Sample records for quality parameters parameters

  1. Proposed DoD (Department of Defense) Internet Protocol Standard.

    DTIC Science & Technology

    1982-07-06

    parameters fall into two categories: service quality parameters and service options. Service quality parameters influence the transmission service provided...Corporation 6 July 1982 -7- TM-7172/481/OO o Service Quality Parameters - Precedence : attempts preferential treatment for high importance datagrams...select the transmission quality. IP passes the type of service (TOS) command set for service quality to the SNP where it is mapped into subnetwork

  2. Use of ocean color scanner data in water quality mapping

    NASA Technical Reports Server (NTRS)

    Khorram, S.

    1981-01-01

    Remotely sensed data, in combination with in situ data, are used in assessing water quality parameters within the San Francisco Bay-Delta. The parameters include suspended solids, chlorophyll, and turbidity. Regression models are developed between each of the water quality parameter measurements and the Ocean Color Scanner (OCS) data. The models are then extended to the entire study area for mapping water quality parameters. The results include a series of color-coded maps, each pertaining to one of the water quality parameters, and the statistical analysis of the OCS data and regression models. It is found that concurrently collected OCS data and surface truth measurements are highly useful in mapping the selected water quality parameters and locating areas having relatively high biological activity. In addition, it is found to be virtually impossible, at least within this test site, to locate such areas on U-2 color and color-infrared photography.

  3. Learning the manifold of quality ultrasound acquisition.

    PubMed

    El-Zehiry, Noha; Yan, Michelle; Good, Sara; Fang, Tong; Zhou, S Kevin; Grady, Leo

    2013-01-01

    Ultrasound acquisition is a challenging task that requires simultaneous adjustment of several acquisition parameters (the depth, the focus, the frequency and its operation mode). If the acquisition parameters are not properly chosen, the resulting image will have a poor quality and will degrade the patient diagnosis and treatment workflow. Several hardware-based systems for autotuning the acquisition parameters have been previously proposed, but these solutions were largely abandoned because they failed to properly account for tissue inhomogeneity and other patient-specific characteristics. Consequently, in routine practice the clinician either uses population-based parameter presets or manually adjusts the acquisition parameters for each patient during the scan. In this paper, we revisit the problem of autotuning the acquisition parameters by taking a completely novel approach and producing a solution based on image analytics. Our solution is inspired by the autofocus capability of conventional digital cameras, but is significantly more challenging because the number of acquisition parameters is large and the determination of "good quality" images is more difficult to assess. Surprisingly, we show that the set of acquisition parameters which produce images that are favored by clinicians comprise a 1D manifold, allowing for a real-time optimization to maximize image quality. We demonstrate our method for acquisition parameter autotuning on several live patients, showing that our system can start with a poor initial set of parameters and automatically optimize the parameters to produce high quality images.

  4. Taguchi's off line method and Multivariate loss function approach for quality management and optimization of process parameters -A review

    NASA Astrophysics Data System (ADS)

    Bharti, P. K.; Khan, M. I.; Singh, Harbinder

    2010-10-01

    Off-line quality control is considered to be an effective approach to improve product quality at a relatively low cost. The Taguchi method is one of the conventional approaches for this purpose. Through this approach, engineers can determine a feasible combination of design parameters such that the variability of a product's response can be reduced and the mean is close to the desired target. The traditional Taguchi method was focused on ensuring good performance at the parameter design stage with one quality characteristic, but most products and processes have multiple quality characteristics. The optimal parameter design minimizes the total quality loss for multiple quality characteristics. Several studies have presented approaches addressing multiple quality characteristics. Most of these papers were concerned with maximizing the parameter combination of signal to noise (SN) ratios. The results reveal the advantages of this approach are that the optimal parameter design is the same as the traditional Taguchi method for the single quality characteristic; the optimal design maximizes the amount of reduction of total quality loss for multiple quality characteristics. This paper presents a literature review on solving multi-response problems in the Taguchi method and its successful implementation in various industries.

  5. Association between bibliometric parameters, reporting and methodological quality of randomised controlled trials in vascular and endovascular surgery.

    PubMed

    Hajibandeh, Shahab; Hajibandeh, Shahin; Antoniou, George A; Green, Patrick A; Maden, Michelle; Torella, Francesco

    2017-04-01

    Purpose We aimed to investigate association between bibliometric parameters, reporting and methodological quality of vascular and endovascular surgery randomised controlled trials. Methods The most recent 75 and oldest 75 randomised controlled trials published in leading journals over a 10-year period were identified. The reporting quality was analysed using the CONSORT statement, and methodological quality with the Intercollegiate Guidelines Network checklist. We used exploratory univariate and multivariable linear regression analysis to investigate associations. Findings Bibliometric parameters such as type of journal, study design reported in title, number of pages; external funding, industry sponsoring and number of citations are associated with reporting quality. Moreover, parameters such as type of journal, subject area and study design reported in title are associated with methodological quality. Conclusions The bibliometric parameters of randomised controlled trials may be independent predictors for their reporting and methodological quality. Moreover, the reporting quality of randomised controlled trials is associated with their methodological quality and vice versa.

  6. The effect of cryopreservation on goat semen characteristics related to sperm freezability.

    PubMed

    Dorado, J; Muñoz-Serrano, A; Hidalgo, M

    2010-08-01

    Seminal quality parameters were used to evaluate the effect of freeze-thawing procedure on goat sperm characteristics, and to relate possible changes in sperm parameters to cryopreservation success. Semen samples (n=110) were frozen with TRIS and milk-based extenders and thawed. Sperm quality parameters (motility, morphology and acrosome) were compared between fresh and frozen-thawed samples. Sperm freezability was judged by classifying the semen samples as "suitable" or "not suitable" according to the sperm quality parameters assessed before and after thawing. Fertility data was obtained after cervical insemination with frozen semen doses. The ejaculates were grouped into two categories according to their fertility results. In experiment 1, significant differences were found between semen extenders (P<0.001), bucks (P<0.05) and ejaculates within the same male (P<0.05) in terms of sperm quality. There was no seasonal effect (P>0.05) on the majority of the sperm parameters assessed after thawing. Moreover, significant differences (P<0.001) in semen parameters assessed in fresh semen and frozen-thawed samples were found between groups. The effect of the freeze-thawing procedure on sperm quality parameters was also different (P<0.05) between extenders within the same group. The number of sperm quality parameters that had changed after cryopreservation was lower in "suitable" semen samples before and after thawing. In experiment 2, no differences (P>0.05) in semen parameters assessed in fresh semen and frozen-thawed samples were found between groups. The effect of freezing and thawing on sperm quality parameters were different (P<0.05) between extenders within the same group. Only mean beat cross frequency (BCF) values were significantly higher (P<0.05) in TRIS diluted samples that led to successful pregnancies after artificial insemination. In conclusion, CASA-derived motility parameters, together with traditional semen assessment methods, give valuable information on sperm quality before and after freezing. Therefore, the identification of ejaculates as "good" or "bad" based on fresh and post-thaw semen parameters studied in the present experiment were good indicators of goat semen freezability, although the fertilizing capacity of frozen-thawed goat spermatozoa are not revealed by this quality study. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  7. Characterization and Effects of Fiber Pull-Outs in Hole Quality of Carbon Fiber Reinforced Plastics Composite.

    PubMed

    Alizadeh Ashrafi, Sina; Miller, Peter W; Wandro, Kevin M; Kim, Dave

    2016-10-13

    Hole quality plays a crucial role in the production of close-tolerance holes utilized in aircraft assembly. Through drilling experiments of carbon fiber-reinforced plastic composites (CFRP), this study investigates the impact of varying drilling feed and speed conditions on fiber pull-out geometries and resulting hole quality parameters. For this study, hole quality parameters include hole size variance, hole roundness, and surface roughness. Fiber pull-out geometries are quantified by using scanning electron microscope (SEM) images of the mechanically-sectioned CFRP-machined holes, to measure pull-out length and depth. Fiber pull-out geometries and the hole quality parameter results are dependent on the drilling feed and spindle speed condition, which determines the forces and undeformed chip thickness during the process. Fiber pull-out geometries influence surface roughness parameters from a surface profilometer, while their effect on other hole quality parameters obtained from a coordinate measuring machine is minimal.

  8. The Use of Logistics n the Quality Parameters Control System of Material Flow

    ERIC Educational Resources Information Center

    Karpova, Natalia P.; Toymentseva, Irina A.; Shvetsova, Elena V.; Chichkina, Vera D.; Chubarkova, Elena V.

    2016-01-01

    The relevance of the research problem is conditioned on the need to justify the use of the logistics methodologies in the quality parameters control process of material flows. The goal of the article is to develop theoretical principles and practical recommendations for logistical system control in material flows quality parameters. A leading…

  9. Geostatistical Characteristic of Space -Time Variation in Underground Water Selected Quality Parameters in Klodzko Water Intake Area (SW Part of Poland)

    NASA Astrophysics Data System (ADS)

    Namysłowska-Wilczyńska, Barbara

    2016-04-01

    This paper presents selected results of research connected with the development of a (3D) geostatistical hydrogeochemical model of the Klodzko Drainage Basin, dedicated to the spatial and time variation in the selected quality parameters of underground water in the Klodzko water intake area (SW part of Poland). The research covers the period 2011÷2012. Spatial analyses of the variation in various quality parameters, i.e, contents of: ammonium ion [gNH4+/m3], NO3- (nitrate ion) [gNO3/m3], PO4-3 (phosphate ion) [gPO4-3/m3], total organic carbon C (TOC) [gC/m3], pH redox potential and temperature C [degrees], were carried out on the basis of the chemical determinations of the quality parameters of underground water samples taken from the wells in the water intake area. Spatial and time variation in the quality parameters was analyzed on the basis of archival data (period 1977÷1999) for 22 (pump and siphon) wells with a depth ranging from 9.5 to 38.0 m b.g.l., later data obtained (November 2011) from tests of water taken from 14 existing wells. The wells were built in the years 1954÷1998. The water abstraction depth (difference between the terrain elevation and the dynamic water table level) is ranged from 276÷286 m a.s.l., with an average of 282.05 m a.s.l. Dynamic water table level is contained between 6.22 m÷16.44 m b.g.l., with a mean value of 9.64 m b.g.l. The latest data (January 2012) acquired from 3 new piezometers, with a depth of 9÷10m, which were made in other locations in the relevant area. Thematic databases, containing original data on coordinates X, Y (latitude, longitude) and Z (terrain elevation and time - years) and on regionalized variables, i.e. the underground water quality parameters in the Klodzko water intake area determined for different analytical configurations (22 wells, 14 wells, 14 wells + 3 piezometers), were created. Both archival data (acquired in the years 1977÷1999) and the latest data (collected in 2011÷2012) were analyzed. These data were subjected to spatial analyses using statistical and geostatistical methods. The evaluation of basic statistics of the investigated quality parameters, including their histograms of distributions, scatter diagrams between these parameters and also correlation coefficients r were presented in this article. The directional semivariogram function and the ordinary (block) kriging procedure were used to build the 3D geostatistical model. The geostatistical parameters of the theoretical models of directional semivariograms of the studied water quality parameters, calculated along the time interval and along the wells depth (taking into account the terrain elevation), were used in the ordinary (block) kriging estimation. The obtained results of estimation, i.e. block diagrams allowed to determine the levels of increased values Z* of studied underground water quality parameters. Analysis of the variability in the selected quality parameters of underground water for an analyzed area in Klodzko water intake was enriched by referring to the results of geostatistical studies carried out for underground water quality parameters and also for a treated water and in Klodzko water supply system (iron Fe, manganese Mn, ammonium ion NH4+ contents), discussed in earlier works. Spatial and time variation in the latter-mentioned parameters was analysed on the basis of the data (2007÷2011, 2008÷2011). Generally, the behaviour of the underground water quality parameters has been found to vary in space and time. Thanks to the spatial analyses of the variation in the quality parameters in the Kłodzko underground water intake area some regularities (trends) in the variation in water quality have been identified.

  10. Characterization and Effects of Fiber Pull-Outs in Hole Quality of Carbon Fiber Reinforced Plastics Composite

    PubMed Central

    Alizadeh Ashrafi, Sina; Miller, Peter W.; Wandro, Kevin M.; Kim, Dave

    2016-01-01

    Hole quality plays a crucial role in the production of close-tolerance holes utilized in aircraft assembly. Through drilling experiments of carbon fiber-reinforced plastic composites (CFRP), this study investigates the impact of varying drilling feed and speed conditions on fiber pull-out geometries and resulting hole quality parameters. For this study, hole quality parameters include hole size variance, hole roundness, and surface roughness. Fiber pull-out geometries are quantified by using scanning electron microscope (SEM) images of the mechanically-sectioned CFRP-machined holes, to measure pull-out length and depth. Fiber pull-out geometries and the hole quality parameter results are dependent on the drilling feed and spindle speed condition, which determines the forces and undeformed chip thickness during the process. Fiber pull-out geometries influence surface roughness parameters from a surface profilometer, while their effect on other hole quality parameters obtained from a coordinate measuring machine is minimal. PMID:28773950

  11. Monitoring green leaf tea quality parameters of different TV clones grown in northeast India using satellite data.

    PubMed

    Dutta, Rishiraj

    2013-08-15

    This study tries to quantify the effects of green leaf tea parameters that influence tea quality in Northeast India. The study is to identify the different parameters that have a significant influence on tea quality through the use of remote sensing. It investigates the methods for estimating tea quality based on remotely sensed Normalized Difference Vegetation Index (NDVI) data. Attention focused on high yielding TV clones (TV1, TV18, TV22, TV23, TV25 and TV26). NDVI was obtained from ASTER images. Statistical analysis shows that NDVI has a strong significant effect on the caffeine content followed by epicatechin (EC), epigallocatechin (EGC) and to some extent in other chemical parameters. Relationships therefore exist between quality parameters and remote sensing in particular for the TV clones. This leads to the conclusion that NDVI has a large potential to be used for monitoring tea quality of individual cultivars in the future. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Correlations among Stress Parameters, Meat and Carcass Quality Parameters in Pigs

    PubMed Central

    Dokmanovic, Marija; Baltic, Milan Z.; Duric, Jelena; Ivanovic, Jelena; Popovic, Ljuba; Todorovic, Milica; Markovic, Radmila; Pantic, Srdan

    2015-01-01

    Relationships among different stress parameters (lairage time and blood level of lactate and cortisol), meat quality parameters (initial and ultimate pH value, temperature, drip loss, sensory and instrumental colour, marbling) and carcass quality parameters (degree of rigor mortis and skin damages, hot carcass weight, carcass fat thickness, meatiness) were determined in pigs (n = 100) using Pearson correlations. After longer lairage, blood lactate (p<0.05) and degree of injuries (p<0.001) increased, meat became darker (p<0.001), while drip loss decreased (p<0.05). Higher lactate was associated with lower initial pH value (p<0.01), higher temperature (p<0.001) and skin blemishes score (p<0.05) and more developed rigor mortis (p<0.05), suggesting that lactate could be a predictor of both meat quality and the level of preslaughter stress. Cortisol affected carcass quality, so higher levels of cortisol were associated with increased hot carcass weight, carcass fat thickness on the back and at the sacrum and marbling, but also with decreased meatiness. The most important meat quality parameters (pH and temperature after 60 minutes) deteriorated when blood lactate concentration was above 12 mmol/L. PMID:25656214

  13. Biometric parameters of the bream (Abramis brama) as indicators for long-term changes in fish health and environmental quality--data from the German ESB.

    PubMed

    Teubner, Diana; Paulus, Martin; Veith, Michael; Klein, Roland

    2015-02-01

    Piscifaunal health depends upon the state and quality of the aquatic environment. Variations in physical condition of fish may therefore be attributed to changes in environmental quality. Based on time series of up to 20 years of biometric data of bream from multiple sampling sites of the German environmental specimen bank (ESB), this study assessed whether changes in biometric parameters are able to indicate long-term alterations in fish health and environmental quality. Evaluated biometric parameters of fish health comprised length and weight of individuals of a defined age class, the condition factor, lipid content and hepatosomatic index (HSI). Although there are negative trends of the HSI, the overall development of health parameters can be interpreted as positive. This seems to suggest that health parameters conclusively mirror the long-term improvement of water quality in the selected rivers. However, the applicability of the condition factor as well as lipid content as indicators for fish health remained subject to restrictions. Altogether, the results from the ESB confirmed the high value of biometric parameters for monitoring of long-term changes in state and quality of aquatic ecosystems.

  14. Quality assessment and artificial neural networks modeling for characterization of chemical and physical parameters of potable water.

    PubMed

    Salari, Marjan; Salami Shahid, Esmaeel; Afzali, Seied Hosein; Ehteshami, Majid; Conti, Gea Oliveri; Derakhshan, Zahra; Sheibani, Solmaz Nikbakht

    2018-04-22

    Today, due to the increase in the population, the growth of industry and the variety of chemical compounds, the quality of drinking water has decreased. Five important river water quality properties such as: dissolved oxygen (DO), total dissolved solids (TDS), total hardness (TH), alkalinity (ALK) and turbidity (TU) were estimated by parameters such as: electric conductivity (EC), temperature (T), and pH that could be measured easily with almost no costs. Simulate water quality parameters were examined with two methods of modeling include mathematical and Artificial Neural Networks (ANN). Mathematical methods are based on polynomial fitting with least square method and ANN modeling algorithms are feed-forward networks. All conditions/circumstances covered by neural network modeling were tested for all parameters in this study, except for Alkalinity. All optimum ANN models developed to simulate water quality parameters had precision value as R-value close to 0.99. The ANN model extended to simulate alkalinity with R-value equals to 0.82. Moreover, Surface fitting techniques were used to refine data sets. Presented models and equations are reliable/useable tools for studying water quality parameters at similar rivers, as a proper replacement for traditional water quality measuring equipment's. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Parameter-based estimation of CT dose index and image quality using an in-house android™-based software

    NASA Astrophysics Data System (ADS)

    Mubarok, S.; Lubis, L. E.; Pawiro, S. A.

    2016-03-01

    Compromise between radiation dose and image quality is essential in the use of CT imaging. CT dose index (CTDI) is currently the primary dosimetric formalisms in CT scan, while the low and high contrast resolutions are aspects indicating the image quality. This study was aimed to estimate CTDIvol and image quality measures through a range of exposure parameters variation. CTDI measurements were performed using PMMA (polymethyl methacrylate) phantom of 16 cm diameter, while the image quality test was conducted by using catphan ® 600. CTDI measurements were carried out according to IAEA TRS 457 protocol using axial scan mode, under varied parameters of tube voltage, collimation or slice thickness, and tube current. Image quality test was conducted accordingly under the same exposure parameters with CTDI measurements. An Android™ based software was also result of this study. The software was designed to estimate the value of CTDIvol with maximum difference compared to actual CTDIvol measurement of 8.97%. Image quality can also be estimated through CNR parameter with maximum difference to actual CNR measurement of 21.65%.

  16. Evaluation of Shiraz wastewater treatment plant effluent quality for agricultural irrigation by Canadian Water Quality Index (CWQI)

    PubMed Central

    2013-01-01

    Background Using treated wastewater in agriculture irrigation could be a realistic solution for the shortage of fresh water in Iran, however, it is associated with environmental and health threats; therefore, effluent quality assessment is quite necessary before use. The present study aimed to evaluate the physicochemical and microbial quality of Shiraz wastewater treatment plant effluent for being used in agricultural irrigation. In this study, 20 physicochemical and 3 microbial parameters were measured during warm (April to September) and cold months (October to march). Using the measured parameters and the Canadian Water Quality Index, the quality of the effluent was determined in both warm and cold seasons and in all the seasons together. Results The calculated index for the physicochemical parameters in the effluent was equal (87) in warm and cold months and it was obtained as 85 for the seasons all together. When the microbial parameters were used in order to calculate the index, it declined to 67 in warm and cold seasons and 64 in all the seasons together. Also, it was found that three physicochemical parameters (TDS, EC, and NO3) and three microbial parameters (Fecal coliform, Helminthes egg, and Total coliform) had the most contribution to the reduction of the index value. Conclusions The results showed that the physicochemical quality of Shiraz Wastewater Treatment Plant Effluent was good for irrigation in the warm, cold, and total of the two kinds of seasons. However, by applying the microbial parameter, the index value declined dramatically and the quality of the effluent was marginal. PMID:23566673

  17. Effects of process parameters on the molding quality of the micro-needle array

    NASA Astrophysics Data System (ADS)

    Qiu, Z. J.; Ma, Z.; Gao, S.

    2016-07-01

    Micro-needle array, which is used in medical applications, is a kind of typical injection molded products with microstructures. Due to its tiny micro-features size and high aspect ratios, it is more likely to produce short shots defects, leading to poor molding quality. The injection molding process of the micro-needle array was studied in this paper to find the effects of the process parameters on the molding quality of the micro-needle array and to provide theoretical guidance for practical production of high-quality products. With the shrinkage ratio and warpage of micro needles as the evaluation indices of the molding quality, the orthogonal experiment was conducted and the analysis of variance was carried out. According to the results, the contribution rates were calculated to determine the influence of various process parameters on molding quality. The single parameter method was used to analyse the main process parameter. It was found that the contribution rate of the holding pressure on shrinkage ratio and warpage reached 83.55% and 94.71% respectively, far higher than that of the other parameters. The study revealed that the holding pressure is the main factor which affects the molding quality of micro-needle array so that it should be focused on in order to obtain plastic parts with high quality in the practical production.

  18. Temporal variability and climatology of hydrodynamic, water property and water quality parameters in the West Johor Strait of Singapore.

    PubMed

    Behera, Manasa Ranjan; Chun, Cui; Palani, Sundarambal; Tkalich, Pavel

    2013-12-15

    The study presents a baseline variability and climatology study of measured hydrodynamic, water properties and some water quality parameters of West Johor Strait, Singapore at hourly-to-seasonal scales to uncover their dependency and correlation to one or more drivers. The considered parameters include, but not limited by sea surface elevation, current magnitude and direction, solar radiation and air temperature, water temperature, salinity, chlorophyll-a and turbidity. FFT (Fast Fourier Transform) analysis is carried out for the parameters to delineate relative effect of tidal and weather drivers. The group and individual correlations between the parameters are obtained by principal component analysis (PCA) and cross-correlation (CC) technique, respectively. The CC technique also identifies the dependency and time lag between driving natural forces and dependent water property and water quality parameters. The temporal variability and climatology of the driving forces and the dependent parameters are established at the hourly, daily, fortnightly and seasonal scales. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. A COMPARATIVE STUDY ON PARAMETERS USED FOR CHARACTERIZING COTTON SHORT FIBERS

    USDA-ARS?s Scientific Manuscript database

    The quantity of short cotton fibers in a cotton sample is an important cotton quality parameter which impacts yarn production performance and yarn quality. Researchers have proposed different parameters for characterizing the amount of short fibers in a cotton sample. A comprehensive study was car...

  20. SU-F-P-64: The Impact of Plan Complexity Parameters On the Plan Quality and Deliverability of Volumetric Modulated Arc Therapy with Canonical Correlation Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jin, X; Yi, J; Xie, C

    Purpose: To evaluate the impact of complexity indices on the plan quality and deliverability of volumetric modulated arc therapy (VMAT), and to determine the most significant parameters in the generation of an ideal VMAT plan. Methods: A multi-dimensional exploratory statistical method, canonical correlation analysis (CCA) was adopted to study the correlations between VMAT parameters of complexity, quality and deliverability, as well as their contribution weights with 32 two-arc VMAT nasopharyngeal cancer (NPC) patients and 31 one-arc VMAT prostate cancer patients. Results: The MU per arc (MU/Arc) and MU per control point (MU/CP) of NPC were 337.8±25.2 and 3.7±0.3, respectively, whichmore » were significantly lower than those of prostate cancer patients (MU/Arc : 506.9±95.4, MU/CP : 5.6±1.1). The plan complexity indices indicated that two-arc VMAT plans were more complex than one-arc VMAT plans. Plan quality comparison confirmed that one-arc VMAT plans had a high quality than two-arc VMAT plans. CCA results implied that plan complexity parameters were highly correlated with plan quality with the first two canonical correlations of 0.96, 0.88 (both p<0.001) and significantly correlated with deliverability with the first canonical correlation of 0.79 (p<0.001), plan quality and deliverability was also correlated with the first canonical correlation of 0.71 (p=0.02). Complexity parameters of MU/CP, segment area (SA) per CP, percent of MU/CP less 3 and planning target volume (PTV) were weighted heavily in correlation with plan quality and deliveability . Similar results obtained from individual NPC and prostate CCA analysis. Conclusion: Relationship between complexity, quality, and deliverability parameters were investigated with CCA. MU, SA related parameters and PTV volume were found to have strong effect on the plan quality and deliverability. The presented correlation among different quantified parameters could be used to improve the plan quality and the efficiency of the radiotherapy process when creating a complex VMAT plan.« less

  1. Parameter optimization of flux-aided backing-submerged arc welding by using Taguchi method

    NASA Astrophysics Data System (ADS)

    Pu, Juan; Yu, Shengfu; Li, Yuanyuan

    2017-07-01

    Flux-aided backing-submerged arc welding has been conducted on D36 steel with thickness of 20 mm. The effects of processing parameters such as welding current, voltage, welding speed and groove angle on welding quality were investigated by Taguchi method. The optimal welding parameters were predicted and the individual importance of each parameter on welding quality was evaluated by examining the signal-to-noise ratio and analysis of variance (ANOVA) results. The importance order of the welding parameters for the welding quality of weld bead was: welding current > welding speed > groove angle > welding voltage. The welding quality of weld bead increased gradually with increasing welding current and welding speed and decreasing groove angle. The optimum values of the welding current, welding speed, groove angle and welding voltage were found to be 1050 A, 27 cm/min, 40∘ and 34 V, respectively.

  2. Investigation of water quality parameters at selected points on the Tennessee River

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The thermal and water quality parameters in the vicinity of widows Creek Steam Generation Plant were investigated. The water quality analysis and temperature profiles are presented for 24 sampling sites.

  3. Evaluation of stream water quality in Atlanta, Georgia, and the surrounding region (USA)

    USGS Publications Warehouse

    Peters, N.E.; Kandell, S.J.

    1999-01-01

    A water-quality index (WQI) was developed from historical data (1986-1995) for streams in the Atlanta Region and augmented with 'new' and generally more comprehensive biweekly data on four small urban streams, representing an industrial area, a developed medium-density residential area and developing and developed low-density residential areas. Parameter WQIs were derived from percentile ranks of individual water-quality parameter values for each site by normalizing the constituent ranks for values from all sites in the area for a base period, i.e. 1990-1995. WQIs were developed primarily for nutrient-related parameters due to data availability. Site WQIs, which were computed by averaging the parameter WQIs, range from 0.2 (good quality) to 0.8 (poor quality), and increased downstream of known nutrient sources. Also, annual site WQI decreases from 1986 to 1995 at most long-term monitoring sites. Annual site WQI for individual parameters correlated with annual hydrological characteristics, particularly runoff, precipitation quantity, and water yield, reflecting the effect of dilution on parameter values. The WQIs of the four small urban streams were evaluated for the core-nutrient-related parameters, parameters for specific dissolved trace metal concentrations and sediment characteristics, and a species diversity index for the macro-invertebrate taxa. The site WQI for the core-nutrient-related parameters used in the retrospective analysis was, as expected, the worst for the industrial area and the best for the low-density residential areas. However, macro-invertebrate data indicate that although the species at the medium-density residential site were diverse, the taxa at the site were for species tolerant of degraded water quality. Furthermore, although a species-diversity index indicates no substantial difference between the two low-density residential areas, the number for macro-invertebrates for the developing area was much less than that for the developed area, consistent with observations of recent sediment problems probably associated with construction in the basin. However, sediment parameters were similar for the two sites suggesting that the routine biweekly measurements may not capture the short-term increases in sediment transport associated with rainstorms. The WQI technique is limited by the number and types of parameters included in it, the general conditions of those parameters for the range of conditions in area streams, and by the effects of external factors, such as hydrology, and therefore, should be used with caution.

  4. Optimal design of monitoring networks for multiple groundwater quality parameters using a Kalman filter: application to the Irapuato-Valle aquifer.

    PubMed

    Júnez-Ferreira, H E; Herrera, G S; González-Hita, L; Cardona, A; Mora-Rodríguez, J

    2016-01-01

    A new method for the optimal design of groundwater quality monitoring networks is introduced in this paper. Various indicator parameters were considered simultaneously and tested for the Irapuato-Valle aquifer in Mexico. The steps followed in the design were (1) establishment of the monitoring network objectives, (2) definition of a groundwater quality conceptual model for the study area, (3) selection of the parameters to be sampled, and (4) selection of a monitoring network by choosing the well positions that minimize the estimate error variance of the selected indicator parameters. Equal weight for each parameter was given to most of the aquifer positions and a higher weight to priority zones. The objective for the monitoring network in the specific application was to obtain a general reconnaissance of the water quality, including water types, water origin, and first indications of contamination. Water quality indicator parameters were chosen in accordance with this objective, and for the selection of the optimal monitoring sites, it was sought to obtain a low-uncertainty estimate of these parameters for the entire aquifer and with more certainty in priority zones. The optimal monitoring network was selected using a combination of geostatistical methods, a Kalman filter and a heuristic optimization method. Results show that when monitoring the 69 locations with higher priority order (the optimal monitoring network), the joint average standard error in the study area for all the groundwater quality parameters was approximately 90 % of the obtained with the 140 available sampling locations (the set of pilot wells). This demonstrates that an optimal design can help to reduce monitoring costs, by avoiding redundancy in data acquisition.

  5. CROSS-DISCIPLINARY PHYSICS AND RELATED AREAS OF SCIENCE AND TECHNOLOGY: Order parameters and synchronization of FitzHugh-Nagumo small-world networks

    NASA Astrophysics Data System (ADS)

    Li, Yan-Long; Ma, Jun; Zhang, Wei; Liu, Yan-Jun

    2009-10-01

    This paper numerically investigates the order parameter and synchronisation in the small world connected FitzHugh-Nagumo excitable systems. The simulations show that the order parameter continuously decreases with increasing D, the quality of the synchronisation worsens for large noise intensity. As the coupling intensity goes up, the quality of the synchronisation worsens, and it finds that the larger rewiring probability becomes the larger order parameter. It obtains the complete phase diagram for a wide range of values of noise intensity D and control parameter g.

  6. Comparison of Free-Breathing With Navigator-Triggered Technique in Diffusion Weighted Imaging for Evaluation of Small Hepatocellular Carcinoma: Effect on Image Quality and Intravoxel Incoherent Motion Parameters.

    PubMed

    Shan, Yan; Zeng, Meng-su; Liu, Kai; Miao, Xi-Yin; Lin, Jiang; Fu, Cai xia; Xu, Peng-ju

    2015-01-01

    To evaluate the effect on image quality and intravoxel incoherent motion (IVIM) parameters of small hepatocellular carcinoma (HCC) from choice of either free-breathing (FB) or navigator-triggered (NT) diffusion-weighted (DW) imaging. Thirty patients with 37 small HCCs underwent IVIM DW imaging using 12 b values (0-800 s/mm) with 2 sequences: NT, FB. A biexponential analysis with the Bayesian method yielded true diffusion coefficient (D), pseudodiffusion coefficient (D*), and perfusion fraction (f) in small HCCs and liver parenchyma. Apparent diffusion coefficient (ADC) was also calculated. The acquisition time and image quality scores were assessed for 2 sequences. Independent sample t test was used to compare image quality, signal intensity ratio, IVIM parameters, and ADC values between the 2 sequences; reproducibility of IVIM parameters, and ADC values between 2 sequences was assessed with the Bland-Altman method (BA-LA). Image quality with NT sequence was superior to that with FB acquisition (P = 0.02). The mean acquisition time for FB scheme was shorter than that of NT sequence (6 minutes 14 seconds vs 10 minutes 21 seconds ± 10 seconds P < 0.01). The signal intensity ratio of small HCCs did not vary significantly between the 2 sequences. The ADC and IVIM parameters from the 2 sequences show no significant difference. Reproducibility of D*and f parameters in small HCC was poor (BA-LA: 95% confidence interval, -180.8% to 189.2% for D* and -133.8% to 174.9% for f). A moderate reproducibility of D and ADC parameters was observed (BA-LA: 95% confidence interval, -83.5% to 76.8% for D and -74.4% to 88.2% for ADC) between the 2 sequences. The NT DW imaging technique offers no advantage in IVIM parameters measurements of small HCC except better image quality, whereas FB technique offers greater confidence in fitted diffusion parameters for matched acquisition periods.

  7. Simulation modeling for stratified breast cancer screening - a systematic review of cost and quality of life assumptions.

    PubMed

    Arnold, Matthias

    2017-12-02

    The economic evaluation of stratified breast cancer screening gains momentum, but produces also very diverse results. Systematic reviews so far focused on modeling techniques and epidemiologic assumptions. However, cost and utility parameters received only little attention. This systematic review assesses simulation models for stratified breast cancer screening based on their cost and utility parameters in each phase of breast cancer screening and care. A literature review was conducted to compare economic evaluations with simulation models of personalized breast cancer screening. Study quality was assessed using reporting guidelines. Cost and utility inputs were extracted, standardized and structured using a care delivery framework. Studies were then clustered according to their study aim and parameters were compared within the clusters. Eighteen studies were identified within three study clusters. Reporting quality was very diverse in all three clusters. Only two studies in cluster 1, four studies in cluster 2 and one study in cluster 3 scored high in the quality appraisal. In addition to the quality appraisal, this review assessed if the simulation models were consistent in integrating all relevant phases of care, if utility parameters were consistent and methodological sound and if cost were compatible and consistent in the actual parameters used for screening, diagnostic work up and treatment. Of 18 studies, only three studies did not show signs of potential bias. This systematic review shows that a closer look into the cost and utility parameter can help to identify potential bias. Future simulation models should focus on integrating all relevant phases of care, using methodologically sound utility parameters and avoiding inconsistent cost parameters.

  8. [Correlation between physical characteristics of sticks and quality of traditional Chinese medicine pills prepared by plastic molded method].

    PubMed

    Wang, Ling; Xian, Jiechen; Hong, Yanlong; Lin, Xiao; Feng, Yi

    2012-05-01

    To quantify the physical characteristics of sticks of traditional Chinese medicine (TCM) honeyed pills prepared by the plastic molded method and the correlation of adhesiveness and plasticity-related parameters of sticks and quality of pills, in order to find major parameters and the appropriate range impacting pill quality. Sticks were detected by texture analyzer for their physical characteristic parameters such as hardness and compression action, and pills were observed by visual evaluation for their quality. The correlation of both data was determined by the stepwise discriminant analysis. Stick physical characteristic parameter l(CD) can exactly depict the adhesiveness, with the discriminant equation of Y0 - Y1 = 6.415 - 41.594l(CD). When Y0 < Y1, pills were scattered well; when Y0 > Y1, pills were adhesive with each other. Pills' physical characteristic parameters l(CD) and l(AC), Ar, Tr can exactly depict smoothness of pills, with the discriminant equation of Z0 - Z1 = -195.318 + 78.79l(AC) - 3 258. 982Ar + 3437.935Tr. When Z0 < Z1, pills were smooth on surface. When Z0 > Z1, pills were rough on surface. The stepwise discriminant analysis is made to show the obvious correlation between key physical characteristic parameters l(CD) and l(AC), Ar, Tr of sticks and appearance quality of pills, defining the molding process for preparing pills by the plastic molded and qualifying ranges of key physical characteristic parameters characterizing intermediate sticks, in order to provide theoretical basis for prescription screening and technical parameter adjustment for pills.

  9. Image quality assessment for CT used on small animals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cisneros, Isabela Paredes, E-mail: iparedesc@unal.edu.co; Agulles-Pedrós, Luis, E-mail: lagullesp@unal.edu.co

    Image acquisition on a CT scanner is nowadays necessary in almost any kind of medical study. Its purpose, to produce anatomical images with the best achievable quality, implies the highest diagnostic radiation exposure to patients. Image quality can be measured quantitatively based on parameters such as noise, uniformity and resolution. This measure allows the determination of optimal parameters of operation for the scanner in order to get the best diagnostic image. A human Phillips CT scanner is the first one minded for veterinary-use exclusively in Colombia. The aim of this study was to measure the CT image quality parameters usingmore » an acrylic phantom and then, using the computational tool MATLAB, determine these parameters as a function of current value and window of visualization, in order to reduce dose delivery by keeping the appropriate image quality.« less

  10. Image quality assessment for CT used on small animals

    NASA Astrophysics Data System (ADS)

    Cisneros, Isabela Paredes; Agulles-Pedrós, Luis

    2016-07-01

    Image acquisition on a CT scanner is nowadays necessary in almost any kind of medical study. Its purpose, to produce anatomical images with the best achievable quality, implies the highest diagnostic radiation exposure to patients. Image quality can be measured quantitatively based on parameters such as noise, uniformity and resolution. This measure allows the determination of optimal parameters of operation for the scanner in order to get the best diagnostic image. A human Phillips CT scanner is the first one minded for veterinary-use exclusively in Colombia. The aim of this study was to measure the CT image quality parameters using an acrylic phantom and then, using the computational tool MatLab, determine these parameters as a function of current value and window of visualization, in order to reduce dose delivery by keeping the appropriate image quality.

  11. Weld analysis and control system

    NASA Technical Reports Server (NTRS)

    Kennedy, Larry Z. (Inventor); Rodgers, Michael H. (Inventor); Powell, Bradley W. (Inventor); Burroughs, Ivan A. (Inventor); Goode, K. Wayne (Inventor)

    1994-01-01

    The invention is a Weld Analysis and Control System developed for active weld system control through real time weld data acquisition. Closed-loop control is based on analysis of weld system parameters and weld geometry. The system is adapted for use with automated welding apparatus having a weld controller which is capable of active electronic control of all aspects of a welding operation. Enhanced graphics and data displays are provided for post-weld analysis. The system provides parameter acquisition, including seam location which is acquired for active torch cross-seam positioning. Torch stand-off is also monitored for control. Weld bead and parent surface geometrical parameters are acquired as an indication of weld quality. These parameters include mismatch, peaking, undercut, underfill, crown height, weld width, puddle diameter, and other measurable information about the weld puddle regions, such as puddle symmetry, etc. These parameters provide a basis for active control as well as post-weld quality analysis and verification. Weld system parameters, such as voltage, current and wire feed rate, are also monitored and archived for correlation with quality parameters.

  12. WATGIS: A GIS-Based Lumped Parameter Water Quality Model

    Treesearch

    Glenn P. Fernandez; George M. Chescheir; R. Wayne Skaggs; Devendra M. Amatya

    2002-01-01

    A Geographic Information System (GIS)­based, lumped parameter water quality model was developed to estimate the spatial and temporal nitrogen­loading patterns for lower coastal plain watersheds in eastern North Carolina. The model uses a spatially distributed delivery ratio (DR) parameter to account for nitrogen retention or loss along a drainage network. Delivery...

  13. Effects of farm management practices and transport duration on stress response and meat quality traits of suckling goat kids.

    PubMed

    Alcalde, M J; Suárez, M D; Rodero, E; Álvarez, R; Sáez, M I; Martínez, T F

    2017-09-01

    Studies aimed to assess up to what extent farming and transport previous to slaughtering might affect physiology and meat quality in young goat kids are needed, with the ultimate purpose of promoting practices that minimize stress in these animals. In this regard the effects of on-farm management and transport duration on some physiological responses and meat quality parameters in goat kids were assessed. Two farms representing 'high' and 'low' welfare-friendly management practices were selected. In total, 32 suckling kids were withdrawn from each farm, transported by road for 2 or 6 h, and then slaughtered. Blood samples were collected both on-farm and in the slaughterhouse, and biochemistry, cell counts and haematocrit were determined. After slaughtering, carcass quality parameters were measured. Longissimus dorsi muscle was dissected and pH, colour parameters, water holding capacity and shear force were measured throughout 8-day ageing period. Results indicate that, regardless its duration, transport caused significant effects on some blood parameters suggesting stress in live animals, like glucose, cortisol or creatine kinase. Despite the marked stress status in animals, this condition was not decisively reflected on L. dorsi quality parameters, but some effects were observed regarding fat cover in carcasses and colour parameters. The results suggest that postmortem changes throughout ageing were more decisive in terms of meat quality than stressful management either on-farm or during transport.

  14. Prediction of HDR quality by combining perceptually transformed display measurements with machine learning

    NASA Astrophysics Data System (ADS)

    Choudhury, Anustup; Farrell, Suzanne; Atkins, Robin; Daly, Scott

    2017-09-01

    We present an approach to predict overall HDR display quality as a function of key HDR display parameters. We first performed subjective experiments on a high quality HDR display that explored five key HDR display parameters: maximum luminance, minimum luminance, color gamut, bit-depth and local contrast. Subjects rated overall quality for different combinations of these display parameters. We explored two models | a physical model solely based on physically measured display characteristics and a perceptual model that transforms physical parameters using human vision system models. For the perceptual model, we use a family of metrics based on a recently published color volume model (ICT-CP), which consists of the PQ luminance non-linearity (ST2084) and LMS-based opponent color, as well as an estimate of the display point spread function. To predict overall visual quality, we apply linear regression and machine learning techniques such as Multilayer Perceptron, RBF and SVM networks. We use RMSE and Pearson/Spearman correlation coefficients to quantify performance. We found that the perceptual model is better at predicting subjective quality than the physical model and that SVM is better at prediction than linear regression. The significance and contribution of each display parameter was investigated. In addition, we found that combined parameters such as contrast do not improve prediction. Traditional perceptual models were also evaluated and we found that models based on the PQ non-linearity performed better.

  15. The monitoring method of water quality in Ciliwung River for post restoration

    NASA Astrophysics Data System (ADS)

    Diyanti; Saleh Pallu, Muh.; Tahir Lopa, Rita; Arsyad Thaha, M.

    2018-04-01

    Ciliwung River is the biggest river which flows across DKI Jakarta, where the river flows through the city, the settlements, and slums in Jakarta. Problems that occur in the Ciliwung River in Jakarta one of which is the quality of water. This research using some datas, there are secondary and primary data like river dimension and visualization of water quality of Ciliwung River. This research using a descriptive method which describes the comparison between a physical and chemical parameter for the durationn of three (3) years post-restoration. The physical parameters used in this reasearch are temperature and TDS, the chemical parameters are pH dan DO. Based on the result of data analyzing, we get the temperature average parameter pre-restoration is 28.30°C and TDS level is 151.96 mg/L, so the logical of standard quality criteria match with class 3. Post-restoration got the temperature 22.06°C and TDS level 224.20mg/L, so that water quality criteria match with class 2. For the chemical parameters the average pH and DO values pre-restoration are 6.84 and 4mg/L, respectively which match with class 2 category. Post-restoration, the chemical parameter about pH level is 7.41 and DO 8.4 mg/L, so the standard quality criteria match with class 1.

  16. Water Quality Assessment in the Harbin Reach of the Songhuajiang River (China) Based on a Fuzzy Rough Set and an Attribute Recognition Theoretical Model

    PubMed Central

    An, Yan; Zou, Zhihong; Li, Ranran

    2014-01-01

    A large number of parameters are acquired during practical water quality monitoring. If all the parameters are used in water quality assessment, the computational complexity will definitely increase. In order to reduce the input space dimensions, a fuzzy rough set was introduced to perform attribute reduction. Then, an attribute recognition theoretical model and entropy method were combined to assess water quality in the Harbin reach of the Songhuajiang River in China. A dataset consisting of ten parameters was collected from January to October in 2012. Fuzzy rough set was applied to reduce the ten parameters to four parameters: BOD5, NH3-N, TP, and F. coli (Reduct A). Considering that DO is a usual parameter in water quality assessment, another reduct, including DO, BOD5, NH3-N, TP, TN, F, and F. coli (Reduct B), was obtained. The assessment results of Reduct B show a good consistency with those of Reduct A, and this means that DO is not always necessary to assess water quality. The results with attribute reduction are not exactly the same as those without attribute reduction, which can be attributed to the α value decided by subjective experience. The assessment results gained by the fuzzy rough set obviously reduce computational complexity, and are acceptable and reliable. The model proposed in this paper enhances the water quality assessment system. PMID:24675643

  17. Distribution of water quality parameters in Dhemaji district, Assam (India).

    PubMed

    Buragohain, Mridul; Bhuyan, Bhabajit; Sarma, H P

    2010-07-01

    The primary objective of this study is to present a statistically significant water quality database of Dhemaji district, Assam (India) with special reference to pH, fluoride, nitrate, arsenic, iron, sodium and potassium. 25 water samples collected from different locations of five development blocks in Dhemaji district have been studied separately. The implications presented are based on statistical analyses of the raw data. Normal distribution statistics and reliability analysis (correlation and covariance matrix) have been employed to find out the distribution pattern, localisation of data, and other related information. Statistical observations show that all the parameters under investigation exhibit non uniform distribution with a long asymmetric tail either on the right or left side of the median. The width of the third quartile was consistently found to be more than the second quartile for each parameter. Differences among mean, mode and median, significant skewness and kurtosis value indicate that the distribution of various water quality parameters in the study area is widely off normal. Thus, the intrinsic water quality is not encouraging due to unsymmetrical distribution of various water quality parameters in the study area.

  18. Development of wavelet-ANN models to predict water quality parameters in Hilo Bay, Pacific Ocean.

    PubMed

    Alizadeh, Mohamad Javad; Kavianpour, Mohamad Reza

    2015-09-15

    The main objective of this study is to apply artificial neural network (ANN) and wavelet-neural network (WNN) models for predicting a variety of ocean water quality parameters. In this regard, several water quality parameters in Hilo Bay, Pacific Ocean, are taken under consideration. Different combinations of water quality parameters are applied as input variables to predict daily values of salinity, temperature and DO as well as hourly values of DO. The results demonstrate that the WNN models are superior to the ANN models. Also, the hourly models developed for DO prediction outperform the daily models of DO. For the daily models, the most accurate model has R equal to 0.96, while for the hourly model it reaches up to 0.98. Overall, the results show the ability of the model to monitor the ocean parameters, in condition with missing data, or when regular measurement and monitoring are impossible. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Evaluation of the influence of acquisition parameters of microtomography in image quality applied by carbonate rocks

    NASA Astrophysics Data System (ADS)

    Santos, T. M. P.; Machado, A. S.; Araújo, O. M. O.; Ferreira, C. G.; Lopes, R. T.

    2018-03-01

    X-ray computed microtomography is a powerful nondestructive technique for 2D and 3D structure analysis. However, parameters used in acquisition promote directs influence in qualitative and quantitative results in characterization of samples, due image resolution. The aim of this study is value the influence of theses parameters in results through of tests changing these parameters in different situations and system characterization. Results demonstrate those pixel size and detector matrixes are the main parameters that influence in resolution and image quality. Microtomography was considered an excellent technique for characterization using the best image resolution possible.

  20. Quality parameters analysis of optical imaging systems with enhanced focal depth using the Wigner distribution function

    PubMed

    Zalvidea; Colautti; Sicre

    2000-05-01

    An analysis of the Strehl ratio and the optical transfer function as imaging quality parameters of optical elements with enhanced focal length is carried out by employing the Wigner distribution function. To this end, we use four different pupil functions: a full circular aperture, a hyper-Gaussian aperture, a quartic phase plate, and a logarithmic phase mask. A comparison is performed between the quality parameters and test images formed by these pupil functions at different defocus distances.

  1. DRAINMOD-GIS: a lumped parameter watershed scale drainage and water quality model

    Treesearch

    G.P. Fernandez; G.M. Chescheir; R.W. Skaggs; D.M. Amatya

    2006-01-01

    A watershed scale lumped parameter hydrology and water quality model that includes an uncertainty analysis component was developed and tested on a lower coastal plain watershed in North Carolina. Uncertainty analysis was used to determine the impacts of uncertainty in field and network parameters of the model on the predicted outflows and nitrate-nitrogen loads at the...

  2. Recovery of Item Parameters in the Nominal Response Model: A Comparison of Marginal Maximum Likelihood Estimation and Markov Chain Monte Carlo Estimation.

    ERIC Educational Resources Information Center

    Wollack, James A.; Bolt, Daniel M.; Cohen, Allan S.; Lee, Young-Sun

    2002-01-01

    Compared the quality of item parameter estimates for marginal maximum likelihood (MML) and Markov Chain Monte Carlo (MCMC) with the nominal response model using simulation. The quality of item parameter recovery was nearly identical for MML and MCMC, and both methods tended to produce good estimates. (SLD)

  3. General equations for optimal selection of diagnostic image acquisition parameters in clinical X-ray imaging.

    PubMed

    Zheng, Xiaoming

    2017-12-01

    The purpose of this work was to examine the effects of relationship functions between diagnostic image quality and radiation dose on the governing equations for image acquisition parameter variations in X-ray imaging. Various equations were derived for the optimal selection of peak kilovoltage (kVp) and exposure parameter (milliAmpere second, mAs) in computed tomography (CT), computed radiography (CR), and direct digital radiography. Logistic, logarithmic, and linear functions were employed to establish the relationship between radiation dose and diagnostic image quality. The radiation dose to the patient, as a function of image acquisition parameters (kVp, mAs) and patient size (d), was used in radiation dose and image quality optimization. Both logistic and logarithmic functions resulted in the same governing equation for optimal selection of image acquisition parameters using a dose efficiency index. For image quality as a linear function of radiation dose, the same governing equation was derived from the linear relationship. The general equations should be used in guiding clinical X-ray imaging through optimal selection of image acquisition parameters. The radiation dose to the patient could be reduced from current levels in medical X-ray imaging.

  4. Investigation into the influence of laser energy input on selective laser melted thin-walled parts by response surface method

    NASA Astrophysics Data System (ADS)

    Liu, Yang; Zhang, Jian; Pang, Zhicong; Wu, Weihui

    2018-04-01

    Selective laser melting (SLM) provides a feasible way for manufacturing of complex thin-walled parts directly, however, the energy input during SLM process, namely derived from the laser power, scanning speed, layer thickness and scanning space, etc. has great influence on the thin wall's qualities. The aim of this work is to relate the thin wall's parameters (responses), namely track width, surface roughness and hardness to the process parameters considered in this research (laser power, scanning speed and layer thickness) and to find out the optimal manufacturing conditions. Design of experiment (DoE) was used by implementing composite central design to achieve better manufacturing qualities. Mathematical models derived from the statistical analysis were used to establish the relationships between the process parameters and the responses. Also, the effects of process parameters on each response were determined. Then, a numerical optimization was performed to find out the optimal process set at which the quality features are at their desired values. Based on this study, the relationship between process parameters and SLMed thin-walled structure was revealed and thus, the corresponding optimal process parameters can be used to manufactured thin-walled parts with high quality.

  5. Workflow for Criticality Assessment Applied in Biopharmaceutical Process Validation Stage 1.

    PubMed

    Zahel, Thomas; Marschall, Lukas; Abad, Sandra; Vasilieva, Elena; Maurer, Daniel; Mueller, Eric M; Murphy, Patrick; Natschläger, Thomas; Brocard, Cécile; Reinisch, Daniela; Sagmeister, Patrick; Herwig, Christoph

    2017-10-12

    Identification of critical process parameters that impact product quality is a central task during regulatory requested process validation. Commonly, this is done via design of experiments and identification of parameters significantly impacting product quality (rejection of the null hypothesis that the effect equals 0). However, parameters which show a large uncertainty and might result in an undesirable product quality limit critical to the product, may be missed. This might occur during the evaluation of experiments since residual/un-modelled variance in the experiments is larger than expected a priori. Estimation of such a risk is the task of the presented novel retrospective power analysis permutation test. This is evaluated using a data set for two unit operations established during characterization of a biopharmaceutical process in industry. The results show that, for one unit operation, the observed variance in the experiments is much larger than expected a priori, resulting in low power levels for all non-significant parameters. Moreover, we present a workflow of how to mitigate the risk associated with overlooked parameter effects. This enables a statistically sound identification of critical process parameters. The developed workflow will substantially support industry in delivering constant product quality, reduce process variance and increase patient safety.

  6. Spatial variability of theaflavins and thearubigins fractions and their impact on black tea quality.

    PubMed

    Bhuyan, Lakshi Prasad; Borah, Paban; Sabhapondit, Santanu; Gogoi, Ramen; Bhattacharyya, Pradip

    2015-12-01

    The spatial distribution of theaflavin and thearubigin fractions and their impact on black tea quality were investigated using multivariate and geostatistics techniques. Black tea samples were collected from tea gardens of six geographical regions of Assam and West Bengal, India. Total theaflavin (TF) and its four fractions of upper Assam, south bank and North Bank teas were higher than the other regions. Simple theaflavin showed highest significant correlation with tasters' quality. Low molecular weight thearubigins of south bank and North Bank were significantly higher than other regions. Total thearubigin (TR) and its fractions revealed significant positive correlation with tasters' organoleptic valuations. Tea tasters' parameters were significantly and positively correlated with each other. The semivariogram for quality parameters were best represented by gaussian models. The nugget/sill ratio indicated a strong/moderate spatial dependence of the studied parameters. Spatial variation of tea quality parameters may be used for quality assessment in the tea growing areas of India.

  7. [Feedforward control strategy and its application in quality improvement of ethanol precipitation process of danhong injection].

    PubMed

    Yan, Bin-Jun; Guo, Zheng-Tai; Qu, Hai-Bin; Zhao, Bu-Chang; Zhao, Tao

    2013-06-01

    In this work, a feedforward control strategy basing on the concept of quality by design was established for the manufacturing process of traditional Chinese medicine to reduce the impact of the quality variation of raw materials on drug. In the research, the ethanol precipitation process of Danhong injection was taken as an application case of the method established. Box-Behnken design of experiments was conducted. Mathematical models relating the attributes of the concentrate, the process parameters and the quality of the supernatants produced were established. Then an optimization model for calculating the best process parameters basing on the attributes of the concentrate was built. The quality of the supernatants produced by ethanol precipitation with optimized and non-optimized process parameters were compared. The results showed that using the feedforward control strategy for process parameters optimization can control the quality of the supernatants effectively. The feedforward control strategy proposed can enhance the batch-to-batch consistency of the supernatants produced by ethanol precipitation.

  8. [Quant efficiency of the detection as a quality parameter of the visualization equipment].

    PubMed

    Morgun, O N; Nemchenko, K E; Rogov, Iu V

    2003-01-01

    The critical parameter of notion "quant efficiency of detection" is defined in the paper. Different methods of specifying the detection quant efficiency (DQE) are under discussion. Thus, techniques of DQE determination for a whole unit and means of DQE finding at terminal space frequency are addressed. The notion of DQE at zero frequency is in the focus of attention. Finally, difficulties occurring in determining the above parameter as well as its disadvantages (as a parameter characterizing the quality of X-ray irradiation visualizing systems) are also discussed.

  9. Method and apparatus for assessing weld quality

    DOEpatents

    Smartt, Herschel B.; Kenney, Kevin L.; Johnson, John A.; Carlson, Nancy M.; Clark, Denis E.; Taylor, Paul L.; Reutzel, Edward W.

    2001-01-01

    Apparatus for determining a quality of a weld produced by a welding device according to the present invention includes a sensor operatively associated with the welding device. The sensor is responsive to at least one welding process parameter during a welding process and produces a welding process parameter signal that relates to the at least one welding process parameter. A computer connected to the sensor is responsive to the welding process parameter signal produced by the sensor. A user interface operatively associated with the computer allows a user to select a desired welding process. The computer processes the welding process parameter signal produced by the sensor in accordance with one of a constant voltage algorithm, a short duration weld algorithm or a pulsed current analysis module depending on the desired welding process selected by the user. The computer produces output data indicative of the quality of the weld.

  10. Estimation of distributional parameters for censored trace level water quality data: 2. Verification and applications

    USGS Publications Warehouse

    Helsel, Dennis R.; Gilliom, Robert J.

    1986-01-01

    Estimates of distributional parameters (mean, standard deviation, median, interquartile range) are often desired for data sets containing censored observations. Eight methods for estimating these parameters have been evaluated by R. J. Gilliom and D. R. Helsel (this issue) using Monte Carlo simulations. To verify those findings, the same methods are now applied to actual water quality data. The best method (lowest root-mean-squared error (rmse)) over all parameters, sample sizes, and censoring levels is log probability regression (LR), the method found best in the Monte Carlo simulations. Best methods for estimating moment or percentile parameters separately are also identical to the simulations. Reliability of these estimates can be expressed as confidence intervals using rmse and bias values taken from the simulation results. Finally, a new simulation study shows that best methods for estimating uncensored sample statistics from censored data sets are identical to those for estimating population parameters. Thus this study and the companion study by Gilliom and Helsel form the basis for making the best possible estimates of either population parameters or sample statistics from censored water quality data, and for assessments of their reliability.

  11. Real-time parameter optimization based on neural network for smart injection molding

    NASA Astrophysics Data System (ADS)

    Lee, H.; Liau, Y.; Ryu, K.

    2018-03-01

    The manufacturing industry has been facing several challenges, including sustainability, performance and quality of production. Manufacturers attempt to enhance the competitiveness of companies by implementing CPS (Cyber-Physical Systems) through the convergence of IoT(Internet of Things) and ICT(Information & Communication Technology) in the manufacturing process level. Injection molding process has a short cycle time and high productivity. This features have been making it suitable for mass production. In addition, this process is used to produce precise parts in various industry fields such as automobiles, optics and medical devices. Injection molding process has a mixture of discrete and continuous variables. In order to optimized the quality, variables that is generated in the injection molding process must be considered. Furthermore, Optimal parameter setting is time-consuming work to predict the optimum quality of the product. Since the process parameter cannot be easily corrected during the process execution. In this research, we propose a neural network based real-time process parameter optimization methodology that sets optimal process parameters by using mold data, molding machine data, and response data. This paper is expected to have academic contribution as a novel study of parameter optimization during production compare with pre - production parameter optimization in typical studies.

  12. The effect of laser focus and process parameters on microstructure and mechanical properties of SLM Inconel 718

    NASA Astrophysics Data System (ADS)

    Bean, Glenn E.; Witkin, David B.; McLouth, Tait D.; Zaldivar, Rafael J.

    2018-02-01

    Research on the selective laser melting (SLM) method of laser powder bed fusion additive manufacturing (AM) has shown that surface and internal quality of AM parts is directly related to machine settings such as laser energy density, scanning strategies, and atmosphere. To optimize laser parameters for improved component quality, the energy density is typically controlled via laser power, scanning rate, and scanning strategy, but can also be controlled by changing the spot size via laser focal plane shift. Present work being conducted by The Aerospace Corporation was initiated after observing inconsistent build quality of parts printed using OEM-installed settings. Initial builds of Inconel 718 witness geometries using OEM laser parameters were evaluated for surface roughness, density, and porosity while varying energy density via laser focus shift. Based on these results, hardware and laser parameter adjustments were conducted in order to improve build quality and consistency. Tensile testing was also conducted to investigate the effect of build plate location and laser settings on SLM 718. This work has provided insight into the limitations of OEM parameters compared with optimized parameters towards the goal of manufacturing aerospace-grade parts, and has led to the development of a methodology for laser parameter tuning that can be applied to other alloy systems. Additionally, evidence was found that for 718, which derives its strength from post-manufacturing heat treatment, there is a possibility that tensile testing may not be perceptive to defects which would reduce component performance. Ongoing research is being conducted towards identifying appropriate testing and analysis methods for screening and quality assurance.

  13. Distributed sensor architecture for intelligent control that supports quality of control and quality of service.

    PubMed

    Poza-Lujan, Jose-Luis; Posadas-Yagüe, Juan-Luis; Simó-Ten, José-Enrique; Simarro, Raúl; Benet, Ginés

    2015-02-25

    This paper is part of a study of intelligent architectures for distributed control and communications systems. The study focuses on optimizing control systems by evaluating the performance of middleware through quality of service (QoS) parameters and the optimization of control using Quality of Control (QoC) parameters. The main aim of this work is to study, design, develop, and evaluate a distributed control architecture based on the Data-Distribution Service for Real-Time Systems (DDS) communication standard as proposed by the Object Management Group (OMG). As a result of the study, an architecture called Frame-Sensor-Adapter to Control (FSACtrl) has been developed. FSACtrl provides a model to implement an intelligent distributed Event-Based Control (EBC) system with support to measure QoS and QoC parameters. The novelty consists of using, simultaneously, the measured QoS and QoC parameters to make decisions about the control action with a new method called Event Based Quality Integral Cycle. To validate the architecture, the first five Braitenberg vehicles have been implemented using the FSACtrl architecture. The experimental outcomes, demonstrate the convenience of using jointly QoS and QoC parameters in distributed control systems.

  14. Distributed Sensor Architecture for Intelligent Control that Supports Quality of Control and Quality of Service

    PubMed Central

    Poza-Lujan, Jose-Luis; Posadas-Yagüe, Juan-Luis; Simó-Ten, José-Enrique; Simarro, Raúl; Benet, Ginés

    2015-01-01

    This paper is part of a study of intelligent architectures for distributed control and communications systems. The study focuses on optimizing control systems by evaluating the performance of middleware through quality of service (QoS) parameters and the optimization of control using Quality of Control (QoC) parameters. The main aim of this work is to study, design, develop, and evaluate a distributed control architecture based on the Data-Distribution Service for Real-Time Systems (DDS) communication standard as proposed by the Object Management Group (OMG). As a result of the study, an architecture called Frame-Sensor-Adapter to Control (FSACtrl) has been developed. FSACtrl provides a model to implement an intelligent distributed Event-Based Control (EBC) system with support to measure QoS and QoC parameters. The novelty consists of using, simultaneously, the measured QoS and QoC parameters to make decisions about the control action with a new method called Event Based Quality Integral Cycle. To validate the architecture, the first five Braitenberg vehicles have been implemented using the FSACtrl architecture. The experimental outcomes, demonstrate the convenience of using jointly QoS and QoC parameters in distributed control systems. PMID:25723145

  15. Testing the quality of images for permanent magnet desktop MRI systems using specially designed phantoms.

    PubMed

    Qiu, Jianfeng; Wang, Guozhu; Min, Jiao; Wang, Xiaoyan; Wang, Pengcheng

    2013-12-21

    Our aim was to measure the performance of desktop magnetic resonance imaging (MRI) systems using specially designed phantoms, by testing imaging parameters and analysing the imaging quality. We designed multifunction phantoms with diameters of 18 and 60 mm for desktop MRI scanners in accordance with the American Association of Physicists in Medicine (AAPM) report no. 28. We scanned the phantoms with three permanent magnet 0.5 T desktop MRI systems, measured the MRI image parameters, and analysed imaging quality by comparing the data with the AAPM criteria and Chinese national standards. Image parameters included: resonance frequency, high contrast spatial resolution, low contrast object detectability, slice thickness, geometrical distortion, signal-to-noise ratio (SNR), and image uniformity. The image parameters of three desktop MRI machines could be measured using our specially designed phantoms, and most parameters were in line with MRI quality control criterion, including: resonance frequency, high contrast spatial resolution, low contrast object detectability, slice thickness, geometrical distortion, image uniformity and slice position accuracy. However, SNR was significantly lower than in some references. The imaging test and quality control are necessary for desktop MRI systems, and should be performed with the applicable phantom and corresponding standards.

  16. Content dependent selection of image enhancement parameters for mobile displays

    NASA Astrophysics Data System (ADS)

    Lee, Yoon-Gyoo; Kang, Yoo-Jin; Kim, Han-Eol; Kim, Ka-Hee; Kim, Choon-Woo

    2011-01-01

    Mobile devices such as cellular phones and portable multimedia player with capability of playing terrestrial digital multimedia broadcasting (T-DMB) contents have been introduced into consumer market. In this paper, content dependent image quality enhancement method for sharpness and colorfulness and noise reduction is presented to improve perceived image quality on mobile displays. Human visual experiments are performed to analyze viewers' preference. Relationship between the objective measures and the optimal values of image control parameters are modeled by simple lookup tables based on the results of human visual experiments. Content dependent values of image control parameters are determined based on the calculated measures and predetermined lookup tables. Experimental results indicate that dynamic selection of image control parameters yields better image quality.

  17. Variation of Water Quality Parameters with Siltation Depth for River Ichamati Along International Border with Bangladesh Using Multivariate Statistical Techniques

    NASA Astrophysics Data System (ADS)

    Roy, P. K.; Pal, S.; Banerjee, G.; Biswas Roy, M.; Ray, D.; Majumder, A.

    2014-12-01

    River is considered as one of the main sources of freshwater all over the world. Hence analysis and maintenance of this water resource is globally considered a matter of major concern. This paper deals with the assessment of surface water quality of the Ichamati river using multivariate statistical techniques. Eight distinct surface water quality observation stations were located and samples were collected. For the samples collected statistical techniques were applied to the physico-chemical parameters and depth of siltation. In this paper cluster analysis is done to determine the relations between surface water quality and siltation depth of river Ichamati. Multiple regressions and mathematical equation modeling have been done to characterize surface water quality of Ichamati river on the basis of physico-chemical parameters. It was found that surface water quality of the downstream river was different from the water quality of the upstream. The analysis of the water quality parameters of the Ichamati river clearly indicate high pollution load on the river water which can be accounted to agricultural discharge, tidal effect and soil erosion. The results further reveal that with the increase in depth of siltation, water quality degraded.

  18. Spatio-Temporal Trends and Identification of Correlated Variables with Water Quality for Drinking-Water Reservoirs

    PubMed Central

    Gu, Qing; Wang, Ke; Li, Jiadan; Ma, Ligang; Deng, Jinsong; Zheng, Kefeng; Zhang, Xiaobin; Sheng, Li

    2015-01-01

    It is widely accepted that characterizing the spatio-temporal trends of water quality parameters and identifying correlated variables with water quality are indispensable for the management and protection of water resources. In this study, cluster analysis was used to classify 56 typical drinking water reservoirs in Zhejiang Province into three groups representing different water quality levels, using data of four water quality parameters for the period 2006–2010. Then, the spatio-temporal trends in water quality were analyzed, assisted by geographic information systems (GIS) technology and statistical analysis. The results indicated that the water quality showed a trend of degradation from southwest to northeast, and the overall water quality level was exacerbated during the study period. Correlation analysis was used to evaluate the relationships between water quality parameters and ten independent variables grouped into four categories (land use, socio-economic factors, geographical features, and reservoir attributes). According to the correlation coefficients, land use and socio-economic indicators were identified as the most significant factors related to reservoir water quality. The results offer insights into the spatio-temporal variations of water quality parameters and factors impacting the water quality of drinking water reservoirs in Zhejiang Province, and they could assist managers in making effective strategies to better protect water resources. PMID:26492263

  19. Spatio-Temporal Trends and Identification of Correlated Variables with Water Quality for Drinking-Water Reservoirs.

    PubMed

    Gu, Qing; Wang, Ke; Li, Jiadan; Ma, Ligang; Deng, Jinsong; Zheng, Kefeng; Zhang, Xiaobin; Sheng, Li

    2015-10-20

    It is widely accepted that characterizing the spatio-temporal trends of water quality parameters and identifying correlated variables with water quality are indispensable for the management and protection of water resources. In this study, cluster analysis was used to classify 56 typical drinking water reservoirs in Zhejiang Province into three groups representing different water quality levels, using data of four water quality parameters for the period 2006-2010. Then, the spatio-temporal trends in water quality were analyzed, assisted by geographic information systems (GIS) technology and statistical analysis. The results indicated that the water quality showed a trend of degradation from southwest to northeast, and the overall water quality level was exacerbated during the study period. Correlation analysis was used to evaluate the relationships between water quality parameters and ten independent variables grouped into four categories (land use, socio-economic factors, geographical features, and reservoir attributes). According to the correlation coefficients, land use and socio-economic indicators were identified as the most significant factors related to reservoir water quality. The results offer insights into the spatio-temporal variations of water quality parameters and factors impacting the water quality of drinking water reservoirs in Zhejiang Province, and they could assist managers in making effective strategies to better protect water resources.

  20. Quality of water for livestock in man-made impoundments in the northern High Plains

    Treesearch

    Mark A. Rumble

    1985-01-01

    Twenty-seven water quality parameters were measured in coal surface mine impoundments, bentonite surface mine impoundments, and livestock ponds in the Northern High Plains. Most impoundments were safe for use as a source for livestock drinking water. Eight water quality parameters were different (a

  1. Relationships of cotton fiber properties to ring-spun yarn quality on selected High Plains cottons

    USDA-ARS?s Scientific Manuscript database

    The objective of this research was to evaluate the adequacy of High Volume Instruement (HVI) and Advanced Fiber Information System (AFIS) fiber quality parameters for predicting quality parameters of ring-spun yarns considering differences in harvest method. Fiber properties measured using the HVI (...

  2. SU-D-12A-06: A Comprehensive Parameter Analysis for Low Dose Cone-Beam CT Reconstruction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu, W; Southern Medical University, Guangzhou; Yan, H

    Purpose: There is always a parameter in compressive sensing based iterative reconstruction (IR) methods low dose cone-beam CT (CBCT), which controls the weight of regularization relative to data fidelity. A clear understanding of the relationship between image quality and parameter values is important. The purpose of this study is to investigate this subject based on experimental data and a representative advanced IR algorithm using Tight-frame (TF) regularization. Methods: Three data sets of a Catphan phantom acquired at low, regular and high dose levels are used. For each tests, 90 projections covering a 200-degree scan range are used for reconstruction. Threemore » different regions-of-interest (ROIs) of different contrasts are used to calculate contrast-to-noise ratios (CNR) for contrast evaluation. A single point structure is used to measure modulation transfer function (MTF) for spatial-resolution evaluation. Finally, we analyze CNRs and MTFs to study the relationship between image quality and parameter selections. Results: It was found that: 1) there is no universal optimal parameter. The optimal parameter value depends on specific task and dose level. 2) There is a clear trade-off between CNR and resolution. The parameter for the best CNR is always smaller than that for the best resolution. 3) Optimal parameters are also dose-specific. Data acquired under a high dose protocol require less regularization, yielding smaller optimal parameter values. 4) Comparing with conventional FDK images, TF-based CBCT images are better under a certain optimally selected parameters. The advantages are more obvious for low dose data. Conclusion: We have investigated the relationship between image quality and parameter values in the TF-based IR algorithm. Preliminary results indicate optimal parameters are specific to both the task types and dose levels, providing guidance for selecting parameters in advanced IR algorithms. This work is supported in part by NIH (1R01CA154747-01)« less

  3. Left Handed Materials Based on Magnetic Nanocomposites

    DTIC Science & Technology

    2006-10-18

    theory that unifies DNMs and SNMs as a function of two flmdamental material parameters: quality factors for permittivity (Qe=e’/e") and permeability (Qu...simultaneously negative effective permeability/uff and permittivity Seff to form LHM or only single negative parameter (SNM) to form negative indexed...developed a theory that unifies DNMs and SNMs as a function of two fundamental material parameters: quality factors for permittivity (Q, = -’/ 6") and

  4. Digital Microwave System Design Guide.

    DTIC Science & Technology

    1984-02-01

    traffic analysis is a continuous effort, setting parameters for subsequent stages of expansion after the system design is finished. 2.1.3 Quality of...operational structure of the user for whom he is providing service. 2.2.3 Quality of Service. In digital communications, the basic performance parameter ...the basic interpretation of system performance is measured in terms of a single parameter , throughput. Throughput can be defined as the number of

  5. A hybrid artificial neural network as a software sensor for optimal control of a wastewater treatment process.

    PubMed

    Choi, D J; Park, H

    2001-11-01

    For control and automation of biological treatment processes, lack of reliable on-line sensors to measure water quality parameters is one of the most important problems to overcome. Many parameters cannot be measured directly with on-line sensors. The accuracy of existing hardware sensors is also not sufficient and maintenance problems such as electrode fouling often cause trouble. This paper deals with the development of software sensor techniques that estimate the target water quality parameter from other parameters using the correlation between water quality parameters. We focus our attention on the preprocessing of noisy data and the selection of the best model feasible to the situation. Problems of existing approaches are also discussed. We propose a hybrid neural network as a software sensor inferring wastewater quality parameter. Multivariate regression, artificial neural networks (ANN), and a hybrid technique that combines principal component analysis as a preprocessing stage are applied to data from industrial wastewater processes. The hybrid ANN technique shows an enhancement of prediction capability and reduces the overfitting problem of neural networks. The result shows that the hybrid ANN technique can be used to extract information from noisy data and to describe the nonlinearity of complex wastewater treatment processes.

  6. Optical spectral signatures of liquids by means of fiber optic technology for product and quality parameter identification

    NASA Astrophysics Data System (ADS)

    Mignani, A. G.; Ciaccheri, L.; Mencaglia, A. A.; Diaz-Herrera, N.; Garcia-Allende, P. B.; Ottevaere, H.; Thienpont, H.; Attilio, C.; Cimato, A.; Francalanci, S.; Paccagnini, A.; Pavone, F. S.

    2009-01-01

    Absorption spectroscopy in the wide 200-1700 nm spectral range is carried out by means of optical fiber instrumentation to achieve a digital mapping of liquids for the prediction of important quality parameters. Extra virgin olive oils from Italy and lubricant oils from turbines with different degrees of degradation were considered as "case studies". The spectral data were processed by means of multivariate analysis so as to obtain a correlation to quality parameters. In practice, the wide range absorption spectra were considered as an optical signature of the liquids from which to extract product quality information. The optical signatures of extra virgin olive oils were used to predict the content of the most important fatty acids. The optical signatures of lubricant oils were used to predict the concentration of the most important parameters for indicating the oil's degree of degradation, such as TAN, JOAP anti-wear index, and water content.

