database, PubMed, and Google to attempt to capture any additional quality metrics. Seven quality metrics for ARS and 4 quality metrics for CRS were identified. ARS metrics focused on appropriateness of diagnosis (n = 1), antibiotic prescribing (n = 4), and radiologic imaging (n = 2). CRS quality metrics focused on appropriateness of diagnosis (n = 1), radiologic imaging (n = 1), and measurement of patient quality of life (n = 2). The Physician Quality Reporting System (PQRS) currently tracks 3 ARS quality metrics and 1 CRS quality metric. There are no outcome-based rhinosinusitis quality metrics and no metrics that assess domains of safety, patient-centeredness, and timeliness of care. The current status of quality measurement for rhinosinusitis has focused primarily on the quality domain of efficiency and process measures for ARS. More work is needed to develop, validate, and track outcome-based quality metrics along with CRS-specific metrics. Although there has been excellent work done to improve quality measurement for rhinosinusitis, there remain major gaps and challenges that need to be considered during the development of future metrics. © 2017 ARS-AAOA, LLC.

  6. Impacts of different types of measurements on estimating unsaturated flow parameters

    NASA Astrophysics Data System (ADS)

    Shi, Liangsheng; Song, Xuehang; Tong, Juxiu; Zhu, Yan; Zhang, Qiuru

    2015-05-01

    This paper assesses the value of different types of measurements for estimating soil hydraulic parameters. A numerical method based on ensemble Kalman filter (EnKF) is presented to solely or jointly assimilate point-scale soil water head data, point-scale soil water content data, surface soil water content data and groundwater level data. This study investigates the performance of EnKF under different types of data, the potential worth contained in these data, and the factors that may affect estimation accuracy. Results show that for all types of data, smaller measurements errors lead to faster convergence to the true values. Higher accuracy measurements are required to improve the parameter estimation if a large number of unknown parameters need to be identified simultaneously. The data worth implied by the surface soil water content data and groundwater level data is prone to corruption by a deviated initial guess. Surface soil moisture data are capable of identifying soil hydraulic parameters for the top layers, but exert less or no influence on deeper layers especially when estimating multiple parameters simultaneously. Groundwater level is one type of valuable information to infer the soil hydraulic parameters. However, based on the approach used in this study, the estimates from groundwater level data may suffer severe degradation if a large number of parameters must be identified. Combined use of two or more types of data is helpful to improve the parameter estimation.

  7. Measurement properties of asthma-specific quality-of-life measures: protocol for a systematic review.

    PubMed

    Apfelbacher, Christian; Paudyal, Priya; Bülbül, Alpaslan; Smith, Helen

    2014-07-24

    Asthma is a frequent chronic inflammatory disease of the airways, and the assessment of health-related quality of life (HrQoL) is important in both research and routine care. Various asthma-specific measures of HrQoL exist but there is uncertainty which measures are best suited for use in research and routine care. Therefore, the aim of the proposed research is a comprehensive systematic assessment of the measurement properties of the existing measures that were developed to measure asthma-specific quality of life. This study is a systematic review of the measurement properties of asthma-specific measures of health-related quality of life. PubMed and Embase will be searched using a selection of relevant search terms. Eligible studies will be primary empirical studies evaluating, describing or comparing measurement properties of asthma-specific HRQL tools. Eligibility assessment and data abstraction will be performed independently by two reviewers. Evidence tables will be generated for study characteristics, instrument characteristics, measurement properties and interpretability. The quality of the measurement properties will be assessed using predefined criteria. Methodological quality of studies will be assessed using the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist. A best evidence synthesis will be undertaken if more than one study have investigated a particular measurement property. The proposed systematic review will produce a comprehensive assessment of measurement properties of existing measures of asthma-specific health-related quality of life. We also aim to derive recommendations in order to help researchers and practitioners alike in the choice of instrument. PROSPERO registration number: CRD42014010491.

  8. Commentary: measuring quality of care in osteoporosis.

    PubMed

    Silverman, Stuart L; Curtis, Jeffrey

    2013-12-01

    We know improving the quality of care in osteoporosis is an important goal. We have made some strides toward measuring quality of osteoporosis care, focusing on process measures regarding care that is provided. Unfortunately, improving care as measured by these process measures does not always yield improved outcomes. We need to hold health care providers and health care systems responsible not only for health care production but for production of health and well-being. However, there is a multiplicity of factors that will need to be considered to make this next step.

  9. [Comparative quality measurements part 3: funnel plots].

    PubMed

    Kottner, Jan; Lahmann, Nils

    2014-02-01

    Comparative quality measurements between organisations or institutions are common. Quality measures need to be standardised and risk adjusted. Random error must also be taken adequately into account. Rankings without consideration of the precision lead to flawed interpretations and enhances "gaming". Application of confidence intervals is one possibility to take chance variation into account. Funnel plots are modified control charts based on Statistical Process Control (SPC) theory. The quality measures are plotted against their sample size. Warning and control limits that are 2 or 3 standard deviations from the center line are added. With increasing group size the precision increases and so the control limits are forming a funnel. Data points within the control limits are considered to show common cause variation; data points outside special cause variation without the focus of spurious rankings. Funnel plots offer data based information about how to evaluate institutional performance within quality management contexts.

  10. Sound quality characteristics of refrigerator noise in real living environments with relation to psychoacoustical and autocorrelation function parameters.

    PubMed

    Sato, Shin-ichi; You, Jin; Jeon, Jin Yong

    2007-07-01

    Psychoacoustical and autocorrelation function (ACF) parameters were employed to describe the temporal fluctuations of refrigerator noise during starting, transition into/from the stationary phase and termination of operation. The temporal fluctuations of refrigerator noise include a click at start-up, followed by a rapid increase in volume, a change of pitch, and termination of the operation. Subjective evaluations of the noise of 24 different refrigerators were conducted in a real living environment. The relationship between objective measures and perceived noisiness was examined by multiple regression analysis. Sound quality indices were developed based on psychoacoustical and ACF parameters. The psychoacoustical parameters found to be important for evaluating noisiness in the stationary phase were loudness and roughness. The relationship between noisiness and ACF parameters shows that sound energy and its fluctuations are important for evaluating noisiness. Also, refrigerator sounds that had a fluctuation of pitch were rated as more annoying. The tolerance level for the starting phase of refrigerator noise was found to be 33 dBA, which is the level where 65% of the participants in the subjective tests were satisfied.

  11. Quality improvement in neurology: dementia management quality measures.

    PubMed

    Odenheimer, Germaine; Borson, Soo; Sanders, Amy E; Swain-Eng, Rebecca J; Kyomen, Helen H; Tierney, Samantha; Gitlin, Laura; Forciea, Mary Ann; Absher, John; Shega, Joseph; Johnson, Jerry

    2014-03-01

    Professional and advocacy organizations have long urged that dementia should be recognized and properly diagnosed. With the passage of the National Alzheimer's Project Act in 2011, an Advisory Council for Alzheimer's Research, Care, and Services was convened to advise the Department of Health and Human Services. In May 2012, the Council produced the first National Plan to address Alzheimer's disease, and prominent in its recommendations is a call for quality measures suitable for evaluating and tracking dementia care in clinical settings. Although other efforts have been made to set dementia care quality standards, such as those pioneered by RAND in its series Assessing Care of Vulnerable Elders (ACOVE), practitioners, healthcare systems, and insurers have not widely embraced implementation. This executive summary (full manuscript available at www.neurology.org) reports on a new measurement set for dementia management developed by an interdisciplinary Dementia Measures Work Group (DWG) representing the major national organizations and advocacy organizations concerned with the care of individuals with dementia. The American Academy of Neurology (AAN), the American Geriatrics Society, the American Medical Directors Association, the American Psychiatric Association, and the American Medical Association-convened Physician Consortium for Performance Improvement led this effort. The ACOVE measures and the measurement set described here apply to individuals whose dementia has already been identified and properly diagnosed. Although similar in concept to ACOVE, the DWG measurement set differs in several important ways; it includes all stages of dementia in a single measure set, calls for the use of functional staging in planning care, prompts the use of validated instruments in patient and caregiver assessment and intervention, highlights the relevance of using palliative care concepts to guide care before the advanced stages of illness, and provides evidence-based support

  12. ACCF/AHA methodology for the development of quality measures for cardiovascular technology: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Performance Measures.

    PubMed

    Bonow, Robert O; Douglas, Pamela S; Buxton, Alfred E; Cohen, David J; Curtis, Jeptha P; Delong, Elizabeth; Drozda, Joseph P; Ferguson, T Bruce; Heidenreich, Paul A; Hendel, Robert C; Masoudi, Frederick A; Peterson, Eric D; Taylor, Allen J

    2011-09-27

    Consistent with the growing national focus on healthcare quality, the American College of Cardiology Foundation (ACCF) and the American Heart Association (AHA) have taken a leadership role over the past decade in developing measures of the quality of cardiovascular care by convening a joint ACCF/AHA Task Force on Performance Measures. The Task Force is charged with identifying the clinical topics appropriate for the development of performance measures and with assembling writing committees composed of clinical and methodological experts in collaboration with appropriate subspecialty societies. The Task Force has also created methodology documents that offer guidance in the development of process, outcome, composite, and efficiency measures. Cardiovascular performance measures using existing ACCF/AHA methodology are based on Class I or Class III guidelines recommendations, usually with Level A evidence. These performance measures, based on evidence-based ACCF/AHA guidelines, remain the most rigorous quality measures for both internal quality improvement and public reporting. However, many of the tools for diagnosis and treatment of cardiovascular disease involve advanced technologies, such as cardiac imaging, for which there are often no underlying guideline documents. Because these technologies affect the quality of cardiovascular care and also have the potential to contribute to cardiovascular health expenditures, there is a need for more critical assessment of the use of technology, including the development of quality and performance measures in areas in which guideline recommendations are absent. The evaluation of quality in the use of cardiovascular technologies requires consideration of multiple parameters that differ from other healthcare processes. The present document describes methodology for development of 2 new classes of quality measures in these situations, appropriate use measures and structure/safety measures. Appropriate use measures are based on

  13. Probabilistic teleportation via multi-parameter measurements and partially entangled states

    NASA Astrophysics Data System (ADS)

    Wei, Jiahua; Shi, Lei; Han, Chen; Xu, Zhiyan; Zhu, Yu; Wang, Gang; Wu, Hao

    2018-04-01

    In this paper, a novel scheme for probabilistic teleportation is presented with multi-parameter measurements via a non-maximally entangled state. This is in contrast to the fact that the measurement kinds for quantum teleportation are usually particular in most previous schemes. The detail implementation producers for our proposal are given by using of appropriate local unitary operations. Moreover, the total success probability and classical information of this proposal are calculated. It is demonstrated that the success probability and classical cost would be changed with the multi-measurement parameters and the entanglement factor of quantum channel. Our scheme could enlarge the research range of probabilistic teleportation.

  14. DUQuE quality management measures: associations between quality management at hospital and pathway levels.

    PubMed

    Wagner, Cordula; Groene, Oliver; Thompson, Caroline A; Dersarkissian, Maral; Klazinga, Niek S; Arah, Onyebuchi A; Suñol, Rosa

    2014-04-01

    The assessment of integral quality management (QM) in a hospital requires measurement and monitoring from different perspectives and at various levels of care delivery. Within the DUQuE project (Deepening our Understanding of Quality improvement in Europe), seven measures for QM were developed. This study investigates the relationships between the various quality measures. It is a multi-level, cross-sectional, mixed-method study. As part of the DUQuE project, we invited a random sample of 74 hospitals in 7 countries. The quality managers of these hospitals were the main respondents. Furthermore, data of site visits of external surveyors assessing the participating hospitals were used. Three measures of QM at hospitals level focusing on integral systems (QMSI), compliance with the Plan-Do-Study-Act quality improvement cycle (QMCI) and implementation of clinical quality (CQII). Four measures of QM activities at care pathway level focusing on Specialized expertise and responsibility (SER), Evidence-based organization of pathways (EBOP), Patient safety strategies (PSS) and Clinical review (CR). Positive significant associations were found between the three hospitals level QM measures. Results of the relationships between levels were mixed and showed most associations between QMCI and department-level QM measures for all four types of departments. QMSI was associated with PSS in all types of departments. By using the seven measures of QM, it is possible to get a more comprehensive picture of the maturity of QM in hospitals, with regard to the different levels and across various types of hospital departments.

  15. Accuracy of the Microsoft Kinect for measuring gait parameters during treadmill walking.

    PubMed

    Xu, Xu; McGorry, Raymond W; Chou, Li-Shan; Lin, Jia-Hua; Chang, Chien-Chi

    2015-07-01

    The measurement of gait parameters normally requires motion tracking systems combined with force plates, which limits the measurement to laboratory settings. In some recent studies, the possibility of using the portable, low cost, and marker-less Microsoft Kinect sensor to measure gait parameters on over-ground walking has been examined. The current study further examined the accuracy level of the Kinect sensor for assessment of various gait parameters during treadmill walking under different walking speeds. Twenty healthy participants walked on the treadmill and their full body kinematics data were measured by a Kinect sensor and a motion tracking system, concurrently. Spatiotemporal gait parameters and knee and hip joint angles were extracted from the two devices and were compared. The results showed that the accuracy levels when using the Kinect sensor varied across the gait parameters. Average heel strike frame errors were 0.18 and 0.30 frames for the right and left foot, respectively, while average toe off frame errors were -2.25 and -2.61 frames, respectively, across all participants and all walking speeds. The temporal gait parameters based purely on heel strike have less error than the temporal gait parameters based on toe off. The Kinect sensor can follow the trend of the joint trajectories for the knee and hip joints, though there was substantial error in magnitudes. The walking speed was also found to significantly affect the identified timing of toe off. The results of the study suggest that the Kinect sensor may be used as an alternative device to measure some gait parameters for treadmill walking, depending on the desired accuracy level. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  16. [Structure Parameters and Quality Outcomes of Ambulant Home-care].

    PubMed

    Suhr, Ralf; Raeder, Kathrin; Kuntz, Simone; Strube-Lahmann, Sandra; Latendorf, Antje; Klingelhöfer-Noe, Jürgen; Lahmann, Nils

    2018-05-14

    So far, there are few data available on the changes of ambulant home-care in Germany over the last decades. Therefore, the aim of this research was to provide structure data on nursing personnel, funding, size, regional differences, and training needs of ambulant home-care services in Germany. In addition, a possible association between structure parameters and quality outcomes for pressure ulcer and malnutrition was investigated. In 2015, a multicenter cross-sectional study was conducted in home-care services in Germany. Structure data from 99 randomly selected home-care services as well as data on pressure ulcers and malnutrition of 903 care-dependent clients were analyzed. The median (<98 clients) was used as a cut-off to differentiate between small and large home-care services. From a cut-off of 20,000 inhabitants, a region was considered urban. The average prevalence for decubitus and malnutrition (BMI<20 Kg/m2) were determined for each home-care service, and possible associations with structure parameters were analyzed using a multiple linear regression model. The proportion of registered nurses in non-private (private) home-care services was 60.6% (52.3%). The proportion of employees with a 200- h basic qualification in nursing was higher in private (12.5 vs. 4.7%), small home-care services (14.0 vs. 5.8%) and in urban regions (11.5 vs 5.7%). In average, registered nurses working in small home-care services spent significantly more time per client than the ones working in large services (3.8 vs. 2.9 h/week). The highest need for further training was shown on the subjects of pain, medication and cognitive impairment. No statistically significant correlation could be found between the average decubitus prevalence and structure parameters. Only the association between malnutrition prevalence and the proportion of registered nurses was statistically significant. The present representative study provides structure data on nursing personnel, funding, size

  17. Measuring the Mathematical Quality of Instruction

    ERIC Educational Resources Information Center

    Journal of Mathematics Teacher Education, 2011

    2011-01-01

    In this article, we describe a framework and instrument for measuring the mathematical quality of mathematics instruction. In describing this framework, we argue for the separation of the "mathematical quality of instruction" (MQI), such as the absence of mathematical errors and the presence of sound mathematical reasoning, from pedagogical…

  18. Genetic parameters of egg quality traits in long-term pedigree recorded Japanese quail.

    PubMed

    Sari, M; Tilki, M; Saatci, M

    2016-08-01

    This study was conducted to determine the genetic parameters of internal and external quality traits of Japanese quail eggs. Two statistical models were used in the calculation of genetic parameters and variance components. While 286 eggs were used based on model 1, 1,524 eggs were used based on model 2. Genetic parameters of the first eggs were calculated with direct genetic effect included in the analysis as random factors by using model 1. Model 2 was used for all eggs (5 to 6 eggs from each hen for six rearing groups). As different from model 1, their permanent environmental effects were also included in the model 2. Heritability of egg weight, egg length, egg width, shape index, shell weight, shell thickness, and shell ratio among the external quality traits of the eggs was respectively found to be 0.44, 0.53, 0.51, 0.70, 0.19, 0.16, and 0.05, respectively, according to model 1. These values were found to be 0.46, 0.40, 0.74, 0.48, 0.60, 0.28, and 0.21, respectively, according to model 2. Yolk weight, yolk diameter, yolk height, yolk index, yolk ratio, albumen weight, albumen height, albumen ratio, and Haugh unit values among the internal quality traits of the egg were found to be 0.22, 0.32, 0.02, 0.16, 0.19, 0.34, 0.19, 0.17, and 0.17, respectively, according to model 1. These internal quality traits were found to be 0.27, 0.18, 0.38, 0.06, 0.20, 0.41, 0.15, 0.15, and 0.12, respectively, according to model 2. Consequently, in this study, strong genetic correlations were detected between albumen height and Haugh unit, and also between albumen height and albumen weight. Additionally, a high and positive correlation was observed between some yolk traits (yolk weight and diameter) and albumen traits (weight and height). All these genetic correlations can be used to improve egg quality with a selection according to albumen weight. © 2016 Poultry Science Association Inc.

  19. Comparison of Free-Breathing With Navigator-Triggered Technique in Diffusion Weighted Imaging for Evaluation of Small Hepatocellular Carcinoma: Effect on Image Quality and Intravoxel Incoherent Motion Parameters.

    PubMed

    Shan, Yan; Zeng, Meng-su; Liu, Kai; Miao, Xi-Yin; Lin, Jiang; Fu, Cai xia; Xu, Peng-ju

    2015-01-01

    To evaluate the effect on image quality and intravoxel incoherent motion (IVIM) parameters of small hepatocellular carcinoma (HCC) from choice of either free-breathing (FB) or navigator-triggered (NT) diffusion-weighted (DW) imaging. Thirty patients with 37 small HCCs underwent IVIM DW imaging using 12 b values (0-800 s/mm) with 2 sequences: NT, FB. A biexponential analysis with the Bayesian method yielded true diffusion coefficient (D), pseudodiffusion coefficient (D*), and perfusion fraction (f) in small HCCs and liver parenchyma. Apparent diffusion coefficient (ADC) was also calculated. The acquisition time and image quality scores were assessed for 2 sequences. Independent sample t test was used to compare image quality, signal intensity ratio, IVIM parameters, and ADC values between the 2 sequences; reproducibility of IVIM parameters, and ADC values between 2 sequences was assessed with the Bland-Altman method (BA-LA). Image quality with NT sequence was superior to that with FB acquisition (P = 0.02). The mean acquisition time for FB scheme was shorter than that of NT sequence (6 minutes 14 seconds vs 10 minutes 21 seconds ± 10 seconds P < 0.01). The signal intensity ratio of small HCCs did not vary significantly between the 2 sequences. The ADC and IVIM parameters from the 2 sequences show no significant difference. Reproducibility of D*and f parameters in small HCC was poor (BA-LA: 95% confidence interval, -180.8% to 189.2% for D* and -133.8% to 174.9% for f). A moderate reproducibility of D and ADC parameters was observed (BA-LA: 95% confidence interval, -83.5% to 76.8% for D and -74.4% to 88.2% for ADC) between the 2 sequences. The NT DW imaging technique offers no advantage in IVIM parameters measurements of small HCC except better image quality, whereas FB technique offers greater confidence in fitted diffusion parameters for matched acquisition periods.

  20. Quantifying the effect of air quality control measures during the 2010 Commonwealth Games at Delhi, India

    NASA Astrophysics Data System (ADS)

    Beig, Gufran; Chate, Dilip M.; Ghude, Sachin. D.; Mahajan, A. S.; Srinivas, R.; Ali, K.; Sahu, S. K.; Parkhi, N.; Surendran, D.; Trimbake, H. R.

    2013-12-01

    In 2010, the XIX Commonwealth Games (CWG-2010) were held in India for the first time at Delhi and involved 71 commonwealth nations and dependencies with more than 6000 athletes participating in 272 events. This was the largest international multi-sport event to be staged in India and strict emission controls were imposed during the games in order to ensure improved air quality for the participating athletes as a significant portion of the population in Delhi is regularly exposed to elevated levels of pollution. The air quality control measures ranged from vehicular and traffic controls to relocation of factories and reduction of power plant emissions. In order to understand the effects of these policy induced control measures, a network of air quality and weather monitoring stations was set-up across different areas in Delhi under the Government of India's System of Air quality Forecasting And Research (SAFAR) project. Simultaneous measurements of aerosols, reactive trace gases (e.g. NOx, O3, CO) and meteorological parameters were made before, during and after CWG-2010. Contrary to expectations, the emission controls implemented were not sufficient to reduce the pollutants, instead in some cases, causing an increase. The measured pollutants regularly exceeded the National Ambient Air Quality limits over the games period. The reasons for this increase are attributed to an underestimation of the required control measures, which resulted in inadequate planning. The results indicate that any future air quality control measures need to be well planned and strictly imposed in order to improve the air quality in Delhi, which affects a large population and is deteriorating rapidly. Thus, the presence of systematic high resolution data and realistic emission inventories through networks such as SAFAR will be directly useful for the future.

  1. Measuring Cosmological Parameters with Photometrically Classified Pan-STARRS Supernovae

    NASA Astrophysics Data System (ADS)

    Jones, David; Scolnic, Daniel; Riess, Adam; Rest, Armin; Kirshner, Robert; Berger, Edo; Kessler, Rick; Pan, Yen-Chen; Foley, Ryan; Chornock, Ryan; Ortega, Carolyn; Challis, Peter; Burgett, William; Chambers, Kenneth; Draper, Peter; Flewelling, Heather; Huber, Mark; Kaiser, Nick; Kudritzki, Rolf; Metcalfe, Nigel; Tonry, John; Wainscoat, Richard J.; Waters, Chris; Gall, E. E. E.; Kotak, Rubina; McCrum, Matt; Smartt, Stephen; Smith, Ken

    2018-01-01

    We use nearly 1,200 supernovae (SNe) from Pan-STARRS and ~200 low-z (z < 0.1) SNe Ia to measure cosmological parameters. Though most of these SNe lack spectroscopic classifications, in a previous paper we demonstrated that photometrically classified SNe can still be used to infer unbiased cosmological parameters by using a Bayesian methodology that marginalizes over core-collapse (CC) SN contamination. Our sample contains nearly twice as many SNe as the largest previous compilation of SNe Ia. Combining SNe with Cosmic Microwave Background (CMB) constraints from the Planck satellite, we measure the dark energy equation of state parameter w to be -0.986±0.058 (stat+sys). If we allow w to evolve with redshift as w(a) = w0 + wa(1-a), we find w0 = -0.923±0.148 and wa = -0.404±0.797. These results are consistent with measurements of cosmological parameters from the JLA and from a new analysis of 1049 spectroscopically confirmed SNe Ia (Scolnic et al. 2017). We try four different photometric classification priors for Pan-STARRS SNe and two alternate ways of modeling the CC SN contamination, finding that none of these variants gives a w that differs by more than 1% from the baseline measurement. The systematic uncertainty on w due to marginalizing over the CC SN contamination, σwCC = 0.019, is approximately equal to the photometric calibration uncertainty and is lower than the systematic uncertainty in the SN\\,Ia dispersion model (σwdisp = 0.024). Our data provide one of the best current constraints on w, demonstrating that samples with ~5% CC SN contamination can give competitive cosmological constraints when the contaminating distribution is marginalized over in a Bayesian framework.

  2. Evaluation of the Ecochemical Status of the Danube in Serbia in Terms of Water Quality Parameters

    PubMed Central

    Takić, Ljiljana; Mladenović-Ranisavljević, Ivana; Vuković, Milovan; Mladenović, Ilija

    2012-01-01

    The Danube is an international river passing partly through Serbia. The protection of the environment and sustainable use of water resources is a primary task that implies constant monitoring of the quality status and evaluation of ecochemical status of the water in the Danube basin. The investigation includes calculation of all-inclusive water quality by the Serbian water quality index (SWQI) method and an evaluation of eco-chemical status of the Danube water in terms of water quality parameters from the entry to the exit point along its course through Serbia in the year of 2009. The results show that the overall quality of the Danube water on the territory of Serbia corresponds to the descriptive indicator of “very good” water. According to the Council Directive75/440/EEC, the evaluation of the ecostatus, with slight deviation of individual parameters at Pančevo, corresponds to A1 category of the surface water quality intended for the abstraction of drinking water supplies in member states. PMID:22645471

  3. Standardization and quality control parameters for Muktā Bhasma (calcined pearl)

    PubMed Central

    Joshi, Namrata; Sharma, Khemchand; Peter, Hema; Dash, Manoj Kumar

    2015-01-01

    Background: Muktā Bhasma (MB) is a traditional Ayurvedic preparation for cough, breathlessness, and eye disorders and is a powerful cardiac tonic, mood elevator, and known to promote strength, intellect, and semen production. Objectives: The present research work was conducted to generate fingerprint for raw and processed MB for quality assessment and standardization using classical and other techniques. Setting and Design: Three samples of MB were prepared by purification (śodhana) of Muktā (pearl) followed by repeated calcinations (Māraṇa). Resultant product was subjected to organoleptic tests and Ayurvedic tests for quality control such as rekhāpūrṇatā, vāritaratva, and nirdhūmatva. Materials and Methods: For quality control, physicochemical parameters such as loss on drying, total ash value, acid insoluble ash, specific gravity, pH value, and other tests using techniques such as elemental analysis with energy dispersive X-ray analysis (EDAX), Structural study with powder X-ray diffraction, particle size with scanning electron microscopy (SEM) were carried out on raw Muktā, Śodhita Muktā, and triplicate batches of MB. Results: The study showed that the raw material Muktā was calcium carbonate in aragonite form, which on repeated calcinations was converted into a more stable calcite form. SEM studies revealed that in raw and purified materials the particles were found scattered and unevenly arranged in the range of 718.7–214.7 nm while in final product, uniformly arranged, stable, rod-shaped, and rounded particles with more agglomerates were observed in the range of 279.2–79.93 nm. EDAX analysis revealed calcium as a major ingredient in MB (average 46.32%) which increased gradually in the stages of processing (raw 34.11%, Śodhita 37.5%). Conclusion: Quality control parameters have been quantified for fingerprinting of MB prepared using a particular method. PMID:26600667

  4. Influence of Different Container Closure Systems and Capping Process Parameters on Product Quality and Container Closure Integrity (CCI) in GMP Drug Product Manufacturing.

    PubMed

    Mathaes, Roman; Mahler, Hanns-Christian; Roggo, Yves; Huwyler, Joerg; Eder, Juergen; Fritsch, Kamila; Posset, Tobias; Mohl, Silke; Streubel, Alexander

    2016-01-01

    Capping equipment used in good manufacturing practice manufacturing features different designs and a variety of adjustable process parameters. The overall capping result is a complex interplay of the different capping process parameters and is insufficiently described in literature. It remains poorly studied how the different capping equipment designs and capping equipment process parameters (e.g., pre-compression force, capping plate height, turntable rotating speed) contribute to the final residual seal force of a sealed container closure system and its relation to container closure integrity and other drug product quality parameters. Stopper compression measured by computer tomography correlated to residual seal force measurements.In our studies, we used different container closure system configurations from different good manufacturing practice drug product fill & finish facilities to investigate the influence of differences in primary packaging, that is, vial size and rubber stopper design on the capping process and the capped drug product. In addition, we compared two large-scale good manufacturing practice manufacturing capping equipment and different capping equipment settings and their impact on product quality and integrity, as determined by residual seal force.The capping plate to plunger distance had a major influence on the obtained residual seal force values of a sealed vial, whereas the capping pre-compression force and the turntable rotation speed showed only a minor influence on the residual seal force of a sealed vial. Capping process parameters could not easily be transferred from capping equipment of different manufacturers. However, the residual seal force tester did provide a valuable tool to compare capping performance of different capping equipment. No vial showed any leakage greater than 10(-8)mbar L/s as measured by a helium mass spectrometry system, suggesting that container closure integrity was warranted in the residual seal force range

  5. Effect of muscle type and frozen storage on the quality parameters of Iberian restructured meat preparations.

    PubMed

    Antequera, Teresa; Pérez-Palacios, Trinidad; Rodas, Elena; Rodríguez, Mar; Córdoba, Juan J

    2014-10-01

    The main objective of this study was to evaluate the effect of muscle type and frozen storage on the quality of restructured meat preparations from undervalued Iberian muscle to make use of meat from a high-quality and natural pig production system. The effect of two muscle types (i.e. white-glycolytic (W) and red-oxidative (R)) and frozen storage (lasting 0, 30, 60 and 90 days) on quality characteristics were assessed. Significant differences were found between the W and R Iberian restructured preparations in most physicochemical and some colour, texture and sensory traits, and in the fatty acid profile and oxidative measurements, suggesting that the R muscles are more suitable; however, the microbial contamination should be reduced. Frozen storage reduced but did not eliminate the initial microbial contamination, and it enhanced some quality traits in the Iberian restructured preparations, i.e. increased a* values, cohesiveness and juiciness and decreased adhesiveness and pastiness, without negatively affecting any parameter. Thus, frozen Iberian restructured preparations are recommended to be commercialized. In addition, the implementation or revision of Hazard Analysis and Critical Control Point is recommended to reduce microbial contamination. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  6. REMOTE SENSING MEASUREMENTS OF AEROSOL OPTICAL THICKNESS AND CORRELATION WITH IN-SITU AIR QUALITY PARAMETERS DURING A SMOKE HAZE EPISODE IN SOUTHEAST ASIA

    NASA Astrophysics Data System (ADS)

    Chew, B.; Salinas Cortijo, S. V.; Liew, S.

    2009-12-01

    Transboundary smoke haze due to biomass burning is a major environmental problem in Southeast Asia which has not only affected air quality in the source region, but also in the surrounding countries. Air quality monitoring stations and meteorological stations can provide valuable information on the concentrations of criteria pollutants such as sulphur dioxide, nitrogen oxide, carbon monoxide, ozone and particulate mass (PM10) as well as health advisory to the general public during the haze episodes. Characteristics of aerosol particles in the smoke haze such as the aerosol optical thickness (AOT), aerosol size distribution and Angstrom exponent are also measured or retrieved by sun-tracking photometers, such as those deployed in the world-wide AErosol RObotic NETwork (AERONET). However, due to the limited spatial coverage by the air quality monitoring stations and AERONET sites, it is difficult to study and monitor the spatial and temporal variability of the smoke haze during a biomass burning episode, especially in areas without ground-based instrumentation. As such, we combine the standard in-situ measurements of PM10 by air quality monitoring stations with the remote sensing imagery from the Moderate Resolution Imaging Spectroradiometer (MODIS) on board NASA's Terra and Aqua satellites. The columnar AOT is first derived from the MODIS images for regions where PM10 measurements are available. Empirical correlations between AOT and PM10 measurements are then established for 50 sites in both Malaysia and Singapore during the smoke haze episode in 2006. When available, vertical feature information from the Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observation (CALIPSO) is used to examine the validity of the correlations. Aloft transport of aerosols, which can weaken the correlations between AOT and PM10 measurements, is also identified by CALIPSO and taken into consideration for the analysis. With this integrated approach, we hope to enhance and

  7. Measured Plume Dispersion Parameters Over Water. Volume 1.

    DTIC Science & Technology

    1984-09-01

    meteorlogical parameters were continuously monitored at various locations. Tracer gas concentrations were measured by a variety of methods at...addition, this step added a header . to the data set containing a variety of averaged meteorlogical quantities. The basic procedure in this step was

  8. Kinetic Parameter Measurements in the MINERVE Reactor

    NASA Astrophysics Data System (ADS)

    Perret, Grégory; Geslot, Benoit; Gruel, Adrien; Blaise, Patrick; Di-Salvo, Jacques; De Izarra, Grégoire; Jammes, Christian; Hursin, Mathieu; Pautz, Andréas

    2017-01-01

    In the framework of an international collaboration, teams of the PSI and CEA research institutes measure the critical decay constant (α0 = β/A), delayed neutron fraction (β) and generation time (A) of the Minerve reactor using the Feynman-α, Power Spectral Density and Rossi-α neutron noise measurement techniques. These measurements contribute to the experimental database of kinetic parameters used to improve nuclear data files and validate modern methods in Monte Carlo codes. Minerve is a zero-power pool reactor composed of a central experimental test lattice surrounded by a large aluminum buffer and four high-enriched driver regions. Measurements are performed in three slightly subcritical configurations (-2 cents to -30 cents) using two high-efficiency 235U fission chambers in the driver regions. Measurement of α0 and β obtained by the two institutes and with the different techniques are consistent for the configurations envisaged. Slight increases of the β values are observed with the subcriticality level. Best estimate values are obtained with the Cross-Power Spectral Density technique at -2 cents, and are worth: β = 716.9±9.0 pcm, α0 = 79.0±0.6 s-1 and A = 90.7±1.4 μs. The kinetic parameters are predicted with MCNP5-v1.6 and TRIPOLI4.9 and the JEFF-3.1/3.1.1 and ENDF/B-VII.1 nuclear data libraries. The predictions for β and α0 overestimate the experimental results by 3-5% and 10-12%, respectively; that for A underestimate the experimental result by 6-7%. The discrepancies are suspected to come from the driven system nature of Minerve and the location of the detectors in the driver regions, which prevent accounting for the full reactor.

  9. Effect of intense short rainfall events on coastal water quality parameters from remote sensing data

    NASA Astrophysics Data System (ADS)

    Corbari, Chiara; Lassini, Fabio; Mancini, Marco

    2016-07-01

    Strong rainfall events, especially during summer, in small river basins cause spills in the sea that often compromise the quality of coastal waters. The goal of this paper is then to study the changes of coastal waters quality as a result of intense rainfall events during the bathing season through the use of remote sensing data. These analyses are performed at the outlets of small watersheds which are not usually affected by high sediment transport as in the case of large basins which are persistently affected by intense solid transport which does not allow retrieving a reliable correlation between rainfall events and water quality parameters. Four small watersheds in different Italian regions on the Mediterranean Sea are selected for this study. The remotely sensed parameters of turbidity, total suspend solids and secchi disk depth, are retrieved from MODIS data. Secchi disk depths are also compared to available ground data during the summer seasons between 2003 and 2006 showing good correlations. Then the spatial and temporal changes of these parameters are analyzed after intense short storm events. Increases of turbidity and total suspend solids are found to be around 35 NTU and 20 mg L-1 respectively depending on the intensity of the rainfall event and on the distance from the shoreline. Moreover the recovery of water quality after the rain event is reached after two or three days.

  10. Assesment life quality of familial Mediterranean fever patients by short form-36 and its relationship with disease parameters.

    PubMed

    Sahin, S; Yalcin, I; Senel, S; Ataseven, H; Uslu, Au; Yildirim, O; Semiz, M

    2013-04-01

    Familial Mediterranean fever is an auto-inflammatory disorder. Long term complications of the disease include decreased quality of life. The measurement of quality of life in the patients with chronic disease has become an important research topic during the last years. We aimed to evaluate life quality of the FMF patients by SF-36, and examine its relationship with the disease parameters. One hundred voluntary patients (69 female, 31 male) admitted to the rheumatology clinic were included in the study. The control group consisted of 100 healthy individuals. All subjects in the study were asked to complete SF-36 questionnaire. Age of onset of FMF, age at diagnosis, age at the beginning of colchicine therapy, number of attacks per month, family history of FMF and dialysis were inquired of patients with FMF. Disease severity was determined using the FMF severity score. The mean age of the patient group was 31±12 and that of the control group was 29±9. Sixty-nine patients (69%) were female, and 31 patients were male (31%) in both groups. The mean scores of the physical function, physical role function, emotional role function, mental health, and general health parameters of the patients were statistically significantly lower than those of healthy volunteers (p < 0.05). The difference in social function and vitality between two groups was found to be insignificant (p > 0.05). We have shown that FMF had a negative impact on SF-36. FMF reduces quality of life both in physical and mental dimensions.

  11. Main Parameters of Soil Quality and it's Management Under Changing Climate

    NASA Astrophysics Data System (ADS)

    László Phd, M., ,, Dr.

    2009-04-01

    byproducts and atmospheric deposition; 4. storing and cycling nutrients and other elements within the earth's biosphere; and 5. providing support of socioeconomic structures and protection for archeological treasures associated with human habitation. No soil is likely to successfully provide all of these functions, some of which occur in natural ecosystems and some of which are the result of human modification. We can summarize by saying that soil quality depends on the extent to which soil functions to benefit humans. Thus, for food production or mediation of contamination, soil quality means the extent to which a soil fulfills the role we have defined for it. Within agriculture, high quality equates to maintenance of high productivity without significant soil or environmental degradation. The Glossary of Soil Science terms produced by the Soil Science Society of America (1996) states that soil quality is an inherent attribute of a soil that is inferred from soil characteristics or indirect observations. To proceed from a dictionary definition to a measure of soil quality, a minimum dataset (MDS) of soil characteristics that represents soil quality must be selected and quantified (Papendick et al., 1995). The MDS may include biological, chemical or physical soil characteristics [Organic matter (OM), Aggregation (A), Bulk density (BD), Depth to hardpan (DH), Electrical conductivity (EC), Fertility (F), Respiration (R), pH, Soil test (ST), Yield (Y), Infiltration (I), Mineralizable nitrogen potential (MNP), Water holding capacity (WHC)]. For agriculture, the measurement of properties should lead to a relatively simple and accurate way to rank soils based on potential plant production without soil degradation. Unfortunately, commonly identified soil quality parameters may not correlate well with yield (Reganold, 1988). In the next section, we consider these four points concerning the selection and quantification of soil characteristics: 1. soil characteristics may be desirable

  12. Prognostic Value of National Comprehensive Cancer Network Lung Cancer Resection Quality Parameters

    PubMed Central

    Osarogiagbon, Raymond U.; Ray, Meredith A.; Faris, Nicholas R.; Div, M.; Smeltzer, Matthew P.; Stat, M.; Fehnel, Carrie; Houston-Harris, Cheryl; Signore, Raymond S.; McHugh, Laura M.; Levy, Paul; Wiggins, Lynn; Sachdev, Vishal; Robbins, Edward T.

    2017-01-01

    Background The National Comprehensive Cancer Network (NCCN) surgical resection guidelines for non-small-cell lung cancer (NSCLC) recommend anatomic resection, negative margins, examination of hilar/intrapulmonary lymph nodes, and examination of 3 or more mediastinal nodal stations. We examined the survival impact of these guidelines. Methods Population-based observational study using patient-level data from all curative-intent NSCLC resections from 2004–2013 at 11 institutions in 4 contiguous Dartmouth Hospital Referral Regions in 3 US states. We used an adjusted Cox proportional hazards model to assess the overall survival impact of attaining NCCN guidelines. Results Of 2,429 eligible resections,91% were anatomic, 94% had negative margins, 51% sampled hilar nodes, and 26% examined three or more mediastinal nodal stations. Only 17% of resections met all four criteria, however there was a significant increasing trend from 2% in 2004 to 39% in 2013 (p<0.001). Compared to patients whose surgery missed one or more parameters, the hazard ratio for patients whose surgery met all four criteria was 0.71 (95% confidence interval: 0.59–0.86, p<0.001). Margin status and the nodal staging parameters were most strongly linked with survival. Conclusions Attainment of NCCN surgical quality guidelines was low, but improving, over the past decade in this cohort from a high lung cancer mortality region of the US. The NCCN quality criteria, especially the nodal examination criteria, were strongly associated with survival. The quality of nodal examination should be a focus of quality improvement in NSCLC care. PMID:28366464

  13. A Case Study Showing Parameters Affecting the Quality of Education: Faculty Perspective

    ERIC Educational Resources Information Center

    Kumari, Neeraj

    2014-01-01

    The study aims to examine the faculty members' perspective (age Wise, Gender Wise and Work Experience wise) of parameters affecting the quality of education in an affiliated Undergraduate Engineering Institution in Haryana. It is a descriptive type of research. The data has been collected with the help of 'Questionnaire Based Survey'. The sample…

  14. Quality Measurement in Early Childhood Settings

    ERIC Educational Resources Information Center

    Zaslow, Martha, Ed.; Martinez-Beck, Ivelisse, Ed.; Tout, Kathryn, Ed.; Halle, Tamara, Ed.

    2011-01-01

    What constitutes quality in early childhood settings, and how can it best be measured with today's widely used tools and promising new approaches? Find authoritative answers in this book, a must-have for high-level administrators and policymakers as more and more states adopt early childhood Quality Rating and Improvement Systems. The most…

  15. Genetic and phenotypic parameters for carcass and meat quality traits in commercial crossbred pigs.

    PubMed

    Miar, Y; Plastow, G S; Moore, S S; Manafiazar, G; Charagu, P; Kemp, R A; Van Haandel, B; Huisman, A E; Zhang, C Y; McKay, R M; Bruce, H L; Wang, Z

    2014-07-01

    Pork quality and carcass characteristics are now being integrated into swine breeding objectives because of their economic value. Understanding the genetic basis for these traits is necessary for this to be accomplished. The objective of this study was to estimate phenotypic and genetic parameters for carcass and meat quality traits in 2 Canadian swine populations. Data from a genomic selection study aimed at improving meat quality with a mating system involving hybrid Landrace × Large White and Duroc pigs were used to estimate heritabilities and phenotypic and genetic correlations among them. Data on 2,100 commercial crossbred pigs for meat quality and carcass traits were recorded with pedigrees compromising 9,439 animals over 15 generations. Significant fixed effects (company, sex, and slaughter batch), covariates (cold carcass weight and slaughter age), and random additive and common litter effects were fitted in the models. A series of pairwise bivariate analyses were implemented in ASReml to estimate phenotypic and genetic parameters. Heritability estimates (±SE) for carcass traits were moderate to high and ranged from 0.22 ± 0.08 for longissimus dorsi muscle area to 0.63 ± 0.04 for trimmed ham weight, except for firmness, which was low. Heritability estimates (±SE) for meat quality traits varied from 0.10 ± 0.04 to 0.39 ± 0.06 for the Minolta b* of ham quadriceps femoris muscle and shear force, respectively. Generally, most of the genetic correlations were significant (P < 0.05) and ranged from low (0.18 ± 0.07) to high (-0.97 ± 0.35). There were high negative genetic correlations between drip loss with pH and shear force and a positive correlation with cooking loss. Genetic correlations between carcass weight (both hot and cold) with carcass marbling were highly positive. It was concluded that selection for increasing primal and subprimal cut weights with better pork quality may be possible. Furthermore, the use of pH is confirmed as an indicator

  16. Effects of environmental and water quality parameters on the functioning of copepod assemblages in tropical estuaries

    NASA Astrophysics Data System (ADS)

    Araujo, Adriana V.; Dias, Cristina O.; Bonecker, Sérgio L. C.

