Sookpeng, Supawitoo; Butdee, Chitsanupong
2017-06-01
The study aimed to evaluate the image quality in terms of signal-to-noise ratio (SNR) and dose to the lens of the eye and the other nearby organs from the CT brain scan using an automatic tube current modulation (ATCM) system with or without CT gantry tilt is needed. An anthropomorphic phantom was scanned with different settings including use of different ATCM, fixed tube current time product (mAs) settings and degree angles of gantry tilt. Gafchromic film XR-QA2 was used to measure absorbed dose of the organs. Relative doses and SNR for the various scan settings were compared with the reference setting of the fixed 330 mAs. Average absorbed dose for the lens of the eyes varied from 8.7 to 21.7 mGy. The use of the ATCM system with the gantry tilt resulted in up to 60% decrease in the dose to the lens of the eye. SNR significantly decreased while tilting the gantry using the fixed mAs techniques, compared to that of the reference setting. However, there were no statistical significant differences for SNRs between the reference setting and all ATCM settings. Compared to the reference setting of the fixed effective mAs, using the ATCM system and appropriate tilting, the gantry resulted in a substantial decrease in the dose to the lens of the eye while preserving signal-to-noise ratio. CT brain examination should be carefully controlled to optimize dose for lens of the eye and image quality of the examination.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strauss, K; Nachabe, R; Racadio, J
Purpose: To define an alternative to antiscatter grid (ASG) removal in angiographic systems which achieves similar patient dose reduction as ASG removal without degrading image quality during pediatric imaging. Methods: This study was approved by the local institution animal care and use committee (IACUC). Six different digital subtraction angiography settings were evaluated that altered the mAs, (100, 70, 50, 35, 25, 17.5% of reference mAs) with and without ASG. Three pigs of 5, 15, and 20 kg (9, 15, and 17 cm abdominal thickness; smaller than a newborn, average 3 yr old, and average 10 year old human abdomen respectively)more » were imaged using the six dose settings with and without ASG. Image quality was defined as the order of vessel branch that is visible relative to the injected vessel. Five interventional radiologists evaluated all images. Image quality and patient dose were statistically compared using analysis of variance and receiver operating curve (ROC) analysis to define the preferred dose level and use of ASG for a minimum visibility of 2nd or 3rd order branches of vessel visibility. Results: ASG grid removal reduces dose by 26% with reduced image quality. Only with the ASG present can 3rd order branches be visualized; 100% mAs is required for 9 cm pig while 70% mAs is adequate for the larger pigs. 2nd order branches can be visualized with ASG at 17.5% mAs for all three pig sizes. Without the ASG, 50%, 35% and 35% mAs is required for smallest to largest pig. Conclusion: Removing ASG reduces patient dose and image quality. Image quality can be improved with the ASG present while further reducing patient dose if an optimized radiographic technique is used. Rami Nachabe is an employee of Philips Health Care; Keith Strauss is a paid consultant of Philips Health Care.« less
Radiation dose reduction in chest radiography using a flat-panel amorphous silicon detector.
Hosch, W P; Fink, C; Radeleff, B; kampschulte a, A; Kauffmann, G W; Hansmann, J
2002-10-01
The aim of this study was to evaluate the image quality and the potential for radiation dose reduction with a digital flat-panel amorphous silicon detector radiography system. Using flat-panel technology, radiographs of an anthropomorphic thorax phantom were taken with a range of technical parameters (125kV, 200mA and 5, 4, 3.2, 2, 1, 0.5, and 0.25mAs) which were equivalent to a radiation dose of 332, 263, 209, 127, 58.7, 29, and 14 microGy, respectively. These images were compared to radiographs obtained by a conventional film-screen radiography system at 125kV, 200mA and 5mAs (equivalent to 252 microGy) which served as reference. Three observers evaluated independently the visibility of simulated rounded lesions and anatomical structures, comparing printed films from the flat-panel amorphous silicon detector and conventional x-ray system films. With flat-panel technology, the visibility of rounded lesions and normal anatomical structures at 5, 4, and 3.2mAs was superior compared to the conventional film-screen radiography system. (P< or =0.0001). At 2mAs, improvement was only marginal (P=0.19). At 1.0, 0.5 and 0.25mAs, the visibility of simulated rounded lesions was worse (P< or =0.004). Comparing fine lung parenchymal structures, the flat-panel amorphous silicon detector showed improvement for all exposure levels down to 2mAs and equality at 1mAs. Compared to a conventional x-ray film system, the flat-panel amorphous silicon detector demonstrated improved image quality and the possibility for a reduction of the radiation dose by 50% without loss in image quality.
Fourney, Daryl R; Dettori, Joseph R; Norvell, Daniel C; Dekutoski, Mark B
2010-04-20
Systematic review. The purpose of this review was to attempt to answer the following 2 clinical questions: (1) Does minimal access tubular assisted spine surgery (MAS) decrease the rate of complications in posterior thoracolumbar decompression and/or fusion surgery compared with traditional open techniques? (2) What strategies to reduce the risk of complications in MAS have been shown to be effective? The objective of minimal access spine surgery is to reduce damage to surrounding tissues while accomplishing the same goals as conventional surgery. Patient demand and marketing for MAS is driven by the perception of better outcomes, although the purported advantages remain unproven. Whether the risk of complications is affected by minimal access techniques is unknown. A systematic review of the English language literature was undertaken for articles published between 1990 and July 2009. Electronic databases and reference lists of key articles were searched to identify published studies that compared the rate of complications after MAS to a control group that underwent open surgery. Single-arm studies were excluded. Two independent reviewers assessed the strength of literature using GRADE criteria assessing quality, quantity, and consistency of results. Disagreements were resolved by consensus. From the 361 articles identified, 13 met a priori criteria and were included for review. All of the studies evaluated only lumbar spine surgery. The single large randomized study showed less favorable results for MAS discectomy, but no significant difference in complication rates. The quality of the other studies, particularly for fusion surgery, was low. Overall, the rates of reoperation, dural tear, cerebrospinal fluid leak, nerve injury, and infection occurred in similar proportions between MAS and open surgery. Blood loss was reduced in MAS fusion; however, the quality of those studies was very low. Operation time and hospital length of stay was variable across studies. There was no evidence to assess the effectiveness of strategies to reduce the risk of complications in MAS. Some data suggests that the rate of complications may decrease with experience. (1) Compared to open techniques, MAS does not decrease the rate of complications for posterior lumbar spinal decompression or fusion. (2) There is no evidence to assess the effectiveness of strategies to reduce the risk of MAS-related complications.
Ho, Robin S T; Wu, Xinyin; Yuan, Jinqiu; Liu, Siya; Lai, Xin; Wong, Samuel Y S; Chung, Vincent C H
2015-01-08
Meta-analysis (MA) of randomised trials is considered to be one of the best approaches for summarising high-quality evidence on the efficacy and safety of treatments. However, methodological flaws in MAs can reduce the validity of conclusions, subsequently impairing the quality of decision making. To assess the methodological quality of MAs on COPD treatments. A cross-sectional study on MAs of COPD trials. MAs published during 2000-2013 were sampled from the Cochrane Database of Systematic Reviews and Database of Abstracts of Reviews of Effect. Methodological quality was assessed using the validated AMSTAR (Assessing the Methodological Quality of Systematic Reviews) tool. Seventy-nine MAs were sampled. Only 18% considered the scientific quality of primary studies when formulating conclusions and 49% used appropriate meta-analytic methods to combine findings. The problems were particularly acute among MAs on pharmacological treatments. In 48% of MAs the authors did not report conflict of interest. Fifty-eight percent reported harmful effects of treatment. Publication bias was not assessed in 65% of MAs, and only 10% had searched non-English databases. The methodological quality of the included MAs was disappointing. Consideration of scientific quality when formulating conclusions should be made explicit. Future MAs should improve on reporting conflict of interest and harm, assessment of publication bias, prevention of language bias and use of appropriate meta-analytic methods.
Ho, Robin ST; Wu, Xinyin; Yuan, Jinqiu; Liu, Siya; Lai, Xin; Wong, Samuel YS; Chung, Vincent CH
2015-01-01
Background: Meta-analysis (MA) of randomised trials is considered to be one of the best approaches for summarising high-quality evidence on the efficacy and safety of treatments. However, methodological flaws in MAs can reduce the validity of conclusions, subsequently impairing the quality of decision making. Aims: To assess the methodological quality of MAs on COPD treatments. Methods: A cross-sectional study on MAs of COPD trials. MAs published during 2000–2013 were sampled from the Cochrane Database of Systematic Reviews and Database of Abstracts of Reviews of Effect. Methodological quality was assessed using the validated AMSTAR (Assessing the Methodological Quality of Systematic Reviews) tool. Results: Seventy-nine MAs were sampled. Only 18% considered the scientific quality of primary studies when formulating conclusions and 49% used appropriate meta-analytic methods to combine findings. The problems were particularly acute among MAs on pharmacological treatments. In 48% of MAs the authors did not report conflict of interest. Fifty-eight percent reported harmful effects of treatment. Publication bias was not assessed in 65% of MAs, and only 10% had searched non-English databases. Conclusions: The methodological quality of the included MAs was disappointing. Consideration of scientific quality when formulating conclusions should be made explicit. Future MAs should improve on reporting conflict of interest and harm, assessment of publication bias, prevention of language bias and use of appropriate meta-analytic methods. PMID:25569783
Gomes, Manuel; Pennington, Mark; Wittenberg, Raphael; Knapp, Martin; Black, Nick; Smith, Sarah
2017-01-01
Background Policy makers in England advocate referral of patients with suspected dementia to Memory Assessment Services (MAS), but it is unclear how any improvement in patients' health-related quality of life (HRQL) compares with the associated costs. Aims To evaluate the cost-effectiveness of MAS for the diagnosis and follow-up care of patients with suspected dementia. Method We analysed observational data from 1318 patients referred to 69 MAS, and their lay carers (n = 944), who completed resource use and HRQL questionnaires at baseline, three and six months. We reported mean differences in HRQL (disease-specific DEMQOL and generic EQ-5D-3L), quality-adjusted life years (QALYs) and costs between baseline and six months after referral to MAS. We also assessed the cost-effectiveness of MAS across different patient subgroups and clinic characteristics. Results Referral to MAS was associated with gains in DEMQOL (mean gain: 3.48, 95% confidence interval: 2.84 to 4.12), EQ-5D-3L (0.023, 0.008 to 0.038) and QALYs (0.006, 0.002 to 0.01). Mean total cost over six months, assuming a societal perspective, was £1899 (£1277 to £2539). This yielded a negative incremental net monetary benefit of -£1724 (-£2388 to -£1085), assuming NICE's recommended willingness-to-pay threshold (£30,000 per QALY). These base case results were relatively robust to alternative assumptions about costs and HRQL. There was some evidence that patients aged 80 or older benefitted more from referral to MAS (p < 0.01 from adjusted mean differences in net benefits) compared to younger patients. MAS with over 75 new patients a month or cost per patient less than £2500 over six months were relatively more cost-effective (p < 0.01) than MAS with fewer new monthly patients or higher cost per patient. Conclusions Diagnosis, treatment and follow-up care provided by MAS to patients with suspected dementia appears to be effective, but not cost-effective, in the six months after diagnosis. Longer term evidence is required before drawing conclusions about the cost-effectiveness of MAS.
Gaia Data Release 1. Astrometry: one billion positions, two million proper motions and parallaxes
NASA Astrophysics Data System (ADS)
Lindegren, L.; Lammers, U.; Bastian, U.; Hernández, J.; Klioner, S.; Hobbs, D.; Bombrun, A.; Michalik, D.; Ramos-Lerate, M.; Butkevich, A.; Comoretto, G.; Joliet, E.; Holl, B.; Hutton, A.; Parsons, P.; Steidelmüller, H.; Abbas, U.; Altmann, M.; Andrei, A.; Anton, S.; Bach, N.; Barache, C.; Becciani, U.; Berthier, J.; Bianchi, L.; Biermann, M.; Bouquillon, S.; Bourda, G.; Brüsemeister, T.; Bucciarelli, B.; Busonero, D.; Carlucci, T.; Castañeda, J.; Charlot, P.; Clotet, M.; Crosta, M.; Davidson, M.; de Felice, F.; Drimmel, R.; Fabricius, C.; Fienga, A.; Figueras, F.; Fraile, E.; Gai, M.; Garralda, N.; Geyer, R.; González-Vidal, J. J.; Guerra, R.; Hambly, N. C.; Hauser, M.; Jordan, S.; Lattanzi, M. G.; Lenhardt, H.; Liao, S.; Löffler, W.; McMillan, P. J.; Mignard, F.; Mora, A.; Morbidelli, R.; Portell, J.; Riva, A.; Sarasso, M.; Serraller, I.; Siddiqui, H.; Smart, R.; Spagna, A.; Stampa, U.; Steele, I.; Taris, F.; Torra, J.; van Reeven, W.; Vecchiato, A.; Zschocke, S.; de Bruijne, J.; Gracia, G.; Raison, F.; Lister, T.; Marchant, J.; Messineo, R.; Soffel, M.; Osorio, J.; de Torres, A.; O'Mullane, W.
2016-11-01
Context. Gaia Data Release 1 (DR1) contains astrometric results for more than 1 billion stars brighter than magnitude 20.7 based on observations collected by the Gaia satellite during the first 14 months of its operational phase. Aims: We give a brief overview of the astrometric content of the data release and of the model assumptions, data processing, and validation of the results. Methods: For stars in common with the Hipparcos and Tycho-2 catalogues, complete astrometric single-star solutions are obtained by incorporating positional information from the earlier catalogues. For other stars only their positions are obtained, essentially by neglecting their proper motions and parallaxes. The results are validated by an analysis of the residuals, through special validation runs, and by comparison with external data. Results: For about two million of the brighter stars (down to magnitude 11.5) we obtain positions, parallaxes, and proper motions to Hipparcos-type precision or better. For these stars, systematic errors depending for example on position and colour are at a level of ± 0.3 milliarcsecond (mas). For the remaining stars we obtain positions at epoch J2015.0 accurate to 10 mas. Positions and proper motions are given in a reference frame that is aligned with the International Celestial Reference Frame (ICRF) to better than 0.1 mas at epoch J2015.0, and non-rotating with respect to ICRF to within 0.03 mas yr-1. The Hipparcos reference frame is found to rotate with respect to the Gaia DR1 frame at a rate of 0.24 mas yr-1. Conclusions: Based on less than a quarter of the nominal mission length and on very provisional and incomplete calibrations, the quality and completeness of the astrometric data in Gaia DR1 are far from what is expected for the final mission products. The present results nevertheless represent a huge improvement in the available fundamental stellar data and practical definition of the optical reference frame.
Lell, M M; May, M S; Brand, M; Eller, A; Buder, T; Hofmann, E; Uder, M; Wuest, W
2015-07-01
CT is the imaging technique of choice in the evaluation of midface trauma or inflammatory disease. We performed a systematic evaluation of scan protocols to optimize image quality and radiation exposure on third-generation dual-source CT. CT protocols with different tube voltage (70-150 kV), current (25-300 reference mAs), prefiltration, pitch value, and rotation time were systematically evaluated. All images were reconstructed with iterative reconstruction (Advanced Modeled Iterative Reconstruction, level 2). To individually compare results with otherwise identical factors, we obtained all scans on a frozen human head. Conebeam CT was performed for image quality and dose comparison with multidetector row CT. Delineation of important anatomic structures and incidental pathologic conditions in the cadaver head was evaluated. One hundred kilovolts with tin prefiltration demonstrated the best compromise between dose and image quality. The most dose-effective combination for trauma imaging was Sn100 kV/250 mAs (volume CT dose index, 2.02 mGy), and for preoperative sinus surgery planning, Sn100 kV/150 mAs (volume CT dose index, 1.22 mGy). "Sn" indicates an additional prefiltration of the x-ray beam with a tin filter to constrict the energy spectrum. Exclusion of sinonasal disease was possible with even a lower dose by using Sn100 kV/25 mAs (volume CT dose index, 0.2 mGy). High image quality at very low dose levels can be achieved by using a Sn100-kV protocol with iterative reconstruction. The effective dose is comparable with that of conventional radiography, and the high image quality at even lower radiation exposure favors multidetector row CT over conebeam CT. © 2015 by American Journal of Neuroradiology.
NASA Astrophysics Data System (ADS)
Orlicki, Katharine M.
There is a great need in many cities for a better quality of urban soil maps. This is due to the increasing interest in repurposing vacant land for urban redevelopment, agriculture, and green infrastructure. Mapping vacant urban land in Detroit can be very difficult because anthropogenic soils were often highly variable and frequently contained demolition debris (such as brick), making it difficult to use a hand auger. This study was undertaken in Detroit, MI to create a more efficient way to map urban soils based on their geophysical and chemical properties. This will make the mapping process faster, less labor intensive, and therefore more cost effective. Optical and chemical criteria for the identification and classification of microartifacts (MAs) were made from a set of reference artifacts of a known origin. These MAs were then observed and tested in urban topsoil samples from sites in Detroit, Michigan that represent three different land use types (residential demolition, fly ash-impacted, and industrial). Optical analyses, SEM, EDAX, and XRD showed that reference MAs may be classified into five basic compositional types (carbonaceous, calcareous, siliceous, ferruginous and miscellaneous). Reference MAs were generally distinguishable using optical microscopy by color, luster, fracture and microtexture. MAs that were more difficult to classify were further differentiable when using SEM, EDAX, and XRD. MAs were found in all of the anthropogenic soils studied, but were highly variable. All three study sites had concentrations coal-related wastes were the most common types of MAs observed and often included coal, ash (microspheres, microagglomerate), cinders, and burnt shale. MAs derived from waste building materials such as brick, mortar, and glass, were typically found on residential demolition sites. Manufacturing waste MAs, which included iron-making slag and coked coal were commonly observed on industrial sites. Fly ash-impacted sites were composed of only microspheres and microagglomerate that were concentrated within the soils by airborne deposition, making it widespread. These results support the hypothesis that MA assemblages of distinct composition vary with land use. Therefore, it seems likely that magnetic susceptibility surveying and other geophysical methods will prove effective for mapping anthropogenic soils on vacant urban land. Anthropogenic soils and MAs were assessed for pH, electrical conductivity (EC), and magnetic susceptibility (MS). The A horizons of urban soils at residential demolition, industrial-impacted, and fly ash-impacted sites were found to be distinguishable from those of native soils. Anthropogenic soils were higher by one pH unit or more than the background level, had an EC value two to three times the background level, and had MS measurements up to 20 times greater than the background level. The analysis of reference artifacts suggested that the elevated pH of anthropogenic soils was caused by calcareous building material wastes, the elevated EC were the result of both calcareous and ferruginous wastes, and elevated MS were attributable to ferromagnetic materials. Anthropogenic soils collected at residential demolition sites were differentiable by EC, whereas those at collected form industrial sites were distinguishable using MS. Therefore, anthropogenic soils and native soils have a unique chemical and geophysical signature which can be highly dependent on the concentration of MAs. This suggests that EC and MS surveying methods may be used to remotely sense and map urban soils more effectively than using traditional methods alone.
Allmendinger, Thomas; Kunz, Andreas S; Veyhl-Wichmann, Maike; Ergün, Süleyman; Bley, Thorsten A; Petritsch, Bernhard
2017-01-01
Background Coronary artery calcium (CAC) scoring is a widespread tool for cardiac risk assessment in asymptomatic patients and accompanying possible adverse effects, i.e. radiation exposure, should be as low as reasonably achievable. Purpose To evaluate a new iterative reconstruction (IR) algorithm for dose reduction of in vitro coronary artery calcium scoring at different tube currents. Material and Methods An anthropomorphic calcium scoring phantom was scanned in different configurations simulating slim, average-sized, and large patients. A standard calcium scoring protocol was performed on a third-generation dual-source CT at 120 kVp tube voltage. Reference tube current was 80 mAs as standard and stepwise reduced to 60, 40, 20, and 10 mAs. Images were reconstructed with weighted filtered back projection (wFBP) and a new version of an established IR kernel at different strength levels. Calcifications were quantified calculating Agatston and volume scores. Subjective image quality was visualized with scans of an ex vivo human heart. Results In general, Agatston and volume scores remained relatively stable between 80 and 40 mAs and increased at lower tube currents, particularly in the medium and large phantom. IR reduced this effect, as both Agatston and volume scores decreased with increasing levels of IR compared to wFBP (P < 0.001). Depending on selected parameters, radiation dose could be lowered by up to 86% in the large size phantom when selecting a reference tube current of 10 mAs with resulting Agatston levels close to the reference settings. Conclusion New iterative reconstruction kernels may allow for reduction in tube current for established Agatston scoring protocols and consequently for substantial reduction in radiation exposure. PMID:28607763
Zhang, Zhe-wen; Cheng, Juan; Liu, Zhuan; Ma, Ji-chun; Li, Jin-long; Wang, Jing; Yang, Ke-hu
2015-12-07
The aim of this study was to examine the epidemiological and reporting characteristics as well as the methodological quality of meta-analyses (MAs) of observational studies published in Chinese journals. 5 Chinese databases were searched for MAs of observational studies published from January 1978 to May 2014. Data were extracted into Excel spreadsheets, and Meta-analysis of Observational Studies in Epidemiology (MOOSE) and Assessment of Multiple Systematic Reviews (AMSTAR) checklists were used to assess reporting characteristics and methodological quality, respectively. A total of 607 MAs were included. Only 52.2% of the MAs assessed the quality of the included primary studies, and the retrieval information was not comprehensive in more than half (85.8%) of the MAs. In addition, 50 (8.2%) MAs did not search any Chinese databases, while 126 (20.8%) studies did not search any English databases. Approximately 41.2% of the MAs did not describe the statistical methods in sufficient details, and most (95.5%) MAs did not report on conflicts of interest. However, compared with the before publication of the MOOSE Checklist, the quality of reporting improved significantly for 20 subitems after publication of the MOOSE Checklist, and 7 items of the included MAs demonstrated significant improvement after publication of the AMSTAR Checklist (p<0.05). Although many MAs of observational studies have been published in Chinese journals, the reporting quality is questionable. Thus, there is an urgent need to increase the use of reporting guidelines and methodological tools in China; we recommend that Chinese journals adopt the MOOSE and AMSTAR criteria. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Wu, Xin Yin; Lam, Victor C K; Yu, Yue Feng; Ho, Robin S T; Feng, Ye; Wong, Charlene H L; Yip, Benjamin H K; Tsoi, Kelvin K F; Wong, Samuel Y S; Chung, Vincent C H
2016-11-01
Well-conducted meta-analyses (MAs) are considered as one of the best sources of clinical evidence for treatment decision. MA with methodological flaws may introduce bias and mislead evidence users. The aim of this study is to investigate the characteristics and methodological quality of MAs on diabetes mellitus (DM) treatments. Systematic review. Cochrane Database of Systematic Review and Database of Abstract of Reviews of Effects were searched for relevant MAs. Assessing methodological quality of systematic reviews (AMSTAR) tool was used to evaluate the methodological quality of included MAs. Logistic regression analysis was used to identify association between characteristics of MA and AMSTAR results. A total of 252 MAs including 4999 primary studies and 13,577,025 patients were included. Over half of the MAs (65.1%) only included type 2 DM patients and 160 MAs (63.5%) focused on pharmacological treatments. About 89.7% MAs performed comprehensive literature search and 89.3% provided characteristics of included studies. Included MAs generally had poor performance on the remaining AMSTAR items, especially in assessing publication bias (39.3%), providing lists of studies (19.0%) and declaring source of support comprehensively (7.5%). Only 62.7% MAs mentioned about harm of interventions. MAs with corresponding author from Asia performed less well in providing MA protocol than those from Europe. Methodological quality of MA on DM treatments was unsatisfactory. There is considerable room for improvement, especially in assessing publication bias, providing lists of studies and declaring source of support comprehensively. Also, there is an urgent need for MA authors to report treatment harm comprehensively. © 2016 European Society of Endocrinology.
Papageorgiou, Spyridon N; Papadopoulos, Moschos A; Athanasiou, Athanasios E
2014-02-01
Ideally meta-analyses (MAs) should consolidate the characteristics of orthodontic research in order to produce an evidence-based answer. However severe flaws are frequently observed in most of them. The aim of this study was to evaluate the statistical methods, the methodology, and the quality characteristics of orthodontic MAs and to assess their reporting quality during the last years. Electronic databases were searched for MAs (with or without a proper systematic review) in the field of orthodontics, indexed up to 2011. The AMSTAR tool was used for quality assessment of the included articles. Data were analyzed with Student's t-test, one-way ANOVA, and generalized linear modelling. Risk ratios with 95% confidence intervals were calculated to represent changes during the years in reporting of key items associated with quality. A total of 80 MAs with 1086 primary studies were included in this evaluation. Using the AMSTAR tool, 25 (27.3%) of the MAs were found to be of low quality, 37 (46.3%) of medium quality, and 18 (22.5%) of high quality. Specific characteristics like explicit protocol definition, extensive searches, and quality assessment of included trials were associated with a higher AMSTAR score. Model selection and dealing with heterogeneity or publication bias were often problematic in the identified reviews. The number of published orthodontic MAs is constantly increasing, while their overall quality is considered to range from low to medium. Although the number of MAs of medium and high level seems lately to rise, several other aspects need improvement to increase their overall quality.
Integrated circuit detector technology in abdominal CT: added value in obese patients.
Morsbach, Fabian; Bickelhaupt, Sebastian; Rätzer, Susan; Schmidt, Bernhard; Alkadhi, Hatem
2014-02-01
The purpose of this article was to assess the effect of an integrated circuit (IC) detector for abdominal CT on image quality. In the first study part, an abdominal phantom was scanned with various extension rings using a CT scanner equipped with a conventional discrete circuit (DC) detector and on the same scanner with an IC detector (120 kVp, 150 effective mAs, and 75 effective mAs). In the second study part, 20 patients were included who underwent abdominal CT both with the IC detector and previously at similar protocol parameters (120 kVp tube current-time product and 150 reference mAs using automated tube current modulation) with the DC detector. Images were reconstructed with filtered back projection. Image quality in the phantom was higher for images acquired with the IC compared with the DC detector. There was a gradually increasing noise reduction with increasing phantom sizes, with the highest (37% in the largest phantom) at 75 effective mAs (p < 0.001). In patients, noise was overall significantly (p = 0.025) reduced by 6.4% using the IC detector. Similar to the phantom, there was a gradual increase in noise reduction to 7.9% in patients with a body mass index of 25 kg/m(2) or lower (p = 0.008). Significant correlation was found in patients between noise and abdominal diameter in DC detector images (r = 0.604, p = 0.005), whereas no such correlation was found for the IC detector (r = 0.427, p = 0.060). Use of an IC detector in abdominal CT improves image quality and reduces image noise, particularly in overweight and obese patients. This noise reduction has the potential for dose reduction in abdominal CT.
NASA Astrophysics Data System (ADS)
Rulaidi, W. E. P.; Huri, M. S. N.; Ng, K. H.
2017-05-01
One method to optimise the use of x-rays in CT and hence a reduction in patient dose is the application of automatic exposure control (AEC). This study measured the effective mAs, image noise and volume CT dose index (CTDIvol) as the result of changing the AEC index on a Siemens Somatom Definition 64 slices dual source CT scanner. The scans were performed on four phantoms of different geometries, namely the 16 and 32 cm cylindrical CTDI phantoms and two anthropomorphic phantoms, RANDO (20 cm effective diameter) and ATOM (19.8 cm effective diameter). Results showed that the effective mAs increased with increasing tube potential (kVp) and Quality Reference mAs (QRM), therefore increasing CTDIvol while reducing image noise. Meanwhile, no changes of radiation dose and image noise were observed when the pitch was increased. However, for the largest phantom (32 cm effective diameter), a constant effective mAs was found between 120 and 140 kVp. The same trend was also found with increasing QRM from 300 mAs to 400 mAs suggesting a certain limitation of the AEC has been reached. In conclusion, this study showed that AEC is affected by kVp and QRM but not by pitch selection. Further work is required to quantify the characteristics of the AEC system in relation to the mentioned parameters for better optimisation.
Dong, Jinpei; Teng, Guigen; Wei, Tiantong; Gao, Wen; Wang, Huahong
2016-01-01
Probiotics are widely used for the induction and maintenance of remission in inflammatory bowel disease (IBD) and pouchitis. There are a large number of meta-analyses (MAs)/ systematic reviews (SRs) on this subject, the methodological quality of which has not been evaluated. This study aimed to evaluate the methodological quality of and summarize the evidence obtained from MAs/SRs of probiotic treatments for IBD and pouchitis patients. The PubMed, EMBASE, Cochrane Library and China National Knowledge Infrastructure (CNKI) databases were searched to identify Chinese and English language MAs/SRs of the use of probiotics for IBD and pouchitis. The Assessment of Multiple Systematic Reviews (AMSTAR) scale was used to assess the methodological quality of the studies. A total of 36 MAs/SRs were evaluated. The AMSTAR scores of the included studies ranged from 1 to 10, and the average score was 5.81. According to the Canadian Agency for Drugs and Technologies in Health, 4 articles were classified as high quality, 24 articles were classified as moderate quality, and 8 articles were classified as low quality. Most of the MAs/SRs suggested that probiotics had potential benefits for patients with ulcerative colitis (UC), but failed to show effectiveness in the induction and maintenance of remission in Crohn's disease (CD). The probiotic preparation VSL#3 may play a beneficial role in pouchitis. The overall methodological quality of the current MAs/SRs in the field of probiotics for IBD and pouchitis was found to be low to moderate. More MAs/SRs of high quality are required to support using probiotics to treat IBD and pouchitis.
New Astronomical Reduction of Old Observations (the NAROO project)
NASA Astrophysics Data System (ADS)
Arlot, Jean-Eudes; Robert, Vincent; Lainey, Valery; Neiner, Coralie; Thouvenin, Nicolas
2018-04-01
The Gaia astrometric reference catalogue will provide star proper motions with an accuracy of one mas one century ago for stars of magnitude 14 or brighter. Our project is to re-reduced the old observations with the new catalogue allowing to have an astrometric accuracy only limited by the observational biases and not by reference stars. Then, we plan to get an accuracy of 50 mas where the old reductions were not better than 500 mas! For our purpose, we will digitize old photographic plates with a sub-micrometric scanner. Tests were made using the UCAC catalogue showing that old photographic plates have an intrinsect accuracy of 30 to 60 mas.
Thomas, Christoph; Heuschmid, Martin; Schilling, David; Ketelsen, Dominik; Tsiflikas, Ilias; Stenzl, Arnulf; Claussen, Claus D; Schlemmer, Heinz-Peter
2010-11-01
To retrospectively evaluate radiation dose, image quality, and the ability to differentiate urinary calculi of differing compositions by using low-dose dual-energy computed tomography (CT). The institutional review board approved this retrospective study; informed consent was waived. A low-dose dual-energy CT protocol (tube voltage and reference effective tube current-time product, 140 kV and 23 mAs and 80 kV and 105 mAs; collimation, 64 × 0.6 mm; pitch, 0.7) for the detection of urinary calculi was implemented into routine clinical care. All patients (n = 112) who were examined with this protocol from July 2008 to August 2009 were included. The composition of urinary calculi was assessed by using commercially available postprocessing software and was compared with results of the reference standard (ex vivo infrared spectroscopy) in 40 patients for whom the reference standard was available. Effective doses were calculated. Image quality was rated subjectively and objectively and was correlated with patient size expressed as body cross-sectional area at the level of acquisition by using Spearman correlation coefficients. One calcified concrement in the distal ureter of an obese patient was mistakenly interpreted as mixed calcified and uric acid. One struvite calculus was falsely interpreted as cystine. All other uric acid, cystine, and calcium-containing calculi were correctly identified by using dual-energy CT. The mean radiation dose was 2.7 mSv. The average image quality was rated as acceptable, with a decrease in image quality in larger patients. Low-dose unenhanced dual-source dual-energy CT can help differentiate between calcified, uric acid, and cystine calculi at a radiation dose comparable to that of conventional intravenous pyelography. Because of decreased image quality in obese patients, only nonobese patients should be examined with this protocol. © RSNA, 2010.
VIRAC: the VVV Infrared Astrometric Catalogue
NASA Astrophysics Data System (ADS)
Smith, L. C.; Lucas, P. W.; Kurtev, R.; Smart, R.; Minniti, D.; Borissova, J.; Jones, H. R. A.; Zhang, Z. H.; Marocco, F.; Contreras Peña, C.; Gromadzki, M.; Kuhn, M. A.; Drew, J. E.; Pinfield, D. J.; Bedin, L. R.
2018-02-01
We present VIRAC version 1, a near-infrared proper motion and parallax catalogue of the VISTA Variables in the Via Lactea (VVV) survey for 312 587 642 unique sources averaged across all overlapping pawprint and tile images covering 560 deg2 of the bulge of the Milky Way and southern disc. The catalogue includes 119 million high-quality proper motion measurements, of which 47 million have statistical uncertainties below 1 mas yr-1. In the 11 < Ks < 14 magnitude range, the high-quality motions have a median uncertainty of 0.67 mas yr-1. The catalogue also includes 6935 sources with quality-controlled 5σ parallaxes with a median uncertainty of 1.1 mas. The parallaxes show reasonable agreement with the Tycho-Gaia Astrometric Solution, though caution is advised for data with modest significance. The SQL data base housing the data is made available via the web. We give example applications for studies of Galactic structure, nearby objects (low-mass stars and brown dwarfs, subdwarfs, white dwarfs) and kinematic distance measurements of young stellar objects. Nearby objects discovered include LTT 7251 B, an L7 benchmark companion to a G dwarf with over 20 published elemental abundances, a bright L subdwarf, VVV 1256-6202, with extremely blue colours and nine new members of the 25 pc sample. We also demonstrate why this catalogue remains useful in the era of Gaia. Future versions will be based on profile fitting photometry, use the Gaia absolute reference frame and incorporate the longer time baseline of the VVV extended survey.
Optimization of dose and image quality in adult and pediatric computed tomography scans
NASA Astrophysics Data System (ADS)
Chang, Kwo-Ping; Hsu, Tzu-Kun; Lin, Wei-Ting; Hsu, Wen-Lin
2017-11-01
Exploration to maximize CT image and reduce radiation dose was conducted while controlling for multiple factors. The kVp, mAs, and iteration reconstruction (IR), affect the CT image quality and radiation dose absorbed. The optimal protocols (kVp, mAs, IR) are derived by figure of merit (FOM) based on CT image quality (CNR) and CT dose index (CTDIvol). CT image quality metrics such as CT number accuracy, SNR, low contrast materials' CNR and line pair resolution were also analyzed as auxiliary assessments. CT protocols were carried out with an ACR accreditation phantom and a five-year-old pediatric head phantom. The threshold values of the adult CT scan parameters, 100 kVp and 150 mAs, were determined from the CT number test and line pairs in ACR phantom module 1and module 4 respectively. The findings of this study suggest that the optimal scanning parameters for adults be set at 100 kVp and 150-250 mAs. However, for improved low- contrast resolution, 120 kVp and 150-250 mAs are optimal. Optimal settings for pediatric head CT scan were 80 kVp/50 mAs, for maxillary sinus and brain stem, while 80 kVp /300 mAs for temporal bone. SNR is not reliable as the independent image parameter nor the metric for determining optimal CT scan parameters. The iteration reconstruction (IR) approach is strongly recommended for both adult and pediatric CT scanning as it markedly improves image quality without affecting radiation dose.
Schreiner, Markus M; Platzgummer, Hannes; Unterhumer, Sylvia; Weber, Michael; Mistelbauer, Gabriel; Loewe, Christian; Schernthaner, Ruediger E
2017-08-01
To investigate radiation exposure, objective image quality, and the diagnostic accuracy of a BMI-adjusted ultra-low-dose CT angiography (CTA) protocol for the assessment of peripheral arterial disease (PAD), with digital subtraction angiography (DSA) as the standard of reference. In this prospective, IRB-approved study, 40 PAD patients (30 male, mean age 72 years) underwent CTA on a dual-source CT scanner at 80kV tube voltage. The reference amplitude for tube current modulation was personalized based on the body mass index (BMI) with 120 mAs for [BMI≤25] or 150 mAs for [25
An image quality comparison study between XVI and OBI CBCT systems.
Kamath, Srijit; Song, William; Chvetsov, Alexei; Ozawa, Shuichi; Lu, Haibin; Samant, Sanjiv; Liu, Chihray; Li, Jonathan G; Palta, Jatinder R
2011-02-04
The purpose of this study is to evaluate and compare image quality characteristics for two commonly used and commercially available CBCT systems: the X-ray Volumetric Imager and the On-Board Imager. A commonly used CATPHAN image quality phantom was used to measure various image quality parameters, namely, pixel value stability and accuracy, noise, contrast to noise ratio (CNR), high-contrast resolution, low contrast resolution and image uniformity. For the XVI unit, we evaluated the image quality for four manufacturer-supplied protocols as a function of mAs. For the OBI unit, we did the same for the full-fan and half-fan scanning modes, which were respectively used with the full bow-tie and half bow-tie filters. For XVI, the mean pixel values of regions of interest were found to generally decrease with increasing mAs for all protocols, while they were relatively stable with mAs for OBI. Noise was slightly lower on XVI and was seen to decrease with increasing mAs, while CNR increased with mAs for both systems. For XVI and OBI, the high-contrast resolution was approximately limited by the pixel resolution of the reconstructed image. On OBI images, up to 6 and 5 discs of 1% and 0.5% contrast, respectively, were visible for a high mAs setting using the full-fan mode, while none of the discs were clearly visible on the XVI images for various mAs settings when the medium resolution reconstruction was used. In conclusion, image quality parameters for XVI and OBI have been quantified and compared for clinical protocols under various mAs settings. These results need to be viewed in the context of a recent study that reported the dose-mAs relationship for the two systems and found that OBI generally delivered higher imaging doses than XVI.
Low dose dynamic myocardial CT perfusion using advanced iterative reconstruction
NASA Astrophysics Data System (ADS)
Eck, Brendan L.; Fahmi, Rachid; Fuqua, Christopher; Vembar, Mani; Dhanantwari, Amar; Bezerra, Hiram G.; Wilson, David L.
2015-03-01
Dynamic myocardial CT perfusion (CTP) can provide quantitative functional information for the assessment of coronary artery disease. However, x-ray dose in dynamic CTP is high, typically from 10mSv to >20mSv. We compared the dose reduction potential of advanced iterative reconstruction, Iterative Model Reconstruction (IMR, Philips Healthcare, Cleveland, Ohio) to hybrid iterative reconstruction (iDose4) and filtered back projection (FBP). Dynamic CTP scans were obtained using a porcine model with balloon-induced ischemia in the left anterior descending coronary artery to prescribed fractional flow reserve values. High dose dynamic CTP scans were acquired at 100kVp/100mAs with effective dose of 23mSv. Low dose scans at 75mAs, 50mAs, and 25mAs were simulated by adding x-ray quantum noise and detector electronic noise to the projection space data. Images were reconstructed with FBP, iDose4, and IMR at each dose level. Image quality in static CTP images was assessed by SNR and CNR. Blood flow was obtained using a dynamic CTP analysis pipeline and blood flow image quality was assessed using flow-SNR and flow-CNR. IMR showed highest static image quality according to SNR and CNR. Blood flow in FBP was increasingly over-estimated at reduced dose. Flow was more consistent for iDose4 from 100mAs to 50mAs, but was over-estimated at 25mAs. IMR was most consistent from 100mAs to 25mAs. Static images and flow maps for 100mAs FBP, 50mAs iDose4, and 25mAs IMR showed comparable, clear ischemia, CNR, and flow-CNR values. These results suggest that IMR can enable dynamic CTP at significantly reduced dose, at 5.8mSv or 25% of the comparable 23mSv FBP protocol.
Vachha, Behroze; Brodoefel, Harald; Wilcox, Carol; Hackney, David B; Moonis, Gul
2013-12-01
To compare objective and subjective image quality in neck CT images acquired at different tube current-time products (275 mAs and 340 mAs) and reconstructed with filtered-back-projection (FBP) and adaptive statistical iterative reconstruction (ASIR). HIPAA-compliant study with IRB approval and waiver of informed consent. 66 consecutive patients were randomly assigned to undergo contrast-enhanced neck CT at a standard tube-current-time-product (340 mAs; n = 33) or reduced tube-current-time-product (275 mAs, n = 33). Data sets were reconstructed with FBP and 2 levels (30%, 40%) of ASIR-FBP blending at 340 mAs and 275 mAs. Two neuroradiologists assessed subjective image quality in a blinded and randomized manner. Volume CT dose index (CTDIvol), dose-length-product (DLP), effective dose, and objective image noise were recorded. Signal-to-noise ratio (SNR) was computed as mean attenuation in a region of interest in the sternocleidomastoid muscle divided by image noise. Compared with FBP, ASIR resulted in a reduction of image noise at both 340 mAs and 275 mAs. Reduction of tube current from 340 mAs to 275 mAs resulted in an increase in mean objective image noise (p=0.02) and a decrease in SNR (p = 0.03) when images were reconstructed with FBP. However, when the 275 mAs images were reconstructed using ASIR, the mean objective image noise and SNR were similar to those of the standard 340 mAs CT images reconstructed with FBP (p>0.05). Subjective image noise was ranked by both raters as either average or less-than-average irrespective of the tube current and iterative reconstruction technique. Adapting ASIR into neck CT protocols reduced effective dose by 17% without compromising image quality. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
ON THE HUBBLE SPACE TELESCOPE TRIGONOMETRIC PARALLAX OF THE DWARF NOVA SS CYGNI
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nelan, Edmund P.; Bond, Howard E., E-mail: nelan@stsci.edu, E-mail: heb11@psu.edu
SS Cygni is one of the brightest dwarf novae (DNe), and one of the best studied prototypes of the cataclysmic variables. Astrometric observations with the Fine Guidance Sensors (FGSs) on the Hubble Space Telescope (HST), published in 2004, gave an absolute trigonometric parallax of 6.06 {+-} 0.44 mas. However, recent very long baseline interferometry (VLBI), obtained during radio outbursts of SS Cyg, has yielded a significantly larger absolute parallax of 8.80 {+-} 0.12 mas, as well as a large difference in the direction of the proper motion (PM) compared to the HST result. The VLBI distance reduces the implied luminositymore » of SS Cyg by about a factor of two, giving good agreement with predictions based on accretion-disk theory in order to explain the observed DN outburst behavior. This discrepancy raises the possibility of significant systematic errors in FGS parallaxes and PMs. We have reanalyzed the archival HST/FGS data, including (1) a critical redetermination of the parallaxes of the background astrometric reference stars, (2) updated input values of the reference-star PMs, and (3) correction of the position measurements for color-dependent shifts. Our new analysis yields a PM of SS Cyg that agrees well with the VLBI motion, and an absolute parallax of 8.30 {+-} 0.41 mas, also statistically concordant with the VLBI result at the {approx}1.2 {sigma} level. Our results suggest that HST/FGS parallaxes are free of large systematic errors, when the data are reduced using high-quality input values for the astrometry of the reference stars, and when instrumental signatures are properly removed.« less
NASA Astrophysics Data System (ADS)
Yan, Hao; Cervino, Laura; Jia, Xun; Jiang, Steve B.
2012-04-01
While compressed sensing (CS)-based algorithms have been developed for the low-dose cone beam CT (CBCT) reconstruction, a clear understanding of the relationship between the image quality and imaging dose at low-dose levels is needed. In this paper, we qualitatively investigate this subject in a comprehensive manner with extensive experimental and simulation studies. The basic idea is to plot both the image quality and imaging dose together as functions of the number of projections and mAs per projection over the whole clinically relevant range. On this basis, a clear understanding of the tradeoff between the image quality and imaging dose can be achieved and optimal low-dose CBCT scan protocols can be developed to maximize the dose reduction while minimizing the image quality loss for various imaging tasks in image-guided radiation therapy (IGRT). Main findings of this work include (1) under the CS-based reconstruction framework, image quality has little degradation over a large range of dose variation. Image quality degradation becomes evident when the imaging dose (approximated with the x-ray tube load) is decreased below 100 total mAs. An imaging dose lower than 40 total mAs leads to a dramatic image degradation, and thus should be used cautiously. Optimal low-dose CBCT scan protocols likely fall in the dose range of 40-100 total mAs, depending on the specific IGRT applications. (2) Among different scan protocols at a constant low-dose level, the super sparse-view reconstruction with the projection number less than 50 is the most challenging case, even with strong regularization. Better image quality can be acquired with low mAs protocols. (3) The optimal scan protocol is the combination of a medium number of projections and a medium level of mAs/view. This is more evident when the dose is around 72.8 total mAs or below and when the ROI is a low-contrast or high-resolution object. Based on our results, the optimal number of projections is around 90 to 120. (4) The clinically acceptable lowest imaging dose level is task dependent. In our study, 72.8 mAs is a safe dose level for visualizing low-contrast objects, while 12.2 total mAs is sufficient for detecting high-contrast objects of diameter greater than 3 mm.
Padole, Atul; Deedar Ali Khawaja, Ranish; Otrakji, Alexi; Zhang, Da; Liu, Bob; Xu, X George; Kalra, Mannudeep K
2016-05-01
The aim of this study was to compare the directly measured and the estimated computed tomography (CT) organ doses obtained from commercial radiation dose-tracking (RDT) software for CT performed with modulated tube current or automatic exposure control (AEC) technique and fixed tube current (mAs). With the institutional review board (IRB) approval, the ionization chambers were surgically implanted in a human cadaver (88 years old, male, 68 kg) in six locations such as liver, stomach, colon, left kidney, small intestine, and urinary bladder. The cadaver was scanned with routine abdomen pelvis protocol on a 128-slice, dual-source multidetector computed tomography (MDCT) scanner using both AEC and fixed mAs. The effective and quality reference mAs of 100, 200, and 300 were used for AEC and fixed mAs, respectively. Scanning was repeated three times for each setting, and measured and estimated organ doses (from RDT software) were recorded (N = 3*3*2 = 18). Mean CTDIvol for AEC and fixed mAs were 4, 8, 13 mGy and 7, 14, 21 mGy, respectively. The most estimated organ doses were significantly greater (P < 0.01) than the measured organ doses for both AEC and fixed mAs. At AEC, the mean estimated organ doses (for six organs) were 14.7 mGy compared to mean measured organ doses of 12.3 mGy. Similarly, at fixed mAs, the mean estimated organ doses (for six organs) were 24 mGy compared to measured organ doses of 22.3 mGy. The differences among the measured and estimated organ doses were higher for AEC technique compared to the fixed mAs for most organs (P < 0.01). The most CT organ doses estimated from RDT software are greater compared to directly measured organ doses, particularly when AEC technique is used for CT scanning. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Overall properties of the Gaia DR1 reference frame
NASA Astrophysics Data System (ADS)
Liu, N.; Zhu, Z.; Liu, J.-C.; Ding, C.-Y.
2017-03-01
Aims: The first Gaia data release (Gaia DR1) provides 2191 ICRF2 sources with their positions in the auxiliary quasar solution and five astrometric parameters - positions, parallaxes, and proper motions - for stars in common between the Tycho-2 catalogue and Gaia in the joint Tycho-Gaia astrometric solution (TGAS). We aim to analyze the overall properties of Gaia DR1 reference frame. Methods: We compare quasar positions of the auxiliary quasar solution with ICRF2 sources using different samples and evaluate the influence on the Gaia DR1 reference frame owing to the Galactic aberration effect over the J2000.0-J2015.0 period. Then we estimate the global rotation between TGAS with Tycho-2 proper motion systems to investigate the property of the Gaia DR1 reference frame. Finally, the Galactic kinematics analysis using the K-M giant proper motions is performed to understand the property of Gaia DR1 reference frame. Results: The positional comparison between the auxiliary quasar solution and ICRF2 shows negligible orientation and validates the declination bias of -0.1mas in Gaia quasar positions with respect to ICRF2. Galactic aberration effect is thought to cause an offset 0.01mas of the Z axis direction of Gaia DR1 reference frame. The global rotation between TGAS and Tycho-2 proper motion systems, obtained by different samples, shows a much smaller value than the claimed value 0.24mas yr-1. For the Galactic kinematics analysis of the TGAS K-M giants, we find possible non-zero Galactic rotation components beyond the classical Oort constants: the rigid part ωYG = -0.38±0.15mas yr-1 and the differential part ω^primeYG = -0.29±0.19mas yr-1 around the YG axis of Galactic coordinates, which indicates possible residual rotation in Gaia DR1 reference frame or problems in the current Galactic kinematical model. Conclusions: The Gaia DR1 reference frame is well aligned to ICRF2, and the possible influence of the Galactic aberration effect should be taken into consideration for the future Gaia-ICRF link. The cause of the rather small global rotation between TGAS and Tycho-2 proper motion systems is unclear and needs further investigation. The possible residual rotation in Gaia DR1 reference frame inferred from the Galactic kinematic analysis should be noted and examined in future data release.
Hussain, Fahad Ahmed; Mail, Noor; Shamy, Abdulrahman M; Suliman, Alghamdi; Saoudi, Abdelhamid
2016-05-08
Image quality is a key issue in radiology, particularly in a clinical setting where it is important to achieve accurate diagnoses while minimizing radiation dose. Some computed tomography (CT) manufacturers have introduced algorithms that claim significant dose reduction. In this study, we assessed CT image quality produced by two reconstruction algorithms provided with GE Healthcare's Discovery 690 Elite positron emission tomography (PET) CT scanner. Image quality was measured for images obtained at various doses with both conventional filtered back-projection (FBP) and adaptive statistical iterative reconstruction (ASIR) algorithms. A stan-dard CT dose index (CTDI) phantom and a pencil ionization chamber were used to measure the CT dose at 120 kVp and an exposure of 260 mAs. Image quality was assessed using two phantoms. CT images of both phantoms were acquired at tube voltage (kV) of 120 with exposures ranging from 25 mAs to 400 mAs. Images were reconstructed using FBP and ASIR ranging from 10% to 100%, then analyzed for noise, low-contrast detectability, contrast-to-noise ratio (CNR), and modulation transfer function (MTF). Noise was 4.6 HU in water phantom images acquired at 260 mAs/FBP 120 kV and 130 mAs/50% ASIR 120 kV. The large objects (fre-quency < 7 lp/cm) retained fairly acceptable image quality at 130 mAs/50% ASIR, compared to 260 mAs/FBP. The application of ASIR for small objects (frequency >7 lp/cm) showed poor visibility compared to FBP at 260 mAs and even worse for images acquired at less than 130 mAs. ASIR blending more than 50% at low dose tends to reduce contrast of small objects (frequency >7 lp/cm). We concluded that dose reduction and ASIR should be applied with close attention if the objects to be detected or diagnosed are small (frequency > 7 lp/cm). Further investigations are required to correlate the small objects (frequency > 7 lp/cm) to patient anatomy and clinical diagnosis.
Comparing the TYCHO Catalogue with CCD Astrograph Observations
NASA Astrophysics Data System (ADS)
Zacharias, N.; Hoeg, E.; Urban, S. E.; Corbin, T. E.
1997-08-01
Selected fields around radio-optical reference frame sources have been observed with the U.S. Naval Observatory CCD astrograph (UCA). This telescope is equipped with a red-corrected 206mm 5-element lens and a 4k by 4k CCD camera which provides a 1 square degree field of view. Positions with internal precisions of 20 mas for stars in the 7 to 12 magnitude range have been obtained with 30 second exposures. A comparison is made with the Tycho Catalogue, which is accurate to about 5 to 50 mas at mean epoch of J1991.25, depending on the magnitude of the star. Preliminary proper motions are obtained using the Astrographic Catalogue (AC) to update the Tycho positions to the epoch of the UCA observations, which adds an error contribution of about 15 to 20 mas. Individual CCD frames have been reduced with an average of 30 Tycho reference stars per frame. A linear plate model gives an average adjustment standard error of 46 mas, consistent with the internal errors. The UCA is capable of significantly improving the positions of Tycho stars fainter than about visual magnitude 9.5.
Mail, Noor; Shamy, Abdulrahman M.; Alghamdi, Suliman; Saoudi, Abdelhamid
2016-01-01
Image quality is a key issue in radiology, particularly in a clinical setting where it is important to achieve accurate diagnoses while minimizing radiation dose. Some computed tomography (CT) manufacturers have introduced algorithms that claim significant dose reduction. In this study, we assessed CT image quality produced by two reconstruction algorithms provided with GE Healthcare's Discovery 690 Elite positron emission tomography (PET) CT scanner. Image quality was measured for images obtained at various doses with both conventional filtered back‐projection (FBP) and adaptive statistical iterative reconstruction (ASIR) algorithms. A standard CT dose index (CTDI) phantom and a pencil ionization chamber were used to measure the CT dose at 120 kVp and an exposure of 260 mAs. Image quality was assessed using two phantoms. CT images of both phantoms were acquired at tube voltage (kV) of 120 with exposures ranging from 25 mAs to 400 mAs. Images were reconstructed using FBP and ASIR ranging from 10% to 100%, then analyzed for noise, low‐contrast detectability, contrast‐to‐noise ratio (CNR), and modulation transfer function (MTF). Noise was 4.6 HU in water phantom images acquired at 260 mAs/FBP 120 kV and 130 mAs/50% ASIR 120 kV. The large objects (frequency<7 lp/cm) retained fairly acceptable image quality at 130 mAs/50% ASIR, compared to 260 mAs/FBP. The application of ASIR for small objects (frequency>7 lp/cm) showed poor visibility compared to FBP at 260 mAs and even worse for images acquired at less than 130 mAs. ASIR blending more than 50% at low dose tends to reduce contrast of small objects (frequency>7 lp/cm). We concluded that dose reduction and ASIR should be applied with close attention if the objects to be detected or diagnosed are small (frequency>7 lp/cm). Further investigations are required to correlate the small objects (frequency>7 lp/cm) to patient anatomy and clinical diagnosis. PACS number(s): 87.57.‐s, 87.57.C, 87.57.cf, 87.57.cj, 87.57.cm, 87.57.cp, 87.57.N, 87.57.nf, 87.57.np, 87.57.nt, 87.57.Q, 87.59.‐e, 87.59.B PMID:27167261
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ramirez Giraldo, J; Mileto, A.; Hurwitz, L.
2014-06-15
Purpose: To evaluate the impact of body size and tube power limits in the optimization of fast scanning with high-pitch dual source CT (DSCT). Methods: A previously validated MERCURY phantom, made of polyethylene, with circular cross-section of diameters 16, 23, 30 and 37cm, and connected through tapered sections, was scanned using a second generation DSCT system. The DSCT operates with two independently controlled x-ray tube generators offering up to 200 kW power reserve (100 kW per tube). The entire length of the phantom (42cm) was scanned with two protocols using: A)Standard single-source CT (SSCT) protocol with pitch of 0.8, andmore » B) DSCT protocol with high-pitch values ranging from 1.6 to 3.2 (0.2 steps). All scans used 120 kVp with 150 quality reference mAs using automatic exposure control. Scanner radiation output (CTDIvol) and effective mAs values were extracted retrospectively from DICOM files for each slice. Image noise was recorded. All variables were assessed relative to phantom diameter. Results: With standard-pitch SSCT, the scanner radiation output (and tube-current) were progressively adapted with increasing size, from 6 mGy (120 mAs) up to 15 mGy (270 mAs) from the thinnest (16cm) to the thickest diameter (37 cm), respectively. By comparison, using high-pitch (3.2), the scanner output was bounded at about 8 mGy (140 mAs), independent of phantom diameter. Although relative to standard-pitch, the high-pitch led to lower radiation output for the same scan, the image noise was higher, particularly for larger diameters. To match the radiation output adaptation of standard-pitch, a high-pitch mode of 1.6 was needed, with the advantage of scanning twice as fast. Conclusion: To maximize the benefits of fast scanning with high-pitch DSCT, the body size and tube power limits of the system need to be considered such that a good balance between speed of acquisition and image quality are warranted. JCRG is an employee of Siemens Medical Solutions USA Inc.« less
Connection Between the ICRF and the Dynamical Reference Frame for the Outer Planets
NASA Astrophysics Data System (ADS)
da Silva Neto, D. N.; Assafin, M.; Andrei, A. H.; Vieira Martins, R.
2005-01-01
This work brings an approach intending to improve the connection between the Dynamical Reference Frame and the Extragalactic Reference Frame. For that, close encounters of outer Solar System objects and quasars are used. With this goal, Uranus, Neptune and two quasars were observed at Laborat´orio Nacional de Astrof´ısica (LNA), Brazil. The optical reference frame is the HCRF, as given by the UCAC2 catalogue. The first results show an accuracy of 45 mas - 50 mas in the optical positions. The optical minus radio offsets give the local orientation between the catalogue and radio frame. From this, it is possible to place the optical planet coordinates on the extragalactic frame. A comparison between the new corrected optical coordinates and the respective DE ephemeris to these planets can give the instant orientations of the Dynamical Reference Frame with regard to the ICRS, for this zone of outer Solar System.
NASA Technical Reports Server (NTRS)
Pena, Joaquin; Hinchey, Michael G.; Ruiz-Cortes, Antonio
2006-01-01
The field of Software Product Lines (SPL) emphasizes building a core architecture for a family of software products from which concrete products can be derived rapidly. This helps to reduce time-to-market, costs, etc., and can result in improved software quality and safety. Current AOSE methodologies are concerned with developing a single Multiagent System. We propose an initial approach to developing the core architecture of a Multiagent Systems Product Line (MAS-PL), exemplifying our approach with reference to a concept NASA mission based on multiagent technology.
NASA Technical Reports Server (NTRS)
Uffelman, Hal; Goodson, Troy; Pellegrin, Michael; Stavert, Lynn; Burk, Thomas; Beach, David; Signorelli, Joel; Jones, Jeremy; Hahn, Yungsun; Attiyah, Ahlam;
2009-01-01
The Maneuver Automation Software (MAS) automates the process of generating commands for maneuvers to keep the spacecraft of the Cassini-Huygens mission on a predetermined prime mission trajectory. Before MAS became available, a team of approximately 10 members had to work about two weeks to design, test, and implement each maneuver in a process that involved running many maneuver-related application programs and then serially handing off data products to other parts of the team. MAS enables a three-member team to design, test, and implement a maneuver in about one-half hour after Navigation has process-tracking data. MAS accepts more than 60 parameters and 22 files as input directly from users. MAS consists of Practical Extraction and Reporting Language (PERL) scripts that link, sequence, and execute the maneuver- related application programs: "Pushing a single button" on a graphical user interface causes MAS to run navigation programs that design a maneuver; programs that create sequences of commands to execute the maneuver on the spacecraft; and a program that generates predictions about maneuver performance and generates reports and other files that enable users to quickly review and verify the maneuver design. MAS can also generate presentation materials, initiate electronic command request forms, and archive all data products for future reference.
Gender agreement and multiple referents.
Finocchiaro, Chiara; Mahon, Bradford Z; Caramazza, Alfonso
2008-01-01
We report a new pattern of usage in current, spoken Italian that has implications for both psycholinguistic models of language production and linguistic theories of language change. In Italian, gender agreement is mandatory for both singular and plural nouns. However, when two or more nouns of different grammatical gender appear in a conjoined noun phrase (NP), masculine plural agreement is required. In this study, we combined on-line and off-line methodologies in order to assess the mechanisms involved in gender marking in the context of multiple referents. The results of two pronoun production tasks showed that plural feminine agreement was significantly more difficult than plural masculine agreement. In a separate study using offline judgements of acceptability, we found that agreement violations in Italian are tolerated more readily in the case of feminine conjoined noun phrases (e.g., la mela e la banana 'the:fem apple:fem and the: fem banana: fem') than masculine conjoined noun phrases (e.g., il fiore e il libro 'the:mas flower: mas and the:mas book:mas'). Implications of these results are discussed both at the level of functional architecture within the language production system and at the level of changes in language use.
NASA Astrophysics Data System (ADS)
Chen, Han; Danielsson, Mats; Xu, Cheng
2016-06-01
We are developing a photon-counting spectral CT detector with a small pixel size of 0.4× 0.5 mm2, offering a potential advantage for better visualization of small structures in pediatric patients. The purpose of this study is to determine the patient size dependent scanning parameters (kVp and mAs) for pediatric CT in two imaging cases: adipose imaging and iodinated blood imaging. Cylindrical soft-tissue phantoms of diameters between 10-25 cm were used to mimic patients of different ages from 0 to 15 y. For adipose imaging, a 5 mm diameter adipose sphere was assumed as an imaging target, while in the case of iodinated imaging, an iodinated blood sphere of 1 mm in diameter was assumed. By applying the geometry of a commercial CT scanner (GE Lightspeed VCT), simulations were carried out to calculate the detectability index, {{d}\\prime 2} , with tube potentials varying from 40 to 140 kVp. The optimal kVp for each phantom in each imaging case was determined such that the dose-normalized detectability index, {{d}\\prime 2}/ dose, is maximized. With the assumption that the detectability index in pediatric imaging is required the same as in typical adult imaging, the value of mAs at optimal kVp for each phantom was selected to achieve a reference detectability index that was obtained by scanning an adult phantom (30 cm in diameter) in a typical adult CT procedure (120 kVp and 200 mAs) using a modeled energy-integrating system. For adipose imaging, the optimal kVps are 50, 60, 80, and 120 kVp, respectively, for phantoms of 10, 15, 20, and 25 cm in diameter. The corresponding mAs values required to achieve the reference detectability index are only 9%, 23%, 24%, and 54% of the mAs that is used for adult patients at 120 kVp, for 10, 15, 20, and 25 cm diameter phantoms, respectively. In the case of iodinated imaging, a tube potential of 60 kVp was found optimal for all phantoms investigated, and the mAs values required to achieve the reference detectability index are 2%, 9%, 37%, and 109% of the adult mAs. The results also indicate that with the use of respective optimal kVps, the photon-counting spectral system offers up to 30% higher {{d}\\prime 2}/ dose than the modeled energy-integrating system for adipose imaging, and 70% for iodinated imaging.
NASA Astrophysics Data System (ADS)
Sharma, Kshama; Madhu, P. K.; Agarwal, Vipin
2016-09-01
The performance of heteronuclear spin decoupling sequences in solid-state NMR severely degrades when the proton radiofrequency (RF) nutation frequencies (ν1) are close to or at multiples of magic-angle spinning (MAS) frequency (νr) that are referred to as rotary-resonance recoupling conditions (ν1 = n · νr). Recently, two schemes, namely, PISSARRO and rCWApA, have been shown to be less affected by the problem of MAS and RF interference, specifically at the n = 2 rotary-resonance recoupling condition, especially in the fast MAS regime. Here, we systematically evaluate the loss in intensity of several heteronuclear spin decoupling sequences at the n = 1, 2 conditions compared to high-power decoupling in the fast-MAS regime. We propose that in the fast-MAS regime (above 40 kHz) the entire discussion about RF and MAS interference can be avoided by using appropriate low-power decoupling sequences which give comparable performance to decoupling sequences with high-power 1H irradiation of ca.195 kHz.
Gupta, Sandeep Kumar; Trethewey, Scott; Brooker, Bree; Rutherford, Natalie; Diffey, Jenny; Viswanathan, Suresh; Attia, John
2017-01-01
The CT component of SPECT-CT is required for attenuation correction and anatomical localization of the uptake on SPECT but there is no guideline about the optimal CT acquisition parameters. In our department, a standard CT acquisition protocol was changed in 2013 to give lower radiation dose to the patient. In this study, we retrospectively compared the effects on patient dose as well as the CT image quality with current versus older CT protocols. Ninety nine consecutive patients [n=51 Standard dose ‘old’ protocol (SDP); n=48 lower dose ‘new’ protocol (LDP)] with lumbar spine SPECT-CT for bone scan were examined. The main differences between the two protocols were that SDP used 130 kVp tube voltage and reference current-time product of 70 mAs whereas the LDP used 110 kVp and 40 mAs respectively. Various quantitative parameters from the CT images were obtained and the images were also rated blindly by two experienced nuclear medicine physicians for bony definition and noise. The mean calculated dose length product of the LDP group (121.5±39.6 mGy.cm) was significantly lower compared to the SDP group patients (266.9±96.9 mGy.cm; P<0.0001). This translated into a significant reduction in the mean effective dose to 1.8 mSv from 4.0 mSv. The physicians reported better CT image quality for the bony structures in LDP group although for soft tissue structures, the SDP group had better image quality. The optimized new CT acquisition protocol significantly reduced the radiation dose to the patient and in-fact improved CT image quality for the assessment of bony structures. PMID:28533938
Gudjonsdottir, J; Svensson, J R; Campling, S; Brennan, P C; Jonsdottir, B
2009-11-01
Image quality and radiation dose to the patient are important factors in computed tomography (CT). To provide constant image quality, tube current modulation (TCM) performed by automatic exposure control (AEC) adjusts the tube current to the patient's size and shape. To evaluate the effects of patient centering on tube current-time product (mAs) and image noise. An oval-shaped acrylic phantom was scanned in various off-center positions, at 30-mm intervals within a 500-mm field of view, using three different CT scanners. Acquisition parameters were similar to routine abdomen examinations at each site. The mAs was recorded and noise measured in the images. The correlation of mAs and noise with position was calculated using Pearson correlation. In all three scanners, the mAs delivered by the AEC changed with y-position of the phantom (P<0.001), with correlation values of 0.98 for scanners A and B and -0.98 for scanner C. With x-position, mAs changes were 4.9% or less. As the phantom moved into the y-positions, compared with the iso-center, the mAs varied by up to +70%, -34%, and +56% in scanners A, B, and C, respectively. For scanners A and B, noise in two regions of interest in the lower part of the phantom decreased with elevation, with correlation factors from -0.95 to -0.86 (P<0.02). In the x-direction, significant noise relationships (P<0.005) were only seen in scanner A. This study demonstrates that patient centering markedly affects the efficacy of AEC function and that tube current changes vary between scanners. Tube position when acquiring the scout projection radiograph is decisive for the direction of the mAs change. Off-center patient positions cause errors in tube current modulation that can outweigh the dose reduction gained by AEC use, and image quality is affected.
A Gaia-PS1-SDSS (GPS1) Proper Motion Catalog Covering 3/4 of the Sky
NASA Astrophysics Data System (ADS)
Tian, Hai-Jun; Gupta, Prashansa; Sesar, Branimir; Rix, Hans-Walter; Martin, Nicolas F.; Liu, Chao; Goldman, Bertrand; Platais, Imants; Kudritzki, Rolf-Peter; Waters, Christopher Z.
2017-09-01
We combine Gaia DR1, PS1, Sloan Digital Sky Survey (SDSS), and 2MASS astrometry to measure proper motions for 350 million sources across three-fourths of the sky down to a magnitude of {m}r˜ 20. Using positions of galaxies from PS1, we build a common reference frame for the multi-epoch PS1, single-epoch SDSS and 2MASS data, and calibrate the data in small angular patches to this frame. As the Gaia DR1 excludes resolved galaxy images, we choose a different approach to calibrate its positions to this reference frame: we exploit the fact that the proper motions of stars in these patches are linear. By simultaneously fitting the positions of stars at different epochs of—Gaia DR1, PS1, SDSS, and 2MASS—we construct an extensive catalog of proper motions dubbed GPS1. GPS1 has a characteristic systematic error of less than 0.3 {mas} {{yr}}-1 and a typical precision of 1.5-2.0 {mas} {{yr}}-1. The proper motions have been validated using galaxies, open clusters, distant giant stars, and QSOs. In comparison with other published faint proper motion catalogs, GPS1's systematic error (< 0.3 {mas} {{yr}}-1) should be nearly an order of magnitude better than that of PPMXL and UCAC4 (> 2.0 {mas} {{yr}}-1). Similarly, its precision (˜1.5 {mas} {{yr}}-1) is a four-fold improvement relative to PPMXL and UCAC4 (˜6.0 {mas} {{yr}}-1). For QSOs, the precision of GPS1 is found to be worse (˜2.0-3.0 {mas} {{yr}}-1), possibly due to their particular differential chromatic refraction. The GPS1 catalog will be released online and be available via the VizieR Service and VO Service.
Katsura, Morihiro; Kuriyama, Akira; Tada, Masafumi; Yamamoto, Kazumichi; Furukawa, Toshi A
2017-08-21
We are witnessing an explosive increase in redundant and overlapping publications of systematic reviews and meta-analyses (SRs/MAs) on the same topic, which often present conflicting results and interpretations, in the current medical literature. They represent wasted efforts on the part of investigators and peer reviewers and may confuse and possibly mislead clinicians and policymakers. Here, we present a protocol for a meta-epidemiological investigation to describe how often there are overlapping SRs/MAs on the same topic, to assess the quality of these multiple publications, and to investigate the causes of discrepant results between multiple SRs/MAs in the field of major surgery. We will use MEDLINE/PubMed to identify all SRs/MAs of randomised controlled trials (RCTs) published in 2015 regarding major surgical interventions. After identifying the 'benchmark' SRs/MAs published in 2015, a process of screening in MEDLINE will be carried out to identify the previous SRs/MAs of RCTs on the same topic that were published within 5 years of the 'benchmark' SRs/MAs. We will tabulate the number of previous SRs/MAs on the same topic of RCTs, and then describe their variations in numbers of RCTs included, sample sizes, effect size estimates and other characteristics. We will also assess the differences in quality of each SR/MA using A Measurement Tool to Assess Systematic Reviews (AMSTAR) score. Finally, we will investigate the potential reasons to explain the discrepant results between multiple SRs/MAs. No formal ethical approval and informed consent are required because this study will not collect primary individual data. The intended audiences of the findings include clinicians, healthcare researchers and policymakers. We will publish our findings as a scientific report in a peer-reviewed journal. In PROSPERO CRD42017059077, March 2017. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Bellesi, Luca; Wyttenbach, Rolf; Gaudino, Diego; Colleoni, Paolo; Pupillo, Francesco; Carrara, Mauro; Braghetti, Antonio; Puligheddu, Carla; Presilla, Stefano
2017-01-01
The aim of this work was to evaluate detection of low-contrast objects and image quality in computed tomography (CT) phantom images acquired at different tube loadings (i.e. mAs) and reconstructed with different algorithms, in order to find appropriate settings to reduce the dose to the patient without any image detriment. Images of supraslice low-contrast objects of a CT phantom were acquired using different mAs values. Images were reconstructed using filtered back projection (FBP), hybrid and iterative model-based methods. Image quality parameters were evaluated in terms of modulation transfer function; noise, and uniformity using two software resources. For the definition of low-contrast detectability, studies based on both human (i.e. four-alternative forced-choice test) and model observers were performed across the various images. Compared to FBP, image quality parameters were improved by using iterative reconstruction (IR) algorithms. In particular, IR model-based methods provided a 60% noise reduction and a 70% dose reduction, preserving image quality and low-contrast detectability for human radiological evaluation. According to the model observer, the diameters of the minimum detectable detail were around 2 mm (up to 100 mAs). Below 100 mAs, the model observer was unable to provide a result. IR methods improve CT protocol quality, providing a potential dose reduction while maintaining a good image detectability. Model observer can in principle be useful to assist human performance in CT low-contrast detection tasks and in dose optimisation.
Moderate MAS enhances local (1)H spin exchange and spin diffusion.
Roos, Matthias; Micke, Peter; Saalwächter, Kay; Hempel, Günter
2015-11-01
Proton NMR spin-diffusion experiments are often combined with magic-angle spinning (MAS) to achieve higher spectral resolution of solid samples. Here we show that local proton spin diffusion can indeed become faster at low (<10 kHz) spinning rates as compared to static conditions. Spin diffusion under static conditions can thus be slower than the often referred value of 0.8 nm(2)/ms, which was determined using slow MAS (Clauss et al., 1993). The enhancement of spin diffusion by slow MAS relies on the modulation of the orientation-dependent dipolar couplings during sample rotation and goes along with transient level crossings in combination with dipolar truncation. The experimental finding and its explanation is supported by density matrix simulations, and also emphasizes the sensitivity of spin diffusion to the local coupling topology. The amplification of spin diffusion by slow MAS cannot be explained by any model based on independent spin pairs; at least three spins have to be considered. Copyright © 2015 Elsevier Inc. All rights reserved.
Wood, T J; Avery, G; Balcam, S; Needler, L; Smith, A; Saunderson, J R; Beavis, A W
2015-01-01
Objective: The aim of this study was to investigate via simulation a proposed change to clinical practice for chest radiography. The validity of using a scatter rejection grid across the diagnostic energy range (60–125 kVp), in conjunction with appropriate tube current–time product (mAs) for imaging with a computed radiography (CR) system was investigated. Methods: A digitally reconstructed radiograph algorithm was used, which was capable of simulating CR chest radiographs with various tube voltages, receptor doses and scatter rejection methods. Four experienced image evaluators graded images with a grid (n = 80) at tube voltages across the diagnostic energy range and varying detector air kermas. These were scored against corresponding images reconstructed without a grid, as per current clinical protocol. Results: For all patients, diagnostic image quality improved with the use of a grid, without the need to increase tube mAs (and therefore patient dose), irrespective of the tube voltage used. Increasing tube mAs by an amount determined by the Bucky factor made little difference to image quality. Conclusion: A virtual clinical trial has been performed with simulated chest CR images. Results indicate that the use of a grid improves diagnostic image quality for average adults, without the need to increase tube mAs, even at low tube voltages. Advances in knowledge: Validated with images containing realistic anatomical noise, it is possible to improve image quality by utilizing grids for chest radiography with CR systems without increasing patient exposure. Increasing tube mAs by an amount determined by the Bucky factor is not justified. PMID:25571914
Paris, Françoise; Philibert, Pascal; Lumbroso, Serge; Servant, Nadège; Kalfa, Nicolas; Sultan, Charles
2009-01-01
Cushing's syndrome (CS) may develop at any time in childhood. In the neonatal period, the major cause is the overactivation of adrenal cells within the context of McCune-Albright syndrome (MAS). The hypercorticism usually appears with other clinical signs of MAS. We report here a case of isolated neonatal CS as the initial evidence of MAS. This newborn girl was referred to our pediatric endocrine unit at the age of 3 months for hypotonia and growth retardation. Clinical examination revealed facial plethora, moon face, and swollen limbs. Laboratory data demonstrated ACTH-independent CS. Magnetic resonance imaging showed moderate bilateral adrenal hyperplasia, though more marked in the left adrenal gland, without nodules. This peripheral hypercorticism without well-defined adrenal tumor was suggestive of MAS, although no other signs like precocious puberty or café-au-lait spots were found. An activating Gsalpha gene mutation was found on DNA extracted from blood. Because MAS is a somatic disease, usually with unilateral effects, we tried to remove only the larger adrenal gland, where the mutation was demonstrated. This female newborn later developed the classical triad of MAS, reinforcing this diagnosis. Cushing's syndrome in infants, even when isolated, may suggest a diagnosis of MAS. Copyright 2009 S. Karger AG, Basel.
VizieR Online Data Catalog: PMA Catalogue (Akhmetov+, 2017)
NASA Astrophysics Data System (ADS)
Akhmetov, V. S.; Fedorov, P. N.; Velichko, A. B.; Shulga, V. M.
2017-06-01
The idea for creating the catalogue is very simple. The PMA catalogue has been derived from a combination of two catalogues, namely 2MASS and Gaia DR1. The difference of epochs of observations for these catalogues is approximately 15 yr. The positions of objects in the Gaia DR1 catalogue are referred to the reference frame, which is consistent with ICRF to better than 0.1 mas for the J2015.0 epoch. The positions of objects in 2MASS are referred to HCRF, which, as was shown in Kovalevsky et al. (1997A&A...323..620K), is aligned with the ICRF to within ±0.6 mas at the epoch 1991.25 and is non-rotating with respect to distant extragalactic objects to within ±0.25mas/yr. By comparing the positions of the common objects contained in the catalogues, it is possible to determine their proper motions within their common range of stellar magnitudes by dividing differences of positions over the time interval between their observations. Formally, proper motions derived in such a way are given in the ICRF system, because the positions of both Gaia DR1 stars and those of 2MASS objects (through Hipparcos/Tycho-2 stars) are given in the ICRF and cover the whole sphere without gaps. We designate them further in this paper as relative, with the aim of discriminating them from absolute ones, which refer to the reference frame defined by the positions of about 1.6 million galaxies from Gaia DR1. There is no possibility of obtaining estimates of individual errors of proper motions of stars for the PMA Catalogue from the intrinsic convergence, because the direct errors for positions are not indicated in 2MASS. Therefore we use some indirect methods to obtain the estimates of uncertainties for proper motions. After elimination of the systematic errors, the root-mean-squared deviation of the coordinate differences of extended sources is about 200mas, and the mean number of galaxies inside each pixel is about 1300, so we expect the error of the absolute calibration to be 0.35mas/yr. We compared the proper motions of common objects from PMA and from the TGAS and UCAC4 catalogues. Knowing the mean-square errors of (PMA-TGAS) and (PMA-UCAC4) proper motion differences in each pixel, the appropriate errors in PMA vary from 2 to 10mas/yr, depending on magnitude, which are consistent with the errors calculated above. In case of any problems or questions, please contact by e-mail V.S. Akhmetov (akhmetovvs(at)gmail.com or akhmetov(at)astron.kharkov.ua). (1 data file).
M855A1 Enhanced Performance Round (EPR) Media Day
2011-05-04
Distribution is unlimited. Other requests shall be referred to the Office of the Project Manager for Maneuver Ammunition Systems, ATTN: SFAE-AMO-MAS- SETI ... SETI ,Picatinny,NJ,07806-5000 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR/MONITOR’S...the Project Manager for Maneuver Ammunition Systems, ATTN: SFAE- AMO-MAS- SETI , Picatinny, NJ Distribution Statement A: Approved for Public Release
Gomez-Cardona, Daniel; Li, Ke; Hsieh, Jiang; Lubner, Meghan G; Pickhardt, Perry J; Chen, Guang-Hong
2016-02-01
Phantom-based objective image quality assessment methods are widely used in the medical physics community. For a filtered backprojection (FBP) reconstruction-based linear or quasilinear imaging system, the use of this methodology is well justified. Many key image quality metrics acquired with phantom studies can be directly applied to in vivo human subject studies. Recently, a variety of image quality metrics have been investigated for model-based iterative image reconstruction (MBIR) methods and several novel characteristics have been discovered in phantom studies. However, the following question remains unanswered: can certain results obtained from phantom studies be generalized to in vivo animal studies and human subject studies? The purpose of this paper is to address this question. One of the most striking results obtained from phantom studies is a novel power-law relationship between noise variance of MBIR (σ(2)) and tube current-rotation time product (mAs): σ(2) ∝ (mAs)(-0.4) [K. Li et al., "Statistical model based iterative reconstruction (MBIR) in clinical CT systems: Experimental assessment of noise performance," Med. Phys. 41, 041906 (15pp.) (2014)]. To examine whether the same power-law works for in vivo cases, experimental data from two types of in vivo studies were analyzed in this paper. All scans were performed with a 64-slice diagnostic CT scanner (Discovery CT750 HD, GE Healthcare) and reconstructed with both FBP and a MBIR method (Veo, GE Healthcare). An Institutional Animal Care and Use Committee-approved in vivo animal study was performed with an adult swine at six mAs levels (10-290). Additionally, human subject data (a total of 110 subjects) acquired from an IRB-approved clinical trial were analyzed. In this clinical trial, a reduced-mAs scan was performed immediately following the standard mAs scan; the specific mAs used for the two scans varied across human subjects and were determined based on patient size and clinical indications. The measurements of σ(2) were performed at different mAs by drawing regions-of-interest (ROIs) in the liver and the subcutaneous fat. By applying a linear least-squares regression, the β values in the power-law relationship σ(2) ∝ (mAs)(-β) were measured for the in vivo data and compared with the value found in phantom experiments. For the in vivo swine study, an exponent of β = 0.43 was found for MBIR, and the coefficient of determination (R(2)) for the corresponding least-squares power-law regression was 0.971. As a reference, the β and R(2) values for FBP were found to be 0.98 and 0.997, respectively, from the same study, which are consistent with the well-known σ(2) ∝ (mAs)(-1.0) relationship for linear CT systems. For the human subject study, the measured β values for the MBIR images were 0.41 ± 0.12 in the liver and 0.37 ± 0.12 in subcutaneous fat. In comparison, the β values for the FBP images were 1.04 ± 0.10 in the liver and 0.97 ± 0.12 in subcutaneous fat. The β values of MBIR and FBP obtained from the in vivo studies were found to be statistically equivalent to the corresponding β values from the phantom study within an equivalency interval of [ - 0.1, 0.1] (p < 0.05); across MBIR and FBP, the difference in β was statistically significant (p < 0.05). Despite the nonlinear nature of the MBIR method, the power-law relationship, σ(2) ∝ (mAs)(-0.4), found from phantom studies can be applied to in vivo animal and human subject studies.
Men, Kuo; Dai, Jianrong
2017-12-01
To develop a projection quality-driven tube current modulation method in cone-beam computed tomography for image-guided radiotherapy based on the prior attenuation information obtained by the planning computed tomography and then evaluate its effect on a reduction in the imaging dose. The QCKV-1 phantom with different thicknesses (0-400 mm) of solid water upon it was used to simulate different attenuation (μ). Projections were acquired with a series of tube current-exposure time product (mAs) settings, and a 2-dimensional contrast to noise ratio was analyzed for each projection to create a lookup table of mAs versus 2-dimensional contrast to noise ratio, μ. Before a patient underwent computed tomography, the maximum attenuation [Formula: see text] within the 95% range of each projection angle (θ) was estimated according to the planning computed tomography images. Then, a desired 2-dimensional contrast to noise ratio value was selected, and the mAs setting at θ was calculated with the lookup table of mAs versus 2-dimensional contrast to noise ratio,[Formula: see text]. Three-dimensional cone-beam computed tomography images were reconstructed using the projections acquired with the selected mAs. The imaging dose was evaluated with a polymethyl methacrylate dosimetry phantom in terms of volume computed tomography dose index. Image quality was analyzed using a Catphan 503 phantom with an oval body annulus and a pelvis phantom. For the Catphan 503 phantom, the cone-beam computed tomography image obtained by the projection quality-driven tube current modulation method had a similar quality to that of conventional cone-beam computed tomography . However, the proposed method could reduce the imaging dose by 16% to 33% to achieve an equivalent contrast to noise ratio value. For the pelvis phantom, the structural similarity index was 0.992 with a dose reduction of 39.7% for the projection quality-driven tube current modulation method. The proposed method could reduce the additional dose to the patient while not degrading the image quality for cone-beam computed tomography. The projection quality-driven tube current modulation method could be especially beneficial to patients who undergo cone-beam computed tomography frequently during a treatment course.
Radio-Optical Reference Frame Link Using the U.S. Naval Observatory Astrograph and Deep CCD Imaging
NASA Astrophysics Data System (ADS)
Zacharias, N.; Zacharias, M. I.
2014-05-01
Between 1997 and 2004 several observing runs were conducted, mainly with the CTIO 0.9 m, to image International Celestial Reference Frame (ICRF) counterparts (mostly QSOs) in order to determine accurate optical positions. Contemporary to these deep CCD images, the same fields were observed with the U.S. Naval Observatory astrograph in the same bandpass. They provide accurate positions on the Hipparcos/Tycho-2 system for stars in the 10-16 mag range used as reference stars for the deep CCD imaging data. Here we present final optical position results of 413 sources based on reference stars obtained by dedicated astrograph observations that were reduced following two different procedures. These optical positions are compared to radio very long baseline interferometry positions. The current optical system is not perfectly aligned to the ICRF radio system with rigid body rotation angles of 3-5 mas (= 3σ level) found between them for all three axes. Furthermore, statistically, the optical-radio position differences are found to exceed the total, combined, known errors in the observations. Systematic errors in the optical reference star positions and physical offsets between the centers of optical and radio emissions are both identified as likely causes. A detrimental, astrophysical, random noise component is postulated to be on about the 10 mas level. If confirmed by future observations, this could severely limit the Gaia to ICRF reference frame alignment accuracy to an error of about 0.5 mas per coordinate axis with the current number of sources envisioned to provide the link. A list of 36 ICRF sources without the detection of an optical counterpart to a limiting magnitude of about R = 22 is provided as well.
Radio-optical reference frame link using the U.S. Naval observatory astrograph and deep CCD imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zacharias, N.; Zacharias, M. I., E-mail: nz@usno.navy.mil
2014-05-01
Between 1997 and 2004 several observing runs were conducted, mainly with the CTIO 0.9 m, to image International Celestial Reference Frame (ICRF) counterparts (mostly QSOs) in order to determine accurate optical positions. Contemporary to these deep CCD images, the same fields were observed with the U.S. Naval Observatory astrograph in the same bandpass. They provide accurate positions on the Hipparcos/Tycho-2 system for stars in the 10-16 mag range used as reference stars for the deep CCD imaging data. Here we present final optical position results of 413 sources based on reference stars obtained by dedicated astrograph observations that were reducedmore » following two different procedures. These optical positions are compared to radio very long baseline interferometry positions. The current optical system is not perfectly aligned to the ICRF radio system with rigid body rotation angles of 3-5 mas (= 3σ level) found between them for all three axes. Furthermore, statistically, the optical-radio position differences are found to exceed the total, combined, known errors in the observations. Systematic errors in the optical reference star positions and physical offsets between the centers of optical and radio emissions are both identified as likely causes. A detrimental, astrophysical, random noise component is postulated to be on about the 10 mas level. If confirmed by future observations, this could severely limit the Gaia to ICRF reference frame alignment accuracy to an error of about 0.5 mas per coordinate axis with the current number of sources envisioned to provide the link. A list of 36 ICRF sources without the detection of an optical counterpart to a limiting magnitude of about R = 22 is provided as well.« less
Ab Razak, N H; Praveena, S M; Aris, A Z; Hashim, Z
2016-02-01
Information about the quality of drinking water, together with analysis of knowledge, attitude and practice (KAP) analysis and health risk assessment (HRA) remain limited. The aims of this study were: (1) to ascertain the level of KAP regarding heavy metal contamination of drinking water in Pasir Mas; (2) to determine the concentration of heavy metals (Al, Cr, Cu, Fe, Ni, Pb, Zn and Cd) in drinking water in Pasir Mas; and (3) to estimate the health risks (non-carcinogenic and carcinogenic) caused by heavy metal exposure through drinking water using hazard quotient and lifetime cancer risk. Information on KAP was collected using a standardized questionnaire. Heavy metal analysis of drinking water samples was performed using graphite furnace atomic absorption spectrophotometry. The population of Pasir Mas has good knowledge (80%), a less positive attitude (93%) and good practice (81%) towards heavy metal contamination of drinking water. The concentrations of heavy metals analysed in this study were found to be below the permissible limits for drinking water set by the Malaysian Ministry of Health and the World Health Organization. The HRA showed no potential non-carcinogenic and carcinogenic risks from the intake of heavy metal through drinking water. By investigating the quality of drinking water, KAP and HRA, the results of this study will provide authorities with the knowledge and resources to improve the management of drinking water quality in the future. Copyright © 2015 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.
Ming, Dan; Chen, Qunlin; Yang, Wenjing; Chen, Rui; Wei, Dongtao; Li, Wenfu; Qiu, Jiang; Xu, Zhan; Zhang, Qinglin
2016-01-01
The motive to achieve success (MAS) and motive to avoid failure (MAF) are two different but classical kinds of achievement motivation. Though many functional magnetic resonance imaging studies have explored functional activation in motivation-related conditions, research has been silent as to the brain structures associated with individual differences in achievement motivation, especially with respect to MAS and MAF. In this study, the voxel-based morphometry method was used to uncover focal differences in brain structures related to MAS and MAF measured by the Mehrabian Achieving Tendency Scale in 353 healthy young Chinese adults. The results showed that the brain structures associated with individual differences in MAS and MAF were distinct. MAS was negatively correlated with regional gray matter volume (rGMV) in the medial prefrontal cortex (mPFC)/orbitofrontal cortex while MAF was negatively correlated with rGMV in the mPFC/subgenual cingulate gyrus. After controlling for mutual influences of MAS and MAF scores, MAS scores were found to be related to rGMV in the mPFC/orbitofrontal cortex and another cluster containing the parahippocampal gyrus and precuneus. These results may predict that compared with MAF, the generation process of MAS may be more complex and rational, thus in the real world, perhaps MAS is more beneficial to personal growth and guaranteeing the quality of task performance.
Scholkmann, F; Spichtig, S; Muehlemann, T; Wolf, M
2010-05-01
Near-infrared imaging (NIRI) is a neuroimaging technique which enables us to non-invasively measure hemodynamic changes in the human brain. Since the technique is very sensitive, the movement of a subject can cause movement artifacts (MAs), which affect the signal quality and results to a high degree. No general method is yet available to reduce these MAs effectively. The aim was to develop a new MA reduction method. A method based on moving standard deviation and spline interpolation was developed. It enables the semi-automatic detection and reduction of MAs in the data. It was validated using simulated and real NIRI signals. The results show that a significant reduction of MAs and an increase in signal quality are achieved. The effectiveness and usability of the method is demonstrated by the improved detection of evoked hemodynamic responses. The present method can not only be used in the postprocessing of NIRI signals but also for other kinds of data containing artifacts, for example ECG or EEG signals.
Linking Deep Astrometric Standards to the ICRF
NASA Astrophysics Data System (ADS)
Frey, S.; Platais, I.; Fey, A. L.
2007-07-01
The next-generation large aperature and large field-of-view telescopes will address fundamantal questions of astrophysica and cosmology such as the nature of dark matter and dark energy. For a variety of applications, the CCD mosaic detectors in the focal plane arrays require astronomic calibrationat the milli-arcsecond (mas) level. The existing optical reference frames are insufficient to support such calibrations. To address this problem, deep optical astronomic fields are being established near the Galactic plane. In order to achiev a 5-10-mas or better positional accuracyfor the Deepp Astrometric Standards (DAS), and to obtain bsolute stellar proper motions for the study of Galactic structure, it is crucial to link these fields to the International Celestial Reference Frame (ICRF). To this end, we selected 15 candidate compact extragalactic radio sources in the Gemini-Orion-Taurus (GOT) field. These sources were observed with the European VLBI Network (EVN) at 5 GHz in phase-reference mode. The bright compact calibrator source J0603+2159 and seven other sources were detected and imaged at the angular resolution of -1.5-8 mas. Relative astrometric positions were derived for these sources at a milli-arcsecond accuracy level. The detection of the optical counterparts of these extragalactic radio sources will allow us to establish a direct link to the ICRF locally in the GOT field.
Lin, Jhih-Tsong; Chen, Yan-Cheng; Wu, Shih-Chieh; Hwang, Sheue-Ling
2017-01-01
In an advanced nuclear power plant (NPP), the operators are responsible for monitoring a massive number of alarm parameters. To assist the operators, a monitoring-aid system (MAS), that applies four quality control chart methods, was proposed and evaluated. Two types of MAS, namely, text and graph marks, were proposed and compared with the original display. To validate the proposed MAS, 17 professional engineers and operators were invited to join an experiment. Two different system states, normal and abnormal, were simulated. The operators were asked to manipulate the system, monitor the critical parameters, search for operational procedures, and deal with other secondary tasks. The primary and secondary task performance and heart rate were measured. After each task was conducted, three subjective rating questionnaires, namely, mental workload, situation awareness, and preference ratings, were implemented for the proposed MAS and the original system. With the assistance of the MAS, the alarm detection rate, secondary task performance, and subjective mental workload demonstrate significant improvements. The proposed MAS helps the operators monitor critical parameters. Therefore, the MAS should be considered for implementation with the control panel to increase the safety of NPPs. Furthermore, the MAS could reduce the mental workload might decrease the health hazard of the operators.
Quality of reporting of systematic reviews published in “evidence-based” Chinese journals
2014-01-01
Background The number of systematic reviews (SRs)/meta-analyses (MAs) has increased dramatically in China over the past decades. However, evaluation of quality of reporting of systematic reviews published has not been undertaken. The objective of this study is to evaluate the quality of reporting of SRs/MAs assessing efficacy and/or harms of clinical interventions published in “evidence-based” Chinese journals. Methods Web-based database searches were conducted for the Chinese Journal of Evidence-based Medicine, the Journal of Evidence-Based Medicine, the Chinese Journal of Evidence Based Pediatrics, and the Chinese Journal of Evidence-Based Cardiovascular Medicine. SRs/MAs assessing efficacy and/or harms of clinical interventions were included. The cut-off was December 31st 2011. The PRISMA statement was applied to assess the quality of reporting. Each item was assessed as follows: ‘Yes’ for total compliance, scored ‘1’; ‘partial’ for partial compliance, scored ‘0.5’; and ‘No’ for non-compliance, scored ‘0’. The review was considered to have major flaws if it received a total score of ≤15.0, minor flaws if it received a total score of 15.5 to 21.0, and minimal flaws if it received a total score 21.5 to 27.0. Odds ratios were used for binary variables, and the mean difference was used for continuous variables. Analyses were performed using RevMan 5.0 software. Results Overall, 487 SRs/MAs were identified and assessed. The included reviews had medium quality with minor flaws based on PRISMA total scores (range: 8.5–26.0; mean: 19.6 ± 3.3). The stratified analysis showed that SRs/MAs with more than 3 authors, from a university, hospital + university cooperation, multiple affiliations (≥2), and funding have significantly higher quality of reporting of SRs/MAs; 58% of the included reviews were considered to have minor flaws (total score of 15.6 to 21.0). Only 9.6% of reviews were considered to have major flaws. Specific areas needing improvement in reporting include the abstract, protocol and registration, and characteristics of the search. Conclusions The reporting of SRs published in “evidence-based” Chinese journals is poor and needs to be improved in order for reviews to be useful. SR authors should use the PRISMA checklist to ensure complete and accurate accounts of their SRs. PMID:24906805
Joseph, Olufunmilayo O.; Loto, Cleophas A.; Sivaprasad, Seetharaman; Ajayi, John A.; Tarafder, Soumitra
2016-01-01
In this study, micro-alloyed steel (MAS) material normally used in the production of auto parts has been immersed in an E80 simulated fuel grade ethanol (SFGE) environment and its degradation mechanism in the presence of sodium chloride (NaCl) was evaluated. Corrosion behavior was determined through mass loss tests and electrochemical measurements with respect to a reference test in the absence of NaCl. Fracture behavior was determined via J-integral tests with three-point bend specimens at an ambient temperature of 27 °C. The mass loss of MAS increased in E80 with NaCl up to a concentration of 32 mg/L; beyond that threshold, the effect of increasing chloride was insignificant. MAS did not demonstrate distinct passivation behavior, as well as pitting potential with anodic polarization, in the range of the ethanol-chloride ratio. Chloride caused pitting in MAS. The fracture resistance of MAS reduced in E80 with increasing chloride. Crack tip blunting decreased with increasing chloride, thus accounting for the reduction in fracture toughness. PMID:28773601
Digital radiography: optimization of image quality and dose using multi-frequency software.
Precht, H; Gerke, O; Rosendahl, K; Tingberg, A; Waaler, D
2012-09-01
New developments in processing of digital radiographs (DR), including multi-frequency processing (MFP), allow optimization of image quality and radiation dose. This is particularly promising in children as they are believed to be more sensitive to ionizing radiation than adults. To examine whether the use of MFP software reduces the radiation dose without compromising quality at DR of the femur in 5-year-old-equivalent anthropomorphic and technical phantoms. A total of 110 images of an anthropomorphic phantom were imaged on a DR system (Canon DR with CXDI-50 C detector and MLT[S] software) and analyzed by three pediatric radiologists using Visual Grading Analysis. In addition, 3,500 images taken of a technical contrast-detail phantom (CDRAD 2.0) provide an objective image-quality assessment. Optimal image-quality was maintained at a dose reduction of 61% with MLT(S) optimized images. Even for images of diagnostic quality, MLT(S) provided a dose reduction of 88% as compared to the reference image. Software impact on image quality was found significant for dose (mAs), dynamic range dark region and frequency band. By optimizing image processing parameters, a significant dose reduction is possible without significant loss of image quality.
Earth Rotation Parameter Solutions using BDS and GPS Data from MEGX Network
NASA Astrophysics Data System (ADS)
Xu, Tianhe; Yu, Sumei; Li, Jiajing; He, Kaifei
2014-05-01
Earth rotation parameters (ERPs) are necessary parameters to achieve mutual transformation of the celestial reference frame and earth-fix reference frame. They are very important for satellite precise orbit determination (POD), high-precision space navigation and positioning. In this paper, the determination of ERPs including polar motion (PM), polar motion rate (PMR) and length of day (LOD) are presented using BDS and GPS data of June 2013 from MEGX network based on least square (LS) estimation with constraint condition. BDS and GPS data of 16 co-location stations from MEGX network are the first time used to estimate the ERPs. The results show that the RMSs of x and y component errors of PM and PM rate are about 0.9 mas, 1.0 mas, 0.2 mas/d and 0.3 mas/d respectively using BDS data. The RMS of LOD is about 0.03 ms/d using BDS data. The RMSs of x and y component errors of PM and PM rate are about 0.2 mas, 0.2 mas/d respectively using GPS data. The RMS of LOD is about 0.02 ms/d using GPS data. The optimal relative weight is determined by using variance component estimation when combining BDS and GPS data. The accuracy improvements of adding BDS data is between 8% to 20% for PM and PM rate. There is no obvious improvement in LOD when BDS data is involved. System biases between BDS and GPS are also resolved per station. They are very stable from day to day with the average accuracy of about 20 cm. Keywords: Earth rotation parameter; International GNSS Service; polar motion; length of day; least square with constraint condition Acknowledgments: This work was supported by Natural Science Foundation of China (41174008) and the Foundation for the Author of National Excellent Doctoral Dissertation of China (2007B51) .
Brorfelde Schmidt CCD Catalog (BSCC)
2010-06-23
reference stars. Errors of individual positions are about 20 to 200 mas for stars in the R = 10 to 18 mag range. External comparisons with 2MASS and SDSS...reveal possible small systematic errors in the BSCC of up to about 30 mas. The catalog is supplemented with J, H, and Ks magnitudes from the 2MASS ...Survey ( 2MASS ) near-infrared photometry added to the catalog (2). The fil- ters used at the Brorfelde Schmidt for this project are approximating the
Sanz-Cabanillas, Juan Luis; Ruano, Juan; Gomez-Garcia, Francisco; Alcalde-Mellado, Patricia; Gay-Mimbrera, Jesus; Aguilar-Luque, Macarena; Maestre-Lopez, Beatriz; Gonzalez-Padilla, Marcelino; Carmona-Fernandez, Pedro J; Velez Garcia-Nieto, Antonio; Isla-Tejera, Beatriz
2017-01-01
Moderate-to-severe psoriasis is associated with significant comorbidity, an impaired quality of life, and increased medical costs, including those associated with treatments. Systematic reviews (SRs) and meta-analyses (MAs) of randomized clinical trials are considered two of the best approaches to the summarization of high-quality evidence. However, methodological bias can reduce the validity of conclusions from these types of studies and subsequently impair the quality of decision making. As co-authorship is among the most well-documented forms of research collaboration, the present study aimed to explore whether authors' collaboration methods might influence the methodological quality of SRs and MAs of psoriasis. Methodological quality was assessed by two raters who extracted information from full articles. After calculating total and per-item Assessment of Multiple Systematic Reviews (AMSTAR) scores, reviews were classified as low (0-4), medium (5-8), or high (9-11) quality. Article metadata and journal-related bibliometric indices were also obtained. A total of 741 authors from 520 different institutions and 32 countries published 220 reviews that were classified as high (17.2%), moderate (55%), or low (27.7%) methodological quality. The high methodological quality subnetwork was larger but had a lower connection density than the low and moderate methodological quality subnetworks; specifically, the former contained relatively fewer nodes (authors and reviews), reviews by authors, and collaborators per author. Furthermore, the high methodological quality subnetwork was highly compartmentalized, with several modules representing few poorly interconnected communities. In conclusion, structural differences in author-paper affiliation network may influence the methodological quality of SRs and MAs on psoriasis. As the author-paper affiliation network structure affects study quality in this research field, authors who maintain an appropriate balance between scientific quality and productivity are more likely to develop higher quality reviews.
Progressive cone beam CT dose control in image-guided radiation therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yan Hao; Cervino, Laura; Jiang, Steve B.
2013-06-15
Purpose: Cone beam CT (CBCT) in image-guided radiotherapy (IGRT) offers a tremendous advantage for treatment guidance. The associated imaging dose is a clinical concern. One unique feature of CBCT-based IGRT is that the same patient is repeatedly scanned during a treatment course, and the contents of CBCT images at different fractions are similar. The authors propose a progressive dose control (PDC) scheme to utilize this temporal correlation for imaging dose reduction. Methods: A dynamic CBCT scan protocol, as opposed to the static one in the current clinical practice, is proposed to gradually reduce the imaging dose in each treatment fraction.more » The CBCT image from each fraction is processed by a prior-image based nonlocal means (PINLM) module to enhance its quality. The increasing amount of prior information from previous CBCT images prevents degradation of image quality due to the reduced imaging dose. Two proof-of-principle experiments have been conducted using measured phantom data and Monte Carlo simulated patient data with deformation. Results: In the measured phantom case, utilizing a prior image acquired at 0.4 mAs, PINLM is able to improve the image quality of a CBCT acquired at 0.2 mAs by reducing the noise level from 34.95 to 12.45 HU. In the synthetic patient case, acceptable image quality is maintained at four consecutive fractions with gradually decreasing exposure levels of 0.4, 0.1, 0.07, and 0.05 mAs. When compared with the standard low-dose protocol of 0.4 mAs for each fraction, an overall imaging dose reduction of more than 60% is achieved. Conclusions: PINLM-PDC is able to reduce CBCT imaging dose in IGRT utilizing the temporal correlations among the sequence of CBCT images while maintaining the quality.« less
Nishiyama, Y.; Kobayashi, T.; Malon, M.; ...
2015-02-16
Two-dimensional 1H{ 13C} heteronuclear correlation solid-state NMR spectra of naturally abundant solid materials are presented, acquired using the 0.75-mm magic angle spinning (MAS) probe at spinning rates up to 100 kHz. In spite of the miniscule sample volume (290 nL), high-quality HSQC-type spectra of bulk samples as well as surface-bound molecules can be obtained within hours of experimental time. The experiments are compared with those carried out at 40 kHz MAS using a 1.6-mm probe, which offered higher overall sensitivity due to a larger rotor volume. The benefits of ultrafast MAS in such experiments include superior resolution in 1H dimensionmore » without resorting to 1H– 1H homonuclear RF decoupling, easy optimization, and applicability to mass-limited samples. As a result, the HMQC spectra of surface-bound species can be also acquired under 100 kHz MAS, although the dephasing of transverse magnetization has significant effect on the efficiency transfer under MAS alone.« less
Evaluation of the effect of low tube voltage on radiation dose and image quality
NASA Astrophysics Data System (ADS)
Norhasrina Nik Din, Nik; Zainon, Rafidah; Rahman, A. T. Abdul
2017-05-01
Number of Computed Tomography (CT) examinations performed worldwide is increasing. In 2010, the FDA issued an initiative to reduce unnecessary radiation exposure from CT imaging. The aim of this study is to evaluate the effect of low tube voltage on radiation dose and image quality using CTDI phantom. The CTDI phantom was scanned with dual energy CT at 80 kV and 120 kV with the tube current from 150 mAs to 350 mAs. Pitch was 1.0 while slice thickness was 1 mm and 5 mm. Results show if mAs was increased, the SNR values also will be increased. The 5 mm slice thickness shows higher SNR value compared to 1 mm slice thickness. As the voltage and tube current increased, the amount of dose absorbed is also increased because current is proportional to photon flux.