  7. Quality of Life in Patients With Advanced Cancer: Differential Association With Performance Status and Systemic Inflammatory Response.

    PubMed

    Laird, Barry J A; Fallon, Marie; Hjermstad, Marianne J; Tuck, Sharon; Kaasa, Stein; Klepstad, Pål; McMillan, Donald C

    2016-08-10

    Quality of life is a key component of cancer care; however, the factors that determine quality of life are not well understood. The aim of this study was to examine the relationship between quality of life parameters, performance status (PS), and the systemic inflammatory response in patients with advanced cancer. An international biobank of patients with advanced cancer was analyzed. Quality of life was assessed at a single time point by using the European Organisation for Research and Treatment of Cancer Quality of Life Questionnaire C-30 (EORTC QLQ-C30). PS was assessed by using the Eastern Cooperative Oncology Group (ECOG) classification. Systemic inflammation was assessed by using the modified Glasgow Prognostic Score (mGPS), which combines C-reactive protein and albumin. The relationship between quality of life parameters, ECOG PS, and the mGPS was examined. Data were available for 2,520 patients, and the most common cancers were GI (585 patients [22.2%]) and pulmonary (443 patients [17.6%]). The median survival was 4.25 months (interquartile range, 1.36 to 12.9 months). Increasing mGPS (systemic inflammation) and deteriorating PS were associated with deterioration in quality-of-life parameters (P < .001). Increasing systemic inflammation was associated with deterioration in quality-of-life parameters independent of PS. Systemic inflammation was associated with quality-of-life parameters independent of PS in patients with advanced cancer. Further investigation of these relationships in longitudinal studies and investigations of possible effects of attenuating systemic inflammation are now warranted. © 2016 by American Society of Clinical Oncology.

  8. Optimization of Selective Laser Melting by Evaluation Method of Multiple Quality Characteristics

    NASA Astrophysics Data System (ADS)

    Khaimovich, A. I.; Stepanenko, I. S.; Smelov, V. G.

    2018-01-01

    Article describes the adoption of the Taguchi method in selective laser melting process of sector of combustion chamber by numerical and natural experiments for achieving minimum temperature deformation. The aim was to produce a quality part with minimum amount of numeric experiments. For the study, the following optimization parameters (independent factors) were chosen: the laser beam power and velocity; two factors for compensating the effect of the residual thermal stresses: the scale factor of the preliminary correction of the part geometry and the number of additional reinforcing elements. We used an orthogonal plan of 9 experiments with a factor variation at three levels (L9). As quality criterias, the values of distortions for 9 zones of the combustion chamber and the maximum strength of the material of the chamber were chosen. Since the quality parameters are multidirectional, a grey relational analysis was used to solve the optimization problem for multiple quality parameters. As a result, according to the parameters obtained, the combustion chamber segments of the gas turbine engine were manufactured.

  9. Parameter Search Algorithms for Microwave Radar-Based Breast Imaging: Focal Quality Metrics as Fitness Functions.

    PubMed

    O'Loughlin, Declan; Oliveira, Bárbara L; Elahi, Muhammad Adnan; Glavin, Martin; Jones, Edward; Popović, Milica; O'Halloran, Martin

    2017-12-06

    Inaccurate estimation of average dielectric properties can have a tangible impact on microwave radar-based breast images. Despite this, recent patient imaging studies have used a fixed estimate although this is known to vary from patient to patient. Parameter search algorithms are a promising technique for estimating the average dielectric properties from the reconstructed microwave images themselves without additional hardware. In this work, qualities of accurately reconstructed images are identified from point spread functions. As the qualities of accurately reconstructed microwave images are similar to the qualities of focused microscopic and photographic images, this work proposes the use of focal quality metrics for average dielectric property estimation. The robustness of the parameter search is evaluated using experimental dielectrically heterogeneous phantoms on the three-dimensional volumetric image. Based on a very broad initial estimate of the average dielectric properties, this paper shows how these metrics can be used as suitable fitness functions in parameter search algorithms to reconstruct clear and focused microwave radar images.

  10. Remote Sensing Image Quality Assessment Experiment with Post-Processing

    NASA Astrophysics Data System (ADS)

    Jiang, W.; Chen, S.; Wang, X.; Huang, Q.; Shi, H.; Man, Y.

    2018-04-01

    This paper briefly describes the post-processing influence assessment experiment, the experiment includes three steps: the physical simulation, image processing, and image quality assessment. The physical simulation models sampled imaging system in laboratory, the imaging system parameters are tested, the digital image serving as image processing input are produced by this imaging system with the same imaging system parameters. The gathered optical sampled images with the tested imaging parameters are processed by 3 digital image processes, including calibration pre-processing, lossy compression with different compression ratio and image post-processing with different core. Image quality assessment method used is just noticeable difference (JND) subject assessment based on ISO20462, through subject assessment of the gathered and processing images, the influence of different imaging parameters and post-processing to image quality can be found. The six JND subject assessment experimental data can be validated each other. Main conclusions include: image post-processing can improve image quality; image post-processing can improve image quality even with lossy compression, image quality with higher compression ratio improves less than lower ratio; with our image post-processing method, image quality is better, when camera MTF being within a small range.

  11. Uncertainty analyses of the calibrated parameter values of a water quality model

    NASA Astrophysics Data System (ADS)

    Rode, M.; Suhr, U.; Lindenschmidt, K.-E.

    2003-04-01

    For river basin management water quality models are increasingly used for the analysis and evaluation of different management measures. However substantial uncertainties exist in parameter values depending on the available calibration data. In this paper an uncertainty analysis for a water quality model is presented, which considers the impact of available model calibration data and the variance of input variables. The investigation was conducted based on four extensive flowtime related longitudinal surveys in the River Elbe in the years 1996 to 1999 with varying discharges and seasonal conditions. For the model calculations the deterministic model QSIM of the BfG (Germany) was used. QSIM is a one dimensional water quality model and uses standard algorithms for hydrodynamics and phytoplankton dynamics in running waters, e.g. Michaelis Menten/Monod kinetics, which are used in a wide range of models. The multi-objective calibration of the model was carried out with the nonlinear parameter estimator PEST. The results show that for individual flow time related measuring surveys very good agreements between model calculation and measured values can be obtained. If these parameters are applied to deviating boundary conditions, substantial errors in model calculation can occur. These uncertainties can be decreased with an increased calibration database. More reliable model parameters can be identified, which supply reasonable results for broader boundary conditions. The extension of the application of the parameter set on a wider range of water quality conditions leads to a slight reduction of the model precision for the specific water quality situation. Moreover the investigations show that highly variable water quality variables like the algal biomass always allow a smaller forecast accuracy than variables with lower coefficients of variation like e.g. nitrate.

  12. Texas Water Quality Board Teachers Workshop Program.

    ERIC Educational Resources Information Center

    Texas Water Quality Board, Austin.

    These materials are designed for teachers participating in an inservice workshop on water quality. Included in the materials are a workshop agenda, a water awareness pretest, and the various parameters and tests that are used to determine and measure water quality. The parameters are discussed from the standpoint of their potential impact to…

  13. A comparison of different functions for predicted protein model quality assessment.

    PubMed

    Li, Juan; Fang, Huisheng

    2016-07-01

    In protein structure prediction, a considerable number of models are usually produced by either the Template-Based Method (TBM) or the ab initio prediction. The purpose of this study is to find the critical parameter in assessing the quality of the predicted models. A non-redundant template library was developed and 138 target sequences were modeled. The target sequences were all distant from the proteins in the template library and were aligned with template library proteins on the basis of the transformation matrix. The quality of each model was first assessed with QMEAN and its six parameters, which are C_β interaction energy (C_beta), all-atom pairwise energy (PE), solvation energy (SE), torsion angle energy (TAE), secondary structure agreement (SSA), and solvent accessibility agreement (SAE). Finally, the alignment score (score) was also used to assess the quality of model. Hence, a total of eight parameters (i.e., QMEAN, C_beta, PE, SE, TAE, SSA, SAE, score) were independently used to assess the quality of each model. The results indicate that SSA is the best parameter to estimate the quality of the model.

  14. Process Parameter Optimization for Wobbling Laser Spot Welding of Ti6Al4V Alloy

    NASA Astrophysics Data System (ADS)

    Vakili-Farahani, F.; Lungershausen, J.; Wasmer, K.

    Laser beam welding (LBW) coupled with "wobble effect" (fast oscillation of the laser beam) is very promising for high precision micro-joining industry. For this process, similarly to the conventional LBW, the laser welding process parameters play a very significant role in determining the quality of a weld joint. Consequently, four process parameters (laser power, wobble frequency, number of rotations within a single laser pulse and focused position) and 5 responses (penetration, width, heat affected zone (HAZ), area of the fusion zone, area of HAZ and hardness) were investigated for spot welding of Ti6Al4V alloy (grade 5) using a design of experiments (DoE) approach. This paper presents experimental results showing the effects of variating the considered most important process parameters on the spot weld quality of Ti6Al4V alloy. Semi-empirical mathematical models were developed to correlate laser welding parameters to each of the measured weld responses. Adequacies of the models were then examined by various methods such as ANOVA. These models not only allows a better understanding of the wobble laser welding process and predict the process performance but also determines optimal process parameters. Therefore, optimal combination of process parameters was determined considering certain quality criteria set.

  15. Updating national standards for drinking-water: a Philippine experience.

    PubMed

    Lomboy, M; Riego de Dios, J; Magtibay, B; Quizon, R; Molina, V; Fadrilan-Camacho, V; See, J; Enoveso, A; Barbosa, L; Agravante, A

    2017-04-01

    The latest version of the Philippine National Standards for Drinking-Water (PNSDW) was issued in 2007 by the Department of Health (DOH). Due to several issues and concerns, the DOH decided to make an update which is relevant and necessary to meet the needs of the stakeholders. As an output, the water quality parameters are now categorized into mandatory, primary, and secondary. The ten mandatory parameters are core parameters which all water service providers nationwide are obligated to test. These include thermotolerant coliforms or Escherichia coli, arsenic, cadmium, lead, nitrate, color, turbidity, pH, total dissolved solids, and disinfectant residual. The 55 primary parameters are site-specific and can be adopted as enforceable parameters when developing new water sources or when the existing source is at high risk of contamination. The 11 secondary parameters include operational parameters and those that affect the esthetic quality of drinking-water. In addition, the updated PNSDW include new sections: (1) reporting and interpretation of results and corrective actions; (2) emergency drinking-water parameters; (3) proposed Sustainable Development Goal parameters; and (4) standards for other drinking-water sources. The lessons learned and insights gained from the updating of standards are likewise incorporated in this paper.

  16. The association between quality of care and quality of life in long-stay nursing home residents with preserved cognition.

    PubMed

    Kim, Sun Jung; Park, Eun-Cheol; Kim, Sulgi; Nakagawa, Shunichi; Lung, John; Choi, Jong Bum; Ryu, Woo Sang; Min, Too Jae; Shin, Hyun Phil; Kim, Kyudam; Yoo, Ji Won

    2014-03-01

    To assess the overall quality of life of long-stay nursing home residents with preserved cognition, to examine whether the Centers for Medicare and Medicaid Service's Nursing Home Compare 5-star quality rating system reflects the overall quality of life of such residents, and to examine whether residents' demographics and clinical characteristics affect their quality of life. Quality of life was measured using the Participant Outcomes and Status Measures-Nursing Facility survey, which has 10 sections and 63 items. Total scores range from 20 (lowest possible quality of life) to 100 (highest). Long-stay nursing home residents with preserved cognition (n = 316) were interviewed. The average quality- of-life score was 71.4 (SD: 7.6; range: 45.1-93.0). Multilevel regression models revealed that quality of life was associated with physical impairment (parameter estimate = -0.728; P = .04) and depression (parameter estimate = -3.015; P = .01) but not Nursing Home Compare's overall star rating (parameter estimate = 0.683; P = .12) and not pain (parameter estimate = -0.705; P = .47). The 5-star quality rating system did not reflect the quality of life of long-stay nursing home residents with preserved cognition. Notably, pain was not associated with quality of life, but physical impairment and depression were. Copyright © 2014 American Medical Directors Association, Inc. Published by Elsevier Inc. All rights reserved.

  17. Performance evaluation of algebraic reconstruction technique (ART) for prototype chest digital tomosynthesis (CDT) system

    NASA Astrophysics Data System (ADS)

    Lee, Haenghwa; Choi, Sunghoon; Jo, Byungdu; Kim, Hyemi; Lee, Donghoon; Kim, Dohyeon; Choi, Seungyeon; Lee, Youngjin; Kim, Hee-Joung

    2017-03-01

    Chest digital tomosynthesis (CDT) is a new 3D imaging technique that can be expected to improve the detection of subtle lung disease over conventional chest radiography. Algorithm development for CDT system is challenging in that a limited number of low-dose projections are acquired over a limited angular range. To confirm the feasibility of algebraic reconstruction technique (ART) method under variations in key imaging parameters, quality metrics were conducted using LUNGMAN phantom included grand-glass opacity (GGO) tumor. Reconstructed images were acquired from the total 41 projection images over a total angular range of +/-20°. We evaluated contrast-to-noise ratio (CNR) and artifacts spread function (ASF) to investigate the effect of reconstruction parameters such as number of iterations, relaxation parameter and initial guess on image quality. We found that proper value of ART relaxation parameter could improve image quality from the same projection. In this study, proper value of relaxation parameters for zero-image (ZI) and back-projection (BP) initial guesses were 0.4 and 0.6, respectively. Also, the maximum CNR values and the minimum full width at half maximum (FWHM) of ASF were acquired in the reconstructed images after 20 iterations and 3 iterations, respectively. According to the results, BP initial guess for ART method could provide better image quality than ZI initial guess. In conclusion, ART method with proper reconstruction parameters could improve image quality due to the limited angular range in CDT system.

  18. Study on loading path optimization of internal high pressure forming process

    NASA Astrophysics Data System (ADS)

    Jiang, Shufeng; Zhu, Hengda; Gao, Fusheng

    2017-09-01

    In the process of internal high pressure forming, there is no formula to describe the process parameters and forming results. The article use numerical simulation to obtain several input parameters and corresponding output result, use the BP neural network to found their mapping relationship, and with weighted summing method make each evaluating parameters to set up a formula which can evaluate quality. Then put the training BP neural network into the particle swarm optimization, and take the evaluating formula of the quality as adapting formula of particle swarm optimization, finally do the optimization and research at the range of each parameters. The results show that the parameters obtained by the BP neural network algorithm and the particle swarm optimization algorithm can meet the practical requirements. The method can solve the optimization of the process parameters in the internal high pressure forming process.

  19. Effects of temporal and spatial resolution of calibration data on integrated hydrologic water quality model identification

    NASA Astrophysics Data System (ADS)

    Jiang, Sanyuan; Jomaa, Seifeddine; Büttner, Olaf; Rode, Michael

    2014-05-01

    Hydrological water quality modeling is increasingly used for investigating runoff and nutrient transport processes as well as watershed management but it is mostly unclear how data availablity determins model identification. In this study, the HYPE (HYdrological Predictions for the Environment) model, which is a process-based, semi-distributed hydrological water quality model, was applied in two different mesoscale catchments (Selke (463 km2) and Weida (99 km2)) located in central Germany to simulate discharge and inorganic nitrogen (IN) transport. PEST and DREAM(ZS) were combined with the HYPE model to conduct parameter calibration and uncertainty analysis. Split-sample test was used for model calibration (1994-1999) and validation (1999-2004). IN concentration and daily IN load were found to be highly correlated with discharge, indicating that IN leaching is mainly controlled by runoff. Both dynamics and balances of water and IN load were well captured with NSE greater than 0.83 during validation period. Multi-objective calibration (calibrating hydrological and water quality parameters simultaneously) was found to outperform step-wise calibration in terms of model robustness. Multi-site calibration was able to improve model performance at internal sites, decrease parameter posterior uncertainty and prediction uncertainty. Nitrogen-process parameters calibrated using continuous daily averages of nitrate-N concentration observations produced better and more robust simulations of IN concentration and load, lower posterior parameter uncertainty and IN concentration prediction uncertainty compared to the calibration against uncontinuous biweekly nitrate-N concentration measurements. Both PEST and DREAM(ZS) are efficient in parameter calibration. However, DREAM(ZS) is more sound in terms of parameter identification and uncertainty analysis than PEST because of its capability to evolve parameter posterior distributions and estimate prediction uncertainty based on global search and Bayesian inference schemes.

  20. Assessment of derelict soil quality: Abiotic, biotic and functional approaches.

    PubMed

    Vincent, Quentin; Auclerc, Apolline; Beguiristain, Thierry; Leyval, Corinne

    2018-02-01

    The intensification and subsequent closing down of industrial activities during the last century has left behind large surfaces of derelict lands. Derelict soils have low fertility, can be contaminated, and many of them remain unused. However, with the increasing demand of soil surfaces, they might be considered as a resource, for example for non-food biomass production. The study of their physico-chemical properties and of their biodiversity and biological activity may provide indications for their potential re-use. The objective of our study was to investigate the quality of six derelict soils, considering abiotic, biotic, and functional parameters. We studied (i) the soil bacteria, fungi, meso- and macro-fauna and plant communities of six different derelict soils (two from coking plants, one from a settling pond, two constructed ones made from different substrates and remediated soil, and an inert waste storage one), and (ii) their decomposition function based on the decomposer trophic network, enzyme activities, mineralization activity, and organic pollutant degradation. Biodiversity levels in these soils were high, but all biotic parameters, except the mycorrhizal colonization level, discriminated them. Multivariate analysis showed that biotic parameters co-varied more with fertility proxies than with soil contamination parameters. Similarly, functional parameters significantly co-varied with abiotic parameters. Among functional parameters, macro-decomposer proportion, enzyme activity, average mineralization capacity, and microbial polycyclic aromatic hydrocarbon degraders were useful to discriminate the soils. We assessed their quality by combining abiotic, biotic, and functional parameters: the compost-amended constructed soil displayed the highest quality, while the settling pond soil and the contaminated constructed soil displayed the lowest. Although differences among the soils were highlighted, this study shows that derelict soils may provide a biodiversity ecosystem service and are functional for decomposition. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. [Optimize dropping process of Ginkgo biloba dropping pills by using design space approach].

    PubMed

    Shen, Ji-Chen; Wang, Qing-Qing; Chen, An; Pan, Fang-Lai; Gong, Xing-Chu; Qu, Hai-Bin

    2017-07-01

    In this paper, a design space approach was applied to optimize the dropping process of Ginkgo biloba dropping pills. Firstly, potential critical process parameters and potential process critical quality attributes were determined through literature research and pre-experiments. Secondly, experiments were carried out according to Box-Behnken design. Then the critical process parameters and critical quality attributes were determined based on the experimental results. Thirdly, second-order polynomial models were used to describe the quantitative relationships between critical process parameters and critical quality attributes. Finally, a probability-based design space was calculated and verified. The verification results showed that efficient production of Ginkgo biloba dropping pills can be guaranteed by operating within the design space parameters. The recommended operation ranges for the critical dropping process parameters of Ginkgo biloba dropping pills were as follows: dropping distance of 5.5-6.7 cm, and dropping speed of 59-60 drops per minute, providing a reference for industrial production of Ginkgo biloba dropping pills. Copyright© by the Chinese Pharmaceutical Association.

  2. Water-quality assessment of stormwater runoff from a heavily used urban highway bridge in Miami, Florida

    USGS Publications Warehouse

    McKenzie, Donald J.; Irwin, G.A.

    1983-01-01

    Runoff from a heavily-traveled, 1.43-acre bridge section of Interstate-95 in Miami, Florida, was comprehensively monitored for both quality and quantity during five selected storms between November 1979 and May 1981. For most water-quality parameters, 6 to 11 samples were collected during each of the 5 runoff events. Concentrations of most parameters in the runoff were quite variable both during individual storm events and among the five storm events; however, the ranges in parameter concentration were about the same magnitude report for numerous other highway and urban drainages. Data were normalized to estimate the average, discharge-weighted parameter loads per storm per acre of bridge surface and results suggested that the most significant factor influencing stormwater loads was parameter concentration. Rainfall intensity and runoff volume, however, influenced rates of loading. The total number of antecedent dry days and traffic volume did not appear to be conspicously related to either runoff concentrations or loads. (USGS)

  3. Quality parameters of mango and potential of non-destructive techniques for their measurement - a review.

    PubMed

    Jha, S N; Narsaiah, K; Sharma, A D; Singh, M; Bansal, S; Kumar, R

    2010-01-01

    The king of fruits "Mango" (Mangifera indica L.) is very nutritious and rich in carotenes. India produces about 50% of the total world's mango. Many researchers have reported the maturity indices and quality parameters for determination of harvesting time and eating quality. The methods currently used for determination of quality of mango are mostly based on the biochemical analysis, which leads to destruction of the fruits. Numerous works are being carried out to explore some non-destructive methods such as Near Infrared (NIR), Nuclear Magnetic Resonance (NMR), X-ray and Computed Tomography (CT), electronic nose, machine vision and ultrasound for quality determination of fruits. This paper deals with some recent work reported on quality parameters, harvesting and post-harvest treatments in relation to quality of mango fruits and reviews on some of the potential non-destructive techniques that can be explored for quality determination of mango cultivars.

  4. Investigation of water quality parameters at selected points on the Tennessee River

    NASA Technical Reports Server (NTRS)

    Manger, M. C.

    1973-01-01

    Physical, chemical, and biological water quality parameters have been investigated at the Widow's Creek steam plant. The water quality parameters and field site locations have been selected so as to be compatible with the interests and needs of the Environmental Application Office at Marshall Space Flight Center. All sampling and testing was conducted as directed in the 13th Edition of Standard Methods of Analysis for Water and Waste Water or as suggested by NASA'S Technical Officer. Data is presented in a form compatible with that presently being collected by other agencies.

  5. Remote measurements of water pollution with a lidar polarimeter

    NASA Technical Reports Server (NTRS)

    Sheives, T. C.; Rouse, J. W., Jr.; Mayo, W. T., Jr.

    1974-01-01

    This paper examines a dual polarization laser backscatter system as a method for remote measurements of certain water quality parameters. Analytical models for describing the backscatter from turbid water and oil on turbid water are presented and compared with experimental data. Laser backscatter field measurements from natural waterways are presented and compared with simultaneous ground observations of the water quality parameters: turbidity, suspended solids, and transmittance. The results of this study show that the analytical models appear valid and that the sensor investigated is applicable to remote measurements of these water quality parameters and oil spills on water.-

  6. The determination of water quality and metal concentrations of Ampang Hilir Lake, Selangor, Peninsular Malaysia.

    PubMed

    Said, Khaled S A; Shuhaimi-Othman, M; Ahmad, A K

    2012-05-01

    A study of water quality parameters (temperature, conductivity, total dissolved solid, dissolved oxygen, pH and water hardness) in Ampang Hilir Lake was conducted in January, April, July and October 2010. The water quality parameters were tested and recorded at different sampling stations chosen randomly using Hydrolab Data Sonde 4 and Surveyor 4 a water quality multi probe (USA). Six metals which were cadmium, chromium, lead, nickel, zinc and copper were determined in five different compartments of the lake namely water, total suspended solids, plankton, sediment and fish. The metals concentration were determined by Inductively Coupled Plasma Mass Spectrometer (ICP-MS), Perkin Elmer Elan, model 9000.The water quality parameters were compared with National Water Quality Standard (NWQS Malaysia) while metal concentrations were compared with Malaysian and international standards. The study shows that water quality parameters are of class 2. This condition is suitable for recreational activities where body contact is allowed and suitable for sensitive fishing activities. Furthermore, metal concentrations were found to be lower than the international standards, therefore toxic effects for these metals would be rarely observed and the adverse effects to aquatic organisms would not frequently occur.

  7. Meteorology drives ambient air quality in a valley: a case of Sukinda chromite mine, one among the ten most polluted areas in the world.

    PubMed

    Mishra, Soumya Ranjan; Pradhan, Rudra Pratap; Prusty, B Anjan Kumar; Sahu, Sanjat Kumar

    2016-07-01

    The ambient air quality (AAQ) assessment was undertaken in Sukinda Valley, the chromite hub of India. The possible correlations of meteorological variables with different air quality parameters (PM10, PM2.5, SO2, NO2 and CO) were examined. Being the fourth most polluted area in the globe, Sukinda Valley has always been under attention of researchers, for hexavalent chromium contamination of water. The monitoring was carried out from December 2013 through May 2014 at six strategic locations in the residential and commercial areas around the mining cluster of Sukinda Valley considering the guidelines of Central Pollution Control Board (CPCB). In addition, meteorological parameters viz., temperature, relative humidity, wind speed, wind direction and rainfall, were also monitored. The air quality data were subjected to a general linear model (GLM) coupled with one-way analysis of variance (ANOVA) test for testing the significant difference in the concentration of various parameters among seasons and stations. Further, a two-tailed Pearson's correlation test helped in understanding the influence of meteorological parameters on dispersion of pollutants in the area. All the monitored air quality parameters varied significantly among the monitoring stations suggesting (i) the distance of sampling location to the mine site and other allied activities, (ii) landscape features and topography and (iii) meteorological parameters to be the forcing functions. The area was highly polluted with particulate matters, and in most of the cases, the PM level exceeded the National Ambient Air Quality Standards (NAAQS). The meteorological parameters seemed to play a major role in the dispersion of pollutants around the mine clusters. The role of wind direction, wind speed and temperature was apparent in dispersion of the particulate matters from their source of generation to the surrounding residential and commercial areas of the mine.

  8. Multidimensional correlation among plan complexity, quality and deliverability parameters for volumetric-modulated arc therapy using canonical correlation analysis.

    PubMed

    Shen, Lanxiao; Chen, Shan; Zhu, Xiaoyang; Han, Ce; Zheng, Xiaomin; Deng, Zhenxiang; Zhou, Yongqiang; Gong, Changfei; Xie, Congying; Jin, Xiance

    2018-03-01

    A multidimensional exploratory statistical method, canonical correlation analysis (CCA), was applied to evaluate the impact of complexity parameters on the plan quality and deliverability of volumetric-modulated arc therapy (VMAT) and to determine parameters in the generation of an ideal VMAT plan. Canonical correlations among complexity, quality and deliverability parameters of VMAT, as well as the contribution weights of different parameters were investigated with 71 two-arc VMAT nasopharyngeal cancer (NPC) patients, and further verified with 28 one-arc VMAT prostate cancer patients. The average MU and MU per control point (MU/CP) for two-arc VMAT plans were 702.6 ± 55.7 and 3.9 ± 0.3 versus 504.6 ± 99.2 and 5.6 ± 1.1 for one-arc VMAT plans, respectively. The individual volume-based 3D gamma passing rates of clinical target volume (γCTV) and planning target volume (γPTV) for NPC and prostate cancer patients were 85.7% ± 9.0% vs 92.6% ± 7.8%, and 88.0% ± 7.6% vs 91.2% ± 7.7%, respectively. Plan complexity parameters of NPC patients were correlated with plan quality (P = 0.047) and individual volume-based 3D gamma indices γ(IV) (P = 0.01), in which, MU/CP and segment area (SA) per control point (SA/CP) were weighted highly in correlation with γ(IV) , and SA/CP, percentage of CPs with SA < 5 × 5 cm2 (%SA < 5 × 5 cm2) and PTV volume were weighted highly in correlation with plan quality with coefficients of 0.98, 0.68 and -0.99, respectively. Further verification with one-arc VMAT plans demonstrated similar results. In conclusion, MU, SA-related parameters and PTV volume were found to have strong effects on the plan quality and deliverability.

  9. Multidimensional correlation among plan complexity, quality and deliverability parameters for volumetric-modulated arc therapy using canonical correlation analysis

    PubMed Central

    Shen, Lanxiao; Chen, Shan; Zhu, Xiaoyang; Han, Ce; Zheng, Xiaomin; Deng, Zhenxiang; Zhou, Yongqiang; Gong, Changfei; Jin, Xiance

    2018-01-01

    Abstract A multidimensional exploratory statistical method, canonical correlation analysis (CCA), was applied to evaluate the impact of complexity parameters on the plan quality and deliverability of volumetric-modulated arc therapy (VMAT) and to determine parameters in the generation of an ideal VMAT plan. Canonical correlations among complexity, quality and deliverability parameters of VMAT, as well as the contribution weights of different parameters were investigated with 71 two-arc VMAT nasopharyngeal cancer (NPC) patients, and further verified with 28 one-arc VMAT prostate cancer patients. The average MU and MU per control point (MU/CP) for two-arc VMAT plans were 702.6 ± 55.7 and 3.9 ± 0.3 versus 504.6 ± 99.2 and 5.6 ± 1.1 for one-arc VMAT plans, respectively. The individual volume-based 3D gamma passing rates of clinical target volume (γCTV) and planning target volume (γPTV) for NPC and prostate cancer patients were 85.7% ± 9.0% vs 92.6% ± 7.8%, and 88.0% ± 7.6% vs 91.2% ± 7.7%, respectively. Plan complexity parameters of NPC patients were correlated with plan quality (P = 0.047) and individual volume-based 3D gamma indices γ(IV) (P = 0.01), in which, MU/CP and segment area (SA) per control point (SA/CP) were weighted highly in correlation with γ(IV) , and SA/CP, percentage of CPs with SA < 5 × 5 cm2 (%SA < 5 × 5 cm2) and PTV volume were weighted highly in correlation with plan quality with coefficients of 0.98, 0.68 and −0.99, respectively. Further verification with one-arc VMAT plans demonstrated similar results. In conclusion, MU, SA-related parameters and PTV volume were found to have strong effects on the plan quality and deliverability. PMID:29415196

  10. Water quality parameters and total aerobic bacterial and vibrionaceae loads in eastern oysters (Crassostrea virginica) from oyster gardening sites

    USDA-ARS?s Scientific Manuscript database

    Oyster gardening is a practice designed to restore habitat for marine life and to improve water quality. This study determined physical and chemical water quality parameters at two oyster gardening sites in the Delaware Inland Bays and compared them with total aerobic bacteria and Vibrionaceae conc...

  11. Facial motion parameter estimation and error criteria in model-based image coding

    NASA Astrophysics Data System (ADS)

    Liu, Yunhai; Yu, Lu; Yao, Qingdong

    2000-04-01

    Model-based image coding has been given extensive attention due to its high subject image quality and low bit-rates. But the estimation of object motion parameter is still a difficult problem, and there is not a proper error criteria for the quality assessment that are consistent with visual properties. This paper presents an algorithm of the facial motion parameter estimation based on feature point correspondence and gives the motion parameter error criteria. The facial motion model comprises of three parts. The first part is the global 3-D rigid motion of the head, the second part is non-rigid translation motion in jaw area, and the third part consists of local non-rigid expression motion in eyes and mouth areas. The feature points are automatically selected by a function of edges, brightness and end-node outside the blocks of eyes and mouth. The numbers of feature point are adjusted adaptively. The jaw translation motion is tracked by the changes of the feature point position of jaw. The areas of non-rigid expression motion can be rebuilt by using block-pasting method. The estimation approach of motion parameter error based on the quality of reconstructed image is suggested, and area error function and the error function of contour transition-turn rate are used to be quality criteria. The criteria reflect the image geometric distortion caused by the error of estimated motion parameters properly.

  12. The combined effect of wet granulation process parameters and dried granule moisture content on tablet quality attributes.

    PubMed

    Gabbott, Ian P; Al Husban, Farhan; Reynolds, Gavin K

    2016-09-01

    A pharmaceutical compound was used to study the effect of batch wet granulation process parameters in combination with the residual moisture content remaining after drying on granule and tablet quality attributes. The effect of three batch wet granulation process parameters was evaluated using a multivariate experimental design, with a novel constrained design space. Batches were characterised for moisture content, granule density, crushing strength, porosity, disintegration time and dissolution. Mechanisms of the effect of the process parameters on the granule and tablet quality attributes are proposed. Water quantity added during granulation showed a significant effect on granule density and tablet dissolution rate. Mixing time showed a significant effect on tablet crushing strength, and mixing speed showed a significant effect on the distribution of tablet crushing strengths obtained. The residual moisture content remaining after granule drying showed a significant effect on tablet crushing strength. The effect of moisture on tablet tensile strength has been reported before, but not in combination with granulation parameters and granule properties, and the impact on tablet dissolution was not assessed. Correlations between the energy input during granulation, the density of granules produced, and the quality attributes of the final tablets were also identified. Understanding the impact of the granulation and drying process parameters on granule and tablet properties provides a basis for process optimisation and scaling. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Effect of environment and variety on the relationships of wheat grain physical and chemical characteristics with ethanol yield.

    PubMed

    Awole, Kedija D; Kettlewell, Peter S; Hare, Martin C; Agu, Reginald C; Brosnan, James M; Bringhurst, Thomas A

    2012-02-01

    Following the Renewable Transport Fuel Obligation (RTFO), there is an increasing demand for wheat grain for liquid biofuel in the UK. In order to enhance productivity of the bioethanol industry, good quality wheat must be used. A total of 84 grain samples comprising 14 varieties collected from 11 sites in two harvest years were analysed for a range of grain quality parameters and ethanol yield (EY). The grain quality parameters studied were starch and protein concentration, specific weight, grain density, packing efficiency, thousand-grain weight (TGW), grain length, width, length/width ratio and hardness index. Regression analysis was used to establish the relationships between grain quality parameters and EY. Apart from grain length and density, all grain parameters had significant relationships with EY. In the order of importance, protein concentration, TGW, packing efficiency and specific weight showed good relationships with EY. All other parameters, including starch concentration, showed a poor correlation with EY. EY and the relationship with the grain parameters were affected more by environment than by variety. Some sites gave consistently higher EY than others. When site and variety were considered with TGW and protein, a good prediction of EY could be made (variance accounted for = 87%). Combining TGW and protein concentration could be a better indicator of EY than the current practice of specific weight and protein. Copyright © 2011 Society of Chemical Industry.

  14. Development of colour and firmness in strawberry crops is UV light sensitive, but colour is not a good predictor of several quality parameters.

    PubMed

    Ordidge, Matthew; García-Macías, Paulina; Battey, Nicholas H; Gordon, Michael H; John, Philip; Lovegrove, Julie A; Vysini, Eleni; Wagstaffe, Alexandra; Hadley, Paul

    2012-06-01

    Strawberry (Fragaria × ananassa Duchesne var. Elsanta) plants were grown in polytunnels covered with three polythene films that transmitted varying levels of ultraviolet (UV) light. Fruit were harvested under near-commercial conditions and quality and yield were measured. During ripening, changes in the colour parameters of individual fruit were monitored, and the accuracy of using surface colour to predict other quality parameters was determined by analysing the correlation between colour and quality parameters within UV treatments. Higher exposure to UV during growth resulted in the fruit becoming darker at harvest and developing surface colour more quickly; fruit were also firmer at harvest, but shelf life was not consistently affected by the UV regime. Surface colour measurements were poorly correlated to firmness, shelf life or total phenolics, anthocyanins and ellagic acid contents. Although surface colour of strawberry fruits was affected by the UV regime during growth, and this parameter is an important factor in consumer perception, we concluded that the surface colour at the time of harvest was, contrary to consumer expectations, a poor indicator of firmness, potential shelf life or anthocyanin content. Copyright © 2011 Society of Chemical Industry.

  15. Effectiveness of birds, butterflies, dragonflies, damselflies and invertebrates as indicators of freshwater ecological integrity

    NASA Astrophysics Data System (ADS)

    Chama, Lackson; Siachoono, Stanford

    2015-04-01

    Human activities such as mining and agriculture are among the major threats to biodiversity globally. Discharges from these activities have been shown to negatively affect ecological processes, leading to ecosystem degradation and species loss across biomes. Freshwater systems have been shown to be particularly vulnerable, as discharges tend to spread rapidly here than in other ecosystems. Hence, there is need to routinely monitor the quality of these systems if impacts of discharges from human activities are to be minimised. Besides the use of conventional laboratory techniques, several studies have recently shown that organisms such as birds, butterflies, dragonflies, damselflies and invertebrates are also good indicators of ecological integrity and should therefore be used as alternatives to monitoring the quality of various ecosystems. However, most of these studies have only studied one or two of these organisms against ecosystem health, and it remains unclear whether all of them respond similarly to changes in different drivers of environmental change. We investigated the response of the diversity of birds, butterflies, dragonflies, damselflies and invertebrates to changing water quality along the Kafue River in Zambia. Sampling was done at 13 different sampling points stretching over a distance of 60Km along the river. At each point, both the diversity of each organism and the water quality were assessed. Water quality was determined by testing its temperature, pH, redox, electrical conductivity, turbidity and copper parameters. We then tested how the diversity of each organism responded to changes in these water parameters. All water parameters varied significantly across sampling points. The diversity of birds and damselflies remained unaffected by any of the water parameters used. However, the diversity of butterflies reduced with increasing pH, turbidity and copper, albeit it remained unaffected by other water parameters. The diversity of dragonflies reduced with increasing redox, electrical conductivity and turbidity, but remained unaffected by other water parameters. The diversity of invertebrates reduced with increasing redox and copper, but remained unaffected by other water parameters. Generally, these results suggest that these organisms, especially butterflies, dragonflies and invertebrates can indeed be used as indicators of changing water quality and ecological integrity in particular. However, their use is limited to specific, rather than, all water parameters. Therefore, the decision as to which organisms to use should largely depend on which water quality parameters are to be tested. Key words: temperature; pH; redox; electrical conductivity; turbidity; copper

  16. Experiments for practical education in process parameter optimization for selective laser sintering to increase workpiece quality

    NASA Astrophysics Data System (ADS)

    Reutterer, Bernd; Traxler, Lukas; Bayer, Natascha; Drauschke, Andreas

    2016-04-01

    Selective Laser Sintering (SLS) is considered as one of the most important additive manufacturing processes due to component stability and its broad range of usable materials. However the influence of the different process parameters on mechanical workpiece properties is still poorly studied, leading to the fact that further optimization is necessary to increase workpiece quality. In order to investigate the impact of various process parameters, laboratory experiments are implemented to improve the understanding of the SLS limitations and advantages on an educational level. Experiments are based on two different workstations, used to teach students the fundamentals of SLS. First of all a 50 W CO2 laser workstation is used to investigate the interaction of the laser beam with the used material in accordance with varied process parameters to analyze a single-layered test piece. Second of all the FORMIGA P110 laser sintering system from EOS is used to print different 3D test pieces in dependence on various process parameters. Finally quality attributes are tested including warpage, dimension accuracy or tensile strength. For dimension measurements and evaluation of the surface structure a telecentric lens in combination with a camera is used. A tensile test machine allows testing of the tensile strength and the interpreting of stress-strain curves. The developed laboratory experiments are suitable to teach students the influence of processing parameters. In this context they will be able to optimize the input parameters depending on the component which has to be manufactured and to increase the overall quality of the final workpiece.

  17. Near real time water quality monitoring of Chivero and Manyame lakes of Zimbabwe

    NASA Astrophysics Data System (ADS)

    Muchini, Ronald; Gumindoga, Webster; Togarepi, Sydney; Pinias Masarira, Tarirai; Dube, Timothy

    2018-05-01

    Zimbabwe's water resources are under pressure from both point and non-point sources of pollution hence the need for regular and synoptic assessment. In-situ and laboratory based methods of water quality monitoring are point based and do not provide a synoptic coverage of the lakes. This paper presents novel methods for retrieving water quality parameters in Chivero and Manyame lakes, Zimbabwe, from remotely sensed imagery. Remotely sensed derived water quality parameters are further validated using in-situ data. It also presents an application for automated retrieval of those parameters developed in VB6, as well as a web portal for disseminating the water quality information to relevant stakeholders. The web portal is developed, using Geoserver, open layers and HTML. Results show the spatial variation of water quality and an automated remote sensing and GIS system with a web front end to disseminate water quality information.

  18. Assessment and modeling of groundwater quality using WQI and GIS in Upper Egypt area.

    PubMed

    Rabeiy, Ragab ElSayed

    2017-04-04

    The continuous growth and development of population need more fresh water for drinking, irrigation, and domestic in arid countries like Egypt. Evaluation the quality of groundwater is an essential study to ensure its suitability for different purposes. In this study, 812 groundwater samples were taken within the middle area of Upper Egypt (Sohag Governorate) to assess the quality of groundwater for drinking and irrigation purposes. Eleven water parameters were analyzed at each groundwater sample (Na + , K + , Ca 2+ , Mg 2+ , HCO 3 - SO 4 2- , Fe 2+ , Mn 2+ , Cl - , electrical conductivity, and pH) to exploit them in water quality evaluation. A classical statistics were applied for the raw data to examine the distribution of physicochemical parameters in the investigated area. The relationship between groundwater parameters was tested using the correlation coefficient where a strong relationship was found between several water parameters such as Ca 2+ and Cl - . Water quality index (WQI) is a mathematical model used to transform many water parameters into a single indicator value which represents the water quality level. Results of WQI showed that 20% of groundwater samples are excellent, 75% are good for drinking, and 7% are very poor water while only 1% of samples are unsuitable for drinking. To test the suitability of groundwater for irrigation, three indices are used; they are sodium adsorption ration (SAR), sodium percentage (Na%), and permeability index (PI). For irrigation suitability, the study proved that most sampling sites are suitable while less than 3% are unsuitable for irrigation. The spatial distribution of the estimated values of WQI, SAR, Na%, PI, and each groundwater parameter was spatially modeled using GIS.

  19. A systematic approach to evaluate parameter consistency in the inlet stream of source separated biowaste composting facilities: A case study in Colombia.

    PubMed

    Oviedo-Ocaña, E R; Torres-Lozada, P; Marmolejo-Rebellon, L F; Torres-López, W A; Dominguez, I; Komilis, D; Sánchez, A

    2017-04-01

    Biowaste is commonly the largest fraction of municipal solid waste (MSW) in developing countries. Although composting is an effective method to treat source separated biowaste (SSB), there are certain limitations in terms of operation, partly due to insufficient control to the variability of SSB quality, which affects process kinetics and product quality. This study assesses the variability of the SSB physicochemical quality in a composting facility located in a small town of Colombia, in which SSB collection was performed twice a week. Likewise, the influence of the SSB physicochemical variability on the variability of compost parameters was assessed. Parametric and non-parametric tests (i.e. Student's t-test and the Mann-Whitney test) showed no significant differences in the quality parameters of SSB among collection days, and therefore, it was unnecessary to establish specific operation and maintenance regulations for each collection day. Significant variability was found in eight of the twelve quality parameters analyzed in the inlet stream, with corresponding coefficients of variation (CV) higher than 23%. The CVs for the eight parameters analyzed in the final compost (i.e. pH, moisture, total organic carbon, total nitrogen, C/N ratio, total phosphorus, total potassium and ash) ranged from 9.6% to 49.4%, with significant variations in five of those parameters (CV>20%). The above indicate that variability in the inlet stream can affect the variability of the end-product. Results suggest the need to consider variability of the inlet stream in the performance of composting facilities to achieve a compost of consistent quality. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Parameters of Technological Growth

    ERIC Educational Resources Information Center

    Starr, Chauncey; Rudman, Richard

    1973-01-01

    Examines the factors involved in technological growth and identifies the key parameters as societal resources and societal expectations. Concludes that quality of life can only be maintained by reducing population growth, since this parameter is the product of material levels, overcrowding, food, and pollution. (JR)

  1. Application of LANDSAT to the Surveillance and Control of Eutrophication in Saginaw Bay

    NASA Technical Reports Server (NTRS)

    Rogers, R. H. (Principal Investigator)

    1975-01-01

    The author has identified the following significant results. LANDSAT digital data and ground truth measurements for Saginaw Bay (Lake Huron), Michigan, for 3 June 1974 can be correlated by stepwise linear regression technique and the resulting equations used to estimate invisible water quality parameters in nonsampled areas. Correlation of these parameters with each other indicates that the transport of Saginaw River water can now be traced by a number of water quality features, one or more of which are directly detected by LANDSAT. Five of the 12 water quality parameters are best correlated with LANDSAT band 6 measurements alone. One parameter (temperature) relates to band 5 alone and the remaining six may be predicted with varying degrees of accuracy from a combination of two bands (first band 6 and generally band 4 second).

  2. Owner perceptions of their cat's quality of life when treated with a modified University of Wisconsin-Madison protocol for lymphoma.

    PubMed

    Thornton, Laura A; Cave, Nicholas; Bridges, Janis P; Stell, Anneliese J

    2018-04-01

    Objectives The objectives of this study were to assess owner perceptions of their cat's quality of life during treatment for lymphoma with a doxorubicin-containing multi-agent chemotherapy protocol, whether various health-related parameters correlated with quality of life scores, and to assess owner satisfaction with the protocol. Methods A postal questionnaire was sent to the owners of 33 treated cats. Owners retrospectively assessed their cat's quality of life using a Likert scale (1-10) before lymphoma was diagnosed, at diagnosis and during chemotherapy. Owners assigned scores to various health-related parameters previously reported to affect quality of life at the three time points, and correlations with quality of life scores were sought. Owners were asked to rate the importance of these health-related parameters. Satisfaction with the protocol was investigated. Results Twenty questionnaires were completed (61% response rate). The median quality of life score before diagnosis (10, range 5-10) was higher than at diagnosis (3, range 1-9) ( P <0.05). The median quality of life score during chemotherapy (7, range 3-9) was lower than before diagnosis ( P <0.05) and higher than at diagnosis, but this was not statistically significant. Quality of life scores did not correlate with individual health-related parameter scores consistently; however, quality of life scores did correlate with appetite scores during chemotherapy. Appetite, vomiting and diarrhoea were parameters perceived as important in affecting quality of life. Most owners (75%) were happy they had treated their cat. Conclusions and relevance The quality of life scores observed were comparable to a previous study using cyclophosphamide, vincristine and prednisolone, employing the same scoring system. Although quality of life scores during chemotherapy were not significantly improved at diagnosis, owner satisfaction with the protocol was high. The factors perceived by owners to determine quality of life in their pets may be different to those previously conjectured, but appetite during chemotherapy remains important.

  3. Physical activity is not related to semen quality in young healthy men

    PubMed Central

    Mínguez-Alarcón, Lidia; Chavarro, Jorge E; Mendiola, Jaime; Gaskins, Audrey J; Torres-Cantero, Alberto M

    2015-01-01

    Objective To study the relation of physical activity with semen quality among healthy young men from Spain. Design Cross-sectional study. Setting University and college campuses of Murcia Region, Spain. Patients Healthy young men with untested fertility (n=215). Intervention A physical examination, blood and semen samples, and completion of a questionnaire. Main outcomes measure Semen quality parameters. Results Physical activity was not related to semen quality parameters. The adjusted percentage differences (95% confidence interval) in semen parameters comparing men in the top quartile of moderate to vigorous physical activity (≥9.5h/wk) to men in the bottom quartile (≤3h/wk) were 4.3% (−30.2, 38.9) for total sperm count, 7.2% (−30.6, 45.1) for sperm concentration, −2.42% (−6.53, 1.69) for sperm motility, and 12.6% (−12.0, 37.2) for sperm morphology. Conclusion In contrast to previous research among athletes, these data suggest that physical activity is not deleterious to testicular function, as captured by semen quality parameters in this population of healthy young men in Spain. PMID:25064411

  4. Application of Quality by Design to the characterization of the cell culture process of an Fc-Fusion protein.

    PubMed

    Rouiller, Yolande; Solacroup, Thomas; Deparis, Véronique; Barbafieri, Marco; Gleixner, Ralf; Broly, Hervé; Eon-Duval, Alex

    2012-06-01

    The production bioreactor step of an Fc-Fusion protein manufacturing cell culture process was characterized following Quality by Design principles. Using scientific knowledge derived from the literature and process knowledge gathered during development studies and manufacturing to support clinical trials, potential critical and key process parameters with a possible impact on product quality and process performance, respectively, were determined during a risk assessment exercise. The identified process parameters were evaluated using a design of experiment approach. The regression models generated from the data allowed characterizing the impact of the identified process parameters on quality attributes. The main parameters having an impact on product titer were pH and dissolved oxygen, while those having the highest impact on process- and product-related impurities and variants were pH and culture duration. The models derived from characterization studies were used to define the cell culture process design space. The design space limits were set in such a way as to ensure that the drug substance material would consistently have the desired quality. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Physical activity is not related to semen quality in young healthy men.

    PubMed

    Mínguez-Alarcón, Lidia; Chavarro, Jorge E; Mendiola, Jaime; Gaskins, Audrey J; Torres-Cantero, Alberto M

    2014-10-01

    To study the relationship of physical activity with semen quality among healthy young men from Spain. Cross-sectional study. University and college campuses of Murcia Region, Spain. Healthy young men with untested fertility (n = 215). A physical examination, blood and semen samples, and completion of a questionnaire. Semen quality parameters. Physical activity was not related to semen quality parameters. The adjusted percentage differences (95% confidence interval) in semen parameters comparing men in the top quartile of moderate-to-vigorous physical activity (≥9.5 h/wk) with men in the bottom quartile (≤3 h/wk) were 4.3% (-30.2%, 38.9%) for total sperm count, 7.2% (-30.6%, 45.1%) for sperm concentration, -2.42% (-6.53%, 1.69%) for sperm motility, and 12.6% (-12.0%, 37.2%) for sperm morphology. In contrast to previous research among athletes, these data suggest that physical activity is not deleterious to testicular function, as captured by semen quality parameters in this population of healthy young men in Spain. Copyright © 2014 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  6. Research on Product Conceptual Design Based on Integrated of TRIZ and HOQ

    NASA Astrophysics Data System (ADS)

    Xie, Jianmin; Tang, Xiaowo; Shao, Yunfei

    The conceptual design determines the success of the final product quality and competition of market. The determination of design parameters and the effective method to resolve parameters contradiction are the key to success. In this paper, the concept of HOQ products designed to determine the parameters, then using the TRIZ contradiction matrix and inventive principles of design parameters to solve the problem of contradictions. Facts have proved that the effective method is to obtain the product concept design parameters and to resolve contradictions line parameters.

  7. OHIO RIVER WATER QUALITY ASSESSMENT USING LANDSAT-7 DATA

    EPA Science Inventory

    The objectives of this project were (1) to develop a universal index for measuring Turbidity and Chlorophyll-A from remote sensing data and (2) to correlate satellite image parameters from Landsat-7 data with field measurements of water quality for five parameters: Chlorophyll-A ...

  8. Development and system identification of a light unmanned aircraft for flying qualities research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peters, M.E.; Andrisani, D. II

    This paper describes the design, construction, flight testing and system identification of a light weight remotely piloted aircraft and its use in studying flying qualities in the longitudinal axis. The short period approximation to the longitudinal dynamics of the aircraft was used. Parameters in this model were determined a priori using various empirical estimators. These parameters were then estimated from flight data using a maximum likelihood parameter identification method. A comparison of the parameter values revealed that the stability derivatives obtained from the empirical estimators were reasonably close to the flight test results. However, the control derivatives determined by themore » empirical estimators were too large by a factor of two. The aircraft was also flown to determine how the longitudinal flying qualities of light weight remotely piloted aircraft compared to full size manned aircraft. It was shown that light weight remotely piloted aircraft require much faster short period dynamics to achieve level I flying qualities in an up-and-away flight task.« less

  9. Simultaneous determination of phthalates, their metabolites, alkylphenols and bisphenol A using GC-MS in urine of men with fertility problems.

    PubMed

    Kranvogl, Roman; Knez, Jure; Miuc, Alen; Vončina, Ernest; Vončina, Darinka Brodnjak; Vlaisavljević, Veljko

    2014-01-01

    A GC-MS method was successfully applied to measure simultaneously the concentrations of endocrine disrupting compounds (5 dialkyl phthalates, 9 phthalate monoesters, 3 alkylphenols and bisphenol A) in 136 male urine samples. In the present study the method was validated and concentrations of EDCs were determined. The results were compared with results from other studies. Correlations between endocrine disrupting compounds and also correlations of endocrine disrupting compounds with two semen quality parameters are presented and evaluated. Significant positive correlations were found between almost all the endocrine disrupting compounds. The parameter sum of DEHP (SUM DEHP) was positively correlated to all the endocrine disrupting compounds but negatively to two semen quality parameters. Negative correlations between the endocrine disrupting compounds and the semen quality parameters could indicate that endocrine disrupting compounds could cause reproductive problems by decreasing the semen count and quality. This research will have helped to evaluate human exposure to endocrine disrupting compounds.

  10. Identifying key sources of uncertainty in the modelling of greenhouse gas emissions from wastewater treatment.

    PubMed

    Sweetapple, Christine; Fu, Guangtao; Butler, David

    2013-09-01

    This study investigates sources of uncertainty in the modelling of greenhouse gas emissions from wastewater treatment, through the use of local and global sensitivity analysis tools, and contributes to an in-depth understanding of wastewater treatment modelling by revealing critical parameters and parameter interactions. One-factor-at-a-time sensitivity analysis is used to screen model parameters and identify those with significant individual effects on three performance indicators: total greenhouse gas emissions, effluent quality and operational cost. Sobol's method enables identification of parameters with significant higher order effects and of particular parameter pairs to which model outputs are sensitive. Use of a variance-based global sensitivity analysis tool to investigate parameter interactions enables identification of important parameters not revealed in one-factor-at-a-time sensitivity analysis. These interaction effects have not been considered in previous studies and thus provide a better understanding wastewater treatment plant model characterisation. It was found that uncertainty in modelled nitrous oxide emissions is the primary contributor to uncertainty in total greenhouse gas emissions, due largely to the interaction effects of three nitrogen conversion modelling parameters. The higher order effects of these parameters are also shown to be a key source of uncertainty in effluent quality. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Effects of melody and technique on acoustical and musical features of western operatic singing voices.

    PubMed

    Larrouy-Maestri, Pauline; Magis, David; Morsomme, Dominique

    2014-05-01

    The operatic singing technique is frequently used in classical music. Several acoustical parameters of this specific technique have been studied but how these parameters combine remains unclear. This study aims to further characterize the Western operatic singing technique by observing the effects of melody and technique on acoustical and musical parameters of the singing voice. Fifty professional singers performed two contrasting melodies (popular song and romantic melody) with two vocal techniques (with and without operatic singing technique). The common quality parameters (energy distribution, vibrato rate, and extent), perturbation parameters (standard deviation of the fundamental frequency, signal-to-noise ratio, jitter, and shimmer), and musical features (fundamental frequency of the starting note, average tempo, and sound pressure level) of the 200 sung performances were analyzed. The results regarding the effect of melody and technique on the acoustical and musical parameters show that the choice of melody had a limited impact on the parameters observed, whereas a particular vocal profile appeared depending on the vocal technique used. This study confirms that vocal technique affects most of the parameters examined. In addition, the observation of quality, perturbation, and musical parameters contributes to a better understanding of the Western operatic singing technique. Copyright © 2014 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  12. Optimisation of shock absorber process parameters using failure mode and effect analysis and genetic algorithm

    NASA Astrophysics Data System (ADS)

    Mariajayaprakash, Arokiasamy; Senthilvelan, Thiyagarajan; Vivekananthan, Krishnapillai Ponnambal

    2013-07-01

    The various process parameters affecting the quality characteristics of the shock absorber during the process were identified using the Ishikawa diagram and by failure mode and effect analysis. The identified process parameters are welding process parameters (squeeze, heat control, wheel speed, and air pressure), damper sealing process parameters (load, hydraulic pressure, air pressure, and fixture height), washing process parameters (total alkalinity, temperature, pH value of rinsing water, and timing), and painting process parameters (flowability, coating thickness, pointage, and temperature). In this paper, the process parameters, namely, painting and washing process parameters, are optimized by Taguchi method. Though the defects are reasonably minimized by Taguchi method, in order to achieve zero defects during the processes, genetic algorithm technique is applied on the optimized parameters obtained by Taguchi method.

  13. Inverse modeling with RZWQM2 to predict water quality

    USDA-ARS?s Scientific Manuscript database

    Agricultural systems models such as RZWQM2 are complex and have numerous parameters that are unknown and difficult to estimate. Inverse modeling provides an objective statistical basis for calibration that involves simultaneous adjustment of model parameters and yields parameter confidence intervals...

  14. Swift Foxes and Ideal Free Distribution: Relative Influence of Vegetation and Rodent Prey Base on Swift Fox Survival, Density, and Home Range Size

    DTIC Science & Technology

    2012-01-01

    of exploiting a wide range of habitats, reported population parameters such as density and survival vary widely indicating variation in habitat quality...more strongly influenced by the “riskiness” of the habitat than by resource availability [8]. Swift fox population parameters in different landscapes...we explored the effects of landscape heterogeneity on population parameters likely to reflect habitat quality, such as population density, home range

  15. Systems for monitoring and digitally recording water-quality parameters

    USGS Publications Warehouse

    Smoot, George F.; Blakey, James F.

    1966-01-01

    Digital recording of water-quality parameters is a link in the automated data collection and processing system of the U.S. Geological Survey. The monitoring and digital recording systems adopted by the Geological Survey, while punching all measurements on a standard paper tape, provide a choice of compatible components to construct a system to meet specific physical problems and data needs. As many as 10 parameters can be recorded by an Instrument, with the only limiting criterion being that measurements are expressed as electrical signals.

  16. Decadal water quality variations at three typical basins of Mekong, Murray and Yukon

    NASA Astrophysics Data System (ADS)

    Khan, Afed U.; Jiang, Jiping; Wang, Peng

    2018-02-01

    Decadal distribution of water quality parameters is essential for surface water management. Decadal distribution analysis was conducted to assess decadal variations in water quality parameters at three typical watersheds of Murray, Mekong and Yukon. Right distribution shifts were observed for phosphorous and nitrogen parameters at the Mekong watershed monitoring sites while left shifts were noted at the Murray and Yukon monitoring sites. Nutrients pollution increases with time at the Mekong watershed while decreases at the Murray and Yukon watershed monitoring stations. The results implied that watershed located in densely populated developing area has higher risk of water quality deterioration in comparison to thinly populated developed area. The present study suggests best management practices at watershed scale to modulate water pollution.

  17. Mapping of fluoride endemic areas and correlation studies of fluoride with other quality parameters of drinking water of Veppanapalli block of Dharmapuri district in Tamil Nadu.

    PubMed

    Karthikeyan, G; Sundarraj, A Shunmuga; Elango, K P

    2003-10-01

    193 drinking water samples from water sources of 27 panchayats of Veppanapalli block of Dharmapuri district of Tamil Nadu were analysed for chemical quality parameters. Based on the fluoride content of the water sources, fluoride maps differentiating regions with high / low fluoride levels were prepared using Isopleth mapping technique. The interdependence among the important chemical quality parameters were assessed using correlation studies. The experimental results of the application of linear and multiple regression equations on the influence of hardness, alkalinity, total dissolved solids and pH on fluoride are discussed.

  18. Impact of initial surface parameters on the final quality of laser micro-polished surfaces

    NASA Astrophysics Data System (ADS)

    Chow, Michael; Bordatchev, Evgueni V.; Knopf, George K.

    2012-03-01

    Laser micro-polishing (LμP) is a new laser-based microfabrication technology for improving surface quality during a finishing operation and for producing parts and surfaces with near-optical surface quality. The LμP process uses low power laser energy to melt a thin layer of material on the previously machined surface. The polishing effect is achieved as the molten material in the laser-material interaction zone flows from the elevated regions to the local minimum due to surface tension. This flow of molten material then forms a thin ultra-smooth layer on the top surface. The LμP is a complex thermo-dynamic process where the melting, flow and redistribution of molten material is significantly influenced by a variety of process parameters related to the laser, the travel motions and the material. The goal of this study is to analyze the impact of initial surface parameters on the final surface quality. Ball-end micromilling was used for preparing initial surface of samples from H13 tool steel that were polished using a Q-switched Nd:YAG laser. The height and width of micromilled scallops (waviness) were identified as dominant parameter affecting the quality of the LμPed surface. By adjusting process parameters, the Ra value of a surface, having a waviness period of 33 μm and a peak-to-valley value of 5.9 μm, was reduced from 499 nm to 301 nm, improving the final surface quality by 39.7%.

  19. Parameters of Higher Education Quality Assessment System at Universities

    ERIC Educational Resources Information Center

    Savickiene, Izabela

    2005-01-01

    The article analyses the system of institutional quality assessment at universities and lays foundation to its functional, morphological and processual parameters. It also presents the concept of the system and discusses the distribution of systems into groups, defines information, accountability, improvement and benchmarking functions of higher…

  20. The quality estimation of exterior wall’s and window filling’s construction design

    NASA Astrophysics Data System (ADS)

    Saltykov, Ivan; Bovsunovskaya, Maria

    2017-10-01

    The article reveals the term of “artificial envelope” in dwelling building. Authors offer a complex multifactorial approach to the design quality estimation of external fencing structures, which is based on various parameters impact. These referred parameters are: functional, exploitation, cost, and also, the environmental index is among them. The quality design index Qк is inputting for the complex characteristic of observed above parameters. The mathematical relation of this index from these parameters is the target function for the quality design estimation. For instance, the article shows the search of optimal variant for wall and window designs in small, middle and large square dwelling premises of economic class buildings. The graphs of target function single parameters are expressed for the three types of residual chamber’s dimensions. As a result of the showing example, there is a choice of window opening’s dimensions, which make the wall’s and window’s constructions properly correspondent to the producible complex requirements. The authors reveal the comparison of recommended window filling’s square in accordance with the building standards, and the square, due to the finding of the optimal variant of the design quality index. The multifactorial approach for optimal design searching, which is mentioned in this article, can be used in consideration of various construction elements of dwelling buildings in accounting of suitable climate, social and economic construction area features.

  1. Application of a newly developed software program for image quality assessment in cone-beam computed tomography.

    PubMed

    de Oliveira, Marcus Vinicius Linhares; Santos, António Carvalho; Paulo, Graciano; Campos, Paulo Sergio Flores; Santos, Joana

    2017-06-01

    The purpose of this study was to apply a newly developed free software program, at low cost and with minimal time, to evaluate the quality of dental and maxillofacial cone-beam computed tomography (CBCT) images. A polymethyl methacrylate (PMMA) phantom, CQP-IFBA, was scanned in 3 CBCT units with 7 protocols. A macro program was developed, using the free software ImageJ, to automatically evaluate the image quality parameters. The image quality evaluation was based on 8 parameters: uniformity, the signal-to-noise ratio (SNR), noise, the contrast-to-noise ratio (CNR), spatial resolution, the artifact index, geometric accuracy, and low-contrast resolution. The image uniformity and noise depended on the protocol that was applied. Regarding the CNR, high-density structures were more sensitive to the effect of scanning parameters. There were no significant differences between SNR and CNR in centered and peripheral objects. The geometric accuracy assessment showed that all the distance measurements were lower than the real values. Low-contrast resolution was influenced by the scanning parameters, and the 1-mm rod present in the phantom was not depicted in any of the 3 CBCT units. Smaller voxel sizes presented higher spatial resolution. There were no significant differences among the protocols regarding artifact presence. This software package provided a fast, low-cost, and feasible method for the evaluation of image quality parameters in CBCT.

  2. Temporal performance assessment of wastewater treatment plants by using multivariate statistical analysis.

    PubMed

    Ebrahimi, Milad; Gerber, Erin L; Rockaway, Thomas D

    2017-05-15

    For most water treatment plants, a significant number of performance data variables are attained on a time series basis. Due to the interconnectedness of the variables, it is often difficult to assess over-arching trends and quantify operational performance. The objective of this study was to establish simple and reliable predictive models to correlate target variables with specific measured parameters. This study presents a multivariate analysis of the physicochemical parameters of municipal wastewater. Fifteen quality and quantity parameters were analyzed using data recorded from 2010 to 2016. To determine the overall quality condition of raw and treated wastewater, a Wastewater Quality Index (WWQI) was developed. The index summarizes a large amount of measured quality parameters into a single water quality term by considering pre-established quality limitation standards. To identify treatment process performance, the interdependencies between the variables were determined by using Principal Component Analysis (PCA). The five extracted components from the 15 variables accounted for 75.25% of total dataset information and adequately represented the organic, nutrient, oxygen demanding, and ion activity loadings of influent and effluent streams. The study also utilized the model to predict quality parameters such as Biological Oxygen Demand (BOD), Total Phosphorus (TP), and WWQI. High accuracies ranging from 71% to 97% were achieved for fitting the models with the training dataset and relative prediction percentage errors less than 9% were achieved for the testing dataset. The presented techniques and procedures in this paper provide an assessment framework for the wastewater treatment monitoring programs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. METHODOLOGIES FOR CALIBRATION AND PREDICTIVE ANALYSIS OF A WATERSHED MODEL

    EPA Science Inventory

    The use of a fitted-parameter watershed model to address water quantity and quality management issues requires that it be calibrated under a wide range of hydrologic conditions. However, rarely does model calibration result in a unique parameter set. Parameter nonuniqueness can l...

  4. Impacts of climate change on surface water quality in relation to drinking water production.

    PubMed

    Delpla, I; Jung, A-V; Baures, E; Clement, M; Thomas, O

    2009-11-01

    Besides climate change impacts on water availability and hydrological risks, the consequences on water quality is just beginning to be studied. This review aims at proposing a synthesis of the most recent existing interdisciplinary literature on the topic. After a short presentation about the role of the main factors (warming and consequences of extreme events) explaining climate change effects on water quality, the focus will be on two main points. First, the impacts on water quality of resources (rivers and lakes) modifying parameters values (physico-chemical parameters, micropollutants and biological parameters) are considered. Then, the expected impacts on drinking water production and quality of supplied water are discussed. The main conclusion which can be drawn is that a degradation trend of drinking water quality in the context of climate change leads to an increase of at risk situations related to potential health impact.

  5. Influence of scanning parameters on the estimation accuracy of control points of B-spline surfaces

    NASA Astrophysics Data System (ADS)

    Aichinger, Julia; Schwieger, Volker

    2018-04-01

    This contribution deals with the influence of scanning parameters like scanning distance, incidence angle, surface quality and sampling width on the average estimated standard deviations of the position of control points from B-spline surfaces which are used to model surfaces from terrestrial laser scanning data. The influence of the scanning parameters is analyzed by the Monte Carlo based variance analysis. The samples were generated for non-correlated and correlated data, leading to the samples generated by Latin hypercube and replicated Latin hypercube sampling algorithms. Finally, the investigations show that the most influential scanning parameter is the distance from the laser scanner to the object. The angle of incidence shows a significant effect for distances of 50 m and longer, while the surface quality contributes only negligible effects. The sampling width has no influence. Optimal scanning parameters can be found in the smallest possible object distance at an angle of incidence close to 0° in the highest surface quality. The consideration of correlations improves the estimation accuracy and underlines the importance of complete stochastic models for TLS measurements.

  6. Application of LANDSAT to the surveillance and control of lake eutrophication in the Great Lakes basin. [Saginaw Bay, Michigan and Wisconsin

    NASA Technical Reports Server (NTRS)

    Rogers, R. H. (Principal Investigator)

    1976-01-01

    The author has identified the following significant results. Computer techniques were developed for mapping water quality parameters from LANDSAT data, using surface samples collected in an ongoing survey of water quality in Saginaw Bay. Chemical and biological parameters were measured on 31 July 1975 at 16 bay stations in concert with the LANDSAT overflight. Application of stepwise linear regression bands to nine of these parameters and corresponding LANDSAT measurements for bands 4 and 5 only resulted in regression correlation coefficients that varied from 0.94 for temperature to 0.73 for Secchi depth. Regression equations expressed with the pair of bands 4 and 5, rather than the ratio band 4/band 5, provided higher correlation coefficients for all the water quality parameters studied (temperature, Secchi depth, chloride, conductivity, total kjeldahl nitrogen, total phosphorus, chlorophyll a, total solids, and suspended solids).

  7. Scale Control and Quality Management of Printed Image Parameters

    NASA Astrophysics Data System (ADS)

    Novoselskaya, O. A.; Kolesnikov, V. L.; Solov'eva, T. V.; Nagornova, I. V.; Babluyk, E. B.; Trapeznikova, O. V.

    2017-06-01

    The article provides a comparison of the main valuation techniques for a regulated parameter of printability of the offset paper by current standards GOST 24356 and ISO 3783: 2006. The results of development and implementation of a complex test scale for management and control the quality of printed production are represented. The estimation scale is introduced. It includes normalized parameters of print optical density, print uniformity, picking out speed, the value of dot gain, print contrast with the added criteria of minimizing microtexts, a paper slip, resolution threshold and effusing ability of paper surface. The results of analysis allow directionally form surface properties of the substrate to facilitate achieving the required quality of the printed image parameters, i. e. optical density of a print at a predetermined level not less than 1.3, the print uniformity with minimal deviation of dot gain about the order of 10 per cents.

  8. Descriptive Characteristics of Surface Water Quality in Hong Kong by a Self-Organising Map

    PubMed Central

    An, Yan; Zou, Zhihong; Li, Ranran

    2016-01-01

    In this study, principal component analysis (PCA) and a self-organising map (SOM) were used to analyse a complex dataset obtained from the river water monitoring stations in the Tolo Harbor and Channel Water Control Zone (Hong Kong), covering the period of 2009–2011. PCA was initially applied to identify the principal components (PCs) among the nonlinear and complex surface water quality parameters. SOM followed PCA, and was implemented to analyze the complex relationships and behaviors of the parameters. The results reveal that PCA reduced the multidimensional parameters to four significant PCs which are combinations of the original ones. The positive and inverse relationships of the parameters were shown explicitly by pattern analysis in the component planes. It was found that PCA and SOM are efficient tools to capture and analyze the behavior of multivariable, complex, and nonlinear related surface water quality data. PMID:26761018

  9. Descriptive Characteristics of Surface Water Quality in Hong Kong by a Self-Organising Map.

    PubMed

    An, Yan; Zou, Zhihong; Li, Ranran

    2016-01-08

    In this study, principal component analysis (PCA) and a self-organising map (SOM) were used to analyse a complex dataset obtained from the river water monitoring stations in the Tolo Harbor and Channel Water Control Zone (Hong Kong), covering the period of 2009-2011. PCA was initially applied to identify the principal components (PCs) among the nonlinear and complex surface water quality parameters. SOM followed PCA, and was implemented to analyze the complex relationships and behaviors of the parameters. The results reveal that PCA reduced the multidimensional parameters to four significant PCs which are combinations of the original ones. The positive and inverse relationships of the parameters were shown explicitly by pattern analysis in the component planes. It was found that PCA and SOM are efficient tools to capture and analyze the behavior of multivariable, complex, and nonlinear related surface water quality data.

  10. Use of the Plasma Spectrum RMS Signal for Arc-Welding Diagnostics.

    PubMed

    Mirapeix, Jesus; Cobo, Adolfo; Fuentes, Jose; Davila, Marta; Etayo, Juan Maria; Lopez-Higuera, Jose-Miguel

    2009-01-01

    A new spectroscopic parameter is used in this paper for on-line arc-welding quality monitoring. Plasma spectroscopy applied to welding diagnostics has typically relied on the estimation of the plasma electronic temperature, as there is a known correlation between this parameter and the quality of the seams. However, the practical use of this parameter gives rise to some uncertainties that could provoke ambiguous results. For an efficient on-line welding monitoring system, it is essential to prevent the appearance of false alarms, as well as to detect all the possible defects. In this regard, we propose the use of the root mean square signal of the welding plasma spectra, as this parameter will be proven to exhibit a good correlation with the quality of the resulting seams. Results corresponding to several arc-welding field tests performed on Inconel and titanium specimens will be discussed and compared to non-destructive evaluation techniques.