    2017-07-01

    We examined changes in the functioning of copepod assemblages with increasing pollution in estuaries, using sampling standardization of the salinity range to enable comparisons. Copepod assemblages were analyzed in four southeast Brazilian estuaries with different water quality levels and hydrodynamic characteristics over two years. We obtained mesozooplankton samples together with environmental and water quality parameters in the estuaries, every two months under predetermined salinities ranging from 15 to 25. The values of parameters, except species size, associated with the functioning of the copepod assemblages (biomass, productivity, and turnover rate) did not differ among estuaries. However, in the more polluted estuaries, the biomass and productivity of copepod assemblages of mesozooplankton were negatively correlated with concentration of pollution indicator parameters. Conversely, in the less polluted estuaries some degree of enrichment still seems to increase the system biomass and productivity, as these parameters were inversely related to indicators of improved water quality. The pollution level of estuaries distorted the relationship between temperature and the efficiency of converting energy to organic matter. In the less polluted estuaries, the relationship between turnover rate and temperature was over 70%, while in the most polluted estuaries, this relationship was only approximately 50%. Our results demonstrated that the functioning of assemblages in the estuaries was affected differently by increasing pollution depending on the water quality level of the system. Thus, investigating the functioning of assemblages can be a useful tool for the analysis of estuarine conditions.

  17. Effect of dietary plant extract on meat quality and sensory parameters of meat from Equidae.

    PubMed

    Rossi, Raffaella; Ratti, Sabrina; Pastorelli, Grazia; Maghin, Federica; Martemucci, Giovanni; Casamassima, Donato; D'Alessandro, Angela Gabriella; Corino, Carlo

    2017-11-01

    Plant extracts as Lippia spp. have been proven antioxidant properties. Recent studies have been shown that dietary supplementation with plant extracts is able to enhance meat quality parameters. Studies regarding meat quality in Equidae are limited. The effect of dietary plant extract (PE), containing verbascoside, on meat quality, oxidative stability and sensory parameters of Longissimus Lumborum (LL) muscle in Equidae was studied. Dietary treatment did not affect (P > 0.05) pH, colour indices and chemical parameters of muscle in both donkey and horse. Dietary PE improved (P < 0.01) oxidative stability in donkey muscle during refrigerated storage. Sensory characteristics of LL muscle were positively affected (P < 0.05) by dietary PE in both donkey and horse. In particular, colour, taste and texture were enhanced in LL muscle from animals fed PE. Oxidative stability was lower (P < 0.05) in LL muscle of horse than that of donkey. Dietary plant extract, containing verbascoside, can be considered as a natural source of antioxidants, and is also able to improve oxidative stability of donkey meat and to affect the sensory attributes of Equidae meat. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  18. Interpolation of Regional Groundwater Quality Parameters With Categorical and Real-Valued Secondary Information in the State of Baden-Württemberg, Germany

    NASA Astrophysics Data System (ADS)

    Haslauer, C. P.; Allmendinger, M.; Gnann, S.; Heisserer, T.; Bárdossy, A.

    2017-12-01

    The basic problem of geostatistics is to estimate the primary variable (e.g. groundwater quality, nitrate) at an un-sampled location based on point measurements at locations in the vicinity. Typically, models are being used that describe the spatial dependence based on the geometry of the observation network. This presentation demonstrates methods that take the following properties additionally into account: the statistical distribution of the measurements, a different degree of dependence in different quantiles, censored measurements, the composition of categorical additional information in the neighbourhood (exhaustive secondary information), and the spatial dependence of a dependent secondary variable, possibly measured with a different observation network (non-exhaustive secondary data). Two modelling approaches are demonstrated individually and combined: The non-stationarity in the marginal distribution is accounted for by locally mixed distribution functions that depend on the composition of the categorical variable in the neighbourhood of each interpolation location. This methodology is currently being implemented for operational use at the environmental state agency of Baden-Württemberg. An alternative to co-Kriging in copula space with an arbitrary number of secondary parameters is presented: The method performs better than traditional techniques if the primary variable is undersampled and does not produce erroneous negative estimates. Even more, the quality of the uncertainty estimates is much improved. The worth of the secondary information is thoroughly evaluated. The improved geostatistical hydrogeological models are being analyzed using measurements of a large observation network ( 2500 measurement locations) in the state of Baden-Württemberg ( 36.000 km2). Typical groundwater quality parameters such as nitrate, chloride, barium, antrazine, and desethylatrazine are being assessed, cross-validated, and compared with traditional geostatistical methods

  19. Parameter Trade Studies For Coherent Lidar Wind Measurements of Wind from Space

    NASA Technical Reports Server (NTRS)

    Kavaya, Michael J.; Frehlich, Rod G.

    2007-01-01

    The design of an orbiting wind profiling lidar requires selection of dozens of lidar, measurement scenario, and mission geometry parameters; in addition to prediction of atmospheric parameters. Typical mission designs do not include a thorough trade optimization of all of these parameters. We report here the integration of a recently published parameterization of coherent lidar wind velocity measurement performance with an orbiting coherent wind lidar computer simulation; and the use of these combined tools to perform some preliminary parameter trades. We use the 2006 NASA Global Wind Observing Sounder mission design as the starting point for the trades.

  20. Prediction of harmful water quality parameters combining weather, air quality and ecosystem models with in situ measurement

    EPA Science Inventory

    The ability to predict water quality in lakes is important since lakes are sources of water for agriculture, drinking, and recreational uses. Lakes are also home to a dynamic ecosystem of lacustrine wetlands and deep waters. They are sensitive to pH changes and are dependent on d...

  1. COUPLING HYPERSPECTRAL REMOTE SENSING WITH FIELD SPECTROMETRY TO MONITOR INLAND WATER QUALITY PARAMETERS

    EPA Science Inventory

    Visible to near-infrared, airborne hyperspectral data were successfully used to estimate water quality parameters such as chlorophyll a, turbidity and total phosphorus from the Great Miami River, Ohio. During the summer of 1999, spectral data were collected with a hand-held fiel...

  2. Utilizing Operational and Improved Remote Sensing Measurements to Assess Air Quality Monitoring Model Forecasts

    NASA Astrophysics Data System (ADS)

    Gan, Chuen-Meei

    Air quality model forecasts from Weather Research and Forecast (WRF) and Community Multiscale Air Quality (CMAQ) are often used to support air quality applications such as regulatory issues and scientific inquiries on atmospheric science processes. In urban environments, these models become more complex due to the inherent complexity of the land surface coupling and the enhanced pollutants emissions. This makes it very difficult to diagnose the model, if the surface parameter forecasts such as PM2.5 (particulate matter with aerodynamic diameter less than 2.5 microm) are not accurate. For this reason, getting accurate boundary layer dynamic forecasts is as essential as quantifying realistic pollutants emissions. In this thesis, we explore the usefulness of vertical sounding measurements on assessing meteorological and air quality forecast models. In particular, we focus on assessing the WRF model (12km x 12km) coupled with the CMAQ model for the urban New York City (NYC) area using multiple vertical profiling and column integrated remote sensing measurements. This assessment is helpful in probing the root causes for WRF-CMAQ overestimates of surface PM2.5 occurring both predawn and post-sunset in the NYC area during the summer. In particular, we find that the significant underestimates in the WRF PBL height forecast is a key factor in explaining this anomaly. On the other hand, the model predictions of the PBL height during daytime when convective heating dominates were found to be highly correlated to lidar derived PBL height with minimal bias. Additional topics covered in this thesis include mathematical method using direct Mie scattering approach to convert aerosol microphysical properties from CMAQ into optical parameters making direct comparisons with lidar and multispectral radiometers feasible. Finally, we explore some tentative ideas on combining visible (VIS) and mid-infrared (MIR) sensors to better separate aerosols into fine and coarse modes.

  3. Measuring Two Key Parameters of H3 Color Centers in Diamond

    NASA Technical Reports Server (NTRS)

    Roberts, W. Thomas

    2005-01-01

    A method of measuring two key parameters of H3 color centers in diamond has been created as part of a continuing effort to develop tunable, continuous-wave, visible lasers that would utilize diamond as the lasing medium. (An H3 color center in a diamond crystal lattice comprises two nitrogen atoms substituted for two carbon atoms bonded to a third carbon atom. H3 color centers can be induced artificially; they also occur naturally. If present in sufficient density, they impart a yellow hue.) The method may also be applicable to the corresponding parameters of other candidate lasing media. One of the parameters is the number density of color centers, which is needed for designing an efficient laser. The other parameter is an optical-absorption cross section, which, as explained below, is needed for determining the number density. The present method represents an improvement over prior methods in which optical-absorption measurements have been used to determine absorption cross sections or number densities. Heretofore, in order to determine a number density from such measurements, it has been necessary to know the applicable absorption cross section; alternatively, to determine the absorption cross section from such measurements, it has been necessary to know the number density. If, as in this case, both the number density and the absorption cross section are initially unknown, then it is impossible to determine either parameter in the absence of additional information.

  4. Health-related quality-of-life parameters as independent prognostic factors in advanced or metastatic bladder cancer.

    PubMed

    Roychowdhury, D F; Hayden, A; Liepa, A M

    2003-02-15

    This retrospective analysis examined prognostic significance of health-related quality-of-life (HRQoL) parameters combined with baseline clinical factors on outcomes (overall survival, time to progressive disease, and time to treatment failure) in bladder cancer. Outcome and HRQoL (European Organization for Research and Treatment of Cancer Quality of Life Questionnaire C30) data were collected prospectively in a phase III study assessing gemcitabine and cisplatin versus methotrexate, vinblastine, doxorubicin, and cisplatin in locally advanced or metastatic bladder cancer. Prespecified baseline clinical factors (performance status, tumor-node-metastasis staging, visceral metastases [VM], alkaline phosphatase [AP] level, number of metastatic sites, prior radiotherapy, disease measurability, sex, time from diagnosis, and sites of disease) and selected HRQoL parameters (global QoL; all functional scales; symptoms: pain, fatigue, insomnia, dyspnea, anorexia) were evaluated using Cox's proportional hazards model. Factors with individual prognostic value (P <.05) on outcomes in univariate models were assessed for joint prognostic value in a multivariate model. A final model was developed using a backward selection strategy. Patients with baseline HRQoL were included (364 of 405, 90%). The final model predicted longer survival with low/normal AP levels, no VM, high physical functioning, low role functioning, and no anorexia. Positive prognostic factors for time to progressive disease were good performance status, low/normal AP levels, no VM, and minimal fatigue; for time to treatment failure, they were low/normal AP levels, minimal fatigue, and no anorexia. Global QoL was a significant predictor of outcome in univariate analyses but was not retained in the multivariate model. HRQoL parameters are independent prognostic factors for outcome in advanced bladder cancer; their prognostic importance needs further evaluation.

  5. Optical spectral signatures of liquids by means of fiber optic technology for product and quality parameter identification

    NASA Astrophysics Data System (ADS)

    Mignani, A. G.; Ciaccheri, L.; Mencaglia, A. A.; Diaz-Herrera, N.; Garcia-Allende, P. B.; Ottevaere, H.; Thienpont, H.; Attilio, C.; Cimato, A.; Francalanci, S.; Paccagnini, A.; Pavone, F. S.

    2009-01-01

    Absorption spectroscopy in the wide 200-1700 nm spectral range is carried out by means of optical fiber instrumentation to achieve a digital mapping of liquids for the prediction of important quality parameters. Extra virgin olive oils from Italy and lubricant oils from turbines with different degrees of degradation were considered as "case studies". The spectral data were processed by means of multivariate analysis so as to obtain a correlation to quality parameters. In practice, the wide range absorption spectra were considered as an optical signature of the liquids from which to extract product quality information. The optical signatures of extra virgin olive oils were used to predict the content of the most important fatty acids. The optical signatures of lubricant oils were used to predict the concentration of the most important parameters for indicating the oil's degree of degradation, such as TAN, JOAP anti-wear index, and water content.

  6. Dyes assay for measuring physicochemical parameters.

    PubMed

    Moczko, Ewa; Meglinski, Igor V; Bessant, Conrad; Piletsky, Sergey A

    2009-03-15

    A combination of selective fluorescent dyes has been developed for simultaneous quantitative measurements of several physicochemical parameters. The operating principle of the assay is similar to electronic nose and tongue systems, which combine nonspecific or semispecific elements for the determination of diverse analytes and chemometric techniques for multivariate data analysis. The analytical capability of the proposed mixture is engendered by changes in fluorescence signal in response to changes in environment such as pH, temperature, ionic strength, and presence of oxygen. The signal is detected by a three-dimensional spectrofluorimeter, and the acquired data are processed using an artificial neural network (ANN) for multivariate calibration. The fluorescence spectrum of a solution of selected dyes allows discreet reading of emission maxima of all dyes composing the mixture. The variations in peaks intensities caused by environmental changes provide distinctive fluorescence patterns which can be handled in the same way as the signals collected from nose/tongue electrochemical or piezoelectric devices. This optical system opens possibilities for rapid, inexpensive, real-time detection of a multitude of physicochemical parameters and analytes of complex samples.

  7. Information quality measurement of medical encoding support based on usability.

    PubMed

    Puentes, John; Montagner, Julien; Lecornu, Laurent; Cauvin, Jean-Michel

    2013-12-01

    Medical encoding support systems for diagnoses and medical procedures are an emerging technology that begins to play a key role in billing, reimbursement, and health policies decisions. A significant problem to exploit these systems is how to measure the appropriateness of any automatically generated list of codes, in terms of fitness for use, i.e. their quality. Until now, only information retrieval performance measurements have been applied to estimate the accuracy of codes lists as quality indicator. Such measurements do not give the value of codes lists for practical medical encoding, and cannot be used to globally compare the quality of multiple codes lists. This paper defines and validates a new encoding information quality measure that addresses the problem of measuring medical codes lists quality. It is based on a usability study of how expert coders and physicians apply computer-assisted medical encoding. The proposed measure, named ADN, evaluates codes Accuracy, Dispersion and Noise, and is adapted to the variable length and content of generated codes lists, coping with limitations of previous measures. According to the ADN measure, the information quality of a codes list is fully represented by a single point, within a suitably constrained feature space. Using one scheme, our approach is reliable to measure and compare the information quality of hundreds of codes lists, showing their practical value for medical encoding. Its pertinence is demonstrated by simulation and application to real data corresponding to 502 inpatient stays in four clinic departments. Results are compared to the consensus of three expert coders who also coded this anonymized database of discharge summaries, and to five information retrieval measures. Information quality assessment applying the ADN measure showed the degree of encoding-support system variability from one clinic department to another, providing a global evaluation of quality measurement trends. Copyright © 2013

  8. Quality measures and assurance for AI (Artificial Intelligence) software

    NASA Technical Reports Server (NTRS)

    Rushby, John

    1988-01-01

    This report is concerned with the application of software quality and evaluation measures to AI software and, more broadly, with the question of quality assurance for AI software. Considered are not only the metrics that attempt to measure some aspect of software quality, but also the methodologies and techniques (such as systematic testing) that attempt to improve some dimension of quality, without necessarily quantifying the extent of the improvement. The report is divided into three parts Part 1 reviews existing software quality measures, i.e., those that have been developed for, and applied to, conventional software. Part 2 considers the characteristics of AI software, the applicability and potential utility of measures and techniques identified in the first part, and reviews those few methods developed specifically for AI software. Part 3 presents an assessment and recommendations for the further exploration of this important area.

  9. Advancing the use of community pharmacy quality measures: a qualitative study.

    PubMed

    Shiyanbola, Olayinka O; Mort, Jane R; Lyons, Kayley

    2013-01-01

    To describe consumers' ability to interpret pharmacy quality measures data presented in a report card, to examine the tools that consumers require to interpret the information available in a pharmacy quality report card, and to determine whether pharmacy quality measures influence consumers' choice of a pharmacy. Qualitative study. Three semistructured focus groups conducted in a private meeting space at a public library in Sioux Falls, SD, from April 2011 to May 2011. 29 laypeople. Participants' skills interpreting and using pharmacy quality information were examined based on mock report cards containing the Pharmacy Quality Alliance (PQA) quality measures. Consumer perceptions of pharmacy quality data. Participants reported difficulty understanding quality measures because of knowledge deficits. They wanted supportive resources on drug class of their medications to help them understand the measures. Participants had different opinions on whether their pharmacies should be compared with other pharmacies based on specific quality measures. For example, they favored the use of drug-drug interactions as a quality measure for comparing pharmacies, while medication adherence was deemed of limited use for comparison. Participants stated that pharmacy report cards would be useful information but would not prompt a change in pharmacy. However, participants perceived that this information would be useful in selecting a new pharmacy. The results suggest that consumers require simplification of PQA quality measures and supportive resources to interpret the measures. Consumers may favor certain quality measures based on their perception of the role of the pharmacist. Education is required before full use of this quality-of-care information can be realized.

  10. The evolving landscape of quality measurement for heart failure

    PubMed Central

    Fitzgerald, Ashley A.; Allen, Larry A.; Masoudi, Frederick A.

    2013-01-01

    Heart failure (HF) is a major cause of mortality and morbidity, representing a leading cause of death and hospitalization among U.S. Medicare beneficiaries. Advances in science have generated effective interventions to reduce adverse outcomes in HF, particularly in patients with reduced left ventricular ejection fraction. Unfortunately, effective therapies for heart failure are often not utilized in an effective, safe, timely, equitable, patient-centered, and efficient manner. Further, the risk of adverse outcomes for HF remains high. The last decades have witnessed the growth of efforts to measure and improve the care and outcomes of patients with HF. This paper will review the evolution of quality measurement for HF, including a brief history of quality measurement in medicine; the measures that have been employed to characterize quality in heart failure; how the measures are obtained; how measures are employed; and present and future challenges surrounding quality measurement in heart failure. PMID:22548579

  11. Multidimensional correlation among plan complexity, quality and deliverability parameters for volumetric-modulated arc therapy using canonical correlation analysis.

    PubMed

    Shen, Lanxiao; Chen, Shan; Zhu, Xiaoyang; Han, Ce; Zheng, Xiaomin; Deng, Zhenxiang; Zhou, Yongqiang; Gong, Changfei; Xie, Congying; Jin, Xiance

    2018-03-01

    A multidimensional exploratory statistical method, canonical correlation analysis (CCA), was applied to evaluate the impact of complexity parameters on the plan quality and deliverability of volumetric-modulated arc therapy (VMAT) and to determine parameters in the generation of an ideal VMAT plan. Canonical correlations among complexity, quality and deliverability parameters of VMAT, as well as the contribution weights of different parameters were investigated with 71 two-arc VMAT nasopharyngeal cancer (NPC) patients, and further verified with 28 one-arc VMAT prostate cancer patients. The average MU and MU per control point (MU/CP) for two-arc VMAT plans were 702.6 ± 55.7 and 3.9 ± 0.3 versus 504.6 ± 99.2 and 5.6 ± 1.1 for one-arc VMAT plans, respectively. The individual volume-based 3D gamma passing rates of clinical target volume (γCTV) and planning target volume (γPTV) for NPC and prostate cancer patients were 85.7% ± 9.0% vs 92.6% ± 7.8%, and 88.0% ± 7.6% vs 91.2% ± 7.7%, respectively. Plan complexity parameters of NPC patients were correlated with plan quality (P = 0.047) and individual volume-based 3D gamma indices γ(IV) (P = 0.01), in which, MU/CP and segment area (SA) per control point (SA/CP) were weighted highly in correlation with γ(IV) , and SA/CP, percentage of CPs with SA < 5 × 5 cm2 (%SA < 5 × 5 cm2) and PTV volume were weighted highly in correlation with plan quality with coefficients of 0.98, 0.68 and -0.99, respectively. Further verification with one-arc VMAT plans demonstrated similar results. In conclusion, MU, SA-related parameters and PTV volume were found to have strong effects on the plan quality and deliverability.

  12. Multidimensional correlation among plan complexity, quality and deliverability parameters for volumetric-modulated arc therapy using canonical correlation analysis

    PubMed Central

    Shen, Lanxiao; Chen, Shan; Zhu, Xiaoyang; Han, Ce; Zheng, Xiaomin; Deng, Zhenxiang; Zhou, Yongqiang; Gong, Changfei; Jin, Xiance

    2018-01-01

    Abstract A multidimensional exploratory statistical method, canonical correlation analysis (CCA), was applied to evaluate the impact of complexity parameters on the plan quality and deliverability of volumetric-modulated arc therapy (VMAT) and to determine parameters in the generation of an ideal VMAT plan. Canonical correlations among complexity, quality and deliverability parameters of VMAT, as well as the contribution weights of different parameters were investigated with 71 two-arc VMAT nasopharyngeal cancer (NPC) patients, and further verified with 28 one-arc VMAT prostate cancer patients. The average MU and MU per control point (MU/CP) for two-arc VMAT plans were 702.6 ± 55.7 and 3.9 ± 0.3 versus 504.6 ± 99.2 and 5.6 ± 1.1 for one-arc VMAT plans, respectively. The individual volume-based 3D gamma passing rates of clinical target volume (γCTV) and planning target volume (γPTV) for NPC and prostate cancer patients were 85.7% ± 9.0% vs 92.6% ± 7.8%, and 88.0% ± 7.6% vs 91.2% ± 7.7%, respectively. Plan complexity parameters of NPC patients were correlated with plan quality (P = 0.047) and individual volume-based 3D gamma indices γ(IV) (P = 0.01), in which, MU/CP and segment area (SA) per control point (SA/CP) were weighted highly in correlation with γ(IV) , and SA/CP, percentage of CPs with SA < 5 × 5 cm2 (%SA < 5 × 5 cm2) and PTV volume were weighted highly in correlation with plan quality with coefficients of 0.98, 0.68 and −0.99, respectively. Further verification with one-arc VMAT plans demonstrated similar results. In conclusion, MU, SA-related parameters and PTV volume were found to have strong effects on the plan quality and deliverability. PMID:29415196

  13. Instrumentation for air quality measurements.

    NASA Technical Reports Server (NTRS)

    Loewenstein, M.

    1973-01-01

    Comparison of the new generation of air quality monitoring instruments with some more traditional methods. The first generation of air quality measurement instruments, based on the use of oxidant coulometric cells, nitrogen oxide colorimetry, carbon monoxide infrared analyzers, and other types of detectors, is compared with new techniques now coming into wide use in the air monitoring field and involving the use of chemiluminescent reactions, optical absorption detectors, a refinement of the carbon monoxide infrared analyzer, electrochemical cells based on solid electrolytes, and laser detectors.

  14. Competency-Based Education: A Framework for Measuring Quality Courses

    ERIC Educational Resources Information Center

    Krause, Jackie; Dias, Laura Portolese; Schedler, Chris

    2015-01-01

    The growth of competency-based education in an online environment requires the development and measurement of quality competency-based courses. While quality measures for online courses have been developed and standardized, they do not directly align with emerging best practices and principles in the design of quality competency-based online…

  15. Predictive capacity of sperm quality parameters and sperm subpopulations on field fertility after artificial insemination in sheep.

    PubMed

    Santolaria, P; Vicente-Fiel, S; Palacín, I; Fantova, E; Blasco, M E; Silvestre, M A; Yániz, J L

    2015-12-01

    This study was designed to evaluate the relevance of several sperm quality parameters and sperm population structure on the reproductive performance after cervical artificial insemination (AI) in sheep. One hundred and thirty-nine ejaculates from 56 adult rams were collected using an artificial vagina, processed for sperm quality assessment and used to perform 1319 AI. Analyses of sperm motility by computer-assisted sperm analysis (CASA), sperm nuclear morphometry by computer-assisted sperm morphometry analysis (CASMA), membrane integrity by acridine orange-propidium iodide combination and sperm DNA fragmentation using the sperm chromatin dispersion test (SCD) were performed. Clustering procedures using the sperm kinematic and morphometric data resulted in the classification of spermatozoa into three kinematic and three morphometric sperm subpopulations. Logistic regression procedures were used, including fertility at AI as the dependent variable (measured by lambing, 0 or 1) and farm, year, month of AI, female parity, female lambing-treatment interval, ram, AI technician and sperm quality parameters (including sperm subpopulations) as independent factors. Sperm quality variables remaining in the logistic regression model were viability and VCL. Fertility increased for each one-unit increase in viability (by a factor of 1.01) and in VCL (by a factor of 1.02). Multiple linear regression analyses were also performed to analyze the factors possibly influencing ejaculate fertility (N=139). The analysis yielded a significant (P<0.05) relationship between sperm viability and ejaculate fertility. The discriminant ability of the different semen variables to predict field fertility was analyzed using receiver operating characteristic (ROC) curve analysis. Sperm viability and VCL showed significant, albeit limited, predictive capacity on field fertility (0.57 and 0.54 Area Under Curve, respectively). The distribution of spermatozoa in the different subpopulations was not

  16. Improvement in Quality of Life Questionnaire Measures (PCOSQ) in Obese Adolescent Females with PCOS treated with Lifestyle Changes and Oral Contraceptives, with or without Metformin

    PubMed Central

    Harris-Glocker, Miranda; Davidson, Kristin; Kochman, Lynda; Guzick, David; Hoeger, Kathleen

    2013-01-01

    We studied the effect of metformin or placebo in a lifestyle modification program (LSM) combined with oral contraceptives (OC) on quality of life parameters measured by the PCOS questionnaire (PCOSQ) in obese adolescent women with validated PCOS. The quality of life indicators were measured at baseline and conclusion for 5 domains on the PCOSQ, with equal improvement in scores in both placebo and Metformin groups, suggesting metformin addition does not add improvement to quality of life measures above those observed with lifestyle modification and oral contraceptive treatment. PMID:19781696

  17. Quality of Life. Volume I: Conceptualization and Measurement.

    ERIC Educational Resources Information Center

    Schalock, Robert L., Ed.; Siperstein, Gary N., Ed.

    This volume deals with the conceptualization and measurement of quality of life for persons with mental retardation and developmental disabilities. Part 1, "The Conceptualization of Quality of Life," contains: "Self Advocacy: Foundation for Quality of Life" (Nancy A. Ward and Kenneth D. Keith); "Quality of Life and the Individual's Perspective"…

  18. Image quality assessment for CT used on small animals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cisneros, Isabela Paredes, E-mail: iparedesc@unal.edu.co; Agulles-Pedrós, Luis, E-mail: lagullesp@unal.edu.co

    Image acquisition on a CT scanner is nowadays necessary in almost any kind of medical study. Its purpose, to produce anatomical images with the best achievable quality, implies the highest diagnostic radiation exposure to patients. Image quality can be measured quantitatively based on parameters such as noise, uniformity and resolution. This measure allows the determination of optimal parameters of operation for the scanner in order to get the best diagnostic image. A human Phillips CT scanner is the first one minded for veterinary-use exclusively in Colombia. The aim of this study was to measure the CT image quality parameters usingmore » an acrylic phantom and then, using the computational tool MATLAB, determine these parameters as a function of current value and window of visualization, in order to reduce dose delivery by keeping the appropriate image quality.« less

  19. Image quality assessment for CT used on small animals

    NASA Astrophysics Data System (ADS)

    Cisneros, Isabela Paredes; Agulles-Pedrós, Luis

    2016-07-01

    Image acquisition on a CT scanner is nowadays necessary in almost any kind of medical study. Its purpose, to produce anatomical images with the best achievable quality, implies the highest diagnostic radiation exposure to patients. Image quality can be measured quantitatively based on parameters such as noise, uniformity and resolution. This measure allows the determination of optimal parameters of operation for the scanner in order to get the best diagnostic image. A human Phillips CT scanner is the first one minded for veterinary-use exclusively in Colombia. The aim of this study was to measure the CT image quality parameters using an acrylic phantom and then, using the computational tool MatLab, determine these parameters as a function of current value and window of visualization, in order to reduce dose delivery by keeping the appropriate image quality.

  20. Characterization of chromophoric dissolved organic matter and relationships among PARAFAC components and water quality parameters in Heilongjiang, China.

    PubMed

    Cui, Hongyang; Shi, Jianhong; Qiu, Linlin; Zhao, Yue; Wei, Zimin; Wang, Xinglei; Jia, Liming; Li, Jiming

    2016-05-01

    Chromophoric dissolved organic matter (CDOM) is an important optically active substance that can transports nutrients and pollutants from terrestrial to aquatic systems. Additionally, it is used as a measure of water quality. To investigate the source and composition of CDOM, we used chemical and fluorescent analyses to characterize CDOM in Heilongjiang. The composition of CDOM can be investigated by excitation-emission matrix (EEM) fluorescence and parallel factor analysis (PARAFAC). PARAFAC identified four individual components that were attributed to microbial humic-like (C1) and terrestrial humic-like (C2-4) in water samples collected from the Heilongjiang River. The relationships between the maximum fluorescence intensities of the four PARAFAC components and the water quality parameters indicate that the dynamic of the four components is related to nutrients in the Heilongjiang River. The relationships between the fluorescence component C3 and the biochemical oxygen demand (BOD5) indicates that component C3 makes a great contribution to BOD5 and it can be used as a carbon source for microbes in the Heilongjiang River. Furthermore, the relationships between component C3, the particulate organic carbon (POC), and the chemical oxygen demand (CODMn) show that component C3 and POC make great contributions to BOD5 and CODMn. The use of these indexes along with PARAFAC results would be of help to characterize the co-variation between the CDOM and water quality parameters in the Heilongjiang River.

  1. Geostatistical Characteristic of Space -Time Variation in Underground Water Selected Quality Parameters in Klodzko Water Intake Area (SW Part of Poland)

    NASA Astrophysics Data System (ADS)

    Namysłowska-Wilczyńska, Barbara

    2016-04-01

    This paper presents selected results of research connected with the development of a (3D) geostatistical hydrogeochemical model of the Klodzko Drainage Basin, dedicated to the spatial and time variation in the selected quality parameters of underground water in the Klodzko water intake area (SW part of Poland). The research covers the period 2011÷2012. Spatial analyses of the variation in various quality parameters, i.e, contents of: ammonium ion [gNH4+/m3], NO3- (nitrate ion) [gNO3/m3], PO4-3 (phosphate ion) [gPO4-3/m3], total organic carbon C (TOC) [gC/m3], pH redox potential and temperature C [degrees], were carried out on the basis of the chemical determinations of the quality parameters of underground water samples taken from the wells in the water intake area. Spatial and time variation in the quality parameters was analyzed on the basis of archival data (period 1977÷1999) for 22 (pump and siphon) wells with a depth ranging from 9.5 to 38.0 m b.g.l., later data obtained (November 2011) from tests of water taken from 14 existing wells. The wells were built in the years 1954÷1998. The water abstraction depth (difference between the terrain elevation and the dynamic water table level) is ranged from 276÷286 m a.s.l., with an average of 282.05 m a.s.l. Dynamic water table level is contained between 6.22 m÷16.44 m b.g.l., with a mean value of 9.64 m b.g.l. The latest data (January 2012) acquired from 3 new piezometers, with a depth of 9÷10m, which were made in other locations in the relevant area. Thematic databases, containing original data on coordinates X, Y (latitude, longitude) and Z (terrain elevation and time - years) and on regionalized variables, i.e. the underground water quality parameters in the Klodzko water intake area determined for different analytical configurations (22 wells, 14 wells, 14 wells + 3 piezometers), were created. Both archival data (acquired in the years 1977÷1999) and the latest data (collected in 2011÷2012) were analyzed

  2. Field Measurement of the Acoustic Nonlinearity Parameter in Turbine Blades

    NASA Technical Reports Server (NTRS)

    Hinton, Yolanda L.; Na, Jeong K.; Yost, William T.; Kessel, Gregory L.

    2000-01-01

    Nonlinear acoustics techniques were used to measure fatigue in turbine blades in a power generation plant. The measurements were made in the field using a reference based measurement technique, and a reference sample previously measured in the laboratory. The acoustic nonlinearity parameter showed significant increase with fatigue in the blades, as indicated by service age and areas of increased stress. The technique shows promise for effectively measuring fatigue in field applications and predicting subsequent failures.

  3. Investigations of a flat-panel detector for quality assurance measurements in ion beam therapy.

    PubMed

    Hartmann, Bernadette; Telsemeyer, Julia; Huber, Lucas; Ackermann, Benjamin; Jäkel, Oliver; Martišíková, Mária

    2012-01-07

    Increased accuracy in radiation delivery to a patient provided by scanning particle beams leads to high demands on quality assurance (QA). To meet the requirements, an extensive quality assurance programme has been implemented at the Heidelberg Ion Beam Therapy Center. Currently, high-resolution radiographic films are used for beam spot position measurements and homogeneity measurements for scanned fields. However, given that using this film type is time and equipment demanding, considerations have been made to replace the radiographic films in QA by another appropriate device. In this study, the suitability of the flat-panel detector RID 256 L based on amorphous silicon was investigated as an alternative method. The currently used radiographic films were taken as a reference. Investigations were carried out for proton and carbon ion beams. The detectors were irradiated simultaneously to allow for a direct comparison. The beam parameters (e.g. energy, focus, position) currently used in the daily QA procedures were applied. Evaluation of the measurements was performed using newly implemented automatic routines. The results for the flat-panel detector were compared to the standard radiographic films. Additionally, a field with intentionally decreased homogeneity was applied to test the detector's sensitivities toward possible incorrect scan parameters. For the beam position analyses, the flat-panel detector results showed good agreement with radiographic films. For both detector types, deviations between measured and planned spot distances were found to be below 1% (1 mm). In homogeneously irradiated fields, the flat-panel detector showed a better dose response homogeneity than the currently used radiographic film. Furthermore, the flat-panel detector is sensitive to field irregularities. The flat-panel detector was found to be an adequate replacement for the radiographic film in QA measurements. In addition, it saves time and equipment because no post

  4. Instructional Alignment as a Measure of Teaching Quality

    ERIC Educational Resources Information Center

    Polikoff, Morgan S.; Porter, Andrew C.

    2014-01-01

    Recent years have seen the convergence of two major policy streams in U.S. K-12 education: standards/accountability and teacher quality reforms. Work in these areas has led to the creation of multiple measures of teacher quality, including measures of their instructional alignment to standards/assessments, observational and student survey measures…

  5. Integration of optical measurement methods with flight parameter measurement systems

    NASA Astrophysics Data System (ADS)

    Kopecki, Grzegorz; Rzucidlo, Pawel

    2016-05-01

    During the AIM (advanced in-flight measurement techniques) and AIM2 projects, innovative modern techniques were developed. The purpose of the AIM project was to develop optical measurement techniques dedicated for flight tests. Such methods give information about aircraft elements deformation, thermal loads or pressure distribution, etc. In AIM2 the development of optical methods for flight testing was continued. In particular, this project aimed at the development of methods that could be easily applied in flight tests in an industrial setting. Another equally important task was to guarantee the synchronization of the classical measuring system with cameras. The PW-6U glider used in flight tests was provided by the Rzeszów University of Technology. The glider had all the equipment necessary for testing the IPCT (image pattern correlation technique) and IRT (infrared thermometry) methods. Additionally, equipment adequate for the measurement of typical flight parameters, registration and analysis has been developed. This article describes the designed system, as well as presenting the system’s application during flight tests. Additionally, the results obtained in flight tests show certain limitations of the IRT method as applied.

  6. Rapid and Simultaneous Prediction of Eight Diesel Quality Parameters through ATR-FTIR Analysis.

    PubMed

    Nespeca, Maurilio Gustavo; Hatanaka, Rafael Rodrigues; Flumignan, Danilo Luiz; de Oliveira, José Eduardo

    2018-01-01

    Quality assessment of diesel fuel is highly necessary for society, but the costs and time spent are very high while using standard methods. Therefore, this study aimed to develop an analytical method capable of simultaneously determining eight diesel quality parameters (density; flash point; total sulfur content; distillation temperatures at 10% (T10), 50% (T50), and 85% (T85) recovery; cetane index; and biodiesel content) through attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy and the multivariate regression method, partial least square (PLS). For this purpose, the quality parameters of 409 samples were determined using standard methods, and their spectra were acquired in ranges of 4000-650 cm -1 . The use of the multivariate filters, generalized least squares weighting (GLSW) and orthogonal signal correction (OSC), was evaluated to improve the signal-to-noise ratio of the models. Likewise, four variable selection approaches were tested: manual exclusion, forward interval PLS (FiPLS), backward interval PLS (BiPLS), and genetic algorithm (GA). The multivariate filters and variables selection algorithms generated more fitted and accurate PLS models. According to the validation, the FTIR/PLS models presented accuracy comparable to the reference methods and, therefore, the proposed method can be applied in the diesel routine monitoring to significantly reduce costs and analysis time.

  7. Rapid and Simultaneous Prediction of Eight Diesel Quality Parameters through ATR-FTIR Analysis

    PubMed Central

    Hatanaka, Rafael Rodrigues; Flumignan, Danilo Luiz; de Oliveira, José Eduardo

    2018-01-01

    Quality assessment of diesel fuel is highly necessary for society, but the costs and time spent are very high while using standard methods. Therefore, this study aimed to develop an analytical method capable of simultaneously determining eight diesel quality parameters (density; flash point; total sulfur content; distillation temperatures at 10% (T10), 50% (T50), and 85% (T85) recovery; cetane index; and biodiesel content) through attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy and the multivariate regression method, partial least square (PLS). For this purpose, the quality parameters of 409 samples were determined using standard methods, and their spectra were acquired in ranges of 4000–650 cm−1. The use of the multivariate filters, generalized least squares weighting (GLSW) and orthogonal signal correction (OSC), was evaluated to improve the signal-to-noise ratio of the models. Likewise, four variable selection approaches were tested: manual exclusion, forward interval PLS (FiPLS), backward interval PLS (BiPLS), and genetic algorithm (GA). The multivariate filters and variables selection algorithms generated more fitted and accurate PLS models. According to the validation, the FTIR/PLS models presented accuracy comparable to the reference methods and, therefore, the proposed method can be applied in the diesel routine monitoring to significantly reduce costs and analysis time. PMID:29629209

  8. Use of ocean color scanner data in water quality mapping

    NASA Technical Reports Server (NTRS)

    Khorram, S.

    1981-01-01

    Remotely sensed data, in combination with in situ data, are used in assessing water quality parameters within the San Francisco Bay-Delta. The parameters include suspended solids, chlorophyll, and turbidity. Regression models are developed between each of the water quality parameter measurements and the Ocean Color Scanner (OCS) data. The models are then extended to the entire study area for mapping water quality parameters. The results include a series of color-coded maps, each pertaining to one of the water quality parameters, and the statistical analysis of the OCS data and regression models. It is found that concurrently collected OCS data and surface truth measurements are highly useful in mapping the selected water quality parameters and locating areas having relatively high biological activity. In addition, it is found to be virtually impossible, at least within this test site, to locate such areas on U-2 color and color-infrared photography.

  9. Data-quality measures for stakeholder-implemented watershed-monitoring programs

    USGS Publications Warehouse

    Greve, Adrienne I.

    2002-01-01

    Community-based watershed groups, many of which collect environmental data, have steadily increased in number over the last decade. The data generated by these programs are often underutilized due to uncertainty in the quality of data produced. The incorporation of data-quality measures into stakeholder monitoring programs lends statistical validity to data. Data-quality measures are divided into three steps: quality assurance, quality control, and quality assessment. The quality-assurance step attempts to control sources of error that cannot be directly quantified. This step is part of the design phase of a monitoring program and includes clearly defined, quantifiable objectives, sampling sites that meet the objectives, standardized protocols for sample collection, and standardized laboratory methods. Quality control (QC) is the collection of samples to assess the magnitude of error in a data set due to sampling, processing, transport, and analysis. In order to design a QC sampling program, a series of issues needs to be considered: (1) potential sources of error, (2) the type of QC samples, (3) inference space, (4) the number of QC samples, and (5) the distribution of the QC samples. Quality assessment is the process of evaluating quality-assurance measures and analyzing the QC data in order to interpret the environmental data. Quality assessment has two parts: one that is conducted on an ongoing basis as the monitoring program is running, and one that is conducted during the analysis of environmental data. The discussion of the data-quality measures is followed by an example of their application to a monitoring program in the Big Thompson River watershed of northern Colorado.

  10. A Structured-Grid Quality Measure for Simulated Hypersonic Flows

    NASA Technical Reports Server (NTRS)

    Alter, Stephen J.

    2004-01-01

    A structured-grid quality measure is proposed, combining three traditional measurements: intersection angles, stretching, and curvature. Quality assesses whether the grid generated provides the best possible tradeoffs in grid stretching and skewness that enable accurate flow predictions, whereas the grid density is assumed to be a constraint imposed by the available computational resources and the desired resolution of the flow field. The usefulness of this quality measure is assessed by comparing heat transfer predictions from grid convergence studies for grids of varying quality in the range of [0.6-0.8] on an 8'half-angle sphere-cone, at laminar, perfect gas, Mach 10 wind tunnel conditions.

  11. Measuring Service Quality in a Tertiary Institution.

    ERIC Educational Resources Information Center

    Soutar, Geoffrey; McNeil, Margaret

    1996-01-01

    Measures service quality from the viewpoint of customers (students at an Australian university), using the SERVQUAL model. Obtains evaluations of academic and administrative aspects of the educational service. Makes significant negative evaluations of administrative service quality (resulting from communication problems). Satisfaction with the…

  12. Systematic evidence-based quality measurement life-cycle approach to measure retirement in CHIPRA.

    PubMed

    Dougherty, Denise; Mistry, Kamila B; Lindly, Olivia; Desoto, Maushami; LLanos, Karen; Chesley, Francis

    2014-01-01

    In 2009, Centers for Medicare and Medicaid Services (CMS) publicly released an initial child core set (CCS) of health care quality measures for voluntary reporting by state Medicaid and Children's Health Insurance Program (CHIP) programs. CMS is responsible for implementing the reporting program and for updating the CCS annually. We assessed selected CCS measures for potential retirement. We identified a 23-member external advisory group to provide relevant expertise. We worked with the group to identify 4 major criteria with multiple subcomponents for assessing the measures. We provided information corresponding to each criterion and subcriterion, using a variety of sources such as the 2009 Medicaid Analytic eXtract (MAX), state-level Medicaid and CHIP data submitted to the CMS, and summaries of published literature on clinical and quality improvement effectiveness related to the CCS topics. Using this information, the group: 1) used a modified Delphi process to score the measures in 2 anonymous scoring rounds (on a scale of 1 to 9 in each round); 2) voted on whether each measure should be retired; and 3) provided narrative explanations of their choices (which formed the basis of our qualitative findings). Recommendations were reviewed by CMS before promulgation to state programs. The Subcommittee of the National Advisory Council on Healthcare Research and Quality (SNAC) recommended that the 4 major criteria be importance, scientific acceptability, feasibility, and usability. The SNAC recommended 3 measures for retirement: access to primary care; testing for strep before recommending antibiotics for pharyngitis; and annual HbA1c testing of children with diabetes. Explanations for suggesting retirement of the measures included: views that the well-visit measures were a better measure of access than the primary care measure; a likely ceiling effect (pharyngitis); and the paucity of clinical evidence and low prevalence (both for HbA1c). CMS recommended that state

  13. Effects of the bilateral isokinetic strengthening training on functional parameters, gait, and the quality of life in patients with stroke.

    PubMed

    Büyükvural Şen, Sıdıka; Özbudak Demir, Sibel; Ekiz, Timur; Özgirgin, Neşe

    2015-01-01

    To evaluate the effects of the bilateral isokinetic strengthening training applied to knee and ankle muscles on balance, functional parameters, gait, and the quality of in stroke patients. Fifty patients (33 M, 17 F) with subacute-chronic stroke and 30 healthy subjects were included. Stroke patients were allocated into isokinetic and control groups. Conventional rehabilitation program was applied to all cases; additionally maximal concentric isokinetic strengthening training was applied to the knee-ankle muscles bilaterally to the isokinetic group 5 days a week for 3 weeks. Biodex System 3 Pro Multijoint System isokinetic dynamometer was used for isokinetic evaluation. The groups were assessed by Functional Independence Measure, Stroke Specific Quality of Life Scale, Timed 10-Meter Walk Test, Six-Minute Walk Test, Stair-Climbing Test, Timed up&go Test, Berg Balance Scale, and Rivermead Mobility Index. Compared with baseline, the isokinetic PT values of the knee and ankle on both sides significantly increased in all cases. PT change values were significantly higher in the isokinetic group than the control group (P<0.025). Furthermore, the quality of life, gait, balance and mobility index values improved significantly in both groups, besides the increase levels were found significantly higher in the isokinetic group (P<0.025, P<0.05). Bilateral isokinetic strengthening training in addition to conventional rehabilitation program after stroke seems to be effective on strengthening muscles on both sides, improving functional parameters, gait, balance and life quality.