First results of DORIS data analysis at Geodetic Observatory Pecný
NASA Astrophysics Data System (ADS)
Štěpánek, Petr; Hugentobler, Urs; Le Bail, Karine
2006-11-01
In a cooperation between the Astronomical Institute, University of Bern (AIUB), the Geodetic Observatory Pecný (GOPE), and the Institut Géographique National (IGN), DORIS data analysis capabilities were implemented into a development version of the Bernese GPS software. The DORIS Doppler observables are reformulated such that they are similar to global navigation satellite system (GNSS) carrier-phase observations, allowing the use of the same observation models and algorithms as for GNSS carrier-phase data analysis with only minor software modifications. As such, the same algorithms may be used to process DORIS carrier-phase observations. First results from the analysis of 3 weeks of DORIS data (September 2004, five DORIS-equipped satellites) at GOPE are promising and are presented here. They include the comparison of station coordinates with coordinate estimates derived by the Laboratoire d’Etudes en Géophysique et Océanographie Spatiale/Collecte Localisation Satellites analysis centre (LCA) and the Institut Géographique National/Jet Propulsion Laboratory (IGN/JPL), and the comparison of Earth orientation parameters (EOPs) with the International Earth Rotation and Reference Frames Service (IERS) C04 model. The modified Bernese results are of a slightly lower, but comparable, quality than corresponding solutions routinely computed within the IDS (International DORIS Service). The weekly coordinate repeatability RMS is of the order of 2 3 cm for each 3D station coordinate. Comparison with corresponding estimates of station coordinates from current IDS analysis centers demonstrates similar precision. Daily pole component estimates show a mean difference from IERS-C04 of 0.6 mas in X p and - 0.5 mas in Y p and a RMS of 0.8 mas in X p and 0.9 mas in Y p (mean removed). An automatic analysis procedure is under development at GOPE, and routine DORIS data processing will be implemented in the near future.
Pecetti, Luciano; Brummer, E. Charles; Palmonari, Alberto; Tava, Aldo
2017-01-01
Genetic progress for forage quality has been poor in alfalfa (Medicago sativa L.), the most-grown forage legume worldwide. This study aimed at exploring opportunities for marker-assisted selection (MAS) and genomic selection of forage quality traits based on breeding values of parent plants. Some 154 genotypes from a broadly-based reference population were genotyped by genotyping-by-sequencing (GBS), and phenotyped for leaf-to-stem ratio, leaf and stem contents of protein, neutral detergent fiber (NDF) and acid detergent lignin (ADL), and leaf and stem NDF digestibility after 24 hours (NDFD), of their dense-planted half-sib progenies in three growing conditions (summer harvest, full irrigation; summer harvest, suspended irrigation; autumn harvest). Trait-marker analyses were performed on progeny values averaged over conditions, owing to modest germplasm × condition interaction. Genomic selection exploited 11,450 polymorphic SNP markers, whereas a subset of 8,494 M. truncatula-aligned markers were used for a genome-wide association study (GWAS). GWAS confirmed the polygenic control of quality traits and, in agreement with phenotypic correlations, indicated substantially different genetic control of a given trait in stems and leaves. It detected several SNPs in different annotated genes that were highly linked to stem protein content. Also, it identified a small genomic region on chromosome 8 with high concentration of annotated genes associated with leaf ADL, including one gene probably involved in the lignin pathway. Three genomic selection models, i.e., Ridge-regression BLUP, Bayes B and Bayesian Lasso, displayed similar prediction accuracy, whereas SVR-lin was less accurate. Accuracy values were moderate (0.3–0.4) for stem NDFD and leaf protein content, modest for leaf ADL and NDFD, and low to very low for the other traits. Along with previous results for the same germplasm set, this study indicates that GBS data can be exploited to improve both quality traits (by genomic selection or MAS) and forage yield. PMID:28068350
Biazzi, Elisa; Nazzicari, Nelson; Pecetti, Luciano; Brummer, E Charles; Palmonari, Alberto; Tava, Aldo; Annicchiarico, Paolo
2017-01-01
Genetic progress for forage quality has been poor in alfalfa (Medicago sativa L.), the most-grown forage legume worldwide. This study aimed at exploring opportunities for marker-assisted selection (MAS) and genomic selection of forage quality traits based on breeding values of parent plants. Some 154 genotypes from a broadly-based reference population were genotyped by genotyping-by-sequencing (GBS), and phenotyped for leaf-to-stem ratio, leaf and stem contents of protein, neutral detergent fiber (NDF) and acid detergent lignin (ADL), and leaf and stem NDF digestibility after 24 hours (NDFD), of their dense-planted half-sib progenies in three growing conditions (summer harvest, full irrigation; summer harvest, suspended irrigation; autumn harvest). Trait-marker analyses were performed on progeny values averaged over conditions, owing to modest germplasm × condition interaction. Genomic selection exploited 11,450 polymorphic SNP markers, whereas a subset of 8,494 M. truncatula-aligned markers were used for a genome-wide association study (GWAS). GWAS confirmed the polygenic control of quality traits and, in agreement with phenotypic correlations, indicated substantially different genetic control of a given trait in stems and leaves. It detected several SNPs in different annotated genes that were highly linked to stem protein content. Also, it identified a small genomic region on chromosome 8 with high concentration of annotated genes associated with leaf ADL, including one gene probably involved in the lignin pathway. Three genomic selection models, i.e., Ridge-regression BLUP, Bayes B and Bayesian Lasso, displayed similar prediction accuracy, whereas SVR-lin was less accurate. Accuracy values were moderate (0.3-0.4) for stem NDFD and leaf protein content, modest for leaf ADL and NDFD, and low to very low for the other traits. Along with previous results for the same germplasm set, this study indicates that GBS data can be exploited to improve both quality traits (by genomic selection or MAS) and forage yield.
[Application of Low Dose Spiral CT in Diagnosing Impacted Teeth in Children and Adolescents].
Wang, Meng-tian; Li, Xue-sheng; Li, Kai-ming; Bao, Li; Ning, Gang
2015-09-01
[ABSTRACT] To determine the value of low dose spiral CT scanning in diagnosing impacted teeth of children and adolescents. A total of 153 children and adolescents with confirmed impacted teeth in West China Second University Hospital, Sichuan University were enrolled in this study. They were divided into 5 groups according to the different spiral CT scan parameters (tube current time product, scanning thickness and collimation value): Group A (n=30, 330 mAs, 6 X 0. 75 mm and 3. 0 mm), Group B (n=30, 140 mAs, 6 X 0. 75 mm and 3. 0 mm), Group C (n=30, 80 mAs, 6 X 0. 75 mm and 3. 0 mm), Group D (n=31, 80 mAs, 6 X 1. 50 mm and 5. 0 mm), and Group E (n=32, 50 mAs, 6 X 1. 50 mm and 5. 0 mm). There were no significant differences in general clinical features (P>0. 05) among the participants of the five groups. The phantoms were used to measure spatial resolution and contrast resolution of the scan images. Dose length product (DLP) was recorded during CT scanning for calculating effective dose (ED) of exposure. The quality of images was evaluated using a list of quality scoring criteria. (1) Under 330, 140, 80, 80 and 50 mAs, the images had a spatial resolution of 1.0 mm, with contrast resolution of 2. 0, 3. 0, 4. 5, 4. 5 and 6. 0 mm, respectively. (2) Significant differences in ED values were found among the five groups (F=1 064. 119, P=0. 000) and between every two of those groups (P<0. 05). Group E had the lowest ED (0. 19 mSv), 86. 52%, 67. 24%, 45. 71%, and 38. 71% lower than that in Group A, B, C and D, respectively (P<0. 05). (3) All of the five groups obtained an image quality score above 3, and no statistical differences appeared among the 5 groupl (F=1. 978, P>0. 05). The diagnostic results of the spiral CT were consistent with those of orthodontic surgery. Low dose spiral CT scanning can meet the image quality requirements for diagnosing impacted teeth, minimizing radiation exposure effectively.
Multi-Atlas Segmentation of Biomedical Images: A Survey
Iglesias, Juan Eugenio; Sabuncu, Mert R.
2015-01-01
Multi-atlas segmentation (MAS), first introduced and popularized by the pioneering work of Rohlfing, Brandt, Menzel and Maurer Jr (2004), Klein, Mensh, Ghosh, Tourville and Hirsch (2005), and Heckemann, Hajnal, Aljabar, Rueckert and Hammers (2006), is becoming one of the most widely-used and successful image segmentation techniques in biomedical applications. By manipulating and utilizing the entire dataset of “atlases” (training images that have been previously labeled, e.g., manually by an expert), rather than some model-based average representation, MAS has the flexibility to better capture anatomical variation, thus offering superior segmentation accuracy. This benefit, however, typically comes at a high computational cost. Recent advancements in computer hardware and image processing software have been instrumental in addressing this challenge and facilitated the wide adoption of MAS. Today, MAS has come a long way and the approach includes a wide array of sophisticated algorithms that employ ideas from machine learning, probabilistic modeling, optimization, and computer vision, among other fields. This paper presents a survey of published MAS algorithms and studies that have applied these methods to various biomedical problems. In writing this survey, we have three distinct aims. Our primary goal is to document how MAS was originally conceived, later evolved, and now relates to alternative methods. Second, this paper is intended to be a detailed reference of past research activity in MAS, which now spans over a decade (2003 – 2014) and entails novel methodological developments and application-specific solutions. Finally, our goal is to also present a perspective on the future of MAS, which, we believe, will be one of the dominant approaches in biomedical image segmentation. PMID:26201875
Is minimal access spine surgery more cost-effective than conventional spine surgery?
Lubelski, Daniel; Mihalovich, Kathryn E; Skelly, Andrea C; Fehlings, Michael G; Harrop, James S; Mummaneni, Praveen V; Wang, Michael Y; Steinmetz, Michael P
2014-10-15
Systematic review. To summarize and critically review the economic literature evaluating the cost-effectiveness of minimal access surgery (MAS) compared with conventional open procedures for the cervical and lumbar spine. MAS techniques may improve perioperative parameters (length of hospital stay and extent of blood loss) compared with conventional open approaches. However, some have questioned the clinical efficacy of these differences and the associated cost-effectiveness implications. When considering the long-term outcomes, there seem to be no significant differences between MAS and open surgery. PubMed, EMBASE, the Cochrane Collaboration database, University of York, Centre for Reviews and Dissemination (NHS-EED and HTA), and the Tufts CEA Registry were reviewed to identify full economic studies comparing MAS with open techniques prior to December 24, 2013, based on the key questions established a priori. Only economic studies that evaluated and synthesized the costs and consequences of MAS compared with conventional open procedures (i.e., cost-minimization, cost-benefit, cost-effectiveness, or cost-utility) were considered for inclusion. Full text of the articles meeting inclusion criteria were reviewed by 2 independent investigators to obtain the final collection of included studies. The Quality of Health Economic Studies instrument was scored by 2 independent reviewers to provide an initial basis for critical appraisal of included economic studies. The search strategy yielded 198 potentially relevant citations, and 6 studies met the inclusion criteria, evaluating the costs and consequences of MAS versus conventional open procedures performed for the lumbar spine; no studies for the cervical spine met the inclusion criteria. Studies compared MAS tubular discectomy with conventional microdiscectomy, minimal access transforaminal lumbar interbody fusion versus open transforaminal lumbar interbody fusion, and multilevel hemilaminectomy via MAS versus open approach. Overall, the included cost-effectiveness studies generally supported no significant differences between open surgery and MAS lumbar approaches. However, these conclusions are preliminary because there was a paucity of high-quality evidence. Much of the evidence lacked details on methodology for modeling, related assumptions, justification of economic model chosen, and sources and types of included costs and consequences. The follow-up periods were highly variable, indirect costs were not frequently analyzed or reported, and many of the studies were conducted by a single group, thereby limiting generalizability. Prospective studies are needed to define differences and optimal treatment algorithms. 3.
Methodological Quality Assessment of Meta-Analyses of Hyperthyroidism Treatment.
Qin, Yahong; Yao, Liang; Shao, Feifei; Yang, Kehu; Tian, Limin
2018-01-01
Hyperthyroidism is a common condition that is associated with increased morbidity and mortality. A number of meta-analyses (MAs) have assessed the therapeutic measures for hyperthyroidism, including antithyroid drugs, surgery, and radioiodine, however, the methodological quality has not been evaluated. This study evaluated the methodological quality and summarized the evidence obtained from MAs of hyperthyroidism treatments for radioiodine, antithyroid drugs, and surgery. We searched the PubMed, EMBASE, Cochrane Library, Web of Science, and Chinese Biomedical Literature Database databases. Two investigators independently assessed the meta-analyses titles and abstracts for inclusion. Methodological quality was assessed using the validated AMSTAR (Assessing the Methodological Quality of Systematic Reviews) tool. A total of 26 MAs fulfilled the inclusion criteria. Based on the AMSTAR scores, the average methodological quality was 8.31, with large variability ranging from 4 to 11. The methodological quality of English meta-analyses was better than that of Chinese meta-analyses. Cochrane reviews had better methodological quality than non-Cochrane reviews due to better study selection and data extraction, the inclusion of unpublished studies, and better reporting of study characteristics. The authors did not report conflicts of interest in 53.8% meta-analyses, and 19.2% did not report the harmful effects of treatment. Publication bias was not assessed in 38.5% of meta-analyses, and 19.2% did not report the follow-up time. Large-scale assessment of methodological quality of meta-analyses of hyperthyroidism treatment highlighted methodological strengths and weaknesses. Consideration of scientific quality when formulating conclusions should be made explicit. Future meta-analyses should improve on reporting conflict of interest. © Georg Thieme Verlag KG Stuttgart · New York.
Astrometric Quality of the USNO CCD Astrograph (UCA)
NASA Astrophysics Data System (ADS)
Zacharias, N.
1997-05-01
The USNO 8-inch astrograph has been equipped with a Kodak 1536x1024 pixel CCD since June 1995, operating in a 570-650 nm bandpass. With 3-minute exposures well exposed images are obtained in the magnitude range R ~ 8.5 - 13.5(m) . An astrometric precision of 10 to 15 mas for those stars is estimated from frame-to-frame comparisons. External comparisons reveal an accuracy of about 15 mas for those stars in a 20' field of view. For fainter stars, the error budget is dominated by the S/N ratio, reaching ~ 100 mas at R=16(m) under good observing conditions.
Almeida, Fernanda R.; Mulgrew, Alan; Ayas, Najib; Tsuda, Hiroko; Lowe, Alan A.; Fox, Nurit; Harrison, Sandra; Fleetham, John A.
2013-01-01
Study Objectives: CPAP is used as the first-line treatment for patients with severe OSA, but this machine is not always feasible to use on the long term. We performed a clinical trial to determine whether patients with OSA could use a mandibular advancement splint (MAS) as a short-term treatment alternative to CPAP. Methods: Twenty-two patients adherent with CPAP therapy were recruited to the study. Each patient used the MAS for approximately 4 months. The transition between CPAP to MAS was gradual, and patients were asked to start using MAS together with CPAP during the MAS titration until subjective improvement or maximum mandibular advancement was achieved. Sleepiness (ESS), quality of life (SAQLI), and polysomnography were recorded prior to and after MAS titration. Patients recorded CPAP or MAS usage for the following 3 months. Results: Seven women and 12 men with a mean age of 53.8 (± 12.1) years and mean body mass index of 28.1 (± 4.8) kg/m2 completed the clinical trial. Prior to MAS, CPAP adherence was 5.8 h/night. AHI decreased significantly with MAS use compared to baseline (30.7 ± 23.1 vs 13.2 ± 11; p < 0.01). Fourteen patients (74%) had > 50% decrease in their AHI, while 2 patients had an increase in their AHI. There were no significant differences in SAQLI between MAS and CPAP treatment, while ESS decreased significantly on MAS. MAS self-reported usage was correlated with treatment efficacy (r = 0.52; p < 0.05). Seventy-five percent of the patients reported being sufficiently satisfied with MAS to continue to use it as an alternative short-term therapy. Conclusions: MAS partially or completely reduced sleep disordered breathing in the majority of selected, successfully CPAP-treated severe OSA patients. Many patients can probably effectively use MAS as a short-term treatment alternative to CPAP. Clinical Trial Registration: ClinicalTrials.gov registration number NCT00358605. Commentary: A commentary on this article appears in this issue on page 325. Citation: Almeida FR; Mulgrew A; Ayas N; Tsuda H; Lowe AA; Fox N; Harrison S; Fleetham JA. Mandibular advancement splint as short-term alternative treatment in patients with obstructive sleep apnea already effectively treated with continuous positive airway pressure. J Clin Sleep Med 2013;9(4):319-324. PMID:23585745
THE CELESTIAL REFERENCE FRAME AT 24 AND 43 GHz. I. ASTROMETRY
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lanyi, G. E.; Jacobs, C. S.; Naudet, C. J.
2010-05-15
We present astrometric results for compact extragalactic objects observed with the Very Long Baseline Array at radio frequencies of 24 and 43 GHz. Data were obtained from ten 24 hr observing sessions made over a five-year period. These observations were motivated by the need to extend the International Celestial Reference Frame (ICRF) to higher radio frequencies to enable improved deep space navigation after 2016 and to improve state-of-the-art astrometry. Source coordinates for 268 sources were estimated at 24 GHz and for 131 sources at 43 GHz. The median formal uncertainties of right ascension and declination at 24 GHz are 0.08more » and 0.15 mas, respectively. Median formal uncertainties at 43 GHz are 0.20 and 0.35 mas, respectively. Weighted root-mean-square differences between the 24 and 43 GHz positions and astrometric positions based on simultaneous 2.3 and 8.4 GHz Very Long Baseline Interferometry observations, such as the ICRF, are less than about 0.3 mas in both coordinates. With observations over five years we have achieved a precision at 24 GHz approaching that of the ICRF but unaccounted systematic errors limit the overall accuracy of the catalogs.« less
Gomez-Garcia, Francisco; Alcalde-Mellado, Patricia; Gay-Mimbrera, Jesus; Aguilar-Luque, Macarena; Maestre-Lopez, Beatriz; Gonzalez-Padilla, Marcelino; Carmona-Fernandez, Pedro J.; Velez Garcia-Nieto, Antonio; Isla-Tejera, Beatriz
2017-01-01
Moderate-to-severe psoriasis is associated with significant comorbidity, an impaired quality of life, and increased medical costs, including those associated with treatments. Systematic reviews (SRs) and meta-analyses (MAs) of randomized clinical trials are considered two of the best approaches to the summarization of high-quality evidence. However, methodological bias can reduce the validity of conclusions from these types of studies and subsequently impair the quality of decision making. As co-authorship is among the most well-documented forms of research collaboration, the present study aimed to explore whether authors’ collaboration methods might influence the methodological quality of SRs and MAs of psoriasis. Methodological quality was assessed by two raters who extracted information from full articles. After calculating total and per-item Assessment of Multiple Systematic Reviews (AMSTAR) scores, reviews were classified as low (0-4), medium (5-8), or high (9-11) quality. Article metadata and journal-related bibliometric indices were also obtained. A total of 741 authors from 520 different institutions and 32 countries published 220 reviews that were classified as high (17.2%), moderate (55%), or low (27.7%) methodological quality. The high methodological quality subnetwork was larger but had a lower connection density than the low and moderate methodological quality subnetworks; specifically, the former contained relatively fewer nodes (authors and reviews), reviews by authors, and collaborators per author. Furthermore, the high methodological quality subnetwork was highly compartmentalized, with several modules representing few poorly interconnected communities. In conclusion, structural differences in author-paper affiliation network may influence the methodological quality of SRs and MAs on psoriasis. As the author-paper affiliation network structure affects study quality in this research field, authors who maintain an appropriate balance between scientific quality and productivity are more likely to develop higher quality reviews. PMID:28403245
Salazar, Juan A; Pacheco, Igor; Shinya, Paulina; Zapata, Patricio; Silva, Claudia; Aradhya, Mallikarjuna; Velasco, Dianne; Ruiz, David; Martínez-Gómez, Pedro; Infante, Rodrigo
2017-01-01
Marker-assisted selection (MAS) in stone fruit ( Prunus species) breeding is currently difficult to achieve due to the polygenic nature of the most relevant agronomic traits linked to fruit quality. Genotyping by sequencing (GBS), however, provides a large quantity of useful data suitable for fine mapping using Single Nucleotide Polymorphisms (SNPs) from a reference genome. In this study, GBS was used to genotype 272 seedlings of three F1 Japanese plum ( Prunus salicina Lindl) progenies derived from crossing "98-99" (as a common female parent) with "Angeleno," "September King," and "September Queen" as male parents. Raw sequences were aligned to the Peach genome v1, and 42,909 filtered SNPs were obtained after sequence alignment. In addition, 153 seedlings from the "98-99" × "Angeleno" cross were used to develop a genetic map for each parent. A total of 981 SNPs were mapped (479 for "98-99" and 502 for "Angeleno"), covering a genetic distance of 688.8 and 647.03 cM, respectively. Fifty five seedlings from this progeny were phenotyped for different fruit quality traits including ripening time, fruit weight, fruit shape, chlorophyll index, skin color, flesh color, over color, firmness, and soluble solids content in the years 2015 and 2016. Linkage-based QTL analysis allowed the identification of genomic regions significantly associated with ripening time (LG4 of both parents and both phenotyping years), fruit skin color (LG3 and LG4 of both parents and both years), chlorophyll degradation index (LG3 of both parents in 2015) and fruit weight (LG7 of both parents in 2016). These results represent a promising situation for GBS in the identification of SNP variants associated to fruit quality traits, potentially applicable in breeding programs through MAS, in a highly heterozygous crop species such as Japanese plum.
Shin, Hyun Joo; Lee, Young Han; Choi, Jin-Young; Park, Mi-Suk; Kim, Myeong-Jin; Kim, Ki Whang
2013-01-01
Objective To evaluate the feasibility of sinogram-affirmed iterative reconstruction (SAFIRE) and automated kV modulation (CARE kV) in reducing radiation dose without increasing image noise for abdominal CT examination. Materials and Methods This retrospective study included 77 patients who received CT imaging with an application of CARE kV with or without SAFIRE and who had comparable previous CT images obtained without CARE kV or SAFIRE, using the standard dose (i.e., reference mAs of 240) on an identical CT scanner and reconstructed with filtered back projection (FBP) within 1 year. Patients were divided into two groups: group A (33 patients, CT scanned with CARE kV); and group B (44 patients, scanned after reducing the reference mAs from 240 to 170 and applying both CARE kV and SAFIRE). CT number, image noise for four organs and radiation dose were compared among the two groups. Results Image noise increased after CARE kV application (p < 0.001) and significantly decreased as SAFIRE strength increased (p < 0.001). Image noise with reduced-mAs scan (170 mAs) in group B became similar to that of standard-dose FBP images after applying CARE kV and SAFIRE strengths of 3 or 4 when measured in the aorta, liver or muscle (p ≥ 0.108). Effective doses decreased by 19.4% and 41.3% for groups A and B, respectively (all, p < 0.001) after application of CARE kV with or without SAFIRE. Conclusion Combining CARE kV, reduction of mAs from 240 to 170 mAs and noise reduction by applying SAFIRE strength 3 or 4 reduced the radiation dose by 41.3% without increasing image noise compared with the standard-dose FBP images. PMID:24265563
Li, Li; Tacke, Eckhard; Hofferbert, Hans-Reinhardt; Lübeck, Jens; Strahwald, Josef; Draffehn, Astrid M; Walkemeier, Birgit; Gebhardt, Christiane
2013-04-01
Tuber yield, starch content, starch yield and chip color are complex traits that are important for industrial uses and food processing of potato. Chip color depends on the quantity of reducing sugars glucose and fructose in the tubers, which are generated by starch degradation. Reducing sugars accumulate when tubers are stored at low temperatures. Early and efficient selection of cultivars with superior yield, starch yield and chip color is hampered by the fact that reliable phenotypic selection requires multiple year and location trials. Application of DNA-based markers early in the breeding cycle, which are diagnostic for superior alleles of genes that control natural variation of tuber quality, will reduce the number of clones to be evaluated in field trials. Association mapping using genes functional in carbohydrate metabolism as markers has discovered alleles of invertases and starch phosphorylases that are associated with tuber quality traits. Here, we report on new DNA variants at loci encoding ADP-glucose pyrophosphorylase and the invertase Pain-1, which are associated with positive or negative effect with chip color, tuber starch content and starch yield. Marker-assisted selection (MAS) and marker validation were performed in tetraploid breeding populations, using various combinations of 11 allele-specific markers associated with tuber quality traits. To facilitate MAS, user-friendly PCR assays were developed for specific candidate gene alleles. In a multi-parental population of advanced breeding clones, genotypes were selected for having different combinations of five positive and the corresponding negative marker alleles. Genotypes combining five positive marker alleles performed on average better than genotypes with four negative alleles and one positive allele. When tested individually, seven of eight markers showed an effect on at least one quality trait. The direction of effect was as expected. Combinations of two to three marker alleles were identified that significantly improved average chip quality after cold storage and tuber starch content. In F1 progeny of a single-cross combination, MAS with six markers did not give the expected result. Reasons and implications for MAS in potato are discussed.
Tugwell, J R; England, A; Hogg, P
2017-08-01
Physical and technical differences exist between imaging on an x-ray tabletop and imaging on a trolley. This study evaluates how trolley imaging impacts image quality and radiation dose for an antero-posterior (AP) pelvis projection whilst subsequently exploring means of optimising this imaging examination. An anthropomorphic pelvis phantom was imaged on a commercially available trolley under various conditions. Variables explored included two mattresses, two image receptor holder positions, three source to image distances (SIDs) and four mAs values. Image quality was evaluated using relative visual grading analysis with the reference image acquired on the x-ray tabletop. Contrast to noise ratio (CNR) was calculated. Effective dose was established using Monte Carlo simulation. Optimisation scores were derived as a figure of merit by dividing effective dose with visual image quality scores. Visual image quality reduced significantly (p < 0.05) whilst effective dose increased significantly (p < 0.05) for images acquired on the trolley using identical acquisition parameters to the reference image. The trolley image with the highest optimisation score was acquired using 130 cm SID, 20 mAs, the standard mattress and platform not elevated. A difference of 12.8 mm was found between the image with the lowest and highest magnification factor (18%). The acquisition parameters used for AP pelvis on the x-ray tabletop are not transferable to trolley imaging and should be modified accordingly to compensate for the differences that exist. Exposure charts should be developed for trolley imaging to ensure optimal image quality at lowest possible dose. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.
SU-E-I-56: Threshold Effect of ASIR Before Which Image Improve and After Which Image Degrades.
Abdulkhaliq, F; Mail, N; Saoudi, A
2012-06-01
This study showed to what extent ASIR improves CT-image and to what extent it degrades it. In our study we used GE HD750 CT-scanner, Siemens Sensation CT-scanner, Catphan, PTW-pin-ion- chamber, CTDI-phantom. We measured the CT-dose using the PTW-pinion-chamber and CTDI-phantom. Image-quality and noise were evaluated using catphan and GE water phantom. Image noise reduce as higher levels of ASIR are applied. A phantom scan showed that 50%ASIR with 50% lower-dose (10.8mGy) achieved the same image noise of standard FBP image with full dose 21.7mGy (noise∼5). To confirm that the two same-noise images retain same image-quality, two scans were compared; one with full dose 260mAs(21.7mGy) and the other one with 50% lower dose 130mAs(10.8mGy). The results showed that ASIR failed to retain the same quality. For high contrast resolution, 50%ASIR reduced the resolution of patterns = 71p/cm, however it improved the detectability of patterns = 61p/cm. ASIR has degraded the CNR of the low-contrast-objects of = 5HU (CNR of 1.4 at 260mAs STND to CNR of 1.08 at 130mAs ASIR), however it improved the CNR of the low-contrast-objects of = 10HU (CNR of 2.35 at 260mAs STND to CNR of 2.63 at 130mAs ASIR). ASIR degraded the edges and killed some of the small objects. This shows that ASIR has a critical point of improve/degrade. Also, ASIR can improve images for the same dose, but with high levels of ASIR (e.g. 100%ASIR), cause disapear of small low contrast objects (e.g. 2mm). People think that ASIR only improves image and reduces patient dose. Our study showed that ASIR has some drawbacks. There is a threshold before wich ASIR is positive and after which ASIR is negative. Recently only GE provide ASIR in the market but our study showed that other CTs such as Siemens can do similar performance like ASIR. © 2012 American Association of Physicists in Medicine.
Team-based primary care: The medical assistant perspective.
Sheridan, Bethany; Chien, Alyna T; Peters, Antoinette S; Rosenthal, Meredith B; Brooks, Joanna Veazey; Singer, Sara J
Team-based care has the potential to improve primary care quality and efficiency. In this model, medical assistants (MAs) take a more central role in patient care and population health management. MAs' traditionally low status may give them a unique view on changing organizational dynamics and teamwork. However, little empirical work exists on how team-based organizational designs affect the experiences of low-status health care workers like MAs. The aim of this study was to describe how team-based primary care affects the experiences of MAs. A secondary aim was to explore variation in these experiences. In late 2014, the authors interviewed 30 MAs from nine primary care practices transitioning to team-based care. Interviews addressed job responsibilities, teamwork, implementation, job satisfaction, and learning. Data were analyzed using a thematic networks approach. Interviews also included closed-ended questions about workload and job satisfaction. Most MAs reported both a higher workload (73%) and a greater job satisfaction (86%) under team-based primary care. Interview data surfaced four mechanisms for these results, which suggested more fulfilling work and greater respect for the MA role: (a) relationships with colleagues, (b) involvement with patients, (c) sense of control, and (d) sense of efficacy. Facilitators and barriers to these positive changes also emerged. Team-based care can provide low-status health care workers with more fulfilling work and strengthen relationships across status lines. The extent of this positive impact may depend on supporting factors at the organization, team, and individual worker levels. To maximize the benefits of team-based care, primary care leaders should recognize the larger role that MAs play under this model and support them as increasingly valuable team members. Contingent on organizational conditions, practices may find MAs who are willing to manage the increased workload that often accompanies team-based care.
Precise Orbital and Geodetic Parameter Estimation using SLR Observations for ILRS AAC
NASA Astrophysics Data System (ADS)
Kim, Young-Rok; Park, Eunseo; Oh, Hyungjik Jay; Park, Sang-Young; Lim, Hyung-Chul; Park, Chandeok
2013-12-01
In this study, we present results of precise orbital geodetic parameter estimation using satellite laser ranging (SLR) observations for the International Laser Ranging Service (ILRS) associate analysis center (AAC). Using normal point observations of LAGEOS-1, LAGEOS-2, ETALON-1, and ETALON-2 in SLR consolidated laser ranging data format, the NASA/ GSFC GEODYN II and SOLVE software programs were utilized for precise orbit determination (POD) and finding solutions of a terrestrial reference frame (TRF) and Earth orientation parameters (EOPs). For POD, a weekly-based orbit determination strategy was employed to process SLR observations taken from 20 weeks in 2013. For solutions of TRF and EOPs, loosely constrained scheme was used to integrate POD results of four geodetic SLR satellites. The coordinates of 11 ILRS core sites were determined and daily polar motion and polar motion rates were estimated. The root mean square (RMS) value of post-fit residuals was used for orbit quality assessment, and both the stability of TRF and the precision of EOPs by external comparison were analyzed for verification of our solutions. Results of post-fit residuals show that the RMS of the orbits of LAGEOS-1 and LAGEOS-2 are 1.20 and 1.12 cm, and those of ETALON-1 and ETALON-2 are 1.02 and 1.11 cm, respectively. The stability analysis of TRF shows that the mean value of 3D stability of the coordinates of 11 ILRS core sites is 7.0 mm. An external comparison, with respect to International Earth rotation and Reference systems Service (IERS) 08 C04 results, shows that standard deviations of polar motion XP and YP are 0.754 milliarcseconds (mas) and 0.576 mas, respectively. Our results of precise orbital and geodetic parameter estimation are reasonable and help advance research at ILRS AAC.
Rapid estimation of 4DCT motion-artifact severity based on 1D breathing-surrogate periodicity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Guang, E-mail: lig2@mskcc.org; Caraveo, Marshall; Wei, Jie
2014-11-01
Purpose: Motion artifacts are common in patient four-dimensional computed tomography (4DCT) images, leading to an ill-defined tumor volume with large variations for radiotherapy treatment and a poor foundation with low imaging fidelity for studying respiratory motion. The authors developed a method to estimate 4DCT image quality by establishing a correlation between the severity of motion artifacts in 4DCT images and the periodicity of the corresponding 1D respiratory waveform (1DRW) used for phase binning in 4DCT reconstruction. Methods: Discrete Fourier transformation (DFT) was applied to analyze 1DRW periodicity. The breathing periodicity index (BPI) was defined as the sum of the largestmore » five Fourier coefficients, ranging from 0 to 1. Distortional motion artifacts (excluding blurring) of cine-scan 4DCT at the junctions of adjacent couch positions around the diaphragm were classified in three categories: incomplete, overlapping, and duplicate anatomies. To quantify these artifacts, discontinuity of the diaphragm at the junctions was measured in distance and averaged along six directions in three orthogonal views. Artifacts per junction (APJ) across the entire diaphragm were calculated in each breathing phase and phase-averaged APJ{sup ¯}, defined as motion-artifact severity (MAS), was obtained for each patient. To make MAS independent of patient-specific motion amplitude, two new MAS quantities were defined: MAS{sup D} is normalized to the maximum diaphragmatic displacement and MAS{sup V} is normalized to the mean diaphragmatic velocity (the breathing period was obtained from DFT analysis of 1DRW). Twenty-six patients’ free-breathing 4DCT images and corresponding 1DRW data were studied. Results: Higher APJ values were found around midventilation and full inhalation while the lowest APJ values were around full exhalation. The distribution of MAS is close to Poisson distribution with a mean of 2.2 mm. The BPI among the 26 patients was calculated with a value ranging from 0.25 to 0.93. The DFT calculation was within 3 s per 1DRW. Correlations were found between 1DRW periodicity and 4DCT artifact severity: −0.71 for MAS{sup D} and −0.73 for MAS{sup V}. A BPI greater than 0.85 in a 1DRW suggests minimal motion artifacts in the corresponding 4DCT images. Conclusions: The breathing periodicity index and motion-artifact severity index are introduced to assess the relationship between 1DRW and 4DCT. A correlation between 1DRW periodicity and 4DCT artifact severity has been established. The 1DRW periodicity provides a rapid means to estimate 4DCT image quality. The rapid 1DRW analysis and the correlative relationship can be applied prospectively to identify irregular breathers as candidates for breath coaching prior to 4DCT scan and retrospectively to select high-quality 4DCT images for clinical motion-management research.« less
Patel, Rajiv C; Baek, Jonggyu; Smith, Melinda A; Morgenstern, Lewis B; Lisabeth, Lynda D
2015-01-01
Objective Residential ethnic segregation may operate through multiple mechanisms to increase stroke risk. The current study evaluated if residential ethnic segregation was associated with stroke risk in a bi-ethnic population. Design Incident strokes were identified in Nueces County, Texas from 2000 to 2010. Residential ethnic segregation (range: 0–1) was derived for each census tract in the county (n=64) using 2000 U.S Census data, and categorized into: predominantly non-Hispanic white (NHW, <0.3); ethnically mixed (0.3–0.7); predominantly Mexican American (MA, >0.7). Multilevel Poisson regression models were fitted separately for NHWs and MAs to assess the association between residential ethnic segregation (predominantly NHW referent) and relative risk for stroke, adjusted for age category, sex and census tract-level median per capita income. Effect modification by age was also examined. Results In adjusted models, residential ethnic segregation was not associated with stroke risk in either ethnic group. Effect modification by age was significant in both groups. Young MAs and NHWs living in predominantly MA census tracts were at greater relative risk for stroke than those living in predominantly NHW census tracts, but this association was only significant for MAs [MAs: RR = 2.38 (95% CI: 1.31–4.31); NHWs: RR = 1.53 (95% CI: 0.92–2.52)]. Conclusion Our findings demonstrate that residential ethnic segregation may influence downstream stroke risk in young MAs. Pathways between residential ethnic segregation and stroke in young MAs should be explored. PMID:25812246
Digitization and Position Measurement of Astronomical Plates of Saturnian Satellites
NASA Astrophysics Data System (ADS)
Yan, D.; Yu, Y.; Zhang, H. Y.; Qiao, R. C.
2014-05-01
Using the advanced commercial scanners to digitize astronomical plates may be a simple and effective way. In this paper, we discuss the method of digitizing and astrometrically reducing six astronomical plates of Saturnian satellites, which were taken from the 1 m RCC (Ritchey Chretien Coude) telescope of Yunnan Observatory in 1988, by using the 10000XL scanner of Epson. The digitized images of the astronomical plates of Saturnian satellites are re-reduced, and the positions of Saturnian satellites based on the UCAC2 (The Second US Naval Observatory CCD Astrograph Catalog) catalogue are given. A comparison of our measured positions with the IMCCE (Institut de Mecanique Celeste et de Calcul des Ephemerides) ephemeris of Saturnian satellites shows the high quality of our measurements, which have an accuracy of 106 mas in right ascension and 89 mas in declination. Moreover, our measurements appear to be consistent with this ephemeris within only about 56 mas in right ascension and 9 mas in declination.
Sobre os sistemas de referência celeste
NASA Astrophysics Data System (ADS)
Poppe, P. C. R.; Martin, V. A. F.
2003-02-01
Apresentamos neste trabalho, algumas discussões sobre os sistemas de referência utilizados em Astronomia. Claramente, não é possível esgotar todo este assunto num único texto, mas esperamos, contudo, que o presente material possa ser apreciado nos cursos de Introdução à Astronomia, que estão cada vez mais presentes nas atuais propostas curriculares das graduações de Física. As discussões pertinentes às "Bases de Referência Celeste", serão apresentadas em um outro trabalho.
NASA Astrophysics Data System (ADS)
Lindegren, Lennart
2012-01-01
The launch of the Hipparcos satellite in 1989 and the Hubble Space Telescope in 1990 revolutionized astrometry. By no means does this imply that not much progress was made in the ground-based techniques used exclusively until then. On the contrary, the 1960s to 1980s saw an intense development of new or highly improved instruments, including photoelectric meridian circles, automated plate measuring machines, and the use of chargecoupled device (CCD) detectors for small-field differential astrometry (for a review of optical astrometry at the time, see Monet 1988). In the radio domain, very long baseline interferometry (VLBI) astrometry already provided an extragalactic reference frame accurate to about 1 milliarcsecond (mas) (Ma et al. 1990). Spectacular improvements were made in terms of accuracy, the faintness of the observed objects, and their numbers. However, there was a widening gulf between small-angle astrometry, where differential techniques could overcome atmospheric effects down to below 1 mas, and large-angle astrometry, where conventional instruments such as meridian circles seemed to have hit a barrier in the underlying systematic errors at about 100 mas. Though very precise, the small-angle measurements were of limited use for the determination of positions and proper motions, due to the lack of suitable reference objects in the small fields, and even for parallaxes the necessary correction for the mean parallax of background stars was highly non-trivial. Linking the optical observations to the accurate VLBI frame also proved extremely difficult.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elzibak, A; Safigholi, H; Soliman, A
2015-06-15
Purpose: To examine CT metal image artifact from a novel direction-modulated brachytherapy (DMBT) tandem applicator (95% tungsten) for cervical cancer using a commercially available orthopedic metal artifact reduction (O-MAR) algorithm. Comparison to a conventional stainless steel applicator is also performed. Methods: Each applicator was placed in a water-filled phantom resembling the female pelvis and scanned in a Philips Brilliance 16-slice CT scanner using two pelvis protocols: a typical clinical protocol (120kVp, 16×0.75mm collimation, 0.692 pitch, 1.0s rotation, 350mm field of view (FOV), 600mAs, 1.5mm slices) and a protocol with a higher kVp and mAs setting useful for larger patients (140kVp,more » 16×0.75mm collimation, 0.688 pitch, 1.5s rotation, 350mm FOV, 870mAs, 1.5mm slices). Images of each tandem were acquired with and without the application of the O-MAR algorithm. Baseline scans of the phantom (no applicator) were also collected. CT numbers were quantified at distances from 5 to 30 mm away from the applicator’s edge (in increments of 5mm) using measurements at eight angles around the applicator, on three consecutive slices. Results: While the presence of both applicators degraded image quality, the DMBT applicator resulted in larger streaking artifacts and dark areas in the image compared to the stainless steel applicator. Application of the O-MAR algorithm improved all acquired images, both visually and quantitatively. The use of low and high kVp and mAs settings (120 kVp/600mAs and 140 kVp/870mAs) in conjunction with the O-MAR algorithm lead to similar CT numbers in the vicinity of the applicator and a similar reduction of the induced metal artifact. Conclusion: This work indicated that metal artifacts induced by the DMBT and the stainless steel applicator are greatly reduced when using the O-MAR algorithm, leading to better quality phantom images. The use of a high dose protocol provided similar improvements in metal artifacts compared to the clinical protocol.« less
Satellite and airborne IR sensor validation by an airborne interferometer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gumley, L.E.; Delst, P.F. van; Moeller, C.C.
1996-11-01
The validation of in-orbit longwave IR radiances from the GOES-8 Sounder and inflight longwave IR radiances from the MODIS Airborne Simulator (MAS) is described. The reference used is the airborne University of Wisconsin High Resolution Interferometer Sounder (HIS). The calibration of each sensor is described. Data collected during the Ocean Temperature Interferometric Survey (OTIS) experiment in January 1995 is used in the comparison between sensors. Detailed forward calculations of at-sensor radiance are used to account for the difference in GOES-8 and HIS altitude and viewing geometry. MAS radiances and spectrally averaged HIS radiances are compared directly. Differences between GOES-8 andmore » HIS brightness temperatures, and GOES-8 and MAS brightness temperatures, are found to be with 1.0 K for the majority of longwave channels examined. The same validation approach will be used for future sensors such as the Moderate Resolution Imaging Spectroradiometer (MODIS) and the Atmospheric Infrared Sounder (AIRS). 11 refs., 2 figs., 4 tabs.« less
Second Epoch VLBA Calibrator Survey Observations - VCS-II
NASA Technical Reports Server (NTRS)
Gordon, David; Jacobs, Christopher; Beasley, Anthony; Peck, Alison; Gaume, Ralph; Charlot, Patrick; Fey, Alan; Ma, Chopo; Titov, Oleg; Boboltz, David
2016-01-01
Six very successful VLBA calibrator survey campaigns were run between 1994 and 2007 to build up a large list of compact radio sources with positions precise enough for use as VLBI phase reference calibrators. We report on the results of a second epoch VLBA Calibrator Survey campaign (VCS-II) in which 2400 VCS sources were re-observed at X and S bands in order to improve the upcoming third realization of the International Celestial Reference Frame (ICRF3) as well as to improve their usefulness as VLBI phase reference calibrators. In this survey, some 2062 previously detected sources and 324 previously undetected sources were detected and revised positions are presented. Average position uncertainties for the reobserved sources were reduced from 1.14 and 1.98 mas to 0.24 and 0.41 mas in RA and Declination, respectively, or by nearly a factor of 5. Minimum detected flux values were approximately 15 and 28 mJy in X and S bands, respectively, and median total fluxes are approximately 230 and 280 mJy. The vast majority of these sources are flat-spectrum sources, with approximately 82% having spectral indices greater than -0.5.
Second Epoch VLBA Calibrator Survey Observations: VCS-II
NASA Astrophysics Data System (ADS)
Gordon, David; Jacobs, Christopher; Beasley, Anthony; Peck, Alison; Gaume, Ralph; Charlot, Patrick; Fey, Alan; Ma, Chopo; Titov, Oleg; Boboltz, David
2016-06-01
Six very successful Very Long Baseline Array (VLBA) calibrator survey campaigns were run between 1994 and 2007 to build up a large list of compact radio sources with positions precise enough for use as very long baseline interferometry (VLBI) phase reference calibrators. We report on the results of a second epoch VLBA Calibrator Survey campaign (VCS-II) in which 2400 VCS sources were re-observed in the X and S bands in order to improve the upcoming third realization of the International Celestial Reference Frame (ICRF3) as well as to improve their usefulness as VLBI phase reference calibrators. In this survey, some 2062 previously detected sources and 324 previously undetected sources were detected and revised positions are presented. Average position uncertainties for the re-observed sources were reduced from 1.14 and 1.98 mas to 0.24 and 0.41 mas in R.A. and decl., respectively, or by nearly a factor of 5. Minimum detected flux values were approximately 15 and 28 mJy in the X and S bands, respectively, and median total fluxes are approximately 230 and 280 mJy. The vast majority of these sources are flat-spectrum sources, with ˜82% having spectral indices greater than -0.5.
NASA Astrophysics Data System (ADS)
Asilah Khairi, Nor; Bahari Jambek, Asral
2017-11-01
An Internet of Things (IoT) device is usually powered by a small battery, which does not last long. As a result, saving energy in IoT devices has become an important issue when it comes to this subject. Since power consumption is the primary cause of radio communication, some researchers have proposed several compression algorithms with the purpose of overcoming this particular problem. Several data compression algorithms from previous reference papers are discussed in this paper. The description of the compression algorithm in the reference papers was collected and summarized in a table form. From the analysis, MAS compression algorithm was selected as a project prototype due to its high potential for meeting the project requirements. Besides that, it also produced better performance regarding energy-saving, better memory usage, and data transmission efficiency. This method is also suitable to be implemented in WSN. MAS compression algorithm will be prototyped and applied in portable electronic devices for Internet of Things applications.
NASA Astrophysics Data System (ADS)
Hassan, G. M.; Rabie, N.; Mustafa, K. A.; Abdel-Khalik, S. S.
2012-09-01
Radiation exposure and image quality in X-ray diagnostic radiology provide a clear understanding of the relationship between the radiation dose delivered to a patient and image quality in optimizing medical diagnostic radiology. Because a certain amount of radiation is unavoidably delivered to patients, this should be as low as reasonably achievable. Several X-ray diagnostic machines were used at different medical diagnostic centers in Egypt for studying the beam quality and the dose delivered to the patient. This article studies the factors affecting the beam quality, such as the kilo-volt peak (kVp), exposure time (mSc), tube current (mAs) and the absorbed dose in (μGy) for different examinations. The maximum absorbed dose measured per mAs was 594±239 and 12.5±3.7 μGy for the abdomen and the chest, respectively, while the absorbed dose at the elbow was 18±6 μGy, which was the minimum dose recorded. The compound and expanded uncertainties accompanying these measurements were 4±0.35% and 8±0.7%, respectively. The measurements were done through quality control tests as acceptance procedures.
NASA Astrophysics Data System (ADS)
Jeon, Pil-Hyun; Kim, Hee-Joung; Lee, Chang-Lae; Kim, Dae-Hong; Lee, Won-Hyung; Jeon, Sung-Su
2012-06-01
For a considerable number of emergency computed tomography (CT) scans, patients are unable to position their arms above their head due to traumatic injuries. The arms-down position has been shown to reduce image quality with beam-hardening artifacts in the dorsal regions of the liver, spleen, and kidneys, rendering these images non-diagnostic. The purpose of this study was to evaluate the effect of arm position on the image quality in patients undergoing whole-body CT. We acquired CT scans with various acquisition parameters at voltages of 80, 120, and 140 kVp and an increasing tube current from 200 to 400 mAs in 50 mAs increments. The image noise and the contrast assessment were considered for quantitative analyses of the CT images. The image noise (IN), the contrast-to-noise ratio (CNR), the signal-to-noise ratio (SNR), and the coefficient of variation (COV) were evaluated. Quantitative analyses of the experiments were performed with CT scans representative of five different arm positions. Results of the CT scans acquired at 120 kVp and 250 mAs showed high image quality in patients with both arms raised above the head (SNR: 12.4, CNR: 10.9, and COV: 8.1) and both arms flexed at the elbows on the chest (SNR: 11.5, CNR: 10.2, and COV: 8.8) while the image quality significantly decreased with both arms in the down position (SNR: 9.1, CNR: 7.6, and COV: 11). Both arms raised, one arm raised, and both arms flexed improved the image quality compared to arms in the down position by reducing beam-hardening and streak artifacts caused by the arms being at the side of body. This study provides optimal methods for achieving higher image quality and lower noise in abdominal CT for trauma patients.
Stress Echocardiography for the Diagnosis of Coronary Artery Disease
2010-01-01
Executive Summary In July 2009, the Medical Advisory Secretariat (MAS) began work on Non-Invasive Cardiac Imaging Technologies for the Diagnosis of Coronary Artery Disease (CAD), an evidence-based review of the literature surrounding different cardiac imaging modalities to ensure that appropriate technologies are accessed by patients suspected of having CAD. This project came about when the Health Services Branch at the Ministry of Health and Long-Term Care asked MAS to provide an evidentiary platform on effectiveness and cost-effectiveness of non-invasive cardiac imaging modalities. After an initial review of the strategy and consultation with experts, MAS identified five key non-invasive cardiac imaging technologies for the diagnosis of CAD. Evidence-based analyses have been prepared for each of these five imaging modalities: cardiac magnetic resonance imaging, single photon emission computed tomography, 64-slice computed tomographic angiography, stress echocardiography, and stress echocardiography with contrast. For each technology, an economic analysis was also completed (where appropriate). A summary decision analytic model was then developed to encapsulate the data from each of these reports (available on the OHTAC and MAS website). The Non-Invasive Cardiac Imaging Technologies for the Diagnosis of Coronary Artery Disease series is made up of the following reports, which can be publicly accessed at the MAS website at: www.health.gov.on.ca/mas"> www.health.gov.on.ca/mas or at www.health.gov.on.ca/english/providers/program/mas/mas_about.html Single Photon Emission Computed Tomography for the Diagnosis of Coronary Artery Disease: An Evidence-Based Analysis Stress Echocardiography for the Diagnosis of Coronary Artery Disease: An Evidence-Based Analysis Stress Echocardiography with Contrast for the Diagnosis of Coronary Artery Disease: An Evidence-Based Analysis 64-Slice Computed Tomographic Angiography for the Diagnosis of Coronary Artery Disease: An Evidence-Based Analysis Cardiac Magnetic Resonance Imaging for the Diagnosis of Coronary Artery Disease: An Evidence-Based Analysis Pease note that two related evidence-based analyses of non-invasive cardiac imaging technologies for the assessment of myocardial viability are also available on the MAS website: Positron Emission Tomography for the Assessment of Myocardial Viability: An Evidence-Based Analysis Magnetic Resonance Imaging for the Assessment of Myocardial Viability: an Evidence-Based Analysis The Toronto Health Economics and Technology Assessment Collaborative has also produced an associated economic report entitled: The Relative Cost-effectiveness of Five Non-invasive Cardiac Imaging Technologies for Diagnosing Coronary Artery Disease in Ontario [Internet]. Available from: http://theta.utoronto.ca/reports/?id=7 Objective The objective of the analysis is to determine the diagnostic accuracy of stress echocardiography (ECHO) in the diagnosis of patients with suspected coronary artery disease (CAD) compared to coronary angiography (CA). Stress Echocardiography Stress ECHO is a non-invasive technology that images the heart using ultrasound. It is one of the most commonly employed imaging techniques for investigating a variety of cardiac abnormalities in both community and hospital settings. A complete ECHO exam includes M-mode, 2-dimensional (2-D) images and Doppler imaging. In order to diagnosis CAD and assess whether myocardial ischemia is present, images obtained at rest are compared to those obtained during or immediately after stress. The most commonly used agents used to induce stress are exercise and pharmacological agents such as dobutamine and dipyridamole. The hallmark of stress-induced myocardial ischemia is worsening of wall motion abnormalities or the development of new wall motion abnormalities. A major challenge for stress ECHO is that the interpretation of wall motion contractility and function is subjective. This leads to inter-observer variability and reduced reproducibility. Further, it is estimated that approximately 30% of patients have sub-optimal stress ECHO exams. To overcome this limitation, contrast agents for LV opacification have been developed. Although stress ECHO is a relatively easy to use technology that poses only a low risk of adverse events compared to other imaging technologies, it may potentially be overused and/or misused in CAD diagnosis. Several recent advances have been made focusing on quantitative methods for assessment, improved image quality and enhanced portability, however, evidence on the effectiveness and clinical utility of these enhancements is limited. Evidence-Based Analysis Research Questions What is the diagnostic accuracy of stress ECHO for the diagnosis of patients with suspected CAD compared to the reference standard of CA? What is the clinical utility1 of stress ECHO? Literature Search A literature search was performed on August 28, 2009 using OVID MEDLINE, MEDLINE In-Process and Other Non-Indexed Citations, EMBASE, the Cumulative Index to Nursing & Allied Health Literature (CINAHL), the Cochrane Library, and the International Agency for Health Technology Assessment (INAHTA) for studies published from January 1, 2004 until August 21, 2009. Abstracts were reviewed by a single reviewer and, for those studies meeting the eligibility criteria, full-text articles were obtained. Reference lists were also examined for any relevant studies not identified through the search. Inclusion Criteria Systematic reviews, meta-analyses, randomized controlled trials, prospective observational studies, retrospective analyses Minimum sample size of 20 enrolled patients Comparison to CA (reference standard) Definition of CAD specified as either ≥50%, ≥70% or ≥75% coronary artery stenosis on CA Reporting accuracy data on individual patients (rather than accuracy data stratified by segments of the heart) English Human Exclusion Criteria Duplicate studies Non-systematic reviews, case reports Grey literature (e.g., conference abstracts) Insufficient data for independent calculation of sensitivity and specificity Use of ECHO for purposes other than diagnosis of CAD (e.g., arrhythmia, valvular disease, mitral stenosis, pre-operative risk of MI) Transesophageal ECHO since its primary use is for non-CAD indications such as endocarditis, intracardiac thrombi, valvular disorders Only resting ECHO performed Outcomes of Interest Accuracy outcomes (sensitivity, specificity, positive predictive value, negative predictive value) Costs Summary of Findings Given the vast amount of published literature on stress ECHO, it was decided to focus on the studies contained in the comprehensive 2007 review by Heijenbrok-Kal et al. (1) as a basis for the MAS evidence-based analysis. In applying our inclusion and exclusion criteria, 105 observational studies containing information on 13,035 patients were included. Six studies examined stress ECHO with adenosine, 26 with dipyridamole and 77 with dobutamine, the latter being the most commonly used pharmacological stress ECHO agent in Ontario. A further 18 studies employed exercise as the stressor.2 The prevalence of CAD ranged from 19% to 94% with a mean estimated prevalence of 70%. Based on the results of these studies the following conclusions were made: Based on the available evidence, stress ECHO is a useful imaging modality for the diagnosis of CAD in patients with suspected disease. The overall pooled sensitivity is 0.80 (95% CI: 0.77 – 0.82) and the pooled specificity is 0.84 (95% CI: 0.82 – 0.87) using CA as the reference standard. The AUC derived from the sROC curve is 0.895 and the DOR is 20.64. For pharmacological stress, the pooled sensitivity is 0.79 (95% CI: 0.71 – 0.87) and the pooled specificity is 0.85 (95% CI: 0.83 – 0.88). When exercise is employed as the stress agent, the pooled sensitivity is 0.81 (95% CI: 0.76– 0.86) and the pooled specificity is 0.79 (95% CI: 0.71 – 0.87). Although pharmacological stress and exercise stress would be indicated for different patient populations based on ability to exercise there were no significant differences in sensitivity and specificity. Based on clinical experts, diagnostic accuracy on stress ECHO depends on the patient population, the expertise of the interpreter and the quality of the image. PMID:23074412
Stress echocardiography for the diagnosis of coronary artery disease: an evidence-based analysis.
2010-01-01
In July 2009, the Medical Advisory Secretariat (MAS) began work on Non-Invasive Cardiac Imaging Technologies for the Diagnosis of Coronary Artery Disease (CAD), an evidence-based review of the literature surrounding different cardiac imaging modalities to ensure that appropriate technologies are accessed by patients suspected of having CAD. This project came about when the Health Services Branch at the Ministry of Health and Long-Term Care asked MAS to provide an evidentiary platform on effectiveness and cost-effectiveness of non-invasive cardiac imaging modalities.After an initial review of the strategy and consultation with experts, MAS identified five key non-invasive cardiac imaging technologies for the diagnosis of CAD. Evidence-based analyses have been prepared for each of these five imaging modalities: cardiac magnetic resonance imaging, single photon emission computed tomography, 64-slice computed tomographic angiography, stress echocardiography, and stress echocardiography with contrast. For each technology, an economic analysis was also completed (where appropriate). A summary decision analytic model was then developed to encapsulate the data from each of these reports (available on the OHTAC and MAS website).The Non-Invasive Cardiac Imaging Technologies for the Diagnosis of Coronary Artery Disease series is made up of the following reports, which can be publicly accessed at the MAS website at: www.health.gov.on.ca/mas">www.health.gov.on.ca/mas or at www.health.gov.on.ca/english/providers/program/mas/mas_about.htmlSINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY FOR THE DIAGNOSIS OF CORONARY ARTERY DISEASE: An Evidence-Based AnalysisSTRESS ECHOCARDIOGRAPHY FOR THE DIAGNOSIS OF CORONARY ARTERY DISEASE: An Evidence-Based AnalysisSTRESS ECHOCARDIOGRAPHY WITH CONTRAST FOR THE DIAGNOSIS OF CORONARY ARTERY DISEASE: An Evidence-Based Analysis64-Slice Computed Tomographic Angiography for the Diagnosis of Coronary Artery Disease: An Evidence-Based AnalysisCARDIAC MAGNETIC RESONANCE IMAGING FOR THE DIAGNOSIS OF CORONARY ARTERY DISEASE: An Evidence-Based AnalysisPease note that two related evidence-based analyses of non-invasive cardiac imaging technologies for the assessment of myocardial viability are also available on the MAS website:POSITRON EMISSION TOMOGRAPHY FOR THE ASSESSMENT OF MYOCARDIAL VIABILITY: An Evidence-Based AnalysisMAGNETIC RESONANCE IMAGING FOR THE ASSESSMENT OF MYOCARDIAL VIABILITY: an Evidence-Based AnalysisThe Toronto Health Economics and Technology Assessment Collaborative has also produced an associated economic report entitled:The Relative Cost-effectiveness of Five Non-invasive Cardiac Imaging Technologies for Diagnosing Coronary Artery Disease in Ontario [Internet]. Available from: http://theta.utoronto.ca/reports/?id=7 OBJECTIVE: The objective of the analysis is to determine the diagnostic accuracy of stress echocardiography (ECHO) in the diagnosis of patients with suspected coronary artery disease (CAD) compared to coronary angiography (CA). STRESS ECHOCARDIOGRAPHY: Stress ECHO is a non-invasive technology that images the heart using ultrasound. It is one of the most commonly employed imaging techniques for investigating a variety of cardiac abnormalities in both community and hospital settings. A complete ECHO exam includes M-mode, 2-dimensional (2-D) images and Doppler imaging. In order to diagnosis CAD and assess whether myocardial ischemia is present, images obtained at rest are compared to those obtained during or immediately after stress. The most commonly used agents used to induce stress are exercise and pharmacological agents such as dobutamine and dipyridamole. The hallmark of stress-induced myocardial ischemia is worsening of wall motion abnormalities or the development of new wall motion abnormalities. A major challenge for stress ECHO is that the interpretation of wall motion contractility and function is subjective. This leads to inter-observer variability and reduced reproducibility. Further, it is estimated that approximately 30% of patients have sub-optimal stress ECHO exams. To overcome this limitation, contrast agents for LV opacification have been developed. Although stress ECHO is a relatively easy to use technology that poses only a low risk of adverse events compared to other imaging technologies, it may potentially be overused and/or misused in CAD diagnosis. Several recent advances have been made focusing on quantitative methods for assessment, improved image quality and enhanced portability, however, evidence on the effectiveness and clinical utility of these enhancements is limited. EVIDENCE-BASED ANALYSIS: What is the diagnostic accuracy of stress ECHO for the diagnosis of patients with suspected CAD compared to the reference standard of CA?What is the clinical utility() of stress ECHO? A literature search was performed on August 28, 2009 using OVID MEDLINE, MEDLINE In-Process and Other Non-Indexed Citations, EMBASE, the Cumulative Index to Nursing & Allied Health Literature (CINAHL), the Cochrane Library, and the International Agency for Health Technology Assessment (INAHTA) for studies published from January 1, 2004 until August 21, 2009. Abstracts were reviewed by a single reviewer and, for those studies meeting the eligibility criteria, full-text articles were obtained. Reference lists were also examined for any relevant studies not identified through the search. Systematic reviews, meta-analyses, randomized controlled trials, prospective observational studies, retrospective analysesMinimum sample size of 20 enrolled patientsComparison to CA (reference standard)Definition of CAD specified as either ≥50%, ≥70% or ≥75% coronary artery stenosis on CAReporting accuracy data on individual patients (rather than accuracy data stratified by segments of the heart)EnglishHuman Duplicate studiesNon-systematic reviews, case reportsGrey literature (e.g., conference abstracts)Insufficient data for independent calculation of sensitivity and specificityUse of ECHO for purposes other than diagnosis of CAD (e.g., arrhythmia, valvular disease, mitral stenosis, pre-operative risk of MI)Transesophageal ECHO since its primary use is for non-CAD indications such as endocarditis, intracardiac thrombi, valvular disordersOnly resting ECHO performed Accuracy outcomes (sensitivity, specificity, positive predictive value, negative predictive value)Costs Given the vast amount of published literature on stress ECHO, it was decided to focus on the studies contained in the comprehensive 2007 review by Heijenbrok-Kal et al. (1) as a basis for the MAS evidence-based analysis. In applying our inclusion and exclusion criteria, 105 observational studies containing information on 13,035 patients were included. Six studies examined stress ECHO with adenosine, 26 with dipyridamole and 77 with dobutamine, the latter being the most commonly used pharmacological stress ECHO agent in Ontario. A further 18 studies employed exercise as the stressor.() The prevalence of CAD ranged from 19% to 94% with a mean estimated prevalence of 70%. Based on the results of these studies the following conclusions were made: Based on the available evidence, stress ECHO is a useful imaging modality for the diagnosis of CAD in patients with suspected disease. The overall pooled sensitivity is 0.80 (95% CI: 0.77 - 0.82) and the pooled specificity is 0.84 (95% CI: 0.82 - 0.87) using CA as the reference standard. The AUC derived from the sROC curve is 0.895 and the DOR is 20.64.For pharmacological stress, the pooled sensitivity is 0.79 (95% CI: 0.71 - 0.87) and the pooled specificity is 0.85 (95% CI: 0.83 - 0.88). When exercise is employed as the stress agent, the pooled sensitivity is 0.81 (95% CI: 0.76- 0.86) and the pooled specificity is 0.79 (95% CI: 0.71 - 0.87). Although pharmacological stress and exercise stress would be indicated for different patient populations based on ability to exercise there were no significant differences in sensitivity and specificity.Based on clinical experts, diagnostic accuracy on stress ECHO depends on the patient population, the expertise of the interpreter and the quality of the image.
Ma, Pei-Luen; Jheng, Yan-Wun; Jheng, Bi-Wei; Hou, I-Ching
2017-01-01
Bar code medication administration (BCMA) could reduce medical errors and promote patient safety. This research uses modified information systems success model (M-ISS model) to evaluate nurses' acceptance to BCMA. The result showed moderate correlation between medication administration safety (MAS) to system quality, information quality, service quality, user satisfaction, and limited satisfaction.
The first US Naval Observatory CCD Astrograph Catalog
NASA Astrophysics Data System (ADS)
Germain, M. E.; Zacharias, N.; Urban, S. E.; Rafferty, T. J.; Holdenried, E. R.; Zacharias, M. I.; Hall, D. M.; Wycoff, G. L.; Monet, D. G.
2000-05-01
The USNO CCD Astrograph Catalog (UCAC) project is a high precision, astrometric survey of stars having R magnitudes between 7th and 16th. The positional accuracy is 20 mas for stars between 9th and 14th, and 70 mas for fainter stars. This gives a density (stars per square degree) higher than that of the Guide Star Catalog (GSC), with an improvement in positional accuracy of about a factor of ten. Observations began in January 1998 at Cerro Tololo Inter--American Observatory (CTIO) using a five-element 0.2 meter astrograph equipped with a 4k by 4k CCD. The instrument will be moved north in early 2001, and full sky coverage is expected by early 2003. A preliminary catalog (UCAC1) of positions and proper motions of 27 million stars has been constructed which is available on CD-ROM from USNO. Observations between 13 Feb 1998 and 07 Nov 1999 are included with a total of over 79,000 CCD frames covering 80% of the Southern Hemisphere. The catalog is on the International Celestial Reference System (ICRS), which is consistent with J2000. Proper motions of bright stars (V <= 12.5) were derived using a combination of ground-based astrometric catalogs, Hipparcos, and Tycho-2 positions, giving a typical error of 3 mas/yr. For the fainter stars the USNO A2.0 (Monet, 1998) was used as first epoch, with typical proper motion errors of 10 to 15 mas/yr. External comparisons with Tycho-2 and the Yale Southern Proper Motion (SPM) 2.0 data reveal systematic errors to be only on the 10 mas level.
Zhang, Juxia; Wang, Jiancheng; Han, Lin; Zhang, Fengwa; Cao, Jianxun; Ma, Yuxia
2015-01-01
Systematic reviews (SRs) and meta-analyses (MAs) of nursing interventions have become increasingly popular in China. This review provides the first examination of epidemiological characteristics of these SRs as well as compliance with the Preferred Reporting Items for Systematic Reviews and Meta-analyses and Assessment of Multiple Systematic Reviews guidelines. The purpose of this study was to examine epidemiologic and reporting characteristics as well as the methodologic quality of SRs and MAs of nursing interventions published in Chinese journals. Four Chinese databases were searched (the Chinese Biomedicine Literature Database, Chinese Scientific Journal Full-text Database, Chinese Journal Full-text Database, and Wanfang Database) for SRs and MAs of nursing intervention from inception through June 2013. Data were extracted into Excel (Microsoft, Redmond, WA). The Assessment of Multiple Systematic Reviews and Preferred Reporting Items for Systematic Reviews and Meta-analyses checklists were used to assess methodologic quality and reporting characteristics, respectively. A total of 144 SRs were identified, most (97.2%) of which used "systematic review" or "meta-analyses" in the titles. None of the reviews had been updated. Nearly half (41%) were written by nurses, and more than half (61%) were reported in specialist journals. The most common conditions studied were endocrine, nutritional and metabolic diseases, and neoplasms. Most (70.8%) reported information about quality assessment, whereas less than half (25%) reported assessing for publication bias. None of the reviews reported a conflict of interest. Although many SRs of nursing interventions have been published in Chinese journals, the quality of these reviews is of concern. As a potential key source of information for nurses and nursing administrators, not only were many of these reviews incomplete in the information they provided, but also some results were misleading. Improving the quality of SRs of nursing interventions conducted and published by nurses in China is urgently needed in order to increase the value of these studies. Copyright © 2015 Elsevier Inc. All rights reserved.
USDA-ARS?s Scientific Manuscript database
Marker-assisted selection (MAS) in stone fruit (Prunus species) breeding is currently difficult to achieve due to the polygenic nature of themost relevant agronomic traits linked to fruit quality. Genotyping by sequencing (GBS), however, provides a large quantity of useful data suitable for finemapp...
Transcranial magnetic stimulation primes the effects of exercise therapy in multiple sclerosis.
Mori, Francesco; Ljoka, Concetta; Magni, Elisabetta; Codecà, Claudia; Kusayanagi, Hajime; Monteleone, Fabrizia; Sancesario, Andrea; Bernardi, Giorgio; Koch, Giacomo; Foti, Calogero; Centonze, Diego
2011-07-01
Exercise therapy (ET) can be beneficial in disabled multiple sclerosis (MS) patients. Intermittent transcranial magnetic theta burst stimulation (iTBS) induces long-term excitability changes of the cerebral cortex and may ameliorate spasticity in MS. We investigated whether the combination of iTBS and a program of ET can improve motor disability in MS patients. In a double-blind, sham-controlled trial, 30 participants were randomized to three different interventions: iTBS plus ET, sham stimulation plus ET, and iTBS alone. Before and after 2 weeks of treatment, measures of spasticity through the modified Ashworth scale (MAS) and the 88 items Multiple Sclerosis Spasticity Score questionnaire (MSSS-88), fatigue through the Fatigue Severity Scale (FSS), daily living activities (ADL) through the Barthel index and health-related quality of life (HRQoL) through the 54 items Multiple Sclerosis Quality of life inventory (MSQoL-54) were collected. iTBS plus ET reduced MAS, MSSS-88, FSS scores, while in the Barthel index and MSQoL-54, physical composite scores were increased. iTBS alone caused a reduction of the MAS score, while none of the measured scales showed significant changes after sham iTBS plus ET. iTBS associated with ET is a promising tool for motor rehabilitation of MS patients.
In vitro comparison of endplate preparation between four mini-open interbody fusion approaches.
Tatsumi, Robert; Lee, Yu-Po; Khajavi, Kaveh; Taylor, William; Chen, Foster; Bae, Hyun
2015-04-01
Discectomy and endplate preparation are important steps in interbody fusion for ensuring sufficient arthrodesis. While modern less-invasive approaches for lumbar interbody fusion have gained in popularity, concerns exist regarding their ability to allow for adequate disc space and endplate preparation. Thus, the purpose of this study was to quantitatively and qualitatively evaluate and compare disc space and endplate preparation achieved with four less-invasive approaches for lumbar interbody fusion in cadaveric spines. A total of 24 disc spaces (48 endplates) from L2 to L5 were prepared in eight cadaveric torsos using mini-open anterior lumbar interbody fusion (mini-ALIF), minimally invasive posterior lumbar interbody fusion (MAS PLIF), minimally invasive transforaminal lumbar interbody fusion (MAS TLIF) or minimally invasive lateral, transpsoas interbody fusion (XLIF) on two specimens each, for a total of six levels and 12 endplates prepared per procedure type. Following complete discectomy and endplate preparation, spines were excised and split axially at the interbody disc spaces. Endplates were digitally photographed and evaluated using image analysis software. Area of endplate preparation was measured and qualitative evaluation was also performed to grade the quality of preparation. The XLIF approach resulted in the greatest relative area of endplate preparation (58.3 %) while mini-ALIF resulted in the lowest at 35.0 %. Overall, there were no differences in percentage of preparation between cranial and caudal endplates, though this was significantly different in the XLIF group (65 vs 52 %, respectively). ALL damage was observed in 3 MAS TLIF levels. Percentage of endplate that was deemed to have complete disc removal was highest in XLIF group with 90 % compared to 65 % in MAS TLIF group, 43 % in MAS PLIF, and 40 % in mini-ALIF group. Endplate damage area was highest in the MAS TLIF group at 48 % and lowest in XLIF group at 4 %. These results demonstrate that adequate endplate preparation for interbody fusion can be achieved utilizing various minimally invasive approach techniques (mini-ALIF, MAS TLIF, MAS PLIF, XLIF), however, XLIF appears to provide a greater area of and more complete endplate preparation.
Jurd, Andrew P S; Titman, Jeremy J
2009-08-28
Solid-state NMR experiments can be used to determine conformational parameters, such as interatomic distances and torsion angles. The latter can be obtained from measurements of the relative orientation of two chemical shift tensors, if the orientation of these with respect to the surrounding bonds is known. In this paper, a new rotor-synchronized magic angle spinning (MAS) dipolar correlation experiment is described which can be used in this way. Because the experiment requires slow MAS rates, a novel recoupling sequence, designed using symmetry principles, is incorporated into the mixing period. This recoupling sequence is based in turn on a new composite cyclic pulse referred to as COAST (for combined offset and anisotropy stabilization). The new COAST-C7(2)(1) sequence is shown to give good theoretical and experimental recoupling efficiency, even when the CSA far exceeds the MAS rate. In this regime, previous recoupling sequences, such as POST-C7(2)(1), exhibit poor recoupling performance. The effectiveness of the new method has been explored by a study of the dipeptide L-phenylalanyl-L-phenylalanine.
NASA Astrophysics Data System (ADS)
Martin, Olivier A.; Correia, Carlos M.; Gendron, Eric; Rousset, Gerard; Gratadour, Damien; Vidal, Fabrice; Morris, Tim J.; Basden, Alastair G.; Myers, Richard M.; Neichel, Benoit; Fusco, Thierry
2016-10-01
In preparation of future multiobject spectrographs (MOS) whose one of the major role is to provide an extensive statistical studies of high redshifted galaxies surveyed, the demonstrator CANARY has been designed to tackle technical challenges related to open-loop adaptive optics (AO) control with jointed Natural Guide Star and Laser Guide Star tomography. We have developed a point spread function (PSF) reconstruction algorithm dedicated to multiobject adaptive optics systems using system telemetry to estimate the PSF potentially anywhere in the observed field, a prerequisite to postprocess AO-corrected observations in integral field spectroscopy. We show how to handle off-axis data to estimate the PSF using atmospheric tomography and compare it to a classical approach that uses on-axis residual phase from a truth sensor observing a natural bright source. We have reconstructed over 450 on-sky CANARY PSFs and we get bias/1-σ standard-deviation (std) of 1.3/4.8 on the H-band Strehl ratio (SR) with 92.3% of correlation between reconstructed and sky SR. On the full-width at half-maximum, we get, respectively, 2.94 mas, 19.9 mas, and 88.3% for the bias, std, and correlation. The reference method achieves 0.4/3.5/95% on the SR and 2.71 mas/14.9 mas/92.5% on the FWHM for the bias/std/correlation.
Patient's experience of treatment for sleep apnoea with a mandibular advancement splint.
Bhamrah, Gurprit; Dhir, Arti; Cash, Alex; Ahmad, Sofia; Winchester, Lindsay J
2015-10-01
Obstructive sleep apnoea (OSA) is a well recognised clinical disorder in which there is narrowing and repeated collapse of the upper airway during sleep resulting in the cessation of breathing. Patients with mild to moderate sleep apnoea are often provided with mandibular advancement splint (MAS) therapy as a form of first line or definitive treatment. The aims of this audit were to evaluate patient satisfaction and success of MAS therapy. 93 patients diagnosed with sleep apnoea and suitable for a splint were recruited prospectively at Queen Victoria Hospital, East Grinstead between January 2009 and October 2010. A patient satisfaction questionnaire was developed by health professionals involved in the care of patients with sleep apnoea and assessed for face and content validity and reliability. Participants completed the questionnaire six weeks after the splint was fitted. 44% who previously experienced snoring now reported no snoring and 47% reported less snoring since wearing the MAS appliance. 69% reported complete resolution of sleep apnoea symptoms. 37% experienced aching teeth and 33% experienced having a dry throat when wearing the appliance. 86% of sleeping partners felt that their quality of sleep was improved following their partners treatment. The standards set for each criteria in this audit were met. MAS treatment has a key role to play in the management of obstructive sleep apnoea with high rates of patient satisfaction and the majority of patients partners reporting a significant improvement in their own and their partners sleep quality. Copyright © 2014 Royal College of Surgeons of Edinburgh (Scottish charity number SC005317) and Royal College of Surgeons in Ireland. Published by Elsevier Ltd. All rights reserved.
Gomez-Cardona, Daniel; Li, Ke; Hsieh, Jiang; Lubner, Meghan G.; Pickhardt, Perry J.; Chen, Guang-Hong
2016-01-01
Purpose: Phantom-based objective image quality assessment methods are widely used in the medical physics community. For a filtered backprojection (FBP) reconstruction-based linear or quasilinear imaging system, the use of this methodology is well justified. Many key image quality metrics acquired with phantom studies can be directly applied to in vivo human subject studies. Recently, a variety of image quality metrics have been investigated for model-based iterative image reconstruction (MBIR) methods and several novel characteristics have been discovered in phantom studies. However, the following question remains unanswered: can certain results obtained from phantom studies be generalized to in vivo animal studies and human subject studies? The purpose of this paper is to address this question. Methods: One of the most striking results obtained from phantom studies is a novel power-law relationship between noise variance of MBIR (σ2) and tube current-rotation time product (mAs): σ2 ∝ (mAs)−0.4 [K. Li et al., “Statistical model based iterative reconstruction (MBIR) in clinical CT systems: Experimental assessment of noise performance,” Med. Phys. 41, 041906 (15pp.) (2014)]. To examine whether the same power-law works for in vivo cases, experimental data from two types of in vivo studies were analyzed in this paper. All scans were performed with a 64-slice diagnostic CT scanner (Discovery CT750 HD, GE Healthcare) and reconstructed with both FBP and a MBIR method (Veo, GE Healthcare). An Institutional Animal Care and Use Committee-approved in vivo animal study was performed with an adult swine at six mAs levels (10–290). Additionally, human subject data (a total of 110 subjects) acquired from an IRB-approved clinical trial were analyzed. In this clinical trial, a reduced-mAs scan was performed immediately following the standard mAs scan; the specific mAs used for the two scans varied across human subjects and were determined based on patient size and clinical indications. The measurements of σ2 were performed at different mAs by drawing regions-of-interest (ROIs) in the liver and the subcutaneous fat. By applying a linear least-squares regression, the β values in the power-law relationship σ2 ∝ (mAs)−β were measured for the in vivo data and compared with the value found in phantom experiments. Results: For the in vivo swine study, an exponent of β = 0.43 was found for MBIR, and the coefficient of determination (R2) for the corresponding least-squares power-law regression was 0.971. As a reference, the β and R2 values for FBP were found to be 0.98 and 0.997, respectively, from the same study, which are consistent with the well-known σ2 ∝ (mAs)−1.0 relationship for linear CT systems. For the human subject study, the measured β values for the MBIR images were 0.41 ± 0.12 in the liver and 0.37 ± 0.12 in subcutaneous fat. In comparison, the β values for the FBP images were 1.04 ± 0.10 in the liver and 0.97 ± 0.12 in subcutaneous fat. The β values of MBIR and FBP obtained from the in vivo studies were found to be statistically equivalent to the corresponding β values from the phantom study within an equivalency interval of [ − 0.1, 0.1] (p < 0.05); across MBIR and FBP, the difference in β was statistically significant (p < 0.05). Conclusions: Despite the nonlinear nature of the MBIR method, the power-law relationship, σ2 ∝ (mAs)−0.4, found from phantom studies can be applied to in vivo animal and human subject studies. PMID:26843232
Ultrasmooth Perovskite Film via Mixed Anti-Solvent Strategy with Improved Efficiency.
Yu, Yu; Yang, Songwang; Lei, Lei; Cao, Qipeng; Shao, Jun; Zhang, Sheng; Liu, Yan
2017-02-01
Most antisolvents employed in previous research were miscible with perovskite precursor solution. They always led to fast formation of perovskite even if the intermediate stage existed, which was not beneficial to obtain high quality perovskite films and made the formation process less controllable. In this work, a novel ethyl ether/n-hexane mixed antisolvent (MAS) was used to achieve high nucleation density and slow down the formation process of perovskite, producing films with improved orientation of grains and ultrasmooth surfaces. These high quality films exhibited efficient charge transport at the interface of perovskite/hole transport material and perovskite solar cells based on these films showed greatly improved performance with the best power conversion efficiency of 17.08%. This work also proposed a selection principle of MAS and showed that solvent engineering by designing the mixed antisolvent system can lead to the fabrication of high-performance perovskite solar cells.
Astrometric Calibration and Performance of the Dark Energy Camera
Bernstein, G. M.; Armstrong, R.; Plazas, A. A.; ...
2017-05-30
We characterize the ability of the Dark Energy Camera (DECam) to perform relative astrometry across its 500 Mpix, 3more » $deg^2$ science field of view, and across 4 years of operation. This is done using internal comparisons of $~ 4 x 10^7$ measurements of high-S/N stellar images obtained in repeat visits to fields of moderate stellar density, with the telescope dithered to move the sources around the array. An empirical astrometric model includes terms for: optical distortions; stray electric fields in the CCD detectors; chromatic terms in the instrumental and atmospheric optics; shifts in CCD relative positions of up to $$\\approx 10 \\mu m$$ when the DECam temperature cycles; and low-order distortions to each exposure from changes in atmospheric refraction and telescope alignment. Errors in this astrometric model are dominated by stochastic variations with typical amplitudes of 10-30 mas (in a 30 s exposure) and $$5^{\\prime}-10^{\\prime}$$ arcmin coherence length, plausibly attributed to Kolmogorov-spectrum atmospheric turbulence. The size of these atmospheric distortions is not closely related to the seeing. Given an astrometric reference catalog at density $$\\approx 0.7$$ $$arcmin^{-2}$$, e.g. from Gaia, the typical atmospheric distortions can be interpolated to $$\\approx$$ 7 mas RMS accuracy (for 30 s exposures) with $$1^{\\prime}$$ arcmin coherence length for residual errors. Remaining detectable error contributors are 2-4 mas RMS from unmodelled stray electric fields in the devices, and another 2-4 mas RMS from focal plane shifts between camera thermal cycles. Thus the astrometric solution for a single DECam exposure is accurate to 3-6 mas ( $$\\approx$$ 0.02 pixels, or $$\\approx$$ 300 nm) on the focal plane, plus the stochastic atmospheric distortion.« less
VizieR Online Data Catalog: W1J00 and W2J00 Transit Circle Catalogs (Rafferty+, 2016)
NASA Astrophysics Data System (ADS)
Rafferty, T. J.; Holdenried, E. R.; Urban, S. E.
2016-06-01
The W1J00, named because it was the first (of two) Washington transit circle catalog to be referred to the Equinox of J2000.0, is the result of observations made with the Six-inch Transit Circle in Washington, D.C., between September 1977 and July 1982. The observing program was structured to be absolute, in the sense that the positions were not explicitly relying on any previous observations. The absolute positions were defined with respect to an internally consistent frame that was unique to the particular instrument. Following the reductions, comparisons with stars from the Hipparcos Catalogue (European Space Agency 1997) revealed unaccounted for systematic differences on the level of 100-200mas. It was decided, therefore, to include data on both the absolute positions reduced in way common to many past Washington transit circle catalogs, as well as the positions differentially adjusted to the system of the Hipparcos Catalog. The W1J00 contains mean positions of 7267 stars and 4383 observations of solar system objects. The majority of the stars fall into two categories; those from the Fifth Fundamental Catalog (FK5; Fricke et al 1988), and those from the Catalog Of 3539 Zodiacal Stars For The Equinox 1950.0 (Robertson 1940). The solar system objects include the Sun, Mercury, Venus, Mars, Jupiter, Saturn, Uranus, Neptune, eight minor planets (Eunomia, Flora, Hebe, Iris, Juno, Metis, Pallas, and Vesta), and the dwarf planet Ceres. Characteristics of the W1J00 catalog: Category Range Average ------------------------------------------------------------- Magnitudes -1.6 to 10.4 7.18 RA standard errors of the mean 15 to 460 mas 98 mas Dec standard errors of the mean 10 to 400 mas 107 mas RA Number of observations / star 3 to 187 10 Dec Number of observations / star 2 to 179 10 Declination coverage -39 to +90 degrees ------------------------------------------------------------- Details of the W1J00 can be found in Rafferty, Holdenried, and Urban (2016, Publ. USNO, 2nd series, vol. XXVII (part 1)). The W2J00 is the result of observations made with the Six-inch Transit Circle in Washington, D.C., and the Seven-inch Transit Circle at the Black Birch station near Blenheim, New Zealand. It is named as such because it was the second (of two) transit circle catalogs to be referred to the Equinox of J2000.0, and reduced at the Washington D.C. headquarters of the U.S. Naval Observatory. It is sometimes referred to as the "Pole-to-Pole" program due to the fact that the telescopes were situated at latitudes such that a fundamental determination could be made of the azimuth using circumpolar stars of both the northern and southern sky. The observations were made between April 1985 and February 1996. The W2J00 project is the latest and largest of a long series of transit circle catalogs produced by the U.S. Naval Observatory. It is also, because of advancing technologies, certainly the last. The observing program was structured to be absolute, in the sense that the reported positions were not to explicitly rely on previous observations. However, with the availability of Hipparcos observational data, it was decided to differentially adjust the observations to the ICRF using the Hipparcos star positions (ESA, 1997, Cat. I/239). A catalog on the ICRF was judged be more useful than one tied to the dynamical reference frame, as was the tradition. The W2J00 contains mean positions of 44,395 globally distributed stars, 5048 observations of the planets, and 6518 observations of the brighter minor planets. The majority of stars are FK stars (Fricke, et al., 1988, Cat. I/149 and 1991, Cat. I/175) and International Reference Stars (IRS) (Corbin, 1991, Cat. I/172). The solar system objects include Mars, Jupiter, Saturn, Uranus, Neptune, twelve minor planets (Amphitrite, Eunomia, Flora, Hebe, Hygiea, Iris, Juno, Melphomene, Metis, Nemausa, Pallas, and Vesta), and the dwarf planet Ceres. Daytime observations of the Sun, Mercury, Venus, Mars, and bright stars were made but not included in the final catalog due to the problems inherent in reducing observations made in the daylight. The W2J00 observing program used both the Six-inch Transit Circle and Seven-inch Transit Circle. Final positions are a combination of observations from both telescopes (for those stars in common). The authors have decided to present not only the combined positions, but the individual telescope's positions should future researchers decide to investigate the data based on which instrument was used. Characteristics of the W2J00 catalog: Category Range Average ------------------------------------------------------------- Magnitudes -1.6 to 9.91 6.84 RA standard errors of the mean 3 to 441 mas 68 mas Dec standard errors of the mean 1 to 448 mas 76 mas RA Number of observations / star 3 to 411 14 Dec Number of observations / star 2 to 418 14 Declination coverage -90 to +90 degrees ------------------------------------------------------------- Details of the W2J00 can be found in Holdenried and Rafferty (2016, PUSNO, 2nd series, vol. XXVII (part 2)). (4 data files).
Zheng, Xiaoming
2017-12-01
The purpose of this work was to examine the effects of relationship functions between diagnostic image quality and radiation dose on the governing equations for image acquisition parameter variations in X-ray imaging. Various equations were derived for the optimal selection of peak kilovoltage (kVp) and exposure parameter (milliAmpere second, mAs) in computed tomography (CT), computed radiography (CR), and direct digital radiography. Logistic, logarithmic, and linear functions were employed to establish the relationship between radiation dose and diagnostic image quality. The radiation dose to the patient, as a function of image acquisition parameters (kVp, mAs) and patient size (d), was used in radiation dose and image quality optimization. Both logistic and logarithmic functions resulted in the same governing equation for optimal selection of image acquisition parameters using a dose efficiency index. For image quality as a linear function of radiation dose, the same governing equation was derived from the linear relationship. The general equations should be used in guiding clinical X-ray imaging through optimal selection of image acquisition parameters. The radiation dose to the patient could be reduced from current levels in medical X-ray imaging.
Methods for CT automatic exposure control protocol translation between scanner platforms.
McKenney, Sarah E; Seibert, J Anthony; Lamba, Ramit; Boone, John M
2014-03-01
An imaging facility with a diverse fleet of CT scanners faces considerable challenges when propagating CT protocols with consistent image quality and patient dose across scanner makes and models. Although some protocol parameters can comfortably remain constant among scanners (eg, tube voltage, gantry rotation time), the automatic exposure control (AEC) parameter, which selects the overall mA level during tube current modulation, is difficult to match among scanners, especially from different CT manufacturers. Objective methods for converting tube current modulation protocols among CT scanners were developed. Three CT scanners were investigated, a GE LightSpeed 16 scanner, a GE VCT scanner, and a Siemens Definition AS+ scanner. Translation of the AEC parameters such as noise index and quality reference mAs across CT scanners was specifically investigated. A variable-diameter poly(methyl methacrylate) phantom was imaged on the 3 scanners using a range of AEC parameters for each scanner. The phantom consisted of 5 cylindrical sections with diameters of 13, 16, 20, 25, and 32 cm. The protocol translation scheme was based on matching either the volumetric CT dose index or image noise (in Hounsfield units) between two different CT scanners. A series of analytic fit functions, corresponding to different patient sizes (phantom diameters), were developed from the measured CT data. These functions relate the AEC metric of the reference scanner, the GE LightSpeed 16 in this case, to the AEC metric of a secondary scanner. When translating protocols between different models of CT scanners (from the GE LightSpeed 16 reference scanner to the GE VCT system), the translation functions were linear. However, a power-law function was necessary to convert the AEC functions of the GE LightSpeed 16 reference scanner to the Siemens Definition AS+ secondary scanner, because of differences in the AEC functionality designed by these two companies. Protocol translation on the basis of quantitative metrics (volumetric CT dose index or measured image noise) is feasible. Protocol translation has a dependency on patient size, especially between the GE and Siemens systems. Translation schemes that preserve dose levels may not produce identical image quality. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.
SU-E-P-49: Evaluation of Image Quality and Radiation Dose of Various Unenhanced Head CT Protocols
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, L; Khan, M; Alapati, K
2015-06-15
Purpose: To evaluate the diagnostic value of various unenhanced head CT protocols and predicate acceptable radiation dose level for head CT exam. Methods: Our retrospective analysis included 3 groups, 20 patients per group, who underwent clinical routine unenhanced adult head CT examination. All exams were performed axially with 120 kVp. Three protocols, 380 mAs without iterative reconstruction and automAs, 340 mAs with iterative reconstruction without automAs, 340 mAs with iterative reconstruction and automAs, were applied on each group patients respectively. The images were reconstructed with H30, J30 for brain window and H60, J70 for bone window. Images acquired with threemore » protocols were randomized and blindly reviewed by three radiologists. A 5 point scale was used to rate each exam The percentage of exam score above 3 and average scores of each protocol were calculated for each reviewer and tissue types. Results: For protocols without automAs, the average scores of bone window with iterative reconstruction were higher than those without iterative reconstruction for each reviewer although the radiation dose was 10 percentage lower. 100 percentage exams were scored 3 or higher and the average scores were above 4 for both brain and bone reconstructions. The CTDIvols are 64.4 and 57.8 mGy of 380 and 340 mAs, respectively. With automAs, the radiation dose varied with head size, resulting in 47.5 mGy average CTDIvol between 39.5 and 56.5 mGy. 93 and 98 percentage exams were scored great than 3 for brain and bone windows, respectively. The diagnostic confidence level and image quality of exams with AutomAs were less than those without AutomAs for each reviewer. Conclusion: According to these results, the mAs was reduced to 300 with automAs OFF for head CT exam. The radiation dose was 20 percentage lower than the original protocol and the CTDIvol was reduced to 51.2 mGy.« less
Rafii, Mahroukh; Elango, Rajavel; Ball, Ronald O; Pencharz, Paul B; Courtney-Martin, Glenda
2018-06-01
Maize is a staple food in many regions of the world, particularly in Africa and Latin America. However, maize protein is limiting in the indispensable amino acids lysine and tryptophan, making its protein of poor quality. The main objective of this study was to determine the protein quality of white African cornmeal by determining the metabolic availability (MA) of lysine and tryptophan. To determine the MA of lysine, 4 amounts of l-lysine (10, 13, 16, and 18 mg · kg-1 · d-1 totaling 28.6%, 37.1%, 45.7%, and 51.4% of the mean lysine requirement of 35 mg · kg-1 · d-1, respectively) were studied in 6 healthy young men in a repeated-measures design. To determine the MA of tryptophan, 4 amounts of l-tryptophan (0.5, 1, 1.5, and 2 mg · kg-1 · d-1 totaling 12.5%, 25.0%, 37.5%, and 50.0% of the mean tryptophan requirement of 4 mg · kg-1 · d-1, respectively) were studied in 7 healthy young men in a repeated-measures design. The MAs of lysine and tryptophan were estimated by comparing the indicator amino acid oxidation (IAAO) response with varying intakes of lysine and tryptophan in cooked white cornmeal compared with the IAAO response to l-lysine and l-tryptophan intakes in the reference protein (crystalline amino acid mixture patterned after egg protein) with the use of the slope ratio method. The MAs of lysine and tryptophan from African cooked white cornmeal were 71% and 80%, respectively. Our study provides a robust estimate of the availability of lysine and tryptophan in African white maize to healthy young men. This estimate provides a basis for postproduction fortification or supplementation of maize-based diets. This trial was registered at www.clinicaltrials.gov as NCT02402179.
Structural Biology of Supramolecular Assemblies by Magic Angle Spinning NMR Spectroscopy
Quinn, Caitlin M.; Polenova, Tatyana
2017-01-01
In recent years, exciting developments in instrument technology and experimental methodology have advanced the field of magic angle spinning (MAS) NMR to new heights. Contemporary MAS NMR yields atomic-level insights into structure and dynamics of an astounding range of biological systems, many of which cannot be studied by other methods. With the advent of fast magic angle spinning, proton detection, and novel pulse sequences, large supramolecular assemblies, such as cytoskeletal proteins and intact viruses, are now accessible for detailed analysis. In this review, we will discuss the current MAS NMR methodologies that enable characterization of complex biomolecular systems and will present examples of applications to several classes of assemblies comprising bacterial and mammalian cytoskeleton as well as HIV-1 and bacteriophage viruses. The body of work reviewed herein is representative of the recent advancements in the field, with respect to the complexity of the systems studied, the quality of the data, and the significance to the biology. PMID:28093096
DOE Office of Scientific and Technical Information (OSTI.GOV)
Knight, Stephen P, E-mail: stephen.knight@health.qld.gov.au
The aim of this review was to develop a radiographic optimisation strategy to make use of digital radiography (DR) and needle phosphor computerised radiography (CR) detectors, in order to lower radiation dose and improve image quality for paediatrics. This review was based on evidence-based practice, of which a component was a review of the relevant literature. The resulting exposure chart was developed with two distinct groups of exposure optimisation strategies – body exposures (for head, trunk, humerus, femur) and distal extremity exposures (elbow to finger, knee to toe). Exposure variables manipulated included kilovoltage peak (kVp), target detector exposure and milli-ampere-secondsmore » (mAs), automatic exposure control (AEC), additional beam filtration, and use of antiscatter grid. Mean dose area product (DAP) reductions of up to 83% for anterior–posterior (AP)/posterior–anterior (PA) abdomen projections were recorded postoptimisation due to manipulation of multiple-exposure variables. For body exposures, the target EI and detector exposure, and thus the required mAs were typically 20% less postoptimisation. Image quality for some distal extremity exposures was improved by lowering kVp and increasing mAs around constant entrance skin dose. It is recommended that purchasing digital X-ray equipment with high detective quantum efficiency detectors, and then optimising the exposure chart for use with these detectors is of high importance for sites performing paediatric imaging. Multiple-exposure variables may need to be manipulated to achieve optimal outcomes.« less
NASA Astrophysics Data System (ADS)
de Gois, Jefferson S.; Van Malderen, Stijn J. M.; Cadorim, Heloisa R.; Welz, Bernhard; Vanhaecke, Frank
2017-06-01
This work describes the development and comparison of two methods for the direct determination of Br in polymer samples via solid sampling, one using laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) and the other using high-resolution continuum source graphite furnace molecular absorption spectrometry with direct solid sample analysis (HR-CS SS-GF MAS). The methods were optimized and their accuracy was evaluated by comparing the results obtained for 6 polymeric certified reference materials (CRMs) with the corresponding certified values. For Br determination with LA-ICP-MS, the 79Br+ signal could be monitored interference-free. For Br determination via HR-CS SS-GF MAS, the CaBr molecule was monitored at 625.315 nm with integration of the central pixel ± 1. Bromine quantification by LA-ICP-MS was performed via external calibration against a single CRM while using the 12C+ signal as an internal standard. With HR-CS SS-GF MAS, Br quantification could be accomplished using external calibration against aqueous standard solutions. Except for one LA-ICP-MS result, the concentrations obtained with both techniques were in agreement with the certified values within the experimental uncertainty as evidenced using a t-test (95% confidence level). The limit of quantification was determined to be 100 μg g- 1 Br for LA-ICP-MS and 10 μg g- 1 Br for HR-CS SS-GF MAS.
Contributions to reference systems from Lunar Laser Ranging using the IfE analysis model
NASA Astrophysics Data System (ADS)
Hofmann, Franz; Biskupek, Liliane; Müller, Jürgen
2018-01-01
Lunar Laser Ranging (LLR) provides various quantities related to reference frames like Earth orientation parameters, coordinates and velocities of ground stations in the Earth-fixed frame and selenocentric coordinates of the lunar retro-reflectors. This paper presents the recent results from LLR data analysis at the Institut für Erdmessung, Leibniz Universität Hannover, based on all LLR data up to the end of 2016. The estimates of long-periodic nutation coefficients with periods between 13.6 days and 18.6 years are obtained with an accuracy in the order of 0.05-0.7 milliarcseconds (mas). Estimations of the Earth rotation phase Δ UT are accurate at the level of 0.032 ms if more than 14 normal points per night are included. The tie between the dynamical ephemeris frame to the kinematic celestial frame is estimated from pure LLR observations by two angles and their rates with an accuracy of 0.25 and 0.02 mas per year. The estimated station coordinates and velocities are compared to the ITRF2014 solution and the geometry of the retro-reflector network with the DE430 solution. The given accuracies represent 3 times formal errors of the parameter fit. The accuracy for Δ UT is based on the standard deviation of the estimates with respect to the reference C04 solution.
Photometry and Astrometry of the Jovian satellites Amalthea and Thebe
NASA Astrophysics Data System (ADS)
Saquet, Eléonore; Emelyanov, Nicolai; Colas, François; Robert, Vincent; Arlot, Jean-Eudes
2016-10-01
During the 2014-2015 campaign of mutual events, we realized ground-based observations of Amalthea (JV) and Thebe (JXIV). We recorded two eclipses of Amalthea and, for the first time, one of Thebe by the Galilean moons. We used the 1-m telescope at Pic du Midi Observatory with an IR filter and a mask placed over the planetary image to reduce the light intensity of Jupiter. A third observation of Amalthea was taken at Saint-Sulpice Observatory with a 60-cm telescope using a methane filter (890 nm) and a deep absorption band to decrease the contrast between the planet and the satellites. We provide astrometric results derived from the photometry with an overall accuracy of 34 mas, or 100 km at Jupiter.In the same time, we realized 45 astrometric observations of Amalthea and 41 of Thebe to compare the photometric technique with direct astrometry, using the UCAC4 reference star catalog. We provide astrometric results with an overall accuracy of 100 mas for Amalthea, or 300 km at Jupiter, and 90 mas for Thebe, or 270 km at Jupiter. These results are better than those from previous ground-based and old reduced space measurements.
CCD astrometric observations of Amalthea and Thebe in the Gaia era
NASA Astrophysics Data System (ADS)
Robert, V.; Saquet, E.; Colas, F.; Arlot, J.-E.
2017-05-01
In the framework of the 2014-2015 campaign of mutual events, we observed Jupiter's inner satellites Amalthea (JV) and Thebe (JXIV). We focused on estimating whether the positioning accuracy determined from direct astrometry could compete with that derived from photometric observations of eclipses, for dynamical purposes. We present the analysis of 35 observations of Amalthea and 19 observations of Thebe realized with the 1-m telescope at the Pic du Midi observatory during three nights in 2015, January and April. The images were reduced through an optimal process that includes image and spherical corrections using the Gaia-DR1 catalogue to provide the most accurate equatorial (RA, Dec.) positions. We compared the observed positions of both satellites with the theoretical positions from JPL JUP310 satellite ephemerides and from the IMCCE INPOP13c planetary ephemeris. The values of rms (O-C) in equatorial positions are ±112 mas for the Amalthea observations, or 330 km at Jupiter, and ±90 mas for the Thebe observations, or 270 km at Jupiter. Using the Gaia-DR1 catalogue allowed us to eliminate systematic errors due to the star references up to 120 mas, or 350 km at Jupiter, by comparison with the UCAC4 catalogue.
Methodological and Reporting Quality of Systematic Reviews and Meta-analyses in Endodontics.
Nagendrababu, Venkateshbabu; Pulikkotil, Shaju Jacob; Sultan, Omer Sheriff; Jayaraman, Jayakumar; Peters, Ove A
2018-06-01
The aim of this systematic review (SR) was to evaluate the quality of SRs and meta-analyses (MAs) in endodontics. A comprehensive literature search was conducted to identify relevant articles in the electronic databases from January 2000 to June 2017. Two reviewers independently assessed the articles for eligibility and data extraction. SRs and MAs on interventional studies with a minimum of 2 therapeutic strategies in endodontics were included in this SR. Methodologic and reporting quality were assessed using A Measurement Tool to Assess Systematic Reviews (AMSTAR) and Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA), respectively. The interobserver reliability was calculated using the Cohen kappa statistic. Statistical analysis with the level of significance at P < .05 was performed using Kruskal-Wallis tests and simple linear regression analysis. A total of 30 articles were selected for the current SR. Using AMSTAR, the item related to the scientific quality of studies used in conclusion was adhered by less than 40% of studies. Using PRISMA, 3 items were reported by less than 40% of studies, which were on objectives, protocol registration, and funding. No association was evident comparing the number of authors and country with quality. Statistical significance was observed when quality was compared among journals, with studies published as Cochrane reviews superior to those published in other journals. AMSTAR and PRISMA scores were significantly related. SRs in endodontics showed variability in both methodologic and reporting quality. Copyright © 2018 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Version 1 of the Hubble Source Catalog
NASA Astrophysics Data System (ADS)
Whitmore, Bradley C.; Allam, Sahar S.; Budavári, Tamás; Casertano, Stefano; Downes, Ronald A.; Donaldson, Thomas; Fall, S. Michael; Lubow, Stephen H.; Quick, Lee; Strolger, Louis-Gregory; Wallace, Geoff; White, Richard L.
2016-06-01
The Hubble Source Catalog is designed to help optimize science from the Hubble Space Telescope (HST) by combining the tens of thousands of visit-based source lists in the Hubble Legacy Archive (HLA) into a single master catalog. Version 1 of the Hubble Source Catalog includes WFPC2, ACS/WFC, WFC3/UVIS, and WFC3/IR photometric data generated using SExtractor software to produce the individual source lists. The catalog includes roughly 80 million detections of 30 million objects involving 112 different detector/filter combinations, and about 160,000 HST exposures. Source lists from Data Release 8 of the HLA are matched using an algorithm developed by Budavári & Lubow. The mean photometric accuracy for the catalog as a whole is better than 0.10 mag, with relative accuracy as good as 0.02 mag in certain circumstances (e.g., bright isolated stars). The relative astrometric residuals are typically within 10 mas, with a value for the mode (I.e., most common value) of 2.3 mas. The absolute astrometric accuracy is better than 0''\\hspace{-0.5em}. 1 for most sources, but can be much larger for a fraction of fields that could not be matched to the PanSTARRS, SDSS, or 2MASS reference systems. In this paper we describe the database design with emphasis on those aspects that enable the users to fully exploit the catalog while avoiding common misunderstandings and potential pitfalls. We provide usage examples to illustrate some of the science capabilities and data quality characteristics, and briefly discuss plans for future improvements to the Hubble Source Catalog.
Version 1 of the Hubble Source Catalog
Whitmore, Bradley C.; Allam, Sahar S.; Budavari, Tamas; ...