  11. Use of the Plasma Spectrum RMS Signal for Arc-Welding Diagnostics

    PubMed Central

    Mirapeix, Jesus; Cobo, Adolfo; Fuentes, Jose; Davila, Marta; Etayo, Juan Maria; Lopez-Higuera, Jose-Miguel

    2009-01-01

    A new spectroscopic parameter is used in this paper for on-line arc-welding quality monitoring. Plasma spectroscopy applied to welding diagnostics has typically relied on the estimation of the plasma electronic temperature, as there is a known correlation between this parameter and the quality of the seams. However, the practical use of this parameter gives rise to some uncertainties that could provoke ambiguous results. For an efficient on-line welding monitoring system, it is essential to prevent the appearance of false alarms, as well as to detect all the possible defects. In this regard, we propose the use of the root mean square signal of the welding plasma spectra, as this parameter will be proven to exhibit a good correlation with the quality of the resulting seams. Results corresponding to several arc-welding field tests performed on Inconel and titanium specimens will be discussed and compared to non-destructive evaluation techniques. PMID:22346696

  12. Aggregate R-R-V Analysis

    EPA Pesticide Factsheets

    The excel file contains time series data of flow rates, concentrations of alachlor , atrazine, ammonia, total phosphorus, and total suspended solids observed in two watersheds in Indiana from 2002 to 2007. The aggregate time series data corresponding or representative to all these parameters was obtained using a specialized, data-driven technique. The aggregate data is hypothesized in the published paper to represent the overall health of both watersheds with respect to various potential water quality impairments. The time series data for each of the individual water quality parameters were used to compute corresponding risk measures (Rel, Res, and Vul) that are reported in Table 4 and 5. The aggregation of the risk measures, which is computed from the aggregate time series and water quality standards in Table 1, is also reported in Table 4 and 5 of the published paper. Values under column heading uncertainty reports uncertainties associated with reconstruction of missing records of the water quality parameters. Long-term records of the water quality parameters were reconstructed in order to estimate the (R-R-V) and corresponding aggregate risk measures. This dataset is associated with the following publication:Hoque, Y., S. Tripathi, M. Hantush , and R. Govindaraju. Aggregate Measures of Watershed Health from Reconstructed Water Quality Data with Uncertainty. Ed Gregorich JOURNAL OF ENVIRONMENTAL QUALITY. American Society of Agronomy, MADISON, WI,

  13. Advanced Integrated Display System V/STOL Program Performance Specification. Volume I.

    DTIC Science & Technology

    1980-06-01

    sensor inputs required before the sensor can be designated acceptable. The reactivation count of each sensor parameter which satisfies its veri...129 3.5.2 AIDS Configuration Parameters .............. 133 3.5.3 AIDS Throughput Requirements ............... 133 4 QUALITY ASSURANCE...lists the adaptation parameters of the AIDS software; these parameters include the throughput and memory requirements of the software. 3.2 SYSTEM

  14. Effect of different concentrations of soybean lecithin and virgin coconut oil in Tris-based extender on the quality of chilled and frozen-thawed bull semen

    PubMed Central

    Tarig, A. A.; Wahid, H.; Rosnina, Y.; Yimer, N.; Goh, Y. M.; Baiee, F. H.; Khumran, A. M.; Salman, H.; Assi, M. A.; Ebrahimi, M.

    2017-01-01

    Aim: The objective of this study was to evaluate the effects of different concentrations of soybean lecithin (SL) and virgin coconut oil (VCO) in Tris-based extender on chilled and frozen-thawed bull semen quality parameters. Materials and Methods: A total of 24 ejaculates were collected from four bulls via an electroejaculator. Semen samples were diluted with 2% VCO in Tris-based extender which consists of various concentrations of SL (1, 1.25, 1.5, and 1.75%). A 20% egg yolk in Tris used as a positive control (C+). The diluted semen samples were divided into two fractions; one for chilling which were stored at 4°C for 24, 72, and 144 h before evaluated for semen quality parameters. The second fraction used for freezing was chilled for 3 h at 4°C, packed into 0.25 mL straws and then cryopreserved in liquid nitrogen. The samples were then evaluated after 7 and 14 days. Chilled and frozen semen samples were thawed at 37°C and assessed for general motility using computer-assisted semen analysis, viability, acrosome integrity and morphology (eosin-nigrosin stain), membrane integrity, and lipid peroxidation using thiobarbituric acid reaction test. Results: The results showed that all the quality parameters assessed were significantly (p<0.05) improved at 1.5% SL concentration in chilled semen. Treatment groups of 1, 1.25, 1.5, and 1.75% SL were higher in quality parameters than the control group (C+) in chilled semen. However, all the quality parameters in frozen-thawed semen were significantly higher in the C+ than the treated groups. Conclusion: In conclusion, supplementation of 1.5% SL in 2% VCO Tris-based extender enhanced the chilled bull semen. However, there was no marked improvement in the frozen-thawed quality parameters after treatment. PMID:28717321

  15. Effect of different concentrations of soybean lecithin and virgin coconut oil in Tris-based extender on the quality of chilled and frozen-thawed bull semen.

    PubMed

    Tarig, A A; Wahid, H; Rosnina, Y; Yimer, N; Goh, Y M; Baiee, F H; Khumran, A M; Salman, H; Assi, M A; Ebrahimi, M

    2017-06-01

    The objective of this study was to evaluate the effects of different concentrations of soybean lecithin (SL) and virgin coconut oil (VCO) in Tris-based extender on chilled and frozen-thawed bull semen quality parameters. A total of 24 ejaculates were collected from four bulls via an electroejaculator. Semen samples were diluted with 2% VCO in Tris-based extender which consists of various concentrations of SL (1, 1.25, 1.5, and 1.75%). A 20% egg yolk in Tris used as a positive control (C+). The diluted semen samples were divided into two fractions; one for chilling which were stored at 4°C for 24, 72, and 144 h before evaluated for semen quality parameters. The second fraction used for freezing was chilled for 3 h at 4°C, packed into 0.25 mL straws and then cryopreserved in liquid nitrogen. The samples were then evaluated after 7 and 14 days. Chilled and frozen semen samples were thawed at 37°C and assessed for general motility using computer-assisted semen analysis, viability, acrosome integrity and morphology (eosin-nigrosin stain), membrane integrity, and lipid peroxidation using thiobarbituric acid reaction test. The results showed that all the quality parameters assessed were significantly (p<0.05) improved at 1.5% SL concentration in chilled semen. Treatment groups of 1, 1.25, 1.5, and 1.75% SL were higher in quality parameters than the control group (C+) in chilled semen. However, all the quality parameters in frozen-thawed semen were significantly higher in the C+ than the treated groups. In conclusion, supplementation of 1.5% SL in 2% VCO Tris-based extender enhanced the chilled bull semen. However, there was no marked improvement in the frozen-thawed quality parameters after treatment.

  16. Water quality program elements for Space Station Freedom

    NASA Technical Reports Server (NTRS)

    Sauer, Richard L.; Ramanathan, Raghupathy; Straub, John E.; Schultz, John R.

    1991-01-01

    A strategy is outlined for the development of water-quality criteria and standards relevant to recycling and monitoring the in-flight water for the Space Station Freedom (SSF). The water-reclamation subsystem of the SSF's ECLSS is described, and the objectives of the water-quality are set forth with attention to contaminants. Quality parameters are listed for potable and hygiene-related water including physical and organic parameters, inorganic constituents, bactericides, and microbial content. Comparisons are made to the quality parameters established for the Shuttle's potable water and to the EPA's current standards. Specific research is required to develop in-flight monitoring techniques for unique SSF contaminants, ECLSS microbial control, and on- and off-line monitoring. After discussing some of the in-flight water-monitoring hardware it is concluded that water reclamation and recycling are necessary and feasible for the SSF.

  17. A Procedure for High Resolution Satellite Imagery Quality Assessment

    PubMed Central

    Crespi, Mattia; De Vendictis, Laura

    2009-01-01

    Data products generated from High Resolution Satellite Imagery (HRSI) are routinely evaluated during the so-called in-orbit test period, in order to verify if their quality fits the desired features and, if necessary, to obtain the image correction parameters to be used at the ground processing center. Nevertheless, it is often useful to have tools to evaluate image quality also at the final user level. Image quality is defined by some parameters, such as the radiometric resolution and its accuracy, represented by the noise level, and the geometric resolution and sharpness, described by the Modulation Transfer Function (MTF). This paper proposes a procedure to evaluate these image quality parameters; the procedure was implemented in a suitable software and tested on high resolution imagery acquired by the QuickBird, WorldView-1 and Cartosat-1 satellites. PMID:22412312

  18. Determining Sala mango qualities with the use of RGB images captured by a mobile phone camera

    NASA Astrophysics Data System (ADS)

    Yahaya, Ommi Kalsom Mardziah; Jafri, Mohd Zubir Mat; Aziz, Azlan Abdul; Omar, Ahmad Fairuz

    2015-04-01

    Sala mango (Mangifera indicia) is one of the Malaysia's most popular tropical fruits that are widely marketed within the country. The degrees of ripeness of mangoes have conventionally been evaluated manually on the basis of color parameters, but a simple non-destructive technique using the Samsung Galaxy Note 1 mobile phone camera is introduced to replace the destructive technique. In this research, color parameters in terms of RGB values acquired using the ENVI software system were linked to detect Sala mango quality parameters. The features of mango were extracted from the acquired images and then used to classify of fruit skin color, which relates to the stages of ripening. A multivariate analysis method, multiple linear regression, was employed with the purpose of using RGB color parameters to estimate the pH, soluble solids content (SSC), and firmness. The relationship between these qualities parameters of Sala mango and its mean pixel values in the RGB system is analyzed. Findings show that pH yields the highest accuracy with a correlation coefficient R = 0.913 and root mean square of error RMSE = 0.166 pH. Meanwhile, firmness has R = 0.875 and RMSE = 1.392 kgf, whereas soluble solid content has the lowest accuracy with R = 0.814 and RMSE = 1.218°Brix with the correlation between color parameters. Therefore, this non-invasive method can be used to determine the quality attributes of mangoes.

  19. EFFECTS OF AROMATHERAPY MASSAGE ON THE SLEEP QUALITY AND PHYSIOLOGICAL PARAMETERS OF PATIENTS IN A SURGICAL INTENSIVE CARE UNIT.

    PubMed

    Özlü, Zeynep Karaman; Bilican, Pınar

    2017-01-01

    Surgical pain is experienced by inpatients with clinical, disease-related concerns, unknown encounters after surgery, quality of sleep, restrictions in position after surgery is known to be serious. The study was conducted to determine the effect of aromatherapy massage on quality of sleep and physiological parameters in surgical intensive care patients. This is an experimental study. The sample of this study consisted of 60 patients who were divided into two groups as experimental group and control group including 30 patients in each one. The participants were postoperative patients, absent complications, who were unconscious and extubated. A data collection form on personal characteristics of the patients, a registration form on their physical parameters and the Richards-Campbell Sleep Scale (RCSQ) were used to collect the data of the study. The Richards-Campbell Sleep Scale indicated that while the experimental group had a mean score of 53.80 ± 13.20, the control group had a mean score of 29.08 ± 9.71 and there was a statistically significant difference between mean scores of the groups. In a comparison of physiologic parameters, only diastolic blood pressure measuring between parameters in favor of an assembly as a statistically significant difference was detected. Results of the study showed that aromatherapy massage enhanced the sleep quality of patients in a surgical intensive care unit and resulted in some positive changes in their physiological parameters.

  20. EFFECTS OF AROMATHERAPY MASSAGE ON THE SLEEP QUALITY AND PHYSIOLOGICAL PARAMETERS OF PATIENTS IN A SURGICAL INTENSIVE CARE UNIT

    PubMed Central

    Özlü, Zeynep Karaman; Bilican, Pınar

    2017-01-01

    Background: Surgical pain is experienced by inpatients with clinical, disease-related concerns, unknown encounters after surgery, quality of sleep, restrictions in position after surgery is known to be serious. The study was conducted to determine the effect of aromatherapy massage on quality of sleep and physiological parameters in surgical intensive care patients. Materials and Methods: This is an experimental study. The sample of this study consisted of 60 patients who were divided into two groups as experimental group and control group including 30 patients in each one. The participants were postoperative patients, absent complications, who were unconscious and extubated. A data collection form on personal characteristics of the patients, a registration form on their physical parameters and the Richards-Campbell Sleep Scale (RCSQ) were used to collect the data of the study. Results: The Richards-Campbell Sleep Scale indicated that while the experimental group had a mean score of 53.80 ± 13.20, the control group had a mean score of 29.08 ± 9.71 and there was a statistically significant difference between mean scores of the groups. In a comparison of physiologic parameters, only diastolic blood pressure measuring between parameters in favor of an assembly as a statistically significant difference was detected. Conclusions: Results of the study showed that aromatherapy massage enhanced the sleep quality of patients in a surgical intensive care unit and resulted in some positive changes in their physiological parameters. PMID:28480419

  1. Quality Assessment Parameters for Student Support at Higher Education Institutions

    ERIC Educational Resources Information Center

    Sajiene, Laima; Tamuliene, Rasa

    2012-01-01

    The research presented in this article aims to validate quality assessment parameters for student support at higher education institutions. Student support is discussed as the system of services provided by a higher education institution which helps to develop student-centred curriculum and fulfils students' emotional, academic, social needs, and…

  2. COUPLING HYPERSPECTRAL REMOTE SENSING WITH FIELD SPECTROMETRY TO MONITOR INLAND WATER QUALITY PARAMETERS

    EPA Science Inventory

    Visible to near-infrared, airborne hyperspectral data were successfully used to estimate water quality parameters such as chlorophyll a, turbidity and total phosphorus from the Great Miami River, Ohio. During the summer of 1999, spectral data were collected with a hand-held fiel...

  3. 40 CFR 141.87 - Monitoring requirements for water quality parameters.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... (c) Monitoring after installation of corrosion control. Any large system which installs optimal corrosion control treatment pursuant to § 141.81(d)(4) shall measure the water quality parameters at the...)(i). Any small or medium-size system which installs optimal corrosion control treatment shall conduct...

  4. 40 CFR 141.87 - Monitoring requirements for water quality parameters.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... (c) Monitoring after installation of corrosion control. Any large system which installs optimal corrosion control treatment pursuant to § 141.81(d)(4) shall measure the water quality parameters at the...)(i). Any small or medium-size system which installs optimal corrosion control treatment shall conduct...

  5. 40 CFR 141.87 - Monitoring requirements for water quality parameters.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... (c) Monitoring after installation of corrosion control. Any large system which installs optimal corrosion control treatment pursuant to § 141.81(d)(4) shall measure the water quality parameters at the...)(i). Any small or medium-size system which installs optimal corrosion control treatment shall conduct...

  6. 40 CFR 141.87 - Monitoring requirements for water quality parameters.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... (c) Monitoring after installation of corrosion control. Any large system which installs optimal corrosion control treatment pursuant to § 141.81(d)(4) shall measure the water quality parameters at the...)(i). Any small or medium-size system which installs optimal corrosion control treatment shall conduct...

  7. 40 CFR 141.87 - Monitoring requirements for water quality parameters.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... (c) Monitoring after installation of corrosion control. Any large system which installs optimal corrosion control treatment pursuant to § 141.81(d)(4) shall measure the water quality parameters at the...)(i). Any small or medium-size system which installs optimal corrosion control treatment shall conduct...

  8. Analysing the 21 cm signal from the epoch of reionization with artificial neural networks

    NASA Astrophysics Data System (ADS)

    Shimabukuro, Hayato; Semelin, Benoit

    2017-07-01

    The 21 cm signal from the epoch of reionization should be observed within the next decade. While a simple statistical detection is expected with Square Kilometre Array (SKA) pathfinders, the SKA will hopefully produce a full 3D mapping of the signal. To extract from the observed data constraints on the parameters describing the underlying astrophysical processes, inversion methods must be developed. For example, the Markov Chain Monte Carlo method has been successfully applied. Here, we test another possible inversion method: artificial neural networks (ANNs). We produce a training set that consists of 70 individual samples. Each sample is made of the 21 cm power spectrum at different redshifts produced with the 21cmFast code plus the value of three parameters used in the seminumerical simulations that describe astrophysical processes. Using this set, we train the network to minimize the error between the parameter values it produces as an output and the true values. We explore the impact of the architecture of the network on the quality of the training. Then we test the trained network on the new set of 54 test samples with different values of the parameters. We find that the quality of the parameter reconstruction depends on the sensitivity of the power spectrum to the different parameters at a given redshift, that including thermal noise and sample variance decreases the quality of the reconstruction and that using the power spectrum at several redshifts as an input to the ANN improves the quality of the reconstruction. We conclude that ANNs are a viable inversion method whose main strength is that they require a sparse exploration of the parameter space and thus should be usable with full numerical simulations.

  9. Projection of landfill stabilization period by time series analysis of leachate quality and transformation trends of VOCs.

    PubMed

    Sizirici, Banu; Tansel, Berrin

    2010-01-01

    The purpose of this study was to evaluate suitability of using the time series analysis for selected leachate quantity and quality parameters to forecast the duration of post closure period of a closed landfill. Selected leachate quality parameters (i.e., sodium, chloride, iron, bicarbonate, total dissolved solids (TDS), and ammonium as N) and volatile organic compounds (VOCs) (i.e., vinyl chloride, 1,4-dichlorobenzene, chlorobenzene, benzene, toluene, ethyl benzene, xylenes, total BTEX) were analyzed by the time series multiplicative decomposition model to estimate the projected levels of the parameters. These parameters were selected based on their detection levels and consistency of detection in leachate samples. In addition, VOCs detected in leachate and their chemical transformations were considered in view of the decomposition stage of the landfill. Projected leachate quality trends were analyzed and compared with the maximum contaminant level (MCL) for the respective parameters. Conditions that lead to specific trends (i.e., increasing, decreasing, or steady) and interactions of leachate quality parameters were evaluated. Decreasing trends were projected for leachate quantity, concentrations of sodium, chloride, TDS, ammonia as N, vinyl chloride, 1,4-dichlorobenzene, benzene, toluene, ethyl benzene, xylenes, and total BTEX. Increasing trends were projected for concentrations of iron, bicarbonate, and chlorobenzene. Anaerobic conditions in landfill provide favorable conditions for corrosion of iron resulting in higher concentrations over time. Bicarbonate formation as a byproduct of bacterial respiration during waste decomposition and the lime rock cap system of the landfill contribute to the increasing levels of bicarbonate in leachate. Chlorobenzene is produced during anaerobic biodegradation of 1,4-dichlorobenzene, hence, the increasing trend of chlorobenzene may be due to the declining trend of 1,4-dichlorobenzene. The time series multiplicative decomposition model in general provides an adequate forecast for future planning purposes for the parameters monitored in leachate. The model projections for 1,4-dichlorobenzene were relatively less accurate in comparison to the projections for vinyl chloride and chlorobenzene. Based on the trends observed, future monitoring needs for the selected leachate parameters were identified.

  10. Field spectrometer (S191H) preprocessor tape quality test program design document

    NASA Technical Reports Server (NTRS)

    Campbell, H. M.

    1976-01-01

    Program QA191H performs quality assurance tests on field spectrometer data recorded on 9-track magnetic tape. The quality testing involves the comparison of key housekeeping and data parameters with historic and predetermined tolerance limits. Samples of key parameters are processed during the calibration period and wavelength cal period, and the results are printed out and recorded on an historical file tape.

  11. Pulse Doppler ultrasound as a tool for the diagnosis of chronic testicular dysfunction in stallions

    PubMed Central

    Ortiz-Rodriguez, Jose M.; Anel-Lopez, Luis; Martín-Muñoz, Patricia; Álvarez, Mercedes; Gaitskell-Phillips, Gemma; Anel, Luis; Rodríguez-Medina, Pedro; Peña, Fernando J.

    2017-01-01

    Testicular function is particularly susceptible to vascular insult, resulting in a negative impact on sperm production and quality of the ejaculate. A prompt diagnosis of testicular dysfunction enables implementation of appropriate treatment, hence improving fertility forecasts for stallions. The present research aims to: (1) assess if Doppler ultrasonography is a good tool to diagnose stallions with testicular dysfunction; (2) to study the relationship between Doppler parameters of the testicular artery and those of sperm quality assessed by flow cytometry and (3) to establish cut off values to differentiate fertile stallions from those with pathologies causing testicular dysfunction. A total of 10 stallions (n: 7 healthy stallions and n: 3 sub-fertile stallions) were used in this study. Two ejaculates per stallion were collected and preserved at 5°C in a commercial extender. The semen was evaluated at T0, T24 and T48h by flow cytometry. Integrity and viability of sperm (YoPro®-1/EthD-1), mitochondrial activity (MitoTracker® Deep Red FM) and the DNA fragmentation index (Sperm Chromatin Structure Assay) were assessed. Doppler parameters were measured at three different locations on the testicular artery (Supratesticular artery (SA); Capsular artery (CA) and Intratesticular artery (IA)). The Doppler parameters calculated were: Resistive Index (RI), Pulsatility Index (PI), Peak Systolic Velocity (PSV), End Diastolic Velocity (EDV), Time Average Maximum Velocity (TAMV), Total Arterial Blood Flow (TABF) and TABF rate. The capsular artery was the most reliable location to carry out spectral Doppler assessment, since blood flow parameters of this artery were most closely correlated with sperm quality parameters. Significant differences in all the Doppler parameters studied were observed between fertile and subfertile stallions (p ≤ 0.05). The principal components analysis assay determined that fertile stallions are characterized by high EDV, TAMV, TABF and TABF rate values (high vascular perfusion). In contrast, subfertile stallions tend to present high values of PI and RI (high vascular resistance). The ROC curves revealed that the best Doppler parameters to predict sperm quality in stallions were: Doppler velocities (PSV, EDV and TAMV), the diameter of the capsular artery and TABF parameters (tissue perfusion parameters). Cut off values were established using a Youden´s Index to identify fertile stallions from stallions with testicular dysfunction. Spectral Doppler ultrasound is a good predictive tool for sperm quality since correlations were determined among Doppler parameters and markers of sperm quality. Doppler ultrasonography could be a valuable diagnostic tool for use by clinical practitioners for the diagnosis of stallions with testicular dysfunction and could be a viable alternative to invasive procedures traditionally used for diagnosis of sub-fertility disorders. PMID:28558006

  12. PV cells electrical parameters measurement

    NASA Astrophysics Data System (ADS)

    Cibira, Gabriel

    2017-12-01

    When measuring optical parameters of a photovoltaic silicon cell, precise results bring good electrical parameters estimation, applying well-known physical-mathematical models. Nevertheless, considerable re-combination phenomena might occur in both surface and intrinsic thin layers within novel materials. Moreover, rear contact surface parameters may influence close-area re-combination phenomena, too. Therefore, the only precise electrical measurement approach is to prove assumed cell electrical parameters. Based on theoretical approach with respect to experiments, this paper analyses problems within measurement procedures and equipment used for electrical parameters acquisition within a photovoltaic silicon cell, as a case study. Statistical appraisal quality is contributed.

  13. Stability evaluation of quality parameters for palm oil products at low temperature storage.

    PubMed

    Ramli, Nur Aainaa Syahirah; Mohd Noor, Mohd Azmil; Musa, Hajar; Ghazali, Razmah

    2018-07-01

    Palm oil is one of the major oils and fats produced and traded worldwide. The value of palm oil products is mainly influenced by their quality. According to ISO 17025:2005, accredited laboratories require a quality control procedure with respect to monitoring the validity of tests for determination of quality parameters. This includes the regular use of internal quality control using secondary reference materials. Unfortunately, palm oil reference materials are not currently available. To establish internal quality control samples, the stability of quality parameters needs to be evaluated. In the present study, the stability of quality parameters for palm oil products was examined over 10 months at low temperature storage (6 ± 2 °C). The palm oil products tested included crude palm oil (CPO); refined, bleached and deodorized (RBD) palm oil (RBDPO); RBD palm olein (RBDPOo); and RBD palm stearin (RBDPS). The quality parameters of the oils [i.e. moisture content, free fatty acid content (FFA), iodine value (IV), fatty acids composition (FAC) and slip melting point (SMP)] were determined prior to and throughout the storage period. The moisture, FFA, IV, FAC and SMP for palm oil products changed significantly (P < 0.05), whereas the moisture content for CPO, IV for RBDPO and RBDPOo, stearic acid composition for CPO and linolenic acid composition for CPO, RBDPO, RBDPOo and RBDPS did not (P > 0.05). The stability study indicated that the quality of the palm oil products was stable within the specified limits throughout the storage period at low temperature. The storage conditions preserved the quality of palm oil products throughout the storage period. These findings qualify the use of the palm oil products CPO, RBDPO, RBDPOo and RBDPS as control samples in the validation of test results. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  14. Age-related differences in quality of standing balance using a composite score.

    PubMed

    Pasma, Jantsje H; Bijlsma, Astrid Y; van der Bij, Mark D W; Arendzen, J Hans; Meskers, Carel G M; Maier, Andrea B

    2014-01-01

    Age-related differences in standing balance are not detected by testing the ability to maintain balance. Quality of standing balance might be more sensitive to detect age-related differences. To study age-related differences in quality of standing balance, center of pressure (CoP) movement was evaluated using a wide range of CoP parameters in several standing conditions in healthy young and old participants. In 35 healthy young (18-30 years) and 75 healthy old (70-80 years) participants, CoP movement was assessed in eight standing conditions on a force plate, including side-by-side, one-leg, semi-tandem and tandem stance, both with eyes open and eyes closed. Direction-specific CoP composite scores were calculated from standardized single CoP parameters (mean amplitude, amplitude variability, mean velocity, velocity variability and range) in anterior-posterior (AP) and medial-lateral (ML) direction. Linear regression analysis was used to detect age-related differences in single CoP parameters and composite scores - adjusted for gender, height and weight. Overall, single CoP parameters were higher in old compared to young participants, but no single CoP parameter consistently demonstrated the largest effect size for all standing conditions. Age-related differences were demonstrated for CoP composite scores in AP direction (tandem eyes open; semi-tandem eyes closed; p < 0.001). CoP composite scores in ML direction were consistently higher for all standing conditions in old compared to young participants (p < 0.001). CoP composite scores in ML direction were the most consistent parameters to detect age-related differences in quality of standing balance in healthy participants and might be of clinical value to detect subtle changes in quality of standing balance. © 2014 S. Karger AG, Basel

  15. [The design and experiment of multi-parameter water quality monitoring microsystem based on MOEMS microspectrometer].

    PubMed

    Wei, Kang-Lin; Wen, Zhi-Yu; Guo, Jian; Chen, Song-Bo

    2012-07-01

    Aiming at the monitoring and protecting of water resource environment, a multi-parameter water quality monitoring microsystem based on microspectrometer was put forward in the present paper. The microsystem is mainly composed of MOEMS microspectrometer, flow paths system and embedded measuring & controlling system. It has the functions of self-injecting samples and detection regents, automatic constant temperature, self -stirring, self- cleaning and samples' spectrum detection. The principle prototype machine of the microsystem was developed, and its structure principle was introduced in the paper. Through experiment research, it was proved that the principle prototype machine can rapidly detect quite a few water quality parameters and can meet the demands of on-line water quality monitoring, moreover, the principle prototype machine has strong function expansibility.

  16. Water quality parameters of harbors of Charlotte Amalie, St. Thomas, Virgin Islands: Acquisition of in situ water data, intercorrelation of selected water parameters, and initial correlation of these in situ biological, chemical and physical data with ERTS-1 bulk CCT MSS band 5 data

    NASA Technical Reports Server (NTRS)

    Coulbourn, W. C.; Olsen, D. A. (Principal Investigator)

    1973-01-01

    The author has identified the following significant results. Remote sensing by the ERTS-1 satellite was compared with selected water quality parameters including pH, salinity, conductivity, dissolved oxygen, water depth, water temperature, turbidity, plankton concentration, current variables, chlorophylla, total carotenoids, and species diversity of the benthic community. Strong correlation between turbidity and MSS-sensed radiance was recorded and less strong correlations between the two plankton pigments and radiance. Turbidity and benthic species diversity were highly correlated furnishing an inferential tie between an easily sensed water quality variable and a sensitive indicator of average water quality conditions.

  17. Potable groundwater quality in some villages of Haryana, India: focus on fluoride.

    PubMed

    Bishnoi, Mukul; Arora, Shalu

    2007-04-01

    The fluoride concentration in ground water was determined in ten villages of Rohtak district of Haryana state (India). The fluoride concentration in the underground water of these villages varied from 0.034-2.09 mg/l. Various other water quality parameters, viz., pH, electrical conductivity, total dissolved salts, total hardness, total alkalinity sodium, potassium, calcium, magnesium, carbonate, bicarbonate, chloride and sulfate were also measured. A systematic calculation of correlation coefficients among different physicochemical parameters indicated considerable variations among the analyzed samples with respect to their chemical composition. Majority of the samples do not comply with Indian as well as WHO standards for most of the water quality parameters measured. Overall water quality was found unsatisfactory for drinking purposes. Fluoride content was higher than permissible limit in 50% samples.

  18. Accuracy Estimation and Parameter Advising for Protein Multiple Sequence Alignment

    PubMed Central

    DeBlasio, Dan

    2013-01-01

    Abstract We develop a novel and general approach to estimating the accuracy of multiple sequence alignments without knowledge of a reference alignment, and use our approach to address a new task that we call parameter advising: the problem of choosing values for alignment scoring function parameters from a given set of choices to maximize the accuracy of a computed alignment. For protein alignments, we consider twelve independent features that contribute to a quality alignment. An accuracy estimator is learned that is a polynomial function of these features; its coefficients are determined by minimizing its error with respect to true accuracy using mathematical optimization. Compared to prior approaches for estimating accuracy, our new approach (a) introduces novel feature functions that measure nonlocal properties of an alignment yet are fast to evaluate, (b) considers more general classes of estimators beyond linear combinations of features, and (c) develops new regression formulations for learning an estimator from examples; in addition, for parameter advising, we (d) determine the optimal parameter set of a given cardinality, which specifies the best parameter values from which to choose. Our estimator, which we call Facet (for “feature-based accuracy estimator”), yields a parameter advisor that on the hardest benchmarks provides more than a 27% improvement in accuracy over the best default parameter choice, and for parameter advising significantly outperforms the best prior approaches to assessing alignment quality. PMID:23489379

  19. Qualitative Parameters for Evaluation Procedures of Non-Formal and Informal Learning Achievements

    ERIC Educational Resources Information Center

    Stasiunaitiene, Egle; Kaminskiene, Lina

    2009-01-01

    The article introduces evaluation principles of non-formal and informal learning that determine the quality of evaluation, describes stages of the evaluation procedure, differentiates their qualitative parameters and defines their criteria and indicators. It also brings in the discussion that consideration of qualitative parameters for the…

  20. Water Quality Assessment of Danjiangkou Reservoir and its Tributaries in China

    NASA Astrophysics Data System (ADS)

    Liu, Linghua; Peng, Wenqi; Wu, Leixiang; Liu, Laisheng

    2018-01-01

    Danjiangkou Reservoir is an important water source for the middle route of the South to North Water Diversion Project in China, and water quality of Danjiangkou Reservoir and its tributaries is crucial for the project. The purpose of this study is to evaluate the water quality of Daniiangkou Reservoir and its tributaries based on Canadian Council of Ministers of the Environment Water Quality Index (CCMEWQI). 22 water quality parameters from 25 sampling sites were analyzed to calculate WQI. The results indicate that water quality in Danjiangkou Reservoir area, Hanjiang River and Danjiang River is excellent. And the seriously polluted tributary rivers were Shending River, Jianghe River, Sihe River, Tianhe River, Jianhe River and Jiangjun River. Water quality parameters that cannot meet the standard limit for drinking water source were fecal coliform bacteria, CODcr, CODMn, BOD5, NH3-N, TP, DO, anionic surfactant and petroleum. Fecal coliform bacteria, TP, ammonia nitrogen, CODMn were the most common parameters to fail.

  1. Catchment process affecting drinking water quality, including the significance of rainfall events, using factor analysis and event mean concentrations.

    PubMed

    Cinque, Kathy; Jayasuriya, Niranjali

    2010-12-01

    To ensure the protection of drinking water an understanding of the catchment processes which can affect water quality is important as it enables targeted catchment management actions to be implemented. In this study factor analysis (FA) and comparing event mean concentrations (EMCs) with baseline values were techniques used to asses the relationships between water quality parameters and linking those parameters to processes within an agricultural drinking water catchment. FA found that 55% of the variance in the water quality data could be explained by the first factor, which was dominated by parameters usually associated with erosion. Inclusion of pathogenic indicators in an additional FA showed that Enterococcus and Clostridium perfringens (C. perfringens) were also related to the erosion factor. Analysis of the EMCs found that most parameters were significantly higher during periods of rainfall runoff. This study shows that the most dominant processes in an agricultural catchment are surface runoff and erosion. It also shows that it is these processes which mobilise pathogenic indicators and are therefore most likely to influence the transport of pathogens. Catchment management efforts need to focus on reducing the effect of these processes on water quality.

  2. [Sensitivity analysis of AnnAGNPS model's hydrology and water quality parameters based on the perturbation analysis method].

    PubMed

    Xi, Qing; Li, Zhao-Fu; Luo, Chuan

    2014-05-01

    Sensitivity analysis of hydrology and water quality parameters has a great significance for integrated model's construction and application. Based on AnnAGNPS model's mechanism, terrain, hydrology and meteorology, field management, soil and other four major categories of 31 parameters were selected for the sensitivity analysis in Zhongtian river watershed which is a typical small watershed of hilly region in the Taihu Lake, and then used the perturbation method to evaluate the sensitivity of the parameters to the model's simulation results. The results showed that: in the 11 terrain parameters, LS was sensitive to all the model results, RMN, RS and RVC were generally sensitive and less sensitive to the output of sediment but insensitive to the remaining results. For hydrometeorological parameters, CN was more sensitive to runoff and sediment and relatively sensitive for the rest results. In field management, fertilizer and vegetation parameters, CCC, CRM and RR were less sensitive to sediment and particulate pollutants, the six fertilizer parameters (FR, FD, FID, FOD, FIP, FOP) were particularly sensitive for nitrogen and phosphorus nutrients. For soil parameters, K is quite sensitive to all the results except the runoff, the four parameters of the soil's nitrogen and phosphorus ratio (SONR, SINR, SOPR, SIPR) were less sensitive to the corresponding results. The simulation and verification results of runoff in Zhongtian watershed show a good accuracy with the deviation less than 10% during 2005- 2010. Research results have a direct reference value on AnnAGNPS model's parameter selection and calibration adjustment. The runoff simulation results of the study area also proved that the sensitivity analysis was practicable to the parameter's adjustment and showed the adaptability to the hydrology simulation in the Taihu Lake basin's hilly region and provide reference for the model's promotion in China.

  3. Information system of forest growth and productivity by site quality type and elements of forest

    NASA Astrophysics Data System (ADS)

    Khlyustov, V.

    2012-04-01

    Information system of forest growth and productivity by site quality type and elements of forest V.K. Khlustov Head of the Forestry Department of Russian State Agrarian University named after K.A.Timiryazev doctor of agricultural sciences, professor The efficiency of forest management can be improved substantially by development and introduction of principally new models of forest growth and productivity dynamics based on regionalized site specific parameters. Therefore an innovative information system was developed. It describes the current state and gives a forecast for forest stand parameters: growth, structure, commercial and biological productivity depend on type of site quality. In contrast to existing yield tables, the new system has environmental basis: site quality type. The information system contains set of multivariate statistical models and can work at the level of individual trees or at the stand level. The system provides a graphical visualization, as well as export of the emulation results. The System is able to calculate detailed description of any forest stand based on five initial indicators: site quality type, site index, stocking, composition, and tree age by elements of the forest. The results of the model run are following parameters: average diameter and height, top height, number of trees, basal area, growing stock (total, commercial with distribution by size, firewood and residuals), live biomass (stem, bark, branches, foliage). The system also provides the distribution of mentioned above forest stand parameters by tree diameter classes. To predict the future forest stand dynamics the system require in addition the time slot only. Full set of forest parameters mention above will be provided by the System. The most conservative initial parameters (site quality type and site index) can be kept in the form of geo referenced polygons. In this case the system would need only 3 dynamic initial parameters (stocking, composition and age) to simulate forest parameters and their dynamics. The system can substitute traditional processing of forest inventory field data and provide users with detailed information on the current state of forest and give a prediction. Implementation of the proposed system in combination with high resolution remote sensing is able to increase significantly the quality of forest inventory and at the same time reduce the costs. The system is a contribution to site oriented forest management. The System is registered in the Russian State Register of Computer Programs 12.07.2011, No 2011615418.

  4. Modelling Parameters Characterizing Selected Water Supply Systems in Lower Silesia Province

    NASA Astrophysics Data System (ADS)

    Nowogoński, Ireneusz; Ogiołda, Ewa

    2017-12-01

    The work presents issues of modelling water supply systems in the context of basic parameters characterizing their operation. In addition to typical parameters, such as water pressure and flow rate, assessing the age of the water is important, as a parameter of assessing the quality of the distributed medium. The analysis was based on two facilities, including one with a diverse spectrum of consumers, including residential housing and industry. The carried out simulations indicate the possibility of the occurrence of water quality degradation as a result of excessively long periods of storage in the water supply network. Also important is the influence of the irregularity of water use, especially in the case of supplying various kinds of consumers (in the analysed case - mining companies).

  5. A procedure for testing the quality of LANDSAT atmospheric correction algorithms

    NASA Technical Reports Server (NTRS)

    Dias, L. A. V. (Principal Investigator); Vijaykumar, N. L.; Neto, G. C.

    1982-01-01

    There are two basic methods for testing the quality of an algorithm to minimize atmospheric effects on LANDSAT imagery: (1) test the results a posteriori, using ground truth or control points; (2) use a method based on image data plus estimation of additional ground and/or atmospheric parameters. A procedure based on the second method is described. In order to select the parameters, initially the image contrast is examined for a series of parameter combinations. The contrast improves for better corrections. In addition the correlation coefficient between two subimages, taken at different times, of the same scene is used for parameter's selection. The regions to be correlated should not have changed considerably in time. A few examples using this proposed procedure are presented.

  6. Variability of morphometric parameters of human trabecular tissue from coxo-arthritis and osteoporotic samples.

    PubMed

    Marinozzi, Franco; Marinozzi, Andrea; Bini, Fabiano; Zuppante, Francesca; Pecci, Raffaella; Bedini, Rossella

    2012-01-01

    Morphometric and architectural bone parameters change in diseases such as osteoarthritis and osteoporosis. The mechanical strength of bone is primarily influenced by bone quantity and quality. Bone quality is defined by parameters such as trabecular thickness, trabecular separation, trabecular density and degree of anisotropy that describe the micro-architectural structure of bone. Recently, many studies have validated microtomography as a valuable investigative technique to assess bone morphometry, thanks to micro-CT non-destructive, non-invasive and reliability features, in comparison to traditional techniques such as histology. The aim of this study is the analysis by micro-computed tomography of six specimens, extracted from patients affected by osteoarthritis and osteoporosis, in order to observe the tridimensional structure and calculate several morphometric parameters.

  7. On-Line Water Quality Parameters as Indicators of Distribution System Contamination

    EPA Science Inventory

    At a time when the safety and security of services we have typically taken for granted are under question, a real-time or near real-time method of monitoring changes in water quality parameters could provide a critical line of defense in protecting public health. This study was u...

  8. Variation of protein MWD parameters and their associations with free asparagine concentration and quality characteristics in hard red spring wheat

    USDA-ARS?s Scientific Manuscript database

    This research was performed to determine variation of protein molecular weight distribution (MWD) parameters using size exclusion HPLC and their associations with quality characteristics and free asparagine concentration (FAC) using eleven hard red spring (HRS) wheat genotypes grown at three locatio...

  9. ANNUAL CYCLE OF PERIPHYTON, ZOOPLANKTON, AND WATER QUALITY PARAMETERS ALONG A 5 STATION TRANSECT OF ESCAMBIA BAY, FL

    EPA Science Inventory

    Phytoplankton, zooplankton and water quality parameters were monitored monthly along a 5-station transect in Escambia Bay (Pensacola, FL) from fall 1999 to fall 2000. To provide insight into nutrient processing in Escambia Bay and effects of grazers on phytoplankton community st...

  10. Influence of extrusion-cooking parameters on some quality aspects of precooked pasta-like products.

    PubMed

    Wójtowicz, A; Mościcki, L

    2009-06-01

    The present article aims to evaluate some quality parameters and texture characteristics of precooked wheat pasta-like products. Using the methods for pasta and instant noodles the tested parameters were water absorption, starch gelatinization degree, cooking losses, and hardness. The texture profile was characterized using Zwick apparatus by cutting test with the head speed of 10 mm/min and expressed as hardness and firmness of hydrated products. SEM pictures were used to illustrate the internal structure of dry and cooked pasta-like products. Dough moisture content and process conditions influenced all tested quality parameters of the pasta-like products processed on a modified single screw extrusion-cooker TS-45 with L: D = 16: 1. Good organoleptical quality (notes higher than 4 in a 5-point scale) and firm texture were observed for common wheat flour pasta processed at 30% m.c. Hardness and firmness of hydrated products lowered with a longer hydration time in hot water. The firmest texture and low stickiness was observed for products with a highest starch gelatinization degree.

  11. Developing a quality by design approach to model tablet dissolution testing: an industrial case study.

    PubMed

    Yekpe, Ketsia; Abatzoglou, Nicolas; Bataille, Bernard; Gosselin, Ryan; Sharkawi, Tahmer; Simard, Jean-Sébastien; Cournoyer, Antoine

    2018-07-01

    This study applied the concept of Quality by Design (QbD) to tablet dissolution. Its goal was to propose a quality control strategy to model dissolution testing of solid oral dose products according to International Conference on Harmonization guidelines. The methodology involved the following three steps: (1) a risk analysis to identify the material- and process-related parameters impacting the critical quality attributes of dissolution testing, (2) an experimental design to evaluate the influence of design factors (attributes and parameters selected by risk analysis) on dissolution testing, and (3) an investigation of the relationship between design factors and dissolution profiles. Results show that (a) in the case studied, the two parameters impacting dissolution kinetics are active pharmaceutical ingredient particle size distributions and tablet hardness and (b) these two parameters could be monitored with PAT tools to predict dissolution profiles. Moreover, based on the results obtained, modeling dissolution is possible. The practicality and effectiveness of the QbD approach were demonstrated through this industrial case study. Implementing such an approach systematically in industrial pharmaceutical production would reduce the need for tablet dissolution testing.

  12. Evolution of mammographic image quality in the state of Rio de Janeiro*

    PubMed Central

    Villar, Vanessa Cristina Felippe Lopes; Seta, Marismary Horsth De; de Andrade, Carla Lourenço Tavares; Delamarque, Elizabete Vianna; de Azevedo, Ana Cecília Pedrosa

    2015-01-01

    Objective To evaluate the evolution of mammographic image quality in the state of Rio de Janeiro on the basis of parameters measured and analyzed during health surveillance inspections in the period from 2006 to 2011. Materials and Methods Descriptive study analyzing parameters connected with imaging quality of 52 mammography apparatuses inspected at least twice with a one-year interval. Results Amongst the 16 analyzed parameters, 7 presented more than 70% of conformity, namely: compression paddle pressure intensity (85.1%), films development (72.7%), film response (72.7%), low contrast fine detail (92.2%), tumor mass visualization (76.5%), absence of image artifacts (94.1%), mammography-specific developers availability (88.2%). On the other hand, relevant parameters were below 50% conformity, namely: monthly image quality control testing (28.8%) and high contrast details with respect to microcalcifications visualization (47.1%). Conclusion The analysis revealed critical situations in terms of compliance with the health surveillance standards. Priority should be given to those mammography apparatuses that remained non-compliant at the second inspection performed within the one-year interval. PMID:25987749

  13. Evaluation of the chemical quality traits of soybean seeds, as related to sensory attributes of soymilk.

    PubMed

    Ma, Lei; Li, Bin; Han, Fenxia; Yan, Shurong; Wang, Lianzheng; Sun, Junming

    2015-04-15

    The soybean seed chemical quality traits (including protein content, oil content, fatty acid composition, isoflavone content, and protein subunits), soymilk chemical character (soluble solid), and soymilk sensory attributes were evaluated among 70 genotypes to determine the correlation between seed chemical quality traits and soymilk sensory attributes. Six sensory parameters (i.e., soymilk aroma, smoothness in the mouth, thickness in the mouth, sweetness, colour and appearance, and overall acceptability) and a seven-point hedonic scale for each parameter were developed. Significant positive correlations were observed between overall acceptability and the other five evaluation parameters, suggesting that overall acceptability is an ideal parameter for evaluating soymilk flavour. The soymilk sensory attributes were significantly positively correlated with the characteristics of the glycinin (11S)/beta-conglycinin (7S) protein ratio, soluble solid, and oil content but negatively correlated with glycitein and protein content. Our results indicated that soymilk sensory attributes could be improved by selecting the desirable seed chemical quality traits in practical soybean breeding programs. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  14. Water Quality Management Studies. Postimpoundment Study of R.E. ’Bob’ Woodruff Lake, Alabama River, Alabama.

    DTIC Science & Technology

    1984-08-01

    8 3. Water-quality, sediment, and biological parameters, associated units, EPA STORET codes, container type, 0 preservative and methods used for...Section III.B). Water samples were collected and preserved according to * _ approved EPA (1974) or American Public Health Association (APHA) (1975...procedures. Water-quality parameters tested, associated units, EPA STORET codes, test procedures, and preservation tech- niques used throughout the

  15. Water quality in the Schuylkill River, Pennsylvania: the potential for long-lead forecasts

    NASA Astrophysics Data System (ADS)

    Block, P. J.; Peralez, J.

    2012-12-01

    Prior analysis of pathogen levels in the Schuylkill River has led to a categorical daily forecast of water quality (denoted as red, yellow, or green flag days.) The forecast, available to the public online through the Philadelphia Water Department, is predominantly based on the local precipitation forecast. In this study, we explore the feasibility of extending the forecast to the seasonal scale by associating large-scale climate drivers with local precipitation and water quality parameter levels. This advance information is relevant for recreational activities, ecosystem health, and water treatment (energy, chemicals), as the Schuylkill provides 40% of Philadelphia's water supply. Preliminary results indicate skillful prediction of average summertime water quality parameters and characteristics, including chloride, coliform, turbidity, alkalinity, and others, using season-ahead oceanic and atmospheric variables, predominantly from the North Atlantic. Water quality parameter trends, including historic land use changes along the river, association with climatic variables, and prediction models will be presented.

  16. Temporal and spatial assessment of river surface water quality using multivariate statistical techniques: a study in Can Tho City, a Mekong Delta area, Vietnam.

    PubMed

    Phung, Dung; Huang, Cunrui; Rutherford, Shannon; Dwirahmadi, Febi; Chu, Cordia; Wang, Xiaoming; Nguyen, Minh; Nguyen, Nga Huy; Do, Cuong Manh; Nguyen, Trung Hieu; Dinh, Tuan Anh Diep

    2015-05-01

    The present study is an evaluation of temporal/spatial variations of surface water quality using multivariate statistical techniques, comprising cluster analysis (CA), principal component analysis (PCA), factor analysis (FA) and discriminant analysis (DA). Eleven water quality parameters were monitored at 38 different sites in Can Tho City, a Mekong Delta area of Vietnam from 2008 to 2012. Hierarchical cluster analysis grouped the 38 sampling sites into three clusters, representing mixed urban-rural areas, agricultural areas and industrial zone. FA/PCA resulted in three latent factors for the entire research location, three for cluster 1, four for cluster 2, and four for cluster 3 explaining 60, 60.2, 80.9, and 70% of the total variance in the respective water quality. The varifactors from FA indicated that the parameters responsible for water quality variations are related to erosion from disturbed land or inflow of effluent from sewage plants and industry, discharges from wastewater treatment plants and domestic wastewater, agricultural activities and industrial effluents, and contamination by sewage waste with faecal coliform bacteria through sewer and septic systems. Discriminant analysis (DA) revealed that nephelometric turbidity units (NTU), chemical oxygen demand (COD) and NH₃ are the discriminating parameters in space, affording 67% correct assignation in spatial analysis; pH and NO₂ are the discriminating parameters according to season, assigning approximately 60% of cases correctly. The findings suggest a possible revised sampling strategy that can reduce the number of sampling sites and the indicator parameters responsible for large variations in water quality. This study demonstrates the usefulness of multivariate statistical techniques for evaluation of temporal/spatial variations in water quality assessment and management.

  17. A comprehensive method for GNSS data quality determination to improve ionospheric data analysis.

    PubMed

    Kim, Minchan; Seo, Jiwon; Lee, Jiyun

    2014-08-14

    Global Navigation Satellite Systems (GNSS) are now recognized as cost-effective tools for ionospheric studies by providing the global coverage through worldwide networks of GNSS stations. While GNSS networks continue to expand to improve the observability of the ionosphere, the amount of poor quality GNSS observation data is also increasing and the use of poor-quality GNSS data degrades the accuracy of ionospheric measurements. This paper develops a comprehensive method to determine the quality of GNSS observations for the purpose of ionospheric studies. The algorithms are designed especially to compute key GNSS data quality parameters which affect the quality of ionospheric product. The quality of data collected from the Continuously Operating Reference Stations (CORS) network in the conterminous United States (CONUS) is analyzed. The resulting quality varies widely, depending on each station and the data quality of individual stations persists for an extended time period. When compared to conventional methods, the quality parameters obtained from the proposed method have a stronger correlation with the quality of ionospheric data. The results suggest that a set of data quality parameters when used in combination can effectively select stations with high-quality GNSS data and improve the performance of ionospheric data analysis.

  18. A Comprehensive Method for GNSS Data Quality Determination to Improve Ionospheric Data Analysis

    PubMed Central

    Kim, Minchan; Seo, Jiwon; Lee, Jiyun

    2014-01-01

    Global Navigation Satellite Systems (GNSS) are now recognized as cost-effective tools for ionospheric studies by providing the global coverage through worldwide networks of GNSS stations. While GNSS networks continue to expand to improve the observability of the ionosphere, the amount of poor quality GNSS observation data is also increasing and the use of poor-quality GNSS data degrades the accuracy of ionospheric measurements. This paper develops a comprehensive method to determine the quality of GNSS observations for the purpose of ionospheric studies. The algorithms are designed especially to compute key GNSS data quality parameters which affect the quality of ionospheric product. The quality of data collected from the Continuously Operating Reference Stations (CORS) network in the conterminous United States (CONUS) is analyzed. The resulting quality varies widely, depending on each station and the data quality of individual stations persists for an extended time period. When compared to conventional methods, the quality parameters obtained from the proposed method have a stronger correlation with the quality of ionospheric data. The results suggest that a set of data quality parameters when used in combination can effectively select stations with high-quality GNSS data and improve the performance of ionospheric data analysis. PMID:25196005

  19. The Taguchi Method Application to Improve the Quality of a Sustainable Process

    NASA Astrophysics Data System (ADS)

    Titu, A. M.; Sandu, A. V.; Pop, A. B.; Titu, S.; Ciungu, T. C.

    2018-06-01

    Taguchi’s method has always been a method used to improve the quality of the analyzed processes and products. This research shows an unusual situation, namely the modeling of some parameters, considered technical parameters, in a process that is wanted to be durable by improving the quality process and by ensuring quality using an experimental research method. Modern experimental techniques can be applied in any field and this study reflects the benefits of interacting between the agriculture sustainability principles and the Taguchi’s Method application. The experimental method used in this practical study consists of combining engineering techniques with experimental statistical modeling to achieve rapid improvement of quality costs, in fact seeking optimization at the level of existing processes and the main technical parameters. The paper is actually a purely technical research that promotes a technical experiment using the Taguchi method, considered to be an effective method since it allows for rapid achievement of 70 to 90% of the desired optimization of the technical parameters. The missing 10 to 30 percent can be obtained with one or two complementary experiments, limited to 2 to 4 technical parameters that are considered to be the most influential. Applying the Taguchi’s Method in the technique and not only, allowed the simultaneous study in the same experiment of the influence factors considered to be the most important in different combinations and, at the same time, determining each factor contribution.

  20. Effects of environmental and water quality parameters on the functioning of copepod assemblages in tropical estuaries

    NASA Astrophysics Data System (ADS)

    Araujo, Adriana V.; Dias, Cristina O.; Bonecker, Sérgio L. C.

    2017-07-01

    We examined changes in the functioning of copepod assemblages with increasing pollution in estuaries, using sampling standardization of the salinity range to enable comparisons. Copepod assemblages were analyzed in four southeast Brazilian estuaries with different water quality levels and hydrodynamic characteristics over two years. We obtained mesozooplankton samples together with environmental and water quality parameters in the estuaries, every two months under predetermined salinities ranging from 15 to 25. The values of parameters, except species size, associated with the functioning of the copepod assemblages (biomass, productivity, and turnover rate) did not differ among estuaries. However, in the more polluted estuaries, the biomass and productivity of copepod assemblages of mesozooplankton were negatively correlated with concentration of pollution indicator parameters. Conversely, in the less polluted estuaries some degree of enrichment still seems to increase the system biomass and productivity, as these parameters were inversely related to indicators of improved water quality. The pollution level of estuaries distorted the relationship between temperature and the efficiency of converting energy to organic matter. In the less polluted estuaries, the relationship between turnover rate and temperature was over 70%, while in the most polluted estuaries, this relationship was only approximately 50%. Our results demonstrated that the functioning of assemblages in the estuaries was affected differently by increasing pollution depending on the water quality level of the system. Thus, investigating the functioning of assemblages can be a useful tool for the analysis of estuarine conditions.

  1. The Quality of Methods Reporting in Parasitology Experiments

    PubMed Central

    Flórez-Vargas, Oscar; Bramhall, Michael; Noyes, Harry; Cruickshank, Sheena; Stevens, Robert; Brass, Andy

    2014-01-01

    There is a growing concern both inside and outside the scientific community over the lack of reproducibility of experiments. The depth and detail of reported methods are critical to the reproducibility of findings, but also for making it possible to compare and integrate data from different studies. In this study, we evaluated in detail the methods reporting in a comprehensive set of trypanosomiasis experiments that should enable valid reproduction, integration and comparison of research findings. We evaluated a subset of other parasitic (Leishmania, Toxoplasma, Plasmodium, Trichuris and Schistosoma) and non-parasitic (Mycobacterium) experimental infections in order to compare the quality of method reporting more generally. A systematic review using PubMed (2000–2012) of all publications describing gene expression in cells and animals infected with Trypanosoma spp was undertaken based on PRISMA guidelines; 23 papers were identified and included. We defined a checklist of essential parameters that should be reported and have scored the number of those parameters that are reported for each publication. Bibliometric parameters (impact factor, citations and h-index) were used to look for association between Journal and Author status and the quality of method reporting. Trichuriasis experiments achieved the highest scores and included the only paper to score 100% in all criteria. The mean of scores achieved by Trypanosoma articles through the checklist was 65.5% (range 32–90%). Bibliometric parameters were not correlated with the quality of method reporting (Spearman's rank correlation coefficient <−0.5; p>0.05). Our results indicate that the quality of methods reporting in experimental parasitology is a cause for concern and it has not improved over time, despite there being evidence that most of the assessed parameters do influence the results. We propose that our set of parameters be used as guidelines to improve the quality of the reporting of experimental infection models as a pre-requisite for integrating and comparing sets of data. PMID:25076044

  2. The quality of methods reporting in parasitology experiments.

    PubMed

    Flórez-Vargas, Oscar; Bramhall, Michael; Noyes, Harry; Cruickshank, Sheena; Stevens, Robert; Brass, Andy

    2014-01-01

    There is a growing concern both inside and outside the scientific community over the lack of reproducibility of experiments. The depth and detail of reported methods are critical to the reproducibility of findings, but also for making it possible to compare and integrate data from different studies. In this study, we evaluated in detail the methods reporting in a comprehensive set of trypanosomiasis experiments that should enable valid reproduction, integration and comparison of research findings. We evaluated a subset of other parasitic (Leishmania, Toxoplasma, Plasmodium, Trichuris and Schistosoma) and non-parasitic (Mycobacterium) experimental infections in order to compare the quality of method reporting more generally. A systematic review using PubMed (2000-2012) of all publications describing gene expression in cells and animals infected with Trypanosoma spp was undertaken based on PRISMA guidelines; 23 papers were identified and included. We defined a checklist of essential parameters that should be reported and have scored the number of those parameters that are reported for each publication. Bibliometric parameters (impact factor, citations and h-index) were used to look for association between Journal and Author status and the quality of method reporting. Trichuriasis experiments achieved the highest scores and included the only paper to score 100% in all criteria. The mean of scores achieved by Trypanosoma articles through the checklist was 65.5% (range 32-90%). Bibliometric parameters were not correlated with the quality of method reporting (Spearman's rank correlation coefficient <-0.5; p>0.05). Our results indicate that the quality of methods reporting in experimental parasitology is a cause for concern and it has not improved over time, despite there being evidence that most of the assessed parameters do influence the results. We propose that our set of parameters be used as guidelines to improve the quality of the reporting of experimental infection models as a pre-requisite for integrating and comparing sets of data.

  3. [Value of sepsis single-disease manage system in predicting mortality in patients with sepsis].

    PubMed

    Chen, J; Wang, L H; Ouyang, B; Chen, M Y; Wu, J F; Liu, Y J; Liu, Z M; Guan, X D

    2018-04-03

    Objective: To observe the effect of sepsis single-disease manage system on the improvement of sepsis treatment and the value in predicting mortality in patients with sepsis. Methods: A retrospective study was conducted. Patients with sepsis admitted to the Department of Surgical Intensive Care Unit of Sun Yat-Sen University First Affiliated Hospital from September 22, 2013 to May 5, 2015 were enrolled in this study. Sepsis single-disease manage system (Rui Xin clinical data manage system, China data, China) was used to monitor 25 clinical quality parameters, consisting of timeliness, normalization and outcome parameters. Based on whether these quality parameters could be completed or not, the clinical practice was evaluated by the system. The unachieved quality parameter was defined as suspicious parameters, and these suspicious parameters were used to predict mortality of patients with receiver operating characteristic curve (ROC). Results: A total of 1 220 patients with sepsis were enrolled, included 805 males and 415 females. The mean age was (59±17) years, and acute physiology and chronic health evaluation (APACHE Ⅱ) scores was 19±8. The area under ROC curve of total suspicious numbers for predicting 28-day mortality was 0.70; when the suspicious parameters number was more than 6, the sensitivity was 68.0% and the specificity was 61.0% for predicting 28-day mortality. In addition, the area under ROC curve of outcome suspicious number for predicting 28-day mortality was 0.89; when the suspicious outcome parameters numbers was more than 1, the sensitivity was 88.0% and the specificity was 78.0% for predicting 28-day mortality. Moreover, the area under ROC curve of total suspicious number for predicting 90-day mortality was 0.73; when the total suspicious parameters number was more than 7, the sensitivity was 60.0% and the specificity was 74.0% for predicting 90-day mortality. Finally, the area under ROC curve of outcome suspicious numbers for predicting 90-day mortality was 0.92; when suspicious outcome parameters numbers was more than 1, the sensitivity was 88.0% and the specificity was 81.0% for predicting 90-day mortality. Conclusion: The single center study suggests that this sepsis single-disease manage system could be used to monitor the completion of clinical practice for intensivist in managing sepsis, and the number of quality parameters failed to complete could be used to predict the mortality of the patients.

  4. 40 CFR 60.2945 - Is there a minimum amount of operating parameter monitoring data I must obtain?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... parameter monitoring data I must obtain? 60.2945 Section 60.2945 Protection of Environment ENVIRONMENTAL... Operator Training and Qualification Monitoring § 60.2945 Is there a minimum amount of operating parameter monitoring data I must obtain? (a) Except for monitor malfunctions, associated repairs, and required quality...

  5. 40 CFR 60.2945 - Is there a minimum amount of operating parameter monitoring data I must obtain?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... parameter monitoring data I must obtain? 60.2945 Section 60.2945 Protection of Environment ENVIRONMENTAL... Operator Training and Qualification Monitoring § 60.2945 Is there a minimum amount of operating parameter monitoring data I must obtain? (a) Except for monitor malfunctions, associated repairs, and required quality...

  6. 40 CFR 60.2945 - Is there a minimum amount of operating parameter monitoring data I must obtain?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... parameter monitoring data I must obtain? 60.2945 Section 60.2945 Protection of Environment ENVIRONMENTAL... Operator Training and Qualification Monitoring § 60.2945 Is there a minimum amount of operating parameter monitoring data I must obtain? (a) Except for monitor malfunctions, associated repairs, and required quality...

  7. A large scale GIS geodatabase of soil parameters supporting the modeling of conservation practice alternatives in the United States

    USDA-ARS?s Scientific Manuscript database

    Water quality modeling requires across-scale support of combined digital soil elements and simulation parameters. This paper presents the unprecedented development of a large spatial scale (1:250,000) ArcGIS geodatabase coverage designed as a functional repository of soil-parameters for modeling an...

  8. Effects of build parameters on linear wear loss in plastic part produced by fused deposition modeling

    NASA Astrophysics Data System (ADS)

    Mohamed, Omar Ahmed; Masood, Syed Hasan; Bhowmik, Jahar Lal

    2017-07-01

    Fused Deposition Modeling (FDM) is one of the prominent additive manufacturing technologies for producing polymer products. FDM is a complex additive manufacturing process that can be influenced by many process conditions. The industrial demands required from the FDM process are increasing with higher level product functionality and properties. The functionality and performance of FDM manufactured parts are greatly influenced by the combination of many various FDM process parameters. Designers and researchers always pay attention to study the effects of FDM process parameters on different product functionalities and properties such as mechanical strength, surface quality, dimensional accuracy, build time and material consumption. However, very limited studies have been carried out to investigate and optimize the effect of FDM build parameters on wear performance. This study focuses on the effect of different build parameters on micro-structural and wear performance of FDM specimens using definitive screening design based quadratic model. This would reduce the cost and effort of additive manufacturing engineer to have a systematic approachto make decision among the manufacturing parameters to achieve the desired product quality.

  9. Comprehensive monitoring of drinking well water quality in Seoul metropolitan city, Korea.

    PubMed

    Kim, Ki-Hyun; Susaya, Janice P; Park, Chan Goo; Uhm, Jung-Hoon; Hur, Jin

    2013-08-01

    In this research, the quality of drinking well waters from 14 districts around Seoul metropolitan city, Korea was assessed by measuring a number of parameters with established guideline (e.g., arsenic, fluoride, nitrate nitrogen, benzene, 1,2-dichloroethene, dichloromethane, copper, and lead) and without such criteria (e.g., hardness, chloride ion, sulfate ion, ammonia nitrogen, aluminum, iron, manganese, and zinc). Physical parameters such as evaporation residue (or total dissolved solids) and turbidity were also measured. The importance of each parameter in well waters was examined in terms of the magnitude and exceedance frequency of guideline values established by international (and national) health agencies. The results of this study indicate that among the eight parameters with well-established guidelines (e.g., WHO), arsenic and lead (guideline value of 0.01 mg L(-1) for both) recorded the highest exceedance frequency of 18 and 16 well samples ranging in 0.06-136 and 2-9 mg L(-1), respectively. As such, a number of water quality parameters measured from many well waters in this urban area were in critical levels which require immediate attention for treatment and continuous monitoring.

  10. Improving tablet coating robustness by selecting critical process parameters from retrospective data.

    PubMed

    Galí, A; García-Montoya, E; Ascaso, M; Pérez-Lozano, P; Ticó, J R; Miñarro, M; Suñé-Negre, J M

    2016-09-01

    Although tablet coating processes are widely used in the pharmaceutical industry, they often lack adequate robustness. Up-scaling can be challenging as minor changes in parameters can lead to varying quality results. To select critical process parameters (CPP) using retrospective data of a commercial product and to establish a design of experiments (DoE) that would improve the robustness of the coating process. A retrospective analysis of data from 36 commercial batches. Batches were selected based on the quality results generated during batch release, some of which revealed quality deviations concerning the appearance of the coated tablets. The product is already marketed and belongs to the portfolio of a multinational pharmaceutical company. The Statgraphics 5.1 software was used for data processing to determine critical process parameters in order to propose new working ranges. This study confirms that it is possible to determine the critical process parameters and create design spaces based on retrospective data of commercial batches. This type of analysis is thus converted into a tool to optimize the robustness of existing processes. Our results show that a design space can be established with minimum investment in experiments, since current commercial batch data are processed statistically.

  11. Proton-pump inhibitor use does not affect semen quality in subfertile men.

    PubMed

    Keihani, Sorena; Craig, James R; Zhang, Chong; Presson, Angela P; Myers, Jeremy B; Brant, William O; Aston, Kenneth I; Emery, Benjamin R; Jenkins, Timothy G; Carrell, Douglas T; Hotaling, James M

    2018-01-01

    Proton-pump inhibitors (PPIs) are among the most widely used drugs worldwide. PPI use has recently been linked to adverse changes in semen quality in healthy men; however, the effects of PPI use on semen parameters remain largely unknown specifically in cases with male factor infertility. We examined whether PPI use was associated with detrimental effects on semen parameters in a large population of subfertile men. We retrospectively reviewed data from 12 257 subfertile men who had visited our fertility clinic from 2003 to 2013. Patients who reported using any PPIs for >3 months before semen sample collection were included; 7698 subfertile men taking no medication served as controls. Data were gathered on patient age, medication use, and conventional semen parameters; patients taking any known spermatotoxic medication were excluded. Linear mixed-effect regression models were used to test the effect of PPI use on semen parameters adjusting for age. A total of 248 patients (258 samples) used PPIs for at least 3 months before semen collection. In regression models, PPI use (either as the only medication or when used in combination with other nonspermatotoxic medications) was not associated with statistically significant changes in semen parameters. To our knowledge, this is the largest study to compare PPI use with semen parameters in subfertile men. Using PPIs was not associated with detrimental effects on semen quality in this retrospective study.

  12. Impact of freezing and thawing on the quality of meat: review.

    PubMed

    Leygonie, Coleen; Britz, Trevor J; Hoffman, Louwrens C

    2012-06-01

    This comprehensive review describes the effects of freezing and thawing on the physical quality parameters of meat. The formation of ice crystals during freezing damages the ultrastructure and concentrates the solutes in the meat which, in turn, leads to alterations in the biochemical reactions that occur at the cellular level and influence the physical quality parameters of the meat. The quality parameters that were evaluated are moisture loss, protein denaturation, lipid and protein oxidation, colour, pH, shear force and microbial spoilage. Additionally mechanisms employed to mitigate the effects of freezing and thawing were also reviewed. These include the use of novel methods of freezing and thawing, ante and post mortem antifreeze protein inclusion and vitamin E supplementation, brine injection and modified atmospheric packaging. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Assessment of chapatti quality of wheat varieties based on physicochemical, rheological and sensory traits.

    PubMed

    Kundu, Manju; Khatkar, Bhupendar Singh; Gulia, Neelam

    2017-07-01

    Fifty wheat varieties were assessed for chapatti quality using grain characteristics, dough rheological properties and pasting characteristics. Results revealed that 88% of wheat varieties studied were medium-hard to hard based on kernel texture. Water absorption and damaged starch were found to be important parameters for chapatti quality as both parameters had significant positive effect on the pliability and puffing height of chapatti. Protein content and gluten strength parameters like SDS sedimentation volume, dough stability and gluten index were found to have a negative impact on chapatti quality. Based on chapatti quality assessment the wheat varieties were classified into four distinct clusters viz. good, acceptable, fair and poor for chapatti making. It was elucidated that 46% of the varieties studied were good to acceptable for chapatti making, while 54% resulted in fair or poor chapatti quality thereby clearly indicating the need to establish and substantiate the development of product-specific varieties. Copyright © 2016. Published by Elsevier Ltd.

  14. Spatial distribution and temporal variation of chemical properties of drainage watercourses in rural and peri-urban areas of Novi Sad (Serbia)-a case study.

    PubMed

    Savic, Radovan; Ondrasek, Gabrijel; Blagojevic, Bosko; Bubalo Kovacic, Marina; Zemunac, Rados

    2017-12-29

    Waters are among to the most vulnerable environmental resources exposed to the impact of various point and non-point pollutants from rural/urban activities. Systematic and long-term monitoring of hydro-resources is therefore of crucial importance for sustainable water management, although such practice is lacking across many (agro-)hydro-ecosystems. In the presented study, for the first time, the spatial distribution (covering almost 9000 ha) and temporal variation (2006-2013) in certain quality parameters was characterized in drainage watercourses Tatarnica and Subic, whose catchment is rural and suburban areas close to the city of Novi Sad, Republic of Serbia. Based on majority of observed parameters, both watercourses belonged to I and II water quality classes, with occasional presence of certain parameters (e.g., suspended solids, total phosphorus; ammonium) at extreme values exacerbating both watercourses to classes IV and V. The value of the synthetic pollution index (i.e., a combined effect of all considered parameters) showed a higher degree of water pollution in watercourse Subic (on average 2.00) than Tatarnica (on average 0.72). Also, cluster analysis for watercourse Tatarnica detected two groups of parameters (mostly related to nutrients and organic matter), indicating more complex impacts on water quality during the observed period, in which elucidation thus established water quality monitoring program would be of great importance.

  15. Critical levels as applied to ozone for North American forests

    Treesearch

    Robert C. Musselman

    2006-01-01

    The United States and Canada have used concentration-based parameters for air quality standards for ozone effects on forests in North America. The European critical levels method for air quality standards uses an exposure-based parameter, a cumulative ozone concentration index with a threshold cutoff value. The critical levels method has not been used in North America...

  16. Microwave moisture sensing of seedcotton: Part 1: Seedcotton microwave material properties

    USDA-ARS?s Scientific Manuscript database

    Moisture content at harvest is a key parameter that impacts quality and how well the cotton crop can be stored without degrading before processing. It is also a key parameter of interest for harvest time field trials as it can directly influence the quality of the harvested crop as well as alter the...

  17. Water quality parameter measurement using spectral signatures

    NASA Technical Reports Server (NTRS)

    White, P. E.

    1973-01-01

    Regression analysis is applied to the problem of measuring water quality parameters from remote sensing spectral signature data. The equations necessary to perform regression analysis are presented and methods of testing the strength and reliability of a regression are described. An efficient algorithm for selecting an optimal subset of the independent variables available for a regression is also presented.

  18. A Case Study Showing Parameters Affecting the Quality of Education: Faculty Perspective

    ERIC Educational Resources Information Center

    Kumari, Neeraj

    2014-01-01

    The study aims to examine the faculty members' perspective (age Wise, Gender Wise and Work Experience wise) of parameters affecting the quality of education in an affiliated Undergraduate Engineering Institution in Haryana. It is a descriptive type of research. The data has been collected with the help of 'Questionnaire Based Survey'. The sample…

  19. Carcass parameters and meat quality in meat-goat kids finished on chicory, birdsfoot trefoil, or red clover pastures

    USDA-ARS?s Scientific Manuscript database

    This study was conducted in 2009-2010 to assess carcass parameters and chevon (goat meat) quality when meat-goat kids (n = 72) were finished on pastures of red clover (Trifolium pratense L.; RCL), birdsfoot trefoil (Lotus corniculatus L.; BFT), or chicory (Cichorium intybus L.; CHIC). Final body we...

  20. Microwave moisture sensing of seedcotton: Part 1: Seedcotton microwave material properties

    USDA-ARS?s Scientific Manuscript database

    Moisture content at harvest is a key parameter that impacts quality and how well the cotton crop can be stored without degrading before processing. It is also a key parameter of interest for harvest time field trials as it can directly influence the quality of the harvested crop as well as skew the...

  1. Static Magnetic Field Therapy: A Critical Review of Treatment Parameters

    PubMed Central

    Wahbeh, Helané; Harling, Noelle; Connelly, Erin; Schiffke, Heather C.; Forsten, Cora; Gregory, William L.; Markov, Marko S.; Souder, James J.; Elmer, Patricia; King, Valerie

    2009-01-01

    Static magnetic field (SMF) therapy, applied via a permanent magnet attached to the skin, is used by people worldwide for self-care. Despite a lack of established SMF dosage and treatment regimens, multiple studies are conducted to evaluate SMF therapy effectiveness. Our objectives in conducting this review are to:(i) summarize SMF research conducted in humans; (ii) critically evaluate reporting quality of SMF dosages and treatment parameters and (iii) propose a set of criteria for reporting SMF treatment parameters in future clinical trials. We searched 27 electronic databases and reference lists. Only English language human studies were included. Excluded were studies of electromagnetic fields, transcranial magnetic stimulation, magnets placed on acupuncture points, animal studies, abstracts, posters and editorials. Data were extracted on clinical indication, study design and 10 essential SMF parameters. Three reviewers assessed quality of reporting and calculated a quality assessment score for each of the 10 treatment parameters. Fifty-six studies were reviewed, 42 conducted in patient populations and 14 in healthy volunteers. The SMF treatment parameters most often and most completely described were site of application, magnet support device and frequency and duration of application. Least often and least completely described were characteristics of the SMF: magnet dimensions, measured field strength and estimated distance of the magnet from the target tissue. Thirty-four (61%) of studies failed to provide enough detail about SMF dosage to permit protocol replication by other investigators. Our findings highlight the need to optimize SMF dosing parameters for individual clinical conditions before proceeding to a full-scale clinical trial. PMID:18955243

  2. Polishing parameter optimization for end-surface of chalcogenide glass fiber connector

    NASA Astrophysics Data System (ADS)

    Guo, Fangxia; Dai, Shixun; Tang, Junzhou; Wang, Xunsi; Li, Xing; Xu, Yinsheng; Wu, Yuehao; Liu, Zijun

    2017-11-01

    We have investigated the optimization parameters for polishing end-surface of chalcogenide glass fiber connector in the paper. Six SiC abrasive particles of different sizes were used to polish the fiber in order of size from large to small. We analyzed the effects of polishing parameters such as particle sizes, grinding speeds and polishing durations on the quality of the fiber end surface and determined the optimized polishing parameters. We found that, high-quality fiber end surface can be achieved using only three different SiC abrasives. The surface roughness of the final ChG fiber end surface is about 48 nm without any scratches, spots and cracks. Such polishing processes could reduce the average insertion loss of the connector to about 3.4 dB.