  14. Effects of the bilateral isokinetic strengthening training on functional parameters, gait, and the quality of life in patients with stroke

    PubMed Central

    Büyükvural Şen, Sıdıka; Özbudak Demir, Sibel; Ekiz, Timur; Özgirgin, Neşe

    2015-01-01

    Objective: To evaluate the effects of the bilateral isokinetic strengthening training applied to knee and ankle muscles on balance, functional parameters, gait, and the quality of in stroke patients. Methods: Fifty patients (33 M, 17 F) with subacute-chronic stroke and 30 healthy subjects were included. Stroke patients were allocated into isokinetic and control groups. Conventional rehabilitation program was applied to all cases; additionally maximal concentric isokinetic strengthening training was applied to the knee-ankle muscles bilaterally to the isokinetic group 5 days a week for 3 weeks. Biodex System 3 Pro Multijoint System isokinetic dynamometer was used for isokinetic evaluation. The groups were assessed by Functional Independence Measure, Stroke Specific Quality of Life Scale, Timed 10-Meter Walk Test, Six-Minute Walk Test, Stair-Climbing Test, Timed up&go Test, Berg Balance Scale, and Rivermead Mobility Index. Results: Compared with baseline, the isokinetic PT values of the knee and ankle on both sides significantly increased in all cases. PT change values were significantly higher in the isokinetic group than the control group (P<0.025). Furthermore, the quality of life, gait, balance and mobility index values improved significantly in both groups, besides the increase levels were found significantly higher in the isokinetic group (P<0.025, P<0.05). Conclusion: Bilateral isokinetic strengthening training in addition to conventional rehabilitation program after stroke seems to be effective on strengthening muscles on both sides, improving functional parameters, gait, balance and life quality. PMID:26629238

  15. The combined effect of wet granulation process parameters and dried granule moisture content on tablet quality attributes.

    PubMed

    Gabbott, Ian P; Al Husban, Farhan; Reynolds, Gavin K

    2016-09-01

    A pharmaceutical compound was used to study the effect of batch wet granulation process parameters in combination with the residual moisture content remaining after drying on granule and tablet quality attributes. The effect of three batch wet granulation process parameters was evaluated using a multivariate experimental design, with a novel constrained design space. Batches were characterised for moisture content, granule density, crushing strength, porosity, disintegration time and dissolution. Mechanisms of the effect of the process parameters on the granule and tablet quality attributes are proposed. Water quantity added during granulation showed a significant effect on granule density and tablet dissolution rate. Mixing time showed a significant effect on tablet crushing strength, and mixing speed showed a significant effect on the distribution of tablet crushing strengths obtained. The residual moisture content remaining after granule drying showed a significant effect on tablet crushing strength. The effect of moisture on tablet tensile strength has been reported before, but not in combination with granulation parameters and granule properties, and the impact on tablet dissolution was not assessed. Correlations between the energy input during granulation, the density of granules produced, and the quality attributes of the final tablets were also identified. Understanding the impact of the granulation and drying process parameters on granule and tablet properties provides a basis for process optimisation and scaling. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Measurement of Device Parameters Using Image Recovery Techniques in Large-Scale IC Devices

    NASA Technical Reports Server (NTRS)

    Scheick, Leif; Edmonds, Larry

    2004-01-01

    Devices that respond to radiation on a cell level will produce histograms showing the relative frequency of cell damage as a function of damage. The measured distribution is the convolution of distributions from radiation responses, measurement noise, and manufacturing parameters. A method of extracting device characteristics and parameters from measured distributions via mathematical and image subtraction techniques is described.

  17. Variation of Water Quality Parameters with Siltation Depth for River Ichamati Along International Border with Bangladesh Using Multivariate Statistical Techniques

    NASA Astrophysics Data System (ADS)

    Roy, P. K.; Pal, S.; Banerjee, G.; Biswas Roy, M.; Ray, D.; Majumder, A.

    2014-12-01

    River is considered as one of the main sources of freshwater all over the world. Hence analysis and maintenance of this water resource is globally considered a matter of major concern. This paper deals with the assessment of surface water quality of the Ichamati river using multivariate statistical techniques. Eight distinct surface water quality observation stations were located and samples were collected. For the samples collected statistical techniques were applied to the physico-chemical parameters and depth of siltation. In this paper cluster analysis is done to determine the relations between surface water quality and siltation depth of river Ichamati. Multiple regressions and mathematical equation modeling have been done to characterize surface water quality of Ichamati river on the basis of physico-chemical parameters. It was found that surface water quality of the downstream river was different from the water quality of the upstream. The analysis of the water quality parameters of the Ichamati river clearly indicate high pollution load on the river water which can be accounted to agricultural discharge, tidal effect and soil erosion. The results further reveal that with the increase in depth of siltation, water quality degraded.

  18. 40 CFR 80.46 - Measurement of reformulated gasoline fuel parameters.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 16 2011-07-01 2011-07-01 false Measurement of reformulated gasoline... (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Reformulated Gasoline § 80.46 Measurement of reformulated gasoline fuel parameters. (a) Sulfur. Sulfur content of gasoline and butane must...

  19. 40 CFR 80.46 - Measurement of reformulated gasoline fuel parameters.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 17 2012-07-01 2012-07-01 false Measurement of reformulated gasoline... (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Reformulated Gasoline § 80.46 Measurement of reformulated gasoline fuel parameters. (a) Sulfur. Sulfur content of gasoline and butane must...

  20. 40 CFR 80.46 - Measurement of reformulated gasoline fuel parameters.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 17 2013-07-01 2013-07-01 false Measurement of reformulated gasoline... (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Reformulated Gasoline § 80.46 Measurement of reformulated gasoline fuel parameters. (a) Sulfur. Sulfur content of gasoline and butane must...

  1. The impact of the Internet on quality measurement.

    PubMed

    Bates, D W; Gawande, A A

    2000-01-01

    Consumers are eager for information about health. However, their use of such data has been limited to date. When consumers do consider data in making health care choices, they rely more on word-of-mouth reputation than on traditional quality measures, although this information has not necessarily been readily accessible. The Internet changes the exercise of quality measurement in several ways. First, quality information--including reputation--will be more readily available. Second, consumers will increasingly use it. Third, the Internet provides a low-cost, standard platform that will make it vastly easier for providers to collect quality information and pass it on to others. However, major barriers still stand in the way of public access to quality information on the Internet as well as of having that access actually improve patients' care.

  2. Bioactive compounds and quality parameters of natural cloudy lemon juices.

    PubMed

    Uçan, Filiz; Ağçam, Erdal; Akyildiz, Asiye

    2016-03-01

    In this study, bioactive compounds (phenolic and carotenoid) and some quality parameters (color, browning index and hydroxymethylfurfural (HMF)) of natural cloudy lemon juice, pasteurized (90 °C/15 s) and storage stability of concentrated lemon juice (-25 °C/180 days) were carried out. Fifteen phenolic compounds were determined in the lemon juice and the most abounded phenolic compounds were hesperidin, eriocitrin, chlorogenic acid and neoeriocitrin. In generally, phenolic compound concentrations of lemon juice samples increased after the pasteurization treatment. Four carotenoid compounds (β-carotene, β-cryptoxanthin, lutein and zeaxanthin) were detected in natural cloudy lemon juice. Lutein and β-cryptoxanthin were the most abounded carotenoid compounds in the lemon juice. Color values of the lemon juices were not affected by processing and storage periods. HMF and browning index of the lemon juices increased with concentration and storage. According to the results, storing at -25 °C was considered as sufficient for acceptable quality limits of natural cloudy lemon juice.

  3. Effects of steam inhalation on voice quality-related acoustic measures.

    PubMed

    Mahalingam, Shenbagavalli; Boominathan, Prakash

    2016-10-01

    To investigate the effects of steam inhalation using a facial steamer on voice quality-related acoustic measures. Prospective outcome research: single-blinded experimental study. Forty-five vocally healthy female subjects ranging in age from 18 to 30 years (Mean age: 22.41 years; standard deviation [SD]: 8.91) participated in the study. Phonation samples were recorded under three different conditions in triplicate: baseline recording, immediately after mouth breathing (dehydration), and immediately after 3 minutes of steam inhalation via the mouth (rehydration). In the initial voice recording (prior to dehydration), mean jitter (0.42 %; SD: 0.07), shimmer (2.20 dB; SD: 0.45), and harmonics-to-noise ratio (HNR) (21.60; SD: 2.41) values were within normal limits. After short-term mouth breathing (dehydration, approximately 10 minutes), the mean jitter (1.57 %; SD: 1.82) and shimmer (4.73 dB; SD: 1.83) were significantly increased (P < 0.05), and HNR (18.64; SD: 3.16) was reduced (P < 0.05). After steam inhalation (rehydration) for 3 minutes, mean jitter (0.48 %; SD: 0.12) and shimmer (2.70 dB; SD: 0.71) showed significant decrease (P < 0.05), and HNR (20.10; SD: 3.69) showed significant increase (P < 0.05). All parameters statistically significantly improved from post dehydration values. The simple procedure of steam inhalation using a facial steamer displayed positive effects on parameters proposed to reflect voice quality. 4. Laryngoscope, 126:2305-2309, 2016. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  4. Measuring Quality in Online Education: A Meta-Synthesis

    ERIC Educational Resources Information Center

    Esfijani, Azam

    2018-01-01

    This article presents a meta-synthesis review of quality of online education (QOE) measurement approaches. In order to survey the existing body of knowledge, a qualitative method was employed to investigate what quality of online education is comprised of and how the concept has been measured through the literature. To achieve this, a total of 112…

  5. The Attributive Theory of Quality: A Model for Quality Measurement in Higher Education.

    ERIC Educational Resources Information Center

    Afshar, Arash

    A theoretical basis for defining and measuring the quality of institutions of higher education, namely for accreditation purposes, is developed. The theory, the Attributive Theory of Quality, is illustrated using a calculation model that is based on general systems theory. The theory postulates that quality only exists in relation to the…

  6. Nuclear size as estrogen-responsive chromatin quality parameter of mouse spermatozoa.

    PubMed

    Cacciola, Giovanna; Chioccarelli, Teresa; Altucci, Lucia; Viggiano, Andrea; Fasano, Silvia; Pierantoni, Riccardo; Cobellis, Gilda

    2013-11-01

    Recently, we have investigated the endocannabinoid involvement in chromatin remodeling events occurring in male spermatids. Indeed, we have demonstrated that genetic inactivation of the cannabinoid receptor type 1 (Cnr1) negatively influences chromatin remodeling mechanisms, by reducing histone displacement and indices of sperm chromatin quality (chromatin condensation and DNA integrity). Conversely, Cnr1 knock-out (Cnr1(-/-)) male mice, treated with estrogens, replaced histones and rescued chromatin condensation as well as DNA integrity. In the present study, by exploiting Cnr1(+/+), Cnr(+/-) and Cnr1(-/-) epididymal sperm samples, we show that histone retention directly correlates with low values of sperm chromatin quality indices determining sperm nuclear size elongation. Moreover, we demonstrate that estrogens, by promoting histone displacement and chromatin condensation rescue, are able to efficiently reduce the greater nuclear length observed in Cnr1(-/-) sperm. As a consequence of our results, we suggest that nucleus length may be used as a morphological parameter useful to screen out spermatozoa with low chromatin quality. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. Theory and practice for measuring health care quality

    PubMed Central

    Berwick, Donald M.; Knapp, Marian Gilbert

    1987-01-01

    As competition, cost control, and new modes of delivery emerge in health care, there is a need to reexamine both the traditional definitions of health care quality and the methods by which it is measured. Industries other than health care have much to teach regarding the methods for obtaining, analyzing, and displaying data; techniques for problem identification, problem solving, and reassessment; and ideas about organizational factors that produce a high quality product or service. The Quality-of-Care Measurement Department at the Harvard Community Health Plan has built a program that draws from a distinguished health care quality assurance tradition and incorporates techniques that have been successful in other industries. PMID:10312319

  8. Optimal design of monitoring networks for multiple groundwater quality parameters using a Kalman filter: application to the Irapuato-Valle aquifer.

    PubMed

    Júnez-Ferreira, H E; Herrera, G S; González-Hita, L; Cardona, A; Mora-Rodríguez, J

    2016-01-01

    A new method for the optimal design of groundwater quality monitoring networks is introduced in this paper. Various indicator parameters were considered simultaneously and tested for the Irapuato-Valle aquifer in Mexico. The steps followed in the design were (1) establishment of the monitoring network objectives, (2) definition of a groundwater quality conceptual model for the study area, (3) selection of the parameters to be sampled, and (4) selection of a monitoring network by choosing the well positions that minimize the estimate error variance of the selected indicator parameters. Equal weight for each parameter was given to most of the aquifer positions and a higher weight to priority zones. The objective for the monitoring network in the specific application was to obtain a general reconnaissance of the water quality, including water types, water origin, and first indications of contamination. Water quality indicator parameters were chosen in accordance with this objective, and for the selection of the optimal monitoring sites, it was sought to obtain a low-uncertainty estimate of these parameters for the entire aquifer and with more certainty in priority zones. The optimal monitoring network was selected using a combination of geostatistical methods, a Kalman filter and a heuristic optimization method. Results show that when monitoring the 69 locations with higher priority order (the optimal monitoring network), the joint average standard error in the study area for all the groundwater quality parameters was approximately 90 % of the obtained with the 140 available sampling locations (the set of pilot wells). This demonstrates that an optimal design can help to reduce monitoring costs, by avoiding redundancy in data acquisition.

  9. Air Quality Measurements for Science and Policy

    EPA Science Inventory

    Air quality measurements and the methods used to conduct them are vital to advancing our knowledge of the source-to-receptor-to-health effects continuum1-3. This information then forms the basis for evaluating and managing air quality to protect human health and welfa...

  10. Measuring Indoor Air Quality of Hookah Lounges

    PubMed Central

    Fiala, Steven C.; Pawlak, Rebecca L.

    2012-01-01

    Many states have implemented smoke-free workplace laws to protect employees and customers from exposure to secondhand smoke. However, exemptions in these laws have allowed indoor tobacco smoking in hookah lounges to proliferate in recent years. To describe the amount of secondhand smoke in hookah lounges, we measured the indoor air quality of 10 hookah lounges in Oregon. Air quality measurements ranged from “unhealthy” to “hazardous” according to Environmental Protection Agency standards, indicating a potential health risk for patrons and employees. PMID:22994168

  11. Toward an applied technology for quality measurement in health care.

    PubMed

    Berwick, D M

    1988-01-01

    Cost containment, financial incentives to conserve resources, the growth of for-profit hospitals, an aggressive malpractice environment, and demands from purchasers are among the forces today increasing the need for improved methods that measure quality in health care. At the same time, increasingly sophisticated databases and the existence of managed care systems yield new opportunities to observe and correct quality problems. Research on targets of measurement (structure, process, and outcome) and methods of measurement (implicit, explicit, and sentinel methods) has not yet produced managerially useful applied technology for quality measurement in real-world settings. Such an applied technology would have to be cheaper, faster, more flexible, better reported, and more multidimensional than the majority of current research on quality assurance. In developing a new applied technology for the measurement of health care quality, quantitative disciplines have much to offer, such as decision support systems, criteria based on rigorous decision analyses, utility theory, tools for functional status measurement, and advances in operations research.

  12. Impact of Quality Improvement Educational Interventions on Documented Adherence to Quality Measures for Adults with Crohn's Disease.

    PubMed

    Greene, Laurence; Sapir, Tamar; Moreo, Kathleen; Carter, Jeffrey D; Patel, Barry; Higgins, Peter D R

    2015-09-01

    In recent years, leading organizations in inflammatory bowel disease (IBD) have developed quality measures for the care of adults with Crohn's disease or ulcerative colitis. We used chart audits to assess the impact of quality improvement educational activities on documented adherence to Physician Quality Reporting System measures for IBD. Twenty community-based gastroenterologists were recruited to participate in baseline chart audits (n = 200), a series of 4 accredited educational activities with feedback, and follow-up chart audits (n = 200). Trained abstractors reviewed randomly selected charts of adults with moderate or severe Crohn's disease. The charts were retrospectively abstracted for physicians' documented performance of the 2013 Physician Quality Reporting System IBD quality measures. We compared the physicians' baseline and posteducation rates of documented adherence with 10 of these measures. In a secondary analysis, we compared preeducation with posteducation difference scores of low-performing physicians, those whose baseline documentation rates were in the lowest quartile, and the rest of the cohort. At baseline, documentation of mean provider-level adherence to the 10 quality measures ranged from 3% to 98% (grand mean = 35.8%). In the overall analysis, baseline and posteducation rates of documented adherence did not differ significantly for any of the measures. However, for 4 measures, preeducation to posteducation difference scores were significantly greater among low performers than physicians in the highest 3 quartiles. The results of this preliminary pragmatic study indicate that quality improvement education affords the potential to improve adherence to Physician Quality Reporting System quality measures for IBD among low-performing gastroenterologists.

  13. Sperm quality biomarkers complement reproductive and endocrine parameters in investigating environmental contaminants in common carp (Cyprinus carpio) from the Lake Mead National Recreation Area

    USGS Publications Warehouse

    Jenkins, Jill A.; Rosen, Michael R.; Dale, Rassa O.; Echols, Kathy R.; Torres, Leticia; Wieser, Carla M.; Kersten, Constance A.; Goodbred, Steven L.

    2018-01-01

    Lake Mead National Recreational Area (LMNRA) serves as critical habitat for several federally listed species and supplies water for municipal, domestic, and agricultural use in the Southwestern U.S. Contaminant sources and concentrations vary among the sub-basins within LMNRA. To investigate whether exposure to environmental contaminants is associated with alterations in male common carp (Cyprinus carpio) gamete quality and endocrine- and reproductive parameters, data were collected among sub-basins over 7 years (1999–2006). Endpoints included sperm quality parameters of motility, viability, mitochondrial membrane potential, count, morphology, and DNA fragmentation; plasma components were vitellogenin (VTG), 17ß-estradiol, 11-keto-testosterone, triiodothyronine, and thyroxine. Fish condition factor, gonadosomatic index, and gonadal histology parameters were also measured. Diminished biomarker effects were noted in 2006, and sub-basin differences were indicated by the irregular occurrences of contaminants and by several associations between chemicals (e.g., polychlorinated biphenyls, hexachlorobenzene, galaxolide, and methyl triclosan) and biomarkers (e.g., plasma thyroxine, sperm motility and DNA fragmentation). By 2006, sex steroid hormone and VTG levels decreased with subsequent reduced endocrine disrupting effects. The sperm quality bioassays developed and applied with carp complemented endocrine and reproductive data, and can be adapted for use with other species.

  14. Sperm quality biomarkers complement reproductive and endocrine parameters in investigating environmental contaminants in common carp (Cyprinus carpio) from the Lake Mead National Recreation Area.

    PubMed

    Jenkins, Jill A; Rosen, Michael R; Draugelis-Dale, Rassa O; Echols, Kathy R; Torres, Leticia; Wieser, Carla M; Kersten, Constance A; Goodbred, Steven L

    2018-05-01

    Lake Mead National Recreational Area (LMNRA) serves as critical habitat for several federally listed species and supplies water for municipal, domestic, and agricultural use in the Southwestern U.S. Contaminant sources and concentrations vary among the sub-basins within LMNRA. To investigate whether exposure to environmental contaminants is associated with alterations in male common carp (Cyprinus carpio) gamete quality and endocrine- and reproductive parameters, data were collected among sub-basins over 7 years (1999-2006). Endpoints included sperm quality parameters of motility, viability, mitochondrial membrane potential, count, morphology, and DNA fragmentation; plasma components were vitellogenin (VTG), 17ß-estradiol, 11-keto-testosterone, triiodothyronine, and thyroxine. Fish condition factor, gonadosomatic index, and gonadal histology parameters were also measured. Diminished biomarker effects were noted in 2006, and sub-basin differences were indicated by the irregular occurrences of contaminants and by several associations between chemicals (e.g., polychlorinated biphenyls, hexachlorobenzene, galaxolide, and methyl triclosan) and biomarkers (e.g., plasma thyroxine, sperm motility and DNA fragmentation). By 2006, sex steroid hormone and VTG levels decreased with subsequent reduced endocrine disrupting effects. The sperm quality bioassays developed and applied with carp complemented endocrine and reproductive data, and can be adapted for use with other species. Published by Elsevier Inc.

  15. Preliminary assessment of several parameters to measure and compare usefulness of the CEOS reference pseudo-invariant calibration sites

    USGS Publications Warehouse

    Chander, Gyanesh; Angal, Amit; Xiong, Xiaoxiong; Helder, Dennis L.; Mishra, Nischal; Choi, Taeyoung; Wu, Aisheng

    2010-01-01

    Test sites are central to any future quality assurance and quality control (QA/QC) strategy. The Committee on Earth Observation Satellites (CEOS) Working Group for Calibration and Validation (WGCV) Infrared Visible Optical Sensors (IVOS) worked with collaborators around the world to establish a core set of CEOS-endorsed, globally distributed, reference standard test sites (both instrumented and pseudo-invariant) for the post-launch calibration of space-based optical imaging sensors. The pseudo-invariant calibration sites (PICS) have high reflectance and are usually made up of sand dunes with low aerosol loading and practically no vegetation. The goal of this paper is to provide preliminary assessment of "several parameters" than can be used on an operational basis to compare and measure usefulness of reference sites all over the world. The data from Landsat 7 (L7) Enhanced Thematic Mapper Plus (ETM+) and the Earth Observing-1 (EO-1) Hyperion sensors over the CEOS PICS were used to perform a preliminary assessment of several parameters, such as usable area, data availability, top-of-atmosphere (TOA) reflectance, at-sensor brightness temperature, spatial uniformity, temporal stability, spectral stability, and typical spectrum observed over the sites.

  16. Influence of anthropometric parameters on ultrasound measurements of Os calcis.

    PubMed

    Hans, D; Schott, A M; Arlot, M E; Sornay, E; Delmas, P D; Meunier, P J

    1995-01-01

    Few data have been published concerning the influence of height, weight and body mass index (BMI) on broadband ultrasound attenuation (BUA), speed of sound (SOS) and Lunar "stiffness" index, and always in small population samples. The first ain of the present cross-sectional study was to determine whether anthropometric factors have a significant influence on ultrasound measurements. The second objective was to establish whether these parameters have real effect on whether their influence is due only to measurement errors. We measured, in 271 healthy French women (mean age 77 +/- 11 years; range 31-97 years), the following parameters: age, height, weight, lean and fat body mass, heel width, foot length, knee height and external malleolus (HEM). Simple linear regression analyses between ultrasound and anthropometric parameters were performed. Age, height, and heel width were significant predictors of SOS; age, height, weight, foot length, heel width, HEM, fat mass and lean mass were significant predictors of BUA; age, height, weight, heel width, HEM, fat mass and lean mass were significant predictors of stiffness. In the multiple regression analysis, once the analysis had been adjusted for age, only heel width was a significant predictor for SOS (p = 0.0007), weight for BUA (p = 0.0001), and weight (p = 0.0001) and heel width (p = 0.004) for the stiffness index. Besides their statistical meaning, the regression coefficients have a more clinically relevant interpretation which is developed in the text. These results confirm the influence of anthropometric factors on the ultrasonic parameter values, because BUA and SOS were in part dependent on heel width and weight. The influence of the position of the transducer on the calcaneus should be taken into account to optimize the methods of measurement using ultrasound.

  17. Wearable sensors objectively measure gait parameters in Parkinson’s disease

    PubMed Central

    Marxreiter, Franz; Gossler, Julia; Kohl, Zacharias; Reinfelder, Samuel; Gassner, Heiko; Aminian, Kamiar; Eskofier, Bjoern M.; Winkler, Jürgen; Klucken, Jochen

    2017-01-01

    Distinct gait characteristics like short steps and shuffling gait are prototypical signs commonly observed in Parkinson’s disease. Routinely assessed by observation through clinicians, gait is rated as part of categorical clinical scores. There is an increasing need to provide quantitative measurements of gait, e.g. to provide detailed information about disease progression. Recently, we developed a wearable sensor-based gait analysis system as diagnostic tool that objectively assesses gait parameter in Parkinson’s disease without the need of having a specialized gait laboratory. This system consists of inertial sensor units attached laterally to both shoes. The computed target of measures are spatiotemporal gait parameters including stride length and time, stance phase time, heel-strike and toe-off angle, toe clearance, and inter-stride variation from gait sequences. To translate this prototype into medical care, we conducted a cross-sectional study including 190 Parkinson’s disease patients and 101 age-matched controls and measured gait characteristics during a 4x10 meter walk at the subjects’ preferred speed. To determine intraindividual changes in gait, we monitored the gait characteristics of 63 patients longitudinally. Cross-sectional analysis revealed distinct spatiotemporal gait parameter differences reflecting typical Parkinson’s disease gait characteristics including short steps, shuffling gait, and postural instability specific for different disease stages and levels of motor impairment. The longitudinal analysis revealed that gait parameters were sensitive to changes by mirroring the progressive nature of Parkinson’s disease and corresponded to physician ratings. Taken together, we successfully show that wearable sensor-based gait analysis reaches clinical applicability providing a high biomechanical resolution for gait impairment in Parkinson’s disease. These data demonstrate the feasibility and applicability of objective wearable sensor

  18. Implications of measures of quality of life for policy development.

    PubMed

    Mosteller, F

    1987-01-01

    Quality of life measurements can lead to legislative programs for health, new policies for the health care system, and possibly new attitudes in the courts. Clinical decisions, public health evaluations, and advice for legislatures and courts require diverse measures. We illustrate potential use of such measures with reimbursement problems, programs like Head Start, mainstreaming the handicapped, day care and prenatal care, terminal care for the elderly, monitoring programs, and chronic disabilities. The many treatment policies discussed at the Portugal Conference show the need for quality of life measures in clinical trials. The courts, although considering quality of life, do not seem to consider quality of life measures. If scientists and medical experts wish to establish or change the positions of the courts, consensus conferences appear more effective than regulation or new legislation. To contribute more than they now do to policy, workers measuring quality of life need to develop a variety of measures and methods. They, then, must apply them to medical and health problems, build up a substantial literature, and set priorities for the research needs of the field.

  19. Adaptive measurements of urban runoff quality

    NASA Astrophysics Data System (ADS)

    Wong, Brandon P.; Kerkez, Branko

    2016-11-01

    An approach to adaptively measure runoff water quality dynamics is introduced, focusing specifically on characterizing the timing and magnitude of urban pollutographs. Rather than relying on a static schedule or flow-weighted sampling, which can miss important water quality dynamics if parameterized inadequately, novel Internet-enabled sensor nodes are used to autonomously adapt their measurement frequency to real-time weather forecasts and hydrologic conditions. This dynamic approach has the potential to significantly improve the use of constrained experimental resources, such as automated grab samplers, which continue to provide a strong alternative to sampling water quality dynamics when in situ sensors are not available. Compared to conventional flow-weighted or time-weighted sampling schemes, which rely on preset thresholds, a major benefit of the approach is the ability to dynamically adapt to features of an underlying hydrologic signal. A 28 km2 urban watershed was studied to characterize concentrations of total suspended solids (TSS) and total phosphorus. Water quality samples were autonomously triggered in response to features in the underlying hydrograph and real-time weather forecasts. The study watershed did not exhibit a strong first flush and intraevent concentration variability was driven by flow acceleration, wherein the largest loadings of TSS and total phosphorus corresponded with the steepest rising limbs of the storm hydrograph. The scalability of the proposed method is discussed in the context of larger sensor network deployments, as well the potential to improving control of urban water quality.

  20. Measurements of the dissolved inorganic carbon system and associated biogeochemical parameters in the Canadian Arctic, 1974-2009

    NASA Astrophysics Data System (ADS)

    Giesbrecht, K. E.; Miller, L. A.; Davelaar, M.; Zimmermann, S.; Carmack, E.; Johnson, W. K.; Macdonald, R. W.; McLaughlin, F.; Mucci, A.; Williams, W. J.; Wong, C. S.; Yamamoto-Kawai, M.

    2014-03-01

    We have assembled and conducted primary quality control on previously publicly unavailable water column measurements of the dissolved inorganic carbon system and associated biogeochemical parameters (oxygen, nutrients, etc.) made on 26 cruises in the subarctic and Arctic regions dating back to 1974. The measurements are primarily from the western side of the Canadian Arctic, but also include data that cover an area ranging from the North Pacific to the Gulf of St. Lawrence. The data were subjected to primary quality control (QC) to identify outliers and obvious errors. This data set incorporates over four thousand individual measurements of total inorganic carbon (TIC), alkalinity, and pH from the Canadian Arctic over a period of more than 30 years and provides an opportunity to increase our understanding of temporal changes in the inorganic carbon system in northern waters and the Arctic Ocean. The data set is available for download on the CDIAC (Carbon Dioxide Information Analysis Center) website: http://cdiac.ornl.gov/ftp/oceans/IOS_Arctic_Database/ (doi:10.3334/CDIAC/OTG.IOS_ARCT_CARBN).

  1. Composite Quality Measures for Common Inpatient Medical Conditions

    PubMed Central

    Chen, Lena M.; Staiger, Douglas O.; Birkmeyer, John D.; Ryan, Andrew M.; Zhang, Wenying; Dimick, Justin B.

    2014-01-01

    Background Public reporting on quality aims to help patients select better hospitals. However, individual quality measures are sub-optimal in identifying superior and inferior hospitals based on outcome performance. Objective To combine structure, process, and outcome measures into an empirically-derived composite quality measure for heart failure (HF), acute myocardial infarction (AMI), and pneumonia (PNA). To assess how well the composite measure predicts future high and low performers, and explains variance in future hospital mortality. Research Design Using national Medicare data, we created a cohort of older patients treated at an acute care hospital for HF (n=1,203,595), AMI (n=625,595), or PNA (n=1,234,299). We ranked hospitals based on their July 2005 to June 2008 performance on the composite. We then estimated the odds of future (July to December 2009) 30-day, risk-adjusted mortality at the worst vs. best quintile of hospitals. We repeated this analysis using 2005-2008 performance on existing quality indicators, including mortality. Results The composite (vs. Hospital Compare) explained 68% (vs. 39%) of variation in future AMI mortality rates. In 2009, if an AMI patient had chosen a hospital in the worst vs. best quintile of performance using 2005-2008 composite (vs. Hospital Compare) rankings, he or she would have had 1.61 (vs. 1.39) times the odds of dying in 30 days (p-value for difference < 0.001). Results were similar for HF and PNA. Conclusions Composite measures of quality for HF, AMI, and PNA performed better than existing measures at explaining variation in future mortality and predicting future high and low performers. PMID:23942222

  2. A Foot-Arch Parameter Measurement System Using a RGB-D Camera.

    PubMed

    Chun, Sungkuk; Kong, Sejin; Mun, Kyung-Ryoul; Kim, Jinwook

    2017-08-04

    The conventional method of measuring foot-arch parameters is highly dependent on the measurer's skill level, so accurate measurements are difficult to obtain. To solve this problem, we propose an autonomous geometric foot-arch analysis platform that is capable of capturing the sole of the foot and yields three foot-arch parameters: arch index (AI), arch width (AW) and arch height (AH). The proposed system captures 3D geometric and color data on the plantar surface of the foot in a static standing pose using a commercial RGB-D camera. It detects the region of the foot surface in contact with the footplate by applying the clustering and Markov random field (MRF)-based image segmentation methods. The system computes the foot-arch parameters by analyzing the 2/3D shape of the contact region. Validation experiments were carried out to assess the accuracy and repeatability of the system. The average errors for AI, AW, and AH estimation on 99 data collected from 11 subjects during 3 days were -0.17%, 0.95 mm, and 0.52 mm, respectively. Reliability and statistical analysis on the estimated foot-arch parameters, the robustness to the change of weights used in the MRF, the processing time were also performed to show the feasibility of the system.

  3. Measurement of the Michel rho parameter in direct muon decay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Piilonen, Leo; Haim, D.; Lee, F. S.

    1997-05-20

    We report on the status of LAMPF experiment E-1240 to measure the Michel {rho} parameter in direct muon decay. This experiment ran in 1993, and the data are currently being analyzed. The expected precision on the {rho} parameter is {+-}0.0008. This result will provide better constraints on new physics, particularly on the charged vector bosons' mixing angle {zeta} in the manifestly left-right symmetric extension of the Standard Model.

  4. Evaluation of Shiraz wastewater treatment plant effluent quality for agricultural irrigation by Canadian Water Quality Index (CWQI)

    PubMed Central

    2013-01-01

    Background Using treated wastewater in agriculture irrigation could be a realistic solution for the shortage of fresh water in Iran, however, it is associated with environmental and health threats; therefore, effluent quality assessment is quite necessary before use. The present study aimed to evaluate the physicochemical and microbial quality of Shiraz wastewater treatment plant effluent for being used in agricultural irrigation. In this study, 20 physicochemical and 3 microbial parameters were measured during warm (April to September) and cold months (October to march). Using the measured parameters and the Canadian Water Quality Index, the quality of the effluent was determined in both warm and cold seasons and in all the seasons together. Results The calculated index for the physicochemical parameters in the effluent was equal (87) in warm and cold months and it was obtained as 85 for the seasons all together. When the microbial parameters were used in order to calculate the index, it declined to 67 in warm and cold seasons and 64 in all the seasons together. Also, it was found that three physicochemical parameters (TDS, EC, and NO3) and three microbial parameters (Fecal coliform, Helminthes egg, and Total coliform) had the most contribution to the reduction of the index value. Conclusions The results showed that the physicochemical quality of Shiraz Wastewater Treatment Plant Effluent was good for irrigation in the warm, cold, and total of the two kinds of seasons. However, by applying the microbial parameter, the index value declined dramatically and the quality of the effluent was marginal. PMID:23566673

  5. Rural southeast Texas air quality measurements during the 2006 Texas Air Quality Study.

    PubMed

    Schade, Gunnar W; Khan, Siraj; Park, Changhyoun; Boedeker, Ian

    2011-10-01

    The authors conducted air quality measurements of the criteria pollutants carbon monoxide, nitrogen oxides, and ozone together with meteorological measurements at a park site southeast of College Station, TX, during the 2006 Texas Air Quality Study II (TexAQS). Ozone, a primary focus of the measurements, was above 80 ppb during 3 days and above 75 ppb during additional 8 days in summer 2006, suggestive of possible violations of the ozone National Ambient Air Quality Standard (NAAQS) in this area. In concordance with other air quality measurements during the TexAQS II, elevated ozone mixing ratios coincided with northerly flows during days after cold front passages. Ozone background during these days was as high as 80 ppb, whereas southerly air flows generally provided for an ozone background lower than 40 ppb. Back trajectory analysis shows that local ozone mixing ratios can also be strongly affected by the Houston urban pollution plume, leading to late afternoon ozone increases of as high as 50 ppb above background under favorable transport conditions. The trajectory analysis also shows that ozone background increases steadily the longer a southern air mass resides over Texas after entering from the Gulf of Mexico. In light of these and other TexAQS findings, it appears that ozone air quality is affected throughout east Texas by both long-range and regional ozone transport, and that improvements therefore will require at least a regionally oriented instead of the current locally oriented ozone precursor reduction policies.

  6. Determination of Complex Microcalorimeter Parameters with Impedance Measurements

    NASA Technical Reports Server (NTRS)

    Saab, T.; Bandler, S. R.; Chervenak, J.; Figueroa-Feliciano, E.; Finkbeiner, F.; Iyomoto, N.; Kelley, R.; Kilbourne, C. A.; Lindeman, M. A.; Porter, F. S.; hide

    2005-01-01

    The proper understanding and modeling of a microcalorimeter s response requires the accurate knowledge of a handful of parameters, such as C, G, alpha, . . . . While a few of these, such 8s the normal state resistance and the total thermal conductance to the heat bath (G) are directly determined from the DC IV characteristics, some others, notoriously the heat capacity (C) and alpha, appear in degenerate combinations in most measurable quantities. The case of a complex microcalorimeter, i.e. one in which the absorber s heat capacity is connected by a finite thermal impedance to the sensor, and subsequently by another thermal impedance to the heat bath, results in an added ambiguity in the determination of the individual C's and G's. In general, the dependence of the microcalorimeter s complex impedance on these parameters varies with frequency. This variation allows us to determine the individual parameters by fitting the prediction of the microcalorimeter model to the impedance data. We describe in this paper our efforts at characterizing the Goddard X-ray microcalorimeters. Using the parameters determined with this method we them compare the pulse shape and noise spectra predicted by the microcalorimeter model to data taken with the same devices.

  7. The association between quality of care and quality of life in long-stay nursing home residents with preserved cognition.

    PubMed

    Kim, Sun Jung; Park, Eun-Cheol; Kim, Sulgi; Nakagawa, Shunichi; Lung, John; Choi, Jong Bum; Ryu, Woo Sang; Min, Too Jae; Shin, Hyun Phil; Kim, Kyudam; Yoo, Ji Won

    2014-03-01

    To assess the overall quality of life of long-stay nursing home residents with preserved cognition, to examine whether the Centers for Medicare and Medicaid Service's Nursing Home Compare 5-star quality rating system reflects the overall quality of life of such residents, and to examine whether residents' demographics and clinical characteristics affect their quality of life. Quality of life was measured using the Participant Outcomes and Status Measures-Nursing Facility survey, which has 10 sections and 63 items. Total scores range from 20 (lowest possible quality of life) to 100 (highest). Long-stay nursing home residents with preserved cognition (n = 316) were interviewed. The average quality- of-life score was 71.4 (SD: 7.6; range: 45.1-93.0). Multilevel regression models revealed that quality of life was associated with physical impairment (parameter estimate = -0.728; P = .04) and depression (parameter estimate = -3.015; P = .01) but not Nursing Home Compare's overall star rating (parameter estimate = 0.683; P = .12) and not pain (parameter estimate = -0.705; P = .47). The 5-star quality rating system did not reflect the quality of life of long-stay nursing home residents with preserved cognition. Notably, pain was not associated with quality of life, but physical impairment and depression were. Copyright © 2014 American Medical Directors Association, Inc. Published by Elsevier Inc. All rights reserved.

  8. Prediction of pork quality parameters by applying fractals and data mining on MRI.

    PubMed

    Caballero, Daniel; Pérez-Palacios, Trinidad; Caro, Andrés; Amigo, José Manuel; Dahl, Anders B; ErsbØll, Bjarne K; Antequera, Teresa

    2017-09-01

    This work firstly investigates the use of MRI, fractal algorithms and data mining techniques to determine pork quality parameters non-destructively. The main objective was to evaluate the capability of fractal algorithms (Classical Fractal algorithm, CFA; Fractal Texture Algorithm, FTA and One Point Fractal Texture Algorithm, OPFTA) to analyse MRI in order to predict quality parameters of loin. In addition, the effect of the sequence acquisition of MRI (Gradient echo, GE; Spin echo, SE and Turbo 3D, T3D) and the predictive technique of data mining (Isotonic regression, IR and Multiple linear regression, MLR) were analysed. Both fractal algorithm, FTA and OPFTA are appropriate to analyse MRI of loins. The sequence acquisition, the fractal algorithm and the data mining technique seems to influence on the prediction results. For most physico-chemical parameters, prediction equations with moderate to excellent correlation coefficients were achieved by using the following combinations of acquisition sequences of MRI, fractal algorithms and data mining techniques: SE-FTA-MLR, SE-OPFTA-IR, GE-OPFTA-MLR, SE-OPFTA-MLR, with the last one offering the best prediction results. Thus, SE-OPFTA-MLR could be proposed as an alternative technique to determine physico-chemical traits of fresh and dry-cured loins in a non-destructive way with high accuracy. Copyright © 2017. Published by Elsevier Ltd.

  9. Measuring the quality of health care: state of the art.

    PubMed

    Donaldson, M S; Nolan, K

    1997-05-01

    September 12-13, 1996, in Washington, DC, the Institute of Medicine, as part of its Special Initiative on Health Care Quality, held an invitational conference to illustrate exemplary quality measurement and to discuss the results. Patient reports, innovative uses of outcome measures for quality improvement, risk adjustment, assessment in integrated health plans and health care settings, clinical guidelines, and projects on disseminating information on quality measurement techniques and tools were among the topics represented. Brent James described studies undertaken to reduce adverse drug events (ADEs). When implementing any measurement system where error is a possible factor, it is important to emphasize identifying problems for the purpose of learning, not judgment. Lucian Leape agreed that staff involved must feel that the purpose of the study is to examine system problems, not individuals' mistakes. David Classen described a nonproprietary computerized disease-management program designed to reduce ADEs in infectious diseases. "A QUALITY VISION": Robert Brook said that the relationship between cost or resources devoted to care and quality is not well understood and is certainly not simple. He also said that although investments in measurement strategies are needed to make them better, that doesn't mean we shouldn't attempt to use the measurements we have now. Mark Chassin said that the presentations at the conference provided evidence that should allow us to conclude beyond a reasonable doubt that quality can be measured-with a degree of scientific precision equal to that of most of the measures used to take care of patients every day.

  10. Measurement of the geometric parameters of power contact wire based on binocular stereovision

    NASA Astrophysics Data System (ADS)

    Pan, Xue-Tao; Zhang, Ya-feng; Meng, Fei

    2010-10-01

    In the electrified railway power supply system, electric locomotive obtains power from the catenary's wire through the pantograph. Under the action of the pantograph, combined with various factors such as vibration, touch current, relative sliding speed, load, etc, the contact wire will produce mechanical wear and electrical wear. Thus, in electrified railway construction and daily operations, the geometric parameters such as line height, pull value, the width of wear surface must be under real-timely and non-contact detection. On the one hand, the safe operation of electric railways will be guaranteed; on the other hand, the wire endurance will be extended, and operating costs reduced. Based on the characteristics of the worn wires' image signal, the binocular stereo vision technology was applied for measurement of contact wire geometry parameters, a mathematical model of measurement of geometric parameters was derived, and the boundaries of the wound wire abrasion-point value were extracted by means of sub-pixel edge detection method based on the LOG operator with the least-squares fitting, thus measurements of the wire geometry parameters were realized. Principles were demonstrated through simulation experiments, and the experimental results show that the detection methods presented in this paper for measuring the accuracy, efficiency and convenience, etc. are close to or superior to the traditional measurements, which has laid a good foundation for the measurement system of geometric parameters for the contact wire of the development of binocular vision.