2016-05-11
The Hubble Source Catalog is designed to help optimize science from the Hubble Space Telescope by combining the tens of thousands of visit-based source lists in the Hubble Legacy Archive into a single master catalog. Version 1 of the Hubble Source Catalog includes WFPC2, ACS/WFC, WFC3/UVIS, and WFC3/IR photometric data generated using SExtractor software to produce the individual source lists. The catalog includes roughly 80 million detections of 30 million objects involving 112 different detector/filter combinations, and about 160 thousand HST exposures. Source lists from Data Release 8 of the Hubble Legacy Archive are matched using an algorithm developed by Budavari & Lubow (2012). The mean photometric accuracy for the catalog as a whole is better than 0.10 mag, with relative accuracy as good as 0.02 mag in certain circumstances (e.g., bright isolated stars). The relative astrometric residuals are typically within 10 mas, with a value for the mode (i.e., most common value) of 2.3 mas. The absolute astrometric accuracy is better thanmore » $$\\sim$$0.1 arcsec for most sources, but can be much larger for a fraction of fields that could not be matched to the PanSTARRS, SDSS, or 2MASS reference systems. In this paper we describe the database design with emphasis on those aspects that enable the users to fully exploit the catalog while avoiding common misunderstandings and potential pitfalls. Here, we provide usage examples to illustrate some of the science capabilities and data quality characteristics, and briefly discuss plans for future improvements to the Hubble Source Catalog.« less
Pluto: improved astrometry from 19 years of observations
NASA Astrophysics Data System (ADS)
Benedetti-Rossi, G.; Vieira Martins, R.; Camargo, J. I. B.; Assafin, M.; Braga-Ribas, F.
2014-10-01
Context. We present astrometric positions of Pluto, consistent with the International Celestial Reference System, from 4412 CCD frames observed over 120 nights with three telescopes at the Observatório do Pico dos Dias in Brazil, covering a time span from 1995 to 2013, and also 145 frames observed over 11 nights in 2007 and 2009 with the ESO/MPG 2.2m telescope equipped with the Wide Field Imager (WFI). Aims: Our aim is to contribute to the study and improvement of the orbit of Pluto with new astrometric methods and positions. Methods: All astrometric positions of Pluto were reduced with the Platform for Reduction of Astronomical Images Automatically (PRAIA), using the USNO CCD Astrograph Catalogue 4 (UCAC4) as the reference catalog. We also used the planetary ephemeris DE421+plu021 for comparisons. The positions were corrected for differential chromatic refraction. The (x, y) center of Pluto was determined from corrections to the measured photocenter, which was contaminated by Charon. The corrections were obtained with an original procedure based on analytical expressions derived from a two-dimensional Gaussian function i.e. the point spread function PSF fitted to the images to derive the (x, y) measurements. Results: We obtained mean values of 4 mas and 37 mas for right ascension and declination, and standard deviations of σα = 45 mas and σδ = 49 mas, for the offsets in the sense observed minus ephemeris position, after the corrections. We confirm the presence of a linear drift in the ephemeris declinations from 2005 on, also obtained from stellar occultations. Conclusions: We present astrometric positions of Pluto for 19 years of observations in Brazil. The positions, corrected for differential chromatic refraction and Pluto/Charon photocenter effects, presented the same behavior as obtained from stellar occultations, with a drift in declinations of about 100 mas since 2005. The results indicate that the DE421 Pluto ephemeris used in this work need to be corrected. Full Table 4 is only available in electronic form at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (ftp://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/570/A86Based on observations made at Laboratório Nacional de Astrofísica (LNA), Itajubá-MG, Brazil.Partially based on observations through the ESO runs 079.A-9202(A), 075.C-0154, 077.C-0283, and 079.C-0345.
Oral Appliances for Obstructive Sleep Apnea
2009-01-01
Executive Summary Objective The objective of this review was to determine the clinical effectiveness of oral appliances compared to ‘no treatment’, continuous positive airway pressure (CPAP), or surgery for the management of obstructive sleep apnea (OSA). Clinical Need: Condition and Target Population OSA is characterized by repeated occurrences of upper airway collapse and obstruction during sleep. The condition leads to excessive daytime sleepiness, diminished quality of life, and increased risks of accidents, cardiovascular disease and death. In the general population, the prevalence of OSA is estimated to be 4% in men and 2% in women. Risk factors for OSA include obesity, male gender, increasing age, alcohol use, sedative use, and a family history of OSA. Description of Oral Appliances Oral appliances for OSA fall into two broad categories: mandibular advancement splints (MAS), also known as mandibular repositioning devices, and tongue repositioning or retaining devices. The aim of MAS devices is to advance the mandible forward slightly to enlarge the upper airway and prevent it from collapsing. Similarly, tongue repositioning devices suction the tongue forward to prevent it from falling back and obstructing the airway during sleep. The alternatives to oral appliances include continuous positive airway pressure (CPAP) devices, surgery, drug therapy, positional devices, and lifestyle modification. CPAP is the gold standard of treatment, but despite its effectiveness, compliance rates for CPAP have declined because required systems are noisy and because wearing the mask can be uncomfortable, causing claustrophobia in some users. Evidence-Based Analysis Methods Research Questions Are oral appliances effective in improving sleep-disordered breathing in patients with OSA compared to alternative treatments? Are there safety concerns with oral appliances? What is the evidence regarding patient preference, quality of life, and compliance for oral appliances? If effective, are oral appliances cost effective? Literature Search A literature search was conducted up to February 2009. Systematic reviews, meta-analyses and randomized controlled trials (RCTs) with more than 20 adults with OSA were eligible for inclusion. The primary outcomes of interest were the Apnea Hypopnea Index (AHI), measures of daytime sleepiness, patient preference, compliance, and adverse events. Summary of Findings Five systematic reviews and 16 RCTs that met the inclusion criteria were identified. The systematic reviews consistently concluded that CPAP was more effective than oral appliances at improving sleep disordered breathing, although there may be a niche area for the latter, especially among those with mild OSA as CPAP is difficult to tolerate by some users. Based on the results of the RCTs analyzed for this review, MAS devices are less effective than CPAP when AHI is used as the outcome of interest. MAS devices were shown to decrease AHI levels, but whether this reduction is clinically meaningful is uncertain. The Epworth Sleepiness Scale (ESS) was not able to achieve statistical significance in comparisons of MAS versus CPAP and MAS versus placebo. Nonetheless, after treatment with either MAS or CPAP, patients seem to be able to achieve normal ESS levels. The ESS has substantial limitations including its subjective nature and low construct validity (i.e. it is unclear if the scale is an accurate measure of sleepiness). Adverse events among patients with MAS devices in the RCTs were common, but mostly mild and transient. Jaw discomfort was the most commonly reported adverse event. Based on the results of the RCTs, compliance does not seem to be better or worse with MAS or CPAP. Similarly, there is no clear patient preference for MAS or CPAP among the studies reporting preference and satisfaction. Keywords Obstructive sleep apnea, oral appliances, mandibular advancement splints, tongue repositioning devices PMID:23074535
The Kinematics Parameters of the Galaxy Using Data of Modern Astrometric Catalogues
NASA Astrophysics Data System (ADS)
Akhmetov, V. S.; Fedorov, P. N.; Velichko, A. B.; Shulga, V. M.
Based on the Ogorodnikov-Milne model, we analyze the proper motions of XPM2, UCAC4 and PPMXL stars. To estimate distances to the stars we used the method of statistical parallaxes herewith the random errors of the distance estimations do not exceed 10%. The method of statistical parallaxes was used to estimate the distances to stars with random errors no larger than 14%. The linear solar velocity relative to the local standard of rest, which is well determined for the local entroid (d 150 p), was used as a reference. We have established that the model component that describes the rotation of all stars under consideration about the Galactic Y axis differs from zero. For the distant (d < 1000 pc) PPMXL and UCAC4 stars, the mean rotation about the Galactic Y axis has been found to be M-13 = -0.75± 0.04 mas yr-1. As for distances greater than 1 kpc M-13>derived from the data of only XPM2 catalogue becomes positive and exceeds 0.5 mas yr-1. We interpret this rotation found using the distant stars as a residual rotation of the ICRS/Tycho-2 system relative to the inertial reference frame.
Monitoring of Earth Rotation by VLBI
NASA Technical Reports Server (NTRS)
Ma., Chopo; Macmillan, D. S.
2000-01-01
Monitoring Earth rotation with Very Long Baseline Interferometry (VLBI) has unique potential because of direct access to the Celestial Reference System (CRF and Terrestrial Reference System (TRF) and the feasibility of re-analyzing the entire data set. While formal precision of better than 0.045 mas for pole and 0.002 ms for UT 1 has been seen in the best 24-hr data, the accuracy of the Earth Orientation Parameter (EOP) time series as a whole is subject to logistical, operational, analytical and conceptual constraints. The current issues related to the VLBI data set and the CORE program for greater time resolution such as analysis consistency, network jitter and reference frame stability will be discussed.
Predicting Earth orientation changes from global forecasts of atmosphere-hydrosphere dynamics
NASA Astrophysics Data System (ADS)
Dobslaw, Henryk; Dill, Robert
2018-02-01
Effective Angular Momentum (EAM) functions obtained from global numerical simulations of atmosphere, ocean, and land surface dynamics are routinely processed by the Earth System Modelling group at Deutsches GeoForschungsZentrum. EAM functions are available since January 1976 with up to 3 h temporal resolution. Additionally, 6 days-long EAM forecasts are routinely published every day. Based on hindcast experiments with 305 individual predictions distributed over 15 months, we demonstrate that EAM forecasts improve the prediction accuracy of the Earth Orientation Parameters at all forecast horizons between 1 and 6 days. At day 6, prediction accuracy improves down to 1.76 mas for the terrestrial pole offset, and 2.6 mas for Δ UT1, which correspond to an accuracy increase of about 41% over predictions published in Bulletin A by the International Earth Rotation and Reference System Service.
Quality Analysis of Ceramic Tent Product With Six Sigma Method in PT. Mas Keramik KIA
NASA Astrophysics Data System (ADS)
Suryadi, A.; Ardiansyah P., F.; Ngatilah, Y.
2018-01-01
PT. KIA Keramik Mas is a company engaged in manufacturing, which produces ceramic tiles, one of the problems faced by this company is the number of defects found, in the July - December 2015 amounted to 6,259,945 units producing tiles and discovered defects by 960 683 units with an object research is ceramic tile products, among some of the defects found several characteristics of defects that occur include rugged body, coincide, grainy, scratched, and colors distorted. The purpose of this study was to determine the quality of the product and propose improvements that reduce the number of such defects, using quality control methods that Six Sigma. Six Sigma is used to generate a defect that does not exceed 3.4 DPMO (defects per million opportunities) or zero defect which is an approach to calculate the number of defects per million possibilities. Average quality ceramic tile products during the month of July - December 2015 was on a sigma of 3.37 with DPMO of 30 586, which means that one million opportunities that exist there will be 30 586 (3,05%) the possibility that the process of making the ceramic tile defect or defects occur, so to get to the required target of Six Sigma improvement.
New precise astrometric observations of Nereid in 2012-2017
NASA Astrophysics Data System (ADS)
Yu, Y.; Qiao, R. C.; Yan, D.; Cheng, X.; Xi, X. J.; Tang, K.; Luo, H.
2018-03-01
Nereid is one of the most distinctive natural satellites that we know in the Solar system. The orbit of Nereid is highly eccentric and inclined with respect to the equator of its primary, Neptune. Studying Nereid is one of the inspiring ways to acquire better knowledge of the Solar system. Due to its faintness, the ground-based observations of Nereid have been limited and the observation precisions in the past were generally not high. A total of 150 new observed positions of Nereid in the period 2012-2017 were collected by the 0.8 m reflecting telescope at Xinglong station of National Astronomical Observatory and the 2.4 m reflecting telescope at Lijiang station of Yunnan Astronomical Observatory. Thanks to the high-quality reference catalogue Gaia DR1 and suitable processing methods for images, the precision of our new observations of Nereid is 2-3 times higher than those of the previous observations, and the dispersions of our observations are better than 70 mas.
Median prior constrained TV algorithm for sparse view low-dose CT reconstruction.
Liu, Yi; Shangguan, Hong; Zhang, Quan; Zhu, Hongqing; Shu, Huazhong; Gui, Zhiguo
2015-05-01
It is known that lowering the X-ray tube current (mAs) or tube voltage (kVp) and simultaneously reducing the total number of X-ray views (sparse view) is an effective means to achieve low-dose in computed tomography (CT) scan. However, the associated image quality by the conventional filtered back-projection (FBP) usually degrades due to the excessive quantum noise. Although sparse-view CT reconstruction algorithm via total variation (TV), in the scanning protocol of reducing X-ray tube current, has been demonstrated to be able to result in significant radiation dose reduction while maintain image quality, noticeable patchy artifacts still exist in reconstructed images. In this study, to address the problem of patchy artifacts, we proposed a median prior constrained TV regularization to retain the image quality by introducing an auxiliary vector m in register with the object. Specifically, the approximate action of m is to draw, in each iteration, an object voxel toward its own local median, aiming to improve low-dose image quality with sparse-view projection measurements. Subsequently, an alternating optimization algorithm is adopted to optimize the associative objective function. We refer to the median prior constrained TV regularization as "TV_MP" for simplicity. Experimental results on digital phantoms and clinical phantom demonstrated that the proposed TV_MP with appropriate control parameters can not only ensure a higher signal to noise ratio (SNR) of the reconstructed image, but also its resolution compared with the original TV method. Copyright © 2015 Elsevier Ltd. All rights reserved.
Choi, Woneui; Jeong, Heejeong; Choi, Suk-Joo; Kim, Jung-Sun; Roh, Cheong-Rae; Kim, Jong-Hwa
2015-01-01
Objective The aim of this study was to compare the risk factors associated with mild/moderate meconium aspiration syndrome (MAS) with those associated with severe in meconium-stained term neonates. Methods Consecutive singleton term neonates (n=671) with meconium staining at birth from all deliveries (n=14,666) in our institution from January 2006 to December 2012 were included. Both maternal and neonatal variables were examined. Among the study population, for women who underwent the trial of labor (n=644), variables associated with labor were also examined. These variables were compared between the mild/moderate MAS group, the severe MAS group, and the MAS-absent group. Results MAS developed in 10.6% (71/671) of neonates with meconium staining at birth. Among the neonates with MAS, 81.7% had mild MAS, 5.6% had moderate MAS, and 12.7% had severe MAS. The presence of minimal variability was significantly increased in both the mild/moderate and the severe MAS groups. The frequencies of nulliparity, fetal tachycardia, and intrapartum fever were significantly increased in the mild/moderate MAS group, but not in the severe MAS group. While a longer duration of the second stage of labor was significantly associated with mild/moderate MAS, severe MAS was associated with a shorter duration of the second stage. Notably, low mean cord pH (7.165 [6.850-7.375]) was significantly associated with mild/moderate MAS, but not with severe MAS (7.220 [7.021-7.407]) compared with the absence of MAS (7.268 [7.265-7.271]). Conclusion Our data suggest the development of severe MAS is not simply a linear extension of the same risk factors driving mild/moderate MAS. PMID:25629015
Connecting the Dots: From an Easy Method to Computerized Species Determination
Niederegger, Senta; Döge, Klaus-Peter; Peter, Marcus; Eickhölter, Tobias; Mall, Gita
2017-01-01
Differences in growth rate of forensically important dipteran larvae make species determination an essential requisite for an accurate estimation of time since colonization of the body. Interspecific morphological similarities, however, complicate species determination. Muscle attachment site (MAS) patterns on the inside of the cuticula of fly larvae are species specific and grow proportionally with the animal. The patterns can therefore be used for species identification, as well as age estimation in forensically important dipteran larvae. Additionally, in species where determination has proven to be difficult—even when employing genetic methods—this easy and cheap method can be successfully applied. The method was validated for a number of Calliphoridae, as well as Sarcophagidae; for Piophilidae species, however, the method proved to be inapt. The aim of this article is to assess the utility of the MAS method for applications in forensic entomology. Furthermore, the authors are currently engineering automation for pattern acquisition in order to expand the scope of the method. Automation is also required for the fast and reasonable application of MAS for species determination. Using filters on digital microscope pictures and cross-correlating them within their frequency range allows for a calculation of the correlation coefficients. Such pattern recognition permits an automatic comparison of one larva with a database of MAS reference patterns in order to find the correct, or at least the most likely, species. This facilitates species determination in immature stages of forensically important flies and economizes time investment, as rearing to adult flies will no longer be required. PMID:28524106
Xu, H; Hofmeyr, J; Roy, C; Fraser, W D
2007-04-01
Amnioinfusion (AI) is thought to dilute meconium when present in the amniotic fluid and so reduces the risk of meconium aspiration. To evaluate if AI reduces meconium aspiration syndrome (MAS) and other indicators of morbidity in babies born to women with meconium-stained amniotic fluid (MSAF). PubMed, Medline, EMBASE, and the Cochrane Controlled Trials Register from January 1980 to May 30, 2005, using the keywords 'amnioinfusion' and 'meconium'. Randomised trials comparing AI with no AI for women in labour with MSAF. Trial quality was evaluated using pre-established criteria. The following morbidity indicators were assessed: MAS, 5-minute Apgar score < 7, arterial cord pH < 7.2, and caesarean section. Studies were stratified according to the level of peripartum surveillance (standard versus limited). Typical relative risks (RRs) with their 95% confidence intervals were calculated for each outcome using a random effects model. In clinical settings with standard peripartum surveillance, we found no evidence that AI reduced the risk of MAS (RR 0.59, 95% CI 0.28-1.25), 5-minute Apgar score < 7 (RR 0.90, 95% CI 0.58-1.41), or caesarean delivery (RR 0.89, 95% CI 0.73-1.10). In clinical settings with limited peripartum surveillance, AI appeared to reduce the risk of MAS (RR 0.25, 95% CI 0.13-0.47). In clinical settings with standard peripartum surveillance, the evidence does not support the use of AI for MSAF. In settings with limited peripartum surveillance, where complications of MSAF are common, AI appears to reduce the risk of MAS. However, this finding requires confirmation by further studies.
Faudzi, A Y; Amal, N M; Zainal, A O; Lailanor, I; Sirajuddin, H; Taha, M A
2011-03-01
A systematic approach to death registration and reporting is essential for studies and comparison within or between countries. One of the accepted methods in the system is to have medically certified death. The objective of this study was to improve the proportion of medically certified death (MCD) in the state of Malacca. Structured questionnaires were used by Medical Assistants (MAs) in the investigation of the cause of death for non-medically certified deaths. Data on certification of death by MAs in Malacca was analysed and compared with the total deaths obtained from the Department of Statistics. Possible determinants of deaths were investigated. Total deaths in the state of Malacca during the study period from 2000 - 2001 were 5941. About 35% (883/2493) of the total deaths in year 2000 and 45% (1550/3448) in 2001 certified by MAs were examined. By districts, 50.6% were certified in the district of Malacca Tengah, 13.4% Jasin and 36.0% Alor Gajah in 2000; 65.9% occurred in Malacca Tengah, 11.0% Jasin and 23.2% Alor Gajah in 2001. This project helped to increase the percentage of the medically certified deaths in Malacca from 49.8% in year 1998, 49% in 1999 to 73% in 2000 and 85% in 2001. The proportion of MCD in Malacca in 2000 (73%) may be increased to 93% if all MCDs done by MAs were accepted by the Department of Statistics. There is still a high proportion (23.6%) of ill-defined conditions such as old age and sudden death being diagnosed by MAs. The study shows that the quality of mortality data particularly in the percentage of medically certified deaths can be improved.
Beeres, Martin; Bauer, Ralf W; Kerl, Josef M; Vogl, Thomas J; Lee, Clara
2015-01-01
Objectives: The aim of our study was to find out how much energy is applicable in second-generation dual source high-pitch computed tomography (CT) in imaging of the abdomen. Materials and Methods: We examined an upper abdominal phantom using a Somatom Definition Flash CT-Scanner (Siemens, Forchheim, Germany). The study protocol consisted of a scan-series at 100 kV and 120 kV. In each scan series we started with a pitch of 3.2 and reduced it in steps of 0.2, until a pitch of 1.6 was reached. The current was adjusted to the maximum the scanner could achieve. Energy values, image noise, image quality, and radiation exposure were evaluated. Results: For a pitch of 3.2 the maximum applicable current was 142 mAs at 120 kV and in 100 kV the maximum applicable current was 114 mAs. For conventional abdominal imaging, current levels of 200 to 260 mAs are generally used. To achieve similar current levels, we had to decrease the pitch to 1.8 at 100 kV — at this pitch we could perform our imaging at 204 mAs. At a pitch of 2.2 in 120 kV we could apply a current of 206 mAs. Conclusion: We conclude our study by stating that if there is a need for a higher current, we have to reduce the pitch. In a high-pitch dual source CT, we always have to remember where our main focus is, so we can adjust the pitch to the energy we need in the area of the body that has to be imaged, to find answers to the clinical question being raised. PMID:25806137
A deep proper motion catalog within the Sloan digital sky survey footprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Munn, Jeffrey A.; Harris, Hugh C.; Tilleman, Trudy M.
2014-12-01
A new proper motion catalog is presented, combining the Sloan Digital Sky Survey (SDSS) with second epoch observations in the r band within a portion of the SDSS imaging footprint. The new observations were obtained with the 90prime camera on the Steward Observatory Bok 90 inch telescope, and the Array Camera on the U.S. Naval Observatory, Flagstaff Station, 1.3 m telescope. The catalog covers 1098 square degrees to r = 22.0, an additional 1521 square degrees to r = 20.9, plus a further 488 square degrees of lesser quality data. Statistical errors in the proper motions range from 5 masmore » year{sup −1} at the bright end to 15 mas year{sup −1} at the faint end, for a typical epoch difference of six years. Systematic errors are estimated to be roughly 1 mas year{sup −1} for the Array Camera data, and as much as 2–4 mas year{sup −1} for the 90prime data (though typically less). The catalog also includes a second epoch of r band photometry.« less
The Position/Structure Stability of Four ICRF2 Sources
NASA Technical Reports Server (NTRS)
Fomalont, Ed; Johnston, Kenneth; Fey, Alan; Boboltz, Dave; Oyama, Tomoaki; Honma, Mareki
2010-01-01
Four compact radio sources in the International Celestial Reference Frame (ICRF2) catalog were observed using phase referencing with the VLBA at 43, 23, and 8.6-GHz, and with VERA at 23-GHz over a one-year period. The goal was to determine the stability of the radio cores and to assess structure effects associated with positions in the ICRF2. Conclusions are: (1) 43-GHz VLBI high-resolution observations are often needed to determine the location of the radio core. (2) Over the observing period, the relative positions among the four radio cores were constant to 0.02 mas, suggesting that once the true radio core is identified, it remains stationary in the sky to this accuracy. (3) The emission in 0556+238, one of the four sources investigated and one of the 295 ICRF2 defining sources, was dominated by a strong component near the core and moved 0.1 mas during the year. (4) Comparison of the VLBA images at 43, 23, and 8.6-GHz with the ICRF2 positions suggests that the 8-GHz structure is often dominated by a bright non-core component. The measured ICRF2 position can be displaced more than 0.5 mas from the radio core and partake in the motion of the bright jet component.
UCAC1: New Proper Motions for 27 Million Stars on the Southern Hemisphere
NASA Astrophysics Data System (ADS)
Zacharias, N.; Monet, S. Urban D. G.; Platais, I.; Wycoff, G. L.; Zacharias, M. I.; Rafferty, T. J.
The big impact of UCAC on galactic kinematics and dynamics studies will be outlined. The USNO CCD Astrograph (UCA) started an astrometric sky survey in February 1998 at Cerro Tololo, Chile. By January 2000 about 90% of the Southern Hemisphere has been observed and full sky coverage is expected by early 2003. In addition, calibration fields around extragalactic reference frame sources and selected open clusters are observed frequently. The UCAC project is a huge dedicated astrometric survey similar to the AGK2 and AGK3 projects but vastly exceeding those with respect to higher accuracy, limiting magnitude (16th) and full sky coverage. A first catalog (UCAC1) is being published in early 2000 for 27 million stars. Stars in the range of 9 to 14th magnitude have a positional precision of 20 mas. The UCAC1 will utilize positions from the USNO A2.0 catalog for determining proper motions, which are expected to be about 8 mas/yr for this initial release. Higher precision proper motions, expected to be in the 3 to 4 mas/yr range, will be derived utilizing a variety of early epoch data, including re-measuring of the Southern Proper Motion (SPM) survey first epoch plates.
Improved ceramic heat exchanger materials
NASA Technical Reports Server (NTRS)
Rauch, H. W.
1980-01-01
The development and evaluation of materials for potential application as heat exchanger structures in automotive gas turbine engines is discussed. Test specimens in the form of small monolithic bars were evaluated for thermal expansion and dimensional stability before and after exposure to sea salt and sulfuric acid, followed by short and long term cycling at temperatures up to 1200 C. The material finally selected, GE-7808, consists of the oxides, ZrO2-MgO-Al2O3-S1O2, and is described generically as ZrMAS. The original version was based on a commercially available cordierite (MAS) frit. However, a clay/talc mixture was demonstrated to be a satisfactory very low cost source of the cordierite (MAS) phase. Several full size honeycomb regenerator cores, about 10.2 cm thick and 55 cm diameter were fabricated from both the frit and mineral versions of GE-7808. The honeycomb cells in these cores had rectangular dimensions of about 0.5 mm x 2.5 mm and a wall thickness of approximately 0.2 mm. The test data show that GE-7808 is significantly more stable at 1100 C in the presence of sodium than the aluminosilicate reference materials. In addition, thermal exposure up to 1100 C, with and without sodium present, results in essentially no change in thermal expansion of GE-7808.
Subhas, Naveen; Polster, Joshua M; Obuchowski, Nancy A; Primak, Andrew N; Dong, Frank F; Herts, Brian R; Iannotti, Joseph P
2016-08-01
The purpose of this study was to compare iterative metal artifact reduction (iMAR), a new single-energy metal artifact reduction technique, with filtered back projection (FBP) in terms of attenuation values, qualitative image quality, and streak artifacts near shoulder and hip arthroplasties and observer ability with these techniques to detect pathologic lesions near an arthroplasty in a phantom model. Preoperative and postoperative CT scans of 40 shoulder and 21 hip arthroplasties were reviewed. All postoperative scans were obtained using the same technique (140 kVp, 300 quality reference mAs, 128 × 0.6 mm detector collimation) on one of three CT scanners and reconstructed with FBP and iMAR. The attenuation differences in bones and soft tissues between preoperative and postoperative scans at the same location were compared; image quality and streak artifact for both reconstructions were qualitatively graded by two blinded readers. Observer ability and confidence to detect lesions near an arthroplasty in a phantom model were graded. For both readers, iMAR had more accurate attenuation values (p < 0.001), qualitatively better image quality (p < 0.001), and less streak artifact (p < 0.001) in all locations near arthroplasties compared with FBP. Both readers detected more lesions (p ≤ 0.04) with higher confidence (p ≤ 0.01) with iMAR than with FBP in the phantom model. The iMAR technique provided more accurate attenuation values, better image quality, and less streak artifact near hip and shoulder arthroplasties than FBP; iMAR also increased observer ability and confidence to detect pathologic lesions near arthroplasties in a phantom model.
Reverse Induced Fit-Driven MAS-Downstream Transduction: Looking for Metabotropic Agonists.
Pernomian, Larissa; Gomes, Mayara S; de Paula da Silva, Carlos H Tomich; Rosa, Joaquin M C
2017-01-01
Protective effects of MAS activation have spurred clinical interests in developing MAS agonists. However, current bases that drive this process preclude that physiological concentrations of peptide MAS agonists induce an atypical signaling that does not reach the metabotropic efficacy of constitutive activation. Canonical activation of MAS-coupled G proteins is only achieved by supraphysiological concentrations of peptide MAS agonists or physiological concentrations of chemically modified analogues. These pleiotropic differences are because of two overlapped binding domains: one non-metabotropic site that recognizes peptide agonists and one metabotropic domain that recognizes modified analogues. It is feasible that supraphysiological concentrations of peptide MAS agonists undergo to chemical modifications required for binding to metabotropic domain. Receptor oligomerization enhances pharmacological parameters coupled to metabotropic signaling. The formation of receptor-signalosome complex makes the transduction of agonists more adaptive. Considering the recent identification of MAS-signalosome, we aimed to postulate the reverse induced fit hypothesis in which MAS-signalosome would trigger chemical modifications required for agonists bind to MAS metabotropic domain. Here we cover rational perspectives for developing novel metabotropic MAS agonists in the view of the reverse induced-fit hypothesis. Predicting a 3D model of MAS metabotropic domain may guide the screening of chemical modifications required for metabotropic efficacy. Pharmacophore-based virtual screening would select potential metabotropic MAS agonists from virtual libraries from human proteome. Rational perspectives that consider reverse induced fit hypothesis during MAS activation for developing metabotropic MAS agonists represents the best approach in providing MAS ligands with constitutive efficacy at physiological concentrations. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Low-Dose CT of the Paranasal Sinuses: Minimizing X-Ray Exposure with Spectral Shaping.
Wuest, Wolfgang; May, Matthias; Saake, Marc; Brand, Michael; Uder, Michael; Lell, Michael
2016-11-01
Shaping the energy spectrum of the X-ray beam has been shown to be beneficial in low-dose CT. This study's aim was to investigate dose and image quality of tin filtration at 100 kV for pre-operative planning in low-dose paranasal CT imaging in a large patient cohort. In a prospective trial, 129 patients were included. 64 patients were randomly assigned to the study protocol (100 kV with additional tin filtration, 150mAs, 192x0.6-mm slice collimation) and 65 patients to the standard low-dose protocol (100 kV, 50mAs, 128 × 0.6-mm slice collimation). To assess the image quality, subjective parameters were evaluated using a five-point scale. This scale was applied on overall image quality and contour delineation of critical anatomical structures. All scans were of diagnostic image quality. Bony structures were of good diagnostic image quality in both groups, soft tissues were of sufficient diagnostic image quality in the study group because of a high level of noise. Radiation exposure was very low in both groups, but significantly lower in the study group (CTDI vol 1.2 mGy vs. 4.4 mGy, p < 0.001). Spectral optimization (tin filtration at 100 kV) allows for visualization of the paranasal sinus with sufficient image quality at a very low radiation exposure. • Spectral optimization (tin filtration) is beneficial to low-dose parasinus CT • Tin filtration at 100 kV yields sufficient image quality for pre-operative planning • Diagnostic parasinus CT can be performed with an effective dose <0.05 mSv.
Atmospheric Science Data Center
2017-04-26
... Moderate Resolution Imaging Spectrometer (MODIS) Airborne Simulator (MAS) Data Project Title: MAS ... IDL Code ER2 Flight Tracks Related Data: MAS Additional Info: ER-2 MODIS Airborne Simulator (MAS) Image Gallery: ...
NASA Astrophysics Data System (ADS)
Khobragade, P.; Fan, Jiahua; Rupcich, Franco; Crotty, Dominic J.; Gilat Schmidt, Taly
2016-03-01
This study quantitatively evaluated the performance of the exponential transformation of the free-response operating characteristic curve (EFROC) metric, with the Channelized Hotelling Observer (CHO) as a reference. The CHO has been used for image quality assessment of reconstruction algorithms and imaging systems and often it is applied to study the signal-location-known cases. The CHO also requires a large set of images to estimate the covariance matrix. In terms of clinical applications, this assumption and requirement may be unrealistic. The newly developed location-unknown EFROC detectability metric is estimated from the confidence scores reported by a model observer. Unlike the CHO, EFROC does not require a channelization step and is a non-parametric detectability metric. There are few quantitative studies available on application of the EFROC metric, most of which are based on simulation data. This study investigated the EFROC metric using experimental CT data. A phantom with four low contrast objects: 3mm (14 HU), 5mm (7HU), 7mm (5 HU) and 10 mm (3 HU) was scanned at dose levels ranging from 25 mAs to 270 mAs and reconstructed using filtered backprojection. The area under the curve values for CHO (AUC) and EFROC (AFE) were plotted with respect to different dose levels. The number of images required to estimate the non-parametric AFE metric was calculated for varying tasks and found to be less than the number of images required for parametric CHO estimation. The AFE metric was found to be more sensitive to changes in dose than the CHO metric. This increased sensitivity and the assumption of unknown signal location may be useful for investigating and optimizing CT imaging methods. Future work is required to validate the AFE metric against human observers.
Borgia, R Ezequiel; Gerstein, Maya; Levy, Deborah M; Silverman, Earl D; Hiraki, Linda T
2018-04-01
To describe the features and treatment of macrophage activation syndrome (MAS) in a single-center cohort of patients with childhood-onset systemic lupus erythematosus (SLE), and to compare childhood-onset SLE manifestations and outcomes between those with and those without MAS. We included all patients with childhood-onset SLE followed up at The Hospital for Sick Children from 2002 to 2012, and identified those also diagnosed as having MAS. Demographic, clinical, and laboratory features of MAS and SLE, medication use, hospital and pediatric intensive care unit (PICU) admissions, as well as damage indices and mortality data were extracted from the Lupus database. Student's t-tests and Fisher's exact tests were used to compare continuous and categorical variables, respectively. We calculated incidence rate ratios of hospital and PICU admissions comparing patients with and those without MAS, using Poisson models. Kaplan-Meier survival analysis was used to examine the time to disease damage accrual. Of the 403 patients with childhood-onset SLE, 38 (9%) had MAS. The majority (68%) had concomitant MAS and SLE diagnoses. Fever was the most common MAS clinical feature. The frequency of renal and central nervous system disease, hospital admissions, the average daily dose of steroids, and time to disease damage were similar between those with and those without MAS. We observed a higher mortality rate among those with MAS (5%) than those without MAS (0.2%) (P = 0.02). MAS was most likely to develop concomitantly with childhood-onset SLE diagnosis. The majority of the MAS patients were successfully treated with corticosteroids with no MAS relapses. Although the numbers were small, there was a higher risk of death associated with MAS compared to SLE without MAS. © 2018, American College of Rheumatology.
1985-09-13
MAS Wins Contract to Service Air Force Planes (ANTARA NEWS BULLETIN, 3 Aug 85) Leaders Receive Messages of Thanks From MPR (KPL, 14 Aug 85...Dissolve Batasan ( BUSINESS DAY, 16 Aug 85) 31 Author on ’Quid-Pro-Quo’ in Sabah Claim (Nelly Sindayen; BULLETIN TODAY, 2 Jul 85) 32 Columnist...Exchange ( BUSINESS DAY, 16 Aug 85) 49 Batasan Speaker Yniguez ’Welcomed’ USSR Peace Efforts (Cross-reference) Bigornia Comments on USSR Aid to
Demehri, S; Muhit, A; Zbijewski, W; Stayman, J W; Yorkston, J; Packard, N; Senn, R; Yang, D; Foos, D; Thawait, G K; Fayad, L M; Chhabra, A; Carrino, J A; Siewerdsen, J H
2015-06-01
To assess visualization tasks using cone-beam CT (CBCT) compared to multi-detector CT (MDCT) for musculoskeletal extremity imaging. Ten cadaveric hands and ten knees were examined using a dedicated CBCT prototype and a clinical multi-detector CT using nominal protocols (80 kVp-108mAs for CBCT; 120 kVp- 300 mAs for MDCT). Soft tissue and bone visualization tasks were assessed by four radiologists using five-point satisfaction (for CBCT and MDCT individually) and five-point preference (side-by-side CBCT versus MDCT image quality comparison) rating tests. Ratings were analyzed using Kruskal-Wallis and Wilcoxon signed-rank tests, and observer agreement was assessed using the Kappa-statistic. Knee CBCT images were rated "excellent" or "good" (median scores 5 and 4) for "bone" and "soft tissue" visualization tasks. Hand CBCT images were rated "excellent" or "adequate" (median scores 5 and 3) for "bone" and "soft tissue" visualization tasks. Preference tests rated CBCT equivalent or superior to MDCT for bone visualization and favoured the MDCT for soft tissue visualization tasks. Intraobserver agreement for CBCT satisfaction tests was fair to almost perfect (κ ~ 0.26-0.92), and interobserver agreement was fair to moderate (κ ~ 0.27-0.54). CBCT provided excellent image quality for bone visualization and adequate image quality for soft tissue visualization tasks. • CBCT provided adequate image quality for diagnostic tasks in extremity imaging. • CBCT images were "excellent" for "bone" and "good/adequate" for "soft tissue" visualization tasks. • CBCT image quality was equivalent/superior to MDCT for bone visualization tasks.
Ladomenou, Fani; Carpenter, Ben; Chandra, Sharat; Sedlacek, Petr; Formankova, Renata; Grandage, Vicky; Friswell, Mark; Cant, Andrew J.; Nademi, Zohreh; Slatter, Mary A.; Gennery, Andrew R.; Hambleton, Sophie; Flood, Terence J.; Lucchini, Giovanna; Chiesa, Robert; Rao, Kanchan; Amrolia, Persis J.; Brogan, Paul; Wedderburn, Lucy R.; Glanville, Julie M.; Hough, Rachael; Marsh, Rebecca; Abinun, Mario; Veys, Paul
2018-01-01
Patients with juvenile idiopathic arthritis (JIA) can experience a severe disease course, with progressive destructive polyarthritis refractory to conventional therapy with disease-modifying antirheumatic drugs including biologics, as well as life-threatening complications including macrophage activation syndrome (MAS). Allogeneic hematopoietic stem cell transplantation (allo-HSCT) is a potentially curative immunomodulatory strategy for patients with such refractory disease. We treated 16 patients in 5 transplant centers between 2007 and 2016: 11 children with systemic JIA and 5 with rheumatoid factor–negative polyarticular JIA; all were either refractory to standard therapy, had developed secondary hemophagocytic lymphohistiocytosis/MAS poorly responsive to treatment, or had failed autologous HSCT. All children received reduced toxicity fludarabine-based conditioning regimens and serotherapy with alemtuzumab. Fourteen of 16 patients are alive with a median follow-up of 29 months (range, 2.8-96 months). All patients had hematological recovery. Three patients had grade II-IV acute graft-versus-host disease. The incidence of viral infections after HSCT was high, likely due to the use of alemtuzumab in already heavily immunosuppressed patients. All patients had significant improvement of arthritis, resolution of MAS, and improved quality of life early following allo-HSCT; most importantly, 11 children achieved complete drug-free remission at the last follow-up. Allo-HSCT using alemtuzumab and reduced toxicity conditioning is a promising therapeutic option for patients with JIA refractory to conventional therapy and/or complicated by MAS. Long-term follow-up is required to ascertain whether disease control following HSCT continues indefinitely. PMID:29618462
Improving Scene Classifications with Combined Active/Passive Measurements
NASA Astrophysics Data System (ADS)
Hu, Y.; Rodier, S.; Vaughan, M.; McGill, M.
The uncertainties in cloud and aerosol physical properties derived from passive instruments such as MODIS are not insignificant And the uncertainty increases when the optical depths decrease Lidar observations do much better for the thin clouds and aerosols Unfortunately space-based lidar measurements such as the one onboard CALIPSO satellites are limited to nadir view only and thus have limited spatial coverage To produce climatologically meaningful thin cloud and aerosol data products it is necessary to combine the spatial coverage of MODIS with the highly sensitive CALIPSO lidar measurements Can we improving the quality of cloud and aerosol remote sensing data products by extending the knowledge about thin clouds and aerosols learned from CALIPSO-type of lidar measurements to a larger portion of the off-nadir MODIS-like multi-spectral pixels To answer the question we studied the collocated Cloud Physics Lidar CPL with Modis-Airborne-Simulation MAS observations and established an effective data fusion technique that will be applied in the combined CALIPSO MODIS cloud aerosol product algorithms This technique performs k-mean and Kohonen self-organized map cluster analysis on the entire swath of MAS data as well as on the combined CPL MAS data at the nadir track Interestingly the clusters generated from the two approaches are almost identical It indicates that the MAS multi-spectral data may have already captured most of the cloud and aerosol scene types such as cloud ice water phase multi-layer information aerosols
NASA Astrophysics Data System (ADS)
Alharbi, Samah; Hu, Sijung; Mulvaney, David; Blanos, Panagiotis
2018-02-01
The ability to gather physiological parameters such as heart rate (HR) and oxygen saturation (SpO2%) during physical movement allows to continuously monitor personal health status without disrupt their normal daily activities. Photoplethysmography (PPG) based pulse oximetry and similar principle devices are unable to extract the HR and SpO2% reliably during physical movement due to interference in the signals that arise from motion artefacts (MAs). In this research, a flexible reflectance multi-wavelength optoelectronic patch sensor (OEPS) has been developed to overcome the susceptibility of conventional pulse oximetry readings to MAs. The OEPS incorporates light embittered diodes as illumination sources with four different wavelengths, e.g. green, orange, red, and infrared unlike the conventional pulse oximetry devices that normally measure the skin absorption of only two wavelengths (red and infrared). The additional green and orange wavelengths were found to be distinguish to the absorption of deoxyhemoglobin (RHb) and oxyhemoglobin (HbO2). The reliability of extracting physiological parameters from the green and orange wavelengths is due to absorbed near to the surface of the skin, thereby shortening the optical path and so effectively reducing the influence of physical movements. To compensate of MAs, a three-axis accelerometer was used as a reference with help of adaptive filter to reduce MAs. The experiments were performed using 15 healthy subjects aged 20 to 30. The primary results show that there are no significant difference of heart rate and oxygen saturation measurements between commercial devices and OEPS Green (r=0.992), Orange(r=0.984), Red(r=0.952) and IR(r=0.97) and SpO2% (r = 0.982, p = 0.894).
Stark, Jeffrey G; Engelking, Dorothy; McMahen, Russ; Sikes, Carolyn
2016-09-01
In this pharmacokinetic (PK) study in healthy adults, we sought to: (1) compare the PK properties of a novel amphetamine extended-release orally disintegrating tablet formulation (Adzenys XR-ODT™ [AMP XR-ODT]) to a reference extended-release mixed amphetamine salts (MAS ER) formulation and (2) assess the effect of food on AMP XR-ODT. Forty-two adults were enrolled in a single-dose, open-label, 3-period, 3-treatment, randomized crossover study and received an 18.8-mg dose of AMP XR-ODT (fasted or fed) or equivalent dose (30 mg) of MAS ER (fasted). Plasma samples were analyzed for d-and l-amphetamine. Maximum plasma concentration (Cmax), time to maximum plasma concentration (Tmax), elimination half-life (T1/2), area under the concentration-time curve from time zero to last quantifiable concentration (AUClast), from time zero to infinity (AUCinf), relevant partial AUCs, and weight-normalized clearance (CL/F/kg) were assessed. The PK parameters were compared across treatments using an ANOVA. Safety was also assessed. A total of 39 adults completed this study. The geometric mean ratios (90% confidence interval [CI]) for AMP XR-ODT/MAS ER Cmax, AUC5-last, AUClast, and AUCinf were within 80%-125% for both d-and l-amphetamine. The 90% CIs for AUC0-5 were slightly below the 80%-125% range. When AMP XR-ODT was administered with food, there was a slight decrease in the d-and l-amphetamine Cmax and approximately a 2-hour delay in Tmax. The most common adverse events reported (>5% of participants) were dry mouth, palpitations, nausea, dizziness, headache, anxiety, and nasal congestion. AMP XR-ODT displayed a PK profile similar to MAS ER, and no clinically relevant food effect was observed.
Khunawattanakul, Wanwisa; Puttipipatkhachorn, Satit; Rades, Thomas; Pongjanyakul, Thaned
2008-03-03
Composite dispersions of chitosan (CS), a positively charged polymer, and magnesium aluminum silicate (MAS), a negatively charged clay, were prepared and rheology, flocculate size and zeta potential of the CS-MAS dispersions were investigated. High and low molecular weights of CS (HCS and LCS, respectively) were used in this study. Moreover, the effects of heat treatment at 60 degrees C on the characteristics of the CS-MAS dispersions and the zeta potential of MAS upon addition of CS at different pHs were examined. Incorporation of MAS into CS dispersions caused an increase in viscosity and a shift of CS flow type from Newtonian to pseudoplastic flow with thixotropic properties. Heat treatment brought about a significant decrease in viscosity and hysteresis area of the composite dispersions. Microscopic studies showed that flocculation of MAS occurred after mixing with CS. The size and polydispersity index of the HCS-MAS flocculate were greater than those of the LCS-MAS flocculate. However, a narrower size distribution and the smaller size of the HCS-MAS flocculate were found after heating at 60 degrees C. Zeta potentials of the CS-MAS flocculates were positive and slightly increased with increasing MAS content. In the zeta potential studies, the negative charge of the MAS could be neutralized by the addition of CS. Increasing the pH and molecular weight of CS resulted in higher CS concentrations required to neutralize the charge of MAS. These findings suggest that the electrostatic interaction between CS and MAS caused a change in flow behavior and flocculation of the composite dispersions, depending on the molecular weight of CS. Heat treatment affected the rheological properties and the flocculate size of the composite dispersions. Moreover, pH of medium and molecular weight of CS influence the zeta potential of MAS.
Wakiguchi, Hiroyuki; Hasegawa, Shunji; Hirano, Reiji; Kaneyasu, Hidenobu; Wakabayashi-Takahara, Midori; Ohga, Shouichi
2015-11-18
Macrophage activation syndrome (MAS) is the secondary hemophagocytic lymphohistiocytosis associated with rheumatic diseases. Recently, the different cytokine profiles between systemic juvenile idiopathic arthritis (sJIA)-associated MAS (sJIA-MAS) and juvenile systemic lupus erythematosus (JSLE)-associated MAS (JSLE-MAS) were reported. However, there is little information about juvenile dermatomyositis (JDM)-associated MAS (JDM-MAS). A 4-year-old girl with JDM was hospitalized because of fever, erythema, hepatosplenomegaly, cytopenia, liver dysfunction and coagulopathy. Bone marrow aspiration revealed appreciable numbers of activated and hemophagocytosing macrophages. She was diagnosed as having JDM-MAS complicated with interstitial pneumonia (IP) based on the findings of the elevation of serum Krebs von den Lungen-6 (KL-6) levels and chest computed tomography findings. We analyzed circulating levels of interleukin (IL)-2,4,6,10,18, tumor necrosis factor-α and interferon-γ in the patient. Hypercytokinemia occurred at the diagnosis of MAS and IP, showing with the prominent elevations of IL-6 and IL-18 levels. The cytokine profiles were distinct from those reported in patients with sJIA-MAS or JSLE-MAS. High-dose corticosteroid and cyclosporine therapy led to a drastic improvement of MAS with decreased IL-6 levels. Subsequent cyclophosphamide therapy successfully controlled IP, paralleled with the declining pattern of IL-18 and KL-6 levels. This is the first report to describe a successful treatment and the cytokine profile of JDM-MAS and IP. Serum IL-6 and IL-18 levels may be useful for predicting the disease activity of JDM-MAS and IP, respectively.
New Roles for Medical Assistants in Innovative Primary Care Practices.
Chapman, Susan A; Blash, Lisel K
2017-02-01
To identify and describe new roles for medical assistants (MAs) in innovative care models that improve care while providing training and career advancement opportunities for MAs. Primary data collected at 15 case study sites; 173 key informant interviews and de-identified secondary data on staffing, wages, patient satisfaction, and health outcomes. Researchers used snowball sampling and screening calls to identify 15 organizations using MAs in new roles. Conducted site visits from 2010 to 2012 and updated information in 2014. Thematic analysis explored key topics: factors driving MA role innovation, role description, training required, and wage gains. Categorized outcome data in patient and staff satisfaction, quality of care, and efficiency. New MA roles included health coach, medical scribe, dual role translator, health navigator, panel manager, cross-trained flexible role, and supervisor. Implementation of new roles required extensive training. MA incentives and enhanced compensation varied by role type. New MA roles are part of a larger attempt to reform workflow and relieve primary care providers. Despite some evidence of success, spread has been limited. Key challenges to adoption included leadership and provider resistance to change, cost of additional MA training, and lack of reimbursement for nonbillable services. © Health Research and Educational Trust.
Image quality comparison between single energy and dual energy CT protocols for hepatic imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yao, Yuan, E-mail: yuanyao@stanford.edu; Pelc, Nor
Purpose: Multi-detector computed tomography (MDCT) enables volumetric scans in a single breath hold and is clinically useful for hepatic imaging. For simple tasks, conventional single energy (SE) computed tomography (CT) images acquired at the optimal tube potential are known to have better quality than dual energy (DE) blended images. However, liver imaging is complex and often requires imaging of both structures containing iodinated contrast media, where atomic number differences are the primary contrast mechanism, and other structures, where density differences are the primary contrast mechanism. Hence it is conceivable that the broad spectrum used in a dual energy acquisition maymore » be an advantage. In this work we are interested in comparing these two imaging strategies at equal-dose and more complex settings. Methods: We developed numerical anthropomorphic phantoms to mimic realistic clinical CT scans for medium size and large size patients. MDCT images based on the defined phantoms were simulated using various SE and DE protocols at pre- and post-contrast stages. For SE CT, images from 60 kVp through 140 with 10 kVp steps were considered; for DE CT, both 80/140 and 100/140 kVp scans were simulated and linearly blended at the optimal weights. To make a fair comparison, the mAs of each scan was adjusted to match the reference radiation dose (120 kVp, 200 mAs for medium size patients and 140 kVp, 400 mAs for large size patients). Contrast-to-noise ratio (CNR) of liver against other soft tissues was used to evaluate and compare the SE and DE protocols, and multiple pre- and post-contrasted liver-tissue pairs were used to define a composite CNR. To help validate the simulation results, we conducted a small clinical study. Eighty-five 120 kVp images and 81 blended 80/140 kVp images were collected and compared through both quantitative image quality analysis and an observer study. Results: In the simulation study, we found that the CNR of pre-contrast SE image mostly increased with increasing kVp while for post-contrast imaging 90 kVp or lower yielded higher CNR images, depending on the differential iodine concentration of each tissue. Similar trends were seen in DE blended CNR and those from SE protocols. In the presence of differential iodine concentration (i.e., post-contrast), the CNR curves maximize at lower kVps (80–120), with the peak shifted rightward for larger patients. The combined pre- and post-contrast composite CNR study demonstrated that an optimal SE protocol has better performance than blended DE images, and the optimal tube potential for SE scan is around 90 kVp for a medium size patients and between 90 and 120 kVp for large size patients (although low kVp imaging requires high x-ray tube power to avoid photon starvation). Also, a tin filter added to the high kVp beam is not only beneficial for material decomposition but it improves the CNR of the DE blended images as well. The dose adjusted CNR of the clinical images also showed the same trend and radiologists favored the SE scans over blended DE images. Conclusions: Our simulation showed that an optimized SE protocol produces up to 5% higher CNR for a range of clinical tasks. The clinical study also suggested 120 kVp SE scans have better image quality than blended DE images. Hence, blended DE images do not have a fundamental CNR advantage over optimized SE images.« less
Ryska, Pavel; Kvasnicka, Tomas; Jandura, Jiri; Klzo, Ludovit; Grepl, Jakub; Zizka, Jan
2014-06-01
To compare the effective and eye lens radiation dose in helical MDCT brain examinations using automatic tube current modulation in conjunction with either standard filtered back projection (FBP) technique or iterative reconstruction in image space (IRIS). Of 400 adult brain MDCT examinations, 200 were performed using FBP and 200 using IRIS with the following parameters: tube voltage 120 kV, rotation period 1 second, pitch factor 0.55, automatic tube current modulation in both transverse and longitudinal planes with reference mAs 300 (FBP) and 200 (IRIS). Doses were calculated from CT dose index and dose length product values utilising ImPACT software; the organ dose to the lens was derived from the actual tube current-time product value applied to the lens. Image quality was assessed by two independent readers blinded to the type of image reconstruction technique. The average effective scan dose was 1.47±0.26 mSv (FBP) and 0.98±0.15 mSv (IRIS), respectively (33.3% decrease). The average organ dose to the eye lens decreased from 40.0±3.3 mGy (FBP) to 26.6±2.0 mGy (IRIS, 33.5% decrease). No significant change in diagnostic image quality was noted between IRIS and FBP scans (P=0.17). Iterative reconstruction of cerebral MDCT examinations enables reduction of both effective and organ eye lens dose by one third without signficant loss of image quality.
Silveira, Kátia Daniela; Barroso, Lívia Corrêa; Vieira, Angélica Thomáz; Cisalpino, Daniel; Lima, Cristiano Xavier; Bader, Michael; Arantes, Rosa Maria Esteves; dos Santos, Robson Augusto Souza
2013-01-01
Angiotensin-(1–7) [Ang-(1–7)] is a biologically active heptapeptide that may counterbalance the physiological actions of angiotensin II (Ang II) within the renin-angiotensin system (RAS). Here, we evaluated whether activation of the Mas receptor with the oral agonist, AVE 0991, would have renoprotective effects in a model of adriamycin (ADR)-induced nephropathy. We also evaluated whether the Mas receptor contributed for the protective effects of treatment with AT1 receptor blockers. ADR (10 mg/kg) induced significant renal injury and dysfunction that was maximal at day 14 after injection. Treatment with the Mas receptor agonist AVE 0991 improved renal function parameters, reduced urinary protein loss and attenuated histological changes. Renoprotection was associated with reduction in urinary levels of TGF-β. Similar renoprotection was observed after treatment with the AT1 receptor antagonist, Losartan. AT1 and Mas receptor mRNA levels dropped after ADR administration and treatment with losartan reestablished the expression of Mas receptor and increased the expression of ACE2. ADR-induced nephropathy was similar in wild type (Mas+/+) and Mas knockout (Mas −/−) mice, suggesting there was no endogenous role for Mas receptor activation. However, treatment with Losartan was able to reduce renal injury only in Mas+/+, but not in Mas −/− mice. Therefore, these findings suggest that exogenous activation of the Mas receptor protects from ADR-induced nephropathy and contributes to the beneficial effects of AT1 receptor blockade. Medications which target specifically the ACE2/Ang-(1–7)/Mas axis may offer new therapeutic opportunities to treat human nephropathies. PMID:23762470
Hubble Space Telescope Trigonometric Parallax of Polaris B, Companion of the Nearest Cepheid
NASA Astrophysics Data System (ADS)
Bond, Howard E.; Nelan, Edmund P.; Remage Evans, Nancy; Schaefer, Gail H.; Harmer, Dianne
2018-01-01
Polaris, the nearest and brightest Cepheid, is a potential anchor point for the Leavitt period–luminosity relation. However, its distance is a matter of contention, with recent advocacy for a parallax of ∼10 mas, in contrast with the Hipparcos measurement of 7.54 ± 0.11 mas. We report an independent trigonometric parallax determination, using the Fine Guidance Sensors (FGS) on the Hubble Space Telescope. Polaris itself is too bright for FGS, so we measured its eighth-magnitude companion Polaris B, relative to a network of background reference stars. We converted the FGS relative parallax to absolute, using estimated distances to the reference stars from ground-based photometry and spectral classification. Our result, 6.26 ± 0.24 mas, is even smaller than that found by Hipparcos. We note other objects for which Hipparcos appears to have overestimated parallaxes, including the well-established case of the Pleiades. We consider possible sources of systematic error in the FGS parallax, but find no evidence they are significant. If our “long” distance is correct, the high luminosity of Polaris indicates that it is pulsating in the second overtone of its fundamental mode. Our results raise several puzzles, including a long pulsation period for Polaris compared to second-overtone pulsators in the Magellanic Clouds, and a conflict between the isochrone age of Polaris B (∼2.1 Gyr) and the much younger age of Polaris A. We discuss possibilities that B is not a physical companion of A, in spite of the strong evidence that it is, or that one of the stars is a merger remnant. These issues may be resolved when Gaia provides parallaxes for both stars. Based in part on observations made with the NASA/ESA Hubble Space Telescope, obtained by the Space Telescope Science Institute. STScI is operated by the Association of Universities for Research in Astronomy, Inc., under NASA contract NAS5-26555.
THE POSITION/STRUCTURE STABILITY OF FOUR ICRF2 SOURCES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fomalont, Ed; Johnston, Kenneth; Fey, Alan
2011-03-15
Four close radio sources in the International Celestial Reference Frame (ICRF) catalog were observed using phase referencing with the VLBA at 43, 23, and 8.6 GHz, and with VERA at 23 GHz over a one-year period. The goal was to determine the stability of the radio cores and to assess structure effects associated with positions in the ICRF. Although the four sources were compact at 8.6 GHz, the VLBA images at 43 GHz with 0.3 mas resolution showed that all were composed of several components. A component in each source was identified as the radio core using some or allmore » of the following emission properties: compactness, spectral index, location at the end of the extended emission region, and stationary in the sky. Over the observing period, the relative positions between the four radio cores were constant to 0.02 mas, the phase-referencing positional accuracy obtained at 23 and 43 GHz among the sources, suggesting that once a radio core is identified, it remains stationary in the sky to this accuracy. Other radio components in two of the four sources had detectable motion in the radio jet direction. Comparison of the 23 and 43 GHz VLBA images with the VLBA 8.6 GHz images and the ICRF positions suggests that some ICRF positions are dominated by a moving jet component; hence, they can be displaced up to 0.5 mas from the radio core and may also reflect the motion of the jet component. Future astrometric efforts to determine a more accurate quasar reference frame at 23 and 43 GHz and from the VLBI2010 project are discussed, and supporting VLBA or European VLBI Network observations of ICRF sources at 43 GHz are recommended in order to determine the internal structure of the sources. A future collaboration between the radio (ICRF) and the optical frame of GAIA is discussed.« less
Gaia Data Release 1. Summary of the astrometric, photometric, and survey properties
NASA Astrophysics Data System (ADS)
Gaia Collaboration; Brown, A. G. A.; Vallenari, A.; Prusti, T.; de Bruijne, J. H. J.; Mignard, F.; Drimmel, R.; Babusiaux, C.; Bailer-Jones, C. A. L.; Bastian, U.; Biermann, M.; Evans, D. W.; Eyer, L.; Jansen, F.; Jordi, C.; Katz, D.; Klioner, S. A.; Lammers, U.; Lindegren, L.; Luri, X.; O'Mullane, W.; Panem, C.; Pourbaix, D.; Randich, S.; Sartoretti, P.; Siddiqui, H. I.; Soubiran, C.; Valette, V.; van Leeuwen, F.; Walton, N. A.; Aerts, C.; Arenou, F.; Cropper, M.; Høg, E.; Lattanzi, M. G.; Grebel, E. K.; Holland, A. D.; Huc, C.; Passot, X.; Perryman, M.; Bramante, L.; Cacciari, C.; Castañeda, J.; Chaoul, L.; Cheek, N.; De Angeli, F.; Fabricius, C.; Guerra, R.; Hernández, J.; Jean-Antoine-Piccolo, A.; Masana, E.; Messineo, R.; Mowlavi, N.; Nienartowicz, K.; Ordóñez-Blanco, D.; Panuzzo, P.; Portell, J.; Richards, P. J.; Riello, M.; Seabroke, G. M.; Tanga, P.; Thévenin, F.; Torra, J.; Els, S. G.; Gracia-Abril, G.; Comoretto, G.; Garcia-Reinaldos, M.; Lock, T.; Mercier, E.; Altmann, M.; Andrae, R.; Astraatmadja, T. L.; Bellas-Velidis, I.; Benson, K.; Berthier, J.; Blomme, R.; Busso, G.; Carry, B.; Cellino, A.; Clementini, G.; Cowell, S.; Creevey, O.; Cuypers, J.; Davidson, M.; De Ridder, J.; de Torres, A.; Delchambre, L.; Dell'Oro, A.; Ducourant, C.; Frémat, Y.; García-Torres, M.; Gosset, E.; Halbwachs, J.-L.; Hambly, N. C.; Harrison, D. L.; Hauser, M.; Hestroffer, D.; Hodgkin, S. T.; Huckle, H. E.; Hutton, A.; Jasniewicz, G.; Jordan, S.; Kontizas, M.; Korn, A. J.; Lanzafame, A. C.; Manteiga, M.; Moitinho, A.; Muinonen, K.; Osinde, J.; Pancino, E.; Pauwels, T.; Petit, J.-M.; Recio-Blanco, A.; Robin, A. C.; Sarro, L. M.; Siopis, C.; Smith, M.; Smith, K. W.; Sozzetti, A.; Thuillot, W.; van Reeven, W.; Viala, Y.; Abbas, U.; Abreu Aramburu, A.; Accart, S.; Aguado, J. J.; Allan, P. M.; Allasia, W.; Altavilla, G.; Álvarez, M. A.; Alves, J.; Anderson, R. I.; Andrei, A. H.; Anglada Varela, E.; Antiche, E.; Antoja, T.; Antón, S.; Arcay, B.; Bach, N.; Baker, S. G.; Balaguer-Núñez, L.; Barache, C.; Barata, C.; Barbier, A.; Barblan, F.; Barrado y Navascués, D.; Barros, M.; Barstow, M. A.; Becciani, U.; Bellazzini, M.; Bello García, A.; Belokurov, V.; Bendjoya, P.; Berihuete, A.; Bianchi, L.; Bienaymé, O.; Billebaud, F.; Blagorodnova, N.; Blanco-Cuaresma, S.; Boch, T.; Bombrun, A.; Borrachero, R.; Bouquillon, S.; Bourda, G.; Bouy, H.; Bragaglia, A.; Breddels, M. A.; Brouillet, N.; Brüsemeister, T.; Bucciarelli, B.; Burgess, P.; Burgon, R.; Burlacu, A.; Busonero, D.; Buzzi, R.; Caffau, E.; Cambras, J.; Campbell, H.; Cancelliere, R.; Cantat-Gaudin, T.; Carlucci, T.; Carrasco, J. M.; Castellani, M.; Charlot, P.; Charnas, J.; Chiavassa, A.; Clotet, M.; Cocozza, G.; Collins, R. S.; Costigan, G.; Crifo, F.; Cross, N. J. G.; Crosta, M.; Crowley, C.; Dafonte, C.; Damerdji, Y.; Dapergolas, A.; David, P.; David, M.; De Cat, P.; de Felice, F.; de Laverny, P.; De Luise, F.; De March, R.; de Martino, D.; de Souza, R.; Debosscher, J.; del Pozo, E.; Delbo, M.; Delgado, A.; Delgado, H. E.; Di Matteo, P.; Diakite, S.; Distefano, E.; Dolding, C.; Dos Anjos, S.; Drazinos, P.; Duran, J.; Dzigan, Y.; Edvardsson, B.; Enke, H.; Evans, N. W.; Eynard Bontemps, G.; Fabre, C.; Fabrizio, M.; Faigler, S.; Falcão, A. J.; Farràs Casas, M.; Federici, L.; Fedorets, G.; Fernández-Hernández, J.; Fernique, P.; Fienga, A.; Figueras, F.; Filippi, F.; Findeisen, K.; Fonti, A.; Fouesneau, M.; Fraile, E.; Fraser, M.; Fuchs, J.; Gai, M.; Galleti, S.; Galluccio, L.; Garabato, D.; García-Sedano, F.; Garofalo, A.; Garralda, N.; Gavras, P.; Gerssen, J.; Geyer, R.; Gilmore, G.; Girona, S.; Giuffrida, G.; Gomes, M.; González-Marcos, A.; González-Núñez, J.; González-Vidal, J. J.; Granvik, M.; Guerrier, A.; Guillout, P.; Guiraud, J.; Gúrpide, A.; Gutiérrez-Sánchez, R.; Guy, L. P.; Haigron, R.; Hatzidimitriou, D.; Haywood, M.; Heiter, U.; Helmi, A.; Hobbs, D.; Hofmann, W.; Holl, B.; Holland, G.; Hunt, J. A. S.; Hypki, A.; Icardi, V.; Irwin, M.; Jevardat de Fombelle, G.; Jofré, P.; Jonker, P. G.; Jorissen, A.; Julbe, F.; Karampelas, A.; Kochoska, A.; Kohley, R.; Kolenberg, K.; Kontizas, E.; Koposov, S. E.; Kordopatis, G.; Koubsky, P.; Krone-Martins, A.; Kudryashova, M.; Kull, I.; Bachchan, R. K.; Lacoste-Seris, F.; Lanza, A. F.; Lavigne, J.-B.; Le Poncin-Lafitte, C.; Lebreton, Y.; Lebzelter, T.; Leccia, S.; Leclerc, N.; Lecoeur-Taibi, I.; Lemaitre, V.; Lenhardt, H.; Leroux, F.; Liao, S.; Licata, E.; Lindstrøm, H. E. P.; Lister, T. A.; Livanou, E.; Lobel, A.; Löffler, W.; López, M.; Lorenz, D.; MacDonald, I.; Magalhães Fernandes, T.; Managau, S.; Mann, R. G.; Mantelet, G.; Marchal, O.; Marchant, J. M.; Marconi, M.; Marinoni, S.; Marrese, P. M.; Marschalkó, G.; Marshall, D. J.; Martín-Fleitas, J. M.; Martino, M.; Mary, N.; Matijevič, G.; Mazeh, T.; McMillan, P. J.; Messina, S.; Michalik, D.; Millar, N. R.; Miranda, B. M. H.; Molina, D.; Molinaro, R.; Molinaro, M.; Molnár, L.; Moniez, M.; Montegriffo, P.; Mor, R.; Mora, A.; Morbidelli, R.; Morel, T.; Morgenthaler, S.; Morris, D.; Mulone, A. F.; Muraveva, T.; Musella, I.; Narbonne, J.; Nelemans, G.; Nicastro, L.; Noval, L.; Ordénovic, C.; Ordieres-Meré, J.; Osborne, P.; Pagani, C.; Pagano, I.; Pailler, F.; Palacin, H.; Palaversa, L.; Parsons, P.; Pecoraro, M.; Pedrosa, R.; Pentikäinen, H.; Pichon, B.; Piersimoni, A. M.; Pineau, F.-X.; Plachy, E.; Plum, G.; Poujoulet, E.; Prša, A.; Pulone, L.; Ragaini, S.; Rago, S.; Rambaux, N.; Ramos-Lerate, M.; Ranalli, P.; Rauw, G.; Read, A.; Regibo, S.; Reylé, C.; Ribeiro, R. A.; Rimoldini, L.; Ripepi, V.; Riva, A.; Rixon, G.; Roelens, M.; Romero-Gómez, M.; Rowell, N.; Royer, F.; Ruiz-Dern, L.; Sadowski, G.; Sagristà Sellés, T.; Sahlmann, J.; Salgado, J.; Salguero, E.; Sarasso, M.; Savietto, H.; Schultheis, M.; Sciacca, E.; Segol, M.; Segovia, J. C.; Segransan, D.; Shih, I.-C.; Smareglia, R.; Smart, R. L.; Solano, E.; Solitro, F.; Sordo, R.; Soria Nieto, S.; Souchay, J.; Spagna, A.; Spoto, F.; Stampa, U.; Steele, I. A.; Steidelmüller, H.; Stephenson, C. A.; Stoev, H.; Suess, F. F.; Süveges, M.; Surdej, J.; Szabados, L.; Szegedi-Elek, E.; Tapiador, D.; Taris, F.; Tauran, G.; Taylor, M. B.; Teixeira, R.; Terrett, D.; Tingley, B.; Trager, S. C.; Turon, C.; Ulla, A.; Utrilla, E.; Valentini, G.; van Elteren, A.; Van Hemelryck, E.; van Leeuwen, M.; Varadi, M.; Vecchiato, A.; Veljanoski, J.; Via, T.; Vicente, D.; Vogt, S.; Voss, H.; Votruba, V.; Voutsinas, S.; Walmsley, G.; Weiler, M.; Weingrill, K.; Wevers, T.; Wyrzykowski, Ł.; Yoldas, A.; Žerjal, M.; Zucker, S.; Zurbach, C.; Zwitter, T.; Alecu, A.; Allen, M.; Allende Prieto, C.; Amorim, A.; Anglada-Escudé, G.; Arsenijevic, V.; Azaz, S.; Balm, P.; Beck, M.; Bernstein, H.-H.; Bigot, L.; Bijaoui, A.; Blasco, C.; Bonfigli, M.; Bono, G.; Boudreault, S.; Bressan, A.; Brown, S.; Brunet, P.-M.; Bunclark, P.; Buonanno, R.; Butkevich, A. G.; Carret, C.; Carrion, C.; Chemin, L.; Chéreau, F.; Corcione, L.; Darmigny, E.; de Boer, K. S.; de Teodoro, P.; de Zeeuw, P. T.; Delle Luche, C.; Domingues, C. D.; Dubath, P.; Fodor, F.; Frézouls, B.; Fries, A.; Fustes, D.; Fyfe, D.; Gallardo, E.; Gallegos, J.; Gardiol, D.; Gebran, M.; Gomboc, A.; Gómez, A.; Grux, E.; Gueguen, A.; Heyrovsky, A.; Hoar, J.; Iannicola, G.; Isasi Parache, Y.; Janotto, A.-M.; Joliet, E.; Jonckheere, A.; Keil, R.; Kim, D.-W.; Klagyivik, P.; Klar, J.; Knude, J.; Kochukhov, O.; Kolka, I.; Kos, J.; Kutka, A.; Lainey, V.; LeBouquin, D.; Liu, C.; Loreggia, D.; Makarov, V. V.; Marseille, M. G.; Martayan, C.; Martinez-Rubi, O.; Massart, B.; Meynadier, F.; Mignot, S.; Munari, U.; Nguyen, A.-T.; Nordlander, T.; Ocvirk, P.; O'Flaherty, K. S.; Olias Sanz, A.; Ortiz, P.; Osorio, J.; Oszkiewicz, D.; Ouzounis, A.; Palmer, M.; Park, P.; Pasquato, E.; Peltzer, C.; Peralta, J.; Péturaud, F.; Pieniluoma, T.; Pigozzi, E.; Poels, J.; Prat, G.; Prod'homme, T.; Raison, F.; Rebordao, J. M.; Risquez, D.; Rocca-Volmerange, B.; Rosen, S.; Ruiz-Fuertes, M. I.; Russo, F.; Sembay, S.; Serraller Vizcaino, I.; Short, A.; Siebert, A.; Silva, H.; Sinachopoulos, D.; Slezak, E.; Soffel, M.; Sosnowska, D.; Straižys, V.; ter Linden, M.; Terrell, D.; Theil, S.; Tiede, C.; Troisi, L.; Tsalmantza, P.; Tur, D.; Vaccari, M.; Vachier, F.; Valles, P.; Van Hamme, W.; Veltz, L.; Virtanen, J.; Wallut, J.-M.; Wichmann, R.; Wilkinson, M. I.; Ziaeepour, H.; Zschocke, S.
2016-11-01
Context. At about 1000 days after the launch of Gaia we present the first Gaia data release, Gaia DR1, consisting of astrometry and photometry for over 1 billion sources brighter than magnitude 20.7. Aims: A summary of Gaia DR1 is presented along with illustrations of the scientific quality of the data, followed by a discussion of the limitations due to the preliminary nature of this release. Methods: The raw data collected by Gaia during the first 14 months of the mission have been processed by the Gaia Data Processing and Analysis Consortium (DPAC) and turned into an astrometric and photometric catalogue. Results: Gaia DR1 consists of three components: a primary astrometric data set which contains the positions, parallaxes, and mean proper motions for about 2 million of the brightest stars in common with the Hipparcos and Tycho-2 catalogues - a realisation of the Tycho-Gaia Astrometric Solution (TGAS) - and a secondary astrometric data set containing the positions for an additional 1.1 billion sources. The second component is the photometric data set, consisting of mean G-band magnitudes for all sources. The G-band light curves and the characteristics of 3000 Cepheid and RR Lyrae stars, observed at high cadence around the south ecliptic pole, form the third component. For the primary astrometric data set the typical uncertainty is about 0.3 mas for the positions and parallaxes, and about 1 mas yr-1 for the proper motions. A systematic component of 0.3 mas should be added to the parallax uncertainties. For the subset of 94 000 Hipparcos stars in the primary data set, the proper motions are much more precise at about 0.06 mas yr-1. For the secondary astrometric data set, the typical uncertainty of the positions is 10 mas. The median uncertainties on the mean G-band magnitudes range from the mmag level to 0.03 mag over the magnitude range 5 to 20.7. Conclusions: Gaia DR1 is an important milestone ahead of the next Gaia data release, which will feature five-parameter astrometry for all sources. Extensive validation shows that Gaia DR1 represents a major advance in the mapping of the heavens and the availability of basic stellar data that underpin observational astrophysics. Nevertheless, the very preliminary nature of this first Gaia data release does lead to a number of important limitations to the data quality which should be carefully considered before drawing conclusions from the data.
A Vision in Jeopardy: Royal Navy Maritime Autonomous Systems (MAS)
2017-03-31
Chapter 6 will propose a new MAS vision for the RN. However, before doing so, a fresh look at the problem is required. Consensus of the Problem, Not the... assessment , the RN has failed to deliver any sustainable MAS operational capability. A vision for MAS finally materialized in 2014. Yet, the vision...continuous investment and assessment , the RN has failed to deliver any sustainable MAS operational capability. A vision for MAS finally materialized in
Chowdhury, Muhammad E H; Mullinger, Karen J; Glover, Paul; Bowtell, Richard
2014-01-01
Large artefacts compromise EEG data quality during simultaneous fMRI. These artefact voltages pose heavy demands on the bandwidth and dynamic range of EEG amplifiers and mean that even small fractional variations in the artefact voltages give rise to significant residual artefacts after average artefact subtraction. Any intrinsic reduction in the magnitude of the artefacts would be highly advantageous, allowing data with a higher bandwidth to be acquired without amplifier saturation, as well as reducing the residual artefacts that can easily swamp signals from brain activity measured using current methods. Since these problems currently limit the utility of simultaneous EEG-fMRI, new approaches for reducing the magnitude and variability of the artefacts are required. One such approach is the use of an EEG cap that incorporates electrodes embedded in a reference layer that has similar conductivity to tissue and is electrically isolated from the scalp. With this arrangement, the artefact voltages produced on the reference layer leads by time-varying field gradients, cardiac pulsation and subject movement are similar to those induced in the scalp leads, but neuronal signals are not detected in the reference layer. Taking the difference of the voltages in the reference and scalp channels will therefore reduce the artefacts, without affecting sensitivity to neuronal signals. Here, we test this approach by using a simple experimental realisation of the reference layer to investigate the artefacts induced on the leads attached to the reference layer and scalp and to evaluate the degree of artefact attenuation that can be achieved via reference layer artefact subtraction (RLAS). Through a series of experiments on phantoms and human subjects, we show that RLAS significantly reduces the gradient (GA), pulse (PA) and motion (MA) artefacts, while allowing accurate recording of neuronal signals. The results indicate that RLAS generally outperforms AAS when motion is present in the removal of the GA and PA, while the combination of AAS and RLAS always produces higher artefact attenuation than AAS. Additionally, we demonstrate that RLAS greatly attenuates the unpredictable and highly variable MAs that are very hard to remove using post-processing methods. © 2013. Published by Elsevier Inc. All rights reserved.
MAS1 Receptor Trafficking Involves ERK1/2 Activation Through a β-Arrestin2-Dependent Pathway.
Cerniello, Flavia M; Carretero, Oscar A; Longo Carbajosa, Nadia A; Cerrato, Bruno D; Santos, Robson A; Grecco, Hernán E; Gironacci, Mariela M
2017-11-01
The MAS1 receptor (R) exerts protective effects in the brain, heart, vessels, and kidney. R trafficking plays a critical function in signal termination and propagation and in R resensitization. We examined MAS1R internalization and trafficking on agonist stimulation and the role of β-arrestin2 in the activation of ERK1/2 (extracellular signal-regulated kinase 1/2) and Akt after MAS1R stimulation. Human embryonic kidney 293T cells were transfected with the coding sequence for MAS1R-YFP (MAS1R fused to yellow fluorescent protein). MAS1R internalization was evaluated by measuring the MAS1R present in the plasma membrane after agonist stimulation using a ligand-binding assay. MAS1R trafficking was evaluated by its colocalization with trafficking markers. MAS1R internalization was blocked in the presence of shRNAcaveolin-1 and with dominant negatives for Eps15 (a protein involved in endocytosed Rs by clathrin-coated pits) and for dynamin. After stimulation, MAS1R colocalized with Rab11-a slow recycling vesicle marker-and not with Rab4-a fast recycling vesicle marker-or LysoTracker-a lysosome marker. Cells transfected with MAS1R showed an increase in Akt and ERK1/2 activation on angiotensin-(1-7) stimulation, which was blocked when the clathrin-coated pits pathway was blocked. Suppression of β-arrestin2 by shRNA reduced the angiotensin-(1-7)-induced ERK1/2 activation, whereas Akt activation was not modified. We conclude that on agonist stimulation, MAS1R is internalized through clathrin-coated pits and caveolae in a dynamin-dependent manner and is then slowly recycled back to the plasma membrane. MAS1R induced Akt and ERK1/2 activation from early endosomes, and the activation of ERK1/2 was mediated by β-arrestin2. Thus, MAS1R activity and density may be tightly controlled by the cell. © 2017 American Heart Association, Inc.
Ferro, Monica; Castiglione, Franca; Punta, Carlo; Melone, Lucio; Panzeri, Walter; Rossi, Barbara; Trotta, Francesco; Mele, Andrea
2016-08-15
The chemical cross-linking of β-cyclodextrin (β-CD) with ethylenediaminetetraacetic dianhydride (EDTA) led to branched polymers referred to as cyclodextrin nanosponges (CDNSEDTA). Two different preparations are described with 1:4 and 1:8 CD-EDTA molar ratios. The corresponding cross-linked polymers were contacted with 0.27 M aqueous solution of ibuprofen sodium salt (IP) leading to homogeneous, colorless, drug loaded hydrogels. The systems were characterized by high resolution magic angle spinning (HR-MAS) NMR spectroscopy. Pulsed field gradient spin echo (PGSE) NMR spectroscopy was used to determine the mean square displacement (MSD) of IP inside the polymeric gel at different observation times td. The data were further processed in order to study the time dependence of MSD: MSD = f(td). The proposed methodology is useful to characterize the different diffusion regimes that, in principle, the solute may experience inside the hydrogel, namely normal or anomalous diffusion. The full protocols including the polymer preparation and purification, the obtainment of drug-loaded hydrogels, the NMR sample preparation, the measurement of MSD by HR-MAS NMR spectroscopy and the final data processing to achieve the time dependence of MSD are here reported and discussed. The presented experiments represent a paradigmatic case and the data are discussed in terms of innovative approach to the characterization of the transport properties of an encapsulated guest within a polymeric host of potential application for drug delivery.
NASA Astrophysics Data System (ADS)
Karovicova, I.; White, T. R.; Nordlander, T.; Lind, K.; Casagrande, L.; Ireland, M. J.; Huber, D.; Creevey, O.; Mourard, D.; Schaefer, G. H.; Gilmore, G.; Chiavassa, A.; Wittkowski, M.; Jofré, P.; Heiter, U.; Thévenin, F.; Asplund, M.
2018-03-01
Large stellar surveys of the Milky Way require validation with reference to a set of `benchmark' stars whose fundamental properties are well determined. For metal-poor benchmark stars, disagreement between spectroscopic and interferometric effective temperatures has called the reliability of the temperature scale into question. We present new interferometric measurements of three metal-poor benchmark stars, HD 140283, HD 122563, and HD 103095, from which we determine their effective temperatures. The angular sizes of all the stars were determined from observations with the PAVO beam combiner at visible wavelengths at the CHARA array, with additional observations of HD 103095 made with the VEGA instrument, also at the CHARA array. Together with photometrically derived bolometric fluxes, the angular diameters give a direct measurement of the effective temperature. For HD 140283, we find θLD = 0.324 ± 0.005 mas, Teff = 5787 ± 48 K; for HD 122563, θLD = 0.926 ± 0.011 mas, Teff = 4636 ± 37 K; and for HD 103095, θLD = 0.595 ± 0.007 mas, Teff = 5140 ± 49 K. Our temperatures for HD 140283 and HD 103095 are hotter than the previous interferometric measurements by 253 and 322 K, respectively. We find good agreement between our temperatures and recent spectroscopic and photometric estimates. We conclude some previous interferometric measurements have been affected by systematic uncertainties larger than their quoted errors.
Suntharalingam, Saravanabavaan; Mikat, Christian; Wetter, Axel; Guberina, Nika; Salem, Ahmed; Heil, Philipp; Forsting, Michael; Nassenstein, Kai
2018-06-01
The aim of this study was to investigate the radiation dose and image quality of a whole-body low-dose CT (WBLDCT) using spectral shaping at 100 kV (Sn 100 kV) for the assessment of osteolytic lesions in patients with multiple myeloma. Thirty consecutive patients were retrospectively selected, who underwent a WBLDCT on a third-generation dual-source CT (DSCT) (Sn 100 kV, ref. mAs: 130). They were matched with patients, who were examined on a second-generation DSCT with a standard low-dose protocol (100 kV, ref. mAs: 111). Objective and subjective image quality, radiation exposure as well as the frequency of osteolytic lesions were evaluated. All scans were of diagnostic image quality. Subjective overall image quality was significantly higher in the study group (p = 0.0003). Objective image analysis revealed that signal intensities, signal-to-noise ratio and contrast-to-noise ratio of the bony structures were equal or significantly higher in the control group. There was no significant difference in the frequency of osteolytic lesions (p = 0.259). The median effective dose of the study protocol was significantly lower (1.45 mSv vs. 5.65 mSv; p < 0.0001). WBLDCT with Sn 100 kV can obtain sufficient image quality for the depiction of osteolytic lesions while reducing the radiation dose by approximately 74%. • Spectral shaping using tin filtration is beneficial for whole-body low-dose CT • Sn 100 kV yields sufficient image quality for depiction of osteolytic lesions • Whole-body low-dose CT can be performed with a median dose of 1.5 mSv.
Magic angle spinning NMR with metallized rotors as cylindrical microwave resonators.
Scott, Faith J; Sesti, Erika L; Choi, Eric J; Laut, Alexander J; Sirigiri, Jagadishwar R; Barnes, Alexander B
2018-04-19
We introduce a novel design for millimeter wave electromagnetic structures within magic angle spinning (MAS) rotors. In this demonstration, a copper coating is vacuum deposited onto the outside surface of a sapphire rotor at a thickness of 50 nm. This thickness is sufficient to reflect 197-GHz microwaves, yet not too thick as to interfere with radiofrequency fields at 300 MHz or prevent sample spinning due to eddy currents. Electromagnetic simulations of an idealized rotor geometry show a microwave quality factor of 148. MAS experiments with sample rotation frequencies of ω r /2π = 5.4 kHz demonstrate that the drag force due to eddy currents within the copper does not prevent sample spinning. Spectra of sodium acetate show resolved 13 C J-couplings of 60 Hz and no appreciable broadening between coated and uncoated sapphire rotors, demonstrating that the copper coating does not prevent shimming and high-resolution nuclear magnetic resonance spectroscopy. Additionally, 13 C Rabi nutation curves of ω 1 /2π = 103 kHz for both coated and uncoated rotors indicate no detrimental impact of the copper coating on radio frequency coupling of the nuclear spins to the sample coil. We present this metal coated rotor as a first step towards an MAS resonator. MAS resonators are expected to have a significant impact on developments in electron decoupling, pulsed dynamic nuclear polarization (DNP), room temperature DNP, DNP with low-power microwave sources, and electron paramagnetic resonance detection. Copyright © 2018 John Wiley & Sons, Ltd.
Kurasawa, Hisashi; Hayashi, Katsuyoshi; Fujino, Akinori; Takasugi, Koichi; Haga, Tsuneyuki; Waki, Kayo; Noguchi, Takashi; Ohe, Kazuhiko
2016-05-01
About 10% of patients with diabetes discontinue treatment, resulting in the progression of diabetes-related complications and reduced quality of life. The objective was to predict a missed clinical appointment (MA), which can lead to discontinued treatment for diabetes patients. A machine-learning algorithm was used to build a logistic regression model for MA predictions, with L2-norm regularization used to avoid over-fitting and 10-fold cross validation used to evaluate prediction performance. Data associated with patient MAs were extracted from electronic medical records and classified into two groups: one related to patients' clinical condition (X1) and the other related to previous findings (X2). The records used were those of the University of Tokyo Hospital, and they included the history of 16 026 clinical appointments scheduled by 879 patients whose initial clinical visit had been made after January 1, 2004, who had diagnostic codes indicating diabetes, and whose HbA1c had been tested within 3 months after their initial visit. Records between April 1, 2011, and June 30, 2014, were inspected for a history of MAs. The best predictor of MAs proved to be X1 + X2 (AUC = 0.958); precision and recall rates were, respectively, 0.757 and 0.659. Among all the appointment data, the day of the week when an appointment was made was most strongly associated with MA predictions (weight = 2.22). Our findings may provide information to help clinicians make timely interventions to avoid MAs. © 2015 Diabetes Technology Society.
Guo, Peipei; Gao, Fuqiang; Zhao, Tingting; Sun, Wei; Wang, Bailiang; Li, Zirong
2017-11-01
Spasticity is a common and serious complication following a stroke, and many clinical research have been conducted to evaluate the effect of extracorporeal shock wave therapy (ESWT) on muscle spasticity in poststroke patients. This meta-analysis aimed to evaluate the therapeutic effect on decreasing spasticity caused by a stroke immediately and 4 weeks after the application of shock wave therapy. We searched PubMed, Embase, Web of Science, and Cochrane Library databases for relevant studies through November 2016 using the following item: (Hypertonia OR Spasticity) and (Shock Wave or ESWT) and (Stroke). The outcomes were evaluated by Modified Ashworth Scale (MAS) grades and pooled by Stata 12.0 (Stata Corp, College Station, TX, USA). Six studies consisting of 9 groups were included in this meta-analysis. The MAS grades immediately after ESWT were significantly improved compared with the baseline values (standardized mean difference [SMD], -1.57; 95% confidence intervals [CIs], -2.20, -.94). Similarly, the MAS grades judged at 4 weeks after ESWT were also showed to be significantly lower than the baseline values (SMD, -1.93; 95% CIs, -2.71, -1.15). ESWT for the spasticity of patients after a stroke is effective, as measured by MAS grades. Moreover, no serious side effects were observed in any patients after shock wave therapy. Nevertheless, our current study with some limitations such as the limited sample size only provided limited quality of evidence; confirmation from a further systematic review or meta-analysis with large-scale, well-designed randomized control trials is required. Copyright © 2017. Published by Elsevier Inc.
Kurasawa, Hisashi; Hayashi, Katsuyoshi; Fujino, Akinori; Takasugi, Koichi; Haga, Tsuneyuki; Waki, Kayo; Noguchi, Takashi; Ohe, Kazuhiko
2015-01-01
Background: About 10% of patients with diabetes discontinue treatment, resulting in the progression of diabetes-related complications and reduced quality of life. Objective: The objective was to predict a missed clinical appointment (MA), which can lead to discontinued treatment for diabetes patients. Methods: A machine-learning algorithm was used to build a logistic regression model for MA predictions, with L2-norm regularization used to avoid over-fitting and 10-fold cross validation used to evaluate prediction performance. Data associated with patient MAs were extracted from electronic medical records and classified into two groups: one related to patients’ clinical condition (X1) and the other related to previous findings (X2). The records used were those of the University of Tokyo Hospital, and they included the history of 16 026 clinical appointments scheduled by 879 patients whose initial clinical visit had been made after January 1, 2004, who had diagnostic codes indicating diabetes, and whose HbA1c had been tested within 3 months after their initial visit. Records between April 1, 2011, and June 30, 2014, were inspected for a history of MAs. Results: The best predictor of MAs proved to be X1 + X2 (AUC = 0.958); precision and recall rates were, respectively, 0.757 and 0.659. Among all the appointment data, the day of the week when an appointment was made was most strongly associated with MA predictions (weight = 2.22). Conclusions: Our findings may provide information to help clinicians make timely interventions to avoid MAs. PMID:26555782
Cardiac Magnetic Resonance Imaging for the Diagnosis of Coronary Artery Disease
2010-01-01
Executive Summary In July 2009, the Medical Advisory Secretariat (MAS) began work on Non-Invasive Cardiac Imaging Technologies for the Diagnosis of Coronary Artery Disease (CAD), an evidence-based review of the literature surrounding different cardiac imaging modalities to ensure that appropriate technologies are accessed by patients suspected of having CAD. This project came about when the Health Services Branch at the Ministry of Health and Long-Term Care asked MAS to provide an evidentiary platform on effectiveness and cost-effectiveness of non-invasive cardiac imaging modalities. After an initial review of the strategy and consultation with experts, MAS identified five key non-invasive cardiac imaging technologies for the diagnosis of CAD. Evidence-based analyses have been prepared for each of these five imaging modalities: cardiac magnetic resonance imaging, single photon emission computed tomography, 64-slice computed tomographic angiography, stress echocardiography, and stress echocardiography with contrast. For each technology, an economic analysis was also completed (where appropriate). A summary decision analytic model was then developed to encapsulate the data from each of these reports (available on the OHTAC and MAS website). The Non-Invasive Cardiac Imaging Technologies for the Diagnosis of Coronary Artery Disease series is made up of the following reports, which can be publicly accessed at the MAS website at: www.health.gov.on.ca/mas or at www.health.gov.on.ca/english/providers/program/mas/mas_about.html Single Photon Emission Computed Tomography for the Diagnosis of Coronary Artery Disease: An Evidence-Based Analysis Stress Echocardiography for the Diagnosis of Coronary Artery Disease: An Evidence-Based Analysis Stress Echocardiography with Contrast for the Diagnosis of Coronary Artery Disease: An Evidence-Based Analysis 64-Slice Computed Tomographic Angiography for the Diagnosis of Coronary Artery Disease: An Evidence-Based Analysis Cardiac Magnetic Resonance Imaging for the Diagnosis of Coronary Artery Disease: An Evidence-Based Analysis Pease note that two related evidence-based analyses of non-invasive cardiac imaging technologies for the assessment of myocardial viability are also available on the MAS website: Positron Emission Tomography for the Assessment of Myocardial Viability: An Evidence-Based Analysis Magnetic Resonance Imaging for the Assessment of Myocardial Viability: an Evidence-Based Analysis The Toronto Health Economics and Technology Assessment Collaborative has also produced an associated economic report entitled: The Relative Cost-effectiveness of Five Non-invasive Cardiac Imaging Technologies for Diagnosing Coronary Artery Disease in Ontario [Internet]. Available from: http://theta.utoronto.ca/reports/?id=7 Objective The objective of this analysis was to determine the diagnostic accuracy of cardiac magnetic resonance imaging (MRI) for the diagnosis of patients with known/suspected coronary artery disease (CAD) compared to coronary angiography. Cardiac MRI Stress cardiac MRI is a non-invasive, x-ray free imaging technique that takes approximately 30 to 45 minutes to complete and can be performed using to two different methods, a) perfusion imaging following a first pass of an intravenous bolus of gadolinium contrast, or b) wall motion imaging. Stress is induced pharmacologically with either dobutamine, dipyridamole, or adenosine, as physical exercise is difficult to perform within the magnet bore and often induces motion artifacts. Alternatives to stress cardiac perfusion MRI include stress single-photon emission computed tomography (SPECT) and stress echocardiography (ECHO). The advantage of cardiac MRI is that it does not pose the radiation burden associated with SPECT. During the same sitting, cardiac MRI can also assess left and right ventricular dimensions, viability, and cardiac mass. It may also mitigate the need for invasive diagnostic coronary angiography in patients with intermediate risk factors for CAD. Evidence-Based Analysis Literature Search A literature search was performed on October 9, 2009 using OVID MEDLINE, MEDLINE In-Process and Other Non-Indexed Citations, EMBASE, the Cumulative Index to Nursing & Allied Health Literature (CINAHL), the Cochrane Library, and the International Agency for Health Technology Assessment (INAHTA) for studies published from January 1, 2005 to October 9, 2008. Abstracts were reviewed by a single reviewer and, for those studies meeting the eligibility criteria, full-text articles were obtained. Reference lists were also examined for any relevant studies not identified through the search. Articles with unknown eligibility were reviewed with a second clinical epidemiologist and then a group of epidemiologists until consensus was established. The quality of evidence was assessed as high, moderate, low or very low according to GRADE methodology. Given the large amount of clinical heterogeneity of the articles meeting the inclusion criteria, as well as suggestions from an Expert Advisory Panel Meeting held on October 5, 2009, the inclusion criteria were revised to examine the effectiveness of cardiac MRI for the detection of CAD. Inclusion Criteria Exclusion Criteria Heath technology assessments, systematic reviews, randomized controlled trials, observational studies ≥20 adult patients enrolled. Published 2004-2009 Licensed by Health Canada For diagnosis of CAD: Reference standard is coronary angiography Significant CAD defined as ≥ 50% coronary stenosis Patients with suspected or known CAD Reported results by patient, not segment Non-English studies Grey literature Planar imaging MUGA Patients with recent MI (i.e., within 1 month) Patients with non-ischemic heart disease Studies done exclusively in special populations (e.g., women, diabetics) Outcomes of Interest Sensitivity and specificity Area under the curve (AUC) Diagnostic odds ratio (DOR) Summary of Findings Stress cardiac MRI using perfusion analysis yielded a pooled sensitivity of 0.91 (95% CI: 0.89 to 0.92) and specificity of 0.79 (95% CI: 0.76 to 0.82) for the detection of CAD. Stress cardiac MRI using wall motion analysis yielded a pooled sensitivity of 0.81 (95% CI: 0.77 to 0.84) and specificity of 0.85 (95% CI: 0.81 to 0.89) for the detection of CAD. Based on DORs, there was no significant difference between pooled stress cardiac MRI using perfusion analysis and pooled stress cardiac MRI using wall motion analysis (P=0.26) for the detection of CAD. Pooled subgroup analysis of stress cardiac MRI using perfusion analysis showed no significant difference in the DORs between 1.5T and 3T MRI (P=0.72) for the detection of CAD. One study (N=60) was identified that examined stress cardiac MRI using wall motion analysis with a 3T MRI. The sensitivity and specificity of 3T MRI were 0.64 (95% CI: 0.44 to 0.81) and 1.00 (95% CI: 0.89 to 1.00), respectively, for the detection of CAD. The effectiveness of stress cardiac MRI for the detection of CAD in unstable patients with acute coronary syndrome was reported in only one study (N=35). Using perfusion analysis, the sensitivity and specificity were 0.72 (95% CI: 0.53 to 0.87) and 1.00 (95% CI: 0.54 to 1.00), respectively, for the detection of CAD. Ontario Health System Impact Analysis According to an expert consultant, in Ontario: Stress first pass perfusion is currently performed in small numbers in London (London Health Sciences Centre) and Toronto (University Health Network at the Toronto General Hospital site and Sunnybrook Health Sciences Centre). Stress wall motion is only performed as part of research protocols and not very often. Cardiac MRI machines use 1.5T almost exclusively, with 3T used in research for first pass perfusion. On November 25 2009, the Cardiac Imaging Expert Advisory Panel met and made the following comments about stress cardiac MRI for perfusion analysis: Accessibility to cardiac MRI is limited and generally used to assess structural abnormalities. Most MRIs in Ontario are already in 24–hour, constant use and it would thus be difficult to add cardiac MRI for CAD diagnosis as an additional indication. The performance of cardiac MRI for the diagnosis of CAD can be technically challenging. GRADE Quality of Evidence for Cardiac MRI in the Diagnosis of CAD The quality of the body of evidence was assessed according to the GRADE Working Group criteria for diagnostic tests. For perfusion analysis, the overall quality was determined to be low and for wall motion analysis the overall quality was very low. PMID:23074389
Adler, Lenard A; Lynch, Lauren R; Shaw, David M; Wallace, Samantha P; Ciranni, Michael A; Briggie, Alexis M; Kulaga, Agatha; O'Donnell, Katherine E; Faraone, Stephen V
2011-09-01
The study objectives were to 1) evaluate medication adherence for adults with attention-deficit/hyperactivity disorder (ADHD) treated with 3 times daily (TID) mixed amphetamine salts immediate release (MAS IR) versus once-daily (qAM) MAS extended release (MAS XR) in a randomized, crossover study; and 2) to examine the associations between adherence and efficacy for MAS IR and MAS XR. Sixty-two adults with ADHD were enrolled and 49 completed the study. The treatment condition order (TID-qAM or qAM-TID) was counterbalanced across participants, with an intervening washout period of ≥ 7 days. Adherence was assessed via 3 measures: 1) self-report, 2) pill count, and 3) the Medication Event Monitoring System (MEMS(®)). The primary efficacy measure was the ADHD Rating Scale (ADHD-RS); secondary measures included the Time-Sensitive ADHD Symptom Scale (TASS) and Clinical Global Impressions-Severity of Illness (CGI-S) scale. Adherence to treatment as measured by self-report and pill count was not significantly different between MAS XR and MAS IR. Adherence was significantly better for MAS XR than MAS IR for all of the MEMS(®) measures. The mean change in ADHD-RS, TASS, and CGI-S scores at endpoint was significantly improved for both MAS IR and MAS XR and did not differ significantly between groups. There was not a significant adherence by efficacy interaction. Adults with ADHD adhered equally well with MAS IR as with MAS XR when assessed by pill count and self-report, but not by the MEMS(®) measures. Both treatments significantly reduced ADHD symptoms, and efficacy was not significantly different between groups. Adherence was not associated with treatment outcome.
Abbas, Ghulam; Hameed, Amjad; Rizwan, Muhammad; Ahsan, Muhammad; Asghar, Muhammad J; Iqbal, Nayyer
2015-01-01
Molecular confirmation of interspecific recombinants is essential to overcome the issues like self-pollination, environmental influence, and inadequacy of morphological characteristics during interspecific hybridization. The present study was conducted for genetic confirmation of mungbean (female) and mashbean (male) interspecific crosses using molecular markers. Initially, polymorphic random amplified polymorphic DNA (RAPD), universal rice primers (URP), and simple sequence repeats (SSR) markers differentiating parent genotypes were identified. Recombination in hybrids was confirmed using these polymorphic DNA markers. The NM 2006 × Mash 88 was most successful interspecific cross. Most of true recombinants confirmed by molecular markers were from this cross combination. SSR markers were efficient in detecting genetic variability and recombination with reference to specific chromosomes and particular loci. SSR (RIS) and RAPD identified variability dispersed throughout the genome. In conclusion, DNA based marker assisted selection (MAS) efficiently confirmed the interspecific recombinants. The results provided evidence that MAS can enhance the authenticity of selection in mungbean improvement program.
Atronomical CCD observations of the main Saturn's satellites at Pulkovo Observatory in 2004-2007
NASA Astrophysics Data System (ADS)
Khrutskaya, E. V.; Kiseleva, T. P.; Izmailov, I. S.; Khovrichev, M. Yu.; Berezhnoy, A. A.
2009-08-01
The results of astrometric observations of Saturn’s satellites (S1-S8) obtained using a 26-inch refractor and a normal astrograph at Pulkovo Observatory in 2004-2007 are given. High-accuracy equatorial coordinates of Saturn’s satellites in the system of the UCAC2 reference catalog and the relative “satellite-satellite” positions suitable for specifying their motion theories are obtained. The observations are compared with the DE405 + TASS1.7 and INPOP06 + TASS1.7 theories of motion. The root-mean-square errors of the obtained satellite positions lie within the range of 10-50 mas, as far as the intrinsic convergence is concerned, and 20-70 mas, as far as the extrinsic one is concerned. The observation results are included into the astrometrical database of the Pulkovo Observatory (
Atypical Signaling and Functional Desensitization Response of MAS Receptor to Peptide Ligands
Tirupula, Kalyan C.; Desnoyer, Russell; Speth, Robert C.; Karnik, Sadashiva S.
2014-01-01
MAS is a G protein-coupled receptor (GPCR) implicated in multiple physiological processes. Several physiological peptide ligands such as angiotensin-(1–7), angiotensin fragments and neuropeptide FF (NPFF) are reported to act on MAS. Studies of conventional G protein signaling and receptor desensitization upon stimulation of MAS with the peptide ligands are limited so far. Therefore, we systematically analyzed G protein signals activated by the peptide ligands. MAS-selective non-peptide ligands that were previously shown to activate G proteins were used as controls for comparison on a common cell based assay platform. Activation of MAS by the non-peptide agonist (1) increased intracellular calcium and D-myo-inositol-1-phosphate (IP1) levels which are indicative of the activation of classical Gαq-phospholipase C signaling pathways, (2) decreased Gαi mediated cAMP levels and (3) stimulated Gα12-dependent expression of luciferase reporter. In all these assays, MAS exhibited strong constitutive activity that was inhibited by the non-peptide inverse agonist. Further, in the calcium response assay, MAS was resistant to stimulation by a second dose of the non-peptide agonist after the first activation has waned suggesting functional desensitization. In contrast, activation of MAS by the peptide ligand NPFF initiated a rapid rise in intracellular calcium with very weak IP1 accumulation which is unlike classical Gαq-phospholipase C signaling pathway. NPFF only weakly stimulated MAS-mediated activation of Gα12 and Gαi signaling pathways. Furthermore, unlike non-peptide agonist-activated MAS, NPFF-activated MAS could be readily re-stimulated the second time by the agonists. Functional assays with key ligand binding MAS mutants suggest that NPFF and non-peptide ligands bind to overlapping regions. Angiotensin-(1–7) and other angiotensin fragments weakly potentiated an NPFF-like calcium response at non-physiological concentrations (≥100 µM). Overall, our data suggest that peptide ligands induce atypical signaling and functional desensitization of MAS. PMID:25068582
Reeves, Sarah L; Brown, Devin L; Baek, Jonggyu; Wing, Jeffrey J; Morgenstern, Lewis B; Lisabeth, Lynda D
2015-10-01
Mexican Americans (MAs) have an increased risk of stroke and experience worse poststroke disability than non-Hispanic whites, which may translate into worse poststroke quality of life (QOL). We assessed ethnic differences in poststroke QOL, as well as potential modification of associations by age, sex, and initial stroke severity. Ischemic stroke survivors were identified through the biethnic, population-based Brain Attack Surveillance in Corpus Christi (BASIC) Project. Data were collected from medical records, baseline interviews, and 90-day poststroke interviews. Poststroke QOL was measured at ≈90 days by the validated short-form stroke-specific QOL in 3 domains: overall, physical, and psychosocial (range, 0-5; higher scores represent better QOL). Tobit regression was used to model associations between ethnicity and poststroke QOL scores, adjusted for demographics, clinical characteristics, and prestroke cognition and function. Among 290 eligible stroke survivors (66% MA, 34% non-Hispanic whites, median age=69 years), median scores for overall, physical, and psychosocial poststroke QOL were 3.3, 3.8, and 2.7, respectively. Poststroke QOL was lower for MAs than non-Hispanic whites both overall (mean difference, -0.30; 95% confidence interval, -0.59, -0.01) and in the physical domain (mean difference, -0.47; 95% confidence interval, -0.81, -0.14) after multivariable adjustment. No ethnic difference was found in the psychosocial domain. Age modified the associations between ethnicity and poststroke QOL such that differences were present in older but not in younger ages. Disparities exist in poststroke QOL for MAs and seem to be driven by differences in older stroke patients. Targeted interventions to improve outcomes among MA stroke survivors are urgently needed. © 2015 American Heart Association, Inc.