  3. A tuned mesh-generation strategy for image representation based on data-dependent triangulation.

    PubMed

    Li, Ping; Adams, Michael D

    2013-05-01

    A mesh-generation framework for image representation based on data-dependent triangulation is proposed. The proposed framework is a modified version of the frameworks of Rippa and Garland and Heckbert that facilitates the development of more effective mesh-generation methods. As the proposed framework has several free parameters, the effects of different choices of these parameters on mesh quality are studied, leading to the recommendation of a particular set of choices for these parameters. A mesh-generation method is then introduced that employs the proposed framework with these best parameter choices. This method is demonstrated to produce meshes of higher quality (both in terms of squared error and subjectively) than those generated by several competing approaches, at a relatively modest computational and memory cost.

  4. Optimization of hydraulic turbine governor parameters based on WPA

    NASA Astrophysics Data System (ADS)

    Gao, Chunyang; Yu, Xiangyang; Zhu, Yong; Feng, Baohao

    2018-01-01

    The parameters of hydraulic turbine governor directly affect the dynamic characteristics of the hydraulic unit, thus affecting the regulation capacity and the power quality of power grid. The governor of conventional hydropower unit is mainly PID governor with three adjustable parameters, which are difficult to set up. In order to optimize the hydraulic turbine governor, this paper proposes wolf pack algorithm (WPA) for intelligent tuning since the good global optimization capability of WPA. Compared with the traditional optimization method and PSO algorithm, the results show that the PID controller designed by WPA achieves a dynamic quality of hydraulic system and inhibits overshoot.

  5. Test and study on mirror quality of ultra-precision diamond turning

    NASA Astrophysics Data System (ADS)

    Chang, Yanyan; Sun, Tao; Li, Zengqiang; Wu, Baosen

    2014-09-01

    Using the diamond turning lathe and mono crystalline diamond tool, the aluminum alloy of 2A12 was cut under different cutting parameters including cutting speed, feed rate and depth of cut and the mirror surfaces were made. The surface roughness, micro hardness and residual stress of the mirror surface were tested by the surface profiler, the universal hardness tester and X-stress Robot. The influences of the cutting parameters on the mirror quality were studied. The research results have theoretical and practical significance to the selection of the optimal cutting parameters in ultraprecision diamond turning.

  6. Influence of tool geometry and processing parameters on welding defects and mechanical properties for friction stir welding of 6061 Aluminium alloy

    NASA Astrophysics Data System (ADS)

    Daneji, A.; Ali, M.; Pervaiz, S.

    2018-04-01

    Friction stir welding (FSW) is a form of solid state welding process for joining metals, alloys, and selective composites. Over the years, FSW development has provided an improved way of producing welding joints, and consequently got accepted in numerous industries such as aerospace, automotive, rail and marine etc. In FSW, the base metal properties control the material’s plastic flow under the influence of a rotating tool whereas, the process and tool parameters play a vital role in the quality of weld. In the current investigation, an array of square butt joints of 6061 Aluminum alloy was to be welded under varying FSW process and tool geometry related parameters, after which the resulting weld was evaluated for the corresponding mechanical properties and welding defects. The study incorporates FSW process and tool parameters such as welding speed, pin height and pin thread pitch as input parameters. However, the weld quality related defects and mechanical properties were treated as output parameters. The experimentation paves way to investigate the correlation between the inputs and the outputs. The correlation between inputs and outputs were used as tool to predict the optimized FSW process and tool parameters for a desired weld output of the base metals under investigation. The study also provides reflection on the effect of said parameters on a welding defect such as wormhole.

  7. Differential recovery of water quality parameters eight years after severe wildfire and salvage logging in Alberta's southern Rocky Mountains

    NASA Astrophysics Data System (ADS)

    Silins, U.; Bladon, K. D.; Stone, M.; Emelko, M. B.; Collins, A.; Boon, S.; Williams, C.; Wagner, M. J.; Martens, A. M.; Anderson, A.

    2012-12-01

    Broad regions of western North America rely on water supplies that originate from forested regions of the Rocky Mountain cordillera where landuse pressures, and stresses including changing natural disturbance regimes associated with shifting climates has been impacting critical source water supplies from this region. Increases in magnitude and severity of wildfires along with impacts on downstream water supplies has been observed along the length of the North American Rocky Mountain chain, however, the longevity of these impacts (including impacts to important water quality parameters) remain highly uncertain because processes regulating recovery from such disturbances can span a range of timescales from a few years to decades depending on both the hydro-climatic regime, and which water quality parameters are important. Studies document such long-term changes are few. The Southern Rockies Watershed Project (SRWP) was established to document the magnitude and recovery from the severe 2003 Lost Creek wildfire in the Crowsnest Pass region of southwest Alberta, Canada. Hydrology, water quality (physical & chemical) have been studies in 9 instrumented catchments (4-14 km2) encompassing burned, burned and salvage logged, prescribed burned, and unburned (reference) conditions since late winter 2004. While most important water quality parameters were strongly elevated in burned and burned-salvage logged catchments after the fire, strongly differential rates of recovery were observed for contaminant concentration, export, and yield across a range of water quality parameters (2004-2011). For example, while various nitrogen (N) species (total nitrogen, dissolved nitrogen, NO3-, NH4+) showed 2-7 fold increases in concentration the first 1-2 years after the wildfire, N recovered back to baseline concentrations 4-5 years after the wildfire. In contrast, eight full years after the wildfire (2011), no recovery of sediment or phosphorus (P) production (soluble reactive, total dissolved, particulate, and total P) has been evident. Incremental impacts of management intervention by salvage logging over wildfire alone were observed for most water quality parameters. Sedimentary geology, glacial history of this region, along with predominance of fine fluvial sediments are likely implicated in both the strong sediment-P coupling and longevity of wildfire impacts observed in this region.

  8. Prediction of Water Quality Parameters Using Statistical Methods: A Case Study in a Specially Protected Area, Ankara, Turkey

    NASA Astrophysics Data System (ADS)

    Alp, E.; Yücel, Ö.; Özcan, Z.

    2014-12-01

    Turkey has been making many legal arrangements for sustainable water management during the harmonization process with the European Union. In order to make cost effective and efficient decisions, monitoring network in Turkey has been expanding. However, due to time and budget constraints, desired number of monitoring campaigns can not be carried. Hence, in this study, independent parameters that can be measured easily and quickly are used to estimate water quality parameters in Lake Mogan and Eymir using linear regression. Nonpoint sources are one of the major pollutant components in Eymir and Mogan lakes. In this paper, a correlation between easily measurable parameters, DO, temperature, electrical conductivity, pH, precipitation and dependent variables, TN, TP, COD, Chl-a, TSS, Total Coliform is investigated. Simple regression analysis is performed for each season in Eymir and Mogan lakes by using SPSS Statistical program using the water quality data collected between 2006-2012. Regression analysis demonstrated significant linear relationship between measured and simulated concentrations for TN (R2=0.86), TP (R2=0.85), TSS (R2=0.91), Chl-a (R2=0.94), COD (R2=0.99), T. Coliform (R2=0.97) which are the best results in each season for Eymir and Mogan Lakes. The overall results of this study shows that by using easily measurable parameters even in ungauged situation the water quality of lakes can be predicted. Moreover, the outputs obtained from the regression equations can be used as an input for water quality models such as phosphorus budget model which is used to calculate the required reduction in the external phosphorus load to Lake Mogan to meet the water quality standards.

  9. Relationship between the properties of raw and cooked spaghetti - new indices for pasta quality evaluation

    NASA Astrophysics Data System (ADS)

    Biernacka, Beata; Dziki, Dariusz; Różyło, Renata; Wójcik, Monika; Miś, Antoni; Romankiewicz, Daria; Krzysiak, Zbigniew

    2018-04-01

    The quality of pasta can be evaluated by measuring the characteristics which encompass the most important quality parameters, such as colour, cooking properties and texture. The aim of the study was to suggest new indices which can be used to evaluate the quality of pasta. For the tests, 15 samples of spaghetti (produced from either semolina or common wheat flour) were used. The bending test was performed for the determination of the strength properties of raw pasta, while the pasta colour parameters were evaluated via the Commission Internationale de l'Eclairage system. The pasta cooking test included the evaluation of optimum cooking time, weight increase index and cooking loss. The samples of cooked spaghetti were cut, and the parameters describing pasta texture were determined. Statistical analysis showed significant correlations (α = 0.05) between colour parameters (lightness and redness) and pasta ash content (R = -0.90 and 0.84, respectively). The mechanical properties of raw pasta correlated positively with pasta density. The strongest correlation was found between pasta density and flexural strength. The destruction force for raw spaghetti during the bending test correlated significantly and positively with the cutting force of the cooked pasta. The obtained correlations can be helpful in pasta quality evaluation.

  10. Impact of fowlpox-vectored Mycoplasma gallisepticum vaccine Vectormune FP MG on layer hen egg production and egg quality parameters.

    PubMed

    Leigh, S A; Branton, S L; Evans, J D; Collier, S D

    2013-12-01

    This study was conducted to determine the impact of vaccination with Vectormune FP MG on egg production and egg quality characteristics of Single Comb White Leghorn hens. Due to questions of the efficacy of this vaccine in preventing Mycoplasma gallisepticum-mediated pathology, the ability of this vaccine to protect against postproduction-peak egg losses associated with F-strain M. gallisepticum (FMG) vaccination was also investigated. Vaccination with Vectormune FP MG did not result in any significant change in egg production or egg quality parameters compared with control (unvaccinated) hens. Subsequent revaccination with FMG at 45 wk of age (woa) yielded no impact on egg production or egg quality parameters of Vectormune FP MG vaccinated hens, unlike prior results for postproduction-peak vaccination of M. gallisepticum-clean hens with FMG, which exhibited a drop in egg production of approximately 6%. No difference in egg size distribution was observed for any of the treatment groups before or after FMG revaccination. These results suggest that hens can be safely vaccinated with Vectormune FP MG as pullets and can be revaccinated with a live M. gallisepticum vaccine such as FMG at a later date with no deleterious effects on egg production or egg or eggshell quality parameters.

  11. Effect of Friction Stir Process Parameters on the Mechanical and Thermal Behavior of 5754-H111 Aluminum Plates.

    PubMed

    Serio, Livia Maria; Palumbo, Davide; De Filippis, Luigi Alberto Ciro; Galietti, Umberto; Ludovico, Antonio Domenico

    2016-02-23

    A study of the Friction Stir Welding (FSW) process was carried out in order to evaluate the influence of process parameters on the mechanical properties of aluminum plates (AA5754-H111). The process was monitored during each test by means of infrared cameras in order to correlate temperature information with eventual changes of the mechanical properties of joints. In particular, two process parameters were considered for tests: the welding tool rotation speed and the welding tool traverse speed. The quality of joints was evaluated by means of destructive and non-destructive tests. In this regard, the presence of defects and the ultimate tensile strength (UTS) were investigated for each combination of the process parameters. A statistical analysis was carried out to assess the correlation between the thermal behavior of joints and the process parameters, also proving the capability of Infrared Thermography for on-line monitoring of the quality of joints.

  12. Effect of Friction Stir Process Parameters on the Mechanical and Thermal Behavior of 5754-H111 Aluminum Plates

    PubMed Central

    Serio, Livia Maria; Palumbo, Davide; De Filippis, Luigi Alberto Ciro; Galietti, Umberto; Ludovico, Antonio Domenico

    2016-01-01

    A study of the Friction Stir Welding (FSW) process was carried out in order to evaluate the influence of process parameters on the mechanical properties of aluminum plates (AA5754-H111). The process was monitored during each test by means of infrared cameras in order to correlate temperature information with eventual changes of the mechanical properties of joints. In particular, two process parameters were considered for tests: the welding tool rotation speed and the welding tool traverse speed. The quality of joints was evaluated by means of destructive and non-destructive tests. In this regard, the presence of defects and the ultimate tensile strength (UTS) were investigated for each combination of the process parameters. A statistical analysis was carried out to assess the correlation between the thermal behavior of joints and the process parameters, also proving the capability of Infrared Thermography for on-line monitoring of the quality of joints. PMID:28773246

  13. Uncertainty in BMP evaluation and optimization for watershed management

    NASA Astrophysics Data System (ADS)

    Chaubey, I.; Cibin, R.; Sudheer, K.; Her, Y.

    2012-12-01

    Use of computer simulation models have increased substantially to make watershed management decisions and to develop strategies for water quality improvements. These models are often used to evaluate potential benefits of various best management practices (BMPs) for reducing losses of pollutants from sources areas into receiving waterbodies. Similarly, use of simulation models in optimizing selection and placement of best management practices under single (maximization of crop production or minimization of pollutant transport) and multiple objective functions has increased recently. One of the limitations of the currently available assessment and optimization approaches is that the BMP strategies are considered deterministic. Uncertainties in input data (e.g. precipitation, streamflow, sediment, nutrient and pesticide losses measured, land use) and model parameters may result in considerable uncertainty in watershed response under various BMP options. We have developed and evaluated options to include uncertainty in BMP evaluation and optimization for watershed management. We have also applied these methods to evaluate uncertainty in ecosystem services from mixed land use watersheds. In this presentation, we will discuss methods to to quantify uncertainties in BMP assessment and optimization solutions due to uncertainties in model inputs and parameters. We have used a watershed model (Soil and Water Assessment Tool or SWAT) to simulate the hydrology and water quality in mixed land use watershed located in Midwest USA. The SWAT model was also used to represent various BMPs in the watershed needed to improve water quality. SWAT model parameters, land use change parameters, and climate change parameters were considered uncertain. It was observed that model parameters, land use and climate changes resulted in considerable uncertainties in BMP performance in reducing P, N, and sediment loads. In addition, climate change scenarios also affected uncertainties in SWAT simulated crop yields. Considerable uncertainties in the net cost and the water quality improvements resulted due to uncertainties in land use, climate change, and model parameter values.

  14. Evaluation of the Ecochemical Status of the Danube in Serbia in Terms of Water Quality Parameters

    PubMed Central

    Takić, Ljiljana; Mladenović-Ranisavljević, Ivana; Vuković, Milovan; Mladenović, Ilija

    2012-01-01

    The Danube is an international river passing partly through Serbia. The protection of the environment and sustainable use of water resources is a primary task that implies constant monitoring of the quality status and evaluation of ecochemical status of the water in the Danube basin. The investigation includes calculation of all-inclusive water quality by the Serbian water quality index (SWQI) method and an evaluation of eco-chemical status of the Danube water in terms of water quality parameters from the entry to the exit point along its course through Serbia in the year of 2009. The results show that the overall quality of the Danube water on the territory of Serbia corresponds to the descriptive indicator of “very good” water. According to the Council Directive75/440/EEC, the evaluation of the ecostatus, with slight deviation of individual parameters at Pančevo, corresponds to A1 category of the surface water quality intended for the abstraction of drinking water supplies in member states. PMID:22645471

  15. Changes of some functional speech disorders after surgical correction of skeletal anterior open bite.

    PubMed

    Knez Ambrožič, Mojca; Hočevar Boltežar, Irena; Ihan Hren, Nataša

    2015-09-01

    Skeletal anterior open bite (AOB) or apertognathism is characterized by the absence of contact of the anterior teeth and affects articulation parameters, chewing, biting and voice quality. The treatment of AOB consists of orthognatic surgical procedures. The aim of this study was to evaluate the effects of treatment on voice quality, articulation and nasality in speech with respect to skeletal changes. The study was prospective; 15 patients with AOB were evaluated before and after surgery. Lateral cephalometric x-ray parameters (facial angle, interincisal distance, Wits appraisal) were measured to determine skeletal changes. Before surgery, nine patients still had articulation disorders despite speech therapy during childhood. The voice quality parameters were determined by acoustic analysis of the vowel sound /a/ (fundamental frequency-F0, jitter, shimmer). Spectral analysis of vowels /a/, /e/, /i/, /o/, /u/ was carried out by determining the mean frequency of the first (F1) and second (F2) formants. Nasality in speech was expressed as the ratio between the nasal and the oral sound energies during speech samples. After surgery, normalizations of facial skeletal parameters were observed in all patients, but no statistically significant changes in articulation and voice quality parameters occurred despite subjective observations of easier articulation. Any deterioration in velopharyngeal insufficiency was absent in all of the patients. In conclusion, the surgical treatment of skeletal AOB does not lead to deterioration in voice, resonance and articulation qualities. Despite surgical correction of the unfavourable skeletal situation of the speech apparatus, the pre-existing articulation disorder cannot improve without professional intervention.

  16. [Evaluation of social demographic aspect of life quality of coal extraction workers in Kouzbass enterprises].

    PubMed

    Ivoĭlov, V M; Semenikhin, V A; Odintseva, O V; Shternis, T A

    2014-01-01

    For assessing influence of social factors on life quality of workers in coal extraction enterpirses of Kemerovo region, the authors used questionnaire SF-36. Life quality parameters of workers engaged into coal extraction in Kemerovo region appeared to lower with age from 20 to 64 years. Life quality parameters on scales of pain, physical functioning and general health are invertedly correlated with age and length of service in hazardous work conditions for coal extraction workers. Life quality of the miners is influenced by the following factors: marital status, educational level and income level of the workers.

  17. Parameter Trending, Geolocation Quality Control and the Procedures to Support Preparation of Next Versions of the TRMM Reprocessing Algorithm

    NASA Technical Reports Server (NTRS)

    Stocker, Erich Franz

    2004-01-01

    TRMM has been an imminently successful mission from an engineering standpoint but even more from a science standpoint. An important part of this science success has been the careful quality control of the TRMM standard products. This paper will present the quality monitoring efforts that the TRMM Science Data and Information System (TSDIS) conducts on a routine basis. The paper will detail parameter trending, geolocation quality control and the procedures to support the preparation of next versions of the algorithm used for reprocessing.

  18. Spatial variability and long-term analysis of groundwater quality of Faisalabad industrial zone

    NASA Astrophysics Data System (ADS)

    Nasir, Muhammad Salman; Nasir, Abdul; Rashid, Haroon; Shah, Syed Hamid Hussain

    2017-10-01

    Water is the basic necessity of life and is essential for healthy society. In this study, groundwater quality analysis was carried out for the industrial zone of Faisalabad city. Sixty samples of groundwater were collected from the study area. The quality maps of deliberately analyzed results were prepared in GIS. The collected samples were analyzed for chemical parameters and heavy metals, such as total hardness, alkalinity, cadmium, arsenic, nickel, lead, and fluoride, and then, the results were compared with the WHO guidelines. The values of these results were represented by a mapping of quality parameters using the ArcView GIS v9.3, and IDW was used for raster interpolation. The long-term analysis of these parameters has been carried out using the `R Statistical' software. It was concluded that water is partially not fit for drinking, and direct use of this groundwater may cause health issues.

  19. Analyzing the quality robustness of chemotherapy plans with respect to model uncertainties.

    PubMed

    Hoffmann, Anna; Scherrer, Alexander; Küfer, Karl-Heinz

    2015-01-01

    Mathematical models of chemotherapy planning problems contain various biomedical parameters, whose values are difficult to quantify and thus subject to some uncertainty. This uncertainty propagates into the therapy plans computed on these models, which poses the question of robustness to the expected therapy quality. This work introduces a combined approach for analyzing the quality robustness of plans in terms of dosing levels with respect to model uncertainties in chemotherapy planning. It uses concepts from multi-criteria decision making for studying parameters related to the balancing between the different therapy goals, and concepts from sensitivity analysis for the examination of parameters describing the underlying biomedical processes and their interplay. This approach allows for a profound assessment of a therapy plan, how stable its quality is with respect to parametric changes in the used mathematical model. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Investigating the CO 2 laser cutting parameters of MDF wood composite material

    NASA Astrophysics Data System (ADS)

    Eltawahni, H. A.; Olabi, A. G.; Benyounis, K. Y.

    2011-04-01

    Laser cutting of medium density fibreboard (MDF) is a complicated process and the selection of the process parameters combinations is essential to get the highest quality cut section. This paper presents a means for selecting the process parameters for laser cutting of MDF based on the design of experiments (DOE) approach. A CO 2 laser was used to cut three thicknesses, 4, 6 and 9 mm, of MDF panels. The process factors investigated are: laser power, cutting speed, air pressure and focal point position. In this work, cutting quality was evaluated by measuring the upper kerf width, the lower kerf width, the ratio between the upper kerf width to the lower kerf width, the cut section roughness and the operating cost. The effect of each factor on the quality measures was determined. The optimal cutting combinations were presented in favours of high quality process output and in favours of low cutting cost.

  1. Sensoring fusion data from the optic and acoustic emissions of electric arcs in the GMAW-S process for welding quality assessment.

    PubMed

    Alfaro, Sadek Crisóstomo Absi; Cayo, Eber Huanca

    2012-01-01

    The present study shows the relationship between welding quality and optical-acoustic emissions from electric arcs, during welding runs, in the GMAW-S process. Bead on plate welding tests was carried out with pre-set parameters chosen from manufacturing standards. During the welding runs interferences were induced on the welding path using paint, grease or gas faults. In each welding run arc voltage, welding current, infrared and acoustic emission values were acquired and parameters such as arc power, acoustic peaks rate and infrared radiation rate computed. Data fusion algorithms were developed by assessing known welding quality parameters from arc emissions. These algorithms have showed better responses when they are based on more than just one sensor. Finally, it was concluded that there is a close relation between arc emissions and quality in welding and it can be measured from arc emissions sensing and data fusion algorithms.

  2. Modeling of process of forming quality parameters for surfaces of parts by diamond burnishing taking into account technological heredity

    NASA Astrophysics Data System (ADS)

    Nagorkin, M. N.; Fyodorov, V. P.; Kovalyova, E. V.

    2018-03-01

    The paper presents a methodology for quantitative assessment of the influence of technological heredity on the formation of quality parameters for surfaces of machine parts. An example of an estimation of influence factors of technological subsystems of processing by end milling processing by composite 10 and the subsequent diamond burnishing is presented.

  3. Effect of scan quality on diagnostic accuracy of spectral-domain optical coherence tomography in glaucoma.

    PubMed

    Rao, Harsha L; Addepalli, Uday K; Yadav, Ravi K; Senthil, Sirisha; Choudhari, Nikhil S; Garudadri, Chandra S

    2014-03-01

    To evaluate the effect of scan quality on the diagnostic accuracies of optic nerve head (ONH), retinal nerve fiber layer (RNFL), and ganglion cell complex (GCC) parameters of spectral-domain optical coherence tomography (SD OCT) in glaucoma. Cross-sectional study. Two hundred fifty-two eyes of 183 control subjects (mean deviation [MD]: -1.84 dB) and 207 eyes of 159 glaucoma patients (MD: -7.31 dB) underwent ONH, RNFL, and GCC scanning with SD OCT. Scan quality of SD OCT images was based on signal strength index (SSI) values. Influence of SSI on diagnostic accuracy of SD OCT was evaluated by receiver operating characteristic (ROC) regression. Diagnostic accuracies of all SD OCT parameters were better when the SSI values were higher. This effect was statistically significant (P < .05) for ONH and RNFL but not for GCC parameters. In mild glaucoma (MD of -5 dB), area under ROC curve (AUC) for rim area, average RNFL thickness, and average GCC thickness parameters improved from 0.651, 0.678, and 0.726, respectively, at an SSI value of 30 to 0.873, 0.962, and 0.886, respectively, at an SSI of 70. AUCs of the same parameters in advanced glaucoma (MD of -15 dB) improved from 0.747, 0.890, and 0.873, respectively, at an SSI value of 30 to 0.922, 0.994, and 0.959, respectively, at an SSI of 70. Diagnostic accuracies of SD OCT parameters in glaucoma were significantly influenced by the scan quality even when the SSI values were within the manufacturer-recommended limits. These results should be considered while interpreting the SD OCT scans for glaucoma. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Classification of edible oils and modeling of their physico-chemical properties by chemometric methods using mid-IR spectroscopy

    NASA Astrophysics Data System (ADS)

    Luna, Aderval S.; da Silva, Arnaldo P.; Ferré, Joan; Boqué, Ricard

    This research work describes two studies for the classification and characterization of edible oils and its quality parameters through Fourier transform mid infrared spectroscopy (FT-mid-IR) together with chemometric methods. The discrimination of canola, sunflower, corn and soybean oils was investigated using SVM-DA, SIMCA and PLS-DA. Using FT-mid-IR, DPLS was able to classify 100% of the samples from the validation set, but SIMCA and SVM-DA were not. The quality parameters: refraction index and relative density of edible oils were obtained from reference methods. Prediction models for FT-mid-IR spectra were calculated for these quality parameters using partial least squares (PLS) and support vector machines (SVM). Several preprocessing alternatives (first derivative, multiplicative scatter correction, mean centering, and standard normal variate) were investigated. The best result for the refraction index was achieved with SVM as well as for the relative density except when the preprocessing combination of mean centering and first derivative was used. For both of quality parameters, the best results obtained for the figures of merit expressed by the root mean square error of cross validation (RMSECV) and prediction (RMSEP) were equal to 0.0001.

  5. Natural organic matter (NOM) adsorption to multi-walled carbon nanotubes: effect of NOM characteristics and water quality parameters.

    PubMed

    Hyung, Hoon; Kim, Jae-Hong

    2008-06-15

    The effect of natural organic matter (NOM) characteristics and water quality parameters on NOM adsorption to multiwalled carbon nanotubes (MWNT) was investigated. Isotherm experiment results were fitted well with a modified Freundlich isotherm model that took into account the heterogeneous nature of NOM. The preferential adsorption of the higher molecular weight fraction of NOM was observed by size exclusion chromatographic analysis. Experiments performed with various NOM samples suggested that the degree of NOM adsorption varied greatly depending on the type of NOM and was proportional to the aromatic carbon content of NOM. The NOM adsorption to MWNT was also dependent on water quality parameters: adsorption increased as pH decreased and ionic strength increased. As a result of NOM adsorption to MWNT, a fraction of MWNT formed a stable suspension in water and the concentration of MWNT suspension depended on the amount of NOM adsorbed per unit mass of MWNT. The amount of MWNT suspended in water was also affected by ionic strength and pH. The findings in this study suggested that the fate and transport of MWNT in natural systems would be largely influenced by NOM characteristics and water quality parameters.

  6. Effect of dietary plant extract on meat quality and sensory parameters of meat from Equidae.

    PubMed

    Rossi, Raffaella; Ratti, Sabrina; Pastorelli, Grazia; Maghin, Federica; Martemucci, Giovanni; Casamassima, Donato; D'Alessandro, Angela Gabriella; Corino, Carlo

    2017-11-01

    Plant extracts as Lippia spp. have been proven antioxidant properties. Recent studies have been shown that dietary supplementation with plant extracts is able to enhance meat quality parameters. Studies regarding meat quality in Equidae are limited. The effect of dietary plant extract (PE), containing verbascoside, on meat quality, oxidative stability and sensory parameters of Longissimus Lumborum (LL) muscle in Equidae was studied. Dietary treatment did not affect (P > 0.05) pH, colour indices and chemical parameters of muscle in both donkey and horse. Dietary PE improved (P < 0.01) oxidative stability in donkey muscle during refrigerated storage. Sensory characteristics of LL muscle were positively affected (P < 0.05) by dietary PE in both donkey and horse. In particular, colour, taste and texture were enhanced in LL muscle from animals fed PE. Oxidative stability was lower (P < 0.05) in LL muscle of horse than that of donkey. Dietary plant extract, containing verbascoside, can be considered as a natural source of antioxidants, and is also able to improve oxidative stability of donkey meat and to affect the sensory attributes of Equidae meat. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  7. Evaluation of physico-chemical characteristics of groundwater of Company Bagh pumping station and its six distribution points in old Jammu City, India.

    PubMed

    Khajuria, Meenakshi; Dutta, S P S

    2011-10-01

    To assess water quality of Company Bagh pumping station and its six distribution points, viz. Parade Ground, Mohalla Paharian, Purani Mandi, Malhotrian Street, Raghunathpura and Hari Market in old Jammu city of India, water parameters viz. temperature, turbidity, pH, electrical conductivity, free carbon dioxide, dissolved oxygen, biochemical oxygen demand, chemical oxygen demand, bicarbonate, chloride, calcium, magnesium, total hardness, sodium, potassium, sulphate, silicate, nitrate, phosphate, iron, copper, zinc, lead and chromium were analyzed during the years 2000-2001/2001-2002. There was alteration in water quality parameters in the distribution system caused by entry of sewage, soil, etc. through dislocation, cracks, valve regulators/turncock, defective joints, breakage, etc. in the pipes through crossing and deposits of biofilms inside the pipes, dead ends and their degradation through microbes. Comparison of water quality with National and International Standards revealed that all the parameters were within permissible limits of drinking water standards. Water Quality Index (WQI) of various physico-chemical parameters revealed that the water of Company Bagh pumping station and its six distribution points was fit for human consumption as it was found under the category of good (WQI < 50).

  8. Effect of wheat flour characteristics on sponge cake quality.

    PubMed

    Moiraghi, Malena; de la Hera, Esther; Pérez, Gabriela T; Gómez, Manuel

    2013-02-01

    To select the flour parameters that relate strongly to cake-making performance, in this study the relationship between sponge cake quality, solvent retention capacity (SRC) profile and flour physicochemical characteristics was investigated using 38 soft wheat samples of different origins. Particle size average, protein, damaged starch, water-soluble pentosans, total pentosans, SRC and pasting properties were analysed. Sponge cake volume and crumb texture were measured to evaluate cake quality. Cluster analysis was applied to assess differences in flour quality parameters among wheat lines based on the SRC profile. Cluster 1 showed significantly higher sponge cake volume and crumb softness, finer particle size and lower SRC sucrose, SRC carbonate, SRC water, damaged starch and protein content. Particle size, damaged starch, protein, thickening capacity and SRC parameters correlated negatively with sponge cake volume, while total pentosans and pasting temperature showed the opposite effect. The negative correlations between cake volume and SRC parameters along with the cluster analysis results indicated that flours with smaller particle size, lower absorption capacity and higher pasting temperature had better cake-making performance. Some simple analyses, such as SRC, particle size distribution and pasting properties, may help to choose flours suitable for cake making. Copyright © 2012 Society of Chemical Industry.

  9. MOVES sensitivity analysis update : Transportation Research Board Summer Meeting 2012 : ADC-20 Air Quality Committee

    DOT National Transportation Integrated Search

    2012-01-01

    OVERVIEW OF PRESENTATION : Evaluation Parameters : EPAs Sensitivity Analysis : Comparison to Baseline Case : MOVES Sensitivity Run Specification : MOVES Sensitivity Input Parameters : Results : Uses of Study

  10. R2 Water Quality Portal Monitoring Stations

    EPA Pesticide Factsheets

    The Water Quality Data Portal (WQP) provides an easy way to access data stored in various large water quality databases. The WQP provides various input parameters on the form including location, site, sampling, and date parameters to filter and customize the returned results. The The Water Quality Portal (WQP) is a cooperative service sponsored by the United States Geological Survey (USGS), the Environmental Protection Agency (EPA) and the National Water Quality Monitoring Council (NWQMC) that integrates publicly available water quality data from the USGS National Water Information System (NWIS) the EPA STOrage and RETrieval (STORET) Data Warehouse, and the USDA ARS Sustaining The Earth??s Watersheds - Agricultural Research Database System (STEWARDS).

  11. Factors influencing microinjection molding replication quality

    NASA Astrophysics Data System (ADS)

    Vera, Julie; Brulez, Anne-Catherine; Contraires, Elise; Larochette, Mathieu; Trannoy-Orban, Nathalie; Pignon, Maxime; Mauclair, Cyril; Valette, Stéphane; Benayoun, Stéphane

    2018-01-01

    In recent years, there has been increased interest in producing and providing high-precision plastic parts that can be manufactured by microinjection molding: gears, pumps, optical grating elements, and so on. For all of these applications, the replication quality is essential. This study has two goals: (1) fabrication of high-precision parts using the conventional injection molding machine; (2) identification of robust parameters that ensure production quality. Thus, different technological solutions have been used: cavity vacuuming and the use of a mold coated with DLC or CrN deposits. AFM and SEM analyses were carried out to characterize the replication profile. The replication quality was studied in terms of the process parameters, coated and uncoated molds and crystallinity of the polymer. Specific studies were processed to quantify the replicability of injection molded parts (ABS, PC and PP). Analysis of the Taguchi experimental designs permits prioritization of the impact of each parameter on the replication quality. A discussion taking into account these new parameters and the thermal and spreading properties on the coatings is proposed. It appeared that, in general, increasing the mold temperature improves the molten polymer fill in submicron features except for the steel insert (for which the presence of a vacuum is the most important factor). Moreover, the DLC coating was the best coating to increase the quality of the replication. This result could be explained by the lower thermal diffusivity of this coating. We noted that the viscosity of the polymers is not a primordial factor of the replication quality.

  12. An enhanced PM 2.5 air quality forecast model based on nonlinear regression and back-trajectory concentrations

    NASA Astrophysics Data System (ADS)

    Cobourn, W. Geoffrey

    2010-08-01

    An enhanced PM 2.5 air quality forecast model based on nonlinear regression (NLR) and back-trajectory concentrations has been developed for use in the Louisville, Kentucky metropolitan area. The PM 2.5 air quality forecast model is designed for use in the warm season, from May through September, when PM 2.5 air quality is more likely to be critical for human health. The enhanced PM 2.5 model consists of a basic NLR model, developed for use with an automated air quality forecast system, and an additional parameter based on upwind PM 2.5 concentration, called PM24. The PM24 parameter is designed to be determined manually, by synthesizing backward air trajectory and regional air quality information to compute 24-h back-trajectory concentrations. The PM24 parameter may be used by air quality forecasters to adjust the forecast provided by the automated forecast system. In this study of the 2007 and 2008 forecast seasons, the enhanced model performed well using forecasted meteorological data and PM24 as input. The enhanced PM 2.5 model was compared with three alternative models, including the basic NLR model, the basic NLR model with a persistence parameter added, and the NLR model with persistence and PM24. The two models that included PM24 were of comparable accuracy. The two models incorporating back-trajectory concentrations had lower mean absolute errors and higher rates of detecting unhealthy PM2.5 concentrations compared to the other models.

  13. Outpatient management of oral vitamin K antagonist therapy: defining and measuring high-quality management.

    PubMed

    Phillips, Katherine W; Ansell, Jack

    2008-01-01

    Oral anticoagulation therapy with warfarin is the mainstay of prevention and treatment of thromboembolic disease. However, it remains one of the leading causes of harmful medication errors and medication-related adverse events. The beneficial outcomes of oral anticoagulation therapy are directly dependent upon the quality of dose and anticoagulation management, but the literature is not robust with regards to what constitutes such management. This review focuses on, and attempts to define, the parameters of high-quality anticoagulation management and identifies the appropriate outcome measures constituting high-quality management. Elements discussed include the most fundamental measure, time in therapeutic range, along with other parameters including therapy initiation, time to therapeutic range, dosing management when patients are not in therapeutic range, perioperative dosing management, patient education, and other important outcome measures. Healthcare providers who manage oral anticoagulation therapy should utilize these parameters as a measure of their performance in an effort to achieve high-quality anticoagulation management.

  14. Pre-slaughter stress and pork quality

    NASA Astrophysics Data System (ADS)

    Stajković, S.; Teodorović, V.; Baltić, M.; Karabasil, N.

    2017-09-01

    Stress is an inevitable consequence of handling of animals for slaughter. Stress conditions during transport, lairage and at slaughter induce undesirable effects on the end quality of meat such as pale, soft, exudative meat and dark firm dry meat. Hence, it is very important to define appropriate parameters for objective assessment of level of stress. Attempts to define measures of stress have been difficult and no physiological parameter has been successfully used to evaluate stress situations. One physiological change in swine associated with animal handling stress and with pork quality is an increase in blood lactate concentration. Plasma cortisol was thought to be an appropriate indicator of stress, but the concentration was not consistently changed by different stressors. Therefore, finding alternative parameters reacting to stressors, such as acute phase proteins, would be of great value for the objective evaluation of level of stress and meat quality. As the stress during pre-slaughter handling is unavoidable, the final goal is to improve transport and slaughter conditions for the animal and, as a consequence, meat quality and animal welfare.

  15. Downstream processing from hot-melt extrusion towards tablets: A quality by design approach.

    PubMed

    Grymonpré, W; Bostijn, N; Herck, S Van; Verstraete, G; Vanhoorne, V; Nuhn, L; Rombouts, P; Beer, T De; Remon, J P; Vervaet, C

    2017-10-05

    Since the concept of continuous processing is gaining momentum in pharmaceutical manufacturing, a thorough understanding on how process and formulation parameters can impact the critical quality attributes (CQA) of the end product is more than ever required. This study was designed to screen the influence of process parameters and drug load during HME on both extrudate properties and tableting behaviour of an amorphous solid dispersion formulation using a quality-by-design (QbD) approach. A full factorial experimental design with 19 experiments was used to evaluate the effect of several process variables (barrel temperature: 160-200°C, screw speed: 50-200rpm, throughput: 0.2-0.5kg/h) and drug load (0-20%) as formulation parameter on the hot-melt extrusion (HME) process, extrudate and tablet quality of Soluplus ® -Celecoxib amorphous solid dispersions. A prominent impact of the formulation parameter on the CQA of the extrudates (i.e. solid state properties, moisture content, particle size distribution) and tablets (i.e. tabletability, compactibility, fragmentary behaviour, elastic recovery) was discovered. The resistance of the polymer matrix to thermo-mechanical stress during HME was confirmed throughout the experimental design space. In addition, the suitability of Raman spectroscopy as verification method for the active pharmaceutical ingredient (API) concentration in solid dispersions was evaluated. Incorporation of the Raman spectroscopy data in a PLS model enabled API quantification in the extrudate powders with none of the DOE-experiments resulting in extrudates with a CEL content deviating>3% of the label claim. This research paper emphasized that HME is a robust process throughout the experimental design space for obtaining amorphous glassy solutions and for tabletting of such formulations since only minimal impact of the process parameters was detected on the extrudate and tablet properties. However, the quality of extrudates and tablets can be optimized by adjusting specific formulations parameters (e.g. drug load). Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Bayesian Parameter Estimation for Heavy-Duty Vehicles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, Eric; Konan, Arnaud; Duran, Adam

    2017-03-28

    Accurate vehicle parameters are valuable for design, modeling, and reporting. Estimating vehicle parameters can be a very time-consuming process requiring tightly-controlled experimentation. This work describes a method to estimate vehicle parameters such as mass, coefficient of drag/frontal area, and rolling resistance using data logged during standard vehicle operation. The method uses Monte Carlo to generate parameter sets which is fed to a variant of the road load equation. Modeled road load is then compared to measured load to evaluate the probability of the parameter set. Acceptance of a proposed parameter set is determined using the probability ratio to the currentmore » state, so that the chain history will give a distribution of parameter sets. Compared to a single value, a distribution of possible values provides information on the quality of estimates and the range of possible parameter values. The method is demonstrated by estimating dynamometer parameters. Results confirm the method's ability to estimate reasonable parameter sets, and indicates an opportunity to increase the certainty of estimates through careful selection or generation of the test drive cycle.« less

  17. Identifyability measures to select the parameters to be estimated in a solid-state fermentation distributed parameter model.

    PubMed

    da Silveira, Christian L; Mazutti, Marcio A; Salau, Nina P G

    2016-07-08

    Process modeling can lead to of advantages such as helping in process control, reducing process costs and product quality improvement. This work proposes a solid-state fermentation distributed parameter model composed by seven differential equations with seventeen parameters to represent the process. Also, parameters estimation with a parameters identifyability analysis (PIA) is performed to build an accurate model with optimum parameters. Statistical tests were made to verify the model accuracy with the estimated parameters considering different assumptions. The results have shown that the model assuming substrate inhibition better represents the process. It was also shown that eight from the seventeen original model parameters were nonidentifiable and better results were obtained with the removal of these parameters from the estimation procedure. Therefore, PIA can be useful to estimation procedure, since it may reduce the number of parameters that can be evaluated. Further, PIA improved the model results, showing to be an important procedure to be taken. © 2016 American Institute of Chemical Engineers Biotechnol. Prog., 32:905-917, 2016. © 2016 American Institute of Chemical Engineers.

  18. Instruments for Water Quality Monitoring

    ERIC Educational Resources Information Center

    Ballinger, Dwight G.

    1972-01-01

    Presents information regarding available instruments for industries and agencies who must monitor numerous aquatic parameters. Charts denote examples of parameters sampled, testing methods, range and accuracy of test methods, cost analysis, and reliability of instruments. (BL)

  19. Influence of Wire Electrical Discharge Machining (WEDM) process parameters on surface roughness

    NASA Astrophysics Data System (ADS)

    Yeakub Ali, Mohammad; Banu, Asfana; Abu Bakar, Mazilah

    2018-01-01

    In obtaining the best quality of engineering components, the quality of machined parts surface plays an important role. It improves the fatigue strength, wear resistance, and corrosion of workpiece. This paper investigates the effects of wire electrical discharge machining (WEDM) process parameters on surface roughness of stainless steel using distilled water as dielectric fluid and brass wire as tool electrode. The parameters selected are voltage open, wire speed, wire tension, voltage gap, and off time. Empirical model was developed for the estimation of surface roughness. The analysis revealed that off time has a major influence on surface roughness. The optimum machining parameters for minimum surface roughness were found to be at a 10 V open voltage, 2.84 μs off time, 12 m/min wire speed, 6.3 N wire tension, and 54.91 V voltage gap.

  20. Integrated hydraulic and organophosphate pesticide injection simulations for enhancing event detection in water distribution systems.

    PubMed

    Schwartz, Rafi; Lahav, Ori; Ostfeld, Avi

    2014-10-15

    As a complementary step towards solving the general event detection problem of water distribution systems, injection of the organophosphate pesticides, chlorpyrifos (CP) and parathion (PA), were simulated at various locations within example networks and hydraulic parameters were calculated over 24-h duration. The uniqueness of this study is that the chemical reactions and byproducts of the contaminants' oxidation were also simulated, as well as other indicative water quality parameters such as alkalinity, acidity, pH and the total concentration of free chlorine species. The information on the change in water quality parameters induced by the contaminant injection may facilitate on-line detection of an actual event involving this specific substance and pave the way to development of a generic methodology for detecting events involving introduction of pesticides into water distribution systems. Simulation of the contaminant injection was performed at several nodes within two different networks. For each injection, concentrations of the relevant contaminants' mother and daughter species, free chlorine species and water quality parameters, were simulated at nodes downstream of the injection location. The results indicate that injection of these substances can be detected at certain conditions by a very rapid drop in Cl2, functioning as the indicative parameter, as well as a drop in alkalinity concentration and a small decrease in pH, both functioning as supporting parameters, whose usage may reduce false positive alarms. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. The influence of Glu-1 and Glu-3 loci on dough rheology and bread-making properties in wheat (Triticum aestivum L.) doubled haploid lines.

    PubMed

    Langner, Monika; Krystkowiak, Karolina; Salmanowicz, Bolesław P; Adamski, Tadeusz; Krajewski, Paweł; Kaczmarek, Zygmunt; Surma, Maria

    2017-12-01

    The major determinants of wheat quality are Glu-1 and Glu-3 glutenin loci and environmental factors. Additive effects of alleles at the Glu-1 and Glu-3 loci, as well as their interactions, were evaluated for dough rheology and baking properties in four groups of wheat doubled haploid lines differing in high- and low-molecular-weight glutenin composition. Flour quality, Reomixer (Reologica Instruments, Lund, Sweden), dough extension, Farinograph (Brabender GmbH, Duisburg, Germany) and baking parameters were determined. Groups of lines with the alleles Glu-A3b and Glu-B3d were characterized by higher values of dough and baking parameters compared to those with the Glu-A3e and Glu-B3a alleles. Effects of interactions between allelic variants at the Glu-1 and Glu-3 loci on Reomixer parameters, dough extension tests and baking parameters were significant, although additive effects of individual alleles were not always significant. The allelic variants at Glu-B3 had a much greater effect on dough rheological parameters than the variants at Glu-A3 or Glu-D3 loci. The effect of allelic variations at the Glu-D3 loci on rheological parameters and bread-making quality was non-significant, whereas their interactions with a majority of alleles at the other Glu-1 × Glu-3 loci were significant. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  2. The effect of mimosa and syntan mixture on the quality of tanned red snapper leather

    NASA Astrophysics Data System (ADS)

    Pratama, M.; Sahubawa, L.; Pertiwiningrum, A.; Rahmadian, Y.; Puspita, I. D.

    2018-03-01

    This study aimed to determine the effect of syntan and mimosa combination on the quality of tanned red snapper leather. The study was designed using complete randomized design (CRD) and the advanced test of Least Significant Difference (LSD) with three replications and three treatments of combined syntan and mimosa, namely: p1 (4 % syntan, 5 % mimosa), p2 (8 % syntan, 5 %mimosa), p3 (12 % syntan, 5 % mimosa). Data were analyzed using SPSS 18. The measured parameters were tensile strength (N·cm-2), elongation (%), tear strength (N·cm-1), enervation (mm), wrinkle temperature (°C), fat/oil content (%) and water content (%). The results indicate that the combined syntan and mimosa tanners gave no significant effect on the physical parameters (tensile strength, elongation, tear strength, enervation and wrinkle temperature) and chemical parameters (moisture and fat/oil). All treatments (p1, p2 and p3) met the Indonesian National Standard (SNI) 06-4586-1998 for chrome tanned freshwater snake leather for the parameters of tensile strength, tear strength, enervation, wrinkle temperature and moisture. The parameter of elongation and fat/oil content did not meet with the SNI 06-4586-1998. Among the three combinations of a tanner, syntan 4 % and mimosa 5 % treatment gave the best leather quality.

  3. Study of optimal laser parameters for cutting QFN packages by Taguchi's matrix method

    NASA Astrophysics Data System (ADS)

    Li, Chen-Hao; Tsai, Ming-Jong; Yang, Ciann-Dong

    2007-06-01

    This paper reports the study of optimal laser parameters for cutting QFN (Quad Flat No-lead) packages by using a diode pumped solid-state laser system (DPSSL). The QFN cutting path includes two different materials, which are the encapsulated epoxy and a copper lead frame substrate. The Taguchi's experimental method with orthogonal array of L 9(3 4) is employed to obtain optimal combinatorial parameters. A quantified mechanism was proposed for examining the laser cutting quality of a QFN package. The influences of the various factors such as laser current, laser frequency, and cutting speed on the laser cutting quality is also examined. From the experimental results, the factors on the cutting quality in the order of decreasing significance are found to be (a) laser frequency, (b) cutting speed, and (c) laser driving current. The optimal parameters were obtained at the laser frequency of 2 kHz, the cutting speed of 2 mm/s, and the driving current of 29 A. Besides identifying this sequence of dominance, matrix experiment also determines the best level for each control factor. The verification experiment confirms that the application of laser cutting technology to QFN is very successfully by using the optimal laser parameters predicted from matrix experiments.

  4. Comparison of detection limits in environmental analysis--is it possible? An approach on quality assurance in the lower working range by verification.

    PubMed

    Geiss, S; Einax, J W

    2001-07-01

    Detection limit, reporting limit and limit of quantitation are analytical parameters which describe the power of analytical methods. These parameters are used for internal quality assurance and externally for competing, especially in the case of trace analysis in environmental compartments. The wide variety of possibilities for computing or obtaining these measures in literature and in legislative rules makes any comparison difficult. Additionally, a host of terms have been used within the analytical community to describe detection and quantitation capabilities. Without trying to create an order for the variety of terms, this paper is aimed at providing a practical proposal for answering the main questions for the analysts concerning quality measures above. These main questions and related parameters were explained and graphically demonstrated. Estimation and verification of these parameters are the two steps to get real measures. A rule for a practical verification is given in a table, where the analyst can read out what to measure, what to estimate and which criteria have to be fulfilled. In this manner verified parameters detection limit, reporting limit and limit of quantitation now are comparable and the analyst himself is responsible to the unambiguity and reliability of these measures.

  5. A comparative study of kinetic and connectionist modeling for shelf-life prediction of Basundi mix.

    PubMed

    Ruhil, A P; Singh, R R B; Jain, D K; Patel, A A; Patil, G R

    2011-04-01

    A ready-to-reconstitute formulation of Basundi, a popular Indian dairy dessert was subjected to storage at various temperatures (10, 25 and 40 °C) and deteriorative changes in the Basundi mix were monitored using quality indices like pH, hydroxyl methyl furfural (HMF), bulk density (BD) and insolubility index (II). The multiple regression equations and the Arrhenius functions that describe the parameters' dependence on temperature for the four physico-chemical parameters were integrated to develop mathematical models for predicting sensory quality of Basundi mix. Connectionist model using multilayer feed forward neural network with back propagation algorithm was also developed for predicting the storage life of the product employing artificial neural network (ANN) tool box of MATLAB software. The quality indices served as the input parameters whereas the output parameters were the sensorily evaluated flavour and total sensory score. A total of 140 observations were used and the prediction performance was judged on the basis of per cent root mean square error. The results obtained from the two approaches were compared. Relatively lower magnitudes of percent root mean square error for both the sensory parameters indicated that the connectionist models were better fitted than kinetic models for predicting storage life.

  6. Groundwater quality assessment of urban Bengaluru using multivariate statistical techniques

    NASA Astrophysics Data System (ADS)

    Gulgundi, Mohammad Shahid; Shetty, Amba

    2018-03-01

    Groundwater quality deterioration due to anthropogenic activities has become a subject of prime concern. The objective of the study was to assess the spatial and temporal variations in groundwater quality and to identify the sources in the western half of the Bengaluru city using multivariate statistical techniques. Water quality index rating was calculated for pre and post monsoon seasons to quantify overall water quality for human consumption. The post-monsoon samples show signs of poor quality in drinking purpose compared to pre-monsoon. Cluster analysis (CA), principal component analysis (PCA) and discriminant analysis (DA) were applied to the groundwater quality data measured on 14 parameters from 67 sites distributed across the city. Hierarchical cluster analysis (CA) grouped the 67 sampling stations into two groups, cluster 1 having high pollution and cluster 2 having lesser pollution. Discriminant analysis (DA) was applied to delineate the most meaningful parameters accounting for temporal and spatial variations in groundwater quality of the study area. Temporal DA identified pH as the most important parameter, which discriminates between water quality in the pre-monsoon and post-monsoon seasons and accounts for 72% seasonal assignation of cases. Spatial DA identified Mg, Cl and NO3 as the three most important parameters discriminating between two clusters and accounting for 89% spatial assignation of cases. Principal component analysis was applied to the dataset obtained from the two clusters, which evolved three factors in each cluster, explaining 85.4 and 84% of the total variance, respectively. Varifactors obtained from principal component analysis showed that groundwater quality variation is mainly explained by dissolution of minerals from rock water interactions in the aquifer, effect of anthropogenic activities and ion exchange processes in water.

  7. Quality parameters and antioxidant and antibacterial properties of some Mexican honeys.

    PubMed

    Rodríguez, Beatriz A; Mendoza, Sandra; Iturriga, Montserrat H; Castaño-Tostado, Eduardo

    2012-01-01

    A total of 14 Mexican honeys were screened for quality parameters including color, moisture, proline, and acidity. Antioxidant properties of complete honey and its methanolic extracts were evaluated by the DPPH, ABTS, and FRAP assays. In addition, the antimicrobial activity of complete honeys against Bacillus cereus ATCC 10876, Listeria monocytogenes Scott A, Salmonella Typhimurium ATCC 14028, and Sthapylococcus aureus ATCC 6538 was determined. Most of honeys analyzed showed values within quality parameters established by the Codex Alimentarius Commission in 2001. Eucalyptus flower honey and orange blossom honey showed the highest phenolic contents and antioxidant capacity. Bell flower, orange blossom, and eucalyptus flower honeys inhibited the growth of the 4 evaluated microorganisms. The remaining honeys affected at least 1 of the estimated growth parameters (increased lag phase, decreased growth rate, and/or maximum population density). Microorganism sensitivity to the antimicrobial activity of honeys followed the order B. cereus > L. monocytogenes > Salmonella Typhimurium > S. aureus. The monofloral honey samples from orange blossoms, and eucalyptus flowers demonstrated to be good sources of antioxidant and antimicrobial compounds. All the Mexican honey samples examined proved to be good sources of antioxidants and antimicrobial agents that might serve to maintain health and protect against several diseases. The results of the study showed that Mexican honeys display good quality parameters and antioxidant and antimicrobial activities. Mexican honey can be used as an additive in the food industry to increase the nutraceutical value of products. © 2011 Institute of Food Technologists®

  8. A preliminary study of environmental parameters associated with the feasibility of a polygeneration plant at Kennedy Space Center

    NASA Technical Reports Server (NTRS)

    Barnes, G. D.

    1982-01-01

    The feasibility of a polygeneration plant at Kennedy Space Center was studied. Liquid hydrogen and gaseous nitrogen are the two principal products in consideration. Environmental parameters (air quality, water quality, biological diversity and hazardous waste disposal) necessary for the feasibility study were investigated. A National Environmental Policy Act (NEPA) project flow sheet was to be formulated for the environmental impact statement. Water quality criteria for Florida waters were to be established.

  9. Impact of city effluents on water quality of Indus River: assessment of temporal and spatial variations in the southern region of Khyber Pakhtunkhwa, Pakistan.

    PubMed

    Khan, Ilham; Khan, Azim; Khan, Muhammad Sohail; Zafar, Shabnam; Hameed, Asma; Badshah, Shakeel; Rehman, Shafiq Ur; Ullah, Hidayat; Yasmeen, Ghazala

    2018-04-04

    The impact of city effluents on water quality of Indus River was assessed in the southern region of Khyber Pakhtunkhwa, Pakistan. Water samples were collected in dry (DS) and wet (WS) seasons from seven sampling zones along Indus River and the physical, bacteriological, and chemical parameters determining water quality were quantified. There were marked temporal and spatial variations in the water quality of Indus River. The magnitude of pollution was high in WS compared with DS. The quality of water varied across the sampling zones, and it greatly depended upon the nature of effluents entering the river. Water samples exceeded the WHO permissible limits for pH, EC, TDS, TS, TSS, TH, DO, BOD, COD, total coliforms, Escherichia coli, Ca 2+ , Mg 2+ , NO 3 - , and PO 4 2- . Piper analysis indicated that water across the seven sampling zones along Indus River was alkaline in nature. Correlation analyses indicated that EC, TDS, TS, TH, DO, BOD, and COD may be considered as key physical parameters, while Na + , K + , Ca 2+ , Mg 2+ , Cl - , F - , NO 3 - , PO 4 2- , and SO 4 2- as key chemical parameters determining water quality, because they were strongly correlated (r > 0.70) with most of the parameters studied. Cluster analysis indicated that discharge point at Shami Road is the major source of pollution impairing water quality of Indus River. Wastewater treatment plants must be installed at all discharge points along Indus River for protecting the quality of water of this rich freshwater resource in Pakistan.

  10. Effect of cattle management practices on raw milk quality on farms operating in a two-stage dairy chain.

    PubMed

    Sraïri, M T; Benhouda, H; Kuper, M; Le Gal, P Y

    2009-02-01

    In many developing countries, milk production varies greatly according to farm size, cattle breed, and milking practices. However, production systems often are dominated by smallholder farms. Therefore, relatively small volumes of milk are delivered daily from numerous farms to intermediate cooperatives which supply industrial units. This paper argues that in such two-stage dairy chains, milk quality could be improved by focusing on farming practices rather than on the testing of individual deliveries. Indeed, it is difficult to analyze their quality due to technical, economic, and logistic limitations. The objective of this study is to link on-farm practices with milk chemical quality parameters (fat and protein) and hygienic quality criteria (Aerobic Plate Count, APC and Coliforms). Cattle management practices were monitored monthly over one year on 23 farms located on an irrigation scheme in Morocco. 276 milk samples were analyzed. The monthly variability of milk quality parameters was then characterized. Results show that average cow milk chemical parameters vary within a normal range. They remain primarily linked to the genetic type of cows, the lactation stage, and the conversion of feed concentrates' net energy into milk. Overall milk hygienic quality was poor (APC and Coliforms counts were 100 fold international norms), due essentially to a lack of hygiene and inadequate milking conditions (hands, udder, and teat washing, type of bucket used, dirtiness of cows...). It is suggested that a close monitoring of herd management practices may allow the indirect control of milk quality parameters, thereby avoiding costly analyses of numerous smallholder milk deliveries.

  11. Comparison of phase unwrapping algorithms for topography reconstruction based on digital speckle pattern interferometry

    NASA Astrophysics Data System (ADS)

    Li, Yuanbo; Cui, Xiaoqian; Wang, Hongbei; Zhao, Mengge; Ding, Hongbin

    2017-10-01

    Digital speckle pattern interferometry (DSPI) can diagnose the topography evolution in real-time, continuous and non-destructive, and has been considered as a most promising technique for Plasma-Facing Components (PFCs) topography diagnostic under the complicated environment of tokamak. It is important for the study of digital speckle pattern interferometry to enhance speckle patterns and obtain the real topography of the ablated crater. In this paper, two kinds of numerical model based on flood-fill algorithm has been developed to obtain the real profile by unwrapping from the wrapped phase in speckle interference pattern, which can be calculated through four intensity images by means of 4-step phase-shifting technique. During the process of phase unwrapping by means of flood-fill algorithm, since the existence of noise pollution, and other inevitable factors will lead to poor quality of the reconstruction results, this will have an impact on the authenticity of the restored topography. The calculation of the quality parameters was introduced to obtain the quality-map from the wrapped phase map, this work presents two different methods to calculate the quality parameters. Then quality parameters are used to guide the path of flood-fill algorithm, and the pixels with good quality parameters are given priority calculation, so that the quality of speckle interference pattern reconstruction results are improved. According to the comparison between the flood-fill algorithm which is suitable for speckle pattern interferometry and the quality-guided flood-fill algorithm (with two different calculation approaches), the errors which caused by noise pollution and the discontinuous of the strips were successfully reduced.

  12. Ambient air pollution and semen quality.

    PubMed

    Nobles, Carrie J; Schisterman, Enrique F; Ha, Sandie; Kim, Keewan; Mumford, Sunni L; Buck Louis, Germaine M; Chen, Zhen; Liu, Danping; Sherman, Seth; Mendola, Pauline

    2018-05-01

    Ambient air pollution is associated with systemic increases in oxidative stress, to which sperm are particularly sensitive. Although decrements in semen quality represent a key mechanism for impaired fecundability, prior research has not established a clear association between air pollution and semen quality. To address this, we evaluated the association between ambient air pollution and semen quality among men with moderate air pollution exposure. Of 501 couples in the LIFE study, 467 male partners provided one or more semen samples. Average residential exposure to criteria air pollutants and fine particle constituents in the 72 days before ejaculation was estimated using modified Community Multiscale Air Quality models. Generalized estimating equation models estimated the association between air pollutants and semen quality parameters (volume, count, percent hypo-osmotic swollen, motility, sperm head, morphology and sperm chromatin parameters). Models adjusted for age, body mass index, smoking and season. Most associations between air pollutants and semen parameters were small. However, associations were observed for an interquartile increase in fine particulates ≤2.5 µm and decreased sperm head size, including -0.22 (95% CI -0.34, -0.11) µm 2 for area, -0.06 (95% CI -0.09, -0.03) µm for length and -0.09 (95% CI -0.19, -0.06) µm for perimeter. Fine particulates were also associated with 1.03 (95% CI 0.40, 1.66) greater percent sperm head with acrosome. Air pollution exposure was not associated with semen quality, except for sperm head parameters. Moderate levels of ambient air pollution may not be a major contributor to semen quality. Published by Elsevier Inc.

  13. ATM Quality of Service Parameters at 45 Mbps Using a Satellite Emulator: Laboratory Measurements

    NASA Technical Reports Server (NTRS)

    Ivancic, William D.; Bobinsky, Eric A.

    1997-01-01

    Results of 45-Mbps DS3 intermediate-frequency loopback measurements of asynchronous transfer mode (ATM) quality of service parameters (cell error ratio and cell loss ratio) are presented. These tests, which were conducted at the NASA Lewis Research Center in support of satellite-ATM interoperability research, represent initial efforts to quantify the minimum parameters for stringent ATM applications, such as MPEG-1 and MPEG-2 video transmission. Portions of these results were originally presented to the International Telecommunications Union's ITU-R Working Party 4B in February 1996 in support of their Draft Preliminary Recommendation on the Transmission of ATM Traffic via Satellite.

  14. Method of control position of laser focus during surfacing teeth of cutters

    NASA Astrophysics Data System (ADS)

    Zvezdin, V. V.; Hisamutdinov, R. M.; Rakhimov, R. R.; Israfilov, I. H.; Akhtiamov, R. F.

    2017-09-01

    Providing the quality laser of surfacing the edges of teeth requires control not only the energy of the radiation parameters, but also the position of the focal spot. The control channel of position of laser focus during surfacing, which determines the parameters of quality of the deposited layer, was calculated in the work. The parameters of the active opto-electronic system for the subsystem adjust the focus position relative to the deposited layer with a laser illumination of the cutting edges the teeth cutters were calculated, the model of a control channel based on thermal phenomena occurring in the zone of surfacing was proposed.

  15. Development of a laboratory prototype water quality monitoring system suitable for use in zero gravity

    NASA Technical Reports Server (NTRS)

    Misselhorn, J. E.; Witz, S.; Hartung, W. H.

    1973-01-01

    The development of a laboratory prototype water quality monitoring system for use in the evaluation of candidate water recovery systems and for study of techniques for measuring potability parameters is reported. Sensing techniques for monitoring of the most desirable parameters are reviewed in terms of their sensitivities and complexities, and their recommendations for sensing techniques are presented. Rationale for selection of those parameters to be monitored (pH, specific conductivity, Cr(+6), I2, total carbon, and bacteria) in a next generation water monitor is presented along with an estimate of flight system specifications. A master water monitor development schedule is included.

  16. Organic food quality: a framework for concept, definition and evaluation from the European perspective.

    PubMed

    Kahl, Johannes; Baars, Ton; Bügel, Susanne; Busscher, Nicolaas; Huber, Machteld; Kusche, Daniel; Rembiałkowska, Ewa; Schmid, Otto; Seidel, Kathrin; Taupier-Letage, Bruno; Velimirov, Alberta; Załecka, Aneta

    2012-11-01

    Consumers buy organic food because they believe in the high quality of the product. Furthermore, the EU legal regulatory framework for organic food and farming defines high quality of the products as an important goal of production. A major challenge is the need to define food quality concepts and methods for determination. A background is described which allows embedding of the quality definitions as well as evaluation methods into a conceptual framework connected to the vision and mission of organic agriculture and food production. Organic food quality is defined through specific aspects and criteria. For evaluation each criterion has to be described by indicators. The determination of indicators should be through parameters, where parameters are described by methods. Conversely, the conceptual framework is described according to underlying principles and starting definitions are given, but further work has do be done on the detailed scientific description of the indicators. Furthermore, parameters have to be defined for the evaluation of suitability of these indicators for organic food production. Copyright © 2012 Society of Chemical Industry.

  17. Production of a water quality map of Saginaw Bay by computer processing of LANDSAT-2 data

    NASA Technical Reports Server (NTRS)

    Mckeon, J. B.; Rogers, R. H.; Smith, V. E.

    1977-01-01

    Surface truth and LANDSAT measurements collected July 31, 1975, for Saginaw Bay were used to demonstrate a technique for producing a color coded water quality map. On this map, color was used as a code to quantify five discrete ranges in the following water quality parameters: (1) temperature, (2) Secchi depth, (3) chloride, (4) conductivity, (5) total Kjeldahl nitrogen, (6) total phosphorous, (7)chlorophyll a, (8) total solids and (9) suspended solids. The LANDSAT and water quality relationship was established through the use of a set of linear regression equations where the water quality parameters are the dependent variables and LANDSAT measurements are the independent variables. Although the procedure is scene and surface truth dependent, it provides both a basis for extrapolating water quality parameters from point samples to unsampled areas and a synoptic view of water mass boundaries over the 3000 sq. km bay area made from one day's ship data that is superior, in many ways, to the traditional machine contoured maps made from three day's ship data.

  18. Quality Control Analysis of Selected Aspects of Programs Administered by the Bureau of Student Financial Assistance. Task 1 and Quality Control Sample; Error-Prone Modeling Analysis Plan.

    ERIC Educational Resources Information Center

    Saavedra, Pedro; And Others

    Parameters and procedures for developing an error-prone model (EPM) to predict financial aid applicants who are likely to misreport on Basic Educational Opportunity Grant (BEOG) applications are introduced. Specifications to adapt these general parameters to secondary data analysis of the Validation, Edits, and Applications Processing Systems…

  19. Multi-Response Parameter Interval Sensitivity and Optimization for the Composite Tape Winding Process.

    PubMed

    Deng, Bo; Shi, Yaoyao; Yu, Tao; Kang, Chao; Zhao, Pan

    2018-01-31

    The composite tape winding process, which utilizes a tape winding machine and prepreg tapes, provides a promising way to improve the quality of composite products. Nevertheless, the process parameters of composite tape winding have crucial effects on the tensile strength and void content, which are closely related to the performances of the winding products. In this article, two different object values of winding products, including mechanical performance (tensile strength) and a physical property (void content), were respectively calculated. Thereafter, the paper presents an integrated methodology by combining multi-parameter relative sensitivity analysis and single-parameter sensitivity analysis to obtain the optimal intervals of the composite tape winding process. First, the global multi-parameter sensitivity analysis method was applied to investigate the sensitivity of each parameter in the tape winding processing. Then, the local single-parameter sensitivity analysis method was employed to calculate the sensitivity of a single parameter within the corresponding range. Finally, the stability and instability ranges of each parameter were distinguished. Meanwhile, the authors optimized the process parameter ranges and provided comprehensive optimized intervals of the winding parameters. The verification test validated that the optimized intervals of the process parameters were reliable and stable for winding products manufacturing.

  20. Multi-Response Parameter Interval Sensitivity and Optimization for the Composite Tape Winding Process

    PubMed Central

    Yu, Tao; Kang, Chao; Zhao, Pan

    2018-01-01

    The composite tape winding process, which utilizes a tape winding machine and prepreg tapes, provides a promising way to improve the quality of composite products. Nevertheless, the process parameters of composite tape winding have crucial effects on the tensile strength and void content, which are closely related to the performances of the winding products. In this article, two different object values of winding products, including mechanical performance (tensile strength) and a physical property (void content), were respectively calculated. Thereafter, the paper presents an integrated methodology by combining multi-parameter relative sensitivity analysis and single-parameter sensitivity analysis to obtain the optimal intervals of the composite tape winding process. First, the global multi-parameter sensitivity analysis method was applied to investigate the sensitivity of each parameter in the tape winding processing. Then, the local single-parameter sensitivity analysis method was employed to calculate the sensitivity of a single parameter within the corresponding range. Finally, the stability and instability ranges of each parameter were distinguished. Meanwhile, the authors optimized the process parameter ranges and provided comprehensive optimized intervals of the winding parameters. The verification test validated that the optimized intervals of the process parameters were reliable and stable for winding products manufacturing. PMID:29385048

  1. Quality changes of pasteurised orange juice during storage: A kinetic study of specific parameters and their relation to colour instability.

    PubMed

    Wibowo, Scheling; Grauwet, Tara; Santiago, Jihan Santanina; Tomic, Jovana; Vervoort, Liesbeth; Hendrickx, Marc; Van Loey, Ann

    2015-11-15

    In view of understanding colour instability of pasteurised orange juice during storage, to the best of our knowledge, this study reports for the first time in a systematic and quantitative way on a range of changes in specific quality parameters as a function of time and as well as temperature (20-42 °C). A zero-order (°Brix, fructose, glucose), a first-order (vitamin C), a second-order (sucrose) and a fractional conversion model (oxygen) were selected to model the evolution of the parameters between parentheses. Activation energies ranged from 22 to 136 kJ mol(-1), HMF formation being the most temperature sensitive. High correlations were found between sugars, ascorbic acid, their degradation products (furfural and HMF) and total colour difference (ΔE(∗)). Based on PLS regression, the importance of the quality parameters for colour degradation was ranked relatively among each other: the acid-catalysed degradation of sugars and ascorbic acid degradation reactions appeared to be important for browning development in pasteurised orange juice during ambient storage. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Performance of ANFIS versus MLP-NN dissolved oxygen prediction models in water quality monitoring.

    PubMed

    Najah, A; El-Shafie, A; Karim, O A; El-Shafie, Amr H

    2014-02-01

    We discuss the accuracy and performance of the adaptive neuro-fuzzy inference system (ANFIS) in training and prediction of dissolved oxygen (DO) concentrations. The model was used to analyze historical data generated through continuous monitoring of water quality parameters at several stations on the Johor River to predict DO concentrations. Four water quality parameters were selected for ANFIS modeling, including temperature, pH, nitrate (NO3) concentration, and ammoniacal nitrogen concentration (NH3-NL). Sensitivity analysis was performed to evaluate the effects of the input parameters. The inputs with the greatest effect were those related to oxygen content (NO3) or oxygen demand (NH3-NL). Temperature was the parameter with the least effect, whereas pH provided the lowest contribution to the proposed model. To evaluate the performance of the model, three statistical indices were used: the coefficient of determination (R (2)), the mean absolute prediction error, and the correlation coefficient. The performance of the ANFIS model was compared with an artificial neural network model. The ANFIS model was capable of providing greater accuracy, particularly in the case of extreme events.

  3. Important technical parameters are not presented in reports of intraoral digital radiography in endodontic treatment: recommendations for future studies.

    PubMed

    Konishi, Masaru; Lindh, Christina; Nilsson, Mats; Tanimoto, Keiji; Rohlin, Madeleine

    2012-08-01

    The aims of this study were to review the literature on intraoral digital radiography in endodontic treatment with focus on technical parameters and to propose recommendations for improving the quality of reports in future publications. Two electronic databases were searched. Titles and abstracts were selected according to preestablished criteria. Data were extracted using a model of image acquisition and interpretation. The literature search yielded 233 titles and abstracts; 61 reports were read in full text. Recent reports presented technical parameters more thoroughly than older reports. Most reported important parameters for the x-ray unit, but for image interpretation only about one-half of the publications cited resolution of the display system and fewer than one-half bit depth of the graphics card. The methodologic quality of future publications must be improved to permit replication of studies and comparison of results between studies in dental digital radiography. Our recommendations can improve the quality of studies on diagnostic accuracy. Copyright © 2012 Mosby, Inc. All rights reserved.

  4. A water quality index model using stepwise regression and neural networks models for the Piabanha River basin in Rio de Janeiro, Brazil

    NASA Astrophysics Data System (ADS)

    Villas Boas, M. D.; Olivera, F.; Azevedo, J. S.

    2013-12-01

    The evaluation of water quality through 'indexes' is widely used in environmental sciences. There are a number of methods available for calculating water quality indexes (WQI), usually based on site-specific parameters. In Brazil, WQI were initially used in the 1970s and were adapted from the methodology developed in association with the National Science Foundation (Brown et al, 1970). Specifically, the WQI 'IQA/SCQA', developed by the Institute of Water Management of Minas Gerais (IGAM), is estimated based on nine parameters: Temperature Range, Biochemical Oxygen Demand, Fecal Coliforms, Nitrate, Phosphate, Turbidity, Dissolved Oxygen, pH and Electrical Conductivity. The goal of this study was to develop a model for calculating the IQA/SCQA, for the Piabanha River basin in the State of Rio de Janeiro (Brazil), using only the parameters measurable by a Multiparameter Water Quality Sonde (MWQS) available in the study area. These parameters are: Dissolved Oxygen, pH and Electrical Conductivity. The use of this model will allow to further the water quality monitoring network in the basin, without requiring significant increases of resources. The water quality measurement with MWQS is less expensive than the laboratory analysis required for the other parameters. The water quality data used in the study were obtained by the Geological Survey of Brazil in partnership with other public institutions (i.e. universities and environmental institutes) as part of the project "Integrated Studies in Experimental and Representative Watersheds". Two models were developed to correlate the values of the three measured parameters and the IQA/SCQA values calculated based on all nine parameters. The results were evaluated according to the following validation statistics: coefficient of determination (R2), Root Mean Square Error (RMSE), Akaike information criterion (AIC) and Final Prediction Error (FPE). The first model was a linear stepwise regression between three independent variables (input) and one dependent variable (output) to establish an equation relating input to output. This model produced the following statistics: R2 = 0.85, RMSE = 6.19, AIC =0.65 and FPE = 1.93. The second model was a Feedforward Neural Network with one tan-sigmoid hidden layer (4 neurons) and one linear output layer. The neural network was trained based on a backpropagation algorithm using the input as predictors and the output as target. The following statistics were found: R2 = 0.95, RMSE = 4.86, AIC= 0.33 and FPE = 1.39. The second model produced a better fit than the first one, having a greater R2 and smaller RMSE, AIC and FPE. The best performance of the second method can be attributed to the fact that the water quality parameters often exhibit nonlinear behaviors and neural networks are capable of representing nonlinear relationship efficiently, while the regression is limited to linear relationships. References: Brown, R.M., McLelland, N.I., Deininger, R.A., Tozer, R.G.1970. A Water Quality Index-Do we dare? Water & Sewage Works, October: 339-343.