  11. Poster - Thur Eve - 10: Long term stability of VMAT quality assurance parameters using an EPID.

    PubMed

    Pekar, J; Diamond, K R

    2012-07-01

    The rapidly growing use of volumetric modulated arc therapy (VMAT) treatments in radiation therapy calls for a quantitative, automated, and reliable quality assurance (QA) procedure that can be used routinely in the clinical setting. In this work, we present a series VMAT QA procedures used to assess dynamic multi-leaf collimator (MLC) positional accuracy, variable dose-rate accuracy, and MLC leaf speed accuracy. The QA procedures were performed using amorphous silicon electronic portal imaging devices (EPID) to determine the long term stability of the measured parameters on two Varian linear accelerators. The measurements were repeated weekly on both linear accelerators for a period of three months and the EPID images were analyzed using custom Matlab software. The results of the picket fence tests indicate that MLC leaf positions can be identified to within 0.11 mm and 0.15 mm for static gantry delivery and VMAT delivery respectively. In addition, the dose-rate, gantry speed and MLC leaf speed tests both show very good stability over the measurement period. The measurements thus far, suggest that a number of the dosimetry tests may be suitable for quarterly QA for Varian iX and Trilogy linacs. However, additional measurements are required to confirm the frequency with which each test is required for safe and reliable VMAT delivery at our centre. © 2012 American Association of Physicists in Medicine.

  12. Evaluation of the influence of acquisition parameters of microtomography in image quality applied by carbonate rocks

    NASA Astrophysics Data System (ADS)

    Santos, T. M. P.; Machado, A. S.; Araújo, O. M. O.; Ferreira, C. G.; Lopes, R. T.

    2018-03-01

    X-ray computed microtomography is a powerful nondestructive technique for 2D and 3D structure analysis. However, parameters used in acquisition promote directs influence in qualitative and quantitative results in characterization of samples, due image resolution. The aim of this study is value the influence of theses parameters in results through of tests changing these parameters in different situations and system characterization. Results demonstrate those pixel size and detector matrixes are the main parameters that influence in resolution and image quality. Microtomography was considered an excellent technique for characterization using the best image resolution possible.

  13. Socio-economic and lifestyle parameters associated with diet quality of children and adolescents using classification and regression tree analysis: the DIATROFI study.

    PubMed

    Yannakoulia, Mary; Lykou, Anastasia; Kastorini, Christina Maria; Saranti Papasaranti, Eirini; Petralias, Athanassios; Veloudaki, Afroditi; Linos, Athena

    2016-02-01

    To explore factors affecting children's and adolescents' diet quality, in the framework of a food aid and promotion of healthy nutrition programme implemented in areas of low socio-economic status of Greece, during the current financial crisis. From a total of 162 schools participating in the programme during 2012-2013, we gathered 15 897 questionnaires recording sociodemographic characteristics, lifestyle parameters and dietary habits of children and their families. As a measure of socio-economic status, the Family Affluence Scale (FAS) was used; whereas for the assessment of diet quality, the KIDMED score was computed. Associations between KIDMED and FAS, physical activity and socio-economic parameters were examined using regression and classification-regression tree analysis (CART). The higher the FAS score, the greater the percentage of children and adolescents who reported to consume, on a daily basis, fruits and vegetables, dairy products and breakfast (P<0·001). Results from CART showed that children and adolescents in the medium or high FAS groups had higher KIDMED score, compared with those in the low FAS group. For those in the low FAS group, KIDMED score is expected to increase by 12·4 % when they spend more than 0·25 h/week in sports activities. The respective threshold for the medium and high FAS groups is 1·75 h/week, while education of the mother and father affected KIDMED score significantly as well. Diet quality is strongly influenced by socio-economic parameters in children and adolescents living in economically disadvantaged areas of Greece, so that lower family affluence is associated with worse diet quality.

  14. Temporal variability in water quality parameters--a case study of drinking water reservoir in Florida, USA.

    PubMed

    Toor, Gurpal S; Han, Lu; Stanley, Craig D

    2013-05-01

    Our objective was to evaluate changes in water quality parameters during 1983-2007 in a subtropical drinking water reservoir (area: 7 km(2)) located in Lake Manatee Watershed (area: 338 km(2)) in Florida, USA. Most water quality parameters (color, turbidity, Secchi depth, pH, EC, dissolved oxygen, total alkalinity, cations, anions, and lead) were below the Florida potable water standards. Concentrations of copper exceeded the potable water standard of <30 μg l(-1) in about half of the samples. About 75 % of total N in lake was organic N (0.93 mg l(-1)) with the remainder (25 %) as inorganic N (NH3-N: 0.19, NO3-N: 0.17 mg l(-1)), while 86 % of total P was orthophosphate. Mean total N/P was <6:1 indicating N limitation in the lake. Mean monthly concentration of chlorophyll-a was much lower than the EPA water quality threshold of 20 μg l(-1). Concentrations of total N showed significant increase from 1983 to 1994 and a decrease from 1997 to 2007. Total P showed significant increase during 1983-2007. Mean concentrations of total N (n = 215; 1.24 mg l(-1)) were lower, and total P (n = 286; 0.26 mg l(-1)) was much higher than the EPA numeric criteria of 1.27 mg total N l(-1) and 0.05 mg total P l(-1) for Florida's colored lakes, respectively. Seasonal trends were observed for many water quality parameters where concentrations were typically elevated during wet months (June-September). Results suggest that reducing transport of organic N may be one potential option to protect water quality in this drinking water reservoir.

  15. A Linear Algebra Measure of Cluster Quality.

    ERIC Educational Resources Information Center

    Mather, Laura A.

    2000-01-01

    Discussion of models for information retrieval focuses on an application of linear algebra to text clustering, namely, a metric for measuring cluster quality based on the theory that cluster quality is proportional to the number of terms that are disjoint across the clusters. Explains term-document matrices and clustering algorithms. (Author/LRW)

  16. Measuring quality in services for children with an intellectual disability.

    PubMed

    Koornneef, Erik

    2006-01-01

    To evaluate the application of one particular quality measurement tool, the SERVQUAL instrument, as a potential mechanism to measure quality in services for children with disabilities Staff and family of children with an intellectual disability in two organisations providing specialist therapy and day completed an adapted SERVQUAL questionnaire. A total of 81 SERVQUAL questionnaires were distributed and 59 questionnaires were returned (response rate of 73 per cent). The SERVQUAL instrument can be considered as a useful diagnostic tool to identify particular strengths and areas for improvement in services for people with disabilities as the instrument lends itself for the monitoring of the effectiveness of quality improvement initiatives over time. The findings also showed relatively high customer expectations and the organisations involved in this research are currently not meeting all of these high expectations as significant quality gaps were found in the areas of reliability and responsiveness. The sample size was relatively small and the measurement of quality using the SERVQUAL instrument remains a challenge, due to the conceptual and empirical difficulties. The SERVQUAL instrument is probably most be attractive to service managers and funding organisations because of its ability to identify gaps in the quality of the service. The tool had been used to measure quality in services for people with disabilities and the research has shown that this tool might be an important additional quality measurement tool for services.

  17. THE MEASUREMENT OF BONE QUALITY USING GRAY LEVEL CO-OCCURRENCE MATRIX TEXTURAL FEATURES.

    PubMed

    Shirvaikar, Mukul; Huang, Ning; Dong, Xuanliang Neil

    2016-10-01

    In this paper, statistical methods for the estimation of bone quality to predict the risk of fracture are reported. Bone mineral density and bone architecture properties are the main contributors of bone quality. Dual-energy X-ray Absorptiometry (DXA) is the traditional clinical measurement technique for bone mineral density, but does not include architectural information to enhance the prediction of bone fragility. Other modalities are not practical due to cost and access considerations. This study investigates statistical parameters based on the Gray Level Co-occurrence Matrix (GLCM) extracted from two-dimensional projection images and explores links with architectural properties and bone mechanics. Data analysis was conducted on Micro-CT images of 13 trabecular bones (with an in-plane spatial resolution of about 50μm). Ground truth data for bone volume fraction (BV/TV), bone strength and modulus were available based on complex 3D analysis and mechanical tests. Correlation between the statistical parameters and biomechanical test results was studied using regression analysis. The results showed Cluster-Shade was strongly correlated with the microarchitecture of the trabecular bone and related to mechanical properties. Once the principle thesis of utilizing second-order statistics is established, it can be extended to other modalities, providing cost and convenience advantages for patients and doctors.

  18. THE MEASUREMENT OF BONE QUALITY USING GRAY LEVEL CO-OCCURRENCE MATRIX TEXTURAL FEATURES

    PubMed Central

    Shirvaikar, Mukul; Huang, Ning; Dong, Xuanliang Neil

    2016-01-01

    In this paper, statistical methods for the estimation of bone quality to predict the risk of fracture are reported. Bone mineral density and bone architecture properties are the main contributors of bone quality. Dual-energy X-ray Absorptiometry (DXA) is the traditional clinical measurement technique for bone mineral density, but does not include architectural information to enhance the prediction of bone fragility. Other modalities are not practical due to cost and access considerations. This study investigates statistical parameters based on the Gray Level Co-occurrence Matrix (GLCM) extracted from two-dimensional projection images and explores links with architectural properties and bone mechanics. Data analysis was conducted on Micro-CT images of 13 trabecular bones (with an in-plane spatial resolution of about 50μm). Ground truth data for bone volume fraction (BV/TV), bone strength and modulus were available based on complex 3D analysis and mechanical tests. Correlation between the statistical parameters and biomechanical test results was studied using regression analysis. The results showed Cluster-Shade was strongly correlated with the microarchitecture of the trabecular bone and related to mechanical properties. Once the principle thesis of utilizing second-order statistics is established, it can be extended to other modalities, providing cost and convenience advantages for patients and doctors. PMID:28042512

  19. Quantitative Determination of Spring Water Quality Parameters via Electronic Tongue.

    PubMed

    Carbó, Noèlia; López Carrero, Javier; Garcia-Castillo, F Javier; Tormos, Isabel; Olivas, Estela; Folch, Elisa; Alcañiz Fillol, Miguel; Soto, Juan; Martínez-Máñez, Ramón; Martínez-Bisbal, M Carmen

    2017-12-25

    The use of a voltammetric electronic tongue for the quantitative analysis of quality parameters in spring water is proposed here. The electronic voltammetric tongue consisted of a set of four noble electrodes (iridium, rhodium, platinum, and gold) housed inside a stainless steel cylinder. These noble metals have a high durability and are not demanding for maintenance, features required for the development of future automated equipment. A pulse voltammetry study was conducted in 83 spring water samples to determine concentrations of nitrate (range: 6.9-115 mg/L), sulfate (32-472 mg/L), fluoride (0.08-0.26 mg/L), chloride (17-190 mg/L), and sodium (11-94 mg/L) as well as pH (7.3-7.8). These parameters were also determined by routine analytical methods in spring water samples. A partial least squares (PLS) analysis was run to obtain a model to predict these parameter. Orthogonal signal correction (OSC) was applied in the preprocessing step. Calibration (67%) and validation (33%) sets were selected randomly. The electronic tongue showed good predictive power to determine the concentrations of nitrate, sulfate, chloride, and sodium as well as pH and displayed a lower R² and slope in the validation set for fluoride. Nitrate and fluoride concentrations were estimated with errors lower than 15%, whereas chloride, sulfate, and sodium concentrations as well as pH were estimated with errors below 10%.

  20. Dual redundant arm system operational quality measures and their applications - Static measures

    NASA Technical Reports Server (NTRS)

    Lee, Sukhan; Kim, Sungbok

    1990-01-01

    The authors present dual-arm system static operational quality measures which quantify the efficiency and capability of a dual-arm system in generating Cartesian velocities and static forces. First, they define and analyze the kinematic interactions between the two arms incurred by the various modes of dual-arm cooperation, such as transport, assembly, and grasping modes of cooperation, and specify the kinematic constraints imposed on individual arms in Cartesian space due to the kinematic interactions. Dual-arm static manipulability is presented. Finally, dual-arm operational quality is scaled by a task-oriented operational quality measure (TOQs) obtained by the comparison between the desired and actual static manipulabilities. TOQs is used in the optimization of dual-arm joint configurations. Simulation results are shown.

  1. Impact of image quality on OCT angiography based quantitative measurements.

    PubMed

    Al-Sheikh, Mayss; Ghasemi Falavarjani, Khalil; Akil, Handan; Sadda, SriniVas R

    2017-01-01

    To study the impact of image quality on quantitative measurements and the frequency of segmentation error with optical coherence tomography angiography (OCTA). Seventeen eyes of 10 healthy individuals were included in this study. OCTA was performed using a swept-source device (Triton, Topcon). Each subject underwent three scanning sessions 1-2 min apart; the first two scans were obtained under standard conditions and for the third session, the image quality index was reduced using application of a topical ointment. En face OCTA images of the retinal vasculature were generated using the default segmentation for the superficial and deep retinal layer (SRL, DRL). Intraclass correlation coefficient (ICC) was used as a measure for repeatability. The frequency of segmentation error, motion artifact, banding artifact and projection artifact was also compared among the three sessions. The frequency of segmentation error, and motion artifact was statistically similar between high and low image quality sessions (P = 0.707, and P = 1 respectively). However, the frequency of projection and banding artifact was higher with a lower image quality. The vessel density in the SRL was highly repeatable in the high image quality sessions (ICC = 0.8), however, the repeatability was low, comparing the high and low image quality measurements (ICC = 0.3). In the DRL, the repeatability of the vessel density measurements was fair in the high quality sessions (ICC = 0.6 and ICC = 0.5, with and without automatic artifact removal, respectively) and poor comparing high and low image quality sessions (ICC = 0.3 and ICC = 0.06, with and without automatic artifact removal, respectively). The frequency of artifacts is higher and the repeatability of the measurements is lower with lower image quality. The impact of image quality index should be always considered in OCTA based quantitative measurements.

  2. A research agenda to advance quality measurement and improvement.

    PubMed

    Leatherman, Sheila T; Hibbard, Judith H; McGlynn, Elizabeth A

    2003-01-01

    In developing a conceptual framework for the design of a national quality measurement and reporting system (NQMRS), the Strategic Framework Board (SFB) recommends that such a system be built on a strong evidence base. To identify critical gaps in the evidence needed for a fully functional NQMRS and to recommend a starting point for the development of a research agenda. Selective review of literature in quality of care measurement and reporting and identification of strategic issues that must be addressed. There is some limited evidence that measurement and reporting can improve quality. Substantial advances have been made in the science of measurement and reporting but important gaps remain, specifically in (1) measurement methods and tools, (2) uses of quality performance data, (3) organizational and cultural factors, (4) information and informatics, and (5) impact evaluation/research. To achieve a sustainable research agenda, three strategic issues will have to be addressed: (1) the policy rationale for the research agenda, (2) adequate levels of public-sector funding, and (3) sustainability in a rapidly changing environment.

  3. Partial compensation interferometry measurement system for parameter errors of conicoid surface

    NASA Astrophysics Data System (ADS)

    Hao, Qun; Li, Tengfei; Hu, Yao; Wang, Shaopu; Ning, Yan; Chen, Zhuo

    2018-06-01

    Surface parameters, such as vertex radius of curvature and conic constant, are used to describe the shape of an aspheric surface. Surface parameter errors (SPEs) are deviations affecting the optical characteristics of an aspheric surface. Precise measurement of SPEs is critical in the evaluation of optical surfaces. In this paper, a partial compensation interferometry measurement system for SPE of a conicoid surface is proposed based on the theory of slope asphericity and the best compensation distance. The system is developed to measure the SPE-caused best compensation distance change and SPE-caused surface shape change and then calculate the SPEs with the iteration algorithm for accuracy improvement. Experimental results indicate that the average relative measurement accuracy of the proposed system could be better than 0.02% for the vertex radius of curvature error and 2% for the conic constant error.

  4. Fabrication of a Miniature Multi-Parameter Sensor Chip for Water Quality Assessment.

    PubMed

    Zhou, Bo; Bian, Chao; Tong, Jianhua; Xia, Shanhong

    2017-01-14

    Water contamination is a main inducement of human diseases. It is an important step to monitor the water quality in the water distribution system. Due to the features of large size, high cost, and complicated structure of traditional water determination sensors and devices, it is difficult to realize real-time water monitoring on a large scale. In this paper, we present a multi-parameter sensor chip, which is miniature, low-cost, and robust, to detect the pH, conductivity, and temperature of water simultaneously. The sensor chip was fabricated using micro-electro-mechanical system (MEMS) techniques. Iridium oxide film was electrodeposited as the pH-sensing material. The atomic ratio of Ir(III) to Ir(IV) is about 1.38 according to the X-ray photoelectron spectroscopy (XPS) analysis. The pH sensing electrode showed super-Nernstian response (-67.60 mV/pH) and good linearity (R² = 0.9997), in the range of pH 2.22 to pH 11.81. KCl-agar and epoxy were used as the electrolyte layer and liquid junction for the solid-state reference electrode, respectively, and its potential stability in deionized water was 56 h. The conductivity cell exhibited a linear determination range from 21.43 μ S / cm to 1.99 mS / cm , and the electrode constant was 1.566 cm -1 . Sensitivity of the temperature sensor was 5.46 Ω / ° C . The results indicate that the developed sensor chip has potential application in water quality measurements.

  5. Fabrication of a Miniature Multi-Parameter Sensor Chip for Water Quality Assessment

    PubMed Central

    Zhou, Bo; Bian, Chao; Tong, Jianhua; Xia, Shanhong

    2017-01-01

    Water contamination is a main inducement of human diseases. It is an important step to monitor the water quality in the water distribution system. Due to the features of large size, high cost, and complicated structure of traditional water determination sensors and devices, it is difficult to realize real-time water monitoring on a large scale. In this paper, we present a multi-parameter sensor chip, which is miniature, low-cost, and robust, to detect the pH, conductivity, and temperature of water simultaneously. The sensor chip was fabricated using micro-electro-mechanical system (MEMS) techniques. Iridium oxide film was electrodeposited as the pH-sensing material. The atomic ratio of Ir(III) to Ir(IV) is about 1.38 according to the X-ray photoelectron spectroscopy (XPS) analysis. The pH sensing electrode showed super-Nernstian response (−67.60 mV/pH) and good linearity (R2 = 0.9997), in the range of pH 2.22 to pH 11.81. KCl-agar and epoxy were used as the electrolyte layer and liquid junction for the solid-state reference electrode, respectively, and its potential stability in deionized water was 56 h. The conductivity cell exhibited a linear determination range from 21.43 μS/cm to 1.99 mS/cm, and the electrode constant was 1.566 cm−1. Sensitivity of the temperature sensor was 5.46 Ω/°C. The results indicate that the developed sensor chip has potential application in water quality measurements. PMID:28098824

  6. Instrument for the measurement and determination of chemical pulse column parameters

    DOEpatents

    Marchant, Norman J.; Morgan, John P.

    1990-01-01

    An instrument for monitoring and measuring pneumatic driving force pulse parameters applied to chemical separation pulse columns obtains real time pulse frequency and root mean square amplitude values, calculates column inch values and compares these values against preset limits to alert column operators to the variations of pulse column operational parameters beyond desired limits.

  7. SU-E-I-59: Image Quality and Dose Measurement for Partial Cone-Beam CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abouei, E; Ford, N

    Purpose: To characterize performance of cone beam CT (CBCT) used in dentistry investigating quantitatively the image quality and radiation dose during dental CBCT over different settings for partial rotation of the x-ray tube. Methods: Image quality and dose measurements were done on a variable field of view (FOV) dental CBCT (Carestream 9300). X-ray parameters for clinical settings were adjustable for 2–10 mA, 60–90 kVp, and two optional voxel size values, but time was fixed for each FOV. Image quality was assessed by scanning cylindrical poly-methyl methacrylate (PMMA) image quality phantom (SEDENTEXCT IQ), and then the images were analyzed using ImageJmore » to calculate image quality parameters such as noise, uniformity, and contrast to noise ratio (CNR). A protocol proposed by SEDENTEXCT, dose index 1 (DI1), was applied to dose measurements obtained using a thimble ionization chamber and cylindrical PMMA dose index phantom (SEDENTEXCT DI). Dose distributions were obtained using Gafchromic film. The phantoms were positioned in the FOV to imitate a clinical positioning. Results: The image noise was 6–12.5% which, when normalized to the difference of mean voxel value of PMMA and air, was comparable between different FOVs. Uniformity was 93.5ß 99.7% across the images. CNR was 1.7–4.2 and 6.3–14.3 for LDPE and Aluminum, respectively. Dose distributions were symmetric about the rotation angle's bisector. For large and medium FOVs at 4 mA and 80–90 kVp, DI1 values were in the range of 1.26–3.23 mGy. DI1 values were between 1.01–1.93 mGy for small FOV (5×5 cm{sup 2}) at 4–5 mA and 75–84 kVp. Conclusion: Noise decreased by increasing kVp, and the CNR increased for each FOV. When FOV size increased, image noise increased and CNR decreased. DI1 values were increased by increasing tube current (mA), tube voltage (kVp), and/or FOV. Funding for this project from NSERC Discovery grant, UBC Faculty of Dentistry Research Equipment Grant and UBC Faculty

  8. The Aeroflex: A Bicycle for Mobile Air Quality Measurements

    PubMed Central

    Elen, Bart; Peters, Jan; Van Poppel, Martine; Bleux, Nico; Theunis, Jan; Reggente, Matteo; Standaert, Arnout

    2013-01-01

    Fixed air quality stations have limitations when used to assess people's real life exposure to air pollutants. Their spatial coverage is too limited to capture the spatial variability in, e.g., an urban or industrial environment. Complementary mobile air quality measurements can be used as an additional tool to fill this void. In this publication we present the Aeroflex, a bicycle for mobile air quality monitoring. The Aeroflex is equipped with compact air quality measurement devices to monitor ultrafine particle number counts, particulate mass and black carbon concentrations at a high resolution (up to 1 second). Each measurement is automatically linked to its geographical location and time of acquisition using GPS and Internet time. Furthermore, the Aeroflex is equipped with automated data transmission, data pre-processing and data visualization. The Aeroflex is designed with adaptability, reliability and user friendliness in mind. Over the past years, the Aeroflex has been successfully used for high resolution air quality mapping, exposure assessment and hot spot identification. PMID:23262484

  9. The Aeroflex: a bicycle for mobile air quality measurements.

    PubMed

    Elen, Bart; Peters, Jan; Poppel, Martine Van; Bleux, Nico; Theunis, Jan; Reggente, Matteo; Standaert, Arnout

    2012-12-24

    Fixed air quality stations have limitations when used to assess people's real life exposure to air pollutants. Their spatial coverage is too limited to capture the spatial variability in, e.g., an urban or industrial environment. Complementary mobile air quality measurements can be used as an additional tool to fill this void. In this publication we present the Aeroflex, a bicycle for mobile air quality monitoring. The Aeroflex is equipped with compact air quality measurement devices to monitor ultrafine particle number counts, particulate mass and black carbon concentrations at a high resolution (up to 1 second). Each measurement is automatically linked to its geographical location and time of acquisition using GPS and Internet time. Furthermore, the Aeroflex is equipped with automated data transmission, data pre-processing and data visualization. The Aeroflex is designed with adaptability, reliability and user friendliness in mind. Over the past years, the Aeroflex has been successfully used for high resolution air quality mapping, exposure assessment and hot spot identification. 

  10. Quality measures in applications of image restoration.

    PubMed

    Kriete, A; Naim, M; Schafer, L

    2001-01-01

    We describe a new method for the estimation of image quality in image restoration applications. We demonstrate this technique on a simulated data set of fluorescent beads, in comparison with restoration by three different deconvolution methods. Both the number of iterations and a regularisation factor are varied to enforce changes in the resulting image quality. First, the data sets are directly compared by an accuracy measure. These values serve to validate the image quality descriptor, which is developed on the basis of optical information theory. This most general measure takes into account the spectral energies and the noise, weighted in a logarithmic fashion. It is demonstrated that this method is particularly helpful as a user-oriented method to control the output of iterative image restorations and to eliminate the guesswork in choosing a suitable number of iterations.

  11. Real-time video quality monitoring

    NASA Astrophysics Data System (ADS)

    Liu, Tao; Narvekar, Niranjan; Wang, Beibei; Ding, Ran; Zou, Dekun; Cash, Glenn; Bhagavathy, Sitaram; Bloom, Jeffrey

    2011-12-01

    The ITU-T Recommendation G.1070 is a standardized opinion model for video telephony applications that uses video bitrate, frame rate, and packet-loss rate to measure the video quality. However, this model was original designed as an offline quality planning tool. It cannot be directly used for quality monitoring since the above three input parameters are not readily available within a network or at the decoder. And there is a great room for the performance improvement of this quality metric. In this article, we present a real-time video quality monitoring solution based on this Recommendation. We first propose a scheme to efficiently estimate the three parameters from video bitstreams, so that it can be used as a real-time video quality monitoring tool. Furthermore, an enhanced algorithm based on the G.1070 model that provides more accurate quality prediction is proposed. Finally, to use this metric in real-world applications, we present an example emerging application of real-time quality measurement to the management of transmitted videos, especially those delivered to mobile devices.

  12. Quality of care: measuring a neglected driver of improved health

    PubMed Central

    Kruk, Margaret E

    2017-01-01

    Abstract The quality of care provided by health systems contributes towards efforts to reach sustainable development goal 3 on health and well-being. There is growing evidence that the impact of health interventions is undermined by poor quality of care in lower-income countries. Quality of care will also be crucial to the success of universal health coverage initiatives; citizens unhappy with the quality and scope of covered services are unlikely to support public financing of health care. Moreover, an ethical impetus exists to ensure that all people, including the poorest, obtain a minimum quality standard of care that is effective for improving health. However, the measurement of quality today in low- and middle-income countries is inadequate to the task. Health information systems provide incomplete and often unreliable data, and facility surveys collect too many indicators of uncertain utility, focus on a limited number of services and are quickly out of date. Existing measures poorly capture the process of care and the patient experience. Patient outcomes that are sensitive to health-care practices, a mainstay of quality assessment in high-income countries, are rarely collected. We propose six policy recommendations to improve quality-of-care measurement and amplify its policy impact: (i) redouble efforts to improve and institutionalize civil registration and vital statistics systems; (ii) reform facility surveys and strengthen routine information systems; (iii) innovate new quality measures for low-resource contexts; (iv) get the patient perspective on quality; (v) invest in national quality data; and (vi) translate quality evidence for policy impact. PMID:28603313

  13. Measuring quality of care: considering conceptual approaches to quality indicator development and evaluation.

    PubMed

    Stelfox, Henry T; Straus, Sharon E

    2013-12-01

    In this article, we describe one approach for developing and evaluating quality indicators. We focus on describing different conceptual approaches to quality indicator development, review one approach for developing quality indicators, outline how to evaluate quality indicators once developed, and discuss quality indicator maintenance. The key steps for developing quality indicators include specifying a clear goal for the indicators; using methodologies to incorporate evidence, expertise, and patient perspectives; and considering contextual factors and logistics of implementation. The Strategic Framework Board and the National Quality Measure Clearinghouse have developed criteria for evaluating quality indicators that complement traditional psychometric evaluations. Optimal strategies for quality indicator maintenance and dissemination have not been determined, but experiences with clinical guideline maintenance may be informative. For quality indicators to effectively guide quality improvement efforts, they must be developed, evaluated, maintained, and implemented using rigorous evidence-informed practices. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Does exposure to computers affect the routine parameters of semen quality?

    PubMed

    Sun, Yue-Lian; Zhou, Wei-Jin; Wu, Jun-Qing; Gao, Er-Sheng

    2005-09-01

    To assess whether exposure to computers harms the semen quality of healthy young men. A total of 178 subjects were recruited from two maternity and children healthcare centers in Shanghai, 91 with a history of exposure to computers (i.e., exposure for 20 h or more per week in the last 2 years) and 87 persons to act as control (no or little exposure to computers). Data on the history of exposure to computers and other characteristics were obtained by means of a structured questionnaire interview. Semen samples were collected by masturbation in the place where the semen samples were analyzed. No differences in the distribution of the semen parameters (semen volume, sperm density, percentage of progressive sperm, sperm viability and percentage of normal form sperm) were found between the exposed group and the control group. Exposure to computers was not found to be a risk factor for inferior semen quality after adjusting for potential confounders, including abstinence days, testicle size, occupation, history of exposure to toxic substances. The present study did not find that healthy men exposed to computers had inferior semen quality.

  15. Are the CMS Hospital Outpatient Quality Measures Relevant for Rural Hospitals?

    ERIC Educational Resources Information Center

    Casey, Michelle M.; Prasad, Shailendra; Klingner, Jill; Moscovice, Ira

    2012-01-01

    Context: Quality measures focused on outpatient settings are of increasing interest to policy makers, but little research has been conducted on hospital outpatient quality measures, especially in rural settings. Purpose: To evaluate the relevance of Centers for Medicare and Medicaid Services' (CMS) outpatient quality measures for rural hospitals,…

  16. Selection of process parameters for producing high quality defatted sesame flour at pilot scale.

    PubMed

    Manikantan, M R; Sharma, Rajiv; Yadav, D N; Gupta, R K

    2015-03-01

    The present work was undertaken to study the effect of pearling duration, soaking time, steaming duration and drying temperature on the quality of sesame seeds and mechanically extracted partially defatted sesame cake. On the basis of quality attributes i.e. high protein, low crude fibre, low residual oil and low oxalic acid, the optimum process parameters were selected. The combination of 20 min of pearling duration, 15 min of soaking, 15 min of steaming at 100 kPa pressure and drying at 50 °C yielded high quality partially defatted protein rich sesame flour as compared to untreated defatted sesame flour. The developed high quality partially defatted protein rich sesame flour may be used in various food applications as a vital ingredient to increase the nutritional significance of the prepared foodstuffs.

  17. Remote measurements of water pollution with a lidar polarimeter

    NASA Technical Reports Server (NTRS)

    Sheives, T. C.; Rouse, J. W., Jr.; Mayo, W. T., Jr.

    1974-01-01

    This paper examines a dual polarization laser backscatter system as a method for remote measurements of certain water quality parameters. Analytical models for describing the backscatter from turbid water and oil on turbid water are presented and compared with experimental data. Laser backscatter field measurements from natural waterways are presented and compared with simultaneous ground observations of the water quality parameters: turbidity, suspended solids, and transmittance. The results of this study show that the analytical models appear valid and that the sensor investigated is applicable to remote measurements of these water quality parameters and oil spills on water.-

  18. The Need for Comprehensive Health Care Quality Measures for Older Adults.

    PubMed

    MacLeod, Stephanie; Schwebke, Kay; Hawkins, Kevin; Ruiz, Joann; Hoo, Emma; Yeh, Charlotte S

    2017-10-24

    Research indicates that older adults receive only about half of their recommended care, with varying quality and limited attention to social issues impacting their health through the most commonly used quality measures. Additionally, many existing measures neglect to address nonclinical social determinants of health. Evidence of the need for more comprehensive measures for seniors is growing. The primary purpose of this article, which is supported by a limited review of literature, is to describe gaps among current quality measures in addressing certain nonclinical needs of older adults, including key social determinants of health. In doing so, the authors describe their position on the need for expanded measures to incorporate these factors to improve care and quality of life. The authors conducted a limited review of the literature to inform this article, focusing specifically on selected measures for older adults rather than a broader systematic review of all measures. Most research identified was related to clinical practice guidelines rather than quality measures of care as applied to older adults. Furthermore, the literature reviewed reflected limited evidence of efforts to tailor quality measures for the unique social needs of older adults, confirming a potential gap in this area. A growing need exists for improved quality measures specifically designed to help providers address the unique social needs of older adults. Filling this gap will improve overall understanding of seniors and help them to achieve optimal health and successful aging.

  19. Distributed sensor architecture for intelligent control that supports quality of control and quality of service.

    PubMed

    Poza-Lujan, Jose-Luis; Posadas-Yagüe, Juan-Luis; Simó-Ten, José-Enrique; Simarro, Raúl; Benet, Ginés

    2015-02-25

    This paper is part of a study of intelligent architectures for distributed control and communications systems. The study focuses on optimizing control systems by evaluating the performance of middleware through quality of service (QoS) parameters and the optimization of control using Quality of Control (QoC) parameters. The main aim of this work is to study, design, develop, and evaluate a distributed control architecture based on the Data-Distribution Service for Real-Time Systems (DDS) communication standard as proposed by the Object Management Group (OMG). As a result of the study, an architecture called Frame-Sensor-Adapter to Control (FSACtrl) has been developed. FSACtrl provides a model to implement an intelligent distributed Event-Based Control (EBC) system with support to measure QoS and QoC parameters. The novelty consists of using, simultaneously, the measured QoS and QoC parameters to make decisions about the control action with a new method called Event Based Quality Integral Cycle. To validate the architecture, the first five Braitenberg vehicles have been implemented using the FSACtrl architecture. The experimental outcomes, demonstrate the convenience of using jointly QoS and QoC parameters in distributed control systems.

  20. Distributed Sensor Architecture for Intelligent Control that Supports Quality of Control and Quality of Service

    PubMed Central

    Poza-Lujan, Jose-Luis; Posadas-Yagüe, Juan-Luis; Simó-Ten, José-Enrique; Simarro, Raúl; Benet, Ginés

    2015-01-01

    This paper is part of a study of intelligent architectures for distributed control and communications systems. The study focuses on optimizing control systems by evaluating the performance of middleware through quality of service (QoS) parameters and the optimization of control using Quality of Control (QoC) parameters. The main aim of this work is to study, design, develop, and evaluate a distributed control architecture based on the Data-Distribution Service for Real-Time Systems (DDS) communication standard as proposed by the Object Management Group (OMG). As a result of the study, an architecture called Frame-Sensor-Adapter to Control (FSACtrl) has been developed. FSACtrl provides a model to implement an intelligent distributed Event-Based Control (EBC) system with support to measure QoS and QoC parameters. The novelty consists of using, simultaneously, the measured QoS and QoC parameters to make decisions about the control action with a new method called Event Based Quality Integral Cycle. To validate the architecture, the first five Braitenberg vehicles have been implemented using the FSACtrl architecture. The experimental outcomes, demonstrate the convenience of using jointly QoS and QoC parameters in distributed control systems. PMID:25723145

  1. Effect of Pulse Parameters on Weld Quality in Pulsed Gas Metal Arc Welding: A Review

    NASA Astrophysics Data System (ADS)

    Pal, Kamal; Pal, Surjya K.

    2011-08-01

    The weld quality comprises bead geometry and its microstructure, which influence the mechanical properties of the weld. The coarse-grained weld microstructure, higher heat-affected zone, and lower penetration together with higher reinforcement reduce the weld service life in continuous mode gas metal arc welding (GMAW). Pulsed GMAW (P-GMAW) is an alternative method providing a better way for overcoming these afore mentioned problems. It uses a higher peak current to allow one molten droplet per pulse, and a lower background current to maintain the arc stability. Current pulsing refines the grains in weld fusion zone with increasing depth of penetration due to arc oscillations. Optimum weld joint characteristics can be achieved by controlling the pulse parameters. The process is versatile and easily automated. This brief review illustrates the effect of pulse parameters on weld quality.

  2. Effects of Irradiation Dose on Sterility Induction and Quality Parameters of Drosophila suzukii (Diptera: Drosophilidae).

    PubMed

    Krüger, Alexandra Peter; Schlesener, Daniele Cristine Hoffmann; Martins, Liliane Nachtigall; Wollmann, Jutiane; Deprá, Maríndia; Garcia, Flávio Roberto Mello

    2018-04-02

    Drosophila suzukii (Matsumura, 1931) (Diptera: Drosophilidae) is a widely distributed pest of soft-skinned and stone fruits that is controlled mainly with pesticides. An alternative to the chemical control is the sterile insect technique (SIT), an ecologically friendly method of pest management that could be used against D. suzukii. The objective of the present study was to evaluate the effects of gamma radiation on reproductive sterility, ovarian morphometry, and quality parameters of D. suzukii. Full female sterility was achieved at 75 Gy, while an adequate level of male sterility (99.67%) was obtained at 200 Gy. The ovarian size showed an exponential decay in function of irradiation dose increase. There was no significant influence of irradiation dose on the quality parameters evaluated. Our data suggest that gamma radiation can be recommended to be used in an SIT program for D. suzukii.

  3. Texas Water Quality Board Teachers Workshop Program.

    ERIC Educational Resources Information Center

    Texas Water Quality Board, Austin.

    These materials are designed for teachers participating in an inservice workshop on water quality. Included in the materials are a workshop agenda, a water awareness pretest, and the various parameters and tests that are used to determine and measure water quality. The parameters are discussed from the standpoint of their potential impact to…

  4. Identification of Important Parameter from Leachate Solid Waste Landfill on Water Quality, Case Study of Pesanggrahan River

    NASA Astrophysics Data System (ADS)

    Yanidar, R.; Hartono, D. M.; Moersidik, S. S.

    2018-03-01

    Cipayung Landfill takes waste generation from Depok City approximately ± 750 tons/day of solid waste. The south and west boundaries of the landfill is Pesanggarahan River which 200m faraway. The objectives of this study are to indicate an important parameter which greatly affects the water quality of Pesanggrahan River and purpose the dynamic model for improving our understanding of the dynamic behavior that captures the interactions and feedbacks important parameter in river in order to identify and assess the effects of the treated leachate from final solid waste disposal activity as it responds to changes over time in the river. The high concentrations of BOD and COD are not the only cause significantly affect the quality of the pesanggrahan water, it also because the river has been contaminated in the upstream area. It need the water quality model to support the effectiveness calculation of activities for preventing a selected the pollutant sources the model should be developed for simulating and predicting the trend of water quality performance in Pesanggrahan River which can potentially be used by policy makers in strategic management to sustain river water quality as raw drinking water.

  5. Quality control algorithms for rainfall measurements

    NASA Astrophysics Data System (ADS)

    Golz, Claudia; Einfalt, Thomas; Gabella, Marco; Germann, Urs

    2005-09-01

    One of the basic requirements for a scientific use of rain data from raingauges, ground and space radars is data quality control. Rain data could be used more intensively in many fields of activity (meteorology, hydrology, etc.), if the achievable data quality could be improved. This depends on the available data quality delivered by the measuring devices and the data quality enhancement procedures. To get an overview of the existing algorithms a literature review and literature pool have been produced. The diverse algorithms have been evaluated to meet VOLTAIRE objectives and sorted in different groups. To test the chosen algorithms an algorithm pool has been established, where the software is collected. A large part of this work presented here is implemented in the scope of the EU-project VOLTAIRE ( Validati on of mu ltisensors precipit ation fields and numerical modeling in Mediter ran ean test sites).

  6. Measurement of the Michel rho parameter in direct muon decay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Piilonen, Leo; Haim, D.; Zhang, Y.

    1997-05-01

    We report on the status of LAMPF experiment E-1240 to measure the Michel {rho} parameter in direct muon decay. This experiment ran in 1993, and the data are currently being analyzed. The expected precision on the {rho} parameter is {plus_minus}0.0008. This result will provide better constraints on new physics, particularly on the charged vector bosons{close_quote} mixing angle {zeta} in the manifestly left-right symmetric extension of the Standard Model. {copyright} {ital 1997 American Institute of Physics.}

  7. Airborne cloud condensation nuclei measurements during the 2006 Texas Air Quality Study

    NASA Astrophysics Data System (ADS)

    Asa-Awuku, Akua; Moore, Richard H.; Nenes, Athanasios; Bahreini, Roya; Holloway, John S.; Brock, Charles A.; Middlebrook, Ann M.; Ryerson, Thomas B.; Jimenez, Jose L.; Decarlo, Peter F.; Hecobian, Arsineh; Weber, Rodney J.; Stickel, Robert; Tanner, Dave J.; Huey, Lewis G.

    2011-06-01

    Airborne measurements of aerosol and cloud condensation nuclei (CCN) were conducted aboard the National Oceanic and Atmospheric Administration WP-3D platform during the 2006 Texas Air Quality Study/Gulf of Mexico Atmospheric Composition and Climate Study (TexAQS/GoMACCS). The measurements were conducted in regions influenced by industrial and urban sources. Observations show significant local variability of CCN activity (CCN/CN from 0.1 to 0.5 at s = 0.43%), while variability is less significant across regional scales (˜100 km × 100 km; CCN/CN is ˜0.1 at s = 0.43%). CCN activity can increase with increasing plume age and oxygenated organic fraction. CCN measurements are compared to predictions for a number of mixing state and composition assumptions. Mixing state assumptions that assumed internally mixed aerosol predict CCN concentrations well. Assuming organics are as hygroscopic as ammonium sulfate consistently overpredicted CCN concentrations. On average, the water-soluble organic carbon (WSOC) fraction is 60 ± 14% of the organic aerosol. We show that CCN closure can be significantly improved by incorporating knowledge of the WSOC fraction with a prescribed organic hygroscopicity parameter (κ = 0.16 or effective κ ˜ 0.3). This implies that the hygroscopicity of organic mass is primarily a function of the WSOC fraction. The overall aerosol hygroscopicity parameter varies between 0.08 and 0.88. Furthermore, droplet activation kinetics are variable and 60% of particles are smaller than the size characteristic of rapid droplet growth.

  8. Rapid core measure improvement through a "business case for quality".

    PubMed

    Perlin, Jonathan B; Horner, Stephen J; Englebright, Jane D; Bracken, Richard M

    2014-01-01

    Incentives to improve performance are emerging as revenue or financial penalties are linked to the measured quality of service provided. The HCA "Getting to Green" program was designed to rapidly increase core measure performance scores. Program components included (1) the "business case for quality"-increased awareness of how quality drives financial performance; (2) continuous communication of clinical and financial performance data; and (3) evidence-based clinical protocols, incentives, and tools for process improvement. Improvement was measured by comparing systemwide rates of adherence to national quality measures for heart failure (HF), acute myocardial infarction (AMI), pneumonia (PN), and surgical care (SCIP) to rates from all facilities reporting to the Centers for Medicare and Medicaid Services (CMS). As of the second quarter of 2011, 70% of HCA total measure set composite scores were at or above the 90th percentile of CMS scores. A test of differences in regression coefficients between the CMS national average and the HCA average revealed significant differences for AMI (p = .001), HF (p = .012), PN (p < .001), and SCIP (p = .015). This program demonstrated that presentation of the financial implications of quality, transparency in performance data, and clearly defined goals could cultivate the desire to use improvement tools and resources to raise performance. © 2012 National Association for Healthcare Quality.

  9. Patients’ perceived value of pharmacy quality measures: a mixed-methods study

    PubMed Central

    Shiyanbola, Olayinka O; Mort, Jane R

    2015-01-01

    Objective To describe patients’ perceived value and use of quality measures in evaluating and choosing community pharmacies. Design Focus group methodology was combined with a survey tool. During the focus groups, participants assessed the value of the Pharmacy Quality Alliance's quality measures in evaluating and choosing a pharmacy. Also, participants completed questionnaires rating their perceived value of quality measures in evaluating a pharmacy (1 being low value and 5 being high) or choosing a pharmacy (yes/no). Thematic analysis and descriptive statistics were used to analyse the focus groups and surveys, respectively. Setting Semistructured focus groups were conducted in a private meeting space of an urban and a rural area of a Mid-western State in the USA. Participants Thirty-four adults who filled prescription medications in community pharmacies for a chronic illness were recruited in community pharmacies, senior centres and public libraries. Results While comments indicated that all measures were important, medication safety measures (eg, drug-drug interactions) were valued more highly than others. Rating of quality measure utility in evaluating a pharmacy ranged from a mean of 4.88 (‘drug-drug interactions’) to a mean of 4.0 (‘absence of controller therapy for patients with asthma’). Patients were hesitant to use quality information in choosing a pharmacy (depending on the participant's location) but might consider if moving to a new area or having had a negative pharmacy experience. Use of select quality measures to choose a pharmacy ranged from 97.1% of participants using ‘drug-drug interactions’ (medication safety measure) to 55.9% using ‘absence of controller therapy for patients with asthma’. Conclusions The study participants valued quality measures in evaluating and selecting a community pharmacy, with medication safety measures valued highest. The participants reported that the quality measures would not typically cause a

  10. Value of semen parameters, with special reference to TNF-α, in predicting the quality of boar semen after short-term storage.