Reeves, Sarah L; Brown, Devin L; Baek, Jonggyu; Wing, Jeffrey J; Morgenstern, Lewis B; Lisabeth, Lynda D
2015-01-01
Background and Purpose Mexican Americans (MAs) have an increased risk of stroke and experience worse post-stroke disability than non-Hispanic whites (NHWs), which may translate into worse post-stroke quality of life (QOL). We assessed ethnic differences in post-stroke QOL, as well as potential modification of associations by age, sex, and initial stroke severity. Methods Ischemic stroke survivors were identified through the biethnic, population-based Brain Attack Surveillance in Corpus Christi (BASIC) Project. Data were collected from medical records, baseline interviews, and 90-day post-stroke interviews. Post-stroke QOL was measured at approximately 90 days by the validated short-form stroke-specific QOL in 3 domains: overall, physical, and psychosocial (range 0–5; higher scores represent better QOL). Tobit regression was used to model associations between ethnicity and post-stroke QOL scores, adjusted for demographics, clinical characteristics, and pre-stroke cognition and function. Results Among 290 eligible stroke survivors (66% MA, 34% NHW, median age=69 years), median scores for overall, physical, and psychosocial post-stroke QOL were 3.3, 3.8 and 2.7, respectively. Overall post-stroke QOL was lower for MAs than NHWs (mean difference = −0.30, 95%CI:−0.59,−0.01) and in the physical domain (mean difference = −0.47, 95%CI:−0.81,−0.14) after multivariable adjustment. No ethnic difference was found in the psychosocial domain. Age modified the associations between ethnicity and post-stroke QOL such that differences were present in older but not younger ages. Conclusions Disparities exist in post-stroke QOL for MAs and appear to be driven by differences in older stroke patients. Targeted interventions to improve outcomes among MA stroke survivors are urgently needed. PMID:26286542
1981-03-27
a(ireument that differences in recorded data for this size- was . .;mall amongj the various users. An Anthropometry Task group and a Mas...meeting, Dr. K. W. Kennedy of the Anthropometry Tauk group provided a status report on the Air Force proqram to develop appropriate anthropometric and...seating considerations and requirements for the handicapped and elderly . Included in this reference are dimensions for link systems and simple drafting
Retinal Microaneurysms Detection Using Gradient Vector Analysis and Class Imbalance Classification.
Dai, Baisheng; Wu, Xiangqian; Bu, Wei
2016-01-01
Retinal microaneurysms (MAs) are the earliest clinically observable lesions of diabetic retinopathy. Reliable automated MAs detection is thus critical for early diagnosis of diabetic retinopathy. This paper proposes a novel method for the automated MAs detection in color fundus images based on gradient vector analysis and class imbalance classification, which is composed of two stages, i.e. candidate MAs extraction and classification. In the first stage, a candidate MAs extraction algorithm is devised by analyzing the gradient field of the image, in which a multi-scale log condition number map is computed based on the gradient vectors for vessel removal, and then the candidate MAs are localized according to the second order directional derivatives computed in different directions. Due to the complexity of fundus image, besides a small number of true MAs, there are also a large amount of non-MAs in the extracted candidates. Classifying the true MAs and the non-MAs is an extremely class imbalanced classification problem. Therefore, in the second stage, several types of features including geometry, contrast, intensity, edge, texture, region descriptors and other features are extracted from the candidate MAs and a class imbalance classifier, i.e., RUSBoost, is trained for the MAs classification. With the Retinopathy Online Challenge (ROC) criterion, the proposed method achieves an average sensitivity of 0.433 at 1/8, 1/4, 1/2, 1, 2, 4 and 8 false positives per image on the ROC database, which is comparable with the state-of-the-art approaches, and 0.321 on the DiaRetDB1 V2.1 database, which outperforms the state-of-the-art approaches.
NASA Astrophysics Data System (ADS)
Mohammad Alipour, Shirin Hajeb; Rabbani, Hossein
2013-09-01
Diabetic retinopathy (DR) is one of the major complications of diabetes that changes the blood vessels of the retina and distorts patient vision that finally in high stages can lead to blindness. Micro-aneurysms (MAs) are one of the first pathologies associated with DR. The number and the location of MAs are very important in grading of DR. Early diagnosis of micro-aneurysms (MAs) can reduce the incidence of blindness. As MAs are tiny area of blood protruding from vessels in the retina and their size is about 25 to 100 microns, automatic detection of these tiny lesions is still challenging. MAs occurring in the macula can lead to visual loss. Also the position of a lesion such as MAs relative to the macula is a useful feature for analysis and classification of different stages of DR. Because MAs are more distinguishable in fundus fluorescin angiography (FFA) compared to color fundus images, we introduce a new method based on curvelet transform and morphological operations for MAs detection in FFA images. As vessels and MAs are the bright parts of FFA image, firstly extracted vessels by curvelet transform are removed from image. Then morphological operations are applied on resulted image for detecting MAs.
Depressed perivascular sensory innervation of mouse mesenteric arteries with advanced age.
Boerman, Erika M; Segal, Steven S
2016-04-15
The dilatory role for sensory innervation of mesenteric arteries (MAs) is impaired in Old (∼24 months) versus Young (∼4 months) mice. We investigated the nature of this impairment in isolated pressurized MAs. With perivascular sensory nerve stimulation, dilatation and inhibition of sympathetic vasoconstriction observed in Young MAs were lost in Old MAs along with impaired dilatation to calcitonin gene-related peptide (CGRP). Inhibiting NO and prostaglandin synthesis increased CGRP EC50 in Young and Old MAs. Endothelial denudation attenuated dilatation to CGRP in Old MAs yet enhanced dilatation to CGRP in Young MAs while abolishing all dilatations to ACh. In Old MAs, sensory nerve density was reduced and RAMP1 (CGRP receptor component) associated with nuclear regions of endothelial cells in a manner not seen in Young MAs or in smooth muscle cells of either age. With advanced age, loss of dilatory signalling mediated through perivascular sensory nerves may compromise perfusion of visceral organs. Vascular dysfunction and sympathetic nerve activity increase with advancing age. In the gut, blood flow is governed by perivascular sensory and sympathetic nerves but little is known of how their functional role is affected by advanced age. We tested the hypothesis that functional sensory innervation of mesenteric arteries (MAs) is impaired for Old (24 months) versus Young (4 months) C57BL/6 male mice. In cannulated pressurized MAs preconstricted 50% with noradrenaline and treated with guanethidine (to inhibit sympathetic neurotransmission), perivascular nerve stimulation (PNS) evoked dilatation in Young but not Old MAs while dilatations to ACh were not different between age groups. In Young MAs, capsaicin (to inhibit sensory neurotransmission) blocked dilatation and increased constriction during PNS. With no difference in efficacy, the EC50 of CGRP as a vasodilator was ∼6-fold greater in Old versus Young MAs. Inhibiting nitric oxide (l-NAME) and prostaglandin (indomethacin) synthesis increased CGRP EC50 in both age groups. Endothelial denudation reduced the efficacy of dilatation to CGRP by ∼30% in Old MAs yet increased this efficacy ∼15% in Young MAs while all dilatations to ACh were abolished. Immunolabelling revealed reduced density of sensory (CGRP) but not sympathetic (tyrosine hydroxylase) innervation for Old versus Young MAs. Whereas the distribution of CGRP receptor proteins was similar in SMCs, RAMP1 associated with nuclear regions of endothelial cells of Old but not Young MAs. With advanced age, the loss of sensory nerve function and diminished effectiveness of CGRP as a vasodilator is multifaceted and may adversely affect splanchnic perfusion. © 2015 The Authors. The Journal of Physiology © 2015 The Physiological Society.
Grid removal and impact on population dose in full-field digital mammography.
Gennaro, Gisella; Katz, Luc; Souchay, Henri; Klausz, Remy; Alberelli, Claudio; di Maggio, Cosimo
2007-02-01
The study purpose was to determine the impact of anti-scatter grid removal on patient dose, in full field digital mammography. Dose saving, phantom based, was evaluated with the constraint that images acquired with and without grid would provide the same contrast-to-noise ratio (CNR). The digital equipment employed a flat panel detector with cesium iodide for x-ray to light conversion, 100 microm pixel size; the x-ray source was a dual-track tube with selectable filtration. Poly(methyl-emathocrylate) (PMMA) layers in the range 20-70 mm were used to simulate the absorption of different breast thickness, while two Al foils, 0.1 and 0.2 mm thick were used to provide a certain CNR. Images with grid were acquired with the same beam quality as selected in full automatic exposure mode and the mAs levels as close as possible, and the CNR measured for each thickness between 20 and 70 mm. Phantom images without grid were acquired in manual exposure mode, by selecting the same anode/filter combination and kVp as the image with grid at the same thickness, but varying mAs from 10 to 200. For each thickness, an image without aluminum was acquired for each mAs value, in order to obtain a flat image to be used to subtract the scatter nonuniformity from the phantom images. After scatter subtraction, the CNR was measured on images without grid. The mAs value that should be set to acquire a phantom image without grid so that it has the same CNR as the corresponding grid image was calculated. Therefore, mAs reduction percentage was determined versus phantom thickness. Results showed that dose saving was lower than 30% for PMMA equivalent breast thinner than 40 mm, decreased below 10% for intermediate thickness (45-50 mm), but there was no dose gain for thickness beyond 60 mm. By applying the mAs reduction factors to a clinical population derived from a data base of 4622 breasts, dose benefit was quantified in terms of population dose. On the average, the overall dose reduction was about 8%. It was considered small, not sufficient to justify a clinical implementation, and the anti-scatter grid was maintained.
Land Surface Temperature Measurements from EOD MODIS Data
NASA Technical Reports Server (NTRS)
Wan, Zheng-Ming
1998-01-01
We made more tests of the version 2.0 daily Level 2 and Level 3 Land-Surface Temperature (LST) code (PGE 16) jointly with the MODIS Science Data Support Team (SDST). After making minor changes a few times, the PGE16 code has been successfully integrated and tested by MODIS SDST, and recently has passed the inspection at the Goddard Distributed Active Archive Center (DAAC). We conducted a field campaign in the area of Mono Lake, California on March 10, 1998, in order to validate the MODIS LST algorithm in cold and dry conditions. Two MODIS Airborne Simulator (MAS) flights were completed during the field campaign, one before noon, and another around 10 pm PST. The weather condition for the daytime flight was perfect: clear sky, the column water vapor measured by radiosonde around 0.3 cm, and wind speed less than a half meter per second. The quality of MAS data is good for both day and night flights. We analyzed the noise equivalent temperature difference (NE(delta)T) and the calibration accuracy of the seven MAS thermal infrared (TIR) bands, that are used in the MODIS day/night LST algorithm, with daytime MAS data over four flat homogeneous study areas: two on Grant Lake (covered with ice and snow, respectively), one on Mono Lake, and another on the snow field site where we made field measurements. NE(delta)T ranges from 0.2 to 0.6 k for bands 42, 45, 46, and 48. It ranges from 0.8 to 1.1 K for bands 30-32. The day and night MAS data have been used to retrieve surface temperature and emissivities in these bands. A simple method to correct the effect of night thin cirrus has been incorporated into the day/night LST algorithm in dry atmospheric conditions. We compared the retrieved surface temperatures with those measured with TIR spectrometer, radiometers and thermistors in the snow test site, and the retrieved emissivity images with topographic map. The daytime LST values match well within 1 K. The night LST retrieved from MAS data is 3.3 K colder than those from field measurements most likely because of the effect of haze at night. The good agreement among the regional averaged surface temperatures obtained from LST values retrieved at different resolutions increased our confidence in the MODIS day/night LST algorithm.
Zarei, Leila; Sadrkhanlou, Rajabali; Shahrooz, Rasoul; Malekinejad, Hassan; Eilkhanizadeh, Behroz; Ahmadi, Abbas
2014-01-01
This study was aimed to assess the protective effects of Cornus mas fruit extract (CMFE) and vitamin E (Vit E) on sperm quality parameters in the methotrexate (MTX)-treated mice. Forty-eight young adult male mice (8-12 weeks) were randomly divided into six groups including control and test groups. The control group received normal saline orally , and the test groups were treated MTX (20 mg kg(-1), ip, once weekly), MTX + CMFE (250 mg kg(-1)), MTX + CMFE (500 mg kg(-1)), MTX + CMFE (1000 mg kg(-1)), and MTX + Vit E (100 IU kg(-1), po) for 35 consecutive days. On day 35, after euthanasia the epididymal sperms were isolated. Then the total mean sperm count, sperm viability and motility were determined. The total antioxidant capacity (TAOC) of all experimental groups were also evaluated. The MTX-treated animals showed a significant changes in all parameters of sperm quality assessment compared to the control group. Both Vit E and CMFE were able to protect from MTX-induced effects on sperm maturity and DNA damage. Co-administration of MTX and CMFE and/or Vit E resulted in protection from MTX-reduced TAOC. In conclusion, these data suggested that MTX administration could adversely affect the sperm quality. Moreover, the protective effect of Vit E and CMFE on MTX-induced sperm toxicity was also documented.
Ahmad, J I; Mishra, R K
2015-01-01
The establishment of minimal access surgery (MAS) in the last three decades brought new dimensions to surgical training. The sole role of traditional apprenticeship training model was challenged and adjunctive surgical simulation models were introduced. Knowledge of the trainees' educational needs is important in designing MAS training curriculum. To study the MAS educational needs of trainees from Africa, review MAS training models and offer recommendations for MAS training. Data was obtained from questionnaires filled by trainees from Africa who attended the monthly MAS training at the World Laparoscopy Hospital, India from October 2013 to May 2014 about their MAS educational needs. There were 38 trainees from different parts of Africa (Central, East, North, South and West Africa) with average age of 41.92 ± 8.67 years (minimum-28 years and maximum 63 years) and majority were males (92%). General surgeons constituted 57% while Gynaecologists were 41%. Only a quarter have MAS training integrated in their training curriculum. Box trainers, Animal models, live human surgeries and virtual reality simulation were the commonest models used in previous trainings and favoured in the educational needs for MAS training. Using cadaveric models and self sponsorship were deemphasised. Widespread application of MAS, globalisation and trainees educational needs call for establishing training programmes. Box trainers, animal models, live human surgeries and virtual reality simulators should be adopted and a synergy between Postgraduate surgical programmes, biomedical industry, universities and trainees will facilitate the setting of MAS skills laboratories and programmes.
Angiotensin-(1-7)/Mas axis modulates fear memory and extinction in mice.
Lazaroni, Thiago Luiz do Nascimento; Bastos, Cristiane Perácio; Moraes, Márcio Flávio Dutra; Santos, Robson Souza; Pereira, Grace Schenatto
2016-01-01
Inappropriate defense-alerting reaction to fear is a common feature of neuropsychiatric diseases. Therefore, impairments in brain circuits, as well as in molecular pathways underlying the neurovegetative adjustments to fear may play an essential role on developing neuropsychiatric disorders. Here we tested the hypothesis that interfering with angiotensin-(1-7) [Ang-(1-7)]/Mas receptor axis homeostasis, which appears to be essential to arterial pressure control, would affect fear memory and extinction. Mas knockout (MasKO) mice, in FVB/N background, showed normal cued fear memory and extinction, but increased freezing in response to context. Next, as FVB/N has poor performance in contextual fear memory, we tested MasKO in mixed 129xC57BL/6 background. MasKO mice behaved similarly to wild-type (WT), but memory extinction was slower in contextual fear conditioning to a weak protocol (1CS/US). In addition, delayed extinction in MasKO mice was even more pronounced after a stronger protocol (3CS/US). We showed previously that Angiotensin II receptor AT1 antagonist, losantan, rescued object recognition memory deficit in MasKO mice. Here, losartan was also effective. Memory extinction was accelerated in MasKO mice after treatment with losartan. In conclusion, we showed for the first time that Ang-(1-7)/Mas axis may modulate fear memory extinction. Furthermore, we suggest MasKO mice as an animal model to study post-traumatic stress disorder (PTSD). Copyright © 2015 Elsevier Inc. All rights reserved.
Atmospheric Science Data Center
2015-11-24
... Transition Experiment (ASTEX) ER-2 MODIS Airborne Simulator (MAS) Data Project Title: MAS ... Temporal Resolution: Each granule contains one flight track File Format: HDF Tools: ... Additional Info: NASA ER-2 MODIS Airborne Simulator (MAS) SCAR-B Block: SCAR-B ...
Dubow, Michael; Pinhas, Alexander; Shah, Nishit; Cooper, Robert F.; Gan, Alexander; Gentile, Ronald C.; Hendrix, Vernon; Sulai, Yusufu N.; Carroll, Joseph; Chui, Toco Y. P.; Walsh, Joseph B.; Weitz, Rishard; Dubra, Alfredo; Rosen, Richard B.
2014-01-01
Purpose. Microaneurysms (MAs) are considered a hallmark of retinal vascular disease, yet what little is known about them is mostly based upon histology, not clinical observation. Here, we use the recently developed adaptive optics scanning light ophthalmoscope (AOSLO) fluorescein angiography (FA) to image human MAs in vivo and to expand on previously described MA morphologic classification schemes. Methods. Patients with vascular retinopathies (diabetic, hypertensive, and branch and central retinal vein occlusion) were imaged with reflectance AOSLO and AOSLO FA. Ninety-three MAs, from 14 eyes, were imaged and classified according to appearance into six morphologic groups: focal bulge, saccular, fusiform, mixed, pedunculated, and irregular. The MA perimeter, area, and feret maximum and minimum were correlated to morphology and retinal pathology. Select MAs were imaged longitudinally in two eyes. Results. Adaptive optics scanning light ophthalmoscope fluorescein angiography imaging revealed microscopic features of MAs not appreciated on conventional images. Saccular MAs were most prevalent (47%). No association was found between the type of retinal pathology and MA morphology (P = 0.44). Pedunculated and irregular MAs were among the largest MAs with average areas of 4188 and 4116 μm2, respectively. Focal hypofluorescent regions were noted in 30% of MAs and were more likely to be associated with larger MAs (3086 vs. 1448 μm2, P = 0.0001). Conclusions. Retinal MAs can be classified in vivo into six different morphologic types, according to the geometry of their two-dimensional (2D) en face view. Adaptive optics scanning light ophthalmoscope fluorescein angiography imaging of MAs offers the possibility of studying microvascular change on a histologic scale, which may help our understanding of disease progression and treatment response. PMID:24425852
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suiter, Christopher L.; Paramasivam, Sivakumar; Hou, Guangjin
Recently, we have demonstrated that considerable inherent sensitivity gains are attained in MAS NMR spectra acquired by nonuniform sampling (NUS) and introduced maximum entropy interpolation (MINT) processing that assures the linearity of transformation between the time and frequency domains. In this report, we examine the utility of the NUS/MINT approach in multidimensional datasets possessing high dynamic range, such as homonuclear 13C–13C correlation spectra. We demonstrate on model compounds and on 1–73-(U-13C,15N)/74–108-(U-15N) E. coli thioredoxin reassembly, that with appropriately constructed 50 % NUS schedules inherent sensitivity gains of 1.7–2.1-fold are readily reached in such datasets. We show that both linearity andmore » line width are retained under these experimental conditions throughout the entire dynamic range of the signals. Furthermore, we demonstrate that the reproducibility of the peak intensities is excellent in the NUS/MINT approach when experiments are repeated multiple times and identical experimental and processing conditions are employed. Finally, we discuss the principles for design and implementation of random exponentially biased NUS sampling schedules for homonuclear 13C–13C MAS correlation experiments that yield high quality artifact-free datasets.« less
Suiter, Christopher L.; Paramasivam, Sivakumar; Hou, Guangjin; Sun, Shangjin; Rice, David; Hoch, Jeffrey C.; Rovnyak, David
2014-01-01
Recently, we have demonstrated that considerable inherent sensitivity gains are attained in MAS NMR spectra acquired by nonuniform sampling (NUS) and introduced maximum entropy interpolation (MINT) processing that assures the linearity of transformation between the time and frequency domains. In this report, we examine the utility of the NUS/MINT approach in multidimensional datasets possessing high dynamic range, such as homonuclear 13C–13C correlation spectra. We demonstrate on model compounds and on 1–73-(U-13C, 15N)/74–108-(U-15N) E. coli thioredoxin reassembly, that with appropriately constructed 50 % NUS schedules inherent sensitivity gains of 1.7–2.1-fold are readily reached in such datasets. We show that both linearity and line width are retained under these experimental conditions throughout the entire dynamic range of the signals. Furthermore, we demonstrate that the reproducibility of the peak intensities is excellent in the NUS/MINT approach when experiments are repeated multiple times and identical experimental and processing conditions are employed. Finally, we discuss the principles for design and implementation of random exponentially biased NUS sampling schedules for homonuclear 13C–13C MAS correlation experiments that yield high-quality artifact-free datasets. PMID:24752819
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schafer, S.; Nithiananthan, S.; Mirota, D. J.
Purpose: A flat-panel detector based mobile isocentric C-arm for cone-beam CT (CBCT) has been developed to allow intraoperative 3D imaging with sub-millimeter spatial resolution and soft-tissue visibility. Image quality and radiation dose were evaluated in spinal surgery, commonly relying on lower-performance image intensifier based mobile C-arms. Scan protocols were developed for task-specific imaging at minimum dose, in-room exposure was evaluated, and integration of the imaging system with a surgical guidance system was demonstrated in preclinical studies of minimally invasive spine surgery. Methods: Radiation dose was assessed as a function of kilovolt (peak) (80-120 kVp) and milliampere second using thoracic andmore » lumbar spine dosimetry phantoms. In-room radiation exposure was measured throughout the operating room for various CBCT scan protocols. Image quality was assessed using tissue-equivalent inserts in chest and abdomen phantoms to evaluate bone and soft-tissue contrast-to-noise ratio as a function of dose, and task-specific protocols (i.e., visualization of bone or soft-tissues) were defined. Results were applied in preclinical studies using a cadaveric torso simulating minimally invasive, transpedicular surgery. Results: Task-specific CBCT protocols identified include: thoracic bone visualization (100 kVp; 60 mAs; 1.8 mGy); lumbar bone visualization (100 kVp; 130 mAs; 3.2 mGy); thoracic soft-tissue visualization (100 kVp; 230 mAs; 4.3 mGy); and lumbar soft-tissue visualization (120 kVp; 460 mAs; 10.6 mGy) - each at (0.3 x 0.3 x 0.9 mm{sup 3}) voxel size. Alternative lower-dose, lower-resolution soft-tissue visualization protocols were identified (100 kVp; 230 mAs; 5.1 mGy) for the lumbar region at (0.3 x 0.3 x 1.5 mm{sup 3}) voxel size. Half-scan orbit of the C-arm (x-ray tube traversing under the table) was dosimetrically advantageous (prepatient attenuation) with a nonuniform dose distribution ({approx}2 x higher at the entrance side than at isocenter, and {approx}3-4 lower at the exit side). The in-room dose (microsievert) per unit scan dose (milligray) ranged from {approx}21 {mu}Sv/mGy on average at tableside to {approx}0.1 {mu}Sv/mGy at 2.0 m distance to isocenter. All protocols involve surgical staff stepping behind a shield wall for each CBCT scan, therefore imparting {approx}zero dose to staff. Protocol implementation in preclinical cadaveric studies demonstrate integration of the C-arm with a navigation system for spine surgery guidance-specifically, minimally invasive vertebroplasty in which the system provided accurate guidance and visualization of needle placement and bone cement distribution. Cumulative dose including multiple intraoperative scans was {approx}11.5 mGy for CBCT-guided thoracic vertebroplasty and {approx}23.2 mGy for lumbar vertebroplasty, with dose to staff at tableside reduced to {approx}1 min of fluoroscopy time ({approx}40-60 {mu}Sv), compared to 5-11 min for the conventional approach. Conclusions: Intraoperative CBCT using a high-performance mobile C-arm prototype demonstrates image quality suitable to guidance of spine surgery, with task-specific protocols providing an important basis for minimizing radiation dose, while maintaining image quality sufficient for surgical guidance. Images demonstrate a significant advance in spatial resolution and soft-tissue visibility, and CBCT guidance offers the potential to reduce fluoroscopy reliance, reducing cumulative dose to patient and staff. Integration with a surgical guidance system demonstrates precise tracking and visualization in up-to-date images (alleviating reliance on preoperative images only), including detection of errors or suboptimal surgical outcomes in the operating room.« less
Update on VLBA Astrometry of Cassini
NASA Astrophysics Data System (ADS)
Jones, Dayton L.; Folkner, William M.; Jacobson, Robert A.; Jacobs, Christopher S.; Romney, Jon; Dhawan, Vivek; Fomalont, Edward B.
2015-01-01
The NRAO Very Long Baseline Array (VLBA) has been used to measure positions of the Cassini spacecraft 2-3 times per year during the decade since it arrived at Saturn. Combining these measurements with fits for Cassini's orbit about Saturn from Doppler tracking by the NASA Deep Space Network provides accurate positions for the Saturn system barycenter in the inertial International Celestial Reference Frame (ICRF) at each observing epoch. These positions in turn help to improve our knowledge of Saturn's orbit and thus the planetary ephemeris on which future interplanetary spacecraft navigation, pulsar timing, and studies of solar system dynamics depend. This observational program will continue to the end of Cassini's mission in 2017, thereby covering as large a fraction of Saturn's orbital period as possible. A multi-year period of accurate astrometry also increases the range of times over which ephemeris improvements can be extrapolated. Our current residuals with respect to JPL's DE430 ephemeris are approximately 0.2 mas in right ascension and 0.3 mas in declination. The primary error sources are residual troposphere delay calibration errors and uncertainties in the ICRF positions of some of our phase reference sources. The reference source position uncertainties are being reduced by continuing VLBI observations. Similar VLBI techniques will be applied to the Juno spacecraft when it begins orbiting Jupiter in 2016, thereby improving the orbit for this planet as well. This work has been carried out at the Jet Propulsion Laboratory, California Institute of Technology, under contract with the National Aeronautics and Space Administration. Support from the NASA Planetary Astronomy Program is gratefully acknowledged. The VLBA is a facility of the National Radio Astronomy Observatory, which is operated by Associated Universities, Inc, under a cooperative agreement with the National Science Foundation.
Radiation dose reduction in medical x-ray CT via Fourier-based iterative reconstruction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fahimian, Benjamin P.; Zhao Yunzhe; Huang Zhifeng
Purpose: A Fourier-based iterative reconstruction technique, termed Equally Sloped Tomography (EST), is developed in conjunction with advanced mathematical regularization to investigate radiation dose reduction in x-ray CT. The method is experimentally implemented on fan-beam CT and evaluated as a function of imaging dose on a series of image quality phantoms and anonymous pediatric patient data sets. Numerical simulation experiments are also performed to explore the extension of EST to helical cone-beam geometry. Methods: EST is a Fourier based iterative algorithm, which iterates back and forth between real and Fourier space utilizing the algebraically exact pseudopolar fast Fourier transform (PPFFT). Inmore » each iteration, physical constraints and mathematical regularization are applied in real space, while the measured data are enforced in Fourier space. The algorithm is automatically terminated when a proposed termination criterion is met. Experimentally, fan-beam projections were acquired by the Siemens z-flying focal spot technology, and subsequently interleaved and rebinned to a pseudopolar grid. Image quality phantoms were scanned at systematically varied mAs settings, reconstructed by EST and conventional reconstruction methods such as filtered back projection (FBP), and quantified using metrics including resolution, signal-to-noise ratios (SNRs), and contrast-to-noise ratios (CNRs). Pediatric data sets were reconstructed at their original acquisition settings and additionally simulated to lower dose settings for comparison and evaluation of the potential for radiation dose reduction. Numerical experiments were conducted to quantify EST and other iterative methods in terms of image quality and computation time. The extension of EST to helical cone-beam CT was implemented by using the advanced single-slice rebinning (ASSR) method. Results: Based on the phantom and pediatric patient fan-beam CT data, it is demonstrated that EST reconstructions with the lowest scanner flux setting of 39 mAs produce comparable image quality, resolution, and contrast relative to FBP with the 140 mAs flux setting. Compared to the algebraic reconstruction technique and the expectation maximization statistical reconstruction algorithm, a significant reduction in computation time is achieved with EST. Finally, numerical experiments on helical cone-beam CT data suggest that the combination of EST and ASSR produces reconstructions with higher image quality and lower noise than the Feldkamp Davis and Kress (FDK) method and the conventional ASSR approach. Conclusions: A Fourier-based iterative method has been applied to the reconstruction of fan-bean CT data with reduced x-ray fluence. This method incorporates advantageous features in both real and Fourier space iterative schemes: using a fast and algebraically exact method to calculate forward projection, enforcing the measured data in Fourier space, and applying physical constraints and flexible regularization in real space. Our results suggest that EST can be utilized for radiation dose reduction in x-ray CT via the readily implementable technique of lowering mAs settings. Numerical experiments further indicate that EST requires less computation time than several other iterative algorithms and can, in principle, be extended to helical cone-beam geometry in combination with the ASSR method.« less
Radiation dose reduction in medical x-ray CT via Fourier-based iterative reconstruction.
Fahimian, Benjamin P; Zhao, Yunzhe; Huang, Zhifeng; Fung, Russell; Mao, Yu; Zhu, Chun; Khatonabadi, Maryam; DeMarco, John J; Osher, Stanley J; McNitt-Gray, Michael F; Miao, Jianwei
2013-03-01
A Fourier-based iterative reconstruction technique, termed Equally Sloped Tomography (EST), is developed in conjunction with advanced mathematical regularization to investigate radiation dose reduction in x-ray CT. The method is experimentally implemented on fan-beam CT and evaluated as a function of imaging dose on a series of image quality phantoms and anonymous pediatric patient data sets. Numerical simulation experiments are also performed to explore the extension of EST to helical cone-beam geometry. EST is a Fourier based iterative algorithm, which iterates back and forth between real and Fourier space utilizing the algebraically exact pseudopolar fast Fourier transform (PPFFT). In each iteration, physical constraints and mathematical regularization are applied in real space, while the measured data are enforced in Fourier space. The algorithm is automatically terminated when a proposed termination criterion is met. Experimentally, fan-beam projections were acquired by the Siemens z-flying focal spot technology, and subsequently interleaved and rebinned to a pseudopolar grid. Image quality phantoms were scanned at systematically varied mAs settings, reconstructed by EST and conventional reconstruction methods such as filtered back projection (FBP), and quantified using metrics including resolution, signal-to-noise ratios (SNRs), and contrast-to-noise ratios (CNRs). Pediatric data sets were reconstructed at their original acquisition settings and additionally simulated to lower dose settings for comparison and evaluation of the potential for radiation dose reduction. Numerical experiments were conducted to quantify EST and other iterative methods in terms of image quality and computation time. The extension of EST to helical cone-beam CT was implemented by using the advanced single-slice rebinning (ASSR) method. Based on the phantom and pediatric patient fan-beam CT data, it is demonstrated that EST reconstructions with the lowest scanner flux setting of 39 mAs produce comparable image quality, resolution, and contrast relative to FBP with the 140 mAs flux setting. Compared to the algebraic reconstruction technique and the expectation maximization statistical reconstruction algorithm, a significant reduction in computation time is achieved with EST. Finally, numerical experiments on helical cone-beam CT data suggest that the combination of EST and ASSR produces reconstructions with higher image quality and lower noise than the Feldkamp Davis and Kress (FDK) method and the conventional ASSR approach. A Fourier-based iterative method has been applied to the reconstruction of fan-bean CT data with reduced x-ray fluence. This method incorporates advantageous features in both real and Fourier space iterative schemes: using a fast and algebraically exact method to calculate forward projection, enforcing the measured data in Fourier space, and applying physical constraints and flexible regularization in real space. Our results suggest that EST can be utilized for radiation dose reduction in x-ray CT via the readily implementable technique of lowering mAs settings. Numerical experiments further indicate that EST requires less computation time than several other iterative algorithms and can, in principle, be extended to helical cone-beam geometry in combination with the ASSR method.
Radiation dose reduction in medical x-ray CT via Fourier-based iterative reconstruction
Fahimian, Benjamin P.; Zhao, Yunzhe; Huang, Zhifeng; Fung, Russell; Mao, Yu; Zhu, Chun; Khatonabadi, Maryam; DeMarco, John J.; Osher, Stanley J.; McNitt-Gray, Michael F.; Miao, Jianwei
2013-01-01
Purpose: A Fourier-based iterative reconstruction technique, termed Equally Sloped Tomography (EST), is developed in conjunction with advanced mathematical regularization to investigate radiation dose reduction in x-ray CT. The method is experimentally implemented on fan-beam CT and evaluated as a function of imaging dose on a series of image quality phantoms and anonymous pediatric patient data sets. Numerical simulation experiments are also performed to explore the extension of EST to helical cone-beam geometry. Methods: EST is a Fourier based iterative algorithm, which iterates back and forth between real and Fourier space utilizing the algebraically exact pseudopolar fast Fourier transform (PPFFT). In each iteration, physical constraints and mathematical regularization are applied in real space, while the measured data are enforced in Fourier space. The algorithm is automatically terminated when a proposed termination criterion is met. Experimentally, fan-beam projections were acquired by the Siemens z-flying focal spot technology, and subsequently interleaved and rebinned to a pseudopolar grid. Image quality phantoms were scanned at systematically varied mAs settings, reconstructed by EST and conventional reconstruction methods such as filtered back projection (FBP), and quantified using metrics including resolution, signal-to-noise ratios (SNRs), and contrast-to-noise ratios (CNRs). Pediatric data sets were reconstructed at their original acquisition settings and additionally simulated to lower dose settings for comparison and evaluation of the potential for radiation dose reduction. Numerical experiments were conducted to quantify EST and other iterative methods in terms of image quality and computation time. The extension of EST to helical cone-beam CT was implemented by using the advanced single-slice rebinning (ASSR) method. Results: Based on the phantom and pediatric patient fan-beam CT data, it is demonstrated that EST reconstructions with the lowest scanner flux setting of 39 mAs produce comparable image quality, resolution, and contrast relative to FBP with the 140 mAs flux setting. Compared to the algebraic reconstruction technique and the expectation maximization statistical reconstruction algorithm, a significant reduction in computation time is achieved with EST. Finally, numerical experiments on helical cone-beam CT data suggest that the combination of EST and ASSR produces reconstructions with higher image quality and lower noise than the Feldkamp Davis and Kress (FDK) method and the conventional ASSR approach. Conclusions: A Fourier-based iterative method has been applied to the reconstruction of fan-bean CT data with reduced x-ray fluence. This method incorporates advantageous features in both real and Fourier space iterative schemes: using a fast and algebraically exact method to calculate forward projection, enforcing the measured data in Fourier space, and applying physical constraints and flexible regularization in real space. Our results suggest that EST can be utilized for radiation dose reduction in x-ray CT via the readily implementable technique of lowering mAs settings. Numerical experiments further indicate that EST requires less computation time than several other iterative algorithms and can, in principle, be extended to helical cone-beam geometry in combination with the ASSR method. PMID:23464329
Wigal, Timothy; Brams, Matthew; Frick, Glen; Yan, Brian; Madhoo, Manisha
2018-06-18
The objective of this paper was to evaluate the efficacy, duration of effect, and tolerability of SHP465 mixed amphetamine salts (MAS) extended-release versus placebo and immediate-release MAS (MAS IR) in adults with attention-deficit/hyperactivity disorder (ADHD). Adults with ADHD Rating Scale, Version IV (ADHD-RS-IV) scores ≥24 were randomized to SHP465 MAS (50 or 75 mg), placebo, or 25 mg MAS IR in a double-blind, three-period, crossover study using a simulated adult workplace environment. On the final day of each 7-day treatment period, efficacy was assessed for 16 h postdose. Primary efficacy analyses for Permanent Product Measure of Performance (PERMP) total score averaged across all postdose assessments and each postdose time point were conducted in the intent-to-treat population using a mixed linear model. Secondary end-points included PERMP problems attempted and answered correctly and ADHD-RS-IV scores based on clinician ratings of counselor observations using the Time Segment Rating System and participant self-report. Tolerability assessments included treatment-emergent adverse events (TEAEs) and vital signs. Least squares mean (95% CI) treatment differences (combined 50/75 mg SHP465 MAS-placebo) significantly favored SHP465 MAS over placebo for PERMP total score averaged across all postdose assessments (18.38 [11.28, 25.47]; P < .0001) and at each postdose assessment (all P < .02). Nominal superiority of MAS IR over placebo for PERMP total score averaged across all postdose assessments was observed (nominal P = .0001); treatment differences between SHP465 MAS and MAS IR were not significant (nominal P = .2443). The two most frequently reported TEAEs associated with SHP465 MAS were insomnia (36.5%) and anorexia (21.2%). Mean increases in pulse and blood pressure with SHP465 MAS exceeded those of placebo. SHP465 MAS (combined 50/75 mg) significantly improved PERMP total score versus placebo, with superiority observed from 2 to 16 h postdose. The tolerability profile of SHP465 MAS was similar to previous reports of SHP465 MAS in adults with ADHD. https://clinicaltrials.gov/ct2/show/NCT00928148 identifier is NCT00928148.
NASA Technical Reports Server (NTRS)
Arnold, G. Thomas; Fitzgerald, Michael; Grant, Patrick S.; King, Michael D.
1994-01-01
Calibration of the visible and near-infrared channels of the MODIS Airborne Simulator (MAS) is derived from observations of a calibrated light source. For the 1991 FIRE-Cirrus field experiment, the calibrated light source was the NASA Goddard 48-inch integrating hemisphere. Laboratory tests during the FIRE Cirrus field experiment were conducted to calibrate the hemisphere and from the hemisphere to the MAS. The purpose of this report is to summarize the FIRE-Cirrus hemisphere calibration, and then describe how the MAS was calibrated from observations of the hemisphere data. All MAS calibration measurements are presented, and determination of the MAS calibration coefficients (raw counts to radiance conversion) is discussed. Thermal sensitivity of the MAS visible and near-infrared calibration is also discussed. Typically, the MAS in-flight is 30 to 60 degrees C colder than the room temperature laboratory calibration. Results from in-flight temperature measurements and tests of the MAS in a cold chamber are given, and from these, equations are derived to adjust the MAS in-flight data to what the value would be at laboratory conditions. For FIRE-Cirrus data, only channels 3 through 6 were found to be temperature sensitive. The final section of this report describes comparisons to an independent MAS (room temperature) calibration by Ames personnel using their 30-inch integrating sphere.
Kyiv UkrVO glass archives: new life
NASA Astrophysics Data System (ADS)
Pakuliak, L.; Golovnya, V.; Andruk, V.; Shatokhina, S.; Yizhakevych, O.; Kazantseva, L.; Lukianchuk, V.
In the framework of UkrVO national project the new methods of plate digital image processing are developed. The photographic material of the UkrVO Joint Digital Archive (JDA) is used for the solution of classic astrometric problem - positional and photometric determinations of objects registered on the plates. The results of tested methods show that the positional rms errors are better than ±150 mas for both coordinates and photometric ones are better than ±0.20m with the Tycho-2 catalogue as reference.
NASA Astrophysics Data System (ADS)
Peng, Yung-Kang; Lui, Cathy N. P.; Chen, Yu-Wei; Chou, Shang-Wei; Chou, Pi-Tai; Yung, Ken K. L.; Edman Tsang, S. C.
2018-01-01
Tagging recognition group(s) on superparamagnetic iron oxide is known to aid localisation (imaging), stimulation and separation of biological entities using magnetic resonance imaging (MRI) and magnetic agitation/separation (MAS) techniques. Despite the wide applicability of iron oxide nanoparticles in T 2-weighted MRI and MAS, the quality of the images and safe manipulation of the exceptionally delicate neural cells in a live brain are currently the key challenges. Here, we demonstrate the engineered manganese oxide clusters-iron oxide core-shell nanoparticle as an MR dual-modal contrast agent for neural stem cells (NSCs) imaging and magnetic manipulation in live rodents. As a result, using this engineered nanoparticle and associated technologies, identification, stimulation and transportation of labelled potentially multipotent NSCs from a specific location of a live brain to another by magnetic means for self-healing therapy can therefore be made possible.
NASA Astrophysics Data System (ADS)
Liu, Junchi; Zarshenas, Amin; Qadir, Ammar; Wei, Zheng; Yang, Limin; Fajardo, Laurie; Suzuki, Kenji
2018-03-01
To reduce cumulative radiation exposure and lifetime risks for radiation-induced cancer from breast cancer screening, we developed a deep-learning-based supervised image-processing technique called neural network convolution (NNC) for radiation dose reduction in DBT. NNC employed patched-based neural network regression in a convolutional manner to convert lower-dose (LD) to higher-dose (HD) tomosynthesis images. We trained our NNC with quarter-dose (25% of the standard dose: 12 mAs at 32 kVp) raw projection images and corresponding "teaching" higher-dose (HD) images (200% of the standard dose: 99 mAs at 32 kVp) of a breast cadaver phantom acquired with a DBT system (Selenia Dimensions, Hologic, CA). Once trained, NNC no longer requires HD images. It converts new LD images to images that look like HD images; thus the term "virtual" HD (VHD) images. We reconstructed tomosynthesis slices on a research DBT system. To determine a dose reduction rate, we acquired 4 studies of another test phantom at 4 different radiation doses (1.35, 2.7, 4.04, and 5.39 mGy entrance dose). Structural SIMilarity (SSIM) index was used to evaluate the image quality. For testing, we collected half-dose (50% of the standard dose: 32+/-14 mAs at 33+/-5 kVp) and full-dose (standard dose: 68+/-23 mAs at 33+/-5 kvp) images of 10 clinical cases with the DBT system at University of Iowa Hospitals and Clinics. NNC converted half-dose DBT images of 10 clinical cases to VHD DBT images that were equivalent to full dose DBT images. Our cadaver phantom experiment demonstrated 79% dose reduction.
35Cl dynamic nuclear polarization solid-state NMR of active pharmaceutical ingredients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hirsh, David A.; Rossini, Aaron J.; Emsley, Lyndon
In this paper, we show how to obtain efficient dynamic nuclear polarization (DNP) enhanced 35Cl solid-state NMR (SSNMR) spectra at 9.4 T and demonstrate how they can be used to characterize the molecular-level structure of hydrochloride salts of active pharmaceutical ingredients (APIs) in both bulk and low wt% API dosage forms. 35Cl SSNMR central-transition powder patterns of chloride ions are typically tens to hundreds of kHz in breadth, and most cannot be excited uniformly with high-power rectangular pulses or acquired under conditions of magic-angle spinning (MAS). Herein, we demonstrate the combination of DNP and 1H– 35Cl broadband adiabatic inversion crossmore » polarization (BRAIN-CP) experiments for the acquisition of high quality wideline spectra of APIs under static sample conditions, and obtain signals up to 50 times greater than in spectra acquired without the use of DNP at 100 K. We report a new protocol, called spinning-on spinning-off (SOSO) acquisition, where MAS is applied during part of the polarization delay to increase the DNP enhancements and then the MAS rotation is stopped so that a wideline 35Cl NMR powder pattern free from the effects of spinning sidebands can be acquired under static conditions. This method provides an additional two-fold signal enhancement compared to DNP-enhanced SSNMR spectra acquired under purely static conditions. DNP-enhanced 35Cl experiments are used to characterize APIs in bulk and dosage forms with Cl contents as low as 0.45 wt%. These results are compared to DNP-enhanced 1H– 13C CP/MAS spectra of APIs in dosage forms, which are often hindered by interfering signals arising from the binders, fillers and other excipient materials.« less
35Cl dynamic nuclear polarization solid-state NMR of active pharmaceutical ingredients
Hirsh, David A.; Rossini, Aaron J.; Emsley, Lyndon; ...
2016-08-24
In this paper, we show how to obtain efficient dynamic nuclear polarization (DNP) enhanced 35Cl solid-state NMR (SSNMR) spectra at 9.4 T and demonstrate how they can be used to characterize the molecular-level structure of hydrochloride salts of active pharmaceutical ingredients (APIs) in both bulk and low wt% API dosage forms. 35Cl SSNMR central-transition powder patterns of chloride ions are typically tens to hundreds of kHz in breadth, and most cannot be excited uniformly with high-power rectangular pulses or acquired under conditions of magic-angle spinning (MAS). Herein, we demonstrate the combination of DNP and 1H– 35Cl broadband adiabatic inversion crossmore » polarization (BRAIN-CP) experiments for the acquisition of high quality wideline spectra of APIs under static sample conditions, and obtain signals up to 50 times greater than in spectra acquired without the use of DNP at 100 K. We report a new protocol, called spinning-on spinning-off (SOSO) acquisition, where MAS is applied during part of the polarization delay to increase the DNP enhancements and then the MAS rotation is stopped so that a wideline 35Cl NMR powder pattern free from the effects of spinning sidebands can be acquired under static conditions. This method provides an additional two-fold signal enhancement compared to DNP-enhanced SSNMR spectra acquired under purely static conditions. DNP-enhanced 35Cl experiments are used to characterize APIs in bulk and dosage forms with Cl contents as low as 0.45 wt%. These results are compared to DNP-enhanced 1H– 13C CP/MAS spectra of APIs in dosage forms, which are often hindered by interfering signals arising from the binders, fillers and other excipient materials.« less
Bhandari, Mohit; Bannuru, Raveendhara R.; Babins, Eric M.; Martel-Pelletier, Johanne; Khan, Moin; Raynauld, Jean-Pierre; Frankovich, Renata; Mcleod, Deanna; Devji, Tahira; Phillips, Mark; Schemitsch, Emil H.; Pelletier, Jean-Pierre
2017-01-01
Osteoarthritis (OA) is a chronic condition characterized by a loss of joint cartilage and is a major cause of disability in Canada, with an estimated CN$195 billion annual cost. Knee OA leads to persistent pain and loss of function, and treatment goals primarily focus on symptom relief and retention of function. Intra-articular hyaluronic acid (IAHA) has therapeutic benefits, and numerous recently published meta-analyses (MAs) and commentaries have highlighted new evidence on the role of IAHA therapy for knee OA. A diverse, multidisciplinary group of specialists met independently in closed sessions to review findings from eight MAs with literature search end dates no earlier than 2012 to address controversies surrounding IAHA therapy for mild-to-moderate knee OA within the Canadian treatment context. Outcomes from a total of eight MAs were reviewed, and consistent and statistically significant improvements in pain, function and stiffness up to 26 weeks were found with IAHA therapy compared with IA placebo or controls, regardless of MA size or trial quality. These findings are in line with those of a Cochrane review, another recent systematic review and patient satisfaction survey. Overall, three MAs reported outcomes based on molecular weight (MW), with the two reporting effect sizes showing significantly improved pain outcomes for higher compared with lower MW HAs. Recent evidence suggests that HA therapy is well tolerated with no increased risk of serious adverse events compared with placebo and the full therapeutic effect of IAHA therapy appears to have considerable clinical importance, consisting of the combined IA placebo and HA therapeutic effects. IAHA therapy is a well-tolerated and effective option for patients with mild-to-moderate knee OA failing first-line pharmacological therapy. PMID:28932293
The First US Naval Observatory CCD Astrograph Catalog
NASA Astrophysics Data System (ADS)
Zacharias, N.; Urban, S. E.; Zacharias, M. I.; Hall, D. M.; Wycoff, G. L.; Rafferty, T. J.; Germain, M. E.; Holdenried, E. R.; Pohlman, J. W.; Gauss, F. S.; Monet, D. G.; Winter, L.
2000-10-01
The USNO CCD Astrograph (UCA) started an astrometric survey in 1998 February at Cerro Tololo, Chile. This first, preliminary catalog (UCAC1) includes data taken up to 1999 November with about 80% of the Southern Hemisphere covered. Observing continues, and full sky coverage is expected by mid-2003 after moving the instrument to a Northern Hemisphere site in early 2001. The survey is performed in a single bandpass (579-642 nm), a twofold overlap pattern of fields, and with a long and a short exposure on each field. Stars in the magnitude range 10-14 have positional precisions of <=20 mas. At the limiting magnitude of R~16 mag, the positional precision is 70 mas. The UCAC aims at a density (stars per square degree) larger than that of the Guide Star Catalog (GSC) with a positional accuracy similar to Tycho. The UCAC program is a major step toward a high-precision densification of the optical reference frame in the post-Hipparcos era, and the first stage, the UCAC1 contains over 27 million stars. Preliminary proper motions are included, which were derived from Tycho-2, Hipparcos, and ground-based transit circle and photographic surveys for the bright stars (V<=12.5 mag) and the USNO A2.0 for the fainter stars. The accuracy of the proper motions varies widely, from 1 to over 15 mas yr-1. The UCAC1 is available on CD-ROM from the US Naval Observatory.
Separated fringe packet observations with the Chara Array. II. ω Andromeda, HD 178911, and ξ Cephei
DOE Office of Scientific and Technical Information (OSTI.GOV)
Farrington, C. D.; Ten Brummelaar, T. A.; Turner, N. H.
When observed with optical long-baseline interferometers, components of a binary star that are sufficiently separated produce their own interferometric fringe packets; these are referred to as separated fringe packet (SFP) binaries. These SFP binaries can overlap in angular separation with the regime of systems resolvable by speckle interferometry at single, large-aperture telescopes and can provide additional measurements for preliminary orbits lacking good phase coverage, help constrain elements of already established orbits, and locate new binaries in the undersampled regime between the bounds of spectroscopic surveys and speckle interferometry. In this process, a visibility calibration star is not needed, and themore » SFPs can provide an accurate vector separation. In this paper, we apply the SFP approach to ω Andromeda, HD 178911, and ξ Cephei with the CLIMB three-beam combiner at the CHARA Array. For these systems we determine component masses and parallax of 0.963 ± 0.049 M {sub ☉} and 0.860 ± 0.051 M {sub ☉} and 39.54 ± 1.85 mas for ω Andromeda, for HD 178911 of 0.802 ± 0.055 M {sub ☉} and 0.622 ± 0.053 M {sub ☉} with 28.26 ± 1.70 mas, and masses of 1.045 ± 0.031 M {sub ☉} and 0.408 ± 0.066 M {sub ☉} and 38.10 ± 2.81 mas for ξ Cephei.« less
NASA Astrophysics Data System (ADS)
Avadhut, Yamini S.; Weber, Johannes; Schmedt auf der Günne, Jörn
2017-09-01
An improved implementation of single-crystal magic-angle-spinning (MAS) NMR is presented which gives access to chemical shift tensors both in orientation (relative to the crystal axis system) and principal axis values. For mounting arbitrary crystals inside ordinary MAS rotors, a mounting tool is described which allows to relate the crystal orientation determined by diffraction techniques to the rotor coordinate system. The crystal is finally mounted into a MAS rotor equipped with a special insert which allows a defined reorientation of the single-crystal by 90°. The approach is based on the idea that the dispersive spectra, which are obtained when applying read-pulses at specific rotor-phases, not only yield the size of the eigenvalues but also encode the orientation of the different chemical shift (rank-2) tensors. For this purpose two 2D-data sets with orthogonal crystal orientation are fitted simultaneously. The presented analysis for chemical shift tensors is supported by an analytical formula which allows fast calculation of phase and amplitude of individual spinning side-bands and by a protocol which solves the problem of finding the correct reference phase of the spectrum. Different rotor-synchronized pulse-sequences are introduced for the same reason. Experiments are performed on L-alanine and O-phosphorylethanolamine and the observed errors are analyzed in detail. The experimental data are opposed to DFT-computed chemical shift tensors which have been obtained by the extended embedded ion method.
Heyne, J P; Merbold, H; Sehner, J; Neumann, R; Freesmeyer, M; Jonetz-Mentzel, L; Kaiser, W A
1999-07-01
How much can the radiation dose be reduced for skull radiography by using digital luminescence radiography (DLR) compared to a conventional screen film system with a grid cassette? A skull phantom (3M) was x-rayed in anterior-posterior orientation using both a conventional screen film system with grid cassette and DLR (ADC-70, Agfa). The tube current time product (mAs) was diminished gradually while keeping the voltage constant. The surface entrance dose was measured by a sensor of Dosimax (Wellhöfer). Five investigators evaluated the images by characteristic and critical features, spatial resolution and contrast. The surface entrance dose at 73 kV/22 mAs was 0.432 mGy in conventional screen film system and 0.435 mGy in DLR. The images could be evaluated very well down to an average dose of 71% (0.308 mGy; SD 0.050); sufficient images were obtained down to an average dose of 31% (0.136 mGy; SD 0.065). The resolution of the line pairs were reduced down to 2 levels depending on the investigator. Contrast was assessed as being very good to sufficient. The acceptance of the postprocessed images (MUSICA-software) was individually different and resulted in an improvement of the assessment of bone structures and contrast in higher dose ranges only. For the sufficient assessment of a possible fracture/of paranasal sinuses/of measurement of the skull the dose can be reduced to at least 56% (phi 31%; SD 14.9%)/40% (phi 27%; SD 9.3%)/18% (phi 14%; SD 4.4%). Digital radiography allows question-referred exposure parameters with clearly reduced dose, so e.g. for fracture exclusion 73 kV/12.5 mAs and to skull measurement 73 kV/4 mAs.
Suntharalingam, Saravanabavaan; Mikat, Christian; Stenzel, Elena; Erfanian, Youssef; Wetter, Axel; Schlosser, Thomas; Forsting, Michael; Nassenstein, Kai
2017-01-01
To evaluate the image quality and radiation dose of submillisievert standard-pitch CT pulmonary angiography (CTPA) with ultra-low dose contrast media administration in comparison to standard CTPA. Hundred patients (56 females, 44 males, mean age 69.6±15.4 years; median BMI: 26.6, IQR: 5.9) with suspected pulmonary embolism were examined with two different protocols (n = 50 each, group A: 80 kVp, ref. mAs 115, 25 ml of contrast medium; group B: 100 kVp, ref. mAs 150, 60 ml of contrast medium) using a dual-source CT equipped with automated exposure control. Objective and subjective image qualities, radiation exposure as well as the frequency of pulmonary embolism were evaluated. There was no significant difference in subjective image quality scores between two groups regarding pulmonary arteries (p = 0.776), whereby the interobserver agreement was excellent (group A: k = 0.9; group B k = 1.0). Objective image analysis revealed that signal intensities (SI), signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the pulmonary arteries were equal or significantly higher in group B. There was no significant difference in the frequency of pulmonary embolism (p = 0.65). Using the low dose and low contrast media protocol resulted in a radiation dose reduction by 71.8% (2.4 vs. 0.7 mSv; p<0.001). This 80 kVp standard pitch CTPA protocol with 25 ml contrast agent volume can obtain sufficient image quality to exclude or diagnose pulmonary emboli while reducing radiation dose by approximately 71%.
Hydronephrosis alters cardiac ACE2 and Mas receptor expression in mice.
Zhang, Yanling; Ma, Lulu; Wu, Junyan; Chen, Tingting
2015-06-01
Hydronephrosis is characterized by substantial loss of tubules and affects renin secretion in the kidney. However, whether alterations of angiotensin-converting enzyme (ACE), ACE2 and Mas receptor in the heart are observed in hydronephrosis is unknown. Thus, we assessed these components in hydronephrotic mice treated with AT1 receptor blockade and ACE inhibitor. Hydronephrosis was induced by left ureteral ligation in Balb/C mice except sham-operated animals. The levels of cardiac ACE, ACE2 and Mas receptor were measured after treatment of losartan or enalapril. Hydronephrosis led to an increase of ACE level and a decrease of ACE2 and Mas receptor in the heart. Losartan decreased cardiac ACE level, but ACE2 and Mas receptor levels significantly increased in hydronephrotic mice (p < 0.01). Enalapril increased ACE2 levels (p < 0.01), but did not affect Mas receptor in the heart. Plasma renin activity (PRA) and Ang II decreased in hydronephrotic mice, but significantly increased after treatment with losartan or enalapril. Hydronephrosis increased cardiac ACE and suppressed ACE2 and Mas receptor levels. AT1 blockade caused sustained activation of cardiac ACE2 and Mas receptor, but ACE inhibitor had the limitation of such activation of Mas receptor in hydronephrotic animals. © The Author(s) 2015.
González-Mohíno, Fernando; González-Ravé, José M; Juárez, Daniel; Fernández, Francisco A; Barragán Castellanos, Rubén; Newton, Robert U
2016-04-01
The purpose of this study was to evaluate the effects on running economy (RE), V[Combining Dot Above]O2max, maximal aerobic speed (MAS), and gait kinematics (step length [SL] and frequency, flight and contact time [CT]) in recreational athletes, with 2 different training methods, Interval and Continuous (CON). Eleven participants were randomly distributed in an interval training group (INT; n = 6) or CON training group (CON; n = 5). Interval training and CON performed 2 different training programs (95-110% and 70-75% of MAS, respectively), which consisted of 3 sessions per week during 6 weeks with the same external workload (%MAS × duration). An incremental test to exhaustion was performed to obtain V[Combining Dot Above]O2max, MAS, RE, and gait variables (high speed camera) before and after the training intervention. There was a significant improvement (p ≤ 0.05) in RE at 60 and 90% of MAS by the CON group; without changes in gait. The INT group significantly increased MAS and higher stride length at 80, 90, and 100% of MAS and lower CT at 100% of MAS. As expected, training adaptations are highly specific to the overload applied with CON producing improvements in RE at lower percentage of MAS whereas INT produces improvements in MAS. The significantly increased stride length and decreased CT for the INT group are an important outcome of favorable changes in running gait.
Fluid flow dynamics in MAS systems
NASA Astrophysics Data System (ADS)
Wilhelm, Dirk; Purea, Armin; Engelke, Frank
2015-08-01
The turbine system and the radial bearing of a high performance magic angle spinning (MAS) probe with 1.3 mm-rotor diameter has been analyzed for spinning rates up to 67 kHz. We focused mainly on the fluid flow properties of the MAS system. Therefore, computational fluid dynamics (CFD) simulations and fluid measurements of the turbine and the radial bearings have been performed. CFD simulation and measurement results of the 1.3 mm-MAS rotor system show relatively low efficiency (about 25%) compared to standard turbo machines outside the realm of MAS. However, in particular, MAS turbines are mainly optimized for speed and stability instead of efficiency. We have compared MAS systems for rotor diameter of 1.3-7 mm converted to dimensionless values with classical turbomachinery systems showing that the operation parameters (rotor diameter, inlet mass flow, spinning rate) are in the favorable range. This dimensionless analysis also supports radial turbines for low speed MAS probes and diagonal turbines for high speed MAS probes. Consequently, a change from Pelton type MAS turbines to diagonal turbines might be worth considering for high speed applications. CFD simulations of the radial bearings have been compared with basic theoretical values proposing considerably smaller frictional loss values. The discrepancies might be due to the simple linear flow profile employed for the theoretical model. Frictional losses generated inside the radial bearings result in undesired heat-up of the rotor. The rotor surface temperature distribution computed by CFD simulations show a large temperature gradient over the rotor.
Ravelli, Angelo; Minoia, Francesca; Davì, Sergio; Horne, AnnaCarin; Bovis, Francesca; Pistorio, Angela; Aricò, Maurizio; Avcin, Tadej; Behrens, Edward M; De Benedetti, Fabrizio; Filipovic, Lisa; Grom, Alexei A; Henter, Jan-Inge; Ilowite, Norman T; Jordan, Michael B; Khubchandani, Raju; Kitoh, Toshiyuki; Lehmberg, Kai; Lovell, Daniel J; Miettunen, Paivi; Nichols, Kim E; Ozen, Seza; Pachlopnik Schmid, Jana; Ramanan, Athimalaipet V; Russo, Ricardo; Schneider, Rayfel; Sterba, Gary; Uziel, Yosef; Wallace, Carol; Wouters, Carine; Wulffraat, Nico; Demirkaya, Erkan; Brunner, Hermine I; Martini, Alberto; Ruperto, Nicolino; Cron, Randy Q
2016-03-01
To develop criteria for the classification of macrophage activation syndrome (MAS) in patients with systemic juvenile idiopathic arthritis (JIA). A multistep process, based on a combination of expert consensus and analysis of real patient data, was conducted. A panel of 28 experts was first asked to classify 428 patient profiles as having or not having MAS, based on clinical and laboratory features at the time of disease onset. The 428 profiles comprised 161 patients with systemic JIA-associated MAS and 267 patients with a condition that could potentially be confused with MAS (active systemic JIA without evidence of MAS, or systemic infection). Next, the ability of candidate criteria to classify individual patients as having MAS or not having MAS was assessed by evaluating the agreement between the classification yielded using the criteria and the consensus classification of the experts. The final criteria were selected in a consensus conference. Experts achieved consensus on the classification of 391 of the 428 patient profiles (91.4%). A total of 982 candidate criteria were tested statistically. The 37 best-performing criteria and 8 criteria obtained from the literature were evaluated at the consensus conference. During the conference, 82% consensus among experts was reached on the final MAS classification criteria. In validation analyses, these criteria had a sensitivity of 0.73 and a specificity of 0.99. Agreement between the classification (MAS or not MAS) obtained using the criteria and the original diagnosis made by the treating physician was high (κ = 0.76). We have developed a set of classification criteria for MAS complicating systemic JIA and provided preliminary evidence of its validity. Use of these criteria will potentially improve understanding of MAS in systemic JIA and enhance efforts to discover effective therapies, by ensuring appropriate patient enrollment in studies. © 2015, American College of Rheumatology.
Aytaç, Selin; Batu, Ezgi Deniz; Ünal, Şule; Bilginer, Yelda; Çetin, Mualla; Tuncer, Murat; Gümrük, Fatma; Özen, Seza
2016-10-01
Macrophage activation syndrome (MAS) is a hyper-inflammatory disorder secondary to a rheumatic disease such as systemic juvenile idiopathic arthritis (SJIA) and systemic lupus erythematosus (SLE). We aimed to present the characteristics of our pediatric MAS patients. Clinical features, laboratory parameters, treatment, and outcome of 34 patients (28 SJIA; six SLE; 37 MAS episodes) followed at a tertiary health center between 2009 and 2015 were retrospectively reviewed. The median age at MAS onset was 11 years. More SJIA patients had MAS at disease onset than SLE patients (53.6 vs. 16.7 %). Fever, high C-reactive protein and hyperferritinemia were present in all MAS episodes. Rash was less (p = 0.03), and fatigue was more frequent (p = 0.042) in SLE than SJIA patients. All received corticosteroids. Cyclosporine was given in 74.2 % of SJIA-MAS; 66.7 % of SLE-MAS episodes. Intravenous immunoglobulin, anakinra, or etoposide was administered during 67.7; 41.9; 32.3 % of SJIA-MAS and 33.3; 33.3; 50 % of SLE-MAS episodes, respectively. Plasmapheresis was performed during 41.9 % of SJIA-MAS and 33.3 % of SLE-MAS episodes. The mortality rate was 11.8 % (n = 4;3 SJIA, 1 SLE). Hepatosplenomegaly was more frequent (p = 0.005), and plasmapheresis was performed more frequently (p = 0.021) in the patients who died compared to the cured patients. The median duration between symptom onset and admission to our hospital was longer among the patients who died (16.5 vs. 7 days; p = 0.049). Our patients' characteristics were similar to the reported cases, but our mortality rate is slightly higher probably due to late referral to our center. Early diagnosis and effective treatment are crucial to prevent mortality.
Gettings, S D; Lordo, R A; Hintze, K L; Bagley, D M; Casterton, P L; Chudkowski, M; Curren, R D; Demetrulias, J L; Dipasquale, L C; Earl, L K; Feder, P I; Galli, C L; Glaza, S M; Gordon, V C; Janus, J; Kurtz, P J; Marenus, K D; Moral, J; Pape, W J; Renskers, K J; Rheins, L A; Roddy, M T; Rozen, M G; Tedeschi, J P; Zyracki, J
1996-01-01
The CTFA Evaluation of Alternatives Program is an evaluation of the relationship between data from the Draize primary eye irritation test and comparable data from a selection of promising in vitro eye irritation tests. In Phase III, data from the Draize test and 41 in vitro endpoints on 25 representative surfactant-based personal care formulations were compared. As in Phase I and Phase II, regression modelling of the relationship between maximum average Draize score (MAS) and in vitro endpoint was the primary approach adopted for evaluating in vitro assay performance. The degree of confidence in prediction of MAS for a given in vitro endpoint is quantified in terms of the relative widths of prediction intervals constructed about the fitted regression curve. Prediction intervals reflect not only the error attributed to the model but also the material-specific components of variation in both the Draize and the in vitro assays. Among the in vitro assays selected for regression modeling in Phase III, the relationship between MAS and in vitro score was relatively well defined. The prediction bounds on MAS were most narrow for materials at the lower or upper end of the effective irritation range (MAS = 0-45), where variability in MAS was smallest. This, the confidence with which the MAS of surfactant-based formulations is predicted is greatest when MAS approaches zero or when MAS approaches 45 (no comment is made on prediction of MAS > 45 since extrapolation beyond the range of observed data is not possible). No single in vitro endpoint was found to exhibit relative superiority with regard to prediction of MAS. Variability associated with Draize test outcome (e.g. in MAS values) must be considered in any future comparisons of in vivo and in vitro test results if the purpose is to predict in vivo response using in vitro data.
Sefsafi, Zakia; Hasbaoui, Brahim El; Kili, Amina; Agadr, Aomar; Khattab, Mohammed
2018-01-01
Abstract Macrophage activation syndrome (MAS) is a severe and potentially fatal life-threatening condition associated with excessive activation and expansion of T cells with macrophages and a high expression of cytokines, resulting in an uncontrolled inflammatory response, with high levels of macrophage colony-stimulating factor and causing multiorgan damage. This syndrome is classified into primary (genetic/familial) or secondary forms to several etiologies, such as infections, neoplasias mainly hemopathies or autoimmune diseases. It is characterised clinically by unremitting high fever, pancytopaenia, hepatosplenomegaly, hepatic dysfunction, encephalopathy, coagulation abnormalities and sharply increased levels of ferritin. The pathognomonic feature of the syndrome is seen on bone marrow examination, which frequently, though not always, reveals numerous morphologically benign macrophages exhibiting haemophagocytic activity. Because MAS can follow a rapidly fatal course, prompt recognition of its clinical and laboratory features and immediate therapeutic intervention are essential. However, it is difficult to distinguish underlying disease flare, infectious complications or medication side effects from MAS. Although, the pathogenesis of MAS is unclear, the hallmark of the syndrome is an uncontrolled activation and proliferation of T lymphocytes and macrophages, leading to massive hypersecretion of pro-inflammatory cytokines. Mutations in cytolytic pathway genes are increasingly being recognised in children who develop MAS in his secondary form. We present here a case of Macrophage activation syndrome associated with Griscelli syndrome type 2 in a 3-years-old boy who had been referred due to severe sepsis with non-remitting high fever, generalized lymphoadenopathy and hepato-splenomegaly. Laboratory data revealed pancytopenia with high concentrations of triglycerides, ferritin and lactic dehydrogenase while the bone marrow revealed numerous morphologically benign macrophages with haemophagocytic activity that comforting the diagnosis of a SAM according to Ravelli and HLH-2004 criteria. Griscelli syndrome (GS) was evoked on; consanguineous family, recurrent infection, very light silvery-gray color of the hair and eyebrows, Light microscopy examination of the hair showed large, irregular clumps of pigments characteristic of GS. The molecular biology showed mutation in RAB27A gene confirming the diagnosis of a Griscelli syndrome type 2. The first-line therapy was based on the parenteral administration of high doses of corticosteroids, associated with immunosuppressive drugs, cyclosporine A and etoposide waiting for bone marrow transplantation (BMT). PMID:29875956
SU-F-18C-06: Prospective Patient Evaluation of Iterative Reconstruction in Radiation Oncology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Price, R; Vance, S; Cattaneo, R
2014-06-15
Purpose: This work incorporates iterative reconstruction (IR) into a dose reduction study to characterize image quality metrics, delineation, and dosimetric assessment, with the goal of reducing imaging dose in Radiation Oncology. Methods: Three-dimensional noise power spectrum (NPS) analysis characterized noise magnitude/texture (120 kVp, 50–200 mAs, IR levels 1–6 yielding noise reduction of 0.89–0.55 compared to filtered backprojection (FBP)). Task-specific Modulation Transfer Functions (MTFtask) were characterized across varied subject contrasts. A prospective dose reduction study (500 to 150 mAs) was conducted for 12 patients (43 inter-fraction CTs) for high-dose rate brachytherapy. Three physicians performed qualitative image assessment between full-dose FBP (FD-FBP,more » 500 mAs), low-dose FBP (LD-FBP, 150–250 mAs), and low-dose IRL5-6 (LD-IR) scans for image noise, cuff/bladder interface detectability, spatial resolution, texture, and segmentation confidence. Comparisons between LD-FBP and LD-IR were conducted for the following metrics: delineation (bladder and rectum evaluated via overlap indices (OI) and Dice similarity coefficients (DSC)), noise, boundary changes, dose calculation, and digitally reconstructed radiographs (DRRs). Results: NPS showed ∼50% reduction in noise magnitude and ∼0.1 1/mm spatial frequency shift with IRL6. The largest MTFtask decrease between FBP and IR was 0.08 A.U. Qualitative patient image evaluation revealed LD-IR was equivalent or slightly worse than FD-FBP, and superior to LD-FBP for all metrics except low contrast interface and texture. The largest CT number discrepancy from FBP occurred at a bone/tissue interface using IRL6 (−1.2 ± 4.9 HU (range: −17.6 – 12.5 HU)). No significant contour differences (OIs and DSCs = 0.85 – 0.95) and dose calculation discrepancy (<0.02%) were observed. DRRs preserved anatomical detail and demonstrated <2% difference in intensity between LD-FBP and LD-IRL6. Conclusion: While phantom analysis showed slight noise texture differences with IR, patient results revealed that image quality, contouring ability, and dosimetric parameters were not adversely affected, thus support integrating IR into treatment planning. Research supported in part by a grant from Philips HealthCare.« less
Further conventions for NMR shielding and chemical shifts IUPAC recommendations 2008.
Harris, Robin K; Becker, Edwin D; Cabral De Menezes, Sonia M; Granger, Pierre; Hoffman, Roy E; Zilm, Kurt W
2008-03-01
IUPAC has published a number of recommendations regarding the reporting of nuclear magnetic resonance (NMR) data, especially chemical shifts. The most recent publication [Pure Appl. Chem. 73, 1795 (2001)] recommended that tetramethylsilane (TMS) serve as a universal reference for reporting the shifts of all nuclides, but it deferred recommendations for several aspects of this subject. This document first examines the extent to which the (1)H shielding in TMS itself is subject to change by variation in temperature, concentration, and solvent. On the basis of recently published results, it has been established that the shielding of TMS in solution [along with that of sodium-3-(trimethylsilyl)propanesulfonate, DSS, often used as a reference for aqueous solutions] varies only slightly with temperature but is subject to solvent perturbations of a few tenths of a part per million (ppm). Recommendations are given for reporting chemical shifts under most routine experimental conditions and for quantifying effects of temperature and solvent variation, including the use of magnetic susceptibility corrections and of magic-angle spinning (MAS). This document provides the first IUPAC recommendations for referencing and reporting chemical shifts in solids, based on high-resolution MAS studies. Procedures are given for relating (13)C NMR chemical shifts in solids to the scales used for high-resolution studies in the liquid phase. The notation and terminology used for describing chemical shift and shielding tensors in solids are reviewed in some detail, and recommendations are given for best practice.
Further conventions for NMR shielding and chemical shifts (IUPAC Recommendations 2008).
Harris, Robin K; Becker, Edwin D; De Menezes, Sonia M Cabral; Granger, Pierre; Hoffman, Roy E; Zilm, Kurt W
2008-06-01
IUPAC has published a number of recommendations regarding the reporting of nuclear magnetic resonance (NMR) data, especially chemical shifts. The most recent publication [Pure Appl. Chem. 73, 1795 (2001)] recommended that tetramethylsilane (TMS) serve as a universal reference for reporting the shifts of all nuclides, but it deferred recommendations for several aspects of this subject. This document first examines the extent to which the (1)H shielding in TMS itself is subject to change by variation in temperature, concentration, and solvent. On the basis of recently published results, it has been established that the shielding of TMS in solution [along with that of sodium-3-(trimethylsilyl)propanesulfonate, DSS, often used as a reference for aqueous solutions] varies only slightly with temperature but is subject to solvent perturbations of a few tenths of a part per million (ppm). Recommendations are given for reporting chemical shifts under most routine experimental conditions and for quantifying effects of temperature and solvent variation, including the use of magnetic susceptibility corrections and of magic-angle spinning (MAS). This document provides the first IUPAC recommendations for referencing and reporting chemical shifts in solids, based on high-resolution MAS studies. Procedures are given for relating (13)C NMR chemical shifts in solids to the scales used for high-resolution studies in the liquid phase. The notation and terminology used for describing chemical shift and shielding tensors in solids are reviewed in some detail, and recommendations are given for best practice. Copyright (c) 2008 John Wiley & Sons, Ltd
Very Long Baseline Array Astrometric Observations of the Cassini Spacecraft at Saturn
NASA Astrophysics Data System (ADS)
Jones, Dayton L.; Fomalont, Ed; Dhawan, Vivek; Romney, Jon; Folkner, William M.; Lanyi, Gabor; Border, James; Jacobson, Robert A.
2011-02-01
The planetary ephemeris is an essential tool for interplanetary spacecraft navigation, studies of solar system dynamics (including, for example, barycenter corrections for pulsar timing ephemerides), the prediction of occultations, and tests of general relativity. We are carrying out a series of astrometric very long baseline interferometry observations of the Cassini spacecraft currently in orbit around Saturn, using the Very Long Baseline Array (VLBA). These observations provide positions for the center of mass of Saturn in the International Celestial Reference Frame (ICRF) with accuracies ~0.3 mas (1.5 nrad) or about 2 km at the average distance of Saturn. This paper reports results from eight observing epochs between 2006 October and 2009 April. These data are combined with two VLBA observations by other investigators in 2004 and a Cassini-based gravitational deflection measurement by Fomalont et al. in 2009 to constrain a new ephemeris (DE 422). The DE 422 post-fit residuals for Saturn with respect to the VLBA data are generally 0.2 mas, but additional observations are needed to improve the positions of all of our phase reference sources to this level. Over time we expect to be able to improve the accuracy of all three coordinates in the Saturn ephemeris (latitude, longitude, and range) by a factor of at least three. This will represent a significant improvement not just in the Saturn ephemeris but also in the link between the inner and outer solar system ephemerides and in the link to the inertial ICRF.
2010-01-01
In July 2009, the Medical Advisory Secretariat (MAS) began work on Non-Invasive Cardiac Imaging Technologies for the Diagnosis of Coronary Artery Disease (CAD), an evidence-based review of the literature surrounding different cardiac imaging modalities to ensure that appropriate technologies are accessed by patients suspected of having CAD. This project came about when the Health Services Branch at the Ministry of Health and Long-Term Care asked MAS to provide an evidentiary platform on effectiveness and cost-effectiveness of non-invasive cardiac imaging modalities.After an initial review of the strategy and consultation with experts, MAS identified five key non-invasive cardiac imaging technologies for the diagnosis of CAD. Evidence-based analyses have been prepared for each of these five imaging modalities: cardiac magnetic resonance imaging, single photon emission computed tomography, 64-slice computed tomographic angiography, stress echocardiography, and stress echocardiography with contrast. For each technology, an economic analysis was also completed (where appropriate). A summary decision analytic model was then developed to encapsulate the data from each of these reports (available on the OHTAC and MAS website).The Non-Invasive Cardiac Imaging Technologies for the Diagnosis of Coronary Artery Disease series is made up of the following reports, which can be publicly accessed at the MAS website at: www.health.gov.on.ca/mas or at www.health.gov.on.ca/english/providers/program/mas/mas_about.htmlSINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY FOR THE DIAGNOSIS OF CORONARY ARTERY DISEASE: An Evidence-Based AnalysisSTRESS ECHOCARDIOGRAPHY FOR THE DIAGNOSIS OF CORONARY ARTERY DISEASE: An Evidence-Based AnalysisSTRESS ECHOCARDIOGRAPHY WITH CONTRAST FOR THE DIAGNOSIS OF CORONARY ARTERY DISEASE: An Evidence-Based Analysis64-Slice Computed Tomographic Angiography for the Diagnosis of Coronary Artery Disease: An Evidence-Based AnalysisCARDIAC MAGNETIC RESONANCE IMAGING FOR THE DIAGNOSIS OF CORONARY ARTERY DISEASE: An Evidence-Based AnalysisPease note that two related evidence-based analyses of non-invasive cardiac imaging technologies for the assessment of myocardial viability are also available on the MAS website:POSITRON EMISSION TOMOGRAPHY FOR THE ASSESSMENT OF MYOCARDIAL VIABILITY: An Evidence-Based AnalysisMAGNETIC RESONANCE IMAGING FOR THE ASSESSMENT OF MYOCARDIAL VIABILITY: an Evidence-Based AnalysisThe Toronto Health Economics and Technology Assessment Collaborative has also produced an associated economic report entitled:The Relative Cost-effectiveness of Five Non-invasive Cardiac Imaging Technologies for Diagnosing Coronary Artery Disease in Ontario [Internet]. Available from: http://theta.utoronto.ca/reports/?id=7 OBJECTIVE: The objective of this analysis was to determine the diagnostic accuracy of cardiac magnetic resonance imaging (MRI) for the diagnosis of patients with known/suspected coronary artery disease (CAD) compared to coronary angiography. Stress cardiac MRI is a non-invasive, x-ray free imaging technique that takes approximately 30 to 45 minutes to complete and can be performed using to two different methods, a) perfusion imaging following a first pass of an intravenous bolus of gadolinium contrast, or b) wall motion imaging. Stress is induced pharmacologically with either dobutamine, dipyridamole, or adenosine, as physical exercise is difficult to perform within the magnet bore and often induces motion artifacts. Alternatives to stress cardiac perfusion MRI include stress single-photon emission computed tomography (SPECT) and stress echocardiography (ECHO). The advantage of cardiac MRI is that it does not pose the radiation burden associated with SPECT. During the same sitting, cardiac MRI can also assess left and right ventricular dimensions, viability, and cardiac mass. It may also mitigate the need for invasive diagnostic coronary angiography in patients with intermediate risk factors for CAD. EVIDENCE-BASED ANALYSIS: A literature search was performed on October 9, 2009 using OVID MEDLINE, MEDLINE In-Process and Other Non-Indexed Citations, EMBASE, the Cumulative Index to Nursing & Allied Health Literature (CINAHL), the Cochrane Library, and the International Agency for Health Technology Assessment (INAHTA) for studies published from January 1, 2005 to October 9, 2008. Abstracts were reviewed by a single reviewer and, for those studies meeting the eligibility criteria, full-text articles were obtained. Reference lists were also examined for any relevant studies not identified through the search. Articles with unknown eligibility were reviewed with a second clinical epidemiologist and then a group of epidemiologists until consensus was established. The quality of evidence was assessed as high, moderate, low or very low according to GRADE methodology. Given the large amount of clinical heterogeneity of the articles meeting the inclusion criteria, as well as suggestions from an Expert Advisory Panel Meeting held on October 5, 2009, the inclusion criteria were revised to examine the effectiveness of cardiac MRI for the detection of CAD. Inclusion CriteriaExclusion CriteriaHeath technology assessments, systematic reviews, randomized controlled trials, observational studies≥20 adult patients enrolled.Published 2004-2009Licensed by Health CanadaFor diagnosis of CAD:Reference standard is coronary angiographySignificant CAD defined as ≥ 50% coronary stenosisPatients with suspected or known CADReported results by patient, not segmentNon-English studiesGrey literaturePlanar imagingMUGAPatients with recent MI (i.e., within 1 month)Patients with non-ischemic heart diseaseStudies done exclusively in special populations (e.g., women, diabetics) Sensitivity and specificityArea under the curve (AUC)Diagnostic odds ratio (DOR) SUMMARY OF FINDINGS: Stress cardiac MRI using perfusion analysis yielded a pooled sensitivity of 0.91 (95% CI: 0.89 to 0.92) and specificity of 0.79 (95% CI: 0.76 to 0.82) for the detection of CAD.Stress cardiac MRI using wall motion analysis yielded a pooled sensitivity of 0.81 (95% CI: 0.77 to 0.84) and specificity of 0.85 (95% CI: 0.81 to 0.89) for the detection of CAD.Based on DORs, there was no significant difference between pooled stress cardiac MRI using perfusion analysis and pooled stress cardiac MRI using wall motion analysis (P=0.26) for the detection of CAD.Pooled subgroup analysis of stress cardiac MRI using perfusion analysis showed no significant difference in the DORs between 1.5T and 3T MRI (P=0.72) for the detection of CAD.One study (N=60) was identified that examined stress cardiac MRI using wall motion analysis with a 3T MRI. The sensitivity and specificity of 3T MRI were 0.64 (95% CI: 0.44 to 0.81) and 1.00 (95% CI: 0.89 to 1.00), respectively, for the detection of CAD.The effectiveness of stress cardiac MRI for the detection of CAD in unstable patients with acute coronary syndrome was reported in only one study (N=35). Using perfusion analysis, the sensitivity and specificity were 0.72 (95% CI: 0.53 to 0.87) and 1.00 (95% CI: 0.54 to 1.00), respectively, for the detection of CAD. According to an expert consultant, in Ontario: Stress first pass perfusion is currently performed in small numbers in London (London Health Sciences Centre) and Toronto (University Health Network at the Toronto General Hospital site and Sunnybrook Health Sciences Centre).Stress wall motion is only performed as part of research protocols and not very often.Cardiac MRI machines use 1.5T almost exclusively, with 3T used in research for first pass perfusion.On November 25 2009, the Cardiac Imaging Expert Advisory Panel met and made the following comments about stress cardiac MRI for perfusion analysis: Accessibility to cardiac MRI is limited and generally used to assess structural abnormalities. Most MRIs in Ontario are already in 24-hour, constant use and it would thus be difficult to add cardiac MRI for CAD diagnosis as an additional indication.The performance of cardiac MRI for the diagnosis of CAD can be technically challenging. The quality of the body of evidence was assessed according to the GRADE Working Group criteria for diagnostic tests. For perfusion analysis, the overall quality was determined to be low and for wall motion analysis the overall quality was very low.
Fluid flow dynamics in MAS systems.
Wilhelm, Dirk; Purea, Armin; Engelke, Frank
2015-08-01
The turbine system and the radial bearing of a high performance magic angle spinning (MAS) probe with 1.3mm-rotor diameter has been analyzed for spinning rates up to 67kHz. We focused mainly on the fluid flow properties of the MAS system. Therefore, computational fluid dynamics (CFD) simulations and fluid measurements of the turbine and the radial bearings have been performed. CFD simulation and measurement results of the 1.3mm-MAS rotor system show relatively low efficiency (about 25%) compared to standard turbo machines outside the realm of MAS. However, in particular, MAS turbines are mainly optimized for speed and stability instead of efficiency. We have compared MAS systems for rotor diameter of 1.3-7mm converted to dimensionless values with classical turbomachinery systems showing that the operation parameters (rotor diameter, inlet mass flow, spinning rate) are in the favorable range. This dimensionless analysis also supports radial turbines for low speed MAS probes and diagonal turbines for high speed MAS probes. Consequently, a change from Pelton type MAS turbines to diagonal turbines might be worth considering for high speed applications. CFD simulations of the radial bearings have been compared with basic theoretical values proposing considerably smaller frictional loss values. The discrepancies might be due to the simple linear flow profile employed for the theoretical model. Frictional losses generated inside the radial bearings result in undesired heat-up of the rotor. The rotor surface temperature distribution computed by CFD simulations show a large temperature gradient over the rotor. Copyright © 2015 Elsevier Inc. All rights reserved.
The Gα o Activator Mastoparan-7 Promotes Dendritic Spine Formation in Hippocampal Neurons
Ramírez, Valerie T.; Ramos-Fernández, Eva; Inestrosa, Nibaldo C.
2016-01-01
Mastoparan-7 (Mas-7), an analogue of the peptide mastoparan, which is derived from wasp venom, is a direct activator of Pertussis toxin- (PTX-) sensitive G proteins. Mas-7 produces several biological effects in different cell types; however, little is known about how Mas-7 influences mature hippocampal neurons. We examined the specific role of Mas-7 in the development of dendritic spines, the sites of excitatory synaptic contact that are crucial for synaptic plasticity. We report here that exposure of hippocampal neurons to a low dose of Mas-7 increases dendritic spine density and spine head width in a time-dependent manner. Additionally, Mas-7 enhances postsynaptic density protein-95 (PSD-95) clustering in neurites and activates Gα o signaling, increasing the intracellular Ca2+ concentration. To define the role of signaling intermediates, we measured the levels of phosphorylated protein kinase C (PKC), c-Jun N-terminal kinase (JNK), and calcium-calmodulin dependent protein kinase IIα (CaMKIIα) after Mas-7 treatment and determined that CaMKII activation is necessary for the Mas-7-dependent increase in dendritic spine density. Our results demonstrate a critical role for Gα o subunit signaling in the regulation of synapse formation. PMID:26881110
Measurements of eight early-type stars angular diameters using VEGA/CHARA interferometer
NASA Astrophysics Data System (ADS)
Challouf, M.; Nardetto, N.; Mourard, D.; Aroui, H.; Delaa, O.
2014-12-01
The surface brightness color (SBC) relation is an important tool to derive the distance of extragalatic eclipsing binaries. We determined the uniform disc angular diameter of the eight following early-type stars using VEGA/CHARA interferometric observations: θ_{UD}[δ Cyg] = 0.766 ± 0.047 mas, θ_{UD}[γ Lyr] = 0.742& ± 0.010 mas, θ_{UD}[γ Ori] = 0.701 ± 0.005 mas, θ_{UD}[ζ Peg] = 0.539 ± 0.009 mas, θ_{UD}[λ Aql] = 0.529 ± 0.003 mas, θ_{UD}[ζ Per] = 0.531 ± 0.007 mas, θ_{UD}[ι Her] = 0.304 ± 0.010 mas and θ_{UD}[8 Cyg] = 0.229 ± 0.011 mas (by extending V-K range from -0.76 to 0.02) with typical precision of about 1.5%. By combining these data with previous angular diameter determinations available in the literature, Challouf et al. (2014) provide for the very first time a SBC relation for early-type stars (-1≤V-K≤0) with a precision of about 0.16 magnitude or 7% in term of angular diameter (when using this SBC relation to derive the angular diameter of early-type stars).
The Gαo Activator Mastoparan-7 Promotes Dendritic Spine Formation in Hippocampal Neurons.
Ramírez, Valerie T; Ramos-Fernández, Eva; Inestrosa, Nibaldo C
2016-01-01
Mastoparan-7 (Mas-7), an analogue of the peptide mastoparan, which is derived from wasp venom, is a direct activator of Pertussis toxin- (PTX-) sensitive G proteins. Mas-7 produces several biological effects in different cell types; however, little is known about how Mas-7 influences mature hippocampal neurons. We examined the specific role of Mas-7 in the development of dendritic spines, the sites of excitatory synaptic contact that are crucial for synaptic plasticity. We report here that exposure of hippocampal neurons to a low dose of Mas-7 increases dendritic spine density and spine head width in a time-dependent manner. Additionally, Mas-7 enhances postsynaptic density protein-95 (PSD-95) clustering in neurites and activates Gα(o) signaling, increasing the intracellular Ca(2+) concentration. To define the role of signaling intermediates, we measured the levels of phosphorylated protein kinase C (PKC), c-Jun N-terminal kinase (JNK), and calcium-calmodulin dependent protein kinase IIα (CaMKIIα) after Mas-7 treatment and determined that CaMKII activation is necessary for the Mas-7-dependent increase in dendritic spine density. Our results demonstrate a critical role for Gα(o) subunit signaling in the regulation of synapse formation.
Kraus, Tanja; Gegenleitner, Kathrin; Svehlik, Martin; Novak, Michael; Steinwender, Gerhardt; Singer, Georg
2017-05-01
Children with severe spastic cerebral palsy (CP) are highly limited in daily life activities causing a reduced quality of life (QoL). This is partly due to an increased muscle tone causing pain and contractures. Continuous intrathecal infusion of baclofen (ITB) reduces the spasticity of affected patients. The hypothesis of the present study was that ITB leads to a significant improvement of QoL in non-ambulant children with CP. 13 patients (10 male, 3 female, mean age 14 years) were included. Mean time between pump implantation and follow-up was 60 months (range, 12-100). QoL was assessed before and after baclofen pump implantation using standardized questionnaires (CP CHILD, KINDL). Spasticity was evaluated using the modified Ashworth Scale (MAS) at the two time points. QoL evaluated with the CPCHILD questionnaire and the KINDL improved from pre - implantation to follow-up. MAS markedly decreased from 3.8 to 1.7. All interviewed participants indicated that their expectations had been met and that they would choose ITB treatment again. Intrathecal treatment of baclofen is an excellent method for spasticity management in children with severe cerebral palsy. Quality of life sustainably improves, parents' satisfaction is high and the level of spasticity decreases. Therefore, baclofen treatment can be highly recommended in non-ambulant children with CP suffering from spasticity. Copyright © 2017 European Paediatric Neurology Society. Published by Elsevier Ltd. All rights reserved.
Edge-directed inference for microaneurysms detection in digital fundus images
NASA Astrophysics Data System (ADS)
Huang, Ke; Yan, Michelle; Aviyente, Selin
2007-03-01
Microaneurysms (MAs) detection is a critical step in diabetic retinopathy screening, since MAs are the earliest visible warning of potential future problems. A variety of algorithms have been proposed for MAs detection in mass screening. Different methods have been proposed for MAs detection. The core technology for most of existing methods is based on a directional mathematical morphological operation called "Top-Hat" filter that requires multiple filtering operations at each pixel. Background structure, uneven illumination and noise often cause confusion between MAs and some non-MA structures and limits the applicability of the filter. In this paper, a novel detection framework based on edge directed inference is proposed for MAs detection. The candidate MA regions are first delineated from the edge map of a fundus image. Features measuring shape, brightness and contrast are extracted for each candidate MA region to better exclude false detection from true MAs. Algorithmic analysis and empirical evaluation reveal that the proposed edge directed inference outperforms the "Top-Hat" based algorithm in both detection accuracy and computational speed.
Dossi, Andrea; Lecci, Francesca; Longo, Francesco; Morelli, Marco
2017-02-01
Many healthcare scholars have applied institutional theories to the study of management accounting systems (MAS) change. However, little attention has been devoted to MAS change within groups. Kostova et al. highlight the limitations of traditional institutional frameworks in studying groups since they are characterised not only by the existence of external institutional environments but also by intra-organisational (meso-level) ones. Given this background, the research question is: how does the meso-level institutional environment affect MAS change in healthcare groups? We use a longitudinal multiple-case study design to understand the role of headquarters in shaping local MAS change. We would expect companies to adopt similar MAS. However, we argue that the relationship between external institutions and MAS change cannot be wholly understood without taking into consideration the role of headquarters. Our analysis shows how hospitals facing the same external institutional environment implement different MAS as a consequence of different parenting styles. From a scientific perspective, our article contributes to broaden traditional institutional theoretical frameworks.
Gravity Probe B: final results of a space experiment to test general relativity.
Everitt, C W F; DeBra, D B; Parkinson, B W; Turneaure, J P; Conklin, J W; Heifetz, M I; Keiser, G M; Silbergleit, A S; Holmes, T; Kolodziejczak, J; Al-Meshari, M; Mester, J C; Muhlfelder, B; Solomonik, V G; Stahl, K; Worden, P W; Bencze, W; Buchman, S; Clarke, B; Al-Jadaan, A; Al-Jibreen, H; Li, J; Lipa, J A; Lockhart, J M; Al-Suwaidan, B; Taber, M; Wang, S
2011-06-03
Gravity Probe B, launched 20 April 2004, is a space experiment testing two fundamental predictions of Einstein's theory of general relativity (GR), the geodetic and frame-dragging effects, by means of cryogenic gyroscopes in Earth orbit. Data collection started 28 August 2004 and ended 14 August 2005. Analysis of the data from all four gyroscopes results in a geodetic drift rate of -6601.8±18.3 mas/yr and a frame-dragging drift rate of -37.2±7.2 mas/yr, to be compared with the GR predictions of -6606.1 mas/yr and -39.2 mas/yr, respectively ("mas" is milliarcsecond; 1 mas=4.848×10(-9) rad).
NASA Technical Reports Server (NTRS)
Arnold, G. Thomas; Fitzgerald, Michael; Grant, Patrick S.; King, Michael D.
1994-01-01
Calibration of the visible and near-infrared (near-IR) channels of the MODIS Airborne Simulator (MAS) is derived from observations of a calibrated light source. For the 1992 Atlantic Stratocumulus Transition Experiment (ASTEX) field deployment, the calibrated light source was the NASA Goddard 48-inch integrating hemisphere. Tests during the ASTEX deployment were conducted to calibrate the hemisphere and then the MAS. This report summarizes the ASTEX hemisphere calibration, and then describes how the MAS was calibrated from the hemisphere data. All MAS calibration measurements are presented and determination of the MAS calibration coefficients (raw counts to radiance conversion) is discussed. In addition, comparisons to an independent MAS calibration by Ames personnel using their 30-inch integrating sphere is discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Popa, Karin; Raison, Philippe E., E-mail: philippe.raison@ec.europa.eu; Martel, Laura
2015-10-15
PuPO{sub 4} was prepared by a solid state reaction method and its crystal structure at room temperature was solved by powder X-ray diffraction combined with Rietveld refinement. High resolution XANES measurements confirm the +III valence state of plutonium, in agreement with valence bond derivation. The presence of the americium (as β{sup −} decay product of plutonium) in the +III oxidation state was determined based on XANES spectroscopy. High resolution solid state {sup 31}P NMR agrees with the XANES results and the presence of a solid-solution. - Graphical abstract: A full structural analysis of PuPO{sub 4} based on Rietveld analysis ofmore » room temperature X-ray diffraction data, XANES and MAS NMR measurements was performed. - Highlights: • The crystal structure of PuPO{sub 4} monazite is solved. • In PuPO{sub 4} plutonium is strictly trivalent. • The presence of a minute amount of Am{sup III} is highlighted. • We propose PuPO{sub 4} as a potential reference material for spectroscopic and microscopic studies.« less
VizieR Online Data Catalog: OGLE high proper motion stars towards MC (Soszynski+, 2002)
NASA Astrophysics Data System (ADS)
Soszynski, I.; Zebrun, K.; Udalski, A.; Wozniak, P. R.; Szymanski, M.; Kubiak, M.; Pietrzynski, G.; Szewczyk, O.; Wyrzykowski, L.
2002-11-01
We present a catalog of high proper motion (HPM) stars detected in the foreground of central parts of the Magellanic Clouds. The Catalog contains 2161 objects in the 4.5 square degree area towards the LMC, and 892 HPM stars in the 2.4 square degree area towards the SMC. The Catalog is based on observations collected during four years of the OGLE-II microlensing survey. The Difference Image Analysis (DIA) of the images provided candidate HPM stars with proper motion as small as 4mas/yr. These appeared as pseudo-variables, and were all measured astrometrically on all CCD images, providing typically about 400 data points per star. The reference frame was defined by the majority of background stars, most of them members of the Magellanic Clouds. The reflex motion due to solar velocity with respect to the local standards of rest is clearly seen. The largest proper motion in our sample is 363mas/yr. Parallaxes were measured with errors smaller than 20% for several stars. (2 data files).
2012-01-01
Executive Summary In July 2010, the Medical Advisory Secretariat (MAS) began work on a Chronic Obstructive Pulmonary Disease (COPD) evidentiary framework, an evidence-based review of the literature surrounding treatment strategies for patients with COPD. This project emerged from a request by the Health System Strategy Division of the Ministry of Health and Long-Term Care that MAS provide them with an evidentiary platform on the effectiveness and cost-effectiveness of COPD interventions. After an initial review of health technology assessments and systematic reviews of COPD literature, and consultation with experts, MAS identified the following topics for analysis: vaccinations (influenza and pneumococcal), smoking cessation, multidisciplinary care, pulmonary rehabilitation, long-term oxygen therapy, noninvasive positive pressure ventilation for acute and chronic respiratory failure, hospital-at-home for acute exacerbations of COPD, and telehealth (including telemonitoring and telephone support). Evidence-based analyses were prepared for each of these topics. For each technology, an economic analysis was also completed where appropriate. In addition, a review of the qualitative literature on patient, caregiver, and provider perspectives on living and dying with COPD was conducted, as were reviews of the qualitative literature on each of the technologies included in these analyses. The Chronic Obstructive Pulmonary Disease Mega-Analysis series is made up of the following reports, which can be publicly accessed at the MAS website at: http://www.hqontario.ca/en/mas/mas_ohtas_mn.html. Chronic Obstructive Pulmonary Disease (COPD) Evidentiary Framework Influenza and Pneumococcal Vaccinations for Patients With Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Smoking Cessation for Patients With Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Community-Based Multidisciplinary Care for Patients With Stable Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Pulmonary Rehabilitation for Patients With Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Long-term Oxygen Therapy for Patients With Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Noninvasive Positive Pressure Ventilation for Acute Respiratory Failure Patients With Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Noninvasive Positive Pressure Ventilation for Chronic Respiratory Failure Patients With Stable Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Hospital-at-Home Programs for Patients With Acute Exacerbations of Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Home Telehealth for Patients With Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Cost-Effectiveness of Interventions for Chronic Obstructive Pulmonary Disease Using an Ontario Policy Model Experiences of Living and Dying With COPD: A Systematic Review and Synthesis of the Qualitative Empirical Literature For more information on the qualitative review, please contact Mita Giacomini at: http://fhs.mcmaster.ca/ceb/faculty_member_giacomini.htm. For more information on the economic analysis, please visit the PATH website: http://www.path-hta.ca/About-Us/Contact-Us.aspx. The Toronto Health Economics and Technology Assessment (THETA) collaborative has produced an associated report on patient preference for mechanical ventilation. For more information, please visit the THETA website: http://theta.utoronto.ca/static/contact. Objective The objective of this health technology assessment was to determine the effectiveness and cost-effectiveness of noninvasive ventilation for stable chronic obstructive pulmonary disease (COPD). Clinical Need: Condition and Target Population Noninvasive ventilation is used for COPD patients with chronic respiratory failure. Chronic respiratory failure in COPD patients may be due to the inability of the pulmonary system to coordinate ventilation, leading to adverse arterial levels of oxygen and carbon dioxide. Noninvasive ventilation in stable COPD patients has the potential to improve quality of life, prolong survival, and improve gas exchange and sleep quality in patients who are symptomatic after optimal therapy, have hypercapnia or nocturnal hypoventilation and mild hypercapnia, and are frequently hospitalized. Technology Noninvasive positive pressure ventilation (NPPV) is any form of positive ventilatory support without the use of an endotracheal tube. For stable COPD, the standard of care when using noninvasive ventilation is bilevel positive airway pressure (BiPAP). Bilevel positive airway pressure involves both inspiratory and expiratory pressure, high during inspiration and lower during expiration. It acts as a pressure support to accentuate a patient’s inspiratory efforts. The gradient between pressures maintains alveolar ventilation and helps to reduce carbon dioxide levels. Outpatients typically use BiPAP at night. Additional advantages of using BiPAP include resting of respiratory muscles, decreased work of breathing, and control of obstructive hypopnea. Research Question What is the effectiveness and cost-effectiveness of noninvasive ventilation, compared with no ventilation while receiving usual care, for stable COPD patients? Research Methods Literature Search Search Strategy A literature search was performed on December 3, 2010, using OVID MEDLINE, OVID MEDLINE In-Process and Other Non-Indexed Citations, OVID EMBASE, EBSCO Cumulative Index to Nursing & Allied Health Literature (CINAHL), the Wiley Cochrane Library, and the Centre for Reviews and Dissemination database for studies published from January 1, 2004 to December 3, 2010. Abstracts were reviewed by a single reviewer and, for those studies meeting the eligibility criteria, full-text articles were obtained. Reference lists were also examined for any additional relevant studies not identified through the search. When the reviewer was unsure of the eligibility of articles, a second clinical epidemiologist and then a group of epidemiologists reviewed these until consensus was reached. Inclusion Criteria full-text English language articles, studies published between January 1, 2004 and December 3, 2010, journal articles that report on the effectiveness or cost-effectiveness of noninvasive ventilation, clearly described study design and methods, and health technology assessments, systematic reviews, meta-analyses, randomized controlled trials (RCTs). Exclusion Criteria non-English papers animal or in vitro studies case reports, case series, or case-case studies cross-over RCTs studies on noninvasive negative pressure ventilation (e.g., iron lung) studies that combine ventilation therapy with other regimens (e.g., daytime NPPV plus exercise or pulmonary rehabilitation) studies on heliox with NPPV studies on pulmonary rehabilitation with NPPV Outcomes of Interest mortality/survival hospitalizations/readmissions length of stay in hospital forced expiratory volume arterial partial pressure of oxygen arterial partial pressure of carbon dioxide dyspnea exercise tolerance health-related quality of life Note: arterial pressure of oxygen and carbon dioxide are surrogate outcomes. Statistical Methods A meta-analysis and an analysis of individual studies were performed using Review Manager Version 5. For continuous data, a mean difference was calculated, and for dichotomous data, a relative risk ratio was calculated for RCTs. For continuous variables with mean baseline and mean follow-up data, a change value was calculated as the difference between the 2 mean values. Quality of Evidence The quality of each included study was assessed taking into consideration allocation concealment, randomization, blinding, power/sample size, withdrawals/dropouts, and intention-to-treat analyses. The quality of the body of evidence was assessed as high, moderate, low, or very low according to the GRADE Working Group criteria. The following definitions of quality were used in grading the quality of the evidence: High Further research is very unlikely to change confidence in the estimate of effect. Moderate Further research is likely to have an important impact on confidence in the estimate of effect and may change the estimate. Low Further research is very likely to have an important impact on confidence in the estimate of effect and is likely to change the estimate. Very Low Any estimate of effect is very uncertain Summary of Findings Conclusions The following conclusions refer to stable, severe COPD patients receiving usual care. Short-Term Studies Based on low quality of evidence, there is a beneficial effect of NPPV compared with no ventilation on oxygen gas exchange, carbon dioxide gas exchange, and exercise tolerance measured using the 6 Minute Walking Test. Based on very low quality of evidence, there is no effect of NPPV therapy on lung function measured as forced expiratory volume in 1 second (Type II error not excluded). Long-Term Studies Based on moderate quality of evidence, there is no effect of NPPV therapy for the outcomes of mortality, lung function measured as forced expiratory volume in 1 second, and exercise tolerance measured using the 6 Minute Walking Test. Based on low quality of evidence, there is no effect of NPPV therapy for the outcomes of oxygen gas exchange and carbon dioxide gas exchange (Type II error not excluded). Qualitative Assessment Based on low quality of evidence, there is a beneficial effect of NPPV compared with no ventilation for dyspnea based on reduced Borg score or Medical Research Council dyspnea score. Based on moderate quality of evidence, there is no effect of NPPV therapy for hospitalizations. Health-related quality of life could not be evaluated. PMID:23074437
Palotie, Tuula; Riekki, Siru; Mäkitie, Antti; Bachour, Adel; Arte, Sirpa; Bäck, Leif
2017-10-01
Our aim was to evaluate the effect of mandible advancement splint (MAS) in mild, moderate, and severe obstructive sleep apnea (OSA). We also determined, if and in which OSA-groups the adequate forward movement in MAS could be quantified without sleep registration for different OSA levels. A retrospective study. The effect of MAS was measured with clinical methods and by sleep registration. The series consisted of 103 patients, 75 males and 28 females (mean age 52 years) suffering from mild (32 per cent), moderate (32 per cent), or severe (36 per cent) OSA, who were treated with MAS at Helsinki University Hospital, Finland during the years 2011-2012. Seventy per cent of the patients had tried continuous positive airway pressure (CPAP) before MAS. The lower the body mass index (BMI) was the bigger the probability was to get apnea/hypopnea index (AHI) values <5 per hour with MAS (P < 0.01). The total AHI decreased significantly from the baseline with MAS: 23 per hour (range 5-89) to 6 per hour (range 0.3-54), (P < 0.001). The mean oxygen desaturation index (ODI4%) improved significantly from 16 per hour (range 1-76) to 5.3 per hour (range 0.2-49), (P < 0.01), and the minimum oxygen saturation improved significantly from 84 per cent (67-91) to 87 per cent (68-93), (P < 0.01). The reduction of AHI with MAS was significantly bigger in patients with a previous CPAP experience (73 per cent) than those who did not tried CPAP therapy. The positive correlation was found between the decrease in AHI and the increase of the protrusion in MAS. Both sleep recordings and subjective indicators demonstrated that MAS therapy was successful in OSA based on ESS, total AHI, ODI4%, and minimum oxygen saturation values. It seems useful to increase the protrusion at its maximal clinical tolerance. An experienced dentist could make therapeutically decision concerning the follow up of MAS efficacy regardless of the result of sleep study. We suggest that MAS is a valuable treatment alternative for CPAP. However, the previous use of CPAP with MAS as well as lower baseline BMI seem to have a positive correlation with the success of MAS therapy. © The Author 2016. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com
Maternal syphilis and accomplishing sexual partner treatment: still a huge gap.