  5. The case for regime-based water quality standards

    USGS Publications Warehouse

    Poole, Geoffrey C.; Dunham, J.B.; Keenan, D.M.; Sauter, S.T.; McCullough, D.A.; Mebane, Christopher; Lockwood, Jeffrey C.; Essig, Don A.; Hicks, Mark P.; Sturdevant, Debra J.; Materna, E.J.; Spalding, M.; Risley, John; Deppman, Marianne

    2004-01-01

    Conventional water quality standards have been successful in reducing the concentration of toxic substances in US waters. However, conventional standards are based on simple thresholds and are therefore poorly structured to address human-caused imbalances in dynamic, natural water quality parameters, such as nutrients, sediment, and temperature. A more applicable type of water quality standarda??a a??regime standarda??a??would describe desirable distributions of conditions over space and time within a stream network. By mandating the protection and restoration of the aquatic ecosystem dynamics that are required to support beneficial uses in streams, well-designed regime standards would facilitate more effective strategies for management of natural water quality parameters.

  6. High-volume image quality assessment systems: tuning performance with an interactive data visualization tool

    NASA Astrophysics Data System (ADS)

    Bresnahan, Patricia A.; Pukinskis, Madeleine; Wiggins, Michael

    1999-03-01

    Image quality assessment systems differ greatly with respect to the number and types of mags they need to evaluate, and their overall architectures. Managers of these systems, however, all need to be able to tune and evaluate system performance, requirements often overlooked or under-designed during project planning. Performance tuning tools allow users to define acceptable quality standards for image features and attributes by adjusting parameter settings. Performance analysis tools allow users to evaluate and/or predict how well a system performs in a given parameter state. While image assessment algorithms are becoming quite sophisticated, duplicating or surpassing the human decision making process in their speed and reliability, they often require a greater investment in 'training' or fine tuning of parameters in order to achieve optimum performance. This process may involve the analysis of hundreds or thousands of images, generating a large database of files and statistics that can be difficult to sort through and interpret. Compounding the difficulty is the fact that personnel charged with tuning and maintaining the production system may not have the statistical or analytical background required for the task. Meanwhile, hardware innovations have greatly increased the volume of images that can be handled in a given time frame, magnifying the consequences of running a production site with an inadequately tuned system. In this paper, some general requirements for a performance evaluation and tuning data visualization system are discussed. A custom engineered solution to the tuning and evaluation problem is then presented, developed within the context of a high volume image quality assessment, data entry, OCR, and image archival system. A key factor influencing the design of the system was the context-dependent definition of image quality, as perceived by a human interpreter. This led to the development of a five-level, hierarchical approach to image quality evaluation. Lower-level pass-fail conditions and decision rules were coded into the system. Higher-level image quality states were defined by allowing the users to interactively adjust the system's sensitivity to various image attributes by manipulating graphical controls. Results were presented in easily interpreted bar graphs. These graphs were mouse- sensitive, allowing the user to more fully explore the subsets of data indicated by various color blocks. In order to simplify the performance evaluation and tuning process, users could choose to view the results of (1) the existing system parameter state, (2) the results of any arbitrary parameter values they chose, or (3) the results of a quasi-optimum parameter state, derived by applying a decision rule to a large set of possible parameter states. Giving managers easy- to-use tools for defining the more subjective aspects of quality resulted in a system that responded to contextual cues that are difficult to hard-code. It had the additional advantage of allowing the definition of quality to evolve over time, as users became more knowledgeable as to the strengths and limitations of an automated quality inspection system.

  7. Long-term effects of melatonin on quality of life and sleep in haemodialysis patients (Melody study): a randomized controlled trial.

    PubMed

    Russcher, Marije; Koch, Birgit C P; Nagtegaal, J Elsbeth; van Ittersum, Frans J; Pasker-de Jong, Pieternel C M; Hagen, E Chris; van Dorp, Wim Th; Gabreëls, Bas; Wildbergh, Thierry X; van der Westerlaken, Monique M L; Gaillard, Carlo A J M; Ter Wee, Piet M

    2013-11-01

    The disturbed circadian rhythm in haemodialysis patients results in perturbed sleep. Short term melatonin supplementation has alleviated these sleep problems. Our aim was to investigate the effects of long-term melatonin supplementation on quality of life and sleep. In this randomized double-blind placebo-controlled trial haemodialysis patients suffering from subjective sleep problems received melatonin 3 mg day(-1) vs. placebo during 12 months. The primary endpoint quality of life parameter 'vitality' was measured with Medical Outcomes Study Short Form-36. Secondary outcomes were improvement of three sleep parameters measured by actigraphy and nighttime salivary melatonin concentrations. Sixty-seven patients were randomized. Forty-two patients completed the trial. With melatonin, no beneficial effect on vitality was seen. Other quality of life parameters showed both advantageous and disadvantageous effects of melatonin. Considering sleep, at 3 months sleep efficiency and actual sleep time had improved with melatonin compared with placebo on haemodialysis days (difference 7.6%, 95% CI 0.77, 14.4 and 49 min, 95% CI 2.1, 95.9, respectively). At 12 months none of the sleep parameters differed significantly from placebo. Melatonin salivary concentrations at 6 months had significantly increased in the melatonin group compared with the placebo group. The high drop-out rate limits the strength of our conclusions. However, although a previous study reported beneficial short term effects of melatonin on sleep in haemodialysis patients, in this long-term study the positive effects disappeared during follow up (6-12 months). Also the quality of life parameter, vitality, did not improve. Efforts should be made to elucidate the mechanism responsible for the loss of effect with chronic use. © 2013 The Authors. British Journal of Clinical Pharmacology © 2013 The British Pharmacological Society.

  8. Evaluation of ultrasound based sterilization approaches in terms of shelf life and quality parameters of fruit and vegetable juices.

    PubMed

    Khandpur, Paramjeet; Gogate, Parag R

    2016-03-01

    The present work evaluates the performance of ultrasound based sterilization approaches for processing of different fruit and vegetable juices in terms of microbial growth and changes in the quality parameters during the storage. Comparison with the conventional thermal processing has also been presented. A novel approach based on combination of ultrasound with ultraviolet irradiation and crude extract of essential oil from orange peels has been used for the first time. Identification of the microbial growth (total bacteria and yeast content) in the juices during the subsequent storage and assessing the safety for human consumption along with the changes in the quality parameters (Brix, titratable acidity, pH, ORP, salt, conductivity, TSS and TDS) has been investigated in details. The optimized ultrasound parameters for juice sterilization were established as ultrasound power of 100 W and treatment time of 15 min for the constant frequency operation (20 kHz). It has been established that more than 5 log reduction was achieved using the novel combined approaches based on ultrasound. The treated juices using different approaches based on ultrasound also showed lower microbial growth and improved quality characteristics as compared to the thermally processed juice. Scale up studies were also performed using spinach juice as the test sample with processing at 5 L volume for the first time. The ultrasound treated juice satisfied the microbiological and physiochemical safety limits in refrigerated storage conditions for 20 days for the large scale processing. Overall the present work conclusively established the usefulness of combined treatment approaches based on ultrasound for maintaining the microbiological safety of beverages with enhanced shelf life and excellent quality parameters as compared to the untreated and thermally processed juices. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. On Obtaining Estimates of the Fraction of Missing Information from Full Information Maximum Likelihood

    ERIC Educational Resources Information Center

    Savalei, Victoria; Rhemtulla, Mijke

    2012-01-01

    Fraction of missing information [lambda][subscript j] is a useful measure of the impact of missing data on the quality of estimation of a particular parameter. This measure can be computed for all parameters in the model, and it communicates the relative loss of efficiency in the estimation of a particular parameter due to missing data. It has…

  10. Global tilt and lumbar lordosis index: two parameters correlating with health-related quality of life scores-but how do they truly impact disability?

    PubMed

    Boissière, Louis; Takemoto, Mitsuru; Bourghli, Anouar; Vital, Jean-Marc; Pellisé, Ferran; Alanay, Ahmet; Yilgor, Caglar; Acaroglu, Emre; Perez-Grueso, Francisco Javier; Kleinstück, Frank; Obeid, Ibrahim

    2017-04-01

    Many radiological parameters have been reported to correlate with patient's disability including sagittal vertical axis (SVA), pelvic tilt (PT), and pelvic incidence minus lumbar lordosis (PI-LL). European literature reports other parameters such as lumbar lordosis index (LLI) and the global tilt (GT). If most parameters correlate with health-related quality of life scores (HRQLs), their impact on disability remains unclear. This study aimed to validate these parameters by investigating their correlation with HRQLs. It also aimed to evaluate the relationship between each of these sagittal parameters and HRQLs to fully understand the impact in adult spinal deformity management. A retrospective review of a multicenter, prospective database was carried out. The database inclusion criteria were adults (>18 years old) presenting any of the following radiographic parameters: scoliosis (Cobb ≥20°), SVA ≥5 cm, thoracic kyphosis ≥60° or PT ≥25°. All patients with complete data at baseline were included. Health-related quality of life scores, demographic variables (DVs), and radiographic parameters were collected at baseline. Differences in HRQLs among groups of each DV were assessed with analyses of variance. Correlations between radiographic variables and HRQLs were assessed using the Spearman rank correlation. Multivariate linear regression models were fitted for each of the HRQLs (Oswestry Disability Index [ODI], Scoliosis Research Society-22 subtotal score, or physical component summaries) with sagittal parameters and covariants as independent variables. A p<.05 value was considered statistically significant. Among a total of 755 included patients (mean age, 52.1 years), 431 were non-surgical candidates and 324 were surgical candidates. Global tilt and LLI significantly correlated with HRQLs (r=0.4 and -0.3, respectively) for univariate analysis. Demographic variables such as age, gender, body mass index, past surgery, and surgical or non-surgical candidate were significant predictors of ODI score. The likelihood ratio tests for the addition of the sagittal parameters showed that SVA, GT, T1 sagittal tilt, PI-LL, and LLI were statistically significant predictors for ODI score even adjusted for covariates. The differences of R 2 values from Model 1 were 1.5% at maximum, indicating that the addition of sagittal parameters to the reference model increased only 1.5% of the variance of ODI explained by the models. GT and LLI appear to be independent radiographic parameters impacting ODI variance. If most of the parameters described in the literature are correlated with ODI, the impact of these radiographic parameters is less than 2% of ODI variance, whereas 40% are explained by DVs. The importance of radiographic parameters lies more on their purpose to describe and understand the malalignment mechanisms than their univariate correlation with HRQLs. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. [Reorganizing the management of specialist uro-andrologic ultrasound health-care service: impact on professional quality].

    PubMed

    Dell'Atti, Lucio; Russo, Gian Rosario

    2011-01-01

    The process of organizing a ultrasound service nowadays can be improved by properly managing the user's request, the speed of response and safety, the standardization of methods and skills. The outpatients at our uro-andrologic ultrasound clinic (O.U. of Urology in Ferrara) received a questionnaire each; we administered a total of 640 questionnaires. The number of questionnaires collected was 532. Patients were asked to give an assessment of services using a qualitative method according to a 4-parameter response scale: very satisfied, satisfied, dissatisfied, very dissatisfied. The identification of indicators to be monitored by the user's perceived quality was accomplished by establishing the correlation coefficient between different parameters of analysis and an overall rating of the sample. Some of these parameters were: the relationship with the practitioner, the availability of doctors, the ability of doctors for reassurance, the completeness of information and facilities hygiene conditions. When these parameters vary, positively or negatively, also the citizen's overall opinion changes. The customer satisfaction is an important component of the quality of care, it represents both an indicator of the effectiveness of health intervention and the ability to meet quality requirements of the health service organization. The objective of an ultrasound service should be to provide, within a reasonable timeframe, the supply of high quality with qualified personnel, with adequate tools and procedures.

  12. Optimization of ciprofloxacin complex loaded PLGA nanoparticles for pulmonary treatment of cystic fibrosis infections: Design of experiments approach.

    PubMed

    Günday Türeli, Nazende; Türeli, Akif Emre; Schneider, Marc

    2016-12-30

    Design of Experiments (DoE) is a powerful tool for systematic evaluation of process parameters' effect on nanoparticle (NP) quality with minimum number of experiments. DoE was employed for optimization of ciprofloxacin loaded PLGA NPs for pulmonary delivery against Pseudomonas aeruginosa infections in cystic fibrosis (CF) lungs. Since the biofilm produced by bacteria was shown to be a complicated 3D barrier with heterogeneous meshes ranging from 100nm to 500nm, nanoformulations small enough to travel through those channels were assigned as target quality. Nanoprecipitation was realized utilizing MicroJet Reactor (MJR) technology based on impinging jets principle. Effect of MJR parameters flow rate, temperature and gas pressure on particle size and PDI was investigated using Box-Behnken design. The relationship between process parameters and particle quality was demonstrated by constructed fit functions (R 2 =0.9934 p<0.0001 and R 2 =0.9983 p<0.0001, for particle size and PDI, respectively). Prepared nanoformulations varied between 145.2 and 979.8nm with PDI ranging from 0.050 to 1.00 and showed encapsulation efficiencies >65%. Response surface plots provided experimental data-based understanding of MJR parameters' effect, thus NP quality. Presented work enables ciprofloxacin loaded PLGA nanoparticle preparations with pre-defined quality to fulfill the requirements of local drug delivery under CF disease conditions. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Water and sediment quality parameters in the Chalan Beel, the largest wetland of Bangladesh

    NASA Astrophysics Data System (ADS)

    Sayeed, Md. Abu; Hossain, Mostafa Ali Reza; Wahab, Md. Abdul; Hasan, Md. Tawheed; Simon, Kumar Das; Mazumder, Sabuj Kanti

    2015-07-01

    A study was conducted to investigate the status of the water and sediment quality in the Chalan Beel-a major fresh water fish reservoir of the country for a period of one year from July 2007 to June 2008. The mean values of water quality parameters (depth: 214.73±152.22 cm, temperature 27.68±4.26°C, transparency 123±82 cm, pH 9.7±0.47, total alkalinity 137±42 mg/L, conductivity 307±147 μs/cm, total dissolved solids 183±89 mg/L, ammonia-N 0.27±0.39 mg/L, nitrate-N 0.09±0.07 mg/L, phosphate-P 2.01±2.53 mg/L) and sediment quality parameters (pH 7.21±0.35, organic matter 2.59±0.52%, total nitrogen 0.09±0.04%, available phosphorus 5.4±3.6 Meq./100 g and exchangeable potassium 0.43±0.14 Meq./100 g) were within the range recommended for most of the inland fishes of Bangladesh. Although the water and sediment quality parameters except ammonia and phosphate are in the suitable range, the overall results suggest that better management techniques should be practiced in order to overcome the declining trend of associated aquatic life (fauna and flora) of this important fresh water body of Bangladesh.

  14. Effect of intense short rainfall events on coastal water quality parameters from remote sensing data

    NASA Astrophysics Data System (ADS)

    Corbari, Chiara; Lassini, Fabio; Mancini, Marco

    2016-07-01

    Strong rainfall events, especially during summer, in small river basins cause spills in the sea that often compromise the quality of coastal waters. The goal of this paper is then to study the changes of coastal waters quality as a result of intense rainfall events during the bathing season through the use of remote sensing data. These analyses are performed at the outlets of small watersheds which are not usually affected by high sediment transport as in the case of large basins which are persistently affected by intense solid transport which does not allow retrieving a reliable correlation between rainfall events and water quality parameters. Four small watersheds in different Italian regions on the Mediterranean Sea are selected for this study. The remotely sensed parameters of turbidity, total suspend solids and secchi disk depth, are retrieved from MODIS data. Secchi disk depths are also compared to available ground data during the summer seasons between 2003 and 2006 showing good correlations. Then the spatial and temporal changes of these parameters are analyzed after intense short storm events. Increases of turbidity and total suspend solids are found to be around 35 NTU and 20 mg L-1 respectively depending on the intensity of the rainfall event and on the distance from the shoreline. Moreover the recovery of water quality after the rain event is reached after two or three days.

  15. National Survey on Internal Quality Control Practice for Lipid Parameters in Laboratories of China from 2014 to 2016.

    PubMed

    Ye, Yuanyuan; Wang, Wei; Zhao, Haijian; He, Falin; Zhong, Kun; Yuan, Shuai; Wang, Zhiguo

    2017-09-01

    To investigate the situation of Internal Quality Control (IQC) practice for total cholesterol, triglycerides, HDL-cholesterol and LDL-cholesterol from 2014 to 2016 in laboratories in China and provide improvement measurements. A web-based External Quality Assessment (EQA) system was used to collect IQC data of lipid parameters in laboratories which continuously participated in the national EQA programs in China from 2014 to 2016. Pass rate of the coefficients of variation (CVs) of two level quality controls in four lipid parameters were calculated according to six quality specifications for precision to evaluate the current status of precision level of the four lipid parameters and their change over time in China. 533, 512, 504, and 466 laboratories continuously reported the data of level one for total cholesterol, triglyceride, HDL-cholesterol and LDL-cholesterol, and 212, 210, 208 and 198 laboratories reported the level two, respectively. The percentage of laboratories meeting the quality specification varied based on different criteria. Non-significant change can be found in the pass rate of CVs over time. The number of laboratories using a closed system increased over time, but still only accounted for a small proportion. There is no significant difference in the pass rate of CVs between closed and open systems. Triglycerides currently have a fairly good performance in China. While the performance of laboratories on total cholesterol, HDL-cholesterol and LDL-cholesterol has yet to be improved.

  16. Characterisation of dissolved organic matter in stormwater using high-performance size exclusion chromatography.

    PubMed

    Huang, Huiping; Chow, Christopher W K; Jin, Bo

    2016-04-01

    Understanding the complexity of dissolved organic matter (DOM) in stormwater has drawn a lot of interest, since DOM from stormwater causes not only environmental impacts, but also worsens downstream aquatic quality associated with water supply and treatability. This study introduced and employed high-performance size exclusion chromatography (HPSEC) coupled with an ultraviolet-visible (UV-vis) diode array detector to assess changes in stormwater-associated DOM characteristics. Stormwater DOM was also analysed in relation to storm event characteristics, water quality and spectroscopic analysis. Statistical tools were used to determine the correlations within DOM and water quality measurements. Results showed that dissolved organic carbon (DOC) and UV absorbance at 254 nm (UV254) as conventional DOM parameters were found to be correlated well to the changes in stormwater quality during each of the three storm events studied. Both detector wavelengths (210 and 254 nm) and their ratio (A210/A254) were found to provide additional information on the physiochemical properties of stormwater-associated DOM. This study indicated that A210/A254 is an important parameter which could be used to estimate the DOM proportions of functional groups and conjugated carbon species. This study provided also an understanding of stormwater quality constituents through assessing variability and sensitivity for various parameters, and the additional information of rainfall characteristics on runoff quality data for a better understanding of parameter correlations and influences. Copyright © 2015. Published by Elsevier B.V.

  17. [Effects of land use structure on water quality in Xin'anjiang River].

    PubMed

    Cao, Fang-Fang; Li, Xue; Wang, Dong; Zhao, Yue; Wang, Yu-Qiu

    2013-07-01

    Take Xin'anjiang upstream watershed as a case study. Based on data of interpreting TM orthophoto images and water quality monitoring in May 2010, the land use map of Xin'anjiang River, which was categorized to cultivated land, forestland, grassland, water body, building site, was obtained. Using ArcGIS hydrological and spatial analysis function, Xin'anjiang River was divided into eight sub-watersheds, and its watershed land use structure was analyzed. The water quality parameters such as TN, TP, permanganate index, fecal coliform bacteria were monitored from Jan 2010 to Dec 2010. The relations between water quality and land use were analyzed. The results showed that TN and NH4(+) -N had a significant temporal variation: dry season > wet season > normal river flow period, but other parameters did not vary significantly. In the space, Yuliang and Pukou were the most serious pollution sites. Cultivated land, water body, building site had a positive impact on water quality parameters, while there were negative correlation between the forestland and grassland. Annually, cultivated land had the most significantly important effect on TN, NH4(+) -N and permanganate index, and grassland had the most significantly important effect on TP. Cultivated land had the most prominently important impact on water quality parameters in dry season and wet season. What's more, in the normal river flow, cultivated land, grassland and forestland had the most remarkably important influence on TN, TP and fecal coliform bacteria respectively.

  18. Nimbus-7 Scanning Multichannel Microwave Radiometer (SMMR) PARM tape user's guide

    NASA Technical Reports Server (NTRS)

    Han, D.; Gloersen, P.; Kim, S. T.; Fu, C. C.; Cebula, R. P.; Macmillan, D.

    1992-01-01

    The Scanning Multichannel Microwave Radiometer (SMMR) instrument, onboard the Nimbus-7 spacecraft, collected data from Oct. 1978 until Jun. 1986. The data were processed to physical parameter level products. Geophysical parameters retrieved include the following: sea-surface temperatures, sea-surface windspeed, total column water vapor, and sea-ice parameters. These products are stored on PARM-LO, PARM-SS, and PARM-30 tapes. The geophysical parameter retrieval algorithms and the quality of these products are described for the period between Nov. 1978 and Oct 1985. Additionally, data formats and data availability are included.

  19. Quality of remote sensing measurements of cloud physical parameters in the cooperative convective precipitation experiment

    NASA Technical Reports Server (NTRS)

    Wu, M.-L.

    1985-01-01

    In order to develop the remote sensing techniques to infer cloud physical parameters, a multispectral cloud radiometer (MCR) was mounted on a NASA high-altitude aircraft in conjunction with the Cooperative Convective Precipitation Experiment in 1981. The MCR has seven spectral channels, of which three are centered near windows associated with water vapor bands in the near infrared, two are centered near the oxygen A band at 0.76 microns, one is centered at the 1.14-micron water vapor band, and one is centered in the thermal infrared. The reflectance and temperature measured on May 31, 1981, are presented together with theoretical calculations. The results indicate that the MCR produces quality measurements. Therefore several cloud parameters can be derived with good accuracy. The parameters are the cloud-scaled optical thickness, cloud top pressure, volume scattering coefficient, particle thermodynamic phase, effective mean particle size, and cloud-top temperature.

  20. Measurement and analysis of thrust force in drilling sisal-glass fiber reinforced polymer composites

    NASA Astrophysics Data System (ADS)

    Ramesh, M.; Gopinath, A.

    2017-05-01

    Drilling of composite materials is difficult when compared to the conventional materials because of its in-homogeneous nature. The force developed during drilling play a major role in the surface quality of the hole and minimizing the damages around the surface. This paper focuses the effect of drilling parameters on thrust force in drilling of sisal-glass fiber reinforced polymer composite laminates. The quadratic response models are developed by using response surface methodology (RSM) to predict the influence of cutting parameters on thrust force. The adequacy of the models is checked by using the analysis of variance (ANOVA). A scanning electron microscope (SEM) analysis is carried out to analyze the quality of the drilled surface. From the results, it is found that, the feed rate is the most influencing parameter followed by spindle speed and the drill diameter is the least influencing parameter on the thrust force.

  1. Method for determining formation quality factor from well log data and its application to seismic reservoir characterization

    DOEpatents

    Walls, Joel; Taner, M. Turhan; Dvorkin, Jack

    2006-08-08

    A method for seismic characterization of subsurface Earth formations includes determining at least one of compressional velocity and shear velocity, and determining reservoir parameters of subsurface Earth formations, at least including density, from data obtained from a wellbore penetrating the formations. A quality factor for the subsurface formations is calculated from the velocity, the density and the water saturation. A synthetic seismogram is calculated from the calculated quality factor and from the velocity and density. The synthetic seismogram is compared to a seismic survey made in the vicinity of the wellbore. At least one parameter is adjusted. The synthetic seismogram is recalculated using the adjusted parameter, and the adjusting, recalculating and comparing are repeated until a difference between the synthetic seismogram and the seismic survey falls below a selected threshold.

  2. Effect of Pulse Parameters on Weld Quality in Pulsed Gas Metal Arc Welding: A Review

    NASA Astrophysics Data System (ADS)

    Pal, Kamal; Pal, Surjya K.

    2011-08-01

    The weld quality comprises bead geometry and its microstructure, which influence the mechanical properties of the weld. The coarse-grained weld microstructure, higher heat-affected zone, and lower penetration together with higher reinforcement reduce the weld service life in continuous mode gas metal arc welding (GMAW). Pulsed GMAW (P-GMAW) is an alternative method providing a better way for overcoming these afore mentioned problems. It uses a higher peak current to allow one molten droplet per pulse, and a lower background current to maintain the arc stability. Current pulsing refines the grains in weld fusion zone with increasing depth of penetration due to arc oscillations. Optimum weld joint characteristics can be achieved by controlling the pulse parameters. The process is versatile and easily automated. This brief review illustrates the effect of pulse parameters on weld quality.

  3. Modelling of 10 Gbps Free Space Optics Communication Link Using Array of Receivers in Moderate and Harsh Weather Conditions

    NASA Astrophysics Data System (ADS)

    Gupta, Amit; Shaina, Nagpal

    2017-08-01

    Intersymbol interference and attenuation of signal are two major parameters affecting the quality of transmission in Free Space Optical (FSO) Communication link. In this paper, the impact of these parameters on FSO communication link is analysed for delivering high-quality data transmission. The performance of the link is investigated under the influence of amplifier in the link. The performance parameters of the link like minimum bit error rate, received signal power and Quality factor are examined by employing erbium-doped fibre amplifier in the link. The effects of amplifier are visualized with the amount of received power. Further, the link is simulated for moderate weather conditions at various attenuation levels on transmitted signal. Finally, the designed link is analysed in adverse weather conditions by using high-power laser source for optimum performance.

  4. Economical analysis of saturation mutagenesis experiments

    PubMed Central

    Acevedo-Rocha, Carlos G.; Reetz, Manfred T.; Nov, Yuval

    2015-01-01

    Saturation mutagenesis is a powerful technique for engineering proteins, metabolic pathways and genomes. In spite of its numerous applications, creating high-quality saturation mutagenesis libraries remains a challenge, as various experimental parameters influence in a complex manner the resulting diversity. We explore from the economical perspective various aspects of saturation mutagenesis library preparation: We introduce a cheaper and faster control for assessing library quality based on liquid media; analyze the role of primer purity and supplier in libraries with and without redundancy; compare library quality, yield, randomization efficiency, and annealing bias using traditional and emergent randomization schemes based on mixtures of mutagenic primers; and establish a methodology for choosing the most cost-effective randomization scheme given the screening costs and other experimental parameters. We show that by carefully considering these parameters, laboratory expenses can be significantly reduced. PMID:26190439

  5. Grey Relational Analysis Coupled with Principal Component Analysis for Optimization of Stereolithography Process to Enhance Part Quality

    NASA Astrophysics Data System (ADS)

    Raju, B. S.; Sekhar, U. Chandra; Drakshayani, D. N.

    2017-08-01

    The paper investigates optimization of stereolithography process for SL5530 epoxy resin material to enhance part quality. The major characteristics indexed for performance selected to evaluate the processes are tensile strength, Flexural strength, Impact strength and Density analysis and corresponding process parameters are Layer thickness, Orientation and Hatch spacing. In this study, the process is intrinsically with multiple parameters tuning so that grey relational analysis which uses grey relational grade as performance index is specially adopted to determine the optimal combination of process parameters. Moreover, the principal component analysis is applied to evaluate the weighting values corresponding to various performance characteristics so that their relative importance can be properly and objectively desired. The results of confirmation experiments reveal that grey relational analysis coupled with principal component analysis can effectively acquire the optimal combination of process parameters. Hence, this confirm that the proposed approach in this study can be an useful tool to improve the process parameters in stereolithography process, which is very useful information for machine designers as well as RP machine users.

  6. Sound quality characteristics of refrigerator noise in real living environments with relation to psychoacoustical and autocorrelation function parameters.

    PubMed

    Sato, Shin-ichi; You, Jin; Jeon, Jin Yong

    2007-07-01

    Psychoacoustical and autocorrelation function (ACF) parameters were employed to describe the temporal fluctuations of refrigerator noise during starting, transition into/from the stationary phase and termination of operation. The temporal fluctuations of refrigerator noise include a click at start-up, followed by a rapid increase in volume, a change of pitch, and termination of the operation. Subjective evaluations of the noise of 24 different refrigerators were conducted in a real living environment. The relationship between objective measures and perceived noisiness was examined by multiple regression analysis. Sound quality indices were developed based on psychoacoustical and ACF parameters. The psychoacoustical parameters found to be important for evaluating noisiness in the stationary phase were loudness and roughness. The relationship between noisiness and ACF parameters shows that sound energy and its fluctuations are important for evaluating noisiness. Also, refrigerator sounds that had a fluctuation of pitch were rated as more annoying. The tolerance level for the starting phase of refrigerator noise was found to be 33 dBA, which is the level where 65% of the participants in the subjective tests were satisfied.

  7. Characterization and durability testing of plasma-sprayed zirconia-yttria and hafnia-yttria thermal barrier coatings. Part 2: Effect of spray parameters on the performance of several hafnia-yttria and zirconia-yttria coatings

    NASA Technical Reports Server (NTRS)

    Miller, Robert A.; Leissler, George W.

    1993-01-01

    This is the second of two reports which discuss initial experiments on thermal barrier coatings prepared and tested in newly upgraded plasma spray and burner rig test facilities at LeRC. The first report, part 1, describes experiments designed to establish the spray parameters for the baseline zirconia-yttria coating. Coating quality was judged primarily by the response to burner rig exposure, together with a variety of other characterization approaches including thermal diffusivity measurements. That portion of the study showed that the performance of the baseline NASA coating was not strongly sensitive to processing parameters. In this second part of the study, new hafnia-yttria coatings were evaluated with respect to both baseline and alternate zirconia-yttria coatings. The hafnia-yttria and the alternate zirconia-yttria coatings were very sensitive to plasma-spray parameters in that high-quality coatings were obtained only when specific parameters were used. The reasons for this important observation are not understood.

  8. Parameter estimation methods for gene circuit modeling from time-series mRNA data: a comparative study.

    PubMed

    Fan, Ming; Kuwahara, Hiroyuki; Wang, Xiaolei; Wang, Suojin; Gao, Xin

    2015-11-01

    Parameter estimation is a challenging computational problem in the reverse engineering of biological systems. Because advances in biotechnology have facilitated wide availability of time-series gene expression data, systematic parameter estimation of gene circuit models from such time-series mRNA data has become an important method for quantitatively dissecting the regulation of gene expression. By focusing on the modeling of gene circuits, we examine here the performance of three types of state-of-the-art parameter estimation methods: population-based methods, online methods and model-decomposition-based methods. Our results show that certain population-based methods are able to generate high-quality parameter solutions. The performance of these methods, however, is heavily dependent on the size of the parameter search space, and their computational requirements substantially increase as the size of the search space increases. In comparison, online methods and model decomposition-based methods are computationally faster alternatives and are less dependent on the size of the search space. Among other things, our results show that a hybrid approach that augments computationally fast methods with local search as a subsequent refinement procedure can substantially increase the quality of their parameter estimates to the level on par with the best solution obtained from the population-based methods while maintaining high computational speed. These suggest that such hybrid methods can be a promising alternative to the more commonly used population-based methods for parameter estimation of gene circuit models when limited prior knowledge about the underlying regulatory mechanisms makes the size of the parameter search space vastly large. © The Author 2015. Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.

  9. Testing item response theory invariance of the standardized Quality-of-life Disease Impact Scale (QDIS(®)) in acute coronary syndrome patients: differential functioning of items and test.

    PubMed

    Deng, Nina; Anatchkova, Milena D; Waring, Molly E; Han, Kyung T; Ware, John E

    2015-08-01

    The Quality-of-life (QOL) Disease Impact Scale (QDIS(®)) standardizes the content and scoring of QOL impact attributed to different diseases using item response theory (IRT). This study examined the IRT invariance of the QDIS-standardized IRT parameters in an independent sample. The differential functioning of items and test (DFIT) of a static short-form (QDIS-7) was examined across two independent sources: patients hospitalized for acute coronary syndrome (ACS) in the TRACE-CORE study (N = 1,544) and chronically ill US adults in the QDIS standardization sample. "ACS-specific" IRT item parameters were calibrated and linearly transformed to compare to "standardized" IRT item parameters. Differences in IRT model-expected item, scale and theta scores were examined. The DFIT results were also compared in a standard logistic regression differential item functioning analysis. Item parameters estimated in the ACS sample showed lower discrimination parameters than the standardized discrimination parameters, but only small differences were found for thresholds parameters. In DFIT, results on the non-compensatory differential item functioning index (range 0.005-0.074) were all below the threshold of 0.096. Item differences were further canceled out at the scale level. IRT-based theta scores for ACS patients using standardized and ACS-specific item parameters were highly correlated (r = 0.995, root-mean-square difference = 0.09). Using standardized item parameters, ACS patients scored one-half standard deviation higher (indicating greater QOL impact) compared to chronically ill adults in the standardization sample. The study showed sufficient IRT invariance to warrant the use of standardized IRT scoring of QDIS-7 for studies comparing the QOL impact attributed to acute coronary disease and other chronic conditions.

  10. Sperm quality biomarkers complement reproductive and endocrine parameters in investigating environmental contaminants in common carp (Cyprinus carpio) from the Lake Mead National Recreation Area

    USGS Publications Warehouse

    Jenkins, Jill A.; Rosen, Michael R.; Dale, Rassa O.; Echols, Kathy R.; Torres, Leticia; Wieser, Carla M.; Kersten, Constance A.; Goodbred, Steven L.

    2018-01-01

    Lake Mead National Recreational Area (LMNRA) serves as critical habitat for several federally listed species and supplies water for municipal, domestic, and agricultural use in the Southwestern U.S. Contaminant sources and concentrations vary among the sub-basins within LMNRA. To investigate whether exposure to environmental contaminants is associated with alterations in male common carp (Cyprinus carpio) gamete quality and endocrine- and reproductive parameters, data were collected among sub-basins over 7 years (1999–2006). Endpoints included sperm quality parameters of motility, viability, mitochondrial membrane potential, count, morphology, and DNA fragmentation; plasma components were vitellogenin (VTG), 17ß-estradiol, 11-keto-testosterone, triiodothyronine, and thyroxine. Fish condition factor, gonadosomatic index, and gonadal histology parameters were also measured. Diminished biomarker effects were noted in 2006, and sub-basin differences were indicated by the irregular occurrences of contaminants and by several associations between chemicals (e.g., polychlorinated biphenyls, hexachlorobenzene, galaxolide, and methyl triclosan) and biomarkers (e.g., plasma thyroxine, sperm motility and DNA fragmentation). By 2006, sex steroid hormone and VTG levels decreased with subsequent reduced endocrine disrupting effects. The sperm quality bioassays developed and applied with carp complemented endocrine and reproductive data, and can be adapted for use with other species.

  11. Parasympathetic reinnervation accompanied by improved post-exercise heart rate recovery and quality of life in heart transplant recipients.

    PubMed

    Imamura, Teruhiko; Kinugawa, Koichiro; Okada, Ikuko; Kato, Naoko; Fujino, Takeo; Inaba, Toshiro; Maki, Hisataka; Hatano, Masaru; Kinoshita, Osamu; Nawata, Kan; Kyo, Shunei; Ono, Minoru

    2015-01-01

    Although sympathetic reinnervation is accompanied by the improvement of exercise tolerability during the first years after heart transplantation (HTx), little is known about parasympathetic reinnervation and its clinical impact. We enrolled 21 recipients (40 ± 16 years, 71% male) who had received successive cardiopulmonary exercise testing at 6 months, and 1 and 2 years after HTx. Exercise parameters such as peak oxygen consumption or achieved maximum load remained unchanged, whereas recovery parameters including heart rate (HR) recovery during 2 minutes and the delay of peak HR, which are influenced by parasympathetic activity, improved significantly during post-HTx 2 years (P < 0.05 for both). HR variability was analysed at post-HTx 6 months in 18 recipients, and high frequency power, representing parasympathetic activity, was significantly associated with the 2 recovery parameters (P < 0.05 for all). We also assessed quality of life using the Minnesota Living with Heart Failure (HF) Questionnaire at post-HTx 6 months and 2 years in the same 18 recipients, and those with improved recovery parameters enjoyed a better HF-specific quality of life (P < 0.05 for both). In conclusion, parasympathetic reinnervation emerges along with improved post-exercise recovery ability of HR and quality of life during post-HTx 2 years.

  12. Sperm quality biomarkers complement reproductive and endocrine parameters in investigating environmental contaminants in common carp (Cyprinus carpio) from the Lake Mead National Recreation Area.

    PubMed

    Jenkins, Jill A; Rosen, Michael R; Draugelis-Dale, Rassa O; Echols, Kathy R; Torres, Leticia; Wieser, Carla M; Kersten, Constance A; Goodbred, Steven L

    2018-05-01

    Lake Mead National Recreational Area (LMNRA) serves as critical habitat for several federally listed species and supplies water for municipal, domestic, and agricultural use in the Southwestern U.S. Contaminant sources and concentrations vary among the sub-basins within LMNRA. To investigate whether exposure to environmental contaminants is associated with alterations in male common carp (Cyprinus carpio) gamete quality and endocrine- and reproductive parameters, data were collected among sub-basins over 7 years (1999-2006). Endpoints included sperm quality parameters of motility, viability, mitochondrial membrane potential, count, morphology, and DNA fragmentation; plasma components were vitellogenin (VTG), 17ß-estradiol, 11-keto-testosterone, triiodothyronine, and thyroxine. Fish condition factor, gonadosomatic index, and gonadal histology parameters were also measured. Diminished biomarker effects were noted in 2006, and sub-basin differences were indicated by the irregular occurrences of contaminants and by several associations between chemicals (e.g., polychlorinated biphenyls, hexachlorobenzene, galaxolide, and methyl triclosan) and biomarkers (e.g., plasma thyroxine, sperm motility and DNA fragmentation). By 2006, sex steroid hormone and VTG levels decreased with subsequent reduced endocrine disrupting effects. The sperm quality bioassays developed and applied with carp complemented endocrine and reproductive data, and can be adapted for use with other species. Published by Elsevier Inc.

  13. [Weight parameters of water quality impact and risk grade determination of water environmental sensitive spots in Jiashan].

    PubMed

    Xie, Rong-Rong; Pang, Yong; Zhang, Qian; Chen, Ke; Sun, Ming-Yuan

    2012-07-01

    For the safety of the water environment in Jiashan county in Zhejiang Province, one-dimensional hydrodynamic and water quality models are established based on three large-scale monitoring of hydrology and water quality in Jiashan county, three water environmental sensitive spots including Hongqitang dam Chijia hydrological station and Luxie pond are selected to investigate weight parameters of water quality impact and risk grade determination. Results indicate as follows (1) Internal pollution impact in Jiashan areas was greater than the external, the average weight parameters of internal chemical oxygen demand (COD) pollution is 55.3%, internal ammonia nitrogen (NH(4+)-N) is 67.4%, internal total phosphor (TP) is 63.1%. Non-point pollution impact in Jiashan areas was greater than point pollution impact, the average weight parameters of non-point COD pollutions is 53.7%, non-point NH(4+)-N is 65.9%, non-point TP is 57.8%. (2) The risk of Hongqitang dam and Chijia hydrological station are in the middle risk. The risk of Luxie pond is also in the middle risk in August, and in April and December the risk of Luxie pond is low. The strategic decision will be suggested to guarantee water environment security and social and economic security in the study.

  14. Assessing the combined effects of urbanisation and climate change on the river water quality in an integrated urban wastewater system in the UK.

    PubMed

    Astaraie-Imani, Maryam; Kapelan, Zoran; Fu, Guangtao; Butler, David

    2012-12-15

    Climate change and urbanisation are key factors affecting the future of water quality and quantity in urbanised catchments and are associated with significant uncertainty. The work reported in this paper is an evaluation of the combined and relative impacts of climate change and urbanisation on the receiving water quality in the context of an Integrated Urban Wastewater System (IUWS) in the UK. The impacts of intervening system operational control parameters are also investigated. Impact is determined by a detailed modelling study using both local and global sensitivity analysis methods together with correlation analysis. The results obtained from the case-study analysed clearly demonstrate that climate change combined with increasing urbanisation is likely to lead to worsening river water quality in terms of both frequency and magnitude of breaching threshold dissolved oxygen and ammonium concentrations. The results obtained also reveal the key climate change and urbanisation parameters that have the largest negative impact as well as the most responsive IUWS operational control parameters including major dependencies between all these parameters. This information can be further utilised to adapt future IUWS operation and/or design which, in turn, should make these systems more resilient to future climate and urbanisation changes. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Simultaneous evaluation of superoxide content and mitochondrial membrane potential in stallion semen samples provides additional information about sperm quality.

    PubMed

    Johannisson, A; Figueiredo, M I; Al-Kass, Z; Morrell, J M

    2018-05-01

    An improved fertility prediction for stallions is of importance for equine breeding. Here, we investigate the potential of a combined staining of stallion spermatozoa for superoxide and mitochondrial membrane potential (MMP) for this purpose. Semen samples were analysed immediately after arrival at the laboratory, as well as after 24 h. Superoxide was measured by MitoSOXRed, while MMP was measured with JC-1. Menadione was used to stimulate superoxide production. In addition, other parameters of sperm quality, namely motility, membrane integrity, chromatin integrity, sperm kinematics and Hoechst 33258 exclusion were measured and correlated to superoxide production and MMP. Both bivariate correlations between measured parameters as well as multivariate analysis were performed. Measured values in the superoxide/MMP assay did not correlate with other parameters. However, there was a strong negative correlation (r = 0.96 after 0 h, r = 0.95 after 24 h) between membrane integrity and chromatin integrity. Moderate positive correlations were found between motility parameters and membrane integrity, as well as moderate negative correlations between motility parameters and chromatin integrity. The multivariate analysis revealed that membrane integrity, chromatin integrity and motility contributed to the first principal component, while the second was influenced by superoxide/MMP parameters as well as sperm kinematics. Storage of samples for 24 h decreased motility, chromatin integrity and membrane integrity. In conclusion, combined measurement of superoxide and MMP provides additional information not obtained by other assays of sperm quality. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Global parameter estimation for thermodynamic models of transcriptional regulation.

    PubMed

    Suleimenov, Yerzhan; Ay, Ahmet; Samee, Md Abul Hassan; Dresch, Jacqueline M; Sinha, Saurabh; Arnosti, David N

    2013-07-15

    Deciphering the mechanisms involved in gene regulation holds the key to understanding the control of central biological processes, including human disease, population variation, and the evolution of morphological innovations. New experimental techniques including whole genome sequencing and transcriptome analysis have enabled comprehensive modeling approaches to study gene regulation. In many cases, it is useful to be able to assign biological significance to the inferred model parameters, but such interpretation should take into account features that affect these parameters, including model construction and sensitivity, the type of fitness calculation, and the effectiveness of parameter estimation. This last point is often neglected, as estimation methods are often selected for historical reasons or for computational ease. Here, we compare the performance of two parameter estimation techniques broadly representative of local and global approaches, namely, a quasi-Newton/Nelder-Mead simplex (QN/NMS) method and a covariance matrix adaptation-evolutionary strategy (CMA-ES) method. The estimation methods were applied to a set of thermodynamic models of gene transcription applied to regulatory elements active in the Drosophila embryo. Measuring overall fit, the global CMA-ES method performed significantly better than the local QN/NMS method on high quality data sets, but this difference was negligible on lower quality data sets with increased noise or on data sets simplified by stringent thresholding. Our results suggest that the choice of parameter estimation technique for evaluation of gene expression models depends both on quality of data, the nature of the models [again, remains to be established] and the aims of the modeling effort. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. Vineyard zonal management for grape quality assessment by combining airborne remote sensed imagery and soil sensors

    NASA Astrophysics Data System (ADS)

    Bonilla, I.; Martínez De Toda, F.; Martínez-Casasnovas, J. A.

    2014-10-01

    Vineyard variability within the fields is well known by grape growers, producing different plant responses and fruit characteristics. Many technologies have been developed in last recent decades in order to assess this spatial variability, including remote sensing and soil sensors. In this paper we study the possibility of creating a stable classification system that better provides useful information for the grower, especially in terms of grape batch quality sorting. The work was carried out during 4 years in a rain-fed Tempranillo vineyard located in Rioja (Spain). NDVI was extracted from airborne imagery, and soil conductivity (EC) data was acquired by an EM38 sensor. Fifty-four vines were sampled at véraison for vegetative parameters and before harvest for yield and grape analysis. An Isocluster unsupervised classification in two classes was performed in 5 different ways, combining NDVI maps individually, collectively and combined with EC. The target vines were assigned in different zones depending on the clustering combination. Analysis of variance was performed in order to verify the ability of the combinations to provide the most accurate information. All combinations showed a similar behaviour concerning vegetative parameters. Yield parameters classify better by the EC-based clustering, whilst maturity grape parameters seemed to give more accuracy by combining all NDVIs and EC. Quality grape parameters (anthocyanins and phenolics), presented similar results for all combinations except for the NDVI map of the individual year, where the results were poorer. This results reveal that stable parameters (EC or/and NDVI all-together) clustering outcomes in better information for a vineyard zonal management strategy.

  18. Comparative analysis of effluent water quality from a municipal treatment plant and two on-site wastewater treatment systems.

    PubMed

    Garcia, Santos N; Clubbs, Rebekah L; Stanley, Jacob K; Scheffe, Brian; Yelderman, Joe C; Brooks, Bryan W

    2013-06-01

    Though decentralized on-site technologies are extensively employed for wastewater treatment around the globe, an understanding of effluent water quality impairments associated with these systems remain less understood than effluent discharges from centralized municipal wastewater treatment facilities. Using a unique experimental facility, a novel comparative analysis of effluent water quality was performed from model decentralized aerobic (ATS) and septic (STS) on-site wastewater treatment systems and a centralized municipal wastewater treatment plant (MTP). The ATS and STS units did not benefit from further soil treatment. Each system received common influent wastewater from the Waco, Texas, USA Metropolitan Area Regional Sewerage System. We tested the hypothesis that MTP effluent would exhibit higher water quality than on-site effluents, based on parameters selected for study. A tiered testing approach was employed to assess the three effluent discharges: select routine water quality parameters (Tier I), whole effluent toxicity (Tier II), and select endocrine-active compounds (Tier III). Contrary to our hypothesis, ATS effluent was not statistically different from MTP effluents, based on Tier I and III parameters, but reproductive responses of Daphnia magna were slightly more sensitive to ATS than MTP effluents. STS effluent water quality was identified as most degraded of the three wastewater treatment systems. Parameters used to assess centralized wastewater treatment plant effluent water quality such as whole effluent toxicity and endocrine active substances appear useful for water quality assessments of decentralized discharges. Aerobic on-site wastewater treatment systems may represent more robust options than traditional septic systems for on-site wastewater treatment in watersheds with appreciable groundwater - surface water exchange. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Predicting Near-Term Water Quality from Satellite Observations of Watershed Conditions

    NASA Astrophysics Data System (ADS)

    Weiss, W. J.; Wang, L.; Hoffman, K.; West, D.; Mehta, A. V.; Lee, C.

    2017-12-01

    Despite the strong influence of watershed conditions on source water quality, most water utilities and water resource agencies do not currently have the capability to monitor watershed sources of contamination with great temporal or spatial detail. Typically, knowledge of source water quality is limited to periodic grab sampling; automated monitoring of a limited number of parameters at a few select locations; and/or monitoring relevant constituents at a treatment plant intake. While important, such observations are not sufficient to inform proactive watershed or source water management at a monthly or seasonal scale. Satellite remote sensing data on the other hand can provide a snapshot of an entire watershed at regular, sub-monthly intervals, helping analysts characterize watershed conditions and identify trends that could signal changes in source water quality. Accordingly, the authors are investigating correlations between satellite remote sensing observations of watersheds and source water quality, at a variety of spatial and temporal scales and lags. While correlations between remote sensing observations and direct in situ measurements of water quality have been well described in the literature, there are few studies that link remote sensing observations across a watershed with near-term predictions of water quality. In this presentation, the authors will describe results of statistical analyses and discuss how these results are being used to inform development of a desktop decision support tool to support predictive application of remote sensing data. Predictor variables under evaluation include parameters that describe vegetative conditions; parameters that describe climate/weather conditions; and non-remote sensing, in situ measurements. Water quality parameters under investigation include nitrogen, phosphorus, organic carbon, chlorophyll-a, and turbidity.

  20. An approach to optimize sample preparation for MALDI imaging MS of FFPE sections using fractional factorial design of experiments.

    PubMed

    Oetjen, Janina; Lachmund, Delf; Palmer, Andrew; Alexandrov, Theodore; Becker, Michael; Boskamp, Tobias; Maass, Peter

    2016-09-01

    A standardized workflow for matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI imaging MS) is a prerequisite for the routine use of this promising technology in clinical applications. We present an approach to develop standard operating procedures for MALDI imaging MS sample preparation of formalin-fixed and paraffin-embedded (FFPE) tissue sections based on a novel quantitative measure of dataset quality. To cover many parts of the complex workflow and simultaneously test several parameters, experiments were planned according to a fractional factorial design of experiments (DoE). The effect of ten different experiment parameters was investigated in two distinct DoE sets, each consisting of eight experiments. FFPE rat brain sections were used as standard material because of low biological variance. The mean peak intensity and a recently proposed spatial complexity measure were calculated for a list of 26 predefined peptides obtained by in silico digestion of five different proteins and served as quality criteria. A five-way analysis of variance (ANOVA) was applied on the final scores to retrieve a ranking of experiment parameters with increasing impact on data variance. Graphical abstract MALDI imaging experiments were planned according to fractional factorial design of experiments for the parameters under study. Selected peptide images were evaluated by the chosen quality metric (structure and intensity for a given peak list), and the calculated values were used as an input for the ANOVA. The parameters with the highest impact on the quality were deduced and SOPs recommended.

  1. Pharmacodynamics of temazepam in primary insomnia: assessment of the value of quantitative electroencephalography and saccadic eye movements in predicting improvement of sleep.

    PubMed

    Tuk, B; Oberyé, J J; Pieters, M S; Schoemaker, R C; Kemp, B; van Gerven, J; Danhof, M; Kamphuisen, H A; Cohen, A F; Breimer, D D; Peck, C C

    1997-10-01

    Quantitative electroencephalographic parameters and saccadic eye movements are frequently used as pharmacodynamic measures of benzodiazepine effect. We investigated the relationship between these measures and the hypnotic effect. The correlation between the pharmacodynamic measures and sleep quality was determined in 21 patients with primary insomnia. The pharmacokinetic-pharmacodynamic relationships were characterized after administration of 20 mg oral temazepam. The hypnotic effect was determined on the basis of polysomnographic sleep recordings and a subjective sleep evaluation questionnaire. Correlations between pharmacodynamic measures and the improvement of sleep were investigated. The pharmacokinetic-pharmacodynamic relationships for the parameters derived from electroencephalography and saccadic eye movements showed considerable interindividual variability. Administration of temazepam led to a significant improvement in the objective parameters sleep period efficiency, wake time after sleep onset, and sleep efficiency and in the subjective assessment of sleep quality. No significant correlations were observed between the pharmacokinetic-pharmacodynamic-derived parameters and the improvement in objective or subjective sleep parameters. In subjects with primary insomnia the administration of 20 mg oral temazepam results in changes in both the pharmacodynamic measures and in quality of sleep. No individual correlations between the pharmacodynamic measures and quality of sleep were observed. We concluded that the investigated pharmacodynamic measures are of value in the first assessment of clinical efficacy and for the selection of the dose(s) to be investigated in subsequent trials that aim at showing clinical efficacy. However, the conclusive quantification of clinical efficacy should be performed only on the basis of the clinical end point itself.

  2. A Bayesian approach to identifying structural nonlinearity using free-decay response: Application to damage detection in composites

    USGS Publications Warehouse

    Nichols, J.M.; Link, W.A.; Murphy, K.D.; Olson, C.C.

    2010-01-01

    This work discusses a Bayesian approach to approximating the distribution of parameters governing nonlinear structural systems. Specifically, we use a Markov Chain Monte Carlo method for sampling the posterior parameter distributions thus producing both point and interval estimates for parameters. The method is first used to identify both linear and nonlinear parameters in a multiple degree-of-freedom structural systems using free-decay vibrations. The approach is then applied to the problem of identifying the location, size, and depth of delamination in a model composite beam. The influence of additive Gaussian noise on the response data is explored with respect to the quality of the resulting parameter estimates.

  3. Correlations of water quality parameters with mutagenicity of chlorinated drinking water samples.

    PubMed

    Schenck, Kathleen M; Sivaganesan, Mano; Rice, Glenn E

    2009-01-01

    Adverse health effects that may result from chronic exposure to mixtures of disinfection by-products (DBPs) present in drinking waters may be linked to both the types and concentrations of DBPs present. Depending on the characteristics of the source water and treatment processes used, both types and concentrations of DBPs found in drinking waters vary substantially. The composition of a drinking-water mixture also may change during distribution. This study evaluated the relationships between mutagenicity, using the Ames assay, and water quality parameters. The study included information on treatment, mutagenicity data, and water quality data for source waters, finished waters, and distribution samples collected from five full-scale drinking water treatment plants, which used chlorine exclusively for disinfection. Four of the plants used surface water sources and the fifth plant used groundwater. Correlations between mutagenicity and water quality parameters are presented. The highest correlation was observed between mutagenicity and the total organic halide concentrations in the treated samples.

  4. Assessment of water quality monitoring for the optimal sensor placement in lake Yahuarcocha using pattern recognition techniques and geographical information systems.

    PubMed

    Jácome, Gabriel; Valarezo, Carla; Yoo, Changkyoo

    2018-03-30

    Pollution and the eutrophication process are increasing in lake Yahuarcocha and constant water quality monitoring is essential for a better understanding of the patterns occurring in this ecosystem. In this study, key sensor locations were determined using spatial and temporal analyses combined with geographical information systems (GIS) to assess the influence of weather features, anthropogenic activities, and other non-point pollution sources. A water quality monitoring network was established to obtain data on 14 physicochemical and microbiological parameters at each of seven sample sites over a period of 13 months. A spatial and temporal statistical approach using pattern recognition techniques, such as cluster analysis (CA) and discriminant analysis (DA), was employed to classify and identify the most important water quality parameters in the lake. The original monitoring network was reduced to four optimal sensor locations based on a fuzzy overlay of the interpolations of concentration variations of the most important parameters.

  5. Field data analysis of boar semen quality.

    PubMed

    Broekhuijse, M L W J; Feitsma, H; Gadella, B M

    2011-09-01

    This contribution provides an overview of approaches to correlate sow fertility data with boar semen quality characteristics. Large data sets of fertility data and ejaculate data are more suitable to analyse effects of semen quality characteristics on field fertility. Variation in fertility in sows is large. The effect of semen factors is relatively small and therefore impossible to find in smaller data sets. Large data sets allow for statistical corrections on both sow- and boar-related parameters. Remaining sow fertility variation can then be assigned to semen quality parameters, which is of huge interest to AI (artificial insemination) companies. Previous studies of Varkens KI Nederland to find the contribution to field fertility of (i) the number of sperm cells in an insemination dose, (ii) the sperm motility and morphological defects and (iii) the age of semen at the moment of insemination are discussed in context of the possibility to apply such knowledge to select boars on the basis of their sperm parameters for AI purposes. © 2011 Blackwell Verlag GmbH.

  6. Real Time Assessment of Potable Water Quality in Distribution Network based on Low Cost Multi-Sensor Array

    NASA Astrophysics Data System (ADS)

    Bhardwaj, Jyotirmoy; Gupta, Karunesh K.; Khatri, Punit

    2018-03-01

    New concepts and techniques are replacing traditional methods of water quality parameters measurement systems. This paper proposed a new way of potable water quality assessment in distribution network using Multi Sensor Array (MSA). Extensive research suggests that following parameters i.e. pH, Dissolved Oxygen (D.O.), Conductivity, Oxygen Reduction Potential (ORP), Temperature and Salinity are most suitable to detect overall quality of potable water. Commonly MSA is not an integrated sensor array on some substrate, but rather comprises a set of individual sensors measuring simultaneously different water parameters all together. Based on research, a MSA has been developed followed by signal conditioning unit and finally, an algorithm for easy user interfacing. A dedicated part of this paper also discusses the platform design and significant results. The Objective of this proposed research is to provide simple, efficient, cost effective and socially acceptable means to detect and analyse water bodies regularly and automatically.

  7. Data quality system using reference dictionaries and edit distance algorithms

    NASA Astrophysics Data System (ADS)

    Karbarz, Radosław; Mulawka, Jan

    2015-09-01

    The real art of management it is important to make smart decisions, what in most of the cases is not a trivial task. Those decisions may lead to determination of production level, funds allocation for investments etc. Most of the parameters in decision-making process such as: interest rate, goods value or exchange rate may change. It is well know that these parameters in the decision-making are based on the data contained in datamarts or data warehouse. However, if the information derived from the processed data sets is the basis for the most important management decisions, it is required that the data is accurate, complete and current. In order to achieve high quality data and to gain from them measurable business benefits, data quality system should be used. The article describes the approach to the problem, shows the algorithms in details and their usage. Finally the test results are provide. Test results show the best algorithms (in terms of quality and quantity) for different parameters and data distribution.

  8. Gluten-Free Precooked Rice-Yellow Pea Pasta: Effect of Extrusion-Cooking Conditions on Phenolic Acids Composition, Selected Properties and Microstructure.

    PubMed

    Bouasla, Abdallah; Wójtowicz, Agnieszka; Zidoune, Mohammed Nasereddine; Olech, Marta; Nowak, Renata; Mitrus, Marcin; Oniszczuk, Anna

    2016-05-01

    Rice/yellow pea flour blend (2/1 ratio) was used to produce gluten-free precooked pasta using a single-screw modified extrusion-cooker TS-45. The effect of moisture content (28%, 30%, and 32%) and screw speed (60, 80, and 100 rpm) on some quality parameters was assessed. The phenolic acids profile and selected pasta properties were tested, like pasting properties, water absorption capacity, cooking loss, texture characteristics, microstructure, and sensory overall acceptability. Results indicated that dough moisture content influenced all tested quality parameters of precooked pasta except firmness. Screw speed showed an effect only on some quality parameters. The extrusion-cooking process at 30% of dough moisture with 80 rpm is appropriate to obtain rice-yellow pea precooked pasta with high content of phenolics and adequate quality. These pasta products exhibited firm texture, low stickiness, and regular and compact interne structure confirmed by high score in sensory overall acceptability. © 2016 Institute of Food Technologists®

  9. Spatial and Temporal Variation of Water Quality in the Bertam Catchment, Cameron Highlands, Malaysia.

    PubMed

    Rasul, M G; Islam, Mir Sujaul; Yunus, Rosli Bin Mohd; Mokhtar, Mazlin Bin; Alam, Lubna; Yahaya, F M

    2017-12-01

      The spatio-temporal variability of water quality associated with anthropogenic activities was studied for the Bertam River and its main tributaries within the Bertam Catchment, Cameron Highlands, Malaysia. A number of physico-chemical parameters of collected samples were analyzed to evaluate their spatio-temporal variability. Nonparametric statistical analysis showed significant temporal and spatial differences (p < 0.05) in most of the parameters across the catchment. Parameters except dissolved oxygen and chemical oxygen demand displayed higher values in rainy season. The higher concentration of total suspended solids was caused by massive soil erosion and sedimentation. Seasonal variations in contaminant concentrations are largely affected by precipitation and anthropogenic influences. Untreated domestic wastewater discharge as well as agricultural runoff significantly influenced the water quality. Poor agricultural practices and development activities at slope areas also affected the water quality within the catchment. The analytical results provided a basis for protection of river environments and ecological restoration in mountainous Bertam Catchment.

  10. Sensoring Fusion Data from the Optic and Acoustic Emissions of Electric Arcs in the GMAW-S Process for Welding Quality Assessment

    PubMed Central

    Alfaro, Sadek Crisóstomo Absi; Cayo, Eber Huanca

    2012-01-01

    The present study shows the relationship between welding quality and optical-acoustic emissions from electric arcs, during welding runs, in the GMAW-S process. Bead on plate welding tests was carried out with pre-set parameters chosen from manufacturing standards. During the welding runs interferences were induced on the welding path using paint, grease or gas faults. In each welding run arc voltage, welding current, infrared and acoustic emission values were acquired and parameters such as arc power, acoustic peaks rate and infrared radiation rate computed. Data fusion algorithms were developed by assessing known welding quality parameters from arc emissions. These algorithms have showed better responses when they are based on more than just one sensor. Finally, it was concluded that there is a close relation between arc emissions and quality in welding and it can be measured from arc emissions sensing and data fusion algorithms. PMID:22969330

  11. Chemometric studies of water quality parameters of Sankarankovil block of Tirunelveli, Tamilnadu.

    PubMed

    Alagumuthu, G; Rajan, M

    2010-09-01

    The fluoride concentration in ground water was determined in Sankarankovil block of Tirunelveli district of Tamilnadu (India) where it is the only source of drinking water. Various other water quality parameters such as pH, electrical conductivity total hardness and total alkalinity as well as calcium, magnesium, carbonate, bicarbonate and chloride concentrations were also measured. A systematic calculation of correlation coefficient among different physico-chemical parameters was performed. The analytical results indicated considerable variations among the analyzed samples with respect to their chemical composition. Majority of the samples do not comply with Indian as well as WHO water quality standards. The fluoride concentration in the ground water of these villages varied from 0.66 to 3.84 mg l(-1), causes dental fluorosis among people especially children of these villages. The high and low fluoride containing areas were located using isopleth mapping technique. Overall water quality was found unsatisfactory for drinking purposes without any prior treatment except at few locations out of 50 villages.

  12. Groundwater quality in some villages of Haryana, India: focus on fluoride and fluorosis.

    PubMed

    Meenakshi; Garg, V K; Kavita; Renuka; Malik, Anju

    2004-01-02

    The fluoride concentration in underground water was determined in four villages of Jind district of Haryana state (India) where it is the only source of drinking water. Various other water quality parameters such as pH, electrical conductivity, total dissolved salts, total hardness, total alkalinity as well as sodium, potassium, calcium, magnesium, carbonate, bicarbonate, chloride and sulfate concentrations were also measured. A systematic calculation of correlation coefficients among different physico-chemical parameters was performed. The analytical results indicated considerable variations among the analyzed samples with respect to their chemical composition. Majority of the samples do not comply with Indian as well as WHO standards for most of the water quality parameters measured. The fluoride concentration in the underground water of these villages varied from 0.3 to 6.9 mg/l, causing dental fluorosis among people especially children of these villages. Overall water quality was found unsatisfactory for drinking purposes without any prior treatment except at eight locations out of 60.

  13. Variability of Remote Sensing Spectral Indices in Boreal Lake Basins

    NASA Astrophysics Data System (ADS)

    Hakala, T.; Pölönen, I.; Honkavaara, E.; Näsi, R.; Hakala, T.; Lindfors, A.

    2018-05-01

    Remotely sensed hyperspectral data has widely been used to determine water quality parameters in oceanic waters. However in freshwater basins the dependence between the hyperspectral data and the parameters is more complicated. In this work some ideas are presented concerning the study of this dependence. The data used in this study were collected from the lake Hiidenvesi in southern Finland. The hyperspectral data consists of reflectances in 36 bands in the wavelength area 508…878 nm and the separately measured water quality parameters are turbidity, blue-green algae, chlorophyll, pH and dissolved oxygen. Hyperspectral data was used as bare band reflectances, but also in the form of two simple spectral indices: ratio A / B and difference A - B, where A and B go through all the bands. The correlations of the indices with the parameters were presented visually as 1- or 2-dimensional arrays. To examine the significance on the results of different variables, the data was classified in two different ways: the natural basins and the values of the water quality parameters. It was noticed that the variability of the correlation arrays was particularly strong among different basins in both the magnitude of correlation and the best performing indices. Further studies are needed to clarify which features of the basins are of most importance in predicting the shapes of the correlation arrays.

  14. Response of aquatic macro-invertebrate diversity to environmental factors along the Lower Komati River in Swaziland

    NASA Astrophysics Data System (ADS)

    Dlamini, Vuyisile; Hoko, Zvikomborero; Murwira, Amon; Magagula, Cebisile

    This paper assessed macro-invertebrates diversity as an indicator of aquatic ecosystem health in the Lower Komati River. It also investigated whether this diversity is a function of physico-chemical water quality parameters along an area with major agricultural activities. Bio-assessment of aquatic macro-invertebrates present in the Lower Komati River was carried out at seven sites on the river over 3 months. Water samples were also collected at these sites and analysed for pH, dissolved oxygen, electrical conductivity, turbidity, nitrates, ammonia and ortho-phosphates according to standard methods. It was found out that species diversity along agricultural fields was not significantly different ( p > 0.05) between successive sites. However, nitrate and turbidity among the physico-chemical parameters indicated a significant variation of mean values ( p < 0.05) between sites. With the exception of turbidity, no significant relationship ( p > 0.05) was found between diversity and water quality parameters. Principal Component Analysis also demonstrated the influence of turbidity in the sub-catchments as it was the only parameter that showed a significant loading in all Principal Components. Turbidity seems to be the main parameter influencing aquatic macro-invertebrate diversity in the Lower Komati River at the time of study. The study recommends further studies to determine the seasonal variation of the impact of water quality on macro-invertebrates diversity.

  15. New approach for rapid assessment of trophic status of Yellow Sea and East China Sea using easy-to-measure parameters

    NASA Astrophysics Data System (ADS)

    Kong, Xianyu; Liu, Yanfang; Jian, Huimin; Su, Rongguo; Yao, Qingzhen; Shi, Xiaoyong

    2017-10-01

    To realize potential cost savings in coastal monitoring programs and provide timely advice for marine management, there is an urgent need for efficient evaluation tools based on easily measured variables for the rapid and timely assessment of estuarine and offshore eutrophication. In this study, using parallel factor analysis (PARAFAC), principal component analysis (PCA), and discriminant function analysis (DFA) with the trophic index (TRIX) for reference, we developed an approach for rapidly assessing the eutrophication status of coastal waters using easy-to-measure parameters, including chromophoric dissolved organic matter (CDOM), fluorescence excitation-emission matrices, CDOM UV-Vis absorbance, and other water-quality parameters (turbidity, chlorophyll a, and dissolved oxygen). First, we decomposed CDOM excitation-emission matrices (EEMs) by PARAFAC to identify three components. Then, we applied PCA to simplify the complexity of the relationships between the water-quality parameters. Finally, we used the PCA score values as independent variables in DFA to develop a eutrophication assessment model. The developed model yielded classification accuracy rates of 97.1%, 80.5%, 90.3%, and 89.1% for good, moderate, and poor water qualities, and for the overall data sets, respectively. Our results suggest that these easy-to-measure parameters could be used to develop a simple approach for rapid in-situ assessment and monitoring of the eutrophication of estuarine and offshore areas.

  16. Evaluation of multivariate linear regression and artificial neural networks in prediction of water quality parameters

    PubMed Central

    2014-01-01

    This paper examined the efficiency of multivariate linear regression (MLR) and artificial neural network (ANN) models in prediction of two major water quality parameters in a wastewater treatment plant. Biochemical oxygen demand (BOD) and chemical oxygen demand (COD) as well as indirect indicators of organic matters are representative parameters for sewer water quality. Performance of the ANN models was evaluated using coefficient of correlation (r), root mean square error (RMSE) and bias values. The computed values of BOD and COD by model, ANN method and regression analysis were in close agreement with their respective measured values. Results showed that the ANN performance model was better than the MLR model. Comparative indices of the optimized ANN with input values of temperature (T), pH, total suspended solid (TSS) and total suspended (TS) for prediction of BOD was RMSE = 25.1 mg/L, r = 0.83 and for prediction of COD was RMSE = 49.4 mg/L, r = 0.81. It was found that the ANN model could be employed successfully in estimating the BOD and COD in the inlet of wastewater biochemical treatment plants. Moreover, sensitive examination results showed that pH parameter have more effect on BOD and COD predicting to another parameters. Also, both implemented models have predicted BOD better than COD. PMID:24456676

  17. MASTOS: Mammography Simulation Tool for design Optimization Studies.

    PubMed

    Spyrou, G; Panayiotakis, G; Tzanakos, G

    2000-01-01

    Mammography is a high quality imaging technique for the detection of breast lesions, which requires dedicated equipment and optimum operation. The design parameters of a mammography unit have to be decided and evaluated before the construction of such a high cost of apparatus. The optimum operational parameters also must be defined well before the real breast examination. MASTOS is a software package, based on Monte Carlo methods, that is designed to be used as a simulation tool in mammography. The input consists of the parameters that have to be specified when using a mammography unit, and also the parameters specifying the shape and composition of the breast phantom. In addition, the input may specify parameters needed in the design of a new mammographic apparatus. The main output of the simulation is a mammographic image and calculations of various factors that describe the image quality. The Monte Carlo simulation code is PC-based and is driven by an outer shell of a graphical user interface. The entire software package is a simulation tool for mammography and can be applied in basic research and/or in training in the fields of medical physics and biomedical engineering as well as in the performance evaluation of new designs of mammography units and in the determination of optimum standards for the operational parameters of a mammography unit.

  18. Contrast-detail phantom scoring methodology.

    PubMed

    Thomas, Jerry A; Chakrabarti, Kish; Kaczmarek, Richard; Romanyukha, Alexander

    2005-03-01

    Published results of medical imaging studies which make use of contrast detail mammography (CDMAM) phantom images for analysis are difficult to compare since data are often not analyzed in the same way. In order to address this situation, the concept of ideal contrast detail curves is suggested. The ideal contrast detail curves are constructed based on the requirement of having the same product of the diameter and contrast (disk thickness) of the minimal correctly determined object for every row of the CDMAM phantom image. A correlation and comparison of five different quality parameters of the CDMAM phantom image determined for obtained ideal contrast detail curves is performed. The image quality parameters compared include: (1) contrast detail curve--a graph correlation between "minimal correct reading" diameter and disk thickness; (2) correct observation ratio--the ratio of the number of correctly identified objects to the actual total number of objects multiplied by 100; (3) image quality figure--the sum of the product of the diameter of the smallest scored object and its relative contrast; (4) figure-of-merit--the zero disk diameter value obtained from extrapolation of the contrast detail curve to the origin (e.g., zero disk diameter); and (5) k-factor--the product of the thickness and the diameter of the smallest correctly identified disks. The analysis carried out showed the existence of a nonlinear relationship between the above parameters, which means that use of different parameters of CDMAM image quality potentially can cause different conclusions about changes in image quality. Construction of the ideal contrast detail curves for CDMAM phantom is an attempt to determine the quantitative limits of the CDMAM phantom as employed for image quality evaluation. These limits are determined by the relationship between certain parameters of a digital mammography system and the set of the gold disks sizes in the CDMAM phantom. Recommendations are made on selections of CDMAM phantom regions which should be used for scoring at different image quality and which scoring methodology may be most appropriate. Special attention is also paid to the use of the CDMAM phantom for image quality assessment of digital mammography systems particularly in the vicinity of the Nyquist frequency.

  19. Diffusion-weighted imaging of the liver with multiple b values: effect of diffusion gradient polarity and breathing acquisition on image quality and intravoxel incoherent motion parameters--a pilot study.

    PubMed

    Dyvorne, Hadrien A; Galea, Nicola; Nevers, Thomas; Fiel, M Isabel; Carpenter, David; Wong, Edmund; Orton, Matthew; de Oliveira, Andre; Feiweier, Thorsten; Vachon, Marie-Louise; Babb, James S; Taouli, Bachir

    2013-03-01

    To optimize intravoxel incoherent motion (IVIM) diffusion-weighted (DW) imaging by estimating the effects of diffusion gradient polarity and breathing acquisition scheme on image quality, signal-to-noise ratio (SNR), IVIM parameters, and parameter reproducibility, as well as to investigate the potential of IVIM in the detection of hepatic fibrosis. In this institutional review board-approved prospective study, 20 subjects (seven healthy volunteers, 13 patients with hepatitis C virus infection; 14 men, six women; mean age, 46 years) underwent IVIM DW imaging with four sequences: (a) respiratory-triggered (RT) bipolar (BP) sequence, (b) RT monopolar (MP) sequence, (c) free-breathing (FB) BP sequence, and (d) FB MP sequence. Image quality scores were assessed for all sequences. A biexponential analysis with the Bayesian method yielded true diffusion coefficient (D), pseudodiffusion coefficient (D*), and perfusion fraction (PF) in liver parenchyma. Mixed-model analysis of variance was used to compare image quality, SNR, IVIM parameters, and interexamination variability between the four sequences, as well as the ability to differentiate areas of liver fibrosis from normal liver tissue. Image quality with RT sequences was superior to that with FB acquisitions (P = .02) and was not affected by gradient polarity. SNR did not vary significantly between sequences. IVIM parameter reproducibility was moderate to excellent for PF and D, while it was less reproducible for D*. PF and D were both significantly lower in patients with hepatitis C virus than in healthy volunteers with the RT BP sequence (PF = 13.5% ± 5.3 [standard deviation] vs 9.2% ± 2.5, P = .038; D = [1.16 ± 0.07] × 10(-3) mm(2)/sec vs [1.03 ± 0.1] × 10(-3) mm(2)/sec, P = .006). The RT BP DW imaging sequence had the best results in terms of image quality, reproducibility, and ability to discriminate between healthy and fibrotic liver with biexponential fitting.

  20. Estimation of water quality parameters of inland and coastal waters with the use of a toolkit for processing of remote sensing data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dekker, A.G.; Hoogenboom, H.J.; Rijkeboer, M.