    PubMed

    Mrkun, Janko; Kosec, Marjan; Zrimšek, Petra

    2013-06-01

    The aim of this study was to address the question whether changes in boar semen quality after short-term storage could be predicted on the basis of standard semen parameters and TNF-α level determined on the day of semen collection under commercial conditions. Progressive motility showed the highest positive correlation with morphology on day 0 of collection, and progressive motility on day 3 (P < 0.05) showed a negative correlation with acrosome abnormalities (P < 0.05). According to the area under receiver operating characteristics (ROC) curves (AUCs), progressive motility could also be used in predicting semen quality after 3 days of storage (AUC > 0.5; P < 0.05). TNF-α in seminal plasma is the only parameter measured on day 0 to show a significant correlation with the percentage of viable spermatozoa after 3 days of semen storage (r = 0.495, P < 0.05). ROC analysis shows that TNF-α level is helpful in discriminating viability outcome after semen storage (AUC = 0.94, P < 0.001). We can predict with 92.35% certainty that fresh semen samples with more than 150 pg/ml of TNF-α in the seminal plasma will retain more than 85% of viable spermatozoa after 3 days of storage. Thus, TNF-α can contribute to predicting the quality of short-term stored semen.

  11. Comparative evaluation of two asthma care quality measures among Medicaid beneficiaries.

    PubMed

    Samnaliev, Mihail; Baxter, Jeffrey D; Clark, Robin E

    2009-05-01

    The relative performance of asthma care quality measures has not been evaluated in Medicaid populations. Using complete claims and pharmaceutical data for 19,076 patients with persistent asthma (based on Health Effectiveness and Data Information Set criteria) in five Medicaid populations, we compared the following two measures of asthma care quality: filling prescriptions for controller asthma medications within 1 year and the ratio of controller medication to the total number of asthma medication prescriptions filled within 1 year. We calculated whether meeting each quality measure was associated with decreased odds of emergency department (ED) treatment episodes. We then compared the odds ratios, receiver operating characteristic (ROC) curves, and deviances between models, using each measure to predict ED utilization in Medicaid populations. Although meeting each measure was associated with lower odds of ED utilization, this decrease was larger if the controller asthma medication measure was met rather than the ratio measure. Additionally, models using the controller medication measure had greater areas under the ROC curve and smaller deviances than models using the ratio measure. Both administrative measures of asthma care quality were associated with lower odds of ED utilization. The controller medication measure of asthma care quality may be better than the ratio measure in relation to emergency asthma care utilization by Medicaid beneficiaries.

  12. Quantitative Determination of Spring Water Quality Parameters via Electronic Tongue

    PubMed Central

    Carbó, Noèlia; López Carrero, Javier; Garcia-Castillo, F. Javier; Olivas, Estela; Folch, Elisa; Alcañiz Fillol, Miguel; Soto, Juan

    2017-01-01

    The use of a voltammetric electronic tongue for the quantitative analysis of quality parameters in spring water is proposed here. The electronic voltammetric tongue consisted of a set of four noble electrodes (iridium, rhodium, platinum, and gold) housed inside a stainless steel cylinder. These noble metals have a high durability and are not demanding for maintenance, features required for the development of future automated equipment. A pulse voltammetry study was conducted in 83 spring water samples to determine concentrations of nitrate (range: 6.9–115 mg/L), sulfate (32–472 mg/L), fluoride (0.08–0.26 mg/L), chloride (17–190 mg/L), and sodium (11–94 mg/L) as well as pH (7.3–7.8). These parameters were also determined by routine analytical methods in spring water samples. A partial least squares (PLS) analysis was run to obtain a model to predict these parameter. Orthogonal signal correction (OSC) was applied in the preprocessing step. Calibration (67%) and validation (33%) sets were selected randomly. The electronic tongue showed good predictive power to determine the concentrations of nitrate, sulfate, chloride, and sodium as well as pH and displayed a lower R2 and slope in the validation set for fluoride. Nitrate and fluoride concentrations were estimated with errors lower than 15%, whereas chloride, sulfate, and sodium concentrations as well as pH were estimated with errors below 10%. PMID:29295592

  13. Estimating parameters from rotating ring disc electrode measurements

    DOE PAGES

    Santhanagopalan, Shriram; White, Ralph E.

    2017-10-21

    Rotating ring disc electrode (RRDE) experiments are a classic tool for investigating kinetics of electrochemical reactions. Several standardized methods exist for extracting transport parameters and reaction rate constants using RRDE measurements. Here in this work, we compare some approximate solutions to the convective diffusion used popularly in the literature to a rigorous numerical solution of the Nernst-Planck equations coupled to the three dimensional flow problem. In light of these computational advancements, we explore design aspects of the RRDE that will help improve sensitivity of our parameter estimation procedure to experimental data. We use the oxygen reduction in acidic media involvingmore » three charge transfer reactions and a chemical reaction as an example, and identify ways to isolate reaction currents for the individual processes in order to accurately estimate the exchange current densities.« less

  14. Operational military helicopter interior noise and vibration measurements with comparisons to ride quality criteria

    NASA Technical Reports Server (NTRS)

    Clevenson, S. A.; Leatherwood, J. D.; Hollenbaugh, D. D.

    1983-01-01

    Balka (1981) has identified the attainment of a 'jet-smooth' ride as a primary goal of the helicopter industry for commercial and certain military helicopters. It was noted that criteria accounting for both multiple axis vibration and interior noise are needed. The present investigation has the objective to present a vibration and interior noise data base in a format suitable for direct evaluation of aircraft ride quality. The investigation is also concerned with an assessment of the measured environment against available criteria as an indication of the state-of-the-art for current machines. Interior noise and vibration measurements were obtained on eight military helicopters during routine operational flights. The data are presented in the form of a number of parameters.

  15. Modelling of groundwater quality using bicarbonate chemical parameter in Netravathi and Gurpur river confluence, India

    NASA Astrophysics Data System (ADS)

    Sylus, K. J.; H., Ramesh

    2018-04-01

    In the coastal aquifer, seawater intrusion considered the major problem which contaminates freshwater and reduces its quality for domestic use. In order to find seawater intrusion, the groundwater quality analysis for the different chemical parameter was considered as the basic method to find out contamination. This analysis was carried out as per Bureau of Indian standards (2012) and World Health Organisations (1996). In this study, Bicarbonate parameter was considered for groundwater quality analysis which ranges the permissible limit in between 200-600 mg/l. The groundwater system was modelled using Groundwater modelling software (GMS) in which the FEMWATER package used for flow and transport. The FEMWATER package works in the principle of finite element method. The base input data of model include elevation, Groundwater head, First bottom and second bottom of the study area. The modelling results show the spatial occurrence of contamination in the study area of Netravathi and Gurpur river confluence at the various time period. Further, the results of the modelling also show that the contamination occurs up to a distance of 519m towards the freshwater zone of the study area.

  16. e-Measures: insight into the challenges and opportunities of automating publicly reported quality measures

    PubMed Central

    Garrido, Terhilda; Kumar, Sudheen; Lekas, John; Lindberg, Mark; Kadiyala, Dhanyaja; Whippy, Alan; Crawford, Barbara; Weissberg, Jed

    2014-01-01

    Using electronic health records (EHR) to automate publicly reported quality measures is receiving increasing attention and is one of the promises of EHR implementation. Kaiser Permanente has fully or partly automated six of 13 the joint commission measure sets. We describe our experience with automation and the resulting time savings: a reduction by approximately 50% of abstractor time required for one measure set alone (surgical care improvement project). However, our experience illustrates the gap between the current and desired states of automated public quality reporting, which has important implications for measure developers, accrediting entities, EHR vendors, public/private payers, and government. PMID:23831833

  17. Measuring Software Product Quality: The ISO 25000 Series and CMMI

    DTIC Science & Technology

    2004-06-14

    performance objectives” covers objectives and requirements for product quality, service quality , and process performance. Process performance objectives...such that product quality, service quality , and process performance attributes are measurable and controlled throughout the project (internal and

  18. Quality Measures for the Care of Adult Patients with Obstructive Sleep Apnea

    PubMed Central

    Aurora, R. Nisha; Collop, Nancy A.; Jacobowitz, Ofer; Thomas, Sherene M.; Quan, Stuart F.; Aronsky, Amy J.

    2015-01-01

    Obstructive sleep apnea (OSA) is a prevalent disorder associated with a multitude of adverse outcomes when left untreated. There is significant heterogeneity in the evaluation and management of OSA resulting in variation in cost and outcomes. Thus, the goal for developing these measures was to have a way to evaluate the outcomes and reliability of the processes involved with the standard care approaches used in the diagnosis and management of OSA. The OSA quality care measures presented here focus on both outcomes and processes. The AASM commissioned the Adult OSA Quality Measures Workgroup to develop quality care measures aimed at optimizing care for adult patients with OSA. These quality care measures developed by the Adult OSA Quality Measures Workgroup are an extension of the original Centers for Medicare & Medicaid Services (CMS) approved Physician Quality Reporting System (PQRS) measures group for OSA. The measures are based on the available scientific evidence, focus on public safety, and strive to improve quality of life and cardiovascular outcomes for individual OSA patients. The three outcomes that were selected were as follows: (1) improve disease detection and categorization; (2) improve quality of life; and (3) reduce cardiovascular risk. After selecting these relevant outcomes, a total of ten process measures were chosen that could be applied and assessed for the purpose of accomplishing these outcomes. In the future, the measures described in this document may be reported through the PQRS in addition to, or as a replacement for, the current OSA measures group. The overall objective for the development of these measures is that implementation of these quality measures will result in improved patient outcomes, reduce the public health burden of OSA, and provide a measurable standard for evaluating and managing OSA. Citation: Aurora RN, Collop NA, Jacobowitz O, Thomas SM, Quan SF, Aronsky AJ. Quality measures for the care of adult patients with

  19. National Quality Measures for Child Mental Health Care: Background, Progress, and Next Steps

    PubMed Central

    Murphy, J. Michael; Scholle, Sarah Hudson; Hoagwood, Kimberly Eaton; Sachdeva, Ramesh C.; Mangione-Smith, Rita; Woods, Donna; Kamin, Hayley S.; Jellinek, Michael

    2013-01-01

    OBJECTIVE: To review recent health policies related to measuring child health care quality, the selection processes of national child health quality measures, the nationally recommended quality measures for child mental health care and their evidence strength, the progress made toward developing new measures, and early lessons learned from these national efforts. METHODS: Methods used included description of the selection process of child health care quality measures from 2 independent national initiatives, the recommended quality measures for child mental health care, and the strength of scientific evidence supporting them. RESULTS: Of the child health quality measures recommended or endorsed during these national initiatives, only 9 unique measures were related to child mental health. CONCLUSIONS: The development of new child mental health quality measures poses methodologic challenges that will require a paradigm shift to align research with its accelerated pace. PMID:23457148

  20. Impact of sodium chloride on wheat flour dough for yeast-leavened products. II. Baking quality parameters and their relationship.

    PubMed

    Beck, Margit; Jekle, Mario; Becker, Thomas

    2012-01-30

    The traditional use of sodium chloride (NaCl) fulfills various important rheological, technological and sensory properties in the manufacturing of yeast-leavened products. However, the use of NaCl in food production has been discussed controversially since a high intake of sodium seems to be associated with hypertension. This study investigates the baking quality parameters of wheat breads containing various levels of NaCl (0-40 g NaCl kg(-1) flour). Crumb firmness and rate of bread staling decreased with decreasing NaCl levels. A slight increase in loaf volume was observed based on the increased yeast leavening ability resulting from additional NaCl. Higher crumb retrogradation (measured by differential scanning calorimetry) was observed with low NaCl levels. The retrogradation effect is based on the theory that NaCl probably leads to Na(+) inclusion in starch molecules during storage and thus reduces retrogradation. Further, significant (P⩽0.05) linear relationships (r ≥ 0.829) between Rheofermentometer results, bread volume and crumb firmness were found, suggesting a predictability of bread quality by measurement of gas release. Copyright © 2011 Society of Chemical Industry.

  1. Improvement in quality-of-life questionnaire measures in obese adolescent females with polycystic ovary syndrome treated with lifestyle changes and oral contraceptives, with or without metformin.

    PubMed

    Harris-Glocker, Miranda; Davidson, Kristin; Kochman, Lynda; Guzick, David; Hoeger, Kathleen

    2010-02-01

    We studied the effect of metformin or placebo in a lifestyle modification program combined with oral contraceptives (OC) on quality-of-life parameters measured by the polycystic ovary syndrome (PCOS) questionnaire in obese adolescent women with validated PCOS. The quality-of-life indicators were measured at baseline and conclusion for five domains on the PCOS questionnaire, with equal improvement in scores in both placebo and metformin groups, suggesting that the addition of metformin does not add improvement to quality-of-life measures above those observed with lifestyle modification and OC treatment. Copyright 2010 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  2. Water quality parameters response to temperature change in small shallow lakes

    NASA Astrophysics Data System (ADS)

    Xu, Lei; Li, Hua; Liang, Xinqiang; Yao, Yuxin; Zhou, Li; Cui, Xinyi

    Effects of temperature (T) on water quality of three small shallow lakes in Taihu Lake region of China were investigated. The annual temperature was classified into three levels: low temperature (LT, 4 °C < T ⩽ 10 °C), middle temperature (MT, 10 °C < T ⩽ 20 °C), and high temperature (HT, 20 °C < T ⩽ 30 °C). Results showed that total nitrogen (TN) and total phosphorus (TP) concentrations might go to a fixed value (or range) in small shallow lakes receiving domestic sewage and farm drainage water. Nitrogen concentrations in the lakes were mainly in the form of nitrate (NO3-) at above concerned three temperature levels, and nitrogen concentrations in the forms of TN, TIN, and NO3- were increased with the increase of nutrient input. At the LT and MT levels, there was a series of good cubic curve relationships between temperatures and three N forms (TN, NO3- and NH4+). The temperatural inflexion change points in the curves were nearly at 7 °C and 14 °C, respectively. However, no significant relationship between temperature and any water quality parameter was observed at the HT level. The significant relationship of TIN to TN, NO3- to TN and NH4+ to dissolve oxygen (DO) was exist in three temperature portions, and TP to Chemical oxygen demand (COD, determined by potassium permanganate oxidation methods) in LT and MT, TP to pH or DO in HT also exist. COD were less than 6 mg L-1 at each temperature level, and pH values were the largest in HT than it in LT or MT. Thus, changes between temperature and water quality parameters (TN, NO3-, NH4+ and TP) obviously nearly in 7 °C or 14 °C in lakes show that water self-purification of natural small shallow lakes were obviously with temperature changed.

  3. Perioperative versus postoperative measurement of Taylor Spatial Frame mounting parameters.

    PubMed

    Sökücü, Sami; Demir, Bilal; Lapçin, Osman; Yavuz, Umut; Kabukçuoğlu, Yavuz S

    2014-01-01

    The aim of this study was to determine the differences, if any, between application parameters for the Taylor Spatial Frame (TSF) system obtained during surgery under fluoroscopy and after surgery from digital radiography. This retrospective study included 17 extremities of 15 patients (8 male, 7 female; mean age: 21.9 years, range: 10 to 55 years) who underwent TSF after deformity and fracture. Application parameters measured by fluoroscopy at the end of surgery after mounting the fixator were compared with parameters obtained from anteroposterior and lateral digital radiographs taken 1 day after surgery. Fixator was applied to the femur in 8 patients, tibia in 6 and radius in 3. Mean time to removal of the frame was 3.5 (range: 3 to 7) months. Mean perioperative anteroposterior, lateral and axial frame offsets of patients were 9.1 (range: 3 to 20) mm, 18.1 (range: 5 to 37) mm and 95.3 (range: 25 to 155) mm, respectively. Mean postoperative anteroposterior, lateral and axial frame offset radiographs were 11.8 (range: 2 to 30) mm, 18 (range: 6 to 47) mm and 109.5 (range: 28 to 195) mm, respectively. There was no statistically significant difference between the groups (p>0.05). While measurements taken during operation may lengthen the duration in the operation room, fluoroscopy may provide better images and is easier to perform than digital radiography. On the other hand, there is no difference between measurements taken during perioperative fluoroscopy and postoperative digital radiography.

  4. COMPUTERIZED NEEDS-ORIENTED QUALITY MEASUREMENT EVALUATION SYSTEM (CONQUEST)

    EPA Science Inventory

    CONQUEST is an easy-to-use quality improvement software tool that uses a common structure and language to help users identity, understand, compare, evaluate, and select among 1,200 clinical performance measures that can be used to assess and improve quality of care. CONQUEST's in...

  5. Corneal biomechanical data and biometric parameters measured with Scheimpflug-based devices on normal corneas.

    PubMed

    Nemeth, Gabor; Szalai, Eszter; Hassan, Ziad; Lipecz, Agnes; Flasko, Zsuzsa; Modis, Laszlo

    2017-01-01

    To analyze the correlations between ocular biomechanical and biometric data of the eye, measured by Scheimpflug-based devices on healthy subjects. Three consecutive measurements were carried out using the corneal visualization Scheimpflug technology (CorVis ST) device on healthy eyes and the 10 device-specific parameters were recorded. Pentacam HR-derived parameters (corneal curvature radii on the anterior and posterior surfaces; apical pachymetry; corneal volume; corneal aberration data; depth, volume and angle of the anterior chamber) and axial length (AL) from IOLMaster were correlated with the 10 specific CorVis ST parameters. Measurements were conducted in 43 eyes of 43 volunteers (age 61.24±15.72y). The 10 specific CorVis ST data showed significant relationships with corneal curvature radii both on the anterior and posterior surface, pachymetric data, root mean square (RMS) data of lower-order aberrations, and posterior RMS of higher-order aberrations and spherical aberration of the posterior cornea. Anterior chamber depth showed a significant relationship, but there were no significant correlations between corneal volume, anterior chamber volume, mean chamber angle or AL and the 10 specific CorVis ST parameters. CorVis ST-generated parameters are influenced by corneal curvature radii, some corneal RMS data, but corneal volume, anterior chamber volume, chamber angle and AL have no correlation with the biomechanical parameters. The parameters measured by CorVis ST seem to refer mostly to corneal properties of the eye.

  6. Corneal biomechanical data and biometric parameters measured with Scheimpflug-based devices on normal corneas

    PubMed Central

    Nemeth, Gabor; Szalai, Eszter; Hassan, Ziad; Lipecz, Agnes; Flasko, Zsuzsa; Modis, Laszlo

    2017-01-01

    AIM To analyze the correlations between ocular biomechanical and biometric data of the eye, measured by Scheimpflug-based devices on healthy subjects. METHODS Three consecutive measurements were carried out using the corneal visualization Scheimpflug technology (CorVis ST) device on healthy eyes and the 10 device-specific parameters were recorded. Pentacam HR-derived parameters (corneal curvature radii on the anterior and posterior surfaces; apical pachymetry; corneal volume; corneal aberration data; depth, volume and angle of the anterior chamber) and axial length (AL) from IOLMaster were correlated with the 10 specific CorVis ST parameters. RESULTS Measurements were conducted in 43 eyes of 43 volunteers (age 61.24±15.72y). The 10 specific CorVis ST data showed significant relationships with corneal curvature radii both on the anterior and posterior surface, pachymetric data, root mean square (RMS) data of lower-order aberrations, and posterior RMS of higher-order aberrations and spherical aberration of the posterior cornea. Anterior chamber depth showed a significant relationship, but there were no significant correlations between corneal volume, anterior chamber volume, mean chamber angle or AL and the 10 specific CorVis ST parameters. CONCLUSIONS CorVis ST-generated parameters are influenced by corneal curvature radii, some corneal RMS data, but corneal volume, anterior chamber volume, chamber angle and AL have no correlation with the biomechanical parameters. The parameters measured by CorVis ST seem to refer mostly to corneal properties of the eye. PMID:28251079

  7. The Relationship between Health Plan Performance Measures and Physician Network Overlap: Implications for Measuring Plan Quality

    PubMed Central

    Maeng, Daniel D; Scanlon, Dennis P; Chernew, Michael E; Gronniger, Tim; Wodchis, Walter P; McLaughlin, Catherine G

    2010-01-01

    Objective To examine the extent to which health plan quality measures capture physician practice patterns rather than plan characteristics. Data Source We gathered and merged secondary data from the following four sources: a private firm that collected information on individual physicians and their health plan affiliations, The National Committee for Quality Assurance, InterStudy, and the Dartmouth Atlas. Study Design We constructed two measures of physician network overlap for all health plans in our sample and linked them to selected measures of plan performance. Two linear regression models were estimated to assess the relationship between the measures of physician network overlap and the plan performance measures. Principal Findings The results indicate that in the presence of a higher degree of provider network overlap, plan performance measures tend to converge to a lower level of quality. Conclusions Standard health plan performance measures reflect physician practice patterns rather than plans' effort to improve quality. This implies that more provider-oriented measurement, such as would be possible with accountable care organizations or medical homes, may facilitate patient decision making and provide further incentives to improve performance. PMID:20403064

  8. Rapid algorithm prototyping and implementation for power quality measurement

    NASA Astrophysics Data System (ADS)

    Kołek, Krzysztof; Piątek, Krzysztof

    2015-12-01

    This article presents a Model-Based Design (MBD) approach to rapidly implement power quality (PQ) metering algorithms. Power supply quality is a very important aspect of modern power systems and will become even more important in future smart grids. In this case, maintaining the PQ parameters at the desired level will require efficient implementation methods of the metering algorithms. Currently, the development of new, advanced PQ metering algorithms requires new hardware with adequate computational capability and time intensive, cost-ineffective manual implementations. An alternative, considered here, is an MBD approach. The MBD approach focuses on the modelling and validation of the model by simulation, which is well-supported by a Computer-Aided Engineering (CAE) packages. This paper presents two algorithms utilized in modern PQ meters: a phase-locked loop based on an Enhanced Phase Locked Loop (EPLL), and the flicker measurement according to the IEC 61000-4-15 standard. The algorithms were chosen because of their complexity and non-trivial development. They were first modelled in the MATLAB/Simulink package, then tested and validated in a simulation environment. The models, in the form of Simulink diagrams, were next used to automatically generate C code. The code was compiled and executed in real-time on the Zynq Xilinx platform that combines a reconfigurable Field Programmable Gate Array (FPGA) with a dual-core processor. The MBD development of PQ algorithms, automatic code generation, and compilation form a rapid algorithm prototyping and implementation path for PQ measurements. The main advantage of this approach is the ability to focus on the design, validation, and testing stages while skipping over implementation issues. The code generation process renders production-ready code that can be easily used on the target hardware. This is especially important when standards for PQ measurement are in constant development, and the PQ issues in emerging smart

  9. LiDAR for Air Quality Measurements

    DOT National Transportation Integrated Search

    2017-02-02

    The overall goal of this research is to investigate a unique light detection and ranging (LiDAR) technology for ambient air quality measurement of particulate matter. The ODU team has recently received a state-of-the-art elastic LiDAR from NASA Langl...

  10. New Measurement of Ξ-→Λπ- Decay Parameters

    NASA Astrophysics Data System (ADS)

    Huang, M.; Burnstein, R. A.; Chakravorty, A.; Chen, Y. C.; Choong, W. S.; Clark, K.; Dukes, E. C.; Durandet, C.; Felix, J.; Gidal, G.; Gustafson, H. R.; Holmstrom, T.; James, C.; Jenkins, C. M.; Jones, T.; Kaplan, D. M.; Lederman, L. M.; Leros, N.; Longo, M. J.; Lopez, Fred; Lu, L.; Luebke, W.; Luk, K. B.; Nelson, K. S.; Park, H. K.; Perroud, J. P.; Rajaram, D.; Rubin, H. A.; Volk, J.; White, C.; White, S.; Zyla, P.

    2004-06-01

    Based on a sample of 144×106 polarized Ξ-→Λπ-,Λ→pπ- decays collected by the HyperCP experiment (E871) at Fermilab, we report a new measurement of the Ξ- decay-parameter angle φΞ=(-2.39±0.64±0.64)° from which we deduce the decay parameters βΞ=-0.037±0.011±0.010 and γΞ=0.888±0.0004±0.006. Assuming that the CP-violating phase difference between s and p waves is negligible, the strong phase-shift difference, δp-δs, for Λπ scattering is determined to be (4.6±1.4±1.2)°.

  11. The measurement of quality of care in the Veterans Health Administration.

    PubMed

    Halpern, J

    1996-03-01

    The Veterans Health Administration (VHA) is committed to continual refinement of its system of quality measurement. The VHA organizational structure for quality measurement has three levels. At the national level, the Associate Chief Medical Director for Quality Management provides leadership, sets policy, furnishes measurement tools, develops and distributes measures of quality, and delivers educational programs. At the intermediate level, VHA has four regional offices with staff responsible for reviewing risk management data, investigating quality problems, and ensuring compliance with accreditation requirements. At the hospital level, staff reporting directly to the chief of staff or the hospital director are responsible for implementing VHA quality management policy. The Veterans Health Administration's philosophy of quality measurement recognizes the agency's moral imperative to provide America's veterans with care that meets accepted standards. Because the repair of faulty systems is more efficient than the identification of poor performers, VHA has integrated the techniques of total quality into a multifaceted improvement program that also includes the accreditation program and traditional quality assurance activities. VHA monitors its performance by maintaining adverse incident databases, conducting patient satisfaction surveys, contracting for external peer review of 50,000 records per year, and comparing process and outcome rates internally and when possible with external benchmarks. The near-term objectives of VHA include providing medical centers with a quality matrix that will permit local development of quality indicators, construction of a report card for VHA's customers, and implementing the Malcolm W. Baldrige system for quality improvement as the road map for systemwide continuous improvement. Other goals include providing greater access to data, creating a patient-centered database, providing real-time clinical decision support, and expanding the

  12. Validity of a smartphone protractor to measure sagittal parameters in adult spinal deformity.

    PubMed

    Kunkle, William Aaron; Madden, Michael; Potts, Shannon; Fogelson, Jeremy; Hershman, Stuart

    2017-10-01

    Smartphones have become an integral tool in the daily life of health-care professionals (Franko 2011). Their ease of use and wide availability often make smartphones the first tool surgeons use to perform measurements. This technique has been validated for certain orthopedic pathologies (Shaw 2012; Quek 2014; Milanese 2014; Milani 2014), but never to assess sagittal parameters in adult spinal deformity (ASD). This study was designed to assess the validity, reproducibility, precision, and efficiency of using a smartphone protractor application to measure sagittal parameters commonly measured in ASD assessment and surgical planning. This study aimed to (1) determine the validity of smartphone protractor applications, (2) determine the intra- and interobserver reliability of smartphone protractor applications when used to measure sagittal parameters in ASD, (3) determine the efficiency of using a smartphone protractor application to measure sagittal parameters, and (4) elucidate whether a physician's level of experience impacts the reliability or validity of using a smartphone protractor application to measure sagittal parameters in ASD. An experimental validation study was carried out. Thirty standard 36″ standing lateral radiographs were examined. Three separate measurements were performed using a marker and protractor; then at a separate time point, three separate measurements were performed using a smartphone protractor application for all 30 radiographs. The first 10 radiographs were then re-measured two more times, for a total of three measurements from both the smartphone protractor and marker and protractor. The parameters included lumbar lordosis, pelvic incidence, and pelvic tilt. Three raters performed all measurements-a junior level orthopedic resident, a senior level orthopedic resident, and a fellowship-trained spinal deformity surgeon. All data, including the time to perform the measurements, were recorded, and statistical analysis was performed to

  13. Developing Resident-Sensitive Quality Measures: A Model From Pediatric Emergency Medicine.

    PubMed

    Schumacher, Daniel J; Holmboe, Eric S; van der Vleuten, Cees; Busari, Jamiu O; Carraccio, Carol

    2017-12-05

    To begin closing the gap with respect to quality measures available for use among residents, the authors sought to identify and develop resident-sensitive quality measures (RSQMs) for use in the pediatric emergency department (PED) setting. In May 2016, the authors reviewed National Quality Measures Clearinghouse (NQMC) measures to identify resident-sensitive measures. To create additional measures focused on common, acute illnesses (acute asthma exacerbation, bronchiolitis, closed head injury [CHI]) in the PED, the authors used a nominal group technique (NGT) and Delphi process from September to December 2016. To achieve a local focus for developing these measures, all NGT and Delphi participants were from Cincinnati Children's Hospital Medical Center. Delphi participants rated measures developed through the NGT in two areas: importance of measure to quality care and likelihood that measure represents the work of a resident. The review of NQMC measures identified 28 of 183 as being potentially resident-sensitive. The NGT produced 67 measures for asthma, 46 for bronchiolitis, and 48 for CHI. These were used in the first round of the Delphi process. After two rounds, 18 measures for asthma, 21 for bronchiolitis, and 22 for CHI met automatic inclusion criteria. In round three, participants categorized the potential final measures by their top 10 and next 5. This study describes a template for identifying and developing RSQMs that may promote high-quality care delivery during and following training. Next steps should include implementing and seeking validity evidence for the locally developed measures.

  14. A Measurement of the Michel Parameters in Leptonic Decays of the Tau

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ammar, R.; Baringer, P.; Bean, A.

    1997-06-01

    We have measured the spectral shape Michel parameters {rho} and {eta} using leptonic decays of the {tau} , recorded by the CLEO II detector. Assuming e-{mu} universality in the vectorlike couplings, we find {rho}{sub e{mu}}=0.735{plus_minus}0.013{plus_minus}0.008 and {eta}{sub e{mu}}=-0.015{plus_minus}0.061{plus_minus}0.062 , where the first error is statistical and the second systematic. We also present measurements for the parameters for e and {mu} final states separately. {copyright} {ital 1997} {ital The American Physical Society}

  15. [Life quality parameters in prenosologic evaluation of health state in residents of protective measures area near objects of storage and destruction of chemical weapons].

    PubMed

    Filippov, V L; Nechaeva, E N

    2014-01-01

    The article presents results of life quality assessment and subjective evaluation data on health state, used for prenosologic evaluation of health state in residents of protective measures area near objects of storage and destruction of chemical weapons. Considering specific features of residence near potentially dangerous objects, the authors conducted qualitative evaluation of satisfaction with various life facets, with taking into account the objects specificity, established correlation between life quality and self-evaluation of health with factors influencing public health state.

  16. Measuring Quality of Care in Community Mental Health: Validation of Concordant Clinician and Client Quality-of-Care Scales.

    PubMed

    Luther, Lauren; Fukui, Sadaaki; Garabrant, Jennifer M; Rollins, Angela L; Morse, Gary; Henry, Nancy; Shimp, Dawn; Gearhart, Timothy; Salyers, Michelle P

    2018-04-12

    Measuring quality of care can transform care, but few tools exist to measure quality from the client's perspective. The aim of this study was to create concordant clinician and client self-report quality-of-care scales in a sample of community mental health clinicians (n = 189) and clients (n = 469). The client scale had three distinct factors (Person-Centered Care, Negative Staff Interactions, and Inattentive Care), while the clinician scale had two: Person-Centered Care and Discordant Care. Both versions demonstrated adequate internal consistency and validity with measures related to satisfaction and the therapeutic relationship. These measures are promising, brief quality assessment tools.

  17. Distributor- Retailer Interface in Pharmaceutical Supply Chain: Service Quality Measurement Scale.

    PubMed

    Mehralian, Gholamhossein; Babapour, Jafar; Peiravian, Farzad

    2016-01-01

    In the current competitive market, service quality management is the key to the survival and success of businesses. SERVQUAL is a popular service quality measurement scale (SQMS) that has served as a basis for subsequent research on service quality; it has been used for testing different aspects of service quality in a market. The purpose of our study is, therefore, to develop a service quality measurement scale (SQMS) for the distributor-retailer interface of Pharm supply chains (PSC) in Iran. A survey was performed to collect data from pharmacies located in Tehran. A valid and reliable questionnaire delivered to pharmacies, and 400 pharmacies were intended to participate in our survey. Confirmatory factor analysis (CFA) was used to develop an SQMS in this study. Sufficient sampling was undertaken to do CFA. Consistent with other service quality studies, this Res developed an SQMS with five dimensions and 20 items for PSC, and contributes to mangers to regularly measure service quality. This is an initial study to develop a framework for measuring service quality in Iranian PCS. The framework can be used effectively to achieve competitive advantage at the distributor-retailer interface.

  18. Distributor– Retailer Interface in Pharmaceutical Supply Chain: Service Quality Measurement Scale

    PubMed Central

    Mehralian, Gholamhossein; Babapour, Jafar; peiravian, farzad

    2016-01-01

    In the current competitive market, service quality management is the key to the survival and success of businesses. SERVQUAL is a popular service quality measurement scale (SQMS) that has served as a basis for subsequent research on service quality; it has been used for testing different aspects of service quality in a market. The purpose of our study is, therefore, to develop a service quality measurement scale (SQMS) for the distributor–retailer interface of Pharm supply chains (PSC) in Iran. A survey was performed to collect data from pharmacies located in Tehran. A valid and reliable questionnaire delivered to pharmacies, and 400 pharmacies were intended to participate in our survey. Confirmatory factor analysis (CFA) was used to develop an SQMS in this study. Sufficient sampling was undertaken to do CFA. Consistent with other service quality studies, this Res developed an SQMS with five dimensions and 20 items for PSC, and contributes to mangers to regularly measure service quality. This is an initial study to develop a framework for measuring service quality in Iranian PCS. The framework can be used effectively to achieve competitive advantage at the distributor–retailer interface. PMID:28243297

  19. Investigation of measureable parameters that correlate with automatic target recognition performance in synthetic aperture sonar

    NASA Astrophysics Data System (ADS)

    Gazagnaire, Julia; Cobb, J. T.; Isaacs, Jason

    2015-05-01

    There is a desire in the Mine Counter Measure community to develop a systematic method to predict and/or estimate the performance of Automatic Target Recognition (ATR) algorithms that are detecting and classifying mine-like objects within sonar data. Ideally, parameters exist that can be measured directly from the sonar data that correlate with ATR performance. In this effort, two metrics were analyzed for their predictive potential using high frequency synthetic aperture sonar (SAS) images. The first parameter is a measure of contrast. It is essentially the variance in pixel intensity over a fixed partition of relatively small size. An analysis was performed to determine the optimum block size for this contrast calculation. These blocks were then overlapped in the horizontal and vertical direction over the entire image. The second parameter is the one-dimensional K-shape parameter. The K-distribution is commonly used to describe sonar backscatter return from range cells that contain a finite number of scatterers. An Ada-Boosted Decision Tree classifier was used to calculate the probability of classification (Pc) and false alarm rate (FAR) for several types of targets in SAS images from three different data sets. ROC curves as a function of the measured parameters were generated and the correlation between the measured parameters in the vicinity of each of the contacts and the ATR performance was investigated. The contrast and K-shape parameters were considered separately. Additionally, the contrast and K-shape parameter were associated with background texture types using previously labeled high frequency SAS images.

  20. DockQ: A Quality Measure for Protein-Protein Docking Models

    PubMed Central

    Basu, Sankar

    2016-01-01

    The state-of-the-art to assess the structural quality of docking models is currently based on three related yet independent quality measures: Fnat, LRMS, and iRMS as proposed and standardized by CAPRI. These quality measures quantify different aspects of the quality of a particular docking model and need to be viewed together to reveal the true quality, e.g. a model with relatively poor LRMS (>10Å) might still qualify as 'acceptable' with a descent Fnat (>0.50) and iRMS (<3.0Å). This is also the reason why the so called CAPRI criteria for assessing the quality of docking models is defined by applying various ad-hoc cutoffs on these measures to classify a docking model into the four classes: Incorrect, Acceptable, Medium, or High quality. This classification has been useful in CAPRI, but since models are grouped in only four bins it is also rather limiting, making it difficult to rank models, correlate with scoring functions or use it as target function in machine learning algorithms. Here, we present DockQ, a continuous protein-protein docking model quality measure derived by combining Fnat, LRMS, and iRMS to a single score in the range [0, 1] that can be used to assess the quality of protein docking models. By using DockQ on CAPRI models it is possible to almost completely reproduce the original CAPRI classification into Incorrect, Acceptable, Medium and High quality. An average PPV of 94% at 90% Recall demonstrating that there is no need to apply predefined ad-hoc cutoffs to classify docking models. Since DockQ recapitulates the CAPRI classification almost perfectly, it can be viewed as a higher resolution version of the CAPRI classification, making it possible to estimate model quality in a more quantitative way using Z-scores or sum of top ranked models, which has been so valuable for the CASP community. The possibility to directly correlate a quality measure to a scoring function has been crucial for the development of scoring functions for protein structure

  1. WSN based indoor air quality monitoring in classrooms

    NASA Astrophysics Data System (ADS)

    Wang, S. K.; Chew, S. P.; Jusoh, M. T.; Khairunissa, A.; Leong, K. Y.; Azid, A. A.

    2017-03-01

    Indoor air quality monitoring is essential as the human health is directly affected by indoor air quality. This paper presents the investigations of the impact of undergraduate students' concentration during lecture due to the indoor air quality in classroom. Three environmental parameters such as temperature, relative humidity and concentration of carbon dioxide are measured using wireless sensor network based air quality monitoring system. This simple yet reliable system is incorporated with DHT-11 and MG-811 sensors. Two classrooms were selected to install the monitoring system. The level of indoor air quality were measured and students' concentration was assessed using intelligent test during normal lecturing section. The test showed significant correlation between the collected environmental parameters and the students' level of performances in their study.

  2. Mobile data buoy system. [water quality measurements in watersheds and Mobile Bay, Alabama

    NASA Technical Reports Server (NTRS)

    Morton, R. A.

    1975-01-01

    The Mobile Data Buoy System was conceived to serve the users requirement for obtaining water quality parameters from two separate watershed systems. In view of the cost constraints of the ERTS program it was obvious that the network of 10 sampling stations required could not be of the fixed installation type; therefore, it was decided to go to a system of battery powered buoys of a size that could be used in one watershed system for a period of time and then moved to another by use of a relatively small 6.7 m (22 foot) boat. The basic idea of the water quality measurement program was to establish the water quality pattern of change from the headwaters of the watersheds to and through the Mobile Bay. This would allow the investigator to develop a good picture of the state's major water resources and the pressures from pollution that are being imposed. At this point in deployment of this mobile system of buoys, it is too early to put a quantitative value on the system, however it appears less expensive than known fixed installations as to first cost. It has a basic advantage in that it can be moved, at very little expense, to alternate sites where it is desired to obtain water quality data. It is to be noted this buoy system which covers a 80 Km (50 mile) stretch of the Black Warrior River and then skips down 483 Km (300 miles) to Mobile Bay for the next measurements would not be feasible unless there is a satellite to collect and relay the data.

  3. [Weight parameters of water quality impact and risk grade determination of water environmental sensitive spots in Jiashan].

    PubMed

    Xie, Rong-Rong; Pang, Yong; Zhang, Qian; Chen, Ke; Sun, Ming-Yuan

    2012-07-01

    For the safety of the water environment in Jiashan county in Zhejiang Province, one-dimensional hydrodynamic and water quality models are established based on three large-scale monitoring of hydrology and water quality in Jiashan county, three water environmental sensitive spots including Hongqitang dam Chijia hydrological station and Luxie pond are selected to investigate weight parameters of water quality impact and risk grade determination. Results indicate as follows (1) Internal pollution impact in Jiashan areas was greater than the external, the average weight parameters of internal chemical oxygen demand (COD) pollution is 55.3%, internal ammonia nitrogen (NH(4+)-N) is 67.4%, internal total phosphor (TP) is 63.1%. Non-point pollution impact in Jiashan areas was greater than point pollution impact, the average weight parameters of non-point COD pollutions is 53.7%, non-point NH(4+)-N is 65.9%, non-point TP is 57.8%. (2) The risk of Hongqitang dam and Chijia hydrological station are in the middle risk. The risk of Luxie pond is also in the middle risk in August, and in April and December the risk of Luxie pond is low. The strategic decision will be suggested to guarantee water environment security and social and economic security in the study.

  4. The role of quality measurement in a competitive marketplace.

    PubMed

    Epstein, A M

    1996-01-01

    Quality measurement is not a new idea. However, in recent years, several new trends have gained prominence: greater interest in publicly reported information on quality of care, access to care, and patient satisfaction; an increased focus on health plans and integrated systems of care rather than on institutional providers and practitioners as the unit of observation; wide adoption of the techniques of continuous quality improvement within the health care sector; increased use of clinical practice guidelines to improve care for a broad range of medical conditions; incorporation of computer technology into the clinical setting; and greater appreciation for health outcomes as a measure of quality of care. This chapter first reviews the changes in the medical landscape that have seeded these trends and the distinction between quality assurance and quality improvement. It then focuses on public policy concerns, in particular on the emergence of publicly disseminated information about quality of care, now often called "quality report cards." The major prototypes of these reports developed to date, the responses to quality reporting by different members of the delivery system, and the major criticisms of this approach are reviewed. The chapter concludes by predicting probable developments and the strategies most likely to move health care forward in a productive direction.

  5. Quantitative MRI and strength measurements in the assessment of muscle quality in Duchenne muscular dystrophy.

    PubMed

    Wokke, B H; van den Bergen, J C; Versluis, M J; Niks, E H; Milles, J; Webb, A G; van Zwet, E W; Aartsma-Rus, A; Verschuuren, J J; Kan, H E

    2014-05-01

    The purpose of this study was to assess leg muscle quality and give a detailed description of leg muscle involvement in a series of Duchenne muscular dystrophy patients using quantitative MRI and strength measurements. Fatty infiltration, as well as total and contractile (not fatty infiltrated) cross sectional areas of various leg muscles were determined in 16 Duchenne patients and 11 controls (aged 8-15). To determine specific muscle strength, four leg muscle groups (quadriceps femoris, hamstrings, anterior tibialis and triceps surae) were measured and related to the amount of contractile tissue. In patients, the quadriceps femoris showed decreased total and contractile cross sectional area, attributable to muscle atrophy. The total, but not the contractile, cross sectional area of the triceps surae was increased in patients, corresponding to hypertrophy. Specific strength decreased in all four muscle groups of Duchenne patients, indicating reduced muscle quality. This suggests that muscle hypertrophy and fatty infiltration are two distinct pathological processes, differing between muscle groups. Additionally, the quality of remaining muscle fibers is severely reduced in the legs of Duchenne patients. The combination of quantitative MRI and quantitative muscle testing could be a valuable outcome parameter in longitudinal studies and in the follow-up of therapeutic effects. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. The Association between Parameters of Malnutrition and Diagnostic Measures of Sarcopenia in Geriatric Outpatients

    PubMed Central

    Reijnierse, Esmee M.; Trappenburg, Marijke C.; Leter, Morena J.; Blauw, Gerard Jan; de van der Schueren, Marian A. E.; Meskers, Carel G. M.; Maier, Andrea B.

    2015-01-01

    Objectives Diagnostic criteria for sarcopenia include measures of muscle mass, muscle strength and physical performance. Consensus on the definition of sarcopenia has not been reached yet. To improve insight into the most clinically valid definition of sarcopenia, this study aimed to compare the association between parameters of malnutrition, as a risk factor in sarcopenia, and diagnostic measures of sarcopenia in geriatric outpatients. Material and Methods This study is based on data from a cross-sectional study conducted in a geriatric outpatient clinic including 185 geriatric outpatients (mean age 82 years). Parameters of malnutrition included risk of malnutrition (assessed by the Short Nutritional Assessment Questionnaire), loss of appetite, unintentional weight loss and underweight (body mass index <22 kg/m2). Diagnostic measures of sarcopenia included relative muscle mass (lean mass and appendicular lean mass [ALM] as percentages), absolute muscle mass (total lean mass and ALM/height2), handgrip strength and walking speed. All diagnostic measures of sarcopenia were standardized. Associations between parameters of malnutrition (independent variables) and diagnostic measures of sarcopenia (dependent variables) were analysed using multivariate linear regression models adjusted for age, body mass, fat mass and height in separate models. Results None of the parameters of malnutrition was consistently associated with diagnostic measures of sarcopenia. The strongest associations were found for both relative and absolute muscle mass; less stronger associations were found for muscle strength and physical performance. Underweight (p = <0.001) and unintentional weight loss (p = 0.031) were most strongly associated with higher lean mass percentage after adjusting for age. Loss of appetite (p = 0.003) and underweight (p = 0.021) were most strongly associated with lower total lean mass after adjusting for age and fat mass. Conclusion Parameters of malnutrition relate

  7. Colour Measurements and Modeling

    NASA Astrophysics Data System (ADS)

    Jha, Shyam N.