Dallé, Jessica; Baumgarten, Vanessa Z; Ramos, Mauro C; Jimenez, Mirela F; Acosta, Lisiane; Bumaguin, Daniela B; Antonello, Vicente S
2017-08-01
Congenital syphilis (CS) is a preventable epidemic disease for which control is hindered by socioeconomic and health system issues. Inadequately treated maternal syphilis (MaS) commonly has serious adverse obstetric outcomes. This study - which is a cross-sectional study in a Brazilian large urban public Mother and Child hospital, making use of secondary data - evaluated the occurrence of treatment of sexual partners (SP) among women with MaS. The results showed that 771 MaS cases were identified from 2007 to 2014. No information on SP treatment was available in 570 (73.9%) cases. Of the 201 cases presenting information, 25 (12.4%) SP were treated. Out of 164 women having six or more prenatal visits, 25 (15.2%) SP received treatment. Data analyzed biennially have shown a growing trend of cases without collected information, ranging from 27.2% in 2007-2008 to 87.5% in 2013-2014. No linear trend in proportions of treated SP (maximum 7.4% SP treated) was found. Thus, in this study, it has been concluded that the proportion of SP adequately treated was consistently low, and the quality of information deteriorated during the studied period. Prenatal care per se, as provided, was not effective in delivering adequate treatment of SP. Creative integrated services with SP active participation are greatly needed if CS is to be controlled.
Kwan, Bethany M; Sills, Marion R; Graham, Deborah; Hamer, Mika K; Fairclough, Diane L; Hammermeister, K E; Kaiser, Alicyn; de Jesus Diaz-Perez, Maria; Schilling, Lisa M
2016-01-01
Patient-reported outcome (PRO) measures offer value for clinicians and researchers, although priorities and value propositions can conflict. PRO implementation in clinical practice may benefit from stakeholder engagement methods to align research and clinical practice stakeholder perspectives. The objective is to demonstrate the use of stakeholder engagement in PRO implementation. Engaged stakeholders represented researchers and clinical practice representatives from the SAFTINet practice-based research network (PBRN). A stakeholder engagement process involving iterative analysis, deliberation, and decision making guided implementation of a medication adherence PRO measure (the Medication Adherence Survey [MAS]) for patients with hypertension and/or hyperlipidemia. Over 9 months, 40 of 45 practices (89%) implemented the MAS, collecting 3,247 surveys (mean = 72, median = 30, range: 0 - 416). Facilitators included: an electronic health record (EHR) with readily modifiable templates; existing staff, tools and workflows in which the MAS could be integrated (e.g., health risk appraisals, hypertension-specific visits, care coordinators); and engaged leadership and quality improvement teams. Stakeholder engagement appeared useful for promoting PRO measure implementation in clinical practice, in a way that met the needs of both researchers and clinical practice stakeholders. Limitations of this approach and opportunities for improving the PRO data collection infrastructure in PBRNs are discussed. © Copyright 2016 by the American Board of Family Medicine.
Martel, L; Somers, J; Berkmann, C; Koepp, F; Rothermel, A; Pauvert, O; Selfslag, C; Farnan, I
2013-05-01
A concept to integrate a commercial high-resolution, magic angle spinning nuclear magnetic resonance (MAS-NMR) probe capable of very rapid rotation rates (70 kHz) in a hermetically sealed enclosure for the study of highly radiotoxic materials has been developed and successfully demonstrated. The concept centres on a conventional wide bore (89 mm) solid-state NMR magnet operating with industry standard 54 mm diameter probes designed for narrow bore magnets. Rotor insertion and probe tuning take place within a hermetically enclosed glovebox, which extends into the bore of the magnet, in the space between the probe and the magnet shim system. Oxygen-17 MAS-NMR measurements demonstrate the possibility of obtaining high quality spectra from small sample masses (~10 mg) of highly radiotoxic material and the need for high spinning speeds to improve the spectral resolution when working with actinides. The large paramagnetic susceptibility arising from actinide paramagnetism in (Th(1-x)U(x))O2 solid solutions gives rise to extensive spinning sidebands and poor resolution at 15 kHz, which is dramatically improved at 55 kHz. The first (17)O MAS-NMR measurements on NpO(2+x) samples spinning at 55 kHz are also reported. The glovebox approach developed here for radiotoxic materials can be easily adapted to work with other hazardous or even air sensitive materials.
Low-dose CT for quantitative analysis in acute respiratory distress syndrome
2013-01-01
Introduction The clinical use of serial quantitative computed tomography (CT) to characterize lung disease and guide the optimization of mechanical ventilation in patients with acute respiratory distress syndrome (ARDS) is limited by the risk of cumulative radiation exposure and by the difficulties and risks related to transferring patients to the CT room. We evaluated the effects of tube current-time product (mAs) variations on quantitative results in healthy lungs and in experimental ARDS in order to support the use of low-dose CT for quantitative analysis. Methods In 14 sheep chest CT was performed at baseline and after the induction of ARDS via intravenous oleic acid injection. For each CT session, two consecutive scans were obtained applying two different mAs: 60 mAs was paired with 140, 15 or 7.5 mAs. All other CT parameters were kept unaltered (tube voltage 120 kVp, collimation 32 × 0.5 mm, pitch 0.85, matrix 512 × 512, pixel size 0.625 × 0.625 mm). Quantitative results obtained at different mAs were compared via Bland-Altman analysis. Results Good agreement was observed between 60 mAs and 140 mAs and between 60 mAs and 15 mAs (all biases less than 1%). A further reduction of mAs to 7.5 mAs caused an increase in the bias of poorly aerated and nonaerated tissue (-2.9% and 2.4%, respectively) and determined a significant widening of the limits of agreement for the same compartments (-10.5% to 4.8% for poorly aerated tissue and -5.9% to 10.8% for nonaerated tissue). Estimated mean effective dose at 140, 60, 15 and 7.5 mAs corresponded to 17.8, 7.4, 2.0 and 0.9 mSv, respectively. Image noise of scans performed at 140, 60, 15 and 7.5 mAs corresponded to 10, 16, 38 and 74 Hounsfield units, respectively. Conclusions A reduction of effective dose up to 70% has been achieved with minimal effects on lung quantitative results. Low-dose computed tomography provides accurate quantitative results and could be used to characterize lung compartment distribution and possibly monitor time-course of ARDS with a lower risk of exposure to ionizing radiation. A further radiation dose reduction is associated with lower accuracy in quantitative results. PMID:24004842
Zhang, Hua; Huang, Jing; Ma, Jianhua; Bian, Zhaoying; Feng, Qianjin; Lu, Hongbing; Liang, Zhengrong; Chen, Wufan
2014-09-01
Repeated X-ray computed tomography (CT) scans are often required in several specific applications such as perfusion imaging, image-guided biopsy needle, image-guided intervention, and radiotherapy with noticeable benefits. However, the associated cumulative radiation dose significantly increases as comparison with that used in the conventional CT scan, which has raised major concerns in patients. In this study, to realize radiation dose reduction by reducing the X-ray tube current and exposure time (mAs) in repeated CT scans, we propose a prior-image induced nonlocal (PINL) regularization for statistical iterative reconstruction via the penalized weighted least-squares (PWLS) criteria, which we refer to as "PWLS-PINL". Specifically, the PINL regularization utilizes the redundant information in the prior image and the weighted least-squares term considers a data-dependent variance estimation, aiming to improve current low-dose image quality. Subsequently, a modified iterative successive overrelaxation algorithm is adopted to optimize the associative objective function. Experimental results on both phantom and patient data show that the present PWLS-PINL method can achieve promising gains over the other existing methods in terms of the noise reduction, low-contrast object detection, and edge detail preservation.
Ma, Jianhua; Bian, Zhaoying; Feng, Qianjin; Lu, Hongbing; Liang, Zhengrong; Chen, Wufan
2014-01-01
Repeated x-ray computed tomography (CT) scans are often required in several specific applications such as perfusion imaging, image-guided biopsy needle, image-guided intervention, and radiotherapy with noticeable benefits. However, the associated cumulative radiation dose significantly increases as comparison with that used in the conventional CT scan, which has raised major concerns in patients. In this study, to realize radiation dose reduction by reducing the x-ray tube current and exposure time (mAs) in repeated CT scans, we propose a prior-image induced nonlocal (PINL) regularization for statistical iterative reconstruction via the penalized weighted least-squares (PWLS) criteria, which we refer to as “PWLS-PINL”. Specifically, the PINL regularization utilizes the redundant information in the prior image and the weighted least-squares term considers a data-dependent variance estimation, aiming to improve current low-dose image quality. Subsequently, a modified iterative successive over-relaxation algorithm is adopted to optimize the associative objective function. Experimental results on both phantom and patient data show that the present PWLS-PINL method can achieve promising gains over the other existing methods in terms of the noise reduction, low-contrast object detection and edge detail preservation. PMID:24235272
Yu, Jiwen; Zhang, Ke; Li, Shuaiyang; Yu, Shuxun; Zhai, Honghong; Wu, Man; Li, Xingli; Fan, Shuli; Song, Meizhen; Yang, Daigang; Li, Yunhai; Zhang, Jinfa
2013-01-01
Identification of stable quantitative trait loci (QTLs) across different environments and mapping populations is a prerequisite for marker-assisted selection (MAS) for cotton yield and fiber quality. To construct a genetic linkage map and to identify QTLs for fiber quality and yield traits, a backcross inbred line (BIL) population of 146 lines was developed from a cross between Upland cotton (Gossypium hirsutum) and Egyptian cotton (Gossypium barbadense) through two generations of backcrossing using Upland cotton as the recurrent parent followed by four generations of self pollination. The BIL population together with its two parents was tested in five environments representing three major cotton production regions in China. The genetic map spanned a total genetic distance of 2,895 cM and contained 392 polymorphic SSR loci with an average genetic distance of 7.4 cM per marker. A total of 67 QTLs including 28 for fiber quality and 39 for yield and its components were detected on 23 chromosomes, each of which explained 6.65-25.27% of the phenotypic variation. Twenty-nine QTLs were located on the At subgenome originated from a cultivated diploid cotton, while 38 were on the Dt subgenome from an ancestor that does not produce spinnable fibers. Of the eight common QTLs (12%) detected in more than two environments, two were for fiber quality traits including one for fiber strength and one for uniformity, and six for yield and its components including three for lint yield, one for seedcotton yield, one for lint percentage and one for boll weight. QTL clusters for the same traits or different traits were also identified. This research represents one of the first reports using a permanent advanced backcross inbred population of an interspecific hybrid population to identify QTLs for fiber quality and yield traits in cotton across diverse environments. It provides useful information for transferring desirable genes from G. barbadense to G. hirsutum using MAS.
Ravelli, Angelo; Minoia, Francesca; Davì, Sergio; Horne, AnnaCarin; Bovis, Francesca; Pistorio, Angela; Aricò, Maurizio; Avcin, Tadej; Behrens, Edward M; De Benedetti, Fabrizio; Filipovic, Lisa; Grom, Alexei A; Henter, Jan-Inge; Ilowite, Norman T; Jordan, Michael B; Khubchandani, Raju; Kitoh, Toshiyuki; Lehmberg, Kai; Lovell, Daniel J; Miettunen, Paivi; Nichols, Kim E; Ozen, Seza; Pachlopnik Schmid, Jana; Ramanan, Athimalaipet V; Russo, Ricardo; Schneider, Rayfel; Sterba, Gary; Uziel, Yosef; Wallace, Carol; Wouters, Carine; Wulffraat, Nico; Demirkaya, Erkan; Brunner, Hermine I; Martini, Alberto; Ruperto, Nicolino; Cron, Randy Q
2016-03-01
To develop criteria for the classification of macrophage activation syndrome (MAS) in patients with systemic juvenile idiopathic arthritis (JIA). A multistep process, based on a combination of expert consensus and analysis of real patient data, was conducted. A panel of 28 experts was first asked to classify 428 patient profiles as having or not having MAS, based on clinical and laboratory features at the time of disease onset. The 428 profiles comprised 161 patients with systemic JIA-associated MAS and 267 patients with a condition that could potentially be confused with MAS (active systemic JIA without evidence of MAS, or systemic infection). Next, the ability of candidate criteria to classify individual patients as having MAS or not having MAS was assessed by evaluating the agreement between the classification yielded using the criteria and the consensus classification of the experts. The final criteria were selected in a consensus conference. Experts achieved consensus on the classification of 391 of the 428 patient profiles (91.4%). A total of 982 candidate criteria were tested statistically. The 37 best-performing criteria and 8 criteria obtained from the literature were evaluated at the consensus conference. During the conference, 82% consensus among experts was reached on the final MAS classification criteria. In validation analyses, these criteria had a sensitivity of 0.73 and a specificity of 0.99. Agreement between the classification (MAS or not MAS) obtained using the criteria and the original diagnosis made by the treating physician was high (κ=0.76). We have developed a set of classification criteria for MAS complicating systemic JIA and provided preliminary evidence of its validity. Use of these criteria will potentially improve understanding of MAS in systemic JIA and enhance efforts to discover effective therapies, by ensuring appropriate patient enrollment in studies. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Jearaphunt, Miti; Amparyup, Piti; Sangsuriya, Pakkakul; Charoensapsri, Walaiporn; Senapin, Saengchan; Tassanakajon, Anchalee
2015-01-01
Melanization mediated by the prophenoloxidase (proPO) activating system is a rapid immune response used by invertebrates against intruding pathogens. Several masquerade-like and serine proteinase homologues (SPHs) have been demonstrated to play an essential role in proPO activation in insects and crustaceans. In a previous study, we characterized the masquerade-like SPH, PmMasSPH1, in the black tiger shrimp Penaeus monodon as a multifunctional immune protein based on its recognition and antimicrobial activity against the Gram-negative bacteria Vibrio harveyi. In the present study, we identify a novel SPH, known as PmMasSPH2, composed of an N-terminal clip domain and a C-terminal SP-like domain that share high similarity to those of other insect and crustacean SPHs. We demonstrate that gene silencing of PmMasSPH1 and PmMasSPH2 significantly reduces PO activity, resulting in a high number of V. harveyi in the hemolymph. Interestingly, knockdown of PmMasSPH1 suppressed not only its gene transcript but also other immune-related genes in the proPO system (e.g., PmPPAE2) and antimicrobial peptides (e.g., PenmonPEN3, PenmonPEN5, crustinPm1 and Crus-likePm). The PmMasSPH1 and PmMasSPH2 also show binding activity to peptidoglycan (PGN) of Gram-positive bacteria. Using a yeast two-hybrid analysis and co-immunoprecipitation, we demonstrate that PmMasSPH1 specifically interacted with the final proteinase of the proPO cascade, PmPPAE2. Furthermore, the presence of both PmMasSPH1 and PmPPAE2 enhances PGN-induced PO activity in vitro. Taken together, these results suggest the importance of PmMasSPHs in the activation of the shrimp proPO system.
Wang, Lei; de Kloet, Annette D.; Pati, Dipanwita; Hiller, Helmut; Smith, Justin A.; Pioquinto, David J.; Ludin, Jacob A.; Oh, S. Paul; Katovich, Michael J.; Frazier, Charles J.; Raizada, Mohan K.; Krause, Eric G.
2016-01-01
Over-activation of brain renin-angiotensin system (RAS) has been implicated in the etiology of anxiety disorders. Angiotensin converting enzyme (ACE2) inhibits RAS activity by converting angiotensin II, the effector peptide of RAS, to angiotensin-(1-7), which activates Mas receptors (MasR). Whether increasing brain ACE2 activity reduces anxiety by stimulating central MasR is unknown. To test the hypothesis that increasing brain ACE2 activity reduces anxiety-like behavior via central MasR stimulation, we generated male mice overexpressing ACE2 (ACE2 KI mice) and wild type littermate controls (WT). ACE2 KI mice explored the open arms of the elevated plus maze (EPM) significantly more than WT, suggesting increasing ACE2 activity is anxiolytic. Central delivery of diminazene aceturate, an ACE2 activator, to C57BL/6 mice also reduced anxiety-like behavior in the EPM, but centrally administering ACE2 KI mice A-779, a MasR antagonist, abolished their anxiolytic phenotype, suggesting that ACE2 reduces anxiety-like behavior by activating central MasR. To identify the brain circuits mediating these effects, we measured Fos, a marker of neuronal activation, subsequent to EPM exposure and found that ACE2 KI mice had decreased Fos in the bed nucleus of stria terminalis but had increased Fos in the basolateral amygdala (BLA). Within the BLA, we determined that ~62% of GABAergic neurons contained MasR mRNA and expression of MasR mRNA was upregulated by ACE2 overexpression, suggesting that ACE2 may influence GABA neurotransmission within the BLA via MasR activation. Indeed, ACE2 overexpression was associated with increased frequency of spontaneous inhibitory postsynaptic currents (indicative of presynaptic release of GABA) onto BLA pyramidal neurons and central infusion of A-779 eliminated this effect. Collectively, these results suggest that ACE2 may reduce anxiety-like behavior by activating central MasR that facilitate GABA release onto pyramidal neurons within the BLA. PMID:26767952
Jearaphunt, Miti; Amparyup, Piti; Sangsuriya, Pakkakul; Charoensapsri, Walaiporn; Senapin, Saengchan; Tassanakajon, Anchalee
2015-01-01
Melanization mediated by the prophenoloxidase (proPO) activating system is a rapid immune response used by invertebrates against intruding pathogens. Several masquerade-like and serine proteinase homologues (SPHs) have been demonstrated to play an essential role in proPO activation in insects and crustaceans. In a previous study, we characterized the masquerade-like SPH, PmMasSPH1, in the black tiger shrimp Penaeus monodon as a multifunctional immune protein based on its recognition and antimicrobial activity against the Gram-negative bacteria Vibrio harveyi. In the present study, we identify a novel SPH, known as PmMasSPH2, composed of an N-terminal clip domain and a C-terminal SP-like domain that share high similarity to those of other insect and crustacean SPHs. We demonstrate that gene silencing of PmMasSPH1 and PmMasSPH2 significantly reduces PO activity, resulting in a high number of V. harveyi in the hemolymph. Interestingly, knockdown of PmMasSPH1 suppressed not only its gene transcript but also other immune-related genes in the proPO system (e.g., PmPPAE2) and antimicrobial peptides (e.g., PenmonPEN3, PenmonPEN5, crustinPm1 and Crus-likePm). The PmMasSPH1 and PmMasSPH2 also show binding activity to peptidoglycan (PGN) of Gram-positive bacteria. Using a yeast two-hybrid analysis and co-immunoprecipitation, we demonstrate that PmMasSPH1 specifically interacted with the final proteinase of the proPO cascade, PmPPAE2. Furthermore, the presence of both PmMasSPH1 and PmPPAE2 enhances PGN-induced PO activity in vitro. Taken together, these results suggest the importance of PmMasSPHs in the activation of the shrimp proPO system. PMID:25803442
Utz, Sandra; Huetteroth, Wolf; Vömel, Matthias; Schachtner, Joachim
2008-01-01
The paired antennal lobes (ALs) of the sphinx moth Manduca sexta serve as a well-established model for studying development of the primary integration centers for odor information in the brain. To further reveal the role of neuropeptides during AL development, we have analyzed cellular distribution, developmental time course, and regulation of the neuropeptide M. sexta allatotropin (Mas-AT). On the basis of morphology and appearance during AL formation, seven major types of Mas-AT-immunoreactive (ir) cells could be distinguished. Mas-AT-ir cells are identified as local, projection, and centrifugal neurons, which are either persisting larval or newly added adult-specific neurons. Complementary immunostaining with antisera against two other neuropeptide families (A-type allatostatins, RFamides) revealed colocalization within three of the Mas-AT-ir cell types. On the basis of this neurochemistry, the most prominent type of Mas-AT-ir neurons, the local AT neurons (LATn), could be divided in three subpopulations. The appearance of the Mas-AT-ir cell types occurring during metamorphosis parallels the rising titer of the developmental hormone 20-hydroxyecdysone (20E). Artificially shifting the 20E titer to an earlier developmental time point resulted in the precocious occurrence of Mas-AT immunostaining. This result supports the hypothesis that the pupal rise of 20E is causative for Mas-AT expression during AL development. Comparing localization and developmental time course of Mas-AT and other neuropeptides with the time course of AL formation suggests various functions for these neuropeptides during development, including an involvement in the formation of the olfactory glomeruli.
NASA Astrophysics Data System (ADS)
Rui, Xue; Cheng, Lishui; Long, Yong; Fu, Lin; Alessio, Adam M.; Asma, Evren; Kinahan, Paul E.; De Man, Bruno
2015-09-01
For PET/CT systems, PET image reconstruction requires corresponding CT images for anatomical localization and attenuation correction. In the case of PET respiratory gating, multiple gated CT scans can offer phase-matched attenuation and motion correction, at the expense of increased radiation dose. We aim to minimize the dose of the CT scan, while preserving adequate image quality for the purpose of PET attenuation correction by introducing sparse view CT data acquisition. We investigated sparse view CT acquisition protocols resulting in ultra-low dose CT scans designed for PET attenuation correction. We analyzed the tradeoffs between the number of views and the integrated tube current per view for a given dose using CT and PET simulations of a 3D NCAT phantom with lesions inserted into liver and lung. We simulated seven CT acquisition protocols with {984, 328, 123, 41, 24, 12, 8} views per rotation at a gantry speed of 0.35 s. One standard dose and four ultra-low dose levels, namely, 0.35 mAs, 0.175 mAs, 0.0875 mAs, and 0.043 75 mAs, were investigated. Both the analytical Feldkamp, Davis and Kress (FDK) algorithm and the Model Based Iterative Reconstruction (MBIR) algorithm were used for CT image reconstruction. We also evaluated the impact of sinogram interpolation to estimate the missing projection measurements due to sparse view data acquisition. For MBIR, we used a penalized weighted least squares (PWLS) cost function with an approximate total-variation (TV) regularizing penalty function. We compared a tube pulsing mode and a continuous exposure mode for sparse view data acquisition. Global PET ensemble root-mean-squares-error (RMSE) and local ensemble lesion activity error were used as quantitative evaluation metrics for PET image quality. With sparse view sampling, it is possible to greatly reduce the CT scan dose when it is primarily used for PET attenuation correction with little or no measureable effect on the PET image. For the four ultra-low dose levels simulated, sparse view protocols with 41 and 24 views best balanced the tradeoff between electronic noise and aliasing artifacts. In terms of lesion activity error and ensemble RMSE of the PET images, these two protocols, when combined with MBIR, are able to provide results that are comparable to the baseline full dose CT scan. View interpolation significantly improves the performance of FDK reconstruction but was not necessary for MBIR. With the more technically feasible continuous exposure data acquisition, the CT images show an increase in azimuthal blur compared to tube pulsing. However, this blurring generally does not have a measureable impact on PET reconstructed images. Our simulations demonstrated that ultra-low-dose CT-based attenuation correction can be achieved at dose levels on the order of 0.044 mAs with little impact on PET image quality. Highly sparse 41- or 24- view ultra-low dose CT scans are feasible for PET attenuation correction, providing the best tradeoff between electronic noise and view aliasing artifacts. The continuous exposure acquisition mode could potentially be implemented in current commercially available scanners, thus enabling sparse view data acquisition without requiring x-ray tubes capable of operating in a pulsing mode.
Rui, Xue; Cheng, Lishui; Long, Yong; Fu, Lin; Alessio, Adam M.; Asma, Evren; Kinahan, Paul E.; De Man, Bruno
2015-01-01
For PET/CT systems, PET image reconstruction requires corresponding CT images for anatomical localization and attenuation correction. In the case of PET respiratory gating, multiple gated CT scans can offer phase-matched attenuation and motion correction, at the expense of increased radiation dose. We aim to minimize the dose of the CT scan, while preserving adequate image quality for the purpose of PET attenuation correction by introducing sparse view CT data acquisition. Methods We investigated sparse view CT acquisition protocols resulting in ultra-low dose CT scans designed for PET attenuation correction. We analyzed the tradeoffs between the number of views and the integrated tube current per view for a given dose using CT and PET simulations of a 3D NCAT phantom with lesions inserted into liver and lung. We simulated seven CT acquisition protocols with {984, 328, 123, 41, 24, 12, 8} views per rotation at a gantry speed of 0.35 seconds. One standard dose and four ultra-low dose levels, namely, 0.35 mAs, 0.175 mAs, 0.0875 mAs, and 0.04375 mAs, were investigated. Both the analytical FDK algorithm and the Model Based Iterative Reconstruction (MBIR) algorithm were used for CT image reconstruction. We also evaluated the impact of sinogram interpolation to estimate the missing projection measurements due to sparse view data acquisition. For MBIR, we used a penalized weighted least squares (PWLS) cost function with an approximate total-variation (TV) regularizing penalty function. We compared a tube pulsing mode and a continuous exposure mode for sparse view data acquisition. Global PET ensemble root-mean-squares-error (RMSE) and local ensemble lesion activity error were used as quantitative evaluation metrics for PET image quality. Results With sparse view sampling, it is possible to greatly reduce the CT scan dose when it is primarily used for PET attenuation correction with little or no measureable effect on the PET image. For the four ultra-low dose levels simulated, sparse view protocols with 41 and 24 views best balanced the tradeoff between electronic noise and aliasing artifacts. In terms of lesion activity error and ensemble RMSE of the PET images, these two protocols, when combined with MBIR, are able to provide results that are comparable to the baseline full dose CT scan. View interpolation significantly improves the performance of FDK reconstruction but was not necessary for MBIR. With the more technically feasible continuous exposure data acquisition, the CT images show an increase in azimuthal blur compared to tube pulsing. However, this blurring generally does not have a measureable impact on PET reconstructed images. Conclusions Our simulations demonstrated that ultra-low-dose CT-based attenuation correction can be achieved at dose levels on the order of 0.044 mAs with little impact on PET image quality. Highly sparse 41- or 24- view ultra-low dose CT scans are feasible for PET attenuation correction, providing the best tradeoff between electronic noise and view aliasing artifacts. The continuous exposure acquisition mode could potentially be implemented in current commercially available scanners, thus enabling sparse view data acquisition without requiring x-ray tubes capable of operating in a pulsing mode. PMID:26352168
Park, Clara; Gruber-Rouh, Tatjana; Leithner, Doris; Zierden, Amelie; Albrecht, Mortiz H; Wichmann, Julian L; Bodelle, Boris; Elsabaie, Mohamed; Scholtz, Jan-Erik; Kaup, Moritz; Vogl, Thomas J; Beeres, Martin
2016-10-10
Evaluation of latest generation automated attenuation-based tube potential selection (ATPS) impact on image quality and radiation dose in contrast-enhanced chest-abdomen-pelvis computed tomography examinations for gynaecologic cancer staging. This IRB approved single-centre, observer-blinded retrospective study with a waiver for informed consent included a total of 100 patients with contrast-enhanced chest-abdomen-pelvis CT for gynaecologic cancer staging. All patients were examined with activated ATPS for adaption of tube voltage to body habitus. 50 patients were scanned on a third-generation dual-source CT (DSCT), and another 50 patients on a second-generation DSCT. Predefined image quality setting remained stable between both groups at 120 kV and a current of 210 Reference mAs. Subjective image quality assessment was performed by two blinded readers independently. Attenuation and image noise were measured in several anatomic structures. Signal-to-noise ratio (SNR) was calculated. For the evaluation of radiation exposure, CT dose index (CTDI vol ) values were compared. Diagnostic image quality was obtained in all patients. The median CTDI vol (6.1 mGy, range 3.9-22 mGy) was 40 % lower when using the algorithm compared with the previous ATCM protocol (median 10.2 mGy · cm, range 5.8-22.8 mGy). A reduction in potential to 90 kV occurred in 19 cases, a reduction to 100 kV in 23 patients and a reduction to 110 kV in 3 patients of our experimental cohort. These patients received significantly lower radiation exposure compared to the former used protocol. Latest generation automated ATPS on third-generation DSCT provides good diagnostic image quality in chest-abdomen-pelvis CT while average radiation dose is reduced by 40 % compared to former ATPS protocol on second-generation DSCT.
Poojary, Mahesha M; Passamonti, Paolo
2016-12-09
This paper reports on improved conventional thermal silylation (CTS) and microwave-assisted silylation (MAS) methods for simultaneous determination of tocopherols and sterols by gas chromatography. Reaction parameters in each of the methods developed were systematically optimized using a full factorial design followed by a central composite design. Initially, experimental conditions for CTS were optimized using a block heater. Further, a rapid MAS was developed and optimized. To understand microwave heating mechanisms, MAS was optimized by two distinct modes of microwave heating: temperature-controlled MAS and power-controlled MAS, using dedicated instruments where reaction temperature and microwave power level were controlled and monitored online. Developed methods: were compared with routine overnight derivatization. On a comprehensive level, while both CTS and MAS were found to be efficient derivatization techniques, MAS significantly reduced the reaction time. The optimal derivatization temperature and time for CTS found to be 55°C and 54min, while it was 87°C and 1.2min for temperature-controlled MAS. Further, a microwave power of 300W and a derivatization time 0.5min found to be optimal for power-controlled MAS. The use of an appropriate derivatization solvent, such as pyridine, was found to be critical for the successful determination. Catalysts, like potassium acetate and 4-dimethylaminopyridine, enhanced the efficiency slightly. The developed methods showed excellent analytical performance in terms of linearity, accuracy and precision. Copyright © 2016 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Kaya, Taciser; Goksel Karatepe, Altinay; Gunaydin, Rezzan; Koc, Aysegul; Altundal Ercan, Ulku
2011-01-01
The Modified Ashworth Scale (MAS) is commonly used in clinical practice for grading spasticity. However, it was modified recently by omitting grade "1+" of the MAS and redefining grade "2". The aim of this study was to investigate the inter-rater reliability of MAS and modified MAS (MMAS) for the assessment of poststroke elbow flexor spasticity.…
Chen, Ke; de Borne, François Dorlhac; Julio, Emilie; Obszynski, Julie; Pale, Patrick; Otten, Léon
2016-08-01
Previous studies have shown that Nicotiana tabacum contains three Agrobacterium-derived T-DNA sequences inherited from its paternal ancestor Nicotiana tomentosiformis. Among these, the TB locus carries an intact mannopine synthase 2' gene (TB-mas2'). This gene is similar to the Agrobacterium rhizogenes A4-mas2' gene that encodes the synthesis of the Amadori compound deoxyfructosyl-glutamine (DFG or santhopine). In this study we show that TB-mas2' is expressed at very low levels in N. tomentosiformis and in most N. tabacum cultivars; however, some cultivars show high TB-mas2' expression levels. The TB-mas2' promoter sequences of low- and high-expressing cultivars are identical. The low/high level of expression segregates as a single Mendelian factor in a cross between a low- and a high-expression cultivar. pTB-mas2'-GUS and pA4-mas2'-GUS reporter genes were stably introduced in N. benthamiana. Both were mainly expressed in the root expansion zone and leaf vasculature. Roots of tobacco cultivars with high TB-mas2' expression contain detectable levels of DFG. © 2016 The Authors The Plant Journal © 2016 John Wiley & Sons Ltd.
Sealed rotors for in situ high temperature high pressure MAS NMR
Hu, Jian Z.; Hu, Mary Y.; Zhao, Zhenchao; ...
2015-07-06
Magic angle spinning (MAS) nuclear magnetic resonance (NMR) investigations on heterogeneous samples containing solids, semi-solids, liquid and gases or a mixture of them under non-conventional conditions of a combined high pressure and high temperature, or cold temperature suffer from the unavailability of a perfectly sealed rotor. Here, we report the design of reusable and perfectly-sealed all-zircornia MAS rotors. The rotors are easy to use and are suitable for operation temperatures from below 0 to 250 °C and pressures up to 100 bar. As an example of potential applications we performed in situ MAS NMR investigations of AlPO₄-5 molecular sieve crystallization,more » a kinetic study of the cyclohexanol dehydration reaction using 13C MAS NMR, and an investigation of the metabolomics of intact biological tissue at low temperature using 1H HR-MAS NMR spectroscopy. The in situ MAS NMR experiments performed using the reported rotors allowed reproduction of the results from traditional batch reactions, while offering more detailed quantitative information at the molecular level, as demonstrated for the molecular sieve synthesis and activation energy measurements for cyclohexanol dehydration. The perfectly sealed rotor also shows promising application for metabolomics studies using 1H HR-MAS NMR.« less
Sealed rotors for in situ high temperature high pressure MAS NMR
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hu, Jian Z.; Hu, Mary Y.; Zhao, Zhenchao
Magic angle spinning (MAS) nuclear magnetic resonance (NMR) investigations on heterogeneous samples containing solids, semi-solids, liquid and gases or a mixture of them under non-conventional conditions of a combined high pressure and high temperature, or cold temperature suffer from the unavailability of a perfectly sealed rotor. Here, we report the design of reusable and perfectly-sealed all-zircornia MAS rotors. The rotors are easy to use and are suitable for operation temperatures from below 0 to 250 °C and pressures up to 100 bar. As an example of potential applications we performed in situ MAS NMR investigations of AlPO₄-5 molecular sieve crystallization,more » a kinetic study of the cyclohexanol dehydration reaction using 13C MAS NMR, and an investigation of the metabolomics of intact biological tissue at low temperature using 1H HR-MAS NMR spectroscopy. The in situ MAS NMR experiments performed using the reported rotors allowed reproduction of the results from traditional batch reactions, while offering more detailed quantitative information at the molecular level, as demonstrated for the molecular sieve synthesis and activation energy measurements for cyclohexanol dehydration. The perfectly sealed rotor also shows promising application for metabolomics studies using 1H HR-MAS NMR.« less
Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner.
Kakinuma, Ryutaro; Moriyama, Noriyuki; Muramatsu, Yukio; Gomi, Shiho; Suzuki, Masahiro; Nagasawa, Hirobumi; Kusumoto, Masahiko; Aso, Tomohiko; Muramatsu, Yoshihisa; Tsuchida, Takaaki; Tsuta, Koji; Maeshima, Akiko Miyagi; Tochigi, Naobumi; Watanabe, Shun-Ichi; Sugihara, Naoki; Tsukagoshi, Shinsuke; Saito, Yasuo; Kazama, Masahiro; Ashizawa, Kazuto; Awai, Kazuo; Honda, Osamu; Ishikawa, Hiroyuki; Koizumi, Naoya; Komoto, Daisuke; Moriya, Hiroshi; Oda, Seitaro; Oshiro, Yasuji; Yanagawa, Masahiro; Tomiyama, Noriyuki; Asamura, Hisao
2015-01-01
The image noise and image quality of a prototype ultra-high-resolution computed tomography (U-HRCT) scanner was evaluated and compared with those of conventional high-resolution CT (C-HRCT) scanners. This study was approved by the institutional review board. A U-HRCT scanner prototype with 0.25 mm x 4 rows and operating at 120 mAs was used. The C-HRCT images were obtained using a 0.5 mm x 16 or 0.5 mm x 64 detector-row CT scanner operating at 150 mAs. Images from both scanners were reconstructed at 0.1-mm intervals; the slice thickness was 0.25 mm for the U-HRCT scanner and 0.5 mm for the C-HRCT scanners. For both scanners, the display field of view was 80 mm. The image noise of each scanner was evaluated using a phantom. U-HRCT and C-HRCT images of 53 images selected from 37 lung nodules were then observed and graded using a 5-point score by 10 board-certified thoracic radiologists. The images were presented to the observers randomly and in a blinded manner. The image noise for U-HRCT (100.87 ± 0.51 Hounsfield units [HU]) was greater than that for C-HRCT (40.41 ± 0.52 HU; P < .0001). The image quality of U-HRCT was graded as superior to that of C-HRCT (P < .0001) for all of the following parameters that were examined: margins of subsolid and solid nodules, edges of solid components and pulmonary vessels in subsolid nodules, air bronchograms, pleural indentations, margins of pulmonary vessels, edges of bronchi, and interlobar fissures. Despite a larger image noise, the prototype U-HRCT scanner had a significantly better image quality than the C-HRCT scanners.
Mikat, Christian; Stenzel, Elena; Erfanian, Youssef; Wetter, Axel; Schlosser, Thomas; Forsting, Michael
2017-01-01
Objectives To evaluate the image quality and radiation dose of submillisievert standard-pitch CT pulmonary angiography (CTPA) with ultra-low dose contrast media administration in comparison to standard CTPA. Materials and methods Hundred patients (56 females, 44 males, mean age 69.6±15.4 years; median BMI: 26.6, IQR: 5.9) with suspected pulmonary embolism were examined with two different protocols (n = 50 each, group A: 80 kVp, ref. mAs 115, 25 ml of contrast medium; group B: 100 kVp, ref. mAs 150, 60 ml of contrast medium) using a dual-source CT equipped with automated exposure control. Objective and subjective image qualities, radiation exposure as well as the frequency of pulmonary embolism were evaluated. Results There was no significant difference in subjective image quality scores between two groups regarding pulmonary arteries (p = 0.776), whereby the interobserver agreement was excellent (group A: k = 0.9; group B k = 1.0). Objective image analysis revealed that signal intensities (SI), signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the pulmonary arteries were equal or significantly higher in group B. There was no significant difference in the frequency of pulmonary embolism (p = 0.65). Using the low dose and low contrast media protocol resulted in a radiation dose reduction by 71.8% (2.4 vs. 0.7 mSv; p<0.001). Conclusions This 80 kVp standard pitch CTPA protocol with 25 ml contrast agent volume can obtain sufficient image quality to exclude or diagnose pulmonary emboli while reducing radiation dose by approximately 71%. PMID:29045463
Hall, R L; Wood, E J; Kamberling, J P; Gerwig, G J; Vliegenthart, F G
1977-01-01
In addition to the already knownonosaccharides fucose, xylose, mannose, galactose, glucose, N-acetylgalactosamine and N-acetylglucosamine, the carbohydrate part of the haemocyanin from Helix pomatia (Roman snail) contains 3-O-methylgalactose, and that from Lymnaea stagnalis (a freshwater snail) 3-O-methylgalactose and 3-O-methylmannose. The 3-O-methyl sugars were identified by g.l.c.-mas spectrometry of the corresponding trimethylsilyl methyl glycosides and the alditol acetates, and by co-chromatography with the synthetic reference substances. PMID:889564
Applications of massively parallel computers in telemetry processing
NASA Technical Reports Server (NTRS)
El-Ghazawi, Tarek A.; Pritchard, Jim; Knoble, Gordon
1994-01-01
Telemetry processing refers to the reconstruction of full resolution raw instrumentation data with artifacts, of space and ground recording and transmission, removed. Being the first processing phase of satellite data, this process is also referred to as level-zero processing. This study is aimed at investigating the use of massively parallel computing technology in providing level-zero processing to spaceflights that adhere to the recommendations of the Consultative Committee on Space Data Systems (CCSDS). The workload characteristics, of level-zero processing, are used to identify processing requirements in high-performance computing systems. An example of level-zero functions on a SIMD MPP, such as the MasPar, is discussed. The requirements in this paper are based in part on the Earth Observing System (EOS) Data and Operation System (EDOS).
Wu, Yan; Jiang, Yaojun; Han, Xueli; Wang, Mingyue; Gao, Jianbo
2018-02-01
To investigate the repeatability and accuracy of quantitative CT (QCT) measurement of bone mineral density (BMD) by low-mAs using iterative model reconstruction (IMR) technique based on phantom model. European spine phantom (ESP) was selected and measured on the Philips Brilliance iCT Elite FHD machine for 10 times. Data were transmitted to the QCT PRO workstation to measure BMD (mg/cm 3 ) of the ESP (L1, L2, L3). Scanning method: the voltage of X-ray tube is 120 kV, the electric current of X-ray tube output in five respective groups A-E were: 20, 30, 40, 50 and 60 mAs. Reconstruction: all data were reconstructed using filtered back projection (FBP), IR levels of hybrid iterative reconstruction (iDose 4 , levels 1, 2, 3, 4, 5, 6 were used) and IMR (levels 1, 2, 3 were used). ROIs were placed in the middle of L1, L2 and L3 spine phantom in each group. CT values, noise and contrast-to-noise ratio (CNR) were measured and calculated. One-way analysis of variance (ANOVA) was used to compare BMD values of different mAs and different IMR. Radiation dose [volume CT dose index (CTDI vol ) and dose length product (DLP)] was positively correlated with tube current. In L1 with low BMD, different mAs in FBP showed P<0.05, indicating statistically significant BMD in ESP. In other iterative algorithms, different mAs under same iterative algorithms showed P>0.05, indicating no difference in BMD. And P>0.05 was observed among BMD of spine phantom in L1, L2 and L3 under same mAs joined with varied iterative reconstruction. The BMD in L1 varied greatly during FBP reconstruction, and less variation was observed in reconstruction of IMR [1] and IMR [2]. The BMD of L2 changed more during FBP reconstruction, where less was observed in IMR [2]. The BMD of L3 varied greatly during FBP reconstruction, and was less varied in all levels of iDose 4 and reconstruction of IMR [2]. In addition, along with continuous mAs incensement, the CNRs in various algorithms continued to increase. Among them, CNR with the FBP algorithm is the lowest, and CNR of the IMR [3] algorithm is the highest. Repeated measurements of BMD with QCT in the ESP multicenter showed that BMD changes in L1-L3 are the least varied at IMR [2] algorithm. It is recommended to scan at 120 kV with 20 mAs combined with IMR [2] algorithm. In this way, the BMD of spine by QCT could be accurately measured, while radiation dosage significantly reduced and imaging quality improved at the same time.
SU-E-I-95: Personalized Radiography Technical Parameters for Each Patient and Exam
DOE Office of Scientific and Technical Information (OSTI.GOV)
Soares, F; Camozzato, T; Kahl, G
Purpose: To determine exact electrical parameters (kV, mAs) a radiological technologist shall use taking account the exam and patient's structure, with guarantee of minimum dose and adequate quality image. Methods: A patient's absorbed dose equation was developed by means of Entrance Skin Dose (ESD), irradiated area and patient width for specific anatomy. ESD is calculated from a developed equation, where entrance surface air-KERMA and backscatter factor are included, with air-to-skin coefficient conversion. We developed specific Lambert-Beer attenuation equations derived from mass energy-absorption coefficients data for skin, fat, and muscle and bone as one tissue. Anatomy tissue thickness distribution at centralmore » X-ray location in anteroposterior incidence for hand and chest, was estimate by discounting constant skin and bone thickness from patient measured width, assuming the result as muscle and fat. A clinical research at a big hospital were executed when real parameters (kV, mAs, filtration, ripple) used by technologists were combined with the image quality and patient's data: anatomy width, height and weight. A correlation among the best images acquired and electrical parameters used were confronted with patient's data and dose estimation. The best combinations were used as gold standards. Results: For each anatomy, two equations were developed to calculate voltage (kV) and exposure (mAs) to reproduce and interpolate the gold standards. Patient is measured and data are input into equations, giving radiological technologists the right set of electrical parameters for that specific exam. Conclusion: This work indicates that radiological technologist can personalize the exact electrical parameters for each patient exam, instead of using standard values. It also guarantee that patients under or over-sized measures will receive the right dose for the best image. It will stop wrong empiric adjusts technologists do when examining a non-standard patient and reduce probability of radiography retaken because of over or under exposition.« less
Wang, Lucy; Crawford, John D; Reppermund, Simone; Trollor, Julian; Campbell, Lesley; Baune, Bernhard T; Sachdev, Perminder; Brodaty, Henry; Samaras, Katherine; Smith, Evelyn
2018-06-07
While obesity has been linked with lower quality of life in the general adult population, the prospective effects of present obesity on future quality of life amongst the elderly is unclear. This article investigates the cross-sectional and longitudinal relationships between obesity and aspects of quality of life in community-dwelling older Australians. A 2-year longitudinal sample of community dwellers aged 70-90 years at baseline, derived from the Sydney Memory and Ageing Study (MAS), was chosen for the study. Of the 1037 participants in the original MAS sample, a baseline (Wave 1) sample of 926 and a 2-year follow-up (Wave 2) sample of 751 subjects were retained for these analyses. Adiposity was measured using body mass index (BMI) and waist circumference (WC). Quality of life was measured using the Assessment of Quality of Life (6 dimensions) questionnaire (AQoL-6D) as well as the Satisfaction with Life Scale (SWLS). Linear regression and analysis of covariance (ANCOVA) were used to examine linear and non-linear relationships between BMI and WC and measures of health-related quality of life (HRQoL) and satisfaction with life, adjusting for age, sex, education, asthma, osteoporosis, depression, hearing and visual impairment, mild cognitive impairment, physical activity, and general health. Where a non-linear relationship was found, established BMI or WC categories were used in ANCOVA. Greater adiposity was associated with lower HRQoL but not life satisfaction. Regression modelling in cross-sectional analyses showed that higher BMI and greater WC were associated with lower scores for independent living, relationships, and pain (i.e. worse pain) on the AQoL-6D. In planned contrasts within a series of univariate analyses, obese participants scored lower in independent living and relationships, compared to normal weight and overweight participants. Longitudinal analyses found that higher baseline BMI and WC were associated with lower independent living scores at Wave 2. Obesity is associated with and predicts lower quality of life in elderly adults aged 70-90 years, and the areas most affected are independent living, social relationships, and the experience of pain.
Shin, Hee Jeong; Kim, Song Soo; Lee, Jae-Hwan; Park, Jae-Hyeong; Jeong, Jin-Ok; Jin, Seon Ah; Shin, Byung Seok; Shin, Kyung-Sook; Ahn, Moonsang
2016-06-01
To evaluate the feasibility of low-concentration contrast medium (CM) for vascular enhancement, image quality, and radiation dose on computed tomography aortography (CTA) using a combined low-tube-voltage and iterative reconstruction (IR) technique. Ninety subjects underwent dual-source CT (DSCT) operating in dual-source, high-pitch mode. DSCT scans were performed using both high-concentration CM (Group A, n = 50; Iomeprol 400) and low-concentration CM (Group B, n = 40; Iodixanol 270). Group A was scanned using a reference tube potential of 120 kVp and 120 reference mAs under automatic exposure control with IR. Group B was scanned using low-tube-voltage (80 or 100 kVp if body mass index ≥25 kg/m(2)) at a fixed current of 150 mAs, along with IR. Images of the two groups were compared regarding attenuation, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), iodine load, and radiation dose in various locations of the CTA. In comparison between Group A and Group B, the average mean attenuation (454.73 ± 86.66 vs. 515.96 ± 101.55 HU), SNR (25.28 ± 4.34 vs. 31.29 ± 4.58), and CNR (21.83 ± 4.20 vs. 27.55 ± 4.81) on CTA in Group B showed significantly greater values and significantly lower image noise values (18.76 ± 2.19 vs. 17.48 ± 3.34) than those in Group A (all Ps < 0.05). Homogeneous contrast enhancement from the ascending thoracic aorta to the infrarenal abdominal aorta was significantly superior in Group B (P < 0.05). Low-concentration CM and a low-tube-voltage combination technique using IR is a feasible method, showing sufficient contrast enhancement and image quality.
Management of Meconium-Stained Newborns in the Delivery Room.
Gandhi, Chintan Kiritkumar
2018-05-01
The approach to the management of meconium-stained newborns in the delivery room has been changing for over 40 years. The goal is to prevent meconium aspiration syndrome (MAS) and complications related to MAS. For decades, airway obstruction was believed to be a major component of MAS and, consequently, suction maneuvers to remove meconium from the airways were recommended to decrease the frequency and severity of MAS. Initial recommendations were based on observational studies. However, the incidence of MAS and mortality related to MAS has declined since the 1970s, mostly because of a decrease in the number of postterm deliveries. Recently updated guidelines by the American Heart Association and the Neonatal Resuscitation Program have reflected the strength of evidence supporting tracheal intubation and suctioning for nonvigorous, meconium-stained newborns. This article examines practice change since the 1970s in the delivery room management of meconium-stained newborns and evaluates evidence behind the changes.
Fast passage dynamic nuclear polarization on rotating solids
NASA Astrophysics Data System (ADS)
Mentink-Vigier, Frederic; Akbey, Ümit; Hovav, Yonatan; Vega, Shimon; Oschkinat, Hartmut; Feintuch, Akiva
2012-11-01
Magic Angle Spinning (MAS) Dynamic Nuclear Polarization (DNP) has proven to be a very powerful way to improve the signal to noise ratio of NMR experiments on solids. The experiments have in general been interpreted considering the Solid-Effect (SE) and Cross-Effect (CE) DNP mechanisms while ignoring the influence of sample spinning. In this paper, we show experimental data of MAS-DNP enhancements of 1H and 13C in proline and SH3 protein in glass forming water/glycerol solvent containing TOTAPOL. We also introduce a theoretical model that aims at explaining how the nuclear polarization is built in MAS-DNP experiments. By using Liouville space based simulations to include relaxation on two simple spin models, {electron-nucleus} and {electron-electron-nucleus}, we explain how the basic MAS-SE-DNP and MAS-CE-DNP processes work. The importance of fast energy passages and short level anti-crossing is emphasized and the differences between static DNP and MAS-DNP is explained. During a single rotor cycle the enhancement in the {electron-electron-nucleus} system arises from MAS-CE-DNP involving at least three kinds of two-level fast passages: an electron-electron dipolar anti-crossing, a single quantum electron MW encounter and an anti-crossing at the CE condition inducing nuclear polarization in- or decrements. Numerical, powder-averaged, simulations were performed in order to check the influence of the experimental parameters on the enhancement efficiencies. In particular we show that the spinning frequency dependence of the theoretical MAS-CE-DNP enhancement compares favorably with the experimental 1H and 13C MAS-DNP enhancements of proline and SH3.
Chicken parvovirus and its associations with malabsorption syndrome.
Finkler, F; Lima, D A; Cerva, C; Moraes, L B; Cibulski, S P; Teixeira, T F; Santos, H F; Almeida, L L; Roehe, P M; Franco, A C
2016-08-01
Malabsorption syndrome (MAS) is a multifactorial syndrome which is characterized by enteric disorders and reduced growth rates of broilers. Such condition is responsible for significant economic losses to the poultry industry. A possible association between chicken parvovirus (ChPV) infections and the occurrence of MAS has been proposed. However, such association has not to date been elucidated in view that ChPV has been detected in healthy as well as in MAS-affected chickens. This study aimed to detect and quantify ChPV loads in sera and tissues of MAS-affected, as well as in healthy broilers. Fifty nine, 39-day-old broilers (50 diseased, 9 healthy birds), obtained from the same flocks, were examined. The highest ChPV DNA loads were detected in MAS-affected broilers, particularly in fecal samples and intestinal tissues (~5500 genomic copies/300ng of total DNA). The average viral genome load in serum in MAS-affected birds was 1134copies/mL, whereas no viral DNA was found in sera and thymus tissues from healthy animals. These findings reveal that MAS-affected broilers consistently carry ChPV DNA is serum, whereas healthy animals do not. In addition, viral loads in tissues (bursa of Fabricius, spleen, intestine and liver) of MAS-affected birds were significantly higher in comparison to the same tissues from healthy broilers. Although preliminary, the results obtained here indicate an association between the detection of ChPV DNA in serum, in addition to high ChPV viral loads in tissues, and the occurrence of MAS in broilers. Further experiments should be performed to confirm such results. Copyright © 2016. Published by Elsevier Ltd.
Mansoori, A; Oryan, S; Nematbakhsh, M
2016-03-01
The vasodilatory effect of angiotensin 1-7 (Ang 1-7) is exerted in the vascular bed via Mas receptor (MasR) gender dependently. However, the crosstalk between MasR and angiotensin II (Ang II) types 1 and 2 receptors (AT1R and AT2R) may change some actions of Ang 1-7 in renal circulation. In this study by blocking AT1R and AT2R, the role of MasR in kidney hemodynamics was described. In anaesthetized male and female Wistar rats, the effects of saline as vehicle and MasR blockade (A779) were tested on mean arterial pressure (MAP), renal perfusion pressure (RPP), renal blood flow (RBF), and renal vascular resistance (RVR) when both AT1R and AT2R were blocked by losartan and PD123319, respectively. In male rats, when AT1R and AT2R were blocked, there was a tendency for the increase in RBF/wet kidney tissue weight (RBF/KW) to be elevated by A779 as compared with the vehicle (P=0.08), and this was not the case in female rats. The impact of MasR on renal hemodynamics appears not to be sexual dimorphism either when Ang II receptors were blocked. It seems that co-blockade of all AT1R, AT2R, and MasR may alter RBF/ KW in male more than in female rats. These findings support a crosstalk between MasR and Ang II receptors in renal circulation.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-21
... Ashby (410) 786-6322 Coverage Provisions. XI National Oncologic Positron Emission Stuart Caplan, RN, MAS... Tillman, RN, MAS (410) 786-9252 Facilities. XV Fluorodeoxyglucose Positron Emission Stuart Caplan, RN, MAS...
Jaudzems, Kristaps; Bertarello, Andrea; Chaudhari, Sachin R; Pica, Andrea; Cala-De Paepe, Diane; Barbet-Massin, Emeline; Pell, Andrew J; Akopjana, Inara; Kotelovica, Svetlana; Gajan, David; Ouari, Olivier; Tars, Kaspars; Pintacuda, Guido; Lesage, Anne
2018-06-18
Dynamic nuclear polarization (DNP) is a powerful way to overcome the sensitivity limitation of magic-angle-spinning (MAS) NMR experiments. However, the resolution of the DNP NMR spectra of proteins is compromised by severe line broadening associated with the necessity to perform experiments at cryogenic temperatures and in the presence of paramagnetic radicals. High-quality DNP-enhanced NMR spectra of the Acinetobacter phage 205 (AP205) nucleocapsid can be obtained by combining high magnetic field (800 MHz) and fast MAS (40 kHz). These conditions yield enhanced resolution and long coherence lifetimes allowing the acquisition of resolved 2D correlation spectra and of previously unfeasible scalar-based experiments. This enables the assignment of aromatic resonances of the AP205 coat protein and its packaged RNA, as well as the detection of long-range contacts, which are not observed at room temperature, opening new possibilities for structure determination. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Jaana, Mirou; Vartak, Smruti; Ward, Marcia M
2014-09-01
In light of increasing interest in evidence-based management, we conducted a scoping review of systematic reviews (SRs) and meta-analyses (MAs) to determine the availability and accessibility of evidence for health care managers; 14 MAs and 61 SRs met the inclusion criteria. Most reviews appeared in medical journals (53%), originated in the United States (29%) or United Kingdom (22%), were hospital-based (55%), and targeted clinical providers (55%). Topics included health services organization (34%), quality/patient safety (17%), information technology (15%), organization/workplace management (13%), and health care workforce (12%). Most reviews addressed clinical topics of relevance to managers; management-related interventions were rare. The management issues were mostly classified as operational (65%). Surprisingly, 96.5% of search results were not on target. A better classification within PubMed is needed to increase the accessibility of meaningful resources and facilitate evidence retrieval. Health care journals should take initiatives encouraging the publication of reviews in relevant management areas. © The Author(s) 2013.
CPAP Pressure for Prediction of Oral Appliance Treatment Response in Obstructive Sleep Apnea
Sutherland, Kate; Phillips, Craig L.; Davies, Amanda; Srinivasan, Vasanth K.; Dalci, Oyku; Yee, Brendon J.; Darendeliler, M. Ali; Grunstein, Ronald R.; Cistulli, Peter A.
2014-01-01
Study Objectives: Mandibular advancement splints (MAS) are often preferred to CPAP treatment for OSA but are not always equally efficacious. High therapeutic CPAP pressure has been associated with MAS treatment failure in a Japanese population. We sought to assess the relationship between CPAP pressure and MAS treatment response in an Australian population. Methods: Therapeutic CPAP pressure and MAS treatment response were obtained from a one-month crossover trial of both treatments. Predictive utility of CPAP pressure to identify MAS treatment response was assessed. Results: Seventy-eight OSA patients were included (age 49.3 ± 11.1 years, BMI 29.1 ± 5.8 kg/m2) with predominantly moderate-severe OSA (AHI 30.0 ± 12.7/h). CPAP pressure was lower in MAS responders (MAS AHI < 10/h) 9.7 ± 1.6 vs. 11.7 ± 2.4 cm H O, p < 0.01, with area under ROC curve of 0.74 (95% CI 0.63-0.86), p < 0.01. The best cutoff value of 10.5 cm H O useful for discriminating MAS responders and non-responders in the previous Japanese population, was inadequate for prediction in the current population (0.47 negative predictive value [NPV]). However a cutoff of 13 cm H O identified MAS non-responders (1.0 NPV). Multivariate regression identified CPAP pressure (odds ratio [95% confidence interval] 0.53 [0.33-0.87], age (0.93 [0.87-0.99]) and AHI (0.92 [0.86-0.97]) as predictors of MAS treatment response (model r2 = 0.54, p < 0.001). Conclusions: In Australian patients, the majority of whom are Caucasian, a higher therapeutic CPAP pressure requirement in conjunction with age and OSA severity characteristics may be useful to indicate likelihood of success with MAS as an alternative therapy. Citation: Sutherland K, Phillips CL, Davies A, Srinivasan VK, Dalci O, Yee BJ, Darendeliler MA, Grunstein RR, Cistulli PA. CPAP pressure for prediction of oral appliance treatment response in obstructive sleep apnea. J Clin Sleep Med 2014;10(9):943-949. PMID:25142773
Leicht, Simon F; Kernt, Marcus; Neubauer, Aljoscha; Wolf, Armin; Oliveira, Carlos Manta; Ulbig, Michael; Haritoglou, Christos
2014-01-01
To evaluate the influence of a ranibizumab treatment on microaneurysm (MA) turnover in diabetic retinopathy. Sixty-nine eyes were included in this retrospective study. We compared a group of 33 eyes with ranibizumab treatment for diabetic macular edema to 36 eyes with nonproliferative diabetic retinopathy only. Nonmydriatic ultra-widefield scanning laser ophthalmoscopy (Optomap) images were obtained at a mean 4.76 ± 1.69 days prior to the first ranibizumab injection (baseline) and again 35.94 ± 2.44 days after the third consecutive injection in a 4-week interval. In untreated controls, images were obtained at baseline and 97.81 ± 3.16 days thereafter. Images were analyzed using the RetmarkerDR software (Critical Health SA, Coimbra, Portugal), and the turnover of MAs was documented and analyzed. Thereafter, MA turnover was correlated with central retinal thickness (CRT) as assessed by OCT. At baseline, patients in the treatment group had 5.64 ± 0.75 MAs. One month after 3 ranibizumab injections, measured MAs decreased to 4.03 ± 0.66. In the untreated control group, the initial number of 3.36 ± 0.6 MAs remained almost unchanged over 3-4 months (2.89 ± 0.57 MAs). Dynamic analysis showed that after ranibizumab treatment 3.06 ± 0.5 new MAs appeared, while 5.09 ± 0.79 disappeared. In the control group, 2.11 ± 0.4 new MAs appeared and 2.61 ± 0.48 disappeared. MA turnover was significantly higher with ranibizumab compared to the control group (8.15 ± 1.14 vs. 4.72 ± 0.81, p < 0.001). Consistently, CRT decreased from 444 to 330 µm in the ranibizumab group, while there was no change in the control group (291 vs. 288 µm). The treatment of macular edema using ranibizumab does not only reduce macular thickness, but also has an impact on the turnover of MAs in diabetic retinopathy. RetmarkerDR analysis showed that more pre-existent MAs disappeared than new MAs developed, and the absolute number of MAs also decreased. © 2014 S. Karger AG, Basel.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sevelsted, Tine F.; Herfort, Duncan; Skibsted, Jørgen, E-mail: jskib@chem.au.dk
2013-10-15
{sup 13}C isotropic chemical shifts and chemical shift anisotropy parameters have been determined for a number of inorganic carbonates relevant in cement chemistry from slow-speed {sup 13}C MAS or {sup 13}C({sup 1}H) CP/MAS NMR spectra (9.4 T or 14.1 T) for {sup 13}C in natural abundance. The variation in the {sup 13}C chemical shift parameters is relatively small, raising some doubts that different carbonate species in Portland cement-based materials may not be sufficiently resolved in {sup 13}C MAS NMR spectra. However, it is shown that by combining {sup 13}C MAS and {sup 13}C({sup 1}H) CP/MAS NMR carbonate anions in anhydrousmore » and hydrated phases can be distinguished, thereby providing valuable information about the reactivity of limestone in cement blends. This is illustrated for three cement pastes prepared from an ordinary Portland cement, including 0, 16, and 25 wt.% limestone, and following the hydration for up to one year. For these blends {sup 29}Si MAS NMR reveals that the limestone filler accelerates the hydration for alite and also results in a smaller fraction of tetrahedrally coordinated Al incorporated in the C-S-H phase. The latter result is more clearly observed in {sup 27}Al MAS NMR spectra of the cement–limestone blends and suggests that dissolved aluminate species in the cement–limestone blends readily react with carbonate ions from the limestone filler, forming calcium monocarboaluminate hydrate. -- Highlights: •{sup 13}C chemical shift anisotropies for inorganic carbonates from {sup 13}C MAS NMR. •Narrow {sup 13}C NMR chemical shift range (163–171 ppm) for inorganic carbonates. •Anhydrous and hydrated carbonate species by {sup 13}C MAS and {sup 13}C({sup 1}H) CP/MAS NMR. •Limestone accelerates the hydration for alite in Portland – limestone cements. •Limestone reduces the amount of aluminium incorporated in the C-S-H phase.« less
NASA Astrophysics Data System (ADS)
Fukushima, Toshio
2003-07-01
We adapt J. G. Williams' expression of the precession and nutation using the 3-1-3-1 rotation to an arbitrary inertial frame of reference. The modified formulation avoids a singularity caused by finite pole offsets near the epoch. By adopting the planetary precession formula numerically determined from DE405 and by using a recent theory of the forced nutation of the nonrigid Earth by Shirai & Fukishima, we analyze the celestial pole offsets observed by VLBI for 1979-2000 and determine the best-fit polynomials of the lunisolar precession angles. We then translate the results into classical precession quantities and evaluate the difference due to the difference in the ecliptic definition. The combination of these formulae and the periodic part of the Shirai-Fukishima nutation theory serves as a good approximation of the precession-nutation matrix in the International Celestial Reference Frame. As a by-product, we determine the mean celestial pole offset at J2000.0 as X0=-(17.12+/-0.01) mas and Y0=-(5.06+/-0.02) mas. Also, we estimate the speed of general precession in longitude at J2000.0 as p=5028.7955"+/-0.0003" per Julian century, the mean obliquity at J2000.0 in the inertial sense as (ɛ0)I=84381.40621"+/-0.00001" and in the rotational sense as (ɛ0)R=84381.40955"+/-0.00001", and the dynamical flattening of Earth as Hd=(3.2737804+/-0.0000003)×10-3. Furthermore, we establish a fast way to compute the precession-nutation matrix and provide a best-fit polynomial of an angle to specify the mean Celestial Ephemeris Origin.
Marschner, Karel; Musil, Stanislav; Dědina, Jiří
2016-04-05
An experimental setup consisting of a flow injection hydride generator coupled to an atomic fluorescence spectrometer was optimized in order to generate arsanes from tri- and pentavalent inorganic arsenic species (iAs(III), iAs(V)), monomethylarsonic acid (MAs(V)), and dimethylarsinic acid (DMAs(V)) with 100% efficiency with the use of only HCl and NaBH4 as the reagents. The optimal concentration of HCl was 2 mol L(-1); the optimal concentration of NaBH4 was 2.5% (m/v), and the volume of the reaction coil was 8.9 mL. To prevent excessive signal noise due to fluctuations of hydride supply to an atomizer, a new design of a gas-liquid separator was implemented. The optimized experimental setup was subsequently interfaced to HPLC and employed for speciation analysis of arsenic. Two chromatography columns were tested: (i) ion-pair chromatography and (ii) ion exchange chromatography. The latter offered much better results for human urine samples without a need for sample dilution. Due to the equal hydride generation efficiency (and thus the sensitivities) of all As species, a single species standardization by DMAs(V) standard was feasible. The limits of detection for iAs(III), iAs(V), MAs(V), and DMAs(V) were 40, 97, 57, and 55 pg mL(-1), respectively. Accuracy of the method was tested by the analysis of the standard reference material (human urine NIST 2669), and the method was also verified by the comparative analyses of human urine samples collected from five individuals with an independent reference method.
Idris, Ghassan; Galland, Barbara; Robertson, Christopher J; Farella, Mauro
2016-01-01
Sleep-Disordered Breathing (SDB) varies from habitual snoring to partial or complete obstruction of the upper airway and can be found in up to 10% of children. SDB can significantly affect children's wellbeing, as it can cause growth disorders, educational and behavioral problems, and even life-threatening conditions, such as cardiorespiratory failure. Adenotonsillectomy represents the primary treatment for pediatric SDB where adeno-tonsillar hypertrophy is indicated. For those with craniofacial anomalies, or for whom adenotonsillectomy or other treatment modalities have failed, or surgery is contra-indicated, mandibular advancement splints (MAS) may represent a viable treatment option. Whilst the efficacy of these appliances has been consistently demonstrated in adults, there is little information about their effectiveness in children. To determine the efficacy of mandibular advancement appliances for the management of SDB and related health problems in children. The study will be designed as a single-blind crossover randomized controlled trial with administration of both an "Active MAS" (Twin-block) and a "Sham MAS." Eligible participants will be children aged 8-12 years whose parents report they snore ≥3 nights per week. Sixteen children will enter the full study after confirming other inclusion criteria, particularly Skeletal class I or class II confirmed by lateral cephalometric radiograph. Each child will be randomly assigned to either a treatment sequence starting with the Active or the Sham MAS. Participants will wear the appliances for 3 weeks separated by a 2-week washout period. For each participant, home-based polysomnographic data will be collected four times; once before and once after each treatment period. The Apnea Hypopnea Index (AHI) will represent the main outcome variable. Secondary outcomes will include, snoring frequency, masseter muscle activity, sleep symptoms, quality of life, daytime sleepiness, children behavior, and nocturnal enuresis. In addition, blood samples will be collected to assess growth hormone changes. This study was registered in the Australian New Zealand Clinical Trials Registry (ANZCTR): [ACTRN12614001013651].
Perla, M E; Rue, Tessa; Cheadle, Allen; Krieger, James; Karr, Catherine J; Karr, C K
2015-06-01
Differences in cultural and economic status may place ethnic subgroups of children at higher risk for exposure, leading to heightened health risks, and health inequities. Although Latino-Americans represent 22% of all children in the United States, few studies have explored within-group differences in their exposure to toxicants. Using socio-demographic and biomarker data from the National Health and Nutrition Examination Survey from 1999 to 2008, we characterized determinants of health and estimated geometric means of environmental contaminant biomarkers (blood concentrations of lead and mercury, serum concentrations of dichlorodiphenyldichloroethylene [p,p'-DDE] and cotinine, and urinary metabolites of organophosphate [OP] pesticides and polycyclic aromatic hydrocarbons [PAHs]) among 4,257 Mexican American (MA), 677 Other Latino-American (OL), and 3,370 Non-Hispanic White (NHW) children. MAs had the lowest levels of health insurance coverage and regular access to health care, and largest household size compared to NHWs and OLs. MAs had higher levels of p,p'-DDE, lead, and cadmium while OLs had higher estimates of mercury relative to other groups. MAs had higher urinary metabolite concentrations of 2-hydroxynaphthalene; otherwise MAs and OLs had lower concentrations of PAHs. NHWs had higher levels of cotinine and dimethylthiophosphate. For other OP metabolites, differences among groups were less clear. Lead and p,p'-DDE exposure differences likely reflect later and less regulatory control of these chemicals in Latin America. Additionally, poor quality housing with lead paint is more common in economically disadvantaged subpopulations. Dietary habits are possible sources of differential cadmium, mercury, and organophosphate exposure. Cotinine exposure differences by income and U.S.- vs. foreign-born may represent increased acculturation. These results, coupled with additional research on exposure sources may contribute to refinement of environmental health promotion programs for the fast-growing Latino-American population.
Scholz, Karoline; Dekant, Wolfgang; Völkel, Wolfgang; Pähler, Axel
2005-12-01
A sensitive and specific liquid chromatography-mass spectrometry (LC-MS) method based on the combination of constant neutral loss scans (CNL) with product ion scans was developed on a linear ion trap. The method is applicable for the detection and identification of analytes with identical chemical substructures (such as conjugates of xenobiotics formed in biological systems) which give common CNLs. A specific CNL was observed for thioethers of N-acetyl-L-cysteine (mercapturic acids, MA) by LC-MS/MS. MS and HPLC parameters were optimized with 16 MAs available as reference compounds. All of these provided a CNL of 129 Da in the negative-ion mode. To assess sensitivity, a multiple reaction monitoring (MRM) mode with 251 theoretical transitions using the CNL of 129 Da combined with a product ion scan (IDA thMRM) was compared with CNL combined with a product ion scan (IDA CNL). An information-dependent acquisition (IDA) uses a survey scan such as MRM (multiple reaction monitoring) to generate "informations" and starting a second acquisition experiment such as a product ion scan using these "informations." Th-MRM means calculated transitions and not transitions generated from an available standard in the tuning mode. The product ion spectra provide additional information on the chemical structure of the unknown analytes. All MA standards were spiked in low concentrations to rat urines and were detected with both methods with LODs ranging from 60 pmol/mL to 1.63 nmol/mL with IDA thMRM. The expected product ion spectra were observed in urine. Application of this screening method to biological samples indicated the presence of a number of MAs in urine of unexposed rats, and resulted in the identification of 1,4-dihydroxynonene mercapturic acid as one of these MAs by negative and positive product ion spectra. These results show that the developed methods have a high potential to serve as both a prescreen to detect unknown MAs and to identify these analytes in complex matrix.
Radiation dose reduction for CT lung cancer screening using ASIR and MBIR: a phantom study.
Mathieu, Kelsey B; Ai, Hua; Fox, Patricia S; Godoy, Myrna Cobos Barco; Munden, Reginald F; de Groot, Patricia M; Pan, Tinsu
2014-03-06
The purpose of this study was to reduce the radiation dosage associated with computed tomography (CT) lung cancer screening while maintaining overall diagnostic image quality and definition of ground-glass opacities (GGOs). A lung screening phantom and a multipurpose chest phantom were used to quantitatively assess the performance of two iterative image reconstruction algorithms (adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR)) used in conjunction with reduced tube currents relative to a standard clinical lung cancer screening protocol (51 effective mAs (3.9 mGy) and filtered back-projection (FBP) reconstruction). To further assess the algorithms' performances, qualitative image analysis was conducted (in the form of a reader study) using the multipurpose chest phantom, which was implanted with GGOs of two densities. Our quantitative image analysis indicated that tube current, and thus radiation dose, could be reduced by 40% or 80% from ASIR or MBIR, respectively, compared with conventional FBP, while maintaining similar image noise magnitude and contrast-to-noise ratio. The qualitative portion of our study, which assessed reader preference, yielded similar results, indicating that dose could be reduced by 60% (to 20 effective mAs (1.6 mGy)) with either ASIR or MBIR, while maintaining GGO definition. Additionally, the readers' preferences (as indicated by their ratings) regarding overall image quality were equal or better (for a given dose) when using ASIR or MBIR, compared with FBP. In conclusion, combining ASIR or MBIR with reduced tube current may allow for lower doses while maintaining overall diagnostic image quality, as well as GGO definition, during CT lung cancer screening.
SU-F-J-16: Planar KV Imaging Dose Reduction Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gershkevitsh, E; Zolotuhhin, D
Purpose: IGRT has become an indispensable tool in modern radiotherapy with kV imaging used in many departments due to superior image quality and lower dose when compared to MV imaging. Many departments use manufacturer supplied protocols for imaging which are not always optimised between image quality and radiation dose (ALARA). Methods: Whole body phantom PBU-50 (Kyoto Kagaku ltd., Japan) for imaging in radiology has been imaged on Varian iX accelerator (Varian Medical Systems, USA) with OBI 1.5 system. Manufacturer’s default protocols were adapted by modifying kV and mAs values when imaging different anatomical regions of the phantom (head, thorax, abdomen,more » pelvis, extremities). Images with different settings were independently reviewed by two persons and their suitability for IGRT set-up correction protocols were evaluated. The suitable images with the lowest mAs were then selected. The entrance surface dose (ESD) for manufacturer’s default protocols and modified protocols were measured with RTI Black Piranha (RTI Group, Sweden) and compared. Image quality was also measured with kVQC phantom (Standard Imaging, USA) for different protocols. The modified protocols have been applied for clinical work. Results: For most cases optimized protocols reduced the ESD on average by a factor of 3(range 0.9–8.5). Further reduction in ESD has been observed by applying bow-tie filter designed for CBCT. The largest reduction in dose (12.2 times) was observed for Thorax lateral protocol. The dose was slightly increased (by 10%) for large pelvis AP protocol. Conclusion: Manufacturer’s default IGRT protocols could be optimised to reduce the ESD to the patient without losing the necessary image quality for patient set-up correction. For patient set-up with planar kV imaging the bony anatomy is mostly used and optimization should focus on this aspect. Therefore, the current approach with anthropomorphic phantom is more advantageous in optimization over standard kV quality control phantoms and SNR metrics.« less
Fast passage dynamic nuclear polarization on rotating solids.
Mentink-Vigier, Frederic; Akbey, Umit; Hovav, Yonatan; Vega, Shimon; Oschkinat, Hartmut; Feintuch, Akiva
2012-11-01
Magic Angle Spinning (MAS) Dynamic Nuclear Polarization (DNP) has proven to be a very powerful way to improve the signal to noise ratio of NMR experiments on solids. The experiments have in general been interpreted considering the Solid-Effect (SE) and Cross-Effect (CE) DNP mechanisms while ignoring the influence of sample spinning. In this paper, we show experimental data of MAS-DNP enhancements of (1)H and (13)C in proline and SH3 protein in glass forming water/glycerol solvent containing TOTAPOL. We also introduce a theoretical model that aims at explaining how the nuclear polarization is built in MAS-DNP experiments. By using Liouville space based simulations to include relaxation on two simple spin models, {electron-nucleus} and {electron-electron-nucleus}, we explain how the basic MAS-SE-DNP and MAS-CE-DNP processes work. The importance of fast energy passages and short level anti-crossing is emphasized and the differences between static DNP and MAS-DNP is explained. During a single rotor cycle the enhancement in the {electron-electron-nucleus} system arises from MAS-CE-DNP involving at least three kinds of two-level fast passages: an electron-electron dipolar anti-crossing, a single quantum electron MW encounter and an anti-crossing at the CE condition inducing nuclear polarization in- or decrements. Numerical, powder-averaged, simulations were performed in order to check the influence of the experimental parameters on the enhancement efficiencies. In particular we show that the spinning frequency dependence of the theoretical MAS-CE-DNP enhancement compares favorably with the experimental (1)H and (13)C MAS-DNP enhancements of proline and SH3. Copyright © 2012 Elsevier Inc. All rights reserved.
Patterns of Relating Between Physicians and Medical Assistants in Small Family Medicine Offices
Elder, Nancy C.; Jacobson, C. Jeffrey; Bolon, Shannon K.; Fixler, Joseph; Pallerla, Harini; Busick, Christina; Gerrety, Erica; Kinney, Dee; Regan, Saundra; Pugnale, Michael
2014-01-01
PURPOSE The clinician-colleague relationship is a cornerstone of relationship-centered care (RCC); in small family medicine offices, the clinician–medical assistant (MA) relationship is especially important. We sought to better understand the relationship between MA roles and the clinician-MA relationship within the RCC framework. METHODS We conducted an ethnographic study of 5 small family medicine offices (having <5 clinicians) in the Cincinnati Area Research and Improvement Group (CARInG) Network using interviews, surveys, and observations. We interviewed 19 MAs and supervisors and 11 clinicians (9 family physicians and 2 nurse practitioners) and observed 15 MAs in practice. Qualitative analysis used the editing style. RESULTS MAs’ roles in small family medicine offices were determined by MA career motivations and clinician-MA relationships. MA career motivations comprised interest in health care, easy training/workload, and customer service orientation. Clinician-MA relationships were influenced by how MAs and clinicians respond to their perceptions of MA clinical competence (illustrated predominantly by comparing MAs with nurses) and organizational structure. We propose a model, trust and verify, to describe the structure of the clinician-MA relationship. This model is informed by clinicians’ roles in hiring and managing MAs and the social familiarity of MAs and clinicians. Within the RCC framework, these findings can be seen as previously undefined constraints and freedoms in what is known as the Complex Responsive Process of Relating between clinicians and MAs. CONCLUSIONS Improved understanding of clinician-MA relationships will allow a better appreciation of how clinicians and MAs function in family medicine teams. Our findings may assist small offices undergoing practice transformation and guide future research to improve the education, training, and use of MAs in the family medicine setting. PMID:24615311
Tubaş, Filiz; Per, Sedat; Taşdemir, Abdulkadir; Bayram, Ayşe Kaçar; Yıldırım, Mehmet; Uzun, Aydın; Saraymen, Recep; Gümüş, Hakan; Elmalı, Ferhan; Per, Hüseyin
2017-01-01
Traditionally, Morus rubra L. (Moraceae) (red mulberry) and Cornus mas L. (Cornacea) (cornelian cherry) fruits are eaten fresh and are also used in marmalades, juices, jam, natural dyes in Turkey and are believed to have beneficial effects in case of multiple health issues such as antipyretic, diarrhea and intestinal parasites. However, the effects of M. rubra and C. mas on epilepsy has not been known. This study evaluates the effects of M. rubra and C. mas extracts on penicillin-induced epileptiform activity. Sixty Wistar rats randomly divided into ten groups (n=6): control, sham, penicillin, penicillin+M. rubra extract (2.5, 5, 10, 20 mg/kg) and penicillin+C. mas extract (2.5, 5, 10 mg/kg). Epileptiform activity was induced by using penicillin (500 IU, i.c.) and electrocorticogram records (150 min) were obtained. Also, biochemical analysis in blood samples were evaluated. According to the electrocorticogram analysis, the effective dose was detected as 10 mg/kg for both C. mas and M. rubra. This dose decreased the spike frequencies of convulsions while amplitude wasn't changed by both substances. In erythrocyte studies, there were significant differences regarding nitric oxide in the control, sham and penicillin groups. There were significant differences regarding malondialdehyde in all groups. In the plasma, there were significant differences among groups regarding xanthine oxidase in the penicillin‑C. mas and penicillin‑M. rubra groups. There were differences regarding malondialdehyde in the penicillin-C. mas and M. rubra-C. mas groups. Both extracts reduced the frequency of epileptiform activity. After administration of the extracts malondialdehyde levels decreased also in both erythrocytes and plasma.
Rapid estimation of 4DCT motion-artifact severity based on 1D breathing-surrogate periodicity
Li, Guang; Caraveo, Marshall; Wei, Jie; Rimner, Andreas; Wu, Abraham J.; Goodman, Karyn A.; Yorke, Ellen
2014-01-01
Purpose: Motion artifacts are common in patient four-dimensional computed tomography (4DCT) images, leading to an ill-defined tumor volume with large variations for radiotherapy treatment and a poor foundation with low imaging fidelity for studying respiratory motion. The authors developed a method to estimate 4DCT image quality by establishing a correlation between the severity of motion artifacts in 4DCT images and the periodicity of the corresponding 1D respiratory waveform (1DRW) used for phase binning in 4DCT reconstruction. Methods: Discrete Fourier transformation (DFT) was applied to analyze 1DRW periodicity. The breathing periodicity index (BPI) was defined as the sum of the largest five Fourier coefficients, ranging from 0 to 1. Distortional motion artifacts (excluding blurring) of cine-scan 4DCT at the junctions of adjacent couch positions around the diaphragm were classified in three categories: incomplete, overlapping, and duplicate anatomies. To quantify these artifacts, discontinuity of the diaphragm at the junctions was measured in distance and averaged along six directions in three orthogonal views. Artifacts per junction (APJ) across the entire diaphragm were calculated in each breathing phase and phase-averaged APJ¯, defined as motion-artifact severity (MAS), was obtained for each patient. To make MAS independent of patient-specific motion amplitude, two new MAS quantities were defined: MASD is normalized to the maximum diaphragmatic displacement and MASV is normalized to the mean diaphragmatic velocity (the breathing period was obtained from DFT analysis of 1DRW). Twenty-six patients’ free-breathing 4DCT images and corresponding 1DRW data were studied. Results: Higher APJ values were found around midventilation and full inhalation while the lowest APJ values were around full exhalation. The distribution of MAS is close to Poisson distribution with a mean of 2.2 mm. The BPI among the 26 patients was calculated with a value ranging from 0.25 to 0.93. The DFT calculation was within 3 s per 1DRW. Correlations were found between 1DRW periodicity and 4DCT artifact severity: −0.71 for MASD and −0.73 for MASV. A BPI greater than 0.85 in a 1DRW suggests minimal motion artifacts in the corresponding 4DCT images. Conclusions: The breathing periodicity index and motion-artifact severity index are introduced to assess the relationship between 1DRW and 4DCT. A correlation between 1DRW periodicity and 4DCT artifact severity has been established. The 1DRW periodicity provides a rapid means to estimate 4DCT image quality. The rapid 1DRW analysis and the correlative relationship can be applied prospectively to identify irregular breathers as candidates for breath coaching prior to 4DCT scan and retrospectively to select high-quality 4DCT images for clinical motion-management research. PMID:25370631
Marker-assisted selection in plant breeding for salinity tolerance.
Ashraf, M; Akram, N A; Mehboob-Ur-Rahman; Foolad, M R
2012-01-01
Marker-assisted selection (MAS) is the process of using morphological, biochemical, or DNA markers as indirect selection criteria for selecting agriculturally important traits in crop breeding. This process is used to improve the effectiveness or efficiency of selection for the traits of interest in breeding programs. The significance of MAS as a tool for crop improvement has been extensively investigated in different crop -species and for different traits. The use of MAS for manipulating simple/qualitative traits is straightforward and has been well reported. However, MAS for the improvement of complex/polygenic traits, including plant tolerance/resistance to abiotic stresses, is more complicated, although its usefulness has been recognized. With the recent advances in marker technology, including high-throughput genotyping of plants, together with the development of nested association mapping populations, it is expected that the utility of MAS for breeding for stress tolerance traits will increase. In this chapter, we describe the basic procedure for using MAS in crop breeding for salt tolerance.
Classification of adaptive memetic algorithms: a comparative study.
Ong, Yew-Soon; Lim, Meng-Hiot; Zhu, Ning; Wong, Kok-Wai
2006-02-01
Adaptation of parameters and operators represents one of the recent most important and promising areas of research in evolutionary computations; it is a form of designing self-configuring algorithms that acclimatize to suit the problem in hand. Here, our interests are on a recent breed of hybrid evolutionary algorithms typically known as adaptive memetic algorithms (MAs). One unique feature of adaptive MAs is the choice of local search methods or memes and recent studies have shown that this choice significantly affects the performances of problem searches. In this paper, we present a classification of memes adaptation in adaptive MAs on the basis of the mechanism used and the level of historical knowledge on the memes employed. Then the asymptotic convergence properties of the adaptive MAs considered are analyzed according to the classification. Subsequently, empirical studies on representatives of adaptive MAs for different type-level meme adaptations using continuous benchmark problems indicate that global-level adaptive MAs exhibit better search performances. Finally we conclude with some promising research directions in the area.
Marker-assisted selection: an approach for precision plant breeding in the twenty-first century.
Collard, Bertrand C Y; Mackill, David J
2008-02-12
DNA markers have enormous potential to improve the efficiency and precision of conventional plant breeding via marker-assisted selection (MAS). The large number of quantitative trait loci (QTLs) mapping studies for diverse crops species have provided an abundance of DNA marker-trait associations. In this review, we present an overview of the advantages of MAS and its most widely used applications in plant breeding, providing examples from cereal crops. We also consider reasons why MAS has had only a small impact on plant breeding so far and suggest ways in which the potential of MAS can be realized. Finally, we discuss reasons why the greater adoption of MAS in the future is inevitable, although the extent of its use will depend on available resources, especially for orphan crops, and may be delayed in less-developed countries. Achieving a substantial impact on crop improvement by MAS represents the great challenge for agricultural scientists in the next few decades.
Dynamics of foam flow in porous media in the presence of oil
NASA Astrophysics Data System (ADS)
Shokri, N.; Osei-Bonsu, K.
2016-12-01
Foams demonstrate great potential for fluid displacement in porous media which is important in a number of subsurface operations such as the enhanced oil recovery and soil remediation. The application of foam in these processes is down to its unique ability to reduce gas mobility by increasing its effective viscosity and to divert gas to un-swept low permeability zones in porous media [1-4]. To investigate the fundamental aspects of foam flow in porous media, we have conducted a systematic series of experiment using a well-characterised porous medium manufactured by a high resolution 3D printer. This enabled us to design and control the properties of porous media with high accuracy. The model porous medium was initially saturated with oil. Then the pre-generated foam was injected into the model at well-defined injection rates to displace oil. The dynamics of foam-oil displacement in porous media was recorded using a digital camera controlled by a computer [5]. The recorded images were analysed in MATLAB to determine the dynamics of foam-oil displacement under different boundary conditions. Effects of the type of oil, foam quality and foam flow rate were investigated. Our results reveal that generation of stable foam is delayed in the presence of light oil in the porous medium compared to the heavy oil. Furthermore, higher foam quality appears to be less stable in the presence of oil lowering its recovery efficiency. Pore-scale inspection of foam-oil patterns formed during displacement revealed formation of a more stable front in the case of lower foam quality which affected the oil recovery efficiency. This study extends the physical understanding of governing mechanisms controlling oil displacement by foam in porous media. Grassia, P., E. Mas-Hernandez, N. Shokri, S.J. Cox, G. Mishuris, W.R. Rossen (2014), J. Fluid Mech., 751, 346-405. Grassia, P., C. Torres-Ulloa, S. Berres, E. Mas-Hernandez, N. Shokri (2016), European Physical Journal E, 39 (4), 42. Mas-Hernandez, E., P. Grassia, N. Shokri (2015), Colloids and Surfaces A: Physicochem. Eng. Aspects, 473, 123-132. Osei-Bonsu, K., N. Shokri, P. Grassia (2015), Colloids and Surfaces A: Physicochem. Eng. Aspects, 481, 514-526. Osei-Bonsu, K., N. Shokri, P. Grassia (2016), J. Colloid Interface Sci., 462, 288-296.
Meconium Aspiration Syndrome: A Role for Fetal Systemic Inflammation
LEE, JoonHo; ROMERO, Roberto; LEE, Kyung A; KIM, Eun Na; KORZENIEWSKI, Steven J; CHAEMSAITHONG, Piya; YOON, Bo Hyun
2017-01-01
Background Meconium aspiration syndrome (MAS) is a leading cause of morbidity and mortality in term infants. Meconium-stained amniotic fluid (MSAF) occurs in approximately one of every seven pregnancies, but only 5% of neonates exposed to MSAF develop MAS. Why some infants exposed to meconium develop MAS while others do not is a fundamental question. Patients with MSAF have a higher frequency of intra-amniotic infection/inflammation than those with clear fluid. We propose that fetal systemic inflammation is a risk factor for the development of MAS in patients with MSAF. Objective To investigate whether intra-amniotic inflammation and funisitis, the histopathologic landmark of a fetal inflammatory response, predispose to MAS. Study Design A prospective cohort study was conducted from 1995 through 2009. Amniotic fluid (AF) samples (n=1,281) were collected at the time of cesarean delivery from women who delivered singleton newborns at term (gestational age ≥38 weeks). Intra-amniotic inflammation was diagnosed if the AF concentration of matrix metalloproteinase-8 (MMP-8) was >23 ng/ml. Funisitis was diagnosed by histologic examination if inflammation was present in the umbilical cord. Results The prevalence of MSAF was 9.2% (118/1,281), and 10.2% (12/118) of neonates exposed to MSAF developed MAS. There were no significant differences in the median gestational age or umbilical cord arterial pH at birth between neonates who developed MAS and those who did not (each p > 0.1). Mothers whose newborns developed MAS had a higher median AF MMP-8 (456.8 ng/ml vs.157.2 ng/ml; p < 0.05). Newborns exposed to intra-amniotic inflammation had a higher rate of MAS than those who were not exposed to intra-amniotic inflammation [13.0% (10/77) vs. 0% (0/32), p = 0.03], as did those exposed to funisitis [31.3% (5/16) vs. 7.3% (6/82), relative risk, 4.3; 95% confidence interval, 1.5–12.3]. Among the 89 newborns for whom both AF and placental histology were available, MAS was more common in patients with both intra-amniotic inflammation and funisitis than in those without intra-amniotic inflammation and funisitis [28.6% (4/14) vs. 0% (0/28), p = 0.009], while the rate of MAS did not show a significant difference between patients with intra-amniotic inflammation alone (without funisitis) and those without intra-amniotic inflammation and funisitis [10.9% (5/46) vs. 0% (0/28)]. Conclusion The combination of intra-amniotic inflammation with fetal systemic inflammation is an important antecedent of MAS. This concept has implications for the understanding of the mechanisms of disease responsible for MAS and for the development of prognostic models and therapeutic interventions for this disorder. PMID:26484777
Prost, Stephanie Grace; Ai, Amy L; Ainsworth, Sarah E; Ayers, Jaime
2016-01-01
Adult obesity in the United States has risen to epidemic proportions, and mental health professionals must be called to action. The objectives of this article were to (a) synthesize outcomes of behavioral health interventions for adult obesity in recent meta-analyses and systematic reviews (MAs/SRs) as well as randomized controlled trials (RCTs) and further, (b) evaluate the role of mental health professionals in these behavioral health interventions. Articles were included if published in English between January 1, 2004, and May 1, 2014, in peer-reviewed journals examining behavioral health interventions for adults with obesity. Data were subsequently extracted and independently checked by two authors. Included MAs/SRs utilized motivational interviewing, financial incentives, multicomponent behavioral weight management programs, as well as dietary and lifestyle interventions. Behavioral health interventions in randomized controlled trials (RCTs) were discussed across 3 major intervention types (educational, modified caloric intake, cognitive-based). Regarding the 1st study objective, multiple positive primary (e.g., weight loss) and secondary outcomes (e.g., quality of life) were found in both MAs/SRs and RCTs. However, the majority of included studies made no mention of interventionist professional background and little inference could be made regarding the effects of professional background on behavioral health intervention outcomes for adults facing obesity; an important limitation and direction for future research. Future studies should assess the effects of interventionist profession in addition to primary and secondary outcomes for adults facing obesity. Implications for mental health professionals' educational curricula, assessment, and treatment strategies are discussed.
Low dose CT perfusion in acute ischemic stroke.
Murphy, Amanda; So, Aaron; Lee, Ting-Yim; Symons, Sean; Jakubovic, Raphael; Zhang, Liying; Aviv, Richard I
2014-12-01
The purpose of this investigation is to determine if CT perfusion (CTP) measurements at low doses (LD = 20 or 50 mAs) are similar to those obtained at regular doses (RD = 100 mAs), with and without the addition of adaptive statistical iterative reconstruction (ASIR). A single-center, prospective study was performed in patients with acute ischemic stroke (n = 37; 54% male; age = 74 ± 15 years). Two CTP scans were performed on each subject: one at 100 mAs (RD) and one at either 50 or 20 mAs (LD). CTP parameters were compared between the RD and LD scans in regions of ischemia, infarction, and normal tissue. Differences were determined using a within-subjects ANOVA (p < 0.05) followed by a paired t test post hoc analysis (p < 0.01). At 50 mAs, there was no significant difference between cerebral blood flow (CBF), cerebral blood volume (CBV), or time to maximum enhancement (Tmax) values for the RD and LD scans in the ischemic, infarcted, or normal contralateral regions (p < 0.05). At 20 mAs, there were significant differences between the RD and LD scans for all parameters in the ischemic and normal tissue regions (p > 0.05). CTP-derived CBF and CBV are not different at 50 mAs compared to 100 mAs, even without the addition of ASIR. Current CTP protocols can be modified to reduce the effective dose by 50 % without altering CTP measurements.
Precise predictions of stellar occultations by Pluto, Charon, Nix, and Hydra for 2008-2015
NASA Astrophysics Data System (ADS)
Assafin, M.; Camargo, J. I. B.; Vieira Martins, R.; Andrei, A. H.; Sicardy, B.; Young, L.; da Silva Neto, D. N.; Braga-Ribas, F.
2010-06-01
Context. We investigate transneptunian objects, including Pluto and its satellites, by stellar occultations. Aims: Our aim is to derive precise, astrometric predictions for stellar occultations by Pluto and its satellites Charon, Hydra and Nix for 2008-2015. We construct an astrometric star catalog in the UCAC2 system covering Plutoarcmins sky path. Methods: We carried out in 2007 an observational program at the ESO2p2/WFI instrument covering the sky path of Pluto from 2008 to 2015. We made the astrometry of 110 GB of images with the Platform for Reduction of Astronomical Images Automatically (PRAIA). By relatively simple astrometric techniques, we treated the overlapping observations and derived a field distortion pattern for the WFI mosaic of CCDs to within 50 mas precision. Results: Positions were obtained in the UCAC2 frame with errors of 50 mas for stars up to magnitude R = 19, and 25 mas up to R = 17. New stellar proper motions were also determined with 2MASS and the USNO B1.0 catalog positions as first epoch. We generated 2252 predictions of stellar occultations by Pluto, Charon, Hydra and Nix for 2008-2015. An astrometric catalog with proper motions was produced, containing 2.24 million stars covering Plutoarcmins sky path with 30arcmin width. Its magnitude completeness is about R = 18-19 with a limit about R = 21. Based on the past 2005-2008 occultations successfully predicted, recorded and fitted, a linear drift with time in declination with regard to DE418/plu017 ephemerides was determined for Pluto and used in the current predictions. For offset (mas) = A * (t (yr) - 2005.0) + B, we find A = +30.5 ± 4.3 mas yr-1 and B = -31.5 ± 11.3 mas, with standard deviation of 14.4 mas for the offsets. For these past occultations, predictions and follow-up observations were made with the 0.6 m and 1.6 m telescopes at the Laboratório Nacional de Astrofísica/Brazil. Conclusions: Recurrent issues in stellar occultation predictions were addressed and properly overcome: body ephemeris offsets, catalog zero-point position errors and field-of-view size, long-term predictions and stellar proper motions, faint-visual versus bright-infrared stars and star/body astrometric follow-up. In particular, we highlight the usefulness of the obtained astrometric catalog as a reference frame for star/body astrometric follow-up before and after future events involving the Pluto system. Besides, it also furnishes useful photometric information for field stars in the flux calibration of observed light curves. Updates on the ephemeris offsets and candidate star positions (geometric conditions of predictions and finding charts) are made available by the group at http://www.lesia.obspm.fr/perso/bruno-sicardy Tables of predictions for stellar occultations by Pluto, Charon, Nix and Hydra for 2008-2015 and Catalog of star positions for 2008-2015 sky path of Pluto are only available in electronic form at the CDS via anonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or via http://cdsweb.u-strasbg.fr/cgi-bin/qcat?J/A+A/515/A32Observations made through the ESO run 079.A-9202(A), 075.C-0154, 077.C-0283 and 079.C-0345.Also based on observations made at the Laboratório Nacional de Astrofísica (LNA), Itajubá-MG, Brazil.
Vijfhuize, S; Deden, A C; Costerus, S A; Sloots, C E J; Wijnen, R M H
2012-10-01
Congenital diaphragmatic hernia (CDH) is a congenital life-threatening condition requiring surgical repair in the neonatal period. Minimal access surgery (MAS) is gaining ground on the classical open approach by laparotomy or thoracotomy as it minimizes damage to the abdominal or thoracic wall. Using an open review of the literature, we aimed to determine whether MAS is safe and effective in treating CDH. Furthermore, we provide selection criteria for the optimal surgical approach, laid down in a decision algorithm. An online search of MEDLINE was performed (May 2012), followed by a citations search. All study types except case reports describing open and/or MAS repair of Bochdalek CDH were eligible. Primary outcome data, for example, surgical complications and mortality, were recorded, as well as secondary outcome measures, for example, operative time, duration of postoperative ventilation, tolerance of enteral nutrition, and total length of stay (LOS) in hospital. Analysis was performed in accordance with the standards of the Cochrane Handbook for Systematic Reviews of Interventions. We identified 15 relevant studies, 5 of them describing MAS only and 10 comparing MAS to open repair of CDH. Numbers of included patients and selection criteria for MAS varied widely. Most studies have methodological limitations, such as the use of retrospective data or historical control groups. ECMO treatment and patch use were more frequent in the open repair group (both p < 0.0001). Recurrence risk seemed to be increased in the MAS group. The need for conversion in MAS series ranged widely, from 3.4 to 75.0%. The risk of general surgical complications did not vary between groups. Mortality seemed to be less in the MAS group. Operative time seemed to be longer in the MAS group. Duration of postoperative ventilation and total LOS appeared to be reduced in this group and patients returned quicker to enteral nutrition. We demonstrate that MAS for diaphragmatic hernia appears to be safe in terms of complications and mortality. Besides, it is associated with faster postoperative recovery. Growing experience with this technique is expected to lower the recurrence risk and to shorten the operative time. These findings should be interpreted cautiously because of methodological limitations of the studies included. Selection criteria used in various studies are associated with an important risk of selection bias. Nonetheless, these criteria can be used to identify patients who will benefit most from MAS. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Proton assisted recoupling and protein structure determination
NASA Astrophysics Data System (ADS)
de Paëpe, Gaël; Lewandowski, Józef R.; Loquet, Antoine; Böckmann, Anja; Griffin, Robert G.
2008-12-01
We introduce a homonuclear version of third spin assisted recoupling, a second-order mechanism that can be used for polarization transfer between 13C or 15N spins in magic angle spinning (MAS) NMR experiments, particularly at high spinning frequencies employed in contemporary high field MAS experiments. The resulting sequence, which we refer to as proton assisted recoupling (PAR), relies on a cross-term between 1H-13C (or 1H-15N) couplings to mediate zero quantum 13C-13C (or 15N-15N recoupling). In particular, using average Hamiltonian theory we derive an effective Hamiltonian for PAR and show that the transfer is mediated by trilinear terms of the form C1+/-C2-/+HZ for 13C-13C recoupling experiments (or N1+/-N2-/+HZ for 15N-15N). We use analytical and numerical simulations to explain the structure of the PAR optimization maps and to delineate the PAR matching conditions. We also detail the PAR polarization transfer dependence with respect to the local molecular geometry and explain the observed reduction in dipolar truncation. Finally, we demonstrate the utility of PAR in structural studies of proteins with 13C-13C spectra of uniformly 13C, 15N labeled microcrystalline Crh, a 85 amino acid model protein that forms a domain swapped dimer (MW=2×10.4 kDa). The spectra, which were acquired at high MAS frequencies (ωr2π>20 kHz) and magnetic fields (750-900 MHz 1H frequencies) using moderate rf fields, exhibit numerous cross peaks corresponding to long (up to 6-7 A˚) 13C-13C distances which are particularly useful in protein structure determination. Using results from PAR spectra we calculate the structure of the Crh protein.
The PMA Catalogue: 420 million positions and absolute proper motions
NASA Astrophysics Data System (ADS)
Akhmetov, V. S.; Fedorov, P. N.; Velichko, A. B.; Shulga, V. M.
2017-07-01
We present a catalogue that contains about 420 million absolute proper motions of stars. It was derived from the combination of positions from Gaia DR1 and 2MASS, with a mean difference of epochs of about 15 yr. Most of the systematic zonal errors inherent in the 2MASS Catalogue were eliminated before deriving the absolute proper motions. The absolute calibration procedure (zero-pointing of the proper motions) was carried out using about 1.6 million positions of extragalactic sources. The mean formal error of the absolute calibration is less than 0.35 mas yr-1. The derived proper motions cover the whole celestial sphere without gaps for a range of stellar magnitudes from 8 to 21 mag. In the sky areas where the extragalactic sources are invisible (the avoidance zone), a dedicated procedure was used that transforms the relative proper motions into absolute ones. The rms error of proper motions depends on stellar magnitude and ranges from 2-5 mas yr-1 for stars with 10 mag < G < 17 mag to 5-10 mas yr-1 for faint ones. The present catalogue contains the Gaia DR1 positions of stars for the J2015 epoch. The system of the PMA proper motions does not depend on the systematic errors of the 2MASS positions, and in the range from 14 to 21 mag represents an independent realization of a quasi-inertial reference frame in the optical and near-infrared wavelength range. The Catalogue also contains stellar magnitudes taken from the Gaia DR1 and 2MASS catalogues. A comparison of the PMA proper motions of stars with similar data from certain recent catalogues has been undertaken.
NASA Astrophysics Data System (ADS)
Angel, E.; Wellnitz, C.; Goodsitt, M.; DeMarco, J.; Cagnon, C.; Ghatali, M.; Cody, D.; Stevens, D.; McCollough, C.; Primak, A.; McNitt-Gray, M.
2007-03-01
Pregnant women with shortness of breath are increasingly referred for CT Angiography to rule out Pulmonary Embolism (PE). While this exam is typically focused on the lungs, extending scan boundaries and overscan can add to the irradiated volume and have implications on fetal dose. The purpose of this work was to estimate radiation dose to the fetus when various levels of overscan were encountered. Two voxelized models of pregnant patients derived from actual patient anatomy were created based on image data. The models represent an early (< 7 weeks) and late term pregnancy (36 weeks). A previously validated Monte Carlo model of an MDCT scanner was used that takes into account physical details of the scanner. Simulated helical scans used 120 kVp, 4x5 mm beam collimation, pitch 1, and varying beam-off locations (edge of the irradiated volume) were used to represent different protocols plus overscan. Normalized dose (mGy/100mAs) was calculated for each fetus. For the early term and the late term pregnancy models, fetal dose estimates for a standard thoracic PE exam were estimated to be 0.05 and 0.3 mGy/100mAs, respectively, increasing to 9 mGy/100mAs when the beam-off location was extended to encompass the fetus. When performing PE exams to rule out PE in pregnant patients, the beam-off location may have a large effect on fetal dose, especially for late term pregnancies. Careful consideration of ending location of the x-ray beam - and not the end of image data - could result in significant reduction in radiation dose to the fetus.