    1997-06-01

    Deriving thematic maps of water quality parameters from a remote sensing image requires a number of processing steps, such as calibration, atmospheric correction, air/water interface correction, and application of water quality algorithms. A prototype software environment has recently been developed that enables the user to perform and control these processing steps. Main parts of this environment are: (i) access to the MODTRAN 3 radiative transfer code for removing atmospheric and air-water interface influences, (ii) a tool for analyzing of algorithms for estimating water quality and (iii) a spectral database, containing apparent and inherent optical properties and associated water quality parameters.more » The use of the software is illustrated by applying implemented algorithms for estimating chlorophyll to data from a spectral library of Dutch inland waters with CHL ranging from 1 to 500 pg 1{sup -1}. The algorithms currently implemented in the Toolkit software are recommended for optically simple waters, but for optically complex waters development of more advanced retrieval methods is required.« less

  1. Monitoring and assessment of water quality of Tasik Cempaka, Bangi

    NASA Astrophysics Data System (ADS)

    Sabri, Nurul Ain Syahirah Mohamad; Abdullah, Md Pauzi; Mat, Sohif

    2014-09-01

    A study was carried out to determine the status of water quality of Tasik Cempaka which is a part of Sg. Air Itam, located near the Bangi industrial area. The study was carried out for eight months from May and to December 2013. Eight sampling stations were selected from upstream to downstream of Sg. Air Itam which represent the entire body of the lake water. There are 8 parameters measured and Water Quality Indices (WQI) was calculated and classified according to the National Water Quality Standard (NWQS). The physical and chemical parameters were temperature, pH, conductivity, dissolve oxygen (DO), total suspended solid (TSS), ammoniacal nitrogen (AN), chemical oxygen demand (COD) and biochemical oxygen demand (BOD). Among parameters that are affected by pollution is AN, COD and BOD. Classification by WQI shows that the average for all sampling was 54 (dry) and 52 (wet). Both are of class III according to National Water Quality Standard (NWQS) indicating slightly polluted. This is mainly due to drainage from Bangi Golf Resort and Bangi-Putrajaya Hotel. Other factors are activities around Sg. Air Itam such as municipal activities, settlements and manufacturing industries.

  2. Statistical, time series, and fractal analysis of full stretch of river Yamuna (India) for water quality management.

    PubMed

    Parmar, Kulwinder Singh; Bhardwaj, Rashmi

    2015-01-01

    River water is a major resource of drinking water on earth. Management of river water is highly needed for surviving. Yamuna is the main river of India, and monthly variation of water quality of river Yamuna, using statistical methods have been compared at different sites for each water parameters. Regression, correlation coefficient, autoregressive integrated moving average (ARIMA), box-Jenkins, residual autocorrelation function (ACF), residual partial autocorrelation function (PACF), lag, fractal, Hurst exponent, and predictability index have been estimated to analyze trend and prediction of water quality. Predictive model is useful at 95% confidence limits and all water parameters reveal platykurtic curve. Brownian motion (true random walk) behavior exists at different sites for BOD, AMM, and total Kjeldahl nitrogen (TKN). Quality of Yamuna River water at Hathnikund is good, declines at Nizamuddin, Mazawali, Agra D/S, and regains good quality again at Juhikha. For all sites, almost all parameters except potential of hydrogen (pH), water temperature (WT) crosses the prescribed limits of World Health Organization (WHO)/United States Environmental Protection Agency (EPA).

  3. Micro CSI: A Microbial Citizen Science Initiative in Urban Watersheds

    EPA Science Inventory

    Across the Nation, a number of citizen science efforts have been conducted to monitor water quality. Efforts have included monitoring of bacteriological parameters (E. coli, enterococci, and fecal coliforms) and/or physicochemical parameters (temperature, turbidity, pH, conducti...

  4. WSN based indoor air quality monitoring in classrooms

    NASA Astrophysics Data System (ADS)

    Wang, S. K.; Chew, S. P.; Jusoh, M. T.; Khairunissa, A.; Leong, K. Y.; Azid, A. A.

    2017-03-01

    Indoor air quality monitoring is essential as the human health is directly affected by indoor air quality. This paper presents the investigations of the impact of undergraduate students' concentration during lecture due to the indoor air quality in classroom. Three environmental parameters such as temperature, relative humidity and concentration of carbon dioxide are measured using wireless sensor network based air quality monitoring system. This simple yet reliable system is incorporated with DHT-11 and MG-811 sensors. Two classrooms were selected to install the monitoring system. The level of indoor air quality were measured and students' concentration was assessed using intelligent test during normal lecturing section. The test showed significant correlation between the collected environmental parameters and the students' level of performances in their study.

  5. Modeling and optimization of joint quality for laser transmission joint of thermoplastic using an artificial neural network and a genetic algorithm

    NASA Astrophysics Data System (ADS)

    Wang, Xiao; Zhang, Cheng; Li, Pin; Wang, Kai; Hu, Yang; Zhang, Peng; Liu, Huixia

    2012-11-01

    A central composite rotatable experimental design(CCRD) is conducted to design experiments for laser transmission joining of thermoplastic-Polycarbonate (PC). The artificial neural network was used to establish the relationships between laser transmission joining process parameters (the laser power, velocity, clamp pressure, scanning number) and joint strength and joint seam width. The developed mathematical models are tested by analysis of variance (ANOVA) method to check their adequacy and the effects of process parameters on the responses and the interaction effects of key process parameters on the quality are analyzed and discussed. Finally, the desirability function coupled with genetic algorithm is used to carry out the optimization of the joint strength and joint width. The results show that the predicted results of the optimization are in good agreement with the experimental results, so this study provides an effective method to enhance the joint quality.

  6. Quantitative analysis of aircraft multispectral-scanner data and mapping of water-quality parameters in the James River in Virginia

    NASA Technical Reports Server (NTRS)

    Johnson, R. W.; Bahn, G. S.

    1977-01-01

    Statistical analysis techniques were applied to develop quantitative relationships between in situ river measurements and the remotely sensed data that were obtained over the James River in Virginia on 28 May 1974. The remotely sensed data were collected with a multispectral scanner and with photographs taken from an aircraft platform. Concentration differences among water quality parameters such as suspended sediment, chlorophyll a, and nutrients indicated significant spectral variations. Calibrated equations from the multiple regression analysis were used to develop maps that indicated the quantitative distributions of water quality parameters and the dispersion characteristics of a pollutant plume entering the turbid river system. Results from further analyses that use only three preselected multispectral scanner bands of data indicated that regression coefficients and standard errors of estimate were not appreciably degraded compared with results from the 10-band analysis.

  7. Effects of Irradiation Dose on Sterility Induction and Quality Parameters of Drosophila suzukii (Diptera: Drosophilidae).

    PubMed

    Krüger, Alexandra Peter; Schlesener, Daniele Cristine Hoffmann; Martins, Liliane Nachtigall; Wollmann, Jutiane; Deprá, Maríndia; Garcia, Flávio Roberto Mello

    2018-04-02

    Drosophila suzukii (Matsumura, 1931) (Diptera: Drosophilidae) is a widely distributed pest of soft-skinned and stone fruits that is controlled mainly with pesticides. An alternative to the chemical control is the sterile insect technique (SIT), an ecologically friendly method of pest management that could be used against D. suzukii. The objective of the present study was to evaluate the effects of gamma radiation on reproductive sterility, ovarian morphometry, and quality parameters of D. suzukii. Full female sterility was achieved at 75 Gy, while an adequate level of male sterility (99.67%) was obtained at 200 Gy. The ovarian size showed an exponential decay in function of irradiation dose increase. There was no significant influence of irradiation dose on the quality parameters evaluated. Our data suggest that gamma radiation can be recommended to be used in an SIT program for D. suzukii.

  8. Prevalence of individual and bulk tank milk antibodies of bovine herpesvirus type 1 and its relation to milk quality parameters on dairy farms in Catalonia (north-east Spain)

    PubMed Central

    Armengol, Ramon; Villalba, Daniel; Coma, Ester; Porquet, Lourdes; Jubert, Anna

    2017-01-01

    Bovine herpesvirus type 1 (BoHV-1) is the causative agent for infectious bovine rhinotracheitis and infectious pustular vulvovaginitis in cows or balanoposthitis in bulls. In this study, individual and bulk tank milk (BTM) samples from 5 Catalan dairy farms with different control strategies against BoHV-1 were analysed during the course of a year for milk quality parameters and glycoprotein E (gE) antibodies. Detection of gE antibodies was carried out with ELISA techniques. Prevalence of BoHV-1 varied between farms, and was stable during the study in individual and BTM samples. Comparing the antibody results of samples with milk quality parameters, positive samples with higher levels of antibodies corresponded to lower lactose and to higher percentages of fat and somatic cells. PMID:28761669

  9. Financial gains and risks in pay-for-performance bonus algorithms.

    PubMed

    Cromwell, Jerry; Drozd, Edward M; Smith, Kevin; Trisolini, Michael

    2007-01-01

    Considerable attention has been given to evidence-based process indicators associated with quality of care, while much less attention has been given to the structure and key parameters of the various pay-for-performance (P4P) bonus and penalty arrangements using such measures. In this article we develop a general model of quality payment arrangements and discuss the advantages and disadvantages of the key parameters. We then conduct simulation analyses of four general P4P payment algorithms by varying seven parameters, including indicator weights, indicator intercorrelation, degree of uncertainty regarding intervention effectiveness, and initial baseline rates. Bonuses averaged over several indicators appear insensitive to weighting, correlation, and the number of indicators. The bonuses are sensitive to disease manager perceptions of intervention effectiveness, facing challenging targets, and the use of actual-to-target quality levels versus rates of improvement over baseline.

  10. Inverse determination of the penalty parameter in penalized weighted least-squares algorithm for noise reduction of low-dose CBCT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Jing; Guan, Huaiqun; Solberg, Timothy

    2011-07-15

    Purpose: A statistical projection restoration algorithm based on the penalized weighted least-squares (PWLS) criterion can substantially improve the image quality of low-dose CBCT images. The performance of PWLS is largely dependent on the choice of the penalty parameter. Previously, the penalty parameter was chosen empirically by trial and error. In this work, the authors developed an inverse technique to calculate the penalty parameter in PWLS for noise suppression of low-dose CBCT in image guided radiotherapy (IGRT). Methods: In IGRT, a daily CBCT is acquired for the same patient during a treatment course. In this work, the authors acquired the CBCTmore » with a high-mAs protocol for the first session and then a lower mAs protocol for the subsequent sessions. The high-mAs projections served as the goal (ideal) toward, which the low-mAs projections were to be smoothed by minimizing the PWLS objective function. The penalty parameter was determined through an inverse calculation of the derivative of the objective function incorporating both the high and low-mAs projections. Then the parameter obtained can be used for PWLS to smooth the noise in low-dose projections. CBCT projections for a CatPhan 600 and an anthropomorphic head phantom, as well as for a brain patient, were used to evaluate the performance of the proposed technique. Results: The penalty parameter in PWLS was obtained for each CBCT projection using the proposed strategy. The noise in the low-dose CBCT images reconstructed from the smoothed projections was greatly suppressed. Image quality in PWLS-processed low-dose CBCT was comparable to its corresponding high-dose CBCT. Conclusions: A technique was proposed to estimate the penalty parameter for PWLS algorithm. It provides an objective and efficient way to obtain the penalty parameter for image restoration algorithms that require predefined smoothing parameters.« less

  11. Quantitative evaluation of water quality in the coastal zone by remote sensing

    NASA Technical Reports Server (NTRS)

    James, W. P.

    1971-01-01

    Remote sensing as a tool in a waste management program is discussed. By monitoring both the pollution sources and the environmental quality, the interaction between the components of the exturaine system was observed. The need for in situ sampling is reduced with the development of improved calibrated, multichannel sensors. Remote sensing is used for: (1) pollution source determination, (2) mapping the influence zone of the waste source on water quality parameters, and (3) estimating the magnitude of the water quality parameters. Diffusion coefficients and circulation patterns can also be determined by remote sensing, along with subtle changes in vegetative patterns and density.

  12. Assessing air quality in Aksaray with time series analysis

    NASA Astrophysics Data System (ADS)

    Kadilar, Gamze Özel; Kadilar, Cem

    2017-04-01

    Sulphur dioxide (SO2) is a major air pollutant caused by the dominant usage of diesel, petrol and fuels by vehicles and industries. One of the most air-polluted city in Turkey is Aksaray. Hence, in this study, the level of SO2 is analyzed in Aksaray based on the database monitored at air quality monitoring station of Turkey. Seasonal Autoregressive Integrated Moving Average (SARIMA) approach is used to forecast the level of SO2 air quality parameter. The results indicate that the seasonal ARIMA model provides reliable and satisfactory predictions for the air quality parameters and expected to be an alternative tool for practical assessment and justification.

  13. Identification of Important Parameter from Leachate Solid Waste Landfill on Water Quality, Case Study of Pesanggrahan River

    NASA Astrophysics Data System (ADS)

    Yanidar, R.; Hartono, D. M.; Moersidik, S. S.

    2018-03-01

    Cipayung Landfill takes waste generation from Depok City approximately ± 750 tons/day of solid waste. The south and west boundaries of the landfill is Pesanggarahan River which 200m faraway. The objectives of this study are to indicate an important parameter which greatly affects the water quality of Pesanggrahan River and purpose the dynamic model for improving our understanding of the dynamic behavior that captures the interactions and feedbacks important parameter in river in order to identify and assess the effects of the treated leachate from final solid waste disposal activity as it responds to changes over time in the river. The high concentrations of BOD and COD are not the only cause significantly affect the quality of the pesanggrahan water, it also because the river has been contaminated in the upstream area. It need the water quality model to support the effectiveness calculation of activities for preventing a selected the pollutant sources the model should be developed for simulating and predicting the trend of water quality performance in Pesanggrahan River which can potentially be used by policy makers in strategic management to sustain river water quality as raw drinking water.

  14. Water quality study of Sunter River in Jakarta, Indonesia

    NASA Astrophysics Data System (ADS)

    Martinus, Y.; Astono, W.; Hendrawan, D.

    2018-01-01

    Sunter River flows in the city of Jakarta with the designation of river water for agricultural purposes, and can be utilized for urban business and hydroelectric power industry. This study aims to determine the Sunter River water quality based on physical and chemical parameters. Water sampling was conducted 2 times which done in April and May with 5 sampling stations for measuring. The samples was analayzed in the laboratory according SNI methods for parameters BOD, COD, PO4 3-, NO3, Oil & Grease and Detergents. The quality status of Sunter River is determined by the Pollutant Index method. The results show that the water quality of Sunter River is influenced by organic parameter as dominant pollutant with COD concentration ranging from 48 mg/l - 182.4 mg/l and BOD concentration ranging from 14.69 mg/L - 98.91 mg/L. The Pollution Index calculation results show that the water quality status of Sunter River is moderate polluted with IP 6.47. The source of pollutants generally comes from the urban drainage channels, tributaries, and slaughtering industry. The results of this study expected to be use by the government to improve the water quality of Sunter River for better environment.

  15. Parametric Optimization Of Gas Metal Arc Welding Process By Using Grey Based Taguchi Method On Aisi 409 Ferritic Stainless Steel

    NASA Astrophysics Data System (ADS)

    Ghosh, Nabendu; Kumar, Pradip; Nandi, Goutam

    2016-10-01

    Welding input process parameters play a very significant role in determining the quality of the welded joint. Only by properly controlling every element of the process can product quality be controlled. For better quality of MIG welding of Ferritic stainless steel AISI 409, precise control of process parameters, parametric optimization of the process parameters, prediction and control of the desired responses (quality indices) etc., continued and elaborate experiments, analysis and modeling are needed. A data of knowledge - base may thus be generated which may be utilized by the practicing engineers and technicians to produce good quality weld more precisely, reliably and predictively. In the present work, X-ray radiographic test has been conducted in order to detect surface and sub-surface defects of weld specimens made of Ferritic stainless steel. The quality of the weld has been evaluated in terms of yield strength, ultimate tensile strength and percentage of elongation of the welded specimens. The observed data have been interpreted, discussed and analyzed by considering ultimate tensile strength ,yield strength and percentage elongation combined with use of Grey-Taguchi methodology.

  16. Intelligent methods for the process parameter determination of plastic injection molding

    NASA Astrophysics Data System (ADS)

    Gao, Huang; Zhang, Yun; Zhou, Xundao; Li, Dequn

    2018-03-01

    Injection molding is one of the most widely used material processing methods in producing plastic products with complex geometries and high precision. The determination of process parameters is important in obtaining qualified products and maintaining product quality. This article reviews the recent studies and developments of the intelligent methods applied in the process parameter determination of injection molding. These intelligent methods are classified into three categories: Case-based reasoning methods, expert system- based methods, and data fitting and optimization methods. A framework of process parameter determination is proposed after comprehensive discussions. Finally, the conclusions and future research topics are discussed.

  17. Electrostatic and structural similarity of classical and non-classical lactam compounds

    NASA Astrophysics Data System (ADS)

    Coll, Miguel; Frau, Juan; Vilanova, Bartolomé; Donoso, Josefa; Muñoz, Francisco

    2001-09-01

    Various electrostatic and structural parameters for a series of classical and non-classical β-lactams were determined and compared in order to ascertain whether some specific β-lactams possess antibacterial or β-lactamase inhibitory properties. The electrostatic parameters obtained, based on the Distributed Multipole Analysis (DMA) of high-quality wavefunctions for the studied structures, suggest that some non-classical β-lactams effectively inhibit the action of β-lactamases. As shown in this work, such electrostatic parameters provide much more reliable information about the antibacterial and inhibitory properties of β-lactams than do structural parameters.

  18. Biomonitoring of water quality of the Osumi, Devolli, and Shkumbini rivers through benthic macroinvertebrates and chemical parameters.

    PubMed

    Duka, Sonila; Pepa, Bledar; Keci, Erjola; Paparisto, Anila; Lazo, Pranvera

    2017-04-16

    Environmental monitoring of river water quality in Albania, using biological and chemical parameters, is a fast and effective way to assess the quality of water bodies.The aim of this study was to investigate Ephemeroptera, Plecoptera and Trichoptera (EPT), Biotic index-Richness using macroinvertebrates to assess the water quality, with special reference to nutrient (phosphorus and nitrogen) levels in the Devolli, Shkumbini and Osumi rivers. Our objective was to investigate the relationships between the measures of benthic macroinvertebrate communities and nutrient concentrations to assess water quality. The rivers' benthic macroinvertebrates were collected during different seasons in 2012. The biological and chemical parameters used in the current study identified them as quick indicators of water quality assessment. The total number of macroinvertebrate individuals (n = 15,006) (Osumi river: n = 5,546 organisms; Devolli river: n = 3,469 organisms; and Shkumbini river: n = 5,991 organisms), together with the EPT group (Ephemeroptera, Plecoptera, and Trichoptera), showed that the water quality at the river stations during the above-mentioned period belonged to Classes II and III (fair water quality and good water quality, respectively). The classification of the water quality was also based on the nitrogen and total phosphorus contents. The pollution tolerance levels of macroinvertebrate taxa varied from the non-tolerating forms encountered in environments with low pollution levels to the tolerating forms that are typical of environments with considerable pollution levels.

  19. Analysis of semen parameters in a young cohort of cancer patients.

    PubMed

    DiNofia, Amanda M; Wang, Xingmei; Yannekis, Gia; Ogle, Sue; Hobbie, Wendy L; Carlson, Claire A; Ginsberg, Jill P

    2017-02-01

    Infertility can be the result of some common cancer treatments and can significantly impact quality of life. Semen cryopreservation allows for fertility preservation. We analyzed the semen parameters of specimens collected from pubertal males from the Children's Hospital of Philadelphia (CHOP) in order to expand current knowledge on the quality of these specimens and inform a standard clinical practice. Males who were at least Tanner stage III and newly diagnosed with cancer at CHOP were approached regarding sperm banking. The success and quality of the samples collected were analyzed and compared in relation to prior treatment, age, and diagnosis. From 399 patients approached for semen collection, 339 (85%) attempted to bank sperm, of which 265 (78%) were successful and 60 (15%) refused to participate. Therapy prior to sperm banking significantly impacted a successful collection (P < 0.01). Only 16.9% of the untreated patients were azoospermic, whereas 84.0% of the treated subjects were azoospermic. Older patients were less likely to be azoospermic and have a greater quality collection when compared with younger patients (P < 0.01). However, 65% of our youngest patients still were able to cryopreserve semen. There was no difference in azoospermia across diagnostic groups (P = 0.35), though there were differences in quality of semen parameters across diagnoses. Our data support that sperm banking pubertal males prior to the initiation of therapy is feasible. While there were differences in quality of semen parameters across age and diagnostic groups, most males, regardless of age or diagnosis, had adequate specimens for cryopreservation. © 2016 Wiley Periodicals, Inc.

  20. Modeling Source Water Threshold Exceedances with Extreme Value Theory

    NASA Astrophysics Data System (ADS)

    Rajagopalan, B.; Samson, C.; Summers, R. S.

    2016-12-01

    Variability in surface water quality, influenced by seasonal and long-term climate changes, can impact drinking water quality and treatment. In particular, temperature and precipitation can impact surface water quality directly or through their influence on streamflow and dilution capacity. Furthermore, they also impact land surface factors, such as soil moisture and vegetation, which can in turn affect surface water quality, in particular, levels of organic matter in surface waters which are of concern. All of these will be exacerbated by anthropogenic climate change. While some source water quality parameters, particularly Total Organic Carbon (TOC) and bromide concentrations, are not directly regulated for drinking water, these parameters are precursors to the formation of disinfection byproducts (DBPs), which are regulated in drinking water distribution systems. These DBPs form when a disinfectant, added to the water to protect public health against microbial pathogens, most commonly chlorine, reacts with dissolved organic matter (DOM), measured as TOC or dissolved organic carbon (DOC), and inorganic precursor materials, such as bromide. Therefore, understanding and modeling the extremes of TOC and Bromide concentrations is of critical interest for drinking water utilities. In this study we develop nonstationary extreme value analysis models for threshold exceedances of source water quality parameters, specifically TOC and bromide concentrations. In this, the threshold exceedances are modeled as Generalized Pareto Distribution (GPD) whose parameters vary as a function of climate and land surface variables - thus, enabling to capture the temporal nonstationarity. We apply these to model threshold exceedance of source water TOC and bromide concentrations at two locations with different climate and find very good performance.

  1. Eutrophication in the Yunnan Plateau lakes: the influence of lake morphology, watershed land use, and socioeconomic factors.

    PubMed

    Liu, Wenzhi; Li, Siyue; Bu, Hongmei; Zhang, Quanfa; Liu, Guihua

    2012-03-01

    Lakes play an important role in socioeconomic development and ecological balance in China, but their water quality has deteriorated considerably in recent decades. In this study, we investigated the spatial-temporal variations of eutrophication parameters (secchi depth, total nitrogen, total phosphorus, chemical oxygen demand, chlorophyll-a, trophic level index, and trophic state index) and their relationships with lake morphology, watershed land use, and socioeconomic factors in the Yunnan Plateau lakes. Results indicated that about 77.8% of lakes were eutrophic according to trophic state index. The plateau lakes showed spatial variations in water quality and could be classified into high-nutrient and low-nutrient groups. However, because watersheds were dominated by vegetation, all eutrophication parameters except chlorophyll-a showed no significant differences between the wet and dry seasons. Lake depth, water residence time, volume, and percentage of built-up land were significantly related to several eutrophication parameters. Agricultural land use and social-economic factors had no significant correlation with all eutrophication parameters. Stepwise regression analyses demonstrated that lake depth and water residence time accounted for 73.8% to 87.6% of the spatial variation of single water quality variables, respectively. Redundancy analyses indicated that lake morphology, watershed land use, and socioeconomic factors together explained 74.3% of the spatial variation in overall water quality. The results imply that water quality degradation in the plateau lakes may be mainly due to the domestic and industrial wastewaters. This study will improve our understanding of the determinants of lake water quality and help to design efficient strategies for controlling eutrophication in the plateau region.

  2. Development and evaluation of a dimensionless mechanistic pan coating model for the prediction of coated tablet appearance.

    PubMed

    Niblett, Daniel; Porter, Stuart; Reynolds, Gavin; Morgan, Tomos; Greenamoyer, Jennifer; Hach, Ronald; Sido, Stephanie; Karan, Kapish; Gabbott, Ian

    2017-08-07

    A mathematical, mechanistic tablet film-coating model has been developed for pharmaceutical pan coating systems based on the mechanisms of atomisation, tablet bed movement and droplet drying with the main purpose of predicting tablet appearance quality. Two dimensionless quantities were used to characterise the product properties and operating parameters: the dimensionless Spray Flux (relating to area coverage of the spray droplets) and the Niblett Number (relating to the time available for drying of coating droplets). The Niblett Number is the ratio between the time a droplet needs to dry under given thermodynamic conditions and the time available for the droplet while on the surface of the tablet bed. The time available for drying on the tablet bed surface is critical for appearance quality. These two dimensionless quantities were used to select process parameters for a set of 22 coating experiments, performed over a wide range of multivariate process parameters. The dimensionless Regime Map created can be used to visualise the effect of interacting process parameters on overall tablet appearance quality and defects such as picking and logo bridging. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Optimization of dose and image quality in adult and pediatric computed tomography scans

    NASA Astrophysics Data System (ADS)

    Chang, Kwo-Ping; Hsu, Tzu-Kun; Lin, Wei-Ting; Hsu, Wen-Lin

    2017-11-01

    Exploration to maximize CT image and reduce radiation dose was conducted while controlling for multiple factors. The kVp, mAs, and iteration reconstruction (IR), affect the CT image quality and radiation dose absorbed. The optimal protocols (kVp, mAs, IR) are derived by figure of merit (FOM) based on CT image quality (CNR) and CT dose index (CTDIvol). CT image quality metrics such as CT number accuracy, SNR, low contrast materials' CNR and line pair resolution were also analyzed as auxiliary assessments. CT protocols were carried out with an ACR accreditation phantom and a five-year-old pediatric head phantom. The threshold values of the adult CT scan parameters, 100 kVp and 150 mAs, were determined from the CT number test and line pairs in ACR phantom module 1and module 4 respectively. The findings of this study suggest that the optimal scanning parameters for adults be set at 100 kVp and 150-250 mAs. However, for improved low- contrast resolution, 120 kVp and 150-250 mAs are optimal. Optimal settings for pediatric head CT scan were 80 kVp/50 mAs, for maxillary sinus and brain stem, while 80 kVp /300 mAs for temporal bone. SNR is not reliable as the independent image parameter nor the metric for determining optimal CT scan parameters. The iteration reconstruction (IR) approach is strongly recommended for both adult and pediatric CT scanning as it markedly improves image quality without affecting radiation dose.

  4. From in situ coal to the final coal product: A case study of the Danville Coal Member (Indiana)

    USGS Publications Warehouse

    Mastalerz, Maria; Padgett, P.L.

    1999-01-01

    A surface coal mine operation and preparation plant in southwestern Indiana was sampled to examine variations in coal quality and coal petrography parameters for the Danville Coal Member of the Dugger Formation (Pennsylvanian-Desmoinesian, Westphalian D). Representative samples from in situ coal, preparation plant feeds, and a final coal product were collected in order to compare coal quality, coal petrography, trace element concentrations, and ash chemistry of the coal to those of the product. Coal quality parameters of the in situ samples and various feeds, coarse refuse, and final product were variable. The quality of the final coal product was best predicted by the coal quality of the clean coal feed (from the middle portions of the seam). Some trace element contents, especially lead and arsenic, varied between the coal feeds and the product. Lead contents increased in the feeds and product compared to the channel sample of the raw coal, possibly due to contamination in the handling process.A surface coal mine operation and preparation plant in southwestern Indiana was sampled to examine variations in coal quality and coal petrography parameters for the Danville Coal Member of the Dugger Formation (Pennsylvanian-Desmoinesian, Westphalian D). Representative samples from in situ coal, preparation plant feeds, and a final coal product were collected in order to compare coal quality, coal petrography, trace element concentrations, and ash chemistry of the coal to those of the product. Coal quality parameters of the in situ samples and various feeds, coarse refuse, and final product were variable. The quality of the final coal product was best predicted by the coal quality of the clean coal feed (from the middle portions of the seam). Some trace element contents, especially lead and arsenic, varied between the coal feeds and the product. Lead contents increased in the feeds and product compared to the channel sample of the raw coal, possibly due to contamination in the handling process.

  5. Effects of land use and land cover changes on water quality in the uMngeni river catchment, South Africa

    NASA Astrophysics Data System (ADS)

    Namugize, Jean Nepomuscene; Jewitt, Graham; Graham, Mark

    2018-06-01

    Land use and land cover change are major drivers of water quality deterioration in watercourses and impoundments. However, understanding of the spatial and temporal variability of land use change characteristics and their link to water quality parameters in catchments is limited. As a contribution to address this limitation, the objective of this study is to assess the linkages between biophysico-chemical water quality parameters and land use and land cover (LULC) classes in the upper reaches of the uMngeni Catchment, a rapidly developing catchment in South Africa. These were assessed using Geographic Information Systems tools and statistical analyses for the years 1994, 2000, 2008 and 2011 based on changes over time of eight LULC classes and available water quality information. Natural vegetation, forest plantations and cultivated areas occupy 85% of the catchment. Cultivated, urban/built-up and degraded areas increased by 6%, 4.5% and 3%, respectively coinciding with a decrease in natural vegetation by 17%. Variability in the concentration of water quality parameters from 1994 to 2011 and an overall decline in water quality were observed. Escherichia coli (E. coli) levels exceeding the recommended guidelines for recreation and public health protection was noted as a major issue at seven of the nine sampling points. Overall, water supply reservoirs in the catchment retained over 20% of nutrients and over 85% of E. coli entering them. A relationship between land use types and water quality variables was found. However, the degree and magnitude of the associations varies between sub-catchments and is difficult to quantify. This highlights the complexity and the site-specific nature of relationships between land use types and water quality parameters in the catchment. Thus, this study provides useful findings on the general relationship between land use and land cover and water quality degradation, but highlights the risks of applying simple relationships or adding complex relationships in the management of the catchment.

  6. Urban stream syndrome in a small, lightly developed watershed: a statistical analysis of water chemistry parameters, land use patterns, and natural sources.

    PubMed

    Halstead, Judith A; Kliman, Sabrina; Berheide, Catherine White; Chaucer, Alexander; Cock-Esteb, Alicea

    2014-06-01

    The relationships among land use patterns, geology, soil, and major solute concentrations in stream water for eight tributaries of the Kayaderosseras Creek watershed in Saratoga County, NY, were investigated using Pearson correlation coefficients and multivariate regression analysis. Sub-watersheds corresponding to each sampling site were delineated, and land use patterns were determined for each of the eight sub-watersheds using GIS. Four land use categories (urban development, agriculture, forests, and wetlands) constituted more than 99 % of the land in the sub-watersheds. Eleven water chemistry parameters were highly and positively correlated with each other and urban development. Multivariate regression models indicated urban development was the most powerful predictor for the same eleven parameters (conductivity, TN, TP, NO[Formula: see text], Cl(-), HCO(-)3, SO9(2-)4, Na(+), K(+), Ca(2+), and Mg(2+)). Adjusted R(2) values, ranging from 19 to 91 %, indicated that these models explained an average of 64 % of the variance in these 11 parameters across the samples and 70 % when Mg(2+) was omitted. The more common R (2), ranging from 29 to 92 %, averaged 68 % for these 11 parameters and 72 % when Mg(2+) was omitted. Water quality improved most with forest coverage in stream watersheds. The strong associations between water quality variables and urban development indicated an urban source for these 11 water quality parameters at all eight sampling sites was likely, suggesting that urban stream syndrome can be detected even on a relatively small scale in a lightly developed area. Possible urban sources of Ca(2+) and HCO(-)3 are suggested.

  7. Effects and limitations of an AED with audiovisual feedback for cardiopulmonary resuscitation: a randomized manikin study.

    PubMed

    Fischer, Henrik; Gruber, Julia; Neuhold, Stephanie; Frantal, Sophie; Hochbrugger, Eva; Herkner, Harald; Schöchl, Herbert; Steinlechner, Barbara; Greif, Robert

    2011-07-01

    Correctly performed basic life support (BLS) and early defibrillation are the most effective measures to treat sudden cardiac arrest. Audiovisual feedback improves BLS. Automated external defibrillators (AED) with feedback technology may play an important role in improving CPR quality. The aim of this simulation study was to investigate if an AED with audiovisual feedback improves CPR parameters during standard BLS performed by trained laypersons. With ethics committee approval and informed consent, 68 teams (2 flight attendants each) performed 12 min of standard CPR with the AED's audiovisual feedback mechanism enabled or disabled. We recorded CPR quality parameters during resuscitation on a manikin in this open, prospective, randomized controlled trial. Between the feedback and control-group we measured differences in compression depth and rate as main outcome parameters and effective compressions, correct hand position, and incomplete decompression as secondary outcome parameters. An effective compression was defined as a compression with correct depth, hand position, and decompression. The feedback-group delivered compression rates closest to the recommended guidelines (101 ± 9 vs. 109 ± 15/min, p=0.009), more effective compressions (20 ± 18 vs. 5 ± 6%, p<0.001), more compressions with correct hand position (96 ± 13 vs. 88 ± 16%, p<0.001), and less leaning (21 ± 31 vs. 77 ± 33%, p<0.001). However, only the control-group adhered to the recommended compression depth (44 ± 7 mm vs. 39 ± 6, p=0.003). Use of an AED's audiovisual feedback system improved some CPR-quality parameters, thus confirming findings of earlier studies with the notable exception of decreased compression depth, which is a key parameter that might be linked to reduced cardiac output. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  8. The combination of kinetic and flow cytometric semen parameters as a tool to predict fertility in cryopreserved bull semen.

    PubMed

    Gliozzi, T M; Turri, F; Manes, S; Cassinelli, C; Pizzi, F

    2017-11-01

    Within recent years, there has been growing interest in the prediction of bull fertility through in vitro assessment of semen quality. A model for fertility prediction based on early evaluation of semen quality parameters, to exclude sires with potentially low fertility from breeding programs, would therefore be useful. The aim of the present study was to identify the most suitable parameters that would provide reliable prediction of fertility. Frozen semen from 18 Italian Holstein-Friesian proven bulls was analyzed using computer-assisted semen analysis (CASA) (motility and kinetic parameters) and flow cytometry (FCM) (viability, acrosomal integrity, mitochondrial function, lipid peroxidation, plasma membrane stability and DNA integrity). Bulls were divided into two groups (low and high fertility) based on the estimated relative conception rate (ERCR). Significant differences were found between fertility groups for total motility, active cells, straightness, linearity, viability and percentage of DNA fragmented sperm. Correlations were observed between ERCR and some kinetic parameters, and membrane instability and some DNA integrity indicators. In order to define a model with high relation between semen quality parameters and ERCR, backward stepwise multiple regression analysis was applied. Thus, we obtained a prediction model that explained almost half (R 2=0.47, P<0.05) of the variation in the conception rate and included nine variables: five kinetic parameters measured by CASA (total motility, active cells, beat cross frequency, curvilinear velocity and amplitude of lateral head displacement) and four parameters related to DNA integrity evaluated by FCM (degree of chromatin structure abnormality Alpha-T, extent of chromatin structure abnormality (Alpha-T standard deviation), percentage of DNA fragmented sperm and percentage of sperm with high green fluorescence representative of immature cells). A significant relationship (R 2=0.84, P<0.05) was observed between real and predicted fertility. Once the accuracy of fertility prediction has been confirmed, the model developed in the present study could be used by artificial insemination centers for bull selection or for elimination of poor fertility ejaculates.

  9. TestSTORM: Simulator for optimizing sample labeling and image acquisition in localization based super-resolution microscopy

    PubMed Central

    Sinkó, József; Kákonyi, Róbert; Rees, Eric; Metcalf, Daniel; Knight, Alex E.; Kaminski, Clemens F.; Szabó, Gábor; Erdélyi, Miklós

    2014-01-01

    Localization-based super-resolution microscopy image quality depends on several factors such as dye choice and labeling strategy, microscope quality and user-defined parameters such as frame rate and number as well as the image processing algorithm. Experimental optimization of these parameters can be time-consuming and expensive so we present TestSTORM, a simulator that can be used to optimize these steps. TestSTORM users can select from among four different structures with specific patterns, dye and acquisition parameters. Example results are shown and the results of the vesicle pattern are compared with experimental data. Moreover, image stacks can be generated for further evaluation using localization algorithms, offering a tool for further software developments. PMID:24688813

  10. Determining appropriate imaging parameters for kilovoltage intrafraction monitoring: an experimental phantom study

    NASA Astrophysics Data System (ADS)

    Wallace, D.; Ng, J. A.; Keall, P. J.; O'Brien, R. T.; Poulsen, P. R.; Juneja, P.; Booth, J. T.

    2015-06-01

    Kilovoltage intrafraction monitoring (KIM) utilises the kV imager during treatment for real-time tracking of prostate fiducial markers. However, its effectiveness relies on sufficient image quality for the fiducial tracking task. To guide the performance characterisation of KIM under different clinically relevant conditions, the effect of different kV parameters and patient size on image quality, and quantification of MV scatter from the patient to the kV detector panel were investigated in this study. Image quality was determined for a range of kV acquisition frame rates, kV exposure, MV dose rates and patient sizes. Two methods were used to determine image quality; the ratio of kV signal through the patient to the MV scatter from the patient incident on the kilovoltage detector, and the signal-to-noise ratio (SNR). The effect of patient size and frame rate on MV scatter was evaluated in a homogeneous CIRS pelvis phantom and marker segmentation was determined utilising the Rando phantom with embedded markers. MV scatter incident on the detector was shown to be dependent on patient thickness and frame rate. The segmentation code was shown to be successful for all frame rates above 3 Hz for the Rando phantom corresponding to a kV to MV ratio of 0.16 and an SNR of 1.67. For a maximum patient dimension less than 36.4 cm the conservative kV parameters of 5 Hz at 1 mAs can be used to reduce dose while retaining image quality, where the current baseline kV parameters of 10 Hz at 1 mAs is shown to be adequate for marker segmentation up to a patient dimension of 40 cm. In conclusion, the MV scatter component of image quality noise for KIM has been quantified. For most prostate patients, use of KIM with 10 Hz imaging at 1 mAs is adequate however image quality can be maintained and imaging dose reduced by altering existing acquisition parameters.

  11. Effect of methionine supplementation in chicken feed on the quality and shelf life of fresh poultry meat.

    PubMed

    Albrecht, Antonia; Herbert, Ulrike; Miskel, Dennis; Heinemann, Celine; Braun, Carina; Dohlen, Sophia; Zeitz, Johanna O; Eder, Klaus; Saremi, Behnam; Kreyenschmidt, Judith

    2017-08-01

    The aim of this study was to investigate the influence of different methionine sources and concentrations on the quality and spoilage process of broiler meat. The trial was comprised of 7 treatment groups: one basal group (suboptimal in Methionine+Cysteine; i.e., 0.89, 0.74, 0.69% in DM SID Met+Cys in starter, grower, and finisher diets, respectively) and 3 doses (0.10, 0.25, and 0.40%) of either DL-Methionine (DLM) or DL-2-hydroxy-4-methylthio butanoic acid (DL-HMTBA) on an equimolar basis of the DLM-supplemented groups. The broilers were fed the diets for 35 d, then slaughtered and processed. The filets were aerobically packed and stored under temperature controlled conditions at 4°C. Meat quality investigations were comprised of microbial investigations (total viable count and Pseudomonas spp.), pH and drip loss measurements of the filets. The shelf life of the meat samples was determined based on sensory parameters. After slaughtering, all supplemented meat samples showed a high quality, whereby no differences between the 2 methionine sources could be detected for the microbial load, pH, and drip loss. In comparison to the control group, the supplemented samples showed a higher sensory quality, characterized by a fresh smell and fresh red color. Methionine supplementation had a significant influence on meat quality parameters during storage. The microbial load, pH and drip loss of the chicken filets were positively correlated to the methionine concentration. Additionally, the microbial load at the end of storage was positively correlated to pH and drip loss values. Nevertheless, the microbial parameters were in a normal range and the positive correlation to methionine concentration did not affect the sensory shelf life. The mean sensory shelf life of the broiler filets varied between 7 to 9 d. During storage, no difference in the development of sensory parameters was observed between the supplemented groups, while the spoilage process of the basal group occurred slightly faster. In conclusion, methionine concentration, but not methionine source, effected meat quality parameters in breast muscles of broilers. © 2017 Poultry Science Association Inc.

  12. Application of the index WQI-CCME with data aggregation per monitoring campaign and per section of the river: case study-Joanes River, Brazil.

    PubMed

    de Almeida, Geane Silva; de Oliveira, Iara Brandão

    2018-03-07

    This work applied the Water Quality Index developed by the Canadian Council of Ministers of the Environment (WQI-CCME), to communicate the water quality per section of the Joanes River basin, State of Bahia, Brazil. WQI-CCME is a statistical procedure that originally requires the execution of at least four monitoring campaigns per monitoring location and the measurement of at least four parameters. This paper presents a new aggregation method to calculate the WQI-CCME because, to apply the original method in Joanes River, a huge loss of information would occur, by the fact that, the number of analyzed parameters varied between the monitoring campaigns developed by the Government Monitoring Program. This work modified the original aggregation method replacing it by a data aggregation for a single monitoring campaign, in a minimum of four monitoring locations per section of the river and a minimum of four parameters per monitoring location. Comparison between the calculation of WQI-CCME for river sections, with the index, WQI-CETESB, developed by the Brazilian Environmental Sanitation and Technology Company-CETESB, proved the applicability of the new aggregation method. The WQI-CETESB has it bases on the WQI from the National Sanitation Foundation and uses nine fixed parameters. As WQI-CCME uses the totality of the analyzed parameters without restrictions, it is more flexible, and the results seem more adequate to indicate the real river water quality. However, the WQI-CCME has a more stringent water quality scale in comparison with the WQI-CETESB, resulting in inferior water quality information. In conclusion, the WQI-CCME with a new aggregation method is adequate for communicating the water quality at a given time, per section of a river, respecting the minimum number of four analyses and four monitoring points. As a result, without a need to wait for other campaigns, it reduces the cost of a monitoring program and the period to communicate the water quality. The adequacy of the WQI-CCME was similar to the finding of others.

  13. Potential impacts of climate change on water quality in a shallow reservoir in China.

    PubMed

    Zhang, Chen; Lai, Shiyu; Gao, Xueping; Xu, Liping

    2015-10-01

    To study the potential effects of climate change on water quality in a shallow reservoir in China, the field data analysis method is applied to data collected over a given monitoring period. Nine water quality parameters (water temperature, ammonia nitrogen, nitrate nitrogen, nitrite nitrogen, total nitrogen, total phosphorus, chemical oxygen demand, biochemical oxygen demand and dissolved oxygen) and three climate indicators for 20 years (1992-2011) are considered. The annual trends exhibit significant trends with respect to certain water quality and climate parameters. Five parameters exhibit significant seasonality differences in the monthly means between the two decades (1992-2001 and 2002-2011) of the monitoring period. Non-parametric regression of the statistical analyses is performed to explore potential key climate drivers of water quality in the reservoir. The results indicate that seasonal changes in temperature and rainfall may have positive impacts on water quality. However, an extremely cold spring and high wind speed are likely to affect the self-stabilising equilibrium states of the reservoir, which requires attention in the future. The results suggest that land use changes have important impact on nitrogen load. This study provides useful information regarding the potential effects of climate change on water quality in developing countries.

  14. Changes of physicochemical and microbiologicalparameters of infiltration water at Debina intake in Poznan, unique conditions - a flood

    NASA Astrophysics Data System (ADS)

    Kołaska, Sylwia; Jeż-Walkowiak, Joanna; Dymaczewski, Zbysław

    2018-02-01

    The paper presents characteristics of Debina infiltration intake which provides water for Poznan and neighbouring communes. The evaluation of effectiveness of infiltration process has been done based on the quality parameters of river water and infiltration water. The analysed water quality parameters are as follows: temperature, iron, manganese, DOCKMnO4, TOC, turbidity, colour, dissolved oxygen, free carbon dioxide, conductivity, total hardness, carbonate hardness, pH, heavy metals, detergents and microorganisms. The paper also includes an assessment of the impact of flood conditions on the quality of infiltration water and operation of infiltration intake. In this part of the paper the following parameters were taken into account: iron, manganese, DOCKMnO4, TOC, turbidity, colour, dissolved oxygen, free carbon dioxide, conductivity, total hardness, the total number of microorganisms in 36°C (mesophilic), the total number of microorganisms in 22°C (psychrophilic), coli bacteria, Clostridium perfringens, Escherichia coli, Enterococci. Analysis of the effects of flood on infiltration process leads to the following conclusions: the deterioration of infiltration water quality was due to the deterioration of river water quality, substantial shortening of groundwater passage and partial disappearance of the aeration zone. The observed deterioration of infiltration water quality did not affect the treated water quality, produced at water treatment plant.

  15. Prospective, randomized, blinded evaluation of donor semen quality provided by seven commercial sperm banks.

    PubMed

    Carrell, Douglas T; Cartmill, Deborah; Jones, Kirtly P; Hatasaka, Harry H; Peterson, C Matthew

    2002-07-01

    To evaluate variability in donor semen quality between seven commercial donor sperm banks, within sperm banks, and between intracervical insemination and intrauterine insemination. Prospective, randomized, blind evaluation of commercially available donor semen samples. An academic andrology laboratory. Seventy-five cryopreserved donor semen samples were evaluated. Samples were coded, then blindly evaluated for semen quality. Standard semen quality parameters, including concentration, motility parameters, World Health Organization criteria morphology, and strict criteria morphology. Significant differences were observed between donor semen banks for most semen quality parameters analyzed in intracervical insemination samples. In general, the greatest variability observed between banks was in percentage progressive sperm motility (range, 8.8 +/- 5.8 to 42.4 +/- 5.5) and normal sperm morphology (strict criteria; range, 10.1 +/- 3.3 to 26.6 +/- 4.7). Coefficients of variation within sperm banks were generally high. These data demonstrate the variability of donor semen quality provided by commercial sperm banks, both between banks and within a given bank. No relationship was observed between the size or type of sperm bank and the degree of variability. The data demonstrate the lack of uniformity in the criteria used to screen potential semen donors and emphasize the need for more stringent screening criteria and strict quality control in processing samples.

  16. Close-range photogrammetry for aircraft quality control

    NASA Astrophysics Data System (ADS)

    Schwartz, D. S.

    Close range photogrammetry is applicable to quality assurance inspections, design data acquisition, and test management support tasks, yielding significant cost avoidance and increased productivity. An understanding of mensuration parameters and their related accuracies is fundamental to the successful application of industrial close range photogrammetry. Attention is presently given to these parameters and to the use of computer modelling as an aid to the photogrammetric entrepreneur in industry. Suggested improvements to cameras and film readers for industrial applications are discussed.

  17. [Effects of occupational exposure to pesticides on semen quality of workers in an agricultural community of Merida state, Venezuela].

    PubMed

    Miranda-Contreras, Leticia; Cruz, Ibis; Osuna, Jesús A; Gómez-Pérez, Roald; Berrueta, Lisbeth; Salmen, Siham; Colmenares, Melisa; Barreto, Silvio; Balza, Alirio; Morales, Yasmin; Zavala, Leisalba; Labarca, Emilitza; García, Nelly; Sanchez, Beluardi; Contreras, Carlos A; Andrade, Henry

    2015-06-01

    Numerous studies report adverse effects of pesticides on male reproductive health. The objectives of this study were to investigate whether there is a relationship between occupational exposure to pesticides and semen quality, and to determine whether chronic exposure to pesticides differentially affects semen quality in men of different ages. A comparative study of 64 farmers and 64 control men was performed. The farmers were interviewed to determine their occupational history and particularly, activities that may involve exposure to pesticides. Semen parameters were evaluated and a comparative analysis of semen variables between exposed and control groups, as well as between age groups: 18-29, 30-37 and 38-60 years was done. Significant alterations of some semen parameters in the exposed group were found, such as: decreases in sperm concentration, slow progressive motility and sperm membrane integrity; at the same time, increases in eosin Y positive and sperm DNA fragmentation index. The results obtained by age groups showed significant differences between exposed and control groups for the parameters of membrane integrity, eosin Y positive and sperm DNA fragmentation index, being the exposed group between 18-29 years that showed the highest altered cases of these parameters. Our results prove that occupational pesticide exposure is associated with alterations in sperm quality, creating a risk to farm workers in their reproductive capacity.

  18. Surveying drinking water quality (Balikhlou River, Ardabil Province, Iran)

    NASA Astrophysics Data System (ADS)

    Aalipour erdi, Mehdi; Gasempour niari, Hassan; Mousavi Meshkini, Seyyed Reza; Foroug, Somayeh

    2018-03-01

    Considering the importance of Balikhlou River as one of the most important water sources of Ardabil, Nir and Sarein cities, maintaining water quality of this river is the most important goals in provincial and national levels. This river includes a wide area that provides agricultural, industrial and drinking water for the residents. Thus, surveying the quality of this river is important in planning and managing of region. This study examined the quality of river through eight physicochemical parameters (SO4, No3, BOD5, TDS, turbidity, pH, EC, COD) in two high- and low-water seasons by international and national standards in 2013. For this purpose, a review along the river has been done in five stations using t test and SPSS software. Model results showed that the amount difference in TDS and EC with WHO standards, and TDS rates with Iran standards in low-water seasons, pH and EC with WHO standards in high-water seasons, is not significant in high-water season; but for pH and SO4 parameters, turbidity and NO3 in both standards and EC value with WHO standard in low-water season and pH, EC, SO4 parameters and turbidity and NO3 in high-water season have significant difference from 5 to 1%, this shows the ideal limit and lowness of parameters for different usage.

  19. Expected Improvements in the Quantitative Remote Sensing of Optically Complex Waters with the Use of an Optically Fast Hyperspectral Spectrometer—A Modeling Study

    PubMed Central

    Moses, Wesley J.; Bowles, Jeffrey H.; Corson, Michael R.

    2015-01-01

    Using simulated data, we investigated the effect of noise in a spaceborne hyperspectral sensor on the accuracy of the atmospheric correction of at-sensor radiances and the consequent uncertainties in retrieved water quality parameters. Specifically, we investigated the improvement expected as the F-number of the sensor is changed from 3.5, which is the smallest among existing operational spaceborne hyperspectral sensors, to 1.0, which is foreseeable in the near future. With the change in F-number, the uncertainties in the atmospherically corrected reflectance decreased by more than 90% across the visible-near-infrared spectrum, the number of pixels with negative reflectance (caused by over-correction) decreased to almost one-third, and the uncertainties in the retrieved water quality parameters decreased by more than 50% and up to 92%. The analysis was based on the sensor model of the Hyperspectral Imager for the Coastal Ocean (HICO) but using a 30-m spatial resolution instead of HICO’s 96 m. Atmospheric correction was performed using Tafkaa. Water quality parameters were retrieved using a numerical method and a semi-analytical algorithm. The results emphasize the effect of sensor noise on water quality parameter retrieval and the need for sensors with high Signal-to-Noise Ratio for quantitative remote sensing of optically complex waters. PMID:25781507

  20. Evaluation of Indoor Air Quality Screening Strategies: A Step-Wise Approach for IAQ Screening.

    PubMed

    Wong, Ling-Tim; Mui, Kwok-Wai; Tsang, Tsz-Wun

    2016-12-14

    Conducting a full indoor air quality (IAQ) assessment in air-conditioned offices requires large-scale material and manpower resources. However, an IAQ index can be adopted as a handy screening tool to identify any premises (with poor IAQ) that need more comprehensive IAQ assessments to prioritize IAQ improvements. This study proposes a step-wise IAQ screening protocol to facilitate its cost-effective management among building owners and managers. The effectiveness of three IAQ indices, namely θ₁ (with one parameter: CO₂), θ₂ (with two parameters: CO₂ and respirable suspended particulates, RSP) and θ₃ (with three parameters: CO₂, RSP, and total volatile organic compounds, TVOC) are evaluated. Compared in a pairwise manner with respect to the minimum satisfaction levels as stated in the IAQ Certification Scheme by the Hong Kong Environmental Protection Department, the results show that a screening test with more surrogate IAQ parameters is good at identifying both lower and higher risk groups for unsatisfactory IAQ, and thus offers higher resolution. Through the sensitivity and specificity for identifying IAQ problems, the effectiveness of alternative IAQ screening methods with different monitoring parameters is also reported.

  1. Evaluation of Indoor Air Quality Screening Strategies: A Step-Wise Approach for IAQ Screening

    PubMed Central

    Wong, Ling-tim; Mui, Kwok-wai; Tsang, Tsz-wun

    2016-01-01

    Conducting a full indoor air quality (IAQ) assessment in air-conditioned offices requires large-scale material and manpower resources. However, an IAQ index can be adopted as a handy screening tool to identify any premises (with poor IAQ) that need more comprehensive IAQ assessments to prioritize IAQ improvements. This study proposes a step-wise IAQ screening protocol to facilitate its cost-effective management among building owners and managers. The effectiveness of three IAQ indices, namely θ1 (with one parameter: CO2), θ2 (with two parameters: CO2 and respirable suspended particulates, RSP) and θ3 (with three parameters: CO2, RSP, and total volatile organic compounds, TVOC) are evaluated. Compared in a pairwise manner with respect to the minimum satisfaction levels as stated in the IAQ Certification Scheme by the Hong Kong Environmental Protection Department, the results show that a screening test with more surrogate IAQ parameters is good at identifying both lower and higher risk groups for unsatisfactory IAQ, and thus offers higher resolution. Through the sensitivity and specificity for identifying IAQ problems, the effectiveness of alternative IAQ screening methods with different monitoring parameters is also reported. PMID:27983667

  2. Botanical discrimination of Greek unifloral honeys with physico-chemical and chemometric analyses.

    PubMed

    Karabagias, Ioannis K; Badeka, Anastasia V; Kontakos, Stavros; Karabournioti, Sofia; Kontominas, Michael G

    2014-12-15

    The aim of the present study was to investigate the possibility of characterisation and classification of Greek unifloral honeys (pine, thyme, fir and orange blossom) according to botanical origin using volatile compounds, conventional physico-chemical parameters and chemometric analyses (MANOVA and Linear Discriminant Analysis). For this purpose, 119 honey samples were collected during the harvesting period 2011 from 14 different regions in Greece known to produce unifloral honey of good quality. Physico-chemical analysis included the identification and semi quantification of fifty five volatile compounds performed by Headspace Solid Phase Microextraction coupled to gas chromatography/mass spectroscopy and the determination of conventional quality parameters such as pH, free, lactonic, total acidity, electrical conductivity, moisture, ash, lactonic/free acidity ratio and colour parameters L, a, b. Results showed that using 40 diverse variables (30 volatile compounds of different classes and 10 physico-chemical parameters) the honey samples were satisfactorily classified according to botanical origin using volatile compounds (84.0% correct prediction), physicochemical parameters (97.5% correct prediction), and the combination of both (95.8% correct prediction) indicating that multi element analysis comprises a powerful tool for honey discrimination purposes. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Gaussian beam profile shaping apparatus, method therefor and evaluation thereof

    DOEpatents

    Dickey, Fred M.; Holswade, Scott C.; Romero, Louis A.

    1999-01-01

    A method and apparatus maps a Gaussian beam into a beam with a uniform irradiance profile by exploiting the Fourier transform properties of lenses. A phase element imparts a design phase onto an input beam and the output optical field from a lens is then the Fourier transform of the input beam and the phase function from the phase element. The phase element is selected in accordance with a dimensionless parameter which is dependent upon the radius of the incoming beam, the desired spot shape, the focal length of the lens and the wavelength of the input beam. This dimensionless parameter can also be used to evaluate the quality of a system. In order to control the radius of the incoming beam, optics such as a telescope can be employed. The size of the target spot and the focal length can be altered by exchanging the transform lens, but the dimensionless parameter will remain the same. The quality of the system, and hence the value of the dimensionless parameter, can be altered by exchanging the phase element. The dimensionless parameter provides design guidance, system evaluation, and indication as to how to improve a given system.

  4. Gaussian beam profile shaping apparatus, method therefore and evaluation thereof

    DOEpatents

    Dickey, F.M.; Holswade, S.C.; Romero, L.A.

    1999-01-26

    A method and apparatus maps a Gaussian beam into a beam with a uniform irradiance profile by exploiting the Fourier transform properties of lenses. A phase element imparts a design phase onto an input beam and the output optical field from a lens is then the Fourier transform of the input beam and the phase function from the phase element. The phase element is selected in accordance with a dimensionless parameter which is dependent upon the radius of the incoming beam, the desired spot shape, the focal length of the lens and the wavelength of the input beam. This dimensionless parameter can also be used to evaluate the quality of a system. In order to control the radius of the incoming beam, optics such as a telescope can be employed. The size of the target spot and the focal length can be altered by exchanging the transform lens, but the dimensionless parameter will remain the same. The quality of the system, and hence the value of the dimensionless parameter, can be altered by exchanging the phase element. The dimensionless parameter provides design guidance, system evaluation, and indication as to how to improve a given system. 27 figs.

  5. Estimating system parameters for solvent-water and plant cuticle-water using quantum chemically estimated Abraham solute parameters.

    PubMed

    Liang, Yuzhen; Torralba-Sanchez, Tifany L; Di Toro, Dominic M

    2018-04-18

    Polyparameter Linear Free Energy Relationships (pp-LFERs) using Abraham system parameters have many useful applications. However, developing the Abraham system parameters depends on the availability and quality of the Abraham solute parameters. Using Quantum Chemically estimated Abraham solute Parameters (QCAP) is shown to produce pp-LFERs that have lower root mean square errors (RMSEs) of predictions for solvent-water partition coefficients than parameters that are estimated using other presently available methods. pp-LFERs system parameters are estimated for solvent-water, plant cuticle-water systems, and for novel compounds using QCAP solute parameters and experimental partition coefficients. Refitting the system parameter improves the calculation accuracy and eliminates the bias. Refitted models for solvent-water partition coefficients using QCAP solute parameters give better results (RMSE = 0.278 to 0.506 log units for 24 systems) than those based on ABSOLV (0.326 to 0.618) and QSPR (0.294 to 0.700) solute parameters. For munition constituents and munition-like compounds not included in the calibration of the refitted model, QCAP solute parameters produce pp-LFER models with much lower RMSEs for solvent-water partition coefficients (RMSE = 0.734 and 0.664 for original and refitted model, respectively) than ABSOLV (4.46 and 5.98) and QSPR (2.838 and 2.723). Refitting plant cuticle-water pp-LFER including munition constituents using QCAP solute parameters also results in lower RMSE (RMSE = 0.386) than that using ABSOLV (0.778) and QSPR (0.512) solute parameters. Therefore, for fitting a model in situations for which experimental data exist and system parameters can be re-estimated, or for which system parameters do not exist and need to be developed, QCAP is the quantum chemical method of choice.

  6. Drilling force and temperature of bone under dry and physiological drilling conditions

    NASA Astrophysics Data System (ADS)

    Xu, Linlin; Wang, Chengyong; Jiang, Min; He, Huiyu; Song, Yuexian; Chen, Hanyuan; Shen, Jingnan; Zhang, Jiayong

    2014-11-01

    Many researches on drilling force and temperature have been done with the aim to reduce the labour intensiveness of surgery, avoid unnecessary damage and improve drilling quality. However, there has not been a systematic study of mid- and high-speed drilling under dry and physiological conditions(injection of saline). Furthermore, there is no consensus on optimal drilling parameters. To study these parameters under dry and physiological drilling conditions, pig humerus bones are drilled with medical twist drills operated using a wide range of drilling speeds and feed rates. Drilling force and temperature are measured using a YDZ-II01W dynamometer and a NEC TVS-500EX thermal infrared imager, respectively, to evaluate internal bone damage. To evaluate drilling quality, bone debris and hole morphology are observed by SEM(scanning electron microscopy). Changes in drilling force and temperature give similar results during drilling such that the value of each parameter peaks just before the drill penetrates through the osteon of the compact bone into the trabeculae of the spongy bone. Drilling temperatures under physiological conditions are much lower than those observed under dry conditions, while a larger drilling force occurs under physiological conditions than dry conditions. Drilling speed and feed rate have a significant influence on drilling force, temperature, bone debris and hole morphology. The investigation of the effect of drilling force and temperature on internal bone damage reveals that a drilling speed of 4500 r/min and a feed rate of 50 mm/min are recommended for bone drilling under physiological conditions. Drilling quality peaks under these optimal parameter conditions. This paper proposes the optimal drilling parameters under mid- and high-speed surgical drilling, considering internal bone damage and drilling quality, which can be looked as a reference for surgeons performing orthopedic operations.

  7. Heart Rate Variability Reflects the Natural History of Physiological Development in Healthy Children and Is Not Associated with Quality of Life

    PubMed Central

    Seifert, Georg; Calaminus, Gabriele; Wiener, Andreas; Cysarz, Dirk

    2014-01-01

    Background Quality of life (QoL), being the sum expression of diverse influencing factors, is not easy to determine. A clinically relevant option would be to identify and measure quality of life on the basis of physiological parameters which correlate plausibly and statistically with psychometrically measured QoL. Analysis of heart rate variability (HRV) offers readily measurable physiological parameters which could be of use here. A correlation of HRV with both course of disease and QoL has been reported in patients with chronic illness. Various psychometric instruments have been developed for use in paediatric oncology. The aim of this study was to obtain data on HRV and QoL and their correlations, initially in healthy children. Methods Holter ECG and quality of life were examined in 160 children and adolescents (72 male) aged between 8 and 18 years. QoL was determined with the established questionnaire PEDQoL. Standard parameters of HRV from the frequency domain were calculated and correlated with QoL domains using Spearman (nonparametric) correlation analysis. Results Minor but significant associations were revealed only with regard to the PEDQoL domain “autonomy” on the one hand and heart rate and HRV (e.g. MRR, MRRn, MRRd, HRV_ULF, SDNN) parameters which evidently reflect distinct physiological functions on the other. Conclusions In healthy children and adolescents we have a first indication that there is a correlation between parameters of HRV and QoL. However, to a greater extent, HRV reflects associated physiological processes of the autonomic nervous system. A higher correlation is more likely to be found in chronically ill children. PMID:24625571

  8. Plantar pressure measurements and running-related injury: A systematic review of methods and possible associations.

    PubMed

    Mann, Robert; Malisoux, Laurent; Urhausen, Axel; Meijer, Kenneth; Theisen, Daniel

    2016-06-01

    Pressure-sensitive measuring devices have been identified as appropriate tools for measuring an array of parameters during running. It is unclear which biomechanical characteristics relate to running-related injury (RRI) and which data-processing techniques are most promising to detect this relationship. This systematic review aims to identify pertinent methodologies and characteristics measured using plantar pressure devices, and to summarise their associations with RRI. PubMed, Embase, CINAHL, ScienceDirect and Scopus were searched up until March 2015. Retrospective and prospective, biomechanical studies on running using any kind of pressure-sensitive device with RRI as an outcome were included. All studies involving regular or recreational runners were considered. The study quality was assessed and the measured parameters were summarised. One low quality, two moderate quality and five high quality studies were included. Five different subdivisions of plantar area were identified, as well as five instants and four phases of measurement during foot-ground contact. Overall many parameters were collated and subdivided as plantar pressure and force, plantar pressure and force location, contact area, timing and stride parameters. Differences between the injured and control group were found for mediolateral and anteroposterior displacement of force, contact area, velocity of force displacement, relative force-time integral, mediolateral force ratio, time to peak force and inter-stride correlative patterns. However, no consistent results were found between studies and no biomechanical risk patterns were apparent. Additionally, conflicting findings were reported for peak force in three studies. Based on these observations, we provide suggestions for improved methodology measurement of pertinent parameters for future studies. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  9. Evaluation of milk powder quality by protein oxidative modifications.

    PubMed

    Scheidegger, Dana; Radici, Paola M; Vergara-Roig, Víctor A; Bosio, Noelia S; Pesce, Silvia F; Pecora, Rolando P; Romano, José C P; Kivatinitz, Silvia C

    2013-06-01

    The objective of the present research was to evaluate commercially available milk powders according to their protein oxidative modifications and antioxidant capacity, and to evaluate if these characteristics are related to physical quality parameters such as dispersibility or stability during storage. Fifteen commercially processed spray-dried milk powders were evaluated: 6 whole milk powders (WMP), 4 skim milk powders (SMP), and 5 infant formula powders (IFP). Protein oxidative status was measured as protein carbonyl (PC) content, dityrosine content, and extent of protein polymerization. The level of PC was slightly lower in SMP than in WMP, whereas IFP had more than twice as much PC as WMP (2.8 ± 0.4, 2.1 ± 0.2, and 6.5 ± 1.3 nmol/mg of protein for WMP, SMP, and IFP, respectively). No differences were detected in dityrosine accumulation. Although all the possible pairs of parameters were tested for correlations, we found that 4 parameters were linked: PC, whey content, protein aggregate level, and dispersibility. After 9 mo of storage at -20°C or room temperature, all milk samples were analyzed to evaluate changes in protein oxidative status (PC, dityrosine, and protein integrity) and related parameters. Compared with the initial condition, PC increased in all tested samples after 9 mo of storage at -20°C or at room temperature. Stored milk powders had increased PC and decreased dispersibility compared with prestorage levels. Our results highlight the importance of protein oxidative status in milk powder and its relationship to other related quality parameters, such as protein integrity and dispersibility. Our findings suggest that the understanding of such relationships could help in developing quality differentiation for different types of milk powders in the product market. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  10. Characterization of Italian honeys (Marche Region) on the basis of their mineral content and some typical quality parameters

    PubMed Central

    Conti, Marcelo Enrique; Stripeikis, Jorge; Campanella, Luigi; Cucina, Domenico; Tudino, Mabel Beatriz

    2007-01-01

    Background The characterization of three types of Marche (Italy) honeys (Acacia, Multifloral, Honeydew) was carried out on the basis of the their quality parameters (pH, sugar content, humidity) and mineral content (Na, K, Ca, Mg, Cu, Fe, and Mn). Pattern recognition methods such as principal components analysis (PCA) and linear discriminant analysis (LDA) were performed in order to classify honey samples whose botanical origins were different, and identify the most discriminant parameters. Lastly, using ANOVA and correlations for all parameters, significant differences between diverse types of honey were examined. Results Most of the samples' water content showed good maturity (98%) whilst pH values were in the range 3.50 – 4.21 confirming the good quality of the honeys analysed. Potassium was quantitatively the most relevant mineral (mean = 643 ppm), accounting for 79% of the total mineral content. The Ca, Na and Mg contents account for 14, 3 and 3% of the total mineral content respectively, while other minerals (Cu, Mn, Fe) were present at very low levels. PCA explained 75% or more of the variance with the first two PC variables. The variables with higher discrimination power according to the multivariate statistical procedure were Mg and pH. On the other hand, all samples of acacia and honeydew, and more than 90% of samples of multifloral type have been correctly classified using the LDA. ANOVA shows significant differences between diverse floral origins for all variables except sugar, moisture and Fe. Conclusion In general, the analytical results obtained for the Marche honeys indicate the products' high quality. The determination of physicochemical parameters and mineral content in combination with modern statistical techniques can be a useful tool for honey classification. PMID:17880749

  11. Physicochemical parameters affecting the perception of borehole water quality in Ghana.

    PubMed

    Kulinkina, Alexandra V; Plummer, Jeanine D; Chui, Kenneth K H; Kosinski, Karen C; Adomako-Adjei, Theodora; Egorov, Andrey I; Naumova, Elena N

    2017-08-01

    Rural Ghanaian communities continue using microbiologically contaminated surface water sources due in part to undesirable organoleptic characteristics of groundwater from boreholes. Our objective was to identify thresholds of physical and chemical parameters associated with consumer complaints related to groundwater. Water samples from 94 boreholes in the dry season and 68 boreholes in the rainy season were analyzed for 18 parameters. Interviews of consumers were conducted at each borehole regarding five commonly expressed water quality problems (salty taste, presence of particles, unfavorable scent, oily sheen formation on the water surface, and staining of starchy foods during cooking). Threshold levels of water quality parameters predictive of complaints were determined using the Youden index maximizing the sum of sensitivity and specificity. The probability of complaints at various parameter concentrations was estimated using logistic regression. Exceedances of WHO guidelines were detected for pH, turbidity, chloride, iron, and manganese. Concentrations of total dissolved solids (TDS) above 172mg/L were associated with salty taste complaints. Although the WHO guideline is 1000mg/L, even at half the guideline, the likelihood of salty taste complaint was 75%. Iron concentrations above 0.11, 0.14 and 0.43mg/L (WHO guideline value 0.3mg/L) were associated with complaints of unfavorable scent, oily sheen, and food staining, respectively. Iron and TDS concentrations exhibited strong spatial clustering associated with specific geological formations. Improved groundwater sources in rural African communities that technically meet WHO water quality guidelines may be underutilized in preference of unimproved sources for drinking and domestic uses, compromising human health and sustainability of improved water infrastructure. Copyright © 2017 Elsevier GmbH. All rights reserved.

  12. Cervicothoracic Lordosis Can Influence Outcome After Posterior Cervical Spine Surgery.

    PubMed

    Brasil, Albert Vincent Berthier; Fruett da Costa, Pablo Ramon; Vial, Antonio Delacy Martini; Barcellos, Gabriel da Costa; Zauk, Eduardo Balverdu; Worm, Paulo Valdeci; Ferreira, Marcelo Paglioli; Ferreira, Nelson Pires

    2018-01-01

    Previous studies on the correlation between cervical sagittal balance with improvement in quality of life showed significant results only for parameters of the anterior translation of the cervical spine (such as C2-C7 SVA). We test whether a new parameter, cervicothoracic lordosis , can predict clinical success in this type of surgery. The focused group involved patients who underwent surgical treatment of cervical degenerative disk disease by the posterior approach, due to myelopathy, radiculopathy or a combination of both. Neurologic deficit was measured before and after surgery with the Nurick Scale, postoperative quality of life, physical and mental components of SF-36 and NDI. Cervicothoracic lordosis and various sagittal balance parameters were also measured. Cervicothoracic lordosis was defined as the angle between: a) the line between the centroid of C2 and the centroid of C7; b) the line between the centroid of C7 and the centroid of T6. Correlations between postoperative quality of life and sagittal parameters were calculated. Twenty-nine patients between 27 and 78 years old were evaluated. Surgery types were simple decompression (laminectomy or laminoforaminotomy) (3 patients), laminoplasty (4 patients) and laminectomy with fusion in 22 patients. Significant correlations were found for C2-C7 SVA and cervicothoracic lordosis. C2-C7 SVA correlated negatively with MCS (r=-0.445, p=0.026) and PCS (r=-0.405, p=0.045). Cervicothoracic lordosis correlated positively with MCS (r=0.554, p= 0.004) and PCS (r=0.462, p=0.020) and negatively with NDI (r=-0.416, p=0.031). The parameter cervicothoracic lordosis correlates with improvement of quality life after surgery for cervical degenerative disk disease by the posterior approach.

  13. Improving the quality of parameter estimates obtained from slug tests

    USGS Publications Warehouse

    Butler, J.J.; McElwee, C.D.; Liu, W.

    1996-01-01

    The slug test is one of the most commonly used field methods for obtaining in situ estimates of hydraulic conductivity. Despite its prevalence, this method has received criticism from many quarters in the ground-water community. This criticism emphasizes the poor quality of the estimated parameters, a condition that is primarily a product of the somewhat casual approach that is often employed in slug tests. Recently, the Kansas Geological Survey (KGS) has pursued research directed it improving methods for the performance and analysis of slug tests. Based on extensive theoretical and field research, a series of guidelines have been proposed that should enable the quality of parameter estimates to be improved. The most significant of these guidelines are: (1) three or more slug tests should be performed at each well during a given test period; (2) two or more different initial displacements (Ho) should be used at each well during a test period; (3) the method used to initiate a test should enable the slug to be introduced in a near-instantaneous manner and should allow a good estimate of Ho to be obtained; (4) data-acquisition equipment that enables a large quantity of high quality data to be collected should be employed; (5) if an estimate of the storage parameter is needed, an observation well other than the test well should be employed; (6) the method chosen for analysis of the slug-test data should be appropriate for site conditions; (7) use of pre- and post-analysis plots should be an integral component of the analysis procedure, and (8) appropriate well construction parameters should be employed. Data from slug tests performed at a number of KGS field sites demonstrate the importance of these guidelines.

  14. Effect of simultaneous infrared dry-blanching and dehydration on quality characteristics of carrot slices

    USDA-ARS?s Scientific Manuscript database

    This study investigated the effects of various processing parameters on carrot slices exposed to infrared (IR) radiation heating for achieving simultaneous infrared dry-blanching and dehydration (SIRDBD). The investigated parameters were product surface temperature, slice thickness and processing ti...

  15. Development of optimization model for sputtering process parameter based on gravitational search algorithm

    NASA Astrophysics Data System (ADS)

    Norlina, M. S.; Diyana, M. S. Nor; Mazidah, P.; Rusop, M.