    The most common property to measure quality of any material is its appearance. Appearance includes colour, shape, size and surface conditions. The analysis of colour is especially an important consideration when determining the efficacy of variety of postharvest treatments. Consumers can easily be influenced by preconceived ideas of how a particular fruit or vegetable or a processed food should appear, and marketers often attempt to improve upon what nature has painted. Recently colour measurements have also been used as quality parameters and indicator of some inner constituents of the material. In spite of the significance of colour in food industries, many continue to analyze it inadequately. This chapter deals with theory of colour, colour scales and its measurement, sampling techniques, and modeling of colour values for correlating them with some internal quality parameters of selected fruits.

  8. The relationship of geophysical measurements to engineering and construction parameters in the Straight Creek Tunnel pilot bore, Colorado

    USGS Publications Warehouse

    Scott, J.H.; Lee, F.T.; Carroll, R.D.; Robinson, C.S.

    1968-01-01

    Seismic-refraction and electrical-resistivity measurements made along the walls of the Straight Creek Tunnel pilot bore indicate that both a low-velocity and a high-resistivity layer exist in the disturbed rock surrounding the excavation. Seismic measurements were analyzed to obtain the thickness and seismic velocity of rock in the low-velocity layer, the velocity of rock behind the layer and the amplitude of seismic energy received at the detectors. Electrical-resistivity measurements were analyzed to obtain the thickness and electrical resistivity of the high-resistivity layer and the resistivity of rock behind the layer. The electrical resistivity and the seismic velocity of rock at depth, the thickness of rock in the low-velocity layer, and the relative amplitude of seismic energy were correlated against the following parameters, all of which are important in tunnel construction: height of the tension arch, stable vertical rock load, rock quality, rate of construction and cost per foot, percentage of lagging and blocking, set spacing, and type and amount of steel support required, The correlations were statistically meaningful, having correlation coefficients ranging in absolute value from about 0??7 to nearly 1??0. This finding suggests the possibility of predicting parameters of interest in tunnel construction from geophysical measurements made in feeler holes drilled ahead of a working face. Predictions might be based on correlations established either during the early stages of construction or from geophysical surveys in other tunnels of similar design in similar geologic environments. ?? 1968.

  9. Measuring quality progress

    NASA Astrophysics Data System (ADS)

    Lambert, Larry D.

    The study by the American Productivity & Quality Center (APQC) was commissioned by Loral Space Information Systems, Inc. and the National Aeronautics and Space Administration (NASA) to evaluate internal assessment systems. APQC benchmarked approaches to the internal assessment of quality management systems in three phases. The first phase included work conducted for the International Benchmarking Clearinghouse (IBC) and consisted of an in-depth analysis of the 1991 Malcolm Baldrige National Quality Award criteria. The second phase was also performed for the IBC and compared the 1991 award criteria among the following quality awards: Deming Prize, Malcolm Baldrige National Quality Award, The President's Award for Quality and Productivity Improvement, The NASA Excellence Award (The George M. Lowe Trophy) for Quality and Productivity Improvement and the Shigeo Shingo Award for Excellence in Manufacturing. The third phase compared the internal implementation approaches of 23 companies selected from American industry for their recognized, formal assessment systems.

  10. Measuring quality progress

    NASA Technical Reports Server (NTRS)

    Lambert, Larry D.

    1992-01-01

    The study by the American Productivity & Quality Center (APQC) was commissioned by Loral Space Information Systems, Inc. and the National Aeronautics and Space Administration (NASA) to evaluate internal assessment systems. APQC benchmarked approaches to the internal assessment of quality management systems in three phases. The first phase included work conducted for the International Benchmarking Clearinghouse (IBC) and consisted of an in-depth analysis of the 1991 Malcolm Baldrige National Quality Award criteria. The second phase was also performed for the IBC and compared the 1991 award criteria among the following quality awards: Deming Prize, Malcolm Baldrige National Quality Award, The President's Award for Quality and Productivity Improvement, The NASA Excellence Award (The George M. Lowe Trophy) for Quality and Productivity Improvement and the Shigeo Shingo Award for Excellence in Manufacturing. The third phase compared the internal implementation approaches of 23 companies selected from American industry for their recognized, formal assessment systems.

  11. Correction of stream quality trends for the effects of laboratory measurement bias

    USGS Publications Warehouse

    Alexander, Richard B.; Smith, Richard A.; Schwarz, Gregory E.

    1993-01-01

    We present a statistical model relating measurements of water quality to associated errors in laboratory methods. Estimation of the model allows us to correct trends in water quality for long-term and short-term variations in laboratory measurement errors. An illustration of the bias correction method for a large national set of stream water quality and quality assurance data shows that reductions in the bias of estimates of water quality trend slopes are achieved at the expense of increases in the variance of these estimates. Slight improvements occur in the precision of estimates of trend in bias by using correlative information on bias and water quality to estimate random variations in measurement bias. The results of this investigation stress the need for reliable, long-term quality assurance data and efficient statistical methods to assess the effects of measurement errors on the detection of water quality trends.

  12. Sampling errors in the measurement of rain and hail parameters

    NASA Technical Reports Server (NTRS)

    Gertzman, H. S.; Atlas, D.

    1977-01-01

    Attention is given to a general derivation of the fractional standard deviation (FSD) of any integrated property X such that X(D) = cD to the n. This work extends that of Joss and Waldvogel (1969). The equation is applicable to measuring integrated properties of cloud, rain or hail populations (such as water content, precipitation rate, kinetic energy, or radar reflectivity) which are subject to statistical sampling errors due to the Poisson distributed fluctuations of particles sampled in each particle size interval and the weighted sum of the associated variances in proportion to their contribution to the integral parameter to be measured. Universal curves are presented which are applicable to the exponential size distribution permitting FSD estimation of any parameters from n = 0 to n = 6. The equations and curves also permit corrections for finite upper limits in the size spectrum and a realistic fall speed law.

  13. Health-related quality of life measurement in oncology: advances and opportunities.

    PubMed

    Cella, David; Stone, Arthur A

    2015-01-01

    The concept of health-related quality of life has a long history in the field of oncology treatment and research. We present a brief history of how the concept has evolved in oncology and the sentinel events in that process. We then focus on advances in measurement science as applied to health-related quality of life measures and argue that a compelling new set of measurement tools is now available, including brief, generic measures with good psychometric qualities (exemplified by the new PROMIS measures and the possibility of a common metric spanning all diseases). The last section of the paper turns to emerging opportunities for these measures, including in clinical trials, healthcare reform, and regulatory deliberations. Our conclusion is that health-related quality of life is more important today than it has ever been, and that the time has come for an even wider adoption of the new measures. PsycINFO Database Record (c) 2015 APA, all rights reserved.

  14. Measuring Environmental Quality in the Southern Appalachian Mountains

    Treesearch

    Linwood Pendleton; Brent Sohngen; Robert Mendelsohn; Thomas Holmes

    1998-01-01

    This study presents a method for valuing recreational environmental quality in the forests of the southeastern United States. The paper offers a method for choosing, measuring, and valuing forest attributes. Surveys and popular recreation literature are used to identify forest attributes that contribute to recreational quality. Standard ecological techniques are...

  15. Measuring quality of life in cleft lip and palate patients: currently available patient-reported outcomes measures.

    PubMed

    Eckstein, Donna A; Wu, Rebecca L; Akinbiyi, Takintope; Silver, Lester; Taub, Peter J

    2011-11-01

    Patient-reported outcomes in cleft lip and palate treatment are critical for patient care. Traditional surgical outcomes focused on objective measures, such as photographs, anatomic measurements, morbidity, and mortality. Although these remain important, they leave many questions unanswered. Surveys that include aesthetics, speech, functionality, self-image, and quality of life provide more thorough outcomes assessment. It is vital that reliable, valid, and comprehensive questionnaires are available to craniofacial surgeons. The authors performed a literature review to identify questionnaires validated in cleft lip and palate patients. Qualifying instruments were assessed for adherence to guidelines for development and validation by the scientific advisory committee and for content. The authors identified 44 measures used in cleft lip and palate studies. After 15 ad hoc questionnaires, eight generic instruments, 11 psychiatric instruments, and one non-English language questionnaire were excluded, nine measures remained. Of these, four were never validated in the cleft population. Analysis revealed one craniofacial-specific measure (Youth Quality of Life-Facial Differences), two voice-related measures (Patient Voice-Related Quality of Life and Cleft Audit Protocol for Speech-Augmented), and two oral health-related measures (Child Oral Health Impact Profile and Child Oral Health Quality of Life). The Youth Quality of Life-Facial Differences, Child Oral Health Impact Profile, and Child Oral Health Quality of Life questionnaires were sufficiently validated. None was created specifically for clefts, resulting in content limitations. There is a lack of comprehensive, valid, and reliable questionnaires for cleft lip and palate surgery. For thorough assessment of satisfaction, further research to develop and validate cleft lip and palate surgery-specific instruments is needed.

  16. Real-Time Aerodynamic Parameter Estimation without Air Flow Angle Measurements

    NASA Technical Reports Server (NTRS)

    Morelli, Eugene A.

    2010-01-01

    A technique for estimating aerodynamic parameters in real time from flight data without air flow angle measurements is described and demonstrated. The method is applied to simulated F-16 data, and to flight data from a subscale jet transport aircraft. Modeling results obtained with the new approach using flight data without air flow angle measurements were compared to modeling results computed conventionally using flight data that included air flow angle measurements. Comparisons demonstrated that the new technique can provide accurate aerodynamic modeling results without air flow angle measurements, which are often difficult and expensive to obtain. Implications for efficient flight testing and flight safety are discussed.

  17. A system for automated noise parameter measurements on MR preamplifiers and application to high B(0) fields.

    PubMed

    Lagore, Russell L; Roberts, Brodi Roduta; Possanzini, Cecilia; Saylor, Charles; Fallone, B Gino; De Zanche, Nicola

    2014-08-01

    A noise figure and noise parameter measurement system was developed that consists of a combination spectrum and network analyzer, preamplifier, programmable power supply, noise source, tuning board, and desktop computer. The system uses the Y-factor method for noise figure calculation and allows calibrations to correct for a decrease in excess noise ratio between the noise source and device under test, second stage (system) noise, ambient temperature variations, and available gain of the device under test. Noise parameters are extracted by performing noise figure measurements at several source impedance values obtained by adjusting an electronically controlled tuner. Results for several amplifiers at 128 MHz and 200 MHz agree with independent measurements and with the corresponding datasheets. With some modifications, the system was also used to characterize the noise figure of MRI preamplifiers in strong static magnetic fields up to 9.4 T. In most amplifiers tested the gain was found to be reduced by the magnetic field, while the noise figure increased. These changes are detrimental to signal quality (SNR) and are dependent on the electron mobility and design of the amplifier's semiconductor devices. Consequently, gallium arsenide (GaAs) field-effect transistors are most sensitive to magnetic fields due to their high electron mobility and long, narrow channel, while silicon-germanium (SiGe) bipolar transistor amplifiers are largely immune due to their very thin base. Copyright © 2014 John Wiley & Sons, Ltd.

  18. Deriving aerosol parameters from in-situ spectrometer measurements for validation of remote sensing products

    NASA Astrophysics Data System (ADS)

    Riedel, Sebastian; Janas, Joanna; Gege, Peter; Oppelt, Natascha

    2017-10-01

    Uncertainties of aerosol parameters are the limiting factor for atmospheric correction over inland and coastal waters. For validating remote sensing products from these optically complex and spatially inhomogeneous waters the spatial resolution of automated sun photometer networks like AERONET is too coarse and additional measurements on the test site are required. We have developed a method which allows the derivation of aerosol parameters from measurements with any spectrometer with suitable spectral range and resolution. This method uses a pair of downwelling irradiance and sky radiance measurements for the extraction of the turbidity coefficient and aerosol Ångström exponent. The data can be acquired fast and reliable at almost any place during a wide range of weather conditions. A comparison to aerosol parameters measured with a Cimel sun photometer provided by AERONET shows a reasonable agreement for the Ångström exponent. The turbidity coefficient did not agree well with AERONET values due to fit ambiguities, indicating that future research should focus on methods to handle parameter correlations within the underlying model.

  19. Differential recovery of water quality parameters eight years after severe wildfire and salvage logging in Alberta's southern Rocky Mountains

    NASA Astrophysics Data System (ADS)

    Silins, U.; Bladon, K. D.; Stone, M.; Emelko, M. B.; Collins, A.; Boon, S.; Williams, C.; Wagner, M. J.; Martens, A. M.; Anderson, A.

    2012-12-01

    Broad regions of western North America rely on water supplies that originate from forested regions of the Rocky Mountain cordillera where landuse pressures, and stresses including changing natural disturbance regimes associated with shifting climates has been impacting critical source water supplies from this region. Increases in magnitude and severity of wildfires along with impacts on downstream water supplies has been observed along the length of the North American Rocky Mountain chain, however, the longevity of these impacts (including impacts to important water quality parameters) remain highly uncertain because processes regulating recovery from such disturbances can span a range of timescales from a few years to decades depending on both the hydro-climatic regime, and which water quality parameters are important. Studies document such long-term changes are few. The Southern Rockies Watershed Project (SRWP) was established to document the magnitude and recovery from the severe 2003 Lost Creek wildfire in the Crowsnest Pass region of southwest Alberta, Canada. Hydrology, water quality (physical & chemical) have been studies in 9 instrumented catchments (4-14 km2) encompassing burned, burned and salvage logged, prescribed burned, and unburned (reference) conditions since late winter 2004. While most important water quality parameters were strongly elevated in burned and burned-salvage logged catchments after the fire, strongly differential rates of recovery were observed for contaminant concentration, export, and yield across a range of water quality parameters (2004-2011). For example, while various nitrogen (N) species (total nitrogen, dissolved nitrogen, NO3-, NH4+) showed 2-7 fold increases in concentration the first 1-2 years after the wildfire, N recovered back to baseline concentrations 4-5 years after the wildfire. In contrast, eight full years after the wildfire (2011), no recovery of sediment or phosphorus (P) production (soluble reactive, total

  20. Measurement properties of adult quality-of-life measurement instruments for eczema: a systematic review.

    PubMed

    Heinl, D; Prinsen, C A C; Deckert, S; Chalmers, J R; Drucker, A M; Ofenloch, R; Humphreys, R; Sach, T; Chamlin, S L; Schmitt, J; Apfelbacher, C

    2016-03-01

    The Harmonising Outcome Measures for Eczema (HOME) initiative has identified quality of life (QoL) as a core outcome domain to be evaluated in every eczema trial. It is unclear which of the existing QoL instruments is most appropriate for this domain. Thus, the aim of this review was to systematically assess the measurement properties of existing measurement instruments developed and/or validated for the measurement of QoL in adult eczema. We conducted a systematic literature search in PubMed and Embase identifying studies on measurement properties of adult eczema QoL instruments. For all eligible studies, we assessed the adequacy of the measurement properties and the methodological quality with the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist. A best evidence synthesis summarizing findings from different studies was the basis to assign four degrees of recommendation (A-D). A total of 15 articles reporting on 17 instruments were included. No instrument fulfilled the criteria for category A. Six instruments were placed in category B, meaning that they have the potential to be recommended depending on the results of further validation studies. Three instruments had poor adequacy in at least one required adequacy criterion and were therefore put in category C. The remaining eight instruments were minimally validated and were thus placed in category D. Currently, no QoL instrument can be recommended for use in adult eczema. The Quality of Life Index for Atopic Dermatitis (QoLIAD) and the Dermatology Life Quality Index (DLQI) are recommended for further validation research. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Useful measures and models for analytical quality management in medical laboratories.

    PubMed

    Westgard, James O

    2016-02-01

    The 2014 Milan Conference "Defining analytical performance goals 15 years after the Stockholm Conference" initiated a new discussion of issues concerning goals for precision, trueness or bias, total analytical error (TAE), and measurement uncertainty (MU). Goal-setting models are critical for analytical quality management, along with error models, quality-assessment models, quality-planning models, as well as comprehensive models for quality management systems. There are also critical underlying issues, such as an emphasis on MU to the possible exclusion of TAE and a corresponding preference for separate precision and bias goals instead of a combined total error goal. This opinion recommends careful consideration of the differences in the concepts of accuracy and traceability and the appropriateness of different measures, particularly TAE as a measure of accuracy and MU as a measure of traceability. TAE is essential to manage quality within a medical laboratory and MU and trueness are essential to achieve comparability of results across laboratories. With this perspective, laboratory scientists can better understand the many measures and models needed for analytical quality management and assess their usefulness for practical applications in medical laboratories.

  2. Optical measurement of medical aerosol media parameters

    NASA Astrophysics Data System (ADS)

    Sharkany, Josif P.; Zhytov, Nikolay B.; Sichka, Mikhail J.; Lemko, Ivan S.; Pintye, Josif L.; Chonka, Yaroslav V.

    2000-07-01

    The problem of aerosol media parameters measurements are presented in the work and these media are used for the treatment of the patients with bronchial asthma moreover we show the results of the development and the concentration and dispersity of the particles for the long-term monitoring under such conditions when the aggressive surroundings are available. The system for concentration measurements is developed, which consists of two identical photometers permitting to carry out the measurements of the transmission changes and the light dispersion depending on the concentration of the particles. The given system permits to take into account the error, connected with the deposition of the salt particles on the optical windows and the mirrors in the course of the long-term monitoring. For the controlling of the dispersity of the aggressive media aerosols the optical system is developed and used for the non-stop analysis of the Fure-spectra of the aerosols which deposit on the lavsan film. The registration of the information is performed with the help of the rule of the photoreceivers or CCD-chamber which are located in the Fure- plane. With the help of the developed optical system the measurements of the concentration and dispersity of the rock-salt aerosols were made in the medical mines of Solotvino (Ukraine) and in the artificial chambers of the aerosol therapy.

  3. Natural organic matter (NOM) adsorption to multi-walled carbon nanotubes: effect of NOM characteristics and water quality parameters.

    PubMed

    Hyung, Hoon; Kim, Jae-Hong

    2008-06-15

    The effect of natural organic matter (NOM) characteristics and water quality parameters on NOM adsorption to multiwalled carbon nanotubes (MWNT) was investigated. Isotherm experiment results were fitted well with a modified Freundlich isotherm model that took into account the heterogeneous nature of NOM. The preferential adsorption of the higher molecular weight fraction of NOM was observed by size exclusion chromatographic analysis. Experiments performed with various NOM samples suggested that the degree of NOM adsorption varied greatly depending on the type of NOM and was proportional to the aromatic carbon content of NOM. The NOM adsorption to MWNT was also dependent on water quality parameters: adsorption increased as pH decreased and ionic strength increased. As a result of NOM adsorption to MWNT, a fraction of MWNT formed a stable suspension in water and the concentration of MWNT suspension depended on the amount of NOM adsorbed per unit mass of MWNT. The amount of MWNT suspended in water was also affected by ionic strength and pH. The findings in this study suggested that the fate and transport of MWNT in natural systems would be largely influenced by NOM characteristics and water quality parameters.

  4. Linking Quality and Spending to Measure Value for People with Serious Illness.

    PubMed

    Ryan, Andrew M; Rodgers, Phillip E

    2018-03-01

    Healthcare payment is rapidly evolving to reward value by measuring and paying for quality and spending performance. Rewarding value for the care of seriously ill patients presents unique challenges. To evaluate the state of current efforts to measure and reward value for the care of seriously ill patients. We performed a PubMed search of articles related to (1) measures of spending for people with serious illness and (2) linking spending and quality measures and rewarding performance for the care of people with serious illness. We limited our search to U.S.-based studies published in English between January 1, 1960, and March 31, 2017. We supplemented this search by identifying public programs and other known initiatives that linked quality and spending for the seriously ill and extracted key program elements. Our search related to linking spending and quality measures and rewarding performance for the care of people with serious illness yielded 277 articles. We identified three current public programs that currently link measures of quality and spending-or are likely to within the next few years-the Oncology Care Model; the Comprehensive End-Stage Renal Disease Model; and Home Health Value-Based Purchasing. Models that link quality and spending consist of four core components: (1) measuring quality, (2) measuring spending, (3) the payment adjustment model, and (4) the linking/incentive model. We found that current efforts to reward value for seriously ill patients are targeted for specific patient populations, do not broadly encourage the use of palliative care, and have not closely aligned quality and spending measures related to palliative care. We develop recommendations for policymakers and stakeholders about how measures of spending and quality can be balanced in value-based payment programs.

  5. Linking Quality and Spending to Measure Value for People with Serious Illness

    PubMed Central

    Rodgers, Phillip E.

    2018-01-01

    Abstract Background: Healthcare payment is rapidly evolving to reward value by measuring and paying for quality and spending performance. Rewarding value for the care of seriously ill patients presents unique challenges. Objective: To evaluate the state of current efforts to measure and reward value for the care of seriously ill patients. Design: We performed a PubMed search of articles related to (1) measures of spending for people with serious illness and (2) linking spending and quality measures and rewarding performance for the care of people with serious illness. We limited our search to U.S.-based studies published in English between January 1, 1960, and March 31, 2017. We supplemented this search by identifying public programs and other known initiatives that linked quality and spending for the seriously ill and extracted key program elements. Results: Our search related to linking spending and quality measures and rewarding performance for the care of people with serious illness yielded 277 articles. We identified three current public programs that currently link measures of quality and spending—or are likely to within the next few years—the Oncology Care Model; the Comprehensive End-Stage Renal Disease Model; and Home Health Value-Based Purchasing. Models that link quality and spending consist of four core components: (1) measuring quality, (2) measuring spending, (3) the payment adjustment model, and (4) the linking/incentive model. We found that current efforts to reward value for seriously ill patients are targeted for specific patient populations, do not broadly encourage the use of palliative care, and have not closely aligned quality and spending measures related to palliative care. Conclusions: We develop recommendations for policymakers and stakeholders about how measures of spending and quality can be balanced in value-based payment programs. PMID:29091529

  6. Precision measurements of thermodynamic parameters of heavy alkali metals

    NASA Astrophysics Data System (ADS)

    Blagonravov, L. A.; Modenov, A. A.

    2017-11-01

    On the temperature dependences of a number of one-component liquids, regions of anomalous behavior in the form of kinks and also in the form of limited areas of forced growth have been previously observed (LA Blagonravov, LA Orlov, et al., TVT 2000, vol. 38, No. 4, p.566-572). However, the interpretation of these anomalies is complicated by the small magnitude of the effects themselves (the magnitude of the observed effect was 5%, a random error of 2-3%). An increase in the accuracy of measurements is required for a more confident determination of the detailed shape of the anomalies. In the proposed work, thermodynamic parameters are studied using a technique that uses the elastic-thermal effect. The adiabatic thermal coefficient of pressure (a.t.p.c.) is measured: χ = (1/T)(∂T/∂p)S. An installation in which the pressure change is carried out in a periodic mode is used for measurements. The software allows simultaneous averaging of the values of the amplitude of pressure oscillations and the amplitude of temperature response oscillations with the subsequent determination of their ratio. The facility uses an advanced pressure modulator, which allows creating pressure oscillations of the shape close to sinusoidal (the value of the second harmonic is not more than 10%) and a precision SR-810 nanovoltmeter with a synchronous digital detector. The currently used technique provides an acceptable measurement accuracy (error in the region of 0.5-1%). However, to further increase the accuracy, it was decided to make changes in the measuring path. Namely, by developing and applying a scheme of a precision low-noise preamplifier based on the instrument amplifier INA333, a circuit allowing simultaneous measurement of not only the two above parameters but also the current temperature of the sample (to exclude the effect of temperature drift.) Preliminary results of measurements of the temperature dependence of the a.t.p.c. of liquid cesium in the temperature range up to

  7. Biometric parameters of the bream (Abramis brama) as indicators for long-term changes in fish health and environmental quality--data from the German ESB.

    PubMed

    Teubner, Diana; Paulus, Martin; Veith, Michael; Klein, Roland

    2015-02-01

    Piscifaunal health depends upon the state and quality of the aquatic environment. Variations in physical condition of fish may therefore be attributed to changes in environmental quality. Based on time series of up to 20 years of biometric data of bream from multiple sampling sites of the German environmental specimen bank (ESB), this study assessed whether changes in biometric parameters are able to indicate long-term alterations in fish health and environmental quality. Evaluated biometric parameters of fish health comprised length and weight of individuals of a defined age class, the condition factor, lipid content and hepatosomatic index (HSI). Although there are negative trends of the HSI, the overall development of health parameters can be interpreted as positive. This seems to suggest that health parameters conclusively mirror the long-term improvement of water quality in the selected rivers. However, the applicability of the condition factor as well as lipid content as indicators for fish health remained subject to restrictions. Altogether, the results from the ESB confirmed the high value of biometric parameters for monitoring of long-term changes in state and quality of aquatic ecosystems.

  8. Estimation of both optical and nonoptical surface water quality parameters using Landsat 8 OLI imagery and statistical techniques

    NASA Astrophysics Data System (ADS)

    Sharaf El Din, Essam; Zhang, Yun

    2017-10-01

    Traditional surface water quality assessment is costly, labor intensive, and time consuming; however, remote sensing has the potential to assess surface water quality because of its spatiotemporal consistency. Therefore, estimating concentrations of surface water quality parameters (SWQPs) from satellite imagery is essential. Remote sensing estimation of nonoptical SWQPs, such as chemical oxygen demand (COD), biochemical oxygen demand (BOD), and dissolved oxygen (DO), has not yet been performed because they are less likely to affect signals measured by satellite sensors. However, concentrations of nonoptical variables may be correlated with optical variables, such as turbidity and total suspended sediments, which do affect the reflected radiation. In this context, an indirect relationship between satellite multispectral data and COD, BOD, and DO can be assumed. Therefore, this research attempts to develop an integrated Landsat 8 band ratios and stepwise regression to estimate concentrations of both optical and nonoptical SWQPs. Compared with previous studies, a significant correlation between Landsat 8 surface reflectance and concentrations of SWQPs was achieved and the obtained coefficient of determination (R2)>0.85. These findings demonstrated the possibility of using our technique to develop models to estimate concentrations of SWQPs and to generate spatiotemporal maps of SWQPs from Landsat 8 imagery.

  9. Measurement of steady-state minority-carrier transport parameters in heavily doped n-type silicon

    NASA Technical Reports Server (NTRS)

    Del Alamo, Jesus A.; Swanson, Richard M.

    1987-01-01

    The relevant hole transport and recombination parameters in heavily doped n-type silicon under steady state are the hole diffusion length and the product of the hole diffusion coefficient times the hole equilibrium concentration. These parameters have measured in phosphorus-doped silicon grown by epitaxy throughout nearly two orders of magnitude of doping level. Both parameters are found to be strong functions of donor concentration. The equilibrium hole concentration can be deduced from the measurement. A rigid shrinkage of the forbidden gap appears as the dominant heavy doping mechanism in phosphorus-doped silicon.

  10. SU-F-P-64: The Impact of Plan Complexity Parameters On the Plan Quality and Deliverability of Volumetric Modulated Arc Therapy with Canonical Correlation Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jin, X; Yi, J; Xie, C

    Purpose: To evaluate the impact of complexity indices on the plan quality and deliverability of volumetric modulated arc therapy (VMAT), and to determine the most significant parameters in the generation of an ideal VMAT plan. Methods: A multi-dimensional exploratory statistical method, canonical correlation analysis (CCA) was adopted to study the correlations between VMAT parameters of complexity, quality and deliverability, as well as their contribution weights with 32 two-arc VMAT nasopharyngeal cancer (NPC) patients and 31 one-arc VMAT prostate cancer patients. Results: The MU per arc (MU/Arc) and MU per control point (MU/CP) of NPC were 337.8±25.2 and 3.7±0.3, respectively, whichmore » were significantly lower than those of prostate cancer patients (MU/Arc : 506.9±95.4, MU/CP : 5.6±1.1). The plan complexity indices indicated that two-arc VMAT plans were more complex than one-arc VMAT plans. Plan quality comparison confirmed that one-arc VMAT plans had a high quality than two-arc VMAT plans. CCA results implied that plan complexity parameters were highly correlated with plan quality with the first two canonical correlations of 0.96, 0.88 (both p<0.001) and significantly correlated with deliverability with the first canonical correlation of 0.79 (p<0.001), plan quality and deliverability was also correlated with the first canonical correlation of 0.71 (p=0.02). Complexity parameters of MU/CP, segment area (SA) per CP, percent of MU/CP less 3 and planning target volume (PTV) were weighted heavily in correlation with plan quality and deliveability . Similar results obtained from individual NPC and prostate CCA analysis. Conclusion: Relationship between complexity, quality, and deliverability parameters were investigated with CCA. MU, SA related parameters and PTV volume were found to have strong effect on the plan quality and deliverability. The presented correlation among different quantified parameters could be used to improve the plan quality and the

  11. Channeled polarimetric technique for the measurement of spectral dependence of linearly Stokes parameters

    NASA Astrophysics Data System (ADS)

    Quan, Naicheng; Zhang, Chunmin; Mu, Tingkui; Li, Qiwei

    2018-05-01

    The principle and experimental demonstration of a method based on channeled polarimetric technique (CPT) to measure spectrally resolved linearly Stokes parameters (SRLS) is presented. By replacing front retarder with an achromatic quarter wave-plate of CPT, the linearly SRLS can be measured simultaneously. It also retains the advantages of static and compact of CPT. Besides, comparing with CPT, it can reduce the RMS error by nearly a factor of 2-5 for the individual linear Stokes parameters.

  12. Measuring cosmological parameters

    PubMed Central

    Freedman, Wendy L.

    1998-01-01

    In this review, the status of measurements of the matter density (Ωm), the vacuum energy density or cosmological constant (ΩΛ), the Hubble constant (H0), and the ages of the oldest measured objects (t0) are summarized. Three independent types of methods for measuring the Hubble constant are considered: the measurement of time delays in multiply imaged quasars, the Sunyaev–Zel’dovich effect in clusters, and Cepheid-based extragalactic distances. Many recent independent dynamical measurements are yielding a low value for the matter density (Ωm ≈ 0.2–0.3). A wide range of Hubble constant measurements appear to be converging in the range of 60–80 km/sec per megaparsec. Areas where future improvements are likely to be made soon are highlighted—in particular, measurements of anisotropies in the cosmic microwave background. Particular attention is paid to sources of systematic error and the assumptions that underlie many of the measurement methods. PMID:9419315

  13. Can a Focus on Preventable Events Help Untangle the Quality Measurement Mess?

    PubMed

    Miller, Michael

    2016-01-01

    The success of a shift from paying for volume to paying for value depends on our ability to measure quality. Unfortunately, current approaches to measuring quality and linking quality to payment have frustrated providers and failed to provide essential information to patients. Shifting to a focus on preventable events could go a long way toward clarifying and simplifying quality measurement, but successful adoption of that approach requires overcoming several substantive and political challenges.

  14. Impact of fowlpox-vectored Mycoplasma gallisepticum vaccine Vectormune FP MG on layer hen egg production and egg quality parameters.

    PubMed

    Leigh, S A; Branton, S L; Evans, J D; Collier, S D

    2013-12-01

    This study was conducted to determine the impact of vaccination with Vectormune FP MG on egg production and egg quality characteristics of Single Comb White Leghorn hens. Due to questions of the efficacy of this vaccine in preventing Mycoplasma gallisepticum-mediated pathology, the ability of this vaccine to protect against postproduction-peak egg losses associated with F-strain M. gallisepticum (FMG) vaccination was also investigated. Vaccination with Vectormune FP MG did not result in any significant change in egg production or egg quality parameters compared with control (unvaccinated) hens. Subsequent revaccination with FMG at 45 wk of age (woa) yielded no impact on egg production or egg quality parameters of Vectormune FP MG vaccinated hens, unlike prior results for postproduction-peak vaccination of M. gallisepticum-clean hens with FMG, which exhibited a drop in egg production of approximately 6%. No difference in egg size distribution was observed for any of the treatment groups before or after FMG revaccination. These results suggest that hens can be safely vaccinated with Vectormune FP MG as pullets and can be revaccinated with a live M. gallisepticum vaccine such as FMG at a later date with no deleterious effects on egg production or egg or eggshell quality parameters.

  15. Assessing quality of care for migraineurs: a model health plan measurement set.

    PubMed

    Leas, Brian F; Gagne, Joshua J; Goldfarb, Neil I; Rupnow, Marcia F T; Silberstein, Stephen

    2008-08-01

    Quality of care measures are increasingly important to health plans, purchasers, physicians, and patients. Appropriate measures can be used to assess quality and evaluate improvement and are necessary components of pay-for-performance programs. Despite the broad scope of activity in the development of quality measures, migraine headache has received little attention. Given the enormous costs associated with migraine, especially in terms of lost productivity and preventable health care utilization, health plans could gain from a structured approach to measuring the quality of migraine care their beneficiaries receive. A potential migraine quality measurement set was developed through a review of migraine care literature and guidelines, interviews with leaders in migraine care, health care purchasing, and managed care, and the assembly of an advisory board. The board discussed candidate measures and established consensus on a testable measurement set. Twenty measures were developed, focused primarily on diagnosis and utilization. Areas of utilization include physician visits, emergency department visits, hospitalizations, and imaging. Use of both acute and preventive medications is included. More complex aspects of migraine care are also addressed, including triptan overuse, the relationship between acute and preventive medications, and follow-up after emergency department visits. The measures are currently being tested in health plans to assess their feasibility and value. A compelling case can be made for the development of migraine-specific quality measures for health plans. This effort to develop and test a starter set of measures should lead to new and innovative efforts to assess and improve quality of care for migraineurs.

  16. Recommended procedures for measuring aircraft noise and associated parameters

    NASA Technical Reports Server (NTRS)

    Marsh, A. H.

    1977-01-01

    Procedures are recommended for obtaining experimental values of aircraft flyover noise levels (and associated parameters). Specific recommendations are made for test criteria, instrumentation performance requirements, data-acquisition procedures, and test operations. The recommendations are based on state-of-the-art measurement capabilities available in 1976 and are consistent with the measurement objectives of the NASA Aircraft Noise Prediction Program. The recommendations are applicable to measurements of the noise produced by an airplane flying subsonically over (or past) microphones located near the surface of the ground. Aircraft types covered by the recommendations are fixed-wing airplanes powered by turbojet or turbofan engines and using conventional aerodynamic means for takeoff and landing. Various assumptions with respect to subsequent data processing and analysis were made (and are described) and the recommended measurement procedures are compatible with the assumptions. Some areas where additional research is needed relative to aircraft flyover noise measurement techniques are also discussed.

  17. Effect of pilot-scale aseptic processing on tomato soup quality parameters.

    PubMed

    Colle, Ines J P; Andrys, Anna; Grundelius, Andrea; Lemmens, Lien; Löfgren, Anders; Buggenhout, Sandy Van; Loey, Ann; Hendrickx, Marc Van

    2011-01-01

    Tomatoes are often processed into shelf-stable products. However, the different processing steps might have an impact on the product quality. In this study, a model tomato soup was prepared and the impact of pilot-scale aseptic processing, including heat treatment and high-pressure homogenization, on some selected quality parameters was evaluated. The vitamin C content, the lycopene isomer content, and the lycopene bioaccessibility were considered as health-promoting attributes. As a structural characteristic, the viscosity of the tomato soup was investigated. A tomato soup without oil as well as a tomato soup containing 5% olive oil were evaluated. Thermal processing had a negative effect on the vitamin C content, while lycopene degradation was limited. For both compounds, high-pressure homogenization caused additional losses. High-pressure homogenization also resulted in a higher viscosity that was accompanied by a decrease in lycopene bioaccessibility. The presence of lipids clearly enhanced the lycopene isomerization susceptibility and improved the bioaccessibility. The results obtained in this study are of relevance for product formulation and process design of tomato-based food products. © 2011 Institute of Food Technologists®

  18. Quality Assurance and Control Considerations in Environmental Measurements and Monitoring

    NASA Astrophysics Data System (ADS)

    Sedlet, Jacob

    1982-06-01

    Quality assurance and quality control have become accepted as essential parts of all environmental surveillance, measurements, and monitoring programs, both nuclear and non-nuclear. The same principles and details apply to each. It is primarily the final measurement technique that differs. As the desire and need to measure smaller amounts of pollutants with greater accuracy has increased, it has been recognized that quality assurance and control programs are cost-effective in achieving the expected results. Quality assurance (QA) consists of all the actions necessary to provide confidence in the results. Quality control (QC) is a part of QA, and consists of those actions and activities that permit the control of the individual steps in the environmental program. The distinction between the two terms is not always clearly defined, but a sharp division is not necessary. The essential principle of QA and QC is a commitment to high quality results. The essential components of a QA and QC program are a complete, written procedures manual for all parts of the environmental program, the use of standard or validated procedures, participation in applicable interlaboratory comparison or QA programs, replicate analysis and measurement, training of personnel, and a means of auditing or checking that the QA and QC programs are properly conducted. These components are discussed below in some detail.

  19. Quality measurement in physician-staffed emergency medical services: a systematic literature review.

    PubMed

    Haugland, Helge; Uleberg, Oddvar; Klepstad, Pål; Krüger, Andreas; Rehn, Marius

    2018-05-15

    Quality measurement of physician-staffed emergency medical services (P-EMS) is necessary to improve service quality. Knowledge and consensus on this topic are scarce, making quality measurement of P-EMS a high-priority research area. The aim of this review was to identify, describe and evaluate studies of quality measurement in P-EMS. The databases of MEDLINE and Embase were searched initially, followed by a search for included article citations in Scopus. The study eligibility criteria were: (1) articles describing the use of one quality indicator (QI) or more in P-EMS, (2) original manuscripts, (3) articles published from 1 January 1968 until 5 October 2016. The literature search identified 4699 records. 4543 were excluded after reviewing title and abstract. An additional 129 were excluded based on a full-text review. The remaining 27 papers were included in the analysis. Methodological quality was assessed using an adapted critical appraisal tool. The description of used QIs and methods of quality measurement was extracted. Variables describing the involved P-EMSs were extracted as well. In the included papers, a common understanding of which QIs to use in P-EMS did not exist. Fifteen papers used only a single QI. The most widely used QIs were 'Adherence to medical protocols', 'Provision of advanced interventions', 'Response time' and 'Adverse events'. The review demonstrated a lack of shared understanding of which QIs to use in P-EMS. Moreover, papers using only one QI dominated the literature, thus increasing the risk of a narrow perspective in quality measurement. Future quality measurement in P-EMS should rely on a set of consensus-based QIs, ensuring a comprehensive approach to quality measurement.

  20. Dual redundant arm system operational quality measures and their applications - Dynamic measures

    NASA Technical Reports Server (NTRS)

    Lee, Sukhan; Kim, Sungbok

    1990-01-01

    Dual-arm dynamic operation quality measures are presented which quantify the efficiency and capability of generating Cartesian accelerations by two cooperative arms based on the analysis of dual-arm dynamic interactions. Dual-arm dynamic manipulability is defined as the efficiency of generating Cartesian accelerations under the dynamic and kinematic interactions between individual arms and an object under manipulation. The analysis of dual-arm dynamic interactions is based on the so-called Cartesian space agent model of an arm, which represents an individual arm as a force source acting upon a point mass with the effective Cartesian space arm dynamics and an environment or an object under manipulation. The Cartesian space agent model of an arm makes it possible to derive the dynamic and kinematic constraints involved in the transport, assembly and grasping modes of dual-arm cooperation. A task-oriented operational quality measure, (TOQd) is defined by evaluating dual-arm dynamic manipulability in terms of given task requirements. TOQd is used in dual-arm joint configuration optimization. Simulation results are shown. A complete set of forward dynamic equations for a dual-arm system is derived, and dual-arm dynamic operational quality measures for various modes of dual-arm cooperation allowing sliding contacts are established.

  1. Using Indirect Turbulence Measurements for Real-Time Parameter Estimation in Turbulent Air

    NASA Technical Reports Server (NTRS)

    Martos, Borja; Morelli, Eugene A.

    2012-01-01

    The use of indirect turbulence measurements for real-time estimation of parameters in a linear longitudinal dynamics model in atmospheric turbulence was studied. It is shown that measuring the atmospheric turbulence makes it possible to treat the turbulence as a measured explanatory variable in the parameter estimation problem. Commercial off-the-shelf sensors were researched and evaluated, then compared to air data booms. Sources of colored noise in the explanatory variables resulting from typical turbulence measurement techniques were identified and studied. A major source of colored noise in the explanatory variables was identified as frequency dependent upwash and time delay. The resulting upwash and time delay corrections were analyzed and compared to previous time shift dynamic modeling research. Simulation data as well as flight test data in atmospheric turbulence were used to verify the time delay behavior. Recommendations are given for follow on flight research and instrumentation.

  2. Challenges and Opportunities in Using Patient-Reported Outcomes in Quality Measurement in Rheumatology

    PubMed Central

    Wahl, Elizabeth; Yazdany, Jinoos

    2016-01-01

    Summary Use of Patient-reported outcome measures (PROs) in rheumatology research is widespread, but use of PRO data to evaluate the quality of rheumatologic care delivered is less well established. This article reviews the use of PROs in assessing healthcare quality, and highlights challenges and opportunities specific to their use in rheumatology quality measurement. We first explore other countries’ experiences collecting and evaluating national PRO data to assess quality of care. We describe the current use of PROs as quality measures in rheumatology, and frame an agenda for future work supporting development of meaningful quality measures based on PROs. PMID:27133495

  3. Do prominent quality measurement surveys capture the concerns of persons with disability?

    PubMed

    Iezzoni, Lisa I; Marsella, Sarah A; Lopinsky, Tiffany; Heaphy, Dennis; Warsett, Kimberley S

    2017-04-01

    Demonstration programs nationwide aim to control costs and improve care for people dually-eligible for Medicare and Medicaid, including many persons with disability. Ensuring these initiatives maintain or improve care quality requires comprehensive evaluation of quality of care. To examine whether the common quality measures being used to evaluate the Massachusetts One Care duals demonstration program comprehensively address the concerns of persons with disability. Drawing upon existing conceptual frameworks, we developed a model of interrelationships of personal, health care, and environmental factors for achieving wellness for persons with disability. Based on this model, we specified a scheme to code individual quality measurement items and coded the items contained in 12 measures being used to assess Massachusetts One Care, which exclusively enrolls non-elderly adults with disability. Across these 12 measures, we assigned 376 codes to 302 items; some items received two codes. Taken together, the 12 measures contain items addressing most factors in our conceptual model that affect health care quality for persons with disability, including long-term services and supports. Some important gaps exist. No items examine sexual or reproductive health care, peer support, housing security, disability stigmatization, and specific services obtained outside the home like adult day care. Certain key concepts are covered only by a single or several of the 12 quality measures. Common quality metrics cover most - although not all-health care quality concerns of persons with disability. However, multiple different quality measures are required for this comprehensive coverage, raising questions about respondent burden. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Measuring and improving quality in university hospitals in Canada: The Collaborative for Excellence in Healthcare Quality.