77 FR 43084 - Multiple Award Schedule (MAS) Program Continuous Open Season-Operational Change
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-23
... Award Schedule (MAS) Program Continuous Open Season- Operational Change AGENCY: Federal Acquisition... proposing this operational change to enhance the performance of and modernize the MAS program in three key program areas: Small business viability, operational efficiency, and cost control. The DBM will realign...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Furuta, Masaki, E-mail: furutam@mail.tagen.tohoku.ac.jp; Okamoto, Satoshi; Kikuchi, Nobuaki
2014-04-07
We have studied the dot size dependence of microwave assisted magnetization switching (MAS) on perpendicular magnetic Co/Pt multilayer dot array. The significant microwave assistance effect has been observed over the entire dot size D ranging from 50 nm to 330 nm examined in the present study. The MAS behavior, however, critically depends on D. The excitation frequency dependence of the switching field is well consistent with the spin wave theory, indicating that the magnetization precession in MAS is in accordance with the well defined eigenmodes depending on the dot diameter. The lowest order spin wave is only excited for D ≤ 100 nm, and thenmore » the MAS effect is well consistent with that of the single macrospin prediction. On the other hand, higher order spin waves are excited for D > 100 nm, giving rise to the significant enhancement of the MAS effect. The dispersion of MAS effect also depends on D and is significantly reduced for the region of D > 100 nm. This significant reduction of the dispersion is attributed to the essential feature of the MAS effect which is insensitive to the local fluctuation of anisotropy field, such as defect, damaged layer, and so on.« less
Mercury Distribution in the Processing of Jatiroto Gold Mine Wonogiri Central Java Indonesia
NASA Astrophysics Data System (ADS)
Fitri Yudiantoro, Dwi; Nurcholis, Muhammad; Sri Sayudi, Dewi; Abdurrachman, Mirzam; Paramita Haty, Intan; Pambudi, Wiryan; Subroborini, Arum
2017-06-01
The research area is one of the Wonogiri gold producer. In this region there are nearly 30 gold processing locations. This area has a steep morphology which is part of Mt. Mas. The work of the gold processing is a part time job besides for the local farmer population. To get the gold bearing rocks, are by digging holes manually around Mt. Mas, while gold processing is carried out in their homes. As a result of these activities, then identified the distribution of mercury in the surrounding settlements. Analytical methods used in this study is the measurement mercury content using Hg meter on altered rocks, soil and using XRF (X-Ray Fluorescence) for plant samples. This results of research shows that there are conducted on mercury contents in the altered rocks, soil and plants showed significant mercury contents in altered rocks, soil and plants. This proves that mercury has polluted the environment surrounding residents, both of people living in the hill down on the lower plain areas. The results of this study are expected to be used as reference to help overcome the pollution of the area.
How Reliable Is the Prediction of Solar Wind Background?
NASA Astrophysics Data System (ADS)
Jian, Lan K.; MacNeice, Peter; Taktakishvili, Aleksandre; Odstrcil, Dusan; Jackson, Bernard; Yu, Hsiu-Shan; Riley, Pete; Sokolov, Igor
2015-04-01
The prediction of solar wind background is a necessary part of space weather forecasting. Multiple coronal and heliospheric models have been installed at the Community Coordinated Modeling Center (CCMC) to produce the solar wind, including the Wang-Sheely-Arge (WSA)-Enlil model, MHD-Around-a-Sphere (MAS)-Enlil model, Space Weather Modeling Framework (SWMF), and heliospheric tomography using interplanetary scintillation (IPS) data. By comparing the modeling results with the OMNI data over 7 Carrington rotations in 2007, we have conducted a third-party validation of these models for the near-Earth solar wind. This work will help the models get ready for the transition from research to operation. Besides visual comparison, we have quantitatively assessed the models’ capabilities in reproducing the time series and statistics of solar wind parameters. Using improved algorithms, we have identified magnetic field sector boundaries (SBs) and slow-to-fast stream interaction regions (SIRs) as focused structures. The success rate of capturing them and the time offset vary largely with models. For this period, the 2014 version of MAS-Enlil model works best for SBs, and the heliospheric tomography works best for SIRs. General strengths and weaknesses for each model are identified to provide an unbiased reference to model developers and users.
Tsakiris, Ioannis; Torocsik, Daniel; Gyongyosi, Adrienn; Dozsa, Aniko; Szatmari, Istvan; Szanto, Attila; Soos, Gyorgyike; Nemes, Zoltan; Igali, Laszlo; Marton, Ildiko; Takats, Zoltan; Nagy, Laszlo; Dezso, Balazs
2012-01-01
Granulomatous inflammations, characterized by the presence of activated macrophages (MAs) forming epithelioid cell (EPC) clusters, are usually easy to recognize. However, in ambiguous cases the use of a MA marker that expresses selectively in EPCs may be needed. Here, we report that carboxypeptidase-M (CPM), a MA-differentiation marker, is preferentially induced in EPCs of all granuloma types studied, but not in resting MAs. As CPM is not expressed constitutively in MAs, this allows utilization of CPM-immunohistochemistry in diagnostics of minute granuloma detection when dense non-granulomatous MAs are also present. Despite this rule, hardly any detectable CPM was found in advanced/active tubercle caseous disease, albeit in early tuberculosis granuloma, MAs still expressed CPM. Indeed, in vitro both the CPM-protein and -mRNA became downregulated when MAs were infected with live mycobacteria. In vitro, MA-CPM transcript is neither induced remarkably by interferon-γ, known to cause classical MA activation, nor by IL-4, an alternative MA activator. Instead, CPM is selectively expressed in lipid-laden MAs, including the foam cells of atherosclerotic plaques, xanthomatous lesions and lipid pneumonias. By using serum, rich in lipids, and low-density lipoprotein (LDL) or VLDL, CPM upregulation could be reproduced in vitro in monocyte-derived MAs both at transcriptional and protein levels, and the increase is repressed under lipid-depleted conditions. The microarray analyses support the notion that CPM induction correlates with a robust progressive increase in CPM gene expression during monocyte to MA maturation and dendritic cell (DC) differentiation mediated by granulocyte–MA-colony-stimulating factor+IL-4. M-CSF alone also induced CPM. These results collectively indicate that CPM upregulation in MAs is preferentially associated with increased lipid uptake, and exposure to CSF, features of EPCs, also. Therefore, CPM-immunohistochemistry is useful for granuloma and foam MA detections in tissue sections. Furthermore, the present data offer CPM for the first time to be a novel marker and cellular player in lipid uptake and/or metabolism of MAs by promoting foam cell formation. PMID:22157720
Prencipe, Giusi; Caiello, Ivan; Pascarella, Antonia; Grom, Alexei A; Bracaglia, Claudia; Chatel, Laurence; Ferlin, Walter G; Marasco, Emiliano; Strippoli, Raffaele; de Min, Cristina; De Benedetti, Fabrizio
2018-04-01
The pathogenesis of macrophage activation syndrome (MAS) is not clearly understood: a large body of evidence supports the involvement of mechanisms similar to those implicated in the setting of primary hemophagocytic lymphohistiocytosis. We sought to investigate the pathogenic role of IFN-γ and the therapeutic efficacy of IFN-γ neutralization in an animal model of MAS. We used an MAS model established in mice transgenic for human IL-6 (IL-6TG mice) challenged with LPS (MAS mice). Levels of IFN-γ and IFN-γ-inducible chemokines were evaluated by using real-time PCR in the liver and spleen and by means of ELISA in plasma. IFN-γ neutralization was achieved by using the anti-IFN-γ antibody XMG1.2 in vivo. Mice with MAS showed a significant upregulation of the IFN-γ pathway, as demonstrated by increased mRNA levels of Ifng and higher levels of phospho-signal transducer and activator of transcription 1 in the liver and spleen and increased expression of the IFN-γ-inducible chemokines Cxcl9 and Cxcl10 in the liver and spleen, as well as in plasma. A marked increase in Il12a and Il12b expression was also found in livers and spleens of mice with MAS. In addition, mice with MAS had a significant increase in numbers of liver CD68 + macrophages. Mice with MAS treated with an anti-IFN-γ antibody showed a significant improvement in survival and body weight recovery associated with a significant amelioration of ferritin, fibrinogen, and alanine aminotransferase levels. In mice with MAS, treatment with the anti-IFN-γ antibody significantly decreased circulating levels of CXCL9, CXCL10, and downstream proinflammatory cytokines. The decrease in CXCL9 and CXCL10 levels paralleled the decrease in serum levels of proinflammatory cytokines and ferritin. These results provide evidence for a pathogenic role of IFN-γ in the setting of MAS. Copyright © 2017 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
A Distributed Intelligent E-Learning System
ERIC Educational Resources Information Center
Kristensen, Terje
2016-01-01
An E-learning system based on a multi-agent (MAS) architecture combined with the Dynamic Content Manager (DCM) model of E-learning, is presented. We discuss the benefits of using such a multi-agent architecture. Finally, the MAS architecture is compared with a pure service-oriented architecture (SOA). This MAS architecture may also be used within…
McCune-Albright syndrome: growth hormone and prolactin hypersecretion.
Christoforidis, Athanasios; Maniadaki, Ilianna; Stanhope, Richard
2006-05-01
McCune-Albright syndrome (MAS) has a special interest for endocrinologists as its pathogenesis results in hypersecretion of hormones in peripheral endocrine tissues. This can be expressed as precocious puberty, mainly in girls, primary hyperthyroidism, growth hormone (GH) and/or prolactin excess, hyperparathyroidism and hypercortisolism. The incidence of GH excess among patients with MAS has been assessed as up to 21%. The pathogenesis of GH hypersecretion in MAS is not completely understood, whereas it seems to be different from the aetiology of acromegaly/gigantism in non-MAS patients. The clinical expression of GH excess can be masked because of precocious puberty or craniofacial fibrous dysplasia, indicating the necessity for screening. Medical treatment is usually the only option in MAS patients with GH excess, as transsphenoidal surgery is usually restricted due to massive thickening of the skull base, whereas radiotherapy is contraindicated due to probable higher predisposition to sarcomatous transformation. The use of bromocriptine, cabergoline and octreotide, or the combination of these, has shown variable results, whereas pegvisomant, a GH receptor antagonist, is a new promising option, although not yet used in patients with MAS.
BOREAS Level-1B MAS Imagery At-sensor Radiance, Relative X and Y Coordinates
NASA Technical Reports Server (NTRS)
Strub, Richard; Strub, Richard; Newcomer, Jeffrey A.; Ungar, Stephen
2000-01-01
For BOReal Ecosystem-Atmosphere Study (BOREAS), the MODIS Airborne Simulator (MAS) images, along with the other remotely sensed data, were collected to provide spatially extensive information over the primary study areas. This information includes detailed land cover and biophysical parameter maps such as fraction of Photosynthetically Active Radiation (fPAR) and Leaf Area Index (LAI). Collection of the MAS images occurred over the study areas during the 1994 field campaigns. The level-1b MAS data cover the dates of 21-Jul-1994, 24-Jul-1994, 04-Aug-1994, and 08-Aug-1994. The data are not geographically/geometrically corrected; however, files of relative X and Y coordinates for each image pixel were derived by using the C-130 INS data in a MAS scan model. The data are provided in binary image format files.
Oral Appliance Treatment Response and Polysomnographic Phenotypes of Obstructive Sleep Apnea
Sutherland, Kate; Takaya, Hisashi; Qian, Jin; Petocz, Peter; Ng, Andrew T.; Cistulli, Peter A.
2015-01-01
Study Objectives: Mandibular advancement splints (MAS) are an effective treatment for obstructive sleep apnea (OSA); however, therapeutic response is variable. Younger age, female gender, less obesity, and milder and supine-dependent OSA have variably been associated with treatment success in relatively small samples. Our objective was to utilize a large cohort of MAS treated patients (1) to compare efficacy across patients with different phenotypes of OSA and (2) to assess demographic, anthropometric, and polysomnography variables as treatment response predictors. Methods: Retrospective analysis of MAS-treated patients participating in clinical trials in sleep centers in Sydney, Australia between years 2000–2013. All studies used equivalent customized two-piece MAS devices and treatment protocols. Treatment response was defined as (1) apnea-hypopnea index (AHI) < 5/h, (2) AHI < 10/h and ≥ 50% reduction, and (3) ≥ 50% AHI reduction. Results: A total of 425 patients (109 female) were included (age 51.2 ± 10.9 years, BMI 29.2 ± 5.0 kg/m2). MAS reduced AHI by 50.3% ± 50.7% across the group. Supine-predominant OSA patients had lower treatment response rates than non-positional OSA (e.g., 36% vs. 59% for AHI < 10/h). REM-predominant OSA showed a lower response rate than either NREM or non-stage dependent OSA. In prediction modelling, age, baseline AHI, and anthropometric variables were predictive of MAS treatment outcome but not OSA phenotype. Gender was not associated with treatment outcome. Conclusions: Lower MAS treatment response rates were observed in supine and REM sleep. In a large sample, we confirm that demographic, anthropometric, and polysomnographic data only weakly inform about MAS efficacy, supporting the need for alternative objective prediction methods to reliably select patients for MAS treatment. Citation: Sutherland K, Takaya H, Qian J, Petocz P, Ng AT, Cistulli PA. Oral appliance treatment response and polysomnographic phenotypes of obstructive sleep apnea. J Clin Sleep Med 2015;11(8):861–868. PMID:25845897
Effect of high-pitch dual-source CT to compensate motion artifacts: a phantom study.
Farshad-Amacker, Nadja A; Alkadhi, Hatem; Leschka, Sebastian; Frauenfelder, Thomas
2013-10-01
To evaluate the potential of high-pitch, dual-source computed tomography (DSCT) for compensation of motion artifacts. Motion artifacts were created using a moving chest/cardiac phantom with integrated stents at different velocities (from 0 to 4-6 cm/s) parallel (z direction), transverse (x direction), and diagonal (x and z direction combined) to the scanning direction using standard-pitch (SP) (pitch = 1) and high-pitch (HP) (pitch = 3.2) 128-detector DSCT (Siemens, Healthcare, Forchheim, Germany). The scanning parameters were (SP/HP): tube voltage, 120 kV/120 kV; effective tube current time product, 300 mAs/500 mAs; and a pitch of 1/3.2. Motion artifacts were analyzed in terms of subjective image quality and object distortion. Image quality was rated by two blinded, independent observers using a 4-point scoring system (1, excellent; 2, good with minor object distortion or blurring; 3, diagnostically partially not acceptable; and 4, diagnostically not acceptable image quality). Object distortion was assessed by the measured changes of the object's outer diameter (x) and length (z) and a corresponding calculated distortion vector (d) (d = √(x(2) + z(2))). The interobserver agreement was excellent (k = 0.91). Image quality using SP was diagnostically not acceptable with any motion in x direction (scores 3 and 4), in contrast to HP DSCT where it remained diagnostic up to 2 cm/s (scores 1 and 2). For motion in the z direction only, image quality remained diagnostic for SP and HP DSCT (scores 1 and 2). Changes of the object's diameter (x), length (z), and distortion vectors (d) were significantly greater with SP (overall: x = 1.9 cm ± 1.7 cm, z = 0.6 cm ± 0.8 cm, and d = 1.4 cm ± 1.5 cm) compared to HP DSCT (overall: x = 0.1 cm ± 0.1 cm, z = 0.0 cm ± 0.1 cm, and d = 0.1 cm ± 0.1 cm; each P < .05). High-pitch DSCT significantly decreases motion artifacts in various directions and improves image quality. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.
MAS NMR of HIV-1 protein assemblies
NASA Astrophysics Data System (ADS)
Suiter, Christopher L.; Quinn, Caitlin M.; Lu, Manman; Hou, Guangjin; Zhang, Huilan; Polenova, Tatyana
2015-04-01
The negative global impact of the AIDS pandemic is well known. In this perspective article, the utility of magic angle spinning (MAS) NMR spectroscopy to answer pressing questions related to the structure and dynamics of HIV-1 protein assemblies is examined. In recent years, MAS NMR has undergone major technological developments enabling studies of large viral assemblies. We discuss some of these evolving methods and technologies and provide a perspective on the current state of MAS NMR as applied to the investigations into structure and dynamics of HIV-1 assemblies of CA capsid protein and of Gag maturation intermediates.
The megaaortic syndrome: Progression of ascending aortic aneurysm or a disease of distinct origin?
Baranyi, Ulrike; Stern, Christian; Winter, Birgitta; Türkcan, Adrian; Scharinger, Bernhard; Stelzmüller, Marie-Elisabeth; Aschacher, Thomas; Andreas, Martin; Ehrlich, Marek; Laufer, Günther; Bernhard, David; Messner, Barbara
2017-01-15
Thoracic aortic aneurysm (TAA) is an often asymptomatic disease with fatal outcome, such as dissection or rupture. The megaaortic syndrome (MAS) is an extensive dilatation of the whole aorta with low incidence but high lethal outcome with unknown pathophysiology so far. We compared aortic tissue of patients with sporadic TAAs and MAS of the ascending aorta with non-aneurysmal control tissues. Specimens of MAS patients showed a significantly reduced thickness of the media but an increased thickness of the intima compared to control tissue and TAAs with moderate dilatation. Advanced media degeneration however was detectable in both, TAAs with enhanced luminal diameter and MAS specimens, accompanied by reduced medial smooth muscle cell-density. Further specimens of MAS were characterized by massive atherosclerotic lesions in contrast to specimens of sporadic TAA patients. Infiltrations of macrophages in atherosclerotic lesions but also in the media adjacent to the adventitia were significantly elevated in tissue of TAAs with dilatation ≤6cm. Of note, atherosclerotic plaque-associated macrophages as well as those in the external media produce huge amounts of MMP-9 which is possibly involved in media degeneration and tissue destruction. Taken together these results demonstrate that the pathology of MAS shows similarities with that of TAAs but pathological differences in the ascending aorta, suggesting that MAS might be a disease of different origin. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Multinuclear (27Al, 29Si, 47,49Ti) solid-state NMR of titanium substituted zeolite USY.
Ganapathy, S; Gore, K U; Kumar, Rajiv; Amoureux, Jean-Paul
2003-01-01
Multinuclear solid-state NMR spectroscopy, employing 29Si MAS,27Al MAS/3Q-MAS and (47,49)Ti wide-line experiments, has been used for the structural characterization of titanium substituted ultra-stable zeolite Y (Ti-USY). 27Al MAS experiments show the presence of aluminum in four (Al(IV)), five (Al(V)), and six (Al(VI)) coordination, whereas the multiplicity within Al(IV) and Al(VI) is revealed by 27Al 3Q-MAS experiments. Two different tetrahedral and octahedral Al environments are resolved and their isotropic chemical shifts (delta(CS)) and second-order quadrupole interaction parameters (P(Q)) have been determined by a graphical analysis of the 3Q-MAS spectra. The emergence of signal with higher intensity at -101 ppm in the 29Si MAS spectrum of Ti-USY samples indicates the possible occurrence of Q4(3Si,1Ti) type silicon environments due to titanium substitution in the faujasite framework. High-field (11.74T) operation, using a probehead specially designed to handle a large sample volume, has enabled the acquisition of 47,49Ti static spectra and identification of the titanium environment in the zeolite. The chemical shielding and electric field gradient tensors for the titanium environment in the zeolite have been determined by a computer simulation of the quadrupolar broadened static 47,49Ti NMR spectra.
Contrast Enhancement of the Right Ventricle during Coronary CT Angiography--Is It Necessary?
Kok, Madeleine; Kietselaer, Bas L J H; Mihl, Casper; Altintas, Sibel; Nijssen, Estelle C; Wildberger, Joachim E; Das, Marco
2015-01-01
It is unclear if prolonged contrast media injection, to improve right ventricular visualization during coronary CT angiography, leads to increased detection of right ventricle pathology. The purpose of this study was to evaluate right ventricle enhancement and subsequent detection of right ventricle disease during coronary CT angiography. 472 consecutive patients referred for screening coronary CT angiography were retrospectively evaluated. Every patient underwent multidetector-row CT of the coronary arteries: 128x 0.6mm coll., 100-120kV, rot. time 0.28s, ref. mAs 350 and received an individualized (P3T) contrast bolus injection of iodinated contrast medium (300 mgI/ml). Patient data were analyzed to assess right ventricle enhancement (HU) and right ventricle pathology. Image quality was defined good when right ventricle enhancement >200HU, moderate when 140-200HU and poor when <140HU. Good image quality was found in 372 patients, moderate in 80 patients and poor in 20 patients. Mean enhancement of the right ventricle cavity was 268HU±102. Patients received an average bolus of 108±24 ml at an average peak flow rate of 6.1±2.2 ml/s. In only three out of 472 patients (0.63%) pathology of the right ventricle was found (dilatation) No other right ventricle pathology was detected. Right ventricle pathology was detected in three out of 472 patients; the dilatation observed in these three cases may have been picked up even without dedicated enhancement of the right ventricle. Based on our findings, right ventricle enhancement can be omitted during screening coronary CT angiography.
ERIC Educational Resources Information Center
Koritsas, S.; Iacono, T.
2013-01-01
Background: The Motivation Assessment Scale (MAS) and the Questions About Behavioral Function (QABF) are frequently used to assess the learned function of challenging behaviour in people with intellectual disability (ID). The aim was to explore and compare the psychometric properties of the MAS and the QABF. Method: Seventy adults with ID and…
Warejko, Jillian K; Schueler, Markus; Vivante, Asaf; Tan, Weizhen; Daga, Ankana; Lawson, Jennifer A; Braun, Daniela A; Shril, Shirlee; Amann, Kassaundra; Somers, Michael J G; Rodig, Nancy M; Baum, Michelle A; Daouk, Ghaleb; Traum, Avram Z; Kim, Heung Bae; Vakili, Khashayar; Porras, Diego; Lock, James; Rivkin, Michael J; Chaudry, Gulraiz; Smoot, Leslie B; Singh, Michael N; Smith, Edward R; Mane, Shrikant M; Lifton, Richard P; Stein, Deborah R; Ferguson, Michael A; Hildebrandt, Friedhelm
2018-04-01
Midaortic syndrome (MAS) is a rare cause of severe childhood hypertension characterized by narrowing of the abdominal aorta in children and is associated with extensive vascular disease. It may occur as part of a genetic syndrome, such as neurofibromatosis, or as consequence of a pathological inflammatory disease. However, most cases are considered idiopathic. We hypothesized that in a high percentage of these patients, a monogenic cause of disease may be detected by evaluating whole exome sequencing data for mutations in 1 of 38 candidate genes previously described to cause vasculopathy. We studied a cohort of 36 individuals from 35 different families with MAS by exome sequencing. In 15 of 35 families (42.9%), we detected likely causal dominant mutations. In 15 of 35 (42.9%) families with MAS, whole exome sequencing revealed a mutation in one of the genes previously associated with vascular disease ( NF1 , JAG1 , ELN , GATA6 , and RNF213 ). Ten of the 15 mutations have not previously been reported. This is the first report of ELN , RNF213 , or GATA6 mutations in individuals with MAS. Mutations were detected in NF1 (6/15 families), JAG1 (4/15 families), ELN (3/15 families), and one family each for GATA6 and RNF213 Eight individuals had syndromic disease and 7 individuals had isolated MAS. Whole exome sequencing can provide conclusive molecular genetic diagnosis in a high fraction of individuals with syndromic or isolated MAS. Establishing an etiologic diagnosis may reveal genotype/phenotype correlations for MAS in the future and should, therefore, be performed routinely in MAS. © 2018 American Heart Association, Inc.
Bislev, Lise Sofie; Cashman, Kevin D.; Eiríksdottir, Gudny; Gaksch, Martin; Grübler, Martin; Grimnes, Guri; Gudnason, Vilmundur; Lips, Paul; Pilz, Stefan; van Schoor, Natasja M.; Kiely, Mairead; Jorde, Rolf
2017-01-01
Background A large number of observational studies have reported harmful effects of low 25-hydroxyvitamin D (25OHD) levels on non-skeletal outcomes. We performed a systematic quantitative review on characteristics of randomized clinical trials (RCTs) included in meta-analyses (MAs) on non-skeletal effects of vitamin D supplementation. Methods and findings We identified systematic reviews (SR) reporting summary data in terms of MAs of RCTs on selected non-skeletal outcomes. For each outcome, we summarized the results from available SRs and scrutinized included RCTs for a number of predefined characteristics. We identified 54 SRs including data from 210 RCTs. Most MAs as well as the individual RCTs reported null-findings on risk of cardiovascular diseases, type 2 diabetes, weight-loss, and malignant diseases. Beneficial effects of vitamin D supplementation was reported in 1 of 4 MAs on depression, 2 of 9 MAs on blood pressure, 3 of 7 MAs on respiratory tract infections, and 8 of 12 MAs on mortality. Most RCTs have primarily been performed to determine skeletal outcomes, whereas non-skeletal effects have been assessed as secondary outcomes. Only one-third of the RCTs had low level of 25OHD as a criterion for inclusion and a mean baseline 25OHD level below 50 nmol/L was only present in less than half of the analyses. Conclusions Published RCTs have mostly been performed in populations without low 25OHD levels. The fact that most MAs on results from RCTs did not show a beneficial effect does not disprove the hypothesis suggested by observational findings on adverse health outcomes of low 25OHD levels. PMID:28686645
[Quality assurance in diagnostic radiology using an automated system. Experience and results].
Princivalli, M; Stea, L; Ordóñez, P L; Bussoli, L; Marchetti, C
1995-05-01
The authors report their personal experience with the use of an integrated quality control system in the radiology department. The system we used was the RTI DIGI-X Plus, a Swedish-made product, allowing a wide range of parameters to be measured on diagnostic X-ray units for general radiography, mammography and fluoroscopy. Data can be retrieved with a minimum number of measurements. The "oRTIgo" software improves the quality assurance system and ensures document compliance with international recommendations. The equipment consists of a detector unit, a processor and a display unit. The detector consists of a rotating holder with 12 combinations of metal filters of various thickness mounted in front of two photo-diodes covered with identical X-ray intensifying gadoliniumoxysulfide screens. This unit is connected to a data acquisition system controlled by a microcomputer. Peak tube voltage and total tube filtration are derived from the ratio of detector signals. The relationship between this ratio and the measured quantity is determined by a calibration procedure. Furthermore, exposure time "mAs" value, "mAs" linearity and exposure (or kerma in air) can be measured. Digital storage can be performed and input signals displayed. A serial interface is used to communicate with a PC for QC management purposes. An error propagation model is used to determine the inaccuracy of peak tube voltage measurements. With the DIGI-X Plus system, measurements can be carried out in a shorter time and the stored data reprocessed later on. After QA testing on 20 X-ray units in the radiology department, in vivo doses were measured using a TLD Harshaw 100 on 46 randomly selected patients undergoing chest examinations. The results are reported and analyzed following the NRPB protocol and show high agreement with the recommended values.
Papadakis, Antonios E; Perisinakis, Kostas; Damilakis, John
2014-10-01
To study the effect of patient size, body region and modulation strength on tube current and image quality on CT examinations that use automatic tube current modulation (ATCM). Ten physical anthropomorphic phantoms that simulate an individual as neonate, 1-, 5-, 10-year-old and adult at various body habitus were employed. CT acquisition of head, neck, thorax and abdomen/pelvis was performed with ATCM activated at weak, average and strong modulation strength. The mean modulated mAs (mAsmod) values were recorded. Image noise was measured at selected anatomical sites. The mAsmod recorded for neonate compared to 10-year-old increased by 30 %, 14 %, 6 % and 53 % for head, neck, thorax and abdomen/pelvis, respectively, (P < 0.05). The mAsmod was lower than the preselected mAs with the exception of the 10-year-old phantom. In paediatric and adult phantoms, the mAsmod ranged from 44 and 53 for weak to 117 and 93 for strong modulation strength, respectively. At the same exposure parameters image noise increased with body size (P < 0.05). The ATCM system studied here may affect dose differently for different patient habitus. Dose may decrease for overweight adults but increase for children older than 5 years old. Care should be taken when implementing ATCM protocols to ensure that image quality is maintained. • ATCM efficiency is related to the size of the patient's body. • ATCM should be activated without caution in overweight adult individuals. • ATCM may increase radiation dose in children older than 5 years old. • ATCM efficiency depends on the protocol selected for a specific anatomical region. • Modulation strength may be appropriately tuned to enhance ATCM efficiency.
Miura, Yohei; Ichikawa, Katsuhiro; Fujimura, Ichiro; Hara, Takanori; Hoshino, Takashi; Niwa, Shinji; Funahashi, Masao
2018-03-01
The 320-detector row computed tomography (CT) system, i.e., the area detector CT (ADCT), can perform helical scanning with detector configurations of 4-, 16-, 32-, 64-, 80-, 100-, and 160-detector rows for routine CT examinations. This phantom study aimed to compare the quality of images obtained using helical scan mode with different detector configurations. The image quality was measured using modulation transfer function (MTF) and noise power spectrum (NPS). The system performance function (SP), based on the pre-whitening theorem, was calculated as MTF 2 /NPS, and compared between configurations. Five detector configurations, i.e., 0.5 × 16 mm (16 row), 0.5 × 64 mm (64 row), 0.5 × 80 mm (80 row), 0.5 × 100 mm (100 row), and 0.5 × 160 mm (160 row), were compared using a constant volume CT dose index (CTDI vol ) of 25 mGy, simulating the scan of an adult abdomen, and with a constant effective mAs value. The MTF was measured using the wire method, and the NPS was measured from images of a 20-cm diameter phantom with uniform content. The SP of 80-row configuration was the best, for the constant CTDI vol , followed by the 64-, 160-, 16-, and 100-row configurations. The decrease in the rate of the 100- and 160-row configurations from the 80-row configuration was approximately 30%. For the constant effective mAs, the SPs of the 100-row and 160-row configurations were significantly lower, compared with the other three detector configurations. The 80- and 64-row configurations were adequate in cases that required dose efficiency rather than scan speed.
Radiation dose reduction for CT lung cancer screening using ASIR and MBIR: a phantom study
Mathieu, Kelsey B.; Ai, Hua; Fox, Patricia S.; Godoy, Myrna Cobos Barco; Munden, Reginald F.; de Groot, Patricia M.
2014-01-01
The purpose of this study was to reduce the radiation dosage associated with computed tomography (CT) lung cancer screening while maintaining overall diagnostic image quality and definition of ground‐glass opacities (GGOs). A lung screening phantom and a multipurpose chest phantom were used to quantitatively assess the performance of two iterative image reconstruction algorithms (adaptive statistical iterative reconstruction (ASIR) and model‐based iterative reconstruction (MBIR)) used in conjunction with reduced tube currents relative to a standard clinical lung cancer screening protocol (51 effective mAs (3.9 mGy) and filtered back‐projection (FBP) reconstruction). To further assess the algorithms' performances, qualitative image analysis was conducted (in the form of a reader study) using the multipurpose chest phantom, which was implanted with GGOs of two densities. Our quantitative image analysis indicated that tube current, and thus radiation dose, could be reduced by 40% or 80% from ASIR or MBIR, respectively, compared with conventional FBP, while maintaining similar image noise magnitude and contrast‐to‐noise ratio. The qualitative portion of our study, which assessed reader preference, yielded similar results, indicating that dose could be reduced by 60% (to 20 effective mAs (1.6 mGy)) with either ASIR or MBIR, while maintaining GGO definition. Additionally, the readers' preferences (as indicated by their ratings) regarding overall image quality were equal or better (for a given dose) when using ASIR or MBIR, compared with FBP. In conclusion, combining ASIR or MBIR with reduced tube current may allow for lower doses while maintaining overall diagnostic image quality, as well as GGO definition, during CT lung cancer screening. PACS numbers: 87.57.Q‐, 87.57.nf PMID:24710436
NASA Technical Reports Server (NTRS)
Yang, Genevie Velarde; Mohr, David; Kirby, Charles E.
2008-01-01
To keep Cassini on its complex trajectory, more than 200 orbit trim maneuvers (OTMs) have been planned from July 2004 to July 2010. With only a few days between many of these OTMs, the operations process of planning and executing the necessary commands had to be automated. The resulting Maneuver Automation Software (MAS) process minimizes the workforce required for, and maximizes the efficiency of, the maneuver design and uplink activities. The MAS process is a well-organized and logically constructed interface between Cassini's Navigation (NAV), Spacecraft Operations (SCO), and Ground Software teams. Upon delivery of an orbit determination (OD) from NAV, the MAS process can generate a maneuver design and all related uplink and verification products within 30 minutes. To date, all 112 OTMs executed by the Cassini spacecraft have been successful. MAS was even used to successfully design and execute a maneuver while the spacecraft was in safe mode.
Pernomian, Larissa; Pernomian, Laena; Gomes, Mayara S; da Silva, Carlos H T P
2015-12-15
The interplay between angiotensin AT1 receptors and MAS receptors relies on several inward regulatory mechanisms from renin-angiotensin system (RAS) including the functional crosstalk between angiotensin II and angiotensin-(1-7), the competitive AT1 antagonism exhibited by angiotensin-(1-7), the antagonist feature assigned to AT1/MAS heterodimerization on AT1 signaling and the AT1-mediated downregulation of angiotensin-converting enzyme 2 (ACE2). Recently, such interplay has acquired an important significance to RAS Pharmacology since a few studies have supporting strong evidences that MAS receptors mediate the effects elicited by AT1 antagonists. The present Perspective provides an overview of the regulatory mechanisms involving AT1 and MAS receptors, their significance to RAS Pharmacology and the future directions on the interplay between angiotensin receptors. Copyright © 2015 Elsevier B.V. All rights reserved.
Advances in the Management of Meconium Aspiration Syndrome
Swarnam, Kamala; Soraisham, Amuchou S.; Sivanandan, Sindhu
2012-01-01
Meconium aspiration syndrome (MAS) is a common cause of severe respiratory distress in term infants, with an associated highly variable morbidity and mortality. MAS results from aspiration of meconium during intrauterine gasping or during the first few breaths. The pathophysiology of MAS is multifactorial and includes acute airway obstruction, surfactant dysfunction or inactivation, chemical pneumonitis with release of vasoconstrictive and inflammatory mediators, and persistent pulmonary hypertension of newborn (PPHN). This disorder can be life threatening, often complicated by respiratory failure, pulmonary air leaks, and PPHN. Approaches to the prevention of MAS have changed over time with collaboration between obstetricians and pediatricians forming the foundations for care. The use of surfactant and inhaled nitric oxide (iNO) has led to the decreased mortality and the need for extracorporeal membrane oxygenation (ECMO) use. In this paper, we review the current understanding of the pathophysiology and management of MAS. PMID:22164183
BOREAS Level-2 MAS Surface Reflectance and Temperature Images in BSQ Format
NASA Technical Reports Server (NTRS)
Hall, Forrest G. (Editor); Newcomer, Jeffrey (Editor); Lobitz, Brad; Spanner, Michael; Strub, Richard; Lobitz, Brad
2000-01-01
The BOReal Ecosystem-Atmosphere Study (BOREAS) Staff Science Aircraft Data Acquisition Program focused on providing the research teams with the remotely sensed aircraft data products they needed to compare and spatially extend point results. The MODIS Airborne Simulator (MAS) images, along with other remotely sensed data, were collected to provide spatially extensive information over the primary study areas. This information includes biophysical parameter maps such as surface reflectance and temperature. Collection of the MAS images occurred over the study areas during the 1994 field campaigns. The level-2 MAS data cover the dates of 21-Jul-1994, 24-Jul-1994, 04-Aug-1994, and 08-Aug-1994. The data are not geographically/geometrically corrected; however, files of relative X and Y coordinates for each image pixel were derived by using the C130 navigation data in a MAS scan model. The data are provided in binary image format files.
Mandal, Abhishek; Boatz, Jennifer C.; Wheeler, Travis; van der Wel, Patrick C. A.
2017-01-01
A number of recent advances in the field of magic-angle-spinning (MAS) solid-state NMR have enabled its application to a range of biological systems of ever increasing complexity. To retain biological relevance, these samples are increasingly studied in a hydrated state. At the same time, experimental feasibility requires the sample preparation process to attain a high sample concentration within the final MAS rotor. We discuss these considerations, and how they have led to a number of different approaches to MAS NMR sample preparation. We describe our experience of how custom-made (or commercially available) ultracentrifugal devices can facilitate a simple, fast and reliable sample preparation process. A number of groups have since adopted such tools, in some cases to prepare samples for sedimentation-style MAS NMR experiments. Here we argue for a more widespread adoption of their use for routine MAS NMR sample preparation. PMID:28229262
Concise CIO based precession-nutation formulations
NASA Astrophysics Data System (ADS)
Capitaine, N.; Wallace, P. T.
2008-01-01
Context: The IAU 2000/2006 precession-nutation models have precision goals measured in microarcseconds. To reach this level of performance has required series containing terms at over 1300 frequencies and involving several thousand amplitude coefficients. There are many astronomical applications for which such precision is not required and the associated heavy computations are wasteful. This justifies developing smaller models that achieve adequate precision with greatly reduced computing costs. Aims: We discuss strategies for developing simplified IAU 2000/2006 precession-nutation procedures that offer a range of compromises between accuracy and computing costs. Methods: The chain of transformations linking celestial and terrestrial coordinates comprises frame bias, precession-nutation, Earth rotation and polar motion. We address the bias and precession-nutation (NPB) portion of the chain, linking the Geocentric Celestial Reference System (GCRS) with the Celestial Intermediate Reference System (CIRS), the latter based on the Celestial Intermediate Pole (CIP) and Celestial Intermediate Origin (CIO). Starting from direct series that deliver the CIP coordinates X,Y and (via the quantity s + XY/2) the CIO locator s, we look at the opportunities for simplification. Results: The biggest reductions come from truncating the series, but some additional gains can be made in the areas of the matrix formulation, the expressions for the nutation arguments and by subsuming long period effects into the bias quantities. Three example models are demonstrated that approximate the IAU 2000/2006 CIP to accuracies of 1 mas, 16 mas and 0.4 arcsec throughout 1995-2050 but with computation costs reduced by 1, 2 and 3 orders of magnitude compared with the full model. Appendices A to G are only available in electronic form at http://www.aanda.org
Krawczyk-Coda, Magdalena; Stanisz, Ewa
2017-11-01
This work presents ultrasound-assisted dispersive micro solid phase extraction (USA DMSPE) for preconcentration of fluorine (F) in water and herb samples. TiO 2 nanoparticles (NPs) were used as an adsorbent. The determination with slurry sampling was performed via molecular absorption of calcium monofluoride (CaF) at 606.440 nm using a high-resolution continuum source electrothermal absorption spectrometry (HR-CS ET MAS). Several factors influencing the efficiency of the preconcentration technique, such as the amount of TiO 2 , pH of sample solution, ultrasonication and centrifugation time and TiO 2 slurry solution preparation before injection to HR-CS ET MAS, were investigated in detail. The conditions of detection step (wavelength, calcium amount, pyrolysis and molecule-forming temperatures) were also studied. After extraction, adsorbent with the analyte was mixed with 200 μL of H 2 O to prepare a slurry solution. The concentration limit of detection was 0.13 ng mL -1 . The achieved preconcentration factor was 7. The relative standard deviations (RSDs, %) for F in real samples were 3-15%. The accuracy of this method was evaluated by analyses of certified reference materials after spiking: INCT-MPH-2 (Mixed Polish Herbs), INCT-SBF-4 (Soya Bean Flour), ERM-CAO11b (Hard Drinking Water) and TMDA-54.5 (Lake Ontario Water). The measured F contents in reference materials were in satisfactory agreement with the added amounts, and the recoveries were found to be 97-109%. Under the developed extraction conditions, the proposed method has been successfully applied for the determination of F in real water samples (lake, sea, tap water) and herbs.
Multi-Agent Architecture with Support to Quality of Service and Quality of Control
NASA Astrophysics Data System (ADS)
Poza-Luján, Jose-Luis; Posadas-Yagüe, Juan-Luis; Simó-Ten, Jose-Enrique
Multi Agent Systems (MAS) are one of the most suitable frameworks for the implementation of intelligent distributed control system. Agents provide suitable flexibility to give support to implied heterogeneity in cyber-physical systems. Quality of Service (QoS) and Quality of Control (QoC) parameters are commonly utilized to evaluate the efficiency of the communications and the control loop. Agents can use the quality measures to take a wide range of decisions, like suitable placement on the control node or to change the workload to save energy. This article describes the architecture of a multi agent system that provides support to QoS and QoC parameters to optimize de system. The architecture uses a Publish-Subscriber model, based on Data Distribution Service (DDS) to send the control messages. Due to the nature of the Publish-Subscribe model, the architecture is suitable to implement event-based control (EBC) systems. The architecture has been called FSACtrl.
Song, Eun-Hye; Kim, Hyun-Ju; Jeong, Jaesik; Chung, Hyun-Jung; Kim, Han-Yong; Bang, Eunjung; Hong, Young-Shick
2016-04-20
Rice grain metabolites are important for better understanding of the plant physiology of various rice cultivars and thus for developing rice cultivars aimed at providing diverse processed products. However, the variation of global metabolites in rice grains has rarely been explored. Here, we report the identification of intra- or intercellular metabolites in rice (Oryza sativa L.) grain powder using a (1)H high-resolution magic angle spinning (HR-MAS) NMR-based metabolomic approach. Compared with nonwaxy rice cultivars, marked accumulation of lipid metabolites such as fatty acids, phospholipids, and glycerophosphocholine in the grains of waxy rice cultivars demonstrated the distinct metabolic regulation and adaptation of each cultivar for effective growth during future germination, which may be reflected by high levels of glutamate, aspartate, asparagine, alanine, and sucrose. Therefore, this study provides important insights into the metabolic variations of diverse rice cultivars and their associations with environmental conditions and genetic backgrounds, with the aim of facilitating efficient development and the improvement of rice grain quality through inbreeding with genetic or chemical modification and mutation.
Vermathen, Martina; Marzorati, Mattia; Diserens, Gaëlle; Baumgartner, Daniel; Good, Claudia; Gasser, Franz; Vermathen, Peter
2017-10-15
Determination of metabolic alterations in apples induced by such processes as different crop protection strategies or storage, are of interest to assess correlations with fruit quality or fruit disorders. Preliminary results proposed the metabolic discrimination of apples from organic (BIO), integrated (IP) and low-input (LI) production. To determine contributions of temporal metabolic developments and to define the type of metabolic changes during storage, 1 H high resolution-magic angle spinning (HR-MAS) NMR spectroscopy of apple pulp was performed before and after two time points of controlled atmosphere storage. Statistical analysis revealed similar metabolic changes over time for IP-, LI- and BIO-samples, mainly decreasing lipid and sucrose, and increasing fructose, glucose and acetaldehyde levels, which are potential contributors to fruit aroma. Across the production systems, BIO apples had consistently higher levels of fructose and monomeric phenolic compounds but lower levels of condensed polyphenols than LI and IP apples, while the remaining metabolites assimilated. Copyright © 2017 Elsevier Ltd. All rights reserved.
Long-Term Oxygen Therapy for Patients With Chronic Obstructive Pulmonary Disease (COPD)
2012-01-01
Executive Summary In July 2010, the Medical Advisory Secretariat (MAS) began work on a Chronic Obstructive Pulmonary Disease (COPD) evidentiary framework, an evidence-based review of the literature surrounding treatment strategies for patients with COPD. This project emerged from a request by the Health System Strategy Division of the Ministry of Health and Long-Term Care that MAS provide them with an evidentiary platform on the effectiveness and cost-effectiveness of COPD interventions. After an initial review of health technology assessments and systematic reviews of COPD literature, and consultation with experts, MAS identified the following topics for analysis: vaccinations (influenza and pneumococcal), smoking cessation, multidisciplinary care, pulmonary rehabilitation, long-term oxygen therapy, noninvasive positive pressure ventilation for acute and chronic respiratory failure, hospital-at-home for acute exacerbations of COPD, and telehealth (including telemonitoring and telephone support). Evidence-based analyses were prepared for each of these topics. For each technology, an economic analysis was also completed where appropriate. In addition, a review of the qualitative literature on patient, caregiver, and provider perspectives on living and dying with COPD was conducted, as were reviews of the qualitative literature on each of the technologies included in these analyses. The Chronic Obstructive Pulmonary Disease Mega-Analysis series is made up of the following reports, which can be publicly accessed at the MAS website at: http://www.hqontario.ca/en/mas/mas_ohtas_mn.html. Chronic Obstructive Pulmonary Disease (COPD) Evidentiary Framework Influenza and Pneumococcal Vaccinations for Patients With Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Smoking Cessation for Patients With Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Community-Based Multidisciplinary Care for Patients With Stable Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Pulmonary Rehabilitation for Patients With Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Long-term Oxygen Therapy for Patients With Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Noninvasive Positive Pressure Ventilation for Acute Respiratory Failure Patients With Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Noninvasive Positive Pressure Ventilation for Chronic Respiratory Failure Patients With Stable Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Hospital-at-Home Programs for Patients With Acute Exacerbations of Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Home Telehealth for Patients With Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Cost-Effectiveness of Interventions for Chronic Obstructive Pulmonary Disease Using an Ontario Policy Model Experiences of Living and Dying With COPD: A Systematic Review and Synthesis of the Qualitative Empirical Literature For more information on the qualitative review, please contact Mita Giacomini at: http://fhs.mcmaster.ca/ceb/faculty member_giacomini.htm. For more information on the economic analysis, please visit the PATH website: http://www.path-hta.ca/About-Us/Contact-Us.aspx. The Toronto Health Economics and Technology Assessment (THETA) collaborative has produced an associated report on patient preference for mechanical ventilation. For more information, please visit the THETA website: http://theta.utoronto.ca/static/contact. Objective The objective of this health technology assessment was to determine the effectiveness, cost-effectiveness, and safety of long-term oxygen therapy (LTOT) for chronic obstructive pulmonary disease (COPD). Clinical Need: Condition and Target Population Oxygen therapy is used in patients with COPD with hypoxemia, or very low blood oxygen levels, because they may have difficulty obtaining sufficient oxygen from inspired air. Technology Long-term oxygen therapy is extended use of oxygen. Oxygen therapy is delivered as a gas from an oxygen source. Different oxygen sources are: 1) oxygen concentrators, electrical units delivering oxygen converted from room air; 2) liquid oxygen systems, which deliver gaseous oxygen stored as liquid in a tank; and 3) oxygen cylinders, which contain compressed gaseous oxygen. All are available in portable versions. Oxygen is breathed in through a nasal cannula or through a mask covering the mouth and nose. The treating clinician determines the flow rate, duration of use, method of administration, and oxygen source according to individual patient needs. Two landmark randomized controlled trials (RCTs) of patients with COPD established the role of LTOT in COPD. Questions regarding the use of LTOT, however, still remain. Research Question What is the effectiveness, cost-effectiveness, and safety of LTOT compared with no LTOT in patients with COPD, who are stratified by severity of hypoxemia? Research Methods Literature Search Search Strategy A literature search was performed on September 8, 2010 using OVID MEDLINE, MEDLINE In-Process and Other Non-Indexed Citations, EMBASE, CINAHL, the Cochrane Library, and INAHTA for studies published from January 1, 2007 to September 8, 2010. A single clinical epidemiologist reviewed the abstracts, obtained full-text articles for studies meeting the eligibility criteria, and examined reference lists for additional relevant studies not identified through the literature search. A second clinical epidemiologist and then a group of epidemiologists reviewed articles with an unknown eligibility until consensus was established. Inclusion Criteria patients with mild, moderate, or severe hypoxemia; English-language articles published between January 1, 2007 and September 8, 2010; journal articles reporting on effectiveness, cost-effectiveness, or safety for the comparison of interest; clearly described study design and methods; health technology assessments, systematic reviews, RCTs, or prospective cohort observational studies; any type of observational study for the evaluation of safety. Exclusion Criteria no hypoxemia non-English papers animal or in vitro studies case reports, case series, or case-case studies studies comparing different oxygen therapy regimens studies on nocturnal oxygen therapy studies on short-burst, palliative, or ambulatory oxygen (supplemental oxygen during exercise or activities of daily living) Outcomes of Interest mortality/survival hospitalizations readmissions forced expiratory volume in 1 second (FEV1) forced vital capacity (FVC) FEV1/FVC pulmonary hypertension arterial partial pressure of oxygen (PaO2) arterial partial pressure of carbon dioxide (PaCO2) end-exercise dyspnea score endurance time health-related quality of life Note: Outcomes of interest were formulated according to existing studies, with arterial pressure of oxygen and carbon dioxide as surrogate outcomes. Summary of Findings Conclusions Based on low quality of evidence, LTOT (~ 15 hours/day) decreases all-cause mortality in patients with COPD who have severe hypoxemia (PaO2 ~ 50 mm Hg) and heart failure. The effect for all-cause mortality had borderline statistical significance when the control group was no LTOT: one study. Based on low quality of evidence, there is no beneficial effect of LTOT on all-cause mortality at 3 and 7 years in patients with COPD who have mild-to-moderate hypoxemia (PaO2 ~ 59-65 mm Hg)1 Based on very low quality of evidence, there is some suggestion that LTOT may have a beneficial effect over time on FEV1 and PaCO2 in patients with COPD who have severe hypoxemia and heart failure: improved methods are needed. Based on very low quality of evidence, there is no beneficial effect of LTOT on lung function or exercise factors in patients with COPD who have mild-to-moderate hypoxemia, whether survivors or nonsurvivors are assessed. Based on low to very low quality of evidence, LTOT does not prevent readmissions in patients with COPD who have severe hypoxemia. Limited data suggest LTOT increases the risk of hospitalizations. Limited work has been performed evaluating the safety of LTOT by severity of hypoxemia. Based on low to very low quality of evidence, LTOT may have a beneficial effect over time on health-related quality of life in patients with COPD who have severe hypoxemia. Limited work using disease-specific instruments has been performed. Ethical constraints of not providing LTOT to eligible patients with COPD prohibit future studies from examining LTOT outcomes in an ideal way. PMID:23074435
Home Telehealth for Patients With Chronic Obstructive Pulmonary Disease (COPD)
Franek, J
2012-01-01
Executive Summary In July 2010, the Medical Advisory Secretariat (MAS) began work on a Chronic Obstructive Pulmonary Disease (COPD) evidentiary framework, an evidence-based review of the literature surrounding treatment strategies for patients with COPD. This project emerged from a request by the Health System Strategy Division of the Ministry of Health and Long-Term Care that MAS provide them with an evidentiary platform on the effectiveness and cost-effectiveness of COPD interventions. After an initial review of health technology assessments and systematic reviews of COPD literature, and consultation with experts, MAS identified the following topics for analysis: vaccinations (influenza and pneumococcal), smoking cessation, multidisciplinary care, pulmonary rehabilitation, long-term oxygen therapy, noninvasive positive pressure ventilation for acute and chronic respiratory failure, hospital-at-home for acute exacerbations of COPD, and telehealth (including telemonitoring and telephone support). Evidence-based analyses were prepared for each of these topics. For each technology, an economic analysis was also completed where appropriate. In addition, a review of the qualitative literature on patient, caregiver, and provider perspectives on living and dying with COPD was conducted, as were reviews of the qualitative literature on each of the technologies included in these analyses. The Chronic Obstructive Pulmonary Disease Mega-Analysis series is made up of the following reports, which can be publicly accessed at the MAS website at: http://www.hqontario.ca/en/mas/mas_ohtas_mn.html. Chronic Obstructive Pulmonary Disease (COPD) Evidentiary Framework Influenza and Pneumococcal Vaccinations for Patients With Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Smoking Cessation for Patients With Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Community-Based Multidisciplinary Care for Patients With Stable Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Pulmonary Rehabilitation for Patients With Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Long-term Oxygen Therapy for Patients With Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Noninvasive Positive Pressure Ventilation for Acute Respiratory Failure Patients With Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Noninvasive Positive Pressure Ventilation for Chronic Respiratory Failure Patients With Stable Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Hospital-at-Home Programs for Patients With Acute Exacerbations of Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Home Telehealth for Patients With Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Cost-Effectiveness of Interventions for Chronic Obstructive Pulmonary Disease Using an Ontario Policy Model Experiences of Living and Dying With COPD: A Systematic Review and Synthesis of the Qualitative Empirical Literature For more information on the qualitative review, please contact Mita Giacomini at: http://fhs.mcmaster.ca/ceb/faculty_member_giacomini.htm. For more information on the economic analysis, please visit the PATH website: http://www.path-hta.ca/About-Us/Contact-Us.aspx. The Toronto Health Economics and Technology Assessment (THETA) collaborative has produced an associated report on patient preference for mechanical ventilation. For more information, please visit the THETA website: http://theta.utoronto.ca/static/contact. Objective The objective of this analysis was to conduct an evidence-based assessment of home telehealth technologies for patients with chronic obstructive pulmonary disease (COPD) in order to inform recommendations regarding the access and provision of these services in Ontario. This analysis was one of several analyses undertaken to evaluate interventions for COPD. The perspective of this assessment was that of the Ontario Ministry of Health and Long-Term Care, a provincial payer of medically necessary health care services. Clinical Need: Condition and Target Population Canada is facing an increase in chronic respiratory diseases due in part to its aging demographic. The projected increase in COPD will put a strain on health care payers and providers. There is therefore an increasing demand for telehealth services that improve access to health care services while maintaining or improving quality and equality of care. Many telehealth technologies however are in the early stages of development or diffusion and thus require study to define their application and potential harms or benefits. The Medical Advisory Secretariat (MAS) therefore sought to evaluate telehealth technologies for COPD. Technology Telemedicine (or telehealth) refers to using advanced information and communication technologies and electronic medical devices to support the delivery of clinical care, professional education, and health-related administrative services. Generally there are 4 broad functions of home telehealth interventions for COPD: to monitor vital signs or biological health data (e.g., oxygen saturation), to monitor symptoms, medication, or other non-biologic endpoints (e.g., exercise adherence), to provide information (education) and/or other support services (such as reminders to exercise or positive reinforcement), and to establish a communication link between patient and provider. These functions often require distinct technologies, although some devices can perform a number of these diverse functions. For the purposes of this review, MAS focused on home telemonitoring and telephone only support technologies. Telemonitoring (or remote monitoring) refers to the use of medical devices to remotely collect a patient’s vital signs and/or other biologic health data and the transmission of those data to a monitoring station for interpretation by a health care provider. Telephone only support refers to disease/disorder management support provided by a health care provider to a patient who is at home via telephone or videoconferencing technology in the absence of transmission of patient biologic data. Research Questions What is the effectiveness, cost-effectiveness, and safety of home telemonitoring compared with usual care for patients with COPD? What is the effectiveness, cost-effectiveness, and safety of telephone only support programs compared with usual care for patients with COPD? Research Methods Literature Search Search Strategy A literature search was performed on November 3, 2010 using OVID MEDLINE, MEDLINE In-Process and Other Non-Indexed Citations, EMBASE, the Cumulative Index to Nursing & Allied Health Literature (CINAHL), the Cochrane Library, and the International Agency for Health Technology Assessment (INAHTA) for studies published from January 1, 2000 until November 3, 2010. Abstracts were reviewed by a single reviewer and, for those studies meeting the eligibility criteria, full-text articles were obtained. Reference lists were also examined for any additional relevant studies not identified through the search. Articles with unknown eligibility were reviewed with a second clinical epidemiologist, and then a group of epidemiologists until consensus was established. The quality of evidence was assessed as high, moderate, low, or very low according to GRADE methodology. Inclusion Criteria – Question #1 frequent transmission of a patient’s physiological data collected at home and without a health care professional physically present to health care professionals for routine monitoring through the use of a communication technology; monitoring combined with a coordinated management and feedback system based on transmitted data; telemonitoring as a key component of the intervention (subjective determination); usual care as provided by the usual care provider for the control group; randomized controlled trials (RCTs), controlled clinical trials (CCTs), systematic reviews, and/or meta-analyses; published between January 1, 2000 and November 3, 2010. Inclusion Criteria – Question #2 scheduled or frequent contact between patient and a health care professional via telephone or videoconferencing technology in the absence of transmission of patient physiological data; monitoring combined with a coordinated management and feedback system based on transmitted data; telephone support as a key component of the intervention (subjective determination); usual care as provided by the usual care provider for the control group; RCTs, CCTs, systematic reviews, and/or meta-analyses; published between January 1, 2000 and November 3, 2010. Exclusion Criteria published in a language other than English; intervention group (and not control) receiving some form of home visits by a medical professional, typically a nurse (i.e., telenursing) beyond initial technology set-up and education, to collect physiological data, or to somehow manage or treat the patient; not recording patient or health system outcomes (e.g., technical reports testing accuracy, reliability or other development-related outcomes of a device, acceptability/feasibility studies, etc.); not using an independent control group that received usual care (e.g., studies employing historical or periodic controls). Outcomes of Interest hospitalizations (primary outcome) mortality emergency department visits length of stay quality of life other […] Subgroup Analyses (a priori) length of intervention (primary) severity of COPD (primary) Quality of Evidence The quality of evidence assigned to individual studies was determined using a modified CONSORT Statement Checklist for Randomized Controlled Trials. (1) The CONSORT Statement was adapted to include 3 additional quality measures: the adequacy of control group description, significant differential loss to follow-up between groups, and greater than or equal to 30% study attrition. Individual study quality was defined based on total scores according to the CONSORT Statement checklist: very low (0 to < 40%), low (≥ 40 to < 60%), moderate (≥ 60 to < 80%), and high (≥ 80 to 100%). The quality of the body of evidence was assessed as high, moderate, low, or very low according to the GRADE Working Group criteria. The following definitions of quality were used in grading the quality of the evidence: High Further research is very unlikely to change confidence in the estimate of effect. Moderate Further research is likely to have an important impact on confidence in the estimate of effect and may change the estimate. Low Further research is very likely to have an important impact on confidence in the estimate of effect and is likely to change the estimate. Very Low Any estimate of effect is very uncertain. Summary of Findings Six publications, representing 5 independent trials, met the eligibility criteria for Research Question #1. Three trials were RCTs reported across 4 publications, whereby patients were randomized to home telemonitoring or usual care, and 2 trials were CCTs, whereby patients or health care centers were nonrandomly assigned to intervention or usual care. A total of 310 participants were studied across the 5 included trials. The mean age of study participants in the included trials ranged from 61.2 to 74.5 years for the intervention group and 61.1 to 74.5 years for the usual care group. The percentage of men ranged from 40% to 64% in the intervention group and 46% to 72% in the control group. All 5 trials were performed in a moderate to severe COPD patient population. Three trials initiated the intervention following discharge from hospital. One trial initiated the intervention following a pulmonary rehabilitation program. The final trial initiated the intervention during management of patients at an outpatient clinic. Four of the 5 trials included oxygen saturation (i.e., pulse oximetry) as one of the biological patient parameters being monitored. Additional parameters monitored included forced expiratory volume in one second, peak expiratory flow, and temperature. There was considerable clinical heterogeneity between trials in study design, methods, and intervention/control. In relation to the telemonitoring intervention, 3 of the 5 included studies used an electronic health hub that performed multiple functions beyond the monitoring of biological parameters. One study used only a pulse oximeter device alone with modem capabilities. Finally, in 1 study, patients measured and then forwarded biological data to a nurse during a televideo consultation. Usual care varied considerably between studies. Only one trial met the eligibility criteria for Research Question #2. The included trial was an RCT that randomized 60 patients to nurse telephone follow-up or usual care (no telephone follow-up). Participants were recruited from the medical department of an acute-care hospital in Hong Kong and began receiving follow-up after discharge from the hospital with a diagnosis of COPD (no severity restriction). The intervention itself consisted of only two 10-to 20-minute telephone calls, once between days 3 to 7 and once between days 14 to 20, involving a structured, individualized educational and supportive programme led by a nurse that focused on 3 components: assessment, management options, and evaluation. Regarding Research Question #1: Low to very low quality evidence (according to GRADE) finds non-significant effects or conflicting effects (of significant or non-significant benefit) for all outcomes examined when comparing home telemonitoring to usual care. There is a trend towards significant increase in time free of hospitalization and use of other health care services with home telemonitoring, but these findings need to be confirmed further in randomized trials of high quality. There is severe clinical heterogeneity between studies that limits summary conclusions. The economic impact of home telemonitoring is uncertain and requires further study. Home telemonitoring is largely dependent on local information technologies, infrastructure, and personnel, and thus the generalizability of external findings may be low. Jurisdictions wishing to replicate home telemonitoring interventions should likely test those interventions within their jurisdictional framework before adoption, or should focus on home-grown interventions that are subjected to appropriate evaluation and proven effective. Regarding Research Question #2: Low quality evidence finds significant benefit in favour of telephone-only support for self-efficacy and emergency department visits when compared to usual care, but non-significant results for hospitalizations and hospital length of stay. There are very serious issues with the generalizability of the evidence and thus additional research is required. PMID:23074421
ERIC Educational Resources Information Center
Albus, Deb; Thurlow, Martha L.; Lazarus, Sheryl S.
2011-01-01
This report examines publicly reported participation and performance data for the alternate assessment based on modified achievement standards (AA-MAS). The authors' analysis of these data included all states publicly reporting AA-MAS data, regardless of whether they had received approval to use the results for Title I accountability calculations.…
USDA-ARS?s Scientific Manuscript database
Cornelian cherry (Cornus mas L.) is indigenous to central and southeastern Europe and is an ecologically and economically important shrub or small tree. The aim of this study was to develop molecular tools for assessing genetic diversity and provide unique molecular identification of C. mas cultivar...
Krueger, Eddy; Scheeren, Eduardo M; Nogueira-Neto, Guilherme N; Button, Vera Lúcia da S N; Nohama, Percy
2012-01-01
Several pathologies can cause muscle spasticity. Modified Ashworth scale (MAS) can rank spasticity, however its results depend on the physician subjective evaluation. This study aims to show a new approach to spasticity assessment by means of MMG analysis of hamstrings antagonist muscle group (quadriceps muscle). Four subjects participated in the study, divided into two groups regarding MAS (MAS0 and MAS1). MMG sensors were positioned over the muscle belly of rectus femoris (RF), vastus lateralis (VL) and vastus medialis (VM) muscles. The range of movement was acquired with an electrogoniometer placed laterally to the knee. The system was based on a LabVIEW acquisition program and the MMG sensors were built with triaxial accelerometers. The subjects were submitted to stretching reflexes and the integral of the MMG (MMG(INT)) signal was calculated to analysis. The results showed that the MMG(INT) was greater to MAS1 than to MAS0 [muscle RF (p = 0.004), VL (p = 0.001) and VM (p = 0.007)]. The results showed that MMG was viable to detect a muscular tonus increase in antagonist muscular group (quadriceps femoris) of spinal cord injured volunteers.
Castritius, Stefan; Kron, Alexander; Schäfer, Thomas; Rädle, Matthias; Harms, Diedrich
2010-12-22
A new approach of combination of near-infrared (NIR) spectroscopy and refractometry was developed in this work to determine the concentration of alcohol and real extract in various beer samples. A partial least-squares (PLS) regression, as multivariate calibration method, was used to evaluate the correlation between the data of spectroscopy/refractometry and alcohol/extract concentration. This multivariate combination of spectroscopy and refractometry enhanced the precision in the determination of alcohol, compared to single spectroscopy measurements, due to the effect of high extract concentration on the spectral data, especially of nonalcoholic beer samples. For NIR calibration, two mathematical pretreatments (first-order derivation and linear baseline correction) were applied to eliminate light scattering effects. A sample grouping of the refractometry data was also applied to increase the accuracy of the determined concentration. The root mean squared errors of validation (RMSEV) of the validation process concerning alcohol and extract concentration were 0.23 Mas% (method A), 0.12 Mas% (method B), and 0.19 Mas% (method C) and 0.11 Mas% (method A), 0.11 Mas% (method B), and 0.11 Mas% (method C), respectively.
Jarlbring, Mathias; Sandström, Dan E; Antzutkin, Oleg N; Forsling, Willis
2006-05-09
The chemically active phosphorus surface sites defined as PO(x), PO(x)H, and PO(x)H2, where x = 1, 2, or 3, and the bulk phosphorus groups of PO4(3-) at synthetic carbonate-free fluorapatite (Ca5(PO4)3F) have been studied by means of single-pulse 1H,31P, and 31P CP MAS NMR. The changes in composition and relative amounts of each surface species are evaluated as a function of pH. By combining spectra from single-pulse 1H and 31P MAS NMR and data from 31P CP MAS NMR experiments at varying contact times in the range 0.2-3.0 ms, it has been possible to distinguish between resonance lines in the NMR spectra originating from active surface sites and bulk phosphorus groups and also to assign the peaks in the NMR spectra to the specific phosphorus species. In the 31P CP MAS NMR experiments, the spinning frequency was set to 4.2 kHz; in the single-pulse 1H MAS NMR experiments, the spinning frequency was 10 kHz. The 31P CP MAS NMR spectrum of fluorapatite at pH 5.9 showed one dominating resonance line at 2.9 ppm assigned to originate from PO4(3-) groups and two weaker shoulder peaks at 5.4 and 0.8 ppm which were assigned to the unprotonated PO(x) (PO, PO2-, and PO3(2-)) and protonated PO(x)H (PO2H and PO3H-) surface sites. At pH 12.7, the intensity of the peak representing unprotonated PO(x) surface sites has increased 1.7% relative to the bulk peak, while the intensity of the peaks of the protonated species PO(x)H have decreased 1.4% relative to the bulk peak. At pH 3.5, a resonance peak at -4.5 ppm has appeared in the 31P CP MAS NMR spectrum assigned to the surface species PO(x)H2 (PO3H2). The results from the 1H MAS and 31P CP MAS NMR measurements indicated that H+, OH-, and physisorbed H2O at the surface were released during the drying process at 200 degrees C.
Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner
Kakinuma, Ryutaro; Moriyama, Noriyuki; Muramatsu, Yukio; Gomi, Shiho; Suzuki, Masahiro; Nagasawa, Hirobumi; Kusumoto, Masahiko; Aso, Tomohiko; Muramatsu, Yoshihisa; Tsuchida, Takaaki; Tsuta, Koji; Maeshima, Akiko Miyagi; Tochigi, Naobumi; Watanabe, Shun-ichi; Sugihara, Naoki; Tsukagoshi, Shinsuke; Saito, Yasuo; Kazama, Masahiro; Ashizawa, Kazuto; Awai, Kazuo; Honda, Osamu; Ishikawa, Hiroyuki; Koizumi, Naoya; Komoto, Daisuke; Moriya, Hiroshi; Oda, Seitaro; Oshiro, Yasuji; Yanagawa, Masahiro; Tomiyama, Noriyuki; Asamura, Hisao
2015-01-01
Purpose The image noise and image quality of a prototype ultra-high-resolution computed tomography (U-HRCT) scanner was evaluated and compared with those of conventional high-resolution CT (C-HRCT) scanners. Materials and Methods This study was approved by the institutional review board. A U-HRCT scanner prototype with 0.25 mm x 4 rows and operating at 120 mAs was used. The C-HRCT images were obtained using a 0.5 mm x 16 or 0.5 mm x 64 detector-row CT scanner operating at 150 mAs. Images from both scanners were reconstructed at 0.1-mm intervals; the slice thickness was 0.25 mm for the U-HRCT scanner and 0.5 mm for the C-HRCT scanners. For both scanners, the display field of view was 80 mm. The image noise of each scanner was evaluated using a phantom. U-HRCT and C-HRCT images of 53 images selected from 37 lung nodules were then observed and graded using a 5-point score by 10 board-certified thoracic radiologists. The images were presented to the observers randomly and in a blinded manner. Results The image noise for U-HRCT (100.87 ± 0.51 Hounsfield units [HU]) was greater than that for C-HRCT (40.41 ± 0.52 HU; P < .0001). The image quality of U-HRCT was graded as superior to that of C-HRCT (P < .0001) for all of the following parameters that were examined: margins of subsolid and solid nodules, edges of solid components and pulmonary vessels in subsolid nodules, air bronchograms, pleural indentations, margins of pulmonary vessels, edges of bronchi, and interlobar fissures. Conclusion Despite a larger image noise, the prototype U-HRCT scanner had a significantly better image quality than the C-HRCT scanners. PMID:26352144
English, René; Peer, Nazia; Honikman, Simone; Tugendhaft, Aviva; Hofman, Karen J
2017-01-01
In South Africa (SA), despite adoption of international strategies and approaches, maternal, neonatal and child (MNC) morbidity and mortality rates have not sufficiently declined. To conduct an umbrella review (UR) that identifies interventions in low- and middle-income countries, with a high-quality evidence base, that improve MNC morbidity and mortality outcomes within the first 1000 days of life; and to assess the incorporation of the evidence into local strategies, guidelines and documents. We included publications about women and children in the first 1000 days of life; healthcare professionals and community members. Comparators were those who did not receive the intervention. Interventions were pharmacological and non-pharmacological. Outcomes were MNC morbidity and mortality. Authors conducted English language electronic and manual searches (2000-2013). The quality of systematic reviews and meta-analyses (SRs/MAs) were reviewed. Interventions were ranked according to level of evidence; and then aligned with SA strategies, policies and guidelines. A tool to extract data was developed and used by two authors who independently extracted data. Summary measures from MAs or summaries of SRs were reviewed and the specificities of the various interventions listed. A search of all local high-level documents was done and these were assessed to determine the specificities of the recommendations and their alignment to the evidence. In total, 19 interventions presented in 32 SRs were identified. Overall, SA's policymakers have sufficiently included high-quality evidence-based interventions into local policies. However, optimal period of birth spacing (two to five years) is not explicitly promoted nor was ante- and postnatal depression adequately incorporated. Antenatal care visits should be increased from four to about eight according to the evidence. Incorporation of existing evidence into policies can be strengthened in SA. The UR methods are useful to inform policymaking and identify research gaps. RESPONSIBLE EDITOR Nawi Ng, Umeå University, Sweden.
English, René; Peer, Nazia; Honikman, Simone; Tugendhaft, Aviva; Hofman, Karen J
2017-01-01
ABSTRACT Background: In South Africa (SA), despite adoption of international strategies and approaches, maternal, neonatal and child (MNC) morbidity and mortality rates have not sufficiently declined. Objectives: To conduct an umbrella review (UR) that identifies interventions in low- and middle-income countries, with a high-quality evidence base, that improve MNC morbidity and mortality outcomes within the first 1000 days of life; and to assess the incorporation of the evidence into local strategies, guidelines and documents. Methods: We included publications about women and children in the first 1000 days of life; healthcare professionals and community members. Comparators were those who did not receive the intervention. Interventions were pharmacological and non-pharmacological. Outcomes were MNC morbidity and mortality. Authors conducted English language electronic and manual searches (2000–2013). The quality of systematic reviews and meta-analyses (SRs/MAs) were reviewed. Interventions were ranked according to level of evidence; and then aligned with SA strategies, policies and guidelines. A tool to extract data was developed and used by two authors who independently extracted data. Summary measures from MAs or summaries of SRs were reviewed and the specificities of the various interventions listed. A search of all local high-level documents was done and these were assessed to determine the specificities of the recommendations and their alignment to the evidence. Results: In total, 19 interventions presented in 32 SRs were identified. Overall, SA’s policymakers have sufficiently included high-quality evidence-based interventions into local policies. However, optimal period of birth spacing (two to five years) is not explicitly promoted nor was ante- and postnatal depression adequately incorporated. Antenatal care visits should be increased from four to about eight according to the evidence. Conclusion: Incorporation of existing evidence into policies can be strengthened in SA. The UR methods are useful to inform policymaking and identify research gaps. RESPONSIBLE EDITOR Nawi Ng, Umeå University, Sweden PMID:28715934
Validation of a low dose simulation technique for computed tomography images.
Muenzel, Daniela; Koehler, Thomas; Brown, Kevin; Zabić, Stanislav; Fingerle, Alexander A; Waldt, Simone; Bendik, Edgar; Zahel, Tina; Schneider, Armin; Dobritz, Martin; Rummeny, Ernst J; Noël, Peter B
2014-01-01
Evaluation of a new software tool for generation of simulated low-dose computed tomography (CT) images from an original higher dose scan. Original CT scan data (100 mAs, 80 mAs, 60 mAs, 40 mAs, 20 mAs, 10 mAs; 100 kV) of a swine were acquired (approved by the regional governmental commission for animal protection). Simulations of CT acquisition with a lower dose (simulated 10-80 mAs) were calculated using a low-dose simulation algorithm. The simulations were compared to the originals of the same dose level with regard to density values and image noise. Four radiologists assessed the realistic visual appearance of the simulated images. Image characteristics of simulated low dose scans were similar to the originals. Mean overall discrepancy of image noise and CT values was -1.2% (range -9% to 3.2%) and -0.2% (range -8.2% to 3.2%), respectively, p>0.05. Confidence intervals of discrepancies ranged between 0.9-10.2 HU (noise) and 1.9-13.4 HU (CT values), without significant differences (p>0.05). Subjective observer evaluation of image appearance showed no visually detectable difference. Simulated low dose images showed excellent agreement with the originals concerning image noise, CT density values, and subjective assessment of the visual appearance of the simulated images. An authentic low-dose simulation opens up opportunity with regard to staff education, protocol optimization and introduction of new techniques.
Guillaume, François; Fritz, Sébastien; Boichard, Didier; Druet, Tom
2008-01-01
The efficiency of the French marker-assisted selection (MAS) was estimated by a simulation study. The data files of two different time periods were used: April 2004 and 2006. The simulation method used the structure of the existing French MAS: same pedigree, same marker genotypes and same animals with records. The program simulated breeding values and new records based on this existing structure and knowledge on the QTL used in MAS (variance and frequency). Reliabilities of genetic values of young animals (less than one year old) obtained with and without marker information were compared to assess the efficiency of MAS for evaluation of milk, fat and protein yields and fat and protein contents. Mean gains of reliability ranged from 0.015 to 0.094 and from 0.038 to 0.114 in 2004 and 2006, respectively. The larger number of animals genotyped and the use of a new set of genetic markers can explain the improvement of MAS reliability from 2004 to 2006. This improvement was also observed by analysis of information content for young candidates. The gain of MAS reliability with respect to classical selection was larger for sons of sires with genotyped progeny daughters with records. Finally, it was shown that when superiority of MAS over classical selection was estimated with daughter yield deviations obtained after progeny test instead of true breeding values, the gain was underestimated. PMID:18096117
Resolution of donor non-alcoholic fatty liver disease following liver transplantation.
Posner, Andrew D; Sultan, Samuel T; Zaghloul, Norann A; Twaddell, William S; Bruno, David A; Hanish, Steven I; Hutson, William R; Hebert, Laci; Barth, Rolf N; LaMattina, John C
2017-09-01
Transplant surgeons conventionally select against livers displaying high degrees (>30%) of macrosteatosis (MaS), out of concern for primary non-function or severe graft dysfunction. As such, there is relatively limited experience with such livers, and the natural history remains incompletely characterized. We present our experience of transplanted livers with high degrees of MaS and microsteatosis (MiS), with a focus on the histopathologic and clinical outcomes. Twenty-nine cases were identified with liver biopsies available from both the donor and the corresponding liver transplant recipient. Donor liver biopsies displayed either MaS or MiS ≥15%, while all recipients received postoperative liver biopsies for cause. The mean donor MaS and MiS were 15.6% (range 0%-60%) and 41.3% (7.5%-97.5%), respectively. MaS decreased significantly from donor (M=15.6%) to recipient postoperative biopsies (M=0.86%), P<.001. Similarly, MiS decreased significantly from donor biopsies (M=41.3%) to recipient postoperative biopsies (M=1.8%), P<.001. At a median of 68 days postoperatively (range 4-384), full resolution of MaS and MiS was observed in 27 of 29 recipients. High degrees of MaS and MiS in donor livers resolve in recipients following liver transplantation. Further insight into the mechanisms responsible for treating fatty liver diseases could translate into therapeutic targets. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Positioning Medical Assistants for a Greater Role in the Era of Health Reform.
Chapman, Susan A; Marks, Angela; Dower, Catherine
2015-10-01
Medical assistants (MAs) are one of the fastest-growing occupations in the United States. As of 2014 there were about 585,000 MAs in the United States, and the Bureau of Labor Statistics projected the MA workforce to grow by 29% from 2012 to 2022. The MA population is primarily female, ethnically and racially diverse, and paid about $15.01 per hour. MAs are primarily educated in private schools, many at for-profit institutions. The MA curriculum and length of training can be quite varied and can lead to uneven preparation for practice. Traditionally, the MA role has involved a limited clinical role and little involvement with team care, particularly in larger practices or clinics. Medical groups, clinics, and health systems are now taking a new look at MAs and how they can play a greater role in reforming health care delivery models. Expanded roles for MAs might include health coach, referral coordinator, disease registry manager, and health screener using protocols. In expanding MA roles, education and regulatory issues need to be addressed by the provider community including current inconsistent regulation and certification requirements and the lack of preparation for expanded roles in traditional MA training programs. MAs are well positioned to help address challenges in the health care delivery system including improving access to care while reducing overall cost. Successful model practices using MAs in expanded roles need further formal evaluation and replication across practice settings.
Pulmonary Rehabilitation for Patients With Chronic Pulmonary Disease (COPD)
2012-01-01
Executive Summary In July 2010, the Medical Advisory Secretariat (MAS) began work on a Chronic Obstructive Pulmonary Disease (COPD) evidentiary framework, an evidence-based review of the literature surrounding treatment strategies for patients with COPD. This project emerged from a request by the Health System Strategy Division of the Ministry of Health and Long-Term Care that MAS provide them with an evidentiary platform on the effectiveness and cost-effectiveness of COPD interventions. After an initial review of health technology assessments and systematic reviews of COPD literature, and consultation with experts, MAS identified the following topics for analysis: vaccinations (influenza and pneumococcal), smoking cessation, multidisciplinary care, pulmonary rehabilitation, long-term oxygen therapy, noninvasive positive pressure ventilation for acute and chronic respiratory failure, hospital-at-home for acute exacerbations of COPD, and telehealth (including telemonitoring and telephone support). Evidence-based analyses were prepared for each of these topics. For each technology, an economic analysis was also completed where appropriate. In addition, a review of the qualitative literature on patient, caregiver, and provider perspectives on living and dying with COPD was conducted, as were reviews of the qualitative literature on each of the technologies included in these analyses. The Chronic Obstructive Pulmonary Disease Mega-Analysis series is made up of the following reports, which can be publicly accessed at the MAS website at: http://www.hqontario.ca/en/mas/mas_ohtas_mn.html. Chronic Obstructive Pulmonary Disease (COPD) Evidentiary Framework Influenza and Pneumococcal Vaccinations for Patients With Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Smoking Cessation for Patients With Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Community-Based Multidisciplinary Care for Patients With Stable Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Pulmonary Rehabilitation for Patients With Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Long-term Oxygen Therapy for Patients With Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Noninvasive Positive Pressure Ventilation for Acute Respiratory Failure Patients With Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Noninvasive Positive Pressure Ventilation for Chronic Respiratory Failure Patients With Stable Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Hospital-at-Home Programs for Patients With Acute Exacerbations of Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Home Telehealth for Patients With Chronic Obstructive Pulmonary Disease (COPD): An Evidence-Based Analysis Cost-Effectiveness of Interventions for Chronic Obstructive Pulmonary Disease Using an Ontario Policy Model Experiences of Living and Dying With COPD: A Systematic Review and Synthesis of the Qualitative Empirical Literature For more information on the qualitative review, please contact Mita Giacomini at: http://fhs.mcmaster.ca/ceb/faculty member_giacomini.htm. For more information on the economic analysis, please visit the PATH website: http://www.path-hta.ca/About-Us/Contact-Us.aspx. The Toronto Health Economics and Technology Assessment (THETA) collaborative has produced an associated report on patient preference for mechanical ventilation. For more information, please visit the THETA website: http://theta.utoronto.ca/static/contact. Objective The objective of this evidence-based review was to determine the effectiveness and cost-effectiveness of pulmonary rehabilitation in the management of chronic obstructive pulmonary disease (COPD). Technology Pulmonary rehabilitation refers to a multidisciplinary program of care for patients with chronic respiratory impairment that is individually tailored and designed to optimize physical and social performance and autonomy. Exercise training is the cornerstone of pulmonary rehabilitation programs, though they may also include components such as patient education and psychological support. Pulmonary rehabilitation is recommended as the standard of care in the treatment and rehabilitation of patients with COPD who remain symptomatic despite treatment with bronchodilators. For the purpose of this review, the Medical Advisory Secretariat focused on pulmonary rehabilitation programs as defined by the Cochrane Collaboration—that is, any inpatient, outpatient, or home-based rehabilitation program lasting at least 4 weeks that includes exercise therapy with or without any form of education and/or psychological support delivered to patients with exercise limitations attributable to COPD. Research Questions What is the effectiveness and cost-effectiveness of pulmonary rehabilitation compared with usual care (UC) for patients with stable COPD? Does early pulmonary rehabilitation (within 1 month of hospital discharge) in patients who had an acute exacerbation of COPD improve outcomes compared with UC (or no rehabilitation)? Do maintenance or postrehabilitation programs for patients with COPD who have completed a pulmonary rehabilitation program improve outcomes compared with UC? Research Methods Literature Search Search Strategy For Research Questions 1and 2, a literature search was performed on August 10, 2010 for studies published from January 1, 2004 to July 31, 2010. For Research Question 3, a literature search was performed on February 3, 2011 for studies published from January 1, 2000 to February 3, 2011. Abstracts were reviewed by a single reviewer and, for those studies meeting the eligibility criteria, full-text articles were obtained. Reference lists and health technology assessment websites were also examined for any additional relevant studies not identified through the systematic search. Inclusion Criteria Research questions 1 and 2: published between January 1, 2004 and July 31, 2010 randomized controlled trials, systematic reviews, and meta-analyses COPD study population studies comparing pulmonary rehabilitation with UC (no pulmonary rehabilitation) duration of pulmonary rehabilitation program ≥ 6 weeks pulmonary rehabilitation program had to include at minimum exercise training Research question 3: published between January 1, 2000 and February 3, 2011 randomized controlled trials, systematic reviews, and meta-analyses COPD study population studies comparing a maintenance or postrehabilitation program with UC (standard follow-up) duration of pulmonary rehabilitation program ≥ 6 weeks initial pulmonary rehabilitation program had to include at minimum exercise training Exclusion Criteria Research questions 1, 2, and 3: grey literature duplicate publications non-English language publications study population ≤ 18 years of age studies conducted in a palliative population studies that did not report primary outcome of interest Additional exclusion criteria for research question 3: studies with ≤ 2 sessions/visits per month Outcomes of Interest The primary outcomes of interest for the stable COPD population were exercise capacity and health-related quality of life (HRQOL). For the COPD population following an exacerbation, the primary outcomes of interest were hospital readmissions and HRQOL. The primary outcomes of interest for the COPD population undertaking maintenance programs were functional exercise capacity and HRQOL. Quality of Evidence The quality of each included study was assessed taking into consideration allocation concealment, randomization, blinding, power/sample size, withdrawals/dropouts, and intention-to-treat analyses. The quality of the body of evidence was assessed as high, moderate, low, or very low according to the GRADE Working Group criteria. The following definitions of quality were used in grading the quality of the evidence: High Further research is very unlikely to change confidence in the estimate of effect. Moderate Further research is likely to have an important impact on confidence in the estimate of effect and may change the estimate. Low Further research is very likely to have an important impact on confidence in the estimate of effect and is likely to change the estimate. Very Low Any estimate of effect is very uncertain. Summary of Findings Research Question 1: Effect of Pulmonary Rehabilitation on Outcomes in Stable COPD Seventeen randomized controlled trials met the inclusion criteria and were included in this review. The following conclusions are based on moderate quality of evidence. Pulmonary rehabilitation including at least 4 weeks of exercise training leads to clinically and statistically significant improvements in HRQOL in patients with COPD.1 Pulmonary rehabilitation also leads to a clinically and statistically significant improvement in functional exercise capacity2 (weighted mean difference, 54.83 m; 95% confidence interval, 35.63–74.03; P < 0.001). Research Question 2: Effect of Pulmonary Rehabilitation on Outcomes Following an Acute Exacerbation of COPD Five randomized controlled trials met the inclusion criteria and are included in this review. The following conclusion is based on moderate quality of evidence. Pulmonary rehabilitation (within 1 month of hospital discharge) after acute exacerbation significantly reduces hospital readmissions (relative risk, 0.50; 95% confidence interval, 0.33–0.77; P = 0.001) and leads to a statistically and clinically significant improvement in HRQOL.3 Research Question 3: Effect of Pulmonary Rehabilitation Maintenance Programs on COPD Outcomes Three randomized controlled trials met the inclusion criteria and are included in this review. The conclusions are based on a low quality of evidence and must therefore be considered with caution. Maintenance programs have a nonsignificant effect on HRQOL and hospitalizations. Maintenance programs have a statistically but not clinically significant effect on exercise capacity (P = 0.01). When subgrouped by intensity and quality of study, maintenance programs have a statistically and marginally clinically significant effect on exercise capacity. PMID:23074434
Larsen, Flemming H; Schöbitz, Michael; Schaller, Jens
2012-06-20
The hydration properties of 2,3-O-hydroxypropylcellulose (HPC) and 2,3-O-hydroxyethylcellulose (HEC) were analyzed by multi-nuclear solid-state MAS NMR spectroscopy. By 13C single-pulse (SP) MAS and cross-polarization (CP) MAS NMR, differences between the immobile regions and all parts of the polysaccharides were detected as a function of hydration. Complementary information about the water environments was observed by 2H MAS NMR. By this approach it was demonstrated that side chains in 2,3-O-HPC and 2,3-O-HEC were easier to hydrate than the cellulose backbone. Furthermore the motion of water was more restricted (slower) in 2,3-O-HPC than in 2,3-O-HEC. For both polysaccharides the hydration could be explained by a two-step process: in step one increased ordering of the immobile regions occurs after which the entire polymer is hydrated in step two. Copyright © 2012 Elsevier Ltd. All rights reserved.
Venâncio, Tiago; Oliveira, Lyege Magalhaes; Ellena, Javier; Boechat, Nubia; Brown, Steven P
2017-10-01
Fast magic-angle spinning (MAS) NMR is used to probe intermolecular interactions in a diethylcarbamazine salt, that is widely used as a treatment against adult worms of Wuchereria bancrofti which cause a common disease in tropical countries named filariasis. Specifically, a dihydrogen citrate salt that has improved thermal stability and solubility as compared to the free form is studied. One-dimensional 1 H, 13 C and 15 N and two-dimensional 1 H- 13 C and 14 N- 1 H heteronuclear correlation NMR experiments under moderate and fast MAS together with GIPAW (CASTEP) calculations enable the assignment of the 1 H, 13 C and 14 N/ 15 N resonances. A two-dimensional 1 H- 1 H double-quantum (DQ) -single-quantum (SQ) MAS spectrum recorded with BaBa recoupling at 60kHz MAS identifies specific proton-proton proximities associated with citrate-citrate and citrate-diethylcarbamazine intermolecular interactions. Copyright © 2017 Elsevier Inc. All rights reserved.
Time Series Forecasting of the Number of Malaysia Airlines and AirAsia Passengers
NASA Astrophysics Data System (ADS)
Asrah, N. M.; Nor, M. E.; Rahim, S. N. A.; Leng, W. K.
2018-04-01
The standard practice in forecasting process involved by fitting a model and further analysis on the residuals. If we know the distributional behaviour of the time series data, it can help us to directly analyse the model identification, parameter estimation, and model checking. In this paper, we want to compare the distributional behaviour data from the number of Malaysia Airlines (MAS) and AirAsia passenger’s. From the previous research, the AirAsia passengers are govern by geometric Brownian motion (GBM). The data were normally distributed, stationary and independent. Then, GBM was used to forecast the number of AirAsia passenger’s. The same methods were applied to MAS data and the results then were compared. Unfortunately, the MAS data were not govern by GBM. Then, the standard approach in time series forecasting will be applied to MAS data. From this comparison, we can conclude that the number of AirAsia passengers are always in peak season rather than MAS passengers.
The Parallax of the Red Hypergiant VX Sgr with Accurate Tropospheric Delay Calibration
NASA Astrophysics Data System (ADS)
Xu, Shuangjing; Zhang, Bo; Reid, Mark J.; Menten, Karl M.; Zheng, Xingwu; Wang, Guangli
2018-05-01
We report astrometric results of VLBI phase-referencing observations of 22 GHz H2O masers emission toward the red hypergiant VX Sgr, one of most massive and luminous red hypergiant stars in our Galaxy, using the Very Long Baseline Array. A background source, J1820‑2528, projected 4.°4 from the target VX Sgr, was used as the phase reference. For the low decl. of these sources, such a large separation normally would seriously degrade the relative astrometry. We use a two-step method of tropospheric delay calibration, which combines the VLBI geodetic-block (or Global Positioning System) calibration with an image-optimization calibration, to obtain a trigonometric parallax of 0.64 ± 0.04 mas, corresponding to a distance of {1.56}-0.10+0.11 kpc. The measured proper motion of VX Sgr is 0.36 ± 0.76 and ‑2.92 ± 0.78 mas yr‑1 in the eastward and northward directions. The parallax and proper motion confirms that VX Sgr belong to the Sgr OB1 association. Rescaling bolometric luminosities in the literature to our parallax distance, we find that the luminosity of VX Sgr is (1.95 ± 0.62) × 105 L ⊙, where the uncertainty is dominated by differing photometry measurements.
A LOW-E MAGIC ANGLE SPINNING PROBE FOR BIOLOGICAL SOLID STATE NMR AT 750 MHz
McNeill, Seth A.; Gor’kov, Peter L.; Shetty, Kiran; Brey, William W.; Long, Joanna R.
2009-01-01
Crossed-coil NMR probes are a useful tool for reducing sample heating for biological solid state NMR. In a crossed-coil probe, the higher frequency 1H field, which is the primary source of sample heating in conventional probes, is produced by a separate low-inductance resonator. Because a smaller driving voltage is required, the electric field across the sample and the resultant heating is reduced. In this work we describe the development of a magic angle spinning (MAS) solid state NMR probe utilizing a dual resonator. This dual resonator approach, referred to as “Low-E,” was originally developed to reduce heating in samples of mechanically aligned membranes. The study of inherently dilute systems, such as proteins in lipid bilayers, via MAS techniques requires large sample volumes at high field to obtain spectra with adequate signal-to-noise ratio under physiologically relevant conditions. With the Low-E approach, we are able to obtain homogeneous and sufficiently strong radiofrequency fields for both 1H and 13C frequencies in a 4 mm probe with a 1H frequency of 750 MHz. The performance of the probe using windowless dipolar recoupling sequences is demonstrated on model compounds as well as membrane embedded peptides. PMID:19138870
Jiang, Yi-Ming; Huang, Chen; Peng, Zhong; Han, Shao-Ling; Li, Wei-Guang; Zhu, Michael Xi; Xu, Tian-Le
2017-01-01
Tachyphylaxis of itch refers to a markedly reduced scratching response to consecutive exposures of a pruritogen, a process thought to protect against tissue damage by incessant scratching and to become disrupted in chronic itch. Here, we report that a strong stimulation of the Mas-related G-protein-coupled receptor C11 by its agonist, Ser-Leu-Ile-Gly-Arg-Leu-NH 2 (SL-NH 2 ) or bovine adrenal medulla 8-22 peptide, via subcutaneous injection in mice induces tachyphylaxis to the subsequent application of SL-NH 2 to the same site. Notably, co-application of acid and SL-NH 2 following the initial injection of the pruritogen alone counteracted itch tachyphylaxis by augmenting the scratching behaviors in wild-type but not in acid-sensing ion channel 3-null, animals. Using an activity-dependent silencing strategy, we identified that acid-sensing ion channel 3-mediated itch enhancement mainly occurred via the Mas-related G-protein-coupled receptor C11-responsive sensory neurons. Together, our results indicate that acid-sensing ion channel 3, activated by concomitant acid and certain pruritogens, constitute a novel signaling pathway that counteracts itch tachyphylaxis to successive pruritogenic stimulation, which likely contributes to chronic itch associated with tissue acidosis.
Jiang, Yi-Ming; Huang, Chen; Peng, Zhong; Han, Shao-Ling; Li, Wei-Guang; Zhu, Michael Xi; Xu, Tian-Le
2017-01-01
Tachyphylaxis of itch refers to a markedly reduced scratching response to consecutive exposures of a pruritogen, a process thought to protect against tissue damage by incessant scratching and to become disrupted in chronic itch. Here, we report that a strong stimulation of the Mas-related G-protein-coupled receptor C11 by its agonist, Ser-Leu-Ile-Gly-Arg-Leu-NH2 (SL-NH2) or bovine adrenal medulla 8-22 peptide, via subcutaneous injection in mice induces tachyphylaxis to the subsequent application of SL-NH2 to the same site. Notably, co-application of acid and SL-NH2 following the initial injection of the pruritogen alone counteracted itch tachyphylaxis by augmenting the scratching behaviors in wild-type but not in acid-sensing ion channel 3-null, animals. Using an activity-dependent silencing strategy, we identified that acid-sensing ion channel 3-mediated itch enhancement mainly occurred via the Mas-related G-protein-coupled receptor C11-responsive sensory neurons. Together, our results indicate that acid-sensing ion channel 3, activated by concomitant acid and certain pruritogens, constitute a novel signaling pathway that counteracts itch tachyphylaxis to successive pruritogenic stimulation, which likely contributes to chronic itch associated with tissue acidosis. PMID:28745101
ERIC Educational Resources Information Center
Berndt, Sandra; Ebben, Barbara; Kubinski, Eva; Sim, Grant; Liu, Kristin; Lazarus, Sheryl; Thurlow, Martha; Christian, Elizabeth
2011-01-01
Beginning in 2007, federal regulations to two major education laws gave state departments of education the option to develop an alternate assessment based on modified achievement standards (AA-MAS) for some students with disabilities. The regulations stated that the AA-MAS was intended for students who were being instructed in the grade-level…
A Quantum Approach to Multi-Agent Systems (MAS), Organizations, and Control
2003-06-01
interdependent interactions between individuals represented approximately as vocal harmonic I resonators. Then the growth rate of an organization fits ...A quantum approach to multi-agent systems (MAS), organizations , and control W.F. Lawless Paine College 1235 15th Street Augusta, GA 30901...AND SUBTITLE A quantum approach to multi-agent systems (MAS), organizations , and control 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT
Budak, Umit; Şengür, Abdulkadir; Guo, Yanhui; Akbulut, Yaman
2017-12-01
Microaneurysms (MAs) are known as early signs of diabetic-retinopathy which are called red lesions in color fundus images. Detection of MAs in fundus images needs highly skilled physicians or eye angiography. Eye angiography is an invasive and expensive procedure. Therefore, an automatic detection system to identify the MAs locations in fundus images is in demand. In this paper, we proposed a system to detect the MAs in colored fundus images. The proposed method composed of three stages. In the first stage, a series of pre-processing steps are used to make the input images more convenient for MAs detection. To this end, green channel decomposition, Gaussian filtering, median filtering, back ground determination, and subtraction operations are applied to input colored fundus images. After pre-processing, a candidate MAs extraction procedure is applied to detect potential regions. A five-stepped procedure is adopted to get the potential MA locations. Finally, deep convolutional neural network (DCNN) with reinforcement sample learning strategy is used to train the proposed system. The DCNN is trained with color image patches which are collected from ground-truth MA locations and non-MA locations. We conducted extensive experiments on ROC dataset to evaluate of our proposal. The results are encouraging.
Than, Aung; Leow, Melvin Khee-Shing; Chen, Peng
2013-05-31
Angiotensin II (AngII), a peptide hormone released by adipocytes, can be catabolized by adipose angiotensin-converting enzyme 2 (ACE2) to form Ang(1-7). Co-expression of AngII receptors (AT1 and AT2) and Ang(1-7) receptors (Mas) in adipocytes implies the autocrine regulation of the local angiotensin system upon adipocyte functions, through yet unknown interactive mechanisms. In the present study, we reveal the adipogenic effects of Ang(1-7) through activation of Mas receptor and its subtle interplays with the antiadipogenic AngII-AT1 signaling pathways. Specifically, in human and 3T3-L1 preadipocytes, Ang(1-7)-Mas signaling promotes adipogenesis via activation of PI3K/Akt and inhibition of MAPK kinase/ERK pathways, and Ang(1-7)-Mas antagonizes the antiadipogenic effect of AngII-AT1 by inhibiting the AngII-AT1-triggered MAPK kinase/ERK pathway. The autocrine regulation of the AngII/AT1-ACE2-Ang(1-7)/Mas axis upon adipogenesis has also been revealed. This study suggests the importance of the local regulation of the delicately balanced angiotensin system upon adipogenesis and its potential as a novel therapeutic target for obesity and related metabolic disorders.
A Population Genetics Model of Marker-Assisted Selection
Luo, Z. W.; Thompson, R.; Woolliams, J. A.
1997-01-01
A deterministic two-loci model was developed to predict genetic response to marker-assisted selection (MAS) in one generation and in multiple generations. Formulas were derived to relate linkage disequilibrium in a population to the proportion of additive genetic variance used by MAS, and in turn to an extra improvement in genetic response over phenotypic selection. Predictions of the response were compared to those predicted by using an infinite-loci model and the factors affecting efficiency of MAS were examined. Theoretical analyses of the present study revealed the nonlinearity between the selection intensity and genetic response in MAS. In addition to the heritability of the trait and the proportion of the marker-associated genetic variance, the frequencies of the selectively favorable alleles at the two loci, one marker and one quantitative trait locus, were found to play an important role in determining both the short- and long-term efficiencies of MAS. The evolution of linkage disequilibrium and thus the genetic response over several generations were predicted theoretically and examined by simulation. MAS dissipated the disequilibrium more quickly than drift alone. In some cases studied, the rate of dissipation was as large as that to be expected in the circumstance where the true recombination fraction was increased by three times and selection was absent. PMID:9215918
The demands and benefits of ergonomics in Sri Lankan apparel industry: A case study at MAS holdings.
Abeysekera, John; Illankoon, Prasanna
2016-10-17
Apparel exports bring in sizeable foreign income to Sri Lanka. To protect and promote this industry is a paramount need. This can be carried out by applying Human Factors/Ergonomics (HFE) which has proved to control negative effects at work places. This paper reports a case study which describes the demands and benefits of HFE in MAS Holdings which owns a large share of the apparel industry in Sri Lanka. The study consisted of walk through observation survey, a questionnaire survey and ergonomic work place analysis followed by a training programme to selected employees in three companies. Positive responses to questionnaires revealed good ergonomic practices in the work places surveyed. Ergonomically unfit chairs and potential hazards e.g. exposure to noise and hot environment were detected. It is seen that MAS have introduced strategies originated by Toyota Production System viz. 5S, Kaizen, six sigma etc., which are in fact ergonomic methods. A progressive project MAS boast of viz. 'MAS Operating System' (MOS) empowers training and development to employees. MAS Holdings has adequately realized the benefits of applying HFE as evident by the number of awards received. Relevant companies were advised to take appropriate corrective measures to control the potential hazards.
Validation of a Low Dose Simulation Technique for Computed Tomography Images
Muenzel, Daniela; Koehler, Thomas; Brown, Kevin; Žabić, Stanislav; Fingerle, Alexander A.; Waldt, Simone; Bendik, Edgar; Zahel, Tina; Schneider, Armin; Dobritz, Martin; Rummeny, Ernst J.; Noël, Peter B.
2014-01-01
Purpose Evaluation of a new software tool for generation of simulated low-dose computed tomography (CT) images from an original higher dose scan. Materials and Methods Original CT scan data (100 mAs, 80 mAs, 60 mAs, 40 mAs, 20 mAs, 10 mAs; 100 kV) of a swine were acquired (approved by the regional governmental commission for animal protection). Simulations of CT acquisition with a lower dose (simulated 10–80 mAs) were calculated using a low-dose simulation algorithm. The simulations were compared to the originals of the same dose level with regard to density values and image noise. Four radiologists assessed the realistic visual appearance of the simulated images. Results Image characteristics of simulated low dose scans were similar to the originals. Mean overall discrepancy of image noise and CT values was −1.2% (range −9% to 3.2%) and −0.2% (range −8.2% to 3.2%), respectively, p>0.05. Confidence intervals of discrepancies ranged between 0.9–10.2 HU (noise) and 1.9–13.4 HU (CT values), without significant differences (p>0.05). Subjective observer evaluation of image appearance showed no visually detectable difference. Conclusion Simulated low dose images showed excellent agreement with the originals concerning image noise, CT density values, and subjective assessment of the visual appearance of the simulated images. An authentic low-dose simulation opens up opportunity with regard to staff education, protocol optimization and introduction of new techniques. PMID:25247422
Yanagimachi, Masakatsu; Naruto, Takuya; Miyamae, Takako; Hara, Takuma; Kikuchi, Masako; Hara, Ryoki; Imagawa, Tomoyuki; Mori, Masaaki; Sato, Hidenori; Goto, Hiroaki; Yokota, Shumpei
2011-04-01
Systemic-onset juvenile idiopathic arthritis (systemic JIA) and macrophage activation syndrome (MAS), the most devastating complication of systemic JIA, are characterized by abnormal levels of proinflammatory cytokines. Interferon regulatory factor 5 (IRF5) is a member of the IRF family of transcription factors, and acts as a master transcription factor in the activation of genes encoding proinflammatory cytokines. Polymorphisms in the IRF5 gene have been associated with susceptibility to autoimmune diseases such as systemic lupus erythematosus (SLE) and rheumatoid arthritis. Our aim was to assess associations of IRF5 gene polymorphisms with susceptibility to systemic JIA and MAS. Three IRF5 single-nucleotide polymorphisms (rs729302, rs2004640, and rs2280714) were genotyped using TaqMan assays in 81 patients with systemic JIA (33 with MAS, 48 without) and 190 controls. There were no associations of the IRF5 gene polymorphisms or haplotypes under study with susceptibility to systemic JIA. There was a significant association of the rs2004640 T allele with MAS susceptibility (OR 4.11; 95% CI 1.84, 9.16; p = 0.001). The IRF5 haplotype (rs729302 A, rs2004640 T, and rs2280714 T), which was reported as conferring an increased risk of SLE, was significantly associated with MAS susceptibility in patients with systemic JIA (OR 4.61; 95% CI 1.73, 12.3; p < 0.001). IRF5 gene polymorphism is a genetic factor influencing susceptibility to MAS in patients with systemic JIA, and IRF5 contributes to the pathogenesis of MAS in these patients.
NASA Astrophysics Data System (ADS)
Tecza, Matthias; Thatte, Niranjan; Clarke, Fraser; Lynn, James; Freeman, David; Roberts, Jennifer; Dekany, Richard
2012-09-01
When commissioned in November 2008 at the Palomar 200 inch Hale Telescope, the Oxford SWIFT I and z band integral field spectrograph, fed by the adaptive optics system PALAO, provided a wide (3×) range of spatial resolutions: three plate scales of 235 mas, 160 mas, and 80 mas per spaxel over a contiguous field-of-view of 89×44 pixels. Depending on observing conditions and guide star brightness we can choose a seeing limited scale of 235 mas per spaxel, or 160 mas and 80 mas per spaxel for very bright guide star AO with substantial increase of enclosed energy. Over the last two years PALAO was upgraded to PALM-3000: an extreme, high-order adaptive optics system with two deformable mirrors with more than 3000 actuators, promising diffraction limited performance in SWIFT's wavelength range. In order to take advantage of this increased spatial resolution we upgraded SWIFT with new pre-optics allowing us to spatially Nyquist sample the diffraction limited PALM-3000 point spread function with 16 mas resolution, reducing the spaxel scale by another factor of 5×. We designed, manufactured, integrated and tested the new pre-optics in the first half of 2011 and commissioned it in December 2011. Here we present the opto-mechanical design and assembly of the new scale changing optics, as well as laboratory and on-sky commissioning results. In optimal observing conditions we achieve substantial Strehl ratios, delivering the near diffraction limited spatial resolution in the I and z bands.