    2016-07-01

    In the RF magnetron sputtering process, the desirable layer properties are largely influenced by the process parameters and conditions. If the quality of the thin film has not reached up to its intended level, the experiments have to be repeated until the desirable quality has been met. This research is proposing Gravitational Search Algorithm (GSA) as the optimization model to reduce the time and cost to be spent in the thin film fabrication. The optimization model's engine has been developed using Java. The model is developed based on GSA concept, which is inspired by the Newtonian laws of gravity and motion. In this research, the model is expected to optimize four deposition parameters which are RF power, deposition time, oxygen flow rate and substrate temperature. The results have turned out to be promising and it could be concluded that the performance of the model is satisfying in this parameter optimization problem. Future work could compare GSA with other nature based algorithms and test them with various set of data.

  16. Influence of cutting data on surface quality when machining 17-4 PH stainless steel

    NASA Astrophysics Data System (ADS)

    Popovici, T. D.; Dijmărescu, M. R.

    2017-08-01

    The aim of the research presented in this paper is to analyse the cutting data influence upon surface quality for 17-4 PH stainless steel milling machining. The cutting regime parameters considered for the experiments were established using cutting regimes from experimental researches or from industrial conditions as basis, within the recommended ranges. The experimental program structure was determined by taking into account compatibility and orthogonality conditions, minimal use of material and labour. The machined surface roughness was determined by measuring the Ra roughness parameter, followed by surface profile registration in the form of graphics which were saved on a computer with MarSurf PS1Explorer software. Based on Ra roughness parameter, maximum values were extracted from these graphics and the influence charts of the cutting regime parameters upon surface roughness were traced using Microsoft Excel software. After a thorough analysis of the resulting data, relevant conclusions were drawn, presenting the interdependence between the surface roughness of the machined 17-4 PH samples and the cutting data variation.

  17. A Model of Regularization Parameter Determination in Low-Dose X-Ray CT Reconstruction Based on Dictionary Learning.

    PubMed

    Zhang, Cheng; Zhang, Tao; Zheng, Jian; Li, Ming; Lu, Yanfei; You, Jiali; Guan, Yihui

    2015-01-01

    In recent years, X-ray computed tomography (CT) is becoming widely used to reveal patient's anatomical information. However, the side effect of radiation, relating to genetic or cancerous diseases, has caused great public concern. The problem is how to minimize radiation dose significantly while maintaining image quality. As a practical application of compressed sensing theory, one category of methods takes total variation (TV) minimization as the sparse constraint, which makes it possible and effective to get a reconstruction image of high quality in the undersampling situation. On the other hand, a preliminary attempt of low-dose CT reconstruction based on dictionary learning seems to be another effective choice. But some critical parameters, such as the regularization parameter, cannot be determined by detecting datasets. In this paper, we propose a reweighted objective function that contributes to a numerical calculation model of the regularization parameter. A number of experiments demonstrate that this strategy performs well with better reconstruction images and saving of a large amount of time.

  18. Aircraft ride quality controller design using new robust root clustering theory for linear uncertain systems

    NASA Technical Reports Server (NTRS)

    Yedavalli, R. K.

    1992-01-01

    The aspect of controller design for improving the ride quality of aircraft in terms of damping ratio and natural frequency specifications on the short period dynamics is addressed. The controller is designed to be robust with respect to uncertainties in the real parameters of the control design model such as uncertainties in the dimensional stability derivatives, imperfections in actuator/sensor locations and possibly variations in flight conditions, etc. The design is based on a new robust root clustering theory developed by the author by extending the nominal root clustering theory of Gutman and Jury to perturbed matrices. The proposed methodology allows to get an explicit relationship between the parameters of the root clustering region and the uncertainty radius of the parameter space. The current literature available for robust stability becomes a special case of this unified theory. The bounds derived on the parameter perturbation for robust root clustering are then used in selecting the robust controller.

  19. Effect of medical and surgical interventions on health-related quality of life in Parkinson's disease.

    PubMed

    Martinez-Martin, Pablo; Deuschl, Günther

    2007-04-30

    Motor-related parameters are the standard outcome parameters for treatment interventions. Nonetheless, subjective appraisals about the consequences of treatment on health-related quality of life (HRQoL) are meanwhile established and may uncover important aspects of interventions. We have reviewed the literature with a defined search strategy and collected 61 clinical trials, which have used HRQoL as a planned outcome parameter. The articles were rated similarly as for the Task Force report of the Movement Disorder Society on interventions for Parkinson's disease (PD), but the relevant outcome parameter was HRQoL. We found that unilateral pallidotomy, deep brain stimulation of the subthalamic nucleus, and rasagiline are efficacious to improve the HRQoL of PD patients. For many other interventions, the efficacy to improve HRQoL in the PD setting cannot be considered to be proven so far. HRQoL should be part of future trial designs and more research is necessary to understand the determinants of QoL in PD.

  20. Direct Metal Deposition of H13 Tool Steel on Copper Alloy Substrate: Parametric Investigation

    NASA Astrophysics Data System (ADS)

    Imran, M. Khalid; Masood, S. H.; Brandt, Milan

    2015-12-01

    Over the past decade, researchers have demonstrated interest in tribology and prototyping by the laser aided material deposition process. Laser aided direct metal deposition (DMD) enables the formation of a uniform clad by melting the powder to form desired component from metal powder materials. In this research H13 tool steel has been used to clad on a copper alloy substrate using DMD. The effects of laser parameters on the quality of DMD deposited clad have been investigated and acceptable processing parameters have been determined largely through trial-and-error approaches. The relationships between DMD process parameters and the product characteristics such as porosity, micro-cracks and microhardness have been analysed using scanning electron microscope (SEM), image analysis software (ImageJ) and microhardness tester. It has been found that DMD parameters such as laser power, powder mass flow rate, feed rate and focus size have an important role in clad quality and crack formation.

  1. Visible and near infrared spectroscopy coupled to random forest to quantify some soil quality parameters

    NASA Astrophysics Data System (ADS)

    de Santana, Felipe Bachion; de Souza, André Marcelo; Poppi, Ronei Jesus

    2018-02-01

    This study evaluates the use of visible and near infrared spectroscopy (Vis-NIRS) combined with multivariate regression based on random forest to quantify some quality soil parameters. The parameters analyzed were soil cation exchange capacity (CEC), sum of exchange bases (SB), organic matter (OM), clay and sand present in the soils of several regions of Brazil. Current methods for evaluating these parameters are laborious, timely and require various wet analytical methods that are not adequate for use in precision agriculture, where faster and automatic responses are required. The random forest regression models were statistically better than PLS regression models for CEC, OM, clay and sand, demonstrating resistance to overfitting, attenuating the effect of outlier samples and indicating the most important variables for the model. The methodology demonstrates the potential of the Vis-NIR as an alternative for determination of CEC, SB, OM, sand and clay, making possible to develop a fast and automatic analytical procedure.

  2. Urinary inorganic arsenic concentrations and semen quality of male partners of subfertile couples in Tokyo.

    PubMed

    Oguri, Tomoko; Yoshinaga, Jun; Toshima, Hiroki; Mizumoto, Yoshifumi; Hatakeyama, Shota; Tokuoka, Susumu

    2016-01-01

    Inorganic arsenic (iAs) has been known as a testicular toxicant in experimental rodents. Possible association between iAs exposure and semen quality (semen volume, sperm concentration, and sperm motility) was explored in male partners of couples (n = 42) who visited a gynecology clinic in Tokyo for infertility consultation. Semen parameters were measured according to WHO guideline at the clinic, and urinary iAs and methylarsonic acid (MMA), and dimethylarsinic acid concentrations were determined by liquid chromatography-hydride generation-ICP mass spectrometry. Biological attributes, dietary habits, and exposure levels to other chemicals with known effects on semen parameters were taken into consideration as covariates. Multiple regression analyses and logistic regression analyses did not find iAs exposure as significant contributor to semen parameters. Lower exposure level of subjects (estimated to be 0.5 μg kg(-1) day(-1)) was considered a reason of the absence of adverse effects on semen parameters, which were seen in rodents dosed with 4-7.5 mg kg(-1).

  3. Genome-Wide QTL Mapping for Wheat Processing Quality Parameters in a Gaocheng 8901/Zhoumai 16 Recombinant Inbred Line Population.

    PubMed

    Jin, Hui; Wen, Weie; Liu, Jindong; Zhai, Shengnan; Zhang, Yan; Yan, Jun; Liu, Zhiyong; Xia, Xianchun; He, Zhonghu

    2016-01-01

    Dough rheological and starch pasting properties play an important role in determining processing quality in bread wheat (Triticum aestivum L.). In the present study, a recombinant inbred line (RIL) population derived from a Gaocheng 8901/Zhoumai 16 cross grown in three environments was used to identify quantitative trait loci (QTLs) for dough rheological and starch pasting properties evaluated by Mixograph, Rapid Visco-Analyzer (RVA), and Mixolab parameters using the wheat 90 and 660 K single nucleotide polymorphism (SNP) chip assays. A high-density linkage map constructed with 46,961 polymorphic SNP markers from the wheat 90 and 660 K SNP assays spanned a total length of 4121 cM, with an average chromosome length of 196.2 cM and marker density of 0.09 cM/marker; 6596 new SNP markers were anchored to the bread wheat linkage map, with 1046 and 5550 markers from the 90 and 660 K SNP assays, respectively. Composite interval mapping identified 119 additive QTLs on 20 chromosomes except 4D; among them, 15 accounted for more than 10% of the phenotypic variation across two or three environments. Twelve QTLs for Mixograph parameters, 17 for RVA parameters and 55 for Mixolab parameters were new. Eleven QTL clusters were identified. The closely linked SNP markers can be used in marker-assisted wheat breeding in combination with the Kompetitive Allele Specific PCR (KASP) technique for improvement of processing quality in bread wheat.

  4. Genome-Wide QTL Mapping for Wheat Processing Quality Parameters in a Gaocheng 8901/Zhoumai 16 Recombinant Inbred Line Population

    PubMed Central

    Jin, Hui; Wen, Weie; Liu, Jindong; Zhai, Shengnan; Zhang, Yan; Yan, Jun; Liu, Zhiyong; Xia, Xianchun; He, Zhonghu

    2016-01-01

    Dough rheological and starch pasting properties play an important role in determining processing quality in bread wheat (Triticum aestivum L.). In the present study, a recombinant inbred line (RIL) population derived from a Gaocheng 8901/Zhoumai 16 cross grown in three environments was used to identify quantitative trait loci (QTLs) for dough rheological and starch pasting properties evaluated by Mixograph, Rapid Visco-Analyzer (RVA), and Mixolab parameters using the wheat 90 and 660 K single nucleotide polymorphism (SNP) chip assays. A high-density linkage map constructed with 46,961 polymorphic SNP markers from the wheat 90 and 660 K SNP assays spanned a total length of 4121 cM, with an average chromosome length of 196.2 cM and marker density of 0.09 cM/marker; 6596 new SNP markers were anchored to the bread wheat linkage map, with 1046 and 5550 markers from the 90 and 660 K SNP assays, respectively. Composite interval mapping identified 119 additive QTLs on 20 chromosomes except 4D; among them, 15 accounted for more than 10% of the phenotypic variation across two or three environments. Twelve QTLs for Mixograph parameters, 17 for RVA parameters and 55 for Mixolab parameters were new. Eleven QTL clusters were identified. The closely linked SNP markers can be used in marker-assisted wheat breeding in combination with the Kompetitive Allele Specific PCR (KASP) technique for improvement of processing quality in bread wheat. PMID:27486464

  5. Optimization of process parameters in drilling of fibre hybrid composite using Taguchi and grey relational analysis

    NASA Astrophysics Data System (ADS)

    Vijaya Ramnath, B.; Sharavanan, S.; Jeykrishnan, J.

    2017-03-01

    Nowadays quality plays a vital role in all the products. Hence, the development in manufacturing process focuses on the fabrication of composite with high dimensional accuracy and also incurring low manufacturing cost. In this work, an investigation on machining parameters has been performed on jute-flax hybrid composite. Here, the two important responses characteristics like surface roughness and material removal rate are optimized by employing 3 machining input parameters. The input variables considered are drill bit diameter, spindle speed and feed rate. Machining is done on CNC vertical drilling machine at different levels of drilling parameters. Taguchi’s L16 orthogonal array is used for optimizing individual tool parameters. Analysis Of Variance is used to find the significance of individual parameters. The simultaneous optimization of the process parameters is done by grey relational analysis. The results of this investigation shows that, spindle speed and drill bit diameter have most effect on material removal rate and surface roughness followed by feed rate.

  6. Determining the accuracy of maximum likelihood parameter estimates with colored residuals

    NASA Technical Reports Server (NTRS)

    Morelli, Eugene A.; Klein, Vladislav

    1994-01-01

    An important part of building high fidelity mathematical models based on measured data is calculating the accuracy associated with statistical estimates of the model parameters. Indeed, without some idea of the accuracy of parameter estimates, the estimates themselves have limited value. In this work, an expression based on theoretical analysis was developed to properly compute parameter accuracy measures for maximum likelihood estimates with colored residuals. This result is important because experience from the analysis of measured data reveals that the residuals from maximum likelihood estimation are almost always colored. The calculations involved can be appended to conventional maximum likelihood estimation algorithms. Simulated data runs were used to show that the parameter accuracy measures computed with this technique accurately reflect the quality of the parameter estimates from maximum likelihood estimation without the need for analysis of the output residuals in the frequency domain or heuristically determined multiplication factors. The result is general, although the application studied here is maximum likelihood estimation of aerodynamic model parameters from flight test data.

  7. Definition and application of a five-parameter characterization of one-dimensional cellular automata rule space.

    PubMed

    Oliveira, G M; de Oliveira, P P; Omar, N

    2001-01-01

    Cellular automata (CA) are important as prototypical, spatially extended, discrete dynamical systems. Because the problem of forecasting dynamic behavior of CA is undecidable, various parameter-based approximations have been developed to address the problem. Out of the analysis of the most important parameters available to this end we proposed some guidelines that should be followed when defining a parameter of that kind. Based upon the guidelines, new parameters were proposed and a set of five parameters was selected; two of them were drawn from the literature and three are new ones, defined here. This article presents all of them and makes their qualities evident. Then, two results are described, related to the use of the parameter set in the Elementary Rule Space: a phase transition diagram, and some general heuristics for forecasting the dynamics of one-dimensional CA. Finally, as an example of the application of the selected parameters in high cardinality spaces, results are presented from experiments involving the evolution of radius-3 CA in the Density Classification Task, and radius-2 CA in the Synchronization Task.

  8. Impact of commercial housing systems and nutrient and energy intake on laying hen performance and egg quality parameters1

    PubMed Central

    Karcher, D. M.; Jones, D. R.; Abdo, Z.; Zhao, Y.; Shepherd, T. A.; Xin, H.

    2015-01-01

    The US egg industry is exploring alternative housing systems for laying hens. However, limited published research related to cage-free aviary systems and enriched colony cages exists related to production, egg quality, and hen nutrition. The laying hen's nutritional requirements and resulting productivity are well established with the conventional cage system, but diminutive research is available in regards to alternative housing systems. The restrictions exist with limited availability of alternative housing systems in research settings and the considerable expense for increased bird numbers in a replicate due to alternative housing system design. Therefore, the objective of the current study was to evaluate the impact of nutrient and energy intake on production and egg quality parameters from laying hens housed at a commercial facility. Lohmann LSL laying hens were housed in three systems: enriched colony cage, cage-free aviary, and conventional cage at a single commercial facility. Daily production records were collected along with dietary changes during 15 production periods (28-d each). Eggs were analyzed for shell strength, shell thickness, Haugh unit, vitelline membrane properties, and egg solids each period. An analysis of covariance (ANCOVA) coupled with a principal components analysis (PCA) approach was utilized to assess the impact of nutritional changes on production parameters and monitored egg quality factors. The traits of hen-day production and mortality had a response only in the PCA 2 direction. This finds that as house temperature and Met intake increases, there is an inflection point at which hen-day egg production is negatively effected. Dietary changes more directly influenced shell parameters, vitelline membrane parameters, and egg total solids as opposed to laying hen housing system. Therefore, further research needs to be conducted in controlled research settings on laying hen nutrient and energy intake in the alternative housing systems and resulting impact on egg quality measures. PMID:25630672

  9. Impact of commercial housing systems and nutrient and energy intake on laying hen performance and egg quality parameters.

    PubMed

    Karcher, D M; Jones, D R; Abdo, Z; Zhao, Y; Shepherd, T A; Xin, H

    2015-03-01

    The US egg industry is exploring alternative housing systems for laying hens. However, limited published research related to cage-free aviary systems and enriched colony cages exists related to production, egg quality, and hen nutrition. The laying hen's nutritional requirements and resulting productivity are well established with the conventional cage system, but diminutive research is available in regards to alternative housing systems. The restrictions exist with limited availability of alternative housing systems in research settings and the considerable expense for increased bird numbers in a replicate due to alternative housing system design. Therefore, the objective of the current study was to evaluate the impact of nutrient and energy intake on production and egg quality parameters from laying hens housed at a commercial facility. Lohmann LSL laying hens were housed in three systems: enriched colony cage, cage-free aviary, and conventional cage at a single commercial facility. Daily production records were collected along with dietary changes during 15 production periods (28-d each). Eggs were analyzed for shell strength, shell thickness, Haugh unit, vitelline membrane properties, and egg solids each period. An analysis of covariance (ANCOVA) coupled with a principal components analysis (PCA) approach was utilized to assess the impact of nutritional changes on production parameters and monitored egg quality factors. The traits of hen-day production and mortality had a response only in the PCA 2 direction. This finds that as house temperature and Met intake increases, there is an inflection point at which hen-day egg production is negatively effected. Dietary changes more directly influenced shell parameters, vitelline membrane parameters, and egg total solids as opposed to laying hen housing system. Therefore, further research needs to be conducted in controlled research settings on laying hen nutrient and energy intake in the alternative housing systems and resulting impact on egg quality measures. © The Author 2015. Published by Oxford University Press on behalf of Poultry Science Association.

  10. High resolution light microscopic evaluation of boar semen quality sperm cytoplasmic droplet retention in relationship with boar fertility parameters.

    PubMed

    Lovercamp, K W; Safranski, T J; Fischer, K A; Manandhar, G; Sutovsky, M; Herring, W; Sutovsky, P

    2007-01-01

    The purpose of this study was to investigate the relationship between fertility and quantitative measures of boar semen quality, including various patterns of sperm cytoplasmic droplet (CD) retention, as determined by high power differential interference contrast (DIC) microscopy. A total of 116 ejaculates were collected from a nucleus herd of 18 Large White boars over an eight month period. Semen quality parameters were analyzed for each ejaculate by calculating the percentage of normal spermatozoa, spermatozoa possessing a CD in the proximal, distal, or distal midpiece reflex position, total spermatozoa with an attached cytoplasmic droplet, spermatozoa with non-CD related aberrations and total spermatozoa with abnormalities. Of the 116 ejaculates received, 71 ejaculates from 13 boars had corresponding fertility data from single-sire inseminations of multiparous sows. The fertility data included farrowing rate (FR) and total number born (TNB). The monthly FR encompassed one month before and one month after the date of semen collection. Detection of differences for fertility and semen quality parameters was performed by separating the boars into either an above-average or below-average group based on the mean FR (74.01 +/- 1.43%) or TNB (12.34 +/- 0.17) for the study. For FR, the boars in the below-average group had a significantly lower percentage of normal spermatozoa and significantly higher percentage of spermatozoa possessing distal CDs, total attached CDs and total abnormalities compared to the boars in the above-average group. Conversely, for TNB there were no significant differences between the above- and below-average groups for the semen quality parameters. These data suggest that the attached CD may negatively affect FR, but not TNB. The detection of relationships between the boar fertility parameters and the retention of the sperm CD after ejaculation, document the advantage of high power DIC microscopy in conventional semen evaluation.

  11. Influence of Different Container Closure Systems and Capping Process Parameters on Product Quality and Container Closure Integrity (CCI) in GMP Drug Product Manufacturing.

    PubMed

    Mathaes, Roman; Mahler, Hanns-Christian; Roggo, Yves; Huwyler, Joerg; Eder, Juergen; Fritsch, Kamila; Posset, Tobias; Mohl, Silke; Streubel, Alexander

    2016-01-01

    Capping equipment used in good manufacturing practice manufacturing features different designs and a variety of adjustable process parameters. The overall capping result is a complex interplay of the different capping process parameters and is insufficiently described in literature. It remains poorly studied how the different capping equipment designs and capping equipment process parameters (e.g., pre-compression force, capping plate height, turntable rotating speed) contribute to the final residual seal force of a sealed container closure system and its relation to container closure integrity and other drug product quality parameters. Stopper compression measured by computer tomography correlated to residual seal force measurements.In our studies, we used different container closure system configurations from different good manufacturing practice drug product fill & finish facilities to investigate the influence of differences in primary packaging, that is, vial size and rubber stopper design on the capping process and the capped drug product. In addition, we compared two large-scale good manufacturing practice manufacturing capping equipment and different capping equipment settings and their impact on product quality and integrity, as determined by residual seal force.The capping plate to plunger distance had a major influence on the obtained residual seal force values of a sealed vial, whereas the capping pre-compression force and the turntable rotation speed showed only a minor influence on the residual seal force of a sealed vial. Capping process parameters could not easily be transferred from capping equipment of different manufacturers. However, the residual seal force tester did provide a valuable tool to compare capping performance of different capping equipment. No vial showed any leakage greater than 10(-8)mbar L/s as measured by a helium mass spectrometry system, suggesting that container closure integrity was warranted in the residual seal force range tested for the tested container closure systems. Capping equipment used in good manufacturing practice manufacturing features different designs and a variety of adjustable process parameters. The overall capping result is a complex interplay of the different capping process parameters and is insufficiently described in the literature. It remains poorly studied how the different capping equipment designs and capping equipment process parameters contribute to the final capping result.In this study, we used different container closure system configurations from different good manufacturing process drug product fill & finish facilities to investigate the influence of the vial size and the rubber stopper design on the capping process. In addition, we compared two examples of large-scale good manufacturing process capping equipment and different capping equipment settings and their impact on product quality and integrity, as determined by residual seal force. © PDA, Inc. 2016.

  12. Rapid performance modeling and parameter regression of geodynamic models

    NASA Astrophysics Data System (ADS)

    Brown, J.; Duplyakin, D.

    2016-12-01

    Geodynamic models run in a parallel environment have many parameters with complicated effects on performance and scientifically-relevant functionals. Manually choosing an efficient machine configuration and mapping out the parameter space requires a great deal of expert knowledge and time-consuming experiments. We propose an active learning technique based on Gaussion Process Regression to automatically select experiments to map out the performance landscape with respect to scientific and machine parameters. The resulting performance model is then used to select optimal experiments for improving the accuracy of a reduced order model per unit of computational cost. We present the framework and evaluate its quality and capability using popular lithospheric dynamics models.

  13. Subjective ranking of concert halls substantiated through orthogonal objective parameters.

    PubMed

    Cerdá, Salvador; Giménez, Alicia; Cibrián, Rosa; Girón, Sara; Zamarreño, Teófilo

    2015-02-01

    This paper studies the global subjective assessment, obtained from mean values of the results of surveys addressed to members of the audience of live concerts in Spanish auditoriums, through the mean values of the three orthogonal objective parameters (Tmid, IACCE3, and LEV), expressed in just noticeable differences (JNDs), regarding the best-valued hall. Results show that a linear combination of the relative variations of orthogonal parameters can largely explain the overall perceived quality of the sample. However, the mean values of certain orthogonal parameters are not representative, which shows that an alternative approach to the problem is necessary. Various possibilities are proposed.

  14. Simulation of optimum parameters for GaN MSM UV photodetector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alhelfi, Mohanad A., E-mail: mhad12344@gmail.com; Ahmed, Naser M., E-mail: nas-tiji@yahoo.com; Hashim, M. R., E-mail: roslan@usm.my

    2016-07-06

    In this study the optimum parameters of GaN M-S-M photodetector are discussed. The evaluation of the photodetector depends on many parameters, the most of the important parameters the quality of the GaN film and others depend on the geometry of the interdigited electrode. In this simulation work using MATLAB software with consideration of the reflection and absorption on the metal contacts, a detailed study involving various electrode spacings (S) and widths (W) reveals conclusive results in device design. The optimum interelectrode design for interdigitated MSM-PD has been specified and evaluated by effect on quantum efficiency and responsivity.

  15. Impact of the time scale of model sensitivity response on coupled model parameter estimation

    NASA Astrophysics Data System (ADS)

    Liu, Chang; Zhang, Shaoqing; Li, Shan; Liu, Zhengyu

    2017-11-01

    That a model has sensitivity responses to parameter uncertainties is a key concept in implementing model parameter estimation using filtering theory and methodology. Depending on the nature of associated physics and characteristic variability of the fluid in a coupled system, the response time scales of a model to parameters can be different, from hourly to decadal. Unlike state estimation, where the update frequency is usually linked with observational frequency, the update frequency for parameter estimation must be associated with the time scale of the model sensitivity response to the parameter being estimated. Here, with a simple coupled model, the impact of model sensitivity response time scales on coupled model parameter estimation is studied. The model includes characteristic synoptic to decadal scales by coupling a long-term varying deep ocean with a slow-varying upper ocean forced by a chaotic atmosphere. Results show that, using the update frequency determined by the model sensitivity response time scale, both the reliability and quality of parameter estimation can be improved significantly, and thus the estimated parameters make the model more consistent with the observation. These simple model results provide a guideline for when real observations are used to optimize the parameters in a coupled general circulation model for improving climate analysis and prediction initialization.

  16. Water Quality Characteristics of Sembrong Dam Reservoir, Johor, Malaysia

    NASA Astrophysics Data System (ADS)

    Mohd-Asharuddin, S.; Zayadi, N.; Rasit, W.; Othman, N.

    2016-07-01

    A study of water quality and heavy metal content in Sembrong Dam water was conducted from April - August 2015. A total of 12 water quality parameters and 6 heavy metals were measured and classified based on the Interim National Water Quality Standard of Malaysia (INWQS). The measured and analyzed parameter variables were divided into three main categories which include physical, chemical and heavy metal contents. Physical and chemical parameter variables were temperature, dissolved oxygen (DO), biochemical oxygen demand (BOD), chemical oxygen demand (COD), total suspended solid (TSS), turbidity, pH, nitrate, phosphate, ammonium, conductivity and salinity. The heavy metals measured were copper (Cu), lead (Pb), aluminium (Al), chromium (Cr), ferum (Fe) and zinc (Zn). According to INWQS, the water salinity, conductivity, BOD, TSS and nitrate level fall under Class I, while the Ph, DO and turbidity lie under Class IIA. Furthermore, values of COD and ammonium were classified under Class III. The result also indicates that the Sembrong Dam water are not polluted with heavy metals since all heavy metal readings recorded were falls far below Class I.

  17. Nutrient composition and technological quality of meat from alpacas reared in Peru.

    PubMed

    Salvá, Bettit K; Zumalacárregui, José M; Figueira, Ana C; Osorio, María T; Mateo, Javier

    2009-08-01

    The aim of this study was to increase the knowledge on alpaca meat quality characteristics. Twenty Huacaya breed alpacas, reared under a traditional unspecialized production system at the Andean region of Peru, were slaughtered at ages between 18 and 24months. Analyses were carried out on Longissimus thoracis and lumborum muscle (LTLM), unless otherwise specified. These included composition parameters: moisture, fat, protein, ash, minerals, amino acids, fatty acid profile (of both LTLM and perirenal fat), retinol and tocopherol concentrations and myoglobin and collagen contents. Other meat quality parameters were evaluated: pH, colour, water holding capacity and Warner-Bratzler shear-force. Alpaca LTLM was characterized by a low intramuscular fat content and mineral and amino acid compositions, polyunsaturated to saturated fatty acids ratio and conjugated linoleic acid content comparable to those found for beef and sheep meat. However, specifically, alpaca meat showed a relatively high n-6 to n-3 (3.7) ratio and low vitamin E concentration. Values of alpaca meat technological quality parameters were in the ranges reported for more conventional red meats, the exception being a lower b(∗) value.

  18. An integrated toolbox for processing and analysis of remote sensing data of inland and coastal waters - atmospheric correction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haan, J.F. de; Kokke, J.M.M.; Hoogenboom, H.J.

    1997-06-01

    Deriving thematic maps of water quality parameters from a remote sensing image requires a number of processing steps, such as calibration, atmospheric correction, air-water interface correction, and application of water quality algorithms. A prototype version of an integrated software environment has recently been developed that enables the user to perform and control these processing steps. Major parts of this environment are: (i) access to the MODTRAN 3 radiative transfer code, (ii) a database of water quality algorithms, and (iii) a spectral library of Dutch coastal and inland waters, containing subsurface irradiance reflectance spectra and associated water quality parameters. The atmosphericmore » correction part of this environment is discussed here. It is shown that this part can be used to accurately retrieve spectral signatures of inland water for wavelengths between 450 and 750 nm, provided in situ measurements are used to determine atmospheric model parameters. Assessment of the usefulness of the completely integrated software system in an operational environment requires a revised version that is presently being developed.« less

  19. Analyzing the Effect of Spinning Process Variables on Draw Frame Blended Cotton Mélange Yarn Quality

    NASA Astrophysics Data System (ADS)

    Ray, Suchibrata; Ghosh, Anindya; Banerjee, Debamalya

    2018-06-01

    An investigation has been made to study the effect of important spinning process variables namely shade depth, ring frame spindle speed and yarn twist multiplier (TM) on various yarn quality parameters like unevenness, strength, imperfection, elongation at break and hairiness index of draw frame blended cotton mélange yarn. Three factors Box and Behnken design of experiment has been used to conduct the study. The quadratic regression model is used to device the statistical inferences about sensitivity of the yarn quality parameters to the different process variables. The response surfaces are constructed for depicting the geometric representation of yarn quality parameters plotted as a function of process variables. Analysis of the results show that yarn strength of draw frame blended cotton mélange yarn is significantly affected by shade depth and TM. Yarn unevenness is affected by shade depth and ring frame spindle speed. Yarn imperfection level is mainly influenced by the shade depth and spindle speed. The shade depth and yarn TM have shown significant impact on yarn hairiness index.

  20. Analyzing the Effect of Spinning Process Variables on Draw Frame Blended Cotton Mélange Yarn Quality

    NASA Astrophysics Data System (ADS)

    Ray, Suchibrata; Ghosh, Anindya; Banerjee, Debamalya

    2017-12-01

    An investigation has been made to study the effect of important spinning process variables namely shade depth, ring frame spindle speed and yarn twist multiplier (TM) on various yarn quality parameters like unevenness, strength, imperfection, elongation at break and hairiness index of draw frame blended cotton mélange yarn. Three factors Box and Behnken design of experiment has been used to conduct the study. The quadratic regression model is used to device the statistical inferences about sensitivity of the yarn quality parameters to the different process variables. The response surfaces are constructed for depicting the geometric representation of yarn quality parameters plotted as a function of process variables. Analysis of the results show that yarn strength of draw frame blended cotton mélange yarn is significantly affected by shade depth and TM. Yarn unevenness is affected by shade depth and ring frame spindle speed. Yarn imperfection level is mainly influenced by the shade depth and spindle speed. The shade depth and yarn TM have shown significant impact on yarn hairiness index.

  1. Indoor air quality in Portuguese archives: a snapshot on exposure levels.

    PubMed

    Pinheiro, A C; Viegas, C; Viegas, S; Veríssimo, C; Brandão, J; Macedo, M F

    2012-01-01

    Indoor air quality recently entered legislation in Portugal. Several parameters must be evaluated and kept within limits in order to obtain a certification for air quality and energy consumption. Certification parameters were analyzed in two Portuguese archives in order to assess indoor air quality both for people attending or working on these premises and for maintenance of a written heritage that must be retained for future generations. Carbon monoxide (CO) and carbon dioxide (CO₂), formaldehyde, and fungal counts were kept within stipulated limits. Relative humidity (RH), volatile organic compounds (VOC), particulate matter (PM₁₀), and ozone (O₃) showed values above legislated levels and justified the implementation of corrective measures. In terms of conservation, studies on the limit values are still needed, but according to the available international guidelines, some of the analyzed parameters such as PM₁₀, O₃, and RH were also above desirable values. Corrective measures were proposed to these institutions. Although this study was only of a short duration, it proved valuable in assessing potential eventual problems and constitutes the first Portuguese indoor air quality assessment taking into consideration both aspects of an archive such as human health and heritage safekeeping.

  2. Perceived indoor air quality and its relationship to air pollutants in French dwellings.

    PubMed

    Langer, S; Ramalho, O; Le Ponner, E; Derbez, M; Kirchner, S; Mandin, C

    2017-11-01

    Perception of indoor air quality (PIAQ) was evaluated in a nationwide survey of 567 French dwellings, and this survey was combined with measurements of gaseous and particulate matter (PM 10 and PM 2.5 ) indoor air pollutants and indoor climate parameters. The perception was assessed on a nine-grade scale by both the occupants of the dwellings and the inspectors who performed the measurements. The occupants perceived the air quality in their homes as more pleasant than the inspectors. The inspectors perceived the air quality as more unpleasant in dwellings in which the residents smoked indoors. Significant associations between PIAQ and indoor air pollutant concentrations were observed for both the inspectors and, to a lesser extent, the occupants. Introducing confounding parameters, such as building and personal characteristics, into a multivariate model suppressed most of the observed bivariate correlations and identified the tenure status of the occupants and their occupation as the parameters that most influenced their PIAQ. For the inspectors, perceived air quality was affected by the presence of smokers, the season, the type of ventilation, retrofitting, and the concentrations of acetaldehyde and acrolein. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Effect of long term chilled (up to 5weeks) then frozen (up to 12months) storage at two different sub-zero holding temperatures on beef: 1. Meat quality and microbial loads.

    PubMed

    Holman, Benjamin W B; Coombs, Cassius E O; Morris, Stephen; Kerr, Matthew J; Hopkins, David L

    2017-11-01

    Beef loins (LL) stored under different chilled-then-frozen storage combinations (up to 5 and 52weeks, respectively) and two frozen holding temperatures were evaluated for microbial load and meat quality parameters. We found holding temperature effects to be negligible, which suggest -12°C could deliver comparable quality LL to -18°C across these same storage periods. Meat quality parameters varied significantly, but when compared to existing consumer thresholds these may not be perceptible, colour being the exception which proved unacceptable, earlier into retail display when either chilled and subsequent frozen storage periods were increased. There was insufficient detection of key spoilage microbes to allow for statistical analysis, potentially due to the hygienic and commercially representative LL source, although variation in water activity, glycogen content, pH and other moisture parameters conducive to microbial proliferation were influenced by chilled-then-frozen storage. These outcomes could be applied to defining storage thresholds that assure beef quality within export networks, leveraging market access, and improving product management. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  4. Effects of land cover, topography, and built structure on seasonal water quality at multiple spatial scales.

    PubMed

    Pratt, Bethany; Chang, Heejun

    2012-03-30

    The relationship among land cover, topography, built structure and stream water quality in the Portland Metro region of Oregon and Clark County, Washington areas, USA, is analyzed using ordinary least squares (OLS) and geographically weighted (GWR) multiple regression models. Two scales of analysis, a sectional watershed and a buffer, offered a local and a global investigation of the sources of stream pollutants. Model accuracy, measured by R(2) values, fluctuated according to the scale, season, and regression method used. While most wet season water quality parameters are associated with urban land covers, most dry season water quality parameters are related topographic features such as elevation and slope. GWR models, which take into consideration local relations of spatial autocorrelation, had stronger results than OLS regression models. In the multiple regression models, sectioned watershed results were consistently better than the sectioned buffer results, except for dry season pH and stream temperature parameters. This suggests that while riparian land cover does have an effect on water quality, a wider contributing area needs to be included in order to account for distant sources of pollutants. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. CASA-Mot in mammals: an update.

    PubMed

    Yániz, J L; Silvestre, M A; Santolaria, P; Soler, C

    2018-03-08

    Sperm motility is one of the most widely used parameters of sperm quality. Computer-aided sperm motility analysis (CASA-Mot) systems were developed to reduce the subjectivity of sperm motility assessment, and have had broad scientific and practical acceptance. In this review, the sources of variation and current applications of this technology and its relationships with other sperm quality tests are described in detail. Despite remarkable advances in the technique, there is still great need for standardisation in many species, and the numerous factors that affect the results make it difficult to provide universally accepted criteria for classifying semen samples based on sperm motility characteristics. The main fields for CASA-Mot include the study of male fertility and pathologies, evaluation of the effects of physical and chemical agents, improvement of epidemiological survey studies, more precise calculation of seminal doses for farm animals, realisation of basic studies about sperm function, improvement of sperm technologies such as cryopreservation and quality control analysis. Numerous relationships have been established between CASA-Mot and other sperm quality tests, although most of these parameters are complementary. Future CASA-Mot systems will probably be able to integrate several sperm quality parameters with motility.

  6. Use of EO-1 Advanced Land Imager (ALI) multispectral image data and real-time field sampling for water quality mapping in the Hirfanlı Dam Lake, Turkey.

    PubMed

    Kavurmacı, Murat; Ekercin, Semih; Altaş, Levent; Kurmaç, Yakup

    2013-08-01

    This paper focuses on the evaluation of water quality variations in Hirfanlı Water Reservoir, which is one of the most important water resources in Turkey, through EO-1 (Earth Observing-1) Advanced Land Imager (ALI) multispectral data and real-time field sampling. The study was materialized in 20 different sampling points during the overpass of the EO-1 ALI sensor over the study area. A multi-linear regression technique was used to explore the relationships between radiometrically corrected EO-1 ALI image data and water quality parameters: chlorophyll a, turbidity, and suspended solids. The retrieved and verified results show that the measured and estimated values of water quality parameters are in good agreement (R (2) >0.93). The resulting thematic maps derived from EO-1 multispectral data for chlorophyll a, turbidity, and suspended solids show the spatial distribution of the water quality parameters. The results indicate that the reservoir has average nutrient values. Furthermore, chlorophyll a, turbidity, and suspended solids values increased at the upstream reservoir and shallow coast of the Hirfanlı Water Reservoir.

  7. Development of on package indicator sensor for real-time monitoring of meat quality

    PubMed Central

    Shukla, Vivek; Kandeepan, G.; Vishnuraj, M. R.

    2015-01-01

    Aim: The aim was to develop an indicator sensor for real-time monitoring of meat quality and to compare the response of indicator sensor with meat quality parameters at ambient temperature. Materials and Methods: Indicator sensor was prepared using bromophenol blue (1% w/v) as indicator solution and filter paper as indicator carrier. Indicator sensor was fabricated by coating indicator solution onto carrier by centrifugation. To observe the response of indicator sensor buffalo meat was packed in polystyrene foam trays covered with PVC film and indicator sensor was attached to the inner side of packaging film. The pattern of color change in indicator sensor was monitored and compared with meat quality parameters viz. total volatile basic nitrogen, D-glucose, standard plate count and tyrosine value to correlate ability of indicator sensor for its suitability to predict the meat quality and storage life. Results: The indicator sensor changed its color from yellow to blue starting from margins during the storage period of 24 h at ambient temperature and this correlated well with changes in meat quality parameters. Conclusions: The indicator sensor can be used for real-time monitoring of meat quality as the color of indicator sensor changed from yellow to blue starting from margins when meat deteriorates with advancement of the storage period. Thus by observing the color of indicator sensor quality of meat and shelf life can be predicted. PMID:27047103

  8. Diagnostic Abilities of Variable and Enhanced Corneal Compensation Algorithms of GDx in Different Severities of Glaucoma.

    PubMed

    Yadav, Ravi K; Begum, Viquar U; Addepalli, Uday K; Senthil, Sirisha; Garudadri, Chandra S; Rao, Harsha L

    2016-02-01

    To compare the abilities of retinal nerve fiber layer (RNFL) parameters of variable corneal compensation (VCC) and enhanced corneal compensation (ECC) algorithms of scanning laser polarimetry (GDx) in detecting various severities of glaucoma. Two hundred and eighty-five eyes of 194 subjects from the Longitudinal Glaucoma Evaluation Study who underwent GDx VCC and ECC imaging were evaluated. Abilities of RNFL parameters of GDx VCC and ECC to diagnose glaucoma were compared using area under receiver operating characteristic curves (AUC), sensitivities at fixed specificities, and likelihood ratios. After excluding 5 eyes that failed to satisfy manufacturer-recommended quality parameters with ECC and 68 with VCC, 56 eyes of 41 normal subjects and 161 eyes of 121 glaucoma patients [36 eyes with preperimetric glaucoma, 52 eyes with early (MD>-6 dB), 34 with moderate (MD between -6 and -12 dB), and 39 with severe glaucoma (MD<-12 dB)] were included for the analysis. Inferior RNFL, average RNFL, and nerve fiber indicator parameters showed the best AUCs and sensitivities both with GDx VCC and ECC in diagnosing all severities of glaucoma. AUCs and sensitivities of all RNFL parameters were comparable between the VCC and ECC algorithms (P>0.20 for all comparisons). Likelihood ratios associated with the diagnostic categorization of RNFL parameters were comparable between the VCC and ECC algorithms. In scans satisfying the manufacturer-recommended quality parameters, which were significantly greater with ECC than VCC algorithm, diagnostic abilities of GDx ECC and VCC in glaucoma were similar.

  9. Lumped Parameter experiments for Single Mode Fiber Laser Cutting of Thin Stainless Steel Plate

    NASA Astrophysics Data System (ADS)

    Lai, Shengying; Jia, Ye; Han, Bing; Wang, Jun; Liu, Zongkai; Ni, Xiaowu; Shen, Zhonghua; Lu, Jian

    2017-06-01

    The present work reports the parameters on laser cutting stainless steel including workpiece thickness, cutting speed, defocus length and assisting gas pressure. The cutting kerf width, dross attachment and cut edge squareness deviation are examined to provide information on cutting quality. The results show that with the increasing thickness, the cutting speed decrease rate is about 27%. The optimal ranges of cutting speed, defocus length and gas pressure are obtained with maximum quality. The first section in your paper

  10. Use of PFU protozoan community structural and functional characteristics in assessment of water quality in a large, highly polluted freshwater lake in China.

    PubMed

    Xu, Muqi; Cao, Hong; Xie, Ping; Deng, Daogui; Feng, Weisong; Xu, Jian

    2005-07-01

    Structural and functional parameters of protozoan communities colonizing on PFU (polyurethane foam unit) artificial substrate were assessed as indicators of water quality in the Chaohu Lake, a large, shallow and highly polluted freshwater lake in China. Protozoan communities were sampled 1, 3, 6, 9 and 14 days after exposure of PFU artificial substrate in the lake during October 2003. Four study stations with the different water quality gradient changes along the lake were distinguishable in terms of differences in the community's structural (species richness, individual abundance, etc.) and functional parameters (protozoan colonization rates on PFU). The concentrations of TP, TN, COD and BOD as the main chemical indicators of pollution at the four sampling sites were also obtained each year during 2002-2003 for comparison with biological parameters. The results showed that the species richness and PFU colonization rate decreased as pollution intensity increased and that the Margalef diversity index values calculated at four sampling sites also related to water quality. The three functional parameters based on the PFU colonization process, that is, S(eq), G and T90%, were strongly related to the pollution status of the water. The number of protozoan species colonizing on PFU after exposure of 1 to 3 days was found to give a clear comparative indication of the water quality at the four sampling stations. The research provides further evidence that the protozoan community may be utilized effectively in the assessment of water quality and that the PFU method furnishes rapid, cost-effective and reliable information that may be useful for measuring responses to pollution stress in aquatic ecosystems.

  11. Temporal variability in water quality parameters--a case study of drinking water reservoir in Florida, USA.

    PubMed

    Toor, Gurpal S; Han, Lu; Stanley, Craig D

    2013-05-01

    Our objective was to evaluate changes in water quality parameters during 1983-2007 in a subtropical drinking water reservoir (area: 7 km(2)) located in Lake Manatee Watershed (area: 338 km(2)) in Florida, USA. Most water quality parameters (color, turbidity, Secchi depth, pH, EC, dissolved oxygen, total alkalinity, cations, anions, and lead) were below the Florida potable water standards. Concentrations of copper exceeded the potable water standard of <30 μg l(-1) in about half of the samples. About 75 % of total N in lake was organic N (0.93 mg l(-1)) with the remainder (25 %) as inorganic N (NH3-N: 0.19, NO3-N: 0.17 mg l(-1)), while 86 % of total P was orthophosphate. Mean total N/P was <6:1 indicating N limitation in the lake. Mean monthly concentration of chlorophyll-a was much lower than the EPA water quality threshold of 20 μg l(-1). Concentrations of total N showed significant increase from 1983 to 1994 and a decrease from 1997 to 2007. Total P showed significant increase during 1983-2007. Mean concentrations of total N (n = 215; 1.24 mg l(-1)) were lower, and total P (n = 286; 0.26 mg l(-1)) was much higher than the EPA numeric criteria of 1.27 mg total N l(-1) and 0.05 mg total P l(-1) for Florida's colored lakes, respectively. Seasonal trends were observed for many water quality parameters where concentrations were typically elevated during wet months (June-September). Results suggest that reducing transport of organic N may be one potential option to protect water quality in this drinking water reservoir.

  12. Hydro-chemical Survey and Quantifying Spatial Variations of Groundwater Quality in Dwarka, Sub-city of Delhi, India

    NASA Astrophysics Data System (ADS)

    Rawat, Kishan Singh; Tripathi, Vinod Kumar

    2015-06-01

    Hydrological and geological aspect of the region play vital role for water resources utilization and development. Protection and management of groundwater resources are possible with the study of spatio-temporal water quality parameters. The study was undertaken to assess the deterioration in groundwater quality, through systematic sampling during post monsoon seasons of the year 2008 by collecting water samples from thirty bore wells located in Dwarka, sub-city of Delhi, India. The average concentrations of groundwater quality parameters namely Calcium (Ca2+), Magnesium (Mg2+), Nitrate (NO3 -), Chloride (Cl-), sulphate (SO4 2-), total hardness (TH), total dissolved solids (TDS), and electrical conductivity were 300, 178, 26.5, 301, 103, 483, 1042 mg/l and 1909 μS/cm respectively. Estimated physico-chemical parameters revealed that 7 % of the groundwater samples shown nitrate concentrations higher than safe limit prescribed by World Health Organization (WHO). Groundwater quality the in study region was poor due to come out result that NO3 - concentration exceeding the threshold value of 50 mg/l, and main cause is disposal of sewage and animal wastes to Najafgarh drain. Dominant cations are Mg2+, Ca2+ and anions are SO4 2- and Cl-. The abundance of the major ions in groundwater is in the order: Ca2+ > Mg2+ and Cl- > SO4 2- > NO3. TH have strong correlation with Ca2+ (r = 0.81), Mg2+ (r = 0.82), Cl- (r = 0.86) but poor correlation with TDS (r = 0.52). Knowledge of correlation values between water quality parameters is helpful to take decision of appropriate management strategy for controlling groundwater pollution.

  13. Recommended Parameter Values for GENII Modeling of Radionuclides in Routine Air and Water Releases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Snyder, Sandra F.; Arimescu, Carmen; Napier, Bruce A.

    The GENII v2 code is used to estimate dose to individuals or populations from the release of radioactive materials into air or water. Numerous parameter values are required for input into this code. User-defined parameters cover the spectrum from chemical data, meteorological data, agricultural data, and behavioral data. This document is a summary of parameter values that reflect conditions in the United States. Reasonable regional and age-dependent data is summarized. Data availability and quality varies. The set of parameters described address scenarios for chronic air emissions or chronic releases to public waterways. Considerations for the special tritium and carbon-14 modelsmore » are briefly addressed. GENIIv2.10.0 is the current software version that this document supports.« less

  14. Development of innovative computer software to facilitate the setup and computation of water quality index.

    PubMed

    Nabizadeh, Ramin; Valadi Amin, Maryam; Alimohammadi, Mahmood; Naddafi, Kazem; Mahvi, Amir Hossein; Yousefzadeh, Samira

    2013-04-26

    Developing a water quality index which is used to convert the water quality dataset into a single number is the most important task of most water quality monitoring programmes. As the water quality index setup is based on different local obstacles, it is not feasible to introduce a definite water quality index to reveal the water quality level. In this study, an innovative software application, the Iranian Water Quality Index Software (IWQIS), is presented in order to facilitate calculation of a water quality index based on dynamic weight factors, which will help users to compute the water quality index in cases where some parameters are missing from the datasets. A dataset containing 735 water samples of drinking water quality in different parts of the country was used to show the performance of this software using different criteria parameters. The software proved to be an efficient tool to facilitate the setup of water quality indices based on flexible use of variables and water quality databases.

  15. HIGH-SHEAR GRANULATION PROCESS: INFLUENCE OF PROCESSING PARAMETERS ON CRITICAL QUALITY ATTRIBUTES OF ACETAMINOPHEN GRANULES AND TABLETS USING DESIGN OF EXPERIMENT APPROACH.

    PubMed

    Fayed, Mohamed H; Abdel-Rahman, Sayed I; Alanazi, Fars K; Ahmed, Mahrous O; Tawfeek, Hesham M; Al-Shedfat, Ramadan I

    2017-01-01

    Application of quality by design (QbD) in high shear granulation process is critical and need to recognize the correlation between the granulation process parameters and the properties of intermediate (granules) and corresponding final product (tablets). The present work examined the influence of water amount (X,) and wet massing time (X2) as independent process variables on the critical quality attributes of granules and corresponding tablets using design of experiment (DoE) technique. A two factor, three level (32) full factorial design was performed; each of these variables was investigated at three levels to characterize their strength and interaction. The dried granules have been analyzed for their size distribution, density and flow pattern. Additionally, the produced tablets have been investigated for weight uniformity, crushing strength, friability and percent capping, disintegration time and drug dissolution. Statistically significant impact (p < 0.05) of water amount was identified for granule growth, percent fines and distribution width and flow behavior. Granule density and compressibility were found to be significantly influenced (p < 0.05) by the two operating conditions. Also, water amount has significant effect (p < 0.05) on tablet weight unifornity, friability and percent capping. Moreover, tablet disintegration time and drug dissolution appears to be significantly influenced (p < 0.05) by the two process variables. On the other hand, the relationship of process parameters with critical quality attributes of granule and final product tablet was identified and correlated. Ultimately, a judicious selection of process parameters in high shear granulation process will allow providing product of desirable quality.

  16. Integrated analysis of numerical weather prediction and computational fluid dynamics for estimating cross-ventilation effects on inhaled air quality inside a factory

    NASA Astrophysics Data System (ADS)

    Murga, Alicia; Sano, Yusuke; Kawamoto, Yoichi; Ito, Kazuhide

    2017-10-01

    Mechanical and passive ventilation strategies directly impact indoor air quality. Passive ventilation has recently become widespread owing to its ability to reduce energy demand in buildings, such as the case of natural or cross ventilation. To understand the effect of natural ventilation on indoor environmental quality, outdoor-indoor flow paths need to be analyzed as functions of urban atmospheric conditions, topology of the built environment, and indoor conditions. Wind-driven natural ventilation (e.g., cross ventilation) can be calculated through the wind pressure coefficient distributions of outdoor wall surfaces and openings of a building, allowing the study of indoor air parameters and airborne contaminant concentrations. Variations in outside parameters will directly impact indoor air quality and residents' health. Numerical modeling can contribute to comprehend these various parameters because it allows full control of boundary conditions and sampling points. In this study, numerical weather prediction modeling was used to calculate wind profiles/distributions at the atmospheric scale, and computational fluid dynamics was used to model detailed urban and indoor flows, which were then integrated into a dynamic downscaling analysis to predict specific urban wind parameters from the atmospheric to built-environment scale. Wind velocity and contaminant concentration distributions inside a factory building were analyzed to assess the quality of the human working environment by using a computer simulated person. The impact of cross ventilation flows and its variations on local average contaminant concentration around a factory worker, and inhaled contaminant dose, were then discussed.

  17. The correlation of Acanthamoeba from the ventilation system with other environmental parameters in commercial buildings as possible indicator for indoor air quality.

    PubMed

    Ooi, Soo Shen; Mak, Joon Wah; Chen, Donald K F; Ambu, Stephen

    2017-02-07

    The free-living protozoan Acanthamoeba is an opportunistic pathogen that is ubiquitous in our environment. However, its role in affecting indoor air quality and ill-health of indoor occupants is relatively unknown. The present study investigated the presence of Acanthamoeba from the ventilation system and its correlation with other indoor air quality parameters, used in the industry code of practice and its potential as an indicator for indoor air quality. Indoor air quality assessments were carried out in nine commercial buildings with approval from the building management, and the parameters assessed were as recommended by the Department of Occupational Safety and Health. The presence of Acanthamoeba was determined through dust swabs from the ventilation system and indoor furniture. Logistic regression was performed to study the correlation between assessed parameters and occupants' complaints. A total of 107 sampling points were assessed and 40.2% of the supplying air diffuser and blowing fan and 15% of the furniture were positive for cysts. There was a significant correlation between Acanthamoeba detected from the ventilation system with ambient total fungus count (r=0.327; p=0.01) and respirable particulates (r=0.276; p=0.01). Occupants' sick building syndrome experience also correlated with the presence of Acanthamoeba in the ventilation system (r=0.361; p=0.01) and those detected on the furniture (r=0.290; p=0.01). Logistic regression showed that there was a five-fold probability of sick building syndrome among occupants when Acanthamoeba was detected in the ventilation system.

  18. The correlation of Acanthamoeba from the ventilation system with other environmental parameters in commercial buildings as possible indicator for indoor air quality

    PubMed Central

    OOI, Soo Shen; MAK, Joon Wah; CHEN, Donald K.F.; AMBU, Stephen

    2016-01-01

    The free-living protozoan Acanthamoeba is an opportunistic pathogen that is ubiquitous in our environment. However, its role in affecting indoor air quality and ill-health of indoor occupants is relatively unknown. The present study investigated the presence of Acanthamoeba from the ventilation system and its correlation with other indoor air quality parameters, used in the industry code of practice and its potential as an indicator for indoor air quality. Indoor air quality assessments were carried out in nine commercial buildings with approval from the building management, and the parameters assessed were as recommended by the Department of Occupational Safety and Health. The presence of Acanthamoeba was determined through dust swabs from the ventilation system and indoor furniture. Logistic regression was performed to study the correlation between assessed parameters and occupants’ complaints. A total of 107 sampling points were assessed and 40.2% of the supplying air diffuser and blowing fan and 15% of the furniture were positive for cysts. There was a significant correlation between Acanthamoeba detected from the ventilation system with ambient total fungus count (r=0.327; p=0.01) and respirable particulates (r=0.276; p=0.01). Occupants’ sick building syndrome experience also correlated with the presence of Acanthamoeba in the ventilation system (r=0.361; p=0.01) and those detected on the furniture (r=0.290; p=0.01). Logistic regression showed that there was a five-fold probability of sick building syndrome among occupants when Acanthamoeba was detected in the ventilation system. PMID:27476379

  19. Evaluation of Effective Parameters on Quality of Magnetic Resonance Imaging-computed Tomography Image Fusion in Head and Neck Tumors for Application in Treatment Planning.

    PubMed

    Shirvani, Atefeh; Jabbari, Keyvan; Amouheidari, Alireza

    2017-01-01

    In radiation therapy, computed tomography (CT) simulation is used for treatment planning to define the location of tumor. Magnetic resonance imaging (MRI)-CT image fusion leads to more efficient tumor contouring. This work tried to identify the practical issues for the combination of CT and MRI images in real clinical cases. The effect of various factors is evaluated on image fusion quality. In this study, the data of thirty patients with brain tumors were used for image fusion. The effect of several parameters on possibility and quality of image fusion was evaluated. These parameters include angles of the patient's head on the bed, slices thickness, slice gap, and height of the patient's head. According to the results, the first dominating factor on quality of image fusion was the difference slice gap between CT and MRI images (cor = 0.86, P < 0.005) and second factor was the angle between CT and MRI slice in the sagittal plane (cor = 0.75, P < 0.005). In 20% of patients, this angle was more than 28° and image fusion was not efficient. In 17% of patients, difference slice gap in CT and MRI was >4 cm and image fusion quality was <25%. The most important problem in image fusion is that MRI images are taken without regard to their use in treatment planning. In general, parameters related to the patient position during MRI imaging should be chosen to be consistent with CT images of the patient in terms of location and angle.

  20. Generator Dynamic Model Validation and Parameter Calibration Using Phasor Measurements at the Point of Connection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Zhenyu; Du, Pengwei; Kosterev, Dmitry

    2013-05-01

    Disturbance data recorded by phasor measurement units (PMU) offers opportunities to improve the integrity of dynamic models. However, manually tuning parameters through play-back events demands significant efforts and engineering experiences. In this paper, a calibration method using the extended Kalman filter (EKF) technique is proposed. The formulation of EKF with parameter calibration is discussed. Case studies are presented to demonstrate its validity. The proposed calibration method is cost-effective, complementary to traditional equipment testing for improving dynamic model quality.

  1. The scatter of mechanical values of carbon fiber composites and its causes. [statistical values of strength

    NASA Technical Reports Server (NTRS)

    Roth, S.

    1979-01-01

    The scatter of experimental data obtained in an investigation of the parameters of structural components was investigated. Strength parameters which are determined by the resin or the adhesion between fiber and resin were included. The statistical characteristics of the mechanical parameters of carbon fiber composites, and the possibilities which exist to reduce this scatter were emphasized. It is found that quality control tests of fiber and resin are important for such a reduction.

  2. CO 2 laser cutting of MDF . 1. Determination of process parameter settings

    NASA Astrophysics Data System (ADS)

    Lum, K. C. P.; Ng, S. L.; Black, I.

    2000-02-01

    This paper details an investigation into the laser processing of medium-density fibreboard (MDF). Part 1 reports on the determination of process parameter settings for the effective cutting of MDF by CO 2 laser, using an established experimental methodology developed to study the interrelationship between and effects of varying laser set-up parameters. Results are presented for both continuous wave (CW) and pulse mode (PM) cutting, and the associated cut quality effects have been commented on.

  3. Acoustic characteristics of voice after severe traumatic brain injury.

    PubMed

    McHenry, M

    2000-07-01

    To describe the acoustic characteristics of voice in individuals with motor speech disorders after traumatic brain injury (TBI). Prospective study of 100 individuals with TBI based on consecutive referrals for motor speech evaluations. Subjects were audio tape-recorded while producing sustained vowels and single word and sentence intelligibility tests. Laryngeal airway resistance was estimated, and voice quality was rated perceptually. None of the subjects evidenced vocal parameters within normal limits. The most frequently occurring abnormal parameter across subjects was amplitude perturbation, followed by voice turbulence index. Twenty-three percent of subjects evidenced deviation in all five parameters measured. The perceptual ratings of breathiness were significantly correlated with both the amplitude perturbation quotient and the noise-to-harmonics ratio. Vocal quality deviation is common in motor speech disorders after TBI and may impact intelligibility.

  4. The Colorado River in the Grand Canyon.

    ERIC Educational Resources Information Center

    Speece, Susan

    1991-01-01

    An assessment of the water quality of the Colorado River in the Grand Canyon was made, using the following parameters: dissolved oxygen, water temperature, hydrogen ion concentration, total dissolved solids, turbidity, and ammonium/nitrogen levels. These parameters were used to provide some clue as to the "wellness" and stability of the…

  5. Genetic parameters for milk fatty acids, milk yield and quality traits of a Holstein cattle population reared under tropical conditions

    USDA-ARS?s Scientific Manuscript database

    Information about genetic parameters is essential for selection decisions and genetic evaluation. Those estimates are population specific, but few studies are available for dairy cattle populations reared under tropical and subtropical conditions. Heritability and genetic correlations for milk yield...

  6. 40 CFR 133.101 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... arithmetic mean of pollutant parameter values for samples collected in a period of 7 consecutive days. (b) 30-day average. The arithmetic mean of pollutant parameter values of samples collected in a period of 30... percentile value for the 30-day average effluent quality achieved by a treatment works in a period of at...

  7. 40 CFR 98.35 - Procedures for estimating missing data.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 21 2014-07-01 2014-07-01 false Procedures for estimating missing data... Procedures for estimating missing data. Whenever a quality-assured value of a required parameter is... substitute data value for the missing parameter shall be used in the calculations. (a) For all units subject...

  8. 40 CFR 98.35 - Procedures for estimating missing data.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 22 2013-07-01 2013-07-01 false Procedures for estimating missing data... Procedures for estimating missing data. Whenever a quality-assured value of a required parameter is... substitute data value for the missing parameter shall be used in the calculations. (a) For all units subject...

  9. 40 CFR 98.35 - Procedures for estimating missing data.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Procedures for estimating missing data... Procedures for estimating missing data. Whenever a quality-assured value of a required parameter is... substitute data value for the missing parameter shall be used in the calculations. (a) For all units subject...

  10. 40 CFR 98.35 - Procedures for estimating missing data.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 22 2012-07-01 2012-07-01 false Procedures for estimating missing data... Procedures for estimating missing data. Whenever a quality-assured value of a required parameter is... substitute data value for the missing parameter shall be used in the calculations. (a) For all units subject...

  11. 40 CFR 98.35 - Procedures for estimating missing data.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 21 2011-07-01 2011-07-01 false Procedures for estimating missing data... Procedures for estimating missing data. Whenever a quality-assured value of a required parameter is... substitute data value for the missing parameter shall be used in the calculations. (a) For all units subject...

  12. Crystal growth of device quality GaAs in space

    NASA Technical Reports Server (NTRS)

    Gatos, H. C.; Lagowski, J.

    1979-01-01

    The optimization of space processing of GaAs is described. The detailed compositional, structural, and electronic characterization of GaAs on a macro- and microscale and the relationships between growth parameters and the properties of GaAs are among the factors discussed. The key parameters limiting device performance are assessed.

  13. Green-ampt infiltration parameters in riparian buffers

    Treesearch

    L.M. Stahr; D.E. Eisenhauer; M.J. Helmers; Mike G. Dosskey; T.G. Franti

    2004-01-01

    Riparian buffers can improve surface water quality by filtering contaminants from runoff before they enter streams. Infiltration is an important process in riparian buffers. Computer models are often used to assess the performance of riparian buffers. Accurate prediction of infiltration by these models is dependent upon accurate estimates of infiltration parameters....

  14. SU-F-T-435: Helical Tomotherapy for Craniospinal Irradiation: What We Have Learned from a Multi-Institutional Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Du, D; Kaprealian, T; Low, D

    Purpose: To report cranio-spinal irradiation (CSI) planning experience, compare dosimetric quality and delivery efficiency with Tomotherapy from different institutions, and to investigate effect of planning parameters on plan quality and treatment time. Methods: Clinical helical tomotherapy IMRT plans for thirty-nine CSI cases from three academic institutions were retrospectively evaluated. The planning parameters: field width (FW), pitch, modulation factor (MF), and achieved dosimetric endpoints were cross-compared. A fraction-dose-delivery-timing index (FDTI), defined as treatment time per fraction dose per PTV length, was utilized to evaluate plan delivery efficiency. A lower FDTI indicates higher delivery efficiency. We studied the correlation between planning quality,more » treatment time and planning parameters by grouping the plans under specific planning parameters. Additionally, we created new plans using 5cm jaw for a subset of plans that used 2.5cm jaw to exam if treatment efficiency can be improved without sacrificing plan quality. Results: There were significant dosimetric differences for organ at risks (OARs) among different institutions (A,B,C). Using the lowest average MF (1.9±0.4) and 5cm field width, C had the highest lung, heart, kidney, liver mean doses and maximum doses for lens. Using the same field width of 5cm, but higher MF (2.6±0.6), B had lower doses to the OARs in the thorax and abdomen area. Most of A’s plans were planned with 2.5cm jaw, the plans yielded better PTV coverage, higher OAR doses and slightly shorter FDTI compared to institution B. The replanned 5cm jaw plans achieved comparable PTV coverage and OARs sparing, while saving up to 44.7% treatment time. Conclusion: Plan quality and delivery efficiency could vary significantly in CSI planning on Tomotheapy due to choice of different planning parameters. CSI plans using a 5cm jaw, with proper selection of pitch and MF, can achieve comparable/ better plan quality with shorter delivery time compared to 2.5cm jaw plans.« less

  15. Testing the Visual Soil Assessment tool on Estonian farm fields

    NASA Astrophysics Data System (ADS)

    Reintam, Endla; Are, Mihkel; Selge, Are

    2017-04-01

    Soil quality estimation plays important role in decision making on farm as well on policy level. Sustaining the production ability and good health of the soil the chemical, physical and biological indicators should be taken into account. The system to use soil chemical parameters is usually quite well established in most European counties, including Estonia. However, measuring soil physical properties, such bulk density, porosity, penetration resistance, structural stability ect is time consuming, needs special tools and is highly weather dependent. In that reason these parameters are excluded from controllable quality parameters in policy in Estonia. Within the project "Interactive Soil Quality Assessment in Europe and China for Agricultural Productivity and Environmental Resilience" (iSQAPER) the visual soil assessment (VSA) tool was developed for easy detection of soil quality as well the different soil friendly agricultural management practices (AMP) were detected. The aim of current study was to test the VSA tool on Estonian farm fields under different management practices and compare the results with laboratory measurements. The main focus was set on soil physical parameters. Next to the VSA, the undisturbed soil samples were collected from the depth of 5-10 cm and 25-30 cm. The study revealed that results of a visually assessed soil physical parameters, such a soil structure, soil structural stability, soil porosity, presence of tillage pan, were confirmed by laboratory measurements in most cases. Soil water stable structure measurement on field (on 1 cm2 net in one 1 l box with 4-6 cm air dry clods for 5-10 min) underestimated very well structured soil on grassland and overestimated the structure aggregates stability of compacted soil. The slightly better soil quality was detected under no-tillage compared to ploughed soils. However, the ploughed soil got higher quality points compared with minimum tillage. The slurry application (organic manuring) had controversial impact - it increased the number of earthworms but decreased soil structural stability. Even the manuring with slurry increases organic matter amount in the soil, the compaction due to the use of heavy machinery during the application, especially on wet soil, reduces the positive effect of slurry.

  16. Inverse U-shaped Association between Sleep Duration and Semen Quality: Longitudinal Observational Study (MARHCS) in Chongqing, China

    PubMed Central

    Chen, Qing; Yang, Huan; Zhou, Niya; Sun, Lei; Bao, Huaqiong; Tan, Lu; Chen, Hongqiang; Ling, Xi; Zhang, Guowei; Huang, Linping; Li, Lianbing; Ma, Mingfu; Yang, Hao; Wang, Xiaogang; Zou, Peng; Peng, Kaige; Liu, Taixiu; Cui, Zhihong; Ao, Lin; Roenneberg, Till; Zhou, Ziyuan; Cao, Jia

    2016-01-01

    Study Objectives: To investigate the association between sleep duration and semen parameters as well as reproductive hormone levels. Methods: We designed a cohort of male college students in Chongqing, China. A total of 796 subjects were recruited in 2013 and 656 (82.4%) were followed up in 2014. Each time, semen and peripheral blood samples were collected for semen quality and reproductive hormone measurement. Sleep duration was estimated by revised Munich Chronotype Questionnaire. In 2014, sleep quality was also measured by Pittsburgh Sleep Quality Index (PSQI). Results: There was a substantial inverse U-shaped association between sleep duration and two semen parameters (semen volume and total sperm number), with 7.0–7.5 h/day of sleep showing highest parameters. Either longer or shorter sleep was associated with decreased semen parameters in a dose-response manner (P = 0.002 and 0.001, respectively). Sleeping > 9.0 h was associated with a 21.5% (95% confidence interval 9.2, 32.2) reduction in semen volume and 39.4% (23.3, 52.1) reduction in total sperm number; sleeping ≤ 6.5 h was associated with 4.6% (−10.5, 22.3) and 25.7% (−1.2, 60.1) reduction. Increase of the two parameters was found in those who changed sleep duration toward 7.0–7.5 h/day from 2013 to 2014. The U-shaped association was independent from PSQI and was replicated in another dataset of 1,346 males. No association found between sleep duration and reproductive hormone. Conclusions: Either restricted or excessive sleep may impair semen quality. Further research is needed to validate this finding. Citation: Chen Q, Yang H, Zhou N, Sun L, Bao H, Tan L, Chen H, Ling X, Zhang G, Huang L, Li L, Ma M, Yang H, Wang X, Zou P, Peng K, Liu T, Cui Z, Ao L, Roenneberg T, Zhou Z, Cao J. Inverse u-shaped association between sleep duration and semen quality: longitudinal observational study (MARHCS) in Chongqing, China. SLEEP 2016;39(1):79–86. PMID:26350472

  17. Prediction of pork quality parameters by applying fractals and data mining on MRI.

    PubMed

    Caballero, Daniel; Pérez-Palacios, Trinidad; Caro, Andrés; Amigo, José Manuel; Dahl, Anders B; ErsbØll, Bjarne K; Antequera, Teresa

    2017-09-01

    This work firstly investigates the use of MRI, fractal algorithms and data mining techniques to determine pork quality parameters non-destructively. The main objective was to evaluate the capability of fractal algorithms (Classical Fractal algorithm, CFA; Fractal Texture Algorithm, FTA and One Point Fractal Texture Algorithm, OPFTA) to analyse MRI in order to predict quality parameters of loin. In addition, the effect of the sequence acquisition of MRI (Gradient echo, GE; Spin echo, SE and Turbo 3D, T3D) and the predictive technique of data mining (Isotonic regression, IR and Multiple linear regression, MLR) were analysed. Both fractal algorithm, FTA and OPFTA are appropriate to analyse MRI of loins. The sequence acquisition, the fractal algorithm and the data mining technique seems to influence on the prediction results. For most physico-chemical parameters, prediction equations with moderate to excellent correlation coefficients were achieved by using the following combinations of acquisition sequences of MRI, fractal algorithms and data mining techniques: SE-FTA-MLR, SE-OPFTA-IR, GE-OPFTA-MLR, SE-OPFTA-MLR, with the last one offering the best prediction results. Thus, SE-OPFTA-MLR could be proposed as an alternative technique to determine physico-chemical traits of fresh and dry-cured loins in a non-destructive way with high accuracy. Copyright © 2017. Published by Elsevier Ltd.

  18. Process modeling and parameter optimization using radial basis function neural network and genetic algorithm for laser welding of dissimilar materials

    NASA Astrophysics Data System (ADS)

    Ai, Yuewei; Shao, Xinyu; Jiang, Ping; Li, Peigen; Liu, Yang; Yue, Chen

    2015-11-01

    The welded joints of dissimilar materials have been widely used in automotive, ship and space industries. The joint quality is often evaluated by weld seam geometry, microstructures and mechanical properties. To obtain the desired weld seam geometry and improve the quality of welded joints, this paper proposes a process modeling and parameter optimization method to obtain the weld seam with minimum width and desired depth of penetration for laser butt welding of dissimilar materials. During the process, Taguchi experiments are conducted on the laser welding of the low carbon steel (Q235) and stainless steel (SUS301L-HT). The experimental results are used to develop the radial basis function neural network model, and the process parameters are optimized by genetic algorithm. The proposed method is validated by a confirmation experiment. Simultaneously, the microstructures and mechanical properties of the weld seam generated from optimal process parameters are further studied by optical microscopy and tensile strength test. Compared with the unoptimized weld seam, the welding defects are eliminated in the optimized weld seam and the mechanical properties are improved. The results show that the proposed method is effective and reliable for improving the quality of welded joints in practical production.

  19. Modeling and Analysis of Process Parameters for Evaluating Shrinkage Problems During Plastic Injection Molding of a DVD-ROM Cover

    NASA Astrophysics Data System (ADS)

    Öktem, H.

    2012-01-01

    Plastic injection molding plays a key role in the production of high-quality plastic parts. Shrinkage is one of the most significant problems of a plastic part in terms of quality in the plastic injection molding. This article focuses on the study of the modeling and analysis of the effects of process parameters on the shrinkage by evaluating the quality of the plastic part of a DVD-ROM cover made with Acrylonitrile Butadiene Styrene (ABS) polymer material. An effective regression model was developed to determine the mathematical relationship between the process parameters (mold temperature, melt temperature, injection pressure, injection time, and cooling time) and the volumetric shrinkage by utilizing the analysis data. Finite element (FE) analyses designed by Taguchi (L27) orthogonal arrays were run in the Moldflow simulation program. Analysis of variance (ANOVA) was then performed to check the adequacy of the regression model and to determine the effect of the process parameters on the shrinkage. Experiments were conducted to control the accuracy of the regression model with the FE analyses obtained from Moldflow. The results show that the regression model agrees very well with the FE analyses and the experiments. From this, it can be concluded that this study succeeded in modeling the shrinkage problem in our application.