    PubMed

    Backman, Chantal; Vanderloo, Saskia; Forster, Alan John

    2016-09-01

    Measuring and monitoring overall health system performance is complex and challenging but is crucial to improving quality of care. Today's health care organizations are increasingly being held accountable to develop and implement actions aimed at improving the quality of care, reducing costs, and achieving better patient-centered care. This paper describes the development of the Collaborative for Excellence in Healthcare Quality (CEHQ), a 5-year initiative to achieve higher quality of patient care in university hospitals across Canada. This bottom-up initiative took place between 2010 and 2015, and was successful in engaging health care leaders in the development of a common framework and set of performance measures for reporting and benchmarking, as well as working on initiatives to improve performance. Despite its successes, future efforts are needed to provide clear national leadership on standards for measuring performance. Copyright © 2016 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  5. Measurement of laser spot quality

    NASA Technical Reports Server (NTRS)

    Milster, T. D.; Treptau, J. P.

    1991-01-01

    Several ways of measuring spot quality are compared. We examine in detail various figures of merit such as full width at half maximum (FWHM), full width at 1/(e exp 2) maximum, Strehl ratio, and encircled energy. Our application is optical data storage, but results can be applied to other areas like space communications and high energy lasers. We found that the optimum figure of merit in many cases is Strehl ratio.

  6. Correlation and agreement of a digital and conventional method to measure arch parameters.

    PubMed

    Nawi, Nes; Mohamed, Alizae Marny; Marizan Nor, Murshida; Ashar, Nor Atika

    2018-01-01

    The aim of the present study was to determine the overall reliability and validity of arch parameters measured digitally compared to conventional measurement. A sample of 111 plaster study models of Down syndrome (DS) patients were digitized using a blue light three-dimensional (3D) scanner. Digital and manual measurements of defined parameters were performed using Geomagic analysis software (Geomagic Studio 2014 software, 3D Systems, Rock Hill, SC, USA) on digital models and with a digital calliper (Tuten, Germany) on plaster study models. Both measurements were repeated twice to validate the intraexaminer reliability based on intraclass correlation coefficients (ICCs) using the independent t test and Pearson's correlation, respectively. The Bland-Altman method of analysis was used to evaluate the agreement of the measurement between the digital and plaster models. No statistically significant differences (p > 0.05) were found between the manual and digital methods when measuring the arch width, arch length, and space analysis. In addition, all parameters showed a significant correlation coefficient (r ≥ 0.972; p < 0.01) between all digital and manual measurements. Furthermore, a positive agreement between digital and manual measurements of the arch width (90-96%), arch length and space analysis (95-99%) were also distinguished using the Bland-Altman method. These results demonstrate that 3D blue light scanning and measurement software are able to precisely produce 3D digital model and measure arch width, arch length, and space analysis. The 3D digital model is valid to be used in various clinical applications.

  7. What Is Nursing Home Quality and How Is It Measured?

    ERIC Educational Resources Information Center

    Castle, Nicholas G.; Ferguson, Jamie C.

    2010-01-01

    Purpose: In this commentary, we examine nursing home quality and indicators that have been used to measure nursing home quality. Design and Methods: A brief review of the history of nursing home quality is presented that provides some context and insight into currently used quality indicators. Donabedian's structure, process, and outcome (SPO)…

  8. Water quality parameters and total aerobic bacterial and vibrionaceae loads in eastern oysters (Crassostrea virginica) from oyster gardening sites

    USDA-ARS?s Scientific Manuscript database

    Oyster gardening is a practice designed to restore habitat for marine life and to improve water quality. This study determined physical and chemical water quality parameters at two oyster gardening sites in the Delaware Inland Bays and compared them with total aerobic bacteria and Vibrionaceae conc...

  9. What Is Nursing Home Quality and How Is It Measured?

    PubMed Central

    Castle, Nicholas G.; Ferguson, Jamie C.

    2010-01-01

    Purpose: In this commentary, we examine nursing home quality and indicators that have been used to measure nursing home quality. Design and Methods: A brief review of the history of nursing home quality is presented that provides some context and insight into currently used quality indicators. Donabedian's structure, process, and outcome (SPO) model is used to frame the discussion. Current quality indicators and quality initiatives are discussed, including those included in the Facility Quality Indicator Profile Report, Nursing Home Compare, deficiency citations included as part of Medicare/Medicaid certification, and the Advancing Excellence Campaign. Results: Current quality indicators are presented as a mix of structural, process, and outcome measures, each of which has noted advantages and disadvantages. We speculate on steps that need to be taken in the future to address and potentially improve the quality of care provided by nursing homes, including report cards, pay for performance, market-based incentives, and policy developments in the certification process. Areas for future research are identified throughout the review. Implications: We conclude that improvements in nursing home quality have likely occurred, but improvements are still needed. PMID:20631035

  10. A Foot-Arch Parameter Measurement System Using a RGB-D Camera

    PubMed Central

    Kong, Sejin; Mun, Kyung-Ryoul; Kim, Jinwook

    2017-01-01

    The conventional method of measuring foot-arch parameters is highly dependent on the measurer’s skill level, so accurate measurements are difficult to obtain. To solve this problem, we propose an autonomous geometric foot-arch analysis platform that is capable of capturing the sole of the foot and yields three foot-arch parameters: arch index (AI), arch width (AW) and arch height (AH). The proposed system captures 3D geometric and color data on the plantar surface of the foot in a static standing pose using a commercial RGB-D camera. It detects the region of the foot surface in contact with the footplate by applying the clustering and Markov random field (MRF)-based image segmentation methods. The system computes the foot-arch parameters by analyzing the 2/3D shape of the contact region. Validation experiments were carried out to assess the accuracy and repeatability of the system. The average errors for AI, AW, and AH estimation on 99 data collected from 11 subjects during 3 days were −0.17%, 0.95 mm, and 0.52 mm, respectively. Reliability and statistical analysis on the estimated foot-arch parameters, the robustness to the change of weights used in the MRF, the processing time were also performed to show the feasibility of the system. PMID:28777349

  11. Development of a Five-Dimensional Measure of Adult Sleep Quality

    ERIC Educational Resources Information Center

    Fortunato, Vincent J.; LeBourgeois, Monique K.; Harsh, John

    2008-01-01

    This article describes the development of a measure of adult sleep quality: the Adult Sleep-Wake Scale (ADSWS). The ADSWS is a self-report pencil-and-paper measure of sleep quality consisting of five behavioral dimensions (Going to Bed, Falling Asleep, Maintaining Sleep, Reinitiating Sleep, and Returning to Wakefulness). Data were collected from…

  12. Understanding Consumer Perceptions and Awareness of Hospital-Based Maternity Care Quality Measures.

    PubMed

    Maurer, Maureen; Firminger, Kirsten; Dardess, Pam; Ikeler, Kourtney; Sofaer, Shoshanna; Carman, Kristin L

    2016-06-01

    To explore factors that may influence use of comparative public reports for hospital maternity care. Four focus groups conducted in 2013 with 41 women and preintervention survey data collected in 2014 to 2015 from 245 pregnant women in North Carolina. As part of a larger randomized controlled trial, we conducted qualitative formative research to develop an intervention that will be evaluated through pre- and postintervention surveys. Analysis of focus group transcripts examined participants' perceptions of high-quality maternity care and the importance of different quality measures. Quantitative analysis included descriptive results of the preintervention survey and subgroup analyses to examine the impact of race, education, and being a first-time mom on outcomes. When describing high-quality maternity care, participants focused on interactions with providers, including respect for preferences and communication. The importance of quality measures was influenced by the extent to which they focused on babies' health, were perceived as the hospital's responsibility, and were perceived as representing "standard care." At baseline, 28 percent of survey respondents had used quality information to choose a hospital. Survey respondents were more aware of some quality measures (e.g., breastfeeding support) than others (e.g., episiotomy rates). Public reporting efforts could help increase relevance of maternity care quality measures by creating measures that reflect women's concerns, clearly explaining the hospital's role in supporting quality care, and showing how available quality measures can inform decisions about childbirth. © Health Research and Educational Trust.

  13. Incorporating Measures of Sleep Quality into Cancer Studies

    PubMed Central

    Redeker, Nancy S.; Pigeon, Wilfred R.; Boudreau, Eilis A.

    2014-01-01

    Introduction/background Sleep disturbance may influence the development of cancer and responses to treatment. It is also closely tied to recovery and quality of life in cancer patients, survivors, and caregivers, and recent studies have begun to show beneficial effects of sleep promoting interventions. Despite the importance of sleep to cancer and its treatment and the availability of numerous tools for measuring sleep quality and quantity, sleep measurements are underutilized in cancer studies. Methods This review, written for cancer researchers interested in incorporating sleep measures into their studies, is designed to raise awareness about the importance of sleep and suggest strategies for including sleep evaluation in cancer studies. Conclusions Inclusion of readily available sleep measures may ultimately improve cancer care by facilitating studies that lead to a greater understanding of how sleep and sleep disturbance influence all aspects of cancer care and the patient experience. PMID:25510361

  14. The feasibility of inflight measurement of lightning strike parameters

    NASA Technical Reports Server (NTRS)

    Crouch, K. E.; Plumer, J. A.

    1978-01-01

    The appearance of nonmetallic structural materials and microelectronics in aircraft design has resulted in a need for better knowledge of hazardous environments such as lightning and the effects these environments have on the aircraft. This feasibility study was performed to determine the lightning parameters in the greatest need of clarification and the performance requirements of equipment necessary to sense and record these parameters on an instrumented flight research aircraft. It was found that electric field rate of change, lightning currents, and induced voltages in aircraft wiring are the parameters of greatest importance. Flat-plate electric field sensors and resistive current shunts are proposed for electric field and current sensors, to provide direct measurements of these parameters. Six bit analog-to-digital signal conversion at a 5 nanosecond sampling rate, short-term storage of 85000 bits and long term storage of 5 x 10 to the 7th power bits of electric field, current and induced voltage data on the airplane are proposed, with readout and further analysis to be accomplished on the ground. A NASA F-106B was found to be suitable for use as the research aircraft because it has a minimum number of possible lightning attachment points, space for the necessary instrumentation, and appears to meet operational requirements. Safety considerations are also presented.

  15. Hydrological model parameter dimensionality is a weak measure of prediction uncertainty

    NASA Astrophysics Data System (ADS)

    Pande, S.; Arkesteijn, L.; Savenije, H.; Bastidas, L. A.

    2015-04-01

    This paper shows that instability of hydrological system representation in response to different pieces of information and associated prediction uncertainty is a function of model complexity. After demonstrating the connection between unstable model representation and model complexity, complexity is analyzed in a step by step manner. This is done measuring differences between simulations of a model under different realizations of input forcings. Algorithms are then suggested to estimate model complexity. Model complexities of the two model structures, SAC-SMA (Sacramento Soil Moisture Accounting) and its simplified version SIXPAR (Six Parameter Model), are computed on resampled input data sets from basins that span across the continental US. The model complexities for SIXPAR are estimated for various parameter ranges. It is shown that complexity of SIXPAR increases with lower storage capacity and/or higher recession coefficients. Thus it is argued that a conceptually simple model structure, such as SIXPAR, can be more complex than an intuitively more complex model structure, such as SAC-SMA for certain parameter ranges. We therefore contend that magnitudes of feasible model parameters influence the complexity of the model selection problem just as parameter dimensionality (number of parameters) does and that parameter dimensionality is an incomplete indicator of stability of hydrological model selection and prediction problems.

  16. Quality-of-life measures for use within care homes: a systematic review of their measurement properties.

    PubMed

    Aspden, Trefor; Bradshaw, Siobhan A; Playford, E Diane; Riazi, Afsane

    2014-09-01

    the aims of this review were (i) to identify quality-of-life (QoL) measures which have had their measurement properties validated in people residing in care homes or nursing homes, and to critically compare and summarise these instruments and (ii) to make recommendations for measurement instruments. bibliographic databases PsycINFO, PubMed, Cochrane, CINAHL and Embase were searched for articles evaluating measurement properties of QoL instruments in people residing in care homes. Methodological quality of studies was assessed using the consensus-based standards for the selection of health measurement instruments checklist. Measurement properties of instruments were appraised using a systematic checklist. the search strategy resulted in 3252 unique citations, of which 15 articles were included in this review. These articles assessed 13 instruments, 8 of which were dementia or Alzheimer specific instruments. The QUALIDEM, a dementia-specific observational instrument, had the widest array of information available on its measurement properties, which were mostly satisfactory. Most measurement instruments lacked information on hypotheses testing and content validity. Information on responsiveness and measurement error was not available for any instrument. for people with dementia living in care homes, the QUALIDEM is recommended for measuring QoL. For residents without dementia, we recommend Kane et al.'s Psychosocial Quality of Life Domains questionnaire. Studies of higher methodological quality, assessing a wider range of measurement properties are needed to allow a more fully informed choice of QoL instrument. © The Author 2014. Published by Oxford University Press on behalf of the British Geriatrics Society. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Changes in water quality parameters due to in-sewer processes.

    PubMed

    Boxall, J; Shepherd, W; Guymer, I; Fox, K

    2003-01-01

    Combined sewer systems contain a large number of organic and inorganic pollutants from both domestic and industrial sources. These pollutants are often retained within the combined sewer system for significant lengths of time before entering sewage treatment works, or being spilt to a watercourse via a combined sewer overflow (CSO) during storm conditions. Currently little knowledge exists concerning the effects of in sewer processes on pollutants. Understanding of in-sewer processes is important for the effective and efficient design of treatment works and CSO chambers and for impact assessments on receiving waters. A series of studies covering storm and dry weather flow conditions were undertaken with the aim of investigating the nature of in-sewer processes. These studies consisted of marking a body of water with a fluorescent tracer. The tracer was then monitored at a series of downstream sites, and discrete samples collected from the body of water as it progressed through the sewer. The samples were analysed for water quality parameters and these results investigated in tandem with the detailed hydraulic information gained through the tracer studies. The results highlight the hydraulic differences between storm and dry weather conditions such as increased travel times and mixing under storm conditions. The Advection Dispersion Equation (ADE) and Aggregated Dead Zone (ADZ) model parameters have been quantified for the tracer data. The ADE mixing coefficient is shown to increase by an order of magnitude for storm conditions. The ADZ dispersive fraction parameter is shown to be approximately constant with flow. Chemical reactions and decay within the sewer system were found to be consistent with oxygen limitation.

  18. Prediction of human gait parameters from temporal measures of foot-ground contact

    NASA Technical Reports Server (NTRS)

    Breit, G. A.; Whalen, R. T.

    1997-01-01

    Investigation of the influence of human physical activity on bone functional adaptation requires long-term histories of gait-related ground reaction force (GRF). Towards a simpler portable GRF measurement, we hypothesized that: 1) the reciprocal of foot-ground contact time (1/tc); or 2) the reciprocal of stride-period-normalized contact time (T/tc) predict peak vertical and horizontal GRF, loading rates, and horizontal speed during gait. GRF data were collected from 24 subjects while they walked and ran at a variety of speeds. Linear regression and ANCOVA determined the dependence of gait parameters on 1/tc and T/tc, and prediction SE. All parameters were significantly correlated to 1/tc and T/tc. The closest pooled relationship existed between peak running vertical GRF and T/tc (r2 = 0.896; SE = 3.6%) and improved with subject-specific regression (r2 = 0.970; SE = 2.2%). We conclude that temporal measures can predict force parameters of gait and may represent an alternative to direct GRF measurements for determining daily histories of habitual lower limb loading quantities necessary to quantify a bone remodeling stimulus.

  19. Barriers to adopting satellite remote sensing for water quality management

    EPA Science Inventory

    Satellite technology can provide a robust and synoptic approach for measuring water quality parameters. Water quality measures typically include chlorophyll-a, suspended material, light attenuation, and colored dissolved organic matter. The Hyperspectral Imager for the Coastal ...

  20. Quality of Care Measures for the Management of Unhealthy Alcohol Use

    PubMed Central

    Hepner, Kimberly A.; Watkins, Katherine E.; Farmer, Carrie M.; Rubenstein, Lisa; Pedersen, Eric R.; Pincus, Harold Alan

    2017-01-01

    There is a paucity of quality measures to assess the care for the range of unhealthy alcohol use, ranging from risky drinking to alcohol use disorders. Using a two-phase expert panel review process, we sought to develop an expanded set of quality of care measures for unhealthy alcohol use, focusing on outpatient care delivered in both primary care and specialty care settings. This process generated 25 candidate measures. Eight measures address screening and assessment, 11 address aspects of treatment, and six address follow-up. These quality measures represent high priority targets for future development, including creating detailed technical specifications and pilot testing them to evaluate their utility in terms of feasibility, reliability, and validity. PMID:28340902

  1. Data Quality Parameters and Web Services Facilitate User Access to Research-Ready Seismic Data

    NASA Astrophysics Data System (ADS)

    Trabant, C. M.; Templeton, M. E.; Van Fossen, M.; Weertman, B.; Ahern, T. K.; Casey, R. E.; Keyson, L.; Sharer, G.

    2016-12-01

    IRIS Data Services has the mission of providing efficient access to a wide variety of seismic and related geoscience data to the user community. With our vast archive of freely available data, we recognize that there is a constant challenge to provide data to scientists and students that are of a consistently useful level of quality. To address this issue, we began by undertaking a comprehensive survey of the data and generating metrics measurements that provide estimates of data quality. These measurements can inform the scientist of the level of suitability of a given set of data for their scientific investigation. They also serve as a quality assurance check for network operators, who can act on this information to improve their current recording or mitigate issues with already recorded data and metadata. Following this effort, IRIS Data Services is moving forward to focus on providing tools for the scientist that make it easier to access data of a quality and characteristic that suits their investigation. Data that fulfill this criterion are termed "research-ready". In addition to filtering data by type, geographic location, proximity to events, and specific time ranges, we will offer the ability to filter data based on specific quality assessments. These include signal-to-noise ratio measurements, data continuity, timing quality, absence of channel cross-talk, and potentially many other factors. Our goal is to ensure that the user receives only the data that meets their specifications and will not require extensive review and culling after delivery. We will present the latest developments of the MUSTANG automated data quality system and introduce the Research-Ready Data Sets (RRDS) service. Together these two technologies serve as a data quality assurance ecosystem that will provide benefit to the scientific community by aiding efforts to readily find appropriate and suitable data for use in any number of objectives.

  2. Effect of e-learning on quality of cervical-length measurements.

    PubMed

    van Os, M A; van der Ven, A J; Bloemendaal, P M; Pajkrt, E; de Groot, C J M; Mol, B W J; Haak, M C

    2015-09-01

    To assess the effect of implementation of a newly developed e-learning module on the quality of cervical-length measurements. With the introduction of cervical-length (CL) measurement in a research setting, a CL measurement e-learning module (CLEM) was developed with the purpose to enhance the knowledge and skills of experienced ultrasonographers. CLEM was designed specifically for ultrasonographers who perform ultrasound in a general obstetrical practice but who do not regularly perform CL measurements. CLEM consists of five theoretical questions and three caliper-placement tests to learn the CL measurement technique. The quality of the CL measurements of CLEM participants was compared with images of non-participants using a CL measurement image score (CIS), defined as the sum of six items which assess the quality of the image. Each CLEM participant submitted five CL images and the images of non-CLEM participants were selected randomly from an ultrasound database. The CIS of the CLEM participants (n = 61) were significantly higher than those of non-CLEM participants (n = 23) (164.9 vs 155.6, respectively; P = 0.03). Visualization of the internal os and positioning of the calipers on the internal and external ora were found to have significantly higher CIS among the CLEM participants than among the non-CLEM participants (P = 0.001 and P < 0.001, respectively). Introducing CLEM may improve the quality of CL measurements obtained by trained and untrained sonographers. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.

  3. Measurements of the Temperature Structure-Function Parameters with a Small Unmanned Aerial System Compared with a Sodar

    NASA Astrophysics Data System (ADS)

    Bonin, Timothy A.; Goines, David C.; Scott, Aaron K.; Wainwright, Charlotte E.; Gibbs, Jeremy A.; Chilson, Phillip B.

    2015-06-01

    The structure function is often used to quantify the intensity of spatial inhomogeneities within turbulent flows. Here, the Small Multifunction Research and Teaching Sonde (SMARTSonde), an unmanned aerial system, is used to measure horizontal variations in temperature and to calculate the structure function of temperature at various heights for a range of separation distances. A method for correcting for the advection of turbulence in the calculation of the structure function is discussed. This advection correction improves the data quality, particularly when wind speeds are high. The temperature structure-function parameter can be calculated from the structure function of temperature. Two case studies from which the SMARTSonde was able to take measurements used to derive at several heights during multiple consecutive flights are discussed and compared with sodar measurements, from which is directly related to return power. Profiles of from both the sodar and SMARTSonde from an afternoon case exhibited generally good agreement. However, the profiles agreed poorly for a morning case. The discrepancies are partially attributed to different averaging times for the two instruments in a rapidly evolving environment, and the measurement errors associated with the SMARTSonde sampling within the stable boundary layer.

  4. Rocket measurements within a polar cap arc - Plasma, particle, and electric circuit parameters

    NASA Technical Reports Server (NTRS)

    Weber, E. J.; Ballenthin, J. O.; Basu, S.; Carlson, H. C.; Hardy, D. A.; Maynard, N. C.; Kelley, M. C.; Fleischman, J. R.; Pfaff, R. F.

    1989-01-01

    Results are presented from the Polar Ionospheric Irregularities Experiment (PIIE), conducted from Sondrestrom, Greenland, on March 15, 1985, designed for an investigation of processes which lead to the generation of small-scale (less than 1 km) ionospheric irregularities within polar-cap F-layer auroras. An instrumented rocket was launched into a polar cap F layer aurora to measure energetic electron flux, plasma, and electric circuit parameters of a sun-aligned arc, coordinated with simultaneous measurements from the Sondrestrom incoherent scatter radar and the AFGL Airborne Ionospheric Observatory. Results indicated the existence of two different generation mechanisms on the dawnside and duskside of the arc. On the duskside, parameters are suggestive of an interchange process, while on the dawnside, fluctuation parameters are consistent with a velocity shear instability.

  5. The quality of systematic reviews of health-related outcome measurement instruments.

    PubMed

    Terwee, C B; Prinsen, C A C; Ricci Garotti, M G; Suman, A; de Vet, H C W; Mokkink, L B

    2016-04-01

    Systematic reviews of outcome measurement instruments are important tools for the selection of instruments for research and clinical practice. Our aim was to assess the quality of systematic reviews of health-related outcome measurement instruments and to determine whether the quality has improved since our previous study in 2007. A systematic literature search was performed in MEDLINE and EMBASE between July 1, 2013, and June 19, 2014. The quality of the reviews was rated using a study-specific checklist. A total of 102 reviews were included. In many reviews the search strategy was considered not comprehensive; in only 59 % of the reviews a search was performed in EMBASE and in about half of the reviews there was doubt about the comprehensiveness of the search terms used for type of measurement instruments and measurement properties. In 41 % of the reviews, compared to 30 % in our previous study, the methodological quality of the included studies was assessed. In 58 %, compared to 55 %, the quality of the included instruments was assessed. In 42 %, compared to 7 %, a data synthesis was performed in which the results from multiple studies on the same instrument were somehow combined. Despite a clear improvement in the quality of systematic reviews of outcome measurement instruments in comparison with our previous study in 2007, there is still room for improvement with regard to the search strategy, and especially the quality assessment of the included studies and the included instruments, and the data synthesis.

  6. Vocal parameters and voice-related quality of life in adult women with and without ovarian function.

    PubMed

    Ferraz, Pablo Rodrigo Rocha; Bertoldo, Simão Veras; Costa, Luanne Gabrielle Morais; Serra, Emmeliny Cristini Nogueira; Silva, Eduardo Magalhães; Brito, Luciane Maria Oliveira; Chein, Maria Bethânia da Costa

    2013-05-01

    To identify the perceptual and acoustic parameters of voice in adult women with and without ovarian function and its impact on quality of life related to voice. Cross-sectional and analytical study with 106 women divided into, two groups: G1, with ovarian function (n=43) and G2, without physiological ovarian function (n=63). The women were instructed to sustain the vowel "a" and the sounds of /s/ and /z/ in habitual pitch and loudness. They were also asked to classify their voices and answer the voice-related quality of life (V-RQOL) questionnaire. The perceptual analysis of the vocal samples was performed by three speech-language pathologists using the GRBASI (G: grade; R: roughness; B: breathness; A: asthenia; S: strain; I: instability) scale. The acoustic analysis was carried out with the software VoxMetria 2.7h (CTS Informatica). The data were analyzed using descriptive statistics. In the perceptual analysis, both groups showed a mild deviation for the parameters roughness, strain, and instability, but only G2 showed a mild impact for the overall degree of dysphonia. The mean of fundamental frequency was significantly lower for the G2, with a difference of 17.41Hz between the two groups. There was no impact on V-RQOL in any of the V-RQOL domains for this group. With the menopause, there is a change in women's voices, impacting on some voice parameters. However, there is no direct impact on their quality of life related to voice. Copyright © 2013 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  7. Thoracic Inlet Parameters for Degenerative Cervical Spondylolisthesis Imaging Measurement.

    PubMed

    Wang, Quanbing; Wang, Xiao-Tao; Zhu, Lei; Wei, Yu-Xi

    2018-04-05

    BACKGROUND The aim of this study was to explore the diagnostic value of sagittal measurement of thoracic inlet parameters for degenerative cervical spondylolisthesis (DCS). MATERIAL AND METHODS We initially included 65 patients with DCS and the same number of health people as the control group by using cervical radiograph evaluations. We analyzed the x-ray and computer tomographic (CT) data in prone and standing position at the same time. Measurement of cervical sagittal parameters was carried out in a standardized supine position. Multivariate logistic regression analysis was performed to evaluate these parameters as a diagnostic index for DCS. RESULTS There were 60 cases enrolled in the DCS group, and 62 cases included in the control group. The T1 slope and thoracic inlet angle (TIA) were significantly greater for the DCS group compared to the control group (24.33±2.85º versus 19.59±2.04º, p=0.00; 76.11±9.82º versus 72.86±7.31º, p=0.03, respectively). We observed no significant difference for the results of the neck tilt (NT), C2-C7 angle in the control and the DSC group (p>0.05). Logistic regression analysis and receiver operating characteristic (ROC) curve revealed that preoperative T1 slope of more than 22.0º showed significantly diagnostic value for the DCS group (p<0.05). CONCLUSIONS Patients with preoperative sagittal imbalance of thoracic inlet have a statistically significant increased risk of DCS. T1 slope of more than 22.0º showed significantly diagnostic value for the incidence of DCS.

  8. The Development of Quality Measures for the Performance and Interpretation of Esophageal Manometry

    PubMed Central

    Yadlapati, Rena; Gawron, Andrew J.; Keswani, Rajesh N.; Bilimoria, Karl; Castell, Donald O.; Dunbar, Kerry B.; Gyawali, Chandra P.; Jobe, Blair A.; Katz, Philip O.; Katzka, David A.; Lacy, Brian E.; Massey, Benson T.; Richter, Joel E.; Schnoll-Sussman, Felice; Spechler, Stuart J.; Tatum, Roger; Vela, Marcelo F.; Pandolfino, John E.

    2016-01-01

    Background and Aims Esophageal manometry (EM) is the gold standard for the diagnosis of esophageal motility disorders. Variations in the performance and interpretation of EM result in discrepant diagnoses and unnecessary repeated procedures, and may negatively impact patient outcomes. A method to benchmark the procedural quality of EM is needed. The primary aim of this study was to develop quality measures for performing and interpreting EM. Methods The RAND/University of California, Los Angeles Appropriateness Methodology (RAM) was utilized. Fifteen experts in esophageal manometry were invited to be a part of the panel. Potential quality measures were identified through a literature search and interviews with experts. The expert panel ranked the proposed quality measures for appropriateness via a two-round process on the basis of RAM. Results Fourteen experts participated in all processes. A total of 29 measures were considered; 17 of these measures were ranked as appropriate and related to competency (2), pre-procedure (2), procedure (3) and interpretation (10). The latter 10 were integrated into a single composite measure. Thus, 8 final measures were determined to be appropriate quality measures for EM. Five strong recommendations were also endorsed by the experts, however they were not ranked as appropriate quality measures. Conclusions Eight formally validated quality measures for the performance and interpretation of EM were developed on the basis of RAM. These measures represent key aspects of a high-quality EM study and should be uniformly adopted. Evaluation of these measures in clinical practice is needed to assess their impact on outcomes. PMID:26499925

  9. Development of near-infrared spectroscopy calibrations to measure quality characteristics in intact Brassicaceae germplasm

    USDA-ARS?s Scientific Manuscript database

    Determining seed quality parameters is an integral part of cultivar improvement and germplasm screening. However, quality tests are often time cnsuming, seed destructive, and can require large seed samples. This study describes the development of near-infrared spectroscopy (NIRS) calibrations to mea...

  10. Image quality phantom and parameters for high spatial resolution small-animal SPECT

    NASA Astrophysics Data System (ADS)

    Visser, Eric P.; Harteveld, Anita A.; Meeuwis, Antoi P. W.; Disselhorst, Jonathan A.; Beekman, Freek J.; Oyen, Wim J. G.; Boerman, Otto C.

    2011-10-01

    At present, generally accepted standards to characterize small-animal single photon emission tomographs (SPECT) do not exist. Whereas for small-animal positron emission tomography (PET), the NEMA NU 4-2008 guidelines are available, such standards are still lacking for small-animal SPECT. More specifically, a dedicated image quality (IQ) phantom and corresponding IQ parameters are absent. The structures of the existing PET IQ phantom are too large to fully characterize the sub-millimeter spatial resolution of modern multi-pinhole SPECT scanners, and its diameter will not fit into all scanners when operating in high spatial resolution mode. We therefore designed and constructed an adapted IQ phantom with smaller internal structures and external diameter, and a facility to guarantee complete filling of the smallest rods. The associated IQ parameters were adapted from NEMA NU 4. An additional parameter, effective whole-body sensitivity, was defined since this was considered relevant in view of the variable size of the field of view and the use of multiple bed positions as encountered in modern small-animal SPECT scanners. The usefulness of the phantom was demonstrated for 99mTc in a USPECT-II scanner operated in whole-body scanning mode using a multi-pinhole mouse collimator with 0.6 mm pinhole diameter.

  11. The Role of Measurement Quality on Practical Guidelines for Assessing Measurement and Structural Invariance

    ERIC Educational Resources Information Center

    Kang, Yoonjeong; McNeish, Daniel M.; Hancock, Gregory R.

    2016-01-01

    Although differences in goodness-of-fit indices (?GOFs) have been advocated for assessing measurement invariance, studies that advanced recommended differential cutoffs for adjudicating invariance actually utilized a very limited range of values representing the quality of indicator variables (i.e., magnitude of loadings). Because quality of…

  12. Investigating the CO 2 laser cutting parameters of MDF wood composite material

    NASA Astrophysics Data System (ADS)

    Eltawahni, H. A.; Olabi, A. G.; Benyounis, K. Y.

    2011-04-01

    Laser cutting of medium density fibreboard (MDF) is a complicated process and the selection of the process parameters combinations is essential to get the highest quality cut section. This paper presents a means for selecting the process parameters for laser cutting of MDF based on the design of experiments (DOE) approach. A CO 2 laser was used to cut three thicknesses, 4, 6 and 9 mm, of MDF panels. The process factors investigated are: laser power, cutting speed, air pressure and focal point position. In this work, cutting quality was evaluated by measuring the upper kerf width, the lower kerf width, the ratio between the upper kerf width to the lower kerf width, the cut section roughness and the operating cost. The effect of each factor on the quality measures was determined. The optimal cutting combinations were presented in favours of high quality process output and in favours of low cutting cost.

  13. OHIO RIVER WATER QUALITY ASSESSMENT USING LANDSAT-7 DATA

    EPA Science Inventory

    The objectives of this project were (1) to develop a universal index for measuring Turbidity and Chlorophyll-A from remote sensing data and (2) to correlate satellite image parameters from Landsat-7 data with field measurements of water quality for five parameters: Chlorophyll-A ...

  14. Measuring Website Quality: Asymmetric Effect of User Satisfaction

    ERIC Educational Resources Information Center

    Kincl, Tomas; Strach, Pavel

    2012-01-01

    Website quality measurement tools have been largely static and have struggled to determine relevant attributes of user satisfaction. This study compares and contrasts attributes of user satisfaction based on usability guidelines seeking to identify practical easy-to-administer measurement tools. The website users assessed business school homepages…

  15. The determination of the acoustic parameters of volcanic rocks from compressional velocity measurements

    USGS Publications Warehouse

    Carroll, R.D.

    1969-01-01

    A statistical analysis was made of the relationship of various acoustic parameters of volcanic rocks to compressional wave velocities for data obtained in a volcanic region in Nevada. Some additional samples, chiefly granitic rocks, were also included in the study to extend the range of parameters and the variety of siliceous rock types sampled. Laboratory acoustic measurements obtained on 62 dry core samples were grouped with similar measurements obtained from geophysical logging devices at several depth intervals in a hole from which 15 of the core samples had been obtained. The effects of lithostatic and hydrostatic load on changing the rock acoustic parameters measured in the hole were noticeable when compared with the laboratory measurements on the same core. The results of the analyses determined by grouping all of the data, however, indicate that dynamic Young's, shear and bulk modulus, shear velocity, shear and compressional characteristic impedance, as well as amplitude and energy reflection coefficients may be reliably estimated on the basis of the compressional wave velocities of the rocks investigated. Less precise estimates can be made of density based on the rock compressional velocity. The possible extension of these relationships to include many siliceous rocks is suggested. ?? 1969.

  16. CAN RAPID MEASURES OF RECREATIONAL WATER QUALITY PREDICT SWIMMING ASSOCIATED GASTROINTESTINAL ILLNESS?

    EPA Science Inventory

    Standard methods to measure recreational water quality require at least 24 hours to obtain results making it impossible to assess the quality of water within a single day. Methods to measure recreational water quality in two hours or less have been developed. Application of rapid...

  17. Applicability of strain measurements on a contra angle handpiece for the determination of alveolar bone quality during dental implant surgery.

    PubMed

    Krafft, Tim; Winter, Werner; Wichmann, Manfred; Karl, Matthias

    2012-07-01

    Alveolar bone quality is considered to be an important prognostic factor in dental implant stability. Although numerous methods have been described, no technique allows for reliable diagnostics. The purpose of this study was to determine if strain measurements on the shaft of a contra angle handpiece during implant bed preparation could be used for the determination of bone quality. Experiments in polyurethane foam and human cadaver bone were conducted to investigate whether strain measurements could be correlated with other diagnostic parameters, such as the surgeon's tactile sensation during drilling, implant insertion torque, implant stability, elastic modulus of bone and bone quality as assessed radiographically. Tests were also performed to determine if strain measurements could be used to distinguish various types of bone. As axial feed and contact pressure during the drilling process could not be standardized under simulated clinical conditions, substantial deviations in the time needed to complete the drilling occurred. Under controlled circumstances using polyurethane foam, this problem could be addressed by a normalization procedure, but great variations occurred in human cadaver bone. As bone quality could not be reliably determined, especially when a cortical layer was present, strain measurements on a contra angle handpiece appears to be inappropriate for this purpose. Copyright © 2011 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  18. Measuring and Costing Quality in Education: Using Quality and Productivity Methods To Improve Schools.

    ERIC Educational Resources Information Center

    Spanbauer, Stanley J.

    The Measurement and Costing Model (MCM) described in this book was developed and tested at Fox Valley Technical College (FVTC), Wisconsin, to enhance the college's quality improvement process and to serve as a guide to other institutions interested in improving their quality. The book presents a description of the model and outlines seven steps…

  19. Material parameter determination from scattering measurements

    NASA Technical Reports Server (NTRS)

    Dominek, A.; Park, A.; Peters, L., Jr.

    1988-01-01

    The electrical, macroscopic performance of isotropic material can generally be described through their constitutive scalar parameters, permittivity and permeability which are symbolically represented by epsilon and mu, respectively. These parameters relate the electric and magnetic flux densities to the electric and magnetic fields through the following relationships: (1) D=epsilonE; and (2) B=muH. It is through these parameters that the interaction of electromagnetic waves with material can be quantized in terms of reflection and transmission coefficients, and propagation and attenuation factors.

  20. Constitutive parameter measurements of lossy materials

    NASA Technical Reports Server (NTRS)

    Dominek, A.; Park, A.

    1989-01-01

    The electrical constitutive parameters of lossy materials are considered. A discussion of the NRL arch for lossy coatings is presented involving analytical analyses of the reflected field using the geometrical theory of diffraction (GTD) and physical optics (PO). The actual values for these parameters can be obtained through a traditional transmission technique which is examined from an error analysis standpoint. Alternate sample geometries are suggested for this technique to reduce sample tolerance requirements for accurate parameter determination. The performance for one alternate geometry is given.

  1. A comment on the validity of fragmentation parameters measured in nuclear emulsions. [cosmic ray nuclei

    NASA Technical Reports Server (NTRS)

    Waddington, C. J.

    1978-01-01

    Evidence is reexamined which has been cited as suggesting serious errors in the use of fragmentation parameters appropriate to an airlike medium deduced from measurements made in nuclear emulsions to evaluate corrections for certain effects in balloon-borne observations of cosmic-ray nuclei. Fragmentation parameters for hydrogenlike interactions are calculated and shown to be in overall good agreement with those obtained previously for air. Experimentally measured fragmentation parameters in emulsion are compared with values computed semiempirically, and reasonable agreement is indicated.

  2. Optical steam quality measurement system and method

    DOEpatents

    Davidson, James R.; Partin, Judy K.

    2006-04-25

    An optical measurement system is presented that offers precision on-line monitoring of the quality of steam. Multiple wavelengths of radiant energy are passed through the steam from an emitter to a detector. By comparing the amount of radiant energy absorbed by the flow of steam for each wavelength, a highly accurate measurement of the steam quality can be determined on a continuous basis in real-time. In an embodiment of the present invention, the emitter, comprises three separate radiant energy sources for transmitting specific wavelengths of radiant energy through the steam. In a further embodiment, the wavelengths of radiant energy are combined into a single beam of radiant energy for transmission through the steam using time or wavelength division multiplexing. In yet a further embodiment, the single beam of radiant energy is transmitted using specialized optical elements.

  3. Spatial patterns of water quality parameters in upper layer of the Kara Sea in summer 2016 based on laser remote sensing

    NASA Astrophysics Data System (ADS)

    Osokina, Varvara; Pelevin, Vadim; Shatravin, Alexander; Belyaev, Nikolay; Demidov, Andrey; Redzhepova, Zuleyha

    2017-04-01

    The paper represents results of remote sensing by means of Laser Induced Fluorescence LiDAR during the expedition in Kara Sea in summer 2016. The expedition took place in Western and Southern parts of Kara Sea including Ob and Yenisei areas from June, 14 to August, 20 2016. The LiDAR observations were obtained from the research vessel Mstislav Keldysh and included 4600 km of almost continuous measurements and 94 complex stations. As a result now there is a vast LiDAR database available for scientific purposes. The data were processed and recalculated providing a set of high resolution maps of distribution of main oceanographic water quality parameters including chlorophyll "a", total organic carbon and total suspended matter in surface layer. The proceeded maps give a precise information about the location of frontal zones between Ob and Yenisei waters and Kara Sea waters, provide a detailed picture of complex surface water structure in central Kara Sea and other locations and present data about spatial distinction of concentrations of measured water parameters. The LiDAR measurements were afterwards compared to data, obtained by underway flow-through CTD measuring system and satellite images providing adjunct information on water parameters' distribution features. The instruments of UFL (Ultraviolet fluorescent LiDAR) series were developed by the Shirshov Institute of Oceanology, Moscow, Russia, and have been successfully used in lots of scientific expeditions in different water areas. UFL LiDARs take measurements with sampling rate up to 2 Hz from the vessel under way in any weather or sunlight conditions. The measurements are linked to a GPS, and so all data are geo-tagged and can be used to create interpolated maps of the measured parameters. The instrument analyses backward signal from dual excitation (355, 532 nm) laser pulses emitted at 2 Hz. The signal is detected across 11 bands in series (355, 385, 404, 424, 440, 460, 499, 532, 620, 651, 685 nm) on

  4. Quality Measures for Dialysis: Time for a Balanced Scorecard.

    PubMed

    Kliger, Alan S

    2016-02-05

    Recent federal legislation establishes a merit-based incentive payment system for physicians, with a scorecard for each professional. The Centers for Medicare and Medicaid Services evaluate quality of care with clinical performance measures and have used these metrics for public reporting and payment to dialysis facilities. Similar metrics may be used for the future merit-based incentive payment system. In nephrology, most clinical performance measures measure processes and intermediate outcomes of care. These metrics were developed from population studies of best practice and do not identify opportunities for individualizing care on the basis of patient characteristics and individual goals of treatment. The In-Center Hemodialysis (ICH) Consumer Assessment of Healthcare Providers and Systems (CAHPS) survey examines patients' perception of care and has entered the arena to evaluate quality of care. A balanced scorecard of quality performance should include three elements: population-based best clinical practice, patient perceptions, and individually crafted patient goals of care. Copyright © 2016 by the American Society of Nephrology.

  5. Quality Measures for Dialysis: Time for a Balanced Scorecard

    PubMed Central

    2016-01-01

    Recent federal legislation establishes a merit-based incentive payment system for physicians, with a scorecard for each professional. The Centers for Medicare and Medicaid Services evaluate quality of care with clinical performance measures and have used these metrics for public reporting and payment to dialysis facilities. Similar metrics may be used for the future merit-based incentive payment system. In nephrology, most clinical performance measures measure processes and intermediate outcomes of care. These metrics were developed from population studies of best practice and do not identify opportunities for individualizing care on the basis of patient characteristics and individual goals of treatment. The In-Center Hemodialysis (ICH) Consumer Assessment of Healthcare Providers and Systems (CAHPS) survey examines patients' perception of care and has entered the arena to evaluate quality of care. A balanced scorecard of quality performance should include three elements: population-based best clinical practice, patient perceptions, and individually crafted patient goals of care. PMID:26316622

  6. Measurements of gas parameters in plasma-assisted supersonic combustion processes using diode laser spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bolshov, Mikhail A; Kuritsyn, Yu A; Liger, V V

    2009-09-30

    We report a procedure for temperature and water vapour concentration measurements in an unsteady-state combustion zone using diode laser absorption spectroscopy. The procedure involves measurements of the absorption spectrum of water molecules around 1.39 {mu}m. It has been used to determine hydrogen combustion parameters in M = 2 gas flows in the test section of a supersonic wind tunnel. The relatively high intensities of the absorption lines used have enabled direct absorption measurements. We describe a differential technique for measurements of transient absorption spectra, the procedure we used for primary data processing and approaches for determining the gas temperature andmore » H{sub 2}O concentration in the probed zone. The measured absorption spectra are fitted with spectra simulated using parameters from spectroscopic databases. The combustion-time-averaged ({approx}50 ms) gas temperature and water vapour partial pressure in the hot wake region are determined to be 1050 K and 21 Torr, respectively. The large signal-to-noise ratio in our measurements allowed us to assess the temporal behaviour of these parameters. The accuracy in our temperature measurements in the probed zone is {approx}40 K. (laser applications and other topics in quantum electronics)« less

  7. Effect of clinical and laboratory parameters on quality of life in celiac patients using celiac disease-specific quality of life scores.

    PubMed

    Lee, Jungmin; Clarke, Kofi

    2017-11-01

    Health-related quality of life (HR-QOL) in patients with celiac disease is reduced compared to the general population. We investigated the association between HR-QOL and clinical, laboratory findings using the previously validated CD-QOL (celiac disease-specific quality of life) instrument in patients with celiac disease. To our knowledge, no study has previously explored the relationship between HR-QOL and clinical, laboratory parameters in celiac patients. Patients who received care at the Allegheny Health Network Celiac Center, Pittsburgh, PA were asked to complete the CD-QOL questionnaire. A cross sectional study with predetermined clinical and laboratory parameters was performed. Data collected included IgA anti-tissue transglutaminase (tTG) antibody titers, iron studies, calcium, vitamin A, B12, 25 OH vitamin D, and E levels. Correlation between clinical findings and CD-QOL was also assessed. Seventy-eight out of 124 patients who completed the questionnaire was included in the analysis. Patients with concomitant irritable bowel syndrome (IBS) had significantly reduced HR-QOL with CD-QOL score of 52.4 ± 11.3 vs. 44.6 ± 12.9 in those without IBS (p = .009). There was no difference in HR-QOL in relation to IgA tTG titers or vitamin D levels. Of note, there was a trend towards correlation between higher level of vitamin E and better QOL (r = -0.236, p = .074). Celiac patients with concomitant IBS have reduced HR-QOL. There was no statistically significant association between HR-QOL and laboratory parameters or levels of micronutrients.

  8. Prediction of betavoltaic battery output parameters based on SEM measurements and Monte Carlo simulation.

    PubMed

    Yakimov, Eugene B

    2016-06-01

    An approach for a prediction of (63)Ni-based betavoltaic battery output parameters is described. It consists of multilayer Monte Carlo simulation to obtain the depth dependence of excess carrier generation rate inside the semiconductor converter, a determination of collection probability based on the electron beam induced current measurements, a calculation of current induced in the semiconductor converter by beta-radiation, and SEM measurements of output parameters using the calculated induced current value. Such approach allows to predict the betavoltaic battery parameters and optimize the converter design for any real semiconductor structure and any thickness and specific activity of beta-radiation source. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Effect of combined digital imaging parameters on endodontic file measurements.

    PubMed

    de Oliveira, Matheus Lima; Pinto, Geraldo Camilo de Souza; Ambrosano, Glaucia Maria Bovi; Tosoni, Guilherme Monteiro

    2012-10-01

    This study assessed the effect of the combination of a dedicated endodontic filter, spatial resolution, and contrast resolution on the determination of endodontic file lengths. Forty extracted single-rooted teeth were x-rayed with K-files (ISO size 10 and 15) in the root canals. Images were acquired using the VistaScan system (Dürr Dental, Beitigheim-Bissingen, Germany) under different combining parameters of spatial resolution (10 and 25 line pairs per millimeter [lp/mm]) and contrast resolution (8- and 16-bit depths). Subsequently, a dedicated endodontic filter was applied on the 16-bit images, creating 2 additional parameters. Six observers measured the length of the endodontic files in the root canals using the software that accompanies the system. The mean values of the actual file lengths and the measurements of the radiographic images were submitted to 1-way analysis of variance and the Tukey test at a level of significance of 5%. The intraobserver reproducibility was assessed by the intraclass correlation coefficient. All combined image parameters showed excellent intraobserver agreement with intraclass correlation coefficient means higher than 0.98. The imaging parameter of 25 lp/mm and 16 bit associated with the use of the endodontic filter did not differ significantly from the actual file lengths when both file sizes were analyzed together or separately (P > .05). When the size 15 file was evaluated separately, only 8-bit images differed significantly from the actual file lengths (P ≤ .05). The combination of an endodontic filter with high spatial resolution and high contrast resolution is recommended for the determination of file lengths when using storage phosphor plates. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  10. Measurement and simulation of the TRR BNCT beam parameters

    NASA Astrophysics Data System (ADS)

    Bavarnegin, Elham; Sadremomtaz, Alireza; Khalafi, Hossein; Kasesaz, Yaser; Golshanian, Mohadeseh; Ghods, Hossein; Ezzati, Arsalan; Keyvani, Mehdi; Haddadi, Mohammad

    2016-09-01

    Recently, the configuration of the Tehran Research Reactor (TRR) thermal column has been modified and a proper thermal neutron beam for preclinical Boron Neutron Capture Therapy (BNCT) has been obtained. In this study, simulations and experimental measurements have been carried out to identify the BNCT beam parameters including the beam uniformity, the distribution of the thermal neutron dose, boron dose, gamma dose in a phantom and also the Therapeutic Gain (TG). To do this, the entire TRR structure including the reactor core, pool, the thermal column and beam tubes have been modeled using MCNPX Monte Carlo code. To measure in-phantom dose distribution a special head phantom has been constructed and foil activation techniques and TLD700 dosimeter have been used. The results show that there is enough uniformity in TRR thermal BNCT beam. TG parameter has the maximum value of 5.7 at the depth of 1 cm from the surface of the phantom, confirming that TRR thermal neutron beam has potential for being used in treatment of superficial brain tumors. For the purpose of a clinical trial, more modifications need to be done at the reactor, as, for example design, and construction of a treatment room at the beam exit which is our plan for future. To date, this beam is usable for biological studies and animal trials. There is a relatively good agreement between simulation and measurement especially within a diameter of 10 cm which is the dimension of usual BNCT beam ports. This relatively good agreement enables a more precise prediction of the irradiation conditions needed for future experiments.

  11. A novel method for simultaneous measurement of doped optical fiber parameters

    NASA Astrophysics Data System (ADS)

    Karimi, M.; Seraji, F. E.

    2010-05-01

    Simultaneous measurement technique of evaluating the doped optical fibers (DOF) parameters is a suitable scheme for DOF production industries. In this paper, we introduce a novel technique to characterize simultaneously the main parameters of DOF such as absorption and emission cross-sections (ACS, ECS), background loss coefficient (BLC), and low dopant concentration using the gain equation of DOFs. We used this new method to determine the ACS, ECS, BLC in a standard sample of Al-P-Erbium doped optical fiber. The results have been analyzed and compared with other reports.

  12. Influence of physical parameters on radiation protection and image quality in intra-oral radiology

    NASA Astrophysics Data System (ADS)

    Belinato, W.; Souza, D. N.

    2011-10-01

    In the world of diagnostic imaging, radiography is an important supplementary method for dental diagnosis. In radiology, special attention must be paid to the radiological protection of patients and health professionals, and also to image quality for correct diagnosis. In Brazil, the national rules governing the operation of medical and dental radiology were specified in 1998 by the National Sanitary Surveillance Agency, complemented in 2005 by the guide "Medical radiology: security and performance of equipment." In this study, quality control tests were performed in public clinics with dental X-ray equipment in the State of Sergipe, Brazil, with consideration of the physical parameters that influence radiological protection and also the quality of images taken in intra-oral radiography. The accuracy of the exposure time was considered acceptable for equipment with digital timers. Exposure times and focal-spot size variations can lead to increased entrance dose. Increased dose has also been associated with visual processing of radiographic film, which often requires repeating the radiographic examination.

  13. Clinical quality is independently associated with favorable bond ratings.

    PubMed

    Haydar, Ziad; Nicewander, David; Convery, Paul; Black, Michael; Ballard, David

    2010-01-01

    The relation between clinical quality and bond rating for nonprofit hospitals has been proposed but never fully studied. We analyzed the relation between bond rating, clinical quality measures (The Joint Commission/Centers for Medicare and Medicaid Services [CMS] core measures), and balance sheet and income statement financial measures of 236 hospitals across the United States that are rated by Moody's Investors Service and that reported clinical quality measures to CMS during the study period. We found a statistically significant relation between higher quality measures and more favorable bond ratings. This association remained significant after controlling for traditional financial parameters.

  14. Local Neutral Density and Plasma Parameter Measurements in a Hollow Cathode Plume

    NASA Technical Reports Server (NTRS)

    Jameson, Kristina K.; Goebel, Dan M.; MiKellides, Joannis; Watkins, Ron M.

    2006-01-01

    In order to understand the cathode and keeper wear observed during the Extended Life Test (ELT) of the DS1 flight spare NSTAR thruster and provide benchmarking data for a 2D cathode/cathode-plume model, a basic understanding of the plasma and neutral gas parameters in the cathode orifice and keeper region of the cathode plume must be obtained. The JPL cathode facility is instrumented with an array of Langmuir probe diagnostics along with an optical diagnostic to measure line intensity of xenon neutrals. In order to make direct comparisons with the present model, a flat plate anode arrangement was installed for these tests. Neutral density is deduced from the scanning probe data of the plasma parameters and the measured xenon line intensity in the optical regime. The Langmuir probes are scanned both axially, out to 7.0 cm downstream of the keeper, and radially to obtain 2D profile of the plasma parameters. The optical fiber is housed in a collimating stainless steel tube, and is scanned to view across the cathode plume along cuts in front of the keeper with a resolution of 1.5 mm. The radial intensities are unfolded using the Abel inversion technique that produces radial profiles of local neutral density. In this paper, detailed measurements of the plasma parameters and the local neutral densities will be presented in the cathode/keeper plume region for a 1.5 cm diameter NEXIS cathode at 25A of discharge current at several different strengths of applied magnetic field.

  15. Determining the accuracy of maximum likelihood parameter estimates with colored residuals

    NASA Technical Reports Server (NTRS)

    Morelli, Eugene A.; Klein, Vladislav

    1994-01-01

    An important part of building high fidelity mathematical models based on measured data is calculating the accuracy associated with statistical estimates of the model parameters. Indeed, without some idea of the accuracy of parameter estimates, the estimates themselves have limited value. In this work, an expression based on theoretical analysis was developed to properly compute parameter accuracy measures for maximum likelihood estimates with colored residuals. This result is important because experience from the analysis of measured data reveals that the residuals from maximum likelihood estimation are almost always colored. The calculations involved can be appended to conventional maximum likelihood estimation algorithms. Simulated data runs were used to show that the parameter accuracy measures computed with this technique accurately reflect the quality of the parameter estimates from maximum likelihood estimation without the need for analysis of the output residuals in the frequency domain or heuristically determined multiplication factors. The result is general, although the application studied here is maximum likelihood estimation of aerodynamic model parameters from flight test data.

  16. Improved quantification of important beer quality parameters based on nonlinear calibration methods applied to FT-MIR spectra.

    PubMed

    Cernuda, Carlos; Lughofer, Edwin; Klein, Helmut; Forster, Clemens; Pawliczek, Marcin; Brandstetter, Markus

    2017-01-01

    During the production process of beer, it is of utmost importance to guarantee a high consistency of the beer quality. For instance, the bitterness is an essential quality parameter which has to be controlled within the specifications at the beginning of the production process in the unfermented beer (wort) as well as in final products such as beer and beer mix beverages. Nowadays, analytical techniques for quality control in beer production are mainly based on manual supervision, i.e., samples are taken from the process and analyzed in the laboratory. This typically requires significant lab technicians efforts for only a small fraction of samples to be analyzed, which leads to significant costs for beer breweries and companies. Fourier transform mid-infrared (FT-MIR) spectroscopy was used in combination with nonlinear multivariate calibration techniques to overcome (i) the time consuming off-line analyses in beer production and (ii) already known limitations of standard linear chemometric methods, like partial least squares (PLS), for important quality parameters Speers et al. (J I Brewing. 2003;109(3):229-235), Zhang et al. (J I Brewing. 2012;118(4):361-367) such as bitterness, citric acid, total acids, free amino nitrogen, final attenuation, or foam stability. The calibration models are established with enhanced nonlinear techniques based (i) on a new piece-wise linear version of PLS by employing fuzzy rules for local partitioning the latent variable space and (ii) on extensions of support vector regression variants (-PLSSVR and ν-PLSSVR), for overcoming high computation times in high-dimensional problems and time-intensive and inappropriate settings of the kernel parameters. Furthermore, we introduce a new model selection scheme based on bagged ensembles in order to improve robustness and thus predictive quality of the final models. The approaches are tested on real-world calibration data sets for wort and beer mix beverages, and successfully compared to

  17. Measuring the Multifaceted Nature of Infant and Toddler Care Quality

    ERIC Educational Resources Information Center

    Mangione, Peter L.; Kriener-Althen, Kerry; Marcella, Jennifer

    2016-01-01

    Research Findings: The quality of group care infants and toddlers experience relates to their concurrent and later development. Recent quality improvement initiatives point to the need for ecologically valid measures that assess the multifaceted nature of child care quality. In this article, we present the psychometric properties of an infant and…

  18. Effects of filtration through Sephadex columns improve overall quality parameters and "in vivo" fertility of subfertile refrigerated boar-semen.

    PubMed

    Ramió-Lluch, L; Balasch, S; Bonet, S; Briz, M; Pinart, E; Rodríguez-Gil, J E

    2009-10-01

    This study was performed to test the effects of filtration through several chromatographic resins on the semen quality parameters (percentages of viability, altered acrosomes and morphological abnormalities, motion characteristics and the response to the Osmotic Resistance Test) of boar ejaculates of poor quality. Our results indicate that filtration through a non-ionic Sephadex resin bed (Sephadex G-15), combined with a glasswool subjection bed, induced an overall improvement of semen quality parameters, especially seen in a significant (P<0.05) decrease in the percentages of morphological abnormalities and an increase of several motility parameters related to velocity and linearity. Similar results, although less intense, were observed when the filtration through G-15 resin was accompanied by an ionically neutral polypropylene disk bed instead of glasswool. On the other hand, filtration through two separate ion-exchange Sephadex resins, cationic C-50 and anionic A-50, have less beneficial, and even detrimental, effects on boar-semen quality. In all cases, filtration was accompanied by a significant (P<0.01) decrease in the final concentration of the samples. Ultrastructural and lectin studies showed that the interaction between sperm and chromatographic resins depends on the resin type utilized, and in the case of G-15 it seems that it works by trapping that sperm with not enough strength to overcome the physical resistance associated with chromatographic particles. When semen of poor quality was filtered through G-15 resin and then was utilized for "in vivo" fertility trials, a significant (P<0.05) increase in the percentage of fertility was observed, when compared with the same, but unfiltered, samples. In summary, our results strongly indicate that filtration through ionically inert, Sephadex chromatographic resins could be a very useful and practical method to improve both boar-semen quality and fertilizing ability, especially from mediocre and/or subfertile

  19. Translation, cultural adaptation, cross-validation of the Turkish diabetes quality-of-life (DQOL) measure.

    PubMed

    Yildirim, Aysegul; Akinci, Fevzi; Gozu, Hulya; Sargin, Haluk; Orbay, Ekrem; Sargin, Mehmet

    2007-06-01

    The aim of this study was to test the validity and reliability of the Turkish version of the diabetes quality of life (DQOL) questionnaire for use with patients with diabetes. Turkish version of the generic quality of life (QoL) scale 15D and DQOL, socio-demographics and clinical parameter characteristics were administered to 150 patients with type 2 diabetes. Study participants were randomly sampled from the Endocrinology and Diabetes Outpatient Department of Dr. Lutfi Kirdar Kartal Education and Research Hospital in Istanbul, Turkey. The Cronbach alpha coefficient of the overall DQOL scale was 0.89; the Cronbach alpha coefficient ranged from 0.80 to 0.94 for subscales. Distress, discomfort and its symptoms, depression, mobility, usual activities, and vitality on the 15 D scale had statistically significant correlations with social/vocational worry and diabetes-related worry on the DQOL scale indicating good convergent validity. Factor analysis identified four subscales: satisfaction", impact", "diabetes-related worry", and "social/vocational worry". Statistical analyses showed that the Turkish version of the DQOL is a valid and reliable instrument to measure disease related QoL in patients with diabetes. It is a simple and quick screening tool with about 15 +/- 5.8 min administration time for measuring QoL in this population.

  20. Clustering of reads with alignment-free measures and quality values.

    PubMed

    Comin, Matteo; Leoni, Andrea; Schimd, Michele

    2015-01-01

    The data volume generated by Next-Generation Sequencing (NGS) technologies is growing at a pace that is now challenging the storage and data processing capacities of modern computer systems. In this context an important aspect is the reduction of data complexity by collapsing redundant reads in a single cluster to improve the run time, memory requirements, and quality of post-processing steps like assembly and error correction. Several alignment-free measures, based on k-mers counts, have been used to cluster reads. Quality scores produced by NGS platforms are fundamental for various analysis of NGS data like reads mapping and error detection. Moreover future-generation sequencing platforms will produce long reads but with a large number of erroneous bases (up to 15 %). In this scenario it will be fundamental to exploit quality value information within the alignment-free framework. To the best of our knowledge this is the first study that incorporates quality value information and k-mers counts, in the context of alignment-free measures, for the comparison of reads data. Based on this principles, in this paper we present a family of alignment-free measures called D (q) -type. A set of experiments on simulated and real reads data confirms that the new measures are superior to other classical alignment-free statistics, especially when erroneous reads are considered. Also results on de novo assembly and metagenomic reads classification show that the introduction of quality values improves over standard alignment-free measures. These statistics are implemented in a software called QCluster (http://www.dei.unipd.it/~ciompin/main/qcluster.html).

  1. Urban air quality measurements using a sensor-based system

    NASA Astrophysics Data System (ADS)

    Ródenas, Mila; Hernández, Daniel; Gómez, Tatiana; López, Ramón; Muñoz, Amalia

    2017-04-01

    Air pollution levels in urban areas have increased the interest, not only of the scientific community but also of the general public, and both at the regional and at the European level. This interest has run in parallel to the development of miniaturized sensors, which only since very recently are suitable for air quality measurements. Certainly, their small size and price allows them to be used as a network of sensors capable of providing high temporal and spatial frequency measurements to characterize an area or city and with increasing potential, under certain considerations, as a complement of conventional methods. Within the frame of the LIFE PHOTOCITYTEX project (use of photocatalytic textiles to help reducing air pollution), CEAM has developed a system to measure gaseous compounds of importance for urban air quality characterization. This system, which allows an autonomous power supply, uses commercial NO, NO2, O3 and CO2 small sensors and incorporates measurements of temperature and humidity. A first version, using XBee boards (Radiofrequency) for communications has been installed in the urban locations defined by the project (tunnel and school), permitting the long-term air quality characterization of sites in the presence of the textiles. An improved second version of the system which also comprises a sensor for measuring particles and which uses GPRS for communications, has been developed and successfully installed in the city center of Valencia. Data are sent to a central server where they can be accessed by citizens in nearly real time and online and, in general, they can be utilized in the air quality characterization, for decision-making related to decontamination (traffic regulation, photocatalytic materials, etc.), in air quality models or in mobile applications of interest for the citizens. Within this work, temporal trends obtained with this system in different urban locations will be shown, discussing the impact of the characteristics of the

  2. Impact of the present-on-admission indicator on hospital quality measurement: experience with the Agency for Healthcare Research and Quality (AHRQ) Inpatient Quality Indicators.

    PubMed

    Glance, Laurent G; Osler, Turner M; Mukamel, Dana B; Dick, Andrew W

    2008-02-01

    The Agency for Healthcare Research and Quality (AHRQ) has constructed Inpatient Quality Indicator (IQI) mortality measures to measure hospital quality using routinely available administrative data. With the exception of California, New York State, and Wisconsin, administrative data do not include a present-on-admission (POA) indicator to distinguish between preexisting conditions and complications. The extent to which the lack of a POA indicator biases quality assessment based on the AHRQ mortality measures is unknown. To examine the impact of the POA indicator on hospital quality assessment based on the AHRQ mortality measures using enhanced administrative data from California, which includes a POA indicator. Retrospective cohort study based on 2.07 million inpatient admissions between 1998 and 2000 in the California State Inpatient Database. The AHRQ IQI software was used to calculate risk-adjusted mortality rates using either (1) routine administrative data that included all the International Classification of Diseases (ICD)-9-CM codes or (2) enhanced administrative data that included only the ICD-9-CM codes representing preexisting conditions. The inclusion of the POA indicator frequently results in changes in the quality ranking of hospitals classified as high-quality or low-quality using routine administrative data. Twenty-seven percent (stroke) to 94% (coronary artery bypass graft) of hospitals classified as high-quality using routine administrative data were reclassified as intermediate- or low-quality hospitals using the enhanced administrative data. Twenty-five percent (congestive heart failure) to 76% (percutaneous coronary intervention) of hospitals classified as low-quality hospitals using enhanced administrative data were misclassified as intermediate-quality hospitals using routine administrative data. Despite the fact that the AHRQ IQIs were primarily intended to serve as a screening tool, they are being increasingly used to publicly report hospital

  3. Quantification of Water Quality Parameters for the Wabash River Using Hyperspectral Remote Sensing

    NASA Astrophysics Data System (ADS)

    Tan, J.; Cherkauer, K. A.; Chaubey, I.

    2011-12-01

    Increasingly impaired water bodies in the agriculturally dominated Midwestern United States pose a risk to water supplies, aquatic ecology and contribute to the eutrophication of the Gulf of Mexico. Improving regional water quality calls for new techniques for monitoring and managing water quality over large river systems. Optical indicators of water quality enable a timely and cost-effective method for observing and quantifying water quality conditions by remote sensing. Compared to broad spectral sensors such as Landsat, which observe reflectance over limited spectral bands, hyperspectral sensors should have significant advantages in their ability to estimate water quality parameters because they are designed to split the spectral signature into hundreds of very narrow spectral bands increasing their ability to resolve optically sensitive water quality indicators. Two airborne hyperspectral images were acquired over the Wabash River using a ProSpecTIR-VS2 sensor system on May 15th, 2010. These images were analyzed together with concurrent in-stream water quality data collected to assess our ability to extract optically sensitive constituents. Utilizing the correlation between in-stream data and reflectance from the hyperspectral images, models were developed to estimate the concentrations of chlorophyll a, dissolved organic carbon and total suspended solids. Models were developed using the full array of hyperspectral bands, as well as Landsat bands synthesized by averaging hyperspectral bands within the Landsat spectral range. Higher R2 and lower RMSE values were found for the models taking full advantage of the hyperspectral sensor, supporting the conclusion that the hyperspectral sensor was better at predicting the in-stream concentrations of chlorophyll a, dissolved organic carbon and total suspended solids in the Wabash River. Results also suggest that predictive models may not be the same for the Wabash River as for its tributaries.

  4. Measuring Teaching Quality in Several European Countries

    ERIC Educational Resources Information Center

    van de Grift, Wim J. C. M.

    2014-01-01

    Teaching quality has been observed in large representative samples from Flanders (Belgium), Lower Saxony (Germany), the Slovak Republic, and The Netherlands. This study reveals that measures of "creating a safe and stimulating climate", "clear and activating instruction", and "teaching learning strategies" were…

  5. Overview: Measuring Early Learning Quality and Outcomes (MELQO)

    ERIC Educational Resources Information Center

    Brookings Institution, 2017

    2017-01-01

    The Measuring Early Learning Quality and Outcomes (MELQO) initiative began in 2014 in anticipation of a new global emphasis on early childhood development (ECD). Led by UNESCO, the World Bank, the Center for Universal Education at the Brookings Institution, and UNICEF, the initiative aims to promote feasible, accurate and useful measurement of…

  6. Measurement properties of adult quality-of-life measurement instruments for eczema: protocol for a systematic review.

    PubMed

    Apfelbacher, Christian J; Heinl, Daniel; Prinsen, Cecilia A C; Deckert, Stefanie; Chalmers, Joanne; Ofenloch, Robert; Humphreys, Rosemary; Sach, Tracey; Chamlin, Sarah; Schmitt, Jochen

    2015-04-16

    Eczema is a common chronic or chronically relapsing skin disease that has a substantial impact on quality of life (QoL). By means of a consensus-based process, the Harmonising Outcome Measures in Eczema (HOME) initiative has identified QoL as one of the four core outcome domains to be assessed in all eczema trials (Allergy 67(9):1111-7, 2012). Various measurement instruments exist to measure QoL in adults with eczema, but there is a great variability in both content and quality (for example, reliability and validity) of the instruments used, and it is not always clear if the best instrument is being used. Therefore, the aim of the proposed research is a comprehensive systematic assessment of the measurement properties of the existing measurement instruments that were developed and/or validated for the measurement of patient-reported QoL in adults with eczema. This study is a systematic review of the measurement properties of patient-reported measures of QoL developed and/or validated for adults with eczema. Medline via PubMed and EMBASE will be searched using a selection of relevant search terms. Eligible studies will be primary empirical studies evaluating, describing, or comparing measurement properties of QoL instruments for adult patients with eczema. Eligibility assessment and data abstraction will be performed independently by two reviewers. Evidence tables will be generated for study characteristics, instrument characteristics, measurement properties, and interpretability. The quality of the measurement properties will be assessed using predefined criteria. Methodological quality of studies will be assessed using the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist. A best evidence synthesis will be undertaken if more than one study has investigated a particular measurement property. The proposed systematic review will produce a comprehensive assessment of measurement properties of existing QoL instruments in

  7. Implementation of Quality Assurance and Quality Control Measures in the National Phenology Database

    NASA Astrophysics Data System (ADS)

    Gerst, K.; Rosemartin, A.; Denny, E. G.; Marsh, L.; Barnett, L.

    2015-12-01

    The USA National Phenology Network (USA-NPN; www.usanpn.org) serves science and society by promoting a broad understanding of plant and animal phenology and the relationships among phenological patterns and environmental change. The National Phenology Database has over 5.5 million observation records for plants and animals for the period 1954-2015. These data have been used in a number of science, conservation and resource management applications, including national assessments of historical and potential future trends in phenology, regional assessments of spatio-temporal variation in organismal activity, and local monitoring for invasive species detection. Customizable data downloads are freely available, and data are accompanied by FGDC-compliant metadata, data-use and data-attribution policies, and vetted documented methodologies and protocols. The USA-NPN has implemented a number of measures to ensure both quality assurance and quality control. Here we describe the resources that have been developed so that incoming data submitted by both citizen and professional scientists are reliable; these include training materials, such as a botanical primer and species profiles. We also describe a number of automated quality control processes applied to incoming data streams to optimize data output quality. Existing and planned quality control measures for output of raw and derived data include: (1) Validation of site locations, including latitude, longitude, and elevation; (2) Flagging of records that conflict for a given date for an individual plant; (3) Flagging where species occur outside known ranges; (4) Flagging of records when phenophases occur outside of the plausible order for a species; (5) Flagging of records when intensity measures do not follow a plausible progression for a phenophase; (6) Flagging of records when a phenophase occurs outside of the plausible season, and (7) Quantification of precision and uncertainty for estimation of phenological metrics

  8. Measurement equivalence of the newly developed Quality of Life in Childhood Epilepsy Questionnaire (QOLCE-55).

    PubMed

    Ferro, Mark A; Goodwin, Shane W; Sabaz, Mark; Speechley, Kathy N

    2016-03-01

    The aim of this study was to examine measurement equivalence of the newly developed Quality of Life in Childhood Epilepsy Questionnaire (QOLCE-55) across age, sex, and time in a representative sample of children with newly diagnosed epilepsy. Data come from 373 children enrolled in the Health-related Quality of Life in Children with Epilepsy Study (HERQULES), a multisite prospective cohort study. Measurement equivalence was examined using a multiple-group confirmatory factor analysis framework, whereby increasingly stringent parameter constraints are imposed on the model. Comparison groups were stratified based on age (4-7 years vs. 8-12 years), sex (male vs. female), and time (measurement of health-related quality of life at diagnosis vs. 24 months later). The QOLCE-55 demonstrated measurement equivalence at the level of strict invariance for each model tested--age: χ(2) (3,123) = 4,097.3, p < 0.001; Comparative Fit Index (CFI) = 0.968; Root Mean Square Error of Approximation (RMSEA) = 0.042 (0.038, 0.045); sex: χ(2) (3,124) = 4,188.3, p < 0.001; CFI = 0.964; RMSEA = 0.044 (0.040, 0.047); and time: χ(2) (3,121) = 5,185.0, p < 0.001; CFI = 0.965; RMSEA = 0.046 (0.043, 0.048). These findings suggest that items comprising the QOLCE-55 are perceived similarly among groups stratified by age, sex, and time and provide further evidence supporting the validity of the scale in children with epilepsy. Health professionals and researchers should be confident that group comparisons made using the QOLCE-55 are unbiased and that any group differences detected are meaningful; that is, not related to differences in the interpretation of items by informants. Future research replicating these findings is encouraged. Wiley Periodicals, Inc. © 2016 International League Against Epilepsy.

  9. Air quality measurements-From rubber bands to tapping the rainbow.

    PubMed

    Hidy, George M; Mueller, Peter K; Altshuler, Samuel L; Chow, Judith C; Watson, John G

    2017-06-01

    It is axiomatic that good measurements are integral to good public policy for environmental protection. The generalized term for "measurements" includes sampling and quantitation, data integrity, documentation, network design, sponsorship, operations, archiving, and accessing for applications. Each of these components has evolved and advanced over the last 200 years as knowledge of atmospheric chemistry and physics has matured. Air quality was first detected by what people could see and smell in contaminated air. Gaseous pollutants were found to react with certain materials or chemicals, changing the color of dissolved reagents such that their light absorption at selected wavelengths could be related to both the pollutant chemistry and its concentration. Airborne particles have challenged the development of a variety of sensory devices and laboratory assays for characterization of their enormous range of physical and chemical properties. Advanced electronics made possible the sampling, concentration, and detection of gases and particles, both in situ and in laboratory analysis of collected samples. Accurate and precise measurements by these methods have made possible advanced air quality management practices that led to decreasing concentrations over time. New technologies are leading to smaller and cheaper measurement systems that can further expand and enhance current air pollution monitoring networks. Ambient air quality measurement systems have a large influence on air quality management by determining compliance, tracking trends, elucidating pollutant transport and transformation, and relating concentrations to adverse effects. These systems consist of more than just instrumentation, and involve extensive support efforts for siting, maintenance, calibration, auditing, data validation, data management and access, and data interpretation. These requirements have largely been attained for criteria pollutants regulated by National Ambient Air Quality Standards

  10. Influence of camera parameters on the quality of mobile 3D capture

    NASA Astrophysics Data System (ADS)

    Georgiev, Mihail; Boev, Atanas; Gotchev, Atanas; Hannuksela, Miska

    2010-01-01

    We investigate the effect of camera de-calibration on the quality of depth estimation. Dense depth map is a format particularly suitable for mobile 3D capture (scalable and screen independent). However, in real-world scenario cameras might move (vibrations, temp. bend) form their designated positions. For experiments, we create a test framework, described in the paper. We investigate how mechanical changes will affect different (4) stereo-matching algorithms. We also assess how different geometric corrections (none, motion compensation-like, full rectification) will affect the estimation quality (how much offset can be still compensated with "crop" over a larger CCD). Finally, we show how estimated camera pose change (E) relates with stereo-matching, which can be used for "rectification quality" measure.

  11. [Inter-and intra-operator variability in the analysis of semen parameters: results from a quality control program].

    PubMed

    Daoud, Salima; Chakroun-Feki, Nozha; Sellami, Afifa; Ammar-Keskes, Leila; Rebai, Tarek

    2016-01-01

    Semen analysis is a key part of male infertility investigation. The necessity of quality management implementation in the andrology laboratory has been recognized in order to ensure the reliability of its results. The aim of this study was to evaluate intra- and inter-individual variability in the assessment of semen parameters in our laboratory through a quality control programme. Four participants from the laboratory with different experience levels have participated in this study. Semen samples of varying quality were assessed for sperm motility, concentration and morphology and the results were used to evaluate inter-participant variability. In addition, replicates of each semen sample were analyzed to determine intra-individual variability for semen parameters analysis. The average values of inter-participant coefficients of variation for sperm motility, concentration and morphology were 12.8%, 19.8% and 48.9% respectively. The mean intra-participant coefficients of variation were, respectively, 6.9%, 12.3% and 42.7% for sperm motility, concentration and morphology. Despite some random errors of under- or overestimation, the overall results remained within the limits of acceptability for all participants. Sperm morphology assessment was particularly influenced by the participant's level of experience. The present data emphasize the need for appropriate training of the laboratory staff and for regular participation in internal quality control programmes in order to improve the reliability of laboratory results.

  12. Genetic parameters of product quality and hepatic metabolism in fattened mule ducks.

    PubMed

    Marie-Etancelin, C; Basso, B; Davail, S; Gontier, K; Fernandez, X; Vitezica, Z G; Bastianelli, D; Baéza, E; Bernadet, M-D; Guy, G; Brun, J-M; Legarra, A

    2011-03-01

    Genetic parameters of traits related to hepatic lipid metabolism, carcass composition, and product quality of overfed mule ducks were estimated on both parental lines of this hybrid: the common duck line for the maternal side and the Muscovy line for the paternal side. The originality of the statistical model was to include simultaneously the additive genetic effect of the common ducks and that of the Muscovy ducks, revealing a greater genetic determinism in common than in Muscovy. Plasma metabolic indicators (glucose, triglyceride, and cholesterol contents) were heritable, in particular at the end of the overfeeding period, and heritabilities increased with the overfeeding stage. Carcass composition traits were highly heritable in the common line, with values ranging from 0.15 for liver weight, 0.21 for carcass weight, and 0.25 for abdominal fat weight to 0.32 for breast muscle weight. Heritabilities of technological outputs were greater for the fatty liver (0.19 and 0.08, respectively, on common and Muscovy sides for liver melting rate) than for the pectoralis major muscle (between 0.02 and 0.05 on both parental sides for cooking losses). Fortunately, the processing industry is mainly facing problems in liver quality, such as too high of a melting rate, than in meat quality. The meat quality appraisal criteria (such as texture and cooking losses), usually dependent on pH and the rate of decline of pH, were also very lowly heritable. This study demonstrated that genetic determinism of meat quality and ability of overfeeding is not similar in the common population and in the Muscovy population; traits related to fattening, muscle development, and BW have heritability values from 2 to 4 times greater on the common line than on the Muscovy line, which is relevant for considering different selection strategies.

  13. Bayesian Parameter Estimation for Heavy-Duty Vehicles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, Eric; Konan, Arnaud; Duran, Adam

    2017-03-28

    Accurate vehicle parameters are valuable for design, modeling, and reporting. Estimating vehicle parameters can be a very time-consuming process requiring tightly-controlled experimentation. This work describes a method to estimate vehicle parameters such as mass, coefficient of drag/frontal area, and rolling resistance using data logged during standard vehicle operation. The method uses Monte Carlo to generate parameter sets which is fed to a variant of the road load equation. Modeled road load is then compared to measured load to evaluate the probability of the parameter set. Acceptance of a proposed parameter set is determined using the probability ratio to the currentmore » state, so that the chain history will give a distribution of parameter sets. Compared to a single value, a distribution of possible values provides information on the quality of estimates and the range of possible parameter values. The method is demonstrated by estimating dynamometer parameters. Results confirm the method's ability to estimate reasonable parameter sets, and indicates an opportunity to increase the certainty of estimates through careful selection or generation of the test drive cycle.« less

  14. Navigating in the turbulent sea of data: the quality measurement journey.

    PubMed

    Lloyd, Robert C

    2010-03-01

    This article provides a roadmap for your quality measurement journey. It begins with a discussion of 3 approaches to measurement (improvement, accountability and research) and challenges readers to be clear about why they are measuring. Key milestones along the quality measurement journey are then presented and a framework for selecting measures, developing clear operational definitions, building data collection plans, and understanding the variation that exists in data is outlined. The article ends with a discussion of why data need to be linked to improvement strategies. Copyright 2010 Elsevier Inc. All rights reserved.

  15. A PROMIS Measure of Neuropathic Pain Quality

    PubMed Central

    Askew, Robert L.; Cook, Karon F.; Keefe, Francis J.; Nowinski, Cindy J; Cella, David; Revicki, Dennis A.; DeWitt, Esi M. Morgan; Michaud, Kaleb; Trence, Dace L.; Amtmann, Dagmar

    2016-01-01

    Objectives Neuropathic pain is a consequence of many chronic conditions. This study aimed to develop a unidimensional neuropathic pain scale whose scores represent levels of neuropathic pain and distinguish between individuals with neuropathic and non-neuropathic pain conditions. Methods A candidate item pool of 42 pain quality descriptors was administered to participants with osteoarthritis, rheumatoid arthritis, diabetic neuropathy, and cancer chemotherapy-induced peripheral neuropathy. A subset of pain quality descriptors (items) that best distinguished between participants with and those without neuropathic pain conditions were identified. Dimensionality of pain descriptors was evaluated in a development sample and cross-validated in a hold-out sample. Item responses were calibrated using an item response theory model, and scores were generated on a T-score metric. Neuropathic pain scale scores were evaluated in terms of reliability, validity, and the ability to distinguish between participants with and without conditions typically associated with neuropathic pain. Results Of the 42 initial items, 5 were identified for the Patient Reported Outcome Measurement Information System (PROMIS) Neuropathic Pain Quality scale (PROMIS-PQ-Neuro). The IRT-generated T-scores exhibited good discriminatory ability based on receiver operator characteristic analysis. Score thresholds were identified that optimize sensitivity and specificity. Construct, criterion, and discriminant validity, and reliability of scale scores were supported. Conclusions The 5-item PROMIS PQ-Neuro is a short and practical measure that can be used to identify patients more likely to have neuropathic pain and to distinguish levels of neuropathic pain. The data collected will support future research that targets other unidimensional pain quality domains (e.g., nociceptive pain). PMID:27565279

  16. Measures and Indicators of Vgi Quality: AN Overview

    NASA Astrophysics Data System (ADS)

    Antoniou, V.; Skopeliti, A.

    2015-08-01

    The evaluation of VGI quality has been a very interesting and popular issue amongst academics and researchers. Various metrics and indicators have been proposed for evaluating VGI quality elements. Various efforts have focused on the use of well-established methodologies for the evaluation of VGI quality elements against authoritative data. In this paper, a number of research papers have been reviewed and summarized in a detailed report on measures for each spatial data quality element. Emphasis is given on the methodology followed and the data used in order to assess and evaluate the quality of the VGI datasets. However, as the use of authoritative data is not always possible many researchers have turned their focus on the analysis of new quality indicators that can function as proxies for the understanding of VGI quality. In this paper, the difficulties in using authoritative datasets are briefly presented and new proposed quality indicators are discussed, as recorded through the literature review. We classify theses new indicators in four main categories that relate with: i) data, ii) demographics, iii) socio-economic situation and iv) contributors. This paper presents a dense, yet comprehensive overview of the research on this field and provides the basis for the ongoing academic effort to create a practical quality evaluation method through the use of appropriate quality indicators.

  17. Evaluation of ultrasound based sterilization approaches in terms of shelf life and quality parameters of fruit and vegetable juices.

    PubMed

    Khandpur, Paramjeet; Gogate, Parag R

    2016-03-01

    The present work evaluates the performance of ultrasound based sterilization approaches for processing of different fruit and vegetable juices in terms of microbial growth and changes in the quality parameters during the storage. Comparison with the conventional thermal processing has also been presented. A novel approach based on combination of ultrasound with ultraviolet irradiation and crude extract of essential oil from orange peels has been used for the first time. Identification of the microbial growth (total bacteria and yeast content) in the juices during the subsequent storage and assessing the safety for human consumption along with the changes in the quality parameters (Brix, titratable acidity, pH, ORP, salt, conductivity, TSS and TDS) has been investigated in details. The optimized ultrasound parameters for juice sterilization were established as ultrasound power of 100 W and treatment time of 15 min for the constant frequency operation (20 kHz). It has been established that more than 5 log reduction was achieved using the novel combined approaches based on ultrasound. The treated juices using different approaches based on ultrasound also showed lower microbial growth and improved quality characteristics as compared to the thermally processed juice. Scale up studies were also performed using spinach juice as the test sample with processing at 5 L volume for the first time. The ultrasound treated juice satisfied the microbiological and physiochemical safety limits in refrigerated storage conditions for 20 days for the large scale processing. Overall the present work conclusively established the usefulness of combined treatment approaches based on ultrasound for maintaining the microbiological safety of beverages with enhanced shelf life and excellent quality parameters as compared to the untreated and thermally processed juices. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Crowding measures associated with the quality of emergency department care: a systematic review.

    PubMed

    Stang, Antonia S; Crotts, Jennifer; Johnson, David W; Hartling, Lisa; Guttmann, Astrid

    2015-06-01

    Despite the substantial body of literature on emergency department (ED) crowding, to the best of our knowledge, there is no agreement on the measure or measures that should be used to quantify crowding. The objective of this systematic review was to identify existing measures of ED crowding that have been linked to quality of care as defined by the Institute of Medicine (IOM) quality domains (safe, effective, patient-centered, efficient, timely, and equitable). Six major bibliographic databases were searched from January 1980 to January 2012, and hand searches were conducted of relevant journals and conference proceedings. Observational studies (cross-sectional, cohort, and case-control), quality improvement studies, quasi-experimental (e.g., before/after) studies, and randomized controlled trials were considered for inclusion. Studies that did not provide measures of ED crowding were excluded. Studies that did not provide quantitative data on the link between crowding measures and quality of care were also excluded. Two independent reviewers assessed study eligibility, completed data extraction, and assessed study quality using the Newcastle-Ottawa Quality Assessment Scale (NOS) for observational studies and a modified version of the NOS for cross-sectional studies. The search identified 7,413 articles. Thirty-two articles were included in the review: six cross-sectional, one case-control, 23 cohort, and two retrospective reviews of performance improvement data. Methodologic quality was moderate, with weaknesses in the reporting of study design and methodology. Overall, 15 of the crowding measures studied had quantifiable links to quality of care. The three measures most frequently linked to quality of care were the number of patients in the waiting room, ED occupancy (percentage of overall ED beds filled), and the number of admitted patients in the ED awaiting inpatient beds. None of the articles provided data on the link between crowding measures and the IOM

  19. GROUND WATER QUALITY SURROUNDING LAKE TEXOMA DURING DROUGHT CONDITIONS

    EPA Science Inventory

    Water quality data from 55 producing monitoring wells during drought conditions surrounding Lake Texoma, located on the border of Oklahoma and Texas, was compared to assess the influence of drought on groundwater quality. The main water quality parameter measured was nitrate, an...

  20. Analysis and detection of functional outliers in water quality parameters from different automated monitoring stations in the Nalón river basin (Northern Spain).

    PubMed

    Piñeiro Di Blasi, J I; Martínez Torres, J; García Nieto, P J; Alonso Fernández, J R; Díaz Muñiz, C; Taboada, J

    2015-01-01

    The purposes and intent of the authorities in establishing water quality standards are to provide enhancement of water quality and prevention of pollution to protect the public health or welfare in accordance with the public interest for drinking water supplies, conservation of fish, wildlife and other beneficial aquatic life, and agricultural, industrial, recreational, and other reasonable and necessary uses as well as to maintain and improve the biological integrity of the waters. In this way, water quality controls involve a large number of variables and observations, often subject to some outliers. An outlier is an observation that is numerically distant from the rest of the data or that appears to deviate markedly from other members of the sample in which it occurs. An interesting analysis is to find those observations that produce measurements that are different from the pattern established in the sample. Therefore, identification of atypical observations is an important concern in water quality monitoring and a difficult task because of the multivariate nature of water quality data. Our study provides a new method for detecting outliers in water quality monitoring parameters, using turbidity, conductivity and ammonium ion as indicator variables. Until now, methods were based on considering the different parameters as a vector whose components were their concentration values. This innovative approach lies in considering water quality monitoring over time as continuous curves instead of discrete points, that is to say, the dataset of the problem are considered as a time-dependent function and not as a set of discrete values in different time instants. This new methodology, which is based on the concept of functional depth, was applied to the detection of outliers in water quality monitoring samples in the Nalón river basin with success. Results of this study were discussed here in terms of origin, causes, etc. Finally, the conclusions as well as advantages of