Abuohashish, Hatem M; Ahmed, Mohammed M; Sabry, Dina; Khattab, Mahmoud M; Al-Rejaie, Salim S
2017-05-23
The local and systemic renin angiotensin system (RAS) influences the skeletal system micro-structure and metabolism. Studies suggested angiotensin 1-7 (Ang(1-7)) as the beneficial RAS molecule via Mas receptor activation. This study examines the function of Ang(1-7) in bone micro-architecture and metabolism in an ovariectomized (OVX) rodent model of osteoporosis. OVX rats showed structural and bone metabolic degeneration in parallel with suppressed expressions of the angiotensin converting enzyme-2 (ACE-2)/Ang(1-7)/Mas components. The infusion of Ang(1-7) markedly alleviated the altered bone metabolism and significantly enhanced both trabecular (metaphyseal) and cortical (metaphyseal-diaphyseal) morphometry. Urinary and bones minerals were also improved in OVX rats by Ang(1-7). The infusion of the heptapeptide enhanced ACE-2/Mas receptor expressions, while down-regulated AngII, ACE, and AngII type-1 receptor (AT1R) in OVX animals. Moreover, Ang(1-7) markedly improved osteoprotegerin (OPG) and lowered receptor activator NF-κB ligand (RANKL) expressions. The defensive properties of Ang(1-7) on bone metabolism, structure and minerals were considerably eradicated after blockage of Mas receptor with A-779. Ang(1-7)-induced up-regulated ACE-2/Ang(1-7)/Mas cascade and OPG expressions were abolished and the expressions of ACE/AngII/AT1R and RANKL were provoked by A-779. These findings shows for the first time the novel valuable therapeutic role of Ang(1-7) on bone health and metabolism through the ACE-2/Mas cascade.
Cho, Hyun-Woo; Hwang, Eui-Hyoung; Lim, Byungmook; Heo, Kwang-Ho; Liu, Jian-Ping; Tsutani, Kiichiro; Lee, Myeong Soo; Shin, Byung-Cheul
2014-01-01
The aims of this study were to investigate whether there is a gap between evidence of traditional medicine (TM) interventions in East-Asian countries from the current Clinical Practice Guidelines (CPGs) and evidence from current systematic reviews and meta-analyses (SR-MAs) and to analyze the impact of this gap on present CPGs. We examined 5 representative TM interventions in the health care systems of East-Asian countries. We searched seven relevant databases for CPGs to identify whether core CPGs included evidence of TM interventions, and we searched 11 databases for SR-MAs to re-evaluate current evidence on TM interventions. We then compared the gap between the evidence from CPGs and SR-MAs. Thirteen CPGs and 22 SR-MAs met our inclusion criteria. Of the 13 CPGs, 7 CPGs (54%) mentioned TM interventions, and all were for acupuncture (only one was for both acupuncture and acupressure). However, the CPGs did not recommend acupuncture (or acupressure). Of 22 SR-MAs, 16 were for acupuncture, 5 for manual therapy, 1 for cupping, and none for moxibustion and herbal medicine. Comparing the evidence from CPGs and SR-MAs, an underestimation or omission of evidence for acupuncture, cupping, and manual therapy in current CPGs was detected. Thus, applying the results from the SR-MAs, we moderately recommend acupuncture for chronic LBP, but we inconclusively recommend acupuncture for (sub)acute LBP due to the limited current evidence. Furthermore, we weakly recommend cupping and manual therapy for both (sub)acute and chronic LBP. We cannot provide recommendations for moxibustion and herbal medicine due to a lack of evidence. The current CPGs did not fully reflect the evidence for TM interventions. As relevant studies such as SR-MAs are conducted and evidence increases, the current evidence on acupuncture, cupping, and manual therapy should be rigorously considered in the process of developing or updating the CPG system.
Zhuang, Xiahai; Bai, Wenjia; Song, Jingjing; Zhan, Songhua; Qian, Xiaohua; Shi, Wenzhe; Lian, Yanyun; Rueckert, Daniel
2015-07-01
Cardiac computed tomography (CT) is widely used in clinical diagnosis of cardiovascular diseases. Whole heart segmentation (WHS) plays a vital role in developing new clinical applications of cardiac CT. However, the shape and appearance of the heart can vary greatly across different scans, making the automatic segmentation particularly challenging. The objective of this work is to develop and evaluate a multiatlas segmentation (MAS) scheme using a new atlas ranking and selection algorithm for automatic WHS of CT data. Research on different MAS strategies and their influence on WHS performance are limited. This work provides a detailed comparison study evaluating the impacts of label fusion, atlas ranking, and sizes of the atlas database on the segmentation performance. Atlases in a database were registered to the target image using a hierarchical registration scheme specifically designed for cardiac images. A subset of the atlases were selected for label fusion, according to the authors' proposed atlas ranking criterion which evaluated the performance of each atlas by computing the conditional entropy of the target image given the propagated atlas labeling. Joint label fusion was used to combine multiple label estimates to obtain the final segmentation. The authors used 30 clinical cardiac CT angiography (CTA) images to evaluate the proposed MAS scheme and to investigate different segmentation strategies. The mean WHS Dice score of the proposed MAS method was 0.918 ± 0.021, and the mean runtime for one case was 13.2 min on a workstation. This MAS scheme using joint label fusion generated significantly better Dice scores than the other label fusion strategies, including majority voting (0.901 ± 0.276, p < 0.01), locally weighted voting (0.905 ± 0.0247, p < 0.01), and probabilistic patch-based fusion (0.909 ± 0.0249, p < 0.01). In the atlas ranking study, the proposed criterion based on conditional entropy yielded a performance curve with higher WHS Dice scores compared to the conventional schemes (p < 0.03). In the atlas database study, the authors showed that the MAS using larger atlas databases generated better performance curves than the MAS using smaller ones, indicating larger atlas databases could produce more accurate segmentation. The authors have developed a new MAS framework for automatic WHS of CTA and investigated alternative implementations of MAS. With the proposed atlas ranking algorithm and joint label fusion, the MAS scheme is able to generate accurate segmentation within practically acceptable computation time. This method can be useful for the development of new clinical applications of cardiac CT.
Macrophage Activation Syndrome.
Ravelli, Angelo; Davì, Sergio; Minoia, Francesca; Martini, Alberto; Cron, Randy Q
2015-10-01
Macrophage activation syndrome (MAS) is a potentially life-threatening complication of rheumatic disorders that occurs most commonly in systemic juvenile idiopathic arthritis. In recent years, there have been several advances in the understanding of the pathophysiology of MAS. Furthermore, new classification criteria have been developed. Although the place of cytokine blockers in the management of MAS is still unclear, interleukin-1 inhibitors represent a promising adjunctive therapy, particularly in refractory cases. Copyright © 2015 Elsevier Inc. All rights reserved.
Arzumanov, Sergei S; Gabrienko, Anton A; Freude, Dieter; Stepanov, Alexander G
2009-04-01
Ethane conversion into aromatic hydrocarbons over Zn-modified zeolite BEA has been analyzed by high-temperature MAS NMR spectroscopy. Information about intermediates (Zn-ethyl species) and reaction products (mainly toluene and methane), which were formed under the conditions of a batch reactor, was obtained by (13)C MAS NMR. Kinetics of the reaction, which was monitored by (1)H MAS NMR in situ at the temperature of 573K, provided information about the reaction mechanism. Simulation of the experimental kinetics within the frames of the possible kinetic schemes of the reaction demonstrates that a large amount of methane evolved under ethane aromatization arises from the stage of direct ethane hydrogenolysis.
Multi Agent Systems with Symbiotic Learning and Evolution using GNP
NASA Astrophysics Data System (ADS)
Eguchi, Toru; Hirasawa, Kotaro; Hu, Jinglu; Murata, Junichi
Recently, various attempts relevant to Multi Agent Systems (MAS) which is one of the most promising systems based on Distributed Artificial Intelligence have been studied to control large and complicated systems efficiently. In these trends of MAS, Multi Agent Systems with Symbiotic Learning and Evolution named Masbiole has been proposed. In Masbiole, symbiotic phenomena among creatures are considered in the process of learning and evolution of MAS. So we can expect more flexible and sophisticated solutions than conventional MAS. In this paper, we apply Masbiole to Iterative Prisoner’s Dilemma Games (IPD Games) using Genetic Network Programming (GNP) which is a newly developed evolutionary computation method for constituting agents. Some characteristics of Masbiole using GNP in IPD Games are clarified.
2011-05-01
for the research in the next year. The aims in the next year include further develop- ment of the prior image- based , narrowly collimated CBCT imaging...further investigation planned for the next year. 5 BODY 1 Research Accomplishments 1.1 Implement narrow beam collimation for CBCT ROI imaging I have...noise level to mimic different mAs used in clinical and research modes of the CBCT system. Based upon experiences with the numerical phantom, I designed
Volumetric breast density measurement: sensitivity analysis of a relative physics approach
Lau, Susie; Abdul Aziz, Yang Faridah
2016-01-01
Objective: To investigate the sensitivity and robustness of a volumetric breast density (VBD) measurement system to errors in the imaging physics parameters including compressed breast thickness (CBT), tube voltage (kVp), filter thickness, tube current-exposure time product (mAs), detector gain, detector offset and image noise. Methods: 3317 raw digital mammograms were processed with Volpara® (Matakina Technology Ltd, Wellington, New Zealand) to obtain fibroglandular tissue volume (FGV), breast volume (BV) and VBD. Errors in parameters including CBT, kVp, filter thickness and mAs were simulated by varying them in the Digital Imaging and Communications in Medicine (DICOM) tags of the images up to ±10% of the original values. Errors in detector gain and offset were simulated by varying them in the Volpara configuration file up to ±10% from their default values. For image noise, Gaussian noise was generated and introduced into the original images. Results: Errors in filter thickness, mAs, detector gain and offset had limited effects on FGV, BV and VBD. Significant effects in VBD were observed when CBT, kVp, detector offset and image noise were varied (p < 0.0001). Maximum shifts in the mean (1.2%) and median (1.1%) VBD of the study population occurred when CBT was varied. Conclusion: Volpara was robust to expected clinical variations, with errors in most investigated parameters giving limited changes in results, although extreme variations in CBT and kVp could lead to greater errors. Advances in knowledge: Despite Volpara's robustness, rigorous quality control is essential to keep the parameter errors within reasonable bounds. Volpara appears robust within those bounds, albeit for more advanced applications such as tracking density change over time, it remains to be seen how accurate the measures need to be. PMID:27452264
Exploiting Wild Relatives for Genomics-assisted Breeding of Perennial Crops
Migicovsky, Zoë; Myles, Sean
2017-01-01
Perennial crops are vital contributors to global food production and nutrition. However, the breeding of new perennial crops is an expensive and time-consuming process due to the large size and lengthy juvenile phase of many species. Genomics provides a valuable tool for improving the efficiency of breeding by allowing progeny possessing a trait of interest to be selected at the seed or seedling stage through marker-assisted selection (MAS). The benefits of MAS to a breeder are greatest when the targeted species takes a long time to reach maturity and is expensive to grow and maintain. Thus, MAS holds particular promise in perennials since they are often costly and time-consuming to grow to maturity and evaluate. Well-characterized germplasm that breeders can tap into for improving perennials is often limited in genetic diversity. Wild relatives are a largely untapped source of desirable traits including disease resistance, fruit quality, and rootstock characteristics. This review focuses on the use of genomics-assisted breeding in perennials, especially as it relates to the introgression of useful traits from wild relatives. The identification of genetic markers predictive of beneficial phenotypes derived from wild relatives is hampered by genomic tools designed for domesticated species that are often ill-suited for use in wild relatives. There is therefore an urgent need for better genomic resources from wild relatives. A further barrier to exploiting wild diversity through genomics is the phenotyping bottleneck: well-powered genetic mapping requires accurate and cost-effective characterization of large collections of diverse wild germplasm. While genomics will always be used in combination with traditional breeding methods, it is a powerful tool for accelerating the speed and reducing the costs of breeding while harvesting the potential of wild relatives for improving perennial crops. PMID:28421095
Exploiting Wild Relatives for Genomics-assisted Breeding of Perennial Crops.
Migicovsky, Zoë; Myles, Sean
2017-01-01
Perennial crops are vital contributors to global food production and nutrition. However, the breeding of new perennial crops is an expensive and time-consuming process due to the large size and lengthy juvenile phase of many species. Genomics provides a valuable tool for improving the efficiency of breeding by allowing progeny possessing a trait of interest to be selected at the seed or seedling stage through marker-assisted selection (MAS). The benefits of MAS to a breeder are greatest when the targeted species takes a long time to reach maturity and is expensive to grow and maintain. Thus, MAS holds particular promise in perennials since they are often costly and time-consuming to grow to maturity and evaluate. Well-characterized germplasm that breeders can tap into for improving perennials is often limited in genetic diversity. Wild relatives are a largely untapped source of desirable traits including disease resistance, fruit quality, and rootstock characteristics. This review focuses on the use of genomics-assisted breeding in perennials, especially as it relates to the introgression of useful traits from wild relatives. The identification of genetic markers predictive of beneficial phenotypes derived from wild relatives is hampered by genomic tools designed for domesticated species that are often ill-suited for use in wild relatives. There is therefore an urgent need for better genomic resources from wild relatives. A further barrier to exploiting wild diversity through genomics is the phenotyping bottleneck: well-powered genetic mapping requires accurate and cost-effective characterization of large collections of diverse wild germplasm. While genomics will always be used in combination with traditional breeding methods, it is a powerful tool for accelerating the speed and reducing the costs of breeding while harvesting the potential of wild relatives for improving perennial crops.
Volumetric breast density measurement: sensitivity analysis of a relative physics approach.
Lau, Susie; Ng, Kwan Hoong; Abdul Aziz, Yang Faridah
2016-10-01
To investigate the sensitivity and robustness of a volumetric breast density (VBD) measurement system to errors in the imaging physics parameters including compressed breast thickness (CBT), tube voltage (kVp), filter thickness, tube current-exposure time product (mAs), detector gain, detector offset and image noise. 3317 raw digital mammograms were processed with Volpara(®) (Matakina Technology Ltd, Wellington, New Zealand) to obtain fibroglandular tissue volume (FGV), breast volume (BV) and VBD. Errors in parameters including CBT, kVp, filter thickness and mAs were simulated by varying them in the Digital Imaging and Communications in Medicine (DICOM) tags of the images up to ±10% of the original values. Errors in detector gain and offset were simulated by varying them in the Volpara configuration file up to ±10% from their default values. For image noise, Gaussian noise was generated and introduced into the original images. Errors in filter thickness, mAs, detector gain and offset had limited effects on FGV, BV and VBD. Significant effects in VBD were observed when CBT, kVp, detector offset and image noise were varied (p < 0.0001). Maximum shifts in the mean (1.2%) and median (1.1%) VBD of the study population occurred when CBT was varied. Volpara was robust to expected clinical variations, with errors in most investigated parameters giving limited changes in results, although extreme variations in CBT and kVp could lead to greater errors. Despite Volpara's robustness, rigorous quality control is essential to keep the parameter errors within reasonable bounds. Volpara appears robust within those bounds, albeit for more advanced applications such as tracking density change over time, it remains to be seen how accurate the measures need to be.
Water speciation in sodium silicate glasses (quenched melts): A comprehensive NMR study
NASA Astrophysics Data System (ADS)
Xue, X.; Kanzaki, M.; Eguchi, J.
2012-12-01
Dissolution mechanism of water is an important factor governing how the dissolved water affects the physical and thermodynamic properties of silicate melts and glasses. Our previous studies have demonstrated that 1H MAS NMR in combination with 29Si-1H and 27Al-1H double-resonance NMR experiments is an effective approach for unambiguously differentiating and quantifying different water species in quenched silicate melts (glasses). Several contrasting dissolution mechanisms have been revealed depending on the melt composition: for relatively polymerized melts, the formation of SiOH/AlOH species (plus molecular H2O) and depolymerization of the network structure dominate; whereas for depolymerized Ca-Mg silicate melts, free OH (e.g. MgOH) become increasingly important (cf. [1]). The proportion of free OH species has been shown to decrease with both increasing melt polymerization (silica content) and decreasing field strength of the network modifying cations (from Mg to Ca). Our previous 1H and 29Si MAS NMR results for hydrous Na silicate glasses of limited compositions (Na2Si4O9 and Na2Si2O5) were consistent with negligible free OH (NaOH) species and depolymerizing effect of water dissolution [2]. On the other hand, there were also other studies that proposed the presence of significant NaOH species in hydrous glasses near the Na2Si2O5 composition. The purpose of this study is apply the approach of combined 1H MAS NMR and double-resonance (29Si-1H and 23Na-1H) NMR to gain unambiguous evidence for the OH speciation in Na silicate glasses (melts) as a function of composition. Hydrous Na silicate glasses containing mostly ≤ 1 wt% H2O for a range of Na/Si ratios from 0.33 to 1.33 have been synthesized by rapidly quenching melts either at 0.2 GPa using an internally heated gas pressure vessel or at 1 GPa using a piston cylinder high-pressure apparatus. NMR spectra have been acquired using a 9.4 T Varian Unity-Inova spectrometer. The 29Si and 1H chemical shifts are reported relative to TMS. The 1H MAS NMR spectra show broad peaks covering a chemical shift range of 1 to 17 ppm, with peak maxima near 4 and 15 ppm for more Si-rich compositions and near 12 ppm for less Si-rich compositions. The 1H-29Si-1H and 23Na-1H cross-polarization (CP) MAS NMR spectra for all the hydrous Na silicate glasses suggest negligible NaOH species, which, if present, should show enhanced relative intensity with 23Na-1H CP and the opposite with 1H-29Si-1H CP. All the observed 1H NMR intensities can be attributed to SiOH species of a range of hydrogen-bonding distances, plus a small amount of molecular H2O for higher water-content samples that contribute to intensities around 6 ppm. In conclusion, our combined 1H MAS NMR and double-resonance (1H-29Si-1H and 23Na-1H CP) MAS NMR study on Na silicate glasses of a range of Na/Si ratios has confirmed that water dissolves predominantly as SiOH and molecular H2O species in Na silicate melts (glasses), consistent with the trend predicted from studies on the Ca-Mg silicate system [1,2]. References:[1] Xue, X. Y.; Kanzaki, M. J. Am. Ceram. Soc. 2009, 92, 2803-2830. [2] Xue, X. Y.; Kanzaki, M. Geochim. Cosmochim. Acta 2004, 68, 5027-5057.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gill, K; Aldoohan, S; Collier, J
Purpose: Study image optimization and radiation dose reduction in pediatric shunt CT scanning protocol through the use of different beam-hardening filters Methods: A 64-slice CT scanner at OU Childrens Hospital has been used to evaluate CT image contrast-to-noise ratio (CNR) and measure effective-doses based on the concept of CT dose index (CTDIvol) using the pediatric head shunt scanning protocol. The routine axial pediatric head shunt scanning protocol that has been optimized for the intrinsic x-ray tube filter has been used to evaluate CNR by acquiring images using the ACR approved CT-phantom and radiation dose CTphantom, which was used to measuremore » CTDIvol. These results were set as reference points to study and evaluate the effects of adding different filtering materials (i.e. Tungsten, Tantalum, Titanium, Nickel and Copper filters) to the existing filter on image quality and radiation dose. To ensure optimal image quality, the scanner routine air calibration was run for each added filter. The image CNR was evaluated for different kVps and wide range of mAs values using above mentioned beam-hardening filters. These scanning protocols were run under axial as well as under helical techniques. The CTDIvol and the effective-dose were measured and calculated for all scanning protocols and added filtration, including the intrinsic x-ray tube filter. Results: Beam-hardening filter shapes energy spectrum, which reduces the dose by 27%. No noticeable changes in image low contrast detectability Conclusion: Effective-dose is very much dependent on the CTDIVol, which is further very much dependent on beam-hardening filters. Substantial reduction in effective-dose is realized using beam-hardening filters as compare to the intrinsic filter. This phantom study showed that significant radiation dose reduction could be achieved in CT pediatric shunt scanning protocols without compromising in diagnostic value of image quality.« less
Notzon, Daniel P.; Mariani, John J.; Pavlicova, Martina; Glass, Andrew; Mahony, Amy L.; Brooks, Daniel J.; Grabowski, John; Levin, Frances R.
2017-01-01
Background and Objectives The prevalence of ADHD is greater in substance use disorders than the general population, and ADHD and substance use disorders share neurobiological features such as dysregulation of reward circuitry. We tested the hypothesis that stimulants would decrease marijuana use in a randomized controlled trial of extended release mixed amphetamine salts (MAS-XR) for treatment of co-occurring ADHD and cocaine use disorders. Methods Marijuana users were defined as participants reporting use in the 30 days before study initiation, collected with timeline follow-back. The original 14-week trial utilized a 3-arm randomized design, comparing placebo, MAS-XR 60 mg, and MAS-XR 80 mg. For this analysis, both MAS-XR groups were combined, leaving n = 20 in the placebo group and n = 37 in the MAS-XR group. The primary outcome was proportion of subjects reporting any marijuana use per study week. Comparisons between groups were made using a logistic mixed effects model incorporating multiple predictors and modeling time-by-treatment interactions. Results There were no significant baseline differences in marijuana use frequency and quantity. There was a significant decrease in the proportion of participants using marijuana over time in the MAS-XR group, but no difference in the proportion of marijuana-use days over time. Discussion and Conclusions Treatment of ADHD and comorbid cocaine use disorders with MAS-XR is associated with increased weekly abstinence from marijuana but not with a decrease in the proportion of marijuana using days per week. Scientific Significance Stimulant treatment of ADHD and cocaine use disorders may diminish co-occurring cannabis use. PMID:28051838
Nachappa, Somanna Ajjamada; Neelambike, Sumana M; Amruthavalli, Chokkanna; Ramachandra, Nallur B
2018-05-01
Diagnosis of drug-resistant tuberculosis predominantly relies on culture-based drug susceptibility testing, which take weeks to produce a result and a more time-efficient alternative method is multiplex allele-specific PCR (MAS-PCR). Also, understanding the role of mutations in causing resistance helps better drug designing. To evaluate the ability of MAS-PCR in the detection of drug resistance and to understand the mechanism of interaction of drugs with mutant proteins in Mycobacterium tuberculosis. Detection of drug-resistant mutations using MAS-PCR and validation through DNA sequencing. MAS-PCR targeted five loci on three genes, katG 315 and inhA -15 for the drug isoniazid (INH), and rpoB 516, 526, and 531 for rifampicin (RIF). Furthermore, the sequence data were analyzed to study the effect on interaction of the anti-TB drug molecule with the target protein using in silico docking. We identified drug-resistant mutations in 8 out of 114 isolates with 2 of them as multidrug-resistant TB using MAS-PCR. DNA sequencing confirmed only six of these, recording a sensitivity of 85.7% and specificity of 99.3% for MAS-PCR. Molecular docking showed estimated free energy of binding (ΔG) being higher for RIF binding with RpoB S531L mutant. Codon 315 in KatG does not directly interact with INH but blocks the drug access to active site. We propose DNA sequencing-based drug resistance detection for TB, which is more accurate than MAS-PCR. Understanding the action of resistant mutations in disrupting the normal drug-protein interaction aids in designing effective drug alternatives.
Notzon, Daniel P; Mariani, John J; Pavlicova, Martina; Glass, Andrew; Mahony, Amy L; Brooks, Daniel J; Grabowski, John; Levin, Frances R
2016-12-01
The prevalence of ADHD is greater in substance use disorders than the general population, and ADHD and substance use disorders share neurobiological features such as dysregulation of reward circuitry. We tested the hypothesis that stimulants would decrease marijuana use in a randomized controlled trial of extended release mixed amphetamine salts (MAS-XR) for treatment of co-occurring ADHD and cocaine use disorders. Marijuana users were defined as participants reporting use in the 30 days before study initiation, collected with timeline follow-back. The original 14-week trial utilized a 3-arm randomized design, comparing placebo, MAS-XR 60 mg, and MAS-XR 80 mg. For this analysis, both MAS-XR groups were combined, leaving n = 20 in the placebo group and n = 37 in the MAS-XR group. The primary outcome was proportion of subjects reporting any marijuana use per study week. Comparisons between groups were made using a logistic mixed effects model incorporating multiple predictors and modeling time-by-treatment interactions. There were no significant baseline differences in marijuana use frequency and quantity. There was a significant decrease in the proportion of participants using marijuana over time in the MAS-XR group, but no difference in the proportion of marijuana-use days over time. Treatment of ADHD and comorbid cocaine use disorders with MAS-XR is associated with increased weekly abstinence from marijuana but not with a decrease in the proportion of marijuana using days per week. Stimulant treatment of ADHD and cocaine use disorders may diminish co-occurring cannabis use. (Am J Addict 2016;25:666-672). © 2016 American Academy of Addiction Psychiatry.
Choi, Ji Soo; Baek, Hyeon-Man; Kim, Suhkmann; Kim, Min Jung; Youk, Ji Hyun; Moon, Hee Jung; Kim, Eun-Kyung; Han, Kyung Hwa; Kim, Dong-hyun; Kim, Seung Il; Koo, Ja Seung
2012-01-01
The purpose of this study was to examine the correlation between high-resolution magic angle spinning (HR-MAS) magnetic resonance (MR) spectroscopy using core needle biopsy (CNB) specimens and histologic prognostic factors currently used in breast cancer patients. After institutional review board approval and informed consent were obtained for this study, CNB specimens were collected from 36 malignant lesions in 34 patients. Concentrations and metabolic ratios of various choline metabolites were estimated by HR-MAS MR spectroscopy using CNB specimens. HR-MAS spectroscopic values were compared according to histopathologic variables [tumor size, lymph node metastasis, histologic grade, status of estrogens receptor (ER), progesterone receptor (PR), HER2 (a receptor for human epidermal growth factor), and Ki-67, and triple negativity]. Multivariate analysis was performed with Orthogonal Projections to Latent Structure-Discriminant Analysis (OPLS-DA). HR-MAS MR spectroscopy quantified and discriminated choline metabolites in all CNB specimens of the 36 breast cancers. Several metabolite markers [free choline (Cho), phosphocholine (PC), creatine (Cr), taurine, myo-inositol, scyllo-inositol, total choline (tCho), glycine, Cho/Cr, tCho/Cr, PC/Cr] on HR-MAS MR spectroscopy were found to correlate with histologic prognostic factors [ER, PR, HER2, histologic grade, triple negativity, Ki-67, poor prognosis]. OPLS-DA multivariate models were generally able to discriminate the status of histologic prognostic factors (ER, PR, HER2, Ki-67) and prognosis groups. Our study suggests that HR-MAS MR spectroscopy using CNB specimens can predict tumor aggressiveness prior to surgery in breast cancer patients. In addition, it may be helpful in the detection of reliable markers for breast cancer characterization. PMID:23272149
,
1997-01-01
Data bases are essential for modern scientific research. The new and exciting work being done in the Mineral Resource Program in the U.S. Geological Survey (USGS) usually begins with the question, "Where are the known deposits?" A mineral-resource data base containing this type of information and more can be useful not just to USGS scientists, but to anyone who needs such data. Users of the data bases from outside the USGS include mining and exploration companies, environmental groups, academia, other Federal Agencies, and the general public. At present, the USGS has two large mineral-resource data bases, MRDS (Mineral Resource Data System) and MAS (Minerals Availability System). MRDS was built and is mamtained by the USGS, and MAS was built and maintained by the Bureau of Mines. In 1996, after the Bureau was abolished, MAS was transferred to the USGS. The two data bases were compiled for different purposes and contain very different mformation. For instance, MAS contains information on costs, details of mining methods, and feasibility studies. MRDS has mineralogical and geologic data that are not contained in MAS. Because they are both mineral-resource data bases, however, they contain some information in common, such as location, name(s) of sites, and commodities present. Both data bases are international in scope, and both are quite large. MRDS contains over 110,000 records, while MAS has over 220,000. One reason that MAS has more records is that it contains information on smelters, mill sites, and fossil fuel sites, as well as mineral- resource sites. The USGS is working to combine the information in both data bases. This is a large undertaking that will require some years to complete. In the interim, information from both data bases will still be available
NASA Technical Reports Server (NTRS)
Gallagher, K. M.; Fadel, P. J.; Stromstad, M.; Ide, K.; Smith, S. A.; Querry, R. G.; Raven, P. B.; Secher, N. H.
2001-01-01
1. This investigation was designed to determine the contribution of the exercise pressor reflex to the resetting of the carotid baroreflex during exercise. 2. Ten subjects performed 3.5 min of static one-legged exercise (20 % maximal voluntary contraction) and 7 min dynamic cycling (20 % maximal oxygen uptake) under two conditions: control (no intervention) and with the application of medical anti-shock (MAS) trousers inflated to 100 mmHg (to activate the exercise pressor reflex). Carotid baroreflex function was determined at rest and during exercise using a rapid neck pressure/neck suction technique. 3. During exercise, the application of MAS trousers (MAS condition) increased mean arterial pressure (MAP), plasma noradrenaline concentration (dynamic exercise only) and perceived exertion (dynamic exercise only) when compared to control (P < 0.05). No effect of the MAS condition was evident at rest. The MAS condition had no effect on heart rate (HR), plasma lactate and adrenaline concentrations or oxygen uptake at rest and during exercise. The carotid baroreflex stimulus-response curve was reset upward on the response arm and rightward to a higher operating pressure by control exercise without alterations in gain. Activation of the exercise pressor reflex by MAS trousers further reset carotid baroreflex control of MAP, as indicated by the upward and rightward relocation of the curve. However, carotid baroreflex control of HR was only shifted rightward to higher operating pressures by MAS trousers. The sensitivity of the carotid baroreflex was unaltered by exercise pressor reflex activation. 4. These findings suggest that during dynamic and static exercise the exercise pressor reflex is capable of actively resetting carotid baroreflex control of mean arterial pressure; however, it would appear only to modulate carotid baroreflex control of heart rate.
Mental Health Communications Skills Training for Medical Assistants in Pediatric Primary Care
Brown, Jonathan D.; Wissow, Lawrence S.; Cook, Benjamin L.; Longway, Shaina; Caffery, Emily; Pefaure, Chris
2012-01-01
Paraprofessional medical assistants (MAs) could help to promote pediatric primary care as a source of mental health services, particularly among patient populations who receive disparate mental health care. This project piloted a brief training to enhance the ability of MAs to have therapeutic encounters with Latino families who have mental health concerns in pediatric primary care. The evaluation of the pilot found that MAs were able to master most of the skills taught during the training, which improved their ability to have patient-centered encounters with families during standardized patient visits coded with the Roter Interaction Analysis System. Parents interviewed one and six months following the training were more than twice as willing as parents interviewed one month before the training to discuss mental health concerns with MAs and they had better perceptions of their interactions with MAs (all p < 0.01) even after controlling for a range of patient and visit characteristics. Before training, 10.2% of parents discussed a mental health concern with the MA but not the physician; this never happened six months after training. This pilot provides preliminary evidence that training MAs holds potential to supplement other educational and organizational interventions aimed at improving mental health services in pediatric primary care but further research is necessary to test this type of training in other settings and among different patient populations. PMID:23070564
Perceived Job Stress and Presence of Hypertension Among Administrative Officers in Sri Lanka
Gamage, Anuji Upekshika; De Alwis Seneviratne, Rohini
2016-01-01
A cross-sectional survey was carried out among 275 and 760 randomly selected senior officers (SOs) and managerial assistants (MAs) aged between 30 and 60 years. Sum of scores of efforts, rewards, and overcommitment and effort–reward ratio assessed job stress. Blood pressure was measured and classified using JNC-7 guidelines. The response rates of SOs and MAs were 98.9% and 97.2%, respectively. The prevalence of job stress based on high effort–rewards imbalance among SOs and MAs was 74.6% and 80.5%, respectively. The prevalence of overcommitment among SOs and MAs was 35.3% and 29%, respectively. Statistically significant differences (P = .05) were observed between the prevalence of effort–reward imbalance and overcommitment among SOs and MAs. Multivariate analysis indicated effort–reward imbalance (odds ratio [OR] = 2.8; 95% confidence interval [CI] = 1.1–7.4), high efforts (OR = 2.5; 95% CI = 1.2–5.3), and overcommitment (OR = 2.5; 95% CI = 1.1–5.6) were significantly associated with hypertension among SOs. Similarly, effort–reward imbalance and high efforts increased the risk of hypertension by 2-fold (OR = 2.2; 95% CI = 1.1–4.2) and 3-fold (OR = 3.02; 95% CI = 1.9–4.8), respectively, among the MAs. A significant number of administrators are afflicted by job stress, and job stress was significantly associated with hypertension. PMID:26276363
A research agenda for the European Association for Endoscopic Surgeons (EAES).
Francis, Nader; Kazaryan, Airazat M; Pietrabissa, Andrea; Goitein, David; Yiannakopoulou, Eugenia; Agresta, Ferdinando; Khatkov, Igor; Schulze, Svend; Arulampalam, Tan; Tomulescu, Victor; Kim, Young-Woo; Targarona, Eduardo Mª; Zaninotto, Giovanni
2017-05-01
The European Association of Endoscopic Surgeons (EAES) conducted this study aiming to identify the top research questions which are relevant to surgeons in Minimal Access Surgery (MAS). This is in order to promote and link research questions to the current clinical practice in MAS in Europe. Using a systematic methodology, (modified Delphi), the EAES members and leadership teams were surveyed to obtain consensus on the top research priorities in MAS. The responses were categorized and redistributed to the membership to rate the level of importance of each research question. The data were reported as the weighted average score with a scale from 1 (lowest agreement) to 5 (highest agreement). In total, 324 of 2580 (12.5%) of the EAES members and the leaders responded to the survey and contributed to the final consensus. The ranked responses over the 80th percentile identified 39 research priorities with rating ranged from 4.22 to 3.67. The top five highest ranking research priorities in the EAES were centered on improving training in MAS, laparoscopic surgery for benign upper gastrointestinal conditions, integration of novel technology in OR, translational and basic science research in bariatric surgery and investigating the role of MAS in rectal cancer. An EAES research agenda was developed using a systematic methodology and can be used to focus MAS research. This study was commissioned by the European Association for Endoscopic Surgery (EAES).
NASA Astrophysics Data System (ADS)
Robertson, Aiden J.; Pandey, Manoj Kumar; Marsh, Andrew; Nishiyama, Yusuke; Brown, Steven P.
2015-11-01
A selective saturation pulse at fast magic angle spinning (MAS) frequencies (60+ kHz) suppresses t1 noise in the indirect dimension of two-dimensional 1H MAS NMR spectra. The method is applied to a synthetic nucleoside with an intense methyl 1H signal due to triisopropylsilyl (TIPS) protecting groups. Enhanced performance in terms of suppressing the methyl signal while minimising the loss of signal intensity of nearby resonances of interest relies on reducing spin diffusion - this is quantified by comparing two-dimensional 1H NOESY-like spin diffusion spectra recorded at 30-70 kHz MAS. For a saturation pulse centred at the methyl resonance, the effect of changing the nutation frequency at different MAS frequencies as well as the effect of changing the pulse duration is investigated. By applying a pulse of duration 30 ms and nutation frequency 725 Hz at 70 kHz MAS, a good compromise of significant suppression of the methyl resonance combined with the signal intensity of resonances greater than 5 ppm away from the methyl resonance being largely unaffected is achieved. The effectiveness of using a selective saturation pulse is demonstrated for both homonuclear 1H-1H double quantum (DQ)/single quantum (SQ) MAS and 14N-1H heteronuclear multiple quantum coherence (HMQC) two-dimensional solid-state NMR experiments.
Saberi, Shadan; Dehghani, Aghdas; Nematbakhsh, Mehdi
2016-01-01
The angiotensin 1-7 (Ang 1-7), is abundantly produced in kidneys and antagonizes the function of angiotensin II through Mas receptor (MasR) or other unknown mechanisms. In the current study, the role of MasR and steroid hormone estrogen on renal blood flow response to Ang 1-7 administration was investigated in ovariectomized (OV) female rats. OV female Wistar-rats received estradiol (500 μg/kg/week) or vehicle for two weeks. In the day of the experiment, the animals were anesthetized, cannulated, and the responses including mean arterial pressure, renal blood flow (RBF), and renal vascular resistance at the constant level of renal perfusion pressure to graded infusion of Ang 1-7 at 0, 100 and 300 ng/kg/min were determined in OV and OV estradiol-treated (OVE) rats, treated with vehicle or MasR antagonist; A779. RBF response to Ang 1-7 infusion increased dose-dependently in vehicle (Pdose <0.001) and A779-treated (Pdose <0.01) animals. However, when MasR was blocked, the RBF response to Ang 1-7 significantly increased in OV animals compared with OVE rats (P<0.05). When estradiol was limited by ovariectomy, A779 increased RBF response to Ang 1-7 administration, while this response was attenuated in OVE animals.
Huang, Zheng-Hao; Chiu, Yu-Chen; Ho, Li-Lu; Fan, Hsiu-Lung; Lu, Chun-Chi
2018-02-01
Adult-onset Still disease (AOSD) is a rare systemic inflammatory disease of unknown etiology characterized by evanescent salmon-pink rash, spiking fever, arthralgia/ arthritis, and lymphadenopathy. AOSD sometimes was fatal when it is complicated by macrophage activation syndrome (MAS) or hemophagocytic lymphohistiocytosis (HLH). Nonetheless, the literature provides no recommendations for treatment of AOSD patients with severe sepsis. A previously healthy 65-year-old man with history of AOSD was referred to our hospital for persistent right lower quadrant abdominal pain for 2 days. One week later, an abdominal wall abscess and hematoma developed by extravasation from the inferior epigastric vessels, complicated by necrotizing fasciitis of the right thigh and groin region. To our best knowledge, this case was the first reported case of a perforated appendix complicated with necrotizing fasciitis in a patient with AOSD. The patient was diagnosed as acute appendicitis complicated with necrotizing fasciitis and abdominal wall abscess. This case received intravenous tigecycline injection and daily 10 mg prednisolone initially, and shifted to daily intravenous hydrocortisone 200 mg for suspected MAS or HLH. This patient underwent surgical intervention and debridement for necrotizing fasciitis. The patient's symptoms progressed worse rapidly. He died from cytomegalovirus viremia and bacterial necrotizing fasciitis complicated by septic shock. (1) The steroid dose was difficult to titrate when AOSD complicated by sepsis. The differential diagnosis from MAS/HLH with bacterial/viral infection related severe sepsis was difficult but critical for decision making from clinicians and rheumatologists. (2) The conservative treatment with antibiotics for perforated appendix is safe but has a higher failure rate in immunocomprised patients such as systemic lupus erythematosus and AOSD. Early surgical intervention might contribute to better outcome. (3) The abdominal wall abscess can be spread from intra-abdominal lesion through the inferior epigastric vessels which were as weak points of abdominal wall. Imaging examinations contribute to acute diagnosis and help surgeons perform surgical interventions to prevent morbidity and mortality.
Ashbrook, Sharon E; Wimperis, Stephen
2009-11-21
Spin-locking of spin I=3/2 and I=5/2 nuclei in the presence of small resonance offset and second-order quadrupolar interactions has been investigated using both exact and approximate theoretical and experimental nuclear magnetic resonance (NMR) approaches. In the presence of second-order quadrupolar interactions, we show that the initial rapid dephasing that arises from the noncommutation of the state prepared by the first pulse and the spin-locking Hamiltonian gives rise to tensor components of the spin density matrix that are antisymmetric with respect to inversion, in addition to those symmetric with respect to inversion that are found when only a first-order quadrupolar interaction is considered. We also find that spin-locking of multiple-quantum coherence in a static solid is much more sensitive to resonance offset than that of single-quantum coherence and show that good spin-locking of multiple-quantum coherence can still be achieved if the resonance offset matches the second-order shift of the multiple-quantum coherence in the appropriate reference frame. Under magic angle spinning (MAS) conditions, and in the "adiabatic" limit, we demonstrate that rotor-driven interconversion of central-transition single- and three-quantum coherences for a spin I=3/2 nucleus can be best achieved by performing the spin-locking on resonance with the three-quantum coherence in the three-quantum frame. Finally, in the "sudden" MAS limit, we show that spin I=3/2 spin-locking behavior is generally similar to that found in static solids, except when the central-transition nutation rate matches a multiple of the MAS rate and a variety of rotary resonance phenomena are observed depending on the internal spin interactions present. This investigation should aid in the application of spin-locking techniques to multiple-quantum NMR of quadrupolar nuclei and of cross-polarization and homonuclear dipolar recoupling experiments to quadrupolar nuclei such as (7)Li, (11)B, (17)O, (23)Na, and (27)Al.
Haptic Recreation of Elbow Spasticity
Kim, Jonghyun; Damiano, Diane L.
2013-01-01
The aim of this paper is to develop a haptic device capable of presenting standardized recreation of elbow spasticity. Using the haptic device, clinicians will be able to repeatedly practice the assessment of spasticity without requiring patient involvement, and these practice opportunities will help improve accuracy and reliability of the assessment itself. Haptic elbow spasticity simulator (HESS) was designed and prototyped according to mechanical requirements to recreate the feel of elbow spasticity. Based on the data collected from subjects with elbow spasticity, a mathematical model representing elbow spasticity is proposed. As an attempt to differentiate the feel of each score in Modified Ashworth Scale (MAS), parameters of the model were obtained respectively for three different MAS scores 1, 1+, and 2. The implemented haptic recreation was evaluated by experienced clinicians who were asked to give MAS scores by manipulating the haptic device. The clinicians who participated in the study were blinded to each other’s scores and to the given models. They distinguished the three models and the MAS scores given to the recreated models matched 100% with the original MAS scores from the patients. PMID:22275660
Optimized Spectral Editing of 13C MAS NMR Spectra of Rigid Solids Using Cross-Polarization Methods
NASA Astrophysics Data System (ADS)
Sangill, R.; Rastrupandersen, N.; Bildsoe, H.; Jakobsen, H. J.; Nielsen, N. C.
Combinations of 13C magic-angle spinning (MAS) NMR experiments employing cross polarization (CP), cross polarization-depolarization (CPD), and cross polarization-depolarization-repolarization are analyzed quantitatively to derive simple and general procedures for optimized spectral editing of 13C CP/MAS NMR spectra of rigid solids by separation of the 13C resonances into CH n subspectra ( n = 0, 1, 2, and 3). Special attention is devoted to a differentiation by CPD/MAS of CH and CH 2 resonances since these groups behave quite similarly during spin lock under Hartmann-Hahn match and are therefore generally difficult to distinguish unambiguously. A general procedure for the design of subexperiments and linear combinations of their spectra to provide optimized signal-to-noise ratios for the edited subspectra is described. The technique is illustrated by a series of edited 13C CP/MAS spectra for a number of rigid solids ranging from simple organic compounds (sucrose and l-menthol) to complex pharmaceutical products (calcipotriol monohydrate and vitamin D 3) and polymers (polypropylene, polyvinyl alcohol, polyvinyl chloride, and polystyrene).
Thurber, Kent R.; Potapov, Alexey; Yau, Wai-Ming; Tycko, Robert
2012-01-01
We describe an apparatus for solid state nuclear magnetic resonance (NMR) with dynamic nuclear polarization (DNP) and magic-angle spinning (MAS) at 20–25 K and 9.4 Tesla. The MAS NMR probe uses helium to cool the sample space and nitrogen gas for MAS drive and bearings, as described earlier (Thurber et al., J. Magn. Reson. 2008) [1], but also includes a corrugated waveguide for transmission of microwaves from below the probe to the sample. With a 30 mW circularly polarized microwave source at 264 GHz, MAS at 6.8 kHz, and 21 K sample temperature, greater than 25-fold enhancements of cross-polarized 13C NMR signals are observed in spectra of frozen glycerol/water solutions containing the triradical dopant DOTOPA-TEMPO when microwaves are applied. As demonstrations, we present DNP-enhanced one-dimensional and two-dimensional 13C MAS NMR spectra of frozen solutions of uniformly 13C-labeled L-alanine and melittin, a 26-residue helical peptide that we have synthesized with four uniformly 13C-labeled amino acids. PMID:23238592
Vermathen, Martina; Marzorati, Mattia; Vermathen, Peter
2012-01-01
Classical liquid-state high-resolution (HR) NMR spectroscopy has proved a powerful tool in the metabonomic analysis of liquid food samples like fruit juices. In this paper the application of (1)H high-resolution magic angle spinning (HR-MAS) NMR spectroscopy to apple tissue is presented probing its potential for metabonomic studies. The (1)H HR-MAS NMR spectra are discussed in terms of the chemical composition of apple tissue and compared to liquid-state NMR spectra of apple juice. Differences indicate that specific metabolic changes are induced by juice preparation. The feasibility of HR-MAS NMR-based multivariate analysis is demonstrated by a study distinguishing three different apple cultivars by principal component analysis (PCA). Preliminary results are shown from subsequent studies comparing three different cultivation methods by means of PCA and partial least squares discriminant analysis (PLS-DA) of the HR-MAS NMR data. The compounds responsible for discriminating organically grown apples are discussed. Finally, an outlook of our ongoing work is given including a longitudinal study on apples.
Hybrid Modified K-Means with C4.5 for Intrusion Detection Systems in Multiagent Systems
Laftah Al-Yaseen, Wathiq; Ali Othman, Zulaiha; Ahmad Nazri, Mohd Zakree
2015-01-01
Presently, the processing time and performance of intrusion detection systems are of great importance due to the increased speed of traffic data networks and a growing number of attacks on networks and computers. Several approaches have been proposed to address this issue, including hybridizing with several algorithms. However, this paper aims at proposing a hybrid of modified K-means with C4.5 intrusion detection system in a multiagent system (MAS-IDS). The MAS-IDS consists of three agents, namely, coordinator, analysis, and communication agent. The basic concept underpinning the utilized MAS is dividing the large captured network dataset into a number of subsets and distributing these to a number of agents depending on the data network size and core CPU availability. KDD Cup 1999 dataset is used for evaluation. The proposed hybrid modified K-means with C4.5 classification in MAS is developed in JADE platform. The results show that compared to the current methods, the MAS-IDS reduces the IDS processing time by up to 70%, while improving the detection accuracy. PMID:26161437
Hybrid Modified K-Means with C4.5 for Intrusion Detection Systems in Multiagent Systems.
Laftah Al-Yaseen, Wathiq; Ali Othman, Zulaiha; Ahmad Nazri, Mohd Zakree
2015-01-01
Presently, the processing time and performance of intrusion detection systems are of great importance due to the increased speed of traffic data networks and a growing number of attacks on networks and computers. Several approaches have been proposed to address this issue, including hybridizing with several algorithms. However, this paper aims at proposing a hybrid of modified K-means with C4.5 intrusion detection system in a multiagent system (MAS-IDS). The MAS-IDS consists of three agents, namely, coordinator, analysis, and communication agent. The basic concept underpinning the utilized MAS is dividing the large captured network dataset into a number of subsets and distributing these to a number of agents depending on the data network size and core CPU availability. KDD Cup 1999 dataset is used for evaluation. The proposed hybrid modified K-means with C4.5 classification in MAS is developed in JADE platform. The results show that compared to the current methods, the MAS-IDS reduces the IDS processing time by up to 70%, while improving the detection accuracy.
Thurber, Kent R; Potapov, Alexey; Yau, Wai-Ming; Tycko, Robert
2013-01-01
We describe an apparatus for solid state nuclear magnetic resonance (NMR) with dynamic nuclear polarization (DNP) and magic-angle spinning (MAS) at 20-25 K and 9.4 Tesla. The MAS NMR probe uses helium to cool the sample space and nitrogen gas for MAS drive and bearings, as described earlier, but also includes a corrugated waveguide for transmission of microwaves from below the probe to the sample. With a 30 mW circularly polarized microwave source at 264 GHz, MAS at 6.8 kHz, and 21 K sample temperature, greater than 25-fold enhancements of cross-polarized (13)C NMR signals are observed in spectra of frozen glycerol/water solutions containing the triradical dopant DOTOPA-TEMPO when microwaves are applied. As demonstrations, we present DNP-enhanced one-dimensional and two-dimensional (13)C MAS NMR spectra of frozen solutions of uniformly (13)C-labeled l-alanine and melittin, a 26-residue helical peptide that we have synthesized with four uniformly (13)C-labeled amino acids. Published by Elsevier Inc.
Finkler, Fabrine; de Lima, Diane Alves; Cerva, Cristine; Cibulski, Samuel Paulo; Teixeira, Thais Fumaco; Dos Santos, Helton Fernandes; de Almeida, Laura Lopes; Roehe, Paulo Michel; Franco, Ana Cláudia
2016-12-01
Chicken parvovirus (ChPV) has been associated with malabsorption syndrome (MAS) in broilers. However, the participation of this virus in such syndrome is unclear, since it may be detected in diseased and healthy chickens. In the course of these studies, it was argued whether ChPV genome loads might be correlated to the occurrence of MAS. To check such a hypothesis, a SYBR green-based quantitative polymerase chain reaction was developed to detect and quantify ChPV genomes. Cloacal swabs from 68 broilers with MAS and 59 from healthy animals were collected from different poultry farms. Genomes of ChPV were detected in all samples, regardless of their health status. However, viral genome loads in MAS-affected broilers were significantly higher (1 × 10 5 genome copies per 100 ng DNA) than in healthy animals (1.3 × 10 3 GC/100 ng DNA). These findings indicate that there is an association between high ChPV genome loads and the occurrence of MAS in broilers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Choonsik; Kim, Kwang Pyo; Long, Daniel J.
Purpose: To establish an organ dose database for pediatric and adolescent reference individuals undergoing computed tomography (CT) examinations by using Monte Carlo simulation. The data will permit rapid estimates of organ and effective doses for patients of different age, gender, examination type, and CT scanner model. Methods: The Monte Carlo simulation model of a Siemens Sensation 16 CT scanner previously published was employed as a base CT scanner model. A set of absorbed doses for 33 organs/tissues normalized to the product of 100 mAs and CTDI{sub vol} (mGy/100 mAs mGy) was established by coupling the CT scanner model with age-dependentmore » reference pediatric hybrid phantoms. A series of single axial scans from the top of head to the feet of the phantoms was performed at a slice thickness of 10 mm, and at tube potentials of 80, 100, and 120 kVp. Using the established CTDI{sub vol}- and 100 mAs-normalized dose matrix, organ doses for different pediatric phantoms undergoing head, chest, abdomen-pelvis, and chest-abdomen-pelvis (CAP) scans with the Siemens Sensation 16 scanner were estimated and analyzed. The results were then compared with the values obtained from three independent published methods: CT-Expo software, organ dose for abdominal CT scan derived empirically from patient abdominal circumference, and effective dose per dose-length product (DLP). Results: Organ and effective doses were calculated and normalized to 100 mAs and CTDI{sub vol} for different CT examinations. At the same technical setting, dose to the organs, which were entirely included in the CT beam coverage, were higher by from 40 to 80% for newborn phantoms compared to those of 15-year phantoms. An increase of tube potential from 80 to 120 kVp resulted in 2.5-2.9-fold greater brain dose for head scans. The results from this study were compared with three different published studies and/or techniques. First, organ doses were compared to those given by CT-Expo which revealed dose differences up to several-fold when organs were partially included in the scan coverage. Second, selected organ doses from our calculations agreed to within 20% of values derived from empirical formulae based upon measured patient abdominal circumference. Third, the existing DLP-to-effective dose conversion coefficients tended to be smaller than values given in the present study for all examinations except head scans. Conclusions: A comprehensive organ/effective dose database was established to readily calculate doses for given patients undergoing different CT examinations. The comparisons of our results with the existing studies highlight that use of hybrid phantoms with realistic anatomy is important to improve the accuracy of CT organ dosimetry. The comprehensive pediatric dose data developed here are the first organ-specific pediatric CT scan database based on the realistic pediatric hybrid phantoms which are compliant with the reference data from the International Commission on Radiological Protection (ICRP). The organ dose database is being coupled with an adult organ dose database recently published as part of the development of a user-friendly computer program enabling rapid estimates of organ and effective dose doses for patients of any age, gender, examination types, and CT scanner model.« less
Lu, Tu-Lin; Li, Jin-Ci; Yu, Jiang-Yong; Cai, Bao-Chang; Mao, Chun-Qin; Yin, Fang-Zhou
2014-01-01
Traditional Chinese medicine (TCM) reference standards plays an important role in the quality control of Chinese herbal pieces. This paper overviewed the development of TCM reference standards. By analyzing the 2010 edition of Chinese pharmacopoeia, the application of TCM reference standards in the quality control of Chinese herbal pieces was summarized, and the problems exiting in the system were put forward. In the process of improving the quality control level of Chinese herbal pieces, various kinds of advanced methods and technology should be used to research the characteristic reference standards of Chinese herbal pieces, more and more reasonable reference standards should be introduced in the quality control system of Chinese herbal pieces. This article discussed the solutions in the aspect of TCM reference standards, and future development of quality control on Chinese herbal pieces is prospected.
NASA Astrophysics Data System (ADS)
Colomo-Palacios, Ricardo; Paniagua-Martín, Fernando; García-Crespo, Ángel; Ruiz-Mezcua, Belén
Education for students with disabilities now takes place in a wide range of settings, thus, including a wider range of assistive tools. As a result of this, one of the most interesting application domains of technology enhanced learning is related to the adoption of learning technologies and designs for people with disabilities. Following this unstoppable trend, this paper presents MAS, a software platform aimed to help people with severe intellectual disabilities and cerebral paralysis in their learning processes. MAS, as a technology enhanced learning platform, provides several tools that supports learning and monitoring for people with special needs, including adaptative games, data processing and monitoring tools. Installed in a special needs education institution in Madrid, Spain, MAS provides special educators with a tool that improved students education processes.
1H line width dependence on MAS speed in solid state NMR - Comparison of experiment and simulation
NASA Astrophysics Data System (ADS)
Sternberg, Ulrich; Witter, Raiker; Kuprov, Ilya; Lamley, Jonathan M.; Oss, Andres; Lewandowski, Józef R.; Samoson, Ago
2018-06-01
Recent developments in magic angle spinning (MAS) technology permit spinning frequencies of ≥100 kHz. We examine the effect of such fast MAS rates upon nuclear magnetic resonance proton line widths in the multi-spin system of β-Asp-Ala crystal. We perform powder pattern simulations employing Fokker-Plank approach with periodic boundary conditions and 1H-chemical shift tensors calculated using the bond polarization theory. The theoretical predictions mirror well the experimental results. Both approaches demonstrate that homogeneous broadening has a linear-quadratic dependency on the inverse of the MAS spinning frequency and that, at the faster end of the spinning frequencies, the residual spectral line broadening becomes dominated by chemical shift distributions and susceptibility effects even for crystalline systems.
Dental Perspectives in Fibrous Dysplasia and McCune-Albright Syndrome
Akintoye, Sunday O.; Boyce, Alison M.; Collins, Michael T.
2013-01-01
McCune-Albright syndrome (MAS) is a rare multisystem disorder characterized by the triad of polyostotic fibrous dysplasia (PFD), endocrine disorders and café-au-lait skin pigmentation. Ninety percent of MAS patients have FD lesions in the craniofacial area, resulting in significant orofacial deformity, dental disorders, bone pain and compromised oral health. Maxillo-mandibular FD is also associated with dental developmental disorders, malocclusion, and high caries index. There is limited data on the outcomes of dental treatments in maxillo-mandibular FD/MAS patients, because clinicians and researchers have limited access to patients, and there are concerns that dental surgery may activate quiescent jaw FD lesions to grow aggressively. This report highlights current perspectives on dental management issues associated with maxillo-mandibular FD within the context of MAS. PMID:23953425
NASA Astrophysics Data System (ADS)
Bays, Samuel Eugene
2008-10-01
In the past several years there has been a renewed interest in sodium fast reactor (SFR) technology for the purpose of destroying transuranic waste (TRU) produced by light water reactors (LWR). The utility of SFRs as waste burners is due to the fact that higher neutron energies allow all of the actinides, including the minor actinides (MA), to contribute to fission. It is well understood that many of the design issues of LWR spent nuclear fuel (SNF) disposal in a geologic repository are linked to MAs. Because the probability of fission for essentially all the "non-fissile" MAs is nearly zero at low neutron energies, these isotopes act as a neutron capture sink in most thermal reactor systems. Furthermore, because most of the isotopes produced by these capture reactions are also non-fissile, they too are neutron sinks in most thermal reactor systems. Conversely, with high neutron energies, the MAs can produce neutrons by fast fission. Additionally, capture reactions transmute the MAs into mostly plutonium isotopes, which can fission more readily at any energy. The transmutation of non-fissile into fissile atoms is the premise of the plutonium breeder reactor. In a breeder reactor, not only does the non-fissile "fertile" U-238 atom contribute fast fission neutrons, but also transmutes into fissile Pu-239. The fissile value of the plutonium produced by MA transmutation can only be realized in fast neutron spectra. This is due to the fact that the predominate isotope produced by MA transmutation, Pu-238, is itself not fissile. However, the Pu-238 fission cross section is significantly larger than the original transmutation parent, predominately: Np-237 and Am-241, in the fast energy range. Also, Pu-238's fission cross section and fission-to-capture ratio is almost as high as that of fissile Pu-239 in the fast neutron spectrum. It is also important to note that a neutron absorption in Pu-238, that does not cause fission, will instead produce fissile Pu-239. Given this fast fissile quality and also the fact that Pu-238 is transmuted from Np-237 and Am-241, these MAs are regarded as fertile material in the SFR design proposed by this dissertation. This dissertation demonstrates a SFR design which is dedicated to plutonium breeding by targeting Am-241 transmutation. This SFR design uses a moderated axial transmutation target that functions primarily as a pseudo-blanket fuel, which is reprocessed with the active driver fuel in an integrated recycling strategy. This work demonstrates the cost and feasibility advantages of plutonium breeding via MA transmutation by adopting reactor, reprocessing and fuel technologies previously demonstrated for traditional breeder reactors. The fuel cycle proposed seeks to find a harmony between the waste management advantages of transuranic burning SFRs and the resource sustainability of traditional plutonium breeder SFRs. As a result, the enhanced plutonium conversion from MAs decreases the burner SFR's fuel costs, by extracting more fissile value from the initial TRU purchased through SNF reprocessing.
Ho, Jean K; Nation, Daniel A
2018-05-04
To explore effects of the brain renin-angiotensin system (RAS) on cognition. Systematic review of experimental (non-human) studies assessing cognitive effects of RAS peptides angiotensin-(3-8) [Ang IV] and angiotensin-(1-7) [Ang-(1-7)] and their receptors, the Ang IV receptor (AT4R) and the Mas receptor. Of 450 articles identified, 32 met inclusion criteria. Seven of 11 studies of normal animals found Ang IV had beneficial effects on tests of passive or conditioned avoidance and object recognition. In models of cognitive deficit, eight of nine studies found Ang IV and its analogs (Nle 1 -Ang IV, dihexa, LVV-hemorphin-7) improved performance on spatial working memory and passive avoidance tasks. Two of three studies examining Ang-(1-7) found it benefited memory. Mas receptor removal was associated with reduced fear memory in one study. Studies of cognitive impairment show salutary effects of acute administration of Ang IV and its analogs, as well as AT4R activation. Brain RAS peptides appear most effective administered intracerebroventricularly, close to the time of learning acquisition or retention testing. Ang-(1-7) shows anti-dementia qualities. Copyright © 2018. Published by Elsevier Ltd.
Reduction in radiation doses from paediatric CT scans in Great Britain.
Lee, Choonsik; Pearce, Mark S; Salotti, Jane A; Harbron, Richard W; Little, Mark P; McHugh, Kieran; Chapple, Claire-Louise; Berrington de Gonzalez, Amy
2016-01-01
Although CT scans provide great medical benefits, concerns have been raised about the magnitude of possible associated cancer risk, particularly in children who are more sensitive to radiation than adults. Unnecessary high doses during CT examinations can also be delivered to children, if the scan parameters are not adjusted for patient age and size. We conducted the first survey to directly assess the trends in CT scan parameters and doses for paediatric CT scans performed in Great Britain between 1978 and 2008. We retrieved 1073 CT film sets from 36 hospitals. The patients were 0-19 years old, and CT scans were conducted between 1978 and 2008. We extracted scan parameters from each film including tube current-time product [milliampere seconds (mAs)], tube potential [peak kilovoltage (kVp)] and manufacturer and model of the CT scanner. We estimated the mean mAs for head and trunk (chest and abdomen/pelvis) scans, according to patient age (0-4, 5-9, 10-14 and 15-19 years) and scan year (<1990, 1990-1994, 1995-1999 and ≥2000), and then derived the volumetric CT dose index and estimated organ doses. For head CT scans, mean mAs decreased by about 47% on average from before 1990 to after 2000, with the decrease starting around 1990. The mean mAs for head CTs did not vary with age before 1990, whereas slightly lower mAs values were used for younger patients after 1990. Similar declines in mAs were observed for trunk CTs: a 46% decline on an average from before 1990 to after 2000. Although mean mAs for trunk CTs did not vary with age before 1990, the value varied markedly by age, from 63 mAs for age 0-4 years compared with 315 mAs for those aged >15 years after 2000. No material changes in kVp were found. Estimated brain-absorbed dose from head CT scans decreased from 62 mGy before 1990 to approximately 30 mGy after 2000. For chest CT scans, the lung dose to children aged 0-4 years decreased from 28 mGy before 1990 to 4 mGy after 2000. We found that mAs for head and trunk CTs was approximately halved starting around 1990, and age-specific mAs was generally used for paediatric scans after this date. These changes will have substantially reduced the radiation exposure to children from CT scans in Great Britain. The study shows that mAs and major organ doses for paediatric CT scans in Great Britain began to decrease around 1990.
Reduction in radiation doses from paediatric CT scans in Great Britain
Pearce, Mark S; Salotti, Jane A; Harbron, Richard W; Little, Mark P; McHugh, Kieran; Chapple, Claire-Louise; Berrington de Gonzalez, Amy
2016-01-01
Objective: Although CT scans provide great medical benefits, concerns have been raised about the magnitude of possible associated cancer risk, particularly in children who are more sensitive to radiation than adults. Unnecessary high doses during CT examinations can also be delivered to children, if the scan parameters are not adjusted for patient age and size. We conducted the first survey to directly assess the trends in CT scan parameters and doses for paediatric CT scans performed in Great Britain between 1978 and 2008. Methods: We retrieved 1073 CT film sets from 36 hospitals. The patients were 0–19 years old, and CT scans were conducted between 1978 and 2008. We extracted scan parameters from each film including tube current–time product [milliampere seconds (mAs)], tube potential [peak kilovoltage (kVp)] and manufacturer and model of the CT scanner. We estimated the mean mAs for head and trunk (chest and abdomen/pelvis) scans, according to patient age (0–4, 5–9, 10–14 and 15–19 years) and scan year (<1990, 1990–1994, 1995–1999 and ≥2000), and then derived the volumetric CT dose index and estimated organ doses. Results: For head CT scans, mean mAs decreased by about 47% on average from before 1990 to after 2000, with the decrease starting around 1990. The mean mAs for head CTs did not vary with age before 1990, whereas slightly lower mAs values were used for younger patients after 1990. Similar declines in mAs were observed for trunk CTs: a 46% decline on an average from before 1990 to after 2000. Although mean mAs for trunk CTs did not vary with age before 1990, the value varied markedly by age, from 63 mAs for age 0–4 years compared with 315 mAs for those aged >15 years after 2000. No material changes in kVp were found. Estimated brain-absorbed dose from head CT scans decreased from 62 mGy before 1990 to approximately 30 mGy after 2000. For chest CT scans, the lung dose to children aged 0–4 years decreased from 28 mGy before 1990 to 4 mGy after 2000. Conclusion: We found that mAs for head and trunk CTs was approximately halved starting around 1990, and age-specific mAs was generally used for paediatric scans after this date. These changes will have substantially reduced the radiation exposure to children from CT scans in Great Britain. Advances in knowledge: The study shows that mAs and major organ doses for paediatric CT scans in Great Britain began to decrease around 1990. PMID:26864156
Childress, Ann C.; Greenbaum, Michael; Yu, Ming; Yan, Brian; Jaffee, Margo; Robertson, Brigitte
2018-01-01
Abstract Objective: The aim of this study was to evaluate the efficacy, safety, and tolerability of SHP465 mixed amphetamine salts (MAS) in children and adolescents with attention-deficit/hyperactivity disorder (ADHD). Methods: This randomized, double-blind dose-optimization study enrolled children and adolescents (6–17 years) meeting Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision ADHD criteria and having baseline ADHD Rating Scale IV (ADHD-RS-IV) total scores ≥28. Participants were randomized 1:1 to placebo or dose-optimized SHP465 MAS (12.5–25 mg) for 4 weeks. Total score change (baseline to week 4) on the ADHD-RS-IV (primary endpoint) and the Clinical Global Impressions-Improvement (CGI-I) scale score at week 4 (key secondary endpoint) were assessed using linear mixed-effects models for repeated measures. Safety and tolerability assessments (secondary endpoints) included treatment-emergent adverse events (TEAEs) and vital sign changes. Results: Of 264 randomized participants (placebo, n = 132; SHP465 MAS, n = 132), 234 (placebo, n = 118; SHP465 MAS, n = 116) completed the study. The least squares mean (95% confidence interval) treatment difference significantly favored SHP465 MAS over placebo for ADHD-RS-IV total score change from baseline to week 4 (−9.9 [−13.0, −6.8]; p < 0.001; effect size = 0.80) and CGI-I score at week 4 (−0.8 [−1.1, −0.5]; p < 0.001; effect size = 0.65). TEAE frequency was 46.6% (61/131) with placebo and 67.4% (89/132) with SHP465 MAS; no serious TEAEs were reported. TEAEs reported at a frequency of ≥5% and ≥2 times the placebo rate were decreased appetite, insomnia, irritability, nausea, and decreased weight. Mean ± standard deviation increases (baseline to final on-treatment assessment) were higher with SHP465 MAS than placebo for pulse (5.7 ± 11.78 vs. 0.7 ± 10.79), systolic blood pressure (3.8 ± 9.15 vs. 2.1 ± 8.72), and diastolic blood pressure (4.0 ± 8.23 vs. 0.5 ± 7.45). Conclusions: SHP465 MAS demonstrated superiority over placebo in improving ADHD symptoms and global functioning in children and adolescents with ADHD. The safety and tolerability profile of SHP465 MAS was consistent with that of SHP465 MAS in adults and other long-acting psychostimulants in children and adolescents. PMID:28816509
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhuang, Xiahai, E-mail: zhuangxiahai@sjtu.edu.cn; Qian, Xiaohua; Bai, Wenjia
Purpose: Cardiac computed tomography (CT) is widely used in clinical diagnosis of cardiovascular diseases. Whole heart segmentation (WHS) plays a vital role in developing new clinical applications of cardiac CT. However, the shape and appearance of the heart can vary greatly across different scans, making the automatic segmentation particularly challenging. The objective of this work is to develop and evaluate a multiatlas segmentation (MAS) scheme using a new atlas ranking and selection algorithm for automatic WHS of CT data. Research on different MAS strategies and their influence on WHS performance are limited. This work provides a detailed comparison study evaluatingmore » the impacts of label fusion, atlas ranking, and sizes of the atlas database on the segmentation performance. Methods: Atlases in a database were registered to the target image using a hierarchical registration scheme specifically designed for cardiac images. A subset of the atlases were selected for label fusion, according to the authors’ proposed atlas ranking criterion which evaluated the performance of each atlas by computing the conditional entropy of the target image given the propagated atlas labeling. Joint label fusion was used to combine multiple label estimates to obtain the final segmentation. The authors used 30 clinical cardiac CT angiography (CTA) images to evaluate the proposed MAS scheme and to investigate different segmentation strategies. Results: The mean WHS Dice score of the proposed MAS method was 0.918 ± 0.021, and the mean runtime for one case was 13.2 min on a workstation. This MAS scheme using joint label fusion generated significantly better Dice scores than the other label fusion strategies, including majority voting (0.901 ± 0.276, p < 0.01), locally weighted voting (0.905 ± 0.0247, p < 0.01), and probabilistic patch-based fusion (0.909 ± 0.0249, p < 0.01). In the atlas ranking study, the proposed criterion based on conditional entropy yielded a performance curve with higher WHS Dice scores compared to the conventional schemes (p < 0.03). In the atlas database study, the authors showed that the MAS using larger atlas databases generated better performance curves than the MAS using smaller ones, indicating larger atlas databases could produce more accurate segmentation. Conclusions: The authors have developed a new MAS framework for automatic WHS of CTA and investigated alternative implementations of MAS. With the proposed atlas ranking algorithm and joint label fusion, the MAS scheme is able to generate accurate segmentation within practically acceptable computation time. This method can be useful for the development of new clinical applications of cardiac CT.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cozar, O.; Filip, C.; Tripon, C.
The plasticizing - antiplasticizing effect of water and glycerol contents on native corn starch samples is investigated by FT-Raman and {sup 13}C CP/MAS NMR spectroscopy. The presence of both amorphous and crystalline structural phases was evidenced in pure native corn starch and also in the samples containing plasticizers. Among the crystalline starch structures, the A- and V- types were suggested by CP/MAS NMR spectra.
U.S. Geological Survey mineral databases; MRDS and MAS/MILS
McFaul, E.J.; Mason, G.T.; Ferguson, W.B.; Lipin, B.R.
2000-01-01
These two CD-ROM's contain the latest version of the Mineral Resources Data System (MRDS) database and the Minerals Availability System/Minerals Industry Location System (MAS/MILS) database for coverage of North America and the world outside North America. The records in the MRDS database each contain almost 200 data fields describing metallic and nonmetallic mineral resources, deposits, and commodities. The records in the MAS/MILS database each contain almost 100 data fields describing mines and mineral processing plans.
MAS2-8 radar and digital control unit
NASA Technical Reports Server (NTRS)
Oberg, J. M.; Ulaby, F. T.
1974-01-01
The design of the MAS 2-8 (2 to 8 GHz microwave-active spectrometer), a ground-based sensor system, is presented. A major modification in 1974 to the MAS 2-8, that of a control subsystem to automate the data-taking operation, is the prime focus. The digital control unit automatically changes all system parameters except FM rate and records the return signal on paper tape. The overall system operation and a detailed discussion of the design and operation of the digital control unit are presented.
Peters, Sinead E; Brennan, Patrick C
2002-09-01
Manufacturers offer exposure indices as a safeguard against overexposure in computed radiography, but the basis for recommended values is unclear. This study establishes an optimum exposure index to be used as a guideline for a specific CR system to minimise radiation exposures for computed mobile chest radiography, and compares this with manufacturer guidelines and current practice. An anthropomorphic phantom was employed to establish the minimum milliamperes consistent with acceptable image quality for mobile chest radiography images. This was found to be 2 mAs. Consecutively, 10 patients were exposed with this optimised milliampere value and 10 patients were exposed with the 3.2 mAs routinely used in the department of the study. Image quality was objectively assessed using anatomical criteria. Retrospective analyses of 717 exposure indices recorded over 2 months from mobile chest examinations were performed. The optimised milliampere value provided a significant reduction of the average exposure index from 1840 to 1570 ( p<0.0001). This new "optimum" exposure index is substantially lower than manufacturer guidelines of 2000 and significantly lower than exposure indices from the retrospective study (1890). Retrospective data showed a significant increase in exposure indices if the examination was performed out of hours. The data provided by this study emphasise the need for clinicians and personnel to consider establishing their own optimum exposure indices for digital investigations rather than simply accepting manufacturers' guidelines. Such an approach, along with regular monitoring of indices, may result in a substantial reduction in patient exposure.
Mono or polycrystalline alumina-modified hybrid ceramics.
Kaizer, Marina R; Gonçalves, Ana Paula R; Soares, Priscilla B F; Zhang, Yu; Cesar, Paulo F; Cava, Sergio S; Moraes, Rafael R
2016-03-01
This study evaluated the effect of addition of alumina particles (polycrystalline or monocrystalline), with or without silica coating, on the optical and mechanical properties of a porcelain. Groups tested were: control (C), polycrystalline alumina (PA), polycrystalline alumina-silica (PAS), monocrystalline alumina (MA), monocrystalline alumina-silica (MAS). Polycrystalline alumina powder was synthesized using a polymeric precursor method; a commercially available monocrystalline alumina powder (sapphire) was acquired. Silica coating was obtained by immersing alumina powders in a tetraethylorthosilicate solution, followed by heat-treatment. Electrostatic stable suspension method was used to ensure homogenous dispersion of the alumina particles within the porcelain powder. The ceramic specimens were obtained by heat-pressing. Microstructure, translucency parameter, contrast ratio, opalescence index, porosity, biaxial flexural strength, roughness, and elastic constants were characterized. A better interaction between glass matrix and silica coated crystalline particles is suggested in some analyses, yet further investigation is needed to confirm it. The materials did not present significant differences in biaxial flexural strength, due to the presence of higher porosity in the groups with alumina addition. Elastic modulus was higher for MA and MAS groups. Also, these were the groups with optical qualities and roughness closer to control. The PA and PAS groups were considerably more opaque as well as rougher. Porcelains with addition of monocrystalline particles presented superior esthetic qualities compared to those with polycrystalline particles. In order to eliminate the porosity in the ceramic materials investigated herein, processing parameters need to be optimized as well as different glass frites should be tested. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Copper Filtration and kVp: Effect on Entrance Skin Exposure.
Barba, James; Culp, Melissa
2015-01-01
The selection of technical factors to produce an image is driven primarily by the patient, body part, and factors regarding the status of that patient or part. Analog receptor systems are restricted by the ranges of data they are able to record, as well as the quantity and quality of data required to record an image. Using digital receptors allows for a wider range of exposure factors because of the nature of the receptor systems and the data processing methods employed. Thus, factor selection can be more patient centered when using digital receptors to produce a radiograph. To explore the relationship between milliampere seconds (mAs), kilovoltage peak (kVp), and additional copper filtration with exposure indicators and entrance skin exposure (ESE) using both analog and digital receptors. Researchers conducted 2-tailed t-tests using Stata/IC version 11.2 software (StataCorp LP) to compare ESE from several trials using hip and knee phantoms. The analysis indicated that increasing kVp, adding 0.1 mm copper filtration, and correspondingly reducing mAs reduced ESE on a hip phantom by 64%, from 151 mR to 54.4 mR and reduced ESE on a knee phantom by 51%, from 27.2 mR to 13.4 mR. Radiology departments and radiologic technologists can consider these data when creating dose reduction protocols. The wider latitude range of digital radiography can be used to minimize patient exposure while still producing images of diagnostic quality within the acceptable exposure indicator range stated by the manufacturer.
Ubiquitous Presence and Novel Diversity of Anaerobic Alkane Degraders in Cold Marine Sediments.
Gittel, Antje; Donhauser, Johanna; Røy, Hans; Girguis, Peter R; Jørgensen, Bo B; Kjeldsen, Kasper U
2015-01-01
Alkanes are major constituents of crude oil and are released to the marine environment by natural seepage and from anthropogenic sources. Due to their chemical inertness, their removal from anoxic marine sediments is primarily controlled by the activity of anaerobic alkane-degrading microorganisms. To facilitate comprehensive cultivation-independent surveys of the diversity and distribution of anaerobic alkane degraders, we designed novel PCR primers that cover all known diversity of the 1-methylalkyl succinate synthase gene (masD/assA), which catalyzes the initial activation of alkanes. We studied masD/assA gene diversity in pristine and seepage-impacted Danish coastal sediments, as well as in sediments and alkane-degrading enrichment cultures from the Middle Valley (MV) hydrothermal vent system in the Pacific Northwest. MasD/assA genes were ubiquitously present, and the primers captured the diversity of both known and previously undiscovered masD/assA gene diversity. Seepage sediments were dominated by a single masD/assA gene cluster, which is presumably indicative of a substrate-adapted community, while pristine sediments harbored a diverse range of masD/assA phylotypes including those present in seepage sediments. This rare biosphere of anaerobic alkane degraders will likely increase in abundance in the event of seepage or accidental oil spillage. Nanomolar concentrations of short-chain alkanes (SCA) were detected in pristine and seepage sediments. Interestingly, anaerobic alkane degraders closely related to strain BuS5, the only SCA degrader in pure culture, were found in mesophilic MV enrichments, but not in cold sediments from Danish waters. We propose that the new masD/assA gene lineages in these sediments represent novel phylotypes that are either fueled by naturally occurring low levels of SCA or that metabolize medium- to long-chain alkanes. Our study highlights that masD/assA genes are a relevant diagnostic marker to identify seepage and microseepage, e.g., during prospecting for oil and gas, and may act as an indicator of anthropogenic oil spills in marine sediments.
SU-E-I-71: KVp Dependence of Transmitted Exposure for a Radiography Unit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liang, Y; Lynch, D; So, J
2014-06-01
Purpose: To investigate the kVp dependence of the transmitted exposure for a radiography x-ray unit. Methods: The study used a GE DiscoveryTM XR656 DR unit, a 30 (L) × 30 (W) × 25 cm thick Lucite phantom, two anthropomorphic phantoms (an Alderson RS-310 chest phantom and a 3M skull phantom), an Unfors detector, and a Radcal 10x9-6 ion chamber. We measured the entrance exposure and transmitted exposure of each phantom at 60, 70, 80, 90, 100, 110, 120 kVp for mAs range from 2.5 to 200 mAs, without any additional filter. The FOV is 30×30 cm for the Lucite andmore » chest phantom (AP view), and 20×20 cm for skull phantom (Lateral view). The transmitted exposure was measured at the phantom center of the x-ray exit side. For chest phantom, the transmitted exposures at 3 inch upper right and upper left from the center were also measured. We also checked the reproducibility and accuracy of the DR unit. Results: For each phantom, at every kVp and mAs setting, the transmitted exposure per mAs was calculated and normalized by the relative entrance exposure; the averaged transmitted exposure per mAs at each specific kVp was then determined. For chest phantom, the mean transmitted exposure per mAs was the average of three exit locations. The averaged transmitted exposure per mAs was fit as a power function of kVp. The result showed the transmitted exposure per mAs was approximately proportional to third power of the kVp for two anthropomorphic phantoms and forth power of the kVp for the Lucite phantom. Conclusion: The traditional assumption of fifth power kVp dependence to the transmitted exposure is inaccurate. At the normal radiography kVp range, the transmitted exposure is approximately proportional to third power of the kVp for a typical patient and up to forth power of the kVp for a large patient.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, C; Yu, L; Vrieze, T
Purpose: Added filtration such as tin filter has the potential to improve dose efficiency of x-ray beam in lung-cancer screening CT. However, dose efficiency with added beam filtration is highly dependent on patient attenuation level. In this phantom study, we evaluated the image quality at different tube voltages with and without added tin filter when attenuation level varies. Methods: A 30 x 20 cm anthropomorphic thorax phantom with three added extension rings were used to simulate small (S), medium (M), large (L), and extra-large (XL) adult patients. These phantoms were scanned on a 192-slice CT scanner (Force, Siemens) at 100more » and 120kV without tin filtration, and 100 and 150 kV with tin filtration (100Sn and 150Sn), at multiple dose levels at each kV. Images were reconstructed using iterative reconstruction (ADMIRE, Siemens). Radiation dose was measured with a 0.6 cc ion chamber in the middle and peripheral areas of the phantom. Image quality was assessed using mean image noise at uniform areas in the central region and lung. Radiation dose that is required for each kV to match the noise in a routine lung-cancer CT screening technique (120kV, 25 quality reference mAs) was calculated. Results: At each of the four phantom sizes, 100Sn had the lowest noise in both soft tissue and lung. Compared with 120 kV, 100Sn saved 39%–60% dose for the same noise, depending on phantom size. For the XL phantom (50 by 40 cm), 150Sn provided images with the least beam-hardening artifact in peripheral region. Conclusion: For thoracic CT, added tin filtration can provide considerable dose reduction compared with 120 kV. 100Sn provides better dose efficiencies for all phantom sizes, while 150Sn provides better image quality in peripheral region for extra-large patients. Drs.Joel G. Fletcher and Cynthia H. McCollough receive research support from Siemens Healthcare.« less
Arsenic Demethylation by a C·As Lyase in Cyanobacterium Nostoc sp. PCC 7120.
Yan, Yu; Ye, Jun; Xue, Xi-Mei; Zhu, Yong-Guan
2015-12-15
Arsenic, a ubiquitous toxic substance, exists mainly as inorganic forms in the environment. It is perceived that organoarsenicals can be demethylated and degraded into inorganic arsenic by microorganisms. Few studies have focused on the mechanism of arsenic demethylation in bacteria. Here, we investigated arsenic demethylation in a typical freshwater cyanobacterium Nostoc sp. PCC 7120. This bacterium was able to demethylate monomethylarsenite [MAs(III)] rapidly to arsenite [As(III)] and also had the ability to demethylate monomethylarsenate [MAs(V)] to As(III). The NsarsI encoding a C·As lyase responsible for MAs(III) demethylation was cloned from Nostoc sp. PCC 7120 and heterologously expressed in an As-hypersensitive strain Escherichia coli AW3110 (ΔarsRBC). Expression of NsarsI was shown to confer MAs(III) resistance through arsenic demethylation. The purified NsArsI was further identified and functionally characterized in vitro. NsArsI existed mainly as the trimeric state, and the kinetic data were well-fit to the Hill equation with K0.5 = 7.55 ± 0.33 μM for MAs(III), Vmax = 0.79 ± 0.02 μM min(-1), and h = 2.7. Both of the NsArsI truncated derivatives lacking the C-terminal 10 residues (ArsI10) or 23 residues (ArsI23) had a reduced ability of MAs(III) demethylation. These results provide new insights for understanding the important role of cyanobacteria in arsenic biogeochemical cycling in the environment.
Mistri, S K; Sultana, M; Kamal, S M M; Alam, M M; Irin, F; Nessa, J; Ahsan, C R; Yasmin, M
2016-05-01
For an effective control of tuberculosis, rapid detection of multidrug resistant tuberculosis (MDR-TB) is necessary. Therefore, we developed a modified nested multiplex allele-specific polymerase chain reaction (MAS-PCR) method that enables rapid MDR-TB detection directly from sputum samples. The efficacy of this method was evaluated using 79 sputum samples collected from suspected tuberculosis patients. The performance of nested MAS-PCR method was compared with other MDR-TB detection methods like drug susceptibility testing (DST) and DNA sequencing. As rifampicin (RIF) resistance conforms to MDR-TB in greater than 90% cases, only the presence of RIF-associated mutations in rpoB gene was determined by DNA sequencing and nested MAS-PCR to detect MDR-TB. The concordance between nested MAS-PCR and DNA sequencing results was found to be 96·3%. When compared with DST, the sensitivity and specificity of nested MAS-PCR for RIF-resistance detection were determined to be 92·9 and 100% respectively. For developing- and high-TB burden countries, molecular-based tests have been recommended by the World Health Organization for rapid detection of MDR-TB. The results of this study indicate that, nested MAS-PCR assay might be a practical and relatively cost effective molecular method for rapid detection of MDR-TB from suspected sputum samples in developing countries with resource poor settings. © 2016 The Society for Applied Microbiology.
Robertson, Aiden J; Pandey, Manoj Kumar; Marsh, Andrew; Nishiyama, Yusuke; Brown, Steven P
2015-11-01
A selective saturation pulse at fast magic angle spinning (MAS) frequencies (60+kHz) suppresses t1 noise in the indirect dimension of two-dimensional (1)H MAS NMR spectra. The method is applied to a synthetic nucleoside with an intense methyl (1)H signal due to triisopropylsilyl (TIPS) protecting groups. Enhanced performance in terms of suppressing the methyl signal while minimising the loss of signal intensity of nearby resonances of interest relies on reducing spin diffusion--this is quantified by comparing two-dimensional (1)H NOESY-like spin diffusion spectra recorded at 30-70 kHz MAS. For a saturation pulse centred at the methyl resonance, the effect of changing the nutation frequency at different MAS frequencies as well as the effect of changing the pulse duration is investigated. By applying a pulse of duration 30 ms and nutation frequency 725 Hz at 70 kHz MAS, a good compromise of significant suppression of the methyl resonance combined with the signal intensity of resonances greater than 5 ppm away from the methyl resonance being largely unaffected is achieved. The effectiveness of using a selective saturation pulse is demonstrated for both homonuclear (1)H-(1)H double quantum (DQ)/single quantum (SQ) MAS and (14)N-(1)H heteronuclear multiple quantum coherence (HMQC) two-dimensional solid-state NMR experiments. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Comparison of pulsar positions from timing and very long baseline astrometry
NASA Astrophysics Data System (ADS)
Wang, J. B.; Coles, W. A.; Hobbs, G.; Shannon, R. M.; Manchester, R. N.; Kerr, M.; Yuan, J. P.; Wang, N.; Bailes, M.; Bhat, N. D. R.; Dai, S.; Dempsey, J.; Keith, M. J.; Lasky, P. D.; Levin, Y.; Osłowski, S.; Ravi, V.; Reardon, D. J.; Rosado, P. A.; Russell, C. J.; Spiewak, R.; van Straten, W.; Toomey, L.; Wen, L.; You, X.-P.; Zhu, X.-J.
2017-07-01
Pulsar positions can be measured with high precision using both pulsar timing methods and very long baseline interferometry (VLBI). Pulsar timing positions are referenced to a solar-system ephemeris, whereas VLBI positions are referenced to distant quasars. Here, we compare pulsar positions from published VLBI measurements with those obtained from pulsar timing data from the Nanshan and Parkes radio telescopes in order to relate the two reference frames. We find that the timing positions differ significantly from the VLBI positions (and also differ between different ephemerides). A statistically significant change in the obliquity of the ecliptic of 2.16 ± 0.33 mas is found for the JPL ephemeris DE405, but no significant rotation is found in subsequent JPL ephemerides. The accuracy with which we can relate the two frames is limited by the current uncertainties in the VLBI reference source positions and in matching the pulsars to their reference source. Not only do the timing positions depend on the ephemeris used in computing them, but also different segments of the timing data lead to varying position estimates. These variations are mostly common to all ephemerides, but slight changes are seen at the 10 μas level between ephemerides.
Gibb, Stuart W.; Wood, John W.; Fauzi, R.; Mantoura, C.
1995-01-01
The automation and improved design and performance of Flow Injection Gas Diffusion-Ion Chromatography (FIGD-IC), a novel technique for the simultaneous analysis of trace ammonia (NH3) and methylamines (MAs) in aqueous media, is presented. Automated Flow Injection Gas Diffusion (FIGD) promotes the selective transmembrane diffusion of MAs and NH3 from aqueous sample under strongly alkaline (pH > 12, NaOH), chelated (EDTA) conditions into a recycled acidic acceptor stream. The acceptor is then injected onto an ion chromatograph where NH3 and the MAs are fully resolved as their cations and detected conductimetrically. A versatile PC interfaced control unit and data capture unit (DCU) are employed in series to direct the selonoid valve switching sequence, IC operation and collection of data. Automation, together with other modifications improved both linearily (R2 > 0.99 MAs 0-100 nM, NH3 0-1000 nM) and precision (<8%) of FIGD-IC at nanomolar concentrations, compared with the manual procedure. The system was successfully applied to the determination of MAs and NH3 in seawater and in trapped particulate and gaseous atmospheric samples during an oceanographic research cruise. PMID:18925047
Magnetic resonance imaging of DNP enhancements in a rotor spinning at the magic angle
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perras, Frederic A.; Kobayashi, Takeshi; Pruski, Marek
Simulations performed on model, static, samples have shown that the microwave power is non-uniformly distributed in the magic angle spinning (MAS) rotor when using conventional dynamic nuclear polarization (DNP) instrumentation. Here, we applied the stray-field magic angle spinning imaging (STRAFI–MAS) experiment to generate a spatial map of the DNP enhancements in a full rotor, which is spun at a low rate in a commercial DNP–MAS NMR system. Notably, we observed that the enhancement factors produced in the center of the rotor can be twice as large as those produced at the top of the rotor. Surprisingly, we observed that themore » largest enhancement factors are observed along the axis of the rotor as opposed to against its walls, which are most directly irradiated by the microwave beam. We lastly observed that the distribution of enhancement factors can be moderately improved by degassing the sample and increasing the microwave power. The inclusion of dielectric particles greatly amplifies the enhancement factors throughout the rotor. Furthermore, the STRAFI–MAS approach can provide useful guidance for optimizing the access of microwave power to the sample, and thereby lead to further increases in sensitivity of DNP–MAS NMR.« less
An HR-MAS MR Metabolomics Study on Breast Tissues Obtained with Core Needle Biopsy
Cho, Nariya; Chang, Jung Min; Koo, Hye Ryoung; Yi, Ann; Kim, Hyeonjin; Park, Sunghyouk; Moon, Woo Kyung
2011-01-01
Background Much research has been devoted to the development of new breast cancer diagnostic measures, including those involving high-resolution magic angle spinning (HR-MAS) magnetic resonance (MR) spectroscopic techniques. Previous HR-MAS MR results have been obtained from post-surgery samples, which limits their direct clinical applicability. Methodology/Principal Findings In the present study, we performed HR-MAS MR spectroscopic studies on 31 breast tissue samples (13 cancer and 18 non-cancer) obtained by percutaneous core needle biopsy. We showed that cancer and non-cancer samples can be discriminated very well with Orthogonal Projections to Latent Structure-Discriminant Analysis (OPLS-DA) multivariate model on the MR spectra. A subsequent blind test showed 69% sensitivity and 94% specificity in the prediction of the cancer status. A spectral analysis showed that in cancer cells, taurine- and choline-containing compounds are elevated. Our approach, additionally, could predict the progesterone receptor statuses of the cancer patients. Conclusions/Significance HR-MAS MR metabolomics on intact breast tissues obtained by core needle biopsy may have a potential to be used as a complement to the current diagnostic and prognostic measures for breast cancers. PMID:22028780
A Case of Atypical McCune-Albright Syndrome with Vaginal Bleeding
Rostampour, Noushin; Hashemipour, Mahin; Kelishadi, Roya; Hovsepian, Silva; Hekmatnia, Ali
2011-01-01
Background McCune-Albright syndrome (MAS) is a rare non-inherited disorder characterized by the clinical triad of precocious puberty, cafe-au-lait skin lesions, and fibrous dysplasia of bone. Case Presentation We report a girl with MAS, presenting initially with vaginal bleeding at the age of 17 months. Ultrasonography revealed unilateral ovarian cysts and ureteral and ovarian enlargement. Considering the clinical and paraclinical findings, the patient diagnosed as a case of gonadotropin-independent precocious puberty was treated with medroxy-progestrone acetate (MPA) for three months. During the follow up, recurrent episodes of bleeding, ovarian activation and cyst formation, as well as breast size development were reported. At the age of 5.5 years, fibrous dysplasia was detected, which in coexistence with precocious puberty confirmed the diagnosis of MAS. The patient had no cafe-au-lait skin macles during follow up. Conclusion Considering that clinical manifestations of MAS appear later in the course of recurrent periods of ovarian activation and cyst formation, a careful clinical observation and follow up of patients is necessary and the diagnosis of MAS must be kept in mind in cases with gonadotropin-independent precocious puberty. PMID:23056821
Magnetic resonance imaging of DNP enhancements in a rotor spinning at the magic angle
Perras, Frederic A.; Kobayashi, Takeshi; Pruski, Marek
2016-02-23
Simulations performed on model, static, samples have shown that the microwave power is non-uniformly distributed in the magic angle spinning (MAS) rotor when using conventional dynamic nuclear polarization (DNP) instrumentation. Here, we applied the stray-field magic angle spinning imaging (STRAFI–MAS) experiment to generate a spatial map of the DNP enhancements in a full rotor, which is spun at a low rate in a commercial DNP–MAS NMR system. Notably, we observed that the enhancement factors produced in the center of the rotor can be twice as large as those produced at the top of the rotor. Surprisingly, we observed that themore » largest enhancement factors are observed along the axis of the rotor as opposed to against its walls, which are most directly irradiated by the microwave beam. We lastly observed that the distribution of enhancement factors can be moderately improved by degassing the sample and increasing the microwave power. The inclusion of dielectric particles greatly amplifies the enhancement factors throughout the rotor. Furthermore, the STRAFI–MAS approach can provide useful guidance for optimizing the access of microwave power to the sample, and thereby lead to further increases in sensitivity of DNP–MAS NMR.« less
NASA Astrophysics Data System (ADS)
Suto, Hirofumi; Kanao, Taro; Nagasawa, Tazumi; Mizushima, Koichi; Sato, Rie
2018-05-01
Microwave-assisted magnetization switching (MAS) is attracting attention as a method for reversing nanomagnets with a high magnetic anisotropy by using a small-amplitude magnetic field. We experimentally study MAS of a perpendicularly magnetized nanomagnet by applying a microwave magnetic field with a time-varying frequency. Because the microwave field frequency can follow the nonlinear decrease of the resonance frequency, larger magnetization excitation than that in a constant-frequency microwave field is induced, which enhances the MAS effect. The switching field decreases almost linearly as the start value of the time-varying microwave field frequency increases, and it becomes smaller than the minimum switching field in a constant-frequency microwave field. To obtain this enhancement of the MAS effect, the end value of the time-varying microwave field frequency needs to be almost the same as or lower than the critical frequency for MAS in a constant-frequency microwave field. In addition, the frequency change typically needs to take 1 ns or longer to make the rate of change slow enough for the magnetization to follow the frequency change. This switching behavior is qualitatively explained by the theory based on the macrospin model.
Synthesized view comparison method for no-reference 3D image quality assessment
NASA Astrophysics Data System (ADS)
Luo, Fangzhou; Lin, Chaoyi; Gu, Xiaodong; Ma, Xiaojun
2018-04-01
We develop a no-reference image quality assessment metric to evaluate the quality of synthesized view rendered from the Multi-view Video plus Depth (MVD) format. Our metric is named Synthesized View Comparison (SVC), which is designed for real-time quality monitoring at the receiver side in a 3D-TV system. The metric utilizes the virtual views in the middle which are warped from left and right views by Depth-image-based rendering algorithm (DIBR), and compares the difference between the virtual views rendered from different cameras by Structural SIMilarity (SSIM), a popular 2D full-reference image quality assessment metric. The experimental results indicate that our no-reference quality assessment metric for the synthesized images has competitive prediction performance compared with some classic full-reference image quality assessment metrics.
SU-E-J-178: Development of Image Planning System for Radiation Therapy.
Thapa, B; Molloy, J
2012-06-01
The constraints required for patient imaging dose received during image-guided radiotherapy differ from those applied in the diagnostic realm. Wide latitude in applied dose can be justified if it results in useful improvement in image quality. Currently, image acquisition parameters are chosen via broad categorizations in patient anatomy and imaging goal. Herein, we describe the development and early benchmarking of a patient-specific image planning system that is capable of predetermining the optimal acquisition parameters for a given level of patient dose and imaging goal. An algorithm was written in Matlab that performed a divergent ray-trace through a 3D CT data set and impinges on a flat imaging receptor. Energy-specific attenuation through each voxel of the CT data set is calculated to derive a net transmitted intensity. The detector response as a function of beam quality and exposure was measured and integrated into the algorithm. It is primarily this feature that distinguishes this from a traditional digitally reconstructed radiograph. Verification data was collected using a flat panel imager mounted onto a linear accelerator gantry and a lung phantom with an embedded nodule. Loss of object detectability was evaluated by measuring the visible diameter of the phantom nodule. There is qualitative agreement between simulated and measured images in terms of contrast and object detectability. The simulation algorithm predicts both under-exposure and saturation of the detector over a range of beam qualities (80 keV to 120keV) and exposure levels. Object detectability erodes predictably above 60 mAs for at 80keV and above 15mAs for 120 keV for both simulated and measured images. Quantitative accuracy is currently limited by lack of beam heterogeneity, which will be added in further work. The feasibility and qualitative accuracy of an image planning system has been established. © 2012 American Association of Physicists in Medicine.
Abdurakhmonov, I Y; Kohel, R J; Yu, J Z; Pepper, A E; Abdullaev, A A; Kushanov, F N; Salakhutdinov, I B; Buriev, Z T; Saha, S; Scheffler, B E; Jenkins, J N; Abdukarimov, A
2008-12-01
The narrow genetic base of cultivated cotton germplasm is hindering the cotton productivity worldwide. Although potential genetic diversity exists in Gossypium genus, it is largely 'underutilized' due to photoperiodism and the lack of innovative tools to overcome such challenges. The application of linkage disequilibrium (LD)-based association mapping is an alternative powerful molecular tool to dissect and exploit the natural genetic diversity conserved within cotton germplasm collections, greatly accelerating still 'lagging' cotton marker-assisted selection (MAS) programs. However, the extent of genome-wide linkage disequilibrium (LD) has not been determined in cotton. We report the extent of genome-wide LD and association mapping of fiber quality traits by using a 95 core set of microsatellite markers in a total of 285 exotic Gossypium hirsutum accessions, comprising of 208 landrace stocks and 77 photoperiodic variety accessions. We demonstrated the existence of useful genetic diversity within exotic cotton germplasm. In this germplasm set, 11-12% of SSR loci pairs revealed a significant LD. At the significance threshold (r(2)>/=0.1), a genome-wide average of LD declines within the genetic distance at <10 cM in the landrace stocks germplasm and >30 cM in variety germplasm. Genome wide LD at r(2)>/=0.2 was reduced on average to approximately 1-2 cM in the landrace stock germplasm and 6-8 cM in variety germplasm, providing evidence of the potential for association mapping of agronomically important traits in cotton. We observed significant population structure and relatedness in assayed germplasm. Consequently, the application of the mixed liner model (MLM), considering both kinship (K) and population structure (Q) detected between 6% and 13% of SSR markers associated with the main fiber quality traits in cotton. Our results highlight for the first time the feasibility and potential of association mapping, with consideration of the population structure and stratification existing in cotton germplasm resources. The number of SSR markers associated with fiber quality traits in diverse cotton germplasm, which broadly covered many historical meiotic events, should be useful to effectively exploit potentially new genetic variation by using MAS programs.
Present status of astronomical constants
NASA Astrophysics Data System (ADS)
Fukushima, T.
Given was the additional information to the previous report on the recent progress in the determinations of astronomical constants (Fukushima 2000). First noted was the revision of LG as 6.969290134×10-10 based on the proposal to shift its status from a primary to a defining constant (Petit 2000). Next focused was the significant update of the correction to the current precession constant, Δp, based on the recent LLR-based determination (Chapront et al. 2000) as -0.3164+/-0.0030"/cy. By combining this and the equal weighted average of VLBI determinations (Mathews et al. 2000; Petrov 2000; Shirai and Fukushima 2000; Vondrak and Ron 2000) as -0.2968+/-0.0043"/cy, we derived the best estimate of precession constant as p = 5028.790+/-0.005"/cy. Also redetermined were some other quantities related to the precession formula; namely the offsets of Celestial Ephemeris Pole of the International Celestial Reference System as &Deltaψ0sinɛ0 = (-17.0+/-0.3) mas and Δɛ0 = (-5.1+/-0.3) mas. As a result, the obliquity of the ecliptic at the epoch J2000.0 was estimated as ɛ0 = 23°26'21."4059+/-0."0003. As a summary, presented was the (revised) IAU 2000 File of Current Best Estimates of astronomical constants, which is to replace the former 1994 version (Standish 1995).
ON THE CONNECTION OF THE APPARENT PROPER MOTION AND THE VLBI STRUCTURE OF COMPACT RADIO SOURCES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moor, A.; Frey, S.; Lambert, S. B.
2011-06-15
Many of the compact extragalactic radio sources that are used as fiducial points to define the celestial reference frame are known to have proper motions detectable with long-term geodetic/astrometric very long baseline interferometry (VLBI) measurements. These changes can be as high as several hundred microarcseconds per year for certain objects. When imaged with VLBI at milliarcsecond (mas) angular resolution, these sources (radio-loud active galactic nuclei) typically show structures dominated by a compact, often unresolved 'core' and a one-sided 'jet'. The positional instability of compact radio sources is believed to be connected with changes in their brightness distribution structure. For themore » first time, we test this assumption in a statistical sense on a large sample rather than on only individual objects. We investigate a sample of 62 radio sources for which reliable long-term time series of astrometric positions as well as detailed 8 GHz VLBI brightness distribution models are available. We compare the characteristic direction of their extended jet structure and the direction of their apparent proper motion. We present our data and analysis method, and conclude that there is indeed a correlation between the two characteristic directions. However, there are cases where the {approx}1-10 mas scale VLBI jet directions are significantly misaligned with respect to the apparent proper motion direction.« less
Independent Orbiter Assessment (IOA): Assessment of the mechanical actuation subsystem, volume 2
NASA Technical Reports Server (NTRS)
Bradway, M. W.; Slaughter, W. T.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine draft failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the proposed Post 51-L NASA FMEA/CIL baseline that was available. A resolution of each discrepancy from the comparison was provided through additional analysis as required. These discrepancies were flagged as issues, and recommendations were made based on the FMEA data available at the time. This report documents the results of that comparison for the Orbiter Mechanical Actuation System (MAS) hardware. Specifically, the MAS hardware consists of the following components: Air Data Probe (ADP); Elevon Seal Panel (ESP); External Tank Umbilical (ETU); Ku-Band Deploy (KBD); Payload Bay Doors (PBD); Payload Bay Radiators (PBR); Personnel Hatches (PH); Vent Door Mechanism (VDM); and Startracker Door Mechanism (SDM). Criticality was assigned based upon the severity of the effect for each failure mode. Volume 2 continues the presentation of IOA analysis worksheets and contains the potential critical items list, detailed analysis, and NASA FMEA/CIL to IOA worksheet cross reference and recommendations.
Acrogigantism and facial asymmetry: McCune-Albright syndrome.
Subbiah, Sridhar; Palikhe, Gaurav; Bhadada, Sanjay Kumar; Mukherjee, Kanchan Kumar; Bhansali, Anil
2011-01-01
McCune-Albright syndrome (MAS) is characterized by a triad of poly/monoostotic fibrous dysplasia, café-au-lait macules and hyperfunctioning endocrinopathies. Association of MAS with GH excess is rare, and in most of the instances somatotropinoma has not been documented. Treatment of patients of MAS with acromegaly is difficult because of thickened calvarium and dysplastic skull bone. We report a 17-year-old girl, who presented with cranio-facial fibrous dysplasia, café-au-lait macules and also had acromegaly due to pituitary macroadenoma, and treated with gamma knife radiosurgery.
Recovery of minor actinides from spent fuel using TPEN-immobilized gels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koyama, S.; Suto, M.; Ohbayashi, H.
2013-07-01
A series of separation experiments was performed in order to study the recovery process for minor actinides (MAs), such as americium (Am) and curium (Cm), from the actual spent fuel by using an extraction chromatographic technique. N,N,N',N'-tetrakis-(4-propenyloxy-2-pyridylmethyl) ethylenediamine (TPPEN) is an N,N,N',N'-tetrakis (2-pyridylmethyl) ethylenediamine (TPEN) analogue consisting of an incorporated pyridine ring that acts as not only a ligand but also as a site for polymerization and crosslinking of the gel. The TPPEN and N-isopropylacrylamide (NIPA) were dissolved into dimethylformamide (DMF, Wako Co., Ltd.) and a silica beads polymer, and then TTPEN was immobilized chemically in a polymer gel (somore » called TPEN-gel). Mixed oxide (MOX) fuel, which was highly irradiated up to 119 GWD/MTM in the experimental fast reactor Joyo, was used as a reference spent fuel. First, uranium (U) and plutonium (Pu) were separated from the irradiated fuel using an ion-exchange method, and then, the platinum group elements were removed by CMPO to leave a mixed solution of MAs and lanthanides. The 3 mol% TPPEN-gel was packed with as an extraction column (CV: 1 ml) and then rinsed by 0.1 M NaNO{sub 3}(pH 4.0) for pH adjustment. After washing the column by 0.01 M NaNO{sub 3} (pH 4.0), Eu was detected and the recovery rate reached 93%. The MAs were then recovered by changing the eluent to 0.01 M NaNO{sub 3} (pH 2.0), and the recovery rate of Am was 48 %. The 10 mol% TPPEN-gel was used to improve adsorption coefficient of Am and a condition of eluent temperature was changed in order to confirm the temperature swing effect on TPEN-gel for MA. More than 90% Eu was detected in the eluent after washing with 0.01 M NaNO{sub 3} (pH 3.5) at 5 Celsius degrees. Americium was backwardly detected and eluted continuously during the same condition. After removal of Eu, the eluent temperature was changed to 32 Celsius degrees, then Am was detected (pH 3.0). Finally remained Am could be stripped from TPPEN-gel by changing the pH of the eluent to 2.0. These results These results prove that the proposed recovery process for MAs is a potential candidate for future reprocessing methods based on the extraction chromatographic technique. (authors)« less
O'Neill, Julie; Healy, Vincent; Johns, Edward J
2017-12-01
What is the central question of this study? Dietary sodium manipulation alters the magnitude of angiotensin-(1-7) [Ang-(1-7)]-induced natriuresis. The present study sought to determine whether this was related to relative changes in the activity of intrarenal Mas and/or AT 1 receptors. What is the main finding and its importance? Angiotensin-(1-7)-induced diuresis and natriuresis is mediated by intrarenal Mas receptors. However, intrarenal AT 1 receptor blockade also had an inhibitory effect on Ang-(1-7)-induced natriuresis and diuresis. Thus, Ang-(1-7)-induced increases in sodium and water excretion are dependent upon functional Mas and AT 1 receptors. We investigated whether angiotensin-(1-7) [Ang-(1-7)]-induced renal haemodynamic and excretory actions were solely dependent upon intrarenal Mas receptor activation or required functional angiotensin II type 1 (AT 1 ) receptors. The renin-angiotensin system was enhanced in anaesthetized rats by prior manipulation of dietary sodium intake. Angiotensin-(1-7) and AT 1 and Mas receptor antagonists were infused into the kidney at the corticomedullary border. Mas receptor expression was measured in the kidney. Mean arterial pressure, urine flow and fractional sodium excretion were 93 ± 4 mmHg, 46.1 ± 15.7 μl min -1 kg -1 and 1.4 ± 0.3%, respectively, in the normal-sodium group and 91 ± 2 mmHg, 19.1 ± 3.3 μl min -1 kg -1 and 0.7 ± 0.2%, respectively, in the low-sodium group. Angiotensin-(1-7) infusion had no effect on mean arterial pressure in rats receiving a normal-sodium diet but decreased it by 4 ± 5% in rats receiving a low-sodium diet (P < 0.05). Interstitial Ang-(1-7) infusion increased urine flow twofold and fractional sodium excretion threefold (P < 0.05) in rats receiving a normal-sodium diet and to a greater extent, approximately three- and fourfold, respectively, in rats receiving the low-sodium diet (both P < 0.05). Angiotensin-(1-7)-induced increases in urine flow and fractional sodium excretion were absent in both dietary groups during intrarenal AT 1 or Mas receptor inhibition after either losartan or A-779, respectively. Thus, AT 1 receptor activation, as well as Mas receptor activation, plays an essential role in mediating Ang-(1-7)-induced natriuresis and diuresis. Whether this is because Ang-(1-7) partly antagonizes AT 1 receptors or whether Ang-(1-7)-induced natriuresis is mediated through AT 1 -Mas receptor dimerization remains unclear. © 2017 The Authors. Experimental Physiology © 2017 The Physiological Society.
Nikitovic, M; Brener, S
2013-01-01
As part of ongoing efforts to improve the Ontario health care system, a mega-analysis examining the optimization of chronic disease management in the community was conducted by Evidence Development and Standards, Health Quality Ontario (previously known as the Medical Advisory Secretariat [MAS]). The purpose of this report was to identify health technologies previously evaluated by MAS that may be leveraged in efforts to optimize chronic disease management in the community. The Ontario Health Technology Assessment Series and field evaluations conducted by MAS and its partners between January 1, 2006, and December 31, 2011. Technologies related to at least 1 of 7 disease areas of interest (type 2 diabetes, coronary artery disease, atrial fibrillation, chronic obstructive pulmonary disease, congestive heart failure, stroke, and chronic wounds) or that may greatly impact health services utilization were reviewed. Only technologies with a moderate to high quality of evidence and associated with a clinically or statistically significant improvement in disease management were included. Technologies related to other topics in the mega-analysis on chronic disease management were excluded. Evidence-based analyses were reviewed, and outcomes of interest were extracted. Outcomes of interest included hospital utilization, mortality, health-related quality of life, disease-specific measures, and economic analysis measures. Eleven analyses were included and summarized. Technologies fell into 3 categories: those with evidence for the cure of chronic disease, those with evidence for the prevention of chronic disease, and those with evidence for the management of chronic disease. The impact on patient outcomes and hospitalization rates of new health technologies in chronic disease management is often overlooked. This analysis demonstrates that health technologies can reduce the burden of illness; improve patient outcomes; reduce resource utilization intensity; be cost-effective; and be a viable contributing factor to chronic disease management in the community. People with chronic diseases rely on the health care system to help manage their illness. Hospital use can be costly, so community-based alternatives are often preferred. Research published in the Ontario Health Technology Assessment Series between 2006 and 2011 was reviewed to identify health technologies that have been effective or cost-effective in helping to manage chronic disease in the community. All technologies identified led to better patient outcomes and less use of health services. Most were also cost-effective. Two technologies that can cure chronic disease and 1 that can prevent chronic disease were found. Eight technologies that can help manage chronic disease were also found. Health technologies should be considered an important part of chronic disease management in the community.
Health Technologies for the Improvement of Chronic Disease Management
Nikitovic, M; Brener, S
2013-01-01
Background As part of ongoing efforts to improve the Ontario health care system, a mega-analysis examining the optimization of chronic disease management in the community was conducted by Evidence Development and Standards, Health Quality Ontario (previously known as the Medical Advisory Secretariat [MAS]). Objective The purpose of this report was to identify health technologies previously evaluated by MAS that may be leveraged in efforts to optimize chronic disease management in the community. Data Sources The Ontario Health Technology Assessment Series and field evaluations conducted by MAS and its partners between January 1, 2006, and December 31, 2011. Review Methods Technologies related to at least 1 of 7 disease areas of interest (type 2 diabetes, coronary artery disease, atrial fibrillation, chronic obstructive pulmonary disease, congestive heart failure, stroke, and chronic wounds) or that may greatly impact health services utilization were reviewed. Only technologies with a moderate to high quality of evidence and associated with a clinically or statistically significant improvement in disease management were included. Technologies related to other topics in the mega-analysis on chronic disease management were excluded. Evidence-based analyses were reviewed, and outcomes of interest were extracted. Outcomes of interest included hospital utilization, mortality, health-related quality of life, disease-specific measures, and economic analysis measures. Results Eleven analyses were included and summarized. Technologies fell into 3 categories: those with evidence for the cure of chronic disease, those with evidence for the prevention of chronic disease, and those with evidence for the management of chronic disease. Conclusions The impact on patient outcomes and hospitalization rates of new health technologies in chronic disease management is often overlooked. This analysis demonstrates that health technologies can reduce the burden of illness; improve patient outcomes; reduce resource utilization intensity; be cost-effective; and be a viable contributing factor to chronic disease management in the community. Plain Language Summary People with chronic diseases rely on the health care system to help manage their illness. Hospital use can be costly, so community-based alternatives are often preferred. Research published in the Ontario Health Technology Assessment Series between 2006 and 2011 was reviewed to identify health technologies that have been effective or cost-effective in helping to manage chronic disease in the community. All technologies identified led to better patient outcomes and less use of health services. Most were also cost-effective. Two technologies that can cure chronic disease and 1 that can prevent chronic disease were found. Eight technologies that can help manage chronic disease were also found. Health technologies should be considered an important part of chronic disease management in the community. PMID:24228075
Tessaris, Daniele; Boyce, Alison M; Zacharin, Margaret; Matarazzo, Patrizia; Lala, Roberto; De Sanctis, Luisa; Collins, Michael T
2018-04-19
In fibrous dysplasia (BFD), normal bone and bone marrow are replaced by fibro-osseous tissue, leading to fracture, deformity and pain. BFD may be isolated, or in association with cutaneous hyperpigmentation and/or hyperfunctioning endocrinopathies, termed McCune-Albright syndrome (MAS). GH hypersecretion has been described in 10%-20% of MAS-BFD patients. Aim of the study was to determine the impact of GH-insulin like growth factor 1 (IGF1) axis hyperactivity on MAS-BFD morbidities and the efficacy of GH excess therapy. A multicentric cross-sectional analysis was conducted on three different MAS cohorts. From 195 MAS patients, 37 subjects (19%) with GH excess were identified and compared with 34 MAS controls without GH hypersecretion. Mean head circumference SDS was significantly higher in GH excess: 4.025 SDS vs 0.683 SDS (P < .0001). The risk of optic neuropathy (Odds ratio 4.231; P = .039), hearing deficit (Odds ratio 2.961; P = .0481), facial asymmetry (Odds ratio 6.563; P = .0192), malignancies (Odds ratio 15.24; P = .0173) were higher in GH excess group. Overall, pharmacotherapy (octreotide alone 10-30 mg/mo or with pegvisomant 10-20 mg/d) was effective in IGF1 normalization (IGF1 Z-score between -2 and +2 SDS) in 21/29 patients (72.4%) with good compliance to the regimen. Late diagnosis and GH excess treatment after 16 years old of age was associated with an increased risk of optic neuropathy (Odds ratio 4.500; P = .0491) and growth of pituitary adenomas (Odds ratio 7.846; P = .050). GH-IGF1 hyperactivity increases risk of morbidities in MAS. Medical therapy is effective in normalizing IGF1 in most patients, and early treatment during paediatric age is associated with a decreased risk of optic neuropathy and GH-secreting adenomas growth. © 2018 John Wiley & Sons Ltd.
SU-F-P-59: Detection of Missing Surgical Needles with Intraoperative Mobile X-Ray
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, L; Berger, B
Purpose: To determine the minimal detectable size of a surgical needle using intraoperative mobile x-ray imaging. Also, varying techniques such as low kVp and high tube current were tested to investigate whether this improved the detection of the various needle sizes. Methods: Seven surgical needle sizes, 6.5, 8, 11, 13, 16, 17 and 19 mm, were positioned on three regions (thoracic, abdominal and pelvic) of an adult size anthropomorphic RANDO phantom. The phantom represents an average size adult. The phantom, in front of detector, was imaged with 44” x-ray tube to detector distance. For the thoracic region, each needle sizemore » was imaged 4 times using the following technique (81 kVp at 32 mAs and 200 mAs; then 100 kVp at 32 mAs and 200 mAs. This was repeated for the abdominal and pelvic regions of the phantom. The images were reviewed by a board certified diagnostic radiologist. Results: The surgical needles sized 13 mm and above were visible at all three body regions using all four kVp and mAs combinations. For surgical needle sizes 8 and 11 mm, the visibility of needle was ambiguous in thoracic region and barely visible abdominal and pelvic regions. Surgical needles, with size smaller than 8 mm, could not be visualized on x-ray with unassisted eyesight. The detectability of the smaller sized needles was not improved with increasing mAs or decreasing kVp. Conclusion: Surgical needle sizes less that 13 mm were not visualized with intraoperative mobile x-ray imaging using various mAs and kVp combinations. Intraoperative mobile x-ray is not recommended to locate surgical needle sizes less than 13 mm for the following reasons: (1) it prevents unnecessary radiation exposure to patient, (2) it avoids the delay time with wound closure and completion of the operative procedure, and (3) it saves radiologist reading time.« less
Mastoparan-Induced Intracellular Ca2+ Fluxes May Regulate Cell-to-Cell Communication in Plants.
Tucker, E. B.; Boss, W. F.
1996-06-01
The relationship of Ca2+ and plasmodesmatal closure was examined in staminal hairs of Setcreasea purpurea by microinjecting cells with active mastoparan (Mas-7), inactive mastoparan (Mas-17), active inositol-1,4,5-trisphosphate (IP3), or inactive IP3. Calcium green dextran 10,000 was used to study cellular free Ca2+, and carboxyfluorescein was used to monitor plasmodesmatal closure. When Mas-7 was microinjected into the cytoplasm of cell 1 (the tip cell of a chain of cells), a rapid increase in calcium green dextran-10,000 fluorescence was observed in the cytoplasmic areas on both sides of the plasmodesmata connecting cells 1 and 2 during the same time that the diffusion of carboxyfluorescein through them was blocked. The inhibition of cell-to-cell diffusion was transient, and the closed plasmodesmata reopened within 30 s. The elevated Ca2+ level near plasmodesmata was also transient and returned to base level in about 1.5 min. The transient increase in Ca2+, once initiated in cell 1, repeated with an oscillatory period of 3 min. Elevated Ca2+ and oscillations of Ca2+ were also observed near interconnecting cell walls throughout the chain of cells, indicating that the signal had been transmitted. Previously, we reported that IP3 closed plasmodesmata; now we report that it stimulated Ca2+ and oscillations similar to Mas-7. The effect was specific for similar concentrations of Mas-7 over Mas-17 and active IP3 over inactive IP3. It is important that the Ca2+ channel blocker La3+ eliminated the responses from Mas-7 and IP3, indicating that an influx of Ca2+ was required. These results support the contention that plasmodesmata functioning is regulated via Ca2+ and that IP3 may be an intermediary between the stimulus and Ca2+ elevations.
Mastoparan-Induced Intracellular Ca2+ Fluxes May Regulate Cell-to-Cell Communication in Plants.
Tucker, E. B.; Boss, W. F.
1996-01-01
The relationship of Ca2+ and plasmodesmatal closure was examined in staminal hairs of Setcreasea purpurea by microinjecting cells with active mastoparan (Mas-7), inactive mastoparan (Mas-17), active inositol-1,4,5-trisphosphate (IP3), or inactive IP3. Calcium green dextran 10,000 was used to study cellular free Ca2+, and carboxyfluorescein was used to monitor plasmodesmatal closure. When Mas-7 was microinjected into the cytoplasm of cell 1 (the tip cell of a chain of cells), a rapid increase in calcium green dextran-10,000 fluorescence was observed in the cytoplasmic areas on both sides of the plasmodesmata connecting cells 1 and 2 during the same time that the diffusion of carboxyfluorescein through them was blocked. The inhibition of cell-to-cell diffusion was transient, and the closed plasmodesmata reopened within 30 s. The elevated Ca2+ level near plasmodesmata was also transient and returned to base level in about 1.5 min. The transient increase in Ca2+, once initiated in cell 1, repeated with an oscillatory period of 3 min. Elevated Ca2+ and oscillations of Ca2+ were also observed near interconnecting cell walls throughout the chain of cells, indicating that the signal had been transmitted. Previously, we reported that IP3 closed plasmodesmata; now we report that it stimulated Ca2+ and oscillations similar to Mas-7. The effect was specific for similar concentrations of Mas-7 over Mas-17 and active IP3 over inactive IP3. It is important that the Ca2+ channel blocker La3+ eliminated the responses from Mas-7 and IP3, indicating that an influx of Ca2+ was required. These results support the contention that plasmodesmata functioning is regulated via Ca2+ and that IP3 may be an intermediary between the stimulus and Ca2+ elevations. PMID:12226302
Role of Mas receptor in renal blood flow response to angiotensin (1-7) in male and female rats.
Nematbakhsh, Mehdi; Safari, Tahereh
2014-01-01
Epidemiologic and clinical studies have shown that progression of renal disease in male is faster than that in female. However, the exact mechanisms are not well recognized. Angiotensin (1-7) (Ang 1-7) receptor, called "Mas", is an element in the depressor arm of renin angiotensin system (RAS), and its expression is enhanced in females. We test the hypothesis that Mas receptor (MasR) blockade (A779) attenuates renal blood flow (RBF) in response to infusion of graded doses of Ang 1-7 in female rats. Male and female Wistar rats were anesthetized and catheterized. Then, the mean arterial pressure (MAP), RBF, and controlled renal perfusion pressure (RPP) responses to infusion of graded doses of Ang 1-7 (100-1000 ng/kg/min i.v.) with and without A779 were measured in the animals. Basal MAP, RPP, RBF, and renal vascular resistance (RVR) were not significantly different between the two groups. After Ang 1-7 administration, RPP was controlled at a constant level. However, RBF increased in a dose-related manner in response to Ang 1-7 infusion in both male and female rats (Pdose<0.0001), but masR blockade significantly attenuated this response only in female (Pgroup=0.04) and not male (Pgroup=0.23). In addition, A779 increased the RBF response to Ang 1-7 to a greater extent. This is while the increase in male was not significant when compared with that in female (Pgender=0.08). RVR response to Ang 1-7 was insignificantly attenuated by A779 in both genders. The masR differently regulated RBF response to Ang 1-7 in the two genders, and the effect was greater in female rats. The masR may be a target for improvement of kidney circulation in renal diseases.
NASA Technical Reports Server (NTRS)
Chiriaco, M.; Chepfer, H.; Haeffelin, M.; Minnis, P.; Noel, V.; Platnick, S.; McGill, M.; Baumgardner, D.; Dubuisson, P.; Pelon, J.;
2007-01-01
This study compares cirrus particle effective radius retrieved by a CALIPSO-like method with two similar methods using MODIS, MODI Airborne Simulator (MAS), and GOES imagery. The CALIPSO-like method uses lidar measurements coupled with the split-window technique that uses the infrared spectral information contained at the 8.65-micrometer, 11.15-micrometer and 12.05-micrometer bands to infer the microphysical properties of cirrus clouds. The two other methods, sing passive remote sensing at visible and infrared wavelengths, are the operational MODIS cloud products (referred to by its archival product identifier MOD06 for MODIS Terra) and MODIS retrievals performed by the CERES team at LaRC (Langley Research Center) in support of CERES algorithms; the two algorithms will be referred to as MOD06- and LaRC-method, respectively. The three techniques are compared at two different latitudes: (i) the mid-latitude ice clouds study uses 18 days of observations at the Palaiseau ground-based site in France (SIRTA: Site Instrumental de Recherche par Teledetection Atmospherique) including a ground-based 532 nm lidar and the Moderate Resolution Imaging Spectrometer (MODIS) overpasses on the Terra Platform, (ii) the tropical ice clouds study uses 14 different flight legs of observations collected in Florida, during the intensive field experiment CRYSTAL-FACE (Cirrus Regional Study of Tropical Anvils and cirrus Layers-Florida Area Cirrus Experiment), including the airborne Cloud Physics Lidar (CPL) and the MAS. The comparison of the three methods gives consistent results for the particle effective radius and the optical thickness, but discrepancies in cloud detection and altitudes. The study confirms the value of an active remote-sensing method (CALIPSO-like) for the study of sub-visible ice clouds, in both mid-latitudes and tropics. Nevertheless, this method is not reliable in optically very thick tropical ice clouds.
RNA Characterization by Solid-State NMR Spectroscopy.
Yang, Yufei; Wang, Shenlin
2018-06-21
The structures of RNAs, which play critical roles in various biological processes, provide important clues and insights into the biological functions of these molecules. However, RNA structure determination remains a challenging topic. In recent years, magic-angle-spinning solid-state NMR (MAS SSNMR) has emerged as an alternative technique for structural and dynamic characterization of RNA. MAS SSNMR has been successfully applied to provide atomic-level structural information about several RNA molecules and RNA-protein complexes. In this Minireview, we give an overview of recent progress in the field of MAS SSNMR based RNA structural characterization, and introduce sample preparation strategies and SSNMR spectroscopic techniques that have been incorporated to identify RNA structural elements. We also highlight a few impressive examples of RNAs that have been investigated extensively by SSNMR. Finally, we briefly discuss future technical trends in the use of MAS SSNMR to facilitate RNA structure determination. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Cross-validating a bidimensional mathematics anxiety scale.
Haiyan Bai
2011-03-01
The psychometric properties of a 14-item bidimensional Mathematics Anxiety Scale-Revised (MAS-R) were empirically cross-validated with two independent samples consisting of 647 secondary school students. An exploratory factor analysis on the scale yielded strong construct validity with a clear two-factor structure. The results from a confirmatory factor analysis indicated an excellent model-fit (χ(2) = 98.32, df = 62; normed fit index = .92, comparative fit index = .97; root mean square error of approximation = .04). The internal consistency (.85), test-retest reliability (.71), interfactor correlation (.26, p < .001), and positive discrimination power indicated that MAS-R is a psychometrically reliable and valid instrument for measuring mathematics anxiety. Math anxiety, as measured by MAS-R, correlated negatively with student achievement scores (r = -.38), suggesting that MAS-R may be a useful tool for classroom teachers and other educational personnel tasked with identifying students at risk of reduced math achievement because of anxiety.
Baylis, Kathy; Hoover, Shelley E.; Currie, Rob W.; Melathopoulos, Andony P.; Pernal, Stephen F.; Foster, Leonard J.; Guarna, M. Marta
2017-01-01
Abstract Over the past decade in North America and Europe, winter losses of honey bee (Hymenoptera: Apidae) colonies have increased dramatically. Scientific consensus attributes these losses to multifactorial causes including altered parasite and pathogen profiles, lack of proper nutrition due to agricultural monocultures, exposure to pesticides, management, and weather. One method to reduce colony loss and increase productivity is through selective breeding of queens to produce disease-, pathogen-, and mite-resistant stock. Historically, the only method for identifying desirable traits in honey bees to improve breeding was through observation of bee behavior. A team of Canadian scientists have recently identified markers in bee antennae that correspond to behavioral traits in bees and can be tested for in a laboratory. These scientists have demonstrated that this marker-assisted selection (MAS) can be used to produce hygienic, pathogen-resistant honey bee colonies. Based on this research, we present a beekeeping case study where a beekeeper’s profit function is used to evaluate the economic impact of adopting colonies selected for hygienic behavior using MAS into an apiary. Our results show a net profit gain from an MAS colony of between 2% and 5% when Varroa mites are effectively treated. In the case of ineffective treatment, MAS generates a net profit benefit of between 9% and 96% depending on the Varroa load. When a Varroa mite population has developed some treatment resistance, we show that MAS colonies generate a net profit gain of between 8% and 112% depending on the Varroa load and degree of treatment resistance. PMID:28334400
Advanced fitness landscape analysis and the performance of memetic algorithms.
Merz, Peter
2004-01-01
Memetic algorithms (MAs) have demonstrated very effective in combinatorial optimization. This paper offers explanations as to why this is so by investigating the performance of MAs in terms of efficiency and effectiveness. A special class of MAs is used to discuss efficiency and effectiveness for local search and evolutionary meta-search. It is shown that the efficiency of MAs can be increased drastically with the use of domain knowledge. However, effectiveness highly depends on the structure of the problem. As is well-known, identifying this structure is made easier with the notion of fitness landscapes: the local properties of the fitness landscape strongly influence the effectiveness of the local search while the global properties strongly influence the effectiveness of the evolutionary meta-search. This paper also introduces new techniques for analyzing the fitness landscapes of combinatorial problems; these techniques focus on the investigation of random walks in the fitness landscape starting at locally optimal solutions as well as on the escape from the basins of attractions of current local optima. It is shown for NK-landscapes and landscapes of the unconstrained binary quadratic programming problem (BQP) that a random walk to another local optimum can be used to explain the efficiency of recombination in comparison to mutation. Moreover, the paper shows that other aspects like the size of the basins of attractions of local optima are important for the efficiency of MAs and a local search escape analysis is proposed. These simple analysis techniques have several advantages over previously proposed statistical measures and provide valuable insight into the behaviour of MAs on different kinds of landscapes.
NASA Astrophysics Data System (ADS)
Puzi, A. Ahmad; Sidek, S. N.; Mat Rosly, H.; Daud, N.; Yusof, H. Md
2017-11-01
Spasticity is common symptom presented amongst people with sensorimotor disabilities. Imbalanced signals from the central nervous systems (CNS) which are composed of the brain and spinal cord to the muscles ultimately leading to the injury and death of motor neurons. In clinical practice, the therapist assesses muscle spasticity using a standard assessment tool like Modified Ashworth Scale (MAS), Modified Tardiue Scale (MTS) or Fugl-Meyer Assessment (FMA). This is done subjectively based on the experience and perception of the therapist subjected to the patient fatigue level and body posture. However, the inconsistency in the assessment is prevalent and could affect the efficacy of the rehabilitation process. Thus, the aim of this paper is to describe the methodology of data collection and the quantitative model of MAS developed to satisfy its description. Two subjects with MAS of 2 and 3 spasticity levels were involved in the clinical data measurement. Their level of spasticity was verified by expert therapist using current practice. Data collection was established using mechanical system equipped with data acquisition system and LABVIEW software. The procedure engaged repeated series of flexion of the affected arm that was moved against the platform using a lever mechanism and performed by the therapist. The data was then analyzed to investigate the characteristics of spasticity signal in correspondence to the MAS description. Experimental results revealed that the methodology used to quantify spasticity satisfied the MAS tool requirement according to the description. Therefore, the result is crucial and useful towards the development of formal spasticity quantification model.
Clinical analysis of macrophage activation syndrome in pediatric patients with autoimmune diseases.
Lin, Cheng-I; Yu, Hsin-Hui; Lee, Jyh-Hong; Wang, Li-Chieh; Lin, Yu-Tsan; Yang, Yao-Hsu; Chiang, Bor-Luen
2012-08-01
Macrophage activation syndrome (MAS) belongs to secondary hemophagocytic lymphohistiocytosis (HLH) syndrome. It is usually associated with rheumatic diseases. We retrospectively reviewed our hospital's medical records of 102 HLH/MAS patients from the past 20 years. Demographics, clinical data, treatment, and outcomes were analyzed. Among 102 patients, eight patients with underlying juvenile systemic lupus erythematous (two patients), mixed connective tissue disease (one patient), primary anti-phospholipid syndrome (one patient), and systemic type juvenile rheumatoid arthritis (sJRA; four patients) with 13 episodes of MAS were studied. Clinical manifestations of MAS included fever (100 %), hepatosplenomegaly (77 %), lymphadenopathy (38 %), skin rash (62 %), and neurological involvement (31 %). Laboratory features included leukopenia (54 %), anemia (46 %), thrombocytopenia (77 %), jaundice (27 %), hypofibrinogenemia (40 %), decreased erythrocyte sedimentation rate (67 %), and elevated liver enzymes (77 %), lactate dehydrogenase (100 %), ferritin (88 %), triglycerides (91 %), C-reactive protein (85 %), plasma D-dimer (50 %), and hemophagocytosis in bone marrow (83 %). The Epstein-Barr virus and adenovirus infection triggered MAS in two patients with sJRA. Methylprednisolone pulse therapy was effective in two out of three patients, and high-dose intravenous immunoglobulin (IVIG) was effective in two out of six patients. Patients with sJRA responded well to corticosteroids and cyclosporine. Complications included opportunistic infection with Pneumocystis jiroveci, multiple organ failure, and intensive care unit myopathy. The mortality rate was one out of eight (12.5 %). Our results showed that MAS could be fatal and complicate various pediatric autoimmune diseases. It generally has a good response to corticosteroids and IVIG. Prompt recognition and timely treatment can result in good outcomes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Merkin, V. G.; Lionello, R.; Linker, J.
2016-11-01
Two well-established magnetohydrodynamic (MHD) codes are coupled to model the solar corona and the inner heliosphere. The corona is simulated using the MHD algorithm outside a sphere (MAS) model. The Lyon–Fedder–Mobarry (LFM) model is used in the heliosphere. The interface between the models is placed in a spherical shell above the critical point and allows both models to work in either a rotating or an inertial frame. Numerical tests are presented examining the coupled model solutions from 20 to 50 solar radii. The heliospheric simulations are run with both LFM and the MAS extension into the heliosphere, and use themore » same polytropic coronal MAS solutions as the inner boundary condition. The coronal simulations are performed for idealized magnetic configurations, with an out-of-equilibrium flux rope inserted into an axisymmetric background, with and without including the solar rotation. The temporal evolution at the inner boundary of the LFM and MAS solutions is shown to be nearly identical, as are the steady-state background solutions, prior to the insertion of the flux rope. However, after the coronal mass ejection has propagated through the significant portion of the simulation domain, the heliospheric solutions diverge. Additional simulations with different resolution are then performed and show that the MAS heliospheric solutions approach those of LFM when run with progressively higher resolution. Following these detailed tests, a more realistic simulation driven by the thermodynamic coronal MAS is presented, which includes solar rotation and an azimuthally asymmetric background and extends to the Earth’s orbit.« less
caCORRECT2: Improving the accuracy and reliability of microarray data in the presence of artifacts
2011-01-01
Background In previous work, we reported the development of caCORRECT, a novel microarray quality control system built to identify and correct spatial artifacts commonly found on Affymetrix arrays. We have made recent improvements to caCORRECT, including the development of a model-based data-replacement strategy and integration with typical microarray workflows via caCORRECT's web portal and caBIG grid services. In this report, we demonstrate that caCORRECT improves the reproducibility and reliability of experimental results across several common Affymetrix microarray platforms. caCORRECT represents an advance over state-of-art quality control methods such as Harshlighting, and acts to improve gene expression calculation techniques such as PLIER, RMA and MAS5.0, because it incorporates spatial information into outlier detection as well as outlier information into probe normalization. The ability of caCORRECT to recover accurate gene expressions from low quality probe intensity data is assessed using a combination of real and synthetic artifacts with PCR follow-up confirmation and the affycomp spike in data. The caCORRECT tool can be accessed at the website: http://cacorrect.bme.gatech.edu. Results We demonstrate that (1) caCORRECT's artifact-aware normalization avoids the undesirable global data warping that happens when any damaged chips are processed without caCORRECT; (2) When used upstream of RMA, PLIER, or MAS5.0, the data imputation of caCORRECT generally improves the accuracy of microarray gene expression in the presence of artifacts more than using Harshlighting or not using any quality control; (3) Biomarkers selected from artifactual microarray data which have undergone the quality control procedures of caCORRECT are more likely to be reliable, as shown by both spike in and PCR validation experiments. Finally, we present a case study of the use of caCORRECT to reliably identify biomarkers for renal cell carcinoma, yielding two diagnostic biomarkers with potential clinical utility, PRKAB1 and NNMT. Conclusions caCORRECT is shown to improve the accuracy of gene expression, and the reproducibility of experimental results in clinical application. This study suggests that caCORRECT will be useful to clean up possible artifacts in new as well as archived microarray data. PMID:21957981
Fattoretti, Patrizia; Malatesta, Manuela; Cisterna, Barbara; Milanese, Chiara; Zancanaro, Carlo
2018-01-01
Aerobic physical exercise (APE) leads to improved brain functions. To better understand the beneficial effect of APE on the aging brain, a morphometric study was carried out of changes in hippocampal synapses of old (>27 months) Balb/c mice undergoing treadmill training (OTT) for 4 weeks in comparison with old sedentary (OS), middle-aged sedentary (MAS) and middle-aged treadmill training (MATT) mice. The inner molecular layer of the hippocampal dentate gyrus (IMLDG) and the molecular stratum of Ammon's horn1 neurons (SMCA1) were investigated. The number of synapses per cubic micron of tissue (numeric density, Nv), overall synaptic area per cubic micron of tissue (surface density, Sv), average area of synaptic contact zones (S), and frequency (%) of perforated synapses (PS) were measured in electron micrographs of ethanol-phosphotungstic acid (E-PTA) stained tissue. Data were analyzed with analysis of variance (ANOVA). In IMLDG, an effect of age was found for Nv and Sv, but not S and %PS. Similar results were found for exercise and the interaction of age and exercise. In post hoc analysis Nv was higher (60.6% to 75.1%; p < 0.001) in MATT vs. MAS, OS and OTT. Sv was higher (32.3% to 54.6%; p < 0.001) in MATT vs. MAS, OS and OTT. In SMCA1, age affected Nv, Sv and %PS, but not S. The effect of exercise was significant for Sv only. The interaction of age and exercise was significant for Nv, Sv and %PS. In post hoc analysis Nv was lower in OS vs. MAS, MATT and OTT (-26.1% to -32.1%; p < 0.038). MAS and OTT were similar. Sv was lower in OS vs. MAS, MATT and OTT (-23.4 to -30.3%, p < 0.004). MAS and OTT were similar. PS frequency was higher in OS vs. MAS, MATT and OTT (48.3% to +96.6%, p < 0.023). APE positively modulated synaptic structural dynamics in the aging hippocampus, possibly in a region-specific way. The APE-associated reduction in PS frequency in SMCA1 of old mice suggests that an increasing complement of PS is a compensatory phenomenon to maintain synaptic efficacy. In conclusion, the modulation of synaptic plasticity by APE gives quantitative support to the concept that APE protects from neurodegeneration and improves learning and memory in aging.
VLTI-GRAVITY measurements of cool evolved stars
NASA Astrophysics Data System (ADS)
Wittkowski, M.; Rau, G.; Chiavassa, A.; Höfner, S.; Scholz, M.; Wood, P. R.; de Wit, W. J.; Eisenhauer, F.; Haubois, X.; Paumard, T.
2018-06-01
Context. Dynamic model atmospheres of Mira stars predict variabilities in the photospheric radius and in atmospheric molecular layers which are not yet strongly constrained by observations. Aims: Here we measure the variability of the oxygen-rich Mira star R Peg in near-continuum and molecular bands. Methods: We used near-infrared K-band spectro-interferometry with a spectral resolution of about 4000 obtained at four epochs between post-maximum and minimum visual phases employing the newly available GRAVITY beam combiner at the Very Large Telescope Interferometer (VLTI). Results: Our observations show a continuum radius that is anti-correlated with the visual lightcurve. Uniform disc (UD) angular diameters at a near-continuum wavelength of 2.25 μm are steadily increasing with values of 8.7 ± 0.1 mas, 9.4 ± 0.1 mas, 9.8 ± 0.1 mas, and 9.9 ± 0.1 mas at visual phases of 0.15, 0.36, 0,45, 0.53, respectively. UD diameters at a bandpass around 2.05 μm, dominated by water vapour, follow the near-continuum variability at larger UD diameters between 10.7 mas and 11.7 mas. UD diameters at the CO 2-0 bandhead, instead, are correlated with the visual lightcurve and anti-correlated with the near-continuum UD diameters, with values between 12.3 mas and 11.7 mas. Conclusions: The observed anti-correlation between continuum radius and visual lightcurve is consistent with an earlier study of the oxygen-rich Mira S Lac, and with recent 1D CODEX dynamic model atmosphere predictions. The amplitude of the variation is comparable to the earlier observations of S Lac, and smaller than predicted by CODEX models. The wavelength-dependent visibility variations at our epochs can be reproduced by a set of CODEX models at model phases between 0.3 and 0.6. The anti-correlation of water vapour and CO contributions at our epochs suggests that these molecules undergo different processes in the extended atmosphere along the stellar cycle. The newly available GRAVITY instrument is suited to conducting longer time series observations, which are needed to provide strong constraints on the model-predicted intra- and inter-cycle variability. Based on observations made with the VLT Interferometer at Paranal Observatory under programme IDs 60.A-9176 and 098.D-0647.
Quality assessment for color reproduction using a blind metric
NASA Astrophysics Data System (ADS)
Bringier, B.; Quintard, L.; Larabi, M.-C.
2007-01-01
This paper deals with image quality assessment. This field plays nowadays an important role in various image processing applications. Number of objective image quality metrics, that correlate or not, with the subjective quality have been developed during the last decade. Two categories of metrics can be distinguished, the first with full-reference and the second with no-reference. Full-reference metric tries to evaluate the distortion introduced to an image with regards to the reference. No-reference approach attempts to model the judgment of image quality in a blind way. Unfortunately, the universal image quality model is not on the horizon and empirical models established on psychophysical experimentation are generally used. In this paper, we focus only on the second category to evaluate the quality of color reproduction where a blind metric, based on human visual system modeling is introduced. The objective results are validated by single-media and cross-media subjective tests.
The quality of veterinary in-clinic and reference laboratory biochemical testing.
Rishniw, Mark; Pion, Paul D; Maher, Tammy
2012-03-01
Although evaluation of biochemical analytes in blood is common in veterinary practice, studies assessing the global quality of veterinary in-clinic and reference laboratory testing have not been reported. The aim of this study was to assess the quality of biochemical testing in veterinary laboratories using results obtained from analyses of 3 levels of assayed quality control materials over 5 days. Quality was assessed by comparison of calculated total error with quality requirements, determination of sigma metrics, use of a quality goal index to determine factors contributing to poor performance, and agreement between in-clinic and reference laboratory mean results. The suitability of in-clinic and reference laboratory instruments for statistical quality control was determined using adaptations from the computerized program, EZRules3. Reference laboratories were able to achieve desirable quality requirements more frequently than in-clinic laboratories. Across all 3 materials, > 50% of in-clinic analyzers achieved a sigma metric ≥ 6.0 for measurement of 2 analytes, whereas > 50% of reference laboratory analyzers achieved a sigma metric ≥ 6.0 for measurement of 6 analytes. Expanded uncertainty of measurement and ± total allowable error resulted in the highest mean percentages of analytes demonstrating agreement between in-clinic and reference laboratories. Owing to marked variation in bias and coefficient of variation between analyzers of the same and different types, the percentages of analytes suitable for statistical quality control varied widely. These findings reflect the current state-of-the-art with regard to in-clinic and reference laboratory analyzer performance and provide a baseline for future evaluations of the quality of veterinary laboratory testing. © 2012 American Society for Veterinary Clinical Pathology.
48 CFR 538.270 - Evaluation of multiple award schedule (MAS) offers.
Code of Federal Regulations, 2010 CFR
2010-10-01
... SERVICES ADMINISTRATION SPECIAL CATEGORIES OF CONTRACTING FEDERAL SUPPLY SCHEDULE CONTRACTING Establishing and Administering Federal Supply Schedules 538.270 Evaluation of multiple award schedule (MAS) offers... determining the Government's price negotiation objectives, consider the following factors: (1) Aggregate...
NASA Technical Reports Server (NTRS)
Filho, Aluzio Haendehen; Caminada, Numo; Haeusler, Edward Hermann; vonStaa, Arndt
2004-01-01
To support the development of flexible and reusable MAS, we have built a framework designated MAS-CF. MAS-CF is a component framework that implements a layered architecture based on contextual composition. Interaction rules, controlled by architecture mechanisms, ensure very low coupling, making possible the sharing of distributed services in a transparent, dynamic and independent way. These properties propitiate large-scale reuse, since organizational abstractions can be reused and propagated to all instances created from a framework. The objective is to reduce complexity and development time of multi-agent systems through the reuse of generic organizational abstractions.
Product Distribution Theory and Semi-Coordinate Transformations
NASA Technical Reports Server (NTRS)
Airiau, Stephane; Wolpert, David H.
2004-01-01
Product Distribution (PD) theory is a new framework for doing distributed adaptive control of a multiagent system (MAS). We introduce the technique of "coordinate transformations" in PD theory gradient descent. These transformations selectively couple a few agents with each other into "meta-agents". Intuitively, this can be viewed as a generalization of forming binding contracts between those agents. Doing this sacrifices a bit of the distributed nature of the MAS, in that there must now be communication from multiple agents in determining what joint-move is finally implemented However, as we demonstrate in computer experiments, these transformations improve the performance of the MAS.
Matsubara, Kosuke; Koshida, Kichiro; Suzuki, Masayuki; Hayakawa, Mayumi; Tsujii, Hideo; Yamamoto, Tomoyuki
2005-12-20
Excessive radiation exposure in pediatric computed tomography (CT) scanning has become a serious problem, and it is difficult to select scan parameters for the scanning of small patients such as children. We investigated differences in absorbed dose and standard deviation (SD) in Hounsfield unit (HU) caused by differences in the form of the subject using a body-type phantom with removable body parts. Using four X-ray CT scanners, measurements were made with values from 50 mAs to 300 mAs, with slices of 50 mAs, using scan protocols that were assumed to perform thorough examinations. The results showed that the mAs values and absorbed doses were almost proportional, and the absorbed doses in the phantom without body parts were about 1.1-2.2-fold higher than those of the phantom with body parts at the same points. The SD values obtained indicated that the absorbed doses in the phantom with body parts were 0.3-0.6 times those of the phantom without body parts when the mAs values used were adjusted so that both SD values were the same. The absorbed doses in various patient forms can be estimated from these results, and they will become critical data for the selection of appropriate scan protocols.
Contreras, Laura; Satrústegui, Jorgina
2009-03-13
Ca2+ signaling in mitochondria has been mainly attributed to Ca2+ entry to the matrix through the Ca2+ uniporter and activation of mitochondrial matrix dehydrogenases. However, mitochondria can also sense increases in cytosolic Ca2+ through a mechanism that involves the aspartate-glutamate carriers, extramitochondrial Ca2+ activation of the NADH malate-aspartate shuttle (MAS). Both pathways are linked through the shared substrate alpha-ketoglutarate (alphaKG). Here we have studied the interplay between the two pathways under conditions of Ca2+ activation. We show that alphaKG becomes limiting when Ca2+ enters in brain or heart mitochondria, but not liver mitochondria, resulting in a drop in alphaKG efflux through the oxoglutarate carrier and in a drop in MAS activity. Inhibition of alphaKG efflux and MAS activity by matrix Ca2+ in brain mitochondria was fully reversible upon Ca2+ efflux. Because of their differences in cytosolic calcium concentration requirements, the MAS and Ca2+ uniporter-mitochondrial dehydrogenase pathways are probably sequentially activated during a Ca2+ transient, and the inhibition of MAS at the center of the transient may provide an explanation for part of the increase in lactate observed in the stimulated brain in vivo.
Automated detection of microaneurysms using robust blob descriptors
NASA Astrophysics Data System (ADS)
Adal, K.; Ali, S.; Sidibé, D.; Karnowski, T.; Chaum, E.; Mériaudeau, F.
2013-03-01
Microaneurysms (MAs) are among the first signs of diabetic retinopathy (DR) that can be seen as round dark-red structures in digital color fundus photographs of retina. In recent years, automated computer-aided detection and diagnosis (CAD) of MAs has attracted many researchers due to its low-cost and versatile nature. In this paper, the MA detection problem is modeled as finding interest points from a given image and several interest point descriptors are introduced and integrated with machine learning techniques to detect MAs. The proposed approach starts by applying a novel fundus image contrast enhancement technique using Singular Value Decomposition (SVD) of fundus images. Then, Hessian-based candidate selection algorithm is applied to extract image regions which are more likely to be MAs. For each candidate region, robust low-level blob descriptors such as Speeded Up Robust Features (SURF) and Intensity Normalized Radon Transform are extracted to characterize candidate MA regions. The combined features are then classified using SVM which has been trained using ten manually annotated training images. The performance of the overall system is evaluated on Retinopathy Online Challenge (ROC) competition database. Preliminary results show the competitiveness of the proposed candidate selection techniques against state-of-the art methods as well as the promising future for the proposed descriptors to be used in the localization of MAs from fundus images.
Valadares, Agnes Araujo; Duarte, Paulo Schiavom; Woellner, Eduardo Bechtloff; Coura-Filho, George Barberio; Sapienza, Marcelo Tatit; Buchpiguel, Carlos Alberto
2015-01-01
To analyze standardized uptake values (SUVs) using three different tube current intensities for attenuation correction on (18)FNaF PET/CT scans. A total of 254 (18)F-NaF PET/CT studies were analyzed using 10, 20 and 30 mAs. The SUVs were calculated in volumes of interest (VOIs) drawn on three skeletal regions, namely, right proximal humeral diaphysis (RH), right proximal femoral diaphysis (RF), and first lumbar vertebra (LV1) in a total of 712 VOIs. The analyses covered 675 regions classified as normal (236 RH, 232 RF, and 207 LV1). Mean SUV for each skeletal region was 3.8, 5.4 and 14.4 for RH, RF, and LV1, respectively. As the studies were grouped according to mAs value, the mean SUV values were 3.8, 3.9 and 3.7 for 10, 20 and 30 mAs, respectively, in the RH region; 5.4, 5.5 and 5.4 for 10, 20 and 30 mAs, respectively, in the RF region; 13.8, 14.9 and 14.5 for 10, 20 and 30 mAs, respectively, in the LV1 region. The three tube current values yielded similar results for SUV calculation.
Psoralen-induced DNA adducts are substrates for the base excision repair pathway in human cells
Couvé-Privat, Sophie; Macé, Gaëtane; Saparbaev, Murat K.
2007-01-01
Interstrand cross-link (ICL) is a covalent modification of both strands of DNA, which prevents DNA strand separation during transcription and replication. Upon photoactivation 8-methoxypsoralen (8-MOP+UVA) alkylates both strands of DNA duplex at the 5,6-double bond of thymidines, generating monoadducts (MAs) and ICLs. It was thought that bulky DNA lesions such as MAs are eliminated only in the nucleotide excision repair pathway. Instead, non-bulky DNA lesions are substrates for DNA glycosylases and AP endonucleases which initiate the base excision repair (BER) pathway. Here we examined whether BER might be involved in the removal of psoralen–DNA photoadducts. The results show that in human cells DNA glycosylase NEIL1 excises the MAs in duplex DNA, subsequently the apurinic/apyrimidinic endonuclease 1, APE1, removes the 3′-phosphate residue at single-strand break generated by NEIL1. The apparent kinetic parameters suggest that NEIL1 excises MAs with high efficiency. Consistent with these results HeLa cells lacking APE1 and/or NEIL1 become hypersensitive to 8-MOP+UVA exposure. Furthermore, we demonstrate that bacterial homologues of NEIL1, the Fpg and Nei proteins, also excise MAs. New substrate specificity of the Fpg/Nei protein family provides an alternative repair pathway for ICLs and bulky DNA damage. PMID:17715144
Meta-Analyses and Orthodontic Evidence-Based Clinical Practice in the 21st Century
Papadopoulos, Moschos A.
2010-01-01
Introduction: Aim of this systematic review was to assess the orthodontic related issues which currently provide the best evidence as documented by meta-analyses, by critically evaluating and discussing the methodology used in these studies. Material and Methods: Several electronic databases were searched and handsearching was also performed in order to identify the corresponding meta-analyses investigating orthodontic related subjects. In total, 197 studies were retrieved initially. After applying specific inclusion and exclusion criteria, 27 articles were identified as meta-analyses treating orthodontic-related subjects. Results: Many of these 27 papers presented sufficient quality and followed appropriate meta-analytic approaches to quantitatively synthesize data and presented adequately supported evidence. However, the methodology used in some of them presented weaknesses, limitations or deficiencies. Consequently, the topics in orthodontics which currently provide the best evidence, include some issues related to Class II or Class III treatment, treatment of transverse problems, external apical root resorption, dental anomalies, such as congenital missing teeth and tooth transposition, frequency of severe occlusal problems, nickel hypersensitivity, obstructive sleep apnea syndrome, and computer-assisted learning in orthodontic education. Conclusions: Only a few orthodontic related issues have been so far investigated by means of MAs. In addition, for some of these issues investigated in the corresponding MAs no definite conclusions could be drawn, due to significant methodological deficiencies of these studies. According to this investigation, it can be concluded that at the begin of the 21st century there is evidence for only a few orthodontic related issues as documented by meta-analyses, and more well-conducted high quality research studies are needed to produce strong evidence in order to support evidence-based clinical practice in orthodontics. PMID:21673839
Özkan, Filiz; Zincir, Handan
2017-08-01
To assess the effectiveness of reflexology method upon spasticity and function among children with cerebral palsy who received physiotherapy. A three group, randomised trial with blinded evaluator. Randomization was made sealed and opaque envelopes. 45 children with cerebral palsy who were trained at a Special Education and Rehabilitation Centre. In the reflexology and placebo group; a 20min reflexology was performed twice a week in a total 24 sessions. In the control group; no intervention was done. Before and after the implementation; measurements of the participants were obtained. The data were collected using Gross Motor Function Measure, Modified Ashworth Scale (MAS), Modified Tardieu Scale, Pediatric Functional Independence Scale, Pediatric Quality of Life Scale (PedsQL) and demographic data. A total of 45 children completed the study. The groups were homogeneous at baseline. Between right MAS Gastrocnemius muscle was a difference and right and left Soleus muscles was significant among the groups (p<0.05). Also; there was significant difference in between right and left Tardieu value in the legs; right M. Gastrocnemius V1,V3 and M. Soleus V1, V3 values; p<0.001 and left Gastrocnemius V1 and M. Soleus V1, V3 values; p<0.001. In Gross Motor Function Measure total scores and sitting position; in Pediatric Functional Independence Scale total scores, self-care and communication subscales (p<0.05). But in terms of PedsQL was no statistically significant difference among the groups (p>0.05). Reflexology with physiotherapy reduced spasticity in legs, improved gross motor functions, decreased dependency but led to no change in quality of life. Copyright © 2017 Elsevier Inc. All rights reserved.
Puggina, Anna; Aleksovska, Katina; Buck, Christoph; Burns, Con; Cardon, Greet; Carlin, Angela; Chantal, Simon; Ciarapica, Donatella; Condello, Giancarlo; Coppinger, Tara; Cortis, Cristina; D'Haese, Sara; De Craemer, Marieke; Di Blasio, Andrea; Hansen, Sylvia; Iacoviello, Licia; Issartel, Johann; Izzicupo, Pascal; Jaeschke, Lina; Kanning, Martina; Kennedy, Aileen; Chun Man Ling, Fiona; Luzak, Agnes; Napolitano, Giorgio; Nazare, Julie-Anne; Perchoux, Camille; Pischon, Tobias; Polito, Angela; Sannella, Alessandra; Schulz, Holger; Sohun, Rhoda; Steinbrecher, Astrid; Schlicht, Wolfgang; Ricciardi, Walter; MacDonncha, Ciaran; Capranica, Laura; Boccia, Stefania
2018-02-01
Despite the large number of studies and reviews available, the evidence regarding the policy determinants of physical activity (PA) is inconclusive. This umbrella systematic literature review (SLR) summarizes the current evidence on the policy determinants of PA across the life course, by pooling the results of the available SLRs and meta-analyses (MAs). A systematic online search was conducted on MEDLINE, ISI Web of Science, Scopus and SPORTDiscus databases up to April 2016. SLRs and MAs of observational studies investigating the association between policy determinants of PA and having PA as outcome were considered eligible. The extracted data were assessed based on the importance of the determinants, the strength of evidence and the methodological quality. Fourteen reviews on 27 policy determinants of PA were eligible for this umbrella SLR. The majority of the reviews were of moderate quality. Among children, a clear association between time spent outdoors and PA emerged. Among adults, working hours were negatively associated with PA, though evidence was limited. At the population level, community- and street-scale urban design and land use policies were found to positively support PA levels, but levels of evidences were low. With this umbrella SLR the policy determinants of PA at individual-level and population-level have been summarized and assessed. None of the investigated policy determinants had a convincing level of evidence, and very few had a probable level of evidence. Further research is needed, preferably by using prospective study designs, standardized definitions of PA and objective measurement of PA. © The Author 2017. Published by Oxford University Press on behalf of the European Public Health Association.
FFDM image quality assessment using computerized image texture analysis
NASA Astrophysics Data System (ADS)
Berger, Rachelle; Carton, Ann-Katherine; Maidment, Andrew D. A.; Kontos, Despina
2010-04-01
Quantitative measures of image quality (IQ) are routinely obtained during the evaluation of imaging systems. These measures, however, do not necessarily correlate with the IQ of the actual clinical images, which can also be affected by factors such as patient positioning. No quantitative method currently exists to evaluate clinical IQ. Therefore, we investigated the potential of using computerized image texture analysis to quantitatively assess IQ. Our hypothesis is that image texture features can be used to assess IQ as a measure of the image signal-to-noise ratio (SNR). To test feasibility, the "Rachel" anthropomorphic breast phantom (Model 169, Gammex RMI) was imaged with a Senographe 2000D FFDM system (GE Healthcare) using 220 unique exposure settings (target/filter, kVs, and mAs combinations). The mAs were varied from 10%-300% of that required for an average glandular dose (AGD) of 1.8 mGy. A 2.5cm2 retroareolar region of interest (ROI) was segmented from each image. The SNR was computed from the ROIs segmented from images linear with dose (i.e., raw images) after flat-field and off-set correction. Image texture features of skewness, coarseness, contrast, energy, homogeneity, and fractal dimension were computed from the Premium ViewTM postprocessed image ROIs. Multiple linear regression demonstrated a strong association between the computed image texture features and SNR (R2=0.92, p<=0.001). When including kV, target and filter as additional predictor variables, a stronger association with SNR was observed (R2=0.95, p<=0.001). The strong associations indicate that computerized image texture analysis can be used to measure image SNR and potentially aid in automating IQ assessment as a component of the clinical workflow. Further work is underway to validate our findings in larger clinical datasets.
Mallik, Abul K; Qiu, Hongdeng; Oishi, Tomohiro; Kuwahara, Yutaka; Takafuji, Makoto; Ihara, Hirotaka
2015-07-07
For the first time, we synthesized multiple embedded polar groups (EPGs) containing linear C18 organic phases. The new materials were characterized by elemental analysis, IR spectroscopy, (1)H NMR, diffuse reflectance infrared Fourier transform (DRIFT), solid-state (13)C cross-polarization magic angle spinning (CP/MAS) NMR, suspended-state (1)H NMR, and differential scanning calorimetry (DSC). (29)Si CP/MAS NMR was carried out to investigate the degree of cross-linking of the silane and silane functionality of the modified silica. Solid-state (13)C CP/MAS NMR and suspended-state (1)H NMR spectroscopy indicated a higher alkyl chain order for the phase containing four EPGs than for the phase with three EPGs. To correlate the NMR results with temperature-dependent chromatographic studies, standard reference materials (SRM 869b and SRM 1647e), a column selectivity test mixture for liquid chromatography was employed. A single EPG containing the C18 phase was also prepared in a similar manner to be used as a reference column especially for the separation of basic and polar compounds in reversed-phase liquid chromatography (RPLC) and hydrophilic interaction liquid chromatography (HILIC), respectively. Detailed chromatographic characterization of the new phases was performed in terms of their surface coverage, hydrophobic selectivity, shape selectivity, hydrogen bonding capacity, and ion-exchange capacity at pH 2.7 and 7.6 for RPLC as well as their hydrophilicity, the selectivity for hydrophilic-hydrophobic substituents, the selectivity for the region and configurational differences in hydrophilic substituents, the evaluation of electrostatic interactions, and the evaluation of the acidic-basic nature for HILIC-mode separation. Furthermore, peak shapes for the basic analytes propranolol and amitriptyline were studied as a function of the number of EPGs on the C18 phases in the RPLC. The chromatographic performance of multiple EPGs containing C18 HILIC phases is illustrated by the separation of sulfa drugs, β-blockers, xanthines, nucleic acid bases, nucleosides, and water-soluble vitamins. Both of the phases showed the best performance for the separation of shape-constrained isomers, nonpolar, polar, and basic compounds in RPLC- and HILIC-mode separation of sulfa drugs, and other polar and basic analytes compared to the conventional alkyl phases with and without embedded polar groups and HILIC phases. Surprisingly, one phase would be able to serve the performance of three different types of phases with very high selectivity, and we named this phase the "smart phase". Versatile applications with a single column will reduce the column purchasing cost for the analyst as well as achieve high separation, which is challenging with the commercially available columns.
ERIC Educational Resources Information Center
Miranda, Regina; Scott, Michelle; Hicks, Roger; Wilcox, Holly C.; Munfakh, Jimmie Lou Harris; Shaffer, David
2008-01-01
The study compares psychiatric diagnoses and future suicide attempt outcomes of multiple attempters (MAs), single attempters (SAs) and ideators. The results conclude that MAs strongly predict later suicide attempts and diagnosis than SAs and ideators.
Markelov, M; Bershevits, O
2006-03-01
This paper offers a methodology of an experimentally simple reversed headspace (RHS) analysis for measuring of matrix effects and their use for identification and characterization of condensed matrices such as pharmaceuticals, polymers, chromatographic packing, etc. applicable for both quality control monitoring and research and development investigation. In RHS methods, the matrix is spiked and equilibrated with a mixture of volatile chemicals containing various functional groups (molecular sensor array or MSA mixture). Headspace chromatograms of the same spikes of a sample and an empty vial are compared. Examination of basic headspace theory shows that matrix specific constants (M), rather than partition coefficients (K), can be calculated from the headspace chromatograms and M=(K-1)xbeta, where beta is a degree of matrix volume change during equilibration. Matrix specific constants can be plotted against any property of chemicals (polarity, dielectric constant, solubility parameter, vapor pressure, etc.) or just against a set of consecutive numbers, each representing a chemical in MSA. This plot is, in a sense, a molecular affinity spectrum (MAS) specific for a given matrix at a given temperature and is independent of an instrument. Changes in MAS that correspond to chemicals with a particular functional group give an insight to the type of differences between matrices and may quantitatively define them.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tommasi, J.; Ruggieri, J. M.; Lebrat, J. F.
The latest release (2.1) of the ERANOS code system, using JEF-2.2, JEFF-3.1 and ENDF/B-VI r8 multigroup cross-section libraries is currently being validated on fast reactor critical experiments at CEA-Cadarache (France). This paper briefly presents the library effect studies and the detailed best-estimate validation studies performed up to now as part of the validation process. The library effect studies are performed over a wide range of experimental configurations, using simple model and method options. They yield global trends about the shift from JEF-2.2 to JEFF-3.1 cross-section libraries, that can be related to individual sensitivities and cross-section changes. The more detailed, best-estimate,more » calculations have been performed up to now over three experimental configurations carried out in the MASURCA critical facility at CEA-Cadarache: two cores with a softened spectrum due to large amounts of graphite (MAS1A' and MAS1B), and a core representative of sodium-cooled fast reactors (CIRANO ZONA2A). Calculated values have been compared to measurements, and discrepancies analyzed in detail using perturbation theory. Values calculated with JEFF-3.1 were found to be within 3 standard deviations of the measured values, and at least of the same quality as the JEF-2.2 based results. (authors)« less
Disease Beyond the Arch: A Systematic Review of Middle Aortic Syndrome in Childhood.
Rumman, Rawan K; Nickel, Cheri; Matsuda-Abedini, Mina; Lorenzo, Armando J; Langlois, Valerie; Radhakrishnan, Seetha; Amaral, Joao; Mertens, Luc; Parekh, Rulan S
2015-07-01
Middle aortic syndrome (MAS) is a rare clinical entity in childhood, characterized by a severe narrowing of the distal thoracic and/or abdominal aorta, and associated with significant morbidity and mortality. MAS remains a relatively poorly defined disease. This paper systematically reviews the current knowledge on MAS with respect to etiology, clinical impact, and therapeutic options. A systematic search of 3 databases (Embase, MEDLINE, and Cochrane Central Register of Controlled Trials) yielded 1,252 abstracts that were screened based on eligibility criteria resulting in 184 full-text articles with 630 reported cases of childhood MAS. Data extracted included patient characteristics, clinical presentation, vascular phenotype, management, and outcomes. Most cases of MAS are idiopathic (64%), 15% are associated with Mendelian disorders, and 17% are related to inflammatory diseases. Extra-aortic involvement including renal (70%), superior mesenteric (30%), and celiac (22%) arteries is common, especially among those with associated Mendelian disorders. Inferior mesenteric artery involvement is almost never reported. The majority of cases (72%) undergo endovascular or surgical management with residual hypertension reported in 34% of cases, requiring medication or reintervention. Clinical manifestations and extent of extra-aortic involvement are lacking. MAS presents with significant involvement of visceral arteries with over two thirds of cases having renal artery stenosis, and one third with superior mesenteric artery stenosis. The extent of disease is worse among those with genetic and inflammatory conditions. Further studies are needed to better understand etiology, long-term effectiveness of treatment, and to determine the optimal management of this potentially devastating condition. © American Journal of Hypertension, Ltd 2015. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Minoia, Francesca; Bovis, Francesca; Davì, Sergio; Insalaco, Antonella; Lehmberg, Kai; Shenoi, Susan; Weitzman, Sheila; Espada, Graciela; Gao, Yi-Jin; Anton, Jordi; Kitoh, Toshiyuki; Kasapcopur, Ozgur; Sanner, Helga; Merino, Rosa; Astigarraga, Itziar; Alessio, Maria; Jeng, Michael; Chasnyk, Vyacheslav; Nichols, Kim E; Huasong, Zeng; Li, Caifeng; Micalizzi, Concetta; Ruperto, Nicolino; Martini, Alberto; Cron, Randy Q; Ravelli, Angelo; Horne, AnnaCarin
2017-10-01
To develop and validate a diagnostic score that assists in discriminating primary hemophagocytic lymphohistiocytosis (pHLH) from macrophage activation syndrome (MAS) related to systemic juvenile idiopathic arthritis. The clinical, laboratory, and histopathologic features of 362 patients with MAS and 258 patients with pHLH were collected in a multinational collaborative study. Eighty percent of the population was assessed to develop the score and the remaining 20% constituted the validation sample. Variables that entered the best fitted model of logistic regression were assigned a score, based on their statistical weight. The MAS/HLH (MH) score was made up with the individual scores of selected variables. The cutoff in the MH score that discriminated pHLH from MAS best was calculated by means of receiver operating characteristic curve analysis. Score performance was examined in both developmental and validation samples. Six variables composed the MH score: age at onset, neutrophil count, fibrinogen, splenomegaly, platelet count, and hemoglobin. The MH score ranged from 0 to 123, and its median value was 97 (1st-3rd quartile 75-123) and 12 (1st-3rd quartile 11-34) in pHLH and MAS, respectively. The probability of a diagnosis of pHLH ranged from <1% for a score of <11 to >99% for a score of ≥123. A cutoff value of ≥60 revealed the best performance in discriminating pHLH from MAS. The MH score is a powerful tool that may aid practitioners to identify patients who are more likely to have pHLH and, thus, could be prioritized for functional and genetic testing. Copyright © 2017 Elsevier Inc. All rights reserved.
Reis, Augusto B; Araújo, Fabiano C; Pereira, Virginia M; Dos Reis, Adelina M; Santos, Robson A; Reis, Fernando M
2010-02-01
The presence of classical components of the renin-angiotensin system has been demonstrated in the male reproductive tract, mainly in the testes and epididymis. The objective of this study was to verify the localization of angiotensin (Ang)-(1-7) and its receptor Mas in human testis. The study included 12 men with previously proven fertility submitted to orchiectomy for prostate cancer and 20 infertile men submitted to testicular biopsy for infertility work-up, comprising a subgroup with obstructive azoospermia/normal spermatogenesis (n = 8) and another with non-obstructive azoospermia and severely impaired spermatogenesis (n = 12). Testicular tissue samples were processed by immunohistochemistry and real time polymerase chain reaction. Ang-(1-7) was strongly expressed in the interstitial compartment, mainly in Leydig cells, with similar intensity in all groups evaluated. The peptide was also detected in the seminiferous tubules, but with much less intensity compared to interstitial cells. The receptor Mas was equally distributed between interstitial and tubular compartments and was found in all layers of the normal seminiferous epithelium. However, neither Ang-(1-7) nor Mas were detected in the seminiferous tubules of samples with impaired spermatogenesis. The testicular samples of infertile men with impaired spermatogenesis (non-obstructive azoospermia) expressed Mas and ACE2 mRNA at lower concentrations (fold change = 0.06 and 0.04, respectively, P < 0.05) than samples with full spermatogenesis (obstructive azoospermia). This shows, for the first time, the immunolocalization of Ang-(1-7) and its receptor Mas in testes of fertile and infertile men, and suggests that this system may be altered when spermatogenesis is severely impaired.
The Mas receptor mediates modulation of insulin signaling by angiotensin-(1-7).
Muñoz, Marina C; Giani, Jorge F; Burghi, Valeria; Mayer, Marcos A; Carranza, Andrea; Taira, Carlos A; Dominici, Fernando P
2012-08-20
Angiotensin (Ang)-(1-7) stimulates proteins belonging to the insulin signaling pathway and ameliorates the Ang II negative effects at this level. However, up to date, receptors involved and mechanisms behind these observations remain unknown. Accordingly, in the present study, we explored the in vivo effects of antagonism of the Ang-(1-7) specific Mas receptor on insulin signal transduction in rat insulin-target tissues. We evaluated the acute modulation of insulin-stimulated phosphorylation of Akt, GSK-3β (Glycogen synthase kinase-3β) and AS160 (Akt substrate of 160kDa) by Ang-(1-7) and/or Ang II in the presence and absence of the selective Mas receptor antagonist A-779 in insulin-target tissues of normal rats. Also using A-779, we determined whether the Mas receptor mediates the improvement of insulin sensitivity exerted by chronic Ang-(1-7) treatment in fructose-fed rats (FFR), a model of insulin resistance, dyslipidemia and mild hypertension. The two major findings of the present work are as follows; 1) Ang-(1-7) attenuates acute Ang II-mediated inhibition of insulin signaling components in normal rats via a Mas receptor-dependent mechanism; and 2). The Mas receptor appears to be involved in beneficial effects of Ang-(1-7) on the phosphorylation of crucial insulin signaling mediators (Akt, GSK-3β and AS160), in liver, skeletal muscle and adipose tissue of FFR. These results shed light into the mechanism by which Ang-(1-7) exerts its positive physiological modulation of insulin actions in classical metabolic tissues and reinforces the central role of Akt in these effects. Copyright © 2012 Elsevier B.V. All rights reserved.
Comparison of HR MAS MR spectroscopic profiles of breast cancer tissue with clinical parameters.
Sitter, Beathe; Lundgren, Steinar; Bathen, Tone F; Halgunset, Jostein; Fjosne, Hans E; Gribbestad, Ingrid S
2006-02-01
Breast cancer is the most frequent form of cancer in women and improved diagnostic methods are desirable. Malignant cells have altered metabolism and metabolic mapping might become a tool in cancer diagnostics. High-resolution magic angle spinning (HR MAS) MR spectroscopy of tissue biopsies provides detailed information on metabolic composition. The 600 MHz 1H HR MAS spectra were acquired of breast cancer tissue from 85 patients and adjacent non-involved tissue from 18 of these patients. Tissue specimens were investigated by microscopy after MR analysis. The resulting spectra were examined by three different approaches. Relative intensities of glycerophosphocholine (GPC), phosphocholine (PC) and choline were compared for cancerous and non-involved specimens. Eight metabolites, choline, creatine, beta-glucose, GPC, glycine, myo-inositol, PC and taurine, were quantified from the recorded spectra and compared with tumor histological type and size, patient's lymph node status and tissue composition of sample. The spectra were also compared with tumor histological type and size, lymph node status and tissue composition of samples using principal component analysis (PCA). Tumor samples could be distinguished from non-involved samples (82% sensitivity, 100% specificity) based on relative intensities of signals from GPC, PC and choline in 1H HR MAS spectra. Tissue concentrations of metabolites showed few differences between groups of samples, which can be caused by limitations in the quantification procedure. Choline and glycine concentrations were found to be significantly higher in tumors larger than 2 cm compared with smaller tumors. PCA of MAS spectra from patients with invasive ductal carcinomas indicated a possible prediction of spread to axillary lymph nodes. Metabolite estimates and PCA of MAS spectra were influenced by the percentage of tumor cells in the investigated specimens. 2006 John Wiley & Sons, Ltd.
Pulsed field gradient magic angle spinning NMR self-diffusion measurements in liquids
NASA Astrophysics Data System (ADS)
Viel, Stéphane; Ziarelli, Fabio; Pagès, Guilhem; Carrara, Caroline; Caldarelli, Stefano
2008-01-01
Several investigations have recently reported the combined use of pulsed field gradient (PFG) with magic angle spinning (MAS) for the analysis of molecular mobility in heterogeneous materials. In contrast, little attention has been devoted so far to delimiting the role of the extra force field induced by sample rotation on the significance and reliability of self-diffusivity measurements. The main purpose of this work is to examine this phenomenon by focusing on pure liquids for which its impact is expected to be largest. Specifically, we show that self-diffusion coefficients can be accurately determined by PFG MAS NMR diffusion measurements in liquids, provided that specific experimental conditions are met. First, the methodology to estimate the gradient uniformity and to properly calibrate its absolute strength is briefly reviewed and applied on a MAS probe equipped with a gradient coil aligned along the rotor spinning axis, the so-called 'magic angle gradient' coil. Second, the influence of MAS on the outcome of PFG MAS diffusion measurements in liquids is investigated for two distinct typical rotors of different active volumes, 12 and 50 μL. While the latter rotor led to totally unreliable results, especially for low viscosity compounds, the former allowed for the determination of accurate self-diffusion coefficients both for fast and slowly diffusing species. Potential implications of this work are the possibility to measure accurate self-diffusion coefficients of sample-limited mixtures or to avoid radiation damping interferences in NMR diffusion measurements. Overall, the outlined methodology should be of interest to anyone who strives to improve the reliability of MAS diffusion studies, both in homogeneous and heterogeneous media.
Bixby, Miriam; Baylis, Kathy; Hoover, Shelley E; Currie, Rob W; Melathopoulos, Andony P; Pernal, Stephen F; Foster, Leonard J; Guarna, M Marta
2017-06-01
Over the past decade in North America and Europe, winter losses of honey bee (Hymenoptera: Apidae) colonies have increased dramatically. Scientific consensus attributes these losses to multifactorial causes including altered parasite and pathogen profiles, lack of proper nutrition due to agricultural monocultures, exposure to pesticides, management, and weather. One method to reduce colony loss and increase productivity is through selective breeding of queens to produce disease-, pathogen-, and mite-resistant stock. Historically, the only method for identifying desirable traits in honey bees to improve breeding was through observation of bee behavior. A team of Canadian scientists have recently identified markers in bee antennae that correspond to behavioral traits in bees and can be tested for in a laboratory. These scientists have demonstrated that this marker-assisted selection (MAS) can be used to produce hygienic, pathogen-resistant honey bee colonies. Based on this research, we present a beekeeping case study where a beekeeper's profit function is used to evaluate the economic impact of adopting colonies selected for hygienic behavior using MAS into an apiary. Our results show a net profit gain from an MAS colony of between 2% and 5% when Varroa mites are effectively treated. In the case of ineffective treatment, MAS generates a net profit benefit of between 9% and 96% depending on the Varroa load. When a Varroa mite population has developed some treatment resistance, we show that MAS colonies generate a net profit gain of between 8% and 112% depending on the Varroa load and degree of treatment resistance. © The Authors 2017. Published by Oxford University Press on behalf of Entomological Society of America.
Li, Yonghong; Cai, Shanglang; Wang, Qixin; Zhou, Jingwei; Hou, Bo; Yu, Haichu; Ge, Zhiming; Guan, Renyan; Liu, Xu
2016-05-15
The role of the Mas receptor in the activity of valsartan against intimal hyperplasia is unclear. Herein, we investigated the role of the angiotensin-converting enzyme 2 (ACE2)-angiotensin-(1-7)-Mas receptor axis on the activity of valsartan against intimal hyperplasiain balloon-injured rat aortic arteries. Wistar rats were randomized equally into the sham control group, injured group, and injured plus valsartan (20 mg/kg/d)-treated group. Valsartan significantly attenuated the vascular smooth muscle cell proliferation and intimal and medial thickening on days 14 and 28 after injury. The angiotensin-(1-7) levels as well as ACE2 and Mas receptor mRNA/protein expression were significantly decreased in the injured rats, compared to the uninjured rats; meanwhile, the angiotensin II level as well as the ACE and AT1 receptor mRNA/protein expression were increased (all P < 0.05 or < 0.01). Additionally, the p-ERK protein expression was increased (P < 0.01). Treatment with valsartan significantly increased the angiotensin-(1-7) levels as well as ACE2 and Mas receptor mRNA/protein expression but decreased the angiotensin II level, ACE and AT1 receptor mRNA/protein expression, as well as the p-ERK protein expression, compared to the injured group (all P < 0.05 or < 0.01). These results suggest that valsartan attenuates neointimal hyperplasiain balloon-injured rat aortic arteries through activation of the ACE2-angiotensin-(1-7)-Mas axis as well as inhibition of the ACE-angiotensin II-AT1 and p-ERK pathways. Copyright © 2016 Elsevier Inc. All rights reserved.
Eclipses of the inner satellites of Jupiter observed in 2015
NASA Astrophysics Data System (ADS)
Saquet, E.; Emelyanov, N.; Colas, F.; Arlot, J.-E.; Robert, V.; Christophe, B.; Dechambre, O.
2016-06-01
Aims: During the 2014-2015 campaign of mutual events, we recorded ground-based photometric observations of eclipses of Amalthea (JV) and, for the first time, Thebe (JXIV) by the Galilean moons. We focused on estimating whether the positioning accuracy of the inner satellites determined with photometry is sufficient for dynamical studies. Methods: We observed two eclipses of Amalthea and one of Thebe with the 1 m telescope at Pic du Midi Observatory using an IR filter and a mask placed over the planetary image to avoid blooming features. A third observation of Amalthea was taken at Saint-Sulpice Observatory with a 60 cm telescope using a methane filter (890 nm) and a deep absorption band to decrease the contrast between the planet and the satellites. After background removal, we computed a differential aperture photometry to obtain the light flux, and followed with an astrometric reduction. Results: We provide astrometric results with an external precision of 53 mas for the eclipse of Thebe, and 20 mas for that of Amalthea. These observation accuracies largely override standard astrometric measurements. The (O - C)s for the eclipse of Thebe are 75 mas on the X-axis and 120 mas on the Y-axis. The (O - C)s for the total eclipses of Amalthea are 95 mas and 22 mas, along the orbit, for two of the three events. Taking into account the ratio of (O - C) to precision of the astrometric results, we show a significant discrepancy with the theory established by Avdyushev and Ban'shikova in 2008, and the JPL JUP 310 ephemeris. Three of the four eclipse observations where recorded at the 1 m telescope of Pic du Midi Observatory (S2P), the other at Saint-Sulpice Observatory.
NASA Astrophysics Data System (ADS)
Ananthanarayanan, A.; Kothiyal, G. P.; Montagne, L.; Revel, B.
2010-06-01
Lithium aluminum silicate (LAS) glass of composition (mol%) 20.4Li 2O-4.0Al 2O 3-68.6SiO 2-3.0K 2O-2.6B 2O 3-0.5P 2O 5-0.9TiO 2 was prepared by melt quenching. The glass was then nucleated and crystallized based on differential thermal analysis (DTA) data and was characterized by 29Si, 31P, 11B and 27Al MAS-NMR. XRD and 29Si NMR showed that lithium metasilicate (Li 2SiO 3) is the first phase to c form followed by cristobalite (SiO 2) and lithium disilicate (Li 2Si 2O 5). 29Si MAS-NMR revealed a change in the network structure already for the glasses nucleated at 550 °C. Since crystalline Li 3PO 4, as observed by 31P MAS-NMR, forms concurrently with the silicate phases, we conclude that crystalline Li 3PO 4 does not act as a nucleating agent for lithium silicate phases. Moreover, 31P NMR indicates the formation of M-PO 4 ( M=B, Al or Ti) complexes. The presence of BO 3 and BO 4 structural units in all the glass/glass-ceramic samples is revealed through 11B MAS-NMR. B remains in the residual glass and the crystallization of silicate phases causes a reduction in the number of alkali ions available for charge compensation. As a result, the number of trigonally coordinated B (BO 3) increases at the expense of tetrahedrally coordinated B (BO 4). The 27Al MAS-NMR spectra indicate the presence of tetrahedrally coordinated Al species, which are only slightly perturbed by the crystallization.
Valenzuela, Olga L.; Borja-Aburto, Victor H.; Garcia-Vargas, Gonzalo G.; Cruz-Gonzalez, Martha B.; Garcia-Montalvo, Eliud A.; Calderon-Aranda, Emma S.; Del Razo, Luz M.
2005-01-01
Chronic exposure to inorganic arsenic (iAs) has been associated with increased risk of various forms of cancer and of noncancerous diseases. Metabolic conversions of iAs that yield highly toxic and genotoxic methylarsonite (MAsIII) and dimethylarsinite (DMAsIII) may play a significant role in determining the extent and character of toxic and cancer-promoting effects of iAs exposure. In this study we examined the relationship between urinary profiles of MAsIII and DMAsIII and skin lesion markers of iAs toxicity in individuals exposed to iAs in drinking water. The study subjects were recruited among the residents of an endemic region of central Mexico. Drinking-water reservoirs in this region are heavily contaminated with iAs. Previous studies carried out in the local populations have found an increased incidence of pathologies, primarily skin lesions, that are characteristic of arseniasis. The goal of this study was to investigate the urinary profiles for the trivalent and pentavalent As metabolites in both high- and low-iAs–exposed subjects. Notably, methylated trivalent arsenicals were detected in 98% of analyzed urine samples. On average, the major metabolite, DMAsIII, represented 49% of total urinary As, followed by DMAsV (23.7%), iAsV (8.6%), iAsIII (8.5%), MAsIII (7.4%), and MAsV (2.8%). More important, the average MAsIII concentration was significantly higher in the urine of exposed individuals with skin lesions compared with those who drank iAs-contaminated water but had no skin lesions. These data suggest that urinary levels of MAsIII, the most toxic species among identified metabolites of iAs, may serve as an indicator to identify individuals with increased susceptibility to toxic and cancer-promoting effects of arseniasis. PMID:15743710
Multi-Agent Systems Design for Novices
ERIC Educational Resources Information Center
Lynch, Simon; Rajendran, Keerthi
2005-01-01
Advanced approaches to the construction of software systems can present difficulties to learners. This is true for multi-agent systems (MAS) which exhibit concurrency, non-determinacy of structure and composition and sometimes emergent behavior characteristics. Additional barriers exist for learners because mainstream MAS technology is young and…
MASTER ANALYTICAL SCHEME FOR ORGANIC COMPOUNDS IN WATER: PART 1. PROTOCOLS
A Master Analytical Scheme (MAS) has been developed for the analysis of volatile (gas chromatographable) organic compounds in water. In developing the MAS, it was necessary to evaluate and modify existing analysis procedures and develop new techniques to produce protocols that pr...
Biomolecular solid state NMR with magic-angle spinning at 25K.
Thurber, Kent R; Tycko, Robert
2008-12-01
A magic-angle spinning (MAS) probe has been constructed which allows the sample to be cooled with helium, while the MAS bearing and drive gases are nitrogen. The sample can be cooled to 25K using roughly 3 L/h of liquid helium, while the 4-mm diameter rotor spins at 6.7 kHz with good stability (+/-5 Hz) for many hours. Proton decoupling fields up to at least 130 kHz can be applied. This helium-cooled MAS probe enables a variety of one-dimensional and two-dimensional NMR experiments on biomolecular solids and other materials at low temperatures, with signal-to-noise proportional to 1/T. We show examples of low-temperature (13)C NMR data for two biomolecular samples, namely the peptide Abeta(14-23) in the form of amyloid fibrils and the protein HP35 in frozen glycerol/water solution. Issues related to temperature calibration, spin-lattice relaxation at low temperatures, paramagnetic doping of frozen solutions, and (13)C MAS NMR linewidths are discussed.
Diserens, Gaëlle; Vermathen, Martina; Gjuroski, Ilche; Eggimann, Sandra; Precht, Christina; Boesch, Chris; Vermathen, Peter
2016-08-01
The study aim was to unambiguously assign nucleotide sugars, mainly UDP-X that are known to be important in glycosylation processes as sugar donors, and glucose-phosphates that are important intermediate metabolites for storage and transfer of energy directly in spectra of intact cells, as well as in skeletal muscle biopsies by (1)H high-resolution magic-angle-spinning (HR-MAS) NMR. The results demonstrate that sugar phosphates can be determined quickly and non-destructively in cells and biopsies by HR-MAS, which may prove valuable considering the importance of phosphate sugars in cell metabolism for nucleic acid synthesis. As proof of principle, an example of phosphate-sugar reaction and degradation kinetics after unfreezing the sample is shown for a cardiac muscle, suggesting the possibility to follow by HR-MAS NMR some metabolic pathways. Graphical abstract Glucose-phosphate sugars (Glc-1P and Glc-6P) detected in muscle by 1H HR-MAS NMR.
Castiblanco, John; Sarmiento-Monroy, Juan Camilo; Mantilla, Ruben Dario; Rojas-Villarraga, Adriana; Anaya, Juan-Manuel
2015-01-01
Studies documenting increased risk of developing autoimmune diseases (ADs) have shown that these conditions share several immunogenetic mechanisms (i.e., the autoimmune tautology). This report explored familial aggregation and segregation of AD, polyautoimmunity, and multiple autoimmune syndrome (MAS) in 210 families. Familial aggregation was examined for first-degree relatives. Segregation analysis was implemented as in S.A.G.E. release 6.3. Data showed differences between late- and early-onset families regarding their age, age of onset, and sex. Familial aggregation of AD in late- and early-onset families was observed. For polyautoimmunity as a trait, only aggregation was observed between sibling pairs in late-onset families. No aggregation was observed for MAS. Segregation analyses for AD suggested major gene(s) with no clear discernible classical known Mendelian transmission in late-onset families, while for polyautoimmunity and MAS no model was implied. Data suggest that polyautoimmunity and MAS are not independent traits and that gender, age, and age of onset are interrelated factors influencing autoimmunity. PMID:26697508
Mallow Fiber-Reinforced Epoxy Composites in Multilayered Armor for Personal Ballistic Protection
NASA Astrophysics Data System (ADS)
Nascimento, Lucio Fábio Cassiano; Louro, Luis Henrique Leme; Monteiro, Sergio Neves; Lima, Édio Pereira; da Luz, Fernanda Santos
2017-10-01
Lighter and less expensive polymer composites reinforced with natural fibers have been investigated as possible components of a multilayered armor system (MAS) for personal protection against high-velocity ammunition. Their ballistic performance was consistently found comparable with that of conventional Kevlar® synthetic aramid fiber. Among the numerous existing natural fibers with the potential for reinforcing polymer composites to replace Kevlar® in MAS, mallow fiber has not been fully investigated. Thus, the objective of this work is to evaluate the ballistic performance of epoxy composites reinforced with 30 vol.% of aligned mallow fibers as a second MAS layer backing a front ceramic plate. The results using high-velocity 7.62 ammunition show a similar indentation to a Kevlar® layer with the same thickness. An impedance matching calculation supports the similar ballistic performance of mallow fiber composite and Kevlar®. Reduced MAS costs associated with the mallow fiber composite are practical advantages over Kevlar®.
Genomic deletion of CNGB3 is identical by descent in multiple canine breeds and causes achromatopsia
2013-01-01
Background Achromatopsia is an autosomal recessive disease characterized by the loss of cone photoreceptor function that results in day-blindness, total colorblindness, and decreased central visual acuity. The most common causes for the disease are mutations in the CNGB3 gene, coding for the beta subunit of the cyclic nucleotide-gated channels in cones. CNGB3-achromatopsia, or cone degeneration (cd), is also known to occur in two canine breeds, the Alaskan malamute (AM) and the German shorthaired pointer. Results Here we report an in-depth characterization of the achromatopsia phenotype in a new canine breed, the miniature Australian shepherd (MAS). Genotyping revealed that the dog was homozygous for a complete genomic deletion of the CNGB3 gene, as has been previously observed in the AM. Identical breakpoints on chromosome 29 were identified in both the affected AM and MAS with a resulting deletion of 404,820 bp. Pooled DNA samples of unrelated purebred Australian shepherd, MAS, Siberian husky, Samoyed and Alaskan sled dogs were screened for the presence of the affected allele; one Siberian husky and three Alaskan sled dogs were identified as carriers. The affected chromosomes from the AM, MAS, and Siberian husky were genotyped for 147 SNPs in a 3.93 Mb interval within the cd locus. An identical shared affected haplotype, 0.5 Mb long, was observed in all three breeds and defined the minimal linkage disequilibrium (LD) across breeds. This supports the idea that the mutated allele was identical by descent (IBD). Conclusion We report the occurrence of CNGB3-achromatopsia in a new canine breed, the MAS. The CNGB3-deletion allele previously described in the AM was also observed in a homozygous state in the affected MAS, as well as in a heterozygous carrier state in a Siberian husky and Alaskan sled dogs. All affected alleles were shown to be IBD, strongly suggesting an affected founder effect. Since the MAS is not known to be genetically related to the AM, other breeds may potentially carry the same cd-allele and be affected by achromatopsia. PMID:23601474
Using Third Party Data to Update a Reference Dataset in a Quality Evaluation Service
NASA Astrophysics Data System (ADS)
Xavier, E. M. A.; Ariza-López, F. J.; Ureña-Cámara, M. A.
2016-06-01
Nowadays it is easy to find many data sources for various regions around the globe. In this 'data overload' scenario there are few, if any, information available about the quality of these data sources. In order to easily provide these data quality information we presented the architecture of a web service for the automation of quality control of spatial datasets running over a Web Processing Service (WPS). For quality procedures that require an external reference dataset, like positional accuracy or completeness, the architecture permits using a reference dataset. However, this reference dataset is not ageless, since it suffers the natural time degradation inherent to geospatial features. In order to mitigate this problem we propose the Time Degradation & Updating Module which intends to apply assessed data as a tool to maintain the reference database updated. The main idea is to utilize datasets sent to the quality evaluation service as a source of 'candidate data elements' for the updating of the reference database. After the evaluation, if some elements of a candidate dataset reach a determined quality level, they can be used as input data to improve the current reference database. In this work we present the first design of the Time Degradation & Updating Module. We believe that the outcomes can be applied in the search of a full-automatic on-line quality evaluation platform.
Zhang, Hui-min; Tang, Qiang
2011-06-01
To explore the impacts of acupuncture and rehabilitation on post-stroke abnormal patterns of limb movement and evaluate them via rehabilitation method. Ninety cases of post-stroke movement disorder were randomly divided into an acupuncture-rehabilitation group, a body acupuncture group and a medication group, 30 cases in each group. In medication group, the conventional medication in neurological department was administered. In acupuncture-rehabilitation group and body acupuncture group, on the basis of the therapy as medication group, scalp acupuncture (such as parietal area and anterior parietal area, etc.), rehabilitation training and traditional body acupuncture [such as Jianyu (LI 15) and Fengshi (GB 31),etc.] were supplemented. The continuous electric stimulation was applied in body acupuncture group. The treatment lasted for 8 weeks. The assessment of clinical efficacy, Fugl-Meyer score, Modified Ashworth scale (MAS), range of motion (ROM) and shoulder pain score were taken as observation indices for rehabilitation evaluation before and after treatment in each group. The effective rate was 93.1% (27/29) in acupuncture-rehabilitation group, which was superior to 66.7% (20/30) in body acupuncture group and 57.1% (16/28) in control group (both P<0.01) separately. After treatment, Fugl-Meyer score, MAS, ROM of the lower limbs and shoulder joint and shoulder pain score (except medication group) were all remarkably improved as compared with those before treatment in each group (all P<0.01). The improvements in Fugl-Meyer score, MAS, ROM of the upper limbs and shoulder pain score in acupuncture-rehabilitation group were significantly superior to those in body acupuncture group and medication group (P<0.05, P<0.01). Acupuncture and rehabilitation therapy and traditional body acupuncture remarkably improve in post-stroke movement disorder. But acupuncture and rehabilitation therapy is apparently superior to traditional body acupuncture. This therapy can effectively prevent and treat post-stroke abnormal patterns and it is greatly significant in the improvement of survival quality for the patients.
Meta-QTL for resistance to white mold in common bean
Vasconcellos, Renato C. C.; Oraguzie, O. Blessing; Soler, Alvaro; Arkwazee, Haidar; Myers, James R.; Ferreira, Juan J.; Song, Qijian; McClean, Phil; Miklas, Phillip N.
2017-01-01
White mold, caused by the fungus Sclerotinia sclerotiorum (Lib.) de Bary, is a major disease that limits common bean production and quality worldwide. The host-pathogen interaction is complex, with partial resistance in the host inherited as a quantitative trait with low to moderate heritability. Our objective was to identify meta-QTL conditioning partial resistance to white mold from individual QTL identified across multiple populations and environments. The physical positions for 37 individual QTL were identified across 14 recombinant inbred bi-parental populations (six new, three re-genotyped, and five from the literature). A meta-QTL analysis of the 37 QTL was conducted using the genetic linkage map of Stampede x Red Hawk population as the reference. The 37 QTL condensed into 17 named loci (12 previously named and five new) of which nine were defined as meta-QTL WM1.1, WM2.2, WM3.1, WM5.4, WM6.2, WM7.1, WM7.4, WM7.5, and WM8.3. The nine meta-QTL had confidence intervals ranging from 0.65 to 9.41 Mb. Candidate genes shown to express under S. sclerotiorum infection in other studies, including cell wall receptor kinase, COI1, ethylene responsive transcription factor, peroxidase, and MYB transcription factor, were found within the confidence interval for five of the meta-QTL. The nine meta-QTL are recommended as potential targets for MAS for partial resistance to white mold in common bean. PMID:28199342
MASTER ANALYTICAL SCHEME FOR ORGANIC COMPOUNDS IN WATER. PART 2. APPENDICES TO PROTOCOLS
A Master Analytical Scheme (MAS) has been developed for the analysis of volatile (gas chromatographable) organic compounds in water. In developing the MAS, it was necessary to evaluate and modify existing analysis procedures and develop new techniques to produce protocols that pr...
Golden, Sean K; Harringa, John B; Pickhardt, Perry J; Ebinger, Alexander; Svenson, James E; Zhao, Ying-Qi; Li, Zhanhai; Westergaard, Ryan P; Ehlenbach, William J; Repplinger, Michael D
2016-07-01
To determine whether clinical scoring systems or physician gestalt can obviate the need for computed tomography (CT) in patients with possible appendicitis. Prospective, observational study of patients with abdominal pain at an academic emergency department (ED) from February 2012 to February 2014. Patients over 11 years old who had a CT ordered for possible appendicitis were eligible. All parameters needed to calculate the scores were recorded on standardised forms prior to CT. Physicians also estimated the likelihood of appendicitis. Test characteristics were calculated using clinical follow-up as the reference standard. Receiver operating characteristic curves were drawn. Of the 287 patients (mean age (range), 31 (12-88) years; 60% women), the prevalence of appendicitis was 33%. The Alvarado score had a positive likelihood ratio (LR(+)) (95% CI) of 2.2 (1.7 to 3) and a negative likelihood ratio (LR(-)) of 0.6 (0.4 to 0.7). The modified Alvarado score (MAS) had LR(+) 2.4 (1.6 to 3.4) and LR(-) 0.7 (0.6 to 0.8). The Raja Isteri Pengiran Anak Saleha Appendicitis (RIPASA) score had LR(+) 1.3 (1.1 to 1.5) and LR(-) 0.5 (0.4 to 0.8). Physician-determined likelihood of appendicitis had LR(+) 1.3 (1.2 to 1.5) and LR(-) 0.3 (0.2 to 0.6). When combined with physician likelihoods, LR(+) and LR(-) was 3.67 and 0.48 (Alvarado), 2.33 and 0.45 (RIPASA), and 3.87 and 0.47 (MAS). The area under the curve was highest for physician-determined likelihood (0.72), but was not statistically significantly different from the clinical scores (RIPASA 0.67, Alvarado 0.72, MAS 0.7). Clinical scoring systems performed equally well as physician gestalt in predicting appendicitis. These scores do not obviate the need for imaging for possible appendicitis when a physician deems it necessary. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Kalapsazova, M; Ivanova, S; Kukeva, R; Simova, S; Wegner, S; Zhecheva, E; Stoyanova, R
2017-10-11
Knowledge on the formation of mixed transition metal layers on lithium and sodium transition metal oxides, Li/Na(Co,Ni,Mn,)O 2 , determines the ability to control their electrochemical properties as electrode materials in alkaline ion batteries. Taking this into account, herein we combine the EPR and 23 Na MAS NMR spectroscopic techniques to gain insights into the structural peculiarities of the mixed cobalt-nickel-manganese layers of Na y Co 1-2x Ni x Mn x O 2 with a three-layer stacking (P3-type) structure. Two types of compositions are examined where diamagnetic Co 3+ and paramagnetic Ni 3+ and Mn 4+ are stabilized: Na 2/3 Co 1/3 Ni 1/3 Mn 1/3 O 2 and Na 1/2 Ni 1/2 Mn 1/2 O 2 . EPR spectroscopy operating in the X- and Q-band region is applied with an aim to improve the spectra resolution and, on the other hand, to provide straightforward information on the coordination of the transition metal ions inside the layers. The analysis of EPR spectra is based on the reference for the Mn 4+ and Ni 2+ ions occurring simultaneously in oxides with two layer stacking, P2-Na 2/3 Ni 1/3 Mn 2/3 O 2 . Complementary to EPR, 23 Na MAS NMR spectroscopy at high spinning rates is undertaken to assess the local structure of the Na nucleus in the layered P3-Na y Co 1-2x Ni x Mn x O 2 oxides. All results are discussed taking into account the EPR and NMR data for the well-known lithium analogues O3-LiCo 1/3 Ni 1/3 Mn 1/3 O 2 and O3-LiNi 1/2 Mn 1/2 O 2 . Finally, the structure peculiarities of the transition metal layers extracted from the EPR and NMR methods are demonstrated by electrochemical intercalation of Li + ions into P3-Na y Co 1-2x Ni x Mn x O 2 .
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rong Yi, E-mail: rong@humonc.wisc.ed; Smilowitz, Jennifer; Tewatia, Dinesh
2010-10-01
Precise calibration of Hounsfield units (HU) to electron density (HU-density) is essential to dose calculation. On-board kV cone beam computed tomography (CBCT) imaging is used predominantly for patients' positioning, but will potentially be used for dose calculation. The impacts of varying 3 imaging parameters (mAs, source-imager distance [SID], and cone angle) and phantom size on the HU number accuracy and HU-density calibrations for CBCT imaging were studied. We proposed a site-specific calibration method to achieve higher accuracy in CBCT image-based dose calculation. Three configurations of the Computerized Imaging Reference Systems (CIRS) water equivalent electron density phantom were used to simulatemore » sites including head, lungs, and lower body (abdomen/pelvis). The planning computed tomography (CT) scan was used as the baseline for comparisons. CBCT scans of these phantom configurations were performed using Varian Trilogy{sup TM} system in a precalibrated mode with fixed tube voltage (125 kVp), but varied mAs, SID, and cone angle. An HU-density curve was generated and evaluated for each set of scan parameters. Three HU-density tables generated using different phantom configurations with the same imaging parameter settings were selected for dose calculation on CBCT images for an accuracy comparison. Changing mAs or SID had small impact on HU numbers. For adipose tissue, the HU discrepancy from the baseline was 20 HU in a small phantom, but 5 times lager in a large phantom. Yet, reducing the cone angle significantly decreases the HU discrepancy. The HU-density table was also affected accordingly. By performing dose comparison between CT and CBCT image-based plans, results showed that using the site-specific HU-density tables to calibrate CBCT images of different sites improves the dose accuracy to {approx}2%. Our phantom study showed that CBCT imaging can be a feasible option for dose computation in adaptive radiotherapy approach if the site-specific calibration is applied.« less
Final Report on Two-Stage Fast Spectrum Fuel Cycle Options
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Won Sik; Lin, C. S.; Hader, J. S.
2016-01-30
This report presents the performance characteristics of two “two-stage” fast spectrum fuel cycle options proposed to enhance uranium resource utilization and to reduce nuclear waste generation. One is a two-stage fast spectrum fuel cycle option of continuous recycle of plutonium (Pu) in a fast reactor (FR) and subsequent burning of minor actinides (MAs) in an accelerator-driven system (ADS). The first stage is a sodium-cooled FR fuel cycle starting with low-enriched uranium (LEU) fuel; at the equilibrium cycle, the FR is operated using the recovered Pu and natural uranium without supporting LEU. Pu and uranium (U) are co-extracted from the dischargedmore » fuel and recycled in the first stage, and the recovered MAs are sent to the second stage. The second stage is a sodium-cooled ADS in which MAs are burned in an inert matrix fuel form. The discharged fuel of ADS is reprocessed, and all the recovered heavy metals (HMs) are recycled into the ADS. The other is a two-stage FR/ADS fuel cycle option with MA targets loaded in the FR. The recovered MAs are not directly sent to ADS, but partially incinerated in the FR in order to reduce the amount of MAs to be sent to the ADS. This is a heterogeneous recycling option of transuranic (TRU) elements« less
Raju, Leo; Milton, R S; Mahadevan, Senthilkumaran
The objective of this paper is implementation of multiagent system (MAS) for the advanced distributed energy management and demand side management of a solar microgrid. Initially, Java agent development environment (JADE) frame work is used to implement MAS based dynamic energy management of solar microgrid. Due to unstable nature of MATLAB, when dealing with multithreading environment, MAS operating in JADE is linked with the MATLAB using a middle ware called Multiagent Control Using Simulink with Jade Extension (MACSimJX). MACSimJX allows the solar microgrid components designed with MATLAB to be controlled by the corresponding agents of MAS. The microgrid environment variables are captured through sensors and given to agents through MATLAB/Simulink and after the agent operations in JADE, the results are given to the actuators through MATLAB for the implementation of dynamic operation in solar microgrid. MAS operating in JADE maximizes operational efficiency of solar microgrid by decentralized approach and increase in runtime efficiency due to JADE. Autonomous demand side management is implemented for optimizing the power exchange between main grid and microgrid with intermittent nature of solar power, randomness of load, and variation of noncritical load and grid price. These dynamics are considered for every time step and complex environment simulation is designed to emulate the distributed microgrid operations and evaluate the impact of agent operations.
Raju, Leo; Milton, R. S.; Mahadevan, Senthilkumaran
2016-01-01
The objective of this paper is implementation of multiagent system (MAS) for the advanced distributed energy management and demand side management of a solar microgrid. Initially, Java agent development environment (JADE) frame work is used to implement MAS based dynamic energy management of solar microgrid. Due to unstable nature of MATLAB, when dealing with multithreading environment, MAS operating in JADE is linked with the MATLAB using a middle ware called Multiagent Control Using Simulink with Jade Extension (MACSimJX). MACSimJX allows the solar microgrid components designed with MATLAB to be controlled by the corresponding agents of MAS. The microgrid environment variables are captured through sensors and given to agents through MATLAB/Simulink and after the agent operations in JADE, the results are given to the actuators through MATLAB for the implementation of dynamic operation in solar microgrid. MAS operating in JADE maximizes operational efficiency of solar microgrid by decentralized approach and increase in runtime efficiency due to JADE. Autonomous demand side management is implemented for optimizing the power exchange between main grid and microgrid with intermittent nature of solar power, randomness of load, and variation of noncritical load and grid price. These dynamics are considered for every time step and complex environment simulation is designed to emulate the distributed microgrid operations and evaluate the impact of agent operations. PMID:27127802
A quantitative study on magnesium alloy stent biodegradation.
Gao, Yuanming; Wang, Lizhen; Gu, Xuenan; Chu, Zhaowei; Guo, Meng; Fan, Yubo
2018-06-06
Insufficient scaffolding time in the process of rapid corrosion is the main problem of magnesium alloy stent (MAS). Finite element method had been used to investigate corrosion of MAS. However, related researches mostly described all elements suffered corrosion in view of one-dimensional corrosion. Multi-dimensional corrosions significantly influence mechanical integrity of MAS structures such as edges and corners. In this study, the effects of multi-dimensional corrosion were studied using experiment quantitatively, then a phenomenological corrosion model was developed to consider these effects. We implemented immersion test with magnesium alloy (AZ31B) cubes, which had different numbers of exposed surfaces to analyze differences of dimension. It was indicated that corrosion rates of cubes are almost proportional to their exposed-surface numbers, especially when pitting corrosions are not marked. The cubes also represented the hexahedron elements in simulation. In conclusion, corrosion rate of every element accelerates by increasing corrosion-surface numbers in multi-dimensional corrosion. The damage ratios among elements with the same size are proportional to the ratios of corrosion-surface numbers under uniform corrosion. The finite element simulation using proposed model provided more details of changes of morphology and mechanics in scaffolding time by removing 25.7% of elements of MAS. The proposed corrosion model reflected the effects of multi-dimension on corrosions. It would be used to predict degradation process of MAS quantitatively. Copyright © 2018 Elsevier Ltd. All rights reserved.
A review of international pharmacy-based minor ailment services and proposed service design model.
Aly, Mariyam; García-Cárdenas, Victoria; Williams, Kylie; Benrimoj, Shalom I
2018-01-05
The need to consider sustainable healthcare solutions is essential. An innovative strategy used to promote minor ailment care is the utilisation of community pharmacists to deliver minor ailment services (MASs). Promoting higher levels of self-care can potentially reduce the strain on existing resources. To explore the features of international MASs, including their similarities and differences, and consider the essential elements to design a MAS model. A grey literature search strategy was completed in June 2017 to comply with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses standard. This included (1) Google/Yahoo! search engines, (2) targeted websites, and (3) contact with commissioning organisations. Executive summaries, table of contents and title pages of documents were reviewed. Key characteristics of MASs were extracted and a MAS model was developed. A total of 147 publications were included in the review. Key service elements identified included eligibility, accessibility, staff involvement, reimbursement systems. Several factors need to be considered when designing a MAS model; including contextualisation of MAS to the market. Stakeholder engagement, service planning, governance, implementation and review have emerged as key aspects involved with a design model. MASs differ in their structural parameters. Consideration of these parameters is necessary when devising MAS aims and assessing outcomes to promote sustainability and success of the service. Copyright © 2018 Elsevier Inc. All rights reserved.
Selb, Juliette; Yücel, Meryem A; Phillip, Dorte; Schytz, Henrik W; Iversen, Helle K; Vangel, Mark; Ashina, Messoud; Boas, David A
2015-05-01
Functional near-infrared spectroscopy is prone to contamination by motion artifacts (MAs). Motion correction algorithms have previously been proposed and their respective performance compared for evoked rain activation studies. We study instead the effect of MAs on "oscillation" data which is at the basis of functional connectivity and autoregulation studies. We use as our metric of interest the interhemispheric correlation (IHC), the correlation coefficient between symmetrical time series of oxyhemoglobin oscillations. We show that increased motion content results in a decreased IHC. Using a set of motion-free data on which we add real MAs, we find that the best motion correction approach consists of discarding the segments of MAs following a careful approach to minimize the contamination due to band-pass filtering of data from "bad" segments spreading into adjacent "good" segments. Finally, we compare the IHC in a stroke group and in a healthy group that we artificially contaminated with the MA content of the stroke group, in order to avoid the confounding effect of increased motion incidence in the stroke patients. After motion correction, the IHC remains lower in the stroke group in the frequency band around 0.1 and 0.04 Hz, suggesting a physiological origin for the difference. We emphasize the importance of considering MAs as a confounding factor in oscillation-based functional near-infrared spectroscopy studies.