  20. Influence of experimental parameters on the microencapsulation of a photopolymerizable phase.

    PubMed

    Pernot, J M; Brun, H; Pouyet, B; Sergent, M; Phan-Tan-Luu, R

    1993-01-01

    Conditions of microencapsulation by in situ polycondensation, using melamine-formaldehyde as wall material, are influenced by the chemical nature of the core to encapsulate. In our study concerning the encapsulation of a photopolymerizable phase containing an electrically charged compound, it was necessary to modify the experimental process to obtain capsules of good quality. We used the factorial design method of screening by utilization of an asymmetric matrix, according to the collapsing principle of Addleman. The advantage of this method is that it allows determination of the simultaneous influences of the 11 experimental parameters involved in this preparation. The calculation method can be applied to more than two levels for some of the factors. The continuously varying parameters were altered between two extreme levels, chosen to allow encapsulation. For discontinuous factors, such as the molecular weight of the modifying system or nature of the aminoplast, we used the commercially available compounds, respectively three and four kinds. The results of the obtained capsules were determined by comparing microphotographic pictures. With 16 experiments we found four more factors influencing quality of capsules. We also determined the most favourable levels for the other seven parameters. The results allowed us to find optimal conditions in the experimental field. We obtained capsules of a satisfactory quality for this purpose, using only minimum experimentation.

  1. A systematic review investigating the relationship between efficacy and stimulation parameters when using transcutaneous electrical nerve stimulation after knee arthroplasty.

    PubMed

    Beckwée, David; Bautmans, Ivan; Swinnen, Eva; Vermet, Yorick; Lefeber, Nina; Lievens, Pierre; Vaes, Peter

    2014-01-01

    To evaluate the clinical efficacy of transcutaneous electric nerve stimulation in the treatment of postoperative knee arthroplasty pain and to relate these results to the stimulation parameters used. PubMed, Pedro and Web of Knowledge were systematically screened for studies investigating effects of transcutaneous electric nerve stimulation on postoperative knee arthroplasty pain. Studies were screened for their methodological and therapeutical quality. We appraised the influence of the stimulation settings used and indicated whether or not a neurophysiological and/or mechanistic rationale was given for these stimulation settings. A total of 5 articles met the inclusion criteria. In total, 347 patients were investigated. The number of patients who received some form of transcutaneous electric nerve stimulation was 117, and 54 patients received sham transcutaneous electric nerve stimulation. Pain was the primary outcome in all studies. The stimulation settings used in the studies (n = 2) that reported significant effects differed from the others as they implemented a submaximal stimulation intensity. Stimulation parameters were heterogeneous, and only one study provided a rationale for them. This review reveals that an effect of transcutaneous electric nerve stimulation might have been missed due to low methodological and therapeutical quality. Justifying the choice of transcutaneous electric nerve stimulation parameters may improve therapeutical quality.

  2. Filtration, haze and foam characteristics of fermented wort mediated by yeast strain.

    PubMed

    Douglas, P; Meneses, F J; Jiranek, V

    2006-01-01

    To investigate the influence of the choice of yeast strain on the haze, shelf life, filterability and foam quality characteristics of fermented products. Twelve strains were used to ferment a chemically defined wort and hopped ale or stout wort. Fermented products were assessed for foam using the Rudin apparatus, and filterability and haze characteristics using the European Brewing Convention methods, to reveal differences in these parameters as a consequence of the choice of yeast strain and growth medium. Under the conditions used, the choice of strain of Saccharomyces cerevisiae effecting the primary fermentation has an impact on all of the parameters investigated, most notably when the fermentation medium is devoid of macromolecular material. The filtration of fermented products has a large cost implication for many brewers and wine makers, and the haze of the resulting filtrate is a key quality criterion. Also of importance to the quality of beer and some wines is the foaming and head retention of these beverages. The foam characteristics, filterability and potential for haze formation in a fermented product have long been known to be dependant on the raw materials used, as well as other production parameters. The choice of Saccharomyces cerevisiae strain used to ferment has itself been shown here to influence these parameters.

  3. Aquatic environmental assessment of Lake Balaton in the light of physical-chemical water parameters.

    PubMed

    Sebestyén, Vitkor; Németh, József; Juzsakova, Tatjana; Domokos, Endre; Kovács, Zsófia; Rédey, Ákos

    2017-11-01

    One of the issues of the Hungarian Water Management Strategy is the improvement and upgrading of the water of Lake Balaton. The Water Framework Directive (WFD) specifies and sets forth the achievement of the good ecological status. However, the assessment of the water quality of the lake as a complex system requires a comprehensive monitoring and evaluation procedure. Measurements were carried out around the Lake Balaton at ten different locations/sites and 13 physical-chemical parameters were monitored at each measurement site.For the interpretation of the water chemistry parameters the Aquatic Environmental Assessment (AEA) method devised by authors was used for the water body of the Lake Balaton. The AEA method can be used for all types of the water bodies since it is flexible and using individual weighting procedure for the water chemistry parameters comprehensive information can be obtain. The AEA method was compared with existing EIA methods according to a predefined criterion system and proved to be the most suitable tool for evaluating the environmental impacts in our study.On the basis of the results it can be concluded that the status of the quality of studied area on the Lake Balaton can be categorized as proper quality (from the outcome of the ten measurement sites this conclusion was reached at seven sites).

  4. Clinical impact of exercise in patients with peripheral arterial disease.

    PubMed

    Novakovic, Marko; Jug, Borut; Lenasi, Helena

    2017-08-01

    Increasing prevalence, high morbidity and mortality, and decreased health-related quality of life are hallmarks of peripheral arterial disease. About one-third of peripheral arterial disease patients have intermittent claudication with deleterious effects on everyday activities, such as walking. Exercise training improves peripheral arterial disease symptoms and is recommended as first line therapy for peripheral arterial disease. This review examines the effects of exercise training beyond improvements in walking distance, namely on vascular function, parameters of inflammation, activated hemostasis and oxidative stress, and quality of life. Exercise training not only increases walking distance and physiologic parameters in patients with peripheral arterial disease, but also improves the cardiovascular risk profile by helping patients achieve better control of hypertension, hyperglycemia, obesity and dyslipidemia, thus further reducing cardiovascular risk and the prevalence of coexistent atherosclerotic diseases. American guidelines suggest supervised exercise training, performed for a minimum of 30-45 min, at least three times per week, for at least 12 weeks. Walking is the most studied exercise modality and its efficacy in improving cardiovascular parameters in patients with peripheral arterial disease has been extensively proven. As studies have shown that supervised exercise training improves walking performance, cardiovascular parameters and quality of life in patients with peripheral arterial disease, it should be encouraged and more often prescribed.

  5. Impact of Cultivation Conditions, Ethylene Treatment, and Postharvest Storage on Selected Quality and Bioactivity Parameters of Kiwifruit "Hayward" Evaluated by Analytical and Chemometric Methods.

    PubMed

    Park, Yong Seo; Polovka, Martin; Ham, Kyung-Sik Ham; Park, Yang-Kyun; Vearasilp, Suchada; Namieśnik, Jacek; Toledo, Fernando; Arancibia-Avila, Patricia; Gorinstein, Shela

    2016-09-01

    Organic, semiorganic, and conventional "Hayward" kiwifruits, treated with ethylene for 24 h and stored during 10 days, were assessed by UV spectrometry, fluorometry, and chemometrical analysis for changes in selected characteristics of quality (firmness, dry matter and soluble solid contents, pH, and acidity) and bioactivity (concentration of polyphenols via Folin-Ciocalteu and p-hydroxybenzoic acid assays). All of the monitored qualitative parameters and characteristics related to bioactivity were affected either by cultivation practices or by ethylene treatment and storage. Results obtained, supported by statistical evaluation (Friedman two-way ANOVA) and chemometric analysis, clearly proved that the most significant impact on the majority of the evaluated parameters of quality and bioactivity of "Hayward" kiwifruit had the ethylene treatment followed by the cultivation practices and the postharvest storage. Total concentration of polyphenols expressed via p-hydroxybenzoic acid assay exhibited the most significant sensitivity to all three evaluated parameters, reaching a 16.5% increase for fresh organic compared to a conventional control sample. As a result of postharvest storage coupled with ethylene treatment, the difference increased to 26.3%. Three-dimensional fluorescence showed differences in the position of the main peaks and their fluorescence intensity for conventional, semiorganic, and organic kiwifruits in comparison with ethylene nontreated samples.

  6. Assessment of the Eutrophication-Related Environmental Parameters in Two Mediterranean Lakes by Integrating Statistical Techniques and Self-Organizing Maps.

    PubMed

    Hadjisolomou, Ekaterini; Stefanidis, Konstantinos; Papatheodorou, George; Papastergiadou, Evanthia

    2018-03-19

    During the last decades, Mediterranean freshwater ecosystems, especially lakes, have been under severe pressure due to increasing eutrophication and water quality deterioration. In this article, we compared the effectiveness of different data analysis methods by assessing the contribution of environmental parameters to eutrophication processes. For this purpose, principal components analysis (PCA), cluster analysis, and a self-organizing map (SOM) were applied, using water quality data from two transboundary lakes of North Greece. SOM is considered as an advanced and powerful data analysis tool because of its ability to represent complex and nonlinear relationships among multivariate data sets. The results of PCA and cluster analysis agreed with the SOM results, although the latter provided more information because of the visualization abilities regarding the parameters' relationships. Besides nutrients that were found to be a key factor for controlling chlorophyll-a (Chl - a), water temperature was related positively with algal production, while the Secchi disk depth parameter was found to be highly important and negatively related toeutrophic conditions. In general, the SOM results were more specific and allowed direct associations between the water quality variables. Our work showed that SOMs can be used effectively in limnological studies to produce robust and interpretable results, aiding scientists and managers to cope with environmental problems such as eutrophication.

  7. Changes in quality and biochemical parameters in 'Idared' apples during prolonged shelf life and 1-MCP treatment.

    PubMed

    Bizjak, Jan; Slatnar, Ana; Stampar, Franci; Veberic, Robert

    2012-12-01

    In this study, changes in quality and various biochemical parameters of 'Idared' apples during prolonged shelf life period after ultra-low oxygen (ULO) storage were investigated. Additionally, the impact of the postharvest application of 1-methylcyclopropene (1-MCP) on different parameters was evaluated. After the harvest, apples were stored in the ULO storage for 6 months and then exposed to room temperature. Fruit firmness, peel color, and changes in sugars, organic acids and phenolics were monitored during the 3 weeks of shelf life. Malic acid, sugars and firmness decreased at room temperature. However, the color of the apples remained unchanged. The level of citric and ascorbic acid remained constant. Levels of phenolics in the peel increased significantly, whereas remained constant in the pulp of apples. 1-MCP treatment resulted in higher amounts of fructose and glucose, malic acid and greater firmness of apples. However, 1-MCP did not influence the phenolic content, ascorbic acid or color. The results obtained indicate that the content of different health-promoting compounds of apples does not change dramatically at room temperature. At the same time these results suggest that 1-MCP could be useful for maintaining certain quality and biochemical parameters and might extend the shelf life of apples.

  8. Effects of Processing Parameters on the Forming Quality of C-Shaped Thermosetting Composite Laminates in Hot Diaphragm Forming Process

    NASA Astrophysics Data System (ADS)

    Bian, X. X.; Gu, Y. Z.; Sun, J.; Li, M.; Liu, W. P.; Zhang, Z. G.

    2013-10-01

    In this study, the effects of processing temperature and vacuum applying rate on the forming quality of C-shaped carbon fiber reinforced epoxy resin matrix composite laminates during hot diaphragm forming process were investigated. C-shaped prepreg preforms were produced using a home-made hot diaphragm forming equipment. The thickness variations of the preforms and the manufacturing defects after diaphragm forming process, including fiber wrinkling and voids, were evaluated to understand the forming mechanism. Furthermore, both interlaminar slipping friction and compaction behavior of the prepreg stacks were experimentally analyzed for showing the importance of the processing parameters. In addition, autoclave processing was used to cure the C-shaped preforms to investigate the changes of the defects before and after cure process. The results show that the C-shaped prepreg preforms with good forming quality can be achieved through increasing processing temperature and reducing vacuum applying rate, which obviously promote prepreg interlaminar slipping process. The process temperature and forming rate in hot diaphragm forming process strongly influence prepreg interply frictional force, and the maximum interlaminar frictional force can be taken as a key parameter for processing parameter optimization. Autoclave process is effective in eliminating voids in the preforms and can alleviate fiber wrinkles to a certain extent.

  9. The effect of dietary supplementation with dried fruit and vegetable pomaces on production parameters and meat quality in fattening pigs.

    PubMed

    Pieszka, Marek; Szczurek, Paulina; Bederska-Łojewska, Dorota; Migdał, Władysław; Pieszka, Magdalena; Gogol, Piotr; Jagusiak, Wojciech

    2017-04-01

    The presence of biologically active substances in feed mixture is discussed to have beneficial effect on animals' health and products. The purpose of the study was to determine the effect of dietary supplementation with dried apple, chokeberry, black currant, strawberry and carrot pomaces on production parameters and meat quality in fattening pigs. The use of dried pomaces of chokeberry showed tendencies for increased feed intake and reduced fattening period. The dried pomaces had no impact on saturated and monounsaturated fatty acids profile in meat, however in some groups an elevated level of polyunsaturated fatty acids from n-3 family and a decline in total cholesterol level was observed (P≤0.05). The highest oxidative stability and vitamin E content was found after supplementation with black currant (P≤0.05). Summarizing, the used dried pomaces improved several parameters related to meat quality, what might positively influence consumers' health. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  10. Variability of Mercury Content in Coal Matter From Coal Seams of The Upper Silesia Coal Basin

    NASA Astrophysics Data System (ADS)

    Wierzchowski, Krzysztof; Chećko, Jarosław; Pyka, Ireneusz

    2017-12-01

    The process of identifying and documenting the quality parameters of coal, as well as the conditions of coal deposition in the seam, is multi-stage and extremely expensive. The taking and analyzing of seam samples is the method of assessment of the quality and quantity parameters of coals in deep mines. Depending on the method of sampling, it offers quite precise assessment of the quality parameters of potential commercial coals. The main kind of seam samples under consideration are so-called "documentary seam samples", which exclude dirt bands and other seam contaminants. Mercury content in coal matter from the currently accessible and exploited coal seams of the Upper Silesian Coal Basin (USCB) was assessed. It was noted that the mercury content in coal seams decreases with the age of the seam and, to a lesser extent, seam deposition depth. Maps of the variation of mercury content in selected lithostratigraphic units (layers) of the Upper Silesian Coal Basin have been created.

  11. Analysis of Quality-Related Parameters in Mature Kernels of Polygalacturonase Inhibiting Protein (PGIP) Transgenic Bread Wheat Infected with Fusarium graminearum.

    PubMed

    Masci, Stefania; Laino, Paolo; Janni, Michela; Botticella, Ermelinda; Di Carli, Mariasole; Benvenuto, Eugenio; Danieli, Pier Paolo; Lilley, Kathryn S; Lafiandra, Domenico; D'Ovidio, Renato

    2015-04-22

    Fusarium head blight, caused by the fungus Fusarium graminearum, has a detrimental effect on both productivity and qualitative properties of wheat. To evaluate its impact on wheat flour, we compared its effect on quality-related parameters between a transgenic bread wheat line expressing a bean polygalacturonase inhibiting protein (PGIP) and its control line. We have compared metabolic proteins, the amounts of gluten proteins and their relative ratios, starch content, yield, extent of pathogen contamination, and deoxynivalenol (DON) accumulation. These comparisons showed that Fusarium significantly decreases the amount of starch in infected control plants, but not in infected PGIP plants. The flour of PGIP plants contained also a lower amount of pathogen biomass and DON accumulation. Conversely, both gluten and metabolic proteins were not significantly influenced either by the transgene or by fungal infection. These results indicate that the transgenic PGIP expression reduces the level of infection, without changing significantly the wheat seed proteome and other quality-related parameters.

  12. Data on litter quality of host grass plants with and without fungal endophytes.

    PubMed

    Gundel, P E; Helander, M; Garibaldi, L A; Vázquez-de-Aldana, B R; Zabalgogeazcoa, I; Saikkonen, K

    2016-06-01

    Certain Pooideae species form persistent symbiosis with fungal endophytes of Epichloë genus. Although endophytes are known to impact the ecology and evolution of host species, their effects on parameters related with quality of plant biomass has been elusive. This article provides information about parameters related with the quality of plant litter biomass of two important grass species (Schedonorus phoenix and Schedonorus pratensis) affected by the symbiosis with fungal endophytes (Epichloë coenophiala and Epichloë uncinata, respectively). Four population origins of S. phoenix and one of S. pratensis were included. Mineral, biochemical and structural parameters were obtained from three samples per factors combination [species (and population origin)×endophyte]. This data can be potentially used in other studies which, by means of 'data reanalyzing' or meta-analysis, attempt to find generalizations about endophyte effects on host plant litter biomass. The present data is associated with the research article "Role of foliar fungal endophytes on litter decomposition among species and population origins" (Gundel et al., In preparation) [1].

  13. Use of LANDSAT 8 images for depth and water quality assessment of El Guájaro reservoir, Colombia

    NASA Astrophysics Data System (ADS)

    González-Márquez, Luis Carlos; Torres-Bejarano, Franklin M.; Torregroza-Espinosa, Ana Carolina; Hansen-Rodríguez, Ivette Renée; Rodríguez-Gallegos, Hugo B.

    2018-03-01

    The aim of this study was to evaluate the viability of using Landsat 8 spectral images to estimate water quality parameters and depth in El Guájaro Reservoir. On February and March 2015, two samplings were carried out in the reservoir, coinciding with the Landsat 8 images. Turbidity, dissolved oxygen, electrical conductivity, pH and depth were evaluated. Through multiple regression analysis between measured water quality parameters and the reflectance of the pixels corresponding to the sampling stations, statistical models with determination coefficients between 0.6249 and 0.9300 were generated. Results indicate that from a small number of measured parameters we can generate reliable models to estimate the spatial variation of turbidity, dissolved oxygen, pH and depth, as well the temporal variation of electrical conductivity, so models generated from Landsat 8 can be used as a tool to facilitate the environmental, economic and social management of the reservoir.

  14. Rapid monitoring of the fermentation process for Korean traditional rice wine 'Makgeolli' using FT-NIR spectroscopy

    NASA Astrophysics Data System (ADS)

    Kim, Dae-Yong; Cho, Byoung-Kwan

    2015-11-01

    The quality parameters of the Korean traditional rice wine "Makgeolli" were monitored using Fourier transform near-infrared (FT-NIR) spectroscopy with multivariate statistical analysis (MSA) during fermentation. Alcohol, reducing sugar, and titratable acid were the parameters assessed to determine the quality index of fermentation substrates and products. The acquired spectra were analyzed with partial least squares regression (PLSR). The best prediction model for alcohol was obtained with maximum normalization, showing a coefficient of determination (Rp2) of 0.973 and a standard error of prediction (SEP) of 0.760%. In addition, the best prediction model for reducing sugar was obtained with no data preprocessing, with a Rp2 value of 0.945 and a SEP of 1.233%. The prediction of titratable acidity was best with mean normalization, showing a Rp2 value of 0.882 and a SEP of 0.045%. These results demonstrate that FT-NIR spectroscopy can be used for rapid measurements of quality parameters during Makgeolli fermentation.

  15. Water quality assessment and meta model development in Melen watershed - Turkey.

    PubMed

    Erturk, Ali; Gurel, Melike; Ekdal, Alpaslan; Tavsan, Cigdem; Ugurluoglu, Aysegul; Seker, Dursun Zafer; Tanik, Aysegul; Ozturk, Izzet

    2010-07-01

    Istanbul, being one of the highly populated metropolitan areas of the world, has been facing water scarcity since the past decade. Water transfer from Melen Watershed was considered as the most feasible option to supply water to Istanbul due to its high water potential and relatively less degraded water quality. This study consists of two parts. In the first part, water quality data covering 26 parameters from 5 monitoring stations were analyzed and assessed due to the requirements of the "Quality Required of Surface Water Intended for the Abstraction of Drinking Water" regulation. In the second part, a one-dimensional stream water quality model with simple water quality kinetics was developed. It formed a basic design for more advanced water quality models for the watershed. The reason for assessing the water quality data and developing a model was to provide information for decision making on preliminary actions to prevent any further deterioration of existing water quality. According to the water quality assessment at the water abstraction point, Melen River has relatively poor water quality with regard to NH(4)(+), BOD(5), faecal streptococcus, manganese and phenol parameters, and is unsuitable for drinking water abstraction in terms of COD, PO(4)(3-), total coliform, total suspended solids, mercury and total chromium parameters. The results derived from the model were found to be consistent with the water quality assessment. It also showed that relatively high inorganic nitrogen and phosphorus concentrations along the streams are related to diffuse nutrient loads that should be managed together with municipal and industrial wastewaters. Copyright 2010 Elsevier Ltd. All rights reserved.

  16. Sterile Insect Quality

    USDA-ARS?s Scientific Manuscript database

    This chapter discusses the history of the development of quality control tchnology, the principles and philosophy of assessing insect quality, and the relative importance of the various parameters used to assess insect quality in the context of mass-rearing for the SIT. Quality control is most devel...

  17. Adaptive quantization-parameter clip scheme for smooth quality in H.264/AVC.

    PubMed

    Hu, Sudeng; Wang, Hanli; Kwong, Sam

    2012-04-01

    In this paper, we investigate the issues over the smooth quality and the smooth bit rate during rate control (RC) in H.264/AVC. An adaptive quantization-parameter (Q(p)) clip scheme is proposed to optimize the quality smoothness while keeping the bit-rate fluctuation at an acceptable level. First, the frame complexity variation is studied by defining a complexity ratio between two nearby frames. Second, the range of the generated bits is analyzed to prevent the encoder buffer from overflow and underflow. Third, based on the safe range of the generated bits, an optimal Q(p) clip range is developed to reduce the quality fluctuation. Experimental results demonstrate that the proposed Q(p) clip scheme can achieve excellent performance in quality smoothness and buffer regulation.

  18. Effect of aquifer storage and recovery (ASR) on recovered stormwater quality variability.

    PubMed

    Page, D W; Peeters, L; Vanderzalm, J; Barry, K; Gonzalez, D

    2017-06-15

    Aquifer Storage and Recovery (ASR) is increasingly being considered as a means of reusing urban stormwater to supplement available urban water resources. Storage of stormwater in an aquifer has been shown to affect water quality but it has also been claimed that storage will also decrease the stormwater quality variability making for improved predictability and management. This study is the first to document the changes in stormwater quality variability as a result of subsurface storage at four full scale ASR sites using advanced statistical techniques. New methods to examine water quality are required as data is often highly left censored and so traditional measures of variability such as the coefficient of variation are inappropriate. It was observed that for some water quality parameters (most notably E. coli) there was a marked improvement of water quality and a significant decrease in variability at all sites. This means that aquifer storage prior to engineered treatment systems may be advantageous in terms of system design to avoid over engineering. For other parameters such as metal(loids)s and nutrients the trend was less clear due to the numerous processes occurring during storage leading to an increase in variability, especially for geogenic metals and metalloids such as iron and arsenic. Depending upon the specific water quality parameters and end use, use of ASR may not have a dampening effect on stormwater quality variability. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  19. Nonlinear frequency compression: effects on sound quality ratings of speech and music.

    PubMed

    Parsa, Vijay; Scollie, Susan; Glista, Danielle; Seelisch, Andreas

    2013-03-01

    Frequency lowering technologies offer an alternative amplification solution for severe to profound high frequency hearing losses. While frequency lowering technologies may improve audibility of high frequency sounds, the very nature of this processing can affect the perceived sound quality. This article reports the results from two studies that investigated the impact of a nonlinear frequency compression (NFC) algorithm on perceived sound quality. In the first study, the cutoff frequency and compression ratio parameters of the NFC algorithm were varied, and their effect on the speech quality was measured subjectively with 12 normal hearing adults, 12 normal hearing children, 13 hearing impaired adults, and 9 hearing impaired children. In the second study, 12 normal hearing and 8 hearing impaired adult listeners rated the quality of speech in quiet, speech in noise, and music after processing with a different set of NFC parameters. Results showed that the cutoff frequency parameter had more impact on sound quality ratings than the compression ratio, and that the hearing impaired adults were more tolerant to increased frequency compression than normal hearing adults. No statistically significant differences were found in the sound quality ratings of speech-in-noise and music stimuli processed through various NFC settings by hearing impaired listeners. These findings suggest that there may be an acceptable range of NFC settings for hearing impaired individuals where sound quality is not adversely affected. These results may assist an Audiologist in clinical NFC hearing aid fittings for achieving a balance between high frequency audibility and sound quality.

  20. Process analytical technologies (PAT) in freeze-drying of parenteral products.

    PubMed

    Patel, Sajal Manubhai; Pikal, Michael

    2009-01-01

    Quality by Design (QbD), aims at assuring quality by proper design and control, utilizing appropriate Process Analytical Technologies (PAT) to monitor critical process parameters during processing to ensure that the product meets the desired quality attributes. This review provides a comprehensive list of process monitoring devices that can be used to monitor critical process parameters and will focus on a critical review of the viability of the PAT schemes proposed. R&D needs in PAT for freeze-drying have also been addressed with particular emphasis on batch techniques that can be used on all the dryers independent of the dryer scale.

  1. Prevalence of vitamin D insufficiency among adolescents and its correlation with bone parameters using high-resolution peripheral quantitative computed tomography.

    PubMed

    Cheung, T F; Cheuk, K Y; Yu, F W P; Hung, V W Y; Ho, C S; Zhu, T Y; Ng, B K W; Lee, K M; Qin, L; Ho, S S Y; Wong, G W K; Cheng, J C Y; Lam, T P

    2016-08-01

    Vitamin D deficiency and insufficiency are highly prevalent among adolescents in Hong Kong, which is a sub-tropical city with ample sunshine. Vitamin D level is significantly correlated with key bone density and bone quality parameters. Further interventional studies are warranted to define the role of vitamin D supplementation for improvement of bone health among adolescents. The relationship between bone quality parameters and vitamin D (Vit-D) status remains undefined among adolescents. The aims of this study were to evaluate Vit-D status and its association with both bone density and bone quality parameters among adolescents. Three hundred thirty-three girls and 230 boys (12-16 years old) with normal health were recruited in summer and winter separately from local schools. Serum 25(OH) Vit-D level, bone density and quality parameters by Dual Energy X-ray Absorptiometry (DXA) and High-Resolution peripheral Quantitative Computed Tomography (HR-pQCT), dietary calcium intake, and physical activity level were assessed. Sixty-four point seven percent and 11.4 % of subjects were insufficient [25 ≤ 25(OH)Vit-D ≤ 50 nmol/L] and deficient [25(OH)Vit-D < 25 nmol/L] in Vit-D, respectively. The mean level of serum 25(OH)Vit-D in summer was significantly higher than that in winter (44.7 ± 13.6 and 35.9 ± 12.6 nmol/L, respectively) without obvious gender difference. In girls, areal bone mineral density (aBMD) and bone mineral content (BMC) of bilateral femoral necks, cortical area, cortical thickness, total volumetric bone mineral density (vBMD), and trabecular thickness were significantly correlated with 25(OH)Vit-D levels. In boys, aBMD of bilateral femoral necks, BMC of the dominant femoral neck, cortical area, cortical thickness, total vBMD, trabecular vBMD, BV/TV, and trabecular separation were significantly correlated with 25(OH)Vit-D levels. Vit-D insufficiency was highly prevalent among adolescents in Hong Kong with significant correlation between Vit-D levels and key bone density and bone quality parameters being detected in this study. Given that this is a cross-sectional study and causality relationship cannot be inferred, further interventional studies investigating the role of Vit-D supplementation on improving bone health among adolescents are warranted.

  2. Assessment and modeling of the groundwater hydrogeochemical quality parameters via geostatistical approaches

    NASA Astrophysics Data System (ADS)

    Karami, Shawgar; Madani, Hassan; Katibeh, Homayoon; Fatehi Marj, Ahmad

    2018-03-01

    Geostatistical methods are one of the advanced techniques used for interpolation of groundwater quality data. The results obtained from geostatistics will be useful for decision makers to adopt suitable remedial measures to protect the quality of groundwater sources. Data used in this study were collected from 78 wells in Varamin plain aquifer located in southeast of Tehran, Iran, in 2013. Ordinary kriging method was used in this study to evaluate groundwater quality parameters. According to what has been mentioned in this paper, seven main quality parameters (i.e. total dissolved solids (TDS), sodium adsorption ratio (SAR), electrical conductivity (EC), sodium (Na+), total hardness (TH), chloride (Cl-) and sulfate (SO4 2-)), have been analyzed and interpreted by statistical and geostatistical methods. After data normalization by Nscore method in WinGslib software, variography as a geostatistical tool to define spatial regression was compiled and experimental variograms were plotted by GS+ software. Then, the best theoretical model was fitted to each variogram based on the minimum RSS. Cross validation method was used to determine the accuracy of the estimated data. Eventually, estimation maps of groundwater quality were prepared in WinGslib software and estimation variance map and estimation error map were presented to evaluate the quality of estimation in each estimated point. Results showed that kriging method is more accurate than the traditional interpolation methods.

  3. Optimization of operator and physical parameters for laser welding of dental materials.

    PubMed

    Bertrand, C; le Petitcorps, Y; Albingre, L; Dupuis, V

    2004-04-10

    Interactions between lasers and materials are very complex phenomena. The success of laser welding procedures in dental metals depends on the operator's control of many parameters. The aims of this study were to evaluate factors relating to the operator's dexterity and the choice of the welding parameters (power, pulse duration and therefore energy), which are recognized determinants of weld quality. In vitro laboratory study. FeNiCr dental drawn wires were chosen for these experiments because their properties are well known. Different diameters of wires were laser welded, then tested in tension and compared to the control material as extruded, in order to evaluate the quality of the welding. Scanning electron microscopy of the fractured zone and micrograph observations perpendicular and parallel to the wire axis were also conducted in order to analyse the depth penetration and the quality of the microstructure. Additionally, the micro-hardness (Vickers type) was measured both in the welded and the heat-affected zones and then compared to the non-welded alloy. Adequate combination of energy and pulse duration with the power set in the range between 0.8 to 1 kW appears to improve penetration depth of the laser beam and success of the welding procedure. Operator skill is also an important variable. The variation in laser weld quality in dental FeNiCr wires attributable to operator skill can be minimized by optimization of the physical welding parameters.

  4. Quality, stability and radical scavenging activity of olive oils after Chétoui olives (Olea europaea L.) storage under modified atmospheres.

    PubMed

    Ben Yahia, L; Baccouri, B; Ouni, Y; Hamdi, S

    2012-08-01

    At the industrial scale, the major source of olive oil deterioration is the poor handling of the raw material during the time separating harvesting from processing. The objective of this work was to verify the effect of modified atmospheres and cold storage in relation to quality parameters of the extracted oils. Olives (cv Chétoui) intended for oil extraction, were stored for 21 days at two different temperatures (ambient temperature 14 ± 2 °C and 5 °C) and under two different modified atmospheres 21% O₂ - 0% CO₂ and 2% O₂ - 5% CO₂. Oils quality was ascertained with analytical parameters: free fatty acids, peroxide value, K₂₃₂, K₂₇₀ as suggested by European regulation. Oxidative stability, total phenols content, radical scavenging activity and fatty acids composition were carried out in order to measure the hydrolytic and oxidative degradation of oils. Olive oils quality parameters were significantly affected by treatments with especially a beneficial effect on primary oxidation indicators and free acidity. Most efficient treatments, with regard to oils phenolic content and involved parameters, were 21% O₂ - 0% CO₂ at ambient temperature (636.25 mg ca/kg) and 2% O₂ - 5% CO₂ under 5 °C (637.50 mg ca/kg). Those two treatments improved individually oil samples phenolic content of 25% but not at the same storage period.

  5. Fluorescence-based multi-parameter approach to characterize dynamics of organic carbon, faecal bacteria and particles at alpine karst springs.

    PubMed

    Frank, Simon; Goeppert, Nadine; Goldscheider, Nico

    2018-02-15

    Karst springs, especially in alpine regions, are important for drinking water supply but also vulnerable to contamination, especially after rainfall events. This high variability of water quality requires rapid quantification of contamination parameters. Here, we used a fluorescence-based multi-parameter approach to characterize the dynamics of organic carbon, faecal bacteria, and particles at three alpine karst springs. We used excitation emission matrices (EEMs) to identify fluorescent dissolved organic material (FDOM). At the first system, peak A fluorescence and total organic carbon (TOC) were strongly correlated (Spearman's r s of 0.949), indicating that a large part of the organic matter is related to humic-like substances. Protein-like fluorescence and cultivation-based determination of coliform bacteria also had a significant correlation with r s =0.734, indicating that protein-like fluorescence is directly related to faecal pollution. At the second system, which has two spring outlets, the absolute values of all measured water-quality parameters were lower; there was a significant correlation between TOC and humic-like fluorescence (r s =0.588-0.689) but coliform bacteria and protein-like fluorescence at these two springs were not correlated. Additionally, there was a strong correlation (r s =0.571-0.647) between small particle fractions (1.0 and 2.0μm), a secondary turbidity peak and bacteria. At one of these springs, discharge was constant despite the reaction of all other parameters to the rainfall event. Our results demonstrated that i) all three springs showed fast and marked responses of all investigated water-quality parameters after rain events; ii) a constant discharge does not necessarily mean constant water quality; iii) at high contamination levels, protein-like fluorescence is a good indicator of bacterial contamination, while at low contamination levels no correlation between protein-like fluorescence and bacterial values was detected; and iv) a combination of fluorescence measurements and particle-size analysis is a promising approach for a rapid assessment of organic contamination, especially relative to time-consuming conventional bacterial determination methods. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Port wine oxidation management: a multiparametric kinetic approach.

    PubMed

    Martins, Rui Costa; Monforte, Ana Rita; Silva Ferreira, António

    2013-06-05

    Port wine is a flagship fortified wine of Portugal, which undergoes a particularly long aging period, developing a dynamic sensory profile over time, responsible for several wine categories, which is dependent upon the type of aging (bottle or barrel). Therefore, the quality of the product is dependent upon the chemical mechanisms occurring during the aging process, such as oxidation or Maillard reactions. To attain the desired quality management, it is necessary to understand how technological parameters, such as temperature or oxygen exposure, affect the kinetics of the formation of key odorants, such as sotolon. There is a lack of information about the impact of the storage conditions (oxygen and temperature) on Port wine quality. In this study, the effect of these two parameters were investigated to increase the knowledge database concerning aging management of Port wines. It was found that sotolon formation is highly dependent upon oxygen and temperature. There is however a synergistic effect between these two parameters that could significantly increase the concentration. The kinetic parameters of oxygen, sotolon, and other compounds related to Port aging (cis- and trans-5-hydroxy-2-methyl-1,3-dioxan, 2-furfural, 5-hydroxy-methyl-furfural, and 5-methyl-furfural) are also reported. Kinetic models with Monte Carlo simulations, where the oxygen permeability dispersion and temperature are the parameters under evaluation, were applied. On the basis of the modeling predictions, it would seem that the temperature of a cellar would have a more significant impact on the Port wines stored in containers where the oxygen intake is higher (barrels) when compared to containers with low oxygen permeability (bottles using cork stoppers).

  7. Freezability and semen parameters in candidates of sperm bank donors: 1992-2010.

    PubMed

    Yogev, Leah; Paz, Gedalia; Kleiman, Sandra E; Shabtai, Esther; Gamzu, Ronni; Botchan, Amnon; Lehavi, Ofer; Yavetz, Haim; Hauser, Ron

    2012-01-01

    There has been considerable concern worldwide about possible semen quality deterioration over the last 2 decades. The aim of this study was to evaluate freezability and semen quality of healthy young males during the years 1992-2010. A total of 1211 young (20-32 years old) candidates for sperm bank donation were recruited into the study with no exclusion criteria. They were instructed to observe 2 to 3 days of abstinence from sexual activity, and most of them supplied 2 specimens each. Average values of the various semen parameters, including freezing survival, were calculated for each participant. The change in different semen parameters over years, according to yearly and monthly average temperatures, was evaluated by SAS PROC SURVEYREG analysis. During that period, there were significant increases in motility and vitality percentages, as well as in the percentage of thawed sperm motility. The parameters of volume, concentration, normal morphology, total count, and total motile count showed a significant decrease with years (P < .01). The significant increase in average yearly temperature (P < .004) had limited, nonsignificant association with any of the semen variables. However, average monthly temperature contributed significantly to the trend of semen quality parameters (ie, specimen volume, concentration, percentage of normal morphology, and thawed motility). To the best of our knowledge, this is the first demonstration of the occurrence of an improvement in percent thawed motility over the years, and its significance lies in enabling a higher proportion of sperm bank candidates to be suitable for donation. It is suggested that the global warming phenomenon might have only partial contribution to semen variable changes over the years.

  8. Operational use of open satellite data for marine water quality monitoring

    NASA Astrophysics Data System (ADS)

    Symeonidis, Panagiotis; Vakkas, Theodoros

    2017-09-01

    The purpose of this study was to develop an operational platform for marine water quality monitoring using near real time satellite data. The developed platform utilizes free and open satellite data available from different data sources like COPERNICUS, the European Earth Observation Initiative, or NASA, from different satellites and instruments. The quality of the marine environment is operationally evaluated using parameters like chlorophyll-a concentration, water color and Sea Surface Temperature (SST). For each parameter, there are more than one dataset available, from different data sources or satellites, to allow users to select the most appropriate dataset for their area or time of interest. The above datasets are automatically downloaded from the data provider's services and ingested to the central, spatial engine. The spatial data platform uses the Postgresql database with the PostGIS extension for spatial data storage and Geoserver for the provision of the spatial data services. The system provides daily, 10 days and monthly maps and time series of the above parameters. The information is provided using a web client which is based on the GET SDI PORTAL, an easy to use and feature rich geospatial visualization and analysis platform. The users can examine the temporal variation of the parameters using a simple time animation tool. In addition, with just one click on the map, the system provides an interactive time series chart for any of the parameters of the available datasets. The platform can be offered as Software as a Service (SaaS) to any area in the Mediterranean region.

  9. Optimization of process parameters for a quasi-continuous tablet coating system using design of experiments.

    PubMed

    Cahyadi, Christine; Heng, Paul Wan Sia; Chan, Lai Wah

    2011-03-01

    The aim of this study was to identify and optimize the critical process parameters of the newly developed Supercell quasi-continuous coater for optimal tablet coat quality. Design of experiments, aided by multivariate analysis techniques, was used to quantify the effects of various coating process conditions and their interactions on the quality of film-coated tablets. The process parameters varied included batch size, inlet temperature, atomizing pressure, plenum pressure, spray rate and coating level. An initial screening stage was carried out using a 2(6-1(IV)) fractional factorial design. Following these preliminary experiments, optimization study was carried out using the Box-Behnken design. Main response variables measured included drug-loading efficiency, coat thickness variation, and the extent of tablet damage. Apparent optimum conditions were determined by using response surface plots. The process parameters exerted various effects on the different response variables. Hence, trade-offs between individual optima were necessary to obtain the best compromised set of conditions. The adequacy of the optimized process conditions in meeting the combined goals for all responses was indicated by the composite desirability value. By using response surface methodology and optimization, coating conditions which produced coated tablets of high drug-loading efficiency, low incidences of tablet damage and low coat thickness variation were defined. Optimal conditions were found to vary over a large spectrum when different responses were considered. Changes in processing parameters across the design space did not result in drastic changes to coat quality, thereby demonstrating robustness in the Supercell coating process. © 2010 American Association of Pharmaceutical Scientists

  10. Warpage optimization on a mobile phone case using response surface methodology (RSM)

    NASA Astrophysics Data System (ADS)

    Lee, X. N.; Fathullah, M.; Shayfull, Z.; Nasir, S. M.; Hazwan, M. H. M.; Shazzuan, S.

    2017-09-01

    Plastic injection moulding is a popular manufacturing method not only it is reliable, but also efficient and cost saving. It able to produce plastic part with detailed features and complex geometry. However, defects in injection moulding process degrades the quality and aesthetic of the injection moulded product. The most common defect occur in the process is warpage. Inappropriate process parameter setting of injection moulding machine is one of the reason that leads to the occurrence of warpage. The aims of this study were to improve the quality of injection moulded part by investigating the optimal parameters in minimizing warpage using Response Surface Methodology (RSM). Subsequent to this, the most significant parameter was identified and recommended parameters setting was compared with the optimized parameter setting using RSM. In this research, the mobile phone case was selected as case study. The mould temperature, melt temperature, packing pressure, packing time and cooling time were selected as variables whereas warpage in y-direction was selected as responses in this research. The simulation was carried out by using Autodesk Moldflow Insight 2012. In addition, the RSM was performed by using Design Expert 7.0. The warpage in y direction recommended by RSM were reduced by 70 %. RSM performed well in solving warpage issue.

  11. Radiofrequency for the treatment of skin laxity: mith or truth*

    PubMed Central

    de Araújo, Angélica Rodrigues; Soares, Viviane Pinheiro Campos; da Silva, Fernanda Souza; Moreira, Tatiane da Silva

    2015-01-01

    The nonablative radiofrequency is a procedure commonly used for the treatment of skin laxity from an increase in tissue temperature. The goal is to induce thermal damage to thus stimulate neocollagenesis in deep layers of the skin and subcutaneous tissue. However, many of these devices haven't been tested and their parameters are still not accepted by the scientific community. Because of this, it is necessary to review the literature regarding the physiological effects and parameters for application of radiofrequency and methodological quality and level of evidence of studies. A literature search was performed in MEDLINE, PEDro, SciELO, PubMed, LILACS and CAPES and experimental studies in humans, which used radiofrequency devices as treatment for facial or body laxity, were selected. The results showed that the main physiological effect is to stimulate collagen synthesis. There was no homogeneity between studies in relation to most of the parameters used and the methodological quality of studies and level of evidence for using radiofrequency are low. This fact complicates the determination of effective parameters for clinical use of this device in the treatment of skin laxity. The analyzed studies suggest that radiofrequency is effective, however the physiological mechanisms and the required parameters are not clear in the literature. PMID:26560216

  12. Application of Time-series Model to Predict Groundwater Quality Parameters for Agriculture: (Plain Mehran Case Study)

    NASA Astrophysics Data System (ADS)

    Mehrdad Mirsanjari, Mir; Mohammadyari, Fatemeh

    2018-03-01

    Underground water is regarded as considerable water source which is mainly available in arid and semi arid with deficient surface water source. Forecasting of hydrological variables are suitable tools in water resources management. On the other hand, time series concepts is considered efficient means in forecasting process of water management. In this study the data including qualitative parameters (electrical conductivity and sodium adsorption ratio) of 17 underground water wells in Mehran Plain has been used to model the trend of parameters change over time. Using determined model, the qualitative parameters of groundwater is predicted for the next seven years. Data from 2003 to 2016 has been collected and were fitted by AR, MA, ARMA, ARIMA and SARIMA models. Afterward, the best model is determined using information criterion or Akaike (AIC) and correlation coefficient. After modeling parameters, the map of agricultural land use in 2016 and 2023 were generated and the changes between these years were studied. Based on the results, the average of predicted SAR (Sodium Adsorption Rate) in all wells in the year 2023 will increase compared to 2016. EC (Electrical Conductivity) average in the ninth and fifteenth holes and decreases in other wells will be increased. The results indicate that the quality of groundwater for Agriculture Plain Mehran will decline in seven years.

  13. Parametric study of waste chicken fat catalytic chemical vapour deposition for controlled synthesis of vertically aligned carbon nanotubes

    NASA Astrophysics Data System (ADS)

    Suriani, A. B.; Dalila, A. R.; Mohamed, A.; Rosmi, M. S.; Mamat, M. H.; Malek, M. F.; Ahmad, M. K.; Hashim, N.; Isa, I. M.; Soga, T.; Tanemura, M.

    2016-12-01

    High-quality vertically aligned carbon nanotubes (VACNTs) were synthesised using ferrocene-chicken oil mixture utilising a thermal chemical vapour deposition (TCVD) method. Reaction parameters including vaporisation temperature, catalyst concentration and synthesis time were examined for the first time to investigate their influence on the growth of VACNTs. Analysis via field emission scanning electron microscopy and micro-Raman spectroscopy revealed that the growth rate, diameter and crystallinity of VACNTs depend on the varied synthesis parameters. Vaporisation temperature of 570°C, catalyst concentration of 5.33 wt% and synthesis time of 60 min were considered as optimum parameters for the production of VACNTs from waste chicken fat. These parameters are able to produce VACNTs with small diameters in the range of 15-30 nm and good quality (ID/IG 0.39 and purity 76%) which were comparable to those synthesised using conventional carbon precursor. The low turn on and threshold fields of VACNTs synthesised using optimum parameters indicated that the VACNTs synthesised using waste chicken fat are good candidate for field electron emitter. The result of this study therefore can be used to optimise the growth and production of VACNTs from waste chicken fat in a large scale for field emission application.

  14. Evaluation of the AnnAGNPS Model for Predicting Runoff and Nutrient Export in a Typical Small Watershed in the Hilly Region of Taihu Lake.

    PubMed

    Luo, Chuan; Li, Zhaofu; Li, Hengpeng; Chen, Xiaomin

    2015-09-02

    The application of hydrological and water quality models is an efficient approach to better understand the processes of environmental deterioration. This study evaluated the ability of the Annualized Agricultural Non-Point Source (AnnAGNPS) model to predict runoff, total nitrogen (TN) and total phosphorus (TP) loading in a typical small watershed of a hilly region near Taihu Lake, China. Runoff was calibrated and validated at both an annual and monthly scale, and parameter sensitivity analysis was performed for TN and TP before the two water quality components were calibrated. The results showed that the model satisfactorily simulated runoff at annual and monthly scales, both during calibration and validation processes. Additionally, results of parameter sensitivity analysis showed that the parameters Fertilizer rate, Fertilizer organic, Canopy cover and Fertilizer inorganic were more sensitive to TN output. In terms of TP, the parameters Residue mass ratio, Fertilizer rate, Fertilizer inorganic and Canopy cover were the most sensitive. Based on these sensitive parameters, calibration was performed. TN loading produced satisfactory results for both the calibration and validation processes, whereas the performance of TP loading was slightly poor. The simulation results showed that AnnAGNPS has the potential to be used as a valuable tool for the planning and management of watersheds.

  15. Air Pollution and Quality of Sperm: A Meta-Analysis

    PubMed Central

    Fathi Najafi, Tahereh; Latifnejad Roudsari, Robab; Namvar, Farideh; Ghavami Ghanbarabadi, Vahid; Hadizadeh Talasaz, Zahra; Esmaeli, Mahin

    2015-01-01

    Context: Air pollution is common in all countries and affects reproductive functions in men and women. It particularly impacts sperm parameters in men. This meta-analysis aimed to examine the impact of air pollution on the quality of sperm. Evidence Acquisition: The scientific databases of Medline, PubMed, Scopus, Google scholar, Cochrane Library, and Elsevier were searched to identify relevant articles published between 1978 to 2013. In the first step, 76 articles were selected. These studies were ecological correlation, cohort, retrospective, cross-sectional, and case control ones that were found through electronic and hand search of references about air pollution and male infertility. The outcome measurement was the change in sperm parameters. A total of 11 articles were ultimately included in a meta-analysis to examine the impact of air pollution on sperm parameters. The authors applied meta-analysis sheets from Cochrane library, then data extraction, including mean and standard deviation of sperm parameters were calculated and finally their confidence interval (CI) were compared to CI of standard parameters. Results: The CI for pooled means were as follows: 2.68 ± 0.32 for ejaculation volume (mL), 62.1 ± 15.88 for sperm concentration (million per milliliter), 39.4 ± 5.52 for sperm motility (%), 23.91 ± 13.43 for sperm morphology (%) and 49.53 ± 11.08 for sperm count. Conclusions: The results of this meta-analysis showed that air pollution reduces sperm motility, but has no impact on the other sperm parameters of spermogram. PMID:26023349

  16. Air pollution and quality of sperm: a meta-analysis.

    PubMed

    Fathi Najafi, Tahereh; Latifnejad Roudsari, Robab; Namvar, Farideh; Ghavami Ghanbarabadi, Vahid; Hadizadeh Talasaz, Zahra; Esmaeli, Mahin

    2015-04-01

    Air pollution is common in all countries and affects reproductive functions in men and women. It particularly impacts sperm parameters in men. This meta-analysis aimed to examine the impact of air pollution on the quality of sperm. The scientific databases of Medline, PubMed, Scopus, Google scholar, Cochrane Library, and Elsevier were searched to identify relevant articles published between 1978 to 2013. In the first step, 76 articles were selected. These studies were ecological correlation, cohort, retrospective, cross-sectional, and case control ones that were found through electronic and hand search of references about air pollution and male infertility. The outcome measurement was the change in sperm parameters. A total of 11 articles were ultimately included in a meta-analysis to examine the impact of air pollution on sperm parameters. The authors applied meta-analysis sheets from Cochrane library, then data extraction, including mean and standard deviation of sperm parameters were calculated and finally their confidence interval (CI) were compared to CI of standard parameters. The CI for pooled means were as follows: 2.68 ± 0.32 for ejaculation volume (mL), 62.1 ± 15.88 for sperm concentration (million per milliliter), 39.4 ± 5.52 for sperm motility (%), 23.91 ± 13.43 for sperm morphology (%) and 49.53 ± 11.08 for sperm count. The results of this meta-analysis showed that air pollution reduces sperm motility, but has no impact on the other sperm parameters of spermogram.

  17. Modeling the relationship between landscape characteristics and water quality in a typical highly intensive agricultural small watershed, Dongting lake basin, south central China.

    PubMed

    Li, Hongqing; Liu, Liming; Ji, Xiang

    2015-03-01

    Understanding the relationship between landscape characteristics and water quality is critically important for estimating pollution potential and reducing pollution risk. Therefore, this study examines the relationship between landscape characteristics and water quality at both spatial and temporal scales. The study took place in the Jinjing River watershed in 2010; seven landscape types and four water quality pollutions were chosen as analysis parameters. Three different buffer areas along the river were drawn to analyze the relationship as a function of spatial scale. The results of a Pearson's correlation coefficient analysis suggest that "source" landscape, namely, tea gardens, residential areas, and paddy lands, have positive effects on water quality parameters, while forests exhibit a negative influence on water quality parameters because they represent a "sink" landscape and the sub-watershed level is identified as a suitable scale. Using the principal component analysis, tea gardens, residential areas, paddy lands, and forests were identified as the main landscape index. A stepwise multiple regression analysis was employed to model the relationship between landscape characteristics and water quality for each season. The results demonstrate that both landscape composition and configuration affect water quality. In summer and winter, the landscape metrics explained approximately 80.7 % of the variance in the water quality variables, which was higher than that for spring and fall (60.3 %). This study can help environmental managers to understand the relationships between landscapes and water quality and provide landscape ecological approaches for water quality control and land use management.

  18. The Contribution of GIS to Display and Analyze the Water Quality Data Collected by a Wireless Sensor Network: Case of Bouregreg Catchment, Morocco

    NASA Astrophysics Data System (ADS)

    Boubakri, S.; Rhinane, H.

    2017-11-01

    The monitoring of water quality is, in most cases, managed in the laboratory and not on real time bases. Besides this process being lengthy, it doesn't provide the required specifications to describe the evolution of the quality parameters that are of interest. This study presents the integration of Geographic Information Systems (GIS) with wireless sensor networks (WSN) aiming to create a system able to detect the parameters like temperature, salinity and conductivity in a Moroccan catchment scale and transmit information to the support station. This Information is displayed and evaluated in a GIS using maps and spatial dashboard to monitor the water quality in real time.

  19. Minimal residual method provides optimal regularization parameter for diffuse optical tomography

    NASA Astrophysics Data System (ADS)

    Jagannath, Ravi Prasad K.; Yalavarthy, Phaneendra K.

    2012-10-01

    The inverse problem in the diffuse optical tomography is known to be nonlinear, ill-posed, and sometimes under-determined, requiring regularization to obtain meaningful results, with Tikhonov-type regularization being the most popular one. The choice of this regularization parameter dictates the reconstructed optical image quality and is typically chosen empirically or based on prior experience. An automated method for optimal selection of regularization parameter that is based on regularized minimal residual method (MRM) is proposed and is compared with the traditional generalized cross-validation method. The results obtained using numerical and gelatin phantom data indicate that the MRM-based method is capable of providing the optimal regularization parameter.

  20. Minimal residual method provides optimal regularization parameter for diffuse optical tomography.

    PubMed

    Jagannath, Ravi Prasad K; Yalavarthy, Phaneendra K

    2012-10-01

    The inverse problem in the diffuse optical tomography is known to be nonlinear, ill-posed, and sometimes under-determined, requiring regularization to obtain meaningful results, with Tikhonov-type regularization being the most popular one. The choice of this regularization parameter dictates the reconstructed optical image quality and is typically chosen empirically or based on prior experience. An automated method for optimal selection of regularization parameter that is based on regularized minimal residual method (MRM) is proposed and is compared with the traditional generalized cross-validation method. The results obtained using numerical and gelatin phantom data indicate that the MRM-based method is capable of providing the optimal regularization parameter.

  1. The Effect of Fuel Quality on Carbon Dioxide and Nitrogen Oxide Emissions, While Burning Biomass and RDF

    NASA Astrophysics Data System (ADS)

    Kalnacs, J.; Bendere, R.; Murasovs, A.; Arina, D.; Antipovs, A.; Kalnacs, A.; Sprince, L.

    2018-02-01

    The article analyses the variations in carbon dioxide emission factor depending on parameters characterising biomass and RDF (refuse-derived fuel). The influence of moisture, ash content, heat of combustion, carbon and nitrogen content on the amount of emission factors has been reviewed, by determining their average values. The options for the improvement of the fuel to result in reduced emissions of carbon dioxide and nitrogen oxide have been analysed. Systematic measurements of biomass parameters have been performed, by determining their average values, seasonal limits of variations in these parameters and their mutual relations. Typical average values of RDF parameters and limits of variations have been determined.

  2. An Optimized Trajectory Planning for Welding Robot

    NASA Astrophysics Data System (ADS)

    Chen, Zhilong; Wang, Jun; Li, Shuting; Ren, Jun; Wang, Quan; Cheng, Qunchao; Li, Wentao

    2018-03-01

    In order to improve the welding efficiency and quality, this paper studies the combined planning between welding parameters and space trajectory for welding robot and proposes a trajectory planning method with high real-time performance, strong controllability and small welding error. By adding the virtual joint at the end-effector, the appropriate virtual joint model is established and the welding process parameters are represented by the virtual joint variables. The trajectory planning is carried out in the robot joint space, which makes the control of the welding process parameters more intuitive and convenient. By using the virtual joint model combined with the B-spline curve affine invariant, the welding process parameters are indirectly controlled by controlling the motion curve of the real joint. To solve the optimal time solution as the goal, the welding process parameters and joint space trajectory joint planning are optimized.

  3. Genetic algorithm based input selection for a neural network function approximator with applications to SSME health monitoring

    NASA Technical Reports Server (NTRS)

    Peck, Charles C.; Dhawan, Atam P.; Meyer, Claudia M.

    1991-01-01

    A genetic algorithm is used to select the inputs to a neural network function approximator. In the application considered, modeling critical parameters of the space shuttle main engine (SSME), the functional relationship between measured parameters is unknown and complex. Furthermore, the number of possible input parameters is quite large. Many approaches have been used for input selection, but they are either subjective or do not consider the complex multivariate relationships between parameters. Due to the optimization and space searching capabilities of genetic algorithms they were employed to systematize the input selection process. The results suggest that the genetic algorithm can generate parameter lists of high quality without the explicit use of problem domain knowledge. Suggestions for improving the performance of the input selection process are also provided.

  4. Multi-Response Optimization of WEDM Process Parameters Using Taguchi Based Desirability Function Analysis

    NASA Astrophysics Data System (ADS)

    Majumder, Himadri; Maity, Kalipada

    2018-03-01

    Shape memory alloy has a unique capability to return to its original shape after physical deformation by applying heat or thermo-mechanical or magnetic load. In this experimental investigation, desirability function analysis (DFA), a multi-attribute decision making was utilized to find out the optimum input parameter setting during wire electrical discharge machining (WEDM) of Ni-Ti shape memory alloy. Four critical machining parameters, namely pulse on time (TON), pulse off time (TOFF), wire feed (WF) and wire tension (WT) were taken as machining inputs for the experiments to optimize three interconnected responses like cutting speed, kerf width, and surface roughness. Input parameter combination TON = 120 μs., TOFF = 55 μs., WF = 3 m/min. and WT = 8 kg-F were found to produce the optimum results. The optimum process parameters for each desired response were also attained using Taguchi’s signal-to-noise ratio. Confirmation test has been done to validate the optimum machining parameter combination which affirmed DFA was a competent approach to select optimum input parameters for the ideal response quality for WEDM of Ni-Ti shape memory alloy.

  5. An Improved Method to Control the Critical Parameters of a Multivariable Control System

    NASA Astrophysics Data System (ADS)

    Subha Hency Jims, P.; Dharmalingam, S.; Wessley, G. Jims John

    2017-10-01

    The role of control systems is to cope with the process deficiencies and the undesirable effect of the external disturbances. Most of the multivariable processes are highly iterative and complex in nature. Aircraft systems, Modern Power Plants, Refineries, Robotic systems are few such complex systems that involve numerous critical parameters that need to be monitored and controlled. Control of these important parameters is not only tedious and cumbersome but also is crucial from environmental, safety and quality perspective. In this paper, one such multivariable system, namely, a utility boiler has been considered. A modern power plant is a complex arrangement of pipework and machineries with numerous interacting control loops and support systems. In this paper, the calculation of controller parameters based on classical tuning concepts has been presented. The controller parameters thus obtained and employed has controlled the critical parameters of a boiler during fuel switching disturbances. The proposed method can be applied to control the critical parameters like elevator, aileron, rudder, elevator trim rudder and aileron trim, flap control systems of aircraft systems.

  6. Uncertainty Analysis in 3D Equilibrium Reconstruction

    DOE PAGES

    Cianciosa, Mark R.; Hanson, James D.; Maurer, David A.

    2018-02-21

    Reconstruction is an inverse process where a parameter space is searched to locate a set of parameters with the highest probability of describing experimental observations. Due to systematic errors and uncertainty in experimental measurements, this optimal set of parameters will contain some associated uncertainty. This uncertainty in the optimal parameters leads to uncertainty in models derived using those parameters. V3FIT is a three-dimensional (3D) equilibrium reconstruction code that propagates uncertainty from the input signals, to the reconstructed parameters, and to the final model. Here in this paper, we describe the methods used to propagate uncertainty in V3FIT. Using the resultsmore » of whole shot 3D equilibrium reconstruction of the Compact Toroidal Hybrid, this propagated uncertainty is validated against the random variation in the resulting parameters. Two different model parameterizations demonstrate how the uncertainty propagation can indicate the quality of a reconstruction. As a proxy for random sampling, the whole shot reconstruction results in a time interval that will be used to validate the propagated uncertainty from a single time slice.« less

  7. Uncertainty Analysis in 3D Equilibrium Reconstruction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cianciosa, Mark R.; Hanson, James D.; Maurer, David A.

    Reconstruction is an inverse process where a parameter space is searched to locate a set of parameters with the highest probability of describing experimental observations. Due to systematic errors and uncertainty in experimental measurements, this optimal set of parameters will contain some associated uncertainty. This uncertainty in the optimal parameters leads to uncertainty in models derived using those parameters. V3FIT is a three-dimensional (3D) equilibrium reconstruction code that propagates uncertainty from the input signals, to the reconstructed parameters, and to the final model. Here in this paper, we describe the methods used to propagate uncertainty in V3FIT. Using the resultsmore » of whole shot 3D equilibrium reconstruction of the Compact Toroidal Hybrid, this propagated uncertainty is validated against the random variation in the resulting parameters. Two different model parameterizations demonstrate how the uncertainty propagation can indicate the quality of a reconstruction. As a proxy for random sampling, the whole shot reconstruction results in a time interval that will be used to validate the propagated uncertainty from a single time slice.« less

  8. A Measure of Quality

    ERIC Educational Resources Information Center

    Environmental Science and Technology, 1976

    1976-01-01

    Recent national surveys conducted by the Council on Environmental Quality and others uncovered inconsistencies and confusion in the manner environmental quality parameters were used and reported. A standard air pollution index, comparative guide to water quality indicators and biological monitoring information are being developed. (BT)

  9. MISR Current Project Quality

    Atmospheric Science Data Center

    2016-11-25

    ... may contain parameters at varying quality levels.   ORGANIZATION MISR Products are divided into four groups, Level 1, Level 2 ... are provided both to complement Standard Product quality information and to satisfy those who order the ancillary products. ARP ...

  10. Amelioration of lesions associated with 24-hour suboptimal platelet storage at 16 °C by a p38MAPK inhibitor, VX-702.

    PubMed

    Wagner, S J; Skripchenko, A; Seetharaman, S; Kurtz, J

    2015-04-01

    Previous studies with p38MAPK inhibitors at room temperature demonstrated that they improve a large number of platelet storage parameters, but cannot substantially inhibit p38MAPK activation nor protect against widespread decrements in platelet quality parameters during 4 °C storage. In this study, platelet quality parameters and inhibition of p38MAPK by VX-702 were studied after incubation of platelets at 16 °C without agitation, suboptimal storage conditions which produce moderate platelet decrements. Trima apheresis units were collected and aliquoted into three 60-ml CLX storage bags: (i) a control aliquot which was held at 20-24 °C with constant agitation; (ii) a test aliquot which was held at 20-24 °C with agitation until Day 2, when it was reincubated at 16 ± 1 °C for 24 ± 0·5 h without agitation and then returned 20-24 °C with agitation; (iii) a test aliquot containing 1 μm VX-702 stored in an identical fashion as aliquot 2. Aliquots were tested for an array of platelet storage parameters and p38MAPK activation on Days 1, 4 and 7. Many platelet storage parameters and p38MAPK activation were adversely affected by 24-h incubation at 16 °C without agitation. With the exception of ESC, addition of VX-702 prevented p38MAPK activation and the decrements in most observed parameters. Unlike 4 °C storage, VX-702 prevents activation of p38MAPK and decrements in many platelet storage parameters after exposure to 16 °C without agitation for 24 h. © 2014 International Society of Blood Transfusion.

  11. A Systematic Approach of Employing Quality by Design Principles: Risk Assessment and Design of Experiments to Demonstrate Process Understanding and Identify the Critical Process Parameters for Coating of the Ethylcellulose Pseudolatex Dispersion Using Non-Conventional Fluid Bed Process.

    PubMed

    Kothari, Bhaveshkumar H; Fahmy, Raafat; Claycamp, H Gregg; Moore, Christine M V; Chatterjee, Sharmista; Hoag, Stephen W

    2017-05-01

    The goal of this study was to utilize risk assessment techniques and statistical design of experiments (DoE) to gain process understanding and to identify critical process parameters for the manufacture of controlled release multiparticulate beads using a novel disk-jet fluid bed technology. The material attributes and process parameters were systematically assessed using the Ishikawa fish bone diagram and failure mode and effect analysis (FMEA) risk assessment methods. The high risk attributes identified by the FMEA analysis were further explored using resolution V fractional factorial design. To gain an understanding of the processing parameters, a resolution V fractional factorial study was conducted. Using knowledge gained from the resolution V study, a resolution IV fractional factorial study was conducted; the purpose of this IV study was to identify the critical process parameters (CPP) that impact the critical quality attributes and understand the influence of these parameters on film formation. For both studies, the microclimate, atomization pressure, inlet air volume, product temperature (during spraying and curing), curing time, and percent solids in the coating solutions were studied. The responses evaluated were percent agglomeration, percent fines, percent yield, bead aspect ratio, median particle size diameter (d50), assay, and drug release rate. Pyrobuttons® were used to record real-time temperature and humidity changes in the fluid bed. The risk assessment methods and process analytical tools helped to understand the novel disk-jet technology and to systematically develop models of the coating process parameters like process efficiency and the extent of curing during the coating process.

  12. Linking disease symptoms and subtypes with personalized systems-based phenotypes: A proof of concept study

    PubMed Central

    Aschbacher, Kirstin; Adam, Emma K.; Crofford, Leslie J.; Kemeny, Margaret E.; Demitrack, Mark A.; Ben-Zvi, Amos

    2012-01-01

    A dynamic systems model was used to generate parameters describing a phenotype of Hypothalamic–Pituitary–Adrenal (HPA) behavior in a sample of 36 patients with chronic fatigue syndrome (CFS) and/ or fibromyalgia (FM) and 36 case-matched healthy controls. Altered neuroendocrine function, particularly in relation to somatic symptoms and poor sleep quality, may contribute to the pathophysiology of these disorders. Blood plasma was assayed for cortisol and ACTH every 10 min for 24 h. The dynamic model was specified with an ordinary differential equation using three parameters: (1) ACTH-adrenal signaling, (2) inhibitory feedback, and (3) non-ACTH influences. The model was ‘‘personalized’’ by estimating an individualized set of parameters from each participant’s data. Day and nighttime parameters were assessed separately. Two nocturnal parameters (ACTH-adrenal signaling and inhibitory feedback) significantly differentiated the two patient subgroups (“fatigue-predominant” patients with CFS only versus ‘‘pain-predominant’’ patients with FM and comorbid chronic fatigue) from controls (allp’s < .05), whereas daytime parameters and diurnal/nocturnal slopes did not. The same nocturnal parameters were significantly associated with somatic symptoms among patients (p’s < .05). There was a significantly different pattern of association between nocturnal non-ACTH influences and sleep quality among patients versus controls (p < .05). Although speculative, the finding that patient somatic symptoms decreased when more cortisol was produced per unit ACTH, is consistent with cortisol’s anti-inflammatory and sleep-modulatory effects. Patients’ HPA systems may compensate by promoting more rapid or sustained cortisol production. Mapping “behavioral phenotypes” of stress–arousal systems onto symptom clusters may help disentangle the pathophysiology of complex disorders with frequent comorbidity. PMID:22687333

  13. Finding an optimal strategy for measuring the quality of groundwater as a source for drinking water

    NASA Astrophysics Data System (ADS)

    van Driezum, Inge; Saracevic, Ernis; Scheibz, Jürgen; Zessner, Matthias; Kirschner, Alexander; Sommer, Regina; Farnleitner, Andreas; Blaschke, Alfred Paul

    2015-04-01

    A good chemical and microbiological water quality is of great importance in riverbank filtration systems that are used as public water supplies. Water quality is ideally monitored frequently at the drinking water well using a steady pumping rate. Monitoring source water (like groundwater) however, can be more challenging. First of all, piezometers should be drilled in the correct layer of the aquifer. Secondly, the sampling design should include all preferred parameters (microbiological and chemical parameters) and should also take the hydrological conditions into account. In this study, we made use of different geophysical techniques (ERT and FDEM) to select the optimal placement of the piezometers. We also designed a sampling strategy which can be used to sample fecal indicators, biostability parameters, standard chemical parameters and a wide range of micropollutants. Several time series experiments were carried out in the study site Porous GroundWater Aquifer (PGWA) - an urban floodplain extending on the left bank of the river Danube downstream of the City of Vienna, Austria. The upper layer of the PGWA consist of silt and has a thickness from 1 to 6 meter. The underlying confined aquifer consists of sand and gravel and has a thickness of in between 3 and 15 meter. Hydraulic conductivities range from 5 x 10-2 m/s up to 5 x 10-5 m/s. Underneath the aquifer are alternating sand and clay/silt layers. As fecal markers Escherichia coli, enterococci and aerobic spores were measured. Biostability was measured using leucine incorporation. Additionally, several micropollutants and standard chemical parameters were measured. Results showed that physical and chemical parameters stayed stable in all monitoring wells during extended purging. A similar trend could be observed for E coli and enterococci. In the wells close to the river, aerobic spores and leucine incorporation decreased after 30 min. of pumping, whereas the well close to the backwater showed a different pattern. Overall, purging for 45 minutes was the optimal sampling procedure for the microbiological parameters. Samples for the detection of micropollutants were taken after 15 min. purging.

  14. Effects of dietary Aspergillus meal prebiotic on turkey poults production parameters and bone qualities

    USDA-ARS?s Scientific Manuscript database

    The objective of this study was to evaluate the effects of dietary Aspergillus meal (AM), a prebiotic on performance and bone parameters of neonatal turkey poults. Prebiotics are nondigestible food ingredients that beneficially affect the host and have been shown to stimulate calcium and magnesium a...

  15. Comparative Analyses of MIRT Models and Software (BMIRT and flexMIRT)

    ERIC Educational Resources Information Center

    Yavuz, Guler; Hambleton, Ronald K.

    2017-01-01

    Application of MIRT modeling procedures is dependent on the quality of parameter estimates provided by the estimation software and techniques used. This study investigated model parameter recovery of two popular MIRT packages, BMIRT and flexMIRT, under some common measurement conditions. These packages were specifically selected to investigate the…

  16. A comparative study on cotton fiber length parameters’ effects on modeling yarn property

    USDA-ARS?s Scientific Manuscript database

    Fiber length is one of the key properties of cotton and has important influences on yarn production and yarn quality. Various parameters have been developed to characterize cotton fiber length in the past decades. This study was carried out to investigate the effects of these parameters and their ...

  17. Laser welding of polymers: phenomenological model for a quick and reliable process quality estimation considering beam shape influences

    NASA Astrophysics Data System (ADS)

    Timpe, Nathalie F.; Stuch, Julia; Scholl, Marcus; Russek, Ulrich A.

    2016-03-01

    This contribution presents a phenomenological, analytical model for laser welding of polymers which is suited for a quick process quality estimation for the practitioner. Besides material properties of the polymer and processing parameters like welding pressure, feed rate and laser power the model is based on a simple few parameter description of the size and shape of the laser power density distribution (PDD) in the processing zone. The model allows an estimation of the weld seam tensile strength. It is based on energy balance considerations within a thin sheet with the thickness of the optical penetration depth on the surface of the absorbing welding partner. The joining process itself is modelled by a phenomenological approach. The model reproduces the experimentally known process windows for the main process parameters correctly. Using the parameters describing the shape of the laser PDD the critical dependence of the process windows on the PDD shape will be predicted and compared with experiments. The adaption of the model to other laser manufacturing processes where the PDD influence can be modelled comparably will be discussed.

  18. Period Estimation for Sparsely-sampled Quasi-periodic Light Curves Applied to Miras

    NASA Astrophysics Data System (ADS)

    He, Shiyuan; Yuan, Wenlong; Huang, Jianhua Z.; Long, James; Macri, Lucas M.

    2016-12-01

    We develop a nonlinear semi-parametric Gaussian process model to estimate periods of Miras with sparsely sampled light curves. The model uses a sinusoidal basis for the periodic variation and a Gaussian process for the stochastic changes. We use maximum likelihood to estimate the period and the parameters of the Gaussian process, while integrating out the effects of other nuisance parameters in the model with respect to a suitable prior distribution obtained from earlier studies. Since the likelihood is highly multimodal for period, we implement a hybrid method that applies the quasi-Newton algorithm for Gaussian process parameters and search the period/frequency parameter space over a dense grid. A large-scale, high-fidelity simulation is conducted to mimic the sampling quality of Mira light curves obtained by the M33 Synoptic Stellar Survey. The simulated data set is publicly available and can serve as a testbed for future evaluation of different period estimation methods. The semi-parametric model outperforms an existing algorithm on this simulated test data set as measured by period recovery rate and quality of the resulting period-luminosity relations.

  19. A Model of Regularization Parameter Determination in Low-Dose X-Ray CT Reconstruction Based on Dictionary Learning

    PubMed Central

    Zhang, Cheng; Zhang, Tao; Li, Ming; Lu, Yanfei; You, Jiali; Guan, Yihui

    2015-01-01

    In recent years, X-ray computed tomography (CT) is becoming widely used to reveal patient's anatomical information. However, the side effect of radiation, relating to genetic or cancerous diseases, has caused great public concern. The problem is how to minimize radiation dose significantly while maintaining image quality. As a practical application of compressed sensing theory, one category of methods takes total variation (TV) minimization as the sparse constraint, which makes it possible and effective to get a reconstruction image of high quality in the undersampling situation. On the other hand, a preliminary attempt of low-dose CT reconstruction based on dictionary learning seems to be another effective choice. But some critical parameters, such as the regularization parameter, cannot be determined by detecting datasets. In this paper, we propose a reweighted objective function that contributes to a numerical calculation model of the regularization parameter. A number of experiments demonstrate that this strategy performs well with better reconstruction images and saving of a large amount of time. PMID:26550024

  20. Parameters of Solidifying Mixtures Transporting at Underground Ore Mining

    NASA Astrophysics Data System (ADS)

    Golik, Vladimir; Dmitrak, Yury

    2017-11-01

    The article is devoted to the problem of providing mining enterprises with solidifying filling mixtures at underground mining. The results of analytical studies using the data of foreign and domestic practice of solidifying mixtures delivery to stopes are given. On the basis of experimental practice the parameters of transportation of solidifying filling mixtures are given with an increase in their quality due to the effect of vibration in the pipeline. The mechanism of the delivery process and the procedure for determining the parameters of the forced oscillations of the pipeline, the characteristics of the transporting processes, the rigidity of the elastic elements of pipeline section supports and the magnitude of vibrator' driving force are detailed. It is determined that the quality of solidifying filling mixtures can be increased due to the rational use of technical resources during the transportation of mixtures, and as a result the mixtures are characterized by a more even distribution of the aggregate. The algorithm for calculating the parameters of the pipe vibro-transport of solidifying filling mixtures can be in demand in the design of mineral deposits underground mining technology.

